WorldWideScience

Sample records for adc testing generators

  1. The test ability of an adaptive pulse wave for ADC testing

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.

    2010-01-01

    In the conventional ADC production test method, a high-quality analogue sine wave is applied to the Analogue-to-Digital Converter (ADC), which is expensive to generate. Nowadays, an increasing number of ADCs are integrated into a system-on-chip (SoC) platform design, which usually contains a digital

  2. Comparison of Absolute Apparent Diffusion Coefficient (ADC) Values in ADC Maps Generated Across Different Postprocessing Software: Reproducibility in Endometrial Carcinoma.

    Science.gov (United States)

    Ghosh, Adarsh; Singh, Tulika; Singla, Veenu; Bagga, Rashmi; Khandelwal, Niranjan

    2017-12-01

    Apparent diffusion coefficient (ADC) maps are usually generated by builtin software provided by the MRI scanner vendors; however, various open-source postprocessing software packages are available for image manipulation and parametric map generation. The purpose of this study is to establish the reproducibility of absolute ADC values obtained using different postprocessing software programs. DW images with three b values were obtained with a 1.5-T MRI scanner, and the trace images were obtained. ADC maps were automatically generated by the in-line software provided by the vendor during image generation and were also separately generated on postprocessing software. These ADC maps were compared on the basis of ROIs using paired t test, Bland-Altman plot, mountain plot, and Passing-Bablok regression plot. There was a statistically significant difference in the mean ADC values obtained from the different postprocessing software programs when the same baseline trace DW images were used for the ADC map generation. For using ADC values as a quantitative cutoff for histologic characterization of tissues, standardization of the postprocessing algorithm is essential across processing software packages, especially in view of the implementation of vendor-neutral archiving.

  3. ADC testing using digital stimuli

    NARCIS (Netherlands)

    Sheng, Xiaoqin

    2014-01-01

    The Analogue-to-Digital Converter (ADC) is one of the most typical and widely used mixed-signal circuits. They are applied in video, audio, high-speed communications systems and so on. Many ADCs are integrated into platform-based designs, the architecture which normally contains of standard blocks

  4. Corrected RMS Error and Effective Number of Bits for Sinewave ADC Tests

    International Nuclear Information System (INIS)

    Jerome J. Blair

    2002-01-01

    A new definition is proposed for the effective number of bits of an ADC. This definition removes the variation in the calculated effective bits when the amplitude and offset of the sinewave test signal is slightly varied. This variation is most pronounced when test signals with amplitudes of a small number of code bin widths are applied to very low noise ADC's. The effectiveness of the proposed definition is compared with that of other proposed definitions over a range of signal amplitudes and noise levels

  5. Reproducibility of brain ADC histograms

    International Nuclear Information System (INIS)

    Steens, S.C.A.; Buchem, M.A. van; Admiraal-Behloul, F.; Schaap, J.A.; Hoogenraad, F.G.C.; Wheeler-Kingshott, C.A.M.; Tofts, P.S.; Cessie, S. le

    2004-01-01

    The aim of this study was to assess the effect of differences in acquisition technique on whole-brain apparent diffusion coefficient (ADC) histogram parameters, as well as to assess scan-rescan reproducibility. Diffusion-weighted imaging (DWI) was performed in 7 healthy subjects with b-values 0-800, 0-1000, and 0-1500 s/mm 2 and fluid-attenuated inversion recovery (FLAIR) DWI with b-values 0-1000 s/mm 2 . All sequences were repeated with and without repositioning. The peak location, peak height, and mean ADC of the ADC histograms and mean ADC of a region of interest (ROI) in the white matter were compared using paired-sample t tests. Scan-rescan reproducibility was assessed using paired-sample t tests, and repeatability coefficients were reported. With increasing maximum b-values, ADC histograms shifted to lower values, with an increase in peak height (p<0.01). With FLAIR DWI, the ADC histogram shifted to lower values with a significantly higher, narrower peak (p<0.01), although the ROI mean ADC showed no significant differences. For scan-rescan reproducibility, no significant differences were observed. Different DWI pulse sequences give rise to different ADC histograms. With a given pulse sequence, however, ADC histogram analysis is a robust and reproducible technique. Using FLAIR DWI, the partial-voluming effect of cerebrospinal fluid, and thus its confounding effect on histogram analyses, can be reduced

  6. Diffusion-weighted (DW) MRI in lung cancers. ADC test-retest repeatability

    Energy Technology Data Exchange (ETDEWEB)

    Weller, Alex; Papoutsaki, Marianthi Vasiliki; Blackledge, Matthew; DeSouza, Nandita M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK Cancer Imaging Centre, Surrey (United Kingdom); Waterton, John C. [University of Manchester, Manchester (United Kingdom); Chiti, Arturo [Humanitas University, Milan (Italy); Stroobants, Sigrid [Universiteit Antwerpen, Antwerpen (Belgium); Kuijer, Joost [Vrije Universiteit Medisch Centrum, Amsterdam (Netherlands); Morgan, Veronica [Royal Marsden NHS Foundation Trust, Department of Medicine, London (United Kingdom)

    2017-11-15

    To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800 s/mm{sup -2}). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. Whole-tumour ADC values ranged from 0.66-1.94x10{sup -3} mm{sup 2}s{sup -1} (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R{sup 2} = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. (orig.)

  7. Conversion of ADC pulse heights into MIP units (NUMASS test data, September 1991)

    International Nuclear Information System (INIS)

    Zhang, Q.P.

    1993-04-01

    ADC calibration is an important part of the data analysis in particle physics. Data analysis of ADC pulse heights is based on a physical unit which is called MIP (most probable energy loss of Minimum Ionization Particles). This paper describes the ADC calibration work for the September 1991 NUMASS test data, which were produced at CERN at the SPS facility. The Vavilov function is used to fit the energy loss distributions of minimum ionizing particles traversing the time of flight scintillators embedded in the uranium scintillator calorimeter. It is assumed that the energy loss distribution is the same for identical scintillators and the value at the peak of these distributions is used, i.e., the most probable energy loss, as a physical unit to derive the gains of the individual readout channels

  8. Self-adapted sliding scale spectroscopy ADC

    International Nuclear Information System (INIS)

    Xu Qichun; Wang Jingjin

    1992-01-01

    The traditional sliding scale technique causes a disabled range that is equal to the sliding length, thus reduces the analysis range of a MCA. A method for reduce ADC's DNL, which is called self-adapted sliding scale method, has been designed and tested. With this method, the disabled range caused by a traditional sliding scale method can be eliminated by a random trial scale and there is no need of an additional amplitude discriminator with swing threshold. A special trial-and-correct logic is presented. The tested DNL of the spectroscopy ADC described here is less than 0.5%

  9. ADC Catalog Services: an Update

    Science.gov (United States)

    Gass, J. E.; Roman, N. G.; Schneider, G. L.; Blackwell, J. H.; Kuin, N. P. M.; Larkin, M. C.; Lyu, C.-C. J.; Cheung, C. Y.

    1996-12-01

    The Astronomical Data Center (ADC) at the NASA Goddard Space Flight Center is a major archive and distribution center for computer-readable versions of astronomical catalogs and journal data tables. The ADC's archives contain more than 1600 catalogs and tables of astrometry, photometry, spectroscopy, radio, high energy, and other miscellaneous data for stellar and non-stellar objects. These data files are documented in a standardized manner, developed in cooperation with the Centre de Donnees astronomiques de Strasbourg (CDS). The ADC's data collection is available via anonymous FTP from node adc.gsfc.nasa.gov in the /pub/adc/archives directory. The holdings can also be accessed from the ADC's WWW site, http://adc.gsfc.nasa.gov/. This site permits users to search the text of the documentation files to locate catalogs and tables of interest or to browse the archives. Hypertext author and keyword indices, and other browsing tools have recently been developed as additional aids to navigating the ADC's large collection of data sets. The ADC is currently developing services to allow researchers to easily locate data fields of interest within files in its archives. The ADC has also prepared three volumes of CD-ROMs that contain several hundred of the largest and most requested catalogs in both ASCII and FITS table formats.

  10. ADC histogram analysis for adrenal tumor histogram analysis of apparent diffusion coefficient in differentiating adrenal adenoma from pheochromocytoma.

    Science.gov (United States)

    Umanodan, Tomokazu; Fukukura, Yoshihiko; Kumagae, Yuichi; Shindo, Toshikazu; Nakajo, Masatoyo; Takumi, Koji; Nakajo, Masanori; Hakamada, Hiroto; Umanodan, Aya; Yoshiura, Takashi

    2017-04-01

    To determine the diagnostic performance of apparent diffusion coefficient (ADC) histogram analysis in diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiating adrenal adenoma from pheochromocytoma. We retrospectively evaluated 52 adrenal tumors (39 adenomas and 13 pheochromocytomas) in 47 patients (21 men, 26 women; mean age, 59.3 years; range, 16-86 years) who underwent DW 3.0T MRI. Histogram parameters of ADC (b-values of 0 and 200 [ADC 200 ], 0 and 400 [ADC 400 ], and 0 and 800 s/mm 2 [ADC 800 ])-mean, variance, coefficient of variation (CV), kurtosis, skewness, and entropy-were compared between adrenal adenomas and pheochromocytomas, using the Mann-Whitney U-test. Receiver operating characteristic (ROC) curves for the histogram parameters were generated to differentiate adrenal adenomas from pheochromocytomas. Sensitivity and specificity were calculated by using a threshold criterion that would maximize the average of sensitivity and specificity. Variance and CV of ADC 800 were significantly higher in pheochromocytomas than in adrenal adenomas (P histogram parameters for diagnosing adrenal adenomas (ADC 200 , 0.82; ADC 400 , 0.87; and ADC 800 , 0.92), with sensitivity of 84.6% and specificity of 84.6% (cutoff, ≤2.82) with ADC 200 ; sensitivity of 89.7% and specificity of 84.6% (cutoff, ≤2.77) with ADC 400 ; and sensitivity of 94.9% and specificity of 92.3% (cutoff, ≤2.67) with ADC 800 . ADC histogram analysis of DW MRI can help differentiate adrenal adenoma from pheochromocytoma. 3 J. Magn. Reson. Imaging 2017;45:1195-1203. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Cerebral and cerebellar ADC values during a migraine attack

    Energy Technology Data Exchange (ETDEWEB)

    Degirmenci, Bumin; Haktanir, Alpay; Albayrak, Ramazan; Acar, Murat [University of Kocatepe, Department of Radiology, Faculty of Medicine, Afyon (Turkey); Yaman, Mehmet [University of Kocatepe, Department of Neurology, Faculty of Medicine, Afyon (Turkey)

    2007-05-15

    We investigated the diffusion-weighted MRI changes, apparent diffusion coefficient (ADC) values, and conventional MRI findings in specific brain areas during migraine attacks in patients with and without aura. Included in the study were 22 patients (2 male, 20 female) aged between 17 and 49 years who were diagnosed as having migraine according to the diagnostic criteria of the International Headache Society. Also included in the study were 18 age- and sex-matched healthy volunteers. Hyperintense lesions were evaluated in conventional MR images. Heavily diffusion-weighted images, ADC maps, and segmented ADC maps generated for regional ADC (rADC) measurements, were also studied. ADC values from specific brain areas were used with appropriate region of interests (ROI). Migraine with aura was diagnosed in 13 patients and migraine without aura was diagnosed in 9 patients. A total of 23 hyperintense lesions within the periventricular white matter and deep white matter were detected in five patients (21.8%). All of these hyperintense lesions were seen in migraine patients with aura. In only one patient did a hyperintense lesion show an increased diffusion pattern on diffusion-weighted images and ADC maps. One hyperintense lesion was detected in the control group (5.5%). There was no significant difference in ADC values between the migraine and control groups. T2-weighted hyperintense lesions were significantly more frequent in migraine patients especially in those with aura than in the control group. No diffusion alterations in diffusion-weighted images were detected in the infra- and supratentorial brain areas during migraine attacks in patients with and without aura. (orig.)

  12. Cerebral and cerebellar ADC values during a migraine attack

    International Nuclear Information System (INIS)

    Degirmenci, Bumin; Haktanir, Alpay; Albayrak, Ramazan; Acar, Murat; Yaman, Mehmet

    2007-01-01

    We investigated the diffusion-weighted MRI changes, apparent diffusion coefficient (ADC) values, and conventional MRI findings in specific brain areas during migraine attacks in patients with and without aura. Included in the study were 22 patients (2 male, 20 female) aged between 17 and 49 years who were diagnosed as having migraine according to the diagnostic criteria of the International Headache Society. Also included in the study were 18 age- and sex-matched healthy volunteers. Hyperintense lesions were evaluated in conventional MR images. Heavily diffusion-weighted images, ADC maps, and segmented ADC maps generated for regional ADC (rADC) measurements, were also studied. ADC values from specific brain areas were used with appropriate region of interests (ROI). Migraine with aura was diagnosed in 13 patients and migraine without aura was diagnosed in 9 patients. A total of 23 hyperintense lesions within the periventricular white matter and deep white matter were detected in five patients (21.8%). All of these hyperintense lesions were seen in migraine patients with aura. In only one patient did a hyperintense lesion show an increased diffusion pattern on diffusion-weighted images and ADC maps. One hyperintense lesion was detected in the control group (5.5%). There was no significant difference in ADC values between the migraine and control groups. T2-weighted hyperintense lesions were significantly more frequent in migraine patients especially in those with aura than in the control group. No diffusion alterations in diffusion-weighted images were detected in the infra- and supratentorial brain areas during migraine attacks in patients with and without aura. (orig.)

  13. A low-power small-area ADC array for IRFPA readout

    Science.gov (United States)

    Zhong, Shengyou; Yao, Libin

    2013-09-01

    The readout integrated circuit (ROIC) is a bridge between the infrared focal plane array (IRFPA) and image processing circuit in an infrared imaging system. The ROIC is the first part of signal processing circuit and connected to detectors directly, so its performance will greatly affect the detector or even the whole imaging system performance. With the development of CMOS technologies, it's possible to digitalize the signal inside the ROIC and develop the digital ROIC. Digital ROIC can reduce complexity of the whole system and improve the system reliability. More importantly, it can accommodate variety of digital signal processing techniques which the traditional analog ROIC cannot achieve. The analog to digital converter (ADC) is the most important building block in the digital ROIC. The requirements for ADCs inside the ROIC are low power, high dynamic range and small area. In this paper we propose an RC hybrid Successive Approximation Register (SAR) ADC as the column ADC for digital ROIC. In our proposed ADC structure, a resistor ladder is used to generate several voltages. The proposed RC hybrid structure not only reduces the area of capacitor array but also releases requirement for capacitor array matching. Theory analysis and simulation show RC hybrid SAR ADC is suitable for ADC array applications

  14. Two-step single slope/SAR ADC with error correction for CMOS image sensor.

    Science.gov (United States)

    Tang, Fang; Bermak, Amine; Amira, Abbes; Amor Benammar, Mohieddine; He, Debiao; Zhao, Xiaojin

    2014-01-01

    Conventional two-step ADC for CMOS image sensor requires full resolution noise performance in the first stage single slope ADC, leading to high power consumption and large chip area. This paper presents an 11-bit two-step single slope/successive approximation register (SAR) ADC scheme for CMOS image sensor applications. The first stage single slope ADC generates a 3-bit data and 1 redundant bit. The redundant bit is combined with the following 8-bit SAR ADC output code using a proposed error correction algorithm. Instead of requiring full resolution noise performance, the first stage single slope circuit of the proposed ADC can tolerate up to 3.125% quantization noise. With the proposed error correction mechanism, the power consumption and chip area of the single slope ADC are significantly reduced. The prototype ADC is fabricated using 0.18 μ m CMOS technology. The chip area of the proposed ADC is 7 μ m × 500 μ m. The measurement results show that the energy efficiency figure-of-merit (FOM) of the proposed ADC core is only 125 pJ/sample under 1.4 V power supply and the chip area efficiency is 84 k  μ m(2) · cycles/sample.

  15. Two-Step Single Slope/SAR ADC with Error Correction for CMOS Image Sensor

    Directory of Open Access Journals (Sweden)

    Fang Tang

    2014-01-01

    Full Text Available Conventional two-step ADC for CMOS image sensor requires full resolution noise performance in the first stage single slope ADC, leading to high power consumption and large chip area. This paper presents an 11-bit two-step single slope/successive approximation register (SAR ADC scheme for CMOS image sensor applications. The first stage single slope ADC generates a 3-bit data and 1 redundant bit. The redundant bit is combined with the following 8-bit SAR ADC output code using a proposed error correction algorithm. Instead of requiring full resolution noise performance, the first stage single slope circuit of the proposed ADC can tolerate up to 3.125% quantization noise. With the proposed error correction mechanism, the power consumption and chip area of the single slope ADC are significantly reduced. The prototype ADC is fabricated using 0.18 μm CMOS technology. The chip area of the proposed ADC is 7 μm × 500 μm. The measurement results show that the energy efficiency figure-of-merit (FOM of the proposed ADC core is only 125 pJ/sample under 1.4 V power supply and the chip area efficiency is 84 k μm2·cycles/sample.

  16. VMEbus interface for spectroscopy ADCs

    International Nuclear Information System (INIS)

    Jaeaeskelaeinen, M.

    1987-01-01

    A high performance VMEbus interface for spectroscopy ADCs and other similar devices used in nuclear spectroscopy coincidence experiments has been developed. This new module can be used to interface existing spectroscopy ADCs with fast parallel data transfer into the industry standard multiprocessor VMEbus. The unit provides a fast direct readout of the ADC data into the VMEbus memory. The interface also has built-in capabilities that enable it to be used in coincidence experiments for slow data timing and ADC pattern recognition. (orig.)

  17. Accuracy Limitations of Pipelined ADCs

    NARCIS (Netherlands)

    Quinn, P.J.; Roermund, van A.H.M.

    2005-01-01

    In this paper, the key characteristics of the main errors which affect the performance of a switched capacitor pipelined ADC are presented and their effects on the ADC transfer characteristics demonstrated. Clear and concise relationships are developed to aid optimized design of the pipeline ADC and

  18. AdcAII of Streptococcus pneumoniae Affects Pneumococcal Invasiveness.

    Directory of Open Access Journals (Sweden)

    Lindsey R Brown

    Full Text Available Across bacterial species, metal binding proteins can serve functions in pathogenesis in addition to regulating metal homeostasis. We have compared and contrasted the activities of zinc (Zn2+-binding lipoproteins AdcA and AdcAII in the Streptococcus pneumoniae TIGR4 background. Exposure to Zn2+-limiting conditions resulted in delayed growth in a strain lacking AdcAII (ΔAdcAII when compared to wild type bacteria or a mutant lacking AdcA (ΔAdcA. AdcAII failed to interact with the extracellular matrix protein laminin despite homology to laminin-binding proteins of related streptococci. Deletion of AdcA or AdcAII led to significantly increased invasion of A549 human lung epithelial cells and a trend toward increased invasion in vivo. Loss of AdcAII, but not AdcA, was shown to negatively impact early colonization of the nasopharynx. Our findings suggest that expression of AdcAII affects invasiveness of S. pneumoniae in response to available Zn2+ concentrations.

  19. Development of an ADC Radiation Tolerance Characterization System for the Upgrade of the ATLAS LAr Calorimeter

    CERN Document Server

    INSPIRE-00445642; Chen, Kai; Kierstead, James; Lanni, Francesco; Takai, Helio; Jin, Ge

    2016-01-01

    ATLAS LAr calorimeter will perform its Phase-I upgrade during the long shut down (LS2) in 2018, a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multichannel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for LTDB. In order to evaluate the radiation tolerance of these back up commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, which has ADC driver and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as DAQ board. The data from ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed wit...

  20. An 'ADC-Memory' system based on a new principle in data access

    International Nuclear Information System (INIS)

    Pan Dajing; Wu Yongqing; Wang Shibo

    1990-01-01

    A new kind of 'ADC-Memory' (ADC-M) with real time correction of counting loss in dead time is now used in a multiuser data acquisition and processing system based on DUAL/68000 microcomputer. In data access, it replaces the 'DMA + 1' in classical MCA with the new method 'DMA + N', where N is weight factor of correction. The new method is based on the principle of virtual pulse generator. This method is superior to the correction by the software because the correction needn't take the computer time. Thus, this ADC-M can be used in the counting of high rate pulses

  1. ADC multi-site test based on a pre-test with digital input stimulus

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Metra, C.; Kerkhoff, Hans G.; Zjajo, Amir; Gronthoud, Guido

    2012-01-01

    This paper describes two novel algorithms based on the time-modulo reconstruction method intended for detection of the parametric faults in analogue-to-digital converters (ADC). In both algorithms, a pulse signal, in its slightly adapted form to allow sufficient time for converter settling, is taken

  2. Algorithms for ADC multi-site test with digital input stimulus

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.; Zjajo, Amir; Gronthoud, Guido

    2009-01-01

    This paper reports two novel algorithms based on time-modulo reconstruction method intended for detection of the parametric faults in analogue-to-digital converters (ADC). In both algorithms, a pulse signal, in its slightly adapted form to allow sufficient time for converter settling, is taken as

  3. Performance of flash ADCs in the 100 MHz range: I. Test bench and preliminary results

    International Nuclear Information System (INIS)

    Crawley, H.B.; McKay, R.; Meyer, W.T.; Rosenberg, E.I.; Thomas, W.D.

    1990-01-01

    We describe a systematic study of the performance of commercially available Flash ADCs in the 100 Megasample per second range, which might be suitable for use in the Superconducting Super Collider. Performance characteristics are measured using a CAMAC based test bench which is described. Among the FADC performance characteristics reported are linearity, differential linearity and the effective number of bits. This paper is the first in a series of reports to be presented within the next year as our tests continue. 6 refs., 2 figs., 1 tab

  4. Pseudo Asynchronous Level Crossing adc for ecg Signal Acquisition.

    Science.gov (United States)

    Marisa, T; Niederhauser, T; Haeberlin, A; Wildhaber, R A; Vogel, R; Goette, J; Jacomet, M

    2017-02-07

    A new pseudo asynchronous level crossing analogue-to-digital converter (adc) architecture targeted for low-power, implantable, long-term biomedical sensing applications is presented. In contrast to most of the existing asynchronous level crossing adc designs, the proposed design has no digital-to-analogue converter (dac) and no continuous time comparators. Instead, the proposed architecture uses an analogue memory cell and dynamic comparators. The architecture retains the signal activity dependent sampling operation by generating events only when the input signal is changing. The architecture offers the advantages of smaller chip area, energy saving and fewer analogue system components. Beside lower energy consumption the use of dynamic comparators results in a more robust performance in noise conditions. Moreover, dynamic comparators make interfacing the asynchronous level crossing system to synchronous processing blocks simpler. The proposed adc was implemented in [Formula: see text] complementary metal-oxide-semiconductor (cmos) technology, the hardware occupies a chip area of 0.0372 mm 2 and operates from a supply voltage of [Formula: see text] to [Formula: see text]. The adc's power consumption is as low as 0.6 μW with signal bandwidth from [Formula: see text] to [Formula: see text] and achieves an equivalent number of bits (enob) of up to 8 bits.

  5. A study of ADC value in PROPELLER DWI

    International Nuclear Information System (INIS)

    Naka, Takanori; Takahashi, Mitsuyuki

    2009-01-01

    Diffusion weighted imaging (DWI) is rapidly becoming widespread in MRI, with many reports of the differential diagnosis using the Apparent Diffusion Coefficient (ADC) being seen. We examined the influence of scan parameter on ADC in periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)-DWI. Neither the repetition time (TR) nor T1 value had a major influence on the ADC value. Number of motion probing gradient (MPG) pulse, effective echo time (TE), and T2 value were the factors in which the ADC value was changed. In addition, the ADC value has been changed by the scan sequence. The factor that influenced the ADC value was able to be confirmed by this experiment. It is necessary to understand the influence that an individual factor has on ADC. (author)

  6. A 9-Bit 50 MSPS Quadrature Parallel Pipeline ADC for Communication Receiver Application

    Science.gov (United States)

    Roy, Sounak; Banerjee, Swapna

    2018-03-01

    This paper presents the design and implementation of a pipeline Analog-to-Digital Converter (ADC) for superheterodyne receiver application. Several enhancement techniques have been applied in implementing the ADC, in order to relax the target specifications of its building blocks. The concepts of time interleaving and double sampling have been used simultaneously to enhance the sampling speed and to reduce the number of amplifiers used in the ADC. Removal of a front end sample-and-hold amplifier is possible by employing dynamic comparators with switched capacitor based comparison of input signal and reference voltage. Each module of the ADC comprises two 2.5-bit stages followed by two 1.5-bit stages and a 3-bit flash stage. Four such pipeline ADC modules are time interleaved using two pairs of non-overlapping clock signals. These two pairs of clock signals are in phase quadrature with each other. Hence the term quadrature parallel pipeline ADC has been used. These configurations ensure that the entire ADC contains only eight operational-trans-conductance amplifiers. The ADC is implemented in a 0.18-μm CMOS process and supply voltage of 1.8 V. The proto-type is tested at sampling frequencies of 50 and 75 MSPS producing an Effective Number of Bits (ENOB) of 6.86- and 6.11-bits respectively. At peak sampling speed, the core ADC consumes only 65 mW of power.

  7. A 16 bit camac ADC with memory

    International Nuclear Information System (INIS)

    Wikne, J.C.

    1986-01-01

    A 16 bit camac-programmable analog-to-digital converter (ADC) with incorporated memory and sampling clock is described. This single-width camac module is especially suited for autonomous, multi-sample data acquisition with high precision. The ADC itself is a hybrid, the ADC76 from Burr-Brown, featuring a programmable input range and direct parallel output in two's complement form. The input programming is done by means of dual-in-line switches, giving input spans from 1.25 V to 20 V, unipolar or bipolar. The outline of the programming of the ADC input and the calibration of the unit is given

  8. Utility of DWI with quantitative ADC values in ovarian tumors: a meta-analysis of diagnostic test performance.

    Science.gov (United States)

    Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui

    2018-01-01

    Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.

  9. Interpolation algorithm for asynchronous ADC-data

    Directory of Open Access Journals (Sweden)

    S. Bramburger

    2017-09-01

    Full Text Available This paper presents a modified interpolation algorithm for signals with variable data rate from asynchronous ADCs. The Adaptive weights Conjugate gradient Toeplitz matrix (ACT algorithm is extended to operate with a continuous data stream. An additional preprocessing of data with constant and linear sections and a weighted overlap of step-by-step into spectral domain transformed signals improve the reconstruction of the asycnhronous ADC signal. The interpolation method can be used if asynchronous ADC data is fed into synchronous digital signal processing.

  10. Performance evaluation of the analogue front-end and ADC prototypes for the Gotthard-II development

    Science.gov (United States)

    Zhang, J.; Andrä, M.; Barten, R.; Bergamaschi, A.; Brückner, M.; Dinapoli, R.; Fröjdh, E.; Greiffenberg, D.; Lopez-Cuenca, C.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Redford, S.; Ruat, M.; Ruder, C.; Schmitt, B.; Shi, X.; Thattil, D.; Tinti, G.; Turcato, M.; Vetter, S.

    2017-12-01

    Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a silicon microstrip sensor with a pitch of 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to readout chips (ROCs). In the ROC, an adaptive gain switching pre-amplifier (PRE), a fully differential Correlated-Double-Sampling (CDS) stage, an Analog-to-Digital Converter (ADC) as well as a Static Random-Access Memory (SRAM) capable of storing all the 2700 images in an XFEL.EU bunch train will be implemented. Several prototypes with different designs of the analogue front-end (PRE and CDS) and ADC test structures have been fabricated in UMC-110 nm CMOS technology and their performance has been evaluated. In this paper, the performance of the analogue front-end and ADC will be summarized.

  11. Normalization of ADC does not improve correlation with overall survival in patients with high-grade glioma (HGG).

    Science.gov (United States)

    Qin, Lei; Li, Angie; Qu, Jinrong; Reinshagen, Katherine; Li, Xiang; Cheng, Su-Chun; Bryant, Annie; Young, Geoffrey S

    2018-04-01

    Mixed reports leave uncertainty about whether normalization of apparent diffusion coefficient (ADC) to a within-subject white matter reference is necessary for assessment of tumor cellularity. We tested whether normalization improves the previously reported correlation of resection margin ADC with 15-month overall survival (OS) in HGG patients. Spin-echo echo-planar DWI was retrieved from 3 T MRI acquired between maximal resection and radiation in 37 adults with new-onset HGG (25 glioblastoma; 12 anaplastic astrocytoma). ADC maps were produced with the FSL DTIFIT tool (Oxford Centre for Functional MRI). 3 neuroradiologists manually selected regions of interest (ROI) in normal appearing white matter (NAWM) and in non-enhancing tumor (NT) Normalized ADC (nADC) was computed as the ratio of absolute NT ADC to NAWM ADC. Reproducibility of nADC and absolute ADC among the readers' ROI was assessed using intra-class correlation coefficient (ICC) and within-subject coefficient of variation (wCV). Correlations of ADC and nADC with OS were compared using receiver operating characteristics (ROC) analysis. A p value 0.05 was considered statistically significant. Both mean ADC and nADC differed significantly between patients subgrouped by 15-month OS (p = 0.0014 and 0.0073 respectively). wCV and ICC among the readers were similar for absolute and normalized ADC. In ROC analysis of correlation with OS, nADC did not perform significantly better than absolute ADC. Normalization does not significantly improve the correlation of absolute ADC with OS in HGG, suggesting that normalization is not necessary for clinical or research ADC analysis in HGG patients.

  12. ADC mapping of benign and malignant breast tumors

    International Nuclear Information System (INIS)

    Woodhams, R.; Matsunaga, Keiji; Kan, Shinichi; Hata, Hirofumi; Iwabuchi, Keiichi; Kuranami, Masaru; Watanabe, Masahiko; Hayakawa, Kazushige; Ozaki, Masanori

    2005-01-01

    The purpose of this study was to investigate the utility of diffusion-weighted imaging (DWI) and the apparent diffusion coefficient (ADC) value in differentiating benign and malignant breast lesions and evaluating the detection accuracy of the cancer extension. We used DWI to obtain images of 191 benign and malignant lesions (24 benign, 167 malignant) before surgical excision. The ADC values of the benign and malignant lesions were compared, as were the values of noninvasive ductal carcinoma (NIDC) and invasive ductal carcinoma (IDC). We also evaluated the ADC map, which represents the distribution of ADC values, and compared it with the cancer extension. The mean ADC value of each type of lesion was as follows: malignant lesions, 1.22±0.31 x 10 -3 mm 2 /s; benign lesions, 1.67±0.54 x 10 -3 mm 2 /s; normal tissues, 2.09±0.27 x 10 -3 mm 2 /s. The mean ADC value of the malignant lesions was statistically lower than that of the benign lesions and normal breast tissues. The ADC value of IDC was statistically lower than that of NIDC. The sensitivity of the ADC value for malignant lesions with a threshold of less than 1.6 x 10 -3 mm 2 /s was 95% and the specificity was 46%. A full 75% of all malignant cases exhibited a near precise distribution of low ADC values on ADC maps to describe malignant lesions. The main causes of false negative and underestimation of cancer spread were susceptibility artifact because of bleeding and tumor structure. Major histologic types of false-positive lesions were intraductal papilloma and fibrocystic diseases. Fibrocystic diseases also resulted in overestimation of cancer extension. DWI has the potential in clinical appreciation to detect malignant breast tumors and support the evaluation of tumor extension. However, the benign proliferative change remains to be studied as it mimics the malignant phenomenon on the ADC map. (author)

  13. Exploring dynamics of embedded ADC through adapted digital input stimuli

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.; Zjajo, A.; Gronthoud, G.

    2008-01-01

    This paper reports an evaluation of adapted digital signals as a test stimulus to test dynamic parameters of analog-to-digital converters (ADC). In the first instance, the simplest digital waveform, a pulse signal, is taken as the test stimulus. The dynamics of the device under test while applying

  14. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    Energy Technology Data Exchange (ETDEWEB)

    Palmucci, S., E-mail: spalmucci@sirm.org; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-15

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm{sup 2}/sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm{sup 2}/s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm{sup 2}/s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm{sup 2}/s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to

  15. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    International Nuclear Information System (INIS)

    Palmucci, S.; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-01

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm 2 /sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm 2 /s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm 2 /s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm 2 /s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to investigate better

  16. Endometrial cancer: correlation of apparent diffusion coefficient (ADC) with tumor cellularity and tumor grade.

    Science.gov (United States)

    Kishimoto, Keiko; Tajima, Shinya; Maeda, Ichiro; Takagi, Masayuki; Ueno, Takahiko; Suzuki, Nao; Nakajima, Yasuo

    2016-08-01

    Diffusion-weighted imaging (DWI) and the apparent diffusion coefficient (ADC) are widely used for detecting uterine endometrial cancer. The relationships between ADC values and pathological features of endometrial cancer have not yet been established. To investigate whether ADC values of endometrial cancer vary according to histologic tumor cellularity and tumor grade. We retrospectively reviewed 30 pathologically confirmed endometrial cancers. All patients underwent conventional non-enhanced magnetic resonance imaging (MRI) and DWI procedures, and ADC values were calculated. Tumor cellularity was evaluated by counting cancer cells in three high-power ( × 400) fields. The correlation between ADC values and tumor cellularity was assessed using Pearson's correlation coefficient test for statistical analysis. The mean ± standard deviation (SD) ADC value ( ×10(-3) mm(2)/s) of endometrial cancer was 0.85 ± 0.22 (range, 0.55-1.71). The mean ± SD tumor cellularity was 528.36 ± 16.89 (range, 298.0-763.6). ADC values were significantly inversely correlated with tumor cellularity. No significant relationship was observed between ADC values and tumor grade (mean ADC values: G1, 0.88 ± 0.265 × 10(-3) mm(2)/s; G2, 0.80 ± 0.178 × 10(-3) mm(2)/s; G3, 0.81 ± 0.117 × 10(-3) mm(2)/s). There is a significant inverse relationship between ADC values and tumor cellularity in endometrial cancer. No significant differences in average ADC value were observed between G1, G2, and G3 tumors. However, the lower the tumor grade, the wider the SD. © The Foundation Acta Radiologica 2015.

  17. Different methods of measuring ADC values in normal human brain

    International Nuclear Information System (INIS)

    Wei Youping; Sheng Junkang; Zhang Caiyuan

    2009-01-01

    Objective: To investigate better method of measuring ADC values of normal brain, and provide reference for further research. Methods: Twenty healthy people's MR imaging were reviewed. All of them underwent routine MRI scans and echo-planar diffusion-weighted imaging (DWI), and ADC maps were reconstructed on work station. Six regions of interest (ROI) were selected for each object, the mean ADC values were obtained for each position on DWI and ADC maps respectively. Results: On the anisotropic DWI map calculated in the hypothalamus, ADC M , ADC P , ADC S values were no significant difference (P>0.05), in the frontal white matter and internal capsule hindlimb, there was a significant difference (P ave value exist significant difference to direct measurement on the anisotropic (isotropic) ADC map (P<0.001). Conclusion: Diffusion of water in the frontal white matter and internal capsule are anisotropic, but it is isotropic in the hypothalamus; different quantitative methods of diffusion measurement of 4ADC values have significant difference, but ADC values calculated through the DWI map is more accurate, quantitative diffusion study of brain tissue should also consider the diffusion measurement method. (authors)

  18. Design and Implementation of Decimation Filter for 13-bit Sigma-Delta ADC Based on FPGA

    Directory of Open Access Journals (Sweden)

    Khalid Khaleel Mohammed

    2016-10-01

    Full Text Available A 13 bit Sigma-Delta ADC for a signal band of 40K Hz is designed in MATLAB Simulink and then implemented using Xilinx system generator tool.  The first order Sigma-Delta modulator is designed to work at a signal band of 40 KHz at an oversampling ratio (OSR of 256 with a sampling frequency of 20.48 MHz. The proposed decimation filter design is consists of a second order Cascaded Integrator Comb filter (CIC followed by two finite impulse response (FIR filters. This architecture reduces the need for multiplication which is need very large area. This architecture implements a decimation ratio of 256 and allows a maximum resolution of 13  bits in the output of the filter. The decimation filter was designed  and  tested  in  Xilinx  system  generator  tool  which  reduces  the  design  cycle  by  directly generating efficient VHDL code. The results obtained show that the overall Sigma-Delta ADC is able to achieve an ENOB (Effective Number Of Bit of 13.71 bits and SNR of 84.3 dB

  19. Basic Block of Pipelined ADC Design Requirements

    Directory of Open Access Journals (Sweden)

    V. Kledrowetz

    2011-04-01

    Full Text Available The paper describes design requirements of a basic stage (called MDAC - Multiplying Digital-to- Analog Converter of a pipelined ADC. There exist error sources such as finite DC gain of opamp, capacitor mismatch, thermal noise, etc., arising when the switched capacitor (SC technique and CMOS technology are used. These non-idealities are explained and their influences on overall parameters of a pipelined ADC are studied. The pipelined ADC including non-idealities was modeled in MATLAB - Simulink simulation environment.

  20. The Adc/Lmb System Mediates Zinc Acquisition in Streptococcus agalactiae and Contributes to Bacterial Growth and Survival.

    Science.gov (United States)

    Moulin, Pauline; Patron, Kévin; Cano, Camille; Zorgani, Mohamed Amine; Camiade, Emilie; Borezée-Durant, Elise; Rosenau, Agnès; Mereghetti, Laurent; Hiron, Aurélia

    2016-12-15

    The Lmb protein of Streptococcus agalactiae is described as an adhesin that binds laminin, a component of the human extracellular matrix. In this study, we revealed a new role for this protein in zinc uptake. We also identified two Lmb homologs, AdcA and AdcAII, redundant binding proteins that combine with the AdcCB translocon to form a zinc-ABC transporter. Expression of this transporter is controlled by the zinc concentration in the medium through the zinc-dependent regulator AdcR. Triple deletion of lmb, adcA, and adcAII, or that of the adcCB genes, impaired growth and cell separation in a zinc-restricted environment. Moreover, we found that this Adc zinc-ABC transporter promotes S. agalactiae growth and survival in some human biological fluids, suggesting that it contributes to the infection process. These results indicated that zinc has biologically vital functions in S. agalactiae and that, under the conditions tested, the Adc/Lmb transporter constitutes the main zinc acquisition system of the bacterium. A zinc transporter, composed of three redundant binding proteins (Lmb, AdcA, and AdcAII), was characterized in Streptococcus agalactiae This system was shown to be essential for bacterial growth and morphology in zinc-restricted environments, including human biological fluids. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  1. A 72-dB-SNDR rail-to-rail successive approximation ADC using mismatch calibration techniques

    International Nuclear Information System (INIS)

    Liu Yan; Hua Siliang; Wang Donghui; Hou Chaohuan

    2012-01-01

    When the voltage of an analog input signal is equal to the supply voltage, it is difficult for a conventional successive approximation ADC to correctly convert the analog signal into digital signal. This paper introduces an improved successive approximation ADC, which can convert the rail-to-rail input range and reduce sampling time through a track-and-hold circuit. Comparator offset cancellation and capacitor self-calibration techniques are used in this ADC. Measurement results show that the peak SNDR of this ADC reaches 72 dB and the signal effective bandwidth is up to 1.25 MHz. It consumes 1 mW in the test, and the figure of merit is 123 fJ/conversion-step. (semiconductor integrated circuits)

  2. High performance 14-bit pipelined redundant signed digit ADC

    International Nuclear Information System (INIS)

    Narula, Swina; Pandey, Sujata

    2016-01-01

    A novel architecture of a pipelined redundant-signed-digit analog to digital converter (RSD-ADC) is presented featuring a high signal to noise ratio (SNR), spurious free dynamic range (SFDR) and signal to noise plus distortion (SNDR) with efficient background correction logic. The proposed ADC architecture shows high accuracy with a high speed circuit and efficient utilization of the hardware. This paper demonstrates the functionality of the digital correction logic of 14-bit pipelined ADC at each 1.5 bit/stage. This prototype of ADC architecture accounts for capacitor mismatch, comparator offset and finite Op-Amp gain error in the MDAC (residue amplification circuit) stages. With the proposed architecture of ADC, SNDR obtained is 85.89 dB, SNR is 85.9 dB and SFDR obtained is 102.8 dB at the sample rate of 100 MHz. This novel architecture of digital correction logic is transparent to the overall system, which is demonstrated by using 14-bit pipelined ADC. After a latency of 14 clocks, digital output will be available at every clock pulse. To describe the circuit behavior of the ADC, VHDL and MATLAB programs are used. The proposed architecture is also capable of reducing the digital hardware. Silicon area is also the complexity of the design. (paper)

  3. Column-Parallel Single Slope ADC with Digital Correlated Multiple Sampling for Low Noise CMOS Image Sensors

    NARCIS (Netherlands)

    Chen, Y.; Theuwissen, A.J.P.; Chae, Y.

    2011-01-01

    This paper presents a low noise CMOS image sensor (CIS) using 10/12 bit configurable column-parallel single slope ADCs (SS-ADCs) and digital correlated multiple sampling (CMS). The sensor used is a conventional 4T active pixel with a pinned-photodiode as photon detector. The test sensor was

  4. Implementation of integrated circuit and design of SAR ADC for fully implantable hearing aids.

    Science.gov (United States)

    Kim, Jong Hoon; Lee, Jyung Hyun; Cho, Jin-Ho

    2017-07-20

    The hearing impaired population has been increasing; many people suffer from hearing problems. To deal with this difficulty, various types of hearing aids are being rapidly developed. In particular, fully implantable hearing aids are being actively studied to improve the performance of existing hearing aids and to reduce the stigma of hearing loss patients. It has to be of small size and low-power consumption for easy implantation and long-term use. The objective of the study was to implement a small size and low-power consumption successive approximation register analog-to-digital converter (SAR ADC) for fully implantable hearing aids. The ADC was selected as the SAR ADC because its analog circuit components are less required by the feedback circuit of the SAR ADC than the sigma-delta ADC which is conventionally used in hearing aids, and it has advantages in the area and power consumption. So, the circuit of SAR ADC is designed considering the speech region of humans because the objective is to deliver the speech signals of humans to hearing loss patients. If the switch of sample and hold works in the on/off positions, the charge injection and clock feedthrough are produced by a parasitic capacitor. These problems affect the linearity of the hold voltage, and as a result, an error of the bit conversion is generated. In order to solve the problem, a CMOS switch that consists of NMOS and PMOS was used, and it reduces the charge injection because the charge carriers in the NMOS and PMOS have inversed polarity. So, 16 bit conversion is performed before the occurrence of the Least Significant Bit (LSB) error. In order to minimize the offset voltage and power consumption of the designed comparator, we designed a preamplifier with current mirror. Therefore, the power consumption was reduced by the power control switch used in the comparator. The layout of the designed SAR ADC was performed by Virtuoso Layout Editor (Cadence, USA). In the layout result, the size of the

  5. NRL 12-Bit, 213 Msps ADC HSAD9 MCM Evaluation Board

    National Research Council Canada - National Science Library

    Thai, Khanh

    1999-01-01

    The MCM Evaluation Board is a 6" by 6" test fixture designed for evaluating the HSAD9 MCM, a completely self contained ADC multichip module that digitizes incoming differential analog signals to 12...

  6. A low power 12-bit ADC for nuclear instrumentation

    International Nuclear Information System (INIS)

    Adachi, R.; Landis, D.; Madden, N.; Silver, E.; LeGros, M.

    1992-10-01

    A low power, successive approximation, analog-to-digital converter (ADC) for low rate, low cost, battery powered applications is described. The ADC is based on a commercial 50 mW successive approximation CMOS device (CS5102). An on-chip self-calibration circuit reduces the inherent differential nonlinearity to 7%. A further reduction of the differential nonlinearity to 0.5% is attained with a four bit Gatti function. The Gatti function is distributed to minimize battery power consumption. All analog functions reside with the ADC while the noisy digital functions reside in the personal computer based histogramming memory. Fiber optic cables carry afl digital information between the ADC and the personal computer based histogramming memory

  7. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Ingebretsen, F.; Holt, K.; Skaali, B.

    1983-04-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configuration of singles and multiparameter events from 1 up to 15 ADC's in one crate

  8. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Holt, K.; Ingebretsen, F.; Skaali, B.

    1983-01-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configurations of singles and multiparameter events from 1 up to 15 ADC's in one crate

  9. Role of Arginine decarboxylase (ADC) in Arabidopsis thaliana defence against the pathogenic bacterium Pseudomonas viridiflava.

    Science.gov (United States)

    Rossi, F R; Marina, M; Pieckenstain, F L

    2015-07-01

    Polyamine biosynthesis starts with putrescine production through the decarboxylation of arginine or ornithine. In Arabidopsis thaliana, putrescine is synthesised exclusively by arginine decarboxylase (ADC), which exists as two isoforms (ADC1 and 2) that are differentially regulated by abiotic stimuli, but their role in defence against pathogens has not been studied in depth. This work analysed the participation of ADC in Arabidopsis defence against Pseudomonas viridiflava. ADC activity and expression, polyamine levels and bacterial resistance were analysed in null mutants of each ADC isoform. In non-infected wild-type (WT) plants, ADC2 expression was much higher than ADC1. Analysis of adc mutants demonstrated that ADC2 contributes to a much higher extent than ADC1 to basal ADC activity and putrescine biosynthesis. In addition, adc2 mutants showed increased basal expression of salicylic acid- and jasmonic acid-dependent PR genes. Bacterial infection induced putrescine accumulation and ADC1 expression in WT plants, but pathogen-induced putrescine accumulation was blocked in adc1 mutants. Results suggest a specific participation of ADC1 in defence, although basal resistance was not decreased by dysfunction of either of the two ADC genes. In addition, and as opposed to WT plants, bacterial infection increased ADC2 expression and ADC activity in adc1 mutants, which could counterbalance the lack of ADC1. Results demonstrate a major contribution of ADC2 to total ADC activity and the specific induction of ADC1 in response to infection. A certain degree of functional redundancy between the two isoforms in relation to their contribution to basal resistance is also evident. © 2015 German Botanical Society and The Royal Botanical Society of the Netherlands.

  10. Real time prediction and correction of ADCS problems in LEO satellites using fuzzy logic

    Directory of Open Access Journals (Sweden)

    Yassin Mounir Yassin

    2017-06-01

    Full Text Available This approach is concerned with adapting the operations of attitude determination and control subsystem (ADCS of low earth orbit LEO satellites through analyzing the telemetry readings received by mission control center, and then responding to ADCS off-nominal situations. This can be achieved by sending corrective operational Tele-commands within real time. Our approach is related to the fuzzy membership of off-nominal telemetry readings of corrective actions through a set of fuzzy rules based on understanding the ADCS modes resulted from the satellite telemetry readings. Response in real time gives us a chance to avoid risky situations. The approach is tested on the EgyptSat-1 engineering model, which is our method to simulate the results.

  11. Increased tumour ADC value during chemotherapy predicts improved survival in unresectable pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nishiofuku, Hideyuki; Tanaka, Toshihiro; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology and IVR Center, Kashihara-city, Nara (Japan); Marugami, Nagaaki [Nara Medical University, Department of Endoscopy and Ultrasound, Kashihara-city, Nara (Japan); Sho, Masayuki; Akahori, Takahiro; Nakajima, Yoshiyuki [Nara Medical University, Department of Surgery, Kashihara-city, Nara (Japan)

    2016-06-15

    To investigate whether changes to the apparent diffusion coefficient (ADC) of primary tumour in the early period after starting chemotherapy can predict progression-free survival (PFS) or overall survival (OS) in patients with unresectable pancreatic adenocarcinoma. Subjects comprised 43 patients with histologically confirmed unresectable pancreatic cancer treated with first-line chemotherapy. Minimum ADC values in primary tumour were measured using the selected area ADC (sADC), which excluded cystic and necrotic areas and vessels, and the whole tumour ADC (wADC), which included whole tumour components. Relative changes in ADC were calculated from baseline to 4 weeks after initiation of chemotherapy. Relationships between ADC and both PFS and OS were modelled by Cox proportional hazards regression. Median PFS and OS were 6.1 and 11.0 months, respectively. In multivariate analysis, sADC change was the strongest predictor of PFS (hazard ratio (HR), 4.5; 95 % confidence interval (CI), 1.7-11.9; p = 0.002). Multivariate Cox regression analysis for OS revealed sADC change and CRP as independent predictive markers, with sADC change as the strongest predictive biomarker (HR, 6.7; 95 % CI, 2.7-16.6; p = 0.001). Relative changes in sADC could provide a useful imaging biomarker to predict PFS and OS with chemotherapy for unresectable pancreatic adenocarcinoma. (orig.)

  12. Evaluation of Multi-Channel ADCs for Gamma-Ray Spectroscopy

    Science.gov (United States)

    Tan, Hui; Hennig, Wolfgang; Walby, Mark D.; Breus, Dimitry; Harris, Jackson

    2013-04-01

    As nuclear physicists increasingly design large scale experiments with hundreds or thousands of detector channels, there are growing needs for high density readout electronics with good timing and energy resolution that at the same time offer lower cost per channel compared to existing commercial solutions. Recent improvements in the design of commercial analog to digital converters (ADCs) have resulted in a variety of multi-channel ADCs that are natural choice for designing such high density readout modules. However, multi-channel ADCs typically are designed for medical imaging/ultrasound applications and therefore are not rated for their spectroscopic characteristics. In this work, we evaluated the gamma-ray spectroscopic performance of several multi-channel ADCs, including their energy resolution, nonlinearity, and timing resolution. Some of these ADCs demonstrated excellent energy resolution, 2.66% FWHM at 662 keV with a LaBr3 or 1.78 keV FWHM at 1332.5 keV with a high purity germanium (HPGe) detector, and sub-nanosecond timing resolution with LaBr 3. We present results from these measurements to illustrate their suitability for gamma-ray spectroscopy.

  13. ADC Histogram Analysis of Cervical Cancer Aids Detecting Lymphatic Metastases-a Preliminary Study.

    Science.gov (United States)

    Schob, Stefan; Meyer, Hans Jonas; Pazaitis, Nikolaos; Schramm, Dominik; Bremicker, Kristina; Exner, Marc; Höhn, Anne Kathrin; Garnov, Nikita; Surov, Alexey

    2017-12-01

    Apparent diffusion coefficient (ADC) histogram analysis has been used to some extent in cervical cancer (CC) to distinguish between low-grade and high-grade tumors. Although this differentiation is undoubtedly helpful, it would be even more crucial in the presurgical setting to determine whether a tumor already gained the potential to metastasize via the lymphatic system. So far, no studies investigated the potential of 3T ADC histogram analysis in CC to differentiate between nodal-positive and nodal-negative entities. Therefore, the principal aim of our study was to investigate the potential of 3T ADC histogram analysis to differentiate between CC with and without lymph node metastasis. The second aim was to elucidate possible differences in ADC histogram parameters between CC with limited vs. advanced tumor stages and well-differentiated vs. undifferentiated lesions. Finally, correlations of p53 expression and Ki-67 index with ADC parameters were analyzed. Eighteen female patients (mean age 55.4 years, range 32-79 years) with histopathologically confirmed cervical squamous cell carcinoma of the uterine cervix were prospectively enrolled. Tumor stages, tumor grading, status of metastatic dissemination, Ki67-index, and p53 expression were assessed in these patients. Diffusion weighted imaging (DWI) was obtained in a 3T scanner using the following b values: b0 and b1000 s/mm 2 . Group comparisons using Mann-Whitney U test revealed the following findings: nodal-positive CC had statistically significant lower ADC parameters (ADCmin, ADCmean, median ADC, Mode, p10, p25, p75, and p90) in comparison to nodal-negative CC (all p histogram analysis in 3T DWI. This information is crucial for the gynecological surgeon to identify the optimal treatment strategy for patients suffering from CC. Furthermore, ADCentropy was identified as a potential imaging biomarker for tumor heterogeneity and might be able to indicate further molecular changes like loss of p53 expression

  14. Simultaneous Measurement of T2 and Apparent Diffusion Coefficient (T2+ADC) in the Heart With Motion-Compensated Spin Echo Diffusion-Weighted Imaging

    Science.gov (United States)

    Aliotta, Eric; Moulin, Kévin; Zhang, Zhaohuan; Ennis, Daniel B.

    2018-01-01

    Purpose To evaluate a technique for simultaneous quantitative T2 and apparent diffusion coefficient (ADC) mapping in the heart (T2+ADC) using spin echo (SE) diffusion-weighted imaging (DWI). Theory and Methods T2 maps from T2+ADC were compared with single-echo SE in phantoms and with T2-prepared (T2-prep) balanced steady-state free precession (bSSFP) in healthy volunteers. ADC maps from T2+ADC were compared with conventional DWI in phantoms and in vivo. T2+ADC was also demonstrated in a patient with acute myocardial infarction (MI). Results Phantom T2 values from T2+ADC were closer to a single-echo SE reference than T2-prep bSSFP (−2.3 ± 6.0% vs 22.2 ± 16.3%; P T2 values from T2+ADC were significantly shorter than T2-prep bSSFP (35.8 ± 3.1 vs 46.8 ± 3.8 ms; P T2+ADC and conventional motion-compensated DWI (1.39 ± 0.18 vs 1.38 ± 0.18 mm2/ms; P = N.S.). In the patient, T2 and ADC were both significantly elevated in the infarct compared with remote myocardium (T2: 40.4 ± 7.6 vs 56.8 ± 22.0; P T2+ADC generated coregistered, free-breathing T2 and ADC maps in healthy volunteers and a patient with acute MI with no cost in accuracy, precision, or scan time compared with DWI. PMID:28516485

  15. Locally advanced rectal cancer: post-chemoradiotherapy ADC histogram analysis for predicting a complete response.

    Science.gov (United States)

    Cho, Seung Hyun; Kim, Gab Chul; Jang, Yun-Jin; Ryeom, Hunkyu; Kim, Hye Jung; Shin, Kyung-Min; Park, Jun Seok; Choi, Gyu-Seog; Kim, See Hyung

    2015-09-01

    The value of diffusion-weighted imaging (DWI) for reliable differentiation between pathologic complete response (pCR) and residual tumor is still unclear. Recently, a few studies reported that histogram analysis can be helpful to monitor the therapeutic response in various cancer research. To investigate whether post-chemoradiotherapy (CRT) apparent diffusion coefficient (ADC) histogram analysis can be helpful to predict a pCR in locally advanced rectal cancer (LARC). Fifty patients who underwent preoperative CRT followed by surgery were enrolled in this retrospective study, non-pCR (n = 41) and pCR (n = 9), respectively. ADC histogram analysis encompassing the whole tumor was performed on two post-CRT ADC600 and ADC1000 (b factors 0, 600 vs. 0, 1000 s/mm(2)) maps. Mean, minimum, maximum, SD, mode, 10th, 25th, 50th, 75th, 90th percentile ADCs, skewness, and kurtosis were derived. Diagnostic performance for predicting pCR was evaluated and compared. On both maps, 10th and 25th ADCs showed better diagnostic performance than that using mean ADC. Tenth percentile ADCs revealed the best diagnostic performance on both ADC600 (AZ 0.841, sensitivity 100%, specificity 70.7%) and ADC1000 (AZ 0.821, sensitivity 77.8%, specificity 87.8%) maps. In comparison between 10th percentile and mean ADC, the specificity was significantly improved on both ADC600 (70.7% vs. 53.7%; P = 0.031) and ADC1000 (87.8% vs. 73.2%; P = 0.039) maps. Post-CRT ADC histogram analysis is helpful for predicting pCR in LARC, especially, in improving the specificity, compared with mean ADC. © The Foundation Acta Radiologica 2014.

  16. Performance of CAMAC TDC and ADC in magnetic field

    International Nuclear Information System (INIS)

    Gupta, S.K.; Barbier, L.M.; Christian, E.R.; Geier, S.; Krizmanic, J.F.; Mitchell, J.W.; Streitmatter, R.E.; Wasilewski, P.J.

    1997-01-01

    The performance of a LeCroy CAMAC 2228A TDC and a 2249A ADC have been studied in presence of magnetic fields up to 5000 G. The conversion gains of the TDC and ADC increased with magnetic field in a non-linear fashion which can be adequately parameterized by a fourth-order polynomial. The behavior of both the TDC and ADC can be completely understood in terms of a change in the inductance of a ferromagnetic core inductor in the 20 MHz clock circuit of these units. (orig.)

  17. Comparison of performance of analog-to-digital converters (ADC) for pulse height analyzers

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Hirai, Shoji

    1981-01-01

    In the recent ADCs for pulse height analyzers (PHA), Wilkinson type is a leading one, and those with 50 to 200 MHz clock frequency and 8K channel are mostly on the market. The comparison of the performance of ADCs was conducted under the condition of using these multi-channel PHAs as γ-ray spectrometers. The following three ADCs were compared: ADC incorporated in CANBERRA 8100 MCA, and CANBERRA 8060 ADCs used as the ADCs for 1st and 2nd GAMA systems. In this case, the conversion gains of these ADCs were set at 4K because the memory of 8100 MCA was 4K, and the GAMA systems were also mostly operated at 4K. In this paper, report is made on the measurements of dead time, the change of γ peaks immediately after the power was turned on, the temperature dependence of ADCs the long term stability of ADCs, derivative non-linearity, and integration non-linearity. The dead time of the ADC of 8100 CMA was shorter in the range up to 1000 channels. The temperature dependence was -0.017%/deg C in 8100 MCA, and -0.061 and -0.072%/deg C in GAMA. The long term stability was -0.02%/14 hr in 8100 MCA, and -0.027%/14 hr in 8060 of 1st GAMA. The derivative non-linearity was 0.45% in 8100 MCA, 0.67% in 8060 of 1st GAMA, and the integration non-linearity was 0.075% for 8100 MCA, and 0.085 - 0.1% in 8060 ADCs. Also, the change of γ peaks immediately after the power was turned on for 8100 ADC was better than that of 8060 ADC. (Wakatsuki, Y.)

  18. Can pretreatment ADC values predict recurrence of bladder cancer after transurethral resection?

    Energy Technology Data Exchange (ETDEWEB)

    Funatsu, Hiroyuki, E-mail: hirofunatsu999@hotmail.com [Division of Diagnostic Imaging, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Imamura, Akihiro; Takano, Hideyuki [Division of Diagnostic Imaging, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Ueda, Takeshi [Division of Urology, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Uno, Takashi [Department of Radiology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuou-ku, Chiba 260-8670 (Japan)

    2012-11-15

    Objective: The aim of this retrospective study was to investigate the association between the pretreatment apparent diffusion coefficient (ADC) value and recurrence of bladder cancer after transurethral resection. Methods: Patients with superficial bladder cancer were identified. Mean ADC values of the tumors were compared between patients with and without recurrence following trans-urethral resection. A receiver-operator characteristic curve was used for determining the optimal cutoff ADC value. Univariate and multivariate analyses were used to determine the effect of ADC values and other factors. Results: With a mean follow-up period of 25 months, bladder cancer recurred in 14 of 44 patients (32%). The mean ADC value of tumors in patients with recurrence was lower than in those without recurrence (1.08 mm{sup 2}/s vs. 1.28 Multiplication-Sign 10{sup -3} mm{sup 2}/s; p = 0.003). The optimal cutoff ADC value for predicting recurrence was determined to be 1.12 Multiplication-Sign 10{sup -3} mm{sup 2}/s. A modest and significant negative correlation was observed between the ADC values and tumor size (r = -0.436, p = 0.008). After adjustment for size and risk groups, an ADC value equal to or less than the optimal cutoff remained a significant predictor of recurrence (odds ratio 6.3, 95% CI 1.23-32.2, p = 0.027). Conclusion: Pretreatment ADC values may be an independent predictor of bladder cancer recurrence.

  19. Can pretreatment ADC values predict recurrence of bladder cancer after transurethral resection?

    International Nuclear Information System (INIS)

    Funatsu, Hiroyuki; Imamura, Akihiro; Takano, Hideyuki; Ueda, Takeshi; Uno, Takashi

    2012-01-01

    Objective: The aim of this retrospective study was to investigate the association between the pretreatment apparent diffusion coefficient (ADC) value and recurrence of bladder cancer after transurethral resection. Methods: Patients with superficial bladder cancer were identified. Mean ADC values of the tumors were compared between patients with and without recurrence following trans-urethral resection. A receiver–operator characteristic curve was used for determining the optimal cutoff ADC value. Univariate and multivariate analyses were used to determine the effect of ADC values and other factors. Results: With a mean follow-up period of 25 months, bladder cancer recurred in 14 of 44 patients (32%). The mean ADC value of tumors in patients with recurrence was lower than in those without recurrence (1.08 mm 2 /s vs. 1.28 × 10 −3 mm 2 /s; p = 0.003). The optimal cutoff ADC value for predicting recurrence was determined to be 1.12 × 10 −3 mm 2 /s. A modest and significant negative correlation was observed between the ADC values and tumor size (r = −0.436, p = 0.008). After adjustment for size and risk groups, an ADC value equal to or less than the optimal cutoff remained a significant predictor of recurrence (odds ratio 6.3, 95% CI 1.23–32.2, p = 0.027). Conclusion: Pretreatment ADC values may be an independent predictor of bladder cancer recurrence.

  20. Digitally assisted pipeline ADCs theory and implementation

    CERN Document Server

    Murmann, Boris

    2007-01-01

    List of Figures. List of Tables. Acknowledgements. Preface. 1: Introduction. 1. Motivation. 2. Overview. 3. Chapter Organization. 2: Performance Trends. 1. Introduction. 2. Digital Performance Trends. 3. ADC Performance Trends. 3: Scaling Analysis. 1. Introduction. 2. Basic Device Scaling from a Digital Perspective. 3. Technology Metrics for Analog Circuits. 4. Scaling Impact on Matching-Limited Circuits. 5. Scaling Impact on Noise-Limited Circuits. 4: Improving Analog Circuit Efficiency. 1. Introduction. 2. Analog Circuit Challenges. 3. The Cost of Feedback. 4. Two-Stage Feedback Amplifier vs. Open-Loop Gain Stage. 5. Discussion. 5: Open-Loop Pipelined ADCs. 1. A Brief Review of Pipelined ADCs. 2. Conventional Stage Implementation. 3. Open-Loop Pipeline Stages. 4. Alternative Transconductor Implementations. 6: Digital Nonlinearity Correction. 1. Overview. 2. Error Model and Digital Correction. 3. Alternative Error Models. 7: Statistics-Based Parameter Estimation. 1. Introduction. 2. Modulation Approach. 3. R...

  1. The use of MRI apparent diffusion coefficient (ADC) in monitoring the development of brain infarction

    International Nuclear Information System (INIS)

    Shen, Jian-Min; Xia, Xian-Wu; Kang, Wu-Gen; Yuan, Jian-Jun; Sheng, Liang

    2011-01-01

    To study the rules that apparent diffusion coefficient (ADC) changes with time and space in cerebral infarction, and to provide the evidence in defining the infarction stages. 117 work-ups in 98 patients with cerebral infarction (12 hyperacute, 43 acute, 29 subacute, 10 steady, and 23 chronic infarctions) were imaged with both conventional MRI and diffusion weighted imaging. The average ADC values, the relative ADC (rADC) values, and the ADC values or rADC values from the center to the periphery of the lesion were calculated. The average ADC values and the rADC values of hyperacute and acute infarction lesion depressed obviously. rADC values in hyperacute and acute stage was minimized, and increased progressively as time passed and appeared as 'pseudonormal' values in approximately 8 to 14 days. Thereafter, rADC values became greater than normal in chronic stage. There was positive correlation between rADC values and time (P < 0.01). The ADC values and the rADC values in hyperacute and acute lesions had gradient signs that these lesions increased from the center to the periphery. The ADC values and the rADC values in subacute lesions had adverse gradient signs that these lesions decreased from the center to the periphery. The ADC values of infarction lesions have evolution rules with time and space. The evolution rules with time and those in space can be helpful to decide the clinical stage, and to provide the evidence in guiding the treatment or judging the prognosis in infarction

  2. An ADC-free adaptive interface circuit of resistive sensor for electronic nose system.

    Science.gov (United States)

    Chang, Chia-Lin; Chiu, Shih-Wen; Tang, Kea-Tiong

    2013-01-01

    The initial resistance of chemiresistive gas sensors could be affected by temperature, humidity, and background odors. In a sensing system, the traditional interface circuit always requires an ADC to convert analog signal to digital signal. In this paper, we propose an ADC-free adaptive interface circuit for a resistive gas sensor to read sensor signal and cancel the baseline drift. Furthermore, methanol was used to test the proposed interface circuit, which was connected with a FIGARO® gas sensor. This circuit was fabricated by TSMC 0.18 µm CMOS process, and consumed 86.41 µW under 1 V supply voltage.

  3. Photoluminescence detection of alpha particle using DAM-ADC nuclear detector

    Energy Technology Data Exchange (ETDEWEB)

    Abdalla, Ayman M., E-mail: aymanabdalla62@hotmail.com [Department of Physics, College of Science and Arts, Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, P.O. Box: 1988, Najran 11001 (Saudi Arabia); Harraz, Farid A., E-mail: fharraz68@yahoo.com [Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, P.O. Box: 1988, Najran 11001 (Saudi Arabia); Nanostructured Materials and Nanotechnology Division, Central Metallurgical Research and Development Institute (CMRDI), P.O. Box: 87 Helwan, Cairo 11421 (Egypt); Ali, Atif M. [Department of Physics, Faculty of Science, King Khalid University, Abha (Saudi Arabia); Al-Sayari, S.A. [Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, P.O. Box: 1988, Najran 11001 (Saudi Arabia); College of Science and Arts-Sharoura, Najran University (Saudi Arabia); Al-Hajry, A. [Department of Physics, College of Science and Arts, Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, P.O. Box: 1988, Najran 11001 (Saudi Arabia)

    2016-09-11

    The photoluminescence (PL) and UV–vis spectral analysis of DAM-ADC (diallyl maleate: DAM, polyallyl diglycol carbonate: ADC) nuclear detector are demonstrated for the first time. The DAM-ADC surfaces were exposed to thin {sup 241}Am disk source that emits alpha particles with activity 333 kBq. It is found that the track density of the irradiated samples remarkably influences the PL characteristics of the DAM-ADC detector. The spectral peak heights and the integrated intensities under the peaks exhibit linear correlations with correlation coefficient R{sup 2}=0.9636 and 0.9806, respectively for different alpha particle fluences ranging from 8.16–40.82×10{sup 7} particles/cm{sup 2}. Additionally, a correlation coefficient R{sup 2}=0.9734 was achieved for the UV–vis spectral analysis. The linear fitting functions, along with the corresponding fitting parameters were evaluated in each case. Both the PL and the UV–vis data of the irradiated DAM-ADC samples showed considerable spectral differences, and hence they would be used to offer sensitive approaches for alpha particle detection.

  4. Diffusion-weighted MR imaging and ADC mapping in differentiating benign from malignant thyroid nodules

    International Nuclear Information System (INIS)

    Khizer, A.T.; Slehria, A.U.R.

    2015-01-01

    To determine the diagnostic accuracy of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping in differentiating benign from malignant thyroid nodules by taking histopathology as the gold standard. Study Design:Across-sectional analytical study. Place and Duration of Study: Department of Radiology at Combined Military Hospital (CMH), Lahore, from August 2012 to July 2013. Methodology: Thirty-five patients, who were referred to radiology department of CMH, Lahore, for ultrasound or Fine Needle Aspiration Cytology (FNAC) of thyroid gland, fulfilling the inclusion and exclusion criteria, were included in the study. They were evaluated on 1.5 Tesla MRI machine with T1- and T2-weighted imaging as well as fat-suppressed technique. DWI was done using b-values of 0 and 1000 s/mm2 and ADC values were calculated for the thyroid nodules. All of these patients were subjected to ultrasound guided core biopsy and histopathology results were correlated with ADC values. Results: The benign nodules showed facilitated diffusion while malignant nodules showed restricted diffusion. T-test was used to assess the difference in mean ADC values between benign and malignant nodules. The mean ADC value of the malignant thyroid nodules (0.94 ± 0.16 x 10/sup -3/mm2/s) was significantly lower than that of the benign thyroid nodules (1.93 ±0.13 x 10/sup -3/mm2/s) (p-value < 0.05). ADC value of 1.6 x 10/sup -3/mm2/s was used as a cut-off, for differentiating benign from malignant thyroid nodules. The sensitivity, specificity, PPV, NPV and diagnostic accuracy of DWI and ADC values in differentiating benign from malignant thyroid nodules were 93%, 95%, 93%, 95% and 92.3%, respectively. Conclusion: DWI is a non-invasive diagnostic tool for characterization and differentiation between benign and malignant thyroid nodules. It not only decreases the burden of unnecessary surgeries when pre-operative FNAC and biopsy are inconclusive, but is also helpful in reaching a

  5. Improved low-distortion sigma-delta ADC with DWA for WLAN standards

    Energy Technology Data Exchange (ETDEWEB)

    Li Di; Yang Yintang; Zhu Zhangming; Shi Lichun; Wu Xiaofeng; Wang Jiangan, E-mail: lidi2004@126.co [School of Microelectronics, Xidian University, Xi' an 710071 (China)

    2010-02-15

    An improved low distortion sigma-delta ADC (analog-to-digital converter) for wireless local area network standards is presented. A feed-forward MASH 2-2 multi-bit cascaded sigma-delta ADC is adopted; however, this work shows a much better performance than the ADCs which have been presented to date by adding a feedback factor in the second stage to improve the performance of the in-band SNDR (signal to noise and distortion ratio), using 4-bit ADCs in both stages to minimize the quantization noise. Data weighted averaging technology is therefore used to decrease the mismatch noise induced by the 4-bit DACs, which improves the SFDR (spurious free dynamic range) of the ADC. The modulator has been implemented by a 0.18 {mu}m CMOS process and operates at a single 1.8 V supply voltage. Experimental results show that for a 1.25 MHz - -6 dBFS input signal at 160 MHz sampling frequency, the improved ADC with all non-idealities considered achieves a peak SNDR of 80.9 dB and an SFDR of 87 dB, and the effective number of bits is 13.15 bits. (semiconductor integrated circuits)

  6. High power-efficient asynchronous SAR ADC for IoT devices

    Science.gov (United States)

    Zhang, Beichen; Yao, Bingbing; Liu, Liyuan; Liu, Jian; Wu, Nanjian

    2017-10-01

    This paper presents a power-efficient 100-MS/s, 10-bit asynchronous successive approximation register (SAR) ADC. It includes an on-chip reference buffer and the total power dissipation is 6.8 mW. To achieve high performance with high power-efficiency in the proposed ADC, bootstrapped switch, redundancy, set-and-down switching approach, dynamic comparator and dynamic logic techniques are employed. The prototype was fabricated using 65 nm standard CMOS technology. At a 1.2-V supply and 100 MS/s, the ADC achieves an SNDR of 56.2 dB and a SFDR of 65.1 dB. The ADC core consumes only 3.1 mW, resulting in a figure of merit (FOM) of 30.27 fJ/conversionstep and occupies an active area of only 0.009 mm2.

  7. The use of MRI apparent diffusion coefficient (ADC in monitoring the development of brain infarction

    Directory of Open Access Journals (Sweden)

    Yuan Jian-Jun

    2011-01-01

    Full Text Available Abstract Background To study the rules that apparent diffusion coefficient (ADC changes with time and space in cerebral infarction, and to provide the evidence in defining the infarction stages. Methods 117 work-ups in 98 patients with cerebral infarction (12 hyperacute, 43 acute, 29 subacute, 10 steady, and 23 chronic infarctions were imaged with both conventional MRI and diffusion weighted imaging. The average ADC values, the relative ADC (rADC values, and the ADC values or rADC values from the center to the periphery of the lesion were calculated. Results The average ADC values and the rADC values of hyperacute and acute infarction lesion depressed obviously. rADC values in hyperacute and acute stage was minimized, and increased progressively as time passed and appeared as "pseudonormal" values in approximately 8 to 14 days. Thereafter, rADC values became greater than normal in chronic stage. There was positive correlation between rADC values and time (P Conclusion The ADC values of infarction lesions have evolution rules with time and space. The evolution rules with time and those in space can be helpful to decide the clinical stage, and to provide the evidence in guiding the treatment or judging the prognosis in infarction.

  8. Low Power Continuous-Time Delta-Sigma ADC with Current Output DAC

    DEFF Research Database (Denmark)

    Marker-Villumsen, Niels; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2015-01-01

    The paper presents a continuous-time (CT) DeltaSigma (∆Σ) analog-to-digital converter (ADC) using a current output digital-to-analog converter (DAC) for the feedback. From circuit analysis it is shown that using a current output DAC makes it possible to relax the noise requirements of the 1st...... integrator of the loopfilter, and thereby reduce the current consumption. Furthermore, the noise of the current output DAC being dependent on the ADC input signal level, enabling a dynamic range that is larger than the peak signal-to-noise ratio (SNR). The current output DAC is used in a 3rd order multibit...... CT ∆Σ ADC for audio applications, designed in a 0.18 µm CMOS process, with active-RC integrators, a 7-level Flash ADC quantizer and current output DAC for the feedback. From simulations the ADC achieves a dynamic range of 95.0 dB in the audio band, with a current consumption of 284 µA for a 1.7 V...

  9. Development of a Multichannel Analyzer for modular ADCs

    International Nuclear Information System (INIS)

    Bannos Rodriguez, U.; Diaz Castro, M.; Rivero Ramirez, D.

    2013-01-01

    This paper describes the design and construction of a multichannel analyzer with USB interface from ADC module of the Fast ComTec 7074. One PIC18F4550 microprocessor from Microchip, one CPLD isPLSI 1032E from Lattice and one 32Kx8 SRAM memory were used. It also includes details of the programming circuitry and development of program acquisition, storage and display of the spectra using the Qt libraries. Finally, preliminary tests to the device are show. (Author)

  10. Normal cranial bone marrow MR imaging pattern with age-related ADC value distribution

    International Nuclear Information System (INIS)

    Li Qi; Pan Shinong; Yin Yuming; Li Wei; Chen Zhian; Liu Yunhui; Wu Zhenhua; Guo Qiyong

    2011-01-01

    Objective: To determine MRI appearances of normal age-related cranial bone marrow and the relationship between MRI patterns and apparent diffusion coefficient (ADC) values. Methods: Five hundred subjects were divided into seven groups based on ages. Cranial bone marrow MRI patterns were performed based on different thickness of the diploe and signal intensity distribution characteristics. ADC values of the frontal, parietal, occipital and temporal bones on DWI were measured and calculated. Correlations between ages and ADC values, between patterns and ADC values, as well as the distribution of ADC values were analyzed. Results: Normal cranial bone marrow was divided into four types and six subtypes, Type I, II, III and IV, which had positive correlation with age increasing (χ 2 = 266.36, P 0.05). In addition, there was significant negative correlation between the ADC values and MRI patterns in the normal parietal and occipital bones (r = -0.691 and -0.750, P < 0.01). Conclusion: The combination of MRI features and ADC values changes in different cranial bones showed significant correlation with age increasing. Familiar with the MRI appearance of the normal bone marrow conversion pattern in different age group and their ADC value will aid the diagnosis and differential of the cranial bone pathology.

  11. Semi-autonomous controller for data acquisition, the Brilliant ADC

    International Nuclear Information System (INIS)

    Breidenbach, M.; Frank, E.; Hall, J.; Nelson, D.

    1977-10-01

    A set of high speed 16-bit computers and ADC's designed and built for the data collection, compression, and correction system of the SLAC/LBL Mark II Magnetic Detector. The ''Brilliant ADC'' controls the analog multiplexing of a CAMAC crate of data acquisition modules, digitizes the analog data, and executes microprogrammed algorithms for data handling and correction

  12. A low-power and small-area column-level ADC for high frame-rate CMOS pixel sensor

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, L., E-mail: liang.zhang@iphc.cnrs.fr [School of Physics, Key Laboratory of Particle Physics and Particle Irradiation, Shandong University, 250100 Jinan (China); Institut Pluridisciplinaire Hubert Curien, University of Strasbourg, CNRS/IN2P3/UDS, 23 rue du loess, BP 28, 67037 Strasbourg (France); Morel, F.; Hu-Guo, C.; Hu, Y. [Institut Pluridisciplinaire Hubert Curien, University of Strasbourg, CNRS/IN2P3/UDS, 23 rue du loess, BP 28, 67037 Strasbourg (France)

    2014-07-01

    CMOS pixel sensors (CPS) have demonstrated performances meeting the specifications of the International Linear Collider (ILC) vertex detector (VTX). This paper presents a low-power and small-area 4-bit column-level analog-to-digital converter (ADC) for CMOS pixel sensors. The ADC employs a self-timed trigger and completes the conversion by performing a multi-bit/step approximation. As in the outer layers of the ILC vertex detector hit density is of the order of a few per thousand, in order to reduce power consumption, the ADC is designed to work in two modes: active mode and idle mode. The ADC is fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. It is implemented with 48 columns in a sensor prototype. Each column ADC covers an area of 35 ×545 μm{sup 2}. The measured temporal noise and Fixed Pattern Noise (FPN) are 0.96 mV and 0.40 mV, respectively. The power consumption, for a 3 V supply and 6.25 MS/s sampling rate, is 486 μW during idle time, which is by far the most frequently employed one. This value rises to 714 μW in the case of the active mode. The measured differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.49/−0.28 LSB and 0.29/−0.20 LSB, respectively. - Highlights: • CMOS sensor integrated with column-level ADC is proposed for ILC VTX outer layers. • A low-power and small-area column-level ADC for high frame-rate CPS is presented. • The test results demonstrate the power and area efficiency. • The architecture is suitable for the outer layer CMOS sensors.

  13. A low-power and small-area column-level ADC for high frame-rate CMOS pixel sensor

    International Nuclear Information System (INIS)

    Zhang, L.; Morel, F.; Hu-Guo, C.; Hu, Y.

    2014-01-01

    CMOS pixel sensors (CPS) have demonstrated performances meeting the specifications of the International Linear Collider (ILC) vertex detector (VTX). This paper presents a low-power and small-area 4-bit column-level analog-to-digital converter (ADC) for CMOS pixel sensors. The ADC employs a self-timed trigger and completes the conversion by performing a multi-bit/step approximation. As in the outer layers of the ILC vertex detector hit density is of the order of a few per thousand, in order to reduce power consumption, the ADC is designed to work in two modes: active mode and idle mode. The ADC is fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. It is implemented with 48 columns in a sensor prototype. Each column ADC covers an area of 35 ×545 μm 2 . The measured temporal noise and Fixed Pattern Noise (FPN) are 0.96 mV and 0.40 mV, respectively. The power consumption, for a 3 V supply and 6.25 MS/s sampling rate, is 486 μW during idle time, which is by far the most frequently employed one. This value rises to 714 μW in the case of the active mode. The measured differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.49/−0.28 LSB and 0.29/−0.20 LSB, respectively. - Highlights: • CMOS sensor integrated with column-level ADC is proposed for ILC VTX outer layers. • A low-power and small-area column-level ADC for high frame-rate CPS is presented. • The test results demonstrate the power and area efficiency. • The architecture is suitable for the outer layer CMOS sensors

  14. Brookhaven FASTBUS ADC's

    International Nuclear Information System (INIS)

    Schmidt, M.P.; Black, J.K.; Blatt, S.R.

    1983-01-01

    A high energy physics experiment has been performed at Brookhaven National Laboratory on k/sub L/ 0 → 2π 0 decays employing a large (> 200 element) lead glass array as an electromagnetic calorimeter. To acquire pulse height information from the detector we have constructed ADC modules in the context of the Brookhaven Fastbus data acquisition system. Digitization (8 bits) and encoding, including pedestal subtraction and data sparsing, is achieved for each 16 channel module in 6 μsec

  15. A robust and simple two-mode digital calibration technique for pipelined ADC

    Energy Technology Data Exchange (ETDEWEB)

    Yin Xiumei; Zhao Nan; Sekedi Bomeh Kobenge; Yang Huazhong, E-mail: yxm@mails.tsinghua.edu.cn [Department of Electronic Engineering, Tsinghua University, Beijing 100084 (China)

    2011-03-15

    This paper presents a two-mode digital calibration technique for pipelined analog-to-digital converters (ADC). The proposed calibration eliminates the errors of residual difference voltage induced by capacitor mismatch of pseudorandom (PN) sequence injection capacitors at the ADC initialization, while applies digital background calibration to continuously compensate the interstage gain errors in ADC normal operation. The presented technique not only reduces the complexity of analog circuit by eliminating the implementation of PN sequence with accurate amplitude in analog domain, but also improves the performance of digital background calibration by minimizing the sensitivity of calibration accuracy to sub-ADC errors. The use of opamps with low DC gains in normal operation makes the proposed design more compatible with future nanometer CMOS technology. The prototype of a 12-bit 40-MS/s pipelined ADC with the two-mode digital calibration is implemented in 0.18-{mu}m CMOS process. Adopting a simple telescopic opamp with a DC gain of 58-dB in the first stage, the measured SFDR and SNDR within the first Nyquist zone reach 80-dB and 66-dB, respectively. With the calibration, the maximum integral nonlinearity (INL) of the ADC reduces from 4.75-LSB to 0.65-LSB, while the ADC core consumes 82-mW at 3.3-V power supply. (semiconductor integrated circuits)

  16. A Contribution to Nyquist-Rate ADC Modeling - Detailed Algorithm Description

    Directory of Open Access Journals (Sweden)

    J. Zidek

    2012-04-01

    Full Text Available In this article, the innovative ADC modeling algorithm is described. It is well suitable for nyquist-rate ADC error back annotation. This algorithm is the next step of building a support tool for IC design engineers. The inspiration for us was the work [2]. Here, the ADC behavior is divided into HCF (High Code Frequency and LCF (Low Code Frequency separated independent parts. This paper is based on the same concept but the model coefficients are estimated in a different way only from INL data. The HCF order recognition part was newly added as well. Thanks to that the HCF coefficients number is lower in comparison with the original Grimaldi’s work (especially for converters with low ratio between HCF and “random” part of INL. Modeling results are demonstrated on a real data set measured by ASICentrum on chargeredistribution type SAR ADC chip. Results are showed not only by coefficient values but also by the Model Coverage metrics. Model limitations are also discussed.

  17. Histogram analysis derived from apparent diffusion coefficient (ADC) is more sensitive to reflect serological parameters in myositis than conventional ADC analysis.

    Science.gov (United States)

    Meyer, Hans Jonas; Emmer, Alexander; Kornhuber, Malte; Surov, Alexey

    2018-05-01

    Diffusion-weighted imaging (DWI) has the potential of being able to reflect histopathology architecture. A novel imaging approach, namely histogram analysis, is used to further characterize tissues on MRI. The aim of this study was to correlate histogram parameters derived from apparent diffusion coefficient (ADC) maps with serological parameters in myositis. 16 patients with autoimmune myositis were included in this retrospective study. DWI was obtained on a 1.5 T scanner by using the b-values of 0 and 1000 s mm - 2 . Histogram analysis was performed as a whole muscle measurement by using a custom-made Matlab-based application. The following ADC histogram parameters were estimated: ADCmean, ADCmax, ADCmin, ADCmedian, ADCmode, and the following percentiles ADCp10, ADCp25, ADCp75, ADCp90, as well histogram parameters kurtosis, skewness, and entropy. In all patients, the blood sample was acquired within 3 days to the MRI. The following serological parameters were estimated: alanine aminotransferase, aspartate aminotransferase, creatine kinase, lactate dehydrogenase, C-reactive protein (CRP) and myoglobin. All patients were screened for Jo1-autobodies. Kurtosis correlated inversely with CRP (p = -0.55 and 0.03). Furthermore, ADCp10 and ADCp90 values tended to correlate with creatine kinase (p = -0.43, 0.11, and p = -0.42, = 0.12 respectively). In addition, ADCmean, p10, p25, median, mode, and entropy were different between Jo1-positive and Jo1-negative patients. ADC histogram parameters are sensitive for detection of muscle alterations in myositis patients. Advances in knowledge: This study identified that kurtosis derived from ADC maps is associated with CRP in myositis patients. Furthermore, several ADC histogram parameters are statistically different between Jo1-positive and Jo1-negative patients.

  18. PI-RADS v2 and ADC values: is there room for improvement?

    Science.gov (United States)

    Jordan, Eric J; Fiske, Charles; Zagoria, Ronald; Westphalen, Antonio C

    2018-03-17

    To determine the diagnostic accuracy of ADC values in combination with PI-RADS v2 for the diagnosis of clinically significant prostate cancer (CS-PCa) compared to PI-RADS v2 alone. This retrospective study included 155 men whom underwent 3-Tesla prostate MRI and subsequent MR/US fusion biopsies at a single non-academic center from 11/2014 to 3/2016. All scans were performed with a surface coil and included T2, diffusion-weighted, and dynamic contrast-enhanced sequences. Suspicious findings were classified using Prostate Imaging Reporting and Data System (PI-RADS) v2 and targeted using MR/US fusion biopsies. Mixed-effect logistic regression analyses were used to determine the ability of PIRADS v2 alone and combined with ADC values to predict CS-PCa. As ADC categories are more practical in clinical situations than numeric values, an additional model with ADC categories of ≤ 800 and > 800 was performed. A total of 243 suspicious lesions were included, 69 of which were CS-PCa, 34 were Gleason score 3+3 PCa, and 140 were negative. The overall PIRADS v2 score, ADC values, and ADC categories are independent statistically significant predictors of CS-PCa (p values or categories is better discrimination of PI-RADS v2 4 lesions. ADC values and categories help to diagnose CS-PCa when lesions are assigned a PI-RADS v2 score of 4.

  19. Antibody-Drug Conjugates (ADCs) for Personalized Treatment of Solid Tumors: A Review.

    Science.gov (United States)

    Lambert, John M; Morris, Charles Q

    2017-05-01

    Attaching a cytotoxic "payload" to an antibody to form an antibody-drug conjugate (ADC) provides a mechanism for selective delivery of the cytotoxic agent to cancer cells via the specific binding of the antibody to cancer-selective cell surface molecules. The first ADC to receive marketing authorization was gemtuzumab ozogamicin, which comprises an anti-CD33 antibody conjugated to a highly potent DNA-targeting antibiotic, calicheamicin, approved in 2000 for treating acute myeloid leukemia. It was withdrawn from the US market in 2010 following an unsuccessful confirmatory trial. The development of two classes of highly potent microtubule-disrupting agents, maytansinoids and auristatins, as payloads for ADCs resulted in approval of brentuximab vedotin in 2011 for treating Hodgkin lymphoma and anaplastic large cell lymphoma, and approval of ado-trastuzumab emtansine in 2013 for treating HER2-positive breast cancer. Their success stimulated much research into the ADC approach, with >60 ADCs currently in clinical evaluation, mostly targeting solid tumors. Five ADCs have advanced into pivotal clinical trials for treating various solid tumors-platinum-resistant ovarian cancer, mesothelioma, triple-negative breast cancer, glioblastoma, and small cell lung cancer. The level of target expression is a key parameter in predicting the likelihood of patient benefit for all these ADCs, as well as for the approved compound, ado-trastuzumab emtansine. The development of a patient selection strategy linked to target expression on the tumor is thus critically important for identifying the population appropriate for receiving treatment.

  20. Regional ADC values of the normal brain: differences due to age, gender, and laterality.

    Science.gov (United States)

    Naganawa, Shinji; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo; Ishigaki, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean+/-standard deviation 2.3+/-1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (pright frontal, bilateral thalamus, and temporal (pbrain and may be useful for the future quantitative study as a reference.

  1. Design and development of CAMAC 12 bit ADC/DAC dual purpose module

    International Nuclear Information System (INIS)

    Kulkarni, S.G.; Gore, J.A.; Ramlal, V.; Matkar, U.V.; Lokare, R.N.; Yadav, M.L.; Ekambaram, M.; Gupta, A.K.; Datar, V.M.

    2013-01-01

    A dual function CAMAC module is designed for Pelletron Accelerator which can function as 12 bit 8 channels DAC or 12 bit 16 channels ADC. Spartan 2 series of FPGA is used for implementing the CAMAC interface logic as well as logic for ADC/DAC interface. The PCB has both the ADC and DAC mounted but the module can have only one function selected due to wiring constraint. Two different VHDL programs (one for the ADC and other for the DAC) reside on the EEPROM permitting selection of any one as per the functionality required. The module is working as a 12 bit DAC at BARC-TIFR Pelletron Linac Facility, successfully. (author)

  2. Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values.

    Science.gov (United States)

    Thörmer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe; Horn, Lars-Christian; Kahn, Thomas; Busse, Harald

    2012-08-01

    To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm(2)) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS= 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. • Absolute ADC values are highly dependent on the choice of b values. • Absolute ADC thresholds should be used carefully to predict tumour aggressiveness. • Subjective ratings of ADC maps involving b = 0 s/mm ( 2 ) are poor to fair. • Minimum b value greater than 0 s/mm ( 2 ) is recommended for ADC calculation.

  3. CUSTOMER PERCEPTION ON ALTERNATIVE DELIVERY CHANNEL (ADC OF BANKS IN BANGLADESH

    Directory of Open Access Journals (Sweden)

    Shahed BIN SADIQUE

    2016-12-01

    Full Text Available This paper aims at understanding the level of customer’s perception on alternative delivery channel of different commercial schedule banks of Bangladesh. Considering the significant development in technology and for sustainability, banking industry in Bangladesh has expanded banking operation through offering different ADCs to attract customers which are ultimately changing the perception of customers in the long run. Based on this reality, data were collected from a survey and a usable sample of 134 was taken for analysis. KAPPA test and multiple regression model is used to analyze the overall consistency of respondent’s responses and measurement of consumers’ perception. The results of the survey show that visibility, availability, self-security, confidential transaction ability, easiness and simplicity in the procedure of ADC makes it more attractive to consumer. The findings also suggest that security of physical establishment of ADC is vital though banks have given less importance to it. From the study, it is found that in order to change perception and to attract more users to banking; it is not going to be enough to make the system easy to interact with. Banks should develop more secured and private alternative delivery channels that will be reliable to their customers. Thus, management attention might be effectively focused on the development of such sectors that have been properly identified in this research.

  4. Customer Perception on Alternative Delivery Channel (ADC of Banks in Bangladesh

    Directory of Open Access Journals (Sweden)

    Shahed BIN SADIQUE

    2016-12-01

    Full Text Available This paper aims at understanding the level of customer’s perception on alternative delivery channel of different commercial schedule banks of Bangladesh. Considering the significant development in technology and for sustainability, banking industry in Bangladesh has expanded banking operation through offering different ADCs to attract customers which are ultimately changing the perception of customers in the long run. Based on this reality, data were collected from a survey and a usable sample of 134 was taken for analysis. KAPPA test and multiple regression model is used to analyze the overall consistency of respondent’s responses and measurement of consumers’ perception. The results of the survey show that visibility, availability, self-security, confidential transaction ability, easiness and simplicity in the procedure of ADC makes it more attractive to consumer. The findings also suggest that security of physical establishment of ADC is vital though banks have given less importance to it. From the study, it is found that in order to change perception and to attract more users to banking; it is not going to be enough to make the system easy to interact with. Banks should develop more secured and private alternative delivery channels that will be reliable to their customers. Thus, management attention might be effectively focused on the development of such sectors that have been properly identified in this research.

  5. Changes in ADC Caused by Tensile Loading of Rabbit Achilles Tendon: Evidence for Water Transport

    Science.gov (United States)

    Han, S.; Gemmell, S. J.; Helmer, K. G.; Grigg, P.; Wellen, J. W.; Hoffman, A. H.; Sotak, C. H.

    2000-06-01

    Water diffusion measurements were performed on rabbit Achilles tendons during static tensile loading and tendons in an unloaded state. The apparent diffusion coefficient (ADC) was measured along two directions: parallel and perpendicular to the long axis of the tendon. Tendons were studied after being prepared in two ways: (a) after being stored frozen in phosphate-buffered saline (PBS) and (b) freshly isolated. Statistically significant directional anisotropy was observed in the ADC in all tendons. The ADC was significantly greater in the direction parallel to the long axis of the tendon than in the perpendicular direction. The anisotropy is attributed to the greater restrictions seen by the water molecules in the perpendicular direction and is consistent with the known geometry of the tendon. Storage in PBS caused tendons to swell. This increased the ADC measured along both directions and reduced the anisotropy. The existence of anisotropy in the ADC was not related to the orientation of the specimen in the magnet. The ADC increased along both directions following the application of a 5-N tensile load; the increase was greatest along the perpendicular axis of the tendon. In order to determine whether load-related changes in the ADC reflected changes in interfibrilar spacing, we used electron microscopy to measure load-related changes in fibril spacing. Load-related changes in fiber spacing could not account for the observed changes in the ADC. The increase in ADC caused by loading was attributed to the extrusion of tendon water into a bulk phase along the outside surface of the tendon. In PBS-stored samples, enough fluid was extruded that it could be visualized. The transient response of the ADC to a 5-N tensile load was also studied. The absolute ADC in both directions increased with loading and recovered to baseline upon unloading. The transient changes in ADC, for both loading and unloading, had a mean time constant of approximately 15 min. The magnitude of

  6. A 10-bit column-parallel cyclic ADC for high-speed CMOS image sensors

    International Nuclear Information System (INIS)

    Han Ye; Li Quanliang; Shi Cong; Wu Nanjian

    2013-01-01

    This paper presents a high-speed column-parallel cyclic analog-to-digital converter (ADC) for a CMOS image sensor. A correlated double sampling (CDS) circuit is integrated in the ADC, which avoids a stand-alone CDS circuit block. An offset cancellation technique is also introduced, which reduces the column fixed-pattern noise (FPN) effectively. One single channel ADC with an area less than 0.02 mm 2 was implemented in a 0.13 μm CMOS image sensor process. The resolution of the proposed ADC is 10-bit, and the conversion rate is 1.6 MS/s. The measured differential nonlinearity and integral nonlinearity are 0.89 LSB and 6.2 LSB together with CDS, respectively. The power consumption from 3.3 V supply is only 0.66 mW. An array of 48 10-bit column-parallel cyclic ADCs was integrated into an array of CMOS image sensor pixels. The measured results indicated that the ADC circuit is suitable for high-speed CMOS image sensors. (semiconductor integrated circuits)

  7. A 0.9-V 12-bit 40-MSPS Pipeline ADC for Wireless Receivers

    Science.gov (United States)

    Ito, Tomohiko; Itakura, Tetsuro

    A 0.9-V 12-bit 40-MSPS pipeline ADC with I/Q amplifier sharing technique is presented for wireless receivers. To achieve high linearity even at 0.9-V supply, the clock signals to sampling switches are boosted over 0.9V in conversion stages. The clock-boosting circuit for lifting these clocks is shared between I-ch ADC and Q-ch ADC, reducing the area penalty. Low supply voltage narrows the available output range of the operational amplifier. A pseudo-differential (PD) amplifier with two-gain-stage common-mode feedback (CMFB) is proposed in views of its wide output range and power efficiency. This ADC is fabricated in 90-nm CMOS technology. At 40MS/s, the measured SNDR is 59.3dB and the corresponding effective number of bits (ENOB) is 9.6. Until Nyquist frequency, the ENOB is kept over 9.3. The ADC dissipates 17.3mW/ch, whose performances are suitable for ADCs for mobile wireless systems such as WLAN/WiMAX.

  8. Comparison of ADC values in different malignancies of the skeletal musculature: a multicentric analysis

    International Nuclear Information System (INIS)

    Surov, Alexey; Nagata, Shuji; Razek, Ahmed A. Abd; Tirumani, Sree Harsha; Wienke, Andreas; Kahn, Thomas

    2015-01-01

    Diffusion-weighted imaging (DWI) provides essential information regarding tumor composition, such as cellularity and/or perfusion. DWI is helpful in distinguishing between malignant and benign lesions. Malignant intramuscular/soft tissue lesions consist of a wide spectrum of tumors that have different cell counts and matrix. It is presumed that these different tumors have different DWI findings and have different apparent diffusion coefficient (ADC) values. The aim of this study was to analyze DWI findings of different intramuscular malignancies in a multicentric study by using a standardized DWI protocol, and to compare the ADC values acquired. The data banks of four radiology departments were screened retrospectively for malignant intramuscular tumors. Only lesions that were investigated by MRI (with a 1.5-T scanner) using DWI (multishot EPI sequence with b values of 0 and 1,000 s/mm 2 ) were included in the study. Overall, 51 patients (28 women, 23 men; mean age 58.8 ± 16.1 years) with 57 different malignant intramuscular lesions were collected. In every case apparent diffusion constant (ADC) maps were calculated. In 14 patients muscle lymphoma, 11 patients intramuscular metastases from different primary tumors, and in 26 cases several muscle sarcomas were identified. The mean ADC value of the estimated lesions was 1.24 ± 0.53 x 10 -3 mm 2 s -1 , median value, 1.11 x 10 -3 mm 2 s -1 , range, 0.54-2.9 x 10 -3 mm 2 s -1 . The mean ADC value in muscle metastases was 1.28 ± 0.24 x 10 -3 mm 2 s -1 , in muscle lymphoma 0.76 ± 0.14 x 10 -3 mm 2 s -1 , and in muscle sarcomas 1.82 ± 0.63 x 10 -3 mm 2 s -1 . Muscle lymphoma showed statistically significant lower ADC values in comparison to muscle metastases (p = 0.01) and muscle sarcoma (p = 0.001). There was no significant differences between ADC values in muscle metastases and sarcomas (p = 0.48). ADC values in muscle lymphoma were homogeneous with less inter-patient variability and were within a relatively close

  9. Comparison of ADC values in different malignancies of the skeletal musculature: a multicentric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Surov, Alexey [Martin-Luther-University Halle-Wittenberg, Department of Radiology, Halle (Germany); University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Nagata, Shuji [Kurume University School of Medicine, Department of Radiology, Kurume (Japan); Razek, Ahmed A. Abd [Mansoura Faculty of Medicine, Department of Diagnostic Radiology, Mansoura (Egypt); Tirumani, Sree Harsha [Harvard Medical School, Department of Imaging, Dana-Farber Cancer Institute and Department of Radiology, Brigham and Women' s Hospital, Boston, MA (United States); Wienke, Andreas [Martin-Luther-University Halle-Wittenberg, Institute of Medical Epidemiology, Biometry, and Statistics, Halle (Germany); Kahn, Thomas [University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany)

    2015-04-28

    Diffusion-weighted imaging (DWI) provides essential information regarding tumor composition, such as cellularity and/or perfusion. DWI is helpful in distinguishing between malignant and benign lesions. Malignant intramuscular/soft tissue lesions consist of a wide spectrum of tumors that have different cell counts and matrix. It is presumed that these different tumors have different DWI findings and have different apparent diffusion coefficient (ADC) values. The aim of this study was to analyze DWI findings of different intramuscular malignancies in a multicentric study by using a standardized DWI protocol, and to compare the ADC values acquired. The data banks of four radiology departments were screened retrospectively for malignant intramuscular tumors. Only lesions that were investigated by MRI (with a 1.5-T scanner) using DWI (multishot EPI sequence with b values of 0 and 1,000 s/mm{sup 2}) were included in the study. Overall, 51 patients (28 women, 23 men; mean age 58.8 ± 16.1 years) with 57 different malignant intramuscular lesions were collected. In every case apparent diffusion constant (ADC) maps were calculated. In 14 patients muscle lymphoma, 11 patients intramuscular metastases from different primary tumors, and in 26 cases several muscle sarcomas were identified. The mean ADC value of the estimated lesions was 1.24 ± 0.53 x 10{sup -3} mm{sup 2}s{sup -1}, median value, 1.11 x 10{sup -3} mm{sup 2}s{sup -1}, range, 0.54-2.9 x 10{sup -3} mm{sup 2}s{sup -1}. The mean ADC value in muscle metastases was 1.28 ± 0.24 x 10{sup -3} mm{sup 2}s{sup -1}, in muscle lymphoma 0.76 ± 0.14 x 10{sup -3} mm{sup 2}s{sup -1}, and in muscle sarcomas 1.82 ± 0.63 x 10{sup -3} mm{sup 2}s{sup -1}. Muscle lymphoma showed statistically significant lower ADC values in comparison to muscle metastases (p = 0.01) and muscle sarcoma (p = 0.001). There was no significant differences between ADC values in muscle metastases and sarcomas (p = 0.48). ADC values in muscle lymphoma were

  10. 14-bit 100 MS/s 121 mW pipelined ADC

    International Nuclear Information System (INIS)

    Chen Yongzhen; Chen Chixiao; Feng Zemin; Ye Fan; Ren Junyan

    2015-01-01

    This paper presents a high-speed high-resolution pipelined ADC with low power and small area. The proposed ADC is designed based on the analysis of the stage scaling theory and the residual amplifiers are shared by two cascading MDACs to reduce power consumption. Shared op-amps with two split input paths are presented in this paper to eliminate the nonlinearity effects such as memory effect and crosstalk. Dynamic pre-amplified comparators are employed to decrease the static power consumption and suppress the kick-back in the comparators. This ADC is implemented in SMIC 0.18 μm CMOS process with an area of 3.1 mm 2 . With a sampling rate of 100 MS/s, spurious-free dynamic range (SFDR) and signal-to-noise plus distortion ratio (SNDR) of the ADC are 82.7 dB and 69.1 dB, respectively. For signals up to 100 MHz, the SFDR and SNDR achieve 81.4 dB and 65.8 dB. The power consumption is 121 mW with a 1.8 V supply voltage. (paper)

  11. A 10MS/s 8-bit charge-redistribution ADC for hybrid pixel applications in 65m CMOS

    CERN Document Server

    Kishishita, T; Krüger, H; Koch, M; Germic, L; Wermes, N

    2013-01-01

    The design and measurement results of an 8-bit SAR ADC, based on a charge-redistribution DAC, are presented. This ADC is characterized by superior power efficiency and small area, realized by employing a lateral metal–metal capacitor array and a dynamic two-stage comparator. To avoid the need for a highspeed clock and its associated power consumption, an asynchronous logic was implemented in a logic control cell. A test chip has been developed in a 65 nm CMOS technology, including eight ADC channels with different layout flavors of the capacitor array, a transimpedance amplifier as a signal input structure, a serializer, and a custom-made LVDS driver for data transmission. The integral (INL) and differential (DNL) nonlinearities are measured below 0.5 LSB and 0.8 LSB, respectively, for the best channel operating at a sampling frequency of 10 MS/s. The area occupies 40 μm 70 μm for one ADC channel. The power consumption is estimated as 4 μW at 1 MS/s and 38 μW at 10 MS/s with a supply rail of 1.2 V. Th...

  12. The use of DWI to assess spleen and liver quantitative ADC changes in the detection of liver fibrosis stages in chronic viral hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Cece, Hasan, E-mail: hasan_cece@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Ercan, Abdulbasit, E-mail: abdulbasitercan@hotmail.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Yıldız, Sema, E-mail: drsemayildiz@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Karakas, Ekrem, E-mail: karakasekrem@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Karakas, Omer, E-mail: dromerkarakas@hotmail.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Boyacı, Fatıma Nurefsan, E-mail: drnurefsan@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Aydogan, Timucin, E-mail: drtaydogan@yahoo.com.tr [Harran University, Faculty of Medicine, Department of Gastroenterology, Sanliurfa (Turkey); Karakas, Emel Yigit, E-mail: e.ygtkarakas@yahoo.com.tr [Sanliurfa Training and Research Hospital, Department of İnternal Medicine, Sanliurfa (Turkey); Cullu, Nesat, E-mail: nesatcullu77@gmail.com [Muğla Sıtkı Koçman University, Faculty of Medicine, Department of Radiology, Mugla (Turkey); Ulas, Turgay, E-mail: turgayulas@yahoo.com [Harran University, Faculty of Medicine, Department of İnternal Medicine, Sanliurfa (Turkey)

    2013-08-15

    This study aimed to evaluate the changes in spleen and liver diffusion-weighted magnetic resonance imaging (DWI) in chronic viral hepatitis patients. The study comprised 47 patients and 30 healthy volunteers. DWIs were obtained. Apparent Diffusion Coefficient (ADC) measurements were made by transferring the images to the workstation. The measurements of value b 1000 were made from a total of five points of the liver and three points of the spleen. Liver biopsy was performed on the 47 patients. The fibrosis stages of the patients were defined according to the METAVIR scoring system. Student's t-test was used in the comparison of mean ages, liver and spleen ADC values between the patient and the control group. Kruskal–Wallis followed by Mann–Whitney U Test with Bonferroni adjustment was performed in the comparison of mean ADC values of the patients at different stages and the control group. A statistically significant difference was determined between the patient and control group in respect of liver and spleen mean ADC values (P < 0.05). F3 group showed a significant difference compared to control and F1 and F4 group showed a significant difference compared to control, F1, F2 and F3 group in terms of the mean liver ADC value (P < 0.01). F3 and F4 group showed a significant difference compared to control and F1 group in terms of the mean spleen ADC value (P < 0.01). As a result we believe that the measurement of liver and spleen ADC values may be an indicator in the determination of the level of fibrosis.

  13. Diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient (ADC) determination in normal and pathological fetal kidneys.

    Science.gov (United States)

    Chaumoitre, K; Colavolpe, N; Shojai, R; Sarran, A; D' Ercole, C; Panuel, M

    2007-01-01

    To assess the use of diffusion-weighted magnetic resonance imaging (DW-MRI) in the evaluation of the fetal kidney and to estimate age-dependent changes in the apparent diffusion coefficient (ADC) of normal and pathological fetal kidneys. DW-MRI was performed on a 1.5-T machine at 23-38 gestational weeks in 51 pregnant women in whom the fetal kidneys were normal and in 10 whose fetuses had renal pathology (three with suspected nephropathy, three with renal tract dilatation, one with unilateral renal venous thrombosis, and three with twin-twin transfusion syndrome (TTTS)). The ADC was measured in an approximately 1-cm2 region of interest within the renal parenchyma. ADC values in normal renal parenchyma ranged from 1.1 to 1.8 10(-3) mm2 s-1. There was no significant age-dependent change in the ADC of normal kidneys. In cases of nephropathy, the ADC value was not always pathological but an ADC map could show abnormal findings. In cases of dilatation, the ADC value was difficult to determine when the dilatation was huge. In cases of TTTS, the ADC of the donor twin was higher than that of the recipient twin and the difference seemed to be related to the severity of the syndrome. Evaluation of the ADC for fetal kidneys is feasible. Fetal measurement of the ADC value and ADC maps may be useful tools with which to explore the fetal kidney when used in conjunction with current methods. DW-MR images, ADC value and ADC map seem to be useful in cases of suspected nephropathy (hyperechoic kidneys), dilated kidney and vascular pathology (renal venous thrombosis, TTTS). Copyright (c) 2006 ISUOG.

  14. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy.

    Science.gov (United States)

    Lahrsow, Maximilian; Albrecht, Moritz H; Bickford, Matthew W; Vogl, Thomas J

    2017-06-01

    To use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment. Fifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions. One month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10 -3  mm 2 /s) and no response (median 1.30 × 10 -3  mm 2 /s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC. In patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  15. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    International Nuclear Information System (INIS)

    Giannotti, E.; Waugh, S.; Priba, L.; Davis, Z.; Crowe, E.; Vinnicombe, S.

    2015-01-01

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC S ) and the ADC value of a small region of interest (ROI) on the same slice (ADC min ). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10 −3 mm 2 /s; mean ADC = 1.089 × 10 −3 mm 2 /s). The measured scan-scan CoR in the volunteers was 0.122 × 10 −3 mm 2 /s, contributing an error of 8% to the mean measured values (ADC scan1 = 1.529 × 10 −3 mm 2 /s; ADC scan

  16. Discrimination between intact and decayed pulp regions in carious teeth by ADC mapping.

    Science.gov (United States)

    Cankar, Ksenija; Nemeth, Lidija; Bajd, Franci; Vidmar, Jernej; Serša, Igor

    2014-01-01

    The aim of this study was to evaluate an advanced magnetic resonance imaging (MRI) method, apparent diffusion coefficient (ADC) mapping, in the functional assessment of carious teeth. 38 extracted human teeth with scores of 0, 3 and 6 according to International Caries Detection and Assessment System (ICDAS) criteria were screened and subsequently analyzed by MRI at 2.35 T. Histology sectioning of teeth was used for the gold standard by analyzing two extreme cases (intact and severely decayed). ADC maps of the same teeth were calculated from corresponding diffusion-weighted images and used to obtain ADC distributions along dental pulp as functions of the relative pulp length measured from the occlusal pulp side. The measured distributions were analyzed for the best fit by a four-parameter three-segment linear regression model for ADC distribution along the pulp. MRI results were in good agreement with findings in histological sections of identical teeth. The best fit model parameters, relative decayed region depth, relative transition region width and ADC values of intact and decayed pulp tissue, showed statistically significant differences between the ADC values of intact and decayed pulp tissue (1.0 × 10(-9) m(2)/s vs. 0.74-0.89 × 10(-9) m(2)/s) and the relative decayed region depth progressing with ICDAS score (3 vs. 46% with ICDAS 3 vs. ICDAS 6). The results of this feasibility study confirmed relevance of ADC mapping for the discrimination and localization of intact and decayed regions in dental pulps of carious teeth. © 2014 S. Karger AG, Basel.

  17. Regional ADC values of the normal brain: differences due to age, gender, and laterality

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 466-8550 (Japan); Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo [Department of Radiology, First Kamiida General Hospital (Japan)

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean{+-}standard deviation 2.3{+-}1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference. (orig.)

  18. Regional ADC values of the normal brain: differences due to age, gender, and laterality

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Ishigaki, Takeo; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean±standard deviation 2.3±1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference. (orig.)

  19. Diffusion-weighted MRI in prostatic lesions: Diagnostic performance of normalized ADC using normal peripheral prostatic zone as a reference

    Directory of Open Access Journals (Sweden)

    Tamer F. Taha Ali

    2018-03-01

    Full Text Available Aim of study: Evaluate the potential value of the normal peripheral zone as a reference organ to normalize prostatic lesion apparent diffusion coefficient (ADC to improve its evaluation of prostatic lesions. Patients and methods: This prospective study included 38 patients with clinical suspicion of cancer prostate (increased PSA levels (>4 ng/ml, hard prostate in digital rectal examination and who are scheduled to undergo a TRUS-guided biopsy. Conventional and DW-MRI was done and ADC was calculated. The normalized ADC value was calculated by dividing the ADC of lesion by ADC of reference site (healthy peripheral zone. DWI-MRI results were compared to the results of biopsy. Comparison of ADCs and nADCs of benign and malignant lesions was done. Receiver operating characteristics (ROC curve analysis was done. Results: The patients were classified by histopathology into non-malignant group (16 patients and malignant group (22 patients. Significant negative correlation between ADC and normalized ADC (nADC and malignancy was detected. There was no significant difference between the mean ADC of peripheral health prostatic zones (PZ between benign and malignant cases (2.221 ± 0.356 versus 1.99 ± 0.538x10−3 mm2/sec, p = 0.144.There was significant difference between the mean ADC and mean nADC in benign and malignant lesions (1.049 ± 0.217 versus 0.659 ± 0.221x10−3 mm2/sec, p < 0.001 and (0.475 ± 0.055 versus 0.328 ± 0.044, p < 0.001 respectively.There was significant higher diagnostic performance of nADC than ADC with ADC Cut-off value 0.75 × 10−3 mm2/sec and nADC cut-off value 0.39 could significantly differentiate between benign and malignant lesion with sensitivity, specificity, PPV,NPV of 86.36,75,82.61 and 80% respectively, p < 0.0001 for ADC and 95.45, 93.75, 95.45 and 93.75%, p < 0.0001 for nADC. Conclusion: diagnostic performance of nADC using normal peripheral zone is higher than

  20. Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values

    International Nuclear Information System (INIS)

    Thoermer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Kahn, Thomas; Busse, Harald; Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe; Horn, Lars-Christian

    2012-01-01

    To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm 2 ) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS = 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. (orig.)

  1. Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values

    Energy Technology Data Exchange (ETDEWEB)

    Thoermer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Kahn, Thomas; Busse, Harald [Leipzig University Hospital, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe [Leipzig University Hospital, Department of Urology, Leipzig (Germany); Horn, Lars-Christian [University of Leipzig, Institute of Pathology, Leipzig (Germany)

    2012-08-15

    To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm{sup 2}) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS = 1.6 {+-} 0.3) and second best (1.1 {+-} 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score {<=} 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 {+-} 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's {rho} -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. (orig.)

  2. Whole-tumor apparent diffusion coefficient (ADC) histogram analysis to differentiate benign peripheral neurogenic tumors from soft tissue sarcomas.

    Science.gov (United States)

    Nakajo, Masanori; Fukukura, Yoshihiko; Hakamada, Hiroto; Yoneyama, Tomohide; Kamimura, Kiyohisa; Nagano, Satoshi; Nakajo, Masayuki; Yoshiura, Takashi

    2018-02-22

    Apparent diffusion coefficient (ADC) histogram analyses have been used to differentiate tumor grades and predict therapeutic responses in various anatomic sites with moderate success. To determine the ability of diffusion-weighted imaging (DWI) with a whole-tumor ADC histogram analysis to differentiate benign peripheral neurogenic tumors (BPNTs) from soft tissue sarcomas (STSs). Retrospective study, single institution. In all, 25 BPNTs and 31 STSs. Two-b value DWI (b-values = 0, 1000s/mm 2 ) was at 3.0T. The histogram parameters of whole-tumor for ADC were calculated by two radiologists and compared between BPNTs and STSs. Nonparametric tests were performed for comparisons between BPNTs and STSs. P histogram parameters except kurtosis and entropy differed significantly between BPNTs and STSs. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  3. A mixed signal ECG processing platform with an adaptive sampling ADC for portable monitoring applications.

    Science.gov (United States)

    Kim, Hyejung; Van Hoof, Chris; Yazicioglu, Refet Firat

    2011-01-01

    This paper describes a mixed-signal ECG processing platform with an 12-bit ADC architecture that can adapt its sampling rate according to the input signals rate of change. This enables the sampling of ECG signals with significantly reduced data rate without loss of information. The presented adaptive sampling scheme reduces the ADC power consumption, enables the processing of ECG signals with lower power consumption, and reduces the power consumption of the radio while streaming the ECG signals. The test results show that running a CWT-based R peak detection algorithm using the adaptively sampled ECG signals consumes only 45.6 μW and it leads to 36% less overall system power consumption.

  4. Multi-parameter CAMAC compatible ADC scanner

    Energy Technology Data Exchange (ETDEWEB)

    Midttun, G J; Ingebretsen, F [Oslo Univ. (Norway). Fysisk Inst.; Johnsen, P J [Norsk Data A.S., Box 163, Oekern, Oslo 5, Norway

    1979-02-15

    A fast ADC scanner for multi-parameter nuclear physics experiments is described. The scanner is based on a standard CAMAC crate, and data from several different experiments can be handled simultaneously through a direct memory access (DMA) channel. The implementation on a PDP-7 computer is outlined.

  5. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giannotti, E., E-mail: ytteb84@hotmail.com [Breast Imaging Department, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Waugh, S., E-mail: shelley.waugh@nhs.net [Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Department of Clinical Radiology, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Priba, L., E-mail: lpriba@nhs.net [Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Davis, Z., E-mail: zoedavis@doctors.org.uk [Breast Imaging Department, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Crowe, E., E-mail: e.crowe@nhs.net [Department of Clinical Radiology, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Vinnicombe, S., E-mail: s.vinnicombe@dundee.ac.uk [Division of Imaging and Technology, Ninewells Hospital and Medical School, University of Dundee, Dundee DD1 9SY (United Kingdom)

    2015-09-15

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC{sub S}) and the ADC value of a small region of interest (ROI) on the same slice (ADC{sub min}). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10{sup −3} mm{sup 2}/s; mean ADC = 1.089 × 10{sup −3} mm{sup 2}/s). The measured scan-scan CoR in the volunteers was 0.122 × 10{sup −3} mm{sup 2}/s, contributing an error of 8% to the mean measured values (ADC

  6. Design of a low power 10 bit 300 ksps multi-channel SAR ADC for wireless sensor network applications

    International Nuclear Information System (INIS)

    Hong Hui; Li Shiliang; Zhou Tao

    2015-01-01

    This paper presents a low power 10 bit 300 ksps successive approximation register analog-to-digital converter (SAR ADC) which is applied in wireless sensor network (WSN) applications. A single ended energy-saving split capacitor DAC array and a latch comparator with a rail to rail input stage are utilized to implement the ADC, which can reduce power dissipation while expanding the full scale input range and improve the signal-to-noise ratio (SNR). For power optimization the supply voltage of the SAR ADC is designed to be as low as 2 V. Four analog input channels are designed which make the ADC more suitable for WSN applications. The prototype circuit is fabricated using 3.3 V, 0.35 μm 2P4M CMOS technology and occupies an active chip area of 1.23 mm 2 . The test results show that the power dissipation is only 200 μW at a 2 V power supply and a sampling rate of 166 ksps. The calculated SNR is 58.25 dB, the ENOB is 9.38 bit and the FOM is 4.95 pJ/conversion-step. (paper)

  7. Power and area efficient 4-bit column-level ADC in a CMOS pixel sensor for the ILD vertex detector

    International Nuclear Information System (INIS)

    Zhang, L; Morel, F; Hu-Guo, Ch; Hu, Y

    2013-01-01

    A 48 × 64 pixels prototype CMOS pixel sensor (CPS) integrated with 4-bit column-level, self triggered ADCs for the outer layers of the ILD vertex detector (VTX) was developed and fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. The pixel concept combines in-pixel amplification with a correlated double sampling (CDS) operation. The ADCs accommodating the pixel read out in a rolling shutter mode complete the conversion by performing a multi-bit/step approximation. The design was optimised for power saving at sampling frequency. The prototype sensor is currently at the stage of being started testing and evaluation. So what is described is based on post simulation results rather than test data. This 4-bit ADC dissipates, at a 3-V supply and 6.25-MS/s sampling rate, 486 μW in its inactive mode, which is by far the most frequent. This value rises to 714 μW in case of the active mode. Its footprint amounts to 35 × 545 μm 2 .

  8. ADC texture—An imaging biomarker for high-grade glioma?

    Energy Technology Data Exchange (ETDEWEB)

    Brynolfsson, Patrik; Hauksson, Jón; Karlsson, Mikael; Garpebring, Anders; Nyholm, Tufve, E-mail: tufve.nyholm@radfys.umu.se [Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå SE-901 87 (Sweden); Nilsson, David; Trygg, Johan [Computational Life Science Cluster (CLiC), Department of Chemistry, Umeå University, Umeå SE-901 87 (Sweden); Henriksson, Roger [Department of Radiation Sciences, Oncology, Umeå University, Umeå SE-901 87, Sweden and Regionalt Cancercentrum Stockholm, Karolinska Universitetssjukhuset, Solna, Stockholm SE-102 39 (Sweden); Birgander, Richard [Department of Radiation Sciences, Diagnostic Radiology, Umeå University, Umeå SE-901 87 (Sweden); Asklund, Thomas [Department of Radiation Sciences, Oncology, Umeå University, Umeå SE-901 87 (Sweden)

    2014-10-15

    Purpose: Survival for high-grade gliomas is poor, at least partly explained by intratumoral heterogeneity contributing to treatment resistance. Radiological evaluation of treatment response is in most cases limited to assessment of tumor size months after the initiation of therapy. Diffusion-weighted magnetic resonance imaging (MRI) and its estimate of the apparent diffusion coefficient (ADC) has been widely investigated, as it reflects tumor cellularity and proliferation. The aim of this study was to investigate texture analysis of ADC images in conjunction with multivariate image analysis as a means for identification of pretreatment imaging biomarkers. Methods: Twenty-three consecutive high-grade glioma patients were treated with radiotherapy (2 Gy/60 Gy) with concomitant and adjuvant temozolomide. ADC maps and T1-weighted anatomical images with and without contrast enhancement were collected prior to treatment, and (residual) tumor contrast enhancement was delineated. A gray-level co-occurrence matrix analysis was performed on the ADC maps in a cuboid encapsulating the tumor in coronal, sagittal, and transversal planes, giving a total of 60 textural descriptors for each tumor. In addition, similar examinations and analyses were performed at day 1, week 2, and week 6 into treatment. Principal component analysis (PCA) was applied to reduce dimensionality of the data, and the five largest components (scores) were used in subsequent analyses. MRI assessment three months after completion of radiochemotherapy was used for classifying tumor progression or regression. Results: The score scatter plots revealed that the first, third, and fifth components of the pretreatment examinations exhibited a pattern that strongly correlated to survival. Two groups could be identified: one with a median survival after diagnosis of 1099 days and one with 345 days, p = 0.0001. Conclusions: By combining PCA and texture analysis, ADC texture characteristics were identified, which seems

  9. Differentiation of benign and malignant lymph nodes with ADC value on diffusion MR: a Meta-analysis

    International Nuclear Information System (INIS)

    Long Miaomiao; Liu Lihua; Gao Guangfeng; Chen Lihua; Shen Wen; Qi Ji

    2012-01-01

    Objective: To summarize the diagnostic efficacy of ADC value for differentiation of benign and malignant lymph nodes on diffusion MRI with Meta-analysis. Methods: Published papers on differentiation of benign and malignant lymph nodes with ADC value were searched and reviewed. Quality evaluation was performed for the eligible papers before data extraction.Test for heterogeneity was performed first, then appropriate model was selected to calculate the weighted mean difference, sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio,pretest and posttest probability. The potential of ADC value for differentiation of benign and malignant lymph nodes was assessed qualitatively and quantitatively. Results: Fifteen papers including 735 cases and 1963 lymph nodes were selected. According to Meta-regression analysis, subgroup analysis and robust analysis, two studies with benign lymph nodes in patients with benign lesion and one study using chemical shift saturation technique were excluded because of their impact on the robustness of the pooled results. The weighted mean difference (WMD) between malignant and benign lymph nodes was -0.355 × 10 -3 mm 2 /s [95% confidence interval (CI):-0.423 ×10-3- -0.288 × 10 -3 mm 2 /s]. Although the cutoff of ADC value for differentiation in each study was different, the diagnostic efficacy was stable, the pooled sensitivity,specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under summarized receiver operator's curve were 0.87 (95% CI: 0.79-0.92), 0.87 (95% CI: 0.82-0.90), 6.5 (95% CI: 4.7-9.2), 0.15 (95% CI: 0.09-0.25), 43 (95% CI: 21-87), 0.93 (95% CI: 0.90-0.95). The posttest malignancy probability of benign lymph node indicated by ADC was 6%, while that of malignant lymph node was 72%. Conclusion: The ADC value can be used to differentiate benign and malignant lymph nodes with good sensitivity and specificity noninvasively. (authors)

  10. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy

    International Nuclear Information System (INIS)

    Lahrsow, Maximilian; Albrecht, Moritz H.; Bickford, Matthew W.; Vogl, Thomas J.

    2017-01-01

    PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10 −3  mm 2 /s) and no response (median 1.30 × 10 −3  mm 2 /s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  11. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lahrsow, Maximilian, E-mail: mlahrsow@gmail.com; Albrecht, Moritz H. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology (Germany); Bickford, Matthew W. [Medical University of South Carolina, Department of Radiology and Radiological Science (United States); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10{sup −3} mm{sup 2}/s) and no response (median 1.30 × 10{sup −3} mm{sup 2}/s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  12. Apparent Diffusion Coefficient (ADC) value: a potential imaging biomarker that reflects the biological features of rectal cancer.

    Science.gov (United States)

    Sun, Yiqun; Tong, Tong; Cai, Sanjun; Bi, Rui; Xin, Chao; Gu, Yajia

    2014-01-01

    We elected to analyze the correlation between the pre-treatment apparent diffusion coefficient (ADC) and the clinical, histological, and immunohistochemical status of rectal cancers. Forty-nine rectal cancer patients who received surgical resection without neoadjuvant therapy were selected that underwent primary MRI and diffusion-weighted imaging (DWI). Tumor ADC values were determined and analyzed to identify any correlations between these values and pre-treatment CEA or CA19-9 levels, and/or the histological and immunohistochemical properties of the tumor. Inter-observer agreement of confidence levels from two separate observers was suitable for ADC measurement (k  =  0.775). The pre-treatment ADC values of different T stage tumors were not equal (p  =  0.003). The overall trend was that higher T stage values correlated with lower ADC values. ADC values were also significantly lower for the following conditions: tumors with the presence of extranodal tumor deposits (p  =  0.006) and tumors with CA19-9 levels ≥ 35 g/ml (p  =  0.006). There was a negative correlation between Ki-67 LI and the ADC value (r  =  -0.318, p  =  0.026) and between the AgNOR count and the ADC value (r  =  -0.310, p  =  0.030). Significant correlations were found between the pre-treatment ADC values and T stage, extranodal tumor deposits, CA19-9 levels, Ki-67 LI, and AgNOR counts in our study. Lower ADC values were associated with more aggressive tumor behavior. Therefore, the ADC value may represent a useful biomarker for assessing the biological features and possible relationship to the status of identified rectal cancers.

  13. A high speed, selective multi-ADC to computer data transfer interface, for nuclear physics experiments

    International Nuclear Information System (INIS)

    Arctaedius, T.; Ekstroem, R.E.

    1986-08-01

    A link connecting up to fifteen Analog to Digital Converters with a computer, through a Direct Memory Access interface, is described. The interface decides which of the connected ADC:s that participate in an event, and transfers the output-data from these to the computer, accompanied with a 2-byte word identifying the participating ADC:s. This data format can be recorded on tape without further transformations, and is easy to unfold at the off-line analysis. Data transfer is accomplished in less than a few microseconds, which is made possible by the use of high speed TTL circuits. (authors)

  14. Fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, W; Franz, N; Ziegler, G [Technische Univ. Muenchen, Garching (Germany, F.R.). Fakultaet Physik; Hegewisch, S; Kunz, D; Maier, D; Lutter, R; Schoeffel, K; Stanzel, B [Muenchen Univ. (Germany, F.R.). Sektion Physik; Drescher, B [Hahn-Meitner-Institut fuer Kernforschung Berlin G.m.b.H. (Germany, F.R.)

    1982-03-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed.

  15. An 11-bit 200 MS/s subrange SAR ADC with low-cost integrated reference buffer

    Science.gov (United States)

    He, Xiuju; Gu, Xian; Li, Weitao; Jiang, Hanjun; Li, Fule; Wang, Zhihua

    2017-10-01

    This paper presents an 11-bit 200 MS/s subrange SAR ADC with an integrated reference buffer in 65 nm CMOS. The proposed ADC employs a 3.5-bit flash ADC for coarse conversion, and a compact timing scheme at the flash/SAR boundary to speed up the conversion. The flash decision is used to control charge compensating for the reference voltage to reduce its input-dependent fluctuation. Measurement results show that the fabricated ADC has achieved significant improvement by applying the reference charge compensation. In addition, the ADC achieves a maximum signal-to-noise-and-distortion ratio of 59.3 dB at 200 MS/s. It consumes 3.91 mW from a 1.2 V supply, including the reference buffer. Project supported by the Zhongxing Telecommunication Equipment Corporation and Beijing Microelectronics Technology Institute.

  16. Apparent Diffusion Coefficient (ADC value: a potential imaging biomarker that reflects the biological features of rectal cancer.

    Directory of Open Access Journals (Sweden)

    Yiqun Sun

    Full Text Available OBJECTIVE: We elected to analyze the correlation between the pre-treatment apparent diffusion coefficient (ADC and the clinical, histological, and immunohistochemical status of rectal cancers. MATERIALS AND METHODS: Forty-nine rectal cancer patients who received surgical resection without neoadjuvant therapy were selected that underwent primary MRI and diffusion-weighted imaging (DWI. Tumor ADC values were determined and analyzed to identify any correlations between these values and pre-treatment CEA or CA19-9 levels, and/or the histological and immunohistochemical properties of the tumor. RESULTS: Inter-observer agreement of confidence levels from two separate observers was suitable for ADC measurement (k  =  0.775. The pre-treatment ADC values of different T stage tumors were not equal (p  =  0.003. The overall trend was that higher T stage values correlated with lower ADC values. ADC values were also significantly lower for the following conditions: tumors with the presence of extranodal tumor deposits (p  =  0.006 and tumors with CA19-9 levels ≥ 35 g/ml (p  =  0.006. There was a negative correlation between Ki-67 LI and the ADC value (r  =  -0.318, p  =  0.026 and between the AgNOR count and the ADC value (r  =  -0.310, p  =  0.030. CONCLUSION: Significant correlations were found between the pre-treatment ADC values and T stage, extranodal tumor deposits, CA19-9 levels, Ki-67 LI, and AgNOR counts in our study. Lower ADC values were associated with more aggressive tumor behavior. Therefore, the ADC value may represent a useful biomarker for assessing the biological features and possible relationship to the status of identified rectal cancers.

  17. A continuous-time/discrete-time mixed audio-band sigma delta ADC

    International Nuclear Information System (INIS)

    Liu Yan; Hua Siliang; Wang Donghui; Hou Chaohuan

    2011-01-01

    This paper introduces a mixed continuous-time/discrete-time, single-loop, fourth-order, 4-bit audio-band sigma delta ADC that combines the benefits of continuous-time and discrete-time circuits, while mitigating the challenges associated with continuous-time design. Measurement results show that the peak SNR of this ADC reaches 100 dB and the total power consumption is less than 30 mW. (semiconductor integrated circuits)

  18. Diffusion-weighted imaging of breast lesions: Region-of-interest placement and different ADC parameters influence apparent diffusion coefficient values

    Energy Technology Data Exchange (ETDEWEB)

    Bickel, Hubert; Pinker, Katja; Polanec, Stephan; Magometschnigg, Heinrich; Wengert, Georg; Spick, Claudio; Helbich, Thomas H.; Baltzer, Pascal [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bogner, Wolfgang [Medical University Vienna - MR Center of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bago-Horvath, Zsuzsanna [Medical University Vienna, Department of Pathology, Vienna (Austria)

    2017-05-15

    To investigate the influence of region-of-interest (ROI) placement and different apparent diffusion coefficient (ADC) parameters on ADC values, diagnostic performance, reproducibility and measurement time in breast tumours. In this IRB-approved, retrospective study, 149 histopathologically proven breast tumours (109 malignant, 40 benign) in 147 women (mean age 53.2) were investigated. Three radiologists independently measured minimum, mean and maximum ADC, each using three ROI placement approaches:1 - small 2D-ROI, 2 - large 2D-ROI and 3 - 3D-ROI covering the whole lesion. One reader performed all measurements twice. Median ADC values, diagnostic performance, reproducibility, and measurement time were calculated and compared between all combinations of ROI placement approaches and ADC parameters. Median ADC values differed significantly between the ROI placement approaches (p <.001). Minimum ADC showed the best diagnostic performance (AUC.928-.956), followed by mean ADC obtained from 2D ROIs (.926-.94). Minimum and mean ADC showed high intra- (ICC.85-.94) and inter-reader reproducibility (ICC.74-.94). Median measurement time was significantly shorter for the 2D ROIs (p <.001). ROI placement significantly influences ADC values measured in breast tumours. Minimum and mean ADC acquired from 2D-ROIs are useful for the differentiation of benign and malignant breast lesions, and are highly reproducible, with rapid measurement. (orig.)

  19. A 10 MS/s 8-bit charge-redistribution ADC for hybrid pixel applications in 65 m CMOS

    International Nuclear Information System (INIS)

    Kishishita, Tetsuichi; Hemperek, Tomasz; Krüger, Hans; Koch, Manuel; Germic, Leonard; Wermes, Norbert

    2013-01-01

    The design and measurement results of an 8-bit SAR ADC, based on a charge-redistribution DAC, are presented. This ADC is characterized by superior power efficiency and small area, realized by employing a lateral metal–metal capacitor array and a dynamic two-stage comparator. To avoid the need for a high-speed clock and its associated power consumption, an asynchronous logic was implemented in a logic control cell. A test chip has been developed in a 65 nm CMOS technology, including eight ADC channels with different layout flavors of the capacitor array, a transimpedance amplifier as a signal input structure, a serializer, and a custom-made LVDS driver for data transmission. The integral (INL) and differential (DNL) nonlinearities are measured below 0.5 LSB and 0.8 LSB, respectively, for the best channel operating at a sampling frequency of 10 MS/s. The area occupies 40μm×70μm for one ADC channel. The power consumption is estimated as 4μW at 1 MS/s and 38μW at 10 MS/s with a supply rail of 1.2 V. These excellent performance features and the natural radiation hardness of the design, due to the thin gate oxide thickness of transistors, are very interesting for front-end electronics ICs of future hybrid-pixel detector systems

  20. A 10 MS/s 8-bit charge-redistribution ADC for hybrid pixel applications in 65 m CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Kishishita, Tetsuichi, E-mail: kisisita@physik.uni-bonn.de; Hemperek, Tomasz; Krüger, Hans; Koch, Manuel; Germic, Leonard; Wermes, Norbert

    2013-12-21

    The design and measurement results of an 8-bit SAR ADC, based on a charge-redistribution DAC, are presented. This ADC is characterized by superior power efficiency and small area, realized by employing a lateral metal–metal capacitor array and a dynamic two-stage comparator. To avoid the need for a high-speed clock and its associated power consumption, an asynchronous logic was implemented in a logic control cell. A test chip has been developed in a 65 nm CMOS technology, including eight ADC channels with different layout flavors of the capacitor array, a transimpedance amplifier as a signal input structure, a serializer, and a custom-made LVDS driver for data transmission. The integral (INL) and differential (DNL) nonlinearities are measured below 0.5 LSB and 0.8 LSB, respectively, for the best channel operating at a sampling frequency of 10 MS/s. The area occupies 40μm×70μm for one ADC channel. The power consumption is estimated as 4μW at 1 MS/s and 38μW at 10 MS/s with a supply rail of 1.2 V. These excellent performance features and the natural radiation hardness of the design, due to the thin gate oxide thickness of transistors, are very interesting for front-end electronics ICs of future hybrid-pixel detector systems.

  1. Automatic Single Event Effects Sensitivity Analysis of a 13-Bit Successive Approximation ADC

    Science.gov (United States)

    Márquez, F.; Muñoz, F.; Palomo, F. R.; Sanz, L.; López-Morillo, E.; Aguirre, M. A.; Jiménez, A.

    2015-08-01

    This paper presents Analog Fault Tolerant University of Seville Debugging System (AFTU), a tool to evaluate the Single-Event Effect (SEE) sensitivity of analog/mixed signal microelectronic circuits at transistor level. As analog cells can behave in an unpredictable way when critical areas interact with the particle hitting, there is a need for designers to have a software tool that allows an automatic and exhaustive analysis of Single-Event Effects influence. AFTU takes the test-bench SPECTRE design, emulates radiation conditions and automatically evaluates vulnerabilities using user-defined heuristics. To illustrate the utility of the tool, the SEE sensitivity of a 13-bits Successive Approximation Analog-to-Digital Converter (ADC) has been analysed. This circuit was selected not only because it was designed for space applications, but also due to the fact that a manual SEE sensitivity analysis would be too time-consuming. After a user-defined test campaign, it was detected that some voltage transients were propagated to a node where a parasitic diode was activated, affecting the offset cancelation, and therefore the whole resolution of the ADC. A simple modification of the scheme solved the problem, as it was verified with another automatic SEE sensitivity analysis.

  2. A custom floating point format ADC for LHC calorimetry

    International Nuclear Information System (INIS)

    Hermel, V.; Lecoq, J.; Bohner, G.

    1996-01-01

    Due to their large dynamic range (in excess of 16 bits) signals from LHC calorimetry poses severe problems to the shaping and digitizing circuits. We are investigating a solution for an ADC based on a custom floating point format. Since the calorimeter precision is limited, the full dynamic range can be split into 8 positive sub-ranges and 5 negative ones, each with an 8 bits dynamic. The reduced number of bits (8 for the mantissa, 4 for the exponent and 1 for the sign) translates itself into a reduction of the power consumption both of the ADC and of the following digital filtering stages. (authors)

  3. Differentiation of orbital lymphoma and idiopathic orbital inflammatory pseudotumor: combined diagnostic value of conventional MRI and histogram analysis of ADC maps.

    Science.gov (United States)

    Ren, Jiliang; Yuan, Ying; Wu, Yingwei; Tao, Xiaofeng

    2018-05-02

    The overlap of morphological feature and mean ADC value restricted clinical application of MRI in the differential diagnosis of orbital lymphoma and idiopathic orbital inflammatory pseudotumor (IOIP). In this paper, we aimed to retrospectively evaluate the combined diagnostic value of conventional magnetic resonance imaging (MRI) and whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in the differentiation of the two lesions. In total, 18 patients with orbital lymphoma and 22 patients with IOIP were included, who underwent both conventional MRI and diffusion weighted imaging before treatment. Conventional MRI features and histogram parameters derived from ADC maps, including mean ADC (ADC mean ), median ADC (ADC median ), skewness, kurtosis, 10th, 25th, 75th and 90th percentiles of ADC (ADC 10 , ADC 25 , ADC 75 , ADC 90 ) were evaluated and compared between orbital lymphoma and IOIP. Multivariate logistic regression analysis was used to identify the most valuable variables for discriminating. Differential model was built upon the selected variables and receiver operating characteristic (ROC) analysis was also performed to determine the differential ability of the model. Multivariate logistic regression showed ADC 10 (P = 0.023) and involvement of orbit preseptal space (P = 0.029) were the most promising indexes in the discrimination of orbital lymphoma and IOIP. The logistic model defined by ADC 10 and involvement of orbit preseptal space was built, which achieved an AUC of 0.939, with sensitivity of 77.30% and specificity of 94.40%. Conventional MRI feature of involvement of orbit preseptal space and ADC histogram parameter of ADC 10 are valuable in differential diagnosis of orbital lymphoma and IOIP.

  4. A FASTBUS flash ADC system for the Mark II vertex chamber

    International Nuclear Information System (INIS)

    Barker, L.

    1988-10-01

    This is a description of a flash ADC system built for the Mark II experiment at the Stanford Linear Accelerator Center (SLAC). This system was designed for use in the experiment's vertex chamber where signals could occur over a relatively long time, approximately 10 microseconds. This long time, coupled with fast cable amplifiers, necessitated an alternate design approach than was used with a dE/dX FASTBUS flash ADC design. 1 ref., 6 figs

  5. Apparent diffusion coefficient (ADC) does not correlate with different serological parameters in myositis and myopathy.

    Science.gov (United States)

    Meyer, Hans-Jonas; Ziemann, Oliver; Kornhuber, Malte; Emmer, Alexander; Quäschling, Ulf; Schob, Stefan; Surov, Alexey

    2018-06-01

    Background Magnetic resonance imaging (MRI) is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an imaging modality, which can reflect microstructural tissue composition. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules in tissue. Purpose To investigate ADC values in patients with myositis and non-inflammatory myopathy and to analyze possible associations between ADC and laboratory parameters in these patients. Material and Methods Overall, 17 patients with several myositis entities, eight patients with non-inflammatory myopathies, and nine patients without muscle disorder as a control group were included in the study (mean age = 55.3 ± 14.3 years). The diagnosis was confirmed by histopathology in every case. DWI was obtained in a 1.5-T scanner using two b-values: 0 and 1000 s/mm 2 . In all patients, the blood sample was acquired within three days to the MRI. The following serological parameters were estimated: C-reactive protein, lactate dehydrogenase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, and myoglobine. Results The estimated mean ADC value for the myositis group was 1.89 ± 0.37 × 10 -3  mm 2 /s and for the non-inflammatory myopathy group was 1.79 ± 0.33 × 10 -3  mm 2 /s, respectively. The mean ADC values (1.15 ± 0.37 × 10 -3  mm 2 /s) were significantly higher to unaffected muscles (vs. myositis P = 0.0002 and vs. myopathy P = 0.0021). There were no significant correlations between serological parameters and ADC values. Conclusion Affected muscles showed statistically significantly higher ADC values than normal muscles. No linear correlations between ADC and serological parameters were identified.

  6. Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Nan-Jie [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Wong, Chun-Sing, E-mail: drcswong@gmail.com [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chu, Yiu-Ching [Department of Radiology, Kwong Wah Hospital, Hong Kong (China); Guo, Hua [Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing (China); Huang, Bingsheng [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chan, Queenie [Philips Healthcare, Hong Kong (China)

    2013-10-01

    Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

  7. DW-MRI of liver lesions: Can a single ADC-value represent the entire lesion?

    International Nuclear Information System (INIS)

    Schmid-Tannwald, C.; Dahi, F.; Jiang, Y.; Ivancevic, M.K.; Rist, C.; Sethi, I.; Oommen, J.; Oto, A.

    2014-01-01

    Aim: To evaluate whether focal liver lesions (FLLs) exhibit a homogeneous appearance on apparent diffusion coefficient (ADC) maps and whether there is inter-section variation in the calculated ADC values of FLLs (inter-section range). Materials and methods: Eighty-eight patients with 128 FLLs (70 benign, 58 malignant) who underwent abdominal magnetic resonance imaging (MRI) including diffusion-weighted (DW)-MRI were included. Two observers evaluated variation of signal intensity of each FLL within each ADC map image (intra-section) and among different ADC map images through the lesion (inter-section). ADC values of each FLL and neighbouring liver parenchyma were measured on all sections. The inter-section range of FLLs was compared with the neighbouring liver parenchyma. Results: Intra-section inhomogeneity was noted in 39.8% (97/244 sections) and 38.9% (95/244) of benign lesions, and 61% (114/187 sections) and 61.5% (115/187) of malignant lesions, by observer 1 and observer 2, respectively. Inter-section inhomogeneity was noted in 25.7% (18/70) and 27.1% (19/70) of benign lesions, and 51.7% (30/58) and 50% (29/58) of malignant lesions, by observer 1 and observer 2, respectively. The inter-section range for both benign (0.28 × 10 −3  mm²/s) and malignant (0.25 × 10 −3  mm²/s) FLLs were significantly greater than that of liver parenchyma surrounding benign (0.16 × 10 −3  mm²/s, p < 0.001) and malignant (0.14 × 10 −3  mm²/s, p = 0.01) FLLs. Conclusion: Due to intra-/inter-section variations in ADC values of benign and malignant FLLs, a single ADC value may not reliably represent the entire lesion

  8. Volterra Filtering for ADC Error Correction

    Directory of Open Access Journals (Sweden)

    J. Saliga

    2001-09-01

    Full Text Available Dynamic non-linearity of analog-to-digital converters (ADCcontributes significantly to the distortion of digitized signals. Thispaper introduces a new effective method for compensation such adistortion based on application of Volterra filtering. Considering ana-priori error model of ADC allows finding an efficient inverseVolterra model for error correction. Efficiency of proposed method isdemonstrated on experimental results.

  9. A fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    International Nuclear Information System (INIS)

    Liebl, W.; Franz, N.; Ziegler, G.

    1982-01-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed. (orig.)

  10. A FASTBUS flash ADC system for the Mark II vertex chamber

    Energy Technology Data Exchange (ETDEWEB)

    Barker, L.

    1988-10-01

    This is a description of a flash ADC system built for the Mark II experiment at the Stanford Linear Accelerator Center (SLAC). This system was designed for use in the experiment's vertex chamber where signals could occur over a relatively long time, approximately 10 microseconds. This long time, coupled with fast cable amplifiers, necessitated an alternate design approach than was used with a dE/dX FASTBUS flash ADC design. 1 ref., 6 figs.

  11. HVM die yield improvement as a function of DRSEM ADC

    Science.gov (United States)

    Maheshwary, Sonu; Haas, Terry; McGarvey, Steve

    2010-03-01

    Given the current manufacturing technology roadmap and the competitiveness of the global semiconductor manufacturing environment in conjunction with the semiconductor manufacturing market dynamics, the market place continues to demand a reduced die manufacturing cost. This continuous pressure on lowering die cost in turn drives an aggressive yield learning curve, a key component of which is defect reduction of manufacturing induced anomalies. In order to meet and even exceed line and die yield targets there is a need to revamp defect classification strategies and place a greater emphasize on increasing the accuracy and purity of the Defect Review Scanning Electron Microscope (DRSEM) Automated Defect Classification (ADC) results while placing less emphasis on the ADC results of patterned/un-patterned wafer inspection systems. The increased emphasis on DRSEM ADC results allows for a high degree of automation and consistency in the classification data and eliminates variance induced by the manufacturing staff. This paper examines the use of SEM based Auto Defect Classification in a high volume manufacturing environment as a key driver in the reduction of defect limited yields.

  12. A 10-bit 120-MS/s pipelined ADC with improved switch and layout scaling strategy

    International Nuclear Information System (INIS)

    Zhou Jia; Xu Lili; Li Fule; Wang Zhihua

    2015-01-01

    A 10 bit, 120 MS/s two-channel pipelined analog-to digital converter (ADC) is presented. The ADC is featured with improved switch by using the body effect to improve its conduction performance. A scaling down strategy is proposed to get more efficiency in the OTAs layout design. Implemented in a 0.18-μm CMOS technology, the ADC's prototype occupied an area of 2.05 × 1.83 mm 2 . With a sampling rate of 120-MS/s and an input of 4.9 MHz, the ADC achieves a spurious-free-dynamic range of 74.32 dB and signal-to-noise-and-distortion ratio of 55.34 dB, while consuming 220-mW/channel at 3-V supply. (paper)

  13. Diagnostic value of diffusion weighted MRI and ADC in differential diagnosis of cavernous hemangioma of the liver.

    Science.gov (United States)

    Tokgoz, Ozlem; Unlu, Ebru; Unal, Ilker; Serifoglu, Ismail; Oz, Ilker; Aktas, Elif; Caglar, Emrah

    2016-03-01

    To investigate the use of diffusion weighted magnetic resonance imaging (DWI) and the apparent diffusion coefficient (ADC) values in the diagnosis of hemangioma. The study population consisted of 72 patients with liver masses larger than 1 cm (72 focal lesions). DWI examination with a b value of 600 s/mm2 was carried out for all patients. After DWI examination, an ADC map was created and ADC values were measured for 72 liver masses and normal liver tissue (control group). The average ADC values of normal liver tissue and focal liver lesions, the "cut-off" ADC values, and the diagnostic sensitivity and specificity of the ADC map in diagnosing hemangioma, benign and malignant lesions were researched. Of the 72 liver masses, 51 were benign and 21 were malignant. Benign lesions comprised 38 hemangiomas and 13 simple cysts. Malignant lesions comprised 9 hepatocellular carcinomas, and 12 metastases. The highest ADC values were measured for cysts (3.782±0.53×10(-3) mm(2)/s) and hemangiomas (2.705±0.63×10(-3) mm(2)/s). The average ADC value of hemangiomas was significantly higher than malignant lesions and the normal control group (p<0.001). The average ADC value of cysts were significantly higher when compared to hemangiomas and normal control group (p<0.001). To distinguish hemangiomas from malignant liver lesions, the "cut-off" ADC value of 1.800×10(-3) mm(2)/s had a sensitivity of 97.4% and a specificity of 90.9%. To distinguish hemangioma from normal liver parenchyma the "cut-off" value of 1.858×10(-3) mm(2)/s had a sensitivity of 97.4% and a specificity of 95.7%. To distinguish benign liver lesions from malignant liver lesions the "cut-off" value of 1.800×10(-3) mm(2)/s had a sensitivity of 96.1% and a specificity of 90.0%. DWI and quantitative measurement of ADC values can be used in differential diagnosis of benign and malignant liver lesions and also in the diagnosis and differentiation of hemangiomas. When dynamic examination cannot distinguish cases with

  14. 12-bit 32 channel 500 MS/s low-latency ADC for particle accelerators real-time control

    Science.gov (United States)

    Karnitski, Anton; Baranauskas, Dalius; Zelenin, Denis; Baranauskas, Gytis; Zhankevich, Alexander; Gill, Chris

    2017-09-01

    Particle beam control systems require real-time low latency digital feedback with high linearity and dynamic range. Densely packed electronic systems employ high performance multichannel digitizers causing excessive heat dissipation. Therefore, low power dissipation is another critical requirement for these digitizers. A described 12-bit 500 MS/s ADC employs a sub-ranging architecture based on a merged sample & hold circuit, a residue C-DAC and a shared 6-bit flash core ADC. The core ADC provides a sequential coarse and fine digitization featuring a latency of two clock cycles. The ADC is implemented in a 28 nm CMOS process and consumes 4 mW of power per channel from a 0.9 V supply (interfacing and peripheral circuits are excluded). Reduced power consumption and small on-chip area permits the implementation of 32 ADC channels on a 10.7 mm2 chip. The ADC includes a JESD204B standard compliant output data interface operated at the 7.5 Gbps/ch rate. To minimize the data interface related time latency, a special feature permitting to bypass the JESD204B interface is built in. DoE Phase I Award Number: DE-SC0017213.

  15. ADC common noise correction and zero suppression in the PIBETA detector

    International Nuclear Information System (INIS)

    Frlez, E.; Pocanic, D.; Ritt, S.

    2001-01-01

    We describe a simple procedure for reducing Analog-to-Digital Converter (ADC) common noise in modular detectors that does not require additional hardware. A method using detector noise groups should work well for modular particle detectors such as segmented electromagnetic calorimeters, plastic scintillator hodoscopes, cathode strip wire chambers, segmented active targets, and the like. We demonstrate a 'second pedestal noise correction' method by comparing representative ADC pedestal spectra for various elements of the PIBETA detector before and after the applied correction

  16. Volumetric segmentation of ADC maps and utility of standard deviation as measure of tumor heterogeneity in soft tissue tumors.

    Science.gov (United States)

    Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K

    2016-01-01

    Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Utility of whole-lesion ADC histogram metrics for assessing the malignant potential of pancreatic intraductal papillary mucinous neoplasms (IPMNs).

    Science.gov (United States)

    Hoffman, David H; Ream, Justin M; Hajdu, Christina H; Rosenkrantz, Andrew B

    2017-04-01

    To evaluate whole-lesion ADC histogram metrics for assessing the malignant potential of pancreatic intraductal papillary mucinous neoplasms (IPMNs), including in comparison with conventional MRI features. Eighteen branch-duct IPMNs underwent MRI with DWI prior to resection (n = 16) or FNA (n = 2). A blinded radiologist placed 3D volumes-of-interest on the entire IPMN on the ADC map, from which whole-lesion histogram metrics were generated. The reader also assessed IPMN size, mural nodularity, and adjacent main-duct dilation. Benign (low-to-intermediate grade dysplasia; n = 10) and malignant (high-grade dysplasia or invasive adenocarcinoma; n = 8) IPMNs were compared. Whole-lesion ADC histogram metrics demonstrating significant differences between benign and malignant IPMNs were: entropy (5.1 ± 0.2 vs. 5.4 ± 0.2; p = 0.01, AUC = 86%); mean of the bottom 10th percentile (2.2 ± 0.4 vs. 1.6 ± 0.7; p = 0.03; AUC = 81%); and mean of the 10-25th percentile (2.8 ± 0.4 vs. 2.3 ± 0.6; p = 0.04; AUC = 79%). The overall mean ADC, skewness, and kurtosis were not significantly different between groups (p ≥ 0.06; AUC = 50-78%). For entropy (highest performing histogram metric), an optimal threshold of >5.3 achieved a sensitivity of 100%, a specificity of 70%, and an accuracy of 83% for predicting malignancy. No significant difference (p = 0.18-0.64) was observed between benign and malignant IPMNs for cyst size ≥3 cm, adjacent main-duct dilatation, or mural nodule. At multivariable analysis of entropy in combination with all other ADC histogram and conventional MRI features, entropy was the only significant independent predictor of malignancy (p = 0.004). Although requiring larger studies, ADC entropy obtained from 3D whole-lesion histogram analysis may serve as a biomarker for identifying the malignant potential of IPMNs, independent of conventional MRI features.

  18. Auto Code Generation for Simulink-Based Attitude Determination Control System

    Science.gov (United States)

    MolinaFraticelli, Jose Carlos

    2012-01-01

    This paper details the work done to auto generate C code from a Simulink-Based Attitude Determination Control System (ADCS) to be used in target platforms. NASA Marshall Engineers have developed an ADCS Simulink simulation to be used as a component for the flight software of a satellite. This generated code can be used for carrying out Hardware in the loop testing of components for a satellite in a convenient manner with easily tunable parameters. Due to the nature of the embedded hardware components such as microcontrollers, this simulation code cannot be used directly, as it is, on the target platform and must first be converted into C code; this process is known as auto code generation. In order to generate C code from this simulation; it must be modified to follow specific standards set in place by the auto code generation process. Some of these modifications include changing certain simulation models into their atomic representations which can bring new complications into the simulation. The execution order of these models can change based on these modifications. Great care must be taken in order to maintain a working simulation that can also be used for auto code generation. After modifying the ADCS simulation for the auto code generation process, it is shown that the difference between the output data of the former and that of the latter is between acceptable bounds. Thus, it can be said that the process is a success since all the output requirements are met. Based on these results, it can be argued that this generated C code can be effectively used by any desired platform as long as it follows the specific memory requirements established in the Simulink Model.

  19. Whole lesion histogram analysis of meningiomas derived from ADC values. Correlation with several cellularity parameters, proliferation index KI 67, nucleic content, and membrane permeability.

    Science.gov (United States)

    Surov, Alexey; Hamerla, Gordian; Meyer, Hans Jonas; Winter, Karsten; Schob, Stefan; Fiedler, Eckhard

    2018-09-01

    To analyze several histopathological features and their possible correlations with whole lesion histogram analysis derived from ADC maps in meningioma. The retrospective study involved 36 patients with primary meningiomas. For every tumor, the following histogram analysis parameters of apparent diffusion coefficient (ADC) were calculated: ADC mean , ADC max , ADC min , ADC median , ADC mode , ADC percentiles: P10, P25, P75, P90, as well kurtosis, skewness, and entropy. All measures were performed by two radiologists. Proliferation index KI 67, minimal, maximal and mean cell count, total nucleic area, and expression of water channel aquaporin 4 (AQP4) were estimated. Spearman's correlation coefficient was used to analyze associations between investigated parameters. A perfect interobserver agreement for all ADC values (0.84-0.97) was identified. All ADC values correlated inversely with tumor cellularity with the strongest correlation between P10, P25 and mean cell count (-0.558). KI 67 correlated inversely with all ADC values except ADC min . ADC parameters did not correlate with total nucleic area. All ADC values correlated statistically significant with expression of AQP4. ADC histogram analysis is a valid method with an excellent interobserver agreement. Cellularity parameters and proliferation potential are associated with different ADC values. Membrane permeability may play a greater role for water diffusion than cell count and proliferation activity. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Alterations of apparent diffusion coefficient (ADC) in the brain of rats chronically exposed to lead acetate.

    Science.gov (United States)

    López-Larrubia, Pilar; Cauli, Omar

    2011-03-15

    Diffusion-weighted imaging (DWI) allows the assessment of the water apparent diffusion coefficient (ADC), a measure of tissue water diffusivity which is altered during different pathological conditions such as cerebral oedema. By means of DWI, we repeatedly measured in the same rats apparent diffusion coefficient ADC in different brain areas (motor cortex (MCx), somato-sensory cortex (SCx), caudate-putamen (CPu), hippocampus (Hip), mesencephalic reticular formation (RF), corpus callosum (CC) and cerebellum (Cb)) after 1 week, 4 and 12 weeks of lead acetate exposure via drinking water (50 or 500 ppm). After 12 weeks of lead exposure rats received albumin-Evans blue complex administration and were sacrificed 1h later. Blood-brain barrier permeability and water tissue content were determined in order to evaluate their relationship with ADC changes. Chronic exposure to lead acetate (500 ppm) for 4 weeks increased ADC values in Hip, RF and Cb but no in other brain areas. After 12 weeks of lead acetate exposure at 500 ppm ADC is significantly increased also in CPu and CC. Brain areas displaying high ADC values after lead exposure showed also an increased water content and increased BBB permeability to Evans blue-albumin complex. Exposure to 50 ppm for 12 weeks increased ADC values and BBB permeability in the RF and Cb. In summary, chronic lead exposure induces cerebral oedema in the adult brain depending on the brain area and the dose of exposure. RF and Cb appeared the most sensitive brain areas whereas cerebral cortex appears resistant to lead-induced cerebral oedema. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. A 2-GS/s 6-bit self-calibrated flash ADC

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Youtao; Chen Chen [National Key Laboratory of Monolithic Integrated Circuits and Modules, Nanjing Electronic Devices Institute, Nanjing 210016 (China); Li Xiaopeng; Zhang Min; Liu Ao, E-mail: zhangyt@nedc-ic.co [Nanjing Electronic Devices Institute, Nanjing 210016 (China)

    2010-09-15

    A single channel 2-GS/s 6-bit ADC with cascade resistive averaging and self foreground calibration is demonstrated in 0.18-{mu}m CMOS. The calibration method based on DAC trimming improves the linearity and dynamic performance further. The peak DNL and INL are measured as 0.34 and 0.22 LSB, respectively. The SNDR and SFDR have achieved 36.5 and 45.9 dB, respectively, with 1.22 MHz input signal and 2 GS/s. The proposed ADC, including on-chip track-and-hold amplifiers and clock buffers, consumes 570 mW from a single 1.8 V supply while operating at 2 GS/s. (semiconductor integrated circuits)

  2. CAMAC interface module for PACE ADC system

    Energy Technology Data Exchange (ETDEWEB)

    Dalton, C G; Mischke, R E [Los Alamos Scientific Lab., N.Mex. (USA); Scott, D T

    1977-03-15

    This report describes a CAMAC module designed to buffer and transfer data from the Tennelec multiplexed ADC system called PACE to a computer. It can be operated in either of two modes: as an eight-deep, first-in-first-out (FIFO) circular buffer, or in channel mode with a single buffer reserved for each PACE channel.

  3. The appearance of ADCs in the non-affected areas of the patients with MELAS

    International Nuclear Information System (INIS)

    Liu, Zhenghua; Liu, Xiwei; Hui, Lihong; Xie, Sheng; Xiao, Jiangxi; Jiang, Xuexiang; Zhao, Danhua; Wang, Xiaoying

    2011-01-01

    The exact mechanism of the mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) remain unclear. Diffusion-weighted imaging (DWI) is a magnetic resonance (MR) imaging technique for studying the pathophysiologic change of the MELAS. The purpose of the study is to see whether the apparent diffusion coefficient (ADC) of MELAS in the non-affected areas is different from the ADC of the normal subjects and to speculate the pathophysiological mechanisms of the MELAS. Sixteen cases of MELAS were retrospectively analyzed. Thirty healthy subjects were chosen to constitute the control group. All of them were performed on the 3.0T whole-body MR scanner with axial view T2 fluid attenuated inversion recovery (flair), T2-weighted imaging, T1flair, and DWI. An ADC map was reconstructed in the workstation. Two to five regions of interest were put in the non-affected frontal lobe and basal ganglia. All data took statistical analysis. There were significant differences between the ADC of the patients with MELAS and the controls in the non-affected areas, including the superior frontal gyrus, precentral gyrus, corpus striatum, thalamus, and white matter of the semi-oval centrum. ADCs in the non-affected areas of the patients with MELAS are higher than those of the normal subjects. Pathological changes take place in the non-affected areas of the patients with MELAS. (orig.)

  4. The appearance of ADCs in the non-affected areas of the patients with MELAS

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhenghua; Liu, Xiwei; Hui, Lihong; Xie, Sheng; Xiao, Jiangxi; Jiang, Xuexiang [Peking University First Hospital, Center for Functional Imaging, Peking University, The Department of Radiology, Beijing (China); Zhao, Danhua [Peking University First Hospital, The Department of Neurology, Beijing (China); Wang, Xiaoying [Peking University First Hospital, Center for Functional Imaging, Peking University, The Department of Radiology, Beijing (China); Peking University First Hospital, The Department of Radiology, 8, Xishiku Street, Xicheng District, Beijing (China)

    2011-04-15

    The exact mechanism of the mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) remain unclear. Diffusion-weighted imaging (DWI) is a magnetic resonance (MR) imaging technique for studying the pathophysiologic change of the MELAS. The purpose of the study is to see whether the apparent diffusion coefficient (ADC) of MELAS in the non-affected areas is different from the ADC of the normal subjects and to speculate the pathophysiological mechanisms of the MELAS. Sixteen cases of MELAS were retrospectively analyzed. Thirty healthy subjects were chosen to constitute the control group. All of them were performed on the 3.0T whole-body MR scanner with axial view T2 fluid attenuated inversion recovery (flair), T2-weighted imaging, T1flair, and DWI. An ADC map was reconstructed in the workstation. Two to five regions of interest were put in the non-affected frontal lobe and basal ganglia. All data took statistical analysis. There were significant differences between the ADC of the patients with MELAS and the controls in the non-affected areas, including the superior frontal gyrus, precentral gyrus, corpus striatum, thalamus, and white matter of the semi-oval centrum. ADCs in the non-affected areas of the patients with MELAS are higher than those of the normal subjects. Pathological changes take place in the non-affected areas of the patients with MELAS. (orig.)

  5. Achievable ADC Performance by Postcorrection Utilizing Dynamic Modeling of the Integral Nonlinearity

    Directory of Open Access Journals (Sweden)

    Peter Händel

    2008-03-01

    Full Text Available There is a need for a universal dynamic model of analog-to-digital converters (ADC’s aimed for postcorrection. However, it is complicated to fully describe the properties of an ADC by a single model. An alternative is to split up the ADC model in different components, where each component has unique properties. In this paper, a model based on three components is used, and a performance analysis for each component is presented. Each component can be postcorrected individually and by the method that best suits the application. The purpose of postcorrection of an ADC is to improve the performance. Hence, for each component, expressions for the potential improvement have been developed. The measures of performance are total harmonic distortion (THD and signal to noise and distortion (SINAD, and to some extent spurious-free dynamic range (SFDR.

  6. Increase in speed of Wilkinson-type ADC and improvement of differential non-linearity

    Energy Technology Data Exchange (ETDEWEB)

    Kinbara, S [Japan Atomic Energy Research Inst., Tokai, Ibaraki. Tokai Research Establishment

    1977-06-01

    It is shown that the differential non-linearity of a Wilkinson-type analog-to-digital converter (ADC) is dominated by the unbalance of even-numbered periods caused by the action of interference resulting from operation of a channel scaler. To improve this situation, new methods were tested which allow such action of interference to be dispersed. Measurements show that a differential non-linearity value of +- 0.043% is attainable for a clock rate of 300 MHz.

  7. Diffusion Weighted Imaging of the Uterus: Regional ADC Variation with Oral Contraceptive Usage and Comparison with Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Messiou, Christina; Morgan, Veronica A.; Silva, Sonali S. de; Souza, Nandita M. de (Cancer Research UK Clinical Magnetic Resonance Research Group, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom)); Ind, Thomas E. (Dept. of Gynaecology and Obstetrics, St George' s Hospital NHS Trust, London (United Kingdom))

    2009-07-15

    Background: There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. Purpose: To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Material and Methods: Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCp.A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. Results: The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (P<0.001). The junctional zone was seen as a band of restricted diffusion between endometrium and outer myometrium. The ADC value of the junctional zone of the uterus was significantly greater (P<0.001) in patients taking the OCP than those patients not taking the OCp.There was no significant affect of the OCP on the ADC values of other uterine zones. Conclusion: The zonal anatomy of the uterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging

  8. Diffusion Weighted Imaging of the Uterus: Regional ADC Variation with Oral Contraceptive Usage and Comparison with Cervical Cancer

    International Nuclear Information System (INIS)

    Messiou, Christina; Morgan, Veronica A.; Silva, Sonali S. de; Souza, Nandita M. de; Ind, Thomas E.

    2009-01-01

    Background: There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. Purpose: To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Material and Methods: Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCp.A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. Results: The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (P<0.001). The junctional zone was seen as a band of restricted diffusion between endometrium and outer myometrium. The ADC value of the junctional zone of the uterus was significantly greater (P<0.001) in patients taking the OCP than those patients not taking the OCp.There was no significant affect of the OCP on the ADC values of other uterine zones. Conclusion: The zonal anatomy of the uterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging

  9. Diffusion weighted MRI and 18F-FDG PET/CT in non-small cell lung cancer (NSCLC): Does the apparent diffusion coefficient (ADC) correlate with tracer uptake (SUV)?

    International Nuclear Information System (INIS)

    Regier, M.; Derlin, T.; Schwarz, D.; Laqmani, A.; Henes, F.O.; Groth, M.; Buhk, J.-H.; Kooijman, H.; Adam, G.

    2012-01-01

    Introduction: To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). Materials and methods: 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm 2 ) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV mean ) and maximum (SUV max ) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC mean ) and minimum ADC (ADC min ) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland–Altman and regression analysis were assessed. Results: Data analysis revealed a significant inverse correlation of the ADC min and SUV max (r = −0.46; p = 0.032). Testing the correlation of the ADC min and SUV max for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r = −0.47; p = 0.03) and squamouscell carcinomas (r = −0.71; p = 0.002), respectively. No significant correlation was found for the comparison of ADC min and SUV mean (r = −0.29; p = 0.27), ADC mean vs. SUV mean (r = −0.28; p = 0.31) or ADC mean vs. SUV max (r = −0.33; p = 0.23). The κ-value of 0.88 indicated a good agreement between both observers. Conclusion: This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC

  10. Application of ADC measurement in characterization of renal cell carcinomas with different pathological types and grades by 3.0 T diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Xiaoduo, E-mail: yxd98@yahoo.com.cn [Department of Diagnostic Radiology, Cancer Institute and Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing (China); Lin, Meng, E-mail: linmeng77xp@yahoo.com.cn [Department of Diagnostic Radiology, Cancer Institute and Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing (China); Ouyang, Han, E-mail: hbybj@sohu.com [Department of Diagnostic Radiology, Cancer Institute and Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing (China); Zhou, Chunwu, E-mail: cjr.zhouchunwu@163.vip.com [Department of Diagnostic Radiology, Cancer Institute and Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing (China); Zhang, Hongtu, E-mail: zhanghongtu1010@yahoo.com.cn [Department of Pathology, Cancer Institute and Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing (China)

    2012-11-15

    Purpose: To test the feasibility of apparent diffusion coefficient (ADC) value obtained with 3.0 T diffusion-weighted imaging (DWI) in the characterization of renal cell carcinomas (RCC) with different pathological subtypes and grades. Materials and methods: A total of 137 patients who were diagnosed with RCC and underwent DWI were included in this study. The diagnosis was confirmed by pathological examination of surgical specimens. Images of DWI were obtained with b values of 0 and 800 s/mm{sup 2}. The ADC values in the solid area of tumors and in the corresponding regions of contralateral normal renal parenchyma were measured and analyzed statistically. Results: The mean ADC value was significantly lower in RCC (1.381 {+-} 0.444 Multiplication-Sign 10{sup -3} mm{sup 2}/s) than in normal renal parenchyma (2.232 {+-} 0.221 Multiplication-Sign 10{sup -3} mm{sup 2}/s) (P < 0.001). The ADC value was also statistically different between clear cell RCC (CCRCC) and non-CCRCC, and between different grades of CCRCC except grade I vs II and grade III vs IV. Conclusion: ADC measurement on 3.0 T DWI provides useful information in diagnostic work-up of RCC in terms of differentiation of RCC and normal renal parenchyma, and characterization of RCC with different pathological subtypes and grades.

  11. A 10-bit 50-MS/s subsampling pipelined ADC based on SMDAC and opamp sharing

    Energy Technology Data Exchange (ETDEWEB)

    Chen Lijie; Zhou Yumei; Wei Baoyue, E-mail: frankdhz@yahoo.com.cn [Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029 (China)

    2010-11-15

    This paper describes a 10-bit, 50-MS/s pipelined A/D converter (ADC) with proposed area- and power-efficient architecture. The conventional dedicated sample-hold-amplifier (SHA) is eliminated and the matching requirement between the first multiplying digital-to-analog converter (MDAC) and sub-ADC is also avoided by using the SHA merged with the first MDAC (SMDAC) architecture, which features low power and stabilization. Further reduction of power and area is achieved by sharing an opamp between two successive pipelined stages, in which the effect of opamp offset and crosstalk between stages is decreased. So the 10-bit pipelined ADC is realized using just four opamps. The ADC demonstrates a maximum signal-to-noise distortion ratio and spurious free dynamic range of 52.67 dB and 59.44 dB, respectively, with a Nyquist input at full sampling rate. Constant dynamic performance for input frequencies up to 49.7 MHz, which is the twofold Nyquist rate, is achieved at 50 MS/s. The ADC prototype only occupies an active area of 1.81 mm{sup 2} in a 0.35 {mu}m CMOS process, and consumes 133 mW when sampling at 50 MHz from a 3.3-V power supply.

  12. Data monitoring system for PV solar generators

    International Nuclear Information System (INIS)

    Stoev, M.; Katerski, A.; Williams, A.

    2000-01-01

    The two 1.5 kWp photovoltaic (PV) solar generators are installed and the new PC data monitoring system is developed by applying EC standards for European Solar Test Installation (ESTI). The schematic system diagram of PV generator is presented. The recording parameters for analytical and global monitoring are discussed. The meteorological data from ESTI sensors, temperature sensor and electrical data from inverter and calibrated shunt are stored via analog digital converters (ADC) on a hard disk of data storage PC. Data Logger and Monitor software for automatic data acquisition, treatment and visual distance control of all output PV data from PV solar generator has been created

  13. An undersampling 14-bit cyclic ADC with over 100-dB SFDR

    Energy Technology Data Exchange (ETDEWEB)

    Li Weitao; Li Fule; Guo Dandan; Zhang Chun; Wang Zhihua, E-mail: liwt07@mails.tsinghua.edu.c [Institute of Microelectronics, Tsinghua University, Beijing 100084 (China)

    2010-02-15

    A high linearity, undersampling 14-bit 357 kSps cyclic analog-to-digital convert (ADC) is designed for a radio frequency identification transceiver system. The passive capacitor error-average (PCEA) technique is adopted for high accuracy. An improved PCEA sampling network, capable of eliminating the crosstalk path of two pipelined stages, is employed. Opamp sharing and the removal of the front-end sample and hold amplifier are utilized for low power dissipation and small chip area. An additional digital calibration block is added to compensate for the error due to defective layout design. The presented ADC is fabricated in a 180 nm CMOS process, occupying 0.65 x 1.6 mm{sup 2}. The input of the undersampling ADC achieves 15.5 MHz with more than 90 dB spurious free dynamic range (SFDR), and the peak SFDR is as high as 106.4 dB with 2.431 MHz input. (semiconductor integrated circuits)

  14. Design and implementation of an MCA card with double ADC for nuclear radiation analysis

    International Nuclear Information System (INIS)

    Razanabololona, V.H.

    2001-01-01

    The rapid development of technology has triggered several interesting trends in nuclear instrumentation. In particular, the introduction of add-on cards that can serve as multichannel analyzer and offer adequate performance for most of the nuclear applications. The purpose of this thesis has been the design of a multichannel analyser inserted into microcomputer. The originality of this prototype MCA card with its innovative concept is the use of two analog digital converters or ADC of which the objective is to reduce to minima the lost of pulses during the acquisition and the signals processing. The first ADC works as the main converter (or master) and the second ADC the slave converter. The first ADC begins the first signals acquisition, while it will be busy for the processing, the second ADC continues the acquisition, thus there will be no lost pulses or precisely lost of pulses will be reduced to minima.The three main points for a multichannel analyzer will be studied such a the pile-up, the differential non-linearity or 'DNL' and the dead time. In the first part of this thesis the function of the MCA has been described and the different roles of the composed modules have been developed. In the second part, spectra analysis has been done with the MCA prototype as well the comparison with other MCAs such as MCAs S100, TISA, MCA35+, and the Inspector. [fr

  15. Value of apparent diffusion coefficient (ADC) in assessing radiotherapy and chemotherapy success in cervical cancer.

    Science.gov (United States)

    Fu, Zhan-Zhao; Peng, Yong; Cao, Li-Yan; Chen, Yan-Sheng; Li, Kun; Fu, Bao-Hong

    2015-06-01

    We investigated the clinical significance of apparent diffusion coefficient (ADC) values in diffusion-weighted magnetic resonance imaging (DWI) in monitoring the efficacy of radiotherapy (RT) and chemotherapy (CT) treatments in cervical cancer. In order to identify relevant high quality clinical cohort studies reporting the use of DWI in cervical cancers, the following electronic databases in English and Chinese languages were comprehensively searched: MEDLINE, Science Citation Index database, Cochrane Library Database, PubMed, Embase, CINAHL, and Current Contents Index; Chinese Biomedical Database, Chinese Journal Full-Text Database. All selected studies were published prior to March 2014, and data extracted from these studies were analyzed using STATA 12.0 statistical software. We initially retrieved 196 articles (79 Chinese articles and 117 English articles) through database searches and finally selected sixteen cohort studies for this meta-analysis. The 16 studies contained a combined total of 517 subjects, and all selected studies reported the mean ADC value (10(-3) mm(2)/s) in DWI in cervical cancer patients treated with RT and CT. Combined standardized mean difference (SMD) suggested that the mean post-RT and mean post-CT ADC values were significantly higher than the mean pre-RT and mean pre-CT ADC values, respectively, in cervical cancer patients (SMD=2.95, 95% CI=2.19-3.72, P900 (SMD=2.55, 95% CI=1.78-3.32, P<0.001). The mean ADC value in patients without residual tumor post-RT and post-CT treatment was significantly higher than seen in patients with residual tumors (SMD=0.80, 95% CI=0.49-1.12, P<0.001). Our meta-analysis revealed a significant correlation between mean ADC values and the clinical response to RT and CT treatment. Thus, ADC values in DWI may be effective in evaluating the clinical outcome of treatments in cervical cancer patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Quantitative evaluation of bone metastases from prostate cancer with simultaneous [18F] choline PET/MRI. Combined SUV and ADC analysis

    International Nuclear Information System (INIS)

    Wetter, A.; Lipponer, C.; Nensa, F.; Schlosser, T.W.; Lauenstein, T.C.; Heusch, P.; Ruebben, H.; Poeppel, T.D.; Nagarajah, J.

    2014-01-01

    To quantitatively analyze bone metastases from prostate cancer and correlate the apparent diffusion coefficients (ADCs) and standardized uptake values (SUVs). Fifty-five patients with biopsy-proven prostate cancer or suspected recurrent prostate cancer were examined with simultaneous [ 18 F] choline Positron emission tomography (PET)/MRI at 3 T. In 11 patients, thirty-two PET-positive bone lesions could be identified that were located in the field-of-view of the Diffusion weighted imaging-sequence. Region-of-interest and volume-of-interest analyses were performed to measure the mean and minimal ADCs and to assess maximum and mean SUVs of every bone lesion. Correlations between maximum and mean SUVs and mean and minimal ADCs were calculated. The SUV max of all lesions was 5.5 ± 3.1 (mean ± SD). The SUV mean was 1.8 ± 0.9. The mean ADC (ADC mean ) of all lesions was 0.67 ± 0.13 x 10 -3 mm 2 /s. The minimal ADC (ADC min ) of all lesions was 0.56 ± 0.14 x 10 -3 mm 2 /s. There was a moderate but significant inverse correlation of SUV max vs. ADC mean with a correlation coefficient of -0.4 (p=0.02). There was also a significant inverse correlation of SUV max vs. ADC min with r=-0.41 (p=0.02). Our initial results demonstrate a moderate but significant inverse correlation between increased choline metabolism and ADC values of bone metastases from prostate cancer. Further research on a multimodality approach using simultaneous PET/MRI in bone metastasis of prostate cancer seems to be justified. (author)

  17. Brain development during the first year of life. Quantitative assessment with ADC imaging

    International Nuclear Information System (INIS)

    Okuda, Yasuyuki

    1994-01-01

    Brain development during the first year of life was assessed quantitatively using apparent diffusion coefficient (ADC) images constructed from diffusion-weighted MR image data. The imaging plane was coronal at the section of the pons. The cerebral peduncle, internal capsule, corona radiata, superior longitudinal fasciculus and thalamus were selected for evaluation of their ADC values. A diffusion sensitive gradient was added in the anteroposterior direction. Thus the orientation of nerve fibers in the cerebral peduncle, internal capsule and corona radiata was perpendicular to it, and that in the superior longitudinal fasciculus was parallel to it. In neonates, the cerebral peduncle and internal capsule, having been moderately myelinated at birth, showed the slowest diffusion. The corona radiata and superior longitudinal fasciculus, having been unmyelinated at birth, showed the fastest diffusion. The thalamus had intermediate diffusion. These neonatal diffusions tended to be promptly restricted within the first five months, followed by additional slight restriction thereafter. ADC values in the first year were significantly reduced in all regions compared with those in the neonatal period, particularly in the corona radiata and thalamus. This study showed that ADC analysis can estimate normal brain development in detail and might be useful for investigating various neonatal brain diseases. (author)

  18. Integrating a sampling oscilloscope card and spectroscopy ADCs in a data acquisition system

    CERN Document Server

    Maartensson, L

    2001-01-01

    A high-rate sampling oscilloscope card has been integrated into an existing data acquisition system for spectroscopy ADCs. Experiments where pulse-shape analyses are important have then been made possible. Good performance characteristics of the integrated system have been achieved. Spectroscopy ADC data together with pulse-shape data sampled 512 times at 100 MHz are saved to hard disk at event rates up to about 1 kHz with low dead time losses.

  19. Generation and Analysis of Constrained Random Sampling Patterns

    DEFF Research Database (Denmark)

    Pierzchlewski, Jacek; Arildsen, Thomas

    2016-01-01

    Random sampling is a technique for signal acquisition which is gaining popularity in practical signal processing systems. Nowadays, event-driven analog-to-digital converters make random sampling feasible in practical applications. A process of random sampling is defined by a sampling pattern, which...... indicates signal sampling points in time. Practical random sampling patterns are constrained by ADC characteristics and application requirements. In this paper, we introduce statistical methods which evaluate random sampling pattern generators with emphasis on practical applications. Furthermore, we propose...... algorithm generates random sampling patterns dedicated for event-driven-ADCs better than existed sampling pattern generators. Finally, implementation issues of random sampling patterns are discussed....

  20. A new BIST scheme for low-power and high-resolution DAC testing

    Directory of Open Access Journals (Sweden)

    H. Li

    2003-01-01

    Full Text Available A BIST scheme for testing on chip DAC is presented in this paper. We discuss the generation of on chip testing stimuli and the measurement of digital signals with a narrow-band digital filter. We validate the scheme with software simulation and point out the possibility of ADC BIST with verified DACicus-journals.

  1. Treatment with the C5a receptor antagonist ADC-1004 reduces myocardial infarction in a porcine ischemia-reperfusion model

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2010-09-01

    Full Text Available Abstract Background Polymorphonuclear neutrophils, stimulated by the activated complement factor C5a, have been implicated in cardiac ischemia/reperfusion injury. ADC-1004 is a competitive C5a receptor antagonist that has been shown to inhibit complement related neutrophil activation. ADC-1004 shields the neutrophils from C5a activation before they enter the reperfused area, which could be a mechanistic advantage compared to previous C5a directed reperfusion therapies. We investigated if treatment with ADC-1004, according to a clinically applicable protocol, would reduce infarct size and microvascular obstruction in a large animal myocardial infarct model. Methods In anesthetized pigs (42-53 kg, a percutaneous coronary intervention balloon was inflated in the left anterior descending artery for 40 minutes, followed by 4 hours of reperfusion. Twenty minutes after balloon inflation the pigs were randomized to an intravenous bolus administration of ADC-1004 (175 mg, n = 8 or saline (9 mg/ml, n = 8. Area at risk (AAR was evaluated by ex vivo SPECT. Infarct size and microvascular obstruction were evaluated by ex vivo MRI. The observers were blinded to the treatment at randomization and analysis. Results ADC-1004 treatment reduced infarct size by 21% (ADC-1004: 58.3 ± 3.4 vs control: 74.1 ± 2.9%AAR, p = 0.007. Microvascular obstruction was similar between the groups (ADC-1004: 2.2 ± 1.2 vs control: 5.3 ± 2.5%AAR, p = 0.23. The mean plasma concentration of ADC-1004 was 83 ± 8 nM at sacrifice. There were no significant differences between the groups with respect to heart rate, mean arterial pressure, cardiac output and blood-gas data. Conclusions ADC-1004 treatment reduces myocardial ischemia-reperfusion injury and represents a novel treatment strategy of myocardial infarct with potential clinical applicability.

  2. High Performance ADC for Reconfigurable/Reprogrammable Communication Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop Group will develop a 3X improvement in sampling resolution over current state-of-the art analog-to-digital converter (ADC) technology to support...

  3. Fast high resolution ADC based on the flash type with a special error correcting technique

    Energy Technology Data Exchange (ETDEWEB)

    Xiao-Zhong, Liang; Jing-Xi, Cao [Beijing Univ. (China). Inst. of Atomic Energy

    1984-03-01

    A fast 12 bits ADC based on the flash type with a simple special error correcting technique which can effectively compensate the level drift of the discriminators and the droop of the stretcher voltage is described. The DNL is comparable with the Wilkinson's ADC and long term drift is far better than its.

  4. Design and construction of the 8K multi-channel gamma spectrometer module (ADC+MCD)

    International Nuclear Information System (INIS)

    Vu Xuan Cach; Hoang Thi Ngoc Bich; Truong Van Dat; Pham Ngoc Tuan; Dang Lanh; Tuong Thi Thu Huong; Nguyen Xuan Hai

    2007-01-01

    A multichannel pulse-height analyzer system (MCA) consists of an ADC with 8192 channel performance, a histogramming memory, and a visual display of the histogram, implemented on a Personal Computer (PC). The purpose of the analog-to-digital converter (ADC) is to measure the maximum amplitude of an analog pulse, and convert that value into a digital number. This digital output is a proportional representation of the analog amplitude at the ADC input. The digital ADC outputs are stored in a histogram memory, where each bin represents a pulse height interval and the number of events in each bin represents the number of events in that interval. The combination of ADC, histogramming memory and display functions are the minimum to constitute a multichannel analyzer or MCA based on PC. It is designed and fabricated on a single NIM module. The communication between MCA module and PC implements via USB bus. In our application, performance of the USB standard version 1.1 is good enough for purposes. The application program was designed in LabWIEW 8.0 software. This application is the main display and acquisition software for the MCA module. It is compatible with Windows 98SE/XP. The libraries USB driver, with their supporting files, are in the FTD2XX driver DLL Package and D2XX function 7.0 for LabWIEW supporting. These libraries are used to write custom code to control the MCA module. The 8K MCA module has the main following hardware specifications: ADC Successive-approximation type with sliding scale linearization; resolution: 8192 channels; dead time per event: 5 μs, including memory transfer; integral nonlinearity: ±0.025% over the top 98% of the dynamic range; differential nonlinearity: < ±1% over the top 98% of the dynamic range; data memory: 224 counts per channel (16 millions counts); presets; Real Time/Live Time: 1 to 232(s), Multiples of 1 s; ADC LLD and ULD Aajustable from 0 to 100% of full scale via hardware control; input accepts positive unipolar pulses in

  5. Quantitative evaluation of benign and malignant vertebral fractures with diffusion-weighted MRI: what is the optimum combination of b values for ADC-based lesion differentiation with the single-shot turbo spin-echo sequence?

    Science.gov (United States)

    Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Duerr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea

    2014-09-01

    The purpose of our study was to determine the optimum combination of b values for calculating the apparent diffusion coefficient (ADC) using a diffusion-weighted (DW) single-shot turbo spin-echo (TSE) sequence in the differentiation between acute benign and malignant vertebral body fractures. Twenty-six patients with osteoporotic (mean age, 69 years; range, 31.5-86.2 years) and 20 patients with malignant vertebral fractures (mean age, 63.4 years; range, 24.7-86.4 years) were studied. T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW single-shot TSE sequence at different b values (100, 250, 400, and 600 s/mm(2)) was applied. On the DW images for each evaluated fracture, an ROI was manually adapted to the area of hyperintense signal intensity on STIR-hypointense signal on T1-weighted images. For each ROI, nine different combinations of two, three, and four b values were used to calculate the ADC using a least-squares algorithm. The Student t test and Mann-Whitney U test were used to determine significant differences between benign and malignant fractures. An ROC analysis and the Youden index were used to determine cutoff values for assessment of the highest sensitivity and specificity for the different ADC values. The positive (PPV) and negative predictive values (NPV) were also determined. All calculated ADCs (except the combination of b = 400 s/mm(2) and b = 600 s/mm(2)) showed statistically significant differences between benign and malignant vertebral body fractures, with benign fractures having higher ADCs than malignant ones. The use of higher b values resulted in lower ADCs than those calculated with low b values. The highest AUC (0.85) showed the ADCs calculated with b = 100 and 400 s/mm(2), and the second highest AUC (0.829) showed the ADCs calculated with b = 100, 250, and 400 s/mm(2). The Youden index with equal weight given to sensitivity and specificity suggests use of an ADC calculated with b = 100, 250, and 400 s/mm(2) (cutoff

  6. Value of apparent diffusion coefficient (ADC) in evaluating response ...

    African Journals Online (AJOL)

    Objective. To determine whether the apparent diffusion coefficient (ADC) value obtained by diffusion-weighted magnetic resonance imaging (DW-MRI) can be used as a reliable detector of response of carcinoma of the cervix treated with chemoradiotherapy, compared with conventional. T2-weighted MRI. Design.

  7. A digital multi-channel spectroscopy system with 100 MHz flash ADC module for the GENIUS-TF and GENIUS projects

    International Nuclear Information System (INIS)

    Kihm, T.; Bobrakov, V.F.; Klapdor-Kleingrothaus, H.V.

    2003-01-01

    In this paper we present the first results of applying a digital processing technology in low-level gamma spectroscopy with HPGE detectors. An experimental gamma spectrometer using Flash ADC module is built and tested. The test system is now under development and shows major advantages over the traditional analog technologies. It will be installed for the GENIUS-TF and GENIUS projects in Gran-Sasso in early 2003

  8. Continuous time sigma delta ADC design and non-idealities analysis

    International Nuclear Information System (INIS)

    Yuan Jun; Chen Zhenhai; Yang Yintang; Zhang Zhaofeng; Wu Jun; Wang Chao; Qian Wenrong

    2011-01-01

    A wide bandwidth continuous time sigma delta ADC is implemented in 130 nm CMOS. A detailed non-idealities analysis (excess loop delay, clock jitter, finite gain and GBW, comparator offset and DAC mismatch) is performed developed in Matlab/Simulink. This design is targeted for wide bandwidth applications such as video or wireless base-stations. Athird-order continuous time sigma delta modulator comprises a third-order RC operational-amplifier-based loop filter and 3-bit internal quantizer operated at 512 MHz clock frequency. The sigma delta ADC achieves 60 dB SNR and 59.3 dB SNDR over a 16-MHz signal band at an OSR of 16. The power consumption of the CT sigma delta modulator is 22 mW from the 1.2-V supply. (semiconductor integrated circuits)

  9. Recombinant Chimpanzee Adenovirus Vaccine AdC7-M/E Protects against Zika Virus Infection and Testis Damage.

    Science.gov (United States)

    Xu, Kun; Song, Yufeng; Dai, Lianpan; Zhang, Yongli; Lu, Xuancheng; Xie, Yijia; Zhang, Hangjie; Cheng, Tao; Wang, Qihui; Huang, Qingrui; Bi, Yuhai; Liu, William J; Liu, Wenjun; Li, Xiangdong; Qin, Chuan; Shi, Yi; Yan, Jinghua; Zhou, Dongming; Gao, George F

    2018-03-15

    The recent outbreak of Zika virus (ZIKV) has emerged as a global health concern. ZIKV can persist in human semen and be transmitted by sexual contact, as well as by mosquitoes, as seen for classical arboviruses. We along with others have previously demonstrated that ZIKV infection leads to testis damage and infertility in mouse models. So far, no prophylactics or therapeutics are available; therefore, vaccine development is urgently demanded. Recombinant chimpanzee adenovirus has been explored as the preferred vaccine vector for many pathogens due to the low preexisting immunity against the vector among the human population. Here, we developed a ZIKV vaccine based on recombinant chimpanzee adenovirus type 7 (AdC7) expressing ZIKV M/E glycoproteins. A single vaccination of AdC7-M/E was sufficient to elicit potent neutralizing antibodies and protective immunity against ZIKV in both immunocompetent and immunodeficient mice. Moreover, vaccinated mice rapidly developed neutralizing antibody with high titers within 1 week postvaccination, and the elicited antiserum could cross-neutralize heterologous ZIKV strains. Additionally, ZIKV M- and E-specific T cell responses were robustly induced by AdC7-M/E. Moreover, one-dose inoculation of AdC7-M/E conferred mouse sterilizing immunity to eliminate viremia and viral burden in tissues against ZIKV challenge. Further investigations showed that vaccination with AdC7-M/E completely protected against ZIKV-induced testicular damage. These data demonstrate that AdC7-M/E is highly effective and represents a promising vaccine candidate for ZIKV control. IMPORTANCE Zika virus (ZIKV) is a pathogenic flavivirus that causes severe clinical consequences, including congenital malformations in fetuses and Guillain-Barré syndrome in adults. Vaccine development is a high priority for ZIKV control. In this study, to avoid preexisting anti-vector immunity in humans, a rare serotype chimpanzee adenovirus (AdC7) expressing the ZIKV M

  10. Design And Construction Of The 8K Multi-Channel GAMMA Spectrometer Module (AMPLIFIER+ADC+MCD)

    International Nuclear Information System (INIS)

    Truong Van Dat; Hoang Thi Ngoc Bich; Pham Ngoc Tuan; Dang Lanh; Tuong Thi Thu Huong; Vu Xuan Cach

    2007-01-01

    A multichannel pulse-height analyzer system (MCA) consists of an spectroscopy Amplifier, ADC with 8192 channel performance, a histogramming memory, and a visual display of the histogram implemented on a Personal Computer (PC). The purpose of the analog-to-digital converter (ADC) is to measure the maximum amplitude of an analog pulse, and convert that value into a digital number. This digital output is a proportional representation of the analog amplitude at the ADC input. The digital ADC outputs are stored in a histogram memory, where each bin represents a pulse height interval and the number of events in each bin represents the number of events in that interval. The combination of ADC, histogramming memory and display functions are the minimum to constitute a multichannel analyzer or MCA based on PC. It is designed and fabricated on a single NIM module. The communication between MCA module and PC implements via USB bus. In our application, performance of the USB standard version 1.1 is good enough for purposes. The application program was designed in LabWIEW 8.0 software. This application is the main display and acquisition software for the MCA module. It is compatible with Windows 98SE/XP. The libraries USB driver, with their supporting files, are in the FTD2XX driver DLL Package and D2XX function 7.0 for LabWIEW supporting. These libraries are used to write custom code to control the MCA module. (author)

  11. Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients

    International Nuclear Information System (INIS)

    Peng, Steven Shinn-Forng; Jeng, Yung-Ming; Hsu, Wen-Ming; Ho, Ming-Chih; Yang, Justin Cheng-Ta

    2015-01-01

    Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). Thirty-two patients with biliary atresia (BA; mean age 461 days, range 11-4616 days) received magnetic resonance examinations from March 2009 to August 2013. A free-breathing DWMRI sequence was performed with the single-shot echo-planar imaging technique with b = 0 and 500 s/mm 2 in all 32 BA patients and 24 controls. We used the ordinal logistic regression test and Spearman rank correlation test to analyse the relationships between the MRSPBC and METAVIR fibrosis scores and right liver-to-psoas ADC ratios (LTPARs). BA patients had significantly lower LTPARs in both hepatic lobes than controls (p < 0.01). Right LTPARs, showing moderate intraobserver agreement (intraclass correlation coefficient = 0.736) and interobserver reliability (intraclass correlation coefficient = 0.659), were negatively correlated with MRSPBC and METAVIR fibrosis scores (R 2 = 0.398, p = 0.024 and R 2 = 0.628, p < 0.001, respectively). Right LTPARs may be used for long-term follow-up of cirrhosis severity in BA patients. (orig.)

  12. Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Steven Shinn-Forng [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); Jeng, Yung-Ming [National Taiwan University, Department of Pathology, Medical College and Hospital, Taipei (China); Hsu, Wen-Ming; Ho, Ming-Chih [National Taiwan University, Department of Surgery, Medical College and Hospital, Taipei, Taiwan (China); Yang, Justin Cheng-Ta [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); National Taiwan University, Institute of Biomedical Engineering, College of Engineering and College of Medicine, Taipei (China)

    2015-10-15

    Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). Thirty-two patients with biliary atresia (BA; mean age 461 days, range 11-4616 days) received magnetic resonance examinations from March 2009 to August 2013. A free-breathing DWMRI sequence was performed with the single-shot echo-planar imaging technique with b = 0 and 500 s/mm{sup 2} in all 32 BA patients and 24 controls. We used the ordinal logistic regression test and Spearman rank correlation test to analyse the relationships between the MRSPBC and METAVIR fibrosis scores and right liver-to-psoas ADC ratios (LTPARs). BA patients had significantly lower LTPARs in both hepatic lobes than controls (p < 0.01). Right LTPARs, showing moderate intraobserver agreement (intraclass correlation coefficient = 0.736) and interobserver reliability (intraclass correlation coefficient = 0.659), were negatively correlated with MRSPBC and METAVIR fibrosis scores (R{sup 2} = 0.398, p = 0.024 and R{sup 2} = 0.628, p < 0.001, respectively). Right LTPARs may be used for long-term follow-up of cirrhosis severity in BA patients. (orig.)

  13. A 12-bit 40 MS/s pipelined ADC with over 80 dB SFDR

    Energy Technology Data Exchange (ETDEWEB)

    Wei Qi; Yin Xiumei; Han Dandan; Yang Huazhong, E-mail: q-wei05@mails.tsinghua.edu.c [Department of Electronic Engineering, Tsinghua University, Beijing 100084 (China)

    2010-02-15

    This paper describes a 12-bit 40 MS/s calibration-free pipelined analog-to-digital converter (ADC), which is optimized for high spurious free dynamic range (SFDR) performance and low power dissipation. With a 4.9 MHz sine wave input, the prototype ADC implemented in a 0.18-{mu}m 1P6M CMOS process shows measured differential nonlinearity and integral nonlinearity within 0.78 and 1.32 least significant bits at the 12-bit level without any trimming or calibration. The ADC, with a total die area of 3.1 x 2.1 mm{sup 2}, demonstrates a maximum signal-to-noise distortion ratio (SNDR) and SFDR of 66.32 and 83.38 dB, respectively, at a 4.9 MHz analog input and a power consumption of 102 mW from a 1.8 V supply. (semiconductor integrated circuits)

  14. Usefulness of Diffusion-Weighted MR Imaging for Breast Lesions: Comparing the Apparent Diffusion Coefficient (ADC) Values and the Pathologic Results

    International Nuclear Information System (INIS)

    Ahn, Hye Shin; Chang, Yun Woo; Choi, Kyung Hee; Kim, Hyun Joo; Hong, Seong Suk; Hwang, Jung Hwa; Kwon, Kui Hyang; Kim, Yong Bae

    2011-01-01

    We wanted to evaluate the ability of the apparent diffusion coefficient (ADC) values to differentiate between benign and malignant breast lesions and the normal breast parenchyma. We used breast MRI, including DWI, to obtain images of 167 breast lesions (18 benign lesions and 149 malignant lesions) of 152 women (mean age: 48.6 years, range: 24-80 years). The mean ADC values of the malignant lesions were compared to those of the benign lesions and the normal parenchyma. We compared the ADC values of IDC, DCIS and other types of breast cancer and we also compared the ADC values with the nuclear grade of IDC. The mean ADC values of the malignant lesions were lower than those of the benign lesions and the normal parenchyma (p -3 mm 2 /s for discriminating between malignant and benign lesion showed a specificity of 53% and a sensitivity of 100%, and the ADC threshold value of 1.33 X 10 -3 mm 2 /s showed a specificity of 93% and a sensitivity of 94% for discriminating between malignant and benign lesion.

  15. Two zinc-binding domains in the transporter AdcA from Streptococcus pyogenes facilitate high-affinity binding and fast transport of zinc.

    Science.gov (United States)

    Cao, Kun; Li, Nan; Wang, Hongcui; Cao, Xin; He, Jiaojiao; Zhang, Bing; He, Qing-Yu; Zhang, Gong; Sun, Xuesong

    2018-04-20

    Zinc is an essential metal in bacteria. One important bacterial zinc transporter is AdcA, and most bacteria possess AdcA homologs that are single-domain small proteins due to better efficiency of protein biogenesis. However, a double-domain AdcA with two zinc-binding sites is significantly overrepresented in Streptococcus species, many of which are major human pathogens. Using molecular simulation and experimental validations of AdcA from Streptococcus pyogenes , we found here that the two AdcA domains sequentially stabilize the structure upon zinc binding, indicating an organization required for both increased zinc affinity and transfer speed. This structural organization appears to endow Streptococcus species with distinct advantages in zinc-depleted environments, which would not be achieved by each single AdcA domain alone. This enhanced zinc transport mechanism sheds light on the significance of the evolution of the AdcA domain fusion, provides new insights into double-domain transporter proteins with two binding sites for the same ion, and indicates a potential target of antimicrobial drugs against pathogenic Streptococcus species. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.

  16. [The relevance of ADC value, T₁intensive rate and the clinical activities in ankylosing spondylitis sacroiliitis].

    Science.gov (United States)

    Zhao, Yinghua; Han, Xinai; Hu, Shaoyong; Shi, Xingliang; Zhao, Jing; Sun, Erwei; Li, Shaolin

    2014-09-23

    To evaluate the value of judging for the activity in AS by diffusion-weighted sequences (DWI) and enhance sequences MRI(DCE-MRI), to explore the correlation of Apparent diffusion coefficient(ADC) values, intensive rate and the clinical activity index in sacroiliitis (SIJ) of ankylosing spondylitis (AS). 56 patients prospectively choiced and diagnosed were divided into two groupsas, active group (n = 32) and chronic group (n = 24) by rheumatologist according to BASDAI and laboratory parameters. Twenty healthy adults were as control group. The values of ADC and intensive rate of all sacroiliac joints (SIJs) were measured on MRI. BASDAI score were got by Bath ankylosing spondylitis disease activity index. ESR, CPR and were got by laboratory. Statisticaly to analysis whether the parameters were significantly different amang AS active, chronic, and the control group. To assess the correlation of the values of ADC, intensive rate and BASDAI score, ESR, CPR and in SIJ. the values of ADC and intensive rate were significantly different among AS active, chronic and the control group. There were the significant correlation between the values of ADC, intensive rate and BASDAI score. Diffusion-weighted sequences and Contrast-enhanced sequences is superior to other methods in judging the activity in AS.combined with clinical activity index, the accuracy can significantly be improved to explore whether the activities of AS are.

  17. ADC histogram analysis of muscle lymphoma - Correlation with histopathology in a rare entity.

    Science.gov (United States)

    Meyer, Hans-Jonas; Pazaitis, Nikolaos; Surov, Alexey

    2018-06-21

    Diffusion weighted imaging (DWI) is able to reflect histopathology architecture. A novel imaging approach, namely histogram analysis, is used to further characterize lesion on MRI. The purpose of this study is to correlate histogram parameters derived from apparent diffusion coefficient- (ADC) maps with histopathology parameters in muscle lymphoma. Eight patients (mean age 64.8 years, range 45-72 years) with histopathologically confirmed muscle lymphoma were retrospectively identified. Cell count, total nucleic and average nucleic areas were estimated using ImageJ. Additionally, Ki67-index was calculated. DWI was obtained on a 1.5T scanner by using the b values of 0 and 1000 s/mm2. Histogram analysis was performed as a whole lesion measurement by using a custom-made Matlabbased application. The correlation analysis revealed statistically significant correlation between cell count and ADCmean (p=-0.76, P=0.03) as well with ADCp75 (p=-0.79, P=0.02). Kurtosis and entropy correlated with average nucleic area (p=-0.81, P=0.02, p=0.88, P=0.007, respectively). None of the analyzed ADC parameters correlated with total nucleic area and with Ki67-index. This study identified significant correlations between cellularity and histogram parameters derived from ADC maps in muscle lymphoma. Thus, histogram analysis parameters reflect histopathology in muscle tumors. Advances in knowledge: Whole lesion ADC histogram analysis is able to reflect histopathology parameters in muscle lymphomas.

  18. Combined apparent diffusion coefficient value (ADC and 1H magnetic resonance spectroscopy (MRS in breast lesions: Benefits and limitations

    Directory of Open Access Journals (Sweden)

    Enass M. Khattab

    2018-06-01

    Conclusion: A great advantage of ADC value is the significant difference between benign and malignant lesions, because of this it plays an important role in characterization of breast lesions. MRS is the only in vivo technique which can detect tissue metabolites. In our study combined MRS with ADC value increased sensitivity in detecting lesions, while the specificity remained at lower level than that of the ADC value alone.

  19. Diagnosis of early sacroiliitis in seronegative spondyloarthropathies by DWI and correlation of clinical and laboratory findings with ADC values

    Energy Technology Data Exchange (ETDEWEB)

    Gezmis, Esin; Donmez, Fuldem Y., E-mail: fuldemyildirim@yahoo.com; Agildere, Muhtesem

    2013-12-01

    Purpose: Sacroiliitis is one of the diagnostic criteria of seronegative SpA. The purpose of our study is to show the signal characteristics of the sacral and iliac surfaces by DWI which may contribute in early diagnosis of sacroiliitis and investigate the correlation between ADC values and clinical and laboratory parameters. Materials and methods: 62 patients with inflammatory low back pain, with a history or suspect of seronegative SpA are enrolled into the study. 40 age and sex-matched subjects without SpA constituted the control group. After obtaining routine T1 and T2 weighted sequences, echo planar imaging at b values of 0, 400 and 800 was performed. ADC values on both surfaces of the both sacroiliac joints were measured in all subjects. The CRP and sedimentation results and the presence of arthritis and enthesitis were also correlated with the ADC values. Results: ADC values on both surfaces of the both sacroiliac joints were found 0.23 × 10{sup −3} mm{sup 2}/sn in the control group. In the patient group, mean ADC value of 0.48 × 10{sup −3} mm{sup 2}/sn was obtained (p < 0.001), which was statistically significant, compatible with the increased diffusion due to medullary edema in early sacroiliitis. There was a slight correlation between CRP and ADC values; presumed to be showing the relation between the activity of the disease and the active inflammation on DWI. There was no correlation between arthritis and enthesitis and the ADC values (p > 0.001). Conclusion: DWI, by measuring ADC values, adds significant information in the early diagnosis of sacroiliitis and may help to evaluate the efficiency of the treatment.

  20. Quantitative diffusion tensor MR imaging of the brain: field strength related variance of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) scalars

    International Nuclear Information System (INIS)

    Huisman, Thierry A.G.M.; Loenneker, Thomas; Barta, Gerd; Bellemann, Matthias E.; Hennig, Juergen; Fischer, Joachim E.; Il'yasov, Kamil A.

    2006-01-01

    The objectives were to study the ''impact'' of the magnetic field strength on diffusion tensor imaging (DTI) metrics and also to determine whether magnetic-field-related differences in T2-relaxation times of brain tissue influence DTI measurements. DTI was performed on 12 healthy volunteers at 1.5 and 3.0 Tesla (within 2 h) using identical DTI scan parameters. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured at multiple gray and white matter locations. ADC and FA values were compared and analyzed for statistically significant differences. In addition, DTI measurements were performed at different echo times (TE) for both field strengths. ADC values for gray and white matter were statistically significantly lower at 3.0 Tesla compared with 1.5 Tesla (% change between -1.94% and -9.79%). FA values were statistically significantly higher at 3.0 Tesla compared with 1.5 Tesla (% change between +4.04 and 11.15%). ADC and FA values are not significantly different for TE=91 ms and TE=125 ms. Thus, ADC and FA values vary with the used field strength. Comparative clinical studies using ADC or FA values should consequently compare ADC or FA results with normative ADC or FA values that have been determined for the field strength used. (orig.)

  1. A digital multi-channel spectroscopy system with 100 MHz flash ADC module for the GENIUS-TF and GENIUS projects

    OpenAIRE

    Kihm, T.; Bobrakov, V. F.; Klapdor-Kleingrothaus, H. V.

    2003-01-01

    In this paper we will present the first results of applying a digital processing technology in low-level gamma spectroscopy with HPGE detectors. An experimental gamma spectrometer using Flash ADC module is built and tested. The test system is now under development and shows major advantages over the traditional analog technologies. It will be installed for the GENIUS-TF and GENIUS projects in Gran-Sasso in early 2003.

  2. Design of eight-channel ADC card for GHz signal conversion

    CERN Document Server

    Habib, Samer Bou; Jalmuzna, Wojciech; Jezynski, Tomasz

    2011-01-01

    This paper describes the design of an eight-channel ATCA card suited for direct analog-to-digital conversion of 1.3 GHz signals with a maximum ADC clock frequency of 500 MHz. The undersampling operation is used for signal conversion. This card was designed for the needs of the LLRF system of the FLASH and XFEL accelerators. The designed module consists of a main ATCA board with eight ADCs, FPGA unit, memory, power supply and diagnostic circuits. The main ATCA card allows connecting a daughter board with IPMI, CPU and fast interfaces for communication purposes. This paper describes such issues as system organization allowing acquisition of data at such high data rates, circuit synchronization by high-quality clock signals, CPU and connectivity features, 20-layer PCB design and techniques used for high-frequency signals transmission and matching.

  3. Optimization of Modulator and Circuits for Low Power Continuous-Time Delta-Sigma ADC

    DEFF Research Database (Denmark)

    Marker-Villumsen, Niels; Bruun, Erik

    2014-01-01

    This paper presents a new optimization method for achieving a minimum current consumption in a continuous-time Delta-Sigma analog-to-digital converter (ADC). The method is applied to a continuous-time modulator realised with active-RC integrators and with a folded-cascode operational transconduc...... levels are swept. Based on the results of the circuit analysis, for each modulator combination the summed current consumption of the 1st integrator and quantizer of the ADC is determined. By also sweeping the partitioning of the noise power for the different circuit parts, the optimum modulator...

  4. Desain Layout 1-Stage ADC Pipeline 80Msps dengan Mentor Graphics 0,35µm untuk Aplikasi Kamera Kecepatan Tinggi

    Directory of Open Access Journals (Sweden)

    Hamzah Afandi

    2012-10-01

    Full Text Available Design layout 1-stage pipeline is part of the 8-stage pipeline 80 Msps ADC. Layout 1-stage pipeline consists of 3 units : op-amp, switch capacitor, precision comparator with latch. Pipeline ADC works gradually and requires synchronization of digital output 8 stage by using a unit delay circuit (D-FF. Pipeline ADC requires pulse rate (clockgenerator to support its work. Units OP-AMP transconductance CMOS components designed with the correct specification ADC applications with capacitive loads, with a large input impedance and minimize noise. The precision comparator has Vos(offset voltage approximately equal to 0V. The capacitor switch designs use NMOS switch as a switch for the sampling and multiplying. In the sampling phase and multiplying processes, the ADC requires a clock pulse with a non-intersect mode (lapping. The width of non-overlapping period was adjusted to the time of constance in the sampling process and multiplying. The total number of each pulse period equal to 12.5 ns or equal to the frequency of 80MHz. In the 1-stage layout an additional correction capacitor was required to correct residual voltage. The total area of the layout 1-stage pipeline ADC is 1-bit 200 μm x 98μm.

  5. Low Power 2-Bit ADC Array with Serial Output, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Microwave interferometers for NASA missions such as PATH employ the GeoSTAR instrument, consisting of 600 receivers. Each receiver requires I and Q ADCs...

  6. A standardized way to select, evaluate, and test an analog-to-digital converter for ultrawide bandwidth radiofrequency signals based on user's needs, ideal, published,and actual specifications

    Science.gov (United States)

    Chang, Daniel Y.; Rowe, Neil C.

    2012-06-01

    The most important adverse impact on the Electronic Warfare (EW) simulation is that the number of signal sources that can be tested simultaneously is relatively small. When the number of signal sources increases, the analog hardware, complexity and costs grow by the order of N2, since the number of connections among N components is O(N*N) and the signal communication is bi-directional. To solve this problem, digitization of the signal is suggested. In digitizing a radiofrequency signal, an Analog-to-Digital Converter (ADC) is widely used. Most research studies on ADCs are conducted from designer/test engineers' perspective. Some research studies are conducted from market's perspective. This paper presents a generic way to select, evaluate and test ultra high bandwidth COTS ADCs and generate requirements for digitizing continuous time signals from the perspective of user's needs. Based on user's needs, as well as vendor's published, ideal and actual specifications, a decision can be made in selecting a proper ADC for an application. To support our arguments and illustrate the methodology, we evaluate a Tektronix TADC-1000, an 8-bit and 12 gigasamples per second ADC. This project is funded by JEWEL lab, NAWCWD at Point Mugu, CA.

  7. 55-mW, 1.2-V, 12-bit, 100-MSPS Pipeline ADCs for Wireless Receivers

    Science.gov (United States)

    Ito, Tomohiko; Kurose, Daisuke; Ueno, Takeshi; Yamaji, Takafumi; Itakura, Tetsuro

    For wireless receivers, low-power 1.2-V 12-bit 100-MSPS pipeline ADCs are fabricated in 90-nm CMOS technology. To achieve low-power dissipation at 1.2V without the degradation of SNR, the configuration of 2.5bit/stage is employed with an I/Q amplifier sharing technique. Furthermore, single-stage pseudo-differential amplifiers are used in a Sample-and-Hold (S/H) circuit and a 1st Multiplying Digital-to-Analog Converter (MDAC). The pseudo-differential amplifier with two-gain-stage transimpedance gain-boosting amplifiers realizes high DC gain of more than 90dB with low power. The measured SNR of the 100-MSPS ADC is 66.7dB at 1.2-V supply. Under that condition, each ADC dissipates only 55mW.

  8. Application of porous-media theory to the investigation of water ADC changes in rabbit Achilles tendon caused by tensile loading

    Science.gov (United States)

    Wellen, J.; Helmer, K. G.; Grigg, P.; Sotak, C. H.

    2004-09-01

    The water apparent diffusion coefficient (ADC) in rabbit Achilles tendon is anisotropic, diffusion-time dependent, and changes as a function of tensile load. Water ADC changes of tendon under mechanical load are thought to be due to the extrusion of water from the more restricted tendon core to a relatively unrestricted bulk phase at the periphery (rim) of the tendon. Tensile loading may influence water ADC values by changing the spatial separation of restricting barriers (e.g., increasing the tendon fibril packing density). To explore this issue, we have applied porous-media theory to the investigation of water ADC changes in rabbit Achilles tendon under two different mechanical loading conditions (a baseline condition with a minimal tensile stress and a second in which the tensile stress was approximately 1 MPa). Diffusion sensitivity was applied in directions parallel and perpendicular to the long axis of the tendon. The short diffusion-time behavior of the resulting time-dependent ADC curves was used to indirectly infer information regarding the average surface area to volume ratio of the space available for molecular diffusion. From these values, we estimated a 40% reduction in volume available for diffusion in the perpendicular direction after tensile loading, but only a 10% reduction in the parallel direction. These differences are consistent with the known geometry of the tendon microstructure and suggest an increase in fibril packing density upon loading. The long diffusion-time behavior of the time-dependent ADC curves was used to indirectly infer the tortuosity of the diffusion pathways through the interstitial space. The tortuosity in the direction perpendicular to the tendon long axis was approximately 2.5 times greater than that in the parallel direction. Stimulated-echo measurement of the ADC values at longer diffusion times resulted in T1 spin editing of water with shorter T1 values (and correspondingly lower ADC values). The resulting increase in

  9. A new architecture for low-power high-speed pipelined ADCs using double-sampling and opamp-sharing techniques

    NARCIS (Netherlands)

    Abdinia, S.; Yavari, M.

    2009-01-01

    This paper presents a low-voltage low-power pipelined ADC with 1V supply voltage in a 90nm CMOS process. A new architecture is proposed to reduce the power consumption in high-speed pipelined analog-to-digital converters (ADCs). The presented architecture utilizes a combination of two current

  10. Studying DAC capacitor-array degradation in charge-redistribution SAR ADCs

    NARCIS (Netherlands)

    Khan, M.A.; Kerkhoff, Hans G.

    2014-01-01

    In this paper, system-level behavioural models are used to simulate the aging-related degradation effects in the DAC capacitor array of a charge-redistribution successive approximation register (SAR) ADC because of the large calculation time of transistor-level aging simulators. A

  11. A Continuous-Time Delta-Sigma ADC for Portable Ultrasound Scanners

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2017-01-01

    A fully differential fourth-order 1-bit continuous-time delta-sigma ADC designed in a 65nm process for portable ultrasound scanners is presented in this paper. The circuit design, implementation and measurements on the fabricated die are shown. The loop filter consists of RC-integrators, programmable...... capacitor arrays, resistors and voltage feedback DACs. The quantizer contains a pulse generator, a high-speed clocked comparator and a pull-down clocked latch to ensure constant delay in the feedback loop. Using this implementation, a small and low-power solution required for portable ultrasound scanner...... applications is achieved. The converter has a supply voltage of 1.2V, a bandwidth of 10MHz and an oversampling ratio of 16 leading to an operating frequency of 320MHz. The design occupies a die area of 0.0175mm2. Simulations with extracted parasitics show a SNR of 45.2dB and a current consumption of 489 µ...

  12. Low Power 1-Bit ADC Array with Serial Output, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Microwave interferometers for NASA missions such as PATH and SCLP consist of up to 900 receivers. Each receiver requires I and Q ADCs (analog-to-digital converters)...

  13. A second-order ΣΔ ADC using sputtered IGZO TFTs

    CERN Document Server

    Correia, Ana Paula Pinto; Goes, João Carlos da Palma

    2016-01-01

    This book discusses the design, electrical simulation and layout of a 2nd-order ∑∆ analog-to-digital converter (ADC), using oxide thin-film transistors (TFTs) technology. The authors provide a unified view of materials science and electronics engineering, in order to guide readers from both fields through key topics. To accomplish this goal, background regarding materials, device physics, characterization techniques, circuit design and layout is given together with a detailed discussion of experimental data. The final simulation results clearly demonstrate the potential of the proposed circuit-level techniques, which enables the implementation of robust and energy efficient ADCs based on oxide TFTs, for moderate resolutions and conversion-rates. Combines materials science and electronics engineering in the same book, making it possible to obtain a general overview, from TFTs production and characterization to their integration in relatively complex circuits; Adapts an a-Si:H TFT RPI model to simulate the ...

  14. Modifications of the optical properties for DAM-ADC nuclear track detector exposed to alpha particles

    Science.gov (United States)

    Rammah, Y. S.; Awad, E. M.

    2018-05-01

    Modifications of the optical properties of diallyl maleate-allyl diglycol carbonate (DAM-ADC) nuclear detector induced by alpha particles are described. DAM-ADC samples were irradiated perpendicularly by thin 241Am disk source that emits alpha particles with 5.48 MeV. The optical absorption has been measured using the ultraviolet-visible (UV-1100) spectroscopy. It was found that DAM-ADC polymer shows substantial modifications in its optical characteristics upon irradiated with alpha particles with different energies. The optical energy band gap (Egap) for the detector was calculated for the direct and the indirect allowed transitions in K-space using two approaches (Tauc's model and absorption spectrum fitting (ASF) method). Urbach's energy (Ea), number of carbon atoms per conjugated length (N), number of carbon atoms per cluster (M), and refractive index (n) for the present samples were determined. Results reveal that the values of energy gap in direct transition are greater than those of indirect, before and after irradiation. (Egap), (Ea), (N), (M), and (n) of the present samples are changed significantly with irradiation time and value of alpha energy. Results reflect the possibility of using DAM-ADC polymer track detectors to estimate alpha particle energies using the variation of the absorbance.

  15. Attitude Determination and Control Subsystem (ADCS) Preparations for the EPOXI Flyby of Comet Hartley 2

    Science.gov (United States)

    Luna, Michael E.; Collins, Steven M.

    2011-01-01

    On November 4, 2010 the former "Deep Impact" spacecraft, renamed "EPOXI" for its extended mission, flew within 700km of comet 103P/Hartley 2. In July 2005, the spacecraft had previously imaged a probe impact of comet Tempel 1. The EPOXI flyby was the fifth close encounter of a spacecraft with a comet nucleus and marked the first time in history that two comet nuclei were imaged at close range with the same suite of onboard science instruments. This challenging objective made the function of the attitude determination and control subsystem (ADCS) critical to the successful execution of the EPOXI flyby.As part of the spacecraft flyby preparations, the ADCS operations team had to perform meticulous sequence reviews, implement complex spacecraft engineering and science activities and perform numerous onboard calibrations. ADCS contributions included design and execution of 10 trajectory correction maneuvers, the science calibration of the two telescopic instruments, an in-flight demonstration of high-rate turns between Earth and comet point, and an ongoing assessment of reaction wheel health. The ADCS team was also responsible for command sequences that included updates to the onboard ephemeris and sun sensor coefficients and implementation of reaction wheel assembly (RWA) de-saturations.

  16. High precision 16K, 16 channel peak sensing CAMAC ADC

    International Nuclear Information System (INIS)

    Jain, Mamta; Subramaniam, E.T

    2013-01-01

    A high density, peak sensing, analog to digital converter (ADC) double width module with CAMAC back plane has been developed for nuclear physics experiments with a large number of detectors. This module has sixteen independent channels in plug-in daughter card mother board mode

  17. Whole-lesion ADC histogram and texture analysis in predicting recurrence of cervical cancer treated with CCRT.

    Science.gov (United States)

    Meng, Jie; Zhu, Lijing; Zhu, Li; Xie, Li; Wang, Huanhuan; Liu, Song; Yan, Jing; Liu, Baorui; Guan, Yue; He, Jian; Ge, Yun; Zhou, Zhengyang; Yang, Xiaofeng

    2017-11-03

    To explore the value of whole-lesion apparent diffusion coefficient (ADC) histogram and texture analysis in predicting tumor recurrence of advanced cervical cancer treated with concurrent chemo-radiotherapy (CCRT). 36 women with pathologically confirmed advanced cervical squamous carcinomas were enrolled in this prospective study. 3.0 T pelvic MR examinations including diffusion weighted imaging (b = 0, 800 s/mm 2 ) were performed before CCRT (pre-CCRT) and at the end of 2nd week of CCRT (mid-CCRT). ADC histogram and texture features were derived from the whole volume of cervical cancers. With a mean follow-up of 25 months (range, 11 ∼ 43), 10/36 (27.8%) patients ended with recurrence. Pre-CCRT 75th, 90th, correlation, autocorrelation and mid-CCRT ADC mean , 10th, 25th, 50th, 75th, 90th, autocorrelation can effectively differentiate the recurrence from nonrecurrence group with area under the curve ranging from 0.742 to 0.850 (P values range, 0.001 ∼ 0.038). Pre- and mid-treatment whole-lesion ADC histogram and texture analysis hold great potential in predicting tumor recurrence of advanced cervical cancer treated with CCRT.

  18. A Novel Digital Background Calibration Technique for 16 bit SHA-less Multibit Pipelined ADC

    Directory of Open Access Journals (Sweden)

    Swina Narula

    2016-01-01

    Full Text Available In this paper, a high resolution of 16 bit and high speed of 125MS/s, multibit Pipelined ADC with digital background calibration is presented. In order to achieve low power, SHA-less front end is used with multibit stages. The first and second stages are used here as a 3.5 bit and the stages from third to seventh are of 2.5 bit and last stage is of 3-bit flash ADC. After bit alignment and truncation of total 19 bits, 16 bits are used as final digital output. To precise the remove linear gain error of the residue amplifier and capacitor mismatching error, a digital background calibration technique is used, which is a combination of signal dependent dithering (SDD and butterfly shuffler. To improve settling time of residue amplifier, a special circuit of voltage separation is used. With the proposed digital background calibration technique, the spurious-free dynamic range (SFDR has been improved to 97.74 dB @30 MHz and 88.9 dB @150 MHz, and the signal-to-noise and distortion ratio (SNDR has been improved to 79.77 dB @ 30 MHz, and 73.5 dB @ 150 MHz. The implementation of the Pipelined ADC has been completed with technology parameters of 0.18μm CMOS process with 1.8 V supply. Total power consumption is 300 mW by the proposed ADC.

  19. The correlation between biological activity and diffusion-weighted MR imaging and ADC value in cases with prostate cancer

    Directory of Open Access Journals (Sweden)

    Bedriye Koyuncu Sokmen

    2017-12-01

    Full Text Available Purpose: Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. Methods: A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1 (n = 20 (Stage T1c-T2a, PSA T3a, PSA > 20 ng/ml, Gleason Score > 7. Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. Results: ADC values of the cases in Group 3 were lower than those of the other groups (p 0.05. Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p < 0.001. Conclusion: In tumors with higher Gleason scores, lower ADC values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.

  20. Design Strategy for a Pipelined ADC Employing Digital Post-correction

    NARCIS (Netherlands)

    Harpe, P.J.A.; Zanikopoulos, A.; Hegt, J.A.; Roermund, van A.H.M.

    2004-01-01

    This paper describes how the usage of digital post-correction techniques in pipelined analog-to-digital converters (ADC's) can be exploited optimally during the design-phase of the converter. It is known that post-correction algorithms reduce the influence of several cir- cuit impairments on the

  1. SU-F-J-173: Online Replanning for Dose Painting Based On Changing ADC Map of Pancreas Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ates, O; Ahunbay, E; Erickson, B; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2016-06-15

    Purpose: The introduction of MR-guided radiation therapy (RT), e.g., MR-Linac, would allow dose painting to adapt spatial RT response revealed from MRI data during the RT delivery. The purpose of this study is to investigate the use of an online replanning method to adapt dose painting from the MRI Apparent Diffusion Coefficient (ADC) map acquired during the delivery of RT for pancreatic cancers. Methods: Original dose painting plans were created based on multi-parametric simulation MRI including T1, T2 and ADC, using a treatment planning system (MONACO, Elekta) equipped with an online replanning algorithm (WSO, warm start optimization). Multiple GTVs, identified based on various ADC levels were prescribed to different doses ranging from 50–70 Gy with simultaneous integrated boost in 28 fractions. The MRI acquired after RT were used to mimic weekly MRI, on which the changing GTVs, pancreatic head and other organs-at-risk (OAR) (duodenum, stomach, small bowel) were delineated. The adaptive plan was generated by applying WSO algorithm starting from the deformed original plan based on the weekly MRI using a deformable image registration (DIR) software (ADMIRE, Elekta). The online replanning method takes <10 min. including DIR, target delineation, WSO execution and final dose calculation. Standard IGRT repositioning and full-blown reoptimization plans were also generated to compare with the adaptive plans. Results: The online replanning method significantly improved the multiple target coverages and OAR sparing for pancreatic cancers. For example, for a case with two GTVs with prescriptions of 60 and 70 Gy in pancreatic head, V100-GTV70 (the volume covered by 100% of prescription dose for GTV with 70 Gy)/V100-GTV60/V100-CTV50/V45-duodenum were (95.1/22.2/69.5/85.7), (95.0/97.0/98.6/34.3), and (95.0/98.1/100.0/38.7) for the IGRT, adaptive and reoptimization plans, respectively. Conclusion: The introduced online adaptive replanning method can effectively account for

  2. A 10-bit 80-MS/s opamp-sharing pipelined ADC with a switch-embedded dual-input MDAC

    Energy Technology Data Exchange (ETDEWEB)

    Yin Rui; Zhang Wei; Tang Zhangwen [ASIC and System State Key Laboratory, Fudan University, Shanghai 201203 (China); Liao Youchun, E-mail: zwtang@fudan.edu.cn [Ratio Microelectronics Co., Ltd, Shanghai 200433 (China)

    2011-02-15

    A 10-bit 80-MS/s opamp-sharing pipelined ADC is implemented in a 0.18-{mu}m CMOS. An opamp-sharing MDAC with a switch-embedded dual-input opamp is proposed to eliminate the non-resetting and successive-stage crosstalk problems observed in the conventional opamp-sharing technique. The ADC achieves a peak SNDR of 60.1 dB (ENOB = 9.69 bits) and a peak SFDR of 76 dB, while maintaining more than 9.6 ENOB for the full Nyquist input bandwidth. The core area of the ADC is 1.1 mm{sup 2} and the chip consumes 28 mW with a 1.8 V power supply. (semiconductor integrated circuits)

  3. Comparative study of the sensitivity of ADC value and T2 relaxation time for early detection of Wallerian degeneration

    International Nuclear Information System (INIS)

    Zhang Fan; Lu Guangming; Zee Chishing

    2011-01-01

    Background and purpose: Wallerian degeneration (WD), the secondary degeneration of axons from cortical and subcortical injuries, is associated with poor neurological outcome. There is some quantitative MR imaging techniques used to estimate the biologic changes secondary to delayed neuronal and axonal losses. Our purpose is to assess the sensitivity of ADC value and T 2 relaxation time for early detection of WD. Methods: Ten male Sprague-Dawley rats were used to establish in vivo Wallerian degeneration model of CNS by ipsilateral motor-sensory cortex ablation. 5 days after cortex ablation, multiecho-T 2 relaxometry and multi-b value DWI were acquired by using a 7 T MR imaging scanner. ADC-map and T 2 -map were reconstructed by post-processing. ROIs are selected according to pathway of corticospinal tract from cortex, internal capsule, cerebral peduncle, pons, medulla oblongata to upper cervical spinal cord to measure ADC value and T 2 relaxation time of healthy side and affected side. The results were compared between the side with cortical ablation and the side without ablation. Results: Excluding ablated cortex, ADC values of the corticospinal tract were significantly increased (P 2 relaxation time was observed between the affected and healthy sides. Imaging findings were correlated with histological examinations. Conclusion: As shown in this animal experiment, ADC values could non-invasively demonstrate the secondary degeneration involving descending white matter tracts. ADC values are more sensitive indicators for detection of early WD than T 2 relaxation time.

  4. New read-out electronics for ICARUS-T600 liquid Argon TPC. Description, simulation and tests of the new front-end and ADC system arXiv

    CERN Document Server

    Bagby, L.; Bellini, V.; Bonesini, M.; Braggiotti, A.; Castellani, L.; Centro, S.; Cervi, T.; Cocco, A.G.; Fabris, F.; Falcone, A.; Farnese, C.; Fava, A.; Fichera, F.; Franciotti, D.; Galet, G.; Gibin, D.; Guglielmi, A.; Guida, R.; Ketchum, W.; Marchini, S.; Menegolli, A.; Meng, G.; Menon, G.; Montanari, C.; Nessi, M.; Nicoletto, M.; Pedrotta, R.; Picchi, P.; Pietropaolo, F.; Rampazzo, G.; Rappoldi, A.; Raselli, G.L.; Rossella, M.; Rubbia, C.; Scaramelli, A.; Sergiampietri, F.; Spanu, M.; Torti, M.; Tortorici, F.; Varanini, F.; Ventura, S.; Vignoli, C.; Zani, A.; Zatti, P.G.

    The ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included also a new design of the read-out electronics, in view of its operation in Fermilab on the Short Baseline Neutrino (SBN) beam from 2019. The new more compact electronics showed capability of handling more efficiently the signals also in the intermediate Induction 2 wire plane with a significant increase of signal to noise (S/N), allowing for charge measurement also in this view. The new front-end and the analog to digital conversion (ADC) system are presented together with the results of the tests on 50 liters liquid argon TPC performed at CERN with cosmic rays.

  5. Diagnostic value of diffusion weighted MRI and ADC in differential ...

    African Journals Online (AJOL)

    Ankara Oncology Training and Research Hospital, Department of Radiology, Ankara/Turkey. 2. ... created and ADC values were measured for 72 liver masses and normal liver tissue (control group). ... ing MR gradient strength and duration) (b=400-1000 .... (B) Fat suppressed T1 weighted image after IV contrast showing.

  6. Rad-Hard Sigma-Delta 3-channel ADC for Fluxgate Magnetometers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project aims to develop a multi-channel analog to digital converter (ADC) required for a fluxgate magnetometer (EPD) employed on NASA's planetary...

  7. Adjustable Nyquist-rate System for Single-Bit Sigma-Delta ADC with Alternative FIR Architecture

    Science.gov (United States)

    Frick, Vincent; Dadouche, Foudil; Berviller, Hervé

    2016-09-01

    This paper presents a new smart and compact system dedicated to control the output sampling frequency of an analogue-to-digital converters (ADC) based on single-bit sigma-delta (ΣΔ) modulator. This system dramatically improves the spectral analysis capabilities of power network analysers (power meters) by adjusting the ADC's sampling frequency to the input signal's fundamental frequency with a few parts per million accuracy. The trade-off between straightforwardness and performance that motivated the choice of the ADC's architecture are preliminary discussed. It particularly comes along with design considerations of an ultra-steep direct-form FIR that is optimised in terms of size and operating speed. Thanks to compact standard VHDL language description, the architecture of the proposed system is particularly suitable for application-specific integrated circuit (ASIC) implementation-oriented low-power and low-cost power meter applications. Field programmable gate array (FPGA) prototyping and experimental results validate the adjustable sampling frequency concept. They also show that the system can perform better in terms of implementation and power capabilities compared to dedicated IP resources.

  8. Timing and control requirements for a 32-channel AMU-ADC ASIC for the PHENIX detector

    International Nuclear Information System (INIS)

    Emery, M.S.; Ericson, M.N.; Britton, C.L. Jr.

    1998-01-01

    A custom CMOS Application Specific Integrated Circuit (ASIC) has been developed consisting of an analog memory unit (AMU) has been developed consisting of an analog memory unit (AMU) and analog to digital converter (ADC), both of which have been designed for applications in the PHENIX experiment. This IC consists of 32 pipes of analog memory with 64 cells per pipe. Each pipe also has its own ADC channel. Timing and control signal requirements for optimum performance are discussed in this paper

  9. A SAR-ADC using unit bridge capacitor and with calibration for the front-end electronics of PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wei [School of Computer Science and Engineering, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Wei, Tingcun, E-mail: weitc@nwpu.edu.cn [School of Computer Science and Engineering, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Li, Bo; Yang, Lifeng; Xue, Feifei [School of Computer Science and Engineering, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Hu, Yongcai [Institut Pluridisciplinaire Hubert CURIEN, Strasbourg (France)

    2016-05-11

    This paper presents a 12-bit 1 MS/s successive approximation register-analog to digital converter (SAR-ADC) for the 32-channel front-end electronics of CZT-based PET imaging system. To reduce the capacitance mismatch, instead of the fractional capacitor, the unit capacitor is used as the bridge capacitor in the split-capacitor digital to analog converter (DAC) circuit. In addition, in order to eliminate the periodical DNL errors of −1 LSB which often exists in the SAR-ADC using the charge-redistributed DAC, a calibration algorithm is proposed and verified by the experiments. The proposed 12-bit 1 MS/s SAR-ADC is designed and implemented using a 0.35 μm CMOS technology, it occupies only an active area of 986×956 μm{sup 2}. The measurement results show that, at the power supply of 3.3/5.0 V and the sampling rate of 1 MS/s, the ADC with calibration has a signal-to-noise-and-distortion ratio (SINAD) of 67.98 dB, the power dissipation of 5 mW, and a figure of merit (FOM) of 2.44 pJ/conv.-step. This ADC is with the features of high accuracy, low power and small layout area, it is especially suitable to the one-chip integration of the front-end readout electronics.

  10. A 100 MS/s 9 bit 0.43 mW SAR ADC with custom capacitor array

    Science.gov (United States)

    Jingjing, Wang; Zemin, Feng; Rongjin, Xu; Chixiao, Chen; Fan, Ye; Jun, Xu; Junyan, Ren

    2016-05-01

    A low power 9 bit 100 MS/s successive approximation register analog-to-digital converter (SAR ADC) with custom capacitor array is presented. A brand-new 3-D MOM unit capacitor is used as the basic capacitor cell of this capacitor array. The unit capacitor has a capacitance of 1 fF. Besides, the advanced capacitor array structure and switch mode decrease the power consumption a lot. To verify the effectiveness of this low power design, the 9 bit 100 MS/s SAR ADC is implemented in TSMC IP9M 65 nm LP CMOS technology. The measurement results demonstrate that this design achieves an effective number of bits (ENOB) of 7.4 bit, a signal-to-noise plus distortion ratio (SNDR) of 46.40 dB and a spurious-free dynamic range (SFDR) of 62.31 dB at 100 MS/s with 1 MHz input. The SAR ADC core occupies an area of 0.030 mm2 and consumes 0.43 mW under a supply voltage of 1.2 V. The figure of merit (FOM) of the SAR ADC achieves 23.75 fJ/conv. Project supported by the National High-Tech Research and Development Program of China (No. 2013AA014101).

  11. Multi-model Analysis of Diffusion-weighted Imaging of Normal Testes at 3.0 T: Preliminary Findings.

    Science.gov (United States)

    Min, Xiangde; Feng, Zhaoyan; Wang, Liang; Cai, Jie; Li, Basen; Ke, Zan; Zhang, Peipei; You, Huijuan; Yan, Xu

    2018-04-01

    This study aimed to establish diffusion quantitative parameters (apparent diffusion coefficient [ADC], DDC, α, D app , and K app ) in normal testes at 3.0 T. Sixty-four healthy volunteers in two age groups (A: 10-39 years; B: ≥ 40 years) underwent diffusion-weighted imaging scanning at 3.0 T. ADC 1000 , ADC 2000 , ADC 3000 , DDC, α, D app , and K app were calculated using the mono-exponential, stretched-exponential, and kurtosis models. The correlations between parameters and the age were analyzed. The parameters were compared between the age groups and between the right and the left testes. The average ADC 1000 , ADC 2000 , ADC 3000 , DDC, α, D app , and K app values did not significantly differ between the right and the left testes (P > .05 for all). The following significant correlations were found: positive correlations between age and testicular ADC 1000 , ADC 2000 , ADC 3000 , DDC, and D app (r = 0.516, 0.518, 0.518, 0.521, and 0.516, respectively; P < .01 for all) and negative correlations between age and testicular α and K app (r = -0.363, -0.427, respectively; P < .01 for both). Compared to group B, in group A, ADC 1000 , ADC 2000 , ADC 3000 , DDC, and D app were significantly lower (P < .05 for all), but α and K app were significantly higher (P < .05 for both). Our study demonstrated the applicability of the testicular mono-exponential, stretched-exponential, and kurtosis models. Our results can help establish a baseline for the normal testicular parameters in these diffusion models. The contralateral normal testis can serve as a suitable reference for evaluating the abnormalities of the other side. The effect of age on these parameters requires further attention. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. A new method for reducing DNL in nuclear ADCs using an interpolation technique

    International Nuclear Information System (INIS)

    Vaidya, P.P.; Gopalakrishnan, K.R.; Pethe, V.A.; Anjaneyulu, T.

    1986-01-01

    The paper describes a new method for reducing the DNL associated with nuclear ADCs. The method named the ''interpolation technique'' is utilized to derive the quantisation steps corresponding to the last n bits of the digital code by dividing quantisation steps due to higher significant bits of the DAC, using a chain of resistors. Using comparators, these quantisation steps are compared with the analog voltage to be digitized, which is applied as a voltage shift at both ends of this chain. The output states of the comparators define the n bit code. The errors due to offset voltages and bias currents of the comparators are statistically neutralized by changing the polarity of quantisation steps as well as the polarity of analog voltage (corresponding to last n bits) for alternate A/D conversion. The effect of averaging on the channel profile can be minimized. A 12 bit ADC was constructured using this technique which gives DNL of less than +-1% over most of the channels for conversion time of nearly 4.5 μs. Gatti's sliding scale technique can be implemented for further reduction of DNL. The interpolation technique has a promising potential of improving the resolution of existing 12 bit ADCs to 16 bit, without degrading the percentage DNL significantly. (orig.)

  13. Dynamic changes in water ADC, energy metabolism, extracellular space volume and tortuosity in neonatal rat brain during irreversible ischemia

    NARCIS (Netherlands)

    Toorn, van der A.; Syková, E.; Dijkhuizen, R.M.; Voríšek, I.; Vargová, L.; Skobisová, E.; Lookeren Campagne, van M.; Reese, T.; Nicolaij, K.

    1996-01-01

    To obtain a better understanding of the mechanisms underlying early changes in the brain water apparent diffusion coefficient (ADC) observed in cerebral ischemia, dynamic changes in the ADC of water and in the energy status were measured at postnatal day 8 or 9 in neonatal rat brains after cardiac

  14. Flash-ADCs test, optimization of the detector design and development of a new concept of spatial reconstruction in the double chooz neutrino oscillation experiment

    International Nuclear Information System (INIS)

    Akiri, T.

    2010-09-01

    Double Chooz (DC) is a reactor neutrino oscillation experiment whose purpose is the measurement of the last unknown mixing angle θ 13 . It inherits from the past Chooz experiment which was limited by the statistical and systematic errors at the same extent of about 2.8%. To lower the statistical error, the DC detector target mass has been increased and a longer exposure is foreseen while the lowering of the systematic error is ensured by the use of two identical detectors. One will be located in the vicinity of the reactor cores to monitor the flux and spectrum of the ν-bar e emitted whereas the other one will be located where the effect of the oscillation is expected to be maximal. They are respectively so-called 'near' and 'far' detectors. The expected errors are 0.5% (stat.) and 0.6% (syst.) for a measurement down to sin 2 (2*θ 13 ) = 0.05 (θ 13 6.5 degrees) at three standard deviations after three years of data taking. The far detector is expected for November 2010 while the near detector will be operational in mid-2012. This thesis presents first a hardware work consisting in testing the Flash-ADCs that are the core of the main acquisition system of the experiment. Subsequently, it presents analyses performed on Monte Carlo simulations towards the optimization of the detector design. This work was composed of analyses to choose some detector components with the appropriate natural radioactivity contamination, analyses for the best achievable energy resolution and the most stable and robust way of triggering. The work on the optimization of the detector together with the acquired knowledge on the Flash-ADCs led us to envisage the possibility of a new spatial reconstruction based on the time of flight. All these contributions to the experiment are described in details throughout this manuscript. (author)

  15. Microprocessor controlled dual parameter ADC system with a CAMAC interface

    Energy Technology Data Exchange (ETDEWEB)

    Perry, D G; Nickell, Jr, J D [Los Alamos Scientific Lab., NM (USA)

    1978-09-01

    Presented here is the design of a dual parameter ADC system which is controlled by a microprocessor and also interfaced to CAMAC. The system was designed to be mobile in that it may work wherever there is a CAMAC crate. In such cases where the CAMAC system is inoperative, the system may operate in a stand-alone mode.

  16. Evaluation of HIV testing recommendations in specialty guidelines for the management of HIV indicator conditions

    DEFF Research Database (Denmark)

    Lord, E; Stockdale, A J; Malek, R

    2017-01-01

    OBJECTIVES: European guidelines recommend HIV testing for individuals presenting with indicator conditions (ICs) including AIDS-defining conditions (ADCs). The extent to which non-HIV specialty guidelines recommend HIV testing in ICs and ADCs is unknown. Our aim was to pilot a methodology in the UK...... are piloting methods to engage with guideline development groups to ensure that patients diagnosed with ICs/ADCs are tested for HIV. We then plan to apply our methodology in other European settings as part of the Optimising Testing and Linkage to Care for HIV across Europe (OptTEST) project....... to review specialty guidelines and ascertain if HIV was discussed and testing recommended. METHODS: UK and European HIV testing guidelines were reviewed to produce a list of 25 ADCs and 49 ICs. UK guidelines for these conditions were identified from searches of the websites of specialist societies...

  17. A low power cyclic ADC design for a wireless monitoring system for orthopedic implants

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yi; Li Fule; Chen Hong; Zhang Chun; Wang Zhihua, E-mail: chenyi02@mails.tsinghua.edu.c [Tsinghua National Laboratory for Information Science and Technology, Institute of Microelectronics, Tsinghua University, Beijing 100084 (China)

    2009-08-15

    This paper presents a low power cyclic analog-to-digital convertor (ADC) design for a wireless monitoring system for orthopedic implants. A two-stage cyclic structure including a single to differential converter, two multiplying DAC functional blocks (MDACs) and some comparators is adopted, which brings moderate speed and moderate resolution with low power consumption. The MDAC is implemented with the common switched capacitor method. The 1.5-bit stage greatly simplifies the design of the comparator. The operational amplifier is carefully optimized both in schematic and layout for low power and offset. The prototype chip has been fabricated in a United Microelectronics Corporation (UMC) 0.18-{mu}m 1P6M CMOS process. The core of the ADC occupies only 0.12 mm{sup 2}. With a 304.7-Hz input and 4-kHz sampling rate, the measured peak SNDR and SFDR are 47.1 dB and 57.8 dBc respectively and its DNL and INL are 0.27 LSB and 0.3 LSB, respectively. The power consumption of the ADC is only 12.5 {mu}W in normal working mode and less than 150 nW in sleep mode. (semiconductor integrated circuits)

  18. Automated Test Case Generation

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    I would like to present the concept of automated test case generation. I work on it as part of my PhD and I think it would be interesting also for other people. It is also the topic of a workshop paper that I am introducing in Paris. (abstract below) Please note that the talk itself would be more general and not about the specifics of my PhD, but about the broad field of Automated Test Case Generation. I would introduce the main approaches (combinatorial testing, symbolic execution, adaptive random testing) and their advantages and problems. (oracle problem, combinatorial explosion, ...) Abstract of the paper: Over the last decade code-based test case generation techniques such as combinatorial testing or dynamic symbolic execution have seen growing research popularity. Most algorithms and tool implementations are based on finding assignments for input parameter values in order to maximise the execution branch coverage. Only few of them consider dependencies from outside the Code Under Test’s scope such...

  19. A Low Power Rad-Hard ADC for the KID Readout Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposal aims to develop a radiation hardened analog-to-digital converter (ADC) required for the Kinetic Inductance Detector (KID) readout electronics. KIDs are...

  20. Comparative study of the sensitivity of ADC value and T{sub 2} relaxation time for early detection of Wallerian degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Fan [Department of Radiology, Nanjing Jinling Hospital, Clinical School of Medical College of Nanjing University, Nanjing 210002 (China); Lu Guangming, E-mail: cjr.luguangming@vip.163.com [Department of Radiology, Nanjing Jinling Hospital, Clinical School of Medical College of Nanjing University, Nanjing 210002 (China); Zee Chishing, E-mail: chishing@usc.edu [Department of Radiology, USC Keck School of Medicine (United States)

    2011-07-15

    Background and purpose: Wallerian degeneration (WD), the secondary degeneration of axons from cortical and subcortical injuries, is associated with poor neurological outcome. There is some quantitative MR imaging techniques used to estimate the biologic changes secondary to delayed neuronal and axonal losses. Our purpose is to assess the sensitivity of ADC value and T{sub 2} relaxation time for early detection of WD. Methods: Ten male Sprague-Dawley rats were used to establish in vivo Wallerian degeneration model of CNS by ipsilateral motor-sensory cortex ablation. 5 days after cortex ablation, multiecho-T{sub 2} relaxometry and multi-b value DWI were acquired by using a 7 T MR imaging scanner. ADC-map and T{sub 2}-map were reconstructed by post-processing. ROIs are selected according to pathway of corticospinal tract from cortex, internal capsule, cerebral peduncle, pons, medulla oblongata to upper cervical spinal cord to measure ADC value and T{sub 2} relaxation time of healthy side and affected side. The results were compared between the side with cortical ablation and the side without ablation. Results: Excluding ablated cortex, ADC values of the corticospinal tract were significantly increased (P < 0.05) in affected side compared to the unaffected, healthy side; no difference in T{sub 2} relaxation time was observed between the affected and healthy sides. Imaging findings were correlated with histological examinations. Conclusion: As shown in this animal experiment, ADC values could non-invasively demonstrate the secondary degeneration involving descending white matter tracts. ADC values are more sensitive indicators for detection of early WD than T{sub 2} relaxation time.

  1. Application of Σ-ΔADC in fluorescence measurement

    International Nuclear Information System (INIS)

    Hao Yan; Chen Ziyu; Shen Ji

    2011-01-01

    It introduces the measurement system of fluorescence intensity, the Σ-ΔADC used as its core components. The system consisted of ADS1255, microcontrollers LPC2368 devices, etc. LPC2368 is used as the control, data process and communication interface. Diagram of the system is given. The linear response experiments, frequency response experiments, measurement accuracy experiments and long-time stability experiments were carried out. Experiments show that the system reaches a good linear response, and the measurement accuracy reaches up to 0.01%. (authors)

  2. Very High-Performance Advanced Filter Bank Analog-to-Digital Converter (AFB ADC) Project

    National Research Council Canada - National Science Library

    Velazquez, Scott

    1999-01-01

    ... of the art by using a parallel array of individual commercial off the shelf converters. The significant performance improvements afforded by the Advanced Filter Bank Analog to Digital Converter (AFB ADC...

  3. Diffusion-weighted magnetic resonance imaging for the initial characterization of non-fatty soft tissue tumors: correlation between T2 signal intensity and ADC values

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto [Service d' Imagerie Guilloz, CHU Nancy, Nancy (France); Universite de Lorraine, IADI, UMR S 947, Vandoeuvre-les-Nancy (France); Gay, Frederique; Blum, Alain [Service d' Imagerie Guilloz, CHU Nancy, Nancy (France); Chen, Bailiang; Felblinger, Jacques [Universite de Lorraine, IADI, UMR S 947, Vandoeuvre-les-Nancy (France); Zins, Marie [University Versailles St-Quentin, Versailles (France); Inserm, Centre for research in Epidemiology and Population Health (CESP), U1018, Villejuif (France); Sirveaux, Francois [Centre Chirurgical Emile Galle, Service de Chirurgie Traumatologique et Orthopedique, Nancy (France)

    2016-02-15

    To evaluate the performance of quantitative diffusion-weighted imaging (DWI) correlated with T2 signal in differentiating non-fatty benign from malignant tumors. A total of 76 patients with a histologically confirmed non-fatty soft tissue tumors (46 benign and 30 malignant) were prospectively included in this ethics committee approved study. All patients signed an informed consent and underwent MRI with DWI with two b values (0 and 600). ADC values from the solid components of these tumors were obtained and were correlated with the lesion's signal intensity on T2-weighted fat-saturated sequences. ADC values were obtained from adjacent normal muscle to allow calculation of tumor/muscle ADC ratios. There were 58 hyperintense and 18 iso or hypointense lesions. All hypointense lesions were benign. The mean ADC values for benign and malignant tumors were 1.47 ± 0.54 x 10{sup -3} and 1.17 ± 0.38 x 10{sup -3} mm{sup 2}/s respectively (p < 0.005). The mean ADC ratio in benign iso or hypointense tumors was significantly lower than that of hyperintense ones (0.76 ± 0.21 versus 1.58 ± 0.82 - p < 0.0001). An ADC ratio lower than 0.915 was highly specific for malignancy (96.4 %), whereas an ADC ratio higher than 1.32 was highly sensitive for benign lesions (90 %). ADC analysis can be useful in the initial characterization of T2 hyperintense non-fatty soft tissue masses, although this technique alone is not likely to change patient management. (orig.)

  4. Design and characterization of a 12-bit 10MS/s 10mW pipelined SAR ADC for CZT-based hard X-ray imager

    Science.gov (United States)

    Xue, F.; Gao, W.; Duan, Y.; Zheng, R.; Hu, Y.

    2018-02-01

    This paper presents a 12-bit pipelined successive approximation register (SAR) ADC for CZT-based hard X-ray Imager. The proposed ADC is comprised of a first-stage 6-bit SAR-based Multiplying Digital Analog Converter (MDAC) and a second-stage 8-bit SAR ADC. A novel MDAC architecture using Vcm-based Switching method is employed to maximize the energy efficiency and improve the linearity of the ADC. Moreover, the unit-capacitor array instead of the binary-weighted capacitor array is adopted to improve the conversion speed and linearity of the ADC in the first-stage MDAC. In addition, a new layout design method for the binary-weighted capacitor array is proposed to reduce the capacitor mismatches and make the routing become easier and less-time-consuming. Finally, several radiation-hardened-by-design technologies are adopted in the layout design against space radiation effects. The prototype chip was fabricated in 0.18 μm mixed-signal 1.8V/3.3V process and operated at 1.8 V supply. The chip occupies a core area of only 0.58 mm2. The proposed pipelined SAR ADC achieves a peak signal-to-noise-and-distortion ratio (SNDR) of 66.7 dB and a peak spurious-free dynamic range (SFDR) of 78.6 dB at 10 MS/s sampling rate and consumes 10 mW. The figure of merit (FOM) of the proposed ADC is 0.56 pJ/conversion-step.

  5. Comparison of ADC map with trace map in the normal and infarct areas of the brains of stroke patients

    International Nuclear Information System (INIS)

    Kim, Seung Hyung; Yoon, Pyeong Ho; Jeong, Eun Kee; Oh, Young Taick; Kim, Dong Ik

    1999-01-01

    To compare ADC mapping with trace mapping in normal and infarct areas of the brains of stroke patients. Eighteen patients diagnosed on the basis of clinical and brain MRI examinations as suffering from brain infarction were included in this study (hyperacute-1, acute-4, subacute-12, chronic-1). Diffusion weighted images of three orthogonal directions of a patient's brain were obtained by means of a single shot EPI pulse sequence, using a diffusion gradient with four serial b-factors. Three ADC maps were then reconstructed by post-image processing and were summed pixel by pixel to yield a trace map. ROIs were selected in the normal areas of white matter, gray matter and CSF of one hemisphere, and other ROIs of the same size were selected at the same site of the contralateral hemisphere. ADC and trace values were measured and right/left ratios of ADC and trace values were calculated. Using these values, we then compared the ADC map with the trace map, and compared the degree of anisotropic diffusion between white matter, gray matter and CSF. Except for three, whose infarct lesions were small and lay over white and gray matter, patients were divided into two groups. Those with infarct in the white matter (n=10) were assigned to one group, and those with infarct in the gray matter (n=5) to the other. ROIs were selected in the infarct area and other ROIs of the same size were selected at the same site of the contralateral hemisphere. ADC and trace values were measured and infarct/contralateral ratios were calculated. We then compared ADC ratio with trace ratio in white matter and gray matter infarct. In normal white matter, the Dxx ratio was 0.980±0.098, the Dyy ratio 1.019±0.086, the Dzz ratio 0.999±0.111, and the trace ratio 0.995±0.031. In normal gray matter, the Dxx ratio was 1.001±0.058, the Dyy ratio 0.996±0.063, Dzz ratio 1.005±0.070, and the trace ratio 1.001±0.028. In CSF, the Dxx ratio was 1.002±0.064, the Dyy ratio 1.023±0.055, the Dzz ratio 0.999

  6. The correlation between biological activity and diffusion-weighted MR imaging and ADC value in cases with prostate cancer.

    Science.gov (United States)

    Sokmen, Bedriye Koyuncu; Sokmen, Dogukan; Ucar, Nese; Ozkurt, Huseyin; Simsek, Abdulmuttalip

    2017-12-31

    Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR) images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC) values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1) (n = 20) (Stage T1c-T2a, PSA T3a, PSA > 20 ng/ml, Gleason Score > 7). Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. ADC values of the cases in Group 3 were lower than those of the other groups (p values of the areas without malignancy did not differ significantly between groups (p > 0.05). Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.

  7. Practical testing of diesel generators

    International Nuclear Information System (INIS)

    Angle, C.W.; Meyer, S.P.

    1985-01-01

    The testing of diesel generators is a very important facet of the safe operation of nuclear power plants. Improper testing can lead to increased failures and unavailability of the engines resulting in a reduced safety factor for a nuclear plant. For a testing program to be successful it must be well planned and effectively implemented. In addition, inspections and maintenance activities also impact diesel generator availability. This paper describes elements of a suggested diesel generator testing program as well as some of the pitfalls to be avoided

  8. Charge-sharing SAR ADCs for low-voltage low-power applications

    CERN Document Server

    Rabuske, Taimur

    2017-01-01

    This book introduces readers to the potential of charge-sharing (CS) successive approximation register (SAR) analog-to-digital converters (ADCs), while providing extensive analysis of the factors that limit the performance of the CS topology. The authors present guidelines and useful techniques for mitigating the limitations of the architecture, while focusing on the implementation under restricted power budgets and voltage supplies.

  9. The changes of 18F-FDG uptake and ADC value of the normal endometrium during the menstrual cycle

    International Nuclear Information System (INIS)

    Seko, Ayumi; Kanasaki, Shuzou; Kitahara, Sawako; Murata, Kiyoshi; Tatsumi, Mitsuaki; Hayashida, Kohei; Sakashita, Yoko; Hamanaka, Yasuyo

    2007-01-01

    We evaluated the normal endometrium of reproductive age using positron emission tomography (PET)/CT and Diffusion-weighted MR imaging. 18 F-fluorodeoxyglucose (FDG) uptake and apparent diffusion coefficient (ADC) value were classified according to the menstrual cycle. On PET/CT, FDG uptake was significant high at the menstrual and ovulatory phase. On diffusion-weighted imaging (DWI), ADC value was significant low at the menstrual phase. (author)

  10. Chemical and biological studies of Lobelia flaccida (C. Presl) A.DC ...

    African Journals Online (AJOL)

    Chemical and biological studies of Lobelia flaccida (C. Presl) A.DC leaf: a medicinal plant used by traditional healers in Eastern Cape, South Africa. ... (85 mg/kg, intraperitoneally)-induced convulsion model in mice, normal saline and diazepam (1 mg/kg, i.p.) served as negative and positive control groups respectively.

  11. A rule-based software test data generator

    Science.gov (United States)

    Deason, William H.; Brown, David B.; Chang, Kai-Hsiung; Cross, James H., II

    1991-01-01

    Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.

  12. VHDL implementation on histogram with ADC CAMAC module

    International Nuclear Information System (INIS)

    Ruby Santhi, R.; Satyanarayana, V.V.V.; Ajith Kumar, B.P.

    2007-01-01

    Modern nuclear spectroscopy systems the data acquisition and analysis in experimental science have been undergoing major changes because of faster speed and higher resolution. The CAMAC module which is described here is FPGA based 8K x 24 bit Histogram Memory integrated with ADC on a single board has been designed and fabricated. This module accepts input from Spectroscopy Amplifier for Pulse Height Analysis and offers all features single spectra for a few selected parameters. These on line histograms are to monitor the progress of the experiments during on line experiments

  13. Diffusion weighted imaging of liver lesions suspect for metastases: Apparent diffusion coefficient (ADC) values and lesion contrast are independent from Gd-EOB-DTPA administration

    International Nuclear Information System (INIS)

    Benndorf, Matthias; Schelhorn, Juliane; Dietzel, Matthias; Kaiser, Werner A.; Baltzer, Pascal A.T.

    2012-01-01

    Purpose: Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) enhanced liver MRI is widely used for detection and differentiation of focal liver lesions. Diffusion weighted imaging (DWI) including apparent diffusion coefficient (ADC) measurements is increasingly utilised as a fast and, with limitations, quantitative method for liver lesion detection and characterisation. Herein we investigate whether the administration of Gd-EOB-DTPA affects DWI. Materials and methods: 31 consecutive patients referred to standardised liver MRI (1.5 T, Gd-EOB-DTPA, 0.025 mmol/kg) were retrospectively reviewed. All underwent a breathhold DWI sequence before and after contrast agent administration (EPI-DWI, TR/TE (effective): 2100/62 ms, b-values: 0 and 800 s/mm 2 ). Patients with previously treated liver lesions were excluded. Signal intensity of lesion, parenchyma and noise on DWI images as well as the ADC value were measured after identification by two observers in consensus using manually placed regions of interest. The reference standard was imaging follow-up determined separately by two radiologists. Data analysis included signal-to-noise (SNR) ratio and contrast-to-noise ratio (CNR) calculations, comparisons were drawn by employing multiple Bonferroni corrected Wilcoxon signed-rank tests. Results: 50 malignant and 39 benign lesions were identified. Neither SNR, CNR nor ADC values showed significant differences between pre- and postcontrast DWI. Both pre- and postcontrast ADC values differed significantly between benign and malignant lesions (P < 0.001). Conclusion: We did not identify a significant influence of Gd-EOB-DTPA on DWI of liver lesions. This allows for individual tailoring of imaging protocols according to clinical needs.

  14. High-Speed, Low-Power ADC for Digital Beam Forming (DBF) Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop Group will design a high-speed, low-power silicon germanium (SiGe)-based, analog-to-digital converter (ADC) to be a key element for digital beam forming...

  15. An offset cancellation technique in a switched-capacitor comparator for SAR ADCs

    International Nuclear Information System (INIS)

    Tong Xingyuan; Zhu Zhangming; Yang Yintang

    2012-01-01

    An offset cancellation technique for a SAR (successive approximation register) ADC switched-capacitor comparator is described. The comparator is designed with a pre-amplifying and regenerative latching structure and realized in 0.18 μm CMOS. With the first stage preamplifier offset cancellation and low offset regenerative latching approach, the equivalent offset of the comparator is reduced to < 0.55 mV. By using the pre-amplifying and regenerative latching comparison mode the comparator exhibits low power dissipation. Under a 1.8 V power supply, with a 200 kS/s ADC sampling rate and 3 MHz clock frequency, a 13-bit comparison resolution is reached and less than 0.09 mW power dissipation is consumed. The superiority of this comparator is discussed and proved by the post-simulation and application to a 10 bit 200 kS/s touch screen SAR A/D converter. (semiconductor integrated circuits)

  16. High-Speed, Low-Power ADC for Digital Beam Forming (DBF) Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase 1, Ridgetop Group designed a high-speed, yet low-power silicon germanium (SiGe)-based, analog-to-digital converter (ADC) to be a key element for digital...

  17. Diffusion tensor imaging of the median nerve at 3.0 T using different MR scanners: Agreement of FA and ADC measurements

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Nanz, Daniel; Bussmann, Lorenz; Chhabra, Avneesh; Fischer, Michael A.; Hodler, Jürg; Pfirrmann, Christian W.A.; Andreisek, Gustav

    2013-01-01

    Objective: To assess the agreement of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of the median nerve on 3.0 T MR scanners from different vendors. Materials and methods: IRB approved study including 16 healthy volunteers (9 women; mean age 30.6 ± 5.3 years). Diffusion tensor imaging (DTI) of the dominant wrist was performed on three 3.0 T MR scanners (GE, Siemens, Philips) using similar imaging protocols and vendor-proprietary hard- and software. Intra-, inter-reader and inter-vendor agreements were assessed. Results: ICCs for intra-/inter-reader agreements ranged from 0.843–0.970/0.846–0.956 for FA, and 0.840–0.940/0.726–0.929 for ADC, respectively. ANOVA analysis identified significant differences for FA/ADC measurements among vendors (p −3 mm 2 /s (SD ± 0.134 × 10 −3 ) for ADC. A significant negative measurement bias was found for FA values from the GE scanner (−0.05 and −0.07) and for ADC values from the Siemens scanner (−0.053 and −0.063 × 10 −3 mm 2 /s) as compared to the remainder vendors Conclusion: FA and ADC values of the median nerve obtained on different 3.0 T MR scanners differ significantly, but are in comparison to the standard deviation of absolute values small enough to not have an impact on larger group studies or when substantial diffusion changes can be expected. However, caution is warranted in an individual patient when interpreting diffusion values from different scanner acquisitions

  18. SiGe 130 nm-based Rad-Hard ADC for the JEO Mission, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop will demonstrate the feasibility of developing a radiation-hardened analog-to-digital converter (ADC) suitable for the Jupiter Europa Orbiter mission. This...

  19. Fast Imaging Detector Readout Circuits with In-Pixel ADCs for Fourier Transform Imaging Spectrometers

    Science.gov (United States)

    Rider, D.; Blavier, J-F.; Cunningham, T.; Hancock, B.; Key, R.; Pannell, Z.; Sander, S.; Seshadri, S.; Sun, C.; Wrigley, C.

    2011-01-01

    Focal plane arrays (FPAs) with high frame rates and many pixels benefit several upcoming Earth science missions including GEO-CAPE, GACM, and ACE by enabling broader spatial coverage and higher spectral resolution. FPAs for the PanFTS, a high spatial resolution Fourier transform spectrometer and a candidate instrument for the GEO-CAPE mission are the focus of the developments reported here, but this FPA technology has the potential to enable a variety of future measurements and instruments. The ESTO ACT Program funded the developed of a fast readout integrated circuit (ROIC) based on an innovative in-pixel analog-to-digital converter (ADC). The 128 X 128 pixel ROIC features 60 ?m pixels, a 14-bit ADC in each pixel and operates at a continuous frame rate of 14 kHz consuming only 1.1 W of power. The ROIC outputs digitized data completely eliminating the bulky, power consuming signal chains needed by conventional FPAs. The 128 X 128 pixel ROIC has been fabricated in CMOS and tested at the Jet Propulsion Laboratory. The current version is designed to be hybridized with PIN photodiode arrays via indium bump bonding for light detection in the visible and ultraviolet spectral regions. However, the ROIC design incorporates a small photodiode in each cell to permit detailed characterization of the ROICperformance without the need for hybridization. We will describe the essential features of the ROIC design and present results of ROIC performance measurements.

  20. Circuit and method for comparator offset error detection and correction in ADC

    NARCIS (Netherlands)

    2017-01-01

    PROBLEM TO BE SOLVED: To provide a method for calibrating an analog-to-digital converter (ADC).SOLUTION: The method comprises: sampling an input voltage signal; comparing the sampled input voltage signal with an output signal of a feedback digital-to-analog converter (DAC) 40; determining in a

  1. ADC3 YANG DIBUAT DENGAN PELEBURAN ULANG ALUMINIUM BEKAS SEBAGAI BAHAN PROPELER KAPAL KAYU

    Directory of Open Access Journals (Sweden)

    Suyanto Suyanto

    2016-11-01

    Full Text Available Saat ini pembuatan propeler aluminium pada industri kecil banyak memanfaatkan bahan dasar aluminium bekas. Namun produk yang dihasilkan belum memenuhi spesifikasi standar material. Penelitian dilakukan dengan menggunakan bahan dasar aluminium siku bekas dan aluminium kampas bekas. Variasi penambahan TiB sebagai grain refiner dilakukan pada saat peleburan. Perhitungan dengan simulasi Excel dilakukan untuk memperkirakan komposisi hasil pengecoran yang sesuai. Pengecoran ulang menghasilkan produk dengan tingkat porositas 3,3 % sampai 5,9 %. Penggunaan cetakan pasir ikut berperan dalam timbulnya porositas. Penambahan TiB sebanyak 0,5% ke ADC3 berpengaruh pada penurunan ukuran butir hingga 50%, peningkatan kekerasan hingga 23%, peningkatan kekuatan tarik hingga 11%, serta penurunan keuletan hingga 20%. Kata kunci: ADC3, pengecoran ulang aluminium, propeler.

  2. The longitudinal effect of ejaculation on seminal vesicle fluid volume and whole-prostate ADC as measured on prostate MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Tristan; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Tanner, James; Gill, Andrew B.; Slough, Rhys A. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Wason, James [University of Cambridge, MRC Biostatistics Unit, Cambridge (United Kingdom)

    2017-12-15

    To prospectively investigate the longitudinal effect of ejaculatory abstinence on MRI-measured seminal vesicle (SV) volume and whole-prostate ADC over consecutive days. 15 healthy male volunteers (mean 35.9 years, range 27-53) underwent 3-T MRI at baseline and 1, 2 and 3 days post-ejaculation. Prostate and SV volumes were derived by volume segmentation and whole-gland apparent diffusion coefficient (ADC) values calculated. A mixed-effects linear regression compared ADC values and prostate/seminal vesicle volumes in each volunteer between studies in a pairwise manner. All subjects completed the four MRIs. Mean prostate volume was 22.45 cm{sup 3} (range 13.04-31.21 cm{sup 3}), with no change between the four studies (p = 0.89-0.99). 13/15 subjects showed SV volume reduction from baseline to day 1, with group-mean decreasing from 6.45 to 4.80 cm{sup 3} (-25.6%, p < 0.001), and a significant reduction from baseline to day 2 (-18.1%, p = 0.002). There was a significant volume increase from both day 1 (+21.3%, p = 0.006) and day 2 (+10.2%, p = 0.022) to day 3 post-ejaculation. There was a significant reduction in ADC from 1.105 at baseline to 1.056 x 10{sup -3} mm{sup 2}/s at day 1 (mean -4.3%, p = 0.009). The longitudinal effect of ejaculation on SV volume was demonstrated. Significant reductions in SV volume and whole-gland ADC were observed post-ejaculation, supporting a 3-day period of abstinence before prostate MRI. (orig.)

  3. Rule-based Test Generation with Mind Maps

    Directory of Open Access Journals (Sweden)

    Dimitry Polivaev

    2012-02-01

    Full Text Available This paper introduces basic concepts of rule based test generation with mind maps, and reports experiences learned from industrial application of this technique in the domain of smart card testing by Giesecke & Devrient GmbH over the last years. It describes the formalization of test selection criteria used by our test generator, our test generation architecture and test generation framework.

  4. DWI in breast MRI: Role of ADC value to determine diagnosis between recurrent tumor and surgical scar in operated patients

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, Pierluigi, E-mail: pierluigi.rinaldi@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Giuliani, Michela, E-mail: micgiuli@yahoo.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Belli, Paolo, E-mail: pbelli@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Costantini, Melania, E-mail: mcostantini@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Romani, Maurizio, E-mail: mromani@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Distefano, Daniela, E-mail: daniela_distefano@hotmail.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Bufi, Enida, E-mail: reagandus@alice.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Mule, Antonino, E-mail: amule@rm.unicatt.i [Division of Pathology and Histology, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Magno, Stefano, E-mail: smagno@rm.unicatt.i [Department of Surgery, Breast Unit, Catholic University Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Masetti, Riccardo, E-mail: riccardo.masetti@rm.unicatt.i [Department of Surgery, Breast Unit, Catholic University Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Bonomo, Lorenzo, E-mail: lbonomo@rm.unicatt.i [Dept. of Bio-Imaging and Radiological Sciences, Catholic Univ. - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy)

    2010-08-15

    Introduction: Purpose of our study is to evaluate the role of the apparent diffusion coefficient (ADC) in the diagnosis of recurrent tumor on the scar in patients operated for breast cancer. Assess, therefore, the weight of diagnostic diffusion echo-planar sequence, in association with the morphological and dynamic sequences in the diagnosis of tumor recurrence versus surgical scar. Materials and methods: From September 2007 to March 2009, 72 patients operated for breast cancer with suspected recurrence on the scar were consecutively subjected to magnetic resonance imaging (MRI), including use of a diffusion sequence. All patients with pathological enhancement in the scar were then subjected to histological typing. MRI was considered negative in the absence of areas of suspicious enhancement. In all cases it was measured the ADC value in the scar area or in the area with pathological enhancement. The ADC values were compared with MRI findings and histological results obtained. Results: 26 cases were positive/doubtful at MRI and then subjected to histological typing: of these recurrences were 20 and benign were 6. 46 cases were judged negative at MRI and therefore not sent to cyto-histology. The average ADC value of recurrences was statistically lower of scarring (p < 0.001). Conclusions: ADC value can be a specific parameter in differential diagnosis between recurrence and scar. The diffusion sequence, in association with the morphological and dynamic sequences, can be considered a promising tool for the surgical indication in suspected recurrence of breast cancer.

  5. DWI in breast MRI: Role of ADC value to determine diagnosis between recurrent tumor and surgical scar in operated patients

    International Nuclear Information System (INIS)

    Rinaldi, Pierluigi; Giuliani, Michela; Belli, Paolo; Costantini, Melania; Romani, Maurizio; Distefano, Daniela; Bufi, Enida; Mule, Antonino; Magno, Stefano; Masetti, Riccardo; Bonomo, Lorenzo

    2010-01-01

    Introduction: Purpose of our study is to evaluate the role of the apparent diffusion coefficient (ADC) in the diagnosis of recurrent tumor on the scar in patients operated for breast cancer. Assess, therefore, the weight of diagnostic diffusion echo-planar sequence, in association with the morphological and dynamic sequences in the diagnosis of tumor recurrence versus surgical scar. Materials and methods: From September 2007 to March 2009, 72 patients operated for breast cancer with suspected recurrence on the scar were consecutively subjected to magnetic resonance imaging (MRI), including use of a diffusion sequence. All patients with pathological enhancement in the scar were then subjected to histological typing. MRI was considered negative in the absence of areas of suspicious enhancement. In all cases it was measured the ADC value in the scar area or in the area with pathological enhancement. The ADC values were compared with MRI findings and histological results obtained. Results: 26 cases were positive/doubtful at MRI and then subjected to histological typing: of these recurrences were 20 and benign were 6. 46 cases were judged negative at MRI and therefore not sent to cyto-histology. The average ADC value of recurrences was statistically lower of scarring (p < 0.001). Conclusions: ADC value can be a specific parameter in differential diagnosis between recurrence and scar. The diffusion sequence, in association with the morphological and dynamic sequences, can be considered a promising tool for the surgical indication in suspected recurrence of breast cancer.

  6. PDC: A wire chamber cathode read-out on 6-bit fast ADC

    Energy Technology Data Exchange (ETDEWEB)

    De Giorgi, M; Gasparini, F; Meneguzzo, A T; Pitacco, G [Istituto Nazionale di Fisica Nucleare, Padua (Italy); Padua Univ. (Italy). Ist. di Fisica)

    1984-06-01

    A read-out for MWPC and drift chamber is presented in which the coordinate along the sense wires is obtained by measuring the centre of gravity (CoG) of the charge induced on cathode strips or pads. The peak value of the signals coming from subsets of 8-pad cathodes are recorded by a parallel sample and hold, strobed by their own OR, and then serially digitized by one 6-bit fast ADC (FADC). The basic module of the system is a peak detector and converter (PDC) built in CAMAC cards, which could be an interesting approach to the analog signal acquisition of large particle detectors. The system has been designed to equip the central detector in an experiment at the CERN LEAR facility. A prototype of a card will be described and the results of some tests will be presented.

  7. A Fast Multiple Sampling Method for Low-Noise CMOS Image Sensors With Column-Parallel 12-bit SAR ADCs

    Directory of Open Access Journals (Sweden)

    Min-Kyu Kim

    2015-12-01

    Full Text Available This paper presents a fast multiple sampling method for low-noise CMOS image sensor (CIS applications with column-parallel successive approximation register analog-to-digital converters (SAR ADCs. The 12-bit SAR ADC using the proposed multiple sampling method decreases the A/D conversion time by repeatedly converting a pixel output to 4-bit after the first 12-bit A/D conversion, reducing noise of the CIS by one over the square root of the number of samplings. The area of the 12-bit SAR ADC is reduced by using a 10-bit capacitor digital-to-analog converter (DAC with four scaled reference voltages. In addition, a simple up/down counter-based digital processing logic is proposed to perform complex calculations for multiple sampling and digital correlated double sampling. To verify the proposed multiple sampling method, a 256 × 128 pixel array CIS with 12-bit SAR ADCs was fabricated using 0.18 μm CMOS process. The measurement results shows that the proposed multiple sampling method reduces each A/D conversion time from 1.2 μs to 0.45 μs and random noise from 848.3 μV to 270.4 μV, achieving a dynamic range of 68.1 dB and an SNR of 39.2 dB.

  8. SU-F-303-13: Initial Evaluation of Four Dimensional Diffusion- Weighted MRI (4D-DWI) and Its Effect On Apparent Diffusion Coefficient (ADC) Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y [Duke University Medical Physics Program (United States); Yin, F; Czito, B; Bashir, M; Palta, M; Cai, J [Duke University Medical Center, Durham, NC (United States); Zhong, X; Dale, B [Siemens Healthcare, Durham, NC (United States)

    2015-06-15

    Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.The technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15

  9. A third generation personality test

    OpenAIRE

    Sjöberg, Lennart

    2010-01-01

    The development of personality testing in the workplace has undergone three phases. The first generation of tests, such as Cattell’s 16 PF and the British test OPQ, was characterized by complex systems for the description of the personality. These systems were simplified in part by the following generation of the test, which was based on the five factor model but that model was simple only at the horizontal level. Beneath the five main factors were a large number of ancillary factors, usually...

  10. A 14-bit 50 MS/s sample-and-hold circuit for pipelined ADC

    International Nuclear Information System (INIS)

    Yue Sen; Zhao Yiqiang; Pang Ruilong; Sheng Yun

    2014-01-01

    A high performance sample-and-hold (S/H) circuit used in a pipelined analog-to-digital converter (ADC) is presented. Capacitor flip-around architecture is used in this S/H circuit with a novel gain-boosted differential folded cascode operational transconductance amplifier. A double-bootstrapped switch is designed to improve the performance of the circuit. The circuit is implemented using a 0.18 μm 1P6M CMOS process. Measurement results show that the effective number of bits is 14.03 bits, the spurious free dynamic range is 94.62 dB, the signal to noise and distortion ratio is 86.28 dB, and the total harmonic distortion is −91:84 dB for a 5 MHz input signal with 50 MS/s sampling rate. A pipeline ADC with the designed S/H circuit has been implemented. (semiconductor integrated circuits)

  11. Analog automatic test pattern generation for quasi-static structural test.

    NARCIS (Netherlands)

    Zjajo, A.; Pineda de Gyvez, J.

    2009-01-01

    A new approach for structural, fault-oriented analog test generation methodology to test for the presence of manufacturing-related defects is proposed. The output of the test generator consists of optimized test stimuli, fault coverage and sampling instants that are sufficient to detect the failure

  12. A continuous-time sigma delta ADC with increased immunity to wide-band interferers

    NARCIS (Netherlands)

    Philips, K.J.P.; Nuijten, P.A.C.M.; Roovers, R.L.J.; Roermund, van A.H.M.; Munoz Chavero, F.; Tejero Pallarés, M.; Torralba, A.

    2004-01-01

    Receivers are being digitized in a quest for flexibility. Analog filters and programmable gain stages are being exchanged for digital processing at the price of a very challenging ADC. This paper presents an alternative solution where the filter and programmable gain functionality is integrated into

  13. Generator acceptance test and inspection report

    International Nuclear Information System (INIS)

    Johns, B.R.

    1997-01-01

    This Acceptance Test Report(ATR) is the completed testing and inspection of the new portable generator. The testing and inspection is to verify that the generator provided by the vendor meets the requirements of specification WHC-S-0252, Revision 2. Attached is various other documentation to support the inspection and testing

  14. Utilisation et qualification d'un débitmètre à effet doppler (ADC) sur une rivière intermittente

    OpenAIRE

    Marchand, Pierre; Salles, C.; Rodier, C.; Hernandez, Frédéric; Gayrard, E.; Tournoud, M. G.

    2014-01-01

    Intermittent rivers pose different challenges to stream rating due to high spatial and temporal gradients. Long dry periods, cut by short duration flush flood events explain the difficulty to obtain reliable discharge data, for low flows as well as for floods: problems occur with standard gauging, zero flow period, etc. Our study aims to test the use of an acoustic Doppler current meter (ADC) for improving stream rating curves in small catchments subject to large variations of discharge, soli...

  15. Normal hepatic parenchyma visibility and ADC quantification on diffusion-weighted MRI at 3 T: influence of age, gender, and iron content

    Energy Technology Data Exchange (ETDEWEB)

    Metens, Thierry [MRI Clinics, Department of Radiology, Hopital Erasme, Bruxelles (Belgium); Universite Libre de Bruxelles, Magnetic Resonance Imaging Clinics, Department of Radiology, Hopital Erasme, Bruxelles (Belgium); Ferraresi, Kellen Fanstone; Farchione, Alessandra; Bali, Maria Antonietta; Matos, Celso [MRI Clinics, Department of Radiology, Hopital Erasme, Bruxelles (Belgium); Moreno, Christophe [Universite Libre de Bruxelles, Department of Gastroenterology, Hepatopancreatology, and Digestive Oncology, Hopital Erasme, Bruxelles (Belgium)

    2014-12-15

    To investigate how normal liver parenchyma visibility on 3 T diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) quantification are influenced by age, gender, and iron content. Between February 2011 and April 2013, 86 patients (52 women) with normal livers who underwent respiratory-triggered abdominal 3 T DWI (b = 0, 150, 600, 1,000 s/mm{sup 2}) were retrospectively included. Normal liver and spleen parenchyma visibility was scored independently by two readers. Correlations between visibility scores or ADC with age, gender, T2*, or recent serum ferritin (SF) were investigated. Liver visibility scores in b = 1,000 s/mm{sup 2} images correlated with the age (Spearman R = -0.56 in women, -0.45 in men), T2* (R = 0.75) and SF (R = -0.64) and were significantly higher in women (P < 0.01). SF and T2* were within normal values (T2*: 13 - 31 ms, SF: 14 - 230 μg/L). Liver ADC correlated with visibility scores (R = 0.69) and T2* (R = 0.64) and was age- and gender-dependent. ADC ROI standard deviation negatively correlated with visibility scores (R = -0.65) and T2* (R = -0.62). The spleen visibility did not depend on age or gender. Normal liver parenchyma visibility in DWI is age- and gender-dependent, according to the iron content. Visibility scores and iron content significantly affect ADC quantification in the normal liver. (orig.)

  16. Normal hepatic parenchyma visibility and ADC quantification on diffusion-weighted MRI at 3 T: influence of age, gender, and iron content

    International Nuclear Information System (INIS)

    Metens, Thierry; Ferraresi, Kellen Fanstone; Farchione, Alessandra; Bali, Maria Antonietta; Matos, Celso; Moreno, Christophe

    2014-01-01

    To investigate how normal liver parenchyma visibility on 3 T diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) quantification are influenced by age, gender, and iron content. Between February 2011 and April 2013, 86 patients (52 women) with normal livers who underwent respiratory-triggered abdominal 3 T DWI (b = 0, 150, 600, 1,000 s/mm 2 ) were retrospectively included. Normal liver and spleen parenchyma visibility was scored independently by two readers. Correlations between visibility scores or ADC with age, gender, T2*, or recent serum ferritin (SF) were investigated. Liver visibility scores in b = 1,000 s/mm 2 images correlated with the age (Spearman R = -0.56 in women, -0.45 in men), T2* (R = 0.75) and SF (R = -0.64) and were significantly higher in women (P < 0.01). SF and T2* were within normal values (T2*: 13 - 31 ms, SF: 14 - 230 μg/L). Liver ADC correlated with visibility scores (R = 0.69) and T2* (R = 0.64) and was age- and gender-dependent. ADC ROI standard deviation negatively correlated with visibility scores (R = -0.65) and T2* (R = -0.62). The spleen visibility did not depend on age or gender. Normal liver parenchyma visibility in DWI is age- and gender-dependent, according to the iron content. Visibility scores and iron content significantly affect ADC quantification in the normal liver. (orig.)

  17. An 8 bit 1 MS/s SAR ADC with 7.72-ENOB

    Science.gov (United States)

    Duan, Jihai; Zhu, Zhiyong; Deng, Jinli; Xu, Weilin

    2017-08-01

    This paper presents a low power 8-bit 1 MS/s SAR ADC with 7.72-bit ENOB. Without an op-amp, an improved segmented capacitor DAC is proposed to reduce the capacitance and the chip area. A dynamic latch comparator with output offset voltage storage technology is used to improve the precision. Adding an extra positive feedback in the latch is to increase the speed. What is more, two pairs of CMOS switches are utilized to eliminate the kickback noise introduced by the latch. The proposed SAR ADC was fabricated in SMIC 0.18 {{μ }}{{m}} CMOS technology. The measured results show that this design achieves an SFDR of 61.8 dB and an ENOB of 7.72 bits, and it consumes 67.5 μW with the FOM of 312 fJ/conversion-step at 1 MS/s sample under 1.8 V power supply. Project supported by the National Natural Science Foundation of China (Nos. 61161003, 61264001, 61166004) and the Guangxi Key Laboratory of Precision Navigation Technology and Application Foundation (No. DH201501).

  18. The 8 bits 100 MS/s Pipeline ADC for the INNOTEP Project – TWEPP-09

    CERN Document Server

    Crampon, S; Chanal, H; Lecoq, J; Mathez, H; Vert, P E

    2009-01-01

    This paper describes the Analog to Digital Converter developed for the front end electronic of the IN2P3 INNOTEP project by the “pole microelectronique Rhone-Auvergne”. (Collaboration between LPC Clermont-Ferrand and IPNL Lyon). This ADC is a 4 stages 2.5 bits per stage pipe line with open loops track and holds and amplifiers. It runs at 100MSamples/s and has 8 bits resolution. The stages used two lines, the gain line and the comparison line, with most operators running in current. The main idea of this current line is to make a first step toward an all in current structure. Currently, this ADC is designed with a 0,35μm SiGe technology.

  19. Improved method for SNR prediction in machine-learning-based test

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.

    2010-01-01

    This paper applies an improved method for testing the signal-to-noise ratio (SNR) of Analogue-to-Digital Converters (ADC). In previous work, a noisy and nonlinear pulse signal is exploited as the input stimulus to obtain the signature results of ADC. By applying a machine-learning-based approach,

  20. ADC as a useful diagnostic tool for differentiating benign and malignant vertebral bone marrow lesions and compression fractures: a systematic review and meta-analysis.

    Science.gov (United States)

    Suh, Chong Hyun; Yun, Seong Jong; Jin, Wook; Lee, Sun Hwa; Park, So Young; Ryu, Chang-Woo

    2018-07-01

    To assess the sensitivity and specificity of quantitative assessment of the apparent diffusion coefficient (ADC) for differentiating benign and malignant vertebral bone marrow lesions (BMLs) and compression fractures (CFs) METHODS: An electronic literature search of MEDLINE and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver operating characteristic modelling were performed to evaluate the diagnostic performance of ADC for differentiating vertebral BMLs. Subgroup analysis was performed for differentiating benign and malignant vertebral CFs. Meta-regression analyses according to subject, study and diffusion-weighted imaging (DWI) characteristics were performed. Twelve eligible studies (748 lesions, 661 patients) were included. The ADC exhibited a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.80-0.94) and a pooled specificity of 0.87 (95% CI 0.78-0.93) for differentiating benign and malignant vertebral BMLs. In addition, the pooled sensitivity and specificity for differentiating benign and malignant CFs were 0.92 (95% CI 0.82-0.97) and 0.91 (95% CI 0.87-0.94), respectively. In the meta-regression analysis, the DWI slice thickness was a significant factor affecting heterogeneity (p benign and malignant vertebral BMLs and CFs. • Quantitative assessment of ADC is useful in differentiating vertebral BMLs. • Quantitative ADC assessment for BMLs had sensitivity of 89%, specificity of 87%. • Quantitative ADC assessment for CFs had sensitivity of 92%, specificity of 91%. • The specificity is highest (95%) with thinner (< 5 mm) DWI slice thickness.

  1. LDRD final report: photonic analog-to-digital converter (ADC) technology; TOPICAL

    International Nuclear Information System (INIS)

    Bowers, M; Deri, B; Haigh, R; Lowry, M; Sargis, P; Stafford, R; Tong, T

    1999-01-01

    We report on an LDRD seed program of novel technology development (started by an FY98 Engineering Tech-base project) that will enable extremely high-fidelity analog-to-digital converters for a variety of national security missions. High speed (l0+ GS/s ), high precision (l0+ bits) ADC technology requires extremely short aperture times ((approx)1ps ) with very low jitter requirements (sub 10fs ). These fundamental requirements, along with other technological barriers, are difficult to realize with electronics: However, we outline here, a way to achieve these timing apertures using a novel multi-wavelength optoelectronic short-pulse optical source. Our approach uses an optoelectronic feedback scheme with high optical Q to produce an optical pulse train with ultra-low jitter ( sub 5fs) and high amplitude stability ( and lt;10(sup 10)). This approach requires low power and can be integrated into an optoelectronic integrated circuit to minimize the size. Under this seed program we have demonstrated that the optical feedback mechanism can be used to generate a high Q resonator. This has reduced the technical risk for further development, making it an attractive candidate for outside funding

  2. Improved method for testing susceptibility of Mycobacterium tuberculosis to pyrazinamide.

    OpenAIRE

    Butler, W R; Kilburn, J O

    1982-01-01

    The acid medium required to test susceptibility of Mycobacterium tuberculosis to pyrazinamide (PZA) is a major problem in obtaining reliable test results. Satisfactory growth is usually obtained on Middlebrook and Cohn 7H10 medium at pH 5.5 if albumin-dextrose-catalase (ADC) supplement rather than oleic acid-albumin-dextrose-catalase is used; however, some lots of ADC supplement still fail to support growth at this low pH. A rapid turbidimetric test was developed to determine the growth-suppo...

  3. A 10 bit 200 MS/s pipeline ADC using loading-balanced architecture in 0.18 μm CMOS

    Science.gov (United States)

    Wang, Linfeng; Meng, Qiao; Zhi, Hao; Li, Fei

    2017-07-01

    A new loading-balanced architecture for high speed and low power consumption pipeline analog-to-digital converter (ADC) is presented in this paper. The proposed ADC uses SHA-less, op-amp and capacitor-sharing technique, capacitor-scaling scheme to reduce the die area and power consumption. A new capacitor-sharing scheme was proposed to cancel the extra reset phase of the feedback capacitors. The non-standard inter-stage gain increases the feedback factor of the first stage and makes it equal to the second stage, by which, the load capacitor of op-amp shared by the first and second stages is balanced. As for the fourth stage, the capacitor and op-amp no longer scale down. From the system’s point of view, all load capacitors of the shared OTAs are balanced by employing a loading-balanced architecture. The die area and power consumption are optimized maximally. The ADC is implemented in a 0.18 μm 1P6M CMOS technology, and occupies a die area of 1.2 × 1.2 mm{}2. The measurement results show a 55.58 dB signal-to-noise-and-distortion ratio (SNDR) and 62.97 dB spurious-free dynamic range (SFDR) with a 25 MHz input operating at a 200 MS/s sampling rate. The proposed ADC consumes 115 mW at 200 MS/s from a 1.8 V supply.

  4. High resolution ADC interface to main magnet power supply at the NSLS

    International Nuclear Information System (INIS)

    Bordoley, M.

    1993-01-01

    Previous readings of DCCT were limited to 11 bits of resolution with large offsets and drifts, providing inaccurate data. The current design overcomes this limitation by using Analog Device's AD7703 20 bit serial output ADC to digitize the main magnet DCCT at the power supply, and transmit the data serially at 2KHz over to the VME controller

  5. Electrical design note for a 5000 ADC, 230 μH power supply filter choke

    International Nuclear Information System (INIS)

    Visser, A.T.

    1993-04-01

    This note describes the design of a 5000 ADC, 230 μH choke made from standard transformer cores. Five of these chokes have been made for CDF and MTF. NOTE: Special magnets can also be made using standard cores

  6. Experimental Testing of a Van De Graaff Generator as an Electromagnetic Pulse Generator

    Science.gov (United States)

    2016-07-01

    EXPERIMENTAL TESTING OF A VAN DE GRAAFF GENERATOR AS AN ELECTROMAGNETIC PULSE GENERATOR THESIS...protection in the United States AFIT-ENP-MS-16-S-075 EXPERIMENTAL TESTING OF A VAN DE GRAAFF GENERATOR AS AN ELECTROMAGNETIC PULSE GENERATOR...RELEASE; DISTRIBUTION UNLIMITED. AFIT-ENP-MS-16-S-075 EXPERIMENTAL TESTING OF A VAN DE GRAAFF GENERATOR AS AN ELECTROMAGNETIC PULSE GENERATOR

  7. A Cryogenic 1 GSa/s, Soft-Core FPGA ADC for Quantum Computing Applications

    NARCIS (Netherlands)

    Homulle, H.A.R.; Charbon, E.E.E.

    2016-01-01

    We propose an analog-to-digital converter (ADC) architecture, implemented in an FPGA, that is fully reconfigurable and easy to calibrate. This approach allows to alter the design, according to the system requirements, with simple modifications in the firmware. Therefore it can be used in a wide

  8. ADCS controllers comparison for small satellitess in Low Earth Orbit

    Science.gov (United States)

    Calvo, Daniel; Laverón-Simavilla, Ana; Lapuerta, Victoria

    2016-07-01

    Fuzzy logic controllers are flexible and simple, suitable for small satellites Attitude Determination and Control Subsystems (ADCS). In a previous work, a tailored Fuzzy controller was designed for a nanosatellite. Its performance and efficiency were compared with a traditional Proportional Integrative Derivative (PID) controller within the same specific mission. The orbit height varied along the mission from injection at around 380 km down to 200 km height, and the mission required pointing accuracy over the whole time. Due to both, the requirements imposed by such a low orbit, and the limitations in the power available for the attitude control, an efficient ADCS is required. Both methodologies, fuzzy and PID, were fine-tuned using an automated procedure to grant maximum efficiency with fixed performances. The simulations showed that the Fuzzy controller is much more efficient (up to 65% less power required) in single manoeuvres, achieving similar, or even better, precision than the PID. The accuracy and efficiency improvement of the Fuzzy controller increase with orbit height because the environmental disturbances decrease, approaching the ideal scenario. However, the controllers are meant to be used in a vast range of situations and configurations which exceed those used in the calibration process carried out in the previous work. To assess the suitability and performance of both controllers in a wider framework, parametric and statistical methods have been applied using the Monte Carlo technique. Several parameters have been modified randomly at the beginning of each simulation: the moments of inertia of the whole satellite and of the momentum wheel, the residual magnetic dipole and the initial conditions of the test. These parameters have been chosen because they are the main source of uncertainty during the design phase. The variables used for the analysis are the error (critical for science) and the operation cost (which impacts the mission lifetime and

  9. Test Pattern Generator for Mixed Mode BIST

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Sik; Lee, Hang Kyu; Kang, Sung Ho [Yonsei University (Korea, Republic of)

    1998-07-01

    As the increasing integrity of VLSI, the BIST (Built-In Self Test) is used as an effective method to test chips. Generally the pseudo-random test pattern generation is used for BIST. But it requires lots of test patterns when there exist random resistant faults. Therefore deterministic testing is an interesting BIST technique due to the minimal number of test patterns and to its high fault coverage. However this is not applicable since the existing deterministic test pattern generators require too much area overhead despite their efficiency. Therefore we propose a mixed test scheme which applies to the circuit under test, a deterministic test sequence followed by a pseudo-random one. This scheme allows the maximum fault coverage detection to be achieved, furthermore the silicon area overhead of the mixed hardware generator can be reduced. The deterministic test generator is made with a finite state machine and a pseudo-random test generator is made with LFSR(linear feedback shift register). The results of ISCAS circuits show that the maximum fault coverage is guaranteed with small number of test set and little hardware overhead. (author). 15 refs., 10 figs., 4 tabs.

  10. Comparison of apparent diffusion coefficients (ADCs) between two-point and multi-point analyses using high-B-value diffusion MR imaging

    International Nuclear Information System (INIS)

    Kubo, Hitoshi; Maeda, Masayuki; Araki, Akinobu

    2001-01-01

    We evaluated the accuracy of calculating apparent diffusion coefficients (ADCs) using high-B-value diffusion images. Echo planar diffusion-weighted MR images were obtained at 1.5 tesla in five standard locations in six subjects using gradient strengths corresponding to B values from 0 to 3000 s/mm 2 . Estimation of ADCs was made using two methods: a nonlinear regression model using measurements from a full set of B values (multi-point method) and linear estimation using B values of 0 and max only (two-point method). A high correlation between the two methods was noted (r=0.99), and the mean percentage differences were -0.53% and 0.53% in phantom and human brain, respectively. These results suggest there is little error in estimating ADCs calculated by the two-point technique using high-B-value diffusion MR images. (author)

  11. Test generation for hierarchical functionalswitching structures

    OpenAIRE

    LYULKIN A.; LINNIK I.

    2003-01-01

    A problem of test generation for logic CMOS circuits is solved with regard to an extended class of faults. The well-known D-algorithm for test generation for stuck-at faults is extended for transistor stuck-open faults. It is shown that a test for transistor stuck-open faults may be constructed on the base of the test for stuck-at faults. A problem of length minimization of constructed test is discussed.

  12. Test Generator for MATLAB Simulations

    Science.gov (United States)

    Henry, Joel

    2011-01-01

    MATLAB Automated Test Tool, version 3.0 (MATT 3.0) is a software package that provides automated tools that reduce the time needed for extensive testing of simulation models that have been constructed in the MATLAB programming language by use of the Simulink and Real-Time Workshop programs. MATT 3.0 runs on top of the MATLAB engine application-program interface to communicate with the Simulink engine. MATT 3.0 automatically generates source code from the models, generates custom input data for testing both the models and the source code, and generates graphs and other presentations that facilitate comparison of the outputs of the models and the source code for the same input data. Context-sensitive and fully searchable help is provided in HyperText Markup Language (HTML) format.

  13. High resolution ADC interface to main magnet power supply at the NSLS

    Energy Technology Data Exchange (ETDEWEB)

    Bordoley, M.

    1993-07-01

    Previous readings of DCCT were limited to 11 bits of resolution with large offsets and drifts, providing inaccurate data. The current design overcomes this limitation by using Analog Device`s AD7703 20 bit serial output ADC to digitize the main magnet DCCT at the power supply, and transmit the data serially at 2KHz over to the VME controller.

  14. High resolution ADC interface to main magnet power supply at the NSLS

    Energy Technology Data Exchange (ETDEWEB)

    Bordoley, M.

    1993-01-01

    Previous readings of DCCT were limited to 11 bits of resolution with large offsets and drifts, providing inaccurate data. The current design overcomes this limitation by using Analog Device's AD7703 20 bit serial output ADC to digitize the main magnet DCCT at the power supply, and transmit the data serially at 2KHz over to the VME controller.

  15. Neutron generator instrumentation at the Department 2350 Neutron Generator Test Facility

    International Nuclear Information System (INIS)

    Bryant, T.C.; Mowrer, G.R.

    1979-06-01

    The computer and waveform digitizing capability at the test facility has allowed several changes in the techniques used to test neutron generators. These changes include methods used to calibrate the instrumentation and changes in the operation of the test facility. These changes have increased the efficiency of the test facility as well as increasing both timing and amplitude accuracy of neutron generator waveforms

  16. Testing installation for a steam generator

    International Nuclear Information System (INIS)

    Dubourg, M.

    1985-01-01

    The invention proposes a testing installation for a steam generator associated to a boiler, comprising a testing exchanger connected to a feeding circuit in secondary fluid and to a circuit to release the steam produced, and comprising a heating-tube bundle connected to a closed circuit of circulation of a primary coolant at the same temperature and at the pressure than the primary fluid. The heating-tube bundle of the testing exchanger has the same height than the primary bundle of the steam generator and the testing exchanger is at the same level and near the steam generator and is fed by the same secondary fluid such as it is subject to the same operation phases during a long period. The in - vention applies, more particularly, to the steam generators of pressurized water nuclear power plants [fr

  17. A 12-bit SAR ADC integrated on a multichannel silicon drift detector readout IC

    Energy Technology Data Exchange (ETDEWEB)

    Schembari, F., E-mail: filippo.schembari@polimi.it [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, via Golgi 40, 20133 Milano (Italy); INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Bellotti, G.; Fiorini, C. [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, via Golgi 40, 20133 Milano (Italy); INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy)

    2016-07-11

    A 12-bit analog-to-digital converter (ADC) addressed to Silicon-Drift Detectors (SDDs) multichannel readout ASICs for X- and gamma-ray applications is presented. Aiming at digitizing output multiplexed data from the upstream analog filters banks, the converter must ensure 11-bit accuracy and a sampling frequency of about 5 MS/s. The ADC architecture is the charge-redistribution (CR) successive-approximation register (SAR). A fully differential topology has also been chosen for better rejection of common-mode noise and disturbances. The internal DAC is made of binary-scaled capacitors, whose bottom plates are switched by the SAR logic to perform the binary search of the analog input value by means of the monotonic switching scheme. The A/D converter is integrated on SFERA, a multichannel ASIC fabricated in a standard CMOS 0.35 μm 3.3 V technology and it occupies an area of 0.42 mm{sup 2}. Simulated static performance shows monotonicity over the whole input–output characteristic. The description of the circuit topology and of inner blocks architectures together with the experimental characterization is here presented. - Highlights: • X- and γ-ray spectroscopy front-ends need to readout a high number of detectors. • Design efforts are increasingly oriented to compact and low-power ASICs. • A possible solution is the on-chip integration of the analog-to-digital converter. • A 12-bit CR successive-approximation-register ADC has been developed. • It is a suitable candidate as the digitizer to be integrated in multichannel ASICs.

  18. Particle identification via pulse-shape discrimination with a charge-integrating ADC

    International Nuclear Information System (INIS)

    Heltsley, J.H.; Brandon, L.; Galonsky, A.; Heilbronn, L.; Remington, B.A.; Langer, S.; Van der Molen, A.; Yurkon, J.; Michigan State Univ., East Lansing; Kasagi, J.

    1988-01-01

    A charge-integrating ADC has been used to sample the intensity in two different time regions of a pulse and thus to sense the shape of the pulse. This idea has been applied to produce neutron/γ-ray discrimination from pulses in a liquid scintillation detector. Optimization of available parameters yields good pulse-shape discrimination for pulses greater than those produced by 100 keV electrons. The method uses only general purpose electronics. (orig.)

  19. A case of a resectable single hepatic epithelioid hemangioendothelioma with characteristic imaging by ADC map.

    Science.gov (United States)

    Okano, Hiroshi; Nakajima, Hideki; Tochio, Tomomasa; Suga, Daisuke; Kumazawa, Hiroaki; Isono, Yoshiaki; Tanaka, Hiroki; Matsusaki, Shimpei; Sase, Tomohiro; Saito, Tomonori; Mukai, Katsumi; Nishimura, Akira; Matsushima, Nobuyoshi; Baba, Youichirou; Murata, Tetsuya; Hamada, Takashi; Taoka, Hiroki

    2015-12-01

    A 47-year-old woman with a single-nodule hepatic tumor was referred to our hospital. She had no symptoms. The tumor was located at the surface of the right lobe of the liver; it showed peripheral low signal intensity on a magnetic resonance imaging apparent diffusion coefficient (ADC) map, and an influx of blood flow into the peripheral area of the tumor at the early vascular phase on perflubutane microbubble (Sonazoid(®)) contrast-enhanced (CE) ultrasonography. Since we suspected a malignant tumor, the patient underwent surgical resection. The hepatic tumor was resected curatively. Pathological examination revealed that the tumor was composed of epithelioid cells with an epithelioid structure and/or cord-like structure. Immunohistochemical staining was positive for cluster of differentiation 34 and factor VIII-related antigen. Based on the above, a final diagnosis of hepatic epithelioid hemangioendothelioma (EHE) was made. Hepatic EHE is a rare hepatic tumor: only a few cases of hepatic EHE with curative resection have been reported. We were unable to reach a diagnosis of hepatic EHE by imaging studies; however, an ADC map was useful in showing the malignant potential of the tumor, and CE ultrasonography was useful in revealing the peripheral blood flow of the tumor. When an unusual hepatic mass is encountered, hepatic EHE should be kept in mind, and the mass should be inspected with more than one imaging modality, including an ADC map, in the process of differential diagnosis.

  20. Gd-EOB-DTPA-Enhanced MR Imaging of the Liver: The Effect on T2 Relaxation Times and Apparent Diffusion Coefficient (ADC)

    International Nuclear Information System (INIS)

    Cieszanowski, Andrzej; Podgórska, Joanna; Rosiak, Grzegorz; Maj, Edyta; Grudziński, Ireneusz P.; Kaczyński, Bartosz; Szeszkowski, Wojciech; Milczarek, Krzysztof; Rowiński, Olgierd

    2016-01-01

    To investigate the effect of gadoxetic acid disodium (Gd-EOB-DTPA) on T2 relaxation times and apparent diffusion coefficient (ADC) values of the liver and focal liver lesions on a 1.5-T system. Magnetic resonance (MR) studies of 50 patients with 35 liver lesions were retrospectively analyzed. All examinations were performed at 1.5T and included T2-weighted turbo spin-echo (TSE) and diffusion-weighted (DW) images acquired before and after intravenous administration of Gd-EOB-DTPA. To assess the effect of this hepatobiliary contrast agent on T2-weighted TSE images and DW images T2 relaxation times and ADC values of the liver and FLLs were calculated and compared pre- and post-injection. The mean T2 relaxation times of the liver and focal hepatic lesions were lower on enhanced than on unenhanced T2-weighted TSE images (decrease of 2.7% and 3.6% respectively), although these differences were not statistically significant. The mean ADC values of the liver showed statistically significant decrease (of 4.6%) on contrast-enhanced DW images, compared to unenhanced images (P>0.05). The mean ADC value of liver lesions was lower on enhanced than on unenhanced DW images, but this difference (of 2.9%) did not reach statistical significance. The mean T2 relaxation times of the liver and focal liver lesions as well as the mean ADC values of liver lesions were not significantly different before and after administration of Gd-EOB-DTPA. Therefore, acquisition of T2-weighted and DW images between the dynamic contrast-enhanced examination and hepatobiliary phase is feasible and time-saving

  1. Photonic-assisted time-interleaved ADC based on optical delay line

    International Nuclear Information System (INIS)

    Xu, Chen; Zheng, Shilie; Chen, Xinyi; Chi, Hao; Jin, Xiaofeng; Zhang, Xianmin

    2016-01-01

    An approach to implement photonic-assisted time-interleaved analog-to-digital conversion and its calibration method are presented. The analog modulated optical signal is divided into M channels, suffering different time delay induced by optical delay lines which provide great flexibility in producing time intervals and is then sampled by electronic analog-to-digital converters (ADCs). The channel mismatches resulting in performance degradation are estimated by a modified sine wave fitting method. The time mismatch and other mismatches are corrected by fine optical delay adjustment and digital processing, respectively. A four-channel photonic-assisted time-interleaved analog-to-digital converter (TIADC) system operating at 40 GSa s −1 was demonstrated experimentally. The photonic-assisted TIADC system was tested with a 6.31 GHz sine wave signal, exhibiting 40.3 dB signal-to-noise and distortion ratio (SINAD) and 57.6 dBc spurious-free dynamic range (SFDR). It is shown that the SINAD is dominated by the signal-to-noise ratio (SNR) of the analog optical link and the SFDR of the proposed system is limited by the linearity of the link. (paper)

  2. A single-channel 10-bit 160 MS/s SAR ADC in 65 nm CMOS

    International Nuclear Information System (INIS)

    Lu Yuxiao; Sun Lu; Li Zhe; Zhou Jianjun

    2014-01-01

    This paper demonstrates a single-channel 10-bit 160 MS/s successive-approximation-register (SAR) analog-to-digital converter (ADC) in 65 nm CMOS process with a 1.2 V supply voltage. To achieve high speed, a new window-opening logic based on the asynchronous SAR algorithm is proposed to minimize the logic delay, and a partial set-and-down DAC with binary redundancy bits is presented to reduce the dynamic comparator offset and accelerate the DAC settling. Besides, a new bootstrapped switch with a pre-charge phase is adopted in the track and hold circuits to increase speed and reduce area. The presented ADC achieves 52.9 dB signal-to-noise distortion ratio and 65 dB spurious-free dynamic range measured with a 30 MHz input signal at 160 MHz clock. The power consumption is 9.5 mW and a core die area of 250 × 200 μm 2 is occupied. (semiconductor integrated circuits)

  3. Haralick texture features from apparent diffusion coefficient (ADC) MRI images depend on imaging and pre-processing parameters.

    Science.gov (United States)

    Brynolfsson, Patrik; Nilsson, David; Torheim, Turid; Asklund, Thomas; Karlsson, Camilla Thellenberg; Trygg, Johan; Nyholm, Tufve; Garpebring, Anders

    2017-06-22

    In recent years, texture analysis of medical images has become increasingly popular in studies investigating diagnosis, classification and treatment response assessment of cancerous disease. Despite numerous applications in oncology and medical imaging in general, there is no consensus regarding texture analysis workflow, or reporting of parameter settings crucial for replication of results. The aim of this study was to assess how sensitive Haralick texture features of apparent diffusion coefficient (ADC) MR images are to changes in five parameters related to image acquisition and pre-processing: noise, resolution, how the ADC map is constructed, the choice of quantization method, and the number of gray levels in the quantized image. We found that noise, resolution, choice of quantization method and the number of gray levels in the quantized images had a significant influence on most texture features, and that the effect size varied between different features. Different methods for constructing the ADC maps did not have an impact on any texture feature. Based on our results, we recommend using images with similar resolutions and noise levels, using one quantization method, and the same number of gray levels in all quantized images, to make meaningful comparisons of texture feature results between different subjects.

  4. Automatic generation of combinatorial test data

    CERN Document Server

    Zhang, Jian; Ma, Feifei

    2014-01-01

    This book reviews the state-of-the-art in combinatorial testing, with particular emphasis on the automatic generation of test data. It describes the most commonly used approaches in this area - including algebraic construction, greedy methods, evolutionary computation, constraint solving and optimization - and explains major algorithms with examples. In addition, the book lists a number of test generation tools, as well as benchmarks and applications. Addressing a multidisciplinary topic, it will be of particular interest to researchers and professionals in the areas of software testing, combi

  5. Prototype steam generator test at SCTI/ETEC. Acoustic program test plan

    International Nuclear Information System (INIS)

    Greene, D.A.; Thiele, A.; Claytor, T.N.

    1981-10-01

    This document is an integrated test plan covering programs at General Electric (ARSD), Rockwell International (RI) and Argonne National Laboratory (CT). It provides an overview of the acoustic leak detection test program which will be completed in conjunction with the prototype LMFBR steam generator at the Energy Technology Engineering Laboratory. The steam generator is installed in the Sodium Components Test Installation (SCTI). Two acoustic detection systems will be used during the test program, a low frequency system developed by GE-ARSD (GAAD system) and a high frequency system developed by RI-AI (HALD system). These systems will be used to acquire data on background noise during the thermal-hydraulic test program. Injection devices were installed during fabrication of the prototype steam generator to provide localized noise sources in the active region of the tube bundle. These injectors will be operated during the steam generator test program, and it will be shown that they are detected by the acoustic systems

  6. A reconfigurable medically cohesive biomedical front-end with ΣΔ ADC in 0.18µm CMOS.

    Science.gov (United States)

    Jha, Pankaj; Patra, Pravanjan; Naik, Jairaj; Acharya, Amit; Rajalakshmi, P; Singh, Shiv Govind; Dutta, Ashudeb

    2015-08-01

    This paper presents a generic programmable analog front-end (AFE) for acquisition and digitization of various biopotential signals. This includes a lead-off detection circuit, an ultra-low current capacitively coupled signal conditioning stage with programmable gain and bandwidth, a new mixed signal automatic gain control (AGC) mechanism and a medically cohesive reconfigurable ΣΔ ADC. The full system is designed in UMC 0.18μm CMOS. The AFE achieves an overall linearity of more 10 bits with 0.47μW power consumption. The ADC provides 2(nd) order noise-shaping while using single integrator and an ENOB of ~11 bits with 5μW power consumption. The system was successfully verified for various ECG signals from PTB database. This system is intended for portable batteryless u-Healthcare devices.

  7. Thermal hydraulic studies in steam generator test facility

    International Nuclear Information System (INIS)

    Vinod, V.; Suresh Kumar, V.A.; Noushad, I.B.; Ellappan, T.R.; Rajan, K.K.; Rajan, M.; Vaidyanathan, G.

    2005-01-01

    Full text of publication follows: A 500 MWe fast breeder reactor is being constructed at Kalpakkam, India. This is a sodium cooled reactor with two primary and two secondary sodium loops with total 8 steam generators. The typical advantage of fast breeder plants is the high operating temperature of steam cycles and the high plant efficiency. To produce this high pressure and high temperature steam, once through straight tube vertical sodium heated steam generators are used. The steam is generated from the heat produced in the reactor core and being transported through primary and secondary sodium circuits. The steam generator is a 25 m high middle supported steam generator with expansion bend and 23 m heat transfer length. Steam Generator Test Facility (SGTF) constructed at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam aims at performing various tests on a 5.5 MWt steam generator. This vertically simulated test article is similar in all respects to the proposed 157 MWt steam generator module for the Prototype Fast Breeder Reactor (PFBR), with reduced number of tubes. Heat transfer performance tests are done with this 19 tube steam generator at various load conditions. Sodium circuit for the SGTF is equipped with oil fired heater as heat source and centrifugal sodium pump, to pump sodium at 105 m 3 /hr flow rate. Other typical components like sodium to air heat exchanger, sodium purification system and hydrogen leak detection system is also present in the sodium circuit. High pressure steam produced in the steam generator is dumped in a condenser and recycled. Important tests planned in SGTF are the heat transfer performance test, stability test, endurance test and performance test of steam generator under various transients. The controlled operation of steam generator will be studied with possible control schemes. A steady state simulation of the steam generator is done with a mathematical model. This paper gives the details of heat transfer

  8. 17 bit 4.35 mW 1 kHz Delta Sigma ADC and 256-to-1 multiplexer for remote handling instrumentation equipment

    Energy Technology Data Exchange (ETDEWEB)

    Verbeeck, Jens, E-mail: jens.verbeeck@esat.kuleuven.be [KU Leuven, Department ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); KH Kempen University College, IBW-RELIC, Kleinhoefstraat 4, 2440 Geel (Belgium); Van Uffelen, Marco [Fusion for Energy, c/Josep, n° 2, Torres Diagonal Litoral, Ed. B3, 08019 Barcelona (Spain); Steyaert, Michiel [KU Leuven, Department ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Leroux, Paul [KU Leuven, Department ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); KH Kempen University College, IBW-RELIC, Kleinhoefstraat 4, 2440 Geel (Belgium)

    2013-10-15

    Highlights: ► We present a radiation hard 17 bit-1 kHz 4.35 mW Delta Sigma ADC. ► A radiation tolerant 256-to-1 multiplexer is shown. ► We propose a generic radiation tolerant ASIC for use in an instrumentation link. ► The ASIC can interface more than hundred pressure or resistive sensors. ► All building blocks have a simulated radiation tolerance of more than 1 MGy. -- Abstract: A radiation tolerant Delta-Sigma Analog-to-Digital Converter (ADC) and multiplexer is presented. The design features a 1.5 V, 17 bit ADC consuming 4.35 mW at a sample frequency of 1 MHz. The ADC features a bandwidth of 1 kHz and utilizes a Correlated Double Sampling technique (CDS) to remove offset and 1/f noise. The circuit maintains its 17 bit resolution upon a simulated radiation dose exceeding 1 MGy and varying temperatures between 0 °C and 85 °C. Next a multiplexer is presented. It can multiplex 256 channels at a clock frequency of 128 MHz or has a data throughput of 256 MSample/s. In addition the bit period of the multiplexer varies less then 1.5% due to the influence of temperature or radiation, which proves the temperature and radiation tolerance.

  9. Presenting automatic demand control (ADC) as a new frequency control method in smart grids

    Energy Technology Data Exchange (ETDEWEB)

    Ameli, Mohammad Taghi; Ameli, Ali; Maleki, Hamed [Power and Water Univ. of Technology, Tehran (Iran, Islamic Republic of); Mobarhani, Alireza [Amir Kabir Univ. of Technology, Tehran (Iran, Islamic Republic of)

    2011-07-01

    Electric power is the most important part of human energy consumption, and since it has a low storage coefficient it is of particular importance to establish a balance in demand and generation in order to modify and optimize consumption patterns. The expression ''Smart Grid'' can be used to describe technologies which are applied for the automation and optimization of the generation, transmission and distribution network management. This technology requires the integration of information and communication technology in electrical network operation. This paper will study how the Smart Grid capabilites can be used to manage and optimize power network consumption, as well as how the consumers collaboration process using an AGC (Automatic Generation Control) system acts to provide secondary frequency control through consumed load shedding. Reestablishing the balance between demand and generation in critical network operation is also investigated. In other words, utilizing the above method, a new system, ADC (Automatic Demand Control), is offered for use alongside the AGC system in Smart Grids to restore the frequency value to its nominal value. This can lead to a more competitive electricity market and reduce the system storage while maintaining adequate security and network reliability. One of the benefits of the proposed methods described in this paper, in addition to restoring the frequency value to its nominal value, is lower costs and a more economic network operation through reducing fuel and CO2 emission by managing and controlling the amount of the consumed load in the Smart Grid. Also consumers are given the capability to have a specific timetable to economize on their energy requirements which will also reduce the load peak and the network losses. (orig.)

  10. Relativistic decay widths of autoionization processes: The relativistic FanoADC-Stieltjes method

    Energy Technology Data Exchange (ETDEWEB)

    Fasshauer, Elke, E-mail: Elke.Fasshauer@uit.no [Centre for Theoretical and Computational Chemistry, Department of Chemistry, University of Tromsø–The Arctic University of Norway, N-9037 Tromsø (Norway); Theoretische Chemie, Universität Heidelberg, Im Neuenheimer Feld 229, D-69120 Heidelberg (Germany); Kolorenč, Přemysl [Institute of Theoretical Physics, Faculty of Mathematics and Physics, Charles University in Prague, V Holešovičkách 2, 180 00 Prague (Czech Republic); Pernpointner, Markus [Theoretische Chemie, Universität Heidelberg, Im Neuenheimer Feld 229, D-69120 Heidelberg (Germany)

    2015-04-14

    Electronic decay processes of ionized systems are, for example, the Auger decay or the Interatomic/ Intermolecular Coulombic Decay. In both processes, an energetically low lying vacancy is filled by an electron of an energetically higher lying orbital and a secondary electron is instantaneously emitted to the continuum. Whether or not such a process occurs depends both on the energetic accessibility and the corresponding lifetime compared to the lifetime of competing decay mechanisms. We present a realization of the non-relativistically established FanoADC-Stieltjes method for the description of autoionization decay widths including relativistic effects. This procedure, being based on the Algebraic Diagrammatic Construction (ADC), was adapted to the relativistic framework and implemented into the relativistic quantum chemistry program package Dirac. It is, in contrast to other existing relativistic atomic codes, not limited to the description of autoionization lifetimes in spherically symmetric systems, but is instead also applicable to molecules and clusters. We employ this method to the Auger processes following the Kr3d{sup −1}, Xe4d{sup −1}, and Rn5d{sup −1} ionization. Based on the results, we show a pronounced influence of mainly scalar-relativistic effects on the decay widths of autoionization processes.

  11. 21 CFR 882.1430 - Electroencephalograph test signal generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroencephalograph test signal generator. 882.1430 Section 882.1430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Electroencephalograph test signal generator. (a) Identification. An electroencephalograph test signal generator is a...

  12. Time-Optimal Real-Time Test Case Generation using UPPAAL

    DEFF Research Database (Denmark)

    Hessel, Anders; Larsen, Kim Guldstrand; Nielsen, Brian

    2004-01-01

    Testing is the primary software validation technique used by industry today, but remains ad hoc, error prone, and very expensive. A promising improvement is to automatically generate test cases from formal models of the system under test. We demonstrate how to automatically generate real...... test purposes or generated automatically from various coverage criteria of the model.......-time conformance test cases from timed automata specifications. Specifically we demonstrate how to fficiently generate real-time test cases with optimal execution time i.e test cases that are the fastest possible to execute. Our technique allows time optimal test cases to be generated using manually formulated...

  13. Test programmes of HTTR for future generation HTGRs

    International Nuclear Information System (INIS)

    Kunitomi, K.; Tachibana, Y.; Takeda, T.; Saikusa, A.; Shiozawa, S.

    1997-01-01

    Test programs of the High Temperature Engineering Test Reactor (HTTR) for future generation High Temperature Gas-Cooled Reactors (HTGRs) have been established considering design and development status of HTGRs in Japan and the world. Test programs are divided into six categories, thermal hydraulics, fuel, safety, high temperature components, core physics and control-instrumentations. All programs are related to the technology of future generation HTGRs and will be submitted to a new Coordinated Research Program (CRP) so that all participants from the world in test programs of the HTTR can use measured data for their future generation.HTGRs. This paper describes test programs of the HTTR for the development of future generation HTGRs after explanation of a future generation HTGR in Japan. (author)

  14. Automated test data generation for branch testing using incremental

    Indian Academy of Sciences (India)

    Cost of software testing can be reduced by automated test data generation to find a minimal set of data that has maximum coverage. Search-based software testing (SBST) is one of the techniques recently used for automated testing task. SBST makes use of control flow graph (CFG) and meta-heuristic search algorithms to ...

  15. A power scalable PLL frequency synthesizer for high-speed Δ—Σ ADC

    International Nuclear Information System (INIS)

    Han Siyang; Chi Baoyong; Zhang Xinwang; Wang Zhihua

    2014-01-01

    A 35–130 MHz/300–360 MHz phase-locked loop frequency synthesizer for Δ—Σ analog-to-digital converter (ADC) in 65 nm CMOS is presented. The frequency synthesizer can work in low phase-noise mode (300–360 MHz) or in low-power mode (35–130 MHz) to satisfy the ADC's requirements. To switch between these two modes, a high frequency GHz LC VCO followed by a divided-by-four frequency divider and a low frequency ring VCO followed by a divided-by-two frequency divider are integrated on-chip. The measured results show that the frequency synthesizer achieves a phase-noise of −132 dBc/Hz at 1 MHz offset and an integrated RMS jitter of 1.12 ps with 1.74 mW power consumption from a 1.2 V power supply in low phase-noise mode. In low-power mode, the frequency synthesizer achieves a phase-noise of −112 dBc/Hz at 1 MHz offset and an integrated RMS jitter of 7.23 ps with 0.92 mW power consumption from a 1.2 V power supply. (semiconductor integrated circuits)

  16. Test signal generation for analog circuits

    Directory of Open Access Journals (Sweden)

    B. Burdiek

    2003-01-01

    Full Text Available In this paper a new test signal generation approach for general analog circuits based on the variational calculus and modern control theory methods is presented. The computed transient test signals also called test stimuli are optimal with respect to the detection of a given fault set by means of a predefined merit functional representing a fault detection criterion. The test signal generation problem of finding optimal test stimuli detecting all faults form the fault set is formulated as an optimal control problem. The solution of the optimal control problem representing the test stimuli is computed using an optimization procedure. The optimization procedure is based on the necessary conditions for optimality like the maximum principle of Pontryagin and adjoint circuit equations.

  17. A fast ADC system for silicon μstrips readout

    International Nuclear Information System (INIS)

    Inzani, P.; Pedrini, D.; Sala, S.

    1986-01-01

    A new fast ADC module has been designed. It is part of a large readout system for a high resolution vertex detector consisting of 12 silicon microstrip planes with more than 8000 channels. The module employs a set of monolithic gated integrators on input (LeCroy MIQ 401) multiplexed on a single 8 bit FADC (Thompson EFX8308). A built-in preprocessing, performed through look up tables, accomplishes equalization and reduction of the data and makes high level trigger feasible. As an additional feature, fast histogramming of all the channels in parallel has been made possible with an internal memory. Special care has been paid to realize a low cost and low power consumption system

  18. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

  19. Atypical manifestations of reversible posterior leukoencephalopathy syndrome: findings on diffusion imaging and ADC mapping

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.J.; You, W.J.; Jeong, S.L.; Lee, J.W.; Kim, B.S.; Lee, J.H.; Hahn, S.T. [Dept. of Radiology, The Catholic Univ. of Korea, St. Mary' s Hospital, Seoul (Korea); Yang, D.W.; Son, Y.M. [Dept. of Neurology, The Catholic Univ. of Korea, St. Mary' s Hospital, Seoul (Korea)

    2004-12-01

    Typically, reversible posterior leukoencephalopathy syndrome (RPLS) involves the parieto-occipital lobes. When regions of the brain other than the parieto-occipital lobes are predominantly involved, the syndrome can be called atypical RPLS. The purpose of this study is to find radiological and pathophysiological features of atypical RPLS by using diffusion-weighted imaging (D-WI). We retrospectively reviewed seven patients (two with eclampsia, one with cyclosporine neurotoxicity, and four with hypertensive encephalopathy) with atypical MR manifestations of RPLS. Changes in signal intensity on T2-weighted imaging (T2-WI) and D-WI, and ADC ratio, were analyzed. In patients with atypical manifestation of RPLS, high signal intensities on T2-WI were noted in the frontal lobe, basal ganglia, thalamus, brainstem, and subcortical white matter in regions other than the parieto-occipital lobes. These areas of increased signal intensities on T2-WI showed increased ADC values, representing vasogenic edema in all seven patients. This result should be very useful in differentiating atypical RPLS from other metabolic brain disorders that affect the same sites with cytotoxic edema. (orig.)

  20. Atypical manifestations of reversible posterior leukoencephalopathy syndrome: findings on diffusion imaging and ADC mapping

    International Nuclear Information System (INIS)

    Ahn, K.J.; You, W.J.; Jeong, S.L.; Lee, J.W.; Kim, B.S.; Lee, J.H.; Hahn, S.T.; Yang, D.W.; Son, Y.M.

    2004-01-01

    Typically, reversible posterior leukoencephalopathy syndrome (RPLS) involves the parieto-occipital lobes. When regions of the brain other than the parieto-occipital lobes are predominantly involved, the syndrome can be called atypical RPLS. The purpose of this study is to find radiological and pathophysiological features of atypical RPLS by using diffusion-weighted imaging (D-WI). We retrospectively reviewed seven patients (two with eclampsia, one with cyclosporine neurotoxicity, and four with hypertensive encephalopathy) with atypical MR manifestations of RPLS. Changes in signal intensity on T2-weighted imaging (T2-WI) and D-WI, and ADC ratio, were analyzed. In patients with atypical manifestation of RPLS, high signal intensities on T2-WI were noted in the frontal lobe, basal ganglia, thalamus, brainstem, and subcortical white matter in regions other than the parieto-occipital lobes. These areas of increased signal intensities on T2-WI showed increased ADC values, representing vasogenic edema in all seven patients. This result should be very useful in differentiating atypical RPLS from other metabolic brain disorders that affect the same sites with cytotoxic edema. (orig.)

  1. A Whole-Tumor Histogram Analysis of Apparent Diffusion Coefficient Maps for Differentiating Thymic Carcinoma from Lymphoma.

    Science.gov (United States)

    Zhang, Wei; Zhou, Yue; Xu, Xiao-Quan; Kong, Ling-Yan; Xu, Hai; Yu, Tong-Fu; Shi, Hai-Bin; Feng, Qing

    2018-01-01

    To assess the performance of a whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in differentiating thymic carcinoma from lymphoma, and compare it with that of a commonly used hot-spot region-of-interest (ROI)-based ADC measurement. Diffusion weighted imaging data of 15 patients with thymic carcinoma and 13 patients with lymphoma were retrospectively collected and processed with a mono-exponential model. ADC measurements were performed by using a histogram-based and hot-spot-ROI-based approach. In the histogram-based approach, the following parameters were generated: mean ADC (ADC mean ), median ADC (ADC median ), 10th and 90th percentile of ADC (ADC 10 and ADC 90 ), kurtosis, and skewness. The difference in ADCs between thymic carcinoma and lymphoma was compared using a t test. Receiver operating characteristic analyses were conducted to determine and compare the differentiating performance of ADCs. Lymphoma demonstrated significantly lower ADC mean , ADC median , ADC 10 , ADC 90 , and hot-spot-ROI-based mean ADC than those found in thymic carcinoma (all p values histogram analysis of ADC maps can improve the differentiating performance between thymic carcinoma and lymphoma.

  2. Area-efficient readout with 14-bit SAR-ADC for CMOS image sensors

    Directory of Open Access Journals (Sweden)

    Aziza Sassi Ben

    2016-01-01

    Full Text Available This paper proposes a readout design for CMOS image sensors. It has been squeezed into a 7.5um pitch under a 0.28um 1P3M technology. The ADC performs one 14-bit conversion in only 1.5us and targets a theoretical DNL feature about +1.3/-1 at 14-bit accuracy. Correlated Double Sampling (CDS is performed both in the analog and digital domains to preserve the image quality.

  3. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0....... Correlations between mean ADC and EI and 15th percentile were both r=0.90 and for MLD r=0.59. There was higher correlation between mean ADC and %predicted DLCO (r=0.90) than between EI and %predicted DLCO (r=0.76). CONCLUSION: HP (3)He-MRI correlates well with density measurements from MSCT and agrees better...

  4. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    PURPOSE: To compare apparent diffusion coefficient (ADC) measurements from hyperpolarized (HP) helium ((3)He)-magnetic resonance imaging (MRI) with quantitative data from multislice Computed Tomography (CT) (MSCT) of the whole lungs and pulmonary function tests (PFT). MATERIALS AND METHODS: Twenty......-seven subjects, 22 with established emphysema and 5 with preclinical emphysema defined by PFT criteria, were examined with HP (3)He-MRI and MSCT. Mean age was 55 (+/-12) years, 18 female and 9 male. Mean ADC from (3)He-MRI was compared with emphysema index (EI), 15th percentile and mean lung density (MLD) values...... from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0...

  5. A 14-bit 30-MS/s 38-mW SAR ADC using noise filter gear shifting

    NARCIS (Netherlands)

    Kramer, Martin; Janssen, Erwin; Doris, Kostas; Murmann, Boris

    2017-01-01

    We present a successive approximation register analog-to-digital converter (ADC) that employs a comparator with time-varying noise performance, realized by changing the integration time of a Gm-C preamplifier. This approach allows us to relax precision and enhance speed during noncritical decisions,

  6. An 11b 3.6GS/s time-Iiterleaved SAR ADC in 65nm CMOS

    NARCIS (Netherlands)

    Janssen, E.J.G.; Doris, K.; Zanikopoulos, A.; Murroni, A.; Weide, van der G.; Lin, Y.; Alvado, L.; Darthenay, F.; Fregeais, Y.

    2013-01-01

    Over the last years several low-power time-interleaved (TI) ADC designs in the 2.5-to-3.0GS/s range have been published [1-3], intended for integration in applications like radar, software-defined radio, full-spectrum cable modems, and multi-channel satellite reception. It is to be expected that

  7. Model-Driven Test Generation of Distributed Systems

    Science.gov (United States)

    Easwaran, Arvind; Hall, Brendan; Schweiker, Kevin

    2012-01-01

    This report describes a novel test generation technique for distributed systems. Utilizing formal models and formal verification tools, spe cifically the Symbolic Analysis Laboratory (SAL) tool-suite from SRI, we present techniques to generate concurrent test vectors for distrib uted systems. These are initially explored within an informal test validation context and later extended to achieve full MC/DC coverage of the TTEthernet protocol operating within a system-centric context.

  8. The value of whole lesion ADC histogram profiling to differentiate between morphologically indistinguishable ring enhancing lesions–comparison of glioblastomas and brain abscesses

    Science.gov (United States)

    Hoffmann, Karl-Titus; Garnov, Nikita; Vörkel, Cathrin; Kohlhof-Meinecke, Patricia; Ganslandt, Oliver; Bäzner, Hansjörg; Gihr, Georg Alexander; Kalman, Marcell; Henkes, Elina; Henkes, Hans; Schob, Stefan

    2018-01-01

    Background Morphologically similar appearing ring enhancing lesions in the brain parenchyma can be caused by a number of distinct pathologies, however, they consistently represent life-threatening conditions. The two most frequently encountered diseases manifesting as such are glioblastoma multiforme (GBM) and brain abscess (BA), each requiring disparate therapeutical approaches. As a result of their morphological resemblance, essential treatment might be significantly delayed or even ommited, in case results of conventional imaging remain inconclusive. Therefore, our study aimed to investigate, whether ADC histogram profiling reliably can distinguish between both entities, thus enhancing the differential diagnostic process and preventing treatment failure in this highly critical context. Methods 103 patients (51 BA, 52 GBM) with histopathologically confirmed diagnosis were enrolled. Pretreatment diffusion weighted imaging (DWI) was obtained in a 1.5T system using b values of 0, 500, and 1000 s/mm2. Whole lesion ADC volumes were analyzed using a histogram-based approach. Statistical analysis was performed using SPSS version 23. Results All investigated parameters were statistically different in comparison of both groups. Most importantly, ADCp10 was able to differentiate reliably between BA and GBM with excellent accuracy (0.948) using a cutpoint value of 70 × 10−5 mm2 × s−1. Conclusions ADC whole lesion histogram profiling provides a valuable tool to differentiate between morphologically indistinguishable mass lesions. Among the investigated parameters, the 10th percentile of the ADC volume distinguished best between GBM and BA. PMID:29719596

  9. The value of whole lesion ADC histogram profiling to differentiate between morphologically indistinguishable ring enhancing lesions-comparison of glioblastomas and brain abscesses.

    Science.gov (United States)

    Horvath-Rizea, Diana; Surov, Alexey; Hoffmann, Karl-Titus; Garnov, Nikita; Vörkel, Cathrin; Kohlhof-Meinecke, Patricia; Ganslandt, Oliver; Bäzner, Hansjörg; Gihr, Georg Alexander; Kalman, Marcell; Henkes, Elina; Henkes, Hans; Schob, Stefan

    2018-04-06

    Morphologically similar appearing ring enhancing lesions in the brain parenchyma can be caused by a number of distinct pathologies, however, they consistently represent life-threatening conditions. The two most frequently encountered diseases manifesting as such are glioblastoma multiforme (GBM) and brain abscess (BA), each requiring disparate therapeutical approaches. As a result of their morphological resemblance, essential treatment might be significantly delayed or even ommited, in case results of conventional imaging remain inconclusive. Therefore, our study aimed to investigate, whether ADC histogram profiling reliably can distinguish between both entities, thus enhancing the differential diagnostic process and preventing treatment failure in this highly critical context. 103 patients (51 BA, 52 GBM) with histopathologically confirmed diagnosis were enrolled. Pretreatment diffusion weighted imaging (DWI) was obtained in a 1.5T system using b values of 0, 500, and 1000 s/mm 2 . Whole lesion ADC volumes were analyzed using a histogram-based approach. Statistical analysis was performed using SPSS version 23. All investigated parameters were statistically different in comparison of both groups. Most importantly, ADCp10 was able to differentiate reliably between BA and GBM with excellent accuracy (0.948) using a cutpoint value of 70 × 10 -5 mm 2 × s -1 . ADC whole lesion histogram profiling provides a valuable tool to differentiate between morphologically indistinguishable mass lesions. Among the investigated parameters, the 10th percentile of the ADC volume distinguished best between GBM and BA.

  10. With a 2k-ADC to 4k-spectrometry via two biased amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Goerner, W; Kleeberg, H [Zentralinstitut fuer Kernforschung, Rossendorf bei Dresden (German Democratic Republic)

    1978-01-12

    In order to obtain the double digital spread in high resolution nuclear spectrometry, two biased amplifiers were linked in parallel mode to the 10 V-input of a 2k-ADC. The arrangement works like a hybrid (1 bit scale - 11 bits Wilkinson) converter. A careful adjustment of the two bias levels (approximately 0V and approximately 6V) and the post-amplification (approximately 2) delivered a good linearity of the 4k-spectrum.

  11. Minimal-post-processing 320-Gbps true random bit generation using physical white chaos.

    Science.gov (United States)

    Wang, Anbang; Wang, Longsheng; Li, Pu; Wang, Yuncai

    2017-02-20

    Chaotic external-cavity semiconductor laser (ECL) is a promising entropy source for generation of high-speed physical random bits or digital keys. The rate and randomness is unfortunately limited by laser relaxation oscillation and external-cavity resonance, and is usually improved by complicated post processing. Here, we propose using a physical broadband white chaos generated by optical heterodyning of two ECLs as entropy source to construct high-speed random bit generation (RBG) with minimal post processing. The optical heterodyne chaos not only has a white spectrum without signature of relaxation oscillation and external-cavity resonance but also has a symmetric amplitude distribution. Thus, after quantization with a multi-bit analog-digital-convertor (ADC), random bits can be obtained by extracting several least significant bits (LSBs) without any other processing. In experiments, a white chaos with a 3-dB bandwidth of 16.7 GHz is generated. Its entropy rate is estimated as 16 Gbps by single-bit quantization which means a spectrum efficiency of 96%. With quantization using an 8-bit ADC, 320-Gbps physical RBG is achieved by directly extracting 4 LSBs at 80-GHz sampling rate.

  12. Validation test case generation based on safety analysis ontology

    International Nuclear Information System (INIS)

    Fan, Chin-Feng; Wang, Wen-Shing

    2012-01-01

    Highlights: ► Current practice in validation test case generation for nuclear system is mainly ad hoc. ► This study designs a systematic approach to generate validation test cases from a Safety Analysis Report. ► It is based on a domain-specific ontology. ► Test coverage criteria have been defined and satisfied. ► A computerized toolset has been implemented to assist the proposed approach. - Abstract: Validation tests in the current nuclear industry practice are typically performed in an ad hoc fashion. This study presents a systematic and objective method of generating validation test cases from a Safety Analysis Report (SAR). A domain-specific ontology was designed and used to mark up a SAR; relevant information was then extracted from the marked-up document for use in automatically generating validation test cases that satisfy the proposed test coverage criteria; namely, single parameter coverage, use case coverage, abnormal condition coverage, and scenario coverage. The novelty of this technique is its systematic rather than ad hoc test case generation from a SAR to achieve high test coverage.

  13. Test generation for digital circuits using parallel processing

    Science.gov (United States)

    Hartmann, Carlos R.; Ali, Akhtar-Uz-Zaman M.

    1990-12-01

    The problem of test generation for digital logic circuits is an NP-Hard problem. Recently, the availability of low cost, high performance parallel machines has spurred interest in developing fast parallel algorithms for computer-aided design and test. This report describes a method of applying a 15-valued logic system for digital logic circuit test vector generation in a parallel programming environment. A concept called fault site testing allows for test generation, in parallel, that targets more than one fault at a given location. The multi-valued logic system allows results obtained by distinct processors and/or processes to be merged by means of simple set intersections. A machine-independent description is given for the proposed algorithm.

  14. Performance of an automatic dose control system for CT. Specifications and basic phantom tests

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, H.D. [Wissenschaft und Technik fuer die Radiolgoe, Dr. HD Nagel, Buchholz (Germany); Stumpp, P.; Kahn, T.; Gosch, D. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2011-01-15

    Purpose: To assess the performance and to provide more detailed insight into the characteristics and limitations of devices for automatic dose control (ADC) in CT. Materials and Methods: A comprehensive study on DoseRight 2.0, the ADC system provided by Philips for its Brilliance CT scanners, was conducted. Phantom tests were carried out on a 64-slice scanner (Brilliance 64) using assorted quality control (QC) phantoms that allowed verification of the basic specifications. If feasible, the findings were verified by model calculations based on known specifications. Results: For all tests, the dose reductions and modulation characteristics fully met the values expected from the specifications. Adverse effects due to increased image noise were only moderate as a result of the 'adequate noise system' design that employs comparatively gentle modulation, and the additional use of adaptive filtration. Conclusion: Simple tests with QC phantoms allow evaluation of the most relevant characteristics of devices for ADC in CT. (orig.)

  15. Multifunction waveform generator for EM receiver testing

    Science.gov (United States)

    Chen, Kai; Jin, Sheng; Deng, Ming

    2018-01-01

    In many electromagnetic (EM) methods - such as magnetotelluric, spectral-induced polarization (SIP), time-domain-induced polarization (TDIP), and controlled-source audio magnetotelluric (CSAMT) methods - it is important to evaluate and test the EM receivers during their development stage. To assess the performance of the developed EM receivers, controlled synthetic data that simulate the observed signals in different modes are required. In CSAMT and SIP mode testing, the waveform generator should use the GPS time as the reference for repeating schedule. Based on our testing, the frequency range, frequency precision, and time synchronization of the currently available function waveform generators on the market are deficient. This paper presents a multifunction waveform generator with three waveforms: (1) a wideband, low-noise electromagnetic field signal to be used for magnetotelluric, audio-magnetotelluric, and long-period magnetotelluric studies; (2) a repeating frequency sweep square waveform for CSAMT and SIP studies; and (3) a positive-zero-negative-zero signal that contains primary and secondary fields for TDIP studies. In this paper, we provide the principles of the above three waveforms along with a hardware design for the generator. Furthermore, testing of the EM receiver was conducted with the waveform generator, and the results of the experiment were compared with those calculated from the simulation and theory in the frequency band of interest.

  16. The testing of generator circuit-breakers

    NARCIS (Netherlands)

    Smeets, R.P.P.; Linden, van der W.A.

    1998-01-01

    Generator circuit-breakers face much higher current and voltage stress than distribution switchgear. This has led to a special standard (ANSI C37.013). Strictly in accordance with this standard's requirements, test circuits and parameters for a 100 kA and 120 kA (25.3 kV) SF6 generator

  17. Test generator development for differential equations for lms moodle

    Directory of Open Access Journals (Sweden)

    Анна Александровна Муханова

    2014-12-01

    Full Text Available This article discusses the basic mechanisms of the test generator for differential equations, developed by the authors. The generator is designed to generate a large number of test questions in accordance with user-defined rules, which include: the number of tasks required for each type of differential equation, and the tasks difficulty, controlled by the nesting level of recursive functions. The generator produces a test file format GIFT, which is a plain text file.

  18. A low-voltage low-power 10-bit 200 MS/s pipelined ADC in 90 nm CMOS

    NARCIS (Netherlands)

    Abdinia, S.; Yavari, M.

    2010-01-01

    This paper presents a low-power 10-bit 200 MS/s pipelined ADC in a 90 nm CMOS technology with 1 V supply voltage. To decrease the power dissipation efficiently, a new architecture using a combination of two power reduction techniques named double-sampling and opamp-sharing has been used to reduce

  19. Random number generators tested on quantum Monte Carlo simulations.

    Science.gov (United States)

    Hongo, Kenta; Maezono, Ryo; Miura, Kenichi

    2010-08-01

    We have tested and compared several (pseudo) random number generators (RNGs) applied to a practical application, ground state energy calculations of molecules using variational and diffusion Monte Carlo metheds. A new multiple recursive generator with 8th-order recursion (MRG8) and the Mersenne twister generator (MT19937) are tested and compared with the RANLUX generator with five luxury levels (RANLUX-[0-4]). Both MRG8 and MT19937 are proven to give the same total energy as that evaluated with RANLUX-4 (highest luxury level) within the statistical error bars with less computational cost to generate the sequence. We also tested the notorious implementation of linear congruential generator (LCG), RANDU, for comparison. (c) 2010 Wiley Periodicals, Inc.

  20. Custom pulse generator for RPC testing

    International Nuclear Information System (INIS)

    Gil, A.; Castro, E.; Diaz, J.; Fonte, P.; Garzon, J.A.; Montes, N.; Zapata, M.

    2009-01-01

    We present a pulse generator able to generate pulses statistically similar to the ones produced by RPC cells. The device generates up to four arrays of fast and narrow random-like pulses. Polarity, maximum amplitudes, widths and pulse rate in each channel may be modified independently in order to simulate different RPC setups and environments. This portable and cost-effective pulse generator is a versatile instrument for testing FE-Electronics and different real detector features related with the signal propagation inside the detector. It has been developed in the framework of the ESTRELA project of the HADES experiment at GSI.

  1. On the design of high-speed energy-efficient successive-approximation logic for asynchronous SAR ADCs

    Science.gov (United States)

    Yang, Jiaqi; Li, Ting; Yu, Mingyuan; Zhang, Shuangshuang; Lin, Fujiang; He, Lin

    2017-08-01

    This paper analyzes the power consumption and delay mechanisms of the successive-approximation (SA) logic of a typical asynchronous SAR ADC, and provides strategies to reduce both of them. Following these strategies, a unique direct-pass SA logic is proposed based on a full-swing once-triggered DFF and a self-locking tri-state gate. The unnecessary internal switching power of a typical TSPC DFF, which is commonly used in the SA logic, is avoided. The delay of the ready detector as well as the sequencer is removed from the critical path. A prototype SAR ADC based on the proposed SA logic is fabricated in 130 nm CMOS. It achieves a peak SNDR of 56.3 dB at 1.2 V supply and 65 MS/s sampling rate, and has a total power consumption of 555 μW, while the digital part consumes only 203 μW. Project supported by the National Natural Science Foundation of China (Nos. 61204033, 61331015), the Fundamental Research Funds for the Central Universities (No. WK2100230015), and the Funds of Science and Technology on Analog Integrated Circuit Laboratory (No. 9140C090111150C09041).

  2. Attitude Determination and Control Subsystem (ADCS) Preparations for the EPOXI Flyby of Comet Haley 2

    Science.gov (United States)

    Luna, Michael E.; Collins, Stephen M.

    2011-01-01

    On November 4, 2010 the already "in-flight" Deep Impact spacecraft flew within 700km of comet 103P/Hartley 2 as part of its extended mission EPOXI, the 5th time to date any spacecraft visited a comet. In 2005, the spacecraft had previously imaged a probe impact comet Tempel 1. The EPOXI flyby marked the first time in history that two comets were explored with the same instruments on a re-used spacecraft-with hardware and software originally designed and optimized for a different mission. This made the function of the attitude determination and control subsystem (ADCS) critical to the successful execution of the EPOXI flyby. As part of the spacecraft team preparations, the ADCS team had to perform thorough sequence reviews, key spacecraft activities and onboard calibrations. These activities included: review of background sequences for the initial conditions vector, sun sensor coefficients, and reaction wheel assembly (RWA) de-saturations; design and execution of 10 trajectory correction maneuvers; science calibration of the two telescope instruments; a flight demonstration of the fastest turns conducted by the spacecraft between Earth and comet point; and assessment of RWA health (given RWA problems on other spacecraft).

  3. Testing of a direct drive generator for wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Sondergaard, L.M. [Riso National Laboratory, Roskilde (Denmark)

    1996-12-31

    The normal drive train of a wind turbine consists a gearbox and a 4 to 8 poles asynchronous generator. The gearbox is an expensive and unreliable components and this paper deals with testing of a direct drive synchronous generator for a gearless wind turbine. The Danish company Belt Electric has constructed and manufactured a 27 kW prototype radial flux PM-generator (DD600). They have used cheap hard ferrite magnets in the rotor of this PM-generator. This generator has been tested at Riso and the test results are investigated and analyzed in this paper. The tests have been done with three different load types (1: resistance; 2: diode rectifier, DC-capacitor, resistance; 3: AC-capacitor, diode rectifier, DC-capacitor, resistance). 1 ref., 9 figs., 5 tabs.

  4. An UI Layout Files Analyzer for Test Data Generation

    Directory of Open Access Journals (Sweden)

    Paul POCATILU

    2014-01-01

    Full Text Available Prevention actions (trainings, audits and inspections (tests, validations, code reviews are the crucial factors in achieving a high quality level for any software application simply because low investments in this area are leading to significant expenses in terms of corrective actions needed for defect fixing. Mobile applications testing involves the use of various tools and scenarios. An important process is represented by test data generation. This paper proposes a test data generator (TDG system for mobile applications using several sources for test data and it focuses on the UI layout files analyzer module. The proposed architecture aims to reduce time-to-market for mobile applications. The focus is on test data generators based on the source code, user interface layout files (using markup languages like XML or XAML and application specifications. In order to assure a common interface for test data generators, an XML or JSON-based language called Data Specification Language (DSL is proposed.

  5. Design and Optimization of Multi-bit Front-end Stage and Scaled Back-end Stages of Pipelined ADCs

    NARCIS (Netherlands)

    Quinn, P.J.; Roermund, van A.H.M.

    2005-01-01

    In this paper, an error analysis is presented to aid the design of a pipeline multi-bit front-end stage. It is demonstrated and quantified how the capacitor matching requirement can be reduced in high-resolution pipeline ADCs. The paper continues by analyzing the optimal design for low power of the

  6. Solid-state mAbs and ADCs subjected to heat-stress stability conditions can be covalently modified with buffer and excipient molecules.

    Science.gov (United States)

    Valliere-Douglass, John F; Lewis, Patsy; Salas-Solano, Oscar; Jiang, Shan

    2015-02-01

    We report that a unique type of chemical modification occurs on lyophilized proteins. Freeze-dried mAbs and antibody-drug conjugates (ADCs) can be covalently modified with buffer and excipient molecules on the side chains of Glu, Asp, Thr, and Ser amino acids when subjected to temperature stress. The reaction occurs primarily via condensation of common buffers and excipients such as histidine, tris, trehalose and sucrose, with Glu and Asp carboxylates in the primary sequence of proteins. The reaction was also found to proceed through condensation of carboxylate containing buffers such as citrate, with Thr and Ser hydroxyls in the primary sequence of proteins. Based on the mass of the covalent adducts observed on mAbs and ADCs, it is apparent that the reaction produces water as a product and is thus favored in a low moisture environments such as a lyophilized protein cake. Herein, we present the evidence for the covalent modification of proteins drawn from case studies of in-depth characterization of heat-stressed mAbs and ADCs in the solid state. We also demonstrate how common charge variant assays such as imaged capillary isoelectric focusing and mass spectrometry can be used to monitor this specific class of protein modification. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  7. Free-running ADC- and FPGA-based signal processing method for brain PET using GAPD arrays

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Wei [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Choi, Yong, E-mail: ychoi.image@gmail.com [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Hong, Key Jo [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Kang, Jihoon [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Jung, Jin Ho [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Huh, Youn Suk [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Lim, Hyun Keong; Kim, Sang Su [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Kim, Byung-Tae [Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Chung, Yonghyun [Department of Radiological Science, Yonsei University College of Health Science, 234 Meaji, Heungup Wonju, Kangwon-Do 220-710 (Korea, Republic of)

    2012-02-01

    Currently, for most photomultiplier tube (PMT)-based PET systems, constant fraction discriminators (CFD) and time to digital converters (TDC) have been employed to detect gamma ray signal arrival time, whereas anger logic circuits and peak detection analog-to-digital converters (ADCs) have been implemented to acquire position and energy information of detected events. As compared to PMT the Geiger-mode avalanche photodiodes (GAPDs) have a variety of advantages, such as compactness, low bias voltage requirement and MRI compatibility. Furthermore, the individual read-out method using a GAPD array coupled 1:1 with an array scintillator can provide better image uniformity than can be achieved using PMT and anger logic circuits. Recently, a brain PET using 72 GAPD arrays (4 Multiplication-Sign 4 array, pixel size: 3 mm Multiplication-Sign 3 mm) coupled 1:1 with LYSO scintillators (4 Multiplication-Sign 4 array, pixel size: 3 mm Multiplication-Sign 3 mm Multiplication-Sign 20 mm) has been developed for simultaneous PET/MRI imaging in our laboratory. Eighteen 64:1 position decoder circuits (PDCs) were used to reduce GAPD channel number and three off-the-shelf free-running ADC and field programmable gate array (FPGA) combined data acquisition (DAQ) cards were used for data acquisition and processing. In this study, a free-running ADC- and FPGA-based signal processing method was developed for the detection of gamma ray signal arrival time, energy and position information all together for each GAPD channel. For the method developed herein, three DAQ cards continuously acquired 18 channels of pre-amplified analog gamma ray signals and 108-bit digital addresses from 18 PDCs. In the FPGA, the digitized gamma ray pulses and digital addresses were processed to generate data packages containing pulse arrival time, baseline value, energy value and GAPD channel ID. Finally, these data packages were saved to a 128 Mbyte on-board synchronous dynamic random access memory (SDRAM) and

  8. Enhancing SAT-Based Test Pattern Generation

    Institute of Scientific and Technical Information of China (English)

    LIU Xin; XIONG You-lun

    2005-01-01

    This paper presents modeling tools based on Boolean satisfiability (SAT) to solve problems of test generation for combinational circuits. It exploits an added layer to maintain circuit-related information and value justification relations to a generic SAT algorithm. It dovetails binary decision graphs (BDD) and SAT techniques to improve the efficiency of automatic test pattern generation (ATPG). More specifically, it first exploits inexpensive reconvergent fanout analysis of circuit to gather information on the local signal correlation by using BDD learning, then uses the above learned information to restrict and focus the overall search space of SAT-based ATPG. Its learning technique is effective and lightweight. The experimental results demonstrate the effectiveness of the approach.

  9. A Repetition Test for Pseudo-Random Number Generators

    OpenAIRE

    Gil, Manuel; Gonnet, Gaston H.; Petersen, Wesley P.

    2017-01-01

    A new statistical test for uniform pseudo-random number generators (PRNGs) is presented. The idea is that a sequence of pseudo-random numbers should have numbers reappear with a certain probability. The expectation time that a repetition occurs provides the metric for the test. For linear congruential generators (LCGs) failure can be shown theoretically. Empirical test results for a number of commonly used PRNGs are reported, showing that some PRNGs considered to have good statistical propert...

  10. Experimental demonstration of a real-time high-throughput digital DC blocker for compensating ADC imperfections in optical fast-OFDM receivers.

    Science.gov (United States)

    Zhang, Lu; Ouyang, Xing; Shao, Xiaopeng; Zhao, Jian

    2016-06-27

    Performance degradation induced by the DC components at the output of real-time analogue-to-digital converter (ADC) is experimentally investigated for optical fast-OFDM receiver. To compensate this degradation, register transfer level (RTL) circuits for real-time digital DC blocker with 20GS/s throughput are proposed and implemented in field programmable gate array (FPGA). The performance of the proposed real-time digital DC blocker is experimentally investigated in a 15Gb/s optical fast-OFDM system with intensity modulation and direct detection over 40 km standard single-mode fibre. The results show that the fixed-point DC blocker has negligible performance penalty compared to the offline floating point one, and can overcome the error floor of the fast OFDM receiver caused by the DC components from the real-time ADC output.

  11. Model Based Analysis and Test Generation for Flight Software

    Science.gov (United States)

    Pasareanu, Corina S.; Schumann, Johann M.; Mehlitz, Peter C.; Lowry, Mike R.; Karsai, Gabor; Nine, Harmon; Neema, Sandeep

    2009-01-01

    We describe a framework for model-based analysis and test case generation in the context of a heterogeneous model-based development paradigm that uses and combines Math- Works and UML 2.0 models and the associated code generation tools. This paradigm poses novel challenges to analysis and test case generation that, to the best of our knowledge, have not been addressed before. The framework is based on a common intermediate representation for different modeling formalisms and leverages and extends model checking and symbolic execution tools for model analysis and test case generation, respectively. We discuss the application of our framework to software models for a NASA flight mission.

  12. Test results of sodium-water reaction testing in near prototypical LMR steam generator

    International Nuclear Information System (INIS)

    Boardman, C.E.; Hui, M.; Neely, H.H.

    1990-01-01

    An extensive test program has been performed in the United States to investigate the effects of large sodium-water reaction events in LMFBR steam generators. Tests were conducted in the Large Leak Test Rig (LLTR) located at the Energy Technology Engineering Center (ETEC). The program was divided into two phases, Series I and Series II, for the purpose of satisfying near-term and long-term needs. Series II was further subdivided into large and intermediate leak tests. This paper will emphasize the Series II intermediate leak tests and resulting conclusions for steam generator design and operation. 11 figs, 2 tabs

  13. Generation speed in Raven's Progressive Matrices Test

    NARCIS (Netherlands)

    Verguts, T.; Boeck, P. De; Maris, E.G.G.

    1999-01-01

    In this paper, we investigate the role of response fluency on a well-known intelligence test, Raven's (1962) Advanced Progressive Matrices (APM) test. Critical in solving this test is finding rules that govern the items. Response fluency is conceptualized as generation speed or the speed at which a

  14. Fueled viking generator S/N 106 acceptance vibration test report

    International Nuclear Information System (INIS)

    Anderson, C.; Brewer, C.O.; Abrahamson, S.G.

    1976-01-01

    The Viking Generator S/N 106 was vibrated to the Teledyne Isotope Flight Acceptance Schedule (Random Only) with no deviation from normal generator functional output. Radiographic analysis and power tests before and after the vibration test indicated no change in the condition of the generator. The work was conducted in the Alpha Fuels Environmental Test Facility at Mound Laboratory

  15. Design and Simulation of a 6-Bit Successive-Approximation ADC Using Modeled Organic Thin-Film Transistors

    Directory of Open Access Journals (Sweden)

    Huyen Thanh Pham

    2016-01-01

    Full Text Available We have demonstrated a method for using proper models of pentacene P-channel and fullerene N-channel thin-film transistors (TFTs in order to design and simulate organic integrated circuits. Initially, the transistors were fabricated, and we measured their main physical and electrical parameters. Then, these organic TFTs (OTFTs were modeled with support of an organic process design kit (OPDK added in Cadence. The key specifications of the modeled elements were extracted from measured data, whereas the fitting ones were elected to replicate experimental curves. The simulating process proves that frequency responses of the TFTs cover all biosignal frequency ranges; hence, it is reasonable to deploy the elements to design integrated circuits used in biomedical applications. Complying with complementary rules, the organic circuits work properly, including logic gates, flip-flops, comparators, and analog-to-digital converters (ADCs as well. The proposed successive-approximation-register (SAR ADC consumes a power of 883.7 µW and achieves an ENOB of 5.05 bits, a SNR of 32.17 dB at a supply voltage of 10 V, and a sampling frequency of about 2 KHz.

  16. Diesel generator trailer acceptance test procedure

    International Nuclear Information System (INIS)

    Kostelnik, A.J.

    1994-01-01

    This Acceptance Test Procedure (ATP) will document compliance with the requirements of WHC-S-0252 Rev. 1 and ECNs 609271, and 609272. The equipment being tested is a 150KW Diesel Generator mounted on a trailer with switchgear. The unit was purchased as a Design and Fabrication procurement activity. The ATP was written by the Seller and will be performed by the Seller with representatives of the Westinghouse Hanford Company witnessing the test at the Seller's location

  17. An Optimization-Based Reconfigurable Design for a 6-Bit 11-MHz Parallel Pipeline ADC with Double-Sampling S&H

    Directory of Open Access Journals (Sweden)

    Wilmar Carvajal

    2012-01-01

    Full Text Available This paper presents a 6 bit, 11 MS/s time-interleaved pipeline A/D converter design. The specification process, from block level to elementary circuits, is gradually covered to draw a design methodology. Both power consumption and mismatch between the parallel chain elements are intended to be reduced by using some techniques such as double and bottom-plate sampling, fully differential circuits, RSD digital correction, and geometric programming (GP optimization of the elementary analog circuits (OTAs and comparators design. Prelayout simulations of the complete ADC are presented to characterize the designed converter, which consumes 12 mW while sampling a 500 kHz input signal. Moreover, the block inside the ADC with the most stringent requirements in power, speed, and precision was sent to fabrication in a CMOS 0.35 μm AMS technology, and some postlayout results are shown.

  18. [Characteristics of high resolution diffusion weighted imaging apparent diffusion coefficient histogram and its correlations with cancer stages in patients with nasopharyngeal carcinoma].

    Science.gov (United States)

    Wang, G J; Wang, Y; Ye, Y; Chen, F; Lu, Y T; Li, S L

    2017-11-07

    Objective: To investigate the features of apparent diffusion coefficient (ADC) histogram parameters based on entire tumor volume data in high resolution diffusion weighted imaging of nasopharyngeal carcinoma (NPC) and to evaluate its correlations with cancer stages. Methods: This retrospective study included 154 cases of NPC patients[102 males and 52 females, mean age (48±11) years]who had received readout segmentation of long variable echo trains of MRI scan before radiation therapy. The area of tumor was delineated on each section of axial ADC maps to generate ADC histogram by using Image J. ADC histogram of entire tumor along with the histogram parameters-the tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness and kurtosis were obtained by merging all sections with SPSS 22.0 software. Intra-observer repeatability was assessed by using intra-class correlation coefficients (ICC). The patients were subdivided into two groups according to cancer volume: small cancer group (histogram parameters and cancer stages was evaluated with Spearman test. Results: The ICC of measuring ADC histogram parameters of tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness, kurtosis was 0.938, 0.861, 0.885, 0.838, 0.836, 0.358 and 0.456, respectively. The tumor voxels was positively correlated with T staging ( r =0.368, P histogram (ADC(mean), ADC(25%), ADC(50%)) increases with T staging in NPC smaller than 2 cm(3).

  19. A channel multiplexing for the analog input channel of the advantech PCL-718 ADC-12 bit by using PCLD-889 programmable ampliplexer / multiplexer board have been done

    International Nuclear Information System (INIS)

    Sudiyanto; Aminus, S; Sujono, Djoko; Ngatinu; Sudaryanto; Wiyana, Badi

    1996-01-01

    A channel multiplexing for the analog input channels of the Advantech PCL-718 ADC-12 bit by using PCLD-889 programmable Amplifier / multiplexer board have been done. The experiments have been prepared by using Turbo-C software where every PCLD-889 board multiplexes 16 differential input channels into one analog output channel, up to 10 PCLD-889 can be cascaded to expand the analog input of PCL-718 ADC-12 bit to 8 x 16 channels

  20. Operating experience of steam generator test facility

    International Nuclear Information System (INIS)

    Sureshkumar, V.A.; Madhusoodhanan, G.; Noushad, I.B.; Ellappan, T.R.; Nashine, B.K.; Sylvia, J.I.; Rajan, K.K.; Kalyanasundaram, P.; Vaidyanathan, G.

    2006-01-01

    Steam Generator (SG) is the vital component of a Fast Reactor. It houses both water at high pressure and sodium at low pressure separated by a tube wall. Any damage to this barrier initiates sodium water reaction that could badly affect the plant availability. Steam Generator Test Facility (SGTF) has been set up in Indira Gandhi Centre for Atomic Research (IGCAR) to test sodium heated once through steam generator of 19 tubes similar to the PFBR SG dimension and operating conditions. The facility is also planned as a test bed to assess improved designs of the auxiliary equipments used in Fast Breeder Reactors (FBR). The maximum power of the facility is 5.7 MWt. This rating is arrived at based on techno economic consideration. This paper covers the performance of various equipments in the system such as Electro magnetic pumps, Centrifugal sodium pump, in-sodium hydrogen meters, immersion heaters, and instrumentation and control systems. Experience in the system operation, minor modifications, overall safety performance, and highlights of the experiments carried out etc. are also brought out. (author)

  1. Completing the series. New coordination networks of composition {sup 3}{sub ∞}[RE{sub 2}(ADC){sub 3}(H{sub 2}O){sub 6}].2H{sub 2}O with RE = Pr, Nd, Sm, Eu, Tb, Dy, Ho, Er, Y and ADC{sup 2-} = acetylenedicarboxylate ({sup -}O{sub 2}C-C≡C-CO{sub 2}{sup -})

    Energy Technology Data Exchange (ETDEWEB)

    Gramm, Verena K.; Schuy, Andrea; Ruschewitz, Uwe [Institut fuer Anorganische Chemie, Koeln Univ. (Germany); Suta, Markus; Wickleder, Claudia [Anorganische Chemie, Universitaet Siegen (Germany); Sternemann, Christian [Fakultaet Physik / DELTA, Technische Universitaet Dortmund (Germany)

    2018-02-01

    The crystal structures of {sup 3}{sub ∞}[RE{sub 2}(ADC){sub 3}(H{sub 2}O){sub 6}].2H{sub 2}O (RE = Pr, Nd, Sm, Eu, Tb, Dy) were solved and refined from X-ray single crystal data. They crystallize in a structure type already known for RE = La, Ce and Gd (P1, no. 2, Z = 2), which is characterized by REO{sub 9} polyhedra forming dimeric units being the nodes of a 3D framework structure linked by ADC{sup 2-} anions ({sup -}O{sub 2}C-C≡C-CO{sub 2}{sup -} = acetylenedicarboxylate). From synchrotron powder diffraction data it was shown that isostructural coordination networks are formed for RE = Ho, Er, Y, whereas for RE = Tm, Yb, Lu a new structure type crystallizing in a highly complex crystal structure with a large orthorhombic unit cell is found. All compounds are obtained by slow evaporation of an aqueous solution containing RE(OAc){sub 3}.xH{sub 2}O and acetylenedicarboxylic acid (H{sub 2}ADC). The coordination networks of composition {sup 3}{sub ∞}[RE{sub 2}(ADC){sub 3}(H{sub 2}O){sub 6}].2H{sub 2}O were thoroughly investigated by thermal analysis and for RE = Eu, Tb, a strong red and green photoluminescence was observed and investigated by means of UV/Vis spectroscopy. (copyright 2018 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. CAMAC based Test Signal Generator using Re-configurable device

    International Nuclear Information System (INIS)

    Sharma, Atish; Raval, Tushar; Srivastava, Amit K; Reddy, D Chenna

    2010-01-01

    There are many different types of signal generators, with different purposes and applications (and at varying levels of expense). In general, no device is suitable for all possible applications. Hence the selection of signal generator is as per requirements. For SST-1 Data Acquisition System requirements, we have developed a CAMAC based Test Signal Generator module using Re-configurable device (CPLD). This module is based on CAMAC interface but can be used for testing both CAMAC and PXI Data Acquisition Systems in SST-1 tokamak. It can also be used for other similar applications. Unlike traditional signal generators, which are embedded hardware, it is a flexible hardware unit, programmable through Graphical User Interface (GUI) developed in LabVIEW application development tool. The main aim of this work is to develop a signal generator for testing our data acquisition interface for a large number of channels simultaneously. The module front panel has various connectors like LEMO and D type connectors for signal interface. The module can be operated either in continuous signal generation mode or in triggered mode depending upon application. This can be done either by front panel switch or through CAMAC software commands (for remote operation). Similarly module reset and trigger generation operation can be performed either through front panel push button switch or through software CAMAC commands. The module has the facility to accept external TTL level trigger and clock through LEMO connectors. The module can also generate trigger and the clock signal, which can be delivered to other devices through LEMO connectors. The module generates two types of signals: Analog and digital (TTL level). The analog output (single channel) is generated from Digital to Analog Converter through CPLD for various types of waveforms like Sine, Square, Triangular and other wave shape that can vary in amplitude as well as in frequency. The module is quite useful to test up to 32 channels

  3. Pulse oximeter improvement with an ADC-DAC feedback loop and a radial reflectance sensor.

    Science.gov (United States)

    Thompson, David; Wareing, Austin; Day, Dwight; Warren, Steve

    2006-01-01

    Pulse oximeter circuitry must meet several design constraints, including the ability to separate a small pulsatile signal component from a large signal baseline. This paper describes pulse oximeter design changes that produced order-of-magnitude improvements in signal quality. The primary changes were (a) the replacement of an analog sample-and-hold-based differentiator circuit with an ADC-DAC feedback loop and (b) the replacement of a side-by-side reflectance sensor design with a radial sensor arrangement that maximizes the pulsatile-to-baseline signal ratio.

  4. Evaluating the Psychometric Characteristics of Generated Multiple-Choice Test Items

    Science.gov (United States)

    Gierl, Mark J.; Lai, Hollis; Pugh, Debra; Touchie, Claire; Boulais, André-Philippe; De Champlain, André

    2016-01-01

    Item development is a time- and resource-intensive process. Automatic item generation integrates cognitive modeling with computer technology to systematically generate test items. To date, however, items generated using cognitive modeling procedures have received limited use in operational testing situations. As a result, the psychometric…

  5. Test data generation for LRU cache-memory testing

    OpenAIRE

    Evgeni, Kornikhin

    2009-01-01

    System functional testing of microprocessors deals with many assembly programs of given behavior. The paper proposes new constraint-based algorithm of initial cache-memory contents generation for given behavior of assembly program (with cache misses and hits). Although algorithm works for any types of cache-memory, the paper describes algorithm in detail for basis types of cache-memory only: fully associative cache and direct mapped cache.

  6. Testing, Selection, and Implementation of Random Number Generators

    National Research Council Canada - National Science Library

    Collins, Joseph C

    2008-01-01

    An exhaustive evaluation of state-of-the-art random number generators with several well-known suites of tests provides the basis for selection of suitable random number generators for use in stochastic simulations...

  7. A pseudo-random number generator and its spectral test

    International Nuclear Information System (INIS)

    Wang Lai

    1998-01-01

    The author introduces a pseudo-random number generator and describes its algorithm and C language implementation. The performance of the generator is tested and compared with some well known LCG generators

  8. Using automatic item generation to create multiple-choice test items.

    Science.gov (United States)

    Gierl, Mark J; Lai, Hollis; Turner, Simon R

    2012-08-01

    Many tests of medical knowledge, from the undergraduate level to the level of certification and licensure, contain multiple-choice items. Although these are efficient in measuring examinees' knowledge and skills across diverse content areas, multiple-choice items are time-consuming and expensive to create. Changes in student assessment brought about by new forms of computer-based testing have created the demand for large numbers of multiple-choice items. Our current approaches to item development cannot meet this demand. We present a methodology for developing multiple-choice items based on automatic item generation (AIG) concepts and procedures. We describe a three-stage approach to AIG and we illustrate this approach by generating multiple-choice items for a medical licensure test in the content area of surgery. To generate multiple-choice items, our method requires a three-stage process. Firstly, a cognitive model is created by content specialists. Secondly, item models are developed using the content from the cognitive model. Thirdly, items are generated from the item models using computer software. Using this methodology, we generated 1248 multiple-choice items from one item model. Automatic item generation is a process that involves using models to generate items using computer technology. With our method, content specialists identify and structure the content for the test items, and computer technology systematically combines the content to generate new test items. By combining these outcomes, items can be generated automatically. © Blackwell Publishing Ltd 2012.

  9. Coincident steam generator tube rupture and stuck-open safety relief valve carryover tests: MB-2 steam generator transient response test program

    International Nuclear Information System (INIS)

    Garbett, K.; Mendler, O.J.; Gardner, G.C.; Garnsey, R.; Young, M.Y.

    1987-03-01

    In PWR steam generator tube rupture (SGTR) faults, a direct pathway for the release of radioactive fission products can exist if there is a coincident stuck-open safety relief valve (SORV) or if the safety relief valve is cycled. In addition to the release of fission products from the bulk steam generator water by moisture carryover, there exists the possibility that some primary coolant may be released without having first mixed with the bulk water - a process called primary coolant bypassing. The MB-2 Phase II test program was designed specifically to identify the processes for droplet carryover during SGTR faults and to provide data of sufficient accuracy for use in developing physical models and computer codes to describe activity release. The test program consisted of sixteen separate tests designed to cover a range of steady-state and transient fault conditions. These included a full SGTR/SORV transient simulation, two SGTR overfill tests, ten steady-state SGTR tests at water levels ranging from very low levels in the bundle up to those when the dryer was flooded, and three moisture carryover tests without SGTR. In these tests the influence of break location and the effect of bypassing the dryer were also studied. In a final test the behavior with respect to aerosol particles in a dry steam generator, appropriate to a severe accident fault, was investigated

  10. Generating an Automated Test Suite by Variable Strength Combinatorial Testing for Web Services

    Directory of Open Access Journals (Sweden)

    Yin Li

    2016-09-01

    Full Text Available Testing Web Services has become the spotlight of software engineering as an important means to assure the quality of Web application. Due to lacking of graphic interface and source code, Web services need an automated testing method, which is an important part in efficiently designing and generating test suite. However, the existing testing methods may lead to the redundancy of test suite and the decrease of fault-detecting ability since it cannot handle scenarios where the strengths of the different interactions are not uniform. With the purpose of solving this problem, firstly the formal tree model based on WSDL is constructed and the actual interaction relationship of each node is made sufficient consideration into, then the combinatorial testing is proposed to generate variable strength combinatorial test suite based on One-test-at-a-time strategy. At last test cases are minimized according to constraint rules. The results show that compared with conventional random testing, the proposed approach can detect more errors with the same amount of test cases which turning out to be more ideal than existing ones in size.

  11. Progression of emphysema in a 12-month hyperpolarized 3He-MRI study: lacunarity analysis provided a more sensitive measure than standard ADC analysis

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2009-01-01

    RATIONALE AND OBJECTIVES: Inhaled hyperpolarized (3)He magnetic resonance (MR) imaging has been used to measure alveolar size in patients with emphysema. The aim of this study was to test the hypothesis that (3)He MR images could be used to develop a biomarker of emphysema progression. MATERIALS...... AND METHODS: Twelve healthy controls and 18 patients with emphysema (eight current smokers, 10 ex-smokers) were imaged at baseline and 6 and 12 months. An additional nine subjects with alpha-1 antitrypsin deficiency (four with emphysema, six without symptoms) were also imaged at baseline and at 6 months. Each...... subject was imaged at two lung volumes: functional residual capacity (FRC) and FRC plus 15% of total lung capacity. Means and standard deviations of apparent diffusion coefficients (ADCs) were calculated from coronal images of the entire lung and correlated with pulmonary function test results...

  12. Test-retest reliability of diffusion tensor imaging of the liver at 3.0 T.

    Science.gov (United States)

    Girometti, Rossano; Maieron, Marta; Lissandrello, Giovanni; Bazzocchi, Massimo; Zuiani, Chiara

    2015-06-01

    This study was done to evaluate test-retest reliability of liver diffusion tensor imaging (LDTI). Ten healthy volunteers (median age 23 years) underwent two LDTI scans on a 3.0 T magnet during two imaging sessions separated by 2 weeks (session-1/-2, respectively). Fifteen gradient directions and b values of 0-1,000 s/mm(2) were used. Two radiologists in consensus assessed liver apparent diffusion coefficient (ADC) and fraction of anisotropy (FA) values on ADC and FA maps at four reference levels, namely: right upper level (RUL), right lower level (RLL), left upper level (LUL) and left lower level (LLL). We then assessed (a) whether ADC and FA values overlapped when measured on different levels within the same imaging session or between different imaging sessions; (b) the degree of variability on an intra-session and inter-session basis, respectively, using the coefficient of variation (CV). In sessions 1 and 2, the ADC/FA values were significantly larger in the left liver lobe (LUL/LLL) compared to right liver lobe (RUL/RLL) (p < 0.05/6). Intra-session CVs were 9.51 % (session 1) and 9.73 % (session 2) for ADC, and 12.93 % (session 1) and 11.82 % (session 2) for FA, respectively. When comparing RUL, RLL, LUL and LLL on an inter-session basis, CVs were 6.52, 8.20, 6.52 and 11.06 % for ADC, and 15.42, 15.80, 15.42 and 6.80 % for FA, respectively. LDTI provides consistent and repeatable measurements. However, since larger left lobe ADC/FA values can be attributed to artefacts, right lobe values should be considered the most reliable measurements of water diffusivity within the liver.

  13. Test of EMG-720 explosive magneto-cumulative generator

    Energy Technology Data Exchange (ETDEWEB)

    Popkov, N F; Pikar, A S; Ryaslov, E A [All-Russian Research Inst. of Experimental Physics, Sarov (Russian Federation); and others

    1997-12-31

    The results of testing of the 30 MJ explosive magnetocumulative generator EMG-720 are reported. This comparatively simple and inexpensive generator is destined for energizing a stationary electro-physical facility placed in a special explosion-protected bunker. The current increase coefficient and the energy increase factor of the generator are as high as 500 and 120, respectively. The generator operating time is 225 s, and its internal operating voltage is higher than 100 kV. (J.U.). 4 figs., 4 refs.

  14. A LabVIEWTM-based detector testing system

    International Nuclear Information System (INIS)

    Yang Haori; Li Yuanjing; Wang Yi; Li Yulan; Li Jin

    2003-01-01

    The construction of a LabVIEW-based detector testing system is described in this paper. In this system, the signal of detector is magnified and digitized, so amplitude or time spectrum can be obtained. The Analog-to-Digital Converter is a peak-sensitive ADC based on VME bus. The virtual instrument constructed by LabVIEW can be used to acquire data, draw spectrum and save testing results

  15. Utility of the k-means clustering algorithm in differentiating apparent diffusion coefficient values of benign and malignant neck pathologies.

    Science.gov (United States)

    Srinivasan, A; Galbán, C J; Johnson, T D; Chenevert, T L; Ross, B D; Mukherji, S K

    2010-04-01

    Does the K-means algorithm do a better job of differentiating benign and malignant neck pathologies compared to only mean ADC? The objective of our study was to analyze the differences between ADC partitions to evaluate whether the K-means technique can be of additional benefit to whole-lesion mean ADC alone in distinguishing benign and malignant neck pathologies. MR imaging studies of 10 benign and 10 malignant proved neck pathologies were postprocessed on a PC by using in-house software developed in Matlab. Two neuroradiologists manually contoured the lesions, with the ADC values within each lesion clustered into 2 (low, ADC-ADC(L); high, ADC-ADC(H)) and 3 partitions (ADC(L); intermediate, ADC-ADC(I); ADC(H)) by using the K-means clustering algorithm. An unpaired 2-tailed Student t test was performed for all metrics to determine statistical differences in the means of the benign and malignant pathologies. A statistically significant difference between the mean ADC(L) clusters in benign and malignant pathologies was seen in the 3-cluster models of both readers (P = .03 and .022, respectively) and the 2-cluster model of reader 2 (P = .04), with the other metrics (ADC(H), ADC(I); whole-lesion mean ADC) not revealing any significant differences. ROC curves demonstrated the quantitative differences in mean ADC(H) and ADC(L) in both the 2- and 3-cluster models to be predictive of malignancy (2 clusters: P = .008, area under curve = 0.850; 3 clusters: P = .01, area under curve = 0.825). The K-means clustering algorithm that generates partitions of large datasets may provide a better characterization of neck pathologies and may be of additional benefit in distinguishing benign and malignant neck pathologies compared with whole-lesion mean ADC alone.

  16. Formal Specification Based Automatic Test Generation for Embedded Network Systems

    Directory of Open Access Journals (Sweden)

    Eun Hye Choi

    2014-01-01

    Full Text Available Embedded systems have become increasingly connected and communicate with each other, forming large-scaled and complicated network systems. To make their design and testing more reliable and robust, this paper proposes a formal specification language called SENS and a SENS-based automatic test generation tool called TGSENS. Our approach is summarized as follows: (1 A user describes requirements of target embedded network systems by logical property-based constraints using SENS. (2 Given SENS specifications, test cases are automatically generated using a SAT-based solver. Filtering mechanisms to select efficient test cases are also available in our tool. (3 In addition, given a testing goal by the user, test sequences are automatically extracted from exhaustive test cases. We’ve implemented our approach and conducted several experiments on practical case studies. Through the experiments, we confirmed the efficiency of our approach in design and test generation of real embedded air-conditioning network systems.

  17. Thermoelectric Generator Emulator for MPPT Testing

    DEFF Research Database (Denmark)

    Man, Elena Anamaria; Sera, Dezso; Máthé, Lászlo

    2015-01-01

    This paper presents a novel approach to use a DC power supply as a thermoelectric generator (TEG) emulator to perform static and dynamic maximum power point tracking (MPPT). First, the electrical characterization of a calcium-manganese-oxide module is performed on a TEG test rig. Afterwards...

  18. A Window Into Clinical Next-Generation Sequencing-Based Oncology Testing Practices.

    Science.gov (United States)

    Nagarajan, Rakesh; Bartley, Angela N; Bridge, Julia A; Jennings, Lawrence J; Kamel-Reid, Suzanne; Kim, Annette; Lazar, Alexander J; Lindeman, Neal I; Moncur, Joel; Rai, Alex J; Routbort, Mark J; Vasalos, Patricia; Merker, Jason D

    2017-12-01

    - Detection of acquired variants in cancer is a paradigm of precision medicine, yet little has been reported about clinical laboratory practices across a broad range of laboratories. - To use College of American Pathologists proficiency testing survey results to report on the results from surveys on next-generation sequencing-based oncology testing practices. - College of American Pathologists proficiency testing survey results from more than 250 laboratories currently performing molecular oncology testing were used to determine laboratory trends in next-generation sequencing-based oncology testing. - These presented data provide key information about the number of laboratories that currently offer or are planning to offer next-generation sequencing-based oncology testing. Furthermore, we present data from 60 laboratories performing next-generation sequencing-based oncology testing regarding specimen requirements and assay characteristics. The findings indicate that most laboratories are performing tumor-only targeted sequencing to detect single-nucleotide variants and small insertions and deletions, using desktop sequencers and predesigned commercial kits. Despite these trends, a diversity of approaches to testing exists. - This information should be useful to further inform a variety of topics, including national discussions involving clinical laboratory quality systems, regulation and oversight of next-generation sequencing-based oncology testing, and precision oncology efforts in a data-driven manner.

  19. A Sigma-Delta ADC with Decimation and Gain Control Function for a Bluetooth Receiver in 130 nm Digital CMOS

    Directory of Open Access Journals (Sweden)

    Koh Jinseok

    2006-01-01

    Full Text Available We present a discrete-time second-order multibit sigma-delta ADC that filters and decimates by two the input data samples. At the same time it provides gain control function in its input sampling stage. A 4-tap FIR switched capacitor (SC architecture was chosen for antialiasing filtering. The decimation-by-two function is realized using divided-by-two clock signals in the antialiasing filter. Antialiasing, gain control, and sampling functions are merged in the sampling network using SC techniques. This compact architecture allows operating the preceding blocks at twice the ADC's clock frequency, thus improving the noise performance of the wireless receiver channel and relaxing settling requirements of the analog building blocks. The presented approach has been validated and incorporated in a commercial single-chip Bluetooth radio realized in a 1.5 V 130 nm digital CMOS process. The measured antialiasing filtering shows better than 75 dB suppression at the folding frequency band edge. A 67 dB dynamic range was measured with a sampling frequency of 37.5MHz.

  20. Pattern Generator for Bench Test of Digital Boards

    Science.gov (United States)

    Berkun, Andrew C.; Chu, Anhua J.

    2012-01-01

    All efforts to develop electronic equipment reach a stage where they need a board test station for each board. The SMAP digital system consists of three board types that interact with each other using interfaces with critical timing. Each board needs to be tested individually before combining into the integrated digital electronics system. Each board needs critical timing signals from the others to be able to operate. A bench test system was developed to support test of each board. The test system produces all the outputs of the control and timing unit, and is delivered much earlier than the timing unit. Timing signals are treated as data. A large file is generated containing the state of every timing signal at any instant. This file is streamed out to an IO card, which is wired directly to the device-under-test (DUT) input pins. This provides a flexible test environment that can be adapted to any of the boards required to test in a standalone configuration. The problem of generating the critical timing signals is then transferred from a hardware problem to a software problem where it is more easily dealt with.

  1. Generating pseudo test collections for learning to rank scientific articles

    NARCIS (Netherlands)

    Berendsen, R.; Tsagkias, M.; de Rijke, M.; Meij, E.

    2012-01-01

    Pseudo test collections are automatically generated to provide training material for learning to rank methods. We propose a method for generating pseudo test collections in the domain of digital libraries, where data is relatively sparse, but comes with rich annotations. Our intuition is that

  2. Path generation algorithm for UML graphic modeling of aerospace test software

    Science.gov (United States)

    Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Chen, Chao

    2018-03-01

    Aerospace traditional software testing engineers are based on their own work experience and communication with software development personnel to complete the description of the test software, manual writing test cases, time-consuming, inefficient, loopholes and more. Using the high reliability MBT tools developed by our company, the one-time modeling can automatically generate test case documents, which is efficient and accurate. UML model to describe the process accurately express the need to rely on the path is reached, the existing path generation algorithm are too simple, cannot be combined into a path and branch path with loop, or too cumbersome, too complicated arrangement generates a path is meaningless, for aerospace software testing is superfluous, I rely on our experience of ten load space, tailor developed a description of aerospace software UML graphics path generation algorithm.

  3. Research on Generating Method of Embedded Software Test Document Based on Dynamic Model

    Science.gov (United States)

    Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Liu, Ying

    2018-03-01

    This paper provides a dynamic model-based test document generation method for embedded software that provides automatic generation of two documents: test requirements specification documentation and configuration item test documentation. This method enables dynamic test requirements to be implemented in dynamic models, enabling dynamic test demand tracking to be easily generated; able to automatically generate standardized, standardized test requirements and test documentation, improved document-related content inconsistency and lack of integrity And other issues, improve the efficiency.

  4. Histogram analysis of ADC in rectal cancer: associations with different histopathological findings including expression of EGFR, Hif1-alpha, VEGF, p53, PD1, and KI 67. A preliminary study.

    Science.gov (United States)

    Meyer, Hans Jonas; Höhn, Annekathrin; Surov, Alexey

    2018-04-06

    Functional imaging modalities like Diffusion-weighted imaging are increasingly used to predict tumor behavior like cellularity and vascularity in different tumors. Histogram analysis is an emergent imaging analysis, in which every voxel is used to obtain a histogram and therefore statistically information about tumors can be provided. The purpose of this study was to elucidate possible associations between ADC histogram parameters and several immunhistochemical features in rectal cancer. Overall, 11 patients with histologically proven rectal cancer were included into the study. There were 2 (18.18%) females and 9 males with a mean age of 67.1 years. KI 67-index, expression of p53, EGFR, VEGF, and Hif1-alpha were semiautomatically estimated. The tumors were divided into PD1-positive and PD1-negative lesions. ADC histogram analysis was performed as a whole lesion measurement using an in-house matlab application. Spearman's correlation analysis revealed a strong correlation between EGFR expression and ADCmax (p=0.72, P=0.02). None of the vascular parameters (VEGF, Hif1-alpha) correlated with ADC parameters. Kurtosis and skewness correlated inversely with p53 expression (p=-0.64, P=0.03 and p=-0.81, P=0.002, respectively). ADCmedian and ADCmode correlated with Ki67 (p=-0.62, P=0.04 and p=-0.65, P=0.03, respectively). PD1-positive tumors showed statistically significant lower ADCmax values in comparison to PD1-negative tumors, 1.93 ± 0.36 vs 2.32 ± 0.47×10 -3 mm 2 /s, p=0.04. Several associations were identified between histogram parameter derived from ADC maps and EGFR, KI 67 and p53 expression in rectal cancer. Furthermore, ADCmax was different between PD1 positive and PD1 negative tumors indicating an important role of ADC parameters for possible future treatment prediction.

  5. A 10-bit 200-kS/s SAR ADC IP core for a touch screen SoC

    International Nuclear Information System (INIS)

    Tong Xingyuan; Yang Yintang; Zhu Zhangming; Sheng Wenfang

    2010-01-01

    Based on a 5 MSBs (most-significant-bits)-plus-5 LSBs (least-significant-bits) C-R hybrid D/A conversion and low-offset pseudo-differential comparison approach, with capacitor array axially symmetric layout topology and resistor string low gradient mismatch placement method, an 8-channel 10-bit 200-kS/s SAR ADC (successive-approximation-register analog-to-digital converter) IP core for a touch screen SoC (system-on-chip) is implemented in a 0.18 μm 1P5M CMOS logic process. Design considerations for the touch screen SAR ADC are included. With a 1.8 V power supply, the DNL (differential non-linearity) and INL (integral non-linearity) of this converter are measured to be about 0.32 LSB and 0.81 LSB respectively. With an input frequency of 91 kHz at 200-kS/s sampling rate, the spurious-free dynamic range and effective-number-of-bits are measured to be 63.2 dB and 9.15 bits respectively, and the power is about 136 μW. This converter occupies an area of about 0.08 mm 2 . The design results show that it is very suitable for touch screen SoC applications. (semiconductor integrated circuits)

  6. Pseudorandom Testing – A Study of the Effect of the Generator Type

    Directory of Open Access Journals (Sweden)

    P. Fišer

    2005-01-01

    Full Text Available The test pattern generator produces test vectors that are applied to the tested circuit during pseudo-random testing of combinational circuits. The nature of the generator thus directly influences the fault coverage achieved. In this paper we discuss the influence of the type of pseudo-random pattern generator on stuck-at fault coverage. Linear feedback shift registers (LFSRs are mostly used as test pattern generators, and the generating polynomial is primitive to ensure the maximum period. We have shown that it is not necessary to use primitive polynomials, and moreover that their using is even undesirable in most cases. This fact is documented by statistical graphs. The necessity of the proper choice of a generating polynomial and an LFSR seed is shown here, by designing a mixed-mode BIST for the ISCAS benchmarks.An alternative to LFSRs are cellular automata (CA. We study the effectiveness of CA when used as pseudo-random pattern generators. The observations are documented by statistical results. 

  7. Testing for cross-subsidisation in the combined heat and power generation sector

    DEFF Research Database (Denmark)

    Amundsen, Eirik S; Andersen, Per; Jensen, Frank

    2011-01-01

    In this paper we examine cross-subsidisation among combined heat and power producers in Denmark.Information on stand-alone costs for heat generation allows us to empirically compare the Faulhaber tests,tests with an upper bound on stand-alone costs (the Palmer tests) and the fully distributed cos...... test (FDC). All tests indicate a substantial amount of cross-subsidisation from heat generation to power generation. It is shown that the FDC test is closer to that of the Faulhaber tests in its results than the Palmer tests. Thus as the Faulhaber tests are considered in the literature...

  8. A measuring generator for testing spectrometric channels

    International Nuclear Information System (INIS)

    Dinh Sy Hien; Kalinkin, A.I.

    1984-01-01

    A measuring generator for testing and tuning an amplitude spectrometric channel is described. The device consists of a pseudo random pulse generator, constructed on shifters, a sawtooth wave generator and a shaper of stable amplitude pulses with exponential decay times. The device is made as CAMAC unit width modules and has the following specifications: average pulse repetition rate of pseudo random pulses is 3.1; 25; 50; 100; 200 kHz; peak amplitude of 2 Hz pulse repetition of saw tooth pulses is 6 V; peak amplitude of exponential shape pulses is 5 V. The block-diagram and basic circuits of the device are given

  9. Radioisotope thermoelectric generator licensed hardware package and certification tests

    International Nuclear Information System (INIS)

    Goldmann, L.H.; Averette, H.S.

    1994-01-01

    This paper presents the Licensed Hardware package and the Certification Test portions of the Radioisotope Thermoelectric Generator Transportation System. This package has been designed to meet those portions of the Code of Federal Regulations (10 CFR 71) relating to ''Type B'' shipments of radioactive materials. The detailed information for the anticipated license is presented in the safety analysis report for packaging, which is now in process and undergoing necessary reviews. As part of the licensing process, a full-size Certification Test Article unit, which has modifications slightly different than the Licensed Hardware or production shipping units, is used for testing. Dimensional checks of the Certification Test Article were made at the manufacturing facility. Leak testing and drop testing were done at the 300 Area of the US Department of Energy's Hanford Site near Richland, Washington. The hardware includes independent double containments to prevent the environmental spread of 238 Pu, impact limiting devices to protect portions of the package from impacts, and thermal insulation to protect the seal areas from excess heat during accident conditions. The package also features electronic feed-throughs to monitor the Radioisotope Thermoelectric Generator's temperature inside the containment during the shipment cycle. This package is designed to safely dissipate the typical 4500 thermal watts produced in the largest Radioisotope Thermoelectric Generators. The package also contains provisions to ensure leak tightness when radioactive materials, such as a Radioisotope Thermoelectric Generator for the Cassini Mission, planned for 1997 by the National Aeronautics and Space Administration, are being prepared for shipment. These provisions include test ports used in conjunction with helium mass spectrometers to determine seal leakage rates of each containment during the assembly process

  10. Test Generators: Teacher's Tool or Teacher's Headache?

    Science.gov (United States)

    Eiser, Leslie

    1988-01-01

    Discusses the advantages and disadvantages of test generation programs. Includes setting up, printing exams and "bells and whistles." Reviews eight computer packages for Apple and IBM personal computers. Compares features, costs, and usage. (CW)

  11. Automatic Model-Based Generation of Parameterized Test Cases Using Data Abstraction

    NARCIS (Netherlands)

    Calamé, Jens R.; Ioustinova, Natalia; Romijn, J.M.T.; Smith, G.; van de Pol, Jan Cornelis

    2007-01-01

    Developing test suites is a costly and error-prone process. Model-based test generation tools facilitate this process by automatically generating test cases from system models. The applicability of these tools, however, depends on the size of the target systems. Here, we propose an approach to

  12. Automatic WSDL-guided Test Case Generation for PropEr Testing of Web Services

    Directory of Open Access Journals (Sweden)

    Konstantinos Sagonas

    2012-10-01

    Full Text Available With web services already being key ingredients of modern web systems, automatic and easy-to-use but at the same time powerful and expressive testing frameworks for web services are increasingly important. Our work aims at fully automatic testing of web services: ideally the user only specifies properties that the web service is expected to satisfy, in the form of input-output relations, and the system handles all the rest. In this paper we present in detail the component which lies at the heart of this system: how the WSDL specification of a web service is used to automatically create test case generators that can be fed to PropEr, a property-based testing tool, to create structurally valid random test cases for its operations and check its responses. Although the process is fully automatic, our tool optionally allows the user to easily modify its output to either add semantic information to the generators or write properties that test for more involved functionality of the web services.

  13. Application of Next Generation Sequencing on Genetic Testing

    DEFF Research Database (Denmark)

    Li, Jian

    The discovery of genetic factors behind increasing number of human diseases and the growth of education of genetic knowledge to the public make demands for genetic testing increase rapidly. However, traditional genetic testing methods cannot meet all kinds of the requirements. Next generation seq...

  14. Testing random number generators for Monte Carlo applications

    International Nuclear Information System (INIS)

    Sim, L.H.

    1992-01-01

    Central to any system for modelling radiation transport phenomena using Monte Carlo techniques is the method by which pseudo random numbers are generated. This method is commonly referred to as the Random Number Generator (RNG). It is usually a computer implemented mathematical algorithm which produces a series of numbers uniformly distributed on the interval [0,1]. If this series satisfies certain statistical tests for randomness, then for practical purposes the pseudo random numbers in the series can be considered to be random. Tests of this nature are important not only for new RNGs but also to test the implementation of known RNG algorithms in different computer environments. Six RNGs have been tested using six statistical tests and one visual test. The statistical tests are the moments, frequency (digit and number), serial, gap, and poker tests. The visual test is a simple two dimensional ordered pair display. In addition the RNGs have been tested in a specific Monte Carlo application. This type of test is often overlooked, however it is important that in addition to satisfactory performance in statistical tests, the RNG be able to perform effectively in the applications of interest. The RNGs tested here are based on a variety of algorithms, including multiplicative and linear congruential, lagged Fibonacci, and combination arithmetic and lagged Fibonacci. The effect of the Bays-Durham shuffling algorithm on the output of a known bad RNG has also been investigated. 18 refs., 11 tabs., 4 figs. of

  15. Secondary coolant circuit operation tests: steam generator feedwater supply

    International Nuclear Information System (INIS)

    Beroux, M.

    1985-01-01

    No one important accident occurred during the start-up tests of the 1300MWe P4 series, concerning the feedwater system of steam generators (SG). This communication comments on some incidents, that the tests allowed to detect very soon and which had no consequences on the operation of units: 1) Water hammer in feedwater tubes, and incidents met in the emergency steam generator water supply circuit. The technological differences between SG 900 and 1300 are pointed out, and the measures taken to prevent this problem are presented. 2) Incidents met on the emergency feedwater supply circuit of steam generators; mechanical or functional modifications involved by these incidents [fr

  16. A Test Generation Framework for Distributed Fault-Tolerant Algorithms

    Science.gov (United States)

    Goodloe, Alwyn; Bushnell, David; Miner, Paul; Pasareanu, Corina S.

    2009-01-01

    Heavyweight formal methods such as theorem proving have been successfully applied to the analysis of safety critical fault-tolerant systems. Typically, the models and proofs performed during such analysis do not inform the testing process of actual implementations. We propose a framework for generating test vectors from specifications written in the Prototype Verification System (PVS). The methodology uses a translator to produce a Java prototype from a PVS specification. Symbolic (Java) PathFinder is then employed to generate a collection of test cases. A small example is employed to illustrate how the framework can be used in practice.

  17. Simultaneous silencing of two arginine decarboxylase genes alters development in Arabidopsis

    Directory of Open Access Journals (Sweden)

    Diana eSánchez-Rangel

    2016-03-01

    Full Text Available Polyamines (PAs are small aliphatic polycations that are found ubiquitously in all organisms. In plants, PAs are involved in diverse biological processes such as growth, development, and stress responses. In Arabidopsis thaliana, the arginine decarboxylase enzymes (ADC1 and 2 catalyze the first step of PA biosynthesis. For a better understanding of PA biological functions, mutants in PA biosynthesis have been generated; however, the double adc1/adc2 mutant is not viable in A. thaliana. In this study, we generated non-lethal A. thaliana lines through an artificial microRNA that simultaneously silenced the two ADC genes (amiR:ADC. The generated transgenic lines (amiR:ADC-L1 and -L2 showed reduced AtADC1 and AtADC2 transcript levels. For further analyses the amiR:ADC-L2 line was selected. We found that the amiR:ADC-L2 line showed a significant decrease of their PA levels. The co-silencing revealed a stunted growth in A. thaliana seedlings, plantlets and delay in its flowering rate; these phenotypes were reverted with PA treatment. In addition, amiR:ADC-L2 plants displayed two seed phenotypes, such as yellow and brownish seeds. The yellow mutant seeds were smaller than adc1, adc2 mutants and wild type seeds; however, the brownish were the smallest seeds with arrested embryos at the torpedo stage. These data reinforce the importance of PA homeostasis in the plant development processes.

  18. Automated Test Case Generation for an Autopilot Requirement Prototype

    Science.gov (United States)

    Giannakopoulou, Dimitra; Rungta, Neha; Feary, Michael

    2011-01-01

    Designing safety-critical automation with robust human interaction is a difficult task that is susceptible to a number of known Human-Automation Interaction (HAI) vulnerabilities. It is therefore essential to develop automated tools that provide support both in the design and rapid evaluation of such automation. The Automation Design and Evaluation Prototyping Toolset (ADEPT) enables the rapid development of an executable specification for automation behavior and user interaction. ADEPT supports a number of analysis capabilities, thus enabling the detection of HAI vulnerabilities early in the design process, when modifications are less costly. In this paper, we advocate the introduction of a new capability to model-based prototyping tools such as ADEPT. The new capability is based on symbolic execution that allows us to automatically generate quality test suites based on the system design. Symbolic execution is used to generate both user input and test oracles user input drives the testing of the system implementation, and test oracles ensure that the system behaves as designed. We present early results in the context of a component in the Autopilot system modeled in ADEPT, and discuss the challenges of test case generation in the HAI domain.

  19. Generic test procedure for the qualification of a nuclear emergency generator

    International Nuclear Information System (INIS)

    Simonis, J.C.; Bowman, S.W.

    1985-01-01

    This paper describes the proposed analytical and experimental procedures for the qualification of the standby generators and exciters used in the Emergency Diesel Generator Systems in a nuclear power plant. The components which require qualification are identified through a failure mode analysis of the systems conducted using engineering drawings updated to include all field changes. The qualification of each component includes the margins given in IEEE Std. 323-1974, ''Qualifying Class 1E Equipment for Nuclear Power Generating Stations.'' These margins are combined with the plant specific data to define an enveloping set of environmental parameters. This set of enveloping parameters, plus margin, form the bases for the analysis or test qualification tasks. Proposed qualification of the composite electrical insulation systems used in the generator and exciter on the form or random wound coils is by traceable testing. However, before testing the thermal and radiation degradation data used in the design of the generator and exciter are evaluated to identify if these data are sufficiently traceable to eliminate the need for additional insulation tests. The required tests are guided by applicable standards

  20. Class hierarchical test case generation algorithm based on expanded EMDPN model

    Institute of Scientific and Technical Information of China (English)

    LI Jun-yi; GONG Hong-fang; HU Ji-ping; ZOU Bei-ji; SUN Jia-guang

    2006-01-01

    A new model of event and message driven Petri network(EMDPN) based on the characteristic of class interaction for messages passing between two objects was extended. Using EMDPN interaction graph, a class hierarchical test-case generation algorithm with cooperated paths (copaths) was proposed, which can be used to solve the problems resulting from the class inheritance mechanism encountered in object-oriented software testing such as oracle, message transfer errors, and unreachable statement. Finally, the testing sufficiency was analyzed with the ordered sequence testing criterion(OSC). The results indicate that the test cases stemmed from newly proposed automatic algorithm of copaths generation satisfies synchronization message sequences testing criteria, therefore the proposed new algorithm of copaths generation has a good coverage rate.

  1. An Adaptive Test Sheet Generation Mechanism Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Huan-Yu Lin

    2012-01-01

    Full Text Available For test-sheet composition systems, it is important to adaptively compose test sheets with diverse conceptual scopes, discrimination and difficulty degrees to meet various assessment requirements during real learning situations. Computation time and item exposure rate also influence performance and item bank security. Therefore, this study proposes an Adaptive Test Sheet Generation (ATSG mechanism, where a Candidate Item Selection Strategy adaptively determines candidate test items and conceptual granularities according to desired conceptual scopes, and an Aggregate Objective Function applies Genetic Algorithm (GA to figure out the approximate solution of mixed integer programming problem for the test-sheet composition. Experimental results show that the ATSG mechanism can efficiently, precisely generate test sheets to meet the various assessment requirements than existing ones. Furthermore, according to experimental finding, Fractal Time Series approach can be applied to analyze the self-similarity characteristics of GA’s fitness scores for improving the quality of the test-sheet composition in the near future.

  2. DESIGN, FABRICATION, AND TESTING OF AN ADVANCED, NON-POLLUTING TURBINE DRIVE GAS GENERATOR

    International Nuclear Information System (INIS)

    Unknown

    2002-01-01

    The objectives of this report period were to complete the development of the Gas Generator design, which was done; fabricate and test of the non-polluting unique power turbine drive gas Gas Generator, which has been postponed. Focus during this report period has been to complete the brazing and bonding necessary to fabricate the Gas Generator hardware, continue making preparations for fabricating and testing the Gas Generator, and continuing the fabrication of the Gas Generator hardware and ancillary hardware in preparation for the test program. Fabrication is more than 95% complete and is expected to conclude in early May 2002. the test schedule was affected by relocation of the testing to another test supplier. The target test date for hot fire testing is now not earlier than June 15, 2002

  3. BIG - a binary generator for testing digital devices

    International Nuclear Information System (INIS)

    Annuziata, M.; Sechi, G.

    1988-01-01

    This paper presents an unusual approach to the testing of digital devices. In order to test real time systems, we have designed, built, and used a digital generator able to send 2047 quadruples of 12-bit words, with a frequency range of up to 0.7 MHz. (orig.)

  4. First Tests of a New Fast Waveform Digitizer for PMT Signal Read-out from Liquid Argon Dark Matter Detectors

    Science.gov (United States)

    Szelc, A. M.; Canci, N.; Cavanna, F.; Cortopassi, A.; D'Incecco, M.; Mini, G.; Pietropaolo, F.; Romboli, A.; Segreto, E.; Acciarri, R.

    A new generation Waveform Digitizer board as been recently made available on the market by CAEN. The new board CAEN V1751 with 8 Channels per board, 10 bit, 1 GS/s Flash ADC Waveform Digitizer (or 4 channel, 10 bit, 2 GS/s Flash ADC Waveform Digitizer -Dual Edge Sampling mode) with threshold and Auto-Trigger capabilities provides an ideal (relatively low-cost) solution for reading signals from liquid Argon detectors for Dark Matter search equipped with an array of PMTs for the detection of scintillation light. The board was extensively used in real experimental conditions to test its usefulness for possible future uses and to compare it with a state of the art digital oscilloscope. As results, PMT Signal sampling at 1 or 2 GS/s is appropriate for the reconstruction of the fast component of the signal scintillation in Argon (characteristic time of about 4 ns) and the extended dynamic range, after a small customization, allows for the detection of signals in the range of energy needed. The bandwidth is found to be adequate and the intrinsic noise is very low.

  5. ADC interface for data server with data preselection for luminosity detector in AIDA-2020 project

    Science.gov (United States)

    Daniluk, W.; Dziedzic, B.; Korcyl, G.; Wojtoń, T.; Zawiejski, L.

    2017-08-01

    Main aim of the AIDA-2020 project is development of detectors for future accelerators. In FCAL Colaboration we are working on forward subdetectors for ILC and CLIC accelerators. My team is developing prototype module which receives data from ADC, provides the data preselection, and transmits them as packages to the data server for further their analysis. Common prototype is based on AC701 evaluation board which contains Artix-7 FPGA and is equipped with SMA connectors for gigabit transceivers and ethernet connector. In my talk I will describe architecture of the device and current state of module development.

  6. Correlation between apparent diffusion coefficient (ADC) and cellularity is different in several tumors: a meta-analysis.

    Science.gov (United States)

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2017-08-29

    The purpose of this meta-analysis was to provide clinical evidence regarding relationship between ADC and cellularity in different tumors based on large patient data. Medline library was screened for associations between ADC and cell count in different tumors up to September 2016. Only publications in English were extracted. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement (PRISMA) was used for the research. Overall, 39 publications with 1530 patients were included into the analysis. The following data were extracted from the literature: authors, year of publication, number of patients, tumor type, and correlation coefficients. The pooled correlation coefficient for all studies was ρ = -0.56 (95 % CI = [-0.62; -0.50]),. Correlation coefficients ranged from ρ =-0.25 (95 % CI = [-0.63; 0.12]) in lymphoma to ρ=-0.66 (95 % CI = [-0.85; -0.47]) in glioma. Other coefficients were as follows: ovarian cancer, ρ = -0.64 (95% CI = [-0.76; -0.52]); lung cancer, ρ = -0.63 (95 % CI = [-0.78; -0.48]); uterine cervical cancer, ρ = -0.57 (95 % CI = [-0.80; -0.34]); prostatic cancer, ρ = -0.56 (95 % CI = [-0.69; -0.42]); renal cell carcinoma, ρ = -0.53 (95 % CI = [-0.93; -0.13]); head and neck squamous cell carcinoma, ρ = -0.53 (95 % CI = [-0.74; -0.32]); breast cancer, ρ = -0.48 (95 % CI = [-0.74; -0.23]); and meningioma, ρ = -0.45 (95 % CI = [-0.73; -0.17]).

  7. Development and Test of a Prototype 100MVA Superconducting Generator

    Energy Technology Data Exchange (ETDEWEB)

    Fogarty, James M.; Bray, James W.

    2007-05-25

    In 2002, General Electric and the US Department of Energy (DOE) entered into a cooperative agreement for the development of a commercialized 100 MVA generator using high temperature superconductors (HTS) in the field winding. The intent of the program was to: • Identify and develop technologies that would be needed for such a generator. • Develop conceptual designs for generators with ratings of 100 MVA and higher using HTS technology. • Perform proof of concept tests at the 1.5 MW level for GE’s proprietary warm iron rotor HTS generator concept. • Design, build, and test a prototype of a commercially viable 100 MVA generator that could be placed on the power grid. This report summarizes work performed during the program and is provided as one of the final program deliverables.

  8. A probabilistic coverage for on-the-fly test generation algorithms

    OpenAIRE

    Goga, N.

    2003-01-01

    This paper describes a way to compute the coverage for an on-the-fly test generation algorithm based on a probabilistic approach. The on-the-fly test generation and execution process and the development process of an implementation from a specification are viewed as a stochastic process. The probabilities of the stochastic processes are integrated in a generalized definition of coverage. The generalized formulas are instantiated for the ioco theory and for the specification of the TorX test g...

  9. Dismantling of the 50 MW steam generator test facility

    International Nuclear Information System (INIS)

    Nakai, S.; Onojima, T.; Yamamoto, S.; Akai, M.; Isozaki, T.; Gunji, M.; Yatabe, T.

    1997-01-01

    We have been dismantling the 50MW Steam Generator Test Facility (50MWSGTF). The objectives of the dismantling are reuse of sodium components to a planned large scale thermal hydraulics sodium test facility and the material examination of component that have been operated for long time in sodium. The facility consisted of primary sodium loop with sodium heater by gas burner as heat source instead of reactor, secondary sodium loop with auxiliary cooling system (ACS) and water/steam system with steam temperature and pressure reducer instead of turbine. It simulated the 1 loop of the Monju cooling system. The rated power of the facility was 50MWt and it was about 1/5 of the Monju power plant. Several sodium removal methods are applied. As for the components to be dismantled such as piping, intermediate heat exchanger (IHX), air cooled heat exchangers (AC), sodium is removed by steam with nitrogen gas in the air or sodium is burned in the air. As for steam generators which material tests are planned, sodium is removed by steam injection with nitrogen gas to the steam generator. The steam generator vessel is filled with nitrogen and no air in the steam generator during sodium removal. As for sodium pumps, pump internal structure is pulled out from the casing and installed into the tank. After the installation, sodium is removed by the same method of steam generator. As for relatively small reuse components such as sodium valves, electromagnet flow meters (EMFs) etc., sodium is removed by alcohol process. (author)

  10. OCL-BASED TEST CASE GENERATION USING CATEGORY PARTITIONING METHOD

    Directory of Open Access Journals (Sweden)

    A. Jalila

    2015-10-01

    Full Text Available The adoption of fault detection techniques during initial stages of software development life cycle urges to improve reliability of a software product. Specification-based testing is one of the major criterions to detect faults in the requirement specification or design of a software system. However, due to the non-availability of implementation details, test case generation from formal specifications become a challenging task. As a novel approach, the proposed work presents a methodology to generate test cases from OCL (Object constraint Language formal specification using Category Partitioning Method (CPM. The experiment results indicate that the proposed methodology is more effective in revealing specification based faults. Furthermore, it has been observed that OCL and CPM form an excellent combination for performing functional testing at the earliest to improve software quality with reduced cost.

  11. Next Generation Drivetrain Development and Test Program

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan; Erdman, Bill; Blodgett, Doug; Halse, Chris; Grider, Dave

    2015-11-03

    This presentation was given at the Wind Energy IQ conference in Bremen, Germany, November 30 through December 2, 2105. It focused on the next-generation drivetrain architecture and drivetrain technology development and testing (including gearbox and inverter software and medium-voltage inverter modules.

  12. Capacitive digital-to-analogue converters with least significant bit down in differential successive approximation register ADCs

    Directory of Open Access Journals (Sweden)

    Lei Sun

    2014-01-01

    Full Text Available This Letter proposes a least significant bit-down switching scheme in the capacitive digital-to-analogue converters (CDACs of successive approximation register analog-to-digital converter (ADC. Under the same unit capacitor, the chip area and the switching energy are halved without increasing the complexity of logic circuits. Compared with conventional CDAC, when it is applied to one of the most efficient switching schemes, V(cm-based structure, it achieves 93% less switching energy and 75% less chip area with the same differential non linearity (DNL/integral non linearity (INL performance.

  13. Overview of the Division 2351 Neutron Generator Test Facility waveform digitizing system. [Explosively activated neutron generators

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, T.C. Jr.

    1978-02-01

    All neutron generator waveforms from units tested at the SLA neutron generator test site are digitized and the digitized data stored in the CDC 6600 tape library for display and analysis using the CDC 6600 computer. The digitizing equipment consists mainly of seven Biomation Model 8100 transient recorders, Digital Equipment Corporation PDP 11/20 computer, RK05 disk, seven-track magnetic tape transport, and appropriate DEC and SLA controllers and interfaces. The PDP 11/20 computer is programmed in BASIC with assembly language drivers. In addition to digitizing waveforms, this equipment is used for other functions such as the automated testing of multiple-operation electronic neutron generators. Although other types of analysis have been done, the largest use of the digitized data has been for various types of graphical displays using the CDC 6600 and either the SD4020 or DX4460 plotters.

  14. A novel low-voltage operational amplifier for low-power pipelined ADCs

    International Nuclear Information System (INIS)

    Fan Mingjun; Ren Junyan; Guo Yao; Li Ning; Ye Fan; Li Lian

    2009-01-01

    A novel low-voltage two-stage operational amplifier employing class-AB architecture is presented. The structure utilizes level-shifters and current mirrors to create the class-AB behavior in the first and second stages. With this structure, the transconductances of the two stages are double compared with the normal configuration without class-AB behaviors with the same current consumption. Thus power can be saved and the operation frequency can be increased. The nested cascode miller compensation and symmetric common-mode feedback circuits are used for large unit-gain bandwidth, good phase margin and stability. Simulation results show that the sample-and-hold of the 12-bit 40-Ms/s pipelined ADC using the proposed amplifier consumes only 5.8 mW from 1.2 V power supply with signal-to-noise-and-distortion ratio 89.5 dB, spurious-free dynamic range 95.7 dB and total harmonic distortion -94.3 dB with Nyquist input signal frequency.

  15. Cryocooled wideband digital channelizing radio-frequency receiver based on low-pass ADC

    International Nuclear Information System (INIS)

    Vernik, Igor V; Kirichenko, Dmitri E; Dotsenko, Vladimir V; Miller, Robert; Webber, Robert J; Shevchenko, Pavel; Talalaevskii, Andrei; Gupta, Deepnarayan; Mukhanov, Oleg A

    2007-01-01

    We have demonstrated a digital receiver performing direct digitization of radio-frequency signals over a wide frequency range from kilohertz to gigahertz. The complete system, consisting of a cryopackaged superconductor all-digital receiver (ADR) chip followed by room-temperature interface electronics and a field programmable gate array (FPGA) based post-processing module, has been developed. The ADR chip comprises a low-pass analog-to-digital converter (ADC) delta modulator with phase modulation-demodulation architecture together with digital in-phase and quadrature mixer and a pair of digital decimation filters. The chip is fabricated using a 4.5 kA cm -2 process and is cryopackaged using a commercial-off-the-shelf cryocooler. Experimental results in HF, VHF, UHF and L bands and their analysis, proving consistent operation of the cryopackaged ADR chip up to 24.32 GHz clock frequency, are presented and discussed

  16. Benchmarking Post-Hartree–Fock Methods To Describe the Nonlinear Optical Properties of Polymethines: An Investigation of the Accuracy of Algebraic Diagrammatic Construction (ADC) Approaches

    KAUST Repository

    Knippenberg, Stefan; Gieseking, Rebecca L.; Rehn, Dirk R.; Mukhopadhyay, Sukrit; Dreuw, Andreas; Bredas, Jean-Luc

    2016-01-01

    -of-merit for all-optical switching. For a series of model polymethines, we compare several algebraic diagrammatic construction (ADC) schemes for the polarization propagator with approximate second-order coupled cluster (CC2) theory, the widely used INDO

  17. Optimization of an FPGA Trigger Based on an Artificial Neural Network for the Detection of Neutrino-Induced Air Showers

    Science.gov (United States)

    Szadkowski, Zbigniew; Głas, Dariusz; Pytel, Krzysztof; Wiedeński, Michał

    2017-06-01

    Neutrinos play a fundamental role in the understanding of the origin of ultrahigh-energy cosmic rays. They interact through charged and neutral currents in the atmosphere generating extensive air showers. However, the very low rate of events potentially generated by neutrinos is a significant challenge for detection techniques and requires both sophisticated algorithms and high-resolution hardware. Air showers initiated by protons and muon neutrinos at various altitudes, angles, and energies were simulated in CORSIKA and the Auger OffLine event reconstruction platforms, giving analog-to-digital convertor (ADC) patterns in Auger water Cherenkov detectors on the ground. The proton interaction cross section is high, so proton “old” showers start their development early in the atmosphere. In contrast to this, neutrinos can generate “young” showers deeply in the atmosphere relatively close to the detectors. Differences between “old” proton and “young” neutrino showers are visible in attenuation factors of ADC waveforms. For the separation of “old” proton and “young” neutrino ADC traces, many three-layer artificial neural networks (ANNs) were tested. They were trained in MATLAB (in a dedicated way -only “old” proton and “young” neutrino showers as patterns) by simulated ADC traces according to the Levenberg-Marquardt algorithm. Unexpectedly, the recognition efficiency is found to be almost independent of the size of the networks. The ANN trigger based on a selected 8-6-1 network was tested in the Cyclone V E FPGA 5CEFA9F31I7, the heart of prototype front-end boards developed for testing new algorithms in the Pierre Auger surface detectors.

  18. Gas Generation Testing of Spherical Resorcinol-Formaldehyde (sRF) Resin

    Energy Technology Data Exchange (ETDEWEB)

    Colburn, Heather A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Camaioni, Donald M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mahoney, Lenna A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Adami, Susan R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2018-01-19

    This report describes gas generation testing of the spherical resorcinol-formaldehyde (sRF) resin that was conducted to support the technology maturation of the LAWPS facility. The current safety basis for the LAWPS facility is based primarily on two studies that had limited or inconclusive data sets. The two studies indicated a 40% increase in hydrogen generation rate of water (as predicted by the Hu model) with sRF resin over water alone. However, the previous studies did not test the range of conditions (process fluids and temperatures) that are expected in the LAWPS facility. Additionally, the previous studies did not obtain replicate test results or comparable liquid-only control samples. All of the testing described in this report, conducted with water, 0.45M nitric acid, and waste simulants with and without sRF resin, returned hydrogen generation rates that are within the current safety basis for the facility of 1.4 times the Hu model output for water.

  19. Preliminary project definition for long duration. Tests of coal fired MHD generators

    International Nuclear Information System (INIS)

    Van der Laken, R.A.

    1992-01-01

    In its final report the Faraday Working Group recommended the CEC amongst others to explore the possibility of a long duration test of a 'state-of-the-art', MHD-generator in order to remove uncertainties concerning the lifetime and availability of such a generator design. The duration of the test should be several thousands of hours, considerably more than the duration tests carried out until now. The scope of the present study is to prepare a project definition document for a long duration test of a coal fired, state-of-the-art MHD-generator

  20. 21 CFR 864.7900 - Thromboplastin generation test.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Thromboplastin generation test. 864.7900 Section 864.7900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7900...

  1. Generating custom test plans for CASE{sup *}Dictionary 5.0

    Energy Technology Data Exchange (ETDEWEB)

    Atkins, K.D. [Boeing Computer Services, Richland, WA (United States)

    1994-04-01

    Most database development organizations use a formal software development methodology that requires a certain amount of formal testing. The amount of formal testing that will be performed will vary from methodology to methodology and from site to site. If a very detailed formal test plan is required for each module in a system, the work involved to produce the test plan can be tedious and costly. After a system has been designed and developed using Oracle*CASE, there is much useful information in the CASE*Dictionary repository. If this information could be tied to specific test requirements, a test plan could be generated automatically, saving much time and resources. This paper shows how CASE*Dictionary can be used to store test plan information that can then be used to generate a specific test plan for each module based on it`s detailed data usage.

  2. Quality Assurance Program Plan for TRUPACT-II Gas Generation Test Program

    International Nuclear Information System (INIS)

    2002-01-01

    The Gas Generation Test Program (GGTP), referred to as the Program, is designed to establish the concentration of flammable gases and/or gas generation rates in a test category waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II). The phrase 'gas generationtesting' shall refer to any activity that establishes the flammable gas concentration or the flammable gas generation rate. This includes, but is not limited to, measurements performed directly on waste containers or during tests performed on waste containers. This Quality Assurance Program Plan (QAPP) documents the quality assurance (QA) and quality control (QC) requirements that apply to the Program. The TRUPACT-II requirements and technical bases for allowable flammable gas concentration and gas generation rates are described in the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC).

  3. Gas Generation from K East Basin Sludges - Series II Testing

    International Nuclear Information System (INIS)

    Bryan, Samuel A.; Delegard, Calvin H.; Schmidt, Andrew J.; Sell, Rachel L.; Silvers, Kurt L.; Gano, Susan R.; Thornton, Brenda M.

    2001-01-01

    This report describes work to examine the gas generation behavior of actual K East (KE) Basin floor, pit and canister sludge. Mixed and unmixed and fractionated KE canister sludge were tested, along with floor and pit sludges from areas in the KE Basin not previously sampled. The first report in this series focused on gas generation from KE floor and canister sludge collected using a consolidated sampling technique. The third report will present results of gas generation testing of irradiated uranium fuel fragments with and without sludge addition. The path forward for management of the K Basin Sludge is to retrieve, ship, and store the sludge at T Plant until final processing at some future date. Gas generation will impact the designs and costs of systems associated with retrieval, transportation and storage of sludge

  4. A test sheet generating algorithm based on intelligent genetic algorithm and hierarchical planning

    Science.gov (United States)

    Gu, Peipei; Niu, Zhendong; Chen, Xuting; Chen, Wei

    2013-03-01

    In recent years, computer-based testing has become an effective method to evaluate students' overall learning progress so that appropriate guiding strategies can be recommended. Research has been done to develop intelligent test assembling systems which can automatically generate test sheets based on given parameters of test items. A good multisubject test sheet depends on not only the quality of the test items but also the construction of the sheet. Effective and efficient construction of test sheets according to multiple subjects and criteria is a challenging problem. In this paper, a multi-subject test sheet generation problem is formulated and a test sheet generating approach based on intelligent genetic algorithm and hierarchical planning (GAHP) is proposed to tackle this problem. The proposed approach utilizes hierarchical planning to simplify the multi-subject testing problem and adopts genetic algorithm to process the layered criteria, enabling the construction of good test sheets according to multiple test item requirements. Experiments are conducted and the results show that the proposed approach is capable of effectively generating multi-subject test sheets that meet specified requirements and achieve good performance.

  5. Testing generative thinking among Swazi children | Mushoriwa ...

    African Journals Online (AJOL)

    The survey research design was used, with interviews employed to collect the data. Crosstabs and a two-sample t-test were used to analyse the data. The study found no significant differences in generative thinking between second and fifth graders in the Swazi sample. In the comparative analyses, while significant ...

  6. Development of a hardware-in-loop attitude control simulator for a CubeSat satellite

    Science.gov (United States)

    Tapsawat, Wittawat; Sangpet, Teerawat; Kuntanapreeda, Suwat

    2018-01-01

    Attitude control is an important part in satellite on-orbit operation. It greatly affects the performance of satellites. Testing of an attitude determination and control subsystem (ADCS) is very challenging since it might require attitude dynamics and space environment in the orbit. This paper develops a low-cost hardware-in-loop (HIL) simulator for testing an ADCS of a CubeSat satellite. The simulator consists of a numerical simulation part, a hardware part, and a HIL interface hardware unit. The numerical simulation part includes orbital dynamics, attitude dynamics and Earth’s magnetic field. The hardware part is the real ADCS board of the satellite. The simulation part outputs satellite’s angular velocity and geomagnetic field information to the HIL interface hardware. Then, based on this information, the HIL interface hardware generates I2C signals mimicking the signals of the on-board rate-gyros and magnetometers and consequently outputs the signals to the ADCS board. The ADCS board reads the rate-gyro and magnetometer signals, calculates control signals, and drives the attitude actuators which are three magnetic torquers (MTQs). The responses of the MTQs sensed by a separated magnetometer are feedback to the numerical simulation part completing the HIL simulation loop. Experimental studies are conducted to demonstrate the feasibility and effectiveness of the simulator.

  7. Automatic Generation of Test Cases from UML Models

    Directory of Open Access Journals (Sweden)

    Constanza Pérez

    2018-04-01

    Full Text Available [Context] The growing demand for high-quality software has caused the industry to incorporate processes to enable them to comply with these standards, but increasing the cost of development. A strategy to reduce this cost is to incorporate quality evaluations from early stages of software development. A technique that facilitates this evaluation is the model-based testing, which allows to generate test cases at early phases using as input the conceptual models of the system. [Objective] In this paper, we introduce TCGen, a tool that enables the automatic generation of abstract test cases starting from UML conceptual models. [Method] The design and implementation of TCGen, a technique that applies different testing criteria to class diagrams and state transition diagrams to generates test cases, is presented as a model-based testing approach. To do that, TCGen uses UML models, which are widely used at industry and a set of algorithms that recognize the concepts in the models in order to generate abstract test cases. [Results] An exploratory experimental evaluation has been performed to compare the TCGen tool with traditional testing. [Conclusions] Even though the exploratory evaluation shows promising results, it is necessary to perform more empirical evaluations in order to generalize the results. Abstract (in Spanish: [Contexto] La creciente demanda de software de alta calidad ha provocado que la industria incorpore procesos para permitirles cumplir con estos estándares, pero aumentando el costo del desarrollo. Una estrategia para reducir este costo es incorporar evaluaciones de calidad desde las primeras etapas del desarrollo del software. Una técnica que facilita esta evaluación es la prueba basada en modelos, que permite generar casos de prueba en fases tempranas utilizando como entrada los modelos conceptuales del sistema. [Objetivo] En este artículo, presentamos TCGen, una herramienta que permite la generación automática de casos de

  8. Development and tests of large nuclear turbo-generator welded rotors

    International Nuclear Information System (INIS)

    Colombie, H.; Thiery, M.; Rotzinger, R.; Pelissou, C.; Tabacco, C.; Fernagut, V.

    2015-01-01

    Turbo-generators require large forgings for the rotor and it is a worldwide practice to manufacture turbo-generator rotor bodies as single piece forgings. Rotors for nuclear applications (4-pole rotors design, 1500/1800 rpm) require forgings of up to 2.0 m diameter and ultra large ingots with weight more than 500 tons. Nowadays only few forge masters can deliver such forgings in the world. Based on the large welding experience Alstom has gained over decades on steam and gas turbines and Alstom's multi piece shrunk turbo-generator rotors, it was suggested to manufacture 4-pole turbo-generator rotors by welding the shaft from aligned cylindrical forgings. Compared to turbine welded rotors, the shaft of a turbo-generator rotor presents differences linked to dimensions/weight, weld depth and electrical application. The manufacture of a 2 disc model allowed to prove through electrical and mechanical analysis the reliability of the concept as well as the reliability of the manufacturing processes through material tests, micro sections, electrical component tests, weld geometry, welding processes (TIG,SAW,...), weld inspection (Ultrasonic testing, radiographic inspection,...) weld heat treatments and machining. Then a full rotor able to replace a single forging rotor was manufactured in order to validate and prove to potential customers the validity of the welded rotor technology. During the first order from EDF of a welded 900 MW spare rotor, the procedure for the Non Destructive Test on a slotted rotor was developed upon EDF request in order to compare future Non Destructive Testing with the finger print of the new rotor. This complete rotor was delivered to EDF in January 2013. This rotor is in operation in a nuclear unit since November 2013. (authors)

  9. Towards a Framework for Generating Tests to Satisfy Complex Code Coverage in Java Pathfinder

    Science.gov (United States)

    Staats, Matt

    2009-01-01

    We present work on a prototype tool based on the JavaPathfinder (JPF) model checker for automatically generating tests satisfying the MC/DC code coverage criterion. Using the Eclipse IDE, developers and testers can quickly instrument Java source code with JPF annotations covering all MC/DC coverage obligations, and JPF can then be used to automatically generate tests that satisfy these obligations. The prototype extension to JPF enables various tasks useful in automatic test generation to be performed, such as test suite reduction and execution of generated tests.

  10. Experiment data report for semiscale Mod-1 test S-28-2 (steam generator tube rupture test)

    International Nuclear Information System (INIS)

    Patton, M.L.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-2 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-2 was conducted from initial conditions of 15 936 kPa and 558 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. For Test S-28-2, accumulator injection into the intact loop hot leg was provided to simulate simulate the rupture of six steam generator tubes

  11. Test and evaluation of Alco/BLH prototype sodium-heated steam generator. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, C.J.; Auge, L.J.; Cho, S.M.; Hanna, R.W.; Prevost, J.R.; Steger, N.A.; Wagner, R.K.

    1971-01-31

    A 30-Mwt prototype sodium-to-sodium intermediate heat exchanger and a 30-Mwt prototype sodium-heated steam generator were tested in combined operation in its Sodium Components Test Installation. This report contains the results of test and evaluation of the steam generator. During plant performance tests, performance degradation was observed, which resulted in the initiation of a diagnostic test series. This test series revealed that under certain operating conditions, the thermohydraulic characteristic of the steam generator changed either suddenly or gradually, resulting in overall performance degradation. A structural failure, requiring retirement of the unit, occurred before the diagnostic test series and analytical support effort were completed. This report describes the thermohydraulic and structural performance, including the structural failures, and related evaluation analyses of the Alco/BLH prototype steam generator performed prior to termination of the test and evaluation program. In addition, the report presents a post-test examination plan to obtain data that could possibly explain the cause of performance anomalies and structural failures experienced during testing.

  12. BEAT: A Web-Based Boolean Expression Fault-Based Test Case Generation Tool

    Science.gov (United States)

    Chen, T. Y.; Grant, D. D.; Lau, M. F.; Ng, S. P.; Vasa, V. R.

    2006-01-01

    BEAT is a Web-based system that generates fault-based test cases from Boolean expressions. It is based on the integration of our several fault-based test case selection strategies. The generated test cases are considered to be fault-based, because they are aiming at the detection of particular faults. For example, when the Boolean expression is in…

  13. Algorithm for evaluation of parameters of ionization chamber signals from the flash-ADC date

    International Nuclear Information System (INIS)

    Baturin, V.N.; Balin, D.V.; Maev, E.M.; Petrov, G.E.; Semenchuk, G.G.

    1991-01-01

    An algorithm for evaluation of parameters of pulses obtained from the ionization chamber (IC) and digitized by Flash-ADC is described. It was designed for determination of the energies and times of arrival of charged particles in DTμ catalyzed fusion that occurs in the IC sensitive volume, in order to measure directly the probability of muon sticking. The algorithm provides the extraction of weak pulses of sloped muon with 50% efficiency, the measurement of fusion energy, especially for long and low amplitude pulses, the recognition of pulse pileups, using special shape analysis procedure. The algorithm was tuned with a special electronic hardware that supplied sequences of pulses with specified amplitudes, durations and shapes and simulation of simulated tritium-noise background. 6 refs.; 7 figs.; 1 tab

  14. Low-intensive proton generators for radiation testing; Nizkointensivnyj protonnyj generator dlya radiatsionnykh ispytanij

    Energy Technology Data Exchange (ETDEWEB)

    Istomin, I V; Gurbich, A F; Semenov, A V

    1994-12-31

    Experiment is conducted and calculations are performed grounding the possibility of creating a low-intensity proton generator based on nuclear reaction. The necessity in such a proton source is defined by the need of conducting long-term testings and by the absence of appropriate equipment.

  15. 50 mm Diameter digital DC/pulse neutron generator for subcritical reactor test

    International Nuclear Information System (INIS)

    Li Gang; Zhang Zhongshuai; Chi Qian; Liu Linmao

    2012-01-01

    A 50 mm diameter digital DC/pulse neutron generator was developed with 25 mm ceramic drive-in target neutron tube. It was applied in the subcritical reactor test of China Institute of Atomic Energy (CIAE). The generator can produce neutron in three modes: DC, pulse and multiple pulse. The maximum neutron yield of the generator is 1 × 10 8 n/s, while the maximum pulse frequency is 10 kHz, and the minimum pulse width is 10 μs. As a remote controlled generator, it is small in volume, easy to be connected and controlled. The tested results indicate that penning ion source has the feature of delay time in glow discharge, and it is easier for glow discharge to happen when switching the DC voltage of penning ion source into pulse. According to these two characteristics, the generator has been modified. This improved generator can be used in many other areas including Prompt Gamma Neutron Activation Analysis (PGNAA), neutron testing and experiment.

  16. 50 mm Diameter digital DC/pulse neutron generator for subcritical reactor test

    Energy Technology Data Exchange (ETDEWEB)

    Li Gang; Zhang Zhongshuai [Northeast Normal University, Changchun 130024 (China); Chi Qian [Guang Hua College of Chang Chun University, Changchun 130117 (China); Liu Linmao, E-mail: ll888@nenu.edu.cn [Northeast Normal University, Changchun 130024 (China)

    2012-11-01

    A 50 mm diameter digital DC/pulse neutron generator was developed with 25 mm ceramic drive-in target neutron tube. It was applied in the subcritical reactor test of China Institute of Atomic Energy (CIAE). The generator can produce neutron in three modes: DC, pulse and multiple pulse. The maximum neutron yield of the generator is 1 Multiplication-Sign 10{sup 8} n/s, while the maximum pulse frequency is 10 kHz, and the minimum pulse width is 10 {mu}s. As a remote controlled generator, it is small in volume, easy to be connected and controlled. The tested results indicate that penning ion source has the feature of delay time in glow discharge, and it is easier for glow discharge to happen when switching the DC voltage of penning ion source into pulse. According to these two characteristics, the generator has been modified. This improved generator can be used in many other areas including Prompt Gamma Neutron Activation Analysis (PGNAA), neutron testing and experiment.

  17. Tubulin Inhibitor-Based Antibody-Drug Conjugates for Cancer Therapy

    Directory of Open Access Journals (Sweden)

    Hao Chen

    2017-08-01

    Full Text Available Antibody-drug conjugates (ADCs are a class of highly potent biopharmaceutical drugs generated by conjugating cytotoxic drugs with specific monoclonal antibodies through appropriate linkers. Specific antibodies used to guide potent warheads to tumor tissues can effectively reduce undesired side effects of the cytotoxic drugs. An in-depth understanding of antibodies, linkers, conjugation strategies, cytotoxic drugs, and their molecular targets has led to the successful development of several approved ADCs. These ADCs are powerful therapeutics for cancer treatment, enabling wider therapeutic windows, improved pharmacokinetic/pharmacodynamic properties, and enhanced efficacy. Since tubulin inhibitors are one of the most successful cytotoxic drugs in the ADC armamentarium, this review focuses on the progress in tubulin inhibitor-based ADCs, as well as lessons learned from the unsuccessful ADCs containing tubulin inhibitors. This review should be helpful to facilitate future development of new generations of tubulin inhibitor-based ADCs for cancer therapy.

  18. Experiment data report for Semiscale Mod-1 test S-28-3 (steam generator tube rupture test)

    International Nuclear Information System (INIS)

    Gillins, R.L.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-3 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-3 was conducted from initial conditions of 15621 kPa and 555 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Twelve steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg

  19. Experiment data report for semiscale Mod-1 test S-28-4 (steam generator tube rupture test)

    International Nuclear Information System (INIS)

    Esparza, V.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-4 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-4 was conducted from initial conditions of 15 646 kPa and 557 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Thirty steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg

  20. Generation of on-line test signals for nuclear instrumentation for PFBR

    International Nuclear Information System (INIS)

    Ram, Rajit; Bhatnagar, P.V.; Rajesh, M.G.; Das, Debashis

    2010-01-01

    Neutron flux monitoring system for PFBR employs pulse signal processing in start up and intermediate power range of reactor operation and Campbell signal processing in intermediate and full power range of reactor operation. Pulse signal processing unit as well as Campbell signal processing unit incorporates FPGA that generates pulse/white noise signal for on-line testing and diagnostic of the channels. In pulse channel fixed/linearly/exponentially varying pulse rate signal is generated over three decades of reactor operation. In the Campbell channel, Poisson distributed noise varying linearly/exponentially is generated over four decades of reactor operation. Multiple numbers of Poisson distributed random pulse trains are summed and amplified to get the white noise signal. Exponentially increasing gain pattern, generated by MATLAB is used to increase the RMS value of the generated noise. The paper discuses the successful testing and validation of pulse and Campbell channel by making use of the generated pulse/white noise signal over wide range of operation for nuclear instrumentation. (author)

  1. The temperature control and water quality regulation for steam generator secondary side hydrostatic test

    International Nuclear Information System (INIS)

    Xiao Bo; Liu Dongyong

    2014-01-01

    The secondary side hydrostatic test for the steam generator of M310 unit is to verify the pressure tightness of steam generator secondary side tube sheet and related systems. As for the importance of the steam generator, the water temperature and water quality of hydrostatic test has strict requirements. The discussion on the water temperature control and water quality regulation for the secondary loop hydrostatic test of Fuqing Unit 1 contribute greatly to the guiding work for the preparation of the steam generator pressure test for M310 unit. (authors)

  2. Efficient Data Generation and Publication as a Test Tool

    Science.gov (United States)

    Einstein, Craig Jakob

    2017-01-01

    A tool to facilitate the generation and publication of test data was created to test the individual components of a command and control system designed to launch spacecraft. Specifically, this tool was built to ensure messages are properly passed between system components. The tool can also be used to test whether the appropriate groups have access (read/write privileges) to the correct messages. The messages passed between system components take the form of unique identifiers with associated values. These identifiers are alphanumeric strings that identify the type of message and the additional parameters that are contained within the message. The values that are passed with the message depend on the identifier. The data generation tool allows for the efficient creation and publication of these messages. A configuration file can be used to set the parameters of the tool and also specify which messages to pass.

  3. SEMICONDUCTOR INTEGRATED CIRCUITS A 10-bit 200-kS/s SAR ADC IP core for a touch screen SoC

    Science.gov (United States)

    Xingyuan, Tong; Yintang, Yang; Zhangming, Zhu; Wenfang, Sheng

    2010-10-01

    Based on a 5 MSBs (most-significant-bits)-plus-5 LSBs (least-significant-bits) C-R hybrid D/A conversion and low-offset pseudo-differential comparison approach, with capacitor array axially symmetric layout topology and resistor string low gradient mismatch placement method, an 8-channel 10-bit 200-kS/s SAR ADC (successive-approximation-register analog-to-digital converter) IP core for a touch screen SoC (system-on-chip) is implemented in a 0.18 μm 1P5M CMOS logic process. Design considerations for the touch screen SAR ADC are included. With a 1.8 V power supply, the DNL (differential non-linearity) and INL (integral non-linearity) of this converter are measured to be about 0.32 LSB and 0.81 LSB respectively. With an input frequency of 91 kHz at 200-kS/s sampling rate, the spurious-free dynamic range and effective-number-of-bits are measured to be 63.2 dB and 9.15 bits respectively, and the power is about 136 μW. This converter occupies an area of about 0.08 mm2. The design results show that it is very suitable for touch screen SoC applications.

  4. Antibody drug conjugates - Trojan horses in the war on cancer.

    Science.gov (United States)

    Iyer, U; Kadambi, V J

    2011-01-01

    Antibody drug conjugates (ADCs) consist of an antibody attached to a cytotoxic drug by means of a linker. ADCs provide a way to couple the specificity of a monoclonal antibody (mAb) to the cytotoxicity of a small-molecule drug and, therefore, are promising new therapies for cancer. ADCs are prodrugs that are inactive in circulation but exert their cytotoxicity upon binding to the target cancer cell. Earlier unsuccessful attempts to generate ADCs with therapeutic value have emphasized the important role each component plays in determining the efficacy and safety of the final ADC. Scientific advances in engineering antibodies for maximum efficacy as anticancer agents, identification of highly cytotoxic molecules, and generation of linkers with increased stability in circulation have all contributed to the development of the many ADCs that are currently in clinical trials. This review discusses parameters that guide the selection of the components of an ADC to increase its therapeutic window, provides a brief look at ADCs currently in clinical trials, and discusses future challenges in this field. Copyright © 2011. Published by Elsevier Inc.

  5. Gas Generation from K East Basin Sludges - Series I Testing

    International Nuclear Information System (INIS)

    Delegard, Calvin H.; Bryan, Samuel A.; Schmidt, Andrew J.; Bredt, Paul R.; King, Christopher M.; Sell, Rachel L.; Burger, Leland L.; Silvers, Kurt L.

    2000-01-01

    This report describes work to examine the gas generation behavior of actual K East (KE) Basin floor and canister sludge. The path forward for management of the K Basin Sludge is to retrieve, ship, and store the sludge at T Plant until final processing at some future date. Gas generation will impact the designs and costs of systems associated with retrieval, transportation and storage of sludge. The overall goals for this testing were to collect detailed gas generation rate and composition data to ascertain the quantity and reactivity of the metallic uranium (and other reactive species) present in the K Basin sludge. The gas generation evaluation included four large-scale vessels (850 ml) and eight small-scale vessels (30 ml) in an all-metal, leak tight system. The tests were conducted for several thousand hours at ambient and elevated temperatures (32 C, 40 C, 60 C, 80 C, and 95 C) to accelerated the reactions and provide conclusive gas generation data within a reasonable testing period. The sludge used for these tests was collected from the KE Basin floor and canister barrels (containing damaged spent fuel elements) using a consolidated sampling technique (i.e., material from several locations was combined to form ''consolidated samples''). Portions of these samples were sieved to separate particles greater than 250 m (P250) from particle less than 250 m (M250). This separation was performed to mimic the separation operations that are planned during the retrieval of certain K Basin sludge types and to gain a better understanding of how uranium metal is distributed in the sludge. The corrosion rate of the uranium metal particles in the sludge was found to agree reasonably well with corrosion rates reported in the literature

  6. An FPGA-based slowcontrol module and a baseline shifting extension card for the sampling-ADC readout of the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Urff, Georg; Poller, Timo [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    At the electron accelerator ELSA (Bonn) the CBELSA/TAPS experiment investigates the photoproduction of mesons off protons and neutrons. The CsI(Tl)-crystals of the Crystal Barrel calorimeter are being upgraded from a PIN-diode readout to an APD readout. In the context of this upgrade, an FPGA-based Sampling-ADC (SADC) is presently being developed (HK 304). A Slow-control Module for the SADC with TCP/Telnet access has been developed on the basis of a Spartan6 FPGA. Control and monitoring of the SADC's power supply as well as control of parameters of the analog and digital data processing in the SADC is realized via PMBus/I{sup 2}C. The prototype as well as an overview of its functionality will be presented. In order to fully utilize the dynamic input range of the SADCs, an interfacing extension board was designed. It receives the differential signal generated by previous amplification stages and adds an individual DC offset voltage to each channel supplied by a digital-to-analog converter. The circuit and the used techniques as well as simulations and measurements are presented.

  7. A 0.7V 7-to-10bit 0-to-2MS/s Flexible SAR ADC for Ultra Low-Power Wireless Sensor Nodes

    NARCIS (Netherlands)

    Harpe, P.J.A.; Dolmans, G.; Philips, K.J.P.; Groot, de H.W.H.

    2012-01-01

    This paper presents a flexible SAR ADC in 90nm CMOS for wireless sensor nodes. By supporting resolutions from 7 to 10bit and sample rates from DC to 2MS/s, this design can be used for a variety of applications such as sensor interfacing and receiver frontends. Flexibility is achieved by a

  8. Investigational Antibody-Drug Conjugates for Treatment of B-lineage Malignancies.

    Science.gov (United States)

    Herrera, Alex F; Molina, Arturo

    2018-05-10

    Antibody-drug conjugates (ADCs) are tripartite molecules consisting of a monoclonal antibody, a covalent linker, and a cytotoxic payload. ADC development has aimed to target the specificity inherent in antigen-antibody interactions to deliver potent cytotoxins preferentially to tumor cells and maximize antitumor activity and simultaneously minimize off-target toxicity. The earliest ADCs provided disappointing results in the clinic; however, the lessons learned regarding the need for human or humanized antibodies, more stable linkers, and greater potency payloads led to improved ADCs. Three ADCs, gemtuzumab ozogamicin, brentuximab vedotin (BV), and inotuzumab ozogamicin, have been approved for hematologic malignancies. Site-specific conjugation methods have now resulted in a new generation of more uniform, molecularly defined ADCs. These are expected to display improved in vivo properties and have recently entered the clinic. We reviewed investigational ADCs currently in clinical testing for the treatment of B-cell lineage malignancies, including leukemias, lymphomas, and multiple myeloma. The rationales for antigen targeting, data reported to date, current trial status, and preclinical results for several newer ADCs expected to enter first-in-human studies are presented. Owing to the large number of ongoing and reported BV clinical studies, only the studies of BV for diffuse large B-cell lymphoma and those combining BV with checkpoint inhibitors in B-lineage malignancies have been reviewed. With > 40 ongoing clinical trials and 7 investigational ADCs already having advanced to phase II studies, the role of ADCs in the armamentarium for the treatment of B-lineage malignancies continues to be elucidated. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  9. A capacitive DAC with custom 3-D 1-fF MOM unit capacitors optimized for fast-settling routing in high speed SAR ADCs

    International Nuclear Information System (INIS)

    Chen Chixiao; Xiang Jixuan; Chen Huabin; Xu Jun; Ye Fan; Li Ning; Ren Junyan

    2015-01-01

    Asynchronous successive approximation register (SAR) analog-to-digital converters (ADC) feature high energy efficiency but medium performance. From the point of view of speed, the key bottleneck is the unit capacitor size. In this paper, a small size three-dimensional (3-D) metal—oxide—metal (MOM) capacitor is proposed. The unit capacitor has a capacitance of 1-fF. It shapes as an umbrella, which is designed for fast settling consideration. A comparison among the proposed capacitor with other 3-D MOM capacitors is also given in the paper. To demonstrate the effectiveness of the MOM capacitor, a 6-b capacitive DAC is implemented in TSMC 1P9M 65 nm LP CMOS technology. The DAC consumes a power dissipation of 0.16 mW at the rate of 100 MS/s, excluding a source-follower based output buffer. Static measurement result shows that INL is less than ±1 LSB and DNL is less than ±0.5 LSB. In addition, a 100 MS/s 9-bit SAR ADC with the proposed 3-D capacitor is simulated. (paper)

  10. WTP Waste Feed Qualification: Hydrogen Generation Rate Measurement Apparatus Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Stone, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Smith, T. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Pareizs, J. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-06-01

    The generation rate of hydrogen gas in the Hanford tank waste will be measured during the qualification of the staged tank waste for processing in the Hanford Tank Waste Treatment and Immobilization Plant. Based on a review of past practices in measurement of the hydrogen generation, an apparatus to perform this measurement has been designed and tested for use during waste feed qualification. The hydrogen generation rate measurement apparatus (HGRMA) described in this document utilized a 100 milliliter sample in a continuously-purged, continuously-stirred vessel, with measurement of hydrogen concentration in the vent gas. The vessel and lid had a combined 220 milliliters of headspace. The vent gas system included a small condenser to prevent excessive evaporative losses from the sample during the test, as well as a demister and filter to prevent particle migration from the sample to the gas chromatography system. The gas chromatograph was an on line automated instrument with a large-volume sample-injection system to allow measurement of very low hydrogen concentrations. This instrument automatically sampled the vent gas from the hydrogen generation rate measurement apparatus every five minutes and performed data regression in real time. The fabrication of the hydrogen generation rate measurement apparatus was in accordance with twenty three (23) design requirements documented in the conceptual design package, as well as seven (7) required developmental activities documented in the task plan associated with this work scope. The HGRMA was initially tested for proof of concept with physical simulants, and a remote demonstration of the system was performed in the Savannah River National Laboratory Shielded Cells Mockup Facility. Final verification testing was performed using non-radioactive simulants of the Hanford tank waste. Three different simulants were tested to bound the expected rheological properties expected during waste feed qualification testing. These

  11. Generating and testing methods for consumer-oriented product development

    International Nuclear Information System (INIS)

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process [nl

  12. Automatic Test Pattern Generator for Fuzzing Based on Finite State Machine

    Directory of Open Access Journals (Sweden)

    Ming-Hung Wang

    2017-01-01

    Full Text Available With the rapid development of the Internet, several emerging technologies are adopted to construct fancy, interactive, and user-friendly websites. Among these technologies, HTML5 is a popular one and is widely used in establishing modern sites. However, the security issues in the new web technologies are also raised and are worthy of investigation. For vulnerability investigation, many previous studies used fuzzing and focused on generation-based approaches to produce test cases for fuzzing; however, these methods require a significant amount of knowledge and mental efforts to develop test patterns for generating test cases. To decrease the entry barrier of conducting fuzzing, in this study, we propose a test pattern generation algorithm based on the concept of finite state machines. We apply graph analysis techniques to extract paths from finite state machines and use these paths to construct test patterns automatically. According to the proposal, fuzzing can be completed through inputting a regular expression corresponding to the test target. To evaluate the performance of our proposal, we conduct an experiment in identifying vulnerabilities of the input attributes in HTML5. According to the results, our approach is not only efficient but also effective for identifying weak validators in HTML5.

  13. Tests and analysis on steam generator tube failure propagation

    International Nuclear Information System (INIS)

    Tanabe, Hiromi

    1990-01-01

    The understanding of leak enlargement and failure propagation behavior is essential to select a design basis leak (DBL) of LMFBR steam generators. Therefore, various series of experiments, such as self-enlargement tests, target wastage tests, failure propagation tests were conducted in a wide range of leak using test facilities of SWAT at PNC/OEC. Especially, in the large leak tests, potential of overheating failure was investigated under a prototypical steam cooling condition inside target tubes. In the small leak, the difference of wastage resistivity was clarified among several tube materials such as 9-chrome steels. In regard to an analytical approach, a computer code LEAP (Leak Enlargement and Propagation) was developed on the basis of all of these experimental results. The code was used to validate the previously selected DBL of the prototype reactor, Monju, steam generator. This approach proved to be successful in spite of somewhat over-conservatism in the analysis. Moreover, LEAP clarified the effectiveness of a rapid steam dump and an enhanced leak detection system. The code improvement toward a realistic analysis is desired, however, to lessen the DBL for a future large plant and then the re-evaluation of the experimental data such as the size of secondary failure is under way. (author). 4 refs, 8 figs, 1 tab

  14. Performance tests of developed silicon strip detector by using a 150 GeV electron beam

    International Nuclear Information System (INIS)

    Hyun, Hyojung; Jung, Sunwoo; Kah, Dongha; Kang, Heedong; Kim, Hongjoo; Park, Hwanbae

    2008-01-01

    We manufactured and characterized a silicon micro-strip detector to be used in a beam tracker. A silicon detector features a DC-coupled silicon strip sensor with VA1 Prime2 analog readout chips. The silicon strip sensors have been fabricated on 5-in. wafers at Electronics and Telecommunications Research Institute (Daejeon, Korea). The silicon strip sensor is single-sided and has 32 channels with a 1 mm pitch, and its active area is 3.2 by 3.2 cm 2 with 380 μm thickness. The readout electronics consists of VA hybrid, VA Interface, and FlashADC and Control boards. Analog signals from the silicon strip sensor were being processed by the analog readout chips on the VA hybrid board. Analog signals were then changed into digital signals by a 12 bit 25 MHz FlashADC. The digital signals were read out by the Linux-operating PC through the FlashADC-USB2 interface. The DAQ system and analysis programs were written in the framework of ROOT package. The beam test with the silicon detector had been performed at CERN beam facility. We used a 150 GeV electron beam out of the SPS(Super Proton Synchrotron) H2 beam line. We present beam test setup and measurement result of signal-to-noise ratio of each strip channel. (author)

  15. A radiation-hard dual-channel 12-bit 40 MS/s ADC prototype for the ATLAS liquid argon calorimeter readout electronics upgrade at the CERN LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kuppambatti, J. [Columbia University, Dept. of Electrical Engineering, New York, NY (United States); Ban, J. [Columbia University, Nevis Laboratories, Irvington, NY (United States); Andeen, T., E-mail: tandeen@utexas.edu [Columbia University, Nevis Laboratories, Irvington, NY (United States); Brown, R.; Carbone, R. [Columbia University, Nevis Laboratories, Irvington, NY (United States); Kinget, P. [Columbia University, Dept. of Electrical Engineering, New York, NY (United States); Brooijmans, G.; Sippach, W. [Columbia University, Nevis Laboratories, Irvington, NY (United States)

    2017-05-21

    The readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider requires a radiation-hard ADC. The design of a radiation-hard dual-channel 12-bit 40 MS/s pipeline ADC for this use is presented. The design consists of two pipeline A/D channels each with four Multiplying Digital-to-Analog Converters followed by 8-bit Successive-Approximation-Register analog-to-digital converters. The custom design, fabricated in a commercial 130 nm CMOS process, shows a performance of 67.9 dB SNDR at 10 MHz for a single channel at 40 MS/s, with a latency of 87.5 ns (to first bit read out), while its total power consumption is 50 mW/channel. The chip uses two power supply voltages: 1.2 and 2.5 V. The sensitivity to single event effects during irradiation is measured and determined to meet the system requirements.

  16. PC-based analog signal generator for simulated detector signals and arbitrary test waveforms for testing the nuclear instruments

    International Nuclear Information System (INIS)

    Catanescu, V.

    1999-01-01

    This work is performed in cooperation with IAEA-Vienna as a project, proposed as part of Agency's C o-ordinated Research Programme of Development of Computer-based Troubleshooting Tools and Instruments. A convenient way for testing and calibrating modern scientific equipment is to connect the test instruments to a personal computer to get additional feasibilities. This way, all settings for test, measurement and data acquisition functions are done by means of PC and are controlled by software drivers. This multifunctional spectrometric pulse generator is able to characterize different parts of high-resolution nuclear spectroscopy chain (preamplifier, amplifier, analog to digital converter, multichannel analyzer) as well as the whole chain. For this it generates periodic or random pulses with shape, time and amplitude specifications controlled by PC. Characteristics such as integral linearity, differential linearity, dead time, rate channel shifting and others will be easily determined. The block diagram of the multifunctional spectrometric generator is shown. The main sections are: PC-interface, control registers and command generation; PC-controlled periodic and random logic pulse oscillators; PC-controlled delay and width of periodic or random logic pulses; constant and ultra-linear ramp references for spectrometric pulse generation; generation of the tail and flat top pulses with PC-controlled amplitude and decay time; semi-gaussian pulse generation, polarity inverter and output amplifier. The specifications for generated signal correspond to: shape, time specifications and amplitude size. (author)

  17. Developing the Persian version of the homophone meaning generation test.

    Science.gov (United States)

    Ebrahimipour, Mona; Motamed, Mohammad Reza; Ashayeri, Hassan; Modarresi, Yahya; Kamali, Mohammad

    2016-01-01

    Finding the right word is a necessity in communication, and its evaluation has always been a challenging clinical issue, suggesting the need for valid and reliable measurements. The Homophone Meaning Generation Test (HMGT) can measure the ability to switch between verbal concepts, which is required in word retrieval. The purpose of this study was to adapt and validate the Persian version of the HMGT. The first phase involved the adaptation of the HMGT to the Persian language. The second phase concerned the psychometric testing. The word-finding performance was assessed in 90 Persian-speaking healthy individuals (20-50 year old; 45 males and 45 females) through three naming tasks: Semantic Fluency, Phonemic Fluency, and Homophone Meaning Generation Test. The participants had no history of neurological or psychiatric diseases, alcohol abuse, severe depression, or history of speech, language, or learning problems. The internal consistency coefficient was larger than 0.8 for all the items with a total Cronbach's alpha of 0.80. Interrater and intrarater reliability were also excellent. The validity of all items was above 0.77, and the content validity index (0.99) was appropriate. The Persian HMGT had strong convergent validity with semantic and phonemic switching and adequate divergent validity with semantic and phonemic clustering. The Persian version of the Homophone Meaning Generation Test is an appropriate, valid, and reliable test to evaluate the ability to switch between verbal concepts in the assessment of word-finding performance.

  18. Generation of Long-time Complex Signals for Testing the Instruments for Detection of Voltage Quality Disturbances

    Science.gov (United States)

    Živanović, Dragan; Simić, Milan; Kokolanski, Zivko; Denić, Dragan; Dimcev, Vladimir

    2018-04-01

    Software supported procedure for generation of long-time complex test sentences, suitable for testing the instruments for detection of standard voltage quality (VQ) disturbances is presented in this paper. This solution for test signal generation includes significant improvements of computer-based signal generator presented and described in the previously published paper [1]. The generator is based on virtual instrumentation software for defining the basic signal parameters, data acquisition card NI 6343, and power amplifier for amplification of output voltage level to the nominal RMS voltage value of 230 V. Definition of basic signal parameters in LabVIEW application software is supported using Script files, which allows simple repetition of specific test signals and combination of more different test sequences in the complex composite test waveform. The basic advantage of this generator compared to the similar solutions for signal generation is the possibility for long-time test sequence generation according to predefined complex test scenarios, including various combinations of VQ disturbances defined in accordance with the European standard EN50160. Experimental verification of the presented signal generator capability is performed by testing the commercial power quality analyzer Fluke 435 Series II. In this paper are shown some characteristic complex test signals with various disturbances and logged data obtained from the tested power quality analyzer.

  19. Quantum random number generation for loophole-free Bell tests

    Science.gov (United States)

    Mitchell, Morgan; Abellan, Carlos; Amaya, Waldimar

    2015-05-01

    We describe the generation of quantum random numbers at multi-Gbps rates, combined with real-time randomness extraction, to give very high purity random numbers based on quantum events at most tens of ns in the past. The system satisfies the stringent requirements of quantum non-locality tests that aim to close the timing loophole. We describe the generation mechanism using spontaneous-emission-driven phase diffusion in a semiconductor laser, digitization, and extraction by parity calculation using multi-GHz logic chips. We pay special attention to experimental proof of the quality of the random numbers and analysis of the randomness extraction. In contrast to widely-used models of randomness generators in the computer science literature, we argue that randomness generation by spontaneous emission can be extracted from a single source.

  20. Histogram analysis of apparent diffusion coefficient maps for the differentiation between lymphoma and metastatic lymph nodes of squamous cell carcinoma in head and neck region.

    Science.gov (United States)

    Wang, Yan-Jun; Xu, Xiao-Quan; Hu, Hao; Su, Guo-Yi; Shen, Jie; Shi, Hai-Bin; Wu, Fei-Yun

    2018-06-01

    Background To clarify the nature of cervical malignant lymphadenopathy is highly important for the diagnosis and differential diagnosis of head and neck tumors. Purpose To investigate the role of first-order apparent diffusion coefficient (ADC) histogram analysis for differentiating lymphoma from metastatic lymph nodes of squamous cell carcinoma (SCC) in the head and neck region. Material and Methods Diffusion-weighted imaging (DWI) data of 67 patients (lymphoma, n = 20; SCC, n = 47) with malignant lymphadenopathy were retrospectively analyzed. The SCC group was divided into nasopharyngeal SCC and non-nasopharyngeal SCC groups. The ADC histogram features (ADC 10 , ADC 25 , ADC mean , ADC median , ADC 75 , ADC 90 , skewness, and kurtosis) were derived and then compared by independent-samples t-test and one-way analysis of variance test, respectively. Receiver operating characteristic curve analyses were employed to investigate diagnostic performance of the significant parameters. Results Lymphoma showed significantly lower ADC mean , ADC median , ADC 75 , and ADC 90 than SCC (all P  0.05). Lymphoma showed significantly lower ADC 25 , ADC mean , ADC median , ADC 75 , and ADC 90 than non-nasopharyngeal SCC (all P histogram analysis is capable of differentiating lymphoma from metastatic lymph nodes of SCC, especially those of non-nasopharyngeal SCC.

  1. Kolmogorov complexity, pseudorandom generators and statistical models testing

    Czech Academy of Sciences Publication Activity Database

    Šindelář, Jan; Boček, Pavel

    2002-01-01

    Roč. 38, č. 6 (2002), s. 747-759 ISSN 0023-5954 R&D Projects: GA ČR GA102/99/1564 Institutional research plan: CEZ:AV0Z1075907 Keywords : Kolmogorov complexity * pseudorandom generators * statistical models testing Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.341, year: 2002

  2. 40 CFR 53.22 - Generation of test atmospheres.

    Science.gov (United States)

    2010-07-01

    ... specifies preferred methods for generating test atmospheres and suggested methods of verifying the... Tentative method of analysis for H2 S content of the atmosphere, p. 426, reference 5. Methane Cylinder of... by revising Table B-2 in paragraph (d), effective Aug. 23, 2010. For the convenience of the user, the...

  3. Experiment data report for Semiscale Mod-1 Test S-28-1 (steam generator tube rupture test series)

    International Nuclear Information System (INIS)

    Collins, B.L.; Coppin, C.E.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-1 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-1 was conducted from initial conditions of 15 767 kPa and 557 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Sixty steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg

  4. An FPGA-based sampling-ADC readout for the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Muellers, Johannes [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Marciniewski, Pawel [Angstroemlaboratoriet, Uppsala (Sweden); Collaboration: CBELSA/TAPS-Collaboration

    2015-07-01

    The CBELSA/TAPS experiment at the electron accelerator ELSA (Bonn) investigates the photoproduction of mesons off protons and neutrons. Presently the readout of the CsI(Tl)-crystals of the Crystal Barrel calorimeter is being upgraded from a PIN-diode readout to an APD readout to create a fast signal for first-level-triggering. This will increase the trigger efficiency especially for final states with only neutral particles substantially. To increase the possible data readout rate, which is currently limited by the digitization stage (LeCroy QDC 1885F) to ∼ 2 kHz, the implementation of a new Sampling-ADC (SADC) readout is being prepared. Based on the 64-channel PANDA-SADC, the CB-SADC design was modified and adapted to the needs of the CBELSA/TAPS experiment. It offers 64 channels in one NIM module, together with modular analog or FPGA-based digital shaping. The data transfer will be realized by two standard gigabit links. Using an FPGA together with SADCs provides a multitude of possibilities for online feature extraction, such as the determination of the energy deposited in the crystal, TDC capabilities and pile-up detection and recovery.

  5. Transcriptome profiling of the Australian arid-land plant Eremophila serrulata (A.DC.) Druce (Scrophulariaceae) for the identification of monoterpene synthases.

    Science.gov (United States)

    Kracht, Octavia Natascha; Ammann, Ann-Christin; Stockmann, Julia; Wibberg, Daniel; Kalinowski, Jörn; Piotrowski, Markus; Kerr, Russell; Brück, Thomas; Kourist, Robert

    2017-04-01

    Plant terpenoids are a large and highly diverse class of metabolites with an important role in the immune defense. They find wide industrial application as active pharmaceutical ingredients, aroma and fragrance compounds. Several Eremophila sp. derived terpenoids have been documented. To elucidate the terpenoid metabolism, the transcriptome of juvenile and mature Eremophila serrulata (A.DC.) Druce (Scrophulariaceae) leaves was sequenced and a transcript library was generated. We report on the first transcriptomic dataset of an Eremophila plant. IlluminaMiSeq sequencing (2 × 300 bp) revealed 7,093,266 paired reads, which could be assembled to 34,505 isogroups. To enable detection of terpene biosynthetic genes, leaves were separately treated with methyl jasmonate, a well-documented inducer of plant secondary metabolites. In total, 21 putative terpene synthase genes were detected in the transcriptome data. Two terpene synthase isoenzymatic genes, termed ES01 and ES02, were successfully expressed in E. coli. The resulting proteins catalyzed the conversion of geranyl pyrophosphate, the universal substrate of monoterpene synthases to myrcene and Z-(b)-ocimene, respectively. The transcriptomic data and the discovery of the first terpene synthases from Eremophila serrulata are the initial step for the understanding of the terpene metabolism in this medicinally important plant genus. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. QIN DAWG Validation of Gradient Nonlinearity Bias Correction Workflow for Quantitative Diffusion-Weighted Imaging in Multicenter Trials.

    Science.gov (United States)

    Malyarenko, Dariya I; Wilmes, Lisa J; Arlinghaus, Lori R; Jacobs, Michael A; Huang, Wei; Helmer, Karl G; Taouli, Bachir; Yankeelov, Thomas E; Newitt, David; Chenevert, Thomas L

    2016-12-01

    Previous research has shown that system-dependent gradient nonlinearity (GNL) introduces a significant spatial bias (nonuniformity) in apparent diffusion coefficient (ADC) maps. Here, the feasibility of centralized retrospective system-specific correction of GNL bias for quantitative diffusion-weighted imaging (DWI) in multisite clinical trials is demonstrated across diverse scanners independent of the scanned object. Using corrector maps generated from system characterization by ice-water phantom measurement completed in the previous project phase, GNL bias correction was performed for test ADC measurements from an independent DWI phantom (room temperature agar) at two offset locations in the bore. The precomputed three-dimensional GNL correctors were retrospectively applied to test DWI scans by the central analysis site. The correction was blinded to reference DWI of the agar phantom at magnet isocenter where the GNL bias is negligible. The performance was evaluated from changes in ADC region of interest histogram statistics before and after correction with respect to the unbiased reference ADC values provided by sites. Both absolute error and nonuniformity of the ADC map induced by GNL (median, 12%; range, -35% to +10%) were substantially reduced by correction (7-fold in median and 3-fold in range). The residual ADC nonuniformity errors were attributed to measurement noise and other non-GNL sources. Correction of systematic GNL bias resulted in a 2-fold decrease in technical variability across scanners (down to site temperature range). The described validation of GNL bias correction marks progress toward implementation of this technology in multicenter trials that utilize quantitative DWI.

  7. Generating realistic environments for cyber operations development, testing, and training

    Science.gov (United States)

    Berk, Vincent H.; Gregorio-de Souza, Ian; Murphy, John P.

    2012-06-01

    Training eective cyber operatives requires realistic network environments that incorporate the structural and social complexities representative of the real world. Network trac generators facilitate repeatable experiments for the development, training and testing of cyber operations. However, current network trac generators, ranging from simple load testers to complex frameworks, fail to capture the realism inherent in actual environments. In order to improve the realism of network trac generated by these systems, it is necessary to quantitatively measure the level of realism in generated trac with respect to the environment being mimicked. We categorize realism measures into statistical, content, and behavioral measurements, and propose various metrics that can be applied at each level to indicate how eectively the generated trac mimics the real world.

  8. Diffusion-weighted MRI of the prostate at 3.0 T: Comparison of endorectal coil (ERC) MRI and phased-array coil (PAC) MRI—The impact of SNR on ADC measurement

    International Nuclear Information System (INIS)

    Mazaheri, Yousef; Vargas, H. Alberto; Nyman, Gregory; Shukla-Dave, Amita; Akin, Oguz; Hricak, Hedvig

    2013-01-01

    Purpose: To compare ADC values measured from diffusion-weighted MR (DW-MR) images of the prostate obtained with both endorectal and phased-array coils (ERC + PAC) to those from DW-MRI images obtained with an eight-channel torso phased-array coil (PAC) at 3.0 T. Methods: The institutional review board issued a waiver of informed consent for this HIPAA-compliant study. Twenty-five patients with biopsy-proven prostate cancer underwent standard 3-T MRI using 2 different coil arrangements (ERC + PAC and PAC only) in the same session. DW-MRI at five b-values (0, 600, 1000, 1200, and 1500 s/mm 2 ) were acquired using both coil arrangements. On b = 0 images, signal-to-noise ratios (SNRs) were measured as the ratio of the mean signal from PZ and TZ ROIs to the standard deviation from the mean signal in an artifact-free ROI in the rectum. Matching regions-of-interest (ROIs) were identified in the peripheral zone and transition zone on ERC-MRI and PAC-MRI. For each ROI, mean ADC values for all zero and non-zero b-value combinations were computed. Results: Mean SNR with ERC-MRI at PZ (66.33 ± 27.07) and TZ (32.69 ± 12.52) was 9.27 and 5.52 times higher than with PAC-MRI ((7.32 ± 2.30) and (6.13 ± 1.56), respectively) (P < 0.0001 for both). ADCs from DW-MR images obtained with all b-values in the PZ and TZ were significantly lower with PAC-MRI than with ERC-MRI (P < 0.001 for all). Conclusion: Lower SNR of DW-MR images of the prostate obtained with a PAC can significantly decrease ADC values at higher b-values compared to similar measurements obtained using the ERC. To address these requirements, clinical MR systems should have image processing capabilities which incorporate the noise distribution

  9. LYSO crystal testing for an EDM polarimeter

    Science.gov (United States)

    Müller, F.; Keshelashvili, I.; Mchedlishvili, D.; JEDI Collaboration

    2017-11-01

    Four detector modules, built from three different LYSO crystals and two different types of light sensors (PMTs and SiPM arrays), have been tested with a deuteron beam from 100 MeV - 270 MeV at the COSY accelerator facility for the srEDM project at the Forschungszentrum Jülich in Germany. The detector modules were arranged in a cluster hand mounted on a positioning table. The deuteron beam was targeted at the center of each individual crystal for data analysis. The signals were digitized using a 14 bit, 250 MS/s flash ADC. Further, the energy spectra were calibrated using the known beam energies from the accelerator. From the calibrated spectra, the energy resolution was calculated. A resolution of 3% for the low energies and down to 1% for the high energy of 270 MeV was achieved. A deuteron reconstruction efficiency of almost 100% for low energies and around 70% for high energies was achieved. The SiPM light sensor showed a very good performance and will be used for the next generation of detector modules.

  10. The progress of test and study for steam dryer in vertical steam generator

    International Nuclear Information System (INIS)

    Ding Xunshen

    1993-01-01

    Constructions, tests and test results are reviewed for three types of steam generator dryer that are concentric vertical corrugated separator, centrifugal conic separator and chevron separator. The last type is considered as the best one in comparison, which has been applied to Qinshan 300 MW steam generator. A number of pertinent remarks to draining scheme, hydraulic loss reduction, and conduct of test are given based on experiences

  11. MR imaging of primary sclerosing cholangitis - Additional value of diffusion-weighted imaging and ADC measurement

    Energy Technology Data Exchange (ETDEWEB)

    Djokicc Kovac, Jelena [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia)], e-mail: jelenadjokic2003@yahoo.co.uk; Maksimovic, Ruzica [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Jesic, Rada [Clinic for Gastroenterohepatology, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Stanisavljevic, Dejana [Inst. for Statistics, Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Kovac, Bojan [Military Medical Academy, Belgrade (Serbia)

    2013-04-15

    Background: Primary sclerosing cholangitis (PSC) is a cholestatic liver disease with chronic inflammation and progressive destruction of biliary tree. Magnetic resonance (MR) examination with diffusion-weighted imaging (DWI) allows analysis of morphological liver parenchymal changes and non-invasive assessment of liver fibrosis. Moreover, MR cholangiopancreatography (MRCP), as a part of standard MR protocol, provides insight into bile duct irregularities. Purpose: To evaluate MR and MRCP findings in patients with primary sclerosing cholangitis and to determine the value of DWI in the assessment of liver fibrosis. Material and Methods: The following MR findings were reviewed in 38 patients: abnormalities in liver parenchyma signal intensity, changes in liver morphology, lymphadenopathy, signs of portal hypertension, and irregularities of intra- and extrahepatic bile ducts. Apparent diffusion coefficient (ADC) was calculated for six locations in the liver for b = 800 s/mm{sup 2}. Results: T2-weighted hyperintensity was seen as peripheral wedge-shaped areas in 42.1% and as periportal edema in 28.9% of patients. Increased enhancement of liver parenchyma on arterial-phase imaging was observed in six (15.8%) patients. Caudate lobe hypertrophy was present in 10 (26.3%), while spherical liver shape was noted in 7.9% of patients. Liver cirrhosis was seen in 34.2% of patients; the most common pattern was micronodular cirrhosis (61.5%). Other findings included lymphadenopathy (28.9%), signs of portal hypertension (36.7%), and bile duct irregularities (78.9%). The mean ADCs (x10{sup -3} mm{sup 2}/s) were significantly different at stage I vs. stages III and IV, and stage II vs. stage IV. No significant difference was found between stages II and III. For prediction of stage {>=}II and stage {>=}III, areas under receiver-operating characteristic curves were 0.891 and 0.887, respectively. Conclusion: MR with MRCP is a necessary diagnostic procedure for diagnosis of PSC and

  12. End-on radioisotope thermoelectric generator impact tests

    International Nuclear Information System (INIS)

    Reimus, M.A.H.; Hhinckley, J.E.

    1997-01-01

    The General-Purpose Heat Source (GPHS) provides power for space missions by transmitting the heat of [sup 238]Pu decay to an array of thermoelectric elements in a radioisotope thermoelectric generator (RTG). The modular GPHS design was developed to address both survivability during launch abort and return from orbit. The first two RTG Impact Tests were designed to provide information on the response of a fully loaded RTG to end-on impact against a concrete target. The results of these tests indicated that at impact velocities up to 57 m/s the converter shell and internal components protect the GPHS capsules from excessive deformation. At higher velocities, some of the internal components of the RTG interact with the GPHS capsules to cause excessive localized deformation and failure

  13. A high speed low power low offset dynamic comparator used in SHA-less pipelined ADC

    Science.gov (United States)

    Shubin, Liu; Zhangming, Zhu; Yintang, Yang; Lianxi, Liu

    2014-05-01

    A novel fully differential high speed high resolution low offset CMOS dynamic comparator has been implemented in the SMIC 0.18 μm process used for a sample-and-hold amplifier (SHA)-less pipelined analog-to-digital converters (ADC). Based on the analysis and optimization between delay time and offset, an enhanced reset architecture with transmission gate was introduced to speed up the comparison and reset procedure. Four inputs with two cross coupled differential pairs, reconstituted bias circuit for tail current transistor and common centroid layouts make the comparator more robust against mismatch and process variations. The simulation results demonstrate that the proposed design achieves 1 mV sensitivity at 2.2 GHz sampling rate with a power consumption of 510 μW, while the mean offset voltage is equal to 10.244 mV.

  14. TID Test Results for 4th Generation iPad(TradeMark)

    Science.gov (United States)

    Guertin, S. M.; Allen, G. R.; McClure, S. S.; LaBel, K. A.

    2013-01-01

    TID testing of 4th generation iPads is reported. Of iPad subsystems, results indicate that the charging circuitry and display drivers fail at lowest TID levels. Details of construction are investigated for additional testing of components.

  15. Large scale sodium-water reaction tests for Monju steam generators

    International Nuclear Information System (INIS)

    Sato, M.; Hiroi, H.; Hori, M.

    1976-01-01

    To demonstrate the safe design of the steam generator system of the prototype fast reactor Monju against the postulated large leak sodium-water reaction, a large scale test facility SWAT-3 was constructed. SWAT-3 is a 1/2.5 scale model of the Monju secondary loop on the basis of the iso-velocity modeling. Two tests have been conducted in SWAT-3 since its construction. The test items using SWAT-3 are discussed, and the description of the facility and the test results are presented

  16. Overview of the Division 2351 Neutron Generator Test Facility waveform digitizing system

    International Nuclear Information System (INIS)

    Bryant, T.C. Jr.

    1978-02-01

    All neutron generator waveforms from units tested at the SLA neutron generator test site are digitized and the digitized data stored in the CDC 6600 tape library for display and analysis using the CDC 6600 computer. The digitizing equipment consists mainly of seven Biomation Model 8100 transient recorders, Digital Equipment Corporation PDP 11/20 computer, RK05 disk, seven-track magnetic tape transport, and appropriate DEC and SLA controllers and interfaces. The PDP 11/20 computer is programmed in BASIC with assembly language drivers. In addition to digitizing waveforms, this equipment is used for other functions such as the automated testing of multiple-operation electronic neutron generators. Although other types of analysis have been done, the largest use of the digitized data has been for various types of graphical displays using the CDC 6600 and either the SD4020 or DX4460 plotters

  17. Path-Wise Test Data Generation Based on Heuristic Look-Ahead Methods

    Directory of Open Access Journals (Sweden)

    Ying Xing

    2014-01-01

    Full Text Available Path-wise test data generation is generally considered an important problem in the automation of software testing. In essence, it is a constraint optimization problem, which is often solved by search methods such as backtracking algorithms. In this paper, the backtracking algorithm branch and bound and state space search in artificial intelligence are introduced to tackle the problem of path-wise test data generation. The former is utilized to explore the space of potential solutions and the latter is adopted to construct the search tree dynamically. Heuristics are employed in the look-ahead stage of the search. Dynamic variable ordering is presented with a heuristic rule to break ties, values of a variable are determined by the monotonicity analysis on branching conditions, and maintaining path consistency is achieved through analysis on the result of interval arithmetic. An optimization method is also proposed to reduce the search space. The results of empirical experiments show that the search is conducted in a basically backtrack-free manner, which ensures both test data generation with promising performance and its excellence over some currently existing static and dynamic methods in terms of coverage. The results also demonstrate that the proposed method is applicable in engineering.

  18. Testing of the Advanced Stirling Radioisotope Generator Engineering Unit at NASA Glenn Research Center

    Science.gov (United States)

    Lewandowski, Edward J.

    2013-01-01

    The Advanced Stirling Radioisotope Generator (ASRG) is a high-efficiency generator being developed for potential use on a Discovery 12 space mission. Lockheed Martin designed and fabricated the ASRG Engineering Unit (EU) under contract to the Department of Energy. This unit was delivered to NASA Glenn Research Center in 2008 and has been undergoing extended operation testing to generate long-term performance data for an integrated system. It has also been used for tests to characterize generator operation while varying control parameters and system inputs, both when controlled with an alternating current (AC) bus and with a digital controller. The ASRG EU currently has over 27,000 hours of operation. This paper summarizes all of the tests that have been conducted on the ASRG EU over the past 3 years and provides an overview of the test results and what was learned.

  19. Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit

    Science.gov (United States)

    Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina

    2009-01-01

    The Advanced Stirling Radioisotope Generator (ASRG) is being considered to power deep space missions. An engineering unit, the ASRG-EU, was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently on an extended operation test at NASA Glenn Research Center to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for testing the ASRG-EU. Details of the test facility design are discussed. The facility can operate the convertors under AC bus control or with the ASRG-EU controller. It can regulate input thermal power in either a fixed temperature or fixed power mode. An enclosure circulates cooled air around the ASRG-EU to remove heat rejected from the ASRG-EU by convection. A custom monitoring and data acquisition system supports the test. Various safety features, which allow 2417 unattended operation, are discussed.

  20. An FPGA-based Sampling-ADC readout for the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Muellers, Johannes [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Marciniewski, Pawel [Angstroemlaboratoriet, Uppsala (Sweden); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    The CBELSA/TAPS experiment at the electron accelerator ELSA (Bonn) investigates the photoproduction of mesons off protons and neutrons. The Crystal Barrel Calorimeter has been upgraded replacing its photodiode readout by APDs, which allows the integration of the calorimeter into the first level trigger. Since the possible DAQ rate is currently limited by the digitization stage (LeCroy QDC1885F) to ∼ 2 kHz, the implementation of a new Sampling-ADC (SADC) readout is the second important step in the upgrade of the detector system. Based on the 64-channel PANDA-SADC, the design was modified, adapting it to the needs of the CBELSA/TAPS experiment. The CB-SADC offers 64 channels in one NIM module with up to 14 bit rate at 125 MHz, accompanied by a modular analog input stage and power supply. Data processing and reduction are realized with Kintex7 FPGAs. Readout is possible via gigabit ethernet links. Using an FPGA provides a multitude of possibilities for online feature extraction, such as the determination of the energy deposited in the crystal, TDC capabilities and pile-up detection and recovery. The SADC development is discussed, and first measurements performed in comparison to the presently used LeCroy QDC are presented.

  1. Evaluating an Automated Number Series Item Generator Using Linear Logistic Test Models

    Directory of Open Access Journals (Sweden)

    Bao Sheng Loe

    2018-04-01

    Full Text Available This study investigates the item properties of a newly developed Automatic Number Series Item Generator (ANSIG. The foundation of the ANSIG is based on five hypothesised cognitive operators. Thirteen item models were developed using the numGen R package and eleven were evaluated in this study. The 16-item ICAR (International Cognitive Ability Resource1 short form ability test was used to evaluate construct validity. The Rasch Model and two Linear Logistic Test Model(s (LLTM were employed to estimate and predict the item parameters. Results indicate that a single factor determines the performance on tests composed of items generated by the ANSIG. Under the LLTM approach, all the cognitive operators were significant predictors of item difficulty. Moderate to high correlations were evident between the number series items and the ICAR test scores, with high correlation found for the ICAR Letter-Numeric-Series type items, suggesting adequate nomothetic span. Extended cognitive research is, nevertheless, essential for the automatic generation of an item pool with predictable psychometric properties.

  2. Optimal Sequential Diagnostic Strategy Generation Considering Test Placement Cost for Multimode Systems

    Directory of Open Access Journals (Sweden)

    Shigang Zhang

    2015-10-01

    Full Text Available Sequential fault diagnosis is an approach that realizes fault isolation by executing the optimal test step by step. The strategy used, i.e., the sequential diagnostic strategy, has great influence on diagnostic accuracy and cost. Optimal sequential diagnostic strategy generation is an important step in the process of diagnosis system construction, which has been studied extensively in the literature. However, previous algorithms either are designed for single mode systems or do not consider test placement cost. They are not suitable to solve the sequential diagnostic strategy generation problem considering test placement cost for multimode systems. Therefore, this problem is studied in this paper. A formulation is presented. Two algorithms are proposed, one of which is realized by system transformation and the other is newly designed. Extensive simulations are carried out to test the effectiveness of the algorithms. A real-world system is also presented. All the results show that both of them have the ability to solve the diagnostic strategy generation problem, and they have different characteristics.

  3. Optimal Sequential Diagnostic Strategy Generation Considering Test Placement Cost for Multimode Systems

    Science.gov (United States)

    Zhang, Shigang; Song, Lijun; Zhang, Wei; Hu, Zheng; Yang, Yongmin

    2015-01-01

    Sequential fault diagnosis is an approach that realizes fault isolation by executing the optimal test step by step. The strategy used, i.e., the sequential diagnostic strategy, has great influence on diagnostic accuracy and cost. Optimal sequential diagnostic strategy generation is an important step in the process of diagnosis system construction, which has been studied extensively in the literature. However, previous algorithms either are designed for single mode systems or do not consider test placement cost. They are not suitable to solve the sequential diagnostic strategy generation problem considering test placement cost for multimode systems. Therefore, this problem is studied in this paper. A formulation is presented. Two algorithms are proposed, one of which is realized by system transformation and the other is newly designed. Extensive simulations are carried out to test the effectiveness of the algorithms. A real-world system is also presented. All the results show that both of them have the ability to solve the diagnostic strategy generation problem, and they have different characteristics. PMID:26457709

  4. Application of a path sensitizing method on automated generation of test specifications for control software

    International Nuclear Information System (INIS)

    Morimoto, Yuuichi; Fukuda, Mitsuko

    1995-01-01

    An automated generation method for test specifications has been developed for sequential control software in plant control equipment. Sequential control software can be represented as sequential circuits. The control software implemented in a control equipment is designed from these circuit diagrams. In logic tests of VLSI's, path sensitizing methods are widely used to generate test specifications. But the method generates test specifications at a single time only, and can not be directly applied to sequential control software. The basic idea of the proposed method is as follows. Specifications of each logic operator in the diagrams are defined in the software design process. Therefore, test specifications of each operator in the control software can be determined from these specifications, and validity of software can be judged by inspecting all of the operators in the logic circuit diagrams. Candidates for sensitized paths, on which test data for each operator propagates, can be generated by the path sensitizing method. To confirm feasibility of the method, it was experimentally applied to control software in digital control equipment. The program could generate test specifications exactly, and feasibility of the method was confirmed. (orig.) (3 refs., 7 figs.)

  5. Some failures of diesel generators during commissioning tests of 1300 MWe PWR

    International Nuclear Information System (INIS)

    Colas, A.F.; Morzelle, C.

    1985-10-01

    During commissioning tests of the French 1300 MWe units, which are equipped with different diesel generator from the 900 MWe units, some devices and components failures were experienced. These components include: Alarm sensors on fuel, lubricating, cooling circuits; Injection pumps and speed governors; Fuel delivery; Vibrations of fuel and lubrication lines. This paper shows how and when the above elements can affect the reliability of Diesel-generator units and how commissioning tests should show the defects

  6. Wind Generators Test Bench. Optimal Design of PI Controller

    Directory of Open Access Journals (Sweden)

    TUDORACHE, T.

    2011-08-01

    Full Text Available This paper proposes a novel and robust strategy for the optimal design of the drive system integrated in a wind generators test bench. The PI regulator coefficients used in control systems are usually computed based on simplified hypotheses and then tuned manually so as the system response meet certain specifications in terms of stability, accuracy and speed. The proposed methodology permits the automatic identification of PI regulator coefficients using intelligent optimization algorithms, the initial guess for the search procedure being determined based on particular simplified hypotheses. The proposed procedure can help the design engineers to drastically reduce the effort for finding the best PI regulator coefficients offering a range of feasible solutions depending on the imposed optimum criteria. The characteristics and performances of the optimization strategy are highlighted by using it for the design of a DC motor drive system used to simulate the wind prime mover integrated in a wind generators test bench.

  7. Radioisotope thermoelectric generator/thin fragment impact test

    International Nuclear Information System (INIS)

    Reimus, M.A.H.; Hinckley, J.E.

    1998-01-01

    The General-Purpose Heat Source (GPHS) provides power for space missions by transmitting the heat of 238 Pu decay to an array of thermoelectric elements in a radioisotope thermoelectric generator (RTG). Because the potential for a launch abort or return from orbit exists for any space mission, the heat source response to credible accident scenarios is being evaluated. This test was designed to provide information on the response of a loaded RTG to impact by a fragment similar to the type of fragment produced by breakup of the spacecraft propulsion module system (PMS). The results of this test indicated that impact of the RTG by a thin aluminum fragment traveling at 306 m/s may result in significant damage to the convertor housing, failure of one fueled clad, and release of a small quantity of fuel

  8. Some failures of diesel-generators during commissioning tests of 1300 MWe PWR

    International Nuclear Information System (INIS)

    Colas, A.F.; Morzelle, C.

    1986-01-01

    During commissioning tests of the French 1300 MWe units, which are equipped with different diesel generator from the 900 MWe units, some devices and components failures were experienced. These components include: - Alarm sensors on fuel, lubricating, cooling circuits. - Injection pumps and speed governors. - Fuel delivery. - Vibrations of fuel and lubrication lines. This paper will try to show how and when the above elements can affect the reliability of Diesel-generator units and how commissioning tests should show the defects. (authors)

  9. Some failures of diesel-generators during commissioning tests of 1300 MWe PWR

    Energy Technology Data Exchange (ETDEWEB)

    Colas, A. F. [Commissariat a l' Energie Atomique, Institut de Protection et Surete Nucleaire, Departement d' Analyse de Surete, CEA/IPSN, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, B.P. No. 6, 92260 Fontenay-aux-Roses (France); Morzelle, C. [Service Etudes et Projets Thermiques et Nucleaires, EdF Lyon (France)

    1986-02-15

    During commissioning tests of the French 1300 MWe units, which are equipped with different diesel generator from the 900 MWe units, some devices and components failures were experienced. These components include: - Alarm sensors on fuel, lubricating, cooling circuits. - Injection pumps and speed governors. - Fuel delivery. - Vibrations of fuel and lubrication lines. This paper will try to show how and when the above elements can affect the reliability of Diesel-generator units and how commissioning tests should show the defects. (authors)

  10. Multifrequency eddy current testing of helical tubes of steam generators

    International Nuclear Information System (INIS)

    Pigeon, M.; David, B.

    1983-06-01

    In the event of a water-sodium reaction in a steam-generator of a fast breeder reactor, it is necessary to test the tubes close to the leak to evaluate the damage. In SUPERPHENIX, the tubes are about 100m long and are coiled on a dead body. This report describes the equipment and the technic to test such tubes with multifrequency eddy current technics [fr

  11. COTRANSA simulation of Chinshan unit one generator load rejection test

    International Nuclear Information System (INIS)

    Wu, C.H.

    1984-01-01

    A simulation of the plant behavior during a BWR generator load rejection transient using Exxon Nuclear Company's COTRANSA code is presented in this paper. The results are compared to measurements obtained by Taiwan Power Company during a generator load rejection transient, initiated at full power condition, which was one of the Chinshan Unit 1 initial cycle startup tests. Good agreement between the COTRANSA predicted and the measured values, indicates that the COTRANSA code can simulate this transient satisfactorily

  12. Real time testing of intelligent relays for synchronous distributed generation islanding detection

    Science.gov (United States)

    Zhuang, Davy

    As electric power systems continue to grow to meet ever-increasing energy demand, their security, reliability, and sustainability requirements also become more stringent. The deployment of distributed energy resources (DER), including generation and storage, in conventional passive distribution feeders, gives rise to integration problems involving protection and unintentional islanding. Distributed generators need to be islanded for safety reasons when disconnected or isolated from the main feeder as distributed generator islanding may create hazards to utility and third-party personnel, and possibly damage the distribution system infrastructure, including the distributed generators. This thesis compares several key performance indicators of a newly developed intelligent islanding detection relay, against islanding detection devices currently used by the industry. The intelligent relay employs multivariable analysis and data mining methods to arrive at decision trees that contain both the protection handles and the settings. A test methodology is developed to assess the performance of these intelligent relays on a real time simulation environment using a generic model based on a real-life distribution feeder. The methodology demonstrates the applicability and potential advantages of the intelligent relay, by running a large number of tests, reflecting a multitude of system operating conditions. The testing indicates that the intelligent relay often outperforms frequency, voltage and rate of change of frequency relays currently used for islanding detection, while respecting the islanding detection time constraints imposed by standing distributed generator interconnection guidelines.

  13. Assessing children's inference generation: what do tests of reading comprehension measure?

    Science.gov (United States)

    Bowyer-Crane, Claudine; Snowling, Margaret J

    2005-06-01

    Previous research suggests that children with specific comprehension difficulties have problems with the generation of inferences. This raises important questions as to whether poor comprehenders have poor comprehension skills generally, or whether their problems are confined to specific inference types. The main aims of the study were (a) using two commonly used tests of reading comprehension to classify the questions requiring the generation of inferences, and (b) to investigate the relative performance of skilled and less-skilled comprehenders on questions tapping different inference types. The performance of 10 poor comprehenders (mean age 110.06 months) was compared with the performance of 10 normal readers (mean age 112.78 months) on two tests of reading comprehension. A qualitative analysis of the NARA II (form 1) and the WORD comprehension subtest was carried out. Participants were then administered the NARA II, WORD comprehension subtest and a test of non-word reading. The NARA II was heavily reliant on the generation of knowledge-based inferences, while the WORD comprehension subtest was biased towards the retention of literal information. Children identified by the NARA II as having comprehension difficulties performed in the normal range on the WORD comprehension subtests. Further, children with comprehension difficulties performed poorly on questions requiring the generation of knowledge-based and elaborative inferences. However, they were able to answer questions requiring attention to literal information or use of cohesive devices at a level comparable to normal readers. Different reading tests tap different types of inferencing skills. Lessskilled comprehenders have particular difficulty applying real-world knowledge to a text during reading, and this has implications for the formulation of effective intervention strategies.

  14. Test of a high resolution drift chamber prototype

    International Nuclear Information System (INIS)

    Comminchau, V.; Deutschmann, M.; Draheim, K.J.; Fritze, P.; Hangarter, K.; Hawelka, P.; Herten, U.; Tonutti, M.; Anderhub, H.; Fehlmann, J.; Hofer, H.; Klein, M.; Paradiso, J.A.; Schreiber, J.; Viertel, G.

    1984-06-01

    The performance of a drift chamber prototype for a colliding beam vertex detector in a test beam at DESY is described. At one (two) atmosphere gas pressure a spatial resolution of 40 μm (30 μm) per wire for one cm drift length was achieved with a 100 MHz Flash-ADC system. An excellent double track resolution of better than 300 μm over the full drift length of 5 cm can be estimated. (orig.)

  15. Measurement Of Neutron Radius In Lead By Parity Violating Scattering Flash ADC DAQ

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Zafar [Christopher Newport Univ., Newport News, VA (United States)

    2012-06-01

    This dissertation reports the experiment PREx, a parity violation experiment which is designed to measure the neutron radius in 208Pb. PREx is performed in hall A of Thomas Jefferson National Accelerator Facility from March 19th to June 21st. Longitudionally polarized electrons at energy 1 GeV scattered at and angle of θlab = 5.8 ° from the Lead target. Beam corrected pairty violaing counting rate asymmetry is (Acorr= 594 ± 50(stat) ± 9(syst))ppb at Q2 = 0.009068GeV 2. This dissertation also presents the details of Flash ADC Data Acquisition(FADC DAQ) system for Moller polarimetry in Hall A of Thomas Jefferson National Accelerator Facility. The Moller polarimeter measures the beam polarization to high precision to meet the specification of the PREx(Lead radius experiment). The FADC DAQ is part of the upgrade of Moller polarimetery to reduce the systematic error for PREx. The hardware setup and the results of the FADC DAQ analysis are presented

  16. Approaches to informed consent for hypothesis-testing and hypothesis-generating clinical genomics research.

    Science.gov (United States)

    Facio, Flavia M; Sapp, Julie C; Linn, Amy; Biesecker, Leslie G

    2012-10-10

    Massively-parallel sequencing (MPS) technologies create challenges for informed consent of research participants given the enormous scale of the data and the wide range of potential results. We propose that the consent process in these studies be based on whether they use MPS to test a hypothesis or to generate hypotheses. To demonstrate the differences in these approaches to informed consent, we describe the consent processes for two MPS studies. The purpose of our hypothesis-testing study is to elucidate the etiology of rare phenotypes using MPS. The purpose of our hypothesis-generating study is to test the feasibility of using MPS to generate clinical hypotheses, and to approach the return of results as an experimental manipulation. Issues to consider in both designs include: volume and nature of the potential results, primary versus secondary results, return of individual results, duty to warn, length of interaction, target population, and privacy and confidentiality. The categorization of MPS studies as hypothesis-testing versus hypothesis-generating can help to clarify the issue of so-called incidental or secondary results for the consent process, and aid the communication of the research goals to study participants.

  17. Field testing of a 1,300MVA turbine generator for the Oi nuclear-power station

    International Nuclear Information System (INIS)

    Inoue, Toshiaki; Tajiri, Yoshiaki; Ito, Hiroyuki; Fukuda, Mitsuo.

    1980-01-01

    The first Mitsubishi 1,300MVA turbine generator for this power station was put into commercial operation in March 1979, and the second unit in December of that year. The turbine generators use new technology in a variety of areas, including the cooling system, to achieve great increases in capacity over previously designed generators, and are destined to become the worldwide standard for large-scale generators of this type. Valuable experience was gained in the installation and testing of the generators. The outline of the tests performed on the generators with respect to heating and vibration are described in the article. (author)

  18. Acceptance Test Plan for Fourth-Generation Corrosion Monitoring Cabinet

    International Nuclear Information System (INIS)

    NORMAN, E.C.

    2000-01-01

    This Acceptance Test Plan (ATP) will document the satisfactory operation of the third-generation corrosion monitoring cabinet (Hiline Engineering Part No.0004-CHM-072-C01). This ATP will be performed by the manufacturer of the cabinet prior to delivery to the site. The objective of this procedure is to demonstrate and document the acceptance of the corrosion monitoring cabinet. The test will consist of a continuity test of the cabinet wiring from the end of cable to be connected to corrosion probe, through the appropriate intrinsic safety barriers and out to the 15 pin D-shell connectors to be connected to the corrosion monitoring instrument. Additional testing will be performed using a constant current and voltage source provided by the corrosion monitoring hardware manufacturer to verify proper operation of corrosion monitoring instrumentation

  19. NREL-Prime Next-Generation Drivetrain Dynamometer Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Erdman, Bill [Cinch, Inc., Moraga, CA (United States); Blodgett, Douglas [DNV KEMA Renewables, Burlington, VT (United States); Halse, Christopher [Romax Technology, Boulder, CO (United States)

    2016-08-01

    Advances in wind turbine drivetrain technologies are necessary to improve reliability and reduce the cost of energy for land-based and offshore wind turbines. The NREL-Prime Next-Generation Drivetrain team developed a geared, medium-speed drivetrain that is lighter, more reliable and more efficient than existing designs. One of the objectives of Phase II of the project was to complete the detailed design, fabrication, and dynamometer testing of a 750 kilowatt (kW) drivetrain that includes the key gearbox innovations designed by Romax Technology and power converter innovations designed by DNV Kema Renewables. The purpose of this document is to summarize these tests completed in NREL's National Wind Technology Center 2.5 megawatt (MW) dynamometer.

  20. Acceptance test for 900 MWe PWR unit replacement steam generators

    International Nuclear Information System (INIS)

    Gourguechon, B.

    1993-01-01

    During the first half of 1994, the Gravelines 1 steam generators will be replaced (SG replacement procedure). The new SG's differ from the former components notably by the alloy used for the tube bundle, in this case, the high chromium content Inconel 690. So, from this standpoint, they are to be considered as PWR 900 replacement SG first models and their thermal efficiency has consequently to be assessed. This will provide an opportunity of ensuring that the performance of the components delivered is in compliance with requirements and of making the necessary provisions if significant deviations are observed. The EFMT branch, which has been in charge of the instrumentation and acceptance of the different SG first models since the first PWR plants were commissioned, will be responsible for the acceptance tests and the ultimate validation of a performance assessment procedure applicable to the future replacement steam generators. The methods and tests proposed for SG expert appraisal are based on consideration of the importance of primary measurement quality for satisfactory SG assessment and of the new test facilities with which the 900 and 1 300 PWR plants are gradually being equipped. These facilities provide an on-site computer environment for tests compatible with the tools (PATTERN, etc.) used at EFMT and in other departments. This test is the first of this kind performed by EFMT and the test facility of a nuclear power plant. (author). 6 figs

  1. Summary of results from sodium-heated steam generator test program

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, J S

    1975-07-01

    A 28 MWt sodium-heated steam generator test unit developed and fabricated by Atomics International was operated in the Sodium Component Test Installation. The SCTI is located at the Liquid Metal Engineering Center which is operated for the Atomic Energy Commission by Atomics International, Reviewed in this paper are the results of the test operations and the findings of the post-test examination of the module. Testing was performed to assure the mechanical integrity of the unit over a wide range of simulated plant operating conditions and to develop a variety of performance data. Specific tests conducted included preheat, vibration, startup-shutdown, pressurization, steady state and parametric performance mapping, endurance, simulated leak injection, low- flow stability and simulated plant transients. (author)

  2. Automatic Generation of Tests from Domain and Multimedia Ontologies

    Science.gov (United States)

    Papasalouros, Andreas; Kotis, Konstantinos; Kanaris, Konstantinos

    2011-01-01

    The aim of this article is to present an approach for generating tests in an automatic way. Although other methods have been already reported in the literature, the proposed approach is based on ontologies, representing both domain and multimedia knowledge. The article also reports on a prototype implementation of this approach, which…

  3. Flame generation of sodium chloride aerosol for filter testing

    International Nuclear Information System (INIS)

    Edwards, J.; Kinnear, D.I.

    1975-01-01

    A generator for sodium chloride aerosol is described, which when used in conjunction with a sensitive portable sodium flame detector unit, will permit the in-place testing of large filter installations having air throughputs up to about 80,000 m 3 /h, at penetrations down to at least 0.005 percent. (U.S.)

  4. Artificial Neural Network as the FPGA Trigger in the Cyclone V based Front-End for a Detection of Neutrino-Origin Showers

    Energy Technology Data Exchange (ETDEWEB)

    Szadkowski, Zbigniew; Glas, Dariusz [University of Lodz, Department of Physics and Applied Informatics, Faculty of High-Energy Astrophysics, 90-236 Lodz, Pomorska 149 (Poland); Pytel, Krzysztof [University of Lodz, Department of Physics and Applied Informatics, Faculty of Informatics, 90-236 Lodz (Poland)

    2015-07-01

    Neutrinos play a fundamental role in the understanding of the origin of ultra-high-energy cosmic rays. They interact through charged and neutral currents in the atmosphere generating extensive air showers. However, their a very low rate of events potentially generated by neutrinos is a significant challenge for a detection technique and requires both sophisticated algorithms and high-resolution hardware. A trigger based on a artificial neural network was implemented into the Cyclone{sup R} V E FPGA 5CEFA9F31I7 - the heart of the prototype Front-End boards developed for tests of new algorithms in the Pierre Auger surface detectors. Showers for muon and tau neutrino initiating particles on various altitudes, angles and energies were simulated in CORSICA and Offline platforms giving pattern of ADC traces in Auger water Cherenkov detectors. The 3-layer 12-8-1 neural network was taught in MATLAB by simulated ADC traces according the Levenberg-Marquardt algorithm. Results show that a probability of a ADC traces generation is very low due to a small neutrino cross-section. Nevertheless, ADC traces, if occur, for 1-10 EeV showers are relatively short and can be analyzed by 16-point input algorithm. We optimized the coefficients from MATLAB to get a maximal range of potentially registered events and for fixed-point FPGA processing to minimize calculation errors. New sophisticated triggers implemented in Cyclone{sup R} V E FPGAs with large amount of DSP blocks, embedded memory running with 120 - 160 MHz sampling may support a discovery of neutrino events in the Pierre Auger Observatory. (authors)

  5. The value of multi ultra high-b-value DWI in grading cerebral astrocytomas and its association with aquaporin-4.

    Science.gov (United States)

    Tan, Yan; Zhang, Hui; Wang, Xiao-Chun; Qin, Jiang-Bo; Wang, Le

    2018-06-01

    To investigate the value of multi-ultrahigh-b-value diffusion-weighted imaging (UHBV-DWI) in differentiating high-grade astrocytomas (HGAs) from low-grade astrocytomas (LGAs), analyze its association with aquaporin (AQP) expression. 40 astrocytomas divided into LGAs (N = 15) and HGAs (N = 25) were studied. Apparent diffusion coefficient (ADC) and UHBV-ADC values in solid parts and peritumoral edema were compared between LGAs and HGAs groups by the t-test. Using receiver operating characteristic curves to identify the better parameter. Using real time polymerase chain reaction to assess AQP messenger ribonucleic acid (mRNA). Using spearman correlation analysis to assess the correlation of AQP mRNA with each parameter. ADC values in solid parts of HGAs were significantly lower than LGAs (p = 0.02), while UHBV-ADC values of HGAs were significantly higher than LGAs (p  0.05); ADC value showed a negative correlation with AQP4 mRNA (r = -0.357; p = 0.024). UHBV-ADC value positively correlated with the AQP4 mRNA (r = 0.646; p value may be related with the AQP4 mRNA levels. UHBV-DWI could be of value in the assessment of astrocytoma. Advances in knowledge: UHBV-DWI generated by multi UHBV could have particular value for astrocytoma grading, and the level of AQP4 mRNA might be potentially linked to the change of UHBV-DWI parameter, and we might find the exact reason for the difference of UHBV-ADC between the LGAs and HGAs.

  6. A 5bit 1GS/s 2.7mW 0.05mm^2 asynchronous digital slope ADC in 90nm CMOS for IR UWB radio

    NARCIS (Netherlands)

    Ding, M.; Harpe, P.J.A.; Hegt, J.A.; Philips, K.J.P.; Groot, de H.W.H.; Roermund, van A.H.M.

    2012-01-01

    A 5bit 1GS/s 0.05mm2 4× time-interleaved asynchronous digital slope ADC in 90nm CMOS for IR UWB radio is presented. New delay cells are introduced to double the speed over prior art, yielding the 250MS/s single-channel slope converter. A self-disabled comparator eliminates static leakage and

  7. Generation of Test Questions from RDF Files Using PYTHON and SPARQL

    Science.gov (United States)

    Omarbekova, Assel; Sharipbay, Altynbek; Barlybaev, Alibek

    2017-02-01

    This article describes the development of the system for the automatic generation of test questions based on the knowledge base. This work has an applicable nature and provides detailed examples of the development of ontology and implementation the SPARQL queries in RDF-documents. Also it describes implementation of the program generating questions in the Python programming language including the necessary libraries while working with RDF-files.

  8. Humans can consciously generate random number sequences: a possible test for artificial intelligence.

    Science.gov (United States)

    Persaud, Navindra

    2005-01-01

    Computer algorithms can only produce seemingly random or pseudorandom numbers whereas certain natural phenomena, such as the decay of radioactive particles, can be utilized to produce truly random numbers. In this study, the ability of humans to generate random numbers was tested in healthy adults. Subjects were simply asked to generate and dictate random numbers. Generated numbers were tested for uniformity, independence and information density. The results suggest that humans can generate random numbers that are uniformly distributed, independent of one another and unpredictable. If humans can generate sequences of random numbers then neural networks or forms of artificial intelligence, which are purported to function in ways essentially the same as the human brain, should also be able to generate sequences of random numbers. Elucidating the precise mechanism by which humans generate random number sequences and the underlying neural substrates may have implications in the cognitive science of decision-making. It is possible that humans use their random-generating neural machinery to make difficult decisions in which all expected outcomes are similar. It is also possible that certain people, perhaps those with neurological or psychiatric impairments, are less able or unable to generate random numbers. If the random-generating neural machinery is employed in decision making its impairment would have profound implications in matters of agency and free will.

  9. The Test-Retest Reliability of New Generation Power Indices of Wingate All-Out Test

    Directory of Open Access Journals (Sweden)

    Ozgur Ozkaya

    2018-04-01

    Full Text Available Although reliability correlations of traditional power indices of the Wingate test have been well documented, no study has analyzed new generation power indices based on milliseconds obtained from a Peak Bike. The purpose of this study was to investigate the retest reliability of new generation power indices. Thirty-two well-trained male athletes who were specialized in basketball, football, tennis, or track and field volunteered to take part in the study (age: 24.3 ± 2.2 years; body mass: 77 ± 8.3 kg; height: 180.3 ± 6.3 cm. Participants performed two Wingate all-out sessions on two separate days. Intra-class correlation coefficient (ICC, standard error measurement (SEM, smallest real differences (SRD and coefficient of variation (CV scores were analyzed based on the test and retest data. Reliability results of traditional power indices calculated based on 5-s means such as peak power, average power, power drop, and fatigue index ratio were similar with the previous findings in literature (ICC ≥ 0.94; CV ≤ 2.8%; SEM ≤ 12.28; SRD% ≤ 7.7%. New generation power indices such as peak power, average power, lowest power, power drop, fatigue index, power decline, maximum speed as rpm, and amount of total energy expenditure demonstrated high reliability (ICC ≥ 0.94; CV ≤ 4.3%; SEM ≤ 10.36; SRD% ≤ 8.8%. Time to peak power, time at maximum speed, and power at maximum speed showed a moderate level of reliability (ICC ≥ 0.73; CV ≤ 8.9%; SEM ≤ 63.01; SRD% ≤ 22.4%. The results of this study indicate that reliability correlations and SRD% of new generation power and fatigue-related indices are similar with traditional 5-s means. However, new time-related indices are very sensitive and moderately reliable.

  10. US/USSR cooperative program in open-cycle MHD electrical power gneration. Joint test report No. 2: tests in the U-25B facility; MHD generator test No. 3

    International Nuclear Information System (INIS)

    Tempelmeyer, K.E.; Sokolov, Y.N.

    1979-04-01

    The third joint test with a Soviet U-25B MHD generator and a US superconducting magnet system (SCMS) was conducted in the Soviet U-25B Facility. The primary objectives of the 3rd test were: (1) to operate the facility and MHD channel over a wider range of test parameters, and (2) to study the performance of all components and systems of the flow train at increased mass flow rates of combustion products (up to 4 kg/s), at high magnetic-field induction (up to 5 T), and high values of the electrical field in the MHD generator. The third test has demonstrated that all components and systems of the U-25B facility performed reliably. The electric power generated by the MHD generaor reached a maximum of 575 kW during this test. The MHD generator was operated under electrical loading conditions for 9 hours, and the combustor for a total of approximately 14 hours. Very high Hall fields (2.1 kV/m) were produced in the MHD channel, with a total Hall voltage of 4.24 kV. A detailed description is given of (1) performance of all components and systems of the U-25B facility, (2) analysis of the thermal, gasdynamic, and electrical characteristics of the MHD generator, (3) results of plasma diagnostic studies, (4) studies of vibrational characteristics of the flow train, (5) fluctuation of electrodynamic and gasdynamic parameters, (6) interaction of the MHD generator with the superconducting magnet, and (7) an operational problem, which terminated the test

  11. Mixed-Signal Hardware Security: Attacks and Countermeasures for ΔΣ ADC

    Directory of Open Access Journals (Sweden)

    Shayan Taheri

    2017-08-01

    Full Text Available Mixed-signal integrated circuits (ICs play an eminent and critical role in design and development of the embedded systems leveraged within smart weapons and military systems. These ICs can be a golden target for adversaries to compromise in order to function maliciously. In this work, we study the security aspects of a tunnel field effect transistor (TFET-based first-order one-bit delta-sigma ( Δ Σ analog to digital converter (ADC through proposing four attack and one defense models. The first attack manipulates the input signal to the Δ Σ modulator. The second attack manipulates the analog version of the modulator output bit and is triggered by the noise signal. The third attack manipulates the modulator output bit and has a controllable trigger mechanism. The fourth attack manipulates the analog version of the modulator output bit and is triggered by a victim capacitance within the chip. For the defense, a number of signal processing filters are used in order to purge the analog version of the modulator output bit for elimination of the malicious unwanted features, introduced by the attacks. According to the simulation results, the second threat model displays the strongest attack. Derived from the countermeasure evaluation, the best filter to confront the threat models is the robust regression using the least absolute residual computing method.

  12. DCT Trigger in a High-Resolution Test Platform for the Detection of Very Inclined Showers in Pierre Auger Surface Detectors

    Science.gov (United States)

    Szadkowski, Zbigniew; Wiedeński, Michał

    2017-06-01

    We present first results from a trigger based on the discrete cosine transform (DCT) operating in new front-end boards with a Cyclone V E field-programmable gate array (FPGA) deployed in seven test surface detectors in the Pierre Auger Test Array. The patterns of the ADC traces generated by very inclined showers (arriving at 70° to 90° from the vertical) were obtained from the Auger database and from the CORSIKA simulation package supported by the Auger OffLine event reconstruction platform that gives predicted digitized signal profiles. Simulations for many values of the initial cosmic ray angle of arrival, the shower initialization depth in the atmosphere, the type of particle, and its initial energy gave a boundary on the DCT coefficients used for the online pattern recognition in the FPGA. Preliminary results validated the approach used. We recorded several showers triggered by the DCT for 120 Msamples/s and 160 Msamples/s.

  13. Design and test of a 10kW ORC supersonic turbine generator

    Science.gov (United States)

    Seume, J. R.; Peters, M.; Kunte, H.

    2017-03-01

    Manufactures are searching for possibilities to increase the efficiency of combustion engines by using the remaining energy of the exhaust gas. One possibility to recover some of this thermal energy is an organic Rankine cycle (ORC). For such an ORC running with ethanol, the aerothermodynamic design and test of a supersonic axial, single stage impulse turbine generator unit is described. The blade design as well as the regulation by variable partial admission is shown. Additionally the mechanical design of the directly coupled turbine generator unit including the aerodynamic sealing and the test facility is presented. Finally the results of CFD-based computations are compared to the experimental measurements. The comparison shows a remarkably good agreement between the numerical computations and the test data.

  14. Subtype Differentiation of Small (≤ 4 cm) Solid Renal Mass Using Volumetric Histogram Analysis of DWI at 3-T MRI.

    Science.gov (United States)

    Li, Anqin; Xing, Wei; Li, Haojie; Hu, Yao; Hu, Daoyu; Li, Zhen; Kamel, Ihab R

    2018-05-29

    The purpose of this article is to evaluate the utility of volumetric histogram analysis of apparent diffusion coefficient (ADC) derived from reduced-FOV DWI for small (≤ 4 cm) solid renal mass subtypes at 3-T MRI. This retrospective study included 38 clear cell renal cell carcinomas (RCCs), 16 papillary RCCs, 18 chromophobe RCCs, 13 minimal fat angiomyolipomas (AMLs), and seven oncocytomas evaluated with preoperative MRI. Volumetric ADC maps were generated using all slices of the reduced-FOV DW images to obtain histogram parameters, including mean, median, 10th percentile, 25th percentile, 75th percentile, 90th percentile, and SD ADC values, as well as skewness, kurtosis, and entropy. Comparisons of these parameters were made by one-way ANOVA, t test, and ROC curves analysis. ADC histogram parameters differentiated eight of 10 pairs of renal tumors. Three subtype pairs (clear cell RCC vs papillary RCC, clear cell RCC vs chromophobe RCC, and clear cell RCC vs minimal fat AML) were differentiated by mean ADC. However, five other subtype pairs (clear cell RCC vs oncocytoma, papillary RCC vs minimal fat AML, papillary RCC vs oncocytoma, chromophobe RCC vs minimal fat AML, and chromophobe RCC vs oncocytoma) were differentiated by histogram distribution parameters exclusively (all p histogram parameters yielded the highest AUC (0.851; sensitivity, 80.0%; specificity, 86.1%). Quantitative volumetric ADC histogram analysis may help differentiate various subtypes of small solid renal tumors, including benign and malignant lesions.

  15. Waste generation and pollution prevention progress fact sheet: Nevada Test Site

    International Nuclear Information System (INIS)

    1994-01-01

    The Nevada Test Site is responsible for maintaining nuclear testing capability, supporting science-based Stockpile Stewardship experiments, maintaining nuclear agency response capability, applying environmental restoration techniques to areas affected by nuclear testing, managing low-level and mixed radioactive waste, investigating demilitarization technologies, investigating counter- proliferation technologies, supporting work-for-others programs and special Department of Defense activities, operating a hazardous materials spill test center, and providing for the commercial development of the site. This fact sheet provides information on routine waste generation and projected reduction by waste type. Also, materials recycled by the Nevada Test Site in 1994 are listed

  16. Instructional Topics in Educational Measurement (ITEMS) Module: Using Automated Processes to Generate Test Items

    Science.gov (United States)

    Gierl, Mark J.; Lai, Hollis

    2013-01-01

    Changes to the design and development of our educational assessments are resulting in the unprecedented demand for a large and continuous supply of content-specific test items. One way to address this growing demand is with automatic item generation (AIG). AIG is the process of using item models to generate test items with the aid of computer…

  17. Investigation, Analysis, and Testing of Self-contained Oxygen Generators

    Science.gov (United States)

    Keddy, Christopher P.; Haas, Jon P.; Starritt, Larry

    2008-01-01

    Self Contained Oxygen Generators (SCOGs) have widespread use in providing emergency breathing oxygen in a variety of environments including mines, submarines, spacecraft, and aircraft. These devices have definite advantages over storing of gaseous or liquid oxygen. The oxygen is not generated until a chemical briquette containing a chlorate or perchlorate oxidizer and a solid metallic fuel such as iron is ignited starting a thermal decomposition process allowing gaseous oxygen to be produced. These devices are typically very safe to store, easy to operate, and have primarily only a thermal hazard to the operator that can be controlled by barriers or furnaces. Tens of thousands of these devices are operated worldwide every year without major incident. This report examines the rare case of a SCOG whose behavior was both abnormal and lethal. This particular type of SCOG reviewed is nearly identical to a flight qualified version of SCOG slated for use on manned space vehicles. This Investigative Report is a compilation of a NASA effort in conjunction with other interested parties including military and aerospace to understand the causes of the particular SCOG accident and what preventative measures can be taken to ensure this incident is not repeated. This report details the incident and examines the root causes of the observed SCOG behavior from forensic evidence. A summary of chemical and numerical analysis is provided as a background to physical testing of identical SCOG devices. The results and findings of both small scale and full scale testing are documented on a test-by-test basis along with observations and summaries. Finally, conclusions are presented on the findings of this investigation, analysis, and testing along with suggestions on preventative measures for any entity interested in the safe use of these devices.

  18. T3i: A Tool for Generating and Querying Test Suites for Java

    NARCIS (Netherlands)

    Prasetya, I.S.W.B.

    2015-01-01

    T3i is an automated unit-testing tool to test Java classes. To expose interactions T3i generates test-cases in the form of sequences of calls to the methods of the target class. What separates it from other testing tools is that it treats test suites as first class objects and allows users to e.g.

  19. Benchmarking Post-Hartree–Fock Methods To Describe the Nonlinear Optical Properties of Polymethines: An Investigation of the Accuracy of Algebraic Diagrammatic Construction (ADC) Approaches

    KAUST Repository

    Knippenberg, Stefan

    2016-10-07

    Third-order nonlinear optical (NLO) properties of polymethine dyes have been widely studied for applications such as all-optical switching. However, the limited accuracy of the current computational methodologies has prevented a comprehensive understanding of the nature of the lowest excited states and their influence on the molecular optical and NLO properties. Here, attention is paid to the lowest excited-state energies and their energetic ratio, as these characteristics impact the figure-of-merit for all-optical switching. For a series of model polymethines, we compare several algebraic diagrammatic construction (ADC) schemes for the polarization propagator with approximate second-order coupled cluster (CC2) theory, the widely used INDO/MRDCI approach and the symmetry-adapted cluster configuration interaction (SAC-CI) algorithm incorporating singles and doubles linked excitation operators (SAC-CI SD-R). We focus in particular on the ground-to-excited state transition dipole moments and the corresponding state dipole moments, since these quantities are found to be of utmost importance for an effective description of the third-order polarizability γ and two-photon absorption spectra. A sum-overstates expression has been used, which is found to quickly converge. While ADC(3/2) has been found to be the most appropriate method to calculate these properties, CC2 performs poorly.

  20. Performance demonstration tests for eddy current inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given