WorldWideScience

Sample records for acute whole-body proton

  1. Whole body proton irradiation causes acute damage to bone marrow hematopoietic progenitor and stem cells in mice.

    Science.gov (United States)

    Chang, Jianhui; Wang, Yingying; Pathak, Rupak; Sridharan, Vijayalakshmi; Jones, Tamako; Mao, Xiao Wen; Nelson, Gregory; Boerma, Marjan; Hauer-Jensen, Martin; Zhou, Daohong; Shao, Lijian

    2017-12-01

    Exposure to proton irradiation during missions in deep space can lead to bone marrow injury. The acute effects of proton irradiation on hematopoietic stem and progenitor cells remain undefined and thus were investigated. We exposed male C57BL/6 mice to 0.5 and 1.0 Gy proton total body irradiation (proton-TBI, 150 MeV) and examined changes in peripheral blood cells and bone marrow (BM) progenitors and LSK cells 2 weeks after exposure. 1.0 Gy proton-TBI significantly reduced the numbers of peripheral blood cells compared to 0.5 Gy proton-TBI and unirradiated animals, while the numbers of peripheral blood cell counts were comparable between 0.5 Gy proton-TBI and unirradiated mice. The frequencies and numbers of LSK cells and CMPs in BM of 0.5 and 1.0 Gy irradiated mice were decreased in comparison to those of normal controls. LSK cells and CMPs and their progeny exhibited a radiation-induced impairment in clonogenic function. Exposure to 1.0 Gy increased cellular apoptosis but not the production of reactive oxygen species (ROS) in CMPs two weeks after irradiation. LSK cells from irradiated mice exhibited an increase in ROS production and apoptosis. Exposure to proton-TBI can induce acute damage to BM progenitors and LSK cells.

  2. Gene Expression Changes in Mouse Intestinal Tissue Following Whole-Body Proton or Gamma-Irradiation

    Science.gov (United States)

    Purgason, Ashley; Zhang, Ye; Mangala, Lingegowda; Nie, Ying; Gridley, Daila; Hamilton, Stanley R.; Seidel, Derek V.; Wu, Honglu

    2014-01-01

    Crew members face potential consequences following exposure to the space radiation environment including acute radiation syndrome and cancer. The space radiation environment is ample with protons, and numerous studies have been devoted to the understanding of the health consequences of proton exposures. In this project, C57BL/6 mice underwent whole-body exposure to 250 MeV of protons at doses of 0, 0.1, 0.5, 2 and 6 Gy and the gastrointestinal (GI) tract of each animal was dissected four hours post-irradiation. Standard H&E staining methods to screen for morphologic changes in the tissue showed an increase in apoptotic lesions for even the lowest dose of 0.1 Gy, and the percentage of apoptotic cells increased with increasing dose. Results of gene expression changes showed consistent up- or down- regulation, up to 10 fold, of a number of genes across exposure doses that may play a role in proton-induced oxidative stress including Gpx2. A separate study in C57BL/6 mice using the same four hour time point but whole-body gamma-irradiation showed damage to the small intestine with lesions appearing at the smallest dose of 0.05 Gy and increasing with increasing absorbed dose. Expressions of genes associated with oxidative stress processes were analyzed at four hours and twenty-four hours after exposure to gamma rays. We saw a much greater number of genes with significant up- or down-regulation twenty-four hours post-exposure as compared to the four hour time point. At both four hours and twenty-four hours post-exposure, Duox1 and Mpo underwent up-regulation for the highest dose of 6 Gy. Both protons and gamma rays lead to significant variation in gene expressions and these changes may provide insight into the mechanism of injury seen in the GI tract following radiation exposure. We have also completed experiments using a BALB/c mouse model undergoing whole-body exposure to protons. Doses of 0, 0.1, 1 and 2 Gy were used and results will be compared to the work mentioned

  3. Acute volume expansion preserves orthostatic tolerance during whole-body heat stress in humans.

    Science.gov (United States)

    Keller, David M; Low, David A; Wingo, Jonathan E; Brothers, R Matthew; Hastings, Jeff; Davis, Scott L; Crandall, Craig G

    2009-03-01

    Whole-body heat stress reduces orthostatic tolerance via a yet to be identified mechanism(s). The reduction in central blood volume that accompanies heat stress may contribute to this phenomenon. The purpose of this study was to test the hypothesis that acute volume expansion prior to the application of an orthostatic challenge attenuates heat stress-induced reductions in orthostatic tolerance. In seven normotensive subjects (age, 40 +/- 10 years: mean +/- S.D.), orthostatic tolerance was assessed using graded lower-body negative pressure (LBNP) until the onset of symptoms associated with ensuing syncope. Orthostatic tolerance (expressed in cumulative stress index units, CSI) was determined on each of 3 days, with each day having a unique experimental condition: normothermia, whole-body heating, and whole-body heating + acute volume expansion. For the whole-body heating + acute volume expansion experimental day, dextran 40 was rapidly infused prior to LBNP sufficient to return central venous pressure to pre-heat stress values. Whole-body heat stress alone reduced orthostatic tolerance by approximately 80% compared to normothermia (938 +/- 152 versus 182 +/- 57 CSI; mean +/- S.E.M., P body heating completely ameliorated the heat stress-induced reduction in orthostatic tolerance (1110 +/- 69 CSI, P stress results in many cardiovascular and neural responses that directionally challenge blood pressure regulation, reduced central blood volume appears to be an underlying mechanism responsible for impaired orthostatic tolerance in the heat-stressed human.

  4. Whole spine MRI in the assessment of acute vertebral body trauma

    International Nuclear Information System (INIS)

    Green, R.A.R.; Saifuddin, A.

    2004-01-01

    To determine the incidence and types of multilevel vertebral body injury in association with acute spinal trauma as assessed by whole spine MRI. All acute admissions to a regional spinal injury unit had whole spine MRI carried out, to detect occult vertebral body injury. Two radiologists assessed 127 cases prospectively, over a period of 3 years. All cases had T2-weighted sagittal imaging of the whole spine (where possible using a T2-weighted fat-suppressed sequence), with T1-weighted imaging in both sagittal and axial planes covering the primary injury. The incidence of secondary injury (defined as either bone bruising, wedge compression fracture or burst fracture) was determined and defined by type, site and relationship to the primary injury. Seventy-seven per cent of cases had a secondary injury level. Of these, bone bruising was the commonest but often occurred in combination with secondary wedge compression fracture or burst fracture. MRI detected 27 non-contiguous wedge compression fractures and 16 non-contiguous burst fractures, giving an incidence of secondary level, non-contiguous fracture of approximately 34%. A higher frequency of secondary vertebral body injury may be defined by MRI than has been described in previous studies based on radiographic evaluation of the whole spine. Whole spine MRI in assessment for occult vertebral body fracture enables increased confidence in the conservative or surgical management of patients with severe spinal injury. (orig.)

  5. Acute interleukin-6 administration does not impair muscle glucose uptake or whole-body glucose disposal in healthy humans

    DEFF Research Database (Denmark)

    Steensberg, Adam; Fischer, Christian P; Sacchetti, Massimo

    2003-01-01

    adrenaline (epinephrine). IL-6 infusion, irrespective of dose, did not result in any changes to endogenous glucose production, whole-body glucose disposal or leg- glucose uptake. These data demonstrate that acute IL-6 administration does not impair whole-body glucose disposal, net leg-glucose uptake......The cytokine interleukin (IL)-6 has recently been linked with type 2 diabetes mellitus and has been suggested to affect glucose metabolism. To determine whether acute IL-6 administration affects whole-body glucose kinetics or muscle glucose uptake, 18 healthy young men were assigned to one of three...... the cessation of infusion (recovery) to determine endogenous glucose production and whole-body glucose disposal. Infusion with HiIL-6 and LoIL-6 resulted in a marked (P

  6. A Comparison of Molecular and Histopathological Changes in Mouse Intestinal Tissue Following Whole-Body Proton- or Gamma-Irradiation

    Science.gov (United States)

    Purgason, Ashley; Mangala, Lingegowda; Zhang, Ye; Hamilton, Stanley; Wu, Honglu

    2010-01-01

    There are many consequences following exposure to the space radiation environment which can adversely affect the health of a crew member. Acute radiation syndrome (ARS) involving nausea and vomiting, damage to radio-sensitive tissue such as the blood forming organs and gastrointestinal tract, and cancer are some of these negative effects. The space radiation environment is ample with protons and contains gamma rays as well. Little knowledge exists to this point, however, regarding the effects of protons on mammalian systems; conversely several studies have been performed observing the effects of gamma rays on different animal models. For the research presented here, we wish to compare our previous work looking at whole-body exposure to protons using a mouse model to our studies of mice experiencing whole-body exposure to gamma rays as part of the radio-adaptive response. Radio-adaptation is a well-documented phenomenon in which cells exposed to a priming low dose of radiation prior to a higher dose display a reduction in endpoints like chromosomal aberrations, cell death, micronucleus formation, and more when compared to their counterparts receiving high dose-irradiation only. Our group has recently completed a radio-adaptive experiment with C57BL/6 mice. For both this study and the preceding proton research, the gastrointestinal tract of each animal was dissected four hours post-irradiation and the isolated small intestinal tissue was fixed in formalin for histopathological examination or snap-frozen in liquid nitrogen for RNA isolation. Histopathologic observation of the tissue using standard H&E staining methods to screen for morphologic changes showed an increase in apoptotic lesions for even the lowest doses of 0.1 Gy of protons and 0.05 Gy of gamma rays, and the percentage of apoptotic cells increased with increasing dose. A smaller percentage of crypts showed 3 or more apoptotic lesions in animals that received 6 Gy of gamma-irradiation compared to mice

  7. Acute effects of whole body gamma irradiation on exocrine pancreatic secretion in the pig

    International Nuclear Information System (INIS)

    Monti, P.; Scanff, P.; Joubert, C.; Vergnet, M.; Grison, S.; Griffiths, N.

    2004-01-01

    Reports on radiation damage to the pancreas deal essentially with long-term morphological changes with few data on pancreatic exocrine function. The aim of this work was to study the acute effects of whole body irradiation on volume and enzyme activities in the pancreatic juice. A whole body gamma irradiation (6 Gy) was investigated in pigs with continuous sampling of pancreatic juice before and after exposure via an indwelling catheter in the pancreatic duct. For each sample collected, total protein concentration and enzyme activities of trypsin, chymotrypsin, elastase, lipase and amylase were determined. Pancreatic juice volume was monitored during all periods of collection. The volume of pancreatic juice secreted daily decreased one day after irradiation and remained lower than the control values over the experimental period. Total proteins secreted in the pancreatic juice and total activities of pancreatic enzymes were reduced similarly. On the other hand, only specific activities of elastase and lipase were affected by irradiation. Whole body gamma irradiation resulted in a rapid and marked decrease of exocrine pancreatic secretion, in terms of volume as well as secreted enzymes. This may contribute in part to the intestinal manifestations of the acute and/or late radiation syndrome. (author)

  8. Acute effect of whole body vibration on postural control in congenitally blind subjects: a preliminary evidence.

    Science.gov (United States)

    di Cagno, Alessandra; Giombini, Arrigo; Iuliano, Enzo; Moffa, Stefano; Caliandro, Tiziana; Parisi, Attilio; Borrione, Paolo; Calcagno, Giuseppe; Fiorilli, Giovanni

    2017-07-11

    The purpose of this study was to investigate the acute effects of whole body vibration at optimal frequency, on postural control in blind subjects. Twenty-four participants, 12 congenital blind males (Experimental Group), and 12 non-disabled males with no visual impairment (Control Groups) were recruited. The area of the ellipse and the total distance of the center of pressure displacements, as postural control parameters, were evaluated at baseline (T0), immediately after the vibration (T1), after 10 min (T10) and after 20 min (T20). Whole body vibration protocol consisted into 5 sets of 1 min for each vibration, with 1 min rest between each set on a vibrating platform. The total distance of center of pressure showed a significant difference (p < 0.05) amongst groups, while the area remained constant. No significant differences were detected among times of assessments, or in the interaction group × time. No impairments in static balance were found after an acute bout of whole body vibration at optimal frequency in blind subjects and, consequently, whole body vibration may be considered as a safe application in individuals who are blind.

  9. Acute necrotizing encephalopathy secondary to diphtheria, tetanus toxoid and whole-cell pertussis vaccination: diffusion-weighted imaging and proton MR spectroscopy findings

    Energy Technology Data Exchange (ETDEWEB)

    Aydin, Hale; Ozgul, Esra; Agildere, Ahmet Muhtesem [Baskent University Hospital, Department of Radiology, Ankara (Turkey)

    2010-07-15

    We present a previously healthy 6-month-old boy who was admitted to our hospital with lethargy, hypotonia and focal clonic seizures 6 days following diptheria, tetanus toxoid and whole-cell pertussis vaccination. A diagnosis of acute necrotising encephalopathy was made with the aid of MRI, including diffusion-weighted imaging and proton MR spectroscopy. (orig.)

  10. Acute necrotizing encephalopathy secondary to diphtheria, tetanus toxoid and whole-cell pertussis vaccination: diffusion-weighted imaging and proton MR spectroscopy findings

    International Nuclear Information System (INIS)

    Aydin, Hale; Ozgul, Esra; Agildere, Ahmet Muhtesem

    2010-01-01

    We present a previously healthy 6-month-old boy who was admitted to our hospital with lethargy, hypotonia and focal clonic seizures 6 days following diptheria, tetanus toxoid and whole-cell pertussis vaccination. A diagnosis of acute necrotising encephalopathy was made with the aid of MRI, including diffusion-weighted imaging and proton MR spectroscopy. (orig.)

  11. Acute whole-body vibration increases reciprocal inhibition.

    Science.gov (United States)

    Ritzmann, Ramona; Krause, Anne; Freyler, Kathrin; Gollhofer, Albert

    2018-06-26

    Based on previous evidence that whole-body vibration (WBV) affects pathways involved in disynaptic reciprocal inhibition (DRI), the present hypothesis-driven experiment aimed to assess the acute effects of WBV on DRI and co-contraction. DRI from ankle dorsiflexors to plantar flexors was investigated during submaximal dorsiflexion before and after 1 min of WBV. With electromyography, musculus soleus (SOL) H-reflex depression following a conditioning stimulation of the peroneal nerve (1.1x motor threshold for the musculus tibialis anterior, TA) was assessed and co-contraction was calculated. After WBV, DRI was significantly increased (+4%, p < 0.05). SOL (-13%, p < 0.05) and TA (-6%, p < 0.05) activities were significantly reduced; co-contraction tended to be diminished (-8%, p = 0.05). Dorsiflexion torque remained unchanged. After WBV, DRI increased during submaximal isometric contraction in healthy subjects. The simultaneous SOL relaxation and TA contraction indicate that a more economic movement execution is of functional significance for WBV application in clinical and athletic treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Acute Whole Body Vibration Decreases the Glucose Levels in Elderly Diabetic Women

    Directory of Open Access Journals (Sweden)

    Maíra Florentino Pessoa

    2018-01-01

    Full Text Available Type II diabetes (TIIDM is characterized by high levels of blood glucose followed by excessive insulin release so that the target cells become less sensitive, developing insulin resistance and maintaining hyperglycemic levels. Physical activity is the strongest element to prevent and to manage the TIIDM, and the majority of patients do not remain in regularly active levels, because the premature fatigue in these patients decreases the adherence to the training. Contrastingly, the whole body vibration (WBV training may improve the glucose metabolism in diabetic patients, reducing the peripheral blood sugar, decreasing the physical discomfort and perceived exertion. Therefore, the purpose of the study was to determine the effect of an acute WBV session as therapy to promote fasting decreases in insulin levels in peripheral blood in TIIDM when compared to healthy elderly. For this, fifteen healthy elderly women and fourteen diabetic elderly women, all sedentary, were allocated in diabetic or control groups, and we made an acute whole body session composed of 10 bouts lasting 2 minutes each one, separated by a 30-second rest period. The WBV was executed in a triaxial platform MY3 Power Plate® at 35 hertz and has been chosen a peak-to-peak displacement of 4 millimeters. After the protocol, both groups decreased the glycemic levels and increased lactate production in relation to the basal levels and when compared diabetic and control, where the most important results have been shown in diabetic women. This study revealed that WBV training in TIIDM has had significant beneficial effects on the control of glucose levels, still in an acute session. So that, the complete training probably will show better results about glycemic control and this finding could be especially important when prescribing exercise for elderly who are unable or unwilling to use traditional loads or who show poor exercise compliance.

  13. The modes of death in mammals exposed to whole body radiation (acute radiation syndromes)

    International Nuclear Information System (INIS)

    Santos, O.R. dos.

    1990-07-01

    When an animal is exposed to a sufficient amount of radiation, there will be changes in many organs of the body, and as a result of either the effects in one particular organ or the interaction of effects in several organs, the animal as a whole will show characteristic syndromes. Some syndromes result inevitably in death. Others may or may not be lethal, depending on the extent of the tissue damage. The time of appearance of the syndromes, their duration, and the survival of the organism depend on many factors. Whole body acute doses of radiation produce the same spectrum of Central Nervous System (CNS), Gastrointestinal (GI) and Bone Marrow (BM) injury in man as was described for animals. Damage to the skin, ovary and testis are an integral and important part of the symptoms. (author) [pt

  14. Whole body perfusion in patients undergoing frozen elephant trunk for type A acute aortic dissections.

    Science.gov (United States)

    Cappabianca, Giangiuseppe; Roscitano, Claudio; Bichi, Samuele; Cricco, Antonio; Parrinello, Matteo; Beghi, Cesare; Albano, Giovanni; Esposito, Giampiero

    2017-03-01

    The Frozen Elephant Trunk (FET) can be adopted in selected type A acute aortic dissections (TAAAD). During FET, a prolonged distal circulatory arrest exposes the spine and visceral organs to potential ischemic injuries. Antegrade distal aortic perfusion (ADAP) could minimize this risk: we describe the technical aspects of the simultaneous use of antegrade cerebral perfusion (ACP) and ADAP achieving a "Whole Body Perfusion" (WBP) during FET.

  15. Acute whole-body cooling for exercise-induced hyperthermia: a systematic review.

    Science.gov (United States)

    McDermott, Brendon P; Casa, Douglas J; Ganio, Matthew S; Lopez, Rebecca M; Yeargin, Susan W; Armstrong, Lawrence E; Maresh, Carl M

    2009-01-01

    To assess existing original research addressing the efficiency of whole-body cooling modalities in the treatment of exertional hyperthermia. During April 2007, we searched MEDLINE, EMBASE, Scopus, SportDiscus, CINAHL, and Cochrane Reviews databases as well as ProQuest for theses and dissertations to identify research studies evaluating whole-body cooling treatments without limits. Key words were cooling, cryotherapy, water immersion, cold-water immersion, ice-water immersion, icing, fanning, bath, baths, cooling modality, heat illness, heat illnesses, exertional heatstroke, exertional heat stroke, heat exhaustion, hyperthermia, hyperthermic, hyperpyrexia, exercise, exertion, running, football, military, runners, marathoner, physical activity, marathoning, soccer, and tennis. Two independent reviewers graded each study on the Physiotherapy Evidence Database (PEDro) scale. Seven of 89 research articles met all inclusion criteria and a minimum score of 4 out of 10 on the PEDro scale. After an extensive and critical review of the available research on whole-body cooling for the treatment of exertional hyperthermia, we concluded that ice-water immersion provides the most efficient cooling. Further research comparing whole-body cooling modalities is needed to identify other acceptable means. When ice-water immersion is not possible, continual dousing with water combined with fanning the patient is an alternative method until more advanced cooling means can be used. Until future investigators identify other acceptable whole-body cooling modalities for exercise-induced hyperthermia, ice-water immersion and cold-water immersion are the methods proven to have the fastest cooling rates.

  16. Small and inconsistent effects of whole body vibration on athletic performance : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Hortobagyi, Tibor; Lesinski, Melanie; Fernandez-del-Olmo, Miguel; Granacher, Urs

    We quantified the acute and chronic effects of whole body vibration on athletic performance or its proxy measures in competitive and/or elite athletes. Systematic literature review and meta-analysis. Whole body vibration combined with exercise had an overall 0.3 % acute effect on maximal voluntary

  17. Professional Soccer Player Neuromuscular Responses and Perceptions to Acute Whole Body Vibration Differ from Amateur Counterparts

    Directory of Open Access Journals (Sweden)

    Ross Cloak, Andrew Lane, Matthew Wyon

    2016-03-01

    Full Text Available Acute whole body vibration (WBV is an increasingly popular training technique amongst athletes immediately prior to performance and during scheduled breaks in play. Despite its growing popularity, evidence to demonstrate its effectiveness on acute neuromuscular responses is unclear, and suggestions that athlete ability impacts effectiveness warrant further investigation. The purpose of this study was to compare the neuromuscular effects of acute WBV and perceptions of whether WBV is an effective intervention between amateur and professional soccer players. Participants were 44 male soccer players (22 professional and 22 amateur; age: 23.1 ± 3.7 years, body mass: 75.6 ± 8.8 kg and height: 1.77 ± 0.05 m. Participants in each group were randomly assigned to either an intervention of 3 x 60 s of WBV at 40 Hz (8mm peak-to-peak displacement or control group. Peak knee isometric force, muscle activation and post activation potentiation (PAP of the knee extensors along with self-report questionnaire of the perceived benefits of using the intervention were collected. A three-way ANOVA with repeated measures revealed professional players demonstrated a significant 10.6% increase (p < 0.01, Partial Eta2 = 0.22 in peak knee isometric force following acute WBV with no significant differences among amateur players. A significant difference (p < 0.01, Partial Eta2 = 0.16 in PAP amongst professional players following acute WBVT was also reported. No significant differences amongst amateur players were reported across measurements. Results also indicated professional players reported significantly stronger positive beliefs in the effectiveness of the WBV intervention (p < 0.01, Partial Eta2 = 0.27 compared to amateur players. Acute WBV elicited a positive neuromuscular response amongst professional players identified by PAP and improvements in knee isometric peak force as well as perceived benefits of the intervention, benefits not found among amateur players.

  18. Whole Body Vibration Improves Cognition in Healthy Young Adults

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Van Heuvelen, Marieke J. G.; Zeinstra, Edzard B.; Fuermaier, Anselm B.M.; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van der Zee, Eddy A.

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5 +/- 2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration

  19. Acute and Chronic Whole-Body Vibration Exercise does not Induce Health-Promoting Effects on The Blood Profile

    Directory of Open Access Journals (Sweden)

    Theodorou Anastasios A.

    2015-06-01

    Full Text Available Whole-body vibration (WBV exercise is an alternative, popular and easy exercise that can be followed by general public. Therefore, the aim of the present study was to investigate the influence of acute and chronic WBV exercise on health-related parameters. Twenty-eight women were allocated into a control group (n=11, mean ±SEM: age, 43.5 ±1.5 yr; body mass, 66.1 ±3.1 kg; height, 160.6 ±1.5 cm and a vibration group (n=17, mean ±SEM: age, 44.0 ±1.0 yr; body mass, 67.1 ±2.2 kg; height, 162.5 ±1.5 cm. After baseline assessments, participants of the experimental group performed WBV training 3 times/week for 8 weeks. Before and after the chronic WBV exercise, the participants of the vibration group performed one session of acute WBV exercise. Blood chemistry measurements (hematology, creatine kinase, lactate dehydrogenase, aspartate aminotransferase, alanine aminotransferase, C-reactive protein, glucose, insulin, triacylglycerols, total cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, apolipoprotein A1, apolipoprotein B and lipoprotein, thiobarbituric-acid reactive substances, protein carbonyls, total antioxidant capacity, uric acid, albumin and bilirubin were assessed pre-exercise and post-exercise at the first and eighth week of WBV exercise in both control and vibration groups. The results failed to support any effect of both acute and chronic WBV exercise on biochemical health-related parameters. However, it seems that WBV exercise is a safe way of training without a negative impact on muscle and liver functionality.

  20. Radiobiologic considerations about further development of whole-body irradiation with subsequent bone marrow transplantation applied during the treatment of acute leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Trott, K R; Holler, E; Kolb, H J

    1981-08-01

    The results achieved hitherto with whole-body irradiation in case of acute leukemia are examined with respect to the optimization criteria of a radiotherapy. The most important failure risk is the recurrence which occurs in more than 50% of all cases, then follows the interstitial pneumonia. The authors think that an increase of the total dose, the adaption of the dose distribution to the distribution of leukemia cells in the body, and a higher fractionation of the total dose are approaches for improving the therapy results.

  1. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  2. Acute effects of unilateral whole body vibration training on single leg vertical jump height and symmetry in healthy men.

    Science.gov (United States)

    Shin, Seungho; Lee, Kyeongjin; Song, Changho

    2015-12-01

    [Purpose] The aim of the present study was to investigate the acute effects of unilateral whole body vibration training on height and symmetry of the single leg vertical jump in healthy men. [Subjects] Thirty males with no history of lower limb dysfunction participated in this study. [Methods] The participants were randomly allocated to one of three groups: the unilateral vibratory stimulation group (n=10), bilateral vibratory stimulation group (n=10), and, no vibratory stimulation group (n=10). The subjects in the unilateral and bilateral stimulation groups participated in one session of whole body vibration training at 26 Hz for 3 min. The no vibratory stimulation group subjects underwent the same training for 3 min without whole body vibration. All participants performed the single leg vertical jump for each lower limb, to account for the strong and weak sides. The single leg vertical jump height and symmetry were measured before and after the intervention. [Results] The single leg vertical jump height of the weak lower limb significantly improved in the unilateral vibratory stimulation group, but not in the other groups. The single leg vertical jump height of the strong lower limb significantly improved in the bilateral vibratory stimulation group, but not in the other groups. The single leg vertical jump symmetry significantly improved in the unilateral vibratory stimulation group, but not in the other groups. [Conclusion] Therefore, the present study found that the effects of whole body vibration training were different depending on the type of application. To improve the single leg vertical jump height in the weak lower limbs as well as limb symmetry, unilateral vibratory stimulation might be more desirable.

  3. Proton Therapy for Spinal Ependymomas: Planning, Acute Toxicities, and Preliminary Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Amsbaugh, Mark J. [Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Grosshans, David R., E-mail: dgrossha@mdanderson.org [Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); McAleer, Mary Frances; Zhu, Ron; Wages, Cody; Crawford, Cody N.; Palmer, Matthew; De Gracia, Beth; Woo Shiao; Mahajan, Anita [Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2012-08-01

    Purpose: To report acute toxicities and preliminary outcomes for pediatric patients with ependymomas of the spine treated with proton beam therapy at the MD Anderson Cancer Center. Methods and Materials: Eight pediatric patients received proton beam irradiation between October 2006 and September 2010 for spinal ependymomas. Toxicity data were collected weekly during radiation therapy and all follow-up visits. Toxicities were graded according to the Common Terminology Criteria for Adverse Events version 3.0. Results: All patients had surgical resection of the tumor before irradiation (7 subtotal resection and 1 gross total resection). Six patients had World Health Organization Grade I ependymomas, and two had World Health Organization Grade II ependymomas. Patients had up to 3 surgical interventions before radiation therapy (range, 1-3; median, 1). Three patients received proton therapy after recurrence and five as part of their primary management. The entire vertebral body was treated in all but 2 patients. The mean radiation dose was 51.1 cobalt gray equivalents (range, 45 to 54 cobalt gray equivalents). With a mean follow-up of 26 months from the radiation therapy start date (range, 7-51 months), local control, event-free survival, and overall survival rates were all 100%. The most common toxicities during treatment were Grade 1 or 2 erythema (75%) and Grade 1 fatigue (38%). No patients had a Grade 3 or higher adverse event. Proton therapy dramatically reduced dose to all normal tissues anterior to the vertebral bodies in comparison to photon therapy. Conclusion: Preliminary outcomes show the expected control rates with favorable acute toxicity profiles. Proton beam therapy offers a powerful treatment option in the pediatric population, where adverse events related to radiation exposure are of concern. Extended follow-up will be required to assess for late recurrences and long-term adverse effects.

  4. Whole-body irradiation transiently diminishes the adrenocorticotropin response to recombinant human interleukin-1{alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Perlstein, R.S.; Mehta, N.R.; Neta, R.; Whitnall, M.H. [Armed Forces Radiobiology Research Institute, Bethesda, MD (United States); Mougey, E.H. [Walter Reed Army Institute of Research, Washington, DC (United States)

    1995-03-01

    Recombinant human interleukin-1{alpha} (rhIL-1{alpha}) has significant potential as a radioprotector and/or treatment for radiation-induced hematopoietic injury. Both IL-1 and whole-body ionizing irradiation acutely stimulate the hypothalamic-pituitary-adrenal axis. We therefore assessed the interaction of whole-body irradiation and rhIL-1{alpha} in altering the functioning of the axis in mice. Specifically, we determined the adrenocorticotropin (ACTH) and corticosterone responses to rhIL-1{alpha} administered just before and hours to days after whole-body or sham irradiation. Our results indicate that whole-body irradiation does not potentiate the rhIL-1{alpha}-induced increase in ACTH levels at the doses used. In fact, the rhIL-1{alpha}-induced increase in plasma ACTH is transiently impaired when the cytokine is administered 5 h after, but not 1 h before, exposure to whole-body irradiation. The ACTH response may be inhibited by elevated corticosterone levels after whole-body irradiation, or by other radiation-induced effects on the pituitary gland and hypothalamus. 36 refs., 3 figs.

  5. Late biochemical changes in the rat lung after whole body irradiation

    International Nuclear Information System (INIS)

    Dancewicz, A.M.; Kubicka, T.

    1976-01-01

    Young Wistar rats were exposed to 650 R of whole body X-rays then sacrificed at different times after exposure up to one year, and various biochemical parameters in lung tissue were determined. Decrease in protein and elastin content and elevation in fibrinolytic and catheptic activity lasted during the whole observation period. In other parameters a fluctuation, mostly decrease followed by an increase, was seen only during the acute phase of radiation disease. (author)

  6. Whole-body MRI screening

    Energy Technology Data Exchange (ETDEWEB)

    Puls, Ralf [HELIOS Klinikum Erfurt (Germany). Inst. of Diagnostic and Interventional Radiology and Neuroradiology; Hosten, Norbert (ed.) [Universitaetsklinikum Greifswald (Germany). Diagnostic Radiology and Neuroradiology

    2014-07-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  7. Whole-body MRI screening

    International Nuclear Information System (INIS)

    Puls, Ralf; Hosten, Norbert

    2014-01-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  8. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  9. Acute Whole-Body Vibration does not Facilitate Peak Torque and Stretch Reflex in Healthy Adults

    Directory of Open Access Journals (Sweden)

    Ella W. Yeung

    2013-03-01

    Full Text Available The acute effect of whole-body vibration (WBV training may enhance muscular performance via neural potentiation of the stretch reflex. The purpose of this study was to investigate if acute WBV exposure affects the stretch induced knee jerk reflex [onset latency and electromechanical delay (EMD] and the isokinetic knee extensor peak torque performance. Twenty-two subjects were randomly assigned to the intervention or control group. The intervention group received WBV in a semi-squat position at 30° knee flexion with an amplitude of 0.69 mm, frequency of 45 Hz, and peak acceleration of 27.6 m/s2 for 3 minutes. The control group underwent the same semii-squatting position statically without exposure of WBV. Two-way mixed repeated measures analysis of variance revealed no significant group effects differences on reflex latency of rectus femoris (RF and vastus lateralis (VL; p = 0.934 and 0.935, respectively EMD of RF and VL (p = 0.474 and 0.551, respectively and peak torque production (p = 0.483 measured before and after the WBV. The results of this study indicate that a single session of WBV exposure has no potentiation effect on the stretch induced reflex and peak torque performance in healthy young adults.

  10. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  11. Acute skin reactions observed in fractionated proton irradiation

    International Nuclear Information System (INIS)

    Arimoto, Takuro; Maruhashi, Noboru; Takada, Yoshihisa; Hayakawa, Yoshinori; Inada, Tetsuo; Kitagawa, Toshio

    1989-01-01

    Between May 1985 and July 1987, 49 skin reactions of 43 patients treated by proton irradiation were observed at the Particle Radiation Medical Science Center (PARMS), the University of Tsukuba. Taking the peak skin score as an endpoint, the radiobiological effects [relative biological effectiveness (RBE) and time-dose relationship] of the proton beam in multi-fractionated treatments were estimated. Factors influencing the skin dose, such as the prescribed tumor dose, tumor site, and number of applied fields, were also analyzed. The following conclusions regarding acute skin reactions to the clinical use of proton irradiation were obtained: 1) the physical skin-sparing effect of proton irradiation in single-field irradiation, especially in superficial regions, is not large compared with that of high-energy photon irradiation; 2) multidirectional proton irradiation significantly reduced the skin dose and severity of acute reasons; 3) the radiobiological effects of the proton beam, RBE and the time factor, estimated in human skin in multi-fractional treatment were slightly smaller than those of X-rays, i.e., 0.92 and -0.25±0.09, respectively. (author)

  12. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  13. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  14. Acute effects of whole-body vibration on the motor function of patients with stroke: a randomized clinical trial.

    Science.gov (United States)

    Silva, Adriana Teresa; Dias, Miqueline Pivoto Faria; Calixto, Ruanito; Carone, Antonio Luis; Martinez, Beatriz Bertolaccini; Silva, Andreia Maria; Honorato, Donizeti Cesar

    2014-04-01

    The aim of this study was to investigate the acute effects of whole-body vibration on the motor function of patients with stroke. The present investigation was a randomized clinical trial studying 43 individuals with hemiparesis after stroke, with 33 subjects allocated to the intervention group and 10 subjects allocated to the control group. The intervention group was subjected to one session of vibration therapy (frequency of 50 Hz and amplitude of 2 mm) comprising four 1-min series with 1-min rest intervals between series in three body positions: bipedal stances with the knees flexed to 30 degrees and 90 degrees and a unipedal stance on the paretic limb. The analytical tests were as follows: simultaneous electromyography of the affected and unaffected tibialis anterior and rectus femoris muscles bilaterally in voluntary isometric contraction; the Six-Minute Walk Test; the Stair-Climb Test; and the Timed Get-Up-and-Go Test. The data were analyzed by independent and paired t tests and by analysis of covariance. There was no evidence of effects on the group and time interaction relative to variables affected side rectus femoris, unaffected side rectus femoris, affected side tibialis anterior, unaffected side tibialis anterior, and the Stair-Climb Test (P > 0.05). There was evidence of effects on the group interaction relative to variables Six-Minute Walk Test and Timed Get-Up-and-Go Test (P < 0.05). Whole-body vibration contributed little to improve the functional levels of stroke patients.

  15. Whole Body Vibration Improves Cognition in Healthy Young Adults

    OpenAIRE

    Regterschot, G. Ruben H.; Van Heuvelen, Marieke J. G.; Zeinstra, Edzard B.; Fuermaier, Anselm B. M.; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van Der Zee, Eddy A.

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5 +/- 2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on ...

  16. The evolution of whole-body imaging.

    LENUS (Irish Health Repository)

    Moran, Deirdre E

    2012-02-01

    This article reviews the evolution of whole-body imaging, discussing the history and development of radiography, nuclear medicine, computed tomography (CT), positron emission tomography (PET), combined PET-CT, and magnetic resonance imaging. The obstacles hindering progress toward whole-body imaging using each of these modalities, and the technical advances that were developed to overcome them, are reviewed. The effectiveness and the limitations of whole-body imaging with each of these techniques are also briefly discussed.

  17. Whole body monitoring - Goiania

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Bertelli Neto, L.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: - Individual from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1). - Occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121,57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was established according to the Cs activity present in the body or to the job to be assigned. In this paper we will present some burden activity curves for Cs 137 as a function of the time elapsed from the first measurement. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity x time curve. (author) [pt

  18. Early diagnosis and monitoring of whole-body accidental exposure

    International Nuclear Information System (INIS)

    Flury-Herard, A.; Jullien, D.

    1987-01-01

    This paper deals with the handling of accidental, acute or protracted, whole-body overexposures. It is complementary to the report DPS 86/07 SEAPS previously published. The criteria for initial classification, as a function of the mean absorbed dose, the clinical and paraclinical evaluation, the monitoring methods and the treatments to undertake are described successively. The basic components of the therapy are the intensive care of the hematological syndrome with blood products transfusions and anti-infection prophylaxy. The indications and conditions for bone-marrow grafts are also discussed [fr

  19. Whole-body counters in Canada

    International Nuclear Information System (INIS)

    Letourneau, C.

    1986-08-01

    A compilation of whole-body counting existing across Canada was prepared by AECB (Atomic Energy Control Board) staff. This work was initiated so that AECB staff and other concerned parties would have this information readily available, especially during urgent situations. This report is to be used for reference purposes only, as it makes no attempt to judge the present state of the art of whole-body counting

  20. Comparison of the effects of whole-body cooling during fatiguing exercise in males and females.

    Science.gov (United States)

    Solianik, Rima; Skurvydas, Albertas; Pukėnas, Kazimieras; Brazaitis, Marius

    2015-08-01

    The effects of cold stress on exercise performance and fatigue have been thoroughly investigated only in males, and thus the general understanding of these effects relates only to males. The aim of this study was to determine whether whole-body cooling has different effects on performance during fatiguing exercise in males and females. Thirty-two subjects (18 males and 14 females) were exposed to acute cold stress by intermittent immersion in 14°C water until their rectal temperature reached 35.5°C or for a maximum of 170 min. Thermal responses and motor performance were monitored before and after whole-body cooling. Whole-body cooling decreased rectal, muscle and mean skin temperatures in all subjects (pCold stress decreased the fatigue index (FI) of a sustained 2-min maximal voluntary contraction (MVC) only in males (pbody cooling-induced decrease in the FI of a sustained MVC in males but not in females) supports the view of sex effects on performance during fatiguing exercise after whole-body cooling. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Comparison of whole-body-imaging methods

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hoffer, P.

    1977-01-01

    Currently there are four different devices that have found clinical utility in whole-body imaging. These are the rectilinear scanner, the multicrystal whole-body scanner, the Anger-type camera with a whole-body-imaging table, and the tomoscanner. In this text, the basic theory of operation and a discussion of the advantages and disadvantages in whole-body imaging is presented for each device. When applicable, a comparative assessment of the various devices is also presented. As with all else in life, there is no simple answer to the question ''which total body imaging device is best.'' Institutions with a very heavy total-body-imaging load may prefer to use an already available dual-headed rectilinear scanner system for these studies, rather than invest in a new instrument. Institutions with moderate total-body-imaging loads may wish to invest in moving table or moving camera devices which make total body imaging more convenient but retain the basic flexibility of the camera. The large-field Anger camera with or without motion offers another flexible option to these institutions. The laboratory with a very heavy total body imaging load may select efficiency over flexibility, thereby freeing up other instruments for additional studies. Finally, reliability as well as availability and quality of local service must be considered. After all, design features of an instrument become irrelevant when it is broken down and awaiting repair

  2. Transformation of myelodysplastic syndrome to acute myeloid leukemia: a case with whole-body 2- (18F) fluoro-2-deoxy-D-glucose positron emission tomography

    International Nuclear Information System (INIS)

    Liu, Fang; Cao, Qinghua

    2011-01-01

    The case reported here was that of an old woman characterized by pancytopenia, chromosome clonal abnormality, fluctuation of the percent of blast cells at 20%, and negative evidence of malignancy in whole-body 2-( 18 F) fluoro-2-deoxy-D-glucose positron emission tomography ( 18 F-FDG PET). After about 10 months, the blast cells accounted for about 25%, the morphology of which was similar to that of previous ones, and 18 F-FDG PET demonstrated diffusing increased uptake in the right upper leg and lymph nodes and patchy high uptake of bone marrow. 2-( 18 F)-fluoro-2-deoxyglucose can reflect extramedullary infiltration and bone marrow cellularity of the whole body, compared with invasive, regional biopsies and aspirations. The value of 2-( 18 F)-fluoro-2-deoxyglucose or 3'-deoxy-3'-( 18 F)-fluorothymidine positron emission tomography as an indicator in predicting the transformation of myelodysplastic syndrome to acute myeloid leukemia needs to be explored in the future. (author)

  3. Acoustical method of whole-body hydration status monitoring

    Science.gov (United States)

    Sarvazyan, A. P.; Tsyuryupa, S. N.; Calhoun, M.; Utter, A.

    2016-07-01

    An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscle is a linear function of water content and can be referenced to the hydration status of the body. Studies on the validity of HM for the assessment of whole-body hydration status were conducted in the Appalachian State University, USA, on healthy young adults and on elderly subjects residing at an assisted living facility. The HM was able to track changes in total body water during periods of acute dehydration and rehydration in athletes and day-to-day and diurnal variability of hydration in elderly. Results of human studies indicate that HM has a potential to become an efficient tool for detecting abnormal changes in the body hydration status.

  4. Measurement of whole body cellular and collagen nitrogen, potassium, and other elements by neutron activation and whole body counting

    International Nuclear Information System (INIS)

    James, H.M.; Fabricius, P.J.; Dykes, P.W.

    1987-01-01

    Whole body nitrogen can be measured by neutron activation analysis with an acceptable radiation dose; it is an index of body protein which, in normal subjects, is 65% cellular protein and 35% extracellular connective collagen. Whole body potassium can be measured by whole body counting without irradiating the subject; it is an index of body cell mass. We measured whole body nitrogen, potassium, extracellular water, intracellular water, and fat-folds. The differences between 37 malnourished patients and five normal subjects suggested that the patients had 9 kg less cell mass than normal, but no difference in extracellular mass. Measurements were made on eight patients before and after 14 days of total parenteral nutrition; balance of nitrogen intake and excretion also was measured. The changes were consistent with mean increases of 3 kg of cellular mass and 3 kg of fat with no change of extracellular mass. The accuracy and sensitivity of the whole body measurements need further confirmation for use in patients with changing body composition. Where tissue wasting is largely from the cellular compartment, potassium could be a more sensitive index of wasting than nitrogen. Multielement analysis of nitrogen, potassium, chlorine, and carbon will probably be valuable in elucidating body composition in malnutrition

  5. Acid-base status after whole-body irradiation in dairy cows

    International Nuclear Information System (INIS)

    Schaefer, M.; Koch, F.; Dyrba, W.; Kirbach, M.

    1989-01-01

    Whole-body irradiation using 9 MeV X-rays of a linear accelerator of 10 clinically healthy lactating cows aged between 3.5 and 8 years produced an acute radiation syndrome in the LD 100/30 range. Blood analysis 1 day after irradiation showed a compensated metabolic acidosis with a low renal net acid-base excretion and hyerphosphaturia. Later the acid-base status indicated a differently marked metabolic alkalosis. In the main reaction period acidotic disturbances occurred, which partially were camouflaged by respiratory alkalosis. (author)

  6. 3D whole body scanners revisited

    NARCIS (Netherlands)

    Daanen, H.A.M.; Haar, F.B. ter

    2013-01-01

    An overview of whole body scanners in 1998 (H.A.M. Daanen, G.J. Van De Water. Whole body scanners, Displays 19 (1998) 111-120) shortly after they emerged to the market revealed that the systems were bulky, slow, expensive and low in resolution. This update shows that new developments in sensing and

  7. Ultrastructural changes in spermatogonia of Wistar strain rats following acute whole-body X-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hrehorovsky, M; Horak, J [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes in spermatogonia ultrastructure in rats of Wistar strain after single whole-body X-ray irradiation with 6.4 mC.kg/sup -1/, 25.8 mC.kg/sup -1/ and 51.6 mC.kg/sup -1/ respectively, were studied. Intracellular spaces were found between spermatogonia enlarged, nuclear membranes were bent, the pheripheral teritories of chromation were electronoptically denser, the morphology of nucleoli was changed, cytoplasm was vacuolised, mitochondria were damaged, the vacuolar dilatation of agranular endoplasmic reticulum was evident and electronoptically empty vacuoles near the Golgi complex occured 48 hours after single whole-body X-ray irradiation. Qualitative changes in the ultrastructure of individual types of spermatogonia after individual exposures were similar.

  8. RBE of heavy ions (carbon, neon, helium, proton) for acute cell death of pancreatic islet cells

    International Nuclear Information System (INIS)

    Tsubouchi, Susumu; Fukutsu, Kumiko; Itsukaichi, Hiromi

    2003-01-01

    At this fiscal year, only two times irradiation experiments with neon and helium beams were performed to obtain relative biological effectiveness (RBE) of heavy ions (carbon, neon, helium, proton) for acute cell death of pancreatic islet cells in vivo. First of all this project was designed to obtain RBE of 290 MeV carbon and 400 MeV neon beams in the high linear energy transfer (LET) region for acute cell death of pancreatic islets of golden hamster (Mesocricetus auratus) in the condition of in both in vivo and in vitro systems. As mentioned in previous report, in vitro system, however, resulted in ill success. This in vitro experiment was tentatively shelved for the time being. In return in vivo experiments for low LET region of neon beams (32.5 KeV/u), carbon beams (15.0 KeV/u) and helium beams (2 KeV/u) were performed in these two years. Last year these results together with those previously obtained for 200 KeV X-ray, 70 MeV proton, 290 MeV carbon (60 KeV/u), and neon (100 KeV/u) beams were reconsidered. At this year dose response relations (25, 50, 100, 150, and 200 Gy respectively) in acute cell death of pancreatic islets studied histologically after whole body irradiation of 3 weeks young male golden hamster with lower LET helium beams (2 KeV/u) and neon beams (32.5 KeV/u). Results indicated that mean cell lethal dose (Do) of helium beams (2 KeV/u) and neon beams (32.5 KeV/u) were 38 Gy and 49 Gy, respectively. Previously obtained Do data for 200 KeV x-ray, 70 MeV proton, 290 MeV carbon (15 KeV/u), 400 MeV neon (32.5 KeV/u), 290 MeV carbon (60 KeV/u), and 400 MeV neon (100 KeV/u) beams were 37 Gy, 38 Gy, 38 Gy, 49 Gy, 75 Gy, and 200 Gy, respectively. From these data estimated RBE of neon (100 KeV/u and 32.5 KeV/u), carbon (60 KeV/u and 15.0 KeV/u), 70 MeV proton and 150 MeV helium (2 KeV/u) beams were 0.19, 0.76, 0.49, 0.97, 0.97, 0.97, respectively. Therefore the order of RBE (or radiosensitivities) of islets cells with these various heavy ion beams was

  9. Quantification of interstitial fluid on whole body CT: comparison with whole body autopsy.

    Science.gov (United States)

    Lo Gullo, Roberto; Mishra, Shelly; Lira, Diego A; Padole, Atul; Otrakji, Alexi; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Singh, Sarabjeet; Shepard, Jo-Anne O; Digumarthy, Subba R; Kalra, Mannudeep K; Stone, James R

    2015-12-01

    Interstitial fluid accumulation can occur in pleural, pericardial, and peritoneal spaces, and subcutaneous tissue planes. The purpose of the study was to assess if whole body CT examination in a postmortem setting could help determine the presence and severity of third space fluid accumulation in the body. Our study included 41 human cadavers (mean age 61 years, 25 males and 16 females) who had whole-body postmortem CT prior to autopsy. All bodies were maintained in the morgue in the time interval between death and autopsy. Two radiologists reviewed the whole-body CT examinations independently to grade third space fluid in the pleura, pericardium, peritoneum, and subcutaneous space using a 5-point grading system. Qualitative CT grading for third space fluid was correlated with the amount of fluid found on autopsy and the quantitative CT fluid volume, estimated using a dedicated software program (Volume, Syngo Explorer, Siemens Healthcare). Moderate and severe peripheral edema was seen in 16/41 and 7/41 cadavers respectively. It is not possible to quantify anasarca at autopsy. Correlation between imaging data for third space fluid and the quantity of fluid found during autopsy was 0.83 for pleural effusion, 0.4 for pericardial effusion and 0.9 for ascites. The degree of anasarca was significantly correlated with the severity of ascites (p < 0.0001) but not with pleural or pericardial effusion. There was strong correlation between volumetric estimation and qualitative grading for anasarca (p < 0.0001) and pleural effusion (p < 0.0001). Postmortem CT can help in accurate detection and quantification of third space fluid accumulation. The quantity of ascitic fluid on postmortem CT can predict the extent of anasarca.

  10. High-Intensity Interval Exercises' Acute Impact on Heart Rate Variability: Comparison Between Whole-Body and Cycle Ergometer Protocols.

    Science.gov (United States)

    Schaun, Gustavo Z; Del Vecchio, Fabrício B

    2018-01-01

    Schaun, GZ and Del Vecchio, FB. High-intensity interval exercises' acute impact on heart rate variability: comparison between whole-body and cycle ergometer protocols. J Strength Cond Res 32(1): 223-229, 2018-Study aimed to compare the effects of 2 high-intensity interval training (HIIT) protocols on heart rate variability. Twelve young adult males (23.3 ± 3.9 years, 177.8 ± 7.4 cm, 76.9 ± 12.9 kg) volunteered to participate. In a randomized cross-over design, subjects performed 2 HIIT protocols, 1 on a cycle ergometer (Tabata protocol [TBT]; eight 20-second bouts at 170% Pmax interspersed by 10-second rest) and another with whole-body calisthenic exercises (McRae protocol; eight 20-second all-out intervals interspersed by 10-second rest). Heart rate variability outcomes in the time, frequency, and nonlinear domains were assessed on 3 moments: (a) presession; (b) immediately postsession; and (c) 24 hours postsession. Results revealed that RRmean, Ln rMSSD, Ln high frequency (HF), and Ln low frequency (LF) were significantly reduced immediately postsession (p ≤ 0.001) and returned to baseline 24 h after both protocols. In addition, LF/HF ratio was reduced 24 h postsession (p ≤ 0.01) and SD2 was significantly lower immediately postsession only in TBT. Our main finding was that responses from heart rate autonomic control were similar in both protocols, despite different modes of exercise performed. Specifically, exercises resulted in a high parasympathetic inhibition immediately after session with subsequent recovery within 1 day. These results suggest that subjects were already recovered the day after and can help coaches to better program training sessions with such protocols.

  11. Cardiopulmonary response during whole-body vibration training in patients with severe COPD

    OpenAIRE

    Rainer Gloeckl; Petra Richter; Sandra Winterkamp; Michael Pfeifer; Christoph Nell; Jeffrey W. Christle; Klaus Kenn

    2017-01-01

    Several studies in patients with chronic obstructive pulmonary disease (COPD) have shown that whole-body vibration training (WBVT) has beneficial effects on exercise capacity. However, the acute cardiopulmonary demand during WBVT remains unknown and was therefore investigated in this study. Ten patients with severe COPD (forced expiratory volume in 1?s: 38?8% predicted) were examined on two consecutive days. On day one, symptom-limited cardiopulmonary exercise testing was performed on a cycle...

  12. Possibilities of whole-body MRI for investigating musculoskeletal diseases

    International Nuclear Information System (INIS)

    Lenk, S.; Claussen, C.D.; Schlemmer, H.P.; Fischer, S.; Koetter, I.

    2004-01-01

    This contribution outlines possibilities and limitations of whole-body MRI for investigating musculoskeletal diseases. Benefits and drawbacks of the novel whole-body MRI technology are discussed and a possible whole-body MRI sequence protocol for musculoskeletal examinations is proposed. Muscle, joint and bone diseases are discussed in which the application of whole-body MRI may be of advantage. Particularly, polymyositis, muscledystrophy, rheumatoid arthritis, spondylitis ancylosans, multiple trauma, skeletal metastases, multiple myeloma and malignant lymphoma are mentioned. Whole-body MRI opens new advantages for the examination of multifocal musculoskeletal diseases. The clinical benefit of this method for particular diseases has to be evaluated in further studies, however. (orig.) [de

  13. Whole body imaging

    International Nuclear Information System (INIS)

    de Luca, P.C.; Stoddart, H.F.; Jeffries, D.

    1976-01-01

    A whole body imaging system rapidly forms a quality image of the bony structure, soft tissue or specific organs of a patient who has been injected with a suitable radioactive tracer chemical. A radiation detector head assembly includes a number of detector subassemblies, each having a lead collimator with tapered holes for admitting gamma radiation from a small area of the patient to a scintillation crystal that converts the gamma rays admitted by the collimator into visible or ultraviolet energy pulses. A photomultiplier converts these pulses into electrical pulses. A row of equally spaced detector subassemblies reciprocate within a nonreciprocating lead shield along the long axis of the array over a distance substantially equal to the separation between adjacent ones of the small areas. Associated electronic and electromechanical apparatus control the reciprocating motion and the longitudinal motion of the radiation detector head assembly, and process the photodetected signals to produce in a relatively short time a visible image of the radiant energy emanating from the whole body of the patient scanned

  14. Radioprotection by caffeine pre-treatment and post-treatment in the bone marrow chromosomes of mice given whole-body γ-irradiation

    International Nuclear Information System (INIS)

    Farooqi, Z.; Kesavan, P.C.

    1992-01-01

    The effect of caffeine given as pre- and post-treatment in mice exposed to whole-body γ-irradiation (1.5 Gy 60 Co γ-rays) was studied. The pre-treatment was either acute or chronic. The acute dose (5 mg/kg and 15 mg/kg body weight) was in the form of an injection given intraperitoneally, 30 min before irradiation. The chronic administration was in the form of caffeine solution (4.208x10 -3 M and 7.72x10 -4 M) contained in drinking water for 5 weeks prior to radiation exposure. The acute pre-treatment with caffeine reduced the radiation-induced frequency of chromosomal aberrations discernibly, whereas chronic pre-treatment afforded a much more significant degree of radioprotection. The caffeine post-treatment (5 mg/kg and 15 mg/kg body weight) was given in the form of an intraperitoneal injection to the mice immediately following whole-body γ-irradiation. It is noted that both post-treatment concentrations of caffeine also significantly reduced the frequency of chromosomal aberrations induced by γ-rays. These data are briefly discussed in terms of possible mechanistic considerations. (author). 33 refs.; 3 tabs

  15. Radioprotection by caffeine pre-treatment and post-treatment in the bone marrow chromosomes of mice given whole-body [gamma]-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Farooqi, Z.; Kesavan, P.C. (Jawaharlal Nehru Univ., New Delhi (India). School of Life Sciences)

    1992-10-01

    The effect of caffeine given as pre- and post-treatment in mice exposed to whole-body [gamma]-irradiation (1.5 Gy [sup 60]Co [gamma]-rays) was studied. The pre-treatment was either acute or chronic. The acute dose (5 mg/kg and 15 mg/kg body weight) was in the form of an injection given intraperitoneally, 30 min before irradiation. The chronic administration was in the form of caffeine solution (4.208x10[sup -3] M and 7.72x10[sup -4] M) contained in drinking water for 5 weeks prior to radiation exposure. The acute pre-treatment with caffeine reduced the radiation-induced frequency of chromosomal aberrations discernibly, whereas chronic pre-treatment afforded a much more significant degree of radioprotection. The caffeine post-treatment (5 mg/kg and 15 mg/kg body weight) was given in the form of an intraperitoneal injection to the mice immediately following whole-body [gamma]-irradiation. It is noted that both post-treatment concentrations of caffeine also significantly reduced the frequency of chromosomal aberrations induced by [gamma]-rays. These data are briefly discussed in terms of possible mechanistic considerations. (author). 33 refs.; 3 tabs.

  16. Acute non-stochastic effect of very low dose whole-body exposure, a thymidine equivalent serum factor

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; Muehlensiepen, H.; Porschen, W.; Booz, J.

    1982-01-01

    Whole-body irradiation of mice causes the dose-dependent appearance of a humoral factor in blood serum which inhibits incorporation of 125-IUdR into tissue culture cells. This factor appears even at doses below 0.01 Gy gamma irradiation and thus is probably not related to cell death. Data are presented relating this humoral factor to thymidine. Since at low doses the target size for this effect was calculated to be the entire cell, a cellular effect is postulated linking the site of few primary absorption events, anywhere in the cell, with the cellular membrane, thus causing changes in membrane charge, structure and/or fluidity. This may lead to blocking thymidine acceptance by the cell, and thus would cause a pile-up of thymidine in the reutilization pathway in peripheral blood and would give rise to the observed effect. The effect appears as a temporary disturbance of the physiological equilibrium and should not be related at present to any cellular damage. The acute low-dose effect described has implications for the measurement of low-dose exposure by biological dosimeters and on basic research on membrane function. (author)

  17. Whey Protein Supplementation Enhances Whole Body Protein Metabolism and Performance Recovery after Resistance Exercise: A Double-Blind Crossover Study.

    Science.gov (United States)

    West, Daniel W D; Abou Sawan, Sidney; Mazzulla, Michael; Williamson, Eric; Moore, Daniel R

    2017-07-11

    No study has concurrently measured changes in free-living whole body protein metabolism and exercise performance during recovery from an acute bout of resistance exercise. We aimed to determine if whey protein ingestion enhances whole body net protein balance and recovery of exercise performance during overnight (10 h) and 24 h recovery after whole body resistance exercise in trained men. In a double-blind crossover design, 12 trained men (76 ± 8 kg, 24 ± 4 years old, 14% ± 5% body fat; means ± standard deviation (SD)) performed resistance exercise in the evening prior to consuming either 25 g of whey protein (PRO; MuscleTech 100% Whey) or an energy-matched placebo (CHO) immediately post-exercise (0 h), and again the following morning (~10 h of recovery). A third randomized trial, completed by the same participants, involving no exercise and no supplement served as a rested control trial (Rest). Participants ingested [ 15 N]glycine to determine whole body protein kinetics and net protein balance over 10 and 24 h of recovery. Performance was assessed pre-exercise and at 0, 10, and 24 h of recovery using a battery of tests. Net protein balance tended to improve in PRO ( P = 0.064; effect size (ES) = 0.61, PRO vs. CHO) during overnight recovery. Over 24 h, net balance was enhanced in PRO ( P = 0.036) but not in CHO ( P = 0.84; ES = 0.69, PRO vs. CHO), which was mediated primarily by a reduction in protein breakdown (PRO protein supplementation improved MVC (ES = 0.76), REP (ES = 0.44), and peak power (ES = 0.55). In conclusion, whey protein supplementation enhances whole body anabolism, and may improve acute recovery of exercise performance after a strenuous bout of resistance exercise.

  18. Quantitative whole body scintigraphy - a simplified approach

    International Nuclear Information System (INIS)

    Marienhagen, J.; Maenner, P.; Bock, E.; Schoenberger, J.; Eilles, C.

    1996-01-01

    In this paper we present investigations on a simplified method of quantitative whole body scintigraphy by using a dual head LFOV-gamma camera and a calibration algorithm without the need of additional attenuation or scatter correction. Validation of this approach to the anthropomorphic phantom as well as in patient studies showed a high accuracy concerning quantification of whole body activity (102.8% and 97.72%, resp.), by contrast organ activities were recovered with an error range up to 12%. The described method can be easily performed using commercially available software packages and is recommendable especially for quantitative whole body scintigraphy in a clinical setting. (orig.) [de

  19. Acute tolerance of hyperfractionated accelerated total body irradiation

    International Nuclear Information System (INIS)

    Latz, D.; Schraube, P.; Wannenmacher, M.

    1996-01-01

    Background: Acute side effects of total body irradiation lead to intense molestations of the patients. Therefore, it is desirable to take measures to reduce these side effects. In a retrospective study the frequency on acute side effects of a hyperfractionated accelerated total body irradiation was assessed and compared to frequencies of other exposure schedules published in the literature. Additionally the influence of ondansetron on the frequency of nausea and vormiting was investigated. Patients and Method: From 1989 to 1992, 76 patients (47 male, 29 female; median age 38 years) underwent total body irradiation before autologeous bone marrow transplantation. They received 3 daily doses of 1.20 Gy each every 4 h on 4 successive days to a total dose of 14,40 Gy. Thirty-nine patients received 3x8 mg (daily, intravenous or per os) ondansetron during the whole course of irradiation. Results: The most relevant side effects were nausea and vomiting. Patients, who did not receive ondansetron (n=37) showed a nausea and emesis rate of 73%. With ondansetron (n=39) nausea and emesis were reduced to 38%. Also the grade of severity of these side effects was reduced. Conclusions: Ondansetron proved to be an effective medicament for relieving nausea and vormiting during total body irradiation. The results obtained are in concordance with those published in the literature. (orig.) [de

  20. The A.R.L. whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1990-02-01

    This report describes a Whole Body Monitor based on four uncollimated NaI(Tl) detectors in a static geometry in use at the Australian Radiation Laboratory. A detailed discussion is presented on the methodology used to estimate the detector efficiency for any arbitrary source whose shape can be described analytically. This procedure is valid for photon emitters in the range 120 keV to 2.6 MeV. By the use of simple geometric models, this approach is applied to the whole body as well as for certain internal organs. For lower photon energies, a discussion of methods using NaI(Tl) detectors to detect in-vivo sources by analysis of pulse-height spectra, is presented. In addition, the application of the Whole Body Monitor in the study of human calcium metabolism, using the tracer 47 Ca is described. Results of measurments on the natural activity of possible candidates for components of the concrete base of the Whole Body Monitor are presented. 74 refs., 22 tabs., 40 figs

  1. Whole-body monitoring: Goiania case, Brazil

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Dantas, B.M.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: individuals from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1); occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121, 57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was stablished according to the Cs activity present in the body or to the job that will be done. Some body burden activity curves for Cs 137 as a function of the time elapsed from the first measurement, are presented. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity X time curve. (author) [pt

  2. Improvement of measuring techniques with whole-body and partial-body counters

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    Mathematical simulation methods have been applied for optimizing and standardizing the calibration of whole-body and partial-body counters for any nuclide accumulation in the human body. (orig./CB) [de

  3. Treatment of whole-body radiation accident victims

    International Nuclear Information System (INIS)

    Drum, D.E.; Rappeport, J.M.

    1990-01-01

    This paper discusses how whole-body radiation exposure incidents present a number of unique challenges. The acute, nonstochastic effects of high doses of radiation over 25 rads (0.25 Gy) delivered to humans is generally manifest in rather categorical fashion; depending on the dose, either the patient is largely unharmed functionally or he is seriously injured. Radiation initiates microchemical changes within a nanosecond time frame; there exists no specific therapy to stop or reverse the sequence of events that follow. Thus, the range for effective therapeutic intervention is rather small, between 150 to 1500 rad (1.5 to 15 Gy) for humans. Nevertheless, it is likely that a large uncomplicated exposure to as much as 750 rad (7.5 Gy) might be survivable without dramatic measures such as bone marrow transplantation. Review of the available information about past accidents shows that the majority of radiation accidents are mixed injuries

  4. The assessment of whole body bone SPECT in oncology

    International Nuclear Information System (INIS)

    Scortechini, Shonika

    2009-01-01

    Full text: Objectives: To assess the significance and practicability of oncology whole body bone SPECT as part of the standard skeletal survey and its impact on the traditional planar whole body bone imaging protocol. Method: Three consenting oncology patients were injected with a standard adult dose of Tc-99m MOP. Delayed Imaging of whole body sweep and SPECT acquisitions were performed on a Siemens Symbia T6. The patient was positioned supine with arms down with a SPECT scan length covering vortex to thighs. SPECT data was reconstructed and a single whole body zipped file created. Normal SPECT slices along with a cine/MIP of the zipped data were created for review. Results: Both image data sets were reviewed to assess if SPECT provided any further diagnostic clinical information not apparent in planer imaging. In our limited review, whole body SPECT did not add extra value to the planar whole body scans performed; it did however demonstrate vertebral involvement with greater resolution. The processing software and system limitations in seamlessly knitting data sets (creating image artefacts) was a major limiting factor in not pursuing further studies. Conclusion: Both imaging techniques offer differing advantages and limitations, however due to image artefact in the triple knitted SPECT approach with current software technology, it cannot be substituted for whole body imaging at this time.

  5. Advanced CUBIC protocols for whole-brain and whole-body clearing and imaging.

    Science.gov (United States)

    Susaki, Etsuo A; Tainaka, Kazuki; Perrin, Dimitri; Yukinaga, Hiroko; Kuno, Akihiro; Ueda, Hiroki R

    2015-11-01

    Here we describe a protocol for advanced CUBIC (Clear, Unobstructed Brain/Body Imaging Cocktails and Computational analysis). The CUBIC protocol enables simple and efficient organ clearing, rapid imaging by light-sheet microscopy and quantitative imaging analysis of multiple samples. The organ or body is cleared by immersion for 1-14 d, with the exact time required dependent on the sample type and the experimental purposes. A single imaging set can be completed in 30-60 min. Image processing and analysis can take whole-brain neural activities at single-cell resolution using Arc-dVenus transgenic (Tg) mice. CUBIC informatics calculated the Venus signal subtraction, comparing different brains at a whole-organ scale. These protocols provide a platform for organism-level systems biology by comprehensively detecting cells in a whole organ or body.

  6. Effectiveness of Different Rest Intervals Following Whole-Body Vibration on Vertical Jump Performance between College Athletes and Recreationally Trained Females

    Directory of Open Access Journals (Sweden)

    Nicole C. Dabbs

    2015-09-01

    Full Text Available The purpose of this study was to evaluate the effect of different rest intervals following whole-body vibration on counter-movement vertical jump performance. Sixteen females, eight recreationally trained and eight varsity athletes volunteered to participate in four testing visits separated by 24 h. Visit one acted as a familiarization visit where subjects were introduced to the counter-movement vertical jump and whole-body vibration protocols. Visits 2–4 contained 2 randomized conditions. Whole-body vibration was administered in four bouts of 30 s with 30 s rest between bouts. During whole-body vibration subjects performed a quarter squat every 5 s, simulating a counter-movement vertical jump. Whole-body vibration was followed by three counter-movement vertical jumps with five different rest intervals between the vibration exposure and jumping. For a control condition, subjects performed squats with no whole-body vibration. There was a significant (p < 0.05 main effect for time for vertical jump height, peak power output, and relative ground reaction forces, where a majority of individuals max jump from all whole-body vibration conditions was greater than the control condition. There were significant (p < 0.05 group differences, showing that varsity athletes had a greater vertical jump height and peak power output compared to recreationally trained females. There were no significant (p > 0.05 group differences for relative ground reaction forces. Practitioners and/or strength and conditioning coaches may utilize whole-body vibration to enhance acute counter-movement vertical jump performance after identifying individuals optimal rest time in order to maximize the potentiating effects.

  7. Whole body scan system based on γ camera

    International Nuclear Information System (INIS)

    Ma Tianyu; Jin Yongjie

    2001-01-01

    Most existing domestic γ cameras can not perform whole body scan protocol, which is of important use in clinic. The authors designed a set of whole body scan system, which is made up of a scan bed, an ISA interface card controlling the scan bed and the data acquisition software based on a data acquisition and image processing system for γ cameras. The image was obtained in clinical experiment, and the authors think it meets the need of clinical diagnosis. Application of this system in γ cameras can provide whole body scan function at low cost

  8. Neurogenic Effects of Low-Dose Whole-Body HZE (Fe) Ion and Gamma Irradiation.

    Science.gov (United States)

    Sweet, Tara B; Hurley, Sean D; Wu, Michael D; Olschowka, John A; Williams, Jacqueline P; O'Banion, M Kerry

    2016-12-01

    Understanding the dose-toxicity profile of radiation is critical when evaluating potential health risks associated with natural and man-made sources in our environment. The purpose of this study was to evaluate the effects of low-dose whole-body high-energy charged (HZE) iron (Fe) ions and low-energy gamma exposure on proliferation and differentiation of adult-born neurons within the dentate gyrus of the hippocampus, cells deemed to play a critical role in memory regulation. To determine the dose-response characteristics of the brain to whole-body Fe-ion vs. gamma-radiation exposure, C57BL/6J mice were irradiated with 1 GeV/n Fe ions or a static 137 Cs source (0.662 MeV) at doses ranging from 0 to 300 cGy. The neurogenesis was analyzed at 48 h and one month postirradiation. These experiments revealed that whole-body exposure to either Fe ions or gamma radiation leads to: 1. An acute decrease in cell division within the dentate gyrus of the hippocampus, detected at doses as low as 30 and 100 cGy for Fe ions and gamma radiation, respectively; and 2. A reduction in newly differentiated neurons (DCX immunoreactivity) at one month postirradiation, with significant decreases detected at doses as low as 100 cGy for both Fe ions and gamma rays. The data presented here contribute to our understanding of brain responses to whole-body Fe ions and gamma rays and may help inform health-risk evaluations related to systemic exposure during a medical or radiologic/nuclear event or as a result of prolonged space travel.

  9. Study protocol: the effect of whole body vibration on acute unilateral unstable lateral ankle sprain- a biphasic randomized controlled trial.

    Science.gov (United States)

    Baumbach, Sebastian Felix; Fasser, Mariette; Polzer, Hans; Sieb, Michael; Regauer, Markus; Mutschler, Wolf; Schieker, Matthias; Blauth, Michael

    2013-01-14

    Ankle sprains often result in ankle instability, which is most likely caused by damage to passive structures and neuromuscular impairment. Whole body vibration (WBV) is a neuromuscular training method improving those impaired neurologic parameters. The aim of this study is to compare the current gold standard functional treatment to functional treatment plus WBV in patients with acute unilateral unstable inversion ankle sprains. 60 patients, aged 18-40 years, presenting with an isolated, unilateral, acute unstable inversion ankle sprain will be included in this bicentric, biphasic, randomized controlled trial. Samples will be randomized by envelope drawing. All patients will be allowed early mobilization and pain-dependent weight bearing, limited functional immobilization by orthosis, PRICE, NSARDs as well as home and supervised physiotherapy. Supervised physical therapy will take place twice a week, for 30 minutes for a period of 6 weeks, following a standardized intervention protocol. During supervised physical therapy, the intervention group will perform exercises similar to those of the control group, on a side-alternating sinusoidal vibration platform. Two time-dependent primary outcome parameters will be assessed: short-term outcome after six weeks will be postural control quantified by the sway index; mid-term outcome after one year will be assessed by subjective instability, defined by the presence of giving-way attacks. Secondary outcome parameters include: return to pre-injury level of activities, residual pain, recurrence, objective instability, energy/coordination, Foot and Ankle Disability Index and EQ 5D. This is the first trial investigating the effects of WBV in patients with acute soft tissue injury. Inversion ankle sprains often result in ankle instability, which is most likely due to damage of neurological structures. Due to its unique, frequency dependent, influence on various neuromuscular parameters, WBV is a promising treatment method for

  10. Whole-body MR imaging of bone marrow

    International Nuclear Information System (INIS)

    Schmidt, G.P.; Schoenberg, S.O.; Reiser, M.F.; Baur-Melnyk, A.

    2005-01-01

    In clinical routine, multimodality algorithms, including X-ray, computed tomography, scintigraphy and MRI, are used in case of suspected bone marrow malignancy. Skeletal scintigraphy is widely used to asses metastatic disease to the bone, CT is the technique of choice to assess criteria of osseous destruction and bone stability. MRI is the only imaging technique that allows direct visualization of bone marrow and its components with high spatial resolution. The combination of unenhanced T1-weighted-spin echo- and turbo-STIR-sequences have shown to be most useful for the detection of bone marrow abnormalities and are able to discriminate benign from malignant bone marrow changes. Originally, whole-body MRI bone marrow screening was performed in sequential scanning techniques of five body levels with time consuming coil rearrangement and repositioning of the patient. The introduction of a rolling platform mounted on top of a conventional MRI examination table facilitated whole-body MR imaging and, with the use of fast gradient echo, T1-weighted and STIR-imaging techniques, for the first time allowed whole-body imaging within less than one hour. With the development of parallel imaging techniques (PAT) in combination with global matrix coil concepts, acquisition time could be reduced substantially without compromises in spatial resolution, enabling the implementation of more complex and flexible examination protocols. Whole-body MRI represents a new alternative to the stepwise multimodality concept for the detection of metastatic disease, multiple myeloma and lymphoma of the bone with high diagnostic accuracy

  11. The ORNL whole body counter

    International Nuclear Information System (INIS)

    1988-01-01

    This report is a non-technical document intended to provide an individual about to undergo a whole-body radiation count with a general understanding of the counting procedure and with the results obtained. 9 figs

  12. Measurement of Organ Uptake by Whole-Body Counting

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1970-01-01

    This paper reviews methods for the measurement of radioactivity in body organs based on whole-body radioactivity measurements. Such measurements can of course only be used to measure radioactivity in a body organ when the radioactivity is exclusively localized in the organ or when the ratio of radioactivity in the organ to that in the whole body is known from other sources of information. They find particular applications, however, when the organ is so widely dispersed throughout the body that more localized measurement is impossible. Examples of situations in which whole-body radioactivity measurements have been used in this way are cited. The more important techniques used for such measurements are described and their respective advantages and disadvantages indicated. The importance of uniformity of counting efficiency with position of source throughout the body is stressed. Simple systems incorporating sodium iodide crystal scintillation detectors are shown to combine satisfactory sensitivity and uniformity of efficiency for clinical measurements of radioactivity in body organs and have the additional advantage that they can be readily adapted for profile scanning. Systems incorporating plastic or liquid scintillation detectors are less convenient in this respect. (author)

  13. The Influence of Whole-Body Vibration on Creatine Kinase Activity and Jumping Performance in Young Basketball Players

    Science.gov (United States)

    Fachina, Rafael; da Silva, Antônio; Falcão, William; Montagner, Paulo; Borin, João; Minozzo, Fábio; Falcão, Diego; Vancini, Rodrigo; Poston, Brach; de Lira, Claudio

    2013-01-01

    Purpose: To quantify creatine kinase (CK) activity changes across time following an acute bout of whole-body vibration (WBV) and determine the association between changes in CK activity and jumping performance. Method: Twenty-six elite young basketball players were assigned to 3 groups: 36-Hz and 46-Hz vibration groups (G36 and G46, respectively)…

  14. Intercalibration of CDTN and IRD whole body counters

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Alonso, T.C.

    2008-01-01

    Full text: Intercalibration exercises are designed to harmonize analytical techniques and ensure reliability of measurement results performed in a laboratory network. Such strategy helps to improve laboratory performance among participants in future intercomparison exercises, when it is verified the metrological capacity, by determining accuracy, precision and reproducibility of data produced by each laboratory. In Brazil, there are currently four in vivo monitoring systems, located in IRD, in Rio de Janeiro, CDTN, in Belo Horizonte, IPEN, in Sao Paulo and CNAAA, in Angra dos Reis. Such systems, generically referred as whole body counters, aim to detect and quantify radionuclides in organs and tissues for radiological protection purposes and to provide useful information for studies on biokinetic behavior of radionuclides in humans and animals. The objective of this work is to establish a methodology to be applied for intercalibration of whole body counters. The IRD whole body counter is installed in a 15 cm steel shielded room where two NaI(Tl) and four HPGe detectors are calibrated for the determination of radionuclides in the energy range from 10 to 3000 keV. The CDTN whole body counter has one NaI detector set up in a shadow shield configuration, and is able to determine radionuclides emitting photons from 100 to 2000 keV. The intercalibration exercise described in this work was planed for whole body geometry using the scintillation detectors available in both laboratories. It was used a thin glass vial containing 2,6615 g of a solution of four gamma emitters ( 57 Co, 137 Cs, 54 Mn, 65 Zn), supplied by the National Laboratory for Metrology of Ionizing Radiation (LNMRI-IRD). The glass vial was measured in the same geometry in both IRD and CDTN whole body counters, being positioned at 31,5 cm distance from the NaI(Tl) detector of each laboratory. The calibration curves (photo peak channel and Efficiency vs Energy) of each detection system were compared. The

  15. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  16. Human whole body cold adaptation.

    NARCIS (Netherlands)

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  17. Time-efficient, high-resolution, whole brain three-dimensional macromolecular proton fraction mapping.

    Science.gov (United States)

    Yarnykh, Vasily L

    2016-05-01

    Macromolecular proton fraction (MPF) mapping is a quantitative MRI method that reconstructs parametric maps of a relative amount of macromolecular protons causing the magnetization transfer (MT) effect and provides a biomarker of myelination in neural tissues. This study aimed to develop a high-resolution whole brain MPF mapping technique using a minimal number of source images for scan time reduction. The described technique was based on replacement of an actually acquired reference image without MT saturation by a synthetic one reconstructed from R1 and proton density maps, thus requiring only three source images. This approach enabled whole brain three-dimensional MPF mapping with isotropic 1.25 × 1.25 × 1.25 mm(3) voxel size and a scan time of 20 min. The synthetic reference method was validated against standard MPF mapping with acquired reference images based on data from eight healthy subjects. Mean MPF values in segmented white and gray matter appeared in close agreement with no significant bias and small within-subject coefficients of variation (maps demonstrated sharp white-gray matter contrast and clear visualization of anatomical details, including gray matter structures with high iron content. The proposed synthetic reference method improves resolution of MPF mapping and combines accurate MPF measurements with unique neuroanatomical contrast features. © 2015 Wiley Periodicals, Inc.

  18. Development of fibrosis in dogs as a late consequence of whole-body X-irradiation

    International Nuclear Information System (INIS)

    Calvo, W.; Fliedner, T.M.; Steinbach, I.; Alcober, V.; Nothdurft, W.; Fache, I.

    1978-01-01

    Dogs wre whole-body irradiated with a single mid-line dose of 1200 R at 300 kV. This high dose will kill non-treated animals within a few days. To save these animals, leukocytes were previously collected during a four-hour leukapheresis using a continuous-flow centrifuge and were stored under liquid nitrogen. Shortly after the whole-body irradiation each dog received its own cryopreserved cells thawed immediately beforehand. The dogs received between 0.32x10 9 and 1.63x10 9 mononuclear blood cells per kilogram of body weight. The number of colony-forming cells contained in the transfusate ranged between 0.19x10 5 and 1.38x10 5 per kilogram of body weight. This blood stem transfusion, together with general supportive therapy, enabled the dogs to overcome the acute radiation syndrome and to recover. The dogs were subsequently sacrificed in two groups after observation for about 260 days or 700-898 days respectively. Pathological findings are described. A particular situation existed in the marrow, whre non-irradiated stem cells had colonized bone cavities containing irradiated stroma. Progressive fibrosis developed in the endosteal areas of the bone cavities in most of the animals. (author)

  19. Proton MR spectroscopy in patients with acute temporal lobe seizures.

    Science.gov (United States)

    Castillo, M; Smith, J K; Kwock, L

    2001-01-01

    Decreases in N-acetyl aspartate (NAA) as seen by proton MR spectroscopy are found in hippocampal sclerosis, and elevated levels of lipids/lactate have been observed after electroconvulsive therapy. Our purpose was to determine whether increased levels of lipids/lactate are found in patients with acute seizures of hippocampal origin. Seventeen patients with known temporal lobe epilepsy underwent proton MR spectroscopy of the mesial temporal lobes within 24 hours of their last seizure. Four of them were restudied when they were seizure-free. Five healthy individuals were used as control subjects. All MR spectroscopy studies were obtained using a single-voxel technique with TEs of 135 and 270. The relationship between the presence of lipids/lactate and seizures was tested using Fisher's exact test. Mean and standard deviations for NAA/creatine (Cr) were obtained in the hippocampi in patients with seizures on initial and follow-up studies and these values were compared with those in the control subjects. Seizure lateralization was obtained in 15 patients. Of the 17 seizure locations that involved hippocampi, 16 showed lipids/lactate by proton MR spectroscopy. Of the 13 hippocampi not directly affected by seizures, 10 showed no lipids/lactate and three showed lipids/lactate. The relationship between lipids/lactate and seizure location was confirmed. A comparison of NAA/Cr ratios for the involved hippocampi with those in control subjects showed significant differences on initial MR spectroscopy; however, no significant difference was found between acute and follow-up NAA/Cr ratios in hippocampi affected by seizures. Lipids/lactate were present in the hippocampi of patients with acute seizures and decreased when the patients were seizure-free. Thus, lipids/lactate may be a sensitive marker for acute temporal lobe seizures.

  20. Whey Protein Supplementation Enhances Whole Body Protein Metabolism and Performance Recovery after Resistance Exercise: A Double-Blind Crossover Study

    Directory of Open Access Journals (Sweden)

    Daniel W. D. West

    2017-07-01

    Full Text Available No study has concurrently measured changes in free-living whole body protein metabolism and exercise performance during recovery from an acute bout of resistance exercise. We aimed to determine if whey protein ingestion enhances whole body net protein balance and recovery of exercise performance during overnight (10 h and 24 h recovery after whole body resistance exercise in trained men. In a double-blind crossover design, 12 trained men (76 ± 8 kg, 24 ± 4 years old, 14% ± 5% body fat; means ± standard deviation (SD performed resistance exercise in the evening prior to consuming either 25 g of whey protein (PRO; MuscleTech 100% Whey or an energy-matched placebo (CHO immediately post-exercise (0 h, and again the following morning (~10 h of recovery. A third randomized trial, completed by the same participants, involving no exercise and no supplement served as a rested control trial (Rest. Participants ingested [15N]glycine to determine whole body protein kinetics and net protein balance over 10 and 24 h of recovery. Performance was assessed pre-exercise and at 0, 10, and 24 h of recovery using a battery of tests. Net protein balance tended to improve in PRO (P = 0.064; effect size (ES = 0.61, PRO vs. CHO during overnight recovery. Over 24 h, net balance was enhanced in PRO (P = 0.036 but not in CHO (P = 0.84; ES = 0.69, PRO vs. CHO, which was mediated primarily by a reduction in protein breakdown (PRO < CHO; P < 0.01. Exercise decreased repetitions to failure (REP, maximal strength (MVC, peak and mean power, and countermovement jump performance (CMJ at 0 h (all P < 0.05 vs. Pre. At 10 h, there were small-to-moderate effects for enhanced recovery of the MVC (ES = 0.56, mean power (ES = 0.49, and CMJ variables (ES: 0.27–0.49 in PRO. At 24 h, protein supplementation improved MVC (ES = 0.76, REP (ES = 0.44, and peak power (ES = 0.55. In conclusion, whey protein supplementation enhances whole body anabolism, and may improve acute recovery of

  1. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  2. Whole body MRI in children; Ganzkoerper-MRT bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Juergen F.; Tsiflikas, Ilias [Tuebingen Univ. (Germany). Bereich Kinderradiologie

    2014-09-15

    In pediatric patients whole body MRI has a relevant impact on both, diagnostic work-up and treatment. Using adapted sequence protocols comprehensive imaging without radiation exposure is possible avoiding additional examinations in many cases. Especially in bone marrow the differentiation between normal and abnormal finding can be difficult, therefore the knowledge of normal maturing of organs is important. Whole body diffusion weighted imaging particularly in neuroblastomas or sarcomas improves the low specificity of conventional MR-protocols. Technical prerequisites, examination protocol and strategies, image interpretation, indications and clinical relevance as well as advantages and disadvantages of whole body MRI will be discussed on the basis of application-oriented cases and the literature.

  3. Study protocol: the effect of whole body vibration on acute unilateral unstable lateral ankle sprain- a biphasic randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Baumbach Sebastian Felix

    2013-01-01

    Full Text Available Abstract Background Ankle sprains often result in ankle instability, which is most likely caused by damage to passive structures and neuromuscular impairment. Whole body vibration (WBV is a neuromuscular training method improving those impaired neurologic parameters. The aim of this study is to compare the current gold standard functional treatment to functional treatment plus WBV in patients with acute unilateral unstable inversion ankle sprains. Methods/Design 60 patients, aged 18–40 years, presenting with an isolated, unilateral, acute unstable inversion ankle sprain will be included in this bicentric, biphasic, randomized controlled trial. Samples will be randomized by envelope drawing. All patients will be allowed early mobilization and pain-dependent weight bearing, limited functional immobilization by orthosis, PRICE, NSARDs as well as home and supervised physiotherapy. Supervised physical therapy will take place twice a week, for 30 minutes for a period of 6 weeks, following a standardized intervention protocol. During supervised physical therapy, the intervention group will perform exercises similar to those of the control group, on a side-alternating sinusoidal vibration platform. Two time-dependent primary outcome parameters will be assessed: short-term outcome after six weeks will be postural control quantified by the sway index; mid-term outcome after one year will be assessed by subjective instability, defined by the presence of giving-way attacks. Secondary outcome parameters include: return to pre-injury level of activities, residual pain, recurrence, objective instability, energy/coordination, Foot and Ankle Disability Index and EQ 5D. Discussion This is the first trial investigating the effects of WBV in patients with acute soft tissue injury. Inversion ankle sprains often result in ankle instability, which is most likely due to damage of neurological structures. Due to its unique, frequency dependent, influence on various

  4. Human and animal studies: portals into the whole body and whole population response

    Science.gov (United States)

    Human and animal studies: portals into the whole body and whole population response Michael C. Madden1 and Brett Winters21US Environmental Protection Agency and 2University of North Carolina Human Studies Facility, Chapel Hill, North Carolina, USA Studies involving collection and...

  5. Does acute exercise affect the performance of whole-body, psychomotor skills in an inverted-U fashion? A meta-analytic investigation.

    Science.gov (United States)

    McMorris, Terry; Hale, Beverley J; Corbett, Jo; Robertson, Kevin; Hodgson, Christopher I

    2015-03-15

    The primary purpose of this study was to examine, using meta-analytical measures, whether research into the performance of whole-body, psychomotor tasks following moderate and heavy exercise demonstrates an inverted-U effect. A secondary purpose was to compare the effects of acute exercise on tasks requiring static maintenance of posture versus dynamic, ballistic skills. Moderate intensity exercise was determined as being between 40% and 79% maximum power output (ẆMAX) or equivalent, while ≥80% ẆMAX was considered to be heavy. There was a significant difference (Zdiff=4.29, p=0.001, R(2)=0.42) between the mean effect size for moderate intensity exercise (g=0.15) and that for heavy exercise size (g=-0.86). These data suggest a catastrophe effect during heavy exercise. Mean effect size for static tasks (g=-1.24) was significantly different (Zdiff=3.24, p=0.001, R(2)=0.90) to those for dynamic/ballistic tasks (g=-0.30). The result for the static versus dynamic tasks moderating variables point to perception being more of an issue than peripheral fatigue for maintenance of static posture. The difference between this result and those found in meta-analyses examining the effects of acute exercise on cognition shows that, when perception and action are combined, the complexity of the interaction induces different effects to when cognition is detached from motor performance. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. National survey of human body radioactivity measured by a mobile whole-body counter and installed whole-body counters

    International Nuclear Information System (INIS)

    Boddy, K.; Fenwick, J.D.; McKenzie, A.L.

    1989-05-01

    Body radioactivity in the general public has been measured in 2339 volunteers throughout the U.K. A mobile whole-body monitor visited collaborating Medical Physics Departments and data were also contributed by Medical Physics Departments possessing installed counters. Levels of body radiocaesium ranged from below detection level to 4149 Bq. Radiocaesium levels were normalised by dividing by the content of natural body potassium-40. In all cases, the dose rate to the body from radiocaesium was less than that from potassium-40. Radiocaesium levels were 2-3 times higher in N.W. England, Scotland and N. Wales than the rest of the country, but this factor is much less than the variation in deposition of Chernobyl radiocaesium. This discrepancy may be accounted for by the nationwide distribution of foodstuffs. At all sites where volunteers were monitored, the ratio of caesium-137/caesium-134 was consistent with a radiocaesium intake attributable primarily to fallout from the Chernobyl fire. (author)

  7. whole body vibration and spinal stabilisation

    African Journals Online (AJOL)

    A range of exercise modalities is used in the rehabilitation of indi- viduals with chronic lower ... effects of whole body vibration (WBV) therapy and conventional ... with musculoskeletal, sensory, emotional, cognitive and behavioural components ...

  8. Whole-body irradiation in case of malignant lymphomas of low malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Labedzki, L; Schmidt, R E; Hartlapp, J H; Illiger, H J; Frommhold, H; Boldt, I

    1982-04-01

    27 consecutive patients with malignant lymphomas were submittet to whole-body irradiations with doses of 0.5 to 3 Gy. Among these patients ten had been treated before. There were two complete and 16 partial remissions. The condition of five patients could not be considerably improved. Four patients showed a tumor progression during the time of bone marrow depression. The remission period was 11.5 (3 to 22 +) months. The hematologic side effects were considerable; in ten cases, the whole-body irradiation could not be continued because of a thrombocytopenia or an aplastic syndrome. A remarkable fact was the appearance of symptoms similar to that of lupus erythematodes in two patients. An inefficacy of whole-body irradiation did not exclude a response to subsequent chemotherapy. Our own experiences allow to make the following conclusion: in most of all patients with malignant lymphomas of low malignancy a measurable tumor reduction is achieved by whole-body irradiation. Because of the hematologic side effects a whole-body irradiation should be applied only in cases of malignant lymphomas of low malignancy the slow growth of which is proved by observation and which have not been treated before. The thrombocyte numbers should be above 100 000/..mu..l before therapy. Otherwise, the whole-body irradiation has to be stopped before the intended effective dose is reached because of an inevitably developing thrombocytopenia. A whole-body irradiation in case of a malignant lymphoma of low grade malignancy necessitates strict follow-up examinations conducted at regular intervals for a period of at least six weeks after the irradiation. The whole-body irradiation should never be applied as ultima ratio.

  9. Automatic anatomy recognition in whole-body PET/CT images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huiqian [College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China and Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu; Odhner, Dewey; Tong, Yubing; Torigian, Drew A. [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Zhao, Liming [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 and Research Center of Intelligent System and Robotics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China)

    2016-01-15

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  10. Automatic anatomy recognition in whole-body PET/CT images

    International Nuclear Information System (INIS)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.; Zhao, Liming

    2016-01-01

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  11. Whole-body impedance control of wheeled humanoid robots

    CERN Document Server

    Dietrich, Alexander

    2016-01-01

    Introducing mobile humanoid robots into human environments requires the systems to physically interact and execute multiple concurrent tasks. The monograph at hand presents a whole-body torque controller for dexterous and safe robotic manipulation. This control approach enables a mobile humanoid robot to simultaneously meet several control objectives with different pre-defined levels of priority, while providing the skills for compliant physical contacts with humans and the environment. After a general introduction into the topic of whole-body control, several essential reactive tasks are developed to extend the repertoire of robotic control objectives. Additionally, the classical Cartesian impedance is extended to the case of mobile robots. All of these tasks are then combined and integrated into an overall, priority-based control law. Besides the experimental validation of the approach, the formal proof of asymptotic stability for this hierarchical controller is presented. By interconnecting the whole-body ...

  12. Proton MR spectroscopy and MR imaging in acute and chronic multiple sclerosis - ringlike appearances in acute plaques

    Energy Technology Data Exchange (ETDEWEB)

    Landtblom, A M [Dept. of Clinical Neuroscience, Linkoeping Univ. Hospital (Sweden); Sjoeqvist, L [Dept. of Radiation Physics, Linkoeping Univ. Hospital (Sweden); Soederfeldt, B [Dept. of Clinical Neuroscience, Linkoeping Univ. Hospital (Sweden); Nyland, H [Dept. of Neurology, Haukeland Hospital, Bergen (Norway); Thuomas, K Aa [Dept. of Radiology, Linkoeping Univ. Hospital (Sweden)

    1995-05-01

    We wanted to compare the metabolite status of brain lesions in different clinical subtypes of multiple sclerosis (MS). Two acute MS lesions with ringlike appearances were also investigated. Twenty-three clinically stable MS patients, 2 patients with acute relapses, and 15 healthy individuals were examined by MR imaging and localized proton MRS. No metabolite differences were seen in plaques of different subtypes. Decreased NAA/Cr and NAA/choline ratios as well as increased inositol/CR ratios were observed in the plaques of the clinically stable or chronic active MS patients as compared with controls. The ring plaques had hyperintense cores with surrounding halos, separated from the cores by rings with low signal intensity in T2-weighted images. The core exhibited a prolonged T2 relaxation time. Proton spectra initially contained lactate. No differences between the metabolite status of nonacute plaques in different clinical subtypes could be detected. The ring plaques contained lactate signals indicating oedema, inflammation, and macrophage invasion, and may be transition forms between acute oedematous lesions and chronic demyelinated plaques. (orig.).

  13. Whole-body function-scintigraphic investigations for the determination of reginal blood volumina and their variations

    International Nuclear Information System (INIS)

    Mostbeck, A.; Partsch, H.

    1976-01-01

    Changes of regional blood volume in the different parts of the body were observed by functional whole body scanning after injection of a tracer which remains sufficiently in the vascular beds to enable acute examinations sup(99m)Tc. In 21 persons changes of regional blood volume compression of both legs) and by pharmacological influences (dihydroergotamine, nifedipine, nitroglycerin, noradrenalin, dopamin). In both venous occlusion and compression of the legs a reciprocal relationship was observed between the blood volume of the legs and that of the central regions of the body. Dihydroergotamine, noradrenalin and dopamin caused a displacement of blood volume towards the central regions. After the application of nitroglycerin there was an increase of blood volume in the arms and in the legs and a distinct decrease of the thoracal blood volume

  14. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  15. The whole-body counter of the radiation centre Giessen

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    The layout of the whole-body counter at the institute for biophysics of the Giessen radiation centre is decribed. With suitable collimators, the whole-body counter may be used to determine the radioactivity in human and animal organs. The shielding and the measuring and waiting rooms for the patients are described with regard to their technical details. The whole-body counting system enables the radioactivity and the retention of various radioisotopes (e.g. 58 Co-vitamin B 12 , 40 K, 54 Mn, 137 Co, 131 J, 22 Na) to be measured. The estimation of the radiation exposure due to different types of examinations in nuclear medicine, in terms of the critical organs for each type of examination, is very accurate with this counting device. (GSE) [de

  16. Whole-body intravoxel incoherent motion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Wurnig, Moritz C.; Eberhardt, Christian; Guggenberger, Roman; Boss, Andreas [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Luechinger, Roger [University and ETH Zurich, Institute of Biomedical Technology, Zurich (Switzerland)

    2015-07-15

    To investigate the technical feasibility of whole-body intravoxel incoherent motion (IVIM) imaging. Whole-body MR images of eight healthy volunteers were acquired at 3T using a spin-echo echo-planar imaging sequence with eight b-values. Coronal parametrical whole-body maps of diffusion (D), pseudodiffusion (D*), and the perfusion fraction (F{sub p}) were calculated. Image quality was rated qualitatively by two independent radiologists, and inter-reader reliability was tested with intra-class correlation coefficients (ICCs). Region of interest (ROI) analysis was performed in the brain, liver, kidney, and erector spinae muscle. Depiction of anatomic structures was rated as good on D maps and good to fair on D* and F{sub p} maps. Exemplary mean D (10{sup -3} mm{sup 2}/s), D* (10{sup -3} mm{sup 2}/s) and F{sub p} (%) values (± standard deviation) of the renal cortex were as follows: 1.7 ± 0.2; 15.6 ± 6.5; 20.9 ± 4.4. Inter-observer agreement was ''substantial'' to ''almost perfect'' (ICC = 0.80 - 0.92). The coefficient of variation of D* was significantly lower with the proposed algorithm compared to the conventional algorithm (p < 0.001), indicating higher stability. The proposed IVIM protocol allows computation of parametrical maps with good to fair image quality. Potential future clinical applications may include characterization of widespread disease such as metastatic tumours or inflammatory myopathies. (orig.)

  17. Detection of metastatic thyroid carcinoma through whole body counting

    International Nuclear Information System (INIS)

    Novenario, H.S.; Pascacio, F.M.; Cruz, Benjamin de la; Anden, A.B.

    Whole body counters are not only used in measuring radioactivity in the body for radiation protection purposes but also in the measurement of iron absorption, body potassium and cesium, chronic blood loss, and also in the determination of the effectiveness of surgery, thyroid hormone and radioactive iodine therapy in thyroid carcinoma. This report deals with our experience in the use of a shadow-shield whole body counter in the determination of I-131 uptake by metastatic lesions of cancer of thyroid after total thyroidectomy and ablation therapy with I-131. This study was undertaken jointly by the Department of Nuclear Medicine, Veterans Memorial Hospital and the Biomedical Research Division of the Philippine Atomic Energy Commission. Preliminary results indicate that the 22 patients who underwent whole body counting after total thyroidectomy I-131 ablation therapy, 9 patients had elevated percentage retention of I-131, 10 patients with normal values and 3 patients with rising values. Foci of I-131 concentration in those with elevated and rising percentage concentration values were seen in the thyroidal bed scintiscans, while the 10 patients with normal values had negative scintiscans. The results of our observations confirm the results obtained by other workers abroad. Our preliminary results indicate that with the use of whole body counters a sensitive method of assessing whether functioning metastatic lesion of cancer of the thyroid still exist after total thyroidectomy and I-131 ablation therapy can be provided. (author)

  18. The effects of whole body vibration combined biofeedback postural control training on the balance ability and gait ability in stroke patients.

    Science.gov (United States)

    Uhm, Yo-Han; Yang, Dae-Jung

    2017-11-01

    [Purpose] The purpose of this study was to examine the effect of biofeedback postural control training using whole body vibration in acute stroke patients on balance and gait ability. [Subjects and Methods] Thirty stroke patients participated in this study and were divided into a group of 10, a group for biofeedback postural control training combined with a whole body vibration, one for biofeedback postural control training combined with an aero-step, and one for biofeedback postural control training. Biorescue was used to measure the limits of stability, balance ability, and Lukotronic was used to measure step length, gait ability. [Results] In the comparison of balance ability and gait ability between the groups for before and after intervention, Group I showed a significant difference in balance ability and gait ability compared to Groups II and III. [Conclusion] This study showed that biofeedback postural control training using whole body vibration is effective for improving balance ability and gait ability in stroke patients.

  19. Whole-body magnetic resonance imaging in axial spondyloarthritis

    DEFF Research Database (Denmark)

    Krabbe, Simon; Østergaard, Mikkel; Eshed, Iris

    2018-01-01

    Objective. To investigate whether adalimumab (ADA) reduces whole-body (WB-) magnetic resonance imaging (MRI) indices for inflammation in the entheses, peripheral joints, sacroiliac joints, spine, and the entire body in patients with axial spondyloarthritis (axSpA). Methods. An investigator-initia...

  20. Whole body plastination, intra-organ heterogeneity, and tissue based diagnosis – a survey

    Directory of Open Access Journals (Sweden)

    Gunther von Hagens

    2018-04-01

    Full Text Available  Background: The corpse is the final structural relict of life. Its detailed analysis, the autopsy formed the basis and contributed significantly to our understanding of location, function and interaction of organs in man. Today, autopsies are performed rarely. They have been replaced by radiological in vivo visualization techniques and the analysis of organ excisions and biopsies. Which attributes do whole body preservations possess in this context? Techniques of Whole Body Analysis: In vivo imaging transfers the appearance of body organs and cellular structures in virtual images. The patient’s exposure to X-rays, fundamental particles (electrons, positrons, etc., strong magnetic fields (nuclear resonance, or ultra sounds release the corresponding signals. The obtained images are interpreted in search for local abnormalities such as cancer, acute and chronic infections, inborn errors, hypertrophy or atrophy. Autopsies require the removal and visual inspection of organs shortly after the victim’s death. In addition, tissue probes of suspicious lesions are fixed and microscopically analyzed. The search for gene or protein abnormalities are added dependent upon the clinical history and gross findings. The whole body plastination is performed in separated steps which include fixation, anatomical dissection, forced polymer impregnation, positioning and curing. Organs and other tissue structures can be taken out of the body and separately demonstrated, or aligned and fixed within the body. Additional tissue examinations are possible at this stage, which is followed by hardening and fixation of the still flexible body. Fixation is done with heat, light or gas.   Results and Interpretation: Tissue conservation is a prerequisite to analyze and investigate in diagnosis and forecast of disease occurrence and behaviour. In history, autopsies have opened the door to localize the position and to understand the functions of organs. Today, they have been

  1. Human whole body cold adaptation.

    Science.gov (United States)

    Daanen, Hein A M; Van Marken Lichtenbelt, Wouter D

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000 y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations, but also physiological adaptations to cold. Dedicated studies show that repeated whole body exposure of individual volunteers, mainly Caucasians, to severe cold results in reduced cold sensation but no major physiological changes. Repeated cold water immersion seems to slightly reduce metabolic heat production, while repeated exposure to milder cold conditions shows some increase in metabolic heat production, in particular non-shivering thermogenesis. In conclusion, human cold adaptation in the form of increased metabolism and insulation seems to have occurred during recent evolution in populations, but cannot be developed during a lifetime in cold conditions as encountered in temperate and arctic regions. Therefore, we mainly depend on our behavioral skills to live in and survive the cold.

  2. Whole-Body and Hepatic Insulin Resistance in Obese Children

    Science.gov (United States)

    Ibarra-Reynoso, Lorena del Rocío; Pisarchyk, Liudmila; Pérez-Luque, Elva Leticia; Garay-Sevilla, Ma. Eugenia; Malacara, Juan Manuel

    2014-01-01

    Background Insulin resistance may be assessed as whole body or hepatic. Objective To study factors associated with both types of insulin resistance. Methods Cross-sectional study of 182 obese children. Somatometric measurements were registered, and the following three adiposity indexes were compared: BMI, waist-to-height ratio and visceral adiposity. Whole-body insulin resistance was evaluated using HOMA-IR, with 2.5 as the cut-off point. Hepatic insulin resistance was considered for IGFBP-1 level quartiles 1 to 3 (HOMA-IR was negatively associated with IGFBP-1 and positively associated with BMI, triglycerides, leptin and mother's BMI. Girls had increased HOMA-IR. IGFBP-1 was negatively associated with waist-to-height ratio, age, leptin, HOMA-IR and IGF-I. We did not find HOMA-IR or IGFBP-1 associated with fatty liver. Conclusion In school-aged children, BMI is the best metric to predict whole-body insulin resistance, and waist-to-height ratio is the best predictor of hepatic insulin resistance, indicating that central obesity is important for hepatic insulin resistance. The reciprocal negative association of IGFBP-1 and HOMA-IR may represent a strong interaction of the physiological processes of both whole-body and hepatic insulin resistance. PMID:25411786

  3. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  4. Melatonin, a potential effective protector in whole body γ-irradiated rats

    International Nuclear Information System (INIS)

    Tawfik, S.S; El-Nashar, D.E; Ahmed, M.M; Hanafy, Z.E

    2010-01-01

    Melatonin (N-acetyl-5-methoxytryptamine), the chief hormone of pineal gland, is widely distributed in animal kingdom. It is claimed for its antioxidant and free radical properties. The present study aimed to examine the radio protective potentiality and efficacy of melatonin against damages induced in whole body γ-irradiated rats. Animals received melatonin (10 mg/ kg body wt/ day) for 10 successive days pre-exposure to 3 Gy of γ-radiation (acute dose). Rats sacrificed at 10 and 20 days post the irradiation time. The results revealed that the prolonged administration of melatonin has ameliorated the radiation- induced depletion in brain, testis and serum glutathione (GSH) level and a decrease in serum glutathione peroxidase (GPX) activity when compared with their matched values in irradiated rats. In addition, remarkable decreases in the concentration of lipid peroxidation (LPO) product; malondialdhyde (MDA) was observed in brain, testis and serum of rats received melatonin pre-radiation exposure. As well as, significant decreases in disulphide glutathione (GSSG) were observed in serum.Histopathological examination of brain and testis showed that administration of melatonin pre-irradiation according to the present regimen has attenuated radiation induced tissue damages and improved tissue architecture. Cytogenetically, the chromosomal aberration (CA) assay in bone marrow pointed out a significant difference between rats received melatonin pre-irradiation and γ-irradiated rats in most CA types. Accordingly, it could be postulated the tissue diversity and cytogenetic impact of the administrated melatonin against acute ion syndrome in rat model.

  5. Whole body vibration improves cognition in healthy young adults.

    Directory of Open Access Journals (Sweden)

    G Ruben H Regterschot

    Full Text Available This study investigated the acute effects of passive whole body vibration (WBV on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5±2.2 years underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on the Stroop Color-Block Test (CBT, Stroop Color-Word Interference Test (CWIT, Stroop Difference Score (SDS and Digit Span Backward task (DSBT was measured. In half of the passive WBV and control sessions the test order was CBT-CWIT-DSBT, and DSBT-CBT-CWIT in the other half. Passive WBV improved CWIT (p = 0.009; effect size r = 0.20 and SDS (p = 0.034; r = 0.16 performance, but only when the CBT and CWIT preceded the DSBT. CBT and DSBT performance did not change. This study shows that two minutes passive WBV has positive acute effects on attention and inhibition in young adults, notwithstanding their high cognitive functioning which could have hampered improvement. This finding indicates the potential of passive WBV as a cognition-enhancing therapy worth further evaluation, especially in persons unable to perform active forms of exercise.

  6. Whole body vibration improves cognition in healthy young adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Van Heuvelen, Marieke J G; Zeinstra, Edzard B; Fuermaier, Anselm B M; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van Der Zee, Eddy A

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5±2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on the Stroop Color-Block Test (CBT), Stroop Color-Word Interference Test (CWIT), Stroop Difference Score (SDS) and Digit Span Backward task (DSBT) was measured. In half of the passive WBV and control sessions the test order was CBT-CWIT-DSBT, and DSBT-CBT-CWIT in the other half. Passive WBV improved CWIT (p = 0.009; effect size r = 0.20) and SDS (p = 0.034; r = 0.16) performance, but only when the CBT and CWIT preceded the DSBT. CBT and DSBT performance did not change. This study shows that two minutes passive WBV has positive acute effects on attention and inhibition in young adults, notwithstanding their high cognitive functioning which could have hampered improvement. This finding indicates the potential of passive WBV as a cognition-enhancing therapy worth further evaluation, especially in persons unable to perform active forms of exercise.

  7. Between-centre variability versus variability over time in DXA whole body measurements evaluated using a whole body phantom

    Energy Technology Data Exchange (ETDEWEB)

    Louis, Olivia [Department of Radiology, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)]. E-mail: olivia.louis@az.vub.ac.be; Verlinde, Siska [Belgian Study Group for Pediatric Endocrinology (Belgium); Thomas, Muriel [Belgian Study Group for Pediatric Endocrinology (Belgium); De Schepper, Jean [Department of Pediatrics, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)

    2006-06-15

    This study aimed to compare the variability of whole body measurements, using dual energy X-ray absorptiometry (DXA), among geographically distinct centres versus that over time in a given centre. A Hologic-designed 28 kg modular whole body phantom was used, including high density polyethylene, gray polyvinylchloride and aluminium. It was scanned on seven Hologic QDR 4500 DXA devices, located in seven centres and was also repeatedly (n = 18) scanned in the reference centre, over a time span of 5 months. The mean between-centre coefficient of variation (CV) ranged from 2.0 (lean mass) to 5.6% (fat mass) while the mean within-centre CV ranged from 0.3 (total mass) to 4.7% (total area). Between-centre variability compared well with within-centre variability for total area, bone mineral content and bone mineral density, but was significantly higher for fat (p < 0.001), lean (p < 0.005) and total mass (p < 0.001). Our results suggest that, even when using the same device, the between-centre variability remains a matter of concern, particularly where body composition is concerned.

  8. Whole body MR imaging in diabetes

    International Nuclear Information System (INIS)

    Weckbach, Sabine; Schoenberg, Stefan O.

    2009-01-01

    Diabetes mellitus is a major cardiovascular risk factor and one of the major causes for morbidity and mortality worldwide. Diabetic complications have not only major impact on the quality of life of diabetic patients, but are also potentially life-threatening. Therefore prevention, diagnosis and therapy of these long-term complications are of high importance. However, diagnosis of the variety of complications from diabetes mellitus remains a diagnostic challenge and usually several diagnostic steps are necessary to diagnose or exclude these complications. In the last years whole body magnetic resonance imaging (WB-MRI) including whole body magnetic resonance angiography (WB-MRA) has been introduced for cardiovascular imaging and is now increasingly applied in clinical routine for the workup of patients with cardiovascular disease and for cardiovascular screening. The article summarizes rationales for WB-MRI in diabetes mellitus, technical concepts of disease specific cardiovascular WB-MRI in diabetes mellitus and discusses potential clinical consequences.

  9. Parasympathetic activity and blood catecholamine responses following a single partial-body cryostimulation and a whole-body cryostimulation.

    Directory of Open Access Journals (Sweden)

    Christophe Hausswirth

    Full Text Available The aim of this study was to compare the effects of a single whole-body cryostimulation (WBC and a partial-body cryostimulation (PBC (i.e., not exposing the head to cold on indices of parasympathetic activity and blood catecholamines. Two groups of 15 participants were assigned either to a 3-min WBC or PBC session, while 10 participants constituted a control group (CON not receiving any cryostimulation. Changes in thermal, physiological and subjective variables were recorded before and during the 20-min after each cryostimulation. According to a qualitative statistical analysis, an almost certain decrease in skin temperature was reported for all body regions immediately after the WBC (mean decrease±90% CL, -13.7±0.7°C and PBC (-8.3±0.3°C, which persisted up to 20-min after the session. The tympanic temperature almost certainly decreased only after the WBC session (-0.32±0.04°C. Systolic and diastolic blood pressures were very likely increased after the WBC session, whereas these changes were trivial in the other groups. In addition, heart rate almost certainly decreased after PBC (-10.9% and WBC (-15.2% sessions, in a likely greater proportion for WBC compared to PBC. Resting vagal-related heart rate variability indices (the root-mean square difference of successive normal R-R intervals, RMSSD, and high frequency band, HF were very likely increased after PBC (RMSSD: +54.4%, HF: +138% and WBC (RMSSD: +85.2%, HF: +632% sessions without any marked difference between groups. Plasma norepinephrine concentrations were likely to very likely increased after PBC (+57.4% and WBC (+76.2%, respectively. Finally, cold and comfort sensations were almost certainly altered after WBC and PBC, sensation of discomfort being likely more pronounced after WBC than PBC. Both acute cryostimulation techniques effectively stimulated the autonomic nervous system (ANS, with a predominance of parasympathetic tone activation. The results of this study also suggest

  10. Analysis of whole-body vibration on rheological models for tissues

    Science.gov (United States)

    Neamţu, A.; Simoiu, D.; Nyaguly, E.; Crastiu, I.; Bereteu, L.

    2018-01-01

    Whole body vibrations have become a very popular method in recent years, both in physical therapy and in sports. This popularity is due to the fact that, as a result of analyzing the groups of subjects, the effects of small amplitude vibration and low frequency vibration, it was found an increase in the force developed by the feet, a hardening of bone strength or an increase in bone density. In this paper we propose to give a possible explanation of the stress relieving in muscle and/or bone after whole body vibration treatment. To do this we consider some rheological models which after whole body vibrations and after the analysis of their response lead to various experiments.

  11. Whole body vibration improves body mass, flexibility and strength in ...

    African Journals Online (AJOL)

    Objectives. This study aimed to determine the effectiveness of whole body vibration (WBV) training for promoting healthrelated physical fitness in sedentary adults. Design. A non-randomised sampling technique was used with an equivalent match-pair comparison group, pre- and posttest design. Volunteers were gathered ...

  12. Measurements of whole-body radioactivity in the UK population

    International Nuclear Information System (INIS)

    Fenwick, J.D.; Boddy, K.; McKenzie, A.L.; Oxby, C.B.

    1992-01-01

    A national survey of whole-body radioactivity was undertaken. A mobile whole-body counter visited collaborating Medical Physics Departments and Hospitals in England and Wales. Data were also obtained from an installed whole-body counter at the West Cumberland Hospital, Whitehaven, and from a control site at Addenbrooke's Hospital, Cambridge. 1657 volunteer members of the public were measured, including 162 children. 36% of volunteers had been measured in a similar survey 2 years earlier, and showed between a two and five fold reduction in body radiocaesium. No radiocaesium was detected in 54% of people measured. Measurements showed a progressive fall over the course of the study, reaching a baseline of 0.3 Bq 137 Cs/gK. In 1989, the additional radiation dose incurred from radiocaesium varied from a maximum of 4.1 μSv in Cumbria to 1.5 μSv in the South East, compared with the average annual radiation dose of 2500 μSv due to all other causes. No other gamma-emitting radionuclides were found. Results are consistent with Chernobyl as the source of the radiocaesium detected. (author)

  13. Effect of acute and delayed hyperbaric oxygen therapy on cyanide whole blood levels during acute cyanide intoxication

    DEFF Research Database (Denmark)

    Lawson-Smith, P; Jansen, E C; Hilsted, Linda Maria

    2011-01-01

    and the subsequent formation of cyanocobalamin measured by a spectrophotometer. Results showed that whole-blood-cyanide concentration in Group 1 controls and acute HBO2 initially rose and then fell towards zero. In rats treated with delayed HBO2, the reduction in whole-blood-cyanide concentration was significantly...

  14. Oak Ridge National Laboratory whole-body counter: internal operating procedure manual

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.

    1982-08-01

    The general purpose of the ORNL Whole Body Counter is to provide a rapid estimation of the type and quantity of radionuclide deposited in the human body. This report contains a review of the equipment in use at the facility and the procedure for its operation, the standard procedure for performing a routine whole body count, and a discussion of interpretation of results

  15. Whole-body cortisol response of zebrafish to acute net handling stress

    Science.gov (United States)

    Ramsay, J.M.; Feist, G.W.; Varga, Z.M.; Westerfield, M.; Kent, M.L.; Schreck, C.B.

    2009-01-01

    Zebrafish, Danio rerio, are frequently handled during husbandry and experimental procedures in the laboratory, yet little is known about the physiological responses to such stressors. We measured the whole-body cortisol levels of adult zebrafish subjected to net stress and air exposure at intervals over a 24 h period; cortisol recovered to near control levels by about 1 h post-net-stress (PNS). We then measured cortisol at frequent intervals over a 1 h period. Cortisol levels were more than 2-fold higher in net stressed fish at 3 min PNS and continued to increase peaking at 15 min PNS, when cortisol levels were 6-fold greater than the control cortisol. Mean cortisol declined from 15 to 60 min PNS, and at 60 min, net-stressed cortisol was similar to control cortisol. Because the age of fish differed between studies, we examined resting cortisol levels of fish of different ages (3, 7, 13, and 19 months). The resting cortisol values among tanks with the same age fish differed significantly but there was no clear effect of age. Our study is the first to report the response and recovery of cortisol after net handling for laboratory-reared zebrafish. ?? 2009 Elsevier B.V.

  16. Standardization of calibration method of whole-body counter. 1. Calibration by using anthropometric phantoms

    International Nuclear Information System (INIS)

    Ishikawa, Tetsuo; Matsumoto, Masaki; Uchiyama, Masafumi; Kobayashi, Sadayoshi; Mizushita, Seiichi.

    1995-01-01

    To standardize the calibration methods of whole-body counters, three anthropometric phantoms were manufactured based on dozens of Japanese average value of body size data. Using these phantoms, the calibrations of some whole-body counters were carried out and the comparison of counting efficiency between anthropometric phantoms and block phantoms, which used to be used for the calibration of whole-body counters generally, was implemented. Five whole-body counters, one scanning system, two stationary systems and two chair systems, were used for this study. The following results were derived: As an example, in NIRS scanning system, the counting efficiency of anthropometric phantom of 162cm height was 12.7% greater than that of block phantom of the same height. This means 137 Cs body burdens in adult men used to be estimated with the excess of about 10%. Body burdens tended to be estimated excessively in adult because the difference of counting efficiency between anthropometric phantom and block phantom increases with increase of height. To standardize body burden data measured with various whole-body counters, the calibration of each whole-body counter should be conducted using anthropometric phantoms and phantoms which used to be used for the calibration of that whole-body counter. (author)

  17. Whole-body counting of Fukushima residents after the TEPCO Fukushima Daiichi Nuclear Power Station accident

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Takumaro; Takada, Chie; Nakagawa, Takahiro; Nakai, Katsuta; Kurihara, Osamu; Tsujimura, Norio; Furuta, Sadaaki [Japan Atomic Energy Agency, Nuclear Fuel Cycle Engineering Laboratories, Tokai, Ibaraki (Japan); Ohi, Yoshihiro; Murayama, Takashi; Suzuki, Takashi [Japan Atomic Energy Agency, Nuclear Science Research Institute, Tokai, Ibaraki (Japan); Uezu, Yasuhiro [Japan Atomic Energy Agency, Fukushima Environmental Safety Center, Fukushima, Fukushima (Japan)

    2012-11-15

    At the request of the Fukushima government, the Japan Atomic Energy Agency (JAEA) started whole-body counting of residents on July 11, 2011, to assess radiation exposure after the TEPCO Fukushima Daiichi Nuclear Power Station accident. JAEA has examined residents in Iitate, Kawamata, Namie, and eight other local communities. The measurement capacity of the whole-body counting device is approximately 100 persons per day, and the total number of people to measure reached 9,927 by the end of January 2012. Two types of whole-body counter (WBC), each of which has two large-sized NaI(Tl) detectors, were used to perform the measurements. Physical phantoms (a Canberra RMC-II transfer phantom or a water-filled block phantom developed by JAEA) were used to perform the efficiency calibration of the WBCs, and results of this calibration were verified by comparing them with different-sized BOttle Mannequin ABsorber (BOMAB) phantoms imitating an adult male, a 10-year-old child, and a 4-year-old child. Short half-life radionuclides (e.g., {sup 131}I) originating from the accident were not detected in the present work, because the measurements were made starting four months after the accident. These measurements showed that about 80% of the residents were below a minimum detectable amount (MDA) of the measured radionuclides in the whole-body content. No artificial nuclides other than {sup 134}Cs and {sup 137}Cs were detected in the present whole-body counting. The maximum whole-body content of radiocesium ({sup 134}Cs and {sup 137}Cs in total) was 2.7 kBq for children (< 8 years old) and 14 kBq for adults. The radioactivity ratio ({sup 137}Cs/{sup 134}Cs) was estimated to be from 1.12 to 1.26. An acute intake scenario via inhalation of radiocesium was assumed in the present dose estimation for all the residents who were measured by the end of January 2012. The committed effective dose (CED) to 99.8% of the residents was found to be below 1 mSv. There were only 25 subjects with a

  18. Mosquito bite anaphylaxis: immunotherapy with whole body extracts.

    Science.gov (United States)

    McCormack, D R; Salata, K F; Hershey, J N; Carpenter, G B; Engler, R J

    1995-01-01

    Adverse reactions to mosquito bites have been recognized for some time. These usually consist of large local swellings and redness, generalized urticaria, angioedema and less easily definable responses such as nausea, dizziness, headaches, and lethargy. We report two patients who experienced systemic anaphylaxis from mosquito bites. Both were skin tested and given immunotherapy using whole body mosquito extracts. Skin testing using whole body mosquito extracts was positive to Aedes aegypti at 1/1,000 weight/volume (wt/vol) in one patient and to Aedes aegypti at 1/100,000 wt/vol, and Culex pipiens at 1/10,000 wt/vol in the other. Skin testing of ten volunteers without a history of adverse reactions to mosquito bites was negative. Immunotherapy using these extracts resulted in resolution of adverse reactions to mosquito bites in one patient and a decrease in reactions in the other. Immunotherapy with whole body mosquito extracts is a viable treatment option that can play a role in patients with mosquito bite-induced anaphylaxis. It may also result in severe side effects and one must determine the benefit versus risks for each individual patient.

  19. Whole-body magnetic resonance imaging in children: state of the art

    Directory of Open Access Journals (Sweden)

    Sara Reis Teixeira

    2015-04-01

    Full Text Available Whole-body imaging in children was classically performed with radiography, positron-emission tomography, either combined or not with computed tomography, the latter with the disadvantage of exposure to ionizing radiation. Whole-body magnetic resonance imaging (MRI, in association with the recently developed metabolic and functional techniques such as diffusion-weighted imaging, has brought the advantage of a comprehensive evaluation of pediatric patients without the risks inherent to ionizing radiation usually present in other conventional imaging methods. It is a rapid and sensitive method, particularly in pediatrics, for detecting and monitoring multifocal lesions in the body as a whole. In pediatrics, it is utilized for both oncologic and non-oncologic indications such as screening and diagnosis of tumors in patients with genetic syndromes, evaluation of disease extent and staging, evaluation of therapeutic response and post-therapy follow-up, evaluation of non neoplastic diseases such as multifocal osteomyelitis, vascular malformations and syndromes affecting multiple regions of the body. The present review was aimed at describing the major indications of whole-body MRI in pediatrics added of technical considerations.

  20. Evidence of impaired learning during whole-body vibration

    Science.gov (United States)

    Sherwood, N.; Griffin, M. J.

    1992-01-01

    A study of the effects of whole-body vibration on learning and memory was conducted, in which a context-dependent experimental design was used. Forty subjects completed a simple associative learning task, half during exposure to 16 Hz whole-body sinusoidal vertical vibration at 2.0 m s -2 r.m.s. and half while static. The results show that the rates of learning of the two groups differed, with that of the vibrated subjects significantly impaired. A second session, one week later, indicated that information learnt in one vibration environment could be recalled equally well in a different environment, suggesting no context-dependent effects on memory processes.

  1. A finite-element simulation of galvanic coupling intra-body communication based on the whole human body.

    Science.gov (United States)

    Song, Yong; Zhang, Kai; Hao, Qun; Hu, Lanxin; Wang, Jingwen; Shang, Fuzhou

    2012-10-09

    Simulation based on the finite-element (FE) method plays an important role in the investigation of intra-body communication (IBC). In this paper, a finite-element model of the whole body model used for the IBC simulation is proposed and verified, while the FE simulation of the galvanic coupling IBC with different signal transmission paths has been achieved. Firstly, a novel finite-element method for modeling the whole human body is proposed, and a FE model of the whole human body used for IBC simulation was developed. Secondly, the simulations of the galvanic coupling IBC with the different signal transmission paths were implemented. Finally, the feasibility of the proposed method was verified by using in vivo measurements within the frequency range of 10 kHz-5 MHz, whereby some important conclusions were deduced. Our results indicate that the proposed method will offer significant advantages in the investigation of the galvanic coupling intra-body communication.

  2. Human whole body cold adaptation.

    OpenAIRE

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    ABSTRACT Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000?y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations...

  3. Measurement of body potassium with a whole-body counter: relationship between lean body mass and resting energy expenditure

    International Nuclear Information System (INIS)

    Jensen, M.D.; Braun, J.S.; Vetter, R.J.; Marsh, H.M.

    1988-01-01

    We conducted studies to determine whether the Mayo whole-body counter could be used to measure body potassium, and thus lean body mass (LBM), and whether moderate obesity alters resting energy expenditure when corrected for LBM. Twenty-four nonobese and 18 moderately obese adults underwent body potassium (40K) counting, as well as tritiated water space measurement and indirect calorimetry. LBM values predicted from 40K counting and tritiated water space measurements were highly correlated (P = 0.001; r = 0.88). Resting energy expenditure was closely related to LBM (P less than 0.0001; r = 0.78): kcal/day = 622 kcal + (LBM.20.0 kcal/kg LBM). In this relationship, the obese subjects did not differ from nonobese subjects. In summary, the Mayo whole-body counter can accurately measure LBM, and moderate obesity has no detectable effect on corrected resting energy expenditure

  4. Rifaximin diminishes neutropenia following potentially lethal whole-body radiation.

    Science.gov (United States)

    Jahraus, Christopher D; Schemera, Bettina; Rynders, Patricia; Ramos, Melissa; Powell, Charles; Faircloth, John; Brawner, William R

    2010-07-01

    Terrorist attacks involving radiological or nuclear weapons are a substantial geopolitical concern, given that large populations could be exposed to potentially lethal doses of radiation. Because of this, evaluating potential countermeasures against radiation-induced mortality is critical. Gut microflora are the most common source of systemic infection following exposure to lethal doses of whole-body radiation, suggesting that prophylactic antibiotic therapy may reduce mortality after radiation exposure. The chemical stability, easy administration and favorable tolerability profile of the non-systemic antibiotic, rifaximin, make it an ideal potential candidate for use as a countermeasure. This study evaluated the use of rifaximin as a countermeasure against low-to-intermediate-dose whole-body radiation in rodents. Female Wistar rats (8 weeks old) were irradiated with 550 cGy to the whole body and were evaluated for 30 d. Animals received methylcellulose, neomycin (179 mg/kg/d) or variably dosed rifaximin (150-2000 mg/kg/d) one hour after irradiation and daily throughout the study period. Clinical assessments (e.g. body weight) were made daily. On postirradiation day 30, blood samples were collected and a complete blood cell count was performed. Animals receiving high doses of rifaximin (i.e. 1000 or 2000 mg/kg/d) had a greater increase in weight from the day of irradiation to postirradiation day 30 compared with animals that received placebo or neomycin. For animals with an increase in average body weight from irradiation day within 80-110% of the group average, methylcellulose rendered an absolute neutrophil count (ANC) of 211, neomycin rendered an ANC of 334, rifaximin 300 mg/kg/d rendered an ANC of 582 and rifaximin 1000 mg/kg/d rendered an ANC of 854 (P = 0.05 for group comparison). Exposure to rifaximin after near-lethal whole-body radiation resulted in diminished levels of neutropenia.

  5. Whole-Body MR Imaging Including Angiography: Predicting Recurrent Events in Diabetics.

    Science.gov (United States)

    Bertheau, Robert C; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M; Parhofer, Klaus G; Kauczor, Hans-Ulrich; Schoenberg, Stefan O; Weckbach, Sabine; Schlett, Christopher L

    2016-05-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30%) developed one, 8 (13%) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75%, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63%, p = 0.001), carotid artery stenosis (11/17/63%, p = 0.005), peripheral artery stenosis (26/56/88%, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. • Patients with long-standing diabetes mellitus are at high risk for recurrent events. • Whole-body MRI predicts occurrence of recurrent events independently of clinical characteristics. • The vessel score derived from whole-body angiography is a good general risk-marker. • Whole-body MRI may also provide organ-specific risk assessment. • Current findings may indicate benefits of

  6. Whole Body Magnetic Resonance Imaging in the Diagnosis of Parsonage Turner Syndrome

    International Nuclear Information System (INIS)

    Ryan, M.; Twair, A.; Nelson, E.; Brennan, D.; Eustace, S.

    2004-01-01

    Purpose: To describe magnetic resonance imaging (MRI) findings in patients with suspected Parsonage Turner syndrome and to emphasize the value of an additional whole body MR scan to improve specificity of this diagnosis. Material and Methods: Three patients with proven Parsonage Turner syndrome referred for conventional MRI of the shoulder girdle and additional whole body turboSTIR MRI were included for study. Results: In each case, imaging revealed edema in the muscles of the shoulder girdle. Whole body turboSTIR MRI scan confirmed localized unilateral changes in each case improving specificity and confidence in the diagnosis of Parsonage Turner syndrome in each case. Conclusion: Whole body turboSTIR MR imaging is a useful diagnostic tool in the evaluation of patients with suspected Parsonage Turner syndrome. Inclusion of the brain, neck, brachial plexus, and extremity musculature at whole body imaging allows differentiation from polymyositis and elimination of additional causes of shoulder girdle pain and weakness including gross lesions in the brain, neck, and brachial plexus by a single non-invasive study

  7. Whole-body MRI using a sliding table and repositioning surface coil approach

    International Nuclear Information System (INIS)

    Takahara, Taro; Kwee, Thomas; Luijten, Peter; Kibune, Satoshi; Ochiai, Reiji; Sakamoto, Tetsuro; Niwa, Tetsu; Van Cauteren, Marc

    2010-01-01

    To introduce and assess a new way of performing whole-body magnetic resonance imaging (MRI) using a non-integrated surface coil approach as available on most clinical MRI systems worldwide. Ten consecutive asymptomatic subjects prospectively underwent whole-body MRI for health screening. Whole-body MRI included T1-, T2- and diffusion-weighted sequences, and was performed using a non-integrated surface coil to image four different stations without patient repositioning. The four separately acquired stations were merged, creating seamless coronal whole-body T1-, T2- and diffusion-weighted images. Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations were qualitatively assessed. The average time (±SD) taken to change the surface coil from one station to the next station was 53.8 (±7.1) s. The average total extra examination time ± SD was 2 min 41.4 s (±15.3 s). Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations of T1-, T2- and diffusion-weighted whole-body MRI were overall graded as ''good'' to ''excellent''. This study shows that a time-efficient and high-quality whole-body MRI examination can easily be performed by using a non-integrated sliding surface coil approach. (orig.)

  8. Segmentation and visual analysis of whole-body mouse skeleton microSPECT

    NARCIS (Netherlands)

    Khmelinskii, A.; Groen, H.C.; De Jong, M.; Lelieveldt, B.P.F.

    2012-01-01

    Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality,

  9. Segmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT

    NARCIS (Netherlands)

    A. Khmelinskii (Artem); H.C. Groen (Harald); M. Baiker (Martin); M. de Jong (Marion); B.P.F. Lelieveldt (Boudewijn)

    2012-01-01

    textabstractWhole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput,

  10. Comparison of atlas-based techniques for whole-body bone segmentation

    DEFF Research Database (Denmark)

    Arabi, Hossein; Zaidi, Habib

    2017-01-01

    out in terms of estimating bone extraction accuracy from whole-body MRI using standard metrics, such as Dice similarity (DSC) and relative volume difference (RVD) considering bony structures obtained from intensity thresholding of the reference CT images as the ground truth. Considering the Dice....../MRI. To this end, a variety of atlas-based segmentation strategies commonly used in medical image segmentation and pseudo-CT generation were implemented and evaluated in terms of whole-body bone segmentation accuracy. Bone segmentation was performed on 23 whole-body CT/MR image pairs via leave-one-out cross...... validation procedure. The evaluated segmentation techniques include: (i) intensity averaging (IA), (ii) majority voting (MV), (iii) global and (iv) local (voxel-wise) weighting atlas fusion frameworks implemented utilizing normalized mutual information (NMI), normalized cross-correlation (NCC) and mean...

  11. [Modeling of processes of heat transfer in whole-body hyperthermia].

    Science.gov (United States)

    Kinsht, D N

    2006-01-01

    The method of whole-body hyperthermia in which the body temperature for a short time reaches values up to 43-44 degrees C holds currently much promise. However, at body temperatures above 42 degrees C, the risks associated with the hemodynamic instability and the appearance of arrhythmia in the patient increase. A model of heat transfer has been created to increase the efficiency and safety of the immersion-convectional method of whole-body hyperthermia. This model takes into account changes in the skin blood flow and the dynamics of pulse rate depending on body temperature. The model of heat transfer adequately reflects processes of heating of the organism and can form a basis for the calculation of distribution of heat inside the organism.

  12. Whole-body gene expression pattern registration in Platynereis larvae.

    Science.gov (United States)

    Asadulina, Albina; Panzera, Aurora; Verasztó, Csaba; Liebig, Christian; Jékely, Gáspár

    2012-12-03

    Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere) of the Platynereis trochophore larva and used for the detailed study of neuronal development. Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2'-thiodiethanol (TDE), which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP) in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4'6-diamidino-2-phenylindole (DAPI). Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental stage. We then registered to these templates the

  13. Whole-body gene expression pattern registration in Platynereis larvae

    Directory of Open Access Journals (Sweden)

    Asadulina Albina

    2012-12-01

    Full Text Available Abstract Background Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere of the Platynereis trochophore larva and used for the detailed study of neuronal development. Results Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2’-thiodiethanol (TDE, which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4’6-diamidino-2-phenylindole (DAPI. Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental

  14. Whole-Body CT Screening--Should I or Shouldn't I Get One?

    Science.gov (United States)

    ... Procedures Medical Imaging Medical X-ray Imaging Whole-Body CT Screening--Should I or shouldn't I ... What are the risks and benefits of whole-body CT screening? Many people believe incorrectly that a ...

  15. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1990-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV) ane....... This anesthetic technique and the stethoscope have been used in seven children. The total IV anesthesia proved to be a useful method for children during whole body radiation. The modified stethoscope functioned very well and was a useful complement to the monitoring equipment....

  16. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1991-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV) ane....... This anesthetic technique and the stethoscope have been used in seven children. The total IV anesthesia proved to be a useful method for children during whole body radiation. The modified stethoscope functioned very well and was a useful complement to the monitoring equipment....

  17. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  18. The effects of whole body vibration combined computerized postural control training on the lower extremity muscle activity and cerebral cortex activity in stroke patients.

    Science.gov (United States)

    Uhm, Yo-Han; Yang, Dae-Jung

    2018-02-01

    [Purpose] The purpose of this study was to examine the effect of computerized postural control training using whole body vibration on lower limb muscle activity and cerebral cortical activation in acute stroke patients. [Subjects and Methods] Thirty stroke patients participated and were divided into groups of 10, a group of the computerized postural control training using whole body vibration (Group I), the computerized postural control training combined with aero step (Group II) and computerized postural control training (Group III). MP100 was used to measure lower limb muscle activity, and QEEG-8 was used to measure cerebral cortical activation. [Results] Comparison of muscle activity and cerebral cortical activation before and after intervention between groups showed that Group I had significant differences in lower limb muscle activity and cerebral cortical activation compared to Groups II and III. [Conclusion] This study showed that whole body vibration combined computerized postural control training is effective for improving muscle activity and cerebral cortex activity in stroke patients.

  19. Natural β-carotene and whole body irradiation in rats

    International Nuclear Information System (INIS)

    Ben-Amotz, A.; Rachmilevich, B.; Greenberg, S.; Sela, M.; Weshler, Z.

    1996-01-01

    β-Carotene and other carotenoids are reported to be potent free radical quenchers, singlet oxygen scavengers, and lipid antioxidants. Whole-body irradiation is known to cause an immunosuppression effect in mammals through the possible initiation and production of reactive oxygen species. We decided to test the possible antioxidative effect against whole-body irradiation of a natural β-carotene, composed of equal amounts of the all-trans and 9-cis isomers, obtained from the unicellular alga Dunaliella bardawil. Rats were fed on ground commercial food enriched with natural β-carotene (50 mg/kg diet). On completion of 1 week with β-carotene, the rats were exposed to a single dose of 4 Gy whole-body irradiation, after which their livers and blood were removed for β-carotene and retinol analysis in comparison with control livers of animals irradiated or not, or supplemented with β-carotene after irradiation. A normal increase in body weight with no ill effects was noted in the groups of rats whose diet was supplemented by β-carotene before and after irradiation, compared with the reduction in the specific growth rate in the group of rats irradiated without β-carotene. Liver β-carotene and retinol decreased significantly after irradiation compared with the rats which were not irradiated. This decrease was not shown in rats fed β-carotene prior to irradiation, and the effect of irradiation was partially cured by supplementation with β-carotene after irradiation. High-pressure liquid chromatography (HPLC) analysis of the irradiated animals showed a selective decline in 9-cis β-carotene and in retinol over all-trans β-carotene and retinyl esters. These results suggest that 9-cis β-carotene and retinol protect in vivo against the cellular damage by free radicals induced after whole-body irradiation. (orig.). With 1 fig., 2 tabs

  20. Improved measurement system for the whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1983-01-01

    A static four-detector system has been established as a whole body radioactivity measurement system. A technique is being developed to position the detectors in such a manner as to minimise longitudinal distribution effects within a subject. This technique, which represents the human body as a simple geometric model, requires the determination of efficiency at any point within this model

  1. FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure

    International Nuclear Information System (INIS)

    Hirata, Akimasa; Asano, Takayuki; Fujiwara, Osamu

    2008-01-01

    The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 deg. C at a whole-body-averaged specific absorption rate of 0.08 W kg -1 , which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface area-to-mass ratio

  2. FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Akimasa; Asano, Takayuki; Fujiwara, Osamu [Department of Computer Science and Engineering, Nagoya Institute of Technology (Japan)], E-mail: ahirata@nitech.ac.jp

    2008-09-21

    The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 deg. C at a whole-body-averaged specific absorption rate of 0.08 W kg{sup -1}, which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface area-to-mass ratio.

  3. FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure.

    Science.gov (United States)

    Hirata, Akimasa; Asano, Takayuki; Fujiwara, Osamu

    2008-09-21

    The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 degrees C at a whole-body-averaged specific absorption rate of 0.08 W kg(-1), which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface area-to-mass ratio.

  4. Whole-body microvascular permeability of small molecules in man

    DEFF Research Database (Denmark)

    Henriksen, J H

    1985-01-01

    In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured by the indica......In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured...

  5. Whole body perfusion for hybrid aortic arch repair: evolution of selective regional perfusion with a modified extracorporeal circuit.

    Science.gov (United States)

    Fernandes, Philip; Walsh, Graham; Walsh, Stephanie; O'Neil, Michael; Gelinas, Jill; Chu, Michael W A

    2017-04-01

    Patients undergoing hybrid aortic arch reconstruction require careful protection of vital organs. We believe that whole body perfusion with tailored dual circuitry may help to achieve optimal patient outcomes. Our circuit has evolved from a secondary circuit utilizing a cardioplegia delivery device for lower body perfusion to a dual-oxygenator circuit. This allows individually controlled regional perfusion with ease of switching from secondary to primary circuit for total body flow. The re-design allows for separate flow and temperature regulation with two oxygenators in parallel. All patients underwent a single-stage operation for simultaneous treatment of arch and descending aortic pathology via a sternotomy, using a hybrid frozen elephant trunk technique. We report six consecutive patients undergoing hybrid arch and frozen elephant trunk reconstruction using a dual-oxygenator circuit. Five patients underwent elective surgery and one was emergent. One patient had an acute dissection while three underwent concomitant procedures, including a Ross procedure and two valve-sparing root reconstructions. Three cases were redo sternotomies. The mean pump time was 358 ± 131 min, the aortic cross clamp time 243 ± 135 min, the cardioplegia volume of 33,208 ml ± 16,173, cerebral ischemia 0 min, lower body ischemia 76 ± 34 min and the average lower body perfusion time was 142 min. Two patients did not require any donor blood products. The median intensive care unit (ICU) and hospital lengths of stay (LOS) were two days and 10 days, respectively. The average peak serum lactate on CPB was 7.47 mmol/L and, at admission to the ICU, it was 3.37 mmol/L. Renal and respiratory failure developed in the salvage acute type A dissection patient. No other complications occurred in this series. Whole body perfusion as delivered through individually controlled dual-oxygenator circuitry allows maximum flexibility for hybrid aortic arch reconstruction. A modified circuit perfusion

  6. Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI).

    LENUS (Irish Health Repository)

    Gleeson, T G

    2009-03-01

    The aim of the study is to assess the feasibility of whole-body low-dose computed tomography (WBLDCT) in the diagnosis and staging of multiple myeloma and compare to skeletal survey (SS), using bone marrow biopsy and whole-body magnetic resonance imaging (WBMRI; where available) as gold standard.

  7. Whole body detectors for clinical applications

    International Nuclear Information System (INIS)

    Silar, J.

    The requirements are presented on the parameters of whole-body detectors suitable for clinical retention assays and the detector-patient configuration described. A whole-body detector was developed with an axial configuration of two pairs of large-volume scintillation detectors with NaI(Tl) crystals. One pair is placed under the bed, the other above the bed on which the patient is being examined. The axes of the crystals are located at a distance of 90 cm apart. The field of vision of the detector is described for the application of a 137 Cs source in the air and in a 24 cm layer of water. The positive characteristics of the detector are listed as being homogeneous sensitivity, energy resolution, long-term stability of signal pulse amplitude and average pulse rate in the integral mode. The results obtained show that the detector may be used to evaluate the level of contamination of persons by gamma emitters within the region of approximately 800 Bq to 74 MBq. The error in converting the number of signal pulses in the integral mode does not exceed 50% for gamma emitters with a photon energy above 30O keV. (J.B.)

  8. Dynamics of human whole body amino acid metabolism

    International Nuclear Information System (INIS)

    Young, V.R.

    1981-01-01

    The mechanism of regulation of the nitrogen metabolism in humans under various nutritional and physiological states was examined using stable isotopes. In the simultaneous continuous infusion of 1- [ 13 ] - leucine and α- [ 15 N]- lysine, their fluxed decreased when individuals received lower protein intake. The rates of oxidation and incorporation into body proteins of leucine changed in parallel with the protein intake. Such effects of diet on whole body leucine kinetics were modified by the energy state and dietary energy level. The nitrogen balance was also improved by an excess level of dietary energy. When the intake of dietary protein was lowered below the maintenance level, the whole body flux and de novo synthesis of glycine were lowered, but alanine synthesis was clearly increased. The intravenous infusion of glucose at 4 mg/kg.min, which causes increase in excess blood sugar and plasma insulin, increased the alanine flux, but had no effect on the glycine flux. The rate of albumin synthesis, determined by giving 15 N-glycine orally every 3 hr, decreased with the lowered intake of dietary protein in young men, but not in elderly men. This explains why the serum albumin synthesis increases with the increase in the intake of dietary protein in young men, but not in elderly men. The rate of whole body protein synthesis in young men receiving the L-amino acid diets providing with the required intake of specific amino acid was much lower than that in the men receiving the diets providing with generous intake of specific amino acid. Thus the control mechanism to maintain the homeostasis of body nitrogen and amino acids is related in some unknown way to the nutritional requirement of the hosts. (Kaihara, S.)

  9. Use of extremity insulation during whole body hyperthermia to reduce temperature nonuniformity

    International Nuclear Information System (INIS)

    Thrall, D.E.; Page, R.L.

    1987-01-01

    The author previously documented during whole body hyperthermia in dogs using a radiant heating device that temperature at superficial sites, including tibial bone marrow, falls below systemic arterial temperature during the plateau phase of heating. This may be due to direct heat loss to the environment. Sites where temperature is lower than systemic arterial temperature during the plateau phase may become sanctuary sites where tumor deposits are spared because they do not receive the prescribed thermal dose. In an attempt to decrease temperature nonuniformity and increase thermal dose delivered to such superficial sites, extremity insulation has been employed during whole body hyperthermia in dogs. The author measured temperature at cutaneous and subcutaneous sites and within tibial bone marrow in insulated and noninsulated extremities of dogs undergoing whole body hyperthermia in the radiant heating device. The author found that extremity insulation is effective in reducing extremity temperature nonuniformity. Specific results are presented. Extremity insulation may be necessary during whole body hyperthermia to assure that extremity tumor deposits receive a thermal dose similar to that prescribed for the entire body

  10. A high protein diet upregulated whole-body protein turnover during energy deficit

    Science.gov (United States)

    The effects of higher protein diets and sustained energy deficit (ED) on whole-body protein turnover (WBPTO) are not well described. This study examined whether dietary protein level influences whole-body protein breakdown (Ra), non-oxidative leucine disposal (NOLD), and oxidation (Ox) during ED. ...

  11. Whole-grain pasta reduces appetite and meal-induced thermogenesis acutely

    DEFF Research Database (Denmark)

    Cioffi, Iolanda; Santarpia, Lidia; Vaccaro, Andrea

    2016-01-01

    In epidemiological studies, the intake of foods rich in dietary fiber is associated with a reduced risk of developing overweight and type 2 diabetes. This work aims to identify acute strategies to regulate appetite and improve glucose control by using different pasta meals. Hence, 4 different...... isocaloric lunch meals, consisting of (i) refined-grain pasta (RG+T), (ii) whole-grain pasta (WG+T), (iii) lemon juice-supplemented refined-grain pasta (LRG+T), and (iv) refined-grain pasta with legumes (RG+L), were administered to 8 healthy participants in a crossover design. On the test days, participants...... glucose (p = 0.001) was lower for RG+T, and triacylglycerols (p = 0.02) increased for LRG+T; however, insulin, C-peptide, and ghrelin were comparable in all other meals. In conclusion, our study indicates that acute consumption of whole-grain pasta may promote fullness and reduce hunger, lowering...

  12. A case of acute exacerbation of idiopathic pulmonary fibrosis after proton beam therapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Nagano, Tatsuya; Kotani, Yoshikazu; Fujii, Osamu

    2012-01-01

    There have been no reports describing acute exacerbations of idiopathic pulmonary fibrosis after particle radiotherapy for non-small cell lung cancer. The present study describes the case of a 76-year-old Japanese man with squamous cell carcinoma of the lung that relapsed in the left upper lobe 1 year after right upper lobectomy. He had been treated with oral prednisolone 20 mg/day every 2 days for idiopathic pulmonary fibrosis, and the relapsed lung cancer was treated by proton beam therapy, which was expected to cause the least adverse effects on the idiopathic pulmonary fibrosis. Fifteen days after the initiation of proton beam therapy, the idiopathic pulmonary fibrosis exacerbated, centered on the left upper lobe, for which intensive steroid therapy was given. About 3 months later, the acute exacerbation of idiopathic pulmonary fibrosis had improved, and the relapsed lung cancer became undetectable. Clinicians should be aware that an acute exacerbation of idiopathic pulmonary fibrosis may occur even in proton beam therapy, although proton beam therapy appears to be an effective treatment option for patients with idiopathic pulmonary fibrosis. (author)

  13. Late response to whole-lung irradiation alone and with whole-body hyperthermia in dogs

    International Nuclear Information System (INIS)

    Gillette, S.M.; Gillette, E.L.; Dawson, C.A.

    1997-01-01

    The late effects of whole-lung irradiation with and without whole-body hyperthermia were studied in beagle dogs. The reference doses ranged from 18 to 49.5 Gy given in 1.5-Gy fractions over 6 weeks. Whole-body hyperthermia was given in three 2-h treatments to a deep rectal temperature of 42.0 degrees C. Radiation was given simultaneously with hyperthermia on those days. Physiological and histopathological responses were evaluated. Physiological changes included decreases in cardiac output, systemic blood pressure, dynamic compliance and serotonin uptake. Early changes included an increase in extravascular water and total protein in the lavage. These changes were considered mild, were compensated for and occurred only in dogs receiving doses of 40.5 Gy or greater given in 1.5-Gy fractions over 6 weeks. Histopathological change were typical of irradiated lung and included pleural fibrosis, interstitial fibrosis, fibrotic foci, and peribronchial and perivascular fibrosis. There was no enhancement of late injury to lung by hyperthermia seen in this study. 17 refs., 3 figs., 2 tabs

  14. Made-to-measure pattern development based on 3D whole body scans

    NARCIS (Netherlands)

    Daanen, H.; Hong, S.A.

    2008-01-01

    Purpose - New techniques are required to link 3D whole body scans to manufacturing techniques to allow for the mass-customization of clothes. This study aims to compare two methods of producing skirts based on 3D whole body scans. Design/methodology/approach - Three females participated in the

  15. Signal Processing Methods for Removing the Effects of Whole Body Vibration upon Speech

    Science.gov (United States)

    Bitner, Rachel M.; Begault, Durand R.

    2014-01-01

    Humans may be exposed to whole-body vibration in environments where clear speech communications are crucial, particularly during the launch phases of space flight and in high-performance aircraft. Prior research has shown that high levels of vibration cause a decrease in speech intelligibility. However, the effects of whole-body vibration upon speech are not well understood, and no attempt has been made to restore speech distorted by whole-body vibration. In this paper, a model for speech under whole-body vibration is proposed and a method to remove its effect is described. The method described reduces the perceptual effects of vibration, yields higher ASR accuracy scores, and may significantly improve intelligibility. Possible applications include incorporation within communication systems to improve radio-communication systems in environments such a spaceflight, aviation, or off-road vehicle operations.

  16. Whole-body imaging of the musculoskeletal system: the value of MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Gerwin P.; Reiser, Maximilian F.; Baur-Melnyk, Andrea [University Hospitals Munich/Grosshadern, LMU, Institute of Clinical Radiology, Munich (Germany)

    2007-12-15

    In clinical practice various modalities are used for whole-body imaging of the musculoskeletal system, including radiography, bone scintigraphy, computed tomography, magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET-CT). Multislice CT is far more sensitive than radiographs in the assessment of trabecular and cortical bone destruction and allows for evaluation of fracture risk. The introduction of combined PET-CT scanners has markedly increased diagnostic accuracy for the detection of skeletal metastases compared with PET alone. The unique soft-tissue contrast of MRI enables for precise assessment of bone marrow infiltration and adjacent soft tissue structures so that alterations within the bone marrow may be detected before osseous destruction becomes apparent in CT or metabolic changes occur on bone scintigraphy or PET scan. Improvements in hard- and software, including parallel image acquisition acceleration, have made high resolution whole-body MRI clinically feasible. Whole-body MRI has successfully been applied for bone marrow screening of metastasis and systemic primary bone malignancies, like multiple myeloma. Furthermore, it has recently been proposed for the assessment of systemic bone diseases predisposing for malignancy (e.g., multiple cartilaginous exostoses) and muscle disease (e.g., muscle dystrophy). The following article gives an overview on state-of-the-art whole-body imaging of the musculoskeletal system and highlights present and potential future applications, especially in the field of whole-body MRI. (orig.)

  17. Application of Whole Body Counter to Neutron Dose Assessment in Criticality Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, O.; Tsujimura, N.; Takasaki, K.; Momose, T.; Maruo, Y. [Japan Nuclear Cycle Development Institute, Tokai (Japan)

    2001-09-15

    Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of {sup 24}Na in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of {sup 24}Na is approximately 50Bq for 10minute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 [(Bq{sup 24}Na/g{sup 23}Na)/mGy].

  18. Detection of bone metastasis of prostate cancer. Comparison of whole-body MRI and bone scintigraphy

    International Nuclear Information System (INIS)

    Ketelsen, D.; Roethke, M.; Aschoff, P.; Lichy, M.P.; Claussen, C.D.; Schlemmer, H.P.; Merseburger, A.S.; Reimold, M.

    2008-01-01

    Purpose: prostate cancer continues to be the third leading cancer-related mortality of western men. Early diagnosis of bone metastasis is important for the therapy regime and for assessing the prognosis. The standard method is bone scintigraphy. Whole-body MRI proved to be more sensitive for early detection of skeletal metastasis. However, studies of homogenous tumor entities are not available. The aim of the study was to compare bone scintigraphy and whole-body MRI regarding the detection of bone metastasis of prostate cancer. Materials and methods: 14 patients with histologically confirmed prostate cancer and a bone scintigraphy as well as whole-body MRI within one month were included. The mean age was 68 years. Scintigraphy was performed using the planar whole-body technique (ventral and dorsal projections). Suspect areas were enlarged. Whole-body MRI was conducted using native T1w and STIR sequences in the coronary plane of the whole body, sagittal imaging of spine and breath-hold STIR and T1w-Flash-2D sequences of ribs and chest. Bone scintigraphy and whole-body MRI were evaluated retrospectively by experienced radiologists in a consensus reading on a lesion-based level. Results: whole-body MRI detected significantly more bone metastasis (p = 0.024). 96.4% of the demonstrated skeletal metastases in bone scintigraphy were founded in whole-body MRI while only 58.6% of the depicted metastases in MRI were able to be located in scintigraphy. There was no significant difference regarding bone metastasis greater than one centimeter (p = 0.082) in contrast to metastasis less than one centimeter (p = 0.035). Small osteoblastic metastases showed a considerably higher contrast in T1w sequences than in STIR imaging. Further advantages of whole-body MRI were additional information about extra-osseous tumor infiltration and their complications, for example stenosis of spinal canal or vertebral body fractures, found in 42.9% of patients. (orig.)

  19. A Single Day of Excessive Dietary Fat Intake Reduces Whole-Body Insulin Sensitivity: The Metabolic Consequence of Binge Eating

    Directory of Open Access Journals (Sweden)

    Siôn A. Parry

    2017-07-01

    Full Text Available Consuming excessive amounts of energy as dietary fat for several days or weeks can impair glycemic control and reduce insulin sensitivity in healthy adults. However, individuals who demonstrate binge eating behavior overconsume for much shorter periods of time; the metabolic consequences of such behavior remain unknown. The aim of this study was to determine the effect of a single day of high-fat overfeeding on whole-body insulin sensitivity. Fifteen young, healthy adults underwent an oral glucose tolerance test before and after consuming a high-fat (68% of total energy, high-energy (78% greater than daily requirements diet for one day. Fasting and postprandial plasma concentrations of glucose, insulin, non-esterified fatty acids, and triglyceride were measured and the Matsuda insulin sensitivity index was calculated. One day of high-fat overfeeding increased postprandial glucose area under the curve (AUC by 17.1% (p < 0.0001 and insulin AUC by 16.4% (p = 0.007. Whole-body insulin sensitivity decreased by 28% (p = 0.001. In conclusion, a single day of high-fat, overfeeding impaired whole-body insulin sensitivity in young, healthy adults. This highlights the rapidity with which excessive consumption of calories through high-fat food can impair glucose metabolism, and suggests that acute binge eating may have immediate metabolic health consequences for the individual.

  20. Direct molecular analysis of whole-body animal tissue sections by MALDI imaging mass spectrometry.

    Science.gov (United States)

    Reyzer, Michelle L; Chaurand, Pierre; Angel, Peggi M; Caprioli, Richard M

    2010-01-01

    The determination of the localization of various compounds in a whole animal is valuable for many applications, including pharmaceutical absorption, distribution, metabolism, and excretion (ADME) studies and biomarker discovery. Imaging mass spectrometry is a powerful tool for localizing compounds of biological interest with molecular specificity and relatively high resolution. Utilizing imaging mass spectrometry for whole-body animal sections offers considerable analytical advantages compared to traditional methods, such as whole-body autoradiography, but the experiment is not straightforward. This chapter addresses the advantages and unique challenges that the application of imaging mass spectrometry to whole-body animal sections entails, including discussions of sample preparation, matrix application, signal normalization, and image generation. Lipid and protein images obtained from whole-body tissue sections of mouse pups are presented along with detailed protocols for the experiments.

  1. 2nd Tuebingen radiotherapy symposium: Whole body, large field and whole skin irradiation. Introduction

    International Nuclear Information System (INIS)

    Huebener, K.H.; Frommhold, W.

    1987-01-01

    The symposium which took place on the 11th and 12th April 1986 set itself the task of discussing three different groups of radiotherapy topics. The chief issue was whole-body irradiation prior to bone marrow transplants, in which all the therapy centres in West Germany, Austria, East Germany and German-speaking Switzerland made clinical and radiophysical contributions. The second part of the Symposium consisted mainly of talks and discussions on large-field irradiation, more precisely half-body and sequential partial body irradiation. This topic was chosen because this type of therapy is scarcely practised at all, particularly in West Germany, whereas in the United States, East Germany, Switzerland and a number of other countries it has long since become one of the established methods. The last talk at the Symposium explained clinical and radiophysical aspects of whole-skin irradiation. Here too, one was impressed by the wide diversity of the equipment and methods of irradiation used which, nevertheless, all demonstrated satisfactory practical solutions in their common aim of distributing the dose as homogeneously as possible. (orig./MG) [de

  2. Statistical multi-path exposure method for assessing the whole-body SAR in a heterogeneous human body model in a realistic environment.

    Science.gov (United States)

    Vermeeren, Günter; Joseph, Wout; Martens, Luc

    2013-04-01

    Assessing the whole-body absorption in a human in a realistic environment requires a statistical approach covering all possible exposure situations. This article describes the development of a statistical multi-path exposure method for heterogeneous realistic human body models. The method is applied for the 6-year-old Virtual Family boy (VFB) exposed to the GSM downlink at 950 MHz. It is shown that the whole-body SAR does not differ significantly over the different environments at an operating frequency of 950 MHz. Furthermore, the whole-body SAR in the VFB for multi-path exposure exceeds the whole-body SAR for worst-case single-incident plane wave exposure by 3.6%. Moreover, the ICNIRP reference levels are not conservative with the basic restrictions in 0.3% of the exposure samples for the VFB at the GSM downlink of 950 MHz. The homogeneous spheroid with the dielectric properties of the head suggested by the IEC underestimates the absorption compared to realistic human body models. Moreover, the variation in the whole-body SAR for realistic human body models is larger than for homogeneous spheroid models. This is mainly due to the heterogeneity of the tissues and the irregular shape of the realistic human body model compared to homogeneous spheroid human body models. Copyright © 2012 Wiley Periodicals, Inc.

  3. Short Duration Small Sided Football and to a Lesser Extent Whole Body Vibration Exercise Induce Acute Changes in Markers of Bone Turnover

    Directory of Open Access Journals (Sweden)

    J. L. Bowtell

    2016-01-01

    Full Text Available We aimed to study whether short-duration vibration exercise or football sessions of two different durations acutely changed plasma markers of bone turnover and muscle strain. Inactive premenopausal women (n=56 were randomized to complete a single bout of short (FG15 or long duration (FG60 small sided football or low magnitude whole body vibration training (VIB. Procollagen type 1 amino-terminal propeptide (P1NP was increased during exercise for FG15 (51.6±23.0 to 56.5±22.5 μg·L−1, mean ± SD, P0.05. An increase in osteocalcin was observed 48 h after exercise (P<0.05, which did not differ between exercise groups. C-terminal telopeptide of type 1 collagen was not affected by exercise. Blood lactate concentration increased during exercise for FG15 (0.6±0.2 to 3.4±1.2 mM and FG60 (0.6±0.2 to 3.3±2.0 mM, but not for VIB (0.6±0.2 to 0.8±0.4 mM (P<0.05. Plasma creatine kinase increased by 55±63% and 137±119% 48 h after FG15 and FG60 (P<0.05, but not after VIB (26±54%, NS. In contrast to the minor elevation in osteocalcin in response to a single session of vibration exercise, both short and longer durations of small sided football acutely increased plasma P1NP, osteocalcin, and creatine kinase. This may contribute to favorable effects of chronic training on musculoskeletal health.

  4. Chromosomal aberrations in Cynomolgus peripheral lymphocytes during and after fractionated whole-body γ-irradiation

    International Nuclear Information System (INIS)

    Guedeney, G.; Malarbet, J.L.; Doloy, M.T.

    1989-01-01

    Cynomolgus monkeys (Macaca fascicularis) were exposed to fractionated whole-body γ-irradiation at high and low dose rates for 4 or 5 weeks. The time-dependence of chromosomal aberrations was studied in relation to the number of lymphocytes during irradiation and after exposure for periods of up to about 600 days for chromosomal aberrations and 200 days for lymphocyte counts. Additivity of the daily effects on the number of chromosomal aberrations was observed during the exposures. Immediately after the end of the exposures the number of chromosomal aberrations decreased to reach low values. The disappearance of chromosomal aberrations seemed to be related to recovery of the lymphocyte counts. The data presented here emphasize the different kinetic patterns of chromosomal aberrations after fractionated and acute irradiation. (author)

  5. Admission body temperature predicts long-term mortality after acute stroke

    DEFF Research Database (Denmark)

    Kammersgaard, L P; Jørgensen, H S; Rungby, Jørgen

    2002-01-01

    Body temperature is considered crucial in the management of acute stroke patients. Recently hypothermia applied as a therapy for stroke has been demonstrated to be feasible and safe in acute stroke patients. In the present study, we investigated the predictive role of admission body temperature...

  6. Effects of quadriceps strength after static and dynamic whole-body vibration exercise.

    Science.gov (United States)

    Bush, Jill A; Blog, Gabriel L; Kang, Jie; Faigenbaum, Avery D; Ratamess, Nicholas A

    2015-05-01

    Numerous studies have shown performance benefits including whole-body vibration (WBV) as a training modality or an acute exercise protocol when used as a component of the resistance training program. Some studies have indicated that performing dynamic exercises as compared with static position exercises while exposed to WBV might be beneficial; however, evidence is lacking. Thus, the purpose of this study was to determine if an acute bout of dynamic versus static squats performed during WBV results in increase in quadriceps force production by means of dynamic isokinetic knee extension and flexion exercise. Nonresistance-trained healthy young men and women (N = 21) of 18-25 years participated in 4 protocols with 2-week rest in-between. Protocol 1 consisted of 5 sets of 10 dynamic squats without vibration; Protocol 2: 5 sets of 30-second static squats without vibration; Protocol 3: 5 sets of 10 dynamic squats with 30-Hz WBV for a total of 2.5 minutes; and Protocol 4: 5 sets of 30-second static squats with 30-Hz WBV for a total of 2.5 minutes. Prestrength tests (1 set of 4 repetitions at 100° · s(-1) for the knee extension exercise) was performed within 5 minutes of starting each protocol, and poststrength testing was performed within 1 minute of completing each protocol. Strength outcomes were analyzed by repeated measures analysis of variance with a significance level set at p ≤ 0.05. A significant decrease in strength was observed after dynamic and static squats without WBV (p = 0.002); an increase in strength after dynamic squats with WBV (p = 0.003); and a decrease in strength after static squats with WBV (p = 0.003). The inclusion of WBV to dynamic resistance exercise can be an added modality to increase strength. Whole-body vibration can have varied effects in altering muscle strength in untrained individuals according to the type of resistance training performed. As a dynamic squat with WBV seems to immediately potentiate neuromuscular functioning, the

  7. Whole-body vibration exercise in postmenopausal osteoporosis

    Directory of Open Access Journals (Sweden)

    Magdalena Weber-Rajek

    2015-01-01

    Full Text Available The report of the World Health Organization (WHO of 2008 defines osteoporosis as a disease characterized by low bone mass and an increased risk of fracture. Postmenopausal osteoporosis is connected to the decrease in estrogens concentration as a result of malfunction of endocrine ovarian function. Low estrogens concentration causes increase in bone demineralization and results in osteoporosis. Physical activity, as a component of therapy of patients with osteoporosis, has been used for a long time now. One of the forms of safe physical activity is the vibration training. Training is to maintain a static position or execution of specific exercises involving the appropriate muscles on a vibrating platform, the mechanical vibrations are transmitted to the body of the patient. According to the piezoelectric theory, pressure induces bone formation in the electrical potential difference, which acts as a stimulant of the process of bone formation. Whole body vibration increases the level of growth hormone and testosterone in serum, preventing sarcopenia and osteoporosis. The aim of this study was to review the literature on vibration exercise in patients with postmenopausal osteoporosis based on the PubMed and Medline database. While searching the database, the following key words were used ‘postmenopausal osteoporosis’ and ‘whole-body vibration exercise’.

  8. Transcranial magnetic stimulation probes the excitability of the primary motor cortex: A framework to account for the facilitating effects of acute whole-body exercise on motor processes

    Directory of Open Access Journals (Sweden)

    Karen Davranche

    2015-03-01

    Full Text Available The effects of exercise on decision-making performance have been studied using a wide variety of cognitive tasks and exercise interventions. Although the current literature supports a beneficial influence of acute exercise on cognitive performance, the mechanisms underlying this phenomenon have not yet been elucidated. We review studies that used single-pulse transcranial magnetic stimulation (TMS to probe the excitability of motor structures during whole-body exercise and present a framework to account for the facilitating effects of acute exercise on motor processes. Recent results suggest that, even in the absence of fatigue, the increase in corticospinal excitability classically reported during submaximal and exhausting exercises may be accompanied by a reduction in intracortical inhibition. We propose that reduced intracortical inhibition elicits an adaptive central mechanism that counteracts the progressive reduction in muscle responsiveness caused by peripheral fatigue. Such a reduction would render the motor cortex more sensitive to upstream influences, thus causing increased corticospinal excitability. Furthermore, reduction of intracortical inhibition may account for the more efficient descending drive and for the improvement of reaction time performance during exercise. The adaptive modulation in intracortical inhibition could be implemented through a general increase in reticular activation that would further account for enhanced sensory sensitivity.

  9. Prolonged bed rest decreases skeletal muscle and whole body protein synthesis

    Science.gov (United States)

    Ferrando, A. A.; Lane, H. W.; Stuart, C. A.; Davis-Street, J.; Wolfe, R. R.

    1996-01-01

    We sought to determine the extent to which the loss of lean body mass and nitrogen during inactivity was due to alterations in skeletal muscle protein metabolism. Six male subjects were studied during 7 days of diet stabilization and after 14 days of stimulated microgravity (-6 degrees bed rest). Nitrogen balance became more negative (P protein synthesis (PS; P protein also decreased by 46% (P protein breakdown and inward transport. Whole body protein synthesis determined by [15N]alanine ingestion on six subjects also revealed a 14% decrease (P protein breakdown change significantly. These results indicate that the loss of body protein with inactivity is predominantly due to a decrease in muscle PS and that this decrease is reflected in both whole body and skeletal muscle measures.

  10. Circumference estimation using 3D-whole body scanners and shadow scanner

    NARCIS (Netherlands)

    Daanen, H.A.M.

    1998-01-01

    Clothing designers and manufacturers use traditional body dimensions as their basis. When 3D-whole body scanners are introduced to determine the body dimensions, a conversion has to be made, since scan determined circumference measures are slightly larger than the traditional values. This pilot

  11. Polyarteritis nodosa: MDCT as a 'One-Stop Shop' Modality for Whole-Body Arterial Evaluation

    International Nuclear Information System (INIS)

    Tsai, W.-L.; Tsai, I-C.; Lee Tain; Hsieh, C.-W.

    2008-01-01

    Polyarteritis nodosa is a rare disease, which is characterized by aneurysm formation and occlusion in the arteries of multiple systems. Due to its extensive involvement, whole-body evaluation is necessary for diagnosis and treatment monitoring. We report a case of polyarteritis nodosa using multidetector-row computed tomography (MDCT) as a 'one-stop shop' modality for whole-body arterial evaluation. With precise protocol design, MDCT can be used as a reliable noninvasive modality providing comprehensive whole-body arterial evaluation.

  12. Quantitative response of bone marrow colony-forming units (CFU-C and PFU-C) in weaning beagles exposed to acute whole-body γ irradiation

    International Nuclear Information System (INIS)

    Wilson, F.D.; Stitzel, K.A.; Klein, A.K.; Shifrine, M.; Graham, R.; Jones, M.; Bradley, E.; Rosenblatt, L.S.

    1978-01-01

    Using a methylcellulose-supported bone marrow culture system, the dose-response relationships of suspended granulocyte-monocyte colonies (CFU-C) and adherent fibroblastic colonies (PFU-C) were investigated in 2- to 3-month-old beagles exposed to acute whole-body γ irradiation. Groups of weanling beagles were exposed at a rate of 140 R/hr delivered from a 60 Co γ source achieving total exposures ranging from 0 to 586 R. Twenty-four hours following irradiation, bone marrow was collected, plated into methylcellulose, and after 1 week of incubation both colony types were quantitated. In addition, bone marrow cellularity determinations were made for a variety of bones using an 59 Fe-labeling technique. The results show a D 37 for the linear part of the slope of 70 R for CFU-C. Although within the limits of the experiment a D 37 could not be established for the fibroblastic populations, the results indicate a substantial degree of radioresistance for these elements supporting our previous studies on PFU-C, performed on mice, which suggested a D 37 of approximately 400 R for the progenitors of these fibroblastic elements

  13. The contribution of the body and motion to whole person recognition.

    Science.gov (United States)

    Simhi, Noa; Yovel, Galit

    2016-05-01

    While the importance of faces in person recognition has been the subject of many studies, there are relatively few studies examining recognition of the whole person in motion even though this most closely resembles daily experience. Most studies examining the whole body in motion use point light displays, which have many advantages but are impoverished and unnatural compared to real life. To determine which factors are used when recognizing the whole person in motion we conducted two experiments using naturalistic videos. In Experiment 1 we used a matching task in which the first stimulus in each pair could either be a video or multiple still images from a video of the full body. The second stimulus, on which person recognition was performed, could be an image of either the full body or face alone. We found that the body contributed to person recognition beyond the face, but only after exposure to motion. Since person recognition was performed on still images, the contribution of motion to person recognition was mediated by form-from-motion processes. To assess whether dynamic identity signatures may also contribute to person recognition, in Experiment 2 we presented people in motion and examined person recognition from videos compared to still images. Results show that dynamic identity signatures did not contribute to person recognition beyond form-from-motion processes. We conclude that the face, body and form-from-motion processes all appear to play a role in unfamiliar person recognition, suggesting the importance of considering the whole body and motion when examining person perception. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Whole body acid-base modeling revisited.

    Science.gov (United States)

    Ring, Troels; Nielsen, Søren

    2017-04-01

    The textbook account of whole body acid-base balance in terms of endogenous acid production, renal net acid excretion, and gastrointestinal alkali absorption, which is the only comprehensive model around, has never been applied in clinical practice or been formally validated. To improve understanding of acid-base modeling, we managed to write up this conventional model as an expression solely on urine chemistry. Renal net acid excretion and endogenous acid production were already formulated in terms of urine chemistry, and we could from the literature also see gastrointestinal alkali absorption in terms of urine excretions. With a few assumptions it was possible to see that this expression of net acid balance was arithmetically identical to minus urine charge, whereby under the development of acidosis, urine was predicted to acquire a net negative charge. The literature already mentions unexplained negative urine charges so we scrutinized a series of seminal papers and confirmed empirically the theoretical prediction that observed urine charge did acquire negative charge as acidosis developed. Hence, we can conclude that the conventional model is problematic since it predicts what is physiologically impossible. Therefore, we need a new model for whole body acid-base balance, which does not have impossible implications. Furthermore, new experimental studies are needed to account for charge imbalance in urine under development of acidosis. Copyright © 2017 the American Physiological Society.

  15. Whole-body angular momentum during stair ascent and descent.

    Science.gov (United States)

    Silverman, Anne K; Neptune, Richard R; Sinitski, Emily H; Wilken, Jason M

    2014-04-01

    The generation of whole-body angular momentum is essential in many locomotor tasks and must be regulated in order to maintain dynamic balance. However, angular momentum has not been investigated during stair walking, which is an activity that presents a biomechanical challenge for balance-impaired populations. We investigated three-dimensional whole-body angular momentum during stair ascent and descent and compared it to level walking. Three-dimensional body-segment kinematic and ground reaction force (GRF) data were collected from 30 healthy subjects. Angular momentum was calculated using a 13-segment whole-body model. GRFs, external moment arms and net joint moments were used to interpret the angular momentum results. The range of frontal plane angular momentum was greater for stair ascent relative to level walking. In the transverse and sagittal planes, the range of angular momentum was smaller in stair ascent and descent relative to level walking. Significant differences were also found in the ground reaction forces, external moment arms and net joint moments. The sagittal plane angular momentum results suggest that individuals alter angular momentum to effectively counteract potential trips during stair ascent, and reduce the range of angular momentum to avoid falling forward during stair descent. Further, significant differences in joint moments suggest potential neuromuscular mechanisms that account for the differences in angular momentum between walking conditions. These results provide a baseline for comparison to impaired populations that have difficulty maintaining dynamic balance, particularly during stair ascent and descent. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. The A.E.E. Winfrith Whole Body Monitor

    International Nuclear Information System (INIS)

    Peabody, C.O.; Fraser, V.M.; Speight, R.G.

    1962-10-01

    The function, design and construction of the A.E.E. Winfrith Whole Body Monitor are described. The main purpose of the monitor is to measure gamma emitting radioisotopes in the human body. Its performance, capabilities and limitations are discussed and a summary is given of experience gained and results obtained during the first few months of operation. The future programme of measurements and development is outlined. Some basic design criteria are put forward as a result of the experience and results obtained. (author)

  17. Whole body autoradiography with mice using 14C-thymidine

    International Nuclear Information System (INIS)

    Hruby, R. et al

    1982-06-01

    Whole body autoradiography was performed using common histology equipment. Results were useful with some restrictions. 14C-thymidine and/or itsmetabolites were found in those tissues with high rate of mitosis. (Author)

  18. Stability of Phase Relationships While Coordinating Arm Reaches with Whole Body Motion.

    Directory of Open Access Journals (Sweden)

    Romy S Bakker

    Full Text Available The human movement repertoire is characterized by the smooth coordination of several body parts, including arm movements and whole body motion. The neural control of this coordination is quite complex because the various body parts have their own kinematic and dynamic properties. Behavioral inferences about the neural solution to the coordination problem could be obtained by examining the emerging phase relationship and its stability. Here, we studied the phase relationships that characterize the coordination of arm-reaching movements with passively-induced whole-body motion. Participants were laterally translated using a vestibular chair that oscillated at a fixed frequency of 0.83 Hz. They were instructed to reach between two targets that were aligned either parallel or orthogonal to the whole body motion. During the first cycles of body motion, a metronome entrained either an in-phase or an anti-phase relationship between hand and body motion, which was released at later cycles to test phase stability. Results suggest that inertial forces play an important role when coordinating reaches with cyclic whole-body motion. For parallel reaches, we found a stable in-phase and an unstable anti-phase relationship. When the latter was imposed, it readily transitioned or drifted back toward an in-phase relationship at cycles without metronomic entrainment. For orthogonal reaches, we did not find a clear difference in stability between in-phase and anti-phase relationships. Computer simulations further show that cost models that minimize energy expenditure (i.e. net torques or endpoint variance of the reach cannot fully explain the observed coordination patterns. We discuss how predictive control and impedance control processes could be considered important mechanisms underlying the rhythmic coordination of arm reaches and body motion.

  19. Integrating Cellular Metabolism into a Multiscale Whole-Body Model

    Science.gov (United States)

    Krauss, Markus; Schaller, Stephan; Borchers, Steffen; Findeisen, Rolf; Lippert, Jörg; Kuepfer, Lars

    2012-01-01

    Cellular metabolism continuously processes an enormous range of external compounds into endogenous metabolites and is as such a key element in human physiology. The multifaceted physiological role of the metabolic network fulfilling the catalytic conversions can only be fully understood from a whole-body perspective where the causal interplay of the metabolic states of individual cells, the surrounding tissue and the whole organism are simultaneously considered. We here present an approach relying on dynamic flux balance analysis that allows the integration of metabolic networks at the cellular scale into standardized physiologically-based pharmacokinetic models at the whole-body level. To evaluate our approach we integrated a genome-scale network reconstruction of a human hepatocyte into the liver tissue of a physiologically-based pharmacokinetic model of a human adult. The resulting multiscale model was used to investigate hyperuricemia therapy, ammonia detoxification and paracetamol-induced toxication at a systems level. The specific models simultaneously integrate multiple layers of biological organization and offer mechanistic insights into pathology and medication. The approach presented may in future support a mechanistic understanding in diagnostics and drug development. PMID:23133351

  20. Calibration of Single High Purity Germanium Detector for Whole Body Counter

    International Nuclear Information System (INIS)

    Taha, T.M.; Morsi, T.M.

    2009-01-01

    A new Accuscan II single germanium detector for whole body counter was installed in NRC (Egypt). The current paper concerned on calibration of single high purity germanium detector for whole body counter. Physical parameters affecting on performance of whole body counter such as linearity, minimum detectable activity and source detector distance, SDD were investigated. Counting efficiencies for the detector have been investigated in rear wall, fixed diagnostic position in air. Counting efficiencies for organ compartments such as thyroid, lung, upper and lower gastrointestinal tract have been investigated using transfer phantom in fixed diagnostic and screening positions respectively. The organ compartment efficiencies in screening geometry were higher than that value of diagnostic geometry by a factor of three. The committed dose equivalents of I-131 in thyroid were ranged from 0.073 ± 0.004 to 1.73±0.09 mSv and in lung was 0.02±0.001 mSv

  1. Exercise Enhances Whole-Body Cholesterol Turnover in Mice

    NARCIS (Netherlands)

    Meissner, Maxi; Havinga, Rick; Boverhof, Renze; Kema, Ido; Groen, Albert K.; Kuipers, Folkert

    MEISSNER, M., R. HAVINGA, R. BOVERHOF, I. KEMA, A. K. GROEN, and F. KUIPERS. Exercise Enhances Whole-Body Cholesterol Turnover in Mice. Med. Sci. Sports Exerc., Vol. 42, No. 8, pp. 1460-1468, 2010. Purpose: Regular exercise reduces cardiovascular risk in humans by reducing cholesterol levels, but

  2. Whole body autoradiography, ch. 13

    International Nuclear Information System (INIS)

    Jonkman, J.H.G.

    1977-01-01

    The distribution of 35 S-ringlabelled thiazinamium methylsulphate has been studied by means of whole body autoradiography in a squirrel and in mice. Accumulation of activity was found in liver, kidney and intestines (the excretion of pathways). High concentrations were also found in organs with high amount of acetylcholine receptors and in the glandular tissue. No radioactivity was seen in the central nervous system, indicating no passage through the 'blood-brain barrier'. This is the most significant difference with its tertiary analogue Prometharine hydrochloride. In pregnant mice, high concentrations were found in the placenta but only low amounts were found in liver and kidneys of the foetuses

  3. Conjugate whole-body scanning system for quantitative measurement of organ distribution in vivo

    International Nuclear Information System (INIS)

    Tsui, B.M.W.; Chen, C.T.; Yasillo, N.J.; Ortega, C.J.; Charleston, D.B.; Lathrop, K.A.

    1979-01-01

    The determination of accurate, quantitative, biokinetic distribution of an internally dispersed radionuclide in humans is important in making realistic radiation absorbed dose estimates, studying biochemical transformations in health and disease, and developing clinical procedures indicative of abnormal functions. In order to collect these data, a whole-body imaging system is required which provides both adequate spatial resolution and some means of absolute quantitation. Based on these considerations, a new whole-body scanning system has been designed and constructed that employs the conjugate counting technique. The conjugate whole-body scanning system provides an efficient and accurate means of collecting absolute quantitative organ distribution data of radioactivity in vivo

  4. Nasal reaction to changes in whole body temperature.

    Science.gov (United States)

    Lundqvist, G R; Pedersen, O F; Hilberg, O; Nielsen, B

    1993-11-01

    The changes in nasal patency following a 1.5 degrees C decrease or increase in whole body temperature were measured in 8 healthy young males, during and after 30 min of immersion in a 15 degrees C cold or a 40 degrees C warm bath, breathing air at the same temperature, in a cross-over experimental design. The nasal reactions were traced by consecutive measurements of changes in nasal cavity volumes by acoustic rhinometry. Swelling of the mucosa during cooling and an almost maximal shrinkage of the mucosa during heating were indicated by respectively a decrease and an increase in nasal cavity volumes. The reactions were determined predominantly by the whole body thermal balance, but were also influenced by the temperature of the inhaled air, either enhanced, reduced or temporarily reversed. The greatest change occurred in the nasal cavity, left or right, which differed most from the final state at the beginning of exposure due to the actual state of nasal cycle.

  5. An investigation into the potassium body burden in humans with the help of a whole-body counter

    International Nuclear Information System (INIS)

    Selzer, A.

    1981-01-01

    The purpose of this study was to examine the available information concerning the potassium body burden of a large number of adults and to find a correlation with other easily measurable body parameters such as mass, height and age so that a normal expected body potassium may be predicted for patients with potassium abnormalities who are also referred to the whole-body counter. The calibration of the whole-body counter to make provision for the differences in geometry and absorption in various body sizes was carried out by injecting a number of people with a small dose of potassium-42 and calculating a correction factor for the potassium standard which is in use daily. All measurements of body potassium were corrected with the calculated correction factor. Fatty tissue in the body contains very little potassium in comparison with muscle tissue and a better correction should therefore be obtained between body potassium and lean body mass. Although it is not possible to predict the smaller potassium abnormalities even when lean body mass is used, the derived regression equation in which lean body mass and age are used, may be viewed as a good first approach in the advance estimation of body potassium

  6. The Peripheral Whole Blood Transcriptome of Acute Pyelonephritis in Human Pregnancy

    Science.gov (United States)

    Madan, Ichchha; Than, Nandor Gabor; Romero, Roberto; Chaemsaithong, Piya; Miranda, Jezid; Tarca, Adi L.; Bhatti, Gaurav; Draghici, Sorin; Yeo, Lami; Mazor, Moshe; Hassan, Sonia S.; Chaiworapongsa, Tinnakorn

    2018-01-01

    Objective Human pregnancy is characterized by activation of the innate immune response and suppression of adaptive immunity. The former is thought to provide protection against infection to the mother, and the latter, tolerance against paternal antigens expressed in fetal cells. Acute pyelonephritis is associated with an increased risk of acute respiratory distress syndrome and sepsis in pregnant (vs. nonpregnant) women. The objective of this study was to describe the gene expression profile (transcriptome) of maternal whole blood in acute pyelonephritis. Method A case-control study was conducted to include pregnant women with acute pyelonephritis (n=15) and women with a normal pregnancy (n=34). Affymetrix HG-U133 Plus 2.0 arrays (Affymetrix, Santa Clara, CA, USA) were used for gene expression profiling. A linear model was used to test the association between the presence of pyelonephritis and gene expression levels while controlling for white blood cell count and gestational age. A fold change of 1.5 was considered significant at a false discovery rate of 0.1. A subset of differentially expressed genes (n=56) was tested with real-time quantitative reverse transcription-polymerase chain reaction (qRT-PCR) (cases, n=19; controls, n=59). Gene ontology and pathway analysis were applied. Results A total of 983 genes were differentially expressed in acute pyelonephritis: 457 were up-regulated and 526 were down-regulated. Significant enrichment of 300 biological processes and 63 molecular functions was found in pyelonephritis. Significantly impacted pathways in pyelonephritis included a) cytokine-cytokine receptor interaction; b) T-cell receptor signaling; c) Jak-STAT signaling; and d) complement and coagulation cascades. Of 56 genes tested by qRT-PCR, 48 (85.7%) had confirmation of differential expression. Conclusion This is the first study of the transcriptomic signature of whole blood in pregnant women with acute pyelonephritis. Acute infection during pregnancy is

  7. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.j [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  8. The Early Result of Whole Pelvic Radiotherapy and Stereotactic Body Radiotherapy Boost for High Risk Localized Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Yu-Wei eLin

    2014-10-01

    Full Text Available PurposeThe rationale for hypofractionated radiotherapy in the treatment of prostate cancer is based on the modern understanding of radiobiology and advances in stereotactic body radiotherapy (SBRT techniques. Whole-pelvis irradiation combined with SBRT boost for high-risk prostate cancer might escalate biologically effective dose without increasing toxicity. Here, we report our 4-year results of SBRT boost for high-risk localized prostate cancer.Methods and MaterialsFrom October 2009 to August 2012, 41 patients of newly diagnosed, high-risk or very high-risk (NCCN definition localized prostate cancer patients were treated with whole-pelvis irradiation and SBRT boost. The whole pelvis dose was 45Gy (25 fractions of 1.8Gy. The SBRT boost dose was 21 Gy (three fractions of 7 Gy. Ninety percent of these patients received hormone therapy. The toxicities of gastrointestinal (GI and genitourinary (GU tracts were scored by Common Toxicity Criteria Adverse Effect (CTCAE v3.0. Biochemical failure was defined by Phoenix definition.ResultsMedian follow-up was 42 months. Mean PSA before treatment was 44.18 ng/ml. Mean PSA level at 3, 6, 12, 18, and 24 months was 0.94, 0.44, 0.13, 0.12, and 0.05 ng/ml, respectively. The estimated 4-year biochemical failure-free survival was 91.9%. Three biochemical failures were observed. GI and GU tract toxicities were minimal. No grade 3 acute GU or GI toxicity was noted. During radiation therapy, 27% of the patient had grade 2 acute GU toxicity and 12% had grade 2 acute GI toxicity. At 3 months, most toxicity scores had returned to baseline. At the last follow up, there was no grade 3 late GU or GI toxicity.ConclusionsWhole-pelvis irradiation combined with SBRT boost for high-risk localized prostate cancer is feasible with minimal toxicity and encouraging biochemical failure-free survival. Continued accrual and follow-up would be necessary to confirm the biochemical control rate and the toxicity profiles.

  9. Antihysteresis of perceived longitudinal body axis during continuous quasi-static whole-body rotation in the earth-vertical roll plane.

    Science.gov (United States)

    Tatalias, M; Bockisch, C J; Bertolini, G; Straumann, D; Palla, A

    2011-03-01

    Estimation of subjective whole-body tilt in stationary roll positions after rapid rotations shows hysteresis. We asked whether this phenomenon is also present during continuous quasi-static whole-body rotation and whether gravitational cues are a major contributing factor. Using a motorized turntable, 8 healthy subjects were rotated continuously about the earth-horizontal naso-occipital axis (earth-vertical roll plane) and the earth-vertical naso-occipital axis (earth-horizontal roll plane). In both planes, three full constant velocity rotations (2°/s) were completed in clockwise and counterclockwise directions (acceleration = 0.05°/s(2), velocity plateau reached after 40 s). Subjects adjusted a visual line along the perceived longitudinal body axis (pLBA) every 2 s. pLBA deviation from the longitudinal body axis was plotted as a function of whole-body roll position, and a sine function was fitted. At identical whole-body earth-vertical roll plane positions, pLBA differed depending on whether the position was reached by a rotation from upright or by passing through upside down. After the first 360° rotation, pLBA at upright whole-body position deviated significantly in the direction of rotation relative to pLBA prior to rotation initiation. This deviation remained unchanged after subsequent full rotations. In contrast, earth-horizontal roll plane rotations resulted in similar pLBA before and after each rotation cycle. We conclude that the deviation of pLBA in the direction of rotation during quasi-static earth-vertical roll plane rotations reflects static antihysteresis and might be a consequence of the known static hysteresis of ocular counterroll: a visual line that is perceived that earth-vertical is expected to be antihysteretic, if ocular torsion is hysteretic.

  10. Whole body measurements in Bavarian school children

    International Nuclear Information System (INIS)

    Schmier, H.; Berg, D.

    1992-12-01

    On behalf of the Bavarian State Ministry for State Development and Environmental Affairs measurements were conducted using the whole body counters at the Institute for Radiation Hygiene (of the Federal Office for Radiation Protection), and the Institute for Radiation Biology (of the GSF Research Centre for Environment and Health). Between September 1988 and July 1990 about 1600 school children from all over Bavaria were investigated for incorporated radiocesium. The aim of these measurements was to evaluate the whole body activity due to regionally differing soil contaminations in Bavaria following the accident in the nuclear power plant in Chernobyl and to assess the effective dose from an intake of radionuclides for the pupils by comparing the results of their WBC measurements with those of reference groups of children which underwent WBC examinations at regular intervals at both institutes since the middle of the year 1986. The results of the WBC measurements of those pupils who had not eaten mushrooms in the days before the measurement are in good agreement with the results of comparative measurements in children living in the regions of Munich and Frankfurt-am-Main. Based on these results an effective dose of 0,2 mSv for the Munich region children and of 0,1 mSv for Nothern Bavarian children can be derived. For children living in the highest contaminated region of Bavaria, i.e. the counties adjacent to the Alps, no comparable reference group results are available, but the amount of incorporated radiocesium is only twice that for pupils in the Munich region. The mean value for the specific activity of radiocesium in South Bavarian school children who consumed mushrooms was found to be twice the value of pupils who did not. This is also true for that group of children whose parents had bought allegedly low contaminated foodstuffs. Other effecs of nutrition habits on the specific whole body activity could not be found. (orig.) [de

  11. The influence of dietary and whole-body nutrient content on the excretion of a vertebrate consumer.

    Directory of Open Access Journals (Sweden)

    Christopher M Dalton

    Full Text Available In many contexts, nutrient excretion by consumers can impact ecosystems by altering the availability of limiting nutrients. Variation in nutrient excretion can be predicted by mass balance models, most of which are premised on two key ideas: (1 consumers maintain fixed whole-body nutrient content (i.e., %N and %P, so-called fixed homeostasis; (2 if dietary nutrients are not matched to whole-body nutrients, excesses of any nutrient are released as excretion to maintain fixed homeostasis. Mass balance models thus predict that consumer excretion should be positively correlated with diet nutrients and negatively correlated with whole-body nutrients. Recent meta-analyses and field studies, however, have often failed to find these expected patterns, potentially because of a confounding influence-flexibility in whole-body nutrient content with diet quality (flexible homeostasis. Here, we explore the impact of flexible homeostasis on nutrient excretion by comparing the N and P excretion of four genetically diverged Trinidadian guppy (Poecilia reticulata populations when reared on diets of variable P content. As predicted by mass balance, P excretion increased on the high-P diet, but, contrary to the notion of fixed homeostasis, guppy whole-body %P also increased on the high-P diet. While there was no overall correlation between excretion nutrients and whole-body nutrients, when the effect of diet on both whole-body and excretion nutrients was included, we detected the expected negative correlation between whole-body N:P and excretion N:P. This last result suggests that mass balance can predict excretion rates within species, but only if dietary effects on whole-body nutrient content are controlled. Flexible homeostasis can obscure patterns predicted by mass balance, creating an imperative to accurately capture an organism's diet quality in predicting its excretion rate.

  12. Whole-body magnetic resonance imaging in inflammatory arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Eshed, Iris; Althoff, Christian E.

    2017-01-01

    Objective: Whole-body magnetic resonance imaging (WB-MRI) is a relatively new technique that can enable assessment of the overall inflammatory status of people with arthritis, but standards for image acquisition, definitions of key pathologies, and a quantification system are required. Our aim...... was to perform a systematic literature review (SLR) and to develop consensus definitions of key pathologies, anatomical locations for assessment, a set of MRI sequences and imaging planes for the different body regions, and a preliminary scoring system for WB-MRI in inflammatory arthritis. Methods: An SLR...

  13. Segmentation and visual analysis of whole-body mouse skeleton microSPECT.

    Directory of Open Access Journals (Sweden)

    Artem Khmelinskii

    Full Text Available Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability. The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers (99mTc-methylene diphosphonate ((99mTc-MDP and (99mTc-hydroxymethane diphosphonate ((99mTc-HDP were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for "incomplete" data (large chunks of skeleton missing and for an intuitive exploration and comparison of multi-modal SPECT

  14. Integrating cellular metabolism into a multiscale whole-body model.

    Directory of Open Access Journals (Sweden)

    Markus Krauss

    Full Text Available Cellular metabolism continuously processes an enormous range of external compounds into endogenous metabolites and is as such a key element in human physiology. The multifaceted physiological role of the metabolic network fulfilling the catalytic conversions can only be fully understood from a whole-body perspective where the causal interplay of the metabolic states of individual cells, the surrounding tissue and the whole organism are simultaneously considered. We here present an approach relying on dynamic flux balance analysis that allows the integration of metabolic networks at the cellular scale into standardized physiologically-based pharmacokinetic models at the whole-body level. To evaluate our approach we integrated a genome-scale network reconstruction of a human hepatocyte into the liver tissue of a physiologically-based pharmacokinetic model of a human adult. The resulting multiscale model was used to investigate hyperuricemia therapy, ammonia detoxification and paracetamol-induced toxication at a systems level. The specific models simultaneously integrate multiple layers of biological organization and offer mechanistic insights into pathology and medication. The approach presented may in future support a mechanistic understanding in diagnostics and drug development.

  15. Comparison of whole body MR diffusion weighted imaging and skeletal scintigraphy in detecting bone metastasis

    International Nuclear Information System (INIS)

    Xu Xian; Ma Lin; Zhang Jinshan; Cai Youquan; Cheng Liuquan; Guo Xinggao; Xu Baixuan

    2008-01-01

    Objective: To evaluate the application of whole body MR diffusion weighted imaging (DWI) in the detection of bone metastasis using skeletal scintigraphy as the reference. Methods: Forty-two healthy volunteers and 38 patients with malignant tumors were enrolled in our study. All the patients received MR examination and skeletal scintigraphy within one week. MR examination was performed on GE signa 3.0T MR scanner using a build-in body coil. The skeletal system was divided into eight regions and the images of the whole body MR DWI and skeletal scintigraphy were reviewed to compare the two modalities patient by patient and region by region. The images were reviewed separately by two radiologists and two nuclear medicine physicians, who were blinded to the results of another imaging modality. Results: A total of 169 metastatic lesions in 69 regions of 30 patients were detected by whole body MR DWI while 156 lesions in 68 regions of 29 patients were identified by skeletal scintigraphy. There were two cases negative in scintigraphy but positive in whole body MR DWI and one case positive in scintigraphy only. There were eight lesions negative in scintigraphy but positive in whole body MR DWI, mainly located in the spine, pelvis and femur. Seven lesions were only detected by scintigraphy, mainly located in the skull, sternum, clavicle and scapula. Conclusion: The whole body MR DWI reveals excellent consistency with skeletal scintigraphy regarding bone metastasis, and the two modalities are complementary for each other. (authors)

  16. Effect of alcohol consumption on whole-body protein turnover in healthy adults.

    Science.gov (United States)

    Wutzke, Klaus D; Krentz, Helga; Bruns, Gerrit

    2011-03-01

    The aim of the study was to investigate the whole-body protein turnover, either before or after continuous, moderate ethanol-induced oxidative stress by red wine consumption over a relatively short period in healthy volunteers. Ten healthy adults received an individual regular diet over 20 days. After 10 days, the subjects consumed 0.4 ml ethanol kg(-1) day(-1) as red wine together with dinner over a 10-day period. After 8 and 18 days, respectively, a (15)N-labelled yeast protein was administered in a dosage of 4.2 mg kg(-1) body weight. Urine and faeces were collected over 48 h, respectively. The (15)N-enrichment was measured by isotope ratio mass spectrometry, whereas the protein flux rates were calculated by a three-compartment model. The whole-body protein turnover without/with red wine consumption amounted to 3.73±0.6 and 3.49±0.6 g kg(-1) day(-1) (not significant), respectively. Moderate alcohol consumption does not induce significant short-term changes in the whole-body protein turnover of healthy adults.

  17. Salivary steroid hormone response to whole-body cryotherapy in elite rugby players.

    Science.gov (United States)

    Grasso, D; Lanteri, P; Di Bernardo, C; Mauri, C; Porcelli, S; Colombini, A; Zani, V; Bonomi, F G; Melegati, G; Banfi, G; Lombardi, G

    2014-01-01

    Saliva represents a low stress, not-invasively collected matrix that allows steroid hormone monitoring in athletes by reflecting type, intensity and duration of exercise. Whole body cryotherapy (WBC) consists of short whole-body exposures to extremely cold air (-110° to -140°C) which, despite being initially used to treat inflammatory diseases, is currently acquiring increasing popularity in sports medicine. Cryostimulation practice is now widely accepted as an effective treatment to accelerate muscle recovery in rugby players. The aim of this work was to study the changes of steroid hormones in saliva of rugby players after both 2 and 14 consecutive WBC sessions, in order to investigate the effects of the treatment on their salivary steroid hormonal profile. Twenty-five professional rugby players, belonging to the Italian National Team, underwent a 7-day cryotherapy protocol consisting of 2 daily sessions. Saliva samples were taken in the morning prior to the start of the WBC, in the evening after the end of the second WBC, and in the morning of the day after the last WBC session. The samples were analyzed for cortisol, DHEA, testosterone and estradiol using competitive enzyme-linked immunosorbent assays. Cortisol and DHEA showed a reduction already after the 2 WBC sessions of the first day; after 14 consecutive WBC sessions cortisol, DHEA, and estradiol levels decreased, while testosterone increased as did the testosterone to cortisol ratio. These results were confirmed by the fact that the majority of subjects showed variations exceeding the critical difference (CD). In conclusion, we found that WBC acutely affects the salivary steroid hormone profile, and the results are evident already after only one twice-daily session. Most significantly, after one-week of consecutive twice-daily WBC sessions, all the hormones were modified. This is the first experimental report that links changes in the hormonal asset to WBC.

  18. Caffeine protects mice against whole-body lethal dose of {gamma}-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    George, K.C.; Hebbar, S.A.; Kale, S.P.; Kesavan, P.C. [Biosciences Group, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    1999-06-01

    Administration of caffeine (1,3,7-trimethylxanthine), a major component of coffee, to Swiss mice at doses of 80 or 100 mg/kg body weight 60 min prior to whole-body lethal dose of {gamma}-irradiation (7.5 Gy) resulted in the survival of 70 and 63% of animals, respectively, at the above doses in contrast to absolutely no survivors (LD-100/25 days) in the group exposed to radiation alone. Pre-treatment with a lower concentration of caffeine (50 mg/kg) did not confer any radioprotection. The protection exerted by caffeine (80 mg/kg), however, was reduced from 70 to 50% if administered 30 min prior to irradiation. The trend statistics reveal that a dose of 80 mg/kg administered 60 min before whole-body exposure to 7.5 Gy is optimal for maximal radioprotection. However, caffeine (80 mg/kg) administered within 3 min after irradiation offered no protection. While there is documentation in the literature that caffeine is an antioxidant and radioprotector against the toxic pathway of radiation damage in a wide range of cells and organisms, this is the first report demonstrating unequivocally its potent radioprotective action in terms of survival of lethally whole-body irradiated mice. (author)

  19. Correlates of whole-blood polyunsaturated fatty acids among young children with moderate acute malnutrition.

    Science.gov (United States)

    Yaméogo, C W; Cichon, B; Fabiansen, C; Rytter, M J H; Faurholt-Jepsen, D; Stark, K D; Briend, A; Shepherd, S; Traoré, A S; Christensen, V B; Michaelsen, K F; Friis, H; Lauritzen, L

    2017-07-13

    Severe acute malnutrition (SAM) has been associated with low polyunsaturated fatty acid (PUFA) status. However, investigations regarding PUFA status and correlates in children with moderate acute malnutrition (MAM) from low-income countries are scarce. The aim of this study was to describe whole-blood PUFA levels in children with moderate acute malnutrition (MAM) and to identify correlates of PUFAs. We conducted a cross-sectional study using baseline data from a prospective nutritional intervention trial among 1609 children with MAM aged 6-23 months in Burkina Faso,West Africa. Whole-blood PUFAs were measured by gas chromatography and expressed as percent of total whole-blood fatty acids (FA%). Potential correlates of PUFAs including infection, inflammation, hemoglobin, anthropometry (difference between children diagnosed as having MAM based on low mid-upper-arm-circumference (MUAC) only, low MUAC and weight-for-height z-score (WHZ), or low WHZ only) and diet were assessed by linear regression adjusted for age and sex. Children with MAM had low concentrations of whole-blood PUFAs, particularly n-3 PUFAs. Moreover, children diagnosed with MAM based only on low MUAC had 0.32 (95% confidence interval (CI), 0.14; 0.50) and 0.40 (95% CI, 0.16; 0.63) FA% lower arachidonic acid (AA) than those recruited based on both low WHZ as well as low MUAC and those recruited with low WHZ only, respectively. Infection and inflammation were associated with low levels of all long-chain (LC)-PUFAs, while hemoglobin was positively associated with whole-blood LC-PUFAs. While PUFA deficiency was not a general problem, overall whole-blood PUFA concentrations, especially of n-3 PUFAs, were low. Infection, inflammation, hemoglobin, anthropometry and diet were correlates of PUFAs concentrations in children with MAM. The trial is registered at http://www.isrctn.com ( ISRCTN42569496 ).

  20. Experience with a mobile whole body counting screening program at Ontario Hydro

    International Nuclear Information System (INIS)

    Wong, K.Y.

    1976-01-01

    A whole-body counting program using a trailer-mounted counter has been in service in Ontario Hydro since 1972 to monitor routinely internal uptakes of radionuclides by nuclear station employees. The philosophy and objectives of the program are discussed; equipment and calibration procedures are described, and experience over the past two and a half years is reviewed. The procedures to minimize the effects of external contamination, a problem commonly encountered in whole-body counting, are described. (auth)

  1. Synthesis of dendrimer-based biotin radiopharmaceuticals to enhance whole-body clearance

    International Nuclear Information System (INIS)

    Sato, Noriko; Park, Chang W.; Kim, Hyung-Sik; Han, Eui-Sik; Wong, Karen J.; Paik, Ronald S.; Park, Luke S.; Yao Zhengsheng; Carrasquillo, Jorge A.; Paik, Chang H.

    2003-01-01

    To synthesize a biotin radiopharmaceutical that clears rapidly, dendrimer was used as a carrier and conjugated with succinimidyl 3-[ 125 I]iodobenzoate and tetrafluorophenyl norbiotinamidosuccinate. Then, succinic anhydride was used to reduce its pI. In mice, the non-succinylated product showed high liver (67% ID/g) and kidney (44% ID/g) uptakes and whole-body retention (94% ID) at 20 min that persisted for 12 hr. The corresponding organ uptakes (22% and 11% ID/g) and the whole-body retention (47% ID) were drastically reduced by succinylation (p<0.0001). Lysine co-injection further lowered renal uptake

  2. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  3. Electrical stimulation of human lower extremities enhances energy consumption, carbohydrate oxidation, and whole body glucose uptake.

    Science.gov (United States)

    Hamada, Taku; Hayashi, Tatsuya; Kimura, Tetsuya; Nakao, Kazuwa; Moritani, Toshio

    2004-03-01

    Our laboratory has recently demonstrated that low-frequency electrical stimulation (ES) of quadriceps muscles alone significantly enhanced glucose disposal rate (GDR) during euglycemic clamp (Hamada T, Sasaki H, Hayashi T, Moritani T, and Nakao K. J Appl Physiol 94: 2107-2112, 2003). The present study is further follow-up to examine the acute metabolic effects of ES to lower extremities compared with voluntary cycle exercise (VE) at identical intensity. In eight male subjects lying in the supine position, both lower leg (tibialis anterior and triceps surae) and thigh (quadriceps and hamstrings) muscles were sequentially stimulated to cocontract in an isometric manner at 20 Hz with a 1-s on-off duty cycle for 20 min. Despite small elevation of oxygen uptake by 7.3 +/- 0.3 ml x kg(-1) x min(-1) during ES, the blood lactate concentration was significantly increased by 3.2 +/- 0.3 mmol/l in initial period (5 min) after the onset of the ES (P increased anaerobic glycolysis by ES. Furthermore, whole body glucose uptake determined by GDR during euglycemic clamp demonstrated a significant increase during and after the cessation of ES for at least 90 min (P energy consumption, carbohydrate oxidation, and whole body glucose uptake at low intensity of exercise. Percutaneous ES may become a therapeutic utility to enhance glucose metabolism in humans.

  4. Whole body cooling by immersion in water at moderate temperatures.

    Science.gov (United States)

    Marino, F; Booth, J

    1998-06-01

    This study investigated the potential use of whole body cooling by water immersion for lowering body temperatures prior to endurance exercise. Rectal temperature (Tre), mean skin temperature (Tsk), oxygen consumption (VO2), and ventilation (VE) were measured in 7 male and 3 female subjects who were immersed in a water bath for up to 60 min. Initial water temperature was 28.8+/-1.5 degrees C and decreased to 23.8+/-1.1 degrees C by the end of immersion. Pre-immersion Tre of 37.34+/-0.36 degrees C was not altered by 60 min water immersion but decreased to 36.64+/-0.34 degrees C at 3 min post immersion (p immersion. Reductions in Tre and Tsk resulted in reduced body heat content (Hc) of approximately 545 kJ (p immersion. VO2 and VE increased from pre-immersion values of 0.34+/-0.08 L x min(-1) and 6.2+/-1.4 L x min(-1) to 0.54+/-0.09 L x min(-) and 11.5+/-5.4 L x min(-1) at the end of immersion, respectively. Heart rate remained unchanged throughout immersion. These results indicate that whole body immersion in moderately cold water temperatures is an effective cooling maneuver for lowering body temperatures and body Hc in the absence of severe physiological responses generally associated with sudden cold stress.

  5. Automated analysis of whole skeletal muscle for muscular atrophy detection of ALS in whole-body CT images: preliminary study

    Science.gov (United States)

    Kamiya, Naoki; Ieda, Kosuke; Zhou, Xiangrong; Yamada, Megumi; Kato, Hiroki; Muramatsu, Chisako; Hara, Takeshi; Miyoshi, Toshiharu; Inuzuka, Takashi; Matsuo, Masayuki; Fujita, Hiroshi

    2017-03-01

    Amyotrophic lateral sclerosis (ALS) causes functional disorders such as difficulty in breathing and swallowing through the atrophy of voluntary muscles. ALS in its early stages is difficult to diagnose because of the difficulty in differentiating it from other muscular diseases. In addition, image inspection methods for aggressive diagnosis for ALS have not yet been established. The purpose of this study is to develop an automatic analysis system of the whole skeletal muscle to support the early differential diagnosis of ALS using whole-body CT images. In this study, the muscular atrophy parts including ALS patients are automatically identified by recognizing and segmenting whole skeletal muscle in the preliminary steps. First, the skeleton is identified by its gray value information. Second, the initial area of the body cavity is recognized by the deformation of the thoracic cavity based on the anatomical segmented skeleton. Third, the abdominal cavity boundary is recognized using ABM for precisely recognizing the body cavity. The body cavity is precisely recognized by non-rigid registration method based on the reference points of the abdominal cavity boundary. Fourth, the whole skeletal muscle is recognized by excluding the skeleton, the body cavity, and the subcutaneous fat. Additionally, the areas of muscular atrophy including ALS patients are automatically identified by comparison of the muscle mass. The experiments were carried out for ten cases with abnormality in the skeletal muscle. Global recognition and segmentation of the whole skeletal muscle were well realized in eight cases. Moreover, the areas of muscular atrophy including ALS patients were well identified in the lower limbs. As a result, this study indicated the basic technology to detect the muscle atrophy including ALS. In the future, it will be necessary to consider methods to differentiate other kinds of muscular atrophy as well as the clinical application of this detection method for early ALS

  6. Monte Carlo calculation of efficiencies of whole-body counter, by microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computer programming using the Monte Carlo method for calculation of efficiencies of whole-body counting of body radiation distribution is presented. An analytical simulator (for man e for child) incorporated with 99m Tc, 131 I and 42 K is used. (M.A.C.) [pt

  7. Determination of calibration factors for whole body counting of members of public

    International Nuclear Information System (INIS)

    Vijayagopal, P.; Joyeeta, M.; Garg, S.P.; Vidhani, J.M.; Pendharkar, K.A.

    2005-01-01

    A Mobile Radiological Laboratory (MRL) was recently developed by Internal Dosimetry Division in BARC. In the event of an accident involving release of radioactive substances into the environment, there will be a need to measure both the external and the internal exposure of the population. MRL has been equipped with a variety of radiation detectors, radiation survey meters and a whole body monitor for this purpose. For whole body monitoring of members of public, detector systems are required to be calibrated with the age dependent phantoms of appropriate size for both male and female subjects. In this paper we present the results of the calibration studies carried out with shielded chair whole body counter of MRL using five different age dependent male phantoms representing the age groups of 1,5,10 and 15 year old children and 20 year old adult. Calibration work has been carried out using standard sources of 137 Cs, 133 Ba and 60 Co. (author)

  8. [The effect of betahistine on histological changes in rabbit brain in model of whole body wide-frequency vibration].

    Science.gov (United States)

    Shimkus, Iu Iu; Sapegin, I D

    2013-01-01

    In acute experiments in conscious rabbits was studied protective action of selective blocker of histamine H3-receptor betahistine (2mg/kg i/v) against histological changes in precentral and postcentral gyrus, as well as in temporal lobe of cerebral cortex, thalamus, hypothalamus, and cerebellum, arising in case of modeling of whole body wide-frequency vibration. Betahistine attenuates edematous and degenerative changes in neurons and reciprocal glial reaction, caused by vibration, but does not eliminate edema in perivascular spaces. This effect may be related to the improvement of blood supply as a result of of vasodilatory action and decrease of oxygen consumption via vestibuloprotective effect.

  9. Whole body interaction with public displays

    CERN Document Server

    Walter, Robert

    2017-01-01

    This book develops valuable new approaches to digital out-of-home media and digital signage in urban environments. It offers solutions for communicating interactive features of digital signage to passers-by. Digital out-of-home media and digital signage screens are becoming increasingly interactive thanks to touch input technology and gesture recognition. To optimize their conversion rate, interactive public displays must 1) attract attention, 2) communicate to passers-by that they are interactive, 3) explain the interaction, and 4) provide a motivation for passers-by to interact. This book highlights solutions to problems 2 and 3 above. The focus is on whole-body interaction, where the positions and orientations of users and their individual body parts are captured by specialized sensors (e.g., depth cameras). The book presents revealing findings from a field study on communicating interactivity, a laboratory on analysing visual attention, a field study on mid-air gestures, and a field study on using mid-air...

  10. Assessment of exposure to whole body vibration in Yazd city taxi drivers

    Directory of Open Access Journals (Sweden)

    F Samoori sakhvidi

    2016-11-01

    Full Text Available Assessment of exposure to whole body vibration in Yazd city taxi drivers Samoori-Sakhvidi F (MSc* Barkhordari A (PhD** Dehghani A (PhD*** Tavakoli-Manesh S (MSc**** *Corresponding Author: MSc Student in Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran ** Professor, Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran *** Professor, Department of Statistics and Epidemiology, Shahid Sadoughi University of Medical Sciences, Yazd, Iran **** MSc Student in Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran Abstract Introduction: One of the most common sources of whole body vibration are vehicles in which the driver is exposed to vibration caused by the vehicle and the road. Including the people who continuously exposure to whole-body vibration can be noted to taxi drivers. Taxi drivers during their work shift Encountered with numerous deleterious effects such as noise, vibration, air pollution, and psychological stress and long work shifts. Long-term exposure to whole body vibration in the taxi drivers can communicate with adverse effects such as reduce perception, annoyance, disturbance of vision and fine motor tasks, spinal cord injury, damage to the digestive and reproductive systems. The purpose of this study was cross - sectional study of whole body vibration exposure in Yazd city taxi drivers. Methods: This study was designed to evaluate exposure to whole body vibration in taxi drivers, vibration measurement Was carried out in 80 taxi from 3 vehicle (Samand-Peugeot 405 and Pridein 3 mileage groups, with 63 male drivers and 17 female drivers. parameters Including the vibration Weighing the acceleration frequency (rms, Equivalent acceleration (Aeq and vibration doseVDV in 3-axis was recorded. The results obtained were compared with the values recommended by the standard (ISO 2631-1. Results: The mean (rms acceleration

  11. Effects of adding whole body vibration to squat training on isometric force/time characteristics.

    Science.gov (United States)

    Lamont, Hugh S; Cramer, Joel T; Bemben, Debra A; Shehab, Randa L; Anderson, Mark A; Bemben, Michael G

    2010-01-01

    Resistance training interventions aimed at increasing lower-body power and rates of force development have produced varying results. Recent studies have suggested that whole-body low-frequency vibration (WBLFV) may elicit an acute postactivation potentiation response, leading to acute improvements in power and force development. Potentially, the use of WBLFV between sets of resistance training rather than during training itself may lead to increased recruitment and synchronization of high-threshold motor units, minimize fatigue potential, and facilitate the chronic adaptation to resistance exercise. The purpose of this study was to determine the effects of applying TriPlaner, WBLFV, prior to and then intermittently between sets of Smith machine squats on short-term adaptations in explosive isometric force expression. Thirty recreationally resistance trained men aged 18-30 were randomly assigned to 1 of 3 groups: resistance training only (SQT, n = 11), resistance plus whole-body vibration (SQTV, n = 13), or active control (CON, n = 6). An isometric squat test was performed prior to and following a 6-week periodized Smith machine squat program. Whole-body low-frequency vibration was applied 180 seconds prior to the first work set (50 Hz, 2-4 mm, 30 seconds) and intermittently (50 Hz, 4-6 mm, 3 x 10 seconds, 60 seconds between exposures) within a 240-second interset rest period. Subjects were instructed to assume a quarter squat posture while positioning their feet directly under their center of mass, which was modified using a handheld goniometer to a knee angle of 135 +/- 5 degrees . Instructions were given to subjects to apply force as fast and as hard as possible for 3.5 seconds. Isometric force (N) and rates of force development (N.s(-1)) were recorded from the onset of contraction (F(0)) to time points corresponding to 30, 50, 80, 100, 150, and 250 milliseconds, as well as the peak isometric rate of force development (PISORFD), and rate of force development to

  12. Simplified calibration and evaluation procedures for improvised whole body gamma spectrometry in emergency situations

    International Nuclear Information System (INIS)

    Malatova, I.; Bucina, I.; Drabova, D.; Cespirova, I.

    2000-01-01

    A semiconductor gamma spectrometer could be used for the rapid estimation of internal contamination of the people in cases of accidents even when no special calibration for whole body counting is prepared. Generic transfer factors for calculation of the whole body detection efficiency from the 25 cm distant point source detection efficiency are presented. Generic dependence of parameters of power function describing the detector efficiency for point source in 25 cm on the detector relative efficiency given by producer was derived from calibration of 18 detectors with relative efficiency from 1.4% to 62%. Minimum detectable activity for various backgrounds and the uncertainty of the estimate of whole body retention are presented, too. (author)

  13. Effects of the whole-body cryotherapy on NTproBNP, hsCRP and troponin I in athletes.

    Science.gov (United States)

    Banfi, Giuseppe; Melegati, Gianluca; Barassi, Alessandra; d'Eril, Gianlodovico Melzi

    2009-11-01

    Whole-body cryotherapy refers to brief exposure to very cold air for treating symptoms of various illnesses. In sports medicine, whole-body cryotherapy is administered to improve recovery from muscular trauma. As specific studies are lacking, we measured cardiac markers in 10 top-level rugby players of the Italian National team before and after a 1-week course of daily sessions of whole-body cryotherapy. All subjects continued with the same training workload as that of the previous weeks. N-terminal pro B-type natriuretic peptide (NTproBNP) levels increased but remained within the normal range, whilst troponin I (TnI) and high sensitivity C-reactive protein (hsCRP) were unchanged. Whole-body cryotherapy did not impair cardiac function in this sample of elite athletes.

  14. A statistical observation on some subjects in the whole body computed tomographic examination

    International Nuclear Information System (INIS)

    Murakami, Shozo; Matsumoto, Shigekazu; Murakawa, Yasuhiro; Morimoto, Mitsuo; Nakai, Toshio

    1983-01-01

    Since the whole body CT (computed tomography) unit (GE, CT/T) was installed in our hospital in April, 1982, a total of 2884 cases have been examined by this whole body scanner for one year from April, 1982 to March, 1983. An analysis of the relationship between the situations of the subjects in and the results of whole body CT examination disclosed some very interesting facts. Up to the present time such a study has scarcely made. That is why we wanted to make this report. The results obtained are as follows: 1. Whole body CT examinations were performed on the patients of advanced age more frequently than on those of young age and performed most frequently on the group in the sixties. 2. The number of CT examinations performed on head and abdomen of the patients was 86.7% of a total of 2884 cases. 3. Enhanced CT examinations were perfomed on 26.1% of 2884 cases and most frequently on the group in the teens. 4. The percentage of the abnormal findings found in 2884 cases was 61.5% and this rate was higher than that shown in the reports made by us in 1980 and 1982, respectively. (author)

  15. Effects of whole-body γ-irradiation on the biosynthesis of certain serum proteins. Final report, November 29, 1967--June 30, 1976

    International Nuclear Information System (INIS)

    Neuhaus, O.W.

    1976-01-01

    Whole-body exposure of rats to ionizing radiations yielded an increased incorporation of labeled amino acids into serum albumin in in vivo studies suggesting a stimulation of biosynthesis. Actually this may have been caused by an elevated hepatic transport of labeled amino acids (see below). A suppressed biosynthesis of albumin was observed when the experiments were performed in vitro using liver microsomes. Impaired biosynthesis appeared to be caused by a reduced mRNA production. Irradiation stimulated the biosynthesis of acute-phase plasma proteins (stress response) and inhibited the excretion of α/sub 2u/-globulin, the sex-dependent protein of the adult male rat. Exposure of rats to γ-rays stimulated amino acid transport into the liver. This process which is Na + and energy-dependent was studied with α-aminoisobutyric acid, cycloleucine, and L-methionine among others. After irradiation the serum glucagon and insulin, as well as hepatic cAMP levels, were elevated. Amino acid transport may be an important factor in controlling the increased gluconeogenesis and glycogenesis observed in rats following whole-body irradiation

  16. A DXA Whole Body Composition Cross-Calibration Experience: Evaluation With Humans, Spine, and Whole Body Phantoms.

    Science.gov (United States)

    Krueger, Diane; Libber, Jessie; Sanfilippo, Jennifer; Yu, Hui Jing; Horvath, Blaine; Miller, Colin G; Binkley, Neil

    2016-01-01

    substantial lean and fat differences observed using BBCP and in vivo assessments. Consequently, spine phantoms are inadequate for dual-energy X-ray absorptiometry whole body composition cross-calibration. Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  17. Enhancement of syngeneic murine tumour transplantability by whole body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.

    1975-01-01

    Experiments were undertaken to test the general validity of the assumption that potentiation of tumour transplantability by sublethal whole body irradiation (WBI) implies some degree of immunological resistance in the intact host. A transplantable carcinoma of spontaneous origin in CBA mice which exhibits a large WBI effect was assayed quantitatively in mice which had been immunologically crippled in terms of allograft acceptance by depletion of thymus derived lymphocytes. The mean number of tumour cells required for 50% successful takes (TD 50 ) in these mice was found to be not significantly different from that in normal controls but highly significantly greater than in WBI mice. On the other hand, in mice which underwent laparotomy immediately before assay, the TD 50 was reduced significantly though not to the same extent as in WBI mice. It was concluded that WBI effect was not due to impaired host immunity but possibly to physiological changes resulting from acute stress. The hypothesis that hyperfibrinogenaemia which occurs after both WBI and laparotomy might increase tumour transplantability was rejected because of the lack of correlation between TD 50 and fibrinogen levels at different times after each procedure. From this and other work it is apparent that TD 50 data, in themselves, give no reliable indication of host immunity. (author)

  18. An experimental test on large animals of MCNP application for whole body counting

    International Nuclear Information System (INIS)

    Borisov, N.; Yatsenko, V.; Kochetkov, O.; Gusev, I.; Vlasov, P.; Kalistratova, V.; Nisimov, P.; Levochkin, F.; Borovkov, M.; Stolyarov, V.; Tsedish, S.; Tyurin, I.; Franck, D.; Carlan, L. de

    2005-01-01

    Measurements of actinide body burden using whole body counting spectrometry is hampered due to intensive absorption of γ-rays inside the patient's body, which depends on the anatomy of a patient. To establish the correspondence between pulse-height-spectra intensity and radionuclide activity, Monte Carlo calculations are widely used. For such calculations, the radiation transport geometry is usually described in terms of small rectangular boxes (voxels) retrieved from computed tomography or magnetic resonance images. The software for Monte Carlo-assisted calibration of whole body counting, which performs automatic creation of individual MCNP voxel phantoms, was checked in a quasi-in vivo experiment on large animals. During the experiment, pigs of 35-40 kg body mass were used as phantoms for measurement of actinides body burden. 241 Am was administered (via injection of a radioactive solution or via implantation of plastic capsules containing the radioactive material) into the lungs of pigs. The pigs were measured using the pure germanium low-energy γ-spectrometers. The images of animals were obtained using the computed tomography machine. On the base of these tomograms, MCNP4c2 calculations were done to obtain the pulse-height-spectra of the whole body counters. The experimental results were reproduced in calculations with error of less than 30% for 241 Am administered via injection and less than 10% for 241 Am administered inside the capsules. (authors)

  19. [Application of GVF snake model in segmentation of whole body bone SPECT image].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2008-02-01

    Limited by the imaging principle of whole body bone SPECT image, the gray value of bladder area is quite high, which affects the image's brightness, contrast and readability. In the meantime, the similarity between bladder area and focus makes it difficult for some images to be segmented automatically. In this paper, an improved Snake model, GVF Snake, is adopted to automatically segment bladder area, preparing for further processing of whole body bone SPECT images.

  20. Visuospatial memory computations during whole-body rotations in roll

    NARCIS (Netherlands)

    Pelt, S. van; Gisbergen, J.A.M. van; Medendorp, W.P.

    2005-01-01

    We used a memory-saccade task to test whether the location of a target, briefly presented before a whole-body rotation in roll, is stored in egocentric or in allocentric coordinates. To make this distinction, we exploited the fact that subjects, when tilted sideways in darkness, make systematic

  1. Computational modeling of blast induced whole-body injury: a review.

    Science.gov (United States)

    Chanda, Arnab; Callaway, Christian

    2018-02-01

    Blast injuries affect millions of lives across the globe due to its traumatic after effects on the brain and the whole body. To date, military grade armour materials are designed to mitigate ballistic and shrapnel attacks but are less effective in resisting blast impacts. In order to improve blast absorption characteristics of armours, the first key step is thoroughly understands the effects of blasts on the human body itself. In the last decade, a plethora of experimental and computational work has been carried out to investigate the mechanics and pathophysiology of Traumatic Brain Injury (TBI). However, very few attempts have been made so far to study the effect of blasts on the various other parts of the body such as the sensory organs (eyes and ears), nervous system, thorax, extremities, internal organs (such as the lungs) and the skeletal system. While an experimental evaluation of blast effects on such physiological systems is difficult, developing finite element (FE) models could allow the recreation of realistic blast scenarios on full scale human models and simulate the effects. The current article reviews the state-of-the-art in computational research in blast induced whole-body injury modelling, which would not only help in identifying the areas in which further research is required, but would also be indispensable for understanding body location specific armour design criteria for improved blast injury mitigation.

  2. Head Exposure to Cold during Whole-Body Cryostimulation: Influence on Thermal Response and Autonomic Modulation

    Science.gov (United States)

    Louis, Julien; Schaal, Karine; Bieuzen, François; Le Meur, Yann; Filliard, Jean-Robert; Volondat, Marielle; Brisswalter, Jeanick; Hausswirth, Christophe

    2015-01-01

    Recent research on whole-body cryotherapy has hypothesized a major responsibility of head cooling in the physiological changes classically reported after a cryostimulation session. The aim of this experiment was to verify this hypothesis by studying the influence of exposing the head to cold during whole-body cryostimulation sessions, on the thermal response and the autonomic nervous system (ANS). Over five consecutive days, two groups of 10 participants performed one whole-body cryostimulation session daily, in one of two different systems; one exposing the whole-body to cold (whole-body cryostimulation, WBC), and the other exposing the whole-body except the head (partial-body cryostimulation, PBC).10 participants constituted a control group (CON) not receiving any cryostimulation. In order to isolate the head-cooling effect on recorded variables, it was ensured that the WBC and PBC systems induced the same decrease in skin temperature for all body regions (mean decrease over the 5 exposures: -8.6°C±1.3°C and -8.3±0.7°C for WBC and PBC, respectively), which persisted up to 20-min after the sessions (P20). The WBC sessions caused an almost certain decrease in tympanic temperature from Pre to P20 (-0.28 ±0.11°C), while it only decreased at P20 (-0.14±0.05°C) after PBC sessions. Heart rate almost certainly decreased after PBC (-8.6%) and WBC (-12.3%) sessions. Resting vagal-related heart rate variability indices (the root-mean square difference of successive normal R-R intervals, RMSSD, and high frequency band, HF) were very likely to almost certainly increased after PBC (RMSSD:+49.1%, HF: +123.3%) and WBC (RMSSD: +38.8%, HF:+70.3%). Plasma norepinephrine concentration was likely increased in similar proportions after PBC and WBC, but only after the first session. Both cryostimulation techniques stimulated the ANS with a predominance of parasympathetic tone activation from the first to the fifth session and in slightly greater proportion with WBC than PBC

  3. Correlates of whole-blood polyunsaturated fatty acids among young children with moderate acute malnutrition

    DEFF Research Database (Denmark)

    Yaméogo, Charles W; Cichon, Bernardette; Fabiansen, Christian

    2017-01-01

    BACKGROUND: Severe acute malnutrition (SAM) has been associated with low polyunsaturated fatty acid (PUFA) status. However, investigations regarding PUFA status and correlates in children with moderate acute malnutrition (MAM) from low-income countries are scarce. The aim of this study...... was to describe whole-blood PUFA levels in children with moderate acute malnutrition (MAM) and to identify correlates of PUFAs. METHODS: We conducted a cross-sectional study using baseline data from a prospective nutritional intervention trial among 1609 children with MAM aged 6-23 months in Burkina Faso...

  4. Effects of whole-body and partial-body x irradiation upon epidermal mitotic activity during wound healing in mouse skin

    International Nuclear Information System (INIS)

    Kobayashi, K.

    1977-01-01

    Mitotic activity of normal (unwounded) and wounded skin was measured in the control (nonirradiated) and whole-body or partial-body x-irradiated mouse. Higher mitotic activity in the anterior than in the posterior region of the body was found in both the normal and the wounded skin of the control mouse. Whole-body irradiation (500 R) depressed completely the mitotic activity of normal skin 2 to 4 days after irradiation. In spite of this depression in mitotic activity, a surgical incision made 1 to 3 days after irradiation could induce a burst of proliferation after an inhibition of an initial mitosis increase. When the animals were partially irradiated with 500 R 3 days before wounding, it was shown that mitosis at 24 hr after wounding was inhibited markedly by the local effect of irradiation and that mitosis also could be inhibited diversely by the abscopal effect of irradiation. Because of a close similarity of sequential mitotic patterns between whole-body-irradiated and flapped-skin-only-irradiated groups (direct irradiation), the effect of irradiation upon mitosis was considered to be primarily local. Some discussions were made concerning the possible reasons which made a difference in mitotic patterns between the head-only-irradiated group, the irradiated group including the head and other parts of the body except for the skin flap

  5. Evaluation of whole-body MR to CT deformable image registration.

    Science.gov (United States)

    Akbarzadeh, A; Gutierrez, D; Baskin, A; Ay, M R; Ahmadian, A; Riahi Alam, N; Lövblad, K O; Zaidi, H

    2013-07-08

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based on B-spline transformation was performed using optimized parameters of the elastix package based on the Insight Toolkit (ITK) framework. Twenty-eight (17 male and 11 female) clinical studies were used in this work. The registration was evaluated using anatomical landmarks and segmented organs. In addition to 16 anatomical landmarks, three key organs (brain, lungs, and kidneys) and the entire body volume were segmented for evaluation. Several parameters--such as the Euclidean distance between anatomical landmarks, target overlap, Dice and Jaccard coefficients, false positives and false negatives, volume similarity, distance error, and Hausdorff distance--were calculated to quantify the quality of the registration algorithm. Dice coefficients for the majority of patients (> 75%) were in the 0.8-1 range for the whole body, brain, and lungs, which satisfies the criteria to achieve excellent alignment. On the other hand, for kidneys, Dice coefficients for volumes of 25% of the patients meet excellent volume agreement requirement, while the majority of patients satisfy good agreement criteria (> 0.6). For all patients, the distance error was in 0-10 mm range for all segmented organs. In summary, we optimized and evaluated the accuracy of an MR to CT deformable registration algorithm. The registered images constitute a useful 3D whole-body MR-CT atlas suitable for the development and evaluation of novel MR-guided attenuation correction procedures on hybrid PET-MR systems.

  6. Whole-body cryostimulation increases parasympathetic outflow and decreases core body temperature.

    Science.gov (United States)

    Zalewski, Pawel; Bitner, Anna; Słomko, Joanna; Szrajda, Justyna; Klawe, Jacek J; Tafil-Klawe, Malgorzata; Newton, Julia L

    2014-10-01

    The cardiovascular, autonomic and thermal response to whole-body cryostimulation exposure are not completely known. Thus the aim of this study was to evaluate objectively and noninvasively autonomic and thermal reactions observed after short exposure to very low temperatures. We examined 25 healthy men with mean age 30.1 ± 3.7 years and comparable anthropomorphical characteristic. Each subject was exposed to cryotherapeutic temperatures in a cryogenic chamber for 3 min (approx. -120 °C). The cardiovascular and autonomic parameters were measured noninvasively with Task Force Monitor. The changes in core body temperature were determined with the Vital Sense telemetric measurement system. Results show that 3 min to cryotherapeutic temperatures causes significant changes in autonomic balance which are induced by peripheral and central blood volume changes. Cryostimulation also induced changes in core body temperature, maximum drop of core temperature was observed 50-60 min after the stimulation. Autonomic and thermal reactions to cryostimulation were observed up to 6 h after the exposure and were not harmful for examined subjects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  8. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  9. Whole-body MR angiography with body coil acquisition at 3 T in patients with peripheral arterial disease using the contrast agent gadofosveset trisodium

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Eiberg, Jonas P; Løgager, Vibeke B

    2009-01-01

    Whole-body magnetic resonance angiography (WB-MRA) at 3 T with body coil acquisition has not previously been investigated. In this study, WB-MRA was performed in this manner using the blood pool contrast agent gadofosveset trisodium.......Whole-body magnetic resonance angiography (WB-MRA) at 3 T with body coil acquisition has not previously been investigated. In this study, WB-MRA was performed in this manner using the blood pool contrast agent gadofosveset trisodium....

  10. Force direction patterns promote whole body stability even in hip-flexed walking, but not upper body stability in human upright walking

    Science.gov (United States)

    Müller, Roy; Rode, Christian; Aminiaghdam, Soran; Vielemeyer, Johanna; Blickhan, Reinhard

    2017-11-01

    Directing the ground reaction forces to a focal point above the centre of mass of the whole body promotes whole body stability in human and animal gaits similar to a physical pendulum. Here we show that this is the case in human hip-flexed walking as well. For all upper body orientations (upright, 25°, 50°, maximum), the focal point was well above the centre of mass of the whole body, suggesting its general relevance for walking. Deviations of the forces' lines of action from the focal point increased with upper body inclination from 25 to 43 mm root mean square deviation (RMSD). With respect to the upper body in upright gait, the resulting force also passed near a focal point (17 mm RMSD between the net forces' lines of action and focal point), but this point was 18 cm below its centre of mass. While this behaviour mimics an unstable inverted pendulum, it leads to resulting torques of alternating sign in accordance with periodic upper body motion and probably provides for low metabolic cost of upright gait by keeping hip torques small. Stabilization of the upper body is a consequence of other mechanisms, e.g. hip reflexes or muscle preflexes.

  11. Morphological studies on the healing process of tooth extraction wounds in whole body irradiated rats

    International Nuclear Information System (INIS)

    Hosokawa, Yoichiro

    1991-01-01

    The present studies were performed to investigate the healing process of the tooth extraction wound in whole body irradiated rats and to clarify the effect of irradiation on bone metabolism. One hundred and seven Wistar rats of about 100 g body weight were used and divided into 3 groups. Whole body irradiated rats were given single exposure with a dose of 8 Gy. The region of the left upper molars of local irradiated rats as controls, was exposed to 8 Gy. On the 7th day after irradiation, the left upper first molar of each rat was extracted. The rats were sacrificed at intervals of 1 to 14 days after extraction. Non-irradiated rats were sacrificed at the same intervals after extraction. The maxillary bone including the extraction wound was evaluated, histologically, histometrically and ultrastructurally. From the histological and histometrical findings, the difference of the healing process between non-irradiated rats and locally irradiated rats is not significant. In whole body irradiated rats, the healing process especially in the socket was disturbed. The osteoblastic new bone formation following production of granulation tissue was interfered with. Ultrastructurally, the cytoplasmic organellae were poorly developed in the osteoblast and osteoid formation was reduced in the socket. But periosteal new bone formation was the same as that of the locally irradiated rats. In whole body irradiated rats, the osteoclasts in the interradicular alveolar bone were decreased and have smaller nuclei, compared with non-irradiated and locally irradiated rats. Histometrically, the amount of bone loss was decreased in whole body irradiated rats. Ultrastructurally, the cyoplasmic organellae and ruffled border were poorly developed in the osteoclasts of whole body irradiated rats. The findings suggested that irradiation induced cytological changes not only in osteoblasts but in osteoclasts and these changes resulted in the delayed healing of extraction wound. (author) 106 refs

  12. Morphological studies on the healing process of tooth extraction wounds in whole body irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Yoichiro (Hokkaido Univ., Sapporo (Japan). School of Dentistry)

    1991-06-01

    The present studies were performed to investigate the healing process of the tooth extraction wound in whole body irradiated rats and to clarify the effect of irradiation on bone metabolism. One hundred and seven Wistar rats of about 100 g body weight were used and divided into 3 groups. Whole body irradiated rats were given single exposure with a dose of 8 Gy. The region of the left upper molars of local irradiated rats as controls, was exposed to 8 Gy. On the 7th day after irradiation, the left upper first molar of each rat was extracted. The rats were sacrificed at intervals of 1 to 14 days after extraction. Non-irradiated rats were sacrificed at the same intervals after extraction. The maxillary bone including the extraction wound was evaluated, histologically, histometrically and ultrastructurally. From the histological and histometrical findings, the difference of the healing process between non-irradiated rats and locally irradiated rats is not significant. In whole body irradiated rats, the healing process especially in the socket was disturbed. The osteoblastic new bone formation following production of granulation tissue was interfered with. Ultrastructurally, the cytoplasmic organellae were poorly developed in the osteoblast and osteoid formation was reduced in the socket. But periosteal new bone formation was the same as that of the locally irradiated rats. In whole body irradiated rats, the osteoclasts in the interradicular alveolar bone were decreased and have smaller nuclei, compared with non-irradiated and locally irradiated rats. Histometrically, the amount of bone loss was decreased in whole body irradiated rats. Ultrastructurally, the cyoplasmic organellae and ruffled border were poorly developed in the osteoclasts of whole body irradiated rats. The findings suggested that irradiation induced cytological changes not only in osteoblasts but in osteoclasts and these changes resulted in the delayed healing of extraction wound. (author) 106 refs.

  13. Whole body vibration improves attention and motor performance in ...

    African Journals Online (AJOL)

    Background: Whole body vibration (WBV) is a form of physical stimulation via mechanical vibrations transmitted to a subject. It is assumed that WBV induces sensory stimulation in cortical brain regions through the activation of skin and muscle receptors responding to the vibration. The effects of WBV on muscle strength are ...

  14. Radiation induced late delayed alterations in mice brain after whole body and cranial radiation: a comparative DTI analysis

    International Nuclear Information System (INIS)

    Watve, Apurva; Gupta, Mamta; Trivedi, Richa; Khushu, Subash; Rana, Poonam

    2016-01-01

    Moderate dose of radiation exposure occurs during radiation accidents or radiation therapy induces pathophysiological alterations in CNS that may persist for longer duration. Studies suggest that late delayed injury is irreversible leading to metabolic and cognitive impairment. Our earlier studies have illustrated the varied response of brain at acute and early delayed phase on exposure to cranial and whole body radiation. Hence in continuation with our previous studies, present study focuses on comparative microstructural changes in brain at late delayed phase of radiation injury using Diffusion Tensor Imaging (DTI) technique. Region of interest (ROIs) were drawn on corpus callosum (CC), hippocampus (HIP), sensory-motor cortex (SMC), thalamus (TH), hypothalamus (HTH), cingulum (CG), caudeto-putamen (CUP) and cerebral peduncle (CP). The differences in FA (Fractional Anisotropy) and MD (Mean Diffusivity) values generated from these regions of all the groups were evaluated by ANOVA with multiple comparisons using Bonferroni, Post Hoc test. Maximum changes have been observed in MD values mainly in cranial group showing significantly increased MD in CC and SMC region while both the groups showed changes in TH and CUP region as compared to control. FA showed more prominent changes in whole body radiation group than cranial group by decreasing significantly in CP region while in HTH and CUP region in both the groups. Reduced FA indicates compromised structural integrity due to the loss of glial progenitor cells causing transient demyelination while increased MD has been equated with cellular membrane disruption, cell death and vasogenic edema. Thus, present study reveals late delayed CNS response after cranial and whole body radiation exposure. These findings can help us differentiate and monitor the pathophysiological changes at later stages either due to accidental or intentional exposure to ionizing radiation

  15. Bases for calibration of whole body counters using anthropomorphic physical simulators

    International Nuclear Information System (INIS)

    Dantas, Bernardo Maranhao

    1998-01-01

    The quantification of radionuclides in the human body can be carried out through in vivo measurements performed in facilities generically called whole body counters. The calibration of such units is usually done by using physical anthropomorphic phantoms, which can be defined as artificial structures with geometrical characteristics and attenuation properties similar to the living tissues. This work presents the development of the phantoms necessary to the monitoring of the internal contamination by the radionuclides manipulated in Brazil. It also presents the procedures for the calibration of the detectors used for the in vivo measurements. The developed phantoms are applied in the determination of radionuclides deposited in specific organs, such as Th-232 and Am-241 in the lungs and skull, isotopes of iodine in the thyroid and photon emitters in the energy range from 100 to 3000 keV in the whole body. (author)

  16. Revisiting the Body-Schema Concept in the Context of Whole-Body Postural-Focal Dynamics

    Science.gov (United States)

    Morasso, Pietro; Casadio, Maura; Mohan, Vishwanathan; Rea, Francesco; Zenzeri, Jacopo

    2015-01-01

    The body-schema concept is revisited in the context of embodied cognition, further developing the theory formulated by Marc Jeannerod that the motor system is part of a simulation network related to action, whose function is not only to shape the motor system for preparing an action (either overt or covert) but also to provide the self with information on the feasibility and the meaning of potential actions. The proposed computational formulation is based on a dynamical system approach, which is linked to an extension of the equilibrium-point hypothesis, called Passive Motor Paradigm: this dynamical system generates goal-oriented, spatio-temporal, sensorimotor patterns, integrating a direct and inverse internal model in a multi-referential framework. The purpose of such computational model is to operate at the same time as a general synergy formation machinery for planning whole-body actions in humanoid robots and/or for predicting coordinated sensory–motor patterns in human movements. In order to illustrate the computational approach, the integration of simultaneous, even partially conflicting tasks will be analyzed in some detail with regard to postural-focal dynamics, which can be defined as the fusion of a focal task, namely reaching a target with the whole-body, and a postural task, namely maintaining overall stability. PMID:25741274

  17. Revisiting the body-schema concept in the context of whole-body postural-focal dynamics.

    Science.gov (United States)

    Morasso, Pietro; Casadio, Maura; Mohan, Vishwanathan; Rea, Francesco; Zenzeri, Jacopo

    2015-01-01

    The body-schema concept is revisited in the context of embodied cognition, further developing the theory formulated by Marc Jeannerod that the motor system is part of a simulation network related to action, whose function is not only to shape the motor system for preparing an action (either overt or covert) but also to provide the self with information on the feasibility and the meaning of potential actions. The proposed computational formulation is based on a dynamical system approach, which is linked to an extension of the equilibrium-point hypothesis, called Passive Motor Paradigm: this dynamical system generates goal-oriented, spatio-temporal, sensorimotor patterns, integrating a direct and inverse internal model in a multi-referential framework. The purpose of such computational model is to operate at the same time as a general synergy formation machinery for planning whole-body actions in humanoid robots and/or for predicting coordinated sensory-motor patterns in human movements. In order to illustrate the computational approach, the integration of simultaneous, even partially conflicting tasks will be analyzed in some detail with regard to postural-focal dynamics, which can be defined as the fusion of a focal task, namely reaching a target with the whole-body, and a postural task, namely maintaining overall stability.

  18. Revisiting the body-schema concept in the context of Whole-Body Postural-Focal Dynamics

    Directory of Open Access Journals (Sweden)

    Pietro eMorasso

    2015-02-01

    Full Text Available The body schema concept is revisited in the context of embodied cognition, further developing the theory formulated by Marc Jeannerod that the motor system is part of a simulation network related to action, whose function is not only to shape the motor system for preparing an action (either overt or covert, but also to provide the self with information on the feasibility and the meaning of potential actions. The proposed computational formulation is based on a dynamical system approach, which is linked to an extension of the Equilibrium Point Hypothesis, called Passive Motor Paradigm: this dynamical system generates goal-oriented, spatio-temporal, sensorimotor patterns, integrating a direct and inverse internal model in a multi-referential framework. The purpose of such computational model is to operate at the same time as a general synergy formation machinery for planning whole-body actions in humanoid robots and/or for predicting coordinated sensory-motor patterns in human movements. In order to illustrate the computational approach, the integration of simultaneous, even partially conflicting tasks will be analyzed in some detail with regard to postural-focal dynamics, which can be defined as the fusion of a focal task, namely reaching a target with the whole-body, and a postural task, namely maintaining overall stability.

  19. Study of food intake dynamics in rats following acute whole-body irradiation with X rays

    International Nuclear Information System (INIS)

    Smajda, B.; Ahlers, I.; Datelinka, I.

    1987-01-01

    The effects were studied of whole-body X-irradiation with sublethal (2.39 Gy) and medium lethal (5.74 Gy) doses on food intake by rats. The lower dose caused a temporary decrease in food intake, with a minimum of 63.3% of the control level on the 2nd day after irradiation. The decrease was statistically significant up to the 4th day after irradiation. No substantial changes were observed in the parameters of the circadian rhythm in food intake with the maximum on the 3rd day after irradiation, with only 8% of the initial value. The food intake was reduced until the 9th day after irradiation. The daily thythm of food intake was strongly disturbed during the first three days after irradiation, then restoring gradually and on the 9th day showing the original phasing and shape. The results obtained were in agreement with the assumed neural regulation mechanism of food intake and its circadian rhythm in the rat. (author). 5 figs., 12 refs

  20. Scanning personnel for internal deposition of radioactive material with personnel contamination whole body friskers and portal monitors

    International Nuclear Information System (INIS)

    Lobdell, J.L.

    1996-01-01

    The potential for using personnel contamination devices such as whole body friskers and portal monitors for internal contamination monitoring was evaluated. Internally deposited radioactive material is typically determined with whole body counting systems. Whole body counts have traditionally been performed on personnel when they report for work, on a periodic basis (i.e., annually), when an uptake is suspected, and on termination. These counts incur significant expense. The monitored personnel pass through whole body friskers and portal monitors daily. This investigation was performed to determine if the external contamination monitors could provide an alternative to the more Costly whole body counting. The ability to detect 1% of a DAC for critical radioisotopes was applied as a detection criteria for this investigation. The results of whole body counts were used to identify the typical internal contamination radionuclides. From this list, the radioisotopes that would be the most difficult to measure were identified. From this review, 60 Co and 131 I were determined to be the critical radionuclides. One percent of a DAC for each isotope was placed, one at a time, in a humanoid phantom. The phantom was placed in the whole body frisker and open-quotes countedclose quotes. The phantom was carried through the portal monitor at a speed equivalent to a person walking through the monitor. Frequency of detection was derived for both systems. Practical aspects of integrating this screening system with traditional internal dosimetry programs are discussed

  1. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  2. Whole body dual X-ray absorptiometry for bone mineral density and body composition using a flat panel detector

    International Nuclear Information System (INIS)

    Dinten, J.M.; Robert-Coutant, C.; Gonon, G.; Bordy, T.

    2003-01-01

    Whole-body dual-energy X-ray absorptiometry (DXA) systems are used for the determination of bone mineral density (BMD) but also for body composition estimates (lean mass and fat mass). The calculation is based on the difference in attenuation of body tissues for a low-energy of about 50 KeV and a high-energy of about 80-100 KeV. The measurement of dual-energy projections allows first to compute to the body composition in the non-bone area, and then to extrapolate the fat / lean ratio of soft tissue into the bone area in order to compute the BMD. Since detectors have limited area, a whole body examination requires a scan of the patient and a reconstruction process in order to build up a large field image from smaller radiographs. This reconstruction process must keep the quantitative value of the radiographs, and avoid any distortion which could be a consequence of the conic acquisition geometry. The cone angle is low (6 at maximum) and the large overlap between radiographs helps to reconstruct an image equivalent with a parallel-beam geometry. Scatter is corrected from the radiographs before reconstruction, as described in a previous paper ('Dual-energy X-rays absorptiometry using a 2D digital radiography detector. Application to bone densitometry', SPIE Medical Imaging 2001, Medical Physics). We have developed an original reconstruction method dedicated to whole-body examinations which will be described. Thanks to the quasi-radiologic quality of the detector, reconstructed images are of very good quality and this makes the measurement of BMD and fat / lean masses easier. (author)

  3. Alleviation of Motor Impairments in Patients with Cerebral Palsy: Acute Effects of Whole-body Vibration on Stretch Reflex Response, Voluntary Muscle Activation and Mobility

    Directory of Open Access Journals (Sweden)

    Anne Krause

    2017-08-01

    Full Text Available IntroductionIndividuals suffering from cerebral palsy (CP often have involuntary, reflex-evoked muscle activity resulting in spastic hyperreflexia. Whole-body vibration (WBV has been demonstrated to reduce reflex activity in healthy subjects, but evidence in CP patients is still limited. Therefore, this study aimed to establish the acute neuromuscular and kinematic effects of WBV in subjects with spastic CP.Methods44 children with spastic CP were tested on neuromuscular activation and kinematics before and immediately after a 1-min bout of WBV (16–25 Hz, 1.5–3 mm. Assessment included (1 recordings of stretch reflex (SR activity of the triceps surae, (2 electromyography (EMG measurements of maximal voluntary muscle activation of lower limb muscles, and (3 neuromuscular activation during active range of motion (aROM. We recorded EMG of m. soleus (SOL, m. gastrocnemius medialis (GM, m. tibialis anterior, m. vastus medialis, m. rectus femoris, and m. biceps femoris. Angular excursion was recorded by goniometry of the ankle and knee joint.ResultsAfter WBV, (1 SOL SRs were decreased (p < 0.01 while (2 maximal voluntary activation (p < 0.05 and (3 angular excursion in the knee joint (p < 0.01 were significantly increased. No changes could be observed for GM SR amplitudes or ankle joint excursion. Neuromuscular coordination expressed by greater agonist–antagonist ratios during aROM was significantly enhanced (p < 0.05.DiscussionThe findings point toward acute neuromuscular and kinematic effects following one bout of WBV. Protocols demonstrate that pathological reflex responses are reduced (spinal level, while the execution of voluntary movement (supraspinal level is improved in regards to kinematic and neuromuscular control. This facilitation of muscle and joint control is probably due to a reduction of spasticity-associated spinal excitability in favor of giving access for greater supraspinal input during voluntary motor

  4. High-resolution gamma spectroscopy with whole-body and partial-body counters. Experience, recommendations. Report

    International Nuclear Information System (INIS)

    Sahre, P.

    1997-12-01

    The application of high-resolution gamma spectroscopy with whole-body and partial-body counters shows a steadily rising upward trend over the last few years. This induced the ''Arbeitskreis Inkorporationsueberwachung'' of the association ''Fachverband fuer Strahlenschutz e.V.'' to organise a meeting for joint elaboration of a guide on recommended applications of this measuring technique, based on a review of existing experience and results. A key item on the agenda of the meeting was the comparative evaluation of the Ge semiconductor detector and the NaI solid scintillation detector. (orig./CB) [de

  5. Optimized workflow and imaging protocols for whole-body oncologic PET/MRI.

    Science.gov (United States)

    Ishii, Shirou; Hara, Takamitsu; Nanbu, Takeyuki; Suenaga, Hiroki; Sugawara, Shigeyasu; Kuroiwa, Daichi; Sekino, Hirofumi; Miyajima, Masayuki; Kubo, Hitoshi; Oriuchi, Noboru; Ito, Hiroshi

    2016-11-01

    Although PET/MRI has the advantages of a simultaneous acquisition of PET and MRI, high soft-tissue contrast of the MRI images, and reduction of radiation exposure, its low profitability and long acquisition time are significant problems in clinical settings. Thus, MRI protocols that meet oncological purposes need to be used in order to reduce examination time while securing detectability. Currently, half-Fourier acquisition single-shot turbo spin echo and 3D-T1 volumetric interpolated breath-hold examination may be the most commonly used sequences for whole-body imaging due to their shorter acquisition time and higher diagnostic accuracy. Although there have been several reports that adding diffusion weighted image (DWI) to PET/MRI protocol has had no effect on tumor detection to date, in cases of liver, kidney, bladder, and prostate cancer, the use of DWI may be beneficial in detecting lesions. Another possible option is to scan each region with different MRI sequences instead of scanning the whole body using one sequence continuously. We herein report a workflow and imaging protocols for whole-body oncologic PET/MRI using an integrated system in the clinical routine, designed for the detection, for example by cancer screening, of metastatic lesions, in order to help future users optimize their workflow and imaging protocols.

  6. Wireless Cortical Brain-Machine Interface for Whole-Body Navigation in Primates

    Science.gov (United States)

    Rajangam, Sankaranarayani; Tseng, Po-He; Yin, Allen; Lehew, Gary; Schwarz, David; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.

    2016-03-01

    Several groups have developed brain-machine-interfaces (BMIs) that allow primates to use cortical activity to control artificial limbs. Yet, it remains unknown whether cortical ensembles could represent the kinematics of whole-body navigation and be used to operate a BMI that moves a wheelchair continuously in space. Here we show that rhesus monkeys can learn to navigate a robotic wheelchair, using their cortical activity as the main control signal. Two monkeys were chronically implanted with multichannel microelectrode arrays that allowed wireless recordings from ensembles of premotor and sensorimotor cortical neurons. Initially, while monkeys remained seated in the robotic wheelchair, passive navigation was employed to train a linear decoder to extract 2D wheelchair kinematics from cortical activity. Next, monkeys employed the wireless BMI to translate their cortical activity into the robotic wheelchair’s translational and rotational velocities. Over time, monkeys improved their ability to navigate the wheelchair toward the location of a grape reward. The navigation was enacted by populations of cortical neurons tuned to whole-body displacement. During practice with the apparatus, we also noticed the presence of a cortical representation of the distance to reward location. These results demonstrate that intracranial BMIs could restore whole-body mobility to severely paralyzed patients in the future.

  7. Improved quality of image got through whole-body CT scanner

    International Nuclear Information System (INIS)

    Asahina, Kiyotaka

    1980-01-01

    The quality of brain images taken with a whole-body CT scanner has so far been generally inferior in quality to those got through a CT scanner exclusively used for brains. In order to improve the whole-body CT scanner so as to get better brain image, its detection system has been made multichannel; the capacity of its X-ray tube, increased; and its software, innovated. As a result, the spatial resolution has been improved from 5.51 p/cm to 9.01 p/cm, the contrast resolution has been improved from 3.2 mm% to 1.5 mm%, with the noise maintained at 0.5%. In clinical examination, the image quality has been improved equally well for brains, abdomens and lungs. Especially high appreciation is given to the diagnosis information got through this new scanner. (author)

  8. Retrospective Evaluation of Whole Body Computed Tomography for Tumor Staging in Dogs with Primary Appendicular Osteosarcoma.

    Science.gov (United States)

    Talbott, Jessica L; Boston, Sarah E; Milner, Rowan J; Lejeune, Amandine; Souza, Carlos H de M; Kow, Kelvin; Bacon, Nicholas J; Hernandez, Jorge A

    2017-01-01

    To evaluate whole body computed tomography (CT) for staging canine appendicular osteosarcoma. Retrospective case series. Client-owned dogs diagnosed with appendicular osteosarcoma (n=39). Medical records for client-owned dogs diagnosed with appendicular osteosarcoma from August 2008 to July 2014 were reviewed. Dogs were included if they had a confirmed diagnosis of appendicular osteosarcoma and were staged using whole body CT. Data collected included signalment, body weight, primary tumor location, serum alkaline phosphatase (ALP) activity, findings on 3-view thoracic radiographs, cytologic or histologic results, and findings on CT. Thirty-nine dogs (median age 8.5 years; median body weight 37 kg) had osteosarcoma of the distal radius (n=17), proximal humerus (11) and other sites. Serum ALP activity was elevated in 14 dogs. Bone metastasis was not detected in any dog on whole body CT. Pulmonary metastasis was considered definitive on CT based on board certified radiologist assessment in 2/39 dogs (5%). Two additional dogs (2/39, 5%) had soft tissue masses diagnosed on CT, consistent with concurrent, non-metastatic malignancies. Bone metastases were not identified in any dog with whole body CT. Thoracic and abdominal CT detected lung lesions and concurrent neoplasia in dogs with primary appendicular osteosarcoma. Whole body CT may be a useful adjunct to other screening tests for disseminated malignancy. © 2016 The American College of Veterinary Surgeons.

  9. Calibration of the whole body counter at PSI

    International Nuclear Information System (INIS)

    Mayer, Sabine; Boschung, Markus; Fiechtner, Annette; Habegger, Ruedi; Meier, Kilian; Wernli, Christian

    2008-01-01

    At the Paul Scherrer Institut (PSI), measurements with the whole body counter are routinely carried out for occupationally exposed persons and occasionally for individuals of the population suspected of radioactive intake. In total about 400 measurements are performed per year. The whole body counter is based on a p-type high purity germanium (HPGe) coaxial detector mounted above a canvas chair in a shielded small room. The detector is used to detect the presence of radionuclides that emit photons with energies between 50 keV and 2 MeV. The room itself is made of iron from old railway rails to reduce the natural background radiation to 24 n Sv/h. The present paper describes the calibration of the system with the IGOR phantom. Different body sizes are realized by different standardized configurations of polyethylene bricks, in which small tubes of calibration sources can be introduced. The efficiency of the detector was determined for four phantom geometries (P1, P2, P4 and P6 simulating human bodies in sitting position of 12 kg, 24 kg, 70 kg and 110 kg, respectively. The measurements were performed serially using five different radionuclide sources ( 40 K, 60 Co, 133 Ba, 137 Cs, 152 Eu) within the phantom bricks. Based on results of the experiment, an efficiency curve for each configuration and the detection limits for relevant radionuclides were determined. For routine measurements, the efficiency curve obtained with the phantom geometry P4 was chosen. The detection limits range from 40 Bq to 1000 Bq for selected radionuclides applying a measurement time of 7 min. The proper calibration of the system, on one hand, is essential for the routine measurements at PSI. On the other hand, it serves as a benchmark for the already initiated characterisation of the system with Monte Carlo simulations. (author)

  10. Effects of Whole-Body Vibration Therapy in Patients with Fibromyalgia: A Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Daniel Collado-Mateo

    2015-01-01

    Full Text Available Objective. To review the literature on the effects of whole-body vibration therapy in patients with fibromyalgia. Design. Systematic literature review. Patients. Patients with fibromyalgia. Methods. An electronic search of the literature in four medical databases was performed to identify studies on whole-body vibration therapy that were published up to the 15th of January 2015. Results. Eight articles satisfied the inclusion and exclusion criteria and were analysed. According to the Dutch CBO guidelines, all selected trials had a B level of evidence. The main outcomes that were measured were balance, fatigue, disability index, health-related quality of life, and pain. Whole-body vibration appeared to improve the outcomes, especially balance and disability index. Conclusion. Whole-body vibration could be an adequate treatment for fibromyalgia as a main therapy or added to a physical exercise programme as it could improve balance, disability index, health-related quality of life, fatigue, and pain. However, this conclusion must be treated with caution because the paucity of trials and the marked differences between existing trials in terms of protocol, intervention, and measurement tools hampered the comparison of the trials.

  11. In-vivo assessment of whole-body radioisotope burdens at the Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Vasilik, D.G.; Aikin, I.C.

    1983-08-01

    The Los Alamos National Laboratory program for in-vivo measurements includes the capability for the whole-body assessment of body burdens for x-ray or gamma-ray emitting radioisotopes. This capability is an important part of the health and safety program at Los Alamos where a wide variety of radioisotopes are utilized. This report addresses the whole body portion of our in-vivo measurement capabilities. Whole-body measurements at Los Alamos make use of a hyperpure germanium (HpGe) detector and a lithium-drifted germanium [Ge(Li)] detector for identification and quantification of radioisotopes. Analysis results are interpreted in terms of two basic statistical measures of detection limits. One measure is called the minimum significant measured activity (MSMA), which is interpreted as meaning that there is some activity in the body. The second measure is called the minimum detectable true activity (MDTA), which is defined as the smallest amount of activity required to be in the body in order that a measurement of an individual can be expected to imply correctly the presence of activity with a predetermined degree of confidence. 7 references, 8 figures

  12. A simple calibration of a whole-body counter for the measurement of total body potassium in humans

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; El-Enany, N.; Youssef, S.K.; Aly, A.M.; Abbas, M.T.

    1992-01-01

    A simple calibration procedure for the Inshas whole body counter for evaluating total body potassium has been adopted. More than 120 Egyptian employees in the Nuclear Research Center (N.R.C.) were studied for their total body potassium (TBK). The potassium values were found to have an average of 2.85±0.57 g K kg -1 body weight for males and 2.62±0.52 g K kg -1 for females, which are higher than the recommended value given for reference man by ICRP. The TBK varied directly with body build index and is slightly sex dependent (Author)

  13. Effect of whole-body vibration on muscle strength, spasticity, and ...

    African Journals Online (AJOL)

    CP) and is characterized by spasticity and muscle weakness of both lower limbs resulting in decreased walking ability. The purpose of this study was to evaluate the effect of whole body vibration (WBV) training on muscle strength, spasticity, and ...

  14. Calculation of effective dose in whole body in dependence of angle of collimator for photon fields

    International Nuclear Information System (INIS)

    Fuenzalida, M.; Varon, C.; Piriz, G.; Banguero, Y.; Lozano, E.; Mancilla, C.

    2011-01-01

    The objective of this work is to obtain quantifiable data of whole body effective dose for photons fields of 6 MV and 18 MV in function of the collimator angle of a Varian Clinac 21EX lineal accelerator. It has been made a variety of studies which investigate the form to reduce the dose in whole body with photons fields, specially over the potential risks and the influence of the collimator angle, as performed Stanthakis et al. [1] with the Monte Carlo method. As a result of this work, the values of whole body effective doses are higher with a 0 deg collimator than with a 90 deg collimator, and as the field size increases, the effective doses difference in whole body, between 0 deg and 90 deg collimator angle, for both energies, becomes smaller. (author)

  15. Calculation of effective dose in whole body in dependence of angle of collimator for photon fields

    Energy Technology Data Exchange (ETDEWEB)

    Fuenzalida, M. [Universidad de la Frontera, Temuco (Chile). Programa de Magister en Fisica Medica; Varon, C.; Piriz, G.; Banguero, Y.; Lozano, E.; Mancilla, C., E-mail: fisicamedica@incancer.c [Instituto Nacional del Cancer, Santiago (Chile). Unidad de Fisica Medica

    2011-07-01

    The objective of this work is to obtain quantifiable data of whole body effective dose for photons fields of 6 MV and 18 MV in function of the collimator angle of a Varian Clinac 21EX lineal accelerator. It has been made a variety of studies which investigate the form to reduce the dose in whole body with photons fields, specially over the potential risks and the influence of the collimator angle, as performed Stanthakis et al. [1] with the Monte Carlo method. As a result of this work, the values of whole body effective doses are higher with a 0 deg collimator than with a 90 deg collimator, and as the field size increases, the effective doses difference in whole body, between 0 deg and 90 deg collimator angle, for both energies, becomes smaller. (author)

  16. Distortion of calculated whole-body hematocrit during lower-body immersion in water.

    Science.gov (United States)

    Knight, D R; Santoro, T; Bondi, K R

    1986-11-01

    We found a difference between the venous hematocrits of immersed and nonimmersed arms during immersion of the lower body in cold water but not during a comparable exposure to warm water. Fourteen healthy men were exposed to three different experimental conditions: arm immersion, body immersion, and control. The men always sat upright while both upper extremities hung vertically at their sides. During arm immersion, one forearm was completely immersed for 30 min in either cold water (28 degrees C, n = 7) or warm water (38 degrees C, n = 7). This cold-warm water protocol was repeated on separate days for exposure to the remaining conditions of body immersion (immersion of 1 forearm and all tissues below the xiphoid process) and control (no immersion). Blood samples were simultaneously drawn from cannulated veins in both antecubital fossae. Hematocrit difference (Hct diff) was measured by subtracting the nonimmersed forearm's hematocrit (Hct dry) from the immersed forearm's hematocrit (Hct wet). Hct diff was approximately zero when the men were exposed to the control condition and body immersion in warm water. In the remaining conditions, Hct wet dropped below Hct dry (P less than 0.01, 3-way analysis of variance). The decrements of Hct diff showed there were differences between venous hematocrits in immersed and nonimmersed regions of the body, indicating that changes of the whole-body hematocrit cannot be calculated from a large-vessel hematocrit soon after immersing the lower body in cold water.

  17. Development of an Ergonomics Checklist for Investigation of Work-Related Whole-Body Disorders in Farming - AWBA: Agricultural Whole-Body Assessment.

    Science.gov (United States)

    Kong, Y K; Lee, S J; Lee, K S; Kim, G R; Kim, D M

    2015-10-01

    Researchers have been using various ergonomic tools to study occupational musculoskeletal diseases in industrial contexts. However, in agricultural work, where the work environment is poorer and the socio-psychological stress is high due to the high labor intensities of the industry, current research efforts have been scarce, and the number of available tools is small. In our preliminary studies, which focused on a limited number of body parts and other working elements, we developed separate evaluation tools for the upper and lower extremities. The current study was conducted to develop a whole-body ergonomic assessment tool for agricultural work that integrates the existing assessment tools for lower and upper extremities developed in the preliminary studies and to verify the relevance of the integrated assessment tool. To verify the relevance of the Agricultural Whole-Body Assessment (AWBA) tool, we selected 50 different postures that occur frequently in agricultural work. Our results showed that the AWBA-determined risk levels were similar to the subjective risk levels determined by experts. In addition, as the risk level increased, the average risk level increased to a similar extent. Moreover, the differences in risk levels between the AWBA and expert assessments were mostly smaller than the differences in risk levels between other assessment tools and the expert assessments in this study. In conclusion, the AWBA tool developed in this study was demonstrated to be appropriate for use as a tool for assessing various postures commonly assumed in agricultural work. Moreover, we believe that our verification of the assessment tools will contribute to the enhancement of the quality of activities designed to prevent and control work-related musculoskeletal diseases in other industries.

  18. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi

    1994-01-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of 99m Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, γ-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author)

  19. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1994-06-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of [sup 99m]Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, [gamma]-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author).

  20. Whole-body fat oxidation determined by graded exercise and indirect calorimetry: a role for muscle oxidative capacity?

    DEFF Research Database (Denmark)

    Nordby, P; Saltin, B; Helge, J W

    2006-01-01

    During whole-body exercise, peak fat oxidation occurs at a moderate intensity. This study investigated whole-body peak fat oxidation in untrained and trained subjects, and the presence of a relation between skeletal muscle oxidative enzyme activity and whole-body peak fat oxidation. Healthy male...... subjects were recruited and categorized into an untrained (N=8, VO(2max) 3.5+/-0.1 L/min) and a trained (N=8, VO(2max) 4.6+/-0.2 L/min) group. Subjects performed a graded exercise test commencing at 60 W for 8 min followed by 35 W increments every 3 min. On a separate day, muscle biopsies were obtained...... oxidation was determined. The body composition was determined by DEXA. Whole-body peak fat oxidation (250+/-25 and 462+/-33 mg/min) was higher (Ptrained compared with untrained subjects, respectively. Muscle...

  1. Development of personnel dose control system and whole body counter system

    International Nuclear Information System (INIS)

    Ooki, Yasushi; Harato, Kenji

    2005-01-01

    We delivered Personnel Dose Control System to Higashidohri nuclear plant of Tohoku Electric Power Company, in November 2004. In this system development, we automated the registration of radiation worker with close link between this system and Whole Body Counter System. In addition, this system enables the user to reduce workload for accumulation and notification of personal exposure data, because we adopted the system to extract the data effectively operating the terminal PC which the associate company gets ready in their office. We also delivered Whole body Counter System in December 2004, which was developed to measure internal exposure without feeling of oppression in chair-style device for the first time in Japan. This system enables non-operator system for measurement allowing workers to operate by themselves. (author)

  2. Cutaneous noradrenaline measured by microdialysis in complex regional pain syndrome during whole-body cooling and heating

    DEFF Research Database (Denmark)

    Terkelsen, Astrid Juhl; Gierthmühlen, Janne; Petersen, Lars J.

    2013-01-01

    and in healthy volunteers. Seven patients and nine controls completed whole-body cooling (sympathetic activation) and heating (sympathetic inhibition) induced by a whole-body thermal suit with simultaneous measurement of the skin temperature, skin blood flow, and release of dermal noradrenaline. CRPS pain...

  3. Whole-body and multispectral photoacoustic imaging of adult zebrafish

    Science.gov (United States)

    Huang, Na; Xi, Lei

    2016-10-01

    Zebrafish is a top vertebrate model to study developmental biology and genetics, and it is becoming increasingly popular for studying human diseases due to its high genome similarity to that of humans and the optical transparency in embryonic stages. However, it becomes difficult for pure optical imaging techniques to volumetric visualize the internal organs and structures of wild-type zebrafish in juvenile and adult stages with excellent resolution and penetration depth. Even with the establishment of mutant lines which remain transparent over the life cycle, it is still a challenge for pure optical imaging modalities to image the whole body of adult zebrafish with micro-scale resolution. However, the method called photoacoustic imaging that combines all the advantages of the optical imaging and ultrasonic imaging provides a new way to image the whole body of the zebrafish. In this work, we developed a non-invasive photoacoustic imaging system with optimized near-infrared illumination and cylindrical scanning to image the zebrafish. The lateral and axial resolution yield to 80 μm and 600 μm, respectively. Multispectral strategy with wavelengths from 690 nm to 930 nm was employed to image various organs inside the zebrafish. From the reconstructed images, most major organs and structures inside the body can be precisely imaged. Quantitative and statistical analysis of absorption for organs under illumination with different wavelengths were carried out.

  4. Disseminated cysticercosis in a child: whole-body MR diagnosis with the use of parallel imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Atin; Goenka, Ajit Harishkumar [All India Institute of Medical Sciences, Department of Radiology, New Delhi, Delhi (India); Choudhary, Anita; Sahu, Jitendra Kumar; Gulati, Sheffali [All India Institute of Medical Sciences, Department of Paediatrics, New Delhi, Delhi (India)

    2010-02-15

    Cysticercosis is a parasitic disease caused by infestation with the encysted larval stage of the pork tapeworm, Taenia solium. Disseminated cysticercosis is an exceptional expression of this disease characterized by high morbidity due to massive symptomatic parasite burden in the central nervous system, striated muscles, subcutaneous tissues and other organs. Less than 50 such cases have been reported worldwide, and fewer than 10 children. We report on the whole-body MR diagnosis of extensively disseminated cysticercosis in a child. The critical role of whole-body MR as a stand-alone modality in the diagnosis and management of this pleomorphic disease is highlighted. Whole-body MR diagnosis of an infectious disease is unique. (orig.)

  5. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    Energy Technology Data Exchange (ETDEWEB)

    Risco Norrlid, L. del (Swedish Radiation Safety Authority (Sweden)); Halldorsson, O. (Icelandic Radiation Safety Authority (Iceland)); Holm, S. (NM and PET at Copenhagen' s Univ. Hospital (Denmark)); Huikari, J. (Radiation and Nuclear Safety Authority (Finland)); Isaksson, M. (Goeteborg Univ., Dept. Radiation Physics Sahlgren Academy (Sweden)); Lind, B. (Norwegian Radiation Protection Authority (Norway)); Roed, H. (Danish State Institute for Radiation Protection (Denmark))

    2011-02-15

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  6. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    International Nuclear Information System (INIS)

    Risco Norrlid, L. del; Halldorsson, O.; Holm, S.; Huikari, J.; Isaksson, M.; Lind, B.; Roed, H.

    2011-02-01

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  7. Chemical radioprotection to bone marrow stem cells after whole body gamma irradiation to mice

    Energy Technology Data Exchange (ETDEWEB)

    Dey, J.; Dey, T.B.; Ganguly, S.K.; Nagpal, K.K.; Ghose, A.

    1988-11-01

    Protection to mice bone marrow stem cells has been noted as early as two days after whole body gamma ray exposure by prior treatment with combination of hydroxytryptophan (HT) and one of the two thiol drugs viz., aminoethylisothiuronium bromide hydrobromide (AET) (20 mg/kg body weight) and B-mercaptopropionylglicine (MPG). The levels of protection to bone marrow stem cells thus obtained have been compared to that obtained by treating with the optimum radioprotecting dose of AET (200 mg/kg body weight). The study reports the bone marrow stem cells status after two days of 3 Gy, 5 Gy and 10 Gy whole body gamma irradiation in relation to the mentioned radioprotecting treatments as studied by spleen colony forming method.

  8. Whole body effective dose measurements in a fan beam bone mineral densitometer, Lunar expert

    Energy Technology Data Exchange (ETDEWEB)

    Sathiakumar, C.; Griffiths, M.; Cross, P.; Pocock, N.; Freund, J. [St Vincents Hospital, Sydney, NSW (Australia) Department of Nuclear Medicine; Kron, T.; Duggan, L. [Newcastle Mater Misericordiae Hospital, Newcastle, NSW (Australia). Department of Radiation Oncology; Holley, L. [University of Technology, Sydney, NSW (Australia). Department of Health Services

    1998-06-01

    Full text: The most recent generation of DXA machines employ a fan beam geometry and high resolution imaging detector, resulting in decreased scanning time and increased image resolution compared to previous rectilinear scanners, but with higher radiation burden to the patient because of an increasing number of bone mineral density scans, it was felt that independent evaluation of the radiation dose was necessary. The whole body effective dose for an AP lumbar spine scan and femur scan using the EXPERT bone densitometer was calculated for the fast and turbo scanning modes, using thermoluminescence dosimetry (TLD). A method was developed to determine the absorbed dose of the irradiated volume of an organ by summing the dose for each of the coronal areas, which results in a volume dose. The Whole Body Effective dose for AP lumbar spine fast scanning mode is 84.1 {mu}Sv and turbo scanning mode is 56.4 {mu}Sv. The Whole Body Effective dose for femur fast scanning mode is 6.6 {mu}Sv and turbo scanning mode is 4.2 {mu}Sv, with no ovary exposure. A theoretical method has been developed to calculate the organ dose from which whole body effective dose was calculated

  9. Whole-Body versus Local DXA-Scan for the Diagnosis of Osteoporosis in COPD Patients

    Directory of Open Access Journals (Sweden)

    Lidwien Graat-Verboom

    2010-01-01

    Full Text Available Background. Osteoporosis is an extrapulmonary effect of chronic obstructive pulmonary disease (COPD. Diagnosis of osteoporosis is based on BMD measured by DXA-scan. The best location for BMD measurement in COPD has not been determined. Aim of this study was to assess whole-body BMD and BMD of the hip and lumbar spine (local DXA in COPD patients and compare the prevalence of osteoporosis at these locations. Methods. Whole body as well as local DXA-scan were made in 168 COPD patients entering pulmonary rehabilitation. Patient-relevant characteristics were assessed. Prevalence of osteoporosis was determined. Characteristics of patients without osteoporosis were compared to patients with osteoporosis on local DXA. Results. A higher prevalence of osteoporosis was found using local DXA compared to whole-body DXA (39% versus 21%. One quarter of patients without osteoporosis on whole body-DXA did have osteoporosis on local DXA. Significant differences in patient characteristics between patients without osteoporosis based on both DXA measurements and patients with osteoporosis based on local DXA only were found. Conclusions. DXA of the hip and lumbar spine should be made to assess bone mineral density in COPD patients. The lowest T-score of these locations should be used to diagnose osteoporosis.

  10. The effect of whole body vibration exercise on muscle activation ...

    African Journals Online (AJOL)

    African Journal for Physical Activity and Health Sciences ... The effect of whole body vibration exercise (WBV) on muscle activation has recently been a topic for discussion amongst some researchers. ... Participants then performed two different exercises: standing calf raises and prone bridging, without and with WBV.

  11. Corrections of the whole body counting for various measurement geometries

    International Nuclear Information System (INIS)

    Fueloep, M.; Ragan, P.; Lahham, A.

    1996-01-01

    A simple method was suggested for making corrections during the calibration of HPGe detectors employed for the whole-body counting of humans ranging from infants to adults. The results obtained by calculations were verified by using phantoms. (P.A.). 1 tab., 5 figs., 3 refs

  12. Evaluation of whole-body MR to CT deformable image registration

    NARCIS (Netherlands)

    Akbarzadeh, A.; Gutierrez, D.; Baskin, A.; Ay, M. R.; Ahmadian, A.; Alam, N. Riahi; Loevblad, K. O.; Zaidi, H.

    2013-01-01

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based

  13. Linear Representation of Emotions in Whole Persons by Combining Facial and Bodily Expressions in the Extrastriate Body Area

    Science.gov (United States)

    Yang, Xiaoli; Xu, Junhai; Cao, Linjing; Li, Xianglin; Wang, Peiyuan; Wang, Bin; Liu, Baolin

    2018-01-01

    Our human brain can rapidly and effortlessly perceive a person’s emotional state by integrating the isolated emotional faces and bodies into a whole. Behavioral studies have suggested that the human brain encodes whole persons in a holistic rather than part-based manner. Neuroimaging studies have also shown that body-selective areas prefer whole persons to the sum of their parts. The body-selective areas played a crucial role in representing the relationships between emotions expressed by different parts. However, it remains unclear in which regions the perception of whole persons is represented by a combination of faces and bodies, and to what extent the combination can be influenced by the whole person’s emotions. In the present study, functional magnetic resonance imaging data were collected when participants performed an emotion distinction task. Multi-voxel pattern analysis was conducted to examine how the whole person-evoked responses were associated with the face- and body-evoked responses in several specific brain areas. We found that in the extrastriate body area (EBA), the whole person patterns were most closely correlated with weighted sums of face and body patterns, using different weights for happy expressions but equal weights for angry and fearful ones. These results were unique for the EBA. Our findings tentatively support the idea that the whole person patterns are represented in a part-based manner in the EBA, and modulated by emotions. These data will further our understanding of the neural mechanism underlying perceiving emotional persons. PMID:29375348

  14. Improved rectilinear scanning device for the whole body

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    A rectilinear scanning device for whole-body counting is described in which the spacial resolution is considerably improved upon by using photomultipliers with spherically curved photocathodes. By this measure, the distinct non-linearity between the output signals of the phototubes and the actual position of the scintillation in the scintillation crystal, as observed in plane photocathodes, is removed. The distances between the photomultipliers and the scintillation crystal can thus be kept very small whereby an improved statistic and lower noise can be obtained. Furthermore, thicker crystals can be used whereby the efficiency in the determination of higher energies is increased. The electronic signal processing to the reproduction of the nuclide distribution in the body is described in detail. (ORU/LH) [de

  15. Whole body measurements of sodium turnover in offspring of patients with sustained essential hypertension

    International Nuclear Information System (INIS)

    Henningsen, N.C.; Ohlsson, O.; Mattson, S.; Nosslin, B.; Lund Univ.; Lund Univ.

    1982-01-01

    The elimination rate (percent per day) of injected 22 Na using a whole body measurement technique was significantly lower (26%, 5.8 +- 1.5) in normotensive of borderline hypertensive offspring of essential hypertensive patients than in 15 age- and sex-matched, normotensive controls (7.3 +- 1.0). There were no significant differences in exchangeable sodium, whole body potassium or in the urinary exeretion of sodium, potassium and creatinine. The basis for the difference in turnover rate during weck 1 is probably an alteration in the cellular handling of sodium (i.e. increased intracellular sodium) in the still normotensive offspring of patients with essential hypertension. The long-term (more than 100 days) whole body retention of 22 Na was found to be only 0.1% of that injected, which justifies the use of the method on larger population groups. (orig.)

  16. Effect of whole-body cryotherapy on the rheological parameters of blood in older women with spondyloarthrosis.

    Science.gov (United States)

    Kulis, Aleksandra; Misiorek, Anna; Marchewka, Jakub; Głodzik, Jacek; Teległów, Aneta; Dąbrowski, Zbigniew; Marchewka, Anna

    2017-01-01

    Cryotherapy is a physiotherapy method used to treat back pain in older persons. This study aims to evaluate the changes in the rheological parameters of blood in older women with spondyloarthrosis, who underwent whole-body cryotherapy. The experimental group comprised 69 older women with lumbar spondyloarthrosis, aged between 65 and 70 years. Due to the methodology of the procedure, the experimental group was randomly divided into three groups. Each group underwent two weeks of different types of physiotherapy: only whole-body cryotherapy (22 women); only kinesitherapy (23 women); and both cryotherapy and kinesitherapy (24 women). The control group comprised 25 women who did not undergo any form of therapy. The evaluation of the rheological properties of the blood encompassed measurements of the plasma viscosity, the erythrocyte elongation and aggregation indices, and the level of fibrinogen. The conducted rheological tests revealed a significant decrease in the erythrocyte elasticity and aggregation indices only in the group of women who had undergone both whole-body cryotherapy and kinesitherapy. Applying whole-body cryotherapy to older women with spondyloarthrosis decreases the elasticity of erythrocytes and, despite favourable changes in the aggregation parameters, problems with perfusion may still appear. For this reason, the benefit of using whole-body cryotherapy in these persons is debatable.

  17. Evaluation of 111In leukocyte whole body scanning

    International Nuclear Information System (INIS)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-01-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with 111 In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes

  18. Validation of Experimental whole-body SAR Assessment Method in a Complex Indoor Environment

    DEFF Research Database (Denmark)

    Bamba, Aliou; Joseph, Wout; Vermeeren, Gunter

    2012-01-01

    Assessing experimentally the whole-body specific absorption rate (SARwb) in a complex indoor environment is very challenging. An experimental method based on room electromagnetics theory (accounting only the Line-Of-Sight as specular path) to assess the whole-body SAR is validated by numerical...... of the proposed method is that it allows discarding the computation burden because it does not use any discretizations. Results show good agreement between measurement and computation at 2.8 GHz, as long as the plane wave assumption is valid, i.e., for high distances from the transmitter. Relative deviations 0...

  19. Preleukemic change in the bone marrow of whole-body irradiated RFM/Up mice

    International Nuclear Information System (INIS)

    Ludwig, F.C.; Schug, W.G.; Bostick, W.L.; Smoke, M.E.

    1977-01-01

    In the whole-body irradiated mouse, various late effects of radiation are observed after the recovery from acute radiation injury. Some of these account for the familiar proneness of certain mouse strains to develop leukemias. The two experiments described below were designed to identify such preleukemic changes in blood-forming tissues and to find ways to manipulate them experimentally with the purpose of preventing leukemia. Preleukemic change of the bone marrow appears to be a mere quantitative departure from normal in a qualitatively non-malignant tissue. It entails increased proneness of immature cells to react with latent virus. The data, received are consistent with the assumption that this prononess is enhanced (or brought about) by removal of a controlling influence exerted by the mature cells over their precursors. Re-irradiation combined with intravenous bone marrow substitution offsets the leukemogenic influence of an earlier radiation exposure. The effect of re-irradiation on bone marrow displaying preleukemic lesions corroborates conclusions from earlier experiments on the nature of these lesions. (orig./MG) [de

  20. The clinical value of "9"9Tc"m-MDP whole body bone imaging in diagnosing bone metastasis of lung cancer

    International Nuclear Information System (INIS)

    Zhao Yigang; Gou Zhengxing

    2016-01-01

    Objective: To discuss the clinical value of whole body bone imaging on lung cancer bone metastases diagnosis, so as to evaluate the staging of lung cancer patients. Methods: A total of 113 cases of patients diagnosed with lung cancer received whole body imaging, alkaline phosphatase and blood calcium examination. Bone metastasis probability of lung cancer was assessed based on different pathological types. Accuracy rates of bone metastases was compared by whole body bone imaging and suspicious bone metastasis factors (Including one or several items in ostalgia, alkaline phosphatase rising and hypercalcemia). Results The occurrence rate of lung cancer bone metastasis is 36.7%, and the bone metastasis occurrence rate of adenocarcinoma of lung is higher than that of squamous cell lung carcinoma (P < 0.01). Whole body Imaging diagnose of lung cancer bone metastases had sensitivity (92.7%), specificity (83.2%) and accuracy (85.7%). Conclusion: "9"9Tc"m-MDP whole body imaging is a highly sensitive tool to review whole body bone. Lung cancer patients are recommended to receive routine whole body bone imaging. (authors)

  1. Whole brain CT perfusion in acute anterior circulation ischemia: coverage size matters

    International Nuclear Information System (INIS)

    Emmer, B.J.; Rijkee, M.; Walderveen, M.A.A. van; Niesten, J.M.; Velthuis, B.K.; Wermer, M.J.H.

    2014-01-01

    Our aim was to compare infarct core volume on whole brain CT perfusion (CTP) with several limited coverage sizes (i.e., 3, 4, 6, and 8 cm), as currently used in routine clinical practice. In total, 40 acute ischemic stroke patients with non-contrast CT (NCCT) and CTP imaging of anterior circulation ischemia were included. Imaging was performed using a 320-multislice CT. Average volumes of infarct core of all simulated partial coverage sizes were calculated. Infarct core volume of each partial brain coverage was compared with infarct core volume of whole brain coverage and expressed using a percentage. To determine the optimal starting position for each simulated CTP coverage, the percentage of infarct coverage was calculated for every possible starting position of the simulated partial coverage in relation to Alberta Stroke Program Early CT Score in Acute Stroke Triage (ASPECTS 1) level. Whole brain CTP coverage further increased the percentage of infarct core volume depicted by 10 % as compared to the 8-cm coverage when the bottom slice was positioned at the ASPECTS 1 level. Optimization of the position of the region of interest (ROI) in 3 cm, 4 cm, and 8 cm improved the percentage of infarct depicted by 4 % for the 8-cm, 7 % for the 4-cm, and 13 % for the 3-cm coverage size. This study shows that whole brain CTP is the optimal coverage for CTP with a substantial improvement in accuracy in quantifying infarct core size. In addition, our results suggest that the optimal position of the ROI in limited coverage depends on the size of the coverage. (orig.)

  2. Whole brain CT perfusion in acute anterior circulation ischemia: coverage size matters

    Energy Technology Data Exchange (ETDEWEB)

    Emmer, B.J. [Erasmus Medical Centre, Department of Radiology, Postbus 2040, Rotterdam (Netherlands); Rijkee, M.; Walderveen, M.A.A. van [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands); Niesten, J.M.; Velthuis, B.K. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands); Wermer, M.J.H. [Leiden University Medical Centre, Department of Neurology, Leiden (Netherlands)

    2014-12-15

    Our aim was to compare infarct core volume on whole brain CT perfusion (CTP) with several limited coverage sizes (i.e., 3, 4, 6, and 8 cm), as currently used in routine clinical practice. In total, 40 acute ischemic stroke patients with non-contrast CT (NCCT) and CTP imaging of anterior circulation ischemia were included. Imaging was performed using a 320-multislice CT. Average volumes of infarct core of all simulated partial coverage sizes were calculated. Infarct core volume of each partial brain coverage was compared with infarct core volume of whole brain coverage and expressed using a percentage. To determine the optimal starting position for each simulated CTP coverage, the percentage of infarct coverage was calculated for every possible starting position of the simulated partial coverage in relation to Alberta Stroke Program Early CT Score in Acute Stroke Triage (ASPECTS 1) level. Whole brain CTP coverage further increased the percentage of infarct core volume depicted by 10 % as compared to the 8-cm coverage when the bottom slice was positioned at the ASPECTS 1 level. Optimization of the position of the region of interest (ROI) in 3 cm, 4 cm, and 8 cm improved the percentage of infarct depicted by 4 % for the 8-cm, 7 % for the 4-cm, and 13 % for the 3-cm coverage size. This study shows that whole brain CTP is the optimal coverage for CTP with a substantial improvement in accuracy in quantifying infarct core size. In addition, our results suggest that the optimal position of the ROI in limited coverage depends on the size of the coverage. (orig.)

  3. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation.

    Science.gov (United States)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (~15-20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate Ki and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final Ki parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion study

  4. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation

    International Nuclear Information System (INIS)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-01-01

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (∼15–20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate K i and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final K i parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion

  5. Interventions for chronic low back pain: whole body vibration and ...

    African Journals Online (AJOL)

    Objectives. This study explored, described and compared the effects of whole body vibration (WBV) therapy and conventional spinal stabilisation exercises in persons with chronic low back pain (CLBP). Design. A non-randomised sampling technique was used to delineate the base of volunteers gathered by a combination ...

  6. RENAL SAFETY OF PROTON PUMP INHIBITORS

    Directory of Open Access Journals (Sweden)

    A. I. Dyadyk

    2017-01-01

    Full Text Available Proton pump inhibitors are a widely used in clinical practice, and are taken by millions of patients around the world for a long time. While proton pump inhibitors are well-tolerated class of drugs, the number of publications has been raised about adverse renal effects, specially their association with acute tubulointerstitial nephritis. It is one of the leading causes of acute renal injury and have catastrophic long-term consequences called chronic kidney disease. In this review, we consider epidemiology, pathogenesis, diagnostic criteria (including biopsy and morphological pattern, clinical manifestations and treatment of proton pump inhibitors-induced acute tubulointerstitial nephritis. A subclinical course without classical manifestations of a cell-mediated hypersensitivity reaction (fever, skin rash, eosinophilia, arthralgia is characteristic of acute tubulointerstitial nephritis. Increased serum creatinine, decreased glomerular filtration rate, electrolyte disorders, pathological changes in urine tests are not highly specific indicators, but allow to suspect the development of acute tubulointerstitial nephritis. The “gold” standard of diagnosis is the intravital morphological examination of the kidney tissue. Timely diagnosis and immediate discontinuation of the potentially causative drug is the mainstay of therapy and the first necessary step in the early management of suspected or biopsy-proven drug-induced acute tubulointerstitial nephritis. The usage of proton pump inhibitors should be performed only on strict indications with optimal duration of treatment and careful monitoring of kidney function. Multiple comorbidities (older age, heart failure, diabetes, cirrhosis, chronic kidney disease, hypovolemia increase potential nephrotoxicity. Awareness of this iatrogenic complication will improve diagnosis of proton pump inhibitors-induced acute tubulointerstitial nephritis by multidisciplinary specialists and increase the possibility

  7. Determination of iron absorption and excretion by whole-body counting

    International Nuclear Information System (INIS)

    Hollard, D.; Benabid, Y.; Berard, M.; Bonnin, J.; Darnault, J.; Millet, M.

    1969-01-01

    Using a whole-body counter, the authors have studied 59 Fe absorption and loss in 8 normal subjects and in 30 iron deficient patients. Results showed that whole-body counting provided an excellent and simple method for iron retention measurements, obviating many inaccuracies of previous technic. Normal absorption of radio iron with this procedure has ranged from 9 per cent to 20 per cent of the administered tracer in normal subjects, with a mean of 15 per cent. A significant increase in 59 Fe absorption was noted in 21 iron-deficient patients in whom the retention ranged from 40 to 100 per cent. However, 3 iron-deficient patients were found to have low absorption, and their severe iron deficiency could be correlated with this defect in absorption. This method permits also the determination of the rate of iron excretion during the following months and therefore the study of the mechanism of some pathological loss. (authors) [fr

  8. Effect of paracetamol (acetaminophen) on body temperature in acute stroke: A meta-analysis.

    Science.gov (United States)

    Fang, Junjie; Chen, Chensong; Cheng, Hongsen; Wang, Ren; Ma, Linhao

    2017-10-01

    The objective of this study was to assess the efficacy of paracetamol (acetaminophen) on body temperature in acute stroke. Medline, Cochrane Central Register of Controlled Trials, EMBASE, Chinese BioMedical Literature Database, China National Knowledge Infrastructure, and the World Health Organization (WHO) International Clinical Trials Registry Platform were searched electronically. Relevant journals and references of studies included were hand-searched for randomized controlled trials (RCT) and controlled clinical trials (CCT) regarding the efficacy of paracetamol (acetaminophen) on body temperature in acute stroke. Two reviewers independently performed data extraction and quality assessment. Data were analyzed using RevMan 5.3 software by the Cochrane Collaboration. Five studies were included. To compare the efficacy of paracetamol (acetaminophen) in acute stroke, the pooled RR (Risk Ratio) and its 95% CI of body temperature reduction at 24h from the start of treatment were -0.3 (95% CI: -0.52 to -0.08), with statistical significance (P=0.007). Consistently, the pooled RR (Risk Ratio) and its 95% CI of body temperature at 24h from the start of treatment were -0.22 (-0.29, -0.15), with statistical significance (PParacetamol (acetaminophen) is one of the most commonly used antipyretic drugs and has some capability to reduce body temperature through acting on central nervous system. Acetaminophen showed some capability to decrease body temperature for acute stroke. Acetaminophen could not improve functional outcome and reduce adverse events of patients with acute stroke. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Dependence of a whole body counting efficiency on body size and composition

    International Nuclear Information System (INIS)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R.

    2001-01-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  10. Dependence of a whole body counting efficiency on body size and composition

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2001-07-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  11. Response of irradiated diet fed rats to whole body X irradiation

    International Nuclear Information System (INIS)

    Hasan, S.S.; Kushwaha, A.K.S.

    1985-01-01

    The response to whole body X irradiation has been studied in the brain of rats fed both on a normal diet (consisting of equal parts of wheat and gram flour) and on a low protein irradiated diet (consisting of a part of normal diet and three parts of wheat). The activity of enzymes related to the glucose metabolism (glucose 6-phosphate dehydrogenase and fructose diphosphate aldolase) is reduced, while that of peroxidant enzymes (catalase and lipid peroxidase) increased in the brain of rats that received a diet poor in proteins and irradiated diets (normal or hypoproteic). DNA and RNA levels and protein content show a significant reduction in the brain of rats with hypoproteic and irradiated diets. The total body irradiation causes serious alterations in the brain in animals with a hypoproteic malnutritions due both to a low protein and an irradiated diet. The brain of rats fed on a low protein and irradiated diet exhibits after whole body irradiation damages more severe than those in rats fed on a normal irradiated diet

  12. Estimation of throium deposited in thorotrast patients by whole body counter

    International Nuclear Information System (INIS)

    Tatsumi-Miyajima, Junko; Okajima, Shunzo; Takao, Hideaki; Norimura, Toshiyuki.

    1986-01-01

    Thorotrast, a colloidal solution of thorium dioxide was injected to wounded soldiers, for angiography from 1930 to 1945. The patients who received Thorotrast are interesting objects for finding a biological effect due to the internal irradiation by 232 Th. To determine a distribution and body burden of 232 Th, forty-one Thorotrast patients were measured their gamma-rays with a pair of NaI(T1) scintillation detectors coaxially positioned above and below the coach in the whole body counter of Nagasaki University. The comparison between the usual method using constant values and the method using individual values depend on the organ positions determined with CT (Computed Tomography) scanner for patients was performed to estimate the errors due to the individual differences in the detection efficiency of 232 Th. From the results, the estimates by the whole body counter of the amounts of 232 Th deposits in abdominal region were obtained within the uncertainties of 16 %. And the absorbed dose in the liver and the spleen was also estimated from the amounts of 232 Th. (author)

  13. Trial making of a positive drawing phantom and its application to whole-body imaging devices

    International Nuclear Information System (INIS)

    Saegusa, Kenji; Arimizu, Noboru; Nakata, Tsuneo; Toyama, Haruo; Shiina, Isamu.

    1980-01-01

    In whole-body RI imaging, there are more instances of the positive pictures detecting the radioisotopes accumulating in morbid positions, such as Tc-99m bone scanning. The phantoms used to mutually compare RI imaging devices and to test their performance employ negative drawing targets embedded rather than positive ones. A simple positive drawing phantom has been made for trial, and applying this to whole-body scanning devices, the performance and the target drawing ability under different scanning conditions were comparatively examined. Though similar to Rollo's phantom, the phantom made for positive drawing uses acryl plate for its outer structure and target portions. The positive targets are cylindrical, and the diameters are 2, 4, 6, 8, 10, and 20 mm, and the subject contrasts are 5, 2, 1, 0.5 and 0.2. The aqueous solution of Tc-99m of about 2 mCi was injected into the phantom, and this was scanned with a whole-body camera and a multi-detector type whole-body scanner. With the phantom pictures close to actual clinical condition, the positive drawing phantom is conveniently capable of comparing the respective imaging devices for intended purposes. (J.P.N.)

  14. Measurement of whole-body human centers of gravity and moments of inertia.

    Science.gov (United States)

    Albery, C B; Schultz, R B; Bjorn, V S

    1998-06-01

    With the inclusion of women in combat aircraft, the question of safe ejection seat operation has been raised. The potential expanded population of combat pilots would include both smaller and larger ejection seat occupants, which could significantly affect seat performance. The method developed to measure human whole-body CG and MOI used a scale, a knife edge balance, and an inverted torsional pendulum. Subjects' moments of inertia were measured along six different axes. The inertia tensor was calculated from these values, and principal moments of inertia were then derived. Thirty-eight antropometric measurements were also taken for each subject to provide a means for direct correlation of inertial properties to body dimensions and for modeling purposes. Data collected in this study has been used to validate whole-body mass properties predictions. In addition, data will be used to improve Air Force and Navy ejection seat trajectory models for the expanded population.

  15. A critical evalution of 24 hours whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Bessent, R.G.; Scullion, J.E.; Cuthbert, G.F.

    1982-01-01

    In previous studies we have found that 24 hour whole-body retention (WBR) of diphosphonate is a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r = 0.998, p < 0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. The net whole-body count of a phantom representing the 24 hour whole-body distribution of tracer was 98% of that of a uniform phantom. Ten subjects, counted twice within a few minutes to study the effect of repositioning showed a mean difference between counts of only 0.8%. For eleven subjects with traumatic fractures it was found that 9 had normal values for WBR, while 2 had minimally elevated results. For twenty patients with renal disease but no apparent skeletal disease a significant correlation between serum creatinine and WBR was found (r = 0.72, p<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/l. It is suggested that WBR measurement is accurate and the technique is highly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is in the normal range then an elevated WBR result can be assumed to reflect increased skeletal metabolism without further concern as to renal function. (Author)

  16. Whole-body voxel phantoms of paediatric patients—UF Series B

    Science.gov (United States)

    Lee, Choonik; Lee, Choonsik; Williams, Jonathan L.; Bolch, Wesley E.

    2006-09-01

    Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm × 0.86 mm × 3.0 mm, 0.90 mm × 0.90 mm × 5.0 mm, 1.16 mm × 1.16 mm × 6.0 mm, 0.94 mm × 0.94 mm × 6.00 mm and 1.18 mm × 1.18 mm × 6.72 mm, respectively.

  17. Effect of whole body cryotherapy interventions on health-related quality of life in fibromyalgia patients: A randomized controlled trial.

    Science.gov (United States)

    Vitenet, M; Tubez, F; Marreiro, A; Polidori, G; Taiar, R; Legrand, F; Boyer, F C

    2018-02-01

    Although fibromyalgia syndrome (SFM) affects 2-4 percent of adults, research has not identified a preferred therapeutic option for patients worldwide yet. Based on recent findings, it can be expected that whole body cryotherapy can improve health-reported quality of life by alleviating the symptoms of musculoskeletal pain and fatigue. Our aim was to determine whether whole body cryotherapy only can result in improved perceived health and quality of life in fibromyalgia patients. 24 patients with fibromyalgia diagnosis were randomized into 2 groups (n=11 in the whole body cryotherapy group, n=13 in the control group). In the whole body cryotherapy group, 10 sessions of whole body cryotherapy were performed (in addition to usual care) in a standard cryotherapy room over a duration of 8days. Subjects in the control group did not change anything in their everyday activities. Quality of life was assessed just before and one month after treatment. Compared with the control group, patients in the whole body cryotherapy group reported significantly improved for health-reported quality of life. These effects lasted for at least one month following intervention. Based on these findings, whole body cryotherapy can be recommended as an effective clinically adjuvant approach in the improvement of health-related quality of life in fibromyalgia patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Effect of whole body irradiation on different tissues

    International Nuclear Information System (INIS)

    Casati, V.; Nardino, A.; Tomassi, I.; Becciolini, A.; Rizzi, M.; Martelli, T.

    1979-01-01

    The uptake and elimination of 14 C leucine were analysed in controls and in rats irradiated 2 h before injection with 8 Gy whole-body irradiation. Plasma, small intestine, kidney and skin were assayed after homogenization for TCA soluble and insoluble activity curves. In highly differentiated tissues with poor proliferative activity and low protein turnover, the uptake and elimination of the tracer did not appear to be affected by irradiation. In the small intestine differences between control and irradiated animals seemed significant. (Auth.)

  19. Effective dose estimation in whole-body multislice CT in paediatric trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Robin D.; Saueressig, Ulrich; Kotter, Elmar; Langer, Mathias; Bley, Thorsten A. [University Hospital, Department of Radiology, Freiburg im Breisgau (Germany); Strohm, Peter C.; Zwingmann, Joern; Suedkamp, Norbert P. [University Hospital, Department of Orthopaedic and Trauma Surgery, Freiburg im Breisgau (Germany); Uhl, Markus [University Hospital, Department of Radiology, Section of Paediatric Radiology, Freiburg im Breisgau (Germany)

    2009-03-15

    The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the clinicians with relevant information to initiate life-saving therapy. Radiologists should use special paediatric protocols that include dose-saving mechanisms to keep the effective dose as low as possible. Further studies are needed to examine and advance dose-saving strategies in MSCT, especially in children. (orig.)

  20. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L. [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Bamberg, Fabian [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); University Hospital Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lochner, Elena [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); Findeisen, Hannes M. [University Hospital Muenster, Department of Cardiology and Angiology, Muenster (Germany); Parhofer, Klaus G. [Ludwig Maximilians University, Klinikum Grosshadern, Department of Internal Medicine II, Munich (Germany); Schoenberg, Stefan O. [University Medical Center Mannheim, Department of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2016-05-15

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  1. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    International Nuclear Information System (INIS)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L.; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M.; Parhofer, Klaus G.; Schoenberg, Stefan O.

    2016-01-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  2. Back disorders in crane operators exposed to whole-body vibration

    NARCIS (Netherlands)

    Bongers, P. M.; Boshuizen, H. C.; Hulshof, C. T.; KOEMEESTER, A. P.

    1988-01-01

    In The Netherlands so far little research has been carried out to investigate the health effects of exposure to whole-body vibration at work. In a retrospective (10-year) follow-up study, the incidence of permanent work disabilities in crane operators exposed to vibration was compared to that of a

  3. Can segmental model reductions quantify whole-body balance accurately during dynamic activities?

    Science.gov (United States)

    Jamkrajang, Parunchaya; Robinson, Mark A; Limroongreungrat, Weerawat; Vanrenterghem, Jos

    2017-07-01

    When investigating whole-body balance in dynamic tasks, adequately tracking the whole-body centre of mass (CoM) or derivatives such as the extrapolated centre of mass (XCoM) can be crucial but add considerable measurement efforts. The aim of this study was to investigate whether reduced kinematic models can still provide adequate CoM and XCoM representations during dynamic sporting tasks. Seventeen healthy recreationally active subjects (14 males and 3 females; age, 24.9±3.2years; height, 177.3±6.9cm; body mass 72.6±7.0kg) participated in this study. Participants completed three dynamic movements, jumping, kicking, and overarm throwing. Marker-based kinematic data were collected with 10 optoelectronic cameras at 250Hz (Oqus Qualisys, Gothenburg, Sweden). The differences between (X)CoM from a full-body model (gold standard) and (X)CoM representations based on six selected model reductions were evaluated using a Bland-Altman approach. A threshold difference was set at ±2cm to help the reader interpret which model can still provide an acceptable (X)CoM representation. Antero-posterior and medio-lateral displacement profiles of the CoM representation based on lower limbs, trunk and upper limbs showed strong agreement, slightly reduced for lower limbs and trunk only. Representations based on lower limbs only showed less strong agreement, particularly for XCoM in kicking. Overall, our results provide justification of the use of certain model reductions for specific needs, saving measurement effort whilst limiting the error of tracking (X)CoM trajectories in the context of whole-body balance investigation. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Calibration of whole-body counters for transuranic radionuclides by using total-body donations to the United States Transuranium Registry

    International Nuclear Information System (INIS)

    Palmer, H.E.; Heid, K.R.; Breitenstein, B.D.; Durbin, P.W.; McInroy, J.F.

    1985-01-01

    One of the many benefits of the whole-body donation programme of the United States Transuranium Registry is the calibration of whole-body counters by measuring a donated body containing radioactivity before radiochemical analysis of the body occurs. These measurements have provided the best existing calibration factors for measuring 241 Am and 239 Pu in the skeleton of living people. In one case where the body contained an easily measurable quantity of 241 Am, the 241 Am content was found to be the same for identical bones on the right and left sides of the body. The bones from the right side of the body and every other vertebrae were radiochemically analysed and the bones from the left side were reserved. These latter have a known quantity of naturally distributed 241 Am based on the analysis of bones from the right side. These reserved bones are being incorporated into tissue equivalent body parts for future calibrations and interlaboratory comparisons. The measurements on the total body and the reserved bones have already been very useful in determining the contribution of skeletal activity to that of lung measurements and determining a calibration factor for measuring 239 Pu deposited in the skeleton. In the future it is planned to periodically make in vivo measurements on those people participating in the total-body donation programme so that calibration factors can be obtained for lung and liver content after subsequent analysis of these tissues. (author)

  5. Impact of whole-body rehabilitation in patients receiving chronic mechanical ventilation.

    Science.gov (United States)

    Martin, Ubaldo J; Hincapie, Luis; Nimchuk, Mark; Gaughan, John; Criner, Gerard J

    2005-10-01

    To evaluate the prevalence and magnitude of weakness in patients receiving chronic mechanical ventilation and the impact of providing aggressive whole-body rehabilitation on conventional weaning variables, muscle strength, and overall functional status. Retrospective analysis of 49 consecutive patients. Multidisciplinary ventilatory rehabilitation unit in an academic medical center. Forty-nine consecutive chronic ventilator-dependent patients referred to a tertiary care hospital ventilator rehabilitation unit. None. Patients were 58 +/- 7 yrs old with multiple etiologies for respiratory failure. On admission, all patients were bedridden and had severe weakness of upper and lower extremities measured by a 5-point muscle strength score and a 7-point Functional Independence Measurement. Postrehabilitation, patients had increases in upper and lower extremity strength (p respiratory muscle training with an improvement in strength, weaning outcome, and functional status. Whole-body rehabilitation should be considered a significant component of their therapy.

  6. Importance of Intercomparison Exercises in Assessment of Internal Exposure by Whole-Body Counter

    International Nuclear Information System (INIS)

    Andrasi, A.

    2001-01-01

    Full text: Basic requirement for any kind of measurement is to check and prove the reliability and correctness of the measured results. Quality assurance programmes require several activities among which the participation in intercomparison exercises plays an important role. Since the determination of radioactive materials in the human body by whole-body counting technique implies many sources of uncertainties the reliability of calibration data and consequently the measured results have to be checked by participation in intercomparison quality control programmes. In these programmes mostly different kinds of phantoms simulating the human body are circulated among the participating laboratories, however sometimes contaminated persons are also subjects of intercomparison measurements. There are guidelines in several countries laid down concerning the requirements of whole-body counter measurements where the performance criteria for the relative bias, precision and minimum detectable amounts are formulated. These quantities are mostly the subject of intercomparison programmes. The whole body counter laboratory of the KFKI Atomic Energy Research Institute participated in intercomparison exercises several times in the last few years. The lessons learned during these activities helped in checking the capabilities of applied methods and measuring geometry as well as contributed in improving the accuracy of the measured results. A short overview on the previous international intercomparison exercises their main characteristics the results obtained and conclusions drawn are discussed in the paper with special attention to those in which also our laboratory participated. (author)

  7. Whole-body counting in the Marshall Islands

    International Nuclear Information System (INIS)

    Sun, L.C.; Clinton, J.; Kaplan, E.; Meinhold, C.B.

    1991-01-01

    In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish 137 Cesium body contents among the Enewetak, Rongelap and Utirik populations. 137 Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. 137 Cs body burdens tended to increase with age for both sexes, and were higher in males. The average 137 Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22±4 μSv. For Utirik, the dose was 33± 3 μSv. Since 1985 the Rongelap people have been self-exiled to Mejatto. Biological elimination should have reduced their dose to virtually zero, and the measured dose was 2±2 μSv. If they had remained on Rongelap Island, the calculated dose would have been 99 μSv, which is about one-third of the background dose. 7 refs., 1 tab

  8. Local forearm and whole-body respiratory quotient in humans after an oral glucose load

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Madsen, J

    1993-01-01

    the glucose load and had not returned to baseline level at the end of the experiment. Whole-body respiratory quotient (RQ) was, on average, 0.80 (SD 0.05) in the baseline condition and increased to a maximum of 0.91 (0.03) and then decreased to baseline level at the end of the experiment. The local forearm.......17) to 0.63 (0.17) 30 min after the glucose load (P glucose load RQ increased to a maximum level at 0.95 (0.22) and decreased then gradually to baseline level. The experiments emphasize several methodological problems in the measurement of local forearm RQ. The whole-body RQ......The effects of an oral glucose load of 75 g on the local forearm and whole-body energy thermogenesis were measured in normal subjects during the 4 h after the glucose intake. Simultaneous assessment of substrate metabolism in the forearm was performed. Energy expenditure (EE) increased after...

  9. Whole-body cryotherapy: empirical evidence and theoretical perspectives

    Directory of Open Access Journals (Sweden)

    Bleakley CM

    2014-03-01

    Full Text Available Chris M Bleakley,1 François Bieuzen,2 Gareth W Davison,1 Joseph T Costello3 1Sport and Exercise Science Research Institute, Faculty of Life and Health Sciences, University of Ulster, Newtownabbey, Northern Ireland; 2Research Department, Laboratory of Sport, Expertise and Performance, French National Institute of Sport (INSEP, Paris, France; 3School of Exercise and Nutrition Sciences and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia Abstract: Whole-body cryotherapy (WBC involves short exposures to air temperatures below –100°C. WBC is increasingly accessible to athletes, and is purported to enhance recovery after exercise and facilitate rehabilitation postinjury. Our objective was to review the efficacy and effectiveness of WBC using empirical evidence from controlled trials. We found ten relevant reports; the majority were based on small numbers of active athletes aged less than 35 years. Although WBC produces a large temperature gradient for tissue cooling, the relatively poor thermal conductivity of air prevents significant subcutaneous and core body cooling. There is weak evidence from controlled studies that WBC enhances antioxidant capacity and parasympathetic reactivation, and alters inflammatory pathways relevant to sports recovery. A series of small randomized studies found WBC offers improvements in subjective recovery and muscle soreness following metabolic or mechanical overload, but little benefit towards functional recovery. There is evidence from one study only that WBC may assist rehabilitation for adhesive capsulitis of the shoulder. There were no adverse events associated with WBC; however, studies did not seem to undertake active surveillance of predefined adverse events. Until further research is available, athletes should remain cognizant that less expensive modes of cryotherapy, such as local ice-pack application or cold-water immersion, offer comparable

  10. Amino acid metabolism and whole-body protein turnover in lambs ...

    African Journals Online (AJOL)

    The effect of protein supplementation of a wheat straw diet on the metabolism of lysine, leucine, methionine and urea, and on whole-body protein turnover rate was investigated in lambs. The metabolism of lysine and leucine is reported elsewhere (Cronje et aI., 1992); in this paper methionine metabolism is discussed, and ...

  11. Short-term lower-body plyometric training improves whole body BMC, bone metabolic markers, and physical fitness in early pubertal male basketball players.

    Science.gov (United States)

    Zribi, Anis; Zouch, Mohamed; Chaari, Hamada; Bouajina, Elyes; Ben Nasr, Hela; Zaouali, Monia; Tabka, Zouhair

    2014-02-01

    The effects of a 9-week lower-body plyometric training program on bone mass, bone markers and physical fitness was examined in 51 early pubertal male basketball players divided randomly into a plyometric group (PG: 25 participants) and a control group (CG: 26 participants). Areal bone mineral density (aBMD), bone mineral content (BMC), and bone area (BA) in the whole body, L2-L4 vertebrae, and in total hip, serum levels of osteocalcin (Oc) and C-terminal telopeptide fragment of Type I collagen (CTx), jump, sprint and power abilities were assessed at baseline and 9 weeks. Group comparisons were done by independent student's t-test between means and analyses of (ANOVA) and covariance (ANCOVA), adjusting for baseline values. PG experienced a significant increase in Oc (p BMC and BA in any measured site, except in whole body BMC of the PG. A positive correlation was observed between percentage increase (Δ%) of physical fitness and those of (Oc) for the PG. In summary, biweekly sessions of lower body plyometric training program were successful for improving whole body BMC, bone formation marker (Oc) and physical fitness in early pubertal male basketball players.

  12. Distribution of /sup 63/Ni in mice by means of whole body autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Saito, T [Nihon Univ., Tokyo. School of Dentistry

    1974-11-01

    The uptake of Ni which was known to be contained in the dental alloy to the mammalian tissue was studied. /sup 63/Ni was injected intravenously to mice, and its distribution in their body was observed by counting radioactivity using whole body autoradiography and liquid scintillation counter from 30 minutes after the injection to 3 weeks later. Whole body autography revealed high uptake in the kidney, lung, incisor, intervertebral disc, epidermis cuticle, hair follicle, and liver during 30 minutes later to 8 hours period, and in the lung, renal cortex, central nerve, epidermis cuticle, and hair follicle during 2 days to 3 weeks period. /sup 63/Ni taken up in the tissue or organs rapidly disappeared by 8 hours period, and the rank of high uptake tissues slightly changed during 30 minutes later to 8 hours period. /sup 63/Ni administered in the body was considered to be excreted through the kidney, however, /sup 63/Ni taken up in the central nerve showed remarkably delayed excretion.

  13. Myelopoiesis in whole-body-irradiated beagles

    International Nuclear Information System (INIS)

    Stevenson, A.F.G.

    1985-01-01

    The influence of dose-rate (DR) (either 5.2 or 52 cGy/min.) on the regeneration of bone marrow (BM) myelopoietic progenitor cells was studied in beagles after exposure to whole-body-irradiation (235, 375 and 1500 cGy + autologous BM-transplantation). Myelopoietic progenitor cells were assayed as colony-forming units in agar cultures (GM-CFU), in correlation with the colony-stimulation activity (CSA) in serum. At 235 cGy, the influence of DR on the recovery of GM-CFU was insignificant. However, at 375 cGy, the recovery was critically dependent on the DR. Depletion of GM-CFU numbers elevated CSA levels above pre-irradiation values. The DR determines the regenerative ability when the dose itself is critical to survival of the least number of hematopoietic stem cells (HSC) necessary for restitution. (author)

  14. Adaptive statistical iterative reconstruction technology in the application of PET/CT whole body scans

    International Nuclear Information System (INIS)

    Xin Jun; Zhao Zhoushe; Li Hong; Lu Zhe; Wu Wenkai; Guo Qiyong

    2013-01-01

    Objective: To improve image quality of low dose CT in whole body PET/CT using adaptive statistical iterative reconstruction (ASiR) technology. Methods: Twice CT scans were performed with GE water model,scan parameters were: 120 kV, 120 and 300 mA respectively. In addition, 30 subjects treated with PET/CT were selected randomly, whole body PET/CT were performed after 18 F-FDG injection of 3.70 MBq/kg, Sharp IR+time of flight + VUE Point HD technology were used for 1.5 min/bed in PET; CT of spiral scan was performed under 120 kV using automatic exposure control technology (30-210 mA, noise index 25). Model and patients whole body CT images were reconstructed with conventional and 40% ASiR methods respectively, and the CT attenuation value and noise index were measured. Results: Research of model and clinical showed that standard deviation of ASiR method in model CT was 33.0% lower than the conventional CT reconstruction method (t =27.76, P<0.01), standard deviation of CT in normal tissues (brain, lung, mediastinum, liver and vertebral body) and lesions (brain, lung, mediastinum, liver and vertebral body) reduced by 21.08% (t =23.35, P<0.01) and 24.43% (t =16.15, P<0.01) respectively, especially for normal liver tissue and liver lesions, standard deviations of CT were reduced by 51.33% (t=34.21, P<0.0) and 49.54% (t=15.21, P<0.01) respectively. Conclusion: ASiR reconstruction method was significantly reduced the noise of low dose CT image and improved the quality of CT image in whole body PET/CT, which seems more suitable for quantitative analysis and clinical applications. (authors)

  15. Possibilities of whole-body MRI for investigating musculoskeletal diseases; Moeglichkeiten der Ganzkoerper-MRT zur Diagnostik muskuloskelettaler Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Lenk, S.; Claussen, C.D.; Schlemmer, H.P. [Klinikum der Eberhardt-Karls-Universitaet Tuebingen, Abteilung fuer Diagnostische Radiologie (Germany); Fischer, S. [Universitaetsklinikum Tuebingen, Abteilung fuer Strahlentherapie (Germany); Koetter, I. [Universitaetsklinikum Tuebingen, Abteilung fuer Haematoonkologie (Germany)

    2004-09-01

    This contribution outlines possibilities and limitations of whole-body MRI for investigating musculoskeletal diseases. Benefits and drawbacks of the novel whole-body MRI technology are discussed and a possible whole-body MRI sequence protocol for musculoskeletal examinations is proposed. Muscle, joint and bone diseases are discussed in which the application of whole-body MRI may be of advantage. Particularly, polymyositis, muscledystrophy, rheumatoid arthritis, spondylitis ancylosans, multiple trauma, skeletal metastases, multiple myeloma and malignant lymphoma are mentioned. Whole-body MRI opens new advantages for the examination of multifocal musculoskeletal diseases. The clinical benefit of this method for particular diseases has to be evaluated in further studies, however. (orig.) [German] Dieser Beitrag gibt eine Uebersicht ueber die Moeglichkeiten und Limitationen der Ganzkoerper-MRT fuer die Diagnostik von Erkrankungen des muskuloskelettalen Systems. Es werden die Vor- und Nachteile der Ganzkoerper-MRT eroertert und ein Sequenzprotokoll fuer die muskuloskelettale Diagnostik vorgeschlagen. Auf Muskel-, Gelenk- und Knochenerkrankungen, bei denen der Einsatz der Ganzkoerper-MRT indiziert erscheint, dabei insbesondere Polymyositis, Muskeldystrophie, rheumatoide Arthritis, Spondylitis ankylosans, Polytrauma, Skelettmetastasen, Plasmozytom und das maligne Lymphom wird eingegangen. Die Ganzkoerper-MRT bietet neue Moeglichkeiten, insbesondere zur Ausbreitungsdiagnostik und Verlaufskontrolle multifokaler muskuloskelettaler Erkrankungen. Der klinische Nutzen dieser Methode fuer die einzelnen Erkrankungsentitaeten muss in weiteren Studien evaluiert werden. (orig.)

  16. Diagnostic imaging in polytrauma: comparison of radiation exposure from whole-body MSCT and conventional radiography with organ-specific CT

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Lorenzen, M.; Weber, C.; Adam, G.; Nagel, H.D.

    2004-01-01

    Purpose: To compare the radiation dose of whole-body multislice CT (MSCT) and conventional radiography with organ-specific CT in polytrauma. Materials and Methods: The whole-body MSCT encompassing brain, neck and midface, chest, abdomen and pelvis was performed on a Somatom Volume Zoom (Siemens). Conventional radiography consisted of chest and cervical, thoracic and lumbar spine in two views as well as pelvis. Polymat, Siemens. Three combinations of organ specific CT were chosen: CT examination of (1) head and cervical spine, (2) head, cervical spine and chest, (3) head, cervical spine and abdomen. The effective doses of whole-body MSCT and conventional radiography with organ-specific CT were calculated. Results: Effective doses were 20 mSv for whole-body MSCT, 2 mSv for conventional x-ray, and 5 mSv for combination (1), 8 mSv for combination (2) and (3) 16 mSv for combination (3) of the organ-specific CT. The ratio of radiation dose between whole-body MSCT and radiography was 10: 1. This ratio was reduced to 3: 1, 2: 1 and 1: 1 when a combination of radiography and CT was performed. Conclusions: Whole-body MSCT in polytrauma compared to conventional radiography with organ-specific CT induces a threefold increased dose in unfavorable situations and no increased dose in favorable situations. Nevertheless, routine use of whole-body MSCT should be critically evaluated and should be adapted to the clinical benefit. (orig.) [de

  17. Effect of rat whole-body irradiation on oxidase chain and glucose-6-phosphatase of liver microsome: influence of cysteamine

    International Nuclear Information System (INIS)

    Bernard, Pierre.

    1979-11-01

    Three enzymatic systems of the male rat liver endoplasmic reticulum were studied by biochemical methods. Two means of investigation were used: - whole-body irradiation of the animal, - administration of cysteamine. The results obtained are discussed, in view of the functioning of these enzymatic systems, from two viewpoints: - the study of enzymatic radiolesions in relation to the radiobiological effect on the animal, the organ and the sub-cellular organite, - the study of chemical radioprotection. After a 900 R whole-body gamma irradiation a severe drop was observed in the enzymatic activity of two essential elements of the microsome oxydase chain: NADPH cytochrome P450 reductase and ethylmorphine N-demethylation. Glucose 6 phosphatase is also impaired by irradiation. Here it seems that the microsomal protein fraction could be responsible for the change in the enzyme activity. The irradiation effect is therefore not specific to one enzyme. The changes in these enzymatic activities correspond to the different phases of the acute irradiation syndrome which also affects the weight of the experimental animal and of the organ studied. Cysteamine used under chemical radioprotection conditions was found to be especially useful as a means of investigation complementary to the study of enzymatic radiolesions. From the combined action of irradiation and of the radioprotector it was possible to obtain a partial idea of the mechanisms of these radiolesions [fr

  18. Effects of whole-body vibration on muscle strength and power of elderly: A systematic review

    Directory of Open Access Journals (Sweden)

    Monique Opuszcka Campos

    2014-02-01

    Full Text Available The aim of this systematic review was to summarize available scientific evidence on the utilization of whole body vibration as an alternative method to promote effective modifications on muscle strength and power in the aging population.  Scientific studies were retrieved from the following databases: Medline, Scielo, Lillacs, Cochrane Library, PEDro and Science Citation Index. The PEDro scale was used to assess the quality of the included studies, while content went through a critical analysis. From the 91 studies retrieved, 75 were excluded and 16 attended the selection criteria. From the16, the majority (68.8% presented from moderate to high methodological quality. Whole-body vibration associated to both isometric and dynamic exercises seemed to constitute an alternative for therapeutic intervention to improve muscular strength and power of healthy elderly. However, due to the characteristics of the designs of the studies reviewed and the threats to their internal validity (i.e., the absence of the control condition to the vibratory stimulus it was challenging to establish the additional effects of the whole-body vibration on the target population. Divergent findings were found for the whole-body vibration effect on muscular power. It is still necessary to conduct randomized control trials to establish the real effectiveness of this kind of intervention.

  19. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto

    1997-01-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  20. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1997-10-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  1. Benefits of whole body vibration training in patients hospitalised for COPD exacerbations - a randomized clinical trial.

    Science.gov (United States)

    Greulich, Timm; Nell, Christoph; Koepke, Janine; Fechtel, Juliane; Franke, Maja; Schmeck, Bernd; Haid, Daniel; Apelt, Sandra; Filipovic, Silke; Kenn, Klaus; Janciauskiene, Sabina; Vogelmeier, Claus; Koczulla, Andreas Rembert

    2014-04-11

    Patients with stable COPD show improvements in exercise capacity and muscular function after the application of whole body vibration. We aimed to evaluate whether this modality added to conventional physiotherapy in exacerbated hospitalised COPD patients would be safe and would improve exercise capacity and quality of life. 49 hospitalised exacerbated COPD patients were randomized (1:1) to undergo physiotherapy alone or physiotherapy with the addition of whole body vibration. The primary endpoint was the between-group difference of the 6-minute walking test (day of discharge - day of admission). Secondary assessments included chair rising test, quality of life, and serum marker analysis. Whole body vibration did not cause procedure-related adverse events. Compared to physiotherapy alone, it led to significantly stronger improvements in 6-minute walking test (95.55 ± 76.29 m vs. 6.13 ± 81.65 m; p = 0.007) and St. Georges Respiratory Questionnaire (-6.43 ± 14.25 vs. 5.59 ± 19.15, p = 0.049). Whole body vibration increased the expression of the transcription factor peroxisome proliferator receptor gamma coactivator-1-α and serum levels of irisin, while it decreased serum interleukin-8. Whole body vibration during hospitalised exacerbations did not cause procedure-related adverse events and induced clinically significant benefits regarding exercise capacity and health-related quality of life that were associated with increased serum levels of irisin, a marker of muscle activity. German Clinical Trials Register DRKS00005979. Registered 17 March 2014.

  2. Potential effects of whole-body vibration exercises on blood flow ...

    African Journals Online (AJOL)

    Feasible clinical strategies such as whole-body vibration exercise (WBVE) are being used without a clear understanding of its effects. The aim of the present study is to review the effects of the WBVE on blood flow kinetics and its feasibility in different populations. Material and Methods: The level of evidence (LE) of selected ...

  3. Calibration of the LDI/CDTN Whole Body Counter using three physical phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, F.G.; Fonseca, T.C.F. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dep. de Engenharia Nuclear; Mendes, B.M.; Silva, T.A. da; Lacerda, M.A.S.; Pinto, J.R.; Prates, S.; Filho, N.N.A., E-mail: fgpaiva92@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte/MG (Brazil); Dantas, A.L.A.; Dantas, B.M. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine monitoring of internal contamination of the Individuals Occupationally Exposed (IOEs) at the Unit for Research and Production of Radiopharmaceuticals (UPPR/CDTN), the Research Reactor TRIGA-IPR-R1/CDTN and other workplaces of the institute where there is a risk of accidental intakes. Additionally, LDI supports the Institute of Radiation Protection and Dosimetry (IRD/CNEN) to attend radiological emergencies. The determination of photon emitting radionuclides in the human body requires the use of calibration techniques in different counting geometries for converting the count rates into activity in organs and tissues. This paper presents and discusses the calibration of the LDI/CDTN Whole Body Counter (WBC) using a standard BOMAB phantom (Bottle Mannequin Absorber) compared to a home-made phantom produced with Polyethylene Terephthalate bottles (PET). Initially, the BOMAB was filled with a cocktail containing {sup 60}Co, {sup 137}Cs and {sup 133}Ba. The phantom was counted at the LDI whole body counter and an Efficiency x Energy curve was obtained. Subsequently the PET-BOMAB was filled with the same standard source and a second curve was determined. The efficiency values in each region of interest as well as the shape of both curves were found to be equivalent. The results validate the use of the PET-BOMAB for the calibration of whole body geometry applied to the measurement of high energy photon emitting radionuclides in the energy region evaluated in this work. (author)

  4. Fatal veno-occlusive disease of the liver after chemotherapy, whole-body irradiation and bone marrow transplantation for refractory acute leukaemia

    International Nuclear Information System (INIS)

    Jacobs, P.; Miller, J.L.; Uys, C.J.; Dietrich, B.E.

    1979-01-01

    Rapid onset of liver failure with fatal outcome occured in a young woman after successful bone marrow transplantation undertaken for refractory acute leukaemia. Centrilobular necrosis was demonstrated at autopsy and was attributed to prior cytotoxic chemotherapy, possibly potentiated by the total-body irradiation that was used in preparation for the transplant. This association between liver damage and prolonged drug therapy, coupled with the short median survival currently achieved within these chemotherapy regimens, has initiated an evaluation of bone marrow transplantation in patients with leukaemia during the first complete remission, rather than at a later stage when cumulative drug toxicity to the liver may have taken place

  5. The use of comparative 137Cs body burden estimates from environmental data/models and whole body counting to evaluate diet models for the ingestion pathway

    International Nuclear Information System (INIS)

    Robison, W.L.; Sun, C.

    1997-01-01

    Rongelap and Utirik Atolls were contaminated on 1 March 1954, by a U.S. nuclear test at Bikini Atoll code named BRAVO. The people at both atolls were removed from their atolls in the first few days after the detonation and were returned to their atolls at different times. Detailed studies have been carried out over the years by Lawrence Livermore National Laboratory (LLNL) to determine the radiological conditions at the atolls and estimate the doses to the populations. The contribution of each exposure pathway and radionuclide have been evaluated. All dose assessments show that the major potential contribution to the estimated dose is 137 Cs uptake via the terrestrial food chain. Brookhaven National Laboratory (BNL) has carried out an extensive whole body counting program at both atolls over several years to directly measure the 137 Cs body burden. Here we compare the estimates of the body burdens from the LLNL environmental method with body burdens measured by the BNL whole body counting method. The combination of the results from both methods is used to evaluate proposed diet models to establish more realistic dose assessments. Very good agreement is achieved between the two methods with a diet model that includes both local and imported foods. Other diet models greatly overestimate the body burdens (i.e., dose) observed by whole body counting. The upper 95% confidence limit of interindividual variability around the population mean value based on the environmental method is similar to that calculated from direct measurement by whole body counting. Moreover, the uncertainty in the population mean value based on the environmental method is in very good agreement with the whole body counting data. This provides additional confidence in extrapolating the estimated doses calculated by the environmental method to other islands and atolls. 46 refs., 8 figs., 5 tabs

  6. The bird's-eye views of the whole body bone scans

    Energy Technology Data Exchange (ETDEWEB)

    Machida, K; Akaike, A; Hayashi, S; Watari, T; Yasukochi, H [Tokyo Univ. (Japan). Faculty of Medicine

    1975-07-01

    Using a newly developed whole body gamma scanner (Toshiba-RDA-601), the authors recorded whole body bone scans in 5 patients (two normal, osteomalacia, bone metastases of prostate cancer and bone metastases of breast cancer), and compared the regular scintiscans with those of bird's-eye view images which were made with the data processor of the scanner. The scans were started about 2 hours after intravenous injection of 3 to 8 mCi of sup(99m)Tc-monofluorophosphate stannous fluoride. The recorded bird's-eye view scans displayed the skeletal system vividly as they were, and the distribution of radioactivity semiquantitatively. It was concluded that the bird'eye view scan is superior to the regular scan, in view of the point that it expresses the distribution of radioactivity semiquantitatively and enables one to know the amount of abnormally accumulated radioactivities by measuring the height of the peak of the diseased area, although this is very difficult in the regular scan. More clinical studies are needed in order to determine which is better for detecting abnormal part clinically.

  7. Glucose-induced thermogenesis in patients with small cell lung carcinoma. The effect of acute beta-adrenergic inhibition

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Tuxen, C

    1994-01-01

    Seven patients with histologically verified small cell lung carcinoma were given an oral glucose load of 75 g on two occasions to examine the effect of glucose on whole body and forearm thermogenesis with and without acute beta-adrenergic inhibition with propranolol. Whole body energy expenditure...

  8. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L.

    2009-01-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  9. Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-L-tyrosine.

    Science.gov (United States)

    Pauleit, Dirk; Floeth, Frank; Herzog, Hans; Hamacher, Kurt; Tellmann, Lutz; Müller, Hans-W; Coenen, Heinz H; Langen, Karl-J

    2003-04-01

    The whole-body distribution of O-(2-[(18)F]fluoroethyl)- l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV

  10. Estimation of the protein synthesis rates of the whole body of growing broilers

    International Nuclear Information System (INIS)

    Koehler, R.; Pahle, T.; Gruhn, K.; Zander, R.; Jeroch, H.; Gebhardt, G.

    1988-01-01

    The purpose of the investigations was to prove a method, developed for monogastric mammalians, based on a 3-compartment model and assuming a proportional growth of the pools of total N, whether it is applicable to growing poultry. The tracer, 15 N-L-lysine, was given quasi-continuously for four days. In this time and in the following period of five days without tracer intake, the 15 N excretion in the urine was measured. The average of the live weight of the broiler cockerels was 1724 g. The animals were colostomized for sampling the urine separately. Using the fluxes of lysine, the calculation of the whole-body protein synthesis rate was 64.1 g/d. The protein degradation rate was 54.4 g/d. The adequate values of the fractional rates of protein synthesis and degradation for the whole body (without feathers) were 23.3% and 19.8%, resp. Thus it is clearly shown, that the method applied gives real data of the parameters of the N metabolism for growing broilers, being in the range of values for muscle proteins and proteins of the whole body of growing poultry, published by other authors. (author)

  11. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: cmo@cdtn.br

    2009-07-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  12. Estimating the whole-body exposure annual dose of radiation workers of petroleum nuclear well logging

    International Nuclear Information System (INIS)

    Tian Yizong; Gao Jianzheng; Liu Wenhong

    2006-01-01

    Objective: By imitating experiment of radioactive sources being installed, to estimate the annual whole-body exposure dose of radiation workers of petroleum nuclear determining wells; Methods: To compre the values of the theory, imitating experiment and γ individual dose monitor calculations. Results: The three values measured above tally with one anather. Conclusion: The annual whole-body exposure doses of radiation workers of petroleum nuclear determining wells are no more than 5 mSv. (authors)

  13. Sensorimotor Reorganizations of Arm Kinematics and Postural Strategy for Functional Whole-Body Reaching Movements in Microgravity

    Directory of Open Access Journals (Sweden)

    Thomas Macaluso

    2017-10-01

    Full Text Available Understanding the impact of weightlessness on human behavior during the forthcoming long-term space missions is of critical importance, especially when considering the efficiency of goal-directed movements in these unusual environments. Several studies provided a large set of evidence that gravity is taken into account during the planning stage of arm reaching movements to optimally anticipate its consequence upon the moving limbs. However, less is known about sensorimotor changes required to face weightless environments when individuals have to perform fast and accurate goal-directed actions with whole-body displacement. We thus aimed at characterizing kinematic features of whole-body reaching movements in microgravity, involving high spatiotemporal constraints of execution, to question whether and how humans are able to maintain the performance of a functional behavior in the standards of normogravity execution. Seven participants were asked to reach as fast and as accurately as possible visual targets while standing during microgravity episodes in parabolic flight. Small and large targets were presented either close or far from the participants (requiring, in the latter case, additional whole-body displacement. Results reported that participants successfully performed the reaching task with general temporal features of movement (e.g., movement speed close to land observations. However, our analyses also demonstrated substantial kinematic changes related to the temporal structure of focal movement and the postural strategy to successfully perform -constrained- whole-body reaching movements in microgravity. These immediate reorganizations are likely achieved by rapidly taking into account the absence of gravity in motor preparation and execution (presumably from cues about body limbs unweighting. Specifically, when compared to normogravity, the arm deceleration phase substantially increased. Furthermore, greater whole-body forward displacements

  14. Intercomparison of Finnish and Russian whole-body counters used for the determination of 137Cs body burden in reindeer-herding populations

    International Nuclear Information System (INIS)

    Rahola, T.; Tillander, M.

    1995-01-01

    Intercalibration is a very important quality control in whole-body counting, as the human body is a very difficult ''sample'' to calibrate for. In 1994 the Finnish Centre for Radiation and Nuclear Safety (STUK), the Laboratory of Radiochemistry of the University of Helsinki and the Institute of Radiation Hygiene (IRH) of St. Petersburg agreed to undertake the first Finnish-Russian intercalibration project for whole-body counters. The monitoring of body burdens of indigenous inhabitants in the far north of Russia, from the Kola Peninsula to Chuhodka, has been the responsibility of the ISH since 1960; the above-.mentioned Finnish institutes have monitored reindeer breeders in Finnish Lapland since 1961. The intercalibration was done in the field by measuring the same persons with both systems in Finnish Lapland and in the Kola Peninsula. Mean body burdens in the reindeer-herding population in the areas of current interest are presented in the present paper. 7 refs., 3 figs., 1 tab

  15. Elemental transfer from Chinese soil via diet to whole human body

    International Nuclear Information System (INIS)

    Zhu Hongda; Fan Tiqiang; Wu Quan; Liu Qingfen; Zhang Wei

    2007-01-01

    Objective: To calculate elemental transfer coefficients from soil via diet to whole human body and DFs of alkaline earth and alkaline metal elements in these transfers. Methods: Based on the results in this research series, including updated values of elemental dietary intakes and whole body burdens for Chinese adult man as well quoted national elemental background values in Chinese soil, their transfer coefficients and DFs of alkaline earth and alkaline metal elements in these transfers were calculated by using UNSCEAR model and Observed Ratio Method. Results: Both the transfer coefficients of 50 elements and the DF values of alkaline earth elements with Pb and alkaline metal elements in these transfers have been obtained. Conclusion: The obtained P 23 or P 234 were all much less than P 34 for these elements. For the observed elements, the highest P 23 , P 34 and P 234 were for Hg, Ca and Se respectively, while the lowest for Ce, In and Y. The P 23 and P 234 of rare earth elements were all less than those of alkaline metal or alkaline earth elements. All of these DFs for alkaline earth elements were all smaller than 1, with increasing or decreasing atomic order, the DF values of alkaline earth elements for these transfers were successfully decreasing. The DFs of Pb seem to be between Sr and Ba. For alkaline metal element, DF of Rb or Cs from soil to diet was smaller than 1, but that from diet to whole human body more than 1. (authors)

  16. Experimental investigation of biodynamic human body models subjected to whole-body vibration during a vehicle ride.

    Science.gov (United States)

    Taskin, Yener; Hacioglu, Yuksel; Ortes, Faruk; Karabulut, Derya; Arslan, Yunus Ziya

    2018-02-06

    In this study, responses of biodynamic human body models to whole-body vibration during a vehicle ride were investigated. Accelerations were acquired from three different body parts, such as the head, upper torso and lower torso, of 10 seated passengers during a car ride while two different road conditions were considered. The same multipurpose vehicle was used during all experiments. Additionally, by two widely used biodynamic models in the literature, a set of simulations were run to obtain theoretical accelerations of the models and were compared with those obtained experimentally. To sustain a quantified comparison between experimental and theoretical approaches, the root mean square acceleration and acceleration spectral density were calculated. Time and frequency responses of the models demonstrated that neither of the models showed the best prediction performance of the human body behaviour in all cases, indicating that further models are required for better prediction of the human body responses.

  17. Modulation of the gut microbiota with antibiotic treatment suppresses whole body urea production in neonatal pigs

    DEFF Research Database (Denmark)

    Puiman, Patrycja; Stoll, Barbara; Mølbak, Lars

    2013-01-01

    We examined whether changes in the gut microbiota induced by clinically relevant interventions would impact the bioavailability of dietary amino acids in neonates. We tested the hypothesis that modulation of the gut microbiota in neonatal pigs receiving no treatment (control), intravenously...... administered antibiotics, or probiotics affects whole body nitrogen and amino acid turnover. We quantified whole body urea kinetics, threonine fluxes, and threonine disposal into protein, oxidation, and tissue protein synthesis with stable isotope techniques. Compared with controls, antibiotics reduced...... the number and diversity of bacterial species in the distal small intestine (SI) and colon. Antibiotics decreased plasma urea concentrations via decreased urea synthesis. Antibiotics elevated threonine plasma concentrations and turnover, as well as whole body protein synthesis and proteolysis. Antibiotics...

  18. The Health Effects and Keep Down of Whole Body Vibration

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2014-04-01

    Full Text Available Vibration was defined that oscillation of the body according to the reference point. The tools that are used in industry and are the source of vibration cause diseases. For this reason, the vibration has been one of the factors that affect the health and of the most widely researched in the field of ergonomics. The perceived intensity and health effects of vibration depend on the vibration frequency, intensity, direction, acceleration, duration of exposure, vibration affects the region, age, gender, posture, distance from the source person, activity, time of day and the person\\s overall health condition. The one of the most common health effects of whole body vibration is impact on musculoskeletal system. In many studies, indicated that whole-body vibration effect waist, back, shoulder and neck especially. There were varied studies that hormone levels were not changed as well there were varied studies that hormone levels were increased or decreased. There were varied studies about the digestive and circulatory system. In these studies, digestive system complaints, peptic ulcer, gastritis, varicose veins and hemorrhoids were determined frequently. For protection the health effect of vibration, Directives of the European Commission, Turkish Standards, Assessment and Management of Environmental Noise and Vibration Regulations were published. For the control of vibration are need technical and medical measures and education [TAF Prev Med Bull 2014; 13(2.000: 177-186

  19. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans

    Directory of Open Access Journals (Sweden)

    Alizé Lacoste Jeanson

    2017-05-01

    Full Text Available Background Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. Methods We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT and lean tissue (LT in such material. An intra-class correlation coefficient (ICC was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS linear regressions and support vector machine regression (SVMR. Results and Discussion The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5 and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77 than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08 for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  20. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans.

    Science.gov (United States)

    Lacoste Jeanson, Alizé; Dupej, Ján; Villa, Chiara; Brůžek, Jaroslav

    2017-01-01

    Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT) and lean tissue (LT) in such material. An intra-class correlation coefficient (ICC) was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS) linear regressions and support vector machine regression (SVMR). The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5) and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77) than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08) for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  1. Suitability of Kinect for measuring whole body movement patterns during exergaming

    NARCIS (Netherlands)

    van Diest, Mike; Stegenga, Jan; Wortche, Heinrich J.; Postema, Klaas; Verkerke, Gijsbertus J.; Lamoth, Claudine J. C.

    2014-01-01

    Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present

  2. Assessment of nutritional status in adult patients with cystic fibrosis: whole-body bioimpedance vs body mass index, skinfolds, and leg-to-leg bioimpedance

    NARCIS (Netherlands)

    Hollander, F.M.; Roos, de N.M.; Vries, de J.H.M.; Berkhout, van F.T.

    2005-01-01

    Objective: To investigate whether body mass index (BMI) or body fat percentage estimated from BMI, skinfolds, or leg-to-leg bioimpedance are good indicators of nutritional status in adult patients with cystic fibrosis. Body fat percentage measured by whole-body bioimpedance was used as the reference

  3. The whole brain diffusion tensor imaging study on acute phase of the posttraumatic stress disorder resulting from the single-prolonged stress based on tract based spatial statistics

    International Nuclear Information System (INIS)

    Xi Yibin; Liu Kang; Zhe Xia; Mu Yunfeng; Yin Hong; Huan Yi; Yang Xiaobin; Du Ping

    2013-01-01

    Objective: To study the changes of the brain white matter microstructure at the acute stage of posttraumatic stress disorder (PTSD) resulting from a single-prolonged stress. Methods: DTI scans were performed on 17 survivors buried more than 190 h in Shanxi Wangjialing mine disaster and 17 cases of normal controls using Siemens 3.0 T MR. The differences of the FA values measured from the whole brain DTI between the two groups were analyzed based on tract based spatial statistics (TBSS). FA data were statistically compared between the two groups based on nonparametric random permutation test (RPT), and the brain areas of the PTSD patients with abnormal FA were defined. Results: Compared with control group, FA values in the PTSD (at acute stage) group decreased in genu, rostral body of corpus callosum, and increased in the left thalamic and corticospinal tract region of bilateral corona radiata and the posterior limb of the left internal capsule, the left cerebral peduncle. The differences were statistically significant (P < 0.01 TFCE-corrected). Conclusions: TBSS is a comprehensive and accurate method for evaluating the changes of whole brain DTI in PTSD cases. The fiber structural abnormalities in the genu, rostral body of bilateral corpus callosum, anterior radiation of left thalamic may be due to stress. TBSS can provide a more objective basis for the early diagnosis and intervention of PTSD. (authors)

  4. A review of whole-body counting techniques appropriate to the study of gastrointestinal absorption

    International Nuclear Information System (INIS)

    Boddy, K.

    1976-01-01

    The wide range of whole-body counters in use for, or applicable to, the study of gastrointestinal absorption is reviewed. Shielded-room or high-sensitivity shadow-shield counters will generally be required only when there is a separate need to measure total body potassium or in studies involving pregnancy or children. For measuring gastrointestinal absorption per se, it is concluded that very simple whole-body counters of the shadow-shield or partial-shield type are usually satisfactory. These systems are of lower cost, and an economic justification for their use is derived by comparing their costs with those of hospitalizing patients for alternative investigations of gastrointestinal absorption. A resume of the general methodology is presented and some operational features and precautions are described. (author)

  5. Whole-body retention of 60Co incorporated into a seaweed in rats

    International Nuclear Information System (INIS)

    Inaba, Jiro; Nishimura, Yoshikazu; Ichikawa, Ryushi

    1979-01-01

    The objective of this study is to compare whole-body retention in the rat of radiocobalt incorporated into a marine green alga with that of 60 Co in inorganic form. Ulva pertusa was incubated in aerated seawater containing 60 Co under fluorescent lamp for 7 days. The radioactive seaweed was homogenated and was given to rats via a stomach tube. The control group of rats was given 60 CoCl 2 with homogenate of non-radioactive seaweed. Whole-body retention of the radionuclide was determined by in vivo counting of the living animal. The result revealed that rats absorbed and retained much more 60 Co incorporated into the seaweed than 60 CoCl 2 . This fact should be taken into account in the estimation of internal dose due to radiocobalt released into marine environment. (author)

  6. Effect of beta-hydroxy-beta-methylbutyrate (HMB) on protein metabolism in whole body and in selected tissues.

    Science.gov (United States)

    Holecek, M; Muthny, T; Kovarik, M; Sispera, L

    2009-01-01

    Beta-hydroxy-beta-methylbutyrate (HMB) is a leucine metabolite with protein anabolic effect. The aim of the study was to examine the role of exogenous HMB on leucine and protein metabolism in whole body and selected tissues. Rats were administered by HMB (0.1 g/kg b.w.) or by saline. The parameters of whole-body protein metabolism were evaluated 24 h later using L-[1-14C]leucine and L-[3,4,5-3H]phenylalanine. Changes in proteasome dependent proteolysis and protein synthesis were determined according the "chymotrypsin-like" enzyme activity and labeled leucine and phenylalanine incorporation into the protein. A decrease in leucine clearance and whole-body protein turnover (i.e., a decrease in whole-body proteolysis and protein synthesis) was observed in HMB treated rats. Proteasome-dependent proteolysis decreased significantly in skeletal muscle, changes in heart, liver, jejunum, colon, kidney, and spleen were insignificant. Decrease in protein synthesis was observed in the heart, colon, kidney, and spleen, while an increase was observed in the liver. There were no significant changes in leucine oxidation. We conclude that protein anabolic effect of HMB in skeletal muscle is related to inhibition of proteolysis in proteasome. Alterations in protein synthesis in visceral tissues may affect several important functions and the metabolic status of the whole body.

  7. Method of quantification of bone scintigraphy using technetium labelled stannous pyrophosphate. Results concerning 882 whole-body scintigraphy

    International Nuclear Information System (INIS)

    Chedeville, Rene.

    1976-01-01

    Considerable progress was made in isotope bone imaging with strontium 85 after the principle of quantification was introduced by Rosenthall in 1965. In 1971, Subramanian and McAffee reported that excellent visualization could be obtained with polyphosphates labelled with sup(99m)Tc. In the present study, imaging was performed 4 hours after injection of sup(99m)Tc pyrophosphate. An Elscint dual head wole body scanner and a VDP 2 off-line calculator were used. Counts were collected over selected regions of interest, each measuring 4.5 x 3.5 cm, and over the whole body. After checking reproducibility by double counting (SD of the mean = 15%), two methods of quantification were studied, the counts being expressed as: the ratio of the number of counts in the bone segment to the number of counts in the knee, the ratio of the number of counts in the bone segment/the number of counts in the whole body. In these operations, the whole body count was multiplied by 2.10 -3 in order to have a ratio whole body count.2.10 -3 /knee = 1. The ratios calculated from the different bone diseases under study were then compared [fr

  8. Subjective evaluation of the effectiveness of whole-body cryotherapy in patients with osteoarthritis

    Directory of Open Access Journals (Sweden)

    Tomasz Chruściak

    2016-12-01

    Full Text Available Objectives: One of the treatments for osteoarthritis (OA is whole-body cryotherapy (WBC. The aim of this study is to assess the effect of whole-body cryotherapy on the clinical status of patients with osteoarthritis (OA, according to their subjective feelings before and after the application of a 10-day cold treatment cycle. The aim is also to assess the reduction of intensity and frequency of pain, the reduction of the painkiller medication used, and to assess the possible impact on physical activity. Material and methods : The study involved 50 people, including 30 women (60% and 20 men (40%. Thirty-one patients had spondyloarthritis (62% of respondents, 10 had knee osteoarthritis (20%, and 9 hip osteoarthritis (18%. The overall average age was 50.1 ±10.9 years; the youngest patient was 29 years old and the oldest 73 years old. The average age of the women was 6 years higher. The study used a questionnaire completed by patients, and consisted of three basic parts. The modified Laitinen pain questionnaire contained questions concerning the intensity and frequency of pain, frequency of painkiller use and the degree of limited mobility. The visual analogue scale (VAS was used in order to subjectively evaluate the therapy after applying the ten-day treatment cycle. Results: According to the subjective assessment of respondents, after the whole-body cryotherapy treatments, a significant improvement occurred in 39 patients (78%, an improvement in 9 patients (18%, and no improvement was only declared by 2 patients (4%. Conclusions : Whole-body cryotherapy resulted in a reduction in the frequency and degree of pain perception in patients with osteoarthritis. WBC reduced the number of analgesic medications in these patients. It improved the range of physical activity and had a positive effect on the well-being of patients.

  9. Whole body bone scintigraphy in tenofovir-related osteomalacia: a case report

    Directory of Open Access Journals (Sweden)

    Di Biagio Antonio

    2009-07-01

    Full Text Available Abstract Introduction Tenofovir disoproxil fumarate (Viread® is the only nucleotide reverse transcriptase inhibitor currently approved for the treatment of HIV. It is frequently prescribed not only for its efficacy but also for its decreased side effect profile compared with other nucleotide analogs. In addition, it is now increasingly recognized as a cause of acquired Fanconi's syndrome in individuals with HIV. Case presentation We describe a 48-year-old woman infected with HIV, with chronic renal insufficiency, who developed Fanconi's syndrome after inclusion of tenofovir disoproxil fumarate in her antiretroviral therapy. A whole body bone scintigraphy was performed, revealing an abnormal distribution of radiotracer uptake, with characteristic changes compatible with osteomalacia. All symptoms disappeared after tenofovir discontinuation and mineral supplementation. No other explanation for the sudden and complete resolution of the bone disease was found. Conclusion The case highlights the role of whole body bone scintigraphy in the diagnosis of tenofovir-related osteomalacia.

  10. Influence of whole-body gamma irradiation upon arachidonic acid metabolism in rat platelets

    International Nuclear Information System (INIS)

    Lognonne, J.L.; Ducousso, R.; Rocquet, G.; Kergonou, J.F.

    1985-01-01

    The effects of whole-body gamma irradiation (8.4 Gy) were studied on arachidonic acid (AA) metabolism in rat's blood platelets, from day D + 1 to day D + 10 after irradiation. AA conversion into thromboxane B 2 (TxB 2 ) increased at D + 1 and then gradually decreased to very low values from D + 7 to D + 10. This decrease in the conversion of exogenous AA into TxB 2 was due to a lower AA incorporation into platelets and not to a decrease of cyclooxygenase and thromboxane-synthetase activities. AA incorporation into membrane phospholipids of blood platelets was much more decreased than AA incorporation into whole platelets; moreover, the lipid composition of the platelet membranes was markedly modified after irradiation, which must have resulted in structural and functional changes in these membranes; from these effects of whole-body gamma irradiation on platelets, the latter's membranes appeared as a major site of in vivo radiation damage in these cells

  11. Whole-Body MRI versus PET in assessment of multiple myeloma disease activity.

    LENUS (Irish Health Repository)

    Shortt, Conor P

    2009-04-01

    The purpose of this study was to compare FDG PET; whole-body MRI; and the reference standard, bone marrow aspiration and biopsy, to determine the best imaging technique for assessment of disease activity in multiple myeloma.

  12. Effects of whole-body vibration on balance and mobility in institutionalized older adults: a randomized controlled trial.

    Science.gov (United States)

    Lam, Freddy Mh; Chan, Philip Fl; Liao, L R; Woo, Jean; Hui, Elsie; Lai, Charles Wk; Kwok, Timothy Cy; Pang, Marco Yc

    2018-04-01

    To investigate whether a comprehensive exercise program was effective in improving physical function among institutionalized older adults and whether adding whole-body vibration to the program conferred additional therapeutic benefits. A single-blinded randomized controlled trial was conducted. This study was carried out in residential care units. In total, 73 older adults (40 women, mean age: 82.3 ± 7.3 years) were enrolled into this study. Participants were randomly allocated to one of the three groups: strength and balance program combined with whole-body vibration, strength and balance program without whole-body vibration, and social and recreational activities consisting of upper limb exercises only. All participants completed three training sessions per week for eight weeks. Assessment of mobility, balance, lower limb strength, walking endurance, and self-perceived balance confidence were conducted at baseline and immediately after the eight-week intervention. Incidences of falls requiring medical attention were recorded for one year after the end of the training period. A significant time × group interaction was found for lower limb strength (five-times-sit-to-stand test; P = 0.048), with the exercise-only group showing improvement (pretest: 35.8 ± 16.1 seconds; posttest: 29.0 ± 9.8 seconds), compared with a decline in strength among controls (pretest: 27.1 ± 10.4 seconds; posttest: 28.7 ± 12.3 seconds; P = 0.030). The exercise with whole-body vibration group had a significantly better outcome in balance confidence (pretest: 39.2 ± 29.0; posttest: 48.4 ± 30.6) than the exercise-only group (pretest: 35.9 ± 24.8; posttest: 38.2 ± 26.5; P = 0.033). The exercise program was effective in improving lower limb strength among institutionalized older adults but adding whole-body vibration did not enhance its effect. Whole-body vibration may improve balance confidence without enhancing actual balance performance.

  13. Whole body dosimetry for treatment individualized neuroblastoma with 131I-MIBG

    International Nuclear Information System (INIS)

    Ferrer Gracia, C.; Luquero Llopis, N.; Sanchez Munoz, F.; Plaza Aparicio, R.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    It according to in this study, that in therapy with 1 31I-MIBG for the treatment of neuroblastoma, it can prescribe and manage dose whole body accurately, allowing individualized treatments and major activities that in the treatments based on a fixed activity according to weight management. (Author)

  14. The establishment of bed type germanium-based whole body counters

    International Nuclear Information System (INIS)

    Chen, M.C.; Sun, C.L.; Yeh, W.W.

    1996-01-01

    A coaxial germanium detector was installed in a shadow-shield counter for the in-vivo measurement of γ emitters in the body. It is divided into two subparts, automatic liquid nitrogen transfer system and the Ge-based counting system. The automatic liquid nitrogen transfer system and a complete gamma spectroscopy software package were manufactured by EG and G ORTEC company. Some experiments were finished to get the optimum three setting parameters for how to operate the auto liquid nitrogen transfer system in good conditions. The filling interval should be setting at eight hours, the filling time should be setting at ten minutes, and the pressure of dewar should operate in a range from 14 to 26 PSI. The RMC-II phantom that is designed by Canberra company is used as standard man for all kinds of calibrations. The detector has resolutions that are less than 2.5 keV with an average of 1.87 keV for the 60 Co 1.33-MeV γ-ray peak. The efficiency value of thyroid geometry for four different organs is highest in the phantom. The resolution of the Germanium detector for measuring radioactivity in the body that is better than the sodium iodide detector is used to measure the internal depositions of radionuclide mixtures. So, the advantage of the germanium counter can just compensate the disadvantage of the NaI(TI) detector. The qualitative and quantitative analysis for whole body counting can keep in the best conditions if both whole body counters are operated at the same time for routine measurement purpose in the laboratory

  15. Whole body clearance of norepinephrine. The significance of arterial sampling and of surgical stress

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Madsbad, S

    1983-01-01

    The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively, in the ......The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively...

  16. Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-l-tyrosine

    International Nuclear Information System (INIS)

    Pauleit, Dirk; Floeth, Frank; Herzog, Hans; Tellmann, Lutz; Langen, Karl-J.; Hamacher, Kurt; Coenen, Heinz H.; Mueller, Hans-W.

    2003-01-01

    The whole-body distribution of O-(2-[ 18 F]fluoroethyl)-l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV ≤1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 μSv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET. (orig.)

  17. Accuracy of 24-h whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Scullion, J.E.; Bessent, R.; Cuthbert, G.F.

    1982-01-01

    The 24-h whole-body retention (WBR) of diphosphonate was a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r=0.998, R<0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. A phantom was used to assess the possible error introduced by redistribution of tracer. The net whole-body count of the phantom representing the 24-h distribution was 98% of that of a uniform phantom. Ten subjects were counted twice within a few minutes to study the effect of repositioning, and showed a mean difference between counts of only 0.8%. Eleven subjects with traumatic fractures were studied to assess the possible contribution of focal lesions to WBR. It was found that nine subjects had normal values for WBR, while two had minimally elevated results. Twenty patients with renal disease but no apparent skeletal disease were also studied to assess the possible contribution of soft-tissue retention to WBR. A significant correlation between serum creatinine and WBR was found (r=0.72, P<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/1. It is suggested that WBR measurement is accurate and the technique is hgihly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is the normal range then WBR can be assumed to reflect skeletal metabolism without further concern as to renal function. (orig.)

  18. Whole body MR in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Piekarek, A.; Sosnowski, P.; Nowicki, A.; Komarnicki, M.

    2009-01-01

    Background: Multiple myeloma is a cancer of plasma cells which leads to bone marrow infiltration. Aim: Whole-body MR is the most sensitive imaging method available to detect multiple myeloma lesions. Ma terial and methods: MR scans were performed in 100 patients with multiple myeloma who were receiving treatment in the Haematology Clinic in Poznan in the years 2005 - 2006. Whole-body MR scans were performed with general coil 1.0 T in STIR sequences and T1 sequences, in coronal and sagittal planes with scanning area covering the head, neck, trunk and the limbs (FOV for specific regions was 36 -48 cm). The bone lesions were classified as focal (monofocal/multifocal lesions), infiltrative, mixed and 'salt and pepper' type. Depending on the size of the lesions the patients were included in one of three groups according to Salmon-Durie Plus classification. Results: Four main types of multiple myeloma were distinguished based on MR scans: focal (48 patients; monofocal in 10 patients), infiltrative (17 patients), mixed type (19 patients) and 'salt and pepper' type (4 patients). The remaining 12 patients had no multiple myeloma lesions in the bone marrow. Additionally, in 18% of patients a soft tissue mass could be observed. According to Salmon-Durie Plus categorisation 27 subjects were classified as having stage I, 16 patients stage and 57 patients stage III disease. In 12% of patients MR data changed the disease staging. Conclusions: WB MR is a sensitive and effective diagnostic method with an important impact on staging and further treatment of multiple myeloma. (authors)

  19. Effects of whole-body irradiation on neonatally thymectomized mice. Incidence of benign and malignant tumors

    International Nuclear Information System (INIS)

    Anderson, R.E.; Howarth, J.L.; Troup, G.M.

    1978-01-01

    The individual and combined effects of neonatal thymectomy and whole-body irradiation on the prevalence of benign and malignant tumors in germ-free female mice of the Charles Rivers line were studied to determine if a portion of the tumorigenic effects of irradiation can be attributed to injury of the thymic-dependent component of the immune response. Neonatal thymectomy increased (a) the incidence of benign and malignant tumors and (b) the prevalence of multiple primary neoplasms in an individual mouse. Whole-body exposure to 700 rad at 6 weeks of age further increased the incidence of tumors, but the relative magnitude of this increase was less pronounced than in sham-operated controls. Thus, the cumulative effects of thymectomy plus irradiation are less pronounced than the sum of the individual effects. One of several possible explanations for this observation is that a portion of the carcinogenic effects of whole-body irradiation is mediated by suppression of the thymic-dependent component of the immune response

  20. Effect of meal and propranolol on whole body and splanchnic oxygen consumption in patients with cirrhosis

    DEFF Research Database (Denmark)

    Krag, Aleksander; Simonsen, Lene; Henriksen, Jens H

    2006-01-01

    Our aim was to measure whole body energy expenditure after a mixed liquid meal, with and without simultaneous propranolol infusion, in patients with cirrhosis. We also wanted to investigate the effect of propranolol on substrate fluxes and oxygen uptake in the tissues drained by the hepatic vein ...... as splanchnic oxygen uptake. The splanchnic reduction in oxygen consumption can explain almost the entire reduction in whole body oxygen consumption....

  1. Semi-portable whole body counter deployable during post-radiological accident

    International Nuclear Information System (INIS)

    Panchal, C.G.; Bansode, P.Y.; Vinod, M.; Sarade, Bhagyashree; Jain, R.K.; Jakati, R.K.; Pithawa, C.K.

    2012-01-01

    A versatile whole body counter with the state of art electronics has been indigenously designed and developed which can be readily deployed for use during nuclear emergency. This instrument is designed to quickly identify and quantify the activity of high energy photon emitters accumulated particularly in vital organs like thyroid, lungs besides the body of the victims of the radiological incident or accident. Special features of the instruments are swivel type detectors assembly mountable on a wall or table top and detachable collimator configurable to assess the internal contamination selectively to meet protective measures of the radiological accidents, mechanically rugged and functionally reliable to perform in contaminated environmental field conditions. (author)

  2. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  3. Effects of Arachidonic Acid Supplementation on Acute Anabolic Signaling and Chronic Functional Performance and Body Composition Adaptations.

    Directory of Open Access Journals (Sweden)

    Eduardo O De Souza

    Full Text Available The primary purpose of this investigation was to examine the effects of arachidonic acid (ARA supplementation on functional performance and body composition in trained males. In addition, we performed a secondary study looking at molecular responses of ARA supplementation following an acute exercise bout in rodents.Thirty strength-trained males (age: 20.4 ± 2.1 yrs were randomly divided into two groups: ARA or placebo (i.e. CTL. Then, both groups underwent an 8-week, 3-day per week, non-periodized training protocol. Quadriceps muscle thickness, whole-body composition scan (DEXA, muscle strength, and power were assessed at baseline and post-test. In the rodent model, male Wistar rats (~250 g, ~8 weeks old were pre-fed with either ARA or water (CTL for 8 days and were fed the final dose of ARA prior to being acutely strength trained via electrical stimulation on unilateral plantar flexions. A mixed muscle sample was removed from the exercised and non-exercised leg 3 hours post-exercise.Lean body mass (2.9%, p<0.0005, upper-body strength (8.7%, p<0.0001, and peak power (12.7%, p<0.0001 increased only in the ARA group. For the animal trial, GSK-β (Ser9 phosphorylation (p<0.001 independent of exercise and AMPK phosphorylation after exercise (p-AMPK less in ARA, p = 0.041 were different in ARA-fed versus CTL rats.Our findings suggest that ARA supplementation can positively augment strength-training induced adaptations in resistance-trained males. However, chronic studies at the molecular level are required to further elucidate how ARA combined with strength training affect muscle adaptation.

  4. Persistent changes in neuronal structure and synaptic plasticity caused by proton irradiation.

    Science.gov (United States)

    Parihar, Vipan K; Pasha, Junaid; Tran, Katherine K; Craver, Brianna M; Acharya, Munjal M; Limoli, Charles L

    2015-03-01

    Cranial radiotherapy is used routinely to control the growth of primary and secondary brain tumors, but often results in serious and debilitating cognitive dysfunction. In part due to the beneficial dose depth distributions that may spare normal tissue damage, the use of protons to treat CNS and other tumor types is rapidly gaining popularity. Astronauts exposed to lower doses of protons in the space radiation environment are also at risk for developing adverse CNS complications. To explore the consequences of whole body proton irradiation, mice were subjected to 0.1 and 1 Gy and analyzed for morphometric changes in hippocampal neurons 10 and 30 days following exposure. Significant dose-dependent reductions (~33 %) in dendritic complexity were found, when dendritic length, branching and area were analyzed 30 days after exposure. At equivalent doses and times, significant reductions in the number (~30 %) and density (50-75 %) of dendritic spines along hippocampal neurons of the dentate gyrus were also observed. Immature spines (filopodia, long) exhibited the greatest sensitivity (1.5- to 3-fold) to irradiation, while more mature spines (mushroom) were more resistant to changes over a 1-month post-irradiation timeframe. Irradiated granule cell neurons spanning the subfields of the dentate gyrus showed significant and dose-responsive reductions in synaptophysin expression, while the expression of postsynaptic density protein (PSD-95) was increased significantly. These findings corroborate our past work using photon irradiation, and demonstrate for the first time, dose-responsive changes in dendritic complexity, spine density and morphology and synaptic protein levels following exposure to low-dose whole body proton irradiation.

  5. Inhibitory mechanism of low-dose, whole-body irradiation with gamma-rays against tumor metastasis

    International Nuclear Information System (INIS)

    Yasuhiro Ohsima; Mitsutoshi Tukimoto; Shuji Kojima

    2007-01-01

    Complete text of publication follows. A lot of beneficial effects of low-dose irradiation are well known. Of them, an inhibitory effect of the radiation on lung metastasis is reported so far. It has been reported that low-dose whole-body irradiation with gamma rays enhanced cytotoxic immune response as one of the mechanisms. In our laboratory, it has been confirmed an enhancement of natural killer activity in mice irradiated with whole-body 0.5Gy gamma-rays. Metastasis is accomplished by multistep process, involving basement membrane destruction, local invasion, intravasation, survival in the bloodstream, extravasation into distant organs, and proliferation at the target site. Besides, a lot of growth factors and proteases are involved in these steps. As to mechanism of inhibition of tumor metastasis induced by low-dose whole-body irradiation, studies from the standpoint of tumor invasion have not been reported. Here, inhibitory effect of 0.5Gy whole-body gamma-ray irradiation on tumor metastasis and its mechanism were examined in pulmonary metastasis model mice injected with B16 melanoma cells. Consequently, 0.5Gy whole-body gamma ray irradiation significantly suppressed colony formation in the lungs. Expression of matrix metalloproteinase- 2 (MMP- 2), a proteinase related to metastasis, in lung tissues was suppressed by the radiation. Alteration of tissue inhibitor of matrix metalloproteinase (TIMP) after the gamma-ray irradiation was examined. Expression of TIMP-1 and TIMP-2 mRNA in the lungs were significantly increased. In order to clarify the inhibitory effect obtained in the in vivo metastatic lung cancer model mice, we studied effects of gamma-rays on cell proliferation, alterations of mRNA and proteins related to tumor metastasis in cultured B16 melanoma cells. Proliferation of B16 melanoma cells was decreased in a dose-dependent manner. MMP-2 mRNA expression was not altered in any doses of gamma-rays. Thought expression of the protein was slightly

  6. Open-Ended Measurement of Whole-Body Movement: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Finn, Michael T. M.

    2018-02-01

    Full Text Available As the importance of embodiment emerges for psychology, there is a need to advance methodology for measuring the dynamics of movement in an open-ended fashion. Such a tool should be versatile across contexts and track spontaneous and natural movement with minimal constraints. We test the feasibility of a method for measuring whole-body movement over time that attempts to meet this need. We use a motion capture system comprised of two Microsoft Kinect version 2.0 cameras and iPiSoft Motion Capture software, and compare its estimates of magnitude rotational velocity and whole-body movement complexity (multivariate multiscale sample entropy; MMSE to that of a gold standard motion capture system across a variety of movement sequences. The candidate system satisfactorily estimated the instantaneous velocity of 13 body segments in agreement with the gold standard system across movement sequences demonstrating initial feasibility of this process. Summary calculations of velocity by sequence and MMSE calculations were also in high agreement with the gold standard, crucially suggesting that the candidate system could pick up on the complex dynamics of movement over time. The candidate system was feasible and demonstrates preliminary validity for general use in the tracking of continuous human movement for clinical and experimental psychology. We also provide R code and sample data for the importing and processing of movement data exported from iPiSoft Motion Capture Studio.

  7. Effects of whole body UV-irradiation on oxygen delivery from the erythrocyte

    International Nuclear Information System (INIS)

    Humpeler, E.; Mairbaeurl, H.; Hoenigsmann, H.

    1982-01-01

    In 16 healthy caucasian volunteers (mean age: 22.2 years) the influence of whole body UV-irradiation on the oxygen transport properties of erythrocytes was investigated. Four hours after irradiation with UV (using the minimal erythema dose, MED) no variation of haemoglobin concentration, hematocrit, mean corpuscular haemoglobin concentration, pH or standard bicarbonate could be found, whereas inorganic plasma phosphate (Psub(i)), calcium, the intraerythrocytic 2,3-diphosphoglycerate (2,3-DPG), the activity of erythrocytic phosphofructokinase (PFK) and pyruvatekinase (PK) increased significantly. The half saturation tension of oxygen (P 50 -value) tended to increase. The increase of Psub(i) causes - via a stimulation of the glycolytic pathway - an increase in 2,3-DPG concentration and thus results in a shift of the oxygen dissociation curve. It is therefore possible to enhance tissue oxygenation by whole body UV-irradiation. (orig.)

  8. Start up of the whole body detection system

    International Nuclear Information System (INIS)

    Cortes P, A.; Angeles C, A.; Cuapio O, A.; Tejera R, A.

    1991-12-01

    The management of Radiological Safety of the Nuclear Center of Mexico has a whole body detection system Trade mark Canberra, manufactured by Bio-nuclear Measurements Inc. Ipswich Massachusetts. These systems are used to detect contamination of I-131 in thyroid and other nuclides (Cs-137, Cs-134, Co-60, etc.) in thorax. In this work the procedure that was continued for the setting in march of the thyroid detector is presented. A description of this system and an analysis of the uncertainties involved in the measures of activity of I-131 in thyroid of people occupationally exposed is made. (Author)

  9. Whole body BMC in pediatric Crohn disease: independent effects of altered growth, maturation, and body composition.

    Science.gov (United States)

    Burnham, Jon M; Shults, Justine; Semeao, Edisio; Foster, Bethany; Zemel, Babette S; Stallings, Virginia A; Leonard, Mary B

    2004-12-01

    Whole body BMC was assessed in 104 children and young adults with CD and 233 healthy controls. CD was associated with significant deficits in BMC and lean mass, relative to height. Adjustment for lean mass eliminated the bone deficit in CD. Steroid exposure was associated with short stature but not bone deficits relative to height. Children with Crohn disease (CD) have multiple risk factors for impaired bone accrual. The confounding effects of poor growth and delayed maturation limit the interpretation of prior studies of bone health in CD. The objective of this study was to assess BMC relative to growth, body composition, and maturation in CD compared with controls. Whole body BMC and lean mass were assessed by DXA in 104 CD subjects and 233 healthy controls, 4-26 years of age. Multivariable linear regression models were developed to sequentially adjust for differences in skeletal size, pubertal maturation, and muscle mass. BMC-for-height z scores were derived to determine CD-specific covariates associated with bone deficits. Subjects with CD had significantly lower height z score, body mass index z score, and lean mass relative to height compared with controls (all p BMC in CD relative to controls was significantly reduced in males (0.86; 95% CI, 0.83, 0.94) and females (0.91; 95% CI, 0.85, 0.98) with CD. Adjustment for pubertal maturation did not alter the estimate; however, addition of lean mass to the model eliminated the bone deficit. Steroid exposure was associated with short stature but not bone deficits. This study shows the importance of considering differences in body size and composition when interpreting DXA data in children with chronic inflammatory conditions and shows an association between deficits in muscle mass and bone in pediatric CD.

  10. Real-time stylistic prediction for whole-body human motions.

    Science.gov (United States)

    Matsubara, Takamitsu; Hyon, Sang-Ho; Morimoto, Jun

    2012-01-01

    The ability to predict human motion is crucial in several contexts such as human tracking by computer vision and the synthesis of human-like computer graphics. Previous work has focused on off-line processes with well-segmented data; however, many applications such as robotics require real-time control with efficient computation. In this paper, we propose a novel approach called real-time stylistic prediction for whole-body human motions to satisfy these requirements. This approach uses a novel generative model to represent a whole-body human motion including rhythmic motion (e.g., walking) and discrete motion (e.g., jumping). The generative model is composed of a low-dimensional state (phase) dynamics and a two-factor observation model, allowing it to capture the diversity of motion styles in humans. A real-time adaptation algorithm was derived to estimate both state variables and style parameter of the model from non-stationary unlabeled sequential observations. Moreover, with a simple modification, the algorithm allows real-time adaptation even from incomplete (partial) observations. Based on the estimated state and style, a future motion sequence can be accurately predicted. In our implementation, it takes less than 15 ms for both adaptation and prediction at each observation. Our real-time stylistic prediction was evaluated for human walking, running, and jumping behaviors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. A preliminary study of iron absorption by whole body counting and correlation with DFO excretion

    International Nuclear Information System (INIS)

    Gupta, M.M.; Bhattacharyya, L.; Gupta, N.K.; Bhola, G.C.; Nagaratnam, A.; Manchanda, R.; Bhargva, M.; Kumar, S.

    1975-01-01

    A preliminary study of iron absorption by oral administration of 59 Fe and whole body counting was carried on a group of 16 women. The cases included 8 patients suffering from iron deficiency anaemia and various infections as well as 8 healthy controls. High iron absorption is associated with iron deficiency, these changes being more marked in iron deficient controls than in those with infection or malignancy. In iron deficient controls results of whole body counting correlate very well with other haematological investigations. (orig.) [de

  12. Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics

    DEFF Research Database (Denmark)

    Maroy, Renaud; Boisgard, Raphaël; Comtat, Claude

    2008-01-01

    Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new...... method for the segmentation of rodent whole-body PET images that takes these two difficulties into account by estimating the pharmacokinetics far from organ borders. The segmentation method proved efficient on whole-body numerical rat phantom simulations, including 3-14 organs, together...

  13. Various performance-enhancing effects from the same intensity of whole-body vibration training

    Directory of Open Access Journals (Sweden)

    Paohung Chung

    2017-09-01

    Conclusion: All frequency and amplitude settings in the 8-week whole-body vibration training increased muscle strength, but different settings resulted in various neuromuscular adaptations despite the same intensity.

  14. Acute dim light at night increases body mass, alters metabolism, and shifts core body temperature circadian rhythms.

    Science.gov (United States)

    Borniger, Jeremy C; Maurya, Santosh K; Periasamy, Muthu; Nelson, Randy J

    2014-10-01

    The circadian system is primarily entrained by the ambient light environment and is fundamentally linked to metabolism. Mounting evidence suggests a causal relationship among aberrant light exposure, shift work, and metabolic disease. Previous research has demonstrated deleterious metabolic phenotypes elicited by chronic (>4 weeks) exposure to dim light at night (DLAN) (∼ 5 lux). However, the metabolic effects of short-term (dim light would gain more body mass, alter whole body metabolism, and display altered body temperature (Tb) and activity rhythms compared to mice maintained in dark nights. Our data largely support these predictions; DLAN mice gained significantly more mass, reduced whole body energy expenditure, increased carbohydrate over fat oxidation, and altered temperature circadian rhythms. Importantly, these alterations occurred despite similar activity locomotor levels (and rhythms) and total food intake between groups. Peripheral clocks are potently entrained by body temperature rhythms, and the deregulation of body temperature we observed may contribute to metabolic problems due to "internal desynchrony" between the central circadian oscillator and temperature sensitive peripheral clocks. We conclude that even relatively short-term exposure to low levels of nighttime light can influence metabolism to increase mass gain.

  15. Cold-water acclimation does not modify whole-body fluid regulation during subsequent cold-water immersion.

    Science.gov (United States)

    Stocks, J M; Patterson, M J; Hyde, D E; Jenkins, A B; Mittleman, K D; Taylor, N A S

    2004-06-01

    We investigated the impact of cold-water acclimation on whole-body fluid regulation using tracer-dilution methods to differentiate between the intracellular and extracellular fluid compartments. Seven euhydrated males [age 24.7 (8.7) years, mass 74.4 (6.4) kg, height 176.8 (7.8) cm, sum of eight skinfolds 107.4 (20.4) mm; mean (SD)] participated in a 14-day cold-water acclimation protocol, with 60-min resting cold-water stress tests [CWST; 18.1 (0.1) degrees C] on days 1, 8 and 15, and 90-min resting cold-water immersions [18.4 (0.4) degrees C] on intervening days. Subjects were immersed to the 4th intercostal space. Intracellular and extracellular fluid compartments, and plasma protein, electrolyte and hormone concentrations were investigated. During the first CWST, the intracellular fluid (5.5%) and plasma volumes were reduced (6.1%), while the interstitial fluid volume was simultaneously expanded (5.4%). This pattern was replicated on days 8 and 15, but did not differ significantly among test days. Acclimation did not produce significant changes in the pre-immersion distribution of total body water, or changes in plasma osmolality, total protein, electrolyte, atrial natriuretic peptide or aldosterone concentrations. Furthermore, a 14-day cold-water acclimation regimen did not elicit significant changes in body-fluid distribution, urine production, or the concentrations of plasma protein, electrolytes or the fluid-regulatory hormones. While acclimation trends were not evident, we have confirmed that fluid from extravascular cells is displaced into the interstitium during acute cold-water immersion, both before and after cold acclimation.

  16. Effect of age and body weight on toxicity and survival in pediatric acute myeloid leukemia

    DEFF Research Database (Denmark)

    Løhmann, Ditte J A; Abrahamsson, Jonas; Ha, Shau-Yin

    2016-01-01

    Treatment for pediatric acute myeloid leukemia is very toxic and the association between outcome and age and Body Mass Index is unclear. We investigated effect of age and Body Mass Index on toxicity and survival in pediatric acute myeloid leukemia. We studied all patients who completed first...

  17. USTUR WHOLE BODY CASE 0269: DEMONSTRATING EFFECTIVENESS OF I.V. CA-DTPA FOR PU

    Energy Technology Data Exchange (ETDEWEB)

    James, Anthony C.; Sasser , Lyle B.; Stuit, Dorothy B.; Glover, Samuel E.; Carbaugh, Eugene H.

    2008-01-28

    This whole body donation case (USTUR Registrant) involved a single acute inhalation of an acidic Pu(NO3)4 solution in the form of an aerosol ‘mist.’ Chelation treatment with i.v. Ca-EDTA was initiated on the day of the intake, and continued intermittently over 6 months. After 2½ years with no further treatment, a course of i.v. Ca-DTPA was administered. A total of 400 measurements of 239+240Pu excreted in urine were recorded; starting on the first day (both before and during the initial Ca-EDTA chelation), and continuing for 37 years. This sampling included all intervals of chelation. In addition, 91 measurements of 239+240Pu-in-feces were recorded over this whole period. The Registrant died about 38 years after the intake, at age 79 y, with extensive carcinomatosis secondary to adenocarcinoma of the prostate gland. At autopsy, all major soft tissue organs were harvested for radiochemical analyses of their 238Pu, 239+240Pu and 241Am content. Also, all types of bone (comprising about half the skeleton) were harvested for radiochemical analyses, as well as samples of skin, subcutaneous fat and muscle. This comprehensive dataset has been applied to derive ‘chelation-enhanced’ transfer rates in the ICRP Publication 67 plutonium biokinetic model, representing the behaviour of blood-borne and tissue-incorporated plutonium during intervals of therapy. The resulting model of the separate effects of i.v. Ca-EDTA and Ca-DTPA chelation shows that the therapy administered in this case succeeded in reducing substantially the long-term burden of plutonium in all body organs, except for the lungs. The calculated reductions in organ content at the time of death are approximately 40% for the liver, 60% for other soft tissues (muscle, skin, glands, etc.), 50% for the kidneys, and 50% for the skeleton. Essentially all of the substantial reduction in skeletal burden occurred in trabecular bone. This modeling exercise demonstrated that 3-y-delayed Ca-DTPA therapy was as

  18. Numerical analysis of whole-body cryotherapy chamber design improvement

    Science.gov (United States)

    Yerezhep, D.; Tukmakova, A. S.; Fomin, V. E.; Masalimov, A.; Asach, A. V.; Novotelnova, A. V.; Baranov, A. Yu

    2018-05-01

    Whole body cryotherapy is a state-of-the-art method that uses cold for treatment and prevention of diseases. The process implies the impact of cryogenic gas on a human body that implements in a special cryochamber. The temperature field in the chamber is of great importance since local integument over-cooling may occur. Numerical simulation of WBC has been carried out. Chamber design modification has been proposed in order to increase the uniformity of the internal temperature field. The results have been compared with the ones obtained for a standard chamber design. The value of temperature gradient formed in the chamber containing curved wall with certain height has been decreased almost twice in comparison with the results obtained for the standard design. The modification proposed may increase both safety and comfort of cryotherapy.

  19. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  20. Intermittent fasting does not affect whole-body glucose, lipid, or protein metabolism

    NARCIS (Netherlands)

    Soeters, Maarten R.; Lammers, Nicolette M.; Dubbelhuis, Peter F.; Ackermans, Mariëtte T.; Jonkers-Schuitema, Cora F.; Fliers, Eric; Sauerwein, Hans P.; Aerts, Johannes M.; Serlie, Mireille J.

    2009-01-01

    Background: Intermittent fasting (IF) was shown to increase whole-body insulin sensitivity, but it is uncertain whether IF selectively influences intermediary metabolism. Such selectivity might be advantageous when adapting to periods of food abundance and food shortage. Objective: The objective was

  1. Metal uptake and acute toxicity in zebrafish: Common mechanisms across multiple metals

    Energy Technology Data Exchange (ETDEWEB)

    Alsop, Derek, E-mail: alsopde@mcmaster.ca [Department of Biology, McMaster University, 1280 Main St. W., Hamilton, ON L8S 4K1 (Canada); Wood, Chris M. [Department of Biology, McMaster University, 1280 Main St. W., Hamilton, ON L8S 4K1 (Canada)

    2011-10-15

    All metals tested reduced calcium uptake in zebrafish larvae. However, it was whole body sodium loss that was functionally related to toxicity. The zebrafish larvae acute toxicity assay save time, space and resources. - Abstract: Zebrafish larvae (Danio rerio) were used to examine the mechanisms of action and acute toxicities of metals. Larvae had similar physiological responses and sensitivities to waterborne metals as adults. While cadmium and zinc have previously been shown to reduce Ca{sup 2+} uptake, copper and nickel also decreased Ca{sup 2+} uptake, suggesting that the epithelial transport of all these metals is through Ca{sup 2+} pathways. However, exposure to cadmium, copper or nickel for up to 48 h had little or no effect on total whole body Ca{sup 2+} levels, indicating that the reduction of Ca{sup 2+} uptake is not the acute toxic mechanism of these metals. Instead, mortalities were effectively related to whole body Na{sup +}, which decreased up to 39% after 48 h exposures to different metals around their respective 96 h LC50s. Decreases in whole body K{sup +} were also observed, although they were not as pronounced or frequent as Na{sup +} losses. None of the metals tested inhibited Na{sup +} uptake in zebrafish (Na{sup +} uptake was in fact increased with exposure) and the observed losses of Na{sup +}, K{sup +}, Ca{sup 2+} and Mg{sup 2+} were proportional to the ionic gradients between the plasma and water, indicating diffusive ion loss with metal exposure. This study has shown that there is a common pathway for metal uptake and a common mechanism of acute toxicity across groups of metals in zebrafish. The disruption of ion uptake accompanying metal exposure does not appear to be responsible for the acute toxicity of metals, as has been previously suggested, but rather the toxicity is instead due to total ion loss (predominantly Na{sup +}).

  2. Changes in serum 25-hydroxyvitamin D and cholecalciferol after one whole-body exposure in a commercial tanning bed

    DEFF Research Database (Denmark)

    Langdahl, Jacob H; Schierbeck, Louise Lind; Bang, Ulrich Christian

    2012-01-01

    We wanted to evaluate the cutaneous synthesis of 25OHD and cholecalciferol after one whole-body exposure to ultraviolet radiation type B (UVB) in a randomized setup. Healthy volunteers were randomized to one whole-body exposure in a commercial tanning bed with UVB emission (UVB/UVA ratio 1...

  3. Influence of Tire Characteristics of Interurban Taxis on Exposure Level to Drivers Whole-Body Vibrations

    Directory of Open Access Journals (Sweden)

    Milad Derakhshanjazari

    2016-03-01

    Full Text Available Introduction: Taxi drivers’ exposure to repeat whole-body vibrations can cause back pain and digestive disorders. Since this type of vibration depends on the car components, this study was carried out to determine the influence of tire characteristics on the amount of whole-body vibrations transmitted to the Peugeot 405 taxi drivers. Methods: In this experimental study, vibration characteristics were measured according to the ISO2631-1 with each of the statuses: tubeless tires fixed and fluid in it (normal air or nitrogen and also the fluid in the tires fixed with tubes or tubeless on asphalt-paved road. Other variables including tire pressure, engine speed, road gradient, number of passengers, springs, and shock absorbers were kept constant. Then the effect of changes was analyzed using an appropriate statistical test. Results: After changing nitrogen to normal air and tubeless tires to tube, the average of RMS in Z-axis, eight-hour equivalent acceleration A(8 and crest factor were reduced (P 0.9 m/s2 to caution zone (0.45-0.9 m/s2 with a value of 0.8 m/s2. Conclusions: The amount of vibration transmitted to the whole body is sensitive to existence of tubes and tires inflation so that we can reduce the amount of whole-body vibration to lower than the upper limit of the health risk by changing the characteristics of the tire

  4. WHOLE BODY VIBRATION IMPROVES ATTENTION AND MOTOR PERFORMANCE IN MICE DEPENDING ON THE DURATION OF THE WHOLE-BODY VIBRATION SESSION.

    Science.gov (United States)

    Keijser, Jan N; van Heuvelen, Marieke J G; Nyakas, Csaba; Tóth, Kata; Schoemaker, Regien G; Zeinstra, Edzard; van der Zee, Eddy A

    2017-01-01

    Whole body vibration (WBV) is a form of physical stimulation via mechanical vibrations transmitted to a subject. It is assumed that WBV induces sensory stimulation in cortical brain regions through the activation of skin and muscle receptors responding to the vibration. The effects of WBV on muscle strength are well described. However, little is known about the impact of WBV on the brain. Recently, it was shown in humans that WBV improves attention in an acute WBV protocol. Preclinical research is needed to unravel the underlying brain mechanism. As a first step, we examined whether chronic WBV improves attention in mice. A custom made vibrating platform for mice with low intensity vibrations was used. Male CD1 mice (3 months of age) received five weeks WBV (30 Hz; 1.9 G), five days a week with sessions of five (n=12) or 30 (n=10) minutes. Control mice (pseudo-WBV; n=12 and 10 for the five and 30 minute sessions, respectively) were treated in a similar way, but did not receive the actual vibration. Object recognition tasks were used as an attention test (novel and spatial object recognition - the primary outcome measure). A Balance beam was used for motor performance, serving as a secondary outcome measure. WBV sessions of five (but not WBV sessions of 30 minutes) improved balance beam performance (mice gained 28% in time needed to cross the beam) and novel object recognition (mice paid significantly more attention to the novel object) as compared to pseudo WBV, but no change was found for spatial object performance (mice did not notice the relocation). Although 30 minutes WBV sessions were not beneficial, it did not impair either attention or motor performance. These results show that brief sessions of WBV improve, next to motor performance, attention for object recognition, but not spatial cues of the objects. The selective improvement of attention in mice opens the avenue to unravel the underlying brain mechanisms.

  5. Relevance of whole body vibration exercise in sport: a short review ...

    African Journals Online (AJOL)

    Background: Whole body vibration exercise (WBVE) has been used as a safe and accessible exercise and important reviews have been published about the use of this exercise to manage diseases and to improve physical conditions of athletes The aim of this paper is to highlight the relevance of WBVE to soccer players, ...

  6. Biochemical and muscle studies in patients with acute onset post-viral fatigue syndrome.

    OpenAIRE

    Preedy, V R; Smith, D G; Salisbury, J R; Peters, T J

    1993-01-01

    AIMS--To investigate in detail various biochemical and pathophysiological indices of muscle pathology in acute onset post-viral fatigue syndrome (PVFS). METHODS--Twenty three patients with PVFS (of mean duration 4.6 years) were subjected to needle biopsy for histomorphometry and total RNA contents. Plasma analysis included serology and creatine kinase activities. Indices of whole body mass were also measured--namely, whole body potassium content and plasma carnosinase activities. RESULTS--Abo...

  7. Stochastic resonance whole-body vibration improves postural control in health care professionals: a worksite randomized controlled trial.

    Science.gov (United States)

    Elfering, Achim; Schade, Volker; Stoecklin, Lukas; Baur, Simone; Burger, Christian; Radlinger, Lorenz

    2014-05-01

    Slip, trip, and fall injuries are frequent among health care workers. Stochastic resonance whole-body vibration training was tested to improve postural control. Participants included 124 employees of a Swiss university hospital. The randomized controlled trial included an experimental group given 8 weeks of training and a control group with no intervention. In both groups, postural control was assessed as mediolateral sway on a force plate before and after the 8-week trial. Mediolateral sway was significantly decreased by stochastic resonance whole-body vibration training in the experimental group but not in the control group that received no training (p < .05). Stochastic resonance whole-body vibration training is an option in the primary prevention of balance-related injury at work. Copyright 2014, SLACK Incorporated.

  8. Turnover of whole body proteins and myofibrillar proteins in middle-aged active men

    International Nuclear Information System (INIS)

    Zackin, M.; Meredith, C.; Frontera, W.; Evans, W.

    1986-01-01

    Endurance-trained older men have a higher proportion of lean tissue and greater muscle cell oxidative capacity, reversing age-related trends and suggesting major changes in protein metabolism. In this study, protein turnover was determined in 6 middle-aged (52+/-1 yr) men who were well trained (VO 2 max 55.2+/-5.0 ml O 2 /kg.min) and lean (body fat 18.9+/-2.8%, muscle mass 36.6+/-0.6%). The maintained habitual exercise while consuming 0.6, 0.9 or 1.2 g protein/kg.day for 10-day periods. N flux was measured from 15 N in urea after oral 15 N-glycine administration. Myofibrillar protein breakdown was estimated from urinary 3-methyl-histidine. Dietary protein had no effect on turnover rates, even when N balance was negative. Whole body protein synthesis was 3.60+/-0.12 g/kg.day and breakdown was 3.40+/-0.14 g/kg.day for all N intakes. Whole body protein flux, synthesis and breakdown were similar to values reported for sedentary young (SY) or sedentary old (SO) men on comparable diets. 3-me-his (3.67+/-0.14 μmol/kg.day) was similar to values reported for SY but higher (p<0.01) than for SO. Myofibrillar protein breakdown per unit muscle mass (185+/-7 μmol 3-me-his/g creatinine) was higher (p<0.01) than for SY or SO. In active middle-aged men, myofibrillar proteins may account for a greater proportion of whole body protein turnover, despite an age-related reduction in muscle mass

  9. Whole body computed tomographic findings of each one case with primary aldosteronism and Cushing syndrome

    International Nuclear Information System (INIS)

    Kamata, Shuji; Kawamura, Koro; Nakamura, Motoyuki

    1980-01-01

    We here report each one case with primary aldosteronism (male, 28 years old) and Cushing syndrome (female, 37 years old). Both of the cases showed characteristic clinical signs of hypertension and typical laboratory findings of adreno-hormonal assays. In performance of whole body computed tomography, clear pictures of tumorous adenomas in both cases were taken and the sizes of adenomas in picture were completely same as the masses obtained by the lateral adrenectomies. As a result, the whole body computed tomography is very useful to diagnose the diseases of adrenal adenoma and hyperplasia. (author)

  10. Estimation of whole body dose in an unusual event: spillage of radioactive material on the chair

    International Nuclear Information System (INIS)

    Adtani, M.M.; Biju, K.; Deshpande, M.D.; Shivde, R.K.; Kulkarni, V.V.

    2005-01-01

    The personnel monitoring in India is done using thermoluminescence dosimeters worn at chest level. In research institutions and in nuclear facilities where radiation sources are processed in dispersible forms, a remote possibility exists that radiation source entering in the area where installed monitor does not exist and the source may get spilled on chair and causing exposure to persons sitting on the chair. In such case TLD may not give the correct exposure as there is shielding of individuals body. An attempt is made to find out a factor for estimating the whole body dose by knowing the TLD badge dose or by measuring the gonad dose. Experiments are performed using TLDs and also measurement by teletector. Monte Carlo simulations are also done. It is observed that a factor of 8 to TLD Badge dose will give whole body dose if worker has received dose only on said chair or by applying a factor of 0.23 to dose measured at gonad level will give whole body dose. (author)

  11. Conversion of a whole-body counter into a low-level whole-body scanning system controlled by a process computer

    International Nuclear Information System (INIS)

    Hamann, C.M.

    1976-01-01

    The report outlines the status of a research project in which a whole body counter with fixed geometries is converted into a scanning type system. The purpose of the project is the development of an adaptive system controlled by a process computer. The home-made scanning mechanics is explained, and a description is given of the advantages and the problems inherent in the application of step motors. For economic reasons no CAMAC system was purchased; instead, interfaces from and to the computer were designed which allowed the process periphery to be connected and operated. The inexpensive and relatively simple home-made designs are outlined; the example quoted refers to the conversion of a teletype output into a fast electronic data interface. (orig./ORU) [de

  12. Acute silver toxicity in aquatic animals is a function of sodium uptake rate

    DEFF Research Database (Denmark)

    Bianchini, A.; Grosell, Martin Hautopp; Gregory, S.

    2002-01-01

    -specific surface area of the gills depends on animal body mass; and (iv) the gill surface is also the major site of Na+ loss by diffusion, we hypothesized that whole body Na+ uptake rate (i.e., turnover rate) and secondarily body mass would be good predictors of acute silver toxicity. Results obtained from...... toxicological (LC50 of AgNO3) and physiological (22Na uptake rate) tests performed on juvenile fish (rainbow trout, Oncorhynchus mykiss), early juvenile and adult crayfish (Cambarus diogenes diogenes), and neonate and adult daphnids (Daphnia magna) in moderately hard water of constant quality support the above...... hypothesis. Therefore, sensitivity to AgNO3, in terms of either total measured silver or free Ag+, was reliably predicted from the whole body Na+ uptake rate in animals with body mass ranging over 6 orders of magnitude (from micrograms to grams). A positive log-log correlation between acute AgNO3 toxicity...

  13. Identification of Motive Forces on the Whole Body System during Walking

    Directory of Open Access Journals (Sweden)

    Raghdan J. AlKhoury

    2010-01-01

    Full Text Available Motive forces by muscles are applied to different parts of the human body in a periodic fashion when walking at a uniform rate. In this study, the whole human body is modeled as a multidegree of freedom (MDOF system with seven degrees of freedom. In view of the changing contact conditions with the ground due to alternating feet movements, the system under study is considered piecewise time invariant for each half-period when one foot is in contact with the ground. Forces transmitted from the body to the ground while walking at a normal pace are experimentally measured and numerically simulated. Fourth-order Runge-Kutta method is employed to numerically simulate the forces acting on different masses of the body. An optimization problem is formulated with the squared difference between the measured and simulated forces transmitted to the ground as the objective function, and the motive forces on the body masses as the design variables to solve.

  14. A refined method for assessing sup(99m)Tc-MDP whole body retention in prostate cancer patients

    International Nuclear Information System (INIS)

    Castronovo, F.P. Jr.; Strauss, H.W.; McKusick, K.A.

    1987-01-01

    Whole body retention (WBR) of sup(99m)Tc labeled methylene diphosphonate (MDP) significantly differentiates various clinical stages of prostate cancer. Whole body measurements, when performed at 5 min and 24 h after i.v. administration of sup(99m)Tc-MDP, allows for the calculations of percentage whole body retention (% WBR) after one day. In an attempt to better describe the clinical course of prostate cancer patients with bone metastases we have refined the % WBR calculations to include a normalization factor. The latter consists of the mean 24-h value of WBR's as obtained from 10 prostate cancer patients without bony metastases as determined by bone scintigram. The % WBR is then divided by the normalization factor of choice and expressed as (% WRN)sup(N). These data are used to better express sup(99m)Tc MDP 24-h whole body retentions when following the clinical course of patients with metastatic carcinoma of the prostate. Caution should be exercised when interpreting these data when metabolic bone pathology is present. A false negative (% WBR)sup(N) value will result if an infiltration of the sup(99m)Tc-MDP occurs during administration. (author)

  15. Quantification of whole-body bradykinesia in Parkinson's disease participants using multiple inertial sensors.

    Science.gov (United States)

    Memar, Sara; Delrobaei, Mehdi; Pieterman, Marcus; McIsaac, Kenneth; Jog, Mandar

    2018-04-15

    Bradykinesia (slowness of movement) is a common motor symptom of Parkinson's disease (PD) that can severely affect quality of life for those living with the disease. Assessment and treatment of PD motor symptoms largely depends on clinical scales such as the Unified Parkinson's Disease Rating Scale (UPDRS). However, such clinical scales rely on the visual assessment by a human observer, naturally resulting in inter-rater variability. Although previous studies have developed objective means for measuring bradykinesia in PD patients, their evaluation was restricted by the type of movement and number of joints assessed. These studies failed to provide a more comprehensive, whole-body evaluation capable of measuring multiple joints simultaneously. This study utilizes wearable inertial measurement units (IMUs) to quantify whole-body movements, providing novel bradykinesia indices for walking (WBI) and standing up from a chair (sit-to-stand; SBI). The proposed bradykinesia indices include the joint angles at both upper and lower limbs and trunk motion to compute a complete, objective score for whole body bradykinesia. Thirty PD and 11 age-matched healthy control participants were recruited for the study. The participants performed two standard walking tasks that involved multiple body joints in the upper and lower limbs. The WBI and SBI successfully identified differences between control and PD participants. The indices also effectively identified differences within the PD population, distinguishing participants assessed with (ON) and without (OFF) levodopa; the gold-standard of treatment for PD. The goal of this study is to provide health professionals with an objective score for whole body bradykinesia by simultaneously measuring the upper and lower extremities along with truncal movement. This method demonstrates potential to be used in conjunction with current clinical standards for motor symptom assessment, and may also be promising for the remote assessment of PD

  16. Vestibular-somatosensory interactions: effects of passive whole-body rotation on somatosensory detection.

    Directory of Open Access Journals (Sweden)

    Elisa Raffaella Ferrè

    Full Text Available Vestibular signals are strongly integrated with information from several other sensory modalities. For example, vestibular stimulation was reported to improve tactile detection. However, this improvement could reflect either a multimodal interaction or an indirect interaction driven by vestibular effects on spatial attention and orienting. Here we investigate whether natural vestibular activation induced by passive whole-body rotation influences tactile detection. In particular, we assessed the ability to detect faint tactile stimuli to the fingertips of the left and right hand during spatially congruent or incongruent rotations. We found that passive whole-body rotations significantly enhanced sensitivity to faint shocks, without affecting response bias. Critically, this enhancement of somatosensory sensitivity did not depend on the spatial congruency between the direction of rotation and the hand stimulated. Thus, our results support a multimodal interaction, likely in brain areas receiving both vestibular and somatosensory signals.

  17. Association between body water status and acute mountain sickness.

    Directory of Open Access Journals (Sweden)

    Hannes Gatterer

    Full Text Available PURPOSE: The present study determined the association between body fluid variation and the development of acute mountain sickness (AMS in adults. METHODS: Forty-three healthy participants (26 males and 17 females, age: 26 ± 6 yr, height: 174 ± 9 cm, weight: 68 ± 12 kg were passively exposed at a FiO2 of 12.6% (simulated altitude hypoxia of 4500 m, PiO2 = 83.9 mmHg for 12-h. AMS severity was assessed using the Lake Louise Score (LLS. Food and drink intakes were consumed ad libitum and measured; all urine was collected. Before and after the 12-h exposure, body weight and plasma osmolality were measured and whole-body bioimpedance analysis was performed. RESULTS: The overall AMS incidence was 43% (38% males, 50% females. Participants who developed AMS showed lower fluid losses (3.0 ± 0.9 vs. 4.5 ± 2.0 ml/kg/h, p = 0.002, a higher fluid retention (1.9 ± 1.5 vs. 0.6 ± 0.8 ml/kg/h, p = 0.022, greater plasma osmolality decreases (-7 ± 7 vs. -2 ± 5 mOsm/kg, p = 0.028 and a larger plasma volume expansion (11 ± 10 vs. 1 ± 15%, p = 0.041 compared to participants not developing AMS. Net water balance (fluid intake--fluid loss and the amount of fluid loss were strong predictors whether getting sick or not (Nagelkerkes r(2 = 0.532. The LLS score was related to net water balance (r = 0.358, p = 0.018, changes in plasma osmolality (r = -0.325, p = 0.033 and sodium concentration (r = -0.305, p = 0.047. Changes in the impedance vector length were related to weight changes (r = -0.550, p<0.001, fluid intake (r = -0.533, p<0.001 and net water balance (r = -0.590, p<0.001. CONCLUSIONS: Participants developing AMS within 12 hours showed a positive net water balance due to low fluid loss. Thus measures to avoid excess fluid retention are likely to reduce AMS symptoms.

  18. Whole body bone scintigraphy in osseous hydatosis: a case report

    Directory of Open Access Journals (Sweden)

    Ebrahimi Abdolali

    2007-09-01

    Full Text Available Abstract Hydatid disease is common in many parts of the world, and causes considerable health and economic loss. This disease may develop in almost any part of the body. Bone involvement is often asymptomatic, and its diagnosis is primarily based on radiographic findings. A whole body bone scan is able to show the extent and distribution of lesions. We describe an unusual case of multifocal skeletal hydatosis and also explain the clinical and diagnostic points. We hope to stimulate a high index of suspicion among clinicians to facilitate early diagnosis and to consider this disease as a differential diagnosis in cases of multiple abnormal activity in bone scintigraphy especially among people in endemic areas.

  19. Hilar activity on the F-18 FDG whole-body PET studies

    International Nuclear Information System (INIS)

    Fujii, Hirofumi; Kitamura, Masayuki; Kubo, Atsushi; Yasuda, Seiei; Ide, Michiru; Takahashi, Wakoh; Shohtsu, Akira

    1999-01-01

    We evaluated the clinical characteristics of hilar activity that would be false positive findings for cancer screening on whole-body FDG PET. The cases with increased hilar activity were selected from 1,126 cases who received whole-body FDG PET between September 1996 and August 1997, and their age, sex, complication of inflammatory process in lungs, numbers of visualized mediastinal lymph nodes, frequency of smoking, blood sugar level and concentration of HbA1c were studied. FDG accumulation in the hilar regions was found in 63 cases (5.6%). The cases with increased hilar activity were older, a higher incidence of complication of pulmonary inflammation, a larger number of visualized mediastinal lymph nodes and were more frequent smokers than the control cases with normal FDG distribution. Their male-to-female ratio, blood sugar level and concentration of HbA1c were not significantly different from those of the control cases. These results suggested that an inflammatory process around the hilar region might induce this confusing FDG accumulation. (author)

  20. Whole-body counting installation for assessment of internal contamination in workers

    International Nuclear Information System (INIS)

    Oliveira, C.A.N.; Cunha, P.G.; Lipsztein, J.L.; Bertelli, L.N.; Fonseca, A.M.G.; Ramalho, A.T.

    1985-01-01

    A whole-body counting installation for assessment of internal contamination in workers has recently been added to the Bioassay Division of the Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (IRD/CNEN). For the last two years the laboratory has been monitoring personnel involved in uranium mining and milling activities, monazite industry workers and nuclear medicine staff dealing with iodine-131 and technetium-99. Uptakes of radionuclides by the different organs and also dose equivalents are evaluated through the use of mathematical models. The IRD whole-body counter unit was specially designed to detect a variety of internally deposited radionuclides which emit photons in the energy range of 15 keV to 3 MeV. It consists of a monitoring room (2.5x2.5x2.5 m internal dimension), with 0.15 m thick steel walls, internally lined with 0.3 cm lead, 0.15 cm cadmium and 0.05 cm thick copper sheets. The facility is equipped with three different size NaI(T1) detectors and three 12.7 cm diameter phoswich detectors. (author)

  1. The influence of whole body 60Co-irradiation on distribution of 67Ga in tumor-bearing mice

    International Nuclear Information System (INIS)

    Wakao, Hiromi; Shimura, Akira; Higashi, Tomomitsu

    1981-01-01

    Since the initial findings that 67 Ga has a preferential affinity for soft tissue tumors, in humans numerous suggestions have been advanced for the basic mechanism involved. The effects produced by whole-body X-irradiation on the excretion and tissue distribution of 67 Ga have been reported by Swartzendruber and others. Bradley and coworkers have shown that these irradiation effects were associated with an increase in serum iron. The present investigation was undertaken in order to study the relationships between the change in the serum iron concentration and 67 Ga accumulation in the tumor and soft tissues in mice bearing Ehrlich's ascites tumor. The following results were obtained. (1) The serum iron concentration was significantly decreased between 3 and 6 hours after 10 Gy (1,000 rad) dose of whole-body 60 Co-irradiation. Subsequently, the serum iron levels were slowly elevated. (2) The uptake of 67 Ga in the tumor and soft tissues was increased if the serum iron concentration was decreased by whole-body 60 Co-irradiation during the early phase. On the contrary, if the serum iron concentration was high, the uptake of 67 Ga in the tumor was decreased. (3) The excretion of 67 Ga from the body was delayed if the serum iron concentration was decreased by whole-body 60 Co-irradiation. However, if the serum iron concentration was high, the excretion of 67 Ga from the body significantly increased. (author)

  2. Mechanisms of taurine hyperexcretion after whole-body irradiation of rats

    International Nuclear Information System (INIS)

    Beskrovnaya, L.A.; Lapteva, T.A.; Dokshina, G.A.; Baranova, M.I.

    1976-01-01

    Mechanisms of postirradiation hyperexcretion of taurine with urine have been investigated. In the course of three days after a whole-body exposure of rats (700 rads), the excretion of taurine increases. The experiments in vitro have demonstrated that taurine synthesis decreases in the thymus and liver of irradiated animals. The experiments conducted have shown that the postirradiation hyperexcretion of taurine is partly due to its release from the lymohoid tissue (thymus)

  3. Evaluation of /sup 111/In leukocyte whole body scanning

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-11-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with /sup 111/In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes.

  4. Comparison of 99m-Tc-MDP and 99m-Tc-MIBI whole body scans for diagnosis of widespread skeletal metastases

    International Nuclear Information System (INIS)

    Ansari, M.; Hoshiar, A.; Mortazavi, S.H.

    2002-01-01

    Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient's life, both quantitatively and qualitatively and prevent exacerbation of the disease and disabling complications. In this study 22 patients with established diagnosis of malignant disease and clinical manifestations of skeletal metastasis were evaluated both with 99 m-Tc-MIBI and 99 m-Tc-MDP whole body scans, in two separate phases. Patient's diagnosis were as following: small round cell tumor, breast carcinoma. Nasopharynx carcinoma and multiple myeloma. In the first phase of the study a whole body bone scan was performed by IV injection of 740MBq 99 m-Tc-MDP. After a period of 1 week a whole body scan carried out by 99 m-Tc-MDP for all the patients. No treatment such as radiation therapy ar chemotherapy was done in this 1 week interval. The number and intensity of the scan findings were compared visually, according to the three- phase staging, subsequently. whole body survey with 99 m-Tc-MDP in 14 out 22 patient were positive demonstrating only 44.4% of body lesions established on whole body bone scan with 99 m-Tc-MDP. The mean value of intensity of radiotracer uptake was around 1.5+ (mild to moderate ). on the other hand in 7 patients with positive 99 m-Tc-MDP scan some hidden soft tissue lesions ( mostly lymph nodes) were detected with intensity of 2+. So this study shows that whole body bone scan is preferable for detection of widespread metastasis comparing with 99 m-Tc-MDP whole body scan. the significance of 99 m-Tc-MDP scan is mainly limited to some equivocal of soft tissue lesions

  5. Whole-body 35-GHz security scanner

    Science.gov (United States)

    Appleby, Roger; Anderton, Rupert N.; Price, Sean; Sinclair, Gordon N.; Coward, Peter R.

    2004-08-01

    A 35GHz imager designed for Security Scanning has been previously demonstrated. That imager was based on a folded conical scan technology and was constructed from low cost materials such as expanded polystyrene and printed circuit board. In conjunction with an illumination chamber it was used to collect indoor imagery of people with weapons and contraband hidden under their clothing. That imager had a spot size of 20mm and covered a field of view of 20 x 10 degrees that partially covered the body of an adult from knees to shoulders. A new variant of this imager has been designed and constructed. It has a field of view of 36 x 18 degrees and is capable of covering the whole body of an adult. This was achieved by increasing the number of direct detection receivers from the 32 used in the previous design to 58, and by implementing an improved optical design. The optics consist of a front grid, a polarisation device which converts linear to circular polarisation and a rotating scanner. This new design uses high-density expanded polystyrene as a correcting element on the back of the front grid. This gives an added degree of freedom that allows the optical design to be diffraction limited over a very wide field of view. Obscuration by the receivers and associated components is minimised by integrating the post detection electronics at the receiver array.

  6. VIP-Man: An image-based whole-body adult male model constructed from color photographs of the visible human project for multi-particle Monte Carlo calculations

    International Nuclear Information System (INIS)

    Xu, X.G.; Chao, T.C.; Bozkurt, A.

    2000-01-01

    Human anatomical models have been indispensable to radiation protection dosimetry using Monte Carlo calculations. Existing MIRD-based mathematical models are easy to compute and standardize, but they are simplified and crude compared to human anatomy. This article describes the development of an image-based whole-body model, called VIP-Man, using transversal color photographic images obtained from the National Library of Medicine's Visible Human Project for Monte Carlo organ dose calculations involving photons, electron, neutrons, and protons. As the first of a series of papers on dose calculations based on VIP-Man, this article provides detailed information about how to construct an image-based model, as well as how to adopt it into well-tested Monte Carlo codes, EGS4, MCNP4B, and MCNPX

  7. Influence of 2,3-dimercaptosuccinic acid on gastrointestinal lead absorption and whole-body lead retention

    International Nuclear Information System (INIS)

    Kapoor, S.C.; Wielopolski, L.; Graziano, J.H.; LoIacono, N.J.

    1989-01-01

    2,3-Dimercaptosuccinic acid (DMSA) is a new orally active heavy metal chelator for the treatment of childhood Pb intoxication on an outpatient basis. The influence of DMSA, as well as other chelating agents, on gastrointestinal 203Pb absorption and whole-body 203 Pb retention was examined. Groups of Sprague-Dawley rats (230-260 g) were gavaged with a solution containing approximately 25 mg/kg Pb [as Pb(NO 3 )2] plus 15 microCi 203 Pb. Some groups were then immediately given 0.11 mmol/kg of either DMSA, CaNa2EDTA, D-penicillamine, or BAL by oral gavage, while other groups received the same drugs by ip injection. Control groups received solutions of the drug vehicles po or ip. Whole-body Pb retention and gastrointestinal Pb absorption (whole body retention + urinary Pb excretion) were significantly decreased in rats that received DMSA po. This finding implies that the use of DMSA to treat childhood lead intoxication on an outpatient basis is not associated with a risk for increased Pb absorption

  8. Whole-body muscle MRI in 20 patients suffering from late onset Pompe disease: Involvement patterns.

    Science.gov (United States)

    Carlier, Robert-Yves; Laforet, Pascal; Wary, Claire; Mompoint, Dominique; Laloui, Kenza; Pellegrini, Nadine; Annane, Djillali; Carlier, Pierre G; Orlikowski, David

    2011-11-01

    To describe muscle involvement on whole-body MRI scans in adult patients at different stages of late-onset Pompe disease. Twenty patients aged 37 to 75 were examined. Five were bedridden and required ventilatory support. Axial and coronal T1 turbo-spin-echo sequences were performed on 1.5T or 3T systems. MRI was scored for 47 muscles using Mercuri's classification. Whole-body scans were obtained with a mean in-room time of 29 min. Muscle changes consisted of internal bright signals of fatty replacement without severe retraction of the muscles' corpus. Findings were consistent with previous descriptions of spine extensors and pelvic girdle, but also provided new information on recurrent muscle changes particularly in the tongue and subscapularis muscle. Moreover thigh involvement was more heterogeneous than previously described, in terms of distribution across muscles as well as with respect to the overall clinical presentation. Whole-body MRI provides a very evocative description of muscle involvement in Pompe disease in adults. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET

    NARCIS (Netherlands)

    Karakatsanis, Nicolas A.; Zhou, Yun; Lodge, Martin A.; Casey, Michael E.; Wahl, Richard L.; Zaidi, Habib; Rahmim, Arman

    2015-01-01

    We recently developed a dynamic multi-bed PET data acquisition framework to translate the quantitative benefits of Patlak voxel-wise analysis to the domain of routine clinical whole-body (WB) imaging. The standard Patlak (sPatlak) linear graphical analysis assumes irreversible PET tracer uptake,

  10. Prolonged whole-body cold water immersion: fluid and ion shifts.

    Science.gov (United States)

    Deuster, P A; Smith, D J; Smoak, B L; Montgomery, L C; Singh, A; Doubt, T J

    1989-01-01

    To characterize fluid and ion shifts during prolonged whole-body immersion, 16 divers wearing dry suits completed four whole-body immersions in 5 degrees C water during each of two 5-day air saturation dives at 6.1 msw. One immersion was conducted at 1000 (AM) and one at 2200 (PM) so that diurnal variations could be evaluated. Fifty-four hours separated the immersions, which lasted up to 6 h; 9 days separated each air saturation dive. Blood was collected before and after immersion; urine was collected for 12 h before, during, and after immersion for a total of 24 h. Plasma volume decreased significantly and to the same extent (approximately 17%) during both AM and PM immersions. Urine flow increased by 236.1 +/- 38.7 and 296.3 +/- 52.0%, urinary excretion of Na increased by 290.4 +/- 89.0 and 329.5 +/- 77.0%, K by 245.0 +/- 73.4 and 215.5 +/- 44.6%, Ca by 211.0 +/- 31.4 and 241.1 +/- 50.4%, Mg by 201.4 +/- 45.9 and 165.3 +/- 287%, and Zn by 427.8 +/- 93.7 and 301.9 +/- 75.4% during AM and PM immersions, respectively, compared with preimmersion. Urine flow and K excretion were significantly higher during the AM than PM. In summary, when subjects are immersed in cold water for prolonged periods, combined with a slow rate of body cooling afforded by thermal protection and enforced intermittent exercise, there is diuresis, decreased plasma volume, and increased excretions of Na, K, Ca, Mg, and Zn.

  11. Acid base balance in the rabbit following whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Bassant, M.-H.; Touchard, Francoise; Court, Louis

    1981-01-01

    2 hrs. after whole-body gamma irradiation (doses of 1.5 and 4.5 Gy) a metabolic acidosis developed in curarised Rabbits placed under artificial respiration in order to eliminate radiation-induced respiratory effect. The metabolic acidosis was evaluated by measurement of the negative base excess. The results were compared to others obtained under different experimental procedures [fr

  12. Acid base balance in the rabbit following whole-body gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bassant, M.H.; Touchard, F.; Court, L. (CEA Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Recherches sur la Fusion Controlee)

    1981-07-06

    2 hrs. after whole-body gamma irradiation (doses of 1.5 and 4.5 Gy) a metabolic acidosis developed in curarised rabbits placed under artificial respiration in order to eliminate radiation-induced respiratory effect. The metabolic acidosis was evaluated by measurement of the negative base excess. The results were compared to others obtained under different experimental procedures.

  13. Whole-body γ-irradiation effects on catecholamine concentration in animal tissues

    International Nuclear Information System (INIS)

    Makashev, Zh.K.; Uteshev, T.A.; Abylaev, Zh. A.; Zhurnist, A.G.

    2003-01-01

    On the whole-body gamma-radiation activity in the exchanges of catecholamines (adrenalin and non-adrenalin) and their predecessors (dopamine and DOPA) in the rats tissue organism, indicate the infringement of irradiated animals in different links of biological synthesis the bio-gen amines in different phases of the radiation: DOPA→dopamine, dopamine→adrenalin, adrenalin→non-adrenalin. (author)

  14. Whole- and partial-body cryostimulation/cryotherapy: Current technologies and practical applications.

    Science.gov (United States)

    Bouzigon, Romain; Grappe, Frederic; Ravier, Gilles; Dugue, Benoit

    2016-10-01

    Cold therapy is commonly used as a method to relieve pain and inflammation. This review focuses primarily on two methods of cold therapy that have received recent attention: whole-body cryotherapy and partial-body cryotherapy. These methods are used to induce physiological and psychological benefits in humans in the context of medicine, health and sports. The subjects experiencing cryotherapy are dressed in minimal clothing and are exposed to very cold air (at -110°C or less) for 1-4min. Despite the increasing scientific interest in these methods, there is a lack of information about the technologies used. Moreover, there is no existing reference concerning exposure protocols and the relationship between temperature, duration, number of repetitions and the treatments' desired effects. The aim of this review is to compare whole- and partial-body cryotherapy effects (especially on skin temperature) and to classify the protocols for exposure according to the desired effects. This review emphasises 1) the lack of information concerning the actual temperatures inside the cabin or chamber during exposure and 2) the heterogeneity among the exposure protocols that have been reported in the scientific literature. This review will be valuable and relevant to health professionals endeavouring to optimize the cold treatments offered to patients and producers of cryotherapy apparatus striving to create more efficient devices that meet market requirements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. [Psychological effects of long-term occupational whole body vibration].

    Science.gov (United States)

    Schneider, H; Wall, H

    1989-04-01

    Long-term effects of occupational whole-body vibration (WBV) on psychic performance and on well-being have hardly been described in the literature to date. However, they cannot be excluded, since numerous findings exist on impairments of performance and of well-being in experimentally conditioned short-term effects. Within the framework of comprehensive clearing-up diagnostics in occupational health, 20 male subjects with many years of occupational exposure to WBV were investigated according to a standardized psychodiagnostic programme of methods. The highest rate of pathological findings resulted in the areas of visual perception speed and subtle motory speed of movements. Furthermore, the results are evidence for an interrelation between the duration of exposure and disturbances in the areas of attention, as well as of sensomotory selection responses. As a whole, the results essentially affect the same psychological variables as the results of the short-term studies, but are to be evaluated with reservations on methodological grounds.

  16. Computational Fluid Dynamics of Whole-Body Aircraft

    Science.gov (United States)

    Agarwal, Ramesh

    1999-01-01

    The current state of the art in computational aerodynamics for whole-body aircraft flowfield simulations is described. Recent advances in geometry modeling, surface and volume grid generation, and flow simulation algorithms have led to accurate flowfield predictions for increasingly complex and realistic configurations. As a result, computational aerodynamics has emerged as a crucial enabling technology for the design and development of flight vehicles. Examples illustrating the current capability for the prediction of transport and fighter aircraft flowfields are presented. Unfortunately, accurate modeling of turbulence remains a major difficulty in the analysis of viscosity-dominated flows. In the future, inverse design methods, multidisciplinary design optimization methods, artificial intelligence technology, and massively parallel computer technology will be incorporated into computational aerodynamics, opening up greater opportunities for improved product design at substantially reduced costs.

  17. Safety aspects of whole-body cryochamber and cryosauna operation

    Science.gov (United States)

    Agnieszka, Piotrowska

    2017-12-01

    Interest in low temperature treatment is constantly increasing. Whole-body cryotherapy (WBC) devices are becoming available not only in medical centers but also in local gyms and spa centers. A new group of users are professional sport clubs where 3-minutes session of whole-body cryotherapy is post-training procedure to improve and speed up the recovery process. There are four different types of WBC devices available on the market and offered to commercial (non-medical) users. The American and European market is dominated by two of them: classic cryochambers and cryosaunas. Both constructions are supplied with liquid nitrogen. Low temperature inside classic cryochamber is produced by evaporating of liquid nitrogen in two or more heat exchangers. There is never a direct contact between user and cryogenic medium in any of system operation mode (closed supply system). Cryosauna is cooled down by filling with cold vapor of liquid nitrogen. Supply system is considered open because it allows for direct contact between user and cryogenic medium. Open supply system of cryosauna is primary and most questionable issue of its operational safety, particularly after tragic accident in October 2015. This paper presents the comparative analysis of classic cryochamber and cryosauna from safety point of view. Both devices have been analyzes and tested on existing systems in operation. Paper gives detailed analysis of constructions, supply systems and working parameters. Special attention has been focused to problem of oxygen deficiency hazard. Different failure or accident scenarios have been analyzed and discussed.

  18. Whole-body vibration does not influence knee joint neuromuscular function or proprioception.

    Science.gov (United States)

    Hannah, R; Minshull, C; Folland, J P

    2013-02-01

    This study examined the acute effects of whole-body vibration (WBV) on knee joint position sense and indices of neuromuscular function, specifically strength, electromechanical delay and the rate of force development. Electromyography and electrically evoked contractions were used to investigate neural and contractile responses to WBV. Fourteen healthy males completed two treatment conditions on separate occasions: (1) 5 × 1 min of unilateral isometric squat exercise on a synchronous vibrating platform [30 Hz, 4 mm peak-to-peak amplitude] (WBV) and (2) a control condition (CON) of the same exercise without WBV. Knee joint position sense (joint angle replication task) and quadriceps neuromuscular function were assessed pre-, immediately-post and 1 h post-exercise. During maximum voluntary knee extensions, the peak force (PF(V)), electromechanical delay (EMD(V)), rate of force development (RFD(V)) and EMG of the quadriceps were measured. Twitch contractions of the knee extensors were electrically evoked to assess EMD(E) and RFD(E). The results showed no influence of WBV on knee joint position, EMD(V), PF(V) and RFD(V) during the initial 50, 100 or 150 ms of contraction. Similarly, electrically evoked neuromuscular function and neural activation remained unchanged following the vibration exercise. A single session of unilateral WBV did not influence any indices of thigh muscle neuromuscular performance or knee joint proprioception. © 2011 John Wiley & Sons A/S.

  19. Effect of abomasal glucose infusion on splanchnic and whole-body glucose metabolism in periparturient dairy cows

    DEFF Research Database (Denmark)

    Larsen, Mogens; Kristensen, Niels Bastian

    2009-01-01

    Six periparturient Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the hepatic portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic and whole-body glucose metabolism.......Six periparturient Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the hepatic portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic and whole-body glucose metabolism....

  20. Electron Cloud Simulations of a Proton Storage Ring Using Cold Proton Bunches

    International Nuclear Information System (INIS)

    Sato, Y.; Holmes, Jeffrey A.; Lee, S.Y.; Macek, R.

    2008-01-01

    Using the ORBIT code we study the sensitivity of electron cloud properties with respect to different proton beam profiles, the secondary electron yield (SEY) parameter, and the proton loss rate. Our model uses a cold proton bunch to generate primary electrons and electromagnetic field for electron cloud dynamics. We study the dependence of the prompt and swept electron signals vs the bunch charge and the recovery of electron clouds after sweeping on the beam loss rate and the SEY. The simulation results are compared with the experimental data measured at the proton storage ring at the Los Alamos National Laboratory. Our simulations indicate that the fractional proton loss rate in the field-free straight section may be an exponential function of proton beam charge and may also be lower than the averaged fractional proton loss rate over the whole ring.

  1. Targeted microbubbles for imaging tumor angiogenesis: assessment of whole-body biodistribution with dynamic micro-PET in mice

    DEFF Research Database (Denmark)

    Willmann, Jürgen K; Cheng, Zhen; Davis, Corrine

    2008-01-01

    To evaluate in vivo whole-body biodistribution of microbubbles (MBs) targeted to tumor angiogenesis-related vascular endothelial growth factor (VEGF) receptor 2 (VEGFR2) by using dynamic micro-positron emission tomography (PET) in living mice.......To evaluate in vivo whole-body biodistribution of microbubbles (MBs) targeted to tumor angiogenesis-related vascular endothelial growth factor (VEGF) receptor 2 (VEGFR2) by using dynamic micro-positron emission tomography (PET) in living mice....

  2. Vibration energy absorption in the whole-body system of a tractor operator.

    Science.gov (United States)

    Szczepaniak, Jan; Tanaś, Wojciech; Kromulski, Jacek

    2014-01-01

    Many people are exposed to whole-body vibration (WBV) in their occupational lives, especially drivers of vehicles such as tractor and trucks. The main categories of effects from WBV are perception degraded comfort interference with activities-impaired health and occurrence of motion sickness. Absorbed power is defined as the power dissipated in a mechanical system as a result of an applied force. The vibration-induced injuries or disorders in a substructure of the human system are primarily associated with the vibration power absorption distributed in that substructure. The vibration power absorbed by the exposed body is a measure that combines both the vibration hazard and the biodynamic response of the body. The article presents measurement method for determining vibration power dissipated in the human whole body system called Vibration Energy Absorption (VEA). The vibration power is calculated from the real part of the force-velocity cross-spectrum. The absorbed power in the frequency domain can be obtained from the cross-spectrum of the force and velocity. In the context of the vibration energy transferred to a seated human body, the real component reflects the energy dissipated in the biological structure per unit of time, whereas the imaginary component reflects the energy stored/released by the system. The seated human is modeled as a series/parallel 4-DOF dynamic models. After introduction of the excitation, the response in particular segments of the model can be analyzed. As an example, the vibration power dissipated in an operator has been determined as a function of the agricultural combination operating speed 1.39 - 4.16 ms(-1).

  3. Quantitative analysis of skin reaction by reflectance spectrophotometer. Acute reaction following proton therapy

    International Nuclear Information System (INIS)

    Kawashima, Mitsuhiko; Okumura, Toshiyuki; Tatsuzaki, Hideo; Tsuji, Hiroshi; Tsujii, Hirohiko.

    1994-01-01

    Acute reactions induced by proton irradiation were measured using a reflectance spectrophotometer, which is commonly used in the printing and textile industries. In this method, the skin color was expressed by three parameters, lightness (L * ), chroma (C * ) and hue (h). At first, in order to evaluate the accuracy of this spectrophotometer, the skin color of a normal volunteer was measured 100 times. The values of the three parameters for normal skin were as follows (mean values and standard deviation), L * : 68.64±0.29, C * : 19.08±0.13, h: 69.41±0.76. The standard deviations with regard to L * and h, were considered to be sufficiently small when compared with the changes of these parameters (prefix: Δ) in the irradiated sites (ΔL * * and h values significantly decreased with time, and the L * values were highly correlated with elapsed treatment days. The h values had a relatively low linear correlation compared with L * . The C * values had no trends as the treatment period was extended. Among these parameters, the L * values were the most valuable for assessment of proton-induced skin reactions, and it was suggested that the L * values measured with this spectrophotometer were a useful index for showing biological effects induced by proton irradiation. Further experiments are needed to apply this method to quantify the biological effects induced by other forms of ionizing radiation. (author)

  4. Proton activation analysis at the Harvard Cyclotron Laboratory

    International Nuclear Information System (INIS)

    Sisterson, J.M.; Koehler, A.M.

    1984-01-01

    High-energy proton activation analysis (PAA), a simple non-destructive technique, has been developed for use as an adjunct to neutron activation analysis. Potential advantages of protons include the ability to achieve very precise localization of the activation volume over a pre-determined depth in the target. To demonstrate the versatility of PAA, results are reported on the measurement of the whole body calcium content in animals and on the determination of the Ca/P molar ratio in small quantities (<50 mg) of chemical and biological samples. The animal experiments demonstrate the ability to achieve a uniform irradiation over a large volume and utilizes large NaI crystals with a special chamber for uniform combined detection efficiency, where the Ca/P molar ratio determination requires a Ge/Li detector and analysis of the resulting gamma ray spectrum. The feasibility is being assessed of using proton beam activation of the eye to measure blood flow in the rabbit choroid, based on earlier work where it was used to measure blood in mouse skeletal tissue. 6 references, 7 figures, 4 tables

  5. Beneficial effects of the whole-body cryotherapy on sport haemolysis

    OpenAIRE

    Banfi, Giuseppe; Melegati, Gianluca; Barassi, Alessandra; Melzi d'Eril, Gianvico

    2009-01-01

    Background. Sport's anemia is a common risk for athletes. The principal source of an accelerated turnover of the erythrocytes in sportsmen is the intravascular hemolysis. This phenomenon is induced by mechanical breakage for impact of feet and muscular contractions, but also by osmotic changes causing membrane fragility, typically evident after exercise, when free radicals are increased. Whole-body cryotherapy (WBC) covers a wide range of therapeutic applications and consists of briefly expos...

  6. Assessment of Whole Body and Local Muscle Fatigue Using Electromyography and a Perceived Exertion Scale for Squat Lifting

    Directory of Open Access Journals (Sweden)

    Imran Ahmad

    2018-04-01

    Full Text Available This research study aims at addressing the paradigm of whole body fatigue and local muscle fatigue detection for squat lifting. For this purpose, a comparison was made between perceived exertion with the heart rate and normalized mean power frequency (NMPF of eight major muscles. The sample consisted of 25 healthy males (age: 30 ± 2.2 years. Borg’s CR-10 scale was used for perceived exertion for two segments of the body (lower and upper and the whole body. The lower extremity of the body was observed to be dominant compared to the upper and whole body in perceived response. First mode of principal component analysis (PCA was obtained through the covariance matrix for the eight muscles for 25 subjects for NMPF of eight muscles. The diagonal entries in the covariance matrix were observed for each muscle. The muscle with the highest absolute magnitude was observed across all the 25 subjects. The medial deltoid and the rectus femoris muscles were observed to have the highest frequency for each PCA across 25 subjects. The rectus femoris, having the highest counts in all subjects, validated that the lower extremity dominates the sense of whole body fatigue during squat lifting. The findings revealed that it is significant to take into account the relation between perceived and measured effort that can help prevent musculoskeletal disorders in repetitive occupational tasks.

  7. Assessment of Whole Body and Local Muscle Fatigue Using Electromyography and a Perceived Exertion Scale for Squat Lifting.

    Science.gov (United States)

    Ahmad, Imran; Kim, Jung-Yong

    2018-04-18

    This research study aims at addressing the paradigm of whole body fatigue and local muscle fatigue detection for squat lifting. For this purpose, a comparison was made between perceived exertion with the heart rate and normalized mean power frequency (NMPF) of eight major muscles. The sample consisted of 25 healthy males (age: 30 ± 2.2 years). Borg’s CR-10 scale was used for perceived exertion for two segments of the body (lower and upper) and the whole body. The lower extremity of the body was observed to be dominant compared to the upper and whole body in perceived response. First mode of principal component analysis (PCA) was obtained through the covariance matrix for the eight muscles for 25 subjects for NMPF of eight muscles. The diagonal entries in the covariance matrix were observed for each muscle. The muscle with the highest absolute magnitude was observed across all the 25 subjects. The medial deltoid and the rectus femoris muscles were observed to have the highest frequency for each PCA across 25 subjects. The rectus femoris, having the highest counts in all subjects, validated that the lower extremity dominates the sense of whole body fatigue during squat lifting. The findings revealed that it is significant to take into account the relation between perceived and measured effort that can help prevent musculoskeletal disorders in repetitive occupational tasks.

  8. High-intensity interval training using whole-body exercises: training recommendations and methodological overview.

    Science.gov (United States)

    Machado, Alexandre F; Baker, Julien S; Figueira Junior, Aylton J; Bocalini, Danilo S

    2017-05-04

    HIIT whole body (HWB)-based exercise is a new calisthenics exercise programme approach that can be considered an effective and safe method to improve physical fitness and body composition. HWB is a method that can be applied to different populations and ages. The purpose of this study was to describe possible methodologies for performing physical training based on whole-body exercise in healthy subjects. The HWB sessions consist of a repeated stimulus based on high-intensity exercise that also include monitoring time to effort, time to recuperation and session time. The exercise intensity is related to the maximal number of movements possible in a given time; therefore, the exercise sessions can be characterized as maximal. The intensity can be recorded using ratings of perceived exertion. Weekly training frequency and exercise selection should be structured according to individual subject functional fitness. Using this simple method, there is potential for greater adherence to physical activity which can promote health benefits to all members of society. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  9. Body composition in long-term survivors of acute lymphoblastic leukemia diagnosed in childhood and adolescence: A focus on sarcopenic obesity.

    Science.gov (United States)

    Marriott, Christopher J C; Beaumont, Lesley F; Farncombe, Troy H; Cranston, Amy N; Athale, Uma H; Yakemchuk, Valerie N; Webber, Colin E; Barr, Ronald D

    2018-03-15

    The late effects of treatment for acute lymphoblastic leukemia (ALL) include disordered body composition, especially obesity. Less attention has been focused on the loss of skeletal muscle mass (SMM) and the combined morbidity of sarcopenic obesity. A cross-sectional study of body composition was undertaken via dual-energy x-ray absorptiometry in 75 long-term survivors of ALL (more than 10 years after the diagnosis). Measures were obtained of the fat mass (FM), fat-free mass (equivalent to the lean body mass [LBM]), and whole-body bone mineral content. Health-related quality of life (HRQL) was measured with the Health Utilities Index. The sum of the FM, LBM, and whole-body bone mineral content matched the total body weight measured directly (r = 0.998). The appendicular lean mass (ALM) was derived from the LBM in all 4 limbs and accounted for approximately 75% of the SMM. According to the fat mass index (FMI; ie, FM/height 2 ), 12% of females and 18% of males were frankly obese by World Health Organization criteria. The median FMI z score was + 0.40, whereas the median z score for the appendicular lean mass index (ALMI; ie, ALM/height 2 ) was -0.40. Sarcopenic obesity, defined as a positive FMI z score with a negative ALMI z score, was present in 32 subjects (43%). There were statistically significant and clinically important differences in overall HRQL between subjects with and without sarcopenic obesity. Sarcopenic obesity is prevalent in long-term survivors of ALL, and this places them in double jeopardy from excess body fat and inadequate SMM (eg, a combination of metabolic and frailty syndromes). It is associated with an adverse impact on overall HRQL. Cancer 2018;124:1225-31. © 2017 American Cancer Society. © 2017 American Cancer Society.

  10. Whole-body distribution and dosimetry of O-(2-[{sup 18}F]fluoroethyl)-l-tyrosine

    Energy Technology Data Exchange (ETDEWEB)

    Pauleit, Dirk [Clinic of Nuclear Medicine, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany); Clinic of Nuclear Medicine, Research Center Juelich, P.O. Box 1913, 52425, Juelich (Germany); Floeth, Frank [Department of Neurosurgery, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany); Herzog, Hans; Tellmann, Lutz; Langen, Karl-J. [Institute of Medicine, Research Center Juelich, Juelich (Germany); Hamacher, Kurt; Coenen, Heinz H. [Institute of Nuclear Chemistry, Research Center Juelich, Juelich (Germany); Mueller, Hans-W. [Clinic of Nuclear Medicine, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany)

    2003-04-01

    The whole-body distribution of O-(2-[{sup 18}F]fluoroethyl)-l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV {<=}1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 {mu}Sv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET. (orig.)

  11. The role of embodied simulation in mental transformation of whole-body images: evidence from Parkinson's disease.

    Science.gov (United States)

    Conson, Massimiliano; Trojano, Luigi; Vitale, Carmine; Mazzarella, Elisabetta; Allocca, Roberto; Barone, Paolo; Grossi, Dario; Santangelo, Gabriella

    2014-02-01

    It has been repeatedly demonstrated that mentally performing an action and mentally transforming body-parts entail simulation of one's own body movements, consistent with predictions of embodied cognition theories. However, the involvement of embodied simulation in mental transformation of whole-body images is still disputed. Here, we assessed own body transformation in Parkinson's disease (PD) patients with symptoms most affecting the left or the right body side. PD patients were required to perform left-right judgments on front-facing or back-facing human figures, and a letter rotation task. Results demonstrated that PD patients were selectively impaired in judging the side of back-facing human figures corresponding to their own most affected side, but performed as well as healthy subjects on mental transformation of front-facing bodies and on letter rotation. These findings demonstrate a parallel impairment between motor and mental simulation mechanisms in PD patients, thus highlighting the specific contribution of embodied cognition to mental transformation of whole-body images. Copyright © 2014. Published by Elsevier B.V.

  12. Pathogenesis and symptomatics of the acute radiation syndrome

    International Nuclear Information System (INIS)

    Fliedner, T.M.; Haen, M.; Carbonell, F.

    1980-01-01

    The pathogenesis and symptomatics of the acute radiation syndrome are discussed. Diagnosis and therapy would be impossible without detailed knowledge in these fields. The concept of acute radiation syndrome is explained, and a pathophysiological analysis of the various forms of radiation syndrome - haematological, intestinal and affecting the central nervous system is attempted. The developments in the diagnosis and therapy of acute radiation syndrome since its first description - 35 years ago - are reviewed. Today, whole-body doses of 100 rd and more can be treated by radiotherapy. (orig./MG) [de

  13. Optimization of whole-body PET imaging protocol for the detection of 18F-FDG overlappings in oncology

    International Nuclear Information System (INIS)

    Lartizien, C.

    2001-01-01

    Positron emission tomography (PET) is a nuclear imaging modality that allows studying in vivo cellular metabolic and biochemical processes. During the 90's, there has been a growing interest in the applications of PET in oncology related to the use of a glucose analog (FDG) labeled with the positron emitter 18 F. This tracer of the glucose metabolism is trapped in the cancer cells characterized by a deregulated glycolytic activity. This allows detecting tumors and metastases. The interest of PET in oncology has lead to develop imaging systems and protocols to perform whole-body acquisitions of the patient. Whole-body PET imaging has been limited in practice by the high level of statistical noise that affects the detection of small lesions due to limited radioactive dose injected to the patient and short acquisition time. In this context, our work focused on the optimization of detection performances in whole-body 18 F-FDG PET images. We have first developed an original method to evaluate detectability based on the psychophysical approach of the ROC methodology and adapted to the specificity of whole-body PET images. This method was used to evaluate detection performances of different reconstruction algorithms used for whole-body imaging. We have also studied the influence of the acquisition mode, namely the 2D and the 3D modes. To that purpose, we have used the NEC index to select relevant statistical acquisition conditions in both acquisition modes as a function of the injected dose to the patient. Then, we have compared the detection performances of these different acquisition conditions based on our psychophysical evaluation technique. (author) [fr

  14. Is whole body bone mineral density measured by the dual energy X-ray absorptiometry applied to evaluate risk of osteoporosis among Japanese adult females?

    International Nuclear Information System (INIS)

    Sakai, Yumiko; Koike, George; Numata, Makoto; Taneda, Kiyoshi; Jingu, Sumie

    2010-01-01

    The purpose of this study is to measure whole body fat accurately, the dual energy X-ray absorptiometry (DXA) is widely utilized. Simultaneously, bone mineral density (BMD) of the whole body can also be measured. BMD is one of important information to diagnose osteoporosis. However, it is not established to use whole body BMD for this diagnosis. It is recommended that lumbar and/or hip BMD should be used for diagnosing osteoporosis by the guideline for prevention and treatment of osteoporosis. Although it is possible to measure whole body BMD and lumbar and/or hip BMD separately at the same visit, it is inevitable to expose patients to more X-ray. Therefore, an aim of this study is to elucidate the relationship between whole body BMD and lumbar BMD to find the cut off point of whole body BMD for screening of osteoporosis. Two hundred and thirty six Japanese adult females were ascertained to this study. Whole body BMD and lumbar BMD of each subject were measured with the use of Delphi W (Hologic, USA). One hundred and sixty five subjects were judged as possible osteoporosis (less than 80% of young adult mean (YAM) of lumbar BMD and/or definite fracture of lumbar vertebras). The cut off point of whole body BMD for screening possible osteoporosis was estimated by receiver operated characteristic (ROC) analysis. The cut off point of whole body BMD was 84% of YAM, equivalent to 80% of YAM of lumbar BMD, with the following sensitivity and specificity (0.84 and 0.79, respectively), indicating that whole body BMD could be used for screening osteoporosis. (author)

  15. A COMPARATIVE STUDY OF WHOLE-BODY VIBRATION EXPOSURE IN TRAIN AND CAR PASSENGERS: A CASE STUDY IN MALAYSIA

    Directory of Open Access Journals (Sweden)

    M.M. Rahman

    2011-12-01

    Full Text Available Trains and cars are the most important modes of transportation throughout the world. In highly developed countries, trains have become essential for human use as the most well-known form of public transportation, whereas the car plays a significant role in prompt human travel from one place to another. The high magnitude of vibration caused by trains and cars may cause health problems in humans, especially low back pain. The aim of this study was to evaluate and validate the values of daily exposure to vibration A(8 and the vibration dose value (VDV in passengers travelling by train and car and to assess the effects produced by this exposure on the human body. Moreover, this study introduces a newly developed whole-body vibration measurement instrumentation system. One train travelling from the east coast to the south of Malaysia was chosen to conduct the study. Whole-body vibration exposure was measured over 8 hours, which is equal to the duration of normal occupational exposure. One car was chosen randomly and whole-body vibration exposure was measured for 5 min and 10 min. All the data were computed using an IEPE(ICPTM accelerometer sensor connected to a DT9837 device which is capable of effectively measuring and analysing vibration. The vibration results were displayed on a personal computer using a custom graphical user interface (GUI. Matlab software was used to interpret the data. From the results, the whole-body vibration exposure level could be determined. It can be concluded that the whole-body vibration absorbed by the human body is enhanced when the magnitude of the vibration exposure experienced by the passengers increased. This was shown by the increased values of daily exposure to vibration A(8 and VDV calculated in the study.

  16. Effects of local and whole body irradiation on appearance of osteoclasts during wound healing of tooth extraction sockets in rats

    International Nuclear Information System (INIS)

    Hosokawa, Yoichiro; Sakakura, Yasunori; Tanaka, Likinobu; Okumura, Kazuhiko; Yajima, Toshihiko; Kaneko, Masayuki

    2007-01-01

    We examined effects of local and whole body irradiation before tooth extraction on appearance and differentiation of osteoclasts in the alveolar bone of rat maxillary first molars. Wistar rats weighting 100 g were divided into three groups: non-irradiation group, local irradiation group, and whole body irradiation group. In the local irradiation group, a field made with lead blocks was placed over the maxillary left first molar tooth. In the whole body irradiation group, the animals were irradiated in cages. Both groups were irradiated at 8 Gy. The number of osteoclasts around the interradicular alveolar bone showed chronological changes common to non-irradiated and irradiated animals. Several osteoclasts appeared one day after tooth extraction, and the maximal peak was observed 3 days after extraction. Local irradiation had no difference from non-irradiated controls. In animals receiving whole body irradiation, tooth extraction one day after irradiation caused smaller number of osteoclasts than that 7 day after irradiation during the experimental period. Whole body-irradiated rats had small osteoclasts with only a few nuclei and narrow resorption lacunae, indicating deficiency of radioresistant osteoclast precursor cells. Injection of intact bone marrow cells to whole body-irradiated animals immediately after tooth extraction recovered to some content the number of osteoclasts. These findings suggest that bone resorption in the wound healing of alveolar socket requires radioresistant, postmitotic osteoclast precursor cells from hematopoietic organs, but not from local sources around the alveolar socket, at the initial phase of wound healing. (author)

  17. Effects of local and whole body irradiation on appearance of osteoclasts during wound healing of tooth extraction sockets in rats.

    Science.gov (United States)

    Hosokawa, Yoichiro; Sakakura, Yasunori; Tanaka, Likinobu; Okumura, Kazuhiko; Yajima, Toshihiko; Kaneko, Masayuki

    2007-07-01

    We examined effects of local and whole body irradiation before tooth extraction on appearance and differentiation of osteoclasts in the alveolar bone of rat maxillary first molars. Wistar rats weighting 100 g were divided into three groups: non-irradiation group, local irradiation group, and whole body irradiation group. In the local irradiation group, a field made with lead blocks was placed over the maxillary left first molar tooth. In the whole body irradiation group, the animals were irradiated in cages. Both groups were irradiated at 8 Gy. The number of osteoclasts around the interradicular alveolar bone showed chronological changes common to non-irradiated and irradiated animals. Several osteoclasts appeared one day after tooth extraction, and the maximal peak was observed 3 days after extraction. Local irradiation had no difference from non-irradiated controls. In animals receiving whole body irradiation, tooth extraction one day after irradiation caused smaller number of osteoclasts than that 7 day after irradiation during the experimental period. Whole body-irradiated rats had small osteoclasts with only a few nuclei and narrow resorption lacunae, indicating deficiency of radioresistant osteoclast precursor cells. Injection of intact bone marrow cells to whole body-irradiated animals immediately after tooth extraction recovered to some content the number of osteoclasts. These findings suggest that bone resorption in the wound healing of alveolar socket requires radioresistant, postmitotic osteoclast precursor cells from hematopoietic organs, but not from local sources around the alveolar socket, at the initial phase of wound healing.

  18. Influence of pregnancy stage and fetus position on the whole-body and local exposure of the fetus to RF-EMF

    International Nuclear Information System (INIS)

    Varsier, N; Wiart, J; Dahdouh, S; Angelini, E D; Bloch, I; Serrurier, A; De la Plata, J-P; Anquez, J

    2014-01-01

    This paper analyzes the influence of pregnancy stage and fetus position on the whole-body and brain exposure of the fetus to radiofrequency electromagnetic fields. Our analysis is performed using semi-homogeneous pregnant woman models between 8 and 32 weeks of amenorrhea. By analyzing the influence of the pregnancy stage on the environmental whole-body and local exposure of a fetus in vertical position, head down or head up, in the 2100 MHz frequency band, we concluded that both whole-body and average brain exposures of the fetus decrease during the first pregnancy trimester, while they advance during the pregnancy due to the rapid weight gain of the fetus in these first stages. From the beginning of the second trimester, the whole-body and the average brain exposures are quite stable because the weight gains are quasi proportional to the absorbed power increases. The behavior of the fetus whole-body and local exposures during pregnancy for a fetus in the vertical position with the head up were found to be of a similar level, when compared to the position with the head down they were slightly higher, especially in the brain. (paper)

  19. Proton beam therapy how protons are revolutionizing cancer treatment

    CERN Document Server

    Yajnik, Santosh

    2013-01-01

    Proton beam therapy is an emerging technology with promise of revolutionizing the treatment of cancer. While nearly half of all patients diagnosed with cancer in the US receive radiation therapy, the majority is delivered via electron accelerators, where photons are used to irradiate cancerous tissue. Because of the physical properties of photon beams, photons may deposit energy along their entire path length through the body. On the other hand, a proton beam directed at a tumor travels in a straight trajectory towards its target, gives off most of its energy at a defined depth called the Bragg peak, and then stops. While photons often deposit more energy within the healthy tissues of the body than within the cancer itself, protons can deposit most of their cancer-killing energy within the area of the tumor. As a result, in the properly selected patients, proton beam therapy has the ability to improve cure rates by increasing the dose delivered to the tumor and simultaneously reduce side-effects by decreasing...

  20. Whole body MRI in the diagnosis of chronic recurrent multifocal osteomyelitis.

    LENUS (Irish Health Repository)

    Kennedy, M T

    2012-06-01

    Chronic recurrent multifocal osteomyelitis (CRMO) is a diagnosis of exclusion primarily in children and adolescents. As part of the essential criteria for the diagnosis of CRMO, multifocal lesions must be identified. We present the case of an 11-year-old boy with CRMO, whose diagnosis was facilitated by the use of whole body magnetic resonance imaging (WBMR), but not isotope bone scanning.

  1. Effect of whole body resistance training on arterial compliance in young men.

    NARCIS (Netherlands)

    Rakobowchuk, M.; McGowan, C.L.; Groot, P.C.E. de; Bruinsma, D.; Hartman, J.W.; Phillips, S.M.; MacDonald, M.J.

    2005-01-01

    The effect of resistance training on arterial stiffening is controversial. We tested the hypothesis that resistance training would not alter central arterial compliance. Young healthy men (age, 23 +/- 3.9 (mean +/- s.e.m.) years; n = 28,) were whole-body resistance trained five times a week for 12

  2. DETECTION OF WHOLE BODY OXIDATIVE STRESS IN URINE USING OXYGEN-18 LABELING

    Science.gov (United States)

    DETECTION OF WHOLE BODY OXIDATIVE STRESS IN URINE USING OXYGEN-18 LABELING. R Slade, J L McKee and G E Hatch. PTB, ETD, NHEERL, ORD, USEPA, Research Triangle Park, NC, USA.Reliable non-invasive markers for detecting oxidative stress in vivo are currently not available. We pr...

  3. Estimation of normal hydration in dialysis patients using whole body and calf bioimpedance analysis

    International Nuclear Information System (INIS)

    Zhu, Fansan; Kotanko, Peter; Handelman, Garry J; Raimann, Jochen G; Liu, Li; Carter, Mary; Kuhlmann, Martin K; Seibert, Eric; Levin, Nathan W; Leonard, Edward F

    2011-01-01

    Prescription of an appropriate dialysis target weight (dry weight) requires accurate evaluation of the degree of hydration. The aim of this study was to investigate whether a state of normal hydration (DW cBIS ) as defined by calf bioimpedance spectroscopy (cBIS) and conventional whole body bioimpedance spectroscopy (wBIS) could be characterized in hemodialysis (HD) patients and normal subjects (NS). wBIS and cBIS were performed in 62 NS (33 m/29 f) and 30 HD patients (16 m/14 f) pre- and post-dialysis treatments to measure extracellular resistance and fluid volume (ECV) by the whole body and calf bioimpedance methods. Normalized calf resistivity (ρ N,5 ) was defined as resistivity at 5 kHz divided by the body mass index. The ratio of wECV to total body water (wECV/TBW) was calculated. Measurements were made at baseline (BL) and at DW cBIS following the progressive reduction of post-HD weight over successive dialysis treatments until the curve of calf extracellular resistance is flattened (stabilization) and the ρ N,5 was in the range of NS. Blood pressures were measured pre- and post-HD treatment. ρ N,5 in males and females differed significantly in NS. In patients, ρ N,5 notably increased with progressive decrease in body weight, and systolic blood pressure significantly decreased pre- and post-HD between BL and DW cBIS respectively. Although wECV/TBW decreased between BL and DW cBIS , the percentage of change in wECV/TBW was significantly less than that in ρ N,5 (−5.21 ± 3.2% versus 28 ± 27%, p < 0.001). This establishes the use of ρ N,5 as a new comparator allowing a clinician to incrementally monitor removal of extracellular fluid from patients over the course of dialysis treatments. The conventional whole body technique using wECV/TBW was less sensitive than the use of ρ N,5 to measure differences in body hydration between BL and DW cBIS

  4. Clinical evaluation of exercise thallium-201 whole body scintigraphy in ischemic heart disease

    International Nuclear Information System (INIS)

    Kaneko, Kenzo; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    To evaluate whole body distribution and kinetics of Thallium-201 at exercise and redistribution, whole body scintigraphy (WB-S) was performed on 12 normal subjects (N), 19 patients with angina pectoris (AP) and 18 patients with old myocardial infarction (MI). WB-S was obtained using a gamma camera OMEGA 500 and analized by ADAC System IV. We estimated the following parameters from WB-S; 1) %Distribution (%D): the ratio of whole body counts to organ counts 2) washout rate (WR) in each organ. %D of the heart in N, AP and MI was similar at rest and exercise. At exercise, %D of the lung and the liver decreased and %D of thighs increased remarkably than at rest. At supine exercise, the lung indicated high %D and thinghs indicated low %D compared with at upright exercise. WR of the heart in AP and MI was significantly lower than in N (p<0.005, p<0.01) and further decreased proportionally to the number of stenotic coronary arteries and related to the ischemic ST depression of exercise ECG. WR of the heart was not correlation with pressure rate product and this finding suggested that WR of the heart was not prescribed by the tolerance of exercise but related to coronary flow at exercise a certain degree. WR of the lung in MI was significantly higher (p<0.025) and WR of thighs in AP and MI was significantly lower (p<0.025, p<0.05) compared with N. (author)

  5. Short duration small sided football and to a lesser extent whole body vibration exercise induce acute changes in markers of bone turnover

    DEFF Research Database (Denmark)

    Bowtell, Joanna L.; Jackman, Sarah R; Scott, Suzanne

    2016-01-01

    .8 ± 15.1 to 36.6 ± 14.7 μg·L(-1), P > 0.05). An increase in osteocalcin was observed 48 h after exercise (P type 1 collagen was not affected by exercise. Blood lactate concentration increased during exercise for FG15 (0......) small sided football or low magnitude whole body vibration training (VIB). Procollagen type 1 amino-terminal propeptide (P1NP) was increased during exercise for FG15 (51.6 ± 23.0 to 56.5 ± 22.5 μg·L(-1), mean ± SD, P

  6. Comparison of whole-body vibration exercise and plyometric exercise to improve isokinetic muscular strength, jumping performance and balance of female volleyball players.

    Science.gov (United States)

    Kim, Yong-Youn; Park, Si-Eun

    2016-11-01

    [Purpose] The purpose of this study was to assess the effect of whole-body vibration exercise and plyometric exercise on female volleyball players. [Subjects and Methods] Subjects were randomly allocated to two exercise groups (whole-body vibration exercise group and plyometric exercise group). The exercise was conducted three times each week for 8 weeks. Isokinetic muscular strength, jumping performance, and balance were measured before starting the exercise and after finishing the 8 weeks of exercise. [Results] Measurements of isokinetic muscular strength revealed that the whole-body vibration exercise group showed significant increase after the exercise. However, the plyometric exercise group had no significant increase in lumbar flexion, extension, and knee flexion. Measurements of vertical jumping revealed that, the whole-body vibration exercise group had no significant increase after the exercise. However, the plyometric exercise group showed significant increase. Measurements of balance revealed that, the whole-body vibration exercise group showed significant increase. However, the plyometric exercise group showed no significant increase. [Conclusion] Although both whole-body vibration and plyometric exercises are effective intervention methods, the two methods have different effects on the improvement of isokinetic muscular strength, jumping performance, and balance of female volleyball players.

  7. Factors affecting gastric uptake in whole body FDG-PET imaging

    International Nuclear Information System (INIS)

    Tomemori, Takashi; Kitagawa, Mami; Nakahara, Tadaki; Wu, Jin; Nakagawa, Keiichi; Uno, Kimiichi; Abe, Kinji; Tomiyoshi, Katsumi

    2001-01-01

    Positron emission tomography (PET) using 2-deoxy-2-[ 18 F]-fluoro-D-glucose (FDG) is very useful for the detection and staging of tumors. However, FDG is also accumulated in the normal tissues in various degrees. This physiological FDG uptake is often seen in intestine, making confusion with malignant tumor. The aim of this study was to identify factors influencing physiological FDG uptake in the stomach. A total of 136 people who underwent cancer screening or staging of tumors except for gastric cancer using FDG whole-body PET was examined (mean age: 55.6 yrs). All subjects fasted for at least 4 hours before the PET study and were administrated with FDG intravenously (mean FDG dose: 308.9 MBq). Emission images were acquired on a whole-body PET scanner and images were reconstructed without attenuation correction. The intensity of gastric uptake of FDG whole-body PET image was visually classified into 3 grades; grade 2 = the intensity of gastric uptake more than pulmonary uptake, grade 1 = the intensity of gastric uptake equal to or less than pulmonary uptake, grade 0 = no contrast between gastric uptake and background. Twenty-eight subjects (20.6%) were classified into grade 2, 42 subjects (30.9%) were grade 1 and 66 subjects (48.5%) were grade 0. Subjects' age, fasting time, FDG dose, serum glucose level, free fatty acid level and insulin level were not significantly correlated with the intensity of gastric uptake. But the subjects with higher gastric uptake tended to have anti-Helicobactor pylori (H. pylori) antibodies. The rate of having anti-H.pylori antibodies in the grade 2 group is significantly higher than the grade 1 group (85.7% vs. 72.5%, p<0.05), and that of the grade 1 group is significantly higher than the grade 0 group (72.5% vs. 42.2%, p<0.01). Gastric uptake was observed in about half of subjects. Especially, approximately 20% of all showed high gastric uptake, which was associated with H.pylori infection. Therefore, most of the subjects with high

  8. Factors affecting gastric uptake in whole body FDG-PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tomemori, Takashi; Kitagawa, Mami; Nakahara, Tadaki; Wu, Jin; Nakagawa, Keiichi; Uno, Kimiichi; Abe, Kinji; Tomiyoshi, Katsumi [Nishidai Clinic Diagnostic Imaging Center, Tokyo (Japan)

    2001-06-01

    Positron emission tomography (PET) using 2-deoxy-2-[{sup 18}F]-fluoro-D-glucose (FDG) is very useful for the detection and staging of tumors. However, FDG is also accumulated in the normal tissues in various degrees. This physiological FDG uptake is often seen in intestine, making confusion with malignant tumor. The aim of this study was to identify factors influencing physiological FDG uptake in the stomach. A total of 136 people who underwent cancer screening or staging of tumors except for gastric cancer using FDG whole-body PET was examined (mean age: 55.6 yrs). All subjects fasted for at least 4 hours before the PET study and were administrated with FDG intravenously (mean FDG dose: 308.9 MBq). Emission images were acquired on a whole-body PET scanner and images were reconstructed without attenuation correction. The intensity of gastric uptake of FDG whole-body PET image was visually classified into 3 grades; grade 2 = the intensity of gastric uptake more than pulmonary uptake, grade 1 = the intensity of gastric uptake equal to or less than pulmonary uptake, grade 0 = no contrast between gastric uptake and background. Twenty-eight subjects (20.6%) were classified into grade 2, 42 subjects (30.9%) were grade 1 and 66 subjects (48.5%) were grade 0. Subjects' age, fasting time, FDG dose, serum glucose level, free fatty acid level and insulin level were not significantly correlated with the intensity of gastric uptake. But the subjects with higher gastric uptake tended to have anti-Helicobactor pylori (H. pylori) antibodies. The rate of having anti-H.pylori antibodies in the grade 2 group is significantly higher than the grade 1 group (85.7% vs. 72.5%, p<0.05), and that of the grade 1 group is significantly higher than the grade 0 group (72.5% vs. 42.2%, p<0.01). Gastric uptake was observed in about half of subjects. Especially, approximately 20% of all showed high gastric uptake, which was associated with H.pylori infection. Therefore, most of the subjects

  9. Whole-body kinetics and dosimetry of cis-4-[18F]fluoro-l-proline

    International Nuclear Information System (INIS)

    Boerner, Anne R.; Langen, Karl-J.; Herzog, Hans; Hamacher, Kurt; Mueller-Mattheis, Volker; Schmitz, Thomas; Ackermann, Rolf; Coenen, Heinz H.

    2001-01-01

    The whole-body distribution of 4-cis[ 18 F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 μGy/MBq). The effective dose according to ICRP 60 was 15.1 μSv/MBq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro

  10. Whole-body kinetics and dosimetry of cis-4-[(18)F]fluoro-L-proline.

    Science.gov (United States)

    Börner, A R; Langen, K J; Herzog, H; Hamacher, K; Müller-Mattheis, V; Schmitz, T; Ackermann, R; Coenen, H H

    2001-04-01

    The whole-body distribution of 4-cis[(18)F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 microGy/mbq). The effective dose according to ICRP 60 was 15.1 microSv/mbq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro.

  11. Whole-body magnetic resonance angiography of patients using a standard clinical scanner

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Tomas; Wikstroem, Johan; Eriksson, Mats-Ola; Lundberg, Anders; Ahlstroem, Haakan [Uppsala University Hospital, Department of Diagnostic Radiology, Uppsala (Sweden); Johansson, Lars [Uppsala University Hospital, Uppsala (Sweden); Ljungman, Christer [Uppsala University Hospital, Department of Vascular Surgery, Uppsala (Sweden); Hoogeven, Romhild [Philips Medical Systems, MR Clinical Science, Best (Netherlands)

    2006-01-01

    The purpose of this study was to evaluate the technique of whole-body magnetic resonance angiography (MRA) of patients with a standard clinical scanner. Thirty-three patients referred for stenoses, occlusions, aneurysms, assessment of patency of vascular grafts, vasculitis and vascular aplasia were examined in a 1.5-T scanner using its standard body coil. Three-dimensional sequences were acquired in four stations after administration of one intravenous injection of 40 ml conventional gadolinium contrast agent. Different vessel segments were evaluated as either diagnostic or nondiagnostic and regarding the presence of stenoses with more than 50% diameter reduction, occlusions or aneurysms. Of 923 vessel segments, 67 were not evaluable because of poor contrast filling (n=31), motion artefacts (n=20), venous overlap (n=12) and other reasons (n=4). Stenoses of more than 50%, occlusions or aneurysms were observed in 26 patients (129 segments). In nine patients additional unsuspected pathology was found. In 10 out of 14 patients (71/79 segments) there was conformity between MRA and digital subtraction angiography regarding the grade of stenosis. This study shows that whole-body MRA with a standard clinical scanner is feasible. Motion artefacts and the timing of the contrast agent through the different segments are still problems to be solved. (orig.)

  12. Treatment planning, optimization, and beam delivery technqiues for intensity modulated proton therapy

    Science.gov (United States)

    Sengbusch, Evan R.

    , beamlet weight, the number of delivered beamlets, and the number of delivery angles. These methods are evaluated via treatment planning studies including left-sided whole breast irradiation, lung stereotactic body radiotherapy, nasopharyngeal carcinoma, and whole brain radiotherapy with hippocampal avoidance. Improvements in efficiency and efficacy relative to traditional proton therapy and intensity modulated photon radiation therapy are discussed.

  13. Lightweight Vehicle and Driver’s Whole-Body Models for Vibration Analysis

    Science.gov (United States)

    MdSah, Jamali; Taha, Zahari; Azwan Ismail, Khairul

    2018-03-01

    Vehicle vibration is a main factor for driving fatigue, discomfort and health problems. The ability to simulate the vibration characteristics in the vehicle and its effects on driver’s whole-body vibration will give significant advantages to designers especially on the vehicle development time and cost. However, it is difficult to achieve optimal condition of ride comfort and handling when using passive suspension system. This paper presents mathematical equations that can be used to describe the vibration characteristics of a lightweight electric vehicle that had been developed. The vehicle’s model was combined with the lumped-parameter model of driver to determine the whole-body vibration level when the vehicle is passing over a road hump using Matlab Simulink. The models were simulated at a constant speed and the results were compared with the experimental data. The simulated vibration level at the vehicle floor and seat were almost similar to the experimental vibration results. The suspension systems that are being used for the solar vehicle are able to reduce the vibration level due to the road hump. The models can be used to simulate and choose the optimal parameters for the suspensions.

  14. Plutonium fecal and urinary excretion functions: Derivation from a systematic whole-body retention function

    International Nuclear Information System (INIS)

    Sun, C.; Lee, D.

    1999-01-01

    Liver-bile secretion directly influences the content of plutonium in feces. To assess the reliability of plutonium metabolic models and to improve the accuracy of interpreting plutonium fecal data, the authors developed a compartmental model that simulates the metabolism of plutonium in humans. With this model, they can describe the transport of plutonium contaminants in the systemic organs and tissues of the body, including fecal and urine excretions, without using elaborate kinetic information. The parameter values of the models, which describe the translocation rates and recycling of plutonium in the body, can be derived from a multi-term exponential systemic function for whole-body retention. The analytical derivations and algorithms for solving translocation parameter values are established for the model and illustrated by applying them to the biokinetics and bioassay of plutonium. This study describes how to (1) design a physiological model for incorporating liver biliary secretion and for obtaining a fecal-excretion function, (2) develop an analytical solution for identifying the translocation-parameter values incorporating the recycling of plutonium in the body, and (3) derive a set of urinary and fecal excretion-functions from a published systemic whole-body retention function, generally acknowledged to be accurate, as a real and practical example

  15. Long-term effect of whole-body X-irradiation on cell-mediated immune reaction in mice

    International Nuclear Information System (INIS)

    Norimura, Toshiyuki; Tsuchiya, Takehiko

    1989-01-01

    Age-related change in immunological activity was examined at 10 to 91 weeks following whole-body irradiation by determining the specific anti-tumor cell-mediated immunity in host mice induced and/or enhanced by local irradiation to transplanted tumor. Median survival time of the non-irradiated C3H/He female mice was 98.6 weeks while the median life-span of the mice exposed to two and four Gy of 250 kVp X-rays at the age of 10-12 weeks was shortened by 14.9 and 23.4 weeks, respectively. The rate of tumor reduction within two weeks after local irradiation to tumor and the growth inhibitory activitiy of spleen cells from tumor irradiated mice were reduced in a dose-dependent manner when assessed 10 weeks after whole-body irradiation, but recovered to the near-complete level of the non-irradiated controls within a few months, then gradually decreased with normal aging. These results suggest that the age-dependent decline of this immunological activity apears earlier in the irradiated mice as a result of whole-body X-irradiation at a young age, suggesting accelerated aging of the immune system. (author)

  16. Whole-body magnetic resonance angiography for presurgical planning of free-flap head and neck reconstruction

    International Nuclear Information System (INIS)

    Kramer, Manuel; Nkenke, Emeka; Kikuchi, Keiichi; Schwab, Siegfried A.; Janka, Rolf; Uder, Michael; Lell, Michael

    2012-01-01

    Objectives: Aim of the study was to evaluate if a whole-body magnetic resonance angiography (MRA) protocol meets the requirements to evaluate the donor and host site target vessels for planning of microvascular head and neck reconstructions. Patients and methods: In 20 patients, scheduled for reconstruction of the mandible with fibular free flaps, contrast-enhanced whole-body MRA was performed prior to surgery. 32-Channel 1.5-T MR angiograms were acquired using a 2-step contrast (gadobutrol) injection scheme to visualize the arterial vasculature from head to feet. Maximum intensity projection and multiplanar reconstruction technique was employed to visualize MRA data. For image evaluation the arterial tree was divided into 51 segments. The presence of artefacts impairing diagnostic quality was noted. Evaluable segments were assessed regarding the presence of stenoses >50% diameter reduction, occlusions or aneurysms. Results: No adverse reactions or complications occurred. Of 1020 vessel segments 1003 (98.3%) were evaluable. 36 stenoses >50%, 50 occlusions and one aneurysm were observed. In 21 of 40 lower limbs relevant atherosclerotic changes were depicted. Conclusion: Whole-body MRA proved to be a suitable three-dimensional, noninvasive, nonionising modality for preoperative evaluation of the entire arterial vasculature.

  17. Acute central nervous system (CNS) toxicity of total body irradiation (TBI) measured using neuropsychological testing of attention functions

    International Nuclear Information System (INIS)

    Wenz, Frederik; Steinvorth, Sarah; Lohr, Frank; Hacke, Werner; Wannenmacher, Michael

    1999-01-01

    Purpose: The purpose of this study was to investigate acute normal tissue damage of low irradiation doses to the healthy, adult central nervous system (CNS) using neuropsychological testing of attention functions. Methods and Materials: Neuropsychological testing (IQ, attention [modified Trail-Making Test A, Digit Symbol Test, D2 Test, Wiener Determination Machine]) was used to examine 40 patients (43 ± 10 years) before and immediately after the first fraction (1.2 Gy) of hyperfractionated total body irradiation (TBI) at the University of Heidelberg. The patients received antiemetic premedication. Test results are given as mean percentiles ± standard deviation, with 50 ± 34 being normal. Thirty-eight control patients (53 ± 15 years) were studied to quantify the influence of hospitalization, stress, and repeated testing. Results: The patients showed normal baseline test results (IQ = 101 ± 14, attention = 54 ± 28) and no decrease in test results after 1.2 Gy TBI. Attention functions improved (66 ± 25) corresponding to a practice effect of repeated testing that was seen in the control group, although alternate versions of the tests were used (IQ = 104 ± 10, attention before = 42 ± 29, attention after = 52 ± 31). Conclusion: Our data show no deterioration of neuropsychologic test results acutely after 1.2 Gy whole body exposure in adult patients without CNS disease receiving antiemetic medication

  18. Protective Role Of Fresh Pomegranate Against Oxidative Damage In Whole Body Gamma Irradiated Male Albino Rats

    International Nuclear Information System (INIS)

    Kassab, F.M.A.; Taha, M.S.

    2013-01-01

    Twenty four male albino rats, body weight 100-130 g, were used to evaluate the protective role of fresh pomegranate fruit intake for 30 days on the damage induced by single dose of 6 Gy whole body gamma irradiation. The rats were randomly and equally divided into four groups: group (1): control, group (2): irradiated with 6 Gy, group (3): pomegranate for 30 days and group (4): pomegranate for 30 days followed by 6 Gy whole body irradiation. At the end of the experiment, all rats were sacrificed after 12 hours fasting then sera were separated for the determination of sugar, total antioxidant, lipid profile and liver and kidney functions. Results showed that gamma radiation caused significant decline (P<0.05) in serum total antioxidant, total protein, albumin, HDL-C and blood glucose with significant elevation (P<0.05) in other hepato-renal markers in addition to serum total cholesterol, triglycerides and LDL-C. These changes were significantly attenuated in irradiated animals pre-treated with whole fresh pomegranate fruit leading to the conclusion that pre-intake of pomegranate fruit had a radio- protective effect. This protection of this whole fruit may be due to the increased total antioxidant level leading to free radical scavenging

  19. Vibration energy absorption in the whole-body system of a tractor operator

    Directory of Open Access Journals (Sweden)

    Jan Szczepaniak

    2014-06-01

    Full Text Available Many people are exposed to whole-body vibration (WBV in their occupational lives, especially drivers of vehicles such as tractor and trucks. The main categories of effects from WBV are perception degraded comfort interference with activities-impaired health and occurrence of motion sickness. Absorbed power is defined as the power dissipated in a mechanical system as a result of an applied force. The vibration-induced injuries or disorders in a substructure of the human system are primarily associated with the vibration power absorption distributed in that substructure. The vibration power absorbed by the exposed body is a measure that combines both the vibration hazard and the biodynamic response of the body. The article presents measurement method for determining vibration power dissipated in the human whole body system called Vibration Energy Absorption (VEA. The vibration power is calculated from the real part of the force-velocity cross-spectrum. The absorbed power in the frequency domain can be obtained from the cross-spectrum of the force and velocity. In the context of the vibration energy transferred to a seated human body, the real component reflects the energy dissipated in the biological structure per unit of time, whereas the imaginary component reflects the energy stored/released by the system. The seated human is modeled as a series/parallel 4-DOF dynamic models. After introduction of the excitation, the response in particular segments of the model can be analyzed. As an example, the vibration power dissipated in an operator has been determined as a function of the agricultural combination operating speed 1.39 – 4.16 ms[sup] -1 [/sup].

  20. Development of the Discrimination Programs between the Internal and External Radioactive Contamination of Workers Using a Whole Body Counter

    International Nuclear Information System (INIS)

    Kong, T. Y.; Kim, H. G.; Lim, S. N.; Kim, H. J.; Jin, H. H.; Lee, S. G.; Park, S. C.

    2006-01-01

    A whole body counter (WBC) is used to identify and measure the radioactivity in the body of human beings in a nuclear power plant (NPP). In domestic NPPs, several whole body counters are in operation to monitor the internal radioactive contamination of workers. All workers take a whole body counting after radiation works if there is high possibility of radioactive contamination or the radioactivity is detected by portal monitoring. It is, however, found that the external contamination is occasionally estimated as the internal radioactive contamination. In this case, the worker is recommended to take showers for the decontamination of skin and take a whole body counting again. Although the detected radioactivity is reduced remarkably after several decontaminations, confirmed as the external contamination, it is determined finally as an internal contamination if the radioactivity is still detected in the body of worker. The amount of detected radioactivity can be much higher than that of the expected for this mistaken contamination since the radioisotopes attached to skin come to be close to the detectors of WBC. Finally, this makes not only the misjudgment of the external contamination as the internal contamination, but also the excessively conservative estimation of radioactive contamination. In this study, several experiments were carried out to set up the discrimination program between the internal and external radioactive contamination using the humanoid phantom and a whole body counter. After the analysis of experimental results, we found that the use of front and backside counts could be applied to the discrimination of the external contamination and the ratio of detected radioactivities between front and backside counts was more than about factor 2 for the external contamination

  1. Whole-Body Vibration Training Improves Heart Rate Variability and Body Fat Percentage in Obese Hispanic Postmenopausal Women.

    Science.gov (United States)

    Severino, Gregory; Sanchez-Gonzalez, Marcos; Walters-Edwards, Michelle; Nordvall, Michael; Chernykh, Oksana; Adames, Jason; Wong, Alexei

    2017-07-01

    The present study examined the effects of a 6-week whole-body vibration training (WBVT) regimen on heart rate variability (HRV) and body composition in obese Hispanic postmenopausal women. Participants were randomly assigned to either WBVT (n = 13) or a nonexercising control group (n = 14). HRV and body composition were measured before and after 6 weeks. There was a significant group by time interaction (P < .05) for heart rate, sympathovagal balance, and body fat percentage (BF%) such that all significantly decreased (P < .05); and R-R intervals significantly increased (P < .05) following WBVT compared to no changes after control. The changes in sympathovagal balance were correlated with changes in BF% (r = .63, P < .05). Our findings indicate that WBVT improves HRV and BF% in obese Hispanic postmenopausal women. The improvement in BF% partially explained the decrease in sympathovagal balance. Since obese and older individuals are at increased risk of developing cardiovascular diseases, they could potentially benefit from WBVT.

  2. Patient-Specific Biomechanical Model as Whole-Body CT Image Registration Tool

    OpenAIRE

    Li, Mao; Miller, Karol; Joldes, Grand Roman; Doyle, Barry; Garlapati, Revanth Reddy; Kikinis, Ron; Wittek, Adam

    2015-01-01

    Whole-body computed tomography (CT) image registration is important for cancer diagnosis, therapy planning and treatment. Such registration requires accounting for large differences between source and target images caused by deformations of soft organs/tissues and articulated motion of skeletal structures. The registration algorithms relying solely on image processing methods exhibit deficiencies in accounting for such deformations and motion. We propose to predict the deformations and moveme...

  3. Command Recognition of Robot with Low Dimension Whole-Body Haptic Sensor

    Science.gov (United States)

    Ito, Tatsuya; Tsuji, Toshiaki

    The authors have developed “haptic armor”, a whole-body haptic sensor that has an ability to estimate contact position. Although it is developed for safety assurance of robots in human environment, it can also be used as an interface. This paper proposes a command recognition method based on finger trace information. This paper also discusses some technical issues for improving recognition accuracy of this system.

  4. Whole-body profile scanner for in vivo quantitative activity measurement

    International Nuclear Information System (INIS)

    Bergmann, H.

    1978-01-01

    A whole-body profile scanner has been developed by fitting parallel slit collimators to a shadow shield whole-body counter. Sensitivity, uniformity and resolution measurements were performed using a number of different counting conditions. It is shown that improved accuracy of activity measurements is obtained by using a wide window counting technique for low and medium energy gamma emitters (99m Tc, 131 I), whereas a photopeak window should be used for high energy gamma emitters (47 Ca). Due to the finite spatial resolution of the system a systematic error in evaluating regional activities from the counting rate profile occurs which is characterized by a spatial spillover factor. The spatial spillover factor is measured and is subsequently used to calculate the error on basis of a simple model. It is shown that only small errors are caused by spatial spillover when the length of a region is at least three times the full width half maximum of the point spread function. Applying the above mentioned simple rules it is concluded that profile scanning is a sensitive and accurate technique for activity measurements in vivo. Two examples of clinical applications (measurement of bone accretion rates of calcium and Tc-pyrophosphate, regional radioiodine retention in patients with thyroid carcinoma) and a review of the papers on profile scanning demonstrate the types of investigations in which profile scanning is superior to alternative techniques. (author)

  5. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  6. Comparison of proton therapy techniques for treatment of the whole brain as a component of craniospinal radiation.

    Science.gov (United States)

    Dinh, Jeffrey; Stoker, Joshua; Georges, Rola H; Sahoo, Narayan; Zhu, X Ronald; Rath, Smruti; Mahajan, Anita; Grosshans, David R

    2013-12-17

    For treatment of the entire cranium using passive scattering proton therapy (PSPT) compensators are often employed in order to reduce lens and cochlear exposure. We sought to assess the advantages and consequences of utilizing compensators for the treatment of the whole brain as a component of craniospinal radiation (CSI) with PSPT. Moreover, we evaluated the potential benefits of spot scanning beam delivery in comparison to PSPT. Planning computed tomography scans for 50 consecutive CSI patients were utilized to generate passive scattering proton therapy treatment plans with and without Lucite compensators (PSW and PSWO respectively). A subset of 10 patients was randomly chosen to generate scanning beam treatment plans for comparison. All plans were generated using an Eclipse treatment planning system and were prescribed to a dose of 36 Gy(RBE), delivered in 20 fractions, to the whole brain PTV. Plans were normalized to ensure equal whole brain target coverage. Dosimetric data was compiled and statistical analyses performed using a two-tailed Student's t-test with Bonferroni corrections to account for multiple comparisons. Whole brain target coverage was comparable between all methods. However, cribriform plate coverage was superior in PSWO plans in comparison to PSW (V95%; 92.9 ± 14 vs. 97.4 ± 5, p left; 24.8 ± 0.8 vs. 22.2 ± 0.7, p right; 25.2 ± 0.8 vs. 22.8 ± 0.7, p vs. PSWO (mean cochlea dose Gy(RBE): 36.4 ± 0.2 vs. 36.7 ± 0.1, p = NS). Moreover, dose homogeneity was inferior in PSW plans in comparison to PSWO plans as reflected by significant alterations in both whole brain and brainstem homogeneity index (HI) and inhomogeneity coefficient (IC). In comparison to both PSPT techniques, multi-field optimized intensity modulated (MFO-IMPT) spot scanning treatment plans displayed superior sparing of both lens and cochlea (max lens: 12.5 ± 0.6 and 12.9 ± 0.7 right and left respectively; mean cochlea 28.6

  7. Comparison of proton therapy techniques for treatment of the whole brain as a component of craniospinal radiation

    International Nuclear Information System (INIS)

    Dinh, Jeffrey; Stoker, Joshua; Georges, Rola H; Sahoo, Narayan; Zhu, X Ronald; Rath, Smruti; Mahajan, Anita; Grosshans, David R

    2013-01-01

    For treatment of the entire cranium using passive scattering proton therapy (PSPT) compensators are often employed in order to reduce lens and cochlear exposure. We sought to assess the advantages and consequences of utilizing compensators for the treatment of the whole brain as a component of craniospinal radiation (CSI) with PSPT. Moreover, we evaluated the potential benefits of spot scanning beam delivery in comparison to PSPT. Planning computed tomography scans for 50 consecutive CSI patients were utilized to generate passive scattering proton therapy treatment plans with and without Lucite compensators (PSW and PSWO respectively). A subset of 10 patients was randomly chosen to generate scanning beam treatment plans for comparison. All plans were generated using an Eclipse treatment planning system and were prescribed to a dose of 36 Gy(RBE), delivered in 20 fractions, to the whole brain PTV. Plans were normalized to ensure equal whole brain target coverage. Dosimetric data was compiled and statistical analyses performed using a two-tailed Student’s t-test with Bonferroni corrections to account for multiple comparisons. Whole brain target coverage was comparable between all methods. However, cribriform plate coverage was superior in PSWO plans in comparison to PSW (V95%; 92.9 ± 14 vs. 97.4 ± 5, p < 0.05). As predicted, PSWO plans had significantly higher lens exposure in comparison to PSW plans (max lens dose Gy(RBE): left; 24.8 ± 0.8 vs. 22.2 ± 0.7, p < 0.05, right; 25.2 ± 0.8 vs. 22.8 ± 0.7, p < 0.05). However, PSW plans demonstrated no significant cochlear sparing vs. PSWO (mean cochlea dose Gy(RBE): 36.4 ± 0.2 vs. 36.7 ± 0.1, p = NS). Moreover, dose homogeneity was inferior in PSW plans in comparison to PSWO plans as reflected by significant alterations in both whole brain and brainstem homogeneity index (HI) and inhomogeneity coefficient (IC). In comparison to both PSPT techniques, multi-field optimized intensity modulated (MFO-IMPT) spot

  8. Quantitative determination of blood losses by a whole-body counter

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Garreta, A.C. de; Soria, N.; Blanco, E.

    1976-01-01

    A method to quantitate blood losses by determination of the 51 Cr whole body retention (WBR) was developed. Autologous red cells labelled with Na 2 O 4 51 Cr were given intravenously. Blood losses were simulated by withdrawing blood samples. Percent relative variation (PRV) between real blood losses (blood withdrawal) and blood losses calculated by determining the WBR, were found. Withdrawal of 60 ml blood gave a PRV lower than 10.0%. 51 Cr body loss due to elution and red cell death was found to be 0.017 day -1 . The method allows the accurate detection of total blood losses of 60 ml or more, and it can be used to quantitate gastrointestinal or gynecological hemorrhages, avoiding the inconveniences involved by the complete recolection of faeces or of towels and tampons. (author) [es

  9. Reconstruction of a whole-body counter into a process computer-controlled low-level whole-body scanner

    International Nuclear Information System (INIS)

    Hamann, C.

    1975-01-01

    A report is given on the state of the research project to reconstruct our whole-body counter with solid geometries into a scanning type one. The object is to develop a process computer controlled 'adaptive system'. The self-built scan mechanics are explained and the advantages and problems of applying stepping motors are gone into. A stepping motor coordinates control is presented. As the planned scanner and the process computer form a digital controlled system, all theoretical and actual values as well as the control orders from the process computer must be directly controllable. A CAMAC system was not used for economical reasons, the process periphery was made controllable by self building of interfaces to and from the computer. As example, the available multi-channel analyzers were converted to external controlling. The price-moderate and relatively simple self-built set-up are outlined and an example is given of how a TELETYPE version is reconstructed into a fast electronic interface. A BUS-MULTIPLEX system was developed which generates all necessary DI/DO interfaces out of one DI and DO address of the process computer only. The essential part of this system is given. (orig./LH) [de

  10. Ustur whole body case 0269: demonstrating effectiveness of i.v. CA-DTPA for Pu

    Energy Technology Data Exchange (ETDEWEB)

    James, A.C.; Sasser, L.B.; Stuit, D.B. [US Transuranium and Uranium Registries, College of Pharmacy, Washington State University, 1845 Terminal Drive, Suite 201, Richland, WA 99354 (United States); Glover, S.E. [Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, 598 Rhodes Hall, Cincinnati, OH 45221 (United States); Carbaugh, E.H. [Pacific Northwest National Laboratory, PO Box 999, Richland, WA 99354 (United States)

    2007-07-01

    This whole body donation case (USTUR Registrant) involved a single acute inhalation of an acidic Pu(NO{sub 3}){sub 4} solution in the form of an aerosol 'mist'. Chelation treatment with intravenously (i.v.) Ca-EDTA was initiated on the day of the intake, and continued intermittently over 6 months. After 2.5 y with no further treatment, a course of i.v. Ca-DTPA was administered. A total of 400 measurements of {sup 239+240}Pu excreted in urine were recorded; starting on the first day (both before and during the initial Ca-EDTA chelation) and continuing for 37 y. This sampling included all intervals of chelation. In addition, 91 measurements of {sup 239+240}Pu-in-feces were recorded over this whole period. The Registrant died about 38 y after the intake, at age 79 y, with extensive carcinomatosis secondary to adenocarcinoma of the prostate gland. At autopsy, all major soft tissue organs were harvested for radiochemical analyses of their {sup 238}Pu, {sup 239+240}Pu and {sup 241}Am content. Also, all types of bone (comprising about half the skeleton) were harvested for radiochemical analyses, as well as samples of skin, subcutaneous fat and muscle. This comprehensive data set has been applied to derive 'chelation-enhanced' transfer rates in the ICRP Publication 67 plutonium biokinetic model, representing the behaviour of blood-borne and tissue-incorporated plutonium during intervals of therapy. The resulting model of the separate effects of i.v. Ca-EDTA and Ca-DTPA chelation shows that the therapy administered in this case succeeded in reducing substantially the long-term burden of plutonium in all body organs, except for the lungs. The calculated reductions in organ content at the time of death are {approx}40% for the liver, 60% for other soft tissues (muscle, skin, glands, etc.), 50% for the kidneys and 50% for the skeleton. Essentially, all of the substantial reduction in skeletal burden occurred in trabecular bone. This modelling exercise

  11. Aspects of the engineering design of whole-body nuclear magnetic resonance machines

    International Nuclear Information System (INIS)

    Young, I.R.; Collins, A.G.; Hall, A.S.; Harman, R.R.; Butson, P.C.; Gilderdale, D.J.

    1987-01-01

    The paper on whole-body nuclear magnetic resonance machines reviews the basic physics very briefly, then examines the design requirements and engineering constraints for the major components of such a system. The paper concludes with a brief resume of the techniques used, and a short presentation of the type of results that are achieved. (author)

  12. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2013-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaIT1 (8x4″), and thyroid one, NaIT1 (3x3″). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that wasn't exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2007 to December 2012, approximately 6700 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  13. Electron capture in proton collisions with alkali atoms as a three-body problem

    International Nuclear Information System (INIS)

    Avakov, G.V.; Blokhintsev, L.D.; Kadyrov, A.S.; Mukhamedzhanov, A.M.

    1992-01-01

    A previous paper proposed an approach to the calculation of electron transfer reactions in ion-atomic collisions based on the Faddeev three-body equations written in the Alt-Grassberger-Sandhas form. In the present work this approach is used to describe the electron capture in proton collisions with alkali atoms. The results of calculation of the total and partial cross sections for charge exchange in proton collisions with Li, Na, K and Rb atoms are presented. The calculated total cross sections are in good agreement with experiment for light target atoms. In going over to heavier targets, the theoretical total cross sections, while agreeing in form, tend to be larger than the experimental ones. The calculated partial cross sections for electron capture into the 2s state of the H atom are also in agreement with experiment. Some other partial cross sections were also calculated. (author)

  14. Whole-Body Vibrations Associated With Alpine Skiing: A Risk Factor for Low Back Pain?

    Directory of Open Access Journals (Sweden)

    Matej Supej

    2018-03-01

    Full Text Available Alpine skiing, both recreational and competitive, is associated with high rates of injury. Numerous studies have shown that occupational exposure to whole-body vibrations is strongly related to lower back pain and some suggest that, in particular, vibrations of lower frequencies could lead to overuse injuries of the back in connection with alpine ski racing. However, it is not yet known which forms of skiing involve stronger vibrations and whether these exceed safety thresholds set by existing standards and directives. Therefore, this study was designed to examine whole-body vibrations connected with different types of skiing and the associated potential risk of developing low back pain. Eight highly skilled ski instructors, all former competitive ski racers and equipped with five accelerometers and a Global Satellite Navigation System to measure vibrations and speed, respectively, performed six different forms of skiing: straight running, plowing, snow-plow swinging, basic swinging, short swinging, and carved turns. To estimate exposure to periodic, random and transient vibrations the power spectrum density (PSD and standard ISO 2631-1:1997 parameters [i.e., the weighted root-mean-square acceleration (RMS, crest factor, maximum transient vibration value and the fourth-power vibration dose value (VDV] were calculated. Ground reaction forces were estimated from data provided by accelerometers attached to the pelvis. The major novel findings were that all of the forms of skiing tested produced whole-body vibrations, with highest PSD values of 1.5–8 Hz. Intensified PSD between 8.5 and 35 Hz was observed only when skidding was involved. The RMS values for 10 min of short swinging or carved turns, as well as all 10-min equivalent VDV values exceeded the limits set by European Directive 2002/44/EC for health and safety. Thus, whole-body vibrations, particularly in connection with high ground reaction forces, contribute to a high risk for low back

  15. Effect of lowering dietary calcium intake on fractional whole body calcium retention

    International Nuclear Information System (INIS)

    Dawson-Hughes, B.; Stern, D.T.; Shipp, C.C.; Rasmussen, H.M.

    1988-01-01

    Although fractional calcium absorption is known to vary inversely with calcium intake, the extent and timing of individual hormonal and calcium absorption responses to altered calcium intake have not been defined. We measured fractional whole body retention of orally ingested 47 Ca, an index of calcium absorption, in nine normal women after they had eaten a 2000-mg calcium diet for 8 weeks and a 300-mg calcium diet for 1, 2, 4, and 8 weeks. After the diet change, serum intact PTH (32.2% increase; P = 0.005), serum 1,25-dihydroxyvitamin D [1,25-(OH)2D; 43.8% increase; P = 0.003], and fractional whole body calcium retention (42.8% increase; P = 0.004) increased within 1 week. Although the PTH and calcium retention responses remained fairly constant throughout the low calcium intake period, serum 1,25-(OH)2D concentrations declined toward baseline after week 1. Thus, the late increase in calcium retention may have resulted from calcium absorption that was independent of 1,25-(OH)2D stimulation

  16. A 4-Tesla superconducting whole-body magnet for MR imaging and spectroscopy

    International Nuclear Information System (INIS)

    Vetter, J.; Ries, G.; Reichert, T.

    1988-01-01

    Since January 87 a 4 tesla MR magnet with a 1.25 m diameter warm bore is in operation at the Siemens Research Laboratories. The magnet weighing 10 tons is part of a whole-body MR device devoted to in-vivo research studies at magnetic fields significantly higher than 2 tesla; the highest field strength presently used in standard MR whole-body systems. The stored energy of the adiabatically stable six-coil system is 39 MJ at 4 tesla. The rated current is 376 A. Superconducting and resistive shim-coils together with iron shims reduce the bare magnet inhomogeneity of 100 ppm down to less than 5 ppm in a 50 cm diameter spherical volume. The magnet operates in persistent mode with the current leads retracted. The field drift is less than 3 x 10/sup -8//h. A small helium refrigerator is used to cool both the two radiation shields of the cryostat and the current leads and to reliquify the evaporating helium gas. Results of coil design, analysis of forces and stresses, quench protection, cryostat design and magnet operation are reported

  17. Whole-body nanoparticle aerosol inhalation exposures.

    Science.gov (United States)

    Yi, Jinghai; Chen, Bean T; Schwegler-Berry, Diane; Frazer, Dave; Castranova, Vince; McBride, Carroll; Knuckles, Travis L; Stapleton, Phoebe A; Minarchick, Valerie C; Nurkiewicz, Timothy R

    2013-05-07

    Inhalation is the most likely exposure route for individuals working with aerosolizable engineered nano-materials (ENM). To properly perform nanoparticle inhalation toxicology studies, the aerosols in a chamber housing the experimental animals must have: 1) a steady concentration maintained at a desired level for the entire exposure period; 2) a homogenous composition free of contaminants; and 3) a stable size distribution with a geometric mean diameter generation of aerosols containing nanoparticles is quite challenging because nanoparticles easily agglomerate. This is largely due to very strong inter-particle forces and the formation of large fractal structures in tens or hundreds of microns in size (6), which are difficult to be broken up. Several common aerosol generators, including nebulizers, fluidized beds, Venturi aspirators and the Wright dust feed, were tested; however, none were able to produce nanoparticle aerosols which satisfy all criteria (5). A whole-body nanoparticle aerosol inhalation exposure system was fabricated, validated and utilized for nano-TiO2 inhalation toxicology studies. Critical components: 1) novel nano-TiO2 aerosol generator; 2) 0.5 m(3) whole-body inhalation exposure chamber; and 3) monitor and control system. Nano-TiO2 aerosols generated from bulk dry nano-TiO2 powders (primary diameter of 21 nm, bulk density of 3.8 g/cm(3)) were delivered into the exposure chamber at a flow rate of 90 LPM (10.8 air changes/hr). Particle size distribution and mass concentration profiles were measured continuously with a scanning mobility particle sizer (SMPS), and an electric low pressure impactor (ELPI). The aerosol mass concentration (C) was verified gravimetrically (mg/m(3)). The mass (M) of the collected particles was determined as M = (Mpost-Mpre), where Mpre and Mpost are masses of the filter before and after sampling (mg). The mass concentration was calculated as C = M/(Q*t), where Q is sampling flowrate (m(3)/min), and t is the sampling

  18. Evaluation of radio-protective effect of melatonin on whole body irradiation induced liver tissue damage.

    Science.gov (United States)

    Shirazi, Alireza; Mihandoost, Ehsan; Ghobadi, Ghazale; Mohseni, Mehran; Ghazi-Khansari, Mahmoud

    2013-01-01

    Ionizing radiation interacts with biological systems to induce excessive fluxes of free radicals that attack various cellular components. Melatonin has been shown to be a direct free radical scavenger and indirect antioxidant via its stimulatory actions on the antioxidant system.The aim of this study was to evaluate the antioxidant role of melatonin against radiation-induced oxidative injury to the rat liver after whole body irradiation. In this experimental study,thirty-two rats were divided into four groups. Group 1 was the control group, group 2 only received melatonin (30 mg/kg on the first day and 30 mg/kg on the following days), group 3 only received whole body gamma irradiation of 10 Gy, and group 4 received 30 mg/kg melatonin 30 minutes prior to radiation plus whole body irradiation of 10 Gy plus 30 mg/kg melatonin daily through intraperitoneal (IP) injection for three days after irradiation. Three days after irradiation, all rats were sacrificed and their livers were excised to measure the biochemical parameters malondialdehyde (MDA) and glutathione (GSH). Each data point represents mean ± standard error on the mean (SEM) of at least eight animals per group. A one-way analysis of variance (ANOVA) was performed to compare different groups, followed by Tukey's multiple comparison tests (p<0.05). The results demonstrated that whole body irradiation induced liver tissue damage by increasing MDA levels and decreasing GSH levels. Hepatic MDA levels in irradiated rats that were treated with melatonin (30 mg/kg) were significantly decreased, while GSH levels were significantly increased, when compared to either of the control groups or the melatonin only group. The data suggest that administration of melatonin before and after irradiation may reduce liver damage caused by gamma irradiation.

  19. Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

    DEFF Research Database (Denmark)

    Keller, Sune H; Holm, Søren; Hansen, Adam E

    2013-01-01

    Integrated whole-body PET/MRI tomographs have become available. PET/MR imaging has the potential to supplement, or even replace combined PET/CT imaging in selected clinical indications. However, this is true only if methodological pitfalls and image artifacts arising from novel MR-based attenuation...

  20. Metabolism and Whole-Body Fat Oxidation Following Post-Exercise Carbohydrate or Protein Intake

    DEFF Research Database (Denmark)

    Hall, Ulrika Andersson; Pettersson, Stefan; Edin, Fredrik

    2018-01-01

    : Protein supplementation immediately post-exercise did not affect the doubling in whole body fat oxidation seen during a subsequent exercise trial 2 hours later. Neither did it affect resting fat oxidation during the post-exercise period despite increased insulin levels and attenuated ketosis. Carbohydrate...

  1. Early and late allergic reaction in the nose assessed by whole body plethysmography

    NARCIS (Netherlands)

    deBruinWeller, MS; Weller, FR; Scholte, A; Rijssenbeek, LHM; vanderBaan, S; Bogaard, JM; deMonchy, JGR

    Physiological changes during late phase nasal responses after allergen challenge are difficult to establish and different criteria are used for the definition of a positive late phase nasal reaction. The objective of this study was to assess the value of whole body plethysmography in detecting

  2. Early and late allergic reaction in the nose assessed by whole body plethysmography

    NARCIS (Netherlands)

    de Bruin-Weller, M. S.; Weller, F. R.; Scholte, A.; Rijssenbeek, L. H.; van der Baan, S.; Bogaard, J. M.; de Monchy, J. G.

    1996-01-01

    Physiological changes during late phase nasal responses after allergen challenge are difficult to establish and different criteria are used for the definition of a positive late phase nasal reaction. The objective of this study was to assess the value of whole body plethysmography in detecting

  3. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  4. Experimental Quasi-Microwave Whole-Body Averaged SAR Estimation Method Using Cylindrical-External Field Scanning

    Science.gov (United States)

    Kawamura, Yoshifumi; Hikage, Takashi; Nojima, Toshio

    The aim of this study is to develop a new whole-body averaged specific absorption rate (SAR) estimation method based on the external-cylindrical field scanning technique. This technique is adopted with the goal of simplifying the dosimetry estimation of human phantoms that have different postures or sizes. An experimental scaled model system is constructed. In order to examine the validity of the proposed method for realistic human models, we discuss the pros and cons of measurements and numerical analyses based on the finite-difference time-domain (FDTD) method. We consider the anatomical European human phantoms and plane-wave in the 2GHz mobile phone frequency band. The measured whole-body averaged SAR results obtained by the proposed method are compared with the results of the FDTD analyses.

  5. The four-dimensional mouse whole-body phantoms and its application in medical imaging research

    International Nuclear Information System (INIS)

    Li Chongguo; Wu Dake

    2012-01-01

    Medical imaging simulation is a powerful tool for characterizing,evaluating,and optimizing medical imaging devices and techniques. A vital aspect of simulation is to have a realistic phantom or model of the subject's anatomy. Four-dimensional mouse whole-body phantoms provide realistic models of the mouse anatomy and physiology for imaging studies. When combined with accurate models for the imaging process,are capable of providing a wealth of realistic imaging data from subjects with various anatomies and motions (cardiac and respiratory) in health and disease. With this ability, the four-dimensional mouse whole-body phantoms have enormous potential to study the effects of anatomical, physiological and physical factors on medical and small animal imaging and to research new instrumentation, image acquisition strategies, image processing, reconstruction methods, image visualization and interpretation techniques. (authors)

  6. Carbon-14-ochratoxin A distribution in the Japanese quail (Coturnix coturnix japonica) monitored by whole body autoradiography

    International Nuclear Information System (INIS)

    Fuchs, R.; Appelgren, L.E.; Hagelberg, S.; Hult, K.

    1988-01-01

    Tissue distribution of the nephrotoxic mycotoxin ochratoxin A was characterized in laying Japanese quail by whole body autoradiography and scintillation counting using 14 C-labelled toxin. Periodically for 8 days after one intravenous injection of 14 microCi/bird, corresponding to 70 ng/g body weight, birds were killed, frozen, and sagittal sections of the whole body were placed on X-ray film. In general, the ochratoxin disappeared from the avian body rapidly. Specific retention of radioactivity was seen as a ring-like distribution in yolks and growing follicles. After sectioning, organs and intestinal contents were removed from carcasses in a frozen condition, homogenized, extracted, chromatographed, and the radioactivity in fractions was measured by scintillation spectroscopy. High concentrations of ochratoxin A were found in gastric intestinal contents, probably originating from toxin excreted in the bile

  7. Effects of whole-body cryotherapy on recovery after hamstring damaging exercise

    OpenAIRE

    Fonda, Borut; Šarabon, Nejc

    2013-01-01

    The purpose of this study was to examine the effects of whole-body cryotherapy (WBC) on biochemical, pain, and performance parameters during the 5-day recovery period after damaging exercise for hamstrings. Participants completed a bout of damaging exercise for the hamstring muscles on two separate occasions (control and experimental condition) separated by 10 weeks. During the control condition, subjects received no treatment after the damaging exercise. The experimental condition consisted ...

  8. Calibration of the A.E.E. Winfrith whole body monitor equipment with sodium-24 solution in a polythene man-phantom

    International Nuclear Information System (INIS)

    Peabody, C.O.; Speight, R.G.; Passant, F.H.

    1964-04-01

    Results are presented for the sensitivity of the existing Winfrith Whole Body Monitor equipment when used for measurement of sodium-24 activity in solution in a polythene man-phantom. The relationship is discussed between these results and those expected for the sodium-24 produced in a human body by accidental neutron irradiation. Estimates are made of the additional contribution of chlorine-38 activity at various times after whole body irradiation. (author)

  9. Value of whole body bone scan in the pre-operative assessment in carcinoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, P [Oerebro Regional Hospital (Sweden). Dept. of Oncology; Vikterloef, K J; Beckman, K W [Oerebro Regional Hospital (Sweden). Dept. of Radiation Physics; Rydman, H; Blom, O [Oerebro Regional Hospital (Sweden). Dept. of Diagnostic Radiology

    1979-01-01

    In 126 patients with primary breast cancer a patient moving whole-body bone scan was performed when they first presented. None of the patients in stage I had an evidence of skeletal metastases. Two patients (3%) of 62 in stage II and 4 patients (17%) in stage III had evidence of skeletal metastases. It appears that whole-body scanning is the most accurate, sensitive and convenient method of detecting osseous metastases and of staging breast cancer. This investigation should be carried out pre-operatively. Detection of early asymptomatic bony metastases will provide a better planning of treatment with rational approach.

  10. FDTD calculation of whole-body average SAR in adult and child models for frequencies from 30 MHz to 3 GHz

    International Nuclear Information System (INIS)

    Wang Jianqing; Fujiwara, Osamu; Kodera, Sachiko; Watanabe, Soichi

    2006-01-01

    Due to the difficulty of the specific absorption rate (SAR) measurement in an actual human body for electromagnetic radio-frequency (RF) exposure, in various compliance assessment procedures the incident electric field or power density is being used as a reference level, which should never yield a larger whole-body average SAR than the basic safety limit. The relationship between the reference level and the whole-body average SAR, however, was established mainly based on numerical calculations for highly simplified human modelling dozens of years ago. Its validity is being questioned by the latest calculation results. In verifying the validity of the reference level with respect to the basic SAR limit for RF exposure, it is essential to have a high accuracy of human modelling and numerical code. In this study, we made a detailed error analysis in the whole-body average SAR calculation for the finite-difference time-domain (FDTD) method in conjunction with the perfectly matched layer (PML) absorbing boundaries. We derived a basic rule for the PML employment based on a dielectric sphere and the Mie theory solution. We then attempted to clarify to what extent the whole-body average SAR may reach using an anatomically based Japanese adult model and a scaled child model. The results show that the whole-body average SAR under the ICNIRP reference level exceeds the basic safety limit nearly 30% for the child model both in the resonance frequency and 2 GHz band

  11. FDTD calculation of whole-body average SAR in adult and child models for frequencies from 30 MHz to 3 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Wang Jianqing [Graduate School of Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan); Fujiwara, Osamu [Graduate School of Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan); Kodera, Sachiko [Graduate School of Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan); Watanabe, Soichi [National Institute of Information and Communications Technology, Nukui-kitamachi, Koganei, Tokyo 184-8795 (Japan)

    2006-09-07

    Due to the difficulty of the specific absorption rate (SAR) measurement in an actual human body for electromagnetic radio-frequency (RF) exposure, in various compliance assessment procedures the incident electric field or power density is being used as a reference level, which should never yield a larger whole-body average SAR than the basic safety limit. The relationship between the reference level and the whole-body average SAR, however, was established mainly based on numerical calculations for highly simplified human modelling dozens of years ago. Its validity is being questioned by the latest calculation results. In verifying the validity of the reference level with respect to the basic SAR limit for RF exposure, it is essential to have a high accuracy of human modelling and numerical code. In this study, we made a detailed error analysis in the whole-body average SAR calculation for the finite-difference time-domain (FDTD) method in conjunction with the perfectly matched layer (PML) absorbing boundaries. We derived a basic rule for the PML employment based on a dielectric sphere and the Mie theory solution. We then attempted to clarify to what extent the whole-body average SAR may reach using an anatomically based Japanese adult model and a scaled child model. The results show that the whole-body average SAR under the ICNIRP reference level exceeds the basic safety limit nearly 30% for the child model both in the resonance frequency and 2 GHz band.

  12. Whole-body and pinhole bone scintigraphic manifestations of Reiter`s syndrome: distribution patterns and early and characteristic signs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-Hoon; Chung, Soo-Kyo; Park, Young-Ha; Lee, Sung-Yong; Sohn, Hyung-Sun [Department of Nuclear Medicine, Catholic University Hospitals, Seoul (Korea, Republic of); Bahk, Yong-Whee [Department of Radiology, Samsung Cheil Hospital, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    The characteristic whole-body and pinhole scintigraphic manifestations of osteo-enthesopathy and arthropathy in Reiter`s syndrome (RS) are described, with an emphasis on early diagnosis. We analysed 59 sets of whole-body and pinhole bone scintigrams of 59 patients with RS. The population comprised 47 men and 12 women with an age range from 15 to 53 years (mean=29.4). Bone scintigraphy was carried out 2-2.5 h after intravenous injection of technetium-99m hydroxydiphosphonate using a single-head gamma camera (Siemens Orbiter Model 6601) with a low-energy high-resolution and a 4-mm pinhole collimator for whole-body and pinhole scintigraphy, respectively. In total 262 lesions of osteo-enthesopathy and arthritis were detected on 59 whole-body scintigrams, an incidence of 4.4 lesions per patient. As anticipated, the lesional distribution was asymmetrical: 68% were in the lower limb skeleton and 32% in the axial and upper limb skeleton. Pinhole bone scintigraphy, applied selectively to one region of interest in each case, enabled us to accurately diagnose arthritis and osteo-enthesopathy. It was noteworthy that osteo-enthesopathy, alone or in combination with arthritis, occurred in 78.9%, and had a strong predilection for the foot bones, especially the calcaneus (25.6%). Pinhole scintigraphy detected enthesopathy in the absence of radiographic alteration in 14.1% of cases and portrayed characteristic signs of RS in 6.9%. Whole-body bone scintigraphy augmented with pinhole scintigraphy was found to be useful in order to panoramically display the systemic involvement pattern, to assess the characteristic bone and articular alterations and to detect early signs of RS. (orig.) With 10 figs., 3 tabs., 19 refs.

  13. Comparative evaluation of nose-only vs. whole-body inhalation exposures for rats

    International Nuclear Information System (INIS)

    Yeh, H.C.; Snipes, M.B.; Eidson, A.F.; Hobbs, C.H.

    1988-01-01

    Two types of rat exposure chambers, nose-only and whole-body chambers, were evaluated simultaneously for the temporal and spatial distribution of the same test aerosols within the chambers, both with and without animals present. Results indicated that both types of exposure chambers performed well, with coefficients of variation less than 10% for both temporal and spatial variations. (author)

  14. Whole-Body Vibration Does Not Seem to Affect Postural Control in Healthy Active Older Women

    Directory of Open Access Journals (Sweden)

    P. S. C. Gomes

    2018-01-01

    Full Text Available Objective. This study investigated the acute residual effects induced by different frequencies of whole-body vibration (WBV on postural control of elderly women. Design. Thirty physically active elderly women (67±5 years were randomly divided into three groups: two experimental groups (high WBV frequency: 45 Hz and 4 mm amplitude, n=10; low WBV frequency: 30 Hz and 4 mm amplitude, n=10 and one control group (n=10, with no treatment. The participants were first subjected to stabilometry tests and were then guided through three sets of isometric partial squats for 60 s while the WBV stimulation was applied. The control group was subjected to the same conditions but without the WBV stimulation. The participants were again subjected to body balance tests immediately following the end of the intervention period and again at 8, 16, and 24 min. To measure body sway control, three 60 s tests were performed at 10 s intervals for each of the following experimental conditions: (1 eyes opened and (2 eyes closed. The following variables were investigated: the average velocity of the displacement of the centre of pressure in the anterior-posterior and medial-lateral planes as well as in the elliptical area. Results. A 3 (condition × 5 (test two-way repeated-measures ANOVA did not identify significant differences in the stabilometric variables, regardless of group, time, or experimental condition. Conclusions. The effect of WBV, regardless of the stimulation frequency, did not have a significant effect immediately after or up to 24 minutes after vibration cessation, on the variables involved in the control of postural stability in physically active elderly women.

  15. Whole-body water flow stimulation to the lower limbs modulates excitability of primary motor cortical regions innervating the hands: a transcranial magnetic stimulation study.

    Directory of Open Access Journals (Sweden)

    Daisuke Sato

    Full Text Available Whole-body water immersion (WI has been reported to change sensorimotor integration. However, primary motor cortical excitability is not affected by low-intensity afferent input. Here we explored the effects of whole-body WI and water flow stimulation (WF on corticospinal excitability and intracortical circuits. Eight healthy subjects participated in this study. We measured the amplitude of motor-evoked potentials (MEPs produced by single transcranial magnetic stimulation (TMS pulses and examined conditioned MEP amplitudes by paired-pulse TMS. We evaluated short-interval intracortical inhibition (SICI and intracortical facilitation (ICF using the paired-TMS technique before and after 15-min intervention periods. Two interventions used were whole-body WI with water flow to the lower limbs (whole-body WF and whole-body WI without water flow to the lower limbs (whole-body WI. The experimental sequence included a baseline TMS assessment (T0, intervention for 15 min, a second TMS assessment immediately after intervention (T1, a 10 min resting period, a third TMS assessment (T2, a 10 min resting period, a fourth TMS assessment (T3, a 10 min resting period, and the final TMS assessment (T4. SICI and ICF were evaluated using a conditioning stimulus of 90% active motor threshold and a test stimulus adjusted to produce MEPs of approximately 1-1.2 mV, and were tested at intrastimulus intervals of 3 and 10 ms, respectively. Whole-body WF significantly increased MEP amplitude by single-pulse TMS and led to a decrease in SICI in the contralateral motor cortex at T1, T2 and T3. Whole-body WF also induced increased corticospinal excitability and decreased SICI. In contrast, whole-body WI did not change corticospinal excitability or intracortical circuits.

  16. Whole-body water flow stimulation to the lower limbs modulates excitability of primary motor cortical regions innervating the hands: a transcranial magnetic stimulation study.

    Science.gov (United States)

    Sato, Daisuke; Yamashiro, Koya; Onishi, Hideaki; Baba, Yasuhiro; Nakazawa, Sho; Shimoyama, Yoshimitsu; Maruyama, Atsuo

    2014-01-01

    Whole-body water immersion (WI) has been reported to change sensorimotor integration. However, primary motor cortical excitability is not affected by low-intensity afferent input. Here we explored the effects of whole-body WI and water flow stimulation (WF) on corticospinal excitability and intracortical circuits. Eight healthy subjects participated in this study. We measured the amplitude of motor-evoked potentials (MEPs) produced by single transcranial magnetic stimulation (TMS) pulses and examined conditioned MEP amplitudes by paired-pulse TMS. We evaluated short-interval intracortical inhibition (SICI) and intracortical facilitation (ICF) using the paired-TMS technique before and after 15-min intervention periods. Two interventions used were whole-body WI with water flow to the lower limbs (whole-body WF) and whole-body WI without water flow to the lower limbs (whole-body WI). The experimental sequence included a baseline TMS assessment (T0), intervention for 15 min, a second TMS assessment immediately after intervention (T1), a 10 min resting period, a third TMS assessment (T2), a 10 min resting period, a fourth TMS assessment (T3), a 10 min resting period, and the final TMS assessment (T4). SICI and ICF were evaluated using a conditioning stimulus of 90% active motor threshold and a test stimulus adjusted to produce MEPs of approximately 1-1.2 mV, and were tested at intrastimulus intervals of 3 and 10 ms, respectively. Whole-body WF significantly increased MEP amplitude by single-pulse TMS and led to a decrease in SICI in the contralateral motor cortex at T1, T2 and T3. Whole-body WF also induced increased corticospinal excitability and decreased SICI. In contrast, whole-body WI did not change corticospinal excitability or intracortical circuits.

  17. Effects of chronic whole-body gamma irradiation on cell mediated immunity

    International Nuclear Information System (INIS)

    Shifrine, M.; Taylor, N.J.; Wilson, F.D.; DeRock, E.W.; Wiger, N.

    1979-01-01

    The whole blood lymphocyte stimulation test has been used to estimate the effects of chronic, whole-body, gamma irradiation in the dog. At lower dose levels, 0.07 and 0.33 R/day to cumulative dose of about 50 and 250 R, there was no change in cell mediated immunity. Dogs at high dose levels were affected. Dogs which succumbed to aplastic anemia at high doses had reduced immunological responses. Dogs which survived these high doses showed a temporary depression. When aplastic anemia was initially noted, there was a differential response to PHA and Con-A stimulation. The response to the former mitogen was profoundly reduced, but Con-A stimulated cells were unaffected, indicative of the development of radioresistant cell lines. As the dogs progressed toward aplastic anemia, all T lympocytes were negatively affected

  18. Whole body bone scintigram with sup(99m)Tc-phosphate compounds

    International Nuclear Information System (INIS)

    Oyamada, Hiyoshimaru; Orii, Hirotake; Tabei, Toshio; Ishibashi, Hiroyoshi.

    1975-01-01

    Among the compounds of four different types, which are sup(99m)Tc-polyphosphate suppled by A Company, sup(99m)Tc-pyrophosphate by B Company, and sup(99m)Tc-pyrophosphate of electrolysis method and sup(99m)Tc-diphosphonate by C Company, sup(99m)Tc-diphosphonate showed the most favorable result with a constantly good scintigram quality. The remaining three compounds were found also favorable for clinical application. Besides these are undesirable accumulations, rather low energy of sup(99m)Tc-causes different pictures upon the anterior and the posterior views, and previously irradiated area shows a decreased uptake of these compounds. The usefulness of whole body scintigrams in the detection of metastatic bone tumors was also discussed. There was a definite superiority with this technique over the conventional X-ray study. Especially, in thoracic vertebrae, pelvic bone, and ribs, far many diseased areas were detected on the scintigrams than the areas which the physicians noticed or suspected the metastases. As a conclusion, although there are some problems on the scintigrams, it can be said that sup(99m)Tc-phosphate compounds are very useful in detection of metastatic bone tumors, especially with the help of whole body scanner. (JPN)

  19. Whole-body vibration improves cognitive functions of an adult with ADHD.

    Science.gov (United States)

    Fuermaier, Anselm B M; Tucha, Lara; Koerts, Janneke; van den Bos, Meinris; Regterschot, G Ruben H; Zeinstra, Edzard B; van Heuvelen, Marieke J G; van der Zee, Eddy A; Lange, Klaus W; Tucha, Oliver

    2014-09-01

    Adult attention deficit hyperactivity disorder (ADHD) is associated with a variety of cognitive impairments, which were shown to affect academic achievement and quality of life. Current treatment strategies, such as stimulant drug treatment, were demonstrated to effectively improve cognitive functions of patients with ADHD. However, most treatment strategies are associated with a number of disadvantages in a considerable proportion of patients, such as unsatisfactory effects, adverse clinical side effects or high financial costs. In order to address limitations of current treatment strategies, whole-body vibration (WBV) might represent a novel approach to treat cognitive dysfunctions of patients with ADHD. WBV refers to the exposure of the whole body of an individual to vibration and was found to affect physiology and cognition. In the present study, WBV was applied on 10 consecutive days to an adult diagnosed with ADHD. Neuropsychological assessments were performed repeatedly at three different times, i.e., the day before the start of the treatment, on the day following completion of treatment and 14 days after the treatment have been completed (follow-up). An improved neuropsychological test performance following WBV treatment points to the high clinical value of WBV in treating patients with neuropsychological impairments such as ADHD.

  20. Body Composition, Lipid Profile, Adipokine Concentration, and Antioxidant Capacity Changes during Interventions to Treat Overweight with Exercise Programme and Whole-Body Cryostimulation

    Directory of Open Access Journals (Sweden)

    Anna Lubkowska

    2015-01-01

    Full Text Available The aim of this study was to determine the effect of six-month-long physical exercise programme with a two-time exposure to whole-body cryostimulation (WBC in 20 sessions on antioxidant enzyme activities, lipid profile, and body composition changes in obese people (30 adult subjects; BMI = 30.39 ± 4.31 kg/m2. Blood samples were taken before the programme, one month following the exercise programme, before and after the first WBC treatment, six months following the exercise programme, after the second WBC treatment, and finally one month after the intervention. Six months of moderate aerobic activity combined with WBC did not change body mass or fat and lean body mass percentages, or circulating adiponectin, leptin, and resistin concentrations. In response to intervention a significant decrease in the level of low-density lipoprotein and triglycerides was observed, with a slight increase in high-density lipoprotein concentration. The nature of changes in the activity of respective antioxidant enzymes was not identical. After one month of increased physical activity, a significant decrease in superoxide dismutase, catalase, and glutathione reductase activities was observed (13%, 8%, and 70%, resp.. The SOD activity increased significantly after successive whole-body cryostimulation sessions. As regards catalase, a significant progressive decrease in its activity was observed.