WorldWideScience

Sample records for acute whole-body proton

  1. Whole body proton irradiation causes acute damage to bone marrow hematopoietic progenitor and stem cells in mice.

    Science.gov (United States)

    Chang, Jianhui; Wang, Yingying; Pathak, Rupak; Sridharan, Vijayalakshmi; Jones, Tamako; Mao, Xiao Wen; Nelson, Gregory; Boerma, Marjan; Hauer-Jensen, Martin; Zhou, Daohong; Shao, Lijian

    2017-12-01

    Exposure to proton irradiation during missions in deep space can lead to bone marrow injury. The acute effects of proton irradiation on hematopoietic stem and progenitor cells remain undefined and thus were investigated. We exposed male C57BL/6 mice to 0.5 and 1.0 Gy proton total body irradiation (proton-TBI, 150 MeV) and examined changes in peripheral blood cells and bone marrow (BM) progenitors and LSK cells 2 weeks after exposure. 1.0 Gy proton-TBI significantly reduced the numbers of peripheral blood cells compared to 0.5 Gy proton-TBI and unirradiated animals, while the numbers of peripheral blood cell counts were comparable between 0.5 Gy proton-TBI and unirradiated mice. The frequencies and numbers of LSK cells and CMPs in BM of 0.5 and 1.0 Gy irradiated mice were decreased in comparison to those of normal controls. LSK cells and CMPs and their progeny exhibited a radiation-induced impairment in clonogenic function. Exposure to 1.0 Gy increased cellular apoptosis but not the production of reactive oxygen species (ROS) in CMPs two weeks after irradiation. LSK cells from irradiated mice exhibited an increase in ROS production and apoptosis. Exposure to proton-TBI can induce acute damage to BM progenitors and LSK cells.

  2. Gene Expression Changes in Mouse Intestinal Tissue Following Whole-Body Proton or Gamma-Irradiation

    Science.gov (United States)

    Purgason, Ashley; Zhang, Ye; Mangala, Lingegowda; Nie, Ying; Gridley, Daila; Hamilton, Stanley R.; Seidel, Derek V.; Wu, Honglu

    2014-01-01

    Crew members face potential consequences following exposure to the space radiation environment including acute radiation syndrome and cancer. The space radiation environment is ample with protons, and numerous studies have been devoted to the understanding of the health consequences of proton exposures. In this project, C57BL/6 mice underwent whole-body exposure to 250 MeV of protons at doses of 0, 0.1, 0.5, 2 and 6 Gy and the gastrointestinal (GI) tract of each animal was dissected four hours post-irradiation. Standard H&E staining methods to screen for morphologic changes in the tissue showed an increase in apoptotic lesions for even the lowest dose of 0.1 Gy, and the percentage of apoptotic cells increased with increasing dose. Results of gene expression changes showed consistent up- or down- regulation, up to 10 fold, of a number of genes across exposure doses that may play a role in proton-induced oxidative stress including Gpx2. A separate study in C57BL/6 mice using the same four hour time point but whole-body gamma-irradiation showed damage to the small intestine with lesions appearing at the smallest dose of 0.05 Gy and increasing with increasing absorbed dose. Expressions of genes associated with oxidative stress processes were analyzed at four hours and twenty-four hours after exposure to gamma rays. We saw a much greater number of genes with significant up- or down-regulation twenty-four hours post-exposure as compared to the four hour time point. At both four hours and twenty-four hours post-exposure, Duox1 and Mpo underwent up-regulation for the highest dose of 6 Gy. Both protons and gamma rays lead to significant variation in gene expressions and these changes may provide insight into the mechanism of injury seen in the GI tract following radiation exposure. We have also completed experiments using a BALB/c mouse model undergoing whole-body exposure to protons. Doses of 0, 0.1, 1 and 2 Gy were used and results will be compared to the work mentioned

  3. Acute whole-body vibration increases reciprocal inhibition.

    Science.gov (United States)

    Ritzmann, Ramona; Krause, Anne; Freyler, Kathrin; Gollhofer, Albert

    2018-06-26

    Based on previous evidence that whole-body vibration (WBV) affects pathways involved in disynaptic reciprocal inhibition (DRI), the present hypothesis-driven experiment aimed to assess the acute effects of WBV on DRI and co-contraction. DRI from ankle dorsiflexors to plantar flexors was investigated during submaximal dorsiflexion before and after 1 min of WBV. With electromyography, musculus soleus (SOL) H-reflex depression following a conditioning stimulation of the peroneal nerve (1.1x motor threshold for the musculus tibialis anterior, TA) was assessed and co-contraction was calculated. After WBV, DRI was significantly increased (+4%, p < 0.05). SOL (-13%, p < 0.05) and TA (-6%, p < 0.05) activities were significantly reduced; co-contraction tended to be diminished (-8%, p = 0.05). Dorsiflexion torque remained unchanged. After WBV, DRI increased during submaximal isometric contraction in healthy subjects. The simultaneous SOL relaxation and TA contraction indicate that a more economic movement execution is of functional significance for WBV application in clinical and athletic treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Acute volume expansion preserves orthostatic tolerance during whole-body heat stress in humans.

    Science.gov (United States)

    Keller, David M; Low, David A; Wingo, Jonathan E; Brothers, R Matthew; Hastings, Jeff; Davis, Scott L; Crandall, Craig G

    2009-03-01

    Whole-body heat stress reduces orthostatic tolerance via a yet to be identified mechanism(s). The reduction in central blood volume that accompanies heat stress may contribute to this phenomenon. The purpose of this study was to test the hypothesis that acute volume expansion prior to the application of an orthostatic challenge attenuates heat stress-induced reductions in orthostatic tolerance. In seven normotensive subjects (age, 40 +/- 10 years: mean +/- S.D.), orthostatic tolerance was assessed using graded lower-body negative pressure (LBNP) until the onset of symptoms associated with ensuing syncope. Orthostatic tolerance (expressed in cumulative stress index units, CSI) was determined on each of 3 days, with each day having a unique experimental condition: normothermia, whole-body heating, and whole-body heating + acute volume expansion. For the whole-body heating + acute volume expansion experimental day, dextran 40 was rapidly infused prior to LBNP sufficient to return central venous pressure to pre-heat stress values. Whole-body heat stress alone reduced orthostatic tolerance by approximately 80% compared to normothermia (938 +/- 152 versus 182 +/- 57 CSI; mean +/- S.E.M., P body heating completely ameliorated the heat stress-induced reduction in orthostatic tolerance (1110 +/- 69 CSI, P stress results in many cardiovascular and neural responses that directionally challenge blood pressure regulation, reduced central blood volume appears to be an underlying mechanism responsible for impaired orthostatic tolerance in the heat-stressed human.

  5. Acute effect of whole body vibration on postural control in congenitally blind subjects: a preliminary evidence.

    Science.gov (United States)

    di Cagno, Alessandra; Giombini, Arrigo; Iuliano, Enzo; Moffa, Stefano; Caliandro, Tiziana; Parisi, Attilio; Borrione, Paolo; Calcagno, Giuseppe; Fiorilli, Giovanni

    2017-07-11

    The purpose of this study was to investigate the acute effects of whole body vibration at optimal frequency, on postural control in blind subjects. Twenty-four participants, 12 congenital blind males (Experimental Group), and 12 non-disabled males with no visual impairment (Control Groups) were recruited. The area of the ellipse and the total distance of the center of pressure displacements, as postural control parameters, were evaluated at baseline (T0), immediately after the vibration (T1), after 10 min (T10) and after 20 min (T20). Whole body vibration protocol consisted into 5 sets of 1 min for each vibration, with 1 min rest between each set on a vibrating platform. The total distance of center of pressure showed a significant difference (p < 0.05) amongst groups, while the area remained constant. No significant differences were detected among times of assessments, or in the interaction group × time. No impairments in static balance were found after an acute bout of whole body vibration at optimal frequency in blind subjects and, consequently, whole body vibration may be considered as a safe application in individuals who are blind.

  6. Whole body perfusion in patients undergoing frozen elephant trunk for type A acute aortic dissections.

    Science.gov (United States)

    Cappabianca, Giangiuseppe; Roscitano, Claudio; Bichi, Samuele; Cricco, Antonio; Parrinello, Matteo; Beghi, Cesare; Albano, Giovanni; Esposito, Giampiero

    2017-03-01

    The Frozen Elephant Trunk (FET) can be adopted in selected type A acute aortic dissections (TAAAD). During FET, a prolonged distal circulatory arrest exposes the spine and visceral organs to potential ischemic injuries. Antegrade distal aortic perfusion (ADAP) could minimize this risk: we describe the technical aspects of the simultaneous use of antegrade cerebral perfusion (ACP) and ADAP achieving a "Whole Body Perfusion" (WBP) during FET.

  7. A Comparison of Molecular and Histopathological Changes in Mouse Intestinal Tissue Following Whole-Body Proton- or Gamma-Irradiation

    Science.gov (United States)

    Purgason, Ashley; Mangala, Lingegowda; Zhang, Ye; Hamilton, Stanley; Wu, Honglu

    2010-01-01

    There are many consequences following exposure to the space radiation environment which can adversely affect the health of a crew member. Acute radiation syndrome (ARS) involving nausea and vomiting, damage to radio-sensitive tissue such as the blood forming organs and gastrointestinal tract, and cancer are some of these negative effects. The space radiation environment is ample with protons and contains gamma rays as well. Little knowledge exists to this point, however, regarding the effects of protons on mammalian systems; conversely several studies have been performed observing the effects of gamma rays on different animal models. For the research presented here, we wish to compare our previous work looking at whole-body exposure to protons using a mouse model to our studies of mice experiencing whole-body exposure to gamma rays as part of the radio-adaptive response. Radio-adaptation is a well-documented phenomenon in which cells exposed to a priming low dose of radiation prior to a higher dose display a reduction in endpoints like chromosomal aberrations, cell death, micronucleus formation, and more when compared to their counterparts receiving high dose-irradiation only. Our group has recently completed a radio-adaptive experiment with C57BL/6 mice. For both this study and the preceding proton research, the gastrointestinal tract of each animal was dissected four hours post-irradiation and the isolated small intestinal tissue was fixed in formalin for histopathological examination or snap-frozen in liquid nitrogen for RNA isolation. Histopathologic observation of the tissue using standard H&E staining methods to screen for morphologic changes showed an increase in apoptotic lesions for even the lowest doses of 0.1 Gy of protons and 0.05 Gy of gamma rays, and the percentage of apoptotic cells increased with increasing dose. A smaller percentage of crypts showed 3 or more apoptotic lesions in animals that received 6 Gy of gamma-irradiation compared to mice

  8. Acute effects of whole body gamma irradiation on exocrine pancreatic secretion in the pig

    International Nuclear Information System (INIS)

    Monti, P.; Scanff, P.; Joubert, C.; Vergnet, M.; Grison, S.; Griffiths, N.

    2004-01-01

    Reports on radiation damage to the pancreas deal essentially with long-term morphological changes with few data on pancreatic exocrine function. The aim of this work was to study the acute effects of whole body irradiation on volume and enzyme activities in the pancreatic juice. A whole body gamma irradiation (6 Gy) was investigated in pigs with continuous sampling of pancreatic juice before and after exposure via an indwelling catheter in the pancreatic duct. For each sample collected, total protein concentration and enzyme activities of trypsin, chymotrypsin, elastase, lipase and amylase were determined. Pancreatic juice volume was monitored during all periods of collection. The volume of pancreatic juice secreted daily decreased one day after irradiation and remained lower than the control values over the experimental period. Total proteins secreted in the pancreatic juice and total activities of pancreatic enzymes were reduced similarly. On the other hand, only specific activities of elastase and lipase were affected by irradiation. Whole body gamma irradiation resulted in a rapid and marked decrease of exocrine pancreatic secretion, in terms of volume as well as secreted enzymes. This may contribute in part to the intestinal manifestations of the acute and/or late radiation syndrome. (author)

  9. Acute interleukin-6 administration does not impair muscle glucose uptake or whole-body glucose disposal in healthy humans

    DEFF Research Database (Denmark)

    Steensberg, Adam; Fischer, Christian P; Sacchetti, Massimo

    2003-01-01

    adrenaline (epinephrine). IL-6 infusion, irrespective of dose, did not result in any changes to endogenous glucose production, whole-body glucose disposal or leg- glucose uptake. These data demonstrate that acute IL-6 administration does not impair whole-body glucose disposal, net leg-glucose uptake......The cytokine interleukin (IL)-6 has recently been linked with type 2 diabetes mellitus and has been suggested to affect glucose metabolism. To determine whether acute IL-6 administration affects whole-body glucose kinetics or muscle glucose uptake, 18 healthy young men were assigned to one of three...... the cessation of infusion (recovery) to determine endogenous glucose production and whole-body glucose disposal. Infusion with HiIL-6 and LoIL-6 resulted in a marked (P

  10. Acute Whole Body Vibration Decreases the Glucose Levels in Elderly Diabetic Women

    Directory of Open Access Journals (Sweden)

    Maíra Florentino Pessoa

    2018-01-01

    Full Text Available Type II diabetes (TIIDM is characterized by high levels of blood glucose followed by excessive insulin release so that the target cells become less sensitive, developing insulin resistance and maintaining hyperglycemic levels. Physical activity is the strongest element to prevent and to manage the TIIDM, and the majority of patients do not remain in regularly active levels, because the premature fatigue in these patients decreases the adherence to the training. Contrastingly, the whole body vibration (WBV training may improve the glucose metabolism in diabetic patients, reducing the peripheral blood sugar, decreasing the physical discomfort and perceived exertion. Therefore, the purpose of the study was to determine the effect of an acute WBV session as therapy to promote fasting decreases in insulin levels in peripheral blood in TIIDM when compared to healthy elderly. For this, fifteen healthy elderly women and fourteen diabetic elderly women, all sedentary, were allocated in diabetic or control groups, and we made an acute whole body session composed of 10 bouts lasting 2 minutes each one, separated by a 30-second rest period. The WBV was executed in a triaxial platform MY3 Power Plate® at 35 hertz and has been chosen a peak-to-peak displacement of 4 millimeters. After the protocol, both groups decreased the glycemic levels and increased lactate production in relation to the basal levels and when compared diabetic and control, where the most important results have been shown in diabetic women. This study revealed that WBV training in TIIDM has had significant beneficial effects on the control of glucose levels, still in an acute session. So that, the complete training probably will show better results about glycemic control and this finding could be especially important when prescribing exercise for elderly who are unable or unwilling to use traditional loads or who show poor exercise compliance.

  11. The modes of death in mammals exposed to whole body radiation (acute radiation syndromes)

    International Nuclear Information System (INIS)

    Santos, O.R. dos.

    1990-07-01

    When an animal is exposed to a sufficient amount of radiation, there will be changes in many organs of the body, and as a result of either the effects in one particular organ or the interaction of effects in several organs, the animal as a whole will show characteristic syndromes. Some syndromes result inevitably in death. Others may or may not be lethal, depending on the extent of the tissue damage. The time of appearance of the syndromes, their duration, and the survival of the organism depend on many factors. Whole body acute doses of radiation produce the same spectrum of Central Nervous System (CNS), Gastrointestinal (GI) and Bone Marrow (BM) injury in man as was described for animals. Damage to the skin, ovary and testis are an integral and important part of the symptoms. (author) [pt

  12. Professional Soccer Player Neuromuscular Responses and Perceptions to Acute Whole Body Vibration Differ from Amateur Counterparts

    Directory of Open Access Journals (Sweden)

    Ross Cloak, Andrew Lane, Matthew Wyon

    2016-03-01

    Full Text Available Acute whole body vibration (WBV is an increasingly popular training technique amongst athletes immediately prior to performance and during scheduled breaks in play. Despite its growing popularity, evidence to demonstrate its effectiveness on acute neuromuscular responses is unclear, and suggestions that athlete ability impacts effectiveness warrant further investigation. The purpose of this study was to compare the neuromuscular effects of acute WBV and perceptions of whether WBV is an effective intervention between amateur and professional soccer players. Participants were 44 male soccer players (22 professional and 22 amateur; age: 23.1 ± 3.7 years, body mass: 75.6 ± 8.8 kg and height: 1.77 ± 0.05 m. Participants in each group were randomly assigned to either an intervention of 3 x 60 s of WBV at 40 Hz (8mm peak-to-peak displacement or control group. Peak knee isometric force, muscle activation and post activation potentiation (PAP of the knee extensors along with self-report questionnaire of the perceived benefits of using the intervention were collected. A three-way ANOVA with repeated measures revealed professional players demonstrated a significant 10.6% increase (p < 0.01, Partial Eta2 = 0.22 in peak knee isometric force following acute WBV with no significant differences among amateur players. A significant difference (p < 0.01, Partial Eta2 = 0.16 in PAP amongst professional players following acute WBVT was also reported. No significant differences amongst amateur players were reported across measurements. Results also indicated professional players reported significantly stronger positive beliefs in the effectiveness of the WBV intervention (p < 0.01, Partial Eta2 = 0.27 compared to amateur players. Acute WBV elicited a positive neuromuscular response amongst professional players identified by PAP and improvements in knee isometric peak force as well as perceived benefits of the intervention, benefits not found among amateur players.

  13. Acute Whole-Body Vibration does not Facilitate Peak Torque and Stretch Reflex in Healthy Adults

    Directory of Open Access Journals (Sweden)

    Ella W. Yeung

    2013-03-01

    Full Text Available The acute effect of whole-body vibration (WBV training may enhance muscular performance via neural potentiation of the stretch reflex. The purpose of this study was to investigate if acute WBV exposure affects the stretch induced knee jerk reflex [onset latency and electromechanical delay (EMD] and the isokinetic knee extensor peak torque performance. Twenty-two subjects were randomly assigned to the intervention or control group. The intervention group received WBV in a semi-squat position at 30° knee flexion with an amplitude of 0.69 mm, frequency of 45 Hz, and peak acceleration of 27.6 m/s2 for 3 minutes. The control group underwent the same semii-squatting position statically without exposure of WBV. Two-way mixed repeated measures analysis of variance revealed no significant group effects differences on reflex latency of rectus femoris (RF and vastus lateralis (VL; p = 0.934 and 0.935, respectively EMD of RF and VL (p = 0.474 and 0.551, respectively and peak torque production (p = 0.483 measured before and after the WBV. The results of this study indicate that a single session of WBV exposure has no potentiation effect on the stretch induced reflex and peak torque performance in healthy young adults.

  14. Acute whole-body cooling for exercise-induced hyperthermia: a systematic review.

    Science.gov (United States)

    McDermott, Brendon P; Casa, Douglas J; Ganio, Matthew S; Lopez, Rebecca M; Yeargin, Susan W; Armstrong, Lawrence E; Maresh, Carl M

    2009-01-01

    To assess existing original research addressing the efficiency of whole-body cooling modalities in the treatment of exertional hyperthermia. During April 2007, we searched MEDLINE, EMBASE, Scopus, SportDiscus, CINAHL, and Cochrane Reviews databases as well as ProQuest for theses and dissertations to identify research studies evaluating whole-body cooling treatments without limits. Key words were cooling, cryotherapy, water immersion, cold-water immersion, ice-water immersion, icing, fanning, bath, baths, cooling modality, heat illness, heat illnesses, exertional heatstroke, exertional heat stroke, heat exhaustion, hyperthermia, hyperthermic, hyperpyrexia, exercise, exertion, running, football, military, runners, marathoner, physical activity, marathoning, soccer, and tennis. Two independent reviewers graded each study on the Physiotherapy Evidence Database (PEDro) scale. Seven of 89 research articles met all inclusion criteria and a minimum score of 4 out of 10 on the PEDro scale. After an extensive and critical review of the available research on whole-body cooling for the treatment of exertional hyperthermia, we concluded that ice-water immersion provides the most efficient cooling. Further research comparing whole-body cooling modalities is needed to identify other acceptable means. When ice-water immersion is not possible, continual dousing with water combined with fanning the patient is an alternative method until more advanced cooling means can be used. Until future investigators identify other acceptable whole-body cooling modalities for exercise-induced hyperthermia, ice-water immersion and cold-water immersion are the methods proven to have the fastest cooling rates.

  15. Acute effects of unilateral whole body vibration training on single leg vertical jump height and symmetry in healthy men.

    Science.gov (United States)

    Shin, Seungho; Lee, Kyeongjin; Song, Changho

    2015-12-01

    [Purpose] The aim of the present study was to investigate the acute effects of unilateral whole body vibration training on height and symmetry of the single leg vertical jump in healthy men. [Subjects] Thirty males with no history of lower limb dysfunction participated in this study. [Methods] The participants were randomly allocated to one of three groups: the unilateral vibratory stimulation group (n=10), bilateral vibratory stimulation group (n=10), and, no vibratory stimulation group (n=10). The subjects in the unilateral and bilateral stimulation groups participated in one session of whole body vibration training at 26 Hz for 3 min. The no vibratory stimulation group subjects underwent the same training for 3 min without whole body vibration. All participants performed the single leg vertical jump for each lower limb, to account for the strong and weak sides. The single leg vertical jump height and symmetry were measured before and after the intervention. [Results] The single leg vertical jump height of the weak lower limb significantly improved in the unilateral vibratory stimulation group, but not in the other groups. The single leg vertical jump height of the strong lower limb significantly improved in the bilateral vibratory stimulation group, but not in the other groups. The single leg vertical jump symmetry significantly improved in the unilateral vibratory stimulation group, but not in the other groups. [Conclusion] Therefore, the present study found that the effects of whole body vibration training were different depending on the type of application. To improve the single leg vertical jump height in the weak lower limbs as well as limb symmetry, unilateral vibratory stimulation might be more desirable.

  16. Whole-body cortisol response of zebrafish to acute net handling stress

    Science.gov (United States)

    Ramsay, J.M.; Feist, G.W.; Varga, Z.M.; Westerfield, M.; Kent, M.L.; Schreck, C.B.

    2009-01-01

    Zebrafish, Danio rerio, are frequently handled during husbandry and experimental procedures in the laboratory, yet little is known about the physiological responses to such stressors. We measured the whole-body cortisol levels of adult zebrafish subjected to net stress and air exposure at intervals over a 24 h period; cortisol recovered to near control levels by about 1 h post-net-stress (PNS). We then measured cortisol at frequent intervals over a 1 h period. Cortisol levels were more than 2-fold higher in net stressed fish at 3 min PNS and continued to increase peaking at 15 min PNS, when cortisol levels were 6-fold greater than the control cortisol. Mean cortisol declined from 15 to 60 min PNS, and at 60 min, net-stressed cortisol was similar to control cortisol. Because the age of fish differed between studies, we examined resting cortisol levels of fish of different ages (3, 7, 13, and 19 months). The resting cortisol values among tanks with the same age fish differed significantly but there was no clear effect of age. Our study is the first to report the response and recovery of cortisol after net handling for laboratory-reared zebrafish. ?? 2009 Elsevier B.V.

  17. Study of food intake dynamics in rats following acute whole-body irradiation with X rays

    International Nuclear Information System (INIS)

    Smajda, B.; Ahlers, I.; Datelinka, I.

    1987-01-01

    The effects were studied of whole-body X-irradiation with sublethal (2.39 Gy) and medium lethal (5.74 Gy) doses on food intake by rats. The lower dose caused a temporary decrease in food intake, with a minimum of 63.3% of the control level on the 2nd day after irradiation. The decrease was statistically significant up to the 4th day after irradiation. No substantial changes were observed in the parameters of the circadian rhythm in food intake with the maximum on the 3rd day after irradiation, with only 8% of the initial value. The food intake was reduced until the 9th day after irradiation. The daily thythm of food intake was strongly disturbed during the first three days after irradiation, then restoring gradually and on the 9th day showing the original phasing and shape. The results obtained were in agreement with the assumed neural regulation mechanism of food intake and its circadian rhythm in the rat. (author). 5 figs., 12 refs

  18. Acute effects of whole-body vibration on the motor function of patients with stroke: a randomized clinical trial.

    Science.gov (United States)

    Silva, Adriana Teresa; Dias, Miqueline Pivoto Faria; Calixto, Ruanito; Carone, Antonio Luis; Martinez, Beatriz Bertolaccini; Silva, Andreia Maria; Honorato, Donizeti Cesar

    2014-04-01

    The aim of this study was to investigate the acute effects of whole-body vibration on the motor function of patients with stroke. The present investigation was a randomized clinical trial studying 43 individuals with hemiparesis after stroke, with 33 subjects allocated to the intervention group and 10 subjects allocated to the control group. The intervention group was subjected to one session of vibration therapy (frequency of 50 Hz and amplitude of 2 mm) comprising four 1-min series with 1-min rest intervals between series in three body positions: bipedal stances with the knees flexed to 30 degrees and 90 degrees and a unipedal stance on the paretic limb. The analytical tests were as follows: simultaneous electromyography of the affected and unaffected tibialis anterior and rectus femoris muscles bilaterally in voluntary isometric contraction; the Six-Minute Walk Test; the Stair-Climb Test; and the Timed Get-Up-and-Go Test. The data were analyzed by independent and paired t tests and by analysis of covariance. There was no evidence of effects on the group and time interaction relative to variables affected side rectus femoris, unaffected side rectus femoris, affected side tibialis anterior, unaffected side tibialis anterior, and the Stair-Climb Test (P > 0.05). There was evidence of effects on the group interaction relative to variables Six-Minute Walk Test and Timed Get-Up-and-Go Test (P < 0.05). Whole-body vibration contributed little to improve the functional levels of stroke patients.

  19. High-Intensity Interval Exercises' Acute Impact on Heart Rate Variability: Comparison Between Whole-Body and Cycle Ergometer Protocols.

    Science.gov (United States)

    Schaun, Gustavo Z; Del Vecchio, Fabrício B

    2018-01-01

    Schaun, GZ and Del Vecchio, FB. High-intensity interval exercises' acute impact on heart rate variability: comparison between whole-body and cycle ergometer protocols. J Strength Cond Res 32(1): 223-229, 2018-Study aimed to compare the effects of 2 high-intensity interval training (HIIT) protocols on heart rate variability. Twelve young adult males (23.3 ± 3.9 years, 177.8 ± 7.4 cm, 76.9 ± 12.9 kg) volunteered to participate. In a randomized cross-over design, subjects performed 2 HIIT protocols, 1 on a cycle ergometer (Tabata protocol [TBT]; eight 20-second bouts at 170% Pmax interspersed by 10-second rest) and another with whole-body calisthenic exercises (McRae protocol; eight 20-second all-out intervals interspersed by 10-second rest). Heart rate variability outcomes in the time, frequency, and nonlinear domains were assessed on 3 moments: (a) presession; (b) immediately postsession; and (c) 24 hours postsession. Results revealed that RRmean, Ln rMSSD, Ln high frequency (HF), and Ln low frequency (LF) were significantly reduced immediately postsession (p ≤ 0.001) and returned to baseline 24 h after both protocols. In addition, LF/HF ratio was reduced 24 h postsession (p ≤ 0.01) and SD2 was significantly lower immediately postsession only in TBT. Our main finding was that responses from heart rate autonomic control were similar in both protocols, despite different modes of exercise performed. Specifically, exercises resulted in a high parasympathetic inhibition immediately after session with subsequent recovery within 1 day. These results suggest that subjects were already recovered the day after and can help coaches to better program training sessions with such protocols.

  20. Acute Cutaneous Microvascular Flow Responses to Whole-Body Tilting in Humans

    Science.gov (United States)

    Breit, Gregory A.; Watenpaugh, Donald E.; Ballard, Richard E.; Hargens, Alan R.

    1993-01-01

    The transition from upright to head-down tilt (HDT) posture in humans increases blood pressure superior to the heart and decreases pressure inferior to the heart. Consequently, above heart level, myogenic arteriolar tone probably increases with HDT, in opposition to the withdrawal of baroreceptor-mediated sympathetic tone. We hypothesized that due to antagonism between central and local controls, the response of the facial cutaneous microcirculation to acute postural change will be weaker than that in the leg, where these two mechanisms reinforce each other. Cutaneous microvascular flow was measured by laser Doppler flowmetry simultaneously at the shin and the neck of 7 male and 3 female subjects. Subjects underwent a stepwise tilt protocol from standing control to 54 deg head-up tilt (HUT), 30 deg, 12 deg, O deg, -6 deg (HDT), -12 deg, -6 deg, O deg, 12 deg, 30 deg, 54 deg, and standing, for 30-sec periods with 10-sec transitions between postures. Flows at the shin and the neck increased significantly (P less than 0.05) from standing baseline to 12 deg HUT (252 +/- 55 and 126 +/- 9% (bar X +/- SE) of baseline, respectively). From 12 deg to -12 deg tilt, flows continued to increase at the shin (509 +/- 71% of baseline) but decreased at the neck to baseline levels (100 +/- 15% of baseline). Cutaneous microvascular flow recovered at both sites during the return to standing posture with significant hysteresis. Flow increases from standing to near-supine posture are attributed at both sites to baroreceptor-mediated vasodilation. The great dissimilarity in flow response magnitudes at the two measurement sites may be indicative of central/local regulatory antagonism above heart level and reinforcement below heart level.

  1. Study protocol: the effect of whole body vibration on acute unilateral unstable lateral ankle sprain- a biphasic randomized controlled trial.

    Science.gov (United States)

    Baumbach, Sebastian Felix; Fasser, Mariette; Polzer, Hans; Sieb, Michael; Regauer, Markus; Mutschler, Wolf; Schieker, Matthias; Blauth, Michael

    2013-01-14

    Ankle sprains often result in ankle instability, which is most likely caused by damage to passive structures and neuromuscular impairment. Whole body vibration (WBV) is a neuromuscular training method improving those impaired neurologic parameters. The aim of this study is to compare the current gold standard functional treatment to functional treatment plus WBV in patients with acute unilateral unstable inversion ankle sprains. 60 patients, aged 18-40 years, presenting with an isolated, unilateral, acute unstable inversion ankle sprain will be included in this bicentric, biphasic, randomized controlled trial. Samples will be randomized by envelope drawing. All patients will be allowed early mobilization and pain-dependent weight bearing, limited functional immobilization by orthosis, PRICE, NSARDs as well as home and supervised physiotherapy. Supervised physical therapy will take place twice a week, for 30 minutes for a period of 6 weeks, following a standardized intervention protocol. During supervised physical therapy, the intervention group will perform exercises similar to those of the control group, on a side-alternating sinusoidal vibration platform. Two time-dependent primary outcome parameters will be assessed: short-term outcome after six weeks will be postural control quantified by the sway index; mid-term outcome after one year will be assessed by subjective instability, defined by the presence of giving-way attacks. Secondary outcome parameters include: return to pre-injury level of activities, residual pain, recurrence, objective instability, energy/coordination, Foot and Ankle Disability Index and EQ 5D. This is the first trial investigating the effects of WBV in patients with acute soft tissue injury. Inversion ankle sprains often result in ankle instability, which is most likely due to damage of neurological structures. Due to its unique, frequency dependent, influence on various neuromuscular parameters, WBV is a promising treatment method for

  2. Study protocol: the effect of whole body vibration on acute unilateral unstable lateral ankle sprain- a biphasic randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Baumbach Sebastian Felix

    2013-01-01

    Full Text Available Abstract Background Ankle sprains often result in ankle instability, which is most likely caused by damage to passive structures and neuromuscular impairment. Whole body vibration (WBV is a neuromuscular training method improving those impaired neurologic parameters. The aim of this study is to compare the current gold standard functional treatment to functional treatment plus WBV in patients with acute unilateral unstable inversion ankle sprains. Methods/Design 60 patients, aged 18–40 years, presenting with an isolated, unilateral, acute unstable inversion ankle sprain will be included in this bicentric, biphasic, randomized controlled trial. Samples will be randomized by envelope drawing. All patients will be allowed early mobilization and pain-dependent weight bearing, limited functional immobilization by orthosis, PRICE, NSARDs as well as home and supervised physiotherapy. Supervised physical therapy will take place twice a week, for 30 minutes for a period of 6 weeks, following a standardized intervention protocol. During supervised physical therapy, the intervention group will perform exercises similar to those of the control group, on a side-alternating sinusoidal vibration platform. Two time-dependent primary outcome parameters will be assessed: short-term outcome after six weeks will be postural control quantified by the sway index; mid-term outcome after one year will be assessed by subjective instability, defined by the presence of giving-way attacks. Secondary outcome parameters include: return to pre-injury level of activities, residual pain, recurrence, objective instability, energy/coordination, Foot and Ankle Disability Index and EQ 5D. Discussion This is the first trial investigating the effects of WBV in patients with acute soft tissue injury. Inversion ankle sprains often result in ankle instability, which is most likely due to damage of neurological structures. Due to its unique, frequency dependent, influence on various

  3. Acute and Chronic Whole-Body Vibration Exercise does not Induce Health-Promoting Effects on The Blood Profile

    Directory of Open Access Journals (Sweden)

    Theodorou Anastasios A.

    2015-06-01

    Full Text Available Whole-body vibration (WBV exercise is an alternative, popular and easy exercise that can be followed by general public. Therefore, the aim of the present study was to investigate the influence of acute and chronic WBV exercise on health-related parameters. Twenty-eight women were allocated into a control group (n=11, mean ±SEM: age, 43.5 ±1.5 yr; body mass, 66.1 ±3.1 kg; height, 160.6 ±1.5 cm and a vibration group (n=17, mean ±SEM: age, 44.0 ±1.0 yr; body mass, 67.1 ±2.2 kg; height, 162.5 ±1.5 cm. After baseline assessments, participants of the experimental group performed WBV training 3 times/week for 8 weeks. Before and after the chronic WBV exercise, the participants of the vibration group performed one session of acute WBV exercise. Blood chemistry measurements (hematology, creatine kinase, lactate dehydrogenase, aspartate aminotransferase, alanine aminotransferase, C-reactive protein, glucose, insulin, triacylglycerols, total cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, apolipoprotein A1, apolipoprotein B and lipoprotein, thiobarbituric-acid reactive substances, protein carbonyls, total antioxidant capacity, uric acid, albumin and bilirubin were assessed pre-exercise and post-exercise at the first and eighth week of WBV exercise in both control and vibration groups. The results failed to support any effect of both acute and chronic WBV exercise on biochemical health-related parameters. However, it seems that WBV exercise is a safe way of training without a negative impact on muscle and liver functionality.

  4. Acute non-stochastic effect of very low dose whole-body exposure, a thymidine equivalent serum factor

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; Muehlensiepen, H.; Porschen, W.; Booz, J.

    1982-01-01

    Whole-body irradiation of mice causes the dose-dependent appearance of a humoral factor in blood serum which inhibits incorporation of 125-IUdR into tissue culture cells. This factor appears even at doses below 0.01 Gy gamma irradiation and thus is probably not related to cell death. Data are presented relating this humoral factor to thymidine. Since at low doses the target size for this effect was calculated to be the entire cell, a cellular effect is postulated linking the site of few primary absorption events, anywhere in the cell, with the cellular membrane, thus causing changes in membrane charge, structure and/or fluidity. This may lead to blocking thymidine acceptance by the cell, and thus would cause a pile-up of thymidine in the reutilization pathway in peripheral blood and would give rise to the observed effect. The effect appears as a temporary disturbance of the physiological equilibrium and should not be related at present to any cellular damage. The acute low-dose effect described has implications for the measurement of low-dose exposure by biological dosimeters and on basic research on membrane function. (author)

  5. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  6. Ultrastructural changes in spermatogonia of Wistar strain rats following acute whole-body X-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hrehorovsky, M; Horak, J [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes in spermatogonia ultrastructure in rats of Wistar strain after single whole-body X-ray irradiation with 6.4 mC.kg/sup -1/, 25.8 mC.kg/sup -1/ and 51.6 mC.kg/sup -1/ respectively, were studied. Intracellular spaces were found between spermatogonia enlarged, nuclear membranes were bent, the pheripheral teritories of chromation were electronoptically denser, the morphology of nucleoli was changed, cytoplasm was vacuolised, mitochondria were damaged, the vacuolar dilatation of agranular endoplasmic reticulum was evident and electronoptically empty vacuoles near the Golgi complex occured 48 hours after single whole-body X-ray irradiation. Qualitative changes in the ultrastructure of individual types of spermatogonia after individual exposures were similar.

  7. Radiobiologic considerations about further development of whole-body irradiation with subsequent bone marrow transplantation applied during the treatment of acute leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Trott, K R; Holler, E; Kolb, H J

    1981-08-01

    The results achieved hitherto with whole-body irradiation in case of acute leukemia are examined with respect to the optimization criteria of a radiotherapy. The most important failure risk is the recurrence which occurs in more than 50% of all cases, then follows the interstitial pneumonia. The authors think that an increase of the total dose, the adaption of the dose distribution to the distribution of leukemia cells in the body, and a higher fractionation of the total dose are approaches for improving the therapy results.

  8. Acute effect of whole body vibration on isometric strength, squat jump, and flexibility in well-trained combat athletes

    Directory of Open Access Journals (Sweden)

    Cem Kurt

    2015-02-01

    Full Text Available The purpose of this study was to investigate the effect of whole body vibration (WBV training on maximal strength, squat jump, and flexibility of well-trained combat athletes. Twelve female and 8 male combat athletes (age: 22.8 ± 3.1 years, mass: 65.4 ± 10.7 kg, height: 168.8 ± 8.8 cm, training experience: 11.6 ± 4.7 years, training volume: 9.3 ± 2.8 hours/week participated in this study. The study consisted of three sessions separated by 48 hours. The first session was conducted for familiarization. In the subsequent two sessions, participants performed WBV or sham intervention in a randomized, balanced order. During WBV intervention, four isometric exercises were performed (26 Hz, 4 mm. During the sham intervention, participants performed the same WBV intervention without vibration treatment (0 Hz, 0 mm. Hand grip, squat jump, trunk flexion, and isometric leg strength tests were performed after each intervention. The results of a two-factor (pre-post[2] × intervention[2] repeated measures ANOVA revealed a significant interaction (p = 0.018 of pre-post × intervention only for the hand grip test, indicating a significant performance increase of moderate effect (net increase of 2.48%, d = 0.61 after WBV intervention. Squat jump, trunk flexion, and isometric leg strength performances were not affected by WBV. In conclusion, the WBV protocol used in this study potentiated hand grip performance, but did not enhance squat jump, trunk flexion, or isometric leg strength in well-trained combat athletes.

  9. Acute effect of whole body vibration on isometric strength, squat jump, and flexibility in well-trained combat athletes.

    Science.gov (United States)

    Kurt, C; Pekünlü, E

    2015-06-01

    The purpose of this study was to investigate the effect of whole body vibration (WBV) training on maximal strength, squat jump, and flexibility of well-trained combat athletes. Twelve female and 8 male combat athletes (age: 22.8 ± 3.1 years, mass: 65.4 ± 10.7 kg, height: 168.8 ± 8.8 cm, training experience: 11.6 ± 4.7 years, training volume: 9.3 ± 2.8 hours/week) participated in this study. The study consisted of three sessions separated by 48 hours. The first session was conducted for familiarization. In the subsequent two sessions, participants performed WBV or sham intervention in a randomized, balanced order. During WBV intervention, four isometric exercises were performed (26 Hz, 4 mm). During the sham intervention, participants performed the same WBV intervention without vibration treatment (0 Hz, 0 mm). Hand grip, squat jump, trunk flexion, and isometric leg strength tests were performed after each intervention. The results of a two-factor (pre-post[2] × intervention[2]) repeated measures ANOVA revealed a significant interaction (p = 0.018) of pre-post × intervention only for the hand grip test, indicating a significant performance increase of moderate effect (net increase of 2.48%, d = 0.61) after WBV intervention. Squat jump, trunk flexion, and isometric leg strength performances were not affected by WBV. In conclusion, the WBV protocol used in this study potentiated hand grip performance, but did not enhance squat jump, trunk flexion, or isometric leg strength in well-trained combat athletes.

  10. Transformation of myelodysplastic syndrome to acute myeloid leukemia: a case with whole-body 2- (18F) fluoro-2-deoxy-D-glucose positron emission tomography

    International Nuclear Information System (INIS)

    Liu, Fang; Cao, Qinghua

    2011-01-01

    The case reported here was that of an old woman characterized by pancytopenia, chromosome clonal abnormality, fluctuation of the percent of blast cells at 20%, and negative evidence of malignancy in whole-body 2-( 18 F) fluoro-2-deoxy-D-glucose positron emission tomography ( 18 F-FDG PET). After about 10 months, the blast cells accounted for about 25%, the morphology of which was similar to that of previous ones, and 18 F-FDG PET demonstrated diffusing increased uptake in the right upper leg and lymph nodes and patchy high uptake of bone marrow. 2-( 18 F)-fluoro-2-deoxyglucose can reflect extramedullary infiltration and bone marrow cellularity of the whole body, compared with invasive, regional biopsies and aspirations. The value of 2-( 18 F)-fluoro-2-deoxyglucose or 3'-deoxy-3'-( 18 F)-fluorothymidine positron emission tomography as an indicator in predicting the transformation of myelodysplastic syndrome to acute myeloid leukemia needs to be explored in the future. (author)

  11. Whole body monitoring - Goiania

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Bertelli Neto, L.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: - Individual from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1). - Occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121,57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was established according to the Cs activity present in the body or to the job to be assigned. In this paper we will present some burden activity curves for Cs 137 as a function of the time elapsed from the first measurement. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity x time curve. (author) [pt

  12. Whole body imaging

    International Nuclear Information System (INIS)

    de Luca, P.C.; Stoddart, H.F.; Jeffries, D.

    1976-01-01

    A whole body imaging system rapidly forms a quality image of the bony structure, soft tissue or specific organs of a patient who has been injected with a suitable radioactive tracer chemical. A radiation detector head assembly includes a number of detector subassemblies, each having a lead collimator with tapered holes for admitting gamma radiation from a small area of the patient to a scintillation crystal that converts the gamma rays admitted by the collimator into visible or ultraviolet energy pulses. A photomultiplier converts these pulses into electrical pulses. A row of equally spaced detector subassemblies reciprocate within a nonreciprocating lead shield along the long axis of the array over a distance substantially equal to the separation between adjacent ones of the small areas. Associated electronic and electromechanical apparatus control the reciprocating motion and the longitudinal motion of the radiation detector head assembly, and process the photodetected signals to produce in a relatively short time a visible image of the radiant energy emanating from the whole body of the patient scanned

  13. Transcranial magnetic stimulation probes the excitability of the primary motor cortex: A framework to account for the facilitating effects of acute whole-body exercise on motor processes

    Directory of Open Access Journals (Sweden)

    Karen Davranche

    2015-03-01

    Full Text Available The effects of exercise on decision-making performance have been studied using a wide variety of cognitive tasks and exercise interventions. Although the current literature supports a beneficial influence of acute exercise on cognitive performance, the mechanisms underlying this phenomenon have not yet been elucidated. We review studies that used single-pulse transcranial magnetic stimulation (TMS to probe the excitability of motor structures during whole-body exercise and present a framework to account for the facilitating effects of acute exercise on motor processes. Recent results suggest that, even in the absence of fatigue, the increase in corticospinal excitability classically reported during submaximal and exhausting exercises may be accompanied by a reduction in intracortical inhibition. We propose that reduced intracortical inhibition elicits an adaptive central mechanism that counteracts the progressive reduction in muscle responsiveness caused by peripheral fatigue. Such a reduction would render the motor cortex more sensitive to upstream influences, thus causing increased corticospinal excitability. Furthermore, reduction of intracortical inhibition may account for the more efficient descending drive and for the improvement of reaction time performance during exercise. The adaptive modulation in intracortical inhibition could be implemented through a general increase in reticular activation that would further account for enhanced sensory sensitivity.

  14. Does acute exercise affect the performance of whole-body, psychomotor skills in an inverted-U fashion? A meta-analytic investigation.

    Science.gov (United States)

    McMorris, Terry; Hale, Beverley J; Corbett, Jo; Robertson, Kevin; Hodgson, Christopher I

    2015-03-15

    The primary purpose of this study was to examine, using meta-analytical measures, whether research into the performance of whole-body, psychomotor tasks following moderate and heavy exercise demonstrates an inverted-U effect. A secondary purpose was to compare the effects of acute exercise on tasks requiring static maintenance of posture versus dynamic, ballistic skills. Moderate intensity exercise was determined as being between 40% and 79% maximum power output (ẆMAX) or equivalent, while ≥80% ẆMAX was considered to be heavy. There was a significant difference (Zdiff=4.29, p=0.001, R(2)=0.42) between the mean effect size for moderate intensity exercise (g=0.15) and that for heavy exercise size (g=-0.86). These data suggest a catastrophe effect during heavy exercise. Mean effect size for static tasks (g=-1.24) was significantly different (Zdiff=3.24, p=0.001, R(2)=0.90) to those for dynamic/ballistic tasks (g=-0.30). The result for the static versus dynamic tasks moderating variables point to perception being more of an issue than peripheral fatigue for maintenance of static posture. The difference between this result and those found in meta-analyses examining the effects of acute exercise on cognition shows that, when perception and action are combined, the complexity of the interaction induces different effects to when cognition is detached from motor performance. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Quantitative response of bone marrow colony-forming units (CFU-C and PFU-C) in weaning beagles exposed to acute whole-body γ irradiation

    International Nuclear Information System (INIS)

    Wilson, F.D.; Stitzel, K.A.; Klein, A.K.; Shifrine, M.; Graham, R.; Jones, M.; Bradley, E.; Rosenblatt, L.S.

    1978-01-01

    Using a methylcellulose-supported bone marrow culture system, the dose-response relationships of suspended granulocyte-monocyte colonies (CFU-C) and adherent fibroblastic colonies (PFU-C) were investigated in 2- to 3-month-old beagles exposed to acute whole-body γ irradiation. Groups of weanling beagles were exposed at a rate of 140 R/hr delivered from a 60 Co γ source achieving total exposures ranging from 0 to 586 R. Twenty-four hours following irradiation, bone marrow was collected, plated into methylcellulose, and after 1 week of incubation both colony types were quantitated. In addition, bone marrow cellularity determinations were made for a variety of bones using an 59 Fe-labeling technique. The results show a D 37 for the linear part of the slope of 70 R for CFU-C. Although within the limits of the experiment a D 37 could not be established for the fibroblastic populations, the results indicate a substantial degree of radioresistance for these elements supporting our previous studies on PFU-C, performed on mice, which suggested a D 37 of approximately 400 R for the progenitors of these fibroblastic elements

  16. Alleviation of Motor Impairments in Patients with Cerebral Palsy: Acute Effects of Whole-body Vibration on Stretch Reflex Response, Voluntary Muscle Activation and Mobility

    Directory of Open Access Journals (Sweden)

    Anne Krause

    2017-08-01

    Full Text Available IntroductionIndividuals suffering from cerebral palsy (CP often have involuntary, reflex-evoked muscle activity resulting in spastic hyperreflexia. Whole-body vibration (WBV has been demonstrated to reduce reflex activity in healthy subjects, but evidence in CP patients is still limited. Therefore, this study aimed to establish the acute neuromuscular and kinematic effects of WBV in subjects with spastic CP.Methods44 children with spastic CP were tested on neuromuscular activation and kinematics before and immediately after a 1-min bout of WBV (16–25 Hz, 1.5–3 mm. Assessment included (1 recordings of stretch reflex (SR activity of the triceps surae, (2 electromyography (EMG measurements of maximal voluntary muscle activation of lower limb muscles, and (3 neuromuscular activation during active range of motion (aROM. We recorded EMG of m. soleus (SOL, m. gastrocnemius medialis (GM, m. tibialis anterior, m. vastus medialis, m. rectus femoris, and m. biceps femoris. Angular excursion was recorded by goniometry of the ankle and knee joint.ResultsAfter WBV, (1 SOL SRs were decreased (p < 0.01 while (2 maximal voluntary activation (p < 0.05 and (3 angular excursion in the knee joint (p < 0.01 were significantly increased. No changes could be observed for GM SR amplitudes or ankle joint excursion. Neuromuscular coordination expressed by greater agonist–antagonist ratios during aROM was significantly enhanced (p < 0.05.DiscussionThe findings point toward acute neuromuscular and kinematic effects following one bout of WBV. Protocols demonstrate that pathological reflex responses are reduced (spinal level, while the execution of voluntary movement (supraspinal level is improved in regards to kinematic and neuromuscular control. This facilitation of muscle and joint control is probably due to a reduction of spasticity-associated spinal excitability in favor of giving access for greater supraspinal input during voluntary motor

  17. Short Duration Small Sided Football and to a Lesser Extent Whole Body Vibration Exercise Induce Acute Changes in Markers of Bone Turnover

    Directory of Open Access Journals (Sweden)

    J. L. Bowtell

    2016-01-01

    Full Text Available We aimed to study whether short-duration vibration exercise or football sessions of two different durations acutely changed plasma markers of bone turnover and muscle strain. Inactive premenopausal women (n=56 were randomized to complete a single bout of short (FG15 or long duration (FG60 small sided football or low magnitude whole body vibration training (VIB. Procollagen type 1 amino-terminal propeptide (P1NP was increased during exercise for FG15 (51.6±23.0 to 56.5±22.5 μg·L−1, mean ± SD, P0.05. An increase in osteocalcin was observed 48 h after exercise (P<0.05, which did not differ between exercise groups. C-terminal telopeptide of type 1 collagen was not affected by exercise. Blood lactate concentration increased during exercise for FG15 (0.6±0.2 to 3.4±1.2 mM and FG60 (0.6±0.2 to 3.3±2.0 mM, but not for VIB (0.6±0.2 to 0.8±0.4 mM (P<0.05. Plasma creatine kinase increased by 55±63% and 137±119% 48 h after FG15 and FG60 (P<0.05, but not after VIB (26±54%, NS. In contrast to the minor elevation in osteocalcin in response to a single session of vibration exercise, both short and longer durations of small sided football acutely increased plasma P1NP, osteocalcin, and creatine kinase. This may contribute to favorable effects of chronic training on musculoskeletal health.

  18. The problem of the recuperative capacity of mammals after acute sublethal whole-body exposure to high-energy radiation, with special regard to the juvenile organism

    International Nuclear Information System (INIS)

    Baumann, B.

    1978-01-01

    After a single acute whole-body irradiation with 200 kV x-rays (1.5 mm Cu, dose rate 45 min -1 ), radiosensitivitis (LD 50/30d) have been determined in 9 age groups of lactating mice and compared with those of adult mice. In split-dose experiments (Dc = 300 R) recovery rates after 1, 2, 3, 5, 10, and 100 days of recovery have been determined in animals 1, 6, 12, 16, and 80 days old; further examinations have been carried out after 3 days of recovery in 6 day-old animals. The findings are compared with earlier investigations in the same strain of animals and with literature on comparable investigations in mice and other mammals. During infancy, there is a slight, age-dependent increase in radiation resistance after a single exposure, and adult mice are about 10% more radiosensitive than juveniles. The recovery rate of lactating mice increases until 2 hours after irradiation, as in adult animals. In contrast to the values measured in adults, however, the recovery rate of animals 1 and 6 days old then drops to values of -27% resp. -63% of Dc = 300 R after 1 resp. 3 days: Sensitization. In animals 12 and 16 days old, too there is a decrease in recovery after 2 hours, but no marked sensitization. In all animals pre-irradiated in infancy, the recovery rate after 10 days is not higher than 45%, and even after 100 days there is a clear residual damage. In animals 6 days old, which are particularly radiosensitive, the highest sensitization was found 3 days after a pre-irradiation dose of 150 to 200 R, and a saturation of the sensitization mechanism was derived for higher doses. Biological causes of sensitization are still unknown. According to the author's literature studies, other species of mammals, too do not always follow the assumptions on the recuperative capacity of mammal organisms which have been derived from studies in adult mice. (orig.) [de

  19. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  20. The ORNL whole body counter

    International Nuclear Information System (INIS)

    1988-01-01

    This report is a non-technical document intended to provide an individual about to undergo a whole-body radiation count with a general understanding of the counting procedure and with the results obtained. 9 figs

  1. Human whole body cold adaptation.

    NARCIS (Netherlands)

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  2. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  3. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  4. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  5. Short duration small sided football and to a lesser extent whole body vibration exercise induce acute changes in markers of bone turnover

    DEFF Research Database (Denmark)

    Bowtell, Joanna L.; Jackman, Sarah R; Scott, Suzanne

    2016-01-01

    .8 ± 15.1 to 36.6 ± 14.7 μg·L(-1), P > 0.05). An increase in osteocalcin was observed 48 h after exercise (P type 1 collagen was not affected by exercise. Blood lactate concentration increased during exercise for FG15 (0......) small sided football or low magnitude whole body vibration training (VIB). Procollagen type 1 amino-terminal propeptide (P1NP) was increased during exercise for FG15 (51.6 ± 23.0 to 56.5 ± 22.5 μg·L(-1), mean ± SD, P

  6. Whole-body MRI screening

    Energy Technology Data Exchange (ETDEWEB)

    Puls, Ralf [HELIOS Klinikum Erfurt (Germany). Inst. of Diagnostic and Interventional Radiology and Neuroradiology; Hosten, Norbert (ed.) [Universitaetsklinikum Greifswald (Germany). Diagnostic Radiology and Neuroradiology

    2014-07-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  7. Whole-body MRI screening

    International Nuclear Information System (INIS)

    Puls, Ralf; Hosten, Norbert

    2014-01-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  8. Human whole body cold adaptation.

    OpenAIRE

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    ABSTRACT Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000?y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations...

  9. Changes in circulating angiogenic factors after an acute training bout before and after resistance training with or without whole-body-vibration training

    Science.gov (United States)

    Beijer, Åsa; Degens, Hans; May, Francisca; Bloch, Wilhelm; Rittweger, Joern; Rosenberger, Andre

    2012-07-01

    Both Resistance Exercise and Whole-Body-Vibration training are currently considered as countermeasures against microgravity-induced physiological deconditioning. Here we investigated the effects of whole-body vibration superimposed upon resistance exercise. Within this context, the present study focuses on changes in circulating angiogenic factors as indicators of skeletal muscle adaption. Methods: Twenty-six healthy male subjects (25.2 ± 4.2 yr) were included in this two-group parallel-designed study and randomly assigned to one of the training interventions: either resistance exercise (RE) or resistance vibration exercise (RVE). Participants trained 2-3 times per week for 6 weeks (completing 16 training sessions), where one session took 9 ± 1 min. Participants trained with weights on a guided barbell. The individual training load was set at 80% of their 1-Repetition-Maximum. Each training session consisted of three sets with 8 squats and 12 heel raises, following an incremental training design with regards to weight (RE and RVE) and vibration frequency (RVE only). The vibration frequency was increased from 20 Hz in the first week till 40 Hz during the last two weeks with 5-Hz weekly increments. At the first and 16 ^{th} training session, six blood samples (pre training and 2 min, 5 min, 15 min, 35 min and 75 min post training) were taken. Circulating levels of vascular endothelial growth factor (VEGF), Endostatin and Matrix Metalloproteinases -2 and -9 (MMPs) were determined in serum using Enzyme-linked Immunosorbent Assays. Results: MMP-2 levels increased by 7.0% (SE = 2.7%, P < 0.001) within two minutes after the exercise bout and then decreased to 5.7% below baseline (SE = 2.4%, P < 0.001) between 15 and 75 minutes post exercise. This response was comparable before and after the training programs (P = 0.70) and also between the two intervention groups (P = 0.42). Preliminary analyses indicate that a similar pattern applies to circulating MMP-9, VEGF and

  10. Whole body autoradiography, ch. 13

    International Nuclear Information System (INIS)

    Jonkman, J.H.G.

    1977-01-01

    The distribution of 35 S-ringlabelled thiazinamium methylsulphate has been studied by means of whole body autoradiography in a squirrel and in mice. Accumulation of activity was found in liver, kidney and intestines (the excretion of pathways). High concentrations were also found in organs with high amount of acetylcholine receptors and in the glandular tissue. No radioactivity was seen in the central nervous system, indicating no passage through the 'blood-brain barrier'. This is the most significant difference with its tertiary analogue Prometharine hydrochloride. In pregnant mice, high concentrations were found in the placenta but only low amounts were found in liver and kidneys of the foetuses

  11. Human whole body cold adaptation.

    Science.gov (United States)

    Daanen, Hein A M; Van Marken Lichtenbelt, Wouter D

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000 y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations, but also physiological adaptations to cold. Dedicated studies show that repeated whole body exposure of individual volunteers, mainly Caucasians, to severe cold results in reduced cold sensation but no major physiological changes. Repeated cold water immersion seems to slightly reduce metabolic heat production, while repeated exposure to milder cold conditions shows some increase in metabolic heat production, in particular non-shivering thermogenesis. In conclusion, human cold adaptation in the form of increased metabolism and insulation seems to have occurred during recent evolution in populations, but cannot be developed during a lifetime in cold conditions as encountered in temperate and arctic regions. Therefore, we mainly depend on our behavioral skills to live in and survive the cold.

  12. Short Duration Small Sided Football and to a Lesser Extent Whole Body Vibration Exercise Induce Acute Changes in Markers of Bone Turnover

    DEFF Research Database (Denmark)

    Bowtell, J. L.; Jackman, S. R.; Scott, S.

    2016-01-01

    We aimed to study whether short-duration vibration exercise or football sessions of two different durations acutely changed plasma markers of bone turnover and muscle strain. Inactive premenopausal women (n = 56) were randomized to complete a single bout of short (FG15) or long duration (FG60) sm...

  13. An acute bout of whole body passive hyperthermia increases plasma leptin, but does not alter glucose or insulin responses in obese type 2 diabetics and healthy adults.

    Science.gov (United States)

    Rivas, Eric; Newmire, Dan E; Crandall, Craig G; Hooper, Philip L; Ben-Ezra, Vic

    2016-07-01

    Acute and chronic hyperthermic treatments in diabetic animal models repeatedly improve insulin sensitivity and glycemic control. Therefore, the purpose of this study was to test the hypothesis that an acute 1h bout of hyperthermic treatment improves glucose, insulin, and leptin responses to an oral glucose challenge (OGTT) in obese type 2 diabetics and healthy humans. Nine obese (45±7.1% fat mass) type 2 diabetics (T2DM: 50.1±12y, 7.5±1.8% HbA1c) absent of insulin therapy and nine similar aged (41.1±13.7y) healthy non-obese controls (HC: 33.4±7.8% fat mass, Pwhole body passive hyperthermia treatment via head-out hot water immersion (1h resting in 39.4±0.4°C water) that increased internal temperature above baseline by ∆1.6±0.4°C or a control resting condition. Twenty-four hours post treatments, a 75g OGTT was administered to evaluate changes in plasma glucose, insulin, C-peptide, and leptin concentrations. Hyperthermia itself did not alter area under the curve for plasma glucose, insulin, or C-peptide during the OGTT in either group. Fasting absolute and normalized (kg·fat mass) plasma leptin was significantly increased (P<0.01) only after the hyperthermic exposure by 17% in T2DM and 24% in HC groups (P<0.001) when compared to the control condition. These data indicate that an acute hyperthermic treatment does not improve glucose tolerance 24h post treatment in moderate metabolic controlled obese T2DM or HC individuals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Fatal veno-occlusive disease of the liver after chemotherapy, whole-body irradiation and bone marrow transplantation for refractory acute leukaemia

    International Nuclear Information System (INIS)

    Jacobs, P.; Miller, J.L.; Uys, C.J.; Dietrich, B.E.

    1979-01-01

    Rapid onset of liver failure with fatal outcome occured in a young woman after successful bone marrow transplantation undertaken for refractory acute leukaemia. Centrilobular necrosis was demonstrated at autopsy and was attributed to prior cytotoxic chemotherapy, possibly potentiated by the total-body irradiation that was used in preparation for the transplant. This association between liver damage and prolonged drug therapy, coupled with the short median survival currently achieved within these chemotherapy regimens, has initiated an evaluation of bone marrow transplantation in patients with leukaemia during the first complete remission, rather than at a later stage when cumulative drug toxicity to the liver may have taken place

  15. Whole Body Vibration Improves Cognition in Healthy Young Adults

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Van Heuvelen, Marieke J. G.; Zeinstra, Edzard B.; Fuermaier, Anselm B.M.; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van der Zee, Eddy A.

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5 +/- 2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration

  16. The evolution of whole-body imaging.

    LENUS (Irish Health Repository)

    Moran, Deirdre E

    2012-02-01

    This article reviews the evolution of whole-body imaging, discussing the history and development of radiography, nuclear medicine, computed tomography (CT), positron emission tomography (PET), combined PET-CT, and magnetic resonance imaging. The obstacles hindering progress toward whole-body imaging using each of these modalities, and the technical advances that were developed to overcome them, are reviewed. The effectiveness and the limitations of whole-body imaging with each of these techniques are also briefly discussed.

  17. 3D whole body scanners revisited

    NARCIS (Netherlands)

    Daanen, H.A.M.; Haar, F.B. ter

    2013-01-01

    An overview of whole body scanners in 1998 (H.A.M. Daanen, G.J. Van De Water. Whole body scanners, Displays 19 (1998) 111-120) shortly after they emerged to the market revealed that the systems were bulky, slow, expensive and low in resolution. This update shows that new developments in sensing and

  18. Quantitative whole body scintigraphy - a simplified approach

    International Nuclear Information System (INIS)

    Marienhagen, J.; Maenner, P.; Bock, E.; Schoenberger, J.; Eilles, C.

    1996-01-01

    In this paper we present investigations on a simplified method of quantitative whole body scintigraphy by using a dual head LFOV-gamma camera and a calibration algorithm without the need of additional attenuation or scatter correction. Validation of this approach to the anthropomorphic phantom as well as in patient studies showed a high accuracy concerning quantification of whole body activity (102.8% and 97.72%, resp.), by contrast organ activities were recovered with an error range up to 12%. The described method can be easily performed using commercially available software packages and is recommendable especially for quantitative whole body scintigraphy in a clinical setting. (orig.) [de

  19. whole body vibration and spinal stabilisation

    African Journals Online (AJOL)

    A range of exercise modalities is used in the rehabilitation of indi- viduals with chronic lower ... effects of whole body vibration (WBV) therapy and conventional ... with musculoskeletal, sensory, emotional, cognitive and behavioural components ...

  20. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  1. Whole-body counters in Canada

    International Nuclear Information System (INIS)

    Letourneau, C.

    1986-08-01

    A compilation of whole-body counting existing across Canada was prepared by AECB (Atomic Energy Control Board) staff. This work was initiated so that AECB staff and other concerned parties would have this information readily available, especially during urgent situations. This report is to be used for reference purposes only, as it makes no attempt to judge the present state of the art of whole-body counting

  2. Determination of optimal whole body vibration amplitude and frequency parameters with plyometric exercise and its influence on closed-chain lower extremity acute power output and EMG activity in resistance trained males

    Science.gov (United States)

    Hughes, Nikki J.

    The optimal combination of Whole body vibration (WBV) amplitude and frequency has not been established. Purpose. To determine optimal combination of WBV amplitude and frequency that will enhance acute mean and peak power (MP and PP) output EMG activity in the lower extremity muscles. Methods. Resistance trained males (n = 13) completed the following testing sessions: On day 1, power spectrum testing of bilateral leg press (BLP) movement was performed on the OMNI. Days 2 and 3 consisted of WBV testing with either average (5.8 mm) or high (9.8 mm) amplitude combined with either 0 (sham control), 10, 20, 30, 40 and 50 Hz frequency. Bipolar surface electrodes were placed on the rectus femoris (RF), vastus lateralis (VL), bicep femoris (BF) and gastrocnemius (GA) muscles for EMG analysis. MP and PP output and EMG activity of the lower extremity were assessed pre-, post-WBV treatments and after sham-controls on the OMNI while participants performed one set of five repetitions of BLP at the optimal resistance determined on Day 1. Results. No significant differences were found between pre- and sham-control on MP and PP output and on EMG activity in RF, VL, BF and GA. Completely randomized one-way ANOVA with repeated measures demonstrated no significant interaction of WBV amplitude and frequency on MP and PP output and peak and mean EMGrms amplitude and EMG rms area under the curve. RF and VL EMGrms area under the curve significantly decreased (p plyometric exercise does not induce alterations in subsequent MP and PP output and EMGrms activity of the lower extremity. Future studies need to address the time of WBV exposure and magnitude of external loads that will maximize strength and/or power output.

  3. Whole Body Vibration Improves Cognition in Healthy Young Adults

    OpenAIRE

    Regterschot, G. Ruben H.; Van Heuvelen, Marieke J. G.; Zeinstra, Edzard B.; Fuermaier, Anselm B. M.; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van Der Zee, Eddy A.

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5 +/- 2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on ...

  4. Comparison of whole-body-imaging methods

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hoffer, P.

    1977-01-01

    Currently there are four different devices that have found clinical utility in whole-body imaging. These are the rectilinear scanner, the multicrystal whole-body scanner, the Anger-type camera with a whole-body-imaging table, and the tomoscanner. In this text, the basic theory of operation and a discussion of the advantages and disadvantages in whole-body imaging is presented for each device. When applicable, a comparative assessment of the various devices is also presented. As with all else in life, there is no simple answer to the question ''which total body imaging device is best.'' Institutions with a very heavy total-body-imaging load may prefer to use an already available dual-headed rectilinear scanner system for these studies, rather than invest in a new instrument. Institutions with moderate total-body-imaging loads may wish to invest in moving table or moving camera devices which make total body imaging more convenient but retain the basic flexibility of the camera. The large-field Anger camera with or without motion offers another flexible option to these institutions. The laboratory with a very heavy total body imaging load may select efficiency over flexibility, thereby freeing up other instruments for additional studies. Finally, reliability as well as availability and quality of local service must be considered. After all, design features of an instrument become irrelevant when it is broken down and awaiting repair

  5. Small and inconsistent effects of whole body vibration on athletic performance : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Hortobagyi, Tibor; Lesinski, Melanie; Fernandez-del-Olmo, Miguel; Granacher, Urs

    We quantified the acute and chronic effects of whole body vibration on athletic performance or its proxy measures in competitive and/or elite athletes. Systematic literature review and meta-analysis. Whole body vibration combined with exercise had an overall 0.3 % acute effect on maximal voluntary

  6. Whole body MR imaging in diabetes

    International Nuclear Information System (INIS)

    Weckbach, Sabine; Schoenberg, Stefan O.

    2009-01-01

    Diabetes mellitus is a major cardiovascular risk factor and one of the major causes for morbidity and mortality worldwide. Diabetic complications have not only major impact on the quality of life of diabetic patients, but are also potentially life-threatening. Therefore prevention, diagnosis and therapy of these long-term complications are of high importance. However, diagnosis of the variety of complications from diabetes mellitus remains a diagnostic challenge and usually several diagnostic steps are necessary to diagnose or exclude these complications. In the last years whole body magnetic resonance imaging (WB-MRI) including whole body magnetic resonance angiography (WB-MRA) has been introduced for cardiovascular imaging and is now increasingly applied in clinical routine for the workup of patients with cardiovascular disease and for cardiovascular screening. The article summarizes rationales for WB-MRI in diabetes mellitus, technical concepts of disease specific cardiovascular WB-MRI in diabetes mellitus and discusses potential clinical consequences.

  7. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  8. Early diagnosis and monitoring of whole-body accidental exposure

    International Nuclear Information System (INIS)

    Flury-Herard, A.; Jullien, D.

    1987-01-01

    This paper deals with the handling of accidental, acute or protracted, whole-body overexposures. It is complementary to the report DPS 86/07 SEAPS previously published. The criteria for initial classification, as a function of the mean absorbed dose, the clinical and paraclinical evaluation, the monitoring methods and the treatments to undertake are described successively. The basic components of the therapy are the intensive care of the hematological syndrome with blood products transfusions and anti-infection prophylaxy. The indications and conditions for bone-marrow grafts are also discussed [fr

  9. Whole-body monitoring: Goiania case, Brazil

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Dantas, B.M.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: individuals from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1); occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121, 57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was stablished according to the Cs activity present in the body or to the job that will be done. Some body burden activity curves for Cs 137 as a function of the time elapsed from the first measurement, are presented. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity X time curve. (author) [pt

  10. Whole-body intravoxel incoherent motion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Wurnig, Moritz C.; Eberhardt, Christian; Guggenberger, Roman; Boss, Andreas [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Luechinger, Roger [University and ETH Zurich, Institute of Biomedical Technology, Zurich (Switzerland)

    2015-07-15

    To investigate the technical feasibility of whole-body intravoxel incoherent motion (IVIM) imaging. Whole-body MR images of eight healthy volunteers were acquired at 3T using a spin-echo echo-planar imaging sequence with eight b-values. Coronal parametrical whole-body maps of diffusion (D), pseudodiffusion (D*), and the perfusion fraction (F{sub p}) were calculated. Image quality was rated qualitatively by two independent radiologists, and inter-reader reliability was tested with intra-class correlation coefficients (ICCs). Region of interest (ROI) analysis was performed in the brain, liver, kidney, and erector spinae muscle. Depiction of anatomic structures was rated as good on D maps and good to fair on D* and F{sub p} maps. Exemplary mean D (10{sup -3} mm{sup 2}/s), D* (10{sup -3} mm{sup 2}/s) and F{sub p} (%) values (± standard deviation) of the renal cortex were as follows: 1.7 ± 0.2; 15.6 ± 6.5; 20.9 ± 4.4. Inter-observer agreement was ''substantial'' to ''almost perfect'' (ICC = 0.80 - 0.92). The coefficient of variation of D* was significantly lower with the proposed algorithm compared to the conventional algorithm (p < 0.001), indicating higher stability. The proposed IVIM protocol allows computation of parametrical maps with good to fair image quality. Potential future clinical applications may include characterization of widespread disease such as metastatic tumours or inflammatory myopathies. (orig.)

  11. Whole body measurements in Bavarian school children

    International Nuclear Information System (INIS)

    Schmier, H.; Berg, D.

    1992-12-01

    On behalf of the Bavarian State Ministry for State Development and Environmental Affairs measurements were conducted using the whole body counters at the Institute for Radiation Hygiene (of the Federal Office for Radiation Protection), and the Institute for Radiation Biology (of the GSF Research Centre for Environment and Health). Between September 1988 and July 1990 about 1600 school children from all over Bavaria were investigated for incorporated radiocesium. The aim of these measurements was to evaluate the whole body activity due to regionally differing soil contaminations in Bavaria following the accident in the nuclear power plant in Chernobyl and to assess the effective dose from an intake of radionuclides for the pupils by comparing the results of their WBC measurements with those of reference groups of children which underwent WBC examinations at regular intervals at both institutes since the middle of the year 1986. The results of the WBC measurements of those pupils who had not eaten mushrooms in the days before the measurement are in good agreement with the results of comparative measurements in children living in the regions of Munich and Frankfurt-am-Main. Based on these results an effective dose of 0,2 mSv for the Munich region children and of 0,1 mSv for Nothern Bavarian children can be derived. For children living in the highest contaminated region of Bavaria, i.e. the counties adjacent to the Alps, no comparable reference group results are available, but the amount of incorporated radiocesium is only twice that for pupils in the Munich region. The mean value for the specific activity of radiocesium in South Bavarian school children who consumed mushrooms was found to be twice the value of pupils who did not. This is also true for that group of children whose parents had bought allegedly low contaminated foodstuffs. Other effecs of nutrition habits on the specific whole body activity could not be found. (orig.) [de

  12. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  13. Whole body detectors for clinical applications

    International Nuclear Information System (INIS)

    Silar, J.

    The requirements are presented on the parameters of whole-body detectors suitable for clinical retention assays and the detector-patient configuration described. A whole-body detector was developed with an axial configuration of two pairs of large-volume scintillation detectors with NaI(Tl) crystals. One pair is placed under the bed, the other above the bed on which the patient is being examined. The axes of the crystals are located at a distance of 90 cm apart. The field of vision of the detector is described for the application of a 137 Cs source in the air and in a 24 cm layer of water. The positive characteristics of the detector are listed as being homogeneous sensitivity, energy resolution, long-term stability of signal pulse amplitude and average pulse rate in the integral mode. The results obtained show that the detector may be used to evaluate the level of contamination of persons by gamma emitters within the region of approximately 800 Bq to 74 MBq. The error in converting the number of signal pulses in the integral mode does not exceed 50% for gamma emitters with a photon energy above 30O keV. (J.B.)

  14. Whole body acid-base modeling revisited.

    Science.gov (United States)

    Ring, Troels; Nielsen, Søren

    2017-04-01

    The textbook account of whole body acid-base balance in terms of endogenous acid production, renal net acid excretion, and gastrointestinal alkali absorption, which is the only comprehensive model around, has never been applied in clinical practice or been formally validated. To improve understanding of acid-base modeling, we managed to write up this conventional model as an expression solely on urine chemistry. Renal net acid excretion and endogenous acid production were already formulated in terms of urine chemistry, and we could from the literature also see gastrointestinal alkali absorption in terms of urine excretions. With a few assumptions it was possible to see that this expression of net acid balance was arithmetically identical to minus urine charge, whereby under the development of acidosis, urine was predicted to acquire a net negative charge. The literature already mentions unexplained negative urine charges so we scrutinized a series of seminal papers and confirmed empirically the theoretical prediction that observed urine charge did acquire negative charge as acidosis developed. Hence, we can conclude that the conventional model is problematic since it predicts what is physiologically impossible. Therefore, we need a new model for whole body acid-base balance, which does not have impossible implications. Furthermore, new experimental studies are needed to account for charge imbalance in urine under development of acidosis. Copyright © 2017 the American Physiological Society.

  15. Myelopoiesis in whole-body-irradiated beagles

    International Nuclear Information System (INIS)

    Stevenson, A.F.G.

    1985-01-01

    The influence of dose-rate (DR) (either 5.2 or 52 cGy/min.) on the regeneration of bone marrow (BM) myelopoietic progenitor cells was studied in beagles after exposure to whole-body-irradiation (235, 375 and 1500 cGy + autologous BM-transplantation). Myelopoietic progenitor cells were assayed as colony-forming units in agar cultures (GM-CFU), in correlation with the colony-stimulation activity (CSA) in serum. At 235 cGy, the influence of DR on the recovery of GM-CFU was insignificant. However, at 375 cGy, the recovery was critically dependent on the DR. Depletion of GM-CFU numbers elevated CSA levels above pre-irradiation values. The DR determines the regenerative ability when the dose itself is critical to survival of the least number of hematopoietic stem cells (HSC) necessary for restitution. (author)

  16. Possibilities of whole-body MRI for investigating musculoskeletal diseases

    International Nuclear Information System (INIS)

    Lenk, S.; Claussen, C.D.; Schlemmer, H.P.; Fischer, S.; Koetter, I.

    2004-01-01

    This contribution outlines possibilities and limitations of whole-body MRI for investigating musculoskeletal diseases. Benefits and drawbacks of the novel whole-body MRI technology are discussed and a possible whole-body MRI sequence protocol for musculoskeletal examinations is proposed. Muscle, joint and bone diseases are discussed in which the application of whole-body MRI may be of advantage. Particularly, polymyositis, muscledystrophy, rheumatoid arthritis, spondylitis ancylosans, multiple trauma, skeletal metastases, multiple myeloma and malignant lymphoma are mentioned. Whole-body MRI opens new advantages for the examination of multifocal musculoskeletal diseases. The clinical benefit of this method for particular diseases has to be evaluated in further studies, however. (orig.) [de

  17. Whole-body irradiation transiently diminishes the adrenocorticotropin response to recombinant human interleukin-1{alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Perlstein, R.S.; Mehta, N.R.; Neta, R.; Whitnall, M.H. [Armed Forces Radiobiology Research Institute, Bethesda, MD (United States); Mougey, E.H. [Walter Reed Army Institute of Research, Washington, DC (United States)

    1995-03-01

    Recombinant human interleukin-1{alpha} (rhIL-1{alpha}) has significant potential as a radioprotector and/or treatment for radiation-induced hematopoietic injury. Both IL-1 and whole-body ionizing irradiation acutely stimulate the hypothalamic-pituitary-adrenal axis. We therefore assessed the interaction of whole-body irradiation and rhIL-1{alpha} in altering the functioning of the axis in mice. Specifically, we determined the adrenocorticotropin (ACTH) and corticosterone responses to rhIL-1{alpha} administered just before and hours to days after whole-body or sham irradiation. Our results indicate that whole-body irradiation does not potentiate the rhIL-1{alpha}-induced increase in ACTH levels at the doses used. In fact, the rhIL-1{alpha}-induced increase in plasma ACTH is transiently impaired when the cytokine is administered 5 h after, but not 1 h before, exposure to whole-body irradiation. The ACTH response may be inhibited by elevated corticosterone levels after whole-body irradiation, or by other radiation-induced effects on the pituitary gland and hypothalamus. 36 refs., 3 figs.

  18. Whole body vibration exercise training for fibromyalgia.

    Science.gov (United States)

    Bidonde, Julia; Busch, Angela J; van der Spuy, Ina; Tupper, Susan; Kim, Soo Y; Boden, Catherine

    2017-09-26

    Exercise training is commonly recommended for adults with fibromyalgia. We defined whole body vibration (WBV) exercise as use of a vertical or rotary oscillating platform as an exercise stimulus while the individual engages in sustained static positioning or dynamic movements. The individual stands on the platform, and oscillations result in vibrations transmitted to the subject through the legs. This review is one of a series of reviews that replaces the first review published in 2002. To evaluate benefits and harms of WBV exercise training in adults with fibromyalgia. We searched the Cochrane Library, MEDLINE, Embase, CINAHL, PEDro, Thesis and Dissertation Abstracts, AMED, WHO ICTRP, and ClinicalTrials.gov up to December 2016, unrestricted by language, to identify potentially relevant trials. We included randomized controlled trials (RCTs) in adults with the diagnosis of fibromyalgia based on published criteria including a WBV intervention versus control or another intervention. Major outcomes were health-related quality of life (HRQL), pain intensity, stiffness, fatigue, physical function, withdrawals, and adverse events. Two review authors independently selected trials for inclusion, extracted data, performed risk of bias assessments, and assessed the quality of evidence for major outcomes using the GRADE approach. We used a 15% threshold for calculation of clinically relevant differences. We included four studies involving 150 middle-aged female participants from one country. Two studies had two treatment arms (71 participants) that compared WBV plus mixed exercise plus relaxation versus mixed exercise plus relaxation and placebo WBV versus control, and WBV plus mixed exercise versus mixed exercise and control; two studies had three treatment arms (79 participants) that compared WBV plus mixed exercise versus control and mixed relaxation placebo WBV. We judged the overall risk of bias as low for selection (random sequence generation), detection (objectively

  19. Treatment of whole-body radiation accident victims

    International Nuclear Information System (INIS)

    Drum, D.E.; Rappeport, J.M.

    1990-01-01

    This paper discusses how whole-body radiation exposure incidents present a number of unique challenges. The acute, nonstochastic effects of high doses of radiation over 25 rads (0.25 Gy) delivered to humans is generally manifest in rather categorical fashion; depending on the dose, either the patient is largely unharmed functionally or he is seriously injured. Radiation initiates microchemical changes within a nanosecond time frame; there exists no specific therapy to stop or reverse the sequence of events that follow. Thus, the range for effective therapeutic intervention is rather small, between 150 to 1500 rad (1.5 to 15 Gy) for humans. Nevertheless, it is likely that a large uncomplicated exposure to as much as 750 rad (7.5 Gy) might be survivable without dramatic measures such as bone marrow transplantation. Review of the available information about past accidents shows that the majority of radiation accidents are mixed injuries

  20. Whole-body nanoparticle aerosol inhalation exposures.

    Science.gov (United States)

    Yi, Jinghai; Chen, Bean T; Schwegler-Berry, Diane; Frazer, Dave; Castranova, Vince; McBride, Carroll; Knuckles, Travis L; Stapleton, Phoebe A; Minarchick, Valerie C; Nurkiewicz, Timothy R

    2013-05-07

    Inhalation is the most likely exposure route for individuals working with aerosolizable engineered nano-materials (ENM). To properly perform nanoparticle inhalation toxicology studies, the aerosols in a chamber housing the experimental animals must have: 1) a steady concentration maintained at a desired level for the entire exposure period; 2) a homogenous composition free of contaminants; and 3) a stable size distribution with a geometric mean diameter generation of aerosols containing nanoparticles is quite challenging because nanoparticles easily agglomerate. This is largely due to very strong inter-particle forces and the formation of large fractal structures in tens or hundreds of microns in size (6), which are difficult to be broken up. Several common aerosol generators, including nebulizers, fluidized beds, Venturi aspirators and the Wright dust feed, were tested; however, none were able to produce nanoparticle aerosols which satisfy all criteria (5). A whole-body nanoparticle aerosol inhalation exposure system was fabricated, validated and utilized for nano-TiO2 inhalation toxicology studies. Critical components: 1) novel nano-TiO2 aerosol generator; 2) 0.5 m(3) whole-body inhalation exposure chamber; and 3) monitor and control system. Nano-TiO2 aerosols generated from bulk dry nano-TiO2 powders (primary diameter of 21 nm, bulk density of 3.8 g/cm(3)) were delivered into the exposure chamber at a flow rate of 90 LPM (10.8 air changes/hr). Particle size distribution and mass concentration profiles were measured continuously with a scanning mobility particle sizer (SMPS), and an electric low pressure impactor (ELPI). The aerosol mass concentration (C) was verified gravimetrically (mg/m(3)). The mass (M) of the collected particles was determined as M = (Mpost-Mpre), where Mpre and Mpost are masses of the filter before and after sampling (mg). The mass concentration was calculated as C = M/(Q*t), where Q is sampling flowrate (m(3)/min), and t is the sampling

  1. Whole body interaction with public displays

    CERN Document Server

    Walter, Robert

    2017-01-01

    This book develops valuable new approaches to digital out-of-home media and digital signage in urban environments. It offers solutions for communicating interactive features of digital signage to passers-by. Digital out-of-home media and digital signage screens are becoming increasingly interactive thanks to touch input technology and gesture recognition. To optimize their conversion rate, interactive public displays must 1) attract attention, 2) communicate to passers-by that they are interactive, 3) explain the interaction, and 4) provide a motivation for passers-by to interact. This book highlights solutions to problems 2 and 3 above. The focus is on whole-body interaction, where the positions and orientations of users and their individual body parts are captured by specialized sensors (e.g., depth cameras). The book presents revealing findings from a field study on communicating interactivity, a laboratory on analysing visual attention, a field study on mid-air gestures, and a field study on using mid-air...

  2. Whole-body 35-GHz security scanner

    Science.gov (United States)

    Appleby, Roger; Anderton, Rupert N.; Price, Sean; Sinclair, Gordon N.; Coward, Peter R.

    2004-08-01

    A 35GHz imager designed for Security Scanning has been previously demonstrated. That imager was based on a folded conical scan technology and was constructed from low cost materials such as expanded polystyrene and printed circuit board. In conjunction with an illumination chamber it was used to collect indoor imagery of people with weapons and contraband hidden under their clothing. That imager had a spot size of 20mm and covered a field of view of 20 x 10 degrees that partially covered the body of an adult from knees to shoulders. A new variant of this imager has been designed and constructed. It has a field of view of 36 x 18 degrees and is capable of covering the whole body of an adult. This was achieved by increasing the number of direct detection receivers from the 32 used in the previous design to 58, and by implementing an improved optical design. The optics consist of a front grid, a polarisation device which converts linear to circular polarisation and a rotating scanner. This new design uses high-density expanded polystyrene as a correcting element on the back of the front grid. This gives an added degree of freedom that allows the optical design to be diffraction limited over a very wide field of view. Obscuration by the receivers and associated components is minimised by integrating the post detection electronics at the receiver array.

  3. Quantification of interstitial fluid on whole body CT: comparison with whole body autopsy.

    Science.gov (United States)

    Lo Gullo, Roberto; Mishra, Shelly; Lira, Diego A; Padole, Atul; Otrakji, Alexi; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Singh, Sarabjeet; Shepard, Jo-Anne O; Digumarthy, Subba R; Kalra, Mannudeep K; Stone, James R

    2015-12-01

    Interstitial fluid accumulation can occur in pleural, pericardial, and peritoneal spaces, and subcutaneous tissue planes. The purpose of the study was to assess if whole body CT examination in a postmortem setting could help determine the presence and severity of third space fluid accumulation in the body. Our study included 41 human cadavers (mean age 61 years, 25 males and 16 females) who had whole-body postmortem CT prior to autopsy. All bodies were maintained in the morgue in the time interval between death and autopsy. Two radiologists reviewed the whole-body CT examinations independently to grade third space fluid in the pleura, pericardium, peritoneum, and subcutaneous space using a 5-point grading system. Qualitative CT grading for third space fluid was correlated with the amount of fluid found on autopsy and the quantitative CT fluid volume, estimated using a dedicated software program (Volume, Syngo Explorer, Siemens Healthcare). Moderate and severe peripheral edema was seen in 16/41 and 7/41 cadavers respectively. It is not possible to quantify anasarca at autopsy. Correlation between imaging data for third space fluid and the quantity of fluid found during autopsy was 0.83 for pleural effusion, 0.4 for pericardial effusion and 0.9 for ascites. The degree of anasarca was significantly correlated with the severity of ascites (p < 0.0001) but not with pleural or pericardial effusion. There was strong correlation between volumetric estimation and qualitative grading for anasarca (p < 0.0001) and pleural effusion (p < 0.0001). Postmortem CT can help in accurate detection and quantification of third space fluid accumulation. The quantity of ascitic fluid on postmortem CT can predict the extent of anasarca.

  4. Whole body vibration improves cognition in healthy young adults.

    Directory of Open Access Journals (Sweden)

    G Ruben H Regterschot

    Full Text Available This study investigated the acute effects of passive whole body vibration (WBV on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5±2.2 years underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on the Stroop Color-Block Test (CBT, Stroop Color-Word Interference Test (CWIT, Stroop Difference Score (SDS and Digit Span Backward task (DSBT was measured. In half of the passive WBV and control sessions the test order was CBT-CWIT-DSBT, and DSBT-CBT-CWIT in the other half. Passive WBV improved CWIT (p = 0.009; effect size r = 0.20 and SDS (p = 0.034; r = 0.16 performance, but only when the CBT and CWIT preceded the DSBT. CBT and DSBT performance did not change. This study shows that two minutes passive WBV has positive acute effects on attention and inhibition in young adults, notwithstanding their high cognitive functioning which could have hampered improvement. This finding indicates the potential of passive WBV as a cognition-enhancing therapy worth further evaluation, especially in persons unable to perform active forms of exercise.

  5. Whole body vibration improves cognition in healthy young adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Van Heuvelen, Marieke J G; Zeinstra, Edzard B; Fuermaier, Anselm B M; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van Der Zee, Eddy A

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5±2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on the Stroop Color-Block Test (CBT), Stroop Color-Word Interference Test (CWIT), Stroop Difference Score (SDS) and Digit Span Backward task (DSBT) was measured. In half of the passive WBV and control sessions the test order was CBT-CWIT-DSBT, and DSBT-CBT-CWIT in the other half. Passive WBV improved CWIT (p = 0.009; effect size r = 0.20) and SDS (p = 0.034; r = 0.16) performance, but only when the CBT and CWIT preceded the DSBT. CBT and DSBT performance did not change. This study shows that two minutes passive WBV has positive acute effects on attention and inhibition in young adults, notwithstanding their high cognitive functioning which could have hampered improvement. This finding indicates the potential of passive WBV as a cognition-enhancing therapy worth further evaluation, especially in persons unable to perform active forms of exercise.

  6. Whole-body cryotherapy in athletes.

    Science.gov (United States)

    Banfi, Giuseppe; Lombardi, Giovanni; Colombini, Alessandra; Melegati, Gianluca

    2010-06-01

    Cold therapy is commonly used as a procedure to relieve pain symptoms, particularly in inflammatory diseases, injuries and overuse symptoms. A peculiar form of cold therapy (or stimulation) was proposed 30 years ago for the treatment of rheumatic diseases. The therapy, called whole-body cryotherapy (WBC), consists of exposure to very cold air that is maintained at -110 degrees C to -140 degrees C in special temperature-controlled cryochambers, generally for 2 minutes. WBC is used to relieve pain and inflammatory symptoms caused by numerous disorders, particularly those associated with rheumatic conditions, and is recommended for the treatment of arthritis, fibromyalgia and ankylosing spondylitis. In sports medicine, WBC has gained wider acceptance as a method to improve recovery from muscle injury. Unfortunately, there are few papers concerning the application of the treatment on athletes. The study of possible enhancement of recovery from injuries and possible modification of physiological parameters, taking into consideration the limits imposed by antidoping rules, is crucial for athletes and sports physicians for judging the real benefits and/or limits of WBC. According to the available literature, WBC is not harmful or detrimental in healthy subjects. The treatment does not enhance bone marrow production and could reduce the sport-induced haemolysis. WBC induces oxidative stress, but at a low level. Repeated treatments are apparently not able to induce cumulative effects; on the contrary, adaptive changes on antioxidant status are elicited--the adaptation is evident where WBC precedes or accompanies intense training. WBC is not characterized by modifications of immunological markers and leukocytes, and it seems to not be harmful to the immunological system. The WBC effect is probably linked to the modifications of immunological molecules having paracrine effects, and not to systemic immunological functions. In fact, there is an increase in anti

  7. Acute skin reactions observed in fractionated proton irradiation

    International Nuclear Information System (INIS)

    Arimoto, Takuro; Maruhashi, Noboru; Takada, Yoshihisa; Hayakawa, Yoshinori; Inada, Tetsuo; Kitagawa, Toshio

    1989-01-01

    Between May 1985 and July 1987, 49 skin reactions of 43 patients treated by proton irradiation were observed at the Particle Radiation Medical Science Center (PARMS), the University of Tsukuba. Taking the peak skin score as an endpoint, the radiobiological effects [relative biological effectiveness (RBE) and time-dose relationship] of the proton beam in multi-fractionated treatments were estimated. Factors influencing the skin dose, such as the prescribed tumor dose, tumor site, and number of applied fields, were also analyzed. The following conclusions regarding acute skin reactions to the clinical use of proton irradiation were obtained: 1) the physical skin-sparing effect of proton irradiation in single-field irradiation, especially in superficial regions, is not large compared with that of high-energy photon irradiation; 2) multidirectional proton irradiation significantly reduced the skin dose and severity of acute reasons; 3) the radiobiological effects of the proton beam, RBE and the time factor, estimated in human skin in multi-fractional treatment were slightly smaller than those of X-rays, i.e., 0.92 and -0.25±0.09, respectively. (author)

  8. The assessment of whole body bone SPECT in oncology

    International Nuclear Information System (INIS)

    Scortechini, Shonika

    2009-01-01

    Full text: Objectives: To assess the significance and practicability of oncology whole body bone SPECT as part of the standard skeletal survey and its impact on the traditional planar whole body bone imaging protocol. Method: Three consenting oncology patients were injected with a standard adult dose of Tc-99m MOP. Delayed Imaging of whole body sweep and SPECT acquisitions were performed on a Siemens Symbia T6. The patient was positioned supine with arms down with a SPECT scan length covering vortex to thighs. SPECT data was reconstructed and a single whole body zipped file created. Normal SPECT slices along with a cine/MIP of the zipped data were created for review. Results: Both image data sets were reviewed to assess if SPECT provided any further diagnostic clinical information not apparent in planer imaging. In our limited review, whole body SPECT did not add extra value to the planar whole body scans performed; it did however demonstrate vertebral involvement with greater resolution. The processing software and system limitations in seamlessly knitting data sets (creating image artefacts) was a major limiting factor in not pursuing further studies. Conclusion: Both imaging techniques offer differing advantages and limitations, however due to image artefact in the triple knitted SPECT approach with current software technology, it cannot be substituted for whole body imaging at this time.

  9. Acoustical method of whole-body hydration status monitoring

    Science.gov (United States)

    Sarvazyan, A. P.; Tsyuryupa, S. N.; Calhoun, M.; Utter, A.

    2016-07-01

    An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscle is a linear function of water content and can be referenced to the hydration status of the body. Studies on the validity of HM for the assessment of whole-body hydration status were conducted in the Appalachian State University, USA, on healthy young adults and on elderly subjects residing at an assisted living facility. The HM was able to track changes in total body water during periods of acute dehydration and rehydration in athletes and day-to-day and diurnal variability of hydration in elderly. Results of human studies indicate that HM has a potential to become an efficient tool for detecting abnormal changes in the body hydration status.

  10. Enhancement of syngeneic murine tumour transplantability by whole body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.

    1975-01-01

    Experiments were undertaken to test the general validity of the assumption that potentiation of tumour transplantability by sublethal whole body irradiation (WBI) implies some degree of immunological resistance in the intact host. A transplantable carcinoma of spontaneous origin in CBA mice which exhibits a large WBI effect was assayed quantitatively in mice which had been immunologically crippled in terms of allograft acceptance by depletion of thymus derived lymphocytes. The mean number of tumour cells required for 50% successful takes (TD 50 ) in these mice was found to be not significantly different from that in normal controls but highly significantly greater than in WBI mice. On the other hand, in mice which underwent laparotomy immediately before assay, the TD 50 was reduced significantly though not to the same extent as in WBI mice. It was concluded that WBI effect was not due to impaired host immunity but possibly to physiological changes resulting from acute stress. The hypothesis that hyperfibrinogenaemia which occurs after both WBI and laparotomy might increase tumour transplantability was rejected because of the lack of correlation between TD 50 and fibrinogen levels at different times after each procedure. From this and other work it is apparent that TD 50 data, in themselves, give no reliable indication of host immunity. (author)

  11. Whole body scan system based on γ camera

    International Nuclear Information System (INIS)

    Ma Tianyu; Jin Yongjie

    2001-01-01

    Most existing domestic γ cameras can not perform whole body scan protocol, which is of important use in clinic. The authors designed a set of whole body scan system, which is made up of a scan bed, an ISA interface card controlling the scan bed and the data acquisition software based on a data acquisition and image processing system for γ cameras. The image was obtained in clinical experiment, and the authors think it meets the need of clinical diagnosis. Application of this system in γ cameras can provide whole body scan function at low cost

  12. Whole body autoradiography with mice using 14C-thymidine

    International Nuclear Information System (INIS)

    Hruby, R. et al

    1982-06-01

    Whole body autoradiography was performed using common histology equipment. Results were useful with some restrictions. 14C-thymidine and/or itsmetabolites were found in those tissues with high rate of mitosis. (Author)

  13. Comparison of the effects of whole-body cooling during fatiguing exercise in males and females.

    Science.gov (United States)

    Solianik, Rima; Skurvydas, Albertas; Pukėnas, Kazimieras; Brazaitis, Marius

    2015-08-01

    The effects of cold stress on exercise performance and fatigue have been thoroughly investigated only in males, and thus the general understanding of these effects relates only to males. The aim of this study was to determine whether whole-body cooling has different effects on performance during fatiguing exercise in males and females. Thirty-two subjects (18 males and 14 females) were exposed to acute cold stress by intermittent immersion in 14°C water until their rectal temperature reached 35.5°C or for a maximum of 170 min. Thermal responses and motor performance were monitored before and after whole-body cooling. Whole-body cooling decreased rectal, muscle and mean skin temperatures in all subjects (pCold stress decreased the fatigue index (FI) of a sustained 2-min maximal voluntary contraction (MVC) only in males (pbody cooling-induced decrease in the FI of a sustained MVC in males but not in females) supports the view of sex effects on performance during fatiguing exercise after whole-body cooling. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Late biochemical changes in the rat lung after whole body irradiation

    International Nuclear Information System (INIS)

    Dancewicz, A.M.; Kubicka, T.

    1976-01-01

    Young Wistar rats were exposed to 650 R of whole body X-rays then sacrificed at different times after exposure up to one year, and various biochemical parameters in lung tissue were determined. Decrease in protein and elastin content and elevation in fibrinolytic and catheptic activity lasted during the whole observation period. In other parameters a fluctuation, mostly decrease followed by an increase, was seen only during the acute phase of radiation disease. (author)

  15. Cardiopulmonary response during whole-body vibration training in patients with severe COPD

    OpenAIRE

    Rainer Gloeckl; Petra Richter; Sandra Winterkamp; Michael Pfeifer; Christoph Nell; Jeffrey W. Christle; Klaus Kenn

    2017-01-01

    Several studies in patients with chronic obstructive pulmonary disease (COPD) have shown that whole-body vibration training (WBVT) has beneficial effects on exercise capacity. However, the acute cardiopulmonary demand during WBVT remains unknown and was therefore investigated in this study. Ten patients with severe COPD (forced expiratory volume in 1?s: 38?8% predicted) were examined on two consecutive days. On day one, symptom-limited cardiopulmonary exercise testing was performed on a cycle...

  16. Whole-body impedance control of wheeled humanoid robots

    CERN Document Server

    Dietrich, Alexander

    2016-01-01

    Introducing mobile humanoid robots into human environments requires the systems to physically interact and execute multiple concurrent tasks. The monograph at hand presents a whole-body torque controller for dexterous and safe robotic manipulation. This control approach enables a mobile humanoid robot to simultaneously meet several control objectives with different pre-defined levels of priority, while providing the skills for compliant physical contacts with humans and the environment. After a general introduction into the topic of whole-body control, several essential reactive tasks are developed to extend the repertoire of robotic control objectives. Additionally, the classical Cartesian impedance is extended to the case of mobile robots. All of these tasks are then combined and integrated into an overall, priority-based control law. Besides the experimental validation of the approach, the formal proof of asymptotic stability for this hierarchical controller is presented. By interconnecting the whole-body ...

  17. The whole-body counter of the radiation centre Giessen

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    The layout of the whole-body counter at the institute for biophysics of the Giessen radiation centre is decribed. With suitable collimators, the whole-body counter may be used to determine the radioactivity in human and animal organs. The shielding and the measuring and waiting rooms for the patients are described with regard to their technical details. The whole-body counting system enables the radioactivity and the retention of various radioisotopes (e.g. 58 Co-vitamin B 12 , 40 K, 54 Mn, 137 Co, 131 J, 22 Na) to be measured. The estimation of the radiation exposure due to different types of examinations in nuclear medicine, in terms of the critical organs for each type of examination, is very accurate with this counting device. (GSE) [de

  18. Whole body MRI in children; Ganzkoerper-MRT bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Juergen F.; Tsiflikas, Ilias [Tuebingen Univ. (Germany). Bereich Kinderradiologie

    2014-09-15

    In pediatric patients whole body MRI has a relevant impact on both, diagnostic work-up and treatment. Using adapted sequence protocols comprehensive imaging without radiation exposure is possible avoiding additional examinations in many cases. Especially in bone marrow the differentiation between normal and abnormal finding can be difficult, therefore the knowledge of normal maturing of organs is important. Whole body diffusion weighted imaging particularly in neuroblastomas or sarcomas improves the low specificity of conventional MR-protocols. Technical prerequisites, examination protocol and strategies, image interpretation, indications and clinical relevance as well as advantages and disadvantages of whole body MRI will be discussed on the basis of application-oriented cases and the literature.

  19. Proton MR spectroscopy in patients with acute temporal lobe seizures.

    Science.gov (United States)

    Castillo, M; Smith, J K; Kwock, L

    2001-01-01

    Decreases in N-acetyl aspartate (NAA) as seen by proton MR spectroscopy are found in hippocampal sclerosis, and elevated levels of lipids/lactate have been observed after electroconvulsive therapy. Our purpose was to determine whether increased levels of lipids/lactate are found in patients with acute seizures of hippocampal origin. Seventeen patients with known temporal lobe epilepsy underwent proton MR spectroscopy of the mesial temporal lobes within 24 hours of their last seizure. Four of them were restudied when they were seizure-free. Five healthy individuals were used as control subjects. All MR spectroscopy studies were obtained using a single-voxel technique with TEs of 135 and 270. The relationship between the presence of lipids/lactate and seizures was tested using Fisher's exact test. Mean and standard deviations for NAA/creatine (Cr) were obtained in the hippocampi in patients with seizures on initial and follow-up studies and these values were compared with those in the control subjects. Seizure lateralization was obtained in 15 patients. Of the 17 seizure locations that involved hippocampi, 16 showed lipids/lactate by proton MR spectroscopy. Of the 13 hippocampi not directly affected by seizures, 10 showed no lipids/lactate and three showed lipids/lactate. The relationship between lipids/lactate and seizure location was confirmed. A comparison of NAA/Cr ratios for the involved hippocampi with those in control subjects showed significant differences on initial MR spectroscopy; however, no significant difference was found between acute and follow-up NAA/Cr ratios in hippocampi affected by seizures. Lipids/lactate were present in the hippocampi of patients with acute seizures and decreased when the patients were seizure-free. Thus, lipids/lactate may be a sensitive marker for acute temporal lobe seizures.

  20. Measurement of whole body cellular and collagen nitrogen, potassium, and other elements by neutron activation and whole body counting

    International Nuclear Information System (INIS)

    James, H.M.; Fabricius, P.J.; Dykes, P.W.

    1987-01-01

    Whole body nitrogen can be measured by neutron activation analysis with an acceptable radiation dose; it is an index of body protein which, in normal subjects, is 65% cellular protein and 35% extracellular connective collagen. Whole body potassium can be measured by whole body counting without irradiating the subject; it is an index of body cell mass. We measured whole body nitrogen, potassium, extracellular water, intracellular water, and fat-folds. The differences between 37 malnourished patients and five normal subjects suggested that the patients had 9 kg less cell mass than normal, but no difference in extracellular mass. Measurements were made on eight patients before and after 14 days of total parenteral nutrition; balance of nitrogen intake and excretion also was measured. The changes were consistent with mean increases of 3 kg of cellular mass and 3 kg of fat with no change of extracellular mass. The accuracy and sensitivity of the whole body measurements need further confirmation for use in patients with changing body composition. Where tissue wasting is largely from the cellular compartment, potassium could be a more sensitive index of wasting than nitrogen. Multielement analysis of nitrogen, potassium, chlorine, and carbon will probably be valuable in elucidating body composition in malnutrition

  1. Intercalibration of CDTN and IRD whole body counters

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Alonso, T.C.

    2008-01-01

    Full text: Intercalibration exercises are designed to harmonize analytical techniques and ensure reliability of measurement results performed in a laboratory network. Such strategy helps to improve laboratory performance among participants in future intercomparison exercises, when it is verified the metrological capacity, by determining accuracy, precision and reproducibility of data produced by each laboratory. In Brazil, there are currently four in vivo monitoring systems, located in IRD, in Rio de Janeiro, CDTN, in Belo Horizonte, IPEN, in Sao Paulo and CNAAA, in Angra dos Reis. Such systems, generically referred as whole body counters, aim to detect and quantify radionuclides in organs and tissues for radiological protection purposes and to provide useful information for studies on biokinetic behavior of radionuclides in humans and animals. The objective of this work is to establish a methodology to be applied for intercalibration of whole body counters. The IRD whole body counter is installed in a 15 cm steel shielded room where two NaI(Tl) and four HPGe detectors are calibrated for the determination of radionuclides in the energy range from 10 to 3000 keV. The CDTN whole body counter has one NaI detector set up in a shadow shield configuration, and is able to determine radionuclides emitting photons from 100 to 2000 keV. The intercalibration exercise described in this work was planed for whole body geometry using the scintillation detectors available in both laboratories. It was used a thin glass vial containing 2,6615 g of a solution of four gamma emitters ( 57 Co, 137 Cs, 54 Mn, 65 Zn), supplied by the National Laboratory for Metrology of Ionizing Radiation (LNMRI-IRD). The glass vial was measured in the same geometry in both IRD and CDTN whole body counters, being positioned at 31,5 cm distance from the NaI(Tl) detector of each laboratory. The calibration curves (photo peak channel and Efficiency vs Energy) of each detection system were compared. The

  2. Whole-body microvascular permeability of small molecules in man

    DEFF Research Database (Denmark)

    Henriksen, J H

    1985-01-01

    In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured by the indica......In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured...

  3. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1990-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV) ane....... This anesthetic technique and the stethoscope have been used in seven children. The total IV anesthesia proved to be a useful method for children during whole body radiation. The modified stethoscope functioned very well and was a useful complement to the monitoring equipment....

  4. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1991-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV) ane....... This anesthetic technique and the stethoscope have been used in seven children. The total IV anesthesia proved to be a useful method for children during whole body radiation. The modified stethoscope functioned very well and was a useful complement to the monitoring equipment....

  5. RBE of heavy ions (carbon, neon, helium, proton) for acute cell death of pancreatic islet cells

    International Nuclear Information System (INIS)

    Tsubouchi, Susumu; Fukutsu, Kumiko; Itsukaichi, Hiromi

    2003-01-01

    At this fiscal year, only two times irradiation experiments with neon and helium beams were performed to obtain relative biological effectiveness (RBE) of heavy ions (carbon, neon, helium, proton) for acute cell death of pancreatic islet cells in vivo. First of all this project was designed to obtain RBE of 290 MeV carbon and 400 MeV neon beams in the high linear energy transfer (LET) region for acute cell death of pancreatic islets of golden hamster (Mesocricetus auratus) in the condition of in both in vivo and in vitro systems. As mentioned in previous report, in vitro system, however, resulted in ill success. This in vitro experiment was tentatively shelved for the time being. In return in vivo experiments for low LET region of neon beams (32.5 KeV/u), carbon beams (15.0 KeV/u) and helium beams (2 KeV/u) were performed in these two years. Last year these results together with those previously obtained for 200 KeV X-ray, 70 MeV proton, 290 MeV carbon (60 KeV/u), and neon (100 KeV/u) beams were reconsidered. At this year dose response relations (25, 50, 100, 150, and 200 Gy respectively) in acute cell death of pancreatic islets studied histologically after whole body irradiation of 3 weeks young male golden hamster with lower LET helium beams (2 KeV/u) and neon beams (32.5 KeV/u). Results indicated that mean cell lethal dose (Do) of helium beams (2 KeV/u) and neon beams (32.5 KeV/u) were 38 Gy and 49 Gy, respectively. Previously obtained Do data for 200 KeV x-ray, 70 MeV proton, 290 MeV carbon (15 KeV/u), 400 MeV neon (32.5 KeV/u), 290 MeV carbon (60 KeV/u), and 400 MeV neon (100 KeV/u) beams were 37 Gy, 38 Gy, 38 Gy, 49 Gy, 75 Gy, and 200 Gy, respectively. From these data estimated RBE of neon (100 KeV/u and 32.5 KeV/u), carbon (60 KeV/u and 15.0 KeV/u), 70 MeV proton and 150 MeV helium (2 KeV/u) beams were 0.19, 0.76, 0.49, 0.97, 0.97, 0.97, respectively. Therefore the order of RBE (or radiosensitivities) of islets cells with these various heavy ion beams was

  6. Whole-body magnetic resonance imaging in axial spondyloarthritis

    DEFF Research Database (Denmark)

    Krabbe, Simon; Østergaard, Mikkel; Eshed, Iris

    2018-01-01

    Objective. To investigate whether adalimumab (ADA) reduces whole-body (WB-) magnetic resonance imaging (MRI) indices for inflammation in the entheses, peripheral joints, sacroiliac joints, spine, and the entire body in patients with axial spondyloarthritis (axSpA). Methods. An investigator-initia...

  7. Whole-body MR imaging of bone marrow

    International Nuclear Information System (INIS)

    Schmidt, G.P.; Schoenberg, S.O.; Reiser, M.F.; Baur-Melnyk, A.

    2005-01-01

    In clinical routine, multimodality algorithms, including X-ray, computed tomography, scintigraphy and MRI, are used in case of suspected bone marrow malignancy. Skeletal scintigraphy is widely used to asses metastatic disease to the bone, CT is the technique of choice to assess criteria of osseous destruction and bone stability. MRI is the only imaging technique that allows direct visualization of bone marrow and its components with high spatial resolution. The combination of unenhanced T1-weighted-spin echo- and turbo-STIR-sequences have shown to be most useful for the detection of bone marrow abnormalities and are able to discriminate benign from malignant bone marrow changes. Originally, whole-body MRI bone marrow screening was performed in sequential scanning techniques of five body levels with time consuming coil rearrangement and repositioning of the patient. The introduction of a rolling platform mounted on top of a conventional MRI examination table facilitated whole-body MR imaging and, with the use of fast gradient echo, T1-weighted and STIR-imaging techniques, for the first time allowed whole-body imaging within less than one hour. With the development of parallel imaging techniques (PAT) in combination with global matrix coil concepts, acquisition time could be reduced substantially without compromises in spatial resolution, enabling the implementation of more complex and flexible examination protocols. Whole-body MRI represents a new alternative to the stepwise multimodality concept for the detection of metastatic disease, multiple myeloma and lymphoma of the bone with high diagnostic accuracy

  8. The A.R.L. whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1990-02-01

    This report describes a Whole Body Monitor based on four uncollimated NaI(Tl) detectors in a static geometry in use at the Australian Radiation Laboratory. A detailed discussion is presented on the methodology used to estimate the detector efficiency for any arbitrary source whose shape can be described analytically. This procedure is valid for photon emitters in the range 120 keV to 2.6 MeV. By the use of simple geometric models, this approach is applied to the whole body as well as for certain internal organs. For lower photon energies, a discussion of methods using NaI(Tl) detectors to detect in-vivo sources by analysis of pulse-height spectra, is presented. In addition, the application of the Whole Body Monitor in the study of human calcium metabolism, using the tracer 47 Ca is described. Results of measurments on the natural activity of possible candidates for components of the concrete base of the Whole Body Monitor are presented. 74 refs., 22 tabs., 40 figs

  9. Whole body vibration improves body mass, flexibility and strength in ...

    African Journals Online (AJOL)

    Objectives. This study aimed to determine the effectiveness of whole body vibration (WBV) training for promoting healthrelated physical fitness in sedentary adults. Design. A non-randomised sampling technique was used with an equivalent match-pair comparison group, pre- and posttest design. Volunteers were gathered ...

  10. Interventions for chronic low back pain: whole body vibration and ...

    African Journals Online (AJOL)

    Objectives. This study explored, described and compared the effects of whole body vibration (WBV) therapy and conventional spinal stabilisation exercises in persons with chronic low back pain (CLBP). Design. A non-randomised sampling technique was used to delineate the base of volunteers gathered by a combination ...

  11. The effect of whole body vibration exercise on muscle activation ...

    African Journals Online (AJOL)

    African Journal for Physical Activity and Health Sciences ... The effect of whole body vibration exercise (WBV) on muscle activation has recently been a topic for discussion amongst some researchers. ... Participants then performed two different exercises: standing calf raises and prone bridging, without and with WBV.

  12. Whole-Body and Hepatic Insulin Resistance in Obese Children

    Science.gov (United States)

    Ibarra-Reynoso, Lorena del Rocío; Pisarchyk, Liudmila; Pérez-Luque, Elva Leticia; Garay-Sevilla, Ma. Eugenia; Malacara, Juan Manuel

    2014-01-01

    Background Insulin resistance may be assessed as whole body or hepatic. Objective To study factors associated with both types of insulin resistance. Methods Cross-sectional study of 182 obese children. Somatometric measurements were registered, and the following three adiposity indexes were compared: BMI, waist-to-height ratio and visceral adiposity. Whole-body insulin resistance was evaluated using HOMA-IR, with 2.5 as the cut-off point. Hepatic insulin resistance was considered for IGFBP-1 level quartiles 1 to 3 (HOMA-IR was negatively associated with IGFBP-1 and positively associated with BMI, triglycerides, leptin and mother's BMI. Girls had increased HOMA-IR. IGFBP-1 was negatively associated with waist-to-height ratio, age, leptin, HOMA-IR and IGF-I. We did not find HOMA-IR or IGFBP-1 associated with fatty liver. Conclusion In school-aged children, BMI is the best metric to predict whole-body insulin resistance, and waist-to-height ratio is the best predictor of hepatic insulin resistance, indicating that central obesity is important for hepatic insulin resistance. The reciprocal negative association of IGFBP-1 and HOMA-IR may represent a strong interaction of the physiological processes of both whole-body and hepatic insulin resistance. PMID:25411786

  13. Improved measurement system for the whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1983-01-01

    A static four-detector system has been established as a whole body radioactivity measurement system. A technique is being developed to position the detectors in such a manner as to minimise longitudinal distribution effects within a subject. This technique, which represents the human body as a simple geometric model, requires the determination of efficiency at any point within this model

  14. Whole body vibration improves attention and motor performance in ...

    African Journals Online (AJOL)

    Background: Whole body vibration (WBV) is a form of physical stimulation via mechanical vibrations transmitted to a subject. It is assumed that WBV induces sensory stimulation in cortical brain regions through the activation of skin and muscle receptors responding to the vibration. The effects of WBV on muscle strength are ...

  15. Visuospatial memory computations during whole-body rotations in roll

    NARCIS (Netherlands)

    Pelt, S. van; Gisbergen, J.A.M. van; Medendorp, W.P.

    2005-01-01

    We used a memory-saccade task to test whether the location of a target, briefly presented before a whole-body rotation in roll, is stored in egocentric or in allocentric coordinates. To make this distinction, we exploited the fact that subjects, when tilted sideways in darkness, make systematic

  16. Exercise Enhances Whole-Body Cholesterol Turnover in Mice

    NARCIS (Netherlands)

    Meissner, Maxi; Havinga, Rick; Boverhof, Renze; Kema, Ido; Groen, Albert K.; Kuipers, Folkert

    MEISSNER, M., R. HAVINGA, R. BOVERHOF, I. KEMA, A. K. GROEN, and F. KUIPERS. Exercise Enhances Whole-Body Cholesterol Turnover in Mice. Med. Sci. Sports Exerc., Vol. 42, No. 8, pp. 1460-1468, 2010. Purpose: Regular exercise reduces cardiovascular risk in humans by reducing cholesterol levels, but

  17. Detection of metastatic thyroid carcinoma through whole body counting

    International Nuclear Information System (INIS)

    Novenario, H.S.; Pascacio, F.M.; Cruz, Benjamin de la; Anden, A.B.

    Whole body counters are not only used in measuring radioactivity in the body for radiation protection purposes but also in the measurement of iron absorption, body potassium and cesium, chronic blood loss, and also in the determination of the effectiveness of surgery, thyroid hormone and radioactive iodine therapy in thyroid carcinoma. This report deals with our experience in the use of a shadow-shield whole body counter in the determination of I-131 uptake by metastatic lesions of cancer of thyroid after total thyroidectomy and ablation therapy with I-131. This study was undertaken jointly by the Department of Nuclear Medicine, Veterans Memorial Hospital and the Biomedical Research Division of the Philippine Atomic Energy Commission. Preliminary results indicate that the 22 patients who underwent whole body counting after total thyroidectomy I-131 ablation therapy, 9 patients had elevated percentage retention of I-131, 10 patients with normal values and 3 patients with rising values. Foci of I-131 concentration in those with elevated and rising percentage concentration values were seen in the thyroidal bed scintiscans, while the 10 patients with normal values had negative scintiscans. The results of our observations confirm the results obtained by other workers abroad. Our preliminary results indicate that with the use of whole body counters a sensitive method of assessing whether functioning metastatic lesion of cancer of the thyroid still exist after total thyroidectomy and I-131 ablation therapy can be provided. (author)

  18. Corrections of the whole body counting for various measurement geometries

    International Nuclear Information System (INIS)

    Fueloep, M.; Ragan, P.; Lahham, A.

    1996-01-01

    A simple method was suggested for making corrections during the calibration of HPGe detectors employed for the whole-body counting of humans ranging from infants to adults. The results obtained by calculations were verified by using phantoms. (P.A.). 1 tab., 5 figs., 3 refs

  19. The Influence of Whole-Body Vibration on Creatine Kinase Activity and Jumping Performance in Young Basketball Players

    Science.gov (United States)

    Fachina, Rafael; da Silva, Antônio; Falcão, William; Montagner, Paulo; Borin, João; Minozzo, Fábio; Falcão, Diego; Vancini, Rodrigo; Poston, Brach; de Lira, Claudio

    2013-01-01

    Purpose: To quantify creatine kinase (CK) activity changes across time following an acute bout of whole-body vibration (WBV) and determine the association between changes in CK activity and jumping performance. Method: Twenty-six elite young basketball players were assigned to 3 groups: 36-Hz and 46-Hz vibration groups (G36 and G46, respectively)…

  20. Whole-body counting of Fukushima residents after the TEPCO Fukushima Daiichi Nuclear Power Station accident

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Takumaro; Takada, Chie; Nakagawa, Takahiro; Nakai, Katsuta; Kurihara, Osamu; Tsujimura, Norio; Furuta, Sadaaki [Japan Atomic Energy Agency, Nuclear Fuel Cycle Engineering Laboratories, Tokai, Ibaraki (Japan); Ohi, Yoshihiro; Murayama, Takashi; Suzuki, Takashi [Japan Atomic Energy Agency, Nuclear Science Research Institute, Tokai, Ibaraki (Japan); Uezu, Yasuhiro [Japan Atomic Energy Agency, Fukushima Environmental Safety Center, Fukushima, Fukushima (Japan)

    2012-11-15

    At the request of the Fukushima government, the Japan Atomic Energy Agency (JAEA) started whole-body counting of residents on July 11, 2011, to assess radiation exposure after the TEPCO Fukushima Daiichi Nuclear Power Station accident. JAEA has examined residents in Iitate, Kawamata, Namie, and eight other local communities. The measurement capacity of the whole-body counting device is approximately 100 persons per day, and the total number of people to measure reached 9,927 by the end of January 2012. Two types of whole-body counter (WBC), each of which has two large-sized NaI(Tl) detectors, were used to perform the measurements. Physical phantoms (a Canberra RMC-II transfer phantom or a water-filled block phantom developed by JAEA) were used to perform the efficiency calibration of the WBCs, and results of this calibration were verified by comparing them with different-sized BOttle Mannequin ABsorber (BOMAB) phantoms imitating an adult male, a 10-year-old child, and a 4-year-old child. Short half-life radionuclides (e.g., {sup 131}I) originating from the accident were not detected in the present work, because the measurements were made starting four months after the accident. These measurements showed that about 80% of the residents were below a minimum detectable amount (MDA) of the measured radionuclides in the whole-body content. No artificial nuclides other than {sup 134}Cs and {sup 137}Cs were detected in the present whole-body counting. The maximum whole-body content of radiocesium ({sup 134}Cs and {sup 137}Cs in total) was 2.7 kBq for children (< 8 years old) and 14 kBq for adults. The radioactivity ratio ({sup 137}Cs/{sup 134}Cs) was estimated to be from 1.12 to 1.26. An acute intake scenario via inhalation of radiocesium was assumed in the present dose estimation for all the residents who were measured by the end of January 2012. The committed effective dose (CED) to 99.8% of the residents was found to be below 1 mSv. There were only 25 subjects with a

  1. Neurogenic Effects of Low-Dose Whole-Body HZE (Fe) Ion and Gamma Irradiation.

    Science.gov (United States)

    Sweet, Tara B; Hurley, Sean D; Wu, Michael D; Olschowka, John A; Williams, Jacqueline P; O'Banion, M Kerry

    2016-12-01

    Understanding the dose-toxicity profile of radiation is critical when evaluating potential health risks associated with natural and man-made sources in our environment. The purpose of this study was to evaluate the effects of low-dose whole-body high-energy charged (HZE) iron (Fe) ions and low-energy gamma exposure on proliferation and differentiation of adult-born neurons within the dentate gyrus of the hippocampus, cells deemed to play a critical role in memory regulation. To determine the dose-response characteristics of the brain to whole-body Fe-ion vs. gamma-radiation exposure, C57BL/6J mice were irradiated with 1 GeV/n Fe ions or a static 137 Cs source (0.662 MeV) at doses ranging from 0 to 300 cGy. The neurogenesis was analyzed at 48 h and one month postirradiation. These experiments revealed that whole-body exposure to either Fe ions or gamma radiation leads to: 1. An acute decrease in cell division within the dentate gyrus of the hippocampus, detected at doses as low as 30 and 100 cGy for Fe ions and gamma radiation, respectively; and 2. A reduction in newly differentiated neurons (DCX immunoreactivity) at one month postirradiation, with significant decreases detected at doses as low as 100 cGy for both Fe ions and gamma rays. The data presented here contribute to our understanding of brain responses to whole-body Fe ions and gamma rays and may help inform health-risk evaluations related to systemic exposure during a medical or radiologic/nuclear event or as a result of prolonged space travel.

  2. Evidence of impaired learning during whole-body vibration

    Science.gov (United States)

    Sherwood, N.; Griffin, M. J.

    1992-01-01

    A study of the effects of whole-body vibration on learning and memory was conducted, in which a context-dependent experimental design was used. Forty subjects completed a simple associative learning task, half during exposure to 16 Hz whole-body sinusoidal vertical vibration at 2.0 m s -2 r.m.s. and half while static. The results show that the rates of learning of the two groups differed, with that of the vibrated subjects significantly impaired. A second session, one week later, indicated that information learnt in one vibration environment could be recalled equally well in a different environment, suggesting no context-dependent effects on memory processes.

  3. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  4. Natural β-carotene and whole body irradiation in rats

    International Nuclear Information System (INIS)

    Ben-Amotz, A.; Rachmilevich, B.; Greenberg, S.; Sela, M.; Weshler, Z.

    1996-01-01

    β-Carotene and other carotenoids are reported to be potent free radical quenchers, singlet oxygen scavengers, and lipid antioxidants. Whole-body irradiation is known to cause an immunosuppression effect in mammals through the possible initiation and production of reactive oxygen species. We decided to test the possible antioxidative effect against whole-body irradiation of a natural β-carotene, composed of equal amounts of the all-trans and 9-cis isomers, obtained from the unicellular alga Dunaliella bardawil. Rats were fed on ground commercial food enriched with natural β-carotene (50 mg/kg diet). On completion of 1 week with β-carotene, the rats were exposed to a single dose of 4 Gy whole-body irradiation, after which their livers and blood were removed for β-carotene and retinol analysis in comparison with control livers of animals irradiated or not, or supplemented with β-carotene after irradiation. A normal increase in body weight with no ill effects was noted in the groups of rats whose diet was supplemented by β-carotene before and after irradiation, compared with the reduction in the specific growth rate in the group of rats irradiated without β-carotene. Liver β-carotene and retinol decreased significantly after irradiation compared with the rats which were not irradiated. This decrease was not shown in rats fed β-carotene prior to irradiation, and the effect of irradiation was partially cured by supplementation with β-carotene after irradiation. High-pressure liquid chromatography (HPLC) analysis of the irradiated animals showed a selective decline in 9-cis β-carotene and in retinol over all-trans β-carotene and retinyl esters. These results suggest that 9-cis β-carotene and retinol protect in vivo against the cellular damage by free radicals induced after whole-body irradiation. (orig.). With 1 fig., 2 tabs

  5. Rifaximin diminishes neutropenia following potentially lethal whole-body radiation.

    Science.gov (United States)

    Jahraus, Christopher D; Schemera, Bettina; Rynders, Patricia; Ramos, Melissa; Powell, Charles; Faircloth, John; Brawner, William R

    2010-07-01

    Terrorist attacks involving radiological or nuclear weapons are a substantial geopolitical concern, given that large populations could be exposed to potentially lethal doses of radiation. Because of this, evaluating potential countermeasures against radiation-induced mortality is critical. Gut microflora are the most common source of systemic infection following exposure to lethal doses of whole-body radiation, suggesting that prophylactic antibiotic therapy may reduce mortality after radiation exposure. The chemical stability, easy administration and favorable tolerability profile of the non-systemic antibiotic, rifaximin, make it an ideal potential candidate for use as a countermeasure. This study evaluated the use of rifaximin as a countermeasure against low-to-intermediate-dose whole-body radiation in rodents. Female Wistar rats (8 weeks old) were irradiated with 550 cGy to the whole body and were evaluated for 30 d. Animals received methylcellulose, neomycin (179 mg/kg/d) or variably dosed rifaximin (150-2000 mg/kg/d) one hour after irradiation and daily throughout the study period. Clinical assessments (e.g. body weight) were made daily. On postirradiation day 30, blood samples were collected and a complete blood cell count was performed. Animals receiving high doses of rifaximin (i.e. 1000 or 2000 mg/kg/d) had a greater increase in weight from the day of irradiation to postirradiation day 30 compared with animals that received placebo or neomycin. For animals with an increase in average body weight from irradiation day within 80-110% of the group average, methylcellulose rendered an absolute neutrophil count (ANC) of 211, neomycin rendered an ANC of 334, rifaximin 300 mg/kg/d rendered an ANC of 582 and rifaximin 1000 mg/kg/d rendered an ANC of 854 (P = 0.05 for group comparison). Exposure to rifaximin after near-lethal whole-body radiation resulted in diminished levels of neutropenia.

  6. Acid-base status after whole-body irradiation in dairy cows

    International Nuclear Information System (INIS)

    Schaefer, M.; Koch, F.; Dyrba, W.; Kirbach, M.

    1989-01-01

    Whole-body irradiation using 9 MeV X-rays of a linear accelerator of 10 clinically healthy lactating cows aged between 3.5 and 8 years produced an acute radiation syndrome in the LD 100/30 range. Blood analysis 1 day after irradiation showed a compensated metabolic acidosis with a low renal net acid-base excretion and hyerphosphaturia. Later the acid-base status indicated a differently marked metabolic alkalosis. In the main reaction period acidotic disturbances occurred, which partially were camouflaged by respiratory alkalosis. (author)

  7. Measurements of whole-body radioactivity in the UK population

    International Nuclear Information System (INIS)

    Fenwick, J.D.; Boddy, K.; McKenzie, A.L.; Oxby, C.B.

    1992-01-01

    A national survey of whole-body radioactivity was undertaken. A mobile whole-body counter visited collaborating Medical Physics Departments and Hospitals in England and Wales. Data were also obtained from an installed whole-body counter at the West Cumberland Hospital, Whitehaven, and from a control site at Addenbrooke's Hospital, Cambridge. 1657 volunteer members of the public were measured, including 162 children. 36% of volunteers had been measured in a similar survey 2 years earlier, and showed between a two and five fold reduction in body radiocaesium. No radiocaesium was detected in 54% of people measured. Measurements showed a progressive fall over the course of the study, reaching a baseline of 0.3 Bq 137 Cs/gK. In 1989, the additional radiation dose incurred from radiocaesium varied from a maximum of 4.1 μSv in Cumbria to 1.5 μSv in the South East, compared with the average annual radiation dose of 2500 μSv due to all other causes. No other gamma-emitting radionuclides were found. Results are consistent with Chernobyl as the source of the radiocaesium detected. (author)

  8. Measurement of Organ Uptake by Whole-Body Counting

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1970-01-01

    This paper reviews methods for the measurement of radioactivity in body organs based on whole-body radioactivity measurements. Such measurements can of course only be used to measure radioactivity in a body organ when the radioactivity is exclusively localized in the organ or when the ratio of radioactivity in the organ to that in the whole body is known from other sources of information. They find particular applications, however, when the organ is so widely dispersed throughout the body that more localized measurement is impossible. Examples of situations in which whole-body radioactivity measurements have been used in this way are cited. The more important techniques used for such measurements are described and their respective advantages and disadvantages indicated. The importance of uniformity of counting efficiency with position of source throughout the body is stressed. Simple systems incorporating sodium iodide crystal scintillation detectors are shown to combine satisfactory sensitivity and uniformity of efficiency for clinical measurements of radioactivity in body organs and have the additional advantage that they can be readily adapted for profile scanning. Systems incorporating plastic or liquid scintillation detectors are less convenient in this respect. (author)

  9. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  10. Mosquito bite anaphylaxis: immunotherapy with whole body extracts.

    Science.gov (United States)

    McCormack, D R; Salata, K F; Hershey, J N; Carpenter, G B; Engler, R J

    1995-01-01

    Adverse reactions to mosquito bites have been recognized for some time. These usually consist of large local swellings and redness, generalized urticaria, angioedema and less easily definable responses such as nausea, dizziness, headaches, and lethargy. We report two patients who experienced systemic anaphylaxis from mosquito bites. Both were skin tested and given immunotherapy using whole body mosquito extracts. Skin testing using whole body mosquito extracts was positive to Aedes aegypti at 1/1,000 weight/volume (wt/vol) in one patient and to Aedes aegypti at 1/100,000 wt/vol, and Culex pipiens at 1/10,000 wt/vol in the other. Skin testing of ten volunteers without a history of adverse reactions to mosquito bites was negative. Immunotherapy using these extracts resulted in resolution of adverse reactions to mosquito bites in one patient and a decrease in reactions in the other. Immunotherapy with whole body mosquito extracts is a viable treatment option that can play a role in patients with mosquito bite-induced anaphylaxis. It may also result in severe side effects and one must determine the benefit versus risks for each individual patient.

  11. Whole-body gene expression pattern registration in Platynereis larvae.

    Science.gov (United States)

    Asadulina, Albina; Panzera, Aurora; Verasztó, Csaba; Liebig, Christian; Jékely, Gáspár

    2012-12-03

    Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere) of the Platynereis trochophore larva and used for the detailed study of neuronal development. Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2'-thiodiethanol (TDE), which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP) in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4'6-diamidino-2-phenylindole (DAPI). Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental stage. We then registered to these templates the

  12. Whole-body gene expression pattern registration in Platynereis larvae

    Directory of Open Access Journals (Sweden)

    Asadulina Albina

    2012-12-01

    Full Text Available Abstract Background Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere of the Platynereis trochophore larva and used for the detailed study of neuronal development. Results Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2’-thiodiethanol (TDE, which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4’6-diamidino-2-phenylindole (DAPI. Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental

  13. Dynamics of human whole body amino acid metabolism

    International Nuclear Information System (INIS)

    Young, V.R.

    1981-01-01

    The mechanism of regulation of the nitrogen metabolism in humans under various nutritional and physiological states was examined using stable isotopes. In the simultaneous continuous infusion of 1- [ 13 ] - leucine and α- [ 15 N]- lysine, their fluxed decreased when individuals received lower protein intake. The rates of oxidation and incorporation into body proteins of leucine changed in parallel with the protein intake. Such effects of diet on whole body leucine kinetics were modified by the energy state and dietary energy level. The nitrogen balance was also improved by an excess level of dietary energy. When the intake of dietary protein was lowered below the maintenance level, the whole body flux and de novo synthesis of glycine were lowered, but alanine synthesis was clearly increased. The intravenous infusion of glucose at 4 mg/kg.min, which causes increase in excess blood sugar and plasma insulin, increased the alanine flux, but had no effect on the glycine flux. The rate of albumin synthesis, determined by giving 15 N-glycine orally every 3 hr, decreased with the lowered intake of dietary protein in young men, but not in elderly men. This explains why the serum albumin synthesis increases with the increase in the intake of dietary protein in young men, but not in elderly men. The rate of whole body protein synthesis in young men receiving the L-amino acid diets providing with the required intake of specific amino acid was much lower than that in the men receiving the diets providing with generous intake of specific amino acid. Thus the control mechanism to maintain the homeostasis of body nitrogen and amino acids is related in some unknown way to the nutritional requirement of the hosts. (Kaihara, S.)

  14. Whole-body angular momentum during stair ascent and descent.

    Science.gov (United States)

    Silverman, Anne K; Neptune, Richard R; Sinitski, Emily H; Wilken, Jason M

    2014-04-01

    The generation of whole-body angular momentum is essential in many locomotor tasks and must be regulated in order to maintain dynamic balance. However, angular momentum has not been investigated during stair walking, which is an activity that presents a biomechanical challenge for balance-impaired populations. We investigated three-dimensional whole-body angular momentum during stair ascent and descent and compared it to level walking. Three-dimensional body-segment kinematic and ground reaction force (GRF) data were collected from 30 healthy subjects. Angular momentum was calculated using a 13-segment whole-body model. GRFs, external moment arms and net joint moments were used to interpret the angular momentum results. The range of frontal plane angular momentum was greater for stair ascent relative to level walking. In the transverse and sagittal planes, the range of angular momentum was smaller in stair ascent and descent relative to level walking. Significant differences were also found in the ground reaction forces, external moment arms and net joint moments. The sagittal plane angular momentum results suggest that individuals alter angular momentum to effectively counteract potential trips during stair ascent, and reduce the range of angular momentum to avoid falling forward during stair descent. Further, significant differences in joint moments suggest potential neuromuscular mechanisms that account for the differences in angular momentum between walking conditions. These results provide a baseline for comparison to impaired populations that have difficulty maintaining dynamic balance, particularly during stair ascent and descent. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Effect of whole body irradiation on different tissues

    International Nuclear Information System (INIS)

    Casati, V.; Nardino, A.; Tomassi, I.; Becciolini, A.; Rizzi, M.; Martelli, T.

    1979-01-01

    The uptake and elimination of 14 C leucine were analysed in controls and in rats irradiated 2 h before injection with 8 Gy whole-body irradiation. Plasma, small intestine, kidney and skin were assayed after homogenization for TCA soluble and insoluble activity curves. In highly differentiated tissues with poor proliferative activity and low protein turnover, the uptake and elimination of the tracer did not appear to be affected by irradiation. In the small intestine differences between control and irradiated animals seemed significant. (Auth.)

  16. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  17. Start up of the whole body detection system

    International Nuclear Information System (INIS)

    Cortes P, A.; Angeles C, A.; Cuapio O, A.; Tejera R, A.

    1991-12-01

    The management of Radiological Safety of the Nuclear Center of Mexico has a whole body detection system Trade mark Canberra, manufactured by Bio-nuclear Measurements Inc. Ipswich Massachusetts. These systems are used to detect contamination of I-131 in thyroid and other nuclides (Cs-137, Cs-134, Co-60, etc.) in thorax. In this work the procedure that was continued for the setting in march of the thyroid detector is presented. A description of this system and an analysis of the uncertainties involved in the measures of activity of I-131 in thyroid of people occupationally exposed is made. (Author)

  18. The A.E.E. Winfrith Whole Body Monitor

    International Nuclear Information System (INIS)

    Peabody, C.O.; Fraser, V.M.; Speight, R.G.

    1962-10-01

    The function, design and construction of the A.E.E. Winfrith Whole Body Monitor are described. The main purpose of the monitor is to measure gamma emitting radioisotopes in the human body. Its performance, capabilities and limitations are discussed and a summary is given of experience gained and results obtained during the first few months of operation. The future programme of measurements and development is outlined. Some basic design criteria are put forward as a result of the experience and results obtained. (author)

  19. Whole-body magnetic resonance imaging in inflammatory arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Eshed, Iris; Althoff, Christian E.

    2017-01-01

    Objective: Whole-body magnetic resonance imaging (WB-MRI) is a relatively new technique that can enable assessment of the overall inflammatory status of people with arthritis, but standards for image acquisition, definitions of key pathologies, and a quantification system are required. Our aim...... was to perform a systematic literature review (SLR) and to develop consensus definitions of key pathologies, anatomical locations for assessment, a set of MRI sequences and imaging planes for the different body regions, and a preliminary scoring system for WB-MRI in inflammatory arthritis. Methods: An SLR...

  20. Whole-body and multispectral photoacoustic imaging of adult zebrafish

    Science.gov (United States)

    Huang, Na; Xi, Lei

    2016-10-01

    Zebrafish is a top vertebrate model to study developmental biology and genetics, and it is becoming increasingly popular for studying human diseases due to its high genome similarity to that of humans and the optical transparency in embryonic stages. However, it becomes difficult for pure optical imaging techniques to volumetric visualize the internal organs and structures of wild-type zebrafish in juvenile and adult stages with excellent resolution and penetration depth. Even with the establishment of mutant lines which remain transparent over the life cycle, it is still a challenge for pure optical imaging modalities to image the whole body of adult zebrafish with micro-scale resolution. However, the method called photoacoustic imaging that combines all the advantages of the optical imaging and ultrasonic imaging provides a new way to image the whole body of the zebrafish. In this work, we developed a non-invasive photoacoustic imaging system with optimized near-infrared illumination and cylindrical scanning to image the zebrafish. The lateral and axial resolution yield to 80 μm and 600 μm, respectively. Multispectral strategy with wavelengths from 690 nm to 930 nm was employed to image various organs inside the zebrafish. From the reconstructed images, most major organs and structures inside the body can be precisely imaged. Quantitative and statistical analysis of absorption for organs under illumination with different wavelengths were carried out.

  1. Safety aspects of whole-body cryochamber and cryosauna operation

    Science.gov (United States)

    Agnieszka, Piotrowska

    2017-12-01

    Interest in low temperature treatment is constantly increasing. Whole-body cryotherapy (WBC) devices are becoming available not only in medical centers but also in local gyms and spa centers. A new group of users are professional sport clubs where 3-minutes session of whole-body cryotherapy is post-training procedure to improve and speed up the recovery process. There are four different types of WBC devices available on the market and offered to commercial (non-medical) users. The American and European market is dominated by two of them: classic cryochambers and cryosaunas. Both constructions are supplied with liquid nitrogen. Low temperature inside classic cryochamber is produced by evaporating of liquid nitrogen in two or more heat exchangers. There is never a direct contact between user and cryogenic medium in any of system operation mode (closed supply system). Cryosauna is cooled down by filling with cold vapor of liquid nitrogen. Supply system is considered open because it allows for direct contact between user and cryogenic medium. Open supply system of cryosauna is primary and most questionable issue of its operational safety, particularly after tragic accident in October 2015. This paper presents the comparative analysis of classic cryochamber and cryosauna from safety point of view. Both devices have been analyzes and tested on existing systems in operation. Paper gives detailed analysis of constructions, supply systems and working parameters. Special attention has been focused to problem of oxygen deficiency hazard. Different failure or accident scenarios have been analyzed and discussed.

  2. Whole-body vibration exercise in postmenopausal osteoporosis

    Directory of Open Access Journals (Sweden)

    Magdalena Weber-Rajek

    2015-01-01

    Full Text Available The report of the World Health Organization (WHO of 2008 defines osteoporosis as a disease characterized by low bone mass and an increased risk of fracture. Postmenopausal osteoporosis is connected to the decrease in estrogens concentration as a result of malfunction of endocrine ovarian function. Low estrogens concentration causes increase in bone demineralization and results in osteoporosis. Physical activity, as a component of therapy of patients with osteoporosis, has been used for a long time now. One of the forms of safe physical activity is the vibration training. Training is to maintain a static position or execution of specific exercises involving the appropriate muscles on a vibrating platform, the mechanical vibrations are transmitted to the body of the patient. According to the piezoelectric theory, pressure induces bone formation in the electrical potential difference, which acts as a stimulant of the process of bone formation. Whole body vibration increases the level of growth hormone and testosterone in serum, preventing sarcopenia and osteoporosis. The aim of this study was to review the literature on vibration exercise in patients with postmenopausal osteoporosis based on the PubMed and Medline database. While searching the database, the following key words were used ‘postmenopausal osteoporosis’ and ‘whole-body vibration exercise’.

  3. The Health Effects and Keep Down of Whole Body Vibration

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2014-04-01

    Full Text Available Vibration was defined that oscillation of the body according to the reference point. The tools that are used in industry and are the source of vibration cause diseases. For this reason, the vibration has been one of the factors that affect the health and of the most widely researched in the field of ergonomics. The perceived intensity and health effects of vibration depend on the vibration frequency, intensity, direction, acceleration, duration of exposure, vibration affects the region, age, gender, posture, distance from the source person, activity, time of day and the person\\s overall health condition. The one of the most common health effects of whole body vibration is impact on musculoskeletal system. In many studies, indicated that whole-body vibration effect waist, back, shoulder and neck especially. There were varied studies that hormone levels were not changed as well there were varied studies that hormone levels were increased or decreased. There were varied studies about the digestive and circulatory system. In these studies, digestive system complaints, peptic ulcer, gastritis, varicose veins and hemorrhoids were determined frequently. For protection the health effect of vibration, Directives of the European Commission, Turkish Standards, Assessment and Management of Environmental Noise and Vibration Regulations were published. For the control of vibration are need technical and medical measures and education [TAF Prev Med Bull 2014; 13(2.000: 177-186

  4. Nasal reaction to changes in whole body temperature.

    Science.gov (United States)

    Lundqvist, G R; Pedersen, O F; Hilberg, O; Nielsen, B

    1993-11-01

    The changes in nasal patency following a 1.5 degrees C decrease or increase in whole body temperature were measured in 8 healthy young males, during and after 30 min of immersion in a 15 degrees C cold or a 40 degrees C warm bath, breathing air at the same temperature, in a cross-over experimental design. The nasal reactions were traced by consecutive measurements of changes in nasal cavity volumes by acoustic rhinometry. Swelling of the mucosa during cooling and an almost maximal shrinkage of the mucosa during heating were indicated by respectively a decrease and an increase in nasal cavity volumes. The reactions were determined predominantly by the whole body thermal balance, but were also influenced by the temperature of the inhaled air, either enhanced, reduced or temporarily reversed. The greatest change occurred in the nasal cavity, left or right, which differed most from the final state at the beginning of exposure due to the actual state of nasal cycle.

  5. Whole body cooling by immersion in water at moderate temperatures.

    Science.gov (United States)

    Marino, F; Booth, J

    1998-06-01

    This study investigated the potential use of whole body cooling by water immersion for lowering body temperatures prior to endurance exercise. Rectal temperature (Tre), mean skin temperature (Tsk), oxygen consumption (VO2), and ventilation (VE) were measured in 7 male and 3 female subjects who were immersed in a water bath for up to 60 min. Initial water temperature was 28.8+/-1.5 degrees C and decreased to 23.8+/-1.1 degrees C by the end of immersion. Pre-immersion Tre of 37.34+/-0.36 degrees C was not altered by 60 min water immersion but decreased to 36.64+/-0.34 degrees C at 3 min post immersion (p immersion. Reductions in Tre and Tsk resulted in reduced body heat content (Hc) of approximately 545 kJ (p immersion. VO2 and VE increased from pre-immersion values of 0.34+/-0.08 L x min(-1) and 6.2+/-1.4 L x min(-1) to 0.54+/-0.09 L x min(-) and 11.5+/-5.4 L x min(-1) at the end of immersion, respectively. Heart rate remained unchanged throughout immersion. These results indicate that whole body immersion in moderately cold water temperatures is an effective cooling maneuver for lowering body temperatures and body Hc in the absence of severe physiological responses generally associated with sudden cold stress.

  6. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  7. Integrating cellular metabolism into a multiscale whole-body model.

    Directory of Open Access Journals (Sweden)

    Markus Krauss

    Full Text Available Cellular metabolism continuously processes an enormous range of external compounds into endogenous metabolites and is as such a key element in human physiology. The multifaceted physiological role of the metabolic network fulfilling the catalytic conversions can only be fully understood from a whole-body perspective where the causal interplay of the metabolic states of individual cells, the surrounding tissue and the whole organism are simultaneously considered. We here present an approach relying on dynamic flux balance analysis that allows the integration of metabolic networks at the cellular scale into standardized physiologically-based pharmacokinetic models at the whole-body level. To evaluate our approach we integrated a genome-scale network reconstruction of a human hepatocyte into the liver tissue of a physiologically-based pharmacokinetic model of a human adult. The resulting multiscale model was used to investigate hyperuricemia therapy, ammonia detoxification and paracetamol-induced toxication at a systems level. The specific models simultaneously integrate multiple layers of biological organization and offer mechanistic insights into pathology and medication. The approach presented may in future support a mechanistic understanding in diagnostics and drug development.

  8. Integrating Cellular Metabolism into a Multiscale Whole-Body Model

    Science.gov (United States)

    Krauss, Markus; Schaller, Stephan; Borchers, Steffen; Findeisen, Rolf; Lippert, Jörg; Kuepfer, Lars

    2012-01-01

    Cellular metabolism continuously processes an enormous range of external compounds into endogenous metabolites and is as such a key element in human physiology. The multifaceted physiological role of the metabolic network fulfilling the catalytic conversions can only be fully understood from a whole-body perspective where the causal interplay of the metabolic states of individual cells, the surrounding tissue and the whole organism are simultaneously considered. We here present an approach relying on dynamic flux balance analysis that allows the integration of metabolic networks at the cellular scale into standardized physiologically-based pharmacokinetic models at the whole-body level. To evaluate our approach we integrated a genome-scale network reconstruction of a human hepatocyte into the liver tissue of a physiologically-based pharmacokinetic model of a human adult. The resulting multiscale model was used to investigate hyperuricemia therapy, ammonia detoxification and paracetamol-induced toxication at a systems level. The specific models simultaneously integrate multiple layers of biological organization and offer mechanistic insights into pathology and medication. The approach presented may in future support a mechanistic understanding in diagnostics and drug development. PMID:23133351

  9. Whey Protein Supplementation Enhances Whole Body Protein Metabolism and Performance Recovery after Resistance Exercise: A Double-Blind Crossover Study.

    Science.gov (United States)

    West, Daniel W D; Abou Sawan, Sidney; Mazzulla, Michael; Williamson, Eric; Moore, Daniel R

    2017-07-11

    No study has concurrently measured changes in free-living whole body protein metabolism and exercise performance during recovery from an acute bout of resistance exercise. We aimed to determine if whey protein ingestion enhances whole body net protein balance and recovery of exercise performance during overnight (10 h) and 24 h recovery after whole body resistance exercise in trained men. In a double-blind crossover design, 12 trained men (76 ± 8 kg, 24 ± 4 years old, 14% ± 5% body fat; means ± standard deviation (SD)) performed resistance exercise in the evening prior to consuming either 25 g of whey protein (PRO; MuscleTech 100% Whey) or an energy-matched placebo (CHO) immediately post-exercise (0 h), and again the following morning (~10 h of recovery). A third randomized trial, completed by the same participants, involving no exercise and no supplement served as a rested control trial (Rest). Participants ingested [ 15 N]glycine to determine whole body protein kinetics and net protein balance over 10 and 24 h of recovery. Performance was assessed pre-exercise and at 0, 10, and 24 h of recovery using a battery of tests. Net protein balance tended to improve in PRO ( P = 0.064; effect size (ES) = 0.61, PRO vs. CHO) during overnight recovery. Over 24 h, net balance was enhanced in PRO ( P = 0.036) but not in CHO ( P = 0.84; ES = 0.69, PRO vs. CHO), which was mediated primarily by a reduction in protein breakdown (PRO protein supplementation improved MVC (ES = 0.76), REP (ES = 0.44), and peak power (ES = 0.55). In conclusion, whey protein supplementation enhances whole body anabolism, and may improve acute recovery of exercise performance after a strenuous bout of resistance exercise.

  10. Whole-Body CT Screening--Should I or Shouldn't I Get One?

    Science.gov (United States)

    ... Procedures Medical Imaging Medical X-ray Imaging Whole-Body CT Screening--Should I or shouldn't I ... What are the risks and benefits of whole-body CT screening? Many people believe incorrectly that a ...

  11. Between-centre variability versus variability over time in DXA whole body measurements evaluated using a whole body phantom

    Energy Technology Data Exchange (ETDEWEB)

    Louis, Olivia [Department of Radiology, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)]. E-mail: olivia.louis@az.vub.ac.be; Verlinde, Siska [Belgian Study Group for Pediatric Endocrinology (Belgium); Thomas, Muriel [Belgian Study Group for Pediatric Endocrinology (Belgium); De Schepper, Jean [Department of Pediatrics, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)

    2006-06-15

    This study aimed to compare the variability of whole body measurements, using dual energy X-ray absorptiometry (DXA), among geographically distinct centres versus that over time in a given centre. A Hologic-designed 28 kg modular whole body phantom was used, including high density polyethylene, gray polyvinylchloride and aluminium. It was scanned on seven Hologic QDR 4500 DXA devices, located in seven centres and was also repeatedly (n = 18) scanned in the reference centre, over a time span of 5 months. The mean between-centre coefficient of variation (CV) ranged from 2.0 (lean mass) to 5.6% (fat mass) while the mean within-centre CV ranged from 0.3 (total mass) to 4.7% (total area). Between-centre variability compared well with within-centre variability for total area, bone mineral content and bone mineral density, but was significantly higher for fat (p < 0.001), lean (p < 0.005) and total mass (p < 0.001). Our results suggest that, even when using the same device, the between-centre variability remains a matter of concern, particularly where body composition is concerned.

  12. Development of fibrosis in dogs as a late consequence of whole-body X-irradiation

    International Nuclear Information System (INIS)

    Calvo, W.; Fliedner, T.M.; Steinbach, I.; Alcober, V.; Nothdurft, W.; Fache, I.

    1978-01-01

    Dogs wre whole-body irradiated with a single mid-line dose of 1200 R at 300 kV. This high dose will kill non-treated animals within a few days. To save these animals, leukocytes were previously collected during a four-hour leukapheresis using a continuous-flow centrifuge and were stored under liquid nitrogen. Shortly after the whole-body irradiation each dog received its own cryopreserved cells thawed immediately beforehand. The dogs received between 0.32x10 9 and 1.63x10 9 mononuclear blood cells per kilogram of body weight. The number of colony-forming cells contained in the transfusate ranged between 0.19x10 5 and 1.38x10 5 per kilogram of body weight. This blood stem transfusion, together with general supportive therapy, enabled the dogs to overcome the acute radiation syndrome and to recover. The dogs were subsequently sacrificed in two groups after observation for about 260 days or 700-898 days respectively. Pathological findings are described. A particular situation existed in the marrow, whre non-irradiated stem cells had colonized bone cavities containing irradiated stroma. Progressive fibrosis developed in the endosteal areas of the bone cavities in most of the animals. (author)

  13. Electrical stimulation of human lower extremities enhances energy consumption, carbohydrate oxidation, and whole body glucose uptake.

    Science.gov (United States)

    Hamada, Taku; Hayashi, Tatsuya; Kimura, Tetsuya; Nakao, Kazuwa; Moritani, Toshio

    2004-03-01

    Our laboratory has recently demonstrated that low-frequency electrical stimulation (ES) of quadriceps muscles alone significantly enhanced glucose disposal rate (GDR) during euglycemic clamp (Hamada T, Sasaki H, Hayashi T, Moritani T, and Nakao K. J Appl Physiol 94: 2107-2112, 2003). The present study is further follow-up to examine the acute metabolic effects of ES to lower extremities compared with voluntary cycle exercise (VE) at identical intensity. In eight male subjects lying in the supine position, both lower leg (tibialis anterior and triceps surae) and thigh (quadriceps and hamstrings) muscles were sequentially stimulated to cocontract in an isometric manner at 20 Hz with a 1-s on-off duty cycle for 20 min. Despite small elevation of oxygen uptake by 7.3 +/- 0.3 ml x kg(-1) x min(-1) during ES, the blood lactate concentration was significantly increased by 3.2 +/- 0.3 mmol/l in initial period (5 min) after the onset of the ES (P increased anaerobic glycolysis by ES. Furthermore, whole body glucose uptake determined by GDR during euglycemic clamp demonstrated a significant increase during and after the cessation of ES for at least 90 min (P energy consumption, carbohydrate oxidation, and whole body glucose uptake at low intensity of exercise. Percutaneous ES may become a therapeutic utility to enhance glucose metabolism in humans.

  14. [Psychological effects of long-term occupational whole body vibration].

    Science.gov (United States)

    Schneider, H; Wall, H

    1989-04-01

    Long-term effects of occupational whole-body vibration (WBV) on psychic performance and on well-being have hardly been described in the literature to date. However, they cannot be excluded, since numerous findings exist on impairments of performance and of well-being in experimentally conditioned short-term effects. Within the framework of comprehensive clearing-up diagnostics in occupational health, 20 male subjects with many years of occupational exposure to WBV were investigated according to a standardized psychodiagnostic programme of methods. The highest rate of pathological findings resulted in the areas of visual perception speed and subtle motory speed of movements. Furthermore, the results are evidence for an interrelation between the duration of exposure and disturbances in the areas of attention, as well as of sensomotory selection responses. As a whole, the results essentially affect the same psychological variables as the results of the short-term studies, but are to be evaluated with reservations on methodological grounds.

  15. Interpolation method by whole body computed tomography, Artronix 1120

    International Nuclear Information System (INIS)

    Fujii, Kyoichi; Koga, Issei; Tokunaga, Mitsuo

    1981-01-01

    Reconstruction of the whole body CT images by interpolation method was investigated by rapid scanning. Artronix 1120 with fixed collimator was used to obtain the CT images every 5 mm. X-ray source was circully movable to obtain perpendicular beam to the detector. A length of 150 mm was scanned in about 15 min., with the slice width of 5 mm. The images were reproduced every 7.5 mm, which was able to reduce every 1.5 mm when necessary. Out of 420 inspection in the chest, abdomen, and pelvis, 5 representative cases for which this method was valuable were described. The cases were fibrous histiocytoma of upper mediastinum, left adrenal adenoma, left ureter fibroma, recurrence of colon cancer in the pelvis, and abscess around the rectum. This method improved the image quality of lesions in the vicinity of the ureters, main artery, and rectum. The time required and exposure dose were reduced to 50% by this method. (Nakanishi, T.)

  16. Biophysical study of mice blood after whole body irradiation

    Science.gov (United States)

    Saad El Din, Alsha A.; Desouky, Omar S.; El Behay, Amin Z.; El Sayed, Anwar A.

    1996-05-01

    The immediate of whole body fractionated doses of 137Cs gamma rays totalling 13 Gy on mice as well as the late effects of accumulative dose of 10 Gy (8 days after exposure) were studied. Changes due to gamma irradiation in hemoglobin conductivity and buffer capacity indicate the appearance of hydrophobic groups and changes in hydrophilic/hydrophobic ratio. These changes demonstrate different degrees of unfolding and refolding of the hemoglobin molecule. The viscosity coefficient of hemoglobin is found to increase at fractionated doses of 7 and 13 Gy. Such effect seems to be due to aggregation of the protein part of hemoglobin. The fractionated dose of 13 Gy causes changes in the electronic state of oxyhemoglobin indicated by an increase in methemoglobin which reduces biological activity.

  17. A new crystal whole-body scanner for positron emitters

    International Nuclear Information System (INIS)

    Ostertag, H.; Kuebler, W.; Kubesch, R.; Lorenz, W.J.; Woerner, P.

    1980-01-01

    A multicrystal whole body scanner for positron emitters has been constructed. The annihilation quanta are measured in two opposing detector banks. Each detector bank consists of 64 NaI crystals of 1.5'' diameter x 3'' length. Directly opposing single detectors are in coincidence. The patient moves linearly between the stationary transverse detector banks. The scanning area of the system is 64 x 192 cm 2 . The spatial resolution is 2 cm at a sampling distance of 1 cm. The sensitivity is 6400 counts/s for a pure positron flood source with 1 μCi/cm 2 . The system is controlled by a microcomputer (DEC LSI-11). The scintigrams are shown on a display. Absolute activities can be calculated by mathematical comparison of consecutive emission and transmission scans. The design of the positron scanner and its capacibilities are described. Experimental and initial clinical results are presented. (author)

  18. Numerical analysis of whole-body cryotherapy chamber design improvement

    Science.gov (United States)

    Yerezhep, D.; Tukmakova, A. S.; Fomin, V. E.; Masalimov, A.; Asach, A. V.; Novotelnova, A. V.; Baranov, A. Yu

    2018-05-01

    Whole body cryotherapy is a state-of-the-art method that uses cold for treatment and prevention of diseases. The process implies the impact of cryogenic gas on a human body that implements in a special cryochamber. The temperature field in the chamber is of great importance since local integument over-cooling may occur. Numerical simulation of WBC has been carried out. Chamber design modification has been proposed in order to increase the uniformity of the internal temperature field. The results have been compared with the ones obtained for a standard chamber design. The value of temperature gradient formed in the chamber containing curved wall with certain height has been decreased almost twice in comparison with the results obtained for the standard design. The modification proposed may increase both safety and comfort of cryotherapy.

  19. Computational Fluid Dynamics of Whole-Body Aircraft

    Science.gov (United States)

    Agarwal, Ramesh

    1999-01-01

    The current state of the art in computational aerodynamics for whole-body aircraft flowfield simulations is described. Recent advances in geometry modeling, surface and volume grid generation, and flow simulation algorithms have led to accurate flowfield predictions for increasingly complex and realistic configurations. As a result, computational aerodynamics has emerged as a crucial enabling technology for the design and development of flight vehicles. Examples illustrating the current capability for the prediction of transport and fighter aircraft flowfields are presented. Unfortunately, accurate modeling of turbulence remains a major difficulty in the analysis of viscosity-dominated flows. In the future, inverse design methods, multidisciplinary design optimization methods, artificial intelligence technology, and massively parallel computer technology will be incorporated into computational aerodynamics, opening up greater opportunities for improved product design at substantially reduced costs.

  20. Whole body bone scintigraphy in osseous hydatosis: a case report

    Directory of Open Access Journals (Sweden)

    Ebrahimi Abdolali

    2007-09-01

    Full Text Available Abstract Hydatid disease is common in many parts of the world, and causes considerable health and economic loss. This disease may develop in almost any part of the body. Bone involvement is often asymptomatic, and its diagnosis is primarily based on radiographic findings. A whole body bone scan is able to show the extent and distribution of lesions. We describe an unusual case of multifocal skeletal hydatosis and also explain the clinical and diagnostic points. We hope to stimulate a high index of suspicion among clinicians to facilitate early diagnosis and to consider this disease as a differential diagnosis in cases of multiple abnormal activity in bone scintigraphy especially among people in endemic areas.

  1. Investigation of a whole-body DOI-PET system

    International Nuclear Information System (INIS)

    Ohi, Junichi; Tonami, Hiromichi

    2007-01-01

    In this study, we were conducting basic research on a whole-body depth of gamma-ray interaction (DOI) positron emission tomography system which provides spatial resolution that is both high and uniform, and also minimizes costs. The detectors consist of double-layer 9x10 GSO/GSO phoswich crystal blocks, a light guide and two rectangular PMTs. Individual crystal sizes are 2.45x5.1x15 mm 3 , and each layer of crystal blocks has a different decay time. Many of the circuit boards used in our current conventional PET system (SET-3000G SHIMADZU Japan) have been optimized for DOI acquisition. The detectors are arranged to form a 332.5 mm radius detection ring, and spatial resolution is obtained from the center to the edge of the 250 mm radius field of view. The effect of DOI was confirmed using a comparison with the non-DOI systems

  2. Improved rectilinear scanning device for the whole body

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    A rectilinear scanning device for whole-body counting is described in which the spacial resolution is considerably improved upon by using photomultipliers with spherically curved photocathodes. By this measure, the distinct non-linearity between the output signals of the phototubes and the actual position of the scintillation in the scintillation crystal, as observed in plane photocathodes, is removed. The distances between the photomultipliers and the scintillation crystal can thus be kept very small whereby an improved statistic and lower noise can be obtained. Furthermore, thicker crystals can be used whereby the efficiency in the determination of higher energies is increased. The electronic signal processing to the reproduction of the nuclide distribution in the body is described in detail. (ORU/LH) [de

  3. Recent advances in the physiology of whole body immersion.

    Science.gov (United States)

    Gauer, O H

    1975-01-01

    Recent investigations have furnished a complete analysis of the hemodynamic events accompanying whole-body immersion. About 700 ml of blood are translocated into the intrathoracic circulation, and heart volume increases by 180 +/- 62 ml. These changes are followed by an increase in stroke volume and cardiac output of over 30%. At the same time a reflex reduction of total peripheral resistance and venous tone occurs. Renin and aldosterone activity are reduced while the 17-hydroxycorticosteroid is not affected. Treatment of the subject with DOCA attenuates but does not extinguish the excess sodium excretion of immersion. This finding strengthens the arguments in favor of an unknown factor enhancing sodium excretion. Finally, the relative activation of the three factors that serve volume control, the excretory function of the kidney, capillary filtration pressure, and the thirst mechanism, is discussed.

  4. Particular aspects regarding the effects of whole body vibration exposure

    Directory of Open Access Journals (Sweden)

    Picu Mihaela

    2018-01-01

    Full Text Available This paper analyses the influence of whole-body vibrations on human performance; for this it was investigated how a group of men (20-29 years of age and a group of woman (21–31 years of age answered to specific requirements after being subjected to vertical vibrations under controlled laboratory conditions for 10-25 min. The vibrations were generated by a vibrant system with known amplitudes and frequencies. Accelerations were measured with NetdB - complex system for measuring and analysing human vibration and they were found in the range 0.4 - 3.1m/s2. The subjects’ performances were determined for each vibration level using specific tests. It can be concluded that exposure to vibrations higher than those recommended by ISO 2631 significantly disrupts how subjects responded to tests requirements.

  5. Radiological Emergency Preparedness using Old ORTEC Whole Body Counter

    International Nuclear Information System (INIS)

    Badawy, W.M.

    2012-01-01

    During a radiological emergency (RE) a large number of occupational and public may be exposed externally and to a number of radionuclides internally as a result of inhalation or injection. The radiological effect is directly proportional to the time of exposure and the activity of the contaminant materials. The main task of this paper is to show the emergency preparedness capability of using the old ORTEC whole body counter (WBC). In case of a nuclear accident ORTEC WBC is ready for use to estimate the radioactivity which inhaled or digested with food, as well as in case of medical exposure in general and nuclear medicine in particular. The present study showed that the duration time to make analysis for only one individual is about 25 min. Hence 57 individuals are monitored per day. Consequently, old ORTEC WBC is effective tool in field of research and limited use for radiological and nuclear emergencies

  6. Whole-body cryotherapy: empirical evidence and theoretical perspectives

    Directory of Open Access Journals (Sweden)

    Bleakley CM

    2014-03-01

    Full Text Available Chris M Bleakley,1 François Bieuzen,2 Gareth W Davison,1 Joseph T Costello3 1Sport and Exercise Science Research Institute, Faculty of Life and Health Sciences, University of Ulster, Newtownabbey, Northern Ireland; 2Research Department, Laboratory of Sport, Expertise and Performance, French National Institute of Sport (INSEP, Paris, France; 3School of Exercise and Nutrition Sciences and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia Abstract: Whole-body cryotherapy (WBC involves short exposures to air temperatures below –100°C. WBC is increasingly accessible to athletes, and is purported to enhance recovery after exercise and facilitate rehabilitation postinjury. Our objective was to review the efficacy and effectiveness of WBC using empirical evidence from controlled trials. We found ten relevant reports; the majority were based on small numbers of active athletes aged less than 35 years. Although WBC produces a large temperature gradient for tissue cooling, the relatively poor thermal conductivity of air prevents significant subcutaneous and core body cooling. There is weak evidence from controlled studies that WBC enhances antioxidant capacity and parasympathetic reactivation, and alters inflammatory pathways relevant to sports recovery. A series of small randomized studies found WBC offers improvements in subjective recovery and muscle soreness following metabolic or mechanical overload, but little benefit towards functional recovery. There is evidence from one study only that WBC may assist rehabilitation for adhesive capsulitis of the shoulder. There were no adverse events associated with WBC; however, studies did not seem to undertake active surveillance of predefined adverse events. Until further research is available, athletes should remain cognizant that less expensive modes of cryotherapy, such as local ice-pack application or cold-water immersion, offer comparable

  7. Whole body MR in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Piekarek, A.; Sosnowski, P.; Nowicki, A.; Komarnicki, M.

    2009-01-01

    Background: Multiple myeloma is a cancer of plasma cells which leads to bone marrow infiltration. Aim: Whole-body MR is the most sensitive imaging method available to detect multiple myeloma lesions. Ma terial and methods: MR scans were performed in 100 patients with multiple myeloma who were receiving treatment in the Haematology Clinic in Poznan in the years 2005 - 2006. Whole-body MR scans were performed with general coil 1.0 T in STIR sequences and T1 sequences, in coronal and sagittal planes with scanning area covering the head, neck, trunk and the limbs (FOV for specific regions was 36 -48 cm). The bone lesions were classified as focal (monofocal/multifocal lesions), infiltrative, mixed and 'salt and pepper' type. Depending on the size of the lesions the patients were included in one of three groups according to Salmon-Durie Plus classification. Results: Four main types of multiple myeloma were distinguished based on MR scans: focal (48 patients; monofocal in 10 patients), infiltrative (17 patients), mixed type (19 patients) and 'salt and pepper' type (4 patients). The remaining 12 patients had no multiple myeloma lesions in the bone marrow. Additionally, in 18% of patients a soft tissue mass could be observed. According to Salmon-Durie Plus categorisation 27 subjects were classified as having stage I, 16 patients stage and 57 patients stage III disease. In 12% of patients MR data changed the disease staging. Conclusions: WB MR is a sensitive and effective diagnostic method with an important impact on staging and further treatment of multiple myeloma. (authors)

  8. Calibration of the whole body counter at PSI

    International Nuclear Information System (INIS)

    Mayer, Sabine; Boschung, Markus; Fiechtner, Annette; Habegger, Ruedi; Meier, Kilian; Wernli, Christian

    2008-01-01

    At the Paul Scherrer Institut (PSI), measurements with the whole body counter are routinely carried out for occupationally exposed persons and occasionally for individuals of the population suspected of radioactive intake. In total about 400 measurements are performed per year. The whole body counter is based on a p-type high purity germanium (HPGe) coaxial detector mounted above a canvas chair in a shielded small room. The detector is used to detect the presence of radionuclides that emit photons with energies between 50 keV and 2 MeV. The room itself is made of iron from old railway rails to reduce the natural background radiation to 24 n Sv/h. The present paper describes the calibration of the system with the IGOR phantom. Different body sizes are realized by different standardized configurations of polyethylene bricks, in which small tubes of calibration sources can be introduced. The efficiency of the detector was determined for four phantom geometries (P1, P2, P4 and P6 simulating human bodies in sitting position of 12 kg, 24 kg, 70 kg and 110 kg, respectively. The measurements were performed serially using five different radionuclide sources ( 40 K, 60 Co, 133 Ba, 137 Cs, 152 Eu) within the phantom bricks. Based on results of the experiment, an efficiency curve for each configuration and the detection limits for relevant radionuclides were determined. For routine measurements, the efficiency curve obtained with the phantom geometry P4 was chosen. The detection limits range from 40 Bq to 1000 Bq for selected radionuclides applying a measurement time of 7 min. The proper calibration of the system, on one hand, is essential for the routine measurements at PSI. On the other hand, it serves as a benchmark for the already initiated characterisation of the system with Monte Carlo simulations. (author)

  9. National survey of human body radioactivity measured by a mobile whole-body counter and installed whole-body counters

    International Nuclear Information System (INIS)

    Boddy, K.; Fenwick, J.D.; McKenzie, A.L.

    1989-05-01

    Body radioactivity in the general public has been measured in 2339 volunteers throughout the U.K. A mobile whole-body monitor visited collaborating Medical Physics Departments and data were also contributed by Medical Physics Departments possessing installed counters. Levels of body radiocaesium ranged from below detection level to 4149 Bq. Radiocaesium levels were normalised by dividing by the content of natural body potassium-40. In all cases, the dose rate to the body from radiocaesium was less than that from potassium-40. Radiocaesium levels were 2-3 times higher in N.W. England, Scotland and N. Wales than the rest of the country, but this factor is much less than the variation in deposition of Chernobyl radiocaesium. This discrepancy may be accounted for by the nationwide distribution of foodstuffs. At all sites where volunteers were monitored, the ratio of caesium-137/caesium-134 was consistent with a radiocaesium intake attributable primarily to fallout from the Chernobyl fire. (author)

  10. Effectiveness of Different Rest Intervals Following Whole-Body Vibration on Vertical Jump Performance between College Athletes and Recreationally Trained Females

    Directory of Open Access Journals (Sweden)

    Nicole C. Dabbs

    2015-09-01

    Full Text Available The purpose of this study was to evaluate the effect of different rest intervals following whole-body vibration on counter-movement vertical jump performance. Sixteen females, eight recreationally trained and eight varsity athletes volunteered to participate in four testing visits separated by 24 h. Visit one acted as a familiarization visit where subjects were introduced to the counter-movement vertical jump and whole-body vibration protocols. Visits 2–4 contained 2 randomized conditions. Whole-body vibration was administered in four bouts of 30 s with 30 s rest between bouts. During whole-body vibration subjects performed a quarter squat every 5 s, simulating a counter-movement vertical jump. Whole-body vibration was followed by three counter-movement vertical jumps with five different rest intervals between the vibration exposure and jumping. For a control condition, subjects performed squats with no whole-body vibration. There was a significant (p < 0.05 main effect for time for vertical jump height, peak power output, and relative ground reaction forces, where a majority of individuals max jump from all whole-body vibration conditions was greater than the control condition. There were significant (p < 0.05 group differences, showing that varsity athletes had a greater vertical jump height and peak power output compared to recreationally trained females. There were no significant (p > 0.05 group differences for relative ground reaction forces. Practitioners and/or strength and conditioning coaches may utilize whole-body vibration to enhance acute counter-movement vertical jump performance after identifying individuals optimal rest time in order to maximize the potentiating effects.

  11. Chromosomal aberrations in Cynomolgus peripheral lymphocytes during and after fractionated whole-body γ-irradiation

    International Nuclear Information System (INIS)

    Guedeney, G.; Malarbet, J.L.; Doloy, M.T.

    1989-01-01

    Cynomolgus monkeys (Macaca fascicularis) were exposed to fractionated whole-body γ-irradiation at high and low dose rates for 4 or 5 weeks. The time-dependence of chromosomal aberrations was studied in relation to the number of lymphocytes during irradiation and after exposure for periods of up to about 600 days for chromosomal aberrations and 200 days for lymphocyte counts. Additivity of the daily effects on the number of chromosomal aberrations was observed during the exposures. Immediately after the end of the exposures the number of chromosomal aberrations decreased to reach low values. The disappearance of chromosomal aberrations seemed to be related to recovery of the lymphocyte counts. The data presented here emphasize the different kinetic patterns of chromosomal aberrations after fractionated and acute irradiation. (author)

  12. Whole-body counting in the Marshall Islands

    International Nuclear Information System (INIS)

    Sun, L.C.; Clinton, J.; Kaplan, E.; Meinhold, C.B.

    1991-01-01

    In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish 137 Cesium body contents among the Enewetak, Rongelap and Utirik populations. 137 Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. 137 Cs body burdens tended to increase with age for both sexes, and were higher in males. The average 137 Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22±4 μSv. For Utirik, the dose was 33± 3 μSv. Since 1985 the Rongelap people have been self-exiled to Mejatto. Biological elimination should have reduced their dose to virtually zero, and the measured dose was 2±2 μSv. If they had remained on Rongelap Island, the calculated dose would have been 99 μSv, which is about one-third of the background dose. 7 refs., 1 tab

  13. Transient global amnesia following a whole-body cryotherapy session.

    Science.gov (United States)

    Carrard, Justin; Lambert, Anne Chantal; Genné, Daniel

    2017-10-13

    Whole-body cryotherapy (WBC), which consists of a short exposure to very cold and dry air in special 'cryo-chambers', is believed to reduce inflammation and musculoskeletal pain as well as improve athletes' recovery. This is the case of a 63-year-old male, who presented with transient global amnesia (TGA) after undertaking a WBC session. TGA is a clinical syndrome characterised by a sudden onset of anterograde amnesia, sometimes coupled with a retrograde component, lasting up to 24 hours without other neurological deficits. Even though the patient completely recovered, as expected, in 24 hours, this case highlights that WBC is potentially not as risk free as thought to be initially. To conclude, before WBC can be medically recommended, well-conducted studies investigating the possible adverse events are required. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Whole-body cryotherapy: empirical evidence and theoretical perspectives.

    Science.gov (United States)

    Bleakley, Chris M; Bieuzen, François; Davison, Gareth W; Costello, Joseph T

    2014-01-01

    Whole-body cryotherapy (WBC) involves short exposures to air temperatures below -100°C. WBC is increasingly accessible to athletes, and is purported to enhance recovery after exercise and facilitate rehabilitation postinjury. Our objective was to review the efficacy and effectiveness of WBC using empirical evidence from controlled trials. We found ten relevant reports; the majority were based on small numbers of active athletes aged less than 35 years. Although WBC produces a large temperature gradient for tissue cooling, the relatively poor thermal conductivity of air prevents significant subcutaneous and core body cooling. There is weak evidence from controlled studies that WBC enhances antioxidant capacity and parasympathetic reactivation, and alters inflammatory pathways relevant to sports recovery. A series of small randomized studies found WBC offers improvements in subjective recovery and muscle soreness following metabolic or mechanical overload, but little benefit towards functional recovery. There is evidence from one study only that WBC may assist rehabilitation for adhesive capsulitis of the shoulder. There were no adverse events associated with WBC; however, studies did not seem to undertake active surveillance of predefined adverse events. Until further research is available, athletes should remain cognizant that less expensive modes of cryotherapy, such as local ice-pack application or cold-water immersion, offer comparable physiological and clinical effects to WBC.

  15. Whole-body γ-irradiation decelerates rat hepatocyte polyploidization.

    Science.gov (United States)

    Ikhtiar, Adnan M

    2015-07-01

    To characterize hepatocyte polyploidization induced by intermediate dose of γ-ray. Male Wistar strain rats were whole-body irradiated (WBI) with 2 Gy of γ-ray at the age of 1 month, and 5-6 rats were sacrificed monthly at 0-25 months after irradiation. The nuclear DNA content of individual hepatocytes was measured by flow cytometry, then hepatocytes were classified into various ploidy classes. Survival percentage, after exposure up to the end of the study, did not indicate any differences between the irradiated groups and controls. The degree of polyploidization in hepatocytes of irradiated rats, was significantly lower than that for the control after 1 month of exposure, and it continued to be lower after up to 8 months. Thereafter, the degree of polyploidization in the irradiated group slowly returned to the control level when the irradiated rats reached the age of 10 months. Intermediate dose of ionizing radiation, in contrast to high doses, decelerate hepatocyte polyploidization, which may coincides with the hypothesis of the beneficial effects of low doses of ionizing radiation.

  16. Whole-body MRI in children and juveniles

    International Nuclear Information System (INIS)

    Schaefer, J.F.; Kramer, U.

    2011-01-01

    The imaging of systemic disorders without radiation exposure by whole-body MRI (wb-MRI) represents a paradigm shift for pediatric radiology. The reduction of multiple regional examinations, if necessary under sedation, results in a faster treatment start. Modern scanner techniques using automatic table movement and allowing the combination of multiple coil elements and synchronized signal recording with numerous independent receiving channels are the basic prerequisite for high-resolution wb-MRI. The main indications are the evaluation of multifocal bone involvement in different disorders, rheumatic disorders including fever of unknown origin or metastatic spread in solid tumors. Based on the research, there is currently no absolute indication. However, wb-MRI has been shown to yield a higher diagnostic performance than bone scintigraphy and comparable results to FDG-PET for the detection of bone metastases. Due to the low number of published studies, it is uncertain for which entity of solid tumors wb-MRI is the modality of choice and for which tumors wb-MRI will play only a complementary role in the diagnostic work-up. Methodical strategies, pitfalls in image analysis, indications and diagnostic accuracy will be discussed based on already published results as well as our own experience from over 400 examinations, thus providing an overview of the recent research as well as supplying relevant aspects of the daily routine in pediatric wb-MRI. (orig.)

  17. Distribution of transglutaminase family members in mouse whole body sections.

    Science.gov (United States)

    Tatsukawa, Hideki; Abe, Natsumi; Ohashi, Shintaro; Hitomi, Kiyotaka

    2015-11-27

    Transglutaminases (TGs) comprise a protein family in which the members catalyze the formation of isopeptide bonds between glutamine and lysine residues in various proteins. Eight enzymes have been identified and designated as factor XIII (FXIII) and TG1-7. Expression studies of four major members, i.e., FXIII, TG1, TG2, and TG3, have been performed in a relatively large number of mammalian tissues in comparison with those on the other isozymes. The structural and biochemical characteristics of these individual isozymes and expression analyses of TG family in some tissue extracts have been reported, but there have been no simultaneous comparative analyses of both their mRNA and protein expression patterns in tissues distributions. Thus, we developed novel experimental systems for in situ hybridization using cryofilm attached to whole body sections of neonatal mice, thereby obtaining data regarding the tissue distributions of the major TG isozymes. In this study, we performed the first detailed comparative analysis of the mRNA and protein distribution studies of TG family members in a wide range of mouse tissues. These data will be helpful for elucidating the unknown physiological and pathological functions of TGs. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Cryotherapy: local - whole-body; Kryotherapie Lokal - Ganzkoerper

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, R. [Klinik fuer Rheumatologie, St. Josef-Stift Sendenhorst (Germany)

    1994-12-31

    Cryotherapy, whether administered through ice, cold air, nitrogen or cold pack has an effect that can even reach the point of pain elimination. It also acts antiinflammatorily, eases swelling, and improves the function of inflamed joints. Further effects are alleviation of excess muscle tone and maintenance of blood irrigation in inflamed tissue. The fields of indication for cryotherapy can be summarised as follows: inflammation, pain, swelling, functional inhibition, excess muscle tone. Whole-body therapy at -110 C effects significantly enhanced function as compared with a control groups. Blood oxygen rises. Stenocarias have not been reported, whereas extrasystoles are said to decrease. Helper T lymphocytes in the circulating blood drop significantly in rheumatoid arthritis and Bechterev`s disease. This suggests autoimmune disease as a further field of indication. (orig.) [Deutsch] Kryotherapie mit Eis, Kaltluft, Stickstoff, Kaltluft oder Kaeltepackungen wirkt schmerzlindernd bis hin zu Schmerzaufhebung, wirkt entzuendungshemmend, abschwellend und bei Entzuendung funktionsverbessernd in betroffenen Gelenken, Muskeltonuserhoehungen werden abgebaut. Die Durchblutung, wird unter Ryotherapie im Entzuendungsbereich aufrechterhalten. Somit ergeben sich folgende Indikationen: Entzuendung, Schmerz, Schwellung, Funktionseinschraenkung, Muskeltonuserhoehung. Eine Ganzkoerperkaeltetherapie bei -110 C bewirkt eine signifikante Funktionsverbesserung gegenueber einer Kontrollgruppe. Die Sauerstoffkonzentration steigt im Blut. Stenokardien wurden nicht beobachtet. Extrasystolien nahmen ab. T-Helferlymphozyten sinken im zirkulierenden Blut bei Rheumatoider Arthritis und Morbus Bechterew signifikant ab. Daraus erbit sich als weitere Indikation die Behandlung von Autoimmunerkrankungen. (orig.)

  19. Cryotherapy: local - whole-body; Kryotherapie: Lokal - Ganzkoerper

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, R. [Klinik fuer Rheumatologie, St. Josef-Stift, Sendenhorst (Germany)

    1994-12-31

    Cryotherapy, whether administered through ice, cold air, nitrogen, or cold packs has an analgetic effect that can even reach the point of pain elimination. It also inhibits inflammation, relieves swelling, and improves the function of inflamed joints. Further effects are alleviation of excess muscle tone and maintenance of blood irrigation in inflamed tissue. The fields of indication for cryotherapy can be summarised as follows: inflammation, pain, swelling, functional inhibition, excess muscle tone. Whole-body therapy at -110 C effects significantly enhanced function as compared with a control group. Blood oxygen rises. Stenocardias have not been reported, whereas extrasystoles are said to decrease. Helper T lymphocytes in the circulating blood drop significantly in rheumatoid arthritis and Bechterev`s disease. This suggests autoimmune disease as a further field of indication. (orig.) [Deutsch] Kryotherapie mit Eis, Kaltluft, Stickstoff, Kaltluft oder Kaeltepackungen wirkt schmerzlindernd bis hin zur Schmerzaufhebung, wirkt entzuendungshemmend, abschwellend und bei Entzuendung funktionsverbessernd in betroffenen Gelenken. Muskeltonuserhoehungen werden abgebaut. Die Durchblutung wird unter Kryotherapie im Entzuendungsbereich aufrechterhalten. Somit ergeben sich folgende Indikationen: Entzuendung, Schmerz, Schwellung, Funktionseinschraenkung, Muskeltonuserhoehung. Eine Ganzkoerperkaeltetherapie bei -110 C bewirkt eine signifikante Funktionsverbesserung gegenueber einer Kontrollgruppe. Die Sauerstoffkonzentration steigt im Blut. Stenokardien wurden nicht beobachtet. Extrasystolien nahmen ab. T-Helferlymphozyten sinken im zirkulierenden Blut bei Rheumatoider Arthritis und Morbus Bechterew signifikant ab. Daraus ergibt sich als weitere Indikation die Behandlung von Autoimmunerkrankungen. (orig.)

  20. Utilization pattern of whole body computed tomography scanner

    International Nuclear Information System (INIS)

    Youn, Chul Ho; Lee, Sang Suk

    1986-01-01

    Computed tomography scanner (CT scanner) is one of the most expensive and sophisticated diagnostic tool and has already been utilized in many hospitals in Korea. The price as well as operating costs of CT scanner is so expensive as to regulate its installment by government even in the United States. In order to identify the efficient utilization of the CT scanner, the utilization pattern for CT scanning was analyzed at three general hospital in seoul. The results are as follows: 1. Five out of one thousand outpatients and five out of one hundred inpatients were CT scanned. 2. Eighty percent of patients who were scanned were those of inpatients of the hospitals where the scanned are installed. 3. Head standings constitute 45.6 percent of examinations, internal medicine 63.8 percent, and 38.5 percent neurosurgery respectively. 4. The rate of indication for CT scanning showed no statistically significant difference between insured and non-insured groups. 5. Computed tomography scanner units were operated 5.5 days a week in average and full operation rate was 79.5% in average. 6. The major diagnoses mode by head scanning were: hematoma (56.7%), infarction (12.6%), tumor (8.2%), and hydrocephalus (4.4%). 7. Number of patients taken CT Scanning was 43 persons a week in average for each whole body scanner unit

  1. Whole body thermal model of man during hyperthermia

    International Nuclear Information System (INIS)

    Charny, C.K.; Hagmann, M.J.; Levin, R.L.

    1987-01-01

    A whole body thermal model of man has been developed to predict the changes in regional temperatures and blood flows during hyperthermia treatments with the miniannular phased array (MAPA) and annular phased array (APA) applicators. A model of the thermoregulatory response to regional heating based on the experimental and numerical studies of others has been incorporated into this study. Experimentally obtained energy deposition patterns within a human leg exposed to the MAPA were input into the model and the results were compared to those based upon a theoretical deposition pattern. Exposure of the abdomen to the APA was modeled with and without the aberrant energy deposition that has been described previously. Results of the model reveal that therapeutic heating (>42 0 C) of extremity soft tissue sarcomas is possible without significant systemic heating. Very high bone temperatures (>50 0 C) were obtained when the experimental absorption pattern was used. Calculations show that systemic heating due to APA exposure is reduced via evaporative spray cooling techniques coupled with high-velocity ambient air flow

  2. Intraocular lens dislocation after whole-body vibration.

    Science.gov (United States)

    Vela, José I; Andreu, David; Díaz-Cascajosa, Jesús; Buil, José A

    2010-10-01

    We present 2 cases of intraocular lens (IOL) dislocation that appeared shortly after the patients exercised on a vibration platform. The first patient was a 71-year-old woman who presented with lens subluxation in her right eye and a complete posterior IOL dislocation in her left eye. The second case was a 62-year-old woman who presented with unilateral IOL dislocation within the capsular bag in her right eye. Timing from IOL implantation to dislocation was approximately 6 years and 4 years, respectively. Pars plana vitrectomy with removal of the dislocated IOL was performed in both patients. Whole-body vibration training has become increasingly popular as a form of exercise training. It reportedly may provide benefits in physical function and in some diseases, especially in older people. However, evidence-based protocols ensuring safety and efficacy in this population are lacking. We discuss vibration as a cause of late IOL dislocation. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. A whole-body mathematical model for intracranial pressure dynamics.

    Science.gov (United States)

    Lakin, William D; Stevens, Scott A; Tranmer, Bruce I; Penar, Paul L

    2003-04-01

    Most attempts to study intracranial pressure using lumped-parameter models have adopted the classical "Kellie-Monro Doctrine," which considers the intracranial space to be a closed system that is confined within the nearly-rigid skull, conserves mass, and has equal inflow and outflow. The present work revokes this Doctrine and develops a mathematical model for the dynamics of intracranial pressures, volumes, and flows that embeds the intracranial system in extensive whole-body physiology. The new model consistently introduces compartments representing the tissues and vasculature of the extradural portions of the body, including both the thoracic region and the lower extremities. In addition to vascular connections, a spinal-subarachnoid cerebrospinal fluid (CSF) compartment bridges intracranial and extracranial physiology allowing explict buffering of intracranial pressure fluctuations by the spinal theca. The model contains cerebrovascular autoregulation, regulation of systemic vascular pressures by the sympathetic nervous system, regulation of CSF production in the choroid plexus, a lymphatic system, colloid osmotic pressure effects, and realistic descriptions of cardiac output. To validate the model in situations involving normal physiology, the model's response to a realistic pulsatile cardiac output is examined. A well-known experimentally-derived intracranial pressure-volume relationship is recovered by using the model to simulate CSF infusion tests, and the effect on cerebral blood flow of a change in body position is also examined. Cardiac arrest and hemorrhagic shock are simulated to demonstrate the predictive capabilities of the model in pathological conditions.

  4. Reconstruction of a whole-body counter into a process computer-controlled low-level whole-body scanner

    International Nuclear Information System (INIS)

    Hamann, C.

    1975-01-01

    A report is given on the state of the research project to reconstruct our whole-body counter with solid geometries into a scanning type one. The object is to develop a process computer controlled 'adaptive system'. The self-built scan mechanics are explained and the advantages and problems of applying stepping motors are gone into. A stepping motor coordinates control is presented. As the planned scanner and the process computer form a digital controlled system, all theoretical and actual values as well as the control orders from the process computer must be directly controllable. A CAMAC system was not used for economical reasons, the process periphery was made controllable by self building of interfaces to and from the computer. As example, the available multi-channel analyzers were converted to external controlling. The price-moderate and relatively simple self-built set-up are outlined and an example is given of how a TELETYPE version is reconstructed into a fast electronic interface. A BUS-MULTIPLEX system was developed which generates all necessary DI/DO interfaces out of one DI and DO address of the process computer only. The essential part of this system is given. (orig./LH) [de

  5. Contribution of anaerobic energy expenditure to whole body thermogenesis

    Directory of Open Access Journals (Sweden)

    Scott Christopher B

    2005-06-01

    Full Text Available Abstract Heat production serves as the standard measurement for the determination of energy expenditure and efficiency in animals. Estimations of metabolic heat production have traditionally focused on gas exchange (oxygen uptake and carbon dioxide production although direct heat measurements may include an anaerobic component particularly when carbohydrate is oxidized. Stoichiometric interpretations of the ratio of carbon dioxide production to oxygen uptake suggest that both anaerobic and aerobic heat production and, by inference, all energy expenditure – can be accounted for with a measurement of oxygen uptake as 21.1 kJ per liter of oxygen. This manuscript incorporates contemporary bioenergetic interpretations of anaerobic and aerobic ATP turnover to promote the independence of these disparate types of metabolic energy transfer: each has different reactants and products, uses dissimilar enzymes, involves different types of biochemical reactions, takes place in separate cellular compartments, exploits different types of gradients and ultimately each operates with distinct efficiency. The 21.1 kJ per liter of oxygen for carbohydrate oxidation includes a small anaerobic heat component as part of anaerobic energy transfer. Faster rates of ATP turnover that exceed mitochondrial respiration and that are supported by rapid glycolytic phosphorylation with lactate production result in heat production that is independent of oxygen uptake. Simultaneous direct and indirect calorimetry has revealed that this anaerobic heat does not disappear when lactate is later oxidized and so oxygen uptake does not adequately measure anaerobic efficiency or energy expenditure (as was suggested by the "oxygen debt" hypothesis. An estimate of anaerobic energy transfer supplements the measurement of oxygen uptake and may improve the interpretation of whole-body energy expenditure.

  6. Whole body exposure of rats to sulfur mustard vapor.

    Science.gov (United States)

    Dachir, Shlomit; Rabinovitz, Ishai; Yaacov, Guy; Gutman, Hila; Cohen, Liat; Horwitz, Vered; Cohen, Maayan; Kadar, Tamar

    2017-11-24

    Sulfur mustard (SM) is an incapacitating chemical warfare agent used in numerous conflicts around the world and it is still a major threat for both, army troops and civilians. To evaluate its multiple targets effects in experimental setup, a model of whole body exposure (WBE) to SM vapor was established in rats and its simultaneous effects on lungs and eyes as well as on general wellbeing were examined. Rats were exposed to SM vapor. Evaluation (up to 10 weeks post-exposure) included body weight, general observation, blood counts and histological analysis. Results showed that following a latency-period of several hours, rats typical symptoms developed over a period of more than one week. The initial symptoms, characterized by swollen and erythematic nose, deteriorated into extensive rhinorrhea, eye closure, excessive lacrimation as well as rhonchi, wheezing and breathing difficulties. Alopecia and behavioral abnormality were also recorded. A weight loss of up to 40% was measured within one week with spontaneous recovery to baseline level within three weeks after exposure. Blood counts revealed leukopenia during the first three days post-exposure. Histological evaluation revealed a long lasting damage to the trachea, lungs and eyes. Thus, WBE to SM, was found to closely mimic the deleterious effects of SM on the sensitive tissues previously described in human victims during WWI and the Iran-Iraq war. The use of this animal model will enable comprehensive characterization of changes in biological processes that may lead to the development of therapeutic measures to ameliorate SM induced multi-system injuries.

  7. Cerebral autoregulation during whole-body hypothermia and hyperthermia stimulus.

    Science.gov (United States)

    Doering, T J; Aaslid, R; Steuernagel, B; Brix, J; Niederstadt, C; Breull, A; Schneider, B; Fischer, G C

    1999-01-01

    The purpose of the study contained herein was to investigate the effects of old traditional physiotherapeutic treatments on cerebral autoregulation. Treatment consisted of complete body immersion in cold or warm water baths. Fifteen volunteers were investigated by means of transcranial Doppler sonography and a servo-controlled noninvasive device for blood pressure measuring. One group of 8 volunteers (mean age, 27.2+/-3.5 yr; gender, 3 females/5 males) was subjected to cold baths of 22 degrees C for 20 min Another group of 7 volunteers (mean age, 52.1+/-8.5 yr; gender, 4 females/3 males) took hyperthermic baths at rising water temperatures from 36 degrees to 42 degrees C, increased by 1 degree C every 5 min. Each volunteer in both groups underwent autoregulation tests two to four times before, during, and after the thermic bath. Dynamic autoregulation was measured by the response of cerebral blood flow velocity to a transient decrease of the mean arterial blood pressure, induced by rapid deflation of thigh cuffs. The autoregulation index, i.e., a measure of the speed of change of cerebral autoregulation, was used to quantify the response. Further parameters were core temperature, blood pressure (mm Hg) and CO2et. During hypothermic baths, core temperature decreased by 0.3 degrees C (P = 0.001), measured between preliminary phase and the end of the bath; the autoregulation index decreased significantly (P whole-body thermostimulus. Application of hyperthermic baths increased the autoregulation index, and hypothermic baths decreased the autoregulation index. Further studies are needed to prove the positive effects of thermo-stimulating water applications on cerebral hemodynamics in patients with cerebral diseases.

  8. Whole body immersion and hydromineral homeostasis: effect of water temperature.

    Science.gov (United States)

    Jimenez, Chantal; Regnard, Jacques; Robinet, Claude; Mourot, Laurent; Gomez-Merino, Danielle; Chennaoui, Mounir; Jammes, Yves; Dumoulin, Gilles; Desruelle, Anne-Virginie; Melin, Bruno

    2010-01-01

    This experiment was designed to assess the effects of prolonged whole body immersion (WBI) in thermoneutral and cold conditions on plasma volume and hydromineral homeostasis.10 navy "combat swimmers" performed three static 6-h immersions at 34 degrees C (T34), 18 degrees C (T18) and 10 degrees C (T10). Rectal temperature, plasma volume (PV) changes, plasma proteins, plasma and urine ions, plasma osmolality, renin, aldosterone and antidiuretic hormone (ADH) were measured. Results show that compared to pre-immersion levels, PV decreased throughout WBI sessions, the changes being markedly accentuated in cold conditions. At the end of WBI, maximal PV variations were -6.9% at T34, -14.3% at T18, and -16.3% at T10. Plasma osmolality did not change during and after T34 immersion, while hyperosmolality was present at the end of T18 immersion and began after only 1 h of T10 immersion. In the three temperature conditions, significant losses of water (1.6-1.7 l) and salt (6-8 g) occurred and were associated with similar increases in osmolar and free water clearances. Furthermore, T18 and T10 immersions increased the glomerular filtration rate. There was little or no change in plasma renin and ADH, while the plasma level of aldosterone decreased equally in the three temperature conditions. In conclusion, our data indicate that cold water hastened PV changes induced by immersion, and increased the glomerular filtration rate, causing larger accumulated water losses. The iso-osmotic hypovolemia may impede the resumption of baseline fluid balance. Results are very similar to those repeatedly described by various authors during head-out water immersion.

  9. Automatic aortic root segmentation in CTA whole-body dataset

    Science.gov (United States)

    Gao, Xinpei; Kitslaar, Pieter H.; Scholte, Arthur J. H. A.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Reiber, Johan H. C.

    2016-03-01

    Trans-catheter aortic valve replacement (TAVR) is an evolving technique for patients with serious aortic stenosis disease. Typically, in this application a CTA data set is obtained of the patient's arterial system from the subclavian artery to the femoral arteries, to evaluate the quality of the vascular access route and analyze the aortic root to determine if and which prosthesis should be used. In this paper, we concentrate on the automated segmentation of the aortic root. The purpose of this study was to automatically segment the aortic root in computed tomography angiography (CTA) datasets to support TAVR procedures. The method in this study includes 4 major steps. First, the patient's cardiac CTA image was resampled to reduce the computation time. Next, the cardiac CTA image was segmented using an atlas-based approach. The most similar atlas was selected from a total of 8 atlases based on its image similarity to the input CTA image. Third, the aortic root segmentation from the previous step was transferred to the patient's whole-body CTA image by affine registration and refined in the fourth step using a deformable subdivision surface model fitting procedure based on image intensity. The pipeline was applied to 20 patients. The ground truth was created by an analyst who semi-automatically corrected the contours of the automatic method, where necessary. The average Dice similarity index between the segmentations of the automatic method and the ground truth was found to be 0.965±0.024. In conclusion, the current results are very promising.

  10. Polyarteritis nodosa: MDCT as a 'One-Stop Shop' Modality for Whole-Body Arterial Evaluation

    International Nuclear Information System (INIS)

    Tsai, W.-L.; Tsai, I-C.; Lee Tain; Hsieh, C.-W.

    2008-01-01

    Polyarteritis nodosa is a rare disease, which is characterized by aneurysm formation and occlusion in the arteries of multiple systems. Due to its extensive involvement, whole-body evaluation is necessary for diagnosis and treatment monitoring. We report a case of polyarteritis nodosa using multidetector-row computed tomography (MDCT) as a 'one-stop shop' modality for whole-body arterial evaluation. With precise protocol design, MDCT can be used as a reliable noninvasive modality providing comprehensive whole-body arterial evaluation.

  11. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  12. Salivary steroid hormone response to whole-body cryotherapy in elite rugby players.

    Science.gov (United States)

    Grasso, D; Lanteri, P; Di Bernardo, C; Mauri, C; Porcelli, S; Colombini, A; Zani, V; Bonomi, F G; Melegati, G; Banfi, G; Lombardi, G

    2014-01-01

    Saliva represents a low stress, not-invasively collected matrix that allows steroid hormone monitoring in athletes by reflecting type, intensity and duration of exercise. Whole body cryotherapy (WBC) consists of short whole-body exposures to extremely cold air (-110° to -140°C) which, despite being initially used to treat inflammatory diseases, is currently acquiring increasing popularity in sports medicine. Cryostimulation practice is now widely accepted as an effective treatment to accelerate muscle recovery in rugby players. The aim of this work was to study the changes of steroid hormones in saliva of rugby players after both 2 and 14 consecutive WBC sessions, in order to investigate the effects of the treatment on their salivary steroid hormonal profile. Twenty-five professional rugby players, belonging to the Italian National Team, underwent a 7-day cryotherapy protocol consisting of 2 daily sessions. Saliva samples were taken in the morning prior to the start of the WBC, in the evening after the end of the second WBC, and in the morning of the day after the last WBC session. The samples were analyzed for cortisol, DHEA, testosterone and estradiol using competitive enzyme-linked immunosorbent assays. Cortisol and DHEA showed a reduction already after the 2 WBC sessions of the first day; after 14 consecutive WBC sessions cortisol, DHEA, and estradiol levels decreased, while testosterone increased as did the testosterone to cortisol ratio. These results were confirmed by the fact that the majority of subjects showed variations exceeding the critical difference (CD). In conclusion, we found that WBC acutely affects the salivary steroid hormone profile, and the results are evident already after only one twice-daily session. Most significantly, after one-week of consecutive twice-daily WBC sessions, all the hormones were modified. This is the first experimental report that links changes in the hormonal asset to WBC.

  13. A Single Day of Excessive Dietary Fat Intake Reduces Whole-Body Insulin Sensitivity: The Metabolic Consequence of Binge Eating

    Directory of Open Access Journals (Sweden)

    Siôn A. Parry

    2017-07-01

    Full Text Available Consuming excessive amounts of energy as dietary fat for several days or weeks can impair glycemic control and reduce insulin sensitivity in healthy adults. However, individuals who demonstrate binge eating behavior overconsume for much shorter periods of time; the metabolic consequences of such behavior remain unknown. The aim of this study was to determine the effect of a single day of high-fat overfeeding on whole-body insulin sensitivity. Fifteen young, healthy adults underwent an oral glucose tolerance test before and after consuming a high-fat (68% of total energy, high-energy (78% greater than daily requirements diet for one day. Fasting and postprandial plasma concentrations of glucose, insulin, non-esterified fatty acids, and triglyceride were measured and the Matsuda insulin sensitivity index was calculated. One day of high-fat overfeeding increased postprandial glucose area under the curve (AUC by 17.1% (p < 0.0001 and insulin AUC by 16.4% (p = 0.007. Whole-body insulin sensitivity decreased by 28% (p = 0.001. In conclusion, a single day of high-fat, overfeeding impaired whole-body insulin sensitivity in young, healthy adults. This highlights the rapidity with which excessive consumption of calories through high-fat food can impair glucose metabolism, and suggests that acute binge eating may have immediate metabolic health consequences for the individual.

  14. Guidelines for Whole-Body Vibration Health Surveillance

    Science.gov (United States)

    POPE, M.; MAGNUSSON, M.; LUNDSTRÖM, R.; HULSHOF, C.; VERBEEK, J.; BOVENZI, M.

    2002-05-01

    examination, which includes recording any change in exposure to WBV. The findings for the individual should be compared with previous examinations. Group data should also be compiled periodically. Medical removal may be considered along with re-placement in working practices without exposure to WBV. This paper presents opinions on health surveillance for whole-body vibration developed within a working group of partners funded on a European Community Network (BIOMED2 concerted action BMH4-CT98-3251: Research network on detection and prevention of injuries due to occupational vibration exposures). The health surveillance protocol and the draft questionnaire with explanation comments are presented for wider consideration by the science community and others before being considered appropriate for implementation.

  15. The effects of whole body vibration combined biofeedback postural control training on the balance ability and gait ability in stroke patients.

    Science.gov (United States)

    Uhm, Yo-Han; Yang, Dae-Jung

    2017-11-01

    [Purpose] The purpose of this study was to examine the effect of biofeedback postural control training using whole body vibration in acute stroke patients on balance and gait ability. [Subjects and Methods] Thirty stroke patients participated in this study and were divided into a group of 10, a group for biofeedback postural control training combined with a whole body vibration, one for biofeedback postural control training combined with an aero-step, and one for biofeedback postural control training. Biorescue was used to measure the limits of stability, balance ability, and Lukotronic was used to measure step length, gait ability. [Results] In the comparison of balance ability and gait ability between the groups for before and after intervention, Group I showed a significant difference in balance ability and gait ability compared to Groups II and III. [Conclusion] This study showed that biofeedback postural control training using whole body vibration is effective for improving balance ability and gait ability in stroke patients.

  16. The effects of whole body vibration combined computerized postural control training on the lower extremity muscle activity and cerebral cortex activity in stroke patients.

    Science.gov (United States)

    Uhm, Yo-Han; Yang, Dae-Jung

    2018-02-01

    [Purpose] The purpose of this study was to examine the effect of computerized postural control training using whole body vibration on lower limb muscle activity and cerebral cortical activation in acute stroke patients. [Subjects and Methods] Thirty stroke patients participated and were divided into groups of 10, a group of the computerized postural control training using whole body vibration (Group I), the computerized postural control training combined with aero step (Group II) and computerized postural control training (Group III). MP100 was used to measure lower limb muscle activity, and QEEG-8 was used to measure cerebral cortical activation. [Results] Comparison of muscle activity and cerebral cortical activation before and after intervention between groups showed that Group I had significant differences in lower limb muscle activity and cerebral cortical activation compared to Groups II and III. [Conclusion] This study showed that whole body vibration combined computerized postural control training is effective for improving muscle activity and cerebral cortex activity in stroke patients.

  17. Whey Protein Supplementation Enhances Whole Body Protein Metabolism and Performance Recovery after Resistance Exercise: A Double-Blind Crossover Study

    Directory of Open Access Journals (Sweden)

    Daniel W. D. West

    2017-07-01

    Full Text Available No study has concurrently measured changes in free-living whole body protein metabolism and exercise performance during recovery from an acute bout of resistance exercise. We aimed to determine if whey protein ingestion enhances whole body net protein balance and recovery of exercise performance during overnight (10 h and 24 h recovery after whole body resistance exercise in trained men. In a double-blind crossover design, 12 trained men (76 ± 8 kg, 24 ± 4 years old, 14% ± 5% body fat; means ± standard deviation (SD performed resistance exercise in the evening prior to consuming either 25 g of whey protein (PRO; MuscleTech 100% Whey or an energy-matched placebo (CHO immediately post-exercise (0 h, and again the following morning (~10 h of recovery. A third randomized trial, completed by the same participants, involving no exercise and no supplement served as a rested control trial (Rest. Participants ingested [15N]glycine to determine whole body protein kinetics and net protein balance over 10 and 24 h of recovery. Performance was assessed pre-exercise and at 0, 10, and 24 h of recovery using a battery of tests. Net protein balance tended to improve in PRO (P = 0.064; effect size (ES = 0.61, PRO vs. CHO during overnight recovery. Over 24 h, net balance was enhanced in PRO (P = 0.036 but not in CHO (P = 0.84; ES = 0.69, PRO vs. CHO, which was mediated primarily by a reduction in protein breakdown (PRO < CHO; P < 0.01. Exercise decreased repetitions to failure (REP, maximal strength (MVC, peak and mean power, and countermovement jump performance (CMJ at 0 h (all P < 0.05 vs. Pre. At 10 h, there were small-to-moderate effects for enhanced recovery of the MVC (ES = 0.56, mean power (ES = 0.49, and CMJ variables (ES: 0.27–0.49 in PRO. At 24 h, protein supplementation improved MVC (ES = 0.76, REP (ES = 0.44, and peak power (ES = 0.55. In conclusion, whey protein supplementation enhances whole body anabolism, and may improve acute recovery of

  18. Whole body plastination, intra-organ heterogeneity, and tissue based diagnosis – a survey

    Directory of Open Access Journals (Sweden)

    Gunther von Hagens

    2018-04-01

    Full Text Available  Background: The corpse is the final structural relict of life. Its detailed analysis, the autopsy formed the basis and contributed significantly to our understanding of location, function and interaction of organs in man. Today, autopsies are performed rarely. They have been replaced by radiological in vivo visualization techniques and the analysis of organ excisions and biopsies. Which attributes do whole body preservations possess in this context? Techniques of Whole Body Analysis: In vivo imaging transfers the appearance of body organs and cellular structures in virtual images. The patient’s exposure to X-rays, fundamental particles (electrons, positrons, etc., strong magnetic fields (nuclear resonance, or ultra sounds release the corresponding signals. The obtained images are interpreted in search for local abnormalities such as cancer, acute and chronic infections, inborn errors, hypertrophy or atrophy. Autopsies require the removal and visual inspection of organs shortly after the victim’s death. In addition, tissue probes of suspicious lesions are fixed and microscopically analyzed. The search for gene or protein abnormalities are added dependent upon the clinical history and gross findings. The whole body plastination is performed in separated steps which include fixation, anatomical dissection, forced polymer impregnation, positioning and curing. Organs and other tissue structures can be taken out of the body and separately demonstrated, or aligned and fixed within the body. Additional tissue examinations are possible at this stage, which is followed by hardening and fixation of the still flexible body. Fixation is done with heat, light or gas.   Results and Interpretation: Tissue conservation is a prerequisite to analyze and investigate in diagnosis and forecast of disease occurrence and behaviour. In history, autopsies have opened the door to localize the position and to understand the functions of organs. Today, they have been

  19. Melatonin, a potential effective protector in whole body γ-irradiated rats

    International Nuclear Information System (INIS)

    Tawfik, S.S; El-Nashar, D.E; Ahmed, M.M; Hanafy, Z.E

    2010-01-01

    Melatonin (N-acetyl-5-methoxytryptamine), the chief hormone of pineal gland, is widely distributed in animal kingdom. It is claimed for its antioxidant and free radical properties. The present study aimed to examine the radio protective potentiality and efficacy of melatonin against damages induced in whole body γ-irradiated rats. Animals received melatonin (10 mg/ kg body wt/ day) for 10 successive days pre-exposure to 3 Gy of γ-radiation (acute dose). Rats sacrificed at 10 and 20 days post the irradiation time. The results revealed that the prolonged administration of melatonin has ameliorated the radiation- induced depletion in brain, testis and serum glutathione (GSH) level and a decrease in serum glutathione peroxidase (GPX) activity when compared with their matched values in irradiated rats. In addition, remarkable decreases in the concentration of lipid peroxidation (LPO) product; malondialdhyde (MDA) was observed in brain, testis and serum of rats received melatonin pre-radiation exposure. As well as, significant decreases in disulphide glutathione (GSSG) were observed in serum.Histopathological examination of brain and testis showed that administration of melatonin pre-irradiation according to the present regimen has attenuated radiation induced tissue damages and improved tissue architecture. Cytogenetically, the chromosomal aberration (CA) assay in bone marrow pointed out a significant difference between rats received melatonin pre-irradiation and γ-irradiated rats in most CA types. Accordingly, it could be postulated the tissue diversity and cytogenetic impact of the administrated melatonin against acute ion syndrome in rat model.

  20. Made-to-measure pattern development based on 3D whole body scans

    NARCIS (Netherlands)

    Daanen, H.; Hong, S.A.

    2008-01-01

    Purpose - New techniques are required to link 3D whole body scans to manufacturing techniques to allow for the mass-customization of clothes. This study aims to compare two methods of producing skirts based on 3D whole body scans. Design/methodology/approach - Three females participated in the

  1. Oak Ridge National Laboratory whole-body counter: internal operating procedure manual

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.

    1982-08-01

    The general purpose of the ORNL Whole Body Counter is to provide a rapid estimation of the type and quantity of radionuclide deposited in the human body. This report contains a review of the equipment in use at the facility and the procedure for its operation, the standard procedure for performing a routine whole body count, and a discussion of interpretation of results

  2. A high protein diet upregulated whole-body protein turnover during energy deficit

    Science.gov (United States)

    The effects of higher protein diets and sustained energy deficit (ED) on whole-body protein turnover (WBPTO) are not well described. This study examined whether dietary protein level influences whole-body protein breakdown (Ra), non-oxidative leucine disposal (NOLD), and oxidation (Ox) during ED. ...

  3. Segmentation and visual analysis of whole-body mouse skeleton microSPECT

    NARCIS (Netherlands)

    Khmelinskii, A.; Groen, H.C.; De Jong, M.; Lelieveldt, B.P.F.

    2012-01-01

    Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality,

  4. Segmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT

    NARCIS (Netherlands)

    A. Khmelinskii (Artem); H.C. Groen (Harald); M. Baiker (Martin); M. de Jong (Marion); B.P.F. Lelieveldt (Boudewijn)

    2012-01-01

    textabstractWhole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput,

  5. [The effect of betahistine on histological changes in rabbit brain in model of whole body wide-frequency vibration].

    Science.gov (United States)

    Shimkus, Iu Iu; Sapegin, I D

    2013-01-01

    In acute experiments in conscious rabbits was studied protective action of selective blocker of histamine H3-receptor betahistine (2mg/kg i/v) against histological changes in precentral and postcentral gyrus, as well as in temporal lobe of cerebral cortex, thalamus, hypothalamus, and cerebellum, arising in case of modeling of whole body wide-frequency vibration. Betahistine attenuates edematous and degenerative changes in neurons and reciprocal glial reaction, caused by vibration, but does not eliminate edema in perivascular spaces. This effect may be related to the improvement of blood supply as a result of of vasodilatory action and decrease of oxygen consumption via vestibuloprotective effect.

  6. A DXA Whole Body Composition Cross-Calibration Experience: Evaluation With Humans, Spine, and Whole Body Phantoms.

    Science.gov (United States)

    Krueger, Diane; Libber, Jessie; Sanfilippo, Jennifer; Yu, Hui Jing; Horvath, Blaine; Miller, Colin G; Binkley, Neil

    2016-01-01

    substantial lean and fat differences observed using BBCP and in vivo assessments. Consequently, spine phantoms are inadequate for dual-energy X-ray absorptiometry whole body composition cross-calibration. Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  7. WHOLE BODY VIBRATION IMPROVES ATTENTION AND MOTOR PERFORMANCE IN MICE DEPENDING ON THE DURATION OF THE WHOLE-BODY VIBRATION SESSION.

    Science.gov (United States)

    Keijser, Jan N; van Heuvelen, Marieke J G; Nyakas, Csaba; Tóth, Kata; Schoemaker, Regien G; Zeinstra, Edzard; van der Zee, Eddy A

    2017-01-01

    Whole body vibration (WBV) is a form of physical stimulation via mechanical vibrations transmitted to a subject. It is assumed that WBV induces sensory stimulation in cortical brain regions through the activation of skin and muscle receptors responding to the vibration. The effects of WBV on muscle strength are well described. However, little is known about the impact of WBV on the brain. Recently, it was shown in humans that WBV improves attention in an acute WBV protocol. Preclinical research is needed to unravel the underlying brain mechanism. As a first step, we examined whether chronic WBV improves attention in mice. A custom made vibrating platform for mice with low intensity vibrations was used. Male CD1 mice (3 months of age) received five weeks WBV (30 Hz; 1.9 G), five days a week with sessions of five (n=12) or 30 (n=10) minutes. Control mice (pseudo-WBV; n=12 and 10 for the five and 30 minute sessions, respectively) were treated in a similar way, but did not receive the actual vibration. Object recognition tasks were used as an attention test (novel and spatial object recognition - the primary outcome measure). A Balance beam was used for motor performance, serving as a secondary outcome measure. WBV sessions of five (but not WBV sessions of 30 minutes) improved balance beam performance (mice gained 28% in time needed to cross the beam) and novel object recognition (mice paid significantly more attention to the novel object) as compared to pseudo WBV, but no change was found for spatial object performance (mice did not notice the relocation). Although 30 minutes WBV sessions were not beneficial, it did not impair either attention or motor performance. These results show that brief sessions of WBV improve, next to motor performance, attention for object recognition, but not spatial cues of the objects. The selective improvement of attention in mice opens the avenue to unravel the underlying brain mechanisms.

  8. Effects of quadriceps strength after static and dynamic whole-body vibration exercise.

    Science.gov (United States)

    Bush, Jill A; Blog, Gabriel L; Kang, Jie; Faigenbaum, Avery D; Ratamess, Nicholas A

    2015-05-01

    Numerous studies have shown performance benefits including whole-body vibration (WBV) as a training modality or an acute exercise protocol when used as a component of the resistance training program. Some studies have indicated that performing dynamic exercises as compared with static position exercises while exposed to WBV might be beneficial; however, evidence is lacking. Thus, the purpose of this study was to determine if an acute bout of dynamic versus static squats performed during WBV results in increase in quadriceps force production by means of dynamic isokinetic knee extension and flexion exercise. Nonresistance-trained healthy young men and women (N = 21) of 18-25 years participated in 4 protocols with 2-week rest in-between. Protocol 1 consisted of 5 sets of 10 dynamic squats without vibration; Protocol 2: 5 sets of 30-second static squats without vibration; Protocol 3: 5 sets of 10 dynamic squats with 30-Hz WBV for a total of 2.5 minutes; and Protocol 4: 5 sets of 30-second static squats with 30-Hz WBV for a total of 2.5 minutes. Prestrength tests (1 set of 4 repetitions at 100° · s(-1) for the knee extension exercise) was performed within 5 minutes of starting each protocol, and poststrength testing was performed within 1 minute of completing each protocol. Strength outcomes were analyzed by repeated measures analysis of variance with a significance level set at p ≤ 0.05. A significant decrease in strength was observed after dynamic and static squats without WBV (p = 0.002); an increase in strength after dynamic squats with WBV (p = 0.003); and a decrease in strength after static squats with WBV (p = 0.003). The inclusion of WBV to dynamic resistance exercise can be an added modality to increase strength. Whole-body vibration can have varied effects in altering muscle strength in untrained individuals according to the type of resistance training performed. As a dynamic squat with WBV seems to immediately potentiate neuromuscular functioning, the

  9. Effects of adding whole body vibration to squat training on isometric force/time characteristics.

    Science.gov (United States)

    Lamont, Hugh S; Cramer, Joel T; Bemben, Debra A; Shehab, Randa L; Anderson, Mark A; Bemben, Michael G

    2010-01-01

    Resistance training interventions aimed at increasing lower-body power and rates of force development have produced varying results. Recent studies have suggested that whole-body low-frequency vibration (WBLFV) may elicit an acute postactivation potentiation response, leading to acute improvements in power and force development. Potentially, the use of WBLFV between sets of resistance training rather than during training itself may lead to increased recruitment and synchronization of high-threshold motor units, minimize fatigue potential, and facilitate the chronic adaptation to resistance exercise. The purpose of this study was to determine the effects of applying TriPlaner, WBLFV, prior to and then intermittently between sets of Smith machine squats on short-term adaptations in explosive isometric force expression. Thirty recreationally resistance trained men aged 18-30 were randomly assigned to 1 of 3 groups: resistance training only (SQT, n = 11), resistance plus whole-body vibration (SQTV, n = 13), or active control (CON, n = 6). An isometric squat test was performed prior to and following a 6-week periodized Smith machine squat program. Whole-body low-frequency vibration was applied 180 seconds prior to the first work set (50 Hz, 2-4 mm, 30 seconds) and intermittently (50 Hz, 4-6 mm, 3 x 10 seconds, 60 seconds between exposures) within a 240-second interset rest period. Subjects were instructed to assume a quarter squat posture while positioning their feet directly under their center of mass, which was modified using a handheld goniometer to a knee angle of 135 +/- 5 degrees . Instructions were given to subjects to apply force as fast and as hard as possible for 3.5 seconds. Isometric force (N) and rates of force development (N.s(-1)) were recorded from the onset of contraction (F(0)) to time points corresponding to 30, 50, 80, 100, 150, and 250 milliseconds, as well as the peak isometric rate of force development (PISORFD), and rate of force development to

  10. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  11. Standardization of calibration method of whole-body counter. 1. Calibration by using anthropometric phantoms

    International Nuclear Information System (INIS)

    Ishikawa, Tetsuo; Matsumoto, Masaki; Uchiyama, Masafumi; Kobayashi, Sadayoshi; Mizushita, Seiichi.

    1995-01-01

    To standardize the calibration methods of whole-body counters, three anthropometric phantoms were manufactured based on dozens of Japanese average value of body size data. Using these phantoms, the calibrations of some whole-body counters were carried out and the comparison of counting efficiency between anthropometric phantoms and block phantoms, which used to be used for the calibration of whole-body counters generally, was implemented. Five whole-body counters, one scanning system, two stationary systems and two chair systems, were used for this study. The following results were derived: As an example, in NIRS scanning system, the counting efficiency of anthropometric phantom of 162cm height was 12.7% greater than that of block phantom of the same height. This means 137 Cs body burdens in adult men used to be estimated with the excess of about 10%. Body burdens tended to be estimated excessively in adult because the difference of counting efficiency between anthropometric phantom and block phantom increases with increase of height. To standardize body burden data measured with various whole-body counters, the calibration of each whole-body counter should be conducted using anthropometric phantoms and phantoms which used to be used for the calibration of that whole-body counter. (author)

  12. Preleukemic change in the bone marrow of whole-body irradiated RFM/Up mice

    International Nuclear Information System (INIS)

    Ludwig, F.C.; Schug, W.G.; Bostick, W.L.; Smoke, M.E.

    1977-01-01

    In the whole-body irradiated mouse, various late effects of radiation are observed after the recovery from acute radiation injury. Some of these account for the familiar proneness of certain mouse strains to develop leukemias. The two experiments described below were designed to identify such preleukemic changes in blood-forming tissues and to find ways to manipulate them experimentally with the purpose of preventing leukemia. Preleukemic change of the bone marrow appears to be a mere quantitative departure from normal in a qualitatively non-malignant tissue. It entails increased proneness of immature cells to react with latent virus. The data, received are consistent with the assumption that this prononess is enhanced (or brought about) by removal of a controlling influence exerted by the mature cells over their precursors. Re-irradiation combined with intravenous bone marrow substitution offsets the leukemogenic influence of an earlier radiation exposure. The effect of re-irradiation on bone marrow displaying preleukemic lesions corroborates conclusions from earlier experiments on the nature of these lesions. (orig./MG) [de

  13. Immediate effects of whole body vibration on patellar tendon properties and knee extension torque.

    Science.gov (United States)

    Rieder, F; Wiesinger, H-P; Kösters, A; Müller, E; Seynnes, O R

    2016-03-01

    Reports about the immediate effects of whole body vibration (WBV) exposure upon torque production capacity are inconsistent. However, the changes in the torque-angle relationship observed by some authors after WBV may hinder the measurement of torque changes at a given angle. Acute changes in tendon mechanical properties do occur after certain types of exercise but this hypothesis has never been tested after a bout of WBV. The purpose of the present study was to investigate whether tendon compliance is altered immediately after WBV, effectively shifting the optimal angle of peak torque towards longer muscle length. Twenty-eight subjects were randomly assigned to either a WBV (n = 14) or a squatting control group (n = 14). Patellar tendon CSA, stiffness and Young's modulus and knee extension torque-angle relationship were measured using ultrasonography and dynamometry 1 day before and directly after the intervention. Tendon CSA was additionally measured 24 h after the intervention to check for possible delayed onset of swelling. The vibration intervention had no effects on patellar tendon CSA, stiffness and Young's modulus or the torque-angle relationship. Peak torque was produced at ~70° knee angle in both groups at pre- and post-test. Additionally, the knee extension torque globally remained unaffected with the exception of a small (-6%) reduction in isometric torque at a joint angle of 60°. The present results indicate that a single bout of vibration exposure does not substantially alter patellar tendon properties or the torque-angle relationship of knee extensors.

  14. Whole-body vibration does not influence knee joint neuromuscular function or proprioception.

    Science.gov (United States)

    Hannah, R; Minshull, C; Folland, J P

    2013-02-01

    This study examined the acute effects of whole-body vibration (WBV) on knee joint position sense and indices of neuromuscular function, specifically strength, electromechanical delay and the rate of force development. Electromyography and electrically evoked contractions were used to investigate neural and contractile responses to WBV. Fourteen healthy males completed two treatment conditions on separate occasions: (1) 5 × 1 min of unilateral isometric squat exercise on a synchronous vibrating platform [30 Hz, 4 mm peak-to-peak amplitude] (WBV) and (2) a control condition (CON) of the same exercise without WBV. Knee joint position sense (joint angle replication task) and quadriceps neuromuscular function were assessed pre-, immediately-post and 1 h post-exercise. During maximum voluntary knee extensions, the peak force (PF(V)), electromechanical delay (EMD(V)), rate of force development (RFD(V)) and EMG of the quadriceps were measured. Twitch contractions of the knee extensors were electrically evoked to assess EMD(E) and RFD(E). The results showed no influence of WBV on knee joint position, EMD(V), PF(V) and RFD(V) during the initial 50, 100 or 150 ms of contraction. Similarly, electrically evoked neuromuscular function and neural activation remained unchanged following the vibration exercise. A single session of unilateral WBV did not influence any indices of thigh muscle neuromuscular performance or knee joint proprioception. © 2011 John Wiley & Sons A/S.

  15. Changes in rat plasma fibrinolytic factors during long term follow up after whole body irradiation

    International Nuclear Information System (INIS)

    Dudek-Wojciechowska, G.; Dancewicz, A.M.

    1989-01-01

    Rats were whole body irradiated with a dose of 7.0 Gy and then bled at different times after exposure, from 1 day to 12 months; in their plasma the activity of plasmin, the level of plasminogen, the activity of plasminogen activator as well as α 2 -antiplasmin and α 2 -macroglobulin were determined. In comparison to control values obtained in parallel determinations it was found that during the acute phase of radiation disease (up to 30 days after irradiation) the activity of plasmin and the level of plasminogen underwent fluctuation: at the beginning there was an increase, followed by a decrease at later time intervals. There was also a distinct decrease (over 50%) in the activity of plasminogen activator. During the 2 to 4 weeks after exposure the activity of inhibitors was somewhat decreased, especially that of α 2 -macroglobulin. At later periods the level of plasminogen and the activity of plasminogen activator returned to normal but that of plasmin underwent fluctuation again, reaching a significant decrease in activity 6 and 12 months after exposure. At these time points also some decrease in activity of inhibitors was observed, especially in that of α 2 -macroglobulin. 11 refs., 1 fig., 2 tabs. (author)

  16. Evaluation of /sup 111/In leukocyte whole body scanning

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-11-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with /sup 111/In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes.

  17. Evaluation of 111In leukocyte whole body scanning

    International Nuclear Information System (INIS)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-01-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with 111 In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes

  18. Conjugate whole-body scanning system for quantitative measurement of organ distribution in vivo

    International Nuclear Information System (INIS)

    Tsui, B.M.W.; Chen, C.T.; Yasillo, N.J.; Ortega, C.J.; Charleston, D.B.; Lathrop, K.A.

    1979-01-01

    The determination of accurate, quantitative, biokinetic distribution of an internally dispersed radionuclide in humans is important in making realistic radiation absorbed dose estimates, studying biochemical transformations in health and disease, and developing clinical procedures indicative of abnormal functions. In order to collect these data, a whole-body imaging system is required which provides both adequate spatial resolution and some means of absolute quantitation. Based on these considerations, a new whole-body scanning system has been designed and constructed that employs the conjugate counting technique. The conjugate whole-body scanning system provides an efficient and accurate means of collecting absolute quantitative organ distribution data of radioactivity in vivo

  19. Changes in melatonin in epiphysis after whole-body irradiation of rats with gamma rays

    International Nuclear Information System (INIS)

    Ahlersova, E.; Kassayova, M.; Ahlers, I.

    1998-01-01

    Male Wistar rats were exposed to a whole-body gamma dose of 14.4 or 9.6 Gy in darkness. Other groups were exposed to fractionated irradiation with 2.4 Gy twice a week up to 9.6 and 14.4 Gy. At 30 and 60 min after acute lethal irradiation, a decrease in the melatonin (Mel) concentration in the epiphysis was observed; the activity of N-acetyltransferase (NAT) did not differ from that in the control group. Later, signs of increased synthesis of Mel were observed. NAT activity and Mel concentration in the serum increased on day 3 following exposure to 14.4 Gy. Concentration of Mel in epiphysis and serum increased 5 days after exposure to 9.6 Gy. Fractionated irradiation up to 9.6 Gy brought about a decrease in NAT activity 6 h after exposure, without changes in Mel in epiphysis. In rats with an accumulated dose of 14.4 Gy, NAT activity and Mel concentration in epiphysis (serum) decreased 6 h and 3 days, respectively, after exposure, and monoaminooxidase (MAO) increased appreciably on day 3. On day 5, the enzyme activities and Mel concentrations did not differ from those in the control group. Fractionated irradiation up to 14.4 Gy brought about temporary decrease in the synthesis of Mel in epiphysis, which may be due to preferential oxidative deamination of serotonin as compared to its N-acetylation leading to the synthesis of melatonin. The temporary decrease in the Mel concentration in epiphysis in 60 min after single-dose exposure to 14.4 or 9.6 Gy may be a result of similar metabolic changes. The increased synthesis of Mel in epiphysis at a later stage following acute lethal exposure is seen as an adaptive effort of the organism to produce a sufficient amount of hormone with an antioxidative, antistress and immunomodulative effect

  20. Calculation of effective dose in whole body in dependence of angle of collimator for photon fields

    International Nuclear Information System (INIS)

    Fuenzalida, M.; Varon, C.; Piriz, G.; Banguero, Y.; Lozano, E.; Mancilla, C.

    2011-01-01

    The objective of this work is to obtain quantifiable data of whole body effective dose for photons fields of 6 MV and 18 MV in function of the collimator angle of a Varian Clinac 21EX lineal accelerator. It has been made a variety of studies which investigate the form to reduce the dose in whole body with photons fields, specially over the potential risks and the influence of the collimator angle, as performed Stanthakis et al. [1] with the Monte Carlo method. As a result of this work, the values of whole body effective doses are higher with a 0 deg collimator than with a 90 deg collimator, and as the field size increases, the effective doses difference in whole body, between 0 deg and 90 deg collimator angle, for both energies, becomes smaller. (author)

  1. Whole-Body MRI versus PET in assessment of multiple myeloma disease activity.

    LENUS (Irish Health Repository)

    Shortt, Conor P

    2009-04-01

    The purpose of this study was to compare FDG PET; whole-body MRI; and the reference standard, bone marrow aspiration and biopsy, to determine the best imaging technique for assessment of disease activity in multiple myeloma.

  2. Various performance-enhancing effects from the same intensity of whole-body vibration training

    Directory of Open Access Journals (Sweden)

    Paohung Chung

    2017-09-01

    Conclusion: All frequency and amplitude settings in the 8-week whole-body vibration training increased muscle strength, but different settings resulted in various neuromuscular adaptations despite the same intensity.

  3. Improvement of measuring techniques with whole-body and partial-body counters

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    Mathematical simulation methods have been applied for optimizing and standardizing the calibration of whole-body and partial-body counters for any nuclide accumulation in the human body. (orig./CB) [de

  4. Direct molecular analysis of whole-body animal tissue sections by MALDI imaging mass spectrometry.

    Science.gov (United States)

    Reyzer, Michelle L; Chaurand, Pierre; Angel, Peggi M; Caprioli, Richard M

    2010-01-01

    The determination of the localization of various compounds in a whole animal is valuable for many applications, including pharmaceutical absorption, distribution, metabolism, and excretion (ADME) studies and biomarker discovery. Imaging mass spectrometry is a powerful tool for localizing compounds of biological interest with molecular specificity and relatively high resolution. Utilizing imaging mass spectrometry for whole-body animal sections offers considerable analytical advantages compared to traditional methods, such as whole-body autoradiography, but the experiment is not straightforward. This chapter addresses the advantages and unique challenges that the application of imaging mass spectrometry to whole-body animal sections entails, including discussions of sample preparation, matrix application, signal normalization, and image generation. Lipid and protein images obtained from whole-body tissue sections of mouse pups are presented along with detailed protocols for the experiments.

  5. Signal Processing Methods for Removing the Effects of Whole Body Vibration upon Speech

    Science.gov (United States)

    Bitner, Rachel M.; Begault, Durand R.

    2014-01-01

    Humans may be exposed to whole-body vibration in environments where clear speech communications are crucial, particularly during the launch phases of space flight and in high-performance aircraft. Prior research has shown that high levels of vibration cause a decrease in speech intelligibility. However, the effects of whole-body vibration upon speech are not well understood, and no attempt has been made to restore speech distorted by whole-body vibration. In this paper, a model for speech under whole-body vibration is proposed and a method to remove its effect is described. The method described reduces the perceptual effects of vibration, yields higher ASR accuracy scores, and may significantly improve intelligibility. Possible applications include incorporation within communication systems to improve radio-communication systems in environments such a spaceflight, aviation, or off-road vehicle operations.

  6. Calculation of effective dose in whole body in dependence of angle of collimator for photon fields

    Energy Technology Data Exchange (ETDEWEB)

    Fuenzalida, M. [Universidad de la Frontera, Temuco (Chile). Programa de Magister en Fisica Medica; Varon, C.; Piriz, G.; Banguero, Y.; Lozano, E.; Mancilla, C., E-mail: fisicamedica@incancer.c [Instituto Nacional del Cancer, Santiago (Chile). Unidad de Fisica Medica

    2011-07-01

    The objective of this work is to obtain quantifiable data of whole body effective dose for photons fields of 6 MV and 18 MV in function of the collimator angle of a Varian Clinac 21EX lineal accelerator. It has been made a variety of studies which investigate the form to reduce the dose in whole body with photons fields, specially over the potential risks and the influence of the collimator angle, as performed Stanthakis et al. [1] with the Monte Carlo method. As a result of this work, the values of whole body effective doses are higher with a 0 deg collimator than with a 90 deg collimator, and as the field size increases, the effective doses difference in whole body, between 0 deg and 90 deg collimator angle, for both energies, becomes smaller. (author)

  7. Whole-body MR imaging for patients with rheumatism

    Energy Technology Data Exchange (ETDEWEB)

    Weckbach, Sabine [Department of Clinical Radiology and Nuclear Medicine, Unversity Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany)], E-mail: sabine.weckbach@umm.de

    2009-06-15

    WB-MRI in rheumatic diseases is still an emerging imaging tool. So far, WB-MRI in rheumatism is mainly used in seronegative spondyloarthropathies. In these diseases it has the ability to visualize the majority of involved joints and soft tissue structures (both active inflammatory changes and chronic structural abnormalities) in one examination, making it suitable for imaging of different forms of spondylopathies, allowing different types of joint involvement to be recognized and assessing both the acute symptoms of disease and the longer-term consequences. Its role in daily practice is not yet clear. WB-MRI is not recommended as a first line investigation in every patient suffering from a form of spondyloarthropathy, but may add important information in difficult cases. Moreover, WB-MRI might obtain a stronger role in the early diagnosis of spondyloarthritides and in the assessment of treatment response. Other rheumatic diseases where WB-MRI may play a role in the future are polymyositis/dermatomyositis, CRMO and certain forms of systemic vasculitis. WB-MRI in rheumatism is a promising tool with great potential, however further systematic evaluation of its abilities and limitations in different forms of rheumatic diseases is awaited.

  8. Multiple whole body hyperthermia treatments on normal beagles

    International Nuclear Information System (INIS)

    Geist, B.J.; Gillette, E.L.; Tucker, A.; Robertshaw, D.; Benjamin, S.A.; Macy, D.W.

    1985-01-01

    Twelve young adult male castrated beagles were randomized into either a treatment or a control group. The treatment group received 4 consecutive treatments at 1 week intertreatment intervals. A temperature and humidity controlled chamber was used to raise the core temperature to 42 0 C. Time required to raise the core temperature from 38 0 C to 42 0 C was approximately 70 minutes. Dogs were maintained at 42 0 C breathing halothane, 35% O/sub 2/ and 65 0 N/sub 2/ for 2 hours, followed by a 30 minute cool down period during which a shunt determination using 100% O/sub 2/ was done. No significant changes in temperature adjusted blood oxygen tension were noted during hyperthermia. Mean arterial blood pressure dropped an average of 15mm Hg during the 2 hour plateau. Cardiac rhythms remained stable and rates did not exceed 180 beats per minute. Central venous pressure remained stable and within normal range without treatment, 1.0 - 2.5 mm Hg. Dogs regained alertness and ambulation within 3 hours post treatment. No diarrhea was noted. The most significant acute changes appeared to be liver enzyme elevation, total protein decrement and transient changes in platelet and white blood cell counts

  9. Whole-body MR imaging for patients with rheumatism

    International Nuclear Information System (INIS)

    Weckbach, Sabine

    2009-01-01

    WB-MRI in rheumatic diseases is still an emerging imaging tool. So far, WB-MRI in rheumatism is mainly used in seronegative spondyloarthropathies. In these diseases it has the ability to visualize the majority of involved joints and soft tissue structures (both active inflammatory changes and chronic structural abnormalities) in one examination, making it suitable for imaging of different forms of spondylopathies, allowing different types of joint involvement to be recognized and assessing both the acute symptoms of disease and the longer-term consequences. Its role in daily practice is not yet clear. WB-MRI is not recommended as a first line investigation in every patient suffering from a form of spondyloarthropathy, but may add important information in difficult cases. Moreover, WB-MRI might obtain a stronger role in the early diagnosis of spondyloarthritides and in the assessment of treatment response. Other rheumatic diseases where WB-MRI may play a role in the future are polymyositis/dermatomyositis, CRMO and certain forms of systemic vasculitis. WB-MRI in rheumatism is a promising tool with great potential, however further systematic evaluation of its abilities and limitations in different forms of rheumatic diseases is awaited.

  10. Radiation induced late delayed alterations in mice brain after whole body and cranial radiation: a comparative DTI analysis

    International Nuclear Information System (INIS)

    Watve, Apurva; Gupta, Mamta; Trivedi, Richa; Khushu, Subash; Rana, Poonam

    2016-01-01

    Moderate dose of radiation exposure occurs during radiation accidents or radiation therapy induces pathophysiological alterations in CNS that may persist for longer duration. Studies suggest that late delayed injury is irreversible leading to metabolic and cognitive impairment. Our earlier studies have illustrated the varied response of brain at acute and early delayed phase on exposure to cranial and whole body radiation. Hence in continuation with our previous studies, present study focuses on comparative microstructural changes in brain at late delayed phase of radiation injury using Diffusion Tensor Imaging (DTI) technique. Region of interest (ROIs) were drawn on corpus callosum (CC), hippocampus (HIP), sensory-motor cortex (SMC), thalamus (TH), hypothalamus (HTH), cingulum (CG), caudeto-putamen (CUP) and cerebral peduncle (CP). The differences in FA (Fractional Anisotropy) and MD (Mean Diffusivity) values generated from these regions of all the groups were evaluated by ANOVA with multiple comparisons using Bonferroni, Post Hoc test. Maximum changes have been observed in MD values mainly in cranial group showing significantly increased MD in CC and SMC region while both the groups showed changes in TH and CUP region as compared to control. FA showed more prominent changes in whole body radiation group than cranial group by decreasing significantly in CP region while in HTH and CUP region in both the groups. Reduced FA indicates compromised structural integrity due to the loss of glial progenitor cells causing transient demyelination while increased MD has been equated with cellular membrane disruption, cell death and vasogenic edema. Thus, present study reveals late delayed CNS response after cranial and whole body radiation exposure. These findings can help us differentiate and monitor the pathophysiological changes at later stages either due to accidental or intentional exposure to ionizing radiation

  11. [Application of GVF snake model in segmentation of whole body bone SPECT image].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2008-02-01

    Limited by the imaging principle of whole body bone SPECT image, the gray value of bladder area is quite high, which affects the image's brightness, contrast and readability. In the meantime, the similarity between bladder area and focus makes it difficult for some images to be segmented automatically. In this paper, an improved Snake model, GVF Snake, is adopted to automatically segment bladder area, preparing for further processing of whole body bone SPECT images.

  12. Estimating the whole-body exposure annual dose of radiation workers of petroleum nuclear well logging

    International Nuclear Information System (INIS)

    Tian Yizong; Gao Jianzheng; Liu Wenhong

    2006-01-01

    Objective: By imitating experiment of radioactive sources being installed, to estimate the annual whole-body exposure dose of radiation workers of petroleum nuclear determining wells; Methods: To compre the values of the theory, imitating experiment and γ individual dose monitor calculations. Results: The three values measured above tally with one anather. Conclusion: The annual whole-body exposure doses of radiation workers of petroleum nuclear determining wells are no more than 5 mSv. (authors)

  13. Experience with a mobile whole body counting screening program at Ontario Hydro

    International Nuclear Information System (INIS)

    Wong, K.Y.

    1976-01-01

    A whole-body counting program using a trailer-mounted counter has been in service in Ontario Hydro since 1972 to monitor routinely internal uptakes of radionuclides by nuclear station employees. The philosophy and objectives of the program are discussed; equipment and calibration procedures are described, and experience over the past two and a half years is reviewed. The procedures to minimize the effects of external contamination, a problem commonly encountered in whole-body counting, are described. (auth)

  14. Effect of meal and propranolol on whole body and splanchnic oxygen consumption in patients with cirrhosis

    DEFF Research Database (Denmark)

    Krag, Aleksander; Simonsen, Lene; Henriksen, Jens H

    2006-01-01

    Our aim was to measure whole body energy expenditure after a mixed liquid meal, with and without simultaneous propranolol infusion, in patients with cirrhosis. We also wanted to investigate the effect of propranolol on substrate fluxes and oxygen uptake in the tissues drained by the hepatic vein ...... as splanchnic oxygen uptake. The splanchnic reduction in oxygen consumption can explain almost the entire reduction in whole body oxygen consumption....

  15. Whole-body irradiation in case of malignant lymphomas of low malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Labedzki, L; Schmidt, R E; Hartlapp, J H; Illiger, H J; Frommhold, H; Boldt, I

    1982-04-01

    27 consecutive patients with malignant lymphomas were submittet to whole-body irradiations with doses of 0.5 to 3 Gy. Among these patients ten had been treated before. There were two complete and 16 partial remissions. The condition of five patients could not be considerably improved. Four patients showed a tumor progression during the time of bone marrow depression. The remission period was 11.5 (3 to 22 +) months. The hematologic side effects were considerable; in ten cases, the whole-body irradiation could not be continued because of a thrombocytopenia or an aplastic syndrome. A remarkable fact was the appearance of symptoms similar to that of lupus erythematodes in two patients. An inefficacy of whole-body irradiation did not exclude a response to subsequent chemotherapy. Our own experiences allow to make the following conclusion: in most of all patients with malignant lymphomas of low malignancy a measurable tumor reduction is achieved by whole-body irradiation. Because of the hematologic side effects a whole-body irradiation should be applied only in cases of malignant lymphomas of low malignancy the slow growth of which is proved by observation and which have not been treated before. The thrombocyte numbers should be above 100 000/..mu..l before therapy. Otherwise, the whole-body irradiation has to be stopped before the intended effective dose is reached because of an inevitably developing thrombocytopenia. A whole-body irradiation in case of a malignant lymphoma of low grade malignancy necessitates strict follow-up examinations conducted at regular intervals for a period of at least six weeks after the irradiation. The whole-body irradiation should never be applied as ultima ratio.

  16. Comparison of whole body MR diffusion weighted imaging and skeletal scintigraphy in detecting bone metastasis

    International Nuclear Information System (INIS)

    Xu Xian; Ma Lin; Zhang Jinshan; Cai Youquan; Cheng Liuquan; Guo Xinggao; Xu Baixuan

    2008-01-01

    Objective: To evaluate the application of whole body MR diffusion weighted imaging (DWI) in the detection of bone metastasis using skeletal scintigraphy as the reference. Methods: Forty-two healthy volunteers and 38 patients with malignant tumors were enrolled in our study. All the patients received MR examination and skeletal scintigraphy within one week. MR examination was performed on GE signa 3.0T MR scanner using a build-in body coil. The skeletal system was divided into eight regions and the images of the whole body MR DWI and skeletal scintigraphy were reviewed to compare the two modalities patient by patient and region by region. The images were reviewed separately by two radiologists and two nuclear medicine physicians, who were blinded to the results of another imaging modality. Results: A total of 169 metastatic lesions in 69 regions of 30 patients were detected by whole body MR DWI while 156 lesions in 68 regions of 29 patients were identified by skeletal scintigraphy. There were two cases negative in scintigraphy but positive in whole body MR DWI and one case positive in scintigraphy only. There were eight lesions negative in scintigraphy but positive in whole body MR DWI, mainly located in the spine, pelvis and femur. Seven lesions were only detected by scintigraphy, mainly located in the skull, sternum, clavicle and scapula. Conclusion: The whole body MR DWI reveals excellent consistency with skeletal scintigraphy regarding bone metastasis, and the two modalities are complementary for each other. (authors)

  17. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.j [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  18. Whole-body MRI using a sliding table and repositioning surface coil approach

    International Nuclear Information System (INIS)

    Takahara, Taro; Kwee, Thomas; Luijten, Peter; Kibune, Satoshi; Ochiai, Reiji; Sakamoto, Tetsuro; Niwa, Tetsu; Van Cauteren, Marc

    2010-01-01

    To introduce and assess a new way of performing whole-body magnetic resonance imaging (MRI) using a non-integrated surface coil approach as available on most clinical MRI systems worldwide. Ten consecutive asymptomatic subjects prospectively underwent whole-body MRI for health screening. Whole-body MRI included T1-, T2- and diffusion-weighted sequences, and was performed using a non-integrated surface coil to image four different stations without patient repositioning. The four separately acquired stations were merged, creating seamless coronal whole-body T1-, T2- and diffusion-weighted images. Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations were qualitatively assessed. The average time (±SD) taken to change the surface coil from one station to the next station was 53.8 (±7.1) s. The average total extra examination time ± SD was 2 min 41.4 s (±15.3 s). Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations of T1-, T2- and diffusion-weighted whole-body MRI were overall graded as ''good'' to ''excellent''. This study shows that a time-efficient and high-quality whole-body MRI examination can easily be performed by using a non-integrated sliding surface coil approach. (orig.)

  19. Detection of bone metastasis of prostate cancer. Comparison of whole-body MRI and bone scintigraphy

    International Nuclear Information System (INIS)

    Ketelsen, D.; Roethke, M.; Aschoff, P.; Lichy, M.P.; Claussen, C.D.; Schlemmer, H.P.; Merseburger, A.S.; Reimold, M.

    2008-01-01

    Purpose: prostate cancer continues to be the third leading cancer-related mortality of western men. Early diagnosis of bone metastasis is important for the therapy regime and for assessing the prognosis. The standard method is bone scintigraphy. Whole-body MRI proved to be more sensitive for early detection of skeletal metastasis. However, studies of homogenous tumor entities are not available. The aim of the study was to compare bone scintigraphy and whole-body MRI regarding the detection of bone metastasis of prostate cancer. Materials and methods: 14 patients with histologically confirmed prostate cancer and a bone scintigraphy as well as whole-body MRI within one month were included. The mean age was 68 years. Scintigraphy was performed using the planar whole-body technique (ventral and dorsal projections). Suspect areas were enlarged. Whole-body MRI was conducted using native T1w and STIR sequences in the coronary plane of the whole body, sagittal imaging of spine and breath-hold STIR and T1w-Flash-2D sequences of ribs and chest. Bone scintigraphy and whole-body MRI were evaluated retrospectively by experienced radiologists in a consensus reading on a lesion-based level. Results: whole-body MRI detected significantly more bone metastasis (p = 0.024). 96.4% of the demonstrated skeletal metastases in bone scintigraphy were founded in whole-body MRI while only 58.6% of the depicted metastases in MRI were able to be located in scintigraphy. There was no significant difference regarding bone metastasis greater than one centimeter (p = 0.082) in contrast to metastasis less than one centimeter (p = 0.035). Small osteoblastic metastases showed a considerably higher contrast in T1w sequences than in STIR imaging. Further advantages of whole-body MRI were additional information about extra-osseous tumor infiltration and their complications, for example stenosis of spinal canal or vertebral body fractures, found in 42.9% of patients. (orig.)

  20. Proton MR spectroscopy and MR imaging in acute and chronic multiple sclerosis - ringlike appearances in acute plaques

    Energy Technology Data Exchange (ETDEWEB)

    Landtblom, A M [Dept. of Clinical Neuroscience, Linkoeping Univ. Hospital (Sweden); Sjoeqvist, L [Dept. of Radiation Physics, Linkoeping Univ. Hospital (Sweden); Soederfeldt, B [Dept. of Clinical Neuroscience, Linkoeping Univ. Hospital (Sweden); Nyland, H [Dept. of Neurology, Haukeland Hospital, Bergen (Norway); Thuomas, K Aa [Dept. of Radiology, Linkoeping Univ. Hospital (Sweden)

    1995-05-01

    We wanted to compare the metabolite status of brain lesions in different clinical subtypes of multiple sclerosis (MS). Two acute MS lesions with ringlike appearances were also investigated. Twenty-three clinically stable MS patients, 2 patients with acute relapses, and 15 healthy individuals were examined by MR imaging and localized proton MRS. No metabolite differences were seen in plaques of different subtypes. Decreased NAA/Cr and NAA/choline ratios as well as increased inositol/CR ratios were observed in the plaques of the clinically stable or chronic active MS patients as compared with controls. The ring plaques had hyperintense cores with surrounding halos, separated from the cores by rings with low signal intensity in T2-weighted images. The core exhibited a prolonged T2 relaxation time. Proton spectra initially contained lactate. No differences between the metabolite status of nonacute plaques in different clinical subtypes could be detected. The ring plaques contained lactate signals indicating oedema, inflammation, and macrophage invasion, and may be transition forms between acute oedematous lesions and chronic demyelinated plaques. (orig.).

  1. Effect of rat whole-body irradiation on oxidase chain and glucose-6-phosphatase of liver microsome: influence of cysteamine

    International Nuclear Information System (INIS)

    Bernard, Pierre.

    1979-11-01

    Three enzymatic systems of the male rat liver endoplasmic reticulum were studied by biochemical methods. Two means of investigation were used: - whole-body irradiation of the animal, - administration of cysteamine. The results obtained are discussed, in view of the functioning of these enzymatic systems, from two viewpoints: - the study of enzymatic radiolesions in relation to the radiobiological effect on the animal, the organ and the sub-cellular organite, - the study of chemical radioprotection. After a 900 R whole-body gamma irradiation a severe drop was observed in the enzymatic activity of two essential elements of the microsome oxydase chain: NADPH cytochrome P450 reductase and ethylmorphine N-demethylation. Glucose 6 phosphatase is also impaired by irradiation. Here it seems that the microsomal protein fraction could be responsible for the change in the enzyme activity. The irradiation effect is therefore not specific to one enzyme. The changes in these enzymatic activities correspond to the different phases of the acute irradiation syndrome which also affects the weight of the experimental animal and of the organ studied. Cysteamine used under chemical radioprotection conditions was found to be especially useful as a means of investigation complementary to the study of enzymatic radiolesions. From the combined action of irradiation and of the radioprotector it was possible to obtain a partial idea of the mechanisms of these radiolesions [fr

  2. Whole-Body Vibration Does Not Seem to Affect Postural Control in Healthy Active Older Women

    Directory of Open Access Journals (Sweden)

    P. S. C. Gomes

    2018-01-01

    Full Text Available Objective. This study investigated the acute residual effects induced by different frequencies of whole-body vibration (WBV on postural control of elderly women. Design. Thirty physically active elderly women (67±5 years were randomly divided into three groups: two experimental groups (high WBV frequency: 45 Hz and 4 mm amplitude, n=10; low WBV frequency: 30 Hz and 4 mm amplitude, n=10 and one control group (n=10, with no treatment. The participants were first subjected to stabilometry tests and were then guided through three sets of isometric partial squats for 60 s while the WBV stimulation was applied. The control group was subjected to the same conditions but without the WBV stimulation. The participants were again subjected to body balance tests immediately following the end of the intervention period and again at 8, 16, and 24 min. To measure body sway control, three 60 s tests were performed at 10 s intervals for each of the following experimental conditions: (1 eyes opened and (2 eyes closed. The following variables were investigated: the average velocity of the displacement of the centre of pressure in the anterior-posterior and medial-lateral planes as well as in the elliptical area. Results. A 3 (condition × 5 (test two-way repeated-measures ANOVA did not identify significant differences in the stabilometric variables, regardless of group, time, or experimental condition. Conclusions. The effect of WBV, regardless of the stimulation frequency, did not have a significant effect immediately after or up to 24 minutes after vibration cessation, on the variables involved in the control of postural stability in physically active elderly women.

  3. Neurocognitive responses to a single session of static squats with whole body vibration.

    Science.gov (United States)

    Amonette, William E; Boyle, Mandy; Psarakis, Maria B; Barker, Jennifer; Dupler, Terry L; Ott, Summer D

    2015-01-01

    The purpose of this study was to determine if the head accelerations using a common whole body vibration (WBV) exercise protocol acutely reduced neurocognition in healthy subjects. Second, we investigated differential responses to WBV plates with 2 different delivery mechanisms: vertical and rotational vibrations. Twelve healthy subjects (N = 12) volunteered and completed a baseline (BASE) neurocognitive assessment: the Immediate Postconcussion Assessment and Cognitive Test (ImPACT). Subjects then participated in 3 randomized exercise sessions separated by no more than 2 weeks. The exercise sessions consisted of five 2-minute sets of static hip-width stance squats, with the knees positioned at a 45° angle of flexion. The squats were performed with no vibration (control [CON]), with a vertically vibrating plate (vertical vibration [VV]), and with a rotational vibrating plate (rotational vibration [RV]) set to 30 Hz with 4 mm of peak-to-peak displacement. The ImPACT assessments were completed immediately after each exercise session and the composite score for 5 cognitive domains was analyzed: verbal memory, visual memory, visual motor speed, reaction time, and impulse control. Verbal memory scores were unaffected by exercise with or without vibration (p = 0.40). Likewise, visual memory was not different (p = 0.14) after CON, VV, or RV. Significant differences were detected for visual motor speed (p = 0.006); VV was elevated compared with BASE (p = 0.01). There were no significant differences (p = 0.26) in reaction time or impulse control (p = 0.16) after exercise with or without vibration. In healthy individuals, 10 minutes of 30 Hz, 4-mm peak-to-peak displacement vibration exposure with a 45° angle of knee flexion did not negatively affect neurocognition.

  4. Cardiopulmonary response during whole-body vibration training in patients with severe COPD

    Directory of Open Access Journals (Sweden)

    Rainer Gloeckl

    2017-03-01

    Full Text Available Several studies in patients with chronic obstructive pulmonary disease (COPD have shown that whole-body vibration training (WBVT has beneficial effects on exercise capacity. However, the acute cardiopulmonary demand during WBVT remains unknown and was therefore investigated in this study. Ten patients with severe COPD (forced expiratory volume in 1 s: 38±8% predicted were examined on two consecutive days. On day one, symptom-limited cardiopulmonary exercise testing was performed on a cycle ergometer. The next day, six bouts of repeated squat exercises were performed in random order for one, two or three minutes either with or without WBVT while metabolic demands were simultaneously measured. Squat exercises with or without WBVT induced comparable ventilatory efficiency (minute ventilation (VE/carbon dioxide production (V′CO2: 38.0±4.4 with WBVT versus 37.4±4.1 without, p=0.236. Oxygen uptake after 3 min of squat exercises increased from 339±40 mL·min−1 to 1060±160 mL·min−1 with WBVT and 988±124 mL min−1 without WBV (p=0.093. However, there were no significant differences between squat exercises with and without WBVT in oxygen saturation (90±4% versus 90±4%, p=0.068, heart rate (109±13 bpm versus 110±15 bpm, p=0.513 or dyspnoea (Borg scale 5±2 versus 5±2, p=0.279. Combining squat exercises with WBVT induced a similar cardiopulmonary response in patients with severe COPD compared to squat exercises without WBVT. Bearing in mind the small sample size, WBVT might be a feasible and safe exercise modality even in patients with severe COPD.

  5. Cardiopulmonary response during whole-body vibration training in patients with severe COPD.

    Science.gov (United States)

    Gloeckl, Rainer; Richter, Petra; Winterkamp, Sandra; Pfeifer, Michael; Nell, Christoph; Christle, Jeffrey W; Kenn, Klaus

    2017-01-01

    Several studies in patients with chronic obstructive pulmonary disease (COPD) have shown that whole-body vibration training (WBVT) has beneficial effects on exercise capacity. However, the acute cardiopulmonary demand during WBVT remains unknown and was therefore investigated in this study. Ten patients with severe COPD (forced expiratory volume in 1 s: 38±8% predicted) were examined on two consecutive days. On day one, symptom-limited cardiopulmonary exercise testing was performed on a cycle ergometer. The next day, six bouts of repeated squat exercises were performed in random order for one, two or three minutes either with or without WBVT while metabolic demands were simultaneously measured. Squat exercises with or without WBVT induced comparable ventilatory efficiency (minute ventilation ( V E)/carbon dioxide production ( V' CO 2 ): 38.0±4.4 with WBVT versus 37.4±4.1 without, p=0.236). Oxygen uptake after 3 min of squat exercises increased from 339±40 mL·min -1 to 1060±160 mL·min -1 with WBVT and 988±124 mL min -1 without WBV (p=0.093). However, there were no significant differences between squat exercises with and without WBVT in oxygen saturation (90±4% versus 90±4%, p=0.068), heart rate (109±13 bpm versus 110±15 bpm, p=0.513) or dyspnoea (Borg scale 5±2 versus 5±2, p=0.279). Combining squat exercises with WBVT induced a similar cardiopulmonary response in patients with severe COPD compared to squat exercises without WBVT. Bearing in mind the small sample size, WBVT might be a feasible and safe exercise modality even in patients with severe COPD.

  6. Whole-body imaging of the musculoskeletal system: the value of MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Gerwin P.; Reiser, Maximilian F.; Baur-Melnyk, Andrea [University Hospitals Munich/Grosshadern, LMU, Institute of Clinical Radiology, Munich (Germany)

    2007-12-15

    In clinical practice various modalities are used for whole-body imaging of the musculoskeletal system, including radiography, bone scintigraphy, computed tomography, magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET-CT). Multislice CT is far more sensitive than radiographs in the assessment of trabecular and cortical bone destruction and allows for evaluation of fracture risk. The introduction of combined PET-CT scanners has markedly increased diagnostic accuracy for the detection of skeletal metastases compared with PET alone. The unique soft-tissue contrast of MRI enables for precise assessment of bone marrow infiltration and adjacent soft tissue structures so that alterations within the bone marrow may be detected before osseous destruction becomes apparent in CT or metabolic changes occur on bone scintigraphy or PET scan. Improvements in hard- and software, including parallel image acquisition acceleration, have made high resolution whole-body MRI clinically feasible. Whole-body MRI has successfully been applied for bone marrow screening of metastasis and systemic primary bone malignancies, like multiple myeloma. Furthermore, it has recently been proposed for the assessment of systemic bone diseases predisposing for malignancy (e.g., multiple cartilaginous exostoses) and muscle disease (e.g., muscle dystrophy). The following article gives an overview on state-of-the-art whole-body imaging of the musculoskeletal system and highlights present and potential future applications, especially in the field of whole-body MRI. (orig.)

  7. Benefits of whole body vibration training in patients hospitalised for COPD exacerbations - a randomized clinical trial.

    Science.gov (United States)

    Greulich, Timm; Nell, Christoph; Koepke, Janine; Fechtel, Juliane; Franke, Maja; Schmeck, Bernd; Haid, Daniel; Apelt, Sandra; Filipovic, Silke; Kenn, Klaus; Janciauskiene, Sabina; Vogelmeier, Claus; Koczulla, Andreas Rembert

    2014-04-11

    Patients with stable COPD show improvements in exercise capacity and muscular function after the application of whole body vibration. We aimed to evaluate whether this modality added to conventional physiotherapy in exacerbated hospitalised COPD patients would be safe and would improve exercise capacity and quality of life. 49 hospitalised exacerbated COPD patients were randomized (1:1) to undergo physiotherapy alone or physiotherapy with the addition of whole body vibration. The primary endpoint was the between-group difference of the 6-minute walking test (day of discharge - day of admission). Secondary assessments included chair rising test, quality of life, and serum marker analysis. Whole body vibration did not cause procedure-related adverse events. Compared to physiotherapy alone, it led to significantly stronger improvements in 6-minute walking test (95.55 ± 76.29 m vs. 6.13 ± 81.65 m; p = 0.007) and St. Georges Respiratory Questionnaire (-6.43 ± 14.25 vs. 5.59 ± 19.15, p = 0.049). Whole body vibration increased the expression of the transcription factor peroxisome proliferator receptor gamma coactivator-1-α and serum levels of irisin, while it decreased serum interleukin-8. Whole body vibration during hospitalised exacerbations did not cause procedure-related adverse events and induced clinically significant benefits regarding exercise capacity and health-related quality of life that were associated with increased serum levels of irisin, a marker of muscle activity. German Clinical Trials Register DRKS00005979. Registered 17 March 2014.

  8. Whole Body Magnetic Resonance Imaging in the Diagnosis of Parsonage Turner Syndrome

    International Nuclear Information System (INIS)

    Ryan, M.; Twair, A.; Nelson, E.; Brennan, D.; Eustace, S.

    2004-01-01

    Purpose: To describe magnetic resonance imaging (MRI) findings in patients with suspected Parsonage Turner syndrome and to emphasize the value of an additional whole body MR scan to improve specificity of this diagnosis. Material and Methods: Three patients with proven Parsonage Turner syndrome referred for conventional MRI of the shoulder girdle and additional whole body turboSTIR MRI were included for study. Results: In each case, imaging revealed edema in the muscles of the shoulder girdle. Whole body turboSTIR MRI scan confirmed localized unilateral changes in each case improving specificity and confidence in the diagnosis of Parsonage Turner syndrome in each case. Conclusion: Whole body turboSTIR MR imaging is a useful diagnostic tool in the evaluation of patients with suspected Parsonage Turner syndrome. Inclusion of the brain, neck, brachial plexus, and extremity musculature at whole body imaging allows differentiation from polymyositis and elimination of additional causes of shoulder girdle pain and weakness including gross lesions in the brain, neck, and brachial plexus by a single non-invasive study

  9. Retrospective Evaluation of Whole Body Computed Tomography for Tumor Staging in Dogs with Primary Appendicular Osteosarcoma.

    Science.gov (United States)

    Talbott, Jessica L; Boston, Sarah E; Milner, Rowan J; Lejeune, Amandine; Souza, Carlos H de M; Kow, Kelvin; Bacon, Nicholas J; Hernandez, Jorge A

    2017-01-01

    To evaluate whole body computed tomography (CT) for staging canine appendicular osteosarcoma. Retrospective case series. Client-owned dogs diagnosed with appendicular osteosarcoma (n=39). Medical records for client-owned dogs diagnosed with appendicular osteosarcoma from August 2008 to July 2014 were reviewed. Dogs were included if they had a confirmed diagnosis of appendicular osteosarcoma and were staged using whole body CT. Data collected included signalment, body weight, primary tumor location, serum alkaline phosphatase (ALP) activity, findings on 3-view thoracic radiographs, cytologic or histologic results, and findings on CT. Thirty-nine dogs (median age 8.5 years; median body weight 37 kg) had osteosarcoma of the distal radius (n=17), proximal humerus (11) and other sites. Serum ALP activity was elevated in 14 dogs. Bone metastasis was not detected in any dog on whole body CT. Pulmonary metastasis was considered definitive on CT based on board certified radiologist assessment in 2/39 dogs (5%). Two additional dogs (2/39, 5%) had soft tissue masses diagnosed on CT, consistent with concurrent, non-metastatic malignancies. Bone metastases were not identified in any dog with whole body CT. Thoracic and abdominal CT detected lung lesions and concurrent neoplasia in dogs with primary appendicular osteosarcoma. Whole body CT may be a useful adjunct to other screening tests for disseminated malignancy. © 2016 The American College of Veterinary Surgeons.

  10. Proton Therapy for Spinal Ependymomas: Planning, Acute Toxicities, and Preliminary Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Amsbaugh, Mark J. [Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Grosshans, David R., E-mail: dgrossha@mdanderson.org [Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); McAleer, Mary Frances; Zhu, Ron; Wages, Cody; Crawford, Cody N.; Palmer, Matthew; De Gracia, Beth; Woo Shiao; Mahajan, Anita [Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2012-08-01

    Purpose: To report acute toxicities and preliminary outcomes for pediatric patients with ependymomas of the spine treated with proton beam therapy at the MD Anderson Cancer Center. Methods and Materials: Eight pediatric patients received proton beam irradiation between October 2006 and September 2010 for spinal ependymomas. Toxicity data were collected weekly during radiation therapy and all follow-up visits. Toxicities were graded according to the Common Terminology Criteria for Adverse Events version 3.0. Results: All patients had surgical resection of the tumor before irradiation (7 subtotal resection and 1 gross total resection). Six patients had World Health Organization Grade I ependymomas, and two had World Health Organization Grade II ependymomas. Patients had up to 3 surgical interventions before radiation therapy (range, 1-3; median, 1). Three patients received proton therapy after recurrence and five as part of their primary management. The entire vertebral body was treated in all but 2 patients. The mean radiation dose was 51.1 cobalt gray equivalents (range, 45 to 54 cobalt gray equivalents). With a mean follow-up of 26 months from the radiation therapy start date (range, 7-51 months), local control, event-free survival, and overall survival rates were all 100%. The most common toxicities during treatment were Grade 1 or 2 erythema (75%) and Grade 1 fatigue (38%). No patients had a Grade 3 or higher adverse event. Proton therapy dramatically reduced dose to all normal tissues anterior to the vertebral bodies in comparison to photon therapy. Conclusion: Preliminary outcomes show the expected control rates with favorable acute toxicity profiles. Proton beam therapy offers a powerful treatment option in the pediatric population, where adverse events related to radiation exposure are of concern. Extended follow-up will be required to assess for late recurrences and long-term adverse effects.

  11. Whole-body function-scintigraphic investigations for the determination of reginal blood volumina and their variations

    International Nuclear Information System (INIS)

    Mostbeck, A.; Partsch, H.

    1976-01-01

    Changes of regional blood volume in the different parts of the body were observed by functional whole body scanning after injection of a tracer which remains sufficiently in the vascular beds to enable acute examinations sup(99m)Tc. In 21 persons changes of regional blood volume compression of both legs) and by pharmacological influences (dihydroergotamine, nifedipine, nitroglycerin, noradrenalin, dopamin). In both venous occlusion and compression of the legs a reciprocal relationship was observed between the blood volume of the legs and that of the central regions of the body. Dihydroergotamine, noradrenalin and dopamin caused a displacement of blood volume towards the central regions. After the application of nitroglycerin there was an increase of blood volume in the arms and in the legs and a distinct decrease of the thoracal blood volume

  12. Modulation of the gut microbiota with antibiotic treatment suppresses whole body urea production in neonatal pigs

    DEFF Research Database (Denmark)

    Puiman, Patrycja; Stoll, Barbara; Mølbak, Lars

    2013-01-01

    We examined whether changes in the gut microbiota induced by clinically relevant interventions would impact the bioavailability of dietary amino acids in neonates. We tested the hypothesis that modulation of the gut microbiota in neonatal pigs receiving no treatment (control), intravenously...... administered antibiotics, or probiotics affects whole body nitrogen and amino acid turnover. We quantified whole body urea kinetics, threonine fluxes, and threonine disposal into protein, oxidation, and tissue protein synthesis with stable isotope techniques. Compared with controls, antibiotics reduced...... the number and diversity of bacterial species in the distal small intestine (SI) and colon. Antibiotics decreased plasma urea concentrations via decreased urea synthesis. Antibiotics elevated threonine plasma concentrations and turnover, as well as whole body protein synthesis and proteolysis. Antibiotics...

  13. Disseminated cysticercosis in a child: whole-body MR diagnosis with the use of parallel imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Atin; Goenka, Ajit Harishkumar [All India Institute of Medical Sciences, Department of Radiology, New Delhi, Delhi (India); Choudhary, Anita; Sahu, Jitendra Kumar; Gulati, Sheffali [All India Institute of Medical Sciences, Department of Paediatrics, New Delhi, Delhi (India)

    2010-02-15

    Cysticercosis is a parasitic disease caused by infestation with the encysted larval stage of the pork tapeworm, Taenia solium. Disseminated cysticercosis is an exceptional expression of this disease characterized by high morbidity due to massive symptomatic parasite burden in the central nervous system, striated muscles, subcutaneous tissues and other organs. Less than 50 such cases have been reported worldwide, and fewer than 10 children. We report on the whole-body MR diagnosis of extensively disseminated cysticercosis in a child. The critical role of whole-body MR as a stand-alone modality in the diagnosis and management of this pleomorphic disease is highlighted. Whole-body MR diagnosis of an infectious disease is unique. (orig.)

  14. Comparison of atlas-based techniques for whole-body bone segmentation

    DEFF Research Database (Denmark)

    Arabi, Hossein; Zaidi, Habib

    2017-01-01

    out in terms of estimating bone extraction accuracy from whole-body MRI using standard metrics, such as Dice similarity (DSC) and relative volume difference (RVD) considering bony structures obtained from intensity thresholding of the reference CT images as the ground truth. Considering the Dice....../MRI. To this end, a variety of atlas-based segmentation strategies commonly used in medical image segmentation and pseudo-CT generation were implemented and evaluated in terms of whole-body bone segmentation accuracy. Bone segmentation was performed on 23 whole-body CT/MR image pairs via leave-one-out cross...... validation procedure. The evaluated segmentation techniques include: (i) intensity averaging (IA), (ii) majority voting (MV), (iii) global and (iv) local (voxel-wise) weighting atlas fusion frameworks implemented utilizing normalized mutual information (NMI), normalized cross-correlation (NCC) and mean...

  15. Determination of calibration factors for whole body counting of members of public

    International Nuclear Information System (INIS)

    Vijayagopal, P.; Joyeeta, M.; Garg, S.P.; Vidhani, J.M.; Pendharkar, K.A.

    2005-01-01

    A Mobile Radiological Laboratory (MRL) was recently developed by Internal Dosimetry Division in BARC. In the event of an accident involving release of radioactive substances into the environment, there will be a need to measure both the external and the internal exposure of the population. MRL has been equipped with a variety of radiation detectors, radiation survey meters and a whole body monitor for this purpose. For whole body monitoring of members of public, detector systems are required to be calibrated with the age dependent phantoms of appropriate size for both male and female subjects. In this paper we present the results of the calibration studies carried out with shielded chair whole body counter of MRL using five different age dependent male phantoms representing the age groups of 1,5,10 and 15 year old children and 20 year old adult. Calibration work has been carried out using standard sources of 137 Cs, 133 Ba and 60 Co. (author)

  16. Application of Whole Body Counter to Neutron Dose Assessment in Criticality Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, O.; Tsujimura, N.; Takasaki, K.; Momose, T.; Maruo, Y. [Japan Nuclear Cycle Development Institute, Tokai (Japan)

    2001-09-15

    Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of {sup 24}Na in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of {sup 24}Na is approximately 50Bq for 10minute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 [(Bq{sup 24}Na/g{sup 23}Na)/mGy].

  17. Calibration of Single High Purity Germanium Detector for Whole Body Counter

    International Nuclear Information System (INIS)

    Taha, T.M.; Morsi, T.M.

    2009-01-01

    A new Accuscan II single germanium detector for whole body counter was installed in NRC (Egypt). The current paper concerned on calibration of single high purity germanium detector for whole body counter. Physical parameters affecting on performance of whole body counter such as linearity, minimum detectable activity and source detector distance, SDD were investigated. Counting efficiencies for the detector have been investigated in rear wall, fixed diagnostic position in air. Counting efficiencies for organ compartments such as thyroid, lung, upper and lower gastrointestinal tract have been investigated using transfer phantom in fixed diagnostic and screening positions respectively. The organ compartment efficiencies in screening geometry were higher than that value of diagnostic geometry by a factor of three. The committed dose equivalents of I-131 in thyroid were ranged from 0.073 ± 0.004 to 1.73±0.09 mSv and in lung was 0.02±0.001 mSv

  18. Analysis of whole-body vibration on rheological models for tissues

    Science.gov (United States)

    Neamţu, A.; Simoiu, D.; Nyaguly, E.; Crastiu, I.; Bereteu, L.

    2018-01-01

    Whole body vibrations have become a very popular method in recent years, both in physical therapy and in sports. This popularity is due to the fact that, as a result of analyzing the groups of subjects, the effects of small amplitude vibration and low frequency vibration, it was found an increase in the force developed by the feet, a hardening of bone strength or an increase in bone density. In this paper we propose to give a possible explanation of the stress relieving in muscle and/or bone after whole body vibration treatment. To do this we consider some rheological models which after whole body vibrations and after the analysis of their response lead to various experiments.

  19. Simplified calibration and evaluation procedures for improvised whole body gamma spectrometry in emergency situations

    International Nuclear Information System (INIS)

    Malatova, I.; Bucina, I.; Drabova, D.; Cespirova, I.

    2000-01-01

    A semiconductor gamma spectrometer could be used for the rapid estimation of internal contamination of the people in cases of accidents even when no special calibration for whole body counting is prepared. Generic transfer factors for calculation of the whole body detection efficiency from the 25 cm distant point source detection efficiency are presented. Generic dependence of parameters of power function describing the detector efficiency for point source in 25 cm on the detector relative efficiency given by producer was derived from calibration of 18 detectors with relative efficiency from 1.4% to 62%. Minimum detectable activity for various backgrounds and the uncertainty of the estimate of whole body retention are presented, too. (author)

  20. Whole body measurements of sodium turnover in offspring of patients with sustained essential hypertension

    International Nuclear Information System (INIS)

    Henningsen, N.C.; Ohlsson, O.; Mattson, S.; Nosslin, B.; Lund Univ.; Lund Univ.

    1982-01-01

    The elimination rate (percent per day) of injected 22 Na using a whole body measurement technique was significantly lower (26%, 5.8 +- 1.5) in normotensive of borderline hypertensive offspring of essential hypertensive patients than in 15 age- and sex-matched, normotensive controls (7.3 +- 1.0). There were no significant differences in exchangeable sodium, whole body potassium or in the urinary exeretion of sodium, potassium and creatinine. The basis for the difference in turnover rate during weck 1 is probably an alteration in the cellular handling of sodium (i.e. increased intracellular sodium) in the still normotensive offspring of patients with essential hypertension. The long-term (more than 100 days) whole body retention of 22 Na was found to be only 0.1% of that injected, which justifies the use of the method on larger population groups. (orig.)

  1. Morphological studies on the healing process of tooth extraction wounds in whole body irradiated rats

    International Nuclear Information System (INIS)

    Hosokawa, Yoichiro

    1991-01-01

    The present studies were performed to investigate the healing process of the tooth extraction wound in whole body irradiated rats and to clarify the effect of irradiation on bone metabolism. One hundred and seven Wistar rats of about 100 g body weight were used and divided into 3 groups. Whole body irradiated rats were given single exposure with a dose of 8 Gy. The region of the left upper molars of local irradiated rats as controls, was exposed to 8 Gy. On the 7th day after irradiation, the left upper first molar of each rat was extracted. The rats were sacrificed at intervals of 1 to 14 days after extraction. Non-irradiated rats were sacrificed at the same intervals after extraction. The maxillary bone including the extraction wound was evaluated, histologically, histometrically and ultrastructurally. From the histological and histometrical findings, the difference of the healing process between non-irradiated rats and locally irradiated rats is not significant. In whole body irradiated rats, the healing process especially in the socket was disturbed. The osteoblastic new bone formation following production of granulation tissue was interfered with. Ultrastructurally, the cytoplasmic organellae were poorly developed in the osteoblast and osteoid formation was reduced in the socket. But periosteal new bone formation was the same as that of the locally irradiated rats. In whole body irradiated rats, the osteoclasts in the interradicular alveolar bone were decreased and have smaller nuclei, compared with non-irradiated and locally irradiated rats. Histometrically, the amount of bone loss was decreased in whole body irradiated rats. Ultrastructurally, the cyoplasmic organellae and ruffled border were poorly developed in the osteoclasts of whole body irradiated rats. The findings suggested that irradiation induced cytological changes not only in osteoblasts but in osteoclasts and these changes resulted in the delayed healing of extraction wound. (author) 106 refs

  2. Morphological studies on the healing process of tooth extraction wounds in whole body irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Yoichiro (Hokkaido Univ., Sapporo (Japan). School of Dentistry)

    1991-06-01

    The present studies were performed to investigate the healing process of the tooth extraction wound in whole body irradiated rats and to clarify the effect of irradiation on bone metabolism. One hundred and seven Wistar rats of about 100 g body weight were used and divided into 3 groups. Whole body irradiated rats were given single exposure with a dose of 8 Gy. The region of the left upper molars of local irradiated rats as controls, was exposed to 8 Gy. On the 7th day after irradiation, the left upper first molar of each rat was extracted. The rats were sacrificed at intervals of 1 to 14 days after extraction. Non-irradiated rats were sacrificed at the same intervals after extraction. The maxillary bone including the extraction wound was evaluated, histologically, histometrically and ultrastructurally. From the histological and histometrical findings, the difference of the healing process between non-irradiated rats and locally irradiated rats is not significant. In whole body irradiated rats, the healing process especially in the socket was disturbed. The osteoblastic new bone formation following production of granulation tissue was interfered with. Ultrastructurally, the cytoplasmic organellae were poorly developed in the osteoblast and osteoid formation was reduced in the socket. But periosteal new bone formation was the same as that of the locally irradiated rats. In whole body irradiated rats, the osteoclasts in the interradicular alveolar bone were decreased and have smaller nuclei, compared with non-irradiated and locally irradiated rats. Histometrically, the amount of bone loss was decreased in whole body irradiated rats. Ultrastructurally, the cyoplasmic organellae and ruffled border were poorly developed in the osteoclasts of whole body irradiated rats. The findings suggested that irradiation induced cytological changes not only in osteoblasts but in osteoclasts and these changes resulted in the delayed healing of extraction wound. (author) 106 refs.

  3. Whole body perfusion for hybrid aortic arch repair: evolution of selective regional perfusion with a modified extracorporeal circuit.

    Science.gov (United States)

    Fernandes, Philip; Walsh, Graham; Walsh, Stephanie; O'Neil, Michael; Gelinas, Jill; Chu, Michael W A

    2017-04-01

    Patients undergoing hybrid aortic arch reconstruction require careful protection of vital organs. We believe that whole body perfusion with tailored dual circuitry may help to achieve optimal patient outcomes. Our circuit has evolved from a secondary circuit utilizing a cardioplegia delivery device for lower body perfusion to a dual-oxygenator circuit. This allows individually controlled regional perfusion with ease of switching from secondary to primary circuit for total body flow. The re-design allows for separate flow and temperature regulation with two oxygenators in parallel. All patients underwent a single-stage operation for simultaneous treatment of arch and descending aortic pathology via a sternotomy, using a hybrid frozen elephant trunk technique. We report six consecutive patients undergoing hybrid arch and frozen elephant trunk reconstruction using a dual-oxygenator circuit. Five patients underwent elective surgery and one was emergent. One patient had an acute dissection while three underwent concomitant procedures, including a Ross procedure and two valve-sparing root reconstructions. Three cases were redo sternotomies. The mean pump time was 358 ± 131 min, the aortic cross clamp time 243 ± 135 min, the cardioplegia volume of 33,208 ml ± 16,173, cerebral ischemia 0 min, lower body ischemia 76 ± 34 min and the average lower body perfusion time was 142 min. Two patients did not require any donor blood products. The median intensive care unit (ICU) and hospital lengths of stay (LOS) were two days and 10 days, respectively. The average peak serum lactate on CPB was 7.47 mmol/L and, at admission to the ICU, it was 3.37 mmol/L. Renal and respiratory failure developed in the salvage acute type A dissection patient. No other complications occurred in this series. Whole body perfusion as delivered through individually controlled dual-oxygenator circuitry allows maximum flexibility for hybrid aortic arch reconstruction. A modified circuit perfusion

  4. Validation of Experimental whole-body SAR Assessment Method in a Complex Indoor Environment

    DEFF Research Database (Denmark)

    Bamba, Aliou; Joseph, Wout; Vermeeren, Gunter

    2012-01-01

    Assessing experimentally the whole-body specific absorption rate (SARwb) in a complex indoor environment is very challenging. An experimental method based on room electromagnetics theory (accounting only the Line-Of-Sight as specular path) to assess the whole-body SAR is validated by numerical...... of the proposed method is that it allows discarding the computation burden because it does not use any discretizations. Results show good agreement between measurement and computation at 2.8 GHz, as long as the plane wave assumption is valid, i.e., for high distances from the transmitter. Relative deviations 0...

  5. Whole body clearance of norepinephrine. The significance of arterial sampling and of surgical stress

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Madsbad, S

    1983-01-01

    The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively, in the ......The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively...

  6. A preliminary study of iron absorption by whole body counting and correlation with DFO excretion

    International Nuclear Information System (INIS)

    Gupta, M.M.; Bhattacharyya, L.; Gupta, N.K.; Bhola, G.C.; Nagaratnam, A.; Manchanda, R.; Bhargva, M.; Kumar, S.

    1975-01-01

    A preliminary study of iron absorption by oral administration of 59 Fe and whole body counting was carried on a group of 16 women. The cases included 8 patients suffering from iron deficiency anaemia and various infections as well as 8 healthy controls. High iron absorption is associated with iron deficiency, these changes being more marked in iron deficient controls than in those with infection or malignancy. In iron deficient controls results of whole body counting correlate very well with other haematological investigations. (orig.) [de

  7. Synthesis of dendrimer-based biotin radiopharmaceuticals to enhance whole-body clearance

    International Nuclear Information System (INIS)

    Sato, Noriko; Park, Chang W.; Kim, Hyung-Sik; Han, Eui-Sik; Wong, Karen J.; Paik, Ronald S.; Park, Luke S.; Yao Zhengsheng; Carrasquillo, Jorge A.; Paik, Chang H.

    2003-01-01

    To synthesize a biotin radiopharmaceutical that clears rapidly, dendrimer was used as a carrier and conjugated with succinimidyl 3-[ 125 I]iodobenzoate and tetrafluorophenyl norbiotinamidosuccinate. Then, succinic anhydride was used to reduce its pI. In mice, the non-succinylated product showed high liver (67% ID/g) and kidney (44% ID/g) uptakes and whole-body retention (94% ID) at 20 min that persisted for 12 hr. The corresponding organ uptakes (22% and 11% ID/g) and the whole-body retention (47% ID) were drastically reduced by succinylation (p<0.0001). Lysine co-injection further lowered renal uptake

  8. Whole body computed tomographic findings of each one case with primary aldosteronism and Cushing syndrome

    International Nuclear Information System (INIS)

    Kamata, Shuji; Kawamura, Koro; Nakamura, Motoyuki

    1980-01-01

    We here report each one case with primary aldosteronism (male, 28 years old) and Cushing syndrome (female, 37 years old). Both of the cases showed characteristic clinical signs of hypertension and typical laboratory findings of adreno-hormonal assays. In performance of whole body computed tomography, clear pictures of tumorous adenomas in both cases were taken and the sizes of adenomas in picture were completely same as the masses obtained by the lateral adrenectomies. As a result, the whole body computed tomography is very useful to diagnose the diseases of adrenal adenoma and hyperplasia. (author)

  9. Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics

    DEFF Research Database (Denmark)

    Maroy, Renaud; Boisgard, Raphaël; Comtat, Claude

    2008-01-01

    Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new...... method for the segmentation of rodent whole-body PET images that takes these two difficulties into account by estimating the pharmacokinetics far from organ borders. The segmentation method proved efficient on whole-body numerical rat phantom simulations, including 3-14 organs, together...

  10. Acid base balance in the rabbit following whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Bassant, M.-H.; Touchard, Francoise; Court, Louis

    1981-01-01

    2 hrs. after whole-body gamma irradiation (doses of 1.5 and 4.5 Gy) a metabolic acidosis developed in curarised Rabbits placed under artificial respiration in order to eliminate radiation-induced respiratory effect. The metabolic acidosis was evaluated by measurement of the negative base excess. The results were compared to others obtained under different experimental procedures [fr

  11. Acid base balance in the rabbit following whole-body gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bassant, M.H.; Touchard, F.; Court, L. (CEA Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Recherches sur la Fusion Controlee)

    1981-07-06

    2 hrs. after whole-body gamma irradiation (doses of 1.5 and 4.5 Gy) a metabolic acidosis developed in curarised rabbits placed under artificial respiration in order to eliminate radiation-induced respiratory effect. The metabolic acidosis was evaluated by measurement of the negative base excess. The results were compared to others obtained under different experimental procedures.

  12. Metabolism and Whole-Body Fat Oxidation Following Post-Exercise Carbohydrate or Protein Intake

    DEFF Research Database (Denmark)

    Hall, Ulrika Andersson; Pettersson, Stefan; Edin, Fredrik

    2018-01-01

    : Protein supplementation immediately post-exercise did not affect the doubling in whole body fat oxidation seen during a subsequent exercise trial 2 hours later. Neither did it affect resting fat oxidation during the post-exercise period despite increased insulin levels and attenuated ketosis. Carbohydrate...

  13. Influence of Tire Characteristics of Interurban Taxis on Exposure Level to Drivers Whole-Body Vibrations

    Directory of Open Access Journals (Sweden)

    Milad Derakhshanjazari

    2016-03-01

    Full Text Available Introduction: Taxi drivers’ exposure to repeat whole-body vibrations can cause back pain and digestive disorders. Since this type of vibration depends on the car components, this study was carried out to determine the influence of tire characteristics on the amount of whole-body vibrations transmitted to the Peugeot 405 taxi drivers. Methods: In this experimental study, vibration characteristics were measured according to the ISO2631-1 with each of the statuses: tubeless tires fixed and fluid in it (normal air or nitrogen and also the fluid in the tires fixed with tubes or tubeless on asphalt-paved road. Other variables including tire pressure, engine speed, road gradient, number of passengers, springs, and shock absorbers were kept constant. Then the effect of changes was analyzed using an appropriate statistical test. Results: After changing nitrogen to normal air and tubeless tires to tube, the average of RMS in Z-axis, eight-hour equivalent acceleration A(8 and crest factor were reduced (P 0.9 m/s2 to caution zone (0.45-0.9 m/s2 with a value of 0.8 m/s2. Conclusions: The amount of vibration transmitted to the whole body is sensitive to existence of tubes and tires inflation so that we can reduce the amount of whole-body vibration to lower than the upper limit of the health risk by changing the characteristics of the tire

  14. Whole body dosimetry for treatment individualized neuroblastoma with 131I-MIBG

    International Nuclear Information System (INIS)

    Ferrer Gracia, C.; Luquero Llopis, N.; Sanchez Munoz, F.; Plaza Aparicio, R.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    It according to in this study, that in therapy with 1 31I-MIBG for the treatment of neuroblastoma, it can prescribe and manage dose whole body accurately, allowing individualized treatments and major activities that in the treatments based on a fixed activity according to weight management. (Author)

  15. Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

    DEFF Research Database (Denmark)

    Keller, Sune H; Holm, Søren; Hansen, Adam E

    2013-01-01

    Integrated whole-body PET/MRI tomographs have become available. PET/MR imaging has the potential to supplement, or even replace combined PET/CT imaging in selected clinical indications. However, this is true only if methodological pitfalls and image artifacts arising from novel MR-based attenuation...

  16. Pharmacokinetics and whole body distribution of elastase derived angiostatin (k1-3) in rats

    NARCIS (Netherlands)

    Molema, Grietje; van Veen-Hof, Ingrid; van Loenen - Weemaes, Anne-miek; Proost, Johannes; de Leij, Lou F.M.H.; Meijer, Dirk K.F.

    2001-01-01

    In the current study, we determined short-term pharmacokinetics and whole body distribution of elastase derived angiostatin [angiostatin((k1-3))] in rats after i.v. injection of radiolabelled protein. Since In gamma-camera studies, no tumor specific angiostatin((k1-3)) accumulation was observed,

  17. Changes in plasma (hydrocortisone) levels after whole-body irradiation with ultraviolet rays of defined wavelengths

    International Nuclear Information System (INIS)

    Bartelt, R.N.

    1983-01-01

    One hour after whole-body irradiation with a radiation source having its maximum of emission in the UVB range, at a radiation dose of 0.44 J/cm 2 , a significant fall in the mean values of the blood plasma hydrocortisone level (p [de

  18. Potential effects of whole-body vibration exercises on blood flow ...

    African Journals Online (AJOL)

    Feasible clinical strategies such as whole-body vibration exercise (WBVE) are being used without a clear understanding of its effects. The aim of the present study is to review the effects of the WBVE on blood flow kinetics and its feasibility in different populations. Material and Methods: The level of evidence (LE) of selected ...

  19. A statistical observation on some subjects in the whole body computed tomographic examination

    International Nuclear Information System (INIS)

    Murakami, Shozo; Matsumoto, Shigekazu; Murakawa, Yasuhiro; Morimoto, Mitsuo; Nakai, Toshio

    1983-01-01

    Since the whole body CT (computed tomography) unit (GE, CT/T) was installed in our hospital in April, 1982, a total of 2884 cases have been examined by this whole body scanner for one year from April, 1982 to March, 1983. An analysis of the relationship between the situations of the subjects in and the results of whole body CT examination disclosed some very interesting facts. Up to the present time such a study has scarcely made. That is why we wanted to make this report. The results obtained are as follows: 1. Whole body CT examinations were performed on the patients of advanced age more frequently than on those of young age and performed most frequently on the group in the sixties. 2. The number of CT examinations performed on head and abdomen of the patients was 86.7% of a total of 2884 cases. 3. Enhanced CT examinations were perfomed on 26.1% of 2884 cases and most frequently on the group in the teens. 4. The percentage of the abnormal findings found in 2884 cases was 61.5% and this rate was higher than that shown in the reports made by us in 1980 and 1982, respectively. (author)

  20. Intermittent fasting does not affect whole-body glucose, lipid, or protein metabolism

    NARCIS (Netherlands)

    Soeters, Maarten R.; Lammers, Nicolette M.; Dubbelhuis, Peter F.; Ackermans, Mariëtte T.; Jonkers-Schuitema, Cora F.; Fliers, Eric; Sauerwein, Hans P.; Aerts, Johannes M.; Serlie, Mireille J.

    2009-01-01

    Background: Intermittent fasting (IF) was shown to increase whole-body insulin sensitivity, but it is uncertain whether IF selectively influences intermediary metabolism. Such selectivity might be advantageous when adapting to periods of food abundance and food shortage. Objective: The objective was

  1. Effects of whole-body vibration on muscle strength and power of elderly: A systematic review

    Directory of Open Access Journals (Sweden)

    Monique Opuszcka Campos

    2014-02-01

    Full Text Available The aim of this systematic review was to summarize available scientific evidence on the utilization of whole body vibration as an alternative method to promote effective modifications on muscle strength and power in the aging population.  Scientific studies were retrieved from the following databases: Medline, Scielo, Lillacs, Cochrane Library, PEDro and Science Citation Index. The PEDro scale was used to assess the quality of the included studies, while content went through a critical analysis. From the 91 studies retrieved, 75 were excluded and 16 attended the selection criteria. From the16, the majority (68.8% presented from moderate to high methodological quality. Whole-body vibration associated to both isometric and dynamic exercises seemed to constitute an alternative for therapeutic intervention to improve muscular strength and power of healthy elderly. However, due to the characteristics of the designs of the studies reviewed and the threats to their internal validity (i.e., the absence of the control condition to the vibratory stimulus it was challenging to establish the additional effects of the whole-body vibration on the target population. Divergent findings were found for the whole-body vibration effect on muscular power. It is still necessary to conduct randomized control trials to establish the real effectiveness of this kind of intervention.

  2. Back disorders in crane operators exposed to whole-body vibration

    NARCIS (Netherlands)

    Bongers, P. M.; Boshuizen, H. C.; Hulshof, C. T.; KOEMEESTER, A. P.

    1988-01-01

    In The Netherlands so far little research has been carried out to investigate the health effects of exposure to whole-body vibration at work. In a retrospective (10-year) follow-up study, the incidence of permanent work disabilities in crane operators exposed to vibration was compared to that of a

  3. Effects of Whole-Body Vibration Therapy in Patients with Fibromyalgia: A Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Daniel Collado-Mateo

    2015-01-01

    Full Text Available Objective. To review the literature on the effects of whole-body vibration therapy in patients with fibromyalgia. Design. Systematic literature review. Patients. Patients with fibromyalgia. Methods. An electronic search of the literature in four medical databases was performed to identify studies on whole-body vibration therapy that were published up to the 15th of January 2015. Results. Eight articles satisfied the inclusion and exclusion criteria and were analysed. According to the Dutch CBO guidelines, all selected trials had a B level of evidence. The main outcomes that were measured were balance, fatigue, disability index, health-related quality of life, and pain. Whole-body vibration appeared to improve the outcomes, especially balance and disability index. Conclusion. Whole-body vibration could be an adequate treatment for fibromyalgia as a main therapy or added to a physical exercise programme as it could improve balance, disability index, health-related quality of life, fatigue, and pain. However, this conclusion must be treated with caution because the paucity of trials and the marked differences between existing trials in terms of protocol, intervention, and measurement tools hampered the comparison of the trials.

  4. Mitochondrial monoaminoxidase activity and serotonin content in rat brain after whole-body γ-irradiation

    International Nuclear Information System (INIS)

    Savitskij, I.V.; Tsybul'skij, V.V.; Grivtsev, B.A.

    1985-01-01

    It is shown that γ-irradiation of albino rats with a dose of 30 Gy leads to pronounced phase changes in monoaminoxidase activity and serotonin content in rat brain at early times after whole-body exposure. These is a similar direction of changes in the activity of the enzyme and in the content of the substrate adequate to the latter

  5. DETECTION OF WHOLE BODY OXIDATIVE STRESS IN URINE USING OXYGEN-18 LABELING

    Science.gov (United States)

    DETECTION OF WHOLE BODY OXIDATIVE STRESS IN URINE USING OXYGEN-18 LABELING. R Slade, J L McKee and G E Hatch. PTB, ETD, NHEERL, ORD, USEPA, Research Triangle Park, NC, USA.Reliable non-invasive markers for detecting oxidative stress in vivo are currently not available. We pr...

  6. Moving along the Mental Number Line: Interactions between Whole-Body Motion and Numerical Cognition

    Science.gov (United States)

    Hartmann, Matthias; Grabherr, Luzia; Mast, Fred W.

    2012-01-01

    Active head turns to the left and right have recently been shown to influence numerical cognition by shifting attention along the mental number line. In the present study, we found that passive whole-body motion influences numerical cognition. In a random-number generation task (Experiment 1), leftward and downward displacement of participants…

  7. Whole body and muscle energy metabolism in preruminant calves: effects of nutrient synchrony and physical activity

    NARCIS (Netherlands)

    Borne, van den J.J.G.C.; Hocquette, J.F.; Verstegen, M.W.A.; Gerrits, W.J.J.

    2007-01-01

    The effects of asynchronous availability of amino acids and glucose on muscle composition and enzyme activities in skeletal muscle were studied in preruminant calves. It was hypothesized that decreased oxidative enzyme activities in muscle would explain a decreased whole body heat production with

  8. Effect of whole body resistance training on arterial compliance in young men.

    NARCIS (Netherlands)

    Rakobowchuk, M.; McGowan, C.L.; Groot, P.C.E. de; Bruinsma, D.; Hartman, J.W.; Phillips, S.M.; MacDonald, M.J.

    2005-01-01

    The effect of resistance training on arterial stiffening is controversial. We tested the hypothesis that resistance training would not alter central arterial compliance. Young healthy men (age, 23 +/- 3.9 (mean +/- s.e.m.) years; n = 28,) were whole-body resistance trained five times a week for 12

  9. Suitability of Kinect for measuring whole body movement patterns during exergaming

    NARCIS (Netherlands)

    van Diest, Mike; Stegenga, Jan; Wortche, Heinrich J.; Postema, Klaas; Verkerke, Gijsbertus J.; Lamoth, Claudine J. C.

    2014-01-01

    Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present

  10. Human and animal studies: portals into the whole body and whole population response

    Science.gov (United States)

    Human and animal studies: portals into the whole body and whole population response Michael C. Madden1 and Brett Winters21US Environmental Protection Agency and 2University of North Carolina Human Studies Facility, Chapel Hill, North Carolina, USA Studies involving collection and...

  11. Whole-Body versus Local DXA-Scan for the Diagnosis of Osteoporosis in COPD Patients

    NARCIS (Netherlands)

    Graat-Verboom, L.; Spruit, M.A.; van den Borne, B.E.; Smeenk, F.W.; Wouters, E.F.M.

    2010-01-01

    Background. Osteoporosis is an extrapulmonary effect of chronic obstructive pulmonary disease (COPD). Diagnosis of osteoporosis is based on BMD measured by DXA-scan. The best location for BMD measurement in COPD has not been determined. Aim of this study was to assess whole-body BMD and BMD of the

  12. Effect of bifidobacteria implantation on the survival time of whole-body irradiated mice

    International Nuclear Information System (INIS)

    Yokokura, Teruo; Onoue, Masaharu; Mutai, Masahiko

    1980-01-01

    Letahl dose (2 KR) of gamma-ray was irradiated on the whole bodies of mice. Survival time after irradiation was significantly longer in mice with administration of both Bifidobacterium breve YIT 4008 and transgalactosyl oligosaccharide than in mice with administration of either of the two or nothing. (Tsunoda, M.)

  13. The control of equilibrium in bimanual, whole-body lifting tasks : a biomechanical approach

    NARCIS (Netherlands)

    Commissaris, D.A.C.M.

    1997-01-01

    The issues addressed in this thesis concern the control of equilibrium in a bimanual, wholebody lifting task. This task comprises the forward bending of the trunk and the lowering of the whole body to grasp an object with two hands, followed by the lifting of the object to waist or chest level.

  14. Comparative evaluation of nose-only vs. whole-body inhalation exposures for rats

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, H C; Snipes, M B; Eidson, A F; Hobbs, C H

    1988-12-01

    Two types of rat exposure chambers, nose-only and whole-body chambers, were evaluated simultaneously for the temporal and spatial distribution of the same test aerosols within the chambers, both with and without animals present. Results indicated that both types of exposure chambers performed well, with coefficients of variation less than 10% for both temporal and spatial variations. (author)0.

  15. Comparative evaluation of nose-only vs. whole-body inhalation exposures for rats

    International Nuclear Information System (INIS)

    Yeh, H.C.; Snipes, M.B.; Eidson, A.F.; Hobbs, C.H.

    1988-01-01

    Two types of rat exposure chambers, nose-only and whole-body chambers, were evaluated simultaneously for the temporal and spatial distribution of the same test aerosols within the chambers, both with and without animals present. Results indicated that both types of exposure chambers performed well, with coefficients of variation less than 10% for both temporal and spatial variations. (author)

  16. Whole body effective dose measurements in a fan beam bone mineral densitometer, Lunar expert

    Energy Technology Data Exchange (ETDEWEB)

    Sathiakumar, C.; Griffiths, M.; Cross, P.; Pocock, N.; Freund, J. [St Vincents Hospital, Sydney, NSW (Australia) Department of Nuclear Medicine; Kron, T.; Duggan, L. [Newcastle Mater Misericordiae Hospital, Newcastle, NSW (Australia). Department of Radiation Oncology; Holley, L. [University of Technology, Sydney, NSW (Australia). Department of Health Services

    1998-06-01

    Full text: The most recent generation of DXA machines employ a fan beam geometry and high resolution imaging detector, resulting in decreased scanning time and increased image resolution compared to previous rectilinear scanners, but with higher radiation burden to the patient because of an increasing number of bone mineral density scans, it was felt that independent evaluation of the radiation dose was necessary. The whole body effective dose for an AP lumbar spine scan and femur scan using the EXPERT bone densitometer was calculated for the fast and turbo scanning modes, using thermoluminescence dosimetry (TLD). A method was developed to determine the absorbed dose of the irradiated volume of an organ by summing the dose for each of the coronal areas, which results in a volume dose. The Whole Body Effective dose for AP lumbar spine fast scanning mode is 84.1 {mu}Sv and turbo scanning mode is 56.4 {mu}Sv. The Whole Body Effective dose for femur fast scanning mode is 6.6 {mu}Sv and turbo scanning mode is 4.2 {mu}Sv, with no ovary exposure. A theoretical method has been developed to calculate the organ dose from which whole body effective dose was calculated

  17. Early and late allergic reaction in the nose assessed by whole body plethysmography

    NARCIS (Netherlands)

    deBruinWeller, MS; Weller, FR; Scholte, A; Rijssenbeek, LHM; vanderBaan, S; Bogaard, JM; deMonchy, JGR

    Physiological changes during late phase nasal responses after allergen challenge are difficult to establish and different criteria are used for the definition of a positive late phase nasal reaction. The objective of this study was to assess the value of whole body plethysmography in detecting

  18. Whole-Body versus Local DXA-Scan for the Diagnosis of Osteoporosis in COPD Patients

    Directory of Open Access Journals (Sweden)

    Lidwien Graat-Verboom

    2010-01-01

    Full Text Available Background. Osteoporosis is an extrapulmonary effect of chronic obstructive pulmonary disease (COPD. Diagnosis of osteoporosis is based on BMD measured by DXA-scan. The best location for BMD measurement in COPD has not been determined. Aim of this study was to assess whole-body BMD and BMD of the hip and lumbar spine (local DXA in COPD patients and compare the prevalence of osteoporosis at these locations. Methods. Whole body as well as local DXA-scan were made in 168 COPD patients entering pulmonary rehabilitation. Patient-relevant characteristics were assessed. Prevalence of osteoporosis was determined. Characteristics of patients without osteoporosis were compared to patients with osteoporosis on local DXA. Results. A higher prevalence of osteoporosis was found using local DXA compared to whole-body DXA (39% versus 21%. One quarter of patients without osteoporosis on whole body-DXA did have osteoporosis on local DXA. Significant differences in patient characteristics between patients without osteoporosis based on both DXA measurements and patients with osteoporosis based on local DXA only were found. Conclusions. DXA of the hip and lumbar spine should be made to assess bone mineral density in COPD patients. The lowest T-score of these locations should be used to diagnose osteoporosis.

  19. Trial making of a positive drawing phantom and its application to whole-body imaging devices

    International Nuclear Information System (INIS)

    Saegusa, Kenji; Arimizu, Noboru; Nakata, Tsuneo; Toyama, Haruo; Shiina, Isamu.

    1980-01-01

    In whole-body RI imaging, there are more instances of the positive pictures detecting the radioisotopes accumulating in morbid positions, such as Tc-99m bone scanning. The phantoms used to mutually compare RI imaging devices and to test their performance employ negative drawing targets embedded rather than positive ones. A simple positive drawing phantom has been made for trial, and applying this to whole-body scanning devices, the performance and the target drawing ability under different scanning conditions were comparatively examined. Though similar to Rollo's phantom, the phantom made for positive drawing uses acryl plate for its outer structure and target portions. The positive targets are cylindrical, and the diameters are 2, 4, 6, 8, 10, and 20 mm, and the subject contrasts are 5, 2, 1, 0.5 and 0.2. The aqueous solution of Tc-99m of about 2 mCi was injected into the phantom, and this was scanned with a whole-body camera and a multi-detector type whole-body scanner. With the phantom pictures close to actual clinical condition, the positive drawing phantom is conveniently capable of comparing the respective imaging devices for intended purposes. (J.P.N.)

  20. Effect of whole-body vibration on muscle strength, spasticity, and ...

    African Journals Online (AJOL)

    CP) and is characterized by spasticity and muscle weakness of both lower limbs resulting in decreased walking ability. The purpose of this study was to evaluate the effect of whole body vibration (WBV) training on muscle strength, spasticity, and ...

  1. Amino acid metabolism and whole-body protein turnover in lambs ...

    African Journals Online (AJOL)

    The effect of protein supplementation of a wheat straw diet on the metabolism of lysine, leucine, methionine and urea, and on whole-body protein turnover rate was investigated in lambs. The metabolism of lysine and leucine is reported elsewhere (Cronje et aI., 1992); in this paper methionine metabolism is discussed, and ...

  2. Relevance of whole body vibration exercise in sport: a short review ...

    African Journals Online (AJOL)

    Background: Whole body vibration exercise (WBVE) has been used as a safe and accessible exercise and important reviews have been published about the use of this exercise to manage diseases and to improve physical conditions of athletes The aim of this paper is to highlight the relevance of WBVE to soccer players, ...

  3. Use of extremity insulation during whole body hyperthermia to reduce temperature nonuniformity

    International Nuclear Information System (INIS)

    Thrall, D.E.; Page, R.L.

    1987-01-01

    The author previously documented during whole body hyperthermia in dogs using a radiant heating device that temperature at superficial sites, including tibial bone marrow, falls below systemic arterial temperature during the plateau phase of heating. This may be due to direct heat loss to the environment. Sites where temperature is lower than systemic arterial temperature during the plateau phase may become sanctuary sites where tumor deposits are spared because they do not receive the prescribed thermal dose. In an attempt to decrease temperature nonuniformity and increase thermal dose delivered to such superficial sites, extremity insulation has been employed during whole body hyperthermia in dogs. The author measured temperature at cutaneous and subcutaneous sites and within tibial bone marrow in insulated and noninsulated extremities of dogs undergoing whole body hyperthermia in the radiant heating device. The author found that extremity insulation is effective in reducing extremity temperature nonuniformity. Specific results are presented. Extremity insulation may be necessary during whole body hyperthermia to assure that extremity tumor deposits receive a thermal dose similar to that prescribed for the entire body

  4. Circumference estimation using 3D-whole body scanners and shadow scanner

    NARCIS (Netherlands)

    Daanen, H.A.M.

    1998-01-01

    Clothing designers and manufacturers use traditional body dimensions as their basis. When 3D-whole body scanners are introduced to determine the body dimensions, a conversion has to be made, since scan determined circumference measures are slightly larger than the traditional values. This pilot

  5. Aspects of the engineering design of whole-body nuclear magnetic resonance machines

    International Nuclear Information System (INIS)

    Young, I.R.; Collins, A.G.; Hall, A.S.; Harman, R.R.; Butson, P.C.; Gilderdale, D.J.

    1987-01-01

    The paper on whole-body nuclear magnetic resonance machines reviews the basic physics very briefly, then examines the design requirements and engineering constraints for the major components of such a system. The paper concludes with a brief resume of the techniques used, and a short presentation of the type of results that are achieved. (author)

  6. Effects of whole body cryotherapy and cold water immersion on knee skin temperature

    OpenAIRE

    Costello, J. T.; Donnelly, A. E.; Karki, A.; Selfe, J.

    2014-01-01

    This study sought to a) compare and contrast the effect of 2 commonly used cryotherapy treatments, 4 min of −110°C whole body cryotherapy and 8°C cold water immersion, on knee skin temperature and b) establish whether either protocol was capable of achieving a skin temperature (

  7. Evaluation of Massey Ferguson Model 165 Tractor Drivers exposed to whole-body vibration

    Directory of Open Access Journals (Sweden)

    P. Nassiri

    2013-12-01

    Conclusion: This study shows that the need to provide intervention , controlling and managing measures to eliminate or reduce exposure to whole body vibration among tractor drivers its necessary. And, preventing main disorder Including musculoskeletal disorders, discomfort and early fatigue is of circular importance. More studies are also necessary to identify the sources of vibration among various of tractors.

  8. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto

    1997-01-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  9. Scaling of lifting forces in relation to object size in whole body lifting

    NARCIS (Netherlands)

    Kingma, I.; van Dieen, J.H.; Toussaint, H.M.

    2005-01-01

    Subjects prepare for a whole body lifting movement by adjusting their posture and scaling their lifting forces to the expected object weight. The expectancy is based on visual and haptic size cues. This study aimed to find out whether lifting force overshoots related to object size cues disappear or

  10. Monte Carlo calculation of efficiencies of whole-body counter, by microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computer programming using the Monte Carlo method for calculation of efficiencies of whole-body counting of body radiation distribution is presented. An analytical simulator (for man e for child) incorporated with 99m Tc, 131 I and 42 K is used. (M.A.C.) [pt

  11. Early and late allergic reaction in the nose assessed by whole body plethysmography

    NARCIS (Netherlands)

    de Bruin-Weller, M. S.; Weller, F. R.; Scholte, A.; Rijssenbeek, L. H.; van der Baan, S.; Bogaard, J. M.; de Monchy, J. G.

    1996-01-01

    Physiological changes during late phase nasal responses after allergen challenge are difficult to establish and different criteria are used for the definition of a positive late phase nasal reaction. The objective of this study was to assess the value of whole body plethysmography in detecting

  12. Evaluation of whole-body MR to CT deformable image registration

    NARCIS (Netherlands)

    Akbarzadeh, A.; Gutierrez, D.; Baskin, A.; Ay, M. R.; Ahmadian, A.; Alam, N. Riahi; Loevblad, K. O.; Zaidi, H.

    2013-01-01

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based

  13. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1997-10-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  14. Whole body MRI in the diagnosis of chronic recurrent multifocal osteomyelitis.

    LENUS (Irish Health Repository)

    Kennedy, M T

    2012-06-01

    Chronic recurrent multifocal osteomyelitis (CRMO) is a diagnosis of exclusion primarily in children and adolescents. As part of the essential criteria for the diagnosis of CRMO, multifocal lesions must be identified. We present the case of an 11-year-old boy with CRMO, whose diagnosis was facilitated by the use of whole body magnetic resonance imaging (WBMR), but not isotope bone scanning.

  15. Whole-body CO2 production as an index of the metabolic response to sepsis

    Science.gov (United States)

    Whole-body carbon dioxide (CO2) production (RaCO2) is an index of substrate oxidation and energy expenditure; therefore, it may provide information about the metabolic response to sepsis. Using stable isotope techniques, we determined RaCO2 and its relationship to protein and glucose metabolism in m...

  16. Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET

    NARCIS (Netherlands)

    Karakatsanis, Nicolas A.; Zhou, Yun; Lodge, Martin A.; Casey, Michael E.; Wahl, Richard L.; Zaidi, Habib; Rahmim, Arman

    2015-01-01

    We recently developed a dynamic multi-bed PET data acquisition framework to translate the quantitative benefits of Patlak voxel-wise analysis to the domain of routine clinical whole-body (WB) imaging. The standard Patlak (sPatlak) linear graphical analysis assumes irreversible PET tracer uptake,

  17. Whole-body γ-irradiation effects on catecholamine concentration in animal tissues

    International Nuclear Information System (INIS)

    Makashev, Zh.K.; Uteshev, T.A.; Abylaev, Zh. A.; Zhurnist, A.G.

    2003-01-01

    On the whole-body gamma-radiation activity in the exchanges of catecholamines (adrenalin and non-adrenalin) and their predecessors (dopamine and DOPA) in the rats tissue organism, indicate the infringement of irradiated animals in different links of biological synthesis the bio-gen amines in different phases of the radiation: DOPA→dopamine, dopamine→adrenalin, adrenalin→non-adrenalin. (author)

  18. Head Exposure to Cold during Whole-Body Cryostimulation: Influence on Thermal Response and Autonomic Modulation

    Science.gov (United States)

    Louis, Julien; Schaal, Karine; Bieuzen, François; Le Meur, Yann; Filliard, Jean-Robert; Volondat, Marielle; Brisswalter, Jeanick; Hausswirth, Christophe

    2015-01-01

    Recent research on whole-body cryotherapy has hypothesized a major responsibility of head cooling in the physiological changes classically reported after a cryostimulation session. The aim of this experiment was to verify this hypothesis by studying the influence of exposing the head to cold during whole-body cryostimulation sessions, on the thermal response and the autonomic nervous system (ANS). Over five consecutive days, two groups of 10 participants performed one whole-body cryostimulation session daily, in one of two different systems; one exposing the whole-body to cold (whole-body cryostimulation, WBC), and the other exposing the whole-body except the head (partial-body cryostimulation, PBC).10 participants constituted a control group (CON) not receiving any cryostimulation. In order to isolate the head-cooling effect on recorded variables, it was ensured that the WBC and PBC systems induced the same decrease in skin temperature for all body regions (mean decrease over the 5 exposures: -8.6°C±1.3°C and -8.3±0.7°C for WBC and PBC, respectively), which persisted up to 20-min after the sessions (P20). The WBC sessions caused an almost certain decrease in tympanic temperature from Pre to P20 (-0.28 ±0.11°C), while it only decreased at P20 (-0.14±0.05°C) after PBC sessions. Heart rate almost certainly decreased after PBC (-8.6%) and WBC (-12.3%) sessions. Resting vagal-related heart rate variability indices (the root-mean square difference of successive normal R-R intervals, RMSSD, and high frequency band, HF) were very likely to almost certainly increased after PBC (RMSSD:+49.1%, HF: +123.3%) and WBC (RMSSD: +38.8%, HF:+70.3%). Plasma norepinephrine concentration was likely increased in similar proportions after PBC and WBC, but only after the first session. Both cryostimulation techniques stimulated the ANS with a predominance of parasympathetic tone activation from the first to the fifth session and in slightly greater proportion with WBC than PBC

  19. Whole-Body MR Imaging Including Angiography: Predicting Recurrent Events in Diabetics.

    Science.gov (United States)

    Bertheau, Robert C; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M; Parhofer, Klaus G; Kauczor, Hans-Ulrich; Schoenberg, Stefan O; Weckbach, Sabine; Schlett, Christopher L

    2016-05-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30%) developed one, 8 (13%) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75%, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63%, p = 0.001), carotid artery stenosis (11/17/63%, p = 0.005), peripheral artery stenosis (26/56/88%, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. • Patients with long-standing diabetes mellitus are at high risk for recurrent events. • Whole-body MRI predicts occurrence of recurrent events independently of clinical characteristics. • The vessel score derived from whole-body angiography is a good general risk-marker. • Whole-body MRI may also provide organ-specific risk assessment. • Current findings may indicate benefits of

  20. USTUR WHOLE BODY CASE 0269: DEMONSTRATING EFFECTIVENESS OF I.V. CA-DTPA FOR PU

    Energy Technology Data Exchange (ETDEWEB)

    James, Anthony C.; Sasser , Lyle B.; Stuit, Dorothy B.; Glover, Samuel E.; Carbaugh, Eugene H.

    2008-01-28

    This whole body donation case (USTUR Registrant) involved a single acute inhalation of an acidic Pu(NO3)4 solution in the form of an aerosol ‘mist.’ Chelation treatment with i.v. Ca-EDTA was initiated on the day of the intake, and continued intermittently over 6 months. After 2½ years with no further treatment, a course of i.v. Ca-DTPA was administered. A total of 400 measurements of 239+240Pu excreted in urine were recorded; starting on the first day (both before and during the initial Ca-EDTA chelation), and continuing for 37 years. This sampling included all intervals of chelation. In addition, 91 measurements of 239+240Pu-in-feces were recorded over this whole period. The Registrant died about 38 years after the intake, at age 79 y, with extensive carcinomatosis secondary to adenocarcinoma of the prostate gland. At autopsy, all major soft tissue organs were harvested for radiochemical analyses of their 238Pu, 239+240Pu and 241Am content. Also, all types of bone (comprising about half the skeleton) were harvested for radiochemical analyses, as well as samples of skin, subcutaneous fat and muscle. This comprehensive dataset has been applied to derive ‘chelation-enhanced’ transfer rates in the ICRP Publication 67 plutonium biokinetic model, representing the behaviour of blood-borne and tissue-incorporated plutonium during intervals of therapy. The resulting model of the separate effects of i.v. Ca-EDTA and Ca-DTPA chelation shows that the therapy administered in this case succeeded in reducing substantially the long-term burden of plutonium in all body organs, except for the lungs. The calculated reductions in organ content at the time of death are approximately 40% for the liver, 60% for other soft tissues (muscle, skin, glands, etc.), 50% for the kidneys, and 50% for the skeleton. Essentially all of the substantial reduction in skeletal burden occurred in trabecular bone. This modeling exercise demonstrated that 3-y-delayed Ca-DTPA therapy was as

  1. Ustur whole body case 0269: demonstrating effectiveness of i.v. CA-DTPA for Pu

    Energy Technology Data Exchange (ETDEWEB)

    James, A.C.; Sasser, L.B.; Stuit, D.B. [US Transuranium and Uranium Registries, College of Pharmacy, Washington State University, 1845 Terminal Drive, Suite 201, Richland, WA 99354 (United States); Glover, S.E. [Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, 598 Rhodes Hall, Cincinnati, OH 45221 (United States); Carbaugh, E.H. [Pacific Northwest National Laboratory, PO Box 999, Richland, WA 99354 (United States)

    2007-07-01

    This whole body donation case (USTUR Registrant) involved a single acute inhalation of an acidic Pu(NO{sub 3}){sub 4} solution in the form of an aerosol 'mist'. Chelation treatment with intravenously (i.v.) Ca-EDTA was initiated on the day of the intake, and continued intermittently over 6 months. After 2.5 y with no further treatment, a course of i.v. Ca-DTPA was administered. A total of 400 measurements of {sup 239+240}Pu excreted in urine were recorded; starting on the first day (both before and during the initial Ca-EDTA chelation) and continuing for 37 y. This sampling included all intervals of chelation. In addition, 91 measurements of {sup 239+240}Pu-in-feces were recorded over this whole period. The Registrant died about 38 y after the intake, at age 79 y, with extensive carcinomatosis secondary to adenocarcinoma of the prostate gland. At autopsy, all major soft tissue organs were harvested for radiochemical analyses of their {sup 238}Pu, {sup 239+240}Pu and {sup 241}Am content. Also, all types of bone (comprising about half the skeleton) were harvested for radiochemical analyses, as well as samples of skin, subcutaneous fat and muscle. This comprehensive data set has been applied to derive 'chelation-enhanced' transfer rates in the ICRP Publication 67 plutonium biokinetic model, representing the behaviour of blood-borne and tissue-incorporated plutonium during intervals of therapy. The resulting model of the separate effects of i.v. Ca-EDTA and Ca-DTPA chelation shows that the therapy administered in this case succeeded in reducing substantially the long-term burden of plutonium in all body organs, except for the lungs. The calculated reductions in organ content at the time of death are {approx}40% for the liver, 60% for other soft tissues (muscle, skin, glands, etc.), 50% for the kidneys and 50% for the skeleton. Essentially, all of the substantial reduction in skeletal burden occurred in trabecular bone. This modelling exercise

  2. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  3. Quantitative analysis of skin reaction by reflectance spectrophotometer. Acute reaction following proton therapy

    International Nuclear Information System (INIS)

    Kawashima, Mitsuhiko; Okumura, Toshiyuki; Tatsuzaki, Hideo; Tsuji, Hiroshi; Tsujii, Hirohiko.

    1994-01-01

    Acute reactions induced by proton irradiation were measured using a reflectance spectrophotometer, which is commonly used in the printing and textile industries. In this method, the skin color was expressed by three parameters, lightness (L * ), chroma (C * ) and hue (h). At first, in order to evaluate the accuracy of this spectrophotometer, the skin color of a normal volunteer was measured 100 times. The values of the three parameters for normal skin were as follows (mean values and standard deviation), L * : 68.64±0.29, C * : 19.08±0.13, h: 69.41±0.76. The standard deviations with regard to L * and h, were considered to be sufficiently small when compared with the changes of these parameters (prefix: Δ) in the irradiated sites (ΔL * * and h values significantly decreased with time, and the L * values were highly correlated with elapsed treatment days. The h values had a relatively low linear correlation compared with L * . The C * values had no trends as the treatment period was extended. Among these parameters, the L * values were the most valuable for assessment of proton-induced skin reactions, and it was suggested that the L * values measured with this spectrophotometer were a useful index for showing biological effects induced by proton irradiation. Further experiments are needed to apply this method to quantify the biological effects induced by other forms of ionizing radiation. (author)

  4. Acute hematological tolerance to multiple fraction, whole body, low dose irradiation in an experimental murine system

    International Nuclear Information System (INIS)

    Melamed, J.S.; Chen, M.G.; Brown, J.W.; Katagiri, C.A.

    1980-01-01

    Using a dose fractionation scheme patterned after the current regimen for treatment of disseminated non-Hodgkin lymphoma, the authors studied the effects of irradation on progenitor and effector cells for hematopoiesis in five-month-old BC3F 1 mice. Fractions of 20 or 50 rad (0.2 or 0.5 Gy) total body irradation were given twice weekly to a final total dose of 200 or 500 rad (2 or 5 Gy), respectively. Weekly assays revealed a marked, sustained depression of stem cell activity, measured as numbers of spleen colony-forming units (CFU-S) and in vitro colony-forming cells (CFU-C), without corresponding depression of effector cells (red and white cells, and platelets). The lack of correlation between numbers of stem cells and peripheral elements is relevant to clinical assessment of marrow reserve

  5. C-fos protein expression in central nervous system. Effects of acute whole-body irradiation

    International Nuclear Information System (INIS)

    Martin, C.; Chollat, S.; Mahfoudi, H.; Lambert, F.; Baille Le Crom, V.; Fatome, M.

    1995-01-01

    Study of c-Fos protein expression in the rat striatum after gamma or (neutron-gamma) irradiation was carried on. c-Fos protein is expressed one hour after gamma exposure at the dose of 15 Gy but specificity of the response must be verified. (author)

  6. Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI).

    LENUS (Irish Health Repository)

    Gleeson, T G

    2009-03-01

    The aim of the study is to assess the feasibility of whole-body low-dose computed tomography (WBLDCT) in the diagnosis and staging of multiple myeloma and compare to skeletal survey (SS), using bone marrow biopsy and whole-body magnetic resonance imaging (WBMRI; where available) as gold standard.

  7. USE OF WHOLE-BODY VIBRATION AS A MODE OF WARMING UP BEFORE COUNTER MOVEMENT JUMP

    Directory of Open Access Journals (Sweden)

    Enrique G. Artero

    2007-12-01

    results are presented jointly (Figure 1.Reports concerning acute effects of WBV on jump performance yield conflicting results. Transient benefits of 2.5, 4 and 8 % in CMJ height has been reported after 4 min (Torvinen et al., 2002a, 10 min (Bosco et al., 2000 and 5 min (Cochrane and Stannard, 2005 of WBV stimulus, respectively. The lack of improvement in our study may be partially explained by the time elapsed between the vibration stimulus and the jump test, since our subjects performed the CMJ immediately after the WBV exposure. The different training level of the participants may also explain discrepancies among studies, as our subjects were not engaged in any regular exercise practice. It has been reported that elite athletes may obtain more benefits from WBV than amateur athletes do (Issurin and Tenenbaum, 1999. In agreement with our results, other studies did not show improvement on CMJ performance after a single bout of WBV (Cormie et al., 2006; Rittweger et al., 2003; Torvinen et al., 2002b. Compared with our results, Cormie et al., 2006 did not find an impairment of CMJ performance immediately after a single WBV bout of 30 s, which may be associated with their shorter WBV stimulus (30 s, the interval actually elapsed between WBV and CMJ test, and the higher training level of their participants.In summary, whole-body vibration combined with voluntary contractions does not seem to be a useful method for warming up before activities involving vertical jumps. At least one minute interval recovery should be allowed when using WBV in a range of 20-30 Hz and 90 or 120 s if maximal jump performance is required.AcknowledgmentThis study was conducted without any conflict of interest, without financial assistance, and supported by grants from the Consejo Superior de Deportes (109/UPB31/03, 13/UPB20/04, the Spanish Ministry of Education and Science (AP2003-2128, AP-2004-2745; AP2005-3827; AP2005-4358 and the HELENA study (European Community Sixth RTD Framework Programme

  8. Conversion of a whole-body counter into a low-level whole-body scanning system controlled by a process computer

    International Nuclear Information System (INIS)

    Hamann, C.M.

    1976-01-01

    The report outlines the status of a research project in which a whole body counter with fixed geometries is converted into a scanning type system. The purpose of the project is the development of an adaptive system controlled by a process computer. The home-made scanning mechanics is explained, and a description is given of the advantages and the problems inherent in the application of step motors. For economic reasons no CAMAC system was purchased; instead, interfaces from and to the computer were designed which allowed the process periphery to be connected and operated. The inexpensive and relatively simple home-made designs are outlined; the example quoted refers to the conversion of a teletype output into a fast electronic data interface. (orig./ORU) [de

  9. The influence of whole-body vibration on creatine kinase activity and jumping performance in young basketball players.

    Science.gov (United States)

    Fachina, Rafael; da Silva, Antônio; Falcão, William; Montagner, Paulo; Borin, João; Minozzo, Fábio; Falcão, Diego; Vancini, Rodrigo; Poston, Brach; de Lira, Claudio

    2013-12-01

    To quantify creatine kinase (CK) activity changes across time following an acute bout of whole-body vibration (WBV) and determine the association between changes in CK activity and jumping performance. Twenty-six elite young basketball players were assigned to 3 groups: 36-Hz and 46-Hz vibration groups (G36 and G46, respectively) and a control group. The study quantified CK activity and jumping performance following an acute bout of WBV at 2 vibration frequencies. Both WBV groups performed a protocol that consisted of 10 sets of 60 s of WBV while standing on a vibration plate in a quarter-squat position. CK activity, countermovement jumps (CMJ), and squat jumps (SJ) were measured immediately before and 24 hr and 48 hr after WBV. In addition, CMJ and SJ were also measured 5 min after WBV. CK activity was statistically significantly increased 24 hr following WBV in G36 and G46. At 48 hr after WBV, CK activity was similar to baseline levels in G36 but remained statistically significantly above baseline levels in G46. The CMJ and SJ heights were statistically significantly decreased at 5 min following the protocol for both WBV groups. Overall, the changes in CK activity did not present a strong relationship with the changes in jump heights for any of the comparisons. These findings suggest that WBV protocols with such characteristics may not cause excessive muscle damage and may partly explain why many WBV training studies have failed to elicit increases in strength performance.

  10. Computational anatomy based on whole body imaging basic principles of computer-assisted diagnosis and therapy

    CERN Document Server

    Masutani, Yoshitaka

    2017-01-01

    This book deals with computational anatomy, an emerging discipline recognized in medical science as a derivative of conventional anatomy. It is also a completely new research area on the boundaries of several sciences and technologies, such as medical imaging, computer vision, and applied mathematics. Computational Anatomy Based on Whole Body Imaging highlights the underlying principles, basic theories, and fundamental techniques in computational anatomy, which are derived from conventional anatomy, medical imaging, computer vision, and applied mathematics, in addition to various examples of applications in clinical data. The book will cover topics on the basics and applications of the new discipline. Drawing from areas in multidisciplinary fields, it provides comprehensive, integrated coverage of innovative approaches to computational anatomy. As well,Computational Anatomy Based on Whole Body Imaging serves as a valuable resource for researchers including graduate students in the field and a connection with ...

  11. Prolonged bed rest decreases skeletal muscle and whole body protein synthesis

    Science.gov (United States)

    Ferrando, A. A.; Lane, H. W.; Stuart, C. A.; Davis-Street, J.; Wolfe, R. R.

    1996-01-01

    We sought to determine the extent to which the loss of lean body mass and nitrogen during inactivity was due to alterations in skeletal muscle protein metabolism. Six male subjects were studied during 7 days of diet stabilization and after 14 days of stimulated microgravity (-6 degrees bed rest). Nitrogen balance became more negative (P protein synthesis (PS; P protein also decreased by 46% (P protein breakdown and inward transport. Whole body protein synthesis determined by [15N]alanine ingestion on six subjects also revealed a 14% decrease (P protein breakdown change significantly. These results indicate that the loss of body protein with inactivity is predominantly due to a decrease in muscle PS and that this decrease is reflected in both whole body and skeletal muscle measures.

  12. Development of personnel dose control system and whole body counter system

    International Nuclear Information System (INIS)

    Ooki, Yasushi; Harato, Kenji

    2005-01-01

    We delivered Personnel Dose Control System to Higashidohri nuclear plant of Tohoku Electric Power Company, in November 2004. In this system development, we automated the registration of radiation worker with close link between this system and Whole Body Counter System. In addition, this system enables the user to reduce workload for accumulation and notification of personal exposure data, because we adopted the system to extract the data effectively operating the terminal PC which the associate company gets ready in their office. We also delivered Whole body Counter System in December 2004, which was developed to measure internal exposure without feeling of oppression in chair-style device for the first time in Japan. This system enables non-operator system for measurement allowing workers to operate by themselves. (author)

  13. Measurement of whole-body human centers of gravity and moments of inertia.

    Science.gov (United States)

    Albery, C B; Schultz, R B; Bjorn, V S

    1998-06-01

    With the inclusion of women in combat aircraft, the question of safe ejection seat operation has been raised. The potential expanded population of combat pilots would include both smaller and larger ejection seat occupants, which could significantly affect seat performance. The method developed to measure human whole-body CG and MOI used a scale, a knife edge balance, and an inverted torsional pendulum. Subjects' moments of inertia were measured along six different axes. The inertia tensor was calculated from these values, and principal moments of inertia were then derived. Thirty-eight antropometric measurements were also taken for each subject to provide a means for direct correlation of inertial properties to body dimensions and for modeling purposes. Data collected in this study has been used to validate whole-body mass properties predictions. In addition, data will be used to improve Air Force and Navy ejection seat trajectory models for the expanded population.

  14. Determination of iron absorption and excretion by whole-body counting

    International Nuclear Information System (INIS)

    Hollard, D.; Benabid, Y.; Berard, M.; Bonnin, J.; Darnault, J.; Millet, M.

    1969-01-01

    Using a whole-body counter, the authors have studied 59 Fe absorption and loss in 8 normal subjects and in 30 iron deficient patients. Results showed that whole-body counting provided an excellent and simple method for iron retention measurements, obviating many inaccuracies of previous technic. Normal absorption of radio iron with this procedure has ranged from 9 per cent to 20 per cent of the administered tracer in normal subjects, with a mean of 15 per cent. A significant increase in 59 Fe absorption was noted in 21 iron-deficient patients in whom the retention ranged from 40 to 100 per cent. However, 3 iron-deficient patients were found to have low absorption, and their severe iron deficiency could be correlated with this defect in absorption. This method permits also the determination of the rate of iron excretion during the following months and therefore the study of the mechanism of some pathological loss. (authors) [fr

  15. A review of whole-body counting techniques appropriate to the study of gastrointestinal absorption

    International Nuclear Information System (INIS)

    Boddy, K.

    1976-01-01

    The wide range of whole-body counters in use for, or applicable to, the study of gastrointestinal absorption is reviewed. Shielded-room or high-sensitivity shadow-shield counters will generally be required only when there is a separate need to measure total body potassium or in studies involving pregnancy or children. For measuring gastrointestinal absorption per se, it is concluded that very simple whole-body counters of the shadow-shield or partial-shield type are usually satisfactory. These systems are of lower cost, and an economic justification for their use is derived by comparing their costs with those of hospitalizing patients for alternative investigations of gastrointestinal absorption. A resume of the general methodology is presented and some operational features and precautions are described. (author)

  16. Whole body and tissue blood volumes of two strains of rainbow trout (Oncorhynchus mykiss)

    Science.gov (United States)

    Gingerich, W.H.; Pityer, R.A.; Rach, J.J.

    1990-01-01

    1. Estimates of apparent packed cell, plasma and total blood volumes for the whole body and for 13 selected tissues were compared between Kamloops and Wytheville strains of rainbow trout (Oncorhynchus mykiss) by the simultaneous injection of two vascular tracers, radiolabeled trout erythrocytes (51Cr-RBC) and radioiodated bovine serum albumin (125I-BSA).2. Whole body total blood volume, plasma volume and packed cell volume were slightly, but not significantly greater in the Wytheville trout, whereas, the apparent plasma volumes and total blood volumes in 4 of 13 tissues were significantly greater in the Kamloops strain.3. Differences were most pronounced in highly perfused organs, such as the liver and kidney and in organs of digestion such as the stomach and intestines.4. Differences in blood volumes between the two strains may be related to the greater permeability of the vascular membranes in the Kamloops strain fish.

  17. Whole-body kinetics and dosimetry of cis-4-[18F]fluoro-l-proline

    International Nuclear Information System (INIS)

    Boerner, Anne R.; Langen, Karl-J.; Herzog, Hans; Hamacher, Kurt; Mueller-Mattheis, Volker; Schmitz, Thomas; Ackermann, Rolf; Coenen, Heinz H.

    2001-01-01

    The whole-body distribution of 4-cis[ 18 F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 μGy/MBq). The effective dose according to ICRP 60 was 15.1 μSv/MBq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro

  18. Whole-body kinetics and dosimetry of cis-4-[{sup 18}F]fluoro-l-proline

    Energy Technology Data Exchange (ETDEWEB)

    Boerner, Anne R.; Langen, Karl-J. E-mail: k.j.langen@fz-juelich.de; Herzog, Hans; Hamacher, Kurt; Mueller-Mattheis, Volker; Schmitz, Thomas; Ackermann, Rolf; Coenen, Heinz H

    2001-04-01

    The whole-body distribution of 4-cis[{sup 18}F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 {mu}Gy/MBq). The effective dose according to ICRP 60 was 15.1 {mu}Sv/MBq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro.

  19. Whole-body kinetics and dosimetry of cis-4-[(18)F]fluoro-L-proline.

    Science.gov (United States)

    Börner, A R; Langen, K J; Herzog, H; Hamacher, K; Müller-Mattheis, V; Schmitz, T; Ackermann, R; Coenen, H H

    2001-04-01

    The whole-body distribution of 4-cis[(18)F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 microGy/mbq). The effective dose according to ICRP 60 was 15.1 microSv/mbq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro.

  20. Chemical radioprotection to bone marrow stem cells after whole body gamma irradiation to mice

    Energy Technology Data Exchange (ETDEWEB)

    Dey, J.; Dey, T.B.; Ganguly, S.K.; Nagpal, K.K.; Ghose, A.

    1988-11-01

    Protection to mice bone marrow stem cells has been noted as early as two days after whole body gamma ray exposure by prior treatment with combination of hydroxytryptophan (HT) and one of the two thiol drugs viz., aminoethylisothiuronium bromide hydrobromide (AET) (20 mg/kg body weight) and B-mercaptopropionylglicine (MPG). The levels of protection to bone marrow stem cells thus obtained have been compared to that obtained by treating with the optimum radioprotecting dose of AET (200 mg/kg body weight). The study reports the bone marrow stem cells status after two days of 3 Gy, 5 Gy and 10 Gy whole body gamma irradiation in relation to the mentioned radioprotecting treatments as studied by spleen colony forming method.

  1. Whole-body retention of 60Co incorporated into a seaweed in rats

    International Nuclear Information System (INIS)

    Inaba, Jiro; Nishimura, Yoshikazu; Ichikawa, Ryushi

    1979-01-01

    The objective of this study is to compare whole-body retention in the rat of radiocobalt incorporated into a marine green alga with that of 60 Co in inorganic form. Ulva pertusa was incubated in aerated seawater containing 60 Co under fluorescent lamp for 7 days. The radioactive seaweed was homogenated and was given to rats via a stomach tube. The control group of rats was given 60 CoCl 2 with homogenate of non-radioactive seaweed. Whole-body retention of the radionuclide was determined by in vivo counting of the living animal. The result revealed that rats absorbed and retained much more 60 Co incorporated into the seaweed than 60 CoCl 2 . This fact should be taken into account in the estimation of internal dose due to radiocobalt released into marine environment. (author)

  2. Impact of whole-body rehabilitation in patients receiving chronic mechanical ventilation.

    Science.gov (United States)

    Martin, Ubaldo J; Hincapie, Luis; Nimchuk, Mark; Gaughan, John; Criner, Gerard J

    2005-10-01

    To evaluate the prevalence and magnitude of weakness in patients receiving chronic mechanical ventilation and the impact of providing aggressive whole-body rehabilitation on conventional weaning variables, muscle strength, and overall functional status. Retrospective analysis of 49 consecutive patients. Multidisciplinary ventilatory rehabilitation unit in an academic medical center. Forty-nine consecutive chronic ventilator-dependent patients referred to a tertiary care hospital ventilator rehabilitation unit. None. Patients were 58 +/- 7 yrs old with multiple etiologies for respiratory failure. On admission, all patients were bedridden and had severe weakness of upper and lower extremities measured by a 5-point muscle strength score and a 7-point Functional Independence Measurement. Postrehabilitation, patients had increases in upper and lower extremity strength (p respiratory muscle training with an improvement in strength, weaning outcome, and functional status. Whole-body rehabilitation should be considered a significant component of their therapy.

  3. Effects of whole body UV-irradiation on oxygen delivery from the erythrocyte

    International Nuclear Information System (INIS)

    Humpeler, E.; Mairbaeurl, H.; Hoenigsmann, H.

    1982-01-01

    In 16 healthy caucasian volunteers (mean age: 22.2 years) the influence of whole body UV-irradiation on the oxygen transport properties of erythrocytes was investigated. Four hours after irradiation with UV (using the minimal erythema dose, MED) no variation of haemoglobin concentration, hematocrit, mean corpuscular haemoglobin concentration, pH or standard bicarbonate could be found, whereas inorganic plasma phosphate (Psub(i)), calcium, the intraerythrocytic 2,3-diphosphoglycerate (2,3-DPG), the activity of erythrocytic phosphofructokinase (PFK) and pyruvatekinase (PK) increased significantly. The half saturation tension of oxygen (P 50 -value) tended to increase. The increase of Psub(i) causes - via a stimulation of the glycolytic pathway - an increase in 2,3-DPG concentration and thus results in a shift of the oxygen dissociation curve. It is therefore possible to enhance tissue oxygenation by whole body UV-irradiation. (orig.)

  4. Vestibular-somatosensory interactions: effects of passive whole-body rotation on somatosensory detection.

    Directory of Open Access Journals (Sweden)

    Elisa Raffaella Ferrè

    Full Text Available Vestibular signals are strongly integrated with information from several other sensory modalities. For example, vestibular stimulation was reported to improve tactile detection. However, this improvement could reflect either a multimodal interaction or an indirect interaction driven by vestibular effects on spatial attention and orienting. Here we investigate whether natural vestibular activation induced by passive whole-body rotation influences tactile detection. In particular, we assessed the ability to detect faint tactile stimuli to the fingertips of the left and right hand during spatially congruent or incongruent rotations. We found that passive whole-body rotations significantly enhanced sensitivity to faint shocks, without affecting response bias. Critically, this enhancement of somatosensory sensitivity did not depend on the spatial congruency between the direction of rotation and the hand stimulated. Thus, our results support a multimodal interaction, likely in brain areas receiving both vestibular and somatosensory signals.

  5. Bases for calibration of whole body counters using anthropomorphic physical simulators

    International Nuclear Information System (INIS)

    Dantas, Bernardo Maranhao

    1998-01-01

    The quantification of radionuclides in the human body can be carried out through in vivo measurements performed in facilities generically called whole body counters. The calibration of such units is usually done by using physical anthropomorphic phantoms, which can be defined as artificial structures with geometrical characteristics and attenuation properties similar to the living tissues. This work presents the development of the phantoms necessary to the monitoring of the internal contamination by the radionuclides manipulated in Brazil. It also presents the procedures for the calibration of the detectors used for the in vivo measurements. The developed phantoms are applied in the determination of radionuclides deposited in specific organs, such as Th-232 and Am-241 in the lungs and skull, isotopes of iodine in the thyroid and photon emitters in the energy range from 100 to 3000 keV in the whole body. (author)

  6. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  7. [Modeling of processes of heat transfer in whole-body hyperthermia].

    Science.gov (United States)

    Kinsht, D N

    2006-01-01

    The method of whole-body hyperthermia in which the body temperature for a short time reaches values up to 43-44 degrees C holds currently much promise. However, at body temperatures above 42 degrees C, the risks associated with the hemodynamic instability and the appearance of arrhythmia in the patient increase. A model of heat transfer has been created to increase the efficiency and safety of the immersion-convectional method of whole-body hyperthermia. This model takes into account changes in the skin blood flow and the dynamics of pulse rate depending on body temperature. The model of heat transfer adequately reflects processes of heating of the organism and can form a basis for the calculation of distribution of heat inside the organism.

  8. Effect of whole body irradiation on O2- production in polymorphonuclear leukocyte of guinea pig

    International Nuclear Information System (INIS)

    Niiya, Harutaka

    1987-01-01

    The capacity of superoxide anion production of polymorphonuclear leukocytes (PMNL) has been determined after whole body irradiation. A diminished capacity of superoxide anion production in the presence of opsonized zymosan was found in PMNL taken from guinea pigs irradiated in vivo with 5, 10, and 20 Gy. However, no such diminution was found after a dose of 2 Gy. On the other hand, levels of superoxide anion production stimulated by myristate, N-Formyl-Methionyl-Leucyl-Phenylalanine (FMLP), and Concanavalin A remained unchanged compared to the control. PMNL irradiated in vitro with 20 Gy had a capacity of superoxide anion production similar to that of the control samples in the presence of either opsonized zymosan or FMLP and myristate. These results suggest that the capacity of superoxide anion production stimulated by zymosan is damaged by whole body irradiation. (author)

  9. Improved quality of image got through whole-body CT scanner

    International Nuclear Information System (INIS)

    Asahina, Kiyotaka

    1980-01-01

    The quality of brain images taken with a whole-body CT scanner has so far been generally inferior in quality to those got through a CT scanner exclusively used for brains. In order to improve the whole-body CT scanner so as to get better brain image, its detection system has been made multichannel; the capacity of its X-ray tube, increased; and its software, innovated. As a result, the spatial resolution has been improved from 5.51 p/cm to 9.01 p/cm, the contrast resolution has been improved from 3.2 mm% to 1.5 mm%, with the noise maintained at 0.5%. In clinical examination, the image quality has been improved equally well for brains, abdomens and lungs. Especially high appreciation is given to the diagnosis information got through this new scanner. (author)

  10. The four-dimensional mouse whole-body phantoms and its application in medical imaging research

    International Nuclear Information System (INIS)

    Li Chongguo; Wu Dake

    2012-01-01

    Medical imaging simulation is a powerful tool for characterizing,evaluating,and optimizing medical imaging devices and techniques. A vital aspect of simulation is to have a realistic phantom or model of the subject's anatomy. Four-dimensional mouse whole-body phantoms provide realistic models of the mouse anatomy and physiology for imaging studies. When combined with accurate models for the imaging process,are capable of providing a wealth of realistic imaging data from subjects with various anatomies and motions (cardiac and respiratory) in health and disease. With this ability, the four-dimensional mouse whole-body phantoms have enormous potential to study the effects of anatomical, physiological and physical factors on medical and small animal imaging and to research new instrumentation, image acquisition strategies, image processing, reconstruction methods, image visualization and interpretation techniques. (authors)

  11. Whole body bone scintigraphy in tenofovir-related osteomalacia: a case report

    Directory of Open Access Journals (Sweden)

    Di Biagio Antonio

    2009-07-01

    Full Text Available Abstract Introduction Tenofovir disoproxil fumarate (Viread® is the only nucleotide reverse transcriptase inhibitor currently approved for the treatment of HIV. It is frequently prescribed not only for its efficacy but also for its decreased side effect profile compared with other nucleotide analogs. In addition, it is now increasingly recognized as a cause of acquired Fanconi's syndrome in individuals with HIV. Case presentation We describe a 48-year-old woman infected with HIV, with chronic renal insufficiency, who developed Fanconi's syndrome after inclusion of tenofovir disoproxil fumarate in her antiretroviral therapy. A whole body bone scintigraphy was performed, revealing an abnormal distribution of radiotracer uptake, with characteristic changes compatible with osteomalacia. All symptoms disappeared after tenofovir discontinuation and mineral supplementation. No other explanation for the sudden and complete resolution of the bone disease was found. Conclusion The case highlights the role of whole body bone scintigraphy in the diagnosis of tenofovir-related osteomalacia.

  12. Development of an Ergonomics Checklist for Investigation of Work-Related Whole-Body Disorders in Farming - AWBA: Agricultural Whole-Body Assessment.

    Science.gov (United States)

    Kong, Y K; Lee, S J; Lee, K S; Kim, G R; Kim, D M

    2015-10-01

    Researchers have been using various ergonomic tools to study occupational musculoskeletal diseases in industrial contexts. However, in agricultural work, where the work environment is poorer and the socio-psychological stress is high due to the high labor intensities of the industry, current research efforts have been scarce, and the number of available tools is small. In our preliminary studies, which focused on a limited number of body parts and other working elements, we developed separate evaluation tools for the upper and lower extremities. The current study was conducted to develop a whole-body ergonomic assessment tool for agricultural work that integrates the existing assessment tools for lower and upper extremities developed in the preliminary studies and to verify the relevance of the integrated assessment tool. To verify the relevance of the Agricultural Whole-Body Assessment (AWBA) tool, we selected 50 different postures that occur frequently in agricultural work. Our results showed that the AWBA-determined risk levels were similar to the subjective risk levels determined by experts. In addition, as the risk level increased, the average risk level increased to a similar extent. Moreover, the differences in risk levels between the AWBA and expert assessments were mostly smaller than the differences in risk levels between other assessment tools and the expert assessments in this study. In conclusion, the AWBA tool developed in this study was demonstrated to be appropriate for use as a tool for assessing various postures commonly assumed in agricultural work. Moreover, we believe that our verification of the assessment tools will contribute to the enhancement of the quality of activities designed to prevent and control work-related musculoskeletal diseases in other industries.

  13. From whole-body counting to imaging: The computer aided collimation gamma camera project (CACAO)

    Energy Technology Data Exchange (ETDEWEB)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Ballongue, P

    2000-07-01

    Whole-body counting is the method of choice for in vivo detection of contamination. To extend this well established method, the possible advantages of imaging radiocontaminants are examined. The use of the CACAO project is then studied. A comparison of simulated reconstructed images obtained by the CACAO project and by a conventional gamma camera used in nuclear medicine follows. Imaging a radionuclide contaminant with a geometrical sensitivity of 10{sup -2} seems possible in the near future. (author)

  14. From whole-body counting to imaging: The computer aided collimation gamma camera project (CACAO)

    International Nuclear Information System (INIS)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Ballongue, P.

    2000-01-01

    Whole-body counting is the method of choice for in vivo detection of contamination. To extend this well established method, the possible advantages of imaging radiocontaminants are examined. The use of the CACAO project is then studied. A comparison of simulated reconstructed images obtained by the CACAO project and by a conventional gamma camera used in nuclear medicine follows. Imaging a radionuclide contaminant with a geometrical sensitivity of 10 -2 seems possible in the near future. (author)

  15. Stability of Phase Relationships While Coordinating Arm Reaches with Whole Body Motion.

    Directory of Open Access Journals (Sweden)

    Romy S Bakker

    Full Text Available The human movement repertoire is characterized by the smooth coordination of several body parts, including arm movements and whole body motion. The neural control of this coordination is quite complex because the various body parts have their own kinematic and dynamic properties. Behavioral inferences about the neural solution to the coordination problem could be obtained by examining the emerging phase relationship and its stability. Here, we studied the phase relationships that characterize the coordination of arm-reaching movements with passively-induced whole-body motion. Participants were laterally translated using a vestibular chair that oscillated at a fixed frequency of 0.83 Hz. They were instructed to reach between two targets that were aligned either parallel or orthogonal to the whole body motion. During the first cycles of body motion, a metronome entrained either an in-phase or an anti-phase relationship between hand and body motion, which was released at later cycles to test phase stability. Results suggest that inertial forces play an important role when coordinating reaches with cyclic whole-body motion. For parallel reaches, we found a stable in-phase and an unstable anti-phase relationship. When the latter was imposed, it readily transitioned or drifted back toward an in-phase relationship at cycles without metronomic entrainment. For orthogonal reaches, we did not find a clear difference in stability between in-phase and anti-phase relationships. Computer simulations further show that cost models that minimize energy expenditure (i.e. net torques or endpoint variance of the reach cannot fully explain the observed coordination patterns. We discuss how predictive control and impedance control processes could be considered important mechanisms underlying the rhythmic coordination of arm reaches and body motion.

  16. Effects of whole-body gamma irradiation on oxygen transport by rat erythrocytes

    International Nuclear Information System (INIS)

    Thiriot, Christian; Kergonou, J.F.; Rocquet, Guy; Allary, Michel; Saint-Blancard, Jacques

    1982-01-01

    In this work, we studied the influence of whole-body gamma irradiation (8 Gy) upon oxygen transport by erythrocytes, through the erythrocyte count and related parameters, and through the factors affecting the oxygen affinity of hemoglobin. The oxygen affinity of hemoglobin is increased from day D + 5 after irradiation, and a severe erythropenia develops from day D + 8. These modifications probably result in tissue hypoxia via diminished oxygen transport from lungs to tissues, and decreased oxygen release from oxyhemoglobin in tissues

  17. Command Recognition of Robot with Low Dimension Whole-Body Haptic Sensor

    Science.gov (United States)

    Ito, Tatsuya; Tsuji, Toshiaki

    The authors have developed “haptic armor”, a whole-body haptic sensor that has an ability to estimate contact position. Although it is developed for safety assurance of robots in human environment, it can also be used as an interface. This paper proposes a command recognition method based on finger trace information. This paper also discusses some technical issues for improving recognition accuracy of this system.

  18. Beneficial effects of the whole-body cryotherapy on sport haemolysis

    OpenAIRE

    Banfi, Giuseppe; Melegati, Gianluca; Barassi, Alessandra; Melzi d'Eril, Gianvico

    2009-01-01

    Background. Sport's anemia is a common risk for athletes. The principal source of an accelerated turnover of the erythrocytes in sportsmen is the intravascular hemolysis. This phenomenon is induced by mechanical breakage for impact of feet and muscular contractions, but also by osmotic changes causing membrane fragility, typically evident after exercise, when free radicals are increased. Whole-body cryotherapy (WBC) covers a wide range of therapeutic applications and consists of briefly expos...

  19. Patient-Specific Biomechanical Model as Whole-Body CT Image Registration Tool

    OpenAIRE

    Li, Mao; Miller, Karol; Joldes, Grand Roman; Doyle, Barry; Garlapati, Revanth Reddy; Kikinis, Ron; Wittek, Adam

    2015-01-01

    Whole-body computed tomography (CT) image registration is important for cancer diagnosis, therapy planning and treatment. Such registration requires accounting for large differences between source and target images caused by deformations of soft organs/tissues and articulated motion of skeletal structures. The registration algorithms relying solely on image processing methods exhibit deficiencies in accounting for such deformations and motion. We propose to predict the deformations and moveme...

  20. Evaluation of radio-protective effect of melatonin on whole body irradiation induced liver tissue damage.

    Science.gov (United States)

    Shirazi, Alireza; Mihandoost, Ehsan; Ghobadi, Ghazale; Mohseni, Mehran; Ghazi-Khansari, Mahmoud

    2013-01-01

    Ionizing radiation interacts with biological systems to induce excessive fluxes of free radicals that attack various cellular components. Melatonin has been shown to be a direct free radical scavenger and indirect antioxidant via its stimulatory actions on the antioxidant system.The aim of this study was to evaluate the antioxidant role of melatonin against radiation-induced oxidative injury to the rat liver after whole body irradiation. In this experimental study,thirty-two rats were divided into four groups. Group 1 was the control group, group 2 only received melatonin (30 mg/kg on the first day and 30 mg/kg on the following days), group 3 only received whole body gamma irradiation of 10 Gy, and group 4 received 30 mg/kg melatonin 30 minutes prior to radiation plus whole body irradiation of 10 Gy plus 30 mg/kg melatonin daily through intraperitoneal (IP) injection for three days after irradiation. Three days after irradiation, all rats were sacrificed and their livers were excised to measure the biochemical parameters malondialdehyde (MDA) and glutathione (GSH). Each data point represents mean ± standard error on the mean (SEM) of at least eight animals per group. A one-way analysis of variance (ANOVA) was performed to compare different groups, followed by Tukey's multiple comparison tests (p<0.05). The results demonstrated that whole body irradiation induced liver tissue damage by increasing MDA levels and decreasing GSH levels. Hepatic MDA levels in irradiated rats that were treated with melatonin (30 mg/kg) were significantly decreased, while GSH levels were significantly increased, when compared to either of the control groups or the melatonin only group. The data suggest that administration of melatonin before and after irradiation may reduce liver damage caused by gamma irradiation.

  1. Whole body measurements of subjects who have ingested radioactive materials from the accident at Chernobyl

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1987-01-01

    Iodine-131 in the thyroid was the most significant nuclide that was detected in subjects monitored by the Australian Radiation Laboratory who might have been exposed by the Chernobyl nuclear accident. The estimated intake of I-131 by subjects ranged from 0.4 to 12 kBq, with a weighted committed dose equivalent (thyroid) of between 0.006 and 0.17 mSv. Whole-body monitoring data is presented for all subjects

  2. Subjective evaluation of the effectiveness of whole-body cryotherapy in patients with osteoarthritis

    Directory of Open Access Journals (Sweden)

    Tomasz Chruściak

    2016-12-01

    Full Text Available Objectives: One of the treatments for osteoarthritis (OA is whole-body cryotherapy (WBC. The aim of this study is to assess the effect of whole-body cryotherapy on the clinical status of patients with osteoarthritis (OA, according to their subjective feelings before and after the application of a 10-day cold treatment cycle. The aim is also to assess the reduction of intensity and frequency of pain, the reduction of the painkiller medication used, and to assess the possible impact on physical activity. Material and methods : The study involved 50 people, including 30 women (60% and 20 men (40%. Thirty-one patients had spondyloarthritis (62% of respondents, 10 had knee osteoarthritis (20%, and 9 hip osteoarthritis (18%. The overall average age was 50.1 ±10.9 years; the youngest patient was 29 years old and the oldest 73 years old. The average age of the women was 6 years higher. The study used a questionnaire completed by patients, and consisted of three basic parts. The modified Laitinen pain questionnaire contained questions concerning the intensity and frequency of pain, frequency of painkiller use and the degree of limited mobility. The visual analogue scale (VAS was used in order to subjectively evaluate the therapy after applying the ten-day treatment cycle. Results: According to the subjective assessment of respondents, after the whole-body cryotherapy treatments, a significant improvement occurred in 39 patients (78%, an improvement in 9 patients (18%, and no improvement was only declared by 2 patients (4%. Conclusions : Whole-body cryotherapy resulted in a reduction in the frequency and degree of pain perception in patients with osteoarthritis. WBC reduced the number of analgesic medications in these patients. It improved the range of physical activity and had a positive effect on the well-being of patients.

  3. Mechanisms of taurine hyperexcretion after whole-body irradiation of rats

    International Nuclear Information System (INIS)

    Beskrovnaya, L.A.; Lapteva, T.A.; Dokshina, G.A.; Baranova, M.I.

    1976-01-01

    Mechanisms of postirradiation hyperexcretion of taurine with urine have been investigated. In the course of three days after a whole-body exposure of rats (700 rads), the excretion of taurine increases. The experiments in vitro have demonstrated that taurine synthesis decreases in the thymus and liver of irradiated animals. The experiments conducted have shown that the postirradiation hyperexcretion of taurine is partly due to its release from the lymohoid tissue (thymus)

  4. Effects of whole-body cryotherapy on recovery after hamstring damaging exercise

    OpenAIRE

    Fonda, Borut; Šarabon, Nejc

    2013-01-01

    The purpose of this study was to examine the effects of whole-body cryotherapy (WBC) on biochemical, pain, and performance parameters during the 5-day recovery period after damaging exercise for hamstrings. Participants completed a bout of damaging exercise for the hamstring muscles on two separate occasions (control and experimental condition) separated by 10 weeks. During the control condition, subjects received no treatment after the damaging exercise. The experimental condition consisted ...

  5. Whole-Body Vibrations Associated With Alpine Skiing: A Risk Factor for Low Back Pain?

    Directory of Open Access Journals (Sweden)

    Matej Supej

    2018-03-01

    Full Text Available Alpine skiing, both recreational and competitive, is associated with high rates of injury. Numerous studies have shown that occupational exposure to whole-body vibrations is strongly related to lower back pain and some suggest that, in particular, vibrations of lower frequencies could lead to overuse injuries of the back in connection with alpine ski racing. However, it is not yet known which forms of skiing involve stronger vibrations and whether these exceed safety thresholds set by existing standards and directives. Therefore, this study was designed to examine whole-body vibrations connected with different types of skiing and the associated potential risk of developing low back pain. Eight highly skilled ski instructors, all former competitive ski racers and equipped with five accelerometers and a Global Satellite Navigation System to measure vibrations and speed, respectively, performed six different forms of skiing: straight running, plowing, snow-plow swinging, basic swinging, short swinging, and carved turns. To estimate exposure to periodic, random and transient vibrations the power spectrum density (PSD and standard ISO 2631-1:1997 parameters [i.e., the weighted root-mean-square acceleration (RMS, crest factor, maximum transient vibration value and the fourth-power vibration dose value (VDV] were calculated. Ground reaction forces were estimated from data provided by accelerometers attached to the pelvis. The major novel findings were that all of the forms of skiing tested produced whole-body vibrations, with highest PSD values of 1.5–8 Hz. Intensified PSD between 8.5 and 35 Hz was observed only when skidding was involved. The RMS values for 10 min of short swinging or carved turns, as well as all 10-min equivalent VDV values exceeded the limits set by European Directive 2002/44/EC for health and safety. Thus, whole-body vibrations, particularly in connection with high ground reaction forces, contribute to a high risk for low back

  6. Whole Body Vibration Training is Osteogenic at the Spine in College-Age Men and Women

    OpenAIRE

    Ligouri, Gianna C.; Shoepe, Todd C.; Almstedt, Hawley C.

    2012-01-01

    Osteoporosis is a chronic skeletal disease characterized by low bone mass which is currently challenging the American health care system. Maximizing peak bone mass early in life is a cost-effective method for preventing osteoporosis. Whole body vibration (WBV) is a novel exercise method with the potential to increase bone mass, therefore optimizing peak bone and decreasing the risk for osteoporotic fracture. The aim of this investigation was to evaluate changes in bone mineral density at the ...

  7. A critical evalution of 24 hours whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Bessent, R.G.; Scullion, J.E.; Cuthbert, G.F.

    1982-01-01

    In previous studies we have found that 24 hour whole-body retention (WBR) of diphosphonate is a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r = 0.998, p < 0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. The net whole-body count of a phantom representing the 24 hour whole-body distribution of tracer was 98% of that of a uniform phantom. Ten subjects, counted twice within a few minutes to study the effect of repositioning showed a mean difference between counts of only 0.8%. For eleven subjects with traumatic fractures it was found that 9 had normal values for WBR, while 2 had minimally elevated results. For twenty patients with renal disease but no apparent skeletal disease a significant correlation between serum creatinine and WBR was found (r = 0.72, p<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/l. It is suggested that WBR measurement is accurate and the technique is highly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is in the normal range then an elevated WBR result can be assumed to reflect increased skeletal metabolism without further concern as to renal function. (Author)

  8. Vibration energy absorption in the whole-body system of a tractor operator

    OpenAIRE

    Jan Szczepaniak; Wojciech Tanaś; Jacek Kromulski

    2014-01-01

    Many people are exposed to whole-body vibration (WBV) in their occupational lives, especially drivers of vehicles such as tractor and trucks. The main categories of effects from WBV are perception degraded comfort interference with activities-impaired health and occurrence of motion sickness. Absorbed power is defined as the power dissipated in a mechanical system as a result of an applied force. The vibration-induced injuries or disorders in a substructure of the human system are primari...

  9. Autoradiographic changes in the kidney of the whole-body sublethally x-ray irradiated rat

    Energy Technology Data Exchange (ETDEWEB)

    Olinic, A; Uray, Z

    1977-01-01

    203Hg-hydroxymersalyl uptake/gram of kidney (HU), renal autoradiographic and histologic aspect after 800 R x-ray whole-body rat irradiation was studied. Twenty-four to seventy-two hours after irradiation, HU increased, while tubular autoradiographic granularity decreased. Their return to the control levels occurred gradually within two weeks. The relations of these findings to the early circulatory and dystrophic changes, as well as to the subsequent postirradiation restoring renal process are discussed.

  10. Adaptive statistical iterative reconstruction technology in the application of PET/CT whole body scans

    International Nuclear Information System (INIS)

    Xin Jun; Zhao Zhoushe; Li Hong; Lu Zhe; Wu Wenkai; Guo Qiyong

    2013-01-01

    Objective: To improve image quality of low dose CT in whole body PET/CT using adaptive statistical iterative reconstruction (ASiR) technology. Methods: Twice CT scans were performed with GE water model,scan parameters were: 120 kV, 120 and 300 mA respectively. In addition, 30 subjects treated with PET/CT were selected randomly, whole body PET/CT were performed after 18 F-FDG injection of 3.70 MBq/kg, Sharp IR+time of flight + VUE Point HD technology were used for 1.5 min/bed in PET; CT of spiral scan was performed under 120 kV using automatic exposure control technology (30-210 mA, noise index 25). Model and patients whole body CT images were reconstructed with conventional and 40% ASiR methods respectively, and the CT attenuation value and noise index were measured. Results: Research of model and clinical showed that standard deviation of ASiR method in model CT was 33.0% lower than the conventional CT reconstruction method (t =27.76, P<0.01), standard deviation of CT in normal tissues (brain, lung, mediastinum, liver and vertebral body) and lesions (brain, lung, mediastinum, liver and vertebral body) reduced by 21.08% (t =23.35, P<0.01) and 24.43% (t =16.15, P<0.01) respectively, especially for normal liver tissue and liver lesions, standard deviations of CT were reduced by 51.33% (t=34.21, P<0.0) and 49.54% (t=15.21, P<0.01) respectively. Conclusion: ASiR reconstruction method was significantly reduced the noise of low dose CT image and improved the quality of CT image in whole body PET/CT, which seems more suitable for quantitative analysis and clinical applications. (authors)

  11. A shielding chamber for the Rossendorf whole-body counter; Eine Abschirmkammer fuer den Rossendorfer Ganzkoerperzaehler

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, Stephan; Loehnert, Daniela [VKTA - Strahlenschutz, Analytik und Entsorgung Rossendorf e.V., Dresden (Germany).; Schreiber, Wolfgang [Ingenieurbedarf G. Schoene und W. Schreiber GmbH, Radeberg (Germany)

    2017-08-01

    A large part of radionuclides to be evaluated in the frame of incorporation monitoring are gamma emitter that can be directly measured (in vivo). In order to reach the required detection limits for the relevant radionuclides in the short measuring time high effort is necessary for the shielding of natural radioactivity. The contribution describes planning, construction and installation of the shielding chamber for the new in vivo whole body counter in Rossendorf. First experiences and preliminary results are discussed.

  12. Cutaneous noradrenaline measured by microdialysis in complex regional pain syndrome during whole-body cooling and heating

    DEFF Research Database (Denmark)

    Terkelsen, Astrid Juhl; Gierthmühlen, Janne; Petersen, Lars J.

    2013-01-01

    and in healthy volunteers. Seven patients and nine controls completed whole-body cooling (sympathetic activation) and heating (sympathetic inhibition) induced by a whole-body thermal suit with simultaneous measurement of the skin temperature, skin blood flow, and release of dermal noradrenaline. CRPS pain...

  13. Changes in serum 25-hydroxyvitamin D and cholecalciferol after one whole-body exposure in a commercial tanning bed

    DEFF Research Database (Denmark)

    Langdahl, Jacob H; Schierbeck, Louise Lind; Bang, Ulrich Christian

    2012-01-01

    We wanted to evaluate the cutaneous synthesis of 25OHD and cholecalciferol after one whole-body exposure to ultraviolet radiation type B (UVB) in a randomized setup. Healthy volunteers were randomized to one whole-body exposure in a commercial tanning bed with UVB emission (UVB/UVA ratio 1...

  14. Clinical evaluation of exercise thallium-201 whole body scintigraphy in ischemic heart disease

    International Nuclear Information System (INIS)

    Kaneko, Kenzo; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    To evaluate whole body distribution and kinetics of Thallium-201 at exercise and redistribution, whole body scintigraphy (WB-S) was performed on 12 normal subjects (N), 19 patients with angina pectoris (AP) and 18 patients with old myocardial infarction (MI). WB-S was obtained using a gamma camera OMEGA 500 and analized by ADAC System IV. We estimated the following parameters from WB-S; 1) %Distribution (%D): the ratio of whole body counts to organ counts 2) washout rate (WR) in each organ. %D of the heart in N, AP and MI was similar at rest and exercise. At exercise, %D of the lung and the liver decreased and %D of thighs increased remarkably than at rest. At supine exercise, the lung indicated high %D and thinghs indicated low %D compared with at upright exercise. WR of the heart in AP and MI was significantly lower than in N (p<0.005, p<0.01) and further decreased proportionally to the number of stenotic coronary arteries and related to the ischemic ST depression of exercise ECG. WR of the heart was not correlation with pressure rate product and this finding suggested that WR of the heart was not prescribed by the tolerance of exercise but related to coronary flow at exercise a certain degree. WR of the lung in MI was significantly higher (p<0.025) and WR of thighs in AP and MI was significantly lower (p<0.025, p<0.05) compared with N. (author)

  15. Effect of alcohol consumption on whole-body protein turnover in healthy adults.

    Science.gov (United States)

    Wutzke, Klaus D; Krentz, Helga; Bruns, Gerrit

    2011-03-01

    The aim of the study was to investigate the whole-body protein turnover, either before or after continuous, moderate ethanol-induced oxidative stress by red wine consumption over a relatively short period in healthy volunteers. Ten healthy adults received an individual regular diet over 20 days. After 10 days, the subjects consumed 0.4 ml ethanol kg(-1) day(-1) as red wine together with dinner over a 10-day period. After 8 and 18 days, respectively, a (15)N-labelled yeast protein was administered in a dosage of 4.2 mg kg(-1) body weight. Urine and faeces were collected over 48 h, respectively. The (15)N-enrichment was measured by isotope ratio mass spectrometry, whereas the protein flux rates were calculated by a three-compartment model. The whole-body protein turnover without/with red wine consumption amounted to 3.73±0.6 and 3.49±0.6 g kg(-1) day(-1) (not significant), respectively. Moderate alcohol consumption does not induce significant short-term changes in the whole-body protein turnover of healthy adults.

  16. Effective dose estimation in whole-body multislice CT in paediatric trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Robin D.; Saueressig, Ulrich; Kotter, Elmar; Langer, Mathias; Bley, Thorsten A. [University Hospital, Department of Radiology, Freiburg im Breisgau (Germany); Strohm, Peter C.; Zwingmann, Joern; Suedkamp, Norbert P. [University Hospital, Department of Orthopaedic and Trauma Surgery, Freiburg im Breisgau (Germany); Uhl, Markus [University Hospital, Department of Radiology, Section of Paediatric Radiology, Freiburg im Breisgau (Germany)

    2009-03-15

    The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the clinicians with relevant information to initiate life-saving therapy. Radiologists should use special paediatric protocols that include dose-saving mechanisms to keep the effective dose as low as possible. Further studies are needed to examine and advance dose-saving strategies in MSCT, especially in children. (orig.)

  17. Whole body organization during a symmetric bimanual pick up task in overweight and obese children.

    Science.gov (United States)

    Hung, Ya-Ching; Mangiafreno, Melissa; Gill, Simone V

    2017-02-01

    Information on the effects of obesity on the biomechanics of whole body movement control in children is limited. The purpose of the current study is to test the hypothesis that during a simple pick up task, overweight and obese children will organize their whole body movements differently than those in normal weight children. Twelve children who were overweight or obese (5-13 years old) and twelve age matched normal weight children participated in the study. Children picked up an empty box to waist height at a self-selected pace while kinematic and kinetic data were recorded and analyzed using a VICON system and two AMTI force plates. The overweight and obese group showed less knee flexion in both legs, more spine flexion, and less excursion in the height of their center of mass (all Psoverweight and obese group had more anterior movement in their center of mass (Poverweight and obese group had greater anterior excursion with faster average anterior moving speed and spent a longer time with the center of pressure reached forward (all Psoverweight and obese children organize their whole body movement during a simple pick up task differently with higher and more forward center of mass, quickly shifting their center of pressure anteriorly, and with a longer period of time with the center of pressure remaining forward. Their movement strategy may put them in a less stable condition and thus make them prone to losing balance. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    Energy Technology Data Exchange (ETDEWEB)

    Risco Norrlid, L. del (Swedish Radiation Safety Authority (Sweden)); Halldorsson, O. (Icelandic Radiation Safety Authority (Iceland)); Holm, S. (NM and PET at Copenhagen' s Univ. Hospital (Denmark)); Huikari, J. (Radiation and Nuclear Safety Authority (Finland)); Isaksson, M. (Goeteborg Univ., Dept. Radiation Physics Sahlgren Academy (Sweden)); Lind, B. (Norwegian Radiation Protection Authority (Norway)); Roed, H. (Danish State Institute for Radiation Protection (Denmark))

    2011-02-15

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  19. Caffeine protects mice against whole-body lethal dose of {gamma}-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    George, K.C.; Hebbar, S.A.; Kale, S.P.; Kesavan, P.C. [Biosciences Group, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    1999-06-01

    Administration of caffeine (1,3,7-trimethylxanthine), a major component of coffee, to Swiss mice at doses of 80 or 100 mg/kg body weight 60 min prior to whole-body lethal dose of {gamma}-irradiation (7.5 Gy) resulted in the survival of 70 and 63% of animals, respectively, at the above doses in contrast to absolutely no survivors (LD-100/25 days) in the group exposed to radiation alone. Pre-treatment with a lower concentration of caffeine (50 mg/kg) did not confer any radioprotection. The protection exerted by caffeine (80 mg/kg), however, was reduced from 70 to 50% if administered 30 min prior to irradiation. The trend statistics reveal that a dose of 80 mg/kg administered 60 min before whole-body exposure to 7.5 Gy is optimal for maximal radioprotection. However, caffeine (80 mg/kg) administered within 3 min after irradiation offered no protection. While there is documentation in the literature that caffeine is an antioxidant and radioprotector against the toxic pathway of radiation damage in a wide range of cells and organisms, this is the first report demonstrating unequivocally its potent radioprotective action in terms of survival of lethally whole-body irradiated mice. (author)

  20. In-vivo assessment of whole-body radioisotope burdens at the Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Vasilik, D.G.; Aikin, I.C.

    1983-08-01

    The Los Alamos National Laboratory program for in-vivo measurements includes the capability for the whole-body assessment of body burdens for x-ray or gamma-ray emitting radioisotopes. This capability is an important part of the health and safety program at Los Alamos where a wide variety of radioisotopes are utilized. This report addresses the whole body portion of our in-vivo measurement capabilities. Whole-body measurements at Los Alamos make use of a hyperpure germanium (HpGe) detector and a lithium-drifted germanium [Ge(Li)] detector for identification and quantification of radioisotopes. Analysis results are interpreted in terms of two basic statistical measures of detection limits. One measure is called the minimum significant measured activity (MSMA), which is interpreted as meaning that there is some activity in the body. The second measure is called the minimum detectable true activity (MDTA), which is defined as the smallest amount of activity required to be in the body in order that a measurement of an individual can be expected to imply correctly the presence of activity with a predetermined degree of confidence. 7 references, 8 figures

  1. Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-l-tyrosine

    International Nuclear Information System (INIS)

    Pauleit, Dirk; Floeth, Frank; Herzog, Hans; Tellmann, Lutz; Langen, Karl-J.; Hamacher, Kurt; Coenen, Heinz H.; Mueller, Hans-W.

    2003-01-01

    The whole-body distribution of O-(2-[ 18 F]fluoroethyl)-l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV ≤1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 μSv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET. (orig.)

  2. Whole-body distribution and dosimetry of O-(2-[{sup 18}F]fluoroethyl)-l-tyrosine

    Energy Technology Data Exchange (ETDEWEB)

    Pauleit, Dirk [Clinic of Nuclear Medicine, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany); Clinic of Nuclear Medicine, Research Center Juelich, P.O. Box 1913, 52425, Juelich (Germany); Floeth, Frank [Department of Neurosurgery, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany); Herzog, Hans; Tellmann, Lutz; Langen, Karl-J. [Institute of Medicine, Research Center Juelich, Juelich (Germany); Hamacher, Kurt; Coenen, Heinz H. [Institute of Nuclear Chemistry, Research Center Juelich, Juelich (Germany); Mueller, Hans-W. [Clinic of Nuclear Medicine, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany)

    2003-04-01

    The whole-body distribution of O-(2-[{sup 18}F]fluoroethyl)-l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV {<=}1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 {mu}Sv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET. (orig.)

  3. Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-L-tyrosine.

    Science.gov (United States)

    Pauleit, Dirk; Floeth, Frank; Herzog, Hans; Hamacher, Kurt; Tellmann, Lutz; Müller, Hans-W; Coenen, Heinz H; Langen, Karl-J

    2003-04-01

    The whole-body distribution of O-(2-[(18)F]fluoroethyl)- l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV

  4. Local forearm and whole-body respiratory quotient in humans after an oral glucose load

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Madsen, J

    1993-01-01

    the glucose load and had not returned to baseline level at the end of the experiment. Whole-body respiratory quotient (RQ) was, on average, 0.80 (SD 0.05) in the baseline condition and increased to a maximum of 0.91 (0.03) and then decreased to baseline level at the end of the experiment. The local forearm.......17) to 0.63 (0.17) 30 min after the glucose load (P glucose load RQ increased to a maximum level at 0.95 (0.22) and decreased then gradually to baseline level. The experiments emphasize several methodological problems in the measurement of local forearm RQ. The whole-body RQ......The effects of an oral glucose load of 75 g on the local forearm and whole-body energy thermogenesis were measured in normal subjects during the 4 h after the glucose intake. Simultaneous assessment of substrate metabolism in the forearm was performed. Energy expenditure (EE) increased after...

  5. Whole-body muscle MRI in 20 patients suffering from late onset Pompe disease: Involvement patterns.

    Science.gov (United States)

    Carlier, Robert-Yves; Laforet, Pascal; Wary, Claire; Mompoint, Dominique; Laloui, Kenza; Pellegrini, Nadine; Annane, Djillali; Carlier, Pierre G; Orlikowski, David

    2011-11-01

    To describe muscle involvement on whole-body MRI scans in adult patients at different stages of late-onset Pompe disease. Twenty patients aged 37 to 75 were examined. Five were bedridden and required ventilatory support. Axial and coronal T1 turbo-spin-echo sequences were performed on 1.5T or 3T systems. MRI was scored for 47 muscles using Mercuri's classification. Whole-body scans were obtained with a mean in-room time of 29 min. Muscle changes consisted of internal bright signals of fatty replacement without severe retraction of the muscles' corpus. Findings were consistent with previous descriptions of spine extensors and pelvic girdle, but also provided new information on recurrent muscle changes particularly in the tongue and subscapularis muscle. Moreover thigh involvement was more heterogeneous than previously described, in terms of distribution across muscles as well as with respect to the overall clinical presentation. Whole-body MRI provides a very evocative description of muscle involvement in Pompe disease in adults. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Effects of whole-body irradiation on neonatally thymectomized mice. Incidence of benign and malignant tumors

    International Nuclear Information System (INIS)

    Anderson, R.E.; Howarth, J.L.; Troup, G.M.

    1978-01-01

    The individual and combined effects of neonatal thymectomy and whole-body irradiation on the prevalence of benign and malignant tumors in germ-free female mice of the Charles Rivers line were studied to determine if a portion of the tumorigenic effects of irradiation can be attributed to injury of the thymic-dependent component of the immune response. Neonatal thymectomy increased (a) the incidence of benign and malignant tumors and (b) the prevalence of multiple primary neoplasms in an individual mouse. Whole-body exposure to 700 rad at 6 weeks of age further increased the incidence of tumors, but the relative magnitude of this increase was less pronounced than in sham-operated controls. Thus, the cumulative effects of thymectomy plus irradiation are less pronounced than the sum of the individual effects. One of several possible explanations for this observation is that a portion of the carcinogenic effects of whole-body irradiation is mediated by suppression of the thymic-dependent component of the immune response

  7. [Muscular disorders associated with ankylosing spondylitis and their correction with the help of whole body cryotherapy].

    Science.gov (United States)

    Kulikov, A G; Tabiev, V I; Rassulova, M A

    2015-01-01

    The objective of the present study was to evaluate the possibilities for the correction of muscular disorders associated with ankylosing spondylitis and their correction with the help of whole body cryotherapy. The study included 55 patients randomly allocated to two groups. Group 1 was comprised of the patients treated with the use of the common mineral baths, physiotherapy, therapeutic physical exercises, spinal massage, and whole body air-cryotherapy. Group 2 contained the patients who were treated in a similar way with the exception of whole body cryotherapy; they served as controls. Muscular disorders were diagnosed by means of functional muscular testing. The study has demonstrated the high prevalence of muscular disorders in the patients suffering from ankylosing spondylitis. Moreover, it revealed the profile of such disorders associated with ankylosing spondylitis and showed significant correlation between the results of functional muscular testing, BASMI and BASFI indices as well as characteristics of chest excursions (pcryotherapy in comparison with the alternative therapeutic modalities employed in the present study. This therapeutic modality ensured the statistically more pronounced improvement of functional muscular testing parameters (pcryotherapy accounting for its corrective influence on the muscular disorders in the patients presenting with ankylosing spondylitis. It is concluded that the proposed approach can be recommended for the introduction in the combined therapeutic and rehabilitative treatment of muscular disorders associated with ankylosing spondylitis.

  8. An experimental test on large animals of MCNP application for whole body counting

    International Nuclear Information System (INIS)

    Borisov, N.; Yatsenko, V.; Kochetkov, O.; Gusev, I.; Vlasov, P.; Kalistratova, V.; Nisimov, P.; Levochkin, F.; Borovkov, M.; Stolyarov, V.; Tsedish, S.; Tyurin, I.; Franck, D.; Carlan, L. de

    2005-01-01

    Measurements of actinide body burden using whole body counting spectrometry is hampered due to intensive absorption of γ-rays inside the patient's body, which depends on the anatomy of a patient. To establish the correspondence between pulse-height-spectra intensity and radionuclide activity, Monte Carlo calculations are widely used. For such calculations, the radiation transport geometry is usually described in terms of small rectangular boxes (voxels) retrieved from computed tomography or magnetic resonance images. The software for Monte Carlo-assisted calibration of whole body counting, which performs automatic creation of individual MCNP voxel phantoms, was checked in a quasi-in vivo experiment on large animals. During the experiment, pigs of 35-40 kg body mass were used as phantoms for measurement of actinides body burden. 241 Am was administered (via injection of a radioactive solution or via implantation of plastic capsules containing the radioactive material) into the lungs of pigs. The pigs were measured using the pure germanium low-energy γ-spectrometers. The images of animals were obtained using the computed tomography machine. On the base of these tomograms, MCNP4c2 calculations were done to obtain the pulse-height-spectra of the whole body counters. The experimental results were reproduced in calculations with error of less than 30% for 241 Am administered via injection and less than 10% for 241 Am administered inside the capsules. (authors)

  9. Estimation of whole body dose in an unusual event: spillage of radioactive material on the chair

    International Nuclear Information System (INIS)

    Adtani, M.M.; Biju, K.; Deshpande, M.D.; Shivde, R.K.; Kulkarni, V.V.

    2005-01-01

    The personnel monitoring in India is done using thermoluminescence dosimeters worn at chest level. In research institutions and in nuclear facilities where radiation sources are processed in dispersible forms, a remote possibility exists that radiation source entering in the area where installed monitor does not exist and the source may get spilled on chair and causing exposure to persons sitting on the chair. In such case TLD may not give the correct exposure as there is shielding of individuals body. An attempt is made to find out a factor for estimating the whole body dose by knowing the TLD badge dose or by measuring the gonad dose. Experiments are performed using TLDs and also measurement by teletector. Monte Carlo simulations are also done. It is observed that a factor of 8 to TLD Badge dose will give whole body dose if worker has received dose only on said chair or by applying a factor of 0.23 to dose measured at gonad level will give whole body dose. (author)

  10. Importance of Intercomparison Exercises in Assessment of Internal Exposure by Whole-Body Counter

    International Nuclear Information System (INIS)

    Andrasi, A.

    2001-01-01

    Full text: Basic requirement for any kind of measurement is to check and prove the reliability and correctness of the measured results. Quality assurance programmes require several activities among which the participation in intercomparison exercises plays an important role. Since the determination of radioactive materials in the human body by whole-body counting technique implies many sources of uncertainties the reliability of calibration data and consequently the measured results have to be checked by participation in intercomparison quality control programmes. In these programmes mostly different kinds of phantoms simulating the human body are circulated among the participating laboratories, however sometimes contaminated persons are also subjects of intercomparison measurements. There are guidelines in several countries laid down concerning the requirements of whole-body counter measurements where the performance criteria for the relative bias, precision and minimum detectable amounts are formulated. These quantities are mostly the subject of intercomparison programmes. The whole body counter laboratory of the KFKI Atomic Energy Research Institute participated in intercomparison exercises several times in the last few years. The lessons learned during these activities helped in checking the capabilities of applied methods and measuring geometry as well as contributed in improving the accuracy of the measured results. A short overview on the previous international intercomparison exercises their main characteristics the results obtained and conclusions drawn are discussed in the paper with special attention to those in which also our laboratory participated. (author)

  11. Optimized workflow and imaging protocols for whole-body oncologic PET/MRI.

    Science.gov (United States)

    Ishii, Shirou; Hara, Takamitsu; Nanbu, Takeyuki; Suenaga, Hiroki; Sugawara, Shigeyasu; Kuroiwa, Daichi; Sekino, Hirofumi; Miyajima, Masayuki; Kubo, Hitoshi; Oriuchi, Noboru; Ito, Hiroshi

    2016-11-01

    Although PET/MRI has the advantages of a simultaneous acquisition of PET and MRI, high soft-tissue contrast of the MRI images, and reduction of radiation exposure, its low profitability and long acquisition time are significant problems in clinical settings. Thus, MRI protocols that meet oncological purposes need to be used in order to reduce examination time while securing detectability. Currently, half-Fourier acquisition single-shot turbo spin echo and 3D-T1 volumetric interpolated breath-hold examination may be the most commonly used sequences for whole-body imaging due to their shorter acquisition time and higher diagnostic accuracy. Although there have been several reports that adding diffusion weighted image (DWI) to PET/MRI protocol has had no effect on tumor detection to date, in cases of liver, kidney, bladder, and prostate cancer, the use of DWI may be beneficial in detecting lesions. Another possible option is to scan each region with different MRI sequences instead of scanning the whole body using one sequence continuously. We herein report a workflow and imaging protocols for whole-body oncologic PET/MRI using an integrated system in the clinical routine, designed for the detection, for example by cancer screening, of metastatic lesions, in order to help future users optimize their workflow and imaging protocols.

  12. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L.

    2009-01-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  13. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    International Nuclear Information System (INIS)

    Risco Norrlid, L. del; Halldorsson, O.; Holm, S.; Huikari, J.; Isaksson, M.; Lind, B.; Roed, H.

    2011-02-01

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  14. Whole-body magnetic resonance imaging in children: state of the art

    Directory of Open Access Journals (Sweden)

    Sara Reis Teixeira

    2015-04-01

    Full Text Available Whole-body imaging in children was classically performed with radiography, positron-emission tomography, either combined or not with computed tomography, the latter with the disadvantage of exposure to ionizing radiation. Whole-body magnetic resonance imaging (MRI, in association with the recently developed metabolic and functional techniques such as diffusion-weighted imaging, has brought the advantage of a comprehensive evaluation of pediatric patients without the risks inherent to ionizing radiation usually present in other conventional imaging methods. It is a rapid and sensitive method, particularly in pediatrics, for detecting and monitoring multifocal lesions in the body as a whole. In pediatrics, it is utilized for both oncologic and non-oncologic indications such as screening and diagnosis of tumors in patients with genetic syndromes, evaluation of disease extent and staging, evaluation of therapeutic response and post-therapy follow-up, evaluation of non neoplastic diseases such as multifocal osteomyelitis, vascular malformations and syndromes affecting multiple regions of the body. The present review was aimed at describing the major indications of whole-body MRI in pediatrics added of technical considerations.

  15. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: cmo@cdtn.br

    2009-07-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  16. Wireless Cortical Brain-Machine Interface for Whole-Body Navigation in Primates

    Science.gov (United States)

    Rajangam, Sankaranarayani; Tseng, Po-He; Yin, Allen; Lehew, Gary; Schwarz, David; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.

    2016-03-01

    Several groups have developed brain-machine-interfaces (BMIs) that allow primates to use cortical activity to control artificial limbs. Yet, it remains unknown whether cortical ensembles could represent the kinematics of whole-body navigation and be used to operate a BMI that moves a wheelchair continuously in space. Here we show that rhesus monkeys can learn to navigate a robotic wheelchair, using their cortical activity as the main control signal. Two monkeys were chronically implanted with multichannel microelectrode arrays that allowed wireless recordings from ensembles of premotor and sensorimotor cortical neurons. Initially, while monkeys remained seated in the robotic wheelchair, passive navigation was employed to train a linear decoder to extract 2D wheelchair kinematics from cortical activity. Next, monkeys employed the wireless BMI to translate their cortical activity into the robotic wheelchair’s translational and rotational velocities. Over time, monkeys improved their ability to navigate the wheelchair toward the location of a grape reward. The navigation was enacted by populations of cortical neurons tuned to whole-body displacement. During practice with the apparatus, we also noticed the presence of a cortical representation of the distance to reward location. These results demonstrate that intracranial BMIs could restore whole-body mobility to severely paralyzed patients in the future.

  17. Estimation of the protein synthesis rates of the whole body of growing broilers

    International Nuclear Information System (INIS)

    Koehler, R.; Pahle, T.; Gruhn, K.; Zander, R.; Jeroch, H.; Gebhardt, G.

    1988-01-01

    The purpose of the investigations was to prove a method, developed for monogastric mammalians, based on a 3-compartment model and assuming a proportional growth of the pools of total N, whether it is applicable to growing poultry. The tracer, 15 N-L-lysine, was given quasi-continuously for four days. In this time and in the following period of five days without tracer intake, the 15 N excretion in the urine was measured. The average of the live weight of the broiler cockerels was 1724 g. The animals were colostomized for sampling the urine separately. Using the fluxes of lysine, the calculation of the whole-body protein synthesis rate was 64.1 g/d. The protein degradation rate was 54.4 g/d. The adequate values of the fractional rates of protein synthesis and degradation for the whole body (without feathers) were 23.3% and 19.8%, resp. Thus it is clearly shown, that the method applied gives real data of the parameters of the N metabolism for growing broilers, being in the range of values for muscle proteins and proteins of the whole body of growing poultry, published by other authors. (author)

  18. Radioprotection by caffeine pre-treatment and post-treatment in the bone marrow chromosomes of mice given whole-body [gamma]-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Farooqi, Z.; Kesavan, P.C. (Jawaharlal Nehru Univ., New Delhi (India). School of Life Sciences)

    1992-10-01

    The effect of caffeine given as pre- and post-treatment in mice exposed to whole-body [gamma]-irradiation (1.5 Gy [sup 60]Co [gamma]-rays) was studied. The pre-treatment was either acute or chronic. The acute dose (5 mg/kg and 15 mg/kg body weight) was in the form of an injection given intraperitoneally, 30 min before irradiation. The chronic administration was in the form of caffeine solution (4.208x10[sup -3] M and 7.72x10[sup -4] M) contained in drinking water for 5 weeks prior to radiation exposure. The acute pre-treatment with caffeine reduced the radiation-induced frequency of chromosomal aberrations discernibly, whereas chronic pre-treatment afforded a much more significant degree of radioprotection. The caffeine post-treatment (5 mg/kg and 15 mg/kg body weight) was given in the form of an intraperitoneal injection to the mice immediately following whole-body [gamma]-irradiation. It is noted that both post-treatment concentrations of caffeine also significantly reduced the frequency of chromosomal aberrations induced by [gamma]-rays. These data are briefly discussed in terms of possible mechanistic considerations. (author). 33 refs.; 3 tabs.

  19. Radioprotection by caffeine pre-treatment and post-treatment in the bone marrow chromosomes of mice given whole-body γ-irradiation

    International Nuclear Information System (INIS)

    Farooqi, Z.; Kesavan, P.C.

    1992-01-01

    The effect of caffeine given as pre- and post-treatment in mice exposed to whole-body γ-irradiation (1.5 Gy 60 Co γ-rays) was studied. The pre-treatment was either acute or chronic. The acute dose (5 mg/kg and 15 mg/kg body weight) was in the form of an injection given intraperitoneally, 30 min before irradiation. The chronic administration was in the form of caffeine solution (4.208x10 -3 M and 7.72x10 -4 M) contained in drinking water for 5 weeks prior to radiation exposure. The acute pre-treatment with caffeine reduced the radiation-induced frequency of chromosomal aberrations discernibly, whereas chronic pre-treatment afforded a much more significant degree of radioprotection. The caffeine post-treatment (5 mg/kg and 15 mg/kg body weight) was given in the form of an intraperitoneal injection to the mice immediately following whole-body γ-irradiation. It is noted that both post-treatment concentrations of caffeine also significantly reduced the frequency of chromosomal aberrations induced by γ-rays. These data are briefly discussed in terms of possible mechanistic considerations. (author). 33 refs.; 3 tabs

  20. Diffusion-weighted imaging and proton MR spectroscopy in the characterization of acute disseminated encephalomyelitis

    International Nuclear Information System (INIS)

    Balasubramanya, K.S.; Kovoor, J.M.E.; Jayakumar, P.N.; Ravishankar, S.; Kamble, R.B.; Panicker, J.; Nagaraja, D.

    2007-01-01

    Acute disseminated encephalomyelitis (ADEM) is usually a monophasic illness characterized by multiple lesions involving gray and white matter. Quantitative MR techniques were used to characterize and stage these lesions. Eight patients (seven males and one female; mean age 19 years, range 5 to 36 years) were studied using conventional MRI (T2- and T1-weighted and FLAIR sequences), diffusion-weighted imaging (DWI) and proton magnetic resonance spectroscopy (MRS). Apparent diffusion coefficient (ADC) values and MRS ratios were calculated for the lesion and for normal-appearing white matter (NAWM). Three patients were imaged in the acute stage (within 7 days of the onset of neurological symptoms) and five in the subacute stage (after 7 days from the onset of symptoms). ADC values in NAWM were in the range 0.7-1.24 x 10 -3 mm/s 2 (mean 0.937 ± 0.17 mm/s 2 ). ADC values of ADEM lesions in the acute stage were in the range 0.37-0.68 x 10 -3 mm/s 2 (mean 0.56 ± 0.16 mm/s 2 ) and 1.01-1.31 x 10 -3 mm/s 2 (mean 1.24 ± 0.13 mm/s 2 ) in the subacute stage. MRS ratios were obtained for all patients. NAA/Cho ratios were in the range 1.1-3.5 (mean 1.93 ± 0.86) in the NAWM. NAA/Cho ratios within ADEM lesions in the acute stage were in the range 0.63-1.48 (mean 1.18 ± 0.48) and 0.29-0.84 (mean 0.49 ± 0.22) in the subacute stage. The ADC values, NAA/Cho and Cho/Cr ratios were significantly different between lesions in the acute and subacute stages (P < 0.001, P < 0.027, P < 0.047, respectively). ADC values were significantly different between lesions in the acute (P < 0.009) and subacute stages (P < 0.005) with NAWM. In addition, NAA/Cho and Cho/Cr ratios were significantly different between lesions in the subacute stage and NAWM (P < 0.006, P < 0.007, respectively). ADEM lesions were characterized in the acute stage by restricted diffusion and in the subacute stage by free diffusion and a decrease in NAA/Cho ratios. Restricted diffusion and progressive decrease in NAA

  1. Diffusion-weighted imaging and proton MR spectroscopy in the characterization of acute disseminated encephalomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Balasubramanya, K.S.; Kovoor, J.M.E.; Jayakumar, P.N.; Ravishankar, S.; Kamble, R.B. [National Institute of Mental Health and Neurosciences, Department of Neuroimaging and Interventional Radiology, Bangalore, Karnataka (India); Panicker, J.; Nagaraja, D. [National Institute of Mental Health and Neurosciences, Department of Neurology, Bangalore (India)

    2007-02-15

    Acute disseminated encephalomyelitis (ADEM) is usually a monophasic illness characterized by multiple lesions involving gray and white matter. Quantitative MR techniques were used to characterize and stage these lesions. Eight patients (seven males and one female; mean age 19 years, range 5 to 36 years) were studied using conventional MRI (T2- and T1-weighted and FLAIR sequences), diffusion-weighted imaging (DWI) and proton magnetic resonance spectroscopy (MRS). Apparent diffusion coefficient (ADC) values and MRS ratios were calculated for the lesion and for normal-appearing white matter (NAWM). Three patients were imaged in the acute stage (within 7 days of the onset of neurological symptoms) and five in the subacute stage (after 7 days from the onset of symptoms). ADC values in NAWM were in the range 0.7-1.24 x 10{sup -3} mm/s{sup 2} (mean 0.937 {+-} 0.17 mm/s{sup 2}). ADC values of ADEM lesions in the acute stage were in the range 0.37-0.68 x 10{sup -3} mm/s{sup 2} (mean 0.56 {+-} 0.16 mm/s{sup 2}) and 1.01-1.31 x 10{sup -3} mm/s{sup 2} (mean 1.24 {+-} 0.13 mm/s{sup 2}) in the subacute stage. MRS ratios were obtained for all patients. NAA/Cho ratios were in the range 1.1-3.5 (mean 1.93 {+-} 0.86) in the NAWM. NAA/Cho ratios within ADEM lesions in the acute stage were in the range 0.63-1.48 (mean 1.18 {+-} 0.48) and 0.29-0.84 (mean 0.49 {+-} 0.22) in the subacute stage. The ADC values, NAA/Cho and Cho/Cr ratios were significantly different between lesions in the acute and subacute stages (P < 0.001, P < 0.027, P < 0.047, respectively). ADC values were significantly different between lesions in the acute (P < 0.009) and subacute stages (P < 0.005) with NAWM. In addition, NAA/Cho and Cho/Cr ratios were significantly different between lesions in the subacute stage and NAWM (P < 0.006, P < 0.007, respectively). ADEM lesions were characterized in the acute stage by restricted diffusion and in the subacute stage by free diffusion and a decrease in NAA/Cho ratios

  2. Segmentation and visual analysis of whole-body mouse skeleton microSPECT.

    Directory of Open Access Journals (Sweden)

    Artem Khmelinskii

    Full Text Available Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability. The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers (99mTc-methylene diphosphonate ((99mTc-MDP and (99mTc-hydroxymethane diphosphonate ((99mTc-HDP were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for "incomplete" data (large chunks of skeleton missing and for an intuitive exploration and comparison of multi-modal SPECT

  3. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation.

    Science.gov (United States)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (~15-20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate Ki and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final Ki parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion study

  4. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation

    International Nuclear Information System (INIS)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-01-01

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (∼15–20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate K i and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final K i parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion

  5. Automatic anatomy recognition in whole-body PET/CT images

    International Nuclear Information System (INIS)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.; Zhao, Liming

    2016-01-01

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  6. Automatic anatomy recognition in whole-body PET/CT images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huiqian [College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China and Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu; Odhner, Dewey; Tong, Yubing; Torigian, Drew A. [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Zhao, Liming [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 and Research Center of Intelligent System and Robotics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China)

    2016-01-15

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  7. Assessment of exposure to whole body vibration in Yazd city taxi drivers

    Directory of Open Access Journals (Sweden)

    F Samoori sakhvidi

    2016-11-01

    Full Text Available Assessment of exposure to whole body vibration in Yazd city taxi drivers Samoori-Sakhvidi F (MSc* Barkhordari A (PhD** Dehghani A (PhD*** Tavakoli-Manesh S (MSc**** *Corresponding Author: MSc Student in Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran ** Professor, Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran *** Professor, Department of Statistics and Epidemiology, Shahid Sadoughi University of Medical Sciences, Yazd, Iran **** MSc Student in Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran Abstract Introduction: One of the most common sources of whole body vibration are vehicles in which the driver is exposed to vibration caused by the vehicle and the road. Including the people who continuously exposure to whole-body vibration can be noted to taxi drivers. Taxi drivers during their work shift Encountered with numerous deleterious effects such as noise, vibration, air pollution, and psychological stress and long work shifts. Long-term exposure to whole body vibration in the taxi drivers can communicate with adverse effects such as reduce perception, annoyance, disturbance of vision and fine motor tasks, spinal cord injury, damage to the digestive and reproductive systems. The purpose of this study was cross - sectional study of whole body vibration exposure in Yazd city taxi drivers. Methods: This study was designed to evaluate exposure to whole body vibration in taxi drivers, vibration measurement Was carried out in 80 taxi from 3 vehicle (Samand-Peugeot 405 and Pridein 3 mileage groups, with 63 male drivers and 17 female drivers. parameters Including the vibration Weighing the acceleration frequency (rms, Equivalent acceleration (Aeq and vibration doseVDV in 3-axis was recorded. The results obtained were compared with the values recommended by the standard (ISO 2631-1. Results: The mean (rms acceleration

  8. Effect of whole body cryotherapy interventions on health-related quality of life in fibromyalgia patients: A randomized controlled trial.

    Science.gov (United States)

    Vitenet, M; Tubez, F; Marreiro, A; Polidori, G; Taiar, R; Legrand, F; Boyer, F C

    2018-02-01

    Although fibromyalgia syndrome (SFM) affects 2-4 percent of adults, research has not identified a preferred therapeutic option for patients worldwide yet. Based on recent findings, it can be expected that whole body cryotherapy can improve health-reported quality of life by alleviating the symptoms of musculoskeletal pain and fatigue. Our aim was to determine whether whole body cryotherapy only can result in improved perceived health and quality of life in fibromyalgia patients. 24 patients with fibromyalgia diagnosis were randomized into 2 groups (n=11 in the whole body cryotherapy group, n=13 in the control group). In the whole body cryotherapy group, 10 sessions of whole body cryotherapy were performed (in addition to usual care) in a standard cryotherapy room over a duration of 8days. Subjects in the control group did not change anything in their everyday activities. Quality of life was assessed just before and one month after treatment. Compared with the control group, patients in the whole body cryotherapy group reported significantly improved for health-reported quality of life. These effects lasted for at least one month following intervention. Based on these findings, whole body cryotherapy can be recommended as an effective clinically adjuvant approach in the improvement of health-related quality of life in fibromyalgia patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  10. Scanning personnel for internal deposition of radioactive material with personnel contamination whole body friskers and portal monitors

    International Nuclear Information System (INIS)

    Lobdell, J.L.

    1996-01-01

    The potential for using personnel contamination devices such as whole body friskers and portal monitors for internal contamination monitoring was evaluated. Internally deposited radioactive material is typically determined with whole body counting systems. Whole body counts have traditionally been performed on personnel when they report for work, on a periodic basis (i.e., annually), when an uptake is suspected, and on termination. These counts incur significant expense. The monitored personnel pass through whole body friskers and portal monitors daily. This investigation was performed to determine if the external contamination monitors could provide an alternative to the more Costly whole body counting. The ability to detect 1% of a DAC for critical radioisotopes was applied as a detection criteria for this investigation. The results of whole body counts were used to identify the typical internal contamination radionuclides. From this list, the radioisotopes that would be the most difficult to measure were identified. From this review, 60 Co and 131 I were determined to be the critical radionuclides. One percent of a DAC for each isotope was placed, one at a time, in a humanoid phantom. The phantom was placed in the whole body frisker and open-quotes countedclose quotes. The phantom was carried through the portal monitor at a speed equivalent to a person walking through the monitor. Frequency of detection was derived for both systems. Practical aspects of integrating this screening system with traditional internal dosimetry programs are discussed

  11. The influence of dietary and whole-body nutrient content on the excretion of a vertebrate consumer.

    Directory of Open Access Journals (Sweden)

    Christopher M Dalton

    Full Text Available In many contexts, nutrient excretion by consumers can impact ecosystems by altering the availability of limiting nutrients. Variation in nutrient excretion can be predicted by mass balance models, most of which are premised on two key ideas: (1 consumers maintain fixed whole-body nutrient content (i.e., %N and %P, so-called fixed homeostasis; (2 if dietary nutrients are not matched to whole-body nutrients, excesses of any nutrient are released as excretion to maintain fixed homeostasis. Mass balance models thus predict that consumer excretion should be positively correlated with diet nutrients and negatively correlated with whole-body nutrients. Recent meta-analyses and field studies, however, have often failed to find these expected patterns, potentially because of a confounding influence-flexibility in whole-body nutrient content with diet quality (flexible homeostasis. Here, we explore the impact of flexible homeostasis on nutrient excretion by comparing the N and P excretion of four genetically diverged Trinidadian guppy (Poecilia reticulata populations when reared on diets of variable P content. As predicted by mass balance, P excretion increased on the high-P diet, but, contrary to the notion of fixed homeostasis, guppy whole-body %P also increased on the high-P diet. While there was no overall correlation between excretion nutrients and whole-body nutrients, when the effect of diet on both whole-body and excretion nutrients was included, we detected the expected negative correlation between whole-body N:P and excretion N:P. This last result suggests that mass balance can predict excretion rates within species, but only if dietary effects on whole-body nutrient content are controlled. Flexible homeostasis can obscure patterns predicted by mass balance, creating an imperative to accurately capture an organism's diet quality in predicting its excretion rate.

  12. Comparison of a new whole-body continuous-table-movement protocol versus a standard whole-body MR protocol for the assessment of multiple myeloma

    International Nuclear Information System (INIS)

    Weckbach, S.; Michaely, H.J.; Schoenberg, S.O.; Dinter, D.J.; Stemmer, A.

    2010-01-01

    To evaluate a whole body (WB) continuous-table-movement (CTM) MR protocol for the assessment of multiple myeloma (MM) in comparison to a step-by-step WB protocol. Eighteen patients with MM were examined at 1.5T using a WB CTM protocol (axial T2-w fs BLADE, T1-w GRE sequence) and a step-by-step WB protocol including coronal/sagittal T1-w SE and STIR sequences as reference. Protocol time was assessed. Image quality, artefacts, liver/spleen assessability, and the ability to depict bone marrow lesions less than or greater than 1 cm as well as diffuse infiltration and soft tissue lesions were rated. Potential changes in the Durie and Salmon Plus stage and the detectability of complications were assessed. Mean protocol time was 6:38 min (CTM) compared to 24:32 min (standard). Image quality was comparable. Artefacts were more prominent using the CTM protocol (P = 0.0039). Organ assessability was better using the CTM protocol (P < 0.001). Depiction of bone marrow and soft tissue lesions was identical without a staging shift. Vertebral fractures were not detected using the CTM protocol. The new protocol allows a higher patient throughput and facilitates the depiction of extramedullary lesions. However, as long as vertebral fractures are not detectable, the protocol cannot be safely used for clinical routine without the acquisition of an additional sagittal sequence. (orig.)

  13. Whole Body Vibration Retards Progression of Atherosclerosis via Insulin-Like Growth Factor 1 in Apolipoprotein E-Deficient Mice

    Directory of Open Access Journals (Sweden)

    He Wu

    2018-01-01

    Full Text Available Whole body vibration (WBV has a marked impact on lipid metabolism and the endocrine system, which is related to the progression of atherosclerosis (AS. To investigate the effects of WBV, we measured the atherosclerotic plaque area of apolipoprotein E-knockout (ApoE−/− AS mice, which were trained by WBV (15 Hz, 30 min for 12 weeks. Simultaneously, serum levels of lipids, insulin-like growth factor 1 (IGF-1, insulin-like growth factor 1 receptor (IGF-1R, interleukin 6 (IL-6, and the mRNA and protein levels of the same in the aorta were compared between the control and WBV groups. The results indicated that WBV significantly reduced the atherosclerotic plaque area with lower very low-density lipoprotein (VLDL and oxidized low-density lipoprotein (ox-LDL in the blood. Moreover, the levels of IGF-1 in serum and expression of IL-6, IGF-1R, and p-IGF-1R protein in the mice aorta decreased significantly in the WBV group. In addition, we found that serum IGF-1 in mice increased to the highest concentration in 30 min after WBV for 10, 30, 60, and 120 minutes. These results suggested that appropriate WBV may delay the progression of AS, which was associated with acutely elevated serum IGF-1 and lower levels of IGF-1 and IL-6 in the aorta for long-term treatment.

  14. Whole Body Vibration Retards Progression of Atherosclerosis via Insulin-Like Growth Factor 1 in Apolipoprotein E-Deficient Mice.

    Science.gov (United States)

    Wu, He; Zhang, Yibo; Yang, Xuan; Li, Xian; Shao, Zhenya; Zhou, Zipeng; Li, Yuanlong; Pan, Shuwen; Liu, Chang

    2018-01-01

    Whole body vibration (WBV) has a marked impact on lipid metabolism and the endocrine system, which is related to the progression of atherosclerosis (AS). To investigate the effects of WBV, we measured the atherosclerotic plaque area of apolipoprotein E-knockout (ApoE -/- ) AS mice, which were trained by WBV (15 Hz, 30 min) for 12 weeks. Simultaneously, serum levels of lipids, insulin-like growth factor 1 (IGF-1), insulin-like growth factor 1 receptor (IGF-1R), interleukin 6 (IL-6), and the mRNA and protein levels of the same in the aorta were compared between the control and WBV groups. The results indicated that WBV significantly reduced the atherosclerotic plaque area with lower very low-density lipoprotein (VLDL) and oxidized low-density lipoprotein (ox-LDL) in the blood. Moreover, the levels of IGF-1 in serum and expression of IL-6, IGF-1R, and p-IGF-1R protein in the mice aorta decreased significantly in the WBV group. In addition, we found that serum IGF-1 in mice increased to the highest concentration in 30 min after WBV for 10, 30, 60, and 120 minutes. These results suggested that appropriate WBV may delay the progression of AS, which was associated with acutely elevated serum IGF-1 and lower levels of IGF-1 and IL-6 in the aorta for long-term treatment.

  15. Spontaneous cell-mediated cytolysis by peripheral blood cells obtained from whole-body chronically irradiated beagle dogs

    International Nuclear Information System (INIS)

    Dyck, J.A.; Shifrine, M.; Klein, A.K.; Rosenblatt, L.S.; Kawakami, T.

    1986-01-01

    The level of natural killer (NK) activity of continuously gamma-irradiated (whole body) beagle dogs and their nonirradiated controls was studied. For analytical purposes, irradiated dogs were segregated into groups according to their clinical status: clinically normal, hypocellular, or with acute non-lymphocytic leukemia. Since unirradiated control animals exhibited a wide range of NK responses, the data from each irradiated animal were compared to its own age-matched or litter-matched unirradiated control. Of the eight clinically normal irradiated dogs (median = 146% activity of control) only one animal had a NK activity lower than that of its control. The hypocellular group (n = 5, median = 21.8% of control) and the leukemic group (n = 4, median = 52.5% of control) each contained one responder with higher activity than its control. The difference between the percentage of control of the clinically normal and clinically abnormal dogs was found to be significant (P less than 0.05). There is a negative correlation between the NK results obtained and the total accumulated dose of radiation at the time of sampling (correlation coefficient = -0.739, P less than 0.01), suggesting a radiation effect upon natural killer activity, which is evidence by enhancement at lower doses and depression at higher doses of irradiation

  16. A clinical trial comparing the responses of animal tumors receiving heat sensitizing drugs prior to whole body hyperthermia

    International Nuclear Information System (INIS)

    Klein, M.K.; Forsyth, K.; Dewhirst, M.W.; Fuller, D.J.M.

    1984-01-01

    Whole body hyperthermia (WBH) has rarely been found effective in inducing complete tumor responses. Recent in vitro studies showing that heat sensitizion is possible have renewed interest in this field. In this protocol, WBH is induced via a commercially available inductive device and maintained at 42 0 C for thirty minutes. The heat sensitizing drugs, difluoromethylornithine (DFMO) methylglyoxal bis (guanylhydrazone) (MGBG) are administered 48 hours before, in accordance with in vitro studies. Goals of the study include evaluation of normal tissue toxicity and tumor response. Two normal dogs were treated to study acute toxicities before inception of the clinical trial. The gastrointestinal and hematopoietic systems were used to monitor toxicities using systems review and serial bloodwork. These studies and preliminary clinical results of observed tumor regression in dogs with lymphomas are discussed. Consistent changes in all patients included elevations in liver enzymes, creatine phosphokinase (CPK), and white blood cell counts, as well as, decreases in platelet counts. All changes were transient and clinical signs were not associated with them. Tumor volume reductions from 25% to 74% have been documented

  17. Effect of Hippophae leaves on neurotransmitters and hematological parameters in whole body irradiated rats

    International Nuclear Information System (INIS)

    Gupta, Vanita; Prasad, Jagdish; Madhu Bala

    2012-01-01

    Till date no approved radio-protective agent is available world over. WR-2721 had severe side effects and was behaviourally toxic even at sub-lethal doses of ionizing radiation. Seabuckthorn (Hippophae rhamnoides L.) is known for its nutraceutical and therapeutic values. Our studies demonstrated that treatment with leaves of H. rhamnoides rendered > 90% whole body radioprotection in 60 Co-g-irradiated (10 Gy) mice population in comparison to 100% death in non-Hippophae treated irradiated (10 Gy) mice population. Our studies also demonstrated that treatment with leaves of H. rhamnoides prevented conditioned taste aversion (CTA) in irradiated (2 Gy) Sprague-Dawley rats. The present study was planned to evaluate the effects of aqueous extract of Hippophae leaves on changes in levels of neurotransmitters ((acetylcholine esterase (AChE) and dopamine (DA)) in plasma and brain, haematological parameters in blood/plasma; and brain histology in Sprague-Dawley rats showing CTA after 60 Co-g-irradiation (2 Gy). The results showed that whole body 60 Co-g-irradiation (2 Gy) (i) increased the levels of Ach, Eepinephrine (E) and norepinephrine (NE); oxidative stress (MDA and NO), and (ii) decreased the levels of DA; WBC counts and RBC counts and antioxidants (GSH), in comparison to untreated control. Treatment with 12 mg/kg b.w. drug concentration, prior to irradiation significantly (p<0.05) (i) decreased the levels of AChE, E and NE, and MDA and NO levels in plasma and brain, and (ii) increased the WBC counts; RBC counts and levels of antioxidants (GSH), in comparison to radiation control group. Histological changes in brain were also recorded. The results demonstrated that Hippophae leaves extract had neuro-protective and reduced oxidative stress in brain of whole body irradiated mice and could be, thereby contributing to behavioural protection. (author)

  18. Catecholamine levels in sheep hypothalamus, hypophysis and adrenals following whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Pastorova, B.; Arendarcik, J.; Molnarova, M.

    1985-01-01

    Changes were studied in the levels of catecholamines and L-DOPA in the control system of the reproduction cycle (hypothalamus, hypophysis) and in the adrenal glands of sheep after whole-body irradiation with 60 Co at a total dose of 6.7 Gy for seven days. The output of the radiation source was 0.039 Gy/h. The catecholamines (noradrenaline, dopamine and adrenaline) and L-DOPA were determined after separation from the tissues by the method of spectral fluorometry. After whole-body exposure to gamma radiation, noradrenaline dropped in the hypothalamus in comparison with the control group, most significantly in the rostral (by 74.2%) and caudal (by 40%) parts. A similar drop was also observed in dopamine, the concentrations of which decreased in the rostral hypothalamus by 60%. Adrenaline showed a drop in the hypothalamus, most significant in the caudal region (by 62%). Consequently, the level of the precursor of the synthesis of catecholamines and L-DOPA changed and showed in the studied regions of the hypothalamus significantly lower levels than in the control group. As regards the hypophysis, after irradiation no significant changes in the levels of noradrenaline and adrenaline were recorded, however, dopamine and L-DOPA dropped significantly (P<0.01). The exposure to gamma radiation also causes a decrease in the concentrations of catecholamines and L-DOPA in the adrenal glands of sheep, most significantly in noradrenaline (by 61%). It was thus found that whole-body irradiation of sheep with a dose of 6.7 Gy results in a significant decrease in the level of catecholamines in the hypothalamus, hypophysis and adrenal glands, which is probably in relation to the failure of synthesis and degradation of catecholamines and to the total organism injury

  19. Distribution of plutonium and americium in whole bodies donated to the United States Transuranium Registry

    International Nuclear Information System (INIS)

    McInroy, J.F.; Kathren, R.L.; Swint, M.J.

    1989-01-01

    Radiochemical analysis of whole body donations from six former nuclear industry workers 30 or more years post-exposure revealed about 45% of the total body deposition of 239 Pu and 35% of the 241 Am in the respiratory tract of the four cases with inhalation exposure. These proportions are greater than predicted by the current ICRP lung model. Exclusive of the respiratory tract, the mean fractional systemic deposition of 239 Pu in the tissues of five whole bodies was: liver 35.4% ± 12.5%; skeleton 53.7% ± 12.5%; striated muscle 6.5% ± 1.8% and all other organs and tissues 4.4% ± 1.7%. For 241 Am, the comparable values in four cases were liver 6.5% ± 4.8%; skeleton 73.5% ± 12.4%; muscle 14.3% ± 7.6%; and all other tissues and organs 6.65% ± 4.2%. The systemic distribution of 239 Pu was generally consistent with ICRP Publication 30. A significant fraction of both nuclides was retained in the muscle and other soft tissues which serve as long-term storage depots. Initial fractionation of 241 Am between skeleton and liver is consistent with the 50:30 ratio proposed in ICRP Publication 48 assuming an effective clearance half-time from the liver of about 2 y. Estimates of 239 Pu deposition made on the basis of urinalysis results in vivo were typically greater than the observed deposition measured in the tissues of the whole body after death. (author)

  20. Turnover of whole body proteins and myofibrillar proteins in middle-aged active men

    International Nuclear Information System (INIS)

    Zackin, M.; Meredith, C.; Frontera, W.; Evans, W.

    1986-01-01

    Endurance-trained older men have a higher proportion of lean tissue and greater muscle cell oxidative capacity, reversing age-related trends and suggesting major changes in protein metabolism. In this study, protein turnover was determined in 6 middle-aged (52+/-1 yr) men who were well trained (VO 2 max 55.2+/-5.0 ml O 2 /kg.min) and lean (body fat 18.9+/-2.8%, muscle mass 36.6+/-0.6%). The maintained habitual exercise while consuming 0.6, 0.9 or 1.2 g protein/kg.day for 10-day periods. N flux was measured from 15 N in urea after oral 15 N-glycine administration. Myofibrillar protein breakdown was estimated from urinary 3-methyl-histidine. Dietary protein had no effect on turnover rates, even when N balance was negative. Whole body protein synthesis was 3.60+/-0.12 g/kg.day and breakdown was 3.40+/-0.14 g/kg.day for all N intakes. Whole body protein flux, synthesis and breakdown were similar to values reported for sedentary young (SY) or sedentary old (SO) men on comparable diets. 3-me-his (3.67+/-0.14 μmol/kg.day) was similar to values reported for SY but higher (p<0.01) than for SO. Myofibrillar protein breakdown per unit muscle mass (185+/-7 μmol 3-me-his/g creatinine) was higher (p<0.01) than for SY or SO. In active middle-aged men, myofibrillar proteins may account for a greater proportion of whole body protein turnover, despite an age-related reduction in muscle mass

  1. Retrospective analysis of whole-body multislice computed tomography findings taken in trauma patients

    Directory of Open Access Journals (Sweden)

    Ozlem Bingol

    2015-09-01

    Full Text Available Objectives: Using whole-body multislice computed tomography (MSCT excessively or with irrelevant indications can be seen in many centers. The aim of this study was to analyze retrospectively the MSCT findings in trauma patients admitted to the emergency department. Methods: Records of the patients who have applied to the emergency department due to blunt trauma in a 12 month period and whose whole body MSCT images have been taken, were evaluated using the “Nucleus Medical Information System”. Results: The most frequent type of trauma was traffic accidents in 61.4%, falling down from the height in 22.4%, and motorcycle accidents in 11.4% of patients. Of the patients, 25.2% were discharged from the emergency, while 73.8% were hospitalized. At least one CT findings associated with trauma was present in 61.4% of our patients. Pathological findings in MSCT were most frequently detected in the head and face (35.3% and thoracic (28.6% regions, respectively. The most common finding in the head and face region was fractures. The most common pathological findings in the thoracic region were pulmonary contusion and rib fractures. A significant relationship was detected between trauma type and spinal MSCT result (p < 0.001. In a large percentage of the patients, MSCT findings were normal in the abdominal region and genitourinary system. Vertebral fractures were most frequently detected in the thoracolumbar region. Conclusions: In our study, our rate of negative CT was found to be 38.6%, which is a higher ratio compared to other studies conducte on this topic. Keywords: Emergency, Trauma, Whole-body multislice computed tomography

  2. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L. [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Bamberg, Fabian [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); University Hospital Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lochner, Elena [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); Findeisen, Hannes M. [University Hospital Muenster, Department of Cardiology and Angiology, Muenster (Germany); Parhofer, Klaus G. [Ludwig Maximilians University, Klinikum Grosshadern, Department of Internal Medicine II, Munich (Germany); Schoenberg, Stefan O. [University Medical Center Mannheim, Department of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2016-05-15

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  3. Whole-Body Cryotherapy in Athletes: From Therapy to Stimulation. An Updated Review of the Literature.

    Science.gov (United States)

    Lombardi, Giovanni; Ziemann, Ewa; Banfi, Giuseppe

    2017-01-01

    Nowadays, whole-body cryotherapy is a medical physical treatment widely used in sports medicine. Recovery from injuries (e.g., trauma, overuse) and after-season recovery are the main purposes for application. However, the most recent studies confirmed the anti-inflammatory, anti-analgesic, and anti-oxidant effects of this therapy by highlighting the underlying physiological responses. In addition to its therapeutic effects, whole-body cryotherapy has been demonstrated to be a preventive strategy against the deleterious effects of exercise-induced inflammation and soreness. Novel findings have stressed the importance of fat mass on cooling effectiveness and of the starting fitness level on the final result. Exposure to the cryotherapy somehow mimics exercise, since it affects myokines expression in an exercise-like fashion, thus opening another possible window on the therapeutic strategies for metabolic diseases such as obesity and type 2 diabetes. From a biochemical point of view, whole-body cryotherapy not always induces appreciable modifications, but the final clinical output (in terms of pain, soreness, stress, and post-exercise recovery) is very often improved compared to either the starting condition or the untreated matched group. Also, the number and the frequency of sessions that should be applied in order to obtain the best therapeutic results have been deeply investigated in the last years. In this article, we reviewed the most recent literature, from 2010 until present, in order to give the most updated insight into this therapeutic strategy, whose rapidly increasing use is not always based on scientific assumptions and safety standards.

  4. Forearm cutaneous vascular and sudomotor responses to whole body passive heat stress in young smokers.

    Science.gov (United States)

    Moyen, Nicole E; Anderson, Hannah M; Burchfield, Jenna M; Tucker, Matthew A; Gonzalez, Melina A; Robinson, Forrest B; Ganio, Matthew S

    2015-07-01

    The purpose of this study was to compare smokers and nonsmokers' sudomotor and cutaneous vascular responses to whole body passive heat stress. Nine regularly smoking (SMK: 29 ± 9 yr; 10 ± 6 cigarettes/day) and 13 nonsmoking (N-SMK: 27 ± 8 yr) males were passively heated until core temperature (TC) increased 1.5°C from baseline. Forearm local sweat rate (LSR) via ventilated capsule, sweat gland activation (SGA), sweat gland output (SGO), and cutaneous vasomotor activity via laser-Doppler flowmetry (CVC) were measured as mean body temperature increased (ΔTb) during passive heating using a water-perfused suit. Compared with N-SMK, SMK had a smaller ΔTb at the onset of sweating (0.52 ± 0.19 vs. 0.35 ± 0.14°C, respectively; P = 0.03) and cutaneous vasodilation (0.61 ± 0.21 vs. 0.31 ± 0.12°C, respectively; P body heating was higher in N-SMK vs. SMK (1.00 ± 0.13 vs. 0.79 ± 0.26 mg·cm(-2)·min(-1); P = 0.03), which was likely a result of higher SGO (8.94 ± 3.99 vs. 5.94 ± 3.49 μg·gland(-1)·min(-1), respectively; P = 0.08) and not number of SGA (104 ± 7 vs. 121 ± 9 glands/cm(2), respectively; P = 0.58). During whole body passive heat stress, smokers had an earlier onset for forearm sweating and cutaneous vasodilation, but a lower local sweat rate that was likely due to lower sweat output per gland. These data provide insight into local (i.e., forearm) thermoregulatory responses of young smokers during uncompensatory whole body passive heat stress. Copyright © 2015 the American Physiological Society.

  5. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  6. Analysis of annual exposure of private farmers to noise and whole body vibration

    Directory of Open Access Journals (Sweden)

    Leszek Solecki

    2012-06-01

    Full Text Available Based on a literature review for the period of 1982– 2011, an analysis was performed of studies by various researchers concerning the exposure of private farmers to noise and vibration of the whole body with particular consideration of the annual exposure to these factors. The main sources of noise occurring in agriculture are: agricultural tractors mounted with a set of farm machinery, self-propelled machines, machinery for the production of fodder and workshop equipment. The review of literature showed that the highest values of equivalent exposure to noise (EA, T or noise doses (d were noted during the summer-autumn season and in spring. Mean noise levels for the entire year (of over 90 dB-A, considerably exceeded permissible values.The primary sources of the whole body vibration are agricultural vehicles including agricultural tractors of various types and self-propelled agricultural vehicles. In these vehicles vibration transmitted from the seat to the whole body is of basic importance. The measurements of vibration acceleration indicated that mechanical vibration on seats was produced while performing following activities: hay tedding and raking, sowing of fertilizers, aggregation of soil, grass mowing and cultivation. All of them may create a considerable health risk. These work activities are performed at elevated working speeds of tractors, most often along with hardened or uneven surfaces. In relation to the standard values (A(840.8 m/s2, the mean daily vibration acceleration values remain below the permissible levels during all months of the year. However, considering the occurrence of mechanical shocks of high values (above the Maximum Acceptable Intensity on agricultural vehicles there is a high risk for the spine problems among operators of agricultural vehicles.

  7. Can segmental model reductions quantify whole-body balance accurately during dynamic activities?

    Science.gov (United States)

    Jamkrajang, Parunchaya; Robinson, Mark A; Limroongreungrat, Weerawat; Vanrenterghem, Jos

    2017-07-01

    When investigating whole-body balance in dynamic tasks, adequately tracking the whole-body centre of mass (CoM) or derivatives such as the extrapolated centre of mass (XCoM) can be crucial but add considerable measurement efforts. The aim of this study was to investigate whether reduced kinematic models can still provide adequate CoM and XCoM representations during dynamic sporting tasks. Seventeen healthy recreationally active subjects (14 males and 3 females; age, 24.9±3.2years; height, 177.3±6.9cm; body mass 72.6±7.0kg) participated in this study. Participants completed three dynamic movements, jumping, kicking, and overarm throwing. Marker-based kinematic data were collected with 10 optoelectronic cameras at 250Hz (Oqus Qualisys, Gothenburg, Sweden). The differences between (X)CoM from a full-body model (gold standard) and (X)CoM representations based on six selected model reductions were evaluated using a Bland-Altman approach. A threshold difference was set at ±2cm to help the reader interpret which model can still provide an acceptable (X)CoM representation. Antero-posterior and medio-lateral displacement profiles of the CoM representation based on lower limbs, trunk and upper limbs showed strong agreement, slightly reduced for lower limbs and trunk only. Representations based on lower limbs only showed less strong agreement, particularly for XCoM in kicking. Overall, our results provide justification of the use of certain model reductions for specific needs, saving measurement effort whilst limiting the error of tracking (X)CoM trajectories in the context of whole-body balance investigation. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2015-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaITl (8 x 4”), and thyroid one, NaITl (3 x 3”). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that was not exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2010 to December 2014, approximately 4500 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  9. Calibration of the LDI/CDTN Whole Body Counter using three physical phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, F.G.; Fonseca, T.C.F. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dep. de Engenharia Nuclear; Mendes, B.M.; Silva, T.A. da; Lacerda, M.A.S.; Pinto, J.R.; Prates, S.; Filho, N.N.A., E-mail: fgpaiva92@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte/MG (Brazil); Dantas, A.L.A.; Dantas, B.M. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine monitoring of internal contamination of the Individuals Occupationally Exposed (IOEs) at the Unit for Research and Production of Radiopharmaceuticals (UPPR/CDTN), the Research Reactor TRIGA-IPR-R1/CDTN and other workplaces of the institute where there is a risk of accidental intakes. Additionally, LDI supports the Institute of Radiation Protection and Dosimetry (IRD/CNEN) to attend radiological emergencies. The determination of photon emitting radionuclides in the human body requires the use of calibration techniques in different counting geometries for converting the count rates into activity in organs and tissues. This paper presents and discusses the calibration of the LDI/CDTN Whole Body Counter (WBC) using a standard BOMAB phantom (Bottle Mannequin Absorber) compared to a home-made phantom produced with Polyethylene Terephthalate bottles (PET). Initially, the BOMAB was filled with a cocktail containing {sup 60}Co, {sup 137}Cs and {sup 133}Ba. The phantom was counted at the LDI whole body counter and an Efficiency x Energy curve was obtained. Subsequently the PET-BOMAB was filled with the same standard source and a second curve was determined. The efficiency values in each region of interest as well as the shape of both curves were found to be equivalent. The results validate the use of the PET-BOMAB for the calibration of whole body geometry applied to the measurement of high energy photon emitting radionuclides in the energy region evaluated in this work. (author)

  10. Evaluation of whole-body MR to CT deformable image registration.

    Science.gov (United States)

    Akbarzadeh, A; Gutierrez, D; Baskin, A; Ay, M R; Ahmadian, A; Riahi Alam, N; Lövblad, K O; Zaidi, H

    2013-07-08

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based on B-spline transformation was performed using optimized parameters of the elastix package based on the Insight Toolkit (ITK) framework. Twenty-eight (17 male and 11 female) clinical studies were used in this work. The registration was evaluated using anatomical landmarks and segmented organs. In addition to 16 anatomical landmarks, three key organs (brain, lungs, and kidneys) and the entire body volume were segmented for evaluation. Several parameters--such as the Euclidean distance between anatomical landmarks, target overlap, Dice and Jaccard coefficients, false positives and false negatives, volume similarity, distance error, and Hausdorff distance--were calculated to quantify the quality of the registration algorithm. Dice coefficients for the majority of patients (> 75%) were in the 0.8-1 range for the whole body, brain, and lungs, which satisfies the criteria to achieve excellent alignment. On the other hand, for kidneys, Dice coefficients for volumes of 25% of the patients meet excellent volume agreement requirement, while the majority of patients satisfy good agreement criteria (> 0.6). For all patients, the distance error was in 0-10 mm range for all segmented organs. In summary, we optimized and evaluated the accuracy of an MR to CT deformable registration algorithm. The registered images constitute a useful 3D whole-body MR-CT atlas suitable for the development and evaluation of novel MR-guided attenuation correction procedures on hybrid PET-MR systems.

  11. Accuracy of 24-h whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Scullion, J.E.; Bessent, R.; Cuthbert, G.F.

    1982-01-01

    The 24-h whole-body retention (WBR) of diphosphonate was a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r=0.998, R<0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. A phantom was used to assess the possible error introduced by redistribution of tracer. The net whole-body count of the phantom representing the 24-h distribution was 98% of that of a uniform phantom. Ten subjects were counted twice within a few minutes to study the effect of repositioning, and showed a mean difference between counts of only 0.8%. Eleven subjects with traumatic fractures were studied to assess the possible contribution of focal lesions to WBR. It was found that nine subjects had normal values for WBR, while two had minimally elevated results. Twenty patients with renal disease but no apparent skeletal disease were also studied to assess the possible contribution of soft-tissue retention to WBR. A significant correlation between serum creatinine and WBR was found (r=0.72, P<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/1. It is suggested that WBR measurement is accurate and the technique is hgihly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is the normal range then WBR can be assumed to reflect skeletal metabolism without further concern as to renal function. (orig.)

  12. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2013-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaIT1 (8x4″), and thyroid one, NaIT1 (3x3″). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that wasn't exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2007 to December 2012, approximately 6700 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  13. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    International Nuclear Information System (INIS)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L.; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M.; Parhofer, Klaus G.; Schoenberg, Stefan O.

    2016-01-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  14. A case of acute exacerbation of idiopathic pulmonary fibrosis after proton beam therapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Nagano, Tatsuya; Kotani, Yoshikazu; Fujii, Osamu

    2012-01-01

    There have been no reports describing acute exacerbations of idiopathic pulmonary fibrosis after particle radiotherapy for non-small cell lung cancer. The present study describes the case of a 76-year-old Japanese man with squamous cell carcinoma of the lung that relapsed in the left upper lobe 1 year after right upper lobectomy. He had been treated with oral prednisolone 20 mg/day every 2 days for idiopathic pulmonary fibrosis, and the relapsed lung cancer was treated by proton beam therapy, which was expected to cause the least adverse effects on the idiopathic pulmonary fibrosis. Fifteen days after the initiation of proton beam therapy, the idiopathic pulmonary fibrosis exacerbated, centered on the left upper lobe, for which intensive steroid therapy was given. About 3 months later, the acute exacerbation of idiopathic pulmonary fibrosis had improved, and the relapsed lung cancer became undetectable. Clinicians should be aware that an acute exacerbation of idiopathic pulmonary fibrosis may occur even in proton beam therapy, although proton beam therapy appears to be an effective treatment option for patients with idiopathic pulmonary fibrosis. (author)

  15. System for whole body imaging and count profiling with a scintillation camera

    International Nuclear Information System (INIS)

    Kaplan, E.; Cooke, M.B.D.

    1976-01-01

    The present invention relates to a method of and apparatus for the radionuclide imaging of the whole body of a patient using an unmodified scintillation camera which permits a patient to be continuously moved under or over the stationary camera face along one axis at a time, parallel passes being made to increase the dimension of the other axis. The system includes a unique electrical circuit which makes it possible to digitally generate new matrix coordinates by summing the coordinates of a first fixed reference frame and the coordinates of a second moving reference frame. 19 claims, 7 figures

  16. Influence of whole-body irradiation on calcium and phosphate homeostasis in the rat

    International Nuclear Information System (INIS)

    Pento, J.T.; Kenny, A.D.

    1975-01-01

    Previous irradiation studies have revealed marked alterations in calcium metabolism. Moreover, the maintenance of calcium homeostasis with parathyroid hormone or calcium salts has been reported to reduce radiation lethality. Therefore, the present study was designed to evaluate the influence of irradiation on calcium homeostasis in the rat. Nine hundred rad of whole-body irradiation produced a significant depression of both plasma calcium and phosphate at 4 days postirradiation. This effect of irradiation was observed to be dose-dependent over a range of 600 to 1200 rad, and possibly related to irradiation-induced anorexia. The physiological significance of these observations is discussed

  17. Theoretical assessment of whole body counting performances using numerical phantoms of different gender and sizes.

    Science.gov (United States)

    Marzocchi, O; Breustedt, B; Mostacci, D; Zankl, M; Urban, M

    2011-03-01

    A goal of whole body counting (WBC) is the estimation of the total body burden of radionuclides disregarding the actual position within the body. To achieve the goal, the detectors need to be placed in regions where the photon flux is as independent as possible from the distribution of the source. At the same time, the detectors need high photon fluxes in order to achieve better efficiency and lower minimum detectable activities. This work presents a method able to define the layout of new WBC systems and to study the behaviour of existing ones using both detection efficiency and its dependence on the position of the source within the body of computational phantoms.

  18. Urinary excretion of phthalates and paraben after repeated whole-body topical application in humans

    DEFF Research Database (Denmark)

    Janjua, Nadeem Rezaq; Frederiksen, Hanne; Skakkebaek, Niels E

    2008-01-01

    Diethyl phthalate (DEP), dibutyl phthalate (DBP) and butyl paraben (BP) are man-made chemicals used in personal care products, such as lotions and creams. Exposure to these chemicals causes a variety of adverse reproductive outcomes in animal studies. Humans can be exposed to these chemicals...... were given a whole body topical application of basic cream 2 mg/cm(2) (control week) and then a cream containing 2% (w/w) of DEP, DBP and BP each (treatment week) daily. Twenty-four-hour urine samples were collected. Urinary total, and unconjugated BP, monoethyl phthalate (MEP) and monobutyl phthalate...

  19. Response of peripheral leucocytes to whole body irradiation and vitamin E treatment in white leghorn chick

    International Nuclear Information System (INIS)

    Rana, K.; Malhotra, N.

    1993-01-01

    Radiation induced changes in peripheral blood leucocytes in 1 day old male white leghorn chicks were studied after whole body exposure to 2.25 Gy dose of gamma radiation at the rate of 0.50 Gy/sec with and without vitamin E. The changes in total leucocyte counts, lymphocytes and heterophils were observed at 1,3,5,7,14 and 28 days postirradiation. A pronounced leucocytopenia was noted in the initial post-irradiation period. The lymphocytes and heterophils showed a reciprocal relationship after radiation. With vitamin E treatment, considerable and faster recovery was noticed in the leucocytes after irradiation. (author). 16 refs., 3 figs

  20. [Segmentation of whole body bone SPECT image based on BP neural network].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; He, Yuanlie; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2007-10-01

    In this paper, BP neural network is used to segment whole body bone SPECT image so that the lesion area can be recognized automatically. For the uncertain characteristics of SPECT images, it is hard to achieve good segmentation result if only the BP neural network is employed. Therefore, the segmentation process is divided into three steps: first, the optimal gray threshold segmentation method is employed for preprocessing, then BP neural network is used to roughly identify the lesions, and finally template match method and symmetry-removing program are adopted to delete the wrongly recognized areas.

  1. Plasma norepinephrine in humans: limitations in assessment of whole body norepinephrine kinetics and plasma clearance

    DEFF Research Database (Denmark)

    Christensen, N J; Henriksen, Jens Henrik Sahl

    1989-01-01

    ]IP and 131I-hippurate, whole body clearance from plasma of [3H]NE, as obtained from infusion rate divided by plasma concentration of tracer [1.74 +/- 0.64 (SD) 1/min] was significantly higher than the value obtained by total tracer infusion divided by total plasma area of tracer (1.27 +/- 0.51, P less than 0...... irreversible removal of NE, is smaller than previously estimated due to recycling through the plasma space. Attention has been drawn to limitations of [3H]NE kinetics....

  2. Principle and preliminary results of the whole-body scintigraphic unit Omniview

    International Nuclear Information System (INIS)

    Methlin, G.; Jung, G.M.; Gerard, G.

    The Picker Company has recently launched a system adapted to its Dynacamera for the production of whole-body scintigraphs. For the last few months the radioisotopes service of the Strasbourg Anti-Cancer Centre has been in possession of such a system, intended mainly for systematic research on metastases, especially of the bone, and on the degree of extension of tumours. On the basis of the short experience so far acquired the report is limited to an outline of the working principle of this device, the presentation of preliminary documents and a few critical remarks summing up first impressions [fr

  3. Hypodontia in the beagle after perinatal whole-body 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Lee, A.C.; Angleton, G.M.; Benjamin, S.A.

    1989-01-01

    As part of a long-term study to evaluate health effects of pre- and postnatal irradiation, dental development was examined. Beagles were irradiated in utero at 8, 28, or 55 days postcoitus or postnatally at 2, 70, or 365 days postpartum. Whole-body 60 Co gamma radiation doses ranged from 0 to 3.8 Gy. There was an age-dependent dose-related increase in premolar hypodontia for animals irradiated at 55 days postcoitus or 2 days postpartum with doses of 0.83 Gy or higher and for those irradiated at 28 days postcoitus with 1.2 Gy or higher

  4. Semi-portable whole body counter deployable during post-radiological accident

    International Nuclear Information System (INIS)

    Panchal, C.G.; Bansode, P.Y.; Vinod, M.; Sarade, Bhagyashree; Jain, R.K.; Jakati, R.K.; Pithawa, C.K.

    2012-01-01

    A versatile whole body counter with the state of art electronics has been indigenously designed and developed which can be readily deployed for use during nuclear emergency. This instrument is designed to quickly identify and quantify the activity of high energy photon emitters accumulated particularly in vital organs like thyroid, lungs besides the body of the victims of the radiological incident or accident. Special features of the instruments are swivel type detectors assembly mountable on a wall or table top and detachable collimator configurable to assess the internal contamination selectively to meet protective measures of the radiological accidents, mechanically rugged and functionally reliable to perform in contaminated environmental field conditions. (author)

  5. Whole-body effective half-lives for radiolabeled antibodies and related issues

    International Nuclear Information System (INIS)

    Kaurin, D.G.L.; Carsten, A.L.; Baum, J.W.; Barber, D.E.

    1996-08-01

    Radiolabeled antibodies (RABs) are being developed and used in medical imaging and therapy in rapidly increasing numbers. Data on the whole body half effective half-lives were calculated from external dose rates obtained from attending physicians and radiation safety officers at participating institutions. Calculations were made using exponential regression analysis of data from patients receiving single and multiple administrations. Theses data were analyzed on the basis of age, sex, isotope label, radiation energy, antibody type, disease treated, administration method, and number of administrations

  6. Quantification of whole-body bradykinesia in Parkinson's disease participants using multiple inertial sensors.

    Science.gov (United States)

    Memar, Sara; Delrobaei, Mehdi; Pieterman, Marcus; McIsaac, Kenneth; Jog, Mandar

    2018-04-15

    Bradykinesia (slowness of movement) is a common motor symptom of Parkinson's disease (PD) that can severely affect quality of life for those living with the disease. Assessment and treatment of PD motor symptoms largely depends on clinical scales such as the Unified Parkinson's Disease Rating Scale (UPDRS). However, such clinical scales rely on the visual assessment by a human observer, naturally resulting in inter-rater variability. Although previous studies have developed objective means for measuring bradykinesia in PD patients, their evaluation was restricted by the type of movement and number of joints assessed. These studies failed to provide a more comprehensive, whole-body evaluation capable of measuring multiple joints simultaneously. This study utilizes wearable inertial measurement units (IMUs) to quantify whole-body movements, providing novel bradykinesia indices for walking (WBI) and standing up from a chair (sit-to-stand; SBI). The proposed bradykinesia indices include the joint angles at both upper and lower limbs and trunk motion to compute a complete, objective score for whole body bradykinesia. Thirty PD and 11 age-matched healthy control participants were recruited for the study. The participants performed two standard walking tasks that involved multiple body joints in the upper and lower limbs. The WBI and SBI successfully identified differences between control and PD participants. The indices also effectively identified differences within the PD population, distinguishing participants assessed with (ON) and without (OFF) levodopa; the gold-standard of treatment for PD. The goal of this study is to provide health professionals with an objective score for whole body bradykinesia by simultaneously measuring the upper and lower extremities along with truncal movement. This method demonstrates potential to be used in conjunction with current clinical standards for motor symptom assessment, and may also be promising for the remote assessment of PD

  7. Whole-body protein turnover of a carnivore, Felis silvestris catus.

    Science.gov (United States)

    Russell, K; Lobley, G E; Millward, D J

    2003-01-01

    The cat (Felis silvestris catus) has a higher dietary protein requirement than omnivores and herbivores, thought to be due to metabolic inflexibility. An aspect of metabolic flexibility was examined with studies of whole-body protein turnover at two levels of dietary protein energy, moderate protein (MP; 20 %) and high protein (HP; 70 %), in five adult cats in a crossover design. Following a 14 d pre-feed period, a single intravenous dose of [15N]glycine was administered and cumulative excretion of the isotope in urine and faeces determined over 48 h. N flux increased (Pwork is required to determine exactly why cats have such a high protein requirement.

  8. Caffeine-induced hematological changes after whole-body irradiation in rat

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Kyu [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, Ji Hyang; Yoon Yong Dal [Hanyang University, Seoul (Korea, Republic of)

    2004-07-01

    Recent research indicated dietary antioxidants were useful radioprotectors to protect organisms against radiation-induced tissue lethality and other deleterious effects. Radioprotective effects of vitamin C have been demonstrated in certain cells and animals, which would result from scavenging free radicals. Moreover, the previous studies indicated that caffeine had been shown to potently act the radioprotector in irradiated mice. However it is not clear exactly about effects of caffeine treatments chronically after irradiation. So the present studies were designed to identify the hematological effect of caffeine treatments chronically one month after whole-body gamma irradiation.

  9. Variation in thickness of the large cryosections cut for whole-body autoradiography

    International Nuclear Information System (INIS)

    Ito, Tsunao; Brill, A.B.

    1991-01-01

    A method to assess variation in thickness of the large cryosections for whole-body autoradiography (WBARG) was described, and the degree of intraslice and interslice variations were determined for our cryomicrotome system (LKB PMV-2250). Intraslice variation in thickness of the 180 x 80 mm cryosection was 0.72-0.92 μm within the range of section thickness for WBARG (15-50 μm), and interslice variation was 0.89-1.21 μm. These potential variations in section thickness should be kept in mind whenever working with quantitative WBARG. (author)

  10. A 2-Tesla active shield magnet for whole body imaging and spectroscopy

    International Nuclear Information System (INIS)

    Davies, F.J.; Elliott, R.T.; Hawksworth, D.G.

    1991-01-01

    This paper reports on the development and testing of a 2T superconducting Active Shield magnet, with a 0.99m diameter warm bore for whole-body Magnetic Resonance Imaging (MRI) and spectroscopy. The magnet and cryostat were designed to meet the same performance standards as existing MRI magnets, but with the volume of the stray field region reduced to less than 4% of that for an unshielded magnet. The 0.5 mT stray field contour is within 5m axially and 3m radially of the magnet center. The system weight is only 14 tonnes

  11. Effect of Whole-Body Vibration on Speech. Part 2; Effect on Intelligibility

    Science.gov (United States)

    Begault, Durand R.

    2011-01-01

    The effect on speech intelligibility was measured for speech where talkers reading Diagnostic Rhyme Test material were exposed to 0.7 g whole body vibration to simulate space vehicle launch. Across all talkers, the effect of vibration was to degrade the percentage of correctly transcribed words from 83% to 74%. The magnitude of the effect of vibration on speech communication varies between individuals, for both talkers and listeners. A worst case scenario for intelligibility would be the most sensitive listener hearing the most sensitive talker; one participant s intelligibility was reduced by 26% (97% to 71%) for one of the talkers.

  12. Emergency treatment of exertional heatstroke and comparison of whole body cooling techniques.

    Science.gov (United States)

    Costrini, A

    1990-02-01

    This manuscript compares the whole body cooling techniques in the emergency treatment of heatstroke. Historically, the use of cold water immersion with skin massage has been quite successful in rapidly lowering body temperature and in avoiding severe complications or death. Recent studies have suggested alternative therapies, including the use of a warm air spray, the use of helicopter downdraft, and pharmacological agents. While evidence exists to support these methods, they have not been shown to reduce fatalities as effectively as ice water immersion. Although several cooling methods may have clinical use, all techniques rely on the prompt recognition of symptoms and immediate action in the field.

  13. Dry coupling for whole-body small-animal photoacoustic computed tomography

    Science.gov (United States)

    Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.

    2017-04-01

    We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.

  14. Development of 'Enhance reconstruction package' software for whole-body PET

    International Nuclear Information System (INIS)

    Mizuta, Tetsuro; Imanishi, Tatsuru; Ishikawa, Akihiro

    2011-01-01

    We have developed 'Enhance Reconstruction Package' Software for our whole-body positron emission tomography (PET) Eminence series. This package improves image quality and streamlines the workflow in clinical PET and PET/CT studies. The present paper describes an outline of the applications for data collection, normalization, etc. and also reports some PET images obtained by the software. The signal to noise ratio was optimized in the phantom study, leading to the improvement in image quality. The real time display tool and the remote control tool would make a contribution to enhancement in operability in the routine workflow. (author)

  15. Effect of whole-body irradiation on skeletal growth in rhesus monkeys

    International Nuclear Information System (INIS)

    Sonneveld, P.; van Bekkum, D.W.

    1979-01-01

    Late effects of single whole-body doses of 400 to 500 and 750 to 900 rads on skeletal growth in 32 rhesus monkeys were studied. Findings indicated growth inhibition strongly related to dose and age at irradiation. Doses of 750 to 900 rads before the age of 40 months resulted in significantly greater growth inhibition (11%) than doses given during or shortly after adolescence (p < 0.005). Doses of less than 750 rads were not significant. In view of the close similarity between monkeys and man, irradiation of children at doses greater than 750 rads may carry a strong risk of subsequent growth retardation

  16. Computer generated multi-color graphics in whole body gamma spectral analysis

    International Nuclear Information System (INIS)

    Phillips, W.G.; Curtis, S.P.; Environmental Protection Agency, Las Vegas, NV)

    1984-01-01

    A medium resolution color graphics terminal (512 x 512 pixels) was appended to a computerized gamma spectrometer for the display of whole body counting data. The color display enhances the ability of a spectroscopist to identify at a glance multicolored spectral regions of interest immediate qualitative interpretation. Spectral data from subjects containing low concentrations of gamma emitters obtained by both NaI(T1) and phoswich detectors are viewed by the method. In addition, software generates a multispectral display by which the gross, background, and net spectra are displayed in color simultaneously on a single screen

  17. Whole-body effective half-lives for radiolabeled antibodies and related issues

    Energy Technology Data Exchange (ETDEWEB)

    Kaurin, D.G.L.; Carsten, A.L.; Baum, J.W.; Barber, D.E.

    1996-08-01

    Radiolabeled antibodies (RABs) are being developed and used in medical imaging and therapy in rapidly increasing numbers. Data on the whole body half effective half-lives were calculated from external dose rates obtained from attending physicians and radiation safety officers at participating institutions. Calculations were made using exponential regression analysis of data from patients receiving single and multiple administrations. Theses data were analyzed on the basis of age, sex, isotope label, radiation energy, antibody type, disease treated, administration method, and number of administrations.

  18. Myeloid regeneration after whole body irradiation, autologous bone marrow transplantation, and treatment with an anabolic steroid

    International Nuclear Information System (INIS)

    Ambrus, C.M.; Ambrus, J.L.

    1975-01-01

    Stumptail monkeys (Macaca speciosa) received lethal whole-body radiation. Autologous bone marrow injection resulted in survival of the majority of the animals. Treatment with Deca-Durabolin, an anabolic steroid, caused more rapid recovery of colony-forming cell numbers in the bone marrow than in control animals. Both the Deca-Durabolin-treated and control groups were given autologous bone marrow transplantation. Anabolic steroid effect on transplanted bone marrow colony-forming cells may explain the increased rate of leukopoietic regeneration in anabolic steroid-treated animals as compared to controls

  19. Spontaneous and evoked cerebral activity modifications on whole-body γ irradiated adult rabbit

    International Nuclear Information System (INIS)

    Court, L.; Dufour, R.; Bassant, M.H.; Fatome, M.

    1976-01-01

    Whole-body γ-exposure from 150 to 850 rads (dose-rate: 14 rads.min -1 ) delivered to adult rabbits chronically implanted with electrodes resulted in prompt and delayed changes of behavior, arousal and spontaneous and evoked electrical activities. Electrophysiological techniques of polygraphic recording and signal processing showed that the alterations were related to the absorbed dose. The threshold dose accompanied with transient changes of arousal should be in the range of 50-100 rads; below this range, to the exclusion of some possible behavior changes, exposure should act as a stimulation that would become nociceptive at higher doses only [fr

  20. Dependence of a whole body counting efficiency on body size and composition

    International Nuclear Information System (INIS)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R.

    2001-01-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  1. Dependence of a whole body counting efficiency on body size and composition

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2001-07-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  2. 24-hour whole-body retention of sup(99m)Tc-diphosphonate

    International Nuclear Information System (INIS)

    Kapitola, J.

    1985-01-01

    A new method is described for the examination of bone tissue metabolism; a 24-hour retention of diphosphonate labelled with radioactive sup(99m)Tc (assessed using a whole-body counter or by estimation of the amount of labelled substance excreted in the course of 24 hours via the urine). The values are elevated in primary hyperparathyroidism, osteomalacia, generalized Paget's disease, multiple bone metastases; the values are not uniform in osteoporosis. The method is simple, sensitive and reliable (provided renal function is normal), suited for screening, as part of specialized osteological diagnosis as well as for repeated longitudinal investigations. (author)

  3. Parasympathetic activity and blood catecholamine responses following a single partial-body cryostimulation and a whole-body cryostimulation.

    Directory of Open Access Journals (Sweden)

    Christophe Hausswirth

    Full Text Available The aim of this study was to compare the effects of a single whole-body cryostimulation (WBC and a partial-body cryostimulation (PBC (i.e., not exposing the head to cold on indices of parasympathetic activity and blood catecholamines. Two groups of 15 participants were assigned either to a 3-min WBC or PBC session, while 10 participants constituted a control group (CON not receiving any cryostimulation. Changes in thermal, physiological and subjective variables were recorded before and during the 20-min after each cryostimulation. According to a qualitative statistical analysis, an almost certain decrease in skin temperature was reported for all body regions immediately after the WBC (mean decrease±90% CL, -13.7±0.7°C and PBC (-8.3±0.3°C, which persisted up to 20-min after the session. The tympanic temperature almost certainly decreased only after the WBC session (-0.32±0.04°C. Systolic and diastolic blood pressures were very likely increased after the WBC session, whereas these changes were trivial in the other groups. In addition, heart rate almost certainly decreased after PBC (-10.9% and WBC (-15.2% sessions, in a likely greater proportion for WBC compared to PBC. Resting vagal-related heart rate variability indices (the root-mean square difference of successive normal R-R intervals, RMSSD, and high frequency band, HF were very likely increased after PBC (RMSSD: +54.4%, HF: +138% and WBC (RMSSD: +85.2%, HF: +632% sessions without any marked difference between groups. Plasma norepinephrine concentrations were likely to very likely increased after PBC (+57.4% and WBC (+76.2%, respectively. Finally, cold and comfort sensations were almost certainly altered after WBC and PBC, sensation of discomfort being likely more pronounced after WBC than PBC. Both acute cryostimulation techniques effectively stimulated the autonomic nervous system (ANS, with a predominance of parasympathetic tone activation. The results of this study also suggest

  4. Effect of Film Dressing on Acute Radiation Dermatitis Secondary to Proton Beam Therapy

    International Nuclear Information System (INIS)

    Arimura, Takeshi; Ogino, Takashi; Yoshiura, Takashi; Toi, Yuya; Kawabata, Michiko; Chuman, Ikuko; Wada, Kiyotaka; Kondo, Naoaki; Nagayama, Shinichi; Hishikawa, Yoshio

    2016-01-01

    Purpose: Acute radiation dermatitis (ARD) is one of the most common adverse events of proton beam therapy (PBT), and there is currently no effective method to manage ARD. The purpose of this study was to examine the prophylactic effect of a film dressing using Airwall on PBT-induced ARD compared with standard skin managements. Methods and Materials: A total of 271 patients with prostate cancer who were scheduled for PBT at our center were divided into 2 groups based on their own requests: 145 patients (53%) chose Airwall (group A) and 126 patients (47%) received standard treatments (group B). We evaluated irradiated skin every other day during PBT and followed up once a week for a month after completion of PBT. Results: Grade 0, 1, 2, and 3 dermatitis were seen in 2, 122, 21, and 0 and 0, 65, 57, and 4 patients in groups A and B, respectively (P<.001). Numbers of days to grades 1 and 2 ARD development were 34.9 ± 14.3 and 54.7 ± 10.3 and 31.8 ± 11.3 and 54.4 ± 11.6 in groups A and B, respectively. There were no significant differences between the 2 groups. Eighteen patients (12%) in group A who experienced problems in the region covered with Airwall switched to standard skin care after peeling the film off. Conclusions: Film dressing using Airwall reduced the severity of ARD without delaying the response time of the skin to proton beam irradiation compared with standard skin management. Hence, film dressing is considered a promising measure for preventing ARD secondary to PBT.

  5. Effect of Film Dressing on Acute Radiation Dermatitis Secondary to Proton Beam Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Arimura, Takeshi, E-mail: arimura-takeshi@medipolis.org [Medipolis Proton Therapy and Research Center, Ibusuki (Japan); Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima (Japan); Ogino, Takashi [Medipolis Proton Therapy and Research Center, Ibusuki (Japan); Yoshiura, Takashi [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima (Japan); Toi, Yuya; Kawabata, Michiko; Chuman, Ikuko; Wada, Kiyotaka; Kondo, Naoaki; Nagayama, Shinichi; Hishikawa, Yoshio [Medipolis Proton Therapy and Research Center, Ibusuki (Japan)

    2016-05-01

    Purpose: Acute radiation dermatitis (ARD) is one of the most common adverse events of proton beam therapy (PBT), and there is currently no effective method to manage ARD. The purpose of this study was to examine the prophylactic effect of a film dressing using Airwall on PBT-induced ARD compared with standard skin managements. Methods and Materials: A total of 271 patients with prostate cancer who were scheduled for PBT at our center were divided into 2 groups based on their own requests: 145 patients (53%) chose Airwall (group A) and 126 patients (47%) received standard treatments (group B). We evaluated irradiated skin every other day during PBT and followed up once a week for a month after completion of PBT. Results: Grade 0, 1, 2, and 3 dermatitis were seen in 2, 122, 21, and 0 and 0, 65, 57, and 4 patients in groups A and B, respectively (P<.001). Numbers of days to grades 1 and 2 ARD development were 34.9 ± 14.3 and 54.7 ± 10.3 and 31.8 ± 11.3 and 54.4 ± 11.6 in groups A and B, respectively. There were no significant differences between the 2 groups. Eighteen patients (12%) in group A who experienced problems in the region covered with Airwall switched to standard skin care after peeling the film off. Conclusions: Film dressing using Airwall reduced the severity of ARD without delaying the response time of the skin to proton beam irradiation compared with standard skin management. Hence, film dressing is considered a promising measure for preventing ARD secondary to PBT.

  6. Whole-body magnetic resonance angiography of patients using a standard clinical scanner

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Tomas; Wikstroem, Johan; Eriksson, Mats-Ola; Lundberg, Anders; Ahlstroem, Haakan [Uppsala University Hospital, Department of Diagnostic Radiology, Uppsala (Sweden); Johansson, Lars [Uppsala University Hospital, Uppsala (Sweden); Ljungman, Christer [Uppsala University Hospital, Department of Vascular Surgery, Uppsala (Sweden); Hoogeven, Romhild [Philips Medical Systems, MR Clinical Science, Best (Netherlands)

    2006-01-01

    The purpose of this study was to evaluate the technique of whole-body magnetic resonance angiography (MRA) of patients with a standard clinical scanner. Thirty-three patients referred for stenoses, occlusions, aneurysms, assessment of patency of vascular grafts, vasculitis and vascular aplasia were examined in a 1.5-T scanner using its standard body coil. Three-dimensional sequences were acquired in four stations after administration of one intravenous injection of 40 ml conventional gadolinium contrast agent. Different vessel segments were evaluated as either diagnostic or nondiagnostic and regarding the presence of stenoses with more than 50% diameter reduction, occlusions or aneurysms. Of 923 vessel segments, 67 were not evaluable because of poor contrast filling (n=31), motion artefacts (n=20), venous overlap (n=12) and other reasons (n=4). Stenoses of more than 50%, occlusions or aneurysms were observed in 26 patients (129 segments). In nine patients additional unsuspected pathology was found. In 10 out of 14 patients (71/79 segments) there was conformity between MRA and digital subtraction angiography regarding the grade of stenosis. This study shows that whole-body MRA with a standard clinical scanner is feasible. Motion artefacts and the timing of the contrast agent through the different segments are still problems to be solved. (orig.)

  7. Enhancement of committed hematopoietic stem cell colony formation by nandrolone decanoate after sublethal whole body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gallicchio, V.S.; Chen, M.G.; Watts, T.D.

    1984-11-01

    The ability of an anabolic steroid, nandrolone decanoate, to increase committed topoietic stem cell (CFU-gm, CFU-e, and BFU-e) colony formation after sublethal irradiation was evaluated. Immediately after receiving whole body irradiation and on the next two days, each mouse was injected intraperitoneally with nandrolone decanoate (1.25 mg) in propylene glycol. Irradiated control mice received only propylene glycol. Compared to controls, drug-treated mice showed marked peripheral blood leukocytosis and more stable packed red cell volume. Drug-treated mice also demonstrated increased erythropoiesis, as CFU-e/BFU-e concentrations from both marrow (9% to 581%) and spleen (15% to 797%) were elevated. Granulopoiesis was increased similarly, as CFU-gm concentrations from marrow (38% to 685%) and spleen (9% to 373%) were elevated. These results demonstrate that nandrolone decanoate enhances hematopoietic stem cell recovery after sublethal whole body irradiation. This suggests that following hematopoietic suppression, nandrolone decanoate may stimulate the recovery of hematopoiesis at the stem cell level and in peripheral blood.

  8. Estimation of throium deposited in thorotrast patients by whole body counter

    International Nuclear Information System (INIS)

    Tatsumi-Miyajima, Junko; Okajima, Shunzo; Takao, Hideaki; Norimura, Toshiyuki.

    1986-01-01

    Thorotrast, a colloidal solution of thorium dioxide was injected to wounded soldiers, for angiography from 1930 to 1945. The patients who received Thorotrast are interesting objects for finding a biological effect due to the internal irradiation by 232 Th. To determine a distribution and body burden of 232 Th, forty-one Thorotrast patients were measured their gamma-rays with a pair of NaI(T1) scintillation detectors coaxially positioned above and below the coach in the whole body counter of Nagasaki University. The comparison between the usual method using constant values and the method using individual values depend on the organ positions determined with CT (Computed Tomography) scanner for patients was performed to estimate the errors due to the individual differences in the detection efficiency of 232 Th. From the results, the estimates by the whole body counter of the amounts of 232 Th deposits in abdominal region were obtained within the uncertainties of 16 %. And the absorbed dose in the liver and the spleen was also estimated from the amounts of 232 Th. (author)

  9. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  10. Detection of Recurrent Cervical Cancer by Whole-body FDG PET Scans

    Institute of Scientific and Technical Information of China (English)

    Jiaxin Yang; Jinhui Wang; Zhaohui Zhu; Keng Shen; Bocheng Wang

    2008-01-01

    OBJECTIVE To evaluate the role of whole-body {18F} fluro-2-dexoxyglucose (FDG) positron emission tomography (PET) scans in the detection of recurrent cervical cancer.METHODS Between June, 2000 and January, 2006, 25 patients had undergone a PET scan at the Peking Union Medical College Hospital to evaluate possible recurrent cervical cancer. All the PET findings were reviewed and compared to available clinical data to classify each PET scan result as a true positive, true negative, false positive, or false negative.RESULTS A total of 38 PET scans were conducted on the 25patients whose median age was 46 years. The Stage distributions were IA (n = 1), IB (n = 11), IIA (n = 5), IIB (n = 4), IIIB (n = 2), WB (n= 1), and unknown Stage (n = 1). There were 22 cases of squamous cell carcinoma and 3 cases of adenocarcinoma resulting in 9 true positive PET scans, 27 true negatives, 2 false positives and no false negatives. The sensitivity of the FDG PET scans for detecting recurrent cervical cancer was 100%, specificity 93.1%, positive predictive value 81.8%, and negative predictive value 100%.CONCLUSION The whole body FDG PET scans are a sensitive and specific imaging modality for the detection of recurrent cervical cancer. However the cost of PET scans is too high at this time. A large prospective study will determine whether this modality should be used routinely and take the place of other imaging methods in the early detection of recurrent cervical carcinoma

  11. Lightweight Vehicle and Driver’s Whole-Body Models for Vibration Analysis

    Science.gov (United States)

    MdSah, Jamali; Taha, Zahari; Azwan Ismail, Khairul

    2018-03-01

    Vehicle vibration is a main factor for driving fatigue, discomfort and health problems. The ability to simulate the vibration characteristics in the vehicle and its effects on driver’s whole-body vibration will give significant advantages to designers especially on the vehicle development time and cost. However, it is difficult to achieve optimal condition of ride comfort and handling when using passive suspension system. This paper presents mathematical equations that can be used to describe the vibration characteristics of a lightweight electric vehicle that had been developed. The vehicle’s model was combined with the lumped-parameter model of driver to determine the whole-body vibration level when the vehicle is passing over a road hump using Matlab Simulink. The models were simulated at a constant speed and the results were compared with the experimental data. The simulated vibration level at the vehicle floor and seat were almost similar to the experimental vibration results. The suspension systems that are being used for the solar vehicle are able to reduce the vibration level due to the road hump. The models can be used to simulate and choose the optimal parameters for the suspensions.

  12. Calcium metabolism in fluorosis and endemic genu valgum using radioactive tracer, whole body counting and radioimmunoassay

    International Nuclear Information System (INIS)

    Narasinga Rao, B.

    1979-11-01

    Endemic fluorosis with extensive skeletal changes has been reported from several parts of India. In recent years a new condition, endemic genu valgum, has been recognized in one of these areas. In both conditions osteosclerosis, particularly of the spine, has been observed, but in genu valgum the most distinctive pathology is osteoporosis in bones of the extremities and presumably as a result the ''knock knees'' that give the syndrome its name. In this project certain aspects of calcium metabolism were investigated in endemic fluorosis and genu valgum and in appropriate control subjects. Calcium kinetics were studied by intravenously injecting a tracer dose of 47 Ca and following for 10 days thereafter the concentration of the tracer in serum and excreta, as well as its total retention in the body (the latter measured by whole body counting). In addition calcium balance was measured on some of the subjects while resident in a metabolic ward. Statistical analysis of the results showed in general a higher metabolic activity of calcium in the fluorosis and genu valgum cases than in the controls (specifically, higher ''turnover'' of calcium in the blood pool and an apparently elevated bone mineralization rate). Whole body retention was somewhat greater in the patients than in the controls. Several measurements were also performed relative to blood chemistry, and in particular the serum concentration of 25-OHD 3 (a metabolite of vitamin D) was measured. There was no evidence that vitamin D deficiency played a significant role in the causation of genu valgum

  13. Between-country comparison of whole-body SAR from personal exposure data in Urban areas.

    Science.gov (United States)

    Joseph, Wout; Frei, Patrizia; Röösli, Martin; Vermeeren, Günter; Bolte, John; Thuróczy, György; Gajšek, Peter; Trček, Tomaž; Mohler, Evelyn; Juhász, Péter; Finta, Viktoria; Martens, Luc

    2012-12-01

    In five countries (Belgium, Switzerland, Slovenia, Hungary, and the Netherlands), personal radio frequency electromagnetic field measurements were performed in different microenvironments such as homes, public transports, or outdoors using the same exposure meters. From the mean personal field exposure levels (excluding mobile phone exposure), whole-body absorption values in a 1-year-old child and adult male model were calculated using a statistical multipath exposure method and compared for the five countries. All mean absorptions (maximal total absorption of 3.4 µW/kg for the child and 1.8 µW/kg for the adult) were well below the International Commission on Non-Ionizing Radiation Protection (ICNIRP) basic restriction of 0.08 W/kg for the general public. Generally, incident field exposure levels were well correlated with whole-body absorptions (SAR(wb) ), although the type of microenvironment, frequency of the signals, and dimensions of the considered phantom modify the relationship between these exposure measures. Exposure to the television and Digital Audio Broadcasting band caused relatively higher SAR(wb) values (up to 65%) for the 1-year-old child than signals at higher frequencies due to the body size-dependent absorption rates. Frequency Modulation (FM) caused relatively higher absorptions (up to 80%) in the adult male. Copyright © 2012 Wiley Periodicals, Inc.

  14. Whole-body vibration versus proprioceptive training on postural control in post-menopausal osteopenic women.

    Science.gov (United States)

    Stolzenberg, Nils; Belavý, Daniel L; Rawer, Rainer; Felsenberg, Dieter

    2013-07-01

    To prevent falls in the elderly, especially those with low bone density, is it necessary to maintain muscle coordination and balance. The aim of this study was to examine the effect of classical balance training (BAL) and whole-body vibration training (VIB) on postural control in post-menopausal women with low bone density. Sixty-eight subjects began the study and 57 completed the nine-month intervention program. All subjects performed resistive exercise and were randomized to either the BAL- (N=31) or VIB-group (N=26). The BAL-group performed progressive balance and coordination training and the VIB-group underwent, in total, four minutes of vibration (depending on exercise; 24-26Hz and 4-8mm range) on the Galileo Fitness. Every month, the performance of a single leg stance task on a standard unstable surface (Posturomed) was tested. At baseline and end of the study only, single leg stance, Romberg-stance, semi-tandem-stance and tandem-stance were tested on a ground reaction force platform (Leonardo). The velocity of movement on the Posturomed improved by 28.3 (36.1%) (ppostural control in post-menopausal women with low bone density. The current study could not provide evidence for a significantly different impact of whole-body vibration or balance training on postural control. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Whole body bone scintigram with sup(99m)Tc-phosphate compounds

    International Nuclear Information System (INIS)

    Oyamada, Hiyoshimaru; Orii, Hirotake; Tabei, Toshio; Ishibashi, Hiroyoshi.

    1975-01-01

    Among the compounds of four different types, which are sup(99m)Tc-polyphosphate suppled by A Company, sup(99m)Tc-pyrophosphate by B Company, and sup(99m)Tc-pyrophosphate of electrolysis method and sup(99m)Tc-diphosphonate by C Company, sup(99m)Tc-diphosphonate showed the most favorable result with a constantly good scintigram quality. The remaining three compounds were found also favorable for clinical application. Besides these are undesirable accumulations, rather low energy of sup(99m)Tc-causes different pictures upon the anterior and the posterior views, and previously irradiated area shows a decreased uptake of these compounds. The usefulness of whole body scintigrams in the detection of metastatic bone tumors was also discussed. There was a definite superiority with this technique over the conventional X-ray study. Especially, in thoracic vertebrae, pelvic bone, and ribs, far many diseased areas were detected on the scintigrams than the areas which the physicians noticed or suspected the metastases. As a conclusion, although there are some problems on the scintigrams, it can be said that sup(99m)Tc-phosphate compounds are very useful in detection of metastatic bone tumors, especially with the help of whole body scanner. (JPN)

  16. Whole-body profile scanner for in vivo quantitative activity measurement

    International Nuclear Information System (INIS)

    Bergmann, H.

    1978-01-01

    A whole-body profile scanner has been developed by fitting parallel slit collimators to a shadow shield whole-body counter. Sensitivity, uniformity and resolution measurements were performed using a number of different counting conditions. It is shown that improved accuracy of activity measurements is obtained by using a wide window counting technique for low and medium energy gamma emitters (99m Tc, 131 I), whereas a photopeak window should be used for high energy gamma emitters (47 Ca). Due to the finite spatial resolution of the system a systematic error in evaluating regional activities from the counting rate profile occurs which is characterized by a spatial spillover factor. The spatial spillover factor is measured and is subsequently used to calculate the error on basis of a simple model. It is shown that only small errors are caused by spatial spillover when the length of a region is at least three times the full width half maximum of the point spread function. Applying the above mentioned simple rules it is concluded that profile scanning is a sensitive and accurate technique for activity measurements in vivo. Two examples of clinical applications (measurement of bone accretion rates of calcium and Tc-pyrophosphate, regional radioiodine retention in patients with thyroid carcinoma) and a review of the papers on profile scanning demonstrate the types of investigations in which profile scanning is superior to alternative techniques. (author)

  17. Hilar activity on the F-18 FDG whole-body PET studies

    International Nuclear Information System (INIS)

    Fujii, Hirofumi; Kitamura, Masayuki; Kubo, Atsushi; Yasuda, Seiei; Ide, Michiru; Takahashi, Wakoh; Shohtsu, Akira

    1999-01-01

    We evaluated the clinical characteristics of hilar activity that would be false positive findings for cancer screening on whole-body FDG PET. The cases with increased hilar activity were selected from 1,126 cases who received whole-body FDG PET between September 1996 and August 1997, and their age, sex, complication of inflammatory process in lungs, numbers of visualized mediastinal lymph nodes, frequency of smoking, blood sugar level and concentration of HbA1c were studied. FDG accumulation in the hilar regions was found in 63 cases (5.6%). The cases with increased hilar activity were older, a higher incidence of complication of pulmonary inflammation, a larger number of visualized mediastinal lymph nodes and were more frequent smokers than the control cases with normal FDG distribution. Their male-to-female ratio, blood sugar level and concentration of HbA1c were not significantly different from those of the control cases. These results suggested that an inflammatory process around the hilar region might induce this confusing FDG accumulation. (author)

  18. Whole-body vibration improves cognitive functions of an adult with ADHD.

    Science.gov (United States)

    Fuermaier, Anselm B M; Tucha, Lara; Koerts, Janneke; van den Bos, Meinris; Regterschot, G Ruben H; Zeinstra, Edzard B; van Heuvelen, Marieke J G; van der Zee, Eddy A; Lange, Klaus W; Tucha, Oliver

    2014-09-01

    Adult attention deficit hyperactivity disorder (ADHD) is associated with a variety of cognitive impairments, which were shown to affect academic achievement and quality of life. Current treatment strategies, such as stimulant drug treatment, were demonstrated to effectively improve cognitive functions of patients with ADHD. However, most treatment strategies are associated with a number of disadvantages in a considerable proportion of patients, such as unsatisfactory effects, adverse clinical side effects or high financial costs. In order to address limitations of current treatment strategies, whole-body vibration (WBV) might represent a novel approach to treat cognitive dysfunctions of patients with ADHD. WBV refers to the exposure of the whole body of an individual to vibration and was found to affect physiology and cognition. In the present study, WBV was applied on 10 consecutive days to an adult diagnosed with ADHD. Neuropsychological assessments were performed repeatedly at three different times, i.e., the day before the start of the treatment, on the day following completion of treatment and 14 days after the treatment have been completed (follow-up). An improved neuropsychological test performance following WBV treatment points to the high clinical value of WBV in treating patients with neuropsychological impairments such as ADHD.

  19. Distribution of /sup 63/Ni in mice by means of whole body autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Saito, T [Nihon Univ., Tokyo. School of Dentistry

    1974-11-01

    The uptake of Ni which was known to be contained in the dental alloy to the mammalian tissue was studied. /sup 63/Ni was injected intravenously to mice, and its distribution in their body was observed by counting radioactivity using whole body autoradiography and liquid scintillation counter from 30 minutes after the injection to 3 weeks later. Whole body autography revealed high uptake in the kidney, lung, incisor, intervertebral disc, epidermis cuticle, hair follicle, and liver during 30 minutes later to 8 hours period, and in the lung, renal cortex, central nerve, epidermis cuticle, and hair follicle during 2 days to 3 weeks period. /sup 63/Ni taken up in the tissue or organs rapidly disappeared by 8 hours period, and the rank of high uptake tissues slightly changed during 30 minutes later to 8 hours period. /sup 63/Ni administered in the body was considered to be excreted through the kidney, however, /sup 63/Ni taken up in the central nerve showed remarkably delayed excretion.

  20. Kidney, lower limb and whole-body uptake and release of catecholamines in alcoholic liver disease

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Ring-Larsen, H; Christensen, N J

    1988-01-01

    Regional (kidney, lower limb) and whole-body kinetics of endogenous noradrenaline (NA) and tritium-labelled L-noradrenaline (3H-NA) were determined in patients with alcoholic liver disease (one alcoholic hepatitis, 12 cirrhosis) and in control subjects (n = 6) in order to get information...... (0.69 vs. 0.45 pmol/min.g per pmol/min.g in controls, P less than 0.005) but not in the lower limb (0.23 vs. 0.49 in controls, P less than 0.01). In patients with ascites the spillover rate of NA from the kidney into plasma (1.9 pmol/min.g) was significantly increased (P less than 0.02) compared...... to controls and non-ascitic patients (1.2 and 1.0 pmol/min.g, respectively. Patients and control kidneys and limbs extracted almost the same fraction of 3H-NA (0.34 vs. 0.32 NS and 0.34 vs. 0.37 NS, respectively). Whole-body clearance of 3H-NA was not significantly different in cirrhotics and controls (median...

  1. Experimental study of absorption of iron in foods using whole-body counter

    International Nuclear Information System (INIS)

    Nakamura, Tadamitsu

    1978-01-01

    Male rats of Wistar strain which showed normal hematological picture were given 59 Fe-labeled foods orally, and the iron absorption rate was determined by an animal whole body counter. When 59 Fe was given in a mixture with each of gruel, spinach, cow's milk, the yolk, and the yolk with orange juice, the iron absorption rates in each food were 9.4%, 8.9%, 6.6%, 10.8% and 7.2% respectively. None of these foods seemed to inhibit the 59 Fe absorption. When 59 Fe was given in a mixture with chicken, the iron absorption rate was 35.8%. This result suggested that the chicken promoted the 59 Fe absorption. When the yolk labeled in vivo with 59 Fe was given, the iron absorption rate was 4.9%. If the yolk labeled in vitro was used, the absorption rate was 10.8%. When the yolk labeled in vivo with 59 Fe was given with orange juice, the iron absorption rate was 13.3%. If the yolk labeled in vivo with 59 Fe was given, the absorption rate was 7.2%. Orange juice had no effect on the iron absorption when the yolk labeled in vitro was used. After chicken eggs labeled in vivo with 59 Fe was given to children, the iron absorption was determined by a whole body counter; the rate averaged 5.4 in the children without anemia and 24.7 in those with anemia. (Ueda, J.)

  2. Muscle MRI / whole-body MRI in diagnosis and dynamic evaluation of neuro-muscular disorders

    Directory of Open Access Journals (Sweden)

    Robert Carlier

    2014-01-01

    Full Text Available The use of MRI in myopathies dates back to more than 20 years. The first investigations were slow and only allowed segmental and limited studies. Whole-body MRI has emerged over the past twelve years and became a useful diagnostic tool in the etiological diagnosis of myopathies and muscular dystrophies. This study must always be confronted with clinical and whichever other paraclinical data without being able to replace them. Indications to perform such an investigation are getting better and better defined and the diagnostic efficacy has progressed with the increasing number of cases, communications, publications and discussions within multidisciplinary working groups. Its noninvasive nature, the radiation-free exposure and its reasonable cost also enable this technique to be easily accepted by the patient. It also provides a valuable tool for monitoring the natural disease progression or the effectiveness of therapies. The radiology team must be acquainted with the management of neuromuscular patients. Interpreting muscle whole-body MRI requires an excellent knowledge of muscle anatomy whichever body part is examined. The radiologist performing these studies is ideally a specialist of musculoskeletal disorders or a neuroradiologist well trained in muscle anatomy.

  3. Hematological Profile and Martial Status in Rugby Players during Whole Body Cryostimulation

    Science.gov (United States)

    Lombardi, Giovanni; Lanteri, Patrizia; Porcelli, Simone; Mauri, Clara; Colombini, Alessandra; Grasso, Dalila; Zani, Viviana; Bonomi, Felice Giulio; Melegati, Gianluca; Banfi, Giuseppe

    2013-01-01

    Cold-based therapies are commonly applied to alleviate pain symptoms secondary to inflammatory diseases, but also to treat injuries or overuse, as done in sports rehabilitation. Whole body cryotherapy, a relatively new form of cold therapy, consists of short whole-body exposure to extremely cold air (−110°C to −140°C). Cryostimulation is gaining wider acceptance as an effective part of physical therapy to accelerate muscle recovery in rugby players. The aim of this study was to evaluate the effect of repeated cryostimulation sessions on the hematological profile and martial status markers in professional rugby players. Twenty-seven professional rugby players received 2 daily cryostimulation treatments for 7 consecutive days. Blood samples were collected before and after administration of the cryotherapic protocol and hematological profiles were obtained. No changes in the leukocyte count or composition were seen. There was a decrease in the values for erythrocytes, hematocrit, hemoglobin and mean corpuscular hemoglobin content, and an increase in mean corpuscular volume and red cell distribution width. Platelet count and mean volume remained unchanged. Serum transferrin and ferritin decreased, while soluble transferrin receptor increased. Serum iron and transferrin saturation were unchanged, as was reticulocyte count, whereas the immature reticulocyte fraction decreased substantially. In conclusion, in this sample of professional rugby players, cryostimulation modified the hematological profile, with a reduction in erythrocyte count and hemoglobinization paralleled by a change in martial status markers. PMID:23383348

  4. Whole-body Cryotherapy as a Recovery Technique after Exercise: A Review of the Literature.

    Science.gov (United States)

    Rose, Catriona; Edwards, Kate M; Siegler, Jason; Graham, Kenneth; Caillaud, Corinne

    2017-12-01

    This review aims to evaluate the current body of literature investigating the effect of whole body cryotherapy on recovery after exercise. A systematic search was conducted to investigate the effect of whole body cryotherapy (WBC, exposure to temperatures between -110 to -190°C) on markers of recovery after damaging exercise in healthy, physically active subjects. Of the 16 eligible articles extracted, ten induced muscle damage using controlled exercise in a laboratory setting, while six induced damage during sport-specific training. Results indicated that muscle pain was reduced in 80% of studies following WBC. Two applied studies found recovery of athletic capacity and performance with WBC improved, variables of this nature were also improved in 71% of studies using controlled exercise. Further benefits of WBC treatment included reduction of systemic inflammation and lower concentrations of markers for muscle cell damage. These results suggest that WBC may improve recovery from muscle damage, with multiple exposures more consistently exhibiting improvements in recovery from pain, loss of muscle function, and markers of inflammation and damage. The diversity in muscle damage protocols, exposure timing with regards to exercise, as well as temperatures, duration and frequencies of exposure, make specific recommendations preliminary at present. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics

    International Nuclear Information System (INIS)

    Maroy, R.; Boisgard, R.; Comtat, C.; Dolle, F.; Trebossen, R.; Tavitian, B.; Frouin, V.; Cathier, P.; Duchesnay, E.; D; Nielsen, P.E.

    2008-01-01

    Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmentation of rodent whole-body PET images that takes these two difficulties into account by estimating the pharmacokinetics far from organ borders. The segmentation method proved efficient on whole-body numerical rat phantom simulations, including 3-14 organs, together with physiological movements (heart beating, breathing, and bladder filling). The method was resistant to spillover and physiological movements, while other methods failed to obtain a correct segmentation. The radioactivity concentrations calculated with this method also showed an excellent correlation with the manual delineation of organs in a large set of preclinical images. In addition, it was faster, detected more organs, and extracted organs' mean time activity curves with a better confidence on the measure than manual delineation. (authors)

  6. Typical whole body vibration exposure magnitudes encountered in the open pit mining industry.

    Science.gov (United States)

    Howard, Bryan; Sesek, Richard; Bloswick, Don

    2009-01-01

    According to recent research, a causal link has been established between occupational exposure to whole body vibration and an increased occurrence of low back pain. To aid in the further development of an in-house health and safety program for a large open pit mining facility interested in reducing back pain among its operators, whole body vibration magnitudes were characterized for a range of jobs. Specifically, thirty-five individual jobs from five different areas across the facility were evaluated for tri-axial acceleration levels during normal operating conditions. Tri-axial acceleration magnitudes were categorized into thirteen job groups. Job groups were ranked according to exposure and compared to the ISO 2631-1 standard for health risk assessment. Three of the thirteen job groups produced tri-axial acceleration magnitudes below the ISO 2631-1 low/moderate health caution limit for a twelve hour exposure. Six of the thirteen job groups produced exposures within the moderate health risk range. Four job groups were found to subject operators to WBV acceleration magnitudes above the moderate/high health caution limit.

  7. Computational modeling of blast induced whole-body injury: a review.

    Science.gov (United States)

    Chanda, Arnab; Callaway, Christian

    2018-02-01

    Blast injuries affect millions of lives across the globe due to its traumatic after effects on the brain and the whole body. To date, military grade armour materials are designed to mitigate ballistic and shrapnel attacks but are less effective in resisting blast impacts. In order to improve blast absorption characteristics of armours, the first key step is thoroughly understands the effects of blasts on the human body itself. In the last decade, a plethora of experimental and computational work has been carried out to investigate the mechanics and pathophysiology of Traumatic Brain Injury (TBI). However, very few attempts have been made so far to study the effect of blasts on the various other parts of the body such as the sensory organs (eyes and ears), nervous system, thorax, extremities, internal organs (such as the lungs) and the skeletal system. While an experimental evaluation of blast effects on such physiological systems is difficult, developing finite element (FE) models could allow the recreation of realistic blast scenarios on full scale human models and simulate the effects. The current article reviews the state-of-the-art in computational research in blast induced whole-body injury modelling, which would not only help in identifying the areas in which further research is required, but would also be indispensable for understanding body location specific armour design criteria for improved blast injury mitigation.

  8. Whole body and forearm substrate metabolism in hyperthyroidism: evidence of increased basal muscle protein breakdown.

    Science.gov (United States)

    Riis, Anne Lene Dalkjaer; Jørgensen, Jens Otto Lunde; Gjedde, Signe; Nørrelund, Helene; Jurik, Anne Grethe; Nair, K S; Ivarsen, Per; Weeke, Jørgen; Møller, Niels

    2005-06-01

    Thyroid hormones have significant metabolic effects, and muscle wasting and weakness are prominent clinical features of chronic hyperthyroidism. To assess the underlying mechanisms, we examined seven hyperthyroid women with Graves' disease before (Ht) and after (Eut) medical treatment and seven control subjects (Ctr). All subjects underwent a 3-h study in the postabsorptive state. After regional catheterization, protein dynamics of the whole body and of the forearm muscles were measured by amino acid tracer dilution technique using [15N]phenylalanine and [2H4]tyrosine. Before treatment, triiodothyronine was elevated (6.6 nmol/l) and whole body protein breakdown was increased 40%. The net forearm release of phenylalanine was increased in hyperthyroidism (microg.100 ml(-1).min(-1)): -7.0 +/- 1.2 Ht vs. -3.8 +/- 0.8 Eut (P = 0.04), -4.2 +/- 0.3 Ctr (P = 0.048). Muscle protein breakdown, assessed by phenylalanine rate of appearance, was increased (microg.100 ml(-1).min(-1)): 15.5 +/- 2.0 Ht vs. 9.6 +/- 1.4 Eut (P = 0.03), 9.9 +/- 0.6 Ctr (P = 0.02). Muscle protein synthesis rate did not differ significantly. Muscle mass and muscle function were decreased 10-20% before treatment. All abnormalities were normalized after therapy. In conclusion, our results show that hyperthyroidism is associated with increased muscle amino acid release resulting from increased muscle protein breakdown. These abnormalities can explain the clinical manifestations of sarcopenia and myopathy.

  9. Whole-body MRI in adult inflammatory myopathies: Do we need imaging of the trunk?

    International Nuclear Information System (INIS)

    Filli, Lukas; Manoliu, Andrei; Andreisek, Gustav; Guggenberger, Roman; Maurer, Britta

    2015-01-01

    To evaluate whether imaging of the trunk could be omitted in patients with inflammatory myopathies without losing diagnostic accuracy using a restricted whole-body magnetic resonance imaging (rWB-MRI) protocol. After approval by the institutional review board, this study was performed in 63 patients (male/female, 13/50; median age, 52 years; range, 20-81 years) with new-onset myopathic symptoms (group 1, n = 41) or previously diagnosed inflammatory myopathy (group 2, n = 22). After performing whole-body MRI (WB-MRI) at 3.0 Tesla, myositis and fatty atrophy were evaluated in different muscles by two independent radiologists. The intra-class correlation coefficient (ICC) was calculated to evaluate inter-observer reliability. Acquisition time was 56:01 minutes for WB-MRI and 37:37 minutes (32.8 % shorter) for rWB-MRI. In group 1, 14 patients were diagnosed with inflammatory myopathy based on muscle biopsy. rWB-MRI and WB-MRI showed equal sensitivity (42.9 %) and specificity (100 %) for myositis, and showed equal sensitivity (71.4 %) and similar specificity (63.0 % and 48.1 %, respectively) for fatty atrophy. No myositis was found in the body trunk in any patient. Inter-observer reliability was between substantial and perfect (ICC, 0.77-1.00). rWB-MRI showed diagnostic accuracy similar to WB-MRI for inflammatory myopathy at markedly reduced overall acquisition time. (orig.)

  10. Whole-body MRI in adult inflammatory myopathies: Do we need imaging of the trunk?

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Manoliu, Andrei; Andreisek, Gustav; Guggenberger, Roman [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Maurer, Britta [University Hospital Zurich, University of Zurich, Division of Rheumatology, Zurich (Switzerland)

    2015-12-15

    To evaluate whether imaging of the trunk could be omitted in patients with inflammatory myopathies without losing diagnostic accuracy using a restricted whole-body magnetic resonance imaging (rWB-MRI) protocol. After approval by the institutional review board, this study was performed in 63 patients (male/female, 13/50; median age, 52 years; range, 20-81 years) with new-onset myopathic symptoms (group 1, n = 41) or previously diagnosed inflammatory myopathy (group 2, n = 22). After performing whole-body MRI (WB-MRI) at 3.0 Tesla, myositis and fatty atrophy were evaluated in different muscles by two independent radiologists. The intra-class correlation coefficient (ICC) was calculated to evaluate inter-observer reliability. Acquisition time was 56:01 minutes for WB-MRI and 37:37 minutes (32.8 % shorter) for rWB-MRI. In group 1, 14 patients were diagnosed with inflammatory myopathy based on muscle biopsy. rWB-MRI and WB-MRI showed equal sensitivity (42.9 %) and specificity (100 %) for myositis, and showed equal sensitivity (71.4 %) and similar specificity (63.0 % and 48.1 %, respectively) for fatty atrophy. No myositis was found in the body trunk in any patient. Inter-observer reliability was between substantial and perfect (ICC, 0.77-1.00). rWB-MRI showed diagnostic accuracy similar to WB-MRI for inflammatory myopathy at markedly reduced overall acquisition time. (orig.)

  11. Enhancement of committed hematopoietic stem cell colony formation by nandrolone decanoate after sublethal whole body irradiation

    International Nuclear Information System (INIS)

    Gallicchio, V.S.; Chen, M.G.; Watts, T.D.

    1984-01-01

    The ability of an anabolic steroid, nandrolone decanoate, to increase committed topoietic stem cell (CFU-gm, CFU-e, and BFU-e) colony formation after sublethal irradiation was evaluated. Immediately after receiving whole body irradiation and on the next two days, each mouse was injected intraperitoneally with nandrolone decanoate (1.25 mg) in propylene glycol. Irradiated control mice received only propylene glycol. Compared to controls, drug-treated mice showed marked peripheral blood leukocytosis and more stable packed red cell volume. Drug-treated mice also demonstrated increased erythropoiesis, as CFU-e/BFU-e concentrations from both marrow (9% to 581%) and spleen (15% to 797%) were elevated. Granulopoiesis was increased similarly, as CFU-gm concentrations from marrow (38% to 685%) and spleen (9% to 373%) were elevated. These results demonstrate that nandrolone decanoate enhances hematopoietic stem cell recovery after sublethal whole body irradiation. This suggests that following hematopoietic suppression, nandrolone decanoate may stimulate the recovery of hematopoiesis at the stem cell level and in peripheral blood

  12. Expression of IL-1β mRNA in mice after whole body X-irradiation

    International Nuclear Information System (INIS)

    Nemoto, Kumie; Ishihara, Hiroshi; Tanaka, Izumi; Suzuki, Gen; Tsuneoka, Kazuko; Yoshida, Kazuko; Ohtsu, Hiroshi

    1995-01-01

    IL-1β is a stimulator of hematopoietic and inflammatory systems, and also acts as a radioprotector. After whole-body exposure to sublethal doses of ionizing radiation, the IL-1β mRNA level in spleen cells increases for a short time prior to regeneration of the spleen. We analyzed spleen cells of C3H/He mice after whole-body irradiation with 3 Gy x-rays to determine the cause of this short-term increase in the transcription level. An increase in the level of the message in spleen cells, found by Northern blot hybridization, reached its peak 5 to 7 days after irradiation. There was a low correlation between the curves of the mRNA level and the ratio of monocyte/macrophage lineage cells; a typical source of the message. Spleen macrophages that produce a large amount of the message were found 7 days after irradiation in an in situ hybridization experiment in which heterogeneous spleen cell populations were used. In contrast, spleen cells had no detectable levels of macrophages rich in IL-1β mRNA before and 17 days after irradiation. Additionally, the population of message-rich cells was 9.4% of the total number of monocytes/macrophages in the spleen. These results suggest that the short-term increase in IL-1β mRNA is a result of the heterogeneous differentiation of a subpopulation of spleen macrophages before regeneration of the spleen. (author)

  13. Low-Dose Adefovir-Induced Hypophosphatemic Osteomalacia on Whole-Body Bone Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Won, Kyoung Sook; Song, Bongil; Jo, Il; Zeon, Seok Kil [Keimyung Univ., Daegu (Korea, Republic of)

    2013-12-15

    While adefovir dipivoxil (ADV) effectively suppresses the hepatitis B virus, it can cause proximal renal tubular dysfunction leading to phosphate wasting. The safety of low-dose ADV (a dose of 10 mg/day), which does not induce clinically significant nephrotoxicity, is well recognized, but a few cases of hypophosphatemic osteomalacia (HO) caused by low-dose ADV therapy have recently been reported. Although HO induced by low-dose ADV therapy is rare, the presence of bone pain in patients treated with ADV should be monitored. Bone scintigraphy can be performed to confirm the occurrence of osteomalacia and to determine the disease extent. Bone scintigraphic and radiological image findings with a brief review of the literature are presented in this article. We report two cases of HO induced by low-dose ADV therapy that showed multifocal increased radiotracer uptakes in the bilateral bony ribs, spines, pelvic bones and lower extremities on whole-body bone scintigraphy. Bone pain gradually improved after phosphate supplementation and by changing the antiviral agent. Whole-body bone scintigraphy is a highly sensitive imaging tool and can show disease extent at once in the setting of the wide range of the clinical spectrum with nonspecific radiological findings. Furthermore, frequent involvement of the lower extremities, as a result of maximum weight bearing, could be an additional scintigraphic clue for the diagnosis of HO. These cases could be helpful for both clinicians prescribing ADV and nuclear physicians to prevent delayed diagnosis and plan further appropriate treatment.

  14. Real-time stylistic prediction for whole-body human motions.

    Science.gov (United States)

    Matsubara, Takamitsu; Hyon, Sang-Ho; Morimoto, Jun

    2012-01-01

    The ability to predict human motion is crucial in several contexts such as human tracking by computer vision and the synthesis of human-like computer graphics. Previous work has focused on off-line processes with well-segmented data; however, many applications such as robotics require real-time control with efficient computation. In this paper, we propose a novel approach called real-time stylistic prediction for whole-body human motions to satisfy these requirements. This approach uses a novel generative model to represent a whole-body human motion including rhythmic motion (e.g., walking) and discrete motion (e.g., jumping). The generative model is composed of a low-dimensional state (phase) dynamics and a two-factor observation model, allowing it to capture the diversity of motion styles in humans. A real-time adaptation algorithm was derived to estimate both state variables and style parameter of the model from non-stationary unlabeled sequential observations. Moreover, with a simple modification, the algorithm allows real-time adaptation even from incomplete (partial) observations. Based on the estimated state and style, a future motion sequence can be accurately predicted. In our implementation, it takes less than 15 ms for both adaptation and prediction at each observation. Our real-time stylistic prediction was evaluated for human walking, running, and jumping behaviors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Response of irradiated diet fed rats to whole body X irradiation

    International Nuclear Information System (INIS)

    Hasan, S.S.; Kushwaha, A.K.S.

    1985-01-01

    The response to whole body X irradiation has been studied in the brain of rats fed both on a normal diet (consisting of equal parts of wheat and gram flour) and on a low protein irradiated diet (consisting of a part of normal diet and three parts of wheat). The activity of enzymes related to the glucose metabolism (glucose 6-phosphate dehydrogenase and fructose diphosphate aldolase) is reduced, while that of peroxidant enzymes (catalase and lipid peroxidase) increased in the brain of rats that received a diet poor in proteins and irradiated diets (normal or hypoproteic). DNA and RNA levels and protein content show a significant reduction in the brain of rats with hypoproteic and irradiated diets. The total body irradiation causes serious alterations in the brain in animals with a hypoproteic malnutritions due both to a low protein and an irradiated diet. The brain of rats fed on a low protein and irradiated diet exhibits after whole body irradiation damages more severe than those in rats fed on a normal irradiated diet

  16. Plutonium fecal and urinary excretion functions: Derivation from a systematic whole-body retention function

    International Nuclear Information System (INIS)

    Sun, C.; Lee, D.

    1999-01-01

    Liver-bile secretion directly influences the content of plutonium in feces. To assess the reliability of plutonium metabolic models and to improve the accuracy of interpreting plutonium fecal data, the authors developed a compartmental model that simulates the metabolism of plutonium in humans. With this model, they can describe the transport of plutonium contaminants in the systemic organs and tissues of the body, including fecal and urine excretions, without using elaborate kinetic information. The parameter values of the models, which describe the translocation rates and recycling of plutonium in the body, can be derived from a multi-term exponential systemic function for whole-body retention. The analytical derivations and algorithms for solving translocation parameter values are established for the model and illustrated by applying them to the biokinetics and bioassay of plutonium. This study describes how to (1) design a physiological model for incorporating liver biliary secretion and for obtaining a fecal-excretion function, (2) develop an analytical solution for identifying the translocation-parameter values incorporating the recycling of plutonium in the body, and (3) derive a set of urinary and fecal excretion-functions from a published systemic whole-body retention function, generally acknowledged to be accurate, as a real and practical example

  17. Hematological profile and martial status in rugby players during whole body cryostimulation.

    Directory of Open Access Journals (Sweden)

    Giovanni Lombardi

    Full Text Available Cold-based therapies are commonly applied to alleviate pain symptoms secondary to inflammatory diseases, but also to treat injuries or overuse, as done in sports rehabilitation. Whole body cryotherapy, a relatively new form of cold therapy, consists of short whole-body exposure to extremely cold air (-110°C to -140°C. Cryostimulation is gaining wider acceptance as an effective part of physical therapy to accelerate muscle recovery in rugby players. The aim of this study was to evaluate the effect of repeated cryostimulation sessions on the hematological profile and martial status markers in professional rugby players. Twenty-seven professional rugby players received 2 daily cryostimulation treatments for 7 consecutive days. Blood samples were collected before and after administration of the cryotherapic protocol and hematological profiles were obtained. No changes in the leukocyte count or composition were seen. There was a decrease in the values for erythrocytes, hematocrit, hemoglobin and mean corpuscular hemoglobin content, and an increase in mean corpuscular volume and red cell distribution width. Platelet count and mean volume remained unchanged. Serum transferrin and ferritin decreased, while soluble transferrin receptor increased. Serum iron and transferrin saturation were unchanged, as was reticulocyte count, whereas the immature reticulocyte fraction decreased substantially. In conclusion, in this sample of professional rugby players, cryostimulation modified the hematological profile, with a reduction in erythrocyte count and hemoglobinization paralleled by a change in martial status markers.

  18. Enhancement recovery of haemostatic system by tocopherol-monoglucoside (TMG) in whole body gamma irradiated rats

    International Nuclear Information System (INIS)

    Elshamy, E.

    2007-01-01

    A preparation of α-tocopherol monoglucoside (TMG) administered intraperitoneally (i.p.) at a dose of 600 mg/kg body wt immediately after whole body gamma-irradiation was examined for its radioprotective efficacy towards some haemostatic parameters (protein C, antithrombin III and tissue plasminogen activators). When rats received gamma-rays at a dose of 6.0 Gy, a marked decrease in plasma protein C and antithrombin 111 activities within the early post-irradiated period was observed. On the other hand, increase in tissue plasminogen activators had been found. Accordingly, whole body y-radiation was found to modulate the coagulation system by down regulating the expression of activated protein C (APC), antithrombins and induction of the fibrinolytic systems by hyper regulating the tissue plasminogen activators, modifying in this way, the balance between pro coagulant and anticoagulant activities and so disturbing the homeostasis. This may lead to micro circulatory disturbance, which plays a role in ischemic organ dysfunction. However, these changes were attenuated in TMG-treated mice. Significant protection of the previous parameters was found for the TMG group of rats. The return to normal value of the reduced protein C and antithrombin Ill starting from the 5th day and the increased plasminogen activators starting from the 12 h interval were less in TMG-treated rats than in untreated irradiated rats. Accordingly, TMG administration was found to enhance haemostatic recovery

  19. Open-Ended Measurement of Whole-Body Movement: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Finn, Michael T. M.

    2018-02-01

    Full Text Available As the importance of embodiment emerges for psychology, there is a need to advance methodology for measuring the dynamics of movement in an open-ended fashion. Such a tool should be versatile across contexts and track spontaneous and natural movement with minimal constraints. We test the feasibility of a method for measuring whole-body movement over time that attempts to meet this need. We use a motion capture system comprised of two Microsoft Kinect version 2.0 cameras and iPiSoft Motion Capture software, and compare its estimates of magnitude rotational velocity and whole-body movement complexity (multivariate multiscale sample entropy; MMSE to that of a gold standard motion capture system across a variety of movement sequences. The candidate system satisfactorily estimated the instantaneous velocity of 13 body segments in agreement with the gold standard system across movement sequences demonstrating initial feasibility of this process. Summary calculations of velocity by sequence and MMSE calculations were also in high agreement with the gold standard, crucially suggesting that the candidate system could pick up on the complex dynamics of movement over time. The candidate system was feasible and demonstrates preliminary validity for general use in the tracking of continuous human movement for clinical and experimental psychology. We also provide R code and sample data for the importing and processing of movement data exported from iPiSoft Motion Capture Studio.

  20. Depiction and characterization of liver lesions in whole body [18F]-FDG PET/MRI

    International Nuclear Information System (INIS)

    Beiderwellen, Karsten; Gomez, Benedikt; Buchbender, Christian; Hartung, Verena; Poeppel, Thorsten D.; Nensa, Felix; Kuehl, Hilmar; Bockisch, Andreas; Lauenstein, Thomas C.

    2013-01-01

    Objectives: To assess the value of PET/MRI with [ 18 F]-FDG using a whole body protocol for the depiction and characterization of liver lesions in comparison to PET/CT. Methods: 70 patients (31 women, 39 men) with solid tumors underwent [ 18 F]-FDG PET/CT and followed by an additional PET/MRI using an integrated scanner. Two readers rated the datasets (PET/CT; PET/MRI) regarding conspicuity of hepatic lesions (4-point ordinal scale) and diagnostic confidence (5-point ordinal scale). Median scores for lesion conspicuity and diagnostic confidence were compared using Wilcoxon's rank sum test. Prior examinations, histopathology and clinical follow-up (116 ± 54 days) served as standard of reference. Results: 36 of 70 (51%) patients showed liver lesions. Using PET/CT and PET/MRI all patients with liver metastases could correctly be identified. A total of 97 lesions were found (malignant n = 26; benign n = 71). For lesion conspicuity significantly higher scores were obtained for PET/MRI in comparison to PET/CT (p < 0.001). Significantly better performance for diagnostic confidence was observed in PET/MRI, both for malignant as for benign lesions (p < 0.001). Conclusions: PET/MRI, even in the setting of a whole body approach, provides higher lesion conspicuity and diagnostic confidence compared to PET/CT and may therefore evolve as an attractive alternative in oncologic imaging