WorldWideScience

Sample records for acuity remained stable

  1. Testbed for High-Acuity Imaging and Stable Photometry

    Science.gov (United States)

    Gregory, James

    This proposal from MIT Lincoln Laboratory (LL) accompanies the NASA/APRA proposal enti-tled THAI-SPICE: Testbed for High-Acuity Imaging - Stable Photometry and Image-Motion Compensa-tion Experiment (submitted by Eliot Young, Southwest Research Institute). The goal of the THAI-SPICE project is to demonstrate three technologies that will help low-cost balloon-borne telescopes achieve diffraction-limited imaging: stable pointing, passive thermal stabilization and in-flight monitoring of the wave front error. This MIT LL proposal supplies a key element of the pointing stabilization component of THAI-SPICE: an electronic camera based on an orthogonaltransfer charge-coupled device (OTCCD). OTCCD cameras have been demonstrated with charge-transfer efficiencies >0.99999, noise of 90%. In addition to supplying a camera with an OTCCD detector, MIT LL will help with integration and testing of the OTCCD with the THAI-SPICE payload’s guide camera.

  2. Tactile acuity charts: a reliable measure of spatial acuity.

    Science.gov (United States)

    Bruns, Patrick; Camargo, Carlos J; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R; Röder, Brigitte

    2014-01-01

    For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  3. Tactile acuity charts: a reliable measure of spatial acuity.

    Directory of Open Access Journals (Sweden)

    Patrick Bruns

    Full Text Available For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  4. Effects of lighting and task parameters on visual acuity and performance

    Energy Technology Data Exchange (ETDEWEB)

    Halonen, L.

    1993-12-31

    Lighting and task parameters and their effects on visual acuity and visual performance are dealt with. The parameters studied are target contrast, target size and subject`s age; and also adaptation luminance, luminance ratio between task and its surrounding and temporal change in luminances are studied. Experiments were carried out to examine the effects of luminance and light spectrum on visual acuity. Young normally sighted, older and low vision people participated in the measurements. In the young and older subject groups the visual acuity remained unchanged at contrasts 0.93 and 0.63 at the luminance range of 15-630 cd/m{sub 2}. The results show that at contrasts 0.03-0.93 young and older subjects` visual acuity remained unchanged in the luminance range of 105-630 cd/m{sub 2}. In the low vision group, the changes in luminances between 25-860 cd/m{sub 2} did not have significant effects on visual acuity measured at high contrast 0.93, at low contrast, slight individual changes were found. The colour temperature of the light sources was altered between 2900-9500 K in the experiment. In the groups of the older, young and low vision subjects the light spectrum did not have significant effects on visual acuity, except for two retinitis pigmentosa subjects. On the basis of the visual acuity experiments, a three dimensional visual acuity model (VA-HUT) has been developed. The model predicts visual acuity as a function of luminance, target contrast and observer age. On the basis of visual acuity experiments visual acuity reserve values have been calculated for different text sizes

  5. The association between higher education and approximate number system acuity.

    Science.gov (United States)

    Lindskog, Marcus; Winman, Anders; Juslin, Peter

    2014-01-01

    Humans are equipped with an approximate number system (ANS) supporting non-symbolic numerosity representation. Studies indicate a relationship between ANS-precision (acuity) and math achievement. Whether the ANS is a prerequisite for learning mathematics or if mathematics education enhances the ANS remains an open question. We investigated the association between higher education and ANS acuity with university students majoring in subjects with varying amounts of mathematics (mathematics, business, and humanities), measured either early (First year) or late (Third year) in their studies. The results suggested a non-significant trend where students taking more mathematics had better ANS acuity and a significant improvement in ANS acuity as a function of study length that was mainly confined to the business students. The results provide partial support for the hypothesis that education in mathematics can enhance the ANS acuity.

  6. The Association Between Higher Education and Approximate Number System Acuity

    Directory of Open Access Journals (Sweden)

    Marcus eLindskog

    2014-05-01

    Full Text Available Humans are equipped with an Approximate Number System (ANS supporting non-symbolic numerosity representation. Studies indicate a relationship between ANS-precision (acuity and math achievement. Whether the ANS is a prerequisite for learning mathematics or if mathematics education enhances the ANS remains an open question. We investigated the association between higher education and ANS acuity with university students majoring in subjects with varying amounts of mathematics (mathematics, business, and humanities, measured either early (1th year or late (3rd year in their studies. The results suggested a non-significant trend where students taking more mathematics had better ANS acuity and a significant improvement in ANS acuity as a function of study length that was mainly confined to the business students. The results provide partial support for the hypothesis that education in mathematics can enhance the ANS acuity.

  7. The association between higher education and approximate number system acuity

    Science.gov (United States)

    Lindskog, Marcus; Winman, Anders; Juslin, Peter

    2014-01-01

    Humans are equipped with an approximate number system (ANS) supporting non-symbolic numerosity representation. Studies indicate a relationship between ANS-precision (acuity) and math achievement. Whether the ANS is a prerequisite for learning mathematics or if mathematics education enhances the ANS remains an open question. We investigated the association between higher education and ANS acuity with university students majoring in subjects with varying amounts of mathematics (mathematics, business, and humanities), measured either early (First year) or late (Third year) in their studies. The results suggested a non-significant trend where students taking more mathematics had better ANS acuity and a significant improvement in ANS acuity as a function of study length that was mainly confined to the business students. The results provide partial support for the hypothesis that education in mathematics can enhance the ANS acuity. PMID:24904478

  8. Repeatability of visual acuity measurement.

    Science.gov (United States)

    Raasch, T W; Bailey, I L; Bullimore, M A

    1998-05-01

    This study investigates features of visual acuity chart design and acuity testing scoring methods which affect the validity and repeatability of visual acuity measurements. Visual acuity was measured using the Sloan and British Standard letter series, and Landolt rings. Identifiability of the different letters as a function of size was estimated, and expressed in the form of frequency-of-seeing curves. These functions were then used to simulate acuity measurements with a variety of chart designs and scoring criteria. Systematic relationships exist between chart design parameters and acuity score, and acuity score repeatability. In particular, an important feature of a chart, that largely determines the repeatability of visual acuity measurement, is the amount of size change attributed to each letter. The methods used to score visual acuity performance also affect repeatability. It is possible to evaluate acuity score validity and repeatability using the statistical principles discussed here.

  9. Visual acuity test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003396.htm Visual acuity test To use the sharing features on this page, please enable JavaScript. The visual acuity test is used to determine the smallest ...

  10. Stable isotopes, niche partitioning and the paucity of elasmosaur remains in the Maastrichtian type area

    NARCIS (Netherlands)

    Schulp, Anne S.; Janssen, Renée; Van Baal, Remy R.; Jagt, John W M; Mulder, Eric W A; Vonhof, Hubert B.

    2017-01-01

    Remains of elasmosaurid plesiosaurs are exceedingly rare in the type-Maastrichtian strata (Late Cretaceous, southeast Netherlands and northeast Belgium), in stark contrast to relatively common skeletal remains of mosasaurs. Here, we present an analysis of δ13C stable isotope values for tooth enamel

  11. 38 CFR 4.76 - Visual acuity.

    Science.gov (United States)

    2010-07-01

    ... DISABILITIES Disability Ratings The Organs of Special Sense § 4.76 Visual acuity. (a) Examination of visual acuity. Examination of visual acuity must include the central uncorrected and corrected visual acuity for... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Visual acuity. 4.76...

  12. Grating-acuity in children. Normal values of visual acuity in children up to 13 years as assessed by the acuity card procedure.

    Science.gov (United States)

    Schenk-Rootlieb, A J; van Nieuwenhuizen, O; van Zoggel, J; van der Graaf, Y; Willemse, J

    1992-09-01

    The acuity card procedure proved to be a useful method for assessing visual acuity in children. Normal values of visual acuity measured by this method had already been assessed in children up to four years. To enable application of the test in older children this study obtained values in a group of 396 normal children, aged three months to 13 years. The mean curve as well as the 10th centile was calculated in different age groups. A considerable variation of acuity values causing a 'dip' in the 10th centile was found in the ages 18 to 24 months. A smaller 'dip' was found in the ages 48 to 52 months. This has to be attributed to behavioural properties connected with age. The results obtained in the group of children under four years of age corresponded fairly well with other studies. In schoolchildren a fair agreement could also be found between the data obtained using the acuity card procedure and the data obtained with the Landolt-C rings. Obtaining normal values for the acuity card procedure in children covering a wide age range facilitates recognition of visual handicap in children who are difficult to assess.

  13. THAI-SPICE: Testbed for High-Acuity Imaging – Stable Photometry and ImageMotion Compensation Experiment

    Science.gov (United States)

    Young, Eliot

    THAI-SPICE is the Testbed for High-Acuity Imaging - Stable Photometry and ImageMotion Compensation Experiment - It is a lead proposal, accompanied by a coInstitutional proposal from MIT LL. The overarching goal of THAI-SPICE is to advance balloonborne telescopes to the point where they can surpass HST in terms of spatial resolution in visible wavelengths and surpass the Kepler mission in terms of observing exoplanet transits. Balloon-borne telescopes are becoming an important part of NASA's observing programs - each 100-day super-pressure balloon flight will provide 1000 hours of dark time observing, equivalent to about 1/3 of the total on-target time allocated in an HST cycle across its entire portfolio of science programs. However, balloon-borne telescopes face unique challenges from the stratospheric thermal environment and the pointing stability of a suspended platform. This proposal will study and test three areas of development that will enable high-acuity image quality and stable photometry from balloon-borne telescopes. - Passive thermal control and stabilization of balloon-borne OTAs (Optical Tube Assemblies). Recent modeling suggests that an appropriate arrangement of sunshields, earth-shields and telescope insulation can reduce diurnal temperature excursions from more than 40°C to less than 2°C. Furthermore, modeling also suggests that the steadystate temperature of an OTA can be reduced to temperatures near 180 K, an advantage for infrared observing programs. However, most modeling packages (e.g., Thermal Desktop) do not accurately account for convection in the 3 torr or 8 torr environment of zeropressure or super-pressure balloons. In fact, it is hard to tell whether radiation or convection is a more significant cooling mechanism at super-pressure balloon altitudes. We propose to verify or update Thermal Desktop results with a series of experiments using an instrumented OTA and sun- and earth-shields. The payoff from this experiment will be balloon

  14. Assessment of Grating Acuity in Infants and Toddlers Using an Electronic Acuity Card: The Dobson Card.

    Science.gov (United States)

    Mohan, Kathleen M; Miller, Joseph M; Harvey, Erin M; Gerhart, Kimberly D; Apple, Howard P; Apple, Deborah; Smith, Jordana M; Davis, Amy L; Leonard-Green, Tina; Campus, Irene; Dennis, Leslie K

    2016-01-01

    To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on the Dobson Card. The Dobson Card consists of a handheld matte-black plexiglass frame with two flush-mounted tablet computers and is similar in size and form to commercially available printed grating acuity testing stimuli (Teller Acuity Cards II [TACII]; Stereo Optical, Inc., Chicago, IL). On each trial, one tablet displayed a square-wave grating and the other displayed a luminance-matched uniform gray patch. Stimuli were roughly equivalent to the stimuli available in the printed TACII stimuli. After acuity testing, each child received a cycloplegic eye examination. Based on cycloplegic retinoscopy, patients were categorized as having high or low refractive error per American Association for Pediatric Ophthalmology and Strabismus vision screening referral criteria. Mean acuities for high and low refractive error groups were compared using analysis of covariance, controlling for age. Mean visual acuity was significantly poorer in children with high refractive error than in those with low refractive error (P = .015). Electronic stimuli presented using the ACP can yield clinically useful measurements of grating acuity in infants and toddlers. Further research is needed to determine the optimal conditions and procedures for obtaining accurate and clinically useful automated measurements of visual acuity in infants and toddlers. Copyright 2016, SLACK Incorporated.

  15. Predicting visual acuity from detection thresholds.

    Science.gov (United States)

    Newacheck, J S; Haegerstrom-Portnoy, G; Adams, A J

    1990-03-01

    Visual performance based exclusively on high luminance and high contrast letter acuity measures often fails to predict individual performance at low contrast and low luminance. Here we measured visual acuity over a wide range of contrasts and luminances (low mesopic to photopic) for 17 young normal observers. Acuity vs. contrast functions appear to fit a single template which can be displaced laterally along the log contrast axis. The magnitude of this lateral displacement for different luminances was well predicted by the contrast threshold difference for a 4 min arc spot. The acuity vs. contrast template, taken from the mean of all 17 subjects, was used in conjunction with individual spot contrast threshold measures to predict an individual's visual acuity over a wide range of luminance and contrast levels. The accuracy of the visual acuity predictions from this simple procedure closely approximates test-retest accuracy for both positive (projected Landolt rings) and negative contrast (Bailey-Lovie charts).

  16. Working conditions remain stable in the Netherlands

    NARCIS (Netherlands)

    Houtman, I.; Hooftman, W.

    2008-01-01

    Despite significant changes in the national questionnaires on work and health, the quality of work as well as health complaints in the Netherlands appear to be relatively stable. Pace of work seems to be on the increase again and more people are working in excess of their contractual hours.

  17. Photometric Compliance of Tablet Screens and Retro-Illuminated Acuity Charts As Visual Acuity Measurement Devices.

    Science.gov (United States)

    Livingstone, I A T; Tarbert, C M; Giardini, M E; Bastawrous, A; Middleton, D; Hamilton, R

    2016-01-01

    Mobile technology is increasingly used to measure visual acuity. Standards for chart-based acuity tests specify photometric requirements for luminance, optotype contrast and luminance uniformity. Manufacturers provide some photometric data but little is known about tablet performance for visual acuity testing. This study photometrically characterised seven tablet computers (iPad, Apple inc.) and three ETDRS (Early Treatment Diabetic Retinopathy Study) visual acuity charts with room lights on and off, and compared findings with visual acuity measurement standards. Tablet screen luminance and contrast were measured using nine points across a black and white checkerboard test screen at five arbitrary brightness levels. ETDRS optotypes and adjacent white background luminance and contrast were measured. All seven tablets (room lights off) exceeded the most stringent requirement for mean luminance (≥ 120 cd/m2) providing the nominal brightness setting was above 50%. All exceeded contrast requirement (Weber ≥ 90%) regardless of brightness setting, and five were marginally below the required luminance uniformity threshold (Lmin/Lmax ≥ 80%). Re-assessing three tablets with room lights on made little difference to mean luminance or contrast, and improved luminance uniformity to exceed the threshold. The three EDTRS charts (room lights off) had adequate mean luminance (≥ 120 cd/m2) and Weber contrast (≥ 90%), but all three charts failed to meet the luminance uniformity standard (Lmin/Lmax ≥ 80%). Two charts were operating beyond manufacturer's recommended lamp replacement schedule. With room lights on, chart mean luminance and Weber contrast increased, but two charts still had inadequate luminance uniformity. Tablet computers showed less inter-device variability, higher contrast, and better luminance uniformity than charts in both lights-on and lights-off environments, providing brightness setting was >50%. Overall, iPad tablets matched or marginally out

  18. Photometric Compliance of Tablet Screens and Retro-Illuminated Acuity Charts As Visual Acuity Measurement Devices.

    Directory of Open Access Journals (Sweden)

    I A T Livingstone

    Full Text Available Mobile technology is increasingly used to measure visual acuity. Standards for chart-based acuity tests specify photometric requirements for luminance, optotype contrast and luminance uniformity. Manufacturers provide some photometric data but little is known about tablet performance for visual acuity testing. This study photometrically characterised seven tablet computers (iPad, Apple inc. and three ETDRS (Early Treatment Diabetic Retinopathy Study visual acuity charts with room lights on and off, and compared findings with visual acuity measurement standards. Tablet screen luminance and contrast were measured using nine points across a black and white checkerboard test screen at five arbitrary brightness levels. ETDRS optotypes and adjacent white background luminance and contrast were measured. All seven tablets (room lights off exceeded the most stringent requirement for mean luminance (≥ 120 cd/m2 providing the nominal brightness setting was above 50%. All exceeded contrast requirement (Weber ≥ 90% regardless of brightness setting, and five were marginally below the required luminance uniformity threshold (Lmin/Lmax ≥ 80%. Re-assessing three tablets with room lights on made little difference to mean luminance or contrast, and improved luminance uniformity to exceed the threshold. The three EDTRS charts (room lights off had adequate mean luminance (≥ 120 cd/m2 and Weber contrast (≥ 90%, but all three charts failed to meet the luminance uniformity standard (Lmin/Lmax ≥ 80%. Two charts were operating beyond manufacturer's recommended lamp replacement schedule. With room lights on, chart mean luminance and Weber contrast increased, but two charts still had inadequate luminance uniformity. Tablet computers showed less inter-device variability, higher contrast, and better luminance uniformity than charts in both lights-on and lights-off environments, providing brightness setting was >50%. Overall, iPad tablets matched or marginally out

  19. [Schoolchildren's visual acuity in the dynamics of learning].

    Science.gov (United States)

    Bezrukikh, M M; Voinov, V B; Kul'ba, S N; Shurygina, I P

    2014-12-01

    The results of the screening study of the acuity of schoolchildren between 7 and 17 years old living in Rostov Region of the Russian Federation are discussed in the article. The method of computer optometry was used to measure acuity. 93772 pupils, 48621 girls and 45151 boys, from 150 schools participated in this examination. It was found that there is sustained growth of those with low acuity (0,2 and less) among children of both sexes from junior group (7 years) to the senior (17). The signs of the decline in visual acuity among girls (14%) are manifested earlier than in boys (8%). The decline in visual acuity among 7-8-year-old children is about 3%. While comparing children from rural areas with those from big cities a true dependence of the parameter (acuity) on the factors (city and sex) was found.

  20. Individual differences in non-verbal number acuity correlate with maths achievement.

    Science.gov (United States)

    Halberda, Justin; Mazzocco, Michèle M M; Feigenson, Lisa

    2008-10-02

    Human mathematical competence emerges from two representational systems. Competence in some domains of mathematics, such as calculus, relies on symbolic representations that are unique to humans who have undergone explicit teaching. More basic numerical intuitions are supported by an evolutionarily ancient approximate number system that is shared by adults, infants and non-human animals-these groups can all represent the approximate number of items in visual or auditory arrays without verbally counting, and use this capacity to guide everyday behaviour such as foraging. Despite the widespread nature of the approximate number system both across species and across development, it is not known whether some individuals have a more precise non-verbal 'number sense' than others. Furthermore, the extent to which this system interfaces with the formal, symbolic maths abilities that humans acquire by explicit instruction remains unknown. Here we show that there are large individual differences in the non-verbal approximation abilities of 14-year-old children, and that these individual differences in the present correlate with children's past scores on standardized maths achievement tests, extending all the way back to kindergarten. Moreover, this correlation remains significant when controlling for individual differences in other cognitive and performance factors. Our results show that individual differences in achievement in school mathematics are related to individual differences in the acuity of an evolutionarily ancient, unlearned approximate number sense. Further research will determine whether early differences in number sense acuity affect later maths learning, whether maths education enhances number sense acuity, and the extent to which tertiary factors can affect both.

  1. How well do you see what you hear? The acuity of visual-to-auditory sensory substitution

    Directory of Open Access Journals (Sweden)

    Alastair eHaigh

    2013-06-01

    Full Text Available Sensory substitution devices (SSDs aim to compensate for the loss of a sensory modality, typically vision, by converting information from the lost modality into stimuli in a remaining modality. The vOICe is a visual-to-auditory SSD which encodes images taken by a camera worn by the user into soundscapes such that an experienced user can extract information about their surroundings. Here we investigated how much detail was resolvable during the early induction stages by testing the acuity of blindfolded sighted, naïve vOICe users. Initial performance was well above chance. Participants who took the test twice as a form of minimal training showed a marked improvement on the second test. Acuity was slightly but not significantly impaired when participants wore a camera and judged letter orientations live. A positive correlation was found between participants’ musical training and their acuity. The relationship between auditory expertise via musical training and the lack of a relationship with visual imagery, suggests that early use of a sensory substitution device draws primarily on the mechanisms of the sensory modality being used rather than the one being substituted. If vision is lost, audition represents the sensory channel of highest bandwidth of those remaining. The level of acuity found here, and the fact it was achieved with very little experience in sensory substitution by naïve users is promising.

  2. Evaluation of contrast visual acuity in patients with retinitis pigmentosa

    Science.gov (United States)

    Oomachi, Kazumi; Ogata, Kazuha; Sugawara, Takeshi; Hagiwara, Akira; Hata, Akira; Yamamoto, Shuichi

    2011-01-01

    Background The purpose of this study was to determine visual acuity at different contrast levels under photopic and mesopic conditions in patients with retinitis pigmentosa. Methods Sixty eyes of 31 normal controls, 92 eyes of 52 patients with retinitis pigmentosa without other ocular disorders (RP-1 group), and 20 eyes of 14 patients with retinitis pigmentosa with cataracts and without other ocular disorders (RP-2 group) were studied. Conventional visual acuity was measured using a conventional Landolt ring chart with 100% contrast and luminance of 150 cd/m2. All of the patients with retinitis pigmentosa had a decimal visual acuity better than 1.0. Contrast visual acuity was measured with the same Landolt ring chart with contrasts of 100% and 10% and under photopic (200 cd/m2) and mesopic (10 cd/m2) conditions. Decimal visual acuities were converted to logMAR units for the analyses. Results The 100% contrast visual acuity and the 10% contrast visual acuity determined under both photopic and mesopic conditions were significantly poorer in both the RP-1 and RP-2 groups than in the controls. The differences between the conventional visual acuity and the 100% contrast visual acuity were significantly greater in the RP-1 and RP-2 groups than in the controls under both photopic and mesopic conditions. The differences between the 100% contrast visual acuity and the 10% contrast visual acuity were not significant among the three groups under photopic and mesopic conditions. Conclusion Contrast visual acuities were greatly reduced in patients with retinitis pigmentosa with relatively well preserved conventional visual acuity, and the contrast visual acuity was largely influenced by ambient light levels in patients with retinitis pigmentosa. Although a longitudinal study for confirmation has to be performed, our findings indicate that contrast visual acuity is a better test to follow changes in visual function in patients with retinitis pigmentosa. PMID:22069346

  3. Color improves ‘visual’ acuity via sound

    Directory of Open Access Journals (Sweden)

    Shelly eLevy-Tzedek

    2014-11-01

    Full Text Available Visual-to-auditory sensory substitution devices (SSDs convey visual information via sound, with the primary goal of making visual information accessible to blind and visually impaired individuals. We developed the EyeMusic SSD, which transforms shape, location and color information into musical notes. We tested the 'visual' acuity of 23 individuals (13 blind and 10 blindfolded sighted on the Snellen tumbling-E test, with the EyeMusic. Participants were asked to determine the orientation of the letter ‘E’. The test was repeated twice: in one test, the letter ‘E’ was drawn with a single color (white, and in the other test, with two colors (red and white. In the latter case, the vertical line in the letter, when upright, was drawn in red, with the three horizontal lines drawn in white. We found no significant differences in performance between the blind and the sighted groups. We found a significant effect of the added color on the ‘visual’ acuity. The highest acuity participants reached in the monochromatic test was 20/800, whereas with the added color, acuity doubled to 20/400. We conclude that color improves 'visual' acuity via sound.

  4. Visual acuity and stereoacuity among mentally retarded children.

    Science.gov (United States)

    Letourneau, J E; Beaulne, C; Duplessis, L

    1992-12-01

    To evaluate the reliability and the validity of Landolt Rings and of the Frisby Test as measures of visual acuity and stereoacuity, respectively, the visual acuity of 30 mentally retarded children was measured with Landolt Rings shown as games, the Sjögren Test, the Dot Visual Acuity Test and stereoacuity with the Frisby Test. Subjects were tested 3 times over a period of 3 weeks to measure the reliability of the tests. No significant difference was observed among these tests. The validity of the Landolt Rings was measured by a correlation of .55 for the highest logMAR values of the Sjögren Test with the highest logMAR values of the Landolt Rings. Visual acuity was systematically lower on the Dot Visual Acuity Test. The Frisby Test was not reliable among a group of 16 normal children who improved systematically over 3 weeks.

  5. Contrast visual acuity after multifocal intraocular lens implantation:aspheric versus spherical design

    Directory of Open Access Journals (Sweden)

    Jun-Hua Li

    2014-02-01

    Full Text Available AIM: To evaluate contrast visual acuity (CVA after implantation of an aspheric apodized diffractive intraocular lens (IOL or a spherical apodized diffractive IOL in cataract surgery.METHOD: This prospective randomized controlled study with a 12-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL (30 eyes and a spherical AcrySof ReSTOR SN60D3 IOL (30 eyes. CVA with best distance correction was measured at 4 contrast levels (100%, 25%, 10% and 5% under 3 levels of chart luminance [250, 85 and 25 candelas per square meter (cd/m2] using a multi-functional visual acuity tester (MFVA-100.RESULTS:At 12 months after surgery, there were no statistically significant differences in 100% CVA and 25% CVA under 250cd/m2 (P100%=0.875 and P25%=0.057 and 85cd/m2 (P100%=0.198 and P25%=0.193 between the aspheric group and the spherical group. However, the 10% CVA and 5% CVA were significant better in aspheric group than spherical group under 250cd/m2 (P10%=0.042 and P5%=0.007 and 85cd/m2 (P10%=0.002 and P5%=0.039. Under the luminance level of 25cd/m2, no significant differences was found in the 100% CVA between the 2 group (P100%=0.245, while aspheric group had better visual acuity in the remaining 3 contracts (P25%=0.023, P10%=0.026 and P5%=0.002, respectively.CONCULSION:The aspheric AcrySof ReSTOR SN6AD3 IOL provided patients with better low-contrast visual acuity than the spherical AcrySof ReSTOR SN60D3 IOL.Keyword:cataract surgery; intraocular lens; contrast sensitivity; visual acuity

  6. 21 CFR 886.1150 - Visual acuity chart.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual acuity chart. 886.1150 Section 886.1150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1150 Visual acuity chart. (a) Identification...

  7. Contributing factors to VEP grating acuity deficit and inter-ocular acuity difference in children with cerebral visual impairment.

    Science.gov (United States)

    Cavascan, Nívea Nunes; Salomão, Solange Rios; Sacai, Paula Yuri; Pereira, Josenilson Martins; Rocha, Daniel Martins; Berezovsky, Adriana

    2014-04-01

    To investigate contributing factors to visual evoked potential (VEP) grating acuity deficit (GAD) and inter-ocular acuity difference (IAD) measured by sweep-VEPs in children with cerebral visual impairment (CVI). VEP GAD was calculated for the better acuity eye by subtracting acuity thresholds from mean normal VEP grating acuity according to norms from our own laboratory. Deficits were categorized as mild (0.17 ≤ deficit children (66 males-57 %) with ages ranging from 1.2 to 166.5 months (median = 17.7) was examined. VEP GAD ranged from 0.17 to 1.28 log units (mean = 0.68 ± 0.27; median = 0.71), and it was mild in 23 (20 %) children, moderate in 32 (28 %) and severe in 60 (52 %). Severe deficit was significantly associated with older age and anti-seizure drug therapy. IAD ranged from 0 to 0.49 log units (mean = 0.06 ± 0.08; median = 0.04) and was acceptable in 96 (83 %) children. Children with strabismus and nystagmus had IAD significantly larger compared to children with orthoposition. In a large cohort of children with CVI, variable severity of VEP GAD was found, with more than half of the children with severe deficits. Older children and those under anti-seizure therapy were at higher risk for larger deficits. Strabismus and nystagmus provided larger IADs. These results should be taken into account on the clinical management of children with this leading cause of bilateral visual impairment.

  8. VEP-based acuity assessment in low vision.

    Science.gov (United States)

    Hoffmann, Michael B; Brands, Jan; Behrens-Baumann, Wolfgang; Bach, Michael

    2017-12-01

    Objective assessment of visual acuity (VA) is possible with VEP methodology, but established with sufficient precision only for vision better than about 1.0 logMAR. We here explore whether this can be extended down to 2.0 logMAR, highly desirable for low-vision evaluations. Based on the stepwise sweep algorithm (Bach et al. in Br J Ophthalmol 92:396-403, 2008) VEPs to monocular steady-state brief onset pattern stimulation (7.5-Hz checkerboards, 40% contrast, 40 ms on, 93 ms off) were recorded for eight different check sizes, from 0.5° to 9.0°, for two runs with three occipital electrodes in a Laplace-approximating montage. We examined 22 visually normal participants where acuity was reduced to ≈ 2.0 logMAR with frosted transparencies. With the established heuristic algorithm the "VEP acuity" was extracted and compared to psychophysical VA, both obtained at 57 cm distance. In 20 of the 22 participants with artificially reduced acuity the automatic analysis indicated a valid result (1.80 logMAR on average) in at least one of the two runs. 95% test-retest limits of agreement on average were ± 0.09 logMAR for psychophysical, and ± 0.21 logMAR for VEP-derived acuity. For 15 participants we obtained results in both runs and averaged them. In 12 of these 15 the low-acuity results stayed within the 95% confidence interval (± 0.3 logMAR) as established by Bach et al. (2008). The fully automated analysis yielded good agreement of psychophysical and electrophysiological VAs in 12 of 15 cases (80%) in the low-vision range down to 2.0 logMAR. This encourages us to further pursue this methodology and assess its value in patients.

  9. Empiric determination of corrected visual acuity standards for train crews.

    Science.gov (United States)

    Schwartz, Steven H; Swanson, William H

    2005-08-01

    Probably the most common visual standard for employment in the transportation industry is best-corrected, high-contrast visual acuity. Because such standards were often established absent empiric linkage to job performance, it is possible that a job applicant or employee who has visual acuity less than the standard may be able to satisfactorily perform the required job activities. For the transportation system that we examined, the train crew is required to inspect visually the length of the train before and during the time it leaves the station. The purpose of the inspection is to determine if an individual is in a hazardous position with respect to the train. In this article, we determine the extent to which high-contrast visual acuity can predict performance on a simulated task. Performance at discriminating hazardous from safe conditions, as depicted in projected photographic slides, was determined as a function of visual acuity. For different levels of visual acuity, which was varied through the use of optical defocus, a subject was required to label scenes as hazardous or safe. Task performance was highly correlated with visual acuity as measured under conditions normally used for vision screenings (high-illumination and high-contrast): as the acuity decreases, performance at discriminating hazardous from safe scenes worsens. This empirically based methodology can be used to establish a corrected high-contrast visual acuity standard for safety-sensitive work in transportation that is linked to the performance of a job-critical task.

  10. [The relationship between eyeball structure and visual acuity in high myopia].

    Science.gov (United States)

    Liu, Yi-Chang; Xia, Wen-Tao; Zhu, Guang-You; Zhou, Xing-Tao; Fan, Li-Hua; Liu, Rui-Jue; Chen, Jie-Min

    2010-06-01

    To explore the relationship between eyeball structure and visual acuity in high myopia. Totally, 152 people (283 eyeballs) with different levels of myopia were tested for visual acuity, axial length, and fundus. All cases were classified according to diopter, axial length, and fundus. The relationships between diopter, axial length, fundus and visual acuity were studied. The mathematical models were established for visual acuity and eyeball structure markers. The visual acuity showed a moderate correlation with fundus class, comus, axial length and diopter ([r] > 0.4, P eyeball structure markers. The visual acuity should decline with axial length extension, diopter deepening and pathological deterioration of fundus. To detect the structure changes by combining different kinds of objective methods can help to assess and to judge the vision in high myopia.

  11. Association between individual differences in non-symbolic number acuity and math performance: a meta-analysis.

    Science.gov (United States)

    Chen, Qixuan; Li, Jingguang

    2014-05-01

    Many recent studies have examined the association between number acuity, which is the ability to rapidly and non-symbolically estimate the quantity of items appearing in a scene, and symbolic math performance. However, various contradictory results have been reported. To comprehensively evaluate the association between number acuity and symbolic math performance, we conduct a meta-analysis to synthesize the results observed in previous studies. First, a meta-analysis of cross-sectional studies (36 samples, N = 4705) revealed a significant positive correlation between these skills (r = 0.20, 95% CI = [0.14, 0.26]); the association remained after considering other potential moderators (e.g., whether general cognitive abilities were controlled). Moreover, a meta-analysis of longitudinal studies revealed 1) that number acuity may prospectively predict later math performance (r = 0.24, 95% CI = [0.11, 0.37]; 6 samples) and 2) that number acuity is retrospectively correlated to early math performance as well (r = 0.17, 95% CI = [0.07, 0.26]; 5 samples). In summary, these pieces of evidence demonstrate a moderate but statistically significant association between number acuity and math performance. Based on the estimated effect sizes, power analyses were conducted, which suggested that many previous studies were underpowered due to small sample sizes. This may account for the disparity between findings in the literature, at least in part. Finally, the theoretical and practical implications of our meta-analytic findings are presented, and future research questions are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. A case-control study of visual acuity in onychocryptosis.

    LENUS (Irish Health Repository)

    Hogan, Aisling M

    2012-02-01

    BACKGROUND: There are many theories surrounding the etiology of ingrown toenails (IGTN). Few factors have been formally assessed, but it is widely accepted that a poor nail cutting technique has a causative role. AIM: To investigate the hypothesis that decreased visual acuity may lead to inadequate nail cutting and the formation of IGTN. METHODS: A prospective case-control study was performed. Near and distance visual acuity were tested on a population with IGTN (n = 19) and compared with that of an age- and sex-matched control cohort (n = 24) who underwent epidermal cyst excision in the same tertiary referral center. Comparisons of visual acuity were made between groups by Mann-Whitney U-test. Differences were taken to be significant if P < 0.05. Institutional Review Board approval was sought and granted. RESULTS: No significant difference in visual acuity (near or distance) was demonstrated between patients with IGTN and the control group (P = 0.33). CONCLUSION: Visual acuity does not appear to play a significant role in the development of IGTN.

  13. [Determining visual acuity with LH symbols and Landolt rings].

    Science.gov (United States)

    Gräf, M; Becker, R

    1999-08-01

    Lea (LH) symbols seem to be favourable for visual acuity assessment in childhood. The symbols of the LH test are well standardized and applicable to preschool children. We compared the visual acuity determined by LH single symbols (LH) and the acuity measured with the Landolt-C (LC). 138 cooperative subjects aged 7 to 91 years were examined. Their visual acuity was either normal or reduced due to various etiologies. Their refractive error was corrected. The monocular LH and LC were determined by a 3/4 criterion (study 1). In 19 healthy subjects aged 21 to 58 years, acuity was reduced stepwise by 5 different calibrated occlusives (study 2). A Lighthouse single symbol book (LH symbols) was used at a distance of 3 m. LC was determined at a distance of 5 m. The luminance of the test field was 180-200 cd/m2. The right eye of each patient and the amblyopic eye of the squinting patients was taken for statistical evaluation. The strabismic patients' interocular differences of LC and LH were compared. Within study 1, LC ranged from 0.02 to 2.0 and LH from 0.03 to 2.5. LH overestimated LC by 1.4 lines on an average (t-test p 1 line, 85.7% resp. 90% of the strabismic amblyopic patients with an interocular LC difference > 1 resp > 2 lines were detected. In study 2, LC ranged from 0.1 to 1.6, LH from 0.12 to 2.0. The mean difference LH-LC was 1.3 lines. The regression equation was lgLH = 0.91 lgLC + 0.08 (r = 0.95). LH symbols allow a reliable measurement of recognition acuity. Due to the design of the symbols, they are excellently suitable for application to preschool children. Age related normal values should be established. The systematic difference between the LC acuity and the LH acuity measured with the Lighthouse LH single symbol book by 1.4 lines has to be considered.

  14. Preschool acuity of the approximate number system correlates with school math ability.

    Science.gov (United States)

    Libertus, Melissa E; Feigenson, Lisa; Halberda, Justin

    2011-11-01

    Previous research shows a correlation between individual differences in people's school math abilities and the accuracy with which they rapidly and nonverbally approximate how many items are in a scene. This finding is surprising because the Approximate Number System (ANS) underlying numerical estimation is shared with infants and with non-human animals who never acquire formal mathematics. However, it remains unclear whether the link between individual differences in math ability and the ANS depends on formal mathematics instruction. Earlier studies demonstrating this link tested participants only after they had received many years of mathematics education, or assessed participants' ANS acuity using tasks that required additional symbolic or arithmetic processing similar to that required in standardized math tests. To ask whether the ANS and math ability are linked early in life, we measured the ANS acuity of 200 3- to 5-year-old children using a task that did not also require symbol use or arithmetic calculation. We also measured children's math ability and vocabulary size prior to the onset of formal math instruction. We found that children's ANS acuity correlated with their math ability, even when age and verbal skills were controlled for. These findings provide evidence for a relationship between the primitive sense of number and math ability starting early in life. 2011 Blackwell Publishing Ltd.

  15. Tactile spatial acuity in childhood: effects of age and fingertip size.

    Directory of Open Access Journals (Sweden)

    Ryan M Peters

    Full Text Available Tactile acuity is known to decline with age in adults, possibly as the result of receptor loss, but less is understood about how tactile acuity changes during childhood. Previous research from our laboratory has shown that fingertip size influences tactile spatial acuity in young adults: those with larger fingers tend to have poorer acuity, possibly because mechanoreceptors are more sparsely distributed in larger fingers. We hypothesized that a similar relationship would hold among children. If so, children's tactile spatial acuity might be expected to worsen as their fingertips grow. However, concomitant CNS maturation might result in more efficient perceptual processing, counteracting the effect of fingertip growth on tactile acuity. To investigate, we conducted a cross-sectional study, testing 116 participants ranging in age from 6 to 16 years on a precision-controlled tactile grating orientation task. We measured each participant's grating orientation threshold on the dominant index finger, along with physical properties of the fingertip: surface area, volume, sweat pore spacing, and temperature. We found that, as in adults, children with larger fingertips (at a given age had significantly poorer acuity, yet paradoxically acuity did not worsen significantly with age. We propose that finger growth during development results in a gradual decline in innervation density as receptive fields reposition to cover an expanding skin surface. At the same time, central maturation presumably enhances perceptual processing.

  16. Retention of high tactile acuity throughout the life span in blindness.

    Science.gov (United States)

    Legge, Gordon E; Madison, Cindee; Vaughn, Brenna N; Cheong, Allen M Y; Miller, Joseph C

    2008-11-01

    Previous studies of tactile acuity on the fingertip, using passive touch, have demonstrated an age-related decline in spatial resolution for both sighted and blind subjects. We have reexamined this age dependence with two newly designed tactile-acuity charts that require active exploration of the test symbols. One chart used dot patterns similar to braille, and the other used embossed Landolt rings. Groups of blind braille readers and sighted subjects ranging from 12 to 85 years old were tested in two experiments. We replicated previous findings for sighted subjects by showing an age-related decrease in tactile acuity by nearly 1% per year. Surprisingly, the blind subjects retained high acuity into old age, showing no age-related decline. For the blind subjects, tactile acuity did not correlate with braille reading speed, the amount of daily reading, or the age at which braille was learned. We conclude that when measured with active touch, blind subjects retain high tactile acuity into old age, unlike their aging sighted peers. We propose that blind people's use of active touch in daily activities, not specifically braille reading, results in preservation of tactile acuity across the life span.

  17. Acuity and case management: a healthy dose of outcomes, part III.

    Science.gov (United States)

    Huber, Diane L; Craig, Kathy

    2007-01-01

    This is the third of a 3-part series presenting 2 effective applications--acuity and dosage--that describe how the business case for case management (CM) can be made. In Part I, dosage and acuity concepts were explained as client need-severity, CM intervention-intensity, and CM activity-dose prescribed by amount, frequency, duration, and breadth of activities. Concepts were presented that related the practice of CM to the use of evidence-based practice (EBP), knowledge, and methods and the development of instruments that measure and score pivotal CM actions. Part I also featured a specific exemplar, the CM Acuity Tool, and described how to use acuity to identify and score the complexity of a CM case. Part II further explained dosage and 2 acuity instruments, the Acuity Tool and AccuDiff. Part III presents linkage to EBP and practical applications. The information contained in the 3-part series applies to all CM practice settings and contains ideas and recommendations useful to CM generalists, specialists, supervisors, and business and outcomes managers. The Acuity Tools Project was developed from frontline CM practice in one large, national telephonic CM company. Dosage: A literature search failed to find research into dosage of a behavioral intervention. The Huber-Hall model was developed and tested in a longitudinal study of CM models in substance abuse treatment and reported in the literature. Acuity: A structured literature search and needs assessment launched the development of the suite of acuity tools. A gap analysis identified that an instrument to assign and measure case acuity specific to CM activities was needed. Clinical experts, quality specialists, and business analysts (n = 7) monitored the development and testing of the tools, acuity concepts, scores, differentials, and their operating principles and evaluated the validity of the acuity tools' content related to CM activities. During the pilot phase of development, interrater reliability testing of

  18. Acuity and case management: a healthy dose of outcomes, part II.

    Science.gov (United States)

    Craig, Kathy; Huber, Diane L

    2007-01-01

    This is the second of a 3-part series presenting 2 effective applications-acuity and dosage-that describe how the business case for case management (CM) can be made. In Part I, dosage and acuity concepts were explained as client need-severity, CM intervention-intensity, and CM activity-dose prescribed by amount, frequency, duration, and breadth of activities. Part I also featured a specific exemplar, the CM Acuity Tool, and described how to use acuity to identify and score the complexity of a CM case. Appropriate dosage prescription of CM activity was discussed. Part II further explains dosage and presents two acuity instruments, the Acuity Tool and AccuDiff. Details are provided that show how these applications produce opportunities for better communication about CM cases and for more accurate measurement of the right content that genuinely reflects the essentials of CM practice. The information contained in the 3-part series applies to all CM practice settings and contains ideas and recommendations useful to CM generalists, specialists, and supervisors, plus business and outcomes managers. The Acuity Tools Project was developed from frontline CM practice in one large, national telephonic CM company. Dosage: A literature search failed to find research into dosage of a behavioral intervention. The Huber-Hall model was developed and tested in a longitudinal study of CM models in substance abuse treatment and reported in the literature. Acuity: A structured literature search and needs assessment launched the development of the suite of acuity tools. A gap analysis identified that an instrument to assign and measure case acuity specific to CM activities was needed. Clinical experts, quality specialists, and business analysts (n = 7) monitored the development and testing of the tools, acuity concepts, scores, differentials, and their operating principles and evaluated the validity of the Acuity Tools' content related to CM activities. During the pilot phase of

  19. Relationships between luminance and visual acuity in the rhesus monkey

    Science.gov (United States)

    Cavonius, C. R.; Robbins, D. O.

    1973-01-01

    1. The ability of rhesus monkeys to detect the gap in Landolt ring test-objects that were presented against background luminances between 5 × 10-5 cd/m2 and 5 × 103 cd/m2 was compared with similar human data. 2. At high luminance-levels the acuity of human observers is slightly better than that of rhesus, but rhesus have better acuity at scotopic luminance-levels. Both species have distinct photopic and scotopic acuity functions that cross at 6 × 10-3 cd/m2. 3. The threshold for light detection is estimated to be the same for both species when specified in quanta incident on the retina. 4. It is concluded that the receptor and neural mechanisms that mediate visual-acuity function similarly in rhesus and man, and that the differences in acuity that were measured in the two species may be attributed to optical rather than to physiological factors. PMID:4199366

  20. Distinct Circuits for Recovery of Eye Dominance and Acuity in Murine Amblyopia.

    Science.gov (United States)

    Stephany, Céleste-Élise; Ma, Xiaokuang; Dorton, Hilary M; Wu, Jie; Solomon, Alexander M; Frantz, Michael G; Qiu, Shenfeng; McGee, Aaron W

    2018-05-24

    Degrading vision by one eye during a developmental critical period yields enduring deficits in both eye dominance and visual acuity. A predominant model is that "reactivating" ocular dominance (OD) plasticity after the critical period is required to improve acuity in amblyopic adults. However, here we demonstrate that plasticity of eye dominance and acuity are independent and restricted by the nogo-66 receptor (ngr1) in distinct neuronal populations. Ngr1 mutant mice display greater excitatory synaptic input onto both inhibitory and excitatory neurons with restoration of normal vision. Deleting ngr1 in excitatory cortical neurons permits recovery of eye dominance but not acuity. Reciprocally, deleting ngr1 in thalamus is insufficient to rectify eye dominance but yields improvement of acuity to normal. Abolishing ngr1 expression in adult mice also promotes recovery of acuity. Together, these findings challenge the notion that mechanisms for OD plasticity contribute to the alterations in circuitry that restore acuity in amblyopia. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. PATTERN ELECTRORETINOGRAPHY IN RELATION TO KINETIC AND STATIC PERIMETRY AND VISUAL ACUITY IN RETINITIS PIGMENTOSA

    Directory of Open Access Journals (Sweden)

    Petra Popović

    2002-12-01

    related to the remaining functional retina. The agreement is more pronounced in static than kinetic perimetry. Visual acuity affects the pattern ERG more than flash ERG.

  2. Visual acuity and visual field impairment in Usher syndrome.

    Science.gov (United States)

    Edwards, A; Fishman, G A; Anderson, R J; Grover, S; Derlacki, D J

    1998-02-01

    To determine the extent of visual acuity and visual field impairment in patients with types 1 and 2 Usher syndrome. The records of 53 patients with type 1 and 120 patients with type 2 Usher syndrome were reviewed for visual acuity and visual field area at their most recent visit. Visual field areas were determined by planimetry of the II4e and V4e isopters obtained with a Goldmann perimeter. Both ordinary and logistic regression models were used to evaluate differences in visual acuity and visual field impairment between patients with type 1 and type 2 Usher syndrome. The difference in visual acuity of the better eye between patients with type 1 and type 2 varied by patient age (P=.01, based on a multiple regression model). The maximum difference in visual acuity between the 2 groups occurred during the third and fourth decades of life (with the type 1 patients being more impaired), while more similar acuities were seen in both younger and older patients. Fifty-one percent (n=27) of the type 1 patients had a visual acuity of 20/40 or better in at least 1 eye compared with 72% (n=87) of the type 2 patients (age-adjusted odds ratio, 3.9). Visual field area to both the II4e (P=.001) and V4e (Ptype 1 patients than type 2 patients. A concentric central visual field greater than 20 degrees in at least 1 eye was present in 20 (59%) of the available 34 visual fields of type 1 patients compared with 70 (67%) of the available 104 visual fields of type 2 patients (age-adjusted odds ratio, 2.9) with the V4e target and in 6 (21%) of the available 29 visual fields of type 1 patients compared with 36 (38%) of the available 94 visual fields of type 2 patients (age-adjusted odds ratio, 4.9) with the II4e target. The fraction of patients who had a visual acuity of 20/40 or better and a concentric central visual field greater than 20 degrees to the II4e target in at least 1 eye was 17% (n=5) in the type 1 patients and 35% (n=33) in the type 2 patients (age-adjusted odds ratio, 3

  3. An acuity cards cookbook.

    Science.gov (United States)

    Vital-Durand, F

    1996-01-01

    Acuity cards are being more commonly used in clinical and screening practice. The author describes his experience from over 6000 infants tested with the method, using two commercially available sets of cards to provide users with comprehensive guidelines to allow them to get the most out of this useful test.

  4. Development and clinical application of a color pediatric visual acuity chart

    Directory of Open Access Journals (Sweden)

    Shu-Guo Yin

    2014-12-01

    Full Text Available AIM: To introduce a new color pediatric visual acuity chart and its clinical application.METHODS:The color pediatric visual acuity chart was designed based on principle of visual angle. The optotype on the color chart had graphics. The progression rate of optotype size between 2 lines was 10(101/2 and 1.2589. A regular geometric progression of optotype sizes and distribution was employed to arrange 8 lines with 11 optotype on the color chart. The testing distance was 3m. The visual acuity score could be recorded as logarithm of the minimum angle of resolution notation or decimal notation. The reliability of naked distant measurements with this new chart was tested in one eye of 100 children(4 ~6 years oldtaking the Chinese national standard logarithm visual acuity chart standard. RESULTS: The color pediatric visual acuity chart and logarithmic chart controls, visual acuity test results that in the two groups had no significant difference(t=1.2671, P>0.05. Two sets of vision data existed positive correlation(r=0.924, PCONCLUSION:Children are easier to accept used new color pediatric visual acuity chart to inspect vision. New chart is reliability and apply to children's vision screening.

  5. Human locognosic acuity on the arm varies with explicit and implicit manipulations of attention: implications for interpreting elevated tactile acuity on an amputation stump.

    Science.gov (United States)

    O'Boyle, D J; Moore, C E; Poliakoff, E; Butterworth, R; Sutton, A; Cody, F W

    2001-06-01

    In Experiment 1, normal subjects' ability to localize tactile stimuli (locognosia) delivered to the upper arm was significantly higher when they were instructed explicitly to direct their attention selectively to that segment than when they were instructed explicitly to distribute their attention across the whole arm. This elevation of acuity was eliminated when subjects' attentional resources were divided by superimposition of an effortful, secondary task during stimulation. In Experiment 2, in the absence of explicit attentional instruction, subjects' locognosic acuity on one of three arm segments was significantly higher when stimulation of that segment was 2.5 times more probable than that of stimulation of the other two segments. We surmise that the attentional mechanisms responsible for such modulations of locognosic acuity in normal subjects may contribute to the elevated sensory acuity observed on the stumps of amputees.

  6. Gender and environmental influences on visual acuity in Owerri ...

    African Journals Online (AJOL)

    This study assessed the gender and environmental influences on visual function among adults in Owerri, Nigeria. Visual acuity (V.A.) is a measure of visual function in health and disease. Visual disability together with other disabling conditions is a barrier to development, yet there is little known about the visual acuity and ...

  7. The high cost of low-acuity ICU outliers.

    Science.gov (United States)

    Dahl, Deborah; Wojtal, Greg G; Breslow, Michael J; Holl, Randy; Huguez, Debra; Stone, David; Korpi, Gloria

    2012-01-01

    Direct variable costs were determined on each hospital day for all patients with an intensive care unit (ICU) stay in four Phoenix-area hospital ICUs. Average daily direct variable cost in the four ICUs ranged from $1,436 to $1,759 and represented 69.4 percent and 45.7 percent of total hospital stay cost for medical and surgical patients, respectively. Daily ICU cost and length of stay (LOS) were higher in patients with higher ICU admission acuity of illness as measured by the APACHE risk prediction methodology; 16.2 percent of patients had an ICU stay in excess of six days, and these LOS outliers accounted for 56.7 percent of total ICU cost. While higher-acuity patients were more likely to be ICU LOS outliers, 11.1 percent of low-risk patients were outliers. The low-risk group included 69.4 percent of the ICU population and accounted for 47 percent of all LOS outliers. Low-risk LOS outliers accounted for 25.3 percent of ICU cost and incurred fivefold higher hospital stay costs and mortality rates. These data suggest that severity of illness is an important determinant of daily resource consumption and LOS, regardless of whether the patient arrives in the ICU with high acuity or develops complications that increase acuity. The finding that a substantial number of long-stay patients come into the ICU with low acuity and deteriorate after ICU admission is not widely recognized and represents an important opportunity to improve patient outcomes and lower costs. ICUs should consider adding low-risk LOS data to their quality and financial performance reports.

  8. Arithmetic Training Does Not Improve Approximate Number System Acuity

    Directory of Open Access Journals (Sweden)

    Marcus Lindskog

    2016-10-01

    Full Text Available The Approximate Number System (ANS is thought to support non-symbolic representations of numerical magnitudes in humans. Recently much debate has focused on the causal direction for an observed relation between ANS acuity and arithmetic fluency. Here we investigate if arithmetic training can improve ANS acuity. We show with an experimental training study consisting of six 45-minute training sessions that although feedback during arithmetic training improves arithmetic performance substantially, it does not influence ANS acuity. Hence, we find no support for a causal link where symbolic arithmetic training influences the ANS acuity. Further, although short-term number memory is likely involved in arithmetic tasks we did not find that short-term memory capacity for numbers, measured by a digit-span test, was effected by arithmetic training. This suggests that the improvement in arithmetic fluency may have occurred independent of short-term memory efficiency, but rather due to long-term memory processes and/or mental calculation strategy development. The theoretical implications of these findings are discussed.

  9. Stable strontium isotopic ratios from archaeological organic remains from the Thorsberg peat bog

    DEFF Research Database (Denmark)

    Nosch, Marie-Louise Bech; von Carnap-Bornheim, Claus; Grupe, Gisela

    2007-01-01

    Pilot study analysing stable strontium isotopic ratios from Iron Age textile and leather finds from the Thorsberg peat bog.......Pilot study analysing stable strontium isotopic ratios from Iron Age textile and leather finds from the Thorsberg peat bog....

  10. Improvement of visual acuity by refraction in a low-vision population.

    Science.gov (United States)

    Sunness, Janet S; El Annan, Jaafar

    2010-07-01

    Refraction often may be overlooked in low-vision patients, because the main cause of vision decrease is not refractive, but rather is the result of underlying ocular disease. This retrospective study was carried out to determine how frequently and to what extent visual acuity is improved by refraction in a low-vision population. Cross-sectional study. Seven hundred thirty-nine low-vision patients seen for the first time. A database with all new low-vision patients seen from November 2005 through June 2008 recorded presenting visual acuity using an Early Treatment Diabetic Retinopathy Study chart; it also recorded the best-corrected visual acuity (BCVA) if it was 2 lines or more better than the presenting visual acuity. Retinoscopy was carried out on all patients, followed by manifest refraction. Improvement in visual acuity. Median presenting acuity was 20/80(-2) (interquartile range, 20/50-20/200). There was an improvement of 2 lines or more of visual acuity in 81 patients (11% of all patients), with 22 patients (3% of all patients) improving by 4 lines or more. There was no significant difference in age or in presenting visual acuity between the group that did not improve by refraction and the group that did improve. When stratified by diagnosis, the only 2 diagnoses with a significantly higher rate of improvement than the age-related macular degeneration group were myopic degeneration and progressive myopia (odds ratio, 4.8; 95% confidence interval [CI], 3.0-6.7) and status post-retinal detachment (odds ratio, 7.1; 95% CI, 5.2-9.0). For 5 patients (6% of those with improvement), the eye that was 1 line or more worse than the fellow eye at presentation became the eye that was 1 line or more better than the fellow eye after refraction. A significant improvement in visual acuity was attained by refraction in 11% of the new low-vision patients. Improvement was seen across diagnoses and the range of presenting visual acuity. The worse-seeing eye at presentation may

  11. Visual Acuity in Primary School Pupils in Lagos, Nigeria | Okoro ...

    African Journals Online (AJOL)

    ... in visual acuity. Conclusion: Eye defects occur among school children with potential negative effects. Pre-school entry eye examinations and regular screening is advocated and glasses should be made available for children with refractive error. Keywords: Visual Acuity, Screening, School Children, School Health ...

  12. Modelling the training effects of kinaesthetic acuity measurement in children.

    Science.gov (United States)

    Sims, K; Morton, J

    1998-07-01

    In previous papers (Sims, Henderson, Hulme, & Morton, 1996a; Sims, Henderson, Morton, & Hulme, 1996b) we have found that the motor skills of clumsy children are capable of significant improvement following relatively brief interventions. Most remarkably, this included a 10-minute intervention while testing the kinaesthetic acuity of the children using a staircase method (Pest). In this paper, we show that Pest testing improves the kinaesthetic acuity of normal children as well. We analyse the available data on the development and improvement of motor skills and kinaesthetic acuity and derive a causal model for the underlying skills. We show that at least three independent cognitive/biological components are required to account for the data. These three components are affected differently by the various interventions that have been tried. We deduce that improvement on a general test of motor impairment can be found as a result of training in kinaesthetic acuity or through other, independent factors.

  13. Cerebral water and ion balance remains stable when humans are exposed to acute hypoxic exercise

    DEFF Research Database (Denmark)

    Avnstorp, Magnus B; Rasmussen, Peter; Brassard, Patrice

    2015-01-01

    both circumstances. No cerebral net exchange of Na(+) or K(+) was evident. Likewise, no significant net-exchange of water over the brain was demonstrated and the arterial and jugular venous hemoglobin concentrations were similar. CONCLUSION: Challenging exercise in hypoxia for 30 min affected muscle......Avnstorp, Magnus B., Peter Rasmussen, Patrice Brassard, Thomas Seifert, Morten Overgaard, Peter Krustrup, Niels H. Secher, and Nikolai B. Nordsborg. Cerebral water and ion balance remains stable when humans are exposed to acute hypoxic exercise. High Alt Med Biol 16:000-000, 2015.-Background...... intense exercise is carried out in hypoxia and monitored the influence of muscle metabolism for changes in arterial variables. METHODS: On two separate days, in random order, 30 min cycling exercise was performed in either hypoxia (10% O2) or normoxia at an intensity that was exhaustive in the hypoxic...

  14. When approximate number acuity predicts math performance: The moderating role of math anxiety

    Science.gov (United States)

    Libertus, Melissa E.

    2018-01-01

    Separate lines of research suggest that people who are better at estimating numerical quantities using the approximate number system (ANS) have better math performance, and that people with high levels of math anxiety have worse math performance. Only a handful of studies have examined both ANS acuity and math anxiety in the same participants and those studies report contradictory results. To address these inconsistencies, in the current study 87 undergraduate students completed assessments of ANS acuity, math anxiety, and three different measures of math. We considered moderation models to examine the interplay of ANS acuity and math anxiety on different aspects of math performance. Math anxiety and ANS acuity were both unique significant predictors of the ability to automatically recall basic number facts. ANS acuity was also a unique significant predictor of the ability to solve applied math problems, and this relation was further qualified by a significant interaction with math anxiety: the positive association between ANS acuity and applied problem solving was only present in students with high math anxiety. Our findings suggest that ANS acuity and math anxiety are differentially related to various aspects of math and should be considered together when examining their respective influences on math ability. Our findings also raise the possibility that good ANS acuity serves as a protective factor for highly math-anxious students on certain types of math assessments. PMID:29718939

  15. When approximate number acuity predicts math performance: The moderating role of math anxiety.

    Science.gov (United States)

    Braham, Emily J; Libertus, Melissa E

    2018-01-01

    Separate lines of research suggest that people who are better at estimating numerical quantities using the approximate number system (ANS) have better math performance, and that people with high levels of math anxiety have worse math performance. Only a handful of studies have examined both ANS acuity and math anxiety in the same participants and those studies report contradictory results. To address these inconsistencies, in the current study 87 undergraduate students completed assessments of ANS acuity, math anxiety, and three different measures of math. We considered moderation models to examine the interplay of ANS acuity and math anxiety on different aspects of math performance. Math anxiety and ANS acuity were both unique significant predictors of the ability to automatically recall basic number facts. ANS acuity was also a unique significant predictor of the ability to solve applied math problems, and this relation was further qualified by a significant interaction with math anxiety: the positive association between ANS acuity and applied problem solving was only present in students with high math anxiety. Our findings suggest that ANS acuity and math anxiety are differentially related to various aspects of math and should be considered together when examining their respective influences on math ability. Our findings also raise the possibility that good ANS acuity serves as a protective factor for highly math-anxious students on certain types of math assessments.

  16. When approximate number acuity predicts math performance: The moderating role of math anxiety.

    Directory of Open Access Journals (Sweden)

    Emily J Braham

    Full Text Available Separate lines of research suggest that people who are better at estimating numerical quantities using the approximate number system (ANS have better math performance, and that people with high levels of math anxiety have worse math performance. Only a handful of studies have examined both ANS acuity and math anxiety in the same participants and those studies report contradictory results. To address these inconsistencies, in the current study 87 undergraduate students completed assessments of ANS acuity, math anxiety, and three different measures of math. We considered moderation models to examine the interplay of ANS acuity and math anxiety on different aspects of math performance. Math anxiety and ANS acuity were both unique significant predictors of the ability to automatically recall basic number facts. ANS acuity was also a unique significant predictor of the ability to solve applied math problems, and this relation was further qualified by a significant interaction with math anxiety: the positive association between ANS acuity and applied problem solving was only present in students with high math anxiety. Our findings suggest that ANS acuity and math anxiety are differentially related to various aspects of math and should be considered together when examining their respective influences on math ability. Our findings also raise the possibility that good ANS acuity serves as a protective factor for highly math-anxious students on certain types of math assessments.

  17. Local and non-local deficits in amblyopia: acuity and spatial interactions.

    Science.gov (United States)

    Bonneh, Yoram S; Sagi, Dov; Polat, Uri

    2004-12-01

    Amblyopic vision is thought to be limited by abnormal long-range spatial interactions, but their exact mode of action and relationship to the main amblyopic deficit in visual acuity is largely unknown. We studied this relationship in a group (N=59) of anisometropic (N=21) and strabismic (or combined, N=38) subjects, using (1) a single and multi-pattern (crowded) computerized static Tumbling-E test with scaled spacing of two pattern widths (TeVA), in addition to an optotype (ETDRS chart) acuity test (VA) and (2) contrast detection of Gabor patches with lateral flankers (lateral masking) along the horizontal and vertical axes as well as in collinear and parallel configurations. By correlating the different measures of visual acuity and contrast suppression, we found that (1) the VA of the strabismic subjects could be decomposed into two uncorrelated components measured in TeVA: acuity for isolated patterns and acuity reduction due to flanking patterns. The latter comprised over 60% of the VA magnitude, on the average and accounted for over 50% of its variance. In contrast, a slight reduction in acuity was found in the anisometropic subjects, and the acuity for a single pattern could account for 70% of the VA variance. (2) The lateral suppression (contrast threshold elevation) in a parallel configuration along the horizontal axis was correlated with the VA (R2=0.7), as well as with the crowding effect (TeVA elevation, R2=0.5) for the strabismic group. Some correlation with the VA was also found for the collinear configuration in the anisometropic group, but less suppression and no correlation were found for all the vertical configurations in all the groups. The results indicate the existence of a specific non-local component of the strabismic deficit, in addition to the local acuity deficit in all amblyopia types. This deficit might reflect long-range lateral inhibition, or alternatively, an inaccurate and scattered top-down attentional selection mechanism.

  18. Does the centre of mass remain stable during complex human postural equilibrium tasks in weightlessness?

    Science.gov (United States)

    Stapley, Paul; Pozzo, Thierry

    In normal gravity conditions the execution of voluntary movement involves the displacement of body segments as well as the maintenance of a stable reference value for equilibrium control. It has been suggested that centre of mass (CM) projection within the supporting base (BS) is the stabilised reference for voluntary action, and is conserved in weightlessness. The purpose of this study was to determine if the CM is stabilised during whole body reaching movements executed in weightlessness. The reaching task was conducted by two cosmonauts aboard the Russian orbital station MIR, during the Franco-Russian mission ALTAIR, 1993. Movements of reflective markers were recorded using a videocamera, successive images being reconstructed by computer every 40ms. The position of the CM, ankle joint torques and shank and thigh angles were computed for each subject pre- in- and post-flight using a 7-link mathematical model. Results showed that both cosmonauts adopted a backward leaning posture prior to reaching movements. Inflight, the CM was displaced throughout values in the horizontal axis three times those of pre-flight measures. In addition, ankle dorsi flexor torques inflight increased to values double those of pre- and post-flight tests. This study concluded that CM displacements do not remain stable during complex postural equilibrium tasks executed in weightlessness. Furthermore, in the absence of gravity, subjects changed their strategy for producing ankle torque during spaceflight from a forward to a backward leaning posture.

  19. Improved Mental Acuity Forecasting with an Individualized Quantitative Sleep Model

    Directory of Open Access Journals (Sweden)

    Brent D. Winslow

    2017-04-01

    Full Text Available Sleep impairment significantly alters human brain structure and cognitive function, but available evidence suggests that adults in developed nations are sleeping less. A growing body of research has sought to use sleep to forecast cognitive performance by modeling the relationship between the two, but has generally focused on vigilance rather than other cognitive constructs affected by sleep, such as reaction time, executive function, and working memory. Previous modeling efforts have also utilized subjective, self-reported sleep durations and were restricted to laboratory environments. In the current effort, we addressed these limitations by employing wearable systems and mobile applications to gather objective sleep information, assess multi-construct cognitive performance, and model/predict changes to mental acuity. Thirty participants were recruited for participation in the study, which lasted 1 week. Using the Fitbit Charge HR and a mobile version of the automated neuropsychological assessment metric called CogGauge, we gathered a series of features and utilized the unified model of performance to predict mental acuity based on sleep records. Our results suggest that individuals poorly rate their sleep duration, supporting the need for objective sleep metrics to model circadian changes to mental acuity. Participant compliance in using the wearable throughout the week and responding to the CogGauge assessments was 80%. Specific biases were identified in temporal metrics across mobile devices and operating systems and were excluded from the mental acuity metric development. Individualized prediction of mental acuity consistently outperformed group modeling. This effort indicates the feasibility of creating an individualized, mobile assessment and prediction of mental acuity, compatible with the majority of current mobile devices.

  20. The Prevalence of Visual Acuity Impairment among School Children at Arada Subcity Primary Schools in Addis Ababa, Ethiopia.

    Science.gov (United States)

    Darge, Haile Fentahun; Shibru, Getahun; Mulugeta, Abiy; Dagnachew, Yinebeb Mezgebu

    2017-01-01

    Visual impairment and blindness are major public health problems in developing countries where there is no enough health-care service. To determine the prevalence of visual impairment among school children. A school-based cross-sectional study was conducted between 15 June 2015 and 30 November 2015 at Arada subcity primary schools, Addis Ababa, Ethiopia. Two schools were selected randomly, and 378 students were screened from grades 1 to 8 using systematic random sampling method. Snellen chart was used for visual acuity test. Students who had visual acuity of ≤6/12 were further examined by an ophthalmologist to diagnose the reason for low vision. Data was analyzed using SPSS version 20. A total of 378 students were screened, and 192 (50.8%) were females and the remaining 186 (49.2%) were males. The prevalence of visual impairment (VA) of ≤6/12 on either eye was 5.8%, VA visual acuity impairment. The prevalence of visual impairment among school children in the study area was 5.8% and school screening is recommended.

  1. P3-4: Binocular Visual Acuity in Exotropia

    Directory of Open Access Journals (Sweden)

    Heekyung Yang

    2012-10-01

    Full Text Available Purpose: To investigate binocular interaction of visual acuity in patients with intermittent exotropia and its relationship with accommodative responses during binocular vision. Methods: Sixty-seven patients with intermittent exotropia of 8 years or older were included. Binocular visual acuity (BVA and monocular visual acuity (MVA were measured in sequence. Accommodative responses of both eyes were measured using the WAM-5500 autorefractor/keratometer (GrandSeiko, Fukuyama, Japan during binocular and monocular viewing conditions at 6 m. Accommodative responses during binocular vision were calculated using the difference between the refractive errors of binocular and monocular vision. Main outcome measures: Binocular interactions of visual acuity were categorized as binocular summation, equivalency, or inhibition. The prevalence of the 3 patterns of binocular interaction was investigated. Accommodative responses were correlated with differences between BVA and better MVA. Results: Most patients (41 patients, 61.2% showed binocular equivalency. Binocular inhibition and summation were noted in 6 (9.0% and 20 (29.9% patients, respectively. Linear regression analysis revealed a significant correlation between binocular interaction and accommodative responses during binocular vision (p < .001. Accommodative responses significantly correlated with the angle of exodeviation at distance (p = .002. Conclusions: In patients with intermittent exotropia, binocular inhibition is associated with increased accommodation and a larger angle of exodeviation, suggesting that accommodative convergence is a mechanism that maintains ocular alignment. Thus, BVA inhibition may be attributed to diminishing fusional control in patients with intermittent exotropia.

  2. The effect of state medicaid case-mix payment on nursing home resident acuity.

    Science.gov (United States)

    Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Mor, Vincent

    2006-08-01

    To examine the relationship between Medicaid case-mix payment and nursing home resident acuity. Longitudinal Minimum Data Set (MDS) resident assessments from 1999 to 2002 and Online Survey Certification and Reporting (OSCAR) data from 1996 to 2002, for all freestanding nursing homes in the 48 contiguous U.S. states. We used a facility fixed-effects model to examine the effect of introducing state case-mix payment on changes in nursing home case-mix acuity. Facility acuity was measured by aggregating the nursing case-mix index (NCMI) from the MDS using the Resource Utilization Group (Version III) resident classification system, separately for new admits and long-stay residents, and by an OSCAR-derived index combining a range of activity of daily living dependencies and special treatment measures. We followed facilities over the study period to create a longitudinal data file based on the MDS and OSCAR, respectively, and linked facilities with longitudinal data on state case-mix payment policies for the same period. Across three acuity measures and two data sources, we found that states shifting to case-mix payment increased nursing home acuity levels over the study period. Specifically, we observed a 2.5 percent increase in the average acuity of new admits and a 1.3 to 1.4 percent increase in the acuity of long-stay residents, following the introduction of case-mix payment. The adoption of case-mix payment increased access to care for higher acuity Medicaid residents.

  3. Perceptual learning improves contrast sensitivity, visual acuity, and foveal crowding in amblyopia.

    Science.gov (United States)

    Barollo, Michele; Contemori, Giulio; Battaglini, Luca; Pavan, Andrea; Casco, Clara

    2017-01-01

    Amblyopic observers present abnormal spatial interactions between a low-contrast sinusoidal target and high-contrast collinear flankers. It has been demonstrated that perceptual learning (PL) can modulate these low-level lateral interactions, resulting in improved visual acuity and contrast sensitivity. We measured the extent and duration of generalization effects to various spatial tasks (i.e., visual acuity, Vernier acuity, and foveal crowding) through PL on the target's contrast detection. Amblyopic observers were trained on a contrast-detection task for a central target (i.e., a Gabor patch) flanked above and below by two high-contrast Gabor patches. The pre- and post-learning tasks included lateral interactions at different target-to-flankers separations (i.e., 2, 3, 4, 8λ) and included a range of spatial frequencies and stimulus durations as well as visual acuity, Vernier acuity, contrast-sensitivity function, and foveal crowding. The results showed that perceptual training reduced the target's contrast-detection thresholds more for the longest target-to-flanker separation (i.e., 8λ). We also found generalization of PL to different stimuli and tasks: contrast sensitivity for both trained and untrained spatial frequencies, visual acuity for Sloan letters, and foveal crowding, and partially for Vernier acuity. Follow-ups after 5-7 months showed not only complete maintenance of PL effects on visual acuity and contrast sensitivity function but also further improvement in these tasks. These results suggest that PL improves facilitatory lateral interactions in amblyopic observers, which usually extend over larger separations than in typical foveal vision. The improvement in these basic visual spatial operations leads to a more efficient capability of performing spatial tasks involving high levels of visual processing, possibly due to the refinement of bottom-up and top-down networks of visual areas.

  4. Efficacy of perceptual vision therapy in enhancing visual acuity and contrast sensitivity function in adult hypermetropic anisometropic amblyopia

    Directory of Open Access Journals (Sweden)

    Yalcin E

    2013-12-01

    Full Text Available Elvan Yalcin, Ozlem BalciWorld Eye Hospital, Department of Pediatric Ophthalmology, Istanbul, TurkeyBackground: The purpose of this study was to evaluate the efficacy of neural vision therapy, also termed perceptual vision therapy, in enhancing best corrected visual acuity (BCVA and contrast sensitivity function in amblyopic patients.Methods: This prospective study enrolled 99 subjects previously diagnosed with unilateral hypermetropic amblyopia aged 9–50 years. The subjects were divided into two groups, with 53 subjects (53 eyes in the perceptual vision therapy group and 46 subjects (46 eyes in the control group. Because the nature of the treatment demands hard work and strict compliance, we enrolled the minimal number of subjects required to achieve statistically significant results. Informed consent was obtained from all subjects. Study phases included a baseline screening, a series of 45 training sessions with perceptual vision therapy, and an end-of-treatment examination. BCVA and contrast sensitivity function at 1.5, 3, 6, 12, and 18 cycles per degree spatial frequencies were obtained for statistical analysis in both groups. All subjects had follow-up examinations within 4–8 months. With the exception of one subject from the study group and two subjects from the control group, all subjects had occlusion during childhood. The study was not masked.Results: The results for the study group demonstrated a mean improvement of 2.6 logarithm of the minimum angle of resolution (logMAR lines in visual acuity (from 0.42 to 0.16 logMAR. Contrast sensitivity function improved at 1.5, 3, 6, 12, and 18 cycles per degree spatial frequencies. The control group did not show any significant change in visual acuity or contrast sensitivity function. None of the treated eyes showed a drop in visual acuity. Manifest refractions remained unchanged during the study.Conclusion: The results of our study demonstrate the efficacy of perceptual vision therapy in

  5. Visual Acuity does not Moderate Effect Sizes of Higher-Level Cognitive Tasks

    Science.gov (United States)

    Houston, James R.; Bennett, Ilana J.; Allen, Philip A.; Madden, David J.

    2016-01-01

    Background Declining visual capacities in older adults have been posited as a driving force behind adult age differences in higher-order cognitive functions (e.g., the “common cause” hypothesis of Lindenberger & Baltes, 1994). McGowan, Patterson and Jordan (2013) also found that a surprisingly large number of published cognitive aging studies failed to include adequate measures of visual acuity. However, a recent meta-analysis of three studies (LaFleur & Salthouse, 2014) failed to find evidence that visual acuity moderated or mediated age differences in higher-level cognitive processes. In order to provide a more extensive test of whether visual acuity moderates age differences in higher-level cognitive processes, we conducted a more extensive meta-analysis of topic. Methods Using results from 456 studies, we calculated effect sizes for the main effect of age across four cognitive domains (attention, executive function, memory, and perception/language) separately for five levels of visual acuity criteria (no criteria, undisclosed criteria, self-reported acuity, 20/80-20/31, and 20/30 or better). Results As expected, age had a significant effect on each cognitive domain. However, these age effects did not further differ as a function of visual acuity criteria. Conclusion The current meta-analytic, cross-sectional results suggest that visual acuity is not significantly related to age group differences in higher-level cognitive performance—thereby replicating LaFleur and Salthouse (2014). Further efforts are needed to determine whether other measures of visual functioning (e.g. contrast sensitivity, luminance) affect age differences in cognitive functioning. PMID:27070044

  6. Impact of contamination and pre-treatment on stable carbon and nitrogen isotopic composition of charred plant remains.

    Science.gov (United States)

    Vaiglova, Petra; Snoeck, Christophe; Nitsch, Erika; Bogaard, Amy; Lee-Thorp, Julia

    2014-12-15

    Stable isotope analysis of archaeological charred plants has become a useful tool for interpreting past agricultural practices and refining ancient dietary reconstruction. Charred material that lay buried in soil for millennia, however, is susceptible to various kinds of contamination, whose impact on the grain/seed isotopic composition is poorly understood. Pre-treatment protocols have been adapted in distinct forms from radiocarbon dating, but insufficient research has been carried out on evaluating their effectiveness and necessity for stable carbon and nitrogen isotope analysis. The effects of previously used pre-treatment protocols on the isotopic composition of archaeological and modern sets of samples were investigated. An archaeological sample was also artificially contaminated with carbonates, nitrates and humic acid and subjected to treatment aimed at removing the introduced contamination. The presence and removal of the contamination were investigated using Fourier transform infrared spectroscopy (FTIR) and δ(13)C and δ(15)N values. The results show a ca 1‰ decrease in the δ(15)N values of archaeological charred plant material caused by harsh acid treatments and ultra-sonication. This change is interpreted as being caused by mechanical distortion of the grains/seeds rather than by the removal of contamination. Furthermore, specific infrared peaks have been identified that can be used to detect the three types of contaminants studied. We argue that it is not necessary to try to remove humic acid contamination for stable isotope analysis. The advantages and disadvantages of crushing the grains/seeds before pre-treatment are discussed. We recommend the use of an acid-only procedure (0.5 M HCl for 30 min at 80 °C followed by three rinses in distilled water) for cleaning charred plant remains. This study fills an important gap in plant stable isotope research that will enable future researchers to evaluate potential sources of isotopic change and pre

  7. Female carpet weavers' visual acuity and effective factors: Fordu rural area of Qom

    Directory of Open Access Journals (Sweden)

    Khajenasiri F.

    2007-11-01

    Full Text Available Background: Healthy vision of workers is one of the important elements in carpet weaving industry which has essential role in improving of the job quality and efficiency. Visual acuity is the primary outcome measure in most studies involving eye diseases. Ihe aim of this study was determination of visual acuity and its effective factors in women carpet weaver in fordu rural area of Qom has been investigated.  Methods: In a cross-sectional (descriptive-analytical study visual acuity of 177 women carpet weaver has been determined. Job hours per day, job history, age, literacy, trauma history, diabetes history, family history of eye diseases, eye diseases history and family size  of subjects were determined .Results: The results of study indicated that the right eyes visual acuity of 72.4 % of women were desirable (0 - 0.8 and 27.6 % were undesirable (0.9-1.2. These results for the left eyes were 69.5 % and 30.5 % respectively. In addition, the result showed that with increasing the job hours and history and age, percent of women with undesirable both eyes visual acuity were increased. With higher literacy levels, percent of women with undesirable both eyes visual acuity decreased. In subjects with truma history, the undesirable visual acuity was higher. In this study the relation between visual acuity and job history, age, literacy, truma history and eye diseases history were statistically significant (in all cases P<0.05.Conclusions: High percentage of women carpet weaver were in undesirable  visual acuity and in this study the relation between visual acuity and job history, age, literacy, trauma history and eye diseases history were statistically significant (in all cases P<0.05.

  8. Variable acuity remote viewing system flight demonstration

    Science.gov (United States)

    Fisher, R. W.

    1983-01-01

    The Variable Acuity Remote Viewing System (VARVS), originally developed under contract to the Navy (ONR) as a laboratory brassboard, was modified for flight demonstration. The VARVS system was originally conceived as a technique which could circumvent the acuity/field of view/bandwidth tradeoffs that exists in remote viewing to provide a nearly eye limited display in both field of view (160 deg) and resolution (2 min arc) while utilizing conventional TV sensing, transmission, and display equipment. The modifications for flight demonstration consisted of modifying the sensor so it could be installed and flow in a Piper PA20 aircraft, equipped for remote control and modifying the display equipment so it could be integrated with the NASA Research RPB (RPRV) remote control cockpit.

  9. Visual acuity outcomes in eyes with flat corneas after PRK.

    Science.gov (United States)

    Varssano, David; Waisbourd, Michael; Minkev, Liza; Sela, Tzahi; Neudorfer, Meira; Binder, Perry S

    2013-06-01

    To evaluate the impact of corneal curvatures less than 35 diopters (D) after photorefractive keratectomy (PRK) on visual acuity outcomes. Visual acuity outcomes of 5,410 eyes that underwent PRK from January 2006 to November 2010 were retrospectively analyzed for the impact of postoperative corneal curvatures on visual outcomes. All procedures were performed on a single platform (Allegretto 200Hz excimer laser; Alcon Laboratories, Inc., Irvine, CA). Main outcome measures were postoperative corrected distance visual acuity (CDVA) and loss of CDVA. Corneas with a measured or a calculated postoperative flat meridian less than 35 D and those with a measured postoperative steep meridian less than 35 D had worse postoperative CDVA than corneas with meridians of either 35 D or more (P ≤ .021). However, the preoperative CDVA was worse in the flatter curvatures in all comparisons performed (P ≤ .024). Consequently, the measured or calculated meridian curvature had no effect on CDVA loss (P ≥ .074). Postoperative corneal keratometry values (flat and steep meridians) less than 35 D did not have a predictive effect on the risk of losing visual acuity following myopic PRK performed on the Allegretto 200Hz excimer laser. Copyright 2013, SLACK Incorporated.

  10. Should we add visual acuity ratios to referral criteria for potential cerebral visual impairment?

    Science.gov (United States)

    van der Zee, Ymie J; Stiers, Peter; Evenhuis, Heleen M

    To determine whether the assessment of visual acuity ratios might improve the referral of children with (sub)normal visual acuity but at risk of cerebral visual impairment. In an exploratory study, we assessed visual acuity, crowding ratio and the ratios between grating acuity (Teller Acuity Cards-II) and optotype acuity (Cambridge Crowding Cards) in 60 typically developing school children (mean age 5y8m±1y1m), 21 children with ocular abnormalities only (5y7m±1y9m) and 26 children with (suspected) brain damage (5y7m±1y11m). Sensitivities and specificities were calculated for targets and controls from the perspective of different groups of diagnosticians: youth health care professionals (target: children with any visual abnormalities), ophthalmologists and low vision experts (target: children at risk of cerebral visual impairment). For youth health care professionals subnormal visual acuity had the best sensitivity (76%) and specificity (70%). For ophthalmologists and low vision experts the crowding ratio had the best sensitivity (67%) and specificity (79 and 86%). Youth health care professionals best continue applying subnormal visual acuity for screening, whereas ophthalmologists and low vision experts best add the crowding ratio to their routine diagnostics, to distinguish children at risk of visual impairment in the context of brain damage from children with ocular pathology only. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  11. Out of sight, out of mind? Relations between visual acuity and cognition.

    Science.gov (United States)

    La Fleur, Claire G; Salthouse, Timothy A

    2014-10-01

    Prior research has established significant relations between measures of sensory ability and cognitive function in adults of different ages, and several explanations for this relation have been proposed. One explanation is that sensory abilities restrict cognitive processing, a second is that cognitive abilities influence assessments of sensory ability, and a third is that both sensory function and cognition are affected by a common, potentially age-based, third factor. These explanations were investigated using mediation and moderation analyses, with near visual acuity as the sensory measure and scores on visual speed tests and auditory memory tests as the cognitive measures. Measures of visual acuity, speed, and memory were obtained from three moderately large samples, two cross-sectional (N = 380, N = 4,779) and one longitudinal (N = 2,258), with participants ranging from 18 to 90 years of age. The visual acuity and cognitive measures had different age trajectories, and the visual acuity-cognition relations were similar in each 5-year age band. The results suggest that the age-related differences and changes in near visual acuity are unlikely to contribute to the age-related differences and changes in speed and memory measures.

  12. Acuity-adaptable nursing care: exploring its place in designing the future patient room.

    Science.gov (United States)

    Kwan, Melissa A

    2011-01-01

    To substantiate the anticipated benefits of the original acuity-adaptable care delivery model as defined by innovator Ann Hendrich. In today's conveyor belt approach to healthcare, upon admission and through discharge, patients are commonly transferred based on changing acuity needs. Wasted time and money and inefficiencies in hospital operations often result-in addition to jeopardizing patient safety. In the last decade, a handful of hospitals pioneered the implementation of the acuity-adaptable care delivery model. Built on the concept of eliminating patient transfers, the projected outcomes of acuity-adaptable units-decreased average lengths of stay, increased patient safety and satisfaction, and increased nurses' satisfaction from reduced walking distances-make a good case for a model patient room. Although some hospitals experienced the projected benefits of the acuity-adaptable care delivery model, sustaining the outcomes proved to be difficult; hence, the original definition of acuity-adaptable units has not fared well. Variations on the original concept demonstrate that eliminating patient transfers has not been completely abandoned in healthcare redesign and construction initiatives. Terms such as flex-up, flex-down, universal room, and single-stay unit have since emerged. These variations convolute the search for empirical evidence to support the anticipated benefits of the original concept. To determine the future of this concept and its variants, a significant amount of outcome data must be generated by piloting the concept in different hospital settings. As further refinements and adjustments to the concept emerge, the acuity-adaptable room may find a place in future hospitals.

  13. Visual Acuity Testing: Feedback Affects Neither Outcome nor Reproducibility, but Leaves Participants Happier.

    Science.gov (United States)

    Bach, Michael; Schäfer, Kerstin

    2016-01-01

    Assessment of visual acuity is a well standardized procedure at least for expert opinions and clinical trials. It is often recommended not giving patients feedback on the correctness of their responses. As this viewpoint has not been quantitatively examined so far, we quantitatively assessed possible effects of feedback on visual acuity testing. In 40 normal participants we presented Landolt Cs in 8 orientations using the automated Freiburg Acuity Test (FrACT, feedback was provided in 2 x 4 conditions: (A) no feedback, (B) acoustic signals indicating correctness, (C)visual indication of correct orientation, and (D) a combination of (B) and (C). After each run the participants judged comfort. Main outcome measures were absolute visual acuity (logMAR), its test-retest agreement (limits of agreement) and participants' comfort estimates on a 5-step symmetric Likert scale. Feedback influenced acuity outcome significantly (p = 0.02), but with a tiny effect size: 0.02 logMAR poorer acuity for (D) compared to (A), even weaker effects for (B) and (C). Test-retest agreement was high (limits of agreement: ± 1.0 lines) and did not depend on feedback (p>0.5). The comfort ranking clearly differed, by 2 steps on the Likert scale: the condition (A)-no feedback-was on average "slightly uncomfortable", the other three conditions were "slightly comfortable" (pFeedback affected neither reproducibility nor the acuity outcome to any relevant extent. The participants, however, reported markedly greater comfort with any kind of feedback. We conclude that systematic feedback (as implemented in FrACT) offers nothing but advantages for routine use.

  14. Visual Acuity Improvement in Continuous vs Divided Occlusion in Anisometropic Amblyopia.

    Science.gov (United States)

    Irfani, Irawati; Feriyanto, Feri; Oktarima, Primawita; Kartasasmita, Arief

    2018-01-01

    To compare visual acuity improvement between continuous and split part-time occlusion for the treatment of moderate and severe anisometropic amblyopia. Randomised clinical trials in 6 - 13 y.o children with moderate and severe anisometropic amblyopia. Each patient was consecutively selected with continuous or split part-time occlusion. Best corrected visual acuity's improvement was followed up to six weeks and statistical data were analyzed using chi square and unpaired t-test. Best corrected visual acuity's improvement was comparable between continuous and split part-time occlusion (0.20±0.27 vs 0.21±0.25; p = 0.79). Split part-time occlusion may be considered as an alternative treatment for moderate and severe anisometropic amblyopia treatment.

  15. Measuring the Influence of Galilean Loupe System on Near Visual Acuity of Dentists under Simulated Clinical Conditions

    Directory of Open Access Journals (Sweden)

    Iris Urlić

    2016-01-01

    Full Text Available Aim: The purpose of this study was to compare near visual acuity of dentists without optical aids (VSC with near visual acuity of those using the Galilean telescope system (VGA2 with magnification of x 2.5, and the distance of 350 mm in simulated clinical conditions. Methods: The study included 46 dentists (visual acuity 1.0 without correction. A visual acuity testing was carried out using a miniaturized Snellen visual acuity chart which was placed in the cavity of molar teeth mounted in a phantom head in simulated clinical conditions. Near visual acuity for the vicinity was examined: 1 without correction at a distance of 300-400 mm (VSC; 2 with Galilean loupes with magnification of x2.5, focal length of 350mm. Results: The distributions of near visual acuity recorded using VSC and VGA2, 5 systems were compared by the Wilcoxon Signed Rank test. The results obtained by Wilcoxon Signed Rank test pointed to a statistically significant difference in the distribution of recorded visual acuity between the VSC and VGA2 optical systems (W = - 403.5; p <0.001. Conclusion: If using the VGA2, 5 systems, higher values of the near visual acuity were recorded and subsequently compared to near visual acuity without magnifying aids (VSC.

  16. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  17. Role of stable isotope analyses in reconstructing past life-histories and the provenancing human skeletal remains: a review

    Directory of Open Access Journals (Sweden)

    Sehrawat Jagmahender Singh

    2017-09-01

    Full Text Available This article reviews the present scenario of use of stable isotopes (mainly δ13C, δ15N, δ18O, 87Sr to trace past life behaviours like breast feeding and weaning practices, the geographic origin, migration history, paleodiet and subsistence patterns of past populations from the chemical signatures of isotopes imprinted in human skeletal remains. This approach is based on the state that food-web isotopic signatures are seen in the human bones and teeth and such signatures can change parallely with a variety of biogeochemical processes. By measuring δ13C and δ15N isotopic values of subadult tissues of different ages, the level of breast milk ingestion at particular ages and the components of the complementary foods can be assessed. Strontium and oxygen isotopic analyses have been used for determining the geographic origins and reconstructing the way of life of past populations as these isotopes can map the isotopic outline of the area from where the person acquired water and food during initial lifetime. The isotopic values of strontium and oxygen values are considered specific to geographical areas and serve as reliable chemical signatures of migration history of past human populations (local or non-local to the site. Previous isotopic studies show that the subsistence patterns of the past human populations underwent extensive changes from nomadic to complete agricultural dependence strategies. The carbon and nitrogen isotopic values of local fauna of any archaeological site can be used to elucidate the prominence of freshwater resources in the diet of the past human populations found near the site. More extensive research covering isotopic descriptions of various prehistoric, historic and modern populations is needed to explore the role of stable isotope analysis for provenancing human skeletal remains and assessing human migration patterns/routes, geographic origins, paleodiet and subsistence practices of past populations.

  18. ANS acuity and mathematics ability in preschoolers from low-income homes: contributions of inhibitory control.

    Science.gov (United States)

    Fuhs, Mary Wagner; McNeil, Nicole M

    2013-01-01

    Recent findings by Libertus, Feigenson, and Halberda (2011) suggest that there is an association between the acuity of young children's approximate number system (ANS) and their mathematics ability before exposure to instruction in formal schooling. The present study examined the generalizability and validity of these findings in a sample of preschoolers from low-income homes. Children attending Head Start (N = 103) completed measures to assess ANS acuity, mathematics ability, receptive vocabulary, and inhibitory control. Results showed only a weak association between ANS acuity and mathematics ability that was reduced to non-significance when controlling for a direct measure of receptive vocabulary. Results also revealed that inhibitory control plays an important role in the relation between ANS acuity and mathematics ability. Specifically, ANS acuity accounted for significant variance in mathematics ability over and above receptive vocabulary, but only for ANS acuity trials in which surface area conflicted with numerosity. Moreover, this association became non-significant when controlling for inhibitory control. These results suggest that early mathematical experiences prior to formal schooling may influence the strength of the association between ANS acuity and mathematics ability and that inhibitory control may drive that association in young children. © 2012 Blackwell Publishing Ltd.

  19. Visual acuity in adults with Asperger's syndrome: no evidence for "eagle-eyed" vision.

    Science.gov (United States)

    Falkmer, Marita; Stuart, Geoffrey W; Danielsson, Henrik; Bram, Staffan; Lönebrink, Mikael; Falkmer, Torbjörn

    2011-11-01

    Autism spectrum conditions (ASC) are defined by criteria comprising impairments in social interaction and communication. Altered visual perception is one possible and often discussed cause of difficulties in social interaction and social communication. Recently, Ashwin et al. suggested that enhanced ability in local visual processing in ASC was due to superior visual acuity, but that study has been the subject of methodological criticism, placing the findings in doubt. The present study investigated visual acuity thresholds in 24 adults with Asperger's syndrome and compared their results with 25 control subjects with the 2 Meter 2000 Series Revised ETDRS Chart. The distribution of visual acuities within the two groups was highly similar, and none of the participants had superior visual acuity. Superior visual acuity in individuals with Asperger's syndrome could not be established, suggesting that differences in visual perception in ASC are not explained by this factor. A continued search for explanations of superior ability in local visual processing in persons with ASC is therefore warranted. Copyright © 2011 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  20. How to measure distance visual acuity

    Directory of Open Access Journals (Sweden)

    Janet Marsden

    2014-04-01

    Full Text Available Visual acuity (VA is a measure of the ability of the eye to distinguish shapes and the details of objects at a given distance. It is important to assess VA in a consistent way in order to detect any changes in vision. One eye is tested at a time.

  1. [Dice test--a simple method for assessment of visual acuity in infants with visual deficits].

    Science.gov (United States)

    Rohrschneider, K; Brill, B; Bayer, Y; Ahrens, P

    2010-07-01

    Determination of visual acuity in low vision infants or patients with additional cerebral retardation is difficult. In our low vision department we used dice of different sizes and colors as well as other defined objects to determine visual acuity (VA). In this study we compared the results of the dice test with conventional tests for measurement of visual acuity. A total of 88 children with different causes of visual impairment e.g. albinism, retinal scars, retinopathy of prematurity (ROP), achromatopsia and optic atrophy etc., were included in this longitudinal study. Median follow-up time was 8.7 years (range 2.9-18.9 years). The first reliable examination was performed between the ages of 4 and 24 months (median 11 months). We estimated VA depending on the edge length of the dice, which were recognized at a distance of 30 cm, while 4 mm complied with VA 20/200. Best corrected binocular visual acuity was compared between the dice test, measurement with the Lea symbols and with numbers or Landolt rings. Estimation of visual acuity using the dice test was possible at the end of the first year of life (median 11 months, range 4-27 months). Although observation is limited to visual acuity results in the low vision range between light reaction and 20/120 there was nearly complete agreement between all three VA measurements. Visual acuity ranged from light perception to 20/20 with a median of 20/100. In 39 patients visual acuity was 20/200 or less at the end of the observation period. Visual acuity estimation overestimated visual acuity only in 5 out of the 88 patients, while in all of the patients with later acuity measurements better than 20/200, our best value of 20/200 was achieved. Using simple visual objects, such as dice with different colors and size down to an edge length of 4 mm, it is possible to estimate visual acuity in low vision infants within the first year of life. This option is also very helpful in patients who are not able to perform other visual

  2. Desktop publishing and validation of custom near visual acuity charts.

    Science.gov (United States)

    Marran, Lynn; Liu, Lei; Lau, George

    2008-11-01

    Customized visual acuity (VA) assessment is an important part of basic and clinical vision research. Desktop computer based distance VA measurements have been utilized, and shown to be accurate and reliable, but computer based near VA measurements have not been attempted, mainly due to the limited spatial resolution of computer monitors. In this paper, we demonstrate how to use desktop publishing to create printed custom near VA charts. We created a set of six near VA charts in a logarithmic progression, 20/20 through 20/63, with multiple lines of the same acuity level, different letter arrangements in each line and a random noise background. This design allowed repeated measures of subjective accommodative amplitude without the potential artifact of familiarity of the optotypes. The background maintained a constant and spatial frequency rich peripheral stimulus for accommodation across the six different acuity levels. The paper describes in detail how pixel-wise accurate black and white bitmaps of Sloan optotypes were used to create the printed custom VA charts. At all acuity levels, the physical sizes of the printed custom optotypes deviated no more than 0.034 log units from that of the standard, satisfying the 0.05 log unit ISO criterion we used to demonstrate physical equivalence. Also, at all acuity levels, log unit differences in the mean target distance for which reliable recognition of letters first occurred for the printed custom optotypes compared to the standard were found to be below 0.05, satisfying the 0.05 log unit ISO criterion we used to demonstrate functional equivalence. It is possible to use desktop publishing to create custom near VA charts that are physically and functionally equivalent to standard VA charts produced by a commercial printing process.

  3. Effect of Target Location on Dynamic Visual Acuity During Passive Horizontal Rotation

    Science.gov (United States)

    Appelbaum, Meghan; DeDios, Yiri; Kulecz, Walter; Peters, Brian; Wood, Scott

    2010-01-01

    The vestibulo-ocular reflex (VOR) generates eye rotation to compensate for potential retinal slip in the specific plane of head movement. Dynamic visual acuity (DVA) has been utilized as a functional measure of the VOR. The purpose of this study was to examine changes in accuracy and reaction time when performing a DVA task with targets offset from the plane of rotation, e.g. offset vertically during horizontal rotation. Visual acuity was measured in 12 healthy subjects as they moved a hand-held joystick to indicate the orientation of a computer-generated Landolt C "as quickly and accurately as possible." Acuity thresholds were established with optotypes presented centrally on a wall-mounted LCD screen at 1.3 m distance, first without motion (static condition) and then while oscillating at 0.8 Hz (DVA, peak velocity 60 deg/s). The effect of target location was then measured during horizontal rotation with the optotypes randomly presented in one of nine different locations on the screen (offset up to 10 deg). The optotype size (logMar 0, 0.2 or 0.4, corresponding to Snellen range 20/20 to 20/50) and presentation duration (150, 300 and 450 ms) were counter-balanced across five trials, each utilizing horizontal rotation at 0.8 Hz. Dynamic acuity was reduced relative to static acuity in 7 of 12 subjects by one step size. During the random target trials, both accuracy and reaction time improved proportional to optotype size. Accuracy and reaction time also improved between 150 ms and 300 ms presentation durations. The main finding was that both accuracy and reaction time varied as a function of target location, with greater performance decrements when acquiring vertical targets. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of motion. Both reaction time and accuracy are functionally relevant DVA parameters of VOR function.

  4. Recognition versus Resolution: a Comparison of Visual Acuity Results Using Two Alternative Test Chart Optotype

    Science.gov (United States)

    Pointer, Jonathan S.

    2010-01-01

    Purpose To quantify the difference between recognition (letter) and resolution (Landolt) visual acuity (VA) in a group of normally sighted subjects. Is it reasonable to assume that the two acuity measures are clinically equivalent? Methods A pair of 6 m acuity test charts was produced: one comprised letters and the other Landolt broken rings. Construction of both charts conformed to the logMAR design format. Monocular VA was determined for the dominant eye of 300 screened and normally sighted optometric patients aged 16 to 40, each wearing an optical refractive (spectacle) correction. Results Letter acuity was superior to Landolt acuity (P≤0.0001). The mean paired acuity difference was -0.041 logMAR (standard deviation 0.034): the 95% limits of agreement were ±0.067 logMAR units or ±3.3 chart optotype. Repeatability was high and similar for each chart type (±2.1 and ±2.4 optotype for letter and Landolt, respectively). Gender, test sequence, and laterality of the dominant eye (left or right) were each non-statistically significant variables. Conclusions For normally sighted subjects wearing an optimal refractive correction, a bias was recorded in favour of recognition over resolution acuity: the clinical difference amounted to approximately 40% of one logMAR chart line, with similar high repeatability for either chart optotype. We conclude that the assumption of clinical equivalence between letter and Landolt acuity is reasonable under optimum test conditions.

  5. The Auckland Optotypes: An open-access pictogram set for measuring recognition acuity.

    Science.gov (United States)

    Hamm, Lisa M; Yeoman, Janice P; Anstice, Nicola; Dakin, Steven C

    2018-03-01

    When measuring recognition acuity in a research setting, the most widely used symbols are the Early Treatment of Diabetic Retinopathy Study (ETDRS) set of 10 Sloan letters. However, the symbols are not appropriate for patients unfamiliar with letters, and acuity for individual letters is variable. Alternative pictogram sets are available, but are generally comprised of fewer items. We set out to develop an open-access set of 10 pictograms that would elicit more consistent estimates of acuity across items than the ETDRS letters from visually normal adults. We measured monocular acuity for individual uncrowded optotypes within a newly designed set (The Auckland Optotype [TAO]), the ETDRS set, and Landolt Cs. Eleven visually normal adults were assessed on regular and vanishing formats of each set. Inter-optotype reliability and ability to detect subtle differences between participants were assessed using intraclass correlations (ICC) and fractional rank precision (FRP). The TAO vanishing set showed the strongest performance (ICC = 0.97, FRP = 0.90), followed by the other vanishing sets (Sloan ICC = 0.88, FRP = 0.74; Landolt ICC = 0.86, FRP = 0.80). Within the regular format, TAO again outperformed the existing sets (TAO ICC = 0.77, FRP = 0.75; Sloan ICC = 0.65, FRP = 0.64; Landolt ICC = 0.48, FRP = 0.63). For adults with normal visual acuity, the new optotypes (in both regular and vanishing formats) are more equally legible and sensitive to subtle individual differences than their Sloan counterparts. As this set does not require observers to be able to name Roman letters, and is freely available to use and modify, it may have wide application for measurement of acuity.

  6. RETENTION OF HIGH TACTILE ACUITY THROUGHOUT THE LIFESPAN IN BLINDNESS

    OpenAIRE

    Legge, Gordon E.; Madison, Cindee; Vaughn, Brenna N.; Cheong, Allen M.Y.; Miller, Joseph C.

    2008-01-01

    Previous studies of tactile acuity on the fingertip using passive touch have demonstrated an age-related decline in spatial resolution for both sighted and blind subjects. We have re-examined this age dependence with two newly designed tactile-acuity charts requiring active exploration of the test symbols. One chart used dot patterns similar to Braille and the other used embossed Landolt rings. Groups of blind Braille readers and sighted subjects, ranging in age from 12 to 85 years, were test...

  7. Buccal mucosal cancer patient who failed to recover taste acuity after partial oral cavity irradiation

    International Nuclear Information System (INIS)

    Saito, Tsutomu; Fukushima, Shoko; Furuhashi, Satoru; Yoshinobu, Takashi; Takahashi, Motoichiro; Miyake, Masahiko; Kawamori, Jiro; Tanaka, Yoshiaki

    2002-01-01

    We report a patient who suffered from prolonged loss of taste acuity after partial oral cavity irradiation. The electric taste threshold (ETT) of each point in the oral cavity was measured with an electric gustometer to evaluate quantitative local taste acuity. A subjective total taste acuity (STTA) scale was used to evaluate subjective total taste acuity. A 61-year-old male patient with right buccal mucosal cancer underwent radiation therapy more than 11 years ago, and has suffered from loss of taste acuity since then. He received electron beam irradiation to part of the oral cavity and right upper neck, mainly the right buccal mucosa near the retromolar trigone and a metastatic right submandibular node. He did not receive irradiation to the anterior portion of the tongue or left side of the posterior portion of the tongue. His ETT scores for each point were equal to or greater than 26, and his STTA score was grade 3. The present case implies that radiation damage to part of the oral cavity can cause the loss of subjective total taste acuity. (author)

  8. Buccal mucosal cancer patient who failed to recover taste acuity after partial oral cavity irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Tsutomu; Fukushima, Shoko; Furuhashi, Satoru; Yoshinobu, Takashi; Takahashi, Motoichiro [Nihon Univ., Tokyo (Japan). Surugadai Hospital; Miyake, Masahiko [Nihon Univ., Tokyo (Japan). School of Dentistry; Kawamori, Jiro; Tanaka, Yoshiaki [Nihon Univ., Tokyo (Japan). School of Medicine

    2002-10-01

    We report a patient who suffered from prolonged loss of taste acuity after partial oral cavity irradiation. The electric taste threshold (ETT) of each point in the oral cavity was measured with an electric gustometer to evaluate quantitative local taste acuity. A subjective total taste acuity (STTA) scale was used to evaluate subjective total taste acuity. A 61-year-old male patient with right buccal mucosal cancer underwent radiation therapy more than 11 years ago, and has suffered from loss of taste acuity since then. He received electron beam irradiation to part of the oral cavity and right upper neck, mainly the right buccal mucosa near the retromolar trigone and a metastatic right submandibular node. He did not receive irradiation to the anterior portion of the tongue or left side of the posterior portion of the tongue. His ETT scores for each point were equal to or greater than 26, and his STTA score was grade 3. The present case implies that radiation damage to part of the oral cavity can cause the loss of subjective total taste acuity. (author)

  9. Tactile acuity and lumbopelvic motor control in patients with back pain and healthy controls.

    Science.gov (United States)

    Luomajoki, H; Moseley, G L

    2011-04-01

    Voluntary lumbopelvic control is compromised in patients with back pain. Loss of proprioceptive acuity is one contributor to decreased control. Several reasons for decreased proprioceptive acuity have been proposed, but the integrity of cortical body maps has been overlooked. We investigated whether tactile acuity, a clear clinical signature of primary sensory cortex organisation, relates to lumbopelvic control in people with back pain. Forty-five patients with back pain and 45 age- and sex-matched healthy controls participated in this cross-sectional study. Tactile acuity at the back was assessed using two-point discrimination (TPD) threshold in vertical and horizontal directions. Voluntary motor control was assessed using an established battery of clinical tests. Patients performed worse on the voluntary lumbopelvic tasks than healthy controls did (p<0.001). TPD threshold was larger in patients (mean (SD)=61 (13) mm) than in healthy controls (44 (10) mm). Moreover, larger TPD threshold was positively related to worse performance on the voluntary lumbopelvic tasks (Pearson's r=0.49; p<0.001). Tactile acuity, a clear clinical signature of primary sensory cortex organisation, relates to voluntary lumbopelvic control. This relationship raises the possibility that the former contributes to the latter, in which case training tactile acuity may aid recovery and assist in achieving normal motor performance after back injury.

  10. Wavefront coherence area for predicting visual acuity of post-PRK and post-PARK refractive surgery patients

    Science.gov (United States)

    Garcia, Daniel D.; van de Pol, Corina; Barsky, Brian A.; Klein, Stanley A.

    1999-06-01

    Many current corneal topography instruments (called videokeratographs) provide an `acuity index' based on corneal smoothness to analyze expected visual acuity. However, post-refractive surgery patients often exhibit better acuity than is predicted by such indices. One reason for this is that visual acuity may not necessarily be determined by overall corneal smoothness but rather by having some part of the cornea able to focus light coherently onto the fovea. We present a new method of representing visual acuity by measuring the wavefront aberration, using principles from both ray and wave optics. For each point P on the cornea, we measure the size of the associated coherence area whose optical path length (OPL), from a reference plane to P's focus, is within a certain tolerance of the OPL for P. We measured the topographies and vision of 62 eyes of patients who had undergone the corneal refractive surgery procedures of photorefractive keratectomy (PRK) and photorefractive astigmatic keratectomy (PARK). In addition to high contrast visual acuity, our vision tests included low contrast and low luminance to test the contribution of the PRK transition zone. We found our metric for visual acuity to be better than all other metrics at predicting the acuity of low contrast and low luminance. However, high contrast visual acuity was poorly predicted by all of the indices we studied, including our own. The indices provided by current videokeratographs sometimes fail for corneas whose shape differs from simple ellipsoidal models. This is the case with post-PRK and post-PARK refractive surgery patients. Our alternative representation that displays the coherence area of the wavefront has considerable advantages, and promises to be a better predictor of low contrast and low luminance visual acuity than current shape measures.

  11. Radiation-induced changes in taste acuity in cancer patients

    International Nuclear Information System (INIS)

    Mossman, K.L.; Henkin, R.I.

    1978-01-01

    Changes in taste acuity were measured in 27 patients with various forms of cancer who received radiation to the head and neck region. In 9 of these patients (group I), measurements of taste acuity were made more than 1 year after completion of radiation therapy. In the other 18 patients (group II), taste measurements were made before, during, and approximately 1 month after radiation therapy. Taste acuity was measured for four taste qualities (salt, sweet, sour, and bitter) by a forced choice-three stimulus drop technique which measured detection and recognition thresholds and by a forced scaling technique which measured taste intensity responsiveness. In group II patients, impaired acuity, as indicated by elevated detection and recognition thresholds, was observed approximately 3 weeks after initiation of radiotherapy. The bitter and salt qualities showed the earliest and greatest impairment and the sweet quality the least. Taste intensity responsiveness also was impaired in group II patients. As for thresholds, scaling impairment was most severe for bitter and salt taste qualities. Scaling impairment occurred before changes in either detection or recognition thresholds. Detection and recognition thresholds determined in group I patients also showed salt and bitter qualities were affected more severely than either sweet or sour qualities. Zinc administration to group I patients in an uncontrolled study suggested that zinc therapy may be useful in ameliorating taste impairment in some patients. These results suggest that taste loss may be a factor in the anorexia and weight loss that is observed commonly in patients who have undergone radiation treatment. Correction of this abnormality may be useful in aiding the nutritional status of these patients

  12. Analysis of relationship among visual evoked potential, oscillatory potential and visual acuity under stimulated weightlessness

    Directory of Open Access Journals (Sweden)

    Jun Zhao

    2013-05-01

    Full Text Available AIM: To observe the influence of head-down tilt simulated weightlessness on visual evoked potential(VEP, oscillatory potentials(OPsand visual acuity, and analyse the relationship among them. METHODS: Head-down tilt for -6° was adopted in 14 healthy volunteers. Distant visual acuity, near visual acuity, VEP and OPs were recorded before, two days and five days after trial. The record procedure of OPs followed the ISCEV standard for full-field clinical electroretinography(2008 update. RESULTS: Significant differences were detected in the amplitude of P100 waves and ∑OPs among various time points(P<0.05. But no relationship was observed among VEP, OPs and visual acuity. CONCLUSION: Head-down tilt simulated weightlessness induce the rearrange of blood of the whole body including eyes, which can make the change of visual electrophysiology but not visual acuity.

  13. Visual acuity and associated factors. The Central India Eye and Medical Study.

    Directory of Open Access Journals (Sweden)

    Vinay Nangia

    Full Text Available Visual acuity is a major parameter for quality of vision and quality of life. Information on visual acuity and its associated factors in rural societies almost untouched by any industrialization is mostly non-available. It was, therefore, the purpose of our study to determine the distribution of visual acuity and its associated factors in a rural population not marked influenced by modern lifestyle. The population-based Central India Eye and Medical Study included 4711 subjects (aged 30+ years, who underwent a detailed ophthalmologic examination including visual acuity measurement. Visual acuity measurements were available for 4706 subjects with a mean age of 49.5±13.4 years (range: 30-100 years. BCVA decreased significantly (P<0.001 from the moderately hyperopic group (0.08±0.15 logMAR to the emmetropic group (0.16±0.52 logMAR, the moderately myopic group (0.28±0.33 logMAR, the highly hyperopic group (0.66±0.62 logMAR and finally the highly myopic group (1.32±0.92 logMAR. In multivariate analysis, BCVA was significantly associated with the systemic parameters of lower age (P<0.001, higher level of education (P<0.001, higher body stature (P<0.001 and higher body mass index (P<0.001, and with the ophthalmic parameters of more hyperopic refractive error (spherical equivalent (P<0.001, shorter axial length (P<0.001, lower degree of nuclear cataract (P<0.001, and lower intraocular pressure (P = 0.006. The results suggest that in the rural population of Central India, major determinants of visual acuity were socioeconomic background, body stature and body mass index, age, refractive error, cataract and intraocular pressure.

  14. VISUAL ACUITY AND CLINICAL REFRACTION FOLLOWING IMPLANTATION OF VARIOUS MULTIFOCAL INTRAOCULAR LENSES

    Directory of Open Access Journals (Sweden)

    N. N. Temirov

    2015-01-01

    Full Text Available Aim. To analyze visual acuity, clinical refraction, and defocusing tolerance after the implantation of monofocal IOL with rotational asymmetric optic (Lentis Mplus 313 MF compared with Acrysof ReSTOR SN6AD1.Materials and methods. Phacoemulsification was performed in a total of 194 patients (288 eyes, i.e., 144 patients (188 eyes with cataract and 50 patients (100 eyes with presbyopia and high ametropia. The patients were divided into two groups. Study group included 132 patients (194 eyes implanted with Lentis Mplus while control group included 62 patients (94 eyes implanted with Acrysof ReSTOR. Uncorrected distance (5 m, intermediate (50‑70 cm, and near (20‑40 cm visual acuity under photopic (85 cd/m2 and mesopic (8 cd/m2 conditions were measured, objective and subjective refractometry were performed, and defocusing tolerance was evaluated.Results. Postoperatively, uncorrected distance and near visual acuity was high while intermediate visual acuity was moderately low. Lentis Mplus patients had better near and intermediate visual acuity under mesopic conditions as compared with Acrysof ReSTOR patients. Emmetropia (target refraction was achieved in 90.2% of study group patients and in 87.2% of control group patients. In patients implanted with Lentis Mplus, refraction was measured by subjective method. Optimal A-constant for Lentis Mplus and Acrysof ReSTOR was 118.0 and 118.6, respectively. Under defocusing, Lentis Mplus patients had better visual acuity than Acrysof ReSTOR patients. This indirectly confirms better intermediate vision.Conclusions. Lentis Mplus provides better vision at various distances that does not almost depend on light levels and induces minimal dysphotopsia. 

  15. Relationship between photoreceptor outer segment length and visual acuity in diabetic macular edema.

    Science.gov (United States)

    Forooghian, Farzin; Stetson, Paul F; Meyer, Scott A; Chew, Emily Y; Wong, Wai T; Cukras, Catherine; Meyerle, Catherine B; Ferris, Frederick L

    2010-01-01

    The purpose of this study was to quantify photoreceptor outer segment (PROS) length in 27 consecutive patients (30 eyes) with diabetic macular edema using spectral domain optical coherence tomography and to describe the correlation between PROS length and visual acuity. Three spectral domain-optical coherence tomography scans were performed on all eyes during each session using Cirrus HD-OCT. A prototype algorithm was developed for quantitative assessment of PROS length. Retinal thicknesses and PROS lengths were calculated for 3 parameters: macular grid (6 x 6 mm), central subfield (1 mm), and center foveal point (0.33 mm). Intrasession repeatability was assessed using coefficient of variation and intraclass correlation coefficient. The association between retinal thickness and PROS length with visual acuity was assessed using linear regression and Pearson correlation analyses. The main outcome measures include intrasession repeatability of macular parameters and correlation of these parameters with visual acuity. Mean retinal thickness and PROS length were 298 mum to 381 microm and 30 microm to 32 mum, respectively, for macular parameters assessed in this study. Coefficient of variation values were 0.75% to 4.13% for retinal thickness and 1.97% to 14.01% for PROS length. Intraclass correlation coefficient values were 0.96 to 0.99 and 0.73 to 0.98 for retinal thickness and PROS length, respectively. Slopes from linear regression analyses assessing the association of retinal thickness and visual acuity were not significantly different from 0 (P > 0.20), whereas the slopes of PROS length and visual acuity were significantly different from 0 (P < 0.0005). Correlation coefficients for macular thickness and visual acuity ranged from 0.13 to 0.22, whereas coefficients for PROS length and visual acuity ranged from -0.61 to -0.81. Photoreceptor outer segment length can be quantitatively assessed using Cirrus HD-OCT. Although the intrasession repeatability of PROS

  16. Presenting visual acuities in a new eye centre in Port Harcourt: initial ...

    African Journals Online (AJOL)

    Background: Visual acuity is a fundamental of an eye examination. It establishes in a quantitative way how well an eye can see. Apart from being a starting point in dealing with an eye, it is also a prognostic reference point and a medico-legal tool. Very few studies directly related to visual acuities are available as many ...

  17. Impact of Near Work Activity on Visual Acuity among Junior High School Students

    Directory of Open Access Journals (Sweden)

    Raisha Pratiwi Indrawati

    2016-03-01

    Full Text Available Background: Uncorrected refractive error is experienced by at least 45 million productive-aged adults (aged 16–45 years old and 13 million children (aged 5–15 years old, and being the main cause of visual impairment in children worldwide and third cause of blindness in any age in Indonesia. Near work activity is estimated as one of environmental risk factor causing this refractive error, leading into decreased visual acuity. This study was conducted to analyse the impact of near work activity on visual acuity among junior high school students in Jatinangor Methods: This study was conducted in junior high school in Jatinangor, using cross sectional method. Total of 147 subjects were screened for visual impairment using Rapid Assessment of Avoidable Blindness (RAAB tumbling E chart and assesed for near work activity using questionnaire-guided interview method after informed consent had been obtained. Data were analysed using unpaired-T test and Mann-Whitney test. Results: Total diopter hours of near work activity among the group with visual acuity ≥6/18 and group with visual acuity <6/18 showed no significant difference (p=0.329, with latter group had less time-spent in near work activity. Similarly, each activity such as reading, watching TV, and using computer also showed no significant difference , except for playing games where the group with better visual acuity had shown significantly longer time spent than another group (p=0.018. Conclusions: Near work activity does not have impact on visual acuity among junior high school students, except for playing games

  18. Vernier But Not Grating Acuity Contributes to an Early Stage of Visual Word Processing.

    Science.gov (United States)

    Tan, Yufei; Tong, Xiuhong; Chen, Wei; Weng, Xuchu; He, Sheng; Zhao, Jing

    2018-03-28

    The process of reading words depends heavily on efficient visual skills, including analyzing and decomposing basic visual features. Surprisingly, previous reading-related studies have almost exclusively focused on gross aspects of visual skills, while only very few have investigated the role of finer skills. The present study filled this gap and examined the relations of two finer visual skills measured by grating acuity (the ability to resolve periodic luminance variations across space) and Vernier acuity (the ability to detect/discriminate relative locations of features) to Chinese character-processing as measured by character form-matching and lexical decision tasks in skilled adult readers. The results showed that Vernier acuity was significantly correlated with performance in character form-matching but not visual symbol form-matching, while no correlation was found between grating acuity and character processing. Interestingly, we found no correlation of the two visual skills with lexical decision performance. These findings provide for the first time empirical evidence that the finer visual skills, particularly as reflected in Vernier acuity, may directly contribute to an early stage of hierarchical word processing.

  19. White-matter microstructure and hearing acuity in older adults: a population-based cross-sectional DTI study.

    Science.gov (United States)

    Rigters, Stephanie C; Cremers, Lotte G M; Ikram, M Arfan; van der Schroeff, Marc P; de Groot, Marius; Roshchupkin, Gennady V; Niessen, Wiro J N; Baatenburg de Jong, Robert J; Goedegebure, André; Vernooij, Meike W

    2018-01-01

    To study the relation between the microstructure of white matter in the brain and hearing function in older adults we carried out a population-based, cross-sectional study. In 2562 participants of the Rotterdam Study, we conducted diffusion tensor imaging to determine the microstructure of the white-matter tracts. We performed pure-tone audiogram and digit-in-noise tests to quantify hearing acuity. Poorer white-matter microstructure, especially in the association tracts, was related to poorer hearing acuity. After differentiating the separate white-matter tracts in the left and right hemisphere, poorer white-matter microstructure in the right superior longitudinal fasciculus and the right uncinate fasciculus remained significantly associated with worse hearing. These associations did not significantly differ between middle-aged (51-69 years old) and older (70-100 years old) participants. Progressing age was thus not found to be an effect modifier. In a voxel-based analysis no voxels in the white matter were significantly associated with hearing impairment. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. An assessment of the iPad as a testing platform for distance visual acuity in adults

    Science.gov (United States)

    Black, J M; Jacobs, R J; Phillips, G; Chen, L; Tan, E; Tran, A; Thompson, B

    2013-01-01

    Objectives Visual acuity is a common measurement in general practice, and the advent of new technology such as tablet computers offers a change in the way in which these tests are delivered. The aim of this study was to assess whether measurements of distance visual acuity using LogMAR letter charts displayed on an iPad tablet computer were in agreement with standard clinical tests of visual acuity in adults with normal vision. Design Blinded, diagnostic test study. Setting Single centre (University) in Auckland, New Zealand. Participants University staff and students (n=85). Participants were required to have visual acuity better than 6/60 and wear habitual refractive correction during testing. Participants were excluded if there was any history of ocular pathology. Primary and secondary outcome measures Visual acuity measured under a number of conditions. Results The iPad tablet with its glossy screen was highly susceptible to glare resulting in acuity measurements that were significantly poorer (approximately 2 LogMAR lines) than those made using an ETDRS chart and a standard computerised testing system (n=56). However, fitting the iPad with an antiglare screen and positioning the device away from sources creating reflected (veiling) glare resulted in acuity measurements that were equivalent those made using gold standard charts (n=29). Conclusions Tablet computers are an attractive option for visual acuity measurement due to portability, the ability to randomise letters, automated scoring of acuity and the ability to select from a range of charts. However, these devices are only suitable for use in situations where sources of glare can be eliminated. PMID:23794568

  1. Managing the impact of growing low-acuity demand on ambulance services

    OpenAIRE

    KATHRYN JEAN EASTWOOD

    2018-01-01

    Increasing demand for emergency ambulances places a substantial burden on ambulance services. Many cases are low-acuity, having no urgent clinical need for paramedic treatment. Ambulance Victoria implemented a secondary telephone triage services to divert low-acuity cases away from emergency ambulances to more appropriate care. This research found this ‘Referral Service’ has had a substantial impact upon emergency operations, referring over 70% of the cases it managed away from emergency am...

  2. Fluctuation in visual acuity during soft toric contact lens wear.

    Science.gov (United States)

    Chamberlain, Paul; Morgan, Philip B; Moody, Kurt J; Maldonado-Codina, Carole

    2011-04-01

    To quantify changes in visual acuity (VA) with soft toric contact lenses as a result of lens movement and/or rotational instability caused by versional eye movements. A novel chart for vision assessment at near (40 cm) for soft toric contact lenses (VANT chart),consisting of a central, color-coded logMAR panel and eight peripheral letter targets set on a white background measuring 60 × 40 cm was constructed. In the developmental phase of the work, 10 subjects (20 eyes) wore 2 toric lenses in random order, and the impact of rapid and delayed eye versions in 8 directions of gaze on VANT acuity was investigated. In phase 2, 35 subjects (68 eyes) wore 4 toric lenses in random order, and a streamlined clinical protocol using the VANT chart was implemented. Standard assessments of toric lens fit and distance VA were also performed. Testing in the first phase showed no difference for change in VA for rapid vs. delayed version movements, (p = 0.17) but acuity reduction was greater for diagonal compared with horizontal/vertical versions (p = 0.06). As such, testing in phase 2 proceeded using rapid, diagonal versions only. In this second phase, there were differences for low-contrast distance VA measures between lens types (p = 0.02) and for both VANT baseline acuity (p = 0.03) and postversion acuity (p = 0.04), but no differences were found between lenses for magnitude of vision loss (p = 0.91), which was about one line. No relationship was established between the magnitude of vision loss and measured rotational stability (p = 0.75). This work has demonstrated that conventional approaches to measuring VA do not fully replicate the "real world" experience of soft toric lens wearers. The VANT chart has shown that VA is reduced immediately after versional eye movements and suggests that more dynamic methods of assessing visual performance should be considered for soft toric contact lens wearers, especially given the apparent inability of lens stability measurements to predict

  3. The flex track: flexible partitioning between low- and high-acuity areas of an emergency department.

    Science.gov (United States)

    Laker, Lauren F; Froehle, Craig M; Lindsell, Christopher J; Ward, Michael J

    2014-12-01

    Emergency departments (EDs) with both low- and high-acuity treatment areas often have fixed allocation of resources, regardless of demand. We demonstrate the utility of discrete-event simulation to evaluate flexible partitioning between low- and high-acuity ED areas to identify the best operational strategy for subsequent implementation. A discrete-event simulation was used to model patient flow through a 50-bed, urban, teaching ED that handles 85,000 patient visits annually. The ED has historically allocated 10 beds to a fast track for low-acuity patients. We estimated the effect of a flex track policy, which involved switching up to 5 of these fast track beds to serving both low- and high-acuity patients, on patient waiting times. When the high-acuity beds were not at capacity, low-acuity patients were given priority access to flexible beds. Otherwise, high-acuity patients were given priority access to flexible beds. Wait times were estimated for patients by disposition and Emergency Severity Index score. A flex track policy using 3 flexible beds produced the lowest mean patient waiting time of 30.9 minutes (95% confidence interval [CI] 30.6 to 31.2 minutes). The typical fast track approach of rigidly separating high- and low-acuity beds produced a mean patient wait time of 40.6 minutes (95% CI 40.2 to 50.0 minutes), 31% higher than that of the 3-bed flex track. A completely flexible ED, in which all beds can accommodate any patient, produced mean wait times of 35.1 minutes (95% CI 34.8 to 35.4 minutes). The results from the 3-bed flex track scenario were robust, performing well across a range of scenarios involving higher and lower patient volumes and care durations. Using discrete-event simulation, we have shown that adding some flexibility into bed allocation between low and high acuity can provide substantial reductions in overall patient waiting and a more efficient ED. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc

  4. [Measuring contrast sensitivity using visual acuity tests in retinal and optic nerve diseases].

    Science.gov (United States)

    Sommer, E; Marré, E; Mierdel, P

    1990-01-01

    The luminance contrast needed to discern various test types was measured with monochromatic and achromatic light to detect discrete functional deficiencies of the retina and optic nerve in cases of normal visual acuity. Landolt rings corresponding to visual acuity levels from 0.04 to 1.0 were used as test types. A significant increase in the necessary minimum contrast was detectable with blue test light on large Landolt rings in patients with diabetic retinopathy, ocular hypertension and glaucoma and with green or yellow test light on medium-sized and small Landolt rings in patients with central serous chorioidopathy and optic atrophy. The additional contrast needed to reach the maximum visual acuity amounts to 14-100% compared with normal visual acuity, depending on the color of the test light and the diagnosis. The amount of contrast needed is greatest in retinal diseases, and it is therefore possible to a certain extent to distinguish these from diseases of the optic nerve.

  5. The Prevalence of Visual Acuity Impairment among School Children at Arada Subcity Primary Schools in Addis Ababa, Ethiopia

    Directory of Open Access Journals (Sweden)

    Haile Fentahun Darge

    2017-01-01

    Full Text Available Background. Visual impairment and blindness are major public health problems in developing countries where there is no enough health-care service. Objective. To determine the prevalence of visual impairment among school children. Materials and Methods. A school-based cross-sectional study was conducted between 15 June 2015 and 30 November 2015 at Arada subcity primary schools, Addis Ababa, Ethiopia. Two schools were selected randomly, and 378 students were screened from grades 1 to 8 using systematic random sampling method. Snellen chart was used for visual acuity test. Students who had visual acuity of ≤6/12 were further examined by an ophthalmologist to diagnose the reason for low vision. Data was analyzed using SPSS version 20. Results. A total of 378 students were screened, and 192 (50.8% were females and the remaining 186 (49.2% were males. The prevalence of visual impairment (VA of ≤6/12 on either eye was 5.8%, VA < 6/18 on either eye was 1.1%, and VA < 6/18 on the better eye was 0.53%. In this study, color blindness [OR: 19.65, 95% CI (6.01–64.33] was significantly associated with visual acuity impairment. Conclusion. The prevalence of visual impairment among school children in the study area was 5.8% and school screening is recommended.

  6. Use of the Dynamic Visual Acuity Test as a screener for community-dwelling older adults who fall.

    Science.gov (United States)

    Honaker, Julie A; Shepard, Neil T

    2011-01-01

    Adequate function of the peripheral vestibular system, specifically the vestibulo-ocular reflex (VOR; a network of neural connections between the peripheral vestibular system and the extraocular muscles) is essential for maintaining stable vision during head movements. Decreased visual acuity resulting from an impaired peripheral vestibular system may impede balance and postural control and place an individual at risk of falling. Therefore, sensitive measures of the vestibular system are warranted to screen for the tendency to fall, alerting clinicians to recommend further risk of falling assessment and referral to a falling risk reduction program. Dynamic Visual Acuity (DVA) testing is a computerized VOR assessment method to evaluate the peripheral vestibular system during head movements; reduced visual acuity as documented with DVA testing may be sensitive to screen for falling risk. This study examined the sensitivity and specificity of the computerized DVA test with yaw plane head movements for identifying community-dwelling adults (58-78 years) who are prone to falling. A total of 16 older adults with a history of two or more unexplained falls in the previous twelve months and 16 age and gender matched controls without a history of falls in the previous twelve months participated. Computerized DVA with horizontal head movements at a fixed velocity of 120 deg/sec was measured and compared with the Dynamic Gait Index (DGI) a gold standard gait assessment measurement for identifying falling risk. Receiver operating characteristics (ROC) curve analysis and area under the ROC curve (AUC) were used to assess the sensitivity and specificity of the computerized DVA as a screening measure for falling risk as determined by the DGI. Results suggested a link between computerized DVA and the propensity to fall; DVA in the yaw plane was found to be a sensitive (92%) and accurate screening measure when using a cutoff logMAR value of >0.25.

  7. Impact of Target Distance, Target Size, and Visual Acuity on the Video Head Impulse Test.

    Science.gov (United States)

    Judge, Paul D; Rodriguez, Amanda I; Barin, Kamran; Janky, Kristen L

    2018-05-01

    The video head impulse test (vHIT) assesses the vestibulo-ocular reflex. Few have evaluated whether environmental factors or visual acuity influence the vHIT. The purpose of this study was to evaluate the influence of target distance, target size, and visual acuity on vHIT outcomes. Thirty-eight normal controls and 8 subjects with vestibular loss (VL) participated. vHIT was completed at 3 distances and with 3 target sizes. Normal controls were subdivided on the basis of visual acuity. Corrective saccade frequency, corrective saccade amplitude, and gain were tabulated. In the normal control group, there were no significant effects of target size or visual acuity for any vHIT outcome parameters; however, gain increased as target distance decreased. The VL group demonstrated higher corrective saccade frequency and amplitude and lower gain as compared with controls. In conclusion, decreasing target distance increases gain for normal controls but not subjects with VL. Preliminarily, visual acuity does not affect vHIT outcomes.

  8. Crowded letter and crowded picture logMAR acuity in children with amblyopia: a quantitative comparison.

    Science.gov (United States)

    O'Boyle, Cathy; Chen, Sean I; Little, Julie-Anne

    2017-04-01

    Clinically, picture acuity tests are thought to overestimate visual acuity (VA) compared with letter tests, but this has not been systematically investigated in children with amblyopia. This study compared VA measurements with the LogMAR Crowded Kay Picture test to the LogMAR Crowded Keeler Letter acuity test in a group of young children with amblyopia. 58 children (34 male) with amblyopia (22 anisometropic, 18 strabismic and 18 with both strabismic/anisometropic amblyopia) aged 4-6 years (mean=68.7, range=48-83 months) underwent VA measurements. VA chart testing order was randomised, but the amblyopic eye was tested before the fellow eye. All participants wore up-to-date refractive correction. The Kay Picture test significantly overestimated VA by 0.098 logMAR (95% limits of agreement (LOA), 0.13) in the amblyopic eye and 0.088 logMAR (95% LOA, 0.13) in the fellow eye, respectively (pocclusion therapy, refractive correction or type of amblyopia on VA results (p>0.23). For both the amblyopic and fellow eyes, Bland-Altman plots demonstrated a systematic and predictable difference between Kay Picture and Keeler Letter charts across the range of acuities tested (Keeler acuity: amblyopic eye 0.75 to -0.05 logMAR; fellow eye 0.45 to -0.15 logMAR). Linear regression analysis (pamblyopia. Due to the predictable difference found between both crowded logMAR acuity tests, it is reasonable to adjust Kay Picture acuity thresholds by +0.10 logMAR to compute expected Keeler Letter acuity scores. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Factors accounting for the 4-year change in acuity in patients between 50 and 80 years.

    Science.gov (United States)

    Koenig, Darren E; Nguyen, Lan Chi; Parker, Katrina E; Applegate, Raymond A

    2013-07-01

    It is well known that acuity slowly decreases in the later decades of life. We wish to determine the extent by which 4-year longitudinal acuity changes can be accounted for by changes in optical quality, or combination of optical quality metrics and of age between 50 and 80 years. High-contrast logMAR acuity, 35 image quality metrics, 4 intraocular scatter metrics, and 4 Lens Opacification Classification System III metrics and entry age were measured on one eye of each of the 148 subjects. Acuity change between baseline and the last visit was regressed against change in each metric for all eyes and a faster changing subset of 50 eyes with a gain or loss of four or more letters. Average change across 148 subjects was a 1.6 ± 4 letter loss (t148 = 4.31, p model for faster changing eyes included change in point spread function entropy, posterior subcapsular cataract, and trefoil and baseline age (sequential r adjusted values of 0.19, 0.27, 0.32, and 0.34, respectively; p = 1.48 × 10 for the full four-factor model). The same variables entered the multiple-regression model for the full 148 data set where most of the acuity measurements were within test-retest error and accounted for less of the variance (r adjusted = 0.15, p = 2.37 × 10). Despite being near noise levels for the measurement of acuity, change in optical quality metrics was the most important factor in eyes that lost or gained four or more letters of acuity. These findings should be generalizable given that our 4-year acuity change is essentially identical to other studies and indicate that these optical quality markers can be used to help identify those on a faster track to an acuity change.

  10. Simulating Visibility Under Reduced Acuity and Contrast Sensitivity

    Science.gov (United States)

    Thompson, William B.; Legge, Gordon E.; Kersten, Daniel J.; Shakespeare, Robert A.; Lei, Quan

    2017-01-01

    Architects and lighting designers have difficulty designing spaces that are accessible to those with low vision, since the complex nature of most architectural spaces requires a site-specific analysis of the visibility of mobility hazards and key landmarks needed for navigation. We describe a method that can be utilized in the architectural design process for simulating the effects of reduced acuity and contrast on visibility. The key contribution is the development of a way to parameterize the simulation using standard clinical measures of acuity and contrast sensitivity. While these measures are known to be imperfect predictors of visual function, they provide a way of characterizing general levels of visual performance that is familiar to both those working in low vision and our target end-users in the architectural and lighting design communities. We validate the simulation using a letter recognition task. PMID:28375328

  11. The validity of visual acuity assessment using mobile technology devices in the primary care setting.

    Science.gov (United States)

    O'Neill, Samuel; McAndrew, Darryl J

    2016-04-01

    The assessment of visual acuity is indicated in a number of clinical circumstances. It is commonly conducted through the use of a Snellen wall chart. Mobile technology developments and adoption rates by clinicians may potentially provide more convenient methods of assessing visual acuity. Limited data exist on the validity of these devices and applications. The objective of this study was to evaluate the assessment of distance visual acuity using mobile technology devices against the commonly used 3-metre Snellen chart in a primary care setting. A prospective quantitative comparative study was conducted at a regional medical practice. The visual acuity of 60 participants was assessed on a Snellen wall chart and two mobile technology devices (iPhone, iPad). Visual acuity intervals were converted to logarithm of minimum angle of resolution (logMAR) scores and subjected to intraclass correlation coefficient (ICC) assessment. The results show a high level of general agreement between testing modality (ICC 0.917 with a 95% confidence interval of 0.887-0.940). The high level of agreement of visual acuity results between the Snellen wall chart and both mobile technology devices suggests that clinicians can use this technology with confidence in the primary care setting.

  12. Relationship between socioeconomic deprivation 
or urban/rural residence and visual acuity before cataract surgery in Northern Scotland.

    Science.gov (United States)

    Chua, Paul Y; Mustafa, Mohammed S; Scott, Neil W; Kumarasamy, Manjula; Azuara-Blanco, Augusto

    2013-01-01

    To evaluate the influence of socioeconomic factors on visual acuity before cataract surgery. 
 The medical case notes of 240 consecutive patients listed for cataract surgery from January 1, 2010, at Grampian University Hospital, Aberdeen, were reviewed retrospectively. Patients with ocular comorbidity were excluded. Demographics, postal codes, and visual acuity were recorded. Scottish Index of Multiple Deprivation was used to determine the deprivation rank. Home location was classified as urban or rural. The effect of these parameters on preoperative visual acuity was investigated using chi-square tests or Fisher exact test as appropriate. 
 A total of 184 patients (mean 75 years) were included. A total of 127 (69%) patients had visual acuity of 6/12 or better. An association was found between affluence and preoperative visual acuity of 6/12 or better (χ2trend = 4.97, p = 0.03), with a significant rising trend across quintile of deprivation. There was no evidence to suggest association between geographical region and preoperative visual acuity (p = 0.63). 
 Affluence was associated with good visual acuity (6/12 or better) before cataract surgery. There was no difference in preoperative visual acuity between rural and urban populations.

  13. Visual acuity and quality of life in dry eye disease: Proceedings of the OCEAN group meeting.

    Science.gov (United States)

    Benítez-Del-Castillo, José; Labetoulle, Marc; Baudouin, Christophe; Rolando, Maurizio; Akova, Yonca A; Aragona, Pasquale; Geerling, Gerd; Merayo-Lloves, Jesús; Messmer, Elisabeth M; Boboridis, Kostas

    2017-04-01

    Dry eye disease (DED) results in tear film instability and hyperosmolarity, inflammation of the ocular surface and, ultimately, visual disturbance that can significantly impact a patient's quality of life. The effects on visual acuity result in difficulties with driving, reading and computer use and negatively impact psychological health. These effects also extend to the workplace, with a loss of productivity and quality of work causing substantial economic losses. The effects of DED and the impact on vision experienced by patients may not be given sufficient importance by ophthalmologists. Functional visual acuity (FVA) is a measure of visual acuity after sustained eye opening without blinking for at least 10 s and mimics the sustained visual acuity of daily life. Measuring dynamic FVA allows the detection of impaired visual function in patients with DED who may display normal conventional visual acuity. There are currently several tests and methods that can be used to measure dynamic visual function: the SSC-350 FVA measurement system, assessment of best-corrected visual acuity decay using the interblink visual acuity decay test, serial measurements of ocular and corneal higher order aberrations, and measurement of dynamic vision quality using the Optical Quality Analysis System. Although the equipment for these methods may be too large or unaffordable for use in clinical practice, FVA testing is an important assessment for DED. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Femtosecond laser-assisted LASIK versus PRK for high myopia: comparison of 18-month visual acuity and quality.

    Science.gov (United States)

    Hashemi, Hassan; Ghaffari, Reza; Miraftab, Mohammad; Asgari, Soheila

    2017-08-01

    To compare 18-month outcomes between femtosecond laser-assisted LASIK (femto-LASIK) and photorefractive keratectomy with mitomycin-C (PRK-MMC) for myopia of more than 7.0 D in terms of visual acuity and quality. In this comparative nonrandomized clinical trial, 60 eyes from 30 patients (30 eyes in each group) were enrolled. The two procedures were compared in terms of 18-month changes in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, ocular and corneal higher order aberrations (HOAs), and contrast sensitivity (CS). Mean myopia was -8.65 ± 1.51 and -8.04 ± 1.70 D (P = 0.149) and mean ablation depth was 109.37 ± 9.07 and 105.09 ± 12.59 µm (P = 0.138), in the femto-LASIK and PRK-MMC groups, respectively. Baseline parameters were not significantly different between the two groups (all P > 0.05). At 18 months postoperatively, 75 % in the femto-LASIK, versus 57.1 % in the PRK-MMC group, had 20/20 UDVA (P = 0.017). CDVA remained similarly unchanged in both groups (P = 0.616). No case had residual refractive error more than 1.0 D in the femto-LASIK group, while 33.5 % in the other group had more than 1.0 D residual error (P = 0.390). Changes in corneal HOA were not significantly different between the two groups (P = 0.260). Cases in the femto-LASIK group showed more increase in ocular HOA (P = 0.032) and coma (P = 0.083, power = 72 %). CS remained similarly unchanged in all spatial frequencies in both groups (all P > 0.05). Although femto-LASIK induces more HOA compared to PRK-MMC, considering outcomes in terms of 20/20 UDVA, residual refractive error, and CS stability, femto-LASIK provides more favorable results than PRK-MMC in high myopia.

  15. The use of acuity and frailty measures for district nursing workforce plans.

    Science.gov (United States)

    David, Ami; Saunders, Mary

    2018-02-02

    This article discusses the use of Quest acuity and frailty measures for community nursing interventions to quantify and qualify the contributions of district nursing teams. It describes the use of a suite of acuity and frailty tools tested in 8 UK community service trusts over the past 5years. In addition, a competency assessment tool was used to gauge both capacity and capability of individual nurses. The consistency of the results obtained from the Quest audits offer significant evidence and potential for realigning community nursing services to offer improvements in efficiency and cost-effectiveness. The National Quality Board (NQB) improvement resource for the district nursing services ( NQB, 2017 ) recommends a robust method for classifying patient acuity/frailty/dependency. It is contended the Quest tools and their usage articulated here offer a suitable methodology.

  16. High visual acuity revealed in dogs.

    Science.gov (United States)

    Lind, Olle; Milton, Ida; Andersson, Elin; Jensen, Per; Roth, Lina S V

    2017-01-01

    Humans have selectively bred and used dogs over a period of thousands of years, and more recently the dog has become an important model animal for studies in ethology, cognition and genetics. These broad interests warrant careful descriptions of the senses of dogs. Still there is little known about dog vision, especially what dogs can discriminate in different light conditions. We trained and tested whippets, pugs, and a Shetland sheepdog in a two-choice discrimination set-up and show that dogs can discriminate patterns with spatial frequencies between 5.5 and 19.5 cycle per degree (cpd) in the bright light condition (43 cd m-2). This is a higher spatial resolution than has been previously reported although the individual variation in our tests was large. Humans tested in the same set-up reached acuities corresponding to earlier studies, ranging between 32.1 and 44.2 cpd. In the dim light condition (0.0087 cd m-2) the acuity of dogs ranged between 1.8 and 3.5 cpd while in humans, between 5.9 and 9.9 cpd. Thus, humans make visual discrimination of objects from roughly a threefold distance compared to dogs in both bright and dim light.

  17. High visual acuity revealed in dogs.

    Directory of Open Access Journals (Sweden)

    Olle Lind

    Full Text Available Humans have selectively bred and used dogs over a period of thousands of years, and more recently the dog has become an important model animal for studies in ethology, cognition and genetics. These broad interests warrant careful descriptions of the senses of dogs. Still there is little known about dog vision, especially what dogs can discriminate in different light conditions. We trained and tested whippets, pugs, and a Shetland sheepdog in a two-choice discrimination set-up and show that dogs can discriminate patterns with spatial frequencies between 5.5 and 19.5 cycle per degree (cpd in the bright light condition (43 cd m-2. This is a higher spatial resolution than has been previously reported although the individual variation in our tests was large. Humans tested in the same set-up reached acuities corresponding to earlier studies, ranging between 32.1 and 44.2 cpd. In the dim light condition (0.0087 cd m-2 the acuity of dogs ranged between 1.8 and 3.5 cpd while in humans, between 5.9 and 9.9 cpd. Thus, humans make visual discrimination of objects from roughly a threefold distance compared to dogs in both bright and dim light.

  18. Relationship between Outer Retinal Layers Thickness and Visual Acuity in Diabetic Macular Edema

    Directory of Open Access Journals (Sweden)

    Raymond L. M. Wong

    2015-01-01

    Full Text Available Purpose. To investigate the correlation of outer retinal layers (ORL thickness and visual acuity (VA in patients with diabetic macular edema (DME. Methods. Consecutive DME patients seen at the Retina Clinic of The University of Hong Kong were recruited for OCT assessment. The ORL thickness was defined as the distance between external limiting membrane (ELM and retinal pigment epithelium (RPE at the foveal center. The correlation between total retinal thickness, ORL thickness, and vision was calculated. Results. 78 patients with DME were recruited. The mean age was 58.1 years (±11.5 years and their mean visual acuity measured with Snellen chart was 0.51 (±0.18. The correlation coefficient between total retinal thickness and visual acuity was 0.34 (P < 0.001 whereas the correlation coefficient was 0.65 between ORL thickness and visual acuity (P < 0.001. Conclusion. ORL thickness correlates better with vision than the total retinal thickness. It is a novel OCT parameter in the assessment of DME. Moreover, it could be a potential long term visual prognostic factor for patients with DME.

  19. Proprioceptive acuity into knee hypermobile range in children with Joint Hypermobility Syndrome

    OpenAIRE

    Pacey, Verity; Adams, Roger D; Tofts, Louise; Munns, Craig F; Nicholson, Leslie L

    2014-01-01

    Background Children with Joint Hypermobility Syndrome (JHS) have reduced knee joint proprioceptive acuity compared to peers. Altered proprioception at end of range in individuals with JHS is hypothesised to contribute to recurrent joint injuries and instability. This study aims to provide the first objective comparison of functional knee joint proprioceptive acuity in hyperextension range compared to early flexion range in children with JHS. Methods Active, weight-bearing knee joint proprioce...

  20. Bevacizumab Injection in Patients with Age-Related Macular Degeneration Associated with Poor Initial Visual Acuity

    Directory of Open Access Journals (Sweden)

    Leila El Matri

    2012-01-01

    Full Text Available Purpose. To evaluate functional and anatomic effects of intravitreal bevacizumab in patients with neovascular AMD and initial low visual acuity. Methods. Retrospective case series of 38 eyes with neovascular AMD and initial visual acuity of 20/200 or less, treated with intravitreal bevacizumab injection. Results. Mean followup was 14.1 months ±7.1 (range: 5 to 24 months. Mean logMAR vision at baseline was 1.38 logMAR ±0.33, at 6 months was 1.14 logMAR ±0.37 (=0.001 and at 12 months was 1.22 logMar ±0.33 (=0.004. Mean baseline central retinal thickness was 431 μm ±159.7 at 6 months was 293.43 μm  ±122.79 (=10−4 and at 12 months was 293.1 μm  ±130 (=0.004. Visual acuity improved in both patients with or without prior PDT treatment. Conclusions. Intravitreal bevacizumab injection may increase the chance of visual acuity gain in neovascular AMD even in cases with initial low visual acuity.

  1. Eye size and visual acuity influence vestibular anatomy in mammals.

    Science.gov (United States)

    Kemp, Addison D; Christopher Kirk, E

    2014-04-01

    The semicircular canals of the inner ear detect head rotations and trigger compensatory movements that stabilize gaze and help maintain visual fixation. Mammals with large eyes and high visual acuity require precise gaze stabilization mechanisms because they experience diminished visual functionality at low thresholds of uncompensated motion. Because semicircular canal radius of curvature is a primary determinant of canal sensitivity, species with large canal radii are expected to be capable of more precise gaze stabilization than species with small canal radii. Here, we examine the relationship between mean semicircular canal radius of curvature, eye size, and visual acuity in a large sample of mammals. Our results demonstrate that eye size and visual acuity both explain a significant proportion of the variance in mean canal radius of curvature after statistically controlling for the effects of body mass and phylogeny. These findings suggest that variation in mean semicircular canal radius of curvature among mammals is partly the result of selection for improved gaze stabilization in species with large eyes and acute vision. Our results also provide a possible functional explanation for the small semicircular canal radii of fossorial mammals and plesiadapiforms. Copyright © 2014 Wiley Periodicals, Inc.

  2. Recognition versus Resolution: a Comparison of Visual Acuity Results Using Two Alternative Test Chart Optotype

    OpenAIRE

    Jonathan S. Pointer

    2008-01-01

    Purpose: To quantify the difference between recognition (letter) and resolution (Landolt) visual acuity (VA) in a group of normally sighted subjects. Is it reasonable to assume that the two acuity measures are clinically equivalent? Methods: A pair of 6 m acuity test charts was produced: one comprised letters and the other Landolt broken rings. Construction of both charts conformed to the logMAR design format. Monocular VA was determined for the dominant eye of 300 screened and normally si...

  3. The Incidence of Postconcussion Syndrome Remains Stable Following Mild Traumatic Brain Injury in Children.

    Science.gov (United States)

    Barlow, Karen M; Crawford, Susan; Brooks, Brian L; Turley, Brenda; Mikrogianakis, Angelo

    2015-12-01

    Improving our knowledge about the natural history and persistence of symptoms following mild traumatic brain injury is a vital step in improving the provision of health care to children with postconcussion syndrome. The purposes of this study were to (1) determine the incidence and persistence of symptoms after mild traumatic brain injury and (2) ascertain whether Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), symptom criteria for postconcussion syndrome in adults are appropriate for use in children. A tertiary care pediatric emergency department was the setting for this study. This was a prospective observational follow-up cohort study of children (ages 2 to 18 years) with mild traumatic brain injury. Data were collected in person during the acute presentation, and subsequent follow-up was performed by telephone at 7-10 days and 1, 2, and 3 months postinjury. Postconcussion Symptom Inventory for parents and children was used. The DSM-IV diagnostic criteria for postconcussion syndrome were explored using receiver operating characteristic curve analysis. A total of 467 children (62.5% boys, median age 12.04, range 2.34-18.0) with mild traumatic brain injury participated. The median time until symptom resolution was 29.0 days (95% confidence intervals: 26.09-31.91). Three months after injury, 11.8% of children with mild traumatic brain injury remained symptomatic. Receiver operating curve characteristic analysis of the postconcussion syndrome criteria successfully classified symptomatic participants at three months postinjury; the adolescent receiver operating characteristic curve was excellent with the area under the curve being 0.928 (P children presenting to the emergency room with a mild traumatic brain injury remain symptomatic at 3 months postinjury. This is the first study to demonstrate stable incidence rates of postconcussion syndrome in children and that modified DSM-IV criteria can be used to successfully classify

  4. Visual Temporal Acuity Is Related to Auditory Speech Perception Abilities in Cochlear Implant Users.

    Science.gov (United States)

    Jahn, Kelly N; Stevenson, Ryan A; Wallace, Mark T

    Despite significant improvements in speech perception abilities following cochlear implantation, many prelingually deafened cochlear implant (CI) recipients continue to rely heavily on visual information to develop speech and language. Increased reliance on visual cues for understanding spoken language could lead to the development of unique audiovisual integration and visual-only processing abilities in these individuals. Brain imaging studies have demonstrated that good CI performers, as indexed by auditory-only speech perception abilities, have different patterns of visual cortex activation in response to visual and auditory stimuli as compared with poor CI performers. However, no studies have examined whether speech perception performance is related to any type of visual processing abilities following cochlear implantation. The purpose of the present study was to provide a preliminary examination of the relationship between clinical, auditory-only speech perception tests, and visual temporal acuity in prelingually deafened adult CI users. It was hypothesized that prelingually deafened CI users, who exhibit better (i.e., more acute) visual temporal processing abilities would demonstrate better auditory-only speech perception performance than those with poorer visual temporal acuity. Ten prelingually deafened adult CI users were recruited for this study. Participants completed a visual temporal order judgment task to quantify visual temporal acuity. To assess auditory-only speech perception abilities, participants completed the consonant-nucleus-consonant word recognition test and the AzBio sentence recognition test. Results were analyzed using two-tailed partial Pearson correlations, Spearman's rho correlations, and independent samples t tests. Visual temporal acuity was significantly correlated with auditory-only word and sentence recognition abilities. In addition, proficient CI users, as assessed via auditory-only speech perception performance, demonstrated

  5. Creation of an Accurate Algorithm to Detect Snellen Best Documented Visual Acuity from Ophthalmology Electronic Health Record Notes.

    Science.gov (United States)

    Mbagwu, Michael; French, Dustin D; Gill, Manjot; Mitchell, Christopher; Jackson, Kathryn; Kho, Abel; Bryar, Paul J

    2016-05-04

    Visual acuity is the primary measure used in ophthalmology to determine how well a patient can see. Visual acuity for a single eye may be recorded in multiple ways for a single patient visit (eg, Snellen vs. Jäger units vs. font print size), and be recorded for either distance or near vision. Capturing the best documented visual acuity (BDVA) of each eye in an individual patient visit is an important step for making electronic ophthalmology clinical notes useful in research. Currently, there is limited methodology for capturing BDVA in an efficient and accurate manner from electronic health record (EHR) notes. We developed an algorithm to detect BDVA for right and left eyes from defined fields within electronic ophthalmology clinical notes. We designed an algorithm to detect the BDVA from defined fields within 295,218 ophthalmology clinical notes with visual acuity data present. About 5668 unique responses were identified and an algorithm was developed to map all of the unique responses to a structured list of Snellen visual acuities. Visual acuity was captured from a total of 295,218 ophthalmology clinical notes during the study dates. The algorithm identified all visual acuities in the defined visual acuity section for each eye and returned a single BDVA for each eye. A clinician chart review of 100 random patient notes showed a 99% accuracy detecting BDVA from these records and 1% observed error. Our algorithm successfully captures best documented Snellen distance visual acuity from ophthalmology clinical notes and transforms a variety of inputs into a structured Snellen equivalent list. Our work, to the best of our knowledge, represents the first attempt at capturing visual acuity accurately from large numbers of electronic ophthalmology notes. Use of this algorithm can benefit research groups interested in assessing visual acuity for patient centered outcome. All codes used for this study are currently available, and will be made available online at https://phekb.org.

  6. Stimulus-dependent effects on tactile spatial acuity

    Directory of Open Access Journals (Sweden)

    Tommerdahl M

    2005-10-01

    Full Text Available Abstract Background Previous studies have shown that spatio-tactile acuity is influenced by the clarity of the cortical response in primary somatosensory cortex (SI. Stimulus characteristics such as frequency, amplitude, and location of tactile stimuli presented to the skin have been shown to have a significant effect on the response in SI. The present study observes the effect of changing stimulus parameters of 25 Hz sinusoidal vertical skin displacement stimulation ("flutter" on a human subject's ability to discriminate between two adjacent or near-adjacent skin sites. Based on results obtained from recent neurophysiological studies of the SI response to different conditions of vibrotactile stimulation, we predicted that the addition of 200 Hz vibration to the same site that a two-point flutter stimulus was delivered on the skin would improve a subject's spatio-tactile acuity over that measured with flutter alone. Additionally, similar neurophysiological studies predict that the presence of either a 25 Hz flutter or 200 Hz vibration stimulus on the unattended hand (on the opposite side of the body from the site of two-point limen testing – the condition of bilateral stimulation – which has been shown to evoke less SI cortical activity than the contralateral-only stimulus condition would decrease a subject's ability to discriminate between two points on the skin. Results A Bekesy tracking method was employed to track a subject's ability to discriminate between two-point stimuli delivered to the skin. The distance between the two points of stimulation was varied on a trial-by-trial basis, and several different stimulus conditions were examined: (1 The "control" condition, in which 25 Hz flutter stimuli were delivered simultaneously to the two points on the skin of the attended hand, (2 the "complex" condition, in which a combination of 25 Hz flutter and 200 Hz vibration stimuli were delivered to the two points on the attended hand, and (3 a

  7. Lawn mower injuries as a cause of serious visual acuity impairment - Case reports.

    Science.gov (United States)

    Jasielska, Monika; Winiarczyk, Mateusz; Bieliński, Paweł; Mackiewicz, Jerzy

    2017-05-11

    [b]Abstract Objective.[/b] The aim of the study is to present four cases of lawn mowers injuries as a cause of serious visual acuity impairment. [b]Materials and Method[/b]. A retrospective study of four patients admitted in 2013-2015 to the Department of Vitreoretinal Surgery in Lublin with severe open or closed globe injury, one with an intraocular foreign body (IOFB). The presence of eye protective equipment was assessed, as well as visual acuity, eye tissue condition before and after treatment, and applied therapy. In all cases an improvement was achieved in local conditions. The intraocular foreign body was removed, wounds sutured and damaged tissues placed in position. All eyeballs were saved. In three cases, visual acuity was improved to a usable level. Three patients underwent pars plana vitrectomy, one with IOFB removal from the vitreous cavity. [b]Conclusions[/b]. Lawn mower induced eye injuries are a significant cause of serious visual acuity impairment or blindness. The presented study shows that lawn mower eye injuries are still a therapeutic, social and economic problem, yet are very preventable with proper eye protection and patients' education. Current prevention strategies are inadequate, and therefore should be updated.

  8. Gender and environmental influences on visual acuity in Owerri ...

    African Journals Online (AJOL)

    olayemitoyin

    1Optometry Unit, Eye Clinic, Federal Medical Centre, Owerri, Imo State, 2Department of Physiology, College ... Visual acuity (V.A.) is a measure of visual function in health and disease. ..... environment especially during harmattan and dry.

  9. [Evaluation of visual acuity in a historical cohort of 137 patients treated for amblyopia by occlusion 30-35 years ago].

    Science.gov (United States)

    Simonsz-Tóth, B; Loudon, S E; van Kempen-du Saar, H; van de Graaf, E S; Groenewoud, J H; Simonsz, H J

    2007-01-01

    Opinions differ on the course of the visual acuity in the amblyopic eye after cessation of occlusion therapy. This study evaluated visual acuity in a historical cohort treated for amblyopia with occlusion therapy 30-35 years ago. Between 1968 and 1975, 1250 patients had been treated by the orthoptist in the Waterland Hospital in Purmerend, The Netherlands. Of these, 471 received occlusion treatment for amblyopia (prevalence 5.0%, after comparison with the local birth rate). We were able to contact 203 of these patients, 137 were orthoptically re-examined in 2003. We correlated the current visual acuity with the cause of amblyopia, the age at start and end of treatment, the visual acuity at start and end of treatment, fixation, binocular vision and refractive errors. Mean age at the start of treatment was 5.4 +/- 1.9 years, 7.4 +/- 1.7 years at the end and 37 +/- 2.7 years at follow-up. Current visual acuity in the amblyopic eye was correlated with a low visual acuity at the start (p occlusion therapy, an eccentric fixation (p amblyopia (p = 0.005). At the end of the treatment, patients with a strabismic amblyopia (n = 98) had a visual acuity in the amblyopic eye of 0.29 logMAR +/- 0.3, and in 2003 0.27 +/- 0.3 logMAR. In patients with an anisometropic amblyopia (> 1 D, n = 16) visual acuity had decreased from 0.17 +/- 0.23 logMAR to 0.21 logMAR +/- 0.23. In patients with both strabismic and anisometropic amblyopia (n = 23), visual acuity had decreased from 0.52 logMAR +/- 0.54 to 0.65 logMAR +/- 0.54. Overall, acuity had decreased in 54 patients (39%) after cessation of treatment. Of these, 18 patients had an acuity decrease to less than 50% of their acuity at the end of treatment. In 15 of these 18 patients anisohypermetropia had increased. A decrease in visual acuity after cessation of occlusion therapy occurred in patients with a combined cause of amblyopia or with an increase in anisohypermetropia.

  10. Visual acuity loss associated with excessive “dry macula” in exudative age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Takahashi H

    2018-02-01

    Full Text Available Hidenori Takahashi,1–3 Yuji Inoue,1,2 Xue Tan,2,3 Satoru Inoda,1 Shinichi Sakamoto,1 Yusuke Arai,1 Yasuo Yanagi,4–6 Yujiro Fujino,2,3 Hidetoshi Kawashima1 1Department of Ophthalmology, Jichi Medical University, Shimotsuke, 2Department of Ophthalmology, The University of Tokyo, Bunkyo, 3Department of Ophthalmology, Japan Community Health Care Organization Tokyo Shinjuku Medical Center, Shinjuku, Japan; 4Medical Retina, Singapore National Eye Centre, 5Medical Retina, Singapore Eye Research Institute, 6Eye-ACP, Duke NUS Medical School, National University of Singapore, Singapore Purpose: To investigate the correlation between visual acuity and central macular thickness (CMT and choroidal thickness (CCT in patients with wet age-related macular degeneration (AMD. Methods: In this retrospective analysis, 14 eyes that received >10 ranibizumab injections (based on pro re nata [PRN] regimen and maintained initial visual acuity gain were analyzed. The following 5 parameters were measured at the foveal center: CMT (distance from the inner limiting membrane [ILM] to Bruch’s membrane; central retinal thickness (CRT; distance from the ILM to the inner limit of the retinal pigment epithelium or subretinal fluid [SRF]; SRF thickness (SRFT; pigment epithelium detachment thickness (PEDT; and CCT. The correlation between the logarithm of the minimum angle of resolution (logMAR best-corrected visual acuity (BCVA and the 5 parameters was examined with generalized estimating equations. Results: CMT, CRT, and CCT were negatively correlated with logMAR BCVA (P=0.031, 0.023, and 0.036, respectively when only CMT values less than the thickness that maximized visual acuity for each eye were used for the analysis. Each 100-µm reduction in CMT, CRT, or CCT improved logMAR BCVA by -0.1, -0.08, or -0.07, respectively. SRFT and PEDT were not correlated with BCVA. The median CMT that maximized the visual acuity was 230 µm. Conclusion: Dry macula with CMT <230 µm was

  11. Tactile acuity is disrupted in osteoarthritis but is unrelated to disruptions in motor imagery performance.

    NARCIS (Netherlands)

    Stanton, T.R.; Lin, C.W.; Bray, H.; Smeets, R.J.P.; Taylor, D.; Law, R.Y.; Moseley, G.L.

    2013-01-01

    OBJECTIVE: To determine whether tactile acuity is disrupted in people with knee OA and to determine whether tactile acuity, a clinical signature of primary sensory cortex representation, is related to motor imagery performance (MIP; evaluates working body schema) and pain. METHODS: Experiment 1:

  12. A comparison of static near stereo acuity in youth baseball/softball players and non-ball players.

    Science.gov (United States)

    Boden, Lauren M; Rosengren, Kenneth J; Martin, Daniel F; Boden, Scott D

    2009-03-01

    Although many aspects of vision have been investigated in professional baseball players, few studies have been performed in developing athletes. The issue of whether youth baseball players have superior stereopsis to nonplayers has not been addressed specifically. The purpose of this study was to determine if youth baseball/softball players have better stereo acuity than non-ball players. Informed consent was obtained from 51 baseball/softball players and 52 non-ball players (ages 10 to 18 years). Subjects completed a questionnaire, and their static near stereo acuity was measured using the Randot Stereotest (Stereo Optical Company, Chicago, Illinois). Stereo acuity was measured as the seconds of arc between the last pair of images correctly distinguished by the subject. The mean stereo acuity score was 25.5 +/- 1.7 seconds of arc in the baseball/softball players and 56.2 +/- 8.4 seconds of arc in the non-ball players. This difference was statistically significant (P softball players had significantly better static stereo acuity than non-ball players, comparable to professional ball players.

  13. Impacts of global warming on phenology of spring leaf unfolding remain stable in the long run.

    Science.gov (United States)

    Wang, Huanjiong; Rutishauser, This; Tao, Zexing; Zhong, Shuying; Ge, Quansheng; Dai, Junhu

    2017-02-01

    The impact of spring temperature forcing on the timing of leaf unfolding of plants (temperature sensitivity, S T ) is one important indicator of how and to what degree plant species track climate change. Fu et al. (Nature 526:104-107, 2015) found that S T has significantly decreased from the 1980-1994 to the 1999-2013 period for seven mid-latitude tree species in Europe. However, long-term changes in S T over the past 60 years are still not clear. Here, using in situ observations of leaf unfolding for seven dominant European tree species, we analyze the temporal change in S T over decadal time scales extending the data series back to 1951. Our results demonstrate that S T shows no statistically significant change within shifting 30-year windows from 1951 to 2013 and remains stable between 1951-1980 and 1984-2013 (3.6 versus 3.7 days °C -1 ). This result suggests that the significant decrease in S T over the past 33 years could not be sustained when examining the trends of phenological responses in the long run. Therefore, we could not conclude that tree spring phenology advances will slow down in the future, and the S T changes in warming scenarios are still uncertain.

  14. Prevalence of high astigmatism, eyeglass wear, and poor visual acuity among Native American grade school children.

    Science.gov (United States)

    Harvey, Erin M; Dobson, Velma; Miller, Joseph M

    2006-04-01

    The purpose of this study was to examine the prevalence of astigmatism and poor visual acuity and rate of eyeglass wear in grade school children who are members of a Native American tribe reported to have a high prevalence of large amounts of astigmatism. Vision screening was conducted on 1,327 first through eighth grade children attending school on the Tohono O'odham Reservation. Noncycloplegic autorefraction was conducted on the right and left eye of each child using the Nikon Retinomax K+ autorefractor, and monocular recognition acuity was tested using ETDRS logarithm of the minimum angle of resolution (logMAR) letter charts. Tohono O'odham children had a high prevalence of high astigmatism (42% had > or = 1.00 D in the right or left eye) and the axis of astigmatism was uniformly with-the-rule. However, only a small percentage of children arrived at the vision screening wearing glasses, and the prevalence of poor visual acuity (20/40 or worse in either eye) was high (35%). There was a significant relation between amount of astigmatism and uncorrected visual acuity with each additional diopter of astigmatism resulting in an additional 1 logMAR line reduction in visual acuity. Uncorrected astigmatism and poor visual acuity are prevalent among Tohono O'odham children. The results highlight the importance of improving glasses-wearing compliance, determining barriers to receiving eye care, and initiating public education programs regarding the importance of early identification and correction of astigmatism in Tohono O'odham children.

  15. Correlation Between Near-Vision Acuity and the Incidence of Peritoneal Dialysis-Related Infections.

    Science.gov (United States)

    Kojima, Shigeki; Sakurada, Tsutomu; Koitabashi, Kenichiro; Kojima, Kaori; Watanabe, Shiika; Uchida, Daisuke; Kaneshiro, Nagayuki; Konno, Yusuke; Shibagaki, Yugo

    Peritoneal dialysis (PD)-related infections (PDIs) such as peritonitis, exit-site infection, and tunnel infection are serious complications affecting patients on PD. Because patients with diabetes (DM) and of older age have increased in number in Japan, the number of patients with visual impairment is estimated also to have increased. Near vision is necessary for performing proper PD daily care. However, no studies have reported whether visual impairment is likely to increase the risk of PDIs.Our study included 31 PD patients (16 men, 15 women; mean age: 61.5 ± 11.8 years; mean PD duration: 27.3 ± 20.3 months; 38.7% with DM; 54.8% wearing glasses) who performed their own PD care. At our facility and related facilities, we used a standard near-vision test chart, which classifies vision into 12 grades, from 0.1 (poor) to 1.5 (clear), to assess near-vision binocular visual acuity in those patients between March 2015 and September 2015. In addition, we retrospectively examined the medical records of the patients to determine their history of PDIs. We then evaluated the correlation between near-vision acuity and the incidence of PDIs.Mean measured near-vision acuity was 0.61 ± 0.29, and we observed no significant difference in the visual acuity of patients with and without DM (0.55 ± 0.31 vs. 0.63 ± 0.26 respectively, p = 0.477). In addition, we observed no significant difference in the incidence of PDIs between patients with and without DM (1.298 ± 1.609 per year vs. 1.164 ± 0.908 per year respectively, p = 0.804). We did not find a correlation between near-vision acuity and the incidence of PDIs (r = -0.071, p = 0.795).

  16. A new specialized visual acuity chart for amblyopic children aged 3-5 years old:development and its clinical applications

    Directory of Open Access Journals (Sweden)

    Yang-Qing Huang

    2013-12-01

    Full Text Available AIM: To introduce a new specialized visual acuity chart for amblyopic children aged 3-5 years old and its clinical applications.METHODS:The new visual acuity chart and notations were designed based on Weber-Fechner law. The optotypes were red against a white background and were specially shaped four basic geometric symbols:circle, square, triangle,and cross. A regular geometric progression of the optotype sizes and distribution was employed to arrange in 14 lines. The progression rate of the optotype size between two lines was 1.2589 and the testing distance was 3m. Visual acuity score could be recorded as logMAR notation or decimal notation. Age-stratified diagnostic criteria for amblyopia established by consensus statement on diagnosis of amblyopia (2011 among members of the Strabismus and Pediatric Ophthalmology Group, Ophthalmology Society, Chinese Medical Association (SPOGOSCMA were illustrated in the new visual acuity chart.RESULTS: When assessing visual acuity in children aged 3-5 years old, this new visual acuity chart that consists of four symmetrical shapes (triangle, square, cross, and circle overcame an inability to recognize the letters of the alphabet and difficulties in designating the direction of black abstract symbols such as the tumbling ‘E’ or Landolt ‘C’, which the subjects were prone to lose interest in. The visual acuity score may be recorded in different notations:decimal acuity and logMAR. These two notations can be easily converted each other in the new eye chart. The measurements of this new chart not only showed a significant correlation and a good consistency with the international standard logarithmic visual acuity chart (r=0.932, P<0.01, but also indicated a high test-retest reliability (89% of retest scores were within 0.1logMAR units of the initial test score.CONCLUSION: The results of this study support the validity and reliability of distance visual acuity measurements using the new eye chart in

  17. An Acuity Tool for Heart Failure Case Management: Quantifying Workload, Service Utilization, and Disease Severity.

    Science.gov (United States)

    Kilgore, Matthew D

    The cardiology service line director at a health maintenance organization (HMO) in Washington State required a valid, reliable, and practical means for measuring workloads and other productivity factors for six heart failure (HF) registered nurse case managers located across three geographical regions. The Kilgore Heart Failure Case Management (KHFCM) Acuity Tool was systematically designed, developed, and validated to measure workload as a dependent function of the number of heart failure case management (HFCM) services rendered and the duration of times spent on various care duties. Research and development occurred at various HMO-affiliated internal medicine and cardiology offices throughout Western Washington. The concepts, methods, and principles used to develop the KHFCM Acuity Tool are applicable for any type of health care professional aiming to quantify workload using a high-quality objective tool. The content matter, scaling, and language on the KHFCM Acuity Tool are specific to HFCM settings. The content matter and numeric scales for the KHFCM Acuity Tool were developed and validated using a mixed-method participant action research method applied to a group of six outpatient HF case managers and their respective caseloads. The participant action research method was selected, because the application of this method requires research participants to become directly involved in the diagnosis of research problems, the planning and execution of actions taken to address those problems, and the implementation of progressive strategies throughout the course of the study, as necessary, to produce the most credible and practical practice improvements (; ; ; ). Heart failure case managers served clients with New York Heart Association Functional Class III-IV HF (), and encounters were conducted primarily by telephone or in-office consultation. A mix of qualitative and quantitative results demonstrated a variety of quality improvement outcomes achieved by the design

  18. An Audit of Visual Acuity using a Snellen chart for Residents in a Care home, aged 65years or over

    OpenAIRE

    Ward, Hannah

    2012-01-01

    Background: Visual impairment (VI) is highly prevalent, but currently remains untreated and preventable in Britain‟s older population (Evans, Fletcher, Wormald et al. 2002). Eighty percent of all VI can be avoided or treated (WHO, 2011). People in residential or nursing homes are at a higher risk of having their eye problems overlooked (Pols, Bates, McGraw et al. 2000). Aim: To conduct an audit of visual acuity (VA), a measure of VI against a national standard, the British Geriatric Societ...

  19. Influence of Passive Joint Stiffness on Proprioceptive Acuity in Individuals With Functional Instability of the Ankle.

    Science.gov (United States)

    Marinho, Hellen Veloso Rocha; Amaral, Giovanna Mendes; de Souza Moreira, Bruno; Araújo, Vanessa Lara; Souza, Thales Rezende; Ocarino, Juliana Melo; da Fonseca, Sérgio Teixeira

    2017-12-01

    Study Design Controlled laboratory study, cross-sectional. Background Deficits in ankle proprioceptive acuity have been reported in persons with functional instability of the ankle. Passive stiffness has been proposed as a possible mechanism underlying proprioceptive acuity. Objective To compare proprioceptive acuity and passive ankle stiffness in persons with and without functional ankle instability, and to assess the influence of passive joint stiffness on proprioceptive acuity in persons with functional ankle instability. Methods A sample of 18 subjects with and 18 without complaints of functional ankle instability following lateral ankle sprain participated. An isokinetic dynamometer was used to compare motion perception threshold, passive position sense, and passive ankle stiffness between groups. To evaluate the influence of passive stiffness on proprioceptive acuity, individuals in the lateral functional ankle instability group were divided into 2 subgroups: "high" and "low" passive ankle stiffness. Results The functional ankle instability group exhibited increased motion perception threshold when compared with the corresponding limb of the control group. Between-group differences were not found for passive position sense and passive ankle stiffness. Those in the functional ankle instability group with higher passive ankle stiffness had smaller motion perception thresholds than those with lower passive ankle stiffness. Conclusion Unlike motion perception threshold, passive position sense is not affected by the presence of functional ankle instability. Passive ankle stiffness appears to influence proprioceptive acuity in persons with functional ankle instability. J Orthop Sports Phys Ther 2017;47(12):899-905. Epub 7 Oct 2017. doi:10.2519/jospt.2017.7030.

  20. Color improves “visual” acuity via sound

    OpenAIRE

    Levy-Tzedek, Shelly; Riemer, Dar; Amedi, Amir

    2014-01-01

    Visual-to-auditory sensory substitution devices (SSDs) convey visual information via sound, with the primary goal of making visual information accessible to blind and visually impaired individuals. We developed the EyeMusic SSD, which transforms shape, location, and color information into musical notes. We tested the “visual” acuity of 23 individuals (13 blind and 10 blindfolded sighted) on the Snellen tumbling-E test, with the EyeMusic. Participants were asked to determine the orientation of...

  1. Visual acuity after trans-scleral sutured posterior chamber intraocular lens

    International Nuclear Information System (INIS)

    Mahmood, S.A.; Zafar, S.

    2014-01-01

    To determine the changes in visual acuity in patients undergoing Trans-Scleral Sutured Posterior Chamber Intra-Ocular Lens (TSSPCIOL) implantation at a tertiary care hospital in Karachi, Pakistan. Study Design: Case series. Place and Duration of Study: LRBT Tertiary Eye Hospital, Karachi, from January 2006 to December 2010. Methodology: Records of all patients undergoing implantation of TSSPCIOL were reviewed. Patients with diagnosed glaucoma, diabetic retinopathy, macular degeneration, history of recurrent uveitis, corneal haze or central corneal scars were excluded. For the final analysis, 70 eyes out of a total of 75 were selected. Main outcomes of interest were pre and postoperative visual acuities and surgical complications. SPSS 21 was used for data analysis. Results: Pre-operatively, the average Best Spectacle-Corrected Visual Acuity (BSCVA) was 6/36 on the Snellen chart. This improved to 6/12 postoperatively. The mean improvement seen was 2.4 lines on the Snellen chart (p < 0.05). Complications include transient intraocular pressure elevation in 25 eyes (36%), IOL tilt in 4 eyes (7.1%), Cystoid Macular Edema (CME) in 4 eyes (5.7%), vitreous haemorrhage in 2 eyes (2.9%), hyphema in 2 eyes (2.9%), uveitis in 1 eye (1.4%), and retinal detachment 1 eye (1.4%). No IOL subluxation, suture erosion, iris capture, choroidal effusion or endophthalmitis was encountered and no re-operations were needed. Conclusion: TSSPCIOLs are a good management option for patients with aphakia in whom PC IOLs cannot be placed. (author)

  2. Is theta burst stimulation applied to visual cortex able to modulate peripheral visual acuity?

    Directory of Open Access Journals (Sweden)

    Sabrina Brückner

    Full Text Available Repetitive transcranial magnetic stimulation is usually applied to visual cortex to explore the effects on cortical excitability. Most researchers therefore concentrate on changes of phosphene threshold, rarely on consequences for visual performance. Thus, we investigated peripheral visual acuity in the four quadrants of the visual field using Landolt C optotypes before and after repetitive stimulation of the visual cortex. We applied continuous and intermittend theta burst stimulation with various stimulation intensities (60%, 80%, 100%, 120% of individual phosphene threshold as well as monophasic and biphasic 1 Hz stimulation, respectively. As an important result, no serious adverse effects were observed. In particular, no seizure was induced, even with theta burst stimulation applied with 120% of individual phosphene threshold. In only one case stimulation was ceased because the subject reported intolerable pain. Baseline visual acuity decreased over sessions, indicating a continuous training effect. Unexpectedly, none of the applied transcranial magnetic stimulation protocols had an effect on performance: no change in visual acuity was found in any of the four quadrants of the visual field. Binocular viewing as well as the use of peripheral instead of foveal presentation of the stimuli might have contributed to this result. Furthermore, intraindividual variability could have masked the TMS- induced effects on visual acuity.

  3. Femtosecond-Assisted LASIK Versus PRK: Comparison of 6-Month Visual Acuity and Quality Outcome for High Myopia.

    Science.gov (United States)

    Hashemi, Hassan; Miraftab, Mohammad; Ghaffari, Reza; Asgari, Soheila

    2016-11-01

    To compare the results of femtosecond-assisted laser in situ keratomileusis (femto-LASIK) and photorefractive keratectomy with mitomycin C (PRK-MMC) for the correction of myopia more than 7.0 diopters (D). In this comparative nonrandomized trial, 60 eyes (30 eyes in each group) were enrolled. Patients were tested for uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, ocular and corneal aberrations, and contrast sensitivity (CS) before surgery and at 3 and 6 months postoperatively. Mean preoperative myopia was -8.65±1.51 and -8.04±1.70 D in the femto-LASIK and PRK-MMC groups, respectively (P=0.149). Intergroup differences in baseline indices were not statistically significant. At 6 months after surgery, UDVA showed an improving trend, but it was better in the femto-LASIK group (P=0.026). CDVA in the two groups remained similarly unchanged (P=0.170). For the femto-LASIK and PRK-MMC groups, the safety indices were 1.01±0.05 and 1.01±0.14 (P=0.949), respectively, and the efficacy indices were 0.99±0.07 and 0.93±0.22 (P=0.192), respectively. Comparing CS, only CS18 showed a significantly greater decrease in the femto-LASIK group compared with the PRK-MMC group (P=0.016). Intergroup differences were not statistically significant in other spatial frequencies. Changes in the ocular and corneal higher order aberrations were not statistically different between the two groups except ocular coma, which increased in the femto-LASIK group (P=0.041). Femto-LASIK improves UDVA better than PRK-MMC in high myopia. However, because of increased coma, the quality of vision is reduced. In other words, visual acuity outcome is better with femto-LASIK and visual quality outcome is better with PRK-MMC.

  4. Distinct eye movement patterns enhance dynamic visual acuity

    Science.gov (United States)

    Palidis, Dimitrios J.; Wyder-Hodge, Pearson A.; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics—eye latency, acceleration, velocity gain, position error—and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns—minimizing eye position error, tracking smoothly, and inhibiting reverse saccades—were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA. PMID:28187157

  5. Distinct eye movement patterns enhance dynamic visual acuity.

    Science.gov (United States)

    Palidis, Dimitrios J; Wyder-Hodge, Pearson A; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics-eye latency, acceleration, velocity gain, position error-and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns-minimizing eye position error, tracking smoothly, and inhibiting reverse saccades-were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA.

  6. Evaluating the construct of triage acuity against a set of reference vignettes developed via modified Delphi method.

    Science.gov (United States)

    Twomey, Michèle; Wallis, Lee A; Myers, Jonathan E

    2014-07-01

    To evaluate the construct of triage acuity as measured by the South African Triage Scale (SATS) against a set of reference vignettes. A modified Delphi method was used to develop a set of reference vignettes. Delphi participants completed a 2-round consensus-building process, and independently assigned triage acuity ratings to 100 written vignettes unaware of the ratings given by others. Triage acuity ratings were summarised for all vignettes, and only those that reached 80% consensus during round 2 were included in the reference set. Triage ratings for the reference vignettes given by two independent experts using the SATS were compared with the ratings given by the international Delphi panel. Measures of sensitivity, specificity, associated percentages for over-triage/under-triage were used to evaluate the construct of triage acuity (as measured by the SATS) by examining the association between the ratings by the two experts and the international panel. On completion of the Delphi process, 42 of the 100 vignettes reached 80% consensus on their acuity rating and made up the reference set. On average, over all acuity levels, sensitivity was 74% (CI 64% to 82%), specificity 92% (CI 87% to 94%), under-triage occurred 14% (CI 8% to 23%) and over-triage 12% (CI 8% to 23%) of the time. The results of this study provide an alternative to evaluating triage scales against the construct of acuity as measured with the SATS. This method of using 80% consensus vignettes may, however, systematically bias the validity estimate towards better performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. A comparison of Lea Symbol vs ETDRS letter distance visual acuity in a population of young children with a high prevalence of astigmatism.

    Science.gov (United States)

    Dobson, Velma; Clifford-Donaldson, Candice E; Miller, Joseph M; Garvey, Katherine A; Harvey, Erin M

    2009-06-01

    To compare visual acuity results obtained by use of the Lea Symbols chart with results obtained with Early Treatment Diabetic Retinopathy Study (ETDRS) charts in young children who are members of a population with a high prevalence of astigmatism. Subjects were 438 children ages 5 through 7 years who were enrolled in kindergarten or first grade on the Tohono O'odham Reservation: 241 (55%) had astigmatism >or=1.00 D in one or both eyes (range, 0.00-6.75 D). While wearing best correction, each child had right eye visual acuity tested with the 62 cm by 65 cm Lea Symbols chart at 3 m and with the 62 cm by 65 cm ETDRS chart at 4 m. Visual acuity was scored as the smallest optotype size at which the child correctly identified 3 of a maximum of 5 optotypes. ETDRS visual acuity also was scored based on the total number of letters that the child correctly identified. Correlation between Lea Symbols visual acuity and ETDRS visual acuity was 0.78 (p < 0.001). Mean Lea Symbols visual acuity was one-half line (0.04-0.06 logMAR) better than mean ETDRS visual acuity (p < 0.001). The difference between Lea Symbols and ETDRS visual acuity was not correlated with the mean of the Lea Symbols and ETDRS visual acuity scores, which ranged from -0.3 logMAR (20/10) to 0.74 logMAR (20/110). In this population of young children, in whom the primary source of reduced visual acuity is astigmatism-related amblyopia, the Lea Symbols chart produced visual acuity scores that were about 0.5 line better than visual acuity scores obtained with ETDRS charts.

  8. [Amblyopia: reading speed in comparison with visual acuity for gratings, single Landolt Cs and series Landolt Cs].

    Science.gov (United States)

    Bach, M; Strahl, P; Waltenspiel, S; Kommerell, G

    1990-01-01

    In the treatment of amblyopia in preschool children, a means of predicting later reading ability would be helpful. This prediction might be possible using a test for visual acuity where the results correlate with reading ability in adult patients with amblyopia. We measured the following four parameters in 18 experienced readers with strabismic amblyopia: (1) time spent reading ten lines of a standard text in one of three magnifications, (2) visual acuity for gratings, (3) visual acuity for single Landolt Cs, and (4) visual acuity for crowded Landolt Cs (one Landolt C flanked by two full rings on each side each at a distance of 2.6 min of arc). The reading text was presented on paper at a distance of 40 cm; the subject had a choice of three magnifications. The acuity tests were generated by a computer on a VDU at 4.6 m. The relative impairment of the amblyopic eye was defined as the quotient between the performance of the amblyopic and the good eye. In addition, the difference between the times spent reading the ten lines with the amblyopic and with the good eye was calculated.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Stable Isotopic signatures of Adélie penguin remains provide long-term paleodietary records in Northern Victoria Land (Ross Sea, Antarctica)

    Science.gov (United States)

    Lorenzini, Sandra; Baroni, Carlo; Fallick, Anthony Edward; Baneschi, Ilaria; Salvatore, Maria Cristina; Zanchetta, Giovanni; Dallai, Luigi

    2010-05-01

    The stable isotopes geochemistry of carbon and nitrogen provides a powerful tools for investigating in animal dietary patterns and shifts during the past. The signature of C and N isotopes provide direct information about the diet of an individual and its dietary patterns, especially when the dietary sources consist of prey from different trophic levels (i.e. different C and N isotopic composition) (DeNiro and Epstein 1978, Minawaga and Wada 1984, Koch et al. 1994, Hobson 1995). By analyzing the isotopic composition of penguin remains, we present a new detailed Adélie penguin (Pygoscelis adeliae) paleodietary record for the area of Terra Nova Bay (Victoria Land, Ross Sea). Adélie penguins primarily feed on fish (mainly the silverfish Pleuragramma antarcticum) and krill (Euphausia superba, Euphausia cristallorophias) (Ainley 2002, Lorenzini et al. 2009) that belonging to two different trophic levels. Consequently, they are characterized by different isotopic signatures. Specifically, we analyzed 13C/12C and 15N/14N ratios of more than one thousand of modern and fossil Adélie penguin eggshell and guano samples collected from ornithogenic soils (penguin guano-formed) dated back to ≈7,200 years BP (Baroni and Orombelli 1994, Lambert et al. 2002, Baroni and Hall 2004, Hall et al. 2006). The expanded database of stable isotope values obtained from Adélie penguin remains define a detailed paleodietary record with an excellent temporal continuity over all the investigated time period. Our data indicate a significant dietary shift between fish and krill, with a gradual decrease from past to present time in the proportion of fish compared to krill in Adélie penguin diet. From 7200 yrs BP to 2000 yrs BP, δ13C and δ15N values indicate fish as the most eaten prey. The dietary contribution of lower-trophic prey in penguin diet started becoming evident not earlier than 2000 yrs BP, when the δ13C values reveal a mixed diet based on fish and krill consumption. Modern

  10. Recognition versus Resolution: a Comparison of Visual Acuity Results Using Two Alternative Test Chart Optotype

    Directory of Open Access Journals (Sweden)

    Jonathan S. Pointer

    2008-01-01

    Conclusions: For normally sighted subjects wearing an optimal refractive correction, a bias was recorded in favour of recognition over resolution acuity: the clinical difference amounted to approximately 40% of one logMAR chart line, with similar high repeatability for either chart optotype. We conclude that the assumption of clinical equivalence between letter and Landolt acuity is reasonable under optimum test conditions.

  11. Evaluation of a Public Child Eye Health Tertiary Facility for Pediatric Cataract in Southern Nigeria I: Visual Acuity Outcome

    Science.gov (United States)

    Duke, Roseline E.; Adio, Adedayo; Oparah, Sidney K.; Odey, Friday; Eyo, Okon A.

    2016-01-01

    Purpose: A retrospective study of the outcome of congenital and developmental cataract surgery was conducted in a public child eye health tertiary facility in children <16 years of age in Southern Nigeria, as part of an evaluation. Materials and Method: Manual Small Incision Cataract Surgery with or without anterior vitrectomy was performed. The outcome measures were visual acuity (VA) and change (gain) in visual acuity. The age of the child at onset, duration of delay in presentation, ocular co-morbidity, non ocular co-morbidity, gender, and pre operative visual acuity were matched with postoperative visual acuity. A total of 66 children were studied for a period of six weeks following surgery. Results: Forty eight (72.7%) children had bilateral congenital cataracts and 18 (27.3%) children had bilateral developmental cataracts. There were 38(57.6%) males and 28 (42.4%) females in the study. Thirty Five (53%) children had good visual outcome (normal vision range 6/6/ -6/18) post-operatively. The number of children with blindness (vision <3/60) decreased from 61 (92.4%) pre-operatively to 4 (6.1%) post-operatively. Post operative complication occurred in 6.8% of cases six week after surgery. Delayed presentation had an inverse relationship with change (gain) in visual acuity (r = - 0.342; p-value = 0.005). Pre-operative visual acuity had a positive relationship with post operative change (gain) in visual acuity (r = 0.618; p-value = 0.000). Conclusion: Predictors of change in visual acuity in our study were; delayed presentation and pre-operative VA. Cataract surgery in children showed clinical benefit. PMID:27347247

  12. LASER PHOTOCOAGULATION IN DIABETIC MACULAR EDEMA: EFFECTS ON VISUAL ACUITY AND MACULAR EDEMA

    Directory of Open Access Journals (Sweden)

    M.H. Dehghan

    1999-06-01

    Full Text Available Due to the importance of clinically significant macular edema in diabetic patients, this study is aimed to determine if laser photocoagulation is effective in the treatment of clinically significant diabetic macular edema. In addition, the effects of risk factors arc surveyed* This is an existing data study considering patients with clinically significant diabetic macular edema, treated with argon-green laser photocoagulation in Labbafinejad hospital, department of lasertherapy, from 1995 to 1997. in 60 (42.6% eyes the treatment method was focal, in 22 (15.6% eyes grid, and in 59 (41.84 modified grid laser photocoagulation was performed. The results are based upon deterioration of visual acuity, occurance of moderate visual loss and improvement or persistence of CSME. We studied 114 eyes from 87 patients. Two years after initial treatment, visual acuity improved in 19.1% of eyes, unchanged in 9.5% and worsened in 71.4% of eyes. After this period the rate of moderate visual loss was 28.6% and CSME was improved in 23.8% of eyes. According to our study, baseline visual acuity and retinopathy severity were two important intervening factors in response to lasertherapy. Comparing our results with natural course of diabetic macular edema, indicates that in assessing visual outcome laser photocoagulation is an effective modality in treatment of CSME, but it is not effective in maintaining or improving visual acuity, which is due to patients delay in visiting ophthalmologists and paying not enough attention to follow-up visits.

  13. Visual acuity testing of radiographic inspectors in nondestructive inspection. Final report

    International Nuclear Information System (INIS)

    Yonemura, G.T.

    1981-06-01

    Visual acuity tests for radiographic inspectors should be correlated with the type of tasks encountered in real world radiography. The testing procedures should be capable of assessing differences in day to day performance of a given inspector as well as the performance of one inspector relative to other inspectors. Single line targets with specific parametric values for contrast, width, and blur are recommended to provide a means for testing a radiographic inspector for visual acuity. These targets may be used for periodic tests by the employing organization or for more frequent self testing by the inspector. Statistics from the National Health Survey, procedures recommended by the NAS-NRC Committee on Vision and real world radiographs have been utilized in arriving at recommended test configurations

  14. Visual Acuity is Related to Parafoveal Retinal Thickness in Patients with Retinitis Pigmentosa and Macular Cysts

    Science.gov (United States)

    Brockhurst, Robert J.; Gaudio, Alexander R.; Berson, Eliot L.

    2008-01-01

    Purpose To quantify the prevalence and effect on visual acuity of macular cysts in a large cohort of patients with retinitis pigmentosa. Methods In 316 patients with typical forms of retinitis pigmentosa, we measured visual acuities with Early Treatment Diabetic Retinopathy Study (ETDRS) charts, detected macular cysts with optical coherence tomography (OCT), and quantified retinal thicknesses by OCT. We used the FREQ, LOGISTIC, and GENMOD procedures of SAS to evaluate possible risk factors for cyst prevalence and the MIXED procedure to quantify the relationships of visual acuity to retinal thickness measured at different locations within the macula. Results We found macular cysts in 28% of the patients, 40% of whom had cysts in only one eye. Macular cysts were seen most often in patients with dominant disease and not at all in patients with X-linked disease (p = 0.006). In eyes with macular cysts, multiple regression analysis revealed that visual acuity was inversely and independently related to retinal thickness at the foveal center (p = 0.038) and within a ring spanning an eccentricity of 5° to 10° from the foveal center (p = 0.004). Conclusions Macular cysts are a common occurrence in retinitis pigmentosa, especially among patients with dominantly-inherited disease. Visual acuity is influenced by edema in the parafovea, as well as in the fovea. PMID:18552390

  15. [The influence of IOL implantation on visual acuity, contrast sensitivity and colour vision 2 and 4 months after cataract surgery].

    Science.gov (United States)

    Ventruba, J

    2006-04-01

    To assess the change in visual acuity, contrast sensitivity and colour vision in relation to the time after cataract surgery and to the type of implanted IOL, and to compare visual functions by patients with one and two pseudophakic eyes. 45 cataract patients were examined before and then 2 and 4 month after the cataract surgery. Visual acuity (VA) was tested on logMAR optotype chart with Landolt rings, contrast sensitivity (CS) was tested on the Pelli-Robson chart and the SWCT chart. For colour vision (CV) testing, the standard Farnsworth D-15 test and the desaturated Lanthony D-15 test were used. The patients were divided into two groups--a group with one pseudophakic eye and a group with two pseudophakic eyes, and also according to the type of IOL--PMMA or hydrophobic acrylate that had been implanted. Control group was composed of phakic subjects with no ocular pathology. After the cataract surgery, in both groups there was a significant improvement in monocular and binocular VA (p test (p test (p tested by means of psychophysical methods of VA, CS and CV significantly improve and are stable 2 month after the surgery. The second eye surgery improves binocular visual functions the level of which doesn't differ from that of normal phakic subjects. There was no influence of the type of IOL on final state of VA, CS or CV.

  16. Socio-Demographic Factors Associated With Loss Of Visual Acuity ...

    African Journals Online (AJOL)

    The study was designed to identify the sociodemographic factors, which significantly affect the visual acuity of glaucoma patients at presentation. It is a prospective study of 154 new patients with a diagnosis of primary open angle glaucoma seen over 1 year and 8 months at the eye clinic of the University of Benin Teaching ...

  17. A new dynamic visual acuity test to assess peripheral vestibular function.

    Science.gov (United States)

    Vital, Domenic; Hegemann, Stefan C A; Straumann, Dominik; Bergamin, Oliver; Bockisch, Christopher J; Angehrn, Dominik; Schmitt, Kai-Uwe; Probst, Rudolf

    2010-07-01

    To evaluate a novel test for dynamic visual acuity (DVA) that uses an adaptive algorithm for changing the size of Landolt rings presented during active or passive head impulses, and to compare the results with search-coil head impulse testing. Prospective study in healthy individuals and patients with peripheral vestibular deficits. Tertiary academic center. One hundred neuro-otologically healthy individuals (age range, 19-80 years) and 15 patients with bilateral (n = 5) or unilateral (n = 10) peripheral vestibular loss (age range, 27-72 years). Testing of static visual acuity (SVA), DVA during active and passive horizontal head rotations (optotype presentation at head velocities >100 degrees/s and >150 degrees/s), and quantitative horizontal head impulse testing with scleral search coils. Difference between SVA and DVA, that is, visual acuity loss (VA loss), gain of the high-acceleration vestibulo-ocular reflex. Passive head impulses and higher velocities were more effective than active impulses and lower velocities. Using passive head impulses and velocities higher than 150 degrees/s, the DVA test discriminated significantly (P test sensitivity was 100%, specificity was 94%, and accuracy was 95%, with search-coil head impulse testing used as a reference. In healthy individuals, VA loss increased significantly with age (P testing with Landolt rings that are adaptively changed in size enables detection of peripheral vestibular dysfunction in a fast and simple way.

  18. The influence of tongue strength on oral viscosity discrimination acuity.

    Science.gov (United States)

    Steele, Catriona M

    2018-06-01

    The ability to generate tongue pressures is widely considered to be critical for liquid bolus propulsion in swallowing. It has been proposed that the application of tongue pressure may also serve the function of collecting sensory information regarding bolus viscosity (resistance to flow). In this study, we explored the impact of age-related reductions in tongue strength on oral viscosity discrimination acuity. The experiment employed a triangle test discrimination protocol with an array of xanthan-gum thickened liquids in the mildly to moderately thick consistency range. A sample of 346 healthy volunteers was recruited, with age ranging from 12 to 86 (164 men, 182 women). On average, participants were able to detect a 0.29-fold increase in xanthan-gum concentration, corresponding to a 0.5-fold increase in viscosity at 50/s. Despite having significantly reduced tongue strength on maximum isometric tongue-palate pressure tasks, and regardless of sex, older participants in this study showed no reductions in viscosity discrimination acuity. In this article, the relationship between tongue strength and the ability to discriminate small differences in liquid viscosity during oral processing is explored. Given that tongue strength declines with age in healthy adults and is also reduced in individuals with dysphagia, it is interesting to determine whether reduced tongue strength might contribute to difficulties in evaluating liquid viscosity during the oral stage of swallowing. Using an array of mildly to moderately thick xanthan-gum thickened liquids, this experiment failed to find any evidence that reductions in tongue strength influence oral viscosity discrimination acuity. © 2017 Wiley Periodicals, Inc.

  19. Diagnosing cerebral visual impairment in children with good visual acuity.

    Science.gov (United States)

    van Genderen, Maria; Dekker, Marjoke; Pilon, Florine; Bals, Irmgard

    2012-06-01

    To identify elements that could facilitate the diagnosis of cerebral visual impairment (CVI) in children with good visual acuity in the general ophthalmic clinic. We retrospectively investigated the clinical characteristics of 30 children with good visual acuity and CVI and compared them with those of 23 children who were referred with a suspicion of CVI, but proved to have a different diagnosis. Clinical characteristics included medical history, MRI findings, visual acuity, crowding ratio (CR), visual field assessment, and the results of ophthalmologic and orthoptic examination. We also evaluated the additional value of a short CVI questionnaire. Eighty-three percent of the children with an abnormal medical history (mainly prematurity and perinatal hypoxia) had CVI, in contrast with none of the children with a normal medical history. Cerebral palsy, visual field defects, and partial optic atrophy only occurred in the CVI group. 41% of the children with CVI had a CR ≥2.0, which may be related to dorsal stream dysfunction. All children with CVI, but also 91% of the children without CVI gave ≥3 affirmative answers on the CVI questionnaire. An abnormal pre- or perinatal medical history is the most important risk factor for CVI in children, and therefore in deciding which children should be referred for further multidisciplinary assessment. Additional symptoms of cerebral damage, i.e., cerebral palsy, visual field defects, partial optic atrophy, and a CR ≥2 may support the diagnosis. CVI questionnaires should not be used for screening purposes as they yield too many false positives.

  20. A comparison of behavioural (Landolt C) and anatomical estimates of visual acuity in archerfish (Toxotes chatareus).

    Science.gov (United States)

    Temple, S E; Manietta, D; Collin, S P

    2013-05-03

    Archerfish forage by shooting jets of water at insects above the water's surface. The challenge of detecting small prey items against a complex background suggests that they have good visual acuity, but to date this has never been tested, despite archerfish becoming an increasingly important model species for vertebrate vision. We used a modified Landolt C test to measure visual acuity behaviourally, and compared the results to their predicted minimum separable angle based on both photoreceptor and ganglion cell spacing in the retina. Both measures yielded similar estimates of visual acuity; between 3.23 and 3.57 cycles per degree (0.155-0.140° of visual arc). Such a close match between behavioural and anatomical estimates of visual acuity in fishes is unusual and may be due to our use of an ecologically relevant task that measured the resolving power of the part of the retina that has the highest photoreceptor density and that is used in aligning their spitting angle with potential targets. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Visual acuity and visual skills in Malaysian children with learning disabilities

    Directory of Open Access Journals (Sweden)

    Muzaliha MN

    2012-09-01

    Full Text Available Mohd-Nor Muzaliha,1 Buang Nurhamiza,1 Adil Hussein,1 Abdul-Rani Norabibas,1 Jaafar Mohd-Hisham-Basrun,1 Abdullah Sarimah,2 Seo-Wei Leo,3 Ismail Shatriah11Department of Ophthalmology, 2Biostatistics and Research Methodology Unit, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia; 3Paediatric Ophthalmology and Strabismus Unit, Department of Ophthalmology, Tan Tock Seng Hospital, SingaporeBackground: There is limited data in the literature concerning the visual status and skills in children with learning disabilities, particularly within the Asian population. This study is aimed to determine visual acuity and visual skills in children with learning disabilities in primary schools within the suburban Kota Bharu district in Malaysia.Methods: We examined 1010 children with learning disabilities aged between 8–12 years from 40 primary schools in the Kota Bharu district, Malaysia from January 2009 to March 2010. These children were identified based on their performance in a screening test known as the Early Intervention Class for Reading and Writing Screening Test conducted by the Ministry of Education, Malaysia. Complete ocular examinations and visual skills assessment included near point of convergence, amplitude of accommodation, accommodative facility, convergence break and recovery, divergence break and recovery, and developmental eye movement tests for all subjects.Results: A total of 4.8% of students had visual acuity worse than 6/12 (20/40, 14.0% had convergence insufficiency, 28.3% displayed poor accommodative amplitude, and 26.0% showed signs of accommodative infacility. A total of 12.1% of the students had poor convergence break, 45.7% displayed poor convergence recovery, 37.4% showed poor divergence break, and 66.3% were noted to have poor divergence recovery. The mean horizontal developmental eye movement was significantly prolonged.Conclusion: Although their visual acuity was satisfactory, nearly 30% of the

  2. Quantifying inter-laboratory variability in stable isotope analysis of ancient skeletal remains.

    Directory of Open Access Journals (Sweden)

    William J Pestle

    Full Text Available Over the past forty years, stable isotope analysis of bone (and tooth collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond, the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a sample preparation, and b analysis (instrumentation, working standards, and data calibration. Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration. These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite

  3. Quantifying inter-laboratory variability in stable isotope analysis of ancient skeletal remains.

    Science.gov (United States)

    Pestle, William J; Crowley, Brooke E; Weirauch, Matthew T

    2014-01-01

    Over the past forty years, stable isotope analysis of bone (and tooth) collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond), the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a) sample preparation, and b) analysis (instrumentation, working standards, and data calibration). Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration). These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite isotope values

  4. Comparing performance on the MNREAD iPad application with the MNREAD acuity chart.

    Science.gov (United States)

    Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E

    2018-01-01

    Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials.

  5. The correlation between variation of visual acuity and the anterior chamber depth in the early period after phacoemulsification

    Directory of Open Access Journals (Sweden)

    Kai-jian CHEN

    2011-04-01

    Full Text Available Objective To investigate the correlation between the visual acuity variation and the anterior chamber depth in the early period after phacoemulsification.Methods Thirty-six eyes of 32 patients with age-related cataract underwent 3.2mm clear corneal incision phacoemulsification and intraocular lens(IOL implantation.The visual acuity was examined and horizontal curvature(K1,vertical curvature(K2,corneal astigmatism,and anterior chamber depth were measured with IOL-master preoperatively and also on 1,3,7 and 15 postoperative days.The changes in parameters were compared,and the correlations among visual acuity,corneal astigmatism and anterior chamber depth were analyzed.Results Before operation and 1d,3d,7d and 15d after operation,the corneal astigmatism was-0.87±0.40D,-1.92±1.38D,-1.69±1.13D,-1.45±0.79D and-1.36±0.74D;the anterior chamber depth was 3.08±0.35mm,4.04±0.38mm,4.28±0.29mm,4.22±0.17mm and 4.22±0.16mm;the visual acuity was 0.18±0.10,0.44±0.14,0.59±0.12,0.61±0.11 and 0.62±0.14.Significant difference was found between pre-operative and postoperative visual acuity,corneal astigmatism and anterior chamber depth,and it was also found in corneal astigmatism between 1d and 15d post operation(P < 0.05,as well as in anterior chamber depth and visual acuity between 1d and 3d post operation(P < 0.05.A positive correlation was found between visual acuity and corneal astigmatism on 1d(r=0.42,P < 0.05,3d(r=0.35,P < 0.05 and 7d(r=0.35,P < 0.05 post operation;and a negative correlation was found between visual acuity and anterior chamber depth on 3d(r=-0.29,P < 0.05,7d(r=-0.43,P < 0.01 and 15d(r=-0.37,P < 0.05 post operation.Conclusion Both the corneal astigmatism and the anterior chamber depth are correlated with the visual acuity variation in the early period after phacoemulsification.

  6. Effect of pupil size on visual acuity in a laboratory model of pseudophakic monovision.

    Science.gov (United States)

    Kawamorita, Takushi; Uozato, Hiroshi; Handa, Tomoya; Ito, Misae; Shimizu, Kimiya

    2010-05-01

    To investigate the effect of pupil size on visual acuity in pseudophakic monovision. For the simulation, a modified Liou-Brennan model eye was used. The model eye was designed to include a centered optical system, corneal asphericity, an iris pupil, a Stiles-Crawford effect, an intraocular lens, and chromatic aberration. Calculation of the modulation transfer function (MTF) was performed with ZEMAX software. Visual acuity was estimated from the MTF and the retinal threshold curve. The sizes of the entrance pupil were 2.0, 2.5, 3.0, and 4.0 mm. Decreasing pupil diameter and increasing myopia progressively improved near visual acuity. For an entrance pupil size of 2.5 mm and a refractive error of -1.50 diopters, the logMAR value (Snellen; metric) in the non-dominant eye at 40 cm was 0.06 (20/23; 6/6.9). Knowledge of the patient's pupil diameter at near fixation can assist surgeons in determining the optimum degree of myopia for successful monovision.

  7. Posterior staphyloma in oculocutaneous albinism: another possible cause of reduced visual acuity.

    Science.gov (United States)

    Lee, Susan; Schimmenti, Lisa A; King, Richard A; Brilliant, Murray; Anderson, Jennifer L; Schoonveld, Cheri; Summers, C Gail

    2015-12-01

    Posterior staphyloma is typically associated with myopic degeneration and has not been recognized as a cause of reduced visual acuity in albinism. We report 3 cases of posterior staphyloma, each with oculocutaneous albinism (OCA) defined by phenotype and genotype. Two cases are biological sisters with OCA type 2; one was myopic and the other was hyperopic. The third case involves a man with OCA associated with Hermansky-Pudlak syndrome (HPS-5). Staphyloma may be another cause of reduced visual acuity in albinism, particularly with increasing age. It may occur in association with myopia or hyperopia. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  8. Dynamic Visual Acuity and Landing Sickness in Crewmembers Returning from Long-Duration Spaceflight

    Science.gov (United States)

    Rosenberg, M.J.F; Peters, B.T.; Reschke, M. F.

    2016-01-01

    Long-term exposure to microgravity causes sensorimotor adaptations that result in functional deficits upon returning to a gravitational environment. At landing the vestibular system and the central nervous system, responsible for coordinating head and eye movements, are adapted to microgravity and must re-adapt to the gravitational environment. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with astronauts reporting oscillopsia and blurred vision. Dynamic visual acuity (DVA) is assessed using an oscillating chair developed in the Neuroscience Laboratory at JSC. This chair is lightweight and easily portable for quick deployment in the field. The base of the chair is spring-loaded and allows for manual oscillation of the subject. Using a metronome, the chair is vertically oscillated plus or minus 2 cm at 2 Hz by an operator, to simulate walking. While the subject is being oscillated, they are asked to discern the direction of Landolt-C optotypes of varying sizes and record their direction using a gamepad. The visual acuity thresholds are determined using an algorithm that alters the size of the optotype based on the previous response of the subject using a forced-choice best parameter estimation that is able to rapidly converge on the threshold value. Visual acuity thresholds were determined both for static (seated) and dynamic (oscillating) conditions. Dynamic visual acuity is defined as the difference between the dynamic and static conditions. Dynamic visual acuity measures will be taken prior to flight (typically L-180, L-90, and L-60) and up to eight times after landing, including up to 3 times on R plus 0. Follow up measurements will be taken at R plus 1 (approximately 36 hours after landing). Long-duration International Space Station crewmembers will be tested once at the refueling stop in Europe and once again upon return to Johnson Space Center. In addition to DVA, subjective ratings of motion sickness will be recorded

  9. Fractionated Stereotactic Radiotherapy in Patients With Optic Nerve Sheath Meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Paulsen, Frank, E-mail: frank.paulsen@med.uni-tuebingen.de [Department of Radiation Oncology, University of Tuebingen, Tuebingen (Germany); Doerr, Stefan [Department of Radiation Oncology, University of Tuebingen, Tuebingen (Germany); Wilhelm, Helmut [Department of Ophthalmology, University of Tuebingen, Tuebingen (Germany); Becker, Gerd [Department of Radiation Oncology, Klinik am Eichert, Goeppingen (Germany); Bamberg, Michael [Department of Radiation Oncology, University of Tuebingen, Tuebingen (Germany); Classen, Johannes [Department of Radiation Oncology, St. Vincentius-Kliniken, Karlsruhe (Germany)

    2012-02-01

    Purpose: To evaluate the effectiveness of fractionated stereotactic radiotherapy (SFRT) in the treatment of optic nerve sheath meningioma (ONSM). Methods and Materials: Between 1993 and 2005, 109 patients (113 eyes) with primary (n = 37) or secondary (n = 76) ONSM were treated according to a prospective protocol with SFRT to a median dose of 54 Gy. All patients underwent radiographic, ophthalmologic, and endocrine analysis before and after SFRT. Radiographic response, visual control, and late side effects were endpoints of the analysis. Results: Median time to last clinical, radiographic, and ophthalmologic follow up was 30.2 months (n = 113), 42.7 months (n = 108), and 53.7 months (n = 91), respectively. Regression of the tumor was observed in 5 eyes and progression in 4 eyes, whereas 104 remained stable. Visual acuity improved in 12, deteriorated in 11, and remained stable in 68 eyes. Mean visual field defects reduced from 33.6% (n = 90) to 17.8% (n = 56) in ipsilateral and from 10% (n = 94) to 6.7% (n = 62) in contralateral eyes. Ocular motility improved in 23, remained stable in 65, and deteriorated in 3 eyes. Radiographic tumor control was 100% at 3 years and 98% at 5 years. Visual acuity was preserved in 94.8% after 3 years and in 90.9% after 5 years. Endocrine function was normal in 90.8% after 3 years and in 81.3% after 5 years. Conclusions: SFRT represents a highly effective treatment for ONSM. Interdisciplinary counseling of the patients is recommended. Because of the high rate of preservation of visual acuity we consider SFRT the standard approach for the treatment of ONSM. Prolonged observation is warranted to more accurately assess late visual impairment. Moderate de-escalation of the radiation dose might improve the preservation of visual acuity and pituitary gland function.

  10. Impact of colour in the assessment of potential visual acuity in patients with age-related macular degeneration.

    Science.gov (United States)

    Dorrepaal, Stephen J; Markowitz, Samuel N

    2013-06-01

    To compare chromatic and achromatic potential visual acuity (PVA) in patients with bilateral low vision caused by age-related macular degeneration (AMD). Prospective, nonrandomized, observational case series. Fifty-five patients, representing a consecutive series of patients all presenting with bilateral AMD. Best-corrected visual acuity of each eye was measured using an Early Treatment in Diabetic Retinopathy Study (ETDRS) chart with appropriate near correction. Included were cases with visual acuity of 0.4 logMAR (20/50) or worse in both eyes. Achromatic and chromatic PVA were measured in each eye using white on black and red on yellow flooding E charts at 50 cm in controlled lighting conditions. One hundred and seven eyes from 55 patients were included in the analysis. Mean achromatic and chromatic PVA were 0.69 ± 0.26 and 0.65 ± 0.22 logMAR, respectively. Overall, patients had a significantly higher chromatic than achromatic PVA, with a median difference of 0.1 logMAR (p<0.05). Patients with ETDRS visual acuity worse than 0.9 logMAR also had a significantly higher chromatic than achromatic PVA, with a median difference of 0.1 logMAR (p<0.05). Patients with ETDRS visual acuity between 0.4 and 0.9 logMAR had a trend toward a higher chromatic than achromatic visual acuity that was not significant, with a median difference of 0.1 logMAR (p = 0.8539). Patients with low vision caused by AMD can discern smaller targets when a red on yellow colour scheme is used than when using achromatic white on black charts. Copyright © 2013 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  11. A Demonstration Project on Driving with Reduced Visual Acuity and a Bioptic Telescope System in the Netherlands

    NARCIS (Netherlands)

    Melis-Dankers, Bart J.M.; Kooijman, Aart C.; Brouwer, Wiebo H.; Busscher, Rens B.; Bredewoud, Ruud A.; Derksen, Peter H.; Amersfoort, Anoeska; IJsseldijk, Martin A.M.; Delden, Geert W. van; Grotenhuis, Thea H.P.A.; Witvliet, M.D.

    2008-01-01

    Background: In Europe, driving a passenger car is prohibited if binocular best corrected visual acuity (BCVA) is below 0.5 (20/40). Some US states allow people with reduced visual acuity to use a bioptic telescope system when driving. The aim of our study is to introduce a bioptic telescope system

  12. Correlation between contrast sensitivity and visual acuity in retinitis pigmentosa patients.

    Science.gov (United States)

    Akeo, Kiyoshi; Hiida, Yoshiki; Saga, Masamichi; Inoue, Rikako; Oguchi, Yoshihisa

    2002-01-01

    High-contrast figures such as Landolt rings are insufficient to evaluate the function of the foveal cones of retinitis pigmentosa (RP) patients. We investigated the correlation between visual function as determined with Landolt rings and with the Vistech Contrast Sensitivity Function Test (VCTS) at various spatial frequencies, in addition to the Cambridge Low Contrast Grating (CLCG). The study included 30 retinitis pigmentosa patients (53 eyes). All patients were assessed with Landolt rings, the Vistech method, and the CLCG. We estimated the relative contribution of contrast sensitivity to visual acuity by VCTS at each spatial frequency and by CLCG by simple linear regression analysis. The results of the regression analysis of VCTS at 1.5, 3.0, and 6.0 cycles/degree showed a significant correlation between Landolt rings and VCTS and between CLCG and VCTS that was strongest at 6.0 cycles/degree. There was no significant correlation between Landolt rings and VCTS or between CLCG and VCTS at 12.0 and 18.0 cycles/degree. Patients with a visual acuity of 20/25 and CLCG greater than 100 were divided into two groups according to their contrast sensitivity at 18.0 cycles/degree on VCTS. The VCTS at the highest frequency was useful for evaluating the foveal visual function in RP patients having good visual acuity with the Landolt rings. Thus, contrast sensitivity should be useful in detecting minute impairment or improvement of visual function in RP. Copyright 2002 S. Karger AG, Basel

  13. Perceptual learning in children with visual impairment improves near visual acuity.

    Science.gov (United States)

    Huurneman, Bianca; Boonstra, F Nienke; Cox, Ralf F A; van Rens, Ger; Cillessen, Antonius H N

    2013-09-17

    This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four- to nine-year-old children with visual impairment. Participants were 45 children with visual impairment and 29 children with normal vision. Children with visual impairment were divided into three groups: a magnifier group (n = 12), a crowded perceptual learning group (n = 18), and an uncrowded perceptual learning group (n = 15). Children with normal vision also were divided in three groups, but were measured only at baseline. Dependent variables were single near visual acuity (NVA), crowded NVA, LH line 50% crowding NVA, number of trials, accuracy, performance time, amount of small errors, and amount of large errors. Children with visual impairment trained during six weeks, two times per week, for 30 minutes (12 training sessions). After training, children showed significant improvement of NVA in addition to specific improvements on the training task. The crowded perceptual learning group showed the largest acuity improvements (1.7 logMAR lines on the crowded chart, P children in the crowded perceptual learning group showed improvements on all NVA charts. Children with visual impairment benefit from perceptual training. While task-specific improvements were observed in all training groups, transfer to crowded NVA was largest in the crowded perceptual learning group. To our knowledge, this is the first study to provide evidence for the improvement of NVA by perceptual learning in children with visual impairment. (http://www.trialregister.nl number, NTR2537.).

  14. Vision-guided ocular growth in a mutant chicken model with diminished visual acuity.

    Science.gov (United States)

    Ritchey, Eric R; Zelinka, Christopher; Tang, Junhua; Liu, Jun; Code, Kimberly A; Petersen-Jones, Simon; Fischer, Andy J

    2012-09-01

    Visual experience is known to guide ocular growth. We tested the hypothesis that vision-guided ocular growth is disrupted in a model system with diminished visual acuity. We examine whether ocular elongation is influenced by form-deprivation (FD) and lens-imposed defocus in the Retinopathy, Globe Enlarged (RGE) chicken. Young RGE chicks have poor visual acuity, without significant retinal pathology, resulting from a mutation in guanine nucleotide-binding protein β3 (GNB3), also known as transducin β3 or Gβ3. The mutation in GNB3 destabilizes the protein and causes a loss of Gβ3 from photoreceptors and ON-bipolar cells (Ritchey et al., 2010). FD increased ocular elongation in RGE eyes in a manner similar to that seen in wild-type (WT) eyes. By comparison, the excessive ocular elongation that results from hyperopic defocus was increased, whereas myopic defocus failed to significantly decrease ocular elongation in RGE eyes. Brief daily periods of unrestricted vision interrupting FD prevented ocular elongation in RGE chicks in a manner similar to that seen in WT chicks. Glucagonergic amacrine cells differentially expressed the immediate early gene Egr1 in response to growth-guiding stimuli in RGE retinas, but the defocus-dependent up-regulation of Egr1 was lesser in RGE retinas compared to that of WT retinas. We conclude that high visual acuity, and the retinal signaling mediated by Gβ3, is not required for emmetropization and the excessive ocular elongation caused by FD and hyperopic defocus. However, the loss of acuity and Gβ3 from RGE retinas causes enhanced responses to hyperopic defocus and diminished responses to myopic defocus. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Visual acuity measures do not reliably detect childhood refractive error--an epidemiological study.

    Directory of Open Access Journals (Sweden)

    Lisa O'Donoghue

    Full Text Available PURPOSE: To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. METHODS: The Northern Ireland Childhood Errors of Refraction (NICER study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. RESULTS: Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. CONCLUSIONS: Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver.

  16. Microactuator production via high aspect ratio, high edge acuity metal fabrication technology

    Science.gov (United States)

    Guckel, H.; Christenson, T. R.

    1993-01-01

    LIGA is a procession sequence which uses x-ray lithography on photoresist layers of several hundred micrometers to produce very high edge acuity photopolymer molds. These plastic molds can be converted to metal molds via electroplating of many different metals and alloys. The end results are high edge acuity metal parts with large structural heights. The LIGA process as originally described by W. Ehrfeld can be extended by adding a surface micromachining phase to produce precision metal parts which can be assembled to form three-dimensional micromechanisms. This process, SLIGA, has been used to fabricate a dynamometer on a chip. The instrument has been fully implemented and will be applied to tribology issues, speed-torque characterization of planar magnetic micromotors and a new family of sensors.

  17. Progressive improvement of impaired visual acuity during the first year after transsphenoidal surgery for non-functioning pituitary macroadenoma

    NARCIS (Netherlands)

    Dekkers, O. M.; de Keizer, R. J. W.; Roelfsema, F.; Vd Klaauw, A. A.; Honkoop, P. J.; van Dulken, H.; Smit, J. W. A.; Romijn, J. A.; Pereira, A. M.

    2007-01-01

    Improvement of visual field defects continues even years after the initial surgical treatment. Because this process of continuing improvement has not been documented for visual acuity, we audited our data to explore the pattern of recovery of visual acuity until 1 year after transsphenoidal surgery

  18. Normative monocular visual acuity for early treatment diabetic retinopathy study charts in emmetropic children 5 to 12 years of age.

    Science.gov (United States)

    Dobson, Velma; Clifford-Donaldson, Candice E; Green, Tina K; Miller, Joseph M; Harvey, Erin M

    2009-07-01

    To provide normative data for children tested with Early Treatment Diabetic Retinopathy Study (ETDRS) charts. Cross-sectional study. A total of 252 Native American (Tohono O'odham) children aged 5 to 12 years. On the basis of cycloplegic refraction conducted on the day of testing, all were emmetropic (myopia < or =0.25 diopter [D] spherical equivalent, hyperopia < or =1.00 D spherical equivalent, and astigmatism < or =0.50 D in both eyes). Monocular visual acuity was tested at 4 m, using 1 ETDRS chart for the right eye (RE) and another for the left eye (LE). Visual acuity was scored as the total number of letters correctly identified, by naming or matching to letters on a lap card, and as the smallest letter size for which the child identified 3 of 5 letters correctly. Visual acuity results did not differ for the RE versus the LE, so data are reported for the RE only. Mean visual acuity for 5-year-olds (0.16 logarithm of the minimum angle of resolution [logMAR] [20/29]) was significantly worse than for 8-, 9-, 10-, 11-, and 12-year-olds (0.05 logMAR [20/22] or better at each age). The lower 95% prediction limit for determining whether a child has visual acuity within the normal range was 0.38 (20/48) for 5-year-olds and 0.30 (20/40) for 6- to 12-year-olds, which was reduced to 0.32 (20/42) for 5-year-olds and 0.21 (20/32) for 6- to 12-year-olds when recalculated with outlying data points removed. Mean interocular acuity difference did not vary by age, averaging less than 1 logMAR line at each age, with a lower 95% prediction limit of 0.17 log unit (1.7 logMAR lines) across all ages. For monocular visual acuity based on ETDRS charts to be in the normal range, it must be better than 20/50 for 5-year-olds and better than 20/40 for 6- to 12-year-olds. Normal interocular acuity difference includes values of less than 2 logMAR lines. Normative ETDRS visual acuity values are not as good as norms reported for adults, suggesting that a child's visual acuity results should

  19. Remain stable.; Schoen stabil bleiben.

    Energy Technology Data Exchange (ETDEWEB)

    Teroerde, Michael; Schulz, Detlef [Helmut-Schmidt-Univ., Hamburg (Germany). Professur fuer Elektrische Energiesysteme; Eckoldt, Hans-Joerg [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Fachgebiet Magnetstromversorgung

    2013-11-15

    In the German power grid the increasing photovoltaic power plants and wind turbines provide due to their volatile energy supply high demands on the control of the power grid. In the case of malfunctions in the network short-term energy storage could participate in the grid control. Superconducting magnetic energy storage (SMES) belongs to the efficient short-term energy storage. A SMES system was investigated at DESY in Hamburg. [German] Im deutschen Stromnetz stellen die zunehmenden Photovoltaik- und Windkraftanlagen aufgrund ihrer stark schwankenden Energieeinspeisung hohe Anforderungen an die Regelung des Stromnetzes. Bei eventuell auftretenden Stoerungen im Netz koennten Kurzzeitenergiespeicher an der Netzregelung teilnehmen. Zu den effizienten Kurzzeitspeichern gehoeren supraleitende magnetische Energiespeicher (SMES). Ein SMES-System wurde bei DESY in Hamburg untersucht.

  20. Perceptual Learning in Children With Visual Impairment Improves Near Visual Acuity

    NARCIS (Netherlands)

    Huurneman, Bianca; Boonstra, F. Nienke; Cox, Ralf F. A.; van Rens, Ger; Cillessen, Antonius H. N.

    PURPOSE. This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four-to nine-year-old children with visual impairment. METHODS. Participants were 45 children with visual impairment and 29 children with normal vision. Children

  1. Perceptual Learning in Children With Visual Impairment Improves Near Visual Acuity

    NARCIS (Netherlands)

    Huurneman, B.; Boonstra, F.N.; Cox, R.F.A.; van Rens, G.H.M.B.; Cillessen, A.H.N.

    2013-01-01

    Purpose. This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four- to nine-year-old children with visual impairment. Methods. Participants were 45 children with visual impairment and 29 children with normal vision. Children

  2. Perceptual learning in children with visual impairment improves near visual acuity

    NARCIS (Netherlands)

    Huurneman, B.; Boonstra, F.N.; Cox, R.F.; Rens, G. van; Cillessen, A.H.

    2013-01-01

    PURPOSE: This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four- to nine-year-old children with visual impairment. METHODS: Participants were 45 children with visual impairment and 29 children with normal vision. Children

  3. Perceptual Learning in Children With Visual Impairment Improves Near Visual Acuity

    NARCIS (Netherlands)

    Huurneman, B.; Boonstra, F.N.; Cox, R.F.A.; Rens, G.H.M.B. van; Cillessen, A.H.N.

    2013-01-01

    PURPOSE. This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four-to nine-year-old children with visual impairment. METHODS. Participants were 45 children with visual impairment and 29 children with normal vision. Children

  4. EXAMINATION OF THE VISUAL ACUITY ON THE LCD OPTOTYPE WITH WHOLE-LINE AND INTERPOLATION METHOD

    OpenAIRE

    Zajíček Tomáš; Veselý Petr; Veselý Petr; Synek Svatopluk; Synek Svatopluk

    2012-01-01

    The goal of this work is to show the possibility of us using the LCD optotype in common optometrist practice. Furthermore two commonly used methods for measuring visual acuity will be compared. 69 respondents were used for the measurements. The respondents were divided into two groups according to the measured LCD optotype. The visual acuity was measured using the whole-line method on modified Snellen charts as well as the interpolation method on ETDRS charts. Measurements were taken on the S...

  5. Levels of acute phase proteins remain stable after ischemic stroke

    Directory of Open Access Journals (Sweden)

    Paik Myunghee C

    2006-10-01

    Full Text Available Abstract Background Inflammation and inflammatory biomarkers play an important role in atherosclerosis and cardiovascular disease. Little information is available, however, on time course of serum markers of inflammation after stroke. Methods First ischemic stroke patients ≥40 years old had levels of high-sensitivity C-reactive protein (hsCRP, serum amyloid A (SAA, and fibrinogen measured in plasma samples drawn at 1, 2, 3, 7, 14, 21 and 28 days after stroke. Levels were log-transformed as needed, and parametric and non-parametric statistical tests were used to test for evidence of a trend in levels over time. Levels of hsCRP and SAA were also compared with levels in a comparable population of stroke-free participants. Results Mean age of participants with repeated measures (n = 21 was 65.6 ± 11.6 years, and 13 (61.9% were men, and 15 (71.4% were Hispanic. Approximately 75% of patients (n = 15 had mild strokes (NIH Stroke Scale score 0–5. There was no evidence of a time trend in levels of hsCRP, SAA, or fibrinogen for any of the markers during the 28 days of follow-up. Mean log(hsCRP was 1.67 ± 1.07 mg/L (median hsCRP 6.48 mg/L among stroke participants and 1.00 ± 1.18 mg/L (median 2.82 mg/L in a group of 1176 randomly selected stroke-free participants from the same community (p = 0.0252. Conclusion Levels of hsCRP are higher in stroke patients than in stroke-free subjects. Levels of inflammatory biomarkers associated with atherosclerosis, including hsCRP, appear to be stable for at least 28 days after first ischemic stroke.

  6. Visual outcome in cystic craniopharyngiomas treated with intracavitary phosphorus-32

    International Nuclear Information System (INIS)

    Anderson, D.R.; Trobe, J.D.; Taren, J.A.; Gebarski, S.S.

    1989-01-01

    Seven patients with cystic craniopharyngiomas were treated with stereotactic instillation of radioactive phosphorus-32 (32P). Five patients had been previously treated with various combinations of surgery and external beam irradiation, whereas two had the 32 P instillation as a primary therapy. Visual acuity improved in 13 eyes and remained stable in 1. Visual fields normalized in three patients, improved in two, and remained stable in two. Two patients received single treatments with 32 P, whereas five required multiple instillations for recurrent cyst expansion

  7. RISK FOR LOW VISUAL ACUITY AFTER 1 AND 2 YEARS OF TREATMENT WITH RANIBIZUMAB OR BEVACIZUMAB FOR PATIENTS WITH NEOVASCULAR AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    Westborg, Inger; Albrecht, Susanne; Rosso, Aldana

    2017-11-01

    To investigate how patients with neovascular age-related macular degeneration treated with ranibizumab or bevacizumab respond to treatment in daily clinical practice. Data from the Swedish Macula Register on the treatment received by 3,912 patients during 2011 to 2014 is reported. Patients' characteristics at the first visit, visual acuity, number of injections, and reason for terminating the treatment if applicable are discussed. Furthermore, the risk of having poor vision (visual acuity under 60 Early Treatment Diabetes Retinopathy Study letters or approximately 20/60 Snellen) is calculated for the treated eye after 1 year and 2 years. The treatment outcome depends on the visual acuity at the first visit. For patients with visual acuity more than 60 letters, the risk of having a visual acuity lower than 60 letters after 1 year or 2 years of treatment is approximately 20%. However, for patients with low visual acuity at diagnosis (fewer than 60 letters), the risk is approximately 60%. The risk of having a visual acuity lower than 60 letters does not depend on the choice of treatment drug. Treatment with anti-vascular endothelial growth factor intravitreal injections mainly maintains the visual acuity level, and only approximately 20% and 40% of the patients required vision rehabilitation after 1 year and 2 years, respectively.

  8. A randomised comparison between an inexpensive, general-purpose headlight and a purpose-built surgical headlight on users' visual acuity and colour vision.

    Science.gov (United States)

    Street, I; Sayles, M; Nistor, M; McRae, A R

    2014-02-01

    To determine if there are any differences in near visual acuity and colour vision between an inexpensive general-purpose light emitting diode (LED) headlight and a purpose-built surgical LED headlight. A prospective study was conducted sequentially comparing near visual acuity and colour vision, the headlights being tested in random order, in a testing room with a constant minimal amount of background light. The participants were NHS employee volunteers, with self-declared normal (or corrected) vision, working in occupations requiring full literacy. For visual acuity, outcome was measured by recording the smallest font legible when using each headlight when the subject read a near visual acuity test card. For colour vision, the outcome was passing or failing the Ishihara test. There was no statistically significant difference between the general-purpose and the purpose-built headlights in users' near visual acuity or colour vision.

  9. Temporal acuity and speech recognition score in noise in patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Mehri Maleki

    2014-04-01

    Full Text Available Background and Aim: Multiple sclerosis (MS is one of the central nervous system diseases can be associated with a variety of symptoms such as hearing disorders. The main consequence of hearing loss is poor speech perception, and temporal acuity has important role in speech perception. We evaluated the speech perception in silent and in the presence of noise and temporal acuity in patients with multiple sclerosis.Methods: Eighteen adults with multiple sclerosis with the mean age of 37.28 years and 18 age- and sex- matched controls with the mean age of 38.00 years participated in this study. Temporal acuity and speech perception were evaluated by random gap detection test (GDT and word recognition score (WRS in three different signal to noise ratios.Results: Statistical analysis of test results revealed significant differences between the two groups (p<0.05. Analysis of gap detection test (in 4 sensation levels and word recognition score in both groups showed significant differences (p<0.001.Conclusion: According to this survey, the ability of patients with multiple sclerosis to process temporal features of stimulus was impaired. It seems that, this impairment is important factor to decrease word recognition score and speech perception.

  10. Lrit1, a Retinal Transmembrane Protein, Regulates Selective Synapse Formation in Cone Photoreceptor Cells and Visual Acuity

    Directory of Open Access Journals (Sweden)

    Akiko Ueno

    2018-03-01

    Full Text Available Summary: In the vertebrate retina, cone photoreceptors play crucial roles in photopic vision by transmitting light-evoked signals to ON- and/or OFF-bipolar cells. However, the mechanisms underlying selective synapse formation in the cone photoreceptor pathway remain poorly understood. Here, we found that Lrit1, a leucine-rich transmembrane protein, localizes to the photoreceptor synaptic terminal and regulates the synaptic connection between cone photoreceptors and cone ON-bipolar cells. Lrit1-deficient retinas exhibit an aberrant morphology of cone photoreceptor pedicles, as well as an impairment of signal transmission from cone photoreceptors to cone ON-bipolar cells. Furthermore, we demonstrated that Lrit1 interacts with Frmpd2, a photoreceptor scaffold protein, and with mGluR6, an ON-bipolar cell-specific glutamate receptor. Additionally, Lrit1-null mice showed visual acuity impairments in their optokinetic responses. These results suggest that the Frmpd2-Lrit1-mGluR6 axis regulates selective synapse formation in cone photoreceptors and is essential for normal visual function. : Ueno et al. finds that Lrit1 plays an important role in regulating the synaptic connection between cone photoreceptors and cone ON-bipolar cells. The Frmpd2-Lrit1-mGluR6 axis is crucial for selective synapse formation in cone photoreceptors and for development of normal visual function. Keywords: retina, circuit, synapse formation, cone photoreceptor cell, ON-bipolar cell, visual acuity

  11. A new Snellen's visual acuity chart with 'Indian' numerals.

    OpenAIRE

    Al-Salem, M

    1987-01-01

    'Indian' numerals, which are popular among the Arab population, were used to devise a new Snellen's visual acuity chart. The new chart has the advantages of a reading chart. It keeps the patient's interest, does not miss alexic patients, and is quicker to perform. It is also devoid of the many disadvantages of a kinetic response chart (the capital E letter or Landolt's broken rings), especially that of the limited option of test objects.

  12. Changes in smell acuity induced by radiation exposure of the olfactory mucosa

    International Nuclear Information System (INIS)

    Ophir, D.; Guterman, A.; Gross-Isseroff, R.

    1988-01-01

    The effects of ionizing radiation on smell acuity were assessed in 12 patients in whom the olfactory mucosa was exposed to radiation in the course of treatment for nasopharyngeal carcinoma or pituitary adenoma. Olfactory detection thresholds for two odorants (amyl acetate and eugenol) were determined before the start of radiation therapy, within a week of termination of therapy, and 1, 3, and 6 months later. The results show clearly that smell acuity is profoundly affected by therapeutic irradiation. Thresholds had increased in all 12 patients by the end of treatment and were still high one month later. Varying degrees of recovery were noted in most patients three to six months after cessation of treatment. The fate of the sense of smell deserves more attention when considering the disability caused by irradiation to certain head and neck tumors

  13. Astronauts Cooper and Conrad prepare cameras during visual acuity tests

    Science.gov (United States)

    1965-01-01

    Astronauts L. Gordon Cooper Jr. (left), command pilot, and Charles Conrad Jr., pilot, the prime crew of the Gemini 5 space flight, prepare their cameras while aboard a C-130 aircraft flying near Laredo. The two astronauts are taking part in a series of visual acuity experiments to aid them in learning to identify known terrestrial features under controlled conditions.

  14. Visual acuity at 10 years in Cryotherapy for Retinopathy of Prematurity (CRYO-ROP) study eyes: effect of retinal residua of retinopathy of prematurity.

    Science.gov (United States)

    Dobson, Velma; Quinn, Graham E; Summers, C Gail; Hardy, Robert J; Tung, Betty

    2006-02-01

    To describe recognition (letter) acuity at age 10 years in eyes with and without retinal residua of retinopathy of prematurity (ROP). Presence and severity of ROP residua were documented by a study ophthalmologist. Masked testers measured monocular recognition visual acuity (Early Treatment of Diabetic Retinopathy Study) when the children were 10 years old. Two hundred forty-seven of 255 surviving Cryotherapy for Retinopathy of Prematurity (CRYO-ROP) randomized trial patients participated. A reference group of 102 of 104 Philadelphia-based CRYO-ROP study participants who did not develop ROP was also tested. More severe retinal residua were associated with worse visual acuity, regardless of whether retinal ablation was performed to treat the severe acute-phase ROP. However, within each ROP residua category, there was a wide range of visual acuity results. This is the first report of the relation between visual acuity (Early Treatment of Diabetic Retinopathy Study charts) and structural abnormalities related to ROP in a large group of eyes that developed threshold ROP in the perinatal period. Visual deficits are greater in eyes with more severe retinal residua than in eyes with mild or no residua. However, severity of ROP residua does not predict the visual acuity of an individual eye because within a single residua category, acuity may range from near normal to blind.

  15. Sensorimotor posture control in the blind: superior ankle proprioceptive acuity does not compensate for vision loss.

    Science.gov (United States)

    Ozdemir, Recep A; Pourmoghaddam, Amir; Paloski, William H

    2013-09-01

    To better understand sensorimotor posture control differences between blind and sighted individuals, we examined the role of ankle joint proprioception and ankle muscle strength on postural control in healthy blind (n=13, 25-58 years) and age- and sex-matched sighted (n=15, 20-65 years) volunteers. We measured ankle joint proprioceptive acuity and isokinetic muscle strength in plantarflexion and dorsiflexion using an isokinetic dynamometer. We also assessed postural control performance during quiet bipedal stance with and without sudden postural perturbations, and during quiet unipedal stance. We found that while our blind subjects exhibited significantly better proprioceptive acuity than our sighted subjects their postural control performance was significantly poorer than that of the sighted group with eyes open, and no different from that of the sighted group with eyes closed suggesting that their superior proprioceptive acuity does not translate to improved balance control. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Influences of multiple memory systems on auditory mental image acuity.

    Science.gov (United States)

    Navarro Cebrian, Ana; Janata, Petr

    2010-05-01

    The influence of different memory systems and associated attentional processes on the acuity of auditory images, formed for the purpose of making intonation judgments, was examined across three experiments using three different task types (cued-attention, imagery, and two-tone discrimination). In experiment 1 the influence of implicit long-term memory for musical scale structure was manipulated by varying the scale degree (leading tone versus tonic) of the probe note about which a judgment had to be made. In experiments 2 and 3 the ability of short-term absolute pitch knowledge to develop was manipulated by presenting blocks of trials in the same key or in seven different keys. The acuity of auditory images depended on all of these manipulations. Within individual listeners, thresholds in the two-tone discrimination and cued-attention conditions were closely related. In many listeners, cued-attention thresholds were similar to thresholds in the imagery condition, and depended on the amount of training individual listeners had in playing a musical instrument. The results indicate that mental images formed at a sensory/cognitive interface for the purpose of making perceptual decisions are highly malleable.

  17. Gains following perceptual learning are closely linked to the initial visual acuity.

    Science.gov (United States)

    Yehezkel, Oren; Sterkin, Anna; Lev, Maria; Levi, Dennis M; Polat, Uri

    2016-04-28

    The goal of the present study was to evaluate the dependence of perceptual learning gains on initial visual acuity (VA), in a large sample of subjects with a wide range of VAs. A large sample of normally sighted and presbyopic subjects (N = 119; aged 40 to 63) with a wide range of uncorrected near visual acuities (VA, -0.12 to 0.8 LogMAR), underwent perceptual learning. Training consisted of detecting briefly presented Gabor stimuli under spatial and temporal masking conditions. Consistent with previous findings, perceptual learning induced a significant improvement in near VA and reading speed under conditions of limited exposure duration. Our results show that the improvements in VA and reading speed observed following perceptual learning are closely linked to the initial VA, with only a minor fraction of the observed improvement that may be attributed to the additional sessions performed by those with the worse VA.

  18. Influence of head posture on the visual acuity of children with nystagmus

    Directory of Open Access Journals (Sweden)

    Ana Carla Ramos Vieira da Costa

    2014-01-01

    Full Text Available Purpose: Evaluate the relationship between the postural alignment of the head and possible interference in the view of children. Methods: We evaluated 11 children between 2 and 7 years of age of both sexes, with the visually impaired, who had nystagmus and head lock position. The test Lea Grating Acuity Test® was used to collect measurements of visual acuity. This applied on two occasions: with and without postural alignment of the head. For reliability of the postural alignment of the head, the slopes were measured by Fisiologic® software. Results: The children had a poorer performance after physiological postural alignment. This poor performance is possible due to loss of position lock nystagmus to gain postural alignment, said to be ideal. Postural compensations were observed, and sharply increased eyestrain. Conclusion: The pursuit of traditional postural alignment affect the visual response of children with visual impairments.

  19. Outcome of visual acuity after surgical removal of pituitary adenomas

    Directory of Open Access Journals (Sweden)

    Grković Desanka

    2013-01-01

    Full Text Available Introduction. Pituitary adenomas with suprasellar extension may produce anterior visual pathway compression, resulting in characteristic visual deficit. Surgical decompression of these structures prevents further visual deterioration and its postop­ erative recovery. Objective. The aim of this study was to investigate pre­ and postoperative visual acuity (VA in patients with pituitary ad­ enomas, and to detect the influence of prognostic factors, such as symptoms duration, degree of visual acuity reduction and tumor size in the assessment of the prognosis of postoperative visual function. Methods. We analyzed 40 consecutive patients who fulfilled three criteria: evidence of preoperative visual dysfunction, transsphenoidal or transfrontal tumor resection and hystologically verified pituitary adenoma. A visual examination was performed under standard conditions, pre and postoperatively (10 days, one month and six months after surgery. A paired t­test was used to assess the differences of pre­ and postoperative characteristics values, and the Chisquare test of independence in the assessment of the influence of prognostic factors. Results. Postoperative improvement of VA was seen in 84.61% patients (68% eyes. Eyes with preoperative mild and moderate degree of VA reduction showed improvement in 89.65% eyes in contrast to 22.60% eyes with preoperative severe reduction of VA, which was all statistically significant. Eyes in patients with tumor smaller than 20 mm had improvement of VA in 91.66% eyes, while eyes with tumor larger than 40 mm had improvement of VA in 61.11% eyes, which was statistically significant. When symptoms duration was below two years the improvement of VA was detected in 65.38% eyes as related to 50% eyes with symptoms duration exceeding two years, which was not statistically significant. Conclusion. Pituitary adenomas commonly cause visual impairment. Postoperatively the majority of patients show a distinct improvement of

  20. Short-term visual deprivation does not enhance passive tactile spatial acuity.

    Directory of Open Access Journals (Sweden)

    Michael Wong

    Full Text Available An important unresolved question in sensory neuroscience is whether, and if so with what time course, tactile perception is enhanced by visual deprivation. In three experiments involving 158 normally sighted human participants, we assessed whether tactile spatial acuity improves with short-term visual deprivation over periods ranging from under 10 to over 110 minutes. We used an automated, precisely controlled two-interval forced-choice grating orientation task to assess each participant's ability to discern the orientation of square-wave gratings pressed against the stationary index finger pad of the dominant hand. A two-down one-up staircase (Experiment 1 or a Bayesian adaptive procedure (Experiments 2 and 3 was used to determine the groove width of the grating whose orientation each participant could reliably discriminate. The experiments consistently showed that tactile grating orientation discrimination does not improve with short-term visual deprivation. In fact, we found that tactile performance degraded slightly but significantly upon a brief period of visual deprivation (Experiment 1 and did not improve over periods of up to 110 minutes of deprivation (Experiments 2 and 3. The results additionally showed that grating orientation discrimination tends to improve upon repeated testing, and confirmed that women significantly outperform men on the grating orientation task. We conclude that, contrary to two recent reports but consistent with an earlier literature, passive tactile spatial acuity is not enhanced by short-term visual deprivation. Our findings have important theoretical and practical implications. On the theoretical side, the findings set limits on the time course over which neural mechanisms such as crossmodal plasticity may operate to drive sensory changes; on the practical side, the findings suggest that researchers who compare tactile acuity of blind and sighted participants should not blindfold the sighted participants.

  1. Motor function declines over time in human immunodeficiency virus and is associated with cerebrovascular disease, while HIV-associated neurocognitive disorder remains stable.

    Science.gov (United States)

    M Elicer, Isabel; Byrd, Desiree; Clark, Uraina S; Morgello, Susan; Robinson-Papp, Jessica

    2018-04-25

    HIV-associated neurocognitive disorders (HAND) remain prevalent in the combined antiretroviral therapy (CART) era, especially the milder forms. Despite these milder phenotypes, we have shown that motor abnormalities persist and have quantified them with the HIV Dementia Motor Scale (HDMS). Our objectives were to replicate, in an independent sample, our prior findings that the HDMS is associated with cognitive impairment in HIV, while adding consideration of age-associated comorbidities such as cerebrovascular disease, and to examine the longitudinal trajectories of cognitive and motor dysfunction. We included all participants enrolled in the Manhattan HIV Brain Bank (MHBB) from January 2007 to May 2017 who had complete baseline data (N = 164). MHBB participants undergo standardized longitudinal assessments including documentation of comorbidities and medications, blood work, the HDMS, and neurocognitive testing. We found that motor dysfunction, cognitive impairment, and cerebrovascular disease were significantly associated with each other at baseline. Cerebrovascular disease independently predicted cognitive impairment in a multivariable model. Longitudinal analysis in a subset of 78 participants with ≥ 4 years of follow-up showed a stable cognition but declining motor function. We conclude that the HDMS is a valid measurement of motor dysfunction in HIV-infected patients and is associated with cognitive impairment and the presence of cerebrovascular disease. Cognitive impairment is mild and stable in CART-treated HIV; however, motor function declines over time, which may be related to the accrual of comorbidities such as cerebrovascular disease. Further research should examine the mechanisms underlying motor dysfunction in HIV and its clinical impact.

  2. Effect of occlusion amblyopia after prescribed full-time occlusion on long-term visual acuity outcomes.

    Science.gov (United States)

    Longmuir, Susannah; Pfeifer, Wanda; Scott, William; Olson, Richard

    2013-01-01

    To investigate the incidence and characteristics of occlusion amblyopia with prescribed full-time patching and determine its effect on long-term visual acuity outcomes. The records of patients younger than 10 years diagnosed as having amblyopia between 1970 and 2000 were retrospectively reviewed. Patients were prescribed full-time occlusion and observed until completion of therapy. Of 597 patients treated for amblyopia by full-time patching, 115 were diagnosed as having occlusion amblyopia (19.3%). Seventy-five percent (86 of 115) developed occlusion amblyopia during the first episode of full-time patching. Occlusion amblyopia occurred more frequently in children prescribed full-time patching at an earlier age (P = .0002), with an odds ratio of 8.56 (95% confidence interval: 2.73, 26.84) in children younger than 36 months and 2.66 (95% confidence interval: 0.96, 7.37) in children between 36 and 59 months old. Seven of the patients with occlusion amblyopia did not reverse fixation and continued to fixate with the initially amblyopic eye after treatment. Final visual acuity in these eyes with occlusion amblyopia was 20/30 or better. After cessation of treatment, the final interocular difference in visual acuity was less in patients with a history of occlusion amblyopia (P = .003). Occlusion amblyopia occurred at all ages, but the incidence decreased with increasing age. Patients who developed occlusion amblyopia with prescribed full-time occlusion had less interocular visual acuity difference than patients who did not, suggesting that development of occlusion amblyopia can indicate the potential for the development of better vision in the originally amblyopic eye. Copyright 2013, SLACK Incorporated.

  3. Visual Acuity Improvement of Amblyopia in an Adult With Levodopa/Carbidopa Treatment.

    Science.gov (United States)

    Orge, Faruk H; Dar, Suhail A

    2015-09-09

    Amblyopia is the leading cause of visual loss in children, affecting 2% to 3% of the population. Occlusion of the dominant eye is the primary and best treatment, although efficacy decreases after 6 years of age. As a result, levodopa/carbidopa has been explored as an adjunct to conventional therapy and has been shown to have an immediate impact on visual acuity. Several studies to date have shown mixed results on the benefit of supplementing occlusion therapy with levodopa/carbidopa, although they have primarily studied children. The authors describe the oldest patient (46 years old) documented in the literature to have shown improvement in visual acuity using levodopa/carbidopa. He was given a 16-week course at a dose in line with previous studies while being effectively occluded full time due to a glaucomatous right eye with no light perception. On 3-month follow-up, his left eye improved two lines and stabilized at 6 months. Copyright 2015, SLACK Incorporated.

  4. Near-field visual acuity of pigeons: effects of head location and stimulus luminance.

    Science.gov (United States)

    Hodos, W; Leibowitz, R W; Bonbright, J C

    1976-03-01

    Two pigeons were trained to discriminate a grating stimulus from a blank stimulus of equivalent luminance in a three-key chamber. The stimuli and blanks were presented behind a transparent center key. The procedure was a conditional discrimination in which pecks on the left key were reinforced if the blank had been present behind the center key and pecks on the right key were reinforced if the grating had been present behind the center key. The spatial frequency of the stimuli was varied in each session from four to 29.5 lines per millimeter in accordance with a variation of the method of constant stimuli. The number of lines per millimeter that the subjects could discriminate at threshold was determined from psychometric functions. Data were collected at five values of stimulus luminance ranging from--0.07 to 3.29 log cd/m2. The distance from the stimulus to the anterior nodal point of the eye, which was determined from measurements taken from high-speed motion-picture photographs of three additional pigeons and published intraocular measurements, was 62.0 mm. This distance and the grating detection thresholds were used to calculate the visual acuity of the birds at each level of luminance. Acuity improved with increasing luminance to a peak value of 0.52, which corresponds to a visual angle of 1.92 min, at a luminance of 2.33 log cd/m2. Further increase in luminance produced a small decline in acuity.

  5. Evaluation of a visual acuity test using closed Landolt-Cs to determine malingering.

    Science.gov (United States)

    Kröger, Nils; Jürgens, Clemens; Kohlmann, Thomas; Tost, Frank

    2017-12-01

    To evaluate a visual acuity test (VAT) with unexpected optotypes to detect malingering. We tested two groups. Group 1 consisted of 20 individuals with normal best corrected visual acuity (BCVA). Group 2 included participants with ocular diseases and reduced BCVA. All subjects underwent a VAT proposed by Gräf and Roesen to assess suspected malingering. This test used 36 charts with one Landolt-C per page. The first 20 optotypes were Landolt-Cs, while at positions 21, 26, 30, and 34 closed rings were presented. The testing distance was adapted to 50% of the test person's visual acuity. The test person was requested to name the gap direction of the Landolt-C within 3 s. The complete testing conversation was recorded digitally to determine response latency for each optotype from the audio tracks. The average response time was 0.46 s in group 1 and 0.45 s in group 2 for the first 20 Landolt-Cs. In both groups the response time was significantly extended (p ring compared to the mean of the first 20 Landolt-Cs, (group 1: 2.9 s; group 2: 2.3 s). The following three closed rings had also longer response times. However, these differences were not significant. Our results suggest that the proposed test may be helpful to evaluate ocular malingering. The testing procedure appeared to be feasible and showed good repeatability. The fast training effect may be a limitation for malingering detection.

  6. Changes in brain morphology in albinism reflect reduced visual acuity.

    Science.gov (United States)

    Bridge, Holly; von dem Hagen, Elisabeth A H; Davies, George; Chambers, Claire; Gouws, Andre; Hoffmann, Michael; Morland, Antony B

    2014-07-01

    Albinism, in humans and many animal species, has a major impact on the visual system, leading to reduced acuity, lack of binocular function and nystagmus. In addition to the lack of a foveal pit, there is a disruption to the routing of the nerve fibers crossing at the optic chiasm, resulting in excessive crossing of fibers to the contralateral hemisphere. However, very little is known about the effect of this misrouting on the structure of the post-chiasmatic visual pathway, and the occipital lobes in particular. Whole-brain analyses of cortical thickness in a large cohort of subjects with albinism showed an increase in cortical thickness, relative to control subjects, particularly in posterior V1, corresponding to the foveal representation. Furthermore, mean cortical thickness across entire V1 was significantly greater in these subjects compared to controls and negatively correlated with visual acuity in albinism. Additionally, the group with albinism showed decreased gyrification in the left ventral occipital lobe. While the increase in cortical thickness in V1, also found in congenitally blind subjects, has been interpreted to reflect a lack of pruning, the decreased gyrification in the ventral extrastriate cortex may reflect the reduced input to the foveal regions of the ventral visual stream. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. VISUAL ABILITY IN AMBLYOPIC CHILDREN COMPARED TO CHILDREN WITH NORMAL VISUAL ACUITY

    Directory of Open Access Journals (Sweden)

    Zorica Tončić

    2016-03-01

    Full Text Available Vision rehabilitation in adults with low vision, even in children, is achieved with special devices, called low vision aids, LVA. The aim of the study is to determine the degree of visual function in amblyopic children and daily activities that are best related to those of normally sighted peers with normal visual acuity. The subjects were divided into two groups, matched 1:1 by age and gender: the first group consisted of 19 amblyopic children, and the second one consisted of 19 children with normal visual acuity. The questionnaire used to assess visual ability was Cardiff Visual Ability Questionnaire for Children (CVAQC, a reliable instrument for measuring visual ability in children with low vision. The study was conducted in the only rehabilitation center for amblyopic children in this region, so this is also a pioneer study. The overall result of CVAQC in amblyopic children was 1.287 log vs.-2.956, representing statistically significantly poorer visual ability in comparison to peers without vision deficit (p˂0.005. Amblyopic children function best in entertainment activities, especially in listening music (-2.31 log; as for sport, these children report swimming to be their favourite activity (-0.99 log. In the field of education they show best results in language acquisition (-0.79 log and the worst in mathematics (3.13 log. The greatest problem is reading small print texts books (2.61 log. Low vision children have poorer result of visual function in comparison to their peers with normal visual acuity. A precise deficit assessment in the most important spheres of life can be determined by using the questionnaires, so the rehabilitation can be rightly chosen.

  8. Macular Structures, Optical Components, and Visual Acuity in Preschool Children after Intravitreal Bevacizumab or Laser Treatment.

    Science.gov (United States)

    Lee, Yung-Sung; See, Lai-Chu; Chang, Shu-Hao; Wang, Nan-Kai; Hwang, Yih-Shiou; Lai, Chi-Chun; Chen, Kuan-Jen; Wu, Wei-Chi

    2018-05-10

    To investigate the macular structures, optical components, and visual acuity in preschool-aged children with a history of type I retinopathy of prematurity who underwent either intravitreal bevacizumab (IVB), laser, or a combination of treatments. Comparative interventional case series. A referred medical center in Taiwan. 80 eyes from 42 patients (33 IVB-treated eyes from 17 children, 24 laser-treated eyes from 13 children, and 23 laser + IVB-treated eyes from 12 children). Spectral-domain optical coherence tomography. The retinal thickness in the foveal area and the associated morphologic changes in foveal depression. Compared with the laser-treated and laser + IVB-treated eyes, the IVB-treated eyes had less myopia and deeper anterior chamber depths but presented similar axial lengths and corneal curvatures (P = .001, .002, .95 and .16, respectively). The IVB-treated eyes had significantly thinner foveal, parafoveal, and perifoveal retinal thicknesses (P < .01 for all) and a higher incidence of foveal depression than the laser- or laser + IVB-treated eyes. The macular and subfoveal choroidal thicknesses did not differ among the groups (P = .21 and .63, respectively). Moreover, compared with the eyes treated with laser or laser + IVB, the IVB-treated eyes had better uncorrected visual acuity, although a significant difference was not observed in best-corrected visual acuity (P = .008 and .29, respectively). Compared with laser therapy, IVB-treated eyes were associated with deeper anterior chamber depths and thinner foveal, parafoveal and perifoveal thicknesses. Moreover, these IVB-treated eyes had less refractive errors and better uncorrected visual acuity. Copyright © 2018. Published by Elsevier Inc.

  9. Low-level laser therapy improves visual acuity in adolescent and adult patients with amblyopia.

    Science.gov (United States)

    Ivandic, Boris T; Ivandic, Tomislav

    2012-03-01

    The purpose of this study was to examine the effects of low-level laser therapy (LLLT) on visual acuity in adolescent and adult patients with amblyopia. Currently, amblyopia can be treated successfully only in children. In this single-blinded, placebo-controlled study, 178 patients (mean age 46.8 years) with amblyopia caused by ametropia (110 eyes) or strabismus (121 eyes) were included. For LLLT, the area of the macula was irradiated through the conjunctiva from 1 cm distance for 30 sec with laser light (780 nm, 292 Hz, 1:1 duty cycle; average power 7.5 mW; spot area 3 mm(2)). The treatment was repeated on average 3.5 times, resulting in a mean total dose of 0.77 J/cm(2). No occlusion was applied, and no additional medication was administered. Best corrected distant visual acuity was determined using Snellen projection optotypes. In 12 patients (12 eyes), the multifocal visual evoked potential (M-VEP) was recorded. A control group of 20 patients (20 eyes) received mock treatment. Visual acuity improved in ∼90% of the eyes treated with LLLT (pamblyopia caused by ametropia and strabismus, respectively. The treatment effect was maintained for at least 6 months. The mean M-VEP amplitude increased by 1207 nV (pamblyopia caused by ametropia or strabismus.

  10. Effect of neodymium:YAG laser capsulotomy on visual function in patients with posterior capsule opacification and good visual acuity.

    Science.gov (United States)

    Yotsukura, Erisa; Torii, Hidemasa; Saiki, Megumi; Negishi, Kazuno; Tsubota, Kazuo

    2016-03-01

    To evaluate the effect of neodymium:YAG (Nd:YAG) laser capsulotomy on the visual function in patients with posterior capsule opacification (PCO) and good visual acuity. Keio University Hospital, Tokyo, Japan. Observational case series. Eyes were evaluated that had previous cataract surgery with a clinical diagnosis of PCO requiring Nd:YAG laser capsulotomy regardless of a good corrected distance visual acuity (CDVA) (at least 20/20). The CDVA, 10% low contrast visual acuity (LCVA), wavefront aberrations from the 3rd to 6th order, and retinal straylight were measured before and after Nd:YAG laser capsulotomy. The study included 16 eyes of 16 patients (10 men, 6 women; mean age 69.5 years ± 9.3 [SD]). The mean CDVA, LCVA, and straylight after Nd:YAG laser capsulotomy improved significantly (P The root mean square (RMS) of the 3rd Zernike coefficients (S3) and the RMS of the total higher-order aberrations (HOAs) from the 3rd to 6th order decreased significantly after capsulotomy (P The straylight correlated significantly with the total HOAs (r = 0.727, P = .002) and S3 (r = 0.748, P = .001) before capsulotomy. Subjective symptoms resolved after capsulotomy in all cases. Neodymium:YAG laser capsulotomy enabled a significant improvement in visual function even in patients with PCO with good visual acuity. Straylight measurements might be useful to determine the indications for Nd:YAG laser capsulotomy when patients report visual disturbances without decreased visual acuity. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Método computadorizado para medida da acuidade visual A computerized method for visual acuity assessment

    Directory of Open Access Journals (Sweden)

    Patrícia Katayama Kjaer Arippol

    2006-12-01

    Full Text Available OBJETIVO: Elaborar e validar teste computadorizado para medida da acuidade visual de escolares. MÉTODOS: Foi elaborado teste computadorizado para determinação da acuidade visual utilizando os padrões das tabelas logarítmicas impressas adotadas na clínica oftalmológica. Foram avaliados 90 alunos da primeira série do ensino básico, oito estudantes do curso de Tecnologia Oftálmica da UNIFESP-EPM e 10 pacientes do ambulatório de Estrabismo do Departamento de Oftalmologia da UNIFESP-EPM. Todos os sujeitos foram avaliados pelo mesmo examinador e submetidos ao exame de acuidade visual monocular, pela tabela logarítmica de optotipos E impressa e do novo teste computadorizado no mesmo momento. Os participantes forneceram os seus consentimentos após esclarecimento. RESULTADOS: As análises estatísticas revelaram correlação excelente (r>0,75 entre os dois métodos, apesar da leve tendência apresentada pelo teste computadorizado em superestimar a acuidade visual quando comparado com o padrão-ouro. O teste computadorizado apresentou sensibilidade de 100% e especificidade de 94%. CONCLUSÕES: Os resultados obtidos nos permitem dizer que o teste computadorizado pode ser utilizado como novo recurso para triagem da qualidade visual dos escolares, por ser método rápido, de fácil aplicação, barato, automático e atrativo para as crianças. A automatização desvincula o aplicador da interpretação das respostas dadas pelo aluno testado, garante padronização do procedimento, que favorece as análises de acompanhamento e pode ser realizado por diferentes examinadores. Para melhor compreensão da efetividade do teste como instrumento de triagem visual, seria interessante instituí-lo nas escolas do curso básico, após treinamento dos professores para sua aplicação.PURPOSE: To elaborate and to validate a computerized test for visual acuity screening of school-age children. METHODS: We have created a computerized test for visual acuity

  12. The Microcirculation is Preserved in Emergency Department Low‐acuity Sepsis Patients Without Hypotension

    DEFF Research Database (Denmark)

    Skibsted, Simon; Filbin, Michael; Hou, Peter

    2014-01-01

    -acuity sepsis patients. The hypothesis was that patients with sepsis, but without hypotension, will demonstrate signs of flow abnormalities compared to noninfected control patients. Methods This was a prospective, observational study in a convenience sample of patients with sepsis and noninfected controls...

  13. Switching from pro re nata to treat-and-extend regimen improves visual acuity in patients with neovascular age-related macular degeneration.

    Science.gov (United States)

    Kvannli, Line; Krohn, Jørgen

    2017-11-01

    To evaluate the visual outcome after transitioning from a pro re nata (PRN) intravitreal injection regimen to a treat-and-extend (TAE) regimen for patients with neovascular age-related macular degeneration (AMD). A retrospective review of patients who were switched from a PRN regimen with intravitreal injections of bevacizumab, ranibizumab or aflibercept to a TAE regimen. The best corrected visual acuity (BCVA), central retinal thickness (CRT) and type of medication used at baseline, at the time of changing treatment regimen and at the end of the study were analysed. Twenty-one eyes of 21 patients met the inclusion criteria. Prior to the switch, the patients received a mean of 13.8 injections (median, 10; range, 3-39 injections) with the PRN regimen for 44 months (range, 3-100 months), which improved the visual acuity in five patients (24%). After a mean of 6.1 injections (median, 5; range, 3-14 injections) with the TAE regimen over 8 months (range, 2-16 months), the visual acuity improved in 12 patients (57%). The improvement in visual acuity during treatment with the TAE regimen was statistically significant (p = 0.005). The proportion of patients with a visual acuity of 0.2 or better was significantly higher after treatment with the TAE regimen than after treatment with the PRN regimen (p = 0.048). No significant differences in CRT were found between the two treatment regimens. Even after prolonged treatment and a high number of intravitreal injections, switching AMD patients from a PRN regimen to a strict TAE regimen significantly improves visual acuity. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. Infants in Drug Withdrawal: A National Description of Nurse Workload, Infant Acuity, and Parental Needs.

    Science.gov (United States)

    Smith, Jessica G; Rogowski, Jeannette A; Schoenauer, Kathryn M; Lake, Eileen T

    Infants in drug withdrawal have complex physiological and behavioral states, requiring intensive nursing care. The study objectives were to describe acuity, parental needs, and nurse workload of infants in drug withdrawal compared with other infants. The design was cross-sectional and involved secondary nurse survey data from 6045 staff nurses from a national sample of 104 neonatal intensive care units. Nurses reported the care of 15 233 infants, 361 (2.4%) of whom were in drug withdrawal. Three-fourths of hospitals had at least 1 infant in drug withdrawal. In these hospitals, the mean number of infants in drug withdrawal was 4.7. Infant acuity was significantly higher among infants in drug withdrawal. Parents of infants in drug withdrawal required significantly more care to address complex social situations (51% vs 12%). The number of infants assigned to nurses with at least 1 infant in withdrawal (mean = 2.69) was significantly higher than typical (mean = 2.51). Given infant acuity and parental needs, policies legislating patient-to-nurse ratios should permit professional discretion on the number of patients to assign nurses caring for infants in drug withdrawal. Managers and charge nurses should consider the demands of caring for infants in drug withdrawal in assignment decisions and provide support and education.

  15. Does Knee Osteoarthritis Differentially Modulate Proprioceptive Acuity in the Frontal and Sagittal Planes of the Knee?

    Science.gov (United States)

    Cammarata, Martha L; Schnitzer, Thomas J; Dhaher, Yasin Y

    2012-01-01

    Objective Impaired proprioception may alter joint loading and contribute to the progression of knee osteoarthritis (OA). Though frontal plane loading at the knee contributes to OA, proprioception and its modulation with OA in this direction have not been examined. The aim of this study was to assess knee proprioceptive acuity in the frontal and sagittal planes in knee OA and healthy participants. We hypothesized that proprioceptive acuity will be decreased in the OA population in both planes of movement. Methods Thirteen persons with knee OA and fourteen healthy age-matched subjects participated. Proprioceptive acuity was assessed in varus, valgus, flexion, and extension using the threshold to detection of passive movement (TDPM). Repeated measures analysis of variance was used to assess differences in TDPM between subject groups and across movement directions. Linear regression analyses were performed to assess the correlation of TDPM between and within planes of movement. Results TDPM was found to be significantly higher (Pplanes of movement were only weakly correlated, especially in the OA group. Conclusions Consistent differences in TDPM between the OA and control groups across all movement directions suggest a global, not direction-specific, reduction in sensation in knee OA patients. PMID:21547895

  16. Effect of ocular transverse chromatic aberration on detection acuity for peripheral vision.

    Science.gov (United States)

    Cheney, Frank; Thibos, Larry; Bradley, Arthur

    2015-01-01

    We examined the effect of transverse chromatic aberration (TCA) on detection acuity for white-light interference fringes seen in Maxwellian view at various orientations and locations in the visual field. A circular patch (3.5° diameter, 3.2 log Trolands) of nominally high-contrast fringes was produced on the retina by a commercial instrument (the Lotmar Visometer, Haag Streit) mounted on a gimbal for controlled positioning of the stimulus in the visual field from 0° to 35° eccentricity. Detection acuity for white light fringes for all meridians and eccentricities ≥15° was maximum when fringes were oriented parallel to the visual meridian line. This meridional effect disappeared when a narrow-band filter was used to eliminate TCA. The meridional effect also disappeared when the interferometric stimulator was displaced laterally to align the instrument with the eye's local achromatic axis. Modelling confirmed that TCA is the major factor responsible for white-light meridional bias, with minor contribution arising from higher-order monochromatic aberrations and neural factors. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  17. Comparison on testability of visual acuity, stereo acuity and colour vision tests between children with learning disabilities and children without learning disabilities in government primary schools.

    Science.gov (United States)

    Abu Bakar, Nurul Farhana; Chen, Ai-Hong

    2014-02-01

    Children with learning disabilities might have difficulties to communicate effectively and give reliable responses as required in various visual function testing procedures. The purpose of this study was to compare the testability of visual acuity using the modified Early Treatment Diabetic Retinopathy Study (ETDRS) and Cambridge Crowding Cards, stereo acuity using Lang Stereo test II and Butterfly stereo tests and colour perception using Colour Vision Test Made Easy (CVTME) and Ishihara's Test for Colour Deficiency (Ishihara Test) between children in mainstream classes and children with learning disabilities in special education classes in government primary schools. A total of 100 primary school children (50 children from mainstream classes and 50 children from special education classes) matched in age were recruited in this cross-sectional comparative study. The testability was determined by the percentage of children who were able to give reliable respond as required by the respective tests. 'Unable to test' was defined as inappropriate response or uncooperative despite best efforts of the screener. The testability of the modified ETDRS, Butterfly stereo test and Ishihara test for respective visual function tests were found lower among children in special education classes ( P learning disabilities. Modifications of vision testing procedures are essential for children with learning disabilities.

  18. On random age and remaining lifetime for populations of items

    DEFF Research Database (Denmark)

    Finkelstein, M.; Vaupel, J.

    2015-01-01

    We consider items that are incepted into operation having already a random (initial) age and define the corresponding remaining lifetime. We show that these lifetimes are identically distributed when the age distribution is equal to the equilibrium distribution of the renewal theory. Then we...... develop the population studies approach to the problem and generalize the setting in terms of stationary and stable populations of items. We obtain new stochastic comparisons for the corresponding population ages and remaining lifetimes that can be useful in applications. Copyright (c) 2014 John Wiley...

  19. Analysis of laser photocoagulation with cataract surgery for improvement of visual acuity and macular edema in patients with cataract and diabetic macular edema

    Directory of Open Access Journals (Sweden)

    Chao-Yu Wang

    2016-02-01

    Full Text Available AIM:To explore laser photocoagulation with cataract surgery for improvement of visual acuity and macular edema in patients with cataract and diabetic macular edema.METHODS:A total of 60 patients(72 eyesfrom January 2014 to July 2015 in our hospital were selected, which all were diagnosed as cataract with diabetic macular edema. According to a random number table method, the patients were divided into observation group and control group, 30 cases(36 eyesin each group. The observation group was treated with combination therapy of laser photocoagulation before cataract surgeries, while the control group with the combination therapy of laser photocoagulation after cataract surgeries. At 2mo after surgeries, some routine examination, such as visual acuity, fundus examination after mydriasis, slit lamp examination, optical coherence tomography(OCTexamination, fluorescence angiography examination(FFAfor retinal blood vessels were applied in all the patients. RESULTS:The visual acuity of the observation group and the control group before treatments was not significantly different(P>0.05. At 2mo after treatments, the visual inspection showed that compared with the visual acuity before treatment, the visual acuity of the two groups were both significantly improved(PPP>0.05. At 2mo after treatments, compared with those before treatments, the macular thickness of two groups were both significantly improved(PPCONCLUSION:The laser photocoagulation before cataract surgery for patients with cataract and diabetic macular edema can significantly improve their visual acuity and macular thickness.

  20. Do stable non-ST-segment elevation acute coronary syndromes require admission to coronary care units?

    Science.gov (United States)

    van Diepen, Sean; Lin, Meng; Bakal, Jeffrey A; McAlister, Finlay A; Kaul, Padma; Katz, Jason N; Fordyce, Christopher B; Southern, Danielle A; Graham, Michelle M; Wilton, Stephen B; Newby, L Kristin; Granger, Christopher B; Ezekowitz, Justin A

    2016-05-01

    Clinical practice guidelines recommend admitting patients with stable non-ST-segment elevation acute coronary syndrome (NSTE ACS) to telemetry units, yet up to two-thirds of patients are admitted to higher-acuity critical care units (CCUs). The outcomes of patients with stable NSTE ACS initially admitted to a CCU vs a cardiology ward with telemetry have not been described. We used population-based data of 7,869 patients hospitalized with NSTE ACS admitted to hospitals in Alberta, Canada, between April 1, 2007, and March 31, 2013. We compared outcomes among patients initially admitted to a CCU (n=5,141) with those admitted to cardiology telemetry wards (n=2,728). Patients admitted to cardiology telemetry wards were older (median 69 vs 65years, PST-segment myocardial infarction or unstable angina. There were no differences in clinical outcomes observed between patients with NSTE ACS initially admitted to a ward or a CCU. These findings suggest that stable NSTE ACS may be managed appropriately on telemetry wards and presents an opportunity to reduce hospital costs and critical care capacity strain. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Applying cognitive acuity theory to the development and scoring of situational judgment tests.

    Science.gov (United States)

    Leeds, J Peter

    2017-11-09

    The theory of cognitive acuity (TCA) treats the response options within items as signals to be detected and uses psychophysical methods to estimate the respondents' sensitivity to these signals. Such a framework offers new methods to construct and score situational judgment tests (SJT). Leeds (2012) defined cognitive acuity as the capacity to discern correctness and distinguish between correctness differences among simultaneously presented situation-specific response options. In this study, SJT response options were paired in order to offer the respondent a two-option choice. The contrast in correctness valence between the two options determined the magnitude of signal emission, with larger signals portending a higher probability of detection. A logarithmic relation was found between correctness valence contrast (signal stimulus) and its detectability (sensation response). Respondent sensitivity to such signals was measured and found to be related to the criterion variables. The linkage between psychophysics and elemental psychometrics may offer new directions for measurement theory.

  2. Possible role for fundus autofluorescence as a predictive factor for visual acuity recovery after epiretinal membrane surgery.

    Science.gov (United States)

    Brito, Pedro N; Gomes, Nuno L; Vieira, Marco P; Faria, Pedro A; Fernandes, Augusto V; Rocha-Sousa, Amândio; Falcão-Reis, Fernando

    2014-02-01

    To study the potential association between fundus autofluorescence, spectral-domain optical coherence tomography, and visual acuity in patients undergoing surgery because of epiretinal membranes. Prospective, interventional case series including 26 patients submitted to vitrectomy because of symptomatic epiretinal membranes. Preoperative evaluation consisted of a complete ophthalmologic examination, autofluorescence, and spectral-domain optical coherence tomography. Studied variables included foveal autofluorescence (fov.AF), photoreceptor inner segment/outer segment (IS/OS) junction line integrity, external limiting membrane integrity, central foveal thickness, and foveal morphology. All examinations were repeated at the first, third, and sixth postoperative months. The main outcome measures were logarithm of minimal angle resolution visual acuity, fov.AF integrity, and IS/OS integrity. All cases showing a continuous IS/OS line had an intact fov.AF, whereas patients with IS/OS disruption could have either an increased area of foveal hypoautofluorescence or an intact fov.AF, with the latter being associated with IS/OS integrity recovery in follow-up spectral-domain optical coherence tomography imaging. The only preoperative variables presenting a significant correlation with final visual acuity were baseline visual acuity (P = 0.047) and fov.AF grade (P = 0.023). Recovery of IS/OS line integrity after surgery, in patients with preoperative IS/OS disruption and normal fov.AF, can be explained by the presence of a functional retinal pigment epithelium-photoreceptor complex, supporting normal photoreceptor activity. Autofluorescence imaging provides a functional component to the study of epiretinal membranes, complementing the structural information obtained with optical coherence tomography.

  3. Visual acuity in pelagic fishes and mollusks.

    Science.gov (United States)

    Gagnon, Yakir L; Sutton, Tracey T; Johnsen, Sönke

    2013-11-01

    In the sea, visual scenes change dramatically with depth. At shallow and moderate depths (cephalopods, and a gastropod using a custom-built apparatus. The hatchetfishes (Argyropelecus aculeatus and Sternoptyx diaphana) and the barrel-eye (Opisthoproctus soleatus) were found to have the best lenses, which may allow them to break the counterillumination camouflage of their prey. The heteropod lens had unidirectional aberrations that matched its ribbon-shaped retina. We also found that lens angular resolution increased with depth. Due to a similar trend in the angular separation between adjacent ganglion cells in the retinas of fishes, the perceived visual contrast at the retinal cutoff frequency was constant with depth. The increase in acuity with depth allows the predators to focus all the available light bioluminescent prey animals emit and detect their next meal. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. High-Acuity Information Is Retained through the Cortical Visual Hierarchy of Primates.

    Science.gov (United States)

    Chelazzi, Leonardo; Santandrea, Elisa

    2018-04-18

    Vision requires perception of both coarse layout and fine details of objects. In this issue of Neuron, Lu et al. (2018) describe a possible basis for the latter: neuronal clusters in area V4 coding high-acuity information, despite the tendency along the visual hierarchy to generate global representations of objects. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. The advanced glaucoma intervention study, 6: effect of cataract on visual field and visual acuity. The AGIS Investigators.

    Science.gov (United States)

    2000-12-01

    To investigate the effect of cataract on visual function and the role of cataract in explaining a race-treatment interaction in outcomes of glaucoma surgery. The Advanced Glaucoma Intervention Study (AGIS) enrolled 332 black patients (451 eyes) and 249 white patients (325 eyes) with advanced glaucoma. Eyes were randomly assigned to an argon laser trabeculoplasty (ALT)-trabeculectomy-trabeculectomy sequence or a trabeculectomy-ALT-trabeculectomy sequence. From the AGIS experience with cataract surgery during follow-up, we estimated the expected change in visual function scores from before cataract surgery to after cataract surgery. Then, for eyes with cataract not removed, we used these estimates of expected change to adjust visual function scores for the presumed effects of cataract. In turn, we used the adjusted scores to obtain cataract-adjusted main outcome measures. Average percent of eyes with decrease of visual field (APDVF) and average percent of eyes with decrease of visual acuity (APDVA). Within the 2 months before cataract surgery, visual acuity was better in eyes of white patients than of black patients by an average of approximately 2 lines on the visual acuity test chart. Cataract surgery improved visual acuity and visual field defect scores, with the amounts of improvement greater when preoperative visual acuity was lower. Adjustments for cataract brought about the following relative reductions: for APDVF, a relative reduction of 5% to 11% in black patients and 9% to 11% in white patients; for APDVA, a relative reduction of 45% to 49% in black patients and 31% to 38% in white patients; and for the APDVF and APDVA race-treatment interactions, relative reductions of 25% and 45%, respectively. On average, visual function scores improved after cataract surgery. The findings of reduced race-treatment interactions after adjustment for cataract do not alter our earlier conclusion that the AGIS 7-year results support use of the ALT

  6. Night-shift work and risk of compromised visual acuity among the workers in an electronics manufacturing company.

    Science.gov (United States)

    Lin, Yu-Cheng; Ho, Kuo-Jung

    2018-01-01

    To evaluate the association between night-shift work exposure and visual health, this cross-sectional study utilized visual acuity, a surrogate measure for visual function, as a parameter, and performed an analysis comparing visual acuity between daytime and nighttime employees in an electronics manufacturing company. Data of personal histories, occupational records, physical examinations and blood tests was obtained from the electronic health records of workers. The total of 8280 workers including 3098 women and 5182 men, wearing their own daily used eyeglasses, were included in the final analysis. The mean age of the sample population was 34.7 years old (standard deviation = 5.4 years). All workers were divided into 3 work categories - consistent daytime worker (CDW), day-shift worker (DSW) and night-shift worker (NSW). The check-up results of glasses-corrected visual acuity (c-VA) were utilized to classify individuals as good (≥ 1.2, both eyes) and inadequate (electronics manufacturing company. Int J Occup Med Environ Health 2018;31(1):71-79. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  7. Applications of stable isotope analysis in mammalian ecology.

    Science.gov (United States)

    Walter, W David; Kurle, Carolyn M; Hopkins, John B

    2014-01-01

    In this editorial, we provide a brief introduction and summarize the 10 research articles included in this Special Issue on Applications of stable isotope analysis in mammalian ecology. The first three articles report correction and discrimination factors that can be used to more accurately estimate the diets of extinct and extant mammals using stable isotope analysis. The remaining seven applied research articles use stable isotope analysis to address a variety of wildlife conservation and management questions from the oceans to the mountains.

  8. Atazanavir intracellular concentrations remain stable during pregnancy in HIV-infected patients.

    Science.gov (United States)

    Focà, Emanuele; Calcagno, Andrea; Bonito, Andrea; Simiele, Marco; Domenighini, Elisabetta; D'Avolio, Antonio; Quiros Roldan, Eugenia; Trentini, Laura; Casari, Salvatore; Di Perri, Giovanni; Castelli, Francesco; Bonora, Stefano

    2017-11-01

    Atazanavir (300 mg) boosted by ritonavir (100 mg) is the preferred third drug in pregnancy. However, there is still discordance on atazanavir dose increase during the third trimester. To evaluate plasma and intracellular atazanavir and ritonavir concentrations in HIV-infected women during pregnancy and after delivery. This was an observational study. HIV-infected pregnant patients treated with atazanavir/ritonavir plus either tenofovir/emtricitabine or abacavir/lamivudine had been prospectively enrolled after having signed a written informed consent form. Plasma and intracellular atazanavir and ritonavir Ctrough (24 ± 3 h after drug intake) were measured at each visit during the first, second and third trimesters and post-partum using validated HPLC-MS and HPLC-photodiode array methods (with direct evaluation of cellular volume). Data are described as median (IQR) and compared through non-parametric tests. Twenty-five patients were enrolled; at baseline, the median age was 32 years (27-35). All patients had plasma HIV RNA  0.05). This is the first demonstration that intracellular atazanavir exposure remains unchanged during pregnancy supporting the standard 300/100 mg atazanavir/ritonavir dosing throughout pregnancy. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Refraction and visual acuity in a national Danish cohort of 4-year-old children of extremely preterm delivery

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Bangsgaard, Regitze; Slidsborg, Carina

    2015-01-01

    PURPOSE: A recent threefold increase in laser treatment for advanced retinopathy of prematurity (ROP) triggered a nationwide preschool ophthalmic and developmental status among extremely preterm survivors. Here, we discuss refraction and visual acuity. METHODS: Survivors (n = 178) from a national...... was 0.1 in FT and 0.2 in PT, in Snellen equivalents 0.8 and 0.63. Snellen acuity ≤0.5 occurred across the ROP subgroups, but mainly in those with at least ROP stage 3. Two children had low vision. CONCLUSIONS: The overall fair outcome for refraction and function is in accordance with other recent...

  10. Taste acuity, plasma zinc levels, and weight loss during radiotherapy: a study of relationships

    International Nuclear Information System (INIS)

    Bolze, M.S.; Fosmire, G.J.; Stryker, J.A.; Chung, C.K.; Flipse, B.G.

    1982-01-01

    Thirty-five patients who were to undergo radiotherapy and 13 normal subjects were evaluated with taste questionnaires, taste acuity tests, and plasma zinc analyses. The studies were repeated on the patients in the fifth week of radiotherapy. The mean taste thresholds for NaCl (salt), sucrose (sweet), HCl (sour), and urea (bitter) were elevated and the plasma zinc levels were lower (77.2 +/- 11.8 vs. 94.6 +/- 30.1 g/100 ml, p . 0.055) for the patients than for the controls. However, there was not a significant correlation between the taste thresholds and plasma zinc levels at any time. The mean weight loss experienced by the 14 patients who reported subjective taste alteration in the fifth week was 3.1 kg versus 0.1 kg (p . 0.005) for those who did not report taste alteration. The data suggest that alterations in taste acuity, but not plasma zinc levels, are associated with weight loss during radiotherapy

  11. Taste acuity, plasma zinc levels, and weight loss during radiotherapy: a study of relationships

    International Nuclear Information System (INIS)

    Bolze, M.S.; Fosmire, G.J.; Stryker, J.A.; Chung, C.K.; Flipse, B.G.

    1982-01-01

    Thirty-five patients who were to undergo radiotherapy and 13 normal subjects were evaluated with taste questionnaires, taste acuity tests, and plasma zinc analyses. The studies were repeated on the patients in the fifth week of radiotherapy. The mean taste thresholds for NaCl (salt), sucrose (sweet), HCl (sour), and urea (bitter) were elevated and the plasma zinc levels were lower (77.2 +/- 11.8 vs. 94.6 +/- 30.1 g/100 ml, p = 0.055) for the patients than for the controls. However, there was not a significant correlation between the taste thresholds and plasma zinc levels at any time. The mean weight loss experienced by the 14 patients who reported subjective taste alteration in the fifth week was 3.1 kg versus 0.1 kg (p = 0.005) for those who did not report taste alteration. The data suggest that alterations in taste acuity, but not plasma zinc levels, are associated with weight loss during radiotherapy

  12. PROSPECTIVE EVALUATION OF VISUAL ACUITY AGREEMENT BETWEEN STANDARD EARLY TREATMENT DIABETIC RETINOPATHY STUDY CHART AND A HANDHELD EQUIVALENT IN EYES WITH RETINAL PATHOLOGY.

    Science.gov (United States)

    Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A

    2015-08-01

    To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.

  13. Nuclear fuel market: Supplies remaining stable and secured in the mean range

    International Nuclear Information System (INIS)

    Braatz, U.; Dibbert, H.J.

    1988-01-01

    Installation of additional power plant will keep the demand for uranium at a level allowing a constant uranium production during the next few years to come, although production will have to be kept lower than demand, as inventories have to be cut in order to achieve a favourable price structure. Prospects on a mean-term basis show that natural uranium supplies are ensured, at favourable purchaser prices. Concluded contracts for new nuclear power plant indicate a better plant capacity utilization in uranium production to be attainable by the 1990s. Conversion capacity, however, is expected to remain as excessive as presently for quite a long period still, although reprocessing produces increasing amounts of recovered uranium to be converted. The capacity for uranium separative work is favourable for the customers. Existing and projected production facilities already today ensure safe supplies beyond the turn of the millenium, under conditions by far better in terms of long-term competing energy sources. (orig./HP) [de

  14. Photovoltaic restoration of sight with high visual acuity

    Science.gov (United States)

    Lorach, Henri; Goetz, Georges; Smith, Richard; Lei, Xin; Mandel, Yossi; Kamins, Theodore; Mathieson, Keith; Huie, Philip; Harris, James; Sher, Alexander; Palanker, Daniel

    2015-01-01

    Patients with retinal degeneration lose sight due to gradual demise of photoreceptors. Electrical stimulation of the surviving retinal neurons provides an alternative route for delivery of visual information. We demonstrate that subretinal arrays with 70 μm photovoltaic pixels provide highly localized stimulation, with electrical and visual receptive fields of comparable sizes in rat retinal ganglion cells. Similarly to normal vision, retinal response to prosthetic stimulation exhibits flicker fusion at high frequencies, adaptation to static images and non-linear spatial summation. In rats with retinal degeneration, these photovoltaic arrays provide spatial resolution of 64 ± 11 μm, corresponding to half of the normal visual acuity in pigmented rats. Ease of implantation of these wireless and modular arrays, combined with their high resolution opens the door to functional restoration of sight. PMID:25915832

  15. Macular edema in Asian Indian premature infants with retinopathy of prematurity: Impact on visual acuity and refractive status after 1-year

    Directory of Open Access Journals (Sweden)

    Anand Vinekar

    2015-01-01

    Full Text Available Purpose: To report the impact of transient, self-resolving, untreated "macular edema" detected on spectral domain optical coherence tomography in Asian Indian premature infants with retinopathy of prematurity (ROP on visual acuity (VA and refraction at 1-year of corrected age. Materials and Methods: Visual acuity and refraction of 11 infants with bilateral macular edema (Group A was compared with gestational age-matched 16 infants with ROP without edema (Group B and 17 preterms infants without ROP and without edema (Group C at 3, 6, 9 and 12 months of corrected age using Teller Acuity Cards and cycloplegic retinoscopy. Sub-group analysis of the previously described pattern A and B macular edema was performed. Results: Visual acuity was lower in infants with macular edema compared with the other two control groups throughout the study period, but statistically significant only at 3 months. Visual improvement in these infants was highest between the 3 rd and 6 th month and plateaued by the end of the 1 st year with acuity comparable to the other two groups. The edema cohort was more hyperopic compared to the other two groups between 3 and 12 months of age. Pattern A edema had worse VA compared to pattern B, although not statistically significant. Conclusion: Macular edema, although transient, caused reduced VA as early as 3 months of corrected age in Asian Indian premature infants weighing <2000 g at birth. The higher hyperopia in these infants is possibly due to visual disturbances caused at a critical time of fovealization. We hypothesize a recovery and feedback mechanism based on the principles of active emmetropization to explain our findings.

  16. Examination of factors affecting gait properties in healthy older adults: focusing on knee extension strength, visual acuity, and knee joint pain.

    Science.gov (United States)

    Demura, Tomohiro; Demura, Shin-ichi; Uchiyama, Masanobu; Sugiura, Hiroki

    2014-01-01

    Gait properties change with age because of a decrease in lower limb strength and visual acuity or knee joint disorders. Gait changes commonly result from these combined factors. This study aimed to examine the effects of knee extension strength, visual acuity, and knee joint pain on gait properties of for 181 healthy female older adults (age: 76.1 (5.7) years). Walking speed, cadence, stance time, swing time, double support time, step length, step width, walking angle, and toe angle were selected as gait parameters. Knee extension strength was measured by isometric dynamometry; and decreased visual acuity and knee joint pain were evaluated by subjective judgment whether or not such factors created a hindrance during walking. Among older adults without vision problems and knee joint pain that affected walking, those with superior knee extension strength had significantly greater walking speed and step length than those with inferior knee extension strength (P pain in both knees showed slower walking speed and longer stance time and double support time. A decrease of knee extension strength and visual acuity and knee joint pain are factors affecting gait in the female older adults. Decreased knee extension strength and knee joint pain mainly affect respective distance and time parameters of the gait.

  17. Temporary marked impairment of visual acuity in a case of intraocular malignant lymphoma during radiation therapy

    International Nuclear Information System (INIS)

    Miyao, Yoko; Tada, Rei; Koizumi, Noriko; Yamada, Hideaki; Kinoshita, Shigeru; Ikeda, Tsunehiko

    2000-01-01

    A 56-year-old female was referred to us for blurring of both eyes since 2 years before. She had been diagnosed as chronic uveitis and responded poorly to systemic and topical corticosteroid. Her corrected visual acuity was 0.8 right and 0.5 left. Systemic studies, including magnetic resonance imaging and gadolinium scintigraphy, were negative. Vitreous biopsy led to the diagnosis of malignant lymphoma originating from the eye. Seven days after initiation of radiation at the daily doses of 2 Gy, massive subretinal infiltration developed in her right eye forming a niveau. Systemic prednisolone induced resolution of exudate with improved visual acuity to 1.0 13 days later. This cases illustrates that radiation may induce temporary aggravation of intraocular malignant lymphoma and that it may undergo resolution following systemic corticosteroid. (author)

  18. Using patient acuity data to manage patient care outcomes and patient care costs.

    Science.gov (United States)

    Van Slyck, A; Johnson, K R

    2001-01-01

    This article describes actual reported uses for patient acuity data that go beyond historical uses in determining staffing allocations. These expanded uses include managing patient care outcomes and health care costs. The article offers the patient care executive examples of how objective, valid, and reliable data are used to drive approaches to effectively influence decision making in an increasingly competitive health care environment.

  19. Revealing Detail along the Visual Hierarchy: Neural Clustering Preserves Acuity from V1 to V4.

    Science.gov (United States)

    Lu, Yiliang; Yin, Jiapeng; Chen, Zheyuan; Gong, Hongliang; Liu, Ye; Qian, Liling; Li, Xiaohong; Liu, Rui; Andolina, Ian Max; Wang, Wei

    2018-04-18

    How primates perceive objects along with their detailed features remains a mystery. This ability to make fine visual discriminations depends upon a high-acuity analysis of spatial frequency (SF) along the visual hierarchy from V1 to inferotemporal cortex. By studying the transformation of SF across macaque parafoveal V1, V2, and V4, we discovered SF-selective functional domains in V4 encoding higher SFs up to 12 cycles/°. These intermittent higher-SF-selective domains, surrounded by domains encoding lower SFs, violate the inverse relationship between SF preference and retinal eccentricity. The neural activities of higher- and lower-SF domains correspond to local and global features, respectively, of the same stimuli. Neural response latencies in high-SF domains are around 10 ms later than in low-SF domains, consistent with the coarse-to-fine nature of perception. Thus, our finding of preserved resolution from V1 into V4, separated both spatially and temporally, may serve as a connecting link for detailed object representation. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. LONG-TERM RETROSPECTIVE ANALYSIS OF VISUAL ACUITY AND OPTICAL COHERENCE TOPOGRAPHIC CHANGES AFTER SINGLE VERSUS DOUBLE PEELING DURING VITRECTOMY FOR MACULAR EPIRETINAL MEMBRANES.

    Science.gov (United States)

    Jung, Jesse J; Hoang, Quan V; Ridley-Lane, Megan L; Sebrow, Dov B; Dhrami-Gavazi, Elona; Chang, Stanley

    2016-11-01

    To determine the long-term effect of internal limiting membrane with associated epiretinal membrane (ERM) peeling versus single peeling alone in terms of best-corrected visual acuity and anatomical outcomes on spectral-domain optical coherence tomography. This retrospective comparative cohort study of patients who had follow-up of >1 year and underwent surgery for ERM by a single surgeon (S.C.) from January 1, 2008 to December 31, 2012 compared cases in which the internal limiting membrane was stained with brilliant blue G to facilitate double peeling (n = 42) and single peeling (n = 43) of the ERM alone for up to 3 years of follow-up. For continuous variables, an independent two-tailed t-test was performed. For binary variables, the Fisher's exact test was performed. Statistical significance was defined as P peeling group were more likely to have ERM remaining in the central fovea postoperatively (P = 0.0020, becoming significant by postoperative Year 1, P = 0.022) and less likely to develop inner retinal dimpling (P = 0.000, becoming significant by postoperative Month 3, P = 0.015). At 3 years, central foveal thickness had decreased in the single-peeling group by -136.9 µm and by -84.1 μm in the double-peeling group, which was not significantly different (P = 0.08). Mean best-corrected visual acuity improved in both the groups at all time points. There was no statistically significant difference between the 2 groups at 3 years (P = 0.44; single-peeling group, 0.32 ± 0.42, Snellen 20/42; double-peeling group, 0.23 ± 0.27, Snellen 20/34). Brilliant blue G-assisted internal limiting membrane peeling for ERM results in a more thorough removal of residual ERM around the paracentral fovea. However, there is no difference in long-term best-corrected visual acuity at 3 years and a greater likelihood of inner retinal dimpling.

  1. The two sides of sensory-cognitive interactions: effects of age, hearing acuity, and working memory span on sentence comprehension

    Directory of Open Access Journals (Sweden)

    Renee eDeCaro

    2016-02-01

    Full Text Available Reduced hearing acuity is among the most prevalent of chronic medical conditions among older adults. An experiment is reported in which comprehension of spoken sentences was tested for older adults with good hearing acuity or with a mild-to-moderate hearing loss, and young adults with age-normal hearing. Comprehension was measured by participants’ ability to determine of the agent of an action in sentences that expressed this relation with a syntactically less complex subject-relative construction or a syntactically more complex object-relative construction. Agency determination was further challenged by inserting a prepositional phrase into sentences between the person performing an action and the action being performed. As a control, prepositional phrases of equivalent length were also inserted into sentences in a non-disruptive position. Effects on sentence comprehension of age, hearing acuity, prepositional phrase placement and sound level of stimulus presentations appeared only for comprehension of sentences with the more syntactically complex object-relative structures. Working memory as tested by reading span scores accounted for a significant amount of the variance in comprehension accuracy. Once working memory capacity and hearing acuity were taken into account, chronological age among the older adults contributed no further variance to comprehension accuracy. Results are discussed in terms of the positive and negative effects of sensory-cognitive interactions in comprehension of spoken sentences and lend support to a framework in which domain-general executive resources, notably verbal working memory, play a role in both linguistic and perceptual processing.

  2. Predictive Factors in OCT Analysis for Visual Outcome in Exudative AMD

    Directory of Open Access Journals (Sweden)

    Maria-Andreea Gamulescu

    2012-01-01

    Full Text Available Background. Reliable predictive factors for therapy outcome may enable treating physicians to counsel their patients more efficiently concerning probability of improvement or time point of discontinuation of a certain therapy. Methods. This is a retrospective analysis of 87 patients with exudative age-related macular degeneration who received three monthly intravitreal ranibizumab injections. Visual acuity before initiation of intravitreal therapy and 4–6 weeks after last intravitreal injection was compared and related to the preoperative visualisation of continuity of the outer retinal layers as assessed by OCT: external limiting membrane (ELM, inner photoreceptor segments (IPS, junction between inner and outer segments (IS/OS, and outer photoreceptor segments (OPS. Results. Visual acuity increased in 40 of 87 (46.0% patients, it remained stable in 25 (28.7%, and 22 (25.3% patients had decreased visual acuity four to six weeks after triple intravitreal ranibizumab injections. No statistically significant predictive value could be demonstrated for grade of continuity of outer retinal layers concerning visual acuity development. Conclusions. In our series of AMD patients, grade of continuity of outer retinal layers was not a significant predictive value for visual acuity development after triple ranibizumab injections.

  3. Lawn mower injuries as a cause of serious visual acuity impairment – Case reports

    Directory of Open Access Journals (Sweden)

    Monika Jasielska

    2017-05-01

    Lawn mower induced eye injuries are a significant cause of serious visual acuity impairment or blindness. The presented study shows that lawn mower eye injuries are still a therapeutic, social and economic problem, yet are very preventable with proper eye protection and patients’ education. Current prevention strategies are inadequate, and therefore should be updated.

  4. Assessing physician leadership styles: application of the situational leadership model to transitions in patient acuity.

    Science.gov (United States)

    Skog, Alexander; Peyre, Sarah E; Pozner, Charles N; Thorndike, Mary; Hicks, Gloria; Dellaripa, Paul F

    2012-01-01

    The situational leadership model suggests that an effective leader adapts leadership style depending on the followers' level of competency. We assessed the applicability and reliability of the situational leadership model when observing residents in simulated hospital floor-based scenarios. Resident teams engaged in clinical simulated scenarios. Video recordings were divided into clips based on Emergency Severity Index v4 acuity scores. Situational leadership styles were identified in clips by two physicians. Interrater reliability was determined through descriptive statistical data analysis. There were 114 participants recorded in 20 sessions, and 109 clips were reviewed and scored. There was a high level of interrater reliability (weighted kappa r = .81) supporting situational leadership model's applicability to medical teams. A suggestive correlation was found between frequency of changes in leadership style and the ability to effectively lead a medical team. The situational leadership model represents a unique tool to assess medical leadership performance in the context of acuity changes.

  5. Charles River altered Schaedler flora (CRASF) remained stable for four years in a mouse colony housed in individually ventilated cages.

    Science.gov (United States)

    Stehr, Matthias; Greweling, Marina C; Tischer, Sabine; Singh, Mahavir; Blöcker, Helmut; Monner, David A; Müller, Werner

    2009-10-01

    As recommendations for specific pathogen-free housing change, mouse facilities need to re-derive their colonies repeatedly in order to eliminate specified bacteria or viruses. This paper describes the establishment of a new mouse facility using as starting point a small colony of CD-1 mice colonized with the Charles River altered Schaedler flora (CRASF) housed in individually ventilated cages (IVCs). The import of new strains was performed exclusively via embryo transfer using CD-1 mice as recipients. The integrity of the CRASF in caecum samples of the original CD-1 colony and of three inbred mouse lines imported into the colony was proven by a quantitative realtime polymerase chain reaction approach. Furthermore, we searched for bacterial contaminants in the gut flora using non-specific 16S rRNA primers. The bacterial sequences found were closely related to but not exclusively sequences of altered Schaedler flora (ASF) members, suggesting that the ASF is heterogeneous rather than restricted to the eight defined bacteria. Moreover, no pathogens were found, neither using the non-specific 16S rRNA primers nor in routine quarterly health monitoring. As one effect of this defined gut flora, interleukin-10 knockout mice are devoid of colitis in our facility. In conclusion, our approach building up a mouse facility using foster mothers and embryo transfer as well as a strict barrier system and IVCs is suitable to maintain a colony free from contaminating bacteria over the long term. CRASF remained stable for seven mouse generations and was efficiently transferred to the imported mouse strains.

  6. A contralateral eye study comparing apodized diffrative and full diffrative lenses: wavefront analysis and distance and near uncorrected visual acuity

    Directory of Open Access Journals (Sweden)

    Marcony Rodrigues de Santhiago

    2009-01-01

    Full Text Available PURPOSE: To evaluate intraindividual visual acuity, wavefront errors and modulation transfer functions in patients implanted with two diffractive multifocal intraocular lenses. METHODS: This prospective study examined 40 eyes of 20 cataract patients who underwent phacoemulsification and implantation of a spherical multifocal ReSTOR intraocular lens in one eye and an aspheric Tecnis ZM900 multifocal intraocular lens in the other eye. The main outcome measures, over a 3-month follow-up period, were the uncorrected photopic distance and near visual acuity and the defocus curve. The visual acuity was converted to logMAR for statistical analysis and is presented in decimal scale. The wavefront error and modulation transfer function were also evaluated in both groups. RESULTS: At the 3-month postoperative visit, the mean photopic distance uncorrected visual acuity (UCVA was 0.74 ± 0.20 in the ReSTOR group and 0.76 ± 0.22 in the Tecnis group (p=0.286. The mean near UCVA was 0.96 ± 0.10 in the ReSTOR group and 0.93 ± 0.14 in the Tecnis group (p=0.963. The binocular defocus curve showed measurements between the peaks better than 0.2 logMAR. The total aberration, higher-order aberration and coma aberration were not significantly different between the groups. The spherical aberration was significantly lower in the Tecnis group than in the ReSTOR group. (p=0.004. Both groups performed similarly for the modulation transfer function. CONCLUSION: The ReSTOR SN60D3 and Tecnis ZM 900 intraocular lenses provided similar photopic visual acuity at distance and near. The diffractive intraocular lenses studied provided a low value of coma and spherical aberrations, with the Tecnis intraocular lens having a statistically lower spherical aberration compared to the ReSTOR intraocular lens. In the 5 mm pupil diameter analyses, both intraocular lens groups showed similar modulation transfer functions.

  7. Effect of magnetic resonance imaging on near visual acuity Efecto de la resonancia magnética sobre la agudeza visual cercana

    OpenAIRE

    José David Paulo Trujillo; Juan Carlos Vergara; Jorge Hernando Donado Gómez; Luz Marina Agudelo; Mercedes Cecilia Molina Betancur; Andrés Ignacio Arbeláez Medina; Carlos Andrés Molina Betancur

    2007-01-01

    Purpose: To determine the variation of near visual acuity, in patients exposed during short periods to intense magnetic fields in studies of magnetic resonance imaging. Methods: Descriptive study of a case series that included 40 healthy and literate individuals older than 40 years, nine of them men, submitted to a procedure of head and neck magnetic resonance imaging; all of them had near visual acuity better than 20/200 without glasses, and were not under the effects of ansiolytic medicatio...

  8. Experimental validation of a Bayesian model of visual acuity.

    LENUS (Irish Health Repository)

    Dalimier, Eugénie

    2009-01-01

    Based on standard procedures used in optometry clinics, we compare measurements of visual acuity for 10 subjects (11 eyes tested) in the presence of natural ocular aberrations and different degrees of induced defocus, with the predictions given by a Bayesian model customized with aberrometric data of the eye. The absolute predictions of the model, without any adjustment, show good agreement with the experimental data, in terms of correlation and absolute error. The efficiency of the model is discussed in comparison with image quality metrics and other customized visual process models. An analysis of the importance and customization of each stage of the model is also given; it stresses the potential high predictive power from precise modeling of ocular and neural transfer functions.

  9. Clinical outcomes of a new diffractive multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Baha Toygar

    2017-12-01

    Full Text Available AIM: To evaluate clinical outcomes after implantation of a new diffractive aspheric multifocal intraocular lens (IOL with +3.00 addition power. METHODS: This is a retrospective, consecutive case series of cataract patients who underwent bilateral implantation of the Optiflex MO/HF D012 (Moss Vision Inc. Ltd, London, UK multifocal IOL. Patients followed for 6mo were included in the study. Data on distance, intermediate and near visual acuity, refractive error [manifest spherical equivalent (MSE], contrast sensitivity, adverse events, subjective symptoms, spectacle independence and patient satisfaction [visual function questionnaire (VFQ-25 questionnaire] were retrieved from electronic medical records and analyzed. RESULTS: Forty eyes of 20 patients with a mean age of 66.7±8.5y (range: 53-82 were included in the study. Mean uncorrected distance, near and intermediate visual acuity remained stable through postoperative visits and was 0.19±0.19 logMAR, Jaeger 4 and Jaeger 3 respectively at the 6mo visit. At the end of postoperative 6mo, MSE was -0.14±0.42 diopters (D and 98% of the eyes were within 1.00 D of target refraction. Postoperative low contrast (10% visual acuity remained stable (P=0.54 through follow up visits with a mean of 0.35±0.17 logMAR at the 6mo visit. There were no reported adverse events. None of the patients reported subjective symptoms of halo or glare. Spectacle independence rate was 90%. Mean VFQ-25 questionnaire score was 93.5±6.12. CONCLUSION: The Optiflex MO/HF-DO12 IOL was safely implanted and successfully restored distance, intermediate and near visual acuity without impairing contrast sensitivity. High levels of spectacle independence were achieved at all distances including intermediate distance.

  10. Using On-scene EMS Responders' Assessment and Electronic Patient Care Records to Evaluate the Suitability of EMD-triaged, Low-acuity Calls for Secondary Nurse Triage in 911 Centers.

    Science.gov (United States)

    Scott, Greg; Clawson, Jeff; Fivaz, Mark C; McQueen, Jennie; Gardett, Marie I; Schultz, Bryon; Youngquist, Scott; Olola, Christopher H O

    2016-02-01

    Using the Medical Priority Dispatch System (MPDS) - a systematic 911 triage process - to identify a large subset of low-acuity patients for secondary nurse triage in the 911 center is a largely unstudied practice in North America. This study examines the ALPHA-level subset of low-acuity patients in the MPDS to determine the suitability of these patients for secondary triage by evaluating vital signs and necessity of lights-and-siren transport, as determined by attending Emergency Medical Services (EMS) ambulance crews. The primary objective of this study was to determine the clinical status of MPDS ALPHA-level (low-acuity) patients, as determined by on-scene EMS crews' patient care records, in two US agencies. A secondary objective was to determine which ALPHA-level codes are suitable candidates for secondary triage by a trained Emergency Communication Nurse (ECN). In this retrospective study, one full year (2013) of both dispatch data and EMS patient records data, associated with all calls coded at the ALPHA-level (low-acuity) in the dispatch protocol, were collected. The primary outcome measure was the number and percentage of ALPHA-level codes categorized as low-acuity, moderate-acuity, high-acuity, and critical using four common vital signs to assign these categories: systolic blood pressure (SBP), pulse rate (PR), oxygen saturation (SpO2), and Glasgow Coma Score (GCS). Vital sign data were obtained from ambulance crew electronic patient care records (ePCRs). The secondary endpoint was the number and percentage of ALPHA-level codes that received a "hot" (lights-and-siren) transport. Out of 19,300 cases, 16,763 (86.9%) were included in the final analysis, after excluding cases from health care providers and those with missing data. Of those, 89% of all cases did not have even one vital sign indicator of unstable patient status (high or critical vital sign). Of all cases, only 1.1% were transported lights-and-siren. With the exception of the low-acuity, ALPHA

  11. Spontaneous Rotation of a Toric Implantable Collamer Lens

    Directory of Open Access Journals (Sweden)

    Alejandro Navas

    2010-11-01

    Full Text Available We present a case of toric implantable collamer lens (TICL spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA was 20/800 and 20/1200, respectively, with –7.75 –4.25 × 0° and –8.25 –5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 –4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months’ follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation.

  12. Eccentric Macular Hole after Pars Plana Vitrectomy for Epiretinal Membrane Without Internal Limiting Membrane Peeling: A Case Report.

    Science.gov (United States)

    Garnavou-Xirou, Christina; Xirou, Tina; Kabanarou, Stamatina; Gkizis, Ilias; Velissaris, Stavros; Chatziralli, Irini

    2017-12-01

    Postoperative eccentric macular hole formation is an uncommon complication after pars plana vitrectomy (PPV) without internal limiting membrane (ILM) peeling for the treatment of epiretinal membrane (ERM). We present a case of eccentric macular hole formation after PPV for ERM without ILM peeling. A 68-year-old male patient presented with ERM and visual acuity of 6/24 in his left eye. He underwent 23-gauge PPV without ILM peeling for treatment of ERM. One week postoperatively the retina was attached and the epiretinal membrane was successfully removed, while visual acuity was 6/9. One month after PPV, a single eccentric retinal hole below the macula was detected using fundoscopy and subsequently confirmed by optical coherence tomography. At this time the visual acuity was 6/9 and the patient reported no symptoms. No further intervention was attempted and at the 9-month follow-up, the visual acuity and the size of the eccentric macular hole remained stable. Eccentric macular holes can be developed after PPV even without ILM peeling and are usually managed conservatively by observation.

  13. Unexpected Genetic Cause in Two Female Siblings with High Myopia and Reduced Visual Acuity

    Directory of Open Access Journals (Sweden)

    M. N. Preising

    2018-01-01

    Full Text Available In daily life, myopia is a frequent cause of reduced visual acuity (VA due to missing or incomplete optical correction. While the genetic cause of high myopia itself is not well understood, a significant number of cases are secondary to hereditary malfunctions or degenerations of the retina. The mechanism by which this occurs remains yet unclear. Two female siblings, 4 y and 2 y, respectively, from a consanguineous Pakistani family were referred to our department for reduced VA and strabismus. Both girls were highly myopic and hence were further examined using standard clinical tests and electroretinography (ERG. The latter confirmed confounded electrical coupling of photoreceptors and bipolar cells. Further inquiry and testing confirmed a similar condition for the father including impaired night vision, reduced VA, photophobia, and an equally characteristic ERG. Findings in the mother were unremarkable. Subsequent genetic analysis of autosomal recessive and X-linked genes for congenital stationary night blindness (CSNB revealed a novel homozygous splice site mutation in CACNA1F in the two girls transmitted from both the father and the mother. While in males the above clinical constellation is a frequent finding, this report, to the authors’ knowledge, is the first demonstrating biallelic mutations at the CACNA1F locus in females.

  14. Post-treatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanoma: Dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Gillin, Michael; Albano, Katherine; Erickson, Beth

    1996-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1993, 63 patients underwent 125 I episcleral plaque application for the treatment of choroidal melanoma. Mean tumor height was 4.6 mm (range 1.7-8.3 mm). Plaques utilized were of COMS design. Doses and dose rates at the tumor apex, macula, and optic disc were obtained. Visual acuity data prior to and after plaque application was available for 52 patients. 9 patients were excluded from analysis secondary to co-morbidities or disease progression. 43 records were scored to assess if a decrease in visual acuity of ≥ 2 lines on a standard Snellen eye chart had occurred. Statistical analysis was performed using chi-square tests of significance. Results: Of the 63 total patients, 59 (93.7%) were alive at a median follow-up of 36 months. Local progression occurred in (7(63)) (11.1%). Median dose and dose rate to the tumor apex were 90 Gy and 97.2 cGy/hr, respectively. Of the 43 patients with post-treatment visual acuity analysis, 28 (65.1%) experienced visual loss of ≥ 2 lines on a standard eye chart. Median time to altered visual acuity was 20 months. Median dose and dose rates to the macula in patients with a significant visual loss were 123.3 Gy and 122.5 cGy/hr, respectively, compared with 38 Gy and 51.9 cGy/hr in those without notable visual change. These differences reached statistical significance at a dose and dose rate to the macula of 82.0 Gy (p 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of decreased visual acuity. Both total dose and dose rates to the macula and optic disc correlated strongly with post-treatment visual outcome. This information may be valuable in decisions about the dose and dose rates used to treat

  15. Post-treatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanoma: dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Murray, Kevin; Gillin, Michael; Albano, Katherine; Erickson, Beth

    1996-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1994, 63 patients underwent 125 I episcleral plaque application for the treatment of choroidal melanoma. Mean tumor height was 4.6 mm (range 1.7-8.3 mm). Plaques utilized were of COMS design. Doses and dose rates at the tumor apex, macula, and optic disc were obtained. Visual acuity data prior to and after plaque application was available for 52 patients. Nine patients were excluded from analysis secondary to co-morbidities or disease progression. Forty-three records were scored to assess if a decrease in visual acuity of ≥ 2 lines on a standard Snellen eye chart had occurred. Statistical analysis was performed using chi-square tests of significance. Results: Of the 63 total patients, 59 (93.7%) were alive at a median follow-up of 36 months. Local progression occurred in 7/63 (11.1%). Median dose and dose rate to the tumor apex were 90 Gy and 97.2 cGy/hr, respectively. Of the 43 patients with post-treatment visual acuity analysis, 28 (65.1%) experienced visual loss of ≥ 2 lines on a standard eye chart. Median time to altered visual acuity was 20 months. Median dose and dose rates to the macula in patients with a significant visual loss were 123.3 Gy and 122.5 cGy/hr, respectively, compared with 38 Gy and 51.9 cGy/hr in those without notable visual change. These differences reached statistical significance at a dose and dose rate to the macula of 82.0 Gy (p 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of decreased visual acuity. Both total dose and dose rates to the macula and optic disc correlated strongly with post-treatment visual outcome. This information may be valuable in decisions about the dose and dose rates used to

  16. CLINICAL PRESENTATION OF LENS INDUCED GLAUCOMA: STUDY OF EPIDEMIOLOGY, DURATION OF SYMPTOMS, INTRAOCULAR PRESSURE AND VISUAL ACUITY

    Directory of Open Access Journals (Sweden)

    Venkataratnam

    2015-10-01

    Full Text Available BACKGROUND: Lens Induced Glaucoma is a common cause of ocular morbidity. OBJECTIVES: Our study was to know the Epidemiological factors, Duration of Symptoms, Visual Acuity and Intraocular Pressure in the clinical Presentation of Lens Induced Glaucoma. MATERIALS AND METHODS : This w as a tertiary hospital based prospective study in the department of Glaucoma, Sarojini Devi Eye Hospital and Regional Institute of Ophthalmology (RIO, Osmania Medical College, Hyderabad over a period from March 2015 to August 2015. 50 Patients clinically diagnosed as Lens Induced Glaucoma (LIG were studied with the data of Age, Sex, literacy, Laterality and Rural / Urban status with the duration of symptoms, Intraocular pressure and Visual Acuity. The data was analyzed by simple statistical methods. RESULT S: 50 patients, clinically diagnosed as Lens Induced Glaucoma (LIG were studied. Age group distribution was 1(2.0% in 40 - 50yrs, 13 ( 26.0% in >50 - 60yrs, 26(52.0% in >60 - 70yrs and 10(20.0% in > 70 yrs. Sex distribution was 23(46.0% of Males and 27(54.0% of Females. Urban / Rural status was 15(30.0% of Urban and 35(70.0% of Rural. Literacy status was 7(14.0% of Literate and 43(86.0% of Illiterate. Laterality was RE in 24(48.0% and LE in 26(52.0%. Duration of the presenting symptoms before re porting to the Hospital was 12.0% in 2wks. Intraocular pressure (IOP in mm of Hg showed no case (0.0% in 20 – 40, 27(54.0% in >40 - 60 and 5(10.0% >60 wit h the Mean IOP of 42.12 mm of Hg. Visual Acuity (VA was PL +ve in 24(48.0 and HM - 3/60. CONCLUSIONS: Increasing age, female gender, rural, illiterate, and delayed reporting to the hospital after the pre senting symptoms were the common risk factors with increased Intraocular pressure and poor visual acuity in the clinical presentation of Lens induced Glaucoma.

  17. Comparison of visual acuity in reduced lumination and facility of ocular accommodation in table tennis champions and non- players.

    Science.gov (United States)

    Jafarzadehpur, Ebrahim; Yarigholi, Mohammad R

    2004-03-01

    A table tennis player should fixate at different distances; track the objects with different speed, and in different visual environment. Their visual skills must be well developed for these capabilities. Therefore, visual acuity in reduced lumination and facility of ocular accommodation those are two criteria for visual skills have been compared in table tennis players and normal non-players. Twenty-nine young table tennis champions and 29 normal matched non-players (did not take part in any racket sports game) were evaluated. Basic visual and eye examinations were done for both of them. Normal results in basic examination were fundamental requirement for all the subjects. +/-2.00 sphere lenses for accommodation facility are used. An electrical current regulator changed the output light intensity of a conventional chart projector (Topcon). Light intensity decreased to 10 cd·m(-2) and visual acuity tested. In comparison of visual acuity in reduced lumination and facility of ocular accommodation in table tennis champions and non-players there are significant differences (p reflecting a better perceptual system of experts to the constraints encountered during table tennis and its use in practical settings for evaluating athletes or detecting sport talents. However some visual and perceptual training that usually used in orthoptics can be used for novice table tennis player to improve their abilities. Key PointsThat the ability of a champion depends on many sensory, motor and perceptual factors.Visual factors such as facility of accommodation and visual acuity in reduced lumination should be considered in table tennis players.Visual training may be useful for novice and also for experts.

  18. A study of static, kinetic, and dynamic visual acuity in 102 Japanese professional baseball players

    Directory of Open Access Journals (Sweden)

    Hoshina K

    2013-03-01

    Full Text Available Kohji Hoshina,1 Yuichi Tagami,2 Osamu Mimura,3 Hiroshi Edagawa,4 Masao Matsubara,5 Teiichi Nakayama6 1Hoshina Eye Clinic, Nishinomiya, Japan; 2Department of Ophthalmology, Kobe Century Memorial Hospital, Kobe, Japan; 3Department of Ophthalmology, Hyogo College of Medicine, Nishinomiya, Japan; 4Edagawa Eye Clinic, Tokyo, Japan; 5Department of Ophthalmology, Tokyo Women's Medical University Medical Center East, Tokyo, Japan; 6Ritsumeikan University, Kyoto, Japan Background: It seemed that visual functions might have some effects on the performance of baseball players. We measured static, kinetic, and dynamic visual acuity (SVA, KVA, and DVA, respectively of Japanese professional baseball players to ascertain whether there would be any difference in SVA, KVA, and DVA among player groups stratified according to their performance level. Methods: The subjects were 102 male professional baseball players with a mean age of 26 years who were members of a Japanese professional baseball club from 2000 to 2009. They were stratified into three groups according to their performance level: A (players who were on the roster of the top-level team all the time throughout the study period, B (players who were on the roster of the top-level team sometimes but not all the time, and C (players who were never on the roster of the top-level team. They were interviewed for the use of corrective visual aids, and examined for SVA, KVA, and DVA. The measurements of these parameters were compared among groups A, B, and C. We also investigated and analyzed the association of KVA or DVA with player position (pitchers or fielders and with hand dominance for batting. KVA was compared between the pitchers and the fielders because they each require different playing skills. DVA was compared between the right-handed and the left-handed batters. Results: There was no statistically significant difference among groups A, B, and C. There was a statistically significant difference in

  19. Lrit1, a Retinal Transmembrane Protein, Regulates Selective Synapse Formation in Cone Photoreceptor Cells and Visual Acuity.

    Science.gov (United States)

    Ueno, Akiko; Omori, Yoshihiro; Sugita, Yuko; Watanabe, Satoshi; Chaya, Taro; Kozuka, Takashi; Kon, Tetsuo; Yoshida, Satoyo; Matsushita, Kenji; Kuwahara, Ryusuke; Kajimura, Naoko; Okada, Yasushi; Furukawa, Takahisa

    2018-03-27

    In the vertebrate retina, cone photoreceptors play crucial roles in photopic vision by transmitting light-evoked signals to ON- and/or OFF-bipolar cells. However, the mechanisms underlying selective synapse formation in the cone photoreceptor pathway remain poorly understood. Here, we found that Lrit1, a leucine-rich transmembrane protein, localizes to the photoreceptor synaptic terminal and regulates the synaptic connection between cone photoreceptors and cone ON-bipolar cells. Lrit1-deficient retinas exhibit an aberrant morphology of cone photoreceptor pedicles, as well as an impairment of signal transmission from cone photoreceptors to cone ON-bipolar cells. Furthermore, we demonstrated that Lrit1 interacts with Frmpd2, a photoreceptor scaffold protein, and with mGluR6, an ON-bipolar cell-specific glutamate receptor. Additionally, Lrit1-null mice showed visual acuity impairments in their optokinetic responses. These results suggest that the Frmpd2-Lrit1-mGluR6 axis regulates selective synapse formation in cone photoreceptors and is essential for normal visual function. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.

  20. Wound center facility billing: A retrospective analysis of time, wound size, and acuity scoring for determining facility level of service.

    Science.gov (United States)

    Fife, Caroline E; Walker, David; Farrow, Wade; Otto, Gordon

    2007-01-01

    Outpatient wound center facility reimbursement for Medicare beneficiaries can be a challenge to determine and obtain. To compare methods of calculating facility service levels for outpatient wound centers and to demonstrate the advantages of an acuity-based billing system (one that incorporates components of facility work that is non-reimbursable by procedure codes and that represents an activity-based costing approach to medical billing), a retrospective study of 5,098 patient encounters contained in a wound care-specific electronic medical record database was conducted. Approximately 500 patient visits to the outpatient wound center of a Texas regional hospital between April 2003 and November 2004 were categorized by service level in documentation and facility management software. Visits previously billed using a time-based system were compared to the Centers for Medicare and Medicaid Services' proposed three-tiered wound size-based system. The time-based system also was compared to an acuity-based scoring system. The Pearson correlation coefficient between billed level of service by time and estimated level of service by acuity was 0.442 and the majority of follow-up visits were billed as Level 3 and above (on a time level of 1 to 5) , confirming that time is not a surrogate for actual work performed. Wound size also was found to be unrelated to service level (Pearson correlation = 0.017) and 97% of wound areas were billings than extremes; no other method produced this distribution. Hospital-based outpatient wound centers should develop, review, and refine acuity score-based models on which to determine billed level of service.

  1. Cultivating Perspectival Acuity: The Value and Cost of Integrating Theory, Craft, Research, and Practice

    Directory of Open Access Journals (Sweden)

    Joe Manganelli

    2016-10-01

    Full Text Available This paper presents reflections on integrating theory, craft, research, and practice to improve the accuracy and resiliency of each. The reflections build toward a set of statements about the value and the cost of integrating theory, craft, research, and practice. Specifically, the authors offer the Privileged Work / Non-Privileged Work Framework and concept of cultivating Perspectival Acuity.

  2. Artificial Intelligence Can Predict Daily Trauma Volume and Average Acuity.

    Science.gov (United States)

    Stonko, David P; Dennis, Bradley M; Betzold, Richard D; Peetz, Allan B; Gunter, Oliver L; Guillamondegui, Oscar D

    2018-04-19

    The goal of this study was to integrate temporal and weather data in order to create an artificial neural network (ANN) to predict trauma volume, the number of emergent operative cases, and average daily acuity at a level 1 trauma center. Trauma admission data from TRACS and weather data from the National Oceanic and Atmospheric Administration (NOAA) was collected for all adult trauma patients from July 2013-June 2016. The ANN was constructed using temporal (time, day of week), and weather factors (daily high, active precipitation) to predict four points of daily trauma activity: number of traumas, number of penetrating traumas, average ISS, and number of immediate OR cases per day. We trained a two-layer feed-forward network with 10 sigmoid hidden neurons via the Levenberg-Marquardt backpropagation algorithm, and performed k-fold cross validation and accuracy calculations on 100 randomly generated partitions. 10,612 patients over 1,096 days were identified. The ANN accurately predicted the daily trauma distribution in terms of number of traumas, number of penetrating traumas, number of OR cases, and average daily ISS (combined training correlation coefficient r = 0.9018+/-0.002; validation r = 0.8899+/- 0.005; testing r = 0.8940+/-0.006). We were able to successfully predict trauma and emergent operative volume, and acuity using an ANN by integrating local weather and trauma admission data from a level 1 center. As an example, for June 30, 2016, it predicted 9.93 traumas (actual: 10), and a mean ISS score of 15.99 (actual: 13.12); see figure 3. This may prove useful for predicting trauma needs across the system and hospital administration when allocating limited resources. Level III STUDY TYPE: Prognostic/Epidemiological.

  3. The (lack of) relation between straylight and visual acuity. Two domains of the point-spread-function

    NARCIS (Netherlands)

    van den Berg, Thomas J T P

    2017-01-01

    PURPOSE: The effect of cataract and other media opacities on functional vision is typically assessed clinically using visual acuity. In both clinical and basic research, straylight (the functional result of light scattering in the eye) is commonly measured. The purpose of the present study was to

  4. Effects of Milk vs Dark Chocolate Consumption on Visual Acuity and Contrast Sensitivity Within 2 Hours: A Randomized Clinical Trial.

    Science.gov (United States)

    Rabin, Jeff C; Karunathilake, Nirmani; Patrizi, Korey

    2018-04-26

    Consumption of dark chocolate can improve blood flow, mood, and cognition in the short term, but little is known about the possible effects of dark chocolate on visual performance. To compare the short-term effects of consumption of dark chocolate with those of milk chocolate on visual acuity and large- and small-letter contrast sensitivity. A randomized, single-masked crossover design was used to assess short-term visual performance after consumption of a dark or a milk chocolate bar. Thirty participants without pathologic eye disease each consumed dark and milk chocolate in separate sessions, and within-participant paired comparisons were used to assess outcomes. Testing was conducted at the Rosenberg School of Optometry from June 25 to August 15, 2017. Visual acuity (in logMAR units) and large- and small-letter contrast sensitivity (in the log of the inverse of the minimum detectable contrast [logCS units]) were measured 1.75 hours after consumption of dark and milk chocolate bars. Among the 30 participants (9 men and 21 women; mean [SD] age, 26 [5] years), small-letter contrast sensitivity was significantly higher after consumption of dark chocolate (mean [SE], 1.45 [0.04] logCS) vs milk chocolate (mean [SE], 1.30 [0.05] logCS; mean improvement, 0.15 logCS [95% CI, 0.08-0.22 logCS]; P chocolate (mean [SE], 2.05 [0.02] logCS) vs milk chocolate (mean [SE], 2.00 [0.02] logCS; mean improvement, 0.05 logCS [95% CI, 0.00-0.10 logCS]; P = .07). Visual acuity improved slightly after consumption of dark chocolate (mean [SE], -0.22 [0.01] logMAR; visual acuity, approximately 20/12) and milk chocolate (mean [SE], -0.18 [0.01] logMAR; visual acuity, approximately 20/15; mean improvement, 0.04 logMAR [95% CI, 0.02-0.06 logMAR]; P = .05). Composite scores combining results from all tests showed significant improvement after consumption of dark compared with milk chocolate (mean improvement, 0.20 log U [95% CI, 0.10-0.30 log U]; P chocolate bar compared with a

  5. Visual acuity, self-reported vision and falls in the EPIC-Norfolk Eye study

    OpenAIRE

    Yip, Jennifer L Y; Khawaja, Anthony P; Broadway, David; Luben, Robert; Hayat, Shabina; Dalzell, Nichola; Bhaniani, Amit; Wareham, Nicholas; Khaw, Kay-Tee; Foster, Paul J

    2013-01-01

    Purpose To examine the relationship between visual acuity (VA) and self-reported vision (SRV) in relation to falls in 8317 participants of the European Prospective Investigation into Cancer-Norfolk Eye study. Methods All participants completed a health questionnaire that included a question regarding SRV and questions regarding the number of falls in the past year. Distance VA was measured using a logMAR chart for each eye. Poor SRV was defined as those reporting fair or poor distance vision....

  6. [Choroidal neovascularization followed in a patient with "Multiple Evanescent White Dot Syndrome" (MEWDS) -- a case report].

    Science.gov (United States)

    Löw, U; Palmowski, A M; Weich, C-M; Ruprecht, K W

    2004-12-01

    Since the description of the "multiple evanescent white dot syndrome" (MEWDS) by Jampol et al, choroiditis has been in the focus of interest. But the classical type of MEWDS was an exceptional case in clinical routine. A 48-year-old female presented to our hospital with a sudden unilateral visual acuity decrease and an extension of the blind spot. Ophthalmoscopy and fluorescein angiography revealed typical multiple grey-white chorioretinal patches of the same stage with lesion areas of about 100 - 200 microm compatible with the diagnose of MEWDS. Although visual acuity increased continuously the patient developed a classical choroidal neovascularization within 4 weeks. She was treated with PDT and visual acuity as well as the ophthalmoscopic diagnosis remained stable. In spite of visual improvement in MEWDS, regular control is recommended. In addition we propose to consider the diagnosis of MEWDS if an enlargement of the blind spot and CNV without lesions of the retinal pigment epithelium are diagnosed.

  7. Hearing acuity as a predictor of walking difficulties in older women.

    Science.gov (United States)

    Viljanen, Anne; Kaprio, Jaakko; Pyykkö, Ilmari; Sorri, Martti; Koskenvuo, Markku; Rantanen, Taina

    2009-12-01

    To examine whether hearing acuity correlates with walking ability and whether impaired hearing at baseline predicts new self-reported walking difficulties after 3 years. Prospective follow-up. Research laboratory and community. Four hundred thirty-four women aged 63 to 76. Hearing was measured using clinical audiometry. A person was defined as having a hearing impairment if a pure-tone average of thresholds at 0.5 to 4 kHz in the better ear was 21 dB or greater. Maximal walking speed was measured over 10 m (m/s), walking endurance as the distance (m), covered in 6 minutes and difficulties in walking 2 km according to self-report. At baseline, women with hearing impairment (n=179) had slower maximal walking speed (1.7 +/- 0.3 m/s vs 1.8 +/- 0.3 m/s, P=.007), lower walking endurance (520 +/- 75 m vs 536 +/- 75 m, P=.08), and more selfreported major difficulties in walking 2 km (12.8% vs 5.5%, P=.02) than those without hearing impairment. During follow-up, major walking difficulties developed for 33 participants. Women with hearing impairment at baseline had a twice the age-adjusted risk for new walking difficulties as those without hearing impairment (odds ratio=2.04, 95% confidence interval=0.96-4.33). Hearing acuity correlated with mobility, which may be explained by the association between impaired hearing and poor balance and greater risk for falls, both of which underlie decline in mobility. Prevention of hearing loss is not only important for the ability to communicate, but may also have more wide-ranging influences on functional ability.

  8. Health Benefits In 2016: Family Premiums Rose Modestly, And Offer Rates Remained Stable.

    Science.gov (United States)

    Claxton, Gary; Rae, Matthew; Long, Michelle; Damico, Anthony; Whitmore, Heidi; Foster, Gregory

    2016-10-01

    The annual Kaiser Family Foundation/Health Research and Educational Trust Employer Health Benefits Survey found that in 2016, average annual premiums (employer and worker contributions combined) were $6,435 for single coverage and $18,142 for family coverage. The family premium in 2016 was 3 percent higher than that in 2015. On average, workers contributed 18 percent of the premium for single coverage and 30 percent for family coverage. The share of firms offering health benefits (56 percent) and of workers covered by their employers' plans (62 percent) remained statistically unchanged from 2015. Employers continued to offer financial incentives for completing wellness or health promotion activities. Almost three in ten covered workers were enrolled in a high-deductible plan with a savings option-a significant increase from 2014. The 2016 survey included new questions on cost sharing for specialty drugs and on the prevalence of incentives for employees to seek care at alternative settings. Project HOPE—The People-to-People Health Foundation, Inc.

  9. Readers' Trust, Socio-Demographic, and Acuity Influences in Citizen Journalism Credibility for Disrupted Online Newspapers

    Science.gov (United States)

    Wester, Aaron Micah

    2013-01-01

    The purpose of this quantitative research study was to evaluate and determine if significant associations and linear correlations exist between reader socio-demographics, levels of trust and affinity in online citizen writer news story article content, brand loyalty, and acuity in newspaper organizations transitioning from print to online in a…

  10. Comparison of bromfenac 0.09% QD to nepafenac 0.1% TID after cataract surgery: pilot evaluation of visual acuity, macular volume, and retinal thickness at a single site

    Directory of Open Access Journals (Sweden)

    Cable M

    2012-07-01

    then rescued with bromfenac 0.09% QD and difluprednate 0.05% QD.Conclusion: Both bromfenac and nepafenac resulted in positive clinical outcomes of Early Treatment Diabetic Retinopathy Study visual acuities. Postoperative measurements of macular volume and retinal thickness of bromfenac subjects showed a trend toward improved vision, less retinal thickening, and more stable macular volumes overall.Keywords: NSAIDs, phacoemulsification, inflammation, cataract, macular volume, retinal thickness

  11. Stable glomerular filtration rate in normotensive IDDM patients with stable microalbuminuria. A 5-year prospective study

    DEFF Research Database (Denmark)

    Mathiesen, E R; Feldt-Rasmussen, B; Hommel, E

    1997-01-01

    patients with persistent microalbuminuria (mean urinary albumin excretion [UAE] 84 mg/24 h [range 30-300]) were followed prospectively for 5 years of clinical examinations that included the measurement of GFR (51Cr-labeled EDTA clearance) at least once a year. The mean GFR at baseline was 120 +/- 18 ml x....... Out of 40 patients, 14 progressed to diabetic nephropathy (UAE > 300 mg/24 h). These patients had a significant reduction in GFR (mean -2.2 +/- 3.8 ml x min-1 x year-1; P = 0.05), while GFR remained stable in the remaining 26 patients with nonprogressive microalbuminuria (change in GFR 0.5 +/- 2.1 ml...

  12. Hearing in alpacas (Vicugna pacos): audiogram, localization acuity, and use of binaural locus cues.

    Science.gov (United States)

    Heffner, Rickye S; Koay, Gimseong; Heffner, Henry E

    2014-02-01

    Behavioral audiograms and sound localization abilities were determined for three alpacas (Vicugna pacos). Their hearing at a level of 60 dB sound pressure level (SPL) (re 20 μPa) extended from 40 Hz to 32.8 kHz, a range of 9.7 octaves. They were most sensitive at 8 kHz, with an average threshold of -0.5 dB SPL. The minimum audible angle around the midline for 100-ms broadband noise was 23°, indicating relatively poor localization acuity and potentially supporting the finding that animals with broad areas of best vision have poorer sound localization acuity. The alpacas were able to localize low-frequency pure tones, indicating that they can use the binaural phase cue, but they were unable to localize pure tones above the frequency of phase ambiguity, thus indicating complete inability to use the binaural intensity-difference cue. In contrast, the alpacas relied on their high-frequency hearing for pinna cues; they could discriminate front-back sound sources using 3-kHz high-pass noise, but not 3-kHz low-pass noise. These results are compared to those of other hoofed mammals and to mammals more generally.

  13. The Joint Effects of Spatial Cueing and Transcranial Direct Current Stimulation on Visual Acuity

    Directory of Open Access Journals (Sweden)

    Taly Bonder

    2018-02-01

    Full Text Available The present study examined the mutual influence of cortical neuroenhancement and allocation of spatial attention on perception. Specifically, it explored the effects of transcranial Direct Current Stimulation (tDCS on visual acuity measured with a Landolt gap task and attentional precues. The exogenous cues were used to draw attention either to the location of the target or away from it, generating significant performance benefits and costs. Anodal tDCS applied to posterior occipital area for 15 min improved performance during stimulation, reflecting heightened visual acuity. Reaction times were lower, and accuracy was higher in the tDCS group, compared to a sham control group. Additionally, in post-stimulation trials tDCS significantly interacted with the effect of precuing. Reaction times were lower in valid cued trials (benefit and higher in invalid trials (cost compared to neutrally cued trials, the effect which was pronounced stronger in tDCS group than in sham control group. The increase of cost and benefit effects in the tDCS group was of a similar magnitude, suggesting that anodal tDCS influenced the overall process of attention orienting. The observed interaction between the stimulation of the visual cortex and precueing indicates a magnification of attention modulation.

  14. SMARTPHONE-BASED DILATED FUNDUS PHOTOGRAPHY AND NEAR VISUAL ACUITY TESTING AS INEXPENSIVE SCREENING TOOLS TO DETECT REFERRAL WARRANTED DIABETIC EYE DISEASE.

    Science.gov (United States)

    Toy, Brian C; Myung, David J; He, Lingmin; Pan, Carolyn K; Chang, Robert T; Polkinhorne, Alison; Merrell, Douglas; Foster, Doug; Blumenkranz, Mark S

    2016-05-01

    To compare clinical assessment of diabetic eye disease by standard dilated examination with data gathered using a smartphone-based store-and-forward teleophthalmology platform. 100 eyes of 50 adult patients with diabetes from a health care safety-net ophthalmology clinic. All patients underwent comprehensive ophthalmic examination. Concurrently, a smartphone was used to estimate near visual acuity and capture anterior and dilated posterior segment photographs, which underwent masked, standardized review. Quantitative comparison of clinic and smartphone-based data using descriptive, kappa, Bland-Altman, and receiver operating characteristic analyses was performed. Smartphone visual acuity was successfully measured in all eyes. Anterior and posterior segment photography was of sufficient quality to grade in 96 and 98 eyes, respectively. There was good correlation between clinical Snellen and smartphone visual acuity measurements (rho = 0.91). Smartphone-acquired fundus photographs demonstrated 91% sensitivity and 99% specificity to detect moderate nonproliferative and worse diabetic retinopathy, with good agreement between clinic and photograph grades (kappa = 0.91 ± 0.1, P smartphone-based telemedicine system that demonstrated sensitivity and specificity to detect referral-warranted diabetic eye disease as a proof-of-concept. Additional studies are warranted to evaluate this approach to expanding screening for diabetic retinopathy.

  15. Outcomes of visual acuity in carbon ion radiotherapy: Analysis of dose-volume histograms and prognostic factors

    International Nuclear Information System (INIS)

    Hasegawa, Azusa; Mizoe, Jun-etsu; Mizota, Atsushi; Tsujii, Hirohiko

    2006-01-01

    Purpose: To analyze the tolerance dose for retention of visual acuity in patients with head-and-neck tumors treated with carbon ion radiotherapy. Methods and Materials: From June 1994 to March 2000, 163 patients with tumors in the head and neck or skull base region were treated with carbon ion radiotherapy. Analysis was performed on 54 optic nerves (ONs) corresponding to 30 patients whose ONs had been included in the irradiated volume. These patients showed no evidence of visual impairment due to other factors and had a follow-up period of >4 years. All patients had been informed of the possibility of visual impairment before treatment. We evaluated the dose-complication probability and the prognostic factors for the retention of visual acuity in carbon ion radiotherapy, using dose-volume histograms and multivariate analysis. Results: The median age of 30 patients (14 men, 16 women) was 57.2 years. Median prescribed total dose was 56.0 gray equivalents (GyE) at 3.0-4.0 GyE per fraction per day (range, 48-64 GyE; 16-18 fractions; 4-6 weeks). Of 54 ONs that were analyzed, 35 had been irradiated with max ]) resulting in no visual loss. Conversely, 11 of the 19 ONs (58%) irradiated with >57 GyE (D max ) suffered a decrease of visual acuity. In all of these cases, the ONs had been involved in the tumor before carbon ion radiotherapy. In the multivariate analysis, a dose of 20% of the volume of the ON (D 2 ) was significantly associated with visual loss. Conclusions: The occurrence of visual loss seems to be correlated with a delivery of >60 GyE to 20% of the volume of the ON

  16. The Cost-effectiveness of Welcome to Medicare Visual Acuity Screening and a Possible Alternative Welcome to Medicare Eye Evaluation Among Persons Without Diagnosed Diabetes Mellitus

    Science.gov (United States)

    Rein, David B.; Wittenborn, John S.; Zhang, Xinzhi; Hoerger, Thomas J.; Zhang, Ping; Klein, Barbara Eden Kobrin; Lee, Kris E.; Klein, Ronald; Saaddine, Jinan B.

    2013-01-01

    Objective To estimate the cost-effectiveness of visual acuity screening performed in primary care settings and of dilated eye evaluations performed by an eye care professional among new Medicare enrollees with no diagnosed eye disorders. Medicare currently reimburses visual acuity screening for new enrollees during their initial preventive primary care health check, but dilated eye evaluations may be a more cost-effective policy. Design Monte Carlo cost-effectiveness simulation model with a total of 50 000 simulated patients with demographic characteristics matched to persons 65 years of age in the US population. Results Compared with no screening policy, dilated eye evaluations increased quality-adjusted life-years (QALYs) by 0.008 (95% credible interval [CrI], 0.005–0.011) and increased costs by $94 (95% CrI, −$35 to $222). A visual acuity screening increased QALYs in less than 95% of the simulations (0.001 [95% CrI, −0.002 to 0.004) and increased total costs by $32 (95% CrI, −$97 to $159) per person. The incremental cost-effectiveness ratio of a visual acuity screening and an eye examination compared with no screening were $29 000 and $12 000 per QALY gained, respectively. At a willingness-to-pay value of $15 000 or more per QALY gained, a dilated eye evaluation was the policy option most likely to be cost-effective. Conclusions The currently recommended visual acuity screening showed limited efficacy and cost-effectiveness compared with no screening. In contrast, a new policy of reimbursement for Welcome to Medicare dilated eye evaluations was highly cost-effective. PMID:22232367

  17. Subconjunctival sirolimus in the treatment of diabetic macular edema.

    Science.gov (United States)

    Krishnadev, Nupura; Forooghian, Farzin; Cukras, Catherine; Wong, Wai; Saligan, Leorey; Chew, Emily Y; Nussenblatt, Robert; Ferris, Frederick; Meyerle, Catherine

    2011-11-01

    Diabetic macular edema (DME) is a leading cause of blindness in the developed world. Sirolimus has been shown to inhibit the production, signaling, and activity of many growth factors relevant to the development of diabetic retinopathy. This phase I/II study assesses the safety of multiple subconjunctival sirolimus injections for the treatment of DME, with some limited efficacy data. In this phase I/II prospective, open-label pilot study, five adult participants with diabetic macular edema involving the center of the fovea and best-corrected ETDRS visual acuity score of ≤74 letters (20/32 or worse) received 20 μl (440 μg) of subconjunctival sirolimus at baseline, month 2 and every 2 months thereafter, unless there was resolution of either retinal thickening on OCT or leakage on fluorescein angiography. Main outcome measures included best-corrected visual acuity and central retinal thickness on OCT at 6 months and 1 year, as well as safety outcomes. Repeated subconjunctival sirolimus injections were well-tolerated, with no significant drug-related adverse events. There was no consistent treatment effect related to sirolimus; one participant experienced a 2-line improvement in visual acuity and 2 log unit decrease in retinal thickness at 6 months and 1 year, two remained essentially stable, one had stable visual acuity but improvement of central retinal thickness of 1 and 3 log units at 6 months and 1 year respectively, and one had a 2-line worsening of visual acuity and a 1 log unit increase in retinal thickness at 6 months and 1 year. Results in the fellow eyes with diabetic macular edema, not treated with sirolimus, were similar. Subconjunctival sirolimus appears safe to use in patients with DME. Assessment of possible treatment benefit will require a randomized trial.

  18. Long-term visual acuity, retention and complications observed with the type-I and type-II Boston keratoprostheses in an Irish population.

    Science.gov (United States)

    Duignan, E S; Ní Dhubhghaill, S; Malone, C; Power, W

    2016-08-01

    To evaluate the outcomes of the type-I and type-II Boston keratoprostheses in a single Irish centre. A retrospective chart review of keratoprosthesis implantations carried out in our institution from November 2002 to March 2014 was performed. All procedures were performed by a single surgeon (WP). Thirty-four keratoprosthesis implantations were carried out in 31 patients with a mean follow-up of 42±31 months (range 2-110 months). Seventeen patients were female (54.8%) and 14 were male (45.2%). The majority of keratoprostheses implanted were type-I (31/34, 91.2%), and three were type-II (3/34, 8.8%). Twenty-nine patients (85.3%) had an improvement in distance best-corrected visual acuity (BCVA) from baseline. Fifty per cent (17/34) of patients had a best-ever BCVA of at least 6/12. Eighteen patients (64.3%) retained a BCVA of at least 6/60 at 1 year. Over the course of follow-up, six keratoprostheses were explanted from six eyes of five patients, one of which was a type-II keratoprosthesis. Twenty-six patients (76.5%) developed postoperative complications. Complications included retroprosthetic membrane (18 patients, 52.9%), an exacerbation or new diagnosis of glaucoma (6 patients, 17.6%), endophthalmitis (5 patients, 14.7%) and retinal detachment (2 patients, 5.9%). These data demonstrate excellent visual acuity and retention outcomes in a cohort with a long follow-up period in a single centre. Complications remain a considerable source of morbidity. These outcomes provide further evidence for the long-term stability of type-I and type-II Boston keratoprostheses in the management of patients in whom a traditional graft is likely to fail. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Cognitive performance of detoxified alcoholic Korsakoff syndrome patients remains stable over two years.

    Science.gov (United States)

    Fujiwara, Esther; Brand, Matthias; Borsutzky, Sabine; Steingass, Hans-P; Markowitsch, Hans J

    2008-07-01

    Excessive alcohol consumption is assumed to promote cognitive decline, eventually increasing the risk of dementia. However, little is known about the time course of cognitive functions in patients with chronic alcoholic Korsakoff syndrome (KS). Therefore, we assessed neuropsychological performance in 20 detoxified chronic KS inpatients at time 1 (T1) with a follow-up after two years (T2). The neuropsychological tests assessed verbal and visual short- and long-term memory, working memory, basic executive functions, language, general knowledge, and visual-spatial abilities. Surveys with caregivers and medical records provided information about current and previous disease-related parameters, drinking history, additional pathologies, as well as psychosocial and cognitive therapy within the two-year period. At both sessions, the majority of the KS patients' results were inferior to those of normal subjects. Comparing T1 and T2 revealed no significant decline in any of the investigated functions. Instead, general knowledge, visual long-term memory, and verbal fluency improved slightly after two years, though they still remained within pathological range. Comparing most improved and most deteriorated patients, better outcome occurred more frequently in men than women and was associated with higher premorbid education and fewer detoxifications in the past. In this sample of detoxified KS patients there was no indication of accelerated cognitive decline or onset of dementia-like symptoms over two years.

  20. The human vascular endothelial cell line HUV-EC-C harbors the integrated HHV-6B genome which remains stable in long term culture.

    Science.gov (United States)

    Shioda, Setsuko; Kasai, Fumio; Ozawa, Midori; Hirayama, Noriko; Satoh, Motonobu; Kameoka, Yousuke; Watanabe, Ken; Shimizu, Norio; Tang, Huamin; Mori, Yasuko; Kohara, Arihiro

    2018-02-01

    Human herpes virus 6 (HHV-6) is a common human pathogen that is most often detected in hematopoietic cells. Although human cells harboring chromosomally integrated HHV-6 can be generated in vitro, the availability of such cell lines originating from in vivo tissues is limited. In this study, chromosomally integrated HHV-6B has been identified in a human vascular endothelial cell line, HUV-EC-C (IFO50271), derived from normal umbilical cord tissue. Sequence analysis revealed that the viral genome was similar to the HHV-6B HST strain. FISH analysis using a HHV-6 DNA probe showed one signal in each cell, detected at the distal end of the long arm of chromosome 9. This was consistent with a digital PCR assay, validating one copy of the viral DNA. Because exposure of HUV-EC-C to chemicals did not cause viral reactivation, long term cell culture of HUV-EC-C was carried out to assess the stability of viral integration. The growth rate was altered depending on passage numbers, and morphology also changed during culture. SNP microarray profiles showed some differences between low and high passages, implying that the HUV-EC-C genome had changed during culture. However, no detectable change was observed in chromosome 9, where HHV-6B integration and the viral copy number remained unchanged. Our results suggest that integrated HHV-6B is stable in HUV-EC-C despite genome instability.

  1. Fundamentals of the LISA stable flight formation

    International Nuclear Information System (INIS)

    Dhurandhar, S V; Nayak, K Rajesh; Koshti, S; Vinet, J-Y

    2005-01-01

    The joint NASA-ESA mission, LISA, relies crucially on the stability of the three-spacecraft constellation. Each of the spacecraft is in heliocentric orbit forming a stable triangle. In this paper we explicitly show with the help of the Clohessy-Wiltshire equations that any configuration of spacecraft lying in the planes making angles of ±60 0 with the ecliptic and given suitable initial velocities within the plane, can be made stable in the sense that the inter-spacecraft distances remain constant to first order in the dimensions of the configuration compared with the distance to the Sun. Such analysis would be useful in order to carry out theoretical studies on the optical links, simulators, etc

  2. Stable convergence and stable limit theorems

    CERN Document Server

    Häusler, Erich

    2015-01-01

    The authors present a concise but complete exposition of the mathematical theory of stable convergence and give various applications in different areas of probability theory and mathematical statistics to illustrate the usefulness of this concept. Stable convergence holds in many limit theorems of probability theory and statistics – such as the classical central limit theorem – which are usually formulated in terms of convergence in distribution. Originated by Alfred Rényi, the notion of stable convergence is stronger than the classical weak convergence of probability measures. A variety of methods is described which can be used to establish this stronger stable convergence in many limit theorems which were originally formulated only in terms of weak convergence. Naturally, these stronger limit theorems have new and stronger consequences which should not be missed by neglecting the notion of stable convergence. The presentation will be accessible to researchers and advanced students at the master's level...

  3. Improvement of visual acuity and VEP after optic nerve contusion by NGF and its safety analysis

    Directory of Open Access Journals (Sweden)

    Ming Zhao

    2018-02-01

    Full Text Available AIM:To investigate the effect of neuropathic factor(NGFon visual acuity and visual evoked potential(VEPin patients with optic nerve contusion. METHODS:Totally 78 patients(78 eyeswith optic nerve contusion were selected. From January 2013 to June 2016, 39 cases(39 eyeswere divided into observation group and control group respectively according to the random number table method. Prednisone, vitamins and mecobalamin tablets treatment were given to both groups, based on that, the observation group was given NGF treatment, continuous treatment of 2 courses(21d for a course of treatment. RESULTS: There was no significant difference in visual field defect and visual field sensitivity between the observation group and the control group before treatment(P>0.05. After treatment, the visual field defect degree of the observation group was smaller, the visual field sensitivity was better than that of the control group(PP>0.05. After treatment, the P100 wave latency of the observation group was significantly shorter than that of the control group(PPPCONCLUSION: NGF treatment for optic nerve contusion can significantly improve the patient's visual acuity, VEP indicators, reduce visual field defects, improve visual field sensitivity.

  4. Non-labile silver species in biosolids remain stable throughout 50 years of weathering and ageing

    International Nuclear Information System (INIS)

    Donner, E.; Scheckel, K.; Sekine, R.; Popelka-Filcoff, R.S.; Bennett, J.W.; Brunetti, G.; Naidu, R.; McGrath, S.P.; Lombi, E.

    2015-01-01

    Increasing commercial use of nanosilver has focussed attention on the fate of silver (Ag) in the wastewater release pathway. This paper reports the speciation and lability of Ag in archived, stockpiled, and contemporary biosolids from the UK, USA and Australia, and indicates that biosolids Ag concentrations have decreased significantly over recent decades. XANES revealed the importance of reduced-sulfur binding environments for Ag speciation in materials ranging from freshly produced sludge to biosolids weathered under ambient environmental conditions for more than 50 years. Isotopic dilution with 110m Ag showed that Ag was predominantly non-labile in both fresh and aged biosolids (13.7% mean lability), with E-values ranging from 0.3 to 60 mg/kg and 5 mM CaNO 3 extractable Ag from 1.2 to 609 μg/kg (0.002–3.4% of the total Ag). This study indicates that at the time of soil application, biosolids Ag will be predominantly Ag-sulfides and characterised by low isotopic lability. - Highlights: • Biosolids silver (Ag) concentrations appear to have decreased in recent decades. • Ag 2 S dominates Ag speciation in freshly produced sludge. • Ag 2 S is also the dominant species in aged biosolids. • Upon land application biosolids will mainly contain Ag-sulfides and have low isotopic lability. - Analysis of historic and contemporary biosolids from three continents indicated decreasing wastewater silver releases, and non-labile, extremely stable silver speciation

  5. Higher-order aberrations and best-corrected visual acuity in Native American children with a high prevalence of astigmatism.

    Science.gov (United States)

    Miller, Joseph M; Harvey, Erin M; Schwiegerling, Jim

    2015-08-01

    To determine whether higher-order aberrations (HOAs) in children from a highly astigmatic population differ from population norms and whether HOAs are associated with astigmatism and reduced best-corrected visual acuity. Subjects were 218 Tohono O'odham Native American children 5-9 years of age. Noncycloplegic HOA measurements were obtained with a handheld Shack-Hartmann sensor (SHS). Signed (z06s to z14s) and unsigned (z06u to z14u) wavefront aberration Zernike coefficients Z(3,-3) to Z(4,4) were rescaled for a 4 mm diameter pupil and compared to adult population norms. Cycloplegic refraction and best-corrected logMAR letter visual acuity (BCVA) were also measured. Regression analyses assessed the contribution of astigmatism (J0) and HOAs to BCVA. The mean root-mean-square (RMS) HOA of 0.191 ± 0.072 μm was significantly greater than population norms (0.100 ± 0.044 μm). All unsigned HOA coefficients (z06u to z14u) and all signed coefficients except z09s, z10s, and z11s were significantly larger than population norms. Decreased BCVA was associated with astigmatism (J0) and spherical aberration (z12u) but not RMS coma, with the effect of J0 about 4 times as great as z12u. Tohono O'odham children show elevated HOAs compared to population norms. Astigmatism and unsigned spherical aberration are associated with decreased acuity, but the effects of spherical aberration are minimal and not clinically significant. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  6. Spontaneous Regression of Choroidal Neovascularization in a Patient with Pattern Dystrophy

    Directory of Open Access Journals (Sweden)

    Anastasios Anastasakis

    2016-01-01

    Full Text Available Purpose. To present a case of a patient with pattern dystrophy (PD associated choroidal neovascularization (CNV that resolved spontaneously without treatment. Methods. A 69-year-old male patient was referred to our unit, for evaluation of a recent visual loss (metamorphopsias in his left eye. Fundus examination, fundus autofluorescence imaging, and fluorescein angiography showed a choroidal neovascular membrane in his left eye. Since visual acuity was satisfactory the patient elected observation. Clinical examination and OCT testing were repeated at 6 and 12 months after presentation. Results. Visual acuity remained stable at the level of 0.9 (baseline BCVA during the follow-up period (12 months. Repeat OCT testing showed complete spontaneous regression of the choroidal neovascular membrane without evidence of intra- or subretinal fluid in both follow-up visits. Conclusions. Spontaneous regression of choroidal neovascularization can occur in patients with retinal dystrophies and associated choroidal neovascular membranes. The decision to treat or observe these patients relies strongly on the presenting visual acuity, since, in isolated instances, spontaneous resolution of choroidal neovascularization may occur.

  7. A cross-sectional examination of visual acuity by specific type of albinism.

    Science.gov (United States)

    Winsor, Caitlin Nosanov; Holleschau, Ann M; Connett, John E; Summers, C Gail

    2016-10-01

    Reports of best-corrected visual acuity (BCVA) in albinism are often based on overlapping clinical phenotypes. BCVA in albinism has been shown to improve with age. This study reports a large cross-sectional investigation to determine whether BCVA differs by specific type of albinism when age-corrected. This retrospective review identified 170 individuals with a specific type of albinism identified by mutation(s) in a gene known to cause albinism (for OCA1, OCA2, and Hermansky-Pudlak syndrome ([HPS]) or a specific phenotype (white hair and no melanin pigment in OCA1A; pigmentary mosaicism in the obligate carriers for males with OA1). We recorded optotype binocular BCVA at final follow-up. Patients were age-grouped (2-5 years, 6-14 years, and ≥15 years) for comparison. The greatest visual acuity deficit was found for OCA1A in all age groups. At age ≥15 years (n = 79), mean BCVA was 20/128 for OCA1A, 20/37 for OCA1B, 20/59 for OCA2, 20/63 for OA1, and 20/121 for HPS. Significant differences between BCVA at ≥15 years were found in the following: OCA1A vs OCA1B, OCA1A vs OCA2, OCA1A vs OA1, OCA1B vs HPS, OCA2 vs HPS, and OA1 vs HPS (P ≤ 0.02). This study provides a large sample size and includes only those with a specific type of albinism. BCVA varies by albinism type, and there is overlap in BCVA, particularly in the younger age groups. For ages ≥15 years, there are significant differences in BCVA between several types of albinism. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  8. The contributions of numerical acuity and non-numerical stimulus features to the development of the number sense and symbolic math achievement.

    Science.gov (United States)

    Starr, Ariel; DeWind, Nicholas K; Brannon, Elizabeth M

    2017-11-01

    Numerical acuity, frequently measured by a Weber fraction derived from nonsymbolic numerical comparison judgments, has been shown to be predictive of mathematical ability. However, recent findings suggest that stimulus controls in these tasks are often insufficiently implemented, and the proposal has been made that alternative visual features or inhibitory control capacities may actually explain this relation. Here, we use a novel mathematical algorithm to parse the relative influence of numerosity from other visual features in nonsymbolic numerical discrimination and to examine the strength of the relations between each of these variables, including inhibitory control, and mathematical ability. We examined these questions developmentally by testing 4-year-old children, 6-year-old children, and adults with a nonsymbolic numerical comparison task, a symbolic math assessment, and a test of inhibitory control. We found that the influence of non-numerical features decreased significantly over development but that numerosity was a primary determinate of decision making at all ages. In addition, numerical acuity was a stronger predictor of math achievement than either non-numerical bias or inhibitory control in children. These results suggest that the ability to selectively attend to number contributes to the maturation of the number sense and that numerical acuity, independent of inhibitory control, contributes to math achievement in early childhood. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A binocular iPad treatment for amblyopic children.

    Science.gov (United States)

    Li, S L; Jost, R M; Morale, S E; Stager, D R; Dao, L; Stager, D; Birch, E E

    2014-10-01

    Monocular amblyopia treatment (patching or penalization) does not always result in 6/6 vision and amblyopia often recurs. As amblyopia arises from abnormal binocular visual experience, we evaluated the effectiveness of a novel home-based binocular amblyopia treatment. Children (4-12 y) wore anaglyphic glasses to play binocular games on an iPad platform for 4 h/w for 4 weeks. The first 25 children were assigned to sham games and then 50 children to binocular games. Children in the binocular group had the option of participating for an additional 4 weeks. Compliance was monitored with calendars and tracking fellow eye contrast settings. About half of the children in each group were also treated with patching at a different time of day. Best-corrected visual acuity, suppression, and stereoacuity were measured at baseline, at the 4- and 8-week outcome visits, and 3 months after cessation of treatment. Mean (±SE) visual acuity improved in the binocular group from 0.47±0.03 logMAR at baseline to 0.39±0.03 logMAR at 4 weeks (P<0.001); there was no significant change for the sham group. The effect of binocular games on visual acuity did not differ for children who were patched vs those who were not. The median stereoacuity remained unchanged in both groups. An additional 4 weeks of treatment did not yield additional visual acuity improvement. Visual acuity improvements were maintained for 3 months after the cessation of treatment. Binocular iPad treatment rapidly improved visual acuity, and visual acuity was stable for at least 3 months following the cessation of treatment.

  10. France's Administrative Tertiary: Stable Numbers for Occupations in Flux.

    Science.gov (United States)

    Liaroutzos, Olivier; Meriot, Sylvie-Anne

    1995-01-01

    During the past decade, the number of jobs in France's administrative service sector has remained stable. General administrative work has become more infrequent; however, the basic occupations of secretary and accountancy have been maintained. Although the number of typists has declined, the number of "secretarial" jobs has increased…

  11. Individual Differences in Scotopic Visual Acuity and Contrast Sensitivity: Genetic and Non-Genetic Influences.

    Directory of Open Access Journals (Sweden)

    Alex J Bartholomew

    Full Text Available Despite the large amount of variation found in the night (scotopic vision capabilities of healthy volunteers, little effort has been made to characterize this variation and factors, genetic and non-genetic, that influence it. In the largest population of healthy observers measured for scotopic visual acuity (VA and contrast sensitivity (CS to date, we quantified the effect of a range of variables on visual performance. We found that young volunteers with excellent photopic vision exhibit great variation in their scotopic VA and CS, and this variation is reliable from one testing session to the next. We additionally identified that factors such as Circadian preference, iris color, astigmatism, depression, sex and education have no significant impact on scotopic visual function. We confirmed previous work showing that the amount of time spent on the vision test influences performance and that laser eye surgery results in worse scotopic vision. We also showed a significant effect of intelligence and photopic visual performance on scotopic VA and CS, but all of these variables collectively explain <30% of the variation in scotopic vision. The wide variation seen in young healthy volunteers with excellent photopic vision, the high test-retest agreement, and the vast majority of the variation in scotopic vision remaining unexplained by obvious non-genetic factors suggests a strong genetic component. Our preliminary genome-wide association study (GWAS of 106 participants ruled out any common genetic variants of very large effect and paves the way for future, larger genetic studies of scotopic vision.

  12. Accuracy of 'My Gut Feeling:' Comparing System 1 to System 2 Decision-Making for Acuity Prediction, Disposition and Diagnosis in an Academic Emergency Department.

    Science.gov (United States)

    Cabrera, Daniel; Thomas, Jonathan F; Wiswell, Jeffrey L; Walston, James M; Anderson, Joel R; Hess, Erik P; Bellolio, M Fernanda

    2015-09-01

    Current cognitive sciences describe decision-making using the dual-process theory, where a System 1 is intuitive and a System 2 decision is hypothetico-deductive. We aim to compare the performance of these systems in determining patient acuity, disposition and diagnosis. Prospective observational study of emergency physicians assessing patients in the emergency department of an academic center. Physicians were provided the patient's chief complaint and vital signs and allowed to observe the patient briefly. They were then asked to predict acuity, final disposition (home, intensive care unit (ICU), non-ICU bed) and diagnosis. A patient was classified as sick by the investigators using previously published objective criteria. We obtained 662 observations from 289 patients. For acuity, the observers had a sensitivity of 73.9% (95% CI [67.7-79.5%]), specificity 83.3% (95% CI [79.5-86.7%]), positive predictive value 70.3% (95% CI [64.1-75.9%]) and negative predictive value 85.7% (95% CI [82.0-88.9%]). For final disposition, the observers made a correct prediction in 80.8% (95% CI [76.1-85.0%]) of the cases. For ICU admission, emergency physicians had a sensitivity of 33.9% (95% CI [22.1-47.4%]) and a specificity of 96.9% (95% CI [94.0-98.7%]). The correct diagnosis was made 54% of the time with the limited data available. System 1 decision-making based on limited information had a sensitivity close to 80% for acuity and disposition prediction, but the performance was lower for predicting ICU admission and diagnosis. System 1 decision-making appears insufficient for final decisions in these domains but likely provides a cognitive framework for System 2 decision-making.

  13. Visual Acuity Is Correlated with the Area of the Foveal Avascular Zone in Diabetic Retinopathy and Retinal Vein Occlusion.

    Science.gov (United States)

    Balaratnasingam, Chandrakumar; Inoue, Maiko; Ahn, Seungjun; McCann, Jesse; Dhrami-Gavazi, Elona; Yannuzzi, Lawrence A; Freund, K Bailey

    2016-11-01

    To determine if the area of the foveal avascular zone (FAZ) is correlated with visual acuity (VA) in diabetic retinopathy (DR) and retinal vein occlusion (RVO). Cross-sectional study. Ninety-five eyes of 66 subjects with DR (65 eyes), branch retinal vein occlusion (19 eyes), and central retinal vein occlusion (11 eyes). Structural optical coherence tomography (OCT; Spectralis, Heidelberg Engineering) and OCT angiography (OCTA; Avanti, Optovue RTVue XR) data from a single visit were analyzed. FAZ area, point thickness of central fovea, central 1-mm subfield thickness, the occurrence of intraretinal cysts, ellipsoid zone disruption, and disorganization of retinal inner layers (DRIL) length were measured. VA was also recorded. Correlations between FAZ area and VA were explored using regression models. Main outcome measure was VA. Mean age was 62.9±13.2 years. There was no difference in demographic and OCT-derived anatomic measurements between branch retinal vein occlusion and central retinal vein occlusion groups (all P ≥ 0.058); therefore, data from the 2 groups were pooled together to a single RVO group for further statistical comparisons. Univariate and multiple regression analysis showed that the area of the FAZ was significantly correlated with VA in DR and RVO (all P ≤ 0.003). The relationship between FAZ area and VA varied with age (P = 0.026) such that for a constant FAZ area, an increase in patient age was associated with poorer vision (rise in logarithm of the minimum angle of resolution visual acuity). Disruption of the ellipsoid zone was significantly correlated with VA in univariate and multiple regression analysis (both P < 0.001). Occurrence of intraretinal cysts, DRIL length, and lens status were significantly correlated with VA in the univariate regression analysis (P ≤ 0.018) but not the multiple regression analysis (P ≥ 0.210). Remaining variables evaluated in this study were not predictive of VA (all P ≥ 0.225). The area of the FAZ is

  14. Changes in visual acuity in patients with wet age-related macular degeneration treated with intravitreal ranibizumab in daily clinical practice: the LUMIERE study.

    Science.gov (United States)

    Cohen, Salomon Y; Mimoun, Gerard; Oubraham, Hassiba; Zourdani, Alain; Malbrel, Christian; Queré, Stephane; Schneider, Véronique

    2013-03-01

    To survey compliance with recommended intravitreal ranibizumab treatment protocols in daily clinical practice in France, with reference to outcomes. A retrospective, descriptive, observational study in patients with subfoveal wet age-related macular degeneration treated with ranibizumab. All historical data for the study period, including demographic, treatment, and disease details and visual acuity measurements (baseline, Month 3, and Month 12), were recorded retrospectively at least 12 months after the beginning of treatment. In 551 patients followed by 16 ophthalmologists, 12 months of intravitreal ranibizumab treatment induced a mean visual acuity gain of 3.2 ± 14.8 Early Treatment Diabetic Retinopathy Study-equivalent letters. Fewer than 40% of patients received the recommended treatment of initial 3 monthly injections. More than 50% had to wait >8 days between diagnosis and treatment. At Month 3, visual acuity gain was greater in patients who had received recommended induction and in whom treatment was initiated quickly. At Month 12, the induction-related effect had largely disappeared but the time-to-treatment effect persisted. Patients had an average of 5.1 injections (2.6 during induction period). No patients were monitored monthly as stipulated in the guidelines. Although poor compliance with recommendations has been reflected in mediocre outcomes, there is evidence that practice is improving.

  15. Stable isotope geochemistry : definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2005-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeoclimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. (author). 52 refs., 11 figs., 2 tabs

  16. Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity.

    Science.gov (United States)

    Koefoed, Vilhelm F; Baste, Valborg; Roumes, Corinne; Høvding, Gunnar

    2015-03-01

    This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03). The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.

  17. Leaf water stable isotopes and water transport outside the xylem.

    Science.gov (United States)

    Barbour, M M; Farquhar, G D; Buckley, T N

    2017-06-01

    How water moves through leaves, and where the phase change from liquid to vapour occurs within leaves, remain largely mysterious. Some time ago, we suggested that the stable isotope composition of leaf water may contain information on transport pathways beyond the xylem, through differences in the development of gradients in enrichment within the various pathways. Subsequent testing of this suggestion provided ambiguous results and even questioned the existence of gradients in enrichment within the mesophyll. In this review, we bring together recent theoretical developments in understanding leaf water transport pathways and stable isotope theory to map a path for future work into understanding pathways of water transport and leaf water stable isotope composition. We emphasize the need for a spatially, anatomically and isotopically explicit model of leaf water transport. © 2016 John Wiley & Sons Ltd.

  18. Ranking stability and super-stable nodes in complex networks.

    Science.gov (United States)

    Ghoshal, Gourab; Barabási, Albert-László

    2011-07-19

    Pagerank, a network-based diffusion algorithm, has emerged as the leading method to rank web content, ecological species and even scientists. Despite its wide use, it remains unknown how the structure of the network on which it operates affects its performance. Here we show that for random networks the ranking provided by pagerank is sensitive to perturbations in the network topology, making it unreliable for incomplete or noisy systems. In contrast, in scale-free networks we predict analytically the emergence of super-stable nodes whose ranking is exceptionally stable to perturbations. We calculate the dependence of the number of super-stable nodes on network characteristics and demonstrate their presence in real networks, in agreement with the analytical predictions. These results not only deepen our understanding of the interplay between network topology and dynamical processes but also have implications in all areas where ranking has a role, from science to marketing.

  19. Using the Five-Level Taiwan Triage and Acuity Scale Computerized System: Factors in Decision Making by Emergency Department Triage Nurses.

    Science.gov (United States)

    Chang, Wen; Liu, Hsueh-Erh; Goopy, Suzanne; Chen, Li-Chin; Chen, Hsiao-Jung; Han, Chin-Yen

    2017-10-01

    Triage classifies and prioritizes patients' care based on the acuity of the illness in emergency departments (EDs). In Taiwan, the five-level Taiwan Triage and Acuity Scale (TTAS) computerized system was implemented nationally in 2010. The purpose of this study was to understand which factors affect decision-making practices of triage nurses in the light of the implementation of the new TTAS tool and computerized system. The qualitative data were collected by in-depth interviews. Data saturation was reached with 16 participants. Content analysis was used. The results demonstrated that the factors affecting nurses' decision making in the light of the newly implemented computerized system sit within three main categories: external environmental, patients' health status, and nurses' experiences. This study suggests ensuring the patient's privacy while attending the triage desk, improving the critical thinking of triage nurses, and strengthening the public's understanding of the ED visits. These will make ED triage more efficient.

  20. England and Wales: Stable fertility and pronounced social status differences

    Directory of Open Access Journals (Sweden)

    Wendy Sigle-Rushton

    2008-07-01

    Full Text Available For nearly three decades, the total fertility rate in England and Wales has remained high relative to other European countries, and stable at about 1.7 births per woman. In this chapter, we examine trends in both period and cohort fertility throughout the twentieth century, and demonstrate some important differences across demographic and social groups in the timing and quantum of fertility. Breaking with a market-oriented and laissez-faire approach to work and family issues, the last 10 years have seen the introduction of new social and economic policies aimed at providing greater support to families with children. However, the effect of the changes is likely to be limited to families on the lower end of the income scale. Rather than facilitating work and parenthood, some policies create incentives for a traditional gendered division of labour. Fertility appears to have remained stable despite, rather than because of, government actions.

  1. On The Roman Domination Stable Graphs

    Directory of Open Access Journals (Sweden)

    Hajian Majid

    2017-11-01

    Full Text Available A Roman dominating function (or just RDF on a graph G = (V,E is a function f : V → {0, 1, 2} satisfying the condition that every vertex u for which f(u = 0 is adjacent to at least one vertex v for which f(v = 2. The weight of an RDF f is the value f(V (G = Pu2V (G f(u. The Roman domination number of a graph G, denoted by R(G, is the minimum weight of a Roman dominating function on G. A graph G is Roman domination stable if the Roman domination number of G remains unchanged under removal of any vertex. In this paper we present upper bounds for the Roman domination number in the class of Roman domination stable graphs, improving bounds posed in [V. Samodivkin, Roman domination in graphs: the class RUV R, Discrete Math. Algorithms Appl. 8 (2016 1650049].

  2. Visual acuity after Ruthenium106 brachytherapy of choroidal melanomas

    International Nuclear Information System (INIS)

    Damato, Bertil; Patel, Imran M.; Campbell, Ian R.; Mayles, Helen M.; Errington, R. Douglas

    2005-01-01

    Purpose: To report on conservation of visual acuity after Ruthenium 106 (Ru-106) brachytherapy of choroidal melanoma. Methods and materials: This study was a noncomparative interventional case series of 458 patients with choroidal melanoma treated at a single center between January 1993 and December 2001. The intervention consisted of Ru-106 brachytherapy delivering minimum scleral and apex doses of 300 Gy and 80 Gy, respectively, using a 15-mm or 20-mm plaque. For discrete, posterior tumors, the plaque was positioned eccentrically with its posterior edge aligned with the posterior tumor margin. To ensure correct plaque positioning, any overlying extraocular muscles were dis-inserted, and the locations of both tumor and plaque edges were confirmed by transillumination and indentation. The main outcome measures were conservation of vision of 20/40 or better, 20/200 or better, and Counting Fingers or better, according to baseline variables. Results: The actuarial rate of conservation of 20/40 or better was 55% at 9 years, loss of such vision correlating with posterior tumor extension (p 106 brachytherapy of posterior choroidal melanoma achieves good conservation of vision if the tumor does not extend close to the optic nerve or fovea

  3. COMPARISON OF VISUAL ACUITY IN REDUCED LUMINATION AND FACILITY OF OCULAR ACCOMMODATION IN TABLE TENNIS CHAMPIONS AND NON- PLAYERS

    Directory of Open Access Journals (Sweden)

    Ebrahim Jafarzadehpur

    2004-03-01

    Full Text Available A table tennis player should fixate at different distances; track the objects with different speed, and in different visual environment. Their visual skills must be well developed for these capabilities. Therefore, visual acuity in reduced lumination and facility of ocular accommodation those are two criteria for visual skills have been compared in table tennis players and normal non-players. Twenty-nine young table tennis champions and 29 normal matched non-players (did not take part in any racket sports game were evaluated. Basic visual and eye examinations were done for both of them. Normal results in basic examination were fundamental requirement for all the subjects. +/-2.00 sphere lenses for accommodation facility are used. An electrical current regulator changed the output light intensity of a conventional chart projector (Topcon. Light intensity decreased to 10 cd·m-2 and visual acuity tested. In comparison of visual acuity in reduced lumination and facility of ocular accommodation in table tennis champions and non-players there are significant differences (p < 0.001. In the preliminary visual tests there was not any significant different in the two groups but the results in the top level table tennis player was very uniform and in every test and the standard deviation was lesser in tennis player group than non-players. These results show that motor and sensorial functions of expert players are well developed. That is consistent with other researchers. This result was interpreted as reflecting a better perceptual system of experts to the constraints encountered during table tennis and its use in practical settings for evaluating athletes or detecting sport talents. However some visual and perceptual training that usually used in orthoptics can be used for novice table tennis player to improve their abilities

  4. Acuidade visual: Medidas e notações Visual acuity: Measurements and notations

    Directory of Open Access Journals (Sweden)

    Harley E. A. Bicas

    2002-06-01

    Full Text Available Avaliações da função visual são muito complexas por dependerem de mecanismos aferentes, eferentes e cognitivos, além de fatores externos à pessoa examinada, como o tipo de estímulo e o de sua apresentação. O exame da acuidade visual é discutido em seus aspectos formais de definições, quantificações (critérios de medição de um ângulo e tamanho dos optotipos, notações (decimal ou fracionárias, escalas (representando relações angulares, lineares, logarítmicas e unidades em que os valores são expressos (recíproca do minuto de arco, número puro, freqüência espacial, decibéis e oitavas. Como conseqüência, referências numéricas sobre a acuidade visual e operações que as envolvem (p.ex., cálculo de valores médios, determinação de variações, relações entre elas podem levar a interpretações muito diferentes e até opostas num mesmo estudo, dependendo dos critérios nele empregados.Evaluations of the visual function are very intricate since they depend on afferent, efferent and cognitive mechanisms, besides external factors of the examined subject, such as the type of the stimulus and of its presentation. Testing the visual acuity is discussed in its formal aspects related to definitions, quantifications (criteria for the measurements of an angle, size of optotypes, notations (decimal or fractionary, scales (representing angular, linear or logarithmic relationships and units in which the values are expressed (reciprocal of minutes of arc, pure number, spacial frequency, decibels, octaves. As a consequence, numerical references about visual acuity and respective operations (e.g., calculations of average values, determinations of variations, relationships between them may lead to very different interpretations of a study, sometimes even opposite, according to the criteria which are used.

  5. Bilateral foveal retinoschisis accompanying unilateral peripheral retinoschisis

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available X-linked juvenile retinoschisis is a rare hereditary retinal disease characterized by a tangential splitting of the neurosensory retina which may cause early-onset visual impairment. Existence of the retinal neurosensory layer splitting on cross-sectional images of optical coherance tomography (OCT and the absence of leakage on fluorescein angiography (FA help confirming the diagnosis. Such diagnostic tests are also helpful in determining the management of the disease. However, most of the retinoschisis cavities remain stable and rarely extend to the posterior pole, many authors suggest laser prophylaxis to avoid the potential risk of retinal detachment due to holes in the outer retinal layer. Herein, we report a case with bilateral foveal retinoschisis accompanying unilateral peripheral retinoschisis who was evaluated with detailed ophthalmologic examination. Visual acuity, fundoscopy, OCT, and FA remained stable in the second year of follow-up after prophylactic argon laser treatment.

  6. Origins of Superior Dynamic Visual Acuity in Baseball Players: Superior Eye Movements or Superior Image Processing

    OpenAIRE

    Uchida, Yusuke; Kudoh, Daisuke; Murakami, Akira; Honda, Masaaki; Kitazawa, Shigeru

    2012-01-01

    Dynamic visual acuity (DVA) is defined as the ability to discriminate the fine parts of a moving object. DVA is generally better in athletes than in non-athletes, and the better DVA of athletes has been attributed to a better ability to track moving objects. In the present study, we hypothesized that the better DVA of athletes is partly derived from better perception of moving images on the retina through some kind of perceptual learning. To test this hypothesis, we quantitatively measured DV...

  7. Effect of ruboxistaurin (RBX) On visual acuity decline over a 6-year period with cessation and reinstitution of therapy

    DEFF Research Database (Denmark)

    Sheetz, Matthew J; Aiello, Lloyd Paul; Shahri, Nazila

    2011-01-01

    reduced the occurrence of sustained moderate visual loss (SMVL; ≥15-letter decline in visual acuity sustained for the last 6 months of study participation) from 9.1% in the PBO group (N = 340) to 5.5% in the RBX group (N = 345, P = 0.034). This study evaluates the primary end point of SMVL in a 2-year...

  8. Comparison of monochromatic aberrations in young adults with different visual acuity and refractive errors.

    Science.gov (United States)

    Yazar, Seyhan; Hewitt, Alex W; Forward, Hannah; McKnight, Charlotte M; Tan, Alex; Mountain, Jenny A; Mackey, David A

    2014-03-01

    To compare the monochromatic aberrations in a large cohort of 20-year-old Australians with differing levels of visual acuity and explore the relationship between these aberrations and refractive error. Lions Eye Institute, Perth, Western Australia, Australia. Cross-sectional analysis of a population-based cohort. Monochromatic aberrations were measured using a Zywave II wavefront aberrometer with natural pupils in a dark room. The logMAR corrected distance visual acuity (CDVA) was measured monocularly under normal illumination. Cycloplegic autorefraction was also performed. The study enrolled 2039 eyes of 1040 participants. Data from 1007 right eyes were analyzed. The median CDVA and spherical equivalent were -0.06 logMAR (interquartile range [IQR], -0.10 to 0.00) and +0.25 diopters (D) (IQR, -0.38 to 0.63), respectively. The median 6.0 mm higher-order aberration (HOA) was 0.58 μm (IQR, 0.44 to 0.79). Coma-like aberrations and 3rd-, 4th-, and 5th-order HOAs were significantly different between subjects with a CDVA of -0.10 logMAR or better and those with a CDVA worse than -0.10 logMAR. Fourth-order aberrations Z(4,-4) (P=.024) and Z(4,-2) (P=.029) and 2nd-order aberration Z(2,0) (Peyes, emmetropic eyes, and hyperopic eyes. Subjects with higher myopia had slightly higher total HOAs. The HOAs in this population were marginally higher than previously reported values. The findings confirm there is a difference in monochromatic aberrations between different vision and refractive groups. Results in this study will benefit decision-making processes in the clinical setting. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Oxygen consumption remains stable while ammonia excretion is reduced upon short time exposure to high salinity in Macrobrachium acanthurus (Caridae: Palaemonidae, a recent freshwater colonizer

    Directory of Open Access Journals (Sweden)

    Carolina A. Freire

    2017-10-01

    Full Text Available ABSTRACT Palaemonid shrimps occur in the tropical and temperate regions of South America and the Indo-Pacific, in brackish/freshwater habitats, and marine coastal areas. They form a clade that recently (i.e., ~30 mya invaded freshwater, and one included genus, Macrobrachium Bate, 1868, is especially successful in limnic habitats. Adult Macrobrachium acanthurus (Wiegmann, 1836 dwell in coastal freshwaters, have diadromous habit, and need brackish water to develop. Thus, they are widely recognized as euryhaline. Here we test how this species responds to a short-term exposure to increased salinity. We hypothesized that abrupt exposure to high salinity would result in reduced gill ventilation/perfusion and decreased oxygen consumption. Shrimps were subjected to control (0 psu and experimental salinities (10, 20, 30 psu, for four and eight hours (n = 8 in each group. The water in the experimental containers was saturated with oxygen before the beginning of the experiment; aeration was interrupted before placing the shrimp in the experimental container. Dissolved oxygen (DO, ammonia concentration, and pH were measured from the aquaria water, at the start and end of each experiment. After exposure, the shrimp’s hemolymph was sampled for lactate and osmolality assays. Muscle tissue was sampled for hydration content (Muscle Water Content, MWC. Oxygen consumption was not reduced and hemolymph lactate did not increase with increased salinity. The pH of the water decreased with time, under all conditions. Ammonia excretion decreased with increased salinity. Hemolymph osmolality and MWC remained stable at 10 and 20 psu, but osmolality increased (~50% and MWC decreased (~4% at 30 psu. The expected reduction in oxygen consumption was not observed. This shrimp is able to tolerate significant changes in water salt concentrations for a few hours by keeping its metabolism in aerobic mode, and putatively shutting down branchial salt uptake to avoid massive salt

  10. Visual function after strontium-90 plaque irradiation in patients with age-related subfoveal choroidal neovascularization

    Energy Technology Data Exchange (ETDEWEB)

    Jaakkola, A.; Tarkkanen, A.; Immonen, I. [Helsinki Univ. Central Hospital, Dept. of Ophthalmology (Finland); Heikkonen, J. [Helsinki Univ. Central Hospital, Dept. of Oncology (Finland)

    1999-05-01

    Purpose: To report 2-year visual and angiographic results in eyes treated with strontium plaque irradiation for subfoveal choroidal neovascular membranes (CNVM) in age-related macular degeneration. Methods: Twenty eyes with recent subfoveal CNVM were treated with local irradiation. The impact of the treatment on visual function was evaluated by visual acuity, contrast sensitivity and reading speed testing. Results: At 12 months visual acuity had improved or remained the same in 9/20 eyes (45%). At 24 months visual acuity was stable in 5/18 eyes (28%). Eyes with signs of CNVM regression (13/18,72%) lost a mean of 3.3 lines, but eyes with recurrent CNVM lost a mean of 5.1 lines of vision. The mean contrast sensitivity was better in the irradiated eyes than in the fellow eyes with late age-related macular degeneration at 24 months. Six of 17 irradiated eyes (35%) could read at least some words at 24 months. Conclusion: Visual function decreases in patients treated with strontium irradiation, but less in eyes showing regression of the CNVM than in eyes with further growth of the CNVM. (au) 20 refs.

  11. CORRELATION OF CLINICAL AND STRUCTURAL PROGRESSION WITH VISUAL ACUITY LOSS IN MACULAR TELANGIECTASIA TYPE 2: MacTel Project Report No. 6-The MacTel Research Group.

    Science.gov (United States)

    Peto, Tunde; Heeren, Tjebo F C; Clemons, Traci E; Sallo, Ferenc B; Leung, Irene; Chew, Emily Y; Bird, Alan C

    2018-01-01

    To evaluate progression of macular telangiectasia Type 2 lesions and their correlation with visual acuity. An international multicenter prospective study with annual examinations including best-corrected visual acuity (BCVA), fundus photography, fluorescein angiography, and optical coherence tomography images graded centrally. Mixed models were used to estimate progression rates, and a generalized linear model to compute the relative risk of BCVA loss, loss of ellipsoid zone (EZ) reflectivity, development of pigment plaques, or neovascularization. One thousand and fourteen eyes of 507 participants were followed for 4.2 ± 1.6 years. Best-corrected visual acuity decreased 1.07 ± 0.05 letters (mean ± SE) per year. Of all eyes, 15% lost ≥15 letters after 5 years. Of the eyes without EZ loss, 76% developed a noncentral loss. Of the eyes with noncentral loss, 45% progressed to central EZ loss. The rate of BCVA loss in eyes with noncentral EZ loss at baseline was similar to eyes without EZ loss. The rate of BCVA loss was significantly higher in eyes with central EZ loss at baseline (-1.40 ± 0.14 letters, P structural component reflecting visual function. Its presence in the fovea significantly correlates with worse visual prognosis.

  12. Recovery of Visual Function in a Patient with an Onodi Cell Mucocele Compressive Optic Neuropathy Who Had a 5-Week Interval between Onset and Surgical Intervention: A Case Report

    Directory of Open Access Journals (Sweden)

    Wencan Wu

    2010-01-01

    Full Text Available Purpose. To report on a patient with compressive optic neuropathy secondary to an Onodi cell mucocele, who fully recovered visual function following surgery. Method. Case report. Results. A 28-year-old male was admitted with a right visual acuity of 20/100 following treatment for an initial diagnosis of optic neuritis. Subsequent examination suggested compressive optic neuropathy, and neuroimaging confirmed the presence of an Onodi mucocele compressing the optic nerve. The patient underwent a right endonasal sphenoethmoidectomy with decompression 5 weeks after the initial onset of symptoms. Three weeks following surgery, the visual acuity was 20/20, and there was complete resolution of the visual field defect, which has remained stable at 1 year. Conclusion. Onodi cell mucocele should be included in the differential diagnosis of a young patient with compressive optic neuropathy. Surgical decompression should be considered even when symptoms have been present for over a month.

  13. Heat-stable proteins and abscisic acid action in barley aleurone cells

    International Nuclear Information System (INIS)

    Jacobsen, J.V.; Shaw, D.C.

    1989-01-01

    [ 35 S]Methionine labeling experiments showed that abscisic acid (ABA) induced the synthesis of at least 25 polypeptides in mature barley (Hordeum vulgare) aleurone cells. The polypeptides were not secreted. Whereas most of the proteins extracted from aleurone cells were coagulated by heating to 100 degree C for 10 minutes, most of the ABA-induced polypeptides remained in solution (heat-stable). ABA had little effect on the spectrum of polypeptides that were synthesized and secreted by aleurone cells, and most of these secreted polypeptides were also heat-stable. Coomassie blue staining of sodium dodecyl sulfate polyacrylamide gels indicated that ABA-induced polypeptides already occurred in high amounts in mature aleurone layers having accumulated during grain development. About 60% of the total protein extracted from mature aleurone was heat stable. Amino acid analyses of total preparations of heat-stable and heat-labile proteins showed that, compared to heat-labile proteins, heat-stable intracellular proteins were characterized by higher glutamic acid/glutamine (Glx) and glycine levels and lower levels of neutral amino acids. Secreted heat-stable proteins were rich in Glx and proline. The possibilities that the accumulation of the heat-stable polypeptides during grain development is controlled by ABA and that the function of these polypeptides is related to their abundance and extraordinary heat stability are considered

  14. The role of visual acuity and segmentation cues in compound word identification

    Directory of Open Access Journals (Sweden)

    Jukka eHyönä

    2012-06-01

    Full Text Available Studies are reviewed that demonstrate how the foveal area of the eye constrains how compound words are identified during reading. When compound words are short, their letters can be identified during a single fixation, leading to the whole-word route dominating word recognition from early on. Hence, visually marking morpheme boundaries by hyphens slows down processing by encouraging morphological decomposition when holistic processing is a feasible option. In contrast, the decomposition route dominates the early stages of identifying long compound words. Thus, visual marking of morpheme boundaries facilitates processing of long compound words, unless the initial fixation made on the word lands very close to the morpheme boundary. The reviewed pattern of results is explained by the visual acuity principle (Bertram & Hyönä, 2003 and the dual-route framework of morphological processing.

  15. Endemism hotspots are linked to stable climatic refugia.

    Science.gov (United States)

    Harrison, Susan; Noss, Reed

    2017-01-01

    Centres of endemism have received much attention from evolutionists, biogeographers, ecologists and conservationists. Climatic stability is often cited as a major reason for the occurrences of these geographic concentrations of species which are not found anywhere else. The proposed linkage between endemism and climatic stability raises unanswered questions about the persistence of biodiversity during the present era of rapidly changing climate. The current status of evidence linking geographic centres of endemism to climatic stability over evolutionary time was examined. The following questions were asked. Do macroecological analyses support such an endemism-stability linkage? Do comparative studies find that endemic species display traits reflecting evolution in stable climates? Will centres of endemism in microrefugia or macrorefugia remain relatively stable and capable of supporting high biological diversity into the future? What are the implications of the endemism-stability linkage for conservation? Recent work using the concept of climate change velocity supports the classic idea that centres of endemism occur where past climatic fluctuations have been mild and where mountainous topography or favourable ocean currents contribute to creating refugia. Our knowledge of trait differences between narrow endemics and more widely distributed species remains highly incomplete. Current knowledge suggests that centres of endemism will remain relatively climatically buffered in the future, with the important caveat that absolute levels of climatic change and species losses in these regions may still be large. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Stable isotopes

    International Nuclear Information System (INIS)

    Evans, D.K.

    1986-01-01

    Seventy-five percent of the world's stable isotope supply comes from one producer, Oak Ridge Nuclear Laboratory (ORNL) in the US. Canadian concern is that foreign needs will be met only after domestic needs, thus creating a shortage of stable isotopes in Canada. This article describes the present situation in Canada (availability and cost) of stable isotopes, the isotope enrichment techniques, and related research programs at Chalk River Nuclear Laboratories (CRNL)

  17. Multifocal Choroiditis with Retinal Vasculitis, Optic Neuropathy, and Keratoconus in a Young Saudi Male.

    Science.gov (United States)

    Dhafiri, Yousef; Al Rubaie, Khalid; Kirat, Omar; May, William N; Nguyen, Quan D; Kozak, Igor

    2017-01-01

    The purpose of this study is to describe an association of unilateral multifocal choroiditis (MFC), retinal vasculitis, optic neuropathy, and bilateral keratoconus in a young Saudi male. A 27-year-old male patient with stable bilateral keratoconus presented with a painless vision loss in his left eye. Ophthalmic examinations revealed multiple foci of idiopathic chorioretinitis, retinal vasculitis, and mild optic disc leakage on fluorescein angiography, all of which resolved on systemic therapy with mycophenolate mofetil and prednisone after 3 months. Systemic medication was stopped after 8 months. One year after presentation, patient's visual acuity has improved and remained stable. Systemic immunomodulatory therapy can be effective in managing and leading to resolution of MFC, retinal vasculitis, and optic disc leak in young patients.

  18. Decline of tactile acuity in aging: a study of body site, blood flow, and lifetime habits of smoking and physical activity.

    Science.gov (United States)

    Stevens, Joseph C; Alvarez-Reeves, Marty; Dipietro, Loretta; Mack, Gary W; Green, Barry G

    2003-01-01

    Tactile acuity of 60 older subjects (> or = 65 years) and 19 younger subjects (18-28 years) was assessed by two-point gap thresholds at the upper and lower surfaces of the forefinger, at the upper and lower surfaces of the feet, and at the volar surface of the forearm. The older subjects were assigned to one of four groups of 15 subjects each, depending on reported lifetime habits of physical activity and smoking: (1) active smokers, (2) active nonsmokers, (3) inactive smokers, and (4) inactive nonsmokers. Peripheral blood flow was assessed at the forefinger, foot, and forearm by means of laser-Doppler imaging and skin temperature recordings, under resting conditions and during and after a 5-min exposure to mild cooling (28 degrees C). Consistent with previous studies, tactile acuity thresholds in the foot and finger averaged about 80% higher in the older subjects than in the younger subjects, but only about 22% higher in the forearm. Although the upper surface of the fingertip was more sensitive than the lower surface in both younger and older subjects, the age-related decline in tactile acuity was nearly identical on both sides of the finger and foot. The latter finding refutes the hypothesis that the larger effect of aging in the extremities results from greater physical wear and tear on the contact surfaces of the hands and feet. Self-reported lifetime histories of physical activity and smoking were not significantly associated with measures of cutaneous blood flow or tactile thresholds. Possible reasons for this lack of association are discussed, including the inherent limitations of testing only healthy older subjects, and the concept of "successful aging".

  19. Stable isotopic analysis of fossil chironomids as an approach to environmental reconstruction: state of development and future challenges

    Directory of Open Access Journals (Sweden)

    Oliver Heiri

    2012-10-01

    Full Text Available Remains of chironomid larvae, especially their strongly sclerotized head capsules, can be found abundantly and well preserved in most lake sediment records. These remains mainly consist of chitin and proteins and, since their chemical composition does not seem to be strongly affected by decompositional processes, they can be used to develop palaeoenvironmental reconstructions based on their stable isotopic composition. Here we review available stable isotope studies based on fossil chironomids and indicate future research necessary to further develop this still relatively new research approach. Efforts to produce stable isotope records based on fossil chironomids have mainly examined the elements H, N, C, and O. They have focussed on (1 developing the methodology for preparing samples for isotopic analysis, (2 laboratory studies cultivating chironomid larvae under controlled conditions to determine the factors affecting their stable isotopic composition, (3 ecosystem-scale studies relating stable isotopic measurements of fossil chironomid assemblages to environmental conditions, and (4 developing first down-core records describing past changes in the stable isotopic composition of chironomid assemblages. These studies have shown that chemical sample pretreatment may affect the isotopic composition for some elements. Laboratory runs suggest that the diet of the larvae influences their stable isotopic composition for H, N, C and O, whereas stable isotopes in the ambient water also strongly influence their oxygen and to a lesser extent hydrogen isotopic composition. These experiments also indicate only minor offsets between the nitrogen and carbon isotopic composition of chironomid soft tissue and the fossilizing head capsules, whereas for hydrogen and oxygen this offset remains to be explored. Though few datasets have been published, the available ecosystem studies and developed down-core sediment records indicate that stable isotopes in

  20. Mechanical Properties of Stable Glasses Using Nanoindentation

    Science.gov (United States)

    Wolf, Sarah; Liu, Tianyi; Jiang, Yijie; Ablajan, Keyume; Zhang, Yue; Walsh, Patrick; Turner, Kevin; Fakhraai, Zahra

    Glasses with enhanced stability over ordinary, liquid quenched glasses have been formed via the process of Physical Vapor Deposition (PVD) by using a sufficiently slow deposition rate and a substrate temperature slightly below the glass transition temperature. These stable glasses have been shown to exhibit higher density, lower enthalpy, and better kinetic stability over ordinary glass, and are typically optically birefringent, due to packing and orientational anisotropy. Given these exceptional properties, it is of interest to further investigate how the properties of stable glasses compare to those of ordinary glass. In particular, the mechanical properties of stable glasses remain relatively under-investigated. While the speed of sound and elastic moduli have been shown to increase with increased stability, little is known about their hardness and fracture toughness compared to ordinary glasses. In this study, glasses of 9-(3,5-di(naphthalen-1-yl)phenyl)anthracene were deposited at varying temperatures relative to their glass transition temperature, and their mechanical properties measured by nanoindentation. Hardness and elastic modulus of the glasses were compared across substrate temperatures. After indentation, the topography of these films were studied using Atomic Force Microscopy (AFM) in order to further compare the relationship between thermodynamic and kinetic stability and mechanical failure. Z.F. and P.W. acknowledge funding from NSF(DMREF-1628407).

  1. A pilot trial of the iPad tablet computer as a portable device for visual acuity testing.

    Science.gov (United States)

    Zhang, Zhao-tian; Zhang, Shao-chong; Huang, Xiong-gao; Liang, Ling-yi

    2013-01-01

    We evaluated the accuracy of an app for the iPad tablet computer (Eye Chart Pro) as a portable method of visual acuity (VA) testing. A total of 120 consecutive patients (240 eyes) underwent visual acuity test with an iPad 2 and a conventional light-box chart. The logMAR VA results from the iPad were significantly higher than those from the light-box (P iPad chart and the light-box chart, with 95% limits of agreement of -0.14 to 0.19. Two groups of patients were defined: in Group 1 there were 182 eyes with VA better than 0.1 according to the light-box VA test. The median logMAR VA by the iPad was 0.54 and by the light-box chart it was 0.52; there was no significant difference between them (P = 0.69). In Group 2 there were 58 eyes with VA equal to or worse than 0.1 according to the light-box VA test. The median logMAR VA by the iPad was 1.26 and was 1.10 by the light box; the result from the iPad was significantly lower (P iPad is reliable for VA testing only when the Snellen VA is better than 0.1 (20/200).

  2. Stable Isotope Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Tissue samples (skin, bone, blood, muscle) are analyzed for stable carbon, stable nitrogen, and stable sulfur analysis. Many samples are used in their entirety for...

  3. stableGP

    Data.gov (United States)

    National Aeronautics and Space Administration — The code in the stableGP package implements Gaussian process calculations using efficient and numerically stable algorithms. Description of the algorithms is in the...

  4. Immunosuppression Adherence in Stable Kidney Transplant Patients Converted From Immediate- to Prolonged-Release Tacrolimus in Clinical Practice: A Norwegian Study

    Directory of Open Access Journals (Sweden)

    Sadollah Abedini, MD, PhD

    2018-02-01

    Conclusions. There was disparity between high, patient-perceived and low, actual adherence. Converting stable KTPs from IR-T to PR-T in routine practice did not impact long-term adherence to immunosuppression; renal function remained stable.

  5. The Advanced Glaucoma Intervention Study (AGIS): 12. Baseline risk factors for sustained loss of visual field and visual acuity in patients with advanced glaucoma.

    Science.gov (United States)

    2002-10-01

    To examine the relationships between baseline risk factors and sustained decrease of visual field (SDVF) and sustained decrease of visual acuity (SDVA). Cohort study of participants in the Advanced Glaucoma Intervention Study (AGIS). This multicenter study enrolled patients between 1988 and 1992 and followed them until 2001; 789 eyes of 591 patients with advanced glaucoma were randomly assigned to one of two surgical sequences, argon laser trabeculoplasty (ALT)-trabeculectomy-trabeculectomy (ATT) or trabeculectomy-ALT-trabeculectomy (TAT). This report is based on data from 747 eyes. Eyes were offered the next intervention in the sequence upon failure of the previous intervention. Failure was based on recurrent intraocular pressure elevation, visual field defect, and disk rim criteria. Study visits occurred every 6 months; potential follow-up ranged from 8 to 13 years. For each intervention sequence, Cox multiple regression analyses were used to examine the baseline characteristics for association with two vision outcomes: SDVF and SDVA. The magnitude of the association is measured by the hazard ratio (HR), where HR for binary variables is the relative change in the hazard (or risk) of the outcome in eyes with the factor divided by the hazard in eyes without the factor, and HR for continuous variables is the relative change in the hazard (or risk) of the outcome in eyes with a unit increase in the factor. Characteristics associated with increased SDVF risk in the ATT sequence are: less baseline visual field defect (hazard ratio [HR] = 0.86, P <.001, 95% CI = 0.82-0.90), male gender (HR = 2.23, P <.001, 1.54-3.23), and worse baseline visual acuity (HR = 0.96, P =.001, 0.94-0.98); in the TAT sequence: less baseline visual field defect (HR = 0.93, P =.001, 0.89-0.97) and diabetes (HR = 1.87, P =.007, 1.18-2.97). Characteristics associated with increased SDVA risk in both treatment sequences are better baseline acuity (ATT: HR = 1.05, P <.001, 1.02-1.09; TAT: HR = 1

  6. Accuracy of ‘My Gut Feeling:’ Comparing System 1 to System 2 Decision-Making for Acuity Prediction, Disposition and Diagnosis in an Academic Emergency Department

    Directory of Open Access Journals (Sweden)

    Daniel Cabrera

    2015-10-01

    Full Text Available Introduction: Current cognitive sciences describe decision-making using the dual-process theory, where a System 1 is intuitive and a System 2 decision is hypothetico-deductive. We aim to compare the performance of these systems in determining patient acuity, disposition and diagnosis. Methods: Prospective observational study of emergency physicians assessing patients in the emergency department of an academic center. Physicians were provided the patient’s chief complaint and vital signs and allowed to observe the patient briefly. They were then asked to predict acuity, final disposition (home, intensive care unit (ICU, non-ICU bed and diagnosis. A patient was classified as sick by the investigators using previously published objective criteria. Results: We obtained 662 observations from 289 patients. For acuity, the observers had a sensitivity of 73.9% (95% CI [67.7-79.5%], specificity 83.3% (95% CI [79.5-86.7%], positive predictive value 70.3% (95% CI [64.1-75.9%] and negative predictive value 85.7% (95% CI [82.0-88.9%]. For final disposition, the observers made a correct prediction in 80.8% (95% CI [76.1-85.0%] of the cases. For ICU admission, emergency physicians had a sensitivity of 33.9% (95% CI [22.1-47.4%] and a specificity of 96.9% (95% CI [94.0-98.7%]. The correct diagnosis was made 54% of the time with the limited data available. Conclusion: System 1 decision-making based on limited information had a sensitivity close to 80% for acuity and disposition prediction, but the performance was lower for predicting ICU admission and diagnosis. System 1 decision-making appears insufficient for final decisions in these domains but likely provides a cognitive framework for System 2 decision-making.

  7. Stable isotope geochemistry : definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2014-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeoclimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology, and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. These applications can be broadly classified into four main types: 1. Thermometry: Formation temperatures of rock and mineral systems are determined on the basis of temperature-dependent fractionations of the isotopic ratios between two or more cogenetic phases. 2. Tracers: Reservoirs like the ocean, the mantle, meteoric waters and organic matter have distinct stable isotope signatures that can be used to trace the origin of rocks, fluids, contaminants etc. 3. Reaction mechanism: Distinctions can be made between diffusion and recrystallization, open and closed systems and bacterial and thermogenic processes. 4. Chemostratigraphy: Abrupt changes (excursions) in the stable isotope ratios of ocean sediments and certain terrestrial materials can be used as stratigraphic markers. (author)

  8. Stable isotope geochemistry: definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2015-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeoclimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology, and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. These applications can be broadly classified into four main types: 1. Thermometry: Formation temperatures of rock and mineral systems are determined on the basis of temperature-dependent fractionations of the isotopic ratios between two or more cogenetic phases. 2. Tracers: Reservoirs like the ocean, the mantle, meteoric waters and organic matter have distinct stable isotope signatures that can be used to trace the origin of rocks, fluids, contaminants etc. 3. Reaction mechanism: Distinctions can be made between diffusion and recrystallization, open and closed systems and bacterial and thermogenic processes. 4. Chemostratigraphy: Abrupt changes (excursions) in the stable isotope ratios of ocean sediments and certain terrestrial materials can be used as stratigraphic markers. (author).

  9. Stable isotope geochemistry : definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2016-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeoclimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology, and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. These applications can be broadly classified into four main types: 1. Thermometry: Formation temperatures of rock and mineral systems are determined on the basis of temperature-dependent fractionations of the isotopic ratios between two or more cogenetic phases. 2. Tracers: Reservoirs like the ocean, the mantle, meteoric waters and organic matter have distinct stable isotope signatures that can be used to trace the origin of rocks, fluids, contaminants etc. 3. Reaction mechanism: Distinctions can be made between diffusion and recrystallization, open and closed systems and bacterial and thermogenic processes. 4. Chemostratigraphy: Abrupt changes (excursions) in the stable isotope ratios of ocean sediments and certain terrestrial materials can be used as stratigraphic markers. (author).

  10. Perception of Komfo Anokye Teaching Hospital Emergency Centre staff on acuity of patients” presentation and appropriateness of attendance

    Directory of Open Access Journals (Sweden)

    P.K. Forson

    2013-06-01

    Discussion: Staff in this study were not unanimous on the acuity of presentation of walk-in patients and referred patients. Walk-in patients were more likely turned away from the EC. Though perception of staff may hold inherent weakness of objectiveness, this may inform staff attitudes to care for walk-in patients. Negative perceptions of staff on overcrowding in EC could be addressed through staff training and policy directed at reducing EC overcrowding.

  11. Acuidade visual em implantes bilaterais de lentes intra-oculares monofocais e multifocais Visual acuity of bilateral implants of monofocal and multifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2003-01-01

    Full Text Available OBJETIVO: Comparar a acuidade visual de longe e perto de pacientes submetidos à facoemulsificação binocular não simultânea com implante de lentes multifocais ou monofocais. MÉTODOS: Foram selecionados 20 pacientes com lentes multifocais bilaterais e outros 20 pacientes com lentes monofocais também bilaterais, com acuidade visual sem correção melhor ou igual a 0,63 (20/30, medidos separadamente, nos três primeiros meses de pós-operatório. Foi medida a acuidade visual para longe e perto com e sem correção e testes de sensibilidade ao contraste e ofuscamento. RESULTADOS: A acuidade visual sem correção para longe no grupo das monofocais teve média de 0,82 (DP± 0,16 e no grupo das multifocais, 0,94 (DP±0,12, valor de p 0,001. Os dois grupos de lentes tiveram visão com correção para longe igual a 1. No grupo das multifocais, 75% tiveram J1 e 100% tiveram J3 ou melhor sem correção. No grupo das lentes monofocais, 10% tiveram J1 e 70% tiveram J3 ou melhor sem correção. Não houve diferença significante na avaliação com o teste de sensibilidade ao contraste entre os grupos pesquisados. No teste de ofuscamento, os dois grupos tiveram redução da visão, que foi mais acentuada no grupo dos pacientes com lentes multifocais. CONCLUSÃO: A acuidade visual para longe com correção nos pacientes com implante multifocal foi semelhante a dos pacientes com implantes monofocais, embora a acuidade visual para perto no grupo em que foi implantado lente multifocal foi bastante superior ao grupo da lente monofocal. A sensibilidade ao contraste manteve-se semelhante nos dois grupos, já o ofuscamento ("glare test" no grupo multifocal foi maior que no grupo monofocal.PURPOSE: To compare distant and near visual acuity between patients submitted to bilateral nonsimultaneous facoemulsification and implantation of multifocal or monofocal intraocular lenses (IOL. METHODS: Twenty patients with bilateral multifocal IOL and 20 patients with

  12. Stereotaxic pituitary implantation of radio-gold in the treatment of severe diabetic retinopathy. Long term results

    International Nuclear Information System (INIS)

    Mirouze, J.; Schmouker, Y.; Cartry, E.

    1980-01-01

    The ophtalmic, diabetic and hormonal outcome in 16 patients treated identically for diabetic ophtalmopathy with pituitary radio-gold implants were assessed 1, 2, 5 and 10 years afterwards. Four patients (25%) died in the first 6 years, 3 of them of severe renal insufficiency which developed after pituitary implantation. Of these remaining alive at each assessment visual acuity was either stable or improved in 78%, 58%, 64% and 42% respectively, but at very low levels since at 10 years acuity was 1/10 or less in half the population. Four patients became blind, the remaining eight had a severe proliferative retinopathy with exsudates and haemorrhages but retained useful vision. Haemorrhage and new vessel formation continued to develop with the years following implantation in all patients who at the time had one on either lesion. Cataracts were removed in 6 patients, 3 and 7 years after implantation. The mean insulin requirements of the group fall from 55 to 31 units daily. The fall in groth hormone concentration, occuring in only 45% of cases, does not account for all the improvements observed. Several hormonal deficiencies developed: 2 cases of adrenal insufficiency, 3 of hypothyroidism and 6 of hypogonadal impotence [fr

  13. Stereotaxic pituitary implantation of radio-gold in the treatment of severe diabetic retinopathy. Long term results

    Energy Technology Data Exchange (ETDEWEB)

    Mirouze, J; Schmouker, Y; Cartry, E [Hopital Saint-Eloi, 34 - Montpellier (France)

    1980-03-01

    The ophtalmic, diabetic and hormonal outcome in 16 patients treated identically for diabetic ophtalmopathy with pituitary radio-gold implants were assessed 1, 2, 5 and 10 years afterwards. Four patients (25%) died in the first 6 years, 3 of them of severe renal insufficiency which developed after pituitary implantation. Of these remaining alive at each assessment visual acuity was either stable or improved in 78%, 58%, 64% and 42% respectively, but at very low levels since at 10 years acuity was 1/10 or less in half the population. Four patients became blind, the remaining eight had a severe proliferative retinopathy with exsudates and haemorrhages but retained useful vision. Haemorrhage and new vessel formation continued to develop with the years following implantation in all patients who at the time had one on either lesion. Cataracts were removed in 6 patients, 3 and 7 years after implantation. The mean insulin requirements of the group fall from 55 to 31 units daily. The fall in growth hormone concentration, occuring in only 45% of cases, does not account for all the improvements observed. Several hormonal deficiencies developed: 2 cases of adrenal insufficiency, 3 of hypothyroidism and 6 of hypogonadal impotence.

  14. Silicon photonics: some remaining challenges

    Science.gov (United States)

    Reed, G. T.; Topley, R.; Khokhar, A. Z.; Thompson, D. J.; Stanković, S.; Reynolds, S.; Chen, X.; Soper, N.; Mitchell, C. J.; Hu, Y.; Shen, L.; Martinez-Jimenez, G.; Healy, N.; Mailis, S.; Peacock, A. C.; Nedeljkovic, M.; Gardes, F. Y.; Soler Penades, J.; Alonso-Ramos, C.; Ortega-Monux, A.; Wanguemert-Perez, G.; Molina-Fernandez, I.; Cheben, P.; Mashanovich, G. Z.

    2016-03-01

    This paper discusses some of the remaining challenges for silicon photonics, and how we at Southampton University have approached some of them. Despite phenomenal advances in the field of Silicon Photonics, there are a number of areas that still require development. For short to medium reach applications, there is a need to improve the power consumption of photonic circuits such that inter-chip, and perhaps intra-chip applications are viable. This means that yet smaller devices are required as well as thermally stable devices, and multiple wavelength channels. In turn this demands smaller, more efficient modulators, athermal circuits, and improved wavelength division multiplexers. The debate continues as to whether on-chip lasers are necessary for all applications, but an efficient low cost laser would benefit many applications. Multi-layer photonics offers the possibility of increasing the complexity and effectiveness of a given area of chip real estate, but it is a demanding challenge. Low cost packaging (in particular, passive alignment of fibre to waveguide), and effective wafer scale testing strategies, are also essential for mass market applications. Whilst solutions to these challenges would enhance most applications, a derivative technology is emerging, that of Mid Infra-Red (MIR) silicon photonics. This field will build on existing developments, but will require key enhancements to facilitate functionality at longer wavelengths. In common with mainstream silicon photonics, significant developments have been made, but there is still much left to do. Here we summarise some of our recent work towards wafer scale testing, passive alignment, multiplexing, and MIR silicon photonics technology.

  15. Visual acuity and refraction by age for children of three different ethnic groups in Paraguay

    Directory of Open Access Journals (Sweden)

    Marissa Janine Carter

    2013-04-01

    Full Text Available PURPOSE: To characterize refractive errors in Paraguayan children aged 5-16 years and investigate effect of age, gender, and ethnicity. METHODS:The study was conducted at 3 schools that catered to Mennonite, indigenous, and mixed race children. Children were examined for presenting visual acuity, autorefraction with and without cycloplegia, and retinoscopy. Data were analyzed for myopia and hyperopia (SE ≤-1 D or -0.5 D and ≥2 D or ≥3 D and astigmatism (cylinder ≥1 D. Spherical equivalent (SE values were calculated from right eye cycloplegic autorefraction data and analyzed using general linear modelling. RESULTS: There were 190, 118, and 168 children of Mennonite, indigenous and mixed race ethnicity, respectively. SE values between right/left eyes were nonsignificant. Mean visual acuity (VA without correction was better for Mennonites compared to indigenous or mixed race children (right eyes: 0.031, 0.090, and 0.102 logMAR units, respectively; P<0.000001. There were 2 cases of myopia in the Mennonite group (1.2% and 2 cases in the mixed race group (1.4% (SE ≤-0.5 D. The prevalence of hyperopia (SE ≥2 D was 40.6%, 34.2%, and 46.3% for Mennonite, indigenous and mixed race children. Corresponding astigmatism rates were 3.2%, 9.5%, and 12.7%. Females were slightly more hyperopic than males, and the 9-11 years age group was the most hyperopic. Mennonite and mixed race children were more hyperopic than indigenous children. CONCLUSIONS: Paraguayan children were remarkably hyperopic and relatively free of myopia. Differences with regard to gender, age, and ethnicity were small.

  16. [Management of post-traumatic aphakia and aniridia: Retrospective study of 17 patients undergoing scleral-sutured artificial iris intraocular lens implantation. Management of aphakia-aniridia with scleral-sutured artificial iris intraocular lenses].

    Science.gov (United States)

    Villemont, A-S; Kocaba, V; Janin-Manificat, H; Abouaf, L; Poli, M; Marty, A-S; Rabilloud, M; Fleury, J; Burillon, C

    2017-09-01

    To evaluate the long-term outcomes of artificial iris intraocular lenses sutured to the sclera for managing traumatic aphakia and aniridia. All consecutive cases receiving a Morcher ® combination implant from June 2008 to February 2016 in Edouard-Herriot Hospital (Lyon, France) were included in this single-center retrospective study. Visual acuity, subjective degree of glare, quality of life and surgical complications were evaluated. Seventeen eyes of 17 patients were included, among which 82% were male. The mean age was 42 years. The injuries consisted of 23.5% contusion and 70.5% open globe injuries, of which 41% were globe ruptures. There was one postoperative case. A penetrating keratoplasty was performed at the same time for eight eyes. The mean follow-up was 32 months. Best-corrected visual acuity improved in 41.2%, remained the same in 17.6% and decreased in 41.2% of our cases. Distance vision averaged 1±0.25 line better and near vision 2.2±0.32 lines better when visual acuity was quantifiable before surgery. Glare improved in 80% of patients and remained stable in 20%, decreasing on average from 3.3/5 [min. 3-max. 4; SD: 0.48] before surgery to 1.9/5 [min. 0-max. 4; SD: 1.197] after surgery. Regarding the esthetic results, 78% of the patients declared themselves reasonably to very satisfied; 57% reported no limitation of activities of daily living, and 43% reported mild limitation. Ocular hypertension and glaucoma, found in 40% of eyes, were the main postoperative complications. Implantation of prosthetic iris device combined with an intraocular lens appears to be safe and effective in reducing glare disability and improving visual acuity. Close, long-term monitoring is essential for the success of this surgery. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Stereoselective synthesis of stable-isotope-labeled amino acids

    Energy Technology Data Exchange (ETDEWEB)

    Unkefer, C.J.; Martinez, R.A.; Silks, L.A. III [Los Alamos National Laboratory, NM (United States); Lodwig, S.N. [Centralia College, WA (United States)

    1994-12-01

    For magnetic resonance and vibrational spectroscopies to reach their full potential, they must be used in combination with sophisticated site-specific stable isotope labeling of biological macromolecules. Labeled amino acids are required for the study of the structure and function of enzymes and proteins. Because there are 20 common amino acids, each with its own distinguishing chemistry, they remain a synthetic challenge. The Oppolzer chiral auxiliary provides a general tool with which to approach the synthesis of labeled amino acids. By using the Oppolzer auxiliary, amino acids can be constructed from several small molecules, which is ideal for stable isotope labeling. In addition to directing the stereochemistry at the {alpha}-carbon, the camphorsultam can be used for stereo-specific isotope labeling at prochiral centers in amino acids. By using the camphorsultam auxiliary we have the potential to synthesize virtually any isotopomer of all of the common amino acids.

  18. Stereoselective synthesis of stable-isotope-labeled amino acids

    International Nuclear Information System (INIS)

    Unkefer, C.J.; Martinez, R.A.; Silks, L.A. III; Lodwig, S.N.

    1994-01-01

    For magnetic resonance and vibrational spectroscopies to reach their full potential, they must be used in combination with sophisticated site-specific stable isotope labeling of biological macromolecules. Labeled amino acids are required for the study of the structure and function of enzymes and proteins. Because there are 20 common amino acids, each with its own distinguishing chemistry, they remain a synthetic challenge. The Oppolzer chiral auxiliary provides a general tool with which to approach the synthesis of labeled amino acids. By using the Oppolzer auxiliary, amino acids can be constructed from several small molecules, which is ideal for stable isotope labeling. In addition to directing the stereochemistry at the α-carbon, the camphorsultam can be used for stereo-specific isotope labeling at prochiral centers in amino acids. By using the camphorsultam auxiliary we have the potential to synthesize virtually any isotopomer of all of the common amino acids

  19. Parafoveal magnification: visual acuity does not modulate the perceptual span in reading.

    Science.gov (United States)

    Miellet, Sébastien; O'Donnell, Patrick J; Sereno, Sara C

    2009-06-01

    Models of eye guidance in reading rely on the concept of the perceptual span-the amount of information perceived during a single eye fixation, which is considered to be a consequence of visual and attentional constraints. To directly investigate attentional mechanisms underlying the perceptual span, we implemented a new reading paradigm-parafoveal magnification (PM)-that compensates for how visual acuity drops off as a function of retinal eccentricity. On each fixation and in real time, parafoveal text is magnified to equalize its perceptual impact with that of concurrent foveal text. Experiment 1 demonstrated that PM does not increase the amount of text that is processed, supporting an attentional-based account of eye movements in reading. Experiment 2 explored a contentious issue that differentiates competing models of eye movement control and showed that, even when parafoveal information is enlarged, visual attention in reading is allocated in a serial fashion from word to word.

  20. Stable isotope geochemistry : definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2009-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeolimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology, and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. These applications can be broadly classified into four main types: 1. Thermometry: Formation temperatures of rock and mineral systems are determined on the basis of temperature-dependent fractionations of the isotopic ratios between two or more cogenetic phases. 2. Tracers: Reservoirs like the ocean, the mantle, meteroic waters and organic matter have distinct stable isotope signatures that can be used to trace the origin of rocks, fluids, contaminants etc. 3. Reaction mechanism: Distinctions can be made between diffusion and recrystallization, open and closed systems and bacterial and thermogenic processes. 4. Chemostratigraphy: Abrupt changes (excursions) in the stable isotope ratios of ocean sediments and certain terrestrial materials can be used as stratigraphic markers. (author). 56 refs., 11 figs., 2 tabs.

  1. Stable isotope geochemistry : definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2012-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeoclimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology, and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. These applications can be broadly classified into four main types: 1. Thermometry: Formation temperatures of rock and mineral systems are determined on the basis of temperature-dependent fractionations of the isotopic ratios between two or more cogenetic phases. 2. Tracers: Reservoirs like the ocean, the mantle, meteoric waters and organic matter have distinct stable isotope signatures that can be used to trace the origin of rocks, fluids, contaminants etc. 3. Reaction mechanism: Distinctions can be made between diffusion and recrystallization, open and closed systems and bacterial and thermogenic processes. 4. Chemostratigraphy: Abrupt changes (excursions) in the stable isotope ratios of ocean sediments and certain terrestrial materials can be used as stratigraphic markers. (author). 89 refs., 12 figs., 2 tabs.

  2. Stable isotope geochemistry : definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2008-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeolimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology, and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. These applications can be broadly classified into four main types: 1. Thermometry: Formation temperatures of rock and mineral systems are determined on the basis of temperature-dependent fractionations of the isotopic ratios between two or more cogenetic phases. 2. Tracers: Reservoirs like the ocean, the mantle, meteroic waters and organic matter have distinct stable isotope signatures that can be used to trace the origin of rocks, fluids, contaminants etc. 3. Reaction mechanism: Distinctions can be made between diffusion and recrystallization, open and closed systems and bacterial and thermogenic processes. 4. Chemostratigraphy: Abrupt changes (excursions) in the stable isotope ratios of ocean sediments and certain terrestrial materials can be used as stratigraphic markers. (author). 56 refs., 11 figs., 2 tabs

  3. Stable isotope geochemistry : definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2009-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeolimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology, and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. These applications can be broadly classified into four main types: 1. Thermometry: Formation temperatures of rock and mineral systems are determined on the basis of temperature-dependent fractionations of the isotopic ratios between two or more cogenetic phases. 2. Tracers: Reservoirs like the ocean, the mantle, meteroic waters and organic matter have distinct stable isotope signatures that can be used to trace the origin of rocks, fluids, contaminants etc. 3. Reaction mechanism: Distinctions can be made between diffusion and recrystallization, open and closed systems and bacterial and thermogenic processes. 4. Chemostratigraphy: Abrupt changes (excursions) in the stable isotope ratios of ocean sediments and certain terrestrial materials can be used as stratigraphic markers. (author). 56 refs., 11 figs., 2 tabs

  4. Stable isotope geochemistry : definitions, terminology, measurement and some applications

    International Nuclear Information System (INIS)

    Faure, K.

    2013-01-01

    In 1936, Alfred Nier produced the first precise measurement of isotope abundance ratios and his design still remains the basis of stable isotope mass spectrometry. With this gift from the physicists for routine measurement of isotope ratios, earth scientists began to explore the natural variations of isotopes. Thus began a new era in geoscience research with the hydrological cycle and marine palaeoclimatic research being the first topics to be investigated. Stable isotope measurements have been applied to many fundamental problems in geochemistry, petrology, and paleoclimatology, as well as related fields in archaeology, anthropology, physical chemistry, biology and forensic sciences. These applications can be broadly classified into four main types: 1. Thermometry: Formation temperatures of rock and mineral systems are determined on the basis of temperature-dependent fractionations of the isotopic ratios between two or more cogenetic phases. 2. Tracers: Reservoirs like the ocean, the mantle, meteoric waters and organic matter have distinct stable isotope signatures that can be used to trace the origin of rocks, fluids, contaminants etc. 3. Reaction mechanism: Distinctions can be made between diffusion and recrystallization, open and closed systems and bacterial and thermogenic processes. 4. Chemostratigraphy: Abrupt changes (excursions) in the stable isotope ratios of ocean sediments and certain terrestrial materials can be used as stratigraphic markers. (author). 91 refs., 12 figs., 2 tabs.

  5. Correlation of visual acuity and central macular morphology in different types of diabetic macular edema

    Directory of Open Access Journals (Sweden)

    Qiu-Ju Wu

    2016-02-01

    Full Text Available AIM:To observe the correlation of visual acuity and central macular morphology in patients with different types of diabetic macular edema(DME. METHODS: Presented study was single-center, uncontrolled retrospective clinical study. Sixty-two patients(103 eyeswith DME were included. Best corrected visual acuity(BCVAwas evaluated using early treatment diabetic retinopathy study(ETDRSvision test chart. All patients were examined by non-contact tonometer, slit lamp, indirect ophthalmoscope, and fundus fluorescein angiography(FFA. Central subfield mean thickness(CSMTin the macular area of diameter 1mm was measured by optical coherence tomography(OCT.And in the same time the integrity of inner segments/ outer segments(IS/OSand external limiting membrane(ELMreflecting light strip of 350μm center horizontal scanning line was investigated by OCT. BCVA and CSMT in different types of DME patients were analyzed using Kruskal- Wallis test. BCVA and CSMT between the two-two groups in different types of DME patients were analyzed using Nemenyi test, and multiple regression analysis was used to analyze the relative factors of BCVA. RESULTS: In the 103 eyes, 47 eyes(45.6%were focal DME, 35 eyes(34.0%were diffuse DME, 6 eyes(5.8%were ischemic DME and 15 eyes(14.6%were proliferative DME. The difference of mean BCVA(H=69.167, PH=57.113, Pχ2=14.982,Pχ2=14.537,Pχ2=15.596,Pχ2=15.393,Pχ2=16.567,Pχ2=15.687,Pχ2=12.974、P=0.008; CSMT:χ2=13.999,Pr=-0.064,-0.207,-0.082 and -0.160, respectively, Pr=-0.885, -2.522, -1.504, and-0.595, respectively, P>0.05. CONCLUSION: There are statistically significant differences on macular morphology and vision function among different types of DME patients.

  6. Remaining useful life assessment of lithium-ion batteries in implantable medical devices

    Science.gov (United States)

    Hu, Chao; Ye, Hui; Jain, Gaurav; Schmidt, Craig

    2018-01-01

    This paper presents a prognostic study on lithium-ion batteries in implantable medical devices, in which a hybrid data-driven/model-based method is employed for remaining useful life assessment. The method is developed on and evaluated against data from two sets of lithium-ion prismatic cells used in implantable applications exhibiting distinct fade performance: 1) eight cells from Medtronic, PLC whose rates of capacity fade appear to be stable and gradually decrease over a 10-year test duration; and 2) eight cells from Manufacturer X whose rates appear to be greater and show sharp increase after some period over a 1.8-year test duration. The hybrid method enables online prediction of remaining useful life for predictive maintenance/control. It consists of two modules: 1) a sparse Bayesian learning module (data-driven) for inferring capacity from charge-related features; and 2) a recursive Bayesian filtering module (model-based) for updating empirical capacity fade models and predicting remaining useful life. A generic particle filter is adopted to implement recursive Bayesian filtering for the cells from the first set, whose capacity fade behavior can be represented by a single fade model; a multiple model particle filter with fixed-lag smoothing is proposed for the cells from the second data set, whose capacity fade behavior switches between multiple fade models.

  7. Subluxation of iris-sutured intraocular lenses and results of a closed chamber technique for repositioning after penetrating keratoplasty.

    Science.gov (United States)

    Jabbur, Nada S; Akpek, Esen Karamursel; Stark, Walter J

    2005-05-01

    To describe subluxation of iris-fixated intraocular lenses (IOLs) after penetrating keratoplasty (PK) as a postoperative complication and report the long-term outcomes of a closed-chamber refixation technique used in the management. This was a retrospective, noncomparative interventional case series in which 19 consecutive patient charts with a subluxated iris-fixated IOL after PK were retrospectively reviewed. Fourteen of the patients underwent surgery using a closed-chamber refixation technique. These patients were evaluated for visual outcome and surgical complications associated with the procedure. In 13 patients, postoperative follow-up was available. In all 13 cases, the fixated IOL appeared stable and remained well positioned during a follow-up period of 56 months (range, 6-122). All patients (100%) achieved improved uncorrected visual acuity. The postoperative visual acuity ranged from 20/20 to 20/100 with a mean of 20/40. Vitreous hemorrhage occurred in 1 patient, and an additional patient required a second surgery using the same technique. Both of these patients did well with a final visual acuity of 20/40 and 20/50, respectively. Subluxation of iris-fixated IOL after PK can occur as a postoperative complication. The technique that we herein describe enables secure refixation of subluxated IOLs and yields favorable long-term results.

  8. Spontaneous Resolution of Long-Standing Macular Detachment due to Optic Disc Pit with Significant Visual Improvement.

    Science.gov (United States)

    Parikakis, Efstratios A; Chatziralli, Irini P; Peponis, Vasileios G; Karagiannis, Dimitrios; Stratos, Aimilianos; Tsiotra, Vasileia A; Mitropoulos, Panagiotis G

    2014-01-01

    To report a case of spontaneous resolution of a long-standing serous macular detachment associated with an optic disc pit, leading to significant visual improvement. A 63-year-old female presented with a 6-month history of blurred vision and micropsia in her left eye. Her best-corrected visual acuity was 6/24 in the left eye, and fundoscopy revealed serous macular detachment associated with optic disc pit, which was confirmed by optical coherence tomography (OCT). The patient was offered vitrectomy as a treatment alternative, but she preferred to be reviewed conservatively. Three years after initial presentation, neither macular detachment nor subretinal fluid was evident in OCT, while the inner segment/outer segment (IS/OS) junction line was intact. Her visual acuity was improved from 6/24 to 6/12 in her left eye, remaining stable at the 6-month follow-up after resolution. We present a case of spontaneous resolution of a long-standing macular detachment associated with an optic disc pit with significant visual improvement, postulating that the integrity of the IS/OS junction line may be a prognostic factor for final visual acuity and suggesting OCT as an indicator of visual prognosis and the probable necessity of a surgical management.

  9. Spontaneous Resolution ofLong-Standing Macular Detachment due to Optic Disc Pit with Significant Visual Improvement

    Directory of Open Access Journals (Sweden)

    Efstratios A. Parikakis

    2014-03-01

    Full Text Available Purpose: To report a case of spontaneous resolution of a long-standing serous macular detachment associated with an optic disc pit, leading to significant visual improvement. Case Presentation: A 63-year-old female presented with a 6-month history of blurred vision and micropsia in her left eye. Her best-corrected visual acuity was 6/24 in the left eye, and fundoscopy revealed serous macular detachment associated with optic disc pit, which was confirmed by optical coherence tomography (OCT. The patient was offered vitrectomy as a treatment alternative, but she preferred to be reviewed conservatively. Three years after initial presentation, neither macular detachment nor subretinal fluid was evident in OCT, while the inner segment/outer segment (IS/OS junction line was intact. Her visual acuity was improved from 6/24 to 6/12 in her left eye, remaining stable at the 6-month follow-up after resolution. Conclusion: We present a case of spontaneous resolution of a long-standing macular detachment associated with an optic disc pit with significant visual improvement, postulating that the integrity of the IS/OS junction line may be a prognostic factor for final visual acuity and suggesting OCT as an indicator of visual prognosis and the probable necessity of a surgical management.

  10. Habitual plate-waste of 6- to 9-year-olds may not be associated with lower nutritional needs or taste acuity, but undesirable dietary factors.

    Science.gov (United States)

    Baik, Ji-Yoon; Lee, Hongmie

    2009-12-01

    Efforts to reduce plate-waste (PW) are limited to those by a dietitian who serves the entire school rather than a better characterization of individuals who are served. We tested the hypothesis that children reporting habitual PW would have different physical or dietary characteristics compared with children without PW. Participants were 407 children aged 6 to 9 years in elementary schools in Kyeonggi, Korea. Information on eating behavior and food preference was collected using a questionnaire administered by parents. Among them, 91 students participated further in anthropometry, step counting, taste acuity tests, and nutrition intake from school lunches. Participants were divided into tertiles according to total frequency of leaving PW from each meal on a typical day: no PW, moderate PW, and habitual PW. Children with habitual PW showed several undesirable characteristics: consuming less of various vegetables, eating only what they like, poor table manners, and frequent consumption of street foods and cookies/beverages/fast foods. Whereas height, weight, and obesity index as well as taste acuity and daily steps in the habitual PW group were not significantly different, intakes of potassium, niacin, and folate were significantly lower compared with the other groups. Therefore, habitual PW did not seem to result from having a lower energy requirement or different taste acuity, or result in observed slowed growth, but it could place children at a risk for insufficient nutritional intake, consequently impairing growth and general health. The results emphasize the parental role in shaping children's diet and provide information for developing strategies to reduce PW of individual children.

  11. Effectiveness of training programmes used in two stables of thoroughbred race horses.

    Science.gov (United States)

    Szarska, E; Cywińska, A; Ostaszewski, P; Kowalska, A

    2014-01-01

    The purpose of this study was to compare the training methods used in two stables and their effects on selected blood parameters and race results. A total number of 36 thoroughbred race horses was examined in two groups, trained by two trainers. Twenty-four horses (group A) were trained at Sluzewiec and the remaining twelve horses (group B) were kept and trained in a private stable. The experiment lasted for five months. The activities of CPK (creatine phosphokinase) and AST (aspartate aminotransferase) and the concentration of LA (lactic acid) were determined. The speed was controlled and recorded by a Garmin GPS system. The analysis of the General Handicap rating demonstrated that the training methods used in stable A were more effective and resulted in better classification of these horses. Training methods in both stables were evaluated and compared on the basis of maximal speeds during training sessions and related post exercise LA concentrations. The main differences between training methods used in both stables concerned the workload and the time of work with the rider. Analysis of the values measured in individual horses from stable B have shown that AST and CK activities were high not only in all young, 2-year-old horses but also in three older ones. This seems to confirm the lack of balance and proper movement coordination in these horses, resulting in high activities of muscle enzymes.

  12. Osteoprotegerin independently predicts mortality in patients with stable coronary artery disease: the CLARICOR trial

    DEFF Research Database (Denmark)

    Bjerre, Mette; Hilden, Jørgen; Kastrup, Jens

    2014-01-01

    OBJECTIVES: To elucidate the prognostic power of serum osteoprotegerin (OPG) in patients with stable coronary artery disease (CAD). METHODS: Serum OPG levels were measured in the CLARICOR trial cohort of 4063 patients with stable CAD on blood samples drawn at randomization. The follow-up was 2...... predictor for all-cause mortality. Importantly, OPG remained an independent predictor of mortality even after adjustment for both clinical and conventional cardiovascular risk markers (HR 2.5 [95% CI 1.6-3.9, p power as to all...

  13. To Further the Near-Vision Visual Acuity Tests (3): For a Test Which Saves Time, Labor, and Expenses

    OpenAIRE

    高橋, ひとみ; 川端, 秀仁; 衞藤, 隆

    2014-01-01

    The Ministry of Education, Culture, Sports, Science and Technology of Japan has its advisory board to review the list of medical checkup for school children every ten years. In August 2013 the board found that there was a considerable number of school children who had poor near vision and thus learn in the class less efficiently. The board recommended that the Ministry consider whether to include a near-vision visual acuity test in a regular medical examination at school. It may not be known ...

  14. Stable, precise, and reproducible patterning of bicoid and hunchback molecules in the early Drosophila embryo.

    Directory of Open Access Journals (Sweden)

    Yurie Okabe-Oho

    2009-08-01

    Full Text Available Precise patterning of morphogen molecules and their accurate reading out are of key importance in embryonic development. Recent experiments have visualized distributions of proteins in developing embryos and shown that the gradient of concentration of Bicoid morphogen in Drosophila embryos is established rapidly after fertilization and remains stable through syncytial mitoses. This stable Bicoid gradient is read out in a precise way to distribute Hunchback with small fluctuations in each embryo and in a reproducible way, with small embryo-to-embryo fluctuation. The mechanisms of such stable, precise, and reproducible patterning through noisy cellular processes, however, still remain mysterious. To address these issues, here we develop the one- and three-dimensional stochastic models of the early Drosophila embryo. The simulated results show that the fluctuation in expression of the hunchback gene is dominated by the random arrival of Bicoid at the hunchback enhancer. Slow diffusion of Hunchback protein, however, averages out this intense fluctuation, leading to the precise patterning of distribution of Hunchback without loss of sharpness of the boundary of its distribution. The coordinated rates of diffusion and transport of input Bicoid and output Hunchback play decisive roles in suppressing fluctuations arising from the dynamical structure change in embryos and those arising from the random diffusion of molecules, and give rise to the stable, precise, and reproducible patterning of Bicoid and Hunchback distributions.

  15. The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

    Science.gov (United States)

    Peters, B. T.; Mulavara, A. P.; Brady, R.; Miller, C. A.; Richards, J. T.; Warren, L. E.; Cohen, H. S.; Bloomberg, J. J.

    2006-01-01

    After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The

  16. Visual training paired with electrical stimulation of the basal forebrain improves orientation-selective visual acuity in the rat.

    Science.gov (United States)

    Kang, Jun Il; Groleau, Marianne; Dotigny, Florence; Giguère, Hugo; Vaucher, Elvire

    2014-07-01

    The cholinergic afferents from the basal forebrain to the primary visual cortex play a key role in visual attention and cortical plasticity. These afferent fibers modulate acute and long-term responses of visual neurons to specific stimuli. The present study evaluates whether this cholinergic modulation of visual neurons results in cortical activity and visual perception changes. Awake adult rats were exposed repeatedly for 2 weeks to an orientation-specific grating with or without coupling this visual stimulation to an electrical stimulation of the basal forebrain. The visual acuity, as measured using a visual water maze before and after the exposure to the orientation-specific grating, was increased in the group of trained rats with simultaneous basal forebrain/visual stimulation. The increase in visual acuity was not observed when visual training or basal forebrain stimulation was performed separately or when cholinergic fibers were selectively lesioned prior to the visual stimulation. The visual evoked potentials show a long-lasting increase in cortical reactivity of the primary visual cortex after coupled visual/cholinergic stimulation, as well as c-Fos immunoreactivity of both pyramidal and GABAergic interneuron. These findings demonstrate that when coupled with visual training, the cholinergic system improves visual performance for the trained orientation probably through enhancement of attentional processes and cortical plasticity in V1 related to the ratio of excitatory/inhibitory inputs. This study opens the possibility of establishing efficient rehabilitation strategies for facilitating visual capacity.

  17. The first millennium AD climate fluctuations in the Tavoliere Plain (Apulia, Italy): New preliminary data from the 14C AMS-dated plant remains from the archaeological site of Faragola

    International Nuclear Information System (INIS)

    Fiorentino, G.; Caracuta, V.; Volpe, G.; Turchiano, M.; Quarta, G.; D'Elia, M.; Calcagnile, L.

    2010-01-01

    The identification of ancient climate fluctuations represents an hard challenge for studies intended to outline the human-environment interaction in fragile ecosystems. The aim of this work is to test the potentialities of carbon stable isotopic content of AMS-dated archaeological plant remains as tool to infer variations in rainfall/temperature regimes. The results obtained in the analysis of the carbon stable isotopic content of 10 plant remains selected among the archaeobotanical remains collected at the archaeological site in Faragola (Apulia, Italy) and radiocarbon-dated by AMS are presented. The variation of δ 13 C values was considered on a chronological scale covering a time range comprised between the II century BC and the VII century AD. The obtained patterns were also compared with local and global-scale palaeoclimatic records.

  18. Quality of life and visual acuity outcomes in the Registry in Glaucoma Outcomes Research study.

    Science.gov (United States)

    Coleman, Anne L; Lum, Flora C; Gliklich, Richard E; Velentgas, Priscilla; Su, Zhaohui

    2016-01-01

    The RiGOR study evaluated the association of treatment and patient-reported outcomes for open-angle glaucoma patients. The Glaucoma Symptom Scale (National Eye Institute-Visual Function Questionnaire (NEI-VFQ) and visual acuity (VA) were collected as quality of life measures. The proportion of patients with improvement of at least two lines of vision was highest in the incisional surgery group (14.2% compared with 9.9% for laser surgery and 10.9% for additional medication). No clinically relevant differences were seen in benefit for the laser surgery or incisional surgery groups compared with additional medications for the Glaucoma Symptom Scale or NEI-VFQ measures or subscales. Differences in quality of life by race need to be explored in further studies.

  19. Personality stability is associated with better cognitive performance in adulthood: are the stable more able?

    Science.gov (United States)

    Graham, Eileen K; Lachman, Margie E

    2012-09-01

    Although personality is relatively stable over time, there are individual differences in the patterns and magnitude of change. There is some evidence that personality change in adulthood is related to physical health and longevity. The present study expanded this work to consider whether personality stability or change would be associated with better cognitive functioning, especially in later adulthood. A total of 4,974 individuals participated in two waves of The Midlife in the United States Study (MIDUS) in 1994-1995 and 2004-2005. Participants completed the MIDUS personality inventory at both times and the Brief Test of Adult Cognition by Telephone cognitive battery at Time 2. Multiple regression and analysis of covariance analyses showed that, consistent with predictions, individuals remaining stable in openness to experience and neuroticism had faster reaction times and better inductive reasoning than those who changed. Among older adults, those who remained stable or decreased in neuroticism had significantly faster reaction times than those who increased. As predicted, personality stability on some traits was associated with more adaptive cognitive performance on reasoning and reaction time. Personality is discussed as a possible resource for protecting against or minimizing age-related declines in cognition.

  20. Using the Freiburg Acuity and Contrast Test to measure visual performance in USAF personnel after PRK.

    Science.gov (United States)

    Dennis, Richard J; Beer, Jeremy M A; Baldwin, J Bruce; Ivan, Douglas J; Lorusso, Frank J; Thompson, William T

    2004-07-01

    Photorefractive keratectomy (PRK) may be an alternative to spectacle and contact lens wear for United States Air Force (USAF) aircrew and may offer some distinct advantages in operational situations. However, any residual corneal haze or scar formation from PRK could exacerbate the disabling effects of a bright glare source on a complex visual task. The USAF recently completed a longitudinal clinical evaluation of the long-term effects of PRK on visual performance, including the experiment described herein. After baseline data were collected, 20 nonflying active duty USAF personnel underwent PRK. Visual performance was then measured at 6, 12, and 24 months after PRK. Visual acuity (VA) and contrast sensitivity (CS) data were collected by using the Freiburg Acuity and Contrast Test (FrACT), with the subject viewing half of the runs through a polycarbonate windscreen. Experimental runs were completed under 3 glare conditions: no glare source and with either a broadband or a green laser (532-nm) glare annulus (luminance approximately 6090 cd/m) surrounding the Landolt C stimulus. Systematic effects of PRK on VA relative to baseline were not identified. However, VA was almost 2 full Snellen lines worse with the laser glare source in place versus the broadband glare source. A significant drop-off was observed in CS performance after PRK under conditions of no glare and broadband glare; this was the case both with and without the windscreen. As with VA, laser glare disrupted CS performance significantly and more than broadband glare did. PRK does not appear to have affected VA, but the changes in CS might represent a true decline in visual performance. The greater disruptive effects from laser versus broadband glare may be a result of increased masking from coherent spatial noise (speckle) surrounding the laser stimulus.

  1. Finasteride for chronic central serous chorioretinopathy.

    Science.gov (United States)

    Forooghian, Farzin; Meleth, Annal D; Cukras, Catherine; Chew, Emily Y; Wong, Wai T; Meyerle, Catherine B

    2011-04-01

    To evaluate the safety and efficacy of finasteride, an inhibitor of dihydrotestosterone synthesis, in the treatment of chronic central serous chorioretinopathy. Five patients with chronic central serous chorioretinopathy were prospectively enrolled in this pilot study. Patients were administered finasteride (5 mg) daily for 3 months, after which study medication was withheld and patients were observed for 3 months. Main outcome measures included best-corrected visual acuity, central subfield macular thickness, and subretinal fluid volume as assessed by optical coherence tomography. Serum dihydrotestosterone, serum testosterone, and urinary cortisol were also measured. There was no change in mean best-corrected visual acuity. Mean center-subfield macular thickness and subretinal fluid volume reached a nadir at 3 months and rose to levels that were below baseline by 6 months. The changes in both optical coherence tomography parameters paralleled those in serum dihydrotestosterone level. In four patients, center-subfield macular thickness and/or subretinal fluid volume increased after discontinuation of finasteride. In the remaining patient, both optical coherence tomography parameters normalized with finasteride and remained stable when the study medication was discontinued. Finasteride may represent a novel medical treatment for chronic central serous chorioretinopathy. Larger controlled clinical trials are needed to further assess the efficacy of finasteride for the treatment of central serous chorioretinopathy.

  2. Higher-order aberrations and visual acuity after LASEK.

    Science.gov (United States)

    Urgancioglu, Berrak; Bilgihan, Kamil; Ozturk, Sertac

    2008-08-01

    To determine ocular higher-order aberrations (HOAs) in eyes with supernormal vision after myopic astigmatic laser subepithelial keratomileusis (LASEK) and to compare the findings with those in eyes with natural supernormal vision. Ocular HOAs were measured after LASEK in 20 eyes of 12 myopic astigmatic patients with postoperative uncorrected visual acuity (UCVA) of >20/16 (group 1). Patients who were included in the study had no visual symptoms like glare, halo or double vision. The measurements were taken 8.3 +/- 3 months after LASEK surgery. In group 2 ocular HOAs were examined in 20 eyes of 10 subjects with natural UCVA of >20/16 as a control. Measurements were taken across a pupil with a diameter of 4.0 mm and 6.0 mm. Root-mean-square (RMS) values of HOAs, Z(3)-1, Z(3)1, Z(4)0, Z(5)-1, Z(5)1 and Z(6)0 were analyzed. The mean RMS values for each order were higher in group 1 when compared with group 2 at 4.0 mm and 6.0 mm pupil diameters. There was no statistically significant difference between groups in spherical and coma aberrations (P > 0.05). Mean RMS values for total HOAs were 0.187 +/- 0.09 microm at 4.0 mm and 0.438 +/- 0.178 microm at 6.0 mm pupil in group 1 and 0.120 +/- 0.049 microm at 4.0 mm and 0.344 +/- 0.083 microm at 6.0 mm pupil in group 2. The difference between groups in total HOAs was statistically significant at 4.0 mm and 6.0 mm pupil diameters (P < 0.05). Ocular HOAs exist in eyes with supernormal vision. After LASEK, the amount of HOAs of the eye increases under both mesopic and photopic conditions. However the amount of HOA increase does not seem to be consistent with visual symptoms.

  3. Visual acuity with simulated and real astigmatic defocus.

    Science.gov (United States)

    Ohlendorf, Arne; Tabernero, Juan; Schaeffel, Frank

    2011-05-01

    To compare the effects of "simulated" and "real" spherical and astigmatic defocus on visual acuity (VA). VA was determined with letter charts that were blurred by calculated spherical or astigmatic defocus (simulated defocus) or were seen through spherical or astigmatic trial lenses (real defocus). Defocus was simulated using ZEMAX and the Liou-Brennan eye model. Nine subjects participated [mean age, 27.2 ± 1.8 years; logarithm of the minimum angle of resolution (logMAR), -0.1]. Three different experiments were conducted in which VA was reduced by 20% (logMAR 0.0), 50% (logMAR 0.2), or 75% (logMAR 0.5) by either (1) imposing positive spherical defocus, (2) imposing positive and negative astigmatic defocus in three axes (0, 45, and 90°), and (3) imposing cross-cylinder defocus in the same three axes as in (2). Experiment (1): there were only minor differences in VA with simulated and real positive spherical defocus. Experiment (2): simulated astigmatic defocus reduced VA twice as much as real astigmatic defocus in all tested axes (p < 0.01 in all cases). Experiment (3): simulated cross-cylinder defocus reduced VA much more than real cross-cylinder defocus (p < 0.01 in all cases), similarly for all three tested axes. The visual system appears more tolerant against "real" spherical, astigmatic, and cross-cylinder defocus than against "simulated" blur. Possible reasons could be (1) limitations in the modeling procedures to simulate defocus, (2) higher ocular aberrations, and (3) fluctuations of accommodation. However, the two optical explanations (2) and (3) cannot account for the magnitude of the effect, and (1) was carefully analyzed. It is proposed that something may be special about the visual processing of real astigmatic and cross-cylinder defocus-because they have less effect on VA than simulations predict.

  4. One-dimensional stable distributions

    CERN Document Server

    Zolotarev, V M

    1986-01-01

    This is the first book specifically devoted to a systematic exposition of the essential facts known about the properties of stable distributions. In addition to its main focus on the analytic properties of stable laws, the book also includes examples of the occurrence of stable distributions in applied problems and a chapter on the problem of statistical estimation of the parameters determining stable laws. A valuable feature of the book is the author's use of several formally different ways of expressing characteristic functions corresponding to these laws.

  5. Validation of ICD-9 Codes for Stable Miscarriage in the Emergency Department.

    Science.gov (United States)

    Quinley, Kelly E; Falck, Ailsa; Kallan, Michael J; Datner, Elizabeth M; Carr, Brendan G; Schreiber, Courtney A

    2015-07-01

    International Classification of Disease, Ninth Revision (ICD-9) diagnosis codes have not been validated for identifying cases of missed abortion where a pregnancy is no longer viable but the cervical os remains closed. Our goal was to assess whether ICD-9 code "632" for missed abortion has high sensitivity and positive predictive value (PPV) in identifying patients in the emergency department (ED) with cases of stable early pregnancy failure (EPF). We studied females ages 13-50 years presenting to the ED of an urban academic medical center. We approached our analysis from two perspectives, evaluating both the sensitivity and PPV of ICD-9 code "632" in identifying patients with stable EPF. All patients with chief complaints "pregnant and bleeding" or "pregnant and cramping" over a 12-month period were identified. We randomly reviewed two months of patient visits and calculated the sensitivity of ICD-9 code "632" for true cases of stable miscarriage. To establish the PPV of ICD-9 code "632" for capturing missed abortions, we identified patients whose visits from the same time period were assigned ICD-9 code "632," and identified those with actual cases of stable EPF. We reviewed 310 patient records (17.6% of 1,762 sampled). Thirteen of 31 patient records assigned ICD-9 code for missed abortion correctly identified cases of stable EPF (sensitivity=41.9%), and 140 of the 142 patients without EPF were not assigned the ICD-9 code "632"(specificity=98.6%). Of the 52 eligible patients identified by ICD-9 code "632," 39 cases met the criteria for stable EPF (PPV=75.0%). ICD-9 code "632" has low sensitivity for identifying stable EPF, but its high specificity and moderately high PPV are valuable for studying cases of stable EPF in epidemiologic studies using administrative data.

  6. Bi-stable optical actuator

    Science.gov (United States)

    Holdener, Fred R.; Boyd, Robert D.

    2000-01-01

    The present invention is a bi-stable optical actuator device that is depowered in both stable positions. A bearing is used to transfer motion and smoothly transition from one state to another. The optical actuator device may be maintained in a stable position either by gravity or a restraining device.

  7. The calcineurin activity profiles of cyclosporin and tacrolimus are different in stable renal transplant patients

    DEFF Research Database (Denmark)

    Koefoed-Nielsen, Pernille Bundgaard; Karamperis, Nikolaos; Jørgensen, Kaj Anker

    2006-01-01

    in determining optimal doses. Forty stable renal transplant patients were investigated three times in a 6-month period. Blood samples were drawn at 0, 1, 2, 3 and 4 h after oral intake of tacrolimus (FK) or cyclosporin at days 1 and 180. At day 90, one blood sample at trough level (FK) or C2 level (cyclosporin A...... significantly different effects on calcineurin activity in renal transplant patients with stable, well-functioning grafts and that tacrolimus-treated patients can maintain good, stable graft function with minimal CaN inhibition.......Cyclosporin and tacrolimus remain the cornerstone immunosuppressive drugs in organ transplantation. Dosing and monitoring these drugs is based on pharmacokinetic protocols, but measuring a pharmacodynamic parameter, calcineurin phosphatase (CaN) activity, could be a valuable supplement...

  8. Dynamic visual acuity during transient and sinusoidal yaw rotation in normal and unilaterally vestibulopathic humans.

    Science.gov (United States)

    Tian, J R; Shubayev, I; Demer, J L

    2001-03-01

    The vestibulo-ocular reflex (VOR) stabilizes gaze to permit clear vision during head movements. It has been supposed that VOR function might be inferred from dynamic visual acuity (DVA), the acuity during imposed head motion. We sought to determine effectiveness of DVA for detection and lateralization of unilateral vestibulopathy, using rigorous psychophysical methods. Seventeen normal and 11 unilaterally vestibulopathic subjects underwent measurement of optically best corrected DVA during head motion. A variable size letter "E" 6 m distant was displayed in oblique random orientations to determine binocular DVA by a computer controlled, forced choice method. Three types of whole-body yaw rotation were delivered by a servo-controlled chair synchronized with optotype presentation. Two types of motion were predictable: (1) steady-state 2.0-Hz rotation at 10-130 degrees/s peak velocity with repetitive optotype presentation only during head velocity exceeding 80% of peak; and (2) directionally predictable transients at peak accelerations of 1000, 1600 and 2800 degrees/s2 with optotype presentation for 300 ms. For neither of these predictable motions did DVA in vestibulopathic subjects significantly differ from normal, with suggestions from search coil recordings that this was due to predictive slow and saccadic eye movements. Unilaterally vestibulopathic subjects experienced a significant decrease in DVA from the static condition during ipsilesional rotation for all three peak head accelerations. Only during directionally unpredictable transients with 75 ms or 300 ms optotype presentation was the sensitivity of DVA in unilaterally vestibulopathic subjects significantly abnormal during ipsilesional rotation. The ipsilesional decrease in DVA with head motion was greater for 75 ms than 300 ms optotype presentation. Search coil recordings confirmed hypometric compensatory eye movements during DVA testing with unpredictable, ipsilesional rotation. Receiver

  9. Effect of the Administration of Alpha-Lipoic Acid on Contrast Sensitivity in Patients with Type 1 and Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Anna Gębka

    2014-01-01

    Full Text Available The aim of this study was to estimate the effects of oral supplementation of alpha-lipoic acid (ALA on contrast sensitivity (CS in patients with type 1 diabetes mellitus (T1DM and type 2 diabetes mellitus (T2DM. The study included 12 patients with T1DM aged 43±12 years, 48 patients with T2DM aged 59±10 years, and 20 control subjects aged 33±8 years. Patients from each studied group, including the control group, were randomly assigned to receive 300 mg of ALA orally once daily for 3 months. CS was evaluated with the Functional Acuity Contrast Test (FACT, Stereo Optical. In the group of patients with T1DM receiving ALA for 3 months CS remained stable and improved in those with T2DM. Reduction of CS in both T1DM and T2DM patients without alpha-lipoic acid supplementation was observed. In the control group on alpha-lipoic acid supplementation, CS improvement was noticed at one spatial frequency. Changes in the CS were observed, despite stable visual acuity and eye fundus image in all studied subjects. Our study demonstrated that oral administration of alpha-lipoic acid had influence on CS in both T1DM and T2DM patients.

  10. Stable isotope fractionation during bacterial sulfate reduction is controlled by reoxidation of intermediates

    Science.gov (United States)

    Mangalo, Muna; Meckenstock, Rainer U.; Stichler, Willibald; Einsiedl, Florian

    2007-09-01

    Bacterial sulfate reduction is one of the most important respiration processes in anoxic habitats and is often assessed by analyzing the results of stable isotope fractionation. However, stable isotope fractionation is supposed to be influenced by the reduction rate and other parameters, such as temperature. We studied here the mechanistic basics of observed differences in stable isotope fractionation during bacterial sulfate reduction. Batch experiments with four sulfate-reducing strains ( Desulfovibrio desulfuricans, Desulfobacca acetoxidans, Desulfonatronovibrio hydrogenovorans, and strain TRM1) were performed. These microorganisms metabolize different carbon sources (lactate, acetate, formate, and toluene) and showed broad variations in their sulfur isotope enrichment factors. We performed a series of experiments on isotope exchange of 18O between residual sulfate and ambient water. Batch experiments were conducted with 18O-enriched (δ 18O water = +700‰) and depleted water (δ 18O water = -40‰), respectively, and the stable 18O isotope shift in the residual sulfate was followed. For Desulfovibrio desulfuricans and Desulfonatronovibrio hydrogenovorans, which are both characterized by low sulfur isotope fractionation ( ɛS > -13.2‰), δ 18O values in the remaining sulfate increased by only 50‰ during growth when 18O-enriched water was used for the growth medium. In contrast, with Desulfobacca acetoxidans and strain TRM1 ( ɛS factor ( ɛS exchange with water during sulfate reduction. However, this neither takes place in the sulfate itself nor during formation of APS (adenosine-5'-phosphosulfate), but rather in intermediates of the sulfate reduction pathway. These may in turn be partially reoxidized to form sulfate. This reoxidation leads to an incorporation of oxygen from water into the "recycled" sulfate changing the overall 18O isotopic composition of the remaining sulfate fraction. Our study shows that such incorporation of 18O is correlated with the

  11. Stable Isotopes and Oral Tori in Greenlandic Norse and Inuit

    DEFF Research Database (Denmark)

    Baumann, M.; Lynnerup, N.; Scott, G. R.

    2017-01-01

    Palatine (PT) and mandibular torus (MT) have long been of interest to dental researchers and anthropologists, but their aetiology remains unresolved. Some combination of genetic and environmental factors influences their expression, but the relative role of each remains contentious. Previous...... research has shown that the Greenlandic Norse exhibit exceptionally high frequencies and pronounced expressions of PT and MT. In this regard, they are significantly different from genetically related medieval Scandinavian populations, so environmental factors have to be considered. An earlier study...... that estimated stable carbon and nitrogen isotope compositions for a Greenlandic Norse sample makes it possible to compare directly PT and MT expression with the relative degree of marine protein intake. For comparative purposes, parallel observations were made on a Greenlandic Inuit sample. Some researchers...

  12. Remarks on stable and quasi-stable k-strings at large N

    International Nuclear Information System (INIS)

    Armoni, A.; Shifman, M.

    2003-01-01

    We discuss k-strings in the large-N Yang-Mills theory and its supersymmetric extension. Whereas the tension of the bona fide (stable) QCD string is expected to depend only on the N-ality of the representation, tensions that depend on specific representation R are often reported in the lattice literature. In particular, adjoint strings are discussed and found in certain simulations. We clarify this issue by systematically exploiting the notion of the quasi-stable strings which becomes well-defined at large N. The quasi-stable strings with representation-dependent tensions decay, but the decay rate (per unit length per unit time) is suppressed as Λ 2 F(N) where F(N) falls off as a function of N. It can be determined on the case-by-case basis. The quasi-stable strings eventually decay into stable strings whose tension indeed depends only on the N-ality. We also briefly review large-N arguments showing why the Casimir formula for the string tension cannot be correct, and present additional arguments in favor of the sine formula. Finally, we comment on the relevance of our estimates to Euclidean lattice measurements

  13. Clinical manifestations of optic pit maculopathy as demonstrated by spectral domain optical coherence tomography.

    Science.gov (United States)

    Tzu, Jonathan H; Flynn, Harry W; Berrocal, Audina M; Smiddy, William E; Murray, Timothy G; Fisher, Yale L

    2013-01-01

    The purpose of this retrospective study was to evaluate the characteristic features, including spectral-domain optical coherence tomography (SD-OCT), clinical course, and outcome of treatment if given for patients with optic disc pit maculopathy. We investigated a consecutive series of patients with a diagnosis of optic pit maculopathy treated between 2001 and 2012 at the Bascom Palmer Eye Institute. Patients were divided into two main groups, ie, patients who were observed without surgery and patients who received surgical intervention. The main outcome measures were presenting and final visual acuity, and changes in SD-OCT imaging were recorded. Other data including age, gender, eye, age of onset, length of follow-up, location of optic pit, and location of fluid by OCT were also recorded. On OCT, 67% (12/18) of the eyes showed schisis-like cavities, 22% (4/18) had only subretinal fluid, and 17% (3/18) had only a schisis-like cavity without subretinal fluid. In the patients managed by observation, visual acuity was ≥20/200 in 6/8 eyes initially and 6/8 eyes at last follow-up. Ten of 18 patients received either focal laser, surgery or both. Six of 10 eyes undergoing surgery had initial visual acuity ≥ 20/200, and 8 of 10 eyes undergoing surgery had a visual acuity of ≥20/200 at last follow-up. In this study, many eyes were observed and remained stable during follow-up. In eyes with reduced vision, surgical intervention produced variable outcomes, and persistent intraretinal/subretinal fluid was a common occurrence.

  14. Application of a portable microcomputer mental acuity battery for fitness-for-duty assessment in power plant operations

    International Nuclear Information System (INIS)

    Kennedy, R.S.; Turnage, J.T.; Lane, N.E.

    1988-01-01

    A need exists for assessment of fitness-for-duty in power plants. Several microcomputer-based mental acuity test batteries are under development for objective assessment of human performance over repeated measures. One of these, the Automated Performance Test System (APTS), has been shown to be sensitive to various environments and treatments and could prove useful for this purpose. Tests from these batteries should be studied during the naturally occurring stresses of power plant activity (e.g., shift work, sustained operations, sleep deprivation, stressful periods) in order to establish the effects of such issues on performance, and to provide insights and scientific data for the development of standards and regulations

  15. Evolutionary Stable Strategy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 21; Issue 9. Evolutionary Stable Strategy: Application of Nash Equilibrium in Biology. General Article Volume 21 Issue 9 September 2016 pp 803- ... Keywords. Evolutionary game theory, evolutionary stable state, conflict, cooperation, biological games.

  16. Retinal detachment and retinal holes in retinitis pigmentosa sine pigmento.

    Science.gov (United States)

    Csaky, K; Olk, R J; Mahl, C F; Bloom, S M

    1991-01-01

    Retinal detachment and retinal holes in two family members with retinitis pigmentosa sine pigmento are reported. We believe these are the first such cases reported in the literature. We describe the presenting symptoms and management, including cryotherapy, scleral buckling procedure, and sulfur hexafluoride injection (SF6), resulting in stable visual acuity in one case and retinal reattachment and improved visual acuity in the other case.

  17. Complex cobordism and stable homotopy groups of spheres

    CERN Document Server

    Ravenel, Douglas C

    2003-01-01

    Since the publication of its first edition, this book has served as one of the few available on the classical Adams spectral sequence, and is the best account on the Adams-Novikov spectral sequence. This new edition has been updated in many places, especially the final chapter, which has been completely rewritten with an eye toward future research in the field. It remains the definitive reference on the stable homotopy groups of spheres. The first three chapters introduce the homotopy groups of spheres and take the reader from the classical results in the field though the computational aspects

  18. Higher order optical aberrations and visual acuity in a randomized controlled trial comparing transepithelial versus epithelium-off corneal crosslinking for progressive keratoconus

    Directory of Open Access Journals (Sweden)

    Godefrooij DA

    2017-10-01

    Full Text Available Daniel A Godefrooij, Mustapha El Kandoussi, Nienke Soeters, Robert PL Wisse Utrecht Cornea Research Group, Department of Ophthalmology, University Medical Center Utrecht, Utrecht, the Netherlands Purpose: The purpose of this study was to compare the effects of transepithelial crosslinking (trans-CXL versus epithelium-off crosslinking (epi-off CXL for progressive keratoconus with respect to the development of higher order aberrations (HOAs and their effects on visual acuity.Materials and methods: A total of 61 patients were randomized and examined preoperatively and 1, 3, 6, and 12 months postoperatively in an academic referral center. Total corneal HOAs were compared between the two treatment groups using mixed linear modeling. Types of HOAs (coma, trefoil, and spherical aberration that differed between groups were entered in a multivariable analysis to test their effect on uncorrected distance visual acuity (UDVA and corrected distance visual acuity (CDVA.Results: The epi-off CXL group had more flattening in maximal keratometry compared to the trans-CXL group (P=0.02. UDVA did not differ significantly between the groups (P=0.59; however, CDVA was significantly more improved in the trans-CXL group (P=0.02. Horizontal trefoil improved more in the epi-off group compared to the trans-CXL group (P=0.04, whereas the other HOAs were virtually unchanged in both groups. Differences in changes in HOAs between the two groups had no effect on either UCVA (P=0.76 or CDVA (P=0.96.Conclusion: Although HOAs are clinically relevant determinants of vision quality in keratoconus patients, the change in total HOAs post treatment did not differ between the trans-CXL and epi-off CXL groups. Only horizontal trefoil differed significantly post treatment between the trans-CXL and epi-off CXL groups. However, this difference did not independently affect either UDVA or CDVA. Trans-CXL provides no benefit over epi-off CXL regarding visual relevant HOAs. Keywords

  19. Sex differences in the shoulder joint position sense acuity: a cross-sectional study.

    Science.gov (United States)

    Vafadar, Amir K; Côté, Julie N; Archambault, Philippe S

    2015-09-30

    Work-related musculoskeletal disorders (WMSD) is the most expensive form of work disability. Female sex has been considered as an individual risk factor for the development of WMSD, specifically in the neck and shoulder region. One of the factors that might contribute to the higher injury rate in women is possible differences in neuromuscular control. Accordingly the purpose of this study was to estimate the effect of sex on shoulder joint position sense acuity (as a part of shoulder neuromuscular control) in healthy individuals. Twenty-eight healthy participants, 14 females and 14 males were recruited for this study. To test position sense acuity, subjects were asked to flex their dominant shoulder to one of the three pre-defined angle ranges (low, mid and high-ranges) with eyes closed, hold their arm in that position for three seconds, go back to the starting position and then immediately replicate the same joint flexion angle, while the difference between the reproduced and original angle was taken as the measure of position sense error. The errors were measured using Vicon motion capture system. Subjects reproduced nine positions in total (3 ranges × 3 trials each). Calculation of absolute repositioning error (magnitude of error) showed no significant difference between men and women (p-value ≥ 0.05). However, the analysis of the direction of error (constant error) showed a significant difference between the sexes, as women tended to mostly overestimate the target, whereas men tended to both overestimate and underestimate the target (p-value ≤ 0.01, observed power = 0.79). The results also showed that men had a significantly more variable error, indicating more variability in their position sense, compared to women (p-value ≤ 0.05, observed power = 0.78). Differences observed in the constant JPS error suggest that men and women might use different neuromuscular control strategies in the upper limb. In addition, higher JPS

  20. A Bayesian least-squares support vector machine method for predicting the remaining useful life of a microwave component

    Directory of Open Access Journals (Sweden)

    Fuqiang Sun

    2017-01-01

    Full Text Available Rapid and accurate lifetime prediction of critical components in a system is important to maintaining the system’s reliable operation. To this end, many lifetime prediction methods have been developed to handle various failure-related data collected in different situations. Among these methods, machine learning and Bayesian updating are the most popular ones. In this article, a Bayesian least-squares support vector machine method that combines least-squares support vector machine with Bayesian inference is developed for predicting the remaining useful life of a microwave component. A degradation model describing the change in the component’s power gain over time is developed, and the point and interval remaining useful life estimates are obtained considering a predefined failure threshold. In our case study, the radial basis function neural network approach is also implemented for comparison purposes. The results indicate that the Bayesian least-squares support vector machine method is more precise and stable in predicting the remaining useful life of this type of components.

  1. Botulinum Toxin as an Alternative to Treat the Spasm of the Near Reflex.

    Science.gov (United States)

    Laria, Carlos; Merino-Suárez, María L; Piñero, David P; Gómez-Hurtado, Arantxa; Pérez-Cambrodí, Rafael J

    2015-01-01

    We describe the case of an eight-year-old girl with complaints of headaches and blurred vision (uncorrected visual acuity: 0.1 decimal) that showed on examination miotic pupils, pseudomyopia, no ocular motility restrictions, and no associated neurological disease. After initial treatment with cyclopentolate for two months, pseudomyopia persisted with an intermittent and variable esotropia. Spectacles of +1 both eyes and atropine 1% one drop daily were then prescribed. The situation improved and remained stable for several weeks, with pseudomyopia and esotropia reappearing later. Finally, botulinum toxin (2.5 iu Botox) was injected in the medial rectus muscle on two occasions and a visual therapy program based on the stimulation of fusional divergence, diplopia, and stereopsis consciousness was recommended. This prescription was combined with the use of atropine during the first few weeks. Orthotropia and corrected distance visual acuity of 1.0 were found three months after treatment. The evolution and clinical results of this case report suggest that botulinum toxin in combination with other therapeutic alternatives may be useful in the treatment of spasm of the near reflex.

  2. Relation between Visual Acuity and Slope of Psychometric Function in Young Adults

    Directory of Open Access Journals (Sweden)

    Tomoki Tokutake

    2011-05-01

    Full Text Available Mita et al. (2010 devised a technique of comparing a visual acuity (VA change in an individual with more accurate VA than conventional VA tests by significant difference examined logarithmic (Log VA ± standard deviation (SD. Using this technique, in this study, we examined a relation between VA and the slope of the psychometric function in normal young subjects. Six occlusion foil conditions were employed (1.0, 0.8, 0.6, 0.4, 0.1 and without the foil under a full refractive correction. Ten normal young adults (22.8 years old on average who have no ophthalmologic disease except ametropia participated in the measurement. The experiment was carried out with the constant method, a series of ten Landolt rings were used and each ring was presented 20 times randomly in a measurement. A 5.6-inch type of liquid crystal display driven by a computer, which has 1,280×800 pixels spatial resolution, was used to present the stimulus. In the normal young adults, the slope of the psychometric function did not change as the VA change systematically, and there was almost no correlation between them (r = −0.103.

  3. Prenatal Co 60-irradiation effects on visual acuity, maturation of the fovea in the retina, and the striate cortex of squirrel monkey offspring

    International Nuclear Information System (INIS)

    Ordy, J.M.; Brizzee, K.R.; Young, R.

    1982-01-01

    In the present study, foveal striate cortex depth increased significantly from 1400 μm to 1650 μm by 90 days, whereas prenatal 100 rad exposure resulted in a significant reduction of foveal striate cortex thickness at 90 days of age. From birth to 90 days, cell packing density decreased, whereas overall neuropil density increased in both control and 100 rad exposed offspring. Regarding the effects of prenatal radiation on Meynert cells, there was a significant difference in the time course of early postnatal spine frequency reduction on apical dendrites of Meynert cells, particularly in laminae V and IV. It seems possible that the significant differences in the time course of perinatal increases and subsequent decreases of spines and synapses on such pyramidal neurons as Meynert cells in the deep layers of the striate cortex may play an important role in the development of binocular acuity. Future follow-up studies will be essential from 90 days to 1 and 2 years to determine the extent of recovery from, and persistence of visual acuity impairments in relation to structural alterations in the foveal projection of the retino-geniculo-striate system of diurnal primates. (orig./MG)

  4. Age norms for monocular grating acuity measured by sweep-VEP in the first three years of age Estudo normativo de acuidade visual de resolução de grades medido pelo PVE de varredura nos três primeiros anos de vida

    Directory of Open Access Journals (Sweden)

    Solange Rios Salomão

    2008-08-01

    Full Text Available PURPOSE: To determine age norms for grating visual acuity and interocular acuity differences measured by the sweep-visually evoked potentials (VEP technique in the first three years of life. METHODS: Monocular grating visual acuity was measured using the sweep-VEP in 67 healthy normal infants and children in the first 36 months of life. RESULTS: Sweep-VEP grating acuity ranged from 0.80 logMAR (20/125 Snellen equivalent in the first month of life to 0.06 logMAR (20/20 Snellen equivalent at 36 months of age. Lower normal limits (95th percentile limit ranged from 0.95 logMAR (20/180 to 0.12 logMAR (20/25 with a progression of approximately 3 octaves in the first 36 months of age. The largest acceptable interocular acuity difference for clinical purposes was 0.10 logMAR. CONCLUSIONS: Age norms for grating acuity along with interocular acuity differences were determined using the sweep-VEP technique. These norms should be incorporated in clinical practice for precise diagnosis of visual status in infants and preverbal children.OBJETIVOS: Propor valores normativos de acuidade visual de grades e sua respectiva diferença interocular medidas pelo potencial visual evocado de varredura nos primeiros três anos de vida. MÉTODOS: Foram avaliadas 67 crianças sadias, sem doenças oculares, que tiveram a acuidade visual medida pelos potenciais evocados visuais de varredura. RESULTADOS: A acuidade visual média variou de 0,80 logMAR (equivalente de Snellen de 20/125 no primeiro mês de vida a 0,06 logMAR (equivalente de Snellen de 20/20 aos 36 meses. Os limites normais inferiores (percentil 95% variaram de 0,95 logMAR (20/180 a 0,12 logMAR (20/25 com progressão de aproximadamente 3 oitavas nos primeiros 36 meses de vida. A diferença interocular máxima aceitável foi de 0,10 logMAR. CONCLUSÕES: Os valores normativos de acuidade visual e de diferença interocular de acuidade foram obtidos pela técnica do potencial visual evocado de varredura. Prop

  5. A long-term stable power supply μDMFC stack for wireless sensor node applications

    International Nuclear Information System (INIS)

    Wu, Z L; Wang, X H; Teng, F; Li, X Z; Wu, X M; Liu, L T

    2013-01-01

    A passive, air-breathing 4-cell micro direct methanol fuel cell (μDMFC) stack is presented featured by a fuel delivery structure for a long-term and stable power supply. The fuel is reserved in a T shape tank and diffuses through the porous diffusion layer to the catalyst at anode. The stack has a maximum power output of 110mW with 3M methanol at room temperature and output a stable power even thought 5% fuel is the remained in reservoir. Its performance decreases less than 3% for 100 hours continuous work. As such, it is believed to be more applicable for powering the wireless sensor nodes

  6. Group living in squamate reptiles: a review of evidence for stable aggregations.

    Science.gov (United States)

    Gardner, Michael G; Pearson, Sarah K; Johnston, Gregory R; Schwarz, Michael P

    2016-11-01

    How sociality evolves and is maintained remains a key question in evolutionary biology. Most studies to date have focused on insects, birds, and mammals but data from a wider range of taxonomic groups are essential to identify general patterns and processes. The extent of social behaviour among squamate reptiles is under-appreciated, yet they are a promising group for further studies. Living in aggregations is posited as an important step in the evolution of more complex sociality. We review data on aggregations among squamates and find evidence for some form of aggregations in 94 species across 22 families. Of these, 18 species across 7 families exhibited 'stable' aggregations that entail overlapping home ranges and stable membership in long-term (years) or seasonal aggregations. Phylogenetic analysis suggests that stable aggregations have evolved multiple times in squamates. We: (i) identify significant gaps in our understanding; (ii) outline key traits which should be the focus of future research; and (iii) outline the potential for utilising reproductive skew theory to provide insights into squamate sociality. © 2015 Cambridge Philosophical Society.

  7. Stable Boundary Layer Issues

    OpenAIRE

    Steeneveld, G.J.

    2012-01-01

    Understanding and prediction of the stable atmospheric boundary layer is a challenging task. Many physical processes are relevant in the stable boundary layer, i.e. turbulence, radiation, land surface coupling, orographic turbulent and gravity wave drag, and land surface heterogeneity. The development of robust stable boundary layer parameterizations for use in NWP and climate models is hampered by the multiplicity of processes and their unknown interactions. As a result, these models suffer ...

  8. Wall-crossing between stable and co-stable ADHM data

    Science.gov (United States)

    Ohkawa, Ryo

    2018-06-01

    We prove formula between Nekrasov partition functions defined from stable and co-stable ADHM data for the plane following method by Nakajima and Yoshioka (Kyoto J Math 51(2):263-335, 2011) based on the theory of wall-crossing formula developed by Mochizuki (Donaldson type invariants for algebraic surfaces: transition of moduli stacks, Lecture notes in mathematics, vol 1972, Springer, Berlin, 2009). This formula is similar to conjectures by Ito et al. [J High Energy Phys 2013(5):045, 2013, (4.1), (4.2)] for A1 singularity.

  9. Stable Water Use Efficiency under Climate Change of Three Sympatric Conifer Species at the Alpine Treeline.

    Science.gov (United States)

    Wieser, Gerhard; Oberhuber, Walter; Gruber, Andreas; Leo, Marco; Matyssek, Rainer; Grams, Thorsten Erhard Edgar

    2016-01-01

    The ability of treeline associated conifers in the Central Alps to cope with recent climate warming and increasing CO2 concentration is still poorly understood. We determined tree ring stable carbon and oxygen isotope ratios of Pinus cembra, Picea abies, and Larix decidua trees from 1975 to 2010. Stable isotope ratios were compared with leaf level gas exchange measurements carried out in situ between 1979 and 2007. Results indicate that tree ring derived intrinsic water-use efficiency (iWUE) of P. cembra, P. abies and L. decidua remained constant during the last 36 years despite climate warming and rising atmospheric CO2. Temporal patterns in Δ(13)C and Δ(18)O mirrored leaf level gas exchange assessments, suggesting parallel increases of CO2-fixation and stomatal conductance of treeline conifer species. As at the study site soil water availability was not a limiting factor iWUE remained largely stable throughout the study period. The stability in iWUE was accompanied by an increase in basal area increment (BAI) suggesting that treeline trees benefit from both recent climate warming and CO2 fertilization. Finally, our results suggest that iWUE may not change species composition at treeline in the Austrian Alps due to similar ecophysiological responses to climatic changes of the three sympatric study species.

  10. [Epidemiological Study of Poor Visual Acuity among Schoolchildren in Bonin Islands].

    Science.gov (United States)

    Ito, Misae; Shimizu, Kimiya; Kawamorita, Takushi; Shoji, Nobuyuki

    2016-04-01

    To investigate the change in uncorrected visual acuity (UCVA) among schoolchildren in Bonin Islands. UCVA of schoolchildren aged 6 to 14 years, was collected from reports of School Health Examination Surveys conducted from 1981 to 2012. The proportion of schoolchildren with poor UCVA in the Bonin Islands was compared with those in metropolitan Tokyo. The results in Bonin Islands were also divided into two groups, before- and after-1996 when terrestrial television broadcasting service has been started, and the data of those two groups were compared. The proportion of schoolchildren with poor UCVA in Bonin Islands was lower than that in Tokyo. Among the residents of Bonin Islands, the proportion of schoolchildren with UCVA of < 1.0 was higher in the after-1996 group than in the before- 1996 group, with a clear increase in schoolchildren with poor UCVA after 1996 (p < 0.01, Fisher's exact test), examined among the 4th grade of elementary school or above. After 1996, 26.6% of first graders at a public junior high school had poor UCVA of < 0.7, whereas before 1996 no such case could be detected. The present study revealed that the proportions of schoolchildren with poor UCVA in Bonin Islands was lower than that in Tokyo; but in the residents of Bonin Islands after 1996, the proportion of the schoolchildren with poor UCVA increased.

  11. Angina Pectoris (Stable Angina)

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Angina Pectoris (Stable Angina) Updated:Aug 21,2017 You may have heard the term “angina pectoris” or “stable angina” in your doctor’s office, ...

  12. Normal modified stable processes

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole Eiler; Shephard, N.

    2002-01-01

    Gaussian (NGIG) laws. The wider framework thus established provides, in particular, for added flexibility in the modelling of the dynamics of financial time series, of importance especially as regards OU based stochastic volatility models for equities. In the special case of the tempered stable OU process......This paper discusses two classes of distributions, and stochastic processes derived from them: modified stable (MS) laws and normal modified stable (NMS) laws. This extends corresponding results for the generalised inverse Gaussian (GIG) and generalised hyperbolic (GH) or normal generalised inverse...

  13. Uses of stable isotopes

    International Nuclear Information System (INIS)

    Axente, Damian

    1998-01-01

    The most important fields of stable isotope use with examples are presented. These are: 1. Isotope dilution analysis: trace analysis, measurements of volumes and masses; 2. Stable isotopes as tracers: transport phenomena, environmental studies, agricultural research, authentication of products and objects, archaeometry, studies of reaction mechanisms, structure and function determination of complex biological entities, studies of metabolism, breath test for diagnostic; 3. Isotope equilibrium effects: measurement of equilibrium effects, investigation of equilibrium conditions, mechanism of drug action, study of natural processes, water cycle, temperature measurements; 4. Stable isotope for advanced nuclear reactors: uranium nitride with 15 N as nuclear fuel, 157 Gd for reactor control. In spite of some difficulties of stable isotope use, particularly related to the analytical techniques, which are slow and expensive, the number of papers reporting on this subject is steadily growing as well as the number of scientific meetings organized by International Isotope Section and IAEA, Gordon Conferences, and regional meeting in Germany, France, etc. Stable isotope application development on large scale is determined by improving their production technologies as well as those of labeled compound and the analytical techniques. (author)

  14. Entropy-stable summation-by-parts discretization of the Euler equations on general curved elements

    Science.gov (United States)

    Crean, Jared; Hicken, Jason E.; Del Rey Fernández, David C.; Zingg, David W.; Carpenter, Mark H.

    2018-03-01

    We present and analyze an entropy-stable semi-discretization of the Euler equations based on high-order summation-by-parts (SBP) operators. In particular, we consider general multidimensional SBP elements, building on and generalizing previous work with tensor-product discretizations. In the absence of dissipation, we prove that the semi-discrete scheme conserves entropy; significantly, this proof of nonlinear L2 stability does not rely on integral exactness. Furthermore, interior penalties can be incorporated into the discretization to ensure that the total (mathematical) entropy decreases monotonically, producing an entropy-stable scheme. SBP discretizations with curved elements remain accurate, conservative, and entropy stable provided the mapping Jacobian satisfies the discrete metric invariants; polynomial mappings at most one degree higher than the SBP operators automatically satisfy the metric invariants in two dimensions. In three-dimensions, we describe an elementwise optimization that leads to suitable Jacobians in the case of polynomial mappings. The properties of the semi-discrete scheme are verified and investigated using numerical experiments.

  15. Stable isotopes labelled compounds

    International Nuclear Information System (INIS)

    1982-09-01

    The catalogue on stable isotopes labelled compounds offers deuterium, nitrogen-15, and multiply labelled compounds. It includes: (1) conditions of sale and delivery, (2) the application of stable isotopes, (3) technical information, (4) product specifications, and (5) the complete delivery programme

  16. Stable Boundary Layer Issues

    NARCIS (Netherlands)

    Steeneveld, G.J.

    2012-01-01

    Understanding and prediction of the stable atmospheric boundary layer is a challenging task. Many physical processes are relevant in the stable boundary layer, i.e. turbulence, radiation, land surface coupling, orographic turbulent and gravity wave drag, and land surface heterogeneity. The

  17. SURGICAL REMOVAL OF EPIRETINAL MEMBRANE WITH AND WITHOUT REMOVAL OF INTERNAL LIMITING MEMBRANE: Comparative Study of Visual Acuity, Features of Optical Coherence Tomography, and Recurrence Rate.

    Science.gov (United States)

    De Novelli, Fernando J; Goldbaum, Mauro; Monteiro, Mario L R; Bom Aggio, Fabio; Takahashi, Walter Y

    2017-12-05

    To study and compare visual acuity, foveal thickness, outer limiting layer, ellipsoid zone, and recurrence rate in patients undergoing removal of the epiretinal membrane with and without the removal of the internal limiting membrane (ILM). Sixty-three patients who had the epiretinal membrane removed by a single surgeon were randomly assigned into 2 groups: Group 1 without additional removal of the ILM and Group 2 with removal of the ILM. Patients were followed up and evaluated at the first month, third month, and sixth month, postoperatively. Patients from both groups had a gradual improvement in their vision over time. There was no significant difference in the improvement in visual acuity between the two groups. About tomographic assessment of alterations, no significant differences were found between the groups; however, Group 1 had a higher relapse rate (17%) compared with Group 2 (3.6%) (P = 0.09). Epiretinal membrane removal with and without ILM peeling shows similar functional and anatomical improvements, but the group in which the ILM was not removed seemed to have a higher recurrence rate.

  18. Tennessee's forest land area was stable 1999-2005 but early successional forest area declined

    Science.gov (United States)

    Christopher M. Oswalt

    2008-01-01

    A new analysis of the most recent (2005) annualized moving average data for Tennessee indicates that the area of forest land in the State remained stable between 1999 and 2005. Although trends in forest land area vary from region to region within the State, Tennessee neither lost nor gained forest land between 1999 and 2005. However, Tennessee had more than 2.5 times...

  19. Structure of acid-stable carmine.

    Science.gov (United States)

    Sugimoto, Naoki; Kawasaki, Yoko; Sato, Kyoko; Aoki, Hiromitsu; Ichi, Takahito; Koda, Takatoshi; Yamazaki, Takeshi; Maitani, Tamio

    2002-02-01

    Acid-stable carmine has recently been distributed in the U.S. market because of its good acid stability, but it is not permitted in Japan. We analyzed and determined the structure of the major pigment in acid-stable carmine, in order to establish an analytical method for it. Carminic acid was transformed into a different type of pigment, named acid-stable carmine, through amination when heated in ammonia solution. The features of the structure were clarified using a model compound, purpurin, in which the orientation of hydroxyl groups on the A ring of the anthraquinone skeleton is the same as that of carminic acid. By spectroscopic means and the synthesis of acid-stable carmine and purpurin derivatives, the structure of the major pigment in acid-stable carmine was established as 4-aminocarminic acid, a novel compound.

  20. Uncorrected visual acuity in the immediate postoperative period following uncomplicated cataract surgery: bimanual microincision cataract surgery versus standard coaxial phacoemulsification.

    LENUS (Irish Health Repository)

    Saeed, Ayman

    2012-02-01

    AIM: We compared bimanual microincision cataract surgery (MICS) and standard coaxial phacoemulsification (CAP) in terms of uncorrected visual acuity (UCVA) recorded 1 h and 2 weeks postoperatively. METHODS: This was a prospective, nonrandomised comparative study. All MICS procedures were performed by one surgeon (MGM), and all CAP procedures were performed by another surgeon (SB). Eyes with visually consequential ocular morbidity were excluded. The primary outcome measure was UCVA recorded 1 h postoperatively. RESULTS: One hundred eyes underwent MICS and CAP (50 eyes in each group). The treatment groups did not differ significantly in terms of preoperative mean best corrected visual acuity (6\\/24 +\\/- 4.3 lines and 6\\/20 +\\/- 4.4 lines in the MICS and the CAP groups, respectively; P = 0.65). Also, there was no significant difference in terms of postoperative UCVA at 1 h or at 2 weeks (mean +\\/- standard deviation UCVA 1 h postoperatively: MICS: 6\\/36 +\\/- 5.7 lines; CAP: 6\\/30 +\\/- 4.7 lines; P = 0.80; UCVA 2 weeks postoperatively: MICS: 6\\/10 +\\/- 1.9 lines; CAP: 6\\/10 +\\/- 2.2 lines; P = 0.90). However, nine eyes (18%) and one eye (2%) achieved a UCVA of C6\\/12 at 1 h following MICS and CAP, respectively, and this difference was statistically significant (P = 0.02). CONCLUSION: Mean UCVA at 1 h and at 2 weeks following cataract surgery was not significantly different between eyes undergoing MICS and CAP. However, a greater proportion of patients achieved a UCVA of C6\\/12 following MICS when compared with CAP.

  1. Applications of stable isotopes

    International Nuclear Information System (INIS)

    Letolle, R.; Mariotti, A.; Bariac, T.

    1991-06-01

    This report reviews the historical background and the properties of stable isotopes, the methods used for their measurement (mass spectrometry and others), the present technics for isotope enrichment and separation, and at last the various present and foreseeable application (in nuclear energy, physical and chemical research, materials industry and research; tracing in industrial, medical and agronomical tests; the use of natural isotope variations for environmental studies, agronomy, natural resources appraising: water, minerals, energy). Some new possibilities in the use of stable isotope are offered. A last chapter gives the present state and forecast development of stable isotope uses in France and Europe

  2. A stable demand for money despite financial crisis: The case of Venezuela

    OpenAIRE

    Bjørnland, Hilde C.

    2003-01-01

    This paper investigates the demand for broad money in Venezuela, over a period of financial crisis and substantial exchange rate fluctuations. The analysis shows that there exist a long run relationship between real money, real income, inflation, the exchange rate and the domestic interest rate, that remains stable over major policy changes and large shocks. The long run properties emphasize that both inflation and exchange rate depreciations have negative effects on real money demand. The lo...

  3. Stable water use efficiency under climate change of three sympatric conifer species at the Alpine treeline

    Directory of Open Access Journals (Sweden)

    Gerhard eWieser

    2016-06-01

    Full Text Available The ability of treeline associated conifers in the Central Alps to cope with recent climate warming and increasing CO2 concentration is still poorly understood. We determined tree ring stable carbon and oxygen isotope ratios of Pinus cembra, Picea abies and Larix decidua trees from 1975-2010. Stable isotope ratios were compared with leaf level gas exchange measurements carried out in situ between 1979 and 2007. Results indicate that tree ring derived intrinsic water-use efficiency (iWUE of P. cembra, P. abies and L. decidua remained constant during the last 36 years despite climate warming and rising atmospheric CO2. Temporal patterns in Δ13C and Δ18O mirrored leaf level gas exchange assessments, suggesting parallel increases of CO2-fixation and stomatal conductance of treeline conifer species. As at the study site soil water availability was not a limiting factor iWUE remained largely stable throughout the study period. The stability in iWUE was accompanied by an increase in basal area increment (BAI suggesting that treeline trees benefit from both recent climate warming and CO2 fertilization. Finally, our results suggest that iWUE may not change species composition at treeline in the Austrian Alps due to similar ecophysiological responses to climatic changes of the three sympatric study species.

  4. Structurally stable graphene oxide-based nanofiltration membranes with bioadhesive polydopamine coating

    Science.gov (United States)

    Wang, Chongbin; Li, Zhiyuan; Chen, Jianxin; Yin, Yongheng; Wu, Hong

    2018-01-01

    Graphene oxide (GO)-based membranes possess promising potential in liquid separation for its high flux. The state-of-art GO-based membranes need to be supported by a substrate to ensure that the ultra-thin GO layer can withstand transmembrane pressure in practical applications. The interfacial compatibility of this kind of composite membrane remains a great challenge due to the intrinsic difference in chemical/physical properties between the GO sheets and the substrate. In this paper, a structurally stable GO-based composite nanofiltration membrane was fabricated by coupling the mussel-inspired adhesive platform and filtration-assisted assembly of GO laminates. The water flux for the prepared GO-based nanofiltration membrane reached up to 85 L m-2 h-1 bar-1 with a high retention above 95% and 100% for Orange G and Congo Red, respectively. The membrane exhibited highly stable structure owing to the covalent and noncovalent interactions between GO separation layer and dopamine adhesive platform.

  5. Tracking ENSO with tropical trees: Progress in stable isotope dendroclimatology

    Science.gov (United States)

    Evans, M. N.; Poussart, P. F.; Saleska, S. R.; Schrag, D. P.

    2002-12-01

    The terrestrial tropics remain an important gap in the growing proxy network used to characterize past ENSO behavior. Here we describe a strategy for development of proxy estimates of paleo-ENSO, via proxy rainfall estimates derived from stable isotope (δ18O) measurements made on tropical trees. The approach applies a new model of oxygen isotopic composition of alpha-cellulose (Roden et al., 2000), a rapid method for cellulose extraction from raw wood (Brendel et al., 2000), and continuous flow isotope ratio mass spectrometry (Brand, 1996) to develop proxy chronological, rainfall and growth rate estimates from tropical trees, even those lacking annual rings. The promise and pitfalls of the approach are illustrated in pilot datasets from the US, Costa Rica, Brazil, and Peru, which show isotopic cycles of 4-6 per mil, and interannual anomalies of up to 8 per mil. Together with the mature ENSO proxies (corals, extratropical tree-rings, varved sediments, and ice cores), replicated and well-dated stable isotope chronologies from tropical trees may eventually improve our understanding of ENSO history over the past several hundred years.

  6. Effects of constant immigration on the dynamics and persistence of stable and unstable Drosophila populations

    Science.gov (United States)

    Dey, Snigdhadip; Joshi, Amitabh

    2013-01-01

    Constant immigration can stabilize population size fluctuations but its effects on extinction remain unexplored. We show that constant immigration significantly reduced extinction in fruitfly populations with relatively stable or unstable dynamics. In unstable populations with oscillations of amplitude around 1.5 times the mean population size, persistence and constancy were unrelated. Low immigration enhanced persistence without affecting constancy whereas high immigration increased constancy without enhancing persistence. In relatively stable populations with erratic fluctuations of amplitude close to the mean population size, both low and high immigration enhanced persistence. In these populations, the amplitude of fluctuations relative to mean population size went down due to immigration, and their dynamics were altered to low-period cycles. The effects of immigration on the population size distribution and intrinsic dynamics of stable versus unstable populations differed considerably, suggesting that the mechanisms by which immigration reduced extinction risk depended on underlying dynamics in complex ways. PMID:23470546

  7. Population Games, Stable Games, and Passivity

    Directory of Open Access Journals (Sweden)

    Michael J. Fox

    2013-10-01

    Full Text Available The class of “stable games”, introduced by Hofbauer and Sandholm in 2009, has the attractive property of admitting global convergence to equilibria under many evolutionary dynamics. We show that stable games can be identified as a special case of the feedback-system-theoretic notion of a “passive” dynamical system. Motivated by this observation, we develop a notion of passivity for evolutionary dynamics that complements the definition of the class of stable games. Since interconnections of passive dynamical systems exhibit stable behavior, we can make conclusions about passive evolutionary dynamics coupled with stable games. We show how established evolutionary dynamics qualify as passive dynamical systems. Moreover, we exploit the flexibility of the definition of passive dynamical systems to analyze generalizations of stable games and evolutionary dynamics that include forecasting heuristics as well as certain games with memory.

  8. Diabetic macular oedema treated with intravitreal anti-vascular endothelial growth factor - 2-4 years follow-up of visual acuity and retinal thickness in 566 patients following Danish national guidelines

    DEFF Research Database (Denmark)

    Hodzic-Hadzibegovic, Delila; Sander, Birgit Agnes; Monberg, Tine Juul

    2017-01-01

    : Retrospective cohort study of 566 eyes in 566 patients with centre-involved DME who started intravitreal treatment with ranibizumab between January 2011 and December 2013 in the Greater Copenhagen region. Data were retrieved from a database and patient records between January 2011 and March 2016 and analysed...... using mixed-model statistics. Results: At the conclusion of follow-up, 24.6% were in active ranibizumab follow-up, 25.4% had switched to other intravitreal pharmacotherapy, 31.6% had been discontinued because of disease stability, 13.8% had been lost to follow-up, 1.4% had been discontinued because...... of low visual acuity (VA), and 3.2% had died. At baseline, mean best-corrected visual acuity (BCVA) and mean central subfield thickness (CST) were 64.9 (±15.0) letters and 400.2 (±120.3) μm. Mean change in BCVA and mean change in CST from baseline to 3, 12, 24, 36 and 48 months of follow-up were +3.9, +3...

  9. Correlation between observation task performance and visual acuity, contrast sensitivity and environmental light in a simulated maritime study.

    Science.gov (United States)

    Koefoed, Vilhelm F; Assmuss, Jörg; Høvding, Gunnar

    2018-03-25

    To examine the relevance of visual acuity (VA) and index of contrast sensitivity (ICS) as predictors for visual observation task performance in a maritime environment. Sixty naval cadets were recruited to a study on observation tasks in a simulated maritime environment under three different light settings. Their ICS were computed based on contrast sensitivity (CS) data recorded by Optec 6500 and CSV-1000E CS tests. The correlation between object identification distance and VA/ICS was examined by stepwise linear regression. The object detection distance was significantly correlated to the level of environmental light (p maritime environment may presumably be ascribed to the normal and uniform visual capacity in all our study subjects. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Visual stimulus parameters seriously compromise the measurement of approximate number system acuity and comparative effects between adults and children

    Directory of Open Access Journals (Sweden)

    Denes eSzucs

    2013-07-01

    Full Text Available It has been suggested that a simple non-symbolic magnitude comparison task is sufficient to measure the acuity of a putative Approximate Number System (ANS. A proposed measure of the ANS, the so-called 'internal Weber fraction' (w, would provide a clear measure of ANS acuity. However, ANS studies have never presented adequate evidence that the visual stimulus parameters did not compromise measurements of w to such extent that w is actually driven by visual instead of numerical processes. We therefore investigated this question by testing non-symbolic magnitude discrimination in seven-year-old children and adults. We controlled for visual parameters in a more stringent manner than usual. As a consequence of these controls, in some trials numerical cues correlated positively with number while in others they correlated negatively with number. This congruency effect strongly correlated with w, which means that congruency effects were probably driving effects in w. Consequently, in both adults and children congruency had a major impact on the fit of the model underlying the computation of w. Furthermore, children showed larger congruency effects than adults. This suggests that ANS tasks are seriously compromised by the visual stimulus parameters, which cannot be controlled. Hence, they are not pure measures of the ANS and some putative w or ratio effect differences between children and adults in previous ANS studies may be due to the differential influence of the visual stimulus parameters in children and adults. In addition, because the resolution of congruency effects relies on inhibitory (interference suppression function, some previous ANS findings were probably influenced by the developmental state of inhibitory processes especially when comparing children with developmental dyscalculia and typically developing children.

  11. [PALEOPATHOLOGY OF HUMAN REMAINS].

    Science.gov (United States)

    Minozzi, Simona; Fornaciari, Gino

    2015-01-01

    Many diseases induce alterations in the human skeleton, leaving traces of their presence in ancient remains. Paleopathological examination of human remains not only allows the study of the history and evolution of the disease, but also the reconstruction of health conditions in the past populations. This paper describes the most interesting diseases observed in skeletal samples from the Roman Imperial Age necropoles found in urban and suburban areas of Rome during archaeological excavations in the last decades. The diseases observed were grouped into the following categories: articular diseases, traumas, infections, metabolic or nutritional diseases, congenital diseases and tumours, and some examples are reported for each group. Although extensive epidemiological investigation in ancient skeletal records is impossible, the palaeopathological study allowed to highlight the spread of numerous illnesses, many of which can be related to the life and health conditions of the Roman population.

  12. Prediction of the remaining lifetime of stainless steels under conditions of stress corrosion cracking

    International Nuclear Information System (INIS)

    Tandler, M.; Vehovar, L.; Dolecek, V.; Rotnik, U.

    2003-01-01

    The prediction of the lifetime of metal structures and equipment under conditions of stress corrosion is very complicated because of the complexity of this process of degradation. Recently a new method, based on the so-called corrosion elongation curves, has been found, which can be used to predict the time to failure under these conditions. By upgrading of these curves (and thus obtaining Upgraded Corrosion Elongation Curves - UCEC's) it has been possible to obtain a precise definition of the time needed for the initiation of the corrosion crack, and for its stable growth. It is upon this basis that diagrams for the prediction of remaining lifetime (DPRL's) have been developed. DPRL's can also be used to predict the values of various critical parameters which have to be achieved if a stress corrosion crack is to occur. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [de

  13. New developments in the use of stable activable tracers in environmental science

    International Nuclear Information System (INIS)

    Loveland, W.; Keasler, K.; Ghannam, L.; Borovik, A.

    1980-01-01

    Recent developments in the use of stable activable tracers (SATs) in environmental science are reported. (A stable activable tracer is a stable material injected into a system under study and whose concentration is measured by post-sampling activation analysis.) The activable nuclear parts of the tracers studied have been rare earth nuclides with short-lived activation products or Cu. To trace the fate of fluid-bound pollutants (and/or water masses) in marine waters, we have used anionic DTPA complexes of the rare earths. These tracers were shown to be stable (80 to 90% nondissociated) in extensive laboratory tests involving solutions of the tracer in estuarine water including large amounts of marine sediments. Results of a field study in which the flushing time and other hydrological characteristics of an estuarine marina were measured by simultaneously using a fluorescent dye and a SAT are presented. To trace the path of potentially toxic organic molecules, three stable activable tracers, dysprosium(III)-trisacetylacetonate DY(acac) 3 3H 2 O), dysprosium(III)-trisdibenzoylmethane (DY(dbm) 3 H 2 O and copper oxinate Cu (C 9 H 6 ON) 2 were synthesized. Their octanol/water partition coefficients and their solubility in water were measured and used to correlate the tracer species and its biological activity with that of known toxic materials. In a project to demonstrate the simple use of SATs to trace the origin of common insecticides and herbicides, seven common insecticides and herbicides were marked with anionic rare earth DTPA complexes and shown to be detectable at dilutions of 1 part in 10 12 . Two arsenical herbicides were chosen for further study and the tracer/herbicide ratio was shown to remain constant in samples of herbicide material collected on plant surfaces and runoff waters in the environment for long periods

  14. Changes in visual acuity in patients with malignant melanoma of the uvea treated with stereotactic radiosurgery (presentation)

    International Nuclear Information System (INIS)

    Mackova, K.; Waczultkova, I.; Furdova, Ad.; Furdova, Al.

    2013-01-01

    The goal was to assess the changes in visual acuity before and after 6 months of treatment, depending on the dose in risk structures (lens, optic nerve). This is a retrospective study of 19 patients group treated in 2011. The average age of the group was (57.3 ± 12.4) years (31-73 years). The analysis of the studied group did not demonstrate dependence of the tumour presence on gender. Higher prevalence of tumours was observed in the elderly population. Considered relationship of worse diagnosis with higher age (r = 0.39; p = 0.13) we could not prove to be significant due to the small group of patients. The median of melanoma volume was 0.77 cm 3 (0.11 to 1.76 cubic centimetres). The mean dose applied to melanoma was 37.34 Gy (Gy 36.74 to 44.65).

  15. Metformin Impairs Spatial Memory and Visual Acuity in Old Male Mice.

    Science.gov (United States)

    Thangthaeng, Nopporn; Rutledge, Margaret; Wong, Jessica M; Vann, Philip H; Forster, Michael J; Sumien, Nathalie

    2017-02-01

    Metformin is an oral anti-diabetic used as first-line therapy for type 2 diabetes. Because benefits of metformin extend beyond diabetes to other age-related pathology, and because its effect on gene expression profiles resembles that of caloric restriction, metformin has a potential as an anti-aging intervention and may soon be assessed as an intervention to extend healthspan. However, beneficial actions of metformin in the central nervous system have not been clearly established. The current study examined the effect of chronic oral metformin treatment on motor and cognitive function when initiated in young, middle-aged, or old male mice. C57BL/6 mice aged 4, 11, or 22 months were randomly assigned to either a metformin group (2 mg/ml in drinking water) or a control group. The mice were monitored weekly for body weight, as well as food and water intake and a battery of behavioral tests for motor, cognitive and visual function was initiated after the first month of treatment. Liver, hippocampus and cortex were collected at the end of the study to assess redox homeostasis. Overall, metformin supplementation in male mice failed to affect blood glucose, body weights and redox homeostasis at any age. It also had no beneficial effect on age-related declines in psychomotor, cognitive or sensory functions. However, metformin treatment had a deleterious effect on spatial memory and visual acuity, and reduced SOD activity in brain regions. These data confirm that metformin treatment may be associated with deleterious effect resulting from the action of metformin on the central nervous system.

  16. CLINICAL STUDY OF POSTERIOR CHAMBER PHAKIC IOL PLACEMENT IN MYOPIC PATIENTS

    Directory of Open Access Journals (Sweden)

    Ashok Kumar P

    2017-02-01

    Full Text Available BACKGROUND The aim of this study was to determine the safety and efficacy of posterior chamber phakic IOL in Myopic patients. MATERIALS AND METHODS This prospective interventional study included 50 eyes of 50 patients with myopia. Patients of age more than 18 yrs. Stable refraction, Myopia, Mild to Moderate keratoconus and absence of any ocular pathology and any history of ocular surgeries were included in this study. Prior to starting treatment certain parameters like visual acuity, AC depth, Iridocorneal Angle Aperture, Endothelial cell count, Central corneal thickness and IOP were considered. Intervention- Implantation of the phakic IOL. Main outcome Measures- Uncorrected Visual Acuity (UCVA, best spectacle corrected visual acuity (BSCVA, AS OCT AC depthbetween endothelium and phakic IOL, IOP and Endothelial cell count were recorded. RESULTS Postoperative examinations conducted at day 1, day 3, after 1 week, 1 month and after 3 months .out of 50 patients, 4 patients had striate keratopathy, 2 patients had shallow ac during immediate post-operative period. During the postoperative follow up 10 patients had BCVA of 6/9-6/6 (20%, 14 patients had 6/9-6/12 (28%, 24 patients had 6/12-6/24(48% and remaining 2 patients had <6/24 which was better than their preoperative uncorrected visual acuity. CONCLUSION Based on this prospective clinical study and on comparison with other clinical studies posterior chamber phakic IOL corrective procedures are safe and effective for treatment of myopia. It also shows that it can provide sharp and clear vision in 96% of our study population. It does not induce dry eye syndrome as in other refractive surgeries. Short term complications like endothelial damage, angle closure glaucoma, iritis, anterior capsule injury/lens changes were not encountered during our study. But still long term follow up is required to confirm long term safety of the implant.

  17. Clinical manifestations of optic pit maculopathy as demonstrated by spectral domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Tzu JH

    2013-01-01

    Full Text Available Jonathan H Tzu, Harry W Flynn Jr, Audina M Berrocal, William E Smiddy, Timothy G Murray, Yale L FisherDepartment of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USAPurpose: The purpose of this retrospective study was to evaluate the characteristic features, including spectral-domain optical coherence tomography (SD-OCT, clinical course, and outcome of treatment if given for patients with optic disc pit maculopathy.Methods: We investigated a consecutive series of patients with a diagnosis of optic pit maculopathy treated between 2001 and 2012 at the Bascom Palmer Eye Institute. Patients were divided into two main groups, ie, patients who were observed without surgery and patients who received surgical intervention. The main outcome measures were presenting and final visual acuity, and changes in SD-OCT imaging were recorded. Other data including age, gender, eye, age of onset, length of follow-up, location of optic pit, and location of fluid by OCT were also recorded.Results: On OCT, 67% (12/18 of the eyes showed schisis-like cavities, 22% (4/18 had only subretinal fluid, and 17% (3/18 had only a schisis-like cavity without subretinal fluid. In the patients managed by observation, visual acuity was ≥20/200 in 6/8 eyes initially and 6/8 eyes at last follow-up. Ten of 18 patients received either focal laser, surgery or both. Six of 10 eyes undergoing surgery had initial visual acuity ≥ 20/200, and 8 of 10 eyes undergoing surgery had a visual acuity of ≥20/200 at last follow-up.Conclusion: In this study, many eyes were observed and remained stable during follow-up. In eyes with reduced vision, surgical intervention produced variable outcomes, and persistent intraretinal/subretinal fluid was a common occurrence.Keywords: optic pit maculopathy, spectral-domain optical coherence tomography

  18. Stable particles

    International Nuclear Information System (INIS)

    Samios, N.P.

    1993-01-01

    I have been asked to review the subject of stable particles, essentially the particles that eventually comprised the meson and baryon octets. with a few more additions -- with an emphasis on the contributions made by experiments utilizing the bubble chamber technique. In this activity, much work had been done by the photographic emulsion technique and cloud chambers-exposed to cosmic rays as well as accelerator based beams. In fact, many if not most of the stable particles were found by these latter two techniques, however, the forte of the bubble chamber (coupled with the newer and more powerful accelerators) was to verify, and reinforce with large statistics, the existence of these states, to find some of the more difficult ones, mainly neutrals and further to elucidate their properties, i.e., spin, parity, lifetimes, decay parameters, etc

  19. Influence of horse stable environment on human airways

    Directory of Open Access Journals (Sweden)

    Pringle John

    2009-05-01

    Full Text Available Abstract Background Many people spend considerable amount of time each day in equine stable environments either as employees in the care and training of horses or in leisure activity. However, there are few studies available on how the stable environment affects human airways. This study examined in one horse stable qualitative differences in indoor air during winter and late summer conditions and assessed whether air quality was associated with clinically detectable respiratory signs or alterations to selected biomarkers of inflammation and lung function in stable personnel. Methods The horse stable environment and stable-workers (n = 13 in one stable were investigated three times; first in the winter, second in the interjacent late summer and the third time in the following winter stabling period. The stable measurements included levels of ammonia, hydrogen sulphide, total and respirable dust, airborne horse allergen, microorganisms, endotoxin and glucan. The stable-workers completed a questionnaire on respiratory symptoms, underwent nasal lavage with subsequent analysis of inflammation markers, and performed repeated measurements of pulmonary function. Results Measurements in the horse stable showed low organic dust levels and high horse allergen levels. Increased viable level of fungi in the air indicated a growing source in the stable. Air particle load as well as 1,3-β-glucan was higher at the two winter time-points, whereas endotoxin levels were higher at the summer time-point. Two stable-workers showed signs of bronchial obstruction with increased PEF-variability, increased inflammation biomarkers relating to reported allergy, cold or smoking and reported partly work-related symptoms. Furthermore, two other stable-workers reported work-related airway symptoms, of which one had doctor's diagnosed asthma which was well treated. Conclusion Biomarkers involved in the development of airway diseases have been studied in relation to

  20. Influence of horse stable environment on human airways.

    Science.gov (United States)

    Elfman, Lena; Riihimäki, Miia; Pringle, John; Wålinder, Robert

    2009-05-25

    Many people spend considerable amount of time each day in equine stable environments either as employees in the care and training of horses or in leisure activity. However, there are few studies available on how the stable environment affects human airways. This study examined in one horse stable qualitative differences in indoor air during winter and late summer conditions and assessed whether air quality was associated with clinically detectable respiratory signs or alterations to selected biomarkers of inflammation and lung function in stable personnel. The horse stable environment and stable-workers (n = 13) in one stable were investigated three times; first in the winter, second in the interjacent late summer and the third time in the following winter stabling period. The stable measurements included levels of ammonia, hydrogen sulphide, total and respirable dust, airborne horse allergen, microorganisms, endotoxin and glucan. The stable-workers completed a questionnaire on respiratory symptoms, underwent nasal lavage with subsequent analysis of inflammation markers, and performed repeated measurements of pulmonary function. Measurements in the horse stable showed low organic dust levels and high horse allergen levels. Increased viable level of fungi in the air indicated a growing source in the stable. Air particle load as well as 1,3-beta-glucan was higher at the two winter time-points, whereas endotoxin levels were higher at the summer time-point. Two stable-workers showed signs of bronchial obstruction with increased PEF-variability, increased inflammation biomarkers relating to reported allergy, cold or smoking and reported partly work-related symptoms. Furthermore, two other stable-workers reported work-related airway symptoms, of which one had doctor's diagnosed asthma which was well treated. Biomarkers involved in the development of airway diseases have been studied in relation to environmental exposure levels in equine stables. Respirable dust and 1

  1. Stable configurations in social networks

    Science.gov (United States)

    Bronski, Jared C.; DeVille, Lee; Ferguson, Timothy; Livesay, Michael

    2018-06-01

    We present and analyze a model of opinion formation on an arbitrary network whose dynamics comes from a global energy function. We study the global and local minimizers of this energy, which we call stable opinion configurations, and describe the global minimizers under certain assumptions on the friendship graph. We show a surprising result that the number of stable configurations is not necessarily monotone in the strength of connection in the social network, i.e. the model sometimes supports more stable configurations when the interpersonal connections are made stronger.

  2. Development of Stable Isotope Technology

    International Nuclear Information System (INIS)

    Jeong, Do Young; Kim, Cheol Jung; Han, Jae Min

    2009-03-01

    KAERI has obtained an advanced technology with singular originality for laser stable isotope separation. Objectives for this project are to get production technology of Tl-203 stable isotope used for medical application and are to establish the foundation of the pilot system, while we are taking aim at 'Laser Isotope Separation Technology to make resistance to the nuclear proliferation'. And we will contribute to ensuring a nuclear transparency in the world society by taking part in a practical group of NSG and being collaboration with various international groups related to stable isotope separation technology

  3. Calcium stable isotope geochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Gausonne, Nikolaus [Muenster Univ. (Germany). Inst. fuer Mineralogie; Schmitt, Anne-Desiree [Strasbourg Univ. (France). LHyGeS/EOST; Heuser, Alexander [Bonn Univ. (Germany). Steinmann-Inst. fuer Geologie, Mineralogie und Palaeontologie; Wombacher, Frank [Koeln Univ. (Germany). Inst. fuer Geologie und Mineralogie; Dietzel, Martin [Technische Univ. Graz (Austria). Inst. fuer Angewandte Geowissenschaften; Tipper, Edward [Cambridge Univ. (United Kingdom). Dept. of Earth Sciences; Schiller, Martin [Copenhagen Univ. (Denmark). Natural History Museum of Denmark

    2016-08-01

    This book provides an overview of the fundamentals and reference values for Ca stable isotope research, as well as current analytical methodologies including detailed instructions for sample preparation and isotope analysis. As such, it introduces readers to the different fields of application, including low-temperature mineral precipitation and biomineralisation, Earth surface processes and global cycling, high-temperature processes and cosmochemistry, and lastly human studies and biomedical applications. The current state of the art in these major areas is discussed, and open questions and possible future directions are identified. In terms of its depth and coverage, the current work extends and complements the previous reviews of Ca stable isotope geochemistry, addressing the needs of graduate students and advanced researchers who want to familiarize themselves with Ca stable isotope research.

  4. Calcium stable isotope geochemistry

    International Nuclear Information System (INIS)

    Gausonne, Nikolaus; Schmitt, Anne-Desiree; Heuser, Alexander; Wombacher, Frank; Dietzel, Martin; Tipper, Edward; Schiller, Martin

    2016-01-01

    This book provides an overview of the fundamentals and reference values for Ca stable isotope research, as well as current analytical methodologies including detailed instructions for sample preparation and isotope analysis. As such, it introduces readers to the different fields of application, including low-temperature mineral precipitation and biomineralisation, Earth surface processes and global cycling, high-temperature processes and cosmochemistry, and lastly human studies and biomedical applications. The current state of the art in these major areas is discussed, and open questions and possible future directions are identified. In terms of its depth and coverage, the current work extends and complements the previous reviews of Ca stable isotope geochemistry, addressing the needs of graduate students and advanced researchers who want to familiarize themselves with Ca stable isotope research.

  5. National uses and needs for separated stable isotopes in physics, chemistry, and geoscience research

    International Nuclear Information System (INIS)

    Zisman, M.S.

    1982-01-01

    Present uses of separated stable isotopes in the fields of physics, chemistry, and the geosciences have been surveyed to identify current supply problems and to determine future needs. Demand for separated isotopes remains strong, with 220 different nuclides having been used in the past three years. The largest needs, in terms of both quantity and variety of isotopes, are found in nuclear physics research. Current problems include a lack of availability of many nuclides, unsatisfactory enrichment of rare species, and prohibitively high costs for certain important isotopes. It is expected that demands for separated isotopes will remain roughly at present levels, although there will be a shift toward more requests for highly enriched rare isotopes. Significantly greater use will be made of neutron-rich nuclides below A = 100 for producing exotic ion beams at various accelerators. Use of transition metal nuclei for nuclear magnetic resonance spectroscopy will expand. In addition, calibration standards will be required for the newer techniques of radiological dating, such as the Sm/Nd and Lu/Hf methods, but in relatively small quantities. Most members of the research community would be willing to pay considerably more than they do now to maintain adequate supplies of stable isotopes

  6. National uses and needs for separated stable isotopes in physics, chemistry, and geoscience research

    Energy Technology Data Exchange (ETDEWEB)

    Zisman, M.S.

    1982-01-01

    Present uses of separated stable isotopes in the fields of physics, chemistry, and the geosciences have been surveyed to identify current supply problems and to determine future needs. Demand for separated isotopes remains strong, with 220 different nuclides having been used in the past three years. The largest needs, in terms of both quantity and variety of isotopes, are found in nuclear physics research. Current problems include a lack of availability of many nuclides, unsatisfactory enrichment of rare species, and prohibitively high costs for certain important isotopes. It is expected that demands for separated isotopes will remain roughly at present levels, although there will be a shift toward more requests for highly enriched rare isotopes. Significantly greater use will be made of neutron-rich nuclides below A = 100 for producing exotic ion beams at various accelerators. Use of transition metal nuclei for nuclear magnetic resonance spectroscopy will expand. In addition, calibration standards will be required for the newer techniques of radiological dating, such as the Sm/Nd and Lu/Hf methods, but in relatively small quantities. Most members of the research community would be willing to pay considerably more than they do now to maintain adequate supplies of stable isotopes.

  7. Tactile perception in blind Braille readers: a psychophysical study of acuity and hyperacuity using gratings and dot patterns.

    Science.gov (United States)

    Grant, A C; Thiagarajah, M C; Sathian, K

    2000-02-01

    It is not clear whether the blind are generally superior to the sighted on measures of tactile sensitivity or whether they excel only on certain tests owing to the specifics of their tactile experience. We compared the discrimination performance of blind Braille readers and age-matched sighted subjects on three tactile tasks using precisely specified stimuli. Initially, the blind significantly outperformed the sighted at a hyperacuity task using Braille-like dot patterns, although, with practice, both groups performed equally well. On two other tasks, hyperacute discrimination of gratings that differed in ridge width and spatial-acuity-dependent discrimination of grating orientation, the performance of the blind did not differ significantly from that of sighted subjects. These results probably reflect the specificity of perceptual learning due to Braille-reading experience.

  8. Phase I/II study of proton beam irradiation for the treatment of subfoveal choroidal neovascularization in age-related macular degeneration: treatment techniques and preliminary results

    International Nuclear Information System (INIS)

    Yonemoto, Leslie T.; Slater, Jerry D.; Friedrichsen, Eric J.; Loredo, Lilia N.; Ing, Jeffrey; Archambeau, John O.; Teichman, Sandra; Moyers, Michael F.; Blacharski, Paul A.; Slater, James M.

    1996-01-01

    Purpose: Age-related macular degeneration is the prevalent etiology of subfoveal choroidal neovascularization (CNV). The only effective treatment is laser photocoagulation, which is associated with decreased visual acuity following treatment in most patients. This study assessed both the response of subfoveal CNV to proton beam irradiation and treatment-related morbidity. We evaluated preliminary results in patients treated with an initial dose of 8 Cobalt Gray Equivalents (CGE) using a relative biological effectiveness (RBE) of 1.1. Methods and Materials: Twenty-one patients with subfoveal CNV received proton irradiation to the central macula with a single fraction of 8 CGE; 19 were eligible for evaluation. Treatment-related morbidity was based on Radiation Therapy Oncology Group (RTOG) criteria; response was evaluated by Macular Photocoagulation Study (MPS) guidelines. Fluorescein angiography was performed; visual acuity, contrast sensitivity, and reading speed were measured at study entry and at 3-month intervals after treatment. Follow-up ranged from 6 to 15 months. Results: No measurable treatment-related morbidity was seen during or after treatment. Of 19 patients evaluated at 6 months, fluorescein angiography demonstrated treatment response in 10 (53%); 14 (74%) patients had improved or stable visual acuity. With a mean follow-up of 11.6 months, 11 (58%) patients have demonstrated improved or stable visual acuity. Conclusion: A macular dose of 8 CGE yielded no measurable treatment morbidity in patients studied. Fluorescein nagiography demonstrated that regressed or stabilized lesions were associated with improved visual acuity as compared with MPS results. In the next phase, a dose of 14 CGE in a single fraction will be used to further define the optimal dose fractionation schedule

  9. Visual Acuity Change over 12 Months in the Prospective Progression of Atrophy Secondary to Stargardt Disease (ProgStar) Study: ProgStar Report Number 6.

    Science.gov (United States)

    Kong, Xiangrong; Strauss, Rupert W; Cideciyan, Artur V; Michaelides, Michel; Sahel, José-Alain; Munoz, Beatriz; Ahmed, Mohamed; Ervin, Ann M; West, Sheila K; Cheetham, Janet K; Scholl, Hendrik P N

    2017-11-01

    To estimate the yearly rate of change of best-corrected visual acuity (BCVA) and the risk of loss 1 line or more over 1 year and to identify risk factors for BCVA loss in patients with Stargardt disease (STGD1). Multicenter, prospective cohort study. Two hundred fifty-nine patients (489 eyes) with molecularly confirmed STGD1 enrolled at 9 centers in the United States and Europe. Participants were followed up every 6 months, and data at the baseline and 6- and 12-month visits were analyzed. Best-corrected visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. Standardized reporting forms were used to collect participants' characteristics and clinical observations. Linear mixed effects models were used to estimate the rate of BCVA loss. Linear models with generalized estimating equations were used to identify risk factors for BCVA loss of 1 line or more over 1 year. Change in BCVA over 1 year. Cross-sectional analysis at baseline showed that earlier symptom onset and longer duration since onset was associated with worse BCVA. Longitudinal analysis showed no overall significant change of BCVA within 12 months, but the rate of BCVA change was significantly different by baseline BCVA (P trials with 1 year's duration. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Registered Nurse Staffing in Pennsylvania Nursing Homes: Comparison before and after Implementation of Medicare's Prospective Payment System.

    Science.gov (United States)

    Kanda, Katsuya; Mezey, Mathy

    1991-01-01

    Examined changes in resident acuity and registered nurse staffing in all nursing homes in Pennsylvania before and after introduction of Medicare Prospective Payment System (PPS) in 1983. Found that acuity of nursing home residents increased significantly since introduction of PPS, full-time registered nurse staffing remained unchanged, and…

  11. Topical tazarotene vs. coal tar in stable plaque psoriasis

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, U.; Kaur, I.; Dogra, S.; De, D.; Kumar, B. [Postgraduate Institute of Medical Education & Research, Chandigarh (India)

    2010-07-15

    The efficacy of topical tazarotene has not previously been compared with the conventional topical treatment of crude coal tar (CCT) in stable plaque psoriasis. In this nonblinded side-to-side comparison study, patients with chronic stable plaque psoriasis, who had bilaterally symmetrical plaques on the limbs, applied 0.1% tazarotene gel on the right side and 5% CCT ointment on the left side once daily for 12 weeks followed by an 8-week treatment-free follow up period. Severity of psoriatic lesions and response to treatment was evaluated by scoring erythema, scaling and induration (ESI). Of 30 patients recruited, 27 could be assessed. In the per-protocol analysis, the mean percentage reduction in ESI score at the end of the treatment period was 74.15% {+-} 9.43 and 77.37% {+-} 10.93 with tazarotene and CCT, respectively (P {gt} 0.05). A reduction in ESI score of {gt} 75% was seen in 11 (40.74%) and 16 (59.26%) patients with tazarotene and CCT, respectively, at the end of 12 weeks. Side-effects were seen in 48.14% of patients treated with tazarotene, but in no patient treated with CCT. Tazarotene 0.1% gel has comparable clinical efficacy to CCT 5% ointment. CCT ointment remains a cost-effective therapy for plaque psoriasis.

  12. Unpredictably Stable

    DEFF Research Database (Denmark)

    Failla, Virgilio; Melillo, Francesca; Reichstein, Toke

    2014-01-01

    Is entrepreneurship a more stable career choice for high employment turnover individuals? We find that a transition to entrepreneurship induces a shift towards stayer behavior and identify job matching, job satisfaction and lock-in effects as main drivers. These findings have major implications...

  13. The prevalence and causes of decreased visual acuity – a study based on vision screening conducted at Enukweni and Mzuzu Foundation Primary Schools, Malawi

    OpenAIRE

    Thom L; Jogessar S; McGowan SL; Lawless F

    2016-01-01

    Leaveson Thom,1 Sanchia Jogessar,1,2 Sara L McGowan,1 Fiona Lawless,1,2 1Department of Optometry, Mzuzu University, Mzuzu, Malawi; 2Brienholden Vision Institute, Durban, South Africa Aim: To determine the prevalence and causes of decreased visual acuity (VA) among pupils recruited in two primary schools in Mzimba district, northern region of Malawi.Materials and methods: The study was based on the vision screening which was conducted by optometrists at Enukweni and Mzuzu Foundation Primary Sc...

  14. The prevalence and causes of decreased visual acuity – a study based on vision screening conducted at Enukweni and Mzuzu Foundation Primary Schools, Malawi

    OpenAIRE

    Thom,Leaveson; Jogessar,Sanchia; McGowan,Sara L; Lawless,Fiona

    2016-01-01

    Leaveson Thom,1 Sanchia Jogessar,1,2 Sara L McGowan,1 Fiona Lawless,1,2 1Department of Optometry, Mzuzu University, Mzuzu, Malawi; 2Brienholden Vision Institute, Durban, South Africa Aim: To determine the prevalence and causes of decreased visual acuity (VA) among pupils recruited in two primary schools in Mzimba district, northern region of Malawi.Materials and methods: The study was based on the vision screening which was conducted by optometrists at Enukweni and Mzuzu Foundation Primary Sc...

  15. Mitomycin-augmented non-penetrating deep sclerectomy: preoperative gonioscopy and postoperative perimetric, tonometric and medication trends.

    Science.gov (United States)

    Sponsel, William Eric; Groth, Sylvia Linner

    2013-03-01

    Non-penetrating deep sclerectomy (NPDS) can enhance drainage of aqueous humour without disrupting the trabecular endothelial layer, reducing risks of postoperative hypotony and hyphema. This study explores associations of angle morphology with surgical efficacy in eyes with open and obstructed angles. Eighty-nine consecutive eyes undergoing successful NPDS (non-implant, with 0.4 mg/ml mitomycin C and limbus-based two-layer closure) were studied in this institutional review board-approved retrospective quality assurance study. Postoperative complication frequency, intraocular pressure (IOP), glaucoma medications required and acuity were monitored (baseline vs 3, 6, 9, 12 and 18-month postoperative levels), along with 30-2 Humphrey MD and corrected pattern standard deviation (CPSD) (baseline vs 6, 12 and 18-month postoperative values). Preoperative gonioscopy was compared with the subsequent requirement for specific postoperative interventions. IOP at all five postoperative intervals was reduced (22 ± 0.9 to 12 ± 0.5 mm Hg; p<0.0001). No hyphema were observed. Postoperative hypotony (IOP < 4 mm Hg) occurred rarely (8/445; 1.8%). Mean glaucoma medication use dropped from 3.1 ± 0.1 to 0.23 ± 0.1 at 18 months (p<0.0001). Mean 30-2 MD improved by approximately 1.4 dB at 6, 12 and 18 months (p<0.002); CPSD remained stable. Following NPDS, a sustained IOP decrease of 10 mm Hg (45%) was attained, with stable acuity, increased perimetric generalised light sensitivity and 90% reduction in medical therapy requirement. Morbidity risk was associated with narrow gonioscopic angle insertion and synechia, but not with shallow approach or trabecular pigmentation.

  16. The Effects of Ramadan Fasting on Anterior Segment Parameters, Visual Acuity and Intraocular Pressures of the Eye.

    Science.gov (United States)

    Selver, Ozlem Barut; Palamar, Melis; Gerceker, Kevser; Egrilmez, Sait; Yagci, Ayse

    2017-01-01

    It is aimed to determine whether fasting during Ramadan has any significant effect on anterior chamber parameters, visual acuity and intraocular pressures. 31 fasting (Group 1) and 30 non-fasting healthy volunteers (Group 2) were enrolled. All cases underwent an ophthalmological examination and anterior segment parameter evaluation (central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), pupil size) with Pentacam before and after the breaking of the Ramadan fast in Group 1, before and after dinner in Group 2. The mean age was 43.35 ± 13.20 in Group 1, 43.17 ± 12.90 in Group 2 (p= 0.955). No significant difference was detected in any of the parameters in both groups. There is a need for more detailed and associated studies to understand better about the influence of Ramadan fast on various ocular parameters.

  17. Visual Acuity in Orbital Floor Fractures: Does Surgical Subspecialty Management Matter?

    Science.gov (United States)

    Richards, Nikisha Q; Brown, Ninita H; Kidwell, Earl D R

    2015-07-01

    At the time of this writing, there is no consensus regarding orbital floor fracture (OFFx) management. Proper management of OFFxs is imperative to help prevent well known complications and the possibility of decreased visual acuity (VA). The VA outcomes have been largely underreported in the literature. The current study identifies the complications of the different subspecialty management including VA outcome. A retrospective chart review study was performed to identify patients who suffered an OFFx and were managed by ophthalmology alone or in conjunction with either ENT or oral maxillofacial surgery at a single hospital. The primary outcome included VA at injury and subsequent visits. Secondary outcomes included epiphora, diplopia, enophthalmos, infraorbital dysesthesia, and decreased motility. Data were analyzed using Microsoft Office Excel 2007 using the Student t-test to find a P value < 0.05. There were 54 patients with OFFx. The majority were Black (83.3%) and men (77.8%) with their average age at time of injury being 37.6 (SE = 17.02) years. The majority of OFFxs were secondary to assault (65%). The average follow-up was 2.84 (SE = 5.38) months. The 34 patients who did not undergo surgical correction had statistically significant improvement of their VA by 1 week after injury (P = 0.02). There was no statistically significant improvement in VA outcomes for surgical patients of ophthalmology (P = 0.45) or oral maxillofacial surgery (P = 0.12). Patients undergoing OFFx repair did not have improved VA. The VA of nonsurgical patients was statistically significantly improved by 1 week after injury (P = 0.02).

  18. From Advance Euthanasia Directive to Euthanasia: Stable Preference in Older People?

    Science.gov (United States)

    Bolt, Eva E; Pasman, H Roeline W; Deeg, Dorly J H; Onwuteaka-Philipsen, Bregje D

    2016-08-01

    To determine whether older people with advance directive for euthanasia (ADEs) are stable in their advance desire for euthanasia in the last years of life, how frequently older people with an ADE eventually request euthanasia, and what factors determine this. Mortality follow-back study nested in a cohort study. The Netherlands. Proxies of deceased members of a cohort representative of Dutch older people (n = 168) and a cohort of people with advance directives (n = 154). Data from cohort members (possession of ADE) combined with after-death proxy information on cohort members' last 3 months of life. Multiple logistic regression analysis was performed on determinants of a euthanasia request in individuals with an ADE. Response rate was 65%. One hundred forty-two cohort members had an ADE at baseline. Three months before death, 87% remained stable in their desire for euthanasia; 47% eventually requested euthanasia (vs 6% without an ADE), and 16% died after euthanasia. People with an ADE were more likely to request euthanasia if they worried about loss of dignity. The majority of older adults who complete an ADE will have a stable preference over time, but an advance desire for euthanasia does not necessarily result in a euthanasia request. Writing an ADE may reflect a person's need for reassurance that they can request euthanasia in the future. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  19. Alternative Stable States, Coral Reefs, and Smooth Dynamics with a Kick.

    Science.gov (United States)

    Ippolito, Stephen; Naudot, Vincent; Noonburg, Erik G

    2016-03-01

    We consider a computer simulation, which was found to be faithful to time series data for Caribbean coral reefs, and an analytical model to help understand the dynamics of the simulation. The analytical model is a system of ordinary differential equations (ODE), and the authors claim this model demonstrates the existence of alternative stable states. The existence of an alternative stable state should consider a sudden shift in coral and macroalgae populations, while the grazing rate remains constant. The results of such shifts, however, are often confounded by changes in grazing rate. Although the ODE suggest alternative stable states, the ODE need modification to explicitly account for shifts or discrete events such as hurricanes. The goal of this paper will be to study the simulation dynamics through a simplified analytical representation. We proceed by modifying the original analytical model through incorporating discrete changes into the ODE. We then analyze the resulting dynamics and their bifurcations with respect to changes in grazing rate and hurricane frequency. In particular, a "kick" enabling the ODE to consider impulse events is added. Beyond adding a "kick" we employ the grazing function that is suggested by the simulation. The extended model was fit to the simulation data to support its use and predicts the existence cycles depending nonlinearly on grazing rates and hurricane frequency. These cycles may bring new insights into consideration for reef health, restoration and dynamics.

  20. Stable isotopic variation in tropical forest plants for applications in primatology.

    Science.gov (United States)

    Blumenthal, Scott A; Rothman, Jessica M; Chritz, Kendra L; Cerling, Thure E

    2016-10-01

    Stable isotope analysis is a promising tool for investigating primate ecology although nuanced ecological applications remain challenging, in part due to the complex nature of isotopic variability in plant-animal systems. The aim of this study is to investigate sources of carbon and nitrogen isotopic variation at the base of primate food webs that reflect aspects of primate ecology. The majority of primates inhabit tropical forest ecosystems, which are dominated by C3 vegetation. We used stable isotope ratios in plants from Kibale National Park, Uganda, a well-studied closed-canopy tropical forest, to investigate sources of isotopic variation among C3 plants related to canopy stratification, leaf age, and plant part. Unpredictably, our results demonstrate that vertical stratification within the canopy does not explain carbon or nitrogen isotopic variation in leaves. Leaf age can be a significant source of isotopic variation, although the direction and magnitude of this difference is not consistent across tree species. Some plant parts are clearly differentiated in carbon and nitrogen isotopic composition, particularly leaves compared to non-photosynthetic parts such as reproductive parts and woody stem parts. Overall, variation in the isotopic composition of floral communities, plant species, and plant parts demonstrates that stable isotope studies must include analysis of local plant species and parts consumed by the primates under study from within the study area. Am. J. Primatol. 78:1041-1054, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  1. Stable rotating dipole solitons in nonlocal media

    DEFF Research Database (Denmark)

    Lopez-Aguayo, Servando; Skupin, Stefan; Desyatnikov, Anton S.

    2006-01-01

    We present the first example of stable rotating two-soliton bound states in nonlinear optical media with nonlocal response. We show that, in contrast to media with local response, nonlocality opens possibilities to generate stable azimuthons.......We present the first example of stable rotating two-soliton bound states in nonlinear optical media with nonlocal response. We show that, in contrast to media with local response, nonlocality opens possibilities to generate stable azimuthons....

  2. Efficient and stable single-dopant white OLEDs based on 9,10-bis (2-naphthyl) anthracene

    International Nuclear Information System (INIS)

    Tao Silu; Peng Zhaokuai; Zhang Xiaohong; Wu Shikang

    2006-01-01

    Efficient white organic light-emitting diodes (WOLEDs) are fabricated with a thin layer of 9,10-bis (2-naphthyl) anthracene (ADN) doped with Rubrene as the source of white emission. A device with the structure of ITO/NPB (70nm)/ADN: 0.5% Rubrene (30nm)/Alq 3 (50nm)/MgAg shows a maximum current efficiency of 3.7cd/A, with the CIE coordinates of x=0.33, y=0.43. The EL spectrum of the devices and the CIE coordinates remains almost the same when the voltage is increased from 10 to 15V and the current efficiency remains quite stable with the current density increased from 20 to 250mA/cm 2

  3. Tempered stable laws as random walk limits

    OpenAIRE

    Chakrabarty, Arijit; Meerschaert, Mark M.

    2010-01-01

    Stable laws can be tempered by modifying the L\\'evy measure to cool the probability of large jumps. Tempered stable laws retain their signature power law behavior at infinity, and infinite divisibility. This paper develops random walk models that converge to a tempered stable law under a triangular array scheme. Since tempered stable laws and processes are useful in statistical physics, these random walk models can provide a basic physical model for the underlying physical phenomena.

  4. Acuidade visual e eletrorretinografia de campo total em pacientes com síndrome de Usher Visual acuity and full-field electroretinography in patients with Usher's syndrome

    Directory of Open Access Journals (Sweden)

    Luana Mendieta

    2005-04-01

    and visual acuity (VA among patients with type I and II Usher's syndrome. METHODS: Electroretinography responses and visual acuity were studied in 22 patients (mean age at test = 26.8±16.8 years. Seventeen patients had SU type I and 5 patients were diagnosed as Usher's syndrome type II. RESULTS: Mean visual acuity was 0.9 logMAR (20/160, Snellen equivalent for patients with Usher's syndrome type I and 0.4 logMAR (20/50, Snellen equivalent for patients with Usher's syndrome type II. Scotopic rod and maximal responses were non-detectable in both groups. Mean amplitude for oscillatory potentials was 14.5 µV ±6.1 in Usher's syndrome type I and 12.6 µV±5.2 in Usher's syndrome type II. Cone responses were non-detectable in 95% of the patients with Usher's syndrome I and in 100% of patients with Usher's syndrome II. Mean amplitude for 30 Hz flicker photopic cone response was 3.1 µV±4.1 for Usher's syndrome type I and 1.0 µV±0.6 for type II with mean implicit time of 34.0 ms±6.2 (US I and 35.8 ms±3.1 (type II. CONCLUSIONS: Visual acuity was relatively preserved in both groups, however Usher's syndrome II group showed better visual acuity results. Electroretinography findings were severely reduced in both groups, with most patients showing non-detectable rod and cone responses.

  5. Chronic stable angina is associated with lower health-related quality of life: evidence from Chinese patients.

    Directory of Open Access Journals (Sweden)

    Jing Wu

    Full Text Available OBJECTIVES: To compare health-related quality of life (HRQoL between patients with stable angina and the general population in China and to examine factors associated with HRQoL among patients with stable angina. METHODS: A cross-sectional HRQoL survey of stable angina patients recruited from 4 hospitals (n = 411 and the general population recruited from 3 Physical Examination Centers (n = 549 was conducted from July to December, 2011 in two large cities, Tianjin and Chengdu. HRQoL was assessed using the EQ-5D, EQ-VAS, and SF-6D instruments. The health status specific to patients with stable angina was assessed using the Seattle Angina Questionnaire (SAQ. Information on socio-demographic, clinical, and lifestyle factors were also collected. Nested regressions were performed to explore how these factors were associated with HRQoL in patients with stable angina. RESULTS: Compared with the general population (44.2 ± 10 years, 49.9% females, stable angina patients (68.1 ± 12 years, 50.4% females had significantly lower HRQoL scores in EQ-5D utility index (0.75 ± 0.19 vs. 0.90 ± 0.20, p<0.05, SF-6D utility index (0.68 ± 0.12 vs. 0.85 ± 0.11, p<0.05, and EQ-VAS (71.2 ± 12.3 vs. 83.9 ± 10.9, p<0.05. The differences remained (-0.05 for EQ-5D, -9.27 for EQ-VAS and -0.13 for SF-6D after controlling for socio-economic characteristics. SAQ scores showed that stable angina patients experienced impaired disease-specific health status, especially in angina stability (40.5 ± 34.6. Nested regressions indicated stable angina-specific health status explained most of the variation in HRQoL, among which disease perception, physical limitation, and angina stability were the strongest predictors. More physical exercise and better sleep were positively related with HRQoL. CONCLUSIONS: Compared to the general population, stable angina patients were associated with lower HRQoL and lower health utility scores, which were largely impacted by clinical symptoms

  6. Immunosuppression Adherence in Stable Kidney Transplant Patients Converted From Immediate- to Prolonged-Release Tacrolimus in Clinical Practice: A Norwegian Study.

    Science.gov (United States)

    Abedini, Sadollah; Gøransson, Lasse; Cockburn, Elinor; Kilany, Suzanne; Holdaas, Hallvard

    2018-02-01

    This study investigated medication adherence in kidney transplant patients (KTPs) converted from immediate-release tacrolimus (IR-T) to prolonged-release tacrolimus (PR-T)-based immunosuppression in routine practice. Noninterventional, observational, multicenter study in Norway. Included adult KTPs with stable graft function, converted from IR-T (baseline) to PR-T (1 mg:1 mg) in routine practice. Data were collected at baseline, and months 1, 3, 6, and 12 postconversion. Primary endpoint: adherence using the Basel Assessment of Adherence to Immunosuppressive Medication Scale. Secondary assessments: tacrolimus dose and trough levels (target, 3-7 ng/mL), clinical laboratory parameters (eg, estimated glomerular filtration rate [Modified Diet in Renal Disease]), and adverse events. Ninety-one KTPs (mean ± SD age 47.7 ± 14.3 years) were analyzed. Mean ± SD change in PR-T dose from baseline (4.4 ± 2.4 mg/d) to month 12 was -0.1 ± 0.9 mg/d; mean tacrolimus trough levels remained within target. Overall medication adherence increased from 45.6% at baseline to 58.1% at month 1, but was similar to baseline thereafter; taking and timing adherence followed a similar pattern. Odds ratio (OR) for adherence at month 1 (but not at other time points) was greater versus baseline for overall (OR, 1.71; P = 0.0205), taking (OR, 3.38; P = 0.0004), and timing (OR, 1.77, P = 0.0252) dimensions. Mean ± SD Basel Assessment of Adherence to Immunosuppressive Medication Scale visual analogue scale score at baseline was 96.4 ± 5.5%, and increased postconversion. Estimated glomerular filtration rate remained stable (month 12, 61.6 ± 17.7 mL/min per 1.73 m 2 ), as did other laboratory parameters. Two (2.2%) patients had adverse events considered probably/possibly treatment-related. There was disparity between high, patient-perceived and low, actual adherence. Converting stable KTPs from IR-T to PR-T in routine practice did not impact long-term adherence to immunosuppression; renal

  7. Comparação entre acuidade visual e photoscreening como métodos de triagem visual para crianças em idade escolar Comparison between visual acuity and photoscreening used like visual screening methods for scholar aged children

    Directory of Open Access Journals (Sweden)

    Roberta Lílian Fernandes de Sousa

    2012-12-01

    Full Text Available OBJETIVO: Avaliar a sensibilidade do aparelho photoscreener na detecção de alterações oculares em crianças informantes, comparando os dados à acuidade visual obtida pela tabela E de Snellen. MÉTODOS: Foram avaliadas 500 crianças de idades entre 5 e 12 anos, de escola do município de Botucatu, estado de São Paulo. As crianças foram submetidas ao teste de acuidade visual pela tabela E de Snellen e foram fotografadas utilizando-se o aparelho photoscreenerTM system model MTI-PS100, seguindo-se a análise das fotos obtidas. RESULTADOS: Houve concordância negativa (criança com boa acuidade visual e teste negativo com o photoscreener em 81,0%; concordância positiva (acuidade visual alterada e teste positivo em 7,6% e não houve concordância de resultados em 11,0% dos casos. CONCLUSÃO: A avaliação comparativa entre o método da acuidade visual pela tabela E de Snellen e o photocreener para detecção de problemas visuais mostrou alta concordância. Os autores sugerem entretanto, a triagem usando tabelas de acuidade visual quando se trata de crianças informantes, devido aos custos com o aparelho.PURPOSE: To evaluate the sensitivity of the photoscreener equipment to detect ocular changes in informative children comparing with the data obtained by the E Snellen´s table. METHODS: We evaluated 500 children between 5 and 12 years old, from a school of Botucatu city, São Paulo state. The children were submitted to a visual acuity test using the Snellen´s E Table and were photographed with the photoscreenerTM system model MTI-PS100, following the photos' analyze. RESULTS: There were negative agreement (children with a good visual acuity and a negative test with the Photoscreener in 81.0%; positive agreement (children without a good visual acuity and a positive test in 7.6% and there was no agreement of the results in 11.0% (9 of the cases. CONCLUSION: The comparative analysis between the visual acuity test using the Snellen's E table and

  8. Baseline Predictors of Visual Acuity Outcome in Patients with Wet Age-Related Macular Degeneration

    Directory of Open Access Journals (Sweden)

    Xinyuan Zhang

    2018-01-01

    Full Text Available Age-related macular degeneration (AMD is one of the leading causes of severe vision loss in people over 60 years. Wet AMD (wAMD causes more severe visual acuity (VA loss compared with the dry form due to formation of choroidal neovascularization (CNV. Antivascular endothelial growth factor (anti-VEGF agents such as ranibizumab and aflibercept are now the standard of care treatment for wAMD. Unfortunately, up to a quarter of anti-VEGF-treated wAMD patients might not fully benefit from intravitreal injections and CNV activity may not respond to the treatment and these patients are called anti-VEGF nonresponders. This article aims to discuss the baseline factors associated with VA outcome such as age, initial VA, lesion types, disease duration, optical coherence tomography (OCT features, fundus autofluorescence findings, and the presence of particular genotype risk alleles in patients with wAMD. Recommendations are provided regarding when to consider discontinuation of therapy because of either success or futility. Understanding the predictive factors associated with VA outcome and treatment frequency response to anti-VEGF therapy may help retina specialists to manage patients’ expectations and guide treatment decisions from the beginning of treatment on the basis of “personalized medicine.”

  9. Species A rotavirus NSP3 acquires its translation inhibitory function prior to stable dimer formation.

    Directory of Open Access Journals (Sweden)

    Hugo I Contreras-Treviño

    Full Text Available Species A rotavirus non-structural protein 3 (NSP3 is a translational regulator that inhibits or, under some conditions, enhances host cell translation. NSP3 binds to the translation initiation factor eIF4G1 and evicts poly-(A binding protein (PABP from eIF4G1, thus inhibiting translation of polyadenylated mRNAs, presumably by disrupting the effect of PABP bound to their 3'-ends. NSP3 has a long coiled-coil region involved in dimerization that includes a chaperone Hsp90-binding domain (HS90BD. We aimed to study the role in NSP3 dimerization of a segment of the coiled-coil region adjoining the HS90BD. We used a vaccinia virus system to express NSP3 with point mutations in conserved amino acids in the coiled-coil region and determined the effects of these mutations on translation by metabolic labeling of proteins as well as on accumulation of stable NSP3 dimers by non-dissociating Western blot, a method that separates stable NSP3 dimers from the monomer/dimerization intermediate forms of the protein. Four of five mutations reduced the total yield of NSP3 and the formation of stable dimers (W170A, K171E, R173E and R187E:K191E, whereas one mutation had the opposite effects (Y192A. Treatment with the proteasome inhibitor MG132 revealed that stable NSP3 dimers and monomers/dimerization intermediates are susceptible to proteasome degradation. Surprisingly, mutants severely impaired in the formation of stable dimers were still able to inhibit host cell translation, suggesting that NSP3 dimerization intermediates are functional. Our results demonstrate that rotavirus NSP3 acquires its function prior to stable dimer formation and remain as a proteasome target throughout dimerization.

  10. Temperature and Humidity Control in Livestock Stables

    DEFF Research Database (Denmark)

    Hansen, Michael; Andersen, Palle; Nielsen, Kirsten M.

    2010-01-01

    The paper describes temperature and humidity control of a livestock stable. It is important to have a correct air flow pattern in the livestock stable in order to achieve proper temperature and humidity control as well as to avoid draught. In the investigated livestock stable the air flow...

  11. Microperimetry and optical coherent tomography in patients operated on y the conventional retinal detachment surgery

    International Nuclear Information System (INIS)

    Guerra Garcia, Roberto Alejandro; Rodriguez Rodriguez, Beatriz N; Eguia Martinez, Frank

    2008-01-01

    A descriptive study was made to determine the visual acuity, microperimetry and optical coherence tomography in patients operated on by the conventional rhegmatogenous retinal detachment at 'Ramon Pando Ferrer' Cuban Ophthalmologic Institute from October 2006 to March 2007. Twenty six patients, who had gone to the hospital with normal values in ophthalmoscopy and biomicroscopy and three-six months of disease development. Better corrected visual acuity, fixation, average sensitivity, morphology and macular thickness were obtained after surgery. Average visual acuity was 0,41 and fixation was stable in most of patients; average retinal sensitivity was 11 decibels. The most frequent finding was serum detachment. Average macular thickness was 246,3 micras. There was no statistical relation between preoperative time of disease development and the macular characteristics of detachment in these tests. (Author)

  12. Preparation of novel stable antibacterial nanoparticles using hydroxyethylcellulose and application in paper.

    Science.gov (United States)

    Wei, Dafu; Chen, Yan; Zhang, Youwei

    2016-01-20

    Taking advantage of the self-assembly between the components, novel stable antibacterial nanoparticles were efficiently fabricated via a facile one-step co-polymerization of acrylic acid (AA) and N,N'-methylenebisacrylamide (MBA) on a mixed aqueous solution of poly(hexamethylene guanidine hydrochloride) (PHMG) and hydroxyethylcellulose (HEC). The z-average hydrodynamic diameters of the nanoparticles ranged from 220 nm to 450 nm. The inner layer of the nanoparticles is composed of water-insoluble interpolymer complexes of PHMG and PAA networks, while the outer layer is composed of PHMG and HEC. The nanoparticles are stabilized by electrostatic interactions, hydrogen bonding interactions, and the chemical bonds. The nanoparticle solution remained stable in a wide pH range of 2.0-12.0 and at salt concentrations below 0.25 mol/L. The nanoparticles were incorporated into handsheets using a dipping treatment. The resulted handsheets exhibited excellent antimicrobial activities even after multiple water washing treatments. The nanoparticles are promising in fabricating paper, water-based coatings and textiles with permanent antibacterial activity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. The Myopic Stable Set for Social Environments

    NARCIS (Netherlands)

    Demuynck, Thomas; Herings, P. Jean-Jacques; Saulle, Riccardo; Seel, Christian

    2017-01-01

    We introduce a new solution concept for models of coalition formation, called the myopic stable set. The myopic stable set is defined for a very general class of social environments and allows for an infinite state space. We show that the myopic stable set exists and is non-empty. Under minor

  14. Stable isotope analysis in primatology: a critical review.

    Science.gov (United States)

    Sandberg, Paul A; Loudon, James E; Sponheimer, Matt

    2012-11-01

    Stable isotope analysis has become an important tool in ecology over the last 25 years. A wealth of ecological information is stored in animal tissues in the relative abundances of the stable isotopes of several elements, particularly carbon and nitrogen, because these isotopes navigate through ecological processes in predictable ways. Stable carbon and nitrogen isotopes have been measured in most primate taxonomic groups and have yielded information about dietary content, dietary variability, and habitat use. Stable isotopes have recently proven useful for addressing more fine-grained questions about niche dynamics and anthropogenic effects on feeding ecology. Here, we discuss stable carbon and nitrogen isotope systematics and critically review the published stable carbon and nitrogen isotope data for modern primates with a focus on the problems and prospects for future stable isotope applications in primatology. © 2012 Wiley Periodicals, Inc.

  15. Stable cycling in discrete-time genetic models.

    OpenAIRE

    Hastings, A

    1981-01-01

    Examples of stable cycling are discussed for two-locus, two-allele, deterministic, discrete-time models with constant fitnesses. The cases that cycle were found by using numerical techniques to search for stable Hopf bifurcations. One consequence of the results is that apparent cases of directional selection may be due to stable cycling.

  16. Stable cycling in discrete-time genetic models.

    Science.gov (United States)

    Hastings, A

    1981-11-01

    Examples of stable cycling are discussed for two-locus, two-allele, deterministic, discrete-time models with constant fitnesses. The cases that cycle were found by using numerical techniques to search for stable Hopf bifurcations. One consequence of the results is that apparent cases of directional selection may be due to stable cycling.

  17. Local Search Approaches in Stable Matching Problems

    Directory of Open Access Journals (Sweden)

    Toby Walsh

    2013-10-01

    Full Text Available The stable marriage (SM problem has a wide variety of practical applications, ranging from matching resident doctors to hospitals, to matching students to schools or, more generally, to any two-sided market. In the classical formulation, n men and n women express their preferences (via a strict total order over the members of the other sex. Solving an SM problem means finding a stable marriage where stability is an envy-free notion: no man and woman who are not married to each other would both prefer each other to their partners or to being single. We consider both the classical stable marriage problem and one of its useful variations (denoted SMTI (Stable Marriage with Ties and Incomplete lists where the men and women express their preferences in the form of an incomplete preference list with ties over a subset of the members of the other sex. Matchings are permitted only with people who appear in these preference lists, and we try to find a stable matching that marries as many people as possible. Whilst the SM problem is polynomial to solve, the SMTI problem is NP-hard. We propose to tackle both problems via a local search approach, which exploits properties of the problems to reduce the size of the neighborhood and to make local moves efficiently. We empirically evaluate our algorithm for SM problems by measuring its runtime behavior and its ability to sample the lattice of all possible stable marriages. We evaluate our algorithm for SMTI problems in terms of both its runtime behavior and its ability to find a maximum cardinality stable marriage. Experimental results suggest that for SM problems, the number of steps of our algorithm grows only as O(n log(n, and that it samples very well the set of all stable marriages. It is thus a fair and efficient approach to generate stable marriages. Furthermore, our approach for SMTI problems is able to solve large problems, quickly returning stable matchings of large and often optimal size, despite the

  18. Stable beams

    CERN Multimedia

    2015-01-01

    Stable beams: two simple words that carry so much meaning at CERN. When LHC page one switched from "squeeze" to "stable beams" at 10.40 a.m. on Wednesday, 3 June, it triggered scenes of jubilation in control rooms around the CERN sites, as the LHC experiments started to record physics data for the first time in 27 months. This is what CERN is here for, and it’s great to be back in business after such a long period of preparation for the next stage in the LHC adventure.   I’ve said it before, but I’ll say it again. This was a great achievement, and testimony to the hard and dedicated work of so many people in the global CERN community. I could start to list the teams that have contributed, but that would be a mistake. Instead, I’d simply like to say that an achievement as impressive as running the LHC – a machine of superlatives in every respect – takes the combined effort and enthusiasm of everyone ...

  19. Stable isotope research pool inventory

    International Nuclear Information System (INIS)

    1980-12-01

    This report contains a listing of electromagnetically separated stable isotopes which are available for distribution within the United States for non-destructive research use from the Oak Ridge National Laboratory on a loan basis. This inventory includes all samples of stable isotopes in the Materials Research Collection and does not designate whether a sample is out on loan or in reprocessing

  20. Effectiveness and risks of stable iodine prophylaxis

    International Nuclear Information System (INIS)

    Waight, P.J.

    1995-01-01

    The factors upon which the efficacy of stable iodine prophylaxis depends are reviewed, with particular reference to the dose of stable iodine, the timing of the dose, the influence of dietary iodine and the impact of the other prospective actions. The risks of stable iodine ingestion are estimated, and their application to the principle of Justification in outlined. (Author)

  1. Uncorrected and Corrected Distance Visual Acuity, Predictability, Efficacy, and Safety after Femtosecond Laser in Situ Keratomileusis (FS-LASIK) and Refractive Lenticule extraction (ReLEx) for Moderate and High Myopia

    DEFF Research Database (Denmark)

    Vestergaard, Anders; Justesen, Birgitte Larsen; Melsen, Charlotte

    Title: Uncorrected and Corrected Distance Visual Acuity, Predictability, Efficacy, and Safety after Femtosecond Laser in Situ Keratomileusis (FS-LASIK) and Refractive Lenticule extraction (ReLEx) for Moderate and High Myopia. Vestergaard A., Justesen B., Melsen C., Lyhne N., Department of Ophthal......Title: Uncorrected and Corrected Distance Visual Acuity, Predictability, Efficacy, and Safety after Femtosecond Laser in Situ Keratomileusis (FS-LASIK) and Refractive Lenticule extraction (ReLEx) for Moderate and High Myopia. Vestergaard A., Justesen B., Melsen C., Lyhne N., Department...... predictability, efficacy and safety after femtosecond LASIK (FS-LASIK) with ReLEx. Setting: Department of Ophthalmology, Odense University Hospital, Denmark. Methods: Retrospective study of results after FS-LASIK and ReLEx (including ReLEx flex, ReLEx pseudo-smile, and ReLEx smile). In total, 228 eyes were...... treated with FS-LASIK and 83 eyes with ReLEx, at the Department of Ophthalmology, Odense University Hospital in the period of April to November 2011. Only otherwise healthy myopic eyes with up to 3.00 D of astigmatism and with CDVA ≤ 0.30 (logMAR) before surgery were included in this study. FS-LASIK flaps...

  2. Forensic Stable Isotope Biogeochemistry

    Science.gov (United States)

    Cerling, Thure E.; Barnette, Janet E.; Bowen, Gabriel J.; Chesson, Lesley A.; Ehleringer, James R.; Remien, Christopher H.; Shea, Patrick; Tipple, Brett J.; West, Jason B.

    2016-06-01

    Stable isotopes are being used for forensic science studies, with applications to both natural and manufactured products. In this review we discuss how scientific evidence can be used in the legal context and where the scientific progress of hypothesis revisions can be in tension with the legal expectations of widely used methods for measurements. Although this review is written in the context of US law, many of the considerations of scientific reproducibility and acceptance of relevant scientific data span other legal systems that might apply different legal principles and therefore reach different conclusions. Stable isotopes are used in legal situations for comparing samples for authenticity or evidentiary considerations, in understanding trade patterns of illegal materials, and in understanding the origins of unknown decedents. Isotope evidence is particularly useful when considered in the broad framework of physiochemical processes and in recognizing regional to global patterns found in many materials, including foods and food products, drugs, and humans. Stable isotopes considered in the larger spatial context add an important dimension to forensic science.

  3. Ballooning stable high beta tokamak equilibria

    International Nuclear Information System (INIS)

    Tuda, Takashi; Azumi, Masafumi; Kurita, Gen-ichi; Takizuka, Tomonori; Takeda, Tatsuoki

    1981-04-01

    The second stable regime of ballooning modes is numerically studied by using the two-dimensional tokamak transport code with the ballooning stability code. Using the simple FCT heating scheme, we find that the plasma can locally enter this second stable regime. And we obtained equilibria with fairly high beta (β -- 23%) stable against ballooning modes in a whole plasma region, by taking into account of finite thermal diffusion due to unstable ballooning modes. These results show that a tokamak fusion reactor can operate in a high beta state, which is economically favourable. (author)

  4. Severe Vaso-occlusive Retinopathy as the Primary Manifestation in a Patient with Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Tsung-Yu Ho

    2008-07-01

    Full Text Available Severe vaso-occlusive retinopathy as the initial manifestation of systemic lupus erythematosus (SLE is rare. We report a 16-year-old female who developed bilateral visual impairment. Fundus examinations showed bilateral “cherry-red spot” appearance, multiple confluent cotton wool spots, and widespread arterial occlusion. Laboratory studies showed leukopenia, antinuclear antibody (+, and anti-double-stranded DNA antibody (+. Malar rashes, oral ulcers, and bilateral knee joint tenderness were noted during physical examination. SLE was diagnosed and pulse therapy started immediately. Best corrected visual acuity of the left eye improved to 6/10 after treatment. However, there was no visual improvement in the right eye. Four months later, bilateral panretinal laser photocoagulation was performed due to retinal neovascularization. However, tractional retinal detachment of the right eye and vitreous hemorrhage of the left eye still occurred. After undergoing cryoretinopexy of the right eye and intravitreous tissue plasminogen activator injection of the left eye, the visual acuity of the patient's right eye remained hand movement only at 10 cm, but that of the left eye returned to 6/10. The ocular and systemic conditions were stable in the follow-up period of more than 2 years. This case demonstrates that in patients with severe vaso-occlusive retinopathy, a generalized immunological disorder, like SLE, should be suspected.

  5. Briquettes of plant remains from the greenhouses of Almeria (Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Callejon-Ferre, A. J.; Lopez-Martinez, J. A.

    2009-07-01

    Since ancient times, plant biomass has been used as a primary fuel, and today, with the impending depletion of fossil fuels, these vegetal sources constitute a cleaner alternative and furthermore have a multitude of uses. The aim of the present study is to design a method of recycling and reuse of plant wastes from intensive agriculture under plastic, by manufacturing briquettes in an environmentally friendly manner. In Almeria (SE Spain), agriculture generates 769,500 t year{sup -}1 of plant remains from greenhouse-grown horticultural crops, a resource currently used for composting and for producing electricity.With the machinery and procedures of the present study, another potential use has been developed by detoxifying and eliminating the plastic wastes of the original biomass for the fabrication of briquettes for fireplaces. The results were slightly inferior to the commercial briquette from other non-horticultural plant materials (no forestry material), specifically 2512 kJ kg{sup -}1, in the least favourable case. On the contrary, the heating value with respect to the two charcoals was significantly lower, with a difference of 12,142 kJ kg{sup -}1. In conclusion; a procedure, applicable in ecological cultivation without agrochemicals or plastic cords, has been developed and tested to reuse and transform plant materials from intensive cultivation into a stable non-toxic product similar to composite logs, applicable in commercial settings or in residential fireplaces. (Author) 48 refs.

  6. Photorefractive keratectomy with corneal collagen cross-linking 1 year after intrastromal corneal ring segment implantation for the treatment of keratoconus

    Directory of Open Access Journals (Sweden)

    Maha Elfayoumi

    2016-01-01

    Conclusion PRK with CXL can be used to enhance aided and unaided visual acuity after treatment of keratoconus with Intacs implants, with a stable refractive outcome, and could postpone penetrating or lamellar keratoplasty in patients with the visually disabling disease of moderate keratoconus.

  7. Tukey max-stable processes for spatial extremes

    KAUST Repository

    Xu, Ganggang

    2016-09-21

    We propose a new type of max-stable process that we call the Tukey max-stable process for spatial extremes. It brings additional flexibility to modeling dependence structures among spatial extremes. The statistical properties of the Tukey max-stable process are demonstrated theoretically and numerically. Simulation studies and an application to Swiss rainfall data indicate the effectiveness of the proposed process. © 2016 Elsevier B.V.

  8. Recapitulation of physiological spatiotemporal signals promotes in vitro formation of phenotypically stable human articular cartilage

    Science.gov (United States)

    Wei, Yiyong; Zhou, Bin; Bernhard, Jonathan; Robinson, Samuel; Burapachaisri, Aonnicha; Guo, X. Edward

    2017-01-01

    Standard isotropic culture fails to recapitulate the spatiotemporal gradients present during native development. Cartilage grown from human mesenchymal stem cells (hMSCs) is poorly organized and unstable in vivo. We report that human cartilage with physiologic organization and in vivo stability can be grown in vitro from self-assembling hMSCs by implementing spatiotemporal regulation during induction. Self-assembling hMSCs formed cartilage discs in Transwell inserts following isotropic chondrogenic induction with transforming growth factor β to set up a dual-compartment culture. Following a switch in the basal compartment to a hypertrophic regimen with thyroxine, the cartilage discs underwent progressive deep-zone hypertrophy and mineralization. Concurrent chondrogenic induction in the apical compartment enabled the maintenance of functional and hyaline cartilage. Cartilage homeostasis, chondrocyte maturation, and terminal differentiation markers were all up-regulated versus isotropic control groups. We assessed the in vivo stability of the cartilage formed under different induction regimens. Cartilage formed under spatiotemporal regulation in vitro resisted endochondral ossification, retained the expression of cartilage markers, and remained organized following s.c. implantation in immunocompromised mice. In contrast, the isotropic control groups underwent endochondral ossification. Cartilage formed from hMSCs remained stable and organized in vivo. Spatiotemporal regulation during induction in vitro recapitulated some aspects of native cartilage development, and potentiated the maturation of self-assembling hMSCs into stable and organized cartilage resembling the native articular cartilage. PMID:28228529

  9. Variação da acuidade visual em pacientes jovens com ectopia lentis submetidos à cirurgia Variation of visual acuity in young patients with ectopia lentis submitted to surgery

    Directory of Open Access Journals (Sweden)

    Mauro Waiswol

    2005-08-01

    Full Text Available OBJETIVOS:Avaliar os resultados quanto à acuidade visual, de dois procedimentos cirúrgicos para a ectopia lentis. MÉTODOS: Foram operados 51 olhos de 28 pacientes (16 do sexo masculino e 12 do feminino, com média de idade de 16,00±8,5 anos com ectopia lentis simples (19 casos, ou associada à síndrome de Marfan (nove casos, com diferentes graus de subluxação cristaliniana. Em 21 casos a técnica empregada foi a facectomia com implante de lente intra-ocular (LIO por fixação escleral e em 30 casos foi utilizada a facectomia com implante da lente intra-ocular no saco capsular, previamente expandido por anel endocapsular (ANEL. Os resultados enfatizaram a acuidade visual pré e pós-operatória em seguimento de seis meses. RESULTADOS:Em ambas as técnicas, a acuidade visual pós-operatória sem e com correção teve aumento significante, que foi maior nos casos operados com fixação escleral da lente intra-ocular. Mais do que a técnica empregada, os graus de subluxação pré-operatórios foram determinantes para os resultados. CONCLUSÕES: Mediante as técnicas operatórias apresentadas, a correção cirúrgica da ectopia lentis simples ou associada à síndrome de Marfan é segura e eficaz, com recuperação significante da acuidade visual, embora os resultados operatórios dependam, intrinsecamente, dos graus pré-operatórios de subluxação do cristalino.PURPOSE: To assess the results as to visual acuity of two different surgical procedures for ectopia lentis. METHODS: Fifty-one eyes of 28 patients (16 males and 12 females, mean age 16.00± 8.5 with simple (19 cases or Marfan syndrome-associated (9 cases ectopia lentis with different levels of subluxation underwent lens extraction with implantation of intraocular lenses (IOL with scleral fixation (21 cases or by lens extraction with implantation of the intraocular lenses in the capsular bag expanded by endocapsular ring (RING (30 cases. Result analysis emphasized pre- and

  10. Long-term results of radiotherapy for subfoveal choroidal neovascularization (CNV) in age-related macular degeneration (ARMD)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Kyong; Kim, Il Han [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2007-06-15

    We performed this prospective randomized study to evaluate the efficacy and the complications of radiotherapy for Subfoveal CNV in ARMD and to compare the treatment results at two dosages (14.4 Gy and 19.8 Gy). 60 eyes of 55 patients were enrolled, and randomized into 14.4 Gy (31 eyes) or 19.8 Gy (29 eyes) groups. CT was used to plan the radiotherapy. All patients received radiotherapy with a 1.8 Gy daily dose using 4 MV photon. We categorized treatment results as improved, stable, or deteriorated based on visual acuity changes of more than 2 lines on the ETDRS chart. Median follow-up period was 33.5 months. At 12 months, visual acuity improved in 9 (16.7%), stable in 41 (75.9%), and aggravated in 4 (7.4%) of 54 evaluated eyes. At 24 months, 49 eyes (81.7%) were evaluated. Visual acuity improved in 6 (12.2%), was stable in 33 (67.4%), and deteriorated in 10 (20.4%). At 36 months, 37 eyes were evaluated. Six (16.2%) eyes were improved, 21 (56.8%) stable, and 10 (27.0%) deteriorated. No significant difference in response was observed between the 14.4 Gy and 19.8 Gy groups (Mantel-Haenszel {chi} {sup 2} = 0.4756). The proportion of eyes with a vision of 20/100 {<=} increased from 28.3% initially to 32.7% after 24 months of radiotherapy. There were no severe acute or chronic complications. External beam radiotherapy with doses of 14.4 or 19.8 Gy may be an effective treatment for subfoveal CNV in ARMD. No dose-response relationships with respect to treatment response or toxicity were observed between the 14.4 Gy and 19.8 Gy groups.

  11. Chance and stability stable distributions and their applications

    CERN Document Server

    Uchaikin, Vladimir V

    1999-01-01

    An introduction to the theory of stable distributions and their applications. It contains a modern outlook on the mathematical aspects of the theory. The authors explain numerous peculiarities of stable distributions and describe the principle concept of probability theory and function analysis. A significant part of the book is devoted to applications of stable distributions. Another notable feature is the material on the interconnection of stable laws with fractals, chaos and anomalous transport processes.

  12. Highly polarized light from stable ordered magnetic fields in GRB 120308A.

    Science.gov (United States)

    Mundell, C G; Kopač, D; Arnold, D M; Steele, I A; Gomboc, A; Kobayashi, S; Harrison, R M; Smith, R J; Guidorzi, C; Virgili, F J; Melandri, A; Japelj, J

    2013-12-05

    After the initial burst of γ-rays that defines a γ-ray burst (GRB), expanding ejecta collide with the circumburst medium and begin to decelerate at the onset of the afterglow, during which a forward shock travels outwards and a reverse shock propagates backwards into the oncoming collimated flow, or 'jet'. Light from the reverse shock should be highly polarized if the jet's magnetic field is globally ordered and advected from the central engine, with a position angle that is predicted to remain stable in magnetized baryonic jet models or vary randomly with time if the field is produced locally by plasma or magnetohydrodynamic instabilities. Degrees of linear polarization of P ≈ 10 per cent in the optical band have previously been detected in the early afterglow, but the lack of temporal measurements prevented definitive tests of competing jet models. Hours to days after the γ-ray burst, polarization levels are low (P < 4 per cent), when emission from the shocked ambient medium dominates. Here we report the detection of P =28(+4)(-4) per cent in the immediate afterglow of Swift γ-ray burst GRB 120308A, four minutes after its discovery in the γ-ray band, decreasing to P = 16(+5)(-4) per cent over the subsequent ten minutes. The polarization position angle remains stable, changing by no more than 15 degrees over this time, with a possible trend suggesting gradual rotation and ruling out plasma or magnetohydrodynamic instabilities. Instead, the polarization properties show that GRBs contain magnetized baryonic jets with large-scale uniform fields that can survive long after the initial explosion.

  13. Climate, Environment and Early Human Innovation: Stable Isotope and Faunal Proxy Evidence from Archaeological Sites (98-59ka in the Southern Cape, South Africa.

    Directory of Open Access Journals (Sweden)

    Patrick Roberts

    Full Text Available The Middle Stone Age (MSA of southern Africa, and in particular its Still Bay and Howiesons Poort lithic traditions, represents a period of dramatic subsistence, cultural, and technological innovation by our species, Homo sapiens. Climate change has frequently been postulated as a primary driver of the appearance of these innovative behaviours, with researchers invoking either climate instability as a reason for the development of buffering mechanisms, or environmentally stable refugia as providing a stable setting for experimentation. Testing these alternative models has proved intractable, however, as existing regional palaeoclimatic and palaeoenvironmental records remain spatially, stratigraphically, and chronologically disconnected from the archaeological record. Here we report high-resolution records of environmental shifts based on stable carbon and oxygen isotopes in ostrich eggshell (OES fragments, faunal remains, and shellfish assemblages excavated from two key MSA archaeological sequences, Blombos Cave and Klipdrift Shelter. We compare these records with archaeological material remains in the same strata. The results from both sites, spanning the periods 98-73 ka and 72-59 ka, respectively, show significant changes in vegetation, aridity, rainfall seasonality, and sea temperature in the vicinity of the sites during periods of human occupation. While these changes clearly influenced human subsistence strategies, we find that the remarkable cultural and technological innovations seen in the sites cannot be linked directly to climate shifts. Our results demonstrate the need for scale-appropriate, on-site testing of behavioural-environmental links, rather than broader, regional comparisons.

  14. Climate, Environment and Early Human Innovation: Stable Isotope and Faunal Proxy Evidence from Archaeological Sites (98-59ka) in the Southern Cape, South Africa.

    Science.gov (United States)

    Roberts, Patrick; Henshilwood, Christopher S; van Niekerk, Karen L; Keene, Petro; Gledhill, Andrew; Reynard, Jerome; Badenhorst, Shaw; Lee-Thorp, Julia

    2016-01-01

    The Middle Stone Age (MSA) of southern Africa, and in particular its Still Bay and Howiesons Poort lithic traditions, represents a period of dramatic subsistence, cultural, and technological innovation by our species, Homo sapiens. Climate change has frequently been postulated as a primary driver of the appearance of these innovative behaviours, with researchers invoking either climate instability as a reason for the development of buffering mechanisms, or environmentally stable refugia as providing a stable setting for experimentation. Testing these alternative models has proved intractable, however, as existing regional palaeoclimatic and palaeoenvironmental records remain spatially, stratigraphically, and chronologically disconnected from the archaeological record. Here we report high-resolution records of environmental shifts based on stable carbon and oxygen isotopes in ostrich eggshell (OES) fragments, faunal remains, and shellfish assemblages excavated from two key MSA archaeological sequences, Blombos Cave and Klipdrift Shelter. We compare these records with archaeological material remains in the same strata. The results from both sites, spanning the periods 98-73 ka and 72-59 ka, respectively, show significant changes in vegetation, aridity, rainfall seasonality, and sea temperature in the vicinity of the sites during periods of human occupation. While these changes clearly influenced human subsistence strategies, we find that the remarkable cultural and technological innovations seen in the sites cannot be linked directly to climate shifts. Our results demonstrate the need for scale-appropriate, on-site testing of behavioural-environmental links, rather than broader, regional comparisons.

  15. French days on stable isotopes

    International Nuclear Information System (INIS)

    2000-01-01

    These first French days on stable isotopes took place in parallel with the 1. French days of environmental chemistry. Both conferences had common plenary sessions. The conference covers all aspects of the use of stable isotopes in the following domains: medicine, biology, environment, tracer techniques, agronomy, food industry, geology, petroleum geochemistry, cosmo-geochemistry, archaeology, bio-geochemistry, hydrology, climatology, nuclear and particle physics, astrophysics, isotope separations etc.. Abstracts available on CD-Rom only. (J.S.)

  16. Pharmaceuticals labelled with stable isotopes

    International Nuclear Information System (INIS)

    Krumbiegel, P.

    1986-11-01

    The relatively new field of pharmaceuticals labelled with stable isotopes is reviewed. Scientific, juridical, and ethical questions are discussed concerning the application of these pharmaceuticals in human medicine. 13 C, 15 N, and 2 H are the stable isotopes mainly utilized in metabolic function tests. Methodical contributions are given to the application of 2 H, 13 C, and 15 N pharmaceuticals showing new aspects and different states of development in the field under discussion. (author)

  17. Development of a Safety Management Web Tool for Horse Stables.

    Science.gov (United States)

    Leppälä, Jarkko; Kolstrup, Christina Lunner; Pinzke, Stefan; Rautiainen, Risto; Saastamoinen, Markku; Särkijärvi, Susanna

    2015-11-12

    Managing a horse stable involves risks, which can have serious consequences for the stable, employees, clients, visitors and horses. Existing industrial or farm production risk management tools are not directly applicable to horse stables and they need to be adapted for use by managers of different types of stables. As a part of the InnoEquine project, an innovative web tool, InnoHorse, was developed to support horse stable managers in business, safety, pasture and manure management. A literature review, empirical horse stable case studies, expert panel workshops and stakeholder interviews were carried out to support the design. The InnoHorse web tool includes a safety section containing a horse stable safety map, stable safety checklists, and examples of good practices in stable safety, horse handling and rescue planning. This new horse stable safety management tool can also help in organizing work processes in horse stables in general.

  18. Fish remains and humankind: part two

    Directory of Open Access Journals (Sweden)

    Andrew K G Jones

    1998-07-01

    Full Text Available The significance of aquatic resources to past human groups is not adequately reflected in the published literature - a deficiency which is gradually being acknowledged by the archaeological community world-wide. The publication of the following three papers goes some way to redress this problem. Originally presented at an International Council of Archaeozoology (ICAZ Fish Remains Working Group meeting in York, U.K. in 1987, these papers offer clear evidence of the range of interest in ancient fish remains across the world. Further papers from the York meeting were published in Internet Archaeology 3 in 1997.

  19. Feasibility Study on the Use of the Seeding Growth Technique in Producing a Highly Stable Gold Nanoparticle Colloidal System

    Directory of Open Access Journals (Sweden)

    Kim Han Tan

    2015-01-01

    Full Text Available Stable colloidal gold nanoparticles (Au NPs are synthesized successfully using a seeding growth technique. The size of the nanoparticles is determined using transmission electron microscopy (TEM, and it is observed that the size of the nanoparticles ranges from 7 to 30 nm. The TEM images and optical absorption spectra of the Au NPs reveal that the suspension is well dispersed and consistent with the particle size. The feasibility of the seeding growth technique is investigated using Turbiscan Classic MA 2000 screening stability tester. Based on the peak thickness kinetics and mean value kinetics, the backscattered light profiles indicate that the suspension is highly stable without particle sedimentation as well as negligible agglomeration. In addition, the Au NPs are proven to remain stable over a period of 2 months. Particle sedimentation eventually occurs due to the weight of nanoparticles. It is concluded that the seeding growth technique is feasible in synthesizing stable Au NPs. Controlling the stability, size and shape of Au NPs are technologically important because of the strong correlation between these parameters and the optical, electrical, and catalytic properties of the nanoparticles.

  20. Stable xenon CT measurement of cerebral blood flow in cardiac transplantation candidates: Correlation with cognitive function

    International Nuclear Information System (INIS)

    Bello, J.A.; Fink, M.E.; Hilal, S.K.; Rose, E.A.; Reemtsma, K.

    1987-01-01

    Thirteen consecutive unselected patients with NYHA class 4 cardiac failure referred for cardiac transplantation underwent neurologic examination and cerebral blood flow measurement (rCBF) using the stable xenon enhanced CT method on a GE9800 system. Eleven men and two women were studied (mean age = 43.8 +- 6.1). On neurological examination, six of the patients demonstrated normal mental function; the remaining seven patients demonstrated memory, language, or learning impairment. There was no difference in mean cardiac output between the groups (4.9 L/min +- 1.68 vs. 4.2L/min +- 1.57). rCBF was significantly reduced in the impaired group. Cognitive impairment in patients with cardiac failure can be correlated with cerebral ischemia. Stable xenon CT measurement of rCBF in transplant candidates may help identify patients requiring more rapid transplantation to prevent permanent cerebral injury

  1. Highly stable noble-metal nanoparticles in tetraalkylphosphonium ionic liquids for in situ catalysis.

    Science.gov (United States)

    Banerjee, Abhinandan; Theron, Robin; Scott, Robert W J

    2012-01-09

    Gold and palladium nanoparticles were prepared by lithium borohydride reduction of the metal salt precursors in tetraalkylphosphonium halide ionic liquids in the absence of any organic solvents or external nanoparticle stabilizers. These colloidal suspensions remained stable and showed no nanoparticle agglomeration over many months. A combination of electrostatic interactions between the coordinatively unsaturated metal nanoparticle surface and the ionic-liquid anions, bolstered by steric protection offered by the bulky alkylated phosphonium cations, is likely to be the reason behind such stabilization. The halide anion strongly absorbs to the nanoparticle surface, leading to exceptional nanoparticle stability in halide ionic liquids; other tetraalkylphosphonium ionic liquids with non-coordinating anions, such as tosylate and hexafluorophosphate, show considerably lower affinities towards the stabilization of nanoparticles. Palladium nanoparticles stabilized in the tetraalkylphosphonium halide ionic liquid were stable, efficient, and recyclable catalysts for a variety of hydrogenation reactions at ambient pressures with sustained activity. Aerial oxidation of the metal nanoparticles occurred over time and was readily reversed by re-reduction of oxidized metal salts. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Tempered stable distributions stochastic models for multiscale processes

    CERN Document Server

    Grabchak, Michael

    2015-01-01

    This brief is concerned with tempered stable distributions and their associated Levy processes. It is a good text for researchers interested in learning about tempered stable distributions.  A tempered stable distribution is one which takes a stable distribution and modifies its tails to make them lighter. The motivation for this class comes from the fact that infinite variance stable distributions appear to provide a good fit to data in a variety of situations, but the extremely heavy tails of these models are not realistic for most real world applications. The idea of using distributions that modify the tails of stable models to make them lighter seems to have originated in the influential paper of Mantegna and Stanley (1994). Since then, these distributions have been extended and generalized in a variety of ways. They have been applied to a wide variety of areas including mathematical finance, biostatistics,computer science, and physics.

  3. Hydrothermally stable molecular separation membranes from organically linked silica

    Energy Technology Data Exchange (ETDEWEB)

    Castricum, H.L.; Sah, A; Blank, D.H.A.; Ten Elshof, J.E. [Inorganic Materials Science, MESA Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede (Netherlands); Kreiter, R.; Vente, J.F. [ECN Energy Efficiency in the Industry, Petten (Netherlands)

    2008-06-15

    A highly hydrothermally stable microporous network material has been developed that can be applied in energy-efficient molecular sieving. The material was synthesized by employing organically bridged monomers in acid-catalysed sol-gel hydrolysis and condensation, and is composed of covalently bonded organic and inorganic moieties. Due to its hybrid nature, it withstands higher temperatures than organic polymers and exhibits high solvolytical and acid stability. A thin film membrane that was prepared with the hybrid material was found to be stable in the dehydration of n-butanol at 150C for almost two years. This membrane is the first that combines a high resistance against water at elevated temperatures with a high separation factor and permeance. It therefore has high potential for energy-efficient molecular separation under industrial conditions, including the dehydration of organic solvents. The organically bridged monomers induce increased toughness in the thin film layer. This suppresses hydrolysis of Si-O-Si network bonds and results in a high resistance towards stress-induced cracking. The large non-hydrolysable units thus remain well incorporated in the surrounding matrix such that the material combines high (pore) structural and mechanical stability. The sol mean particle size was found to be a viable parameter to tune the thickness of the membrane layer and thus optimize the separation performance. We anticipate that other hybrid organosilicas can be made in a similar fashion, to yield a whole new class of materials with superior molecular sieving properties and high hydrothermal stability.

  4. Stable Chimeras and Independently Synchronizable Clusters

    Science.gov (United States)

    Cho, Young Sul; Nishikawa, Takashi; Motter, Adilson E.

    2017-08-01

    Cluster synchronization is a phenomenon in which a network self-organizes into a pattern of synchronized sets. It has been shown that diverse patterns of stable cluster synchronization can be captured by symmetries of the network. Here, we establish a theoretical basis to divide an arbitrary pattern of symmetry clusters into independently synchronizable cluster sets, in which the synchronization stability of the individual clusters in each set is decoupled from that in all the other sets. Using this framework, we suggest a new approach to find permanently stable chimera states by capturing two or more symmetry clusters—at least one stable and one unstable—that compose the entire fully symmetric network.

  5. Stable isotopes in Lithuanian bioarcheological material

    Science.gov (United States)

    Skipityte, Raminta; Jankauskas, Rimantas; Remeikis, Vidmantas

    2015-04-01

    Investigation of bioarcheological material of ancient human populations allows us to understand the subsistence behavior associated with various adaptations to the environment. Feeding habits are essential to the survival and growth of ancient populations. Stable isotope analysis is accepted tool in paleodiet (Schutkowski et al, 1999) and paleoenvironmental (Zernitskaya et al, 2014) studies. However, stable isotopes can be useful not only in investigating human feeding habits but also in describing social and cultural structure of the past populations (Le Huray and Schutkowski, 2005). Only few stable isotope investigations have been performed before in Lithuanian region suggesting a quite uniform diet between males and females and protein intake from freshwater fish and animal protein. Previously, stable isotope analysis has only been used to study a Stone Age population however, more recently studies have been conducted on Iron Age and Late medieval samples (Jacobs et al, 2009). Anyway, there was a need for more precise examination. Stable isotope analysis were performed on human bone collagen and apatite samples in this study. Data represented various ages (from 5-7th cent. to 18th cent.). Stable carbon and nitrogen isotope analysis on medieval populations indicated that individuals in studied sites in Lithuania were almost exclusively consuming C3 plants, C3 fed terrestrial animals, and some freshwater resources. Current investigation demonstrated social differences between elites and country people and is promising in paleodietary and daily life reconstruction. Acknowledgement I thank prof. dr. G. Grupe, Director of the Anthropological and Palaeoanatomical State Collection in Munich for providing the opportunity to work in her laboratory. The part of this work was funded by DAAD. Antanaitis-Jacobs, Indre, et al. "Diet in early Lithuanian prehistory and the new stable isotope evidence." Archaeologia Baltica 12 (2009): 12-30. Le Huray, Jonathan D., and Holger

  6. Stable isotope research pool inventory

    International Nuclear Information System (INIS)

    1984-03-01

    This report contains a listing of electromagnetically separated stable isotopes which are available at the Oak Ridge National Laboratory for distribution for nondestructive research use on a loan basis. This inventory includes all samples of stable isotopes in the Research Materials Collection and does not designate whether a sample is out on loan or is in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56

  7. Origins of superior dynamic visual acuity in baseball players: superior eye movements or superior image processing.

    Directory of Open Access Journals (Sweden)

    Yusuke Uchida

    Full Text Available Dynamic visual acuity (DVA is defined as the ability to discriminate the fine parts of a moving object. DVA is generally better in athletes than in non-athletes, and the better DVA of athletes has been attributed to a better ability to track moving objects. In the present study, we hypothesized that the better DVA of athletes is partly derived from better perception of moving images on the retina through some kind of perceptual learning. To test this hypothesis, we quantitatively measured DVA in baseball players and non-athletes using moving Landolt rings in two conditions. In the first experiment, the participants were allowed to move their eyes (free-eye-movement conditions, whereas in the second they were required to fixate on a fixation target (fixation conditions. The athletes displayed significantly better DVA than the non-athletes in the free-eye-movement conditions. However, there was no significant difference between the groups in the fixation conditions. These results suggest that the better DVA of athletes is primarily due to an improved ability to track moving targets with their eyes, rather than to improved perception of moving images on the retina.

  8. Origins of superior dynamic visual acuity in baseball players: superior eye movements or superior image processing.

    Science.gov (United States)

    Uchida, Yusuke; Kudoh, Daisuke; Murakami, Akira; Honda, Masaaki; Kitazawa, Shigeru

    2012-01-01

    Dynamic visual acuity (DVA) is defined as the ability to discriminate the fine parts of a moving object. DVA is generally better in athletes than in non-athletes, and the better DVA of athletes has been attributed to a better ability to track moving objects. In the present study, we hypothesized that the better DVA of athletes is partly derived from better perception of moving images on the retina through some kind of perceptual learning. To test this hypothesis, we quantitatively measured DVA in baseball players and non-athletes using moving Landolt rings in two conditions. In the first experiment, the participants were allowed to move their eyes (free-eye-movement conditions), whereas in the second they were required to fixate on a fixation target (fixation conditions). The athletes displayed significantly better DVA than the non-athletes in the free-eye-movement conditions. However, there was no significant difference between the groups in the fixation conditions. These results suggest that the better DVA of athletes is primarily due to an improved ability to track moving targets with their eyes, rather than to improved perception of moving images on the retina.

  9. Investigating the Relationship between Stable Personality Characteristics and Automatic Imitation.

    Science.gov (United States)

    Butler, Emily E; Ward, Robert; Ramsey, Richard

    2015-01-01

    Automatic imitation is a cornerstone of nonverbal communication that fosters rapport between interaction partners. Recent research has suggested that stable dimensions of personality are antecedents to automatic imitation, but the empirical evidence linking imitation with personality traits is restricted to a few studies with modest sample sizes. Additionally, atypical imitation has been documented in autism spectrum disorders and schizophrenia, but the mechanisms underpinning these behavioural profiles remain unclear. Using a larger sample than prior studies (N=243), the current study tested whether performance on a computer-based automatic imitation task could be predicted by personality traits associated with social behaviour (extraversion and agreeableness) and with disorders of social cognition (autistic-like and schizotypal traits). Further personality traits (narcissism and empathy) were assessed in a subsample of participants (N=57). Multiple regression analyses showed that personality measures did not predict automatic imitation. In addition, using a similar analytical approach to prior studies, no differences in imitation performance emerged when only the highest and lowest 20 participants on each trait variable were compared. These data weaken support for the view that stable personality traits are antecedents to automatic imitation and that neural mechanisms thought to support automatic imitation, such as the mirror neuron system, are dysfunctional in autism spectrum disorders or schizophrenia. In sum, the impact that personality variables have on automatic imitation is less universal than initial reports suggest.

  10. Investigating the Relationship between Stable Personality Characteristics and Automatic Imitation.

    Directory of Open Access Journals (Sweden)

    Emily E Butler

    Full Text Available Automatic imitation is a cornerstone of nonverbal communication that fosters rapport between interaction partners. Recent research has suggested that stable dimensions of personality are antecedents to automatic imitation, but the empirical evidence linking imitation with personality traits is restricted to a few studies with modest sample sizes. Additionally, atypical imitation has been documented in autism spectrum disorders and schizophrenia, but the mechanisms underpinning these behavioural profiles remain unclear. Using a larger sample than prior studies (N=243, the current study tested whether performance on a computer-based automatic imitation task could be predicted by personality traits associated with social behaviour (extraversion and agreeableness and with disorders of social cognition (autistic-like and schizotypal traits. Further personality traits (narcissism and empathy were assessed in a subsample of participants (N=57. Multiple regression analyses showed that personality measures did not predict automatic imitation. In addition, using a similar analytical approach to prior studies, no differences in imitation performance emerged when only the highest and lowest 20 participants on each trait variable were compared. These data weaken support for the view that stable personality traits are antecedents to automatic imitation and that neural mechanisms thought to support automatic imitation, such as the mirror neuron system, are dysfunctional in autism spectrum disorders or schizophrenia. In sum, the impact that personality variables have on automatic imitation is less universal than initial reports suggest.

  11. Stable carbon isotope analyses of nanogram quantities of particulate organic carbon (pollen) with laser ablation nano combustion gas chromatography/isotope ratio mass spectrometry

    NARCIS (Netherlands)

    van Roij, Linda; Sluijs, Appy; Laks, Jelmer J.; Reichart, Gert-Jan

    2017-01-01

    Rationale: Analyses of stable carbon isotope ratios (δ13C values) of organic and inorganic matter remains have been instrumental for much of our understanding of present and past environmental and biological processes. Until recently, the analytical window of such analyses has been limited to

  12. Metabolic studies in man using stable isotopes

    International Nuclear Information System (INIS)

    Faust, H.; Jung, K.; Krumbiegel, P.

    1993-01-01

    In this project, stable isotope compounds and stable isotope pharmaceuticals were used (with emphasis on the application of 15 N) to study several aspects of nitrogen metabolism in man. Of the many methods available, the 15 N stable isotope tracer technique holds a special position because the methodology for application and nitrogen isotope analysis is proven and reliable. Valid routine methods using 15 N analysis by emission spectrometry have been demonstrated. Several methods for the preparation of biological material were developed during our participation in the Coordinated Research Programme. In these studies, direct procedures (i.e. use of diluted urine as a samples without chemical preparation) or rapid isolation methods were favoured. Within the scope of the Analytical Quality Control Service (AQCS) enriched stable isotope reference materials for medical and biological studies were prepared and are now available through the International Atomic Energy Agency. The materials are of special importance as the increasing application of stable isotopes as tracers in medical, biological and agricultural studies has focused interest on reliable measurements of biological material of different origin. 24 refs

  13. Stable Myoelectric Control of a Hand Prosthesis using Non-Linear Incremental Learning

    Directory of Open Access Journals (Sweden)

    Arjan eGijsberts

    2014-02-01

    Full Text Available Stable myoelectric control of hand prostheses remains an open problem. The only successful human-machine interface is surface electromyography, typically allowing control of a few degrees of freedom. Machine learning techniques may have the potential to remove these limitations, but their performance is thus far inadequate: myoelectric signals change over time under the influence of various factors, deteriorating control performance. It is therefore necessary, in the standard approach, to regularly retrain a new model from scratch.We hereby propose a non-linear incremental learning method in which occasional updates with a modest amount of novel training data allow continual adaptation to the changes in the signals. In particular, Incremental Ridge Regression and an approximation of the Gaussian Kernel known as Random Fourier Features are combined to predict finger forces from myoelectric signals, both finger-by-finger and grouped in grasping patterns.We show that the approach is effective and practically applicable to this problem by first analyzing its performance while predicting single-finger forces. Surface electromyography and finger forces were collected from 10 intact subjects during four sessions spread over two different days; the results of the analysis show that small incremental updates are indeed effective to maintain a stable level of performance.Subsequently, we employed the same method on-line to teleoperate a humanoid robotic arm equipped with a state-of-the-art commercial prosthetic hand. The subject could reliably grasp, carry and release everyday-life objects, enforcing stable grasping irrespective of the signal changes, hand/arm movements and wrist pronation and supination.

  14. Stable isotope research pool inventory

    International Nuclear Information System (INIS)

    1982-01-01

    This report contains a listing of electromagnetically separated stable isotopes which are available for distribution within the United States for nondestructive research use from the Oak Ridge National Laboratory on a loan basis. This inventory includes all samples of stable isotopes in the Material Research Collection and does not designate whether a sample is out on loan or in reprocessing. For some of the high abundance naturally occurring isotopes, larger amounts can be made available; for example, Ca-40 and Fe-56

  15. Microperimetry and fundus autofluorescence in diabetic macular edema: subthreshold micropulse diode laser versus modified early treatment diabetic retinopathy study laser photocoagulation.

    Science.gov (United States)

    Vujosevic, Stela; Bottega, Elisa; Casciano, Margherita; Pilotto, Elisabetta; Convento, Enrica; Midena, Edoardo

    2010-06-01

    The purpose of this study was to evaluate and compare microperimetry and fundus autofluorescence (FAF) after subthreshold micropulse diode laser versus modified Early Treatment Diabetic Retinopathy Study photocoagulation for clinically significant diabetic macular edema. A prospective randomized clinical trial including 62 eyes (50 patients) with untreated, center-involving, clinically significant diabetic macular edema was performed. All patients underwent best-corrected visual acuity determination (logarithm of the minimum angle of resolution), slit-lamp biomicroscopy, FAF, optical coherence tomography, microperimetry (macular sensitivity), and fluorescein angiography before and after treatment. Best-corrected visual acuity, optical coherence tomography, microperimetry, and FAF were repeated at 1-, 3-, 6-, 9-, and 12-month follow-up examinations. Fluorescein angiography was performed at baseline and at 6 and 12 months. Before treatment, demographic and macular parameters were not different between the two treatment groups. At 12 months, best-corrected visual acuity remained stable in both groups (P = 0.41 and P = 0.82), mean central retinal thickness decreased in both groups (P = 0.0002 and P autofluorescence never changed in the micropulse diode laser group even after retreatment. In the Early Treatment Diabetic Retinopathy Study group, FAF increased up to 9 months and decreased in 6 eyes (20%) at 12 months. Micropulse diode laser seems to be as effective as modified Early Treatment Diabetic Retinopathy Study laser photocoagulation in the treatment of clinically significant diabetic macular edema. Micropulse diode laser treatment does not determine any change on FAF showing (at least) nonclinically visible damage of the retinal pigment epithelium. Microperimetry data encourage the use of a new, less aggressive laser therapeutic approach in the treatment of clinically significant diabetic macular edema.

  16. Exact simulation of max-stable processes.

    Science.gov (United States)

    Dombry, Clément; Engelke, Sebastian; Oesting, Marco

    2016-06-01

    Max-stable processes play an important role as models for spatial extreme events. Their complex structure as the pointwise maximum over an infinite number of random functions makes their simulation difficult. Algorithms based on finite approximations are often inexact and computationally inefficient. We present a new algorithm for exact simulation of a max-stable process at a finite number of locations. It relies on the idea of simulating only the extremal functions, that is, those functions in the construction of a max-stable process that effectively contribute to the pointwise maximum. We further generalize the algorithm by Dieker & Mikosch (2015) for Brown-Resnick processes and use it for exact simulation via the spectral measure. We study the complexity of both algorithms, prove that our new approach via extremal functions is always more efficient, and provide closed-form expressions for their implementation that cover most popular models for max-stable processes and multivariate extreme value distributions. For simulation on dense grids, an adaptive design of the extremal function algorithm is proposed.

  17. Large-eddy simulation of stable atmospheric boundary layers to develop better turbulence closures for climate and weather models

    Science.gov (United States)

    Bou-Zeid, Elie; Huang, Jing; Golaz, Jean-Christophe

    2011-11-01

    A disconnect remains between our improved physical understanding of boundary layers stabilized by buoyancy and how we parameterize them in coarse atmospheric models. Most operational climate models require excessive turbulence mixing in such conditions to prevent decoupling of the atmospheric component from the land component, but the performance of such a model is unlikely to be satisfactory under weakly and moderately stable conditions. Using Large-eddy simulation, we revisit some of the basic challenges in parameterizing stable atmospheric boundary layers: eddy-viscosity closure is found to be more reliable due to an improved alignment of vertical Reynolds stresses and mean strains under stable conditions, but the dependence of the magnitude of the eddy viscosity on stability is not well represented by several models tested here. Thus, we propose a new closure that reproduces the different stability regimes better. Subsequently, tests of this model in the GFDL's single-column model (SCM) are found to yield good agreement with LES results in idealized steady-stability cases, as well as in cases with gradual and sharp changes of stability with time.

  18. An intermittent control model of flexible human gait using a stable manifold of saddle-type unstable limit cycle dynamics.

    Science.gov (United States)

    Fu, Chunjiang; Suzuki, Yasuyuki; Kiyono, Ken; Morasso, Pietro; Nomura, Taishin

    2014-12-06

    Stability of human gait is the ability to maintain upright posture during walking against external perturbations. It is a complex process determined by a number of cross-related factors, including gait trajectory, joint impedance and neural control strategies. Here, we consider a control strategy that can achieve stable steady-state periodic gait while maintaining joint flexibility with the lowest possible joint impedance. To this end, we carried out a simulation study of a heel-toe footed biped model with hip, knee and ankle joints and a heavy head-arms-trunk element, working in the sagittal plane. For simplicity, the model assumes a periodic desired joint angle trajectory and joint torques generated by a set of feed-forward and proportional-derivative feedback controllers, whereby the joint impedance is parametrized by the feedback gains. We could show that a desired steady-state gait accompanied by the desired joint angle trajectory can be established as a stable limit cycle (LC) for the feedback controller with an appropriate set of large feedback gains. Moreover, as the feedback gains are decreased for lowering the joint stiffness, stability of the LC is lost only in a few dimensions, while leaving the remaining large number of dimensions quite stable: this means that the LC becomes saddle-type, with a low-dimensional unstable manifold and a high-dimensional stable manifold. Remarkably, the unstable manifold remains of low dimensionality even when the feedback gains are decreased far below the instability point. We then developed an intermittent neural feedback controller that is activated only for short periods of time at an optimal phase of each gait stride. We characterized the robustness of this design by showing that it can better stabilize the unstable LC with small feedback gains, leading to a flexible gait, and in particular we demonstrated that such an intermittent controller performs better if it drives the state point to the stable manifold, rather

  19. Management of outpatients in France with stable coronary artery disease. Findings from the prospeCtive observational LongitudinAl RegIstry oF patients with stable coronary arterY disease (CLARIFY) registry.

    Science.gov (United States)

    Danchin, Nicolas; Ferrieres, Jean; Guenoun, Maxime; Cattan, Simon; Rushton-Smith, Sophie K; Greenlaw, Nicola; Ferrari, Roberto; Steg, Philippe Gabriel

    2014-01-01

    Improvements in the treatment of coronary artery disease mean that an increasing number of patients survive acute cardiovascular events and live as outpatients with or without anginal symptoms. To determine the characteristics and management of contemporary outpatients with stable coronary artery disease in Western Europe, and to compare France with the other Western European countries. CLARIFY (prospeCtive observational LongitudinAl RegIstry oF patients with stable coronary arterY disease) is an international, prospective, observational, longitudinal study. Between November 2009 and July 2010, 32,954 adult outpatients with stable coronary artery disease (defined as a history of documented myocardial infarction [of >3 months], prior coronary revascularization, chest pain with myocardial ischaemia, or coronary stenosis of>50% proven by angiography) were enrolled in 45 countries. The demographics and management of CLARIFY patients enrolled in France were compared with those enrolled in other Western European countries (Austria, Belgium, Denmark, Germany, Greece, Ireland, Italy, Netherlands, Portugal, Spain, Switzerland and the UK). Of the 14,726 patients enrolled in Western Europe (mean age 66.2 [10.2] years; 79.6% male), 2432 (16.5%) were from France. The use of aspirin was lower in France than in other Western European countries (74.5% vs. 86.9%, respectively), whereas use of thienopyridines (48.5% vs. 21.7%), oral anticoagulants (12.3% vs. 9.0%) and lipid-lowering drugs (95.8% vs. 92.5%) was higher. Beta-blockers were used in 73% of both groups. Angina was less prevalent in France (6.3% vs. 15.5%) and French patients showed higher levels of physical activity than their counterparts in Western Europe. The management of patients with stable CAD in France appears favourable, with good adherence to guideline-based therapies, but there remains room for improvement in terms of symptom and risk factor control. Copyright © 2014. Published by Elsevier Masson SAS.

  20. Benefit from autologous stem cell transplantation in primary refractory myeloma? Different outcomes in progressive versus stable disease

    Science.gov (United States)

    Rosiñol, Laura; García-Sanz, Ramón; Lahuerta, Juan José; Hernández-García, Miguel; Granell, Miquel; de la Rubia, Javier; Oriol, Albert; Hernández-Ruiz, Belén; Rayón, Consuelo; Navarro, Isabel; García-Ruiz, Juan Carlos; Besalduch, Joan; Gardella, Santiago; Jiménez, Javier López; Díaz-Mediavilla, Joaquín; Alegre, Adrián; Miguel, Jesús San; Bladé, Joan

    2012-01-01

    Background Several studies of autologous stem cell transplantation in primary refractory myeloma have produced encouraging results. However, the outcome of primary refractory patients with stable disease has not been analyzed separately from the outcome of patients with progressive disease. Design and Methods In the Spanish Myeloma Group 2000 trial, 80 patients with primary refractory myeloma (49 with stable disease and 31 with progressive disease), i.e. who were refractory to initial chemotherapy, were scheduled for tandem transplants (double autologous transplant or a single autologous transplant followed by an allogeneic transplant). Patients with primary refractory disease included those who never achieved a minimal response (≥25% M-protein decrease) or better. Responses were assessed using the European Bone Marrow Transplant criteria. Results There were no significant differences in the rates of partial response or better between patients with stable or progressive disease. However, 38% of the patients with stable disease at the time of transplantation remained in a stable condition or achieved a minimal response after transplantation versus 7% in the group with progressive disease (P=0.0017) and the rate of early progression after transplantation was significantly higher among the group with progressive disease at the time of transplantation (22% versus 2%; P=0.0043). After a median follow-up of 6.6 years, the median survival after first transplant of the whole series was 2.3 years. Progression-free and overall survival from the first transplant were shorter in patients with progressive disease (0.6 versus 2.3 years, P=0.00004 and 1.1 versus 6 years, P=0.00002, respectively). Conclusions Our results show that patients with progressive refractory myeloma do not benefit from autologous transplantation, while patients with stable disease have an outcome comparable to those with chemosensitive disease. (ClinicalTrials.gov:NCT00560053) PMID:22058223