WorldWideScience

Sample records for actively controlled flaps

  1. Active Control of Long Bridges Using Flaps

    DEFF Research Database (Denmark)

    Hansen, H. I.; Thoft-Christensen, Palle

    The main problem in designing ultra-long span suspension bridges is flutter. A solution to this problem might be to introduce an active flap control system to increase the flutter wind velocity. The investigated flap control system consists of flaps integrated in the bridge girder so each flap...... is the streamlined part of the edge of the girder. Additional aerodynamic derivatives are shown for the flaps and it is shown how methods already developed can be used to estimate the flutter wind velocity for a bridge section with flaps. As an example, the flutter wind velocity is calculated for different flap...... configurations for a bridge section model by using aerodynamic derivatives for a flat plate. The example shows that different flap configurations can either increase or decrease the flutter wind velocity. for optimal flap configurations flutter will not occur....

  2. Pivoting output unit control systems activated by jacks. [for controlling aircraft flaps

    Science.gov (United States)

    Belliere, P.

    1978-01-01

    An invention to be used for controlling aircraft flaps is described. It is applicable to control systems with two coaxial output units which pivot simultaneously with respect to two fixed units and which are activated by two opposed, straight coaxial jacks.

  3. Power performance optimization and loads alleviation with active flaps using individual flap control

    DEFF Research Database (Denmark)

    Pettas, Vasilis; Barlas, Athanasios; Gertz, Drew Patrick

    2016-01-01

    the sensor inputs. The AEP is increased due to the upscaling but also further due to the flap system while the fatigue loads in components of interest (blade, tower, nacelle and main bearing) are reduced close to the level of the original turbine. The aim of this study is to demonstrate a simple....... In an industrial-oriented manner the baseline rotor is upscaled by 5% and the ATEFs are implemented in the outer 30% of the blades. The flap system is kept simple and robust with a single flap section and control with wind speed, rotor azimuth, root bending moments and angle of attack in flap's mid-section being...

  4. Identification of Flap Motion Parameters for Vibration Reduction in Helicopter Rotors with Multiple Active Trailing Edge Flaps

    Directory of Open Access Journals (Sweden)

    Uğbreve;ur Dalli

    2011-01-01

    Full Text Available An active control method utilizing the multiple trailing edge flap configuration for rotorcraft vibration suppression and blade loads control is presented. A comprehensive model for rotor blade with active trailing edge flaps is used to calculate the vibration characteristics, natural frequencies and mode shapes of any complex composite helicopter rotor blade. A computer program is developed to calculate the system response, rotor blade root forces and moments under aerodynamic forcing conditions. Rotor blade system response is calculated using the proposed solution method and the developed program depending on any structural and aerodynamic properties of rotor blades, structural properties of trailing edge flaps and properties of trailing edge flap actuator inputs. Rotor blade loads are determined first on a nominal rotor blade without multiple active trailing edge flaps and then the effects of the active flap motions on the existing rotor blade loads are investigated. Multiple active trailing edge flaps are controlled by using open loop controllers to identify the effects of the actuator signal output properties such as frequency, amplitude and phase on the system response. Effects of using multiple trailing edge flaps on controlling rotor blade vibrations are investigated and some design criteria are determined for the design of trailing edge flap controller that will provide actuator signal outputs to minimize the rotor blade root loads. It is calculated that using the developed active trailing edge rotor blade model, helicopter rotor blade vibrations can be reduced up to 36% of the nominal rotor blade vibrations.

  5. Positioning the 5'-flap junction in the active site controls the rate of flap endonuclease-1-catalyzed DNA cleavage

    KAUST Repository

    Song, Bo

    2018-02-09

    Flap endonucleases catalyze cleavage of single-stranded DNA flaps formed during replication, repair and recombination, and are therefore essential for genome processing and stability. Recent crystal structures of DNA-bound human flap endonuclease (hFEN1) offer new insights into how conformational changes in the DNA and hFEN1 may facilitate the reaction mechanism. For example, previous biochemical studies of DNA conformation performed under non-catalytic conditions with Ca2+ have suggested that base unpairing at the 5\\'-flap:template junction is an important step in the reaction, but the new structural data suggest otherwise. To clarify the role of DNA changes in the kinetic mechanism, we measured a series of transient steps - from substrate binding to product release - during the hFEN1-catalyzed reaction in the presence of Mg2+. We found that while hFEN1 binds and bends DNA at a fast, diffusion-limited rate, much slower Mg2+-dependent conformational changes in DNA around the active site are subsequently necessary and rate-limiting for 5\\'-flap cleavage. These changes are reported overall by fluorescence of 2-aminopurine at the 5\\'-flap:template junction, indicating that local DNA distortion (e.g., disruption of base stacking observed in structures), associated with positioning the 5\\'-flap scissile phosphodiester bond in the hFEN1 active site, controls catalysis. hFEN1 residues with distinct roles in the catalytic mechanism, including those binding metal ions (Asp-34, Asp-181), steering the 5\\'-flap through the active site and binding the scissile phosphate (Lys-93, Arg-100), and stacking against the base 5\\' to the scissile phosphate (Tyr-40), all contribute to these rate-limiting conformational changes, ensuring efficient and specific cleavage of 5\\'-flaps.

  6. Positioning the 5'-flap junction in the active site controls the rate of flap endonuclease-1-catalyzed DNA cleavage

    KAUST Repository

    Song, Bo; Hamdan, Samir; Hingorani, Manju M

    2018-01-01

    Flap endonucleases catalyze cleavage of single-stranded DNA flaps formed during replication, repair and recombination, and are therefore essential for genome processing and stability. Recent crystal structures of DNA-bound human flap endonuclease (hFEN1) offer new insights into how conformational changes in the DNA and hFEN1 may facilitate the reaction mechanism. For example, previous biochemical studies of DNA conformation performed under non-catalytic conditions with Ca2+ have suggested that base unpairing at the 5'-flap:template junction is an important step in the reaction, but the new structural data suggest otherwise. To clarify the role of DNA changes in the kinetic mechanism, we measured a series of transient steps - from substrate binding to product release - during the hFEN1-catalyzed reaction in the presence of Mg2+. We found that while hFEN1 binds and bends DNA at a fast, diffusion-limited rate, much slower Mg2+-dependent conformational changes in DNA around the active site are subsequently necessary and rate-limiting for 5'-flap cleavage. These changes are reported overall by fluorescence of 2-aminopurine at the 5'-flap:template junction, indicating that local DNA distortion (e.g., disruption of base stacking observed in structures), associated with positioning the 5'-flap scissile phosphodiester bond in the hFEN1 active site, controls catalysis. hFEN1 residues with distinct roles in the catalytic mechanism, including those binding metal ions (Asp-34, Asp-181), steering the 5'-flap through the active site and binding the scissile phosphate (Lys-93, Arg-100), and stacking against the base 5' to the scissile phosphate (Tyr-40), all contribute to these rate-limiting conformational changes, ensuring efficient and specific cleavage of 5'-flaps.

  7. Active Control of Separation From the Flap of a Supercritical Airfoil

    Science.gov (United States)

    Melton, LaTunia Pack; Yao, Chung-Sheng; Seifert, Avi

    2006-01-01

    Zero-mass-flux periodic excitation was applied at several regions on a simplified high-lift system to delay the occurrence of flow separation. The NASA Energy Efficient Transport (EET) supercritical airfoil was equipped with a 15% chord simply hinged leading edge flap and a 25% chord simply hinged trailing edge flap. Detailed flow features were measured in an attempt to identify optimal actuator placement. The measurements included steady and unsteady model and tunnel wall pressures, wake surveys, arrays of surface hot-films, flow visualization, and particle image velocimetry (PIV). The current paper describes the application of active separation control at several locations on the deflected trailing edge flap. High frequency (F(+) approximately equal to 10) and low frequency amplitude modulation (F(+) sub AM approximately equal to 1) of the high frequency excitation were used for control. It was noted that the same performance gains were obtained with amplitude modulation and required only 30% of the momentum input required by pure sine excitation.

  8. A smart rotor configuration with linear quadratic control of adaptive trailing edge flaps for active load alleviation

    DEFF Research Database (Denmark)

    Bergami, Leonardo; Poulsen, Niels Kjølstad

    2015-01-01

    The paper proposes a smart rotor configuration where adaptive trailing edge flaps (ATEFs) are employed for active alleviation of the aerodynamic loads on the blades of the NREL 5 MW reference turbine. The flaps extend for 20% of the blade length and are controlled by a linear quadratic (LQ....... The effects of active flap control are assessed with aeroelastic simulations of the turbine in normal operation conditions, as prescribed by the International Electrotechnical Commission standard. The turbine lifetime fatigue damage equivalent loads provide a convenient summary of the results achieved...

  9. Suspension Bridge Flutter for Girder with Separate Control Flaps

    DEFF Research Database (Denmark)

    Huynh, T.; Thoft-Christensen, Palle

    Active vibration control of long span suspension bridge flutter using separated control flaps (SFSC) has shown to increase effectively the critical wind speed of bridges. In this paper, an SFSC calculation based on modal equations of the vertical and torsional motions of the bridge girder including...... the flaps is presented. The length of the flaps attached to the girder, the flap configuration and the flap rotational angles are parameters used to increase the critical wind speed of the bridge. To illustrate the theory a numerical example is shown for a suspension bridge of 1000m+2500m+1000m span based...... on the Great Belt Bridge streamlined girder....

  10. Structural and mechanism design of an active trailing-edge flap blade

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hwan [Samsung Techwin R and D Center, Seongnam (Korea, Republic of); Natarajan, Balakumaran; Eun, Won Jong; Shin, Sang Joon [Seoul National University, Seoul (Korea, Republic of); R, Viswamurthy S. [National Aerospace Laboratories, Bangalore (India); Park, Jae Sang [Agency for Defense Development, Daejeon (Korea, Republic of); Kim, Tae Song [Technical University of Denmark, Risoe Campus, Roskilde (Denmark)

    2013-09-15

    A conventional rotor control system restricted at 1/rev frequency component is unable to vary the hub vibratory loads and the aero acoustic noise, which exist in high frequency components. Various active rotor control methodologies have been examined in the literature to alleviate the problem of excessive hub vibratory loads and noise. The active control device manipulates the blade pitch angle with arbitrary higher harmonic frequencies individually. In this paper, an active trailing-edge flap blade, which is one of the active control methods, is developed to reduce vibratory loads and noise of the rotor through modification of unsteady aerodynamic loads. Piezoelectric actuators installed inside the blade manipulate the motion of the trailing edge flap. The proposed blade rotates at higher speed and additional structures are included to support the actuators and the flap. This improves the design, as the blade is able to withstand increased centrifugal force. The cross-section of the active blade is designed first. A stress/strain recovery analysis is then conducted to verify its structural integrity. A one-dimensional beam analysis is also carried out to assist with the construction of the fan diagram. To select the actuator and design the flap actuation region, the flap hinge moment is estimated via a CFD analysis. To obtain the desired flap deflection of ±4 .deg. , three actuators are required. The design of the flap actuation region is validated using a test bed with a skin hinge. However, because the skin hinge induces additional flap hinge moment, it does not provide sufficient deflection angle. Therefore, the flap hinge is replaced by a pin-type hinge, and the results are evaluated.

  11. Identification of Flap Motion Parameters for Vibration Reduction in Helicopter Rotors with Multiple Active Trailing Edge Flaps

    OpenAIRE

    Dalli, Uğbreve;ur; Yüksel, Şcedilefaatdin

    2011-01-01

    An active control method utilizing the multiple trailing edge flap configuration for rotorcraft vibration suppression and blade loads control is presented. A comprehensive model for rotor blade with active trailing edge flaps is used to calculate the vibration characteristics, natural frequencies and mode shapes of any complex composite helicopter rotor blade. A computer program is developed to calculate the system response, rotor blade root forces and moments under aerodynamic forcing condit...

  12. Active Control of Suspension Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    In this paper some recent research on active control of very long suspension bridges, is presented. The presentation is based on research work at Aalborg University, Denmark. The active control system is based on movable flaps attached to the bridge girder. Wind load on bridges with or without...... flaps attached to the girder is briefly presented. A simple active control system is discussed. Results from wind tunnel experiments with a bridge section show that flaps can be used effectively to control bridge girder vibrations. Flutter conditions for suspension bridges with and without flaps...

  13. Management of Vortices Trailing Flapped Wings via Separation Control

    Science.gov (United States)

    Greenblatt, David

    2005-01-01

    A pilot study was conducted on a flapped semi-span model to investigate the concept and viability of near-wake vortex management via separation control. Passive control was achieved by means of a simple fairing and active control was achieved via zero mass-flux blowing slots. Vortex sheet strength, estimated by integrating surface pressure ports, was used to predict vortex characteristics by means of inviscid rollup relations. Furthermore, vortices trailing the flaps were mapped using a seven-hole probe. Separation control was found to have a marked effect on vortex location, strength, tangential velocity, axial velocity and size over a wide range of angles of attack and control conditions. In general, the vortex trends were well predicted by the inviscid rollup relations. Manipulation of the separated flow near the flap edges exerted significant control over both outboard and inboard edge vortices while producing negligible lift excursions. Dynamic separation and attachment control was found to be an effective means for dynamically perturbing the vortex from arbitrarily long wavelengths down to wavelengths less than a typical wingspan. In summary, separation control has the potential for application to time-independent or time-dependent wake alleviation schemes, where the latter can be deployed to minimize adverse effects on ride-quality and dynamic structural loading.

  14. Stability investigation of an airfoil section with active flap control

    DEFF Research Database (Denmark)

    Bergami, Leonardo; Gaunaa, Mac

    2010-01-01

    function approximation. Stability of the full aeroservoelastic system is determined through eigenvalue analysis by state-space formulation of the indicial approximation. Validation is carried out against an implementation of the recursive method by Theodorsen and Garrick for flexure-torsion-aileron flutter...... for fatigue load alleviation. The structural model of the 2-D airfoil section contains three degrees of freedom: heave translation, pitch rotation and flap deflection. A potential flow model provides the aerodynamic forces and their distribution. The unsteady aerodynamics are described using an indicial...... on measurements of either heave displacement, local angle of attack or aerodynamic pressure difference measured over the airfoil. The purpose of the controlled deformable flap is to reduce fluctuations in the aerodynamic forces on the airfoil, which, according to recent studies, have a significant potential...

  15. Local correlations for flap gap oscillatory blowing active flow control technology

    Directory of Open Access Journals (Sweden)

    Cătălin NAE

    2010-09-01

    Full Text Available Active technology for oscillatory blowing in the flap gap has been tested at INCAS subsonic wind tunnel in order to evaluate this technology for usage in high lift systems with active flow control. The main goal for this investigation was to validate TRL level 4 for this technology and to extend towards flight testing. CFD analysis was performed in order to identify local correlations with experimental data and to better formulate a design criteria so that a maximum increase in lift is possible under given geometrical constraints. Reference to a proposed metric for noise evaluation is also given. This includes basic 2D flow cases and also 2.5D configurations. In 2.5D test cases this work has been extended so that the proposed system may be selected as a mature technology in the JTI Clean Sky, Smart Fixed Wing Aircraft ITD. Complex post-processing of the experimental and CFD data was mainly oriented towards system efficiency and TRL evaluation for this active technology.

  16. Adaptive trailing edge flaps for active load alleviation in a smart rotor configuration

    Energy Technology Data Exchange (ETDEWEB)

    Bergami, L.

    2013-08-15

    The work investigates the development of an active smart rotor concept from an aero-servo-elastic perspective. An active smart rotor is a wind turbine rotor that, through a combination of sensors, control units and actuators, is able to alleviate the fluctuating part of the aerodynamic loads it has to withstand. The investigation focuses on a specific actuator type: the Adaptive Trailing Edge Flap (ATEF), which introduces a continuous deformation of the aft part of the airfoil camber-line. An aerodynamic model that accounts for the steady and unsteady effects of the flap deflection on a 2D airfoil section is developed, and, considering both attached and separated flow conditions, is validated by comparison against Computational Fluid Dynamic solutions and a panel code method. The aerodynamic model is integrated in the BEM-based aeroelastic simulation code HAWC2, thus providing a tool able to simulate the response of a wind turbine equipped with ATEF. A load analysis of the NREL 5 MW reference turbine in its baseline configuration reveals that the highest contribution to the blade flapwise fatigue damage originates from normal operation above rated wind speed, and from loads characterized by frequencies below 1 Hz. The analysis also reports that periodic load variations on the turbine blade account for nearly 11 % of the blade flapwise lifetime fatigue damage, while the rest is ascribed to load variations from disturbances of stochastic nature. The study proposes a smart rotor configuration with flaps laid out on the outer 20 % of the blade span, from 77 % to 97% of the blade length. The configuration is first tested with a simplified cyclic control approach, which gives a preliminary indication of the load alleviation potential, and also reveals the possibility to enhance the rotor energy capture below rated conditions by using the flaps. Two model based control algorithms are developed to actively alleviate the fatigue loads on the smart rotor with ATEF. The first

  17. Closed-Loop Control of Constrained Flapping Wing Micro Air Vehicles

    Science.gov (United States)

    2014-03-27

    predicts forces and moments for the class of flapping wing fliers that makes up most insects and hummingbirds. Large bird and butterfly “clap- and...Closed-Loop Control of Constrained Flapping Wing Micro Air Vehicles DISSERTATION Garrison J. Lindholm, Captain, USAF AFIT-ENY-DS-14-M-02 DEPARTMENT...States Air Force, Department of Defense, or the United States Government. AFIT-ENY-DS-14-M-02 Closed-Loop Control of Constrained Flapping Wing Micro Air

  18. Model predictive control of trailing edge flaps on a wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Castaignet, D.B.

    2011-11-15

    Trailing edge flaps on wind turbine blades have been investigated for several years. Aero-servoelastic simulations carried out with different simulation tools, trailing edge flaps configurations and controller designs proved that trailing edge flaps are a suitable solution for reducing some of the wind turbine fatigue and extreme loads. This potential was confirmed with wind tunnel tests made on blade sections with trailing edge flaps and on a scaled two-bladed wind turbine in a wind tunnel. The work presented in this thesis includes a full-scale test run on a Vestas V27 wind turbine equipped with three trailing edge flaps on one blade, located on DTU's Risoe Campus in Roskilde, Denmark. This thesis is divided into three parts: the controller design, results from simulations, and results from the experiments. The trailing edge flaps controller designed for this project is based on a frequency-weighted model predictive control, tuned in order to target only the flapwise blade root loads at the frequencies contributing the most to blade root fatigue damage (the 1P, 2P and 3P frequencies), and to avoid unnecessary wear and tear of the actuators at high frequencies. A disturbance model consisting in periodic disturbances at the rotor speed harmonic frequencies and a quasi-steady input disturbance is aggregated to an analytical model of a spinning blade with trailing edge flaps. Simulations on a multi-megawatt wind turbine show the potential of the trailing edge flaps to reduce the flapwise blade root fatigue loads by 23%, but also the main shaft and the tower fatigue loads by up to 32%. Extreme loads during normal production also benefit from the trailing edge flaps. At last, the same controller was run on the Vestas V27 wind turbine located at the Risoe Campus of the Technical University of Denmark, in Roskilde, Denmark. One blade of the turbine was equipped with three independent trailing edge flaps. In spite of the failure of several sensors and actuators, the

  19. Full-scale test of trailing edge flaps on a Vestas V27 wind turbine: active load reduction and system identification

    DEFF Research Database (Denmark)

    Castaignet, Damien; Barlas, Thanasis K.; Buhl, Thomas

    2014-01-01

    model, from trailing edge flap angle to flapwise blade root moment, was derived and compared with the linear analytical model used in the model predictive control design model. Flex5 simulations run with the same model predictive control showed a good correlation between the simulations......A full-scale test was performed on a Vestas V27 wind turbine equipped with one active 70 cm long trailing edge flap on one of its 13 m long blades. Active load reduction could be observed in spite of the limited spanwise coverage of the single active trailing edge flap. A frequency-weighted model...

  20. Human exonuclease 1 (EXO1) activity characterization and its function on FLAP structures

    DEFF Research Database (Denmark)

    Keijzers, Guido; Bohr, Vilhelm A; Juel Rasmussen, Lene

    2015-01-01

    structures, we determined factors essential for the thermodynamic stability of EXO1. We show that enzymatic activity and stability of EXO1 on DNA is modulated by temperature. By characterization of EXO1 flap activity using various DNA flap substrates, we show that EXO1 has a strong capacity for degrading...... double stranded DNA and has a modest endonuclease or 5' flap activity. Furthermore, we report novel mechanistic insights into the processing of flap structures, showing that EXO1 preferentially cleaves one nucleotide inwards in a double stranded region of a forked and nicked DNA flap substrates...

  1. Extreme load alleviation using industrial implementation of active trailing edge flaps in a full design load basis

    DEFF Research Database (Denmark)

    Barlas, Athanasios; Pettas, Vasilis; Gertz, Drew Patrick

    2016-01-01

    The application of active trailing edge flaps in an industrial oriented implementation is evaluated in terms of capability of alleviating design extreme loads. A flap system with basic control functionality is implemented and tested in a realistic full Design Load Basis (DLB) for the DTU 10MW...

  2. Variable Camber Continuous Aerodynamic Control Surfaces and Methods for Active Wing Shaping Control

    Science.gov (United States)

    Nguyen, Nhan T. (Inventor)

    2016-01-01

    An aerodynamic control apparatus for an air vehicle improves various aerodynamic performance metrics by employing multiple spanwise flap segments that jointly form a continuous or a piecewise continuous trailing edge to minimize drag induced by lift or vortices. At least one of the multiple spanwise flap segments includes a variable camber flap subsystem having multiple chordwise flap segments that may be independently actuated. Some embodiments also employ a continuous leading edge slat system that includes multiple spanwise slat segments, each of which has one or more chordwise slat segment. A method and an apparatus for implementing active control of a wing shape are also described and include the determination of desired lift distribution to determine the improved aerodynamic deflection of the wings. Flap deflections are determined and control signals are generated to actively control the wing shape to approximate the desired deflection.

  3. Extreme load alleviation using industrial implementation of active trailing edge flaps in a full design load basis

    OpenAIRE

    Barlas, Athanasios; Pettas, Vasilis; Gertz, Drew Patrick; Aagaard Madsen , Helge

    2016-01-01

    The application of active trailing edge flaps in an industrial oriented implementation is evaluated in terms of capability of alleviating design extreme loads. A flap system with basic control functionality is implemented and tested in a realistic full Design Load Basis (DLB) for the DTU 10MW Reference Wind Turbine (RWT) model and for an upscaled rotor version in DTU's aeroelastic code HAWC2. The flap system implementation shows considerable potential in reducing extreme loads in components o...

  4. Localized, Non-Harmonic Active Flap Motions for Low Frequency In-Plane Rotor Noise Reduction

    Science.gov (United States)

    Sim, Ben W.; Potsdam, Mark; Kitaplioglu, Cahit; LeMasurier, Philip; Lorber, Peter; Andrews, Joseph

    2012-01-01

    A first-of-its-kind demonstration of the use of localized, non-harmonic active flap motions, for suppressing low frequency, in-plane rotor noise, is reported in this paper. Operational feasibility is verified via testing of the full-scale AATD/Sikorsky/UTRC active flap demonstration rotor in the NFAC's 40- by 80-Foot anechoic wind tunnel. Effectiveness of using localized, non-harmonic active flap motions are compared to conventional four-per-rev harmonic flap motions, and also active flap motions derived from closed-loop acoustics implementations. All three approaches resulted in approximately the same noise reductions over an in-plane three-by-three microphone array installed forward and near in-plane of the rotor in the nearfield. It is also reported that using an active flap in this localized, non-harmonic manner, resulted in no more that 2% rotor performance penalty, but had the tendency to incur higher hub vibration levels.

  5. Deformable trailing edge flaps for modern megawatt wind turbine controllers using strain gauge sensors

    DEFF Research Database (Denmark)

    Andersen, Peter Bjørn; Henriksen, Lars Christian; Gaunaa, Mac

    2010-01-01

    . By enabling the trailing edge to move independently and quickly along the spanwise position of the blade, local small flutuations in the aerodynamic forces can be alleviated by deformation of the airfoil flap. Strain gauges are used as input for the flap controller, and the effect of placing strain gauges......The present work contains a deformable trailing edge flap controller integrated in a numerically simulated modern, variablespeed, pitch-regulated megawatt (MW)-size wind turbine. The aeroservoelastic multi-body code HAWC2 acts as a component in the control loop design. At the core of the proposed...... edge flaps on a wind turbine blade rather than a conclusive control design with traditional issues like stability and robustness fully investigated. Recent works have shown that the fatigue load reduction by use of trailing edge flaps may be greater than for traditional pitch control methods...

  6. Frequency-Weighted Model Predictive Control of Trailing Edge Flaps on a Wind Turbine Blade

    DEFF Research Database (Denmark)

    Castaignet, Damien; Couchman, Ian; Poulsen, Niels Kjølstad

    2013-01-01

    flapwise blade root moment and trailing edge flap deflection. Frequency-weighted MPC is chosen for its ability to handle constraints on the trailing edge flaps deflection, and to target at loads with given frequencies only. The controller is first tested in servo-aeroelastic simulations, before being......This paper presents the load reduction achieved with trailing edge flaps during a full-scale test on a Vestas V27 wind turbine. The trailing edge flap controller is a frequency-weighted linear model predictive control (MPC) where the quadratic cost consists of costs on the zero-phase filtered...

  7. Development of a Wind Turbine Test Rig and Rotor for Trailing Edge Flap Investigation: Static Flap Angles Case

    International Nuclear Information System (INIS)

    Abdelrahman, Ahmed; Johnson, David A

    2014-01-01

    One of the strategies used to improve performance and increase the life-span of wind turbines is active flow control. It involves the modification of the aerodynamic characteristics of a wind turbine blade by means of moveable aerodynamic control surfaces. Trailing edge flaps are relatively small moveable control surfaces placed at the trailing edge of a blade's airfoil that modify the lift of a blade or airfoil section. An instrumented wind turbine test rig and rotor were specifically developed to enable a wide-range of experiments to investigate the potential of trailing edge flaps as an active control technique. A modular blade based on the S833 airfoil was designed to allow accurate instrumentation and customizable settings. The blade is 1.7 meters long, had a constant 178mm chord and a 6° pitch. The modular aerodynamic parts were 3D printed using plastic PC-ABS material. The blade design point was within the range of wind velocities in the available large test facility. The wind facility is a large open jet wind tunnel with a maximum velocity of 11m/s in the test area. The capability of the developed system was demonstrated through an initial study of the effect of stationary trailing edge flaps on blade load and performance. The investigation focused on measuring the changes in flapwise bending moment and power production for different trailing edge flap spanwise locations and deflection angles. The relationship between the load reduction and deflection angle was linear as expected from theory and the highest reduction was caused by the flap furthest from the rotor center. Overall, the experimental setup proved to be effective in measuring small changes in flapwise bending moment within the wind turbine blade and will provide insight when (active) flap control is targeted

  8. Neuroinspired control strategies with applications to flapping flight

    Science.gov (United States)

    Dorothy, Michael Ray

    This dissertation is centered on a theoretical, simulation, and experimental study of control strategies which are inspired by biological systems. Biological systems, along with sufficiently complicated engineered systems, often have many interacting degrees of freedom and need to excite large-displacement oscillations in order to locomote. Combining these factors can make high-level control design difficult. This thesis revolves around three different levels of abstraction, providing tools for analysis and design. First, we consider central pattern generators (CPGs) to control flapping-flight dynamics. The key idea here is dimensional reduction - we want to convert complicated interactions of many degrees of freedom into a handful of parameters which have intuitive connections to the overall system behavior, leaving the control designer unconcerned with the details of particular motions. A rigorous mathematical and control theoretic framework to design complex three-dimensional wing motions is presented based on phase synchronization of nonlinear oscillators. In particular, we show that flapping-flying dynamics without a tail or traditional aerodynamic control surfaces can be effectively controlled by a reduced set of central pattern generator parameters that generate phase-synchronized or symmetry-breaking oscillatory motions of two main wings. Furthermore, by using a Hopf bifurcation, we show that tailless aircraft (inspired by bats) alternating between flapping and gliding can be effectively stabilized by smooth wing motions driven by the central pattern generator network. Results of numerical simulation with a full six-degree-of-freedom flight dynamic model validate the effectiveness of the proposed neurobiologically inspired control approach. Further, we present experimental micro aerial vehicle (MAV) research with low-frequency flapping and articulated wing gliding. The importance of phase difference control via an abstract mathematical model of central

  9. Model predictive control of trailing edge flaps on a wind turbine blade

    DEFF Research Database (Denmark)

    Castaignet, Damien Bruno

    of the wind turbine fatigue and extreme loads. This potential was confirmed with wind tunnel tests made on blade sections with trailing edge flaps and on a scaled two-bladed wind turbine in a wind tunnel. The work presented in this thesis includes a full-scale test run on a Vestas V27 wind turbine equipped...... fatigue loads by 23%, but also the main shaft and the tower fatigue loads by up to 32%. Extreme loads during normal production also benefit from the trailing edge flaps. At last, the same controller was run on the Vestas V27 wind turbine located at the Risø Campus of the Technical University of Denmark......Trailing edge flaps on wind turbine blades have been investigated for several years. Aero-servoelastic simulations carried out with different simulation tools, trailing edge flaps configurations and controller designs proved that trailing edge flaps are a suitable solution for reducing some...

  10. Model Predictive Control of Trailing Edge Flaps on a wind turbine blade

    DEFF Research Database (Denmark)

    Castaignet, Damien; Poulsen, Niels Kjølstad; Buhl, Thomas

    2011-01-01

    Trailing Edge Flaps on wind turbine blades have been studied in order to achieve fatigue load reduction on the turbine components. We show in this paper how Model Predictive Control can be used to do frequency weighted control of the trailing edge flaps in order to reduce fatigue damage on the bl...

  11. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME THREE: MARKET & TEAM

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  12. Machine Learning for Flapping Wing Flight Control

    NARCIS (Netherlands)

    Goedhart, Menno; van Kampen, E.; Armanini, S.F.; de Visser, C.C.; Chu, Q.

    2018-01-01

    Flight control of Flapping Wing Micro Air Vehicles is challenging, because of their complex dynamics and variability due to manufacturing inconsistencies. Machine Learning algorithms can be used to tackle these challenges. A Policy Gradient algorithm is used to tune the gains of a

  13. Structural and mechanism design of an active trailing-edge flap blade

    DEFF Research Database (Denmark)

    Lee, Jae Hwan; Natarajan, Balakumaran; Eun, Won Jong

    2013-01-01

    , as the blade is able to withstand increased centrifugal force. The cross-section of the active blade is designed first. A stress/strain recovery analysis is then conducted to verify its structural integrity. A one-dimensional beam analysis is also carried out to assist with the construction of the fan diagram...... of the rotor through modification of unsteady aerodynamic loads. Piezoelectric actuators installed inside the blade manipulate the motion of the trailing edge flap. The proposed blade rotates at higher speed and additional structures are included to support the actuators and the flap. This improves the design....... To select the actuator and design the flap actuation region, the flap hinge moment is estimated via a CFD analysis. To obtain the desired flap deflection of ±4°, three actuators are required. The design of the flap actuation region is validated using a test bed with a skin hinge. However, because the skin...

  14. Curative effect observation of n-flap and off-flap EPi-LASIK in ametropia

    Directory of Open Access Journals (Sweden)

    Chao Liu

    2015-11-01

    Full Text Available AIM:To observe the clinical effect of on-flap and off-flap epipolis laser in situ keratomileusis(EPi-LASIKin ametropia.METHODS: Sixty-eight myopia patients(136 eyesreceiving surgical treatment were selected and divided into research group and control group according to different therapies. The patients in research group adopted off-flap EPi-LASIK and those in control group adopted on-flap EPi-LASIK. The index like uncorrected visual acuity, diopter and Haze of two groups before surgery, 1wk, 1 and 4mo after surgery was observed. RESULTS: One month after surgery, the uncorrected visual acuity of research group was 1.33±0.22 while that of control group was 1.22±0.19(PPPCONCLUSION:On-flap and off-flap EPi-LASIK are safe and effective surgery approaches in the clinical treatment of ametropia. The presence of corneal epithelial flap has a certain effect in the postoperative clinical outcome at early stage. The impact will be gradually reduced over time.

  15. A Single Amino Acid Difference between Mouse and Human 5-Lipoxygenase Activating Protein (FLAP) Explains the Speciation and Differential Pharmacology of Novel FLAP Inhibitors.

    Science.gov (United States)

    Blevitt, Jonathan M; Hack, Michael D; Herman, Krystal; Chang, Leon; Keith, John M; Mirzadegan, Tara; Rao, Navin L; Lebsack, Alec D; Milla, Marcos E

    2016-06-10

    5-Lipoxygenase activating protein (FLAP) plays a critical role in the metabolism of arachidonic acid to leukotriene A4, the precursor to the potent pro-inflammatory mediators leukotriene B4 and leukotriene C4 Studies with small molecule inhibitors of FLAP have led to the discovery of a drug binding pocket on the protein surface, and several pharmaceutical companies have developed compounds and performed clinical trials. Crystallographic studies and mutational analyses have contributed to a general understanding of compound binding modes. During our own efforts, we identified two unique chemical series. One series demonstrated strong inhibition of human FLAP but differential pharmacology across species and was completely inactive in assays with mouse or rat FLAP. The other series was active across rodent FLAP, as well as human and dog FLAP. Comparison of rodent and human FLAP amino acid sequences together with an analysis of a published crystal structure led to the identification of amino acid residue 24 in the floor of the putative binding pocket as a likely candidate for the observed speciation. On that basis, we tested compounds for binding to human G24A and mouse A24G FLAP mutant variants and compared the data to that generated for wild type human and mouse FLAP. These studies confirmed that a single amino acid mutation was sufficient to reverse the speciation observed in wild type FLAP. In addition, a PK/PD method was established in canines to enable preclinical profiling of mouse-inactive compounds. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  16. Blade-Mounted Flap Control for BVI Noise Reduction Proof-of-Concept Test

    Science.gov (United States)

    Dawson, Seth; Hassan, Ahmed; Straub, Friedrich; Tadghighi, Hormoz

    1995-01-01

    This report describes a wind tunnel test of the McDonnell Douglas Helicopter Systems (MDHS) Active Flap Model Rotor at the NASA Langley 14- by 22-Foot Subsonic Tunnel. The test demonstrated that BVI noise reductions and vibration reductions were possible with the use of an active flap. Aerodynamic results supported the acoustic data trends, showing a reduction in the strength of the tip vortex with the deflection of the flap. Acoustic results showed that the flap deployment, depending on the peak deflection angle and azimuthal shift in its deployment schedule, can produce BVI noise reductions as much as 6 dB on the advancing and retreating sides. The noise reduction was accompanied by an increase in low frequency harmonic noise and high frequency broadband noise. A brief assessment of the effect of the flap on vibration showed that significant reductions were possible. The greatest vibration reductions (as much as 76%) were found in the four per rev pitching moment at the hub. Performance improvement cam results were inconclusive, as the improvements were predicted to be smaller than the resolution of the rotor balance.

  17. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME ONE: PRELIMINARY DESIGN REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.; Chow, Ray [Zimitar, Inc.; Nordenholz, Thomas R. [The California Maritime Academy; Wamble, John Lee [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  18. Parametric study of fluid flow manipulation with piezoelectric macrofiber composite flaps

    Science.gov (United States)

    Sadeghi, O.; Tarazaga, P.; Stremler, M.; Shahab, S.

    2017-04-01

    Active Fluid Flow Control (AFFC) has received great research attention due to its significant potential in engineering applications. It is known that drag reduction, turbulence management, flow separation delay and noise suppression through active control can result in significantly increased efficiency of future commercial transport vehicles and gas turbine engines. In microfluidics systems, AFFC has mainly been used to manipulate fluid passing through the microfluidic device. We put forward a conceptual approach for fluid flow manipulation by coupling multiple vibrating structures through flow interactions in an otherwise quiescent fluid. Previous investigations of piezoelectric flaps interacting with a fluid have focused on a single flap. In this work, arrays of closely-spaced, free-standing piezoelectric flaps are attached perpendicular to the bottom surface of a tank. The coupling of vibrating flaps due to their interacting with the surrounding fluid is investigated in air (for calibration) and under water. Actuated flaps are driven with a harmonic input voltage, which results in bending vibration of the flaps that can work with or against the flow-induced bending. The size and spatial distribution of the attached flaps, and the phase and frequency of the input actuation voltage are the key parameters to be investigated in this work. Our analysis will characterize the electrohydroelastic dynamics of active, interacting flaps and the fluid motion induced by the system.

  19. Method and apparatus for controlling pitch and flap angles of a wind turbine

    Science.gov (United States)

    Deering, Kenneth J [Seattle, WA; Wohlwend, Keith P [Issaquah, WA

    2009-05-12

    A wind turbine with improved response to wind conditions is provided. Blade flap angle motion is accompanied by a change in pitch angle by an amount defining a pitch/flap coupling ratio. The coupling ratio is non-constant as a function of a flap angle and is preferably a substantially continuous, non-linear function of flap angle. The non-constant coupling ratio can be provided by mechanical systems such as a series of linkages or by configuring electronic or other control systems and/or angle sensors. A link with a movable proximal end advantageously is part of the mechanical system. The system can provide relatively large coupling ratios and relatively large rates of coupling ratio changes especially for near-feather pitches and low flap angles.

  20. Attitude control system for a lightweight flapping wing MAV.

    Science.gov (United States)

    Tijmons, Sjoerd; Karásek, Matěj; de Croon, G C H E

    2018-03-14

    Robust attitude control is an essential aspect of research on autonomous flight of flapping wing Micro Air Vehicles. The mechanical solutions by which the necessary control moments are realised come at the price of extra weight and possible loss of aerodynamic efficiency. Stable flight of these vehicles has been shown by several designs using a conventional tail, but also by tailless designs that use active control of the wings. In this study a control mechanism is proposed that provides active control over the wings. The mechanism improves vehicle stability and agility by generation of control moments for roll, pitch and yaw. Its effectiveness is demonstrated by static measurements around all the three axes. Flight test results confirm that the attitude of the test vehicle, including a tail, can be successfully controlled in slow forward flight conditions. Furthermore, the flight envelope is extended with robust hovering and the ability to reverse the flight direction using a small turn space. This capability is very important for autonomous flight capabilities such as obstacle avoidance. Finally, it is demonstrated that the proposed control mechanism allows for tailless hovering flight. © 2018 IOP Publishing Ltd.

  1. Primary control of a Mach scale swashplateless rotor using brushless DC motor actuated trailing edge flaps

    Science.gov (United States)

    Saxena, Anand

    The focus of this research was to demonstrate a four blade rotor trim in forward flight using integrated trailing edge flaps instead of using a swashplate controls. A compact brushless DC motor was evaluated as an on-blade actuator, with the possibility of achieving large trailing edge flap amplitudes. A control strategy to actuate the trailing edge flap at desired frequency and amplitude was developed and large trailing edge flap amplitudes from the motor (instead of rotational motion) were obtained. Once the actuator was tested on the bench-top, a lightweight mechanism was designed to incorporate the motor in the blade and actuate the trailing edge flaps. A six feet diameter, four bladed composite rotor with motor-flap system integrated into the NACA 0012 airfoil section was fabricated. Systematic testing was carried out for a range of load conditions, first in the vacuum chamber followed by hover tests. Large trailing edge flap deflections were observed during the hover testing, and a peak to peak trailing edge flap amplitude of 18 degree was achieved at 2000 rotor RPM with hover tip Mach number of 0.628. A closed loop controller was designed to demonstrate trailing edge flap mean position and the peak to peak amplitude control. Further, a soft pitch link was designed and fabricated, to replace the stiff pitch link and thereby reduce the torsional stiffness of the blade to 2/rev. This soft pitch link allowed for blade root pitch motion in response to the trailing edge flap inputs. Blade pitch response due to both steady as well as sinusoidal flap deflections were demonstrated. Finally, tests were performed in Glenn L. Martin wind tunnel using a model rotor rig to assess the performance of motor-flap system in forward flight. A swashplateless trim using brushless DC motor actuated trailing edge flaps was achieved for a rotor operating at 1200 RPM and an advance ratio of 0.28. Also, preliminary exploration was carried out to test the scalability of the motor

  2. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME ZERO: OVERVIEW AND COMMERCIAL PATH

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  3. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME TWO: INNOVATION & COST OF ENERGY

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  4. Kinematic control of aerodynamic forces on an inclined flapping wing with asymmetric strokes

    International Nuclear Information System (INIS)

    Park, Hyungmin; Choi, Haecheon

    2012-01-01

    In the present study, we conduct an experiment using a one-paired dynamically scaled model of an insect wing, to investigate how asymmetric strokes with different wing kinematic parameters are used to control the aerodynamics of a dragonfly-like inclined flapping wing in still fluid. The kinematic parameters considered are the angles of attack during the mid-downstroke (α md ) and mid-upstroke (α mu ), and the duration (Δτ) and time of initiation (τ p ) of the pitching rotation. The present dragonfly-like inclined flapping wing has the aerodynamic mechanism of unsteady force generation similar to those of other insect wings in a horizontal stroke plane, but the detailed effect of the wing kinematics on the force control is different due to the asymmetric use of the angle of attack during the up- and downstrokes. For example, high α md and low α mu produces larger vertical force with less aerodynamic power, and low α md and high α mu is recommended for horizontal force (thrust) production. The pitching rotation also affects the aerodynamics of a flapping wing, but its dynamic rotational effect is much weaker than the effect from the kinematic change in the angle of attack caused by the pitching rotation. Thus, the influences of the duration and timing of pitching rotation for the present inclined flapping wing are found to be very different from those for a horizontal flapping wing. That is, for the inclined flapping motion, the advanced and delayed rotations produce smaller vertical forces than the symmetric one and the effect of pitching duration is very small. On the other hand, for a specific range of pitching rotation timing, delayed rotation requires less aerodynamic power than the symmetric rotation. As for the horizontal force, delayed rotation with low α md and high α mu is recommended for long-duration flight owing to its high efficiency, and advanced rotation should be employed for hovering flight for nearly zero horizontal force. The present

  5. Comprehensive modeling and control of flexible flapping wing micro air vehicles

    Science.gov (United States)

    Nogar, Stephen Michael

    Flapping wing micro air vehicles hold significant promise due to the potential for improved aerodynamic efficiency, enhanced maneuverability and hover capability compared to fixed and rotary configurations. However, significant technical challenges exist to due the lightweight, highly integrated nature of the vehicle and coupling between the actuators, flexible wings and control system. Experimental and high fidelity analysis has demonstrated that aeroelastic effects can change the effective kinematics of the wing, reducing vehicle stability. However, many control studies for flapping wing vehicles do not consider these effects, and instead validate the control strategy with simple assumptions, including rigid wings, quasi-steady aerodynamics and no consideration of actuator dynamics. A control evaluation model that includes aeroelastic effects and actuator dynamics is developed. The structural model accounts for geometrically nonlinear behavior using an implicit condensation technique and the aerodynamic loads are found using a time accurate approach that includes quasi-steady, rotational, added mass and unsteady effects. Empirically based parameters in the model are fit using data obtained from a higher fidelity solver. The aeroelastic model and its ingredients are compared to experiments and computations using models of higher fidelity, and indicate reasonable agreement. The developed control evaluation model is implemented in a previously published, baseline controller that maintains stability using an asymmetric wingbeat, known as split-cycle, along with changing the flapping frequency and wing bias. The model-based controller determines the control inputs using a cycle-averaged, linear control design model, which assumes a rigid wing and no actuator dynamics. The introduction of unaccounted for dynamics significantly degrades the ability of the controller to track a reference trajectory, and in some cases destabilizes the vehicle. This demonstrates the

  6. Forward flight of swallowtail butterfly with simple flapping motion

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiroto [School of Engineering and Applied Sciences, Harvard University, 60 Oxford Street, Cambridge, MA 02138 (United States); Shimoyama, Isao, E-mail: isao@i.u-tokyo.ac.j [Department of Mechano-Informatics, Graduate School of Information Science and Technology, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 (Japan)

    2010-06-15

    Unlike other flying insects, the wing motion of swallowtail butterflies is basically limited to flapping because their fore wings partly overlap their hind wings, structurally restricting the feathering needed for active control of aerodynamic force. Hence, it can be hypothesized that the flight of swallowtail butterflies is realized with simple flapping, requiring little feedback control of the feathering angle. To verify this hypothesis, we fabricated an artificial butterfly mimicking the wing motion and wing shape of a swallowtail butterfly and analyzed its flights using images taken with a high-speed video camera. The results demonstrated that stable forward flight could be realized without active feathering or feedback control of the wing motion. During the flights, the artificial butterfly's body moved up and down passively in synchronization with the flapping, and the artificial butterfly followed an undulating flight trajectory like an actual swallowtail butterfly. Without feedback control of the wing motion, the body movement is directly affected by change of aerodynamic force due to the wing deformation; the degree of deformation was determined by the wing venation. Unlike a veinless wing, a mimic wing with veins generated a much higher lift coefficient during the flapping flight than in a steady flow due to the large body motion.

  7. Forward flight of swallowtail butterfly with simple flapping motion

    International Nuclear Information System (INIS)

    Tanaka, Hiroto; Shimoyama, Isao

    2010-01-01

    Unlike other flying insects, the wing motion of swallowtail butterflies is basically limited to flapping because their fore wings partly overlap their hind wings, structurally restricting the feathering needed for active control of aerodynamic force. Hence, it can be hypothesized that the flight of swallowtail butterflies is realized with simple flapping, requiring little feedback control of the feathering angle. To verify this hypothesis, we fabricated an artificial butterfly mimicking the wing motion and wing shape of a swallowtail butterfly and analyzed its flights using images taken with a high-speed video camera. The results demonstrated that stable forward flight could be realized without active feathering or feedback control of the wing motion. During the flights, the artificial butterfly's body moved up and down passively in synchronization with the flapping, and the artificial butterfly followed an undulating flight trajectory like an actual swallowtail butterfly. Without feedback control of the wing motion, the body movement is directly affected by change of aerodynamic force due to the wing deformation; the degree of deformation was determined by the wing venation. Unlike a veinless wing, a mimic wing with veins generated a much higher lift coefficient during the flapping flight than in a steady flow due to the large body motion.

  8. Wind tunnel tests with combined pitch and free-floating flap control: data-driven iterative feedforward controller tuning

    Directory of Open Access Journals (Sweden)

    S. T. Navalkar

    2016-10-01

    Full Text Available Wind turbine load alleviation has traditionally been addressed in the literature using either full-span pitch control, which has limited bandwidth, or trailing-edge flap control, which typically shows low control authority due to actuation constraints. This paper combines both methods and demonstrates the feasibility and advantages of such a combined control strategy on a scaled prototype in a series of wind tunnel tests. The pitchable blades of the test turbine are instrumented with free-floating flaps close to the tip, designed such that they aerodynamically magnify the low stroke of high-bandwidth actuators. The additional degree of freedom leads to aeroelastic coupling with the blade flexible modes. The inertia of the flaps was tuned such that instability occurs just beyond the operational envelope of the wind turbine; the system can however be stabilised using collocated closed-loop control. A feedforward controller is shown to be capable of significant reduction of the deterministic loads of the turbine. Iterative feedforward tuning, in combination with a stabilising feedback controller, is used to optimise the controller online in an automated manner, to maximise load reduction. Since the system is non-linear, the controller gains vary with wind speed; this paper also shows that iterative feedforward tuning is capable of generating the optimal gain schedule online.

  9. Phosphate steering by Flap Endonuclease 1 promotes 5′-flap specificity and incision to prevent genome instability

    KAUST Repository

    Tsutakawa, Susan E.

    2017-06-27

    DNA replication and repair enzyme Flap Endonuclease 1 (FEN1) is vital for genome integrity, and FEN1 mutations arise in multiple cancers. FEN1 precisely cleaves single-stranded (ss) 5\\'-flaps one nucleotide into duplex (ds) DNA. Yet, how FEN1 selects for but does not incise the ss 5\\'-flap was enigmatic. Here we combine crystallographic, biochemical and genetic analyses to show that two dsDNA binding sites set the 5\\'polarity and to reveal unexpected control of the DNA phosphodiester backbone by electrostatic interactions. Via phosphate steering\\', basic residues energetically steer an inverted ss 5\\'-flap through a gateway over FEN1\\'s active site and shift dsDNA for catalysis. Mutations of these residues cause an 18,000-fold reduction in catalytic rate in vitro and large-scale trinucleotide (GAA) repeat expansions in vivo, implying failed phosphate-steering promotes an unanticipated lagging-strand template-switch mechanism during replication. Thus, phosphate steering is an unappreciated FEN1 function that enforces 5\\'-flap specificity and catalysis, preventing genomic instability.

  10. Simulations of a rotor with active deformable trailing edge flaps in half-wake inflow: Comparison of EllipSys 3D with HAWC2

    DEFF Research Database (Denmark)

    Barlas, Thanasis K.; Zahle, Frederik; Sørensen, Niels N.

    2012-01-01

    Various research projects have focused on active aerodynamic load control of wind turbines using control devices on the blades, for example flaps. The aerodynamic load predictions of utilized aeroelastic codes have not yet been fully validated with full rotor CFD or experimental results. In this ...... a controller based on a Pitot tube velocity feedback measured at flap mid-span. Good agreement is found between EllipSys3D and HAWC2 in the prediction of the dynamic blade loads, considering the high complexity of the flow case....

  11. A Model Based Control methodology combining Blade Pitch and Adaptive Trailing Edge Flaps in a common framework

    DEFF Research Database (Denmark)

    Henriksen, Lars Christian; Bergami, Leonardo; Andersen, Peter Bjørn

    2013-01-01

    This work investigates how adaptive trailing edge flaps and classical blade pitch can work in concert using a model-based state space control formulation. The trade-off between load reduction and actuator activity is decided by setting different weights in the objective function used by the model...

  12. A Model Based Control methodology combining Blade Pitch and Adaptive Trailing Edge Flaps in a common framework

    DEFF Research Database (Denmark)

    This work investigates how adaptive trailing edge flaps and classical blade pitch can work in concert using a model-based state space control formulation. The trade-off between load reduction and actuator activity is decided by setting different weights in the objective function used by the model...

  13. Laser resurfacing of skin flaps: an experimental comparison

    Directory of Open Access Journals (Sweden)

    Srdan Babovic

    2011-05-01

    Full Text Available Objective. The influence of Coherent Ultrapulse, TruPulse and Erbium: YAG laser skin resurfacing on survival of the skin flaps when performed simultaneously was evaluated. Material and methods. We used twelve female Yucatan minipigs in the study. Skin flaps including paniculus carnosus were raised on the animals’ back. The flaps were sutured into the defect under tension. We designed 4 experimental groups: Control-Flaps only, Group 2-Flaps + 4 immediate TruPulse laser passes, Group 3-Flaps + 2 immediate Coherent UltraPulse laser passes, Group 4-Flaps – immediate 50J/cm2 total fluence with Erbium: YAG laser. Results. Flap survival in Control group was 98.8%. There was no flap in Group 2 with complete survival. Survival of the flaps in Group 2 (Tru-Pulse ranged from 75-90%, with average flap survival area of 85.2%. In Group 3 (UltraPulse all 24 flaps had some area of necrosis. Flap survival in Group 3 ranged from 75-95%, with an average of 85.6%. In Group 4 (Erbium: YAG flap survival area ranged from 70-95%, with all 24 flaps with some area of necrosis, with average flap survival area of 87.3%. There is a significant statistical difference in flap survival area between groups 2, 3 and 4 versus Control (p<0.001. Conclusion. The results of our study suggest that laser resurfacing of skin flaps sutured under tension in the same operative session is detrimental for skin flap survival. We also found no significant difference in flap survival area between TruPulse, Coherent UltraPulse and Erbium: YAG laser treated flaps.

  14. Reduced In-Plane, Low Frequency Helicopter Noise of an Active Flap Rotor

    Science.gov (United States)

    Sim, Ben W.; Janakiram, Ram D.; Barbely, Natasha L.; Solis, Eduardo

    2009-01-01

    Results from a recent joint DARPA/Boeing/NASA/Army wind tunnel test demonstrated the ability to reduce in-plane, low frequency noise of the full-scale Boeing-SMART rotor using active flaps. Test data reported in this paper illustrated that acoustic energy in the first six blade-passing harmonics could be reduced by up to 6 decibels at a moderate airspeed, level flight condition corresponding to advance ratio of 0.30. Reduced noise levels were attributed to selective active flap schedules that modified in-plane blade airloads on the advancing side of the rotor, in a manner, which generated counteracting acoustic pulses that partially offset the negative pressure peaks associated with in-plane, steady thickness noise. These favorable reduced-noise operating states are a strong function of the active flap actuation amplitude, frequency and phase. The associated noise reductions resulted in reduced aural detection distance by up to 18%, but incurred significant vibratory load penalties due to increased hub shear forces. Small reductions in rotor lift-to-drag ratios, of no more than 3%, were also measured

  15. Edaravone enhances the viability of ischemia/reperfusion flaps.

    Science.gov (United States)

    Zhang, Dong-Yi; Kang, Shen-Song; Zhang, Zheng-Wen; Wu, Rui

    2017-02-01

    The purpose of the experiment was to study the efficacy of edaravone in enhancing flap viability after ischemia/reperfusion (IR) and its mechanism. Forty-eight adult male SD rats were randomly divided into 3 groups: control group (n=16), IR group (n=16), and edaravone-treated IR group (n=16). An island flap at left lower abdomen (6.0 cm×3.0 cm in size), fed by the superficial epigastric artery and vein, was created in each rat of all the three groups. The arterial blood flow of flaps in IR group and edaravone-treated IR group was blocked for 10 h, and then the blood perfusion was restored. From 15 min before reperfusion, rats in the edaravone-treated IR group were intraperitoneally injected with edaravone (10 mg/kg), once every 12 h, for 3 days. Rats in the IR group and control group were intraperitoneally injected with saline, with the same method and frequency as the rats in the edaravone-treated IR group. In IR group and edaravone-treated IR group, samples of flaps were harvested after reperfusion of the flaps for 24 h. In the control group, samples of flaps were harvested 34 h after creation of the flaps. The content of malondialdehyde (MDA) and activity of superoxide dismutase (SOD) were determined, and changes in organizational structure and infiltration of inflammatory cells were observed by hematoxylin-eosin (HE) staining, apoptotic cells of vascular wall were marked by terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) assay, and the apoptotic rate of cells in vascular wall was calculated. The ultrastructural changes of vascular endothelial cells were observed by transmission electron microscopy (TEM). Seven days after the operation, we calculated the flap viability of each group, and marked vessels of flaps by immunohistochemical staining for calculating the average number of subcutaneous vessels. The results showed that the content of MDA, the number of multicore inflammatory cells and apoptotic rate of cells in vascular wall

  16. Investigation of the load reduction potential of two trailing edge flap controls using CFD

    DEFF Research Database (Denmark)

    Heinz, Joachim Christian; Sørensen, Niels N.; Zahle, Frederik

    2011-01-01

    ) and subjected to a turbulent inflow signal. The employed airfoil model corresponds to a successfully tested prototype airfoil where piezoelectric actuators were used for the flapping. In the present investigation two possible control methods for the flap are compared in their ability to reduce the fluctuating......In this work, a 2D aero‐servo‐elastic model of an airfoil section with 3 degrees of freedom (DOF) based on the 2D CFD solver EllipSys2D to calculate the aerodynamic forces is utilized to calculate the load reduction potential of an airfoil equipped with an adaptive trailing edge flap (ATEF...... normal forces on the airfoil due to a 4 s turbulent inflow signal and the best location of the measurement point for the respective control input is determined. While Control 1 uses the measurements of a Pitot tube mounted in front of the leading edge (LE) as input, Control 2 uses the pressure difference...

  17. Closed loop control of a flap exposed to harmonic aerodynamic actuation

    DEFF Research Database (Denmark)

    Velte, Clara Marika; Mikkelsen, Robert Flemming; Sørensen, Jens Nørkær

    2012-01-01

    Wind tunnel testing of a two-dimensional aerofoil with a load reducing flap has been conducted under the influence of a closed-loop controller (PID). Upstream synthetic perturbations for well-defined testing of the controller were generated by instrumenting the wind tunnel with two fast turning...

  18. Numerical Investigation of Flow Control Feasibility with a Trailing Edge Flap

    International Nuclear Information System (INIS)

    Zhu, W J; Shen, W Z; Sørensen, J N

    2014-01-01

    This paper concerns a numerical study of employing an adaptive trailing edge flap to control the lift of an airfoil subject to unsteady inflow conditions. The periodically varying inflow is generated by two oscillating airfoils, which are located upstream of the controlled airfoil. To establish the control system, a standard PID controller is implemented in a finite volume based incompressible flow solver. An immersed boundary method is applied to treat the problem of simulating a deformable airfoil trailing edge. The flow field is solved using a 2D Reynolds averaged Navier-Stokes finite volume solver. In order to more accurately simulate wall bounded flows around the immersed boundary, a modified boundary condition is introduced in the k- ω turbulence model. As an example, turbulent flow over a NACA 64418 airfoil with a deformable trailing edge is investigated. Results from numerical simulations are convincing and may give some highlights for practical implementations of trailing edge flap to a wind turbine rotor blade

  19. Load alleviation potential of the Controllable Rubber Trailing Edge Flap (CRTEF) in the INDUFLAP project

    DEFF Research Database (Denmark)

    Barlas, Thanasis K.; Bergami, Leonardo; Hansen, Morten Hartvig

    The load alleviation potential of the Controllable Rubber Trailing Edge Flap (CRTEF) is verified on a full Design Load Base (DLB) setup using the aeroelastic code HAWC2, and by investigating a flap configuration for the NREL 5MW Reference Wind Turbine (RWT) model. The performance of the CRTEF...

  20. Flap controllers applied on the OffshoreWindChina (OWC) 5MW reference wind turbine for Chinese typhoon conditions

    DEFF Research Database (Denmark)

    Barlas, Athanasios

    The report describes the development of flap controllers applied on the OffshoreWindChina (OWC) 5MW reference wind turbine for Chinese typhoon conditions. Optimal flap controllers are designed and tuned based on linear aeroelastic models from HawcStab2. The controllers are evaluated in normal......, parked and storm conditions, targeting the alleviation of fatigue and extreme loads....

  1. Aerodynamics power consumption for mechanical flapping wings undergoing flapping and pitching motion

    Science.gov (United States)

    Razak, N. A.; Dimitriadis, G.; Razaami, A. F.

    2017-07-01

    Lately, due to the growing interest in Micro Aerial Vehicles (MAV), interest in flapping flight has been rekindled. The reason lies in the improved performance of flapping wing flight at low Reynolds number regime. Many studies involving flapping wing flight focused on the generation of unsteady aerodynamic forces such as lift and thrust. There is one aspect of flapping wing flight that received less attention. The aspect is aerodynamic power consumption. Since most mechanical flapping wing aircraft ever designed are battery powered, power consumption is fundamental in improving flight endurance. This paper reports the results of experiments carried out on mechanical wings under going active root flapping and pitching in the wind tunnel. The objective of the work is to investigate the effect of the pitch angle oscillations and wing profile on the power consumption of flapping wings via generation of unsteady aerodynamic forces. The experiments were repeated for different airspeeds, flapping and pitching kinematics, geometric angle of attack and wing sections with symmetric and cambered airfoils. A specially designed mechanical flapper modelled on large migrating birds was used. It will be shown that, under pitch leading conditions, less power is required to overcome the unsteady aerodnamics forces. The study finds less power requirement for downstroke compared to upstroke motion. Overall results demonstrate power consumption depends directly on the unsteady lift force.

  2. [Saphenous perforator flap].

    Science.gov (United States)

    Winkel, R; Tajsic, N; Husum, H; Schlageter, M; Hanebuth, G; Hoffmann, R

    2013-04-01

    by "artificial skin". A gap in the bandage over the skin island allows for observation. Protocol of controls of vascularization: color and time for revascularization; antibiotic treatment according to bacteriological testing. In case of edema or discoloration of the flap: immediate removal of sutures, administration of leeches, operative revision. Split skin graft 1 week after flap transposition, if the skin had been temporary substituted. Retrospective uncontrolled study with over 70 saphenous perforator flaps from 1995-2011. Full soft tissue defects 62 times with osteomyelitis, 3 times with endoprothesis, 3 times with fractures, 2 times with exposed tendons. From 1995-2006, 44/50 (88 %) flaps healed completely or at least to 3/4 without the necessity of further flaps; from 2007-2011, 13/20 (65 %) flaps healed completely and 6/20 (30 %) flaps healed at least to 3/4 without the necessity of further flaps, loss of one flap (5 %).

  3. Aerodynamics, sensing and control of insect-scale flapping-wing flight

    Science.gov (United States)

    Shyy, Wei; Kang, Chang-kwon; Chirarattananon, Pakpong; Ravi, Sridhar; Liu, Hao

    2016-01-01

    There are nearly a million known species of flying insects and 13 000 species of flying warm-blooded vertebrates, including mammals, birds and bats. While in flight, their wings not only move forward relative to the air, they also flap up and down, plunge and sweep, so that both lift and thrust can be generated and balanced, accommodate uncertain surrounding environment, with superior flight stability and dynamics with highly varied speeds and missions. As the size of a flyer is reduced, the wing-to-body mass ratio tends to decrease as well. Furthermore, these flyers use integrated system consisting of wings to generate aerodynamic forces, muscles to move the wings, and sensing and control systems to guide and manoeuvre. In this article, recent advances in insect-scale flapping-wing aerodynamics, flexible wing structures, unsteady flight environment, sensing, stability and control are reviewed with perspective offered. In particular, the special features of the low Reynolds number flyers associated with small sizes, thin and light structures, slow flight with comparable wind gust speeds, bioinspired fabrication of wing structures, neuron-based sensing and adaptive control are highlighted. PMID:27118897

  4. Experimental validation of a true-scale morphing flap for large civil aircraft applications

    Science.gov (United States)

    Pecora, R.; Amoroso, F.; Arena, M.; Noviello, M. C.; Rea, F.

    2017-04-01

    Within the framework of the JTI-Clean Sky (CS) project, and during the first phase of the Low Noise Configuration Domain of the Green Regional Aircraft - Integrated Technological Demonstration (GRA-ITD, the preliminary design and technological demonstration of a novel wing flap architecture were addressed. Research activities were carried out to substantiate the feasibility of morphing concepts enabling flap camber variation in compliance with the demanding safety requirements applicable to the next generation green regional aircraft, 130- seats with open rotor configuration. The driving motivation for the investigation on such a technology was found in the opportunity to replace a conventional double slotted flap with a single slotted camber-morphing flap assuring similar high lift performances -in terms of maximum attainable lift coefficient and stall angle- while lowering emitted noise and system complexity. Studies and tests were limited to a portion of the flap element obtained by slicing the actual flap geometry with two cutting planes distant 0.8 meters along the wing span. Further activities were then addressed in order to increase the TRL of the validated architecture within the second phase of the CS-GRA. Relying upon the already assessed concept, an innovative and more advanced flap device was designed in order to enable two different morphing modes on the basis of the A/C flight condition / flap setting: Mode1, Overall camber morphing to enhance high-lift performances during take-off and landing (flap deployed); Mode2, Tab-like morphing mode. Upwards and downwards deflection of the flap tip during cruise (flap stowed) for load control at high speed. A true-scale segment of the outer wing flap (4 meters span with a mean chord of 0.9 meters) was selected as investigation domain for the new architecture in order to duly face the challenges posed by real wing installation. Advanced and innovative solutions for the adaptive structure, actuation and control

  5. Synthetic, structural mimetics of the β-hairpin flap of HIV-1 protease inhibit enzyme function.

    Science.gov (United States)

    Chauhan, Jay; Chen, Shen-En; Fenstermacher, Katherine J; Naser-Tavakolian, Aurash; Reingewertz, Tali; Salmo, Rosene; Lee, Christian; Williams, Emori; Raje, Mithun; Sundberg, Eric; DeStefano, Jeffrey J; Freire, Ernesto; Fletcher, Steven

    2015-11-01

    Small-molecule mimetics of the β-hairpin flap of HIV-1 protease (HIV-1 PR) were designed based on a 1,4-benzodiazepine scaffold as a strategy to interfere with the flap-flap protein-protein interaction, which functions as a gated mechanism to control access to the active site. Michaelis-Menten kinetics suggested our small-molecules are competitive inhibitors, which indicates the mode of inhibition is through binding the active site or sterically blocking access to the active site and preventing flap closure, as designed. More generally, a new bioactive scaffold for HIV-1PR inhibition has been discovered, with the most potent compound inhibiting the protease with a modest K(i) of 11 μM. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Aeroelastic Optimization of a 10 MW Wind Turbine Blade with Active Trailing Edge Flaps

    DEFF Research Database (Denmark)

    Barlas, Athanasios; Tibaldi, Carlo; Zahle, Frederik

    2016-01-01

    This article presents the aeroelastic optimization of a 10MW wind turbine ‘smart blade’ equipped with active trailing edge flaps. The multi-disciplinary wind turbine analysis and optimization tool HawtOpt2 is utilized, which is based on the open-source framework Open-MDAO. The tool interfaces...... to several state-of-the art simulation codes, allowing for a wide variety of problem formulations and combinations of models. A simultaneous aerodynamic and structural optimization of a 10 MW wind turbine rotor is carried out with respect to material layups and outer shape. Active trailing edge flaps...

  7. Pitching motion control of a butterfly-like 3D flapping wing-body model

    Science.gov (United States)

    Suzuki, Kosuke; Minami, Keisuke; Inamuro, Takaji

    2014-11-01

    Free flights and a pitching motion control of a butterfly-like flapping wing-body model are numerically investigated by using an immersed boundary-lattice Boltzmann method. The model flaps downward for generating the lift force and backward for generating the thrust force. Although the model can go upward against the gravity by the generated lift force, the model generates the nose-up torque, consequently gets off-balance. In this study, we discuss a way to control the pitching motion by flexing the body of the wing-body model like an actual butterfly. The body of the model is composed of two straight rigid rod connected by a rotary actuator. It is found that the pitching angle is suppressed in the range of +/-5° by using the proportional-plus-integral-plus-derivative (PID) control for the input torque of the rotary actuator.

  8. Free-style puzzle flap: the concept of recycling a perforator flap.

    Science.gov (United States)

    Feng, Kuan-Ming; Hsieh, Ching-Hua; Jeng, Seng-Feng

    2013-02-01

    Theoretically, a flap can be supplied by any perforator based on the angiosome theory. In this study, the technique of free-style perforator flap dissection was used to harvest a pedicled or free skin flap from a previous free flap for a second difficult reconstruction. The authors call this a free-style puzzle flap. For the past 3 years, the authors treated 13 patients in whom 12 pedicled free-style puzzle flaps were harvested from previous redundant free flaps and recycled to reconstruct soft-tissue defects at various anatomical locations. One free-style free puzzle flap was harvested from a previous anterolateral thigh flap for buccal cancer to reconstruct a foot defect. Total flap survival was attained in 12 of 13 flaps. One transferred flap failed completely. This patient had received postoperative radiotherapy after the initial cancer ablation and free anterolateral thigh flap reconstruction. Another free flap was used to close and reconstruct the wound. All the donor sites could be closed primarily. The free-style puzzle flap, harvested from a previous redundant free flap and used as a perforator flap to reconstruct a new defect, has proven to be versatile and reliable. When indicated, it is an alternative donor site for further reconstruction of soft-tissue defects.

  9. Draught regulator with control flap lowers dew point, keeps stacks dry

    Energy Technology Data Exchange (ETDEWEB)

    Dreizler, U.; Dreizler, W.

    1982-11-30

    Draught regulators for auxiliary air are particularly important in older stacks operated with new boilers and burners. Owing to better ventilation during burner operation and standstill, the dew point of flue gases will be lowered so that water vapour condensation will be prevented. Postfitting of draught regulators will also help in stacks already damaged by condensation water. The draught regulator has a control flap for better control of auxiliary air supply.

  10. Adaptive Trailing Edge Flaps for Active Load Alleviation in a Smart Rotor Configuration

    DEFF Research Database (Denmark)

    Bergami, Leonardo

    to withstand. The investigation focuses on a specific actuator type: the Adaptive Trailing Edge Flap (ATEF), which introduces a continuous deformation of the aft part of the airfoil camber-line. An aerodynamic model that accounts for the steady and unsteady effects of the flap deflection on a 2D airfoil...... section is developed, and, considering both attached and separated flow conditions, is validated by comparison against Computational Fluid Dynamic solutions and a panel code method. The aerodynamic model is integrated in the BEM-based aeroelastic simulation code HAWC2, thus providing a tool able...... with flaps laid out on the outer 20 % of the blade span, from 77 % to 97% of the blade length. The configuration is first tested with a simplified cyclic control approach, which gives a preliminary indication of the load alleviation potential, and also reveals the possibility to enhance the rotor energy...

  11. A standardized model for predicting flap failure using indocyanine green dye

    Science.gov (United States)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  12. The effect of atorvastatin on survival of rat ischemic flap

    Directory of Open Access Journals (Sweden)

    Jian-Xun Chen

    2013-04-01

    Full Text Available Management of skin avulsion with tissue exposure is a challenge for plastic surgeons. Clinical observations have suggested that longer survival of skin flap prevents further contamination and infection. Less well known is the role of atorvastatin in avulsion skin flap. Therefore, we attempted to determine whether atorvastatin could alleviate avulsion skin flap in a rat model. Twenty male Sprague–Dawley rats were randomized into two groups: the atorvastatin group and the control. Before operation, each rat received an initial blood perfusion scan as baseline data. Then, each rat received an operation of skin flap incision, elevation, and resuturing to the original position under general anesthesia. Another blood perfusion scan was performed on each rat 30 minutes, 4 days, and 7 days postoperatively. On the 7th postoperative day, the necrotic area of skin flap was measured as the skin flap viability. The skin flap tissues at 2.5 and 5 cm distal to the skin flap base were collected for histopathological analysis, as well as measurement of vascular endothelial growth factor (VEGF mRNA expression, and vascular density. Compared with 30 minutes postoperation, there was a significant increase in the ratio of skin flap blood perfusion on the 4th and 7th days postoperation in both control and atorvastatin groups (p<0.05. Compared with the control group, there was a significant decrease in necrotic area, significant increase in ratio of skin flap blood perfusion on postoperation days 4 and 7, and significant increase in vascular density under high field at 2.5 cm distal to the base of skin flap in the atorvastatin group (p<0.05. The VEGF121 and VEGF165 mRNA expression at 2.5 cm distal to the base of skin flap differed significantly between the two groups (p<0.05. Compared with the control group, atorvastatin treatment improved skin flap blood perfusion, vascular density, and necrotic area dependent on VEGF mRNA expression.

  13. Effects of hyperbaric oxygen and irradiation on experimental skin flaps in rats

    International Nuclear Information System (INIS)

    Nemiroff, P.M.; Merwin, G.E.; Brant, T.; Cassisi, N.J.

    1985-01-01

    This study investigated the effects of hyperbaric oxygen (HBO) and irradiation (RT) on experimental skin flaps in rats under varying conditions. Animals were assigned at random to 1 of 15 groups that represented all possible ordering effects of HBO, RT, and flap, as well as controls that included flap-only, RT-only, and HBO-only groups. Cranially based skin flaps measuring 3 x 9 cm were elevated on the dorsum. The surviving length was evaluated with fluorescein dye 7 days after the operation. Depending on the treatment condition, HBO was given either 48 hours or 24 hours before flap elevation, or within 4 hours or 48 hours after flap elevation. Rats receiving RT ( 60 Co) were given a single dose of 1000 rads to the dorsum. Results showed that all groups receiving HBO within 4 hours after flap elevation had significantly greater flap survival length, with as much as a 22% greater length of surviving flap. HBO given 48 hours before flap elevation also significantly improved flap survival over controls. RT appeared to have no immediate significant effect on flap survival. However, rats receiving RT, regardless of other factors, gained significantly less weight than did controls. Findings clearly indicate that, to be effective, HBO needs to be given as soon after surgery as possible

  14. Rate-determining Step of Flap Endonuclease 1 (FEN1) Reflects a Kinetic Bias against Long Flaps and Trinucleotide Repeat Sequences.

    Science.gov (United States)

    Tarantino, Mary E; Bilotti, Katharina; Huang, Ji; Delaney, Sarah

    2015-08-21

    Flap endonuclease 1 (FEN1) is a structure-specific nuclease responsible for removing 5'-flaps formed during Okazaki fragment maturation and long patch base excision repair. In this work, we use rapid quench flow techniques to examine the rates of 5'-flap removal on DNA substrates of varying length and sequence. Of particular interest are flaps containing trinucleotide repeats (TNR), which have been proposed to affect FEN1 activity and cause genetic instability. We report that FEN1 processes substrates containing flaps of 30 nucleotides or fewer at comparable single-turnover rates. However, for flaps longer than 30 nucleotides, FEN1 kinetically discriminates substrates based on flap length and flap sequence. In particular, FEN1 removes flaps containing TNR sequences at a rate slower than mixed sequence flaps of the same length. Furthermore, multiple-turnover kinetic analysis reveals that the rate-determining step of FEN1 switches as a function of flap length from product release to chemistry (or a step prior to chemistry). These results provide a kinetic perspective on the role of FEN1 in DNA replication and repair and contribute to our understanding of FEN1 in mediating genetic instability of TNR sequences. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  15. DNA and Protein Requirements for Substrate Conformational Changes Necessary for Human Flap Endonuclease-1-catalyzed Reaction*

    Science.gov (United States)

    Algasaier, Sana I.; Exell, Jack C.; Bennet, Ian A.; Thompson, Mark J.; Gotham, Victoria J. B.; Shaw, Steven J.; Craggs, Timothy D.; Finger, L. David; Grasby, Jane A.

    2016-01-01

    Human flap endonuclease-1 (hFEN1) catalyzes the essential removal of single-stranded flaps arising at DNA junctions during replication and repair processes. hFEN1 biological function must be precisely controlled, and consequently, the protein relies on a combination of protein and substrate conformational changes as a prerequisite for reaction. These include substrate bending at the duplex-duplex junction and transfer of unpaired reacting duplex end into the active site. When present, 5′-flaps are thought to thread under the helical cap, limiting reaction to flaps with free 5′-termini in vivo. Here we monitored DNA bending by FRET and DNA unpairing using 2-aminopurine exciton pair CD to determine the DNA and protein requirements for these substrate conformational changes. Binding of DNA to hFEN1 in a bent conformation occurred independently of 5′-flap accommodation and did not require active site metal ions or the presence of conserved active site residues. More stringent requirements exist for transfer of the substrate to the active site. Placement of the scissile phosphate diester in the active site required the presence of divalent metal ions, a free 5′-flap (if present), a Watson-Crick base pair at the terminus of the reacting duplex, and the intact secondary structure of the enzyme helical cap. Optimal positioning of the scissile phosphate additionally required active site conserved residues Tyr40, Asp181, and Arg100 and a reacting duplex 5′-phosphate. These studies suggest a FEN1 reaction mechanism where junctions are bound and 5′-flaps are threaded (when present), and finally the substrate is transferred onto active site metals initiating cleavage. PMID:26884332

  16. A PIV Study of Baseline and Controlled Flow over the Highly Deflected Flap of a Generic Low Aspect Ratio Trapezoidal Wing

    Science.gov (United States)

    Tewes, Philipp; Genschow, Konstantin; Little, Jesse; Wygnanski, Israel

    2017-11-01

    A detailed flow survey using PIV was conducted over a highly-deflected flap (55°) of a low-aspect ratio trapezoidal wing. The wing section is a NACA 0012 with 45° sweep at both the leading and trailing edges, an aspect ratio of 1.5 and a taper ratio of 0.27. The main element is equipped with 7 equally spaced fluidic oscillators, covering the inner 60 % of the span, located near the flap hinge. Experiments were carried out at 0° and 8° incidence at a Reynolds number of 1.7 .106 for both baseline and active flow control (AFC) cases. Velocity ISO-surfaces, x-vorticity and streamlines are analyzed / discussed. A flap leading edge vortex governs the baseline flow field for 0°. This vortical structure interacts with the jets emitted by the actuators (Cμ = 1 %). Its development is hampered and the vortex is redirected toward the trailing edge resulting in a CL increase. At 8°, the dominant flap leading edge vortex could not be detected and is believed to have already merged with the tip vortex. AFC attached the flow over the flap and enhanced the lift by up to 20 % while maintaining longitudinal stability. The dominant flow features in the AFC cases are actuator-generated streamwise vortices which appear stronger at 8°. This work was supported by the Office of Naval Research under ONR Grant No. N00014-14-1-0387.

  17. Flap Edge Noise Reduction Fins

    Science.gov (United States)

    Khorrami, Mehdi R. (Inventor); Choudhan, Meelan M. (Inventor)

    2015-01-01

    A flap of the type that is movably connected to an aircraft wing to provide control of an aircraft in flight includes opposite ends, wherein at least a first opposite end includes a plurality of substantially rigid, laterally extending protrusions that are spaced apart to form a plurality of fluidly interconnected passageways. The passageways have openings adjacent to upper and lower sides of the flap, and the passageways include a plurality of bends such that high pressure fluid flows from a high pressure region to a low pressure region to provide a boundary condition that inhibits noise resulting from airflow around the end of the flap.

  18. Low-Speed Wind-Tunnel Investigation of Blowing Boundary-Layer Control on Leading- and Trailing-Edge Flaps of a Large-Scale, Low-Aspect-Ratio, 45 Swept-wing Airplane Configuration

    Science.gov (United States)

    Maki, Ralph L.

    1959-01-01

    Blowing boundary-layer control was applied to the leading- and trailing-edge flaps of a 45 deg sweptback-wing complete model in a full-scale low-speed wind-tunnel study. The principal purpose of the study was to determine the effects of leading-edge flap deflection and boundary-layer control on maximum lift and longitudinal stability. Leading-edge flap deflection alone was sufficient to maintain static longitudinal stability without trailing-edge flaps. However, leading-edge flap blowing was required to maintain longitudinal stability by delaying leading-edge flow separation when trailing-edge flaps were deflected either with or without blowing. Partial-span leading-edge flaps deflected 60 deg with moderate blowing gave the major increase in maximum lift, although higher deflection and additional blowing gave some further increase. Inboard of 0.4 semispan leading-edge flap deflection could be reduced to 40 deg and/or blowing could be omitted with only small loss in maximum lift. Trailing-edge flap lift increments were increased by boundary-layer control for deflections greater than 45 deg. Maximum lift was not increased with deflected trailing-edge flaps with blowing.

  19. Keystone flaps in coloured skin: Flap technology for the masses?

    Directory of Open Access Journals (Sweden)

    Satish P Bhat

    2013-01-01

    Full Text Available Introduction: Viscoelastic properties of skin in coloured ethnic groups are less favourable compared to Caucasians for executing Keystone flaps. Keystone flaps have so far been evaluated and reported only in Caucasians. The potential of Keystone flaps in a coloured ethnic group is yet unknown. Aim: This article reviews the experience to reconstruct skin defects presenting in a coloured ethnic group, by using Keystone flaps, with a review of existing literature. Design: Uncontrolled case series. Materials and Methods: This retrospective review involves 55 consecutive Keystone flaps used from 2009 to 2012, for skin defects in various locations. Patient demographic data, medical history, co-morbidity, surgical indication, defect features, complications, and clinical outcomes are evaluated and presented. Results: In this population group with Fitzpatrick type 4 and 5 skin, the average patient age was 35.73. Though 60% of flaps (33/55 in the series involved specific risk factors, only two flaps failed. Though seven flaps had complications, sound healing was achieved by suitable intervention giving a success rate of 96.36%. Skin grafts were needed in only four cases. Conclusions: Keystone flaps achieve primary wound healing for a wide spectrum of defects with an acceptable success rate in a coloured skin population with unfavorable biophysical properties. By avoiding conventional local flaps and at times even microsurgical flaps, good aesthetic outcome is achieved without additional skin grafts or extensive operative time. All advantages seen in previous studies were verified. These benefits can be most appreciated in coloured populations, with limited resources and higher proportion of younger patients and unfavorable defects.

  20. Influence of hinge point on flexible flap aerodynamic performance

    International Nuclear Information System (INIS)

    Zhao, H Y; Ye, Z; Wu, P; Li, C

    2013-01-01

    Large scale wind turbines lead to increasing blade lengths and weights, which presents new challenges for blade design. This paper selects NREL S809 airfoil, uses the parameterized technology to realize the flexible trailing edge deformation, researches the static aerodynamic characteristics of wind turbine blade airfoil with flexible deformation, and the dynamic aerodynamic characteristics in the process of continuous deformation, analyses the influence of hinge point position on flexible flap aerodynamic performance, in order to further realize the flexible wind turbine blade design and provides some references for the active control scheme. The results show that compared with the original airfoil, proper trailing edge deformation can improve the lift coefficient, reduce the drag coefficient, and thereby more efficiently realize flow field active control. With hinge point moving forward, total aerodynamic performance of flexible flap improves. Positive swing angle can push the transition point backward, thus postpones the occurrence of the transition phenomenon

  1. Influence of inflow angle on flexible flap aerodynamic performance

    International Nuclear Information System (INIS)

    Zhao, H Y; Ye, Z; Li, Z M; Li, C

    2013-01-01

    Large scale wind turbines have larger blade lengths and weights, which creates new challenges for blade design. This paper selects NREL S809 airfoil, and uses the parameterized technology to realize the flexible trailing edge deformation, researches the dynamic aerodynamic characteristics in the process of continuous flexible deformation, analyses the influence of inflow angle on flexible flap aerodynamic performance, in order to further realize the flexible wind turbine blade design and provides some references for the active control scheme. The results show that compared with the original airfoil, proper trailing edge deformation can improve the lift coefficient, reduce the drag coefficient, and thereby more efficiently realize flow field active control. With inflow angle increases, dynamic lift-drag coefficient hysteresis loop shape deviation occurs, even turns into different shapes. Appropriate swing angle can improve the flap lift coefficient, but may cause early separation of flow. To improve the overall performance of wind turbine blades, different angular control should be used at different cross sections, in order to achieve the best performance

  2. Pedicled perforator flaps

    DEFF Research Database (Denmark)

    Demirtas, Yener; Ozturk, Nuray; Kelahmetoglu, Osman

    2009-01-01

    Described in this study is a surgical concept that supports the "consider and use a pedicled perforator flap whenever possible and indicated" approach to reconstruct a particular skin defect. The operation is entirely free-style; the only principle is to obtain a pedicled perforator flap...... to reconstruct the defect. The perforators are marked with a hand-held Doppler probe and multiple flaps are designed. The appropriate flap is elevated after identifying the perforator(s). Dissection of the perforator(s) or complete incision of the flap margins are not mandatory if the flap is mobilized...... adequately to cover the defect. Defects measuring 3 x 3 cm up to 20 x 20 cm at diverse locations were successfully reconstructed in 20 of 21 patients with 26 flaps. Pedicled perforator flaps offer us reliable and satisfactory results of reconstruction at different anatomic territories of the body. It sounds...

  3. Flow control over a NACA 0012 airfoil using dielectric-barrier-discharge plasma actuator with a Gurney flap

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Li-Hao [Beijing University of Aeronautics and Astronautics, Fluid Mechanics Key Laboratory of Education Ministry, Beijing (China); University of Nottingham, University Park, Faculty of Engineering, Nottingham (United Kingdom); Jukes, Timothy N. [University of Nottingham, University Park, Faculty of Engineering, Nottingham (United Kingdom); AIST, Research Centre for New Fuels and Vehicle Technology, Tsukuba (Japan); Choi, Kwing-So [University of Nottingham, University Park, Faculty of Engineering, Nottingham (United Kingdom); Wang, Jin-Jun [Beijing University of Aeronautics and Astronautics, Fluid Mechanics Key Laboratory of Education Ministry, Beijing (China)

    2012-06-15

    Flow control study of a NACA 0012 airfoil with a Gurney flap was carried out in a wind tunnel, where it was demonstrated that a dielectric-barrier-discharge (DBD) plasma actuator attached to the flap could increase the lift further, but with a small drag penalty. Time-resolved PIV measurements of the near-wake region indicated that the plasma forcing shifted the wake downwards, reducing its recirculation length. Analysis of wake vortex dynamics suggested that the plasma actuator initially amplified the lower wake shear layer by adding momentum along the downstream surface of the Gurney flap. This enhanced mutual entrainment between the upper and lower wake vortices, leading to an increase in lift on the airfoil. (orig.)

  4. Dynamics of an Active-Site Flap Contributes to Catalysis in a JAMM Family Metallo Deubiquitinase.

    Science.gov (United States)

    Bueno, Amy N; Shrestha, Rashmi K; Ronau, Judith A; Babar, Aditya; Sheedlo, Michael J; Fuchs, Julian E; Paul, Lake N; Das, Chittaranjan

    2015-10-06

    The endosome-associated deubiquitinase (DUB) AMSH is a member of the JAMM family of zinc-dependent metallo isopeptidases with high selectivity for Lys63-linked polyubiquitin chains, which play a key role in endosomal-lysosomal sorting of activated cell surface receptors. The catalytic domain of the enzyme features a flexible flap near the active site that opens and closes during its catalytic cycle. Structural analysis of its homologues, AMSH-LP (AMSH-like protein) and the fission yeast counterpart, Sst2, suggests that a conserved Phe residue in the flap may be critical for substrate binding and/or catalysis. To gain insight into the contribution of this flap in substrate recognition and catalysis, we generated mutants of Sst2 and characterized them using a combination of enzyme kinetics, X-ray crystallography, molecular dynamics simulations, and isothermal titration calorimetry (ITC). Our analysis shows that the Phe residue in the flap contributes key interactions during the rate-limiting step but not to substrate binding, since mutants of Phe403 exhibit a defect only in kcat but not in KM. Moreover, ITC studies show Phe403 mutants have similar KD for ubiquitin compared to the wild-type enzyme. The X-ray structures of both Phe403Ala and the Phe403Trp, in both the free and ubiquitin bound form, reveal no appreciable structural change that might impair substrate or alter product binding. We observed that the side chain of the Trp residue is oriented identically with respect to the isopeptide moiety of the substrate as the Phe residue in the wild-type enzyme, so the loss of activity seen in this mutant cannot be explained by the absence of a group with the ability to provide van der Waals interactions that facilitate the hyrdolysis of the Lys63-linked diubiquitin. Molecular dynamics simulations indicate that the flap in the Trp mutant is quite flexible, allowing almost free rotation of the indole side chain. Therefore, it is possible that these different dynamic

  5. Active load reduction by means of trailing edge flaps on a wind turbine blade

    DEFF Research Database (Denmark)

    Couchman, Ian; Castaignet, Damien; Poulsen, Niels Kjølstad

    2014-01-01

    This paper presents the blade fatigue load reduction achieved with a trailing edge flap during a full scale test on a Vestas V27 wind turbine. A frequency-weighted linear model predictive control (MPC) is tuned to decrease flapwise blade root fatigue loads at the frequencies where most of the blade...... damage occurs, i.e. the 1P and 2P frequencies (respectively 1 and 2 events per revolution). Frequency-weighted MPC is chosen for its ability to handle constraints on the trailing edge flap deflection and to optimise its actuation in order to decrease wear and tear of the actuator. The controller...... was first tested in aero-servo-elastic simulations, before being implemented on a Vestas V27 wind turbine. Consistent load reduction is achieved during the full-scale test. An average of 14% flapwise blade root fatigue load reduction is measured....

  6. Head and neck reconstruction with pedicled flaps in the free flap era.

    Science.gov (United States)

    Mahieu, R; Colletti, G; Bonomo, P; Parrinello, G; Iavarone, A; Dolivet, G; Livi, L; Deganello, A

    2016-12-01

    Nowadays, the transposition of microvascular free flaps is the most popular method for management of head and neck defects. However, not all patients are suitable candidates for free flap reconstruction. In addition, not every defect requires a free flap transfer to achieve good functional results. The aim of this study was to assess whether pedicled flap reconstruction of head and neck defects is inferior to microvascular free flap reconstruction in terms of complications, functionality and prognosis. The records of consecutive patients who underwent free flap or pedicled flap reconstruction after head and neck cancer ablation from 2006 to 2015, from a single surgeon, in the AOUC Hospital, Florence Italy were analysed. A total of 93 patients, the majority with oral cancer (n = 59), were included, of which 64 were pedicled flap reconstructions (69%). The results showed no significant differences in terms of functional outcome, flap necrosis and complications in each type of reconstruction. Multivariate regression analysis of flap necrosis and functional impairments showed no associated factors. Multivariate regression analysis of complicated flap healing showed that only comorbidities remained an explaining factor (p = 0.019). Survival analysis and proportional hazard regression analysis regarding cancer relapse or distant metastasis, showed no significant differences in prognosis of patients concerning both types of reconstruction. In this retrospective, non-randomised study cohort, pedicled flaps were not significantly inferior to free flaps for reconstruction of head and neck defects, considering functionality, complications and prognosis. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  7. Design of flapping wings for application to single active degree of freedom micro air vehicles

    Science.gov (United States)

    Chang, Kelvin Thomas

    This dissertation covers an experimental program to understand how wing compliance influences the performance of flapping micro air vehicle wings. The focus is the design of a membraned flapping wing for a single active degree of freedom mechanism, looking to maximize thrust performance in hover conditions. The optimization approach is unique in that experiments were the chosen engine as opposed to a computation model; this is because of the complexity involved in hover-mode flapping aerodynamics. The flapping mechanism and manufacturing process for fabricating the wings were carefully developed. The uncertainty in the thrust measurement was identified and reduced by implementing precision machining and repeatable techniques for fabrication. This resulted in a reduction of the manufacturing coefficient of variation from 16.8% to 2.6%. Optimization was then conducted for a single objective (Maximize thrust), using a three parameter design space, finding the highest thrust performance in wings with high aspect ratio; then, a multi-objective optimization was conducted with two objectives (Thrust and Power) and a four parameter space. The research then shifted focus to identifying the stiffness and deformation characteristics of high performance wing designs. Static stiffness measurements with a simple line load suggested that high chordwise stiffness or lower spanwise stiffness would be favorable for aerodynamic performance. To explore more components of the deformation, a full-field imaging technique was used and a uniform load was substituted to engage with the membrane. It was found that there is a range of torsional compliance where the wing is most efficient especially at higher flapping frequencies. The final component of the study was the dynamic deformation measurement. The two system, four camera digital image correlation setup uses stroboscopic measurement to capture the wing deformation. The phase shift between the twist and stroke, and the tip deflection

  8. Folding in and out: passive morphing in flapping wings.

    Science.gov (United States)

    Stowers, Amanda K; Lentink, David

    2015-03-25

    We present a new mechanism for passive wing morphing of flapping wings inspired by bat and bird wing morphology. The mechanism consists of an unactuated hand wing connected to the arm wing with a wrist joint. Flapping motion generates centrifugal accelerations in the hand wing, forcing it to unfold passively. Using a robotic model in hover, we made kinematic measurements of unfolding kinematics as functions of the non-dimensional wingspan fold ratio (2-2.5) and flapping frequency (5-17 Hz) using stereo high-speed cameras. We find that the wings unfold passively within one to two flaps and remain unfolded with only small amplitude oscillations. To better understand the passive dynamics, we constructed a computer model of the unfolding process based on rigid body dynamics, contact models, and aerodynamic correlations. This model predicts the measured passive unfolding within about one flap and shows that unfolding is driven by centrifugal acceleration induced by flapping. The simulations also predict that relative unfolding time only weakly depends on flapping frequency and can be reduced to less than half a wingbeat by increasing flapping amplitude. Subsequent dimensional analysis shows that the time required to unfold passively is of the same order of magnitude as the flapping period. This suggests that centrifugal acceleration can drive passive unfolding within approximately one wingbeat in small and large wings. Finally, we show experimentally that passive unfolding wings can withstand impact with a branch, by first folding and then unfolding passively. This mechanism enables flapping robots to squeeze through clutter without sophisticated control. Passive unfolding also provides a new avenue in morphing wing design that makes future flapping morphing wings possibly more energy efficient and light-weight. Simultaneously these results point to possible inertia driven, and therefore metabolically efficient, control strategies in bats and birds to morph or recover

  9. A Mission-Adaptive Variable Camber Flap Control System to Optimize High Lift and Cruise Lift-to-Drag Ratios of Future N+3 Transport Aircraft

    Science.gov (United States)

    Urnes, James, Sr.; Nguyen, Nhan; Ippolito, Corey; Totah, Joseph; Trinh, Khanh; Ting, Eric

    2013-01-01

    Boeing and NASA are conducting a joint study program to design a wing flap system that will provide mission-adaptive lift and drag performance for future transport aircraft having light-weight, flexible wings. This Variable Camber Continuous Trailing Edge Flap (VCCTEF) system offers a lighter-weight lift control system having two performance objectives: (1) an efficient high lift capability for take-off and landing, and (2) reduction in cruise drag through control of the twist shape of the flexible wing. This control system during cruise will command varying flap settings along the span of the wing in order to establish an optimum wing twist for the current gross weight and cruise flight condition, and continue to change the wing twist as the aircraft changes gross weight and cruise conditions for each mission segment. Design weight of the flap control system is being minimized through use of light-weight shape memory alloy (SMA) actuation augmented with electric actuators. The VCCTEF program is developing better lift and drag performance of flexible wing transports with the further benefits of lighter-weight actuation and less drag using the variable camber shape of the flap.

  10. Elbow Reconstruction Using Island Flap for Burn Patients

    Directory of Open Access Journals (Sweden)

    Gi Yeun Hur

    2012-11-01

    Full Text Available BackgroundDeep burns of the elbow lead to soft tissue necrosis and infection, with exposure of deep structures. Adequate wound coverage of this area requires thin, pliable, and durable tissue, while optimal functional recovery requires early coverage and functional rehabilitation. We have found 3 types of island flaps that provide reliable coverage for the elbow.MethodsA retrospective study was performed on all patients who underwent flap coverage of an elbow defect at our hospital. The patients' data including age, sex, cause of injury, wound dimensions, timing of flap coverage, postoperative elbow motion, and complications were investigated.ResultsBetween 2001 and 2012, 16 patients were treated at our hospital. The mean age was 53.3 years. Three kinds of flaps were performed: 9 latissimus dorsi flaps, 4 lateral arm flaps, and 4 radial forearm flaps. The average defect size was 183.5 cm2 (range, 28 to 670 cm2. Wound coverage was performed at mean duration of 45.9 days (range, 14 to 91 days. The mean postoperative active elbow flexion was 98° (range, 85° to 115°. Partial flap failure occurred in 1 latissimus dorsi flap. Minor complications included partial flap loss (11.8%, hematoma (23.5%, seroma (35.3%, and wound infection (5.9%.ConclusionsFlap selection for elbow reconstruction is determined by the defect size and the extent of the adjacent tissue injury. Elbow reconstruction using an island flap is a single-staged, reliable, and relatively simple procedure that permits initiation of early rehabilitation, thereby improving a patient's functional outcome.

  11. Desferrioxamine: a practical method for improving neovascularization of prefabricated flaps.

    Science.gov (United States)

    Li, Bin; Li, Hua; Jin, Rui; Cheng, Chen; Wang, Jing; Zhu, Hainan; Zan, Tao; Li, Qingfeng; Hao, Lijun

    2015-02-01

    Prefabricated flaps are an ideal alternative to repair massive and complex tissue defects. Nevertheless, the risk of necrosis due to unpredictable blood supplies is a major obstacle to the application of prefabricated flaps. The survival of a prefabricated flap depends on the neovascularization between the vascular carrier and the donor tissue. Here, we proposed that the iron chelator, desferrioxamine (DFX), owned therapeutic effects that promoted the neovascularization of prefabricated flaps. An abdominal prefabricated flap model was created in rats via a 2-stage operation. The rats were allocated into 4 groups as follows: 2 groups of rats received DFX treatments during the first or the second stage of the operation, respectively; 1 group of rats received a delay procedure 1 week before the second operation; and the final group was used as a blank control. Flap survival rates and capillary densities were evaluated between groups. The influence of DFX on the dermal fibroblasts was also studied in vitro. Desferrioxamine treatment during the first stage of the operation greatly increased flap survival rate compared to the blank control. The results were similar to those produced by the delay treatment. The vessel count results were consistent with the flap survival rate findings. In vitro, DFX treatment up-regulated the expression levels of several angiogenic factors in the dermal fibroblasts. Nevertheless, DFX treatment during the second stage of the operation was therapeutically detrimental. The application of DFX around the time of vascular carrier implantation greatly promoted neovascularization of prefabricated flaps, but was therapeutically detrimental after the flaps had been elevated.

  12. Effect of Electroacupuncture at The Zusanli Point (Stomach-36) on Dorsal Random Pattern Skin Flap Survival in a Rat Model.

    Science.gov (United States)

    Wang, Li-Ren; Cai, Le-Yi; Lin, Ding-Sheng; Cao, Bin; Li, Zhi-Jie

    2017-10-01

    Random skin flaps are commonly used for wound repair and reconstruction. Electroacupuncture at The Zusanli point could enhance microcirculation and blood perfusion in random skin flaps. To determine whether electroacupuncture at The Zusanli point can improve the survival of random skin flaps in a rat model. Thirty-six male Sprague Dawley rats were randomly divided into 3 groups: control group (no electroacupuncture), Group A (electroacupuncture at a nonacupoint near The Zusanli point), and Group B (electroacupuncture at The Zusanli point). McFarlane flaps were established. On postoperative Day 2, malondialdehyde (MDA) and superoxide dismutase were detected. The flap survival rate was evaluated, inflammation was examined in hematoxylin and eosin-stained slices, and the expression of vascular endothelial growth factor (VEGF) was measured immunohistochemically on Day 7. The mean survival area of the flaps in Group B was significantly larger than that in the control group and Group A. Superoxide dismutase activity and VEGF expression level were significantly higher in Group B than those in the control group and Group A, whereas MDA and inflammation levels in Group B were significantly lower than those in the other 2 groups. Electroacupuncture at The Zusanli point can effectively improve the random flap survival.

  13. Elbow Reconstruction Using Island Flap for Burn Patients

    Directory of Open Access Journals (Sweden)

    Gi Yeun Hur

    2012-11-01

    Full Text Available Background Deep burns of the elbow lead to soft tissue necrosis and infection, with exposureof deep structures. Adequate wound coverage of this area requires thin, pliable, and durabletissue, while optimal functional recovery requires early coverage and functional rehabilitation.We have found 3 types of island flaps that provide reliable coverage for the elbow.Methods A retrospective study was performed on all patients who underwent flap coverageof an elbow defect at our hospital. The patients’ data including age, sex, cause of injury, wounddimensions, timing of flap coverage, postoperative elbow motion, and complications wereinvestigated.Results Between 2001 and 2012, 16 patients were treated at our hospital. The mean agewas 53.3 years. Three kinds of flaps were performed: 9 latissimus dorsi flaps, 4 lateral armflaps, and 4 radial forearm flaps. The average defect size was 183.5 cm2 (range, 28 to 670cm2. Wound coverage was performed at mean duration of 45.9 days (range, 14 to 91 days.The mean postoperative active elbow flexion was 98° (range, 85° to 115°. Partial flap failureoccurred in 1 latissimus dorsi flap. Minor complications included partial flap loss (11.8%,hematoma (23.5%, seroma (35.3%, and wound infection (5.9%.Conclusions Flap selection for elbow reconstruction is determined by the defect size andthe extent of the adjacent tissue injury. Elbow reconstruction using an island flap is a singlestaged,reliable, and relatively simple procedure that permits initiation of early rehabilitation,thereby improving a patient’s functional outcome.

  14. Dynamics of a pneumatic artificial muscle actuation system driving a trailing edge flap

    Science.gov (United States)

    Woods, Benjamin K. S.; Kothera, Curt S.; Wang, Gang; Wereley, Norman M.

    2014-09-01

    This study presents a time domain dynamic model of an antagonistic pneumatic artificial muscle (PAM) driven trailing edge flap (TEF) system for next generation active helicopter rotors. Active rotor concepts are currently being widely researched in the rotorcraft community as a means to provide a significant leap forward in performance through primary aircraft control, vibration mitigation and noise reduction. Recent work has shown PAMs to be a promising candidate for active rotor actuation due to their combination of high force, large stroke, light weight, and suitable bandwidth. When arranged into biologically inspired agonist/antagonist muscle pairs they can produce bidirectional torques for effectively driving a TEF. However, there are no analytical dynamic models in the literature that can accurately capture the behavior of such systems across the broad range of frequencies required for this demanding application. This work combines mechanical, pneumatic, and aerodynamic component models into a global flap system model developed for the Bell 407 rotor system. This model can accurately predict pressure, force, and flap angle response to pneumatic control valve inputs over a range of operating frequencies from 7 to 35 Hz (1/rev to 5/rev for the Bell 407) and operating pressures from 30 to 90 psi.

  15. Dynamics of a pneumatic artificial muscle actuation system driving a trailing edge flap

    International Nuclear Information System (INIS)

    Woods, Benjamin K S; Kothera, Curt S; Wang, Gang; Wereley, Norman M

    2014-01-01

    This study presents a time domain dynamic model of an antagonistic pneumatic artificial muscle (PAM) driven trailing edge flap (TEF) system for next generation active helicopter rotors. Active rotor concepts are currently being widely researched in the rotorcraft community as a means to provide a significant leap forward in performance through primary aircraft control, vibration mitigation and noise reduction. Recent work has shown PAMs to be a promising candidate for active rotor actuation due to their combination of high force, large stroke, light weight, and suitable bandwidth. When arranged into biologically inspired agonist/antagonist muscle pairs they can produce bidirectional torques for effectively driving a TEF. However, there are no analytical dynamic models in the literature that can accurately capture the behavior of such systems across the broad range of frequencies required for this demanding application. This work combines mechanical, pneumatic, and aerodynamic component models into a global flap system model developed for the Bell 407 rotor system. This model can accurately predict pressure, force, and flap angle response to pneumatic control valve inputs over a range of operating frequencies from 7 to 35 Hz (1/rev to 5/rev for the Bell 407) and operating pressures from 30 to 90 psi. (paper)

  16. An innovative method of planning and displaying flap volume in DIEP flap breast reconstructions.

    Science.gov (United States)

    Hummelink, S; Verhulst, Arico C; Maal, Thomas J J; Hoogeveen, Yvonne L; Schultze Kool, Leo J; Ulrich, Dietmar J O

    2017-07-01

    Determining the ideal volume of the harvested flap to achieve symmetry in deep inferior epigastric artery perforator (DIEP) flap breast reconstructions is complex. With preoperative imaging techniques such as 3D stereophotogrammetry and computed tomography angiography (CTA) available nowadays, we can combine information to preoperatively plan the optimal flap volume to be harvested. In this proof-of-concept, we investigated whether projection of a virtual flap planning onto the patient's abdomen using a projection method could result in harvesting the correct flap volume. In six patients (n = 9 breasts), 3D stereophotogrammetry and CTA data were combined from which a virtual flap planning was created comprising perforator locations, blood vessel trajectory and flap size. All projected perforators were verified with Doppler ultrasound. Intraoperative flap measurements were collected to validate the determined flap delineation volume. The measured breast volume using 3D stereophotogrammetry was 578 ± 127 cc; on CTA images, 527 ± 106 cc flap volumes were planned. The nine harvested flaps weighed 533 ± 109 g resulting in a planned versus harvested flap mean difference of 5 ± 27 g (flap density 1.0 g/ml). In 41 out of 42 projected perforator locations, a Doppler signal was audible. This proof-of-concept shows in small numbers that flap volumes can be included into a virtual DIEP flap planning, and transferring the virtual planning to the patient through a projection method results in harvesting approximately the same volume during surgery. In our opinion, this innovative approach is the first step in consequently achieving symmetric breast volumes in DIEP flap breast reconstructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Blowing Flap Experiment: PIV Measurements

    Science.gov (United States)

    Hutcheson, Florence V.; Stead, Daniel J.; Bremmer, David M.

    2004-01-01

    PIV measurements of the flow in the region of a flap side edge are presented for several flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the flap vortex system. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

  18. Experimental Study of Wake / Flap Interaction Noise and the Reduction of Flap Side Edge Noise

    Science.gov (United States)

    Hutcheson, Florence V.; Stead, Daniel J.; Plassman, Gerald E.

    2016-01-01

    The effects of the interaction of a wake with a half-span flap on radiated noise are examined. The incident wake is generated by bars of various widths and lengths or by a simplified landing gear model. Single microphone and phased array measurements are used to isolate the effects of the wake interaction on the noise radiating from the flap side edge and flap cove regions. The effects on noise of the wake generator's geometry and relative placement with respect to the flap are assessed. Placement of the wake generators upstream of the flap side edge is shown to lead to the reduction of flap side edge noise by introducing a velocity deficit and likely altering the instabilities in the flap side edge vortex system. Significant reduction in flap side edge noise is achieved with a bar positioned directly upstream of the flap side edge. The noise reduction benefit is seen to improve with increased bar width, length and proximity to the flap edge. Positioning of the landing gear model upstream of the flap side edge also leads to decreased flap side edge noise. In addition, flap cove noise levels are significantly lower than when the landing gear is positioned upstream of the flap mid-span. The impact of the local flow velocity on the noise radiating directly from the landing gear is discussed. The effects of the landing gear side-braces on flap side edge, flap cove and landing gear noise are shown.

  19. Optimal placement of trailing-edge flaps for helicopter vibration reduction using response surface methods

    Science.gov (United States)

    Viswamurthy, S. R.; Ganguli, Ranjan

    2007-03-01

    This study aims to determine optimal locations of dual trailing-edge flaps to achieve minimum hub vibration levels in a helicopter, while incurring low penalty in terms of required trailing-edge flap control power. An aeroelastic analysis based on finite elements in space and time is used in conjunction with an optimal control algorithm to determine the flap time history for vibration minimization. The reduced hub vibration levels and required flap control power (due to flap motion) are the two objectives considered in this study and the flap locations along the blade are the design variables. It is found that second order polynomial response surfaces based on the central composite design of the theory of design of experiments describe both objectives adequately. Numerical studies for a four-bladed hingeless rotor show that both objectives are more sensitive to outboard flap location compared to the inboard flap location by an order of magnitude. Optimization results show a disjoint Pareto surface between the two objectives. Two interesting design points are obtained. The first design gives 77 percent vibration reduction from baseline conditions (no flap motion) with a 7 percent increase in flap power compared to the initial design. The second design yields 70 percent reduction in hub vibration with a 27 percent reduction in flap power from the initial design.

  20. Wake Characteristics of a Flapping Wing Optimized for both Aerial and Aquatic Flight

    Science.gov (United States)

    Izraelevitz, Jacob; Kotidis, Miranda; Triantafyllou, Michael

    2017-11-01

    Multiple aquatic bird species (including murres, puffins, and other auks) employ a single actuator to propel themselves in two different fluid media: both flying and swimming using primarily their flapping wings. This impressive design compromise could be adopted by engineered implementations of dual aerial/aquatic robotic platforms, as it offers an existence proof for favorable flow physics. We discuss one realization of a 3D flapping wing actuation system for use in both air and water. The wing oscillates by the root and employs an active in-line motion degree-of-freedom. An experiment-coupled optimization routine generates the wing trajectories, controlling the unsteady forces throughout each flapping cycle. We elucidate the wakes of these wing trajectories using dye visualization, correlating the wake vortex structures with simultaneous force measurements. After optimization, the wing generates the large force envelope necessary for propulsion in both fluid media, and furthermore, demonstrate improved control over the unsteady wake.

  1. Effectiveness Using Circular Fibre Steel Flap Gate As a Control Structure Towards the Hydraulic Characteristics in Open Channel

    Science.gov (United States)

    Adib, M. R. M.; Amirza, A. R. M.; Wardah, T.; Junaidah, A.

    2016-07-01

    Hydraulic control gate structure plays an important role in regulating the flow of water in river, canal or water reservoir. One of the most appropriate structures in term of resolving the problem of flood occured is the construction of circular fibre steel flap gate. Therefore, an experiment has been conducted by using an open channel model at laboratory. In this case, hydraulic jump and backwater were the method to determined the hydraulic characteristics of circular fibre steel flap gate in an open channel model. From the experiment, the opening angle of flap gate can receive discharges with the highest flow rate of 0.035 m3/s with opening angle was 47°. The type of jump that occurs at the slope of 1/200 for a distance of 5.0 m is a standing jump or undulating wave. The height of the backwater can be identified based on the differences of specific force which is specific force before jump, F1 and specific force after jump, F2 from the formation of backwater. Based on the research conducted, the tendency of incident backwater wave occurred was high in every distance of water control location from water inlet is flap slope and the slope of 1/300 which is 0.84 m/s and 0.75 m/s of celerity in open channel model.

  2. Design of a high-lift experiment in water including active flow control

    International Nuclear Information System (INIS)

    Beutel, T; Schwerter, M; Büttgenbach, S; Leester-Schädel, M; Sattler, S; El Sayed, Y; Radespiel, R; Zander, M; Sinapius, M; Wierach, P

    2014-01-01

    This paper describes the structural design of an active flow-control experiment. The aim of the experiment is to investigate the increase in efficiency of an internally blown Coanda flap using unsteady blowing. The system uses tailor-made microelectromechanical (MEMS) pressure sensors to determine the state of the oncoming flow and an actuated lip to regulate the mass flow and velocity of a stream near a wall over the internally blown flap. Sensors and actuators are integrated into a highly loaded system that is extremely compact. The sensors are connected to a bus system that feeds the data into a real-time control system. The piezoelectric actuators using the d 33 effect at a comparable low voltage of 120 V are integrated into a lip that controls the blowout slot height. The system is designed for closed-loop control that efficiently avoids flow separation on the Coanda flap. The setup is designed for water-tunnel experiments in order to reduce the free-stream velocity and the system’s control frequency by a factor of 10 compared with that in air. This paper outlines the function and verification of the system’s main components and their development. (technical note)

  3. Application analysis on different suture of scleral flap in trabeculectomy

    Directory of Open Access Journals (Sweden)

    Ning Liu

    2014-05-01

    Full Text Available AIM: To research the application of scleral flap suture in trabeculectomy. METHODS: Totally 114 primary angle-closure glaucoma patients, aged from 36-72 years old, were selected as the objects, and randomly divided into research group and control group. The two groups received different administration methods. Traditional sewing method of sclera flap was used in research group and improved sewing method of sclera flap was used in control group. RESULTS: There was statistical differences between postoperative intraocular pressure of the patients in the observation group and the control group after 1d; 2wk; 1, 3mo(PPP>0.05.CONCLUSION: It is safe and effective that the improved sewing method of sclera flap for trabeculectomy of acute angle-closure glaucoma, and it is a better method to avoid the occurrence of shallow anterior chamber than the traditional sewing method in the early stage after operation.

  4. Addition of Passive Dynamics to a Flapping Airfoil to Improve Performance

    Science.gov (United States)

    Asselin, Daniel; Young, Jay; Williamson, C. H. K.

    2017-11-01

    Animals which fly or swim typically employ flapping motions of their wings and fins in order to produce thrust and to maneuver. Small, unmanned vehicles might also exploit such motions and are of considerable interest for the purposes of surveillance, environmental monitoring, and search and rescue. Flapping refers to a combination of pitch and heave and has been shown to provide good thrust and efficiency (Read, et al. 2003) when both axes are independently controlled (an Active-Active system). In this study, we examine the performance of an airfoil actuated only in the heave direction but allowed to pitch passively under the control of a torsion spring (an Active-Passive system). The presence of the spring is simulated in software using a force-feedback control system called Cyber-Physical Fluid Dynamics, or CPFD (Mackowski & Williamson 2011, 2015, 2016). Adding passive pitch to active heave provides significantly improved thrust and efficiency compared with heaving alone, especially when the torsion spring stiffness is selected so that the system operates near resonance (in an Active-Passive system). In many cases, values of thrust and efficiency are comparable to or better than those obtained with two actively controlled degrees of freedom. By using carefully-designed passive dynamics in the pitch direction, we can eliminate one of the two actuators, saving cost, complexity, and weight, while maintaining performance. This work was supported by the Air Force Office of Scientific Research Grant No. FA9550-15-1-0243, monitored by Dr. Douglas Smith.

  5. The transverse musculocutaneous gracilis flap for breast reconstruction: guidelines for flap and patient selection.

    Science.gov (United States)

    Schoeller, Thomas; Huemer, Georg M; Wechselberger, Gottfried

    2008-07-01

    The transverse musculocutaneous gracilis (TMG) flap has received little attention in the literature as a valuable alternative source of donor tissue in the setting of breast reconstruction. The authors give an in-depth review of their experience with breast reconstruction using the TMG flap. A retrospective review of 111 patients treated with a TMG flap for breast reconstruction in an immediate or a delayed setting between August of 2002 and July of 2007 was undertaken. Of these, 26 patients underwent bilateral reconstruction and 68 underwent unilateral reconstruction, and 17 patients underwent reconstruction unilaterally with a double TMG flap. Patient age ranged between 24 and 65 years (mean, 37 years). Twelve patients had to be taken back to the operating room because of flap-related problems and nine patients underwent successful revision microsurgically, resulting in three complete flap losses in a series of 111 patients with 154 transplanted TMG flaps. Partial flap loss was encountered in two patients, whereas fat tissue necrosis was managed conservatively in six patients. Donor-site morbidity was an advantage of this flap, with a concealed scar and minimal contour irregularities of the thigh, even in unilateral harvest. Complications included delayed wound healing (n = 10), hematoma (n = 5), and transient sensory deficit over the posterior thigh (n = 49). The TMG flap is more than an alternative to the deep inferior epigastric perforator (DIEP) flap in microsurgical breast reconstruction in selected patients. In certain indications, such as bilateral reconstructions, it possibly surpasses the DIEP flap because of a better concealed donor scar and easier harvest.

  6. Structural design optimization of a morphing trailing edge flap for wind turbine blades

    DEFF Research Database (Denmark)

    Barlas, Athanasios; Lin, Yu-Huan; Aagaard Madsen, Helge

    A flap actuation system, the Controllable Rubber Trailing Edge Flap (CRTEF), for distributed load control on a wind turbine blade had been developed in the period from 2006 to 2013 at DTU (http://www.induflap.dk/). The purpose of the presented work is to optimize the structural design of the flex......A flap actuation system, the Controllable Rubber Trailing Edge Flap (CRTEF), for distributed load control on a wind turbine blade had been developed in the period from 2006 to 2013 at DTU (http://www.induflap.dk/). The purpose of the presented work is to optimize the structural design...... of the flexible part of the CRTEF based on a realistic blade section geometry in order to meet the required objectives and constraints. The objectives include the deflection requirements and the energy efficiency, while the constraints include the bending stiffness of the structure, the local shape deformations......, critical material strength, and manufacturing limitations. A model with arches forming concave on the flap surface and enclosing the voids to be pressurized results in the bending movement of the flap when pressure is applied on the voids to straighten the arches. The model is designed using SolidWorks...

  7. Pedicled Temporalis Muscle Flap for Craniofacial Reconstruction: A 35-Year Clinical Experience with 366 Flaps.

    Science.gov (United States)

    Spanio di Spilimbergo, Stefano; Nordera, Paolo; Mardini, Samir; Castiglione, Giusy; Chim, Harvey; Pinna, Vittore; Brunello, Massimo; Cusino, Claudio; Roberto, Squaquara; Baciliero, Ugo

    2017-02-01

    In the past 130 years, the temporalis muscle flap has been used for a variety of different indications. In this age of microsurgery and perforator flaps, the temporalis muscle flap still has many useful applications for craniofacial reconstruction. Three hundred sixty-six temporalis muscle flaps were performed in a single center between 1978 and 2012. The authors divided the cases into two series-before and after 1994-because, after 1994, they started to perform free flap reconstructions, and indications for reconstruction with a temporalis muscle flap were changed RESULTS:: In the series after 1994, flaps were most commonly used for reconstruction of defects in the maxilla, mandible, and oropharynx, in addition to facial reanimation and filling of orbital defects. Complications included total flap necrosis (1.6 percent) and partial flap necrosis (10.7 percent). The rate of material extrusion at the donor site decreased after porous polyethylene was uniformly used for reconstruction from 17.1 to 7.9 percent. The pedicled temporalis muscle flap continues to have many applications in craniofacial reconstruction. With increasing use of free flaps, the authors' indications for the pedicled temporalis muscle flap are now restricted to (1) orbital filling for congenital or acquired anophthalmia; (2) filling of unilateral maxillectomy defects; and (3) facial reanimation in selected cases of facial nerve palsy. Therapeutic, IV.

  8. Head and neck reconstruction with pedicled flaps in the free flap era

    NARCIS (Netherlands)

    Mahieu, R.; Colletti, G.; Bonomo, P.; Parrinello, G.; Iavarone, A.; Dolivet, G.; Livi, L.; Deganello, A.

    2016-01-01

    Nowadays, the transposition of microvascular free flaps is the most popular method for management of head and neck defects. However, not all patients are suitable candidates for free flap reconstruction. In addition, not every defect requires a free flap transfer to achieve good functional results.

  9. Wind Tunnel Testing of Active Control System for Bridges

    DEFF Research Database (Denmark)

    Hansen, Henriette I.; Thoft-Christensen, Palle

    This paper describes preparation of wind tunnel testing of the principle of using flaps to control the motion of suspension bridges. The experiment will take place at the Instituto Superior Technico Lisbon, Portugal. The bridge section model is constructed of foam with an aluminium frame. The flaps...... are regulated by servo motors. Neural networks are used to position the flaps in the optimal positions....

  10. Smart Rotor Modeling: Aero-Servo-Elastic Modeling of a Smart Rotor with Adaptive Trailing Edge Flaps

    DEFF Research Database (Denmark)

    Bergami, Leonardo

    the trailing edge flap deflection to actively reduce the fatigue loads on the structure. The performance of the smart rotor configuration and its control algorithms are finally quantified by aero-servo-elastic simulations of the smart rotor turbine operating in a standard turbulent wind field.......This book presents the formulation of an aero-servo-elastic model for a wind turbine rotor equipped with Adaptive Trailing Edge Flaps (ATEF), a smart rotor configuration. As the name suggests, an aero-servo-elastic model consists of three main components: an aerodynamic model, a structural model......, and a control model. The book first presents an engineering type of aerodynamic model that accounts for the dynamic effects of flap deflection. The aerodynamic model is implemented in a Blade Element Momentum framework, and coupled with a multi-body structural model in the aero-servoelastic simulation code HAWC...

  11. PIV Measurements on a Blowing Flap

    Science.gov (United States)

    Hutcheson, Florence V.; Stead, Daniel J.

    2004-01-01

    PIV measurements of the flow in the region of a flap side edge are presented for several blowing flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main-element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the vortex system or accelerated the merging of the side vortex to the flap top surface. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

  12. Rescue of Primary Incomplete Microkeratome Flap with Secondary Femtosecond Laser Flap in LASIK

    Directory of Open Access Journals (Sweden)

    E. A. Razgulyaeva

    2014-01-01

    Full Text Available For laser-assisted in situ keratomileusis (LASIK retreatments with a previous unsuccessful mechanical microkeratome-assisted surgery, some surgical protocols have been described as feasible, such as relifting of the flap or the creation of a new flap and even the change to a surface ablation procedure (photorefractive keratectomy (PRK. This case shows the use of femtosecond technology for the creation of a secondary flap to perform LASIK in a cornea with a primary incomplete flap obtained with a mechanical microkeratome. As we were unable to characterize the interface of the first partial lamellar cut, a thick flap was planned and created using a femtosecond laser platform. As the primary cut was very thick in the nasal quadrant, a piece of loose corneal tissue appeared during flap lifting which was fitted in its position and not removed. Despite this condition and considering the regularity of the new femtosecond laser cut, the treatment was uneventful. This case report shows the relevance of a detailed corneal analysis with an advanced imaging technique before performing a secondary flap in a cornea with a primary incomplete flap. The femtosecond laser technology seems to be an excellent tool to manage such cases successfully.

  13. Innovation in the planning of V-Y rotation advancement flaps: A template for flap design

    Directory of Open Access Journals (Sweden)

    Utku Can Dölen

    2018-01-01

    Full Text Available Local flaps exhibit excellent color matching that no other type of flap can compete with. Moreover, surgery using a local flap is easier and faster than surgery using a distant or free flap. However, local flaps can be much more difficult to design. We designed 2 templates to plan a V-Y rotation advancement flap. The template for a unilateral V-Y rotation advancement flap was used on the face (n=5, anterior tibia (n=1, posterior axilla (n=1, ischium (n=1, and trochanter (n=2. The template for a bilateral flap was used on the sacrum (n=8, arm (n=1, and anterior tibia (n=1. The causes of the defects were meningocele (n=3, a decubitus ulcer (n=5, pilonidal sinus (n=3, and skin tumor excision (n=10. The meningocele patients were younger than 8 days. The mean age of the adult patients was 50.4 years (range, 19–80 years. All the donor areas of the flaps were closed primarily. None of the patients experienced wound dehiscence or partial/total flap necrosis. The templates guided surgeons regarding the length and the placement of the incision for a V-Y rotation advancement flap according to the size of the wound. In addition, they could be used for the training of residents.

  14. Navier-Stokes Computations of a Wing-Flap Model With Blowing Normal to the Flap Surface

    Science.gov (United States)

    Boyd, D. Douglas, Jr.

    2005-01-01

    A computational study of a generic wing with a half span flap shows the mean flow effects of several blown flap configurations. The effort compares and contrasts the thin-layer, Reynolds averaged, Navier-Stokes solutions of a baseline wing-flap configuration with configurations that have blowing normal to the flap surface through small slits near the flap side edge. Vorticity contours reveal a dual vortex structure at the flap side edge for all cases. The dual vortex merges into a single vortex at approximately the mid-flap chord location. Upper surface blowing reduces the strength of the merged vortex and moves the vortex away from the upper edge. Lower surface blowing thickens the lower shear layer and weakens the merged vortex, but not as much as upper surface blowing. Side surface blowing forces the lower surface vortex farther outboard of the flap edge by effectively increasing the aerodynamic span of the flap. It is seen that there is no global aerodynamic penalty or benefit from the particular blowing configurations examined.

  15. The Versatile Modiolus Perforator Flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Thomsen, Jorn Bo

    2016-01-01

    BACKGROUND: Perforator flaps are well established, and their usefulness as freestyle island flaps is recognized. The whereabouts of vascular perforators and classification of perforator flaps in the face are a debated subject, despite several anatomical studies showing similar consistency. In our...... experience using freestyle facial perforator flaps, we have located areas where perforators are consistently found. This study is focused on a particular perforator lateral to the angle of the mouth; the modiolus and the versatile modiolus perforator flap. METHODS: A cohort case series of 14 modiolus...... perforator flap reconstructions in 14 patients and a color Doppler ultrasonography localization of the modiolus perforator in 10 volunteers. RESULTS: All 14 flaps were successfully used to reconstruct the defects involved, and the location of the perforator was at the level of the modiolus as predicted...

  16. Venous coupler use for free-flap breast reconstructions: specific analyses of TMG and DIEP flaps.

    Science.gov (United States)

    Bodin, Frédéric; Brunetti, Stefania; Dissaux, Caroline; Erik, A Sauleau; Facca, Sybille; Bruant-Rodier, Catherine; Liverneaux, Philippe

    2015-05-01

    The purpose of this report was to present the results of comparisons of anastomotic data and flap complications in the use of venous coupler in breast reconstruction with the transverse musculocutaneous gracilis (TMG) flap and the deep inferior epigastric perforator (DIEP) flap. Over a three-year period, 95 patients suffering from breast cancer were treated with mastectomy and breast reconstruction using free flaps. We performed 121 mechanical venous anastomoses for 105 flap procedures (80 DIEP and 25 TMG). The coupler size, anastomotic duration, number of anastomoses and postoperative complications were assessed for the entire series. The coupling device was perfectly suitable for all end-to-end anastomoses between the vein(s) of the flap and the internal mammary vein(s). No venous thrombosis occurred. The mean anastomotic time did not significantly differ between the DIEP (330 seconds) and TMG flap procedures (352 seconds) (P = 0.069). Additionally, there were no differences in coupling time observed following a comparison of seven coupler sizes (P = 0.066). The mean coupler size used during the TMG flap procedure was smaller than that used with the DIEP (2.4 mm versus 2.8 mm) (P TMG flap (28%) than with the DIEP flap (11%). The coupler size used was smaller for the TMG procedure and when double venous anastomosis was performed. Additionally, anastomotic time was not affected by the flap type or coupler size used or by anastomosis number. © 2014 Wiley Periodicals, Inc.

  17. Face resurfacing using a cervicothoracic skin flap prefabricated by lateral thigh fascial flap and tissue expander.

    Science.gov (United States)

    Li, Qingfeng; Zan, Tao; Gu, Bin; Liu, Kai; Shen, Guoxiong; Xie, Yun; Weng, Rui

    2009-01-01

    Resurfacing of facial massive soft tissue defect is a formidable challenge because of the unique character of the region and the limitation of well-matched donor site. In this report, we introduce a technique for using the prefabricated cervicothoracic skin flap for facial resurfacing, in an attempt to meet the principle of flap selection in face reconstructive surgery for matching the color and texture, large dimension, and thinner thickness (MLT) of the recipient. Eleven patients with massive facial scars underwent resurfacing procedures with prefabricated cervicothoracic flaps. The vasculature of the lateral thigh fascial flap, including the descending branch of the lateral femoral circumflex vessels and the surrounding muscle fascia, was used as the vascular carrier, and the pedicles of the fascial flap were anastomosed to either the superior thyroid or facial vessels in flap prefabrication. A tissue expander was placed beneath the fascial flap to enlarge the size and reduce the thickness of the flap. The average size of the harvested fascia flap was 6.5 x 11.7 cm. After a mean interval of 21.5 weeks, the expanders were filled to a mean volume of 1,685 ml. The sizes of the prefabricated skin flaps ranged from 12 x 15 cm to 15 x 32 cm. The prefabricated skin flaps were then transferred to the recipient site as pedicled flaps for facial resurfacing. All facial soft tissue defects were successfully covered by the flaps. The donor sites were primarily closed and healed without complications. Although varied degrees of venous congestion were developed after flap transfers, the marginal necrosis only occurred in two cases. The results in follow-up showed most resurfaced faces restored natural contour and regained emotional expression. MLT is the principle for flap selection in resurfacing of the massive facial soft tissue defect. Our experience in this series of patients demonstrated that the prefabricated cervicothoracic skin flap could be a reliable alternative

  18. The Effect of Omeprazole Usage on the Viability of Random Pattern Skin Flaps in Rats.

    Science.gov (United States)

    Şen, Hilmi; Oruç, Melike; Işik, Veysel Murat; Sadiç, Murat; Sayar, Hamide; Çitil, Rana; Korkmaz, Meliha; Koçer, Uğur

    2017-06-01

    Necrosis of random pattern flaps caused by inadequate blood flow, especially in the distal part of the flap is one of the biggest challenges in reconstructive surgery. Various agents have been used to prevent flap ischemia. In this study, we used omeprazole, which is a potent inhibitor of gastric acidity to increase flap viability. In this study, 35 Wistar-Albino type rats which were divided into 5 equal groups were used. Random-pattern dorsal skin flaps were raised in all groups at seventh day of the study. Group 1 was accepted as control group, and the rats in this group was only given distilled water intraperitoneally for 14 days. Group 2 and group 3 received 10 and 40 mg/kg omeprazole daily for 14 days, respectively. Group 4 and group 5 were given distilled water for the first 7 days and then after the operations they received 10 and 40 mg/kg omeprazole daily for 7 days, respectively. Survival rates of the flaps were examined seventh day after elevation of the flaps by digital imaging and scintigraphy. After assessment of the amount of necrosis, number of vascular structures were counted histopathologically. Percentage of flap necrosis was found to be less in all omeprazole received groups. On digital imaging, percentages of flap necrosis in the study groups were statistically significantly lower than that of the control group (P 0.05).In the histopathologic specimens, it was detected that the mean number of vessels in proximal (a) and distal (c) portions of the flap in the study groups showed a significant increase when compared with the control group (P usage of medications increasing gastrin during flap surgeries can be thought as a positive contributor. In this sense, this study showed that parenteral administration of omeprazole in skin flap surgery increases flap viability possibly by increasing gastrin levels.

  19. Comparison of gluteal perforator flaps and gluteal fasciocutaneous rotation flaps for reconstruction of sacral pressure sores.

    Science.gov (United States)

    Chen, Yen-Chou; Huang, Eng-Yen; Lin, Pao-Yuan

    2014-03-01

    The gluteus maximus myocutaneous flap was considered the workhorse that reconstructed sacral pressure sores, but was gradually replaced by fasciocutaneous flap because of several disadvantages. With the advent of the perforator flap technique, gluteal perforator (GP) flap has gained popularity nowadays. The aim of this study was to compare the complications and outcomes between GP flaps and gluteal fasciocutaneous rotation (FR) flaps in the treatment of sacral pressure sores. Between April 2007 and June 2012, 63 patients underwent sacral pressure sore reconstructions, with a GP flap used in 31 cases and an FR flap used in 32 cases. Data collected on the patients included patient age, gender, co-morbidity for being bedridden and follow-up time. Surgical details collected included the defect size, operative time and estimated blood loss. Complications recorded included re-operation, dehiscence, flap necrosis, wound infection, sinus formation, donor-site morbidity and recurrence. The complications and clinical outcomes were compared between these two groups. We found that there was no significant difference in patient demographics, surgical complications and recurrence between these two groups. In gluteal FR flap group, all recurrent cases (five) were treated by reuse of previous flaps. Both methods are comparable, good and safe in treating sacral pressure sores. Gluteal FR flap can be performed without microsurgical dissection, and re-rotation is feasible in recurrent cases. The authors suggest using gluteal FR flaps in patients with a high risk of sore recurrence. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Towards an industrial manufactured morphing trailing edge flap system for wind turbines

    OpenAIRE

    Aagaard Madsen , Helge; Løgstrup Andersen, Tom; Bergami, Leonardo; Jørgensen, Johnny Egtved; Candela Garolera, Anna; Holbøll, Joachim; Schettler, T.; Michels, P.; Schoebel, M.; Heisterberg, M.; Christensen, M.B.

    2014-01-01

    A flap actuation system, the Controllable Rubber Trailing Edge Flap (CRTEF), for distributed load control on a wind turbine blade has been developed in the period from 2006 to 2010 at DTU. The function of the system and its capability to change the lift on a blade section was measured during a wind tunnel experiment in 2009 with promising results. This led in 2011 to initiation of a new research project INDUFLAP with the main aim to transfer the flap technology to industry as concerns manufac...

  1. Clinical observation of the glaucoma trabeculectomy with tunnel knife making the double-deck scleral flap

    Directory of Open Access Journals (Sweden)

    Min Fu

    2015-07-01

    Full Text Available AIM: To study the trabeculectomy clinical effect of use tunnel knife to make double-deck scleral flap and to cut off the layer scleral flap of glaucoma.METHODS:Using the random grouping method to divide 46 cases(60 eyesof glaucoma into the treatment group of 24 cases(32 eyesand control group of 22 cases(28 eyes. The treatment group, tunnel knife was used to make double-deck sclera flap and superficial scleral flap about the size of 5mm×5.5mm,1/3 scleral thickness, under the sclera flap made another one about the size of 3.5mm×4mm, 1/3 scleral thickness, resected the middle layer of the sclera flap, removed 2mm×2mm trabecular tissue, underwent routine peripheral iridectomy, could adjust suture the superficial scleral flap, sutured Ball fascia and bulbar conjunctiva. In control group, routine glaucoma trabeculectomy was undergone.RESULTS:Patients were followed up for 1a, the vision in treatment group was obviously better than that in the control group, with a statistically significant difference(PP>0.05. But after 6 and 12mo, the intraocular pressure of the treatment group were significantly lower than that of the control group, with statistically significant difference(PPCONCLUSION:The trabeculectomy have a good effect to lower the intraocular pressure by use tunnel knife to make double-deck scleral flap and to cut off the layer scleral flap. The scleral flap have uniform thickness, smooth surface, and the function of the filtering bleb maintained for a long time, less postoperative complications, suitable for various types of glaucoma, so it is worthy of clinical promotion.

  2. Efficient flapping flight of pterosaurs

    Science.gov (United States)

    Strang, Karl Axel

    In the late eighteenth century, humans discovered the first pterosaur fossil remains and have been fascinated by their existence ever since. Pterosaurs exploited their membrane wings in a sophisticated manner for flight control and propulsion, and were likely the most efficient and effective flyers ever to inhabit our planet. The flapping gait is a complex combination of motions that sustains and propels an animal in the air. Because pterosaurs were so large with wingspans up to eleven meters, if they could have sustained flapping flight, they would have had to achieve high propulsive efficiencies. Identifying the wing motions that contribute the most to propulsive efficiency is key to understanding pterosaur flight, and therefore to shedding light on flapping flight in general and the design of efficient ornithopters. This study is based on published results for a very well-preserved specimen of Coloborhynchus robustus, for which the joints are well-known and thoroughly described in the literature. Simplifying assumptions are made to estimate the characteristics that can not be inferred directly from the fossil remains. For a given animal, maximizing efficiency is equivalent to minimizing power at a given thrust and speed. We therefore aim at finding the flapping gait, that is the joint motions, that minimize the required flapping power. The power is computed from the aerodynamic forces created during a given wing motion. We develop an unsteady three-dimensional code based on the vortex-lattice method, which correlates well with published results for unsteady motions of rectangular wings. In the aerodynamic model, the rigid pterosaur wing is defined by the position of the bones. In the aeroelastic model, we add the flexibility of the bones and of the wing membrane. The nonlinear structural behavior of the membrane is reduced to a linear modal decomposition, assuming small deflections about the reference wing geometry. The reference wing geometry is computed for

  3. Control strategy of an electrically actuated morphing flap for the next generation green regional aircraft

    Science.gov (United States)

    Arena, Maurizio; Noviello, Maria Chiara; Rea, Francesco; Amoroso, Francesco; Pecora, Rosario

    2018-03-01

    The design and application of adaptive devices are currently ambitious targets in the field of aviation research addressed at new generation aircraft. The development of intelligent structures involves aspects of multidisciplinary nature: the combination of compact architectures, embedded electrical systems and smart materials, allows for developing a highly innovative device. The paper aims to present the control system design of an innovative morphing flap tailored for the next generation regional aircraft, within Clean Sky 2 - Airgreen 2 European Research Scenario. A distributed system of electromechanical actuators (EMAs) has been sized to enable up to three operating modes of a structure arranged in four blocks along the chord-wise direction: •overall camber-morphing; •upwards/downwards deflection and twisting of the final tip segment. A state-of-art feedback logic based on a decentralized control strategy for shape control is outlined, including the results of dynamic stability analysis based on the blocks rational schematization within Matlab/Simulink® environment. Such study has been performed implementing a state-space model, considering also design parameters as the torsional stiffness and damping of the actuation chain. The design process is flowing towards an increasingly "robotized" system, which can be externally controlled to perform certain operations. Future developments will be the control laws implementation as well as the functionality test on a real flap prototype.

  4. Aeroelastic Stability of a 2D Airfoil Section equipped with a Trailing Edge Flap

    DEFF Research Database (Denmark)

    Bergami, Leonardo

    Recent studies conclude that important reduction of the fatigue loads encountered by a wind turbine blade can be achieved using a deformable trailing edge control system. The focus of the current work is to determine the effect of this flap-like system on the aeroelastic stability of a 2D airfoil...... section. A simulation tool is implemented to predict the flow speed at which a flap equipped section may become unstable, either due to flutter or divergence. First, the stability limits of the airfoil without flap are determined, and, in the second part of the work, a deformable trailing edge flap...... is applied. Stability is investigated for the uncontrolled flap, and for three different control algorithms. The three controls are tuned for fatigue load alleviation and they are based on, respectively, measurement of the heave displacement and velocity, measurement of the local angle of attack, measurement...

  5. Development of an Extracorporeal Perfusion Device for Small Animal Free Flaps.

    Directory of Open Access Journals (Sweden)

    Andreas M Fichter

    Full Text Available Extracorporeal perfusion (ECP might prolong the vital storage capabilities of composite free flaps, potentially opening a wide range of clinical applications. Aim of the study was the development a validated low-cost extracorporeal perfusion model for further research in small animal free flaps.After establishing optimal perfusion settings, a specially designed extracorporeal perfusion system was evaluated during 8-hour perfusion of rat epigastric flaps followed by microvascular free flap transfer. Controls comprised sham-operation, ischemia and in vivo perfusion. Flaps and perfusate (diluted blood were closely monitored by blood gas analysis, combined laser Doppler flowmetry and remission spectroscopy and Indocyanine-Green angiography. Evaluations were complemented by assessment of necrotic area and light microscopy at day 7.ECP was established and maintained for 8 hours with constant potassium and pH levels. Subsequent flap transfer was successful. Notably, the rate of necrosis of extracorporeally perfused flaps (27% was even lower than after in vivo perfusion (49%, although not statistically significant (P = 0,083. After sham-operation, only 6% of the total flap area became necrotic, while 8-hour ischemia led to total flap loss (98%. Angiographic and histological findings confirmed these observations.Vital storage capabilities of microvascular flaps can be prolonged by temporary ECP. Our study provides important insights on the pathophysiological processes during extracorporeal tissue perfusion and provides a validated small animal perfusion model for further studies.

  6. Aeroservoelastic stability of a 2D airfoil section equipped with a trailing edge flap

    Energy Technology Data Exchange (ETDEWEB)

    Bergami, Leonardo

    2008-11-15

    Recent studies conclude that important reduction of the fatigue loads encountered by a wind turbine blade can be achieved using a deformable trailing edge control system. The focus of the current work is to determine the effect of this flap-like system on the aeroelastic stability of a 2D airfoil section. A simulation tool is implemented to predict the flow speed at which a flap equipped section may become unstable, either due to flutter or divergence. First, the stability limits of the airfoil without flap are determined, and, in the second part of the work, a deformable trailing edge flap is applied. Stability is investigated for the uncontrolled flap, and for three different control algorithms. The three controls are tuned for fatigue load alleviation and they are based on, respectively, measurement of the heave displacement and velocity, measurement of the local angle of attack, measurement of the pressure difference between the two sides of the airfoil. The stability of the aeroservoelastic system in a defined equilibrium state, and for a given flow speed, is then determined by solving an eigenvalue problem. Results show that the trailing edge control system modifies significantly the stability limits of the section. In the investigated case, increased flutter limits are reported when the elastic flap is left without control, whereas, by applying any of the control algorithms, the flutter velocity is reduced. Nevertheless, only in the heave control case the flutter limit becomes critically close to normal operation flow speeds. Furthermore, a marked dependence of the stability limits on the control gain is also observed and, by tuning the gain parameters, flutter and divergence can be suppressed for flow speed even above the flutter velocity encountered with uncontrolled flap. (author)

  7. The Pedicled LICAP Flap Combined with a Free Abdominal Flap In Autologous Breast Reconstructions

    Directory of Open Access Journals (Sweden)

    Thomas Sjøberg, MD

    2018-01-01

    Conclusion:. In selected patients with insufficient abdominal flap tissue, a combination of a free abdominal flap and a pedicled LICAP flap is a valuable option to increase breast size and cosmetic outcome. Additional symmetrizing surgery might still be necessary.

  8. Comparison of Dorsal Intercostal Artery Perforator Propeller Flaps and Bilateral Rotation Flaps in Reconstruction of Myelomeningocele Defects.

    Science.gov (United States)

    Tenekeci, Goktekin; Basterzi, Yavuz; Unal, Sakir; Sari, Alper; Demir, Yavuz; Bagdatoglu, Celal; Tasdelen, Bahar

    2018-04-09

    Bilateral rotation flaps are considered the workhorse flaps in reconstruction of myelomeningocele defects. Since the introduction of perforator flaps in the field of reconstructive surgery, perforator flaps have been used increasingly in the reconstruction of various soft tissue defects all over the body because of their appreciated advantages. The aim of this study was to compare the complications and surgical outcomes between bilateral rotation flaps and dorsal intercostal artery perforator (DICAP) flaps in the soft tissue reconstruction of myelomeningocele defects. Between January 2005-February 2017, we studied 47 patients who underwent reconstruction of myelomeningocele defects. Patient demographics, operative data, and postoperative data were reviewed retrospectively and are included in the study. We found no statistically significant differences in patient demographics and surgical complications between these two groups; this may be due to small sample size. With regard to complications-partial flap necrosis, cerebrospinal fluid (CSF) leakage, necessity for reoperation, and wound infection-DICAP propeller flaps were clinically superior to rotation flaps. Partial flap necrosis was associated with CSF leakage and wound infection, and CSF leakage was associated with wound dehiscence. Although surgical outcomes obtained with DICAP propeller flaps were clinically superior to those obtained with rotation flaps, there was no statistically significant difference between the two patient groups. A well-designed comparative study with adequate sample size is needed. Nonetheless, we suggest using DICAP propeller flaps for reconstruction of large myelomeningocele defects.

  9. Blood flow autoregulation in pedicled flaps

    DEFF Research Database (Denmark)

    Bonde, Christian T; Holstein-Rathlou, Niels-Henrik; Elberg, Jens J

    2009-01-01

    was to evaluate if, and to what extent, a tissue flap could compensate a reduction in blood flow due to an acute constriction of the feed artery. Further, we wanted to examine the possible role of smooth muscle L-type calcium channels in the autoregulatory mechanism by pharmacological intervention with the L......, the flow in the pedicle was reduced and the flow was recorded. RESULTS: The flaps showed a strong autoregulatory response with complete compensation for flow reductions of up to 70-80%. Infusion of nimodipine caused a 28+/-10% increase in blood flow and removed the autoregulation. Papaverine caused...... a further increase in blood flow by 61+/-19%. The time control experiments proved that the experimental procedure was reproducible and stable over time. CONCLUSIONS: A tissue flap can nearly completely compensate for repeated flow reductions of up to 70-80%. This is due to a decrease in the peripheral...

  10. Total endoscopic free flap harvest of a serratus anterior fascia flap for microsurgical lower leg reconstruction

    Directory of Open Access Journals (Sweden)

    Erdmann, Alfons

    2014-04-01

    Full Text Available [english] Background: A tremendous number of free flaps have been developed in the past. As the surgical result depends not only on a successful flap transfer but also on the harvest, this paper details the procedures for undertaking the first total endoscopic harvest of a serratus fascia flap for free flap transplantation to the lower leg. Patient and methods: In September 2012 we performed the first total endoscopic serratus anterior fascia free flap harvest. The incision of 2.5 cm length was made 10 cm in front of anterior muscle border of the latissimus dorsi at level with the midthorax. After insertion of a flexible laparoscopic single port system we started CO gas insufflation. We used this setting to meticulously prepare a neo cavity between atissimus dorsi and M. serratus anterior. The vessels were dissected and the thoraco-dorsal nerve was separated. With a second auxiliary incision we used a clamp to support the raising of the fascia flap from the underlying muscle. Finally we clipped the vessels to the latissimus dorsi muscle and the flap vessels at the Arteria and Vena axillaris. The flap was extracted via the 2.5 cm incision.Results: We were able to perform a total endoscopic harvest of a serratus fascia flap for free flap reconstruction of soft tissues. With this new operative technique we were able to avoid a long skin incision, which in our view lowers the morbidity at the harvest area.Conclusion: We describe a new method for the total endoscopic harvest of the serratus fascia flap for free flap transfer. The flap was harvested within reasonable time and following surgery leaves the patient with minimal donor site morbidity compared to the open technique.

  11. Propeller Flaps: A Literature Review.

    Science.gov (United States)

    Sisti, Andrea; D'Aniello, Carlo; Fortezza, Leonardo; Tassinari, Juri; Cuomo, Roberto; Grimaldi, Luca; Nisi, Giuseppe

    2016-01-01

    Since their introduction in 1991, propeller flaps are increasingly used as a surgical approach to loss of substance. The aim of this study was to evaluate the indications and to verify the outcomes and the complication rates using this reconstructing technique through a literature review. A search on PubMed was performed using "propeller flap", "fasciocutaneous flap", "local flap" or "pedicled flap" as key words. We selected clinical studies using propeller flaps as a reconstructing technique. We found 119 studies from 1991 to 2015. Overall, 1,315 propeller flaps were reported in 1,242 patients. Most frequent indications included loss of substance following tumor excision, repair of trauma-induced injuries, burn scar contractures, pressure sores and chronic infections. Complications were observed in 281/1242 patients (22.6%) occurring more frequently in the lower limbs (31.8%). Partial flap necrosis and venous congestion were the most frequent complications. The complications' rate was significantly higher in infants (70 years old) but there was not a significant difference between the sexes. Trend of complication rate has not improved during the last years. Propeller flaps showed a great success rate with low morbidity, quick recovery, good aesthetic outcomes and reduced cost. The quality and volume of the transferred soft tissue, the scar orientation and the possibility of direct donor site closure should be considered in order to avoid complications. Indications for propeller flaps are small- or medium-sized defects located in a well-vascularized area with healthy surrounding tissues. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  12. The freestyle pedicle perforator flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Jackson, Ian T; Westvik, Tormod S

    2015-01-01

    BACKGROUND: Perforating vessels are a consistent anatomical finding and well described in the current literature. Any skin flap can be raised on a subcutaneous pedicle as long as it contains at least one supplying perforator. Perforator flaps have been interlinked with microsurgery and generally...... not widely performed by the general plastic surgeons. The aim of this paper is to present the simplicity of pedicled perforator flap reconstruction of moderate-sized defects of the extremities and torso. METHODS: We retrospectively reviewed the charts of 34 patients reconstructed using 34 freestyle pedicled...... perforator flaps for moderate-sized defects of the truncus and extremities. We registered indications, flap size and localization, success rate, and complications. Most importantly, we describe a simple approach to the design of freestyle pedicled perforator flaps and elaborate on technical aspects...

  13. Continuous Trailing-Edge Flaps for Primary Flight Control of a Helicopter Main Rotor

    Science.gov (United States)

    Thornburgh, Robert P.; Kreshock, Andrew R.; Wilbur, Matthew L.; Sekula, Martin K.; Shen, Jinwei

    2014-01-01

    The use of continuous trailing-edge flaps (CTEFs) for primary flight control of a helicopter main rotor is studied. A practical, optimized bimorph design with Macro-Fiber Composite actuators is developed for CTEF control, and a coupled structures and computational fluid dynamics methodology is used to study the fundamental behavior of an airfoil with CTEFs. These results are used within a comprehensive rotorcraft analysis model to study the control authority requirements of the CTEFs when utilized for primary flight control of a utility class helicopter. A study of the effect of blade root pitch index (RPI) on CTEF control authority is conducted, and the impact of structural and aerodynamic model complexity on the comprehensive analysis results is presented. The results show that primary flight control using CTEFs is promising; however, a more viable option may include the control of blade RPI, as well.

  14. Design and stable flight of a 21 g insect-like tailless flapping wing micro air vehicle with angular rates feedback control.

    Science.gov (United States)

    Phan, Hoang Vu; Kang, Taesam; Park, Hoon Cheol

    2017-04-04

    An insect-like tailless flapping wing micro air vehicle (FW-MAV) without feedback control eventually becomes unstable after takeoff. Flying an insect-like tailless FW-MAV is more challenging than flying a bird-like tailed FW-MAV, due to the difference in control principles. This work introduces the design and controlled flight of an insect-like tailless FW-MAV, named KUBeetle. A combination of four-bar linkage and pulley-string mechanisms was used to develop a lightweight flapping mechanism that could achieve a high flapping amplitude of approximately 190°. Clap-and-flings at dorsal and ventral stroke reversals were implemented to enhance vertical force. In the absence of a control surface at the tail, adjustment of the location of the trailing edges at the wing roots to modulate the rotational angle of the wings was used to generate control moments for the attitude control. Measurements by a 6-axis load cell showed that the control mechanism produced reasonable pitch, roll and yaw moments according to the corresponding control inputs. The control mechanism was integrated with three sub-micro servos to realize the pitch, roll and yaw controls. A simple PD feedback controller was implemented for flight stability with an onboard microcontroller and a gyroscope that sensed the pitch, roll and yaw rates. Several flight tests demonstrated that the tailless KUBeetle could successfully perform a vertical climb, then hover and loiter within a 0.3 m ground radius with small variations in pitch and roll body angles.

  15. Optimal propulsive flapping in Stokes flows.

    Science.gov (United States)

    Was, Loïc; Lauga, Eric

    2014-03-01

    Swimming fish and flying insects use the flapping of fins and wings to generate thrust. In contrast, microscopic organisms typically deform their appendages in a wavelike fashion. Since a flapping motion with two degrees of freedom is able, in theory, to produce net forces from a time-periodic actuation at all Reynolds numbers, we compute in this paper the optimal flapping kinematics of a rigid spheroid in a Stokes flow. The hydrodynamics for the force generation and energetics of the flapping motion is solved exactly. We then compute analytically the gradient of a flapping efficiency in the space of all flapping gaits and employ it to derive numerically the optimal flapping kinematics as a function of the shape of the flapper and the amplitude of the motion. The kinematics of optimal flapping are observed to depend weakly on the flapper shape and are very similar to the figure-eight motion observed in the motion of insect wings. Our results suggest that flapping could be a exploited experimentally as a propulsion mechanism valid across the whole range of Reynolds numbers.

  16. Optimal propulsive flapping in Stokes flows

    International Nuclear Information System (INIS)

    Was, Loïc; Lauga, Eric

    2014-01-01

    Swimming fish and flying insects use the flapping of fins and wings to generate thrust. In contrast, microscopic organisms typically deform their appendages in a wavelike fashion. Since a flapping motion with two degrees of freedom is able, in theory, to produce net forces from a time-periodic actuation at all Reynolds numbers, we compute in this paper the optimal flapping kinematics of a rigid spheroid in a Stokes flow. The hydrodynamics for the force generation and energetics of the flapping motion is solved exactly. We then compute analytically the gradient of a flapping efficiency in the space of all flapping gaits and employ it to derive numerically the optimal flapping kinematics as a function of the shape of the flapper and the amplitude of the motion. The kinematics of optimal flapping are observed to depend weakly on the flapper shape and are very similar to the figure-eight motion observed in the motion of insect wings. Our results suggest that flapping could be a exploited experimentally as a propulsion mechanism valid across the whole range of Reynolds numbers. (paper)

  17. [The influence of estradiol on histomorphology of skin flaps with ischemia reperfusion injury].

    Science.gov (United States)

    Jianlong, Wu; Ruixing, Hou; Guangliang, Zhou; Jihui, Ju

    2015-09-01

    To study the influence of estradiol on histomorphology of skin flaps with ischemia reperfusion injury. 48 adult male Wistar rats aged 12-14 weeks old, were randomly divided into control group (group I), ischemia-reperfusion group (group II), saline group (group III), estradiol group (group IV). Superficial epigastric artery axial flap, 3 cm x 6 cm in size, was made in the left lower quadrant abdominal of each rat. Flap model with ischemia-reperfusion injury was established by using the nondestructive micro vascular clamp to clamp the superficial epigastric artery. The general condition of the flap was observed after operation. At 7 days after operation, the survival rate of the flap was detected, the flaps were harvested to receive histology and ultrastructural observation. The neutrophils level of the superficial epigastric vein were tested. 7 days after operation, the survival rate of the flap in group IV was significantly higher than that in group II, III (P organization structure in flap.

  18. [A variant of island flaps for the covering of pressure sores: the hatchet flap. Apropos of 31 cases].

    Science.gov (United States)

    Quillot, M; Lodde, J P; Pegorier, O; Reynaud, J P; Cormerais, A

    1994-08-01

    The authors propose a modification of the classical design of island flaps for cover of pressure sores, applied to gluteus maximus and tensor fascia lata muscles: the hatchet flap. 31 flaps have been used including 13 gluteus maximus superior flaps for sacral pressure sores, 9 gluteal inferior flaps for ischial pressure sores and 9 tensor fascia lata flaps for trochanteric pressure sores. A small partial necrosis and two cases of sepsis were observed in this series, but did not require surgical revision. The authors emphasize the value of this modification of the classical flap design, which preserves an even better musculocutaneous capital in these patients, who are often already multi-operated. The very rapid recovery of patients supports the authors' application of hatchet flaps to the surgery of pressure sores, and suggests the extension to other musculocutaneous flaps in the future.

  19. Efficacy of In Vivo Electroporation-Mediated IL-10 Gene Delivery on Survival of Skin Flaps.

    Science.gov (United States)

    Seyed Jafari, S Morteza; Shafighi, Maziar; Beltraminelli, Helmut; Weber, Benedikt; Schmid, Ralph A; Geiser, Thomas; Gazdhar, Amiq; Hunger, Robert E

    2018-04-01

    Despite advances in understanding the underlying mechanisms of flap necrosis and improvement in surgical techniques, skin flap necrosis after reconstructive surgery remains a crucial issue. We investigated the efficacy of electroporation-mediated IL-10 gene transfer to random skin flap with an aim to accelerate wound healing and improve skin flap survival. Nine male Wistar rats (300-330 g) were divided in two groups (a) control group (n = 5), only surgery no gene transfer, and (b) experimental group, received electroporation-mediated IL-10 gene transfer 24 h before the surgery as prophylaxis (n = 4). Random skin flap (McFarlane) was performed in both groups. Planimetry, Laser Doppler imaging, and immunohistochemistry were used to evaluate the effect of IL-10 gene transfer between study groups at day 7. Electroporation-mediated IL-10 gene transfer decreased percentage of flap necrosis (p value = 0.0159) and increased cutaneous perfusion compared to the control group (p value = 0.0159). In addition, Spearman's rank correlation showed a significant negative correlation between percentage of flap necrosis and Laser Index (p value = 0.0083, r -0.83, respectively). Furthermore, significantly higher mean CD31 + vessel density was detected in the experimental group compared to the control group (p value = 0.0159). Additionally, semi-quantitative image analysis showed lower inflammatory cell count in experimental group compared to control group (p value = 0.0317). In vivo electroporation-mediated IL-10 gene transfer reduced necrosis, enhanced survival and vascularity in the ischemic skin flap.

  20. An Adjoint-Based Approach to Study a Flexible Flapping Wing in Pitching-Rolling Motion

    Science.gov (United States)

    Jia, Kun; Wei, Mingjun; Xu, Min; Li, Chengyu; Dong, Haibo

    2017-11-01

    Flapping-wing aerodynamics, with advantages in agility, efficiency, and hovering capability, has been the choice of many flyers in nature. However, the study of bio-inspired flapping-wing propulsion is often hindered by the problem's large control space with different wing kinematics and deformation. The adjoint-based approach reduces largely the computational cost to a feasible level by solving an inverse problem. Facing the complication from moving boundaries, non-cylindrical calculus provides an easy extension of traditional adjoint-based approach to handle the optimization involving moving boundaries. The improved adjoint method with non-cylindrical calculus for boundary treatment is first applied on a rigid pitching-rolling plate, then extended to a flexible one with active deformation to further increase its propulsion efficiency. The comparison of flow dynamics with the initial and optimal kinematics and deformation provides a unique opportunity to understand the flapping-wing mechanism. Supported by AFOSR and ARL.

  1. The effect of topical minoxidil pretreatment on nonsurgical delay of rat cutaneous flaps: further studies.

    Science.gov (United States)

    Gümüş, Nazım; Odemiş, Yusuf; Tuncer, Ersin; Yılmaz, Sarper

    2013-08-01

    The purpose of this study was to determine the effectiveness of topically applied minoxidil in the pharmacological delay phenomenon and to demonstrate the comparable microscopic and macroscopic changes between minoxidil-pretreated flaps and surgically delayed flaps. A modified version of the McFarlane flap was used. Group 1 rats, in which a caudally based dorsal skin flap was raised and sutured back, were the control group. In group II, minoxidil solution was spread over the marked skin flap area for 7 days. On the 7th day, a caudally based dorsal skin flap was elevated and then sutured back. Group III rats underwent a surgical delay procedure alone. On the 7th day after flap elevation, evaluation was done by histologic examination and calculation of the flap survival areas in all groups. The lowest flap survival rate appeared in group I and was statistically different from groups II and III. The mean surviving skin flap area in the minoxidil-pretreated group was significantly larger than that in the control group. After histologic evaluation, moderate angiogenesis was also detected in group II. We also found that surgical delay significantly reduced flap necrosis when compared to the minoxidil pretreatment group. According to our study, minoxidil may be considered an effective vasoactive agent for the stimulation of angiogenesis in rat cutaneous flaps and capable of achieving pharmacological delay and increasing flap survival. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  2. Use of Adipose-Derived Mesenchymal Stem Cells to Accelerate Neovascularization in Interpolation Flaps.

    Science.gov (United States)

    Izmirli, Hakki Hayrettin; Alagoz, Murat Sahin; Gercek, Huseyin; Eren, Guler Gamze; Yucel, Ergin; Subasi, Cansu; Isgoren, Serkan; Muezzinoglu, Bahar; Karaoz, Erdal

    2016-01-01

    Interpolation flaps are commonly used in plastic surgery to cover wide and deep defects. The need to, wait for 2 to 3 weeks until the division of the pedicle still, however, poses a serious challenge, not only extending treatment and hospital stay, but also increasing hospital expenses. To solve this problem, we have aimed to use the angiogenic potential of stem cells to selectively accelerate neovascularization with a view to increasing the viability of interpolation flaps and achieving early pedicle removal. A total of 32 rats were allocated to 2 groups as control (N = 16) and experiment (N = 16). The cranial flaps 6 × 5 cm in size located on the back of the rats were raised. Then, a total suspension containing 3 × 10(6) adipose-derived mesenchymal stem cells (ADSC) tagged with a green fluorescent protein (GFP) was injected diffusely into the distal part of the flap, receiving bed, and wound edges. In the control group, only a medium solution was injected into the same sites. After covering the 3 × 5 cm region in the proximal part of the area where the flap was removed, the distal part of the flap was adapted to the uncovered distal area. The pedicles of 4 rats in each group were divided on postoperative days 5, 8, 11, and 14. The areas were photographed 7 days after the pedicles were released. The photographs were processed using Adobe Acrobat 9 Pro software (San Jose, CA) to measure the flap survival area in millimeters and to compare groups. Seven days after the flap pedicle was divided, the rats were injected with 250 mCi Tc-99 mm (methoxy-isobutyl-isonitrie) from the penile vein, and scintigraphic images were obtained. The images obtained from each group were subjected to a numerical evaluation, which was then used in the comparison between groups. The flaps were then examined by histology to numerically compare the number of newly formed vessels. Neovascularization was also assessed by microangiography. In addition, radiographic images were obtained by

  3. Bilateral simultaneous breast reconstruction with SGAP flaps.

    Science.gov (United States)

    Flores, Jaime I; Magarakis, Michael; Venkat, Raghunandan; Shridharani, Sachin M; Rosson, Gedge D

    2012-07-01

    Two work-horse approaches to postmastectomy breast reconstruction are the deep inferior epigastric perforator flap and the superior gluteal artery perforator (SGAP) flap [and its variation, the lateral septocutaneous superior gluteal artery perforator flap]. Our purpose was fourfold: 1) to analyze our experience with the SGAP flaps for simultaneous bilateral breast reconstruction; 2) to analyze our experience with lateral septocutaneous superior gluteal artery perforator flaps for that procedure; 3) to compare our results with those in the literature; and 4) to highlight the importance of preoperative three-dimensional computed tomographic angiography. A retrospective chart review was completed for 23 patients who underwent breast reconstruction between December 2005 and January 2010 via an SGAP flap (46 flaps). We reviewed flap weight, ischemia time, length of stay, overall flap survival, fat necrosis development, and emergency re-exploration. Mean weights were 571.2 ± 222.0 g (range 186-1,117 g) and 568.0 ± 237.5 g (range 209-1,115 g) for the left and right buttock flap, respectively. Mean ischemia time was 129.1 ± 15.7 and 177.7 ± 24.7 minutes for the first and second flap, respectively. Mean hospital stay was 5.3 ± 2.5 days. All flaps survived. Fat necrosis developed in five flaps (10.8%), and emergency re-exploration was required in three patients (three flaps). When harvesting abdominal tissue is a poor option, the SGAP flap is an efficacious procedure for patients desiring autologous breast reconstruction, and bilateral procedures can be performed simultaneously. Copyright © 2012 Wiley Periodicals, Inc.

  4. [Aesthetic effect of wound repair with flaps].

    Science.gov (United States)

    Tan, Qian; Zhou, Hong-Reng; Wang, Shu-Qin; Zheng, Dong-Feng; Xu, Peng; Wu, Jie; Ge, Hua-Qiang; Lin, Yue; Yan, Xin

    2012-08-01

    To investigate the aesthetic effect of wound repair with flaps. One thousand nine hundred and ninety-six patients with 2082 wounds hospitalized from January 2004 to December 2011. These wounds included 503 deep burn wounds, 268 pressure sores, 392 soft tissue defects caused by trauma, 479 soft tissue defects due to resection of skin cancer and mole removal, 314 soft tissue defects caused by scar excision, and 126 other wounds. Wound area ranged from 1.5 cm x 1.0 cm to 30.0 cm x 22.0 cm. Sliding flaps, expanded flaps, pedicle flaps, and free flaps were used to repair the wounds in accordance with the principle and timing of wound repair with flaps. Five flaps showed venous congestion within 48 hours post-operation, 2 flaps of them improved after local massage. One flap survived after local heparin wet packing and venous bloodletting. One flap survived after emergency surgical embolectomy and bridging with saphenous vein graft. One flap showed partial necrosis and healed after skin grafting. The other flaps survived well. One thousand three hundred and twenty-one patients were followed up for 3 months to 2 years, and flaps of them were satisfactory in shape, color, and elasticity, similar to that of normal skin. Some patients underwent scar revision later with good results. Application of suitable flaps in wound repair will result in quick wound healing, good function recovery, and satisfactory aesthetic effect.

  5. Prevention of Oral Candidiasis After Free Flap Surgery: Role of 3% Sodium Bicarbonate Saline in Oral Care.

    Science.gov (United States)

    Yang, Yue; Zhang, Fang; Lyu, Xin; Yan, Zhimin; Hua, Hong; Peng, Xin

    2017-03-01

    Relevant reports about oral candidiasis status and prevention measures after free flap surgery for the oral and maxillofacial region are limited. The present study explored oral candidiasis status after free flap surgery and its prevention through a prospective comparative study. One hundred four patients were randomized to a control group (n = 54) and an experimental group (n = 50). Compared with the control group, the experimental group was provided an additional 3% sodium bicarbonate saline solution for oral care after free flap surgery. The incidence of oral candidiasis was evaluated by objective examination (saliva culture and salivary pH measurement) and subjective evaluation (clinical signs of oral candidiasis) at admission and from postoperative days 1 to 14. The salivary pH values of the 2 groups were lower than the normal salivary pH, and postoperative salivary pH values were always lower than the active range of oral lysozymes in the control group. The salivary pH values of the experimental group were higher than those of the control group from postoperative days 6 to 14 (P < .05). The incidence of oral candidiasis was 13.0% in the control group, which was higher than that in the experimental group (2.0%; P < .05). In addition, advanced age, use of a free flap for the simultaneous repair of intraoral and paraoral defects, and a combination of 2 antibiotic types were risk factors for oral candidiasis. Oral candidiasis was common in patients after free flap reconstruction surgery, and the use of 3% sodium bicarbonate saline solution for oral care effectively prevented it. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Pitch, roll, and yaw moment generator for insect-like tailless flapping-wing MAV

    Science.gov (United States)

    Phan, Hoang Vu; Park, Hoon Cheol

    2016-04-01

    In this work, we proposed a control moment generator, which is called Trailing Edge Change (TEC) mechanism, for attitudes change in hovering insect-like tailless flapping-wing MAV. The control moment generator was installed to the flapping-wing mechanism to manipulate the wing kinematics by adjusting the wing roots location symmetrically or asymmetrically. As a result, the mean aerodynamic force center of each wing is relocated and control moments are generated. The three-dimensional wing kinematics captured by three synchronized high-speed cameras showed that the flapping-wing MAV can properly modify the wing kinematics. In addition, a series of experiments were performed using a multi-axis load cell to evaluate the forces and moments generation. The measurement demonstrated that the TEC mechanism produced reasonable amounts of pitch, roll and yaw moments by shifting position of the trailing edges at the wing roots of the flapping-wing MAV.

  7. First-In-Flight Full-Scale Application of Active Flow Control: The XV-15 Tiltrotor Download Reduction

    National Research Council Canada - National Science Library

    Nagib, Hassan M; Kiedaisch, John W; Wygnanski, Israel J; Stalker, Aaron D; Wood, Tom; McVeigh, Michael A

    2004-01-01

    ... the effectiveness of Active flow Control (AFC) in reducing the download during hover. The flaps/ailerons were retrofitted with actuators delivering zero-mass-flux periodic jets emanating from slots positioned tangential to the surface...

  8. Distal scar-to-midline distance in pilonidal Limberg flap surgery is a recurrence-promoting factor: A multicenter, case-control study.

    Science.gov (United States)

    Kaplan, Mehmet; Ozcan, Onder; Bilgic, Ethem; Kaplan, Elif Tugce; Kaplan, Tugba; Kaplan, Fatma Cigdem

    2017-11-01

    The Limberg flap (LF) procedure is widely performed for the treatment of sacrococcygeal pilonidal sinus (SPS); however, recurrences continues to be observed. The aim of this study was to assess the relationship between LF designs and the risk of SPS recurrence. Sixty-one cases with recurrent disease (study group) and 194 controls, with a minimum of 5 recurrence-free years following surgery (control group), were included in the study. LF reconstructions performed in each group were classified as off-midline closure (OMC) and non-OMC types. Subsequently, the 2 groups were analyzed. After adjustment for all variables, non-OMC types showed the most prominent correlation with recurrence, followed by interrupted suturing type, family history of SPS, smoking, prolonged healing time, and younger age. The best cut-off value for the critical distance from the midline was found to be 11 mm (with 72% sensitivity and 95% specificity for recurrence). We recommend OMC modifications, with the flap tailored to create a safe margin of at least 2 cm between the flap borders and the midline. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Propeller TAP flap

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Bille, Camilla; Wamberg, Peter

    2013-01-01

    major complications needing additional surgery. One flap was lost due to a vascular problem. Breast reconstruction can be performed by a propeller TAP flap without cutting the descending branch of the thoracodorsal vessels. However, the authors would recommend that a small cuff of muscle is left around...

  10. Treatment of ischial pressure sores with both profunda femoris artery perforator flaps and muscle flaps.

    Science.gov (United States)

    Kim, Chae Min; Yun, In Sik; Lee, Dong Won; Lew, Dae Hyun; Rah, Dong Kyun; Lee, Won Jai

    2014-07-01

    Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. We retrospectively analyzed data from 14 patients (16 ischial sores) whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. All flaps survived the entire follow-up period. Seven patients (50%) had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years). The mean follow-up period was 27.9 months (range, 3-57 months). In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%), wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%), but resolved with conservative treatment. Among 16 cases, there was only one (6%) recurrence at 34 months. The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.

  11. Treatment of Ischial Pressure Sores with Both Profunda Femoris Artery Perforator Flaps and Muscle Flaps

    Directory of Open Access Journals (Sweden)

    Chae Min Kim

    2014-07-01

    Full Text Available Background Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. Methods We retrospectively analyzed data from 14 patients (16 ischial sores whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. Results All flaps survived the entire follow-up period. Seven patients (50% had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years. The mean follow-up period was 27.9 months (range, 3-57 months. In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%, wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%, but resolved with conservative treatment. Among 16 cases, there was only one (6% recurrence at 34 months. Conclusions The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.

  12. Electronic Cigarettes Are as Toxic to Skin Flap Survival as Tobacco Cigarettes.

    Science.gov (United States)

    Rau, Aline Sabrina; Reinikovaite, Viktorija; Schmidt, Eric P; Taraseviciene-Stewart, Laima; Deleyiannis, Frederic White-Brown

    2017-07-01

    Electronic cigarettes (e-cigarettes) have become increasingly popular. However, information about the health risks associated with e-cigarette use is sparse. Currently, no published studies examine the effects of chronic e-cigarette exposure on microcirculation or perfusion. Using a rat skin flap model, we examined the toxic microcirculatory effects e-cigarettes may have in comparison with tobacco cigarettes. Fifty-eight rats were randomized to either exposure to room air, tobacco cigarette smoke, medium-nicotine content (1.2%) e-cigarette vapor, or a high-nicotine content (2.4%) e-cigarette vapor. After 4 weeks of exposure, a random pattern, 3 × 9 cm skin flap was elevated on the dorsum of the rats. At 5 weeks, flap survival was evaluated quantitatively, and the rats were euthanized. Plasma was collected for nicotine and cotinine analysis, and flap tissues were harvested for histopathological analysis. Evaluation of the dorsal skin flaps demonstrated significantly increased necrosis in the vapor and tobacco groups. The average necrosis within the groups was as follows: control 19.23%, high-dose vapor 28.61%, medium-dose vapor 35.93%, and tobacco cigarette 30.15%. Although the e-cigarette and tobacco cigarette groups did not differ significantly, each individual group had significantly more necrosis than the control group (Pe-cigarette exposure groups had similar amounts of flap necrosis and hypoxia when compared with the tobacco cigarette exposure group. Nicotine-containing e-cigarette vapor is similarly toxic to skin flap survival as tobacco cigarettes.

  13. Modeling of Airfoil Trailing Edge Flap with Immersed Boundary Method

    DEFF Research Database (Denmark)

    Zhu, Wei Jun; Shen, Wen Zhong; Sørensen, Jens Nørkær

    2011-01-01

    The present work considers incompressible flow over a 2D airfoil with a deformable trailing edge. The aerodynamic characteristics of an airfoil with a trailing edge flap is numerically investigated using computational fluid dynamics. A novel hybrid immersed boundary (IB) technique is applied...... to simulate the moving part of the trailing edge. Over the main fixed part of the airfoil the Navier-Stokes (NS) equations are solved using a standard body-fitted finite volume technique whereas the moving trailing edge flap is simulated with the immersed boundary method on a curvilinear mesh. The obtained...... results show that the hybrid approach is an efficient and accurate method for solving turbulent flows past airfoils with a trailing edge flap and flow control using trailing edge flap is an efficient way to regulate the aerodynamic loading on airfoils....

  14. High-fidelity linear time-invariant model of a smart rotor with adaptive trailing edge flaps

    DEFF Research Database (Denmark)

    Bergami, Leonardo; Hansen, Morten Hartvig

    2017-01-01

    aero-servo-elastic model support the design, systematic tuning and model synthesis of smart rotor control systems. As an example application, the gains of an individual flap controller are tuned using the Ziegler-Nichols method for the full-order poles. The flap controller is based on feedback...

  15. Energy extraction from a semi-passive flapping-foil turbine with active heave and passive pitch

    Science.gov (United States)

    Boudreau, Matthieu; Dumas, Guy; Gunther, Kevin; CFD Laboratory LMFN Team

    2017-11-01

    Due to the inherent complexity of the mechanisms needed to prescribe the heaving and the pitching motions of optimal flapping-foil turbines, several research groups are now investigating the potential of using unconstrained passive motions. The amplitude, the phase and the frequency of such free motions are thus the result of the interaction of the blade with the flow and its elastic supports, namely springs and dampers. In parallel with our current study on fully-passive flapping-foil turbines, we investigate in this work the possibility of using a semi-passive turbine. Unlike previous semi-passive turbines studied in the literature, we propose a turbine with a passive pitching motion and an active heaving motion constrained to be a sine wave with desired amplitude and frequency. As most of the energy extracted by flapping-foil turbines comes from the heaving motion, it is natural to connect an electric generator to this degree of freedom, thereby allowing one to constrain this motion. It is found that large-amplitude pitching motions leading to a considerable energy extraction can arise under different circumstances and mechanisms, either forced by the heaving motion or driven by an instability of the pitching motion itself. The authors gratefully acknowledge the support from the Natural Sciences and Engineering Research Council of Canada (NSERC), the Tyler Lewis Clean Energy Research Foundation, Calcul Québec and Compute Canada.

  16. Free Boomerang-shaped Extended Rectus Abdominis Myocutaneous flap: The longest possible skin/myocutaneous free flap for soft tissue reconstruction of extremities.

    Science.gov (United States)

    Koul, Ashok R; Nahar, Sushil; Prabhu, Jagdish; Kale, Subhash M; Kumar, Praveen H P

    2011-09-01

    A soft tissue defect requiring flap cover which is longer than that provided by the conventional "long" free flaps like latissimus dorsi (LD) and anterolateral thigh (ALT) flap is a challenging problem. Often, in such a situation, a combination of flaps is required. Over the last 3 years, we have managed nine such defects successfully with a free "Boomerang-shaped" Extended Rectus Abdominis Myocutaneous (BERAM) flap. This flap is the slightly modified and "free" version of a similar flap described by Ian Taylor in 1983. This is a retrospective study of patients who underwent free BERAM flap reconstruction of soft tissue defects of extremity over the last 3 years. We also did a clinical study on 30 volunteers to compare the length of flap available using our design of BERAM flap with the maximum available flap length of LD and ALT flaps, using standard markings. Our clinical experience of nine cases combined with the results of our clinical study has confirmed that our design of BERAM flap consistently provides a flap length which is 32.6% longer than the standard LD flap and 42.2% longer than the standard ALT flap in adults. The difference is even more marked in children. The BERAM flap is consistently reliable as long as the distal end is not extended beyond the mid-axillary line. BERAM flap is simple in design, easy to harvest, reliable and provides the longest possible free skin/myocutaneous flap in the body. It is a useful new alternative for covering long soft tissue defects in the limbs.

  17. Aspects of the influence of an oscillating mini-flap upon the near wake of an airfoil NACA 4412

    Energy Technology Data Exchange (ETDEWEB)

    Delnero, J S; Di Leo, J Maranon; Colman, J; Garcia Sainz, M; Munoz, F; Herouard, N; Camocardi, M E, E-mail: delnero@ing.unlp.edu.ar [LaCLyFA, Departamento Aeronautica, Facultad de Ingenieria, Universidad Nacional de La Plata, calle 116 entre 47 y 48, CP 1900, La Plata (Argentina)

    2011-05-01

    A NACA 4412 airfoil was tested, in a boundary layer wind tunnel, with the aim to study the effect of a Gurney mini-flap, as an active and passive flow control device submitted to a turbulent flow field. The main objective was the experimental determination of flow pattern characteristics downstream the airfoil in the near wake. The untwisted wing model used for the experiments had 80 cm wingspan and 50 cm chord, with airfoil NACA 4412. The mini-flap was located on the lower surface at a distance, from the trailing edge, of 8%c (c airfoil chord). The Reynolds number, based upon the wing chord and the mean free stream velocity was 326,000 and 489,000. The turbulence intensity was 1.8%. The model was located into the wind tunnel between two panels, in order to assure a close approximation to two-dimensional flow over the model. As an active control device a rotating mini-flaps, geared by an electromechanical system (which rotate to a 30{sup 0}) was constructed. The wake pattern and pressure values near the trailing edge were measured. The results obtained, for this mechanism, show us that the oscillating mini-flap change the wake flow pattern, alleviating the near wake turbulence and enhancing the vortex pair near the trailing edge at the mini-flap level and below that level, magnifying the effect described first by Liebeck. That effect grows with the oscillating frequency. Additionally, the wake alleviation probably affects also the far wake. All of these facts suggest us to continue with the experiments, trying to measure the pressure distribution around the airfoil in all the cases, obtaining the lift and drag characteristics.

  18. Chimeric superficial temporal artery based skin and temporal fascia flap plus temporalis muscle flap - An alternative to free flap for suprastructure maxillectomy with external skin defect

    Directory of Open Access Journals (Sweden)

    Dushyant Jaiswal

    2011-01-01

    Full Text Available Flaps from temporal region have been used for mid face, orbital and peri-orbital reconstruction. The knowledge of the vascular anatomy of the region helps to dissect and harvest the muscle/fascia/skin/combined tissue flaps from that region depending upon the requirement. Suprastructure maxillectomy defects are usually covered with free flaps to fill the cavity. Here we report an innovative idea in which a patient with a supra structure maxillectomy with external skin defect was covered with chimeric flap based on the parietal and frontal branches of superficial temporal artery and the temporalis muscle flap based on deep temporal artery.

  19. Free Boomerang-shaped Extended Rectus Abdominis Myocutaneous flap: The longest possible skin/myocutaneous free flap for soft tissue reconstruction of extremities

    Directory of Open Access Journals (Sweden)

    Ashok R Koul

    2011-01-01

    Full Text Available Background: A soft tissue defect requiring flap cover which is longer than that provided by the conventional "long" free flaps like latissimus dorsi (LD and anterolateral thigh (ALT flap is a challenging problem. Often, in such a situation, a combination of flaps is required. Over the last 3 years, we have managed nine such defects successfully with a free "Boomerang-shaped" Extended Rectus Abdominis Myocutaneous (BERAM flap. This flap is the slightly modified and "free" version of a similar flap described by Ian Taylor in 1983. Materials and Methods: This is a retrospective study of patients who underwent free BERAM flap reconstruction of soft tissue defects of extremity over the last 3 years. We also did a clinical study on 30 volunteers to compare the length of flap available using our design of BERAM flap with the maximum available flap length of LD and ALT flaps, using standard markings. Results: Our clinical experience of nine cases combined with the results of our clinical study has confirmed that our design of BERAM flap consistently provides a flap length which is 32.6% longer than the standard LD flap and 42.2% longer than the standard ALT flap in adults. The difference is even more marked in children. The BERAM flap is consistently reliable as long as the distal end is not extended beyond the mid-axillary line. Conclusion: BERAM flap is simple in design, easy to harvest, reliable and provides the longest possible free skin/myocutaneous flap in the body. It is a useful new alternative for covering long soft tissue defects in the limbs.

  20. Effect of botulinum toxin A and nitroglycerin on random skin flap survival in rats.

    Science.gov (United States)

    Ghanbarzadeh, Kourosh; Tabatabaie, Omid Reza; Salehifar, Ebrahim; Amanlou, Massoud; Khorasani, Ghasemali

    2016-01-01

    A suitable pharmacological substitute for the well-established surgical delay technique for random skin flaps to increase viability has been elusive. To evaluate the effects of nitroglycerin and botulinum toxin type A on random flap survival in a rat model. The present controlled experimental study was performed in the four groups of rats. One week after intervention in each group, the flap was raised and kept in situ, and flap necrosis was evaluated through follow-up. Group 1 received intradermal botulinum toxin type A (BTX-A) and topical nitroglycerin 2%; group 2 received BTX-A and topical Vaseline (Unilever, USA); group 3 received topical nitroglycerin and intradermal normal saline; and group 4 received topical Vaseline and intradermal normal saline. BTX-A reduced the area of necrosis compared with control (24% versus 56% respectively; P<0.001). Nitroglycerin application was associated with a trend toward improved flap viability (42% versus 56%; P=0.059). The combination of topical nitroglycerin and BTX-A, compared with Vaseline and BTX-A, was associated with decreased flap necrosis (16.1% versus 24%, respectively), although it was not statistically significant (P=0.45). BTX-A was effective in reducing distal flap necrosis. The effect of BTX-A was significantly more pronounced than nitroglycerin ointment.

  1. Cost-effectiveness of monitoring free flaps.

    Science.gov (United States)

    Subramaniam, Shiva; Sharp, David; Jardim, Christopher; Batstone, Martin D

    2016-06-01

    Methods of free flap monitoring have become more sophisticated and expensive. This study aims to determine the cost of free flap monitoring and examine its cost effectiveness. We examined a group of patients who had had free flaps to the head and neck over a two-year period, and combined these results with costs obtained from business managers and staff. There were 132 free flaps with a success rate of 99%. The cost of monitoring was Aus $193/flap. Clinical monitoring during this time period cost Aus$25 476 and did not lead to the salvage of any free flaps. Cost equivalence is reached between monitoring and not monitoring only at a failure rate of 15.8%. This is to our knowledge the first study to calculate the cost of clinical monitoring of free flaps, and to examine its cost-effectiveness. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. All rights reserved.

  2. Smart helicopter rotors optimization and piezoelectric vibration control

    CERN Document Server

    Ganguli, Ranjan; Viswamurthy, Sathyamangalam Ramanarayanan

    2016-01-01

    Exploiting the properties of piezoelectric materials to minimize vibration in rotor-blade actuators, this book demonstrates the potential of smart helicopter rotors to achieve the smoothness of ride associated with jet-engined, fixed-wing aircraft. Vibration control is effected using the concepts of trailing-edge flaps and active-twist. The authors’ optimization-based approach shows the advantage of multiple trailing-edge flaps and algorithms for full-authority control of dual trailing-edge-flap actuators are presented. Hysteresis nonlinearity in piezoelectric stack actuators is highlighted and compensated by use of another algorithm. The idea of response surfaces provides for optimal placement of trailing-edge flaps. The concept of active twist involves the employment of piezoelectrically induced shear actuation in rotating beams. Shear is then demonstrated for a thin-walled aerofoil-section rotor blade under feedback-control vibration minimization. Active twist is shown to be significant in reducing vibra...

  3. Effect of topically applied minoxidil on the survival of rat dorsal skin flap.

    Science.gov (United States)

    Gümüş, Nazım; Odemiş, Yusuf; Yılmaz, Sarper; Tuncer, Ersin

    2012-12-01

    Flap necrosis still is a challenging problem in reconstructive surgery that results in irreversible tissue loss. This study evaluated the effect of topically applied minoxidil on angiogenesis and survival of a caudally based dorsal rat skin flap. For this study, 24 male Wistar rats were randomly divided into three groups of eight each. A caudally based dorsal skin flap with the dimensions of 9 × 3 cm was raised. After elevation of the flaps, they were sutured back into their initial positions. In group 1 (control group), 1 ml of isotonic saline was applied topically to the flaps of all the animals for 14 days. In group 2, minoxidil solution was spread uniformly over the flap surface for 7 days after the flap elevation. In group 3, minoxidil solution was applied topically to the flap surface during a 14-day period. On day 7 after the flap elevation, the rats were killed. The average area of flap survival was determined for each rat. Subdermal vascular architecture and angiogenesis were evaluated under a light microscope after two full-thickness skin biopsy specimens had been obtained from the midline of the flaps. The lowest flap survival rate was observed in group 1, and no difference was observed between groups 1 and 2. Compared with groups 1 and 2, group 3 had a significantly increased percentage of flap survival (P minoxidil is vasodilation and that prolonged use before flap elevation leads to angiogenesis, increasing flap viability. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. Effects of irradiation of skin flaps

    International Nuclear Information System (INIS)

    Sumi, Y.; Ueda, M.; Oka, T.; Torii, S.

    1984-01-01

    The reaction of skin flaps to irradiation and the optimum postoperative time for irradiation was studied in the rat. Flaps showed different reactions depending on the time of irradiation. There was a correlation between the radiosensitivity and the vascularity of the flap. Those flaps in the marginal hypovascular stage of revascularization showed reactions similar to normal skin. However, severe adverse reactions were observed in the marginal hypervascular stage

  5. Ornithopter Type Flapping Wings for Autonomous Micro Air Vehicles

    Directory of Open Access Journals (Sweden)

    Sutthiphong Srigrarom

    2015-05-01

    resonance phenomenon of a two-degree of freedom elastic system, that is, the wing is supported by the springs for flapping and feathering motions. Being oscillated close to the resonance frequency of the system, only by the torque in flapping motion, the amplitude gained is a few times higher than that of normal case. The first prototype was made from acrylic using a laser cutting machine. The wings were made up of carbon rods and kite material Ripstop. First test showed that the wings were too heavy for the mechanism to work. The third prototype was a smaller single gear crank design which was fabricated using a 3D printer. Initial test proved that the second prototype could withstand the high frequency flapping and near resonance amplitude as designed. With remote control, the third prototype was able to take off, climb, cruise and land in flapping mode successfully.

  6. Flap Lymphedema after Successful Reconstruction of the Chronic Inguinal Wound with a Vertical Rectus Abdominis Flap (VRAM

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2012-07-01

    Full Text Available The reconstruction of extensive and complex wounds represents a challenging problem for reconstructive surgeon. The reconstructive options to provide cover-age following debridment of these complicated wounds are local, distant flaps, or freetissue transfer. Vertical rectus abdominis flaps have been used succes-sully to repair defects in the groin, hip, perineal, trunk, and breast regions. We encountered flap lymphedema after successful reconstruction of the chronic in-guinal wound with a vertical rectus abdominis (VRAM flap. As far as were able to ascertain, there is no report in the literature related to flap lymphedema.

  7. Donor-site morbidity of the radial forearm free flap versus the ulnar forearm free flap.

    Science.gov (United States)

    Hekner, Dominique D; Abbink, Jan H; van Es, Robert J; Rosenberg, Antoine; Koole, Ronald; Van Cann, Ellen M

    2013-08-01

    Donor-site morbidity following harvest of the radial forearm free flap was compared with that following harvest of the ulnar forearm free flap. Twenty-eight radial forearm and 27 ulnar forearm flaps were harvested in 55 patients with head and neck defects. Pressure perception was measured with Semmes-Weinstein monofilaments. Cold perception was tested with chloroethyl. Donor-site healing was evaluated. Patients were interviewed about grip and pinch strength and donor-site appearance. In the radial forearm free flap group, pressure perception and cold perception were reduced in the donor hand, whereas in the ulnar group, no differences were observed between the donor and unoperated hands. In the radial forearm group, 15 percent of patients experienced reduced strength in the donor hand, whereas in the ulnar forearm group, none of the patients reported reduced strength in the donor hand. In the radial forearm group, 14 percent had partial or complete loss of the skin graft, whereas in the ulnar forearm group, 4 percent had partial loss of the skin graft. In the radial forearm group, 18 percent of patients were dissatisfied with the appearance of the donor site, and no complaints were reported in the ulnar forearm group. The authors' study shows less donor site-morbidity following harvest of the ulnar forearm free flap than following harvest of the radial forearm free flap. These results emphasize that the ulnar forearm free flap should be considered as an alternative for the radial forearm free flap for reconstruction of soft-tissue defects. Therapeutic, III.

  8. Development of a morphing flap using shape memory alloy actuators: the aerodynamic characteristics of a morphing flap

    International Nuclear Information System (INIS)

    Ko, Seung-Hee; Bae, Jae-Sung; Rho, Jin-Ho

    2014-01-01

    The discontinuous contour of a wing with conventional flaps diminishes the aerodynamic performance of an aircraft. A wing with a continuous contour does not experience extreme flow stream fluctuations during flight, and consequently has good aerodynamic characteristics. In this study, a morphing flap using shape memory alloy actuators is proposed, designed and fabricated, and its aerodynamic characteristics are investigated using aerodynamic analyses and wind tunnel tests. The ribs of the morphing flap are designed and fabricated with multiple elements joined together in a way that allows relative rotations of adjacent elements and forms a smooth contour of the morphing flap. The aerodynamic analyses of this multiple-element morphing-flap wing are performed using XFLR pro; its aerodynamic performance is compared with that of a mechanical-flap wing, and is measured through wind-tunnel tests. (papers)

  9. Hydrogen clearance: Assessment of technique for measurement of skin-flap blood flow in pigs

    International Nuclear Information System (INIS)

    Thomson, J.G.; Kerrigan, C.L.

    1991-01-01

    The hydrogen clearance technique has been used for many years by investigators to determine brain blood flow and has been partially validated in this setting using other methods of blood flow measurement. The method has been modified to allow blood flow measurements in skin, but the accuracy of H2 clearance for measuring skin blood flow has not been determined. Multiple blood flow measurements were performed using H2 clearance and radioactive microspheres on skin flaps and control skin in pigs. On 12 pigs, a total of 117 flap and 42 control skin measurements were available for analysis. There was no significant difference between the two techniques in measuring mean control skin blood flow. In skin flaps, H2 clearance was significantly correlated to microsphere-measured blood flow, but it consistently gave an overestimate. Sources of error may include injury to the tissues by insertion of electrodes, consumption of H2 by the electrodes, or diffusion of H2 from the relatively ischemic flap to its well-vascularized bed. Further studies are necessary to determine the cause of this error and to measure the technique's accuracy in skeletal muscle and other flaps

  10. Median forehead flap - beyond classic indication

    Directory of Open Access Journals (Sweden)

    Cristian R. Jecan

    2016-11-01

    Full Text Available Introduction. The paramedian forehead flap is one of the best options for reconstruction of the median upper two-thirds of the face due to its vascularity, color, texture match and ability to resurface all or part of the reconstructed area. The forehead flap is the gold standard for nasal soft tissue reconstruction and the flap of choice for larger cutaneous nasal defects having a robust pedicle and large amount of tissue. Materials and Methods. We are reporting a clinical series of cutaneous tumors involving the nose, medial canthus, upper and lower eyelid through a retrospective review of 6 patients who underwent surgical excision of the lesion and primary reconstruction using a paramedian forehead flap. Results. The forehead flap was used for total nose reconstruction, eyelids and medial canthal reconstruction. All flaps survived completely and no tumor recurrence was seen in any of the patients. Cosmetic and functional results were favorable. Conclusions. The forehead flap continues to be one of the best options for nose reconstruction and for closure of surgical defects of the nose larger than 2 cm. Even though is not a gold standard, median forehead flap can be an advantageous technique in periorbital defects reconstruction.

  11. Toward the bi-modal camber morphing of large aircraft wing flaps: the CleanSky experience

    Science.gov (United States)

    Pecora, R.; Amoroso, F.; Magnifico, M.

    2016-04-01

    The Green Regional Aircraft (GRA), one of the six CleanSky platforms, represents the largest European effort toward the greening of next generation air transportation through the implementation of advanced aircraft technologies. In this framework researches were carried out to develop an innovative wing flap enabling airfoil morphing according to two different modes depending on aircraft flight condition and flap setting: - Camber morphing mode. Morphing of the flap camber to enhance high-lift performances during take-off and landing (flap deployed); - Tab-like morphing mode. Upwards and downwards deflection of the flap tip during cruise (flap stowed) for load control at high speed and consequent optimization of aerodynamic efficiency. A true-scale flap segment of a reference aircraft (EASA CS25 category) was selected as investigation domain for the new architecture in order to duly face the challenges posed by real wing installation issues especially with reference to the tapered geometrical layout and 3D aerodynamic loads distributions. The investigation domain covered the flap region spanning 3.6 m from the wing kink and resulted characterized by a taper ratio equal to 0.75 with a root chord of 1.2 m. High TRL solutions for the adaptive structure, actuation and control system were duly analyzed and integrated while assuring overall device compliance with industrial standards and applicable airworthiness requirements.

  12. Hyperbaric oxygen therapy and surgical delay improve flap survival of reverse pedicle flaps for lower third leg and foot reconstruction

    Directory of Open Access Journals (Sweden)

    Pradeoth Mukundan Korambayil

    2015-06-01

    Full Text Available Aim: The purpose of the study is to present a management protocol for various types of soft tissue defects of the distal third region of leg and foot treated with pedicle flaps, by including hyperbaric oxygen (HBO therapy in the treatment regimen with flap delay. Methods: We present a prospective study of 23 patients with various types of soft tissue defects of the foot, and lower third of leg managed in our institution from December 2012 to December 2013. All soft tissue defects were treated by a reverse pedicle flap. Twelve patients were managed with flap delay with HBO therapy and 11 patients with immediate flaps without HBO therapy. The postoperative period, hospital course, and follow-up were documented. Results: Of 12 patients with flap delay and HBO, 10 patients did not suffer any complications secondary to flap transfer. One patient had discoloration of the tip of the flap, which settled without the intervention, and 1 patient had recurrent abscess formation, which required debridement and closure. Of 11 patients with direct transfer, 6 patients presented with complications including flap congestion, partial flap loss, and tip necrosis, which required secondary intervention. Conclusion: HBO therapy is a useful adjunct in flap delay of the reverse pedicle flap for soft tissue reconstruction of the lower third of the leg and foot regions.

  13. Effect of intradermal human recombinant copper-zinc superoxide dismutase on random pattern flaps in rats.

    Science.gov (United States)

    Schein, Ophir; Westreich, Melvyn; Shalom, Avshalom

    2013-09-01

    Studies have focused on enhancing flap viability using superoxide dismutase (SOD), but only a few used SOD from human origin, and most gave the compound systemically. We evaluated the ability of SOD to improve random skin flap survival using human recombinant copper-zinc superoxide dismutase (Hr-CuZnSOD) in variable doses, injected intradermally into the flap. Seventy male Sprague Dawley rats were randomly assigned into 4 groups. Cephalic random pattern flaps were elevated on their backs and intradermal injections of different dosages of Hr-CuZnSOD were given 15 minutes before surgery. Flap survival was evaluated by fluorescein fluorescence. Analysis of variance (ANOVA) and t test statistical analyses were performed. Flap survival in all treated groups was significantly better than in the controls. The beneficial effect of HR-CuZnSOD on flap survival is attained when it is given intradermally into the flap tissue. Theoretically, Hr-CuZnSOD delivered with local anesthetics used in flap elevation may be a valuable clinical tool. Copyright © 2012 Wiley Periodicals, Inc.

  14. The Temporalis Muscle Flap in Maxillofacial Reconstruction

    International Nuclear Information System (INIS)

    ElSheikh, M; Zeitoun, I; ElMassry, M A K

    1991-01-01

    The temporalis muscle flap is a very versatile and valuable axial flap, which could be used in various reconstructive procedures in and around the oro-maxillofacial region. The surgical anatomy, vascular pattern and technique of elevation of the flap are described, together with our experience in different reconstructive situations. The advantages and disadvantages of the use of this flap are thoroughly discussed taking into consideration the potentiality of cancer recurrence under cover of the flap. (author)

  15. Control-oriented reduced order modeling of dipteran flapping flight

    Science.gov (United States)

    Faruque, Imraan

    Flying insects achieve flight stabilization and control in a manner that requires only small, specialized neural structures to perform the essential components of sensing and feedback, achieving unparalleled levels of robust aerobatic flight on limited computational resources. An engineering mechanism to replicate these control strategies could provide a dramatic increase in the mobility of small scale aerial robotics, but a formal investigation has not yet yielded tools that both quantitatively and intuitively explain flapping wing flight as an "input-output" relationship. This work uses experimental and simulated measurements of insect flight to create reduced order flight dynamics models. The framework presented here creates models that are relevant for the study of control properties. The work begins with automated measurement of insect wing motions in free flight, which are then used to calculate flight forces via an empirically-derived aerodynamics model. When paired with rigid body dynamics and experimentally measured state feedback, both the bare airframe and closed loop systems may be analyzed using frequency domain system identification. Flight dynamics models describing maneuvering about hover and cruise conditions are presented for example fruit flies (Drosophila melanogaster) and blowflies (Calliphorids). The results show that biologically measured feedback paths are appropriate for flight stabilization and sexual dimorphism is only a minor factor in flight dynamics. A method of ranking kinematic control inputs to maximize maneuverability is also presented, showing that the volume of reachable configurations in state space can be dramatically increased due to appropriate choice of kinematic inputs.

  16. Tensor fascia lata flap versus tensor fascia lata perforator-based island flap for the coverage of extensive trochanteric pressure sores.

    Science.gov (United States)

    Kim, Youn Hwan; Kim, Sang Wha; Kim, Jeong Tae; Kim, Chang Yeon

    2013-06-01

    Tensor fascia lata (TFL) musculocutaneous flaps often require a donor site graft when harvesting a large flap. However, a major drawback is that it also sacrifices the muscle. To overcome this disadvantage, we designed a TFL perforator-based island flap that was harvested from a site near the defect and involved transposition within 90 degrees without full isolation of the pedicles. We performed procedures on 17 musculocutaneous flaps and 23 perforator-based island flaps, and compared the outcomes of these surgeries. The overall complication rate was 27.5% (11 regions). There were 7 complications related to the musculocutaneous flaps and 4 complications related to the perforator flaps. Although there were no statistical differences between those groups, lower complication rates were associated with procedures involving perforator flaps. The TFL perforator procedure is a simple and fast operation that avoids sacrificing muscle. This decreases complication rates compared to true perforator flap techniques that require dissection around the perforator or pedicle.

  17. Tubularized Penile-Flap Urethroplasty Using a Fasciocutaneous Random Pedicled Flap for Recurrent Anterior Urethral Stricture

    Directory of Open Access Journals (Sweden)

    Yong Jig Lee

    2012-05-01

    Full Text Available This report describes the use of a tubularized random flap for the curative treatment of recurrent anterior urethral stricture. Under the condition of pendulous lithotomy and suprapubic cystostomy, the urethral stricture was removed via a midline ventral penile incision followed by elevation of the flap and insertion of an 18-Fr catheter. Subcutaneous buried interrupted sutures were used to reapproximate the waterproof tubularized neourethra and to coapt with the neourethra and each stump of the urethra, first proximally and then distally. The defect of the penile shaft was covered by advancement of the surrounding scrotal flap. The indwelling catheter was maintained for 21 days. A 9 month postoperative cystoscopy showed no flap necrosis, no mechanical stricture, and no hair growth on the lumen of the neourethra. The patient showed no voiding discomfort 6 months after the operation. The advantages of this procedure are the lack of need for microsurgery, shortening of admission, the use of only spinal anesthesia (no general anesthesia, and a relatively short operative time. The tubularized unilateral penile fasciocutaneous flap should be considered an option for initial flap urethroplasty as a curative technique.

  18. Reconstruction of the Lower Extremity Using Free Flaps

    Directory of Open Access Journals (Sweden)

    Min Jo Kang

    2013-09-01

    Full Text Available Background The aim of lower-extremity reconstruction has focused on wound coverage andfunctional recovery. However, there are limitations in the use of a local flap in cases of extensivedefects of the lower-extremities. Therefore, free flap is a useful option in lower-extremityreconstruction.Methods We performed a retrospective review of 49 patients (52 cases who underwentlower-extremity reconstruction at our institution during a 10-year period. In these patients,we evaluated causes and sites of defects, types of flaps, recipient vessels, types of anastomosis,survival rate, and complications.Results There were 42 men and 10 women with a mean age of 32.7 years (range, 3-72years. The sites of defects included the dorsum of the foot (19, pretibial area (17, ankle(7, heel (5 and other sites (4. The types of free flap included latissimus dorsi muscle flap(10, scapular fascial flap (6, anterolateral thigh flap (6, and other flaps (30. There werefour cases of vascular complications, out of which two flaps survived after intervention. Theoverall survival of the flaps was 96.2% (50/52. There were 19 cases of other complications atrecipient sites such as partial graft loss (8, partial flap necrosis (6 and infection (5. However,these complications were not notable and were resolved with skin grafts.Conclusions The free flap is an effective method of lower-extremity reconstruction. Goodoutcomes can be achieved with complete debridement and the selection of appropriaterecipient vessels and flaps according to the recipient site.

  19. Free flap reconstruction for diabetic foot limb salvage.

    Science.gov (United States)

    Sato, Tomoya; Yana, Yuichiro; Ichioka, Shigeru

    2017-12-01

    Although free flap is gaining popularity for the reconstruction of diabetic foot ulcers, it is unclear whether free flap reconstruction increases the chances of postoperative independent ambulation. The aim of this study is to evaluate the relationship between free flap success and postoperative ambulation. This study reviewed 23 cases of free flap reconstruction for diabetic foot ulcers between January 2007 and March 2014. Free rectus abdominis, latissimus dorsi, and anterolateral thigh flaps were used in ten, eight, and five patients, respectively. A comparison was made between free flap success and postoperative independent ambulation using Fisher's exact test. Two patients developed congestive heart failure with fatal consequences within 14 days postoperatively, resulting in an in-hospital mortality rate of 8.7%. Five patients lost their flaps (21.7%). Of the 16 patients who had flap success, 12 achieved independent ambulation. Five patients with flap loss did not achieve independent ambulation, except one patient who underwent secondary flap reconstruction using a distally based sural flap. Fisher's exact test revealed that independent ambulation was associated with free flap success (p = 0.047). The present study indicates that free flap reconstruction may increase the possibility of independent ambulation for patients with extensive tissue defects due to diabetic ulcers. Intermediate limb salvage rates and independent ambulation rates were favourable in patients with successful reconstruction. The use of foot orthoses and a team approach with pedorthists were effective to prevent recurrence.

  20. Use if a soecuak sokubt ub reverse syrak artery flap to reduce venous congestion and flap necrosis

    International Nuclear Information System (INIS)

    Masood, T.; Ahmed, R.; Obaidullah, M.

    2016-01-01

    Background: Distally based sural fascio-cutaneous flap is a commonly performed plastic surgery procedure for the coverage of distal third of leg, ankle and foot defects. However congestion is the main complication of this flap which results into partial or complete loss of the flap. We devised a special splint to reduce this complication and retrospectively reviewed its effect on this complication between two groups. Methods: This retrospective study was carried out at Northwest General hospital between 1995 and 2012. Group-A included 30 patients who were managed without the splint between 1995 and 2005 and group B comprised of 35 patients were treated with the splint between 2006 and 2012. Complications like venous congestion, epidermolysis, and partial and complete flap failure were documented. Data were analyzed by SPSS.16.5 software. Chi- square test was used for data analysis. P value less than 0.05 was considered as the level of significance. Results: Total 65 patients were operated. Age of the patients ranged from 7 to 60 years. Road traffic accident and spoke wheel injury was the main cause of soft tissue loss in our patients. In group A 12 patients suffered from venous congestion. Out of 12, three patients had epidermolysis while partial flap necrosis occurred in 9 patients. Only 3 patients had venous congestion in group B. Two patients suffered from epidermolysis and one had partial flap necrosis. None of patient suffered from complete flap loss in both groups. Conclusion: Reverse sural artery flap continues to be a versatile flap for distal lower extremity reconstruction. By using a special splint to reduce pressure on the pedicle site as a modification, flap complication rate can be decreased significantly. (author)

  1. Use of the Anterolateral Thigh and Vertical Rectus Abdominis Musculocutaneous Flaps as Utility Flaps in Reconstructing Large Groin Defects

    Directory of Open Access Journals (Sweden)

    Edwin Jonathan Aslim

    2014-09-01

    Full Text Available BackgroundGroin dissections result in large wounds with exposed femoral vessels requiring soft tissue coverage, and the reconstructive options are diverse. In this study we reviewed our experience with the use of the pedicled anterolateral thigh and vertical rectus abdominis musculocutaneous flaps in the reconstruction of large groin wounds.MethodsGroin reconstructions performed over a period of 10 years were evaluated, with a mean follow up of two years. We included all cases with large or complex (involving perineum defects, which were reconstructed with the pedicled anterolateral thigh musculocutaneous or the vertical rectus abdominis musculocutaneous (VRAM flaps. Smaller wounds which were covered with skin grafts, locally based flaps and pedicled muscle flaps were excluded.ResultsTwenty-three reconstructions were performed for large or complex groin defects, utilising the anterolateral thigh (n=10 and the vertical rectus abdominis (n=13 pedicled musculocutaneous flaps. Femoral vein reconstruction with a prosthetic graft was required in one patient, and a combination flap (VRAM and gracilis muscle flap was performed in another. Satisfactory coverage was achieved in all cases without major complications. No free flaps were used in our series.ConclusionsThe anterolateral thigh and vertical rectus abdominis pedicled musculocutaneous flaps yielded consistent results with little morbidity in the reconstruction of large and complex groin defects. A combination of flaps can be used in cases requiring extensive cover.

  2. Energy management - The delayed flap approach

    Science.gov (United States)

    Bull, J. S.

    1976-01-01

    Flight test evaluation of a Delayed Flap approach procedure intended to provide reductions in noise and fuel consumption is underway using the NASA CV-990 test aircraft. Approach is initiated at a high airspeed (240 kt) and in a drag configuration that allows for low thrust. The aircraft is flown along the conventional ILS glide slope. A Fast/Slow message display signals the pilot when to extend approach flaps, landing gear, and land flaps. Implementation of the procedure in commercial service may require the addition of a DME navigation aid co-located with the ILS glide slope transmitter. The Delayed Flap approach saves 250 lb of fuel over the Reduced Flap approach, with a 95 EPNdB noise contour only 43% as large.

  3. Reconstruction of the Lower Extremity Using Free Flaps

    Directory of Open Access Journals (Sweden)

    Min Jo Kang

    2013-09-01

    Full Text Available BackgroundThe aim of lower-extremity reconstruction has focused on wound coverage and functional recovery. However, there are limitations in the use of a local flap in cases of extensive defects of the lower-extremities. Therefore, free flap is a useful option in lower-extremity reconstruction.MethodsWe performed a retrospective review of 49 patients (52 cases who underwent lower-extremity reconstruction at our institution during a 10-year period. In these patients, we evaluated causes and sites of defects, types of flaps, recipient vessels, types of anastomosis, survival rate, and complications.ResultsThere were 42 men and 10 women with a mean age of 32.7 years (range, 3-72 years. The sites of defects included the dorsum of the foot (19, pretibial area (17, ankle (7, heel (5 and other sites (4. The types of free flap included latissimus dorsi muscle flap (10, scapular fascial flap (6, anterolateral thigh flap (6, and other flaps (30. There were four cases of vascular complications, out of which two flaps survived after intervention. The overall survival of the flaps was 96.2% (50/52. There were 19 cases of other complications at recipient sites such as partial graft loss (8, partial flap necrosis (6 and infection (5. However, these complications were not notable and were resolved with skin grafts.ConclusionsThe free flap is an effective method of lower-extremity reconstruction. Good outcomes can be achieved with complete debridement and the selection of appropriate recipient vessels and flaps according to the recipient site.

  4. [COMPARISON OF REPAIR EFFECT BETWEEN CHIMERIC ANTEROLATERAL THIGH FLAP AND SERIES-WOUND FLAPS FOR DEFECT AFTER RESECTION OF ORAL AND MAXILLOFACIAL CANCER].

    Science.gov (United States)

    Yang, Heping; Zhang, Hongwu; Chen, Haidi; Yang, Shuxiong; Wang, Jun; Hu, Dawang

    2016-04-01

    To compare the effectiveness of complex defects repair between using chimeric anterolateral thigh flap and series-wound flaps after resection of oral and maxillofacial cancer. After resection of oral and maxillofacial cancer, defect was repaired with chimeric anterolateral thigh flap in 39 patients between January 2011 and July 2014 (chimeric anterolateral thigh flap group); and defect was repaired with series-wound flaps in 35 patients between January 2009 and December 2010 (series-wound flaps group). There was no significant difference in gender, age, duration of disease, tumor type, tumor staging, defect location, and defect area between 2 groups (P > 0.05). The operation time, flap harvesting and microvascular anastomosis time, stomach tube extraction time, and oral feeding time were recorded and compared between 2 groups, and postoperative complications were observed; the effectiveness was evaluated according to clinical efficacy evaluation table of bone and soft tissue defects reconstruction surgery in oral and maxillofacial region. Vascular crisis occurred in 2 cases of chimeric anterolateral thigh flap group, and 4 cases of series-wound flaps group. Partial necrosis appeared at distal end of a series-wound flaps, and oral fistula and infection developed in 3 series-wound flaps. The other flaps and the grafted skin at donor site survived; wounds at recipient site healed by first intention. The operation time, stomach tube extraction time, and oral feeding time of chimeric anterolateral thigh flap group were significantly shorter than those of series-wound flaps group (P oral closure function, chew, language performance, and swallowing scores of the chimeric anterolateral thigh-flap group were significantly better than those of the series-wound flaps group (P oral cavity holding water test, and occlusion scores between the 2 groups (P > 0.05). Using chimeric anterolateral thigh flap for defect repair after resection of oral and maxillofacial cancer can

  5. Innervated boomerang flap for finger pulp reconstruction.

    Science.gov (United States)

    Chen, Shao-Liang; Chiou, Tai-Fung

    2007-11-01

    The boomerang flap originates from the dorsolateral aspect of the proximal phalanx of an adjacent digit and is supplied by the retrograde blood flow through the vascular arcades between the dorsal and palmar digital arteries. To provide sensation of the boomerang flap for finger pulp reconstruction, the dorsal sensory branch of the proper digital nerve and the superficial sensory branch of the corresponding radial or ulnar nerve are included within the skin flap. After transfer of the flap to the injured site, epineural neurorrhaphies are done between the digital nerves of the pulp and the sensory branches of the flap. We used this sensory flap in five patients, with more than 1 year follow-up, and all patients achieved measurable two-points discrimination. The boomerang flap not only preserves the proper palmar digital artery but also provides an extended and innervated skin paddle. It seems to be an alternative choice for one-stage reconstruction of major pulp defect.

  6. Reconstruction of Facial Defect Using Deltopectoral Flap.

    Science.gov (United States)

    Aldelaimi, Tahrir N; Khalil, Afrah A

    2015-11-01

    Reconstruction of the head and neck is a challenge for otolarygology surgeons, maxillofacial surgeons as well as plastic surgeons. Defects caused by the resection and/or trauma should be closed with flaps which match in color, texture and hair bearing characteristics with the face. Deltopectoral flap is a one such flap from chest and neck skin mainly used to cover the facial defects. This study report a patient presenting with tragic Road Traffic Accident (RTA) admitted to maxillofacial surgery department at Ramadi Teaching Hospital, Anbar province, Iraq. An incision, medially based, was done and deltopectoral fascio-cutaneous flap was used for surgical exposure and closure of defects after RTA. There was no major complication. Good aesthetic and functional results were achieved. Deltopectoral flap is an excellent alternative for the reconstruction of head and neck. Harvesting and application of the flap is rapid and safe. Only a single incision is sufficient for dissection and flap elevation.

  7. Aerothermal Assment Of The Expert Flap In The SCIROCCO Wind Tunnel

    Science.gov (United States)

    Walpot, L.; Di Clemente, M.; Vos, J.; Etchells, J.; Trifoni, E.; Thoemel, J.; Gavira, J.

    2011-05-01

    In the frame of the “In-Flight Test Measurement Techniques for Aerothermodynamics” activity of the EXPERT Program, the EXPERT Instrumented Open Flap Assembly experiment has the objective to verify the design/sensor integration and validate the CFD tools. Ground based measurements were made in Europe’s largest high enthalpy plasma facility, Scirocco in Italy. Two EXPERT flaps of the flight article, instrumented with 14 thermocouples, 5 pressure ports, a pyrometer and an IR camera mounted in the cavity instrumented flap will collect in-flight data. During the Scirocco experiment, an EXPERT flap model identical to the flight article was mounted at 45 deg on a holder including cavity and was subjected to a hot plasma flow at an enthalpy up to 11MJ/kg at a stagnation pressure of 7 bar. The test model sports the same pressure sensors as the flight article. Hypersonic state-of-the-art codes were then be used to perform code-to-code and wind tunnel-to-code comparisons, including thermal response of the flap as collected during the tests by the sensors and camera.

  8. Spectral analysis of blood perfusion in the free latissimus dorsi myocutaneous flap and in normal skin

    International Nuclear Information System (INIS)

    Liu Xudong; Zeng Bingfang; Fan Cunyi; Jiang Peizhu; Hu Xiao

    2006-01-01

    To find the properties in the oscillatory components of the cutaneous blood flow on the successful free flap, a wavelet transform was applied to the laser Doppler flowmetry (LDF) signals which were measured simultaneously on the surfaces of the free latissimus dorsi myocutaneous flap and on the adjacent intact skin of the healthy limb, of 18 patients. The frequency interval from 0.0095 to 1.6 Hz was examined and was divided into five subintervals (I: 0.0095-0.021 Hz; II: 0.021-0.052 Hz; III: 0.052-0.145 Hz; IV: 0.145-0.6 Hz and V: 0.6-1.6 Hz) corresponding to endothelial metabolic, neurogenic, myogenic, respiratory and cardiac origins. The average amplitude and total power in the frequency range 0.0095-1.6 Hz as well as within subintervals I, II, IV and V were significantly lower for signals measured on the free flap than those obtained in the healthy limb. However in interval III, they were significantly higher. The normalized spectral amplitude and power in the free flap were significantly lower in only two intervals, I and II, yet in interval III they were significantly higher; no statistical significance was observed in intervals IV and V. The distinctive finding made in this study, aside from the decrease of endothelial metabolic processes and sympathetic control, was the significant increase of myogenic activity in the free flap. It is hoped that this work will contribute towards knowledge on blood circulation in free flaps and make the monitoring by LDF more reliable

  9. Refining the intrinsic chimera flap: a review.

    Science.gov (United States)

    Agarwal, Jayant P; Agarwal, Shailesh; Adler, Neta; Gottlieb, Lawrence J

    2009-10-01

    Reconstruction of complex tissue deficiencies in which each missing component is in a different spatial relationship to each other can be particularly challenging, especially in patients with limited recipient vessels. The chimera flap design is uniquely suited to reconstruct these deformities. Chimera flaps have been previously defined in many ways with 2 main categories: prefabricated or intrinsic. Herein we attempt to clarify the definition of a true intrinsic chimeric flap and provide examples of how these constructs provide a method for reconstruction of complex defects. The versatility of the intrinsic chimera flap and its procurement from 7 different vascular systems is described. A clarification of the definition of a true intrinsic chimera flap is described. In addition, construction of flaps from the lateral femoral circumflex, deep circumflex iliac, inferior gluteal, peroneal, subscapular, thoracodorsal, and radial arterial systems is described to showcase the versatility of these chimera flaps. A true intrinsic chimera flap must consist of more than a single tissue type. Each of the tissue components receives its blood flow from separate vascular branches or perforators that are connected to a single vascular source. These vascular branches must be of appropriate length to allow for insetting with 3-dimensional spatial freedom. There are a multitude of sites from which true intrinsic chimera flaps may be harvested.

  10. The role of postoperative hematoma on free flap compromise.

    Science.gov (United States)

    Ahmad, Faisal I; Gerecci, Deniz; Gonzalez, Javier D; Peck, Jessica J; Wax, Mark K

    2015-08-01

    Hematomas may develop in the postoperative setting after free tissue transfer. When hematomas occur, they can exert pressure on surrounding tissues. Their effect on the vascular pedicle of a free flap is unknown. We describe our incidence of hematoma in free flaps and outcomes when the flap is compromised. Retrospective chart review of 1,883 free flaps performed between July 1998 and June 2014 at a tertiary referral center. Patients with free flap compromise due to hematoma were identified. Etiology, demographic data, and outcomes were evaluated. Eighty-eight (4.7%) patients developed hematomas. Twenty (22.7%) of those had flap compromise. Twelve compromises (60%) showed evidence of pedicle thrombosis. The salvage rate was 75% versus 54% in 79 flaps with compromise from other causes (P = .12). Mean time to detection of the hematoma was 35.3 hours in salvaged flaps compared to 91.6 hours in unsalvageable flaps (P = .057). Time to operating room (OR) from detection was 2.8 hours in salvageable flaps compared to 12.4 hours in nonsalvageable flaps (P = .053). The salvage rate for flaps that returned to the OR in hematomas developed rarely. When they did, 23% went on to develop flap compromise. Prompt recognition and re-exploration allowed for a high salvage rate. Vessel thrombosis predicted inability to salvage the flap. 4 © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  11. An innovative method of planning and displaying flap volume in DIEP flap breast reconstructions

    NARCIS (Netherlands)

    Hummelink, S.L.; Verhulst, A.C.; Maal, T.J.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Ulrich, D.J.O.

    2017-01-01

    BACKGROUND: Determining the ideal volume of the harvested flap to achieve symmetry in deep inferior epigastric artery perforator (DIEP) flap breast reconstructions is complex. With preoperative imaging techniques such as 3D stereophotogrammetry and computed tomography angiography (CTA) available

  12. Morbidity and cost differences between free flap reconstruction and pedicled flap reconstruction in oral and oropharyngeal cancer: Matched control study

    NARCIS (Netherlands)

    Smeele, Ludwig E.; Goldstein, David; Tsai, Vance; Gullane, Patrick J.; Neligan, Peter; Brown, Dale H.; Irish, Jonathan C.

    2006-01-01

    To compare morbidity and cost in patients who underwent primary reconstruction with free tissue transfer with those with pectoralis major myocutaneous flap (PMMF) reconstructions after ablation of oral and oropharyngeal squamous cell carcinoma. Over a 6-year period, 36 patients had PMMF

  13. PIV study of flow around unsteady airfoil with dynamic trailing-edge flap deflection

    Energy Technology Data Exchange (ETDEWEB)

    Gerontakos, P.; Lee, T. [McGill University, Department of Mechanical Engineering, Montreal, Quebec (Canada)

    2008-12-15

    The flow around an oscillating NACA 0015 airfoil with prescheduled trailing-edge flap motion control was investigated by using particle image velocimetry (PIV). Aerodynamic load coefficients, obtained via surface pressure measurements, were also acquired to supplement the PIV results. The results demonstrate that upward flap deflections led to an improved negative peak pitching moment coefficient C{sub m,peak}, mainly as a consequence of the increased suction pressure on the lower surface of the flap. The behavior of the leading-edge vortex (LEV) was largely unaffected. Its strength was, however, reduced slightly compared to that of the uncontrolled airfoil. No trailing-edge vortex was observed. For downward flap deflection, the strength of the LEV was found to be slightly increased. A favorable increase in C{sub l,max}, as a consequence of downward flap-induced positive camber effects, accompanied by a detrimental increase in the nose-down C{sub m,peak}, due to the large pressure increase on the lower surface of the flap, was also observed. (orig.)

  14. Retention of a reconstructed nipple using a C-V flap with different layer thicknesses in the C-flap.

    Science.gov (United States)

    Sowa, Yoshihiro; Itsukage, Sizu; Sakaguchi, Kouichi; Taguchi, Tetsuya; Numajiri, Toshiaki

    2018-04-01

    The C-V flap for nipple reconstruction is now one of standard surgical techniques. But decreased projection is still a problem. In recent years, it has been suggested that projection can be more easily maintained when raising of the C-flap is performed with a split thickness dermis. In this study, we examined whether decrease of projection can be prevented by raising of a C-flap with a split dermis rather than with full dermis. A total of 49 consecutive patients who underwent reconstruction of a nipple using the C-V flap technique were enrolled. The patients included 22 who underwent surgery using a C-flap with a full thickness dermis (Group F), and 27 who underwent surgery with raising of a flap with a split thickness dermis (Group S). The size of the reconstructed nipple was measured at 2 weeks, 6 months and 1 year postoperatively for comparison between Groups F and S. Partial necrosis of the C-flap end occurred in 4 subjects in only Group S. The decrease in projection after 1 year postoperatively in Group S was significantly lower than that in Group F. In contrast, the teat base size in Group F tended to be greater than that in Group S, suggesting a tendency for an expanded base using a flap with a full dermis. Our results indicated that it is recommended to use a C-flap with a split dermis for cases with high projection of the nipple on the contralateral side.

  15. Micro Aerial Vehicle (MAV Flapping Motion Control Using an Immune Network with Different Immune Factors

    Directory of Open Access Journals (Sweden)

    Liguo Weng

    2013-08-01

    Full Text Available This paper proposes a novel Neural-Immunology/Memory Network to address the problem of motion control for flapping-wing Micro Aerial Vehicles (MAVs. This network is inspired by the human memory system as well as the immune system, and it is effective in attenuating the system errors and other lumped system uncertainties. In contrast to most existing Neural Networks, the convergence of this proposed Neural-Immunology/Memory Network can be theoretically proven. Both analyses and simulations that are based on different immune factors show that the proposed control method is effective in dealing with external disturbances, system nonlinearities, uncertainties and parameter variations.

  16. Parasacral Perforator Flaps for Reconstruction of Sacral Pressure Sores.

    Science.gov (United States)

    Lin, Chin-Ta; Chen, Shih-Yi; Chen, Shyi-Gen; Tzeng, Yuan-Sheng; Chang, Shun-Cheng

    2015-07-01

    Despite advances in reconstruction techniques, pressure sores continue to present a challenge to the plastic surgeon. The parasacral perforator flap is a reliable flap that preserves the entire contralateral side as a future donor site. On the ipsilateral side, the gluteal muscle itself is preserved and all flaps based on the inferior gluteal artery are still possible. We present our experience of using parasacral perforator flaps in reconstructing sacral defects. Between August 2004 and January 2013, 19 patients with sacral defects were included in this study. All the patients had undergone surgical reconstruction of sacral defects with a parasacral perforator flap. The patients' sex, age, cause of sacral defect, flap size, flap type, numbers of perforators used, rotation angle, postoperative complications, and hospital stay were recorded. There were 19 parasacral perforator flaps in this series. All flaps survived uneventfully except for 1 parasacral perforator flap, which failed because of methicillin-resistant Staphylococcus aureus infection. The overall flap survival rate was 95% (18/19). The mean follow-up period was 17.3 months (range, 2-24 months). The average length of hospital stay was 20.7 days (range, 9-48 days). No flap surgery-related mortality was found. Also, there was no recurrence of sacral pressure sores or infected pilonidal cysts during the follow-up period. Perforator-based flaps have become popular in modern reconstructive surgery because of low donor-site morbidity and good preservation of muscle. Parasacral perforator flaps are durable and reliable in reconstructing sacral defects. We recommend the parasacral perforator flap as a good choice for reconstructing sacral defects.

  17. Gust alleviation for a STOL transport by using elevator, spoilers, and flaps

    Science.gov (United States)

    Lallman, F. J.

    1974-01-01

    Control laws were developed to investigate methods of alleviating the response of a STOL transport to gusty air. The transport considered in the study had triple-slotted, externally blown jet flaps and a large T-tail. The control devices used were the elevator, spoilers, and flaps. A hybrid computing system was used to simulate linearized longitudinal dynamics of the aircraft and to implement a conjugate gradient optimal search algorithm. The aircraft was simulated in the low-speed approach condition only. Feedback control matrices were found which minimized the average of a quadratic functional involving passenger compartment accelerations, pitch angle and rate, flight path angle and speed variations. The optimization was performed for artificially designed gust inputs in the form of predetermined rectangular waveforms. Results were obtained for elevator, spoilers, and flaps acting singly and in combination. Additional results were obtained for unit sinusoidal gust inputs by using the gain matrices computed for the artificial test gusts. Various sensor configurations were also investigated.

  18. A role of abdomen in butterfly's flapping flight

    Science.gov (United States)

    Jayakumar, Jeeva; Senda, Kei; Yokoyama, Naoto

    2017-11-01

    Butterfly's forward flight with periodic flapping motion is longitudinally unstable, and control of the thoracic pitching angle is essential to stabilize the flight. This study aims to comprehend roles which the abdominal motion play in the pitching stability of butterfly's flapping flight by using a two-dimensional model. The control of the thoracic pitching angle by the abdominal motion is an underactuated problem because of the limit on the abdominal angle. The control input of the thorax-abdomen joint torque is obtained by the hierarchical sliding mode control in this study. Numerical simulations reveal that the control by the abdominal motion provides short-term pitching stabilization in the butterfly's flight. Moreover, the control input due to a large thorax-abdomen joint torque can counteract a quite large perturbation, and can return the pitching attitude to the periodic trajectory with a short recovery time. These observations are consistent with biologists' view that living butterflies use their abdomens as rudders. On the other hand, the abdominal control mostly fails in long-term pitching stabilization, because it cannot directly alter the aerodynamic forces. The control for the long-term pitching stabilization will also be discussed.

  19. The DelFly design, aerodynamics, and artificial intelligence of a flapping wing robot

    CERN Document Server

    de Croon, G C H E; Remes, B D W; Ruijsink, R; De Wagter, C

    2016-01-01

    This book introduces the topics most relevant to autonomously flying flapping wing robots: flapping-wing design, aerodynamics, and artificial intelligence. Readers can explore these topics in the context of the "Delfly", a flapping wing robot designed at Delft University in The Netherlands. How are tiny fruit flies able to lift their weight, avoid obstacles and predators, and find food or shelter? The first step in emulating this is the creation of a micro flapping wing robot that flies by itself. The challenges are considerable: the design and aerodynamics of flapping wings are still active areas of scientific research, whilst artificial intelligence is subject to extreme limitations deriving from the few sensors and minimal processing onboard. This book conveys the essential insights that lie behind success such as the DelFly Micro and the DelFly Explorer. The DelFly Micro, with its 3.07 grams and 10 cm wing span, is still the smallest flapping wing MAV in the world carrying a camera, whilst the DelFly Expl...

  20. Modified cup flap for volar oblique fingertip amputations

    Directory of Open Access Journals (Sweden)

    Ahmadli, A.

    2016-02-01

    Full Text Available We describe a modified volar “V-Y cup” flap for volar fingertip defects that do not exceed more than half of the distal phalanx for better aesthetic and functional outcome. In seven cases out of eight, the flap was elevated with a subdermal pedicle, whereas in one case, the flap was elevated as an island on the bilateral neurovascular bundle. The fingertips have been evaluated for sensibility using standard tests, hook nail deformity and patient satisfaction. Seven flaps have survived completely. The flap with skeletonized bilateral digital neurovascular bundle has shown signs of venous insufficiency on the 5 postoperative day with consecutive necrosis. Suturing the distal edges of the flap in a “cupping” fashion provided a normal pulp contour. The modified flap can be used for defects as mentioned above. Subdermally dissected pedicle-based flap is safe and easy to elevate. The aesthetic and functional outcomes have been reported to be satisfactory.

  1. "The Practical Perforator Flap": the sural artery flap for lower extremity soft tissue reconstruction in wounds of war

    NARCIS (Netherlands)

    O.J.F. van Waes (Oscar); J.A. Halm (Jens); J. Vermeulen (Jefrey); S. Ashford (Sofie)

    2012-01-01

    textabstractBackground: Sural artery perforator flaps have been described for use as both local flaps and in free tissue transfer. We present the use of this flap for compound soft tissue defects of the lower limb in civilian casualties of armed conflict in Afghanistan. Methods/results: Detailed

  2. STOL Characteristics of a Propeller-Driven, Aspect-Ratio-10, Straight-Wing Airplane with Boundary-Layer Control Flaps, as Estimated from Large-Scale Wind-Tunnel Tests

    Science.gov (United States)

    Weiberg, James A; Holzhauser, Curt A.

    1961-01-01

    A study is presented of the improvements in take-off and landing distances possible with a conventional propeller-driven transport-type airplane when the available lift is increased by propeller slipstream effects and by very effective trailing-edge flaps and ailerons. This study is based on wind-tunnel tests of a 45-foot span, powered model, with BLC on the trailing-edge flaps and controls. The data were applied to an assumed airplane with four propellers and a wing loading of 50 pounds per square foot. Also included is an examination of the stability and control problems that may result in the landing and take-off speed range of such a vehicle. The results indicated that the landing and take-off distances could be more than halved by the use of highly effective flaps in combination with large amounts of engine power to augment lift (STOL). At the lowest speeds considered (about 50 knots), adequate longitudinal stability was obtained but the lateral and directional stability were unsatisfactory. At these low speeds, the conventional aerodynamic control surfaces may not be able to cope with the forces and moments produced by symmetric, as well as asymmetric, engine operation. This problem was alleviated by BLC applied to the control surfaces.

  3. [Pedicled versus free TRAM flap for breast reconstruction].

    Science.gov (United States)

    Galla, T J; Lukas, B; Feller, A M

    1999-03-01

    In breast reconstruction, the free TRAM-flap offers many advantages over the pedicled TRAM-flap. Due to its superior perfusion, the free flap rarely develops necrosis. Shaping of the flap is easier due to the lack of the thick muscle pedicle. Because the rectus muscle is spared, there is minimal donor site morbidity. However, the necessary microvascular anastomoses reduced the acceptance of the free TRAM-flap. During a 13-months period, 51 breast reconstructions were performed in 41 patients, 31 unilateral and ten bilateral. 45 flaps served for delayed reconstruction and six flaps for immediate reconstruction. The operations were performed by two teams working simultaneously. The average operating time was 3.9 hours for unilateral and 6.9 hours for bilateral delayed reconstruction. For immediate reconstruction, 6.2 and 6.3 hours were required for uni- and bilateral procedures, respectively. In 38 flaps, the thoracodorsal vessels served as recipient vessels; 13 flaps were anastomosed to the internal mammary artery and vein. Postoperative complications were observed in 13 patients. Three vessel anastomoses had to be revised. In one flap, a partial necrosis occurred; in two flaps hematoma evacuation was necessary. Two patients suffered from fat necroses at the abdomen and one umbilicus was lost. Skin irritations and seromas at the abdomen occurred in five patients. Pulmonary embolism was diagnosed in one patient three weeks postoperatively. Abdominal hernias or bulging in the epigastric area were not observed up to 15 months after reconstruction. These results reveal a low complication rate for breast reconstruction with the free TRAM-flap. The advantages of this technique as compared to the pedicled technique are discussed.

  4. Self-Propulsion of a Flapping Airfoil Using Cyber-Physical Fluid Dynamics

    Science.gov (United States)

    Young, Jay; Asselin, Daniel; Williamson, C. H. K.

    2017-11-01

    The fluid dynamics of biologically-inspired flapping propulsion provides a fertile testing ground for the field of unsteady aerodynamics, serving as important groundwork for the design and development of underwater vehicles and micro air vehicles (MAVs). These technologies can provide low cost, compact, and maneuverable means for terrain mapping, search and rescue operations, and reconnaissance. However, most laboratory experiments and simulations have been conducted using tethered airfoils with an imposed freestream velocity, which does not necessarily reflect the conditions under which an airfoil employed as a propulsor would operate. Using a closed-loop force-feedback control system, defined as Cyber-Physical Fluid Dynamics, or CPFD (Mackowski & Williamson 2011, 2015, & 2016), we allow a flapping airfoil to fly forward freely, achieving an equilibrium velocity at which thrust and drag are balanced. We study a combination of actively and passively controlled pitching and heaving dynamics in order to find motions that minimize the energy expended per distance traveled by the propulsion system. This work was supported by the National Science Foundation and the Air Force Office of Scientific Research Grant No. FA9550-15-1-0243, monitored by Dr. Douglas Smith.

  5. Release of hand burn contracture: comparing the ALT perforator flap with the gracilis free flap with split skin graft.

    Science.gov (United States)

    Misani, M; Zirak, C; Hau, Lê Thua Trung; De Mey, A; Boeckx, W

    2013-08-01

    The use of microsurgery in the management of burn sequelae is not a new idea. According to the properties of various types of free flaps different goals can be achieved or various additional procedures have to be combined. We report the comparison of two different free flaps on a single patient for reconstruction of both upper extremities for burn sequelae. A 1-year-old child sustained severe burns on both hands, arms and thorax and was initially only treated conservatively. This resulted in severe contractures. At the age of 4-years a free gracilis flap was selected for reconstruction of his left hand and a free anterolateral thigh flap for the right hand. We noticed a better functional and esthetic result for the gracilis flap associated with a shorter operative time and a minor donor site morbidity. The intraoperative technique and time, postoperative complications, functional and esthetic results and donor site morbidities were studied in the two types of flaps chosen. A review of literature was also performed. Our experience reported a better success of the gracilis muscle flap covered with a split skin graft compared to the anterolateral thigh flap in the reconstruction of hand function after severe burn sequelae. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  6. The adverse effect of selective cyclooxygenase-2 inhibitor on random skin flap survival in rats.

    Directory of Open Access Journals (Sweden)

    Haiyong Ren

    Full Text Available BACKGROUND: Cyclooxygenase-2(COX-2 inhibitors provide desired analgesic effects after injury or surgery, but evidences suggested they also attenuate wound healing. The study is to investigate the effect of COX-2 inhibitor on random skin flap survival. METHODS: The McFarlane flap model was established in 40 rats and evaluated within two groups, each group gave the same volume of Parecoxib and saline injection for 7 days. The necrotic area of the flap was measured, the specimens of the flap were stained with haematoxylin-eosin(HE for histologic analysis. Immunohistochemical staining was performed to analyse the level of VEGF and COX-2 . RESULTS: 7 days after operation, the flap necrotic area ratio in study group (66.65 ± 2.81% was significantly enlarged than that of the control group(48.81 ± 2.33%(P <0.01. Histological analysis demonstrated angiogenesis with mean vessel density per mm(2 being lower in study group (15.4 ± 4.4 than in control group (27.2 ± 4.1 (P <0.05. To evaluate the expression of COX-2 and VEGF protein in the intermediate area II in the two groups by immunohistochemistry test .The expression of COX-2 in study group was (1022.45 ± 153.1, and in control group was (2638.05 ± 132.2 (P <0.01. The expression of VEGF in the study and control groups were (2779.45 ± 472.0 vs (4938.05 ± 123.6(P <0.01.In the COX-2 inhibitor group, the expressions of COX-2 and VEGF protein were remarkably down-regulated as compared with the control group. CONCLUSION: Selective COX-2 inhibitor had adverse effect on random skin flap survival. Suppression of neovascularization induced by low level of VEGF was supposed to be the biological mechanism.

  7. Dorsal hand coverage with free serratus fascia flap

    DEFF Research Database (Denmark)

    Fotopoulos, Peter; Holmer, Per; Leicht, Pernille

    2003-01-01

    in the flap, leaving the long thoracic nerve intact on the serratus muscle. Coverage of the flap with split-thickness skin graft is done immediately. The free serratus fascia flap is an ideal flap for dorsal hand coverage when the extensor tendons are exposed, especially because of low donor-site morbidity....

  8. Chronic Open Infective Lateral Malleolus Bursitis Management Using Local Rotational Flap

    Directory of Open Access Journals (Sweden)

    Yong-Beom Lee

    2017-01-01

    Full Text Available Background. Using a sinus tarsi rotational flap is an uncommon approach to treating chronic open infective lateral malleolus bursitis. Methods. We treated eight patients, including six males, using this approach. First, we debrided all the infected tissues and used a negative pressure wound closure system where needed. After acute infection had been controlled, the local rotational flap was used for cases where the wound could not be closed by a simple suture or bone exposure. The rotational flap was detached with a curved skin incision at the sinus tarsi next to the open wound and sutured to the defect, paying careful attention to the superficial peroneal nerve. The donor site was managed with a split-thickness skin graft. Results. The patients’ mean age was 74.1 years. Six patients had a wound after suppurative infection, but two patients had ulcer-type bursitis. Six patients demonstrated full flap healing, but two patients had venous congestion necrosis. Conclusion. A sinus tarsi rotational flap is a useful method to ensure healing and coverage of chronic open lateral malleolus bursitis, especially for small to medium wounds with cavity and bone exposure.

  9. Dermatosurgery Rounds - The Island SKIN Infraorbital Flap

    Directory of Open Access Journals (Sweden)

    Georgi Tchernev

    2017-07-01

    Full Text Available The main objective in dermatologic surgery is complete excision of the tumour while achieving the best possible functional and cosmetic outcome. Also we must take into account age, sex, and tumour size and site. We should also consider the patient's expectations, the preservation of the different cosmetic units, and the final cosmetic outcome. Various reconstructive methods ranging from secondary healing to free flap applications are usedfor the reconstruction of perinasal or facial defects caused by trauma or tumour surgery. Herein, we describe the nasal infraorbital island skin flap for the reconstruction in a patient with basal cell carcinoma. No complications were observed in operation field. The infraorbital island skin flap which we describe for the perinasal area reconstruction is a safe, easily performed and versatile flap. The multidimensional use of this flap together with a relatively easy reconstruction plan and surgical procedure would be effective in flap choice.

  10. Prospective evaluation of outcome measures in free-flap surgery.

    LENUS (Irish Health Repository)

    Kelly, John L

    2004-08-01

    Free-flap failure is usually caused by venous or arterial thrombosis. In many cases, lack of experience and surgical delay also contribute to flap loss. The authors prospectively analyzed the outcome of 57 free flaps over a 28-month period (January, 1999 to April, 2001). The setting was a university hospital tertiary referral center. Anastomotic technique, ischemia time, choice of anticoagulant, and the grade of surgeon were recorded. The type of flap, medications, and co-morbidities, including preoperative radiotherapy, were also documented. Ten flaps were re-explored (17 percent). There were four cases of complete flap failure (6.7 percent) and five cases of partial failure (8.5 percent). In patients who received perioperative systemic heparin or dextran, there was no evidence of flap failure (p = .08). The mean ischemia time was similar in flaps that failed (95 +\\/- 29 min) and in those that survived (92 +\\/- 34 min). Also, the number of anastomoses performed by trainees in flaps that failed (22 percent), was similar to the number in flaps that survived (28 percent). Nine patients received preoperative radiotherapy, and there was complete flap survival in each case. This study reveals that closely supervised anastomoses performed by trainees may have a similar outcome to those performed by more senior surgeons. There was no adverse effect from radiotherapy or increased ischemia time on flap survival.

  11. Precision Position Control of the DelFly II Flapping-wing Micro Air Vehicle in a Wind-tunnel

    NARCIS (Netherlands)

    Cunis, T.; Karasek, M.; de Croon, G.C.H.E.

    2016-01-01

    Flapping-wing MAVs represent an attractive alternative to conventional designs with rotary wings, since they promise a much higher efficiency in forward flight. However, further insight into the flapping-wing aerodynamics is still needed to get closer to the flight performance observed in natural

  12. [Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].

    Science.gov (United States)

    Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua

    2017-03-01

    To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.

  13. Cannula-Assisted Flap Elevation (CAFE): a novel technique for developing flaps during skin-sparing mastectomies.

    Science.gov (United States)

    Grant, Michael D

    2015-02-01

    One of the most challenging procedures in breast surgery is the skin-sparing mastectomy (SSM). Various techniques and incisions have evolved that characterize this procedure; however, what is common in all of them is the smaller the incision, the more difficult it is to develop the skin flaps. A procedure was developed that incorporates the use of liposuction cannulas (without suction) to create the skin flaps. The technique and results are described in this manuscript. From October of 2012 to April 2014, 289 mastectomies (171 patients) were performed using the CAFE procedure on women of all shapes and sizes. Postoperatively, no problems were experienced with flap viability using this technique. The main difference in side effects between the CAFE technique and other standard techniques for developing flaps in SSMs was more bruising than normal, but this resolved rapidly. The results for use of this technique were consistently impressive. The learning curve for this procedure is very short, especially for those who perform SSMs using sharp technique (scissors). Residents and fellows became proficient with the CAFE technique in a relatively short amount of time. Plastic surgeons were pleased with the cosmetic outcomes of their reconstructions that follow this type of mastectomy. Patients were extremely satisfied with their reconstructions as well. Incorporating the use of liposuction cannulas (without suction) makes the creation of flaps for SSM a relatively simple and rapid method. It is especially useful to assist in developing skin flaps with even the smallest of skin incisions.

  14. The Effects of Passive Cigarette Smoke Exposure on the Survival of the Reverse Sural Fasciocutaneous Flap.

    Science.gov (United States)

    Sadagatullah, Abdul Nawfar; Halim, Ahmad Sukari; Bathusha, Mohd Shakir; Ramachandran, Anantha Kumar

    2017-12-01

    Background  The possibility of a person who had undergone surgery to be exposed to the ill effects of cigarette smoke is high, more so if the person lives with a smoker. With increasing popularity of reverse sural fasciocutaneous flaps, a surgeon may have to manage a person who lives with a smoker or is exposed to cigarette smoke. A clear understanding of the effects of exposure to cigarette smoke on reverse sural fasciocutaneous flaps is necessary. This study was performed to establish a clearer understanding of the effects of smoking on reverse sural fasciocutaneous flaps and evidence for preoperative patient counseling about smoking and smoke exposure. Objective  The study investigated effects of exposure to cigarette smoke on the survival of the reverse sural fasciocutaneous flap. Methods  This was an experimental observational study conducted at the Laboratory for Animal Research Unit in the Health Campus of Universiti Sains Malaysia. Twelve adult White New Zealand rabbits ( Oryctolagus cuniculus ) were divided into two groups of six. All 12 rabbits had a 2.5- × 2.5-cm reverse sural fasciocutaneous flap raised on both its hind limbs. The group exposed to cigarette smoke underwent 4 weeks of smoke exposure for 2 hours daily prior to surgery. This was then continued until analysis of the results. The control group had no intervention. All flaps were analyzed on the seventh postoperative day, after tracing on transparent plastic sheets with the necrotic area marked followed by 2D planimetry done on a grid paper. The flaps were assessed on the total flap area and survival area percentage. It was recorded as mean ± SD. The presence or absence of infection and hematoma was also noted. Results  Twelve flaps were analyzed in each group. Total mean flap area and survival area percentage of the control group were 120.33 ± 31.03 mm 2 and 80.12 ± 15.75%, respectively, whereas in the cigarette smoke-exposed group, it was 121.83 ± 17.93 mm 2

  15. Global-local optimization of flapping kinematics in hovering flight

    KAUST Repository

    Ghommem, Mehdi; Hajj, M. R.; Mook, Dean T.; Stanford, Bret K.; Bé ran, Philip S.; Watson, Layne T.

    2013-01-01

    The kinematics of a hovering wing are optimized by combining the 2-d unsteady vortex lattice method with a hybrid of global and local optimization algorithms. The objective is to minimize the required aerodynamic power under a lift constraint. The hybrid optimization is used to efficiently navigate the complex design space due to wing-wake interference present in hovering aerodynamics. The flapping wing is chosen so that its chord length and flapping frequency match the morphological and flight properties of two insects with different masses. The results suggest that imposing a delay between the different oscillatory motions defining the flapping kinematics, and controlling the way through which the wing rotates at the end of each half stroke can improve aerodynamic power under a lift constraint. Furthermore, our optimization analysis identified optimal kinematics that agree fairly well with observed insect kinematics, as well as previously published numerical results.

  16. Global-local optimization of flapping kinematics in hovering flight

    KAUST Repository

    Ghommem, Mehdi

    2013-06-01

    The kinematics of a hovering wing are optimized by combining the 2-d unsteady vortex lattice method with a hybrid of global and local optimization algorithms. The objective is to minimize the required aerodynamic power under a lift constraint. The hybrid optimization is used to efficiently navigate the complex design space due to wing-wake interference present in hovering aerodynamics. The flapping wing is chosen so that its chord length and flapping frequency match the morphological and flight properties of two insects with different masses. The results suggest that imposing a delay between the different oscillatory motions defining the flapping kinematics, and controlling the way through which the wing rotates at the end of each half stroke can improve aerodynamic power under a lift constraint. Furthermore, our optimization analysis identified optimal kinematics that agree fairly well with observed insect kinematics, as well as previously published numerical results.

  17. Smart rotor modeling aero-servo-elastic modeling of a smart rotor with adaptive trailing edge flaps

    CERN Document Server

    Bergami, Leonardo

    2014-01-01

    A smart rotor is a wind turbine rotor that, through a combination of sensors, control units and actuators actively reduces the variation of the aerodynamic loads it has to withstand. Smart rotors feature?promising load alleviation potential and might provide the technological breakthrough required by the next generation of large wind turbine rotors.The book presents the aero-servo-elastic model of a smart rotor with Adaptive Trailing Edge Flaps for active load alleviation and provides an insight on the rotor aerodynamic, structural and control modeling. A novel model for the unsteady aerodynam

  18. The prepuce free flap in 10 patients : modifications in flap design and surgical technique

    NARCIS (Netherlands)

    Werker, Paul M N

    The prepuce free flap was used in 10 oral and oropharyngeal reconstructions. During the course of this study, various modifications took place. Residual penile skin necrosis and skin island necrosis early in the series led to modification of flap design. This solved the donor-site problem by placing

  19. Carbon dioxide laser for de-epithelialization of periodontal flaps.

    Science.gov (United States)

    Centty, I G; Blank, L W; Levy, B A; Romberg, E; Barnes, D M

    1997-08-01

    Regeneration of mineralized and soft connective tissue components of the attachment apparatus is the main goal in the treatment of periodontal diseases. Often, apical migration of epithelium (long junctional epithelium) effectively prevents the formation of bone and connective tissue attachment after periodontal surgery. The purpose of the present study was to compare conventional periodontal surgery combined with carbon dioxide laser and conventional periodontal surgery alone with respect to epithelial elimination and degree of necrosis of mucoperiosteal flaps. After signing a consent form, five patients with at least two comparable bilateral periodontal defects needing pocket elimination surgery participated in this study. The investigators randomly divided each side into test and control sites. Each patient received oral hygiene instruction and initial therapy prior to surgery. At surgery, the test site received a sulcular incision and carbon dioxide laser de-epithelialization of the outer and inner aspects of the flap. The control group received reverse bevel incision only. The surgeon performed open flap debridement on all teeth. At the time of surgery, the surgeon did a biopsy of each site and submitted specimens for histologic evaluation. A matched pairs t-test was used to analyze the data. The results show significant differences between the carbon dioxide laser and reverse bevel incision with respect to sulcular (P test sites, with a predominance of plasma cells. Lining the sulcular and gingival (external) lased areas, investigators found coagulation necrosis covered by fibrin and coagulated blood. The laser appears to effectively remove epithelium at the time of surgery; however, future long-term, well-controlled quantitative histologic studies are needed to evaluate the effect of repeated carbon dioxide laser de-epithelialization of the gingival (external) surface of mucoperiosteal flaps at intervals during the healing period.

  20. Dual omental flap in obliterating post-pneumonectomy ...

    African Journals Online (AJOL)

    Background: Post-pneumonectomy bronchopleural fistulae is associated with high mortality and morbidity. The omental flap has been widely used to manage this condition either through laparoscopic or open surgery with varied degrees of success. We present a modification of the omental flap by using two flaps of the ...

  1. Vascularized Fibula Flaps for Mandibular Reconstruction: An ...

    African Journals Online (AJOL)

    For decades, osseous vascularised flaps have been used for reconstruction of the mandible with the vascularised fibula flap (VFF) remaining the commonly used osseous free flap, reasons ranging from its adequate bone and pedicle length to its receptive dental implant placement quality. This report considers a modest use ...

  2. Reconstruction of pressure sores with perforator-based propeller flaps.

    Science.gov (United States)

    Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G

    2011-03-01

    Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.

  3. Colgajo perforante tóracodorsal Toracodorsal perforator flap

    Directory of Open Access Journals (Sweden)

    C. Angrigiani

    2006-12-01

    Full Text Available La espalda es una excelente zona dadora de colgajos. El colgajo perforante tóracodorsal basado en ramas cutáneas de la arteria y vena tóracodorsales que perforan el músculo dorsal ancho, es una modifica ción del tradicional colgajo musculocutáneo de dorsal ancho que permite lograr una mayor flexibilidad en su traslado y una disminución de su volumen. Puede emplearse como colgajo libre o en isla. Presentamos su anatomía, disección e indicaciones.Back is an excellent donor site for flaps. The tora codorsal perforator flap, based on cutaneous vessels from toracodorsal artery and vein that pass through Latissimus Dorsi muscle, is a modified conventional musculocutaneous Latissimus Dorsi flap that allows easier movility and a volume reduction. This flap can be used both, free flap or island flap. We present the anatomy, dissection and applica tions of this flap.

  4. Aromatic residues located close to the active center are essential for the catalytic reaction of flap endonuclease-1 from hyperthermophilic archaeon Pyrococcus horikoshii.

    Science.gov (United States)

    Matsui, Eriko; Abe, Junko; Yokoyama, Hideshi; Matsui, Ikuo

    2004-04-16

    Flap endonuclease-1 (FEN-1) possessing 5'-flap endonuclease and 5'-->3' exonuclease activity plays important roles in DNA replication and repair. In this study, the kinetic parameters of mutants at highly conserved aromatic residues, Tyr33, Phe35, Phe79, and Phe278-Phe279, in the vicinity of the catalytic centers of FEN-1 were examined. The substitution of these aromatic residues with alanine led to a large reduction in kcat values, although these mutants retained Km values similar to that of the wild-type enzyme. Notably, the kcat of Y33A and F79A decreased 333-fold and 71-fold, respectively, compared with that of the wild-type enzyme. The aromatic residues Tyr33 and Phe79, and the aromatic cluster Phe278-Phe279 mainly contributed to the recognition of the substrates without the 3' projection of the upstream strand (the nick, 5'-recess-end, single-flap, and pseudo-Y substrates) for the both exo- and endo-activities, but played minor roles in recognizing the substrates with the 3' projection (the double flap substrate and the nick substrate with the 3' projection). The replacement of Tyr33, Phe79, and Phe278-Phe279, with non-charged aromatic residues, but not with aliphatic hydrophobic residues, recovered the kcat values almost fully for the substrates without the 3' projection of the upstream strand, suggesting that the aromatic groups of Tyr33, Phe79, and Phe278-Phe279 might be involved in the catalytic reaction, probably via multiple stacking interactions with nucleotide bases. The stacking interactions of Tyr33 and Phe79 might play important roles in fixing the template strand and the downstream strand, respectively, in close proximity to the active center to achieve the productive transient state leading to the hydrolysis.

  5. All-Ceramic Body Flap Qualified for Space Flight on X38

    Science.gov (United States)

    Pfeiffer, H.; Peetz, K.

    2002-01-01

    Ceramic matrix composite (CMC) materials allow design of high-temperature resistant, light and robust structures. CMC materials with silicon-carbide matrix reinforced by carbon fibers (C/SiC) show constant strength and damage-tolerant behavior up to very high temperatures. CMC thermal protection systems and hot structures have been developed in Europe over many years. MAN Technologie developed the necessary technologies to create the technological basis for CMC structures for future, more economical and reusable launch vehicles. Within the German space technology program TETRA (Technologies for Future Space Transportation Systems) body flaps were developed for X-38 by MAN Technologie. Key technologies like high strength oxidation protected CMC materials, manufacturing processes for large and complex structures, advanced high temperature lubricant coating combinations for bearings, joining with ceramic fasteners, metal-to-ceramic interfaces as well as dynamic seals are required for hot structures like control surfaces for re-entry vehicles. Because of the high heat and mechanical loads of a lifting body together with the low mass requirements the body flaps for NASA's X-38 re-entry vehicle V-201were selected to demonstrate as a first flight maturity of a large and complex ceramic structure. The flaps are designed as an all-ceramic, load-carrying hot structure, which needs no heavy metallic primary structure and no additional thermal protection tiles and subsequently offers considerable mass and volume savings. The X-38 body flaps are conceived as a revolutionary step forward. The twin flaps, each with the size of 1.6 m x 1.4 m (5.25 ft x 4.6 ft) and the low weight of 68 kg (150 lb) are all made of C/SiC material to operate up to temperatures of 1800 C (3.270 F) in oxidizing atmosphere while they are deflectable under high mechanical loads up to 50 kN (11.260 lbf) at the same time. The flaps are deflected about the hinge axis on two ceramic bearings and moved by an

  6. Design and development of an active Gurney flap for rotorcraft

    Science.gov (United States)

    Freire Gómez, Jon; Booker, Julian D.; Mellor, Phil H.

    2013-03-01

    The EU's Green Rotorcraft programme will develop an Active Gurney Flap (AGF) for a full-scale helicopter main rotor blade as part of its `smart adaptive rotor blade' technology demonstrators. AGFs can be utilized to provide a localized and variable lift enhancement on the rotor, enabling a redistribution of loading on the rotor blade around the rotor azimuth. Further advantages include the possibility of using AGFs to allow a rotor speed reduction, which subsequently provides acoustic benefits. Designed to be integrable into a commercial helicopter blade, and thereby capable of withstanding real in-flight centrifugal loading, blade vibrations and aerodynamic loads, the demonstrator is expected to achieve a high technology readiness level (TRL). The AGF will be validated initially by a constant blade section 2D wind tunnel test and latterly by full blade 3D whirl tower testing. This paper presents the methodology adopted for the AGF concept topology selection, based on a series of both qualitative and quantitative performance criteria. Two different AGF candidate mechanisms are compared, both powered by a small commercial electromagnetic actuator. In both topologies, the link between the actuator and the control surface consists of two rotating torque bars, pivoting on flexure bearings. This provides the required reliability and precision, while making the design virtually frictionless. The engineering analysis presented suggests that both candidates would perform satisfactorily in a 2D wind tunnel test, but that equally, both have design constraints which limit their potential to be further taken into a whirl tower test under full scale centrifugal and inertial loads.

  7. Power Requirements for Bi-Harmonic Amplitude and Bias Modulation Control of a Flapping Wing Micro Air Vehicle

    Science.gov (United States)

    2013-03-01

    nature, would have the inherent benefit of stealth through mimicry of insects. Such a MAV is referred to as a flapping wing micro air vehicle (FWMAV...Insect exoskeletons are formed from a complex blend of polymer-based chains that make up the body, limbs, and wings, which act as a barrier between the...reducing weight, increasing agility, and integrating robotics in future forces. [38] Increasing agility and integrating robotics indicates that control is a

  8. The Vasodilator Effect of a Cream Containing 10% Menthol and 15% Methyl Salicylate on Random-Pattern Skin Flaps in Rats.

    Science.gov (United States)

    Dölen, Utku Can; Sungur, Nezih; Koca, Gökhan; Ertunç, Onur; Bağcı Bosi, Ayşe Tülay; Koçer, Uğur; Korkmaz, Meliha

    2015-11-01

    It is still difficult to prevent partial or full-thickness flap necrosis. In this study, the effects of a cream containing menthol and methyl salicylate on the viability of randompattern skin flaps were studied. Forty female Sprague-Dawley rats were divided into two equal groups. Caudally based dorsal random-pattern skin flaps were elevated, including the panniculus carnosus. In the study group, 1.5 mL of a cream containing menthol and methyl salicylate was applied to the skin of the flap, and saline solution (0.9%) was used in the control group. Upon completion of the experiment, flap necrosis was analyzed with imaging software and radionuclide scintigraphy. Histopathological measurements were made of the percentage of viable flaps, the number of vessels, and the width of the panniculus carnosus muscle. According to the photographic analysis, the mean viable flap surface area in the study group was larger than that in the control group (P=0.004). According to the scintigrams, no change in radioactivity uptake was seen in the study group (P>0.05). However, a significant decrease was observed in the control group (P=0.006). No statistically significant differences were observed between the groups in terms of the percentage of viable flaps, the number of vessels, or the width of the panniculus carnosus muscle (P>0.05). Based on these results, it is certain that the cream did not reduce the viability of the flaps. Due to its vasodilatory effect, it can be used as a component of the dressing in reconstructive operations where skin perfusion is compromised.

  9. Lift production through asymmetric flapping

    Science.gov (United States)

    Jalikop, Shreyas; Sreenivas, K. R.

    2009-11-01

    At present, there is a strong interest in developing Micro Air Vehicles (MAV) for applications like disaster management and aerial surveys. At these small length scales, the flight of insects and small birds suggests that unsteady aerodynamics of flapping wings can offer many advantages over fixed wing flight, such as hovering-flight, high maneuverability and high lift at large angles of attack. Various lift generating mechanims such as delayed stall, wake capture and wing rotation contribute towards our understanding of insect flight. We address the effect of asymmetric flapping of wings on lift production. By visualising the flow around a pair of rectangular wings flapping in a water tank and numerically computing the flow using a discrete vortex method, we demonstrate that net lift can be produced by introducing an asymmetry in the upstroke-to-downstroke velocity profile of the flapping wings. The competition between generation of upstroke and downstroke tip vortices appears to hold the key to understanding this lift generation mechanism.

  10. Versatality of Nasolabial Flap in Orofacial Reconstruction

    Directory of Open Access Journals (Sweden)

    Nandesh Shetty

    2015-01-01

    Materials and Methods: A total of 10 patients were selected based on the size of surgical defect. Nasolabial flap was used to reconstruct defects of small to moderate size in the oro-facial region and post-operative follow up was done. Results: All of the patients underwent inferiorly based Transposition Island flap for reconstruction of different oro-facial defects. Few complications like bulky size of the flap, slight donor site distortion (scar formation and intra-oral hair growth were seen in six patients. Two incidences of infection in the transferred flap were seen. Conclusion: It is a safe minor procedure done under general anesthesia with good reconstructive results over small or moderately sized maxillofacial defects. Proper attention to flap design, operative technique and post - operative management are useful in reducing the incidence of complications.

  11. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available BackgroundRobots have allowed head and neck surgeons to extirpate oropharyngeal tumors safely without the need for lip-split incision or mandibulotomy. Using robots in oropharyngeal reconstruction is new but essential for oropharyngeal defects that result from robotic tumor excision. We report our experience with robotic free-flap reconstruction of head and neck defects to exemplify the necessity for robotic reconstruction.MethodsWe investigated head and neck cancer patients who underwent ablation surgery and free-flap reconstruction by robot. Between July 1, 2011 and March 31, 2012, 5 cases were performed and patient demographics, location of tumor, pathologic stage, reconstruction methods, flap size, recipient vessel, necessary pedicle length, and operation time were investigated.ResultsAmong five free-flap reconstructions, four were radial forearm free flaps and one was an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and one flap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flap insetting and microanastomosis were achieved using a specially manufactured robotic instrument. The total operation time was 1,041.0 minutes (range, 814 to 1,132 minutes, and complications including flap necrosis, hematoma, and wound dehiscence did not occur.ConclusionsThis study demonstrates the clinically applicable use of robots in oropharyngeal reconstruction, especially using a free flap. A robot can assist the operator in insetting the flap at a deep portion of the oropharynx without the need to perform a traditional mandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methods and is accepted as the most up-to-date method.

  12. Flow field of flexible flapping wings

    Science.gov (United States)

    Sallstrom, Erik

    The agility and maneuverability of natural fliers would be desirable to incorporate into engineered micro air vehicles (MAVs). However, there is still much for engineers to learn about flapping flight in order to understand how such vehicles can be built for efficient flying. The goal of this study is to develop a methodology for capturing high quality flow field data around flexible flapping wings in a hover environment and to interpret it to gain a better understanding of how aerodynamic forces are generated. The flow field data was captured using particle image velocimetry (PIV) and required that measurements be taken around a repeatable flapping motion to obtain phase-averaged data that could be studied throughout the flapping cycle. Therefore, the study includes the development of flapping devices with a simple repeatable single degree of freedom flapping motion. The acquired flow field data has been examined qualitatively and quantitatively to investigate the mechanisms behind force production in hovering flight and to relate it to observations in previous research. Specifically, the flow fields have been investigated around a rigid wing and several carbon fiber reinforced flexible membrane wings. Throughout the whole study the wings were actuated with either a sinusoidal or a semi-linear flapping motion. The semi-linear flapping motion holds the commanded angular velocity nearly constant through half of each half-stroke while the sinusoidal motion is always either accelerating or decelerating. The flow fields were investigated by examining vorticity and vortex structures, using the Q criterion as the definition for the latter, in two and three dimensions. The measurements were combined with wing deflection measurements to demonstrate some of the key links in how the fluid-structure interactions generated aerodynamic forces. The flow fields were also used to calculate the forces generated by the flapping wings using momentum balance methods which yielded

  13. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction

    NARCIS (Netherlands)

    Hekner, D.D.; Roeling, TAP; van Cann, EM

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were

  14. Bilirubin provides perforator flap protection from ischaemia-reperfusion injury in a rat model: a preliminary result.

    Science.gov (United States)

    Kim, Sung Young; Rah, Dong Kyun; Chong, Yosep; Lee, Song Hyun; Park, Tae Hwan

    2016-10-01

    The use of bilirubin, a well-known and powerful antioxidant, has gained popularity in recent years because of its role in the prevention of ischaemic heart disease in patients with Gilbert's syndrome. We investigate the effects of bilirubin on ischaemia-reperfusion (I/R) injury using a rat perforator flap model. Forty-eight rats were randomly divided into two groups: experimental (bilirubin) group (n = 24) and control group (n = 24). In each group, elevated bilateral deep inferior epigastric perforator (DIEP) flaps were created. The right (no ischaemia side) and left (ischaemia side) DIEP flaps were separated according to the presence of ischaemia induction. Ischaemia was induced in anaesthetised rats by perforator clamping for 15 or 30 minutes. After surgery, the flap survival was assessed daily on postoperative days 0 to 5, and overall histological changes of DIEP flaps above the perforator were analysed at postoperative day 5. The flap survival rate in the bilirubin group was significantly higher than that in the control group at the ischaemia side following perforator clamping for 15 or 30 minutes (93·42 ± 4·48% versus 89·63 ± 3·98%, P = 0·002; and 83·96 ± 4·23% versus 36·46 ± 6·38%, P bilirubin was found to alleviate perforator flap necrosis caused by I/R injury in this experimental rat model. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  15. Perforator plus flaps: Optimizing results while preserving function and esthesis

    Directory of Open Access Journals (Sweden)

    Mehrotra Sandeep

    2010-01-01

    Full Text Available Background: The tenuous blood supply of traditional flaps for wound cover combined with collateral damage by sacrifice of functional muscle, truncal vessels, or nerves has been the bane of reconstructive procedures. The concept of perforator plus flaps employs dual vascular supply to flaps. By safeguarding perforators along with supply from its base, robust flaps can be raised in diverse situations. This is achieved while limiting collateral damage and preserving nerves, vessels, and functioning muscle with better function and aesthesis. Materials and Methods: The perforator plus concept was applied in seven different clinical situations. Functional muscle and fasciocutaneous flaps were employed in five and adipofascial flaps in two cases, primarily involving lower extremity defects and back. Adipofascial perforator plus flaps were employed to provide cover for tibial fracture in one patients and chronic venous ulcer in another. Results: All flaps survived without any loss and provided long-term stable cover, both over soft tissue and bone. Functional preservation was achieved in all cases where muscle flaps were employed with no clinical evidence of loss of power. There was no sensory loss or significant oedema in or distal to the flap in both cases where neurovascular continuity was preserved during flap elevation. Fracture union and consolidation were satisfactory. One patient had minimal graft loss over fascia which required application of stored grafts with subsequent take. No patient required re-operation. Conclusions: Perforator plus concept is holistic and applicable to most flap types in varied situations. It permits the exercise of many locoregional flap options while limiting collateral functional damage. Aesthetic considerations are also addressed while raising adipofascial flaps because of no appreciable donor defects. With quick operating times and low failure risk, these flaps can be a better substitute to traditional flaps and at

  16. A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft.

    Science.gov (United States)

    Lim, Hyoseob; Han, Dae Hee; Lee, Il Jae; Park, Myong Chul

    2014-03-01

    Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.

  17. A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft

    Directory of Open Access Journals (Sweden)

    Hyoseob Lim

    2014-03-01

    Full Text Available Background Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. Methods We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Results Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. Conclusions A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.

  18. Repair of nostril stenosis using a triple flap combination: boomerang, nasolabial, and vestibular rotation flaps.

    Science.gov (United States)

    Bozkurt, Mehmet; Kapi, Emin; Kuvat, Samet Vasfi; Selçuk, Caferi Tayyar

    2012-11-01

    Tissue losses within the nose due to various reasons result in the loss of normal anatomy and function. The external nasal valve area is one of the most important functional components of the nose. The columella, lobule, nostril, and alar region are among the components forming the external nasal valve area. Deformities of the nostrils are among the most frequently observed features that interfere with the functional anatomy of the nose. Malformations of the nostrils often emerge subsequent to cleft lip repairs. Stenoses are a common type of pathology among nostril deformities. In cases where a stenosis has formed, breathing problems and developmental anomalies may occur. In the patient with nostril stenosis presented in this report, there was a serious alar collapse and contracture subsequent to a cleft lip repair. In order to repair the nostril stenosis, a "boomerang flap" was chosen. This boomerang flap was used in combination with a nasolabial flap, a vestibular rotation flap, and a conchal cartilage graft to achieve a satisfactory repair.

  19. Triple flap technique for vulvar reconstruction.

    Science.gov (United States)

    Mercut, R; Sinna, R; Vaucher, R; Giroux, P A; Assaf, N; Lari, A; Dast, S

    2018-04-09

    Perineal defects are encountered ever more frequently, in the treatment of vulvar cancers or abdominoperineal resection. The surgical treatment of vulvar cancer leads to significant skin defect. The aim of the reconstruction is not to provide volume but rather to resurface perineum. We propose a new solution to cover the extensive skin defect remaining after excision. We report 3 patients who underwent large excision for vulvar cancer, with lymph node dissection. For reconstruction, we performed 3 advancement flaps. Two V-Y flaps cantered on the infra-gluteal folds and based on pudendal perforator arteries were used to cover the postero-lateral parts of the defect. The third advancement flap from the superior aspect of the defect was a Y-V Mons pubis flap. The defects were successfully covered by the 3 flap technique. The first patient suffered a non-union that slowly healed by secondary intention. For the other cases, we used the same technique, but applied negative pressure wound therapy on the sutures, with excellent results. The 3 flap technique is a simple and reliable method and the donor site morbidity is minimal. It can be realised without changing the position of the patient after tumour excision, and does not require delicate perforator dissection. This surgical option can be easily applied, allowing better management of these cases. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  20. "Internet of Things" Real-Time Free Flap Monitoring.

    Science.gov (United States)

    Kim, Sang Hun; Shin, Ho Seong; Lee, Sang Hwan

    2018-01-01

    Free flaps are a common treatment option for head and neck reconstruction in plastic reconstructive surgery, and monitoring of the free flap is the most important factor for flap survival. In this study, the authors performed real-time free flap monitoring based on an implanted Doppler system and "internet of things" (IoT)/wireless Wi-Fi, which is a convenient, accurate, and efficient approach for surgeons to monitor a free flap. Implanted Doppler signals were checked continuously until the patient was discharged by the surgeon and residents using their own cellular phone or personal computer. If the surgeon decided that a revision procedure or exploration was required, the authors checked the consumed time (positive signal-to-operating room time) from the first notification when the flap's status was questioned to the determination for revision surgery according to a chart review. To compare the efficacy of real-time monitoring, the authors paired the same number of free flaps performed by the same surgeon and monitored the flaps using conventional methods such as a physical examination. The total survival rate was greater in the real-time monitoring group (94.7% versus 89.5%). The average time for the real-time monitoring group was shorter than that for the conventional group (65 minutes versus 86 minutes). Based on this study, real-time free flap monitoring using IoT technology is a method that surgeon and reconstruction team can monitor simultaneously at any time in any situation.

  1. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction.

    Science.gov (United States)

    Hekner, D D; Roeling, T A P; Van Cann, E M

    2016-08-01

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were injected with epoxy resin (Araldite) and the perforating arteries were dissected. The number of clinically relevant perforators from the radial and ulnar arteries was not significantly different in the distal forearm. Most perforators were located in the proximal half of the distal one third, making this part probably the safest location for flap harvest. Close to the wrist, i.e. most distally, there were more perforators on the ulnar side than on the radial side. The ulnar artery stained 77% of the skin surface area of the forearm, showing the ulnar forearm free flap to be more suitable than the radial forearm free flap for the restoration of large defects. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. EXTENDED REVERSE SURAL FLAP FOR LOWER LIMB COVERAGE

    Directory of Open Access Journals (Sweden)

    Biswajit Mishra

    2018-12-01

    Full Text Available BACKGROUND The reverse sural artery flap has been a workhorse for the reconstruction of distal third of leg, ankle, sole and foot. Major limitation of reverse sural flap has been venous congestion particularly when harvested from proximal third of the leg. Objective- To evaluate the efficacy, safety of the extended reverse sural flap from proximal third of the leg. MATERIALS AND METHODS A prospective study was conducted at the department of plastic surgery on twenty patients who needed soft tissue reconstruction in the distal third of the leg, ankle, heel, forefoot and midfoot due to various cause. In all cases flap was extended proximally to the upper third of the calf and neurovenoadipo fascial pedicled sural fasciocutaneous flap was harvested. RESULTS There were only two cases of marginal necrosis. None of the patients had complete necrosis. Two patients developed hypertrophy of the flap margin. CONCLUSION Distally based neuroveno adipofascial pedicled sural fasciocutaneous flap can be safely extended to proximal third of the leg and is a reliable option for reconstruction of the defects in the foot, ankle and sole.

  3. Simulation Study of Flap Effects on a Commercial Transport Airplane in Upset Conditions

    Science.gov (United States)

    Cunningham, Kevin; Foster, John V.; Shah, Gautam H.; Stewart, Eric C.; Ventura, Robin N.; Rivers, Robert A.; Wilborn, James E.; Gato, William

    2005-01-01

    As part of NASA's Aviation Safety and Security Program, a simulation study of a twinjet transport airplane crew training simulation was conducted to address fidelity for upset or loss of control conditions and to study the effect of flap configuration in those regimes. Piloted and desktop simulations were used to compare the baseline crew training simulation model with an enhanced aerodynamic model that was developed for high-angle-of-attack conditions. These studies were conducted with various flap configurations and addressed the approach-to-stall, stall, and post-stall flight regimes. The enhanced simulation model showed that flap configuration had a significant effect on the character of departures that occurred during post-stall flight. Preliminary comparisons with flight test data indicate that the enhanced model is a significant improvement over the baseline. Some of the unrepresentative characteristics that are predicted by the baseline crew training simulation for flight in the post-stall regime have been identified. This paper presents preliminary results of this simulation study and discusses key issues regarding predicted flight dynamics characteristics during extreme upset and loss-of-control flight conditions with different flap configurations.

  4. Reconstructive Surgery for Severe Penile Inadequacy: Phalloplasty with a Free Radial Forearm Flap or a Pedicled Anterolateral Thigh Flap

    Directory of Open Access Journals (Sweden)

    N. Lumen

    2008-01-01

    Full Text Available Objectives. Severe penile inadequacy in adolescents is rare. Phallic reconstruction to treat this devastating condition is a major challenge to the reconstructive surgeon. Phallic reconstruction using the free radial forearm flap (RFF or the pedicled anterolateral thigh flap (ALTF has been routinely used in female-to-male transsexuals. Recently we started to use these techniques in the treatment of severe penile inadequacy. Methods. Eleven males (age 15 to 42 years were treated with a phallic reconstruction. The RFF is our method of choice; the ALTF is an alternative when a free flap is contraindicated or less desired by the patient. The RFF was used in 7 patients, the ALTF in 4 patients. Mean followup was 25 months (range: 4–49 months. Aesthetic and functional results were evaluated. Results. There were no complications related to the flap. Aesthetic results were judged as “good” in 9 patients and “moderate” in 2 patients. Sensitivity in the RFF was superior compared to the ALTF. Four patients developed urinary complications (stricture and/or fistula. Six patients underwent erectile implant surgery. In 2 patients the erectile implant had to be removed due to infection or erosion. Conclusion. In case of severe penile inadequacy due to whatever condition, a phalloplasty is the preferred treatment nowadays. The free radial forearm flap is still the method of choice. The anterolateral thigh flap can be a good alternative, especially when free flaps are contraindicated, but sensitivity is markedly inferior in these flaps.

  5. A Review Of Pectoralis Major Musculocutaneous Island Flap In ...

    African Journals Online (AJOL)

    Like microvascular free flaps, pectoralis major flaps can be transferred in a single stage and have largely replaced deltepectoral (Bakanjiam) flap in head and neck reconstruction. This retrospective study was carried out to highlight the usefulness of this flap in different situations. Ten patients, aged six to 55 years operated ...

  6. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available Background  Robots have allowed head and neck surgeons to extirpate oropharyngealtumors safely without the need for lip-split incision or mandibulotomy. Using robots inoropharyngealreconstruction is newbut essentialfor oropharyngeal defectsthatresultfromrobotic tumor excision. We report our experience with robotic free-flap reconstruction ofhead and neck defectsto exemplify the necessity forrobotic reconstruction.Methods  We investigated head and neck cancer patients who underwent ablation surgeryand free-flap reconstruction by robot. Between July 1, 2011 andMarch 31, 2012, 5 caseswereperformed and patient demographics, location of tumor, pathologic stage, reconstructionmethods, flap size, recipient vessel, necessary pedicle length, and operation time wereinvestigated.Results  Among five free-flap reconstructions, four were radial forearm free flaps and onewas an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and oneflap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flapinsetting and microanastomosis were achieved using a specially manufactured roboticinstrument. The total operation timewas 1,041.0 minutes(range, 814 to 1,132 minutes, andcomplicationsincluding flap necrosis, hematoma, andwound dehiscence did not occur.Conclusions  Thisstudy demonstratesthe clinically applicable use ofrobotsin oropharyngealreconstruction, especially using a free flap. A robot can assist the operator in insettingthe flap at a deep portion of the oropharynx without the need to perform a traditionalmandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methodsand is accepted asthemost up-to-datemethod.

  7. Critical Appraisal of Nasolabial Flap for Reconstruction of Oral Cavity Defects in Cancer Patients

    International Nuclear Information System (INIS)

    Mebed, A.; Hussein, H.A.; Saber, T.Kh.

    2009-01-01

    Purpose: Re-evaluation of nasolabial flap in lip and oral cavity reconstruction and role of each of its variants in reconstructing various intermediate size defects was addressed. Patients and Methods: Case-series study was con-ducted in National Cancer Institute, Cairo University over the period from July 2005 - January 2009 which included 23 patients with clinically T-l N0, T-2 N0 invasive squamous cell carcinoma of buccal mucosa and the vermilion border of the lower lip. Immediately after surgical excision, one stage reconstruction of the defect was done using a type of nasolabial flap. All patients were followed and the median follow-up period was 7.5 month. Results: Twelve patients with the lower lip carcinoma and 11 patients with the carcinoma of buccal mucosa underwent surgical excision under frozen section control. 19 fasciocutaneous nasolabial flap and 4 facial artery musculomucosal flaps were used for reconstruction. Minor wound complications occurred in 2 flaps and one patient required secondary suture. Flap viability was reliable and was not affected by performance of a synchronous neck dissection. Functional results were satisfactory, cosmetic results were good in most of the patients and excellent when facial artery musculomucosal flap was used. Conclusion: The nasolabial flap is a reliable and minimally traumatic local flap for one stage reconstruction of medium size defects in the oral cavity. The abundant blood supply allowed its modification in order to cover larger defects or to obtain better cosmetic results. This versatility makes it more widely used thus minimizing the use of local tongue flaps and split thickness grafts for covering these medium size defects in cases of buccal mucosa cancer or affecting the other lip or commissure in cases of lip cancer. It has a high viability rate, low complication rate; it is quick and easy to perform in addition to its satisfactory functional and cosmetic results.

  8. The Vasodilator Effect of a Cream Containing 10% Menthol and 15% Methyl Salicylate on Random-Pattern Skin Flaps in Rats

    Directory of Open Access Journals (Sweden)

    Utku Can Dölen

    2015-11-01

    Full Text Available BackgroundIt is still difficult to prevent partial or full-thickness flap necrosis. In this study, the effects of a cream containing menthol and methyl salicylate on the viability of randompattern skin flaps were studied.MethodsForty female Sprague-Dawley rats were divided into two equal groups. Caudally based dorsal random-pattern skin flaps were elevated, including the panniculus carnosus. In the study group, 1.5 mL of a cream containing menthol and methyl salicylate was applied to the skin of the flap, and saline solution (0.9% was used in the control group. Upon completion of the experiment, flap necrosis was analyzed with imaging software and radionuclide scintigraphy. Histopathological measurements were made of the percentage of viable flaps, the number of vessels, and the width of the panniculus carnosus muscle.ResultsAccording to the photographic analysis, the mean viable flap surface area in the study group was larger than that in the control group (P=0.004. According to the scintigrams, no change in radioactivity uptake was seen in the study group (P>0.05. However, a significant decrease was observed in the control group (P=0.006. No statistically significant differences were observed between the groups in terms of the percentage of viable flaps, the number of vessels, or the width of the panniculus carnosus muscle (P>0.05.ConclusionsBased on these results, it is certain that the cream did not reduce the viability of the flaps. Due to its vasodilatory effect, it can be used as a component of the dressing in reconstructive operations where skin perfusion is compromised.

  9. Revisit of Nasolabial flap in the reconstruction of defects involving ...

    African Journals Online (AJOL)

    Conclusion: Data from this study suggest that NL flap is a reliable option for reconstruction of the oral floor, in form as well as function, without esthetic compromise and has a major role even in this era of free flaps. Keywords: Floor of mouth defects, local flaps, nasolabail flap, oral cavity defects, reconstruction, regional flaps ...

  10. Flapping and flexible wings for biological and micro air vehicles

    Science.gov (United States)

    Shyy, Wei; Berg, Mats; Ljungqvist, Daniel

    1999-07-01

    Micro air vehicles (MAVs) with wing spans of 15 cm or less, and flight speed of 30-60 kph are of interest for military and civilian applications. There are two prominent features of MAV flight: (i) low Reynolds number (10 4-10 5), resulting in unfavorable aerodynamic conditions to support controlled flight, and (ii) small physical dimensions, resulting in certain favorable scaling characteristics including structural strength, reduced stall speed, and low inertia. Based on observations of biological flight vehicles, it appears that wing motion and flexible airfoils are two key attributes for flight at low Reynolds number. The small size of MAVs corresponds in nature to small birds, which do not glide like large birds, but instead flap with considerable change of wing shape during a single flapping cycle. With flapping and flexible wings, birds overcome the deteriorating aerodynamic performance under steady flow conditions by employing unsteady mechanisms. In this article, we review both biological and aeronautical literatures to present salient features relevant to MAVs. We first summarize scaling laws of biological and micro air vehicles involving wing span, wing loading, vehicle mass, cruising speed, flapping frequency, and power. Next we discuss kinematics of flapping wings and aerodynamic models for analyzing lift, drag and power. Then we present issues related to low Reynolds number flows and airfoil shape selection. Recent work on flexible structures capable of adjusting the airfoil shape in response to freestream variations is also discussed.

  11. Simulation of Moving Trailing Edge Flaps on a Wind Turbine Blade using a Navier-Stokes based Immersed Boundary Method

    DEFF Research Database (Denmark)

    Behrens, Tim

    . Simulations demonstrated the feasibility and robustness of the approach. The hybrid immersed boundary approach proved to be able to handle 3D airfoil sections with span-wise flap gaps. The flow around and in the wake of a deflected flap at a Reynolds number of 1.63mio was investigated for steady inflow......As the rotor diameter of wind turbines increases, turbine blades with distributed aerodynamic control surfaces promise significant load reductions. Therefore, they are coming into focus in relation to research in academia and industry. Trailing edge flaps are of particular interest in terms...... conditions. A control for two span-wise independent flaps was implemented and first load reductions could be achieved. The hybrid method has demonstrated to be a versatile tool in the research of moving trailing edge flaps. The results shall serve as the basis for future investigations of the unsteady flow...

  12. Temporalis myo-osseous flap: an experimental study

    International Nuclear Information System (INIS)

    Antonyshyn, O.; Colcleugh, R.G.; Hurst, L.N.; Anderson, C.

    1986-01-01

    The present paper investigates the anatomy and vascularization of the temporalis myo-osseous flap. This is a calvarial bone flap that employs temporalis muscle and its distal pericranial extension as a pedicle. In six human cadavers the flap was raised as an island on the anterior deep temporal artery after transecting the zygomatic arch and coronoid process. Maximal mobilization was thus obtained, allowing rotation of the flap into the mouth for intraoral reconstruction. The arc of rotation and potential surgical applications were noted. A comparative study of the temporalis myo-osseous flap and free calvarial bone graft was then conducted in a rabbit model. Vascularization of the calvarial bone flap was confirmed by technetium scintigraphy performed on the first postoperative day. The uptake of fluorochrome labels immediately after transfer verified the adequacy of the periosteal circulation in maintaining viability and new osteoid formation throughout the full thickness of calvarial bone. The transplantation of free calvarial bone grafts was followed by necrosis of most cellular elements. This was demonstrated by an absence of fluorochrome uptake up to 19 days postoperatively and a predominance of empty lacunae and nonviable marrow

  13. Adipofascial Anterolateral Thigh Flap Safety: Applications and Complications

    Directory of Open Access Journals (Sweden)

    Tommaso Agostini

    2013-03-01

    Full Text Available BackgroundA thinned anterolateral thigh (ALT flap is often harvested to achieve optimal skin resurfacing. Several techniques have been described to thin an ALT flap including an adipocutaneous flap, an adipofascial flap and delayed debulking.MethodsBy systematically reviewing all of the available literature in English and French, the present manuscript attempts to identify the common surgical indications, complications and donor site morbidity of the adipofascial variant of the ALT flap. The studies were identified by performing a systematic search on Medline, Ovid, EMBASE, the Cochrane Database of Systematic Reviews, Current Contents, PubMed, Google, and Google Scholar.ResultsThe study selection process was adapted from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, and 15 articles were identified using the study inclusion criteria. These articles were then reviewed for author name(s, year of publication, flap dimensions and thickness following defatting, perforator type, type of transfer, complications, thinning technique, number of cases with a particular area of application and donor site morbidity.ConclusionsThe adipofascial variant of the ALT flap provides tissue to fill large defects and improve pliability. Its strong and safe blood supply permits adequate immediate or delayed debulking without vascular complications. The presence of the deep fascia makes it possible to prevent sagging by suspending and fixing the flap for functional reconstructive purposes (e.g., the intraoral cavity. Donor site morbidity is minimal, and thigh deformities can be reduced through immediate direct closure or liposuction and direct closure. A safe blood supply was confirmed by the rate of secondary flap debulking.

  14. Reconstruction of eyelids with Washio flap in anophthalmia.

    Science.gov (United States)

    Tvrdek, M; Kozák, J

    2014-01-01

    The authors present a case report of a patient with anophthalmia in whom retroauriculo-temporal flap (Washio flap) was used for reconstruction of eyelids. This flap, which is mostly used for reconstructions of nasal defects, was not used in this way according to available literature.

  15. Reconstruction of cica-contracture on the face and neck with skin flap and expanded skin flap pedicled by anterior branch of transverse cervical artery.

    Science.gov (United States)

    Chen, Baoguo; Song, Huifeng; Xu, Minghuo; Gao, Quanwen

    2016-09-01

    A high-quality flap is necessary for repairing faciocervical scar contractures. The supraclavicular region and chest wall are the preferred choices for reconstruction. The supraclavicular island flap (SIF) pedicled by the transverse cervical artery (TCA) has been reported. Compared to the traditional SIF flap, another type of flap pedicled by the anterior perforator of transverse cervical artery (ap-TCA) is more convenient for transfer to the faciocervical area. In this article, we use this type of perforator flap and expanded perforator flap to repair the faciocervical contracture. In this study, 10 cases (deformity caused by burn or trauma to the face and neck sites) with an average age of 32 years-old, were treated by ap-TCA flap and this type of expanded flap. In between, the flap was pre-expanded for approximately 3 months prior to transfer in 6 patients. Another 4 cases did not want the expander because of the long duration required for saline filling and potential complications of the expander. Bilateral prefabricated flaps were designed in two female cases. All 12 flaps in 10 patients were transferred tension-free to the defects and no flap was lost. The size of the flap ranged from 12 cm × 8 cm to 15 cm × 20 cm. All 12 flaps survived completely. The donor sites were closed directly in the above 6 patients where an expander had been used and reconstructed by split skin graft in 4 patients where no expander had been employed. Through a mean time of 6 months' follow-up, only one female patient was disappointed with the cicatrix that presented on the upper polar skin of both breasts, the other 9 patients were satisfied with both recipient function and appearance. The color and the texture matched well with the recipient area. The ap-TCA flap and expanded ap-TCA flap can be considered reliable options for faciocervical deformities as it can be easily elevated and it matches well with faciocervical area in color. With regards to the expanded flap, we

  16. Risk factors leading to mucoperiosteal flap necrosis after primary palatoplasty in patents with cleft palate.

    Science.gov (United States)

    Rossell-Perry, Percy; Figallo-Hudtwalcker, Olga; Vargas-Chanduvi, Roberto; Calderon-Ayvar, Yvette; Romero-Narvaez, Carolina

    2017-10-01

    Few studies have been published reporting risk factors for flap necrosis after primary palatoplasty in patients with cleft palate. This complication is rare, and the event is a disaster for both the patient and the surgeon. This study was performed to explore the associations between different risk factors and the development of flap necrosis after primary palatoplasty in patients with cleft palate. This is a case-control study. A 20 years retrospective analysis (1994-2015) of patients with nonsyndromic cleft palate was identified from medical records and screening day registries). Demographical and risk factor data were collected using a patient´s report, including information about age at surgery, gender, cleft palate type, and degree of severity. Odds ratios and 95% confident intervals were derived from logistic regression analysis. All cases with diagnoses of flap necrosis after primary palatoplasty were included in the study (48 patients) and 156 controls were considered. In multivariate analysis, female sex, age (older than 15 years), cleft type (bilateral and incomplete), and severe cleft palate index were associated with significantly increased risk for flap necrosis. The findings suggest that female sex, older age, cleft type (bilateral and incomplete), and severe cleft palatal index may be associated with the development of flap necrosis after primary palatoplasty in patients with cleft palate.

  17. Flexible wings in flapping flight

    Science.gov (United States)

    Moret, Lionel; Thiria, Benjamin; Zhang, Jun

    2007-11-01

    We study the effect of passive pitching and flexible deflection of wings on the forward flapping flight. The wings are flapped vertically in water and are allowed to move freely horizontally. The forward speed is chosen by the flapping wing itself by balance of drag and thrust. We show, that by allowing the wing to passively pitch or by adding a flexible extension at its trailing edge, the forward speed is significantly increased. Detailed measurements of wing deflection and passive pitching, together with flow visualization, are used to explain our observations. The advantage of having a wing with finite rigidity/flexibility is discussed as we compare the current results with our biological inspirations such as birds and fish.

  18. Getting Started with PEAs-Based Flapping-Wing Mechanisms for Micro Aerial Systems

    Directory of Open Access Journals (Sweden)

    José Carlos Durán Hernández

    2016-05-01

    Full Text Available This paper introduces recent advances on flapping-wing Micro and Nano Aerial Vehicles (MAVs and NAVs based on Piezoelectric Actuators (PEA. Therefore, this work provides essential information to address the development of such bio-inspired aerial robots. PEA are commonly used in micro-robotics and precise positioning applications (e.g., micro-positioning and micro-manipulation, whereas within the Unmanned Aerial Vehicles (UAVs domain, motors are the classical actuators used for rotary or fixed-wing configurations. Therefore, we consider it pertinent to provide essential information regarding the modeling and control of piezoelectric cantilever actuators to accelerate early design and development stages of aerial microrobots based on flapping-wing systems. In addition, the equations describing the aerodynamic behavior of a flapping-wing configuration are presented.

  19. Simulation-based rhomboid flap skills training during medical education: comparing low- and high-fidelity bench models.

    Science.gov (United States)

    Denadai, Rafael; Saad-Hossne, Rogerio; Raposo-Amaral, Cassio Eduardo

    2014-11-01

    To assess if the bench model fidelity interferes in the acquisition of rhomboid flap skills by medical students. Sixty novice medical students were randomly assigned to 5 practice conditions with instructor-directed Limberg rhomboid flap skills training: didactic materials (control group 1), low-fidelity rubberized line (group 2) or ethylene-vinyl acetate (group 3) bench models; high-fidelity chicken leg skin (group 4) or pig foot skin (group 5) bench models. Pretests and posttests were applied, and Global Rating Scale, effect size, and self-perceived confidence were used to evaluate all flap performances. Medical students from groups 2 to 5 showed better flap performances based on the Global Rating Scale (all P 0.05). The magnitude of the effect was considered large (>0.80) in all measurements. There was acquisition of rhomboid flap skills regardless of bench model fidelity.

  20. Comparison of 5468 retreatments after laser in situ keratomileusis by lifting the flap or performing photorefractive keratectomy on the flap.

    Science.gov (United States)

    Ortega-Usobiaga, J; Llovet-Osuna, F; Katz, T; Djodeyre, M R; Druchkiv, V; Bilbao-Calabuig, R; Baviera, J

    2018-02-01

    To assess visual outcomes of retreatment after laser in situ keratomileusis (LASIK) by lifting the flap or performing photorefractive keratectomy (PRK) on the flap, as well as to establish whether there was an increased risk of epithelial ingrowth (EIG) when LASIK and lifting of the flap are separated by a long time interval and to determine the incidence of corneal haze after PRK. Retrospective study of 4077 patients (5468 eyes) who underwent LASIK and subsequent retreatment were reviewed in order to study their visual results and identify cases of EIG and corneal haze. Enhancements included 5196 eyes from 3876 patients that were retreated by lifting the flap, and 272 eyes from 201 patients that were retreated by PRK on the flap. No statistically significant differences were found between the retreatments in terms of predictability, efficacy, and safety. A total of 704 cases of EIG were found after lifting the flap, for which surgical cleansing was necessary in 70. Surgical cleansing decreased the efficacy index when compared with patients with EIG who did not need cleansing (P=.01). Differences in terms of safety and predictability were not statistically significant. The incidence of corneal haze after ablation of the surface of the previous flap was 14.34%, although none of these cases were clinically relevant. Visual outcomes were similar between patients who were retreated by lifting the flap and those who underwent PRK. The incidence of EIG when the flap was lifted was 13.55%. The incidence of EIG increases with the time elapsed between the primary procedure and retreatment. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Soft Palate Reconstruction Using Bilateral Palatal Mucomuscular Flap and Pharyngeal Flap after Resection of Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Jun Sik Kim

    2012-11-01

    Full Text Available Squamous cell carcinoma infrequently occurs at the soft palate. Although various methodscan be used for reconstruction of soft palate defects that occur after resecting squamous cellcarcinoma, it is difficult to obtain satisfactory results from the perspective of the functionalrestoration of the soft palate. A combination of bilateral palatal mucomuscular flap for theoral side and superiorly based posterior pharyngeal flap for the nasal side were performed ontwo patients who were diagnosed with squamous cell carcinoma of the soft palate in orderto reconstruct the soft palate defects after surgical resection. After surgery, the patients werefollowed-up for a mean period of 11 months. The flaps were well maintained in both patients.The donor site defects were epithelialized and completely recovered. Additionally, no recurrenceof the primary sites was shown. Slight hyponasality was observed in the voice assessmentsthat were conducted 6 months after surgery. No food regurgitation or aspiration was observedin the swallowing tests. We used a combination of bilateral palatal mucomuscular flap andsuperiorly based posterior pharyngeal flap to reconstruct the soft palate defects that occurredafter resecting the squamous cell carcinomas. We reduced the donor site complications andachieved functionally satisfactory outcomes.

  2. Defining the Role of Free Flaps in Partial Breast Reconstruction.

    Science.gov (United States)

    Smith, Mark L; Molina, Bianca J; Dayan, Erez; Jablonka, Eric M; Okwali, Michelle; Kim, Julie N; Dayan, Joseph H

    2018-03-01

     Free flaps have a well-established role in breast reconstruction after mastectomy; however, their role in partial breast reconstruction remains poorly defined. We reviewed our experience with partial breast reconstruction to better understand indications for free tissue transfer.  A retrospective review was performed of all patients undergoing partial breast reconstruction at our center between February 2009 and October 2015. We evaluated the characteristics of patients who underwent volume displacement procedures versus volume replacement procedures and free versus pedicled flap reconstruction.  There were 78 partial breast reconstructions, with 52 reductions/tissue rearrangements (displacement group) and 26 flaps (replacement group). Bra cup size and body mass index (BMI) were significantly smaller in the replacement group. Fifteen pedicled and 11 free flaps were performed. Most pedicled flaps (80.0%) were used for lateral or upper pole defects. Most free flaps (72.7%) were used for medial and inferior defects or when there was inadequate donor tissue for a pedicled flap. Complications included hematoma, cellulitis, and one aborted pedicled flap.  Free and pedicled flaps are useful for partial breast reconstruction, particularly in breast cancer patients with small breasts undergoing breast-conserving treatment (BCT). Flap selection depends on defect size, location, and donor tissue availability. Medial defects are difficult to reconstruct using pedicled flaps due to arc of rotation and intervening breast tissue. Free tissue transfer can overcome these obstacles. Confirming negative margins before flap reconstruction ensures harvest of adequate volume and avoids later re-operation. Judicious use of free flaps for oncoplastic reconstruction expands the possibility for breast conservation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Medial canthal reconstruction with multiple local flaps

    Directory of Open Access Journals (Sweden)

    Akihiro Ogino

    2018-03-01

    Conclusion: This method is somewhat complicated compared to reconstruction with a single flap, but it is a combination of standard local flaps and is a simple reconstructive procedure. By adding additional resection, the suture line is consistent with the border of the facial unit, so postoperative scarring is inconspicuous. This technique is aesthetically useful because of the continuity of colour and texture resulting from the use of adjacent flaps.

  4. Hybrid immersed boundary method for airfoils with a trailing-edge flap

    DEFF Research Database (Denmark)

    Zhu, Wei Jun; Behrens, Tim; Shen, Wen Zhong

    2013-01-01

    In this paper, a hybrid immersed boundary technique has been developed for simulating turbulent flows past airfoils with moving trailing-edge flaps. Over the main fixed part of the airfoil, the equations are solved using a standard body-fitted finite volume technique, whereas the moving trailing......-edge flap is simulated using the immersed boundary method on a curvilinear mesh. An existing in-house-developed flow solver is employed to solve the incompressible Reynolds-Averaged Navier-Stokes equations together with the k-ω turbulence model. To achieve consistent wall boundary conditions at the immersed...... boundaries the k-ωturbulence model is modified and adapted to the local conditions associated with the immersed boundary method. The obtained results show that the hybrid approach is an efficient and accurate method for solving turbulent flows past airfoils with a trailing-edge flap and that flow control...

  5. The role of tip deflection on the thrust produced by rigid flapping fins

    Science.gov (United States)

    Huera-Huarte, Francisco; Gharib, Morteza

    2015-11-01

    It is well known that flexibility plays an important role in the propulsion performance and efficiency of oscillating fin based propulsion systems. Compliance is one of the aspects that has received more attention, as it seems to be a common feature in nature's flyers and swimmers. Active control strategies are also common in nature. We will show how by deflecting only the last 10% of length of a rigid fin, at the tip, the thrust can be changed dramatically. This can be thought as an alternative to passive flexibility for controlling very efficiently the momentum transfer in the wake and therefore the thrust generation when flapping. A series of experiments have been carried with a robotic fin that allowed the control of its flapping kinematics as well as the control of the motions of its tip independently. We will be showing situations in which the tip was kept at a certain fixed position during a power stroke, and others in which it moved either in-phase or out-of-phase with the fin. The observed thrust and wake dynamics will be discussed for all these situations. The authors would like to acknowledge the financial support provided by the Gordon and Betty Moore Foundation and by the Spanish Ministerio de Economia y competitividad (MINECO) through grant DPI2012-37904. Visiting Associate in Aerospace, California Institute of Technology.

  6. Accuracy of Visual Estimation of LASIK Flap Thickness.

    Science.gov (United States)

    Brenner, Jason E; Fadlallah, Ali; Hatch, Kathryn M; Choi, Catherine; Sayegh, Rony R; Kouyoumjian, Paul; Wu, Simon; Frangieh, George T; Melki, Samir A

    2017-11-01

    To assess the accuracy of surgeons' visual estimation of LASIK flap thickness when created by a femtosecond laser by comparing it to ultrasound measurements. Surgeons were asked to visually estimate the thickness of a femtosecond flap during the procedure. Total corneal thickness was measured by ultrasound pachymetry prior to the procedure and the stromal bed was similarly measured after flap lifting. The estimates from three experienced surgeons (cornea fellowship trained and more than 5 years in practice) were compared to those of three cornea fellows, with each surgeon evaluating 20 eyes (120 total). Surgeons were not told the thickness of the flaps unless required for safety reasons. The average difference between visual and ultrasonic estimation of LASIK flap thickness was 15.20 μm. The flap was 10 μm thicker than estimated in 37% of eyes, 20 μm thicker in 17% of eyes, and 30 μm thicker in 10% of eyes. The largest deviation was 53 μm. There was no statistically significant difference between the accuracy of experienced surgeons and fellows (P = .51). There are significant differences between surgeons' visual estimates and ultrasonic measurements of LASIK flap thickness. Relying on these visual estimates may lead to deeper excimer laser ablation than intended. This could lead to thinner residual stromal beds and higher percent tissue altered than planned. The authors recommend that surgeons measure flaps intraoperatively to maximize accuracy and safety. [J Refract Surg. 2017;33(11):765-767.]. Copyright 2017, SLACK Incorporated.

  7. [Analysis of sequelae of the latissimus dorsi flap removal. Report of 44 cases reviewed and tested].

    Science.gov (United States)

    Legré, R; Boghossian, V; Servant, J M; Magalon, G; Bureau, H

    1990-01-01

    Since Tanzini, the latissimus dorsi muscle flap has been widely used in plastic surgery. Based on the experience of two plastic surgery units, we decided to try to define the sequelae of this operation. In order to simplify our analysis we only considered free flaps. Out study is based on 42 patients (26 pure muscular flaps and 16 musculo-cutaneous flaps). The sequelae were analysed in terms of aesthetic and functional criteria. The aesthetic sequelae appeared to be minima in the case of pure muscular flaps, but more severe in the case of musculo-cutaneous flaps. Functional sequelae in the shoulder were observed on muscle testing in 30% of cases, although there were no repercussions on sport or work activities. Analysis of spinal posture demonstrated a modification in the frontal plane in 40% of cases although this could not be clearly attributed to the donor site. On the basis of this study, we can conclude that the latissimus dorsi flap retains an important place in the therapeutic arsenal of plastic surgery due to its reliability and its minor cicatricial and functional sequelae at the donor site.

  8. Routine closure of the donor site with a second dorsal metacarpal artery flap to avoid the use of a skin graft after harvest of a first dorsal metacarpal artery flap.

    Science.gov (United States)

    Chi, Zhenglin; Lin, Damu; Chen, Yiheng; Xue, Jixin; Li, Shi; Chu, Tinggang; Li, Zhijie

    2018-06-01

    Closure of the donor site on the index finger after raising a first dorsal metacarpal artery (DMA) flap harvest is challenging. The conventional choice is to use a full-thickness skin graft. However, this procedure is associated with several complications and a second donor site to harvest the skin graft is inevitable. The aim of this study was to design a modified incision to allow harvest of a first DMA flap without skin graft. From 2015 to 2016, 18 patients with a soft tissue defect of the thumb had reconstruction of the defect using a first DMA flap. A modified incision was used and a relaying perforator flap pedicled on the second DMA was raised through the same incision to cover the donor site. Patient satisfaction, appearance of the injured hand, and the active range of motion (ROM) were assessed. The sensitivity was evaluated by the 2-point discrimination (2-PD) test. All flaps survived completely without complications. Good coverage was obtained with only one linear scar in the dorsum of the hand and no skin grafts. All patients recovered full range of movement in their fingers and regained sensitivity of the flaps. All patients were satisfied with their hand function according to the Michigan Hand Outcomes Questionnaire (MHQ). The mean cosmetic score for the appearance of the injured hand was 8.2 out of 10. Using our modified incision, it was possible to harvest a second DMA flap at the same time as a first DMA flap allowing simultaneous coverage of the donor defect on the index finger. This prevented the need for a skin graft with all of the associated disadvantages. Copyright © 2018. Published by Elsevier Ltd.

  9. Dynamic properties of blood flow and leukocyte mobilization in infected flaps

    International Nuclear Information System (INIS)

    Feng, L.J.; Price, D.C.; Mathes, S.J.; Hohn, D.

    1990-01-01

    Two aspects of the inflammatory response to infection--blood flow alteration and leukocyte mobilization--are investigated in the canine model. The elevation of paired musculocutaneous (MC) and random pattern (RP) flaps allowed comparison of healing flaps with significant differences in blood flow (lower in random pattern flaps) and resistance to infection (greater in musculocutaneous flaps). Blood flow changes as determined by radioactive xenon washout were compared in normal skin and distal flap skin both after elevation and following bacterial inoculation. Simultaneous use of In-111 labeled leukocytes allowed determination of leukocyte mobilization and subsequent localization in response to flap infection. Blood flow significantly improved in the musculocutaneous flap in response to infection. Although total leukocyte mobilization in the random pattern flap was greater, the leukocytes in the musculocutaneous flap were localized around the site of bacterial inoculation within the dermis. Differences in the dynamic blood flow and leukocyte mobilization may, in part, explain the greater reliability of musculocutaneous flaps when transposed in the presence of infection

  10. Boomerang flap reconstruction for the breast.

    Science.gov (United States)

    Baumholtz, Michael A; Al-Shunnar, Buthainah M; Dabb, Richard W

    2002-07-01

    The boomerang-shaped latissimus dorsi musculocutaneous flap for breast reconstruction offers a stable platform for breast reconstruction. It allows for maximal aesthetic results with minimal complications. The authors describe a skin paddle to obtain a larger volume than either the traditional elliptical skin paddle or the extended latissimus flap. There are three specific advantages to the boomerang design: large volume, conical shape (often lacking in the traditional skin paddle), and an acceptable donor scar. Thirty-eight flaps were performed. No reconstruction interfered with patient's ongoing oncological regimen. The most common complication was seroma, which is consistent with other latissimus reconstructions.

  11. Active Control of Separation from the Slat Shoulder of a Supercritical Airfoil

    Science.gov (United States)

    Pack, LaTunia G.; Schaeffler, Norman W.; Yao, Chung-Sheng; Seifert, Avi

    2002-01-01

    Active flow control in the form of zero-mass-flux excitation was applied at the slat shoulder of a simplified high-lift airfoil to delay flow separation. The NASA Energy Efficient Transport (EET) supercritical airfoil was equipped with a 15% chord simply hinged leading edge slat and a 25% chord simply hinged trailing edge flap. The cruise configuration data was successfully reproduced, repeating previous experiments. The effects of flap and slat deflection angles on the performance of the airfoil integral parameters were quantified. Detailed flow features were measured as well, in an attempt to identify optimal actuator placement. The measurements included: steady and unsteady model and tunnel wall pressures, wake surveys, arrays of surface hot-films, flow visualization and Particle Image Velocimetry (PIV). High frequency periodic excitation was applied to delay the occurrence of slat stall and improve the maximum lift by 10 to 15%. Low frequency amplitude modulation was used to reduce the oscillatory momentum coefficient by roughly 50% with similar aerodynamic performance.

  12. Shape optimisation and performance analysis of flapping wings

    KAUST Repository

    Ghommem, Mehdi

    2012-09-04

    In this paper, shape optimisation of flapping wings in forward flight is considered. This analysis is performed by combining a local gradient-based optimizer with the unsteady vortex lattice method (UVLM). Although the UVLM applies only to incompressible, inviscid flows where the separation lines are known a priori, Persson et al. [1] showed through a detailed comparison between UVLM and higher-fidelity computational fluid dynamics methods for flapping flight that the UVLM schemes produce accurate results for attached flow cases and even remain trend-relevant in the presence of flow separation. As such, they recommended the use of an aerodynamic model based on UVLM to perform preliminary design studies of flapping wing vehicles Unlike standard computational fluid dynamics schemes, this method requires meshing of the wing surface only and not of the whole flow domain [2]. From the design or optimisation perspective taken in our work, it is fairly common (and sometimes entirely necessary, as a result of the excessive computational cost of the highest fidelity tools such as Navier-Stokes solvers) to rely upon such a moderate level of modelling fidelity to traverse the design space in an economical manner. The objective of the work, described in this paper, is to identify a set of optimised shapes that maximise the propulsive efficiency, defined as the ratio of the propulsive power over the aerodynamic power, under lift, thrust, and area constraints. The shape of the wings is modelled using B-splines, a technology used in the computer-aided design (CAD) field for decades. This basis can be used to smoothly discretize wing shapes with few degrees of freedom, referred to as control points. The locations of the control points constitute the design variables. The results suggest that changing the shape yields significant improvement in the performance of the flapping wings. The optimisation pushes the design to "bird-like" shapes with substantial increase in the time

  13. Wavefront aberrometry and refractive outcomes of flap amputation after LASIK

    NARCIS (Netherlands)

    Al Saady, Rana L.; van der Meulen, Ivanka J.; Nieuwendaal, Carla P.; Engelbrecht, Leonore A.; Mourits, Maarten P.; Lapid-Gortzak, Ruth

    2014-01-01

    Laser in situ keratomileusis flap amputation was performed in 3 eyes of 2 patients because of flap melt and surface irregularity. In the first patient, a 34-year-old man, flaps were excised after a photorefractive keratectomy retreatment procedure on a previous LASIK flap had been done, secondary to

  14. The effect of topical apraclonidine on subconjunctival hemorrhage and flap adherence in LASIK patients.

    Science.gov (United States)

    Aslanides, loannis M; Tsiklis, Nikolaos S; Ozkilic, Efekan; Coskunseven, Efekan; Pallikaris, loannis G; Jankov, Mirko R

    2006-06-01

    To determine whether the use of topical apraclonidine just before the LASIK procedure prevents subconjunctival hemorrhage and to study its effect on postoperative flap adherence. Topical apraclonidine 0.125% was randomly applied to 1 eye of 66 myopic patients who underwent primary bilateral LASIK. Apraclonidine was instilled 1 hour prior to and 30 seconds before placing the vacuum ring of the microkeratome, whereas the other eye served as control. Thirty minutes after the operation, all patients were examined by the surgeon to evaluate hyperemia and identify flap-related complications (eg, slippage, dislocation, or flap folds). The size of subconjunctival hemorrhage was also evaluated on postoperative days 1 and 7. All 132 eyes in the study were examined after surgery to identify flap folds and/or their dislocation. In the apraclonidine group, 48 (72.8%) eyes had no hyperemia, 16 (24.2%) eyes had mild hyperemia, 2 (3%) eyes had moderate hyperemia, and no (0%) eyes had severe hyperemia. In the control group, 37 (56.1%) eyes had mild hyperemia, 21 (31.8%) eyes had moderate hyperemia, 1 (1.5%) eye had severe hyperemia, and 7 (10.6%) eyes had no hyperemia. In the apraclonidine group, 44 (66.7%) eyes had no subconjunctival hemorrhage (grade 0); grade 1 was present in 19 (28.8%) eyes whereas grades 2 and 3 were present in 2 (3%) eyes and 1 (1.5%) eye, respectively. In the control group, 19 (28.8%) eyes showed grade 0, 13 (19.7%) eyes had grade 1, and grades 2 and 3 were present in 20 (30.3%) eyes and 14 (21.2%) eyes, respectively. Chi-square test showed a highly significant difference between the two groups (P < .001). No flap-related problems were reported in either group. Topical apraclonidine applied before LASIK surgery may prevent immediate postoperative hyperemia and prolonged subconjunctival hemorrhage by its alpha-mimetic vasoconstrictor effect without inducing flap adherence complication.

  15. The Internal Pudendal Artery Perforator Thigh Flap: A New Freestyle Pedicle Flap for the Ischial Region

    Directory of Open Access Journals (Sweden)

    Ichiro Hashimoto, MD

    2014-05-01

    Conclusions: The perforator vessels of the internal pudendal artery are very close to the ischial tuberosity. Blood flow to the flap is reliable when careful debridement of the pressure sore is performed. The iPap thigh flap is a new option for soft-tissue defects in the ischial region, including ischial pressure sores.

  16. The Versatile Extended Thoracodorsal Artery Perforator Flap for Breast Reconstruction

    DEFF Research Database (Denmark)

    Jacobs, Jordan; Børsen-Koch, Mikkel; Gunnarsson, Gudjon L.

    2016-01-01

    complications occurred in 10 of 106 (10%) cases and included hematoma (1/108), venous congestion (2/108), and partial flap necrosis (7/108). The reconstructive goal was achieved in 103 of 106 (97%) flaps. CONCLUSIONS: The TAP flap is a pedicled, fasciocutaneous flap that can be used for total breast...

  17. [Ablation on the undersurface of a LASIK flap. Instrument and method for continuous eye tracking].

    Science.gov (United States)

    Taneri, S; Azar, D T

    2007-02-01

    The risk of iatrogenic keratectasia after laser in situ keratomileusis (LASIK) increases with thinner posterior stromal beds. Ablations on the undersurface of a LASIK flap could only be performed without the guidance of an eye tracker, which may lead to decentration. A new method for laser ablation with flying spot lasers on the undersurface of a LASIK flap was developed that enables the use of an active eye tracker by utilizing a novel instrument. The first clinical results are reported. Patients wishing an enhancement procedure were eligible for a modified repeat LASIK procedure if the flaps cut in the initial procedure were thick enough to perform the intended additional ablation on the undersurface leaving at least 90 microm of flap thickness behind. (1) The horizontal axis and the center of the entrance pupil were marked on the epithelial side of the flap using gentian violet dye. (2) The flap was reflected on a newly designed flap holder which had a donut-shaped black marking. (3) The eye tracker was centered on the mark visible in transparency on the flap. (4) Ablation with a flying spot Bausch & Lomb Technolas 217z laser was performed on the undersurface of the flap with a superior hinge taking into account that in astigmatic ablations the cylinder axis had to be mirrored according to the formula: axis on the undersurface=180 degrees -axis on the stromal bed. (5) The flap was repositioned. Detection of the marking on the modified flap holder and continuous tracking instead of the real pupil was possible in all of the 12 eyes treated with this technique. It may be necessary to cover the real pupil during ablation in order not to confuse the eye tracker. Ablation could be performed without decentration or loss of best spectacle-corrected visual acuity. Refractive results in minor corrections were good without nomogram adjustment. Using this novel flap holder with a marking that is tracked instead of the real pupil, centered ablations with a flying spot laser

  18. On the numerical simulation of flutter and its suppression by active control

    International Nuclear Information System (INIS)

    Dong, B.; Mook, D.T.

    1994-01-01

    The classic problem of predicting the motion (flutter) of a rigid airfoil mounted on an elastic support in a steady freestream is revisited. In the classic approach, the equations of motion were linearized, the supports were linear springs, the motion was assumed to be periodic, the aerodynamic loads were predicted by Wagner's function, and the solution was obtained in the so-called frequency domain. In the present approach, the equations of motion are in their fully nonlinear form, the supports may be nonlinear springs, the motion is not assumed to be periodic, the loads are predicted by a general unsteady vorticity-panel method, and the solution is obtained in the so-called time domain. After it is demonstrated that the present approach predicts the onset of flutter and the post-flutter behavior for flat-plate as well as thick airfoils, the airfoil -is modified by the addition of a flap at the trailing edge. The flap is part of an actively controlled servomechanism, and it is demonstrated that flutter can be readily controlled with very little effort by a variety of feedback-control laws. In the present approach, emphasis is placed on considering the airfoil, its supports, the flowing air and the control/servo mechanism collectively to be a single dynamic system. All the equations of motion and control laws are solved simultaneously and interactively; thus, complete interactions among the various subsystems are captured. The present simulation of an oscillating airfoil provides some characteristics of the flutter phenomenon that were missed in previous studies: for example, it is shown that, in the absence of flaps, the motion in heave (the translational part of the motion) is responsible for adding energy to (exciting) the structural subsystem while the motion in pitch is responsible for extracting energy from (damping) the structural subsystem. Below the critical speed, there is more dissipation than excitation and hence all initial disturbances decay

  19. Reconstruction of radionecrotic ulcer using a myocutaneous flap

    International Nuclear Information System (INIS)

    Takahashi, Hiroyuki; Okano, Shinji; Iwasaki, Yasumasa; Mori, Tamotsu; Miyamoto, Yoshihiro; Shigeki, Sadayuki

    1990-01-01

    Problems in the surgical treatment of radionecrotic ulcers, using a myocutaneous flap, have been reviewed in 21 patients. These problems included poor wound healing, radiation damage to important nerves and vessels there by making dissection difficult, malignant changes, infections, continuing necrosis of the tissue, and bleeding during surgery and secondary hemorrhaging. The use of a myocutaneous flap has many advantages when compared with conventional flaps and free skin grafts in the reconstruction of radionecrotic ulcers. Flap survival was good, but an incomplete excision of the ulcer delayed primary wound healing. Therefore, complete excision of the radionecrotic ulcer is imperative. (author)

  20. Island Latissimus Dorsi Muscle Flap and a Perforator Flap in Repairing Post-Gunshot Thoracic Spine CSF Fistula: Case Presentation

    Directory of Open Access Journals (Sweden)

    Nangole F. Wanjala

    2015-01-01

    Full Text Available Persistent posttraumatic CSF fluid leakage may present a challenge to manage. Failure to address the leakage may result in complications such as meningitis, septicemia, radiculopathy, muscle weakness, and back pains. While the majority of the leakages may be managed conservatively, large dura defects as a result of gunshot wounds or motor vehicle accidents are best managed by surgical interventions. This may range from primary closure of the defect to fascial grafts, adhesive glues, and flaps. We present our experience with the use of flaps in a patient who had sustained such wounds in the thoracic spine. An island latissimus dorsal flap and a perforator fasciocutaneous flap were used to close the defect. Postoperatively the patient recovered well and the wounds healed without any complications.

  1. [Repair of pressure sores over ischial tuberosity with long head of biceps femoris muscle flap combined with semi-V posterior thigh fasciocutaneous flap].

    Science.gov (United States)

    Hai, Heng-lin; Shen, Chuan-an; Chai, Jia-ke; Li, Hua-tao

    2012-02-01

    To explore the clinical effect of transplantation of the long head of biceps femoris muscle flap in combination with semi-V posterior thigh fasciocutaneous flap for repair of pressure sores over ischial tuberosity. Eight patients with 10 deep pressure sores over ischial tuberosity were admitted to the First Affiliated Hospital to the PLA General Hospital and the 98th Hospital of PLA from April 2004 to June 2010. The wounds measured from 2 cm × 2 cm to 6 cm × 4 cm were covered with the long head of biceps femoris muscle flap and semi-V posterior thigh fasciocutaneous flap (ranged from 10 cm × 6 cm to 13 cm × 8 cm). The condition of flaps was observed and followed up for a long time. All flaps survived. Nine wounds healed by first intention. Subcutaneous accumulation of fluids occurred in one wound with formation of a sinus at drainage site, and it healed after dressing change for 25 days. Patients were followed up for 7 to 34 months. Sore recurred in one patient 9 months after surgery, and it was successfully repaired with the same flap for the second time. Flaps in the other 7 patients appeared satisfactory with soft texture and without ulceration. This combined flap is easy in formation and transfer, and it causes little side injury with good resistance against pressure. It is a new method for repair of pressure sore over sacral region.

  2. Fascioperichondrial Flap with a Proximal Base Combined with Prominent Ear Surgery

    Directory of Open Access Journals (Sweden)

    Heval Selman Özkan

    2017-08-01

    Full Text Available Objective: In this article, we present a personalized surgical technique to relocate a fascioperichondrial flap with a proximal base as an additional measure to improve results and hide sharp edges which frequently occur following traditional otoplasty. Materials and Methods: Fascioperichondrial flap with a proximal base prepared from the dorsal side was transposed to the anterior helix and conchal excision side and secured with stitches to hide visible edges and reinforce Furnas sutures. Nine patients operated for prominent ear deformity using this modification were included in the study and follow-up period was at least 6 months. Conchal mastoid distances were calculated from the superior and middle third of the ears before and after the operation, also in follow-up controls to determine the efficiency of the method. Results: There were no suture extrusions, skin necrosis or infection. The mean difference for both the upper and middle third of the ears were considerably lower (p≤0.05 at the end of six month after the operation. There were no visible skin edges and discomfort described by the patients. Conclusion: Fascioperichondrial flap with a proximal base repositioning to conchal side is an easy procedure that can be applied simply as an adjunct to traditional techniques. Addition of this flap provides an additional tissue to reinforce suture repair and, the results seem to be more durable and strong. Another main advantage of this flap is eliminating the unnatural visible breakpoints in the conchal bowl.

  3. Aerodynamic efficiency of a bio-inspired flapping wing rotor at low Reynolds number

    OpenAIRE

    Li, Hao; Guo, Shijun

    2018-01-01

    This study investigates the aerodynamic efficiency of a bioinspired flapping wing rotor kinematics which combines an active vertical flapping motion and a passive horizontal rotation induced by aerodynamic thrust. The aerodynamic efficiencies for producing both vertical lift and horizontal thrust of the wing are obtained using a quasi-steady aerodynamic model and two-dimensional (2D) CFD analysis at Reynolds number of 2500. The calculated efficiency data show that both efficiencies (propulsiv...

  4. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK).

    Science.gov (United States)

    Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen

    2017-01-01

    Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of -0.75 D to 1.0 D ×175° in her right eye 1 month later. We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management.

  5. An Elongated Leading Edge Facilitates Rotation Flap Closure: In Vivo Demonstration.

    Science.gov (United States)

    Lichon, Vanessa; Barbosa, Naiara; Gomez, Doug; Goldman, Glenn

    2016-01-01

    Variation in the design of a rotation flap may affect wound closure tension. Lengthening the leading edge of a rotation flap has been a method of reducing the tension of closure in the primary motion. An in vitro study negating this tenant has been published. The authors set out to design an in vivo experiment to determine if lengthening the leading edge of a rotation flap has the effect of reducing closure tension in the primary motion of the repair. An animal study approved by Institutional Animal Care and Use Committee was undertaken in a pig model. A tension-measuring apparatus was designed using Teflon-coated wires and digital tensiometers. Rotation flaps of a standard design and with elongated leading edges were incised on the flanks of pigs under general anesthesia. Flap closure tensions were measured at points along the leading edge of the flap and in the secondary motion. Elongating the leading edge of a flap led to a statistically significant reduction in closure tension in the primary motion of the flap and at the flap tip. The secondary motion closure tensions were essentially unaffected. The authors confirm that elongating the leading edge of a standard rotation flap will reduce closure tension in the primary flap motion.

  6. Postirradiation flap infection about the oral cavity

    International Nuclear Information System (INIS)

    Cabbabe, E.B.; Herbold, D.R.; Sunwoo, Y.C.; Baroudi, I.F.

    1983-01-01

    Postirradiation alteration of oral flora is well documented in the literature. Infection as a complication leading to partial or complete loss of a flap used to reconstruct a defect in the oral cavity is a worrisome outcome. We describe how a flap that was judged clinically to be viable became overwhelmingly infected with the Klebsiella oxytoca, an oral cavity pathogen encountered in this patient following irradiation. Local and systemic changes led to detachment of the flap. This complication may be explained, in view of the absence of venous congestion or arterial ischemia both clinically and pathologically, by the proven contamination of the flap by the Klebsiella pathogen. Local factors resulted in lower resistance and subsequent overwhelming infection. Discussion of the case, review of pertinent literature, and proposed solutions are presented

  7. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK

    Directory of Open Access Journals (Sweden)

    Tsai TH

    2017-04-01

    Full Text Available Tsung-Han Tsai,1 Kai-Ling Peng,1 Chien-Jen Lin2 1Department of Ophthalmology, 2Department of Radiology, Chi Mei Medical Center, Tainan, Taiwan Background: Laser in situ keratomileusis (LASIK is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK.Case presentation: A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of −0.75 D to 1.0 D ×175° in her right eye 1 month later.Literature review: We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014.Conclusion: Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could

  8. Formation of vortex pairs with hinged rigid flaps at the nozzle exit

    Science.gov (United States)

    Das, Prashant; Govardhan, Raghuraman; Arakeri, Jaywant

    2013-11-01

    Biological flows related to aquatic propulsion using pulsed jets, or flow through the valves in a human heart, have received considerable attention in the last two decades. Both these flows are associated with starting jets that occur through biological tissue/membranes that are flexible. Motivated by these flows, we explore in the present work, the effect of passive flexibility of the nozzle exit on vortex generation from a starting jet. The starting jet is generated using a two-dimensional piston cylinder mechanism, the cross-section of the cylinder being rectangular with large aspect ratio. The fluid is pushed out of this cylinder or channel using a computer controlled piston. We introduce flexibility at the channel exit by hinging rigid flaps, which are initially parallel to the channel. The hinge used is such that it provides negligible stiffness or damping, thus allowing for the maximum opening of the flaps due to fluid forces. Using this system, we study both the flap kinematics and the vorticity dynamics downstream of the channel exit. Visualizations show large flap motions as the piston starts and this dramatically changes the vorticity distribution downstream of the flaps, with the formation of up to three different kinds of vortex pairs. This idealized configuration opens new opportunities to look at the effect of flexibility in such biological flows.

  9. Polidocanol injection for chemical delay and its effect on the survival of rat dorsal skin flaps.

    Science.gov (United States)

    Menevşe, Gülsüm Tetik; TeomanTellioglu, Ali; Altuntas, Nurgül; Cömert, Ayhan; Tekdemir, Ibrahim

    2014-06-01

    Surgical delay is an invasive method requiring a two-stage surgical procedure. Hence, methods that may serve as an alternative to surgical delay have become the focus of interest of research studies. From a conceptual view, any technique that interrupts the blood flow along the edges of a proposed flap will render the flap ischemic and induce a delay phenomenon. Polidocanol (Aethoxysklerol(®)-Kreussler) was initially used as a local anesthetic. Nowadays, it has been used as a sclerosing agent to treat telangiectasias and varicose veins. The aim of this experimental study was to investigate the effects of polidocanol injected around the periphery of a random flap as a sclerosing agent on flap delay and survival in a random flap model. A preliminary histopathologic study was performed on two rats to evaluate the sclerosing effect and distribution of polidocanol injection. After the preliminary study, the main study was carried out with three groups: group 1: dorsal flap (n = 10); group 2: dorsal flap + surgical delay (n = 10), group 3: dorsal flap + chemical delay (n = 10). Tissue samples obtained from the flap and injection area revealed destruction of intradermal vessels. The area affected with sclerosis was limited to 0.1 cm beyond the injection site. Mean viable flap areas were 52.1 ± 4.38% (44.0-58.2) in group 1, 64.8 ± 8.92% (57.2-89.2) in group 2, and 71.8 ± 5.18% (64.0-84.0) in group 3. A statistically highly significant difference was found between the surgical delay and chemical delay groups versus the group without delay (p injection around the dorsal flap in the rat is a safe and easy method for nonsurgical delay. The results have shown a flap survival benefit that is superior to controls and equivalent to surgical delay. The clinical application of polidocanol, already in clinical practice for occlusal of telangiectasias, for surgical delay appears feasible. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons

  10. Blood Perfusion in Human Eyelid Skin Flaps Examined by Laser Speckle Contrast Imaging-Importance of Flap Length and the Use of Diathermy.

    Science.gov (United States)

    Nguyen, Cu Dinh; Hult, Jenny; Sheikh, Rafi; Tenland, Kajsa; Dahlstrand, Ulf; Lindstedt, Sandra; Malmsjö, Malin

    2017-10-11

    It is well known that blood perfusion is important for the survival of skin flaps. As no study has been conducted to investigate how the blood perfusion in human eyelid skin flaps is affected by the flap length and diathermy, the present study was carried out to investigate these in patients. Fifteen upper eyelids were dissected as part of a blepharoplastic procedure, releasing a 30-mm long piece of skin, while allowing the 5 mm wide distal part of the skin to remain attached, to mimic a skin flap (hereafter called a "skin flap"). Blood perfusion was measured before and after repeated diathermy, using laser speckle contrast imaging. Blood perfusion decreased from the base to the tip of the flap: 5 mm from the base, the perfusion was 69%, at 10 mm it was 40%, at 15 mm it was 20%, and at 20 mm it was only 13% of baseline values. Diathermy further decreased blood perfusion (measured 15 mm from the base) to 13% after applying diathermy for the first time, to 6% after the second and to 4% after the third applications of diathermy. Blood perfusion falls rapidly with distance from the base of skin flaps on the human eyelid, and diathermy reduces blood perfusion even further. Clinically, it may be advised that flaps with a width of 5 mm be no longer than 15 mm (i.e., a width:length ratio of 1:3), and that the use of diathermy should be carefully considered.

  11. "Apron" flap and re-creation of the inframammary fold following TRAM flap breast reconstruction.

    Science.gov (United States)

    Amir, A; Silfen, R; Hauben, D J

    2000-03-01

    To the best of our knowledge, the recreation of an inframammary fold after TRAM flap breast reconstruction has not yet been described. This article offers a technique for the creation of an inframammary fold as a secondary procedure. The technique has been performed thus far in two patients with good aesthetic outcomes and no postoperative complications. It may also be suitable for adding bulk to the TRAM flap, especially in bilateral breast reconstruction, and for other minor chest deformities.

  12. Contralateral lumbo-umbilical flap: A versatile technique for volar finger coverage

    Directory of Open Access Journals (Sweden)

    Akram Hussain Bijli

    2017-01-01

    Full Text Available Background: While contemplating any difficult soft tissue reconstruction, patient comfort and compliance is of paramount importance. Reconstruction of the volar aspect of fingers and hand by the ipsilateral pedicled flaps (groin flap, abdominal flaps is demanding as the flap inset is difficult for the surgeon and very uncomfortable for the patient. This often leads to flap complications. For the comfort of the patient, better compliance and ease of complete inset, we planned to manage soft tissue defects of the volar aspect of fingers and hand by a new contralateral pedicled lumbo-umbilical flap. This flap is based on the paraumbilical perforators of deep inferior epigastric artery. Materials and Methods: The contralateral pedicled lumbo-umbilical flap was used in eight patients with high-tension electrical burn injuries involving the volar aspect of fingers and hand. The patients were closely observed for first 6 weeks for any flap or donor site complications and then followed monthly to assess donor and recipient site characteristics for 6 months to 2 years. Results and Conclusion: Large flaps up to 8 cm × 16 cm were raised. All but one flaps survived completely. All patients were mobilised within 48 h and five were discharged in less than a week after initial inset. The flap is reliable, easy to harvest and easy to inset on the volar aspect of fingers. The arm is positioned in a very comfortable position. The main disadvantage, however, is a conspicuous abdominal scar.

  13. Clinical application of scrotal flap on penis lengthening.

    Science.gov (United States)

    Zhuo, Qinqiang; Li, Shirong; Wu, Julong; Wang, Zhenxiang; Yang, Dongyun; Tao, Ling

    2009-03-01

    To investigate the clinical application of the scrotal flap on penis lengthening. One hundred and fifty-two patients were operated using the scrotal flap from July 1998 to January 2008 at the Department of Plastic and Aesthetic, Surgery Southwest Hospital, Chongqing, China. The procedure consisted of designing a positive sign shaped incision 1.5cm above the root of the penis, dissect and release the superficial suspensory ligament and part of the deep suspensory ligament, then cover the elongated cavernosum with proper scrotal flap. Six-month to 5-year follow-up showed that all patients were satisfied with the good contour and function of the penis. The operation was successful. The method of using scrotal flap on penis lengthening has the following advantages: simple operation, reliable blood supply of the flap, one-stage operation, and satisfactory postoperative results. It is a preferable operation technique for penis lengthening.

  14. Investigation of the maximum load alleviation potential using trailing edge flaps controlled by inflow data

    DEFF Research Database (Denmark)

    Fischer, Andreas; Aagaard Madsen, Helge

    2014-01-01

    The maximum fatigue load reduction potential when using trailing edge flaps on mega-watt wind turbines was explored. For this purpose an ideal feed forward control algorithm using the relative velocity and angle of attack at the blade to control the loads was implemented. The algorithm was applied...... to time series from computations with the aeroelastic code HAWC2 and to measured time series. The fatigue loads could be reduced by 36% in the computations if the in flow sensor was at the same position as the blade load. The decrease of the load reduction potential when the sensor was at a distance from...... the blade load location was investigated. When the algorithm was applied to measured time series a load reduction of 23% was achieved which is still promissing, but significantly lower than the value achieved in computations....

  15. Digital artery perforator (DAP) flaps: modifications for fingertip and finger stump reconstruction.

    Science.gov (United States)

    Mitsunaga, Narushima; Mihara, Makoto; Koshima, Isao; Gonda, Koichi; Takuya, Iida; Kato, Harunosuke; Araki, Jun; Yamamoto, Yushuke; Yuhei, Otaki; Todokoro, Takeshi; Ishikawa, Shoichi; Eri, Uehara; Mundinger, Gerhard S

    2010-08-01

    Various fingertip reconstructions have been reported for situations where microsurgical finger replantation is impossible. One method is the digital artery perforator (DAP) flap. Herein we report 13 DAP flaps for fingertip and finger stump reconstruction following traumatic finger amputations, highlighting modifications to the originally described DAP flap. From October 1998 to December 2007, a total of 13 fingers (11 patients) underwent fingertip and finger stump reconstruction with modified DAP flaps following traumatic finger amputations. We performed six adipocutaneous flaps, three adipose-only flaps, two supercharged flaps and two extended flaps. Flap size ranged from 1.44 to 8 cm(2) (average 3.25 cm(2)). All flaps survived completely with the exception of partial skin necrosis in two cases. One of these cases required debridement and skin grafting. Our initial three cases used donor-site skin grafting. The donor site was closed primarily in the 10 subsequent cases. No patients showed postoperative hypersensitivity of repaired fingertips. Semmes-Weinstein (SW) test result for flaps including a digital nerve branch did not differ from those without (average 4.07 vs. 3.92). Modified DAP flaps allow for preservation of digital length, volume and finger function. They can be raised as adiposal-only flaps or extended flaps and supercharged through perforator-to-perforator anastomoses. The donor defect on the lateral pulp can be closed primarily or by skin grafting. For traumatic fingertip and finger stump reconstructions, DAP flaps deliver consistent aesthetic and functional results. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Biomechanical corneal changes induced by different flap thickness created by femtosecond laser

    Directory of Open Access Journals (Sweden)

    Fabricio W. Medeiros

    2011-01-01

    Full Text Available OBJECTIVE: To evaluate the impact of the creation of corneal flaps at different thicknesses on the biomechanical properties of swine corneas. METHOD: Twelve swine eyes were obtained to form two groups: 100 μm flap thickness and 300 μm flap thickness. Each eye was submitted to the following examinations: raster topography to investigate corneal curvature alterations, ocular response analyzer to investigate corneal hysteresis change, optical coherence tomography to measure central corneal and flap thickness and sonic wave propagation velocity as a measure of stiffness, before and immediately after flap creation. After flap amputation, surface wave velocity measurements were repeated. RESULTS: Measured flap thicknesses were statistically different for thin and thick flap groups, with an average of 108.5 + 6.9 and 307.8 + 11.5 μm respectively. Hysteresis and corneal resistance factor did not change significantly after flap creation in the thin flap group. With thicker flaps, both parameters decreased significantly from 8.0 +1.0 to 5.1 +1.5 mmHg and from 8.2 + 1.6 to 4.1 +2.5 mmHg respectively. Simulated keratometry values increased in the thick flap group (from 39.5 + 1 D to 45.9+1.2 D after flap creation but not in the thin flap group (from 40.6 + 0.6 D to 41.4+ 1.0 D. Regarding surface wave velocity analysis, the surgical procedures induced statistically lower results in some positions. CONCLUSION: In the experimental conditions established by this model, thicker flaps presented a greater biomechanical impact on the cornea.

  17. Bistable flapping of flexible flyers in oscillatory flow

    Science.gov (United States)

    Huang, Yangyang; Kanso, Eva

    2016-11-01

    Biological and bio-inspired flyers move by shape actuation. The direct control of shape variables for locomotory purposes is well studied. Less is known about indirect shape actuation via the fluid medium. Here, we consider a flexible Λ-flyer in oscillatory flow that is free to flap and rotate around its fixed apex. We study its motion in the context of the inviscid vortex sheet model. We first analyze symmetric flapping about the vertical axis of gravity. We find that there is a finite value of the flexibility that maximizes both the flapping amplitude and elastic energy storage. Our results show that rather than resonance, the flyer relies on fluidic effects to optimize these two quantities. We then perturb the flyer away from the vertical and analyze its stability. Four distinct types of rolling behavior are identified: mono-stable, bistable, bistable oscillatory rotations and chaotic dynamics. We categorize these types of behavior in terms of the flyer's and flow parameters. In particular, the transition from mono-stable to bistable behavior occurs at a constant value of the product of the flow amplitude and acceleration. This product can be interpreted as the ratio of fluidic drag to gravity, confirming the fluid role in this transition.

  18. Droplet ejection and sliding on a flapping film

    Directory of Open Access Journals (Sweden)

    Xi Chen

    2017-03-01

    Full Text Available Water recovery and subsequent reuse are required for human consumption as well as industrial, and agriculture applications. Moist air streams, such as cooling tower plumes and fog, represent opportunities for water harvesting. In this work, we investigate a flapping mechanism to increase droplet shedding on thin, hydrophobic films for two vibrational cases (e.g., ± 9 mm and 11 Hz; ± 2 mm and 100 Hz. Two main mechanisms removed water droplets from the flapping film: vibrational-induced coalescence/sliding and droplet ejection from the surface. Vibrations mobilized droplets on the flapping film, increasing the probability of coalescence with neighboring droplets leading to faster droplet growth. Droplet departure sizes of 1–2 mm were observed for flapping films, compared to 3–4 mm on stationary films, which solely relied on gravity for droplet removal. Additionally, flapping films exhibited lower percentage area coverage by water after a few seconds. The second removal mechanism, droplet ejection was analyzed with respect to surface wave formation and inertia. Smaller droplets (e.g., 1-mm diameter were ejected at a higher frequency which is associated with a higher acceleration. Kinetic energy of the water was the largest contributor to energy required to flap the film, and low energy inputs (i.e., 3.3 W/m2 were possible. Additionally, self-flapping films could enable novel water collection and condensation with minimal energy input.

  19. The Versatile Naso-Labial Flaps in Facial Reconstruction

    International Nuclear Information System (INIS)

    El-Marakby, H.H.

    2005-01-01

    Surgical excision of tumors from the face may create a defect that is difficult to restore. Skin grafts can only cover superficial defects and has a natural tendency to contract and may not take properly. Also, because of the colour mismatch, it is not cosmetically identical to the face. The use of regional flaps such as the median forehead flaps are usually bulky, can not cover a wide range of facial reconstruction and usually require the donor area to be grafted. The naso-labial flaps are very useful and versatile local flaps, with robust vascularity that can be readily elevated without a delay. The flap can be superiorly based to reconstruct defects on the cheek, side wall or the dorsum of the nose, alae, collumula and the lower eye lid. Inferiorly based flaps can be used to reconstruct defects in the upper lip, anterior floor of the mouth and the lower lip. The flap can be turned over and used as a lining of the nose and the lip. Aim of the Study: In the current study we present our experience with utilization of the nasolabial flaps in facial reconstruction. We evaluated the indications, flap designs, technique, and complications. We will also assess the final functional and aesthetic results. Material and Methods: The study included 20 patients (12 males and 8 females) presented at the surgical department, National Cancer Institute (NCl) Cairo University with skin cancer at different areas of the face. Preoperative assessment includes. Assessment of the stage of the disease, the flap design and patient general condition. The mean age of the patients was 56.3±6 years (range ]6-62 years). Fifteen patients presented with basal cell carcinoma, 2 squamous cell carcinoma, one malignant melanoma, one keratoacanthoma, and one xeroderma pigmentosa. Nasal defects constituted 75% of cases, the rest were lower eye lid (2), one upper lip and one oral commisure beside a case of cheek reconstruction. There was no major complication; only one patient suffered a reactionary

  20. Scrotal reconstruction with superomedial fasciocutaneous thigh flap

    Directory of Open Access Journals (Sweden)

    DANIEL FRANCISCO MELLO

    2018-02-01

    Full Text Available ABSTRACT Objective: to describe the use of a superomedial fasciocutaneous thigh flap for scrotal reconstruction in open areas secondary to the surgical treatment of perineal necrotizing fasciitis (Fournier’s gangrene. Methods: retrospective analysis of cases treated at the Plastic Surgery Service of Santa Casa de Misericórdia, São Paulo, from 2009 to 2015. Results: fifteen patients underwent scrotal reconstruction using the proposed flap. The mean age was 48.9 years (28 to 66. Skin loss estimates in the scrotal region ranged from 60 to 100%. Definitive reconstruction was performed on average 30.6 days (22 to 44 after the initial surgical treatment. The mean surgical time was 76 minutes (65 to 90 to obtain the flaps, bilateral in all cases. Flap size ranged from 10cm to 13cm in the longitudinal direction and 8cm to 10cm in the cross-sectional direction. The complication rate was 26.6% (four cases, related to the occurrence of segmental and partial dehiscence. Conclusion: the superomedial fasciocutaneous flap of thigh is a reliable and versatile option for the reconstruction of open areas in the scrotal region, showing adequate esthetic and functional results.

  1. Distally based sural neuro-fasciocutaneous perforator flap for foot and ankle reconstruction: Surgical modifications for flap pedicle and donor site closure without skin graft.

    Science.gov (United States)

    Chi, Zhenglin; Chen, Yiheng; Chu, Tinggang; Gao, Weiyang; Li, Zhijie; Yan, Hede; Song, Yonghuan

    2018-02-01

    The conventional procedure of the sural neuro-fasciocutaneous flap enables the supply of blood and venous drainage by increasing the width of the adipofascial tissue and preserving tiny venous return routes. Moreover, skin graft is a common method for donor site closure, which may lead to some complications and influence the aesthetic appearance. We report modifications for a distally based sural neuro-fasciocutaneous perforator flap and a relaying flap for donor site closure without skin graft. Twelve patients undergoing the modified flap for foot and ankle reconstruction were included in this study between 2014 and 2016. A peroneal-based perforator, a superficial vein, and the vascular axis of the sural nerve were included in the pedicle. A Z-shape skin incision was performed to explore the perforator vessels and a relaying island perforator flap was used to close the donor site. All flaps survived completely without necrosis. The area of the flaps ranged from 16 × 8 cm to 30 × 15 cm. The diameter width of the pedicle ranged from 1.0 to 2.0 cm. A relaying perforator island flap was used in 10 cases for donor site closure and no skin graft was performed. There were no serious donor site complications. All patients were satisfied with the aesthetic outcome postoperatively at the final follow-up. The distally based sural neuro-fasciocutaneous perforator flap is considered a reliable method for foot and ankle reconstruction. The modification for flap pedicle and donor site closure method without skin graft should be recommended. Copyright © 2017. Published by Elsevier Ltd.

  2. The Reliability of Pectorals Major Myocutaneous Flap in Head and Neck Reconstruction

    International Nuclear Information System (INIS)

    El-Marakby, H.H.

    2006-01-01

    Background: The pectorals major myocutaneous pedicle flap (PMMPF) has been considered to be the workhorse of pedicled flaps in head and neck reconstruction. Several series of PMMPF procedures in head and neck reconstruction have been reported in the literature. Even with the worldwide use of free flaps, the flap is still considered the mainstay head and neck reconstructive procedures in many centers. However, the flap is usually associated with a high incidence of complications in addition 10 its large bulk compared with the free fasciocutaneous flaps. Also the final functional and the aesthetic results are not comparable to free flaps head and neck reconstruction. Aim of the Study: The aim of the study is to evaluate the reliability of such flap in selected cases of head and neck reconstruction. The indications, technique, complications and the functional as well as the aesthetic results of the flap utilization were evaluated. Patients and Methods: Between May 2002 and May 2005 a 26 consecutive head and neck reconstruction procedures using the PMMPF were carried out on 25 patients at the Department of Surgery, National Cancer Institute, Cairo University. The indications for the flap use were defects due to resection of stage II-IV cancer in the head and neck region. The site, stage of the disease and the presence or absence of distant metastasis were assessed. Also preoperative assessment included the fitness of patients for such an extensive procedure. The total operative time, the need for blood transfusion, the postoperative complications, were all documented. The length of hospital stay, the follow-up of patients as well as the incidence of local recurrence underneath the flap were all evaluated. Results: Pectorals major myocutaneous pedicled flap reconstructions were used to reconstruct defects in the following sites: oral cavity (LO patients); oropharynx/hypopharynx, (5 patients); and neck or face (10 patients). Of the 26 PMMPF reconstructions. 22 flaps were

  3. A prospective, contralateral comparison of photorefractive keratectomy (PRK) versus thin-flap LASIK: assessment of visual function.

    Science.gov (United States)

    Hatch, Bryndon B; Moshirfar, Majid; Ollerton, Andrew J; Sikder, Shameema; Mifflin, Mark D

    2011-01-01

    To compare differences in visual acuity, contrast sensitivity, complications, and higher-order ocular aberrations (HOAs) in eyes with stable myopia undergoing either photo-refractive keratectomy (PRK) or thin-flap laser in situ keratomileusis (LASIK) (intended flap thickness of 90 μm) using the VISX Star S4 CustomVue excimer laser and the IntraLase FS60 femtosecond laser at 1, 3, and 6 months postoperatively. In this prospective, masked, and randomized pilot study, refractive surgery was performed contralaterally on 52 eyes: 26 with PRK and 26 with thin-flap LASIK. Primary outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), contrast sensitivity, and complications. At 6 months, mean values for UDVA (logMAR) were -0.043 ± 0.668 and -0.061 ± 0.099 in the PRK and thin-flap LASIK groups, respectively (n = 25, P = 0.466). UDVA of 20/20 or better was achieved in 96% of eyes undergoing PRK and 92% of eyes undergoing thin-flap LASIK, whereas 20/15 vision or better was achieved in 73% of eyes undergoing PRK and 72% of eyes undergoing thin-flap LASIK (P > 0.600). Significant differences were not found between treatment groups in contrast sensitivity (P ≥ 0.156) or CDVA (P = 0.800) at postoperative 6 months. Types of complications differed between groups, notably 35% of eyes in the thin-flap LASIK group experiencing complications, including microstriae and 2 flap tears. Under well-controlled surgical conditions, PRK and thin-flap LASIK refractive surgeries achieve similar results in visual acuity, contrast sensitivity, and induction of HOAs, with differences in experienced complications.

  4. The lateral crural rein flap: a novel technique for management of tip rotation in primary rhinoplasty.

    Science.gov (United States)

    Kuran, Ismail; Öreroğlu, Ali Rıza; Efendioğlu, Kamran

    2014-09-01

    An important consideration in rhinoplasty is maintenance of the applied tip rotation. Different techniques have been proposed to accomplish this. Loss of rotation after surgery not only results in a derotated tip but also can create a supratip deformity. As a supplement to dorsal reconstruction, the authors introduced and applied the lateral crural rein flap technique, whereby cartilage flaps are created from the cephalic portion of the lateral crura to control and stabilize tip rotation. Eleven patients underwent primary open-approach rhinoplasty that included the lateral crural rein technique; the mean follow-up time was 18 months. Excess cephalic portions of the lateral crura were prepared as medial crura-based cartilaginous flaps and were incorporated into the nasal dorsum (similar to spreader grafts) and stabilized to achieve the desired tip rotation. The lateral crural rein flap technique provided stability to the nasal tip while minimizing derotation in the postoperative period. Long-term follow-up revealed maintenance of the nasal tip rotation and symmetric dorsal aesthetic lines. The lateral crural rein flap technique is effective for controlling nasal tip rotation while reducing lateral crural cephalic excess. Longevity of the applied tip rotation is reinforced by secure attachment of the lower nasal cartilage complex to the midvault structures. 4. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.

  5. Treatment of ischial pressure sores with double adipofascial turnover flaps.

    Science.gov (United States)

    Lin, Haodong; Hou, Chunlin; Xu, Zhen; Chen, Aiming

    2010-01-01

    Despite a variety of flap reconstruction options, the ischium remains the most difficult pressure sore site to treat. This article describes the authors' successful surgical procedure for coverage of ischial ulcers using double adipofascial turnover flaps.After debridement, the adipofascial flaps are harvested both cephalad and caudal to the defect. The flaps are then turned over to cover the exposed bone in a manner so as to overlap the 2 flaps. The skin is then closed with sutures in 2 layers. A total of 15 patients with ischial sores were treated using this surgical procedure.The follow-up period ranged from 11 to 159 months, with a mean of 93.6 months. Overall, 86.7% of the flaps (13 of 15) healed primarily. One patient had a recurrent grade II ischial pressure sore again 11 months after the operation. The other 14 patients did not have a recurrence.Treatment of ischial pressure sores with adipofascial turnover flaps provides an easy, minimally invasive procedure, with preservation of future flap options, and a soft-tissue supply sufficient for covering the bony prominence and filling dead space. This technique is a reliable and safe reconstructive modality for the management of minor ischial pressure sores.

  6. A lining vomer flap for palate pushback in unilateral cleft palate repair.

    Science.gov (United States)

    Clavin, H D; Owsley, J Q

    1978-01-01

    A combinaation vomer mucoperiosteal flap and nasal floor mucoperiosteal flap is described which is used to achieve nasal coverage in unilateral cleft palate patients requiring pushbacks. A posteriorly based readily accessible vomer flap is raised on the cleft side and used as nasal lining for the palatal mucoperiosteal flap on the non-cleft side. On the cleft side, a symmetrically sized nasal floor flap is easily elevated under direct vision and used to cover the nasal aspect of the corresponding mucoperiosteal palatal flap.

  7. Approach for Structurally Clearing an Adaptive Compliant Trailing Edge Flap for Flight

    Science.gov (United States)

    Miller, Eric J.; Lokos, William A.; Cruz, Josue; Crampton, Glen; Stephens, Craig A.; Kota, Sridhar; Ervin, Gregory; Flick, Pete

    2015-01-01

    The Adaptive Compliant Trailing Edge (ACTE) flap was flown on the National Aeronautics and Space Administration (NASA) Gulfstream GIII testbed at the NASA Armstrong Flight Research Center. This smoothly curving flap replaced the existing Fowler flaps creating a seamless control surface. This compliant structure, developed by FlexSys Inc. in partnership with the Air Force Research Laboratory, supported NASA objectives for airframe structural noise reduction, aerodynamic efficiency, and wing weight reduction through gust load alleviation. A thorough structures airworthiness approach was developed to move this project safely to flight. A combination of industry and NASA standard practice require various structural analyses, ground testing, and health monitoring techniques for showing an airworthy structure. This paper provides an overview of compliant structures design, the structural ground testing leading up to flight, and the flight envelope expansion and monitoring strategy. Flight data will be presented, and lessons learned along the way will be highlighted.

  8. Freestyle multiple propeller flap reconstruction (jigsaw puzzle approach) for complicated back defects.

    Science.gov (United States)

    Park, Sung Woo; Oh, Tae Suk; Eom, Jin Sup; Sun, Yoon Chi; Suh, Hyun Suk; Hong, Joon Pio

    2015-05-01

    The reconstruction of the posterior trunk remains to be a challenge as defects can be extensive, with deep dead space, and fixation devices exposed. Our goal was to achieve a tension-free closure for complex defects on the posterior trunk. From August 2006 to May 2013, 18 cases were reconstructed with multiple flaps combining perforator(s) and local skin flaps. The reconstructions were performed using freestyle approach. Starting with propeller flap(s) in single or multilobed design and sequentially in conjunction with adjacent random pattern flaps such as fitting puzzle. All defects achieved tensionless primary closure. The final appearance resembled a jigsaw puzzle-like appearance. The average size of defect was 139.6 cm(2) (range, 36-345 cm(2)). A total of 26 perforator flaps were used in addition to 19 random pattern flaps for 18 cases. In all cases, a single perforator was used for each propeller flap. The defect and the donor site all achieved tension-free closure. The reconstruction was 100% successful without flap loss. One case of late infection was noted at 12 months after surgery. Using multiple lobe designed propeller flaps in conjunction with random pattern flaps in a freestyle approach, resembling putting a jigsaw puzzle together, we can achieve a tension-free closure by distributing the tension to multiple flaps, supplying sufficient volume to obliterate dead space, and have reliable vascularity as the flaps do not need to be oversized. This can be a viable approach to reconstruct extensive defects on the posterior trunk. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. The rare sugar D-allose has a reducing effect against ischemia-reperfusion injury on the rat abdominal skin island flap model.

    Science.gov (United States)

    Muneuchi, Gan; Hossain, Akram; Yamaguchi, Fuminori; Ueno, Masaki; Tanaka, Yoshio; Suzuki, Shigehiko; Tokuda, Masaaki

    2013-08-01

    Recently, one of the rare sugars, D-allose, has received attention from many researchers because of its availability for mass production and its various physiological functions. Among these, an antioxidative effect has been strongly suggested. In this study, we investigated whether this effect is also applicable to the field of skin surgery. In ischemia-reperfusion injury model using the rat abdominal skin island flap (male Wistar rats, n = 110), D-allose was injected intravenously 15 min before 8-h ischemia. The survival area (%) was measured by digital photographic assessment 1 wk after surgery, and multiple comparisons (Fisher's protected least significant difference) were carried out. Histopathological examination (neutrophilic infiltration into dermis in hematoxylin and eosin stain) and immunostaining (of ectodermal dysplasia-1 (ED1)-positive cells/flap) were assessed. Myeloperoxidase (MPO) activity in the skin flap (sampling at the time of 8 h after reperfusion) was measured spectrophotometrically, and Student t-test was performed. D-allose extended the survival of the remaining flaps, and a dose greater than 30 mg (0.1 mg/g) was necessary to be effective. The flap survival rates in the 30, 60, and 150 mg groups were significantly higher than that in the control (saline) group: 75.87 ± 5.90, 79.27 ± 7.81, and 77.87 ± 6.20 versus 50.53 ± 9.66, respectively (P rare sugars are safer for our bodies as well as the environment; therefore, this rare sugar project is expected to lead to the development of a safer antioxidant for skin flap surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Experience with Perforator Based Flaps for Wound Cover of the Leg ...

    African Journals Online (AJOL)

    Background: Open fractures of the distal third of the tibia and fibular offer a challenge to the orthopedic surgeon because of skin coverage. The reconstructive surgeon's help is often required in trying to achieve this. There are several options: - local flap, free flap or a cross leg flap. Local flaps have always had limitations ...

  11. Reconstruction of trochanteric pressure sores with pedicled anterolateral thigh myocutaneous flaps.

    Science.gov (United States)

    Wang, Chih-Hsin; Chen, Shih-Yi; Fu, Ju-Peng; Dai, Niann-Tzyy; Chen, Shao-Liang; Chen, Tim-Mo; Chen, Shyi-Gen

    2011-05-01

    To provide an alternative choice for covering trochanteric pressure sores, we report on a modified pedicle anterolateral thigh (ALT) myocutaneous flap based on the descending branch of the lateral circumflex femoral artery. From August 2007 to January 2010, 20 consecutive patients (10 men and 10 women) underwent 21 pedicled ALT myocutaneous flaps for reconstruction of trochanteric pressure sores. The flap was designed and elevated, resembling the ALT perforator flap including part of the vastus lateralis muscle but without skeletonisation of the perforators. The mean age of patients was 79.4 years (range: 46-103). The mean follow-up period was 13.9 months (range: 3-32). The flaps were 8-21 cm long and 5-11 cm wide. All flaps healed without major complications. All donor sites were closed primarily without skin grafting and showed good aesthetic results. No recurrence was observed. This modified design of pedicled ALT myocutaneous flap without skeletonisation of perforators is a reliable and easily harvested flap for reconstruction of trochanteric pressure sores with limited morbidity. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  12. Unsteady Aerodynamics of Flapping Wing of a Bird

    Directory of Open Access Journals (Sweden)

    M. Agoes Moelyadi

    2013-04-01

    Full Text Available The unsteady flow behavior and time-dependent aerodynamic characteristics of the flapping motion of a bird’s wing were investigated using a computational method. During flapping, aerodynamic interactions between bird wing surfaces and surrounding flow may occur, generating local time-dependent flow changes in the flow field and aerodynamic load of birds. To study the effect of flapping speed on unsteady aerodynamic load, two kinds of computational simulations were carried out, namely a quasi-steady and an unsteady simulation. To mimic the movement of the down-stroke and the upstroke of a bird, the flapping path accorded to a sinus function, with the wing attitude changing in dihedral angle and time. The computations of time-dependent viscous flow were based on the solution of the Reynolds Averaged Navier-Stokes equations by applying the k-e turbulence model. In addition, the discretization for the computational domain around the model used multi-block structured grid to provide more accuracy in capturing viscous flow, especially in the vicinity of the wing and body surfaces, to obtain a proper wing-body geometry model. For this research, the seagull bird was chosen, which has high aspect ratio wings with pointed wing-tips and a high camber wing section. The results include mesh movement, velocity contours as well as aerodynamic coefficients of the flapping motion of the bird at various flapping frequencies.

  13. Application of microvascular free osteocutaneous flaps in the management of post-radiation recurrent oral cancer

    International Nuclear Information System (INIS)

    Rosen, I.B.; Manktelow, R.T.; Zuker, R.M.; Boyd, B.

    1985-01-01

    Fifty-nine patients underwent free flap osteocutaneous reconstruction that consisted of flaps of the dorsum of the foot in 26 patients and iliac crest flaps in 33 with a success rate of 92 percent and a mortality rate of 1.6 percent. These flaps, which require the expertise of microvascular surgeons, are time-consuming and complicate operating room and time management, but they represent a remarkable advance in reconstruction that can facilitate cosmetic and functional recovery of the patient. In particular, they promote healing in radiation-recurrent oral cancer and represent a definitive form of management for established radionecrosis of the mandible. The large volume of tissue available with iliac crest osteocutaneous grafts permits the management of patients with extensive cancer involving the skin, mucosa, and bone, but cancer control may still be disappointing and there is a need for improved adjuvant chemotherapy protocols. This technique appears to be a dependable, repeatable, and significant advance in management of the patient with head and neck cancer

  14. The forked flap repair for hypospadias

    Directory of Open Access Journals (Sweden)

    Anil Chadha

    2012-01-01

    Full Text Available Context: Despite the abundance of techniques for the repair of Hypospadias, its problems still persist and a satisfactory design to correct the penile curvature with the formation of neourethra from the native urethral tissue or genital or extragenital tissues, with minimal postoperative complications has yet to evolve. Aim: Persisting with such an endeavor, a new technique for the repair of distal and midpenile hypospadias is described. Materials and Methods: The study has been done in 70 cases over the past 11 years. The "Forked-Flap" repair is a single stage method for the repair of such Hypospadias with chordee. It takes advantage of the rich vascular communication at the corona and capitalizes on the established reliability of the meatal based flip-flap. The repair achieves straightening of the curvature of the penis by complete excision of chordee tissue from the ventral surface of the penis beneath the urethral plate. The urethra is reconstructed using the native plate with forked flap extensions and genital tissue relying on the concept of meatal based flaps. Water proofing by dartos tissue and reinforcement by Nesbit′s prepucial tissue transfer completes the one stage procedure. Statistical Analysis: An analysis of 70 cases of this single stage technique of repair of penile hypospadias with chordee, operated at 3 to 5 years of age over the past 11 years is presented. Results and Conclusion: The Forked Flap gives comparable and replicable results; except for a urethrocutaneous fistula rate of 4% no other complications were observed.

  15. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    Science.gov (United States)

    Thankappan, Krishnakumar; Trivedi, Nirav P.; Sharma, Mohit; Kuriakose, Moni A.; Iyer, Subramania

    2009-01-01

    A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome. PMID:19881028

  16. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    Directory of Open Access Journals (Sweden)

    Thankappan Krishnakumar

    2009-01-01

    Full Text Available A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome.

  17. 50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 1...

  18. A prospective, contralateral comparison of photorefractive keratectomy (PRK versus thin-flap LASIK: assessment of visual function

    Directory of Open Access Journals (Sweden)

    Hatch BB

    2011-04-01

    Full Text Available Bryndon B Hatch1, Majid Moshirfar1, Andrew J Ollerton1, Shameema Sikder2, Mark D Mifflin11John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 2Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USAPurpose: To compare differences in visual acuity, contrast sensitivity, complications, and higher-order ocular aberrations (HOAs in eyes with stable myopia undergoing either photorefractive keratectomy (PRK or thin-flap laser in situ keratomileusis (LASIK (intended flap thickness of 90 µm using the VISX Star S4 CustomVue excimer laser and the IntraLase FS60 femtosecond laser at 1, 3, and 6 months postoperatively.Methods: In this prospective, masked, and randomized pilot study, refractive surgery was performed contralaterally on 52 eyes: 26 with PRK and 26 with thin-flap LASIK. Primary outcome measures were uncorrected distance visual acuity (UDVA, corrected distance visual acuity (CDVA, contrast sensitivity, and complications.Results: At 6 months, mean values for UDVA (logMAR were -0.043 ± 0.668 and -0.061 ± 0.099 in the PRK and thin-flap LASIK groups, respectively (n = 25, P = 0.466. UDVA of 20/20 or better was achieved in 96% of eyes undergoing PRK and 92% of eyes undergoing thin-flap LASIK, whereas 20/15 vision or better was achieved in 73% of eyes undergoing PRK and 72% of eyes undergoing thin-flap LASIK (P > 0.600. Significant differences were not found between treatment groups in contrast sensitivity (P ≥ 0.156 or CDVA (P = 0.800 at postoperative 6 months. Types of complications differed between groups, notably 35% of eyes in the thin-flap LASIK group experiencing complications, including microstriae and 2 flap tears.Conclusion: Under well-controlled surgical conditions, PRK and thin-flap LASIK refractive surgeries achieve similar results in visual acuity, contrast sensitivity, and induction of HOAs, with differences in experienced complications.Keywords: photorefractive keratectomy, thin-flap LASIK, visual

  19. Medial circumflex femoral artery flap for ischial pressure sore

    Directory of Open Access Journals (Sweden)

    Palanivelu S

    2009-01-01

    Full Text Available A new axial pattern flap based on the terminal branches of the medial circumflex femoral artery is described for coverage of ischial pressure sore. Based on the terminal branches of the transverse branch of medial circumflex femoral artery, which exit through the gap between the quadratus femoris muscle above and the upper border of adductor magnus muscle below, this fascio cutaneous flap is much smaller than the posterior thigh flap but extremely useful to cover ischeal pressure sores. The skin redundancy below the gluteal fold allows a primary closure of the donor defect. It can also be used in combination with biceps femoris muscle flap.

  20. Aerodynamic optimization and mechanism design of flexible variable camber trailing-edge flap

    Directory of Open Access Journals (Sweden)

    Weishuang LU

    2017-06-01

    Full Text Available Trailing-edge flap is traditionally used to improve the takeoff and landing aerodynamic performance of aircraft. In order to improve flight efficiency during takeoff, cruise and landing states, the flexible variable camber trailing-edge flap is introduced, capable of changing its shape smoothly from 50% flap chord to the rear of the flap. Using a numerical simulation method for the case of the GA (W-2 airfoil, the multi-objective optimization of the overlap, gap, deflection angle, and bending angle of the flap under takeoff and landing configurations is studied. The optimization results show that under takeoff configuration, the variable camber trailing-edge flap can increase lift coefficient by about 8% and lift-to-drag ratio by about 7% compared with the traditional flap at a takeoff angle of 8°. Under landing configuration, the flap can improve the lift coefficient at a stall angle of attack about 1.3%. Under cruise state, the flap helps to improve the lift-to-drag ratio over a wide range of lift coefficients, and the maximum increment is about 30%. Finally, a corrugated structure–eccentric beam combination bending mechanism is introduced in this paper to bend the flap by rotating the eccentric beam.

  1. Biochemical and Cellular Assessment of Acetabular Chondral Flaps Identified During Hip Arthroscopy.

    Science.gov (United States)

    Hariri, Sanaz; Truntzer, Jeremy; Smith, Robert Lane; Safran, Marc R

    2015-06-01

    To analyze chondral flaps debrided during hip arthroscopy to determine their biochemical and cellular composition. Thirty-one full-thickness acetabular chondral flaps were collected during hip arthroscopy. Biochemical analysis was undertaken in 21 flaps from 20 patients, and cellular viability was determined in 10 flaps from 10 patients. Biochemical analysis included concentrations of (1) DNA (an indicator of chondrocyte content), (2) hydroxyproline (an indicator of collagen content), and (3) glycosaminoglycan (an indicator of chondrocyte biosynthesis). Higher values for these parameters indicated more healthy tissue. The flaps were examined to determine the percentage of viable chondrocytes. The percentage of acetabular chondral flap specimens that had concentrations within 1 SD of the mean values reported in previous normal cartilage studies was 38% for DNA, 0% for glycosaminoglycan, and 43% for hydroxyproline. The average cellular viability of our acetabular chondral flap specimens was 39% (SD, 14%). Only 2 of the 10 specimens had more than half the cells still viable. There was no correlation between (1) the gross examination of the joint or knowledge of the patient's demographic characteristics and symptoms and (2) biochemical properties and cell viability of the flap, with one exception: a degenerative appearance of the surrounding cartilage correlated with a higher hydroxyproline concentration. Although full-thickness acetabular chondral flaps can appear normal grossly, the biochemical properties and percentage of live chondrocytes in full-thickness chondral flaps encountered in hip arthroscopy show that this tissue is not normal. There has been recent interest in repairing chondral flaps encountered during hip arthroscopy. These data suggest that acetabular chondral flaps are not biochemically and cellularly normal. Although these flaps may still be valuable mechanically and/or as a scaffold in some conductive or inductive capacity, further study is

  2. Study of Flapping Flight Using Discrete Vortex Method Based Simulations

    Science.gov (United States)

    Devranjan, S.; Jalikop, Shreyas V.; Sreenivas, K. R.

    2013-12-01

    In recent times, research in the area of flapping flight has attracted renewed interest with an endeavor to use this mechanism in Micro Air vehicles (MAVs). For a sustained and high-endurance flight, having larger payload carrying capacity we need to identify a simple and efficient flapping-kinematics. In this paper, we have used flow visualizations and Discrete Vortex Method (DVM) based simulations for the study of flapping flight. Our results highlight that simple flapping kinematics with down-stroke period (tD) shorter than the upstroke period (tU) would produce a sustained lift. We have identified optimal asymmetry ratio (Ar = tD/tU), for which flapping-wings will produce maximum lift and find that introducing optimal wing flexibility will further enhances the lift.

  3. LASIK flap buttonhole treated immediately by PRK with mitomycin C.

    Science.gov (United States)

    Kymionis, George D; Portaliou, Dimitra M; Karavitaki, Alexandra E; Krasia, Maria S; Kontadakis, Georgios A; Stratos, Aimilianos; Yoo, Sonia H

    2010-03-01

    To describe the visual outcomes of three patients who had LASIK flap buttonhole and were treated immediately with photorefractive keratectomy (PRK) and topical mitomycin C (MMC) 0.02%. Three patients underwent bilateral LASIK with the SCHWIND Carriazo-Pendula 90 microm head microkeratome. In all three cases, a buttonhole flap occurred in the left eye. The flap was repositioned and phototherapeutic keratectomy for 50 microm was used for epithelial removal while immediate PRK with MMC was performed to treat the buttonhole flap. Three months after the procedure, uncorrected distance visual acuity and corrected distance visual acuity were 20/20 with regular topographic findings. Using PRK with MCC immediately after the occurrence of the LASIK flap buttonhole may be an effective treatment.

  4. Long-term Outcomes After Flap Reconstruction in Pediatric Pressure Ulcers.

    Science.gov (United States)

    Firriolo, Joseph M; Ganske, Ingrid M; Pike, Carolyn M; Caillouette, Catherine; Faulkner, Heather R; Upton, Joseph; Labow, Brian I

    2018-02-01

    Pressure ulcers refractory to nonoperative management may undergo flap reconstruction. This study aims to evaluate the long-term outcomes and recurrence rates of flap reconstruction for pediatric pressure ulcers. We reviewed the records of patients who underwent flap reconstruction for pressure ulcer(s) from 1995 to 2013. Twenty-four patients with 30 pressure ulcers, requiring 52 flaps were included. Ulcers were stages III and IV and mostly involved either the ischia (15/30) or sacrum (8/30). Flaps were followed for a median of 4.9 years. Twenty-three patients were wheelchair dependent, and 20 had sensory impairment at their ulcer site(s). Ten patients had a history of noncompliance with preoperative management, 8 of whom experienced ulcer recurrence. Twenty-one ulcers had underlying osteomyelitis, associated with increased admissions (P = 0.019) and cumulative length of stay (P = 0.031). Overall, there was a 42% recurrence rate in ulceration after flap reconstruction. Recurrence was associated with a preoperative history of noncompliance with nonoperative therapy (P = 0.030), but not with flap type or location, age, sex, body mass index, osteomyelitis, or urinary/fecal incontinence (P > 0.05, all). Flap reconstruction can be beneficial in the management of pediatric pressure ulcers. Although high rates of long-term success with this intervention have been reported in children, we found rates of ulcer recurrence similar to that seen in adults. Poor compliance with nonoperative care and failure to modify the biopsychosocial perpetuators of pressure ulcers will likely eventuate in postoperative recurrence. Despite the many comorbidities observed in our patient sample, compliance was the best indicator of long-term skin integrity and flap success.

  5. Ipsilateral fasciocutaneous flaps for leg and foot defects

    Directory of Open Access Journals (Sweden)

    Bhattacharya V

    2003-01-01

    Full Text Available It was a revolutionary enhancement for lower limb reconstruction when fasciocutaneous flaps were first described and used in clinical practice in 1981. Subsequently persistent studies were made to emphasize and confirm the rich vascular network associated with deep fascia. Thereafter studies were directed to identify the various types of perforators supplying the deep fascia and the overlying subcutaneous tissue and skin. Accordingly the scientists classified these flaps keeping in mind their clinical applications. The authors of this article have also performed extensive research on various aspects. This has led to better understanding about the finer details of vascularity. Based on this various modifications have been made for safe application of reconstruction for defects extending from knee to sole. To avoid complications the clinician should be able to select the proper procedure as regards the donor site and the possible preoperative and postoperative technical faults. A well-designed and meticulously executed flap usually has smooth recovery. Both Colour Doppler and Audio Doppler are useful tools in planning a safe flap. Now these flaps have proved to be standard technique without requiring a special set up extensive training.

  6. Botulinum toxin A and B raise blood flow and increase survival of critically ischemic skin flaps.

    Science.gov (United States)

    Schweizer, Dennis F; Schweizer, Riccardo; Zhang, Shengye; Kamat, Pranitha; Contaldo, Claudio; Rieben, Robert; Eberli, Daniel; Giovanoli, Pietro; Erni, Dominique; Plock, Jan A

    2013-10-01

    Botulinum toxin (BTX) A and B are commonly used for aesthetic indications and in neuromuscular disorders. New concepts seek to prove efficacy of BTX for critical tissue perfusion. Our aim was to evaluate BTX A and B in a mouse model of critical flap ischemia for preoperative and intraoperative application. BTX A and B were applied on the vascular pedicle of an axial pattern flap in mice preoperatively or intraoperatively. Blood flow, tissue oxygenation, tissue metabolism, flap necrosis rate, apoptosis assay, and RhoA and eNOS expression were endpoints. Blood-flow measurements 1 d after the flap operation revealed a significant reduction to 53% in the control group, while flow was maintained or increased in all BTX groups (103%-129%). Over 5 d all BTX groups showed significant increase in blood flow to 166-187% (P < 0.01). Microdialysis revealed an increase of glucose and reduced lactate/pyruvate ratio and glycerol levels in the flap tissue of all BTX groups. This resulted in significantly improved tissue survival in all BTX groups compared with the control group (62% ± 10%; all P < 0.01): BTX A preconditioning (84% ± 5%), BTX A application intraoperatively (88% ± 4%), BTX B preconditioning (91% ± 4%), and intraoperative BTX B treatment (92% ± 5%). This was confirmed by TUNEL assay. Immunofluorescence demonstrated RhoA and eNOS expression in BTX groups. All BTX applications were similarly effective, despite pharmacologic dissimilarities and different timing. In conclusion, we were able to show on a vascular, tissue, cell, and molecular level that BTX injection to the feeding arteries supports flap survival through ameliorated blood flow and oxygen delivery. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Surgeon-Based 3D Printing for Microvascular Bone Flaps.

    Science.gov (United States)

    Taylor, Erin M; Iorio, Matthew L

    2017-07-01

    Background  Three-dimensional (3D) printing has developed as a revolutionary technology with the capacity to design accurate physical models in preoperative planning. We present our experience in surgeon-based design of 3D models, using home 3D software and printing technology for use as an adjunct in vascularized bone transfer. Methods  Home 3D printing techniques were used in the design and execution of vascularized bone flap transfers to the upper extremity. Open source imaging software was used to convert preoperative computed tomography scans and create 3D models. These were printed in the surgeon's office as 3D models for the planned reconstruction. Vascularized bone flaps were designed intraoperatively based on the 3D printed models. Results  Three-dimensional models were created for intraoperative use in vascularized bone flaps, including (1) medial femoral trochlea (MFT) flap for scaphoid avascular necrosis and nonunion, (2) MFT flap for lunate avascular necrosis and nonunion, (3) medial femoral condyle (MFC) flap for wrist arthrodesis, and (4) free fibula osteocutaneous flap for distal radius septic nonunion. Templates based on the 3D models allowed for the precise and rapid contouring of well-vascularized bone flaps in situ, prior to ligating the donor pedicle. Conclusions  Surgeon-based 3D printing is a feasible, innovative technology that allows for the precise and rapid contouring of models that can be created in various configurations for pre- and intraoperative planning. The technology is easy to use, convenient, and highly economical as compared with traditional send-out manufacturing. Surgeon-based 3D printing is a useful adjunct in vascularized bone transfer. Level of Evidence  Level IV. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. Reconstruction of various perinasal defects using facial artery perforator-based nasolabial island flaps.

    Science.gov (United States)

    Yoon, Tae Ho; Yun, In Sik; Rha, Dong Kyun; Lee, Won Jai

    2013-11-01

    Classical flaps for perinasal defect reconstruction, such as forehead or nasolabial flaps, have some disadvantages involving limitations of the arc of rotation and two stages of surgery. However, a perforator-based flap is more versatile and allows freedom in flap design. We introduced our experience with reconstruction using a facial artery perforator-based propeller flap on the perinasal area. We describe the surgical differences between different defect subtypes. Between December 2005 and August 2013, 10 patients underwent perinasal reconstruction in which a facial artery perforator-based flap was used. We divided the perinasal defects into types A and B, according to location. The operative results, including flap size, arc of rotation, complications, and characteristics of the perforator were evaluated by retrospective chart review and photographic evaluation. Eight patients were male and 2 patients were female. Their mean age was 61 years (range, 35-75 years). The size of the flap ranged from 1 cm×1.5 cm to 3 cm×6 cm. Eight patients healed uneventfully, but 2 patients presented with mild flap congestion. However, these 2 patients healed by conservative management without any additional surgery. All of the flaps survived completely with aesthetically pleasing results. The facial artery perforator-based flap allowed for versatile customized flaps, and the donor site scar was concealed using the natural nasolabial fold.

  9. Deltoid muscular flap transfer for the treatment of irreparable rotator cuff tears

    Directory of Open Access Journals (Sweden)

    Justus Gille

    2009-09-01

    Full Text Available The purpose of this study was to evaluate the outcome of deltoid muscle flap transfer for the treatment of irreparable rotator cuff tears. In a retrospective study 20 consecutive patients were evaluated. The index procedure took place between 2000 and 2003. Fifteen patients were male, mean age was 62 years. Inclusion criterion was a rotator cuff defect Bateman grade IV. Exclusion criteria were smaller defects, shoulder instability and fractures of the injured shoulder. An open reconstruction with acromioplasty and a pedicled delta flap was performed. Follow up period was mean 42 months. Follow-up included clinical examination, Magnetic Resonance Imaging (MRI and the Constant and Simple (CS shoulder tests. According to the Constant shoulder test the results were good in 13 patients, fair in 5 and unsatisfactory in 2. The pre-operative Constant Score improved from mean 25.7 points (±5.3 to 72.3 (±7.8 at follow-up. The mean values for the subcategories of CS increased significantly from 3.9 to 14.4 points for pain and from 4.2 to 15.9 points for activities daily routine (p0.05. Results of the Simple Shoulder Test showed a significant increase of the mean values from pre-operative 4.3 to 14.7 points post-operatively. MRI showed a subacromial covering of the defect in all cases, all flaps where intact on MRI but always the flap showed marked fatty degeneration. In conclusion, the delta flap is a simple method for the repair of large defects of the rotator cuff leading to satisfying medium results.

  10. Unit Advancement Flap for Lower Lip Reconstruction.

    Science.gov (United States)

    Ogino, Akihiro; Onishi, Kiyoshi; Okada, Emi; Nakamichi, Miho

    2018-05-01

    Lower lip reconstruction requires consideration of esthetic and functional outcome in selecting a surgical procedure, and reconstruction with local tissue is useful. The authors reconstructed full-thickness defects with a unit advancement flap. Reconstruction was performed using this method in 4 patients with lower lip squamous cell carcinoma in whom tumor resection with preservation of the mouth angle was possible. The lower lip resection width was 30 to 45 mm, accounting for 50% to 68% of the entire width of the lower lip. The flap was prepared by lateral extension from above the mental unit and matched with the potential wrinkle line of the lower lip in order to design a unit morphology surrounded by the anterior margin of the depressor labii inferioris muscle. It was elevated as a full-thickness flap composed of the orbicularis oris muscle, skin, and mucosa of the residual lower lip from the bilateral sides, and advanced to the defect. Flap transfer was adjusted by small triangular resection of the skin on the lateral side of the mental unit. The postoperative scar was inconspicuous in all patients and there was no impairment of the mouth opening-closing or articulation functions. This was a relatively simple surgical procedure. A blood supply of the flap was stable, and continuity of the orbicularis oris muscle was reconstructed by transferred the residual lower lip advancement flap from the bilateral sides. The postoperative mouth opening-closing function was sufficient, and dentures could be placed from an early phase in elderly patients. The postoperative scar was consistent with the lip unit morphology, being esthetically superior. This procedure may be applicable for reconstruction of defects approximately 1/3 to 2/3 the width of the lower lip where the mouth angle is preserved.

  11. Atmospheric Full Scale Testing of a Morphing Trailing Edge Flap System for Wind Turbine Blades

    DEFF Research Database (Denmark)

    Barlas, Athanasios; Aagaard Madsen, Helge

    2015-01-01

    at the Risø Campus of DTU Wind Energy in Denmark. The design and instrumentation of the wing section and the AFS are described. The general description and objectives of the rotating test rig at the Risø campus of DTU are presented, along with an overview of sensors on the setup and the test cases. The post-processing...... of data is discussed and results of steady, flap step and azimuth control flap cases are presented....

  12. Rectus femoris muscle flap based on proximal insertion mobilization to cover a groin infected vascular graft.

    Science.gov (United States)

    Silvestre, Luís; Pedro, Luís Mendes; Fernandes e Fernandes, Ruy; Silva, Emanuel; Fernandes e Fernandes, José

    2015-10-01

    The rectus femoris (RF) muscle flap, which is widely used to cover groin infected vascular grafts, is usually harvested through distal tendon division and an extensive muscle elevation and transposition into the groin wound defect. A case of a vascular prosthetic graft infection in the groin was successfully controlled after coverage with an RF flap that was harvested based on proximal portion mobilization instead of the conventional distal one. This case suggests that the RF muscle flap based on proximal insertion mobilization is a feasible, effective, technically simpler, and less invasive alternative to cover infected vascular grafts in the groin. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. Extending the use of the gracilis muscle flap in perineal reconstruction surgery.

    Science.gov (United States)

    Goldie, Stephen J; Almasharqah, Riyadh; Fogg, Quentin A; Anderson, William

    2016-08-01

    Reconstruction of the perineum is required following oncological resections. Plastic surgical techniques can be used to restore the aesthetics and function of the perineum. The gracilis myocutaneous flap provides a substantial skin paddle, with minimal donor site morbidity. The flap is pedicled on a perforator from the medial circumflex femoral artery, giving it limited reach across the perineum. Tunnelling the flap under the adductor longus muscle may free up more of the arterial pedicle, increasing its reach. On three female cadavers, bilateral gracilis flaps were raised in the standard surgical manner, giving six flaps in total. With the flaps pedicled across the perineum, the distance from the tip of each flap was measured to the anterior superior iliac spine (ASIS). The flaps were then tunnelled under the adductor longus muscle. The distances to the ASIS were measured again. The average pedicle length was greater than 7 cm. Tunnelling the flap under the adductor longus muscle increased the reach by more than 4 cm on average. Cadaveric dissection has shown that tunnelling of the flap in a novel way increase its reach across the perineum. This additional flexibility improves its use clinically and is of benefit to plastic surgeons operating in perineal reconstruction. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Free tissue transfer versus pedicled flap reconstruction of head and neck malignancy defects.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-02-01

    BACKGROUND: With the advent of microsurgery the pedicled flap is considered by many to be an outdated surgical option. AIMS: To explore the relationship between flap survival and pre-morbid risk factors, conduct a comparative analysis of flap and systemic morbidities and complete a cosmesis and functionality assessment for oral and oropharyngeal reconstruction patients. METHODS: 114 patients, over a 13-year period, who had a one-stage reconstructive procedure employing the pectoralis major myocutaneous flap (PMMF) or radial forearm-free flap (RFFF). RESULTS: Variables, including age, smoking and radiation exposure were not statistically significant predictors of flap survival probability. Atelectasis was a significant post-op finding of RFFF patients. Flap dehiscence of >50% was a significant morbidity of PMMF. No statistical difference in cosmetic deformity, diet and socialisation was noted. CONCLUSIONS: Pectoralis major myocutaneous flap remains an enduring and safe flap; however, the RFFF has markedly improved speech performance over the PMMF.

  15. Development of Bird-like Micro Aerial Vehicle with Flapping and Feathering Wing Motions

    Science.gov (United States)

    Maglasang, Jonathan; Goto, Norihiro; Isogai, Koji

    To investigate the feasibility of a highly efficient flapping system capable of avian maneuvers, such as rapid takeoff, hover and gliding, a full scale bird-like (ornithopter) flapping-wing micro aerial vehicle (MAV) shaped and patterned after a typical pigeon (Columba livia) has been designed and constructed. Both numerical and experimental methods have been used in the development of this vehicle. This flapping-wing micro aerial vehicle utilizes both the flapping and feathering motions of an avian wing by employing a novel flapping-feathering mechanism, which has been synthesized and constructed so as to best describe the properly coordinated flapping and feathering wing motions at phase angle difference of 90° in a horizontal steady level flight condition. This design allows high flapping and feathering amplitudes and is configurable for asymmetric wing motions which are desirable in high-speed flapping flight and maneuvering. The preliminary results indicate its viability as a practical and an efficient flapping-wing micro aerial vehicle.

  16. The distally-based island ulnar artery perforator flap for wrist defects

    Directory of Open Access Journals (Sweden)

    Karki Durga

    2007-01-01

    Full Text Available Background: Reconstruction of soft tissue defects around the wrist with exposed tendons, joints, nerves and bone represents a challenge to plastic surgeons, and such defects necessitate flap coverage to preserve hand functions and to protect its vital structures. We evaluated the use of a distally-based island ulnar artery perforator flap in patients with volar soft tissue defects around the wrist. Materials and Methods: Between June 2004 and June 2006, seven patients of soft tissue defects on the volar aspect of the wrist underwent distally-based island ulnar artery perforator flap. Out of seven patients, five were male and two patients were female. This flap was used in the reconstruction of the post road traffic accident defects in four patients and post electric burn defects in three patients. Flap was raised on one or two perforators and was rotated to 180°. Results: All flaps survived completely. Donor sites were closed primarily without donor site morbidity. Conclusion: The distally-based island Ulnar artery perforator flap is convenient, reliable, easy to manage and is a single-stage technique for reconstructing soft tissue defects of the volar aspect of the wrist. Early use of this flap allows preservation of vital structures, decreases morbidity and allows for early rehabilitation.

  17. Rectus muscle flap tear as an independent cause of restricted motility.

    Science.gov (United States)

    Raab, Edward L; Ackert, Jessica M; Ostrovsky, Ann

    2012-08-01

    Most published cases of rectus muscle flap tear have been associated with orbital trauma of various degrees of severity. When they accompany an orbital fracture, however, it is difficult to determine whether the flap tear is merely an incidental additional finding or a major contributing cause of the resulting restriction. How to treat the flap itself remains an open question. We report a 24-year-old man with an inferior rectus muscle flap tear caused by direct laceration of the muscle. The major finding was a "reverse leash" vertical restriction. Discarding the flap instead of reattaching it did not prevent a successful result. Our case supports the proposition that rectus muscle flap tear can be a restriction-producing entity. Copyright © 2012 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  18. Free-flap surgical correction of facial deformity after anteromedial maxillectomy.

    Science.gov (United States)

    Sarukawa, Shunji; Kamochi, Hideaki; Noguchi, Tadahide; Sunaga, Ataru; Uda, Hirokazu; Mori, Yoshiyuki; Nishino, Hiroshi; Yoshimura, Kotaro

    2017-09-01

    Anteromedial maxillectomy is typically performed in conjunction with low-dose radiotherapy and intraarterial chemotherapy. In doing so, the extent of surgical defects is reduced. However, nasal deviation and oral incompetence may ensue, due to cicatricial contracture of wounds, and may be distressing to these patients. Herein, we report a series of eight free perforator flap procedures (anterolateral thigh [ALT] flap, 6; thoracodorsal artery perforator [TAP] flap, 2) used to correct such deformities. The TAP flap was combined with scapular tip [ST] osseous flap in patients with added zygomatic prominence defects. Three adipocutaneous parts developed from each perforator flap were applied as follows: two to reconstruct nasal lining and oral vestibule, and one to augment cheek volume. All aesthetic results proved satisfactory, although orbital dystopia and contracture of mimic muscles were not resolved completely. These secondary interventions are suitable for sequelae of simple anteromedial maxillectomy. Immediate reconstruction should be considered if orbital floor and mimic muscles are involved. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    Science.gov (United States)

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  20. Development of a piezoelectric actuator for trailing-edge flap control of rotor blades

    Science.gov (United States)

    Straub, Friedrich K.; Ngo, Hieu T.; Anand, V.; Domzalski, David B.

    1999-06-01

    Piezoelectric actuator technology has now reached a level where macro-positioning applications in the context of smart structures can be considered. One application with high payoffs is vibration reduction, noise reduction, and performance improvements in helicopters. Integration of piezoelectric actuators in the rotor blade is attractive, since it attacks the problem at the source. The present paper covers the development of a piezoelectric actuator for trailing edge flap control on a 34-foot diameter helicopter main rotor. The design of an actuator using bi-axial stack columns, and its bench, shake, and spin testing are described. A series of enhancements lead to an improved version that, together with use of latest stack technology, meets the requirements. Next steps in this DARPA sponsored program are development of the actuator and full scale rotor system for wind tunnel testing in the NASA Ames 40 X 80 foot wind tunnel and flight testing on the MD Explorer.

  1. Active aerodynamic stabilisation of long suspension bridges

    DEFF Research Database (Denmark)

    Nissen, Henrik Ditlev; Sørensen, Paul Haase; Jannerup, Ole Erik

    2004-01-01

    The paper describes the addition of actively controlled appendages (flaps) attached along the length of the bridge deck to dampen wind-induced oscillations in long suppension bridges. A novel approach using control systems methods for the analysis of dynamic stability is presented. In order to make...... use of control analysis and design techniques, a linear model of the structural and aerodynamic motion around equilibriun is developed. The model is validated through comparison with finite element calculations and wind tunnel experimental data on the Great Belt East Bridge in Denmark. The developed...... active control scheme is local in that the flap control signal at a given longitudinal position along the bridge only depends on local motion measurements. The analysis makes use of the Nyquist stability criteria and an anlysis of the sensitivity function for stability analysis. The analysis shows...

  2. Internal-external flow integration for a thin ejector-flapped wing section

    Science.gov (United States)

    Woolard, H. W.

    1979-01-01

    Thin airfoil theories of an ejector flapped wing section are reviewed. The global matching of the external airfoil flow with the ejector internal flow and the overall ejector flapped wing section aerodynamic performance are examined. Mathematical models of the external and internal flows are presented. The delineation of the suction flow coefficient characteristics are discussed. The idealized lift performance of an ejector flapped wing relative to a jet augmented flapped wing are compared.

  3. Reverse Saphenous Conduit Flap in 19 Dogs and 1 Cat.

    Science.gov (United States)

    Cavalcanti, Jacqueline V J; Barry, Sabrina L; Lanz, Otto I; Barnes, Katherine; Coutin, Julia V

    2018-05-14

    The purpose of this retrospective study was to report the outcomes of 19 dogs and 1 cat undergoing reverse saphenous conduit flap between 1999 and 2016. Reverse saphenous conduit flap was used to treat traumatic wounds and wounds resulting from tumor excision in the hind limb; the majority of cases had medial shearing injuries. All animals had complete flap survival. In five animals (20%), minor donor site dehiscence occurred, which did not require surgery. Other postoperative complications included signs of severe venous congestion in one dog. Reverse saphenous conduit flap is a useful technique to repair skin defects of the distal hind limb.

  4. A systematic review of complication and recurrence rates of musculocutaneous, fasciocutaneous, and perforator-based flaps for treatment of pressure sores.

    Science.gov (United States)

    Sameem, Mojib; Au, Michael; Wood, Thomas; Farrokhyar, Forough; Mahoney, James

    2012-07-01

    Management of pressure sores poses a significant reconstructive challenge for plastic surgeons. Currently, there is no consensus on whether musculocutaneous, fasciocutaneous, or perforator-based flaps provide superior results for treating pressure sores. The following databases were searched: Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, LILACS (January of 1950 to November of 2010), MEDLINE (January of 1950 to November of 2010), and EMBASE (January of 1980 to November of 2010). Only articles reporting on the use of musculocutaneous, fasciocutaneous, and perforator-based flaps were included. The primary study outcomes were complication and recurrence rates. Fifty-five articles were included in the final analysis (kappa = 0.78). From this total, 28 were categorized as pertaining to musculocutaneous flaps, 13 studied fasciocutaneous flaps, and 14 evaluated perforator-based flaps. The authors' review revealed recurrence and complication rates of 8.9 and 18.6 percent, respectively, following reconstruction with musculocutaneous flaps, 11.2 and 11.7 percent following reconstruction with fasciocutaneous flaps, and 5.6 and 19.6 percent following reconstruction with perforator-based flaps. Overall, statistical analysis revealed no significant difference in complication or recurrence rates among these three techniques. The authors' review revealed that there was no statistically significant difference with regard to recurrence or complication rates among musculocutaneous, fasciocutaneous, or perforator-based flaps. This suggests that surgeons performing such reconstructive procedures may choose to consider the advantages of a specific approach rather than the complication and recurrence rates. Therapeutic, IV.

  5. Comparative study of skin blood flow in various types of delayed deltopectoral flaps using the xenon-133 clearance method

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchida, Yukihide; Ogo, Ken (Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine); Tsuya, Akira; Uchida, Masaoki; Kamata, Shinetsu; Ohura, Takehiko

    1984-07-01

    We investigated the skin blood flow in five types of delayed deltopectoral flaps and the optimal time for transfer after delay operation using the local clearance method of Xenon-133. The results obtained are reported. 1) Characteristic differences were observed in recovery patterns of the distal blood flow among the five types of delay procedure. 2) The recovery in the distal blood flow of the D-P flap lined with a split-skin graft appeared the fastest among the five types, followed by the tubed D-P flap. 3) When using a bipedicled D-P flap, lateral incision should be performed within 10 days after delay procedure. 4) The skin blood flow of less than 5 ml/100g/min indicated a high risk of necrosis of the deltopectoral flap. 5) The optimal time for transfer was found to be when the skin blood flow of the distal region recovered to the control level.

  6. Efficiency of Lift Production in Flapping and Gliding Flight of Swifts

    Science.gov (United States)

    Henningsson, Per; Hedenström, Anders; Bomphrey, Richard J.

    2014-01-01

    Many flying animals use both flapping and gliding flight as part of their routine behaviour. These two kinematic patterns impose conflicting requirements on wing design for aerodynamic efficiency and, in the absence of extreme morphing, wings cannot be optimised for both flight modes. In gliding flight, the wing experiences uniform incident flow and the optimal shape is a high aspect ratio wing with an elliptical planform. In flapping flight, on the other hand, the wing tip travels faster than the root, creating a spanwise velocity gradient. To compensate, the optimal wing shape should taper towards the tip (reducing the local chord) and/or twist from root to tip (reducing local angle of attack). We hypothesised that, if a bird is limited in its ability to morph its wings and adapt its wing shape to suit both flight modes, then a preference towards flapping flight optimization will be expected since this is the most energetically demanding flight mode. We tested this by studying a well-known flap-gliding species, the common swift, by measuring the wakes generated by two birds, one in gliding and one in flapping flight in a wind tunnel. We calculated span efficiency, the efficiency of lift production, and found that the flapping swift had consistently higher span efficiency than the gliding swift. This supports our hypothesis and suggests that even though swifts have been shown previously to increase their lift-to-drag ratio substantially when gliding, the wing morphology is tuned to be more aerodynamically efficient in generating lift during flapping. Since body drag can be assumed to be similar for both flapping and gliding, it follows that the higher total drag in flapping flight compared with gliding flight is primarily a consequence of an increase in wing profile drag due to the flapping motion, exceeding the reduction in induced drag. PMID:24587260

  7. Efficiency of lift production in flapping and gliding flight of swifts.

    Directory of Open Access Journals (Sweden)

    Per Henningsson

    Full Text Available Many flying animals use both flapping and gliding flight as part of their routine behaviour. These two kinematic patterns impose conflicting requirements on wing design for aerodynamic efficiency and, in the absence of extreme morphing, wings cannot be optimised for both flight modes. In gliding flight, the wing experiences uniform incident flow and the optimal shape is a high aspect ratio wing with an elliptical planform. In flapping flight, on the other hand, the wing tip travels faster than the root, creating a spanwise velocity gradient. To compensate, the optimal wing shape should taper towards the tip (reducing the local chord and/or twist from root to tip (reducing local angle of attack. We hypothesised that, if a bird is limited in its ability to morph its wings and adapt its wing shape to suit both flight modes, then a preference towards flapping flight optimization will be expected since this is the most energetically demanding flight mode. We tested this by studying a well-known flap-gliding species, the common swift, by measuring the wakes generated by two birds, one in gliding and one in flapping flight in a wind tunnel. We calculated span efficiency, the efficiency of lift production, and found that the flapping swift had consistently higher span efficiency than the gliding swift. This supports our hypothesis and suggests that even though swifts have been shown previously to increase their lift-to-drag ratio substantially when gliding, the wing morphology is tuned to be more aerodynamically efficient in generating lift during flapping. Since body drag can be assumed to be similar for both flapping and gliding, it follows that the higher total drag in flapping flight compared with gliding flight is primarily a consequence of an increase in wing profile drag due to the flapping motion, exceeding the reduction in induced drag.

  8. Magnetic resonance imaging and clinical features of glenoid labral flap tears

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Jessica K.; Vinson, Emily N. [Duke University Hospital, Department of Radiology, Durham, NC (United States); Taylor, Dean C. [Duke University Hospital, Department of Orthopaedic Surgery, Durham, NC (United States)

    2017-08-15

    Displaced flaps of glenoid labral tissue are an uncommonly encountered finding on MRI of the shoulder, and are of unclear clinical significance. The purpose of this study is to describe the imaging characteristics of displaced glenoid labral flaps, evaluate for any common concomitant injuries, and identify the typical clinical presentation and management of patients with this lesion. This retrospective, observational study was approved by the institutional review board. Nineteen patients with flap-type tears of the labrum on preoperative MRI were identified. Each examination was retrospectively reviewed by two radiologists for size, location, and signal intensity of the displaced flap of tissue, in addition to any co-existing labrum or cartilage pathological conditions and clinical information. All displaced flaps extended from the inferior margin of the glenoid into the axillary recess. The average size of the visualized flap was 10.9 by 6.0 by 2.6 mm. Seventy percent of the flaps had signal intensity isointense to labrum and hypointense to hyaline cartilage on T2-weighted images. All 19 patients had concomitant labral pathological conditions and 63% had cartilage defects, visualized on MRI. Clinical evidence of shoulder instability was seen in 83% of patients, and 67% were managed surgically. Glenoid labral flap tears have distinct imaging characteristics that may aid in their identification. Their presence should prompt careful evaluation of the glenoid articular cartilage. Recognition of a labral flap tear may have clinical importance, as 83% of patients with this finding demonstrated clinical evidence of shoulder instability, often requiring surgical intervention. (orig.)

  9. Magnetic resonance imaging and clinical features of glenoid labral flap tears

    International Nuclear Information System (INIS)

    Stewart, Jessica K.; Vinson, Emily N.; Taylor, Dean C.

    2017-01-01

    Displaced flaps of glenoid labral tissue are an uncommonly encountered finding on MRI of the shoulder, and are of unclear clinical significance. The purpose of this study is to describe the imaging characteristics of displaced glenoid labral flaps, evaluate for any common concomitant injuries, and identify the typical clinical presentation and management of patients with this lesion. This retrospective, observational study was approved by the institutional review board. Nineteen patients with flap-type tears of the labrum on preoperative MRI were identified. Each examination was retrospectively reviewed by two radiologists for size, location, and signal intensity of the displaced flap of tissue, in addition to any co-existing labrum or cartilage pathological conditions and clinical information. All displaced flaps extended from the inferior margin of the glenoid into the axillary recess. The average size of the visualized flap was 10.9 by 6.0 by 2.6 mm. Seventy percent of the flaps had signal intensity isointense to labrum and hypointense to hyaline cartilage on T2-weighted images. All 19 patients had concomitant labral pathological conditions and 63% had cartilage defects, visualized on MRI. Clinical evidence of shoulder instability was seen in 83% of patients, and 67% were managed surgically. Glenoid labral flap tears have distinct imaging characteristics that may aid in their identification. Their presence should prompt careful evaluation of the glenoid articular cartilage. Recognition of a labral flap tear may have clinical importance, as 83% of patients with this finding demonstrated clinical evidence of shoulder instability, often requiring surgical intervention. (orig.)

  10. "Palmar pivot flap" for resurfacing palmar lateral defects of the fingers.

    Science.gov (United States)

    Yam, Andrew; Peng, Yeong-Pin; Pho, Robert Wan-Heng

    2008-12-01

    Soft tissue defects on the lateral borders of the digits are difficult to reconstruct using local or local-regional flaps. We describe a "palmar pivot flap" to resurface an adjacent defect on the palmar-lateral aspect of the digit. The surgical technique is described. This flap is an axial pattern flap based on the subcutaneous transverse branches of the digital artery. The flap is pivoted up to 90 degrees on the neurovascular bundle in its base, into an adjacent defect. The flap can be raised from either the proximal or the middle phalangeal segments. It can cover defects sited from the level of the proximal interphalangeal joint up to the fingertip. The donor defect is limited to the same digit and is covered with a full-thickness skin graft. We have used this flap on 3 patients with defects at the middle phalangeal segment, the distal interphalangeal joint, and the fingertip. All healed primarily. One patient had a mild flexion contracture of the proximal interphalangeal joint, whereas the other 2 had no complications. The patients with distal interphalangeal joint and fingertip defects had excellent sensation in the flap (2-point discrimination of 5-6 mm). The palmar pivot flap is useful for resurfacing otherwise difficult defects on the lateral borders of the digits around and distal to the proximal interphalangeal joint, including those at the fingertip. It provides sensate, glabrous skin. The donor defect is on the same digit and is well hidden, producing an aesthetic and functional reconstruction.

  11. Combination of Nasolabial V-Y Advancement Flap and Glabellar Subcutaneous Pedicled Flap for Reconstruction of Medial Canthal Defect

    Directory of Open Access Journals (Sweden)

    Hiromichi Matsuda

    2014-02-01

    Full Text Available A 77-year-old woman presented with a 1-year history of a right medial canthal tumor, which was histopathologically diagnosed as a basal cell carcinoma. After removal of the tumor with a 4-mm safety margin, the defect occupied the areas superior and inferior to the medial canthal tendon. We first reconstructed the lower part of the defect using a nasolabial V-Y advancement flap to make an elliptic defect in the upper part. We then created a glabellar subcutaneous pedicled flap to match the residual upper elliptic defect with the major axis set along a relaxed skin tension line. The pedicled glabellar flap was passed through a subcutaneous tunnel to the upper residual defect. At 6 months postoperatively, the patient showed no tumor recurrence and a good cosmetic outcome.

  12. Evaluation of diode laser and stannous fluoride in the treatment of root sensitivity after access flap surgery: Randomized controlled clinical trial.

    Science.gov (United States)

    Raut, Chetan Purushottam; Sethi, Kunal Sunder; Kohale, Bhagyashree; Mamajiwala, Alefiya; Warang, Ayushya

    2018-01-01

    Postsurgical root sensitivity has always been an enigma to the periodontists. There is a plethora of evidence suggesting the presence of root sensitivity following periodontal flap surgical procedures. Thus, the aim of the present study was to compare and evaluate the effect of low-power diode lasers with and without topical application of stannous fluoride (SnF 2 ) gel in the treatment of root sensitivity and also evaluate whether laser creates any placebo effect in the control group or not. Thirty patients participated in this study and 99 teeth were included. Root sensitivity was assessed for all groups with a Verbal Rating Scale (VRS). For each patient, the teeth were randomized into three groups. In the test Group I, sensitive teeth were treated with SnF 2 and diode laser. In the test Group II, sensitive teeth were irradiated with laser only. In the control group, no treatment was performed. The mean ± standard deviation (SD) score for VRS and Visual Analog Scale at baseline was not statistically significant ( P > 0.05) between the three groups. After 15 min, statistical significant difference was seen in test Group I and test Group II, although no difference was found in the control group. At 15 th day and 30 th day, the mean ± SD scores were statistically significant ( P diode lasers alone and in combination with 0.4% SnF 2 was effective in the treatment of root sensitivity after access flap surgery.

  13. Flapping wing flight can save aerodynamic power compared to steady flight.

    Science.gov (United States)

    Pesavento, Umberto; Wang, Z Jane

    2009-09-11

    Flapping flight is more maneuverable than steady flight. It is debated whether this advantage is necessarily accompanied by a trade-off in the flight efficiency. Here we ask if any flapping motion exists that is aerodynamically more efficient than the optimal steady motion. We solve the Navier-Stokes equation governing the fluid dynamics around a 2D flapping wing, and determine the minimal aerodynamic power needed to support a specified weight. While most flapping wing motions are more costly than the optimal steady wing motion, we find that optimized flapping wing motions can save up to 27% of the aerodynamic power required by the optimal steady flight. We explain the cause of this energetic advantage.

  14. Reconstruction of Nasal Skin Cancer Defects with Local Flaps

    Directory of Open Access Journals (Sweden)

    A. C. Salgarelli

    2011-01-01

    Full Text Available Reconstruction of nasal defects must preserve the integrity of complex facial functions and expressions, as well as facial symmetry and a pleasing aesthetic outcome. The reconstructive modality of choice will depend largely on the location, size, and depth of the surgical defect. Individualized therapy is the best course, and numerous flaps have been designed to provide coverage of a variety of nasal-specific defects. We describe our experience in the aesthetic reconstruction of nasal skin defects following oncological surgery. The use of different local flaps for nasal skin cancer defects is reported in 286 patients. Complications in this series were one partial flap dehiscence that healed by secondary intention, two forehead flaps, and one bilobed flap with minimal rim necrosis that resulted in an irregular scar requiring revision. Aesthetic results were deemed satisfactory by all patients and the operating surgeons. The color and texture matches were aesthetically good, and the nasal contour was distinct in all patients. All scars were inconspicuous and symmetrical. No patient had tenting or a flat nose.

  15. Reconstruction of Nasal Skin Cancer Defects with Local Flaps

    International Nuclear Information System (INIS)

    Salgarelli, A. C.; Bellini, P.; Multinu, A.; Consolo, U.; Magnoni, C.; Francomano, M.; Fantini, F.; Seidenari, S.

    2011-01-01

    Reconstruction of nasal defects must preserve the integrity of complex facial functions and expressions, as well as facial symmetry and a pleasing aesthetic outcome. The reconstructive modality of choice will depend largely on the location, size, and depth of the surgical defect. Individualized therapy is the best course, and numerous flaps have been designed to provide coverage of a variety of nasal-specific defects. We describe our experience in the aesthetic reconstruction of nasal skin defects following oncological surgery. The use of different local flaps for nasal skin cancer defects is reported in 286 patients. Complications in this series were one partial flap dehiscence that healed by secondary intention, two forehead flaps, and one bilobed flap with minimal rim necrosis that resulted in an irregular scar requiring revision. Aesthetic results were deemed satisfactory by all patients and the operating surgeons. The color and texture matches were aesthetically good, and the nasal contour was distinct in all patients. All scars were inconspicuous and symmetrical. No patient had tenting or a flat nose.

  16. Investigation of piezoelectric flaps for load alleviation using CFD; Wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Heinz, J.C.

    2010-03-15

    Cost efficient wind power generation demands for large wind turbines with a long lifetime. These demands place high interests on sophisticated load control techniques such as deformable trailing edge flaps. In this work a previously tested prototype airfoil was investigated by using the 2D incompressible RANS solver EllipSys2D. The prototype was built with a Risoe-B1-18 airfoil where piezoelectric actuators THUNDER TH-6R were attached at the trailing edge to realize a movable flap. The results of the simulation were compared to measurements of the previous wind tunnel test and comprehensive steady state computations were conducted to gain information about the general airfoil properties. The model was subsequently used to investigate aero-servo-elastic effects on the 2D airfoil section exposed to a fluctuating inflow. It is explained how a fluctuating inflow was simulated with EllipSys2D and how the CFD solver was coupled with a 3 DOF structural model and with two different control algorithms. Control 1 used the measured AOA in front of the LE as input, Control 2 used the pressure difference between suction and pressure side as input. The model showed a substantial load reduction potential for the present prototype airfoil. For a wind step from 10 m/s to 10.5 m/s the standard deviation of the structural deflection normal to the rotor plane could be reduced with up to 98 % (Control 1) and 96 % (Control 2). A 4 s turbulent inflow with TI=2.2 % could be reduced with up to 81 % (Control 1) and 82 % (Control 2). For a 12 s inflow with TI=2.4 % the standard deviation could be reduced with up to 68 % (Control 1) and 67 % (Control 2). The influence of possible time lags inside the control loop on the reduction potential of the prototype was also investigated. For a 12 s inflow with a tripled turbulence intensity of TI=7.7 % the prototype airfoil could still reach a reduction of up to 54 %. For an extended flap range of -6 to +6 degrees the reduction could be returned to 66

  17. Palatoplasty: suturing the mucoperiosteal flaps to the hard palate through hole.

    Science.gov (United States)

    Hwang, Kun; Lee, Ji Hun; Kim, Yu Jin; Le, Se Il

    2009-05-01

    We satisfactorily repaired a wide cleft palate using a method of V-Y pushback and anchoring the oral mucoperiosteal flap onto the bony ridge of the cleft. An 8-year-old Vietnamese girl had a wide incomplete bilateral posterior cleft palate associated with congenital cardiac malformations. The gap of the posterior cleft was 2.5 cm, which exceeded the total widths of the palatal shelves. We applied V-Y pushback and used a vomer flap to close the wide cleft palate. The posterior two thirds of the nasal mucosae from the cleft margins were sutured to the vomer flap. The nasal side of the anterior one third of the bony cleft was uncovered. The elevated bilateral mucoperiosteal flaps were brought together to the midline and sutured to the anterior triangular flap in a V-Y pushback fashion. Four holes were drilled 5 mm lateral to each bony cleft margin. The lateral sides of the mucoperiosteal flaps were fixed to the palate bone with 3-0 Vicryl through the hole. This method reduces the tension of the flap which might frequently cause oronasal fistula and also improve viability.

  18. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  19. Experimental and numerical study of an autonomous flap

    NARCIS (Netherlands)

    Bernhammer, L.O.; Navalkar, S.T.; Sodja, J.; De Breuker, R.; Karpel, M.

    2015-01-01

    This paper presents the experimental and numerical study of an autonomous load alleviation concept using trailing edge flaps. The flaps are autonomous units, which for instance can be used for gust load alleviation. The unit is self-powered and self-actuated through trailing edge tabs which are

  20. A simple concept for covering pressure sores: wound edge-based propeller perforator flap.

    Science.gov (United States)

    Kelahmetoglu, Osman; Van Landuyt, Koenraad; Yagmur, Caglayan; Sommeling, Casper E; Keles, Musa K; Tayfur, Volkan; Simsek, Tekin; Demirtas, Yener; Guneren, Ethem

    2017-12-01

    We present a new surgical modification to allow propeller perforator flaps to cover pressure sores at various locations. We used a propeller perforator flap concept based on the detection of newly formed perforator vessels located 1 cm from the wound margin and stimulated by the chronic inflammation process. Between January 2009 and January 2017, 33 wound edge-based propeller perforator flaps were used to cover pressure sores at various locations in 28 patients. In four cases more than one flap was used on the same patient. The patients comprised 18 males and 10 females with a mean age of 41·25 (range, 16-70) years. All patients underwent follow-up for 0-12 months. The mean follow-up duration was 5·03 months. Venous congestion was observed in three flaps that were rotated by 180° (9·1%). However, there was a significant difference between flaps rotated by 90° and 180° according to the complication rate (P = 0·034). Out of 33 flaps, 29 flaps healed uneventfully. Patients were able to sit and lie on their flaps three weeks after surgery. In our study, we were able to obtain satisfying final results using these novel flaps. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. Variability of extreme flap loads during turbine operation

    Energy Technology Data Exchange (ETDEWEB)

    Ronold, K O [Det Norske Veritas, Hoevik (Norway); Larsen, G C [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1999-03-01

    The variability of extreme flap loads is of utmost importance for design of wind-turbine rotor blades. The flap loads of interest consist of the flap-wise bendin moment response at the blade root whose variability in the short-term, for a given wind climate, can be represented by a stationary process. A model for the short-term bending moment process is presented, and the distribution of its associated maxima is derived. A model for the wind climate is given in terms of the probability distributions for the 10-minute mean wind speed and the standard deviation of the arbitrary wind speed. This is used to establish the distribution of the largest flap-wise bending moment in a specific reference period, and it is outlined how a characteristic bending moment for use in design can be extracted from this distribution. The application of the presented distribution models is demonstrated by a numerical example for a site-specific wind turbine. (au)

  2. Modeling the effects of control systems of wind turbine fatigue life

    Energy Technology Data Exchange (ETDEWEB)

    Pierce, K.G.; Laino, D.J. [Univ. of Utah, Salt Lake City, UT (United States)

    1996-12-31

    In this study we look at the effect on fatigue life of two types of control systems. First, we investigate the Micon 65, an upwind, three bladed turbine with a simple yaw control system. Results indicate that increased fatigue damage to the blade root can be attributed to continuous operation at significant yaw error allowed by the control system. Next, we model a two-bladed teetered rotor turbine using three different control systems to adjust flap deflections. The first two limit peak power output, the third limits peak power and cyclic power output over the entire range of operation. Results for simulations conducted both with and without active control are compared to determine how active control affects fatigue life. Improvement in fatigue lifetimes were seen for all control schemes, with increasing fatigue lifetime corresponding to increased flap deflection activity. 13 refs., 6 figs., 2 tabs.

  3. Three-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2 and two different femtosecond lasers (FS60 and FS200

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2013-04-01

    Full Text Available A John Kanellopoulos,1,2 George Asimellis1 1Laservision.gr Institute, Athens, Greece; 2NYU Medical School, New York, USA Purpose: To evaluate programmed versus achieved laser-assisted in situ keratomileusis (LASIK flap central thickness and investigate topographic flap thickness variability, as well as the effect of potential epithelial remodeling interference on flap thickness variability. Patients and methods: Flap thickness was investigated in 110 eyes that had had bilateral myopic LASIK several years ago (average 4.5 ± 2.7 years; range 2–7 years. Three age-matched study groups were formed, based on the method of primary flap creation: Group A (flaps made by the Moria Surgical M2 microkeratome [Antony, France], Group B (flaps made by the Abbott Medical Optics IntraLase™ FS60 femtosecond laser [Santa Ana, CA, USA], and Group C (flaps made by the Alcon WaveLight® FS200 femtosecond laser [Fort Worth, TX, USA]. Whole-cornea topographic maps of flap and epithelial thickness were obtained by scanning high-frequency ultrasound biomicroscopy. On each eye, topographic flap and epithelial thickness variability was computed by the standard deviation of thickness corresponding to 21 equally spaced points over the entire corneal area imaged. Results: The average central flap thickness for each group was 138.33 ± 12.38 µm (mean ± standard deviation in Group A, 128.46 ± 5.72 µm in Group B, and 122.00 ± 5.64 µm in Group C. Topographic flap thickness variability was 9.73 ± 4.93 µm for Group A, 8.48 ± 4.23 µm for Group B, and 4.84 ± 1.88 µm for Group C. The smaller topographic flap thickness variability of Group C (FS200 was statistically significant compared with that of Group A (M2 (P = 0.004, indicating improved topographic flap thickness consistency – that is, improved precision – over the entire flap area affected. Conclusions: The two femtosecond lasers produced a smaller flap thickness and reduced variability than the mechanical

  4. Nasoseptal flap for palatal reconstruction after hemi-maxillectomy: case report.

    Science.gov (United States)

    Alwashahi, M K; Battaglia, P; Turri-Zanoni, M; Castelnuovo, P

    2018-01-01

    Palatal reconstruction following maxillectomy is a surgical challenge, and a nasoseptal flap is a feasible approach. This paper reports the first known successful clinical case of a nasoseptal pedicle flap applied for the reconstruction of maxillary bone following hemi-maxillectomy. This report describes hemi-maxillectomy in a 60-year-old Italian male diagnosed with stage IV squamous cell carcinoma of the left maxilla. Endoscopic transnasal extended medial maxillectomy was performed, followed by a transoral modified midfacial degloving technique for removal of the maxillary bone. The contralateral nasoseptal pedicle flap was used to reconstruct the defect. The case was followed up prospectively for the assessment of flap reception and healing. The locally accessible nasoseptal flap is a viable alternative for palatal reconstruction; therefore, a second surgical procedure with its associated donor site morbidity can be avoided. Large-scale studies may help in establishing the cosmetic and functional outcomes.

  5. The Anconeus Muscle Free Flap: Clinical Application to Lesions on the Hand

    Directory of Open Access Journals (Sweden)

    Byung-Joon Jeon

    2017-09-01

    Full Text Available Background It can be difficult to select an appropriate flap for various defects on the hand. Although defects of the hand usually must be covered with a skin flap, some defects require a flap with rich blood supply and adequate additive soft tissue volume. The authors present their experience with the anconeus muscle free flap in the reconstruction of various defects and the release of scar contractures of the hand. Methods Ten patients underwent reconstruction of the finger or release of the first web space using the anconeus muscle free flap from May 1998 to October 2013. Adequate bed preparations with thorough debridement or contracture release were performed. The entire anconeus muscle, located at the elbow superficially, was harvested, with the posterior recurrent interosseous artery as a pedicle. The defects were covered with a uniformly trimmed anconeus muscle free flap. Additional debulking of the flap and skin coverage using a split-thickness skin graft were performed 3 weeks after the first operation. Results The average flap size was 18.7 cm2 (range, 13.5–30 cm2. All flaps survived without significant complications. Vein grafts for overcoming a short pedicle were necessary in 4 cases. Conclusions The anconeus muscle free flap can be considered a reliable reconstructive option for small defects on the hand or contracture release of the web space, because it has relatively consistent anatomy, provides robust blood supply within the same operative field, and leads to no functional loss at the donor site.

  6. Flight test operations using an F-106B research airplane modified with a wing leading-edge vortex flap

    Science.gov (United States)

    Dicarlo, Daniel J.; Brown, Philip W.; Hallissy, James B.

    1992-01-01

    Flight tests of an F-106B aircraft equipped with a leading-edge vortex flap, which represented the culmination of a research effort to examine the effectiveness of the flap, were conducted at the NASA Langley Research Center. The purpose of the flight tests was to establish a data base on the use of a wing leading-edge vortex flap as a means to validate the design and analysis methods associated with the development of such a vortical flow-control concept. The overall experiment included: refinements of the design codes for vortex flaps; numerous wind tunnel entries to aid in verifying design codes and determining basic aerodynamic characteristics; design and fabrication of the flaps, structural modifications to the wing tip and leading edges of the test aircraft; development and installation of an aircraft research instrumentation system, including wing and flap surface pressure measurements and selected structural loads measurements; ground-based simulation to assess flying qualities; and finally, flight testing. This paper reviews the operational aspects associated with the flight experiment, which includes a description of modifications to the research airplane, the overall flight test procedures, and problems encountered. Selected research results are also presented to illustrate the accomplishments of the research effort.

  7. A comparison of surgical outcome of fasciocutaneous V–Y advancement flap and Limberg transposition flap for recurrent sacrococcygeal pilonidal sinus disease

    Directory of Open Access Journals (Sweden)

    Bahadır Öz

    2017-05-01

    Conclusion: Limberg transposition flap may be use in recurrent cases of PSD, because of the lower recurrence rate and less hospital stay time, early return to work. Most important advantage of fasciocutaneous V–Y advancement flap is the ability to close larger defects in recurrent cases.

  8. Primary Observations on the Influence of 60Co Local Irradiation on Free Skin Flaps

    Institute of Scientific and Technical Information of China (English)

    杨建荣; 张园

    2002-01-01

    Objective To study the effect of postoperative radiation on free skin flaps.Methods Twenty-nine patients with free skin flaps applied to the plerosis of the postoperative defectwere followed up. Twenty-eight out of 29 patients received forearm free flaps while 1 had anterolater-al femoris skin flaps in a size ranging from 14 cm× 6 cm to 8 cm× 4 cm. These flaps were exposedto 60Co radiation ranging 40-69 Gy. Results Observation during irradiation: no visible changes ofskin flaps and oral mucous membrane were detected when irradiation dose was within 40 Gy; somechanges may be detected over 40 Gy. Observation 1 - 4 months after irradiation: pigmentations werefound in areas of erosion epidermis; skin flaps got dark but without evidence of necrosis. Observation2 years after irradiation: no necrosis happened in 29 skin flaps. Hairs were found on 15 of 29flaps. Sensation occurred within the margin of 1 cm. Conclusion Free skin flap can endure irradi-ation at the dose of 60 Gy.

  9. Seromuscular Colonic Flap for Intrapelvic Soft-Tissue Coverage: A Reconstructive Option for Plastic Surgeons When Traditionally Used Flaps Are Not Available

    Directory of Open Access Journals (Sweden)

    Johnathon Aho

    2015-01-01

    Full Text Available Background. Reconstruction of intrapelvic defects can be a challenging problem in patients with limited regional muscle flap options and previously resected omentum. In such situations, alternative methods of mobilizing vascularized tissue may be required. Methods. A case of a patient that underwent pelvic extirpation for recurrent rectal cancer who had limited donor sites for flap reconstruction is presented. The mucosa was removed from a blind loop of colon, and a pedicled seromuscular flap based on the colonic mesentery was placed into the pelvis for vascularized soft-tissue coverage and elimination of dead space. Results. The postoperative course was only complicated by a small subcutaneous fluid collection beneath the sacrectomy skin incision, which was drained with radiological assistance. The patient recovered without any major postoperative complications. Conclusion. Seromuscular colonic flap is a useful option for soft-tissue coverage after pelvic extirpation and should be considered by plastic surgeons when other reconstruction options are not available.

  10. Microvascular free flaps in the management of war wounds with tissue defects

    Directory of Open Access Journals (Sweden)

    Kozarski Jefta

    2003-01-01

    Full Text Available Background. War wounds caused by modern infantry weapons or explosive devices are very often associated with the defects of soft and bone tissue. According to their structure, tissue defects can be simple or complex. In accordance with war surgical doctrine, at the Clinic for Plastic Surgery and Burns of the Military Medical Academy, free flaps were used in the treatment of 108 patients with large tissue defects. With the aim of closing war wounds, covering deep structures, or making the preconditions for reconstruction of deep structures, free flaps were applied in primary, delayed, or secondary term. The main criteria for using free flaps were general condition of the wounded, extent, location, and structure of tissue defects. The aim was also to point out the advantages and disadvantages of the application of free flaps in the treatment of war wounds. Methods. One hundred and eleven microvascular free flaps were applied, both simple and complex, for closing the war wounds with extensive tissue defects. The main criteria for the application of free flaps were: general condition of the wounded, size, localization, and structure of tissue defects. For the extensive defects of the tissue, as well as for severely contaminated wounds latissimus dorsi free flaps were used. For tissue defects of distal parts of the lower extremities, scapular free flaps were preferred. While using free tissue transfer for recompensation of bone defects, free vascularized fibular grafts were applied, and in skin and bone defects complex free osteoseptocutaneous fibular, free osteoseptocutaneous radial forearm, and free skin-bone scapular flaps were used. Results. After free flap transfer 16 (14,4% revisions were performed, and after 8 unsuccessful revisions another free flaps were utilized in 3 (37,5% patients, and cross leg flaps in 5 (62,5% patients. Conclusion. The treatment of war wounds with large tissue defects by the application of free microvascular flaps

  11. Reconstruction in extensive axillary Hidradenitis suppurativa with local fasciocutaneous V-Y advancement flaps

    Directory of Open Access Journals (Sweden)

    Sharma Ramesh

    2006-01-01

    Full Text Available We present our experience with the use of local fasciocutaneous V-Y advancement flaps in the reconstruction of 10 axillae in 6 patients for large defects following wide excision of long-standing Hidradenitis suppurativa of the axilla. The defects were closed with local V-Y subcutaneous island flaps. A single flap from the chest wall was sufficient for moderate defects. However, for larger defects, an additional flap was taken from the medial side of the ipsilateral arm. The donor defects could be closed primarily in all the patients. The local areas of the lateral chest wall and the medial side of the arm have a plentiful supply of cutaneous perforators and the flaps can be designed in a V-Y fashion without resorting to preoperative marking of the perforator. The flaps were freed sufficiently to allow adequate movement for closure of the defects. Although no attempt was made to identify the perforators specifically, many perforators were seen entering the flap. Some perforators can be safely divided to increase reach of the flap. All the flaps survived completely. A follow up of 2.5 years is presented.

  12. A study on the aerodynamic characteristics of airfoil in the flapping adjustment stage during forward flight

    Science.gov (United States)

    Luo, Pan; Zhang, Xingwei; Huang, Panpan; Xie, Lingwang

    2017-10-01

    The aim of this study is to investigate the aerodynamic characteristics of a flapping airfoil in the adjustment stage between two specific flight patterns during the forward flight. Four flapping movement models in adjustment stage are firstly established by using the multi-objective optimization algorithm. Then, a numerical experiment is carried out by using finite volume method to solve the two-dimensional time-dependent incompressible Navier-Stokes equations. The attack angles are selected from -5° to 7.5° with an increase of 2.5°. The results are systematically analyzed and special attention is paid to the corresponding changes of aerodynamic forces, vortex shedding mechanism in the wake structure and thrust efficiency. Present results show that output aerodynamic performance of flapping airfoil can be improved by the increasement of amplitude and frequency in the flapping adjustment stage, which further validates and complements previous studies. Moreover, it is also show that the manner using multi-objective optimization algorithm to generate a movement model in adjustment stage, to connect other two specific plunging motions, is a feasible and effective method. Current study is dedicated to providing some helpful references for the design and control of artificial flapping wing air vehicles.

  13. Propeller Flap for Complex Distal Leg Reconstruction: A Versatile ...

    African Journals Online (AJOL)

    equipment, cost, steep learning curve, and prolonged operating ... A Versatile Alternative when Reverse Sural Artery Flap is .... He had wound debridement, fracture reduction, and .... flaps that were raised in the patient and the logistics of limb.

  14. 2D numerical comparison of trailing edge flaps - UpWind WP1B3

    Energy Technology Data Exchange (ETDEWEB)

    Buhl, T.; Andersen, Peter B. (Risoe National Lab., DTU (DK)); Barlas, T.K. (DUWIND, Delft Technical Univ. (NL))

    2007-11-15

    This report covers the investigations and comparisons of trailing edge flaps carried out by Delft and Risoe. The work is a part of the W1B3 work package of the UpWind EU-project. This report covers only 2D test cases with simple control of the trailing edge flap with the objective of keeping CL constant. The 5MW UpWind reference turbine is used for the calculations. The section in 75% radius is investigated for three different cases; (1) a wind step from 10m/s to 11m/s, (2) a wind 'gust' from 10 m/s to 14m/s in 1 second and followed by 10m/s, (3) finally a turbulent wind series is simulated, and the performance of the flaps is investigated. The two different codes from Delft and Risoe are compared in the mentioned cases. (au)

  15. Fingertip reconstruction with simultaneous flaps and nail bed grafts following amputation.

    Science.gov (United States)

    Hwang, Euna; Park, Byung Ho; Song, Seung Yong; Jung, Ho Sung; Kim, Chung Hun

    2013-07-01

    To report our technique and results with treating fingertip amputations with flaps and simultaneous nailbed grafts. We reconstructed 20 fingertip amputations with loss of bone and nail with flaps combined with nailbed grafts. We reconstructed the volar side of the fingertip with a flap, and the dorsal side of the fingertip with a nailbed grafted to the raw inner surface of the flap. We employed volar V-Y advancement flaps for transverse or dorsal oblique fingertip injuries and generally used abdominal flaps for volar oblique fingertip injuries. We harvested nailbeds from the amputated finger or from the patient's first toe. The length of the amputated fingertips was restored with the flaps, and the lost nailbeds were restored to their natural appearance with the nailbed grafts. We classified the results according to the length of the reconstructed fingertip and the appearance of the nail. Excellent or good results were achieved in 16 cases. Three cases had fair results and 1 had a poor result. We observed favorable results for distal fingertip amputations (Allen type II or III). In particular, most cases that were reconstructed with volar V-Y advancement flaps combined with nailbed grafts demonstrated favorable results. This method is useful for the restoration of dorsal oblique or transverse type fingertip amputations and is a good alternative when replantation is not an option. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. Versatility of the Angularis Oris Axial Pattern Flap for Facial Reconstruction.

    Science.gov (United States)

    Losinski, Sara L; Stanley, Bryden J; Schallberger, Sandra P; Nelson, Laura L; Towle Millard, Heather A M

    2015-11-01

    To describe the versatility of the axial pattern flap based on the cutaneous perforating branch of the angularis oris artery for reconstruction of large facial defects in dogs, including complications and clinical outcomes. Retrospective clinical case series. Client-owned dogs (n = 8). Facial flaps (n = 9) based at the commissure of the lip with a caudodorsal orientation were utilized, with established anatomical borders. Flaps were elevated deep to the panniculus carnosus in a caudal to rostral direction, preserving the angularis oris artery, its cutaneous perforator, and surrounding cutaneous vasculature. Flaps were rotated dorsally or ventrally to cover the defect. Primary closure of the donor site was by direct apposition in all cases. Angularis oris axial pattern flaps were most commonly used to close large defects of the nasomaxillary area rostral to the eyes (6 dogs), followed by orbital (2) and intermandibular (1) defects. Defects occurred because of tumor resection (6 dogs), trauma (2), and a chronic, non-healing wounding (1). All flaps healed with acceptable functional and cosmetic outcomes without major complications. Followup ranged from 10 days to 16 months. Minor postoperative complications included flap edema (8 dogs), partial incisional dehiscence (3), distal tip necrosis (2), and oroantral fistula recurrence (1). Angularis oris axial pattern flaps provided hirsute, full-thickness skin coverage of a variety of large facial defects with minor complications, and should be considered when restructuring large defects of the rostral face or chin. © Copyright 2015 by The American College of Veterinary Surgeons.

  17. Osteoradionecrosis of the olecranon: treatment by radial forearm flap

    International Nuclear Information System (INIS)

    Thornton, J.W.; Stevenson, T.R.; VanderKolk, C.A.

    1987-01-01

    Osteoradionecrosis of the olecranon is an unusual pathologic entity, treated best by debridement and wound closure using vascularized tissue. Local skin is often unavailable for flap design and transposition. The radial forearm flap can be isolated on a proximal vascular pedicle and transposed to cover the wound. In the case presented, healing was brisk and complete, allowing early elbow mobilization. Although the donor site is not easily concealed, no functional impairment results from flap elevation and all full-thickness wounds are confined to the involved extremity

  18. Repair of large palatal fistula using tongue flap

    Directory of Open Access Journals (Sweden)

    Fejjal Nawfal

    2014-01-01

    Full Text Available Large palatal fistulas are a challenging problem in cleft surgery. Many techniques are used to close the defect. The tongue flap is an easy and reproductible procedure for managing this complication. The authors report a case of a large palatal fistula closure with anteriorly based tongue flap.

  19. Regional Myocutaneous Flaps for Head and Neck Reconstruction ...

    African Journals Online (AJOL)

    Regional myocutaneous pedicle flaps (RMF) are known to be relevant in the reconstruction of major head and neck oncologic defects with pectoralis major myocutaneous pedicle flap (PMMC) being the best-known RMF. For over three decades, since first described by Ariyan in 1979, PMMC has continually been used in the ...

  20. The expanded "BAT" flap for treatment of male pattern baldness.

    Science.gov (United States)

    Anderson, R D

    1993-11-01

    A new combination of expanded simultaneous transposition and advancement flaps is reported for the treatment of extensive male pattern baldness. Although vertical transposition and parieto-occipital advancement flaps in themselves are not new, their combination and simultaneous bilateral use combined with the use of expansion is new. The advantages of the expanded bilateral advancement transposition flap procedure are presented, along with the technique and results. The results are predictable, providing a more pleasing result, with a natural immediate temporal recession, avoidance of temporal dog-ears, and desirable anterior-superior direction of hair growth. Although flaps do require surgical skill and training, and there are risks and possible complications involved, the results are achieved in a relatively short time compared with grafting techniques. Flaps also provide the advantages of a full and natural hairline contrasted with the sparse look afforded by multiple grafts. The described procedures are very effective and reliable when properly planned and properly executed.

  1. Orbital floor reconstruction with free flaps after maxillectomy.

    Science.gov (United States)

    Sampathirao, Leela Mohan C S R; Thankappan, Krishnakumar; Duraisamy, Sriprakash; Hedne, Naveen; Sharma, Mohit; Mathew, Jimmy; Iyer, Subramania

    2013-06-01

    Background The purpose of this study is to evaluate the outcome of orbital floor reconstruction with free flaps after maxillectomy. Methods This was a retrospective analysis of 34 consecutive patients who underwent maxillectomy with orbital floor removal for malignancies, reconstructed with free flaps. A cross-sectional survey to assess the functional and esthetic outcome was done in 28 patients who were alive and disease-free, with a minimum of 6 months of follow-up. Results Twenty-six patients had bony reconstruction, and eight had soft tissue reconstruction. Free fibula flap was the commonest flap used (n = 14). Visual acuity was normal in 86%. Eye movements were normal in 92%. Abnormal globe position resulted in nine patients. Esthetic satisfaction was good in 19 patients (68%). Though there was no statistically significant difference in outcome of visual acuity, eye movement, and patient esthetic satisfaction between patients with bony and soft tissue reconstruction, more patients without bony reconstruction had abnormal globe position (p = 0.040). Conclusion Free tissue transfer has improved the results of orbital floor reconstruction after total maxillectomy, preserving the eye. Good functional and esthetic outcome was achieved. Though our study favors a bony orbital reconstruction, a larger study with adequate power and equal distribution of patients among the groups would be needed to determine this. Free fibula flap remains the commonest choice when a bony reconstruction is contemplated.

  2. The isolated perfused human skin flap model: A missing link in skin penetration studies?

    Science.gov (United States)

    Ternullo, Selenia; de Weerd, Louis; Flaten, Gøril Eide; Holsæter, Ann Mari; Škalko-Basnet, Nataša

    2017-01-01

    Development of effective (trans)dermal drug delivery systems requires reliable skin models to evaluate skin drug penetration. The isolated perfused human skin flap remains metabolically active tissue for up to 6h during in vitro perfusion. We introduce the isolated perfused human skin flap as a close-to-in vivo skin penetration model. To validate the model's ability to evaluate skin drug penetration the solutions of a hydrophilic (calcein) and a lipophilic (rhodamine) fluorescence marker were applied. The skin flaps were perfused with modified Krebs-Henseleit buffer (pH7.4). Infrared technology was used to monitor perfusion and to select a well-perfused skin area for administration of the markers. Flap perfusion and physiological parameters were maintained constant during the 6h experiments and the amount of markers in the perfusate was determined. Calcein was detected in the perfusate, whereas rhodamine was not detectable. Confocal images of skin cross-sections shoved that calcein was uniformly distributed through the skin, whereas rhodamine accumulated in the stratum corneum. For comparison, the penetration of both markers was evaluated on ex vivo human skin, pig skin and cellophane membrane. The proposed perfused flap model enabled us to distinguish between the penetrations of the two markers and could be a promising close-to-in vivo tool in skin penetration studies and optimization of formulations destined for skin administration. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Mucoperiosteal Flap Necrosis after Primary Palatoplasty in Patients with Cleft Palate

    Science.gov (United States)

    Cotrina-Rabanal, Omar; Barrenechea-Tarazona, Luis; Vargas-Chanduvi, Roberto; Paredes-Aponte, Luis; Romero-Narvaez, Carolina

    2017-01-01

    Background The prevalence of flap necrosis after palatoplasty in patients with cleft palate. The prevalence of mucoperiosteal flap necrosis after palatoplasty remains unknown, and this complication is rare. This event is highly undesirable for both the patient and the surgeon. We present here a new scale to evaluate the degree of hypoplasia of the palate and identify patients with cleft palate at high risk for the development of this complication. Methods In this case series, a 20-year retrospective analysis (1994–2014) identified patients from our records (medical records and screening day registries) with nonsyndromic cleft palate who underwent operations at 3 centers. All of these patients underwent operations using 2-flap palatoplasty and also underwent a physical examination with photographs and documentation of the presence of palatal flap necrosis after primary palatoplasty. Results Palatal flap necrosis was observed in 4 cases out of 1,174 palatoplasties performed at these centers. The observed prevalence of palatal flap necrosis in these groups was 0.34%. Conclusions The prevalence of flap necrosis can be reduced by careful preoperative planning, and prevention is possible. The scale proposed here may help to prevent this complication; however, further studies are necessary to validate its utility. PMID:28573096

  4. Mucoperiosteal Flap Necrosis after Primary Palatoplasty in Patients with Cleft Palate

    Directory of Open Access Journals (Sweden)

    Percy Rossell-Perry

    2017-05-01

    Full Text Available BackgroundThe prevalence of flap necrosis after palatoplasty in patients with cleft palate. The prevalence of mucoperiosteal flap necrosis after palatoplasty remains unknown, and this complication is rare. This event is highly undesirable for both the patient and the surgeon. We present here a new scale to evaluate the degree of hypoplasia of the palate and identify patients with cleft palate at high risk for the development of this complication.MethodsIn this case series, a 20-year retrospective analysis (1994–2014 identified patients from our records (medical records and screening day registries with nonsyndromic cleft palate who underwent operations at 3 centers. All of these patients underwent operations using 2-flap palatoplasty and also underwent a physical examination with photographs and documentation of the presence of palatal flap necrosis after primary palatoplasty.ResultsPalatal flap necrosis was observed in 4 cases out of 1,174 palatoplasties performed at these centers. The observed prevalence of palatal flap necrosis in these groups was 0.34%.ConclusionsThe prevalence of flap necrosis can be reduced by careful preoperative planning, and prevention is possible. The scale proposed here may help to prevent this complication; however, further studies are necessary to validate its utility.

  5. An international comparison of reimbursement for DIEAP flap breast reconstruction.

    Science.gov (United States)

    Reid, A W N; Szpalski, C; Sheppard, N N; Morrison, C M; Blondeel, P N

    2015-11-01

    The deep inferior epigastric artery perforator (DIEAP) flap is currently considered the gold standard for autologous breast reconstruction. With the current economic climate and health cutbacks, we decided to survey reimbursement for DIEAP flaps performed at the main international centres in order to assess whether they are funded consistently. Data were collected confidentially from the main international centres by an anonymous questionnaire. Our results illustrate the wide disparity in international DIEAP flap breast reconstruction reimbursement: a unilateral DIEAP flap performed in New York, USA, attracts €20,759, whereas the same operation in Madrid, Spain, will only be reimbursed for €300. Only 35.7% of the surgeons can set up their own fee. Moreover, 85.7% of the participants estimated that the current fees are insufficient, and most of them feel that we are evolving towards an even lower reimbursement rate. In 55.8% of the countries represented, there is no DIEAP-specific coding; in comparison, 74.4% of the represented countries have a specific coding for transverse rectus abdominis (TRAM) flaps. Finally, despite the fact that DIEAP flaps have become the gold standard for breast reconstruction, they comprise only a small percentage of all the total number of breast reconstruction procedures performed (7-15%), with the only exception being Belgium (40%). Our results demonstrate that DIEAP flap breast reconstruction is inconsistently funded. Unfortunately though, it appears that the current reimbursement offered by many countries may dissuade institutions and surgeons from offering this procedure. However, substantial evidence exists supporting the cost-effectiveness of perforator flaps for breast reconstruction, and, in our opinion, the long-term clinical benefits for our patients are so important that this investment of time and money is absolutely essential. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons

  6. Live or Let Die: Epithelial Flap Vitality and Keratocyte Proliferation Following LASEK and Epi-LASIK in Human Donor and Porcine Eyes.

    Science.gov (United States)

    Angunawela, Romesh I; Winkler von Mohrenfels, Christoph; Kumar, Anupma; O'Brart, David P S; Marshall, John

    2011-02-01

    To determine the relationship between epithelial flap vitality and stromal keratocyte proliferation following two epithelial refractive techniques: epi-LASIK and laser epithelial keratomileusis (LASEK). Human corneas were maintained in organ culture and underwent standard -6.00-diopter ablation. Rates of stromal keratocyte proliferation were detected 1 week postoperative using a Ki67 antibody specific to proliferating cells. Images were captured with a laser scanning confocal microscope and analyzed by a masked observer. Epithelial flap vitality was determined with propidium iodide using fresh porcine corneas. Epithelial flaps were created with Gebauer Epikeratome epi-LASIK or alcohol-assisted LASEK method. Flaps treated with 100% alcohol and uninjured corneas were used as controls. The number of proliferating keratocytes was greatest at 1 week in the epi-LASIK corneas (Pvitality was greatest in the epi-LASIK flaps and declined in the LASEK and 100% alcohol flaps (Plive cells. There is also a greater number of proliferating stromal cells following epi-LASIK at 1 week. Based on these in vitro observations, epi-LASIK may result in greater levels of haze compared to LASEK. Copyright 2011, SLACK Incorporated.

  7. Suprafascial versus traditional harvesting technique for free antero lateral thigh flap: A case-control study to assess the best functional and aesthetic result in extremity reconstruction.

    Science.gov (United States)

    Maruccia, Michele; Fallico, Nefer; Cigna, Emanuele; Ciudad, Pedro; Nicoli, Fabio; Trignano, Emilio; Nacchiero, Eleonora; Giudice, Giuseppe; Ribuffo, Diego; Chen, Hung-Chi

    2017-11-01

    Clinical applications of ALT flap have currently extended to extremity (hand and foot) as well as oral cavity reconstruction. In these anatomical areas, the traditional harvesting technique presents a few disadvantages such as bulkiness of the recipient site and potential donor site morbidity including damage to the deep fascia and skin graft adhesions. The purpose of the present study was to compare the functional and aesthetic outcomes of upper and lower extremity reconstruction with either suprafascial or subfascial harvested anterolateral (ALT) flaps. Sixty patients who underwent hand or foot reconstruction with an ALT flap between January 2013 and January 2015 were included in the study (34 flaps elevated on a subfascial plane and 26 on a suprafascial plane). Group 1 (subfascial harvested ALT flap) was composed of 23 male and 11 female patients with an average age of 53.4 years (range, 36-72 years). Group 2 (suprafascial harvested ALT flap) was composed of 18 male and 8 female patients with an average age of 48.7 years (range, 32-69 years). Surgical indication was tumor resection for 20 patients in group 1 and 16 patients in group 2, chronic ulcer for 8 patients in group 1 and 6 patients in group 2, and trauma for 6 patients in group 1 and 4 patients in group 2. Complications were documented. Aesthetic outcomes were considered in terms of bulkiness of the recipient site, subsequent request for a debulking procedure, and donor site morbidity. Donor site scars were evaluated for cosmesis using a modified Hollander Wound Evaluation Scale (HWES). Skin grafts outcomes were assessed according to the modified Vancouver Scar Scale (VSS). Functional outcome at the recipient site was measured using the Enneking functional outcome score (ESS). Total range of motion (ROM) was recorded. All flaps were successfully elevated with at least one viable perforator with both approaches. The survival rates of suprafascial and subfascial harvested ALT flaps were 96.2 and 97

  8. Plantar flaps based on perforators of the plantar metatarsal/common digital arteries.

    Science.gov (United States)

    Valentin, Georgescu Alexandru; Rodica, Matei Ileana; Manuel, Llusa

    2014-09-01

    Because of the unique characteristics of its integument, the affirmation "replacing like with like" becomes more than evident in the reconstruction of defects of the ultraspecialized plantar skin. But, the paucity of local resources, and especially in the forefoot, transforms this attempt in a very challenging problem. Many techniques, including skin grafts and various types of flaps were used in the management of defects in the forefoot. We present a new useful flap in the reconstruction of skin defects in the forefoot, based on small perforator vessels originating either from the plantar metatarsal arteries or plantar common digital arteries. Starting with June 2011, this flap was performed, as plantar transposition perforator flap, plantar propeller flap, or plantar propeller perforator plus flap, in seven patients with ulcers over the plantar forefoot. During a follow-up of 7 to 17 months (mean, 9.8 months), the local evolution regarding flap integration, pain, relapse, sensitive recovery, donor site, and footwear quality was analyzed. We registered a 100% survival rate of the flaps, with delayed healing in only one case. The gait resumption was possible after 6 weeks in all cases. This new flap, based on small perforator vessels from the plantar metatarsal or common digital arteries, and which provides a good, stable, and sensory recovery, seems to be a promising method in the reconstruction of plantar skin defects over the metatarsal heads. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Obesity Should Not Prevent from TRAM Flap Breast Reconstruction in Developing Countries.

    Science.gov (United States)

    Alipour, Sadaf; Omranipour, Ramesh; Akrami, Rahim

    2015-12-01

    Transverse rectus abdominis musculocutaneous (TRAM) flap is the most common procedure performed for breast reconstruction after mastectomy for breast cancer. Obesity is a relative contraindication, and complex modifications have been proposed in the pedicled technique for obese patients. We studied ischemic complications in our patients to investigate the effect of body weight on the outcome of TRAM flap breast reconstruction. Pertinent data from medical records of patients receiving a TRAM flap surgery from 1986 to 2011 were extracted. Patients were divided into three groups based on the body mass index (BMI): normal (obese (>30 kg/m(2)). Flap necrosis is defined as any visible nonviable tissue in the reconstructed breast. It was observed that 117 patients had received TRAM flap reconstruction. Fifty-eight patients were excluded. Of the remaining 59 cases, 24 had normal BMI, 21 were overweight, and 14 were obese. No patient was found to develop flap necrosis. Outcome of TRAM flap breast reconstruction in obese patients is similar to nonobese patients. No major necrosis in need of reoperation was identified in the studied obese patients. It was concluded that categorizing obesity as a relative contraindication to TRAM flap breast reconstruction should be revisited based on larger cohort studies.

  10. Preoperative TRAM free flap volume estimation for breast reconstruction in lean patients.

    Science.gov (United States)

    Minn, Kyung Won; Hong, Ki Yong; Lee, Sang Woo

    2010-04-01

    To obtain pleasing symmetry in breast reconstruction with transverse rectus abdominis myocutaneous (TRAM) free flap, a large amount of abdominal flap is elevated and remnant tissue is trimmed in most cases. However, elevation of abundant abdominal flap can cause excessive tension in donor site closure and increase the possibility of hypertrophic scarring especially in lean patients. The TRAM flap was divided into 4 zones in routine manner; the depth and dimension of the 4 zones were obtained using ultrasound and AutoCAD (Autodesk Inc., San Rafael, CA), respectively. The acquired numbers were then multiplied to obtain an estimate of volume of each zone and the each zone volume was added. To confirm the relation between the estimated volume and the actual volume, authors compared intraoperative actual TRAM flap volumes with preoperative estimated volumes in 30 consecutive TRAM free flap breast reconstructions. The estimated volumes and the actual elevated volumes of flap were found to be correlated by regression analysis (r = 0.9258, P Autodesk Inc.) allow the authors to attain the precise volume desired for elevation. This method provides advantages in terms of minimal flap trimming, easier closure of donor sites, reduced scar widening and symmetry, especially in lean patients.

  11. Dual-dermal-barrier fashion flaps for the treatment of sacral pressure sores.

    Science.gov (United States)

    Hsiao, Yen-Chang; Chuang, Shiow-Shuh

    2015-02-01

    The sacral region is one of the most vulnerable sites for the development of pressure sores. Even when surgical reconstruction is performed, there is a high chance of recurrence. Therefore, the concept of dual-dermal-barrier fashion flaps for sacral pressure sore reconstruction was proposed. From September 2007 to June 2010, nine patients with grade IV sacral pressures were enrolled. Four patients received bilateral myocutaneous V-Y flaps, four patients received bilateral fasciocutaneous V-Y flaps, and one patient received bilateral rotation-advanced flaps for sacral pressure reconstruction. The flaps were designed based on the perforators of the superior gluteal artery in one patient's reconstructive procedure. All flaps' designs were based on dual-dermal-barrier fashion. The mean follow-up time was 16 months (range = 12-25). No recurrence was noted. Only one patient had a complication of mild dehiscence at the middle suture line, occurring 2 weeks after the reconstructive surgery. The dual-dermal fashion flaps are easily duplicated and versatile. The study has shown minimal morbidity and a reasonable outcome.

  12. Reconstruction of hand contracture by reverse ulnar perforator flap

    Directory of Open Access Journals (Sweden)

    Cengiz Eser

    2016-04-01

    Full Text Available Hand burn scar contractures affect patients in aesthetic and functional aspects. After releasing these scars, the defects should be repaired. The reconstruction methods include primary suturation, Z plasty, skin grafting, local or free flaps, etc. All methods have their own advantages and disadvantages. One of the most useful flaps is the reverse ulnar perforator flap. We performed a two-staged procedure for repairing a post-burn contracture release defect in a 40-year-old male. In the first stage we applied reverse ulnar perforator flap for the hand defect, and ulnar artery and vein repair in the second stage. In conclusion, this two-staged procedure is a non-primary but useful option for hand and finger defects and prevents major vascular structure damage of the forearm. [Hand Microsurg 2016; 5(1.000: 40-43

  13. Reconstruction of palatal defect using mucoperiosteal hinge flap and pushback palatoplasty.

    Science.gov (United States)

    Lee, S I; Lee, H S; Hwang, K

    2001-11-01

    This article describes a simple, new surgical technique to provide a complete two-layer closure of palatal defect resulting from a surgical complication of trans palatal resection of skull base chordoma. The nasal layer was reconstructed with triangular shape oral mucoperiosteal turn over hinge flap based on anterior margin of palatal defect and rectangular shaped lateral nasal mucosal hinge flaps. The oral layer was reconstructed with conventional pushback V-Y advancement 2-flaps palatoplasty. Each layer of the flaps were secured with two key mattress suture for flap coaptation. This technique has some advantages: simple, short operation time, one-stage procedure, no need of osteotomy. It can close small- to medium-sized palatal defect of palate or wide cleft palate and can prevent common complication of oronasal fistula, which could be caused by tension.

  14. Flap testing on the rotating test rig in the INDUFLAP project

    DEFF Research Database (Denmark)

    Barlas, Athanasios; Aagaard Madsen, Helge; Enevoldsen, Karen

    Tests of a prototype Controllable Rubber Trailing Edge Flap (CRTEF) are performed on the rotating test rig at the Risø campus of DTU. The general description and objectives are presented, along with an overview of sensors on the setup and the test cases. The post-processing of data is discussed...

  15. Airfoil-Wake Modification with Gurney Flap at Low Reynolds Number

    Science.gov (United States)

    Gopalakrishnan Meena, Muralikrishnan; Taira, Kunihiko; Asai, Keisuke

    2018-04-01

    The complex wake modifications produced by a Gurney flap on symmetric NACA airfoils at low Reynolds number are investigated. Two-dimensional incompressible flows over NACA 0000 (flat plate), 0006, 0012 and 0018 airfoils at a Reynolds number of $Re = 1000$ are analyzed numerically to examine the flow modifications generated by the flaps for achieving lift enhancement. While high lift can be attained by the Gurney flap on airfoils at high angles of attack, highly unsteady nature of the aerodynamic forces are also observed. Analysis of the wake structures along with the lift spectra reveals four characteristic wake modes (steady, 2S, P and 2P), influencing the aerodynamic performance. The effects of the flap over wide range of angles of attack and flap heights are considered to identify the occurrence of these wake modes, and are encapsulated in a wake classification diagram. Companion three-dimensional simulations are also performed to examine the influence of three-dimensionality on the wake regimes. The spanwise instabilities that appear for higher angles of attack are found to suppress the emergence of the 2P mode. The use of the wake classification diagram as a guidance for Gurney flap selection at different operating conditions to achieve the required aerodynamic performance is discussed.

  16. Reverse saphenous conduit flap in small animals: Clinical applications and outcomes

    Directory of Open Access Journals (Sweden)

    Ross C. Elliott

    2014-08-01

    Full Text Available Due to the lack of skin elasticity defects of the distal hind limb can be a challenge to close. This article assesses a well-described, but completely under-used technique for closure of wounds on the distal tarsus. The technique was used with good success in six cases presenting to the Bryanston Veterinary Hospital with a wide range of underlying pathology ranging from trauma to neoplastic disease of the tarsus. All six cases were treated with a reverse saphenous conduit flap and two of them underwent radiation therapy with no adverse side effects. All cases showed excellent results with a very low degree of flap necrosis that never exceeded 15% of the total flap area. This skin flap provides an excellent treatment method that is reliable in closure of defects of the distal tarsus with few adverse effects. To the author’s knowledge there has been only one previously published report on the clinical use of this type of skin flap,even though the flap is well described in most texts.

  17. Aerodynamic characteristics of NACA 4412 airfoil section with flap in extreme ground effect

    Directory of Open Access Journals (Sweden)

    Alex E. Ockfen

    2009-09-01

    Full Text Available Wing-in-Ground vehicles and aerodynamically assisted boats take advantage of increased lift and reduced drag of wing sections in the ground proximity. At relatively low speeds or heavy payloads of these craft, a flap at the wing trailing-edge can be applied to boost the aerodynamic lift. The influence of a flap on the two-dimensional NACA 4412 airfoil in viscous ground-effect flow is numerically investigated in this study. The computational method consists of a steady-state, incompressible, finite volume method utilizing the Spalart-Allmaras turbulence model. Grid generation and solution of the Navier-Stokes equations are completed using computer program Fluent. The code is validated against published experimental and numerical results of unbounded flow with a flap, as well as ground-effect motion without a flap. Aerodynamic forces are calculated, and the effects of angle of attack, Reynolds number, ground height, and flap deflection are presented for a split and plain flap. Changes in the flow introduced with the flap addition are also discussed. Overall, the use of a flap on wings with small attack angles is found to be beneficial for small flap deflections up to 5% of the chord, where the contribution of lift augmentation exceeds the drag increase, yielding an augmented lift-to-drag ratio.

  18. Comparative study of 2 commissural dorsal flap techniques for the treatment of congenital syndactyly.

    Science.gov (United States)

    Mallet, Cindy; Ilharreborde, Brice; Jehanno, Pascal; Litzelmann, Estelle; Valenti, Philippe; Mazda, Keyvan; Penneçot, Georges-François; Fitoussi, Franck

    2013-03-01

    Many commissural reconstruction techniques have been described for the treatment of syndactyly. This study is the first to compare long-term results of 2 commissural dorsal flap procedures (T-flap and omega-flap). Fifty-nine web-spaces in 39 patients, operated on between 1991 and 2008, were retrospectively analyzed. Thirty-six T-flap and 23 omega-flap procedures were performed using full-thickness skin graft in every case for digital resurfacing. Factors that could affect the long-term outcome were collected, including development of web-creep, clinodactyly, and flexion contracture. Patients were reviewed with a mean follow-up of 5 years and 8 months. Preoperative complexity of syndactyly influenced the development of clinodactyly and flexion contracture. Among the patients who developed clinodactyly, 96% had surgery for complex syndactyly. No difference was found between the 2 flap methods concerning digital deformation and mobility. However, web-creep occurred more frequently after T-flap than after omega-flap procedures (17% vs. 5%). The combination of either dorsal commissural T-flaps or omega-flaps with full-thickness graft to resurface digits is a reliable technique for the treatment of syndactyly with satisfactory functional and cosmetic results. Long-term results are not influenced by the type of flap. Nevertheless, the omega-flap technique, using 2 triangular lateral-palmar flaps, avoids use of skin graft to cover lateral-palmar aspects of the new commissure, consequently reducing the incidence of web-creep. In cases of syndactyly, the primary prognostic factor is whether the patient has simple or complex syndactyly. In complex syndactyly, the risk of long-term unfavorable results is higher. When complex complicated syndactyly is involved, postoperative complication rates increase. Level III.

  19. Semi-active control of helicopter vibration using controllable stiffness and damping devices

    Science.gov (United States)

    Anusonti-Inthra, Phuriwat

    Semi-active concepts for helicopter vibration reduction are developed and evaluated in this dissertation. Semi-active devices, controllable stiffness devices or controllable orifice dampers, are introduced; (i) in the blade root region (rotor-based concept) and (ii) between the rotor and the fuselage as semi-active isolators (in the non-rotating frame). Corresponding semi-active controllers for helicopter vibration reduction are also developed. The effectiveness of the rotor-based semi-active vibration reduction concept (using stiffness and damping variation) is demonstrated for a 4-bladed hingeless rotor helicopter in moderate- to high-speed forward flight. A sensitivity study shows that the stiffness variation of root element can reduce hub vibrations when proper amplitude and phase are used. Furthermore, the optimal semi-active control scheme can determine the combination of stiffness variations that produce significant vibration reduction in all components of vibratory hub loads simultaneously. It is demonstrated that desired cyclic variations in properties of the blade root region can be practically achieved using discrete controllable stiffness devices and controllable dampers, especially in the flap and lag directions. These discrete controllable devices can produce 35--50% reduction in a composite vibration index representing all components of vibratory hub loads. No detrimental increases are observed in the lower harmonics of blade loads and blade response (which contribute to the dynamic stresses) and controllable device internal loads, when the optimal stiffness and damping variations are introduced. The effectiveness of optimal stiffness and damping variations in reducing hub vibration is retained over a range of cruise speeds and for variations in fundamental rotor properties. The effectiveness of the semi-active isolator is demonstrated for a simplified single degree of freedom system representing the semi-active isolation system. The rotor

  20. Surgical revirgination: Four vaginal mucosal flaps for reconstruction of a hymen

    Directory of Open Access Journals (Sweden)

    Hemant A Saraiya

    2015-01-01

    Full Text Available Introduction: Over centuries, virginity has been given social, religious and moral importance. It is widely believed as a state of a female who has never engaged in sexual intercourse, and her hymen is intact. Hymenoplasty for torn hymen is carried out not only for the sake of cultural and religious traditions but also for the social status and interpersonal relationships. Materials and Methods: 2.5 cm long and 1 cm wide four vaginal mucosal flaps were raised from the anterior vaginal wall just behind labia minora. Two flaps were based proximally, and their two opposing flaps were based distally. These flaps were overlapped in a crisscross fashion and were sutured with 5/0 Polyglactin (Vicryl® sutures leaving no area raw. The donor area was closed primarily. When some remains of a torn hymen were found, one to three vaginal mucosal flaps were added to its remains as per the need for reconstruction. Results: We operated upon 11 patients. In nine cases, the hymen was reconstructed with four flaps. In remaining two, it was reconstructed from the remains using vaginal mucosal flaps. All flaps healed without any infection or disruption. Sutures got absorbed in 25-35 days. In all cases, this newly constructed barrier broke with only moderate pressure at the time of penetrative sex serving the purpose of the surgery completely. Conclusion: Erasing evidence of the sexual history simply by ′Surgical Revirgination′ is extremely important to women contemplating marriage in cultures where a high value is placed on virginity.

  1. Reconstruction of fingers after electrical injury using lateral tarsal artery flap

    Directory of Open Access Journals (Sweden)

    Zhang MH

    2017-07-01

    Full Text Available Minghua Zhang, Mitao Huang, Pihong Zhang, Pengfei Liang, Licheng Ren, Jizhang Zeng, Jie Zhou, Xiong Liu, Tinghong Xie, Xiaoyuan Huang Department of Burns Reconstruction Surgery, Xiangya Hospital, Central South University, Changsha, Hunan, People’s Republic of China Objective: Electrical injuries to the fingers account for the majority of total severe burns that occur each year. While several types of flaps have been used in covering finger defects, all have limitations or disadvantages. The purpose of this study was to introduce our clinical experiences of using the lateral tarsal artery (LTA flap to successfully restore fingers after electrical injury.Patients and methods: From 2005 to 2012, 10 patients with 14 severe electrical burns to their fingers, including six thumbs and four index and four middle fingers, were treated with LTA flap. The wound size ranged from 2.0×3.0 cm to 3.5×5.0 cm. The flap with free tendon graft was used to repair the tendon defect in four cases, free nerve graft was used to repair the feeling defect in two cases, and the flap with nerve was used to repair the feeling defect in two cases. All the patients were followed up for 3 months to 2 years.Results: All skin flaps adhered successfully and there were no complications. All patients were satisfied with the esthetic appearance and functional outcome of the finger reconstruction.Conclusion: LTA flap is a reliable method to restore fingers after severe electrical injuries. Keywords: electrical injuries to fingers, lateral tarsal artery flap

  2. Application of Indocyanine Green in Flap Surgery: A Systematic Review.

    Science.gov (United States)

    Li, Ke; Zhang, Zheng; Nicoli, Fabio; D'Ambrosia, Christopher; Xi, Wenjing; Lazzeri, Davide; Feng, Shaoqing; Su, Weijie; Li, Hua; Ciudad, Pedro; Tremp, Mathias; Zhang, Yi Xin

    2018-02-01

     The vascularization of the distal portions of transferred tissue represents the most critical factor in the success of reconstructive surgery. In recent years, indocyanine green (ICG) fluorescence imaging techniques have been applied during surgery to evaluate flap perfusion. However, this investigation has found that there is little consensus regarding the standard dose of ICG as well as the pre-operative requirements of ICG allergy testing. The aim of this study is to summarize the applications of ICG to tissue transfers and safe dosing practices and to provide insight to the possible adverse effects of ICG on flap surgery with the goal of helping clinicians apply ICG safely and efficiently to tissue transfer procedures.  A literature search was performed using, Wiley InterScience, and Springer with the key words, 'Flap,' 'indocyanine green,' 'surgery,' and related mesh words for all publications between 2005 and 2015. Title and abstract screening was performed using predefined in- and exclusion criteria.  Seventy-three articles were included. These were classified as "application of ICG in flap surgery" and "the security of applying ICG in flap surgery".  ICG fluorescence imaging preoperatively facilitates the detection of perforators in tissue flaps with thickness <20 mm, aids in the evaluation of flap microcirculation and perfusion, and allows surgeons to select dominant cutaneous nerves while evaluating the quality of vascular anastomoses and locating thromboses. The literature also concluded that potential allergic reactions to ICG should be taken into consideration. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. The anatomy of forearm free flap phalloplasty for transgender surgery.

    Science.gov (United States)

    Kim, S; Dennis, M; Holland, J; Terrell, M; Loukas, M; Schober, J

    2018-03-01

    Transgender surgeries are becoming more frequent and visual interpretation of anatomy is essential for both surgeons and patients. Since the forearm free flap phalloplasty was introduced in 1984, it has been known to provide reliable cosmetic and functional results for transitioning men compared with phalloplasty by different flaps. Surgical text descriptions were enhanced by the creation of new anatomic illustrations. The forearm free flap consists of the anterior forearm skin, subcutaneous tissue, fascia containing the radial artery as the perforator and its venae comitantes, cephalic and basilic veins, and lateral and medial antebrachial cutaneous nerves are demonstrated in relation to the surgically derived flap. Song's forearm free flap phalloplasty requires two surgical stages with a three-month interval between the stages: prelamination of a neourethra and construction of a neophallus. The neophallus created by forearm flap phalloplasty is reported to achieve acceptable aesthetical and psychological satisfaction, appropriate size and shape, and satisfying sexual intercourse. Despite increasing experiences in gender confirming surgery with modifications made by many authors, urethral complications including fistula and/or stricture formation are the leading causes of reoperation. The poor esthetic outcome of the forearm donor site and a decrease in rigidity of the neophallus are the main limitations. Illustrations of anatomy help inform surgical choice and understanding of risks and benefits by patients. The anatomy of the free forearm flap phalloplasty supports creation of a neophallus for transsexual anatomy revision. Clin. Anat. 31:145-151, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  4. Optimization of breast reconstruction results using TMG flap in 30 cases: Evaluation of several refinements addressing flap design, shaping techniques, and reduction of donor site morbidity.

    Science.gov (United States)

    Nickl, Stefanie; Nedomansky, Jakob; Radtke, Christine; Haslik, Werner; Schroegendorfer, Klaus F

    2018-01-31

    The transverse myocutaneous gracilis (TMG) flap is a widely used alternative to abdominal flaps in autologous breast reconstruction. However, secondary procedures for aesthetic refinement are frequently necessary. Herein, we present our experience with an optimized approach in TMG breast reconstruction to enhance aesthetic outcome and to reduce the need for secondary refinements. We retrospectively analyzed 37 immediate or delayed reconstructions with TMG flaps in 34 women, performed between 2009 and 2015. Four patients (5 flaps) constituted the conventional group (non-optimized approach). Thirty patients (32 flaps; modified group) underwent an optimized procedure consisting of modified flap harvesting and shaping techniques and methods utilized to reduce denting after rib resection and to diminish donor site morbidity. Statistically significant fewer secondary procedures (0.6 ± 0.9 versus 4.8 ± 2.2; P < .001) and fewer trips to the OR (0.4 ± 0.7 versus 2.3 ± 1.0 times; P = .001) for aesthetic refinement were needed in the modified group as compared to the conventional group. In the modified group, 4 patients (13.3%) required refinement of the reconstructed breast, 7 patients (23.3%) underwent mastopexy/mammoplasty or lipofilling of the contralateral breast, and 4 patients (13.3%) required refinement of the contralateral thigh. Total flap loss did not occur in any patient. Revision surgery was needed once. Compared to the conventional group, enhanced aesthetic results with consecutive reduction of secondary refinements could be achieved when using our modified flap harvesting and shaping techniques, as well as our methods for reducing contour deformities after rib resection and for overcoming donor site morbidities. © 2017 Wiley Periodicals, Inc.

  5. RECONSTRUCTION OF POST ELECTRIC BURN DEFECTS OF UPPER LIMB WITH DIFFERENT FLAPS

    Directory of Open Access Journals (Sweden)

    Satyajit

    2015-08-01

    Full Text Available INTRODUCTION: P ost electric burn defects are difficult to manage due to deep injury involving all the structures up to bony level. A good vascularized flap is required to resurface the defect for preventing the complication and for reconstruction of involved structures. AIM: Resurfacing the post electric burn defect with different flaps according to need of the defect. MATERIAL AND METHOD: All patients of electric burn hand and fore arm defect admitted to burn, p lastic and reconstructi ve department of SCB Medical College &hospital, Cuttack between January 2012 to December 2012 were included in the study. During this period the patients were followed up at weekly interval for first 2 month, then at 1 monthly interv al for next 6 - 8 month. OBSERVATION: Out of 40 cases of post electric burn forearm and hand reconstruction, 10 cases underwent groin flap cover, 6 cases underwent abdominal flap cover, 5 cases underwent cross finger flap cover 5 cases underwent free antero lateral thigh flap cover, 4 cases underwent free latissimus dorsi flap cover, 5 cases underwent first dorsal metacarpal artery flap cover, 5 cases reverse radial forearm flap cover. All the defects were resurfaced successfully with flaps. Four had marginal necrosis and six had wound infection. Eventually all flaps settled well without further intervention. Due to involvement of all important tendons & nerves, functional outcome is guarded. DISCUSSION: Hand and forearm are most commonly and most severely aff ected in electric burn injury because they are mostly first part of body to come in contact with electric circuit. Even though at initial part the injury appears to be superficial, deepe r structures like bone, tendon and neurovascular bundles are affected requiring flap cover for future reconstruction of these structures to get functional and sensate hand. CONCLUSION: Reconstruction of post electric burn defect of distal forearm and hand represents great challenge due to

  6. Versatality of supraclavicular flap in neck, face, and upper chest region coverage

    International Nuclear Information System (INIS)

    Almas, D.; Masood, T.; Dar, M.F.; Noman, B.

    2015-01-01

    The objective is to analyze the utility of the island supraclavicular flap in a region where skin graft cannot be used and free flap is not feasible. We assessed complications and functional outcomes. Study Design: Prospective descriptive study. Place and Duration of Study: The study was done at plastic and reconstructive surgery department CMH Rawalpindi during the period of 03 year from October 2011 to October 2014. Material and Patients: An island supraclavicular artery flap was used to reconstruct oncologic, and post burn neck contractures release defects. 30 patients were included in the study. Doppler probe was used to help with localization of vascular pedicle. All the patients with scarring in both shoulder regions, history of radiation to neck and undergoing radical neck dissection were excluded. Results: A total of 30 patients were included 20 (66.6%) male and 10 (33.3%) were female. Oncologicre section was followed by immediate reconstruction with island supraclavicular artery flap. Post burn contractures were released and covered by a pedicled supraclavicular artery flap. The recipient sites were neck, face, oral and upper chest region. The average harvest time was 1 and half hour. Donor site was closed primarily in 22 (73.3%) while 8 (26.6%) require skin grafting. Post burn contractures needed scar management with intralesional steroid, pressure garments and scar revision with Z-plasty in 4(13.3%) cases. 1 (3.3%) flap failed completely and the defect was covered with a skin graft. We had 01 (3.3%) mortality due to respiratory obstruction, despite adequate flap perfusion for 24 hours. Minor complications included, partial flap loss, seroma, and haematoma formation. In addition hypertrophied scar, spreading scar and keloid formation occurred at the donor site 18 (60%). Conclusion: Island supraclavicular artery flap with an easy learning curve is a reliable flap. It has a good colour and texture match with minimal donor site morbidity. It is an excellent

  7. Complications Following Autologous Latissimus Flap Breast Reconstruction

    Directory of Open Access Journals (Sweden)

    Mufid Burgić

    2010-02-01

    Full Text Available Use of an autologous latissimus flap in breast reconstruction accounts for a supple and natural look of reconstructed breast. Most common postoperative complication, seroma, became more of a rule then an exception when it comes to postoperative evaluation of the patients who underwent this reconstructive procedure. A retrospective study analysing and evaluating different complication rates in 20 patients who underwent breast reconstruction by autologous latissimus flap, was conducted. All patients included in the study were operated at the Department of plastic surgery of Hôpital Civil in Strasbourg, France, between 1996 and 2008. The complication rates were noted as follows: seroma in 19 of our 20 patients (95%, late hypertrophic scarring in 3 patients (15%, postoperative surgical site hematoma in 3 patients (15%, and 2 patients (10% presented postoperative chronic back pain. Different options used in seroma treatment and prevention (subcutaneous-fascia anchor sutures of donor site, application of corticosteroids by injection into donor site postoperatively, passive drainage can reduce seroma formation and thus overall complication rates, leading to much faster patient’s recovery time and return to normal daily activities.

  8. The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome.

    Science.gov (United States)

    Goussous, Iyad A; El-Agha, Mohamed-Sameh; Awadein, Ahmed; Hosny, Mohamed H; Ghaith, Alaa A; Khattab, Ahmed L

    2017-01-01

    The purpose of this study was to determine the effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis (LASIK). This is a prospective controlled non-randomized, institutional study. Patients underwent either epi-LASIK with mitomycin (advanced surface ablation [ASA]), thin-flap LASIK (90 µm head), or thick-flap LASIK (130 µm head). In ASA, the Moria Epi-K hydroseparator was used. LASIK flaps were created using the Moria M-2 mechanical microkeratome. The corneal hysteresis (CH) and corneal resistance factor (CRF) were measured preoperatively and 3 months after surgery, using the Ocular Response Analyzer ® . Ten patients (19 eyes) underwent ASA, 11 patients (16 eyes) underwent thin-flap LASIK, and 11 patients (16 eyes) underwent thick-flap LASIK. The mean preoperative CH was 10.47±0.88, 10.52±1.4, and 11.28±1.4 mmHg ( p =0.043), respectively, decreasing after surgery by 1.75±1.02, 1.66±1.00, and 2.62±1.03 mmHg ( p =0.017). The mean reduction of CH per micron of central corneal ablation was 0.031, 0.023, and 0.049 mmHg/µm ( p =0.005). Mean preoperative CRF was 10.11±1.28, 10.34±1.87, and 10.62±1.76 mmHg ( p =0.66), decreasing after surgery by 2.33±1.35, 2.77±1.03, and 2.92±1.10 mmHg ( p =0.308). The mean reduction of CRF per micron of central corneal ablation was 0.039, 0.040, and 0.051 mmHg/µm ( p =0.112). Thick-flap LASIK caused a greater reduction of CH and CRF than thin-flap LASIK and ASA, although this was statistically significant only for CH. ASA and thin-flap LASIK were found to be biomechanically similar.

  9. Reliability of Free Radial Forearm Flap for Tongue Reconstruction Following Oncosurgical Resection

    Directory of Open Access Journals (Sweden)

    Gaurab Ranjan Chaudhuri

    2015-08-01

    Full Text Available Introduction Primary closure following oncosurgical resection of carcinoma tongue has been found to compromise tongue function in regards to speech and swallowing very badly. In contrast, reconstruction of tongue with free radial forearm flap following oncosurgical resection has shown promising functional outcome. Materials and Methods Thirteen patients (ten male and three female with squamous cell carcinoma involving anterior 2/3rd of tongue had undergone either hemiglossectomy or subtotal glossectomy. Reconstruction was done with free radial forearm flap following oncosurgical resection and neck dissection. All of them received postoperative radiotherapy. Follow-up ranged from 2 months to 2 years. The age of the patients ranged between 32 and 65 years. Flap dimension ranged from 7x6 cm to 10x8 cm. Vascular anastomosis performed in an end-to-end manner with 8-0 Ethilon® under loupe magnifiacation. Results Venous congestion occurred in one patient after 48 hours postoperatively and the flap underwent complete necrosis on postoperative day 5. Postoperative hematoma was found in one patient within first 24 hours of reconstruction. Re-exploration was done immediately, blood clots were removed. No fresh bleeding point was seen and the flap survived. In this series, 12 out of 13 flaps survived completely (92%. Conclusion The free radial forearm flap has become a workhorse flap in head and reconstruction due to its lack of extra bulk, relative ease of dissection, long vascular pedicle, good calibre vessels, malleability and minimal donor site morbidity. Furthermore its low flap loss and complication rate offer the best choice for tongue reconstruction.

  10. Facial reconstruction with a unique osteomyocutaneous DCIA perforator flap variant: a case report.

    Science.gov (United States)

    Wechselberger, G; Schwaiger, K; Hachleitner, J; Oberascher, G; Ensat, F; Larcher, L

    Anatomical variance of the deep circumflex iliac artery is of high clinical value in facial reconstruction using a deep circumflex iliac artery perforator (DCIAP) flap. We present the case of a 76-year-old woman treated with an osteomyocutaneous DCIAP flap variant for facial reconstruction. We also review here the literature on DCIA perforator flaps and the different anatomical variances, which might bring clinical benefits. The observed anatomy in our patient offered the possibility to raise a free flap variant with high mobility of a large skin paddle and a long vascular pedicle combined with a variable osteomuscular portion. The characteristics of the flap thus raised help overcome the disadvantages of the conventional DCIAP flap and offer excellent options for facial reconstruction.

  11. A Comparative Study of Simulated and Measured Gear-Flap Flow Interaction

    Science.gov (United States)

    Khorrami, Mehdi R.; Mineck, Raymond E.; Yao, Chungsheng; Jenkins, Luther N.; Fares, Ehab

    2015-01-01

    The ability of two CFD solvers to accurately characterize the transient, complex, interacting flowfield asso-ciated with a realistic gear-flap configuration is assessed via comparison of simulated flow with experimental measurements. The simulated results, obtained with NASA's FUN3D and Exa's PowerFLOW® for a high-fidelity, 18% scale semi-span model of a Gulfstream aircraft in landing configuration (39 deg flap deflection, main landing gear on and off) are compared to two-dimensional and stereo particle image velocimetry measurements taken within the gear-flap flow interaction region during wind tunnel tests of the model. As part of the bench-marking process, direct comparisons of the mean and fluctuating velocity fields are presented in the form of planar contour plots and extracted line profiles at measurement planes in various orientations stationed in the main gear wake. The measurement planes in the vicinity of the flap side edge and downstream of the flap trailing edge are used to highlight the effects of gear presence on tip vortex development and the ability of the computational tools to accurately capture such effects. The present study indicates that both computed datasets contain enough detail to construct a relatively accurate depiction of gear-flap flow interaction. Such a finding increases confidence in using the simulated volumetric flow solutions to examine the behavior of pertinent aer-odynamic mechanisms within the gear-flap interaction zone.

  12. The effects of epinephrine and dobutamine on skin flap viability in rats

    DEFF Research Database (Denmark)

    Krammer, Caspar W; Ibrahim, Rami Mossad; Hansen, Tom G

    2015-01-01

    BACKGROUND: Intraoperative reduction in arterial pressure may cause hypoperfusion of skin flaps, which may increase the risk of flap failure. There is no international consensus regarding the use of vasoactive or inotropic agents to restore or maintain flap perfusion. The purpose of this study...

  13. Human and Autologous Adipose-derived Stromal Cells Increase Flap Survival in Rats Independently of Host Immune Response

    DEFF Research Database (Denmark)

    Toyserkani, Navid Mohamadpour; Jensen, Charlotte Harken; Andersen, Ditte Caroline

    2018-01-01

    evaluated after 7 days. RESULTS: The mean survival rates for SVF treatment regardless of human or autologous origin were significantly increased as compared with the control group. Adipose stem/stromal cell and SVF lysate injection did not increase flap survival. Vessel density was increased for human...... injections lead to increased vessel density, but it did not necessarily lead to increased flap survival. Further research should elaborate which molecular events make SVF treatment more efficacious than ASC....

  14. [Contribution of the scrotal flap for the coverage of ischial and perineal pressure ulcers].

    Science.gov (United States)

    Vantomme, M; Viard, R; Aimard, R; Vincent, P-L; Comparin, J-P; Voulliaume, D

    2018-04-11

    The ischiatric pressure sore is a common pathology in rehabilitated spinal cord injured people, despite careful prevention. Medical treatment by discharge and directed healing is not always sufficient and surgery using local musculocutaneous flaps is often essential. Unfortunately, recidivism is frequent and the availability of local flaps is limited. The scrotal flap is an excellent complement to classic flaps, gluteal flaps or hamstrings. It can be used alone or in addition to another musculocutaneous flap, in first or second intention. The scrotal flap is a musculocutaneous flap, using the Dartos, the platys muscle of the scrotum. It is richly vascularized, extensible and resistant. Its great plasticity makes it adaptable to any form of loss of substance, with an arc of rotation that can reach the anal margin. It can also be desepidermized and buried to fill a deep defect. Ten cases of scrotal flaps and their different indications are reviewed: some are used in first intention, others in addition to musculocutaneous flaps. The removal of a scrotal flap is fast and extremely easy. The simple closure of the donor site allows the sampling of half of the scrotum due to the great local laxity. The scrotal flaps achieved quickly healed, as well as the donor sites. Only one recurrence was observed after an inappropriate treatment of underlying osteitis. No complications have occurred. The scrotal musculocutaneous flap, reliable, resistant, quick and easy to remove is an excellent means of coverage of the perineal region. It can be used for the treatment of any loss of perineal substance in humans, but remains particularly useful for the treatment of ischial or perineal pressure sores. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  15. Sudden shrinkage of free rectus abdominis musculocutaneous flap 15 years after maxilla reconstruction

    Directory of Open Access Journals (Sweden)

    Yasushi Mochizuki

    2018-03-01

    Full Text Available A 60-year-old male displayed sudden shrinkage of a left free rectus abdominis musculocutaneous flap, which had been grafted to his left maxilla 15 years previously. No post-reconstructive irradiation had been performed, and no late occlusion of the vascular anastomosis, local infection, recurrence of the maxillary cancer, or body weight loss was observed. However, the shrinkage amounted to approximately 50%. This is considerably more than previously reported cases of shrinkage of various free flaps, which ranged between 10% and 25%. The resultant depression was successfully augmented with a right free deep inferior epigastric artery perforator flap. The residual fat volume of the previously grafted shrunken flap was revealed to be compatible with that of the newly harvested contralateral perforator flap. Thus, the volume of the previously grafted flap may reflect the status of the intact contralateral donor site, although the mechanism of sudden flap shrinkage is unclear.

  16. A histopathological study of bulbar conjunctival flaps occurring in 2 contact lens wearers.

    Science.gov (United States)

    Markoulli, Maria; Francis, Ian C; Yong, Jim; Jalbert, Isabelle; Carnt, Nicole; Cole, Nerida; Papas, Eric

    2011-09-01

    To study the histopathology of paralimbal bulbar conjunctival flaps occurring secondary to soft contact lens wear. Slit-lamp biomicroscopy using sodium fluorescein, cobalt blue light, and a Wratten filter was used to observe the presence, location, and dimensions of bulbar conjunctival flaps presenting in a cohort of contact lens wearers. Two subjects who exhibited such flaps agreed to undergo conjunctival biopsy. Tissue samples, obtained from the region of the flap, and an adjacent unaffected area were processed by standard histopathological methods. In the first subject, analysis of the flap tissue showed even collagen distribution and overall normal histology. The flap of the second subject displayed a mild focal increase in collagen and mild degeneration of collagen, but no increase in elastic tissue. Conjunctival epithelium was normal in both cases. In these 2 subjects, conjunctival flap tissue either was normal or showed only minimal abnormality. There is insufficient evidence for significant pathological change on the time scale of this study.

  17. Versatility of radial forearm free flap for intraoral reconstruction

    Directory of Open Access Journals (Sweden)

    Jeremić Jelena V.

    2015-01-01

    Full Text Available Introduction. The radial forearm free flap has an important role in reconstruction of the oncologic defects in the region of head and neck. Objective. The aim was to present and evaluate clinical experience and results in the radial forearm free transfer for intraoral reconstructions after resections due to malignancies. Methods. This article illustrates the versatility and reliability of forearm single donor site in 21 patients with a variety of intraoral oncologic defects who underwent immediate (19 patients, 90.5% or delayed (2 patients, 9.5% reconstruction using free flaps from the radial forearm. Fascio-cutaneous flaps were used in patients with floor of the mouth (6 cases, buccal mucosa (5 cases, lip (1 case and a retromolar triangle (2 cases defects, or after hemiglossectomy (7 cases. In addition, the palmaris longus tendon was included with the flap in 2 patients that required oral sphincter reconstruction. Results. An overall success rate was 90.5%. Flap failures were detected in two (9.5% patients, in one patient due to late ischemic necrosis, which appeared one week after the surgery, and in another patient due to venous congestion, which could not be salvaged after immediate re-exploration. Two patients required re-exploration due to vein thrombosis. The donor site healed uneventfully in all patients, except one, who had partial loss of skin graft. Conclusion. The radial forearm free flap is, due to multiple advantages, an acceptable method for reconstructions after resection of intraoral malignancies. [Projekat Ministarstva nauke Republike Srbije, br. 41006

  18. Use of various free flaps in progressive hemifacial atrophy.

    Science.gov (United States)

    Baek, Rongmin; Heo, Chanyeong; Kim, Baek-kyu

    2011-11-01

    Romberg disease is an uncommon condition manifested by progressive hemifacial atrophy of the skin, soft tissue, and bone. Facial asymmetry with soft tissue deficiency in Romberg disease causes a significant disability affecting the social life and can bring about many psychological problems. The aim of surgical treatment is cosmetic amelioration of the defect. Several conventional reconstructive procedures have been used for correcting facial asymmetry. They include fat injections, dermal fat grafts, filler injections, cartilage and bone grafts, and pedicled and free flaps. We report our experiences with 11 patients involving 11 free flaps with a minimum 1-year follow-up. All patients were classified as having moderate to severe atrophy. The average age at disease onset was 4.5 years; the average duration of atrophy was 5.2 years. No patients were operated on with a quiescent interval of less than 1 year. The average age at operation was 20.1 years, ranging from 10 to 55 years. Reconstruction was performed using 4 groin dermofat free flaps, 4 latissimus dorsi muscle free flaps, and 3 other perforator flaps. To achieve the finest symmetrical and aesthetic results, several ancillary procedures were performed in 4 patients. These procedures included Le Fort I leveling osteotomy, sagittal split ramus osteotomy, reduction malarplasty and angle plasty, rib and calvarial bone graft, correction of alopecia, and additional fat graft. All patients were satisfied with the results. We believe that a free flap transfer is the requisite treatment modality for severe degree of facial asymmetry in Romberg disease.

  19. Extended Islanded Reverse Sural Artery Flap for Staged Reconstruction of Foot Defects Proximal to Toes

    International Nuclear Information System (INIS)

    Yousaf, M.A.; Abidin, Z.U.; Khalid, K.; Haq, A.U.; Tarar, F.A.; Asif, M.U.; Tarar, M.N.

    2018-01-01

    To assess the outcome of extended delayed reverse sural artery flap for reconstruction of foot defects proximal to toes in terms of flap survival, complication and extended area. Study Design:Case series. Place and Duration of Study:Jinnah Burn and Reconstructive Surgery Centre, Lahore, from February 2015 to April 2017. Methodology:Cases who underwent delayed sural artery flap were inducted. Preoperative hand-held doppler was done to confirm the location of perforator. Two suitable perforators were chosen to raise the extended flap by crossing the proximal limit in all cases. The pedicle was kept minimum 3 cm wide and perfusion was assessed. Flap was delayed for one week and vaccum-assisted closure (VAC) dressing was applied over wound. The second surgery was performed after one week. Proximal perforator was clamped and ligated after checking adequate perfusion of flap. Flap was insetted into defect. Results:Thirty-two patients were reconstructed with delayed reverse sural artery flap. The mean age of the patients was 26.5 +12.2 years. Twenty-four (75%) patients were males and 8 (25%) were females. Twenty-two (68.7%) cases were degloving wounds after road traffic accidents (RTA), 6 (18.7%) were diabetic foot wounds, 4 (12.5%) sustained injury after falling from height and 7 (21.8%) patients had fracture of metatarsals. Twenty-eight flaps were transferred after one week delay, and only in 4 cases, flap were transferred after two weeks. All flaps survived completely. Complications of infection noted in 3 (9.3%) flaps, 3 (9.3%) flaps showed tip necrosis, 2 (6.2%) flaps undergone epidermolysis and only 2 (6.2%) showed venous congestion. Conclusion:Delayed islanded reverse sural artery perforator flap is a reliable and versatile option for resurfacing soft tissue defects of lower limb proximal to the toes with lesser complications and extended coverage area. (author)

  20. Extended Islanded Reverse Sural Artery flap for Staged Reconstruction of Foot Defects Proximal to Toes.

    Science.gov (United States)

    Yousaf, Muhammad Amin; Abidin, Zain Ul; Khalid, Kamran; Haq, Ata Ul; Khalid, Farrukh Aslam; Tarar, Faraz Ahmad; Asif, Muhammad Umar; Tarar, Moazzam Nazeer

    2018-02-01

    Obective:To assess the outcome of extended delayed reverse sural artery flap for reconstruction of foot defects proximal to toes in terms of flap survival, complication and extended area. Case series. Jinnah Burn and Reconstructive Surgery Centre, Lahore, from February 2015 to April 2017. Cases who underwent delayed sural artery flap were inducted. Preoperative hand-held doppler was done to confirm the location of perforator. Two suitable perforators were chosen to raise the extended flap by crossing the proximal limit in all cases. The pedicle was kept minimum 3 cm wide and perfusion was assessed. Flap was delayed for one week and vaccum-assisted closure (VAC) dressing was applied over wound. The second surgery was performed after one week. Proximal perforator was clamped and ligated after checking adequate perfusion of flap. Flap was insetted into defect. Thirty-two patients were reconstructed with delayed reverse sural artery flap. The mean age of the patients was 26.5 12.2 years. Twenty-four (75%) patients were males and 8 (25%) were females. Twenty-two (68.7%) cases were degloving wounds after road traffic accidents (RTA), 6 (18.7%) were diabetic foot wounds, 4 (12.5%) sustained injury after falling from height and 7 (21.8%) patients had fracture of metatarsals. Twenty-eight flaps were transferred after one week delay, and only in 4 cases, flap were transferred after two weeks. All flaps survived completely. Complications of infection noted in 3 (9.3%) flaps, 3 (9.3%) flaps showed tip necrosis, 2 (6.2%) flaps undergone epidermolysis and only 2 (6.2%) showed venous congestion. Delayed islanded reverse sural artery perforator flap is a reliable and versatile option for resurfacing soft tissue defects of lower limb proximal to the toes with lesser complications and extended coverage area.

  1. Value of the post-operative CT in predicting delayed flap failures following head and neck cancer surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bitna; Yoon, Dae Young; Seo, Young Lan; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo; Chung, Chul Hoon [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p < 0.05), intra- or peri-flap air collection > 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery.

  2. Value of the post-operative CT in predicting delayed flap failures following head and neck cancer surgery

    International Nuclear Information System (INIS)

    Kim, Bitna; Yoon, Dae Young; Seo, Young Lan; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo; Chung, Chul Hoon

    2017-01-01

    To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery

  3. Vertical Profunda Artery Perforator Flap for Plantar Foot Wound Closure: A New Application.

    Science.gov (United States)

    Alfonso, Allyson R; Mayo, James L; Sharma, Vishal K; Allen, Robert J; Chiu, Ernest S

    2018-02-01

    Plantar foot reconstruction requires special consideration of both form and function. There are several fasciocutaneous flap options, each with indications and reservations. This case presents a new application of the vertical profunda artery perforator flap for definitive closure of a neuropathic foot ulcer in a young woman with spina bifida. The postoperative course was uneventful, and the flap survived completely. The surgical and donor sites were without wound recurrence at 5-month follow-up. Understanding the variability of foot flap options is important because of unique cases such as the one presented where the wound was caused by specific and less commonly observed foot anatomy. The specific choice to use the vertical profunda artery perforator flap for this patient and her neuropathic wound type was made based on its excellent flexibility, durability, and donor site appeal. The vertical profunda artery perforator flap has adequate surface area and bulk and a favorable pedicle length and caliber, can be thinned, and leaves a donor scar in a less conspicuous area than other popular free flaps for lower-extremity reconstruction. For these reasons, it should be considered a first-line therapy for free flap coverage of selected foot wounds.

  4. Free Flap Reconstruction Monitoring Techniques and Frequency in the Era of Restricted Resident Work Hours.

    Science.gov (United States)

    Patel, Urjeet A; Hernandez, David; Shnayder, Yelizaveta; Wax, Mark K; Hanasono, Matthew M; Hornig, Joshua; Ghanem, Tamer A; Old, Matthew; Jackson, Ryan S; Ledgerwood, Levi G; Pipkorn, Patrik; Lin, Lawrence; Ong, Adrian; Greene, Joshua B; Bekeny, James; Yiu, Yin; Noureldine, Salem; Li, David X; Fontanarosa, Joel; Greenbaum, Evan; Richmon, Jeremy D

    2017-08-01

    Free flap reconstruction of the head and neck is routinely performed with success rates around 94% to 99% at most institutions. Despite experience and meticulous technique, there is a small but recognized risk of partial or total flap loss in the postoperative setting. Historically, most microvascular surgeons involve resident house staff in flap monitoring protocols, and programs relied heavily on in-house resident physicians to assure timely intervention for compromised flaps. In 2003, the Accreditation Council for Graduate Medical Education mandated the reduction in the hours a resident could work within a given week. At many institutions this new era of restricted resident duty hours reshaped the protocols used for flap monitoring to adapt to a system with reduced resident labor. To characterize various techniques and frequencies of free flap monitoring by nurses and resident physicians; and to determine if adapted resident monitoring frequency is associated with flap compromise and outcome. This multi-institutional retrospective review included patients undergoing free flap reconstruction to the head and/or neck between January 2005 and January 2015. Consecutive patients were included from different academic institutions or tertiary referral centers to reflect evolving practices. Technique, frequency, and personnel for flap monitoring; flap complications; and flap success. Overall, 1085 patients (343 women [32%] and 742 men [78%]) from 9 institutions were included. Most patients were placed in the intensive care unit postoperatively (n = 790 [73%]), while the remaining were placed in intermediate care (n = 201 [19%]) or in the surgical ward (n = 94 [7%]). Nurses monitored flaps every hour (q1h) for all patients. Frequency of resident monitoring varied, with 635 patients monitored every 4 hours (q4h), 146 monitored every 8 hours (q8h), and 304 monitored every 12 hours (q12h). Monitoring techniques included physical examination (n = 949 [87

  5. Reconstruction of the anterior floor of the mouth with the inferiorly based nasolabial flap

    NARCIS (Netherlands)

    van Wijk, MP; Damen, A; Nauta, JM; Lichtendahl, DHE; Dhar, BK

    The results of reconstruction of the anterior floor of the mouth, using 105 nasolabial flaps in 79 patients were reviewed in a retrospective study. Of those flaps, 82% healed uneventfully; flap survival was 95%. Considerable flap loss occurred in 5%. Primary dehiscence was observed in 5% of all

  6. The transverse musculo-cutaneous gracilis flap for breast reconstruction: How to avoid complications.

    Science.gov (United States)

    Bodin, Frédéric; Dissaux, Caroline; Dupret-Bories, Agnes; Schohn, Thomas; Fiquet, Caroline; Bruant-Rodier, Catherine

    2016-01-01

    The transverse musculocutaneous gracilis (TMG) flap has become a common solution for breast reconstruction. However, the safe skin paddle limits are not yet understood. In this study, we attempted to address this issue based on our experiences with inferior and posterior skin paddle extension. Forty-four breast reconstructions with TMG flaps performed between November 2010 and January 2014 were analyzed retrospectively. For the first 20 cases, the flap skin paddle was extended 3 cm posteriorly to the middle thigh (group 1). For the next 20 flaps (group 2), the posterior tip was limited to this line, whereas more fat was recruited inferiorly. In the four cases of group 3, the skin flap was extended posteriorly with a second vascular pedicle from the profunda artery perforator (PAP) flap. The weights and the dimensions of the flaps, operating durations, and postoperative complications of the entire series were analyzed. Groups 1 and 2 were statistically compared. Flap complications were statistically more frequent in group 1 compared with group 2 (45 vs. 0%, P = 0.0012); 40% posterior flap tip necrosis was observed in group 1. Conversely, donor site complications were statistically more frequent in group 2 than in group 1 (40 vs. 5%, P = 0.019) with 35% inner thigh dehiscence. In the TMG with extended PAP flap group, the operating duration was 77 min longer compared with the rest of the series with no donor site complications. In one case, limited necrosis occurred at the anterior skin tip. Harvesting the posterior portion of the TMG up to the middle of the posterior thigh may lead to partial flap necrosis. Extending subcutaneous fat removal under the inferior skin incision may increase the risk of donor site complications. Adding a second vascular pedicle from the PAP flap may improve posterior TMG tip perfusion at the expense of a longer operation. © 2015 Wiley Periodicals, Inc.

  7. Generating an Engineered Adipose Tissue Flap Using an External Suspension Device.

    Science.gov (United States)

    Wan, Jinlin; Dong, Ziqing; Lei, Chen; Lu, Feng

    2016-07-01

    The tissue-engineering chamber technique can generate large volumes of adipose tissue, which provides a potential solution for the complex reconstruction of large soft-tissue defects. However, major drawbacks of this technique are the foreign-body reaction and the volume limitation imposed by the chamber. In this study, the authors developed a novel tissue-engineering method using a specially designed external suspension device that generates an optimized volume of adipose flap and avoids the implantation of foreign material. The rabbits were processed using two different tissue-engineering methods, the external suspension device technique and the traditional tissue-engineering chamber technique. The adipose flaps generated by the external suspension device had a normal adipose tissue structure that was as good as that generated by the traditional tissue-engineering chamber, but the flap volume was much larger. The final volume of the engineered adipose flap grew between weeks 0 and 36 from 5.1 ml to 30.7 ml in the traditional tissue-engineering chamber group and to 80.5 ml in the external suspension device group. During the generation process, there were no marked differences between the two methods in terms of structural and cellular changes of the flap, except that the flaps in the traditional tissue-engineering chamber group had a thicker capsule at the early stage. In addition, the enlarged flaps generated by the external suspension device could be reshaped into specific shapes by the implant chamber. This minimally invasive external suspension device technique can generate large-volume adipose flaps. Combined with a reshaping method, this technique should facilitate clinical application of adipose tissue engineering.

  8. A TRAM flap design refinement for use in delayed breast reconstruction.

    LENUS (Irish Health Repository)

    Patel, A J K

    2009-09-01

    Autologous breast reconstruction following mastectomy is commonly achieved using the free Transverse Rectus Abdominis Myocutaneous (TRAM) flap. Since its first description, refinements and modifications have resulted in improved operative techniques and more aesthetically pleasing reconstructions. Pre-operative flap design, however, is a relatively new concept that has not received much attention in the literature. Patients who undergo breast reconstruction may have large, ptotic contralateral breasts. In these patients there is a tendency to raise a large abdominal flap in an attempt to achieve symmetry, or simply a larger breast. This has the potential to lead to tight closure of the abdomen and the risk of subsequent wound problems. Reconstructions that are too small or have inadequate ptosis commit the patient to contralateral breast surgery to achieve symmetry. Pre-operatively designing the flap, using a template created from the opposite breast, can help achieve a good match, often reducing the need for contralateral breast surgery. Even when contralateral breast reduction surgery is planned in advance, many of these patients still require, and prefer, a large reconstruction in order to achieve a well-proportioned result. We present a design template that addresses these particular issues and in the senior author\\'s hands has proved to be a very effective technique. Our technique allows raising an abdominal flap of less vertical height than traditionally used (thus reducing the risk of tight abdominal closure) and incorporates an inverted V-shaped flap of skin from the inferior mastectomy skin flap into the reconstruction. This allows more flap tissue to be available to fill the upper poles of the reconstructed breast and at the same time produces good ptosis.

  9. Possibility of management of lower leg war burns with free flaps

    Directory of Open Access Journals (Sweden)

    Panajotović Ljubomir

    2003-01-01

    Full Text Available Free flaps are used in the surgical treatment of burns for wound closure where the burn is too deep, and in case, when after necrotic tissue excision, the bones, tendons, nerves, and blood vessels remain bare. Covering of the exposed structures is commonly performed in the primary delayed, or in the secondary wound treatment. The possibilities of covering the defects of the lower leg with local flaps are limited. Free flaps are used when all the possibilities of the other reconstructive procedures have been exhausted. The defect of the soft tissue of the lower leg was covered with free flaps in the injured soldiers with deep burns, treated at the Clinic for Plastic Surgery and Burns, Military Medical Academy, Belgrade. In one patient the wound closing was performed immediately after excision of necrotic tissues, and in the other two in the secondary management. The application of free microvascular flaps enabled the closure of large post excision defects of the lower leg in one operation. Our experience in the treatment of these soldiers point to the possibility of coverage of the exposed deep structures with free flaps as early as possible.

  10. Treatment of ischial pressure sores using a modified gracilis myofasciocutaneous flap.

    Science.gov (United States)

    Lin, Haodong; Hou, Chunlin; Chen, Aimin; Xu, Zhen

    2010-04-01

    Despite the availability of a variety of flap reconstruction options, ischial pressure sores continue to be the most difficult pressure sores to treat. This article describes a successful surgical procedure for the coverage of ischial ulcers using a modified gracilis myofasciocutaneous flap. From August 2000 to April 2004, 12 patients with ischial sores were enrolled in the study. All patients underwent early aggressive surgical debridement followed by surgical reconstruction with a modified gracilis myofasciocutaneous flap. The follow-up period ranged from 13 to 86 months, with a mean of 44 months. Overall, 91.7% of the flaps (11 of 12) survived primarily. Partial flap necrosis occurred in one patient. Primary wound healing occurred without complications at both the donor and recipient sites in all cases. In one patient, grade II ischial pressure sores recurred 13 months after the operation. There was no recurrence in other 11 patients. A modified gracilis myofasciocutaneous flap provides a good cover for ischial pressure sores. Because it is easy to use and has favorable results, it can be used in the primary treatment for large and deep ischial pressure sores. Copyright Thieme Medical Publishers.

  11. The vascularized groin lymph node flap (VGLN): Anatomical study and flap planning using multi-detector CT scanner. The golden triangle for flap harvesting.

    Science.gov (United States)

    Zeltzer, Assaf A; Anzarut, Alexander; Braeckmans, Delphine; Seidenstuecker, Katrin; Hendrickx, Benoit; Van Hedent, Eddy; Hamdi, Moustapha

    2017-09-01

    A growing number of surgeons perform lymph node transfers for the treatment of lymphedema. When harvesting a vascularized lymph node groin flap (VGLNF) one of the major concerns is the potential risk of iatrogenic lymphedema of the donor-site. This article helps understanding of the lymph node distribution of the groin in order to minimize this risk. Fifty consecutive patients undergoing abdominal mapping by multi-detector CT scanner were included and 100 groins analyzed. The groin was divided in three zones (of which zone II is the safe zone) and lymph nodes were counted and mapped with their distances to anatomic landmarks. Further node units were plotted and counted. The average age was 48 years. A mean number of nodes of 6.5/groin was found. In zone II, which is our zone of interest a mean of 3.1 nodes were counted with a mean size of 7.8 mm. In three patients no nodes were found in zone II. In five patients nodes were seen in zone II but were not sufficient in size or number to be considered a lymph node unit. On average the lymph node unit in zone II was found to be 48.3 mm from the pubic tubercle when projected on a line from the pubic tubercle to the anterior superior iliac spine, 16.0 mm caudal to this line, and 20.4 mm above the groin crease. On average the lymph node unit was a mean of 41.7 mm lateral to the SCIV-SIEV confluence. This study provides increased understanding of the lymphatic anatomy in zone II of the groin flap and suggests a refined technique for designing the VGLNF. As with any flap there is a degree of individual patient variability. However, having information on the most common anatomy and flap design is of great value. © 2017 Wiley Periodicals, Inc.

  12. Improving esthetic results in benign parotid surgery: statistical evaluation of facelift approach, sternocleidomastoid flap, and superficial musculoaponeurotic system flap application.

    Science.gov (United States)

    Bianchi, Bernardo; Ferri, Andrea; Ferrari, Silvano; Copelli, Chiara; Sesenna, Enrico

    2011-04-01

    The purpose of this article was to analyze the efficacy of facelift incision, sternocleidomastoid muscle flap, and superficial musculoaponeurotic system flap for improving the esthetic results in patients undergoing partial parotidectomy for benign parotid tumor resection. The usefulness of partial parotidectomy is discussed, and a statistical evaluation of the esthetic results was performed. From January 1, 1996, to January 1, 2007, 274 patients treated for benign parotid tumors were studied. Of these, 172 underwent partial parotidectomy. The 172 patients were divided into 4 groups: partial parotidectomy with classic or modified Blair incision without reconstruction (group 1), partial parotidectomy with facelift incision and without reconstruction (group 2), partial parotidectomy with facelift incision associated with sternocleidomastoid muscle flap (group 3), and partial parotidectomy with facelift incision associated with superficial musculoaponeurotic system flap (group 4). Patients were considered, after a follow-up of at least 18 months, for functional and esthetic evaluation. The functional outcome was assessed considering the facial nerve function, Frey syndrome, and recurrence. The esthetic evaluation was performed by inviting the patients and a blind panel of 1 surgeon and 2 secretaries of the department to give a score of 1 to 10 to assess the final cosmetic outcome. The statistical analysis was finally performed using the Mann-Whitney U test for nonparametric data to compare the different group results. P less than .05 was considered significant. No recurrence developed in any of the 4 groups or in any of the 274 patients during the follow-up period. The statistical analysis, comparing group 1 and the other groups, revealed a highly significant statistical difference (P esthetic results in benign parotid surgery. The evaluation of functional complications and the recurrence rate in this series of patients has confirmed that this technique can be safely

  13. RECONSTRUCTION OF FACIAL SKIN DEFECT BY VARIOUS FLAPS : OUR EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Atishkumar B.

    2015-08-01

    Full Text Available INTRODUCTION : Face represents complete personality of human being. Cosmetically it is very important part of a person especially for woman. There are many situations when due to disease or trauma, facial defect arises, which requires reconstruction by either local or distant surgical flaps . METHODS AND MATERIALS : In rural places, we come across many patients suffering from trauma and skin malignancy of face. These patients require reconstruction done esthetically with local flaps. Objective of this study is to share our exper ience of providing esthetically good results at our secondary referral care center. Hereby, we present case series of 14 patients operated at our institute. These patients were analyzed according to the age, sex, nature of injury and anatomical location of lesion on the face. All these patients were operated and reconstruction of defect was done with various local flaps best suited for respective lesion, under local anesthesia or sedation. Post - operative nature of wound was analyzed for flap viability or fl ap necrosis . RESULTS : Amongst them were 7 male and 7 female, ages ranging from 4 to 80 years. 7out of 14 patients were of basal cell carcinoma, 4 were due to trauma, 2 were due to dog bite and 1 case of recurrent pleomorphic adenoma at root of nose. All patients had excellent flap viability at end of 6 months and flap achieving almost similar color and contour as that of surrounding skin. CONCLUSION : Reconstruction of facial defects by local flaps is very easy and cost effective technique. This can be don e even at secondary referral care centre with minimal availability of facilities

  14. Role of the Use of Omental Flap in Prognosis of Cases with Induced Acute Pancreatitis in Experimental Dogs

    OpenAIRE

    Mohamed Hassan; Nader Shaaban; Ashraf M Abu-Seida; Mostafa Khodeir; Reem Jan; Hisham Elsharkawy; Engie Hefnawy

    2016-01-01

    Aim Acute pancreatitis frequently involves peripancreatic tissues and remote organ systems resulting in severe complications and high risk of mortality. Therefore, the present study was carried out to assess the effect of omental flap as a new treatment of acute pancreatitis. Methods Ten mongrel dogs with experimentally induced acute pancreatitis were randomly divided into two equal groups; treated and control groups. The pancreas was wrapped with omental flap in the treated group and the pan...

  15. Combined Endoscopic Transorbital and Endonasal Repair of High Flow Orbital Apex/Middle Fossa Cerebrospinal Fluid Leak with a Nasoseptal Flap.

    Science.gov (United States)

    Lucke-Wold, Brandon; Mendez, Gustavo; Cua, David; Akins, Paul; Gillham, Haley; Ciporen, Jeremy

    2018-01-01

    High flow orbital apex or middle fossa cerebrospinal fluid (CSF) leaks can be life threatening and complex to repair. These leaks associated with large dural defects are most commonly repaired with an open temporalis muscle patch or free flaps, but these flaps do not always stop the leak. A 65-year-old patient presented two years after orbital exenteration and radiation for squamous cell carcinoma. He developed multi-organism meningitis and pneumocephalus secondary to a large high-flow orbital apex/middle fossa CSF leak. To repair the leak, a combined endoscopic transorbital/endonasal approach with pedicled nasospetal flap and dermis fat graft was used. We describe the unique endoscopic technique that was used to treat the life threatening high flow orbital apex/middle fossa CSF leak. The technique allowed the use of the transposed pedicled flap, which is an alternative to the free flap in controlling CSF leak. Cisternogram post-operatively and clinical exam confirmed resolution of CSF leak. Although a critically ill patient at admission with a modified Rankin scale (MRS) of 5, he was discharged home on continued IV antibiotic therapy with a MRS of 3. Endoscopic evaluation at three months after treatment showed the effectiveness of the flap and he continued to improve clinically. This is the first case to describe a combined endoscopic transorbital and endonasal repair of high flow orbital apex/middle fossa CSF leak with a pedicled nasoseptal flap. These techniques can be utilized during initial reconstruction after orbital exenteration or as a salvage flap.

  16. Double papilla flap technique for dual purpose

    Directory of Open Access Journals (Sweden)

    P Mohan Kumar

    2012-01-01

    Full Text Available Marginal tissue recession exposes the anatomic root on the teeth, which gives rise to -common patient complaints. It is associated with sensitivity, tissue irritation, cervical abrasions, and esthetic concerns. Various types of soft tissue grafts may be performed when recession is deep and marginal tissue health cannot be maintained. Double papilla flap is an alternative technique to cover isolated recessions and correct gingival defects in areas of insufficient attached gingiva, not suitable for a lateral sliding flap. This technique offers the advantages of dual blood supply and denudation of interdental bone only, which is less susceptible to permanent damage after surgical exposure. It also offers the advantage of quicker healing in the donor site and reduces the risk of facial bone height loss. This case report presents the advantages of double papilla flap in enhancing esthetic and functional outcome of the patient.

  17. Lower abdominal wall reconstructions with pedicled rectus femoris flaps

    International Nuclear Information System (INIS)

    Arashiro, Ken; Nishizeki, Osamu; Ishida, Kunihiro

    2003-01-01

    During the past 10 years, seven pedicled rectus femoris muscle or musculocutaneous flaps were used to repair lower abdominal defects; three recalcitrant incisional hernias with previous radiotherapy, two long-standing wound infections after synthetic mesh reconstruction, one posttraumatic wall defect and one metastatic tumor. There were two flap complications, one skin paddle necrosis and one wound infection. There was no significant disability of the donor limb encountered. During the two-year and seven month average follow-up, there was no recurrence of the problems except for one minor fascial dehiscence in the patient with metastatic abdominal wall tumor. Easy approach, rapid harvest, relatively large and reliable overlying fascia lata, a single dominant neurovascular pedicle, easy primary closure of the donor site, and minimal donor site morbidity all make the rectus femoris flap a good alternative flap for lower abdominal wall reconstruction. It is especially useful in a condition where synthetic mesh would be unsuitable for defects with infection or recurrent incisional hernia after radiotherapy. (author)

  18. Estudo da isquemia e reperfusão em retalhos cutâneos de ratos The study of the ischemia and reperfusion in skin flaps of rats

    Directory of Open Access Journals (Sweden)

    Frederico Alonso Sabino de Freitas

    2002-01-01

    Full Text Available INTRODUÇÃO: Múltiplos fatores têm sido implicados na patogênese da lesão de isquemia/reperfusão da pele, incluindo as espécies reativas de oxigênio. OBJETIVO: Estudar a lesão de isquemia/reperfusão em retalhos cutâneos de ratos avaliando os níveis teciduais do malonildialdeído (MDA e xantina oxidase (XO. MÉTODOS: Foram utilizados 8 ratos Wistar, com peso entre 300 - 400g, sendo confeccionados 2 retalhos epigástricos por animal (controle e experimento, um deles submetido à 16h de isquemia (RI seguida de 45 min de reperfusão (RR e o outro controle (RC. Foram colhidas 3 biópsias de pele dos retalhos (RC, RI, RR e encaminhadas para dosagem de MDA e XO. RESULTADOS: A análise bioquímica mostrou aumento significativo dos níveis teciduais de MDA e XO após a reperfusão em relação aos retalhos controles. CONCLUSÃO: Retalhos epigástricos de ratos submetidos à 16h de isquemia e 45min de reperfusão apresentam elevação dos níveis teciduais de MDA e XO, caracterizando a lipoperoxidação da membrana celular.INTRODUCTION: Multiple factors have been implicated in the pathogenesis of reperfusion injury in the skin, including the reactive oxygen species. OBJECTIVE: The aim was to evaluate the effect of reperfusion injury in the rat skin flap evaluated by tissue assay for malonyldialdehyde (MDA and xanthine oxidase (XO. METHODS: 8 Wistar rats were used, between 300-400g weight and two identical epigastric flaps were raised in each animal (control and experiment, the vasculature of one flap was left intact and in the second flap the arterial pedicle was clamped for 16 hours and reperfused for 45 minutes. Skin samples were obtained from each flap after these periods of time and submitted to MDA and XO analysis. RESULTS: Reperfused flaps had significantly increased MDA and XO values compared to the control flaps biopsies. CONCLUSION: The lipid peroxidation levels were higher in the rat epigastric skin flaps subjected to 16 hours of

  19. Morphological effect of a scallop shell on a flapping-type tidal stream generator

    International Nuclear Information System (INIS)

    Le, Tuyen Quang; Ko, Jin Hwan; Byun, Doyoung

    2013-01-01

    Inspired by nature, flapping-type tidal stream generators have been introduced in recent years. The improvement in their power generation ability is known to be a critical factor in the success of these generators. So far, corrugation and camber observed in flying insects and swimming animals are known to enhance the performance of a flapping-type propulsive system. In this study, we explore the effect of corrugation and camber in a system that mimics a scallop shell in terms of its ability to extract flow energy through a two-dimensional Navier–Stokes simulation. The simulations show that the size and the activity of the leading edge vortex are strongly affected by the morphological factors of the mimicked foils, the effects of which are then advantageous in terms of the power efficiency of the flapping-type tidal stream generator. Eventually, an optimal mimicked foil, as suggested based on the morphological effects, would be a good alternative type of foil with a typical section with regard to the hydrodynamic performance and structural properties of tidal stream generators. (paper)

  20. Human FAN1 promotes strand incision in 5'-flapped DNA complexed with RPA.

    Science.gov (United States)

    Takahashi, Daisuke; Sato, Koichi; Hirayama, Emiko; Takata, Minoru; Kurumizaka, Hitoshi

    2015-09-01

    Fanconi anaemia (FA) is a human infantile recessive disorder. Seventeen FA causal proteins cooperatively function in the DNA interstrand crosslink (ICL) repair pathway. Dual DNA strand incisions around the crosslink are critical steps in ICL repair. FA-associated nuclease 1 (FAN1) is a DNA structure-specific endonuclease that is considered to be involved in DNA incision at the stalled replication fork. Replication protein A (RPA) rapidly assembles on the single-stranded DNA region of the stalled fork. However, the effect of RPA on the FAN1-mediated DNA incision has not been determined. In this study, we purified human FAN1, as a bacterially expressed recombinant protein. FAN1 exhibited robust endonuclease activity with 5'-flapped DNA, which is formed at the stalled replication fork. We found that FAN1 efficiently promoted DNA incision at the proper site of RPA-coated 5'-flapped DNA. Therefore, FAN1 possesses the ability to promote the ICL repair of 5'-flapped DNA covered by RPA. © The Authors 2015. Published by Oxford University Press on behalf of the Japanese Biochemical Society. All rights reserved.

  1. Does Fibrin Sealant Reduce Seroma after Immediate Breast Reconstruction Utilizing a Latissimus Dorsi Myocutaneous Flap?

    Directory of Open Access Journals (Sweden)

    Han Gyu Cha

    2012-09-01

    Full Text Available Background The most common complication of latissimus dorsi myocutaneous flap in breastreconstruction is seroma formation in the back. Many clinical studies have shown that fibrinsealant reduces seroma formation. We investigated any statistically significant differences inpostoperative drainage and seroma formation when utilizing the fibrin sealant on the site ofthe latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction afterskin-sparing partial mastectomy.Methods A total of 46 patients underwent immediate breast reconstruction utilizing alatissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedurewithout fibrin sealant and the other 23 were administered the fibrin sealant. All flaps wereelevated with manual dissection by the same surgeon and were analyzed to evaluate thepotential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U testwere used for analyzing the drainage volume according to age, weight of the breast specimen,and body mass index.Results Although not statistically significant, the cumulative drainage fluid volume was higherin the control group until postoperative day 2 (530.1 mL compared to 502.3 mL, but thefibrin sealant group showed more drainage beginning on postoperative day 3. The donor sitecomparisons showed the fibrin sealant group had more drainage beginning on postoperativeday 3 and the drain was removed 1 day earlier in the control group.Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Becausethe benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussedwith patients before its use as a part of informed consent.

  2. Free toe pulp flap for finger pulp and volar defect reconstruction

    Directory of Open Access Journals (Sweden)

    Jyoshid R Balan

    2016-01-01

    Full Text Available Background: Fingertip injury requiring flap cover is very common in the modern era. The ideal cover should fulfill both functional and aesthetic improvement. Materials and Methods: From June 2015 to April 2016, we performed seven free toe pulp flaps for finger defect reconstruction. All patients were males. Five flaps were done in emergency post-traumatic cases, and two were done in elective set up. The cases included reconstruction of three thumbs, one index and one ring finger in an emergency set up and two ring fingers in the elective. Thumb reconstruction was done with great toe lateral pulp and the other digits reconstructed with second toe pulp flap. Follow-up evaluation included both functional and aesthetic assessment. Results: Five flaps survived completely, one suffered partial loss, and one flap failed completely. The median follow-up period was 9 months. The median duration of surgery was 255 min (range 210 to 300 min. The median two-point discrimination was 6.5 mm (range 4–8 mm. There was the return of temperature sensation in all patients; two had cold intolerance. The Semmes-Weinstein monofilament score varied from 3.61 to 5.07 (median filament index value 4.31/pressure value of 2 g/mm2. Three patients had delayed donor site wound healing. Conclusions: The free toe pulp flap is an efficient choice for fingertip and volar finger defects reconstruction with an excellent tissue match.

  3. Propeller flaps for lower-limb trauma | Rogers | South African ...

    African Journals Online (AJOL)

    The propeller flap has become a versatile and important component in our reconstructive algorithm following complex lower limb trauma. First described by Hyakusoku in 1991, it has since been adapted and modified by Hallock and Teo. This article outlines our experience specifically with perforator pedicled propeller flaps ...

  4. Free vascularized flaps for reconstruction of the mandible: complications, success, and dental rehabilitation.

    Science.gov (United States)

    van Gemert, Johannes T M; van Es, Robert J J; Rosenberg, Antoine J W P; van der Bilt, Andries; Koole, Ron; Van Cann, Ellen M

    2012-07-01

    To evaluate complications and success of mandibular reconstruction with free fibula flaps, iliac crest flaps, and forearm flaps with reconstruction plates and to evaluate dental rehabilitation after these reconstructions. Eighty-three patients with segmental mandibular defects were included. Correlation analyses were used to determine the relationship between reconstruction type and clinical parameters with recipient-site complications and success. The dental rehabilitation was evaluated in successfully reconstructed survivors. Multivariate analyses showed significant correlations between flap type and success (P < .0001). Of the patients, 51 (61%) were alive 2 years after the reconstruction. Mandibular reconstruction with a free forearm flap and reconstruction plate was associated with higher complication rates at the recipient site and higher failure rates compared with reconstruction with free vascularized bone flaps. Of the 32 successfully reconstructed survivors, 14 (44%) had a complete dental rehabilitation, of which 10 had dental implants and 4 did not. Only 6 (29%) of the edentulous survivors ultimately had an implant-supported prosthesis. Reconstruction of the mandible with a free vascularized bone flap is superior to reconstruction with a free forearm flap with a reconstruction plate. Complete dental rehabilitation was reached in fewer than half of the surviving patients. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Wake Measurement Downstream of a Hybrid Wing Body Model with Blown Flaps

    Science.gov (United States)

    Lin, John C.; Jones, Gregory S.; Allan, Brian G.; Westra, Bryan W.; Collins, Scott W.; Zeune, Cale H.

    2010-01-01

    Flow-field measurements were obtained in the wake of a full-span Hybrid Wing Body model with internally blown flaps. The test was performed at the NASA Langley 14 x 22 Foot Subsonic Tunnel at low speeds. Off-body measurements were obtained with a 7-hole probe rake survey system. Three model configurations were investigated. At 0deg angle of attack the surveys were completed with 0deg and 60deg flap deflections. At 10deg angle of attack the wake surveys were completed with a slat and a 60deg flap deflection. The 7-hole probe results further quantified two known swirling regions (downstream of the outboard flap edge and the inboard/outboard flap juncture) for the 60deg flap cases with blowing. Flowfield results and the general trends are very similar for the two blowing cases at nozzle pressure ratios of 1.37 and 1.56. High downwash velocities correlated with the enhanced lift for the 60deg flap cases with blowing. Jet-induced effects are the largest at the most inboard station for all (three) velocity components due in part to the larger inboard slot height. The experimental data are being used to improve computational tools for high-lift wings with integrated powered-lift technologies.

  6. Use of Systemic Rosmarinus Officinalis to Enhance the Survival of Random-Pattern Skin Flaps

    Directory of Open Access Journals (Sweden)

    Bilsev İnce

    2016-12-01

    Full Text Available Background: Skin flaps are commonly used in soft-tissue reconstruction; however, necrosis can be a frequent complication. Several systemic and local agents have been used in attempts to improve skin flap survival, but none that can prevent flap necrosis have been identified. Aims: This study aims to determine whether the use of systemic Rosmarinus officinalis (R. officinalis extract can prevent flap necrosis and improve skin flap recovery. Study Design: Animal experimentation. Methods: Thirty-five Wistar albino rats were divided in five groups. A rectangular random-pattern flaps measuring 8×2 cm was elevated from the back of each rat. Group I was the control group. In Group II, 0.2 ml of R. officinalis oil was given orally 2h before surgery. R. officinalis oil was then applied orally twice a day for a week. In Group III, R. officinalis oil was given orally twice a day for one week before surgery. At the end of the week, 0.2 mL of R. officinalis oil was given orally 2 h before surgery. In Group IV, 0.2 mL of R. officinalis oil was injected subcutaneously 2 h before surgery. After the surgery, 0.2 mL R. officinalis oil was injected subcutaneously twice a day for one week. In Group V, 0.2 mL R. officinalis oil was injected subcutaneously twice a day for one week prior to surgery. At the end of the week, one last 0.2 mL R. officinalis oil injection was administered subcutaneously 2 h before surgery. After the surgery, 0.2 mL R. officinalis oil was injected subcutaneously twice a day for one week. Results: The mean percentage of viable surface area was significantly greater (p<0.05 in Groups II, III, IV, and V as compared to Group I. Mean vessel diameter was significantly greater (p<0.05 in Groups II, III, IV, and V as compared to Group I. Conclusion: We have determined that, in addition to its anti-inflammatory and anti-oxidant effects, R. officinalis has vasodilatory effects that contribute to increased skin flap survival.

  7. Management of a Traumatic Flap Dislocation Seven Years after LASIK

    Directory of Open Access Journals (Sweden)

    Majid Moshirfar

    2011-01-01

    Full Text Available Seven years after uneventful laser in situ keratomileusis (LASIK, a 48-year-old woman presented one week after being hit with an iron cord with blurry vision, pain, and irritation. The injury resulted in traumatic flap dislocation, epithelial ingrowth, and macrostriae. Following epithelial removal, the flap was refloated and repositioned. Nine interrupted sutures were used to secure the flap. Three-weeks after surgery with no sutures remaining, the epithelial ingrowth and macrostriae had resolved with a visual acuity of 20/20.

  8. The use of free musculocutaneous flaps to cover chronic radiation ulcers

    International Nuclear Information System (INIS)

    Tsujiguchi, Kounosuke; Tajima, Sadao; Tanaka, Yoshio; Hira, Michiya; Imai, Keisuke; Fukae, Eiichi; Omiya, Yuka.

    1992-01-01

    Three patients with chronic radiation ulcer treated with free musculocutaneous flap transfer are described. The first patient was a 66-year-old woman who developed sacral ulcer 7 years after radiation combined with surgery for uterine cancer. After debridement of this ulcer, interpositional vein grafts 30 cm in length was used to reconstruct an 'extended' latissimus dorsi musculocutaneous flap. The second patient was a 62-year-old woman. She developed ulcer on her chest 15 years after postoperative irradiation for breast cancer. Radiation damage extended to the myocardium and pulmonary parenchyma. After careful debridement, reconstruction was performed by using the free rectus abdominis musculocutaneous flap. The last patient was a 72-year-old woman. Ulcer of the right axilla developed 19 years after postoperative irradiation for breast cancer. Reconstruction was performed by using a free rectus abdominis musculocutaneous flap. In these patients in whom radiation-damaged tissue was not completely excised, favorable results could be attained by using the transfer of the free musculocutaneous flaps. (N.K.)

  9. Expanded flap to repair facial scar left by radiotherapy of hemangioma.

    Science.gov (United States)

    Zhao, Donghong; Ma, Xinrong; Li, Jiang; Zhang, Lingfeng; Zhu, Baozhen

    2014-09-01

    This study explored the feasibility and clinical efficacy of expanded flap to repair facial scar left by radiotherapy of hemangioma. From March 2000 to April 2011, 13 cases of facial cicatrices left by radiotherapy of hemangioma have been treated with implantation surgery of facial skin dilator under local anesthesia. After water flood expansion for 1-2 months, resection of facial scar was performed, and wound repairing with expansion flap transfer was done. Thirteen patients were followed up from 5 months to 3 years. All patients tolerated flap transfer well; no contracture occurred during the facial expansion flap transfer. The incision scar was not obvious, and its color and texture were identical to surrounding skin. In conclusion, the use of expanded flap transfer to repair the facial scar left by radiotherapy of hemangioma is advantageous due to its simplicity, flexibility, and large area of repairing. This method does not affect the subsequent facial appearance.

  10. Effect of Reynolds Number on Aerodynamics of Airfoil with Gurney Flap

    Directory of Open Access Journals (Sweden)

    Shubham Jain

    2015-01-01

    Full Text Available Steady state, two-dimensional computational investigations performed on NACA 0012 airfoil to analyze the effect of variation in Reynolds number on the aerodynamics of the airfoil without and with a Gurney flap of height of 3% chord are presented in this paper. RANS based one-equation Spalart-Allmaras model is used for the computations. Both lift and drag coefficients increase with Gurney flap compared to those without Gurney flap at all Reynolds numbers at all angles of attack. The zero lift angle of attack seems to become more negative as Reynolds number increases due to effective increase of the airfoil camber. However the stall angle of attack decreased by 2° for the airfoil with Gurney flap. Lift coefficient decreases rapidly and drag coefficient increases rapidly when Reynolds number is decreased below critical range. This occurs due to change in flow pattern near Gurney flap at low Reynolds numbers.

  11. Saphenous vein grafts for perforator flap salvage in autologous breast reconstruction.

    Science.gov (United States)

    Flores, Jaime I; Rad, Ariel N; Shridharani, Sachin M; Stapleton, Sahael M; Rosson, Gedge D

    2009-01-01

    Although the use of saphenous vein grafts in free-flap salvage and extremity replantation is relatively common, their use in breast reconstruction is rare. These two case reports represent extreme alternatives for breast reconstruction flap salvage. In our normal daily practice, the overwhelming majority of elective breast reconstructions proceed smoothly. However, the occasional patient may require saphenous vein graft flap rescue for completion of the reconstruction. (c) 2008 Wiley-Liss, Inc.

  12. Delayed flap coverage of open extremity fractures after previous vacuum-assisted closure (VAC) therapy - worse or worth?

    Science.gov (United States)

    Steiert, Andreas E; Gohritz, Andreas; Schreiber, Thomas C; Krettek, Christian; Vogt, Peter M

    2009-05-01

    Controversy remains regarding timing in the management of complex traumatic lower extremity defects. Many authors recommend a definitive bony and soft tissue reconstruction within a critical period of 72 h, yet in many patients this may be impossible due to concomitant injuries or delayed referral. However, little data are available on the results of delayed flap reconstruction of complex traumatic extremity defects, especially using new technologies of wound coverage such as vacuum-assisted closure (VAC((R))) therapy which may reduce the disadvantages of conventional open wound therapy prior to a subsequent flap reconstruction. We retrospectively analysed the soft tissue reconstructions in 43 open extremity fractures during a 4-year period with special regard to complications, overall flap loss and wound infection. A total of 29 male and 13 female patients with 33 open fractures of the lower and 10 of the upper extremity were included. All patients had been referred from a trauma centre at a mean interval of 19 days (range 1-96 days) after the trauma event with temporary VAC((R)) of their wounds after initial fracture fixation and initial debridement of necrotic tissue. Flap reconstruction was thus only possible later than 72 h and definitive wound closure was achieved at a mean time of 28 days (range 3-106 days). Overall, three pedicled flaps were lost and one of 38 microsurgical free flaps (2.6%) underwent necrosis, the cause of which was unrelated to treatment delay. According to this study, the flap reconstructions performed beyond the frequently quoted critical interval yielded similar results to those of immediate reconstruction within the first 3 days, as reported in the literature. This strategy is in accordance with the principles of 'Damage Control Orthopaedics (DCO)' and may reduce the importance of emergency reconstructions, especially in poly-traumatised patients.

  13. Microsurgical free flap reconstructions of head and neck region in 406 cases: a 13-year experience.

    Science.gov (United States)

    Gerressen, Marcus; Pastaschek, Claudia Inge; Riediger, Dieter; Hilgers, Ralf-Dieter; Hölzle, Frank; Noroozi, Nelson; Ghassemi, Alireza

    2013-03-01

    The reconstruction of extended soft tissue and bony defects in the maxillofacial region with microsurgical flaps is considered to be the therapy of first choice. The aim of this retrospective study was to detect different influencing factors concerning flap survival. We examined the data of 406 patient cases (121 female and 285 male cases; mean age, 57 years) undergoing reconstruction with a microsurgical flap in our facility between 1998 and 2010. In these cases 326 soft tissue flaps (radial forearm flap, scapula flap, latissimus dorsi flap, anterolateral thigh flap, lateral arm flap, and jejunum flap) and 80 bony flaps (fibula flap and deep circumflex iliac artery flap) were examined. Evaluated parameters were, among others, the timing of reconstruction, defect localization, and recipient vessels used (external vs internal jugular system), as well as anticoagulative management. We statistically analyzed data by means of a χ(2) test, taking account of the odds ratio with P < .05, which was deemed significant. The overall flap survival rate was approximately 92%, without any gender- or age-specific differences. Primary reconstructions proceeded distinctly more successfully than secondary reconstructions (P < .01). Likewise, the defect localization exerted a significant effect on the survival rate (P = .01), with a more caudal localization affecting flap survival positively. Finally, neither the anticoagulation regimen nor the choice of recipient vein system exercised an influence on the survival rate. Microsurgical tissue transfer is a convenient and reliable method in maxillofacial surgery, provided that one is aware of the determining factors for success. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Increased Flap Weight and Decreased Perforator Number Predict Fat Necrosis in DIEP Breast Reconstruction

    Directory of Open Access Journals (Sweden)

    Carolyn L. Mulvey, BS

    2013-05-01

    Conclusions: Flaps with increasing weight have increased risk of fat necrosis. These data suggest that inclusion of more than 1 perforator may decrease odds of fat necrosis in large flaps. Perforator flap breast reconstruction can be performed safely; however, considerations concerning race, body mass index, staging with tissue expanders, perforator number, and flap weight may optimize outcomes.

  15. The management of pelvic pressure ulcers by myocutaneous flaps ...

    African Journals Online (AJOL)

    Pressure ulcers or ischaemic necrosis of tissues over bony eminences due to pressure, heal very slowly. Vascularised tissues such as myocutaneous flaps are necessary to cover the ulcer and accelerate healing. This study was done to share our experience with methods of myocutaneous flaps in the treatment of pressure ...

  16. Scrotal Reconstruction with a Pedicled Gracilis Muscle Flap after ...

    African Journals Online (AJOL)

    Several scrotal reconstructive options are available including split thickness skin grafts, scrotal advancement flaps, local fasciocutaneous, muscle or myocutaneous flaps, and free tissue transfer. We report a case of a 34 year old African male who presented as a referral from a district hospital with a scrotal defect and ...

  17. Flap Endonuclease 1 Limits Telomere Fragility on the Leading Strand*

    Science.gov (United States)

    Teasley, Daniel C.; Parajuli, Shankar; Nguyen, Mai; Moore, Hayley R.; Alspach, Elise; Lock, Ying Jie; Honaker, Yuchi; Saharia, Abhishek; Piwnica-Worms, Helen; Stewart, Sheila A.

    2015-01-01

    The existence of redundant replication and repair systems that ensure genome stability underscores the importance of faithful DNA replication. Nowhere is this complexity more evident than in challenging DNA templates, including highly repetitive or transcribed sequences. Here, we demonstrate that flap endonuclease 1 (FEN1), a canonical lagging strand DNA replication protein, is required for normal, complete leading strand replication at telomeres. We find that the loss of FEN1 nuclease activity, but not DNA repair activities, results in leading strand-specific telomere fragility. Furthermore, we show that FEN1 depletion-induced telomere fragility is increased by RNA polymerase II inhibition and is rescued by ectopic RNase H1 expression. These data suggest that FEN1 limits leading strand-specific telomere fragility by processing RNA:DNA hybrid/flap intermediates that arise from co-directional collisions occurring between the replisome and RNA polymerase. Our data reveal the first molecular mechanism for leading strand-specific telomere fragility and the first known role for FEN1 in leading strand DNA replication. Because FEN1 mutations have been identified in human cancers, our findings raise the possibility that unresolved RNA:DNA hybrid structures contribute to the genomic instability associated with cancer. PMID:25922071

  18. RANS Simulations of Aerodynamic Performance of NACA 0015 Flapped Airfoil

    Directory of Open Access Journals (Sweden)

    Sohaib Obeid

    2017-01-01

    Full Text Available An analysis of 2D subsonic flow over an NACA 0015 airfoil with a 30% trailing edge flap at a constant Reynolds number of 106 for various incidence angles and a range of flap deflections is presented. The steady-state governing equations of continuity and momentum conservation are solved combined with the realizable k-ε turbulence model using the ANSYS-Fluent code (Version 13.7, ANSYS, Inc., Canonsburg, PA, USA. The primary objective of the study is to provide a comprehensive understanding of flow characteristics around the NACA 0015 airfoil as a function of the angle of attack and flap deflection at Re = 106 using the realizable k-ε turbulence model. The results are validated through comparison of the predictions with the free field experimental measurements. Consistent with the experimental observations, the numerical results show that increased flap deflections increase the maximum lift coefficient, move the zero-lift angle of attack (AoA to a more negative value, decrease the stall AoA, while the slope of the lift curve remains unchanged and the curve just shifts upwards. In addition, the numerical simulations provide limits for lift increment Δ C l and Cl, max values to be 1.1 and 2.2, respectively, obtained at a flap deflection of 50°. This investigation demonstrates that the realizable k-ε turbulence model is capable of predicting flow features over an airfoil with and without flap deflections with reasonable accuracy.

  19. Anatomical Basis and Clinical Application of Synovial Flaps in the Wrist and Distal Forearm.

    Science.gov (United States)

    Colen, David L; Yeh, Jiun-Ting; Colen, Lawrence B

    2017-05-01

    Neuropathic symptoms after median nerve repair at the wrist or secondary to refractory carpal tunnel syndrome may become debilitating. These symptoms develop because of perineural adhesions, intraneural fibrosis, and fixation of the nerve to the transverse carpal ligament after surgery, and often require neurolysis. Interposition of vascularized soft tissue over the median nerve at the time of neurolysis prevents recurrence of such adhesions. The synovial flap, fashioned from the synovial lining of the flexor tendon sheath, is an ideal tissue for this purpose. Previous authors have described the surgical technique of the synovial flap, but the anatomical basis and design of the flap have not been previously discussed. Twenty fresh cadaver upper extremities were injected with Microfil to analyze the arterial anatomy, flap dimensions, and arc of rotation of the flexor tendon synovium mobilized as a flap suitable for coverage of the median nerve at the wrist. The authors determined that both radial and ulnar-based flaps are clinically useful for providing coverage in the wrist and distal forearm. This flap was used in 18 patients with complicated median nerve lesions in this region. All patients had an uncomplicated postoperative course. Of 13 patients treated for posttraumatic median nerve neuromas, all but two had significant resolution of symptoms. When used as a vascularized flap, the flexor tendon synovium provides adequate protection of the median nerve. Flap dimensions and vascularity of this tissue make it an ideal local flap option when performing reoperative surgery on the median nerve.

  20. [APPLICATION OF V-Y ADVANCED SENSE-REMAINED POSTERIOR TIBIAL ARTERY PERFORATOR FLAP IN REPAIRING WOUND AROUND ANKLE].

    Science.gov (United States)

    Tang, Xiujun; Wang, Bo; Wei, Zairong; Wang, Dali; Han, Wenjie; Zhang, Wenduo; Li, Shujun

    2015-12-01

    OBJECTIVE To explore the feasibility and effectiveness of V-Y advanced sense-remained posterior tibial artery perforator flap in repairing wound around the ankle. METHODS Between March 2012 and January 2015, 11 patients with wounds around the ankle were treated by V-Y advanced sense-remained posterior tibial artery perforator flap. There were 6 males and 5 females with a median age of 37 years (range, 21-56 years). The causes were traffic accident injury in 3 cases, thermal injury in 2 cases, burn in 2 cases, iatrogenic wounds in 2 cases, and local contusion in 2 cases. The disease duration ranged from 1 to 3 weeks (mean, 2 weeks). Injury was located at the medial malleolus in 4 cases, at the lateral malleolus in 3 cases, and at the heel in 4 cases. All had exposure of bone, tendon, or plate. The defect area ranged from 4 cmx2 cm to 5 cmx3 cm; the area of the flap ranged from 11 cmx4 cm to 15 cmx6 cm. Necrosis of distal flap occurred in 1 case after operation; re-operation to amputate the posterior tibial artery was given and the wound was repaired by proximal skin graft. Light necrosis of distal end was observed in 2 cases, and wound healed at 3 weeks after dressing. And other flaps successfully survived, and primary healing of wounds were obtained. The patients were followed up 6-24 months (mean, 11 months). The flaps were good in color, texture, and appearance. The ankle joint had normal activity. At last follow-up, 10 cases restored fine sense, and 1 case restored protective feeling with posterior tibial artery advanced flap after amputation. V-Y advanced sense-remained posterior tibial artery perforator flap has the advantages of reliable blood supply, simple operation, good appearance, and sensory recovery. Therefore, it is an ideal method to repair wound around the ankle.

  1. Flapping-wing mechanical butterfly on a wheel

    Science.gov (United States)

    Godoy-Diana, Ramiro; Thiria, Benjamin; Pradal, Daniel

    2009-11-01

    We examine the propulsive performance of a flapping-wing device turning on a ``merry-go-round'' type base. The two-wing flapper is attached to a mast that is ball-bearing mounted to a central shaft in such a way that the thrust force produced by the wings makes the flapper turn around this shaft. The oscillating lift force produced by the flapping wings is aligned with the mast to avoid vibration of the system. A turning contact allows to power the motor that drives the wings. We measure power consumption and cruising speed as a function of flapping frequency and amplitude as well as wing flexibility. The design of the wings permits to change independently their flexibility in the span-wise and chord-wise directions and PIV measurements in various planes let us examine the vorticity field around the device. A complete study of the effect of wing flexibility on the propulsive performance of the system will be presented at the conference.

  2. [Clinical application of modified upper gluteal rhomboid fasciocutaneous flap in repairing sacrococcygeal pressure sores].

    Science.gov (United States)

    Jiang, Maohua; Yang, Xiaoliang; Wei, Bangmin; Li, Yinghao

    2012-03-01

    To investigate the method and effectiveness of repairing sacrococcygeal pressure sores with modified upper gluteal rhomboid fasciocutaneous flap. Between January 2004 and March 2011, 43 patients with sacrococcygeal pressure sores were treated. There were 25 males and 18 females with an average age of 63 years (range, 38-95 years). The disease duration was 3 months to 2 years and 6 months (mean, 8.5 months). The size of pressure sores ranged from 6 cm x 5 cm to 18 cm x 13 cm. According to the extent and lesion degree of pressure scores, 23 pressure sores were rated as degree III and 20 pressure sores as degree IV. The modified upper gluteal rhomboid flap was designed, one-side upper gluteal fasciocutaneous flaps were transplanted to repair sacrococcygeal pressure sores in 19 cases and two-side flaps in 24 cases. The size of one side flap ranged from 6.5 cm x 4.5 cm to 18.0 cm x 11.5 cm. Fluid under flap occurred in 1 case and edge necrosis of the flaps in 3 cases at 7 days after operation, which were cured after drainage and dressing change; the other flaps survived, and incisions healed by first intention. All patients were followed up 6 months to 3 years with an average of 11 months. Two patients relapsed at 5 months and 8 months, respectively; the other patients had no recurrence. The color of the flaps was normal, and the appearance and elasticity of the flaps were good. The modified upper gluteal rhomboid fasciocutaneous flap has the advantages of simple design and operation, less injury, and reliable effect in repairing sacrococcygeal pressure sores.

  3. Danish experience with free flaps in war wounds

    DEFF Research Database (Denmark)

    Holmgaard, Rikke; Duffy, Jonas; Warburg, Finn Edgar

    2016-01-01

    of 11). Flap-loss occurred in one patient, presumably due to leakage at the anastomotic site, which necessitated another free flap procedure. All patients received rehabilitation services following discharge from the inpatient unit, including prosthetic fitting. The mean follow-up time was 26 months....... CONCLUSIONS: This report is the first to detail the reconstructive procedures in soldiers treated at a public hospital in Denmark. The treatment of war casualties has not only been a challenge to the surgeons tasked with managing these devastating injuries, but also to Danish healthcare in general....... The outcome of multidisciplinary treatment, combining the expertise of various specialties, is highly encouraging. The rate of complications was low, and the aesthetic appearance of the reconstructed limbs and the functional recovery were satisfactory. We therefore recommend the use of free flaps...

  4. Detached Eddy Simulation of Flap Side-Edge Flow

    Science.gov (United States)

    Balakrishnan, Shankar K.; Shariff, Karim R.

    2016-01-01

    Detached Eddy Simulation (DES) of flap side-edge flow was performed with a wing and half-span flap configuration used in previous experimental and numerical studies. The focus of the study is the unsteady flow features responsible for the production of far-field noise. The simulation was performed at a Reynolds number (based on the main wing chord) of 3.7 million. Reynolds Averaged Navier-Stokes (RANS) simulations were performed as a precursor to the DES. The results of these precursor simulations match previous experimental and RANS results closely. Although the present DES simulations have not reached statistical stationary yet, some unsteady features of the developing flap side-edge flowfield are presented. In the final paper it is expected that statistically stationary results will be presented including comparisons of surface pressure spectra with experimental data.

  5. Optimization of morphing flaps based on fluid structure interaction modeling

    DEFF Research Database (Denmark)

    Barlas, Athanasios; Akay, Busra

    2018-01-01

    This article describes the design optimization of morphing trailing edge flaps for wind turbines with ‘smart blades’. A high fidelity Fluid Structure Interaction (FSI) simulation framework is utilized, comprised of 2D Finite Element Analysis (FEA) and Computational Fluid Dynamics (CFD) models....... A coupled aero-structural simulation of a 10% chordwise length morphing trailing edge flap for a 4 MW wind turbine rotor is carried out and response surfaces are produced with respect to the flap internal geometry design parameters for the design conditions. Surrogate model based optimization is applied...

  6. Evaluation of diode laser and stannous fluoride in the treatment of root sensitivity after access flap surgery: Randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Chetan Purushottam Raut

    2018-01-01

    Full Text Available Background: Postsurgical root sensitivity has always been an enigma to the periodontists. There is a plethora of evidence suggesting the presence of root sensitivity following periodontal flap surgical procedures. Thus, the aim of the present study was to compare and evaluate the effect of low-power diode lasers with and without topical application of stannous fluoride (SnF2 gel in the treatment of root sensitivity and also evaluate whether laser creates any placebo effect in the control group or not. Materials and Methods: Thirty patients participated in this study and 99 teeth were included. Root sensitivity was assessed for all groups with a Verbal Rating Scale (VRS. For each patient, the teeth were randomized into three groups. In the test Group I, sensitive teeth were treated with SnF2and diode laser. In the test Group II, sensitive teeth were irradiated with laser only. In the control group, no treatment was performed. Results: The mean ± standard deviation (SD score for VRS and Visual Analog Scale at baseline was not statistically significant (P > 0.05 between the three groups. After 15 min, statistical significant difference was seen in test Group I and test Group II, although no difference was found in the control group. At 15th day and 30th day, the mean ± SD scores were statistically significant (P < 0.05. Conclusion: Within the limitations of the study, it can be concluded that diode lasers alone and in combination with 0.4% SnF2was effective in the treatment of root sensitivity after access flap surgery.

  7. Risk factors for pedicled flap necrosis in hand soft tissue reconstruction: a multivariate logistic regression analysis.

    Science.gov (United States)

    Gong, Xu; Cui, Jianli; Jiang, Ziping; Lu, Laijin; Li, Xiucun

    2018-03-01

    Few clinical retrospective studies have reported the risk factors of pedicled flap necrosis in hand soft tissue reconstruction. The aim of this study was to identify non-technical risk factors associated with pedicled flap perioperative necrosis in hand soft tissue reconstruction via a multivariate logistic regression analysis. For patients with hand soft tissue reconstruction, we carefully reviewed hospital records and identified 163 patients who met the inclusion criteria. The characteristics of these patients, flap transfer procedures and postoperative complications were recorded. Eleven predictors were identified. The correlations between pedicled flap necrosis and risk factors were analysed using a logistic regression model. Of 163 skin flaps, 125 flaps survived completely without any complications. The pedicled flap necrosis rate in hands was 11.04%, which included partial flap necrosis (7.36%) and total flap necrosis (3.68%). Soft tissue defects in fingers were noted in 68.10% of all cases. The logistic regression analysis indicated that the soft tissue defect site (P = 0.046, odds ratio (OR) = 0.079, confidence interval (CI) (0.006, 0.959)), flap size (P = 0.020, OR = 1.024, CI (1.004, 1.045)) and postoperative wound infection (P < 0.001, OR = 17.407, CI (3.821, 79.303)) were statistically significant risk factors for pedicled flap necrosis of the hand. Soft tissue defect site, flap size and postoperative wound infection were risk factors associated with pedicled flap necrosis in hand soft tissue defect reconstruction. © 2017 Royal Australasian College of Surgeons.

  8. Peri-Vesical Fat Interposition Flap Reinforcement in High Vesico ...

    African Journals Online (AJOL)

    Background and Aim: The urinary bladder becomes small, contracted and is associated with excess pelvic fat in long standing cases of vesico-vaginal fistulas (VVFs). The aim of this new technique was to use this excess pelvic fat for harvesting an interposition flap. Materials and Methods: An interposition flap of peri-vesical ...

  9. Development of an Active Flow Control Technique for an Airplane High-Lift Configuration

    Science.gov (United States)

    Shmilovich, Arvin; Yadlin, Yoram; Dickey, Eric D.; Hartwich, Peter M.; Khodadoust, Abdi

    2017-01-01

    This study focuses on Active Flow Control methods used in conjunction with airplane high-lift systems. The project is motivated by the simplified high-lift system, which offers enhanced airplane performance compared to conventional high-lift systems. Computational simulations are used to guide the implementation of preferred flow control methods, which require a fluidic supply. It is first demonstrated that flow control applied to a high-lift configuration that consists of simple hinge flaps is capable of attaining the performance of the conventional high-lift counterpart. A set of flow control techniques has been subsequently considered to identify promising candidates, where the central requirement is that the mass flow for actuation has to be within available resources onboard. The flow control methods are based on constant blowing, fluidic oscillators, and traverse actuation. The simulations indicate that the traverse actuation offers a substantial reduction in required mass flow, and it is especially effective when the frequency of actuation is consistent with the characteristic time scale of the flow.

  10. Temporalis myofascial flap for primary cranial base reconstruction after tumor resection.

    Science.gov (United States)

    Eldaly, Ahmed; Magdy, Emad A; Nour, Yasser A; Gaafar, Alaa H

    2008-07-01

    To evaluate the use of the temporalis myofascial flap in primary cranial base reconstruction following surgical tumor ablation and to explain technical issues, potential complications, and donor site consequences along with their management. Retrospective case series. Tertiary referral center. Forty-one consecutive patients receiving primary temporalis myofascial flap reconstructions following cranial base tumor resections in a 4-year period. Flap survival, postoperative complications, and donor site morbidity. Patients included 37 males and 4 females ranging in age from 10 to 65 years. Two patients received preoperative and 18 postoperative radiation therapy. Patient follow-up ranged from 4 to 39 months. The whole temporalis muscle was used in 26 patients (63.4%) and only part of a coronally split muscle was used in 15 patients (36.6%). Nine patients had primary donor site reconstruction using a Medpor((R)) (Porex Surgical, Inc., Newnan, GA) temporal fossa implant; these had excellent aesthetic results. There were no cases of complete flap loss. Partial flap dehiscence was seen in six patients (14.6%); only two required surgical débridement. None of the patients developed cerebrospinal leaks or meningitis. One patient was left with complete paralysis of the temporal branch of the facial nerve. Three patients (all had received postoperative irradiation) developed permanent trismus. The temporalis myofascial flap was found to be an excellent reconstructive alternative for a wide variety of skull base defects following tumor ablation. It is a very reliable, versatile flap that is usually available in the operative field with relatively low donor site aesthetic and functional morbidity.

  11. Closure of Myelomeningocele Defects Using a Limberg Flap or Direct Repair

    Directory of Open Access Journals (Sweden)

    Jung-Hwan Shim

    2016-01-01

    Full Text Available BackgroundThe global prevalence of myelomeningocele has been reported to be 0.8–1 per 1,000 live births. Early closure of the defect is considered to be the standard of care. Various surgical methods have been reported, such as primary skin closure, local skin flaps, musculocutaneous flaps, and skin grafts. The aim of this study was to describe the clinical characteristics of myelomeningocele defects and present the surgical outcomes of recent cases of myelomeningocele at our institution.MethodsPatients who underwent surgical closure of myelomeningocele at our institution from January 2004 to December 2013 were included in this study. A retrospective chart review of their medical records was performed, and comorbidities, defect size, location, surgical procedures, complications, and the final results were analyzed.ResultsA total of 14 patients underwent surgical closure for myelomeningocele defects. Twelve cases were closed with direct skin repair, while two cases required local skin flaps to cover the skin defects. Three cases of infection occurred, requiring incision and either drainage or removal of allogenic materials. One case of partial flap necrosis occurred, requiring secondary revision using a rotational flap and a full-thickness skin graft. Despite these complications, all wounds eventually healed completely.ConclusionsMost myelomeningocele defects can be managed by direct skin repair alone. In cases of large defects, in which direct repair is not possible, local flaps may be used to cover the defect. Complications such as wound dehiscence and partial flap necrosis occurred in this study; however, all such complications were successfully managed with simple ancillary procedures.

  12. Funding analysis of bilateral autologous free-flap breast reconstructions in Australia.

    Science.gov (United States)

    Sinha, Shiba; Ruskin, Olivia; McCombe, David; Morrison, Wayne; Webb, Angela

    2015-08-01

    Bilateral breast reconstructions are being increasingly performed. Autologous free-flap reconstructions represent the gold standard for post-mastectomy breast reconstruction but are resource intensive. This study aims to investigate the difference between hospital reimbursement and true cost of bilateral autologous free-flap reconstructions. Retrospective analysis of patients who underwent bilateral autologous free-flap reconstructions at a single Australian tertiary referral centre was performed. Hospital reimbursement was determined from coding analysis. A true cost analysis was also performed. Comparisons were made considering the effect of timing, indication and complications of the procedure. Forty-six bilateral autologous free-flap procedures were performed (87 deep inferior epigastric perforators (DIEPs), four superficial inferior epigastric artery perforator flaps (SIEAs) and one muscle-sparing free transverse rectus abdominis myocutaneous flap (MS-TRAM)). The mean funding discrepancy between hospital reimbursement and actual cost was $12,137 ± $8539 (mean ± standard deviation (SD)) (n = 46). Twenty-four per cent (n = 11) of the cases had been coded inaccurately. If these cases were excluded from analysis, the mean funding discrepancy per case was $9168 ± $7453 (n = 35). Minor and major complications significantly increased the true cost and funding discrepancy (p = 0.02). Bilateral free-flap breast reconstructions performed in Australian public hospitals result in a funding discrepancy. Failure to be economically viable threatens the provision of this procedure in the public system. Plastic surgeons and hospital managers need to adopt measures in order to make these gold-standard procedures cost neutral. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Flapping inertia for selected rotor blades

    Science.gov (United States)

    Berry, John D.; May, Matthew J.

    1991-01-01

    Aerodynamics of helicopter rotor systems cannot be investigated without consideration for the dynamics of the rotor. One of the principal properties of the rotor which affects the rotor dynamics is the inertia of the rotor blade about its root attachment. Previous aerodynamic investigation have been performed on rotor blades with a variety of planforms to determine the performance differences due to blade planform. The blades tested for this investigation have been tested on the U.S. Army 2 meter rotor test system (2MRTS) in the NASA Langley 14 by 22 foot subsonic tunnel for hover performance. This investigation was intended to provide fundamental information on the flapping inertia of five rotor blades with differing planforms. The inertia of the bare cuff and the cuff with a blade extension were also measured for comparison with the inertia of the blades. Inertia was determined using a swing testing technique, using the period of oscillation to determine the effective flapping inertia. The effect of damping in the swing test was measured and described. A comparison of the flapping inertials for rectangular and tapered planform blades of approximately the same mass showed the tapered blades to have a lower inertia, as expected.

  14. A Novel Nipple Reconstruction Technique for Maintaining Nipple Projection: The Boomerang Flap

    Directory of Open Access Journals (Sweden)

    Young-Eun Kim

    2016-09-01

    Full Text Available Nipple-areolar complex (NAC reconstruction is the final step in the long journey of breast reconstruction for mastectomy patients. Successful NAC reconstruction depends on the use of appropriate surgical techniques that are simple and reliable. To date, numerous techniques have been used for nipple reconstruction, including contralateral nipple sharing and various local flaps. Recently, it has been common to utilize local flaps. However, the most common nipple reconstruction problem encountered with local flaps is the loss of nipple projection; there can be approximately 50% projection loss in reconstructed nipples over long-term follow-up. Several factors might contribute to nipple projection loss, and we tried to overcome these factors by performing nipple reconstructions using a boomerang flap technique, which is a modified C–V flap that utilizes the previous mastectomy scar to maintain long-term nipple projection.

  15. A Novel Nipple Reconstruction Technique for Maintaining Nipple Projection: The Boomerang Flap.

    Science.gov (United States)

    Kim, Young-Eun; Hong, Ki Yong; Minn, Kyung Won; Jin, Ung Sik

    2016-09-01

    Nipple-areolar complex (NAC) reconstruction is the final step in the long journey of breast reconstruction for mastectomy patients. Successful NAC reconstruction depends on the use of appropriate surgical techniques that are simple and reliable. To date, numerous techniques have been used for nipple reconstruction, including contralateral nipple sharing and various local flaps. Recently, it has been common to utilize local flaps. However, the most common nipple reconstruction problem encountered with local flaps is the loss of nipple projection; there can be approximately 50% projection loss in reconstructed nipples over long-term follow-up. Several factors might contribute to nipple projection loss, and we tried to overcome these factors by performing nipple reconstructions using a boomerang flap technique, which is a modified C-V flap that utilizes the previous mastectomy scar to maintain long-term nipple projection.

  16. Water Tunnel Studies of Dynamic Wing Flap Effects

    Science.gov (United States)

    2016-06-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited WATER TUNNEL...Master’s Thesis 4. TITLE AND SUBTITLE WATER TUNNEL STUDIES OF DYNAMIC WING FLAP EFFECTS 5. FUNDING NUMBERS 6. AUTHOR(S) Edgar E. González 7. PERFORMING...ABSTRACT (maximum 200 words ) The flow features developing over a two-element NACA 0012 airfoil, with the rear portion serving as a trailing edge flap

  17. Magnitude of Myocutaneous Flaps and Factors Associated With Loss of Volume in Oral Cancer Reconstructive Surgery.

    Science.gov (United States)

    Sakamoto, Yuki; Yanamoto, Souichi; Ota, Yoshihide; Furudoi, Shungo; Komori, Takahide; Umeda, Masahiro

    2016-03-01

    Myocutaneous flaps are often used to repair oral and maxillofacial defects after surgery for oral cancer; however, their volume decreases during the postoperative period. To facilitate treatment planning, the authors measured the extent of such postoperative flap volume loss and identified associated factors in patients who underwent oral reconstruction with myocutaneous flaps. The authors designed and performed a retrospective observational study of patients who underwent reconstructive procedures involving rectus abdominal myocutaneous (RAM) or pectoralis major myocutaneous (PMMC) flaps at Tokai University Hospital, Kobe University Hospital, or Nagasaki University Hospital from April 2009 through March 2013. Flap type and other clinical variables were examined as potential predictors of flap loss. The primary outcome was flap loss at 6 months postoperatively. Correlations between each potential predictor and the primary outcome were examined using multiple regression analysis. The subjects were 75 patients whose oral defects were reconstructed with RAM flaps (n = 57) or PMMC flaps (n = 18). RAM flaps exhibited a mean volume shrinkage of 22% at 6 months postoperatively, which was less than the 27.5% displayed by the PMMC flaps, but the difference was not important. Renal failure, previous surgery of the oral region, postoperative radiotherapy, and postoperative serum albumin level were found to be meaningful risk factors for postoperative flap volume loss. The results of this study suggest that larger flaps should be used in patients who possess these risk factors or are scheduled to undergo postoperative radiotherapy. Future studies should examine the utility of postoperative nutritional management for preventing flap volume loss. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Fournier?s gangrene - delayed pedicle flap based upon the anterior abdominal wall

    Directory of Open Access Journals (Sweden)

    Ania Sliwinski

    2014-06-01

    Full Text Available Introduction Fournier’s gangrene is a poly-microbial necrotizing fasciitis that involves the perineum and/or external genitalia. Urgent surgical debridement is well recognized as essential acute treatment yet unique challenges arise for plastic surgical reconstruction to obtain a complete functional recovery. This case describes a successful delayed pedicle flap repair based upon the anterior abdominal wall. Case description A 24 year old man was admitted to ICU ten days after elective circumcision with Fournier’s gangrene. He underwent a number of surgical debridements, and was referred for plastic surgical management. He had penile reconstruction using a random pattern abdominal flap, which was performed as a three stage procedure including flap vascular delay technique. Discussion Perineal and penile skin loss can be significant and is difficult to repair. Various techniques have been used to reconstruct lost tissue: skin grafts, transposition of the testes and spermatic cords to the thigh, flaps, and other types of pediculated myocutaneous flaps. Muscle flap reconstruction provides an environment that allows for complete regeneration of the urethral epithelium but is bulky and unsightly. Skin grafts contract and may produce painful and dysfunctional reconstructions. This novel technique produces a functional, and aesthetic reconstruction. Conclusion Penile skin recovery following Fournier’s gangrene recovery is problematic. This case demonstrates the functionality of a delayed flap repair using the anterior abdominal wall.

  19. Perforator chimerism for the reconstruction of complex defects: A new chimeric free flap classification system.

    Science.gov (United States)

    Kim, Jeong Tae; Kim, Youn Hwan; Ghanem, Ali M

    2015-11-01

    Complex defects present structural and functional challenges to reconstructive surgeons. When compared to multiple free flaps or staged reconstruction, the use of chimeric flaps to reconstruct such defects have many advantages such as reduced number of operative procedures and donor site morbidity as well as preservation of recipient vessels. With increased popularity of perforator flaps, chimeric flaps' harvest and design has benefited from 'perforator concept' towards more versatile and better reconstruction solutions. This article discusses perforator based chimeric flaps and presents a practice based classification system that incorporates the perforator flap concept into "Perforator Chimerism". The authors analyzed a variety of chimeric patterns used in 31 consecutive cases to present illustrative case series and their new classification system. Accordingly, chimeric flaps are classified into four types. Type I: Classical Chimerism, Type II: Anastomotic Chimerism, Type III: Perforator Chimerism and Type IV Mixed Chimerism. Types I on specific source vessel anatomy whilst Type II requires microvascular anastomosis to create the chimeric reconstructive solution. Type III chimeric flaps utilizes the perforator concept to raise two components of tissues without microvascular anastomosis between them. Type IV chimeric flaps are mixed type flaps comprising any combination of Types I to III. Incorporation of the perforator concept in planning and designing chimeric flaps has allowed safe, effective and aesthetically superior reconstruction of complex defects. The new classification system aids reconstructive surgeons and trainees to understand chimeric flaps design, facilitating effective incorporation of this important reconstructive technique into the armamentarium of the reconstruction toolbox. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Upper lip reconstruction using a pedicel superficial temporal artery flap

    Directory of Open Access Journals (Sweden)

    Mohammad M. Al-Qattan

    2018-01-01

    Conclusion: We demonstrate that the pedicle flap is much simpler than the free flap and is adequate for reconstruction of partial upper lip defects. We also demonstrate a good cosmetic and functional outcome; and highlight several technical points to ensure a satisfactory outcome.

  1. Capsaicin on the viability of random-pattern skin flaps in rats Capsaicina na viabilidade de retalhos isquêmicos randômicos em ratos

    Directory of Open Access Journals (Sweden)

    Gustavo Roberto de Godoy

    2010-10-01

    Full Text Available PURPOSE: To evaluate the effects of capsaicin on the viability of ischemic random-pattern skin flaps in rats. METHODS:Forty EPM1-Wistar rats were randomized into two groups of 20 animals each, the capsaicin group and the control group. A random-pattern skin flap measuring 10 x 4cm was raised and a plastic barrier was placed between the flap and the donor site. After the surgical procedure, the control group was treated with an inert vehicle in the form of a cream applied uniformly to a rayon bandage which, in turn, was applied to the surface of the skin flap. The capsaicin group was treated in the same way, but in this case capsaicin was added to the cream. This procedure was repeated for two consecutive days. RESULTS: There was a significantly smaller amount of flap necrosis in the capsaicin group (35.07% than in the control group (44.75% (p=0.035. CONCLUSION:Topical administration of capsaicin improved the viability of ischemic random-pattern skin flaps in rats.OBJETIVO: Avaliar os efeitos da capsaicina na viabilidade de retalhos isquêmicos randômicos em ratos. MÉTODOS: Quarenta ratos EPM1-Wistar foram distribuídos ao acaso em dois grupos de 20 animais cada, um grupo capsaicina e um grupo controle. Um retalho isquêmico randômico medindo 10 x 4cm foi elevado e uma barreira plástica foi colocada entre o retalho e a área doadora. Após o procedimento cirúrgico, o grupo controle foi tratado com um veículo inerte sob a forma creme aplicado uniformemente sobre uma atadura de rayon, que, por sua vez, foi aplicada à superfície do retalho. O grupo capsaicina foi tratado da mesma forma, porém a capsaicina foi adicionada ao creme. Este procedimento foi repetido por dois dias consecutivos. RESULTADOS: Houve uma quantidade significativamente menor da necrose do retalho no grupo capsaicina (35,07% comparado ao grupo controle (44,75% (p=0,035. CONCLUSÃO: A administração tópica da capsaicina melhorou a viabilidade de retalhos isquêmicos rand

  2. Free radial forearm flap versatility for the head and neck and lower extremity

    International Nuclear Information System (INIS)

    Chicarilli, Z.N.; Ariyan, S.; Cuono, C.B.

    1986-01-01

    Microsurgical techniques have developed numerous territories suitable for free tissue transfer. However, the demand for thin cutaneous resurfacing limits the choice of flaps available to the reconstructive microsurgeon. The radial forearm flap is a thin, axial, fasciocutaneous flap, offering pliable cutaneous resurfacing, with or without sensation. We have used 15 flaps to reconstruct defects in the head and neck and lower extremity resulting from burns, blunt and avulsive trauma, radiation necrosis, and tumor ablation. Two flaps (15 percent) developed venous congestion and were salvaged by reoperation. One retrograde flap (7.5 percent) developed partial necrosis from arterial insufficiency. Neural re-innervation was successful in two out of three patients in whom it was attempted. Two patients (15%) sustained minor donor site skin graft loss that healed secondarily. In our series of predominantly older patients the donor sites have been relatively inconspicuous at one year follow-up. A functional restoration was achieved in all patients

  3. The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome

    Directory of Open Access Journals (Sweden)

    Goussous IA

    2017-11-01

    Full Text Available Iyad A Goussous,1 Mohamed-Sameh El-Agha,1 Ahmed Awadein,1 Mohamed H Hosny,1 Alaa A Ghaith,2 Ahmed L Khattab2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, 2Faculty of Medicine, Alexandria University, Alexandria, Egypt Purpose: The purpose of this study was to determine the effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis (LASIK.Methods: This is a prospective controlled non-randomized, institutional study. Patients underwent either epi-LASIK with mitomycin (advanced surface ablation [ASA], thin-flap LASIK (90 µm head, or thick-flap LASIK (130 µm head. In ASA, the Moria Epi-K hydroseparator was used. LASIK flaps were created using the Moria M-2 mechanical microkeratome. The corneal hysteresis (CH and corneal resistance factor (CRF were measured preoperatively and 3 months after surgery, using the Ocular Response Analyzer®.Results: Ten patients (19 eyes underwent ASA, 11 patients (16 eyes underwent thin-flap LASIK, and 11 patients (16 eyes underwent thick-flap LASIK. The mean preoperative CH was 10.47±0.88, 10.52±1.4, and 11.28±1.4 mmHg (p=0.043, respectively, decreasing after surgery by 1.75±1.02, 1.66±1.00, and 2.62±1.03 mmHg (p=0.017. The mean reduction of CH per micron of central corneal ablation was 0.031, 0.023, and 0.049 mmHg/µm (p=0.005. Mean preoperative CRF was 10.11±1.28, 10.34±1.87, and 10.62±1.76 mmHg (p=0.66, decreasing after surgery by 2.33±1.35, 2.77±1.03, and 2.92±1.10 mmHg (p=0.308. The mean reduction of CRF per micron of central corneal ablation was 0.039, 0.040, and 0.051 mmHg/µm (p=0.112.Conclusion: Thick-flap LASIK caused a greater reduction of CH and CRF than thin-flap LASIK and ASA, although this was statistically significant only for CH. ASA and thin-flap LASIK were found to be biomechanically similar. Keywords: flap thickness ectasia, hysteresis, LASIK, surface ablation

  4. Reconstruction of Abdominal Wall of a Chronically Infected Postoperative Wound with a Rectus Abdominis Myofascial Splitting Flap

    Directory of Open Access Journals (Sweden)

    Sung Kyu Bae

    2013-01-01

    Full Text Available Background If a chronically infected abdominal wound develops, complications such asperitonitis and an abdominal wall defect could occur. This could prolong the patient’s hospitalstay and increase the possibility of re-operation or another infection as well. For this reason,a solution for infection control is necessary. In this study, surgery using a rectus abdominismuscle myofascial splitting flap was performed on an abdominal wall defect.Methods From 2009 to 2012, 5 patients who underwent surgery due to ovarian rupture,cesarean section, or uterine myoma were chosen. In each case, during the first week afteroperation, the wound showed signs of infection. Surgery was chosen because the wounds didnot resolve with dressing. Debridement was performed along the previous operation woundand dissection of the skin was performed to separate the skin and subcutaneous tissue fromthe attenuated rectus muscle and Scarpa’s fascial layers. Once the anterior rectus sheath andmuscle were adequately mobilized, the fascia and muscle flap were advanced medially sothat the skin defect could be covered for reconstruction.Results Upon 3-week follow-up after a rectus abdominis myofascial splitting flap operation,no major complication occurred. In addition, all of the patients showed satisfaction in termsof function and esthetics at 3 to 6 months post-surgery.Conclusions Using a rectus abdominis myofascial splitting flap has many esthetic andfunctional benefits over previous methods of abdominal defect treatment, and notably, itenabled infection control by reconstruction using muscle.

  5. Reconstruction of Abdominal Wall of a Chronically Infected Postoperative Wound with a Rectus Abdominis Myofascial Splitting Flap

    Directory of Open Access Journals (Sweden)

    Sung Kyu Bae

    2013-01-01

    Full Text Available BackgroundIf a chronically infected abdominal wound develops, complications such as peritonitis and an abdominal wall defect could occur. This could prolong the patient's hospital stay and increase the possibility of re-operation or another infection as well. For this reason, a solution for infection control is necessary. In this study, surgery using a rectus abdominis muscle myofascial splitting flap was performed on an abdominal wall defect.MethodsFrom 2009 to 2012, 5 patients who underwent surgery due to ovarian rupture, cesarean section, or uterine myoma were chosen. In each case, during the first week after operation, the wound showed signs of infection. Surgery was chosen because the wounds did not resolve with dressing. Debridement was performed along the previous operation wound and dissection of the skin was performed to separate the skin and subcutaneous tissue from the attenuated rectus muscle and Scarpa's fascial layers. Once the anterior rectus sheath and muscle were adequately mobilized, the fascia and muscle flap were advanced medially so that the skin defect could be covered for reconstruction.ResultsUpon 3-week follow-up after a rectus abdominis myofascial splitting flap operation, no major complication occurred. In addition, all of the patients showed satisfaction in terms of function and esthetics at 3 to 6 months post-surgery.ConclusionsUsing a rectus abdominis myofascial splitting flap has many esthetic and functional benefits over previous methods of abdominal defect treatment, and notably, it enabled infection control by reconstruction using muscle.

  6. Complete Lower Lip Reconstruction with a Large Lip Switch Flap and a Composite Modiolus Advancement Flap

    Directory of Open Access Journals (Sweden)

    Gudjon L. Gunnarsson, MD

    2017-12-01

    Full Text Available Summary:. Total loss of the lower lip is debilitating and poses a reconstructive challenge. Aiming to restore oral continence and function and also cosmetic appearance, a successful reconstruction has a huge impact on the quality of life for the individual patient. Early sources of local tissue rearrangement for lip reconstruction date back 3000 years, with earliest reports of lip switch procedures more than 2 centuries ago in Europe, when noma was still endemic in Europe, indicating that the anatomy was better understood by the barber surgeons of the past than we like to acknowledge. We are still faced with such challenging cases all over the world where resources are limited. Our current understanding of perforator anatomy and blood supply makes more frequent revisits to flaps of the past with modern advances. Innovative solutions are imperative for salvage, and old ideas tend to reappear when they prove to be useful. Herein, we describe in open access a new reconstructive method where we combined a large lip switch flap together with a composite advancement modiolus flap to reconstruct a whole lower lip and the donor defect of the upper lip all at once, a procedure that is simple to perform and works in settings where it is greatly needed.

  7. Perforator Flaps after Excision of Large Epidermal Cysts in the Buttocks

    Directory of Open Access Journals (Sweden)

    Sang Wha Kim

    2014-03-01

    Full Text Available Background Epidermal cysts are commonly occurring masses usually less than 5 cm in diameter, but in predisposed patients, epidermal cysts can grow relatively large due to chronic infection. Methods From June 2002 to July 2010, 17 patients received 19 regional perforator-based island flaps to cover defects due to the excision of large epidermal cysts (diameter >5 cm in the buttocks. Eight patients had diabetes, and seven had rheumatoid arthritis. The pedicles were not fully isolated to prevent spasms or twisting. Results All the flaps survived completely, except for one case with partial necrosis of the flap, which necessitated another perforator-based island flap for coverage. There were two cases of wound dehiscence, which were re-closed after meticulous debridement. There were no recurrences of the masses during follow-up periods of 8.1 months (range, 6-12 months. Conclusions In patients with large epidermal cysts and underlying medical disorders, regional perforator-based island flaps can be the solution to coverage of the defects after excision.

  8. Histological case-control study of peeling-induced skin changes by different peeling agents in surgically subcutaneous undermined skin flaps in facelift patients.

    Science.gov (United States)

    Gonser, P; Kaestner, S; Jaminet, P; Kaye, K

    2017-11-01

    A histological evaluation of peeling-induced skin changes in subcutaneous undermined preauricular facial skin flaps of nine patients was performed. There were three treatment groups: Trichloroacetic acid (TCA) 25%, TCA 40% and phenol/croton oil; one group served as control. Two independent evaluators determined the epidermal and dermal thickness and the depth of necrosis (micrometre). The percentual tissue damage due to the peeling was calculated, and a one-sample t-test for statistical significance was performed. On the basis of the histomorphological changes, peeling depth was classified as superficial, superficial-partial, deep-partial and full thickness chemical burn. The histological results revealed a progression of wound depth for different peeling agents without full thickness necrosis. TCA peels of up to 40% can be safely applied on subcutaneous undermined facial skin flaps without impairing the vascular patency, producing a predictable chemical burn, whereas deep peels such as phenol/croton oil peels should not be applied on subcutaneous undermined skin so as to not produce skin slough or necrosis by impairing vascular patency. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Understanding the unsteady aerodynamics of a revolving wing with pitching-flapping perturbations

    Science.gov (United States)

    Chen, Long; Wu, Jianghao; Zhou, Chao; Hsu, Shih-Jung; Eslam Panah, Azar; Cheng, Bo

    2017-11-01

    Revolving wings become less efficient for lift generation at low Reynolds numbers. Unlike flying insects using reciprocating revolving wings to exploit unsteady mechanisms for lift enhancement, an alternative that introduces unsteadiness through vertical flapping perturbation, is studied via experiments and simulations. Substantial drag reduction, linearly dependent on Strouhal number, is observed for a flapping-perturbed revolving wing at zero angle of attack (AoA), which can be explained by changes in the effective angle of attack and formation of reverse Karman vortex streets. When the AoA increases, flapping perturbations improve the maximum lift coefficient attainable by the revolving wing, with minor increases of drag or even minor drag reductions depending on Strouhal number and normalized flapping amplitude. When the pitching perturbations are further introduced, more substantial drag reduction and lift enhancement can be achieved in zero and positive AoAs, respectively. As the flapping-perturbed wings are less efficient compared with revolving wings in terms of power loading, the pitching-flapping perturbations can achieve a higher power loading at 20°AoA and thus have potential applications in micro air vehicle designs. This research was supported by NSF, DURIP, NSFC and Penn State Multi-Campus SEED Grant.

  10. The effect of chordwise flexibility on flapping foil propulsion in quiescent fluid

    Science.gov (United States)

    Shinde, Sachin; Arakeri, Jaywant

    2010-11-01

    Motivated to understand the role of wing flexibility of flying creatures during hovering, we experimentally study the effect of chordwise flexibility on the flow generated in quiescent fluid by a sinusoidally pitching rigid symmetrical foil with a flexible flap attached at the trailing edge. This foil produces a narrow, coherent jet containing reverse Karman vortex street, and a corresponding thrust. The thrust and flow is similar to that produced by a hovering bird or insect, however the mechanism seems to be different from known hovering mechanisms. Novelty of the present hovering mechanism is that the thrust generation is due to the coordinated pushing action of rigid foil and flexible flap. We identify the flow and vortex generation mechanism. This foil produces jet flows over a range of flapping frequencies and amplitudes. In contrast, the foil without flap i.e. with rigid trailing edge produces a weak, divergent jet that meanders randomly. Appending a flexible flap to the foil suppresses jet-meandering and strengthens the jet. Flexibility of flap is crucial in determining the flow structure. This study is useful in designing MAVs and thrusters.

  11. Long-term sensation in the medial plantar flap: a two-centre study.

    Science.gov (United States)

    Trevatt, Alexander E J; Filobbos, George; Ul Haq, Ata; Khan, Umraz

    2014-09-01

    Reconstruction in the foot and ankle region is challenging. This study aimed to quantify objective sensation return when a sensate medial plantar flap is used for like-for-like reconstruction of foot and ankle defects. Two-point discrimination (2PD) was assessed in flap and normal tissue at a minimum of 1 year post-operatively. A paired T-test assessed for significance. 8 patients were included. Mean 2PD in normal tissue and flap was 29 mm (SD: 11.9) and 33 mm (SD: 9.97) respectively with no statistically significant difference between the two (two-tailed p-value: 0.1898). Mean age was 53.2 years (range: 15-84). There was no statistically significant correlation between age and 2PD in flap tissue (r=0.6, p=0.15). This is the largest case series of its kind. Our results suggest that sensation in medial plantar flaps can return to near normal and demonstrate the important role the medial plantar flap plays in soft tissue reconstruction in this region. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  12. Peroneal island flap for wound coverage in complex injuries of the lower extremity

    Directory of Open Access Journals (Sweden)

    Fazal A

    2012-01-01

    Full Text Available Akil Fazal1, Haroon-ur-Rashid1, Tahseen Cheema21Section of Orthopedics, Department of Surgery, Aga Khan University, Karachi, Pakistan; 2Department of Orthopedics and Rehabilitation, University of New Mexico, Albuquerque, NM, USABackground: Complex injuries of the lower extremity pose a therapeutic challenge owing to limited availability of local soft tissue for coverage. One option in this region is the pedicled fasciocutaneous flap based on perforators of the peroneal artery. In this case series, we present our experience of the peroneal island pedicled flap for reconstruction of lower extremity wounds.Methods: Records of 18 cases of peroneal island flap admitted consecutively to the Section of Orthopedics at Aga Khan University Hospital from January 1996 to December of 2009 were studied and their outcomes determined.Results: The most common indication for coverage was open wounds due to a road traffic accident (n = 10, followed by burns (n = 3. The most common area exposed was the lower third of the leg followed by the middle third. The tibia was exposed in 11 patients. The flaps ranged in size from 35 cm2 to over 200 cm2. In 13 patients, the flaps healed uneventfully, while in the remaining five there was partial flap necrosis. In four of the latter patients, the residual wound healed with conservative measures only, but the fifth patient required further surgery to achieve acceptable coverage.Conclusion: The peroneal artery flap appears to be a simple, useful, and reliable flap in the armamentarium of the surgeon when planning soft tissue coverage of the lower extremity.Keywords: leg injuries, surgical flaps, lower extremity

  13. [A reverse vascular autograft finger island flap. A review of 15 cases and of the literature].

    Science.gov (United States)

    Adani, R; Marcuzzi, A; Busa, R; Pancaldi, G; Bathia, A; Caroli, A

    1995-01-01

    The authors discuss the indications for homodigital island flap with a reverse vascular pedicle. This flap is based on the anastomoses between the radial and ulnar digital arteries. These anastomotic branches lie between the posterior wall of the tendon sheath and the periosteum to form an arch and are named the "digitopalmar arches". The vascularization of the reverse homodigital island flap is derived by using the middle transverse palmar arch. This flap was performed successfully in 14 patients involving 15 fingers to resurface amputation of the distal phalanx. In 6 cases the flap was used as an "artery" flap, and in 9 cases as a "sensitive" homodigital island flap. The pedicle in these cases was neurovascular also containing the digital nerve. The sensitivity of the flap was obtained by neurorraphy between the transposed digital nerve of the flap and the receiving digital nerve of the recipient finger. This technique achieves cover of the tactile pad in one operative stage and provides well vascularized skin allowing early mobilization. Sensation of the flap can be restored rapidly when neurorraphy of the transposed digital nerve is performed.

  14. Flap Side Edge Liners for Airframe Noise Reduction

    Science.gov (United States)

    Jones, Michael G. (Inventor); Khorrami, Mehdi R. (Inventor); Choudhari, Meelan M. (Inventor); Howerton, Brian M. (Inventor)

    2014-01-01

    One or more acoustic liners comprising internal chambers or passageways that absorb energy from a noise source on the aircraft are disclosed. The acoustic liners may be positioned at the ends of flaps of an aircraft wing to provide broadband noise absorption and/or dampen the noise producing unsteady flow features, and to reduce the amount of noise generated due to unsteady flow at the inboard and/or outboard end edges of a flap.

  15. An investigation of unsteady 3-D effects on trailing edge flaps

    Directory of Open Access Journals (Sweden)

    E. Jost

    2017-05-01

    Full Text Available The present study investigates the impact of unsteady 3-D aerodynamic effects on a wind turbine blade with trailing edge flap by means of computational fluid dynamics (CFD. Harmonic oscillations are simulated on the DTU 10 MW rotor with a morphing flap of 10 % chord extent ranging from 70 to 80 % blade radius. The deflection frequency is varied in the range between 1 and 6 p. To quantify 3-D effects, rotor simulations are compared to 2-D airfoil computations and the 2-D theory by Theodorsen. It was found that the deflection of the flap on the 3-D rotor causes a complex wake development and induction which influences the loads over large parts of the blade. In particular, the rotor near wake with its trailing and shed vortex structures revealed a great impact. Trailing vorticity, a 3-D phenomenon, is caused by the gradient of bound circulation along the blade span. Shed vorticity originates from the temporal bound circulation gradient and is thus also apparent in 2-D. Both lead to an amplitude reduction and shed vorticity additionally to a hysteresis of the lift response with regard to the deflection signal in the flap section. A greater amplitude reduction and a less pronounced hysteresis is observed on the 3-D rotor compared to the 2-D airfoil case. Blade sections neighboring the flap experience, however, an opposing impact and hence partly compensate for the negative effect of trailing vortices in the flap section with respect to integral loads. Comparisons to steady flap deflections at the 3-D rotor revealed the high influence of dynamic inflow effects.

  16. Secondary free-flap reconstruction following ablation for acute invasive fungal sinusitis.

    Science.gov (United States)

    Allensworth, Jordan J; Troob, Scott H; Weaver, Tyler S; Gonzalez, Javier D; Petrisor, Daniel; Wax, Mark K

    2017-04-01

    Acute invasive fungal sinusitis (AIFS) is a frequently fatal infection for which extensive and debilitating surgical debridement is a mainstay of therapy. Resulting defects are often composite in nature, mandating free tissue-transfer reconstruction. Outcomes data for free flap reconstruction are limited. The purpose of this study was to examine surgical outcomes and survival in patients undergoing free flap transfer following invasive fungal sinusitis. Retrospective case series. Between 1995 and 2015, patients undergoing operative debridement for AIFS were identified. Surgical records were used to identify survivors of acute infection who subsequently underwent free flap reconstructive surgery. Patient demographics, cause of immune compromise, defect description, flap type, perioperative complications, indications for revision surgery, functional outcomes, and long-term survival were reviewed. Forty-four patients were treated for AIFS, of those, 30 (68%) survived acute infection. Ten patients underwent maxillectomy, six with orbital exenteration, and were designated candidates for reconstruction. Eight patients underwent reconstruction. Median time from debridement to reconstruction was 67.5 days. Flap types included latissimus dorsi, scapula, anterolateral thigh, rectus, radial forearm, and fibula. Median follow-up was 7.7 months. No perioperative complications were encountered, and all subjects remained disease-free, able to speak and eat normally without prosthetic supplementation. Seven patients (87%) are currently alive. Reconstruction of defects left by invasive fungal sinusitis using free-tissue transfer resulted in successful flap survival, with no disease recurrence for all defects and flap types reviewed. Survivors of AIFS are able to tolerate midface reconstruction, with favorable functional outcomes and survival rates. 4. Laryngoscope, 127:815-819, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Survey of large-amplitude flapping motions in the midtail current sheet

    Directory of Open Access Journals (Sweden)

    V. A. Sergeev

    2006-08-01

    Full Text Available We surveyed fast current sheet crossings (flapping motions over the distance range 10–30 RE in the magnetotail covered by the Geotail spacecraft. Since the local tilts of these dynamic sheets are large and variable in these events, we compare three different methods of evaluating current sheet normals using 4-s/c Cluster data and define the success criteria for the single-spacecraft-based method (MVA to obtain the reliable results. Then, after identifying more than ~1100 fast CS crossings over a 3-year period of Geotail observations in 1997–1999, we address their parameters, spatial distribution and activity dependence. We confirm that over the entire distance covered and LT bins, fast crossings have considerable tilts in the YZ plane (from estimated MVA normals which show a preferential appearance of one (YZ kink-like mode that is responsible for these severe current sheet perturbations. Their occurrence is highly inhomogeneous; it sharply increases with radial distance and has a peak in the tail center (with some duskward shift, resembling the occurrence of the BBFs, although there is no one-to-one local correspondence between these two phenomena. The crossing durations typically spread around 1 min and decrease significantly where the high-speed flows are registered. Based on an AE index superposed epoch study, the flapping motions prefer to appear during the substorm expansion phase, although a considerable number of events without any electrojet and auroral activity were also observed. We also present statistical distributions of other parameters and briefly discuss what could be possible mechanisms to generate the flapping motions.

  18. Intraoperative use of indocyanine green angiography for selecting the more reliable perforator of the anterolateral thigh flap: A comparison study.

    Science.gov (United States)

    La Padula, Simone; Hersant, Barbara; Meningaud, Jean Paul

    2018-03-30

    Anatomical variability of anterolateral thigh flap (ALT) perforators has been reported. The aim of this study is to assess if the use of intraoperative indocyanine green angiography (iICGA) can help surgeons to choose the ALT flap best perforator to be preserved. A retrospective study was conducted in 28 patients with open tibial fracture, following a road traffic crash, who had undergone ALT flap. Patients were classified into two groups: ICGA group (iICGA was used to select the more reliable perforator) and control group. The mean tissue loss size of the ICGA group (n = 13, 11 men and 2 women, mean age: 52 ± 6 years) was of 16.6 cm × 12.2 cm. The mean defect size of the control group (n = 15, 14 men and 1 women, mean age: 50 ± 5.52 years) was of 15.3 cm × 11.1 cm. Statistical analysis was performed to analyze and compare the results. ICGA allowed preserving only the most functional perforator, that provided the best ALT flap perfusion in 10 out of the 13 cases (77%). ICGA allowed a significant operative time reduction (160 ± 23 vs. 202 ± 48 minutes; P < .001). One case of distal necrosis was observed in the ICGA group (mean follow-up 12.3 months), while partial skin necrosis occurred in three cases of the control group (mean follow-up 13.1 months); P = .35. No additional coverage was required and a successful bone healing was observed in both groups. These findings suggest that iICGA is an effective method that allows to select the most reliable ALT flap perforators and to reduce operative time. © 2018 Wiley Periodicals, Inc.

  19. Oesophageal flap valvuloplasty and wrapping suturing prevent gastrooesophageal reflux disease in dogs after oesophageal anastomosis

    Science.gov (United States)

    Dai, Ji-Gang; Liu, Quan-Xing; Den, Xu-Feng; Min, Jia-Xin

    2014-01-01

    AIM: To examine the efficiency of oesophageal flap valvuloplasty and wrapping suturing technique in decreasing the rate of postoperative gastrooesophageal reflux disease in a dog model. METHODS: We operated on 10 dogs in this study. First, we resected a 5-cm portion of the distal oesophagus and then restored the continuity of the oesophageal and gastric walls by end-to-end anastomosis. A group of five dogs was subjected to the oesophageal flap valvuloplasty and wrapping suturing technique, whereas another group (control) of five dogs was subjected to the stapling technique after oesophagectomy. The symptom of gastrooesophageal reflux was recorded by 24-h pH oesophageal monitoring. Endoscopy and barium swallow examination were performed on all dogs. Anastomotic leakage was observed by X-ray imaging, whereas benign anastomotic stricture and mucosal damage were observed by endoscopy. RESULTS: None of the 10 dogs experienced anastomotic leakage after oesophagectomy. Four dogs in the new technology group resumed regular feeding, whereas only two of the dogs in the control group tolerated solid food intake. pH monitoring demonstrated that 25% of the dogs in the experimental group exhibited reflux and that none had mucosal damage consistent with reflux. Conversely, both reflux and mucosal damage were observed in all dogs in the control group. CONCLUSION: The oesophageal flap valvuloplasty and wrapping suturing technique can improve the postoperative quality of life through the long-term elimination of reflux oesophagitis and decreased stricture formation after primary oesophageal anastomosis. PMID:25516655

  20. Lift Production on Flapping and Rotary Wings at Low Reynolds Numbers

    Science.gov (United States)

    2016-02-26

    AFRL-AFOSR-VA-TR-2016-0098 Flapping and Rotary Wing Lift at Low Reynolds Number Anya Jones MARYLAND UNIV COLLEGE PARK Final Report 02/26/2016...Lift Production on Flapping and Rotary Wings at Low Reynolds Numbers (YIP) 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA9550-12-1-0251 5c. PROGRAM...necessary if the abstract is to be limited. Standard Form 298 Back (Rev. 8/98) Lift Production on Flapping and Rotary Wings at Low Reynolds Numbers