WorldWideScience

Sample records for active protection system

  1. Aging assessment for active fire protection systems

    International Nuclear Information System (INIS)

    Ross, S.B.; Nowlen, S.P.; Tanaka, T.

    1995-06-01

    This study assessed the impact of aging on the performance and reliability of active fire protection systems including both fixed fire suppression and fixed fire detection systems. The experience base shows that most nuclear power plants have an aggressive maintenance and testing program and are finding degraded fire protection system components before a failure occurs. Also, from the data reviewed it is clear that the risk impact of fire protection system aging is low. However, it is assumed that a more aggressive maintenance and testing program involving preventive diagnostics may reduce the risk impact even further

  2. Physical protection system using activated barriers

    International Nuclear Information System (INIS)

    Timm, R.E.; Zinneman, T.E.; Haumann, J.R.; Flaugher, H.A.; Reigle, D.L.

    1984-03-01

    The Argonne National Laboratory has recently installed an activated barrier, the Access Denial System, to upgrade its security. The technology of this system was developed in the late 70's by Sandia National Laboratory-Albuquerque. The Argonne National Laboratory is the first Department of Energy facility to use this device. Recent advancements in electronic components provide the total system support that makes the use of an activated barrier viable and desirable. The premise of an activated barrier is that it is deployed after a positive detection of an adversary is made and before the adversary can penetrate vital area. To accomplish this detection, sophisticated alarms, assessment, and communications must be integrated into a system that permits a security inspector to make a positive evaluation and to activate the barrier. The alarm sensor locations are selected to provide protection in depth. Closed circuit television is used with components that permit multiple video frames to be stored for automated, priority-based playback to the security inspector. Further, algorithms permit look-ahead surveillance of vital areas so that the security inspector can activate the access denial system in a timely manner and not be restricted to following the adversaries' penetration path(s)

  3. Active Wireless Temperature Sensors for Aerospace Thermal Protection Systems

    Science.gov (United States)

    Milos, Frank S.; Karunaratne, K.; Arnold, Jim (Technical Monitor)

    2002-01-01

    Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles in order to reduce life-cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to advance inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and Korteks to develop active wireless sensors that can be embedded in the thermal protection system to monitor sub-surface temperature histories. These devices are thermocouples integrated with radio-frequency identification circuitry to enable acquisition and non-contact communication of temperature data through aerospace thermal protection materials. Two generations of prototype sensors are discussed. The advanced prototype collects data from three type-k thermocouples attached to a 2.54-cm square integrated circuit.

  4. Laser Range Profiling for Active Protection System Target Classification and Aim-Point Selection

    National Research Council Canada - National Science Library

    Jones, Michael

    2004-01-01

    ...) is currently developing the Close-In Active Protection System (CIAPS). The distinguishing capability of CIAPS is its ability to provide self-protection against missiles and projectiles launched at close range...

  5. Nitroxide delivery system for Nrf2 activation and skin protection.

    Science.gov (United States)

    Ben Yehuda Greenwald, Maya; Frušić-Zlotkin, Marina; Soroka, Yoram; Sasson, Shmuel Ben; Bianco-Peled, Havazelet; Bitton, Ronit; Kohen, Ron

    2015-08-01

    Cyclic nitroxides are a large group of compounds composed of diverse stable radicals also known as synthetic antioxidants. Although nitroxides are valuable for use in several skin conditions, in in vivo conditions they have several drawbacks, such as nonspecific dispersion in normal tissue, preferential renal clearance and rapid reduction of the nitroxide to the corresponding hydroxylamine. However, these drawbacks can be easily addressed by encapsulating the nitroxides within microemulsions. This approach would allow nitroxide activity and therefore their valuable effects (e.g. activation of the Keap1-Nrf2-EpRE pathway) to continue. In this work, nitroxides were encapsulated in a microemulsion composed of biocompatible ingredients. The nanometric size and shape of the vehicle microemulsion and nitroxide microemulsion displayed high similarity, indicating that the stability of the microemulsions was preserved. Our studies demonstrated that nitroxide microemulsions were more potent inducers of the Keap1-Nrf2-EpRE pathway than the free nitroxides, causing the activation of phase II enzymes. Moreover, microemulsions containing nitroxides significantly reduced UVB-induced cytotoxicity in the skin. Understanding the mechanism of this improved activity may expand the usage of many other Nrf2 modulating molecules in encapsulated form, as a skin protection strategy against oxidative stress-related conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Army and Marine Corps Active Protection System (APS) Efforts

    Science.gov (United States)

    2016-08-30

    2012 report also provides a comprehensive treatment of the “soft kill” features of the APS: Soft-kill countermeasures include infrared jammers, laser ... spot imitators, and radar jammers. They may prevent missile guidance from remaining locked onto the GCV [Ground Combat Vehicle], 18 protecting the...For example, a millimeter wave radar jammer will not work against an infrared tracker . Furthermore, when jammers offer umbrella coverage (broadband

  7. Appraisal of Passive and Active Fire Protection Systems in Student’s Accommodation

    Directory of Open Access Journals (Sweden)

    Ismail I.

    2014-03-01

    Full Text Available Fire protection systems are very important systems that must be included in buildings. They have a great significance in reducing or preventing the occurrences of fire. This paper presents an assessment of fire protection systems in student’s accommodation. Student accommodation is a particular type of building that provides shelter for students at University. In addition, it is also supposed to be an attractive environment, conducive to learning, and importantly, safe for occupation. The fire safety of occupants in a building, must be in accordance with the requirements of the building’s code. Therefore, the design of the building must comply with the Uniform Building By-Law (UBBL 1984 of Malaysia, and provide all of the required safety features. This paper describes the findings from investigations of passive and active fire protection systems installed in buildings, based on fire safety requirements, UBBL (1984.

  8. Advanced Worker Protection System

    International Nuclear Information System (INIS)

    1996-04-01

    The Advanced Worker Protection System (AWPS) is a liquid-air-based, self-contained breathing and cooling system with a duration of 2 hrs. AWPS employs a patented system developed by Oceaneering Space Systems (OSS), and was demonstrated at their facility in Houston, TX as well as at Kansas State University, Manhattan. The heart of the system is the life-support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack is combined with advanced protective garments, an advanced liquid cooling garment (LCG), a respirator, and communications and support equipment. The prototype unit development and testing under Phase 1 has demonstrated that AWPS has the ability to meet performance criteria. These criteria were developed with an understanding of both the AWPS capabilities and the DOE decontamination and decommissioning (D and D) activities protection needs

  9. Development of quench protection system for HTS coils by active power method

    International Nuclear Information System (INIS)

    Nanato, N.; Tsumiyama, Y.; Kim, S.B.; Murase, S.; Seong, K.-C.; Kim, H.-J.

    2007-01-01

    Recently, HTS coils have been developed for electric power apparatuses. In superconducting coils, local and excessive joule heating may give damage to the superconducting windings when a quench occurs and therefore it is essential that the quench is detected quickly and precisely so that the coils can be safely discharged. Resistive voltage measurement method is universally used for the quench detection, however, it is vulnerable to an electromagnetic noise which causes insufficient quench detection and at least needs a central voltage tap in windings. In a large superconducting coil, a lead-wire from the central voltage tap may cause a short-circuit when high voltage will be applied. In this paper, we present a quench protection system based on the active power method which detects a quench by measuring the instantaneous active power generated in a superconducting coil. The protection system based on this method is very strong against to the noise and no more needs a central voltage tap. The performance of system developed by us is confirmed by using test coil wound with Bi-2223 HTS tapes

  10. Soil microflora and enzyme activities in rhizosphere of Transgenic Bt cotton hybrid under different intercropping systems and plant protection schedules

    Science.gov (United States)

    Biradar, D. P.; Alagawadi, A. R.; Basavanneppa, M. A.; Udikeri, S. S.

    2012-04-01

    Field experiments were conducted over three rainy seasons of 2005-06 to 2007-08 on a Vertisol at Dharwad, Karnataka, India to study the effect of intercropping and plant protection schedules on productivity, soil microflora and enzyme activities in the rhizosphere of transgenic Bt cotton hybrid. The experiment consisted of four intercropping systems namely, Bt cotton + okra, Bt cotton + chilli, Bt cotton + onion + chilli and Bt cotton + redgram with four plant protection schedules (zero protection, protection for Bt cotton, protection for intercrop and protection for both crops). Observations on microbial populations and enzyme activities were recorded at 45, 90, 135 and 185 (at harvest) days after sowing (DAS). Averaged over years, Bt cotton + okra intercropping had significantly higher total productivity than Bt cotton + chilli and Bt cotton + redgram intercropping system and was similar to Bt cotton + chilli + onion intercropping system. With respect to plant protection schedules for bollworms, protection for both cotton and intercrops recorded significantly higher yield than the rest of the treatments. Population of total bacteria, fungi, actinomycetes, P-solubilizers, free-living N2 fixers as well as urease, phosphatase and dehydrogenase enzyme activities increased up to 135 days of crop growth followed by a decline. Among the intercropping systems, Bt cotton + chilli recorded significantly higher population of microorganisms and enzyme activities than other cropping systems. While Bt cotton with okra as intercrop recorded the least population of total bacteria and free-living N2 fixers as well as urease activity. Intercropping with redgram resulted in the least population of actinomycetes, fungi and P-solubilizers, whereas Bt cotton with chilli and onion recorded least activities of dehydrogenase and phosphatase. Among the plant protection schedules, zero protection recorded maximum population of microorganisms and enzyme activities. This was followed by the

  11. Advanced worker protection system

    International Nuclear Information System (INIS)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-01-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system maintenance, and dramatically improve worker productivity through longer duration work cycles. Phase I of the project has resulted in a full scale prototype Advanced Worker Protection Ensemble (AWPE, everything the worker will wear), with sub-scale support equipment, suitable for integrated testing and preliminary evaluation. Phase II will culminate in a full scale, certified, pre-production AWPS and a site demonstration

  12. Advanced worker protection system

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-12-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system maintenance, and dramatically improve worker productivity through longer duration work cycles. Phase I of the project has resulted in a full scale prototype Advanced Worker Protection Ensemble (AWPE, everything the worker will wear), with sub-scale support equipment, suitable for integrated testing and preliminary evaluation. Phase II will culminate in a full scale, certified, pre-production AWPS and a site demonstration.

  13. Advanced worker protection system

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, B.; Duncan, P.; Myers, J. [Oceaneering Space Systems, Houston, TX (United States)

    1995-10-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project describes the development of an Advanced Worker Protection System (AWPS) which will include a life-support backpack with liquid air for cooling and as a supply of breathing gas, protective clothing, respirators, communications, and support equipment.

  14. Advanced worker protection system

    International Nuclear Information System (INIS)

    Caldwell, B.; Duncan, P.; Myers, J.

    1995-01-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project describes the development of an Advanced Worker Protection System (AWPS) which will include a life-support backpack with liquid air for cooling and as a supply of breathing gas, protective clothing, respirators, communications, and support equipment

  15. Protective garment ventilation system

    Science.gov (United States)

    Lang, R. (Inventor)

    1970-01-01

    A method and apparatus for ventilating a protective garment, space suit system, and/or pressure suits to maintain a comfortable and nontoxic atmosphere within is described. The direction of flow of a ventilating and purging gas in portions of the garment may be reversed in order to compensate for changes in environment and activity of the wearer. The entire flow of the ventilating gas can also be directed first to the helmet associated with the garment.

  16. Machine protection systems

    CERN Document Server

    Macpherson, A L

    2010-01-01

    A summary of the Machine Protection System of the LHC is given, with particular attention given to the outstanding issues to be addressed, rather than the successes of the machine protection system from the 2009 run. In particular, the issues of Safe Machine Parameter system, collimation and beam cleaning, the beam dump system and abort gap cleaning, injection and dump protection, and the overall machine protection program for the upcoming run are summarised.

  17. Changing the paradigm: a radiation protection model for utilizing active systems in homeland defense applications

    International Nuclear Information System (INIS)

    Hertel, Nolan E.; Shannon, Michael P.

    2008-01-01

    Full text: The emerging threat from non-state actors and terrorist organizations openly asserting the use of weapons of mass destruction has led to an increased global emphasis on homeland defense and national security. The threat is real and thus many states are spending large amounts of resources to combat the problem. Issues such as unsecured radioactive sources, illicit movement of nuclear material, the use of radioactive sources in the medical and industrial sectors are just a few of the areas being examined. Countering these threats involves a major paradigm shift in the manner in which radiation is viewed. Radiation-based technologies are playing a key role in this emerging area from the development of new passive detection modalities to the use of active systems for detecting illicit materials. The screening of humans, baggage and cargo present overwhelming challenges. With these developments comes the concern from both governmental agencies and the public as to the safety of such systems. This paper will explore one such modality; the employment of radiation-based illicit material detection systems. The authors will present a review of the international (IAEA) and US regulatory and statutory documents as well as recommendations from scientific bodies such as the International Commission on Radiological Protection and the International Commission on Radiation Units and Measurements. This review coupled with sound scientific data are used to develop a proposed framework for the future employment of active systems for homeland defense applications. Issues considered include the ability to effectively measure and/or predict dose, is the As Low As Reasonably Achievable (ALARA) concept appropriate?, how much dose should be allowed relative to national security?, where does the linear-no-threshold hypothesis fit in? The authors use this analysis to develop a model which examines the trade-offs and cost-benefits in using the proposed systems. The major findings of

  18. FIRE PROTECTION SYSTEMS AND TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Aristov Denis Ivanovich

    2016-03-01

    Full Text Available The All-Russian Congress “Fire Stop Moscow” was de-voted to the analysis of the four segments of the industry of fire protection systems and technologies: the design of fire protec-tion systems, the latest developments and technologies of active and passive fire protection of buildings, the state and the devel-opment of the legal framework, the practice of fire protection of buildings and structures. The forum brought together the repre-sentatives of the industry of fire protection systems, scientists, leading experts, specialists in fire protection and representatives of construction companies from different regions of Russia. In parallel with the Congress Industrial Exhibition of fire protection systems, materials and technology was held, where manufacturers presented their products. The urgency of the “Fire Stop Moscow” Congress in 2015 organized by the Congress Bureau ODF Events lies primarily in the fact that it considered the full range of issues related to the fire protection of building and construction projects; studied the state of the regulatory framework for fire safety and efficiency of public services, research centers, private companies and busi-nesses in the area of fire safety. The main practical significance of the event which was widely covered in the media space, was the opportunity to share the views and information between management, science, and practice of business on implementing fire protection systems in the conditions of modern economic relations and market realities. : congress, fire protection, systems, technologies, fire protection systems, exhibition

  19. Quality Management System Improves Effectiveness and Quality of Activities of Radiation Protection Regulatory Body in Lithuania

    International Nuclear Information System (INIS)

    Mastauskas, A.

    2016-01-01

    Processes of creation of quality management system (QMS) in regulatory body in radiation protection field – Radiation Protection Centre (RPC) and the benefit of this system to ensure the quality of the performance of functions are described. RPC QMS compliant with ISO 9001:2008 standard and in line with the requirements of the IAEA GSR- 3 document. It allowed achieving a new quality of works carried out by RPC. Because creation and introduction of the QMS is a continuous process, the QMS of RPC is continually renewed and new procedures are developed.

  20. Oral vaccination with heat inactivated Mycobacterium bovis activates the complement system to protect against tuberculosis.

    Directory of Open Access Journals (Sweden)

    Beatriz Beltrán-Beck

    Full Text Available Tuberculosis (TB remains a pandemic affecting billions of people worldwide, thus stressing the need for new vaccines. Defining the correlates of vaccine protection is essential to achieve this goal. In this study, we used the wild boar model for mycobacterial infection and TB to characterize the protective mechanisms elicited by a new heat inactivated Mycobacterium bovis vaccine (IV. Oral vaccination with the IV resulted in significantly lower culture and lesion scores, particularly in the thorax, suggesting that the IV might provide a novel vaccine for TB control with special impact on the prevention of pulmonary disease, which is one of the limitations of current vaccines. Oral vaccination with the IV induced an adaptive antibody response and activation of the innate immune response including the complement component C3 and inflammasome. Mycobacterial DNA/RNA was not involved in inflammasome activation but increased C3 production by a still unknown mechanism. The results also suggested a protective mechanism mediated by the activation of IFN-γ producing CD8+ T cells by MHC I antigen presenting dendritic cells (DCs in response to vaccination with the IV, without a clear role for Th1 CD4+ T cells. These results support a role for DCs in triggering the immune response to the IV through a mechanism similar to the phagocyte response to PAMPs with a central role for C3 in protection against mycobacterial infection. Higher C3 levels may allow increased opsonophagocytosis and effective bacterial clearance, while interfering with CR3-mediated opsonic and nonopsonic phagocytosis of mycobacteria, a process that could be enhanced by specific antibodies against mycobacterial proteins induced by vaccination with the IV. These results suggest that the IV acts through novel mechanisms to protect against TB in wild boar.

  1. ADVANCED WORKER PROTECTION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Judson Hedgehock

    2001-03-16

    From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long as workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify

  2. ADVANCED WORKER PROTECTION SYSTEM

    International Nuclear Information System (INIS)

    Judson Hedgehock

    2001-01-01

    From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long as workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify

  3. 78 FR 15876 - Activation of Ice Protection

    Science.gov (United States)

    2013-03-13

    ...-0675; Amendment No. 121-363] RIN 2120-AJ43 Activation of Ice Protection AGENCY: Federal Aviation... On August 22, 2011, the FAA published a final rule entitled, ``Activation of Ice Protection,'' (76 FR... protection system. The FAA inadvertently wrote the amendatory language incorrectly to say that we were...

  4. Smart cathodic protection systems

    NARCIS (Netherlands)

    Polder, R.B.; Leggedoor, J.; Schuten, G.; Sajna, S.; Kranjc, A.

    2010-01-01

    Cathodic protection delivers corrosion protection in concrete structures exposed to aggressive environments, e.g. in de-icing salt and marine climates. Working lives of a large number of CP systems are at least more than 13 years and probably more than 25 years, provided a minimum level of

  5. Buffer moisture protection system

    International Nuclear Information System (INIS)

    Ritola, J.; Peura, J.

    2013-11-01

    With the present knowledge, bentonite blocks have to be protected from the air relative humidity and from any moisture leakages in the environment that might cause swelling of the bentonite blocks during the 'open' installation phase before backfilling. The purpose of this work was to design the structural reference solution both for the bottom of the deposition hole and for the buffer moisture protection and dewatering system with their integrated equipment needed in the deposition hole. This report describes the Posiva's reference solution for the buffer moisture protection system and the bottom plate on basis of the demands and functional requirements set by long-term safety. The reference solution with structural details has been developed in research work made 2010-2011. The structural solution of the moisture protection system has not yet been tested in practice. On the bottom of the deposition hole a copper plate which protects the lowest bentonite block from the gathered water is installed straight to machined and even rock surface. The moisture protection sheet made of EPDM rubber is attached to the copper plate with an inflatable seal. The upper part of the moisture protection sheet is fixed to the collar structures of the lid which protects the deposition hole in the disposal tunnel. The main function of the moisture protection sheet is to protect bentonite blocks from the leaking water and from the influence of the air humidity at their installation stage. The leaking water is controlled by the dewatering and alarm system which has been integrated into the moisture protection liner. (orig.)

  6. System level ESD protection

    CERN Document Server

    Vashchenko, Vladislav

    2014-01-01

    This book addresses key aspects of analog integrated circuits and systems design related to system level electrostatic discharge (ESD) protection.  It is an invaluable reference for anyone developing systems-on-chip (SoC) and systems-on-package (SoP), integrated with system-level ESD protection. The book focuses on both the design of semiconductor integrated circuit (IC) components with embedded, on-chip system level protection and IC-system co-design. The readers will be enabled to bring the system level ESD protection solutions to the level of integrated circuits, thereby reducing or completely eliminating the need for additional, discrete components on the printed circuit board (PCB) and meeting system-level ESD requirements. The authors take a systematic approach, based on IC-system ESD protection co-design. A detailed description of the available IC-level ESD testing methods is provided, together with a discussion of the correlation between IC-level and system-level ESD testing methods. The IC-level ESD...

  7. Study of passive and active protection system for the SSC [Superconducting Super Collider] R ampersand D dipole magnet

    International Nuclear Information System (INIS)

    Lopez, G.; Snitchler, G.

    1990-06-01

    A comparative study of Passive versus Active Protection Systems is made using the computer programs SSC*, designed especially for this proposal. These programs track the quench evolution of each conductor independently, the axial quench velocity is given by a modified expression which correctly fits the experimental data, the phenomenological turn-to-turn transversal quench propagation is considered as an input parameter of the programs. The results of the simulations for a 40 mm dipole indicate that a single dipole is widely self-protected, which suggests that a Cold Diode Passive Protection System is a safe method to protect the magnet (no heaters are needed), and also that two or three magnets (Conceptual Design) will be a safe Active Protection System is the heater-time-delay to cause other quenching is sufficiently brief (τ h < 50 ms). Assuming the same turn-to-turn quench propagation for the 50 mm SSC R ampersand D Dipole Magnet, the predictions for this magnet will have much lower axial quench velocity and the above results will be still valid for this new magnet. 10 refs., 30 figs

  8. Power system protection

    International Nuclear Information System (INIS)

    Venkata, S.S.; Damborg, M.J.; Jampala, A.K.

    1991-01-01

    Power systems of the 21st century will be more modern, and complex, utilizing the latest available technologies. At the same time, generating plants will have to operate with minimal spinning margins and energy transportation has to take place at critical levels due to environmental and economical constraints. These factors dictate that the power systems be protected with optimum sensitivity, selectivity and time of operation to assure maximum reliability, and security at minimal cost. With an increasing role played by digital computers in every aspect of protection, it is important to take a critical and fresh look at the art and science of relaying and protection. The main objective of this paper is to review the past, present and future of power system protection from a software point of view

  9. Depth protection system

    International Nuclear Information System (INIS)

    Arita, Setsuo; Izumi, Shigeru; Suzuki, Satoru; Noguchi, Atomi.

    1988-01-01

    Purpose: To previously set a nuclear reactor toward safety side by the reactor scram if an emergency core cooling system is failed to operate. Constitution If abnormality occurs in an emergency core cooling system or an aqueous boric acid injection system, a reactor protection system is operated and, if the reactor protection system shows an abnormal state, a control rod withdrawal inhibition system is operated as a fundamental way. For instance, when the driving power source voltage for the emergency core cooling system is detected and, if it is lower than a predetermined value, the reactor protection system is operated. Alternatively, if the voltage goes lower than the predetermined value, the control rod withdrawal is inhibited. In addition, stopping for the feedwater system is inhibited. Further, integrity of the driving means for the emergency core cooling system is positively checked and the protection function is operated depending on the result of check. Since the nuclear reactor can be set toward the safety side even if the voltage for the driving power source of the aqueous boric acid injection system is lower than a predetermined value, the reactor safety can further be improved. (Horiuchi, T.)

  10. Challenges of the Unemployment Protection System and Active Policies in Spain

    Directory of Open Access Journals (Sweden)

    Del Pino, Eloísa

    2015-02-01

    Full Text Available The NorSpaR project aims to analyse the main public policy initiatives by which Norway and Spain cope with the new social and economic challenges derived from the so-called New Social Risks (NSR. Although both countries present significant differences in their institutional settings (such as Spanish EU membership, or its belonging to diverse welfare regimes types (Norway is generally included in the Nordic regime, while Spain is part of the Mediterranean one, both countries share a common interest in addressing the aforementioned challenges while maintaining social cohesion. In the last decade, governments in both countries have tried to respond to those challenges by reforming their labour markets, adapting their unemployment schemes, as well as their gender, family and long-term care policies. The analysis covered in this project includes three areas of public policy addressing NSR. First, dependency is one of the most daunting challenges for post-industrial societies experiencing population ageing and with an increasing number of frail people in need of care. This situation is forcing governments to rethink their long-term care policies. Second, family and gender public programs need to respond to the growing difficulties of families in reconciling professional and family life. Third, in the transition to a post-industrial order, and in a context of mass unemployment, social protection systems have a renewed prominence. Along with the so-called passive policies offering financial support to the unemployed, active labour market policies are geared to put people back into work. In our analysis we try to find answers to the following questions: What are the challenges that each of these policies have been trying to address in recent years? How have these policies evolved? What kinds of reforms have been implemented, and which ones have been neglected? Have the policy goals and targets of welfare programs been modified in any significant way

  11. Reactor protection system

    International Nuclear Information System (INIS)

    Fairbrother, D.B.; Lesniak, L.M.; Orgera, E.G.

    1977-10-01

    The report describes the reactor protection system (RPS-II) designed for use on Babcock and Wilcox 145-, later 177-, and 205-fuel assembly pressurized water reactors. In this system, relays in the trip logic have been replaced by solid state devices. A calculating module for the low DNBR, pump status, and offset trip functions has replaced the overpower trip (based on flow and imbalance), the power/RC pump trip, and the variable low-pressure trip. Included is a description of the changes from the present Oconee-type reactor protection system (RPS-I), a functional and hardware description of the calculating module, a description of the software programmed in the calculating module, and a discussion of the qualification program conducted to ensure that the degree of protection provided by RPS-II is not less than that provided by previously licensed systems supplied by B and W

  12. Smart Machine Protection System

    International Nuclear Information System (INIS)

    Clark, S.; Nelson, D.; Grillo, A.; Spencer, N.; Hutchinson, D.; Olsen, J.; Millsom, D.; White, G.; Gromme, T.; Allison, S.; Underwood, K.; Zelazny, M.; Kang, H.

    1991-11-01

    A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slow the repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerator to aid in the fault diagnostic process, and the protection system automatically restores the beams back to normal rates when the fault is diagnosed and corrected. The user interface includes facilities to monitor the performance of the system, and track rate limits, faults, and recoveries. There is an edit facility to define the devices to be included in the protection system, along with their set points, limits, and trip points. This set point and limit data is downloaded into the CAMAC modules, and the configuration data is compiled into a logical decision tree for the 68030 processor. 3 figs

  13. Smart machine protection system

    International Nuclear Information System (INIS)

    Clark, S.; Nelson, D.; Grillo, A.

    1992-01-01

    A Machine Protection System implemented on the SLC automatically controls the beam repetition rates in the accelerator so that radiation or temperature faults slow the repetition rate to bring the fault within tolerance without shutting down the machine. This process allows the accelerators to aid in the fault diagnostic process, and the protection system automatically restores the beams back to normal rates when the fault is diagnosed and corrected. The user interface includes facilities to monitor the performance of the system, and track rate limits, faults, and recoveries. There is an edit facility to define the devices to be included in the protection system, along with their set points, limits, and trip points. This set point and limit data is downloaded into the CAMAC modules, and the configuration data is complied into a logical decision tree for the 68030 processor. (author)

  14. Temporary physical protection systems

    International Nuclear Information System (INIS)

    Williams, J.D.; Gangel, D.J.; Madsen, R.W.

    1991-01-01

    Terrorism and other aspects of world political instability have created a high demand for temporary physical protection systems within the nuclear materials management community. They can be used when vehicles carrying important assets are away from their permanent fixed site location, around areas where experiments are being temporarily conducted, around construction areas and one portions of a fixed site physical security system which is temporarily inoperable. Physical security systems can be grouped into four categories: tactical, portable, semi-permanent, and fixed. The resources and experience gained at Sandia National Laboratories in over forty years of developing and implementing security systems for protecting nuclear weapons and fixed nuclear facilities is now being applied to temporary physical security systems. This paper emphasizes temporary physical security systems and their component parts that are presently available and identify additional system-subsystem objectives, requirements, and concepts

  15. Development of quench detection/protection system based on active power method for superconducting magnet by using capacitor circuit

    International Nuclear Information System (INIS)

    Nanato, N.; Otsuka, T.; Hesaka, S.; Murase, S.

    2013-01-01

    Highlights: ► The authors have presented an active power method for quench detection. ► A method for improving its characteristics using a capacitor circuit was proposed. ► Quench detection/protection test for a Bi2223 superconducting coil was carried out. ► The proposed method was more useful than the conventional one. -- Abstract: When a quench occurs in a superconducting magnet, excessive joule heating in normal region may damage the magnet. It is necessary to detect the quench as soon as possible and discharge magnetic energy stored in the magnet. The authors have presented a quench detection/protection system based on an active power method which detects the quench regardless of a self-inductive and mutual-inductive voltages and electromagnetic noise. In the conventional active power method, the inductive voltages are removed by cancel coils. In this paper, the authors propose a method to cancel an inductive voltage using a capacitor circuit. The quench detection/protection system becomes more precise and smaller than the conventional system through the capacitor circuit

  16. Digital integrated protection system

    International Nuclear Information System (INIS)

    Savornin, M.; Furet, M.

    1978-01-01

    As a result of technological progress it is now possible to achieve more elaborate protection functions able to follow more closely the phenomena to be supervised. For this reason the CEA, Framatome and Merlin/Gerin/CERCI have undertaken in commonn to develop a Digital Integrated Protection System (D.I.P.S.). This system is designed with the following aims: to improve the safety of the station, . to improve its availability, . to facilitate installation, . to facilitate tests and maintenance. The main characteristics adopted are: . possibilities of obtaining more elaborate monitoring and protection algorithm treatments, . order 4 redundancy of transducers, associated instruments and signal processing, . possibility of inhibiting part of the protection system, . standardisation of equipment, physical and electrical separation of redundant units, . use of multiplexed connections, . automation of tests. Four flow charts are presented: - DIPS with four APUP (Acquisition and Processing Unit for Protection) - APUP - LSU (Logic Safeguard Unit), number LSU corresponding to number fluidic safeguard circuits, - structure of a function unit, - main functions of the APUP [fr

  17. Sandia Laboratories plutonium protection system

    International Nuclear Information System (INIS)

    Bernard, E.A.; Miyoshi, D.S.; Gutierrez, F.D.

    1977-01-01

    Sandia Laboratories is developing an improved plutonium protection system (PPS) to demonstrate new concepts for enhancing special nuclear materials safeguards. PPS concepts include separation of functions, real-time item accountability and improved means for control of materials, activities and personnel access. Physical barriers and a secure communications network are designed into the system to offer greater protection against sabotage, diversion and theft attempts. Prototype systems are being constructed at Hanford, Washington and Albuquerque, New Mexico and will be subjected to a comprehensive testing and evaluation program

  18. NH4+ protects tomato plants against Pseudomonas syringae by activation of systemic acquired acclimation.

    Science.gov (United States)

    Fernández-Crespo, Emma; Scalschi, Loredana; Llorens, Eugenio; García-Agustín, Pilar; Camañes, Gemma

    2015-11-01

    NH4 (+) nutrition provokes mild toxicity by enhancing H2O2 accumulation, which acts as a signal activating systemic acquired acclimation (SAA). Until now, induced resistance mechanisms in response to an abiotic stimulus and related to SAA were only reported for exposure to a subsequent abiotic stress. Herein, the first evidence is provided that this acclimation to an abiotic stimulus induces resistance to later pathogen infection, since NH4 (+) nutrition (N-NH4 (+))-induced resistance (NH4 (+)-IR) against Pseudomonas syringae pv tomato DC3000 (Pst) in tomato plants was demonstrated. N-NH4 (+) plants displayed basal H2O2, abscisic acid (ABA), and putrescine (Put) accumulation. H2O2 accumulation acted as a signal to induce ABA-dependent signalling pathways required to prevent NH4 (+) toxicity. This acclimatory event provoked an increase in resistance against later pathogen infection. N-NH4 (+) plants displayed basal stomatal closure produced by H2O2 derived from enhanced CuAO and rboh1 activity that may reduce the entry of bacteria into the mesophyll, diminishing the disease symptoms as well as strongly inducing the oxidative burst upon Pst infection, favouring NH4 (+)-IR. Experiments with inhibitors of Put accumulation and the ABA-deficient mutant flacca demonstrated that Put and ABA downstream signalling pathways are required to complete NH4 (+)-IR. The metabolic profile revealed that infected N-NH4 (+) plants showed greater ferulic acid accumulation compared with control plants. Although classical salicylic acid (SA)-dependent responses against biotrophic pathogens were not found, the important role of Put in the resistance of tomato against Pst was demonstrated. Moreover, this work revealed the cross-talk between abiotic stress acclimation (NH4 (+) nutrition) and resistance to subsequent Pst infection. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  19. An overview of process instrumentation, protective safety interlocks and alarm system at the JET facilities active gas handling system

    International Nuclear Information System (INIS)

    Skinner, N.; Brennan, P.; Brown, K.; Gibbons, C.; Jones, G.; Knipe, S.; Manning, C.; Perevezentsev, A.; Stagg, R.; Thomas, R.; Yorkshades, J.

    2003-01-01

    The Joint European Torus (JET) Facilities Active Gas Handling System (AGHS) comprises ten interconnected processing sub-systems that supply, process and recover tritium from gases used in the JET Machine. Operations require a diverse range of process instrumentation to carry out a multiplicity of monitoring and control tasks and approximately 500 process variables are measured. The different types and application of process instruments are presented with specially adapted or custom-built versions highlighted. Forming part of the Safety Case for tritium operations, a dedicated hardwired interlock and alarm system provides an essential safety function. In the event of failure modes, each hardwired interlock will back-up software interlocks and shutdown areas of plant to a failsafe condition. Design of the interlock and alarm system is outlined and general methodology described. Practical experience gained during plant operations is summarised and the methods employed for routine functional testing of essential instrument systems explained

  20. Defense Acquisitions: Analysis of Processes Used to Evaluate Active Protection Systems

    National Research Council Canada - National Science Library

    Francis, Paul; Graveline, William R; Ahearn, Marie P; Breen, Beverly; Davis, Tana; Jenkins, Letisha; Patton, Kenneth E; Swierczek, Robert

    2007-01-01

    .... In 2005, the lead systems integrator for the Army's Future Combat Systems (FCS) program sought proposals for an APS developer and design and to deliver APS prototypes on vehicles by fiscal year 2009...

  1. Systems approach to tamper protection

    International Nuclear Information System (INIS)

    Myre, W.C.; Eaton, M.J.

    1980-01-01

    Tamper-protection is a fundamental requirement of effective containment and surveillance systems. Cost effective designs require that the tamper protection requirements be considered early in the design phase and at the system level. A discussion of tamper protection alternatives as well as an illustrative example system is presented

  2. The LHC quench protection system

    CERN Multimedia

    2009-01-01

    The new quench protection system (QPS) has the crucial roles of providing an early warning for any part of the superconducting coils and busbars that develop high resistance, as well as triggering the switch-off of the machine. Over 2000 new detectors will be installed around the LHC to make sure every busbar segment between magnets is monitored and protected. One of the major consolidation activities for the LHC is the addition of two new detectors to the quench protection system. A magnet quench occurs when part of the superconducting cable becomes normally-conducting. When the protection system detects an increased resistance the huge amount of energy stored in the magnet chains is safely extracted and ‘dumped’ into specially designed resistors. In the case of the main dipole chain, the stored energy in a single LHC sector is roughly the same as the kinetic energy of a passenger jet at cruising speed. The first new detector is designed to monitor the superconducting...

  3. Ablative thermal protection systems

    International Nuclear Information System (INIS)

    Vaniman, J.; Fisher, R.; Wojciechowski, C.; Dean, W.

    1983-01-01

    The procedures used to establish the TPS (thermal protection system) design of the SRB (solid rocket booster) element of the Space Shuttle vehicle are discussed. A final evaluation of the adequacy of this design will be made from data obtained from the first five Shuttle flights. Temperature sensors installed at selected locations on the SRB structure covered by the TPS give information as a function of time throughout the flight. Anomalies are to be investigated and computer design thermal models adjusted if required. In addition, the actual TPS ablator material loss is to be measured after each flight and compared with analytically determined losses. The analytical methods of predicting ablator performance are surveyed. 5 references

  4. Active and passive fire protection system in academic building KH. Mas Mansur, Islamic University of Indonesia

    Directory of Open Access Journals (Sweden)

    Suryoputro M. Ragil

    2018-01-01

    Full Text Available According to the theory of fire triangle, the existence of combustible materials, heat, and oxygen can cause fire disaster. KH. Mas Mansur building, Islamic University of Indonesia has a fire protection, but rarely to be checked regularly and the number of equipment is less standard as well as the lack of an evacuation route map to facilitate the evacuation process. Inside the building also does not provide safety signs such as the evacuation directions, exit, and warning in case of fire. Therefore, researchers analysed the infrastructure of prevention and control in the building KH. Mas Mansur. Researchers used the method of observation, interviews, and checklist to know the condition directly, and compare with the standard regulations. Results concordance rate of existing infrastructure is 67% fire extinguisher, hydrant box 56%, 71% alarms, sprinkler 0%, 40% detectors, emergency doors 71%, 50% emergency stairs, assembly point 0% and directions 0%. The current results were below the standard of at least 80%. As for recommendations, researchers create a new evacuation map then put the existing infrastructure according to standard regulations, and it had consulted with the specialist of Occupational Safety and Health in the field of fire.

  5. Involvement of endogenous antioxidant systems in the protective activity of pituitary adenylate cyclase-activating polypeptide against hydrogen peroxide-induced oxidative damages in cultured rat astrocytes.

    Science.gov (United States)

    Douiri, Salma; Bahdoudi, Seyma; Hamdi, Yosra; Cubì, Roger; Basille, Magali; Fournier, Alain; Vaudry, Hubert; Tonon, Marie-Christine; Amri, Mohamed; Vaudry, David; Masmoudi-Kouki, Olfa

    2016-06-01

    Astroglial cells possess an array of cellular defense mechanisms, including superoxide dismutase (SOD) and catalase antioxidant enzymes, to prevent damages caused by oxidative stress. Nevertheless, astroglial cell viability and functionality can be affected by significant oxidative stress. We have previously shown that pituitary adenylate cyclase-activating polypeptide (PACAP) is a potent glioprotective agent that prevents hydrogen peroxide (H2 O2 )-induced apoptosis in cultured astrocytes. The purpose of this study was to investigate the potential protective effect of PACAP against oxidative-generated alteration of astrocytic antioxidant systems. Incubation of cells with subnanomolar concentrations of PACAP inhibited H2 O2 -evoked reactive oxygen species accumulation, mitochondrial respiratory burst, and caspase-3 mRNA level increase. PACAP also stimulated SOD and catalase activities in a concentration-dependent manner, and counteracted the inhibitory effect of H2 O2 on the activity of these two antioxidant enzymes. The protective action of PACAP against H2 O2 -evoked inhibition of antioxidant systems in astrocytes was protein kinase A, PKC, and MAP-kinase dependent. In the presence of H2 O2 , the SOD blocker NaCN and the catalase inhibitor 3-aminotriazole, both suppressed the protective effects of PACAP on SOD and catalase activities, mitochondrial function, and cell survival. Taken together, these results indicate that the anti-apoptotic effect of PACAP on astroglial cells can account for the activation of endogenous antioxidant enzymes and reduction in respiration rate, thus preserving mitochondrial integrity and preventing caspase-3 expression provoked by oxidative stress. Considering its powerful anti-apoptotic and anti-oxidative properties, the PACAPergic signaling system should thus be considered for the development of new therapeutical approaches to cure various pathologies involving oxidative neurodegeneration. We propose the following cascade for the

  6. Adaptive protection algorithm and system

    Science.gov (United States)

    Hedrick, Paul [Pittsburgh, PA; Toms, Helen L [Irwin, PA; Miller, Roger M [Mars, PA

    2009-04-28

    An adaptive protection algorithm and system for protecting electrical distribution systems traces the flow of power through a distribution system, assigns a value (or rank) to each circuit breaker in the system and then determines the appropriate trip set points based on the assigned rank.

  7. The primary protection system software

    International Nuclear Information System (INIS)

    Tooley, P.A.

    1992-01-01

    This paper continues the detailed description of the Primary Protection System for Sizewell-B by providing an overview of design and implementation of the software, including the features of the design process which ensure that quality is delivered by the contractor. The Nuclear Electric software assessment activities are also described. The argument for the excellence of the software is made on the basis of a quality product delivered by the equipment supplier's design process, and the confirmation of this provided by the Nuclear Electric assessment process, which is as searching and complete an examination as is reasonably practicable to achieve. (author)

  8. Distribution system protection with communication technologies

    DEFF Research Database (Denmark)

    Wei, Mu; Chen, Zhe

    2010-01-01

    Due to the communication technologies’ involvement in the distribution power system, the time-critical protection function may be implemented more accurately, therefore distribution power systems’ stability, reliability and security could be improved. This paper presents an active distribution...

  9. Advanced physical protection systems for nuclear materials

    International Nuclear Information System (INIS)

    Jones, O.E.

    1975-10-01

    Because of the increasing incidence of terrorism, there is growing concern that nuclear materials and facilities need improved physical protection against theft, diversion, or sabotage. Physical protection systems for facilities or transportation which have balanced effectiveness include information systems, access denial systems, adequate and timely response, recovery capability, and use denial methods for despoiling special nuclear materials (SNM). The role of these elements in reducing societal risk is described; however, it is noted that, similar to nuclear war, the absolute risks of nuclear theft and sabotage are basically unquantifiable. Sandia Laboratories has a major Energy Research and Development Administration (ERDA) role in developing advanced physical protection systems for improving the security of both SNM and facilities. These activities are surveyed. A computer simulation model is being developed to assess the cost-effectiveness of alternative physical protection systems under various levels of threat. Improved physical protection equipment such as perimeter and interior alarms, secure portals, and fixed and remotely-activated barriers is being developed and tested. In addition, complete prototype protection systems are being developed for representative nuclear facilities. An example is shown for a plutonium storage vault. The ERDA safe-secure transportation system for highway shipments of all significant quantities of government-owned SNM is described. Adversary simulation as a tool for testing and evaluating physical protection systems is discussed. A list of measures is given for assessing overall physical protection system performance. (auth)

  10. Advanced physical protection systems for nuclear materials

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Because of the increasing incidence of terrorism, there is growing concern that nuclear materials and facilities need improved physical protection against theft, diversion, or sabotage. Physical protection systems for facilities or transportation which have balanced effectiveness include information systems, access denial systems, adequate and timely response, recovery capability, and use denial methods for despoiling special nuclear materials (SNM). The role of these elements in reducing societal risk is described; however, it is noted that, similar to nuclear war, the absolute risks of nuclear theft and sabotage are basically unquantifiable. Sandia Laboratories has a major US Energy Research and Development Administration (ERDA) role in developing advanced physical protection systems for improving the security of both SNM and facilities. These activities are surveyed in this paper. A computer simulation model is being developed to assess the cost-effectiveness of alternative physical protection systems under various levels of threat. Improved physical protection equipment such as perimeter and interior alarms, secure portals, and fixed and remotely activated barriers is being developed and tested. In addition, complete prototype protection systems are being developed for representative nuclear facilities. An example is shown for a plutonium storage vault. The ERDA safe-secure transportation system for highway shipments of all significant quantities of government-owned SNM is described. Adversary simulation as a tool for testing and evaluating physical protection systems is discussed. Finally, a list of measures is given for assessing overall physical protection system performance. (author)

  11. Protection of industrial power systems

    CERN Document Server

    DAVIES, T

    2006-01-01

    The protection which is installed on an industrial power system is likely to be subjected to more difficult conditions than the protection on any other kind of power system. Starting with the many simple devices which are employed and covering the whole area of industrial power system protection, this book aims to help achieve a thorough understanding of the protection necessary.Vital aspects such as the modern cartridge fuse, types of relays, and the role of the current transformer are covered and the widely used inverse definite-minimum time overcurrent relay, the theory of the M

  12. Hazards in the Solar System: Out-of-School Time Student Activities Focused on Engineering Protective Space Gloves

    Science.gov (United States)

    Vaughan, R. G.; Meyer, N.; Anderson, R. B.; Sokol, K.; Nolan, B.; Edgar, L. A.; Gaither, T. A.; Milazzo, M. P.; Clark, J.

    2017-12-01

    "In Good Hands: Engineering Space Gloves" is a new Engineering Adventures® curriculum unit created for students in grades 3-5 in out-of-school time programs. It was designed and created by the Engineering is Elementary® team at the Museum of Science in Boston, MA, in collaboration with subject matter experts at the USGS Astrogeology Science Center and teacher professional development experts at Northern Arizona University's Center for Science Teaching and Learning. As part of the NASA-funded PLANETS (Planetary Learning that Advances the Nexus of Engineering, Technology, and Science) project, the goals for this unit are to introduce students to some of the potential hazards that would be faced by astronauts exploring planetary bodies in the solar system, and to engage students in thinking about how to engineer solutions to these challenges. Potential human health hazards in planetary exploration include: little to no breathable oxygen, exposure to extreme temperatures and pressures, radiation, dusty or toxic environments, and/or high velocity debris. First, students experiment with gloves made of different materials to accomplish tasks like picking up paper clips, entering numbers on a calculator, and using simple tools, while also testing for insulating properties, protection from crushing forces, and resistance to dust contamination. Students explore the trade-offs between form and multiple desired functions, and gain an introduction to materials engineering. Students are then presented with three different missions. Mission 1 is to collect and return a sample from Saturn's moon, Titan; Mission 2 is mining asteroids for useful minerals; and Mission 3 is to build a radio tower on the far side of Earth's moon. Each of these missions exhibits different potential hazards. Based on their previous experiments with different types of glove materials, students develop and test glove designs that will protect astronauts from mission-specific hazards, while still

  13. SMART core protection system design

    International Nuclear Information System (INIS)

    Lee, J. K.; Park, H. Y.; Koo, I. S.; Park, H. S.; Kim, J. S.; Son, C. H.

    2003-01-01

    SMART COre Protection System(SCOPS) is designed with real-tims Digital Signal Processor(DSP) board and Network Interface Card(NIC) board. SCOPS has a Control Rod POSition (CRPOS) software module while Core Protection Calculator System(CPCS) consists of Core Protection Calculators(CPCs) and Control Element Assembly(CEA) Calculators(CEACs) in the commercial nuclear plant. It's not necessary to have a independent cabinets for SCOPS because SCOPS is physically very small. Then SCOPS is designed to share the cabinets with Plant Protection System(PPS) of SMART. Therefor it's very easy to maintain the system because CRPOS module is used instead of the computer with operating system

  14. Distributed Supervisory Protection Interlock System

    International Nuclear Information System (INIS)

    Walz, H.V.; Agostini, R.C.; Barker, L.; Cherkassky, R.; Constant, T.; Matheson, R.

    1989-03-01

    The Distributed Supervisory Protection Interlock System, DSPI, is under development at the Stanford Linear Accelerator Center for requirements in the areas of personnel protection, beam containment and equipment protection interlocks. The DSPI system, distributed over the application site, consists of segments with microprocessor-based controller and I/O modules, local area networks for communication, and a global supervisor computer. Segments are implemented with commercially available controller and I/O modules arranged in local interlock clusters, and associated software. Segments provide local interlock data acquisition, processing and control. Local area networks provide the communication backbone between segments and a global supervisor processor. The supervisor processor monitors the overall system, reports detail status and provides human interfaces. Details of an R and D test system, which will implement the requirements for personnel protection of 4 typical linear accelerator sectors, will be described. 4 refs., 2 figs

  15. Extravehicular Activity and Planetary Protection

    Science.gov (United States)

    Buffington, J. A.; Mary, N. A.

    2015-01-01

    The first human mission to Mars will be the farthest distance that humans have traveled from Earth and the first human boots on Martian soil in the Exploration EVA Suit. The primary functions of the Exploration EVA Suit are to provide a habitable, anthropometric, pressurized environment for up to eight hours that allows crewmembers to perform autonomous and robotically assisted extravehicular exploration, science/research, construction, servicing, and repair operations on the exterior of the vehicle, in hazardous external conditions of the Mars local environment. The Exploration EVA Suit has the capability to structurally interface with exploration vehicles via next generation ingress/egress systems. Operational concepts and requirements are dependent on the mission profile, surface assets, and the Mars environment. This paper will discuss the effects and dependencies of the EVA system design with the local Mars environment and Planetary Protection. Of the three study areas listed for the workshop, EVA identifies most strongly with technology and operations for contamination control.

  16. Distributed radiation protection console system

    International Nuclear Information System (INIS)

    Chhokra, R.S.; Deshpande, V.K.; Mishra, H.; Rajeev, K.P.; Thakur, Bipla B.; Munj, Niket

    2004-01-01

    Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the radiation status of the area either from the CRPC or will get to know the same directly from the installed only after entering the area. This shortcoming can lead to avoidable delays in attending to the work or to unwanted exposure. The authors have designed and developed a system called Distributed Radiation Protection Console (DRPC) to overcome this shortcoming. A DRPC is a console which is located outside the entrance of a given area and displays the radiation status of the area. It presents to health physicist and the plant operators a graphic over-view of the radiation and air activity levels in the particular area of the plant. It also provides audio visual annunciation of the alarm status. Each radioactive area in a nuclear facility will have its own DRPC, which will receive as its inputs the analog and digital signals from radiation monitoring instruments installed in the area and would not only show those readings on its video graphic screen but will also provide warning messages and instructions to the personnel entering the active areas. The various DRPCs can be integrated into a Local Area Network, where the

  17. Power system protection 3 application

    CERN Document Server

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  18. Management information system on radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela, E-mail: pabloag@cdtn.b, E-mail: lss@cdtn.b, E-mail: gmf@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  19. Management information system on radiation protection

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela

    2011-01-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  20. Reactor protection system. Revision 1

    International Nuclear Information System (INIS)

    Fairbrother, D.B.; Vincent, D.R.; Lesniak, L.M.

    1975-04-01

    The reactor protection system-II (RPS-II) designed for use on Babcock and Wilcox 145- and 205-fuel assembly pressurized water reactors is described. In this system, relays in the trip logic have been replaced by solid state devices. A calculating module for the low DNBR, pump status, and offset trip functions has replaced the overpower trip (based on flow and imbalance), the power/RC pump trip, and the variable low pressure trip. Included is a description of the changes from the present Oconee-type reactor protection system (RPS-I), a functional and hardware description of the calculating module, and a discussion of the qualification program conducted to ensure that the degree of protection provided by RPS-II is not less than that provided by previously licensed systems supplied by B and W. (U.S.)

  1. Modern thyratron crowbar protection systems

    International Nuclear Information System (INIS)

    Judd, D.A.; Kettle, L.J.; Menown, H.; Newton, B.P.; Nicholls, N.S.; Sheldrake, R.

    1992-01-01

    Two thyratron crowbar systems for high-power klystrons used in linear accelerators are described. The first, contained in an oil filled tank, is a complete system to protect a klystron powered from a 100-kV, 20-A d.c. supply. In the second system a CX1722 glass thyratron, operating in air, has been retrofitted to a test equipment, in place of a spark gap, to protect an Inductive Output Tube (IOT). An important parameter in the choice of the crowbar thyratron is the total coulombs to be switched. Measurements of these follow-on currents are presented. (R.P.) 4 refs.; 10 figs

  2. The APS machine protection system (MPS)

    International Nuclear Information System (INIS)

    Fuja, R.; Berg, B.; Arnold, N.

    1996-01-01

    The machine protection system (MPS) that protects the APS storage ring vacuum chamber from x-ray beams, is active. There are over 650 sensors monitored and networked through the MPS system. About the same number of other process variables are monitored by the much slower EPICS control system, which also has an input to the rf abort chain. The MPS network is still growing with the beam position limits detection system coming on-line. The network configuration, along with a limited description of individual subsystems, is presented

  3. The APS machine protection system (MPS)

    Energy Technology Data Exchange (ETDEWEB)

    Fuja, R.; Berg, B.; Arnold, N. [and others

    1996-08-01

    The machine protection system (MPS) that protects the APS storage ring vacuum chamber from x-ray beams, is active. There are over 650 sensors monitored and networked through the MPS system. About the same number of other process variables are monitored by the much slower EPICS control system, which also has an input to the rf abort chain. The MPS network is still growing with the beam position limits detection system coming on-line. The network configuration, along with a limited description of individual subsystems, is presented.

  4. Standpipe systems for fire protection

    CERN Document Server

    Isman, Kenneth E

    2017-01-01

    This important new manual goes beyond the published NFPA standards on installation of standpipe systems to include the rules in the International Building Code, municipal fire codes, the National Fire Code of Canada, and information on inspection, testing, and maintenance of standpipe systems. Also covered are the interactions between standpipe and sprinkler systems, since these important fire protection systems are so frequently installed together. Illustrated with design examples and practical applications to reinforce the learning experience, this is the go-to reference for engineers, architects, design technicians, building inspectors, fire inspectors, and anyone that inspects, tests or maintains fire protection systems. Fire marshals and plan review authorities that have the responsibility for reviewing and accepting plans and hydraulic calculations for standpipe systems are also an important audience, as are firefighters who actually use standpipe systems. As a member of the committees responsible for s...

  5. The Diamond machine protection system

    International Nuclear Information System (INIS)

    Heron, M.T.; Lay, S.; Chernousko, Y.; Hamadyk, P.; Rotolo, N.

    2012-01-01

    The Diamond Light Source Machine Protection System (MPS) manages the hazards from high power photon beams and other hazards to ensure equipment protection on the booster synchrotron and storage ring. The system has a shutdown requirement, on a beam mis-steer of under 1 msec and has to manage in excess of a thousand interlocks. This is realised using a combination of bespoke hardware and programmable logic controllers. The MPS monitors a large number of interlock signals from diagnostics instrumentation, vacuum instrumentation, photon front ends and plant monitoring subsystems. Based on logic it can then remove the source of the energy to ensure protection of equipment. Depending on requirements, interlocks are managed on a Local or a Global basis. The Global system is structured as two layers, and supports fast- and slow-response-time interlock requirements. A Global MPS module takes the interlock permits for a given interlock circuit from each of the cells of the accelerator, and, subject to all interlocks being good, produces a permit to operate the source of energy: the RF amplifier for vessel protection and the PSU for magnet protection. The Local MPS module takes fast Interlock inputs from one cell of the Storage Ring or one quadrant of the Booster. Fast interlocks are those that must drop the beam in under 400 μsec (the maximum speed of the interlock) in the event of failure. EPIC provides the user interface to the MPS system

  6. System Protection Schemes in Eastern Denmark

    DEFF Research Database (Denmark)

    Rasmussen, Joana

    outages in the southern part of the 132-kV system introduce further stress in the power system, eventually leading to a voltage collapse. The local System Protection Scheme against voltage collapse is designed as a response-based scheme, which is dependent on local indication of reactive and active power...... effective measures, because they are associated with large reactive power losses in the transmission system. Ordered reduction of wind generation is considered an effective measure to maintain voltage stability in the system. Reactive power in the system is released due to tripping of a significant amount...... system. In that way, the power system capability could be extended beyond normal limits....

  7. Controls and Machine Protection Systems

    CERN Document Server

    Carrone, E.

    2016-01-01

    Machine protection, as part of accelerator control systems, can be managed with a 'functional safety' approach, which takes into account product life cycle, processes, quality, industrial standards and cybersafety. This paper will discuss strategies to manage such complexity and the related risks, with particular attention to fail-safe design and safety integrity levels, software and hardware standards, testing, and verification philosophy. It will also discuss an implementation of a machine protection system at the SLAC National Accelerator Laboratory's Linac Coherent Light Source (LCLS).

  8. Explosive Ordnance Disposal (EOD) Ensembles: Biophysical Characteristics and Predicted Work Times With and Without Chemical Protection and Active Cooling Systems

    Science.gov (United States)

    2015-04-29

    Integrated groin protector (IGP), and Boot Protector); GORE lined leather combat boots; and NOMEX® gloves with Velcro ; and EOD9 full face helmet... effective heat removal or cooling capacity of the active cooling system could not be obtained on the manikin, reasonable estimates can be used to...Price MJ, & Oldroyd M. The effect of heat acclimation on thermal strain during explosives ordnance disposal (EOD) related activity in moderate and

  9. Power system protection 2 systems and methods

    CERN Document Server

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  10. Systemic administration of the apocarotenoid bixin protects skin against solar UV-induced damage through activation of NRF2.

    Science.gov (United States)

    Tao, Shasha; Park, Sophia L; Rojo de la Vega, Montserrat; Zhang, Donna D; Wondrak, Georg T

    2015-12-01

    Exposure to solar ultraviolet (UV) radiation is a causative factor in skin photodamage and carcinogenesis, and an urgent need exists for improved molecular photoprotective strategies different from (or synergistic with) photon absorption. Recent studies suggest a photoprotective role of cutaneous gene expression orchestrated by the transcription factor NRF2 (nuclear factor-E2-related factor 2). Here we have explored the molecular mechanism underlying carotenoid-based systemic skin photoprotection in SKH-1 mice and provide genetic evidence that photoprotection achieved by the FDA-approved apocarotenoid and food additive bixin depends on NRF2 activation. Bixin activates NRF2 through the critical Cys-151 sensor residue in KEAP1, orchestrating a broad cytoprotective response in cultured human keratinocytes as revealed by antioxidant gene expression array analysis. Following dose optimization studies for cutaneous NRF2 activation by systemic administration of bixin, feasibility of bixin-based suppression of acute cutaneous photodamage from solar UV exposure was investigated in Nrf2(+/+) versus Nrf2(-/-) SKH-1 mice. Systemic administration of bixin suppressed skin photodamage, attenuating epidermal oxidative DNA damage and inflammatory responses in Nrf2(+/+) but not in Nrf2(-/-) mice, confirming the NRF2-dependence of bixin-based cytoprotection. Taken together, these data demonstrate feasibility of achieving NRF2-dependent cutaneous photoprotection by systemic administration of the apocarotenoid bixin, a natural food additive consumed worldwide. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Trial operation of material protection, control, and accountability systems at two active nuclear material handling sites within the All-Russian Institute of Experimental Physics (VNIIEF)

    International Nuclear Information System (INIS)

    Skripka, G.; Vatulin, V.; Yuferev, V.

    1997-01-01

    This paper discusses Russian Federal Nuclear Center (RFNC)-VNIIEF activities in the area of nuclear material protection, control, and accounting (MPC and A) procedures enhancement. The goal of such activities is the development of an automated systems for MPC and A at two of the active VNIIEF research sites: a research (reactor) site and a nuclear material production facility. The activities for MPC and A system enhancement at both sites are performed in the framework of a VNIIEF-Los Alamos National Laboratory contract with participation from Sandia National Laboratories, Lawrence Livermore National Laboratory, Brookhaven National Laboratory, Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and PANTEX Plant in accordance with Russian programs supported by MinAtom. The American specialists took part in searching for possible improvement of technical solutions, ordering equipment, and delivering and testing the equipment that was provided by the Americans

  12. The protection system to Brazilian Nuclear Program

    International Nuclear Information System (INIS)

    Andreuzza, Mario Giussepp Santezzi Bertottelli

    1997-01-01

    The Sistema de Protecao ao Programa Nuclear Brasileiro-SIPRON (Protection System to Brazilian Nuclear Program) was established in 1980. It is intended to accomplish in only one system, all the actions related to security and protection for Nuclear Facilities in Brazil. The author presents in detail the protection system SIPRON, describing the system structure and organization, the functions and obligations of the system involved main organizations, as well as, the system operation and behaviour during an postulated occurrence of a nuclear emergency. It is also described an Exercise that happened in June of 1997 at the Nuclear Power Plant (NPP) Angra I, after two simulated tests in December of 1996 and April of 1997. The NPP Angra I Emergency Plan Exercise was a good opportunity to test the SIPRON structure and preparedness program. It was verified, included by International Atomic Energy Agency observers, the system involved organizations effectiveness and the procedures efficacy to protect the public and the environmental. Finally, it is shown the SIPRON activities of routine, the system obstacles and the expected future performances. (author)

  13. Assessment of physical protection systems: EVA method

    International Nuclear Information System (INIS)

    Bernard, J.-L.; Lamotte, C.; Jorda, A.

    2001-01-01

    CEA's missions in various sectors of activity such as nuclear, defence, industrial contracts and the associated regulatory requirements, make it necessary to develop a strategy in the field of physical protection. In particular, firms having nuclear materials are subject to the July 25, 1980 law no.80-572 on the protection and control of nuclear materials. A holding permit delivered by the regulatory authority is conditioned to the protection by the operator of the nuclear materials used. In France it is the nuclear operator who must demonstrate, in the form of a security study, that potential aggressors would be neutralised before they could escape with the material. To meet these requirements, we have developed methods to assess the vulnerability of our facilities. The EVA method, the French acronym for 'Evaluation de la vulnerabilite des Acces' (access vulnerability system) allows dealing with internal and external threats involving brutal actions. In scenarios relating to external threat, the intruders get past the various barriers of our protection system, attempting to steal a large volume of material in one swoop and then escape. In the case of internal threat, the goal is the same. However, as the intruder usually has access to the material in the scope of his activities, the action begins at the level of the target. Our protection system is based on in-depth defense where the intruders are detected and then delayed in their advance towards their target to allow time for intervention forces to intercept them

  14. RIVER PROTECTION PROJECT SYSTEM PLAN

    Energy Technology Data Exchange (ETDEWEB)

    CERTA PJ

    2008-07-10

    The U.S. Department of Energy (DOE), Office of River Protection (ORP) manages the River Protection Project (RPP). The RPP mission is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. As a result, the ORP is responsible for the retrieval, treatment, and disposal of the approximately 57 million gallons of radioactive waste contained in the Hanford Site waste tanks and closure of all the tanks and associated facilities. The previous revision of the System Plan was issued in September 2003. ORP has approved a number of changes to the tank waste treatment strategy and plans since the last revision of this document, and additional changes are under consideration. The ORP has established contracts to implement this strategy to establish a basic capability to complete the overall mission. The current strategy for completion of the mission uses a number of interrelated activities. The ORP will reduce risk to the environment posed by tank wastes by: (1) Retrieving the waste from the single-shell tanks (SST) to double-shell tanks (DST) for treatment and disposal; (2) Constructing and operating the WTP, which will safely treat all of the high-level waste (HLW) and about half of the low-activity waste (LAW) contained in the tank farms, and maximizing its capability and capacity; (3) Developing and deploying supplemental treatment capability or a second WTP LAW Facility that can safely treat about half of the LAW contained in the tank farms; (4) Developing and deploying treatment and packaging capability for transuranic (TRU) tank waste for shipment to and disposal at the Waste Isolation Pilot Plant (WIPP); (5) Deploying interim storage capacity for the immobilized HLW and shipping that waste to Yucca Mountain for disposal; (6) Operating the Integrated Disposal Facility for the disposal of immobilized LAW, along with the associated secondary waste, (7) Closing the SST and DST tank farms, ancillary facilities, and al1 waste

  15. RIVER PROTECTION PROJECT SYSTEM PLAN

    International Nuclear Information System (INIS)

    CERTA PJ

    2008-01-01

    The U.S. Department of Energy (DOE), Office of River Protection (ORP) manages the River Protection Project (RPP). The RPP mission is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. As a result, the ORP is responsible for the retrieval, treatment, and disposal of the approximately 57 million gallons of radioactive waste contained in the Hanford Site waste tanks and closure of all the tanks and associated facilities. The previous revision of the System Plan was issued in September 2003. ORP has approved a number of changes to the tank waste treatment strategy and plans since the last revision of this document, and additional changes are under consideration. The ORP has established contracts to implement this strategy to establish a basic capability to complete the overall mission. The current strategy for completion of the mission uses a number of interrelated activities. The ORP will reduce risk to the environment posed by tank wastes by: (1) Retrieving the waste from the single-shell tanks (SST) to double-shell tanks (DST) for treatment and disposal; (2) Constructing and operating the WTP, which will safely treat all of the high-level waste (HLW) and about half of the low-activity waste (LAW) contained in the tank farms, and maximizing its capability and capacity; (3) Developing and deploying supplemental treatment capability or a second WTP LAW Facility that can safely treat about half of the LAW contained in the tank farms; (4) Developing and deploying treatment and packaging capability for transuranic (TRU) tank waste for shipment to and disposal at the Waste Isolation Pilot Plant (WIPP); (5) Deploying interim storage capacity for the immobilized HLW and shipping that waste to Yucca Mountain for disposal; (6) Operating the Integrated Disposal Facility for the disposal of immobilized LAW, along with the associated secondary waste, (7) Closing the SST and DST tank farms, ancillary facilities, and al1 waste

  16. Radiation protection, 1975. Annual EPA review of radiation protection activities

    International Nuclear Information System (INIS)

    1976-06-01

    The EPA, under its Federal Guidance authorities, is responsible for advising the President on all matters pertaining to radiation and, through this mechanism, to provide guidance to other Federal agencies on radiation protection matters. Highlights are presented of significant radiation protection activities of all Federal agencies which were completed in 1975, or in which noteworthy progress was made during that period, and those events affecting members of the public. State or local activities are also presented where the effects of those events may be more far-reaching. At the Federal level significant strides have been made in reducing unnecessary radiation exposure through the efforts of the responsible agencies. These efforts have resulted in the promulgation of certain standards, criteria and guides. Improved control technologies in many areas make it feasible to reduce emissions at a reasonable cost to levels below current standards and guides. This report provides information on the significant activities leading to the establishment of the necessary controls for protection of public health and the environment. Radiation protection activities have been undertaken in other areas such as medical, occupational and consumer product radiation. In the context of radiation protection, ancillary activities are included in this report in order to present a comprehensive overview of the events that took place in 1975 that could have an effect on public health, either directly or indirectly. Reports of routine or continuing radiation protection operations may be found in publications of the sponsoring Federal agencies, as can more detailed information about activities reported in this document. A list of some of these reports is included

  17. Large thermal protection system panel

    Science.gov (United States)

    Weinberg, David J. (Inventor); Myers, Franklin K. (Inventor); Tran, Tu T. (Inventor)

    2003-01-01

    A protective panel for a reusable launch vehicle provides enhanced moisture protection, simplified maintenance, and increased temperature resistance. The protective panel includes an outer ceramic matrix composite (CMC) panel, and an insulative bag assembly coupled to the outer CMC panel for isolating the launch vehicle from elevated temperatures and moisture. A standoff attachment system attaches the outer CMC panel and the bag assembly to the primary structure of the launch vehicle. The insulative bag assembly includes a foil bag having a first opening shrink fitted to the outer CMC panel such that the first opening and the outer CMC panel form a water tight seal at temperatures below a desired temperature threshold. Fibrous insulation is contained within the foil bag for protecting the launch vehicle from elevated temperatures. The insulative bag assembly further includes a back panel coupled to a second opening of the foil bag such that the fibrous insulation is encapsulated by the back panel, the foil bag, and the outer CMC panel. The use of a CMC material for the outer panel in conjunction with the insulative bag assembly eliminates the need for waterproofing processes, and ultimately allows for more efficient reentry profiles.

  18. Early infections by myxoma virus of young rabbits (Oryctolagus cuniculus) protected by maternal antibodies activate their immune system and enhance herd immunity in wild populations.

    Science.gov (United States)

    Marchandeau, Stéphane; Pontier, Dominique; Guitton, Jean-Sébastien; Letty, Jérôme; Fouchet, David; Aubineau, Jacky; Berger, Francis; Léonard, Yves; Roobrouck, Alain; Gelfi, Jacqueline; Peralta, Brigitte; Bertagnoli, Stéphane

    2014-03-04

    The role of maternal antibodies is to protect newborns against acute early infection by pathogens. This can be achieved either by preventing any infection or by allowing attenuated infections associated with activation of the immune system, the two strategies being based on different cost/benefit ratios. We carried out an epidemiological survey of myxomatosis, which is a highly lethal infectious disease, in two distant wild populations of rabbits to describe the epidemiological pattern of the disease. Detection of specific IgM and IgG enabled us to describe the pattern of immunity. We show that maternal immunity attenuates early infection of juveniles and enables activation of their immune system. This mechanism associated with steady circulation of the myxoma virus in both populations, which induces frequent reinfections of immune rabbits, leads to the maintenance of high immunity levels within populations. Thus, myxomatosis has a low impact, with most infections being asymptomatic. This work shows that infection of young rabbits protected by maternal antibodies induces attenuated disease and activates their immune system. This may play a major role in reducing the impact of a highly lethal disease when ecological conditions enable permanent circulation of the pathogen.

  19. RIVER PROTECTION PROJECT SYSTEM PLAN

    International Nuclear Information System (INIS)

    Certa, P.J.; Kirkbride, R.A.; Hohl, T.M.; Empey, P.A.; Wells, M.N.

    2009-01-01

    The U.S. Department of Energy (DOE), Office of River Protection (ORP) manages the River Protection Project (RPP). The RPP mission is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. As a result, ORP is responsible for the retrieval, treatment, and disposal of approximately 57 million gallons 1 of radioactive waste contained in the Hanford Site waste tanks and closure2 of all the tanks and associated facilities. The previous revision of the System Plan was issued in May 2008. ORP has made a number of changes to the tank waste treatment strategy and plans since the last revision of this document, and additional changes are under consideration. ORP has contracts in place to implement the strategy for completion of the mission and establish the capability to complete the overall mission. The current strategl involves a number of interrelated activities. ORP will reduce risk to the environment posed by tank wastes by the following: (1) Retrieving the waste from the single-shell tanks (SST) to double-shell tanks (DST) and delivering the waste to the Waste Treatment and Immobilization Plant (WTP). (2) Constructing and operating the WTP, which will safely treat all of the high-level waste (HLW) fraction contained in the tank farms. About one-third of the low-activity waste (LAW) fraction separated from the HLW fraction in the WTP will be immobilized in the WTP LAW Vitrification Facility. (3) Developing and deploying supplemental treatment capability assumed to be a second LAW vitrification facility that can safely treat about two-thirds of the LAW contained in the tank farms. (4) Developing and deploying supplemental pretreatment capability currently assumed to be an Aluminum Removal Facility (ARF) using a lithium hydrotalcite process to mitigate sodium management issues. (5) Developing and deploying treatment and packaging capability for contact-handled transuranic (CH-TRU) tank waste for possible shipment to and disposal

  20. RIVER PROTECTION PROJECT SYSTEM PLAN

    Energy Technology Data Exchange (ETDEWEB)

    CERTA PJ; KIRKBRIDE RA; HOHL TM; EMPEY PA; WELLS MN

    2009-09-15

    The U.S. Department of Energy (DOE), Office of River Protection (ORP) manages the River Protection Project (RPP). The RPP mission is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. As a result, ORP is responsible for the retrieval, treatment, and disposal of approximately 57 million gallons 1 of radioactive waste contained in the Hanford Site waste tanks and closure2 of all the tanks and associated facilities. The previous revision of the System Plan was issued in May 2008. ORP has made a number of changes to the tank waste treatment strategy and plans since the last revision of this document, and additional changes are under consideration. ORP has contracts in place to implement the strategy for completion of the mission and establish the capability to complete the overall mission. The current strategl involves a number of interrelated activities. ORP will reduce risk to the environment posed by tank wastes by the following: (1) Retrieving the waste from the single-shell tanks (SST) to double-shell tanks (DST) and delivering the waste to the Waste Treatment and Immobilization Plant (WTP). (2) Constructing and operating the WTP, which will safely treat all of the high-level waste (HLW) fraction contained in the tank farms. About one-third of the low-activity waste (LAW) fraction separated from the HLW fraction in the WTP will be immobilized in the WTP LAW Vitrification Facility. (3) Developing and deploying supplemental treatment capability assumed to be a second LAW vitrification facility that can safely treat about two-thirds of the LAW contained in the tank farms. (4) Developing and deploying supplemental pretreatment capability currently assumed to be an Aluminum Removal Facility (ARF) using a lithium hydrotalcite process to mitigate sodium management issues. (5) Developing and deploying treatment and packaging capability for contact-handled transuranic (CH-TRU) tank waste for possible shipment to and

  1. Radiation protection activities and status in Asia

    International Nuclear Information System (INIS)

    Strohal, P.

    1993-01-01

    The status of radiation protection practices in Asian countries is monitored by different means, e.g. the IAEA technical cooperation activities, by an overall assessment of conditions in a country by RAPAT missions, and on the basis of data collected through various regional activities. The radiation protection situation in Asia is very heterogeneous. There is a group of countries with very well developed radiation protection practices and advanced in the application of the Basic Safety Standards, but the majority of Asian member states still need improvement, several lacking the necessary fundamental infrastructure for radiation protection

  2. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2005-11-01

    One of the main challenges facing radiological protection experts is how to integrate radiological protection within modern concepts of and approaches to risk governance. It is within this context that the International Commission on Radiological Protection (ICRP) decided to develop new general recommendations to replace its Publication 60 recommendations of 1990. In the process of developing these new recommendations, the views of the ICRP have evolved significantly, largely due to stakeholder involvement that has been actively solicited by the ICRP. In this regard, it was upheld during the First Asian Regional Conference organised by the NEA in October 2002 that the implementation of the new system must allow for regional, societal and cultural differences. In order to ensure appropriate consideration of these differences, the NEA organised the Second Asian Regional Conference on the Evolution of the System of Radiological Protection. Held in Tokyo on 28-29 July 2004, the conference included presentations by the ICRP Chair as well as by radiological experts from Australia, China, Japan and Korea. Within their specific cultural and socio-political milieu, Asia-Pacific and western ways of thought on how to improve the current system of radiological protection were presented and discussed. These ways of thinking, along with a summary of the conference results, are described in these proceedings. (author)

  3. ETHIOPIAN WITNESS PROTECTION SYSTEM: COMPARATIVE ...

    African Journals Online (AJOL)

    witness protection involves social cohesion of the protected person. Scholars ..... interests' need to balance an accused right to know and confront prosecution ..... was reduced to 2.5 years through the fast tracking of witness protection cases.

  4. Integrated nuclear and radiation protection systems

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, V.; Cerga, V.; Pirvu, V.; Badea, E.

    1993-01-01

    A multifunctional radiation monitoring equipment, flexible and capable to meet virtually environmental radiation monitoring, activity measurement and computational requirements, for nuclear laboratories has been designed. It can be used as a radiation protection system, for radionuclide measurement in isotope laboratories, nuclear technology, health physics and nuclear medicine, nuclear power stations and nuclear industry. The equipment is able to measure, transmit and record gamma dose rate and isotope activities. Other parameters and functions are optionally available, such as: self-contained alarm level, system self-test, dose integrator, syringe volume calculation for a given dose corrected for decay, calibration factor, 99 Mo assays performing and background subtraction

  5. Effects of pituitary adenylate cyclase activating polypeptide in the urinary system, with special emphasis on its protective effects in the kidney.

    Science.gov (United States)

    Reglodi, Dora; Kiss, Peter; Horvath, Gabriella; Lubics, Andrea; Laszlo, Eszter; Tamas, Andrea; Racz, Boglarka; Szakaly, Peter

    2012-04-01

    Pituitary adenylate cyclase activating polypeptide (PACAP) is a widespread neuropeptide with diverse effects in the nervous system and peripheral organs. One of the most well-studied effects of PACAP is its cytoprotective action, against different harmful stimuli in a wide variety of cells and tissues. PACAP occurs in the urinary system, from the kidney to the lower urinary tract. The present review focuses on the nephroprotective effects of PACAP and summarizes data obtained regarding the protective effects of PACAP in different models of kidney pathologies. In vitro data show that PACAP protects tubular cells against oxidative stress, myeloma light chain, cisplatin, cyclosporine-A and hypoxia. In vivo data provide evidence for its protective effects in ischemia/reperfusion, cisplatin, cyclosporine-A, myeloma kidney injury, diabetic nephropathy and gentamicin-induced kidney damage. Results accumulated on the renoprotective effects of PACAP suggest that PACAP is an emerging candidate for treatment of human kidney pathologies. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Passive and active protection of cotton textiles

    NARCIS (Netherlands)

    Bochove, C. van

    1967-01-01

    In rotproofing of cotton a distinction is made between passive and active protection. In passive protection, the structure of the cotton fibre is modified in such a way that the fibre can longer be attacked. This modification of structure can be effected on different levels: microscopical,

  7. System architecture for microprocessor based protection system

    International Nuclear Information System (INIS)

    Gallagher, J.M. Jr.; Lilly, G.M.

    1976-01-01

    This paper discusses the architectural design features to be employed by Westinghouse in the application of distributed digital processing techniques to the protection system. While the title of the paper makes specific reference to microprocessors, this is only one (and the newest) of the building blocks which constitutes a distributed digital processing system. The actual system structure (as realized through utilization of the various building blocks) is established through considerations of reliability, licensability, and cost. It is the intent of the paper to address these considerations licenstions as they relate to the architectural design features. (orig.) [de

  8. Activities of Moroccan Radiation Protection Association

    International Nuclear Information System (INIS)

    Choukri, A.

    2010-01-01

    Encourage activities and information exchange in the field of radiation protection and related areas; Assist in informing both the public and the professionals on the problems and requirements related to radiation protection for the protection of man and the environment; Promote professional training in radiation protection. The use of nuclear technology in medicine, agriculture and industry is very advanced in Morocco. This technological progress has been accompanied by fairly detailed legislation and significant involvement on the part of Morocco in international conventions and agreements

  9. Lightning Protection and Detection System

    Science.gov (United States)

    Dudley, Kenneth L. (Inventor); Szatkowski, George N. (Inventor); Woodard, Marie (Inventor); Nguyen, Truong X. (Inventor); Ely, Jay J. (Inventor); Wang, Chuantong (Inventor); Mielnik, John J. (Inventor); Koppen, Sandra V. (Inventor); Smith, Laura J. (Inventor)

    2017-01-01

    A lightning protection and detection system includes a non-conductive substrate material of an apparatus; a sensor formed of a conductive material and deposited on the non-conductive substrate material of the apparatus. The sensor includes a conductive trace formed in a continuous spiral winding starting at a first end at a center region of the sensor and ending at a second end at an outer corner region of the sensor, the first and second ends being open and unconnected. An electrical measurement system is in communication with the sensor and receives a resonant response from the sensor, to perform detection, in real-time, of lightning strike occurrences and damage therefrom to the sensor and the non-conductive substrate material.

  10. Regulatory System of Radiation Protection in Taiwan

    International Nuclear Information System (INIS)

    Tang, F. T.; Huang, C. C.

    2004-01-01

    After the radioactive contaminated buildings incident occurred in Taiwan in 1993, the competent authority for radiation protection the Atomic Energy Council (AEC) started to review the structured problem of radiation protection regulatory system. Through several years' investigation and study, the AEC has improved two important tools in radiation protection regulatory system, i.e., control regulations and actual practice, and made them more rigorous and efficient. This paper will make a brief introduction of the efforts that Taiwan has made in this respect. Taiwan's radiation protection control was based on the Atomic Energy Law promulgated in 1968, but the control idea and authorization scope were not sufficient to appropriately respond to the highly developed economy and democracy in Taiwan. After several years' legislative process, the Ionizing Radiation Protection Law (IRP Law) was promulgated and entered into force on February 1, 2003. This IRP Law specifically emphasizes categorized risk management of radiation sources, establishment of personnel licenses and training system, enhancement of public safety control, and implementation of quality assurance program for medical exposure. The Legislative Yuan (Congress) fully authorized the competent authority to establish various technological control regulations according to control necessity without prior review by the Legislative Yuan in advance. As to the penalties of the violations of the IRP Law, the AEC adopts high-rated administrative fines and applies the Criminal Law to those who seriously contaminate the environment. In actual practice, the AEC has constructed a Radiation Protection Control Information System compatible with the IRP Law that fully combines the functions of computers and Internet. The information of facility operators who own radiation sources, radiation protection specialists, and operating personnel are entered into this system, starting from the submission of application of the

  11. Wind turbine with lightning protection system

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a wind turbine comprising a lightning protection system comprising a waveguide interconnecting a communication device and a signal-carrying structure. In other aspects, the present invention relates to the use of a waveguide in a lightning protection system...... of a wind turbine, a power splitter and its use in a lightning protection system of a wind turbine....

  12. Automating occupational protection records systems

    International Nuclear Information System (INIS)

    Lyon, M.; Martin, J.B.

    1991-10-01

    Occupational protection records have traditionally been generated by field and laboratory personnel, assembled into files in the safety office, and eventually stored in a warehouse or other facility. Until recently, these records have been primarily paper copies, often handwritten. Sometimes, the paper is microfilmed for storage. However, electronic records are beginning to replace these traditional methods. The purpose of this paper is to provide guidance for making the transition to automated record keeping and retrieval using modern computer equipment. This paper describes the types of records most readily converted to electronic record keeping and a methodology for implementing an automated record system. The process of conversion is based on a requirements analysis to assess program needs and a high level of user involvement during the development. The importance of indexing the hard copy records for easy retrieval is also discussed. The concept of linkage between related records and its importance relative to reporting, research, and litigation will be addressed. 2 figs

  13. FPGA-Based Plant Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoon Hee; Ha, Jae Hong; Kim, Hang Bae [KEPCO E and C, Daejeon (Korea, Republic of)

    2011-08-15

    This paper relates to a plant protection system which detects non-permissible conditions and determines initiation of protective actions for nuclear power plants (NPPs). Conventional plant protection systems were designed based on analog technologies. It is well known that existing protection systems for NPPs contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance and repair for analog-based plant protection systems may be difficult as analog parts become obsolete or difficult to obtain. Accordingly, as an alternative to the analog technology, the digitalisation of the plant protection system was required. Recently digital plant protection systems which include programmable logic controllers (PLCs) and/or computers have been introduced. However PLC or computer-based plant protection systems use an operating system and application software, and so they may result in a common mode failure when a problem occurs in the operating system or application software. Field Programmable Gate Arrays (FPGAs) are highlighted as an alternative to conventional protection or control systems. The paper presents the design of a four-channel plant protection system whose protection functions are implemented in FPGAs without any central processing unit or operating system.

  14. FPGA-Based Plant Protection System

    International Nuclear Information System (INIS)

    Lee, Yoon Hee; Ha, Jae Hong; Kim, Hang Bae

    2011-01-01

    This paper relates to a plant protection system which detects non-permissible conditions and determines initiation of protective actions for nuclear power plants (NPPs). Conventional plant protection systems were designed based on analog technologies. It is well known that existing protection systems for NPPs contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance and repair for analog-based plant protection systems may be difficult as analog parts become obsolete or difficult to obtain. Accordingly, as an alternative to the analog technology, the digitalisation of the plant protection system was required. Recently digital plant protection systems which include programmable logic controllers (PLCs) and/or computers have been introduced. However PLC or computer-based plant protection systems use an operating system and application software, and so they may result in a common mode failure when a problem occurs in the operating system or application software. Field Programmable Gate Arrays (FPGAs) are highlighted as an alternative to conventional protection or control systems. The paper presents the design of a four-channel plant protection system whose protection functions are implemented in FPGAs without any central processing unit or operating system

  15. Deficiencies in radiation protection record systems

    International Nuclear Information System (INIS)

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system

  16. Deficiencies in radiation protection record systems

    International Nuclear Information System (INIS)

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system. 8 refs

  17. SNAP: a tool for nuclear physical protection system modeling

    International Nuclear Information System (INIS)

    Engi, D.; Grant, F.H. III.

    1979-10-01

    Nuclear safeguards systems are concerned, in part, with the physical protection of nuclear materials. The function of a physical protection system is to define the facility against adversary activities which could lead to theft of nuclear material or sabotage resulting in a radiological release. The Safeguards Network Analysis Procedure (SNAP) provides a convenient and standard analysis methodology for the evaluation of physical protection system analysis. This paper describes a detailed application of SNAP to a hypothetical nuclear facility

  18. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  19. Mission and activities of the International Commission on Radiological Protection

    International Nuclear Information System (INIS)

    Clements, C.H.

    2018-01-01

    The International Commission on Radiological Protection (ICRP), formed in 1928, develops the System of Radiological Protection for the public benefit. The objective of the recommendations is to contribute to an appropriate level of protection for people and the environment against the harmful effects of radiation exposure without unduly limiting the individual or societal benefits of activities involving radiation. In developing its recommendations, ICRP considers advances in scientific knowledge, evolving social values, and practical experience. These recommendations are the basis of radiological protection standards and practice worldwide

  20. Radiation protection activities around the CERN accelerators

    International Nuclear Information System (INIS)

    Fasso, A.

    1996-01-01

    In 1995 several operational circumstances required careful watching by the Radiation Protection Group. Most of these were linked with new or recently started CERN activities: for instance the increasing importance assumed by ISOLDE operation and the breakdowns encountered which have given rise to contamination of the target region and to activity releases. In the SPS ring, several difficulties were brought about by a toilsome installation of a new interlock system, while lead ion operation marked the end of the year, as usual, with higher radiation levels in the SPS experimental areas, despite the fact that existing shielding had been improved. Also at the end of the year, the increase of LEP beam energy to 68 GeV caused a rise of dose rate levels from synchrotron radiation. This was expected, but studies are still needed to assess the full implications for different aspects of radiation protection. On the other hand, the ageing of magnet coils and other equipment (insulators, cables, flexible pipes), aggravated by the high proton beam intensities, has resulted in an increasing frequency of failures (mainly water leaks) both at the PS and at the SPS. If the apparent trend is confirmed, difficulties could be expected in the future for two reasons: the shortage of specialized staff, some of them approaching the CERN dose limit of 15 mSv annually, who can be assigned to repair work; and the lack of spare parts to replace the damaged items. Luckily, the long cooling times following high intensity proton runs provided by the operation with heavy-ions and by the winter shutdown mitigate this situation

  1. Reactor protection system including engineered features actuation system

    International Nuclear Information System (INIS)

    Palmaers, W.

    1982-01-01

    The safety concept requires to ensure that - the reactor protection system - the active engineered safeguard - and the necessary auxiliary systems are so designed and interfaced in respect of design and mode of action that, in the event of single component failure reliable control of the consequences of accidents remains ensured at all times and that the availability of the power plant is not limited unnecessarily. In order to satisfy these requirements due, importance was attached to a consistent spacial separation of the mutually redundant subsystems of the active safety equipment. The design and layout of the reactor protection system, of the power supply (emergency power supply), and of the auxiliary systems important from the safety engineering point of view, are such that their subsystems also largely satisfy the requirements of independence and spacial separation. (orig./RW)

  2. European activities in radiation protection in medicine

    International Nuclear Information System (INIS)

    Simeonov, Georgi

    2015-01-01

    The recently published Council Directive 2013/59/Euratom ('new European Basic Safety Standards', EU BSS) modernises and consolidates the European radiation protection legislation by taking into account the latest scientific knowledge, technological progress and experience with implementing the current legislation and by merging five existing Directives into a single piece of legislation. The new European BSS repeal previous European legislation on which the national systems for radiation protection in medicine of the 28 European Union (EU) Member States are based, including the 96/29/Euratom 'BSS' and the 97/43/ Euratom 'Medical Exposure' Directives. While most of the elements of the previous legislation have been kept, there are several legal changes that will have important influence over the regulation and practice in the field all over Europe-these include, among others: (i) strengthening the implementation of the justification principle and expanding it to medically exposed asymptomatic individuals, (ii) more attention to interventional radiology, (iii) new requirements for dose recording and reporting, (iv) increased role of the medical physics expert in imaging, (v) new set of requirements for preventing and following up on accidents and (vi) new set of requirements for procedures where radiological equipment is used on people for non-medical purposes (nonmedical imaging exposure). The EU Member States have to enforce the new EU BSS before January 2018 and bring into force the laws, regulations and administrative provisions necessary to comply with it. The European Commission has certain legal obligations and powers to verify the compliance of the national measures with the EU laws and, wherever necessary, issue recommendations to, or open infringement cases against, national governments. In order to ensure timely and coordinated implementation of the new European legal requirements for radiation protection, the Commission is

  3. Identity management and witness protection system

    OpenAIRE

    Paunović, Saša; Starčević, Dušan; Nešić, Lazar

    2013-01-01

    The protection of participants in criminal proceedings is one of the most important tools for prosecution of war crimes and organized crime cases. The paper presents the basic characteristics and the importance of implementing the Program of protection in criminal proceedings, with emphasis on the protection system and management of identity. Special attention was paid to challenges facing the protection system in criminal proceedings and the management of identities, which are caused by the ...

  4. Reactor protection and shut-down system

    International Nuclear Information System (INIS)

    Klar

    1980-01-01

    The reactor protection system being a part of the reactor safety system. The requirements on the reactor protection system are: high safety with regard to signal processing, high availability, self-reporting of faults etc. The functional sections of the reactor protection system are the analog section, the logic section and the generating of output signals. Description of the operation characteristics and of the extension of function. (orig.)

  5. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-01-01

    The design of an effective physical protection system includes the determination of physical protection system objectives, initial design of a physical protection system, design evaluation, and probably a redesign or refinement. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the physical protection system, that is, open-quotes what to protect against whom.close quotes The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control elements, procedures, communication devices, and protective forces personnel to meet the objectives of the system. Once a physical protection system is designed, it must be analyzed and evaluated to ensure it meets the physical protection objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. This paper reviews the physical protection system design and methodology mentioned above. Examples of the steps required and a brief introduction to some of the technologies used in modem physical protections system are given

  6. LHC magnet quench protection system

    Science.gov (United States)

    Coull, L.; Hagedorn, D.; Remondino, V.; Rodriguez-Mateos, F.

    1994-07-01

    The quench protection system for the superconducting magnets of the CERN Large Hadron Collider (LHC) is described. The system is based on the so called 'cold diode' concept. In a group of series connected magnets if one magnet quenches then the magnetic energy of all the magnets will be dissipated in the quenched magnet so destroying it. This is avoided by by-passing the quenched magnet and then rapidly de-exciting the unquenched magnets. For the LHC machine it is foreseen to use silicon diodes situated inside the cryostat as by-pass elements - so called 'cold diodes'. The diodes are exposed to some 50 kGray of radiation during a 10 year operation life-time. The high energy density of the LHC magnets (500 kJ/m) coupled with the relatively slow propagation speed of a 'natural' quench (10 to 20 m/s) can lead to excessive heating of the zone where the quench started and to high internal voltages. It is therefore necessary to detect quickly the incipient quench and fire strip heaters which spread the quench out more quickly over a large volume of the magnet. After a quench the magnet chain must be de-excited rapidly to avoid spreading the quench to other magnets and over-heating the by-pass diode. This is done by switching high-power energy-dump resistors in series with the magnets. The LHC main ring magnet will be divided into 16 electrically separated units which has important advantages.

  7. LHC magnet quench protection system

    International Nuclear Information System (INIS)

    Coull, L.; Hagedorn, D.; Remondino, V.; Rodriguez-Mateos, F.

    1994-01-01

    The quench protection system for the superconducting magnets of the CERN Large Hadron Collider (LHC) is described. The system is based on the so called ''cold diode'' concept. In a group of series connected magnets if one magnet quenches then the magnetic energy of all the magnets will be dissipated in the quenched magnet so destroying it. This is avoided by by-passing the quenched magnet and then rapidly de-exciting the unquenched magnets. For the LHC machine it is foreseen to use silicon diodes situated inside the cryostat as by-pass elements--so called ''cold diodes''. The diodes are exposed to some 50 kGray of radiation during a 10 year operation life-time. The high energy density of the LHC magnets (500 kJ/m) coupled with the relatively slow propagation speed of a ''natural'' quench (10 to 20 m/s) can lead to excessive heating of the zone where the quench started and to high internal voltages. It is therefore necessary to detect quickly the incipient quench and fire strip heaters which spread the quench out more quickly over a large volume of the magnet. After a quench the magnet chain must be de-excited rapidly to avoid spreading the quench to other magnets and over-heating the by-pass diode. This is done by switching high-power energy-dump resistors in series with the magnets. The LHC main ring magnet will be divided into 16 electrically separated units which has important advantages

  8. National Ignition Facility environmental protection systems

    International Nuclear Information System (INIS)

    Mintz, J.M.; Reitz, T.C.; Tobin, M.T.

    1994-06-01

    The conceptual design of Environmental Protection Systems (EPS) for the National Ignition Facility (NIF) is described. These systems encompass tritium and activated debris handling, chamber, debris shield and general decontamination, neutron and gamma monitoring, and radioactive, hazardous and mixed waste handling. Key performance specifications met by EPS designs include limiting the tritium inventory to 300 Ci and total tritium release from NIF facilities to less than 10 Ci/yr. Total radiation doses attributable to NIF shall remain below 10 mrem/yr for any member of the general public and 500 mrem/yr for NIF staff. ALARA-based design features and operational procedures will, in most cases, result in much lower measured exposures. Waste minimization, improved cycle time and reduced exposures all result from the proposed CO2 robotic arm cleaning and decontamination system, while effective tritium control is achieved through a modern system design based on double containment and the proven detritiation technology

  9. Modulation of inflammasome-mediated pulmonary immune activation by type I IFNs protects bone marrow homeostasis during systemic responses to Pneumocystis lung infection.

    Science.gov (United States)

    Searles, Steve; Gauss, Katherine; Wilkison, Michelle; Hoyt, Teri R; Dobrinen, Erin; Meissner, Nicole

    2013-10-01

    Although acquired bone marrow failure (BMF) is considered a T cell-mediated autoimmune disease, possible innate immune defects as a cause for systemic immune deviations in response to otherwise innocuous infections have not been extensively explored. In this regard, we recently demonstrated an important role of type I IFNs in protecting hematopoiesis during systemic stress responses to the opportunistic fungal pathogen Pneumocystis in lymphocyte-deficient mice. Mice deficient in both lymphocytes and type I IFN receptor (IFrag(-/-) mice) develop rapidly progressing BMF due to accelerated bone marrow (BM) cell apoptosis associated with innate immune deviations in the BM in response to Pneumocystis lung infection. However, the communication pathway between lung and BM eliciting the induction of BMF in response to this strictly pulmonary infection has been unclear. In this study, we report that absence of an intact type I IFN system during Pneumocystis lung infection not only causes BMF in lymphocyte-deficient mice but also transient BM stress in lymphocyte-competent mice. This is associated with an exuberant systemic IFN-γ response. IFN-γ neutralization prevented Pneumocystis lung infection-induced BM depression in type I IFN receptor-deficient mice and prolonged neutrophil survival time in BM from IFrag(-/-) mice. IL-1β and upstream regulators of IFN-γ, IL-12, and IL-18 were also upregulated in lung and serum of IFrag(-/-) mice. In conjunction, there was exuberant inflammasome-mediated caspase-1 activation in pulmonary innate immune cells required for processing of IL-18 and IL-1β. Thus, absence of type I IFN signaling during Pneumocystis lung infection may result in deregulation of inflammasome-mediated pulmonary immune activation, causing systemic immune deviations triggering BMF in this model.

  10. Protective and Catching Safety Systems In Construction

    Directory of Open Access Journals (Sweden)

    Kuzhin Marat

    2017-01-01

    Full Text Available In the article is described application of protective and catching systems in construction. Classification of similar systems, their types and purpose are listed. Dangerous zones on construction site and events to for limiting their influence or protection from the factors. Protective and catching systems is one of the most effective technical equipment, applied in recent time. Protective fences and catching systems are important part in the problem solution. Protective fences protect workers from falling from height. Protective and catching systems allows avoid injuries by workers, also catch debris, fallen from constructing buildings. In regard with continuing development in technical and technological solutions, protective and catching systems require adaptation to a new requirements of construction industry and requirements of normative documents. Technical regulations in the appliance sphere of protective and catching systems requires actualization and aligning with modern normatives. Important role should be given to developing organizational and technological documentation for application of the systems. Scientific studying of technical parameters of fences and protective catching nets also has great interest.

  11. River Protection Project information systems assessment

    Energy Technology Data Exchange (ETDEWEB)

    JOHNSON, A.L.

    1999-07-28

    The Information Systems Assessment Report documents the results from assessing the Project Hanford Management Contract (PHMC) Hanford Data Integrator 2000 (HANDI 2000) system, Business Management System (BMS) and Work Management System phases (WMS), with respect to the System Engineering Capability Assessment Model (CAM). The assessment was performed in accordance with the expectations stated in the fiscal year (FY) 1999 Performance Agreement 7.1.1, item (2) which reads, ''Provide an assessment report on the selected Integrated Information System by July 31, 1999.'' This report assesses the BMS and WMS as implemented and planned for the River Protection Project (RPP). The systems implementation is being performed under the PHMC HANDI 2000 information system project. The project began in FY 1998 with the BMS, proceeded in FY 1999 with the Master Equipment List portion of the WMS, and will continue the WMS implementation as funding provides. This report constitutes an interim quality assessment providing information necessary for planning RPP's information systems activities. To avoid confusion, HANDI 2000 will be used when referring to the entire system, encompassing both the BMS and WMS. A graphical depiction of the system is shown in Figure 2-1 of this report.

  12. River Protection Project information systems assessment

    International Nuclear Information System (INIS)

    JOHNSON, A.L.

    1999-01-01

    The Information Systems Assessment Report documents the results from assessing the Project Hanford Management Contract (PHMC) Hanford Data Integrator 2000 (HANDI 2000) system, Business Management System (BMS) and Work Management System phases (WMS), with respect to the System Engineering Capability Assessment Model (CAM). The assessment was performed in accordance with the expectations stated in the fiscal year (FY) 1999 Performance Agreement 7.1.1, item (2) which reads, ''Provide an assessment report on the selected Integrated Information System by July 31, 1999.'' This report assesses the BMS and WMS as implemented and planned for the River Protection Project (RPP). The systems implementation is being performed under the PHMC HANDI 2000 information system project. The project began in FY 1998 with the BMS, proceeded in FY 1999 with the Master Equipment List portion of the WMS, and will continue the WMS implementation as funding provides. This report constitutes an interim quality assessment providing information necessary for planning RPP's information systems activities. To avoid confusion, HANDI 2000 will be used when referring to the entire system, encompassing both the BMS and WMS. A graphical depiction of the system is shown in Figure 2-1 of this report

  13. Reactor protection system refurbishment at Paks

    International Nuclear Information System (INIS)

    Hetzmann, A.; Turi, T.

    1997-01-01

    The history and the milestones of the reactor protection system refurbishment are outlined. During the preparation phase of the refurbishment project, detailed requirements have been set up and specific technical solutions developed. The structure of the project documents prepared during these activities is shown in a figure. The life cycle of the project was divided into four phases: the preparatory phase; the design and manufacturing phase; the installation and commissioning phase; and the operation phase. For all four Paks units a time schedule for implementation was set up. The licensing process is dealt with; the principal license was issued in June 1996. (A.K.)

  14. The information protection level assessment system implementation

    Science.gov (United States)

    Trapeznikov, E. V.

    2018-04-01

    Currently, the threat of various attacks increases significantly as automated systems become more widespread. On the basis of the conducted analysis the information protection level assessment system establishing objective was identified. The paper presents the information protection level assessment software implementation in the information system by applying the programming language C #. In conclusions the software features are identified and experimental results are represented.

  15. Regulatory control of physical protection systems

    International Nuclear Information System (INIS)

    Rajdeep; Mayya, Y.S.

    2017-01-01

    The safety of facilities in BARC is under the regulatory oversight of BSC. The security architecture for these facilities incorporates multiple layers of Physical Protection Systems. The demands of safety may sometimes conflict with the needs of security. Realizing the need to identify these interfaces and extend the regulatory coverage to Physical Protection Systems, a Standing Committee named Physical Protection System Review Committee (PPSRC) has been constituted as a 2"n"d tier entity of BSC. PPSRC includes experts from various domains concerned with nuclear security, viz. physical protection systems, cyber security, radiation safety, security operations, technical services and security administration

  16. Design Of Photovoltaic Powered Cathodic Protection System

    Directory of Open Access Journals (Sweden)

    Golina Samir Adly

    2017-07-01

    Full Text Available The corrosion caused by chemical reaction between metallic structures and surrounding mediums such as soil or water .the CP cathodic protection system is used to protect metallic structure against corrosion. Cathodic protection CP used to minimize corrosion by utilizing an external source of electrical current which forces the entire structure to become a cathode. There are two Types of cathodic protection system Galvanic current Impressed current.the Galvanic current is called a sacrificial anode is connected to the protected structure cathode through a DC power supply. In Galvanic current system a current passes from the sacrificing anode to the protected structure .the sacrificial anode is corroded rather than causing the protected structure corrosion .protected structure requires a constant current to stop the corrosion which determined by area structure metal and the surrounding medium. The rains humidity are decrease soil resistivity and increase the DC current .The corrosion and over protection resulting from increase in the DC current is harmful for the metallic structure. This problem can be solved by conventional cathodic protection system by manual adjustment of DC voltage periodically to obtain a constant current .the manual adjustment of DC voltage depends on experience of the technician and using the accuracy of the measuring equipment. The errors of measuring current depend on error from the technician or error from the measuring equipment. the corrosion of structure may occur when the interval between two successive adjustment is long .An automatically regulated cathodic protection system is used to overcome problems from conventional cathodic protection system .the regulated cathodic protection system adjust the DC voltage of the system automatically when it senses the variations of surrounding medium resistivity so the DC current is constant at the required level.

  17. Programmed system for nuclear power plant protection

    International Nuclear Information System (INIS)

    Jover, Pierre.

    1980-06-01

    The progress in the field of microprocessors and large scale integration circuits, have incited to introduce this new technologies into nuclear power plant protection system. The hardware and software design principles are briefly listed; then, a quad-redundant protection system for 1300 MWe PWR, developed in France is described [fr

  18. Availability analysis of supervised protective systems

    International Nuclear Information System (INIS)

    Kontoleon, N.; Kontoleon, J.M.; Chrysochoides, N.G.

    1975-01-01

    The behaviour in time of a nuclear reactor supervised protective system is modelled mathematically by a Markov process, continuous in time and with three discrete states. Failure and repair rates are assumed to be exponentially distributed. An analytical expression of system availability as a function of failure and repair rates as well as the inspection intervals and duration is derived. An optimization problem is then discussed in order to maximize system availability with respect to imposed cost constraints. Finally, an example of a supervised protective system with short inactive times is given, which may be found in many practical situations of modern protective systems. (author)

  19. Centralized Coordination of Load Shedding & Protection System of Transmission Lines

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Bak, Claus Leth

    2018-01-01

    The power system integrity is vulnerable to thermal limit of transmission lines due to overloading and consequently activation of their protection devices following severe contingencies. In this paper, the loading rate of transmission lines is monitored online and is considered in the centralized......, over current protection....

  20. An integrated system for physical protection

    International Nuclear Information System (INIS)

    Kumar, Ranajit

    2001-01-01

    An Integrated Physical Protection System (IPPS) was developed for the consolidation of all sub systems, sensors and elements related to physical protection for an efficient and effective security environment of a facility. An effective physical protection system discharges the functions of detection, delay, communication, response, access control etc. IPPS performs, controls and monitors all the above functionality and helps in taking quick action on occurrence of unusual incidents by instantly reporting the incident in easily understandable audio, video, graphical and textual format and also by initiating automatic interactions among sub-systems

  1. Outer skin protection of columbium Thermal Protection System (TPS) panels

    Science.gov (United States)

    Culp, J. D.

    1973-01-01

    A coated columbium alloy material system 0.04 centimeter thick was developed which provides for increased reliability to the load bearing character of the system in the event of physical damage to and loss of the exterior protective coating. The increased reliability to the load bearing columbium alloy (FS-85) was achieved by interposing an oxidation resistant columbium alloy (B-1) between the FS-85 alloy and a fused slurry silicide coating. The B-1 alloy was applied as a cladding to the FS-85 and the composite was fused slurry silicide coated. Results of material evaluation testing included cyclic oxidation testing of specimens with intentional coating defects, tensile testing of several material combinations exposed to reentry profile conditions, and emittance testing after cycling of up to 100 simulated reentries. The clad material, which was shown to provide greater reliability than unclad materials, holds significant promise for use in the thermal protection system of hypersonic reentry vehicles.

  2. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  3. Protecting patients’ electronic health records using enhanced active bundles

    NARCIS (Netherlands)

    Salih, R.M.; Lilien, L.T.; Ben Othmane, L.; Arriaga, R.; Matic, A.

    2012-01-01

    We propose a solution that provides protection for patients' electronic health/medical records disseminated among different authorized healthcare information systems. The solution is known as Active Bundles using a Trusted Third Party (ABTTP). It is based on the use of trusted third parties, and the

  4. Testing Digital Electronic Protection Systems

    CERN Document Server

    Gabourin, S

    2011-01-01

    This paper outlines the core concepts and realisation of the Safe Machine Parameters Controller (SMPC) testbench, based on a VME crate and LabVIEW program. Its main goal is to ensure the correct function of the SMPC for the protection of the CERN accelerator complex. To achieve this, the tester has been built to replicate the machine environment and operation, in order to ensure that the chassis under test is completely exercised. The complexity of the task increases with the number of input combinations. This paper also outlines the benefits and weaknesses of developing a test suite independently of the hardware being tested, using the “V” approach.

  5. Integrated crop protection as a system approach

    OpenAIRE

    Haan, de, J.J.; Wijnands, F.G.; Sukkel, W.

    2005-01-01

    New farming systems in vegetable production are required as demands for high quality products that do not pollute the environment are rising, and production risks are large and incomes low. The methodology of prototyping new systems is described, especially the themes, parameters and target values connected to integrated crop protection. The role of integrated crop protection in prototyping new systems is discussed. The results of twenty years working with this prototyping methodology are pre...

  6. A protection system for picosecond accelerator

    International Nuclear Information System (INIS)

    Cao Hongping; Chinese Academy of Sciences, Beijing; Chen Huanguang; Xu Ruinian; Tang Junlong; Li Deming

    2006-01-01

    A personnel and machine protection system for the picosecond accelerator has been built. The key of the system is to send on/off of three triggering signals which are those of electron gun, 2856 MHz and 476 MHz, respectively, to ensure the safety of users and the accelerator. This paper describes the emergencies interlocked by ADAM5511 and timing trigger processor, and some secondary functions which improve the efficiency of the protection system completed in upper layer software. (authors)

  7. Explosion-protected electric heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Elsner, H

    1984-02-01

    Different constructions of explosion-protected heating systems are described concerning the different types of protection, the service conditions, the installation and the surveillance devices. Interpretations and regulations derived from the VDE Standards are discussed and their relation to the European Standards EN 50014 ... 50020 is considered in a survey.

  8. Microsoft System Center Data Protection Manager 2012

    CERN Document Server

    Buchannan, Steve; Gomaa, Islam

    2013-01-01

    This book is a Packt tutorial, walking the administrator through the steps needed to create real solutions to the problems and tasks faced when ensuring that their data is protected. This book is for network administrators, system administrators, backup administrators, or IT consultants who are looking to expand their knowledge on how to utilize DPM to protect their organization's data.

  9. Analog subsystem for the plutonium protection system

    International Nuclear Information System (INIS)

    Arlowe, H.D.

    1978-12-01

    An analog subsystem is described which monitors certain functions in the Plutonium Protection System. Rotary and linear potentiometer output signals are digitized, as are the outputs from thermistors and container ''bulge'' sensors. This work was sponsored by the Department of Energy/Office of Safeguards and Security (DOE/OSS) as part of the overall Sandia Fixed Facility Physical Protection Program

  10. Systems and methods for photovoltaic string protection

    Science.gov (United States)

    Krein, Philip T.; Kim, Katherine A.; Pilawa-Podgurski, Robert C. N.

    2017-10-25

    A system and method includes a circuit for protecting a photovoltaic string. A bypass switch connects in parallel to the photovoltaic string and a hot spot protection switch connects in series with the photovoltaic string. A first control signal controls opening and closing of the bypass switch and a second control signal controls opening and closing of the hot spot protection switch. Upon detection of a hot spot condition the first control signal closes the bypass switch and after the bypass switch is closed the second control signal opens the hot spot protection switch.

  11. Relay protection coordination with generator capability curve, excitation system limiters and power system relay protections settings

    Directory of Open Access Journals (Sweden)

    Buha Danilo

    2016-01-01

    Full Text Available The relay protection settings performed in the largest thermal powerplant (TE "Nikola Tesla B" are reffered and explained in this paper. The first calculation step is related to the coordination of the maximum stator current limiter settings, the overcurrent protection with inverse characteristics settings and the permitted overload of the generator stator B1. In the second calculation step the settings of impedance generator protection are determined, and the methods and criteria according to which the calculations are done are described. Criteria used to provide the protection to fulfill the backup protection role in the event of malfunction of the main protection of the transmission system. are clarified. The calculation of all protection functions (32 functions of generator B1 were performed in the project "Coordination of relay protection blocks B1 and B2 with the system of excitation and power system protections -TENT B".

  12. Reactor protection systems of 500 MWe PHWRs

    Energy Technology Data Exchange (ETDEWEB)

    Mallik, G; Kelkar, M G; Apte, Ravindra [C and I Group, Nuclear Power Corporation, Mumbai (India)

    1997-03-01

    The 500 MWe PHWR has two totally independent, diverse, fast acting shutdown system called Shutdown System 1 (SDS 1) and Shutdown System 2 (SDS 2). The trip generation circuitry of SDS 1 and SDS 2 are known as Reactor Protection System 1 (RPS 1) and Reactor Protection System 2 (RPS 2) respectively. Some of the features specific to 500 MWe reactors are Core Over Power Protection System (COPPS) based upon in core Self Powered Neutron Detector (SPND) signals, use of local two out of three coincidence logic and adoption of overlap testing for RPS 2, use of Fine Impulse Testing (FIT) in RPS 2, testing of the final control elements namely electro-magnetic clutch of individual Shutoff Rods (SRs) of SDS 1 and all the fast acting valves of SDS 2, etc. The two shutdown systems have totally separate sets of sensors and associated signal processing circuitry as well as physical arrangements. A separate computerised test and monitoring unit is used for each of the two shutdown systems. Use of Programmable Digital Comparator (PDC) unit exclusively for reactor protection systems, has been adopted. The capability of PDC unit is enhanced and communication links are provided for its integration in over all system. The paper describes the design features of reactor protection systems. (author). 3 refs., 7 figs., 3 tabs.

  13. Evolution of the radiation protection system; L'evolution du systeme de protection radiologique

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, R.H. [International Commission on Radiological Protection, Stockholm (Sweden); Schieber, C.; Cordoliani, Y.S. [Societe Francaise de Radioprotection, 92 - Fontenay aux Roses (France); Brechignac, F. [CEA Cadarache, Institut de Radioprotection et de Surete Nucleaire, Dept. de Protection de l' Environnement, 13 - Saint Paul Lez Durance (France)

    2003-07-01

    The evolution of the system of radiological protection: justification for new ICRP recommendations, thoughts of the SFRP work group about the evolution of the system of radiation protection proposed by the ICRP, protection of environment against ionizing radiations seen by the ICRP are the three parts of this chapter. (N.C.)

  14. Protecting information in systems of systems

    NARCIS (Netherlands)

    Trivellato, D.

    2012-01-01

    Systems of systems are coalitions of autonomous and heterogeneous systems that collaborate to achieve a common goal. The component systems of a system of systems often belong to different security domains, which are governed by different authorities (hereafter called parties). Furthermore, systems

  15. Control rod blow out protection system

    International Nuclear Information System (INIS)

    Dietrich, J.R.; Flinn, W.S.; Groves, M.D.

    1979-01-01

    An absorber element blow-out protection system for a nuclear reactor having a pressure vessel through which a coolant is circulated. The blow-out protection system includes devices which hydraulically couple groups of guide tubes in which the absorber elements move, the coupling devices limiting coolant lift flow rate to a level commensurate with the raising of individual absorber elements but insufficient to raise a plurality of absorber elements simultaneously

  16. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2007-01-01

    The OECD Nuclear Energy Agency (NEA) has actively participated in discussions with the International Commission on Radiological Protection (ICRP) regarding the development of new recommendations that will replace those in ICRP Publication 60, which has long served as the international standard in this field. Part of this development process has involved the organisation of seven international workshops, including the First and Second Asian Regional Conferences on the Evolution of the System of Radiological Protection which took place in Tokyo, Japan in October 2002 and July 2004. The Third Asian Regional Conference was held on 5-6 July 2006, also in Tokyo. The main objective of these conferences was to ensure that the views and concerns of relevant Asian stakeholders, such as regulatory authorities, industry, professional societies and NGO, could be expressed and discussed with the ICRP. The three conferences provided the ICRP with specific views on how new recommendations could best be developed to address regulatory and implementation needs in the Asian context. These proceedings summarize the results and key discussions of the Third Asian Regional Conference. (author)

  17. Machine Protection System response in 2011

    CERN Document Server

    Zerlauth, M; Wenninger, J

    2012-01-01

    The performance of the machine protection system during the 2011 run is summarized in this paper. Following an analysis of the beam dump causes in comparison to the previous 2010 run, special emphasis will be given to analyse events which risked to exposed parts of the machine to damage. Further improvements and mitigations of potential holes in the protection systems as well as in the change management will be evaluated along with their impact on the 2012 run. The role of the restricted Machine Protection Panel ( rMPP ) during the various operational phases such as commissioning, the intensity ramp up and Machine Developments is being discussed.

  18. Autonomous systems for plant protection

    DEFF Research Database (Denmark)

    Griepentrog, Hans W.; Ruckelhausen, Arno; Jørgensen, Rasmus N.

    2010-01-01

    Advances in automation are demanded by the market mainly as a response to high labor costs. Robotic outdoor systems are ready to allow not only economically viable operations but also increased efficiency in agriculture, horticulture and forestry. The aim of this chapter is to give examples of au...

  19. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-11-01

    The design of an effective physical protection system (PPS) includes the determination of the PPS objectives, the initial design of a PPS, the evaluation of the design, and probably, the redesign or refinement of the system. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the PPS, that is, ''what to protect against whom.'' The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control devices, communication devices, procedures, and protective force personnel to meet the objectives of the system. Once a PPS is designed, it must be analyzed and evaluated to ensure it meets the PPS objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. After the system is installed, the threat and system parameters may change with time. If they do, the analysis must be performed periodically to ensure the system objectives are still being met

  20. Power system protection 1 principles and components

    CERN Document Server

    Association, Electricity Training

    1995-01-01

    The worldwide growth in demand for electricity has forced the pace of developments in electrical power system design to meet consumer needs for reliable, secure and cheap supplies. Power system protection, as a technology essential to high quality supply, is widely recognised as a specialism of growing and often critical importance, in which power system needs and technological progress have combined to result in rapid developments in policy and practice in recent years. In the United Kingdom, the need for appropriate training in power system protection was recognised in the early 1960s with t

  1. Distributed systems for protecting nuclear power stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-05-01

    The advantages of distributed control systems for the control of nuclear power stations are obviously of great interest. Some years ago, EPRI, (Electric Power Research Institute) showed that multiplexing the signals is technically feasible, that it enables the availability specifications to be met and costs to be reduced. Since then, many distributed control systems have been proposed by the manufacturers. This note offers some comments on the application of the distribution concept to protection systems -what should be distributed- and ends with a brief description of a protection system based on microprocessors for the pressurized power stations now being built in France [fr

  2. PCIe40 temperature protection system

    CERN Document Server

    Romero Aguilar, Angel

    2017-01-01

    PCIe40 is a high-throughput data-acquisition card based on PCI Express that is currently under development for the next upgrade of the LHCb experiment readout system. As part of this development, SMBus is intended to be used as a lightweight, out-of-band protocol to monitor the health of each data acquisition board. Starting from a simple prototype, the student will work on enabling SMBus communication between a COTS linux host and various on-board sensors, on top of existing linux facilities.

  3. [Artificial intelligence] AI for protection systems

    Energy Technology Data Exchange (ETDEWEB)

    Aggarwal, R.; Johns, A.

    1997-12-31

    The reliable operation of large power systems with small stability margins is highly dependent on control systems and protection devices. Progress in the field of microprocessor systems and demanding requirements in respect of the performance of protective relays are the reasons for digital device applications to power system protection. The superiority of numeric protection over its analogue alternatives is attributed to such factors as accurate extraction of the fundamental voltage and current components through filtering, functional benefits resulting from multi-processor design and extensive self-monitoring, etc. However, all these reasons have not led to a major impact on speed, sensitivity and selectivity of primary protective relays, and the gains are only marginal; this is so because conventional digital relays still rely on deterministic signal models and a heuristic approach for decision making, so that only a fraction of the information contained within voltage and current signals as well as knowledge about the plant to be protected is used. The performance of digital relays may be substantially improved if the decision making is based on elements of artificial intelligence (AI). (Author)

  4. Protecting Information in Systems of Systems

    NARCIS (Netherlands)

    Trivellato, Daniel; Zannone, Nicola; Etalle, Sandro

    2011-01-01

    Systems of Systems (SoS) are dynamic, distributed coalitions of autonomous and heterogeneous systems that collaborate to achieve a common goal. While offering several advantages in terms of scalability and flexibility, the SoS paradigm has a strong impact on system interoperability and on the

  5. Advanced Protection & Service Restoration for FREEDM Systems

    Science.gov (United States)

    Singh, Urvir

    A smart electric power distribution system (FREEDM system) that incorporates DERs (Distributed Energy Resources), SSTs (Solid State Transformers - that can limit the fault current to two times of the rated current) & RSC (Reliable & Secure Communication) capabilities has been studied in this work in order to develop its appropriate protection & service restoration techniques. First, a solution is proposed that can make conventional protective devices be able to provide effective protection for FREEDM systems. Results show that although this scheme can provide required protection but it can be quite slow. Using the FREEDM system's communication capabilities, a communication assisted Overcurrent (O/C) protection scheme is proposed & results show that by using communication (blocking signals) very fast operating times are achieved thereby, mitigating the problem of conventional O/C scheme. Using the FREEDM System's DGI (Distributed Grid Intelligence) capability, an automated FLISR (Fault Location, Isolation & Service Restoration) scheme is proposed that is based on the concept of 'software agents' & uses lesser data (than conventional centralized approaches). Test results illustrated that this scheme is able to provide a global optimal system reconfiguration for service restoration.

  6. Power system EMP protection. Final report

    International Nuclear Information System (INIS)

    Marable, J.H.; Barnes, P.R.; Nelson, D.B.

    1975-05-01

    Voltage transients induced in electric power lines and control circuits by the electromagnetic pulse (EMP) from high-altitude nuclear detonations may cause widespread power failure and damage in electric power systems. This report contains a parametric study of EMP power line surges and discusses protective measures to minimize their effects. Since EMP surges have considerably greater rates of rise than lightning surges, recommended standards and test procedures are given to assure that surge arresters protect equipment from damage by EMP. Expected disturbances and damage to power systems are reviewed, and actions are presented which distribution companies can take to counter them. These include backup communications methods, stockpiling of vulnerable parts, repair procedures, and dispatcher actions to prevent blackout from EMP-caused instabilities. A long-range program is presented for improving distributors' protection against EMP. This involves employee training, hardware protection for power and control circuits, and improvement of plans for emergency action. (U.S.)

  7. DLP-systems: Protection from Insiders

    Directory of Open Access Journals (Sweden)

    Ivan Sergeevich Boridko

    2013-02-01

    Full Text Available In the paper the necessity of further introduction of modern systems of information protection against internal leaks, including DLP-systems, is justified. The issues of development of training specialists in the field of information security is considered.

  8. Renovation of the cathodic protection system

    NARCIS (Netherlands)

    Schuten, G.; Leggedoor, J.; Polder, R.B.; Peelen, W.H.A.

    2003-01-01

    The first system for Cathodic Protection of concrete in the Netherlands was applied to a one bicycle lane of a bridge suffering corrosion due to de-icing salt penetration in 1986. This CP system was based on the Ferex 100S conducting polymer cable anode in a cementitious overlay. Its functioning was

  9. Future Interoperability of Camp Protection Systems (FICAPS)

    Science.gov (United States)

    Caron, Sylvie; Gündisch, Rainer; Marchand, Alain; Stahl, Karl-Hermann

    2013-05-01

    The FICAPS Project has been established as a Project of the European Defence Agency based on an initiative of Germany and France. Goal of this Project was to derive Guidelines, which by a proper implementation in future developments improve Camp Protection Systems (CPS) by enabling and improving interoperability between Camp Protection Systems and its Equipments of different Nations involved in multinational missions. These Guidelines shall allow for: • Real-time information exchange between equipments and systems of different suppliers and nations (even via SatCom), • Quick and easy replacement of equipments (even of different Nations) at run-time in the field by means of plug and play capability, thus lowering the operational and logistic costs and making the system highly available, • Enhancement of system capabilities (open and modular systems) by adding new equipment with new capabilities (just plug-in, automatic adjustment of the HMI Human Machine Interface) without costly and time consuming validation and test on system level (validation and test can be done on Equipment level), Four scenarios have been identified to summarize the interoperability requirements from an operational viewpoint. To prove the definitions given in the Guideline Document, a French and a German Demonstration System, based on existing national assets, were realized. Demonstrations, showing the capabilities given by the defined interoperability requirements with respect to the operational scenarios, were performed. Demonstrations included remote control of a CPS by another CPS, remote sensor control (Electro-Optic/InfraRed EO/IR) and remote effector control. This capability can be applied to extend the protection area or to protect distant infrastructural assets Demonstrations have been performed. The required interoperability functionality was shown successfully. Even if the focus of the FICAPS project was on camp protection, the solution found is also appropriate for other

  10. Fire protection system operating experience review for fusion applications

    International Nuclear Information System (INIS)

    Cadwallader, L.C.

    1995-12-01

    This report presents a review of fire protection system operating experiences from particle accelerator, fusion experiment, and other applications. Safety relevant operating experiences and accident information are discussed. Quantitative order-of-magnitude estimates of fire protection system component failure rates and fire accident initiating event frequencies are presented for use in risk assessment, reliability, and availability studies. Safety concerns with these systems are discussed, including spurious operation. This information should be useful to fusion system designers and safety analysts, such as the team working on the Engineering Design Activities for the International Thermonuclear Experimental Reactor

  11. Fire protection system operating experience review for fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Cadwallader, L.C.

    1995-12-01

    This report presents a review of fire protection system operating experiences from particle accelerator, fusion experiment, and other applications. Safety relevant operating experiences and accident information are discussed. Quantitative order-of-magnitude estimates of fire protection system component failure rates and fire accident initiating event frequencies are presented for use in risk assessment, reliability, and availability studies. Safety concerns with these systems are discussed, including spurious operation. This information should be useful to fusion system designers and safety analysts, such as the team working on the Engineering Design Activities for the International Thermonuclear Experimental Reactor.

  12. Advanced physical protection systems for facilities and transportation

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Sandia Laboratories is developing advanced physical protection safeguards in order to improve the security of special nuclear materials, facilities, and transportation. Computer models are being used to assess the cost-effectiveness of alternative systems for protecting facilities against external attack which may include internal assistance, and against internal theft or sabotage. Physical protection elements such as admittance controls, portals and detectors, perimeter and interior intrusion alarms, fixed and remotely activated barriers, and secure communications are being evaluated, adapted, and where required, developed. New facilities safeguards concepts which involve ''control loops'' between physical protection and materials control elements are being evolved jointly between Sandia Laboratories and Los Alamos Scientific Laboratory. Special vehicles and digital communications equipment have been developed for the ERDA safe-secure transportation system. The current status and direction of these activities are surveyed

  13. Advanced physical protection systems for facilities and transportation

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Sandia Laboratories is developing advanced physical protection safeguards in order to improve the security of special nuclear materials, facilities, and transportation. Computer models are being used to assess the cost-effectiveness of alternative systems for protecting facilities against external attack which may include internal assistance, and against internal theft or sabotage. Physical protection elements such as admittance controls, portals and detectors, perimeter and interior intrusion alarms, fixed and remotely-activated barriers, and secure communications are being evaluated, adapted, and where required, developed. New facilities safeguards concepts which involve (control loops) between physical protection and materials control elements are being evolved jointly between Sandia Laboratories and Los Alamos Scientific Laboratory. Special vehicles and digital communications equipment have been developed for the ERDA safe-secure transportation system. The current status and direction of these activities are surveyed

  14. Improved core protection calculator system algorithm

    International Nuclear Information System (INIS)

    Yoon, Tae Young; Park, Young Ho; In, Wang Kee; Bae, Jong Sik; Baeg, Seung Yeob

    2009-01-01

    Core Protection Calculator System (CPCS) is a digitized core protection system which provides core protection functions based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels which adapted a two out of four trip logic. CPCS algorithm improvement for the newly designed core protection calculator system, RCOPS (Reactor COre Protection System), is described in this paper. New features include the improvement of DNBR algorithm for thermal margin, the addition of pre trip alarm generation for auxiliary trip function, VOPT (Variable Over Power Trip) prevention during RPCS (Reactor Power Cutback System) actuation and the improvement of CEA (Control Element Assembly) signal checking algorithm. To verify the improved CPCS algorithm, CPCS algorithm verification tests, 'Module Test' and 'Unit Test', would be performed on RCOPS single channel facility. It is expected that the improved CPCS algorithm will increase DNBR margin and enhance the plant availability by reducing unnecessary reactor trips

  15. Thermal Management and Thermal Protection Systems

    Science.gov (United States)

    Hasnain, Aqib

    2016-01-01

    During my internship in the Thermal Design Branch (ES3), I contributed to two main projects: i) novel passive thermal management system for future human exploration, ii) AVCOAT undercut thermal analysis. i) As NASA prepares to further expand human and robotic presence in space, it is well known that spacecraft architectures will be challenged with unprecedented thermal environments. Future exploration activities will have the need of thermal management systems that can provide higher reliability, mass and power reduction and increased performance. In an effort to start addressing the current technical gaps the NASA Johnson Space Center Passive Thermal Discipline has engaged in technology development activities. One of these activities was done through an in-house Passive Thermal Management System (PTMS) design for a lunar lander. The proposed PTMS, functional in both microgravity and gravity environments, consists of three main components: a heat spreader, a novel hybrid wick Variable Conductance Heat Pipe (VCHP), and a radiator. The aim of this PTMS is to keep electronics on a vehicle within their temperature limits (0 and 50 C for the current design) during all mission phases including multiple lunar day/night cycles. The VCHP was tested to verify its thermal performance. I created a thermal math model using Thermal Desktop (TD) and analyzed it to predict the PTMS performance. After testing, the test data provided a means to correlate the thermal math model. This correlation took into account conduction and convection heat transfer, representing the actual benchtop test. Since this PTMS is proposed for space missions, a vacuum test will be taking place to provide confidence that the system is functional in space environments. Therefore, the model was modified to include a vacuum chamber with a liquid nitrogen shroud while taking into account conduction and radiation heat transfer. Infrared Lamps were modelled and introduced into the model to simulate the sun

  16. Protective activity of Lentinan in experimental tuberculosis.

    Science.gov (United States)

    Markova, Nadya; Kussovski, Vesselin; Drandarska, Ivanka; Nikolaeva, Sascha; Georgieva, Neli; Radoucheva, Tatyana

    2003-10-01

    Protective effects of Lentinan (Ajinomoto, Japan) against Mycobacterium tuberculosis infection were studied by in vitro and in vivo mouse models. The effectiveness of Lentinan administrated intraperitoneally (i.p.) before infection at a dose of 1 mg/kg three times at 2-day intervals was monitored in vivo by several parameters (body temperature; spleen weight; CFU counts of M. tuberculosis in spleen, liver and lung; and histomorphological observations). Peritoneal macrophages obtained from animals treated with Lentinan were greatly stimulated, as assayed by establishing their number, acid phosphatase activity, H2O2 production and killing ability against M. tuberculosis in vitro. The in vivo model demonstrated that administration of Lentinan before infection can mobilize host defense potential and reduce mycobacterial infection.

  17. Adoption of digital safety protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Z.

    1998-01-01

    The application of micro-processor-based digital controllers has been widely propagated among various industries in recent years. While in the nuclear power plant industry, the application of them has also been expanding gradually starting from non-safety related systems, taking advantage of their reliability and maintainability over the conventional analog devices. Based on the careful study of the feasibility of digital controllers to the safety protection system, the Tokyo Electric Power Company proposed on May 1989 the adoption of digital controllers to the safety protection system in the Application for Permission of Establishment of Kashiwazaki-Kariwa units 6 and 7 (ABWR-1350Mwe each). MITI, Ministry of International Trade and Industry, the Japanese regulatory body for electric power generating facilities, had approved this application after careful review. This paper describes a series of supporting activities leading to the MITI's approval of the digital safety protection system and the MITI's licensing activities. (author)

  18. Cold Vacuum Drying facility fire protection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) fire protection system (FPS). The FPS provides fire detection, suppression, and loss limitation for the CVDF structure, personnel, and in-process spent nuclear fuel. The system provides, along with supporting interfacing systems, detection, alarm, and activation instrumentation and controls, distributive piping system, isolation valves, and materials and controls to limit combustibles and the associated fire loadings

  19. Reliability of redundant structures of nuclear reactor protection systems

    International Nuclear Information System (INIS)

    Vojnovic, B.

    1983-01-01

    In this paper, reliability of various redundant structures of PWR protection systems has been analysed. Structures of reactor tip systems as well as the systems for activation of safety devices have been presented. In all those systems redundancy is achieved by means of so called majority voting logic ('r out of n' structures). Different redundant devices have been compared, concerning probability of occurrence of safe as well as unsafe failures. (author)

  20. Televison assessment and identification system for the plutonium protection system

    International Nuclear Information System (INIS)

    Greenwoll, D.A.

    1979-02-01

    This report covers the selection, description, and use of the components comprising the Television Assessment and Identification System in the Hanford Plutonium Protection System. This work was sponsored by the Department of Energy/Office of Safeguards and Security (DOE/OSS) as part of the overall Sandia Fixed Facility Physical Protection Program

  1. Distance Protection for Microgrids in Distribution System

    DEFF Research Database (Denmark)

    Lin, Hengwei; Liu, Chengxi; Guerrero, Josep M.

    2015-01-01

    protection decreased. This paper adopts distance protection for one mid-voltage level microgrid in Aalborg, Denmark. Different operation modes of the network are analyzed and tested in the paper. The simulation results show that the variations of the fault currents seen by the forward relays are much larger...... than the backward relays. Meanwhile, the fault currents change little with the randomness of renewable energy except the intermittence. Finally, it shows that the designed distance protection has satisfactory performance to clear the various faults.......Owing to the increasing penetration of distributed generation, there are some challenges for the conventional protection in distribution system. Bidirectional power flow and variable fault current because of the various operation modes may lead to the selectivity and sensitivity of the overcurrent...

  2. Protection and environmental supervision activities at ROMAG PROD Plant

    International Nuclear Information System (INIS)

    Chilom, Rodica

    2002-01-01

    The protection and environmental supervision activity at ROMAG PROD heavy water plant is embodied in the very production process. The environmental supervision is done by: 1. the sensing system for H 2 S which monitors H 2 S and other gases 24 h/day on three zones of production storage and transport of H 2 S; 2. daily tightness checking of the installations working with H 2 S; 3. daily analytical checking of the air and water pollutants at seven air sampling checking points in dwelled zones, at the industrial area boundary and at purification stations and water waste discharge points. The water and air environmental components are protected through safe operation of the heavy water installations and of the flue gas installation. The water protection is ensured through optimal operation of the purification facilities, namely: the purification of the water resulting from the isotopic exchange; acid water neutralization station which process the waste water collected from the whole plant; neutralization reservoir for water resulting from ionic exchange; purification station of the sulfate waters resulting from the H 2 S fabrications installation; mud pool. The ROMAG PROD Plant operates according to the ISO 9001 and ISO 14001 standards and reports regularly its activity to the Environmental Protection and Water System Management Authority

  3. Dependability Evaluation of Advanced Diverse Protection System

    International Nuclear Information System (INIS)

    Oh, Yang Gyun; Lee, Yoon Hee; Sohn, Se Do; Baek, Seung Min; Lee, Sang Jeong

    2014-01-01

    For the mitigation of anticipated transients without scram (ATWS) as well as common cause failure (CCF) within the plant protection system (PPS) and the emergency safety feature . component control system (ESF-CCS), the diverse protection system (DPS) has been designed by KEPCO Engineering and Construction Company. Recently KEPCO E and C has developed the advanced diverse protection system (ADPS), which has four redundant channels, in an attempt to enhance a fault-tolerant capability of the system. For the evaluation of overall system improvement effects of the ADPS compared with the DPS, the dependability evaluation results are described herein. For all dependability attributes, this paper suggests a practical dependability evaluation method which uses quantitative dependability scores and indices. An overall dependability evaluation index (DEI) for the ADPS is evaluated with the average value of reliability/ security/maintainability/safety indices (i.e., RID, SID, MID, and SID') for dependability. The evaluation results show that the DEI value of ADPS can be improved by approximately 23% compared with that of the DPS, thanks to its fault-tolerant system architecture, software design changes, and external interface design features. Several suggestions have been made, in this paper, of an overall quantitative dependability evaluation method for the nuclear instrumentation and control (I and C) systems including the DPS and ADPS, and the usefulness of dependability evaluation on nuclear I and C systems has been confirmed

  4. Europe's contribution to implementation of a radiation protection system

    International Nuclear Information System (INIS)

    Lecomte, J.F.

    2010-01-01

    What is commonly referred to as a radiation protection system is a range of scientific considerations, principles and rules, the aim of which is to contribute to an appropriate level of protection of individuals and the environment against the harmful effects of exposure to ionising radiation, without excessively limiting desirable human activities which can be associated with such exposure (see ICRP Publication 103). This system is essentially based on an international consensus. The European level only concerns the Member States of the Union but it is crucial that it constitute the final, legally binding step prior to the definition of national regulations. The European radiation protection system (the EURATOM Treaty and its derived legislation) is presented below, not from the legal perspective but from a contextual viewpoint. Research activities are not discussed here. (author)

  5. An integrated numerical protection system (SPIN)

    International Nuclear Information System (INIS)

    Savornin, J.L.; Bouchet, J.M.; Furet, J.L.; Jover, P.; Sala, A.

    1978-01-01

    Developments in technology have now made it possible to perform more sophisticated protection functions which follow more closely the physical phenomena to be monitored. For this reason the Commissariat a l'energie atomique, Merlin-Gerin, Cerci and Framatome have embarked on the joint development of an Integrated Numerical Protection System (SPIN) which will fulfil this objective and will improve the safety and availability of power stations. The system described involves the use of programmed numerical techniques and a structure based on multiprocessors. The architecture has a redundancy of four. Throughout the development of the project the validity of the studies was confirmed by experiments. A first numerical model of a protection function was tested in the laboratory and is now in operation in a power station. A set of models was then introduced for checking the main components of the equipment finally chosen prior to building and testing a prototype. (author)

  6. Management information system applied to radiation protection services

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur

    2013-01-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  7. Management information system applied to radiation protection services

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur, E-mail: pabloag@cdtn.br, E-mail: lss@cdtn.br, E-mail: gmf@cdtn.br, E-mail: arthurqof@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  8. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2004-01-01

    The development of new radiological protection recommendations by the International Commission on Radiological Protection (ICRP) continues to be a strategically important undertaking, both nationally and internationally. With the growing recognition of the importance of stakeholder aspects in radiological protection decision making, regional and cultural aspects have also emerged as having potentially significant influence on how protection of the public, workers and the environment are viewed. Differing cultural aspects should therefore be considered by the ICRP in its development of new recommendations. Based on this assumption, the NEA organised the Asian Regional Conference on the Evolution of the System of Radiological Protection to express and explore views from the Far East. Held in Tokyo on 24-25 October 2002, the conference included presentations by the ICRP Chair as well as by radiological protection experts from Japan, the Republic of Korea, China and Australia. The distinct views and needs of these countries were discussed in the context of their regional and cultural heritages. These views, along with a summary of the conference results, are presented in these proceedings. (author)

  9. 78 FR 77574 - Protection System Maintenance Reliability Standard

    Science.gov (United States)

    2013-12-24

    ... commissioning of power system protection systems.\\55\\ NERC commits in its Comments to keep the Commission... commissioning of power system protection systems.\\62\\ As explained in the NOPR, our concern is with a protection... protection system, ``resulting in line relays being placed in service with the incorrect transformer ratio...

  10. Additional reactor protection system of RBMK-1500

    International Nuclear Information System (INIS)

    1999-01-01

    Analysis of anticipated transients without scram of RBMK-1500 reactor showed that additional reactor protection system is required. Data of accident analysis in the case of loose of external electric power and loose of vacuum in condensers of turbines are provided

  11. Validation of reactor core protection system

    International Nuclear Information System (INIS)

    Lee, Sang-Hoon; Bae, Jong-Sik; Baeg, Seung-Yeob; Cho, Chang-Ho; Kim, Chang-Ho; Kim, Sung-Ho; Kim, Hang-Bae; In, Wang-Kee; Park, Young-Ho

    2008-01-01

    Reactor COre Protection System (RCOPS), an advanced core protection calculator system, is a digitized one which provides core protection function based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels adapted a two-out-of-four trip logic. System configuration, hardware platform and an improved algorithm of the newly designed core protection calculator system are described in this paper. One channel of RCOPS was implemented as a single channel facility for this R and D project where we performed final integration software testing. To implement custom function blocks, pSET is used. Software test is performed by two methods. The first method is a 'Software Module Test' and the second method is a 'Software Unit Test'. New features include improvement of core thermal margin through a revised on-line DNBR algorithm, resolution of the latching problem of control element assembly signal and addition of the pre-trip alarm generation. The change of the on-line DNBR calculation algorithm is considered to improve the DNBR net margin by 2.5%-3.3%. (author)

  12. New evaluation system for antisabotage physical protection

    International Nuclear Information System (INIS)

    Itakura, Shuichiro; Nakagome, Yoshihiro

    2008-01-01

    The discussion on an appropriate level of physical protection has not been elaborated so far because of the confidentiality of its nature, thus resulting in a lack of consensus on this issue. In view of this context, a new system for the evaluation of antisabotage physical protection systems is proposed in this paper, in which we introduce openness to a certain extent in the process of the evaluation. The proposed system is composed of the following three elements; (1) establishment of an evaluation basis threat (EBT), which should be less strong but more likely to occur than the design basis threat (DBT); (2) employment of realistic standard scenarios in the process of evaluation; (3) disclosure of results of evaluation implemented based on the above EBT and standard scenarios. It is expected that this considerably open system will foment peace of mind among citizens as well as create a deterrent effect that would minimize the occurrence of sabotage on nuclear facilities. (author)

  13. Safety Analysis for Power Reactor Protection System

    International Nuclear Information System (INIS)

    Eisawy, E.A.; Sallam, H.

    2012-01-01

    The main function of a Reactor Protection System (RPS) is to safely shutdown the reactor and prevents the release of radioactive materials. The purpose of this paper is to present a technique and its application for used in the analysis of safety system of the Nuclear Power Plant (NPP). A more advanced technique has been presented to accurately study such problems as the plant availability assessments and Technical Specifications evaluations that are becoming increasingly important. The paper provides the Markov model for the Reactor Protection System of the NPP and presents results of model evaluations for two testing policies in technical specifications. The quantification of the Markov model provides the probability values that the system will occupy each of the possible states as a function of time.

  14. Swedish Radiation Protection Institute: information activities

    International Nuclear Information System (INIS)

    Persson, Lars

    2000-01-01

    The purpose of SSI's Information and PR Service is to broaden public awareness of radiation and radiation risks as well as to fulfill other performance goals. SSI achieves this through its advisory, educational and informative activities. SSI publishes two external magazines, Stralskyddsnytt and SSI News. Stralskyddsnytt - which is available in Swedish only - has a circulation of 2,000 and is published four times a year. SSI News - which is in English - is published twice a year and has a circulation of about 1,800. Another important channel of communication is the web site (www.ssi.se). Taking advantage of PUSH technology, SSI also distributes, by e-mail, press releases and other important information on radiation to radiation protection professionals in Sweden. SSI continuously monitors news by subscribing to a press clipping service. SSI Training is a commercial unit within the Information and PR Service. A policy for mass media contacts exists as well as a policy for internal communication. SSI has a graphic profile. SSI has a specialized research library. (author)

  15. Swedish radiation protection institute. Information activities

    International Nuclear Information System (INIS)

    Persson, Lars

    1999-01-01

    The purpose of SSI's information and PR Service is to broaden public awareness of radiation and radiation risks as well as to fulfil other performance goals. SSI achieves this through its advisory, educational and informative activities. SSI publishes two external magazines, Straalskyddsnytt and SSI News. Straalskyddsnytt - which is available in Swedish only - has a circulation of 2,400 and is published four times a year. SSI News - which is in English - is published twice a year and has a circulation of about 1,500. Another important channel of communication is the web site (www.ssi.se). Taking advantage of PUSH technology, SSi also distributes, by e-mail, press releases and other important information of radiation to radiation protection professionals in Sweden. SSI continuously monitors news by subscribing to a press clipping service. SSI Training is a commercial unit within the Information and PR Service. A policy for mass media contacts exists as well as a policy for internal communication. SSI has a graphic profile. SSI has a specialised research library. (au)

  16. Addressing Circuitous Currents MVDC Power Systems Protection

    Science.gov (United States)

    2017-12-31

    Addressing Circuitous Currents MVDC Power Systems Protection 5b. GRANT NUMBER N00014-16-1-3113 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR($) Sd. PROJECT NUMBER...efficiency. A challenge with DC distribution is electrical protection . Z-source DC breakers alt! an pti n b&i g cvr.sidcrcd and this w rk ~xplores...zonal distribution, electric ship 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF a. REPORT b. ABSTRACT c. THIS PAGE ABSTRACT u u u uu 18. NUMBER

  17. Magnetic field generated by lightning protection system

    Science.gov (United States)

    Geri, A.; Veca, G. M.

    1988-04-01

    A lightning protection system for today's civil buildings must be electromagnetically compatible with the electronic equipment present in the building. This paper highlights a mathematic model which analyzes the electromagnetic effects in the environment in which the lightning protection system is. This model is developed by means of finite elements of an electrical circuit where each element is represented by a double pole circuit according to the trapezoidal algorithm developed using the finite difference method. It is thus possible to analyze the electromagnetic phenomena associated with the transient effects created by the lightning stroke even for a high-intensity current. Referring to an elementary system comprised of an air terminal, a down conductor, and a ground terminal, numerical results are here laid out.

  18. Development of a Smart Residential Fire Protection System

    Directory of Open Access Journals (Sweden)

    Juhwan Oh

    2013-01-01

    Full Text Available Embedded system is applied for the development of smart residential fire detection and extinguishing system. Wireless communication capability is integrated into various fire sensors and alarm devices. The system activates the fire alarm to warn occupants, executes emergency and rescue calls to remote residents and fire-fighting facility in an intelligent way. The effective location of extra-sprinklers within the space of interest for the fire extinguishing system is also investigated. Actual fire test suggests that the developed wireless system for the smart residential fire protection system is reliable in terms of sensors and their communication linkage.

  19. Expert systems for protective monitoring of facilities

    International Nuclear Information System (INIS)

    Carr, K.R.

    1987-01-01

    In complex plants, the possibility of serious operator error always exists to some extent, but, this can be especially true during an experiment or some other unusual exercise. Possible contributing factors to operational error include personnel fatigue, misunderstanding in communication, mistakes in executing orders, uncertainty about the delegated authority, pressure to meet a demanding schedule, and a lack of understanding of the possible consequences of deliberate violations of the facility's established operating procedures. Authoritative reports indicate that most of these factors were involved in the disastrous Russian Chernobyl-4 nuclear reactor accident in April 1986, which, ironically, occurred when a safety experiment was being conducted. Given the computer hardware and software now available for implementing expert systems together with integrated signal monitoring and communications, plant protection could be enhanced by an expert system with extended features to monitor the plant. The system could require information from the operators on a rigidly enforced schedule and automatically log in and report on a scheduled time basis to authorities at a central remote site during periods of safe operation. Additionally, the system could warn an operator or automatically shut down the plant in case of dangerous conditions, while simultaneously notifying independent, responsible, off-site personnel of the action taken. This approach would provide protection beyond that provided by typical facility scram circuits. This paper presents such an approach to implementing an expert system for plant protection, together with specific hardware and software configurations. The Chernobyl accident is used as the basis of discussion

  20. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Bergman, W.; Ford, H.W.; Lipska, A.E.

    1980-01-01

    The goal of this project is to find countermeasures to protect HEPA filters in exit ventilation ducts from the heat and smoke generated by fire. Several methods for partially mitigating the smoke exposure to the HEPA filters were identified through testing and analysis. These independently involve controlling the fuel, controlling the fire, and intercepting the smoke aerosol prior to its sorption on the HEPA filter. Exit duct treatment of aerosols is not unusual in industrial applications and involves the use of scrubbers, prefilters, and inertial impaction, depending on the size, distribution, and concentration of the subject aerosol. However, when these unmodified techniques were applied to smoke aerosols from fires on materials, common to experimental laboratories of LLNL, it was found they offered minimal protection to the HEPA filters. Ultimately, a continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. This technique is capable of protecting HEPA filters over the total duration of the test fires. The reason for success involved the modificaton of the prefiltration media. Commercially available filter media has a particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, we laminated rolling filter media with the desired properties. It is not true that the use of rolling prefilters solely to protect HEPA filters from fire-generated smoke aerosols is cost effective in every type of containment system, especially if standard fire-protection systems are available in the space. But in areas of high fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  1. Advanced worker protection system. Topical report, Phase I

    Energy Technology Data Exchange (ETDEWEB)

    Myers, J.

    1995-07-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system, maintenance, and dramatically improve worker productivity through longer duration work cycles.

  2. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.; Beason, D.; Bergman, V.; Creighton, J.; Ford, H.; Lipska, A.

    1980-01-01

    The goal of this project is to find countermeasures to protect High Efficiency Particulate Air (HEPA) filters, in exit ventilation ducts, from the heat and smoke generated by fire. Initially, methods were developed to cool fire-heated air by fine water spray upstream of the filters. It was recognized that smoke aerosol exposure to HEPA filters could also cause disruption of the containment system. Through testing and analysis, several methods to partially mitigate the smoke exposure to the HEPA filters were identified. A continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. The technique is capable of protecting HEPA filters over the total time duration of the test fires. The reason for success involved the modification of the prefiltration media. Commercially available filter media has particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, rolling filter media were laminated with the desired properties. The approach was Edisonian, but truncation in short order to a combination of prefilters was effective. The application of this technique was qualified, since it is of use only to protect HEPA filters from fire-generated smoke aerosols. It is not believed that this technique is cost effective in the total spectrum of containment systems, especially if standard fire protection systems are available in the space. But in areas of high-fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  3. Protective underpressure system for nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    A vacuum protection system for a nuclear reactor is described containng the possible accident in the immediate area where it happened. The system uses underpressure in the air-tight primary circuit jacket. Immediately after the accident, part of air is forced out from the area where coolant is being lost to another area which is then separated from the accident area. The desired underpressure is attained by steam condensation. A system diagram is shown and the time-dependent pressure changes in the contained areas are presented. (J.B.)

  4. Incipient fault detection and power system protection for spaceborne systems

    Science.gov (United States)

    Russell, B. Don; Hackler, Irene M.

    1987-01-01

    A program was initiated to study the feasibility of using advanced terrestrial power system protection techniques for spacecraft power systems. It was designed to enhance and automate spacecraft power distribution systems in the areas of safety, reliability and maintenance. The proposed power management/distribution system is described as well as security assessment and control, incipient and low current fault detection, and the proposed spaceborne protection system. It is noted that the intelligent remote power controller permits the implementation of digital relaying algorithms with both adaptive and programmable characteristics.

  5. Software reliability and safety in nuclear reactor protection systems

    International Nuclear Information System (INIS)

    Lawrence, J.D.

    1993-11-01

    Planning the development, use and regulation of computer systems in nuclear reactor protection systems in such a way as to enhance reliability and safety is a complex issue. This report is one of a series of reports from the Computer Safety and Reliability Group, Lawrence Livermore that investigates different aspects of computer software in reactor National Laboratory, that investigates different aspects of computer software in reactor protection systems. There are two central themes in the report, First, software considerations cannot be fully understood in isolation from computer hardware and application considerations. Second, the process of engineering reliability and safety into a computer system requires activities to be carried out throughout the software life cycle. The report discusses the many activities that can be carried out during the software life cycle to improve the safety and reliability of the resulting product. The viewpoint is primarily that of the assessor, or auditor

  6. Software reliability and safety in nuclear reactor protection systems

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, J.D. [Lawrence Livermore National Lab., CA (United States)

    1993-11-01

    Planning the development, use and regulation of computer systems in nuclear reactor protection systems in such a way as to enhance reliability and safety is a complex issue. This report is one of a series of reports from the Computer Safety and Reliability Group, Lawrence Livermore that investigates different aspects of computer software in reactor National Laboratory, that investigates different aspects of computer software in reactor protection systems. There are two central themes in the report, First, software considerations cannot be fully understood in isolation from computer hardware and application considerations. Second, the process of engineering reliability and safety into a computer system requires activities to be carried out throughout the software life cycle. The report discusses the many activities that can be carried out during the software life cycle to improve the safety and reliability of the resulting product. The viewpoint is primarily that of the assessor, or auditor.

  7. Sub-assembly accident protection instrumentation systems

    International Nuclear Information System (INIS)

    Vaughan, G.J.; Lunt, A.R.W.; Evans, N.J.; Lawrence, L.A.J.

    1982-01-01

    The possibility of an incident in a sub-assembly progressing to the stage at which the whole core may be at hazard has to be guarded against. It is proposed that for CDFR specific instrumentation will be provided to protect against this incident. Three such systems are described, these are: Acoustic Boiling Noise Detection, Burst Pin Detection and Individual Sub-Assembly Thermocouple (ISAT) monitoring. In the ISAT case, multiplexers and microprocessors are employed, using novel techniques to ensure failure-to-safety. The role of these systems and the implementation of them in the reactor design are also considered. It is concluded that sufficient protection can be provided for both core and breeder sub-assemblies

  8. Development of In-Core Protection System

    International Nuclear Information System (INIS)

    Cho, J. H; Kim, C. H.; Kim, J. H.; Jeong, S. H.; Sohn, S. D.; BaeK, S. M.; YOON, J. H.

    2016-01-01

    In-core Protection System (ICOPS) is an on-line digital computer system which continuously calculates Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) based on plant parameters to make trip decisions based on the computations. The function of the system is the same as that of Core Protection Calculator System (CPCS) and Reactor Core Protection System (RCOPS) which are applied to Optimized Power Reactor 1000 (OPR1000) and Advanced Power Reactor 1400 (APR1400). The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. To achieve this goal, several algorithms were newly developed and hardware and software design was updated. The functional design requirements document was developed by KEPCO-NF and the component design was conducted by Doosan. System design and software implementation were performed by KEPCO-E and C, and software Verification and Validation (V and V) was performed by KEPCO-E and C and Sure Softtech. The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. The function of I/O simulator was improved even though the hardware platform is the same as that of RCOPS for Shin-Hanul 1 and 2. SCADE was applied to the implementation of ICOPS software, and the V and V system for ICOPS which satisfies international standards was developed. Although several further detailed design works remain, the function of ICOPS has been confirmed. The ICOPS will be applied to APR+ project, and the further works will be performed in following project

  9. Development of In-Core Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J. H; Kim, C. H.; Kim, J. H.; Jeong, S. H.; Sohn, S. D.; BaeK, S. M.; YOON, J. H. [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    In-core Protection System (ICOPS) is an on-line digital computer system which continuously calculates Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) based on plant parameters to make trip decisions based on the computations. The function of the system is the same as that of Core Protection Calculator System (CPCS) and Reactor Core Protection System (RCOPS) which are applied to Optimized Power Reactor 1000 (OPR1000) and Advanced Power Reactor 1400 (APR1400). The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. To achieve this goal, several algorithms were newly developed and hardware and software design was updated. The functional design requirements document was developed by KEPCO-NF and the component design was conducted by Doosan. System design and software implementation were performed by KEPCO-E and C, and software Verification and Validation (V and V) was performed by KEPCO-E and C and Sure Softtech. The ICOPS has been developed to overcome the algorithm related obstacles in overseas project. The function of I/O simulator was improved even though the hardware platform is the same as that of RCOPS for Shin-Hanul 1 and 2. SCADE was applied to the implementation of ICOPS software, and the V and V system for ICOPS which satisfies international standards was developed. Although several further detailed design works remain, the function of ICOPS has been confirmed. The ICOPS will be applied to APR+ project, and the further works will be performed in following project.

  10. Lightning protection system for a wind turbine

    Science.gov (United States)

    Costin, Daniel P [Chelsea, VT; Petter, Jeffrey K [Williston, VT

    2008-05-27

    In a wind turbine (104, 500, 704) having a plurality of blades (132, 404, 516, 744) and a blade rotor hub (120, 712), a lightning protection system (100, 504, 700) for conducting lightning strikes to any one of the blades and the region surrounding the blade hub along a path around the blade hub and critical components of the wind turbine, such as the generator (112, 716), gearbox (708) and main turbine bearings (176, 724).

  11. Halon 1301 protection system for nuclear containments

    International Nuclear Information System (INIS)

    McHale, E.T.

    1981-01-01

    Halon 1301 can provide protection against any combustion hazard that hydrogen gas might present in an LWR containment following a loss-of-coolant accident. A development program was conducted, comprising analytical study, laboratory experiments and large-scale testing, to define the requirements for a Halon 1301 system and to examine certain operational problems that were hypothesized. Some results of the study are presented in this paper

  12. Protection of LV system against lightning

    OpenAIRE

    Yordanova Nedyalkova, Greta

    2010-01-01

    Lightning is a natural hazard and one of the greatest local mysteries. Scientists have not fully understood the mechanism of lightning. It is one of the most beautiful displays in nature and one of the nature's most dangerous phenomenon known to man. Overvoltage due to lightning is a very important problem of LV systems. Some lightning flashes damage buildings and a few kill or injure people and animals, either directly or indirectly, by causing fire and explosions. The need for protect...

  13. Beam loss monitor system for machine protection

    CERN Document Server

    Dehning, B

    2005-01-01

    Most beam loss monitoring systems are based on the detection of secondary shower particles which depose their energy in the accelerator equipment and finally also in the monitoring detector. To allow an efficient protection of the equipment, the likely loss locations have to be identified by tracking simulations or by using low intensity beams. If superconducting magnets are used for the beam guiding system, not only a damage protection is required but also quench preventions. The quench levels for high field magnets are several orders of magnitude below the damage levels. To keep the operational efficiency high under such circumstances, the calibration factor between the energy deposition in the coils and the energy deposition in the detectors has to be accurately known. To allow a reliable damage protection and quench prevention, the mean time between failures should be high. If in such failsafe system the number of monitors is numerous, the false dump probability has to be kept low to keep a high operation...

  14. Enhanced personal protection system for the PS

    CERN Multimedia

    Caroline Duc

    2013-01-01

    During the first long shutdown (LS1) a new safety system will be installed in the primary beam areas of the PS complex in order to bring the standard of personnel radiation protection at the PS into line with that of the LHC.   Pierre Ninin, deputy group leader of GS-ASE and responsible for the installation of the new PS complex safety system, in front of a new access control system. The LHC access control systems are state-of-the-art, whereas those of the injection chain accelerators were running the risk of becoming obsolete. For the past two years a project to upgrade the access and safety systems of the first links in the LHC accelerator chain has been underway to bring them into compliance with nuclear safety standards. These systems provide the personnel with automatic protection by limiting access to hazardous areas and by ensuring that nobody is present in the areas when the accelerator is in operation. By the end of 2013, the project teams will ha...

  15. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  16. Coherence protection in coupled quantum systems

    Science.gov (United States)

    Cammack, H. M.; Kirton, P.; Stace, T. M.; Eastham, P. R.; Keeling, J.; Lovett, B. W.

    2018-02-01

    The interaction of a quantum system with its environment causes decoherence, setting a fundamental limit on its suitability for quantum information processing. However, we show that if the system consists of coupled parts with different internal energy scales then the interaction of one part with a thermal bath need not lead to loss of coherence from the other. Remarkably, we find that the protected part can remain coherent for longer when the coupling to the bath becomes stronger or the temperature is raised. Our theory will enable the design of decoherence-resistant hybrid quantum computers.

  17. PG BN 1600 sodium fire protection system

    International Nuclear Information System (INIS)

    Bar, J.; Urbancik, L.

    1978-12-01

    A design was developed of a fire protection system for steam generator of a 1600 MW sodium cooled fast reactor (BN-1600). Chemical reactions are described of liquid sodium with atmospheric components and solid materials coming into contact with sodium in its release from the steam generator, and in safeguarding protection against sodium fires. The requirements for the purity of nitrogen as an atmosphere inert to liquid sodium are given. Characteristics and basic parameters are shown of level and spray fires, elementary terms are explained concerning the properties of aerosols formed during fires, the methods and means of release signalling and fire alarm are described as are fire precautions using fire-fighting equipment, modifying the support tank and the cell bottom and building sewage pits. The design of the system comprises an alarm system for liquid sodium using point and line electric contact sensors and flame photometer based aerosol sensors as well as a fire-fighting system based on the system of channelling liquid sodium into emergency discharge tanks filled with an inert gas, a set of fire extinguishers and other fire fighting material, and measures for the elimination of sodium fire consequences. (J.B.)

  18. Radiation protection system in Azerbaijan Republic

    International Nuclear Information System (INIS)

    Aliyev, L.

    2002-01-01

    land or merge into Caspian See. Is increased also the bring into country of instruments, equipments and other technical means, which work on radioactive sources basic. The numerated facts indicate that is necessary function of good radiation control land protection's system in Azerbaijan (sector radiation's investigations, Radioecology Center NMS of Ministry for Ecology and Natural Recourses the special Plant 'Isotope' and his burring point of radioactive wastes, Civil Defense. Academic organizations and NMS, execute monitoring, control and noticing function by radiation situation. The last two organizations structures, which have been occupied with keeping, transportation, disactivate and burring of radioactive sources and their wastes, which are receiving here from much institutions. The functional activity of special plant 'Isotope' must be reorganized and reconstruct- red the exist PBRW. There is necessity of build of new PBRW, in according with modern technical requirements to the industrial cycle on complete utilization of all radioactive wastes kinds. The monitoring function of radiation situation over all territory of Republic is put on NMS MENR of Azerbaijan. But, for the execution his problems, NMS are necessary new instrumental park (radiometric, dozemetric, spectrometric and etc.) and the dense monitoring network over all territory of Azerbaijan Republic. Co-operation with IAEA will allow improve the quality of radiation protection system of Azerbaijan in shorter periods. (author)

  19. The run permit protection system for GTA

    International Nuclear Information System (INIS)

    Atkins, W.H.; Jones, R.G.

    1992-01-01

    A Run Permit system has been designed for the Ground Test Accelerator (GTA). The system implements mode-dependent software interlocks to ensure proper operation of the accelerator, enabling the ion source extractor and RF systems when proper conditions are met. The system is implemented using the GTA control system; thus all information available to the control system is also available for use in interlock logic. The logic is defined in terms of control system channels, which reflect accelerator parameters such as actuator positions, power supply values, temperatures, etc. A mode switch in the control room selects the accelerator operating mode, for example i njector only . The Run Permit software selects interlock logic as appropriate operating mode. This implementation easily accommodates logic changes as requirements evolve. To ensure reliable operation of a software-based system, a special circuit with a watch-dog timer is employed to produce the system's output signals. The software must periodically address the circuit, or the output signals are forced to a disabled state. For additional protection, there are self-test provisions for detecting and reacting to failures of the control system. (Author) 4 figs., ref

  20. Integral isolation valve systems for loss of coolant accident protection

    Science.gov (United States)

    Kanuch, David J.; DiFilipo, Paul P.

    2018-03-20

    A nuclear reactor includes a nuclear reactor core comprising fissile material disposed in a reactor pressure vessel having vessel penetrations that exclusively carry flow into the nuclear reactor and at least one vessel penetration that carries flow out of the nuclear reactor. An integral isolation valve (IIV) system includes passive IIVs each comprising a check valve built into a forged flange and not including an actuator, and one or more active IIVs each comprising an active valve built into a forged flange and including an actuator. Each vessel penetration exclusively carrying flow into the nuclear reactor is protected by a passive IIV whose forged flange is directly connected to the vessel penetration. Each vessel penetration carrying flow out of the nuclear reactor is protected by an active IIV whose forged flange is directly connected to the vessel penetration. Each active valve may be a normally closed valve.

  1. Radiological protection national system. Basic security rules

    International Nuclear Information System (INIS)

    1981-01-01

    This work has been prepared as the first one of a set of standards and regulations that will be enforced to provide the protection of men and the environment against the undesirable effects of ionizing radiations. It establishes, in the first place, the system of dose limits for the country and the principles of its utilization. It takes into account the CIPR's recommendations in this area and the mentioned frame of reference, it establishes further the necessary restrictions for the application of the limits to the professionally exposed workers, as well as to the isolated members of the public and the population in general. In addition it establishes the general conditions to be met for the implementation of radiological protection, among them, the classification of working areas and working conditions as well as the compulsory periodical medical surveillance. (H.D.N.)

  2. The activities and prospect of planetary protection research in China

    Science.gov (United States)

    Li, Ming

    2016-07-01

    Planetary protection is an important activities and responsibilities for space exploration. In Chinese manned missions, micro-organism research and protection has been developed in Shenzhou-9, Shenzhou-10 and Tiangong-2 missions. In the experiment facility of Lunar Palace-1, the micro-organism pollution and protection/control technology has been studied. In the lunar sample recovery mission and China Mars mission, the planetary protection has become an important issue. This paper introduced the research about planetary protection in China. The planetary protection activities, strategy and procedures have been suggested for future space exploration program to meet the requirement for planetary protection, such as cabin pollution isolation, pollutant detection, and so on.

  3. Radiological protection system in the era of nuclear renaissance expectation for development of radiological protection system

    International Nuclear Information System (INIS)

    Toyomatsu, Hideki

    2008-01-01

    The current radiological protection system, which was established mainly by the ICRP and UNSCEAR, has contributed to the prevention of potential radiological health hazards, and has been a fundamental concept during the development of nuclear energy. Through a detailed discussion regarding the new ICRP recommendations, the world nuclear industry has reached a consensus that the current radiological protection system keeps its integrity in principle although it involves some remaining issues, such as the disposal of radioactive waste. In order to maximize the advantages of nuclear energy while keeping the integrity of radiological protection system, it is essential to address the characteristics of radiation, which is specific to nuclear energy, so that nuclear energy can coexist with other energy sources. The three basic principles of radiological protection (i.e., justification, optimization and dose limits), which were completed in the 1990 recommendations of ICRP, should be retained as the basic concepts for the future radiological protection system in order to maintain the continuity and consistency of the radiological protection system. The radiological protection system can be furthermore developed only by combining the above three principles with best practices extracted from utilities' field experience. The significant reduction of radiation exposures received by members of the public and radiation workers in the field has resulted from the efforts by the world utilities to achieve the optimization. In order to correctly apply the theory to the work practices, it is essential to see how the theory is practically used in the field. Such a process should be also emphasized in the revision work of the IAEA Basic Safety Standards (BSS), which is currently under progress. Integrating the theory in the work practices is the key to the true development of nuclear renaissance, which could lead to the establishment of the nuclear safety regime. (author)

  4. TREAT Reactor Control and Protection System

    International Nuclear Information System (INIS)

    Lipinski, W.C.; Brookshier, W.K.; Burrows, D.R.; Lenkszus, F.R.; McDowell, W.P.

    1985-01-01

    The main control algorithm of the Transient Reactor Test Facility (TREAT) Automatic Reactor Control System (ARCS) resides in Read Only Memory (ROM) and only experiment specific parameters are input via keyboard entry. Prior to executing an experiment, the software and hardware of the control computer is tested by a closed loop real-time simulation. Two computers with parallel processing are used for the reactor simulation and another computer is used for simulation of the control rod system. A monitor computer, used as a redundant diverse reactor protection channel, uses more conservative setpoints and reduces challenges to the Reactor Trip System (RTS). The RTS consists of triplicated hardwired channels with one out of three logic. The RTS is automatically tested by a digital Dedicated Microprocessor Tester (DMT) prior to the execution of an experiment. 6 refs., 5 figs., 1 tab

  5. Fault-tolerant reactor protection system

    International Nuclear Information System (INIS)

    Gaubatz, D.C.

    1997-01-01

    A reactor protection system is disclosed having four divisions, with quad redundant sensors for each scram parameter providing input to four independent microprocessor-based electronic chassis. Each electronic chassis acquires the scram parameter data from its own sensor, digitizes the information, and then transmits the sensor reading to the other three electronic chassis via optical fibers. To increase system availability and reduce false scrams, the reactor protection system employs two levels of voting on a need for reactor scram. The electronic chassis perform software divisional data processing, vote 2/3 with spare based upon information from all four sensors, and send the divisional scram signals to the hardware logic panel, which performs a 2/4 division vote on whether or not to initiate a reactor scram. Each chassis makes a divisional scram decision based on data from all sensors. Each division performs independently of the others (asynchronous operation). All communications between the divisions are asynchronous. Each chassis substitutes its own spare sensor reading in the 2/3 vote if a sensor reading from one of the other chassis is faulty or missing. Therefore the presence of at least two valid sensor readings in excess of a set point is required before terminating the output to the hardware logic of a scram inhibition signal even when one of the four sensors is faulty or when one of the divisions is out of service. 16 figs

  6. Thermal Protection Systems: Past, Present and Future

    Science.gov (United States)

    Johnson, Sylvia M.

    2015-01-01

    Thermal protection materials and systems (TPS) have been critical to fulfilling humankinds desire to explore space. Composite and ceramic materials have enabled the early missions to orbit, the moon, the space station, Mars with robots, and sample return. Crewed missions to Mars are being considered, and this places even more demands on TPS materials. This talk will give some history on the materials used for earth and planetary entry and the demands placed upon such materials. TPS needs for future missions, especially to Mars, will be identified and potential solutions discussed.

  7. Towards an Active Hearing Protection Device for Musicians =

    Science.gov (United States)

    Bernier, Antoine

    Professional musicians are oftentimes exposed to high levels of sound. Prolonged or severe exposure to high sound levels could lead to permanent hearing loss and compromise their career. The logical solution would be to wear hearing protection devices (HPDs) when appropriate. However, perceptual discomfort associated with wearing HPD can discourage their use by musicians. The perceptual discomfort is caused by two detrimental effects: the occlusion effect and the isolation effect. The occlusion effect is often reported as an augmented, unnatural and annoying perception of one's own voice or instrument mechanically coupled to the head when wearing HPDs. The isolation effect is the unnatural sensation of being isolated from a given sound environment and can be caused by wearing HPDs that do not compensate for psychoacoustical factors and therefore alter the wearer's auditory perception. Both effects are highly unfavorable to the musicians' auditory perception and compromise their capacity to perform to the best of their abilities for their audience. They are among the reasons most often reported by musicians to decide not to wear HPDs. This master's project presents the concept and first prototype of an active HPD for musicians that aims at solving the detrimental effects while protecting the musician's hearing. A solution for the occlusion effect is presented in the form of an earplug complemented with in-ear active noise control. Practical design issues and required trade-off are analyzed through a literature review and the implementation and characterization of an active occlusion effect reduction system, allowing reduction of the occlusion effect between 8.5 and 12 dB at 250 Hz. A solution for the isolation effect is presented in the form of an earplug complemented with digital signal processing capabilities. Factors that may cause the isolation effect are identified through a literature review and corresponding algorithms that aim at re-establishing the

  8. ICI system for protecting underwater structures

    Energy Technology Data Exchange (ETDEWEB)

    1977-10-14

    The new ICI Offshore product consists of polypropylene fibers about 4.4 m long, and with a density lower than that of sea water and thus a good buoyancy coefficient. Bundles of the fibers are passed through a braided mat of polyester, ''Paraweb'', which is weighted in accordance with the density of the entire system. The system is installed at the foot of platform legs and axially along pipelines to prevent scouring by ocean currents. The system has been installed in 144.8 m of water along the pipeline linking the Piper field to the Flotta terminal in the Orkney Islands. By reducing the velocity of the marine currents, the system causes sand and other material to be deposited along the fibers, forming a protective ''talus'' cone at first, then completely covering the structure. A sizable sand deposit had accumulated along the test segment of the pipeline less than one month after installation of the system. Use of the system on the Ekofisk-Emden gas pipeline where it is uncovered in the Danish North Sea sector is proposed.

  9. Privacy protection schemes for fingerprint recognition systems

    Science.gov (United States)

    Marasco, Emanuela; Cukic, Bojan

    2015-05-01

    The deployment of fingerprint recognition systems has always raised concerns related to personal privacy. A fingerprint is permanently associated with an individual and, generally, it cannot be reset if compromised in one application. Given that fingerprints are not a secret, potential misuses besides personal recognition represent privacy threats and may lead to public distrust. Privacy mechanisms control access to personal information and limit the likelihood of intrusions. In this paper, image- and feature-level schemes for privacy protection in fingerprint recognition systems are reviewed. Storing only key features of a biometric signature can reduce the likelihood of biometric data being used for unintended purposes. In biometric cryptosystems and biometric-based key release, the biometric component verifies the identity of the user, while the cryptographic key protects the communication channel. Transformation-based approaches only a transformed version of the original biometric signature is stored. Different applications can use different transforms. Matching is performed in the transformed domain which enable the preservation of low error rates. Since such templates do not reveal information about individuals, they are referred to as cancelable templates. A compromised template can be re-issued using a different transform. At image-level, de-identification schemes can remove identifiers disclosed for objectives unrelated to the original purpose, while permitting other authorized uses of personal information. Fingerprint images can be de-identified by, for example, mixing fingerprints or removing gender signature. In both cases, degradation of matching performance is minimized.

  10. Neutronic control instrumentation of protection systems

    International Nuclear Information System (INIS)

    Furet, J.

    1977-01-01

    The aims of neutronic control instrumentation are briefly recalled and the present status of materials research and development is presented. As for the out-of-pile instrumentation, emphasis is put on the reliability and efficiency of the detectors and the new solutions of electric signal processing. The possible reactivity measurements at rest are examined. As for in-pile instrumentation results relating to mobile detectors of the type of miniaturized fission chambers are presented. The radiation tests on course of development for several years in the working conditions of neutron self-powdered detectors are analyzed so as to show that their use as built-in in-core instrumentation is to be envisaged at short term. Basic options inherent to the 'Nuclear Safety' philosophy that define the protection system are recalled. A definition and a justification of the performance testing of the instrumentation at rest and in-service are then derived. Some new solutions are envisaged for processing the digital data obtained from the various sensors . A quality control of the materials setting conditions (especially electric noise) ensures a high reliability and availability of the materials involved in the neutron control and the protection system in working conditions [fr

  11. 3D Multifunctional Ablative Thermal Protection System

    Science.gov (United States)

    Feldman, Jay; Venkatapathy, Ethiraj; Wilkinson, Curt; Mercer, Ken

    2015-01-01

    NASA is developing the Orion spacecraft to carry astronauts farther into the solar system than ever before, with human exploration of Mars as its ultimate goal. One of the technologies required to enable this advanced, Apollo-shaped capsule is a 3-dimensional quartz fiber composite for the vehicle's compression pad. During its mission, the compression pad serves first as a structural component and later as an ablative heat shield, partially consumed on Earth re-entry. This presentation will summarize the development of a new 3D quartz cyanate ester composite material, 3-Dimensional Multifunctional Ablative Thermal Protection System (3D-MAT), designed to meet the mission requirements for the Orion compression pad. Manufacturing development, aerothermal (arc-jet) testing, structural performance, and the overall status of material development for the 2018 EM-1 flight test will be discussed.

  12. Food protection activities of the Pan American Health Organization.

    Science.gov (United States)

    1994-03-01

    One of the most widespread health problems in the Caribbean and Latin America is contaminated food and foodborne illness. The Pan American Health Organization (PAHO) has been a major force in activities to strengthen food protection. The program within the regional Program of Technical Cooperation is administered by the Veterinary Public Health program and under the guidance of the Pan American Institute for Food protection and Zoonoses in Buenos Aires, Argentina. A food action plan for 1986-90 was established at the 1986 Pan American Sanitary Conference, and extended to cover 1991-95. Program activities during the 1990s covered cholera, epidemiologic surveillance, street food vendors, shellfish poisoning, meat, national programs, information systems, air catering, food irradiation, and tourism. The action plan for 1991-95 promoted greater political support and cooperation within and between related sectors and institutions, management, and education. The aims were to organize national integrated programs, to strengthen laboratory services, to strengthen inspection services, to establish epidemiologic surveillance systems, and to promote food protection through community participation. Program activities included the initiatives of the Veterinary Public Health Program in 1991 to distribute literature on the transmission of cholera by foods. Studies were conducted in Bolivia, Colombia, and Peru on food contamination. Microbiologists received training on standard methods for detecting Vibrio cholerae in foods. A working group of experts from 10 countries examined the issues and produced a guide for investigating the incidence of foodborne disease. PAHO has contributed to the formation of an Inter-American Network for Epidemiologic Surveillance of Foodborne Diseases. PAHO has worked to improve hygienic practices among street food vendors. Seminars on paralytic shellfish poisoning were conducted in 1990; the outcome was a network working to strengthen national

  13. Extensions and renovations of reactor protection systems

    International Nuclear Information System (INIS)

    Hellmerichs, K.

    1985-01-01

    Increase of requirements by the authorities as to the design of reactor protection systems affected in the last years not only plans being under construction, but also resulted in partly spacious extensions and renovations. While working on the extensions and renovations a lot of problems arose: far-reaching performance of newest guidelines and rules in spite of old plant concepts; partly higher degree of redundancy requirements of the new systems in contrast to the present systems; use of present safeguard systems for new accident countermeasures; designation of priorities between present and new functions, especially in view of fault behaviour of present systems; adaptation of the new I and C equipment to the present signalisation-, operation- and information-arrangements under consideration of the present operational philosophy; spatial incorporation of new equipments; construction as to time without expanding of the planned refuelling phases. Because the KWU has planned and constructed such alterations in nearly 10 plants a lot of experience has been gathered. (author)

  14. Protection of the wilderness and aesthetic values of Antarctica: Geographical Information Systems (GIS) as a tool

    Science.gov (United States)

    Rupert Summerson; Tina Tin

    2011-01-01

    Antarctica is designated by the Antarctic Treaty System as a "natural reserve devoted to peace and science" (http://www.ats.aq/index_e.htm). Multiple, and sometimes conflicting, values are protected. In a place where wilderness protection and certain forms of human activity are both prized, a discussion of the protection of the Antarctic wilderness...

  15. 46 CFR 154.1110 - Areas protected by system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Areas protected by system. 154.1110 Section 154.1110... Firefighting § 154.1110 Areas protected by system. Each water spray system must protect: (a) All cargo tank... valves essential to cargo flow; (f) Each boundary facing the cargo area of each superstructure that...

  16. 46 CFR 153.460 - Fire protection systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Fire protection systems. 153.460 Section 153.460... Requirements for Flammable Or Combustible Cargoes § 153.460 Fire protection systems. Each self-propelled ship... protection system listed beside the cargo in Table 1 and described in the footnotes to Table 1. (b) The...

  17. The radiation protection programme activities of the World Health Organization

    International Nuclear Information System (INIS)

    Komarov, E.; Suess, M.J.

    1980-01-01

    The radiation protection activities of the World Health Organization are reviewed. They include studies of radiation protection standards and guidelines, and public health aspects of nuclear power. WHO also provides member states with world data on radioactivity in air, water and food, and assessments of population exposure and health effects. (H.K.)

  18. Does physical activity protect against drug abuse vulnerability?

    Science.gov (United States)

    Bardo, Michael T; Compton, Wilson M

    2015-08-01

    The current review examined recent literature to determine our state of knowledge about the potential ability of physical activity serve as a protectant against drug abuse vulnerability. Both preclinical and clinical studies were examined using either associational or random assignment study designs. In addition to examining drug use as an outcome variable, the potential neural mediators linking physical activity and drug abuse vulnerability were examined. Several important conclusions may be drawn. First, the preclinical evidence is solid in showing that physical activity in various forms is able to serve as both a preventive and treatment intervention that reduces drug use, although voluntary alcohol drinking appears to be an exception to this conclusion. Second, the clinical evidence provides some evidence, albeit mixed, to suggest a beneficial effect of physical activity on tobacco dependent individuals. In contrast, there exists only circumstantial evidence that physical activity may reduce use of drugs other than nicotine, and there is essentially no solid information from random control studies to know if physical activity may prevent initiation of problem use. Finally, both preclinical and clinical evidence shows that various brain systems are altered by physical activity, with the medial prefrontal cortex (mPFC) serving as one potential node that may mediate the putative link between physical activity and drug abuse vulnerability. It is concluded that novel neurobehavioral approaches taking advantage of novel techniques for assessing the physiological impact of physical activity are needed and can be used to inform the longitudinal random control studies that will answer definitively the question posed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Digital signal processing in power system protection and control

    CERN Document Server

    Rebizant, Waldemar; Wiszniewski, Andrzej

    2011-01-01

    Digital Signal Processing in Power System Protection and Control bridges the gap between the theory of protection and control and the practical applications of protection equipment. Understanding how protection functions is crucial not only for equipment developers and manufacturers, but also for their users who need to install, set and operate the protection devices in an appropriate manner. After introductory chapters related to protection technology and functions, Digital Signal Processing in Power System Protection and Control presents the digital algorithms for signal filtering, followed

  20. An Evolved System of Radiological Protection

    International Nuclear Information System (INIS)

    Kaneko, M.

    2004-01-01

    The current system of radiological protection based on the Linear No-Threshold (LNT) hypothesis has greatly contributed to the minimization of doses received by workers and members of the public. However, it has brought about r adiophobia a mong people and waste of resources due to over-regulation, because the LNT implies that radiation is harmful no matter how small the dose is. The author reviewed the results of research on health effects of radiation including major epidemiological studies on radiation workers and found no clear evidence of deleterious health effects from radiation exposures below the current maximum dose limits (50 mSv/y for workers and 5 mSv/y for members of the public), which have been adopted worldwide in the second half of the 20th century. Now that the existence of bio-defensive mechanisms such as DNA repair, apoptosis and adaptive response are well recognized, the linearity assumption cannot be said to be s cientific . Evidences increasingly imply that there are threshold effects in risk of radiation. A concept of practical thresholds or virtually safe doses will have to be introduced into the new system of radiological protection in order to resolve the low dose issues. Practical thresholds may be defined as dose levels below which induction of detectable radiogenic cancers or hereditary effects are not expected. If any workers and members of the public do not gain benefits from being exposed, excepting intentional irradiation for medical purposes, their radiation exposures should be kept below practical thresholds. On the assumption that the current dose limits are below practical thresholds and with no radiation detriments, there is no need of justification and optimization (ALARA) principles for occupational and public exposures. Then the ethical issue of justification to allow benefit to society to offset radiation detriments to individuals can be resolved. And also the ethical issue of optimization to exchange health or safety for

  1. Diversity in computerized reactor protection systems

    International Nuclear Information System (INIS)

    Fischer, H.D.; Piel, L.

    1999-01-01

    Based on engineering judgement, the most important measures to increase the independency of redundant trains of a computerized safety instrumentation and control system (I and C) in a nuclear power plant are evaluated with respect to practical applications. This paper will contribute to an objective discussion on the necessary and justifiable arrangement of diversity in a computerized safety I and C system. Important conclusions are: - (i) diverse equipment may be used to control dependent failures only if measures necessary for designing, licensing, and operating a computerized safety I and C system homogeneous in equipment are neither technically nor economically feasible; - (ii) the considerable large operating experience in France with a non-diverse equipment digital reactor protection system does not call for equipment diversity. Although there are no generally accepted methods, the licensing authority is still required to take into account dependent failures in a probabilistic safety analysis; - (ii) the frequency of postulated initiating events implies which I and C functionality should be implemented on diverse equipment. Using non-safety I and C equipment in addition to safety I and C equipment is attractive because its necessary unavailability to control an initiating event in teamwork with the safety I and C equipment is estimated to range from 0.01 to 0.1. This can be achieved by operational experience

  2. Protecting HVAC systems from bio-terrorism.

    Science.gov (United States)

    Arterburn, Tom

    2003-01-01

    The FBI, in the wake of the September 11 attacks, issued an advisory to state and local law enforcement authorities and the public asking to remain especially alert to any unusual activities around ventilation systems. It noted that while the Bureau possessed no specific threats regarding the release of toxic chemicals into air handling systems, building owners and managers should be well-aware of the potential for contamination of such systems. This article presents recommendations of air-handling experts and associations for operators to consider.

  3. Integration of the environment into the system of radiation protection

    International Nuclear Information System (INIS)

    Higley, K.

    2018-01-01

    In 2005 the International Commission on Radiological Protection (ICRP) embarked on an effort to ensure that the system for environmental radiological protection would be reconcilable with that for radiological protection of man, and with the approaches used for protection of the environment from other potential hazards

  4. The influence of increased cross-linker chain length in thermosensitive microspheres on potential sun-protection activity

    OpenAIRE

    Musiał, Witold; Kokol, Vanja; Vončina, Bojana

    2012-01-01

    The sun protection should involve substances with protecting activity against both UVB and UVA radiation. In this research the evaluation of thermosensitive microspheres as potential molecules for sunscreen formulations was approached, using modified Boots star rating system. The microspheres, thermosensitive N-isopropylacrylamide derivatives, have potential protecting activity against UV radiation. The MX and DX microspheres, with ethylene glycol dimethacrylate and diethylene glycol dimethac...

  5. Reliable Software Development for Machine Protection Systems

    CERN Document Server

    Anderson, D; Dragu, M; Fuchsberger, K; Garnier, JC; Gorzawski, AA; Koza, M; Krol, K; Misiowiec, K; Stamos, K; Zerlauth, M

    2014-01-01

    The Controls software for the Large Hadron Collider (LHC) at CERN, with more than 150 millions lines of code, resides amongst the largest known code bases in the world1. Industry has been applying Agile software engineering techniques for more than two decades now, and the advantages of these techniques can no longer be ignored to manage the code base for large projects within the accelerator community. Furthermore, CERN is a particular environment due to the high personnel turnover and manpower limitations, where applying Agile processes can improve both, the codebase management as well as its quality. This paper presents the successful application of the Agile software development process Scrum for machine protection systems at CERN, the quality standards and infrastructure introduced together with the Agile process as well as the challenges encountered to adapt it to the CERN environment.

  6. Overload protection system for power inverter

    Science.gov (United States)

    Nagano, S. (Inventor)

    1977-01-01

    An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

  7. The international safeguards system and physical protection

    International Nuclear Information System (INIS)

    Canty, M.J.; Lauppe, W.D.; Richter, B.; Stein, G.

    1990-02-01

    The report summarizes and explains facts and aspects of the IAEA safeguards performed within the framework of the Non-Proliferation Treaty, and shows perspectives to be discussed by the NPT Review Conferences in 1990 and 1995. The technical background of potential misuse of nuclear materials for military purposes is explained in connection with the physical protection regime of the international safeguards, referring to recent developments for improvement of technical measures for material containment and surveillance. Most attention is given to the peaceful uses of nuclear energy and their surveillance by the IAEA safeguards, including such new technologies and applications as controlled nuclear fusion, laser techniques for uranium enrichment, and particle accelerators. The report's concluding analyses of the current situation show potentials for improvement and desirable or necessary consequences to be drawn for the international safeguards system, also taking into account recent discussions on the parliamentary level. (orig./HP) [de

  8. Establishing an Information Security System related to Physical Protection

    International Nuclear Information System (INIS)

    Jang, Sung Soon; Yoo, Ho Sik

    2009-01-01

    A physical protection system (PPS) integrates people, procedures and equipment for the protection of assets or facilities against theft, sabotage or other malevolent attacks. In the physical protection field, it is important the maintain confidentiality of PPS related information, such as the alarm system layout, detailed maps of buildings, and guard schedules. In this abstract, we suggest establishing a methodology for an information security system. The first step in this methodology is to determine the information to protect and possible adversaries. Next, system designers should draw all possible paths to the information and arrange appropriate protection elements. Finally he/she should analyze and upgrade their information security system

  9. Machine protection system algorithm compiler and simulator

    International Nuclear Information System (INIS)

    White, G.R.; Sherwin, G.

    1993-01-01

    The Machine Protection System (MPS) component of the SLC's beam selection system, in which integrated current is continuously monitored and limited to safe levels through careful selection and feedback of the beam repetition rate, is described elsewhere in these proceedings. The novel decision making mechanism by which that system can evaluate open-quotes safe levelsclose quotes, and choose an appropriate repetition rate in real-time, is described here. The algorithm that this mechanism uses to make its decision is written in test files and expressed in states of the accelerator and its devices, one file per accelerator region. Before being used, a file is open-quotes compiledclose quotes to a binary format which can be easily processed as a forward-chaining decision tree. It is processed by distributed microcomputers local to the accelerator regions. A parent algorithm evaluates all results, and reports directly to the beam control microprocessor. Operators can test new algorithms, or changes they make to them, with an online graphical MPS simulator

  10. Radiation protection activities around the CERN accelerators

    International Nuclear Information System (INIS)

    Silari, M.

    1997-01-01

    The staff of the Survey Section of Radiation Protection (RP) working around the CERN accelerators were as usual very busy. The LEP2 programme is now fully on its way, with the installation of additional superconducting RF cavities carried out during both the winter and summer shutdowns. The LEP energy per beam was thus increased to 80.5 GeV in summer and to 86 GeV in autumn. ACOL and LEAR ended their operational life on 19 December producing, for the last time, antiprotons for the experiments in the South Hall; all experiments will be dismantled in 1997. This programme will be partly replaced by the future Antiproton Decelerator, which was approved by the Research Board in November. Several experiments also came to their end in the North and West Experimental Areas of the SPS. NA44 (in EHN1) and NA47 (in EHN2) ended this year. All experiments installed in beam lines HI, H3, XI and X3 in the West Area also terminated, as these beam lines will be dismantled in the course of 1997 to make room for test facilities for the LHC. Several modifications in the West and North Experimental Areas have already been undertaken at the end of the year and will be continued in 1997. Some equipment installed in the West Area will be moved to the North Area. In addition to routine work, several measurements of synchrotron radiation were made in LEP for the two new energy levels reached in 1996. A number of dedicated measurements were also undertaken in EHN1 (North Area) at the end of the year, during the lead-ion run which closed the physics period. A detailed assessment of releases of radioactivity from the ISOLDE facility was also made

  11. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  12. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  13. 14 CFR 23.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 23.954... Fuel System § 23.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor within the system by— (a) Direct lightning strikes to areas having a...

  14. Regional and national radiation protection activities in Egypt

    International Nuclear Information System (INIS)

    Gomaa, M.A.M.

    2008-01-01

    Radiation protection activities in Egypt go back to 1957 where the Egyptian Atomic Energy Commission (EAEC) Law was issued. Radiation protection and civil defense department was one of EAEC eighth departments. Ionizing radiation law was issued in 1960 and its executive regulation in 1962. The main aim of the present work is to through some light on the current radiation protection activities in Egypt. This includes not only the role of governmental organizations but also to the non governmental organizations. Currently a new Nuclear Safety law is understudy. Regional activities such as holding the second all African IRPA regional radiation protection congress which was held in April 2007 and national training and workshops are held regularly through EAEA, AAEA and MERRCAC. (author)

  15. Electrical Power Systems Protection and Interdependencies with ICT

    OpenAIRE

    Milis, George; Kyriakides, Elias; Hadjiantonis, Antonis

    2017-01-01

    The present chapter discusses the issue of protection of the electrical power systems, addressing all dimensions, from the need of protection to the identified faults and disturbances to the available protection schemes and further considerations, also looking at the challenges brought by recognizing the interdependent nature of the today’s electrical power systems.

  16. Modern tools to evaluate and optimize fire protection systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Hasegawa, H.K.

    1980-01-01

    Modern techniques, such as fault tree analysis, can be used to obtain engineering descriptions of specific fire protection systems. The analysis allows establishment of an optimum level of fire protection, and evaluates the level of protection provided by various systems. A prime example: the application to fusion energy experiments

  17. Safety aspect of digital reactor protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Zen-Ichi

    1998-01-01

    It was early in 1980's that the digital controllers were first applied to nuclear power plant in japan. After that, their application area had been expanding gradually, reaching to the overall integrated digital system including the safety system in Kashiwazaki-Kariwa units 6 and 7. The software for computer-based systems has been produced using the graphical language ''POL'' in Japanese nuclear power plants. It is the fundamental principle that the reliability of the software should be assured through the properly managed quality assurance. The POL-based system is fitted to this principle. In applying POL-based systems to safety system, the MITI, Ministry of International Trade and Industry, identified the licensing issues as the regulatory body, while the utilities had developed the digital technology feasible to the safety application. Through the activities, a specific industrial design guide for the software important to safety was established and the adequacy of the technology was certified through the demonstration tests of the integrated system. In the safety examination of the digital reactor protection system of K-6/7, the application of POL were approved. The POL-based systems in nuclear power plants were successful design and production process of the POL-based systems. This paper describes the activities in licensing and maintaining the computer-based systems by the utilities and manufacturers as well as the MITI. (author)

  18. Effect of Remote Back-Up Protection System Failure on the Optimum Routine Test Time Interval of Power System Protection

    Directory of Open Access Journals (Sweden)

    Y Damchi

    2013-12-01

    Full Text Available Appropriate operation of protection system is one of the effective factors to have a desirable reliability in power systems, which vitally needs routine test of protection system. Precise determination of optimum routine test time interval (ORTTI plays a vital role in predicting the maintenance costs of protection system. In the most previous studies, ORTTI has been determined while remote back-up protection system was considered fully reliable. This assumption is not exactly correct since remote back-up protection system may operate incorrectly or fail to operate, the same as the primary protection system. Therefore, in order to determine the ORTTI, an extended Markov model is proposed in this paper considering failure probability for remote back-up protection system. In the proposed Markov model of the protection systems, monitoring facility is taken into account. Moreover, it is assumed that the primary and back-up protection systems are maintained simultaneously. Results show that the effect of remote back-up protection system failures on the reliability indices and optimum routine test intervals of protection system is considerable.

  19. Active lifestyle protects against incident low back pain in seniors

    DEFF Research Database (Denmark)

    Hartvigsen, Jan; Christensen, Kaare

    2007-01-01

    STUDY DESIGN: Prospective cohort study of twins. OBJECTIVES: To investigate associations between physical activity, physical function, and incident low back pain (LBP) in an elderly population. SUMMARY OF BACKGROUND DATA: The relationship between an active lifestyle and LBP in seniors is unknown...... to be an important factor affecting whether participants remained engaged in strenuous physical activity at baseline and follow-up or vice versa. CONCLUSIONS: Strenuous physical activity at least once a week is protective for incident LBP in seniors....

  20. Rack Protection Monitor - A Simple System

    International Nuclear Information System (INIS)

    Orr, S.

    1997-12-01

    The Rack Protection Monitor is a simple, fail-safe device to monitor smoke, temperature and ventilation sensors. It accepts inputs from redundant sensors and has a hardwired algorithm to prevent nuisance power trips due to random sensor failures. When a sensor is triggered the Rack Protection Monitor latches and annunicates the alarm. If another sensor is triggered, the Rack Protection Monitor locally shuts down the power to the relay rack and sends alarm to central control

  1. 14 CFR 25.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 25.954...

  2. 14 CFR 27.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 27.954...

  3. 14 CFR 29.954 - Fuel system lightning protection.

    Science.gov (United States)

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.954 Fuel system lightning protection. The fuel system must be designed and arranged to prevent the ignition of fuel vapor... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system lightning protection. 29.954...

  4. Evaluation of several corrosion protective coating systems on aluminum

    Science.gov (United States)

    Higgins, R. H.

    1981-01-01

    A study of several protective coating systems for use on aluminum in seawater/seacoast environments was conducted to review the developments made on protective coatings since early in the Space Shuttle program and to perform comparative studies on these coatings to determine their effectiveness for providing corrosion protection during exposure to seawater/seacoast environments. Panels of 2219-T87 aluminum were coated with 21 different systems and exposed to a 5 percent salt spray for 4000 hr. Application properties, adhesion measurements, heat resistance and corrosion protection were evaluated. For comparative studies, the presently specified Bostik epoxy system used on the SRB structures was included. Results of these tests indicate four systems with outstanding performance and four additional systems with protection almost as good. These systems are based on a chromated pretreatment, a chromate epoxy primer, and a polyurethane topcoat. Consideration for one of these systems should be included for those applications where superior corrosion protection for aluminum surfaces is required.

  5. Specific features of modern voice protection systems

    Directory of Open Access Journals (Sweden)

    Roman A. Ustinov

    2017-11-01

    Full Text Available Nowadays, speech technologies are among the most vibrant sectors of the world’s economy. Of high importance is the problem of ensuring the security of speech information (SI. Here we discuss SI protection systems within a modern communication model. The model is multimodal, multithreaded, and implies a large number of subscribers interacting via several communication lines. With this in mind, we perform a detailed analysis of threats to the confidentiality, integrity and accessibility of SI. Existing methods of counteraction against these threats are discussed, and shown to be insufficient to ensure the safety of voice messages (VM in full. Mean while, there are new threats to the integrity and accessibility of SI, the solutions for which are either do not exist, or only being developed. We propose our original approach to counter these threats. Steganography methods are the most promising for ensuring the integrity of the VM.  In particular, using audiomarkers allows one to reliably trace speaker’sidentity throughout the entire communication session. In order to counter the threats to SI availability due to the capacity of the communication channel and the limited volumes of VM data storage, it is necessary to improve existing adaptive speech compression algorithms, along with developing new ones. Furthermore, such algorithms must keep the specified level of speech intelligibility.

  6. Advanced materials for thermal protection system

    Science.gov (United States)

    Heng, Sangvavann; Sherman, Andrew J.

    1996-03-01

    Reticulated open-cell ceramic foams (both vitreous carbon and silicon carbide) and ceramic composites (SiC-based, both monolithic and fiber-reinforced) were evaluated as candidate materials for use in a heat shield sandwich panel design as an advanced thermal protection system (TPS) for unmanned single-use hypersonic reentry vehicles. These materials were fabricated by chemical vapor deposition/infiltration (CVD/CVI) and evaluated extensively for their mechanical, thermal, and erosion/ablation performance. In the TPS, the ceramic foams were used as a structural core providing thermal insulation and mechanical load distribution, while the ceramic composites were used as facesheets providing resistance to aerodynamic, shear, and erosive forces. Tensile, compressive, and shear strength, elastic and shear modulus, fracture toughness, Poisson's ratio, and thermal conductivity were measured for the ceramic foams, while arcjet testing was conducted on the ceramic composites at heat flux levels up to 5.90 MW/m2 (520 Btu/ft2ṡsec). Two prototype test articles were fabricated and subjected to arcjet testing at heat flux levels of 1.70-3.40 MW/m2 (150-300 Btu/ft2ṡsec) under simulated reentry trajectories.

  7. Protected areas system planning and monitoring

    NARCIS (Netherlands)

    Vreugdenhil, D.

    2003-01-01

    The Vth World Parks Congress to be held in Durban, South Africa, September 8-17, 2003 will evaluate progress in protected areas conservation and stipulate strategic policies for the coming decade. Most countries of the world have at least a collection of protected areas, and have signed the

  8. Planetary Protection Considerations in EVA System Design

    Science.gov (United States)

    Eppler, Dean B.; Kosmo, Joseph J.

    2011-01-01

    very little expression of these anomalies. hardware from the human-occupied area may limit (although not likely eliminate) external materials in the human habitat. Definition of design-to requirements is critical to understanding technical feasibility and costs. The definition of Planetary Protection needs in relation to EVA mission and system element development cost impacts should be considered and interpreted in terms of Plausible Protection criteria. Since EVA operations will have the most direct physical interaction with the Martian surface, PP needs should be considered in the terms of mitigating hardware and operations impacts and costs.

  9. Decentralized Adaptive Overcurrent Protection for Medium Voltage Maritime Power Systems

    DEFF Research Database (Denmark)

    Ciontea, Catalin-Iosif; Bak, Claus Leth; Blaabjerg, Frede

    2016-01-01

    the entire electrical network and changes the relay settings accordingly, but this approach is not adequate for the maritime power systems. This paper propose a decentralized adaptive protection method, where each protection relay is able to identify by itself the network status without the need of a central...... control unit. The new adaptive protection method is based on communication between the overcurrent relays and the equipment that could affect the protection system, such as circuit breakers and generators. Using PSCAD, the proposed method is implemented in a test medium voltage maritime power system......More and more maritime applications as marine vessels and offshore platforms need an adaptive protection power system. However, the adaptive protection is yet to be implemented in the maritime sector. Usually, the adaptive protection implies the existence of a central control unit that monitors...

  10. Comparison, with regard to safety, between a hard-wired reactor protection system and a computerized protection system. Pt. 1

    International Nuclear Information System (INIS)

    Buettner, W.E.

    1976-07-01

    The study compares a conventional hard-wired dynamic reactor protection system with a computerized protection system. In the comparison, only the unequivocally safety-oriented protection actions are considered. In the first part, the different structures of both systems and the method of verification for their functional safety will be described. In the second part, the mean unavailability in case of demand for both systems under defined conditions will be determined. (orig.) [de

  11. Protective relaying of power systems using mathematical morphology

    CERN Document Server

    Wu, QH; Ji, TY

    2009-01-01

    Discusses the development of novel protective relaying algorithms, using Mathematical Morphology (MM). This book introduces the fundamental principles of MM, and brings together the applications of MM to develop different protective relaying algorithms for the protection of a variety of power system components.

  12. Advanced nuclear control and protection system ANCAP-80

    International Nuclear Information System (INIS)

    Asai, Takashi; Okano, Michihiko; Ishibashi, Kengo; Hasegawa, Masakoto; Fukuda, Hiroyoshi; Hosomichi, Renichi.

    1983-01-01

    Advanced reactor protection systems were developed to improve operational reliability and availability and to ease the burden of operators of Mitsubishi PWR Nuclear Power Stations. (Called ANCAP-80; Advanced Nuclear Control And Protection System) For the PWR plants now being planned and in future plans, Mitsubishi will adopt these systems with the following functional features; (1) Four channel protection logic, (2) Automatic bypass logic, (3) Automatic test provision, (4) Optical isolators. (author)

  13. 5 CFR 551.541 - Employees engaged in fire protection activities or law enforcement activities.

    Science.gov (United States)

    2010-01-01

    ... activities or law enforcement activities. 551.541 Section 551.541 Administrative Personnel OFFICE OF... activities or law enforcement activities. (a) An employee engaged in fire protection activities or law enforcement activities (as described in §§ 551.215 and 551.216, respectively) who receives compensation for...

  14. The evolution of the system of radiological protection: the programme of the Nea committee on radiation protection and public health

    International Nuclear Information System (INIS)

    Mundigl, S.

    2004-01-01

    included a very active CRPPH programme to develop ideas and suggestions that the ICRP can take into account in its work, and the CRPPH has become an active partner with the ICRP to provide the views of regulators and experts from the NEA 28 member countries. The current programme of the CRPPH comprises four major topics: The evolution of the system of radiological protection, the issue of stakeholder involvement, international nuclear emergency preparedness and management, and occupational exposure management including the ISOE Asian Technical Centre in Tokyo. All four topics enjoy the strong involvement of Asian specialists. (author)

  15. StreamNet Query System: Protected Areas

    Data.gov (United States)

    Pacific States Marine Fisheries Commission — Beginning in 1983, the Northwest Power Planning Council (Council) directed extensive studies of existing habitat and has analyzed alternative means of protection. In...

  16. Distributed Computations Environment Protection Using Artificial Immune Systems

    Directory of Open Access Journals (Sweden)

    A. V. Moiseev

    2011-12-01

    Full Text Available In this article the authors describe possibility of artificial immune systems applying for distributed computations environment protection from definite types of malicious impacts.

  17. Salicylic Acid Alleviates the Adverse Effects of Salt Stress on Dianthus superbus (Caryophyllaceae) by Activating Photosynthesis, Protecting Morphological Structure, and Enhancing the Antioxidant System

    Science.gov (United States)

    Ma, Xiaohua; Zheng, Jian; Zhang, Xule; Hu, Qingdi; Qian, Renjuan

    2017-01-01

    Salt stress critically affects the physiological processes and morphological structure of plants, resulting in reduced plant growth. Salicylic acid (SA) is an important signal molecule that mitigates the adverse effects of salt stress on plants. Large pink Dianthus superbus L. (Caryophyllaceae) usually exhibit salt-tolerant traits under natural conditions. To further clarify the salt-tolerance level of D. superbus and the regulating mechanism of exogenous SA on the growth of D. superbus under different salt stresses, we conducted a pot experiment to examine the biomass, photosynthetic parameters, stomatal structure, chloroplast ultrastructure, reactive oxygen species (ROS) concentrations, and antioxidant activities of D. superbus young shoots under 0.3, 0.6, and 0.9% NaCl conditions, with and without 0.5 mM SA. D. superbus exhibited reduced growth rate, decreased net photosynthetic rate (Pn), increased relative electric conductivity (REC) and malondialdehyde (MDA) contents, and poorly developed stomata and chloroplasts under 0.6 and 0.9% salt stress. However, exogenously SA effectively improved the growth, photosynthesis, antioxidant enzyme activity, and stoma and chloroplast development of D. superbus. However, when the plants were grown under severe salt stress (0.9% NaCl condition), there was no significant difference in the plant growth and physiological responses between SA-treated and non-SA-treated plants. Therefore, our research suggests that exogenous SA can effectively counteract the adverse effect of moderate salt stress on D. superbus growth and development. PMID:28484476

  18. Salicylic Acid Alleviates the Adverse Effects of Salt Stress on Dianthus superbus (Caryophyllaceae by Activating Photosynthesis, Protecting Morphological Structure, and Enhancing the Antioxidant System

    Directory of Open Access Journals (Sweden)

    Xiaohua Ma

    2017-04-01

    Full Text Available Salt stress critically affects the physiological processes and morphological structure of plants, resulting in reduced plant growth. Salicylic acid (SA is an important signal molecule that mitigates the adverse effects of salt stress on plants. Large pink Dianthus superbus L. (Caryophyllaceae usually exhibit salt-tolerant traits under natural conditions. To further clarify the salt-tolerance level of D. superbus and the regulating mechanism of exogenous SA on the growth of D. superbus under different salt stresses, we conducted a pot experiment to examine the biomass, photosynthetic parameters, stomatal structure, chloroplast ultrastructure, reactive oxygen species (ROS concentrations, and antioxidant activities of D. superbus young shoots under 0.3, 0.6, and 0.9% NaCl conditions, with and without 0.5 mM SA. D. superbus exhibited reduced growth rate, decreased net photosynthetic rate (Pn, increased relative electric conductivity (REC and malondialdehyde (MDA contents, and poorly developed stomata and chloroplasts under 0.6 and 0.9% salt stress. However, exogenously SA effectively improved the growth, photosynthesis, antioxidant enzyme activity, and stoma and chloroplast development of D. superbus. However, when the plants were grown under severe salt stress (0.9% NaCl condition, there was no significant difference in the plant growth and physiological responses between SA-treated and non-SA-treated plants. Therefore, our research suggests that exogenous SA can effectively counteract the adverse effect of moderate salt stress on D. superbus growth and development.

  19. Protective, curative and eradicative activities of fungicides against grapevine rust

    Directory of Open Access Journals (Sweden)

    Francislene Angelotti

    2014-01-01

    Full Text Available The protective, eradicative and curative activities of the fungicides azoxystrobin, tebuconazole, pyraclostrobin+metiram, and ciproconazole against grapevine rust, were determined in greenhouse. To evaluate the protective activity, leaves of potted ´Niagara´ (Vitis labrusca vines were artificially inoculated with an urediniospore suspension of Phakopsora euvitis four, eight or forteen days after fungicidal spray; and to evaluate the curative and eradicative activities, leaves were sprayed with fungicides two, four or eight days after inoculation. Disease severity was assessed 14 days after each inoculation. All tested fungicides present excellent preventive activity against grapevine rust; however, tebuconazole and ciproconazole provide better curative activity than azoxystrobin and pyraclostrobin+metiram. It was observed also that all tested fungicides significantly reduced the germination of urediniospore produced on sprayed leaves.

  20. High-Level System Change: Protecting Business and Society

    Directory of Open Access Journals (Sweden)

    Frank Dixon

    2017-10-01

    Full Text Available Over the past 15 years, sustainability has become mainstream in the corporate and financial sectors. But environmental and social conditions are declining rapidly in many regions. Nearly all corporate and financial sector sustainability strategies are focused on company-level activities, such as unilaterally mitigating negative environmental and social impacts. But flawed economic and political systems make it impossible for businesses to mitigate about 80 percent of negative impacts. These impacts often return to harm companies, for example, in the form of market rejection, lawsuits and reputation damage. System change is the most important sustainability issue. Protecting business and society requires substantially shifting the focus of corporate sustainability strategies from company change to system change. A growing number of collaborative system change efforts are being implemented. Most focus on specific issues, sectors or system flaws. They frequently are ineffective because they do not use a whole system approach. All major aspects of human society are connected. Root causes, key leverage points and most effective solutions often lie outside of issue-specific areas. Climate change, economic reform and other complex issues can only be effectively addressed through a whole system approach. This paper summarizes important economic and political system flaws and describes a collaborative, whole system approach for engaging the corporate and financial sectors in system change.

  1. Activities of Institute of Radiation Protection and Dosimety/Brazil as Technical and Scientific Support Organization on Occupational Radiation Protection

    International Nuclear Information System (INIS)

    Da Silva, F.C.A.; Ferreira, P.R.; Matta, L.E.C.; Peres, M.A.L.; Godoy, J.M.; Alencar, M.A.V.; Carlos, M.T.; Souza-Santos, D.; Leocadio, J.C.; Oliveira, M.S.

    2010-01-01

    There are, in Brazil, about 126,000 workers registered on National Dose Registry System (SRD/IRD) as occupationally exposed. They work on 4,000 radioactive installations, 20 nuclear fuel cycle installations and with 90,000 x-ray diagnostic devices. There are two main Regulatory Authorities to license and control these installations on nuclear and radioactive areas, and another Regulatory Authority that is responsible for safety and health protection of workers on their labour activities. Belonging to structure of the National Commission of Nuclear Energy (CNEN-Brazil) there is an Institute dedicated to radiation protection, dosimetry and metrology of ionizing radiation, that is the Institute of Radiation Protection and Dosimetry (IRD). This paper presents two main IRD activities related to occupational radiation protection that can be seen as example of technical and scientific support to Regulatory Authorities: the Radiation Overexposure Analysis that is performed by the Radiation Overexposure Analysis Group (GADE) and the Approval of Individual Monitoring Services and Calibration Laboratory of Equipment used in Radiation Protection that is performed by the Committee for the Evaluation of Essay and Calibration Services (CASEC). (author)

  2. Overvoltage protection system for wireless power transfer systems

    Science.gov (United States)

    Chambon, Paul H.; Jones, Perry T.; Miller, John M.; Onar, Omer C.; Tang, Lixin; White, Clifford P.

    2017-05-02

    A wireless power transfer overvoltage protection system is provided. The system includes a resonant receiving circuit. The resonant receiving circuit includes an inductor, a resonant capacitor and a first switching device. The first switching device is connected the ends of the inductor. The first switching device has a first state in which the ends of the inductor are electrically coupled to each other through the first switching device, and a second state in which the inductor and resonant capacitor are capable of resonating. The system further includes a control module configured to control the first switching device to switching between the first state and the second state when the resonant receiving circuit is charging a load and a preset condition is satisfied and otherwise, the first switching device is maintained in the first state.

  3. Distributed systems for the protection of nuclear stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-01-01

    The advantages of distributed control systems usually mentioned are improved exploitation, cost reduction, and adaptation to changes in technology. These advantages are obviously very interesting for nuclear power plant applications, and many such systems have been proposed. This note comments on the application of the distributed system concept to protection systems - what should be distributed - and closes with a brief description of a protection system based on microprocessors for pressurized water stations being built in France. (auth) [fr

  4. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1976-01-01

    Reactor protection systems for nuclear power plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. The paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  5. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1977-01-01

    Reactor Protection Systems for Nuclear Power Plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. This paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  6. Seismic design criteria of fire protection systems for DOE facilities

    International Nuclear Information System (INIS)

    Hardy, G.; Cushing, R.; Driesen, G.

    1991-01-01

    Fire protection systems are critical to the safety of personnel and to the protection of inventory during any kind of emergency situation that involves a fire. The importance of these fire protection systems is hightened for DOE facilities which often house nuclear, chemical or scientific processes. Current research into the topic of open-quotes fires following earthquakesclose quotes has demonstrated that the risks of a fire starting as a result of a major earthquake can be significant. Thus, fire protection systems need to be designed to withstand the anticipated seismic event for the site in question

  7. Novel Directional Protection Scheme for the FREEDM Smart Grid System

    Science.gov (United States)

    Sharma, Nitish

    This research primarily deals with the design and validation of the protection system for a large scale meshed distribution system. The large scale system simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms, to provide a virtual testing platform for the Future Renewable Electric Energy Delivery and Management (FREEDM) system. It is also used to validate the cases of power system protection, renewable energy integration and storage, and load profiles. The protection of the FREEDM system against any abnormal condition is one of the important tasks. The addition of distributed generation and power electronic based solid state transformer adds to the complexity of the protection. The FREEDM loop system has a fault current limiter and in addition, the Solid State Transformer (SST) limits the fault current at 2.0 per unit. Former students at ASU have developed the protection scheme using fiber-optic cable. However, during the NSF-FREEDM site visit, the National Science Foundation (NSF) team regarded the system incompatible for the long distances. Hence, a new protection scheme with a wireless scheme is presented in this thesis. The use of wireless communication is extended to protect the large scale meshed distributed generation from any fault. The trip signal generated by the pilot protection system is used to trigger the FID (fault isolation device) which is an electronic circuit breaker operation (switched off/opening the FIDs). The trip signal must be received and accepted by the SST, and it must block the SST operation immediately. A comprehensive protection system for the large scale meshed distribution system has been developed in PSCAD with the ability to quickly detect the faults. The validation of the protection system is performed by building a hardware model using commercial relays at the ASU power laboratory.

  8. The Protective Arm of the Renin Angiotensin System (RAS)

    DEFF Research Database (Denmark)

    understanding of the protective side of the Renin Angiotensin System (RAS) involving angiotensin AT2 receptor, ACE2, and Ang(1-7)/Mas receptor Combines the knowledge of editors who pioneered research on the protective renin angiotensin system including; Dr. Thomas Unger, one of the founders of AT2 receptor......The Protective Arm of the Renin Angiotensin System: Functional Aspects and Therapeutic Implications is the first comprehensive publication to signal the protective role of a distinct part of the renin-angiotensin system (RAS), providing readers with early insight into a complex system which...... will become of major medical importance in the near future. Focusing on recent research, The Protective Arm of the Renin Angiotensin System presents a host of new experimental studies on specific components of the RAS, namely angiotensin AT2 receptors (AT2R), the angiotensin (1-7) peptide with its receptor...

  9. DNA damage protection and 5-lipoxygenase inhibiting activity of ...

    African Journals Online (AJOL)

    DNA damage caused by free radical is associated with mutation-based health impairment. The protective effect on DNA damage mediated by hydroxyl radical and peroxynitrite radical, and the inhibiting activity on 5-lipoxygenase of areca inflorescence extracts were studied in vitro. The results show that the boiling water ...

  10. Tea and coronary heart disease : protection through estrogenlike activity?

    NARCIS (Netherlands)

    Geleijnse, J.M.; Witteman, J.C.; Launer, L.J.; Lamberts, S.J.; Pols, H.A.

    2000-01-01

    Tea drinking appears to be protective against coronary heart disease in a number of epidemiologic studies. It has been suggested that tea flavonols with antioxidative activity, including quercetin, kaempferol, and myricetin,1 could account for the favorable effect on cardiovascular health. In the

  11. Mechanisms of protection of information in computer networks and systems

    Directory of Open Access Journals (Sweden)

    Sergey Petrovich Evseev

    2011-10-01

    Full Text Available Protocols of information protection in computer networks and systems are investigated. The basic types of threats of infringement of the protection arising from the use of computer networks are classified. The basic mechanisms, services and variants of realization of cryptosystems for maintaining authentication, integrity and confidentiality of transmitted information are examined. Their advantages and drawbacks are described. Perspective directions of development of cryptographic transformations for the maintenance of information protection in computer networks and systems are defined and analyzed.

  12. Report on task I: fire protection system study

    International Nuclear Information System (INIS)

    Bernard, E.A.; Cano, G.L.

    1977-02-01

    This study (1) evaluates, on a comparative basis, the national and international regulatory and insurance standards that serve as guidance for fire protection within the nuclear power industry; (2) analyzes the recommendations contained in the major reports on the Browns Ferry Fire; (3) proposes quantitative safety goals and evaluation methods for Nuclear Power Plant Fire Protection Systems (NPPFPS); (4) identifies potential improvements that may be incorporated into NPPFPS; and (5) recommends a plan of action for continuation of the fire protections systems study

  13. ADASY (Active Daylighting System)

    Science.gov (United States)

    Vázquez-Moliní, Daniel; González-Montes, Mario; Fernández-Balbuena, Antonio Á.; Bernabéu, Eusebio; García-Botella, Ángel; García-Rodríguez, Lucas; Pohl, Wilfried

    2009-08-01

    The main objective of ADASY (Active Daylighting System) work is to design a façade static daylighting system oriented to office applications, mainly. The goal of the project is to save energy by guiding daylight into a building for lighting purpose. With this approach we can reduce the electrical load for artificial lighting, completing it with sustainable energy. The collector of the system is integrated on a vertical façade and its distribution guide is always horizontal inside of the false ceiling. ADASY is designed with a specific patent pending caption system, a modular light-guide and light extractor luminaire system. Special care has been put on the final cost of the system and its building integration purpose. The current ADASY configuration is able to illuminate 40 m2 area with a 300lx-400lx level in the mid time work hours; furthermore it has a good enough spatial uniformity distribution and a controlled glare. The data presented in this study are the result of simulation models and have been confirmed by a physical scaled prototype. ADASY's main advantages over regular illumination systems are: -Low maintenance; it has not mobile pieces and therefore it lasts for a long time and require little attention once installed. - No energy consumption; solar light continue working even if there has been a power outage. - High quality of light: the colour rendering of light is very high - Psychological benefits: People working with daylight get less stress and more comfort, increasing productivity. - Health benefits

  14. 78 FR 44475 - Protection System Maintenance Reliability Standard

    Science.gov (United States)

    2013-07-24

    ... that the performance or product has some reliability-related value, then the requirement will have...] Protection System Maintenance Reliability Standard AGENCY: Federal Energy Regulatory Commission, Energy... Commission proposes to approve a revised Reliability Standard, PRC-005- 2--Protection System Maintenance, to...

  15. Impact of Y2K problem on physical protection system

    International Nuclear Information System (INIS)

    Kumar, R.; Swadia, N.S.; Zanwar, P.S.; Mishra, G.P.; Salunke, A.S.; Nigam, R.K.

    1999-01-01

    Year 2000 related system failures/problems in Physical Protection System pose no threat to general safety and functioning of any nuclear facility. But there can be potential security threats having radiation safety and non-proliferation concern and hence should be given due importance. Reviewing and testing Physical Protection System for Y2K compliance are easier than other systems as it does not directly affect operation of the plant. The existing emergency response capability at the nuclear facilities should be utilizes effectively to mitigate any Y2K induced events on Physical Protection System with dedicated manpower and channeled efforts

  16. Evolution of Radiation Protection System in Kenya

    International Nuclear Information System (INIS)

    Maina, J. A. W.

    2004-01-01

    Promulgation of radiation protection legislation in Kenya dates back to 1982, was revised in 1985 and became operational in 1986. This law, the Radiation Protection Act, establishes the Radiation Protection Board as the National Regulatory Authority, with an executive Inspectorate headed by the Secretary to the Board. Subsidiary legislation on radiological practices and standards were subsequently published. The Inspectorate carries out the National programme for notification, authorization, inspection and enforcement. Nuclear applications for peaceful purposes in Kenya are on the increase in all major fields of socio-economic development. Provision of regulatory services, guidance and enforcement procedures, has had a net growth over the last fifteen years. However, staff retention has been declining over the years in a market where job opportunities, with relatively high incentives, are high either inside or outside the country. Human and equipment resource development has therefore not kept pace and this has hampered effective and efficient provision of services. The poor status of the economy has had its impact on delivery of quality, effective and efficient radiation protection services. Provision of radiation services and acquisition of radiation detection and measurement equipment in the country has been generally lacking dating as far back as 1995. During the period 1989 to present, Kenya's Regulatory Authority, the Radiation Protection Board, undertook to provide personal monitoring, quality assurance, radioanalysis, and equipment calibration. Over the years these services have stalled due to outdated equipment most of which have broken down. A maintenance and calibration service for nuclear equipment is an expensive cross-boarder issue. Budgetary constraints, insufficient human and equipment resources, and a perennial 'brain drain' has placed limitations to the effectiveness and efficiency of implementation of the National programmes and slowed the

  17. Electronic Systems for the Protection of Superconducting Elements in the LHC

    CERN Document Server

    Denz, R

    2006-01-01

    The Large Hadron Collider LHC, currently under construction at CERN, will incorporate an unprecedented number of superconducting magnets, busbars and current leads. As most of these elements depend on active protection in case of a transition from the superconducting to the resistive state, the so-called quench, a protection system based on modern, state of the art electronics has been developed.

  18. Flight envelope protection system for unmanned aerial vehicles

    KAUST Repository

    Claudel, Christian G.; Shaqura, Mohammad

    2016-01-01

    Systems and methods to protect the flight envelope in both manual flight and flight by a commercial autopilot are provided. A system can comprise: an inertial measurement unit (IMU); a computing device in data communication with the IMU

  19. System and method for quench protection of a superconductor

    Science.gov (United States)

    Huang, Xianrui; Sivasubramaniam, Kiruba Haran; Bray, James William; Ryan, David Thomas

    2008-03-11

    A system and method for protecting a superconductor from a quench condition. A quench protection system is provided to protect the superconductor from damage due to a quench condition. The quench protection system comprises a voltage detector operable to detect voltage across the superconductor. The system also comprises a frequency filter coupled to the voltage detector. The frequency filter is operable to couple voltage signals to a control circuit that are representative of a rise in superconductor voltage caused by a quench condition and to block voltage signals that are not. The system is operable to detect whether a quench condition exists in the superconductor based on the voltage signal received via the frequency filter and to initiate a protective action in response.

  20. The objectives and activities of the Canadian Radiation Protection Association

    International Nuclear Information System (INIS)

    Haynes, M.J.

    1998-01-01

    The Canadian Nuclear Society and the Canadian Radiation Protection Association are working to develop an agreement between the organizations to facilitate working together on issues of common interest. This paper will present the objectives, the organizational structure and major areas of activity of the Canadian Radiation Protection Association. It is a reciprocal presentation of one given earlier this year by Mr. Fred Boyd of the CNS to the CRPA annual conference. The intent is to help the membership of each organization better understand the objectives and interests of the other. (author)

  1. Measuring the impact of child protection through Activation States

    OpenAIRE

    Pawlaczek, Z; Bringer, JD; Cockburn, C; Nutt, G; Pitchford, A; Russell, K; Brackenridge, CH

    2005-01-01

    Child protection (CP) has risen to the top of the UK sports policy agenda in the past four years and the Football Association has invested in this major strategy as part of its commitment to “use the power of football to build a better future” (FA, 2000a). Evidencing the impact of child protection is, however, a complex task, exacerbated by the dearth of measurement tools that exist for this purpose in sport. This article presents a new model of ‘Activation States’ that has been designed and...

  2. Design and evaluation of physical protection systems of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    An, Jin Soo; Lee, Hyun Chul; Hwang, In Koo; Kwack, Eun Ho; Choi, Yung Myung

    2001-06-01

    Nuclear material and safety equipment of nuclear facilities are required to be protected against any kind of theft or sabotage. Physical protection is one of the measures to prevent such illegally potential threats for public security. It should cover all the cases of use, storage, and transportation of nuclear material. A physical protection system of a facility consists of exterior intrusion sensors, interior intrusion sensors, an alarm assessment and communication system, entry control systems, access delay equipment, etc. The design of an effective physical protection system requires a comprehensive approach in which the designers define the objective of the system, establish an initial design, and evaluate the proposed design. The evaluation results are used to determine whether or not the initial design should be modified and improved. Some modelling techniques are commonly used to analyse and evaluate the performance of a physical protection system. Korea Atomic Energy Research Institute(KAERI) has developed a prototype of software as a part of a full computer model for effectiveness evaluation for physical protection systems. The input data elements for the prototype, contain the type of adversary, tactics, protection equipment, and the attributes of each protection component. This report contains the functional and structural requirements defined in the development of the evaluation computer model.

  3. Active Protection of an MgB2 Test Coil

    Science.gov (United States)

    Park, Dong Keun; Hahn, Seungyong; Bascuñán, Juan; Iwasa, Yukikazu

    2011-01-01

    This paper presents results of a study, experimental and computational, of a detect-and-activate-the-heater protection technique applied to a magnesium diboride (MgB2) test coil operated in semi-persistent mode. The test coil with a winding ID of 25 cm and wound with ~500-m long reacted MgB2 wire was operated at 4.2 K immersed in a bath of liquid helium. In this active technique, upon the initiation of a “hot spot” of a length ~10 cm, induced by a “quench heater,” a “protection heater” (PH) of ~600-cm long planted within the test coil is activated. The normal zone created by the PH is large enough to absorb the test coil’s entire initial stored energy and still keeps the peak temperature within the winding below ~260 K. PMID:22081754

  4. Operational test report - Project W-320 cathodic protection systems

    International Nuclear Information System (INIS)

    Bowman, T.J.

    1998-01-01

    Washington Administrative Code (WAC) 173-303-640 specifies that corrosion protection must be designed into tank systems that treat or store dangerous wastes. Project W-320, Waste Retrieval Sluicing System (WRSS), utilizes underground encased waste transfer piping between tanks 241-C-106 and 241-AY-102. Corrosion protection is afforded to the encasements of the WRSS waste transfer piping through the application of earthen ionic currents onto the surface of the piping encasements. Cathodic protection is used in conjunction with the protective coatings that are applied upon the WRSS encasement piping. WRSS installed two new two rectifier systems (46 and 47) and modified one rectifier system (31). WAC 173-303-640 specifies that the proper operation of cathodic protection systems must be confirmed within six months after initial installation. The WRSS cathodic protection systems were energized to begin continuous operation on 5/5/98. Sixteen days after the initial steady-state start-up of the WRSS rectifier systems, the operational testing was accomplished with procedure OTP-320-006 Rev/Mod A-0. This operational test report documents the OTP-320-006 results and documents the results of configuration testing of integrated piping and rectifier systems associated with the W-320 cathodic protection systems

  5. Collaborative Point Paper on Active Protection Systems

    National Research Council Canada - National Science Library

    2006-01-01

    The North American Technology and Industrial Base Organization (NATIBO) fosters cooperative planning for technology and industrial base program development among and between the Defense Departments of the U.S. and Canada...

  6. Discussion on several problems in evolution of radiation protection system

    International Nuclear Information System (INIS)

    Ziqiang, P.

    2004-01-01

    As viewed from the standpoint of radiation protection practice, it is necessary that the current system of radiological protection should be made more simple and coherent. The human-based protective measures alone are far from having met the requirements of environmental protection in many circumstances. Protecting the environment from ionising radiation would be implicated in radiation protection. Collective dose is an useful indicator, of which applicable extent should be defined. Using such an quantity could help improve radiation protection level, but applicable conditions should be indicated, temporal or spatial. Natural radiation is the largest contributor to the radiation exposure of human. Occupational exposure from natural radiation should be controlled, for occupations such as underground miners and air crew. Controlling both man-made and natural radiation exposure of pregnant women and children needs to be enhanced, especially radiological diagnosis and treatment. China radiation protection community, as a whole, is paying considerable attention to the ICRP's new Recommendations. Prof. Clarke's article 'A Report on Progress towards New Recommendations', a communication from the International Commission on Radiological Protection, has been translated into Chinese and published on Radiation Protection, the Official Journal of China Radiation Protection Society with a view of intensifying awareness of the new Recommendations within more radiation protection workers and people concerned. In addition, a special meeting was convened in early 2002 to address the comments on the new Recommendations. (author)

  7. 44 CFR 65.14 - Remapping of areas for which local flood protection systems no longer provide base flood protection.

    Science.gov (United States)

    2010-10-01

    ... local flood protection systems no longer provide base flood protection. 65.14 Section 65.14 Emergency... § 65.14 Remapping of areas for which local flood protection systems no longer provide base flood... process of restoring a flood protection system that was: (i) Constructed using Federal funds; (ii...

  8. Implementation Of Conservation Policy Through The Protection Of Life Support System In The Karimunjawa National Park

    Science.gov (United States)

    Ariyani, Nur Anisa Eka; Kismartini

    2018-02-01

    The Karimunjawa National Park as the only one marine protected area in Central Java, managed by zonation system has decreased natural resources in the form of decreasing mangrove forest area, coral cover, sea biota population such as clams and sea cucumbers. Conservation has been done by Karimunjawa National Park Authority through protection of life support system activities in order to protect the area from degradation. The objective of the research is to know the implementation of protection and security activities of Karimunjawa National Park Authority for the period of 2012 - 2016. The research was conducted by qualitative method, processing secondary data from Karimunjawa National Park Authority and interview with key informants. The results showed that protection and security activities in The Karimunjawa National Park were held with three activities: pre-emptive activities, preventive activities and repressive activities. Implementation of conservation policy through protection of life support system is influenced by factors of policy characteristic, resource factor and environmental policy factor. Implementation of conservation policy need support from various parties, not only Karimunjawa National Park Authority as the manager of the area, but also need participation of Jepara Regency, Central Java Provinces, communities, NGOs, researchers, developers and tourism actors to maintain and preserve existing biodiversity. Improving the quality of implementors through education and training activities, the availability of the state budget annually and the support of stakeholders is essential for conservation.

  9. A New Physical Protection System Design and Evaluation Process

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Heoksoon; Kim, Myungsu; Bae, Yeongkyoung; Na, Janghwan [KHNP-CRI, Daejeon (Korea, Republic of)

    2014-10-15

    International Atomic Energy Agency(IAEA) had established security-related department and has been strengthening security measures against possible sabotage. IAEA enforces the recommendations for the physical protection of NPPs in the INFCIRC/ 225/Rev.5 to the member states and U.S. NRC also enforces the similar requirements in 10 CFR 73.55. Thus, in order to let Korean NPPs meet the new requirements in INFCIRC/225/Rev.5 or U.S. NRC requirements, Korea nuclear licensee should develop or establish appropriate physical protection system (PPS) design methods for the physical protection of the operating NPPs and new NPPs. KHNP is doing the project of 'Development of APR1400 Physical Protection System Design (2012- 2015, KHNP/KAERI /KEPCO E-C)'. This paper describes overview of a physical protection system (PPS) design and evaluation for an advanced nuclear power plant. It found that a new physical protection system (PPS)design and evaluation. KHNP is doing the project of Physical Protection System design according to U.S. NRC requirements and IAEA requirements in INFCIRC /225 /Rev.5 and will complete by 7.31, 2015 for development of APR1400 Physical Protection System. After completing this project, the results of project are expected to apply new NPPs.

  10. Quantitative evaluation of physical protection system in nuclear power plant

    International Nuclear Information System (INIS)

    Sun Yahua; Li Bin; Li Shiju

    2009-01-01

    Based on the prompt detection analysis, this paper introduced one analysis model of intrusion path in nuclear power plant by means of morphology analysis and developed the evaluation software for path model analysis of physical protection system. Quantitative analysis on three elements (detection, delay, and response) of physical protection system was presented with an imaginary intrusion event example in Mac Arthur nuclear center. The results indicated that the path prompt detection analysis worked effectively to find the weak point of the physical protection system in NPP, and meantime we can also get the high cost-effectiveness improved measures. It is an effective approach to evaluate the overall performance of the system. (authors)

  11. EMP protection procedure for electrical/electronic systems

    International Nuclear Information System (INIS)

    Latorre, V.R.

    1976-01-01

    This paper presents a procedure for the protection engineer to follow in assessing a system with respect to its susceptibility to an electromagnetic pulse (EMP), and in determining whether the system requires protection. If the system is determined to be vulnerable to EMP, the procedure also indicates how to decide upon the most suitable protection scheme. The discussion centers on two flow charts, which illustrate the step-by-step procedure which utilizes the necessary ingredients of EMP protection engineering discussed in a previous paper. The description of the protection procedure is divided into two parts: the first dealing with issues on the macroscopic or large-scale system level, while the second is concerned with operations on the subsystem level or lower

  12. Architecture and Fault Identification of Wide-area Protection System

    Directory of Open Access Journals (Sweden)

    Yuxue Wang

    2012-09-01

    Full Text Available Wide-area protection system (WAPS is widely studied for the purpose of improvng the performance of conventional backup protection. In this paper, the system architecture of WAPS is proposed and its key technologies are discussed in view of engineering projects. So a mixed structurecentralized-distributed structure which is more suitable for WAPS in limited power grid region, is obtained based on the advantages of the centralized structure and distributed structure. Furthermore, regional distance protection algorithm was taken as an example to illustrate the functions of the constituent units. Faulted components can be detected based on multi-source imformation fuse in the algorithm. And the algorithm cannot only improve the selectivity, the rapidity, and the reliability of relaying protection but also has high fault tolerant capability. A simulation of 220 kV grid systems in Easter Hubei province shows the effectiveness of the wide-area protection system presented by this paper.

  13. New measuring and protection system at VR-1 training reactor

    International Nuclear Information System (INIS)

    Kropik, M.; Jurickova, M.

    2006-01-01

    The contribution describes the new measuring and protection system of the VR-1 training reactor. The measuring and protection system upgrade is an integral part of the reactor I and C upgrade. The new measuring and protection system of the VR-1 reactor consists of the operational power measuring and the independent power protection systems. Both systems measure the reactor power and power rate, initiate safety action if safety limits are exceeded and send data (power, power rate, status, etc.) to the reactor control system. The operational power measuring system is a full power range system that receives signal from a fission chamber. The signal is evaluated according to the reactor power either in the pulse or current mode. The current mode utilizes the DC current and Campbell techniques. The new independent power protection system operates in the two highest reactor power decades. It receives signals from a boron chamber and evaluates it in the pulse mode. Both systems are computer based. The operational power measuring and independent power protection systems are diverse - different types and location of chambers, completely different hardware, software algorithms for the power and power rate calculations, software development tools and teems for the software manufacturing. (author)

  14. Protection of Distribution Systems with Distributed Energy Resources

    DEFF Research Database (Denmark)

    Bak-Jensen, Birgitte; Browne, Matthew; Calone, Roberto

    of 17 months of work of the Joint Working Group B5/C6.26/CIRED “Protection of Distribution Systems with Distributed Energy Resources”. The working group used the CIGRE report TB421 “The impact of Renewable Energy Sources and Distributed Generation on Substation Protection and Automation”, published...... by WG B5.34 as the entry document for the work on this report. In doing so, the group aligned the content and the scope of this report, the network structures considered, possible islanding, standardized communication and adaptive protection, interface protection, connection schemes and protection...... are listed (chapter 3). The first main part of the report starts with a summary of the backgrounds on DER and current practices in protection at the distribution level (chapter 4). This chapter contains an analysis of CIGRE TB421, protection relevant characteristics of DER, a review of current practices...

  15. Discussion on some problems in evolution of radiation protection system

    International Nuclear Information System (INIS)

    Pan Ziqiang

    2003-01-01

    In radiation protection practice in China, the appropriate simplification and better coordination for the existing radiation protection system are necessary. The human-based protective measures alone could not meet the requirements of the environmental protection in many circumstances. Protecting the environment from ionizing radiation would be implicated in radiation protection. Collective dose is an useful index, its applicable scope should be well defined. Using such an quantity can help increase radiation protection level, but applicable conditions should be defined, such as time and space. Natural radiation is the largest contributor of the radiation exposure to human. Occupational exposure from natural radiation should be controlled, such as to underground miners and air crew. Controlling both man-made and natural radiation exposure to pregnant women and children needs to be enhanced, especially radiological diagnosis and therapy

  16. A Cause-Consequence Chart of a Redundant Protection System

    DEFF Research Database (Denmark)

    Nielsen, Dan Sandvik; Platz, O.; Runge, B.

    1975-01-01

    A cause-consequence chart is applied in analysing failures of a redundant protection system (a core spray system in a nuclear power plant). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of the protection system. The test policy of compone...... of components is taken into account. The possibility of using parameter variation as a basis for the choice of test policy is indicated.......A cause-consequence chart is applied in analysing failures of a redundant protection system (a core spray system in a nuclear power plant). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of the protection system. The test policy...

  17. Practical Approach on Lightning and Grounding Protection System

    OpenAIRE

    Shan Jose Varghese

    2015-01-01

    Lightning Protection and Grounding of Electrical and Mechanical equipment’s for the Protection of the Human Beings, Structure of the building and equipment protection, safe working of the Worker at Industry as per my latest practical knowledge in the site environment in extreme climatic condition of low lying areas of the Gulf Region in the challenging projects. All the conductor calculation, Lightning Risk Factor calculations, all the system information regarding the ...

  18. Annexes to the lecture on reactor protection system including engineered features actuation system

    International Nuclear Information System (INIS)

    Palmaers, W.

    1982-01-01

    The present paper deals with the fundamentals for a reactor protection system and discusses the following topics: - System lay-out - Analog measured data acquisition - Analog measured data processing - Limit value generation and logical gating - Procesing of the reactor protection actuation signals - Decoupling of the reactor protection system - Mechanical lay-out - Monitoring system and - Emergency control station. (orig./RW)

  19. Radiation protection of vitamins in aqueous systems

    International Nuclear Information System (INIS)

    Kishore, K.; Moorthy, P.N.; Rao, K.N.

    1976-01-01

    A study of the radiation induced decomposition of the B-group vitamins has been carried out in aqueous media at room temperature as well as in rigid matrices at low temperature. The detailed results on the effect of glucose and oxygen as protective additives at the different temperatures are presented in the case of Thiamine (Vitamin B 1 ). Comparative data are given on the extent of decomposition of this and other vitamins of the B-group at room temperature and at 193 K. The importance of these results in connection with the radiation sterilization of pharmaceutical preparations is indicated. (author)

  20. Radiation protection of vitamins in aqueous systems

    International Nuclear Information System (INIS)

    Kishore, K.; Moorthy, P.N.; Rao, K.N.

    1976-01-01

    Thiamine and other vitamins of the B complex group are highly sensitive to γ radiation in aqueous solution owing to their high reactivity with the primary species formed by radiolysis of water, viz. hydrated electrons and hydroxyl radicals. In order to protect these compounds from radiolytic degradation, nitrous oxide and oxygen have been used as scavengers for the hydrated electrons and glucose for the hydroxyl radicals. By comparison of uv spectra it is shown that the above vitamins do not undergo radiolytic degradation in presence of nitrous oxide and glucose or oxygen and glucose. The importance of these results in connection with the sterilization of vitamin preparations is discussed. (author)

  1. Distributed Power-Generation Systems and Protection

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng; Yang, Dongsheng

    2017-01-01

    the challenging issues and, more importantly, to leverage the energy generation, stringent demands from both utility operators and consumers have been imposed on the DPGS. Furthermore, as the core of energy conversion, numerous power electronic converters employing advanced control techniques have been developed...... for the DPGS to consolidate the integration. In light of the above, this paper reviews the power-conversion and control technologies used for DPGSs. The impacts of the DPGS on the distributed grid are also examined, and more importantly, strategies for enhancing the connection and protection of the DPGS...

  2. Design principles for radiological protection instrumentation systems

    International Nuclear Information System (INIS)

    Wells, F.H.; Powell, R.G.

    1981-02-01

    This Code of Practice takes the form of recommendations intended for designers and installers of Radiological Protection Instrumentation, and should also be of value to the newcomer to the R.P.I. field. Topics are discussed under the following headings: outline of R.P.I. requirements, specifying the requirement, satisfying the requirements, (overall design, availability and reliability, information display, human factors, power supplies, manufacture, quality assurance, testing, and cost analysis), supply, location and operation of the equipment, importance of documentation. (U.K.)

  3. NSTX-U Digital Coil Protection System Software Detailed Design

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-06-01

    The National Spherical Torus Experiment (NSTX) currently uses a collection of analog signal processing solutions for coil protection. Part of the NSTX Upgrade (NSTX-U) entails replacing these analog systems with a software solution running on a conventional computing platform. The new Digital Coil Protection System (DCPS) will replace the old systems entirely, while also providing an extensible framework that allows adding new functionality as desired.

  4. 78 FR 30870 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2013-05-23

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: National Marine Protected...) invited federal, state, commonwealth, and territorial marine protected area (MPA) programs with... of Marine Protected Areas of the United States (Framework), developed in response to Executive Order...

  5. Criminal law repercussions on the Civil Protection System

    Science.gov (United States)

    Altamura, M.; Musso, L.

    2009-09-01

    The legal systems of our Countries provide the citizenship with a high level of protection. Personal safety and the protection of property are guaranteed by the State through organized structures among which we can include the Civil Protection. The progress of science and technology has greatly improved monitoring tools, currently used by the Civil Protection, which allow, to a certain extent, to predict and prevent risk and natural hazards. The assertion of an individual right, which in some cases has reached a constitutional rank, to benefit from Civil Protection services and the widespread perception throughout the citizenship of the competence of the system to prevent disasters, often causes people to take legal action against Civil Protection authorities should they fail in their duties to protect. However, the attempt of having both recognized an economic compensation for the suffered loss and the punishment of those whom misled, frequently undergoes criminal law. This process could have results that may jeopardize the effectiveness of Civil Protection service without meeting citizens’ demands. A dual effort is thus necessary in order to solve such a problem. On the one hand, an interdisciplinary knowledge needs to pervade criminal law in an attempt to relieve its self-referentiality and pretended supremacy. On the other hand an alternative, and more agile, system -such as civil or administrative law- has to be identified in order to respond to the legitimate requests for protection in the case of a faulty behaviour of the authorities.

  6. Active Anti-erosion Protection Strategy in Tamarisk (Tamarix aphylla)

    Science.gov (United States)

    Han, Zhiwu; Yin, Wei; Zhang, Junqiu; Niu, Shichao; Ren, Luquan

    2013-12-01

    Plants have numerous active protection strategies for adapting to complex and severe environments. These strategies provide endless inspiration for extending the service life of materials and machines. Tamarisk (Tamarix aphylla), a tree that thrives in raging sandstorm regions, has adapted to blustery conditions by evolving extremely effective and robust erosion resistant characteristics. However, the relationships among its surface cracks, internal histology and biomechanics, such as cracks, rings, cells, elasticity modulus and growth stress, which account for its erosion resistance, remain unclear. This present study reveals that the directionally eccentric growth rings of tamarisk, which are attributed to reduced stress and accelerated cell division, promote the formation of surface cracks. The windward rings are more extensive than the leeward side rings. The windward surfaces are more prone to cracks, which improves erosion resistance. Our data provide insight into the active protection strategy of the tamarisk against wind-sand erosion.

  7. Discussion on radiation protection system from ethical issues

    International Nuclear Information System (INIS)

    Li, Xutong; Guo, Qiuju

    2002-01-01

    This paper discussed the relationship between radiation protection system and ethical principle, viz. equity and efficiency. According to the authors' opinions, the main problem that the system of radiation protection facing now is the dose-limitation principle cannot incarnate the equity principle completely. Even though the distinguishing between practice and intervention is no other than solving the problem, but the scheme is not perfect still. Ethical issues should be given more attention and be more researched when we try to modify the radiation protection system today

  8. Foundations for Protecting Renewable-Rich Distribution Systems.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brahma, Sukumar [New Mexico State Univ., Las Cruces, NM (United States); Ranade, Satish [New Mexico State Univ., Las Cruces, NM (United States)

    2016-11-01

    High proliferation of Inverter Interfaced Distributed Energy Resources (IIDERs) into the electric distribution grid introduces new challenges to protection of such systems. This is because the existing protection systems are designed with two assumptions: 1) system is single-sourced, resulting in unidirectional fault current, and (2) fault currents are easily detectable due to much higher magnitudes compared to load currents. Due to the fact that most renewables interface with the grid though inverters, and inverters restrict their current output to levels close to the full load currents, both these assumptions are no longer valid - the system becomes multi-sourced, and overcurrent-based protection does not work. The primary scope of this study is to analyze the response of a grid-tied inverter to different faults in the grid, leading to new guidelines on protecting renewable-rich distribution systems.

  9. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  10. Advanced Emergency Braking Controller Design for Pedestrian Protection Oriented Automotive Collision Avoidance System

    OpenAIRE

    Lie, Guo; Zejian, Ren; Pingshu, Ge; Jing, Chang

    2014-01-01

    Automotive collision avoidance system, which aims to enhance the active safety of the vehicle, has become a hot research topic in recent years. However, most of the current systems ignore the active protection of pedestrian and other vulnerable groups in the transportation system. An advanced emergency braking control system is studied by taking into account the pedestrians and the vehicles. Three typical braking scenarios are defined and the safety situations are assessed by comparing the cu...

  11. Selectivity of power system protections at power swings in power system

    Directory of Open Access Journals (Sweden)

    Jan Machowski

    2012-12-01

    Full Text Available The paper discusses out-of-step protection systems such as: generator pole slip protections, out of step tripping protections, distance protections of step-up transformer, distance protections of transmission lines and transformers, power swing blocking, and special out-of-step protection. It is shown that all these protections make up a protection system, to which a setting concept uniform for the entire power system has to be applied. If a power system is inappropriately equipped with these protections, or their settings are inappropriate, they may operate unselectively, thus contributing to the development of power system blackouts. In the paper the concepts for a real power system are given for the two stages: target stage fully compliant with selectivity criteria, and transitional stage between the current and target stages.

  12. Adaptive Overcurrent Protection for Microgrids in Extensive Distribution Systems

    DEFF Research Database (Denmark)

    Lin, Hengwei; Guerrero, Josep M.; Jia, Chenxi

    2016-01-01

    Microgrid is regarded as a new form to integrate the increasing penetration of distributed generation units (DGs) in the extensive distribution systems. This paper proposes an adaptive overcurrent protection strategy for a microgrid network. The protection coordination of the overcurrent relays...... measurements in another neural network model. Reconfigurations can be performed to modify the settings of the on-field relays to enhance the reliable operation for the different operational situations. The test results show that the adaptive overcurrent protection scheme with the assistance of estimation model...... can modify the protective settings for the new operation state accurately and intelligently....

  13. 75 FR 972 - Nomination of Existing Marine Protected Areas to the National System of Marine Protected Areas

    Science.gov (United States)

    2010-01-07

    ... Marine Protected Areas to the National System of Marine Protected Areas AGENCY: NOAA, Department of... Federal, State and territorial marine protected area programs to join the National System of Marine Protected Areas. SUMMARY: NOAA and the Department of the Interior (DOI) invited Federal, State, commonwealth...

  14. Activation of Nrf2 protects against triptolide-induced hepatotoxicity.

    Directory of Open Access Journals (Sweden)

    Jia Li

    Full Text Available Triptolide, the major active component of Tripterygium wilfordii Hook f. (TWHF, has a wide range of pharmacological activities. However, the toxicities of triptolide, particularly the hepatotoxicity, limit its clinical application. The hepatotoxicity of triptolide has not been well characterized yet. The aim of this study was to investigate the role of NF-E2-related factor 2 (Nrf2 in triptolide-induced toxicity and whether activation of Nrf2 could protect against triptolide-induced hepatotoxicity. The results showed that triptolide caused oxidative stress and cell damage in HepG2 cells, and these toxic effects could be aggravated by Nrf2 knockdown or be counteracted by overexpression of Nrf2. Treatment with a typical Nrf2 agonist, sulforaphane (SFN, attenuated triptolide-induced liver dysfunction, structural damage, glutathione depletion and decrease in antioxidant enzymes in BALB/C mice. Moreover, the hepatoprotective effect of SFN on triptolide-induced liver injury was associated with the activation of Nrf2 and its downstream targets. Collectively, these results indicate that Nrf2 activation protects against triptolide-induced hepatotoxicity.

  15. Integrated crop protection as a system approach

    NARCIS (Netherlands)

    Haan, de J.J.; Wijnands, F.G.; Sukkel, W.

    2005-01-01

    New farming systems in vegetable production are required as demands for high quality products that do not pollute the environment are rising, and production risks are large and incomes low. The methodology of prototyping new systems is described, especially the themes, parameters and target values

  16. Understanding of radiation protection in medicine. Pt. 2. Occupational exposure and system of radiation protection

    International Nuclear Information System (INIS)

    Iida, Hiroji; Yamamoto, Tomoyuki; Shimada, Yasuhiro

    1997-01-01

    Using a questionnaire we investigated whether radiation protection is correctly understood by medical doctors (n=140) and nurses (n=496). Although medical exposure is usually understood by medical doctors and dentists, their knowledge was found to be insufficient. Sixty-eight percent of medical doctors and 50% of dentists did not know about the system of radiation protection. Dose monitoring was not correctly carried out by approximately 20% of medical staff members, and medical personnel generally complained of anxiety about occupational exposure rather than medical exposure. They did not receive sufficient education on radiation exposure and protection in school. In conclusion, the results of this questionnaire suggested that they do not have adequate knowledge about radiation exposure and protection. The lack of knowledge about protection results in anxiety about exposure. To protect oneself from occupational exposure, individual radiation doses must be monitored, and medical practice should be reconsidered based on the results of monitoring. To eliminate unnecessary medical and occupational exposure and to justify practices such as radiological examinations, radiation protection should be well understood and appropriately carried out by medical doctors and dentists. Therefore, the education of medical students on the subject of radiation protection is required as is postgraduate education for medical doctors, dentists and nurses. (author)

  17. Management information systems for environmental compliance activities

    Energy Technology Data Exchange (ETDEWEB)

    1990-04-23

    The Department of Energy (DOE) is subject to Federal and state laws designed to protect against threats to public health and the environment. The purpose of this audit was to determine whether the Department had developed adequate information systems for tracking and reporting on the status of its compliance with these laws. Systems used for prioritizing and budgeting for environmental activities are being addressed in a separate review.

  18. Kinetic Integrated Thermal Protection System (KnITPS)

    Data.gov (United States)

    National Aeronautics and Space Administration — Use the flexibility and shape formation possibilities inherent in knitting to form thermal protection systems that can be custom fitted to a heat shield carrier...

  19. NDE for Ablative Thermal Protection Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This program addresses the need for non-destructive evaluation (NDE) methods for quality assessment and defect evaluation of thermal protection systems (TPS),...

  20. NDE for Ablative Thermal Protection Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This program addresses the need for non-destructive evaluation (NDE) methods for quality assessment and defect evaluation of thermal protection systems (TPS). Novel...

  1. Thermal Protection System Materials (TPSM): 3D MAT

    Data.gov (United States)

    National Aeronautics and Space Administration — The 3D MAT Project seeks to design and develop a game changing Woven Thermal Protection System (TPS) technology tailored to meet the needs of the Orion Multi-Purpose...

  2. Short circuit protection for a power distribution system

    Science.gov (United States)

    Owen, J. R., III

    1969-01-01

    Sensing circuit detects when the output from a matrix is present and when it should be present. The circuit provides short circuit protection for a power distribution system where the selection of the driven load is accomplished by digital logic.

  3. CNSS: Interagency Partnering to Protect Our National Security Systems

    National Research Council Canada - National Science Library

    Grimes, John G

    2008-01-01

    .... The CNSS performs the vital function of mobilizing the full, interagency National Security Community for the protection of telecommunications and information systems that support U.S. national security...

  4. Monitoring, control and protection of interconnected power systems

    CERN Document Server

    Häger, Ulf; Voropai, Nikolai

    2014-01-01

    This book presents new tools and methods for monitoring, control and protection of large scale power systems, adapting Smart Grid technologies based on wide area data exchange in combination with modern measurement devices and advanced network controllers.

  5. A control system of radiation protection at HESYRL

    International Nuclear Information System (INIS)

    Li Yuxiong; Li Juexin; Ning Xinquan

    1990-01-01

    A control system for radiation protection at Hefei National Synchrotron Radiation Laboratory (HESYRL) consists of three parts. They are a personal radiation safety interlock system, an automatic environmental radiation monitoring system and a data logging and management system for area radiation monitoring. Two-year operating experiments have shown that this system is reasonably designed, reliable, high-sensitive and automatic. The design principle, construction and operating status of each part of the system are introduced

  6. Control rod blow out protection system

    International Nuclear Information System (INIS)

    Dietrich, J.R.; Flinn, W.S.; Groves, M.D.

    1976-01-01

    A control system is described which is comprised of a plurality of low worth absorber elements with individual hydraulic actuator assemblies, positioned within the reactor vessel. Axial distortions and safety hazards are minimized by this arrangement. (E.C.B.)

  7. PAYROLL SYSTEM AND SOCIAL PROTECTION IN GERMANY

    Directory of Open Access Journals (Sweden)

    NĂSTASIE MIHAELA – ANDREEA

    2015-03-01

    Full Text Available Any payment system must establish a connection between the entity and the revenue performance of employees between the financial balance of the entity and needs to satisfy some needs of the individuals. A goal is not always easy to follow is to establish fairness in the workplace in relation to the report results. Even if the system is a fair wage, it is necessary that employees perceive and understand this. German economic success was achieved thanks to a competent management and an effort from employees, which is characterized by more order, competent and highly skilled, resulting in a competition between the management and the german economy. German management uses the tools of the pay system and the welfare system.

  8. Fixed-site physical protection system modeling

    International Nuclear Information System (INIS)

    Chapman, L.D.

    1975-01-01

    An evaluation of a fixed-site safeguard security system must consider the interrelationships of barriers, alarms, on-site and off-site guards, and their effectiveness against a forcible adversary attack whose intention is to create an act of sabotage or theft. A computer model has been developed at Sandia Laboratories for the evaluation of alternative fixed-site security systems. Trade-offs involving on-site and off-site response forces and response times, perimeter alarm systems, barrier configurations, and varying levels of threat can be analyzed. The computer model provides a framework for performing inexpensive experiments on fixed-site security systems for testing alternative decisions, and for determining the relative cost effectiveness associated with these decision policies

  9. Penetration testing protecting networks and systems

    CERN Document Server

    Henry, Kevin M

    2012-01-01

    This book is a preparation guide for the CPTE examination, yet is also a general reference for experienced penetration testers, ethical hackers, auditors, security personnel and anyone else involved in the security of an organization's computer systems.

  10. Computer-aided protective system (CAPS)

    International Nuclear Information System (INIS)

    Squire, R.K.

    1988-01-01

    A method of improving the security of materials in transit is described. The system provides a continuously monitored position location system for the transport vehicle, an internal computer-based geographic delimiter that makes continuous comparisons of actual positions with the preplanned routing and schedule, and a tamper detection/reaction system. The position comparison is utilized to institute preprogrammed reactive measures if the carrier is taken off course or schedule, penetrated, or otherwise interfered with. The geographic locater could be an independent internal platform or an external signal-dependent system utilizing GPS, Loran or similar source of geographic information; a small (micro) computer could provide adequate memory and computational capacity; the insurance of integrity of the system indicates the need for a tamper-proof container and built-in intrusion sensors. A variant of the system could provide real-time transmission of the vehicle position and condition to a central control point for; such transmission could be encrypted to preclude spoofing

  11. Protecting solar collector systems from corrosion

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    The main cause of the reduced life of a solar heating system is corrosion of the exterior parts and the internal components. This report outlines ways of reducing the cost of solar heating by reducing the corrosion in solar heating systems, and hence increasing the system's service life. Mechanisms for corrosion are discussed: these include galvanic corrosion and crevice corrosion. Means of minimizing corrosion at the design stage are then described. Such methods, when designing the solar collector, involve ensuring proper drainage of exterior water; eliminating situations where moisture, dirt and pollutants may collect; preventing condensation inside the collector; using proper gaskets and sealants at appropriate places; and selecting optimum materials and coatings. Interior corrosion can be minimized at the design stage by choosing a good heat transfer fluid and corrosion inhibitor, in the case of systems where liquids are used; ensuring a low enough flow rate to avoid erosion; designing the system to avoid crevices; and avoiding situations where galvanic corrosion could occur. Other procedures are given for minimizing corrosion in the construction and operation of solar heating systems. 7 figs., 7 tabs.

  12. Multi Agent System Based Wide Area Protection against Cascading Events

    DEFF Research Database (Denmark)

    Liu, Zhou; Chen, Zhe; Liu, Leo

    2012-01-01

    In this paper, a multi-agent system based wide area protection scheme is proposed in order to prevent long term voltage instability induced cascading events. The distributed relays and controllers work as a device agent which not only executes the normal function automatically but also can...... the effectiveness of proposed protection strategy. The simulation results indicate that the proposed multi agent control system can effectively coordinate the distributed relays and controllers to prevent the long term voltage instability induced cascading events....

  13. Relay protection coordination with generator capability curve, excitation system limiters and power system relay protections settings

    OpenAIRE

    Buha Danilo; Buha Boško; Jačić Dušan; Gligorov Saša; Božilov Marko; Marinković Savo; Milosavljević Srđan

    2016-01-01

    The relay protection settings performed in the largest thermal powerplant (TE "Nikola Tesla B") are reffered and explained in this paper. The first calculation step is related to the coordination of the maximum stator current limiter settings, the overcurrent protection with inverse characteristics settings and the permitted overload of the generator stator B1. In the second calculation step the settings of impedance generator protection are determined, and the methods and criteria according ...

  14. The Philosophy of the New Radiation Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Wikman, P.

    2004-07-01

    The International Commission on Radiological Protection has proposed a new philosophy of radiation protection. An important component in the proposed system of protection is the principle ''If the individual is sufficiently protected from a source, then society is also protected from that source''. This principle is here analysed and found to be subject to several problems. The principle reflects the controversial ethical position that the likely harm to several people can be ignored as long as the individual risk is small. The ICRP states that the new system involves a change from a previous utilitarian ethics to an individual-oriented philosophy. It is argued that a rights-based or a duty-based ethic requires a more risk avert interpretation of when an individual is sufficiently protected than what the proposal suggests. It is concluded that the proposed principle contradicts the other important principle in the new system - the optimisation principle. Due to these problems it is suggested that the ICRP ought to discard the proposed principle from the new system of radiation protection. (Author) 7 refs.

  15. The Philosophy of the New Radiation Protection System

    International Nuclear Information System (INIS)

    Wikman, P.

    2004-01-01

    The International Commission on Radiological Protection has proposed a new philosophy of radiation protection. An important component in the proposed system of protection is the principle I f the individual is sufficiently protected from a source, then society is also protected from that source . This principle is here analysed and found to be subject to several problems. The principle reflects the controversial ethical position that the likely harm to several people can be ignored as long as the individual risk is small. The ICRP states that the new system involves a change from a previous utilitarian ethics to an individual-oriented philosophy. It is argued that a rights-based or a duty-based ethic requires a more risk avert interpretation of when an individual is sufficiently protected than what the proposal suggests. It is concluded that the proposed principle contradicts the other important principle in the new system - the optimisation principle. Due to these problems it is suggested that the ICRP ought to discard the proposed principle from the new system of radiation protection. (Author) 7 refs

  16. Fusion magnet safety studies program: superconducting magnet protection system and failure. Interim report

    International Nuclear Information System (INIS)

    Allinger, J.; Danby, G.; Hsieh, S.Y.; Keane, J.; Powell, J.; Prodell, A.

    1975-11-01

    This report includes the first two quarters study of available information on schemes for protecting superconducting magnets. These schemes can be divided into two different categories. The first category deals with the detection of faulty regions (or normal regions) in the magnet. The second category relates to the protection of the magnet when a fault is detected, and the derived signal which can be used to activate a safety system (or energy removal system). The general detection and protection methods are first described briefly and then followed by a survey of the protection systems used by different laboratories for various magnets. A survey of the cause of the magnet difficulties or failures is also included. A preliminary discussion of these protection schemes and the experimental development of this program is given

  17. Displacements of Metallic Thermal Protection System Panels During Reentry

    Science.gov (United States)

    Daryabeigi, Kamran; Blosser, Max L.; Wurster, Kathryn E.

    2006-01-01

    Bowing of metallic thermal protection systems for reentry of a previously proposed single-stage-to-orbit reusable launch vehicle was studied. The outer layer of current metallic thermal protection system concepts typically consists of a honeycomb panel made of a high temperature nickel alloy. During portions of reentry when the thermal protection system is exposed to rapidly varying heating rates, a significant temperature gradient develops across the honeycomb panel thickness, resulting in bowing of the honeycomb panel. The deformations of the honeycomb panel increase the roughness of the outer mold line of the vehicle, which could possibly result in premature boundary layer transition, resulting in significantly higher downstream heating rates. The aerothermal loads and parameters for three locations on the centerline of the windward side of this vehicle were calculated using an engineering code. The transient temperature distributions through a metallic thermal protection system were obtained using 1-D finite volume thermal analysis, and the resulting displacements of the thermal protection system were calculated. The maximum deflection of the thermal protection system throughout the reentry trajectory was 6.4 mm. The maximum ratio of deflection to boundary layer thickness was 0.032. Based on previously developed distributed roughness correlations, it was concluded that these defections will not result in tripping the hypersonic boundary layer.

  18. 76 FR 36863 - Special Conditions: Gulfstream Model GVI Airplane; Electronic Systems Security Protection From...

    Science.gov (United States)

    2011-06-23

    ... Security Protection From Unauthorized External Access AGENCY: Federal Aviation Administration (FAA), DOT... for Gulfstream GVI airplanes. 1. The applicant must ensure electronic system security protection for... that effective electronic system security protection strategies are implemented to protect the airplane...

  19. Reliability analysis of reactor protection systems

    International Nuclear Information System (INIS)

    Alsan, S.

    1976-07-01

    A theoretical mathematical study of reliability is presented and the concepts subsequently defined applied to the study of nuclear reactor safety systems. The theory is applied to investigations of the operational reliability of the Siloe reactor from the point of view of rod drop. A statistical study conducted between 1964 and 1971 demonstrated that most rod drop incidents arose from circumstances associated with experimental equipment (new set-ups). The reliability of the most suitable safety system for some recently developed experimental equipment is discussed. Calculations indicate that if all experimental equipment were equipped with these new systems, only 1.75 rod drop accidents would be expected to occur per year on average. It is suggested that all experimental equipment should be equipped with these new safety systems and tested every 21 days. The reliability of the new safety system currently being studied for the Siloe reactor was also investigated. The following results were obtained: definite failures must be detected immediately as a result of the disturbances produced; the repair time must not exceed a few hours; the equipment must be tested every week. Under such conditions, the rate of accidental rod drops is about 0.013 on average per year. The level of nondefinite failures is less than 10 -6 per hour and the level of nonprotection 1 hour per year. (author)

  20. Deicing System Protects General Aviation Aircraft

    Science.gov (United States)

    2007-01-01

    Kelly Aerospace Thermal Systems LLC worked with researchers at Glenn Research Center on deicing technology with assistance from the Small Business Innovation Research (SBIR) program. Kelly Aerospace acquired Northcoast Technologies Ltd., a firm that had conducted work on a graphite foil heating element under a NASA SBIR contract and developed a lightweight, easy-to-install, reliable wing and tail deicing system. Kelly Aerospace engineers combined their experiences with those of the Northcoast engineers, leading to the certification and integration of a thermoelectric deicing system called Thermawing, a DC-powered air conditioner for single-engine aircraft called Thermacool, and high-output alternators to run them both. Thermawing, a reliable anti-icing and deicing system, allows pilots to safely fly through ice encounters and provides pilots of single-engine aircraft the heated wing technology usually reserved for larger, jet-powered craft. Thermacool, an innovative electric air conditioning system, uses a new compressor whose rotary pump design runs off an energy-efficient, brushless DC motor and allows pilots to use the air conditioner before the engine even starts

  1. Fire protection in ventilation systems and in case of fire operating ventilation systems

    International Nuclear Information System (INIS)

    Zitzelsberger, J.

    1983-01-01

    The fire risks in ventilation systems are discussed. It follows a survey of regulations on fire prevention and fire protection in ventilation systems and smoke and heat exhaust systems applicable to nuclear installations in the Federal Republic of Germany. Fire protection concepts for normal systems and for systems operating also in case of fire will be given. Several structural elements for fire protection in those systems will be illustrated with regard to recent research findings

  2. 14 CFR 25.1316 - System lightning protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false System lightning protection. 25.1316... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1316 System lightning... systems to perform these functions are not adversely affected when the airplane is exposed to lightning...

  3. TLA monitoring of an anodic protection system

    International Nuclear Information System (INIS)

    Wallace, G.; Boulton, H.

    1992-01-01

    Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this activity, it is possible to calculate how much of the surface has been removed by corrosion. 14 refs., 7 figs., 4 tabs

  4. Adaptive Protection Scheme for a Distribution System Considering Grid-Connected and Islanded Modes of Operation

    Directory of Open Access Journals (Sweden)

    Yavuz Ates

    2016-05-01

    Full Text Available The renewable energy-based distributed generation (DG implementation in power systems has been an active research area during the last few decades due to several environmental, economic and political factors. Although the integration of DG offers many advantages, several concerns, including protection schemes in systems with the possibility of bi-directional power flow, are raised. Thus, new protection schemes are strongly required in power systems with a significant presence of DG. In this study, an adaptive protection strategy for a distribution system with DG integration is proposed. The proposed strategy considers both grid-connected and islanded operating modes, while the adaptive operation of the protection is dynamically realized considering the availability of DG power production (related to faults or meteorological conditions in each time step. Besides, the modular structure and fast response of the proposed strategy is validated via simulations conducted on the IEEE 13-node test system.

  5. 75 FR 68370 - Agency Information Collection Activities: Office of Infrastructure Protection; Chemical Security...

    Science.gov (United States)

    2010-11-05

    ... DEPARTMENT OF HOMELAND SECURITY National Protection and Programs Directorate [Docket No. DHS-2010-0071] Agency Information Collection Activities: Office of Infrastructure Protection; Chemical Security...: The Department of Homeland Security (DHS), National Protection and Programs Directorate (NPPD), Office...

  6. ELECTRONIC PAYMENT SYSTEM AND ITS PROTECTION

    Directory of Open Access Journals (Sweden)

    Miroslav Milutinovic

    2015-01-01

    Full Text Available All developed countries are in transition from the IT economy to a web economy - the biggest technological innovation that will have a long-term positive effect on the formation of the economic growth rate, the major structural changes and on the differentiated effects on the economic areas that are, at a faster or a slower rate, being included in this technological change. The electronic commerce or e-commerce has a huge potential for development. The electronic commerce between the companies (B-2-B is significantly greater compared to retail electronic commerce (B-2-C. In both spheres of trade, the Internet is used as a platform for the transfer of information and for concluding business deals. Market economy requires Accelerated Payment Processing which is achieved by introducing and improving the electronic payment procedures. There is an emphasized dichotomy between the two spheres of the payment system: large-value and small-value payments. The large value payment systems can be described as the arteries of the payment system, and the small-value transfer systems as a complex network of veins that bind the entire economy.

  7. Lightning protecting materials used on radar system

    NARCIS (Netherlands)

    Blaj, M.A.; Damstra, Geert C.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2009-01-01

    Because of the extensive use in modern systems of very sensitive electronic components, lightning strikes does not represent only a threat, but something that cannot be neglected anymore and safety hazards caused by direct and indirect lightning to the aircraft or naval industry. Everyday new

  8. Jamming protection of spread spectrum RFID system

    Science.gov (United States)

    Mazurek, Gustaw

    2006-10-01

    This paper presents a new transform-domain processing algorithm for rejection of narrowband interferences in RFID/DS-CDMA systems. The performance of the proposed algorithm has been verified via computer simulations. Implementation issues have been discussed. The algorithm can be implemented in the FPGA or DSP technology.

  9. Problems of Financing Water Protection and Water Management Activities in the Republic of Buryatia

    Directory of Open Access Journals (Sweden)

    Dondyukov Z. B.-D.

    2010-06-01

    Full Text Available The development of the payment system for using water objects in the Russian Federation is studied. The problem of insufficient financing the water protection and water management activities in the Republic of Buryatia under conditions of active environmental restrictions of the Baikal natural area is revealed. The necessity for amendments in Russia’s budget legislation concerning water tax and charges for using water objects is substantiated and relevant proposals are made

  10. Illustration of distributed generation effects on protection system coordination

    Science.gov (United States)

    Alawami, Hussain Adnan

    Environmental concerns, market forces, and emergence of new technologies have recently resulted in restructuring electric utility from vertically integrated networks to competitive deregulated entities. Distributed generation (DG) is playing a major role in such deregulated markets. When they are installed in small amounts and small sizes, their impacts on the system may be negligible. When their penetration levels increase as well as their sizes, however, they may start affecting the system performance from more than one aspect. Power system protection needs to be re-assessed after the emergence of DG. This thesis attempts to illustrate the impact of DG on the power system protection coordination. It will study the operation of the impedance relays, fuses, reclosers and overcurrent relays when a DG is added to the distribution network. Different DG sizes, distances from the network and locations within the distribution system will be considered. Power system protection coordination is very sensitive to the DG size where it is not for the DG distance. DG location has direct impact on the operation of the protective devices especially when it is inserted in the middle point of the distribution system. Key Words, Distributed Generation, Impedance relay, fuses, reclosers, overcurrent relays, power system protection coordination.

  11. Implementation of FPGA-Based Diverse Protection System

    International Nuclear Information System (INIS)

    Hwang, Soo Yun; Lee, Yoon Hee; Shon, Se Do; Baek, Seung Min

    2015-01-01

    Obsolete analog and digital hardware platforms in NPPs are commonly replaced with programmable logic controller (PLC) and distributed control system (DCS). Field programmable gate arrays (FPGAs) are highlighted as an alternative to obsolete hardware platforms. FPGAs are digital integrated circuits (ICs) that contain the configurable (programmable) blocks of logic along with configurable interconnections among these blocks. Designers can configure (program) such devices to perform a tremendous variety of tasks. FPGAs have been evolved from the technology of programmable logic device (PLD). Nowadays, they can contain millions of logic gates by nanotechnology and can be used to implement extremely large and complex functions that previously could be realized only using application specific integrated circuits (ASICs). This paper presents the implementation of an FPGA-based diverse protection system (DPS) which executes the protective functions in NPP when the protective functions of the plant protection system (PPS) fails

  12. Implementation of FPGA-Based Diverse Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Soo Yun; Lee, Yoon Hee; Shon, Se Do; Baek, Seung Min [KEPCO Engineering and Construction Company Inc., Daejeon (Korea, Republic of)

    2015-10-15

    Obsolete analog and digital hardware platforms in NPPs are commonly replaced with programmable logic controller (PLC) and distributed control system (DCS). Field programmable gate arrays (FPGAs) are highlighted as an alternative to obsolete hardware platforms. FPGAs are digital integrated circuits (ICs) that contain the configurable (programmable) blocks of logic along with configurable interconnections among these blocks. Designers can configure (program) such devices to perform a tremendous variety of tasks. FPGAs have been evolved from the technology of programmable logic device (PLD). Nowadays, they can contain millions of logic gates by nanotechnology and can be used to implement extremely large and complex functions that previously could be realized only using application specific integrated circuits (ASICs). This paper presents the implementation of an FPGA-based diverse protection system (DPS) which executes the protective functions in NPP when the protective functions of the plant protection system (PPS) fails.

  13. The protection of photovoltaic power systems from lightning

    Science.gov (United States)

    Rogers, C. B.

    Lightning protection techniques at nine prototype photovoltaic power system sites with outputs from 18-225 kW are described. Noting that protection schemes are devised to fit isokeraunic data for specific sites, grounding is cited as a common feature for all systems. The grounds are, in separate instances, connected to junction boxes, frames of the solar cell panels, lead from the dc center, from the dc negative terminal, from the frames and equipment, at the array turntable, or from the building rebar frames. The dc power cables are protected by either metal conduit, metal conduit ground wire, direct burial, by rigid metal conduit, ground conductors, or by ground conductors at the ends of the conduit run. Costs run from 0.01-0.28$/W, with all the systems outfitted with bypass and blocking diodes. Direct stroke protection is viewed as less important than isokeraunic data.

  14. New Protective Measures for Cooling Systems

    International Nuclear Information System (INIS)

    Carter, D. Anthony; Nonohue, Jonh M.

    1974-01-01

    Cooling water treatments have been updated and improved during the last few years. Particularly important are the nontoxic programs which conform plant cooling water effluents to local water quality standards without expenditures for capital equipment. The relationship between scaling and corrosion in natural waters has been recognized for many years. This relationship is the basis for the Langelier Saturation Index control method which was once widely applied to reduce corrosion in cooling water systems. It used solubility characteristics to maintain a very thin deposit on metal surfaces for preventing corrosion. This technique was rarely successful. That is, the solubility of calcium carbonate and most other inorganic salts depends on temperature. If good control exists on cold surfaces, excessive deposition results on the heat transfer tubes. Also, because water characteristic normally vary in a typical cooling system, precise control of scaling at both hot and cold surfaces is virtually impossible

  15. Cooling system with automated seasonal freeze protection

    Science.gov (United States)

    Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth, Jr., Michael J.; Iyengar, Madhusudan K.; Simons, Robert E.; Singh, Prabjit; Zhang, Jing

    2016-05-24

    An automated multi-fluid cooling system and method are provided for cooling an electronic component(s). The cooling system includes a coolant loop, a coolant tank, multiple valves, and a controller. The coolant loop is at least partially exposed to outdoor ambient air temperature(s) during normal operation, and the coolant tank includes first and second reservoirs containing first and second fluids, respectively. The first fluid freezes at a lower temperature than the second, the second fluid has superior cooling properties compared with the first, and the two fluids are soluble. The multiple valves are controllable to selectively couple the first or second fluid into the coolant in the coolant loop, wherein the coolant includes at least the second fluid. The controller automatically controls the valves to vary first fluid concentration level in the coolant loop based on historical, current, or anticipated outdoor air ambient temperature(s) for a time of year.

  16. A critical review of the system of radiation protection

    International Nuclear Information System (INIS)

    2000-01-01

    Our modern, information society is increasingly interested in transparency and participation in many aspects of government, and this is particularly true in areas involving public health and environmental protection. Radiation protection is no exception to this trend. Scientific rationale that was once sufficient to explain radiation protection theory and practice is no longer adequate. The need to address and communicate theory, practice and the decision-making process to a wider audience has given rise to numerous debates and led the radiation protection community to revisit the framework of the system of radiation protection. The very fundamentals of the system of radiation protection continue to be questioned in a healthy fashion, and many aspects have been identified which could better serve stakeholders given some additional thought in the light of modern societal needs. This report is the summary of the NEA's first reflections in this area, and describes those aspects of the current international system of radiation protection that could be improved. Suggested directions for improvement are provided. (author)

  17. A Fall Protection System for High-Rise Construction

    Directory of Open Access Journals (Sweden)

    Haluk Çeçen

    2013-01-01

    Full Text Available In construction industry, the number of fatal and nonfatal occupational injuries is higher than other industries. Among causes of these accidents, “falls” play a key role. This situation reveals the importance for carrying out research in fall protection systems. In this paper, a practical, economical, and functional fall protection system is introduced. Following determination and evaluation of existing solutions, weekly brainstorming meetings were held among the responsible project staff (general coordinator, project coordinator, project manager, site manager, and health and safety manager. As a result of these meetings, design criteria were developed. Based on these criteria, the fall protection system for high-rise construction (FPSFHC was developed which satisfied all the specified design criteria. Required materials were procured from local dealers. In this paper, criteria used in design and details of the final design are presented. Field performance of the system is evaluated, and recommendations for further development and standardization of the system are added.

  18. Protective, Modular Wave Power Generation System

    Energy Technology Data Exchange (ETDEWEB)

    Vvedensky, Jane M.; Park, Robert Y.

    2012-11-27

    The concept of small wave energy conversion modules that can be built into large, scalable arrays, in the same vein as solar panels, has been developed. This innovation lends itself to an organic business and development model, and enables the use of large-run manufacturing technology to reduce system costs. The first prototype module has been built to full-scale, and tested in a laboratory wave channel. The device has been shown to generate electricity and dissipate wave energy. Improvements need to be made to the electrical generator and a demonstration of an array of modules should be made in natural conditions.

  19. Medical Provider Ballistic Protection at Active Shooter Events.

    Science.gov (United States)

    Stopyra, Jason P; Bozeman, William P; Callaway, David W; Winslow, James; McGinnis, Henderson D; Sempsrott, Justin; Evans-Taylor, Lisa; Alson, Roy L

    2016-01-01

    There is some controversy about whether ballistic protective equipment (body armor) is required for medical responders who may be called to respond to active shooter mass casualty incidents. In this article, we describe the ongoing evolution of recommendations to optimize medical care to injured victims at such an incident. We propose that body armor is not mandatory for medical responders participating in a rapid-response capacity, in keeping with the Hartford Consensus and Arlington Rescue Task Force models. However, we acknowledge that the development and implementation of these programs may benefit from the availability of such equipment as one component of risk mitigation. Many police agencies regularly retire body armor on a defined time schedule before the end of its effective service life. Coordination with law enforcement may allow such retired body armor to be available to other public safety agencies, such as fire and emergency medical services, providing some degree of ballistic protection to medical responders at little or no cost during the rare mass casualty incident. To provide visual demonstration of this concept, we tested three "retired" ballistic vests with ages ranging from 6 to 27 years. The vests were shot at close range using police-issue 9mm, .40 caliber, .45 caliber, and 12-gauge shotgun rounds. Photographs demonstrate that the vests maintained their ballistic protection and defeated all of these rounds. 2016.

  20. Activities of Protection against Ionizing Radiation in Niger

    International Nuclear Information System (INIS)

    Kando Hamadou, M.

    2008-01-01

    Niger, sahelian country of Western Africa, is limited to North by Libya and Algeria, to the South by Nigeria and the Benin, to the East by Chad and the West by Mali and Burkina Faso. It covers a surface of 1 267 000 km2 and has a population of approximately 12 000 000 inhabitants. Niger is a large uranium producer with two extraction and treatment development companies of uranium ore which are the company of the mines of Air (SOMAIR) created in 1971 and the mining company of Akouta (COMINAK) created in 1978. Beyond the mining sector, ionizing radiation sources are used in the fields of industry, health, teaching and research. The first lawful text of protection against ionizing radiation was signed on December 5, 1979 and specifically related to the mining activities of uranium. With the multiform assistance of International Atomic Energy Agency (IAEA) protection against radiation knew a significant evolution. A national centre of protection against radiation was created in 1998, two laws relating to the field were adopted in June 2006 and three lawful texts of application of these laws are in the process of finalization

  1. Protected areas in tropical Africa: assessing threats and conservation activities.

    Science.gov (United States)

    Tranquilli, Sandra; Abedi-Lartey, Michael; Abernethy, Katharine; Amsini, Fidèle; Asamoah, Augustus; Balangtaa, Cletus; Blake, Stephen; Bouanga, Estelle; Breuer, Thomas; Brncic, Terry M; Campbell, Geneviève; Chancellor, Rebecca; Chapman, Colin A; Davenport, Tim R B; Dunn, Andrew; Dupain, Jef; Ekobo, Atanga; Eno-Nku, Manasseh; Etoga, Gilles; Furuichi, Takeshi; Gatti, Sylvain; Ghiurghi, Andrea; Hashimoto, Chie; Hart, John A; Head, Josephine; Hega, Martin; Herbinger, Ilka; Hicks, Thurston C; Holbech, Lars H; Huijbregts, Bas; Kühl, Hjalmar S; Imong, Inaoyom; Yeno, Stephane Le-Duc; Linder, Joshua; Marshall, Phil; Lero, Peter Minasoma; Morgan, David; Mubalama, Leonard; N'Goran, Paul K; Nicholas, Aaron; Nixon, Stuart; Normand, Emmanuelle; Nziguyimpa, Leonidas; Nzooh-Dongmo, Zacharie; Ofori-Amanfo, Richard; Ogunjemite, Babafemi G; Petre, Charles-Albert; Rainey, Hugo J; Regnaut, Sebastien; Robinson, Orume; Rundus, Aaron; Sanz, Crickette M; Okon, David Tiku; Todd, Angelique; Warren, Ymke; Sommer, Volker

    2014-01-01

    Numerous protected areas (PAs) have been created in Africa to safeguard wildlife and other natural resources. However, significant threats from anthropogenic activities and decline of wildlife populations persist, while conservation efforts in most PAs are still minimal. We assessed the impact level of the most common threats to wildlife within PAs in tropical Africa and the relationship of conservation activities with threat impact level. We collated data on 98 PAs with tropical forest cover from 15 countries across West, Central and East Africa. For this, we assembled information about local threats as well as conservation activities from published and unpublished literature, and questionnaires sent to long-term field workers. We constructed general linear models to test the significance of specific conservation activities in relation to the threat impact level. Subsistence and commercial hunting were identified as the most common direct threats to wildlife and found to be most prevalent in West and Central Africa. Agriculture and logging represented the most common indirect threats, and were most prevalent in West Africa. We found that the long-term presence of conservation activities (such as law enforcement, research and tourism) was associated with lower threat impact levels. Our results highlight deficiencies in the management effectiveness of several PAs across tropical Africa, and conclude that PA management should invest more into conservation activities with long-term duration.

  2. Protected areas in tropical Africa: assessing threats and conservation activities.

    Directory of Open Access Journals (Sweden)

    Sandra Tranquilli

    Full Text Available Numerous protected areas (PAs have been created in Africa to safeguard wildlife and other natural resources. However, significant threats from anthropogenic activities and decline of wildlife populations persist, while conservation efforts in most PAs are still minimal. We assessed the impact level of the most common threats to wildlife within PAs in tropical Africa and the relationship of conservation activities with threat impact level. We collated data on 98 PAs with tropical forest cover from 15 countries across West, Central and East Africa. For this, we assembled information about local threats as well as conservation activities from published and unpublished literature, and questionnaires sent to long-term field workers. We constructed general linear models to test the significance of specific conservation activities in relation to the threat impact level. Subsistence and commercial hunting were identified as the most common direct threats to wildlife and found to be most prevalent in West and Central Africa. Agriculture and logging represented the most common indirect threats, and were most prevalent in West Africa. We found that the long-term presence of conservation activities (such as law enforcement, research and tourism was associated with lower threat impact levels. Our results highlight deficiencies in the management effectiveness of several PAs across tropical Africa, and conclude that PA management should invest more into conservation activities with long-term duration.

  3. Study on pulsed current cathodic protection in a simulated system

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Milin; Li, Helin [Xi' an Jiao Tong Universitiy (China)]|[Tubular Goods Research Center of China National Petroleum Corp. (China); Qiu, Yubing; Guo, Xingpeng [Hua Zhong University of Science and Techonology (China)

    2004-07-01

    The pulsed current cathodic protection (PCCP) is a new cathodic protection (CP) technology and shows more advantages over the conventional DC cathodic protection (DCCP) in oil well casing system. However, little information about PCCP is reported. In this research, a simulated CP system was set up in a pool of 3.5 m x 2.0 m x 3.0 m size, in which the effects of the square wave pulsed current (SWPC) parameters (amplitude: IA, frequency: f, duty cycle: P), auxiliary anode distance (d) and media conductivity ({mu}) on the cathodic potential (E) distribution were studied, and the protection effects of PCCP and DCCP were compared. The results show that with increase of the square wave parameters (IA, f, P), the E distribution becomes more negative and the effects of each current parameter are relate closely to the cathode polarizing state. Only with suitable square wave parameters can the whole cathode be effectively protected. With increase of d and {mu}, the E distribution becomes more uniform. Compared with DCCP system, PCCP system has much more uniform E distribution, costs less average current, and gains much better protection effects. Further, the mechanism of PCCP was analyzed. (authors)

  4. Electrical protection of superconducting magnet systems

    International Nuclear Information System (INIS)

    Sutter, D.F.; Flora, R.H.

    1975-01-01

    The problem of dissipating the energy stored in the field of a superconducting magnet when a quench occurs has received considerable study. However, when the magnet becomes a system 4 miles in length whose normal operation is an ac mode, some re-examination of standard techniques for dissipating energy outside the magnets is in order. Data accumulated in the Fermilab Energy Doubler magnet development program shows that heating associated with the temporal and spatial development of quenches is highly localized and can result in temperatures damaging to the superconducting wire. The design and operation are discussed for several energy dumping schemes, compatible with the operation of ac superconducting magnets, wherein more than 70 percent of the stored energy can be dissipated outside the magnet. Instrumentation to detect quenches early in their development and circuits for dumping the field energy are described, and representative operating performance data for the dump circuits and data showing temporal development of quenches are presented. (auth)

  5. Enhancement of observability and protection of smart power system

    Science.gov (United States)

    Siddique, Abdul Hasib

    It is important for a modern power grid to be smarter in order to provide reliable and sustainable supply of electricity. Traditional way of receiving data from the wired system is a very old and outdated technology. For a quicker and better response from the electric system, it is important to look at wireless systems as a feasible option. In order to enhance the observability and protection it is important to integrate wireless technology with the modern power system. In this thesis, wireless network based architecture for wide area monitoring and an alternate method for performing current measurement for protection of generators and motors, has been adopted. There are basically two part of this project. First part deals with the wide area monitoring of the power system and the second part focuses more on application of wireless technology from the protection point of view. A number of wireless method have been adopted in both the part, these includes Zigbee, analog transmission (Both AM and FM) and digital transmission. The main aim of our project was to propose a cost effective wide area monitoring and protection method which will enhance the observability and stability of power grid. A new concept of wireless integration in the power protection system has been implemented in this thesis work.

  6. [Anti-Candida activity of aroma candy and its protective activity against murine oral candidiasis].

    Science.gov (United States)

    Hayama, Kazumi; Takahashi, Miki; Suzuki, Motofumi; Ezawa, Kunio; Yamazaki, Masatoshi; Matsukawa, Taiji; Kishi, Akinobu; Sato, Nobuya; Abe, Shigeru

    2015-01-01

    A daily eatable candy that has possible protective activity against oral candidiasis was experimentally produced. The candy was made from reduced-maltose as main constituent and from several natural products, such as oligonol (depolymerized polyphenols derived from lychee), cinnamon (cassia), citral, and capric acid, which are known to have anti-Candida activity in vitro and in vivo. The candy effectively inhibited the mycelial growth of C. albicans, even when it was diluted 1,000 times with culture media. We assessed the protective activity of the candy against murine candidiasis. When 50μl of candy dissolved and diluted 4 times with water was administered 3 times into the oral cavity of Candida infected mice, the score of lesions on the Candida-infected tongues improved on day 2. These findings suggest that this candy has potential as food that provides protective activity against oral candidiasis.

  7. Protective barrier systems for final disposal of Hanford Waste Sites

    International Nuclear Information System (INIS)

    Phillips, S.J.; Hartley, J.N.

    1986-01-01

    A protecting barrier system is being developed for potential application in the final disposal of defense wastes at the Hanford Site. The functional requirements for the protective barrier are control of water infiltration, wind erosion, and plant and animal intrusion into the waste zone. The barrier must also be able to function without maintenance for the required time period (up to 10,000 yr). This paper summarizes the progress made and future plans in this effort to design and test protective barriers at the Hanford Site

  8. Reactor protection systems for the Replacement Research Reactor, ANSTO

    International Nuclear Information System (INIS)

    Morris, C.R.

    2003-01-01

    The 20-MW Replacement Research Reactor Project which is currently under construction at ANSTO will have a combination of a state of the art triplicated computer based reactor protection system, and a fully independent, and diverse, triplicated analogue reactor protection system, that has been in use in the nuclear industry, for many decades. The First Reactor Protection System (FRPS) consists of a Triconex triplicated modular redundant system that has recently been approved by the USNRC for use in the USA?s power reactor program. The Second Reactor Protection System is a hardwired analogue system supplied by Foxboro, the Spec 200 system, which is also Class1E qualified. The FRPS is used to drop the control rods when its safety parameter setpoints have been reached. The SRPS is used to drain the reflector tank and since this operation would result in a reactor poison out due to the time it would take to refill the tank the FRPS trip setpoints are more limiting. The FRPS and SRPS have limited hardwired indications on the control panels in the main control room (MCR) and emergency control centre (ECC), however all FRPS and SRPS parameters are capable of being displayed on the reactor control and monitoring system (RCMS) video display units. The RCMS is a Foxboro Series I/A control system which is used for plant control and monitoring and as a protection system for the cold neutron source. This paper will provide technical information on both systems, their trip logics, their interconnections with each other, and their integration into the reactor control and monitoring system and control panels. (author)

  9. A machine protection beam position monitor system

    International Nuclear Information System (INIS)

    Medvedko, E.; Smith, S.; Fisher, A.

    1998-01-01

    Loss of the stored beam in an uncontrolled manner can cause damage to the PEP-II B Factory. We describe here a device which detects large beam position excursions or unexpected beam loss and triggers the beam abort system to extract the stored beam safely. The bad-orbit abort trigger beam position monitor (BOAT BPM) generates a trigger when the beam orbit is far off the center (>20 mm), or rapid beam current loss (dI/dT) is detected. The BOAT BPM averages the input signal over one turn (136 kHz). AM demodulation is used to convert input signals at 476 MHz to baseband voltages. The detected signal goes to a filter section for suppression of the revolution frequency, then on to amplifiers, dividers, and comparators for position and current measurements and triggering. The derived current signal goes to a special filter, designed to perform dI/dT monitoring at fast, medium, and slow current loss rates. The BOAT BPM prototype test results confirm the design concepts. copyright 1998 American Institute of Physics

  10. Railway automatic safety protection system based on GPS

    Directory of Open Access Journals (Sweden)

    Fu Hai Juan

    2016-01-01

    Full Text Available The automatic protection system of railway safety is designed for the railway construction workers to protect alarm, and the safety protection device by using GPS satellite positioning system to acquire location information of the operating point, through the CTC/TDCS system and computer monitoring system for the running of the train position and the arithmetic distance. Achieving timely and continuously forecasts about the distance of the train which is apart from the operating point to prompt the voice alarm of the approaching train. Using digital technology to realize the function of the traditional analog interphone, eliminates the quality problems of the call. With the GSM-R, mobile wireless transmission channel and terminal technology, it overcomes the restrictions of the analog interphone which influenced by communication distance and more problems of blind areas. Finally to achieve practical, convenient, applicable and adaptable design goals.

  11. Study of Physical Protection System at PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Ligam, A.S.; Ina, I.; Zarina Masood

    2016-01-01

    Physical protection program at PUSPATI TRIGA Reactor (RTP) which is located at Nuklear Malaysia, Bangi Complex has been strengthened and upgraded from time to time to accommodate current situation needs. However, there is always room for improvement. Hence, study have been made to look deeper into physical protection components such as delay systems, external sensors, PPS intruder alarm sensors, use of video system, personnel security or insider threats, access control operation system operation rules and security culture that may need to take into consideration. (author)

  12. Information support systems for cultural heritage protection against flooding

    Directory of Open Access Journals (Sweden)

    K. Nedvedova

    2015-08-01

    Full Text Available The goal of this paper is to present use of different kind of software applications to create complex support system for protection of cultural heritage against flooding. The project is very complex and it tries to cover the whole area of the problem from prevention to liquidation of aftermath effects. We used GIS for mapping the risk areas, ontology systems for vulnerability assessment application and the BORM method (Business Object Relation Modelling for flood protection system planning guide. Those modern technologies helped us to gather a lot of information in one place and provide the knowledge to the broad audience.

  13. Alternative High Performance Polymers for Ablative Thermal Protection Systems

    Science.gov (United States)

    Boghozian, Tane; Stackpoole, Mairead; Gonzales, Greg

    2015-01-01

    Ablative thermal protection systems are commonly used as protection from the intense heat during re-entry of a space vehicle and have been used successfully on many missions including Stardust and Mars Science Laboratory both of which used PICA - a phenolic based ablator. Historically, phenolic resin has served as the ablative polymer for many TPS systems. However, it has limitations in both processing and properties such as char yield, glass transition temperature and char stability. Therefore alternative high performance polymers are being considered including cyanate ester resin, polyimide, and polybenzoxazine. Thermal and mechanical properties of these resin systems were characterized and compared with phenolic resin.

  14. Motor drive chassis for the plutonium protection system

    International Nuclear Information System (INIS)

    Shaut, A.L.

    1979-05-01

    A motor drive chassis has been developed for use in the Plutonium Protection System. Rotation of the desired carrousel in a secure storage module is controlled by this chassis which supplies the power and drive pulses required by the carrousel motor. This work was sponsored by the Department of Energy/Office of Safeguards and Security (DOE/OSS) as part of the overall Sandia Fixed Physical Protection Program

  15. Radiological protection in two types of human activities and from potential exposure

    International Nuclear Information System (INIS)

    Li Deping

    1991-01-01

    The new ICPR recommendations emphasize the distinction in radiological protection in two different types of human activities, practice and intervention. The purpose of emphases and measures for controlling or reduction of exposure for each type of activity are discussed. Potential exposure is regarded as an part of radiological protection system in this new recommendations, in a practice, it can be significantly reduced by proper prevention and mitigation measures in design and management. It is pointed out that with modern safety technology, the probability of potential exposure situations can be lowered to many orders of magnitude, even though the estimated value of probability is not accurate. Situations requiring intervention and the principles in protection are also discussed

  16. Report on radiation protection calibration activities in Australia

    International Nuclear Information System (INIS)

    Hargrave, N.J.

    1995-01-01

    Australia is a federation of eight autonomous States or Territories. Each of these is responsible for many matters including radiation safety within their borders. National matters are the responsibility of the Federal Government. The Australian Radiation Laboratory (ARL) is a part of the Federal Government Department of Human Services and Health and undertakes research and service activities related to radiation health. Work related to both ionising and non ionising radiation and regulatory matters is performed. Some of the research activities relate to radiation measurement standards, environmental radioactivity (e.g. radon in air, radioactivity in drinking water), effects of electro-magnetic fields on health (ELF), ultra violet radiation (UV) and laser safety, radiochemistry, medical applications of radiation (and doses to the population as a result), general health physics, thermoluminescent dosimetry (TLD) and electron spin resonance (ESR) dosimetry. The calibration of protection instruments are undertaken by the Ionising Radiation Standards Group within the Laboratory and by State Health Laboratories. (J.P.N.)

  17. Design of a Haptic Feedback System for Flight Envelope Protection

    NARCIS (Netherlands)

    Van Baelen, D.; Ellerbroek, J.; van Paassen, M.M.; Mulder, M.

    2018-01-01

    Current Airbus aircraft use a fly-by-wire control device: a passive spring-damper system which generates, without any force feedback, an electrical signal to the flight control computer. Additionally, a hard flight envelope protection system is used which can limit the inputs of the pilot when

  18. The use of process computers in reactor protection systems

    International Nuclear Information System (INIS)

    1973-04-01

    The report contains the papers presented at the LRA information meeting in spring 1972, concerning the use of process computers in reactor protection systems. The main interest was directed at a system conception as proposed from AEG for future BWR-plants. (orig.) [de

  19. Protection issues on microgrid/distributed generation based systems

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Angelo R. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil); Ribeiro, Paulo F. [Calvin College, Grand Rapids, MI (United States). Dept. of Electrical Engineering; Iung, Anderson M. [Geracao Paranapanema S.A., SP (Brazil). Duke Energy International. Market Analysis Dept.; Garcia, Paulo A.N. [Federal University of Juiz de Fora (UFJF), MG (Brazil). Dept. of Circuits

    2009-07-01

    This paper aims to discuss protection issues related to the presence of distributed generation (DG) in distribution systems. A case study is developed to show some impacts of transitions and operations with relay static settings to verify the reliability of systems in the presence of DG. (author)

  20. Optical bus of centralized relay protection and automation system of ...

    African Journals Online (AJOL)

    The article deals with the system of information collection and transfer from a centralized relay protection and automation system for medium voltage electrical units based on a passive optical bus. The issues of electromagnetic compatibility of technical devices are also considered, and the intensity of electromagnetic ...

  1. Personal health record systems and their security protection.

    Science.gov (United States)

    Win, Khin Than; Susilo, Willy; Mu, Yi

    2006-08-01

    The objective of this study is to analyze the security protection of personal health record systems. To achieve this we have investigated different personal health record systems, their security functions, and security issues. We have noted that current security mechanisms are not adequate and we have proposed some security mechanisms to tackle these problems.

  2. A Westinghouse designed distributed mircroprocessor based protection and control system

    International Nuclear Information System (INIS)

    Bruno, J.; Reid, J.B.

    1980-01-01

    For approximately five years, Westinghouse has been involved in the design and licensing of a distributed microprocessor based system for the protection and control of a pressurized water reactor nuclear steam supply system. A 'top-down' design methodology was used, in which the system global performance objectives were specified, followed by increasingly more detailed design specifications which ultimately decomposed the system into its basic hardware and software elements. The design process and design decisions were influenced by the recognition that the final product would have to be verified to ensure its capability to perform the safety-related functions of a class 1E protection system. The verification process mirrored the design process except that it was 'bottom-up' and thus started with the basic elements and worked upwards through the system in increasingly complex blocks. A number of areas which are of interest in a distributed system are disucssed, with emphasis on two systems. The first, the Integrated Protection System is primarily responsible for processing signals from field mounted sensors to provide for reactor trips and the initiation of the Engineered Safety Features. The Integrated Control System, which is organized in a parallel manner, processes other sensor signals and generates the necessary analog and on-off signals to maintain the plant parameters within specified limits. Points covered include system structure, systems partitioning strategies, communications techniques, software design concepts, reliability and maintainability, commercial component availability, interference susceptibility, licensing issues, and applicability. (LL)

  3. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  4. Problems in creating enviroment and health protection systems

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Reznichenko, V.Yu.

    1981-01-01

    The problems in creating environmental and health protection systems are considered with relation to development of nuclear energetics facilities. A problem of transition from the system of detection and observation to the uniform system of environment and health protection and control is set. The objectives and problems of such a system are analyzed and the basic principles of their construction are outlined. A system conception for a fuel energetic complex is described. Usefulness of such systems in solving problems of sites of industrial objects including nuclear power industrial objects, of removal of these objects from service and etc. is shown. New requirements to medical-biological investigations on designing of such a system are discussed [ru

  5. Flexible Thermal Protection System Development for Hypersonic Inflatable Aerodynamic Decelerators

    Science.gov (United States)

    DelCorso, Joseph A.; Bruce, Walter E., III; Hughes, Stephen J.; Dec, John A.; Rezin, Marc D.; Meador, Mary Ann B.; Guo, Haiquan; Fletcher, Douglas G.; Calomino, Anthony M.; Cheatwood, McNeil

    2012-01-01

    The Hypersonic Inflatable Aerodynamic Decelerators (HIAD) project has invested in development of multiple thermal protection system (TPS) candidates to be used in inflatable, high downmass, technology flight projects. Flexible TPS is one element of the HIAD project which is tasked with the research and development of the technology ranging from direct ground tests, modelling and simulation, characterization of TPS systems, manufacturing and handling, and standards and policy definition. The intent of flexible TPS is to enable large deployable aeroshell technologies, which increase the drag performance while significantly reducing the ballistic coefficient of high-mass entry vehicles. A HIAD requires a flexible TPS capable of surviving aerothermal loads, and durable enough to survive the rigors of construction, handling, high density packing, long duration exposure to extrinsic, in-situ environments, and deployment. This paper provides a comprehensive overview of key work being performed within the Flexible TPS element of the HIAD project. Included in this paper is an overview of, and results from, each Flexible TPS research and development activity, which includes ground testing, physics-based thermal modelling, age testing, margins policy, catalysis, materials characterization, and recent developments with new TPS materials.

  6. Computer aided radiation protection system at Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Ishida, J.; Saruta, J.; Yonezawa, R.

    1996-01-01

    Radiation control for workers and workforce has been carried out strictly and effectively taking into account ALARA principle at Tokai Reprocessing Plant (TRP) which has treated about 860 tons of irradiated fuels by now since 1977. The outline of radiation control method at TRP has already been described. This paper briefly describes our experiences and the capabilities of Radiological Information Management System (RIMS) for the safety operation of TRP, followed by radiation exposure control and activity discharge control as examples. By operating the RIMS, the conditions of workplace such as dose equivalent rate and air-contamination are easily and rapidly grasped to take prompt countermeasures for radiological protection, localization and elimination of contamination, and also the past experience data are properly applied to new radiological works to reduce exposures associated with routine and special repetitive maintenance operations at TRP. Finally, authors would like to emphasize that the form and system for radiological control of reprocessing plant has been established throughout our 15-year-experience at TRP. (author)

  7. Electronic Systems for the Protection of Superconducting Devices in the LHC

    CERN Document Server

    Denz, R; Mess, K H

    2008-01-01

    The Large Hadron Collider LHC [1] incorporates an unprecedented amount of superconducting components: magnets, bus-bars, and current leads. Most of them require active protection in case of a transition from the superconducting to the resistive state, the so-called quench. The electronic systems ensuring the reliable quench detection and further protection of these devices have been developed and produced over the last years and are currently being put into operation

  8. Arrangement of the Krsko NPP protection scheme for the power system malfunction cases

    International Nuclear Information System (INIS)

    Omahen, P.; Pavsek, J.; Dirnbek, V.

    1996-01-01

    The Krsko NPP has been designed with the capability to reject 100% of its rated power and runback to the station electrical load. However, an adequate detection system of the outside network degradation is needed for the activation of the existing load drop anticipated (LDA) function. The Krsko NPP electrical, turbine and generator protection systems were carefully evaluated in order to redesign some of its functions. These additional functions should be able to protect and disconnect the plant from the system whenever some serious trouble of the outside electric power system is detected. On the other side, preventive measures should be introduced to avoid unnecessary plant disconnection or unnecessary power system collapse due to such disconnection. At the end, the paper presents a precise design of additional function possibilities for the Krsko NPP electrical protection system. A critical evaluation of these functions is given and the best option is proposed. (author)

  9. Status of physical protection systems of nuclear facilities; survey report

    International Nuclear Information System (INIS)

    Hwang, In Koo; Kwack, Eun Ho; Ahn, Jin Soo; Lee, Hyun Chul; Kim, Jung Soo

    2002-02-01

    This report presents a survey on the physical protection equipment for a nuclear power plant. This survey was conducted by Korea Atomic Energy Research Institute as a part of the project, 'Development of Technologies for National Control of and Accountancy for Nuclear Material,' funded by the Ministry of Science and Technology of Korea. A physical protection system of a nuclear plant includes outer and inner fences, intrusion detection sensors, alarm generation system, illumination equipment, central monitoring and control station, entry control and management system, etc. The outermost fence indicates the boundary of the plant area and prevents a simple or unintentional intrusion. The inner fence area of each plant unit associated with intrusion detection sensors, illuminators, monitoring cameras, serves the key role for physical protection function for the nuclear plant

  10. Strengthening Child Protection Systems for Unaccompanied Migrant Children in Mozambique

    DEFF Research Database (Denmark)

    Verdasco Martinez, Andrea

    children. By identifying children’s reasons for migrating, it identifies the main risks they encounter once they start living and working in Ressano Garcia. These include: lack of access to educational opportunities, exposure to child labour exploitation, trafficking and smuggling. This paper argues......This research sets out to understand the why, how and with whom of rural-urban internal migration of children to Ressano Garcia, a border town between Mozambique and South Africa. It addresses the overarching research question of how to strengthen child protection systems for unaccompanied migrant...... that child protection systems must respond to the unique situation of migrant children’s needs. Child protection and migration policies need to strike a balance between discouraging unsafe migration, which has the potential to expose children to violence, and ensuring that systems are in place for safe...

  11. New digital control and power protection system of VR 1 training reactor

    International Nuclear Information System (INIS)

    Kropik, M.; Matejka, K.; Juoeickova, M.

    2005-01-01

    The contribution describes the new VR-1 training reactor control and power protection system at the Czech Technical University in Prague. The control system provides safety and control functions, calculates average values of the important variables and sends data and system status to the human-machine interface. The upgraded control system is based on a high quality industrial PC. The operating system of the PC is the Microsoft Windows XP with the real time support RTX of the VentureCom Company. The software was developed according to requirements in MS Visual C. The independent power protection system is a component of the reactor safety (protection) system with high quality and reliability requirements. The digital system is redundant; each channel evaluates the reactor power and the velocity of power changes and provides safety functions. The digital part of the channel is multiprocessor-based. The software was developed with respect to nuclear standards. The software design was coded in the C language regarding the NRC restrictions. Configuration management, verification and validation accompanied the software development. Both systems were thoroughly tested. Firstly, the non active tests were carried out. During these tests, the active core of the reactor was subcritical; the input signals were generated from HPIB and VXI controlled instruments to simulate different operational and safety events. The software for instruments control and tests evaluation utilized Agilent VEE development system. After the successful non active checking, the active tests followed. (author)

  12. Endolysosomal pathway activity protects cells from neurotoxic TDP-43

    Directory of Open Access Journals (Sweden)

    Christine Leibiger

    2018-03-01

    Full Text Available The accumulation of protein aggregates in neurons is a typical pathological hallmark of the motor neuron disease amyotrophic lateral sclerosis (ALS and of frontotemporal dementia (FTD. In many cases, these aggregates are composed of the 43 kDa TAR DNA-binding protein (TDP‑43. Using a yeast model for TDP‑43 proteinopathies, we observed that the vacuole (the yeast equivalent of lysosomes markedly contributed to the degradation of TDP‑43. This clearance occurred via TDP‑43-containing vesicles fusing with the vacuole through the concerted action of the endosomal-vacuolar (or endolysosomal pathway and autophagy. In line with its dominant role in the clearance of TDP‑43, endosomal-vacuolar pathway activity protected cells from the detrimental effects of TDP‑43. In contrast, enhanced autophagy contributed to TDP‑43 cytotoxicity, despite being involved in TDP‑43 degradation. TDP‑43’s interference with endosomal-vacuolar pathway activity may have two deleterious consequences. First, it interferes with its own degradation via this pathway, resulting in TDP‑43 accumulation. Second, it affects vacuolar proteolytic activity, which requires endosomal-vacuolar trafficking. We speculate that the latter contributes to aberrant autophagy. In sum, we propose that ameliorating endolysosomal pathway activity enhances cell survival in TDP‑43-associated diseases.

  13. Antibacterial Activity of Hawaiian Corals: Possible Protection from Disease?

    Science.gov (United States)

    Gochfeld, D. J.; Aeby, G. S.; Miller, J. D.

    2006-12-01

    Reports of coral diseases in the Caribbean have appeared with increasing frequency over the past two decades; however, records of coral diseases in the Pacific have lagged far behind. Recent surveys of coral disease in the Hawaiian Islands indicate relatively low, but consistent, levels of disease throughout the inhabited Main and uninhabited Northwestern Hawaiian Islands, and demonstrate variation in levels of disease among the major genera of Hawaiian corals. Although little is known about immune defense to disease in corals, one potential mechanism of defense is the production of antimicrobial compounds that protect corals from pathogens. A preliminary survey of antibacterial chemical defenses among three dominant species of Hawaiian corals was undertaken. Crude aqueous extracts of Porites lobata, Pocillopora meandrina and Montipora capitata were tested against nine strains of bacteria in a growth inhibition assay. Inhibitory extracts were further tested to determine whether their effects were cytostatic or cytotoxic. The bacteria selected included known coral pathogens, potential marine pathogens found in human waste and strains previously identified from the surfaces of Hawaiian corals. Extracts from all three species of coral exhibited a high degree of antibacterial activity, but also a high degree of selectivity against different bacterial strains. In addition, some extracts were stimulatory to some bacteria. In addition to interspecific variability, extracts also exhibited intraspecific variability, both within and between sites. Hawaiian corals have significant antibacterial activity, which may explain the relatively low prevalence of disease in these corals; however, further characterization of pathogens specifically responsible for disease in Hawaiian corals is necessary before we can conclude that antibacterial activity protects Hawaiian corals from disease.

  14. Design, construction and commissioning of SGPR, the fast protection system of RFX

    International Nuclear Information System (INIS)

    Collarin, P.; Trevisan, F.; Guarnieri, M.

    1994-01-01

    RFX, the largest machine for magnetic confinement of plasmas in the RFP line, is provided with a system named SGPR specifically designed for the machine global protection against fast faults which can develop in the plasma, in the windings, in the power supply circuits and in the control system. SGPR is a cabled logic HLL machine, able to organise in few tens of microseconds coordinated machine protection, dealing with more than forty fault signals and activating almost thirty protection commands. SGPR design, manufacture and test program conform the quality control criteria necessary to assure the required high reliability. After a careful and cumbersome commissioning work the system has assumed its protection role. Up to now it has been called to a number of interventions which, even if never due to major faults, have shown its capability of proper operation

  15. Design, construction and commissioning of SGPR, the fast protection system of RFX

    Energy Technology Data Exchange (ETDEWEB)

    Collarin, P.; Trevisan, F. [Instituto Gas Ionizzati del CNR, Padova (Italy); Guarnieri, M. [Universita di Padova (Italy)

    1994-11-01

    RFX, the largest machine for magnetic confinement of plasmas in the RFP line, is provided with a system named SGPR specifically designed for the machine global protection against fast faults which can develop in the plasma, in the windings, in the power supply circuits and in the control system. SGPR is a cabled logic HLL machine, able to organise in few tens of microseconds coordinated machine protection, dealing with more than forty fault signals and activating almost thirty protection commands. SGPR design, manufacture and test program conform the quality control criteria necessary to assure the required high reliability. After a careful and cumbersome commissioning work the system has assumed its protection role. Up to now it has been called to a number of interventions which, even if never due to major faults, have shown its capability of proper operation.

  16. Reactor core protection system using a 4-channel microcomputer

    International Nuclear Information System (INIS)

    Mertens, U.

    1982-12-01

    A four channel microcomputer system was fitted in Grafenrheinfeld NPP for local core protection. This system performs continuous on-line monitoring of peak power density, departure from nucleate boiling ratio and fuel duty. The system implements limitation functions with more sophisticated criteria and improved accuracy. The Grafenrheinfeld system points the way to the employment of computer based limitation system, particularly in the field of programming language, demarkation of tasks, commissioning and documentation aids, streamlining of qualification and structuring of the system. (orig.) [de

  17. Localization of equipment for digital plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed.

  18. Localization of equipment for digital plant protection system

    International Nuclear Information System (INIS)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed

  19. Planning a radar system for protection from the airborne threat

    International Nuclear Information System (INIS)

    Greneker, E.F.; McGee, M.C.

    1986-01-01

    A planning methodology for developing a radar system to protect nuclear materials facilities from the airborne threat is presented. Planning for physical security to counter the airborne threat is becoming even more important because hostile acts by terrorists are increasing and airborne platforms that can be used to bypass physical barriers are readily available. The comprehensive system planning process includes threat and facility surveys, defense hardening, analysis of detection and early warning requirements, optimization of sensor mix and placement, and system implementation considerations

  20. Random Vibration of Space Shuttle Weather Protection Systems

    Directory of Open Access Journals (Sweden)

    Isaac Elishakoff

    1995-01-01

    Full Text Available The article deals with random vibrations of the space shuttle weather protection systems. The excitation model represents a fit to the measured experimental data. The cross-spectral density is given as a convex combination of three exponential functions. It is shown that for the type of loading considered, the Bernoulli-Euler theory cannot be used as a simplified approach, and the structure will be more properly modeled as a Timoshenko beam. Use of the simple Bernoulli-Euler theory may result in an error of about 50% in determining the mean-square value of the bending moment in the weather protection system.

  1. Limerick BWR turbine control and protection system upgrade success

    International Nuclear Information System (INIS)

    Tang, C.K.; Pietryka, T.S.; Federico, P.A.; Williams, J.C.

    2015-01-01

    Westinghouse and Exelon have successfully implemented a digital electro-hydraulic control (DEHC) at Limerick BWR Unit 1 Station to perform the turbine control, protection and reactor pressure functions. The DEHC replaces analog controls and addressed system performance, obsolescence and reliability. This was a first-of-a-kind application for control and protection of the main turbine and BWR pressure control for the distributed control system utilized. The demolition of analog equipment, main control room and front standard modifications, and acceptance testing were completed on schedule during the normal 2014 outage. Key aspects of the project that facilitated this success will be discussed and presented. (author)

  2. Limerick BWR turbine control and protection system upgrade success

    Energy Technology Data Exchange (ETDEWEB)

    Tang, C.K.; Pietryka, T.S.; Federico, P.A., E-mail: tangck@westinghouse.com, E-mail: pietryt@westinghouse, E-mail: federipa@westinghouse.com [Westinghouse Electric Company, LLC, Cranberry Township, PA (United States); Williams, J.C., E-mail: Jonathan.Williams@exeloncorp.com [Exelon Nuclear, Warrenville, IL (United States)

    2015-07-01

    Westinghouse and Exelon have successfully implemented a digital electro-hydraulic control (DEHC) at Limerick BWR Unit 1 Station to perform the turbine control, protection and reactor pressure functions. The DEHC replaces analog controls and addressed system performance, obsolescence and reliability. This was a first-of-a-kind application for control and protection of the main turbine and BWR pressure control for the distributed control system utilized. The demolition of analog equipment, main control room and front standard modifications, and acceptance testing were completed on schedule during the normal 2014 outage. Key aspects of the project that facilitated this success will be discussed and presented. (author)

  3. Erosion Corrosion and Protection of Recycle System with Seawater

    Directory of Open Access Journals (Sweden)

    Xue Jin

    2016-01-01

    Full Text Available In order to investigate the corrosion of recycle system with seawater in rights of power plant, the erosion behavior and mechanism of erosion corrosion in this system constructed with several corrosionresistance alloys have been studied and tested in the condition of high speed fluid with a sand particles. Both special protection technologies and results, one designed by high temperature epoxy resin powder coating and another of the associating method of anode protection together with such same coating, have been discussed as well in this case.

  4. 76 FR 3015 - Prohibitions in Areas Designated by Order; Closure of National Forest System Lands To Protect...

    Science.gov (United States)

    2011-01-19

    ... DEPARTMENT OF AGRICULTURE Forest Service 36 CFR Part 261 RIN 0596-AC93 Prohibitions in Areas Designated by Order; Closure of National Forest System Lands To Protect Privacy of Tribal Activities AGENCY... regarding special closures to provide for closure of National Forest System lands to protect the privacy of...

  5. Information systems in radiation protection: the INIS database

    International Nuclear Information System (INIS)

    Alberdi Larranaga, I.; Marco Arboli, M.

    2011-01-01

    INIS provides a comprehensive service references on literature information on radiation protection (RP), nuclear science and technology, medicine, etc.., Processing most of the world's scientific and technical literature in the area to meet the information needs international community in the areas of interest of the IAEA and the activities related to peaceful use of nuclear science and technology.

  6. The role of privacy protection in healthcare information systems adoption.

    Science.gov (United States)

    Hsu, Chien-Lung; Lee, Ming-Ren; Su, Chien-Hui

    2013-10-01

    Privacy protection is an important issue and challenge in healthcare information systems (HISs). Recently, some privacy-enhanced HISs are proposed. Users' privacy perception, intention, and attitude might affect the adoption of such systems. This paper aims to propose a privacy-enhanced HIS framework and investigate the role of privacy protection in HISs adoption. In the proposed framework, privacy protection, access control, and secure transmission modules are designed to enhance the privacy protection of a HIS. An experimental privacy-enhanced HIS is also implemented. Furthermore, we proposed a research model extending the unified theory of acceptance and use of technology by considering perceived security and information security literacy and then investigate user adoption of a privacy-enhanced HIS. The experimental results and analyses showed that user adoption of a privacy-enhanced HIS is directly affected by social influence, performance expectancy, facilitating conditions, and perceived security. Perceived security has a mediating effect between information security literacy and user adoption. This study proposes several implications for research and practice to improve designing, development, and promotion of a good healthcare information system with privacy protection.

  7. Sulforaphane Protects against Cardiovascular Disease via Nrf2 Activation

    Directory of Open Access Journals (Sweden)

    Yang Bai

    2015-01-01

    Full Text Available Cardiovascular disease (CVD causes an unparalleled proportion of the global burden of disease and will remain the main cause of mortality for the near future. Oxidative stress plays a major role in the pathophysiology of cardiac disorders. Several studies have highlighted the cardinal role played by the overproduction of reactive oxygen or nitrogen species in the pathogenesis of ischemic myocardial damage and consequent cardiac dysfunction. Isothiocyanates (ITC are sulfur-containing compounds that are broadly distributed among cruciferous vegetables. Sulforaphane (SFN is an ITC shown to possess anticancer activities by both in vivo and epidemiological studies. Recent data have indicated that the beneficial effects of SFN in CVD are due to its antioxidant and anti-inflammatory properties. SFN activates NF-E2-related factor 2 (Nrf2, a basic leucine zipper transcription factor that serves as a defense mechanism against oxidative stress and electrophilic toxicants by inducing more than a hundred cytoprotective proteins, including antioxidants and phase II detoxifying enzymes. This review will summarize the evidence from clinical studies and animal experiments relating to the potential mechanisms by which SFN modulates Nrf2 activation and protects against CVD.

  8. Information system of taxones and biotopes of the State protection of nature of the Slovak Republic

    International Nuclear Information System (INIS)

    Jurecek, R.; Kuerthy, A.

    2005-01-01

    Information system of taxones and biotopes (ISTB) of the State protection of environment of the Slovak Republic (SOP SR) is a database system established in order to collection and processing of botanic, zoologic and biotopic data. It has arisen on the base of tasks of the SOP SR resulting from activities of species protection of animals and plants and their monitoring. It is an open system dedicated for exchange of data and for cooperation of specialist of the SOP SR, academic institutes, professional organisations and anon-professional naturalists

  9. IEC 61850 based refurbishment strategies for protection and automation systems

    Energy Technology Data Exchange (ETDEWEB)

    Tholomier, D. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada); Hossenlopp, L. [Areva T and D Automation Inc., Paris (France); Apostolov, A. [Omicron Electronics, Houston, TX (United States)

    2008-07-01

    Electric utilities are currently facing the challenge of refurbishing aging transmission networks and power system infrastructure at a time of severe economic, environmental and competitive constraints. This paper addressed the issue of an appropriate approach to retrofit the hardware and software of substation secondary systems, and how IEC standards could be used to set up a long term strategy. The first part of the paper considered an asset management strategy for refurbishing substation secondary systems, while the second part of the paper addressed the strategies for refurbishing existing power plants. The final section of the paper analyzed refurbishment strategies designed to protect power distribution systems. The impact of IEC 61850 and how legacy devices can be integrated in substation automation systems were discussed. It was concluded that new SCADA systems are needed to handle new technology. Additional features like remote control, remote settings, remote disturbance records analysis and remote maintenance are also needed to properly operate the power system. The value of preventive maintenance using remote monitoring systems to determine the status of all the digital electronic devices installed in substation was also discussed. IEC 61850 offers several opportunities to improve grid operation and control. It supports interoperability between protective relays and control devices from different manufacturers in the substation, which is required in order to achieve substation level interlocking, protection and control functions and improve the efficiency of microprocessor based relays applications. This technology has now passed the initial stage of implementation and several projects are underway worldwide. 13 figs.

  10. Joint force protection advanced security system (JFPASS) "the future of force protection: integrate and automate"

    Science.gov (United States)

    Lama, Carlos E.; Fagan, Joe E.

    2009-09-01

    The United States Department of Defense (DoD) defines 'force protection' as "preventive measures taken to mitigate hostile actions against DoD personnel (to include family members), resources, facilities, and critical information." Advanced technologies enable significant improvements in automating and distributing situation awareness, optimizing operator time, and improving sustainability, which enhance protection and lower costs. The JFPASS Joint Capability Technology Demonstration (JCTD) demonstrates a force protection environment that combines physical security and Chemical, Biological, Radiological, Nuclear, and Explosive (CBRNE) defense through the application of integrated command and control and data fusion. The JFPASS JCTD provides a layered approach to force protection by integrating traditional sensors used in physical security, such as video cameras, battlefield surveillance radars, unmanned and unattended ground sensors. The optimization of human participation and automation of processes is achieved by employment of unmanned ground vehicles, along with remotely operated lethal and less-than-lethal weapon systems. These capabilities are integrated via a tailorable, user-defined common operational picture display through a data fusion engine operating in the background. The combined systems automate the screening of alarms, manage the information displays, and provide assessment and response measures. The data fusion engine links disparate sensors and systems, and applies tailored logic to focus the assessment of events. It enables timely responses by providing the user with automated and semi-automated decision support tools. The JFPASS JCTD uses standard communication/data exchange protocols, which allow the system to incorporate future sensor technologies or communication networks, while maintaining the ability to communicate with legacy or existing systems.

  11. Performance/design criteria review advanced worker protection systems. Topical report

    International Nuclear Information System (INIS)

    1996-08-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D ampersand D) obligations at its numerous sites. Several technologies are being investigated which can potentially reduce D ampersand D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D ampersand D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This document describes an Advanced Worker Protection System (AWPS). The AWPS is built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with a variety of articles of protective clothing and support equipment

  12. Performance/design criteria review advanced worker protection systems. Topical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection to DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This document describes an Advanced Worker Protection System (AWPS). The AWPS is built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with a variety of articles of protective clothing and support equipment.

  13. Software V ampersand V methods for digital plant protection system

    International Nuclear Information System (INIS)

    Kim, Hung-Jun; Han, Jai-Bok; Chun, Chong-Son; Kim, Sung; Kim, Kern-Joong.

    1997-01-01

    Careful thought must be given to software design in the development of digital based systems that play a critical role in the successful operation of nuclear power plants. To evaluate the software verification and validation methods as well as to verify its system performance capabilities for the upgrade instrumentation and control system in the Korean future nuclear power plants, the prototype Digital Plant, Protection System (DPPS) based on the Programmable Logic Controller (PLC) has been constructed. The system design description and features are briefly presented, and the software design and software verification and validation methods are focused. 6 refs., 2 figs

  14. Respiratory protective device design using control system techniques

    Science.gov (United States)

    Burgess, W. A.; Yankovich, D.

    1972-01-01

    The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

  15. New technology for reactor protection system of CAREM reactor

    International Nuclear Information System (INIS)

    Dezzutti, J.C.; Verrastro, C.; Estryk, D.

    2009-01-01

    The use of FPGA in safety functions in a nuclear power plant, increase the reliability of software based systems, without loose any of the function required by the supervision and control systems. In this work the architecture of a Reactor Protection System is described, it use four independent measurement channels in 2 oo 4 configuration, each channel is based on diverse approach in 1 oo 2 configuration, the reliability of this system is near the same than the hardwired logic, with full performance like software based system. (author)

  16. Protective

    Directory of Open Access Journals (Sweden)

    Wessam M. Abdel-Wahab

    2013-10-01

    Full Text Available Many active ingredients extracted from herbal and medicinal plants are extensively studied for their beneficial effects. Antioxidant activity and free radical scavenging properties of thymoquinone (TQ have been reported. The present study evaluated the possible protective effects of TQ against the toxicity and oxidative stress of sodium fluoride (NaF in the liver of rats. Rats were divided into four groups, the first group served as the control group and was administered distilled water whereas the NaF group received NaF orally at a dose of 10 mg/kg for 4 weeks, TQ group was administered TQ orally at a dose of 10 mg/kg for 5 weeks, and the NaF-TQ group was first given TQ for 1 week and was secondly administered 10 mg/kg/day NaF in association with 10 mg/kg TQ for 4 weeks. Rats intoxicated with NaF showed a significant increase in lipid peroxidation whereas the level of reduced glutathione (GSH and the activity of superoxide dismutase (SOD, catalase (CAT, glutathione S-transferase (GST and glutathione peroxidase (GPx were reduced in hepatic tissues. The proper functioning of the liver was also disrupted as indicated by alterations in the measured liver function indices and biochemical parameters. TQ supplementation counteracted the NaF-induced hepatotoxicity probably due to its strong antioxidant activity. In conclusion, the results obtained clearly indicated the role of oxidative stress in the induction of NaF toxicity and suggested hepatoprotective effects of TQ against the toxicity of fluoride compounds.

  17. Programming microphysiological systems for children's health protection (SEBM meeting)

    Science.gov (United States)

    Presentation: Programming microphysiological systems for children’s health protectionAuthors: Knudsen1 T, Klieforth2 B, and Slikker3 W Jr.1National Center for Computational Toxicology/EPA, Research Triangle Park NC2National Center for Environmental Research/EPA, Washington DC3Nat...

  18. Improving 200 MW NDHR reactor protection system with GAL devices

    International Nuclear Information System (INIS)

    Shi Mingde; Li Duo; Xie Zhengguo

    1999-01-01

    The emergence of General Array Logic (GAL), a fairly new type of logic devices with the characteristics of user-definable logic functions, have led to a revolutionary change in the design of logical circuits. The improvements of the reactor protection system for the 200 MW nuclear district heating reactor (NDHR) using GAL are covered

  19. The core protection computer system fitted in Grafenrheinfeld NPP

    International Nuclear Information System (INIS)

    Rietzsch, L.

    1986-01-01

    This paper gives an overview of a four-train core protection computer system for KWU pressurized water reactors. Attention is focused on the methods used to ensure correct computer operation and correct results. Experience gained in trial operation is dealt with. Results of safety analysis of the hardware and the software verification work performed are discussed. (author)

  20. Damage Detection/Locating System Providing Thermal Protection

    Science.gov (United States)

    Woodard, Stanley E. (Inventor); Jones, Thomas W. (Inventor); Taylor, Bryant D. (Inventor); Qamar, A. Shams (Inventor)

    2010-01-01

    A damage locating system also provides thermal protection. An array of sensors substantially tiles an area of interest. Each sensor is a reflective-surface conductor having operatively coupled inductance and capacitance. A magnetic field response recorder is provided to interrogate each sensor before and after a damage condition. Changes in response are indicative of damage and a corresponding location thereof.

  1. A Systemic Approach to Implementing a Protective Factors Framework

    Science.gov (United States)

    Parsons, Beverly; Jessup, Patricia; Moore, Marah

    2014-01-01

    The leadership team of the national Quality Improvement Center on early Childhood ventured into the frontiers of deep change in social systems by funding four research projects. The purpose of the research projects was to learn about implementing a protective factors approach with the goal of reducing the likelihood of child abuse and neglect. In…

  2. Technological measures of protection in the copyright system

    Directory of Open Access Journals (Sweden)

    Radovanović Sanja

    2011-01-01

    Full Text Available Digital exploitation of works often exceed the limit to which the holder can control the exploitation of their intellectual creations, and the protection provided by legal norms are, in the era of a fast exchange of information, may prove to be insufficiently effective. For these reasons, the rights holders are increasingly opting for preventive care through placement of physical obstacles to the exploitation of copyright works, generic called technological protection measures (known as digital right management (DRM. Simultaneously with the development of the application of these measures flows the process of finding ways to circumvent them. Therefore, the effectiveness of technological measures depends on exactly the question of their legal protection, which now exists in most of modern legal systems. However, in the normative solutions there are differences, which reflect the problems in finding adequate forms of protection. They mostly stem from the fact that the sanctioning of circumvention (or preparatory actions of technological measures put into the question the purpose of copyright protection in general. Hence, in this paper we tried to point out the normative solutions accepted in modern legal systems and practical implications of what they have. Conclusion that arises is that the legal shaping of technological measures is not completed and that further technological developments open new dilemmas.

  3. Sandia's experience in designing and implementing integrated high security physical protection systems

    International Nuclear Information System (INIS)

    Caskey, D.L.

    1986-01-01

    As DOE's lead laboratory for physical security, Sandia National Laboratories has had a major physical security program for over ten years. Activities have ranged from component development and evaluation, to full scale system design and implementation. This paper presents some of the lessons learned in designing and implementing state-of-the-art high security physical protection systems for a number of government facilities. A generic system design is discussed for illustration purposes. Sandia efforts to transfer technology to industry are described

  4. Distribution and protective function of pituitary adenylate cyclase-activating polypeptide (PACAP in the retina

    Directory of Open Access Journals (Sweden)

    Tomoya eNakamachi

    2012-11-01

    Full Text Available Pituitary adenylate cyclase-activating polypeptide (PACAP, which is found in 27- or 38-amino acid forms, belongs to the VIP/glucagon/secretin family. PACAP and its three receptor subtypes are expressed in neural tissues, with PACAP known to exert a protective effect against several types of neural damage. The retina is considered to be part of the central nervous system, and retinopathy is a common cause of profound and intractable loss of vision. This review will examine the expression and morphological distribution of PACAP and its receptors in the retina, and will summarize the current state of knowledge regarding the protective effect of PACAP against different kinds of retinal damage, such as that identified in association with diabetes, ultraviolet light, hypoxia, optic nerve transection, and toxins. This article will also address PACAP-mediated protective pathways involving retinal glial cells.

  5. System of nuclear power reactor protection using dynamic logic

    International Nuclear Information System (INIS)

    Carvalho, P.V.R. de; Silva, L.C.R.P. da

    1990-01-01

    The aim of this work is the design of a Reactor Protection System (RPS) using dynamic logic as basic circuitry principle. This concept was developed to permit the electronic and eletromagnetic components employment in 'fail-safe' mode applied to automatic shutdown systems. 'Fail-safe' here means that a fail always yields a constant state that leads to a plant shutdown condition. So the normal condition of operation corresponds to an oscillating state response and the fail or abnormal condition to a static one. At present, almost all modern nuclear plant reactor protection systems use dynamic logic, just differing in the kind of technology employed in the construction of the system. In this work we define what technology best fits our necessities, setting out to design a RPS based on this philosophy. (author) [pt

  6. Recent advances in reactor protection and control system technology

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    After a first-generation digital integrated protection system has been installed on all 1300 MWe PWR units in France, a new digital protection system was developed for the 1450 MWe units, using local area networks, fiber optics, Motorola 68000 microprocessors, and a modular design allowing for the design of any system on the basis of around 50 types of standard cards. In 1993, an upgrading program for this equipment was launched in order to reduce costs, in particular software development costs, further improve hardware modularity and facilitate integration and connection to existing equipment. The basic principles of the units are described together with the implementation of computer-aided software engineering (CASE) tools, interfaces with hard-wired equipment, and multiplexed connections. The nuclear instrumentation systems at the Fessenheim and Bugey plants have been renovated with these equipment

  7. A demonstrator for an integrated subway protection system

    Science.gov (United States)

    Detoma, E.; Capetti, P.; Casati, G.; Billington, S.

    2008-04-01

    In 2006 SEPA has carried on the installation and tests of a demonstrator for an integrated subway protection system at a new subway station in the Naples, Italy) metropolitan area. Protection of a subway system is a difficult task given the amount of passengers transported every day. The demonstrator has been limited to non-intrusive detection techniques not to impair the passenger flow into the station. The demonstrator integrates several technologies and products that have been developed by SEPA or are already available on the market (MKS Instruments,...). The main purpose is to provide detection capabilities for attempts to introduce radioactive substances in the subway station, in order to foil possible attempts to place a dirty bomb, and threat detection and identification following release of chemical agents. The system integrates additional sensors such as video surveillance cameras and air flow sensing to complement the basic sensors suite. The need to protect sensitive installations such as subway stations has been highlighted by the series of terroristics actions carried out in recent years in the subway in London. However, given the number of passengers of a metro system, it is impossible to propose security techniques operating in ways similar to the screening of passengers in airports. Passengers screening and threat detection and identification must be quick, non-intrusive and capable of screening a large number of passengers to be applicable to mass transit systems. In 2005 SEPA, a small company operating in the field of trains video-surveillance systems and radiation detectors, started developing an integrated system to provide a comprehensive protection to subway stations, based on ready available or off-the-shelf components in order to quickly develop a reliable system with available technology. We ruled out at the beginning any new development in order to speed up the fielding of the system in less than one year. The system was developed with

  8. 76 FR 10529 - Special Conditions: Gulfstream Model GVI Airplane; Electronic Systems Security Protection From...

    Science.gov (United States)

    2011-02-25

    ... Security Protection From Unauthorized External Access AGENCY: Federal Aviation Administration (FAA), DOT... electronic system security protection for the aircraft control domain and airline information domain from... identified and assessed, and that effective electronic system security protection strategies are implemented...

  9. Advancement adopted for physical protection system at BARC facilities Tarapur

    International Nuclear Information System (INIS)

    Jaroli, Manish; Ameta, Rohit; Patil, V.H.; Dubey, K.

    2015-01-01

    Considering the prevailing security situation and threat perception to the nuclear installations in particular, it has become essential to strengthen security system at BARC Tarapur in an effective manner to avert any attempt of sabotage and to ensure smooth functioning of security and safety of the nuclear installations. International Atomic Energy Agency (IAEA) and Atomic Energy Regulatory Board (AERB) have provided various security guides for the physical protection system (PPS) for nuclear installations and there has been advancement in physical and personnel protection system due to evolution of new technologies. In line with this, latest technologies have been adopted in PPS for BARC facilities, Tarapur recently. This includes state of art RFID card based access control, visitor and contractor management system, electronic key management system. Digital signature based biometric visitor and contractor management system; Digital signature based leave management system; Distress alarm system (DAS); Guard tour monitoring system (GTMS); Secure network access system (SNAS) as well as multilayered access control system at plant level. This will strengthen the surveillance and monitoring of personnel and visitors at BARC facilities. (author)

  10. Dedicated monitoring and machinery protection systems on reciprocating compressors

    Energy Technology Data Exchange (ETDEWEB)

    Grande, Alvaro; Wenisch, Markus [Hoerbiger Ventilwerke GmbH and Co KG, Wien (Austria); Jacobs, Denis [HOERBIGER do Brasil Industria de Equipamentos, Cajamar, SP (Brazil)

    2012-07-01

    Growing demands on reciprocating compressors (recips) in the process gas industry require particular solutions for machinery protection and performance monitoring systems. Compared to rotating equipment, monitoring systems for recips have to consider the special mechanical and physical characteristics, such as oscillating masses, variable vibration behaviour and varying operating conditions. Furthermore, they provide valuable information about the performance of cylinder related components allowing the operator the optimization of efficiency and availability, and therefore increase production. (author)

  11. Impact Testing of Orbiter Thermal Protection System Materials

    Science.gov (United States)

    Kerr, Justin

    2006-01-01

    This viewgraph presentation reviews the impact testing of the materials used in designing the shuttle orbiter thermal protection system (TPS). Pursuant to the Columbia Accident Investigation Board recommendations a testing program of the TPS system was instituted. This involved using various types of impactors in different sizes shot from various sizes and strengths guns to impact the TPS tiles and the Leading Edge Structural Subsystem (LESS). The observed damage is shown, and the resultant lessons learned are reviewed.

  12. Lightning protection scheme for the CPRF/ZTH system complex

    International Nuclear Information System (INIS)

    Konkel, H.

    1987-01-01

    This paper describes some of the background in the design and the lightning protection and grounding scheme recommended for the CPRF/ZTH system at the Los Alamos Laboratory. Standard power industry practices were applied to minimize the effect on both the system and personnel of a high magnitude, direct lightning discharge in the CPRF/ZTH area. The recommended scheme is in compliance with existing local and national electric and safety codes. 7 refs., 3 figs

  13. Sun Protection Preferences and Behaviors among Young Adult Males during Maximum Ultraviolet Radiation Exposure Activities

    Science.gov (United States)

    Wickenheiser, Marilyn; Baker, Mary Kate; Gaber, Rikki; Blatt, Hanz; Robinson, June K.

    2013-01-01

    This study explores sun protection attitudes, preferences, and behaviors among young adult males participating in an open-field activity with extreme ultraviolet radiation exposure. Male drum corps members (n = 137) responded to survey questions regarding their behavior and willingness to engage in sun protection and barriers to sunscreen usage. A subset of members (n = 31) participated in cognitive interviews exploring various sunscreen products and intervention techniques. Participants were knowledgeable about health risks and protection benefits regarding sun exposure. Generally, males had positive attitudes and normative beliefs about using sunscreen. A barrier to sunscreen re-application was lack of adequate time to reapply sunscreen during the open field activity. Males preferred a towelette application method, but were unfamiliar with its efficacy and proper use. Thus, they were more likely to use the more familiar sunscreen spray. To increase sun protection behaviors and lower skin cancer risk for males participating in open-field activities, breaks must be allotted every 2 h and have sufficient time to allow sunscreen application. Future development and research into delivery systems that rapidly and evenly apply sunscreen may help lower exposure in this population. PMID:23912201

  14. Sun Protection Preferences and Behaviors among Young Adult Males during Maximum Ultraviolet Radiation Exposure Activities

    Directory of Open Access Journals (Sweden)

    June K. Robinson

    2013-07-01

    Full Text Available This study explores sun protection attitudes, preferences, and behaviors among young adult males participating in an open-field activity with extreme ultraviolet radiation exposure. Male drum corps members (n = 137 responded to survey questions regarding their behavior and willingness to engage in sun protection and barriers to sunscreen usage. A subset of members (n = 31 participated in cognitive interviews exploring various sunscreen products and intervention techniques. Participants were knowledgeable about health risks and protection benefits regarding sun exposure. Generally, males had positive attitudes and normative beliefs about using sunscreen. A barrier to sunscreen re-application was lack of adequate time to reapply sunscreen during the open field activity. Males preferred a towelette application method, but were unfamiliar with its efficacy and proper use. Thus, they were more likely to use the more familiar sunscreen spray. To increase sun protection behaviors and lower skin cancer risk for males participating in open-field activities, breaks must be allotted every 2 h and have sufficient time to allow sunscreen application. Future development and research into delivery systems that rapidly and evenly apply sunscreen may help lower exposure in this population.

  15. Preliminary Validation and Verification Plan for CAREM Reactor Protection System

    International Nuclear Information System (INIS)

    Fittipaldi, Ana; Maciel Felix

    2000-01-01

    The purpose of this paper, is to present a preliminary validation and verification plan for a particular architecture proposed for the CAREM reactor protection system with software modules (computer based system).These software modules can be either own design systems or systems based in commercial modules such as programmable logic controllers (PLC) redundant of last generation.During this study, it was seen that this plan can also be used as a validation and verification plan of commercial products (COTS, commercial off the shelf) and/or smart transmitters.The software life cycle proposed and its features are presented, and also the advantages of the preliminary validation and verification plan

  16. Vision-based pedestrian protection systems for intelligent vehicles

    CERN Document Server

    Geronimo, David

    2013-01-01

    Pedestrian Protection Systems (PPSs) are on-board systems aimed at detecting and tracking people in the surroundings of a vehicle in order to avoid potentially dangerous situations. These systems, together with other Advanced Driver Assistance Systems (ADAS) such as lane departure warning or adaptive cruise control, are one of the most promising ways to improve traffic safety. By the use of computer vision, cameras working either in the visible or infra-red spectra have been demonstrated as a reliable sensor to perform this task. Nevertheless, the variability of human's appearance, not only in

  17. Optimal channel utilization and service protection in cellular communication systems

    DEFF Research Database (Denmark)

    Iversen, Villy Bæk

    1997-01-01

    In mobile communications an efficient utilization of the channels is of great importance.In this paper we consider the basic principles for obtaining the maximum utilization, and we study strategies for obtaining these limits.In general a high degree of sharing is efficient, but requires service...... protection mechanisms for protecting services and subscriber groups.We study cellular systems with overlaid cells, and the effect of overlapping cells, and we show that by dynamic channel allocation we obtain a high utilization.The models are generalizations of the Erlang-B formula, and can be evaluated...

  18. Container lid gasket protective strip for double door transfer system

    Science.gov (United States)

    Allen, Jr., Burgess M

    2013-02-19

    An apparatus and a process for forming a protective barrier seal along a "ring of concern" of a transfer container used with double door systems is provided. A protective substrate is supplied between a "ring of concern" and a safety cover in which an adhesive layer of the substrate engages the "ring of concern". A compressive foam strip along an opposite side of the substrate engages a safety cover such that a compressive force is maintained between the "ring of concern" and the adhesive layer of the substrate.

  19. Metformin inhibits glutaminase activity and protects against hepatic encephalopathy.

    Directory of Open Access Journals (Sweden)

    Javier Ampuero

    activity in vitro. Therefore, metformin use seems to be protective against hepatic encephalopathy in diabetic cirrhotic patients.

  20. Policy and practice in Myanmar's protected area system.

    Science.gov (United States)

    Myint Aung, U

    2007-07-01

    Myanmar's protected area (PA) system began nearly 150 years ago under royal patronage. Park policies and practices, embodied in 19 pieces of legislation developed sporadically during and after the colonial period. As a result of the FAO-UNDP's Nature Conservation and National Parks Project (1981-1985) the government established the Nature & Wildlife Conservation Division and placed it within the Forest Department as the agency responsible for PA management. As a consequence the number of parks increased from 14 to 33. Myanmar's median park size is less than 50 km(2), but only five parks (15%) are larger than 1000 km(2). Most parks conserve terrestrial habitats; parks encompassing inland wetlands, mangrove, and marine habitats are limited in number and size. Existing PAs unequally represent Myanmar's ecosystems; the Malay Transition, Burmese coast, Burmese Transition and Cardamom Mountains bio-units are under-represented within the system. The effective total PA size (i.e., area of all parks less the area of 13 paper parks) is currently about 2.1%. Budgetary support for parks increased 11% since 1996, but is insufficient to address park needs, particularly in remote parks that are understaffed. Limited education and training of PA staff is a major factor limiting effective park management. Fifty-eight percent of park wardens are educated as foresters, and 42% have university degrees. The average posting in a park is 4 years, which is less than ideal for management continuity. Recommended actions to secure Myanmar's PAs include evaluation and reformulation of policies, increasing representation of Myanmar's habitats within the PA system, management planning, and standardizing protocols for anti-poaching patrols and other forms of law enforcement. Improved leadership training for wardens and range forest officers can also improve park management. Funding for community relations and more integrated management of parks and people can reduce conflicts, while

  1. Overvoltage protection for magnetic system during disruption in tokamak

    International Nuclear Information System (INIS)

    Zhang, Ming; Li, Xiaolong; He, Yang; Zhang, Jun; Chen, Zhongyong; Yu, Kexun

    2015-01-01

    Highlights: • We investigate the way to limit the plasma disruption overvoltage by using the MOVs. • An overvoltage model of plasma disruption is introduced. • The overvoltage protection scheme has been verified by disruption experiments. • The overvoltage during plasma disruption can be limited to 330 V. - Abstract: During a plasma disruption the magnetic flux in the tokamak changes rapidly, which in most cases will cause high-voltage surges among the magnetic systems and may bring severe damage to the components if there is no overvoltage protection. This paper investigates the way to limit the plasma disruption overvoltage and absorb the energy with the use of metal oxide varistors (MOVs). An overvoltage model of plasma disruption is introduced which can be used for the simulation of plasma disruption and the analysis of the overvoltage. The effectiveness of the overvoltage protection system is validated with disruption experiments. It shows that by optimizing the varistors voltage, the overvoltage during plasma disruption can be limited to an ideal low value. Now the overvoltage protection system has been deployed in J-TEXT tokamak and serves well for daily experiments.

  2. Dependable Design Flow for Protection Systems using Programmable Logic Devices

    CERN Document Server

    Kwiatkowski, M

    2011-01-01

    Programmable Logic Devices (PLD) such as Field Programmable Gate Arrays (FPGA) are becoming more prevalent in protection and safety-related electronic systems. When employing such programmable logic devices, extra care and attention needs to be taken. The final synthesis result, used to generate the bit-stream to program the device, must be shown to meet the design’s requirements. This paper describes how to maximize confidence using techniques such as Formal Methods, exhaustive Hardware Description Language (HDL) code simulation and hardware testing. An example is given for one of the critical functions of the Safe Machine Parameters (SMP) system, used in the protection of the Large Hadron Collider (LHC) at CERN. CERN is also working towards an adaptation of the IEC- 61508 lifecycle designed for Machine Protection Systems (MPS), and the High Energy Physics environment, implementation of a protection function in FPGA code is only one small step of this lifecycle. The ultimate aim of this project is to cre...

  3. Marine Protected Dramas: The Flaws of the Brazilian National System of Marine Protected Areas

    Science.gov (United States)

    Gerhardinger, Leopoldo C.; Godoy, Eduardo A. S.; Jones, Peter J. S.; Sales, Gilberto; Ferreira, Beatrice P.

    2011-04-01

    This article discusses the current problems and issues associated with the implementation of a National System of Marine Protected Areas in Brazil. MPA managers and higher governmental level authorities were interviewed about their perceptions of the implementation of a national MPA strategy and the recent changes in the institutional arrangement of government marine conservation agencies. Interviewees' narratives were generally pessimistic and the National System was perceived as weak, with few recognizable marine conservation outcomes on the ground. The following major flaws were identified: poor inter-institutional coordination of coastal and ocean governance; institutional crisis faced by the national government marine conservation agency; poor management within individual MPAs; problems with regional networks of marine protected areas; an overly bureaucratic management and administrative system; financial shortages creating structural problems and a disconnect between MPA policy and its delivery. Furthermore, a lack of professional motivation and a pessimistic atmosphere was encountered during many interviews, a malaise which we believe affects how the entire system is able to respond to crises. Our findings highlight the need for a better understanding of the role of `leadership' in the performance of socio-ecological systems (such as MPA networks), more effective official evaluation mechanisms, more localized audits of (and reforms if necessary to) Brazil's federal biodiversity conservation agency (ICMBio), and the need for political measures to promote state leadership and support. Continuing to focus on the designation of more MPAs whilst not fully addressing these issues will achieve little beyond fulfilling, on paper, Brazil's international marine biodiversity commitments.

  4. Testing methodology of embedded software in digital plant protection system

    International Nuclear Information System (INIS)

    Seong, Ah Young; Choi, Bong Joo; Lee, Na Young; Hwang, Il Soon

    2001-01-01

    It is necessary to assure the reliability of software in order to digitalize RPS(Reactor Protection System). Since RPS causes fatal damage on accidental cases, it is classified as Safety 1E class. Therefore we propose the effective testing methodology to assure the reliability of embedded software in the DPPS(Digital Plant Protection System). To test the embedded software effectively in DPPS, our methodology consists of two steps. The first is the re-engineering step that extracts classes from structural source program, and the second is the level of testing step which is composed of unit testing, Integration Testing and System Testing. On each testing step we test the embedded software with selected test cases after the test item identification step. If we use this testing methodology, we can test the embedded software effectively by reducing the cost and the time

  5. Heat Exchange in “Human body - Thermal protection - Environment” System

    Science.gov (United States)

    Khromova, I. V.

    2017-11-01

    This article is devoted to the issues of simulation and calculation of thermal processes in the system called “Human body - Thermal protection - Environment” under low temperature conditions. It considers internal heat sources and convective heat transfer between calculated elements. Overall this is important for the Heat Transfer Theory. The article introduces complex heat transfer calculation method and local thermophysical parameters calculation method in the system called «Human body - Thermal protection - Environment», considering passive and active thermal protections, thermophysical and geometric properties of calculated elements in a wide range of environmental parameters (water, air). It also includes research on the influence that thermal resistance of modern materials, used in special protective clothes development, has on heat transfer in the system “Human body - Thermal protection - Environment”. Analysis of the obtained results allows adding of the computer research data to experiments and optimizing of individual life-support system elements, which are intended to protect human body from exposure to external factors.

  6. Real-time information and processing system for radiation protection

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.; Stoica, M.; Badea, E.; Guta, V.

    1999-01-01

    The real-time information and processing system has as main task to record, collect, process and transmit the radiation level and weather data, being proposed for radiation protection, environmental monitoring around nuclear facilities and for civil defence. Such a system can offer information in order to provide mapping, data base, modelling and communication and to assess the consequences of nuclear accidents. The system incorporates a number of stationary or mobile radiation monitoring equipment, weather parameter measuring station, a GIS-based information processing center and the communication network, all running on a real-time operating system. It provides the automatic data collection on-line and off-line, remote diagnostic, advanced presentation techniques, including a graphically oriented executive support, which has the ability to respond to an emergency by geographical representation of the hazard zones on the map.The system can be integrated into national or international environmental monitoring systems, being based on local intelligent measuring and transmission units, simultaneous processing and data presentation using a real-time operating system for PC and geographical information system (GIS). Such an integrated system is composed of independent applications operating under the same computer, which is capable to improve the protection of the population and decision makers efforts, updating the remote GIS data base. All information can be managed directly from the map by multilevel data retrieving and presentation by using on-line dynamic evolution of the events, environment information, evacuation optimization, image and voice processing

  7. 78 FR 66384 - Membership of the Merit Systems Protection Board's Performance Review Board

    Science.gov (United States)

    2013-11-05

    ... MERIT SYSTEMS PROTECTION BOARD Membership of the Merit Systems Protection Board's Performance Review Board AGENCY: Merit Systems Protection Board. ACTION: Notice. SUMMARY: Notice is hereby given of the members of the Merit Systems Protection Board's Performance Review Board. DATES: November 5, 2013...

  8. 75 FR 3939 - Merit Systems Protection Board (MSPB) Provides Notice of Opportunity To File Amicus Briefs

    Science.gov (United States)

    2010-01-25

    ... MERIT SYSTEMS PROTECTION BOARD Merit Systems Protection Board (MSPB) Provides Notice of Opportunity To File Amicus Briefs AGENCY: Merit Systems Protection Board. ACTION: Notice. SUMMARY: Pursuant to 5 U.S.C. 7521 and 5 CFR 1201.131, the Merit Systems Protection Board (MSPB) is providing notice of...

  9. 78 FR 49479 - Updates to List of National System of Marine Protected Areas MPAs

    Science.gov (United States)

    2013-08-14

    ... System of Marine Protected Areas MPAs AGENCY: National Marine Protected Areas Center (MPA Center), Office... Marine Protected Areas (MPAs). SUMMARY: The National System of Marine Protected Areas (MPAs) provides a... Protected Areas Center (MPA Center). The managing agencies listed above were then asked to make a final...

  10. 75 FR 67989 - Agency Information Collection Activities: Office of Infrastructure Protection; Infrastructure...

    Science.gov (United States)

    2010-11-04

    ... DEPARTMENT OF HOMELAND SECURITY [Docket No. DHS-2010-0084] Agency Information Collection Activities: Office of Infrastructure Protection; Infrastructure Protection Stakeholder Input Project--Generic... comments; New Information Collection Request: 1670-NEW. SUMMARY: The Department of Homeland Security...

  11. IMPROVING PATENT PROTECTION OF INVENTIVE ACTIVITY IN THE CONTEXT OF EU LEGISLATION

    Directory of Open Access Journals (Sweden)

    Nataliya Philyk

    2017-07-01

    Full Text Available Purpose: clarify legal nature of relations emerging in connection with registration of patent law objects. In this article the authors research special features of legal regulation of inventive activity. In particular, they consider several issues of patenting the patent law objects and clarify legal nature of relations arose during registration of the rights to the patent law objects. Methods: formal legal and case-study methods together with inductive reasoning, and comparison were used to analyse the legislation in the area of jurisdiction inventive activity Results: during the research the authors focus their attention to the drawbacks of the effective legislation and form the main directions of the effective legislation improvement in accordance with international law in the context of the patent law objects protection. Special attention is devoted to analysis of the main threats of the patent law violations and ways to overcome them. Conclusions: the results confirming improving the efficiency of the system of intellectual property protection through institutional changes and changes in the legal regulation of inventive activity and results will have a positive impact on the reform of the system of intellectual property protection in Ukraine.

  12. Studies on the protection effects of functional foods for skin immune system from radiation damage

    International Nuclear Information System (INIS)

    Yee, Sung Tae; Shin, Seong Hae; Kim, Do Sun; Heo, Ji Yun; Kang, Hye In

    2007-07-01

    We evaluated the protective effects of pilot products (HemoHIM and HemoTonic) on the UV-induced skin immune damages as the following. · Protective effects of HemoHIM and HemoTonic against UV using contact hypersensitivity model - Protection against depression of contact hypersensitivity by administration and skin application of HemoHIM and HemoTonic - Induction of dendritic cell differentiation and maturation by HemoHIM and HemoTonic treatment - Improvement of antigen-presenting activity of dedritic cells by HemoHIM and HemoTonic treatment · Protective effects of HemoHIM and HemoTonic on skin immune system against UV-irradiation - Protection of antigen-presenting activity of dendritic cells under UV-irradiation - In vivo protection of antigen-presenting activity of Langerhans cells in UV-irradiated mice · Protective effects of HemoHIM on UV-induced apoptosis of dendritic cells - Inhibition of cell membrane change, mitochondrial potential change, SubG1 cell population, nuclear condensation, and DNA fragmentation in UV-irradiated dendritic cells · Anti-allergic effects of HemoHIM and HemoTonic in human adipocyte HMC-1 cells - Inhibition of allergic histamine release from adipocytes - Inhibition of secretion of inflammatory cytokines (IL-6, IL-8, TNF-α, GM-CSF) - Inhibition of c-kit, tryptase, FcεRI mRNA expression From these results, the developed functional food products (HemoHIM, HemoTonic) showed the protection and recovery of the immune functions in the UV-irradiated skin. It is suggested that these products may be used as a new functional food or cosmetic material for the protection of skin damage and the promotion of recovery

  13. Studies on the protection effects of functional foods for skin immune system from radiation damage

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Sung Tae; Shin, Seong Hae; Kim, Do Sun; Heo, Ji Yun; Kang, Hye In [Sunchon National University, Sunchon (Korea, Republic of)

    2007-07-15

    We evaluated the protective effects of pilot products (HemoHIM and HemoTonic) on the UV-induced skin immune damages as the following. centre dot Protective effects of HemoHIM and HemoTonic against UV using contact hypersensitivity model - Protection against depression of contact hypersensitivity by administration and skin application of HemoHIM and HemoTonic - Induction of dendritic cell differentiation and maturation by HemoHIM and HemoTonic treatment - Improvement of antigen-presenting activity of dedritic cells by HemoHIM and HemoTonic treatment centre dot Protective effects of HemoHIM and HemoTonic on skin immune system against UV-irradiation - Protection of antigen-presenting activity of dendritic cells under UV-irradiation - In vivo protection of antigen-presenting activity of Langerhans cells in UV-irradiated mice centre dot Protective effects of HemoHIM on UV-induced apoptosis of dendritic cells - Inhibition of cell membrane change, mitochondrial potential change, SubG1 cell population, nuclear condensation, and DNA fragmentation in UV-irradiated dendritic cells centre dot Anti-allergic effects of HemoHIM and HemoTonic in human adipocyte HMC-1 cells - Inhibition of allergic histamine release from adipocytes - Inhibition of secretion of inflammatory cytokines (IL-6, IL-8, TNF-alpha, GM-CSF) - Inhibition of c-kit, tryptase, FcepsilonRI mRNA expression From these results, the developed functional food products (HemoHIM, HemoTonic) showed the protection and recovery of the immune functions in the UV-irradiated skin. It is suggested that these products may be used as a new functional food or cosmetic material for the protection of skin damage and the promotion of recovery

  14. Assessing the efficiency of information protection systems in the computer systems and networks

    OpenAIRE

    Nachev, Atanas; Zhelezov, Stanimir

    2015-01-01

    The specific features of the information protection systems in the computer systems and networks require the development of non-trivial methods for their analysis and assessment. Attempts for solutions in this area are given in this paper.

  15. Hybrid Plasma Reactor/Filter for Transportable Collective Protection Systems

    Energy Technology Data Exchange (ETDEWEB)

    Josephson, Gary B.; Tonkyn, Russell G.; Frye, J. G.; Riley, Brian J.; Rappe, Kenneth G.

    2011-04-06

    Pacific Northwest National Laboratory (PNNL) has performed an assessment of a Hybrid Plasma/Filter system as an alternative to conventional methods for collective protection. The key premise of the hybrid system is to couple a nonthermal plasma (NTP) reactor with reactive adsorption to provide a broader envelope of protection than can be provided through a single-solution approach. The first step uses highly reactive species (e.g. oxygen radicals, hydroxyl radicals, etc.) created in a nonthermal plasma (NTP) reactor to destroy the majority (~75% - 90%) of an incoming threat. Following the NTP reactor an O3 reactor/filter uses the O3 created in the NTP reactor to further destroy the remaining organic materials. This report summarizes the laboratory development of the Hybrid Plasma Reactor/Filter to protect against a ‘worst-case’ simulant, methyl bromide (CH3Br), and presents a preliminary engineering assessment of the technology to Joint Expeditionary Collective Protection performance specifications for chemical vapor air purification technologies.

  16. Routine testing on protective and safety systems and components

    International Nuclear Information System (INIS)

    Rysy, W.

    1977-01-01

    1) In-process inspection, tests during commissioning. 2) Tests during reactor operation. 2.1) Reactor protection system, for example: continuous auto-testing by a dynamic system, check of the output signals; 2.2) safety features: selected examples: functional tests on the ECCS, trial operation of the emergency diesels. 3) Tests during refuelling phase. 3.1) Containment: Leakage rate tests, leak testing; 3.2) coolant system: selected examples: inservice inspections of the pressure vessel, eddy current testing of the steam generator, functional tests of safety valves. (orig./HP) [de

  17. On-Line Generation and Arming of System Protection Schemes

    DEFF Research Database (Denmark)

    Pedersen, Andreas Søndergaard; Blanke, Mogens; Møller, Jakob Glarbo

    2016-01-01

    This paper presents a new method to automatically generate system protection schemes in real-time, where contingencies are filtered using a method providing N– 1 system snapshots. With future power systems consisting largely of renewable distributed generation with time-varying production, highly....... The method is based on a recently proposed method of calculating post-contingency Thevenin equivalents, which are used to assess the security of the post-contingency condition. The contingencies that violate the emergency limits are contained by pre-determining event-based remedial actions. The instability...

  18. Pius, self-protective thermohydraulics transient without safety system intervention

    International Nuclear Information System (INIS)

    Fredell, J.; Bredolt, V.

    1989-01-01

    In this paper, the self-protective thermohydraulic feedback of the PIUS reactor system is illustrated by an in-depth discussion of one typical transient. The selected transient is an undetected total loss of feedwater in the complete absence of conventional safety system intervention. The reactor shuts itself down to residual power in two steps. First, the power decreases due to the strongly negative moderator temperature reactivity coefficient, and then a complete shutdown occurs by ingress of cold, highly borated water from the reactor pool. The transient is terminated without any harm to the fuel or paint systems

  19. Reactor protection system with automatic self-testing and diagnostic

    International Nuclear Information System (INIS)

    Gaubatz, D.C.

    1996-01-01

    A reactor protection system is disclosed having four divisions, with quad redundant sensors for each scram parameter providing input to four independent microprocessor-based electronic chassis. Each electronic chassis acquires the scram parameter data from its own sensor, digitizes the information, and then transmits the sensor reading to the other three electronic chassis via optical fibers. To increase system availability and reduce false scrams, the reactor protection system employs two levels of voting on a need for reactor scram. The electronic chassis perform software divisional data processing, vote 2/3 with spare based upon information from all four sensors, and send the divisional scram signals to the hardware logic panel, which performs a 2/4 division vote on whether or not to initiate a reactor scram. Each chassis makes a divisional scram decision based on data from all sensors. Automatic detection and discrimination against failed sensors allows the reactor protection system to automatically enter a known state when sensor failures occur. Cross communication of sensor readings allows comparison of four theoretically ''identical'' values. This permits identification of sensor errors such as drift or malfunction. A diagnostic request for service is issued for errant sensor data. Automated self test and diagnostic monitoring, sensor input through output relay logic, virtually eliminate the need for manual surveillance testing. This provides an ability for each division to cross-check all divisions and to sense failures of the hardware logic. 16 figs

  20. Fail-safe computer-based plant protection systems

    International Nuclear Information System (INIS)

    Keats, A.B.

    1983-01-01

    A fail-safe mode of operation for computers used in nuclear reactor protection systems was first evolved in the UK for application to a sodium cooled fast reactor. The fail-safe properties of both the hardware and the software were achieved by permanently connecting test signals to some of the multiplexed inputs. This results in an unambiguous data pattern, each time the inputs are sequentially scanned by the multiplexer. The ''test inputs'' simulate transient excursions beyond defined safe limits. The alternating response of the trip algorithms to the ''out-of-limits'' test signals and the normal plant measurements is recognised by hardwired pattern recognition logic external to the computer system. For more general application to plant protection systems, a ''Test Signal Generator'' (TSG) is used to compute and generate test signals derived from prevailing operational conditions. The TSG, from its knowledge of the sensitivity of the trip algorithm to each of the input variables, generates a ''test disturbance'' which is superimposed upon each variable in turn, to simulate a transient excursion beyond the safe limits. The ''tripped'' status yielded by the trip algorithm when using data from a ''disturbed'' input forms part of a pattern determined by the order in which the disturbances are applied to the multiplexer inputs. The data pattern formed by the interleaved test disturbances is again recognised by logic external to the protection system's computers. This fail-safe mode of operation of computer-based protection systems provides a powerful defence against common-mode failure. It also reduces the importance of software verification in the licensing procedure. (author)

  1. The effect of acid rain stress on membrane protective system of spinach and the conservation of rare earth elements

    International Nuclear Information System (INIS)

    Chongling, Y; Yetang, H.

    1998-01-01

    Full text: Based on pot experiments, the effect of acid rain stress on membrane protective system of spinach and the effect of rare earth elements has been studied. The results showed, stress of acid rain resulted in decrease of over all level of superoxide dismutase activity, catalase activity and increase of peroxidase (POD) activity. After being treated by rare earth elements, the overall level of superoxide dismutase activity and catalase activity were increased and the peak value of activity variation curve moved toward to the direction of higher acidity. POD activity increased slightly, comparing with the plants that hadn't been treated by rare earth elements under same acid rain condition; the three important enzymes of membrane protective system could be kept on a relatively stable level. It was clear that in relative lower acidity condition, rare earth elements can reduce the impact of acid rain on the membrane protective system

  2. Improving radioactive waste management: an overview of the Environmental Protection Agency's low-activity waste effort.

    Science.gov (United States)

    Schultheisz, Daniel J; Czyscinski, Kenneth S; Klinger, Adam D

    2006-11-01

    Radioactive waste disposal in the United States is marked by a fragmented regulatory system, with requirements that often focus on the origin or statutory definition of the waste, rather than the hazard of the material in question. It may be possible to enhance public protection by moving toward a system that provides disposal options appropriate for the hazard presented by the waste in question. This paper summarizes aspects of an approach focusing on the potential use, with appropriate conditions, of Resource Conservation and Recovery Act Subtitle-C hazardous waste landfills for disposal of "low-activity" wastes and public comments on the suggested approach.

  3. Angle Control-Based Multi-Terminal Out-of-Step Protection System

    OpenAIRE

    Antans Sauhats; Andrejs Utans; Dmitrijs Antonovs; Andrejs Svalovs

    2017-01-01

    From time to time a sequence of unexpected and overlapping contingencies may lead to power system angular instability and even blackouts if not addressed adequately by means of an out-of-step (OOS) protection system. The motivation of the paper is an attempt to develop a workable prototype of the OOS protection system. The deficiencies of the protection currently used in the Latvian Power System network are highlighted and a new protection structure is proposed. The protection system comprise...

  4. Protecting peroxidase activity of multilayer enzyme-polyion films using outer catalase layers.

    Science.gov (United States)

    Lu, Haiyun; Rusling, James F; Hu, Naifei

    2007-12-27

    Films constructed layer-by-layer on electrodes with architecture {protein/hyaluronic acid (HA)}n containing myoglobin (Mb) or horseradish peroxidase (HRP) were protected against protein damage by H2O2 by using outer catalase layers. Peroxidase activity for substrate oxidation requires activation by H2O2, but {protein/HA}n films without outer catalase layers are damaged slowly and irreversibly by H2O2. The rate and extent of damage were decreased dramatically by adding outer catalase layers to decompose H2O2. Comparative studies suggest that protection results from catalase decomposing a fraction of the H2O2 as it enters the film, rather than by an in-film diffusion barrier. The outer catalase layers controlled the rate of H2O2 entry into inner regions of the film, and they biased the system to favor electrocatalytic peroxide reduction over enzyme damage. Catalase-protected {protein/HA}n films had an increased linear concentration range for H2O2 detection. This approach offers an effective way to protect biosensors from damage by H2O2.

  5. Report of the First European workshop on the ethical dimensions of the radiological protection system

    International Nuclear Information System (INIS)

    2013-01-01

    The objective of this first European Workshop was to explore further the ethical values underlying the system of radiological protection but also to shed some light on different aspects of the practical implementation of the system that raise ethical questions and value judgments, such as: scientific uncertainty; rationale of the dose limits; stakeholder engagement; and, sustainable development. The workshop has been organized around lectures in plenary sessions, while the discussion activities have been developed within three working groups involving all the participants discussing two questions: - what issues of radiation protection refer to ethics; and what are the ethical values (explicit and implicit) that underlie the system of radiological protection? The present report presents some of the essential points that emerged from the lectures and from the discussion developed around them. It also presents a summary of the main subjects discussed in the working groups, and the main points addressed during the general discussion

  6. Cost and performance analysis of physical protection systems - a case study

    International Nuclear Information System (INIS)

    Hicks, M.J.; Snell, M.S.; Sandoval, J.S.; Potter, C.S.

    1998-01-01

    Design and analysis of physical protection systems requires (1) identification of mission critical assets; (2) identification of potential threats that might undermine mission capability; (3) identification of the consequences of loss of mission-critical assets (e.g., time and cost to recover required capability and impact on operational readiness); and (4) analysis of the effectiveness of physical protection elements. CPA -- Cost and Performance Analysis -- addresses the fourth of these four issues. CPA is a methodology that joins Activity Based Cost estimation with performance-based analysis of physical protection systems. CPA offers system managers an approach that supports both tactical decision making and strategic planning. Current exploratory applications of the CPA methodology address analysis of alternative conceptual designs. Hypothetical data is used to illustrate this process

  7. A privacy protection for an mHealth messaging system

    Science.gov (United States)

    Aaleswara, Lakshmipathi; Akopian, David; Chronopoulos, Anthony T.

    2015-03-01

    In this paper, we propose a new software system that employs features that help the organization to comply with USA HIPAA regulations. The system uses SMS as the primary way of communication to transfer information. Lack of knowledge about some diseases is still a major reason for some harmful diseases spreading. The developed system includes different features that may help to communicate amongst low income people who don't even have access to the internet. Since the software system deals with Personal Health Information (PHI) it is equipped with an access control authentication system mechanism to protect privacy. The system is analyzed for performance to identify how much overhead the privacy rules impose.

  8. Multiagent based protection and control in decentralized electric power systems

    DEFF Research Database (Denmark)

    Saleem, Arshad; Lind, Morten; Veloso, Manuela

    2010-01-01

    Electric power systems are going through a major change both in their physical and control structure. A large num- ber of small and geographically dispersed power generation units (e.g., wind turbines, solar cells, plug-in electric cars) are replacing big centralized power plants. This shift has...... created interesting possibilities for application of intelligent systems such as multiagent systems for control and automation in electric power systems. This paper describes work on designing a multiagent system for protection and control of electric power distribution networks.It demonstrates how...... explicit modeling of capabilities, states, roles and role transition in agents can capture the control and automation in electric power systems. We present illustrative results from using our proposed schema in realistic simulations....

  9. FAULT-TOLERANT DESIGN FOR ADVANCED DIVERSE PROTECTION SYSTEM

    Directory of Open Access Journals (Sweden)

    YANG GYUN OH

    2013-11-01

    Full Text Available For the improvement of APR1400 Diverse Protection System (DPS design, the Advanced DPS (ADPS has recently been developed to enhance the fault tolerance capability of the system. Major fault masking features of the ADPS compared with the APR1400 DPS are the changes to the channel configuration and reactor trip actuation equipment. To minimize the fault occurrences within the ADPS, and to mitigate the consequences of common-cause failures (CCF within the safety I&C systems, several fault avoidance design features have been applied in the ADPS. The fault avoidance design features include the changes to the system software classification, communication methods, equipment platform, MMI equipment, etc. In addition, the fault detection, location, containment, and recovery processes have been incorporated in the ADPS design. Therefore, it is expected that the ADPS can provide an enhanced fault tolerance capability against the possible faults within the system and its input/output equipment, and the CCF of safety systems.

  10. Reliability analysis of the reactor protection system with fault diagnosis

    International Nuclear Information System (INIS)

    Lee, D.Y.; Han, J.B.; Lyou, J.

    2004-01-01

    The main function of a reactor protection system (RPS) is to maintain the reactor core integrity and reactor coolant system pressure boundary. The RPS consists of the 2-out-of-m redundant architecture to assure a reliable operation. The system reliability of the RPS is a very important factor for the probability safety assessment (PSA) evaluation in the nuclear field. To evaluate the system failure rate of the k-out-of-m redundant system is not so easy with the deterministic method. In this paper, the reliability analysis method using the binomial process is suggested to calculate the failure rate of the RPS system with a fault diagnosis function. The suggested method is compared with the result of the Markov process to verify the validation of the suggested method, and applied to the several kinds of RPS architectures for a comparative evaluation of the reliability. (orig.)

  11. Plutonium Protection System (PPS). Volume 2. Hardware description. Final report

    International Nuclear Information System (INIS)

    Miyoshi, D.S.

    1979-05-01

    The Plutonium Protection System (PPS) is an integrated safeguards system developed by Sandia Laboratories for the Department of Energy, Office of Safeguards and Security. The system is designed to demonstrate and test concepts for the improved safeguarding of plutonium. Volume 2 of the PPS final report describes the hardware elements of the system. The major areas containing hardware elements are the vault, where plutonium is stored, the packaging room, where plutonium is packaged into Container Modules, the Security Operations Center, which controls movement of personnel, the Material Accountability Center, which maintains the system data base, and the Material Operations Center, which monitors the operating procedures in the system. References are made to documents in which details of the hardware items can be found

  12. Protective systems and its protective switching elements on local failures of large slow-capacitor bank system

    International Nuclear Information System (INIS)

    Hasegawa, Mitsuo; Inoue, Kunikazu; Ueno, Isao.

    1994-01-01

    In various applications of pulsed power technologies, large capacitor bank systems are used to feed high current impulse to different experimental devices. The accidental electric breakdown in one of the capacitors in a parallel connection of the large bank may result in serious damages such as mechanical explosion and oil effusion or fire. In most fast banks, each unit capacitor has an output gap switch, which is expected to decouple the capacitors one another. However, no such special element is adopted usually in the slow bank system, partly because of the economical consideration. We have developed a novel and inexpensive protective element for these relatively slow capacitor banks, utilizing a concept of the enclosed type of the fast breakers. The principle of the operation of the protection elements is verified by a simulation experiment. Their practical effectiveness is also successfully demonstrated in the application to the system of the pulsed high magnetic field generator. (author)

  13. The protection system to Brazilian Nuclear Program; O sistema de protecao ao Programa Nuclear Brasileiro

    Energy Technology Data Exchange (ETDEWEB)

    Andreuzza, Mario Giussepp Santezzi Bertottelli [Secretaria de Assuntos Estrategicos (SAE), Brasilia, DF (Brazil)

    1997-12-31

    The Sistema de Protecao ao Programa Nuclear Brasileiro-SIPRON (Protection System to Brazilian Nuclear Program) was established in 1980. It is intended to accomplish in only one system, all the actions related to security and protection for Nuclear Facilities in Brazil. The author presents in detail the protection system SIPRON, describing the system structure and organization, the functions and obligations of the system involved main organizations, as well as, the system operation and behaviour during an postulated occurrence of a nuclear emergency. It is also described an Exercise that happened in June of 1997 at the Nuclear Power Plant (NPP) Angra I, after two simulated tests in December of 1996 and April of 1997. The NPP Angra I Emergency Plan Exercise was a good opportunity to test the SIPRON structure and preparedness program. It was verified, included by International Atomic Energy Agency observers, the system involved organizations effectiveness and the procedures efficacy to protect the public and the environmental. Finally, it is shown the SIPRON activities of routine, the system obstacles and the expected future performances. (author) 3 refs., 3 figs.

  14. A management system integrating radiation protection and safety supporting safety culture in the hospital

    International Nuclear Information System (INIS)

    Almen, A.; Lundh, C.

    2015-01-01

    Quality assurance has been identified as an important part of radiation protection and safety for a considerable time period. A rational expansion and improvement of quality assurance is to integrate radiation protection and safety in a management system. The aim of this study was to explore factors influencing the implementing strategy when introducing a management system including radiation protection and safety in hospitals and to outline benefits of such a system. The main experience from developing a management system is that it is possible to create a vast number of common policies and routines for the whole hospital, resulting in a cost-efficient system. One of the key benefits is the involvement of management at all levels, including the hospital director. Furthermore, a transparent system will involve staff throughout the organisation as well. A management system supports a common view on what should be done, who should do it and how the activities are reviewed. An integrated management system for radiation protection and safety includes key elements supporting a safety culture. (authors)

  15. Game theoretic analysis of physical protection system design

    International Nuclear Information System (INIS)

    Canion, B.; Schneider, E.; Bickel, E.; Hadlock, C.; Morton, D.

    2013-01-01

    The physical protection system (PPS) of a fictional small modular reactor (SMR) facility have been modeled as a platform for a game theoretic approach to security decision analysis. To demonstrate the game theoretic approach, a rational adversary with complete knowledge of the facility has been modeled attempting a sabotage attack. The adversary adjusts his decisions in response to investments made by the defender to enhance the security measures. This can lead to a conservative physical protection system design. Since defender upgrades were limited by a budget, cost benefit analysis may be conducted upon security upgrades. One approach to cost benefit analysis is the efficient frontier, which depicts the reduction in expected consequence per incremental increase in the security budget

  16. Crowbar protection system for 350 MHz Tetrode Amplifer

    International Nuclear Information System (INIS)

    Shrotriya, Sandip; Pande, Manjiri; Handu, V.K.

    2009-01-01

    In an RF amplifier, the conventional anode DC power supply has filter capacitors which have high stored energy. In the event of short circuit/arc fault across the RF tube, this stored energy may get dumped there by causing permanent damage. Hence, high power RF tubes need to be protected. This requires a fast processing circuitry that will sense the fault current, trigger the crowbar system and then divert this stored energy in to a crowbar resistance instead of RF tube. It should simultaneously turn off the HVDC anode supply. A spark gap based protection system has been designed, developed, integrated and tested with the RF amplifier. A wire burn test has been performed successfully to ensure that stored energy of the capacitor will discharge in the crowbar resistance rather than in the tube. This paper presents details about spark-gap based crowbar, triggering circuit description, wire burn test set up and results of wire burn test. (author)

  17. Tool successfully detects changes in cathodic protection system

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2011-05-15

    A new oil and gas industry tool has been developed to check if an operator's cathodic protection (CP) is effective. This inline inspection tool developed, by Baker Hughes, is called cathodic protection current measurement (CPCM). It measures how much CP current the pipeline is receiving and shows the direction of the current flowing back to the CP source. This system was used to successfully perform a full CP current inspection on a 43 mile-long pipeline in the Eastern United States. Tests identified that one rectifier was flowing current in the reverse direction from that expected and that a few areas had high current densities. The operator then changed the CP system to test the tool and results showed that the tool correctly detected the changes.

  18. Protecting sensitive systems and data in an open agency

    Science.gov (United States)

    Hunt, Douglas B.; Tompkins, Frederick G.

    1987-01-01

    This paper focuses on the policy and definitional issues associated with providing adequate and reasonable levels of protection for sensitive systems and data in an agency whose basic charter mandates the open sharing of information and transfer of technology into the market economy. An information model based on current Federal regulatory issuances is presented. A scheme for determining sensitivity levels, based on a categorization taxonomy,is provided.

  19. Regional views on the new system of radiological protection

    International Nuclear Information System (INIS)

    Yoda, N.; Fujimoto, K.; Miyamaru, K.; Lee, J.; Loy, J.; Pan, Z.Q.

    2005-01-01

    This document takes stock on the second session of the second Asian regional conference. In this session, japanese regulators, researchers and operators presented their regional views on the new ICRP recommendations. It was commonly expressed that an understanding of the background to the introduced concepts in the new recommendations is required. Other regional views from Korea, Australia and China were also expressed, based on their own regulatory system and referring to radiological protection topics in their countries. (A.L.B.)

  20. Protecting Commercial Space Systems: A Critical National Security Issue

    Science.gov (United States)

    1999-04-01

    systems. Part two will describe, at the operational level , this author’s theory for space protection and recommend a course of action to work...minimal loss of life. These factors force us to conclude this is a critical national security issue just as many in high- level government positions...Command and Staff College Operational Forces Coursebook (Academic Year 1999), 35. 3 The USCG is not a Title 10 Service, thus Posse Comitatus is not a

  1. Protection against deposits and corrosion in water systems

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, J

    1978-11-01

    Industry generally, including mining and coal preparation, are in the habit of using large amounts of untreated service water. The service water can be softened or treated with hardness stabilisers in order to prevent deposit formation and corrosion. As often as not, deposits of dirt and attack by microorganisma also have to be eliminated. The article puts forward some suggestions for practical assistance in protecting water systems against the dangers of deposits and corrosion.

  2. Upgrading of the radiation protection system at the V1 NPP

    International Nuclear Information System (INIS)

    Dobis, L.; Kaizer, J.; Svitek, J.

    2003-01-01

    The original radiation protection system at Bohunice V1 NPP from the 1970s was upgraded so as to meet current national as well as international standards. The article describes the upgrading of the radiation control system (teledosimetry, emergency measurement in the hermetic zone, liquid discharges, gaseous discharges, service water, remote measurement, hygiene loop, contamination monitoring at the controlled zone exit and activity monitoring at the NPP exit, special laundry, instrument calibration), dosimetry, software, and personnel contamination inspection/measurement. (author)

  3. Protection study of a diagnostic system for electron beam at the output of an accelerator

    International Nuclear Information System (INIS)

    Rahmani, Kaouther; Yaacoubi, Imen

    2009-01-01

    The aim of this work is the determination of the conception of a protection system dedicated to protect a diagnostic system in the CNSTN. According to this study, the suitable material for the protection against the electrons in the plexiglas and the supermalloy to protect the future diagnostic system against the magnetic field. (Author)

  4. Automated activation-analysis system

    International Nuclear Information System (INIS)

    Minor, M.M.; Hensley, W.K.; Denton, M.M.; Garcia, S.R.

    1981-01-01

    An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day. The system and its mode of operation for a large reconnaissance survey are described

  5. Physical Protection System Upgrades - Optimizing for Performance and Cost

    International Nuclear Information System (INIS)

    Hicks, Mary Jane; Bouchard, Ann M.

    1999-01-01

    CPA--Cost and Performance Analysis--is an architecture that supports analysis of physical protection systems and upgrade options. ASSESS (Analytic System and Software for Evaluating Security Systems), a tool for evaluating performance of physical protection systems, currently forms the cornerstone for evaluating detection probabilities and delay times of the system. Cost and performance data are offered to the decision-maker at the systems level and to technologists at the path-element level. A new optimization engine has been attached to the CPA methodology to automate analyses of many combinations (portfolios) of technologies. That engine controls a new analysis sequencer that automatically modifies ASSESS PPS files (facility descriptions), automatically invokes ASSESS Outsider analysis and then saves results for post-processing. Users can constrain the search to an upper bound on total cost, to a lower bound on level of performance, or to include specific technologies or technology types. This process has been applied to a set of technology development proposals to identify those portfolios that provide the most improvement in physical security for the lowest cost to install, operate and maintain at a baseline facility

  6. Some Current Problems in Optimisation of Radiation Protection System

    International Nuclear Information System (INIS)

    Franic, Z.; Prlic, I.

    2001-01-01

    Full text: The current system of radiation protection is generally based on recommendations promulgated in the International Commission on Radiological Protection (ICRP) publication 60. These principles and recommendations were subsequently adopted by the International Atomic Energy Agency (IAEA) in International Basic Safety Standards for Protection against Ionising Radiation and for the Safety of Radiation Sources (BSS). However, in recent years certain problems have arisen such as application of risk factors at low doses, use and interpretation of a collective dose, concept of dose commitment, optimisation of all types of occupational exposure and practices, implementation of ALARA approach in the common occupational as well as in quite complex situations etc. In this paper are presented some of the issues that have to be addressed in the development of the new ICRP Recommendations that are planned to be developed in next four or five years. As the new radiation protection philosophy shifts from society-based control of stochastic risks to an individual-based policy, consequently it will require introduction of modified approach to optimisation process and probably introduction of some new dosimetric quantities. (author)

  7. Narrative Inquiry With Activity Systems

    Directory of Open Access Journals (Sweden)

    Lisa C. Yamagata-Lynch

    2017-04-01

    Full Text Available The goal of this article is to introduce activity systems as a methodological tool in narrative inquiry to gain a holistic understanding of socially shared experiences from an examination of documents. The research question was how can qualitative researchers use activity systems as a tool for engaging in narrative inquiry of socially shared experiences to uncover new meanings by constructing a story? In this article, we share a sample analysis of our experience relying on documents and media as a form of narrative to begin to understand the socially shared human activity associated with net neutrality and its potential impact on U.S. residents. We end this article with reflections of lessons learned from our activity systems guided story construction process.

  8. Active Response Gravity Offload System

    Science.gov (United States)

    Valle, Paul; Dungan, Larry; Cunningham, Thomas; Lieberman, Asher; Poncia, Dina

    2011-01-01

    The Active Response Gravity Offload System (ARGOS) provides the ability to simulate with one system the gravity effect of planets, moons, comets, asteroids, and microgravity, where the gravity is less than Earth fs gravity. The system works by providing a constant force offload through an overhead hoist system and horizontal motion through a rail and trolley system. The facility covers a 20 by 40-ft (approximately equals 6.1 by 12.2m) horizontal area with 15 ft (approximately equals4.6 m) of lifting vertical range.

  9. Adaptive intelligent power systems: Active distribution networks

    International Nuclear Information System (INIS)

    McDonald, Jim

    2008-01-01

    Electricity networks are extensive and well established. They form a key part of the infrastructure that supports industrialised society. These networks are moving from a period of stability to a time of potentially major transition, driven by a need for old equipment to be replaced, by government policy commitments to cleaner and renewable sources of electricity generation, and by change in the power industry. This paper looks at moves towards active distribution networks. The novel transmission and distribution systems of the future will challenge today's system designs. They will cope with variable voltages and frequencies, and will offer more flexible, sustainable options. Intelligent power networks will need innovation in several key areas of information technology. Active control of flexible, large-scale electrical power systems is required. Protection and control systems will have to react to faults and unusual transient behaviour and ensure recovery after such events. Real-time network simulation and performance analysis will be needed to provide decision support for system operators, and the inputs to energy and distribution management systems. Advanced sensors and measurement will be used to achieve higher degrees of network automation and better system control, while pervasive communications will allow networks to be reconfigured by intelligent systems

  10. Establish an e-learning system for radiation protection as a teaching aid at STTN

    International Nuclear Information System (INIS)

    Supriyono; Joko Susilo; Muhtadan

    2013-01-01

    A system e-learning of radiation protection lesson as a teaching aids has built, for lectures activities and teaching aids in deepening the course materials of radiation protection in STTN. This system contains learning materials of radiation protection lesson, they are : Basic radiation physics, Dosimetry, basic radiation protection, radiation measuring equipment, effects of radiation, radioactive waste management, transport of radioactive substances, etc. In building of this system, Moodle platform is used with the support from some softwares, they are : Apache web server, MySql, PHP in local host computer that use XAMPP 1.8.1. The one who has rights to access this system is an admin who has obligation to manage the system and to edit, add, and remove the materials and users that consist of teachers, students, and operators who have access to use that system, as a learning aids as well as teaching aids. The materials of E-learning displayed in the forms : lesson materials, animations, pictures, and simulations. The results of this system show that E-learning able to works well as a teaching aids. With this teaching aids, we hope it will increase the quality of learning and teaching process in STTN and also it will increase the accreditation of STTN. (author)

  11. The influence of increased cross-linker chain length in thermosensitive microspheres on potential sun-protection activity.

    Science.gov (United States)

    Musiał, Witold; Kokol, Vanja; Voncina, Bojana

    2010-01-01

    The sun protection should involve substances with protecting activity against both UVB and UVA radiation. In this research the evaluation of thermosensitive microspheres as potential molecules for sunscreen formulations was approached, using modified Boots star rating system. The microspheres, thermosensitive N-isopropylacrylamide derivatives, have potential protecting activity against UV radiation. The MX and DX microspheres, with ethylene glycol dimethacrylate and diethylene glycol dimethacrylate crosslinker respectively, due to theirs thermosensitivity exhibit increase in protecting activity against UV radiation when heated to 45 degrees C. The MX microspheres have higher increase in terms of UV absorbance, comparing to DX microspheres, when heated in the 25 degrees C to 45 degrees C range. Studied microspheres have high potential for application as components of sun-screens used in elevated temperatures.

  12. Model Based Cyber Security Analysis for Research Reactor Protection System

    International Nuclear Information System (INIS)

    Sho, Jinsoo; Rahman, Khalil Ur; Heo, Gyunyoung; Son, Hanseong

    2013-01-01

    The study on the qualitative risk due to cyber-attacks into research reactors was performed using bayesian Network (BN). This was motivated to solve the issues of cyber security raised due to digitalization of instrumentation and control (I and C) system. As a demonstrative example, we chose the reactor protection system (RPS) of research reactors. Two scenarios of cyber-attacks on RPS were analyzed to develop mitigation measures against vulnerabilities. The one is the 'insertion of reactor trip' and the other is the 'scram halt'. The six mitigation measures are developed for five vulnerability for these scenarios by getting the risk information from BN

  13. Layered virus protection for the operations and administrative messaging system

    Science.gov (United States)

    Cortez, R. H.

    2002-01-01

    NASA's Deep Space Network (DSN) is critical in supporting the wide variety of operating and plannedunmanned flight projects. For day-to-day operations it relies on email communication between the three Deep Space Communication Complexes (Canberra, Goldstone, Madrid) and NASA's Jet Propulsion Laboratory. The Operations & Administrative Messaging system, based on the Microsoft Windows NTand Exchange platform, provides the infrastructure that is required for reliable, mission-critical messaging. The reliability of this system, however, is threatened by the proliferation of email viruses that continue to spread at alarming rates. A layered approach to email security has been implemented across the DSN to protect against this threat.

  14. Lemon juice has protective activity in a rat urolithiasis model

    Directory of Open Access Journals (Sweden)

    Oussama Abdelkhalek

    2007-10-01

    Full Text Available Abstract Background The use of herbal medicines (medicinal plants or phytotherapy has recently gained popularity in Europe and the United States. Nevertheless the exact mechanism of the preventive effects of these products is still far to be clearly established, being its knowledge necessary to successfully apply these therapies to avoid stone formation. Methods The effect of oral lemon juice administration on calcium oxalate urolithiasis was studied in male Wistar rats. Rats were rendered nephrolithic by providing drinking water containing 0.75% ethylene glycol [v/v] (EG and 2% ammonium chloride [w/v] (AC for 10 days. In addition to EG/AC treatment, three groups of rats were also gavage-administered solutions containing 100%, 75% or 50% lemon juice [v/v] (6 μl solution/g body weight. Positive control rats were treated with EG/AC but not lemon juice. Negative control rats were provided with normal drinking water, and were administered normal water by gavage. Each group contained 6 rats. After 10 days, serum samples were collected for analysis, the left kidney was removed and assessed for calcium levels using flame spectroscopy, and the right kidney was sectioned for histopathological analysis using light microscopy. Results Analysis showed that the rats treated with EG/AC alone had higher amounts of calcium in the kidneys compared to negative control rats. This EG/AC-induced increase in kidney calcium levels was inhibited by the administration of lemon juice. Histology showed that rats treated with EG/AC alone had large deposits of calcium oxalate crystals in all parts of the kidney, and that such deposits were not present in rats also treated with either 100% or 75% lemon juice. Conclusion These data suggest that lemon juice has a protective activity against urolithiasis.

  15. Information system development activities and inquiring systems

    DEFF Research Database (Denmark)

    Carugati, Andrea

    2008-01-01

    This article presents a framework that maps information system development (ISD) activities on systems for the creation of knowledge. This work addresses the relevant and persisting problem of improving the chances of ISD success. The article builds upon previous research on knowledge aspects...... based on ISD literature and on Churchman's (1971) inquiring systems. The second part presents the use of the framework in an ISD project. The case is used to show the applicability of the framework and to highlight the advantages of this approach. The main theoretical implication is that the framework...

  16. Dysbaric osteonecrosis (caisson disease of bone): are active oxygen species and the endocrine system responsible, and can control of the production of free radicals and their reaction products confer protection?

    Science.gov (United States)

    Jones, G R

    1987-01-01

    The development of osteonecrosis after exposure to altered air pressures is consistent with cellular injury brought about by active oxygen species. The syndrome is considered to arise as a result of an unusual combination of circumstances in which hyperoxia itself, together with the additive responses of the endocrine system to hyperoxia, hypothermia and exertion, each appear to play a part; the net result is thought to increase the mitochondrial generation of superoxide. It is suggested that effective prophylaxis may be possible primarily by establishing a nutritional status that is adequate to ensure that the functional activities of radical-scavenging systems are not hampered by deficiencies either of essential trace elements or of vitamin E. Pharmacological pretreatments designed both to decrease excessive levels of superoxide through increased catalysis of anionic dismutation and to attenuate enzyme-dependent peroxidation may provide an additional line of defence.

  17. A development of digital plant protection system architecture

    International Nuclear Information System (INIS)

    Seong, S. H.; Park, H. Y.; Kim, D. H.; Seo, Y. S.; Gu, I. S.

    2000-01-01

    The digital plant protection system (DPPS) which have a large number of advantages compared to current analog protection system has been developed in various field. The major disadvantages of digital system are, however, vulnerable to faults of processor and software. To overcome the disadvantages, the concept of segment and partition in a channel has been developed. Each segment in a channel is divided from sensor to reactor trip and engineered safety features, which is based on the functional diversity of input signals against the various plant transient phenomena. Each partition allocates the function module to an independent processing module in order to process and isolate the faults of each module of a segment. A communication system based on the deterministic protocol with the predictable and hard real-time characteristics has been developed in order to link the various modules within a segment. The self-diagnostics including online test and periodic test procedures are developed in order to increase the safety, reliability and availability of DPPS. The developed DPPS uses the off-the-shelf DSP (digital signal processor) and adopts VME bus architecture, which have sufficient operation experience in the industry. The verification and validation and quality assurance of software has been developed and the architecture and protocol of deterministic communication system has been researched

  18. Qualification issues for advanced light-water reactor protection systems

    International Nuclear Information System (INIS)

    Korsah, K.; Clark, R.L.; Antonescu, C.

    1993-01-01

    The instrumentation and control (I ampersand C) systems in advanced reactors will make extensive use of digital controls, microprocessors, multiplexing, and fiber optic transmission. Elements of these advances in I ampersand C have been implemented on some current operating plants. However, the widespread use of the above technologies, as well as the use of artificial intelligence with minimum reliance on human operator control of reactors, highlights the need to develop standards for qualifying the I ampersand C used in the next generation of nuclear power plants. As a first step in this direction, the protection system I ampersand C for present-day plants was compared to that proposed for advanced light-water reactors (ALWRs). An evaluation template was developed by assembling a configuration of a safety channel instrument string for a generic ALWR, then comparing the impact of environmental stressors on that string to their effect on an equivalent instrument string from an existing light-water reactor. The template was then used to suggest a methodology for the qualification of microprocessor-based protection systems. The methodology identifies standards/regulatory guides (or lack thereof) for the qualification of microprocessor-based safety I ampersand C systems. This approach addresses in part issues raised in NRC policy document SECY-91-292, which recognizes that advanced I ampersand C systems for the nuclear industry are ''being developed without consensus standards. as the technology available for design is ahead of the technology that is well understood through experience and supported by application standards.''

  19. Development of a Smart Residential Fire Protection System

    OpenAIRE

    Juhwan Oh; Zhongwei Jiang; Henry Panganiban

    2013-01-01

    Embedded system is applied for the development of smart residential fire detection and extinguishing system. Wireless communication capability is integrated into various fire sensors and alarm devices. The system activates the fire alarm to warn occupants, executes emergency and rescue calls to remote residents and fire-fighting facility in an intelligent way. The effective location of extra-sprinklers within the space of interest for the fire extinguishing system is also investigated. Actual...

  20. Evaluation of road-transit physical protection systems

    International Nuclear Information System (INIS)

    Gallagher, R.J.; Keeton, S.C.; Stimmell, K.G.; DeLaquil, P. III.

    1978-05-01

    To assess the overall effectiveness of a transportation physical protection system, computer codes which simulate armed attacks have been developed and are being used to examine a range of issues associated with road transportation systems. The paper discusses the purpose and features of three of these codes, SOURCE (which simulates the initial ambush), SABRES I (which covers the battle) and BARS (which treats the penetration of protective cargo barriers). The use of these methodologies to evaluate the value of additional vehicles, guards, armor and alternative tactics or equipment as a means of improving convoy security has recently been completed. The results which are presented demonstrate that the protection offered by the present commercial regulations for guards and vehicles is probably marginal. This could be substantially increased by the addition of armor to close escort vehicles instead of just the transporter and the use of appropriate tactics. Against the baseline threat of adversaries armed with M-16's, observation and harassment from a modest distance until re-enforcements arrive appears preferable to aggressive assault by the ambushed guard force