WorldWideScience

Sample records for active power line

  1. EVALUATING DEGREE OF ACTIVE POWER LOSSES REDUCTION IN THE ELECTRIC POWER LINES WITH REACTIVE POWER COMPENSATION

    Directory of Open Access Journals (Sweden)

    V. N. Radkevich

    2016-01-01

    Full Text Available The paper considers evaluation procedure for the degree of active power losses reduction in the power transmission lines under 1 kV and 6–10 kV of the systems of electric power supply of industrial enterprises with compensating installations mounted at the side of the customer. The capacitor installations conform to the applied voltage level and factor in dielectric losses in the capacitors. The voltage at the compensating device terminal changes from 0.95 to 1.05 of the capacitors nominal voltage. The study did not account for reactive power losses in the line, nor did it for its charge capacity, conditioned by relative shortness of the cable lines generally operating in the mains of industrial enterprises. For this reason, the quantities of reactive power being consumed and generated by the transmission line are negligible and do not significantly affect the reactive power flux. The researchers obtain functional relations that allow estimating the degree of power loss reduction in the transmission line factoring in its explicit initial data. They perform mathematical analysis of the obtained functional relations and study the function by means of derivatives. The function extremum points are found as well as the intervals of its increment and decrement. A graphical research of the obtained functional relation is performed. It is ascertained that reduction of the active power losses is contingent on the line and the capacitor-installation engineering factors, the electrical energy consumer reactive load value as well as the voltage applied to the capacitor installation. The functional relations presented in the article can be employed in scoping calculation necessary for decision making on the reactive power compensation in systems of the industrial facilities electric power supply. Their account will allow a more accurate estimate of technical and economic effect of the capacitor bank installation in the electrical mains under 1 kV and 6

  2. Active power line conditioners design, simulation and implementation for improving power quality

    CERN Document Server

    Revuelta, Patricio Salmeron; Litrán, Salvador Pérez

    2015-01-01

    Active Power Line Conditioners: Design, Simulation and Implementation for Improving Power Quality presents a rigorous theoretical and practical approach to active power line conditioners, one of the subjects of most interest in the field of power quality. Its broad approach offers a journey that will allow power engineering professionals, researchers, and graduate students to learn more about the latest landmarks on the different APLC configurations for load active compensation. By introducing the issues and equipment needs that arise when correcting the lack of power quality in power grids

  3. Active Power Flow Optimization of Industrial Power Supply with Regard to the Transmission Line Conductor Heating

    Directory of Open Access Journals (Sweden)

    Leyzgold D.Yu.

    2015-04-01

    Full Text Available This article studies the problem of the transmission line conductor heating effect on the active power flows optimization in the local segment of industrial power supply. The purpose is to determine the optimal generation rating of the distributed power sources, in which the power flow values will correspond to the minimum active power losses in the power supply. The timeliness is the need to define the most appropriate rated power values of distributed sources which will be connected to current industrial power supply. Basing on the model of active power flow optimization, authors formulate the description of the nonlinear transportation problem considering the active power losses depending on the transmission line conductor heating. Authors proposed a new approach to the heating model parameters definition based on allowable current loads and nominal parameters of conductors as part of the optimization problem. Analysis of study results showed that, despite the relatively small active power losses reduction to the tune 0,45% due to accounting of the conductors heating effect for the present configuration of power supply, there are significant fluctuations in the required generation rating in nodes of the network to 9,32% within seasonal changes in the outer air temperature. This fact should be taken into account when selecting the optimum power of distributed generation systems, as exemplified by an arbitrary network configuration.

  4. Electric Power Transmission Lines

    Data.gov (United States)

    Department of Homeland Security — Transmission Lines are the system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power...

  5. Active high-power RF pulse compression using optically switched resonant delay lines

    International Nuclear Information System (INIS)

    Tantawi, S.G.; Ruth, R.D.; Vlieks, A.E.

    1996-11-01

    The authors present the design and a proof of principle experimental results of an optically controlled high power rf pulse compression system. The design should, in principle, handle few hundreds of Megawatts of power at X-band. The system is based on the switched resonant delay line theory. It employs resonant delay lines as a means of storing rf energy. The coupling to the lines is optimized for maximum energy storage during the charging phase. To discharge the lines, a high power microwave switch increases the coupling to the lines just before the start of the output pulse. The high power microwave switch, required for this system, is realized using optical excitation of an electron-hole plasma layer on the surface of a pure silicon wafer. The switch is designed to operate in the TE 01 mode in a circular waveguide to avoid the edge effects present at the interface between the silicon wafer and the supporting waveguide; thus, enhancing its power handling capability

  6. ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIOR

    Directory of Open Access Journals (Sweden)

    Rimsky V.X.

    2008-04-01

    Full Text Available Exact formulas for calculation of limiting values of transmitted capacity and efficiency of lines of a variable voltage with active loading on the reception end are resulted. Critical resistance and losses of capacity are determined depending on length Air-lines of an electricity transmission of a class of a voltage 500 … 750 kV. Emergency operation in the loaded electricity transmission is investigated.

  7. SYNTHESIS OF ACTIVE SCREENING SYSTEM OF MAGNETIC FIELD OF HIGH VOLTAGE POWER LINES OF DIFFERENT DESIGN TAKING INTO ACCOUNT SPATIAL AND TEMPORAL DISTRIBUTION OF MAGNETIC FIELD

    Directory of Open Access Journals (Sweden)

    B.I. Kuznetsov

    2017-04-01

    Full Text Available Purpose. Analyze the spatial and temporal distribution of the magnetic field of high voltage power lines with different design allowing and development of recommendations for the design of active screening systems by magnetic field of high voltage power lines. Methodology. Analysis of the spatial and temporal distribution of the magnetic field of high voltage power lines of different design allowing is made on the basis of Maxwell's equations solutions in the quasi-stationary approximation. Determination of the number, configuration, spatial arrangement and the compensation coil currents is formulated in the form of multiobjective optimization problem that is solved by multi-agent multiswarm stochastic optimization based on Pareto optimal solutions. Results of active screening system for the synthesis of various types of transmission lines with different numbers of windings controlled. The possibility of a significant reduction in the level of the flux density of the magnetic field source within a given region of space. Originality. For the first time an analysis of the spatial and temporal distribution of the magnetic field of power lines with different types and based on findings developed recommendations for the design of active screening system by magnetic field of high voltage power lines. Practical value. Practical recommendations on reasonable choice of the number and spatial arrangement of compensating windings of active screening system by magnetic field of high voltage power lines of different design allowing for the spatial and temporal distribution of the magnetic field. Results of active screening system synthesis of the magnetic field of industrial frequency generated by single-circuit 110 kV high voltage power lines with the supports have 330 - 1T «triangle» rotating magnetic field with full polarization in a residential five-storey building, located near the power lines. The system contains three compensating coil and reduces

  8. Understanding broadband over power line

    CERN Document Server

    Held, Gilbert

    2006-01-01

    Understanding Broadband over Power Line explores all aspects of the emerging technology that enables electric utilities to provide support for high-speed data communications via their power infrastructure. This book examines the two methods used to connect consumers and businesses to the Internet through the utility infrastructure: the existing electrical wiring of a home or office; and a wireless local area network (WLAN) access point.Written in a practical style that can be understood by network engineers and non-technologists alike, this volume offers tutorials on electric utility infrastru

  9. Signal Transmission on Power Lines

    DEFF Research Database (Denmark)

    Dalby, Arne Brejning

    1997-01-01

    In the analysis of power-line networks over a large frequency span, the time-domain method used in programs like EMTP (Electromagnetic Time domain Program) can not be used. A more rigorous analysis method must be employed. The correct analysis method (assuming TEM-mode propagation) for multiple....... An approximate analysis method must be usedIn this paper it is shown that an eigenvectormatrix, that is the propagation modes, can be chosen almost arbitrarily if the frequency interval of interest lies below the frequency, where the line length is about 1/3 times the wavelength for the propagation mode...... with the lowest phase velocity. The propagation constants corresponding to the chosen eigenvector matrix (the quasi modes) are found iteratively, which is a much simpler procedure than finding the eigenvalues....

  10. Manipulating the mitochondria activity in human hepatic cell line Huh7 by low-power laser irradiation

    Science.gov (United States)

    Lynnyk, Anna; Lunova, Mariia; Jirsa, Milan; Egorova, Daria; Kulikov, Andrei; Kubinová, Šárka; Lunov, Oleg; Dejneka, Alexandr

    2018-01-01

    Low-power laser irradiation of red light has been recognized as a promising tool across a vast variety of biomedical applications. However, deep understanding of the molecular mechanisms behind laser-induced cellular effects remains a significant challenge. Here, we investigated mechanisms involved in the death process in human hepatic cell line Huh7 at a laser irradiation. We decoupled distinct cell death pathways targeted by laser irradiations of different powers. Our data demonstrate that high dose laser irradiation exhibited the highest levels of total reactive oxygen species production, leading to cyclophilin D-related necrosis via the mitochondrial permeability transition. On the contrary, low dose laser irradiation resulted in the nuclear accumulation of superoxide and apoptosis execution. Our findings offer a novel insight into laser-induced cellular responses, and reveal distinct cell death pathways triggered by laser irradiation. The observed link between mitochondria depolarization and triggering ROS could be a fundamental phenomenon in laser-induced cellular responses. PMID:29541521

  11. Numerical Calculation of Overhead Power Lines Dynamics

    Directory of Open Access Journals (Sweden)

    Gogola Roman

    2016-11-01

    Full Text Available This paper contains results of transient analysis of airflow around the ACSR power line cross-section in unsymmetric multi-span. The forces applied to the power line are obtained from CFD simulations, where the wind induced vibration is studied. Effect of these forces to the maximal displacement of the power line and the maximal mechanical forces in the points of attachment are studied and evaluated.

  12. Power line communications theory and applications for narrowband and broadband communications over power lines

    CERN Document Server

    Ferreira, Hendrik C; Newbury, John; Swart, Theo G

    2010-01-01

    Power Line Communications (PLC) is a promising emerging technology, which has attracted much attention due to the wide availability of power distribution lines. This book provides a thorough introduction to the use of power lines for communication purposes, ranging from channel characterization, communications on the physical layer and electromagnetic interference, through to protocols, networks, standards and up to systems and implementations. With contributions from many of the most prominent international PLC experts from academia and industry, Power Line Communications brings togeth

  13. Elk and plants thrive near power lines

    Energy Technology Data Exchange (ETDEWEB)

    Lustre, L.

    1997-11-01

    Butterflies and elk gather in clearings near power line right-of-ways and on the edges of such clearings, where the wild flowers and plants that have widely disappeared as a result of intensive farming and subsurface drainage of fields have found a good habitat. Ornamental coniferous trees, various herbs and assorted berries do well and can be harvested near power lines from woodland clearings once thought unfit for cultivation. IVS, the nationwide network company, takes part in many projects aiming both to increase productive utilization of land areas under power lines and to promote biodiversity

  14. Controlled Compact High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Postolati V.

    2016-04-01

    Full Text Available Nowadays modern overhead transmission lines (OHL constructions having several significant differences from conventional ones are being used in power grids more and more widely. Implementation of compact overhead lines equipped with FACTS devices, including phase angle regulator settings (compact controlled OHL, appears to be one of the most effective ways of power grid development. Compact controlled AC HV OHL represent a new generation of power transmission lines embodying recent advanced achievements in design solutions, including towers and insulation, together with interconnection schemes and control systems. Results of comprehensive research and development in relation to 110–500kV compact controlled power transmission lines together with theoretical basis, substantiation, and methodological approaches to their practical application are presented in the present paper.

  15. Transmission Line Adapted Analytical Power Charts Solution

    Science.gov (United States)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2017-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  16. Circuit for Communication Over Power Lines

    Science.gov (United States)

    Krasowski, Michael J.; Prokop, Normal F.; Greer, Lawrence C., III; Nappier, Jennifer

    2011-01-01

    Many distributed systems share common sensors and instruments along with a common power line supplying current to the system. A communication technique and circuit has been developed that allows for the simple inclusion of an instrument, sensor, or actuator node within any system containing a common power bus. Wherever power is available, a node can be added, which can then draw power for itself, its associated sensors, and actuators from the power bus all while communicating with other nodes on the power bus. The technique modulates a DC power bus through capacitive coupling using on-off keying (OOK), and receives and demodulates the signal from the DC power bus through the same capacitive coupling. The circuit acts as serial modem for the physical power line communication. The circuit and technique can be made of commercially available components or included in an application specific integrated circuit (ASIC) design, which allows for the circuit to be included in current designs with additional circuitry or embedded into new designs. This device and technique moves computational, sensing, and actuation abilities closer to the source, and allows for the networking of multiple similar nodes to each other and to a central processor. This technique also allows for reconfigurable systems by adding or removing nodes at any time. It can do so using nothing more than the in situ power wiring of the system.

  17. Power Line Communications for Smart Grid Applications

    Directory of Open Access Journals (Sweden)

    Lars Torsten Berger

    2013-01-01

    Full Text Available Power line communication, that is, using the electricity infrastructure for data transmission, is experiencing a renaissance in the context of Smart Grid. Smart Grid objectives include the integration of intermittent renewable energy sources into the electricity supply chain, securing reliable electricity delivery, and using the existing electrical infrastructure more efficiently. This paper surveys power line communications (PLCs in the context of Smart Grid. The specifications G3-PLC, PRIME, HomePlug Green PHY, and HomePlug AV2, and the standards IEEE 1901/1901.2 and ITU-T G.hn/G.hnem are discussed.

  18. Bird nesting on an Athabasca power line structure

    International Nuclear Information System (INIS)

    Stedwill, R.J.

    1989-01-01

    SaskPower has recently completed its 400 km Athabasca power line, and is evaluating the predicted environmental impact of the line on the resident population of bald eagles and other raptors. During construction of the line, five major types of impact associated with the line were addressed. Minor route adjustments were made to by-pass nests of bald eagles and osprey to minimize impact of construction on breeding. The proximity of the power line to cliff faces and the north shore of lake Athabasca was maximized, and frequency of stream crossings and proximity to rapids were minimized. Route adjustments were made to ensure that the line was at least 1.6 km from bald eagle nest sites. As structures of the main 115 kV power line allow a minimum separation between conductors and grounded spars of 1.6 m, and between conductors of 4.6 m, electrocution was not considered to be a significant risk. However, on the 25 kV power line in regions of known bald eagle activity and in close proximity to bodies of water, provision was made for special structures to allow birds to perch without danger of electrocution. It was concluded that the resident population of raptors will probably be enhanced, particularly in areas not previously utilized. 8 refs., 5 figs

  19. Power flow studies of magnetically insulated lines

    International Nuclear Information System (INIS)

    McDaniel, D.H.; Poukey, J.W.; Bergeron, K.D.; VanDevender, J.P.; Johnson, D.L.

    1977-01-01

    The designs for relativistic electron beam accelerators with power levels of 20 to 100 TW are greatly restricted by the inductance of a single diode of reasonable size. This fact leads to modular designs of very large accelerators. One concept uses several small insulators at a large radius arranged around the accelerator center. The total effective inductance is then low, but the energy must then be transported by self-magnetic insulated vacuum lines to the target volume. A triplate vacuum line configuration eases many mechanical support problems and allows more A-K gaps or feeds to be packaged around a given radius. This type of vacuum transmission line was chosen for initial experiments at Sandia. The experiments were conducted on the MITE (Magnetically Insulated Transmission Experiment) accelerator. The water pulse forming lines are connected to a vacuum triplate line through a conventional stacked insulator. Diagnostics on the experiment consisted of: (1) input V; (2) input I; (3) I monitors at the input, middle, and output of both the center conductor and ground plane of the transmission line; (4) magnetic energy analyzer to view peak electron energy in the A-K gap; (5) calorimetry; and (6) Faraday cups to look at electron current flowing across the transmission line. The main goal of the experiment is to obtain input impedance of the transmission line as a function of voltage and to measure electron loss currents. These measurements are compared to theoretical models for the input impedance and energy losses

  20. High power RF transmission line component development

    International Nuclear Information System (INIS)

    Hong, B. G.; Hwang, C. K.; Bae, Y. D.; Yoon, J. S.; Wang, S. J.; Gu, S. H.; Yang, J. R.; Hahm, Y. S.; Oh, G. S.; Lee, J. R.; Lee, W. I.; Park, S. H.; Kang, M. S.; Oh, S. H.; Lee, W.I.

    1999-12-01

    We developed the liquid stub and phase shifter which are the key high RF power transmission line components. They show reliable operation characteristics and increased insulation capability, and reduced the size by using liquid (silicon oil, dielectric constant ε=2.72) instead of gas for insulating dielectric material. They do not have finger stock for the electric contact so the local temperature rise due to irregular contact and RF breakdown due to scratch in conductor are prevented. They can be utilized in broadcasting, radar facility which require high RF power transmission. Moreover, they are key components in RF heating system for fusion reactor. (author)

  1. High power RF transmission line component development

    Energy Technology Data Exchange (ETDEWEB)

    Hong, B. G.; Hwang, C. K.; Bae, Y. D.; Yoon, J. S.; Wang, S. J.; Gu, S. H.; Yang, J. R.; Hahm, Y. S.; Oh, G. S.; Lee, J. R.; Lee, W. I.; Park, S. H.; Kang, M. S.; Oh, S. H.; Lee, W.I

    1999-12-01

    We developed the liquid stub and phase shifter which are the key high RF power transmission line components. They show reliable operation characteristics and increased insulation capability, and reduced the size by using liquid (silicon oil, dielectric constant {epsilon}=2.72) instead of gas for insulating dielectric material. They do not have finger stock for the electric contact so the local temperature rise due to irregular contact and RF breakdown due to scratch in conductor are prevented. They can be utilized in broadcasting, radar facility which require high RF power transmission. Moreover, they are key components in RF heating system for fusion reactor. (author)

  2. Raptor nest management on power lines

    Energy Technology Data Exchange (ETDEWEB)

    Harness, R.E. [EDM International Inc., Fort Collins, CO (United States)

    2005-07-01

    Many utilities in South Africa are now implementing labor-intensive methods to combat raptor nesting on power transmission lines. Methods have typically included direct nest removal and trimming of nest materials. However, the process is often unsuccessful, and utilities are now learning to accommodate the raptor nests. This paper argued that managing nests on utility structures has solved many operational problems and has resulted in positive publicity for many line operators. Nest management options included the use of stick deflectors to prevent nest material from accumulating during initial nest construction, as well as encouraging raptors to shift their efforts to a more suitable location. Raptors will often accept alternative nesting platforms, and taller, surrogate nesting poles can be placed next to distribution line structures. Elevated platforms can also be placed on problematic distribution structures, but may result in birds coming into contact with unprotected equipment. It was concluded that a successful nest management program includes plans to make nearby lines safe for raptors and to prevent their electrocution. Providing nests with bird-friendly utility configurations can result in electric facilities enhancing wild raptor populations without impacting power reliability. 14 refs., 9 figs.

  3. Line Capacity Expansion and Transmission Switching in Power Systems With Large-Scale Wind Power

    DEFF Research Database (Denmark)

    Villumsen, Jonas Christoffer; Bronmo, Geir; Philpott, Andy B.

    2013-01-01

    In 2020 electricity production from wind power should constitute nearly 50% of electricity demand in Denmark. In this paper we look at optimal expansion of the transmission network in order to integrate 50% wind power in the system, while minimizing total fixed investment cost and expected cost...... of power generation. We allow for active switching of transmission elements to reduce congestion effects caused by Kirchhoff's voltage law. Results show that actively switching transmission lines may yield a better utilization of transmission networks with large-scale wind power and increase wind power...

  4. Acoustic power balance in lined ducts

    Science.gov (United States)

    Eversman, W.

    1979-01-01

    It is shown that the two common definitions of acoustic energy density and intensity in uniform unlined ducts carrying uniform flow are compatible to the extent that both energy densities can be used in an appropriate variational principle to derive the convected wave equation. When the duct walls are lined both energy densities must be modified to account for the wall energy density. This results in a new energy conservation equation which utilizes a modified definition of axial power and accounts for wall dissipation. Computations in specific cases demonstrate the validity of the modified acoustic energy relation.

  5. Discretionary power on the front-line

    DEFF Research Database (Denmark)

    Sanden, Guro Refsum; Lønsmann, Dorte

    2018-01-01

    This article investigates the communication practices used by front-line employees to cross language boundaries in the context of English language policies implemented by the management of three multinational corporations headquartered in Scandinavia. Based on an analysis of interview and document...... data, our findings show that employees face a number of different language boundaries in their everyday work, and that ad hoc and informal solutions in many cases are vital for successful cross-language communication. We introduce the concept of discretionary power to explain how and why front...

  6. Discretionary Power on the Front Line

    DEFF Research Database (Denmark)

    Sanden, Guro Refsum; Lønsmann, Dorte

    2018-01-01

    This paper investigates the communication practices used by front-line employees to cross language boundaries in the context of English language policies implemented by the management of three multinational corporations (MNCs) headquartered in Scandinavia. Based on an analysis of interview...... and document data, our findings show that employees face a number of different language boundaries in their everyday work, and that ad hoc and informal solutions in many cases are vital for successful cross-language communication. We introduce the concept of 'discretionary power' to explain how and why front...

  7. Apparatus and Method for Communication over Power Lines

    Science.gov (United States)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, III, Lawrence C. (Inventor); Nappier, Jennifer M. (Inventor)

    2017-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  8. UAV Low Altitude Photogrammetry for Power Line Inspection

    Directory of Open Access Journals (Sweden)

    Yong Zhang

    2017-01-01

    Full Text Available When the distance between an obstacle and a power line is less than the discharge distance, a discharge arc can be generated, resulting in the interruption of power supplies. Therefore, regular safety inspections are necessary to ensure the safe operation of power grids. Tall vegetation and buildings are the key factors threatening the safe operation of extra high voltage transmission lines within a power line corridor. Manual or laser intensity direction and ranging (LiDAR based inspections are time consuming and expensive. To make safety inspections more efficient and flexible, a low-altitude unmanned aerial vehicle (UAV remote-sensing platform, equipped with an optical digital camera, was used to inspect power line corridors. We propose a semi-patch matching algorithm based on epipolar constraints, using both the correlation coefficient (CC and the shape of its curve to extract three dimensional (3D point clouds for a power line corridor. We use a stereo image pair from inter-strip to improve power line measurement accuracy by transforming the power line direction to an approximately perpendicular to epipolar line. The distance between the power lines and the 3D point cloud is taken as a criterion for locating obstacles within the power line corridor automatically. Experimental results show that our proposed method is a reliable, cost effective, and applicable way for practical power line inspection and can locate obstacles within the power line corridor with accuracy better than ±0.5 m.

  9. Transmission Lines or Poles, Electric - VOLUSIA COUNTY MAJOR POWER LINES (Arcs)

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Volusia County Power Line data was aggregated by using parcel data and visual inspection of 2005 aerial photography to determine centerline of Power Lines Right of...

  10. AUTOMATIC RAILWAY POWER LINE EXTRACTION USING MOBILE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    S. Zhang

    2016-06-01

    Full Text Available Research on power line extraction technology using mobile laser point clouds has important practical significance on railway power lines patrol work. In this paper, we presents a new method for automatic extracting railway power line from MLS (Mobile Laser Scanning data. Firstly, according to the spatial structure characteristics of power-line and trajectory, the significant data is segmented piecewise. Then, use the self-adaptive space region growing method to extract power lines parallel with rails. Finally use PCA (Principal Components Analysis combine with information entropy theory method to judge a section of the power line whether is junction or not and which type of junction it belongs to. The least squares fitting algorithm is introduced to model the power line. An evaluation of the proposed method over a complicated railway point clouds acquired by a RIEGL VMX450 MLS system shows that the proposed method is promising.

  11. Avian mortality rates on a power line near Kampala, Uganda

    African Journals Online (AJOL)

    power line carried on tall metal pylons, and a smaller 33-kV line, with three conduc- tors supported on wooden poles, ... able literature on bird mortality associated with power lines (e.g. Lehman et al. 2005,. Jenkins et al. 2010, Edison .... the conductor wires would have been hard to see. Residents reported that other birds.

  12. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    Yomi

    2010-08-18

    Aug 18, 2010 ... transmission lines on ornamental plant growth. Zeki Demir ... The effects of proximity to power-line on specific leaf area and seedling dbh were tested .... during vegetation season is about 72% and common wind blow.

  13. Natural radiation focused by power lines: new evidence

    Energy Technology Data Exchange (ETDEWEB)

    Hopwood, Anthony

    1992-11-01

    Scientists searching for a mechanism to explain increases in the incidence of cancer among those living in close proximity to power lines could have been looking in the wrong place. New evidence suggests that instead of trying to find an as yet unproven cellular reaction to the presence of the power-line's magnetic fields, researchers should investigate power lines as concentrators of potentially damaging natural sky radiation. If accepted, a clear link between a known biological cell damage mechanism and power lines will have been established, triggering a reassessment of the independent studies recording statistical increases in cancer incidence around power lines. The evidence stems from recordings showing concentrations of background solar radiation under power lines - a direction of enquiry prompted by a chance observation made during a British Astronomical Association experiment. (Author).

  14. On-line calculation of 3-D power distribution

    International Nuclear Information System (INIS)

    Park, Y. H.; In, W. K.; Park, J. R.; Lee, C. C.; Auh, G. S.

    1996-01-01

    The 3-D power distribution synthesis scheme was implemented in Totally Integrated Core Operation Monitoring System (TICOMS), which is under development as the next generation core monitoring system. The on-line 3-D core power distribution obtained from the measured fixed incore detector readings is used to construct the hot pin power as well as the core average axial power distribution. The core average axial power distribution and the hot pin power of TICOMS were compared with those of the current digital on-line core monitoring system, COLSS, which construct the core average axial power distribution and the pseudo hot pin power. The comparison shows that TICOMS results in the slightly more accurate core average axial power distribution and the less conservative hot pin power. Therefore, these results increased the core operating margins. In addition, the on-line 3-D power distribution is expected to be very useful for the core operation in the future

  15. Power Line Communication (PLC) in Space - Current Status and Outlook

    Science.gov (United States)

    Wolf, J.

    2012-05-01

    The Power Line Communication (PLC) technology as known from various terrestrial applications, e.g. in building automation, in the automotive sector and on aircraft, appears to be a promising technology for the use on spacecraft. Starting from a critical overview on existing terrestrial PLC applications with their pros and cons, the paper gives a motivation for the introduction of the PLC technology on spacecraft, discusses the potential areas where it can be applied and is highlighting the potential problem areas. A short overview of on-going ESA PLC activities is provided and an outlook is given.

  16. 3D Power Line Extraction from Multiple Aerial Images

    Directory of Open Access Journals (Sweden)

    Jaehong Oh

    2017-09-01

    Full Text Available Power lines are cables that carry electrical power from a power plant to an electrical substation. They must be connected between the tower structures in such a way that ensures minimum tension and sufficient clearance from the ground. Power lines can stretch and sag with the changing weather, eventually exceeding the planned tolerances. The excessive sags can then cause serious accidents, while hindering the durability of the power lines. We used photogrammetric techniques with a low-cost drone to achieve efficient 3D mapping of power lines that are often difficult to approach. Unlike the conventional image-to-object space approach, we used the object-to-image space approach using cubic grid points. We processed four strips of aerial images to automatically extract the power line points in the object space. Experimental results showed that the approach could successfully extract the positions of the power line points for power line generation and sag measurement with the elevation accuracy of a few centimeters.

  17. Relationship of the Functional Movement Screen In-Line Lunge to Power, Speed, and Balance Measures

    OpenAIRE

    Hartigan, Erin H.; Lawrence, Michael; Bisson, Brian M.; Torgerson, Erik; Knight, Ryan C.

    2014-01-01

    Background: The in-line lunge of the Functional Movement Screen (FMS) evaluates lateral stability, balance, and movement asymmetries. Athletes who score poorly on the in-line lunge should avoid activities requiring power or speed until scores are improved, yet relationships between the in-line lunge scores and other measures of balance, power, and speed are unknown. Hypothesis: (1) Lunge scores will correlate with center of pressure (COP), maximum jump height (MJH), and 36.6-meter sprint time...

  18. Integrated Off-Line Power Converter

    DEFF Research Database (Denmark)

    Fan, Lin

    The miniaturization trend of industrial and consumer electronics continuously drives the demand of reductions in size, weight, and cost of power supplies. The examples of such applications considered in this research are light-emitting diode (LED) drivers for intelligent lighting systems and inte......The miniaturization trend of industrial and consumer electronics continuously drives the demand of reductions in size, weight, and cost of power supplies. The examples of such applications considered in this research are light-emitting diode (LED) drivers for intelligent lighting systems......-resistances) of these devices are jointly determined by the device, layout, package, and PCB parasitic properties. The research highly contributes to the development towards Power Supply on Chip (PwrSoC) regardless of topologies and switching technologies. First, parasitic capacitances of power semiconductors are a part...

  19. 76 FR 71892 - Broadband Over Power Lines

    Science.gov (United States)

    2011-11-21

    ... interference distance to fixed stations would be 62 meters at 2-8 MHz and 400 meters at 8-30 MHz in areas where... line 230 meters from the coupler. ii. The proper distance extrapolation factor for assumed signal decay... median values of man-made noise at 30-meters distance. Extrapolating this to a mobile antenna closer to...

  20. Matching problems in pulse power radial transmission lines

    International Nuclear Information System (INIS)

    Mittag, K.; Brandelik, A.

    1984-12-01

    In this report we study the power transfer from a generator along a coaxial transmission line followed by a radial transmission line into a load, which in our application is a pseudo-spark plasma of about one millimeter diameter and about 15 cm in length. First the theoretical background based on transmission line theory is described. Then numerical results are presented. The main conclusion is that when matching the pulse power generator to the pseudo-spark plasma, the effect of the impedance transformation caused by the radial transmission line has to be taken into account. The conditions to obtain an optimal match are described. (orig.) [de

  1. A congestion line flow control in deregulated power system

    Directory of Open Access Journals (Sweden)

    Venkatarajan Shanmuga Sundaram

    2011-01-01

    Full Text Available Under open access, market-driven transactions have become the new independent decision variables defining the behavior of the power system. The possibility of transmission lines getting over-loaded is relatively more under deregulated operation because different parts of the system are owned by separate companies and in part operated under varying service charges. This paper discusses a two-tier algorithm for correcting the lone overloads in conjunction with the conventional power-flow methods. The method uses line flow sensitivities, which are computed by the East Decoupled Power-flow algorithm and can be adapted for on-line implementation.

  2. Discretionary Power on the Front-line

    DEFF Research Database (Denmark)

    Sanden, Guro Refsum; Lønsmann, Dorte

    This article investigates the communication practices used by front-line employees to cross language boundaries in the context of English language policies implemented by the management of three multinational corporations (MNCs) headquartered in Scandinavia. Based on an analysis of interview...... and document data, our findings show that employees face a number of different language boundaries in their everyday work, and that ad hoc and informal solutions in many cases are vital for successful cross-language communication. We introduce the concept of ‘discretionary power’ to explain how and why front...

  3. National Maglev initiative: California line electric utility power system requirements

    Science.gov (United States)

    Save, Phil

    1994-01-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  4. A Simulator of Periodically Switching Channels for Power Line Communications

    Science.gov (United States)

    Hayasaki, Taro; Umehara, Daisuke; Denno, Satoshi; Morikura, Masahiro

    An indoor power line is one of the most attractive media for in-home networks. However, there are many technical problems for achieving in-home power line communication (PLC) with high rate and high reliability. One of such problem is the degradation in the performance of the in-home PLC caused by periodically time-varying channel responses, particularly when connecting the switching power supply equipment. We present a measurement method for power line channel responses and reveal the switching of the channel responses synchronized with power-frequency voltage when connecting switching power supply equipment in sending or receiving outlets. In this paper, we term them periodically switching channel responses. The performance of PLC adapters is seriously affected by the periodically switching channel responses. Therefore, we provide a modeling of the periodically switching channel responses by using finite impulse response (FIR) filters with a shared channel memory and construct a simulator for in-home power line channels including the periodically switching channel responses in order to evaluate the various communication systems through the power line. We present the validity of the proposed simulator through the performance evaluation of OFDM/64QAM over periodically switching channels with additive white Gaussian noise. Furthermore, we evaluate the influence of the periodically switching channel responses on the communication quality of a time-invariant modulation scheme by using the proposed simulator.

  5. Mini-Uav LIDAR for Power Line Inspection

    Science.gov (United States)

    Teng, G. E.; Zhou, M.; Li, C. R.; Wu, H. H.; Li, W.; Meng, F. R.; Zhou, C. C.; Ma, L.

    2017-09-01

    Light detection and ranging (LIDAR) system based on unmanned aerial vehicles (UAVs) recently are in rapid advancement, meanwhile portable and flexible mini-UAV-borne laser scanners have been a hot research field, especially for the complex terrain survey in the mountains and other areas. This study proposes a power line inspection system solution based on mini-UAV-borne LIDAR system-AOEagle, developed by Academy of Opto-Electronics, Chinese Academy of Sciences, which mounted on a Multi-rotor unmanned aerial vehicle for complex terrain survey according to real test. Furthermore, the point cloud data was explored to validate its applicability for power line inspection, in terms of corridor and line laser point clouds; deformation detection of power towers, etc. The feasibility and advantages of AOEagle have been demonstrated by the promising results based on the real-measured data in the field of power line inspection.

  6. Focusing of cosmic radiation near power lines. A theoretical approach

    International Nuclear Information System (INIS)

    Skedsmo, A.; Vistnes, A.I.

    1997-02-01

    The purpose of this work was to determine if, and to what extent, cosmic radiation can be focused by power lines. As an alternative to experimental measurements, a computer program was developed for simulation of particle trajectories. Starting from given initial values, the cosmic particles trajectories through the electromagnetic field surrounding power lines were simulated. Particular efforts have been made to choose initial values which represent the actual physical condition of the cosmic radiation at ground level. The results show an average decrease in the particle flux density in an area below a power line and a corresponding increased flux between 12 m and 45 m on either side of the centre of the power line. The average shift in flux density is, however, extremely small (less than 0.1%) and probably not measurable with existing detector technology. 11 refs., 4 figs., 2 tabs

  7. Optimization design of toroidal core for magnetic energy harvesting near power line by considering saturation effect

    Science.gov (United States)

    Park, Bumjin; Kim, Dongwook; Park, Jaehyoung; Kim, Kibeom; Koo, Jay; Park, HyunHo; Ahn, Seungyoung

    2018-05-01

    Recently, magnetic energy harvesting technologies have been studied actively for self-sustainable operation of applications around power line. However, magnetic energy harvesting around power lines has the problem of magnetic saturation, which can cause power performance degradation of the harvester. In this paper, optimal design of a toroidal core for magnetic energy harvesters has been proposed with consideration of magnetic saturation near power lines. Using Permeability-H curve and Ampere's circuital law, the optimum dimensional parameters needed to generate induced voltage were analyzed via calculation and simulation. To reflect a real environment, we consider the nonlinear characteristic of the magnetic core material and supply current through a 3-phase distribution panel used in the industry. The effectiveness of the proposed design methodology is verified by experiments in a power distribution panel and takes 60.9 V from power line current of 60 A at 60 Hz.

  8. Power system damping - Structural aspects of controlling active power

    Energy Technology Data Exchange (ETDEWEB)

    Samuelsson, O.

    1997-04-01

    Environmental and economical aspects make it difficult to build new power lines and to reinforce existing ones. The continued growth in demand for electric power must therefore to a great extent be met by increased loading of available lines. A consequence is that power system damping is reduced, leading to a risk of poorly damped power oscillations between the generators. This thesis proposes the use of controlled active loads to increase damping of such electro-mechanical oscillations. The focus is on structural aspects of controller interaction and of sensor and actuator placement. On-off control based on machine frequency in a single machine infinite bus system is analysed using energy function analysis and phase plane plots. An on-off controller with estimated machine frequency as input has been implemented. At a field test it damped oscillations of a 0.9 MW hydro power generator by controlling a 20kW load. The linear analysis uses two power system models with three and twenty-three machines respectively. Each damper has active power as output and local bus frequency or machine frequency as input. The power system simulator EUROSTAG is used both for generation of the linearized models and for time simulations. Measures of active power mode controllability and phase angle mode observability are obtained from the eigenvectors of the differential-algebraic models. The geographical variation in the network of these quantities is illustrated using the resemblance to bending modes of flexible mechanical structures. Eigenvalue sensitivities are used to determine suitable damper locations. A spring-mass equivalent to an inter-area mode provides analytical expressions, that together with the concept of impedance matching explain the structural behaviour of the power systems. For large gains this is investigated using root locus plots. 64 refs, 99 figs, 20 tabs

  9. Power-line Interference Removal from ECG in Case of Power-line Frequency Variations

    Directory of Open Access Journals (Sweden)

    Todor Stoyanov

    2008-10-01

    Full Text Available The original version of the most successful approach for power-line (PL interference removal from ECG, called subtraction procedure, is based on linear segment detection in the signal and hardware synchronised analogue-to-digital conversion to cope with the PL frequency variations. However, this is not feasible for battery supplied devices and some computer-aided ECG systems. Recent improvements of the procedure apply software measurement of the frequency variations that allow a re-sampling of the contaminated signal with the rated PL frequency followed by interference removal and back re-sampling for restoration of the original time intervals. This study deals with a more accurate software frequency measurement and introduces a notch filtration as alternative to the procedure when no linear segments are encountered for long time, e.g. in cases of ventricular fibrillation or tachycardia. The result obtained with large PL frequency variations demonstrate very small errors, usually in the range of ± 20 μV for the subtraction procedure and ± 60 μV for the notch filtration, the last values strongly depending on the frequency contents of the QRS complexes.

  10. DSP Control of Line Hybrid Active Filter

    DEFF Research Database (Denmark)

    Dan, Stan George; Benjamin, Doniga Daniel; Magureanu, R.

    2005-01-01

    Active Power Filters have been intensively explored in the past decade. Hybrid active filters inherit the efficiency of passive filters and the improved performance of active filters, and thus constitute a viable improved approach for harmonic compensation. In this paper a parallel hybrid filter...... is studied for current harmonic compensation. The hybrid filter is formed by a single tuned Le filter and a small-rated power active filter, which are directly connected in series without any matching transformer. Thus the required rating of the active filter is much smaller than a conventional standalone...... active filter. Simulation and experimental results obtained in laboratory confirmed the validity and effectiveness of the control....

  11. Harmonizing power cables and power lines. Harmonisierung der Starkstromkabel und -leitungen

    Energy Technology Data Exchange (ETDEWEB)

    Heinhold, L [Siemens A.G., Erlangen (Germany, F.R.); Retzlaff, E; Warner, A [Verband Deutscher Elektrotechniker (VDE) e.V., Frankfurt am Main (Germany, F.R.)

    1976-01-01

    The article gives a summarizing view of the present level of harmonization in the field of power cables and lines. Special attention is paid to problems referring to using harmonized designs for flexible lines and using lines for solid layout with PVC and rubber insulation in the German standards DIN 57281/VDE 0281 and DIN 57282/VDE 0282 and problems of taking the types used until today out of use. A general view of the power lines fully harmonized is given and a harmonization-labelling (common labelling) for cables and lines is described.

  12. Series active power filter in power conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Turunen, J.

    2009-07-01

    Power quality has become an important issue nowadays for several reasons, e.g. modern society's growing dependence on electricity and the fact that poor power quality may generate significant economic losses in few moments. Probable power quality problems are, e.g. harmonics, flicker, voltage dips and supply interruptions. The power quality may be improved by using filters and compensators.The purpose of this thesis is to research the operation of the series active power filter (SAPF) in power conditioning. Therefore, this thesis presents a comparison of three series hybrid active power filters (SHAPFs) in current harmonics filtering. In addition to this, it is shown how the voltage dip compensation performance of the SAPF is improved in a unified power quality conditioner (UPQC) application.The three SHAPFs included in the comparison are series connected topology (SCT), filter connected topology (FCT) and electrically tuned LC shunt circuit (ETLC). The operating principle of these filters is to direct the harmonic currents produced by the load to flow in the LC shunt circuits instead of the supply. In the case of the SCT this phenomenon is boosted by applying so-called active resistance in the supply branch using the SAPF. In the case of the FCT a similar action is achieved by applying the compensation voltage in series with the LC shunt circuits using the SAPF. In the case of the ETLC the performance of the LC shunt circuit is enhanced by applying so-called active inductances in series with the LC shunt circuit using the SAPF. The SHAPFs are compared by searching for their best current filtering performance using various main circuit and control system configurations and loads. The operation of the SHAPFs is first analysed mathematically. After this, the current filtering performance of the SHAPFs is inspected using simulations and experimental tests. The experimental tests are carried out using SHAPF prototypes. As a result, it is shown that the current

  13. Comparison of electric field exposure measurement methods under power lines

    International Nuclear Information System (INIS)

    Korpinen, L.; Kuisti, H.; Tarao, H.; Paeaekkoenen, R.; Elovaara, J.

    2014-01-01

    The object of the study was to investigate extremely low frequency (ELF) electric field exposure measurement methods under power lines. The authors compared two different methods under power lines: in Method A, the sensor was placed on a tripod; and Method B required the measurer to hold the meter horizontally so that the distance from him/her was at least 1.5 m. The study includes 20 measurements in three places under 400 kV power lines. The authors used two commercial three-axis meters, EFA-3 and EFA-300. In statistical analyses, they did not find significant differences between Methods A and B. However, in the future, it is important to take into account that measurement methods can, in some cases, influence ELF electric field measurement results, and it is important to report the methods used so that it is possible to repeat the measurements. (authors)

  14. On-line adaptive line frequency noise cancellation from a nuclear power measuring channel

    Directory of Open Access Journals (Sweden)

    Qadir Javed

    2011-01-01

    Full Text Available On-line software for adaptively canceling 50 Hz line frequency noise has been designed and tested at Pakistan Research Reactor 1. Line frequency noise causes much problem in weak signals acquisition. Sometimes this noise is so dominant that original signal is totally corrupted. Although notch filter can be used for eliminating this noise, but if signal of interest is in close vicinity of 50 Hz, then original signal is also attenuated and hence overall performance is degraded. Adaptive noise removal is a technique which could be employed for removing line frequency without degrading the desired signal. In this paper line frequency noise has been eliminated on-line from a nuclear power measuring channel. The adaptive LMS algorithm has been used to cancel 50 Hz noise. The algorithm has been implemented in labVIEW with NI 6024 data acquisition card. The quality of the acquired signal has been improved much as can be seen in experimental results.

  15. Environmental impact of the aerial power transmission lines

    International Nuclear Information System (INIS)

    Cristescu, D.; Rusan, R.

    1993-01-01

    In the last 10-12 years the existence of the high voltage lines existence within populated areas has been more and more contested. The paper tries to complete a blank in the Romanian technical literature by introducing the concept of 'line corridor' which is different from the occupied geometric area and from 'the line disturbed corridor'. The concept is meant to specify the area where the high frequency and 50 Hz electromagnetic pollution exceeds some given limits. The impact of the power transmission lines on the human body, due to the effects of the electric and magnetic fields, is considered. Also, the aspects concerning the visual impact, the acoustic and radio noise and the area expensing by the high voltage lines, are considered. International standards and regulations regarding the limitations of this effects are presented. (author)

  16. Fast wave power flow along SOL field lines in NSTX

    Science.gov (United States)

    Perkins, R. J.; Bell, R. E.; Diallo, A.; Gerhardt, S.; Hosea, J. C.; Jaworski, M. A.; Leblanc, B. P.; Kramer, G. J.; Phillips, C. K.; Roquemore, L.; Taylor, G.; Wilson, J. R.; Ahn, J.-W.; Gray, T. K.; Green, D. L.; McLean, A.; Maingi, R.; Ryan, P. M.; Jaeger, E. F.; Sabbagh, S.

    2012-10-01

    On NSTX, a major loss of high-harmonic fast wave (HHFW) power can occur along open field lines passing in front of the antenna over the width of the scrape-off layer (SOL). Up to 60% of the RF power can be lost and at least partially deposited in bright spirals on the divertor floor and ceiling [1,2]. The flow of HHFW power from the antenna region to the divertor is mostly aligned along the SOL magnetic field [3], which explains the pattern of heat deposition as measured with infrared (IR) cameras. By tracing field lines from the divertor back to the midplane, the IR data can be used to estimate the profile of HHFW power coupled to SOL field lines. We hypothesize that surface waves are being excited in the SOL, and these results should benchmark advanced simulations of the RF power deposition in the SOL (e.g., [4]). Minimizing this loss is critical optimal high-power long-pulse ICRF heating on ITER while guarding against excessive divertor erosion.[4pt] [1] J.C. Hosea et al., AIP Conf Proceedings 1187 (2009) 105. [0pt] [2] G. Taylor et al., Phys. Plasmas 17 (2010) 056114. [0pt] [3] R.J. Perkins et al., to appear in Phys. Rev. Lett. [0pt] [4] D.L. Green et al., Phys. Rev. Lett. 107 (2011) 145001.

  17. Proximity to overhead power lines and childhood leukaemia

    DEFF Research Database (Denmark)

    Amoon, Aryana T; Crespi, Catherine M; Ahlbom, Anders

    2018-01-01

    BACKGROUND: Although studies have consistently found an association between childhood leukaemia risk and magnetic fields, the associations between childhood leukaemia and distance to overhead power lines have been inconsistent. We pooled data from multiple studies to assess the association with d...

  18. Quality electricity lines of external power systems electric traction DC

    Directory of Open Access Journals (Sweden)

    A.V. Petrov

    2012-08-01

    Full Text Available The results of studies that compare and analyze the numerical values of some key indicators quality electricity in the lines of the external power supply system the electric traction DC. As a supplement are additional and fundamental values of energy losses in them.

  19. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    The proximity effects of high voltage electric power transmission lines on Leyland Cypress (xCupressocyparis leylandii (Dallim. and A.B. Jacks.) Dallim) and Japanese Privet (Ligustrum japonicum Thunb.) growth were examined in a private nursery located in Sakarya, Turkey. Five transect were randomly chosen in both ...

  20. Designing concept on lightning protection of overhead power distribution line

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Shigeru [Central Research Institute of Electric Power Industry, Kanagawa-ken (Japan)], E-mail: yokoyama@criepi.denken.or.jp

    2007-07-01

    The principle is shown for lightning protection of power distribution lines taking the effects of surge arresters, overhead ground wires and their combined use into consideration. Moreover an outline of a rational design method targeting direct lightning hits, induced over voltages and back flow currents from high structures. (author)

  1. Stacked dipole line source excitation of active nano-particles

    DEFF Research Database (Denmark)

    Arslanagic, Samel

    This work investigates electromagnetic properties of cylindrical active coated nano-particles excited by a stac- ked electric dipole line source. The nano-particles consist of a silica nano-core, layered by silver, gold, or copper nano-shell. Attention is devoted to the influence of the source...... location and dipole orientation, the gain constant, and the nano-particle material composition on the electromagnetic field distributions and radiated powers. The results are contrasted to those for the magnetic line source illumination of the nano-particles....

  2. Flat tie-line power scheduling control of grid-connected hybrid microgrids

    DEFF Research Database (Denmark)

    Xiao, Zhao xia; Guerrero, Josep M.; Shuang, Jia

    2018-01-01

    In future active distribution networks (ADNs), microgrids (MGs) may have the possibility to control the power dispatched to the ADN by coordinating the output power of their multiple renewable generation units and energy storage units (ESUs). In this way, each MG may support the active distribution....... Also, a method to calculate the tie-line power flow to be exchanged between the MG and the ADN is explored, and a power ramp rate is given between different dispatch intervals. Finally, a simulation model of the hybrid MG is built and tested. Simulation results show that the proposed hierarchical...

  3. On-line Monitoring System for Power Transformers

    Directory of Open Access Journals (Sweden)

    Alexandru HOTEA

    2016-12-01

    Full Text Available Power transformers are the most important and expensive equipment from the electricity transmission system, so it is very important to know the real state of health of such equipment in every moment. De-energizing the power transformer accidentally due to internal defects can generate high costs. Annual maintenance proved to be ineffective in many cases to determine the internal condition of the equipment degradation due to faults rapidly evolving. An On-line Monitoring System for Power Transformers help real-time condition assessment and to detect errors early enough to take action to eliminate or minimize them. After abnormality detected, it is still important to perform full diagnostic tests to determine the exact condition of the equipment. On-line monitoring systems can help increase the level of availability and reliability of power transformers and lower costs of accidental interruption. This paper presents cases studies on several power transformers equipped with on-line monitoring systems from Transelectrica substation.

  4. Limiting electric fields of HVDC overhead power lines.

    Science.gov (United States)

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths.

  5. Monitoring Biological Activity at Geothermal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Peter Pryfogle

    2005-09-01

    The economic impact of microbial growth in geothermal power plants has been estimated to be as high as $500,000 annually for a 100 MWe plant. Many methods are available to monitor biological activity at these facilities; however, very few plants have any on-line monitoring program in place. Metal coupon, selective culturing (MPN), total organic carbon (TOC), adenosine triphosphate (ATP), respirometry, phospholipid fatty acid (PLFA), and denaturing gradient gel electrophoresis (DGGE) characterizations have been conducted using water samples collected from geothermal plants located in California and Utah. In addition, the on-line performance of a commercial electrochemical monitor, the BIoGEORGE?, has been evaluated during extended deployments at geothermal facilities. This report provides a review of these techniques, presents data on their application from laboratory and field studies, and discusses their value in characterizing and monitoring biological activities at geothermal power plants.

  6. Power Lines and Crops Can Be Good Neighbors

    Energy Technology Data Exchange (ETDEWEB)

    None

    2010-08-01

    Two of the Pacific Northwest’s greatest economic assets are its wealth of agriculture and its clean and reliable electricity fueled largely by hydropower. Sometimes the two intersect. Transmission lines carrying electricity to the region’s farms, businesses and homes must, of necessity, span large areas where people grow crops and orchards. To ensure a safe and reliable flow of electricity across these expanses, trees and other vegetation must be managed to certain standards. At the same time, the Bonneville Power Administration — which owns and operates three-quarters of the region’s high-voltage transmission — recognizes the importance of our region’s agricultural bounty. We are committed to working with individuals and agricultural communities to facilitate ongoing land-use activities in transmission rights-of-way as long as those uses are compatible with transmission safety and reliability standards. Our goal with vegetation management is to keep you and your property safe while protecting the reliability of our region’s electricity system. By working together, BPA and landowners can protect the system and public safety.

  7. ENVIRONMENTAL POLLUTION BY MAGNETIC FIELD AROUND POWER LINES

    Directory of Open Access Journals (Sweden)

    Vesna Ranković

    2009-09-01

    Full Text Available According to the contemporary epidemiological researches, there are some indications that extremely low frequency electromagnetic fields harm human health which has been proved through numerous scientific studies published in recent years. Today, most countries use the ICNIRP guidelines and Council Recommendation as the scientific basis for their recommended levels of exposure. Magnetic fields from high voltage transmission power lines have been discussed in this paper. The field profiles and their contribution to environmental pollution are studied. The obtained results are found to be useful for discussing the comparison of the field densities on the human body at the ground level under or near the lines.

  8. Effects of Power Lines on Area Use and Behaviour of Semi-Domestic Reindeer in Enclosures

    International Nuclear Information System (INIS)

    Flydal, K.; Reimers, E.; Johansen, F.; Colman, J.E.; Korslund, L.; Colman, J.E.

    2009-01-01

    We conducted large-scale, replicated experiments to test the effects of two parallel power lines on area use, behaviour, and activity of semidomestic reindeer in enclosures. Yearling female reindeer were released into four 50 x 400 m enclosures; two treatment enclosures with power lines and two control enclosures. Reindeer from two herds, one from Kautokeino (domestic tame) and one from Vaga, (domestic wild) were tested separately and compared. Individual location within the enclosures was not affected by the power lines. Effects on restless behaviour were ambiguous, with slightly more restless behaviour in the treatment enclosures for the domestic tame reindeer, while the domestic wild reindeer maintained a stable level in the treatment enclosures, increasing with time in the control enclosures. Activity changes were slightly more common among animals within treatment enclosures for both herds, with no indication of habituation during the experiment. The domestic wild reindeer had more than three times the amount of restless behaviour than the domestic tame reindeer. Our study indicates that for reindeer in enclosures, the disturbance from a power line construction is negligible. This suggests that power lines are a minor disturbing factor compared to human handling when using fenced in areas like grazing gardens in reindeer husbandry.

  9. Early environmental planning: A process for power line corridor selection

    International Nuclear Information System (INIS)

    Haagenstad, T.; Bare, C.M.

    1998-01-01

    Los Alamos National Laboratory (LANL) conducted an environmental planning study in the fall of 1997 to help determine the best alternative for upgrading the Laboratory's electrical power system. Alternatives considered included an on-site power generation facility and two corridors for a 10-mile-long 115-kV power line. This planning process was conducted prior to the formal National Environmental Policy Act (NEPA) review. The goals were to help select the best proposed action, to recommend modifications and mitigation measures for each alternative for a more environmentally sound project, and to avoid potential delays once the formal Department of Energy review process began. Significant constraints existed from a planning perspective, including operational issues such as existing outdoor high explosives testing areas, as well as environmental issues including threatened and endangered species habitats, multiple archeological sites, contaminated areas, and aesthetics. The study had to be completed within 45 days to meet project schedule needs. The process resulted in a number of important recommendations. While the construction and operation of the on-site power generation facility could have minimal environmental impacts, the need for a new air quality permit would create severe cost and schedule constraints for the project. From an environmental perspective, construction and operation of a power line within either corridor was concluded to be a viable alternative. However, impacts with either corridor would have to be reduced through specific recommended alignment modifications and mitigation measures

  10. Induced voltages in metallic pipelines near power transmission lines

    International Nuclear Information System (INIS)

    Grcev, Leonid; Jankov, Voislav; Filiposki, Velimir

    2002-01-01

    With the continuous development of the electric power system and the pipeline networks used to convey oil or natural gas, cases of close proximity of high voltage structures and metallic pipelines become more and more frequent. Accordingly there is a growing concern about possible hazards resulting from voltages induced in the metallic pipelines by magnetic coupling with nearby power transmission lines. This paper presents a methodology for computation of the induced voltages in buried isolated metallic pipelines. A practical example of computation is also presented. (Author)

  11. Power lines Phoenix and the making of the modern southwest

    CERN Document Server

    Needham, Andrew

    2014-01-01

    In 1940, Phoenix was a small, agricultural city of sixty-five thousand, and the Navajo Reservation was an open landscape of scattered sheepherders. Forty years later, Phoenix had blossomed into a metropolis of 1.5 million people and the territory of the Navajo Nation was home to two of the largest strip mines in the world. Five coal-burning power plants surrounded the reservation, generating electricity for export to Phoenix, Los Angeles, and other cities. Exploring the postwar developments of these two very different landscapes, Power Lines tells the story of the far-reaching environmental a

  12. On-line Dynamic Security Assessment in Power Systems

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel

    and solar radiation. Moreover, ongoing research suggests that demand response will be introduced to maintain power balance between generation and consumption at all times. Due to these changes the operating point of the power system will be less predictable and today’s stability and security assessment...... for early prediction of critical voltage sags is described. The method’s performance is compared to other prediction approaches. The results show that the proposed method succeeds in early, accurately and consistently predicting critically low voltage sags. An efficient on-line DSA not only identifies...

  13. A field experiment on power line stabilization by SMES system

    International Nuclear Information System (INIS)

    Irie, F.; Takeo, M.; Sato, S.; Katahira, O.; Fukui, F.; Takamatsu, M.

    1992-01-01

    In this paper field experiments on stabilization of a hydro power plant by a SMES system are reported, where a generator having a rating of 60 kW at 3.3kV is connected to a 6.6kV power distribution line. The SMES system is composed of two 30kVA GTO convertors and a superconducting magnet system with an energy of 30kJ at 100A. Experiments of stabilization for the generator fluctuation caused by a sudden insertion of inductors in the line are successfully performed for some control modes. The value of the SMES system to compensate for a short period voltage dip is also confirmed

  14. LDPC Code Design for Nonuniform Power-Line Channels

    Directory of Open Access Journals (Sweden)

    Sanaei Ali

    2007-01-01

    Full Text Available We investigate low-density parity-check code design for discrete multitone channels over power lines. Discrete multitone channels are well modeled as nonuniform channels, that is, different bits experience various channel parameters. We propose a coding system for discrete multitone channels that allows for using a single code over a nonuniform channel. The number of code parameters for the proposed system is much greater than the number of code parameters in conventional channel. Therefore, search-based optimization methods are impractical. We first formulate the problem of optimizing the rate of an irregular low-density parity-check code, with guaranteed convergence over a general nonuniform channel, as an iterative linear programming which is significantly more efficient than search-based methods. Then we use this technique for a typical power-line channel. The methodology of this paper is directly applicable to all decoding algorithms for which a density evolution analysis is possible.

  15. Improved anchorage of steel linings at WWER nuclear power plants

    International Nuclear Information System (INIS)

    Bouda, M.; Cepicky, J.

    1987-01-01

    Three variants were tested of anchoring the steel lining of special structures of nuclear power plants with WWER reactors, such as the containment, viz.: point anchorage with pins according to a Czechoslovak design, and two methods of linear anchorage according to a Soviet design and a design by the Institute for Industrial Construction of the GDR. Graphically shown are some results of the tests of the point anchorage with pins that showed the reliability of the method with respect to deformation and strain of the lining and of the anchoring elements at a lining temperature of up to 300 degC, which significantly exceeded the design-basis accident temperature of 150 degC. The advantages of the variant include a lower content of labour and an increased quality of welding jobs thanks to the application of the Nelson semi-automatic welding technique. (Z.M.). 10 figs., 7 refs

  16. Development of Live-working Robot for Power Transmission Lines

    Science.gov (United States)

    Yan, Yu; Liu, Xiaqing; Ren, Chengxian; Li, Jinliang; Li, Hui

    2017-07-01

    Dream-I, the first reconfigurable live-working robot for power transmission lines successfully developed in China, has the functions of autonomous walking on lines and accurately positioning. This paper firstly described operation task and object of the robot; then designed a general platform, an insulator replacement end and a drainage plate bolt fastening end of the robot, presented a control system of the robot, and performed simulation analysis on operation plan of the robot; and finally completed electrical field withstand voltage tests in a high voltage hall as well as online test and trial on actual lines. Experimental results show that by replacing ends of manipulators, the robot can fulfill operation tasks of live replacement of suspension insulators and live drainage plate bolt fastening.

  17. Environmental impacts of power plants and transmission lines in power system planning

    International Nuclear Information System (INIS)

    Miracapillo, C.; Moreschini, G.; Rome Univ. 'La Sapienza'

    1992-01-01

    This paper deals with a criterion to assess the environmental impacts of power plants and transmission lines in power system planning. First, the effects of hydro-plants, thermal plants and transmission lines are reviewed. Then, a number of methods for the evaluation of the environmental impacts of civil and industrial plants are described. A new criterion is proposed to introduce the evaluation of the environmental impact and related costs into methods for power system planning. Finally, the criterion is applied to a simple case

  18. Do power lines and protected areas present a catch-22 situation for Cape vultures (Gyps coprotheres)?

    Science.gov (United States)

    Phipps, W Louis; Wolter, Kerri; Michael, Michael D; MacTavish, Lynne M; Yarnell, Richard W

    2013-01-01

    Cape vulture Gyps coprotheres populations have declined across their range due to multiple anthropogenic threats. Their susceptibility to fatal collisions with the expanding power line network and the prevalence of carcasses contaminated with illegal poisons and other threats outside protected areas are thought to be the primary drivers of declines in southern Africa. We used GPS-GSM units to track the movements and delineate the home ranges of five adult (mean ±SD minimum convex polygon area = 121,655±90,845 km(2)) and four immature (mean ±SD minimum convex polygon area = 492,300±259,427 km(2)) Cape vultures to investigate the influence of power lines and their use of protected areas. The vultures travelled more than 1,000 km from the capture site and collectively entered five different countries in southern Africa. Their movement patterns and core foraging ranges were closely associated with the spatial distribution of transmission power lines and we present evidence that the construction of power lines has allowed the species to extend its range to areas previously devoid of suitable perches. The distribution of locations of known Cape vulture mortalities caused by interactions with power lines corresponded to the core ranges of the tracked vultures. Although some of the vultures regularly roosted at breeding colonies located inside protected areas the majority of foraging activity took place on unprotected farmland. Their ability to travel vast distances very quickly and the high proportion of time they spend in the vicinity of power lines and outside protected areas make Cape vultures especially vulnerable to negative interactions with the expanding power line network and the full range of threats across the region. Co-ordinated cross-border conservation strategies beyond the protected area network will therefore be necessary to ensure the future survival of threatened vultures in Africa.

  19. Advanced power cycling test for power module with on-line on-state VCE measurement

    DEFF Research Database (Denmark)

    Choi, Ui-min; Trintis, Ionut; Blaabjerg, Frede

    2015-01-01

    module. The proposed concept can perform various stress conditions which is valid in a real mission profile and it is using a real power converter application with small loss. The concept of the proposed test setup is first presented. Then, the on-line on-state collector-emitter voltage VCE measurement......Recent research has made an effort to improve the reliability of power electronic systems to comply with more stringent constraints on cost, safety, predicted lifetime and availability in many applications. For this, studies about failure mechanisms of power electronic components and lifetime...... estimation of power semiconductor devices and capacitors have been done. Accelerated power cycling test is one of the common tests to assess the power device module and develop the lifetime model considering the physics of failure. In this paper, a new advanced power cycling test setup is proposed for power...

  20. Visual impact of overhead power transmission lines and dielectric and corona effects constraints on insulation coordination

    International Nuclear Information System (INIS)

    Deponti, F.; Fini, G.P.; Porrino, A.; Rosa, F.

    1992-06-01

    In assessing overhead power transmission line design and planning criteria for the optimization of visual impact, safety and the reduction of electro magnetic disturbance effects, this paper reviews the research findings of ENEL, the Italian Electricity Board. The on-going research activities involve theoretical calculations and laboratory performance tests to determine the best compact configurations for 380 kV lines. The parameters under examination include: insulator spacing, sizing and salt fog resistivity; allowable overvoltages; maximum line length; behaviour in lightning conditions; radio and acoustics disturbances

  1. Modeling particle emission and power flow in pulsed-power driven, nonuniform transmission lines

    Directory of Open Access Journals (Sweden)

    Nichelle Bruner

    2008-04-01

    Full Text Available Pulsed-power driven x-ray radiographic systems are being developed to operate at higher power in an effort to increase source brightness and penetration power. Essential to the design of these systems is a thorough understanding of electron power flow in the transmission line that couples the pulsed-power driver to the load. In this paper, analytic theory and fully relativistic particle-in-cell simulations are used to model power flow in several experimental transmission-line geometries fielded on Sandia National Laboratories’ upgraded Radiographic Integrated Test Stand [IEEE Trans. Plasma Sci. 28, 1653 (2000ITPSBD0093-381310.1109/27.901250]. Good agreement with measured electrical currents is demonstrated on a shot-by-shot basis for simulations which include detailed models accounting for space-charge-limited electron emission, surface heating, and stimulated particle emission. Resonant cavity modes related to the transmission-line impedance transitions are also shown to be excited by electron power flow. These modes can drive oscillations in the output power of the system, degrading radiographic resolution.

  2. Assessment of ELF magnetic fields produced by independent power lines

    International Nuclear Information System (INIS)

    Lucca, G.

    2008-01-01

    In this paper, the problem of assessing the ELF (extremely low-frequency) magnetic fields produced, in a certain area characterised by the presence of more than one independent power line, is faced. The use of the incoherent summation of the single contributions, as an advantageous estimator of the total magnetic field, is proposed and justified by means of a heuristic procedure. This kind of approach can be seen as a useful and practical tool to be employed in environmental impact analysis and in assessing long-term human exposure to ELF magnetic fields. (authors)

  3. Trend on High-speed Power Line Communication Technology

    Science.gov (United States)

    Ogawa, Osamu

    High-speed power line communication (PLC) is useful technology to easily build the communication networks, because construction of new infrastructure is not necessary. In Europe and America, PLC has been used for broadband networks since the beginning of 21th century. In Japan, high-speed PLC was deregulated only indoor usage in 2006. Afterward it has been widely used for home area network, LAN in hotels and school buildings and so on. And recently, PLC is greatly concerned as communication technology for smart grid network. In this paper, the author surveys the high-speed PLC technology and its current status.

  4. Contingency management of power system with Interline Power Flow Controller using Real Power Performance Index and Line Stability Index

    Directory of Open Access Journals (Sweden)

    Akanksha Mishra

    2016-03-01

    Full Text Available As a result of privatization of the electrical industry the power transmission lines have to transfer power at their maximum transmission limits because of the competitive scenario of the electrical market. Hence, secured operation of power system has become one of the most important issues of modern era. In this paper, a probability of severity based placement strategy for Interline Power Flow Controller (IPFC has been proposed based on Composite Severity Index (CSI. The composite severity index provides an exact measure of stress in the line in terms of mega watt overloading and voltage instability. IPFC is placed on the line which has the highest probability of severity during the occurrence of different outages. The IPFC has been tuned for a multi-objective function using Differential Evolution (DE and the results have been compared with genetic Algorithm (GA. To verify the proposed method, it has been tested and implemented on IEEE 14 and 57 bus systems.

  5. Magnet power supply and beam line control for a secondary beam line K6

    International Nuclear Information System (INIS)

    Suzuki, Y.; Takasaki, M.; Minakawa, M.; Ishii, H.; Kato, Y.; Ieiri, M.; Tanaka, K.H.; Noumi, H.; Yamanoi, Y.

    1992-01-01

    K6 is a secondary separated-beam line with momentum range up to 2.0 GeV/c in the north experimental hall at the KEK 12 GeV Proton Synchrotron (KEK-PS). On the construction, newly developed magnet power supplies (MPSs), in each of them a microprocessor is embedded, are introduced. The features of the MPS are as follows: 1, The MPS is connected to an upper-level beam line controller (BLC) by GPIB highway for exchanging simple messages. 2, All the operations of the MPS are supervised by the microprocessor, which has its individual parameters and fault messages. It reduces the load of the upper-level controller. 3, The MPS has functions to inspect itself and to report the result. It saves much time and labor of maintenance. (author)

  6. Fast Burst Synchronization for Power Line Communication Systems

    Directory of Open Access Journals (Sweden)

    Lampe Lutz

    2007-01-01

    Full Text Available Fast burst synchronization is an important requirement in asynchronous communication networks, where devices transmit short data packets in an unscheduled fashion. Such a synchronization is typically achieved by means of a preamble sent in front of the data packet. In this paper, we study fast burst synchronization for power line communication (PLC systems operating below 500 kHz and transmitting data rates of up to about 500 kbps as it is typical in various PLC network applications. In particular, we are concerned with the receiver processing of the preamble signal and the actual design of preambles suitable for fast burst synchronization in such PLC systems. Our approach is comprehensive in that it takes into account the most distinctive characteristics of the power line channel, which are multipath propagation, highly varying path loss, and disturbance by impulse noise, as well as important practical constraints, especially the need for spectral shaping of the preamble signal and fast adjustment of the automatic gain control (AGC. In fact, we regard the explicit incorporation of these various requirements into the preamble design as the main contribution of this work. We devise an optimization criterion and a stochastic algorithm to search for suitable preamble sequences. A comprehensive performance comparison of a designed and two conventional preambles shows that the designed sequence is superior in terms of (a fast burst synchronization in various transmission environments, (b fast AGC adjustment, and (c compliance of its spectrum with the spectral mask applied to the data transmit signal.

  7. Asymmetric Bimodal Exponential Power Distribution on the Real Line

    Directory of Open Access Journals (Sweden)

    Mehmet Niyazi Çankaya

    2018-01-01

    Full Text Available The asymmetric bimodal exponential power (ABEP distribution is an extension of the generalized gamma distribution to the real line via adding two parameters that fit the shape of peakedness in bimodality on the real line. The special values of peakedness parameters of the distribution are a combination of half Laplace and half normal distributions on the real line. The distribution has two parameters fitting the height of bimodality, so capacity of bimodality is enhanced by using these parameters. Adding a skewness parameter is considered to model asymmetry in data. The location-scale form of this distribution is proposed. The Fisher information matrix of these parameters in ABEP is obtained explicitly. Properties of ABEP are examined. Real data examples are given to illustrate the modelling capacity of ABEP. The replicated artificial data from maximum likelihood estimates of parameters of ABEP and other distributions having an algorithm for artificial data generation procedure are provided to test the similarity with real data. A brief simulation study is presented.

  8. Voting Power and Shareholder Activism

    DEFF Research Database (Denmark)

    Strand, Therese; Poulsen, Thomas; Thomsen, Steen

    2010-01-01

    The article discusses the development of a voting power theory that is applied to a unique data set on Swedish shareholder meetings. The authors hypothesize that there is a positive relationship between shareholder activism and the largest shareholder's sensitivity to greater participation by small...... shareholders. It is shown that firms' amenability to small shareholder influence results in more proposals by nomination committees that are dominated by large shareholders, but fewer proposals by other shareholders. The importance of local institutions are highlighted and a call for more research regarding...... shareholder activism in alternative institutional settings is mad...

  9. Relationship of the Functional Movement Screen In-Line Lunge to Power, Speed, and Balance Measures

    Science.gov (United States)

    Hartigan, Erin H.; Lawrence, Michael; Bisson, Brian M.; Torgerson, Erik; Knight, Ryan C.

    2014-01-01

    Background: The in-line lunge of the Functional Movement Screen (FMS) evaluates lateral stability, balance, and movement asymmetries. Athletes who score poorly on the in-line lunge should avoid activities requiring power or speed until scores are improved, yet relationships between the in-line lunge scores and other measures of balance, power, and speed are unknown. Hypothesis: (1) Lunge scores will correlate with center of pressure (COP), maximum jump height (MJH), and 36.6-meter sprint time and (2) there will be no differences between limbs on lunge scores, MJH, or COP. Study Design: Descriptive laboratory study. Level of Evidence: Level 3. Methods: Thirty-seven healthy, active participants completed the first 3 tasks of the FMS (eg, deep squat, hurdle step, in-line lunge), unilateral drop jumps, and 36.6-meter sprints. A 3-dimensional motion analysis system captured MJH. Force platforms measured COP excursion. A laser timing system measured 36.6-m sprint time. Statistical analyses were used to determine whether a relationship existed between lunge scores and COP, MJH, and 36.6-m speed (Spearman rho tests) and whether differences existed between limbs in lunge scores (Wilcoxon signed-rank test), MJH, and COP (paired t tests). Results: Lunge scores were not significantly correlated with COP, MJH, or 36.6-m sprint time. Lunge scores, COP excursion, and MJH were not statistically different between limbs. Conclusion: Performance on the FMS in-line lunge was not related to balance, power, or speed. Healthy participants were symmetrical in lunging measures and MJH. Clinical Relevance: Scores on the FMS in-line lunge should not be attributed to power, speed, or balance performance without further examination. However, assessing limb symmetry appears to be clinically relevant. PMID:24790688

  10. Relationship of the functional movement screen in-line lunge to power, speed, and balance measures.

    Science.gov (United States)

    Hartigan, Erin H; Lawrence, Michael; Bisson, Brian M; Torgerson, Erik; Knight, Ryan C

    2014-05-01

    The in-line lunge of the Functional Movement Screen (FMS) evaluates lateral stability, balance, and movement asymmetries. Athletes who score poorly on the in-line lunge should avoid activities requiring power or speed until scores are improved, yet relationships between the in-line lunge scores and other measures of balance, power, and speed are unknown. (1) Lunge scores will correlate with center of pressure (COP), maximum jump height (MJH), and 36.6-meter sprint time and (2) there will be no differences between limbs on lunge scores, MJH, or COP. Descriptive laboratory study. Level 3. Thirty-seven healthy, active participants completed the first 3 tasks of the FMS (eg, deep squat, hurdle step, in-line lunge), unilateral drop jumps, and 36.6-meter sprints. A 3-dimensional motion analysis system captured MJH. Force platforms measured COP excursion. A laser timing system measured 36.6-m sprint time. Statistical analyses were used to determine whether a relationship existed between lunge scores and COP, MJH, and 36.6-m speed (Spearman rho tests) and whether differences existed between limbs in lunge scores (Wilcoxon signed-rank test), MJH, and COP (paired t tests). Lunge scores were not significantly correlated with COP, MJH, or 36.6-m sprint time. Lunge scores, COP excursion, and MJH were not statistically different between limbs. Performance on the FMS in-line lunge was not related to balance, power, or speed. Healthy participants were symmetrical in lunging measures and MJH. Scores on the FMS in-line lunge should not be attributed to power, speed, or balance performance without further examination. However, assessing limb symmetry appears to be clinically relevant.

  11. CONCEPTS OF IMPROVING CURRENT PROTECTION OF POWER-GRID LINES

    Directory of Open Access Journals (Sweden)

    F. A. Romaniuk

    2015-01-01

    Full Text Available The  6–35  kV  power-grid  current  protection  serves  to  protect  the  transmission  lines against phase-to-phase short-circuits. The major disadvantage of it lies in the relatively large time delays of the last stages especially in the main sections of the grid owing to the stepped relay characteristics as well as a large number of the steps. A full-fledged protection of the 6–35 kV lines against inter-phase short circuits can be provided by the two-stage current protection: the first stage being the current cutoff without any time delay and the second stage – the maximum current protection where the time delay is linear contingent on the distance between the protection placement and the fault-point location. The article introduces the rating formulae for the time delays of the second-stage and their exemplary graphic presentation. The authors offer a variant for solving the problem with computation of the second-stage time delays in those instances where several feeders diverge from the bus bars of the substation located in the end of the protected line.Improving current protections for the 6–35 kV transmission lines with one-end power supply against interphase short-circuits can be based on the collective application of the following principles: accounting for the type and location of the short-circuit which provides for the high-performance cutoff zone instantaneous expansion and its independence on the mode of failure and the grid operation mode. It also allows increase of the last stage sensitiveness towards asymmetrical short-circuits; detection of the short-circuit location only on the results of fault currents measurement which simplifies the protection implementation; realization of the last (second protection stage with linear-dependent time delay which ensures potentiality of its operation speed increase.

  12. Performing maintenance activities on-line a risk perspective

    International Nuclear Information System (INIS)

    Darling, S.S.; Mairs, T.P.

    1993-01-01

    The US nuclear power industry is attempting to deal with the issue of optimizing the performance of maintenance activities with the advent of the maintenance rule. The impact of any maintenance activity on the safe operation of a nuclear power facility can be quantified on the basis of risk. Therefore, it is incumbent upon the industry to accommodate the regulator and present a maintenance optimization program in terms that explicitly address the potential risk inherent in its concept and implementation. The motivation for utilities to perform maintenance while the plant is operating (i.e., on-line) is readily perceived to offer the following advantages: 1. greater system availability; 2. higher plant capacity factor; 3. more evenly distributed workload for the maintenance department; and 4. overall safer plant operation. However, risks inherent in undertaking maintenance activities during power operation could amount to the realization that reapportionment of these tasks is not cost-beneficial. Therefore, it is important that any utility considering implementing such a paradigm in maintenance philosophy establish a rigorous process to select, perform, and monitor maintenance tasks performed while operating

  13. Impulsive Noise Characterization in Narrowband Power Line Communication

    Directory of Open Access Journals (Sweden)

    Li Bai

    2018-04-01

    Full Text Available Currently, narrowband Power line communication (PLC is considered an attractive communication system in smart grid environments for applications such as advanced metering infrastructure (AMI. In this paper, we will present a comprehensive comparison and analysis in time and frequency domain of noise measured in China and Italy. In addition, impulsive noise in these two countries are mainly analyzed and modeled using two probability based models, Middleton Class A (MCA model and α stable distribution model. The results prove that noise measured in China is rich in impulsive noise, and can be modeled well by α stable distribution model, while noise measured in Italy has less impulsive noise, and can be better modeled by the MCA model.

  14. Improving a Power Line Communications Standard with LDPC Codes

    Directory of Open Access Journals (Sweden)

    Hsu Christine

    2007-01-01

    Full Text Available We investigate a power line communications (PLC scheme that could be used to enhance the HomePlug 1.0 standard, specifically its ROBO mode which provides modest throughput for the worst case PLC channel. The scheme is based on using a low-density parity-check (LDPC code, in lieu of the concatenated Reed-Solomon and convolutional codes in ROBO mode. The PLC channel is modeled with multipath fading and Middleton's class A noise. Clipping is introduced to mitigate the effect of impulsive noise. A simple and effective method is devised to estimate the variance of the clipped noise for LDPC decoding. Simulation results show that the proposed scheme outperforms the HomePlug 1.0 ROBO mode and has lower computational complexity. The proposed scheme also dispenses with the repetition of information bits in ROBO mode to gain time diversity, resulting in 4-fold increase in physical layer throughput.

  15. Communication Characteristics of Faulted Overhead High Voltage Power Lines at Low Radio Frequencies

    Directory of Open Access Journals (Sweden)

    Nermin Suljanović

    2017-11-01

    Full Text Available This paper derives a model of high-voltage overhead power line under fault conditions at low radio frequencies. The derived model is essential for design of communication systems to reliably transfer information over high voltage power lines. In addition, the model can also benefit advanced systems for power-line fault detection and classification exploiting the phenomenon of changed conditions on faulted power line, resulting in change of low radio frequency signal propagation. The methodology used in the paper is based on the multiconductor system analysis and propagation of electromagnetic waves over the power lines. The model for the high voltage power line under normal operation is validated using actual measurements obtained on 400 kV power line. The proposed model of faulted power lines extends the validated power-line model under normal operation. Simulation results are provided for typical power line faults and typical fault locations. Results clearly indicate sensitivity of power-line frequency response on different fault types.

  16. Investigation of Orthogonal Frequency Division Multiplexing Based Power Line Communication Systems

    OpenAIRE

    Hosseinpour, Ali

    2015-01-01

    Power Line Communication (PLC) has the potential to become the preferred technique for providing broadband to homes and offices with the advantage of eliminating the need for new wiring infrastructure and reducing the cost. Power line grids, however, present a hostile channel for data communication, since the fundamental purpose of the power line channel was only the transmission of electric power at 50/60 Hz frequencies. The development of PLC systems for providing broadband applications req...

  17. In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Mueller Steffen; Wibbing Sascha; Weigel Robert; Koelpin Alexander; Dennerlein, Juergen; Janke, Iryna; Weber, Johannes

    2015-01-01

    Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails

  18. In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Mueller Steffen; Wibbing Sascha; Weigel Robert; Koelpin Alexander [Institute for Electronics Engineering, University of Erlangen-Nuremberg (Germany); Dennerlein, Juergen; Janke, Iryna; Weber, Johannes [AREVA GmbH, Paul-Gossen-Str. 100, 91052 Erlangen (Germany)

    2015-07-01

    Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails

  19. Optimal design and routing of power lines; ecological, technical and economic perspectives (OPTIPOL)

    Energy Technology Data Exchange (ETDEWEB)

    Bevanger, K.; Bartzke, G.; Broeseth, H.; Gjershaug, J.O.; Hanssen, F.; Jacobsen, K.-O.; Kvaloey, P.; May, R.; Meaas, R.; Nygaard, T.; Refsnaes, S.; Stokke, S.; Vang, R.

    2010-12-15

    The OPTIPOL project - 'Optimal design and routing of power lines; ecological, technical and economic perspectives' - has been active for two years, although the main operational phase was delayed until autumn 2009. The overall OPTIPOL objective is to develop knowledge and tools to improve the decision on environmental friendly power-line routing. To achieve this goal the work is subdivided into 9 focal areas; Develop a 'least-cost path' GIS-based application for an environmental friendly routing of power lines based on ecological, financial and technological criteria; Assess habitat use of power-line Rights-of-Way (ROW) by different wildlife species, consider actions of improving power-line ROW as wildlife habitats, and evaluate possible positive and negative effects on wildlife of power-line ROWs. More specific we will examine how power-line ROW may offer suitable feeding grounds for moose and see if the species habitat selection is influenced by power line ROW; Assess population impact of bird mortality due to power-line collisions, relative to other human related mortality factors (primarily hunting) in gallinaceous birds (with capercaillie and black grouse as model species); Identify ecological high-risk factors for bird collisions, i.e. site-specific factors connected to topographic characteristics, including vegetation structure, season, weather and light conditions; Establish a national infrastructure for management of dead bird data (including birds re-corded as collision and electrocution victims) by developing an online web application enabling the general public to contribute with data on recorded dead birds via Internet; Review available literature to assess 1) the possibilities for increased collision hazard to birds by making power-line structures less visible for humans given the present knowledge on bird vision, and 2) technical properties and constraints of camouflaging techniques on conductors and earth wires; Review available

  20. Optimal design and routing of power lines; ecological, technical and economic perspectives (OPTIPOL). Progress report 2009

    Energy Technology Data Exchange (ETDEWEB)

    Bevanger, K.; Bartzke, G.; Broeseth, H.; Gjershaug, J.O.; Hanssen, F.; Jacobsen, K.-O.; Kvaloey, P.; May, R.; Nygaard, T.; Pedersen, H.C.; Reitan, O.; Refsnaes, S.; Stokke, S.; Vang, R.

    2009-12-15

    From 2009 inclusive, NINA has received economic support for research on power lines and wildlife from the Norwegian Research Council (NFR) through the RENERGI Programme. The project is named 'Optimal design and routing of power lines; ecological, technical and economic perspectives' (OPTIPOL). It is scheduled for 5 years (2009-1013) and is part of the activities within CEDREN, i.e. the Centre for environmental design of renewable energy (cf. http://www.cedren.no). With a grid close to 200 000 km overhead power-lines, the associated rights-of-way (ROW) affect huge land areas in Norway. The overall goal is to develop predict-ing tools for optimal routing of power lines from an environmental perspective and assess technical and economic solutions to minimize conflicts with wildlife and habitat conservation. Thus, the OPTIPOL rationale is based on the belief that the negative effects of electricity transmission and distribution can be reduced with respect to birds and mammals. OPTIPOL has several ambitious objectives, and is divided into sub-projects and specific tasks. From the first of November a PhD-student became part of the project, a position that will be held for 4 years. The main objective of the PhD-activities will be to assess how and why different wildlife species use deforested areas below power lines, evaluate possible positive and negative effects of power-line ROWs, and assess the possibilities for quality improvement. Another part of the project is dedicated the effects of linear structures on movement patterns and distribution in the landscape in native deer species. Here we will examine how different spatial scales influence the processes that guide movement patterns, and responses to linear structures. Another focus will be small game species, with mountain hare, capercaillie, black grouse and hazel grouse as model species. The main objective will be to assess the impact of transforming ROW habitats into attractive small-game foraging

  1. Moderator inlet line hanger replacement for Pickering nuclear power station

    International Nuclear Information System (INIS)

    Kirkpatrick, R.A.; Bowman, J.M.; Symmons, W.R.; El-Nesr, S.

    1988-01-01

    Ontario Hydro's Pickering Nuclear Generating Station (PNGS), Units 1 and 2 were shutdown for large scale fuel channel replacement. Other nonroutine inspection and maintenance activities were performed to determine the overall condition of the units and it was seen that a moderator inlet line hanger (identified as HR-29) had failed in both units. Subsequent inspections during planned maintenance outages of Pickering NGS Units 3 and 4 revealed that hanger HR-29 had failed and required replacement. A research program was conducted to find a suitable technique. These problems included accessing tooling through small inspection ports, manipulating tooling from a significant distance and the high radiation fields within the vault. This paper describes the program undertaken to replace hanger HR-29. (author)

  2. Strategies for Power Line Communications Smart Metering Network Deployment

    Directory of Open Access Journals (Sweden)

    Alberto Sendin

    2014-04-01

    Full Text Available Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS existing in the grid, covering the Low Voltage (LV segment with the lowest possible costs. Power Line Communications (PLC have been extensively used in electricity grids for a variety of purposes and, of late, have been the focus of renewed interest. PLC are really well suited for quick and inexpensive pervasive deployments. However, no LV grid is the same in any electricity company (utility, and the particularities of each grid evolution, architecture, circumstances and materials, makes it a challenge to deploy Smart Metering networks with PLC technologies, with the Smart Grid as an ultimate goal. This paper covers the evolution of Smart Metering networks, together with the evolution of PLC technologies until both worlds have converged to project PLC-enabled Smart Metering networks towards Smart Grid. This paper develops guidelines over a set of strategic aspects of PLC Smart Metering network deployment based on the knowledge gathered on real field; and introduces the future challenges of these networks in their evolution towards the Smart Grid.

  3. An electromagnetic field measurement protocol for monitoring power lines

    International Nuclear Information System (INIS)

    Lubritto, C.; Iavazzo, A.; D'Onofrio, A.; Palmieri, A.; Sabbarese, C.; Terrasi, F.

    2002-01-01

    In the actions aiming to prevent risks related to the exposure to Low Frequencies Non Ionising electromagnetic Radiations (ELF-NIR), always arises the need to perform measurements in order to assess the field level existing in the considered sites. As a matter of fact very often it turns out difficult to predict, on the base of calculations, with sufficient approximation the field levels, due to extended variability of environmental conditions (e.g. coexistence of several sources, ground and building conformation, etc..). The measurement procedures must follow a methodology that could allow to minimise the interferences with the measurement set-up and the systematic and accidental errors. Risks for the operator and damages to the instrument should also be taken into account. One of the goal set for this research program was then the definition of the measurement protocol for electromagnetic field generated by low frequency non ionising radiation sources. In particular sources like power lines will be considered in order to validate the protocol by means of in-field measurements

  4. Power-line electrocution of birds (Electrocucion de Aves en Lineas Electricas en Mexico)

    Science.gov (United States)

    Patricia Manzano Fischer

    2006-01-01

    A result of rapid growth in human population and energy use, is proliferating power lines that electrocute birds, killing eagles and causing power outages. The United States was one of the first countries to recognize the significance of this problem. Suggested Practices for the Protection of Raptors on Power Lines, first published in the 1970s, has now been translated...

  5. Power in health care organizations: contemplations from the first-line management perspective.

    Science.gov (United States)

    Isosaari, Ulla

    2011-01-01

    The aim of this paper is to examine health care organizations' power structures from the first-line management perspective. What liable power structures derive from the theoretical bases of bureaucratic, professional and result based organizations, and what power type do health care organizations represent, according to the empirical data? The paper seeks to perform an analysis using Mintzberg's power configurations of instrument, closed system, meritocracy and political arena. The empirical study was executed at the end of 2005 through a survey in ten Finnish hospital districts in both specialized and primary care. Respondents were all first-line managers in the area and a sample of staff members from internal disease, surgical and psychiatric units, as well as out-patient and primary care units. The number of respondents was 1,197 and the response percentage was 38. The data were analyzed statistically. As a result, it can be seen that a certain kind of organization structure supports the generation of a certain power type. A bureaucratic organization generates an instrument or closed system organization, a professional organization generates meritocracy and also political arena, and a result-based organization has a connection to political arena and meritocracy. First line managers regarded health care organizations as instruments when staff regarded them mainly as meritocracies having features of political arena. Managers felt their position to be limited by rules, whereas staff members regarded their position as having lots of space and influence potential. If the organizations seek innovative and active managers at the unit level, they should change the organizational structure and redistribute the work so that there could be more space for meaningful management. This research adds to the literature and gives helpful suggestions that will be of interest to those in the position of first-line management in health care.

  6. State of technology, system and solution supporting on-line maintenance - company's activities and products

    International Nuclear Information System (INIS)

    Nishitani, Junichi; Shimizu, Shunichi; Higasa, Hisakazu

    2010-01-01

    The new inspection system based on operator's maintenance and monitoring program of nuclear power plants was introduced in Japan more than one year ago and recommended on-line maintenance (maintenance during operation) will be carried out to increase capacity factor with safe and reliable operation of the plant. In this feature article, nine experts described the state of technology, system and solution supporting on-line maintenance - company's activities and products. These were titled as 'MHI's technology supporting on-line maintenance'. 'Technology supporting on-line maintenance - Toshiba's activities to upgrade monitoring and diagnostic service and maintenance management', 'AsahiKASEI's activities of on-line maintenance', 'Importance of information sharing of on-line maintenance and its ideal method-function of impact plan of IBM Maximo Asset Management for Nuclear', 'US's on-line maintenance and information systems', 'SmartProcedures realizing safe operation of nuclear power plant - proposal of computerized procedures', 'Ultrasonic leak detection system SDT170', 'Application of infrared thermography for equipment maintenance in nuclear power plant' and 'On-line condition monitoring system - condition eye'. (T. Tanaka)

  7. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid

    Directory of Open Access Journals (Sweden)

    Bat-erdene Byambasuren

    2016-02-01

    Full Text Available Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results.

  8. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid.

    Science.gov (United States)

    Byambasuren, Bat-Erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar

    2016-02-19

    Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results.

  9. OLDES - an on-line dose evaluation system that can be integrated into the remote monitoring system of nuclear power stations for additional monitoring and prognostic assessment in case of major accidental activity release

    International Nuclear Information System (INIS)

    Witt, H. de; Brenk, H.D.; Kruschel, K.P.; Knaup, A.G.

    1986-01-01

    Remote monitoring systems are an inherent part of the environmental surveillance installations of most commercial LWR power plants in the FRG. The systems are designed to cover routine and accident situations. They provide meteorological data, gross effluent dose rates, and dose measurements at approximately 25 locations in the vicinity of the plant in time steps of 10 minutes. Based on such a network, an attempt has been made to develop an on-line dose evaluation system (OLDES) as a tool to aid decision making processes in case of major accidental releases. On-line, here means that the software package directly includes the measurements at the monitoring stations in order to adjust the dose computations to the measurements in time steps of 10 minutes. In this way the system yields the best possible bases, both for actual diagnosis of radiation exposure, and for dose projections. The software package uses a Gaussian puff trajectory model to simulate atmospheric dispersion and deposition of radionuclides. It includes 'cloud- and ground-shine irradiation' and allows for changing weather conditions without exceeding the limits of real time calculation. Preliminary tests of the software package revealed reasonable semioperational performance. (orig.)

  10. Residential mobility of populations near UK power lines and implications for childhood leukaemia

    International Nuclear Information System (INIS)

    Swanson, John

    2013-01-01

    Epidemiological studies suggest associations between childhood leukaemia and living near high-voltage power lines, but the most obvious potential causative agent, the magnetic fields produced by the power lines, is not supported by laboratory studies or a known mechanism. An alternative hypothesised explanation is if there is greater population mobility near power lines, linking to the findings of Kinlen that population mixing increases leukaemia rates. We used the names recorded in electoral registers to see whether people near power lines move house more often than the population as a whole. We did find variations, but only small ones, and not such as to support the hypothesis. (note)

  11. A METEOROLOGICAL RISK ASSESSMENT METHOD FOR POWER LINES BASED ON GIS AND MULTI-SENSOR INTEGRATION

    Directory of Open Access Journals (Sweden)

    Z. Lin

    2016-06-01

    Full Text Available Power lines, exposed in the natural environment, are vulnerable to various kinds of meteorological factors. Traditional research mainly deals with the influence of a single meteorological condition on the power line, which lacks of comprehensive effects evaluation and analysis of the multiple meteorological factors. In this paper, we use multiple meteorological monitoring data obtained by multi-sensors to implement the meteorological risk assessment and early warning of power lines. Firstly, we generate meteorological raster map from discrete meteorological monitoring data using spatial interpolation. Secondly, the expert scoring based analytic hierarchy process is used to compute the power line risk index of all kinds of meteorological conditions and establish the mathematical model of meteorological risk. By adopting this model in raster calculator of ArcGIS, we will have a raster map showing overall meteorological risks for power line. Finally, by overlaying the power line buffer layer to that raster map, we will get to know the exact risk index around a certain part of power line, which will provide significant guidance for power line risk management. In the experiment, based on five kinds of observation data gathered from meteorological stations in Guizhou Province of China, including wind, lightning, rain, ice, temperature, we carry on the meteorological risk analysis for the real power lines, and experimental results have proved the feasibility and validity of our proposed method.

  12. On-line neutron activation analyzers

    International Nuclear Information System (INIS)

    Flahaut, V.; Colmon, A.

    1999-01-01

    A neutronic analyser has been designed to determine the composition of the flow of raw materials entering a cement factory on the conveyor belt. This new system gives a reliable analysis of the whole cargo that outdates the sampling or the usual surface analysis based on fluorescence spectrometry. The accuracy is about 1%.The neutrons interact with the materials on an average depth of 25 cm and are absorbed by nuclei, these nuclei produce photons whose energy is characteristic of the chemical element itself. The composition can be deduced by measuring the number of photons emitted and their energy. The analysis is made on-line and can concern the search for about 10 compounds. In the case of cement the list of compounds is: SiO 2 , CaO, Al 2 O 3 , Fe 2 O 3 , MgO, Na 2 O, TiO 2 , S, Mn 2 O 3 , K 2 O, and H 2 O. The neutron generator involves a deuterium ion source whose deuterium ions are accelerated by means of an electrical field and impinge on a tritiated target, the nuclear reactions between deuterium and tritium produce 14 MeV neutrons. This neutron analysing technique can be adapted to any need of on-line composition determination. (A.C.)

  13. Environmental pollution by magnetic field associated with power transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Hamza, Abdel-Salam H. A.; Ghania, Samy M. [Faculty of Engineering, Zagazig University (Banha Branch), 9-EI-Hakim Be-Amr EI-Ahh Str, EI- Khalafawy, Shoubra, Cairo (Egypt); Mohmoudh, Shaher A. [Ministry of Electricity and Energy (Egypt)

    2002-11-01

    Environmental pollution has a major effect on human health and other life types. A source of environmental pollution is the magnetic field produced near high and extra high voltage (EHV) transmission lines. Magnetic fields from AC EHV lines have been discussed in this paper. The field profiles and their contribution to environmental pollution are studied, these being under transmission lines with different line system configurations, using the three dimensional approaches. These line system configurations are more commonly used in Egypt and other countries. The obtained results are found to be useful for discussing the comparison of the field densities on the human body and other life types at the ground level under or near the lines. (Author)

  14. The Evaluation Method of the Lightning Strike on Transmission Lines Aiming at Power Grid Reliability

    Science.gov (United States)

    Wen, Jianfeng; Wu, Jianwei; Huang, Liandong; Geng, Yinan; Yu, zhanqing

    2018-01-01

    Lightning protection of power system focuses on reducing the flashover rate, only distinguishing by the voltage level, without considering the functional differences between the transmission lines, and being lack of analysis the effect on the reliability of power grid. This will lead lightning protection design of general transmission lines is surplus but insufficient for key lines. In order to solve this problem, the analysis method of lightning striking on transmission lines for power grid reliability is given. Full wave process theory is used to analyze the lightning back striking; the leader propagation model is used to describe the process of shielding failure of transmission lines. The index of power grid reliability is introduced and the effect of transmission line fault on the reliability of power system is discussed in detail.

  15. Optimal design and routing of power lines; ecological, technical and economic perspectives (OPTIPOL). Progress report 2012

    Energy Technology Data Exchange (ETDEWEB)

    Bevanger, Kjetil; Bartzke, Gundula; Broeseth, Henrik; Dahl, Espen Lie; Gjershaug, Jan Ove; Hanssen, Frank; Jacobsen, Karl-Otto; Kleven, Oddmund; Kvaloey, Paal; May, Roel; Meaas, Roger; Nygaaard, Torgeir; Resnaes, Steinar; Stokke, Sigbjoern; Thomassen, Joern

    2012-07-01

    respectively. WP6 and WP7. In WP9 'Hubro-population effects of mortality due to power line', four juveniles were equipped with GPS satellite transmitters in 2012, in addition to one adult male and one adult female. Spring for DNA analysis were collected from active nests also in 2012, and analyzes of feathers collected in 2009-2012 has started. An oral presentation, 'Mitigating eagle owl electrocution in Norway', was presented and submitted as contributions to the proceeding paper at the 10th ROW conference in Arizona.(Author)

  16. Using meteorological forecasts in on-line predictions of wind power

    DEFF Research Database (Denmark)

    Nielsen, Torben Skov; Nielsen, Henrik Aalborg; Madsen, Henrik

    1999-01-01

    This report describes a model investigation into wind power prediction model as well as a tool for predicting the power production from wind turbines in an area - the Wind Power Prediction Tool (WPPT). The predictions are based on on-line measurements of power production for a selected set...

  17. Millimeter-Gap Magnetically Insulated Transmission Line Power Flow Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Hutsel, Brian Thomas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stoltzfus, Brian S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Fowler, William E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LeChien, Keith R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mazarakis, Michael G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Moore, James K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mulville, Thomas D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Savage, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stygar, William A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); McKenney, John L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Peter A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacRunnels, Diego J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Long, Finis W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Porter, John L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs). The platform was driven by the 400-GW Mykonos-V accelerator. The experiments conducted quantify the current loss in a millimeter-gap MITL with respect to vacuum conditions in the MITL for two different gap distances, 1.0 and 1.3 mm. The current loss for each gap was measured for three different vacuum pump down times. As a ride along experiment, multiple shots were conducted with each set of hardware to determine if there was a conditioning effect to increase current delivery on subsequent shots. The experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps. The 1.0 mm gap resulted in current loss of 40%-60% of peak current. The 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps. The experiments result s indicate that the vacuum pressure or pump down time did not have a significant effect on the measured current loss at vacuum pressures between 1e-4 and 1e-5 Torr. Additionally, there was not repeatable evidence of a conditioning effect that reduced current loss for subsequent full-energy shots on a given set of hardware. It should be noted that the experiments conducted likely did not have large loss contributions due to ion emission from the anode due to the relatively small current densi-ties (25-40 kA/cm) in the MITL that limited the anode temperature rise due to ohmic heating. The results and conclusions from these experiments may have limited applicability to MITLs of high current density (>400 kA/cm) used in the convolute and load region of the Z which experience temperature increases of >400° C and generate ion emission from anode surfaces.

  18. An ultra low-power off-line APDM-based switchmode power supply with very high conversion efficiency

    DEFF Research Database (Denmark)

    Nielsen, Nils

    2001-01-01

    This article describes the results from the research work on design of a ultra low power off-line power supply with very high conversion efficiency. The input voltage is 230 VAC nominal and output voltage is 5 VDC. By ultra low power levels, an output power level in the area ranging from 50 m......W and up to 1000 mW is meant. The small power supply is intended for use as a standby power supply in mains operated equipment, which requires a small amount of power in standby mode....

  19. Active Power Controls from Wind Power: Bridging the Gaps

    Energy Technology Data Exchange (ETDEWEB)

    Ela, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gevorgian, V. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Fleming, P. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Zhang, Y. C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Singh, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muljadi, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Scholbrook, A. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Aho, J. [Univ. of Colorado, Boulder, CO (United States); Buckspan, A. [Univ. of Colorado, Boulder, CO (United States); Pao, L. [Univ. of Colorado, Boulder, CO (United States); Singhvi, V. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Tuohy, A. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Pourbeik, P. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Brooks, D. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Bhatt, N. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States)

    2014-01-01

    This paper details a comprehensive study undertaken by the National Renewable Energy Laboratory, Electric Power Research Institute, and the University of Colorado to understand how the contribution of wind power providing active power control (APC) can benefit the total power system economics, increase revenue streams, improve the reliability and security of the power system, and provide superior and efficient response while reducing any structural and loading impacts that may reduce the life of the wind turbine or its components. The study includes power system simulations, control simulations, and actual field tests using turbines at NREL's National Wind Technology Center (NWTC). The study focuses on synthetic inertial control, primary frequency control, and automatic generation control, and analyzes timeframes ranging from milliseconds to minutes to the lifetime of wind turbines, locational scope ranging from components of turbines to large wind plants to entire synchronous interconnections, and additional topics ranging from economics to power system engineering to control design.

  20. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage power lines. 56.12071 Section 56.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than trolley...

  1. On-line control systems in power plants

    International Nuclear Information System (INIS)

    Freymeyer, P.

    1981-01-01

    This report is a review of on-line control systems as a complex system connected with all problems like, development, planning, degree of automation, economics, service, quality and documentation. (orig.) [de

  2. Effects of power-line construction on wetland vegetation in Massachusetts, USA

    Science.gov (United States)

    Nickerson, Norton H.; Dobberteen, Ross A.; Jarman, Nancy M.

    1989-07-01

    Utility rights-of-way corridors through wetland areas generate long-term impacts from construction activities to these valuable ecosystems. Changes to and recovery of the vegetation communities of a cattail marsh, wooded swamp, and shrub/bog wetland were documented through measurements made each growing season for two years prior, five years following, and again on the tenth year after construction of a 345-kV transmission line. While both the cattail marsh and wooded swamp recovered within a few years, measures of plant community composition in the shrub/bog wetland were still lower, compared to controls, after ten years. Long-term investigations such as the one reported here help decrease uncertainty and provide valuable information for future decision making regarding construction of power utility lines through valuable and dwindling wetland resources.

  3. Antiproliferative activity of flavonoids on several cancer cell lines.

    Science.gov (United States)

    Kawaii, S; Tomono, Y; Katase, E; Ogawa, K; Yano, M

    1999-05-01

    Twenty-seven Citrus flavonoids were examined for their antiproliferative activities against several tumor and normal human cell lines. As a result, 7 flavonoids were judged to be active against the tumor cell lines, while they had weak antiproliferative activity against the normal human cell lines. The rank order of potency was luteolin, natsudaidain, quercetin, tangeretin, eriodictyol, nobiletin, and 3,3',4',5,6,7,8-heptamethoxyflavone. The structure-activity relationship established from comparison among these flavones and flavanones showed that the ortho-catechol moiety in ring B and a C2-C3 double bond were important for the antiproliferative activity. As to polymethoxylated flavones, C-3 hydroxyl and C-8 methoxyl groups were essential for high activity.

  4. Calculation of the Magnetic Fields of the Electric Power Line

    Directory of Open Access Journals (Sweden)

    Patsiuk V.

    2016-12-01

    Full Text Available The task of calculation of per unit length parameters of multi-conductor electrical overhead transmission lines has been treated in the paper. The calculation of distribution of electric and magnetic fields has been performed by means of the finite volume method for entire span of the line. The theoretical justification of the method for calculation the parameters of electromagnetic field taking into account the change of the vector of magnetic potential along the line has been given. The problems of electrostatic and magnetostatic for a single electric conductor and unlimited long conductor with current have been solved. For the inner and total inductivities of a single conductor under the current have been obtained relationships and drawn dependences. Dependence between the speeds of light and of electromagnetic wave’s propagation has been presented. Based on the characteristics of distribution of electric and magnetic fields of multi-conductor lines has been provided the method of calculation of the matrix of own and mutual capacitances and inductivities the calculated values of per unit length parameters of compact 110 kV electric line which is in concordance with one of basic physical constant – the speed of light.

  5. Extended emission-line regions in active galaxies

    International Nuclear Information System (INIS)

    Hutchings, J.B.; Hickson, P.

    1988-01-01

    Long-slit spectra of four active galaxies in the redshift range 0.06-0.10 are presented. Two have interacting companions. Spectra of the galaxies show extended narrow emission lines in all cases. Continuum color changes, emision-line ratio changes, and velocity changes with 1 arcsec resolution can be detected. Relative velocities between AGN and companion galaxies are also given. These objects appear to lie in galaxies in which there is considerable star-formation activity, and very extended line emision. 20 references

  6. Active power compensator of the current harmonics based on the instantaneous power theory

    Directory of Open Access Journals (Sweden)

    Marian GAICEANU

    2005-12-01

    Full Text Available The quality of the electrical current becomes a major concern. The proliferation of the power electronic converters, which are used extensively to control electrical apparatus in industrial and commercial applications (dc and ac variable speed motor drives, induction furnaces, power line conditioners, and industrial power supplies, is at the origin of the AC current distribution network pollution and the reactive power demand. These power electronic converters typically draw non-sinusoidal currents from the utility, causing interference with adjacent sensitive loads and limit the utilization of the available electrical supply. The quality of the electrical current thus becomes a significant concern for the distributors of energy and their customers. Recent progress as regards technology of the power electronics brings a capacity of compensation and correction of the harmonic distortion generated by the nonlinear loads. In this paper a parallel active filter prototype capable of reducing the total harmonic distortion in the supply for most current source or adjustable speed drive type loads is presented. A 33 kVA active power filter was developed for harmonic and reactive power compensation based on the instantaneous power theory. The active filter configuration requires the measurement of both the load and filter currents. Experimental results from a prototype active power filter confirm the suitability of the proposed approach. The actual 33kVA prototype converter has been built and tested in the SIEI S.p.A. (Italy laboratory under the Marie Curie Post Doctoral research. The active power compensator is controlled by a high performance DSP platform, resulting in the following active filter features: source current reduction up to the 25th harmonic, 10% THD achievable for current source type loads, efficiency above 97%, does not cause resonance with other loads, operation in the presence of unbalanced loads, reactive power and harmonics

  7. Safe and easy power injection of contrast material through a central line

    International Nuclear Information System (INIS)

    Rogalla, P.; Meiri, N.; Hamm, M.B.; Thoeni, R.F.; Goldberg, H.I.

    1998-01-01

    Power-assisted injection of contrast material into an antecubital vein is commonly used in CT and has been proven superior to manual injection. Power-assisted injection through a central line bares the risk of rupturing the line because manual control over the pressure applied by the power injector is lacking. We present a simple safety device which allows manual control of the pressure by means of an interposed three-way stopcock combined with a small syringe for pressure equalization. (orig.)

  8. Assessment of environmental impact of HVDC power lines in terms of corona currents

    International Nuclear Information System (INIS)

    Tikhodeev, N.N.

    1997-01-01

    Corona loss measurements were made on a HVDC power transmission line to evaluate current density. Ion currents were obtained from unipolar and bipolar 400 to 1000 kV DC test lines. A numerical solution was proposed for assessing the maximum current density of unipolar corona currents near the lines. A larger ground clearance of line conductors was proposed as being the most effective way of lowering the current density. 11 refs., 2 tabs., 4 figs

  9. Power to Production: Activity Guide.

    Science.gov (United States)

    Massachusetts Univ., Lowell. Tsongas Industrial History Center.

    This field trip program consists of a 90-minute interpretive tour and a 90-minute hands-on workshop. The tour and workshop explore the role of water power in the Industrial Revolution. On the tour, students discover firsthand the unique resources of Lowell, Massachusetts, and the Park, while the workshop brings these historic resources to life as…

  10. VT Green Mountain Power Line Data (Overhead Only)

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) Green Mountain Power (GMP) pole and OVERHEAD linear distribution/sub-transmission model data. THE LINEAR DISTRIBUTION LAYER ONLY INCLUDES OVERHEAD...

  11. 47 CFR 15.113 - Power line carrier systems.

    Science.gov (United States)

    2010-10-01

    ....113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional... shall submit the details of all existing systems plus any proposed new systems or changes to existing... operation on electric lines which connect the distribution substation to the customer or house wiring. Such...

  12. WPPT, a tool for on-line wind power prediction

    Energy Technology Data Exchange (ETDEWEB)

    Skov Nielsen, T. [Dept. of Mathematical Modelling (IMM-DTU), Kgs. Lyngby (Denmark); Madsen, H. [Dept. of Mathematical Modelling (IMM-DTU) Kgs. Lyngby (Denmark); Toefting, J. [Elsam, Fredericia (Denmark)

    2004-07-01

    This paper dsecribes VPPT (Wind Power Prediction Tool), an application for assessing the future available wind power up to 36 hours ahead in time. WPPT has been installed in the Eltra/Elsam central dispatch center since October 1997. The paper describes the prediction model used, the actual implementation of WPPT as well as the experience gained by the operators in the dispatch center (au)

  13. ELF field in the proximity of complex power line configuration measurement procedures

    International Nuclear Information System (INIS)

    Benes, M.; Comelli, M.; Villalta, R.

    2006-01-01

    The issue of how to measure magnetic induction fields generated by various power line configurations, when there are several power lines that run across the same exposure area, has become a matter of interest and study within the Regional Environment Protection Agency of Friuli Venezia Giulia. In classifying the various power line typologies the definition of double circuit line was given: in this instance the magnetic field is determined by knowing the electrical and geometric parameters of the line. In the case of independent lines instead, the field is undetermined. It is therefore pointed out how, in the latter case, extracting projected information from a set of measurements of the magnetic field alone is impossible. Making measurements throughout the territory of service has in several cases offered the opportunity to define standard operational procedures. (authors)

  14. Electric Power Lines : Questions and Answers on Research into Health Effects.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1994-05-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this booklet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

  15. Integration of a hydraulic production plant in a weak power system on a long radial line

    Energy Technology Data Exchange (ETDEWEB)

    Lariviere, P. [Hydro-Quebec TransEnergie, 5655 de Marseille, Montreal, Quebec (Canada); Racine, M. [Hydro-Quebec TransEnergie, C.P. 10 000, Montreal, Quebec (Canada)

    2009-03-15

    Integrating power plants on long lines and weak power systems requires some care. To this effect, a study was conducted to determine if severe disturbances could result when a hydraulic production plant is integrated along a very long radial transmission line. Frequency responses were evaluated to identify possible resonant system operating conditions. Many events such as faults, transformer energyzing and line opening were investigated. All power plant synchronous machines were represented including exciter and governor regulators. Impact of dynamic modeling of the load was examined. The study demonstrates that the overall protective strategy implemented will limit worst overvoltage constraints imposed to equipment and load within an acceptable level. (author)

  16. Residential Distance to High-voltage Power Lines and Risk of Neurodegenerative Diseases

    DEFF Research Database (Denmark)

    Frei, Patrizia; Poulsen, Aslak Harbo; Mezei, Gabor

    2013-01-01

    period 5-20 years before diagnosis were computed. The risks for developing dementia, Parkinson's disease, multiple sclerosis, and motor neuron disease were not increased in persons living within close vicinity of a power line. The risk of Alzheimer's disease was not increased for ever living within 50 m...... of a power line (hazard ratio = 1.04, 95% confidence interval: 0.69, 1.56). No dose-response according to number of years of living within 50 m of a power line was observed, but there were weak indications of an increased risk for persons diagnosed by the age of 75 years. Overall, there was little support...

  17. Antibacterial and anti-breast cancer cell line activities of ...

    African Journals Online (AJOL)

    Purpose: To evaluate the activity of extracts of Sanghuangporus sp.1 fungus against pathogenic bacteria and a breast cancer cell line. Methods: The wild fruiting body and mycelium of Sanghuangporus sp.1 were extracted with water and ethanol by ultrasonication extraction. The activity of the extracts against pathogenic ...

  18. Analysis of Power Network for Line Reactance Variation to Improve Total Transmission Capacity

    Directory of Open Access Journals (Sweden)

    Ikram Ullah

    2016-11-01

    Full Text Available The increasing growth in power demand and the penetration of renewable distributed generations in competitive electricity market demands large and flexible capacity from the transmission grid to reduce transmission bottlenecks. The bottlenecks cause transmission congestion, reliability problems, restrict competition, and limit the maximum dispatch of low cost generations in the network. The electricity system requires efficient utilization of the current transmission capability to improve the Available Transfer Capability (ATC. To improve the ATC, power flow among the lines can be managed by using Flexible AC Transmission System (FACTS devices as power flow controllers, which alter the parameters of power lines. It is important to place FACTS devices on suitable lines to vary the reactance for improving Total Transmission Capacity (TTC of the network and provide flexibility in the power flow. In this paper a transmission network is analyzed based on line parameters variation to improve TTC of the interconnected system. Lines are selected for placing FACTS devices based on real power flow Performance Index (PI sensitivity factors. TTC is computed using the Repeated Power Flow (RPF method using the constraints of lines thermal limits, bus voltage limits and generator limits. The reactance of suitable lines, selected on the basis of PI sensitivity factors are changed to divert the power flow to other lines with enough transfer capacity available. The improvement of TTC using line reactance variation is demonstrated with three IEEE test systems with multi-area networks. The results show the variation of the selected lines’ reactance in improving TTC for all the test networks with defined contingency cases.

  19. CALCULATION METHOD OF ELECTRIC POWER LINES MAGNETIC FIELD STRENGTH BASED ON CYLINDRICAL SPATIAL HARMONICS

    Directory of Open Access Journals (Sweden)

    A.V. Erisov

    2016-05-01

    Full Text Available Purpose. Simplification of accounting ratio to determine the magnetic field strength of electric power lines, and assessment of their environmental safety. Methodology. Description of the transmission lines of the magnetic field by using techniques of spatial harmonic analysis in the cylindrical coordinate system is carried out. Results. For engineering calculations of electric power lines magnetic field with sufficient accuracy describes their first spatial harmonic magnetic field. Originality. Substantial simplification of the definition of the impact of the construction of transmission line poles on the value of its magnetic field and the bands of land alienation sizes. Practical value. The environmentally friendly projection electric power lines on the level of the magnetic field.

  20. Emission line galaxies and active galactic nuclei in WINGS clusters

    Science.gov (United States)

    Marziani, P.; D'Onofrio, M.; Bettoni, D.; Poggianti, B. M.; Moretti, A.; Fasano, G.; Fritz, J.; Cava, A.; Varela, J.; Omizzolo, A.

    2017-03-01

    We present the analysis of the emission line galaxies members of 46 low-redshift (0.04 employing diagnostic diagrams. We examined the emission line properties and frequencies of star-forming galaxies, transition objects, and active galactic nuclei (AGNs: LINERs and Seyferts), unclassified galaxies with emission lines, and quiescent galaxies with no detectable line emission. A deficit of emission line galaxies in the cluster environment is indicated by both a lower frequency, and a systematically lower Balmer emission line equivalent width and luminosity with respect to control samples; this implies a lower amount of ionized gas per unit mass and a lower star formation rate if the source is classified as Hii region. A sizable population of transition objects and of low-luminosity LINERs (≈ 10-20% of all emission line galaxies) are detected among WINGS cluster galaxies. These sources are a factor of ≈1.5 more frequent, or at least as frequent, as in control samples with respect to Hii sources. Transition objects and LINERs in clusters are most affected in terms ofline equivalent width by the environment and appear predominantly consistent with so-called retired galaxies. Shock heating can be a possible gas excitation mechanism that is able to account for observed line ratios. Specific to the cluster environment, we suggest interaction between atomic and molecular gas and the intracluster medium as a possible physical cause of line-emitting shocks. The data whose description is provided in Table B.1, and emission line catalog of the WINGS database are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/599/A83

  1. Converging cylindrical magnetohydrodynamic shock collapse onto a power-law-varying line current

    KAUST Repository

    Mostert, W.; Pullin, D. I.; Samtaney, Ravi; Wheatley, V.

    2016-01-01

    We investigate the convergence behaviour of a cylindrical, fast magnetohydrodynamic (MHD) shock wave in a neutrally ionized gas collapsing onto an axial line current that generates a power law in time, azimuthal magnetic field. The analysis is done

  2. Power Line Interference Removal from Electrocardiogram Using a Simplified Lattice Based Adaptive IIR Notch Filter

    National Research Council Canada - National Science Library

    Dhillon, Santpal

    2001-01-01

    ...) notch filter with a simplified adaptation algorithm for removal of power line frequency from ECG signals, The performance of this filter is better as compared to a second order infinite impulse response (IIR...

  3. CODE STEM - Moon, Mars, and Beyond; DLESE-Powered On-Line Classroom, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — "CODE (COrps DEvelopment) STEM (Science, Technology, Engineering, and Math) ? Moon Mars and Beyond; DLESE-Powered On-Line Classroom" shares the excitement of...

  4. Possible mechanisms by which electric fields from power lines might affect airborne particles harmful to health

    International Nuclear Information System (INIS)

    Swanson, J.; Jeffers, D.

    1999-01-01

    Power lines produce alternating electric fields and modify static electric fields in their vicinity. These electric fields, if large enough, can alter the concentration or transport of airborne particles (including particles harmful to health), for example by causing deposition of charged particles, polarisation of neutral particles, or by production of ions. It has been suggested that this could lead to adverse health effects being associated with power lines. Theoretical considerations and experimental evidence relevant to eight separate postulated mechanisms involving power lines and airborne particles are examined. On theoretical grounds, none should lead to any adverse health effect, primarily because the effects produced are very small and are swamped by air currents or by gravity, and because people spend limited time in the relevant conditions. The experimental evidence also weighs against any adverse health effects. Further, even if significant health effects were produced, they would be different from those suggested by existing epidemiology concerning power lines. (author)

  5. A Multilayer Perceptron-Based Impulsive Noise Detector with Application to Power-Line-Based Sensor Networks

    KAUST Repository

    Chien, Ying-Ren; Chen, Jie-Wei; Xu, Sendren Sheng-Dong

    2018-01-01

    For power-line-based sensor networks, impulsive noise (IN) will dramatically degrade the data transmission rate in the power line. In this paper, we present a multilayer perceptron (MLP)-based approach to detect IN in orthogonal frequency

  6. MATHEMATICAL MODEL OF POWER CONSUMPTION FOR SOME OIL PIPE-LINE SECTIONS WITH POOR OPERATIONAL STABILITY

    Directory of Open Access Journals (Sweden)

    J. N. Kolesnik

    2005-01-01

    Full Text Available Mathematical model of power consumption for technologically completed and non-completed oil pipe-line sections with poor operational stability has been developed on the basis of daily indices concerning oil transportation regimes. The model permits to take into account tendencies in power consumption under various time prediction cycles and ranges of oil freight turnover, changes in the bulk and characteristics of the transported oil, configuration and design parameters of oil pipe-line.

  7. A modular restoration tower for electric power line transmission

    Energy Technology Data Exchange (ETDEWEB)

    Nicolazzi, L.C.; Pereira, J.C.; Leonel, C.E.L.; Rocha, G.B.; Bianchezzi, V.; Mendes, F. [Universidade Federal Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica], Emails: lauro@grante.ufsc.br, jcarlos@grante.ufsc.br; Luz, R.L. [ELETROSUL Centrais Eletricas S.A., Florianopolis, SC (Brazil)], Email: rluz@eletrosul.gov.br

    2009-07-01

    The main target of this R and D project is to develop an restoration tower for electric energy lines transmission. Whereas these towers should present the main features like transport facility, easiest assembling associated with a low cost of manufacture, it was applied the single-column tower concepts supported by stays, modularized, framed and articulated at the base. The concepts used for this development was a design methodology. From the different definition situations of load, numerical models have been developed focusing the design to the best of structural element arrangements of its modules. Then, tests were performed in laboratory to determine the module structural performance for different work load situations. These tests served to identify inconsistencies in the numerical models and proposed adjustments in its design to improve its performance on the strength and stability. (author)

  8. Simple Activities for Powerful Impact

    Science.gov (United States)

    LaConte, K.; Shupla, C. B.; Dusenbery, P.; Harold, J. B.; Holland, A.

    2016-12-01

    STEM education is having a transformational impact on libraries across the country. The STAR Library Education Network (STAR_Net) provides free Science-Technology Activities & Resources that are helping libraries to engage their communities in STEM learning experiences. Hear the results of a national 2015 survey of library and STEM professionals and learn what STEM programming is currently in place in public libraries and how libraries approach and implement STEM programs. Experience hands-on space science activities that are being used in library programs with multiple age groups. Through these hands-on activities, learners explore the nature of science and employ science and engineering practices, including developing and using models, planning and carrying out investigations, and engaging in argument from evidence (NGSS Lead States, 2013). Learn how STAR_Net can help you print (free!) mini-exhibits and educator guides. Join STAR_Net's online community and access STEM resources and webinars to work with libraries in your local community.

  9. Multi-Mode Operation for On-line Uninterruptible Power Supply System

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Golestan, Saeed

    2018-01-01

    To enhance the robustness and disturbance rejection ability of an on-line uninterruptible power supply (UPS) system, an Internal Model Control (IMC)-based DC-link voltage regulation method is proposed in this paper. Furthermore, the multi-mode operations of the on-line UPS system are investigated...

  10. Detection of the power lines in UAV remote sensed images using spectral-spatial methods.

    Science.gov (United States)

    Bhola, Rishav; Krishna, Nandigam Hari; Ramesh, K N; Senthilnath, J; Anand, Gautham

    2018-01-15

    In this paper, detection of the power lines on images acquired by Unmanned Aerial Vehicle (UAV) based remote sensing is carried out using spectral-spatial methods. Spectral clustering was performed using Kmeans and Expectation Maximization (EM) algorithm to classify the pixels into the power lines and non-power lines. The spectral clustering methods used in this study are parametric in nature, to automate the number of clusters Davies-Bouldin index (DBI) is used. The UAV remote sensed image is clustered into the number of clusters determined by DBI. The k clustered image is merged into 2 clusters (power lines and non-power lines). Further, spatial segmentation was performed using morphological and geometric operations, to eliminate the non-power line regions. In this study, UAV images acquired at different altitudes and angles were analyzed to validate the robustness of the proposed method. It was observed that the EM with spatial segmentation (EM-Seg) performed better than the Kmeans with spatial segmentation (Kmeans-Seg) on most of the UAV images. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Proceedings of the 9. international symposium on power-line communications and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Lampe, L. (comp.) [British Columbia Univ., Vancouver, BC (Canada). Dept. of Electrical and Computer Engineering

    2005-07-01

    The 2005 International Symposium on Power Line Communications and Its Applications (ISPLC 2005) is the leading international scientific conference on technology and applications for communication over power lines. The conference addresses the latest technological advances in power-line communications and current and future applications of power-line communication systems including broadband Internet access, indoor home networking, power-line based communications in vehicles, power-line control networks, and automatic meter reading systems. Specific conference papers included measurements, channel characterization and modeling; standards and regulations; electromagnetic compatibility; information and communication theory; modulation and error-control coding techniques; single carrier, OFDM, and spread spectrum techniques; detection, estimation, and iterative processing techniques; signal processing algorithms and devices; multiple-access techniques; modem and LSI design; networks and protocols; system architectures; automatic meter reading systems; applications and services; and, experimental systems and field trials. A total of 90 papers were featured and organized into 14 regular sessions and one poster session. Seven of these presentations have been catalogued separately for inclusion in this database. In addition to the technical program, 3 keynotes speeches and 2 panel discussions were presented and chaired by distinguished speakers and moderators. tabs., figs.

  12. Electric Power Lines : Questions and Answers on Research into Health Effects.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1993-11-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this pamphlet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. (BPA is the Pacific Northwest`s Federal electric power marketing agency.) First, some basic electrical terms are defined, and electric and magnetic fields are described. Next, answers are given to several questions about recent scientific studies. We then describe how BPA is addressing public concerns raised by these studies. Some important information about electrical safety follows. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this pamphlet.

  13. CO Spectral Line Energy Distributions of Infrared-Luminous Galaxies and Active Galactic Nuclei

    Science.gov (United States)

    Papadopoulos, Padeli P.; van der Werf, Paul; Isaak, Kate; Xilouris, Emmanuel M.

    2010-06-01

    We report on new sensitive CO J = 6-5 line observations of several luminous infrared galaxies (LIRGs; L IR(8-1000 μm) >~ 1011 L sun), 36% (8/22) of them ultraluminous infrared galaxies (ULIRGs) (L IR>1012 L sun), and two powerful local active galactic nuclei (AGNs)—the optically luminous QSO PG 1119+120 and the powerful radio galaxy 3C 293—using the James Clerk Maxwell Telescope on Mauna Kea in Hawaii. We combine these observations with existing low-J CO data and dust emission spectral energy distributions in the far-infrared-submillimeter from the literature to constrain the properties of the star-forming interstellar medium (ISM) in these systems. We then build the first local CO spectral line energy distributions (SLEDs) for the global molecular gas reservoirs that reach up to high J-levels. These CO SLEDs are neither biased by strong lensing (which affects many of those constructed for high-redshift galaxies), nor suffer from undersampling of CO-bright regions (as most current high-J CO observations of nearby extended systems do). We find: (1) a significant influence of dust optical depths on the high-J CO lines, suppressing the J = 6-5 line emission in some of the most IR-luminous LIRGs, (2) low global CO line excitation possible even in vigorously star-forming systems, (3) the first case of a shock-powered high-excitation CO SLED in the radio galaxy 3C 293 where a powerful jet-ISM interaction occurs, and (4) unusually highly excitated gas in the optically powerful QSO PG 1119+120. In Arp 220 and possibly other (U)LIRGs very faint CO J = 6-5 lines can be attributed to significant dust optical depths at short submillimeter wavelengths immersing those lines in a strong dust continuum, and also causing the C+ line luminosity deficit often observed in such extreme starbursts. Re-analysis of the CO line ratios available for submillimeter galaxies suggests that similar dust opacities also may be present in these high-redshift starbursts, with genuinely low

  14. CO SPECTRAL LINE ENERGY DISTRIBUTIONS OF INFRARED-LUMINOUS GALAXIES AND ACTIVE GALACTIC NUCLEI

    International Nuclear Information System (INIS)

    Papadopoulos, Padeli P.; Van der Werf, Paul; Isaak, Kate; Xilouris, Emmanuel M.

    2010-01-01

    We report on new sensitive CO J = 6-5 line observations of several luminous infrared galaxies (LIRGs; L IR (8-1000 μm) ∼> 10 11 L sun ), 36% (8/22) of them ultraluminous infrared galaxies (ULIRGs) (L IR >10 12 L sun ), and two powerful local active galactic nuclei (AGNs)-the optically luminous QSO PG 1119+120 and the powerful radio galaxy 3C 293-using the James Clerk Maxwell Telescope on Mauna Kea in Hawaii. We combine these observations with existing low-J CO data and dust emission spectral energy distributions in the far-infrared-submillimeter from the literature to constrain the properties of the star-forming interstellar medium (ISM) in these systems. We then build the first local CO spectral line energy distributions (SLEDs) for the global molecular gas reservoirs that reach up to high J-levels. These CO SLEDs are neither biased by strong lensing (which affects many of those constructed for high-redshift galaxies), nor suffer from undersampling of CO-bright regions (as most current high-J CO observations of nearby extended systems do). We find: (1) a significant influence of dust optical depths on the high-J CO lines, suppressing the J = 6-5 line emission in some of the most IR-luminous LIRGs, (2) low global CO line excitation possible even in vigorously star-forming systems, (3) the first case of a shock-powered high-excitation CO SLED in the radio galaxy 3C 293 where a powerful jet-ISM interaction occurs, and (4) unusually highly excitated gas in the optically powerful QSO PG 1119+120. In Arp 220 and possibly other (U)LIRGs very faint CO J = 6-5 lines can be attributed to significant dust optical depths at short submillimeter wavelengths immersing those lines in a strong dust continuum, and also causing the C + line luminosity deficit often observed in such extreme starbursts. Re-analysis of the CO line ratios available for submillimeter galaxies suggests that similar dust opacities also may be present in these high-redshift starbursts, with genuinely low

  15. ''High-power microwave'' tubes: In the laboratory and on-line

    International Nuclear Information System (INIS)

    Caryotakis, G.

    1994-01-01

    The possibility of incapacitating the electronic circuits of hostile equipment with high-energy microwave pulses has created a demand for microwave tubes capable of very high peak pulsed powers. Experimentalists, primarily from the plasma physics community, have been working in this field, dubbed High-Power Microwave or HPM. Separately, research in high-energy physics requires electron-positron colliders with energies approaching 1 trillion electron-volts (1 terra-electron-volt, or TeV). Such accelerators must be powered by microwave sources that are very similar to some that are proposed for the HPM application. The paper points out that for these tubes to be used on-line in the manner intended, they must be designed and built to operate at a very high internal vacuum, which is not the case for many of the HPM laboratory projects. The development of a particular klystron at the Stanford Linear Accelerator Center is described in detail in order to illustrate the need for special facilities and strong Quality Control. Should the Defense requirements for HPM survive the end of the cold war, an effort should be made to coordinate the tube development activities serving these two widely disparate applications

  16. Facts and feelings : Framing effects in responses to uncertainties about high-voltage power lines

    NARCIS (Netherlands)

    de Vries, G.; de Bruijn, J.A.

    2017-01-01

    To ensure power supply security, electricity transmission system operators (TSOs) have to upscale high-voltage overhead power lines. However, upscaling frequently meets opposition. Opposition can be caused by uncertainties about risks and benefits and might lead to costly delays (Linder, 1995;

  17. Lightning current distribution to ground at a power line tower carrying a radio base station

    NARCIS (Netherlands)

    Grcev, L.; Deursen, van A.P.J.; Waes, van J.B.M.

    2005-01-01

    Radio base stations are often mounted on towers of power transmission lines. They are usually powered from the low-voltage network through an isolating transformer, to separate the high- and low-voltage networks. The isolating transformer ensures security at customers' premises in the case of nearby

  18. Fuji Electric`s line of uninterruptible power systems; Muteiden dengen sochi no seihin keiretsu

    Energy Technology Data Exchange (ETDEWEB)

    Kobata, S.; Ishikawa, Y.; Yokoyama, T. [Fuji Electric Co. Ltd., Tokyo (Japan)

    1997-08-10

    Uninterruptible power systems (UPSs) are widely used in financial institutions, utility services, totalizator systems, traffic control systems, plants, new media, medical systems, and information processing services. These are highly reliable power supply systems to protect computer-aided information and communication systems from power failure or defects. Described herein is the company`s line of UPSs developed by integrating power electronics, and digital and high-frequency switching techniques. The major components of a UPS are rectifier, inverter and battery. Power is supplied by commercial or inverter system. The former is widely used by plants because of its low loss and high efficiency, although distorted output waves or instantaneous power failure may occur when the power source is switched in the case of power failure. The latter is suited for computer systems, because of its ability of stably supplying power, without being affected by the disturbances which may occur in the commercial system. 7 figs., 2 tabs.

  19. Implementation of the frequency dependent line model in a real-time power system simulator

    Directory of Open Access Journals (Sweden)

    Reynaldo Iracheta-Cortez

    2017-09-01

    Full Text Available In this paper is described the implementation of the frequency-dependent line model (FD-Line in a real-time digital power system simulator. The main goal with such development is to describe a general procedure to incorporate new realistic models of power system components in modern real-time simulators based on the Electromagnetic Transients Program (EMTP. In this procedure are described, firstly, the steps to obtain the time domain solution of the differential equations that models the electromagnetic behavior in multi-phase transmission lines with frequency dependent parameters. After, the algorithmic solution of the FD-Line model is implemented in Simulink environment, through an S-function programmed in C language, for running off-line simulations of electromagnetic transients. This implementation allows the free assembling of the FD Line model with any element of the Power System Blockset library and also, it can be used to build any network topology. The main advantage of having a power network built in Simulink is that can be executed in real-time by means of the commercial eMEGAsim simulator. Finally, several simulation cases are presented to validate the accuracy and the real-time performance of the FD-Line model.

  20. Transmission Characteristics of an OFDM signal for Power Line Communication System with High Bit Rate

    Science.gov (United States)

    Mori, Akira; Watanabe, Yosuke; Tokuda, Masamitsu; Kawamoto, Koji

    In this paper, we measured what influence the sinusoidal transmission characteristics of the electric power line with various forms gave to the transmission characteristic of OFDM (Orthogonal Frequency Division Multiplexing) signal through PLC (power line communication system) modem. We classified the electric power line transmission line with various forms in a real environment into two basic elements, which are an outlet type branch and a switch type branch. Next, PHY rate (Physical rate) is measured for each basic element connected with the PLC modem. At this time, the transmission characteristics of the electric power line are simulated from measured data. OFDM sending and receiving systems are composed on the computer, and the PHY rate is simulated. By comparing with measured and calculated values, it is revealed that PHY rate of PLC modem is most affected in the case of the power line transmission characteristics having broad band and high level attenuation and group delay variation, and is not affected in the case of that having narrow band attenuation and group delay variation.

  1. Airborne LIDAR Power Line Classification Based on Spatial Topological Structure Characteristics

    Science.gov (United States)

    Wang, Y.; Chen, Q.; Li, K.; Zheng, D.; Fang, J.

    2017-09-01

    Automatic extraction of power lines has become a topic of great importance in airborne LiDAR data processing for transmission line management. In this paper, we present a new, fully automated and versatile framework that consists of four steps: (i) power line candidate point filtering, (ii) neighbourhood selection, (iii) feature extraction based on spatial topology, and (iv) SVM classification. In a detailed evaluation involving seven neighbourhood definitions, 26 geometric features and two datasets, we demonstrated that the use of multi-scale neighbourhoods for individual 3D points significantly improved the power line classification. Additionally, we showed that the spatial topological features may even further improve the results while reducing data processing time.

  2. Radiological Assessment for the Removal of Legacy BPA Power Lines that Cross the Hanford Site

    International Nuclear Information System (INIS)

    Millsap, William J.; Brush, Daniel J.

    2013-01-01

    This paper discusses some radiological field monitoring and assessment methods used to assess the components of an old electrical power transmission line that ran across the Hanford Site between the production reactors area (100 Area) and the chemical processing area (200 Area). This task was complicated by the presence of radon daughters -- both beta and alpha emitters -- residing on the surfaces, particularly on the surfaces of weathered metals and metals that had been electrically-charged. In many cases, these activities were high compared to the DOE Surface Contamination Guidelines, which were used as guides for the assessment. These methods included the use of the Toulmin model of argument, represented using Toulmin diagrams, to represent the combined force of several strands of evidences, rather than a single measurement of activity, to demonstrate beyond a reasonable doubt that no or very little Hanford activity was present and mixed with the natural activity. A number of forms of evidence were used: the overall chance of Hanford contamination; measurements of removable activity, beta and alpha; 1-minute scaler counts of total surface activity, beta and alpha, using 'background makers'; the beta activity to alpha activity ratios; measured contamination on nearby components; NaI gamma spectral measurements to compare uncontaminated and potentially-contaminated spectra, as well as measurements for the sentinel radionuclides, Am- 241 and Cs-137 on conducting wire; comparative statistical analyses; and in-situ measurements of alpha spectra on conducting wire showing that the alpha activity was natural Po-210, as well as to compare uncontaminated and potentially-contaminated spectra

  3. Radiological Assessment for the Removal of Legacy BPA Power Lines that Cross the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Millsap, William J.; Brush, Daniel J.

    2013-11-13

    This paper discusses some radiological field monitoring and assessment methods used to assess the components of an old electrical power transmission line that ran across the Hanford Site between the production reactors area (100 Area) and the chemical processing area (200 Area). This task was complicated by the presence of radon daughters -- both beta and alpha emitters -- residing on the surfaces, particularly on the surfaces of weathered metals and metals that had been electrically-charged. In many cases, these activities were high compared to the DOE Surface Contamination Guidelines, which were used as guides for the assessment. These methods included the use of the Toulmin model of argument, represented using Toulmin diagrams, to represent the combined force of several strands of evidences, rather than a single measurement of activity, to demonstrate beyond a reasonable doubt that no or very little Hanford activity was present and mixed with the natural activity. A number of forms of evidence were used: the overall chance of Hanford contamination; measurements of removable activity, beta and alpha; 1-minute scaler counts of total surface activity, beta and alpha, using "background makers"; the beta activity to alpha activity ratios; measured contamination on nearby components; NaI gamma spectral measurements to compare uncontaminated and potentially-contaminated spectra, as well as measurements for the sentinel radionuclides, Am- 241 and Cs-137 on conducting wire; comparative statistical analyses; and in-situ measurements of alpha spectra on conducting wire showing that the alpha activity was natural Po-210, as well as to compare uncontaminated and potentially-contaminated spectra.

  4. Power lines, roads, and avian nest survival: effects on predator identity and predation intensity.

    Science.gov (United States)

    DeGregorio, Brett A; Weatherhead, Patrick J; Sperry, Jinelle H

    2014-05-01

    1 Anthropogenic alteration of landscapes can affect avian nest success by influencing the abundance, distribution, and behavior of predators. Understanding avian nest predation risk necessitates understanding how landscapes affect predator distribution and behavior. 2 From a sample of 463 nests of 17 songbird species, we evaluated how landscape features (distance to forest edge, unpaved roads, and power lines) influenced daily nest survival. We also used video cameras to identify nest predators at 137 nest predation events and evaluated how landscape features influenced predator identity. Finally, we determined the abundance and distribution of several of the principal predators using surveys and radiotelemetry. 3 Distance to power lines was the best predictor of predator identity: predation by brown-headed cowbirds (Molothrus ater), corvids (Corvus sp. and Cyanocitta cristata), racers (Coluber constrictor), and coachwhips (Masticophis flagellum) increased with proximity to power lines, whereas predation by rat snakes (Elaphe obsoleta) and raptors decreased. In some cases, predator density may reliably indicate nest predation risk because racers, corvids, and cowbirds frequently used power line right-of-ways. 4 Of five bird species with enough nests to analyze individually, daily nest survival of only indigo buntings (Passerina cyanea) decreased with proximity to power lines, despite predation by most predators at our site being positively associated with power lines. For all nesting species combined, distance to unpaved road was the model that most influenced daily nest survival. This pattern is likely a consequence of rat snakes, the locally dominant nest predator (28% of predation events), rarely using power lines and associated areas. Instead, rat snakes were frequently associated with road edges, indicating that not all edges are functionally similar. 5 Our results suggest that interactions between predators and landscape features are likely to be specific to

  5. Effect of Tower Shadow and Wind Shear in a Wind Farm on AC Tie-Line Power Oscillations of Interconnected Power Systems

    DEFF Research Database (Denmark)

    Tan, Jin; Hu, Weihao; Wang, Xiaoru

    2013-01-01

    This paper describes a frequency domain approach for evaluating the impact of tower shadow and wind shear effects (TSWS) on tie-line power oscillations. A simplified frequency domain model of an interconnected power system with a wind farm is developed. The transfer function, which relates the tie......-line power variation to the mechanical power variation of a wind turbine, and the expression of the maximum magnitude of tie-line power oscillations are derived to identify the resonant condition and evaluate the potential risk. The effects of the parameters on the resonant magnitude of the tie-line power...... are also discussed. The frequency domain analysis reveals that TSWS can excite large tie-line power oscillations if the frequency of TSWS approaches the tie-line resonant frequency, especially in the case that the wind farm is integrated into a relatively small grid and the tie-line of the interconnected...

  6. Study for reactive power on distribution system line B RSG-GAS

    International Nuclear Information System (INIS)

    Yan Bony Marsahala

    2010-01-01

    Study for reactive power on distribution system line B RSG-GA is already done. The study intended to evaluate how much inductive load need the reactive power (positive), how much power factor, and what will be done to increase the power factor. The reactive power is the losses power, can't be changed into energy, but it is need for transmission process and it is cause the energy losses. The loads on distribution system line B consist of induction motors which are used for primary cooling system and secondary cooling system, lift, blower on cooling tower, and air condition system. Due to the motors using, the power factor are falling down to low. By the calculation results give that the inductive loads on distribution line B are 850 KVA and these loads caused the low power factor 0.80. If we want to increase the power factor up to 0.95, it is need to install the reactive loads likes capacitor bank 250 KVAR. (author)

  7. Reverberation Mapping of Optical Emission Lines in Five Active Galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Fausnaugh, M. M.; Denney, K. D.; Peterson, B. M.; Kochanek, C. S.; Pogge, R. W.; Brown, Jonathan S.; Coker, C. T. [Department of Astronomy, The Ohio State University, 140 W. 18th Avenue, Columbus, OH 43210 (United States); Grier, C. J.; Beatty, Thomas G. [Department of Astronomy and Astrophysics, The Pennsylvania State University, 525 Davey Laboratory, University Park, PA 16802 (United States); Bentz, M. C. [Department of Physics and Astronomy, Georgia State University, Atlanta, GA 30303 (United States); Rosa, G. De [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Adams, S. M. [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Barth, A. J. [Department of Physics and Astronomy, 4129 Frederick Reines Hall, University of California, Irvine, CA 92697 (United States); Bhattacharjee, A.; Brotherton, M. S. [Department of Physics and Astronomy, University of Wyoming, 1000 E. University Avenue, Laramie, WY (United States); Borman, G. A. [Crimean Astrophysical Observatory, P/O Nauchny, Crimea 298409 (Russian Federation); Boroson, T. A. [Las Cumbres Global Telescope Network, 6740 Cortona Drive, Suite 102, Santa Barbara, CA 93117 (United States); Bottorff, M. C. [Fountainwood Observatory, Department of Physics FJS 149, Southwestern University, 1011 E. University Avenue, Georgetown, TX 78626 (United States); Brown, Jacob E. [Department of Physics and Astronomy, University of Missouri, Columbia (United States); Crawford, S. M. [South African Astronomical Observatory, P.O. Box 9, Observatory 7935, Cape Town (South Africa); and others

    2017-05-10

    We present the first results from an optical reverberation mapping campaign executed in 2014 targeting the active galactic nuclei (AGNs) MCG+08-11-011, NGC 2617, NGC 4051, 3C 382, and Mrk 374. Our targets have diverse and interesting observational properties, including a “changing look” AGN and a broad-line radio galaxy. Based on continuum-H β lags, we measure black hole masses for all five targets. We also obtain H γ and He ii λ 4686 lags for all objects except 3C 382. The He ii λ 4686 lags indicate radial stratification of the BLR, and the masses derived from different emission lines are in general agreement. The relative responsivities of these lines are also in qualitative agreement with photoionization models. These spectra have extremely high signal-to-noise ratios (100–300 per pixel) and there are excellent prospects for obtaining velocity-resolved reverberation signatures.

  8. Reverberation Mapping of Optical Emission Lines in Five Active Galaxies

    International Nuclear Information System (INIS)

    Fausnaugh, M. M.; Denney, K. D.; Peterson, B. M.; Kochanek, C. S.; Pogge, R. W.; Brown, Jonathan S.; Coker, C. T.; Grier, C. J.; Beatty, Thomas G.; Bentz, M. C.; Rosa, G. De; Adams, S. M.; Barth, A. J.; Bhattacharjee, A.; Brotherton, M. S.; Borman, G. A.; Boroson, T. A.; Bottorff, M. C.; Brown, Jacob E.; Crawford, S. M.

    2017-01-01

    We present the first results from an optical reverberation mapping campaign executed in 2014 targeting the active galactic nuclei (AGNs) MCG+08-11-011, NGC 2617, NGC 4051, 3C 382, and Mrk 374. Our targets have diverse and interesting observational properties, including a “changing look” AGN and a broad-line radio galaxy. Based on continuum-H β lags, we measure black hole masses for all five targets. We also obtain H γ and He ii λ 4686 lags for all objects except 3C 382. The He ii λ 4686 lags indicate radial stratification of the BLR, and the masses derived from different emission lines are in general agreement. The relative responsivities of these lines are also in qualitative agreement with photoionization models. These spectra have extremely high signal-to-noise ratios (100–300 per pixel) and there are excellent prospects for obtaining velocity-resolved reverberation signatures.

  9. K-Line Patterns’ Predictive Power Analysis Using the Methods of Similarity Match and Clustering

    Directory of Open Access Journals (Sweden)

    Lv Tao

    2017-01-01

    Full Text Available Stock price prediction based on K-line patterns is the essence of candlestick technical analysis. However, there are some disputes on whether the K-line patterns have predictive power in academia. To help resolve the debate, this paper uses the data mining methods of pattern recognition, pattern clustering, and pattern knowledge mining to research the predictive power of K-line patterns. The similarity match model and nearest neighbor-clustering algorithm are proposed for solving the problem of similarity match and clustering of K-line series, respectively. The experiment includes testing the predictive power of the Three Inside Up pattern and Three Inside Down pattern with the testing dataset of the K-line series data of Shanghai 180 index component stocks over the latest 10 years. Experimental results show that (1 the predictive power of a pattern varies a great deal for different shapes and (2 each of the existing K-line patterns requires further classification based on the shape feature for improving the prediction performance.

  10. Development of a new MT system using the commercial power line as a source (Part 3)

    Energy Technology Data Exchange (ETDEWEB)

    Tsubota, Koji; Noritake, Kazumitsu; Miyata, Hatsuho; Sakuma, Hideki; Saito, Akira

    1988-10-01

    PLMT method is an electromagnetic induction method which uses a commercial power line as a source of electomagnetic energy, and enables accurate measurement in short periods. A numeric calculation example of the effect of distance from a power line as well as the results of actual measurements carried out in the Sekiret mining area (Niger) and Kushikino area, Kagoshima Prefecture are reported. Possibility of estimating average ground resistivity by numerical calculation is demonstrated using the electric field and magnetic field generated by power lines. In the measurement in the Sekiret mining area, Niger, north-south electric field and east-west magnetic field were measured from directly under the power line to the distance of 20 km. The relation of the amplitudes of electric field and magnetic field with the distance is shown. The theoretic curve of 0.02 (mho/m) conductivity agreed well with the value mesured in the area about 1 km from the power line. In the measurement at Kushikino area, the value agrees well with the theoretical curve of 0.01 conductivity, whose average resistivity is considered to be about 100 {Omega}m. 6 references, 11 figures.

  11. A Measurement and Power Line Communication System Design for Renewable Smart Grids

    Science.gov (United States)

    Kabalci, E.; Kabalci, Y.

    2013-10-01

    The data communication over the electric power lines can be managed easily and economically since the grid connections are already spread around all over the world. This paper investigates the applicability of Power Line Communication (PLC) in an energy generation system that is based on photovoltaic (PV) panels with the modeling study in Matlab/Simulink. The Simulink model covers the designed PV panels, boost converter with Perturb and Observe (P&O) control algorithm, full bridge inverter, and the binary phase shift keying (BPSK) modem that is utilized to transfer the measured data over the power lines. This study proposes a novel method to use the electrical power lines not only for carrying the line voltage but also to transmit the measurements of the renewable energy generation plants. Hence, it is aimed at minimizing the additional monitoring costs such as SCADA, Ethernet-based or GSM based systems by using the proposed technique. Although this study is performed with solar power plants, the proposed model can be applied to other renewable generation systems. Consequently, the usage of the proposed technique instead of SCADA or Ethernet-based systems eliminates additional monitoring costs.

  12. Optimization Design of an Inductive Energy Harvesting Device for Wireless Power Supply System Overhead High-Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-03-01

    Full Text Available Overhead high voltage power line (HVPL online monitoring equipment is playing an increasingly important role in smart grids, but the power supply is an obstacle to such systems’ stable and safe operation, so in this work a hybrid wireless power supply system, integrated with inductive energy harvesting and wireless power transmitting, is proposed. The energy harvesting device extracts energy from the HVPL and transfers that from the power line to monitoring equipment on transmission towers by transmitting and receiving coils, which are in a magnetically coupled resonant configuration. In this paper, the optimization design of online energy harvesting devices is analyzed emphatically by taking both HVPL insulation distance and wireless power supply efficiency into account. It is found that essential parameters contributing to more extracted energy include large core inner radius, core radial thickness, core height and small core gap within the threshold constraints. In addition, there is an optimal secondary coil turn that can maximize extracted energy when other parameters remain fixed. A simple and flexible control strategy is then introduced to limit power fluctuations caused by current variations. The optimization methods are finally verified experimentally.

  13. Active Power Measurement Based on Multiwavelet Transforms

    Directory of Open Access Journals (Sweden)

    Xiao-Bing Zhang

    2014-01-01

    Full Text Available This paper discusses a new method for calculating active power in the multiwavelet domain. When the voltage and current waveforms are analyzed using multiwavelet, the active power can be calculated by simply adding the products of the multiwavelet coefficients without having to reconstruct the signals back to the time domain first and then using the traditional integration. From the simulation result, we can see that the results using multiwavelet are better than the ones using wavelet and Fourier Transforms no matter which prefilter is used.

  14. Electric Power Lines : Questions and Answers on Research into Health Effects.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1995-06-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the EMF (electric and magnetic fields) produced by power lines and other electrical devices affect our health. Although no adverse health effects of electric power EMF have been confirmed, there is continued scientific uncertainty about this issue. Research on EMF is ongoing throughout the world. The purpose of this booklet is to answer some common questions that the BPA (Bonneville Power Administration) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

  15. Noise Sources, Effects and Countermeasures in Narrowband Power-Line Communications Networks: A Practical Approach

    Directory of Open Access Journals (Sweden)

    Gregorio López

    2017-08-01

    Full Text Available The integration of Distributed Generation, Electric Vehicles, and storage without compromising the quality of the power delivery requires the deployment of a communications overlay that allows monitoring and controlling low voltage networks in almost real time. Power Line Communications are gaining momentum for this purpose since they present a great trade-off between economic and technical features. However, the power lines also represent a harsh communications medium which presents different problems such as noise, which is indeed affected by Distributed Generation, Electric Vehicles, and storage. This paper provides a comprehensive overview of the types of noise that affects Narrowband Power Line Communications, including normative noises, noises coming from common electronic devices measured in actual operational power distribution networks, and noises coming from photovoltaic inverters and electric vehicle charging spots measured in a controlled environment. The paper also reviews several techniques to mitigate the effects of noise, paying special attention to passive filtering, as for being one of the most widely used solution to avoid this kind of problems in the field. In addition, the paper presents a set of tests carried out to evaluate the impact of some representative noises on Narrowband Power Line Communications network performance, as well as the effectiveness of different passive filter configurations to mitigate such an impact. In addition, the considered sources of noise can also bring value to further improve PLC communications in the new scenarios of the Smart Grid as an input to theoretical models or simulations.

  16. Resilience of electricity grids against transmission line overloads under wind power injection at different nodes.

    Science.gov (United States)

    Schiel, Christoph; Lind, Pedro G; Maass, Philipp

    2017-09-14

    A steadily increasing fraction of renewable energy sources for electricity production requires a better understanding of how stochastic power generation affects the stability of electricity grids. Here, we assess the resilience of an IEEE test grid against single transmission line overloads under wind power injection based on the dc power flow equations and a quasi-static grid response to wind fluctuations. Thereby we focus on the mutual influence of wind power generation at different nodes. We find that overload probabilities vary strongly between different pairs of nodes and become highly affected by spatial correlations of wind fluctuations. An unexpected behaviour is uncovered: for a large number of node pairs, increasing wind power injection at one node can increase the power threshold at the other node with respect to line overloads in the grid. We find that this seemingly paradoxical behaviour is related to the topological distance of the overloaded line from the shortest path connecting the wind nodes. In the considered test grid, it occurs for all node pairs, where the overloaded line belongs to the shortest path.

  17. On-line test of power distribution prediction system for boiling water reactors

    International Nuclear Information System (INIS)

    Nishizawa, Y.; Kiguchi, T.; Kobayashi, S.; Takumi, K.; Tanaka, H.; Tsutsumi, R.; Yokomi, M.

    1982-01-01

    A power distribution prediction system for boiling water reactors has been developed and its on-line performance test has proceeded at an operating commercial reactor. This system predicts the power distribution or thermal margin in advance of control rod operations and core flow rate change. This system consists of an on-line computer system, an operator's console with a color cathode-ray tube, and plant data input devices. The main functions of this system are present power distribution monitoring, power distribution prediction, and power-up trajectory prediction. The calculation method is based on a simplified nuclear thermal-hydraulic calculation, which is combined with a method of model identification to the actual reactor core state. It has been ascertained by the on-line test that the predicted power distribution (readings of traversing in-core probe) agrees with the measured data within 6% root-mean-square. The computing time required for one prediction calculation step is less than or equal to 1.5 min by an HIDIC-80 on-line computer

  18. The Power Quality Compensation Strategy for Power Distribution System Based on Hybrid Parallel Active Power Filters

    Directory of Open Access Journals (Sweden)

    Rachid DEHINI

    2010-12-01

    Full Text Available In this paper, the main aim is to confront the performance of shunt active power filter (SAPF and the shunt hybrid active power filter (SHAPF to achieve flexibility and reliability of the filter devices. Both of the two devices used the classical proportional-integral controller for pulse generation to trigger the inventers MOSFET’s. In the adopted hybrid active filter there is a passive power filter with high power rating to filter the low order harmonies and one active filter with low power rating to filter the other high order harmonies. In order to investigate the effectiveness of (SHAPF, the studies have been accomplished using simulation with the MATLAB-SIMULINK. The results show That (SHAPF is more effective than (SAPF, and has lower cost.

  19. Kertész line of thermally activated breakdown phenomena

    KAUST Repository

    Yoshioka, Naoki

    2010-11-12

    Based on a fiber bundle model we substantially extend the phase-transition analogy of thermally activated breakdown of homogeneous materials. We show that the competition of breaking due to stress enhancement and due to thermal fluctuations leads to an astonishing complexity of the phase space of the system: varying the load and the temperature a phase boundary emerges, separating a Griffith-type regime of abrupt failure analogous to first-order phase transitions from disorder dominated fracture where a spanning cluster of cracks emerges. We demonstrate that the phase boundary is the Kertész line of the system along which thermally activated fracture appears as a continuous phase transition analogous to percolation. The Kertész line has technological relevance setting the boundary of safe operation for construction components under high thermal loads. © 2010 The American Physical Society.

  20. APOBEC3DE Inhibits LINE-1 Retrotransposition by Interacting with ORF1p and Influencing LINE Reverse Transcriptase Activity.

    Directory of Open Access Journals (Sweden)

    Weizi Liang

    Full Text Available Human long interspersed elements 1 (LINE-1 or L1 is the only autonomous non-LTR retroelement in humans and has been associated with genome instability, inherited genetic diseases, and the development of cancer. Certain human APOBEC3 family proteins are known to have LINE-1 restriction activity. The mechanisms by which APOBEC3 affects LINE-1 retrotransposition are not all well characterized; here, we confirm that both A3B and A3DE have a strong ability to inhibit LINE-1 retrotransposition. A3DE interacts with LINE-1 ORF1p to target LINE-1 ribonucleoprotein particles in an RNA-dependent manner. Moreover, A3DE binds to LINE-1 RNA and ORF1 protein in cell culture system. Fluorescence microscopy demonstrated that A3DE co-localizes with ORF1p in cytoplasm. Furthermore, A3DE inhibits LINE-1 reverse transcriptase activity in LINE-1 ribonucleoprotein particles in a cytidine deaminase-independent manner. In contrast, A3B has less inhibitory effects on LINE-1 reverse transcriptase activity despite its strong inhibition of LINE-1 retrotransposition. This study demonstrates that different A3 proteins have been evolved to inhibit LINE-1 activity through distinct mechanisms.

  1. Strain change and creep behavior of STACIR/AW power line with heat exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Park, S.D.; Kim, S.S.; Lee, H.W. [Overhead Conductor Research Lab., Korea Electrotechnology Research Inst., Changwon (Korea)

    2005-07-01

    As a way to expand electric capacity in power line with hovering of electric power demand, STACIR/AW (super thermal-resistant Al alloy conductors Al-clad Invar-reinforced) overhead conductor which cans double ampacity has been developed. The STACIR/AW power line is mechanically composite stranded wire composed of INVAR/AW stranded wire as core for sag control and heat-resistant aluminum alloy for delivering doubled electric current. Recently, in order to ensure stable line operation and to predict its span of life, the changes of thermal properties for STACIR/AW have been investigated. In the present work, the changes of strain with temperature and the creep behavior as important factors in sag control will be presented. The transition temperature of STACIR/AW 410 sqmm was estimated approximately 130 C and the creep rates were decreased with temperatures. (orig.)

  2. Power Swing Detection in UPFC-Compensated Line by Phase Angle of Current

    DEFF Research Database (Denmark)

    Khodaparast, Jalal; Khederzadeh, M.; Silva, Filipe Miguel Faria da

    2017-01-01

    Power swing blocker (PSB) is a complementary part of distance relay protection, that detects power swing, in order to prevent unintended operation of a distance relay. Unified power flow controller (UPFC) is used in power system to control both active and reactive powers and its operation during...... condition. The results show that these indices may no longer work in systems with UPFC. In addition, this paper proposes a new method for detecting power swing based on the phase angle of current at relay point and compares it with two other methods. The new method distinguishes power swing from a fault...

  3. On estimation of reliability for pipe lines of heat power plants under cyclic loading

    International Nuclear Information System (INIS)

    Verezemskij, V.G.

    1986-01-01

    One of the possible methods to obtain a quantitative estimate of the reliability for pipe lines of the welded heat power plants under cyclic loading due to heating-cooling and due to vibration is considered. Reliability estimate is carried out for a common case of loading by simultaneous cycles with different amplitudes and loading asymmetry. It is shown that scattering of the breaking number of cycles for the metal of welds may perceptibly decrease reliability of the welded pipe line

  4. Bifenthrin activates homotypic aggregation in human T-cell lines.

    Science.gov (United States)

    Hoffman, Nataly; Tran, Van; Daniyan, Anthony; Ojugbele, Olutosin; Pryor, Stephen C; Bonventre, Josephine A; Flynn, Katherine; Weeks, Benjamin S

    2006-03-01

    Here, we addressed the concern that, despite the lack of overt toxicity, exposure to low levels of the common household pyrethroid pesticide, bifenthrin, could cause harm to the immune system. To do this, we measure the effect of bifenthrin on phytohemagglutinin (PHA) activation of homotypic aggregation in human T-cell lines. The human CD4+ H9, and Jurkat cell lines and the human promonocyte U937 cell line, were exposed to varying concentrations of bifenthrin. Cell viability was determined using the AlmarBlue Toxicity Assay. Concentrations of bifenthrin which did not reduce cell viability were determined and these concentrations were tested for the effect of bifenthrin on PHA-mediated homotypic aggregation. Blocking antibodies to ICAM and LFA-1 were used to disrupt aggregation and a nonspecific IgG was used as a control. Bifenthrin was found to be nontoxic at concentrations ranging from 10(-4) to 10(-13) M. Bifenthrin did not inhibit PHA induced cell aggregation in all cell lines tested. However, at 10(-4) M, bifenthrin to form aggregates stimulated homotypic aggregation in the H9 and Jurkat T-cell lines. The bifenthrin-induced aggregate formation, like that seen with PHA, was blocked by treating the cells with antibodies to either LFA-1 or ICAM. The results here show that bifenthrin activates T-cell function by stimulating ICAM/LFA-1 mediated homotypic aggregation. This data suggests that exposure to bifenthrin, even at "acceptable" limits, can increase the risk for and frequency of inflammatory responses and diseases such as asthma.

  5. Stability of emission line clouds in active galactic nuclei

    International Nuclear Information System (INIS)

    Krinsky, I.S.

    1989-01-01

    A numerical model was developed for a Quasar Stellar Object (QSO) broad emission line cloud (ELC) imbedded within a confining hot intercloud medium (HIM) for the purpose of studying its stability to perturbations in its temperature and density. A self-consistent model in radiative, pressure and thermal equilibrium is presented. The effect of trapped line radiation pressure is also included with the total pressure (particle plus radiation) held constant. The equilibrium model is found to have regions with radiation pressure exceeding gas pressure. Energy transport includes the effects of an external broken power law continuum and thermal conduction of heat from the HIM. Conduction is found to be unimportant to the total energy budget of the cloud, but is important to the dynamics of the ELC/HIM interface. Independent of the ELC/HIM model, an extension of second order probabilistic radiative transfer that treats the diffuse radiation field as composed of two oppositely directed streams is presented. The high ionization zone of the ELC is found to be unstable to radiatively driven sound waves. Both the external radiation field and the force of trapped line radiation are potential sources for driving the growth of sound waves. The final picture that emerges is that the ELC must be in a constant state of flux

  6. Artificial neural networks to estimate the EMF ELF on car travelling near power transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Al-Sayegh, O.A.; Qabazard, A.M. [Kuwait Inst. for Scientific Research, Safat (Kuwait). advanced Systems Division of Environment and Urban

    2007-07-01

    An artificial neural network (ANN) was developed to determine the electromagnetic field (EMF) and extremely low frequency (ELF) intensity on a vehicle body at different distances from a high tension power line and at varying power loads. EMF radiated emissions from ELF source power transmission lines can produce interference in the electric components in vehicles traveling at variable speed near the power lines. The passengers in the vehicle may also experience EMF-related health problems. Although EMF has been recently categorized as a new form of pollution, the situation has been largely ignored by the industry. Typically, electromagnetic fields at different frequencies show the fastest growing environmental influences. All populations are now exposed to varying degrees of EMF and the levels will continue to increase as technology advances. The purpose of this work was to promote discussion and help find design solutions to manufacture a new device for measuring the EMF at variable speed. In this study, a set of near field measurements outside the vehicle were used to train ANN. Estimations of the EMF ELF for various distances from the high tension power line were presented. It was determined that the most important factors affecting the electric field model include exposure conditions; size, shape and position of the exposed body in the field; and, surface charge density. The EMF ELF was found to increase near sagging areas of the overhead power transmission line. The EMF ELF was found to be proportional to the total amps flowing through the line at the time of measurement. 14 refs., 3 figs.

  7. Power grid, mains filtering and power line communications ... a root cause for incompatibilities

    NARCIS (Netherlands)

    Coenen, Mart

    2013-01-01

    The power grid is intentionally meant to distribute electrical energy at the mains frequency, as produced by the electricity generating plants, towards the end-users. The three-phase low-voltage distribution network can be utilized more efficiently when a power factor of 1 is achieved and no

  8. Enhanced power sharing in microgrids using the modified droop and virtual line impedance systems

    Energy Technology Data Exchange (ETDEWEB)

    Aghasafari, M.A.; Lopes, L.A.C.; Williamson, S. [Concordia Univ., Montreal, PQ (Canada). Power Electronics and Energy Research Group

    2009-06-15

    The microgrid is the local electricity network which connects several distributed energy systems. This paper proposed a control strategy which provided better power sharing than that of other control systems with low sensibility to the line unbalances, with fast and non-oscillatory responses. These distributed sources (which can include solar panels) were connected together using inverters in a low voltage microgrid. Power equations of the system were considered and presented from the droop strategy point of view and the importance of including virtual impedances in the control system was considered. The performance of the system was verified by means of simulations. Several illustrations and graphs were presented, including a simplified power stage of the system; power sharing variations by change in the first source voltage phase; power sharing variations as the first source voltage magnitude changes; power sharing variations by change in the system steady state frequency; and apparent power changes by change in the system steady state frequency. The control system and its levels was also illustrated including its four levels, namely an inverter current control loop; inverter voltage control loop; virtual resistance loop; and droop control loop. It was concluded that the control scheme for isolated microgrids yielded good speed, power sharing, and efficiency with small transient oscillations. The system could make good power sharing insensitive to the line unbalance. 8 refs., 1 tab., 11 figs.

  9. Improving the Power Quality in Tehran Metro Line-Two Using the Ant Colony Algorithm

    Directory of Open Access Journals (Sweden)

    H. Ehteshami

    2017-12-01

    Full Text Available This research aims to survey the improvement of power quality in Tehran metro line 2 using the ant colony algorithm and to investigate all the factors affecting the achievement of this goal. In order to put Tehran on the road of sustainable development, finding a solution for dealing with air pollution is essential. The use of public transportation, especially metro, is one of the ways to achieve this goal. Since the highest share of pollutants in Tehran belongs to cars and mobile sources, relative statistical indicators are estimated through assuming the effect of metro lines development and subsequently reduction of traffic on power quality index.

  10. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    OpenAIRE

    B. T. Hutsel; P. A. Corcoran; M. E. Cuneo; M. R. Gomez; M. H. Hess; D. D. Hinshelwood; C. A. Jennings; G. R. Laity; D. C. Lamppa; R. D. McBride; J. K. Moore; A. Myers; D. V. Rose; S. A. Slutz; W. A. Stygar

    2018-01-01

    We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-en...

  11. THROUGH-THE EARTH (TTE) SYSTEM AND THE IN-MINE POWER LINE (IMPL) SYSTEM

    International Nuclear Information System (INIS)

    Zvi H. Meiksin

    2001-01-01

    Work has progressed on both subsystems: the through-the-earth (TTE) system and the In-Mine Power Line (IMPL) system. After the Lab prototype of the IMPL system was perfected to function satisfactorily, the thrust of the work focused on building a first production prototype that can be installed and tested inside a mine. To obtain multi-channel voice communication through the TTE system, effort has proceeded to compress voice messages and make the format compatible with the power-line interface protocol

  12. Automatic drafting system for lined tanks used for nuclear power plants

    International Nuclear Information System (INIS)

    Sasaki, Ryoichi; Kikuchi, Nobuo

    1981-01-01

    The concrete vessels lined with metallic sheets are used widely in chemical and food industries and nuclear power plants. Especially in nuclear power plants, rectangular lined tanks have been adopted mainly to store radioactive liquid and solid wastes recently, because of the good volume efficiency. Though the basic structure of the lined tanks is the same, the volume and the form change according to the kinds of stored matters and the positions of pipe connections, and the form of individual lining sheets diversifies. As much labor and time are consumed for the drawing, automatic drafting was planned, and the conditions of application were studied. As for the conditions of application, the following metters are conceivable: the standardized method of design of equipments, the handling of figures numerically or by mathematical formulas, troublesome calculation, the works likely to cause mistake, many drawings for production and so on. The lined tanks almost satisfy these conditions, therefore the automatic drafting was promoted, and good results were obtained. the range of application of the automatic drafting system, the standardization of the form of lined tanks, the size of lining sheets, part number and welding number, the composition of the automatic drafting system, the outline of the program, and the effectiveness of automatic drafting are described. (Kako, I.)

  13. On-line monitoring applications at nuclear power plants. A risk informed approach to calibration reduction

    International Nuclear Information System (INIS)

    Shankar, Ramesh; Hussey, Aaron; Davis, Eddie

    2003-01-01

    On-line monitoring of instrument channels provides increased information about the condition of monitored channels through accurate, more frequent evaluation of each cannel's performance over time. This type of performance monitoring is a methodology that offers an alternate approach to traditional time-directed calibration. EPRI's strategic role in on-line monitoring is to facilitate its implementation and cost-effective use in numerous applications at power plants. To this end, EPRI has sponsored an on-line monitoring implementation project at multiple nuclear plants specifically intended to install and use on-line monitoring technology. The selected on-line monitoring method is based on the Multivariate State Estimation Technique. The project has a planned three-year life; seven plants are participating in the project. The goal is to apply on-line monitoring to all types of power plant applications and document all aspects of the implementation process in a series of EPRI reports. These deliverables cover installation, modeling, optimization, and proven cost-benefit. This paper discusses the actual implementation of on-line monitoring to various nuclear plant instrument systems. Examples of detected instrument drift are provided. (author)

  14. Long-pulse applications of pulse-forming lines for high-power linac application

    International Nuclear Information System (INIS)

    Hoeberling, R.F.; Tallerico, P.J.

    1981-01-01

    The ever present demands for high efficiency in the RF power stations for particle accelerators have caused increased interest in longer RF pulses (ten's of microseconds) for linacs such as the Pion Generator for Medical Irradiation (PIGMI) and Free Electron Laser (FEL). For either RF power station, a fundamental decision is whether to use a modulating anode/hard-tube driver or pulsed cathode/line-type pulser configuration. The choices in the extremes of low power for very long pulses or for very-high-power, short pulses are, respectively, a modulated anode/hard tube modulator and pulsed cathode/pulse forming line. However, the demarcation between these two extremes is not clearcut. The criteria (cost, flexibility performance, reliability, efficiency) that resulted in the RF station definition of these two specific systems will be described

  15. Power Ramp Limitation capabilities of Large PV Power Plants with Active Power Reserves

    DEFF Research Database (Denmark)

    Bogdan, Craciun; Kerekes, Tamas; Sera, Dezso

    2017-01-01

    Power Ramp Limitation (PRL) is likely to become a requirement for large scale photovoltaic power plants (LPVPPs) in order to allow the increase of PV penetration levels. Especially in islands with reduced inertia capability, this problem is more stringent: high power ramp can be caused by either...... fast irradiance changes or other participant generators for example wind power, or loads. In order to compensate for the power mismatch, LPVPPs must use Active Power Reserve (APR), by either curtailment or auxiliary storage. The paper proposes a PRL control structure for dynamic APR sizing...... and deployment. The selected test case is the power system of Puerto Rico (PREPA), modeled using the modified IEEE 12 bus benchmark system, with different levels of PV penetration. It is shown that LPVPP with PRL can effectively reduce the ramping rate of the participating generators. Considering that the large...

  16. Effect of voltage sags on digitally controlled line connected switched-mode power supplies

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2012-01-01

    Different voltage disorders like voltage fluctuations, sags, frequency variations may occur in the power supply networks due to different fault conditions. These deviations from normal operation affects in different ways the line connected devices. Standards were developed to protect and ensure...... of voltage sags is analyzed. Fault tolerant control algorithm was designed, implemented and is discussed. The fault conditions and their effects were investigated at different power levels....

  17. Magnet power supply control of the NSLS VUV and x-ray storage rings transfer lines

    International Nuclear Information System (INIS)

    Klein, J.D.; Ramamoorthy, S.; Singh, O.; Smith, J.D.

    1985-01-01

    The transfer lines for NSLS VUV and x-ray storage rings have been split. New power supplies have been incorporated with existing ones. The existing microprocessor system has been upgraded in order to control the additional functions. This system expands the input/output port of the microprocessor to an addressable serial/parallel link to each magnet power supply. The implementation of this system will be discussed

  18. An experimental investigation into power broadening of the Na-D lines in a flame

    International Nuclear Information System (INIS)

    Calcar, R.A. van.

    1980-01-01

    Investigations are described aimed at the verification of the existence of power broadening in fluorescence, as predicted by theory in the case of a broadband excitation source. Measurements were performed on a vapour of sodium (Na) atoms in a pre-mixed H 2 -O 2 -Ar flame under 1 atm pressure. The easily excited first resonance (or D) lines of Na were chosen for the observation of power broadening in fluorescence. (Auth.)

  19. Facts and feelings: Framing effects in responses to uncertainties about high-voltage power lines

    OpenAIRE

    de Vries, G.; de Bruijn, J.A.

    2017-01-01

    To ensure power supply security, electricity transmission system operators (TSOs) have to upscale high-voltage overhead power lines. However, upscaling frequently meets opposition. Opposition can be caused by uncertainties about risks and benefits and might lead to costly delays (Linder, 1995; Wiedemann, Boerner,& Claus, 2016). To minimize opposition, TSOs and related public services need to respond to these uncertainties in a credible and convincing (effective) way. Effective risk commun...

  20. Application of Coordinated SOFC and SMES Robust Control for Stabilizing Tie-Line Power

    Energy Technology Data Exchange (ETDEWEB)

    Ning Zhang; Wei Gu; Haojun Yu; Wei Liu [School of Electrical Engineering, Southeast University, Nanjing (China)

    2013-04-15

    Wind power causes fluctuations in power systems and introduces issues concerning system stability and power quality because of the lack of controllability of its discontinuous and intermittent resources. This paper presents a coordinated control strategy for solid oxide fuel cells (SOFCs) and superconducting magnetic energy storage (SMES) to match the intermittent wind power generation and compensate for the rapid load changes. An optimal H{sub {infinity}}control method, where the weighting function selection is expressed as an optimization problem, is proposed to mitigate tie-line power fluctuations and the mixed-sensitivity approach is used to deal with the interference suppression. Simulation results show that the proposed method significantly improves the smoothing effect of wind power fluctuations. Compared with the conventional control method, the proposed method has better anti-interference performance in various operating situations.

  1. Application of Coordinated SOFC and SMES Robust Control for Stabilizing Tie-Line Power

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2013-04-01

    Full Text Available Wind power causes fluctuations in power systems and introduces issues concerning system stability and power quality because of the lack of controllability of its discontinuous and intermittent resources. This paper presents a coordinated control strategy for solid oxide fuel cells (SOFCs and superconducting magnetic energy storage (SMES to match the intermittent wind power generation and compensate for the rapid load changes. An optimal H∞ control method, where the weighting function selection is expressed as an optimization problem, is proposed to mitigate tie-line power fluctuations and the mixed-sensitivity approach is used to deal with the interference suppression. Simulation results show that the proposed method significantly improves the smoothing effect of wind power fluctuations. Compared with the conventional control method, the proposed method has better anti-interference performance in various operating situations.

  2. Determination Of Maximum Power Of The RSG-Gas At Power Operation Mode Using One Line Cooling System

    International Nuclear Information System (INIS)

    Hastuti, Endiah Puji; Kuntoro, Iman; Darwis Isnaini, M.

    2000-01-01

    In the frame of minimizing the operation-cost, operation mode using one line cooling system is being evaluated. Maximum reactor power shall be determined to assure that the existing safety criteria are not violated. The analysis was done by means of a core thermal hydraulic code, COOLOD-N. The code solves core thermal hydraulic equation at steady state conditions. By varying the reactor power as the input, thermal hydraulic parameters such as fuel cladding and fuel meat temperatures as well as safety margin against flow instability were calculated. Imposing the safety criteria to the results, maximum permissible power for this operation was obtained as much as 17.1 MW. Nevertheless, for operation the maximum power is limited to 15MW

  3. On-line reconstruction of in-core power distribution by harmonics expansion method

    International Nuclear Information System (INIS)

    Wang Changhui; Wu Hongchun; Cao Liangzhi; Yang Ping

    2011-01-01

    Highlights: → A harmonics expansion method for the on-line in-core power reconstruction is proposed. → A harmonics data library is pre-generated off-line and a code named COMS is developed. → Numerical results show that the maximum relative error of the reconstruction is less than 5.5%. → This method has a high computational speed compared to traditional methods. - Abstract: Fixed in-core detectors are most suitable in real-time response to in-core power distributions in pressurized water reactors (PWRs). In this paper, a harmonics expansion method is used to reconstruct the in-core power distribution of a PWR on-line. In this method, the in-core power distribution is expanded by the harmonics of one reference case. The expansion coefficients are calculated using signals provided by fixed in-core detectors. To conserve computing time and improve reconstruction precision, a harmonics data library containing the harmonics of different reference cases is constructed. Upon reconstruction of the in-core power distribution on-line, the two closest reference cases are searched from the harmonics data library to produce expanded harmonics by interpolation. The Unit 1 reactor of DayaBay Nuclear Power Plant (DayaBay NPP) in China is considered for verification. The maximum relative error between the measurement and reconstruction results is less than 5.5%, and the computing time is about 0.53 s for a single reconstruction, indicating that this method is suitable for the on-line monitoring of PWRs.

  4. Wired: impacts of increasing power line use by a growing bird population

    Science.gov (United States)

    Moreira, Francisco; Encarnação, Vitor; Rosa, Gonçalo; Gilbert, Nathalie; Infante, Samuel; Costa, Julieta; D'Amico, Marcello; Martins, Ricardo C.; Catry, Inês

    2017-02-01

    Power lines are increasingly widespread across many regions of the planet. Although these linear infrastructures are known for their negative impacts on bird populations, through collision and electrocution, some species take advantage of electricity pylons for nesting. In this case, estimation of the net impact of these infrastructures at the population level requires an assessment of trade-offs between positive and negative impacts. We compiled historical information (1958-2014) of the Portuguese white stork Ciconia ciconia population to analyze long-term changes in numbers, distribution range and use of nesting structures. White stork population size increased 660% up to 12000 breeding pairs between 1984 and 2014. In the same period, the proportion of nests on electricity pylons increased from 1% to 25%, likely facilitated by the 60% increase in the length of the very high tension power line grid (holding the majority of the nests) in the stork’s distribution range. No differences in breeding success were registered for storks nesting on electricity pylons versus other structures, but a high risk of mortality by collision and electrocution with power lines was estimated. We discuss the implications of this behavioral change, and of the management responses by power line companies, both for stork populations and for managers.

  5. Interlaboratory comparison of measuring results of magnetic field near 400 kV overhead power line

    Directory of Open Access Journals (Sweden)

    Grbić Maja

    2012-01-01

    Full Text Available The paper presents a comparison of measured results of magnetic field near 400 kV overhead power lines obtained by three laboratories. This interlaboratory comparison was performed to ensure confidence in the quality of the test results. The measured results were analyzed with standard methods, using En number, based on which the evaluation of the laboratories was performed.

  6. Magnetic Field Exposure Estimates Based on Power Lines Near Homes (invited paper)

    International Nuclear Information System (INIS)

    Ahlbom, A.; Feychting, M.

    1999-01-01

    Several epidemiological studies have based their estimates of magnetic field exposure on the proximity to power lines. This has been done in three principally different ways, which differ in the amount of information that is used. These are: (1) distance; (2) distance and configuration (wire code); and (3) distance, configuration, and load (calculated field). It is presumed that the more information that is used, the more accurate is the exposure estimate. All these three approaches suffer from the limitation that they only account for exposure that is generated by power lines. The influence on the in-home magnetic field from sources other than the power line are not considered, nor is exposure experienced at places other than the home. This raises the following question. What is the implication for the result of the epidemiological study of the exposure misclassification that is introduced by basing magnetic field exposure estimation on power lines near homes? Although the necessary information is only partly at hand the answers to this question will be discussed. The basis will be some general epidemiological principles combined with data from a Swedish study on residential exposure and cancer risk. (author)

  7. Simulation of a Narrowband Power Line Communications System over Medium Voltage

    Directory of Open Access Journals (Sweden)

    Nikolaos Chiotellis

    2016-03-01

    Full Text Available Narrowband Power Line Communications (NB-PLCs are investigated as an alternative option for transferring low rate smart grid (SG data via Medium Voltage (MV power lines. In this framework, two variants of orthogonal frequency division multiplexing are examined, namely Filtered-OFDM (F-OFDM and Wavelet-OFDM (W-OFDM, in an attempt to determine which of them is capable of transmitting low rate SG data to greater distances over non-branched MV power lines. The reach of NB-PLC signals via MV power lines is estimated, taking into account the transfer function of the relevant PLC channels and noise mechanisms as well as the specific features of the two modulation options under consideration. Simulations show that NB-PLC transmission constitutes a technically feasible and economically affordable option for exchanging low rate data with remote SG nodes dispersed over the MV grid. Moreover, simulations show that F-OFDM allows low rate data transmission to considerably greater distances compared to W-OFDM.

  8. Measurement of magnetic fields in the direct proximity of power line conductors

    International Nuclear Information System (INIS)

    Mamishev, A.V.; Russell, B.D.

    1995-01-01

    Modeling and managing of power frequency magnetic fields requires verification of theory with actual measurements. Measurements only at ground level are not always sufficient for comprehensive studies. The technique and the results of three-dimensional mapping of the power frequency magnetic fields high above ground level are presented in this paper. Comparative calculations illustrate relevance and approximations of the existing theoretical approach to field modeling. The influence of harmonics on the elliptical rotation of the magnetic field vector is illustrated. The possibility of use of the magnetic fields for the power line proximity detection is discussed

  9. On-line measurement of microwave power in ECR ion source

    International Nuclear Information System (INIS)

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang; Li Xiaoyun

    2005-01-01

    It is a new technology to apply an ECR ion source to the neutron generator. Because of the structure limitation, working state of the ECR ion source could not be judged by the color of gas discharging in discharge chamber. Therefore, it was hard to estimate if the ECR ion source was working properly in the neutron generator. The method to resolve the problem was described in this paper. The microwave power was measured on-line by a directional coupler and a small microwave power meter. The ion beam current could be educed from the measured incidence microwave power, and discharge state in discharge chamber could be determined. (authors)

  10. Active and reactive power control of a current-source PWM-rectifier using space vectors

    Energy Technology Data Exchange (ETDEWEB)

    Salo, M.; Tuusa, H. [Tampere University of Technology (Finland). Department of Electrical Engineering, Power Electronics

    1997-12-31

    In this paper the current-source PWM-rectifier with active and reactive power control is presented. The control system is realized using space vector methods. Also, compensation of the reactive power drawn by the line filter is discussed. Some simulation results are shown. (orig.) 8 refs.

  11. Improvements of high-power diode laser line generators open up new application fields

    Science.gov (United States)

    Meinschien, J.; Bayer, A.; Bruns, P.; Aschke, L.; Lissotschenko, V. N.

    2009-02-01

    Beam shaping improvements of line generators based on high power diode lasers lead to new application fields as hardening, annealing or cutting of various materials. Of special interest is the laser treatment of silicon. An overview of the wide variety of applications is presented with special emphasis of the relevance of unique laser beam parameters like power density and beam uniformity. Complementary to vision application and plastic processing, these new application markets become more and more important and can now be addressed by high power diode laser line generators. Herewith, a family of high power diode laser line generators is presented that covers this wide spectrum of application fields with very different requirements, including new applications as cutting of silicon or glass, as well as the beam shaping concepts behind it. A laser that generates a 5m long and 4mm wide homogeneous laser line is shown with peak intensities of 0.2W/cm2 for inspection of railway catenaries as well as a laser that generates a homogeneous intensity distribution of 60mm x 2mm size with peak intensities of 225W/cm2 for plastic processing. For the annealing of silicon surfaces, a laser was designed that generates an extraordinary uniform intensity distribution with residual inhomogeneities (contrast ratio) of less than 3% over a line length of 11mm and peak intensities of up to 75kW/cm2. Ultimately, a laser line is shown with a peak intensity of 250kW/cm2 used for cutting applications. Results of various application tests performed with the above mentioned lasers are discussed, particularly the surface treatment of silicon and the cutting of glass.

  12. Troubleshooting of signal power supply system for Shanghai metro line 7

    Science.gov (United States)

    Lu, Kaixia; Xiao, Jie

    2018-03-01

    With the rapid development of Urban Rail Transit Signal Technology, the demand of signal power supply system for signal equipment is higher and higher. The signal intelligent power supply panel is the main component of the urban rail traffic signal power supply system. Whether the intelligent power supply panel working or not is directly related to traffic safety. The maintenance of intelligent signal power supply panel is particularly important. Line 7 of Shanghai Metro adopts PMZG Signal Intelligent Power Supply Panel, which is produced by Beijing Jinyujiaxin Polytron Technologies Inc. Maintenance of power supply system mainly includes routine maintenance and troubleshooting. This article will make clear the routine maintenance contents of PMZG Signal Intelligent Power Supply Panel, and put forward the common fault information and troubleshooting methods of PMZG Signal Intelligent Power Supply Panel. In accordance with the steps of fault handling, the faults can be eliminated in the shortest possible time, and PMZG Signal Intelligent Power Supply Panel can be quickly restored to normal working state.

  13. A Simplified Control Method for Tie-Line Power of DC Micro-Grid

    Directory of Open Access Journals (Sweden)

    Yanbo Che

    2018-04-01

    Full Text Available Compared with the AC micro-grid, the DC micro-grid has low energy loss and no issues of frequency stability, which makes it more accessible for distributed energy. Thus, the DC micro-grid has good potential for development. A variety of renewable energy is included in the DC micro-grid, which is easily affected by the environment, causing fluctuation of the DC voltage. For grid-connected DC micro-grid with droop control strategy, the tie-line power is affected by fluctuations in the DC voltage, which sets higher requirements for coordinated control of the DC micro-grid. This paper presents a simplified control method to maintain a constant tie-line power that is suitable for the DC micro-grid with the droop control strategy. By coordinating the designs of the droop control characteristics of generators, energy storage units and grid-connected inverter, a dead band is introduced to the droop control to improve the system performance. The tie-line power in the steady state is constant. When a large disturbance occurs, the AC power grid can provide power support to the micro-grid in time. The simulation example verifies the effectiveness of the proposed control strategy.

  14. Decentralized automatic generation control of interconnected power systems incorporating asynchronous tie-lines.

    Science.gov (United States)

    Ibraheem; Hasan, Naimul; Hussein, Arkan Ahmed

    2014-01-01

    This Paper presents the design of decentralized automatic generation controller for an interconnected power system using PID, Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The designed controllers are tested on identical two-area interconnected power systems consisting of thermal power plants. The area interconnections between two areas are considered as (i) AC tie-line only (ii) Asynchronous tie-line. The dynamic response analysis is carried out for 1% load perturbation. The performance of the intelligent controllers based on GA and PSO has been compared with the conventional PID controller. The investigations of the system dynamic responses reveal that PSO has the better dynamic response result as compared with PID and GA controller for both type of area interconnection.

  15. Electromagnetic interference produced by power or electrified railway lines on metallic pipe networks

    International Nuclear Information System (INIS)

    Lucca, G.

    1999-01-01

    The paper presents an algorithm for the calculation, in the frequency domain, of the induced voltages and currents on a generic metallic pipe network exposed to the electromagnetic interference from a power line or an electrified railway line. By assuming as known the voltages and the currents on the inducing line, the algorithm may be subdivided into the following main steps: a) determination of the ideal electromotive force and current generators to be applied to the induced structure in order to represent the electromagnetic influence from the inducing line; b) modelling of the pipe network by means of a suitable equivalent electric network; c) calculation of voltages and currents on the induced network [it

  16. Power charging and discharging characteristics of smes connected to artificial transmission line

    International Nuclear Information System (INIS)

    Nitta, T.; Okada, T.; Shirai, Y.

    1985-01-01

    To consider the characteristics of SMES and to investigate problems on the operations of SMES in power systems, we carried out some experiments on an experimental network. In the network, a small superconducting magnet is connected to a small synchronous generator through a double thyristorized converter and transformers. The generator is connected to the regional power system through artifitial transmission lines, AC power into or out of SMES and reactive power are controlled. Furthermore, a computer simulation program is made for the experimental system. The results of the simulation are compared with those of the experiments. For the experiments and the simulation, the harmonics current-flow, power-flow, characteristics of the generator and so on, are discussed

  17. Power electron beam front shortening in magnetically insulated transmission line with inner coaxial dielectric insert

    International Nuclear Information System (INIS)

    Galstjan, E.A.; Kazanskiy, L.N.

    1995-01-01

    By now the technology of high-power high-current relativistic electron beams with microsecond duration has been developed. The same technology is used in high-power electric pulse generation. However at present the high-power beams of subnanosecond duration are necessary for some investigations and applications. The maximum power parameter achieved by means of the usual technology is limited by a value in the range of 100-300 MW. For this reason a search for new ways to generate high-power REB (relativistic electron beam) is a topical problem. It is obvious that this problem may be reduced to the generation of pulses with a subnanosecond front duration. There are many methods to shorten a pulse duration to its front duration for instance, by using parts of short-circuited transmission lines

  18. Wireless power pad with local power activation for portable devices

    NARCIS (Netherlands)

    Waffenschmidt, E.; Zheglov, V.

    2007-01-01

    Wireless power transfer by magnetic induction offers a simple to use way to recharge mobile devices like e.g. mobile phone, music players or medical sensors. As shown by a previous report and an existing Power Pad demonstrator, wireless inductive power transfer is possible with a good power

  19. In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Steffen; Weigel, Robert; Koelpin, Alexander [Institute for Electronics Engineering, University of Erlangen-Nuremberg, Cauerstr. 9, 91058 Erlangen (Germany); Dennerlein, Juergen; Janke, Iryna; Weber, Johannes [AREVA GmbH, Paul-Gossen-Str. 100, 91052 Erlangen (Germany)

    2015-07-01

    Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

  20. Managing Siting Activities for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-06-15

    One of the IAEA's statutory objectives is to ''seek to accelerate and enlarge the contribution of atomic energy to peace, health and prosperity throughout the world''. One way this objective is achieved is through the publication of a range of technical series. Two of these are the IAEA Nuclear Energy Series and the IAEA Safety Standards Series. According to Article III.A.6 of the IAEA Statute, the safety standards establish 'standards of safety for protection of health and minimization of danger to life and property.' The safety standards include the Safety Fundamentals, Safety Requirements and Safety Guides. These standards are written primarily in a regulatory style, and are binding on the IAEA for its own programmes. The principal users are the regulatory bodies in Member States and other national authorities. The IAEA Nuclear Energy Series comprises reports designed to encourage and assist R and D on, and application of, nuclear energy for peaceful uses. This includes practical examples to be used by owners and operators of utilities in Member States, implementing organizations, academia, and government officials, among others. This information is presented in guides, reports on technology status and advances, and best practices for peaceful uses of nuclear energy based on inputs from international experts. The IAEA Nuclear Energy Series complements the IAEA Safety Standards Series. The introduction of nuclear power brings new challenges to States - one of them being the selection of appropriates sites. It is a project that needs to begin early, be well managed, and deploy good communications with all stakeholders; including regulators. This is important, not just for those States introducing nuclear power for the first time, but for any State looking to build a new nuclear power plant. The purpose of the siting activities goes beyond choosing a suitable site and acquiring a licence. A large part of the project is about producing and maintaining a validated

  1. Managing Siting Activities for Nuclear Power Plants

    International Nuclear Information System (INIS)

    2012-01-01

    One of the IAEA's statutory objectives is to ''seek to accelerate and enlarge the contribution of atomic energy to peace, health and prosperity throughout the world''. One way this objective is achieved is through the publication of a range of technical series. Two of these are the IAEA Nuclear Energy Series and the IAEA Safety Standards Series. According to Article III.A.6 of the IAEA Statute, the safety standards establish 'standards of safety for protection of health and minimization of danger to life and property.' The safety standards include the Safety Fundamentals, Safety Requirements and Safety Guides. These standards are written primarily in a regulatory style, and are binding on the IAEA for its own programmes. The principal users are the regulatory bodies in Member States and other national authorities. The IAEA Nuclear Energy Series comprises reports designed to encourage and assist R and D on, and application of, nuclear energy for peaceful uses. This includes practical examples to be used by owners and operators of utilities in Member States, implementing organizations, academia, and government officials, among others. This information is presented in guides, reports on technology status and advances, and best practices for peaceful uses of nuclear energy based on inputs from international experts. The IAEA Nuclear Energy Series complements the IAEA Safety Standards Series. The introduction of nuclear power brings new challenges to States - one of them being the selection of appropriates sites. It is a project that needs to begin early, be well managed, and deploy good communications with all stakeholders; including regulators. This is important, not just for those States introducing nuclear power for the first time, but for any State looking to build a new nuclear power plant. The purpose of the siting activities goes beyond choosing a suitable site and acquiring a licence. A large part of the project is about producing and maintaining a validated

  2. The line-emitting gas in active galaxies - A probe of the nuclear engine

    Science.gov (United States)

    Veilleux, Sylvain

    1993-01-01

    This paper reviews some of the basic questions regarding the structure of the engine powering active galactic nuclei (AGN), the nature of the interaction between the AGN and the host galaxy, and the origin and evolution of AGN. The study of the dynamics and physical characteristics of the line-emitting gas in these objects has proven fruitful in addressing many of these issues. Recent advances in optical and infrared detector technology combined with the development of superior ground-based instruments have produced efficient new tools for the study of the line-emitting gas on nuclear and Galactic scales. Programs which take advantage of two of these new techniques, Fabry-Perot imaging spectroscopy and infrared spectroscopy, are described in this paper. The origin of nuclear activity in galaxies is also addressed in a third project which aims at determining the nature of luminous infrared galaxies.

  3. On-line tuning of a fuzzy-logic power system stabilizer

    International Nuclear Information System (INIS)

    Hossein-Zadeh, N.; Kalam, A.

    2002-01-01

    A scheme for on-line tuning of a fuzzy-logic power system stabilizer is presented. firstly, a fuzzy-logic power system stabilizer is developed using speed deviation and accelerating power as the controller input variables. The inference mechanism of fuzzy-logic controller is represented by a decision table, constructed of linguistic IF-THEN rules. The Linguistic rules are available from experts and the design procedure is based on these rules. It assumed that an exact model of the plant is not available and it is difficult to extract the exact parameters of the power plant. Thus, the design procedure can not be based on an exact model. This is an advantage of fuzzy logic that makes the design of a controller possible without knowing the exact model of the plant. Secondly, two scaling parameters are introduced to tune the fuzzy-logic power system stabilizer. These scaling parameters are the outputs of another fuzzy-logic system, which gets the operating conditions of power system as inputs. These mechanism of tuning the fuzzy-logic power system stabilizer makes the fuzzy-logic power system stabilizer adaptive to changes in the operating conditions. Therefore, the degradation of the system response, under a wide range of operating conditions, is less compared to the system response with a fixed-parameter fuzzy-logic power system stabilizer and a conventional (linear) power system stabilizer. The tuned stabilizer has been tested by performing nonlinear simulations using a synchronous machine-infinite bus model. The responses are compared with a fixed parameters fuzzy-logic power system stabilizer and a conventional (linear) power system stabilizer. It is shown that the tuned fuzzy-logic power system stabilizer is superior to both of them

  4. Corona Onset Characteristics of Bundle Conductors in UHV AC Power Lines at 2200 m Altitude

    Directory of Open Access Journals (Sweden)

    Shilong Huang

    2018-04-01

    Full Text Available The corona onset characteristic of bundle conductors is an important limiting factor for the design of UHV AC power lines in high-altitude areas. An experimental study on the corona characteristics of 8 × LGJ630, 6 × LGJ720, 8 × LGJ720 and 10 × LGJ720 bundle conductors commonly used in UHV power lines under dry and wet conductor conditions, as well as artificial moderate and heavy rain conditions, was conducted in Ping’an County, Xining City (elevation 2200 m. By using the tangent line method, the corona onset voltages and onset electric field of four types of conductors at high altitudes are obtained for the first time. In addition, the calculation model of corona onset voltage considering the outer strands’ effect on the electric field and the geometric factor in the corona cage in high altitude areas is established. The comparison of the calculation results and experimental results under dry conditions verifies the model’s correctness. Based on the results, an optimal selection scheme for high altitudes is proposed. The roughness coefficient was also calculated and analysed: the roughness coefficient of bundled conductors was between 0.59 and 0.77, and the roughness coefficient of the wet conductor was between the dry and rainy conditions. Both the experimental data and the calculation model can provide a reference for conductor selection for UHV AC power lines for use in high-altitude areas.

  5. Software for evaluating magnetic induction field generated by power lines: implementation of a new algorithm

    International Nuclear Information System (INIS)

    Comelli, M.; Benes, M.; Bampo, A.; Villalta, R.

    2006-01-01

    The Regional Environment Protection Agency of Friuli Venezia Giulia (A.R.P.A. F.V.G., Italy) has performed an analysis on existing software designed to calculate magnetic induction field generated by power lines. As far as the agency requirements are concerned the tested programs display some difficulties in the immediate processing of electrical and geometrical data supplied by plant owners, and in certain cases turn out to be inadequate in representing complex configurations of power lines. Furthermore, none of them is preset for cyclic calculus to determine the time evolution of induction in a certain exposure area. Finally, the output data are not immediately importable by ArcView, the G.I.S. used by A.R.P.A. F.V.G., and it is not always possible to implement the territory orography to determine the field at specified heights above the ground. P.h.i.d.e.l., an innovative software, tackles and works out al l the above mentioned problems. The power line wires interested in its implementation are represented by poly lines, and the field is analytically calculated, with no further approximation, not even when more power lines are concerned. Therefore, the obtained results, when compared with those of other programs, are the closest to experimental measurements. The output data can be employed both in G.I.S. and Excel environments, allowing the immediate overlaying of digital cartography and the determining of the 3 and 10 μT bands, in compliance with the Italian Decree of the President of the Council of Ministers of 8 July 2003. (authors)

  6. THE JET POWER AND EMISSION-LINE CORRELATIONS OF RADIO-LOUD OPTICALLY SELECTED QUASARS

    International Nuclear Information System (INIS)

    Punsly, Brian; Zhang Shaohua

    2011-01-01

    In this Letter, the properties of the extended radio emission form Sloan Digital Sky Survey Data Release 7 quasars with 0.4 20-30 kpc). The frequency of quasars with FR II level extended radio emission is ∼2.3% and >0.4% of quasars have FR I level extended radio emission. The lower limit simply reflects the flux density limit of the survey. The distribution of the long-term time-averaged jet powers of these quasars, Q-bar , has a broad peak ∼3 x 10 44 erg s -1 that turns over below 10 44 erg s -1 and sources above 10 45 erg s -1 are extremely rare. It is found that the correlation between the bolometric (total thermal) luminosity of the accretion flow, L bol , and Q-bar is not strong. The correlation of Q-bar with narrow line luminosity is stronger than the correlation with broad line luminosity and the continuum luminosity. It is therefore concluded that previous interpretations of correlations of Q-bar with narrow line strengths in radio galaxies as a direct correlation of jet power and accretion power have been overstated. It is explained why this interpretation mistakenly overlooks the sizeable fraction of sources with weak accretion luminosity and powerful jets discovered by Ogle et al.

  7. A methodology for on-line fatigue life monitoring of Indian nuclear power plant components

    International Nuclear Information System (INIS)

    Mukhopadhyay, N.K.; Dutta, B.K.; Kushawaha, H.S.

    1992-01-01

    Fatigue is one of the most important aging effects of nuclear power plant components. Information about accumulation of fatigue helps in assessing structural degradation of the components. This assists in-service inspection and maintenance and may also support future life extension program of a plant. In the present report a methodology is being proposed for monitoring on line fatigue life of nuclear power plant components using available plant instrumentations. Major factors affecting fatigue life of a nuclear power plant components are the fluctuations of temperature, pressure and flow rate. Green's function technique is used in on line fatigue monitoring as computation time is much less than finite element method. A code has been developed which computes temperature and stress Green's functions in 2-D and axisymmetric structure by finite element method due to unit change in various fluid parameters. A post processor has also been developed which computes the temperature and stress responses using corresponding Green's functions and actual fluctuation in fluid parameters. In this post processor, the multiple site problem is solved by superimposing single site Green's function technique. It is also shown that Green's function technique is best suited for on line fatigue life monitoring of nuclear power plant components. (author). 6 refs., 43 figs

  8. An automated system for monitoring bird collisions with power lines and tower guys

    Energy Technology Data Exchange (ETDEWEB)

    Carlton, R.G. [Electric Power Research Inst., Palo Alto, CA (United States)

    2005-07-01

    An automated system for monitoring collisions between birds and power lines was presented. The bird strike indicator (BSI) was developed to gather bird collision information that is difficult to obtain through direct human observation as well as to aid in the calculation of inherent biases which must be considered when attempting to determine total mortality from data obtained in on-the-ground dead bird searches. The BSI can be placed directly on power lines, static wires, or tower guy cables with a standard hot stick power line clamp. The sensor consists of a state-of-the-art accelerometers, power supplies, signal processors, and data acquisition systems. The BSI also includes a communication system for transmitting data to a ground-based unit in which raw data can be stored. A complete BSI consists of 30 sensors with signal processing and data logging capabilities, and a base station. The sensors integrate several components, including wireless radio, data storage, and a microcontroller with an A/D converter. Full-scale field deployment has shown that the BSI is both robust and sensitive to vibrations in the guy wires, as the system has been tuned to eliminate vibrations induced by wind. 3 figs.

  9. Review of first line supervisory positions in nuclear power plants - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Mackenzie, C W; Huntley, M [Hickling Corp., Ottawa, ON (Canada)

    1995-10-01

    This report provides an overview of first line supervisory activities at Ontario Hydro nuclear generating stations (Pickering `A` and Bruce `B`) and the Point Lepreau nuclear generating station in New Brunswick. Activity profiles describing the range of first line supervisory roles and responsibilities for nuclear operators have been developed from survey data and flowcharting methods. These activity profiles have then been compared with formal job responsibilities as identified in job descriptions, supervisory training provided and assessment criteria used to evaluate supervisors. Finally, this report relates the findings of supervisory practices in the group under study with the findings in the current literature relating to supervisory functioning. (author). 32 tabs., 2 figs.

  10. Review of first line supervisory positions in nuclear power plants - Phase II

    International Nuclear Information System (INIS)

    Mackenzie, C.W.; Huntley, M.

    1995-10-01

    This report provides an overview of first line supervisory activities at Ontario Hydro nuclear generating stations (Pickering 'A' and Bruce 'B') and the Point Lepreau nuclear generating station in New Brunswick. Activity profiles describing the range of first line supervisory roles and responsibilities for nuclear operators have been developed from survey data and flowcharting methods. These activity profiles have then been compared with formal job responsibilities as identified in job descriptions, supervisory training provided and assessment criteria used to evaluate supervisors. Finally, this report relates the findings of supervisory practices in the group under study with the findings in the current literature relating to supervisory functioning. (author). 32 tabs., 2 figs

  11. Adaptive intelligent power systems: Active distribution networks

    International Nuclear Information System (INIS)

    McDonald, Jim

    2008-01-01

    Electricity networks are extensive and well established. They form a key part of the infrastructure that supports industrialised society. These networks are moving from a period of stability to a time of potentially major transition, driven by a need for old equipment to be replaced, by government policy commitments to cleaner and renewable sources of electricity generation, and by change in the power industry. This paper looks at moves towards active distribution networks. The novel transmission and distribution systems of the future will challenge today's system designs. They will cope with variable voltages and frequencies, and will offer more flexible, sustainable options. Intelligent power networks will need innovation in several key areas of information technology. Active control of flexible, large-scale electrical power systems is required. Protection and control systems will have to react to faults and unusual transient behaviour and ensure recovery after such events. Real-time network simulation and performance analysis will be needed to provide decision support for system operators, and the inputs to energy and distribution management systems. Advanced sensors and measurement will be used to achieve higher degrees of network automation and better system control, while pervasive communications will allow networks to be reconfigured by intelligent systems

  12. Using technique vibration diagnostics for assessing the quality of power transmission line supports repairs

    Directory of Open Access Journals (Sweden)

    Cherpakov Aleksander

    2017-01-01

    Full Text Available The considered method for assessing the quality of the repair work to restore the rack supports of transmission lines is based on the method of vibration diagnostics. Power transmission line supports with a symmetrical destruction of the protective layer of concrete in the ground in violation of the construction section were chosen as an object. Finite element modelling package Ansys was used in assessing the quality of repair work. The example of evaluating the quality of repair using the relative adhesion defective area design criteria in the analysis of natural vibration frequencies is given.

  13. System design of the traction power supply for the high-speed line Beijing - Tianjin

    Energy Technology Data Exchange (ETDEWEB)

    Altmann, Martin; Fischer, Andreas; Tornow, Torsten [Siemens AG, Erlangen (Germany)

    2011-11-15

    The high-speed line Beijing - Tianjin connecting the Capital Beijing with the harbour city Tianjin is the first high-speed line in China dedicated only to passenger traffic and is operated at 300 km/h. The commercial service started in due time for the Olympic games in 2008. For the system design and a reliable traction power supply the simulation software Sitras {sup registered} Sidytrac was used. The program incorporates all modules necessary for the overall system design and relating detailed investigations. Measurements during system integration test validated the simulation results. (orig.)

  14. Control of single-phase islanded PV/battery minigrids based on power-line signaling

    DEFF Research Database (Denmark)

    Quintana, Pablo; Guerrero, Josep M.; Dragicevic, Tomislav

    2014-01-01

    should be utilized as efficiently as possible. This paper proposes a coordinated control strategy based on power-line signaling (PLS), instead of common communications, for a single-phase minigrid in which each unit can operate in different operation modes taking into account the resource limitation...... types of renewable energy sources (RES) and energy storage systems (ESS). Specifically, the recharging process of secondary battery, the most prominent ESS, should be done in a specific manner to preserve its life-time, microgrid line voltage must be kept within the bounds and the energy offered by RES...

  15. High-resolution molecular line observations of active galaxies

    Science.gov (United States)

    García-Burillo, S.; Combes, F.; Usero, A.; Graciá-Carpio, J.

    2008-10-01

    The study of the content, distribution and kinematics of interstellar gas is a key to understand the origin and maintenance of both starburst and nuclear (AGN) activity in galaxies. The processes involved in AGN fueling encompass a wide range of scales, both spatial and temporal, which have to be studied. Probing the gas flow from the outer disk down to the central engine of an AGN host, requires the use of specific tracers of the interstellar medium adapted to follow the change of phase of the gas as a function of radius. Current mm-interferometers can provide a sharp view of the distribution and kinematics of molecular gas in the circumnuclear disks of galaxies through extensive CO line mapping. As such, CO maps are an essential tool to study AGN feeding mechanisms in the local universe. This is the scientific driver of the NUclei of GAlaxies (NUGA) survey, whose latest results are here reviewed. On the other hand, the use of specific molecular tracers of the dense gas phase can probe the feedback influence of activity on the chemistry and energy balance/redistribution in the interstellar medium of nearby galaxies. Millimeter interferometers are able to unveil the strong chemical differentiation present in the molecular gas disks of nearby starbursts and AGNs. Nearby active galaxies can be used as local templates to address the study of more distant galaxies where both star formation and AGN activity are deeply embedded.

  16. Onboard power line conditioning system for an electric or hybrid vehicle

    Science.gov (United States)

    Kajouke, Lateef A.; Perisic, Milun

    2016-06-14

    A power line quality conditioning system for a vehicle includes an onboard rechargeable direct current (DC) energy storage system and an onboard electrical system coupled to the energy storage system. The energy storage system provides DC energy to drive an electric traction motor of the vehicle. The electrical system operates in a charging mode such that alternating current (AC) energy from a power grid external to the vehicle is converted to DC energy to charge the DC energy storage system. The electrical system also operates in a vehicle-to-grid power conditioning mode such that DC energy from the DC energy storage system is converted to AC energy to condition an AC voltage of the power grid.

  17. Study of data transmission over drive motor power cables of a remotely operated robot using power line communication technology

    International Nuclear Information System (INIS)

    Balaji, Kanchi; Singh, Ashutosh Pratap; Rakesh, V.; Rajagopalan, C.; Murugan, S.

    2016-01-01

    In nuclear power plants (NPPs), robotic devices are widely used for carrying out in-service inspection (lSI) and repair tasks at elevated temperatures and radiation environments. These devices comprises servo motors that are powered and controlled by the motion control unit/electric drives. The control and inspection data are to be transmitted back from the inspection device to the control unit using separate industrial graded data transmission cables compatible for high temperature applications. This increases complexity of robot trailing cables and cost. Hence, it is proposed to use power cables that are used for powering the motor for sending information signals using power line communication (PLC) technology. The domestically used PLC modems adds noise to the information signal when coupled on to the motor feed cables during IGBT switching. Therefore, passive low pass filters are used at the motor drive end to reduce the impulsive noise. The aim of this study is to compare noise characteristics for different type of filter structures over pulse width modulation (PWM) network. We will highlight the choice of cut off frequency of filter based on frequency of information signal

  18. Deep convolutional neural network processing of aerial stereo imagery to monitor vulnerable zones near power lines

    Science.gov (United States)

    Qayyum, Abdul; Saad, Naufal M.; Kamel, Nidal; Malik, Aamir Saeed

    2018-01-01

    The monitoring of vegetation near high-voltage transmission power lines and poles is tedious. Blackouts present a huge challenge to power distribution companies and often occur due to tree growth in hilly and rural areas. There are numerous methods of monitoring hazardous overgrowth that are expensive and time-consuming. Accurate estimation of tree and vegetation heights near power poles can prevent the disruption of power transmission in vulnerable zones. This paper presents a cost-effective approach based on a convolutional neural network (CNN) algorithm to compute the height (depth maps) of objects proximal to power poles and transmission lines. The proposed CNN extracts and classifies features by employing convolutional pooling inputs to fully connected data layers that capture prominent features from stereo image patches. Unmanned aerial vehicle or satellite stereo image datasets can thus provide a feasible and cost-effective approach that identifies threat levels based on height and distance estimations of hazardous vegetation and other objects. Results were compared with extant disparity map estimation techniques, such as graph cut, dynamic programming, belief propagation, and area-based methods. The proposed method achieved an accuracy rate of 90%.

  19. Damping of power oscillations of exchange lines using a DC link; Amortecimento de oscilacoes de potencia de linhas de intercambio utilizando um elo de CC

    Energy Technology Data Exchange (ETDEWEB)

    Paccini, Rodrigo de O.; Custodio, Diogo T.; Kopcak, Igor; Costa, Vivaldo F. da [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Dept. de Sistemas de Energia Eletrica], Emails: rodrigo@dsee.fee.unicamp.br, totti@dsee.fee.unicamp.br, kopcak@dsee.fee.unicamp.br, vivaldo@dsee.fee.unicamp.br.

    2009-07-01

    This article presents a study that evaluates the effectiveness of a DC link in order to damp power oscillations, of inter area exchange, under small disturbance conditions, operating with Automatic Control Generation. The DC link was represented by a power injection model included the Sensitivity Power Model. Through this representation, the DC link was inserted in the block diagram, modeled as an injection power in the bars terminals in the net active and reactive, closing a new power balance at every instant. It was also designed a controller for damping power oscillations (POD-Power Oscillation Damping Controller) for modulation the power of the DC link and, therefore, insertion of additional damping in a frequency oscillations of exchange lines. The results confirm that the DC link has a great potential for maintaining the damping of oscillations frequency so inter area when equipped with POD controllers.

  20. Smart Grid Applications for a Practical Implementation of IP over Narrowband Power Line Communications

    Directory of Open Access Journals (Sweden)

    Noelia Uribe-Pérez

    2017-11-01

    Full Text Available Currently, Advanced Metering Infrastructure (AMI systems have equipped the low voltage section with a communication system that is being used mainly for metering purposes, but it can be further employed for additional applications related to the Smart Grid (SG concept. This paper explores the potential applications beyond metering of the available channel in a Power Line Communication-based AMI system. To that end, IP has been implemented over Narrow Band-Power Line Communication (NB-PLC in a real microgrid, which includes an AMI system. A thorough review of potential applications for the SG that might be implemented for this representative case is included in order to provide a realistic analysis of the potentiality of NB-PLC beyond smart metering. The results demonstrate that existing AMI systems based on NB-PLC have the capacity to implement additional applications such as remote commands or status signals, which entails an added value for deployed AMI systems.

  1. Power line policy in practice. A pilot study; Hoogspanningslijnenbeleid in de praktijk. Een pilotonderzoek

    Energy Technology Data Exchange (ETDEWEB)

    Kelfkens, G.; Pruppers, M.J.M.

    2008-07-01

    A Quick Scan performed by RIVM among twelve municipalities with an overhead power line revealed that half of these municipalities were not aware of the power line policy recommended by the Netherlands Ministry of Housing, Spatial Planning and the Environment (VROM). Those municipalities where power lines are an (openly) debated public issue are generally well-informed on the recommended policy. Due to public pressure, these latter municipalities often take more stringent measures than those advised by the VROM; these include implementing specific measures for existing neighbourhoods and/or postponing construction plans for new neighbourhoods that have already received council approval. None of the municipalities interviewed had an information service specifically aimed at providing their residents with information on power lines. Results from international epidemiological investigations point to the possibility that children living in the vicinity of overhead power lines may have an enhanced risk of developing childhood leukaemia. At the end of 2005 the VROM issued a policy advice for municipalities, provinces and grid companies. The aim of this policy advice is to prevent situations from developing where children can be subjected to long-term exposure to magnetic fields due to overhead power lines. In such new situations, the Ministry advises local governments to reserve a buffer zone near the power line that is to be kept empty of home residences, schools and day-care centres. As the policy advice focuses on the framing or changing of zoning plans - procedures which may take several years - it is currently impossible to evaluate if this policy advice issued in 2005 has been successful. The Quick Scan was performed by order of the Inspectorate of the Ministry of Housing, Spatial Planning and the Environment of the Northwest Region of the Netherlands. The aim of the Inspectorate was to evaluate the role of the policy advice at the municipal level and the degree to

  2. Grid-Connection Half-Bridge PV Inverter System for Power Flow Controlling and Active Power Filtering

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2012-01-01

    Full Text Available A half-bridge photovoltaic (PV system is proposed, which can not only deal with bidirectional power flowing but also improve power quality. According to varying insolation, the system conditions real power for dc and ac loads to accommodate different amounts of PV power. Furthermore, the system eliminates current harmonics and improves power factor simultaneously. As compared with conventional PV inverter, the total number of active switches and current sensors can be reduced so that its cost is lower significantly. For current command determination, a linear-approximation method (LAM is applied to avoid the complicated calculation and achieve the maximum power point tracking (MPPT feature. For current controlling, a direct-source-current-shaping (DSCS algorithm is presented to shape the waveform of line current. Simulation results and practical measurements also demonstrate the feasibility of the proposed half-bridge PV system.

  3. Effects of indirect lightning strokes on lossy power distribution lines in the presence of nonlinear loads

    International Nuclear Information System (INIS)

    Rahimian, M. S.; Sadeghi, S. H. H.; Moini, R.

    2003-01-01

    Cloud-to-ground lightning strokes can include dangerous overvoltage on power distribution overhead lines. In this paper, a new algorithm is propagated within a distribution network including nonlinear apparatus. The coupling between the lightning channel and the overhead line is based on an antenna theory model and employs the method of moment for solving the governing electric field integral equation. The computed induced overvoltage is then used in the electromagnetic transient program to analyze its propagation within the distribution network. In this regard, the accuracy of the new coupling method is demonstrated by comparing the calculated induced over voltages using the new method and those obtained using the conventional methods. Simulation results are presented to show how the induced overvoltage is penetrated in a typical distribution network, consisting of overhead lines and underground cables, a distribution transformer protected by surge arresters and a three-phase resistive load

  4. Accurate fault location algorithm on power transmission lines with use of two-end unsynchronized measurements

    Directory of Open Access Journals (Sweden)

    Mohamed Dine

    2012-01-01

    Full Text Available This paper presents a new approach to fault location on power transmission lines. This approach uses two-end unsynchronised measurements of the line and benefits from the advantages of digital technology and numerical relaying, which are available today and can easily be applied for off-line analysis. The approach is to modify the apparent impedance method using a very simple first-order formula. The new method is independent of fault resistance, source impedances and pre-fault currents. In addition, the data volume communicated between relays is sufficiently small enough to be transmitted easily using a digital protection channel. The proposed approach is tested via digital simulation using MATLand the applied test results corroborate the superior performance of the proposed approach.

  5. Review of the first line supervisory positions in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Mullin, D; Mackenzie, C W [Hickling Corp. (Canada)

    1995-10-01

    The authors review the nature of the tasks performed by first line maintenance supervisors in three nuclear power plants. They compare these tasks to core supervisory training curriculum, supervisory job descriptions, and both the process related to performance appraisals, and the criteria applied in carrying out these performance evaluations. Recommendations have been made concerning methods of increasing the relevancy of training and improving the performance appraisal process. ( author). 5 figs.

  6. Review of the first line supervisory positions in nuclear power plants

    International Nuclear Information System (INIS)

    Mullin, D.; Mackenzie, C.W.

    1995-10-01

    The authors review the nature of the tasks performed by first line maintenance supervisors in three nuclear power plants. They compare these tasks to core supervisory training curriculum, supervisory job descriptions, and both the process related to performance appraisals, and the criteria applied in carrying out these performance evaluations. Recommendations have been made concerning methods of increasing the relevancy of training and improving the performance appraisal process. ( author). 5 figs

  7. Design and development of a high-power, 500 kV pulsed line

    International Nuclear Information System (INIS)

    Nicolas, A.

    A study was made of very high voltage (500 kV) pulse production for 50 ns at half height. A coaxial line was coupled to a Marx generator for obtaining the pulses on an impedance-adapted electron diode. The maximum power obtained was 6.4 x 10 10 W with a current front in the diode of about 30 ns (80 ns pulse length at half height)

  8. Frequency domain based LS channel estimation in OFDM based Power line communications

    OpenAIRE

    Bogdanović, Mario

    2015-01-01

    This paper is focused on low voltage power line communication (PLC) realization with an emphasis on channel estimation techniques. The Orthogonal Frequency Division Multiplexing (OFDM) scheme is preferred technology in PLC systems because of its effective combat with frequency selective fading properties of PLC channel. As the channel estimation is one of the crucial problems in OFDM based PLC system because of a problematic area of PLC signal attenuation and interference, the improved LS est...

  9. Termination for a superconducting power transmission line including a horizontal cryogenic bushing

    Science.gov (United States)

    Minati, Kurt F.; Morgan, Gerry H.; McNerney, Andrew J.; Schauer, Felix

    1984-01-01

    A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminates the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

  10. Survey of seismic conditions of drilling and blasting operations near overhead electricity power lines

    Science.gov (United States)

    Korshunov, G. I.; Afanasev, P. I.; Bulbasheva, I. A.

    2017-10-01

    The monitoring and survey results of drilling and blasting operations are specified during the development of Afanasyevsky deposit of cement raw materials for a 110 kV electricity power lines structure. Seismic explosion waves and air shock waves were registered in the course of monitoring. The dependency of peak particle velocities on the scaled distance and explosive weight by the delay time was obtained.

  11. Distributed power-line outage detection based on wide area measurement system.

    Science.gov (United States)

    Zhao, Liang; Song, Wen-Zhan

    2014-07-21

    In modern power grids, the fast and reliable detection of power-line outages is an important functionality, which prevents cascading failures and facilitates an accurate state estimation to monitor the real-time conditions of the grids. However, most of the existing approaches for outage detection suffer from two drawbacks, namely: (i) high computational complexity; and (ii) relying on a centralized means of implementation. The high computational complexity limits the practical usage of outage detection only for the case of single-line or double-line outages. Meanwhile, the centralized means of implementation raises security and privacy issues. Considering these drawbacks, the present paper proposes a distributed framework, which carries out in-network information processing and only shares estimates on boundaries with the neighboring control areas. This novel framework relies on a convex-relaxed formulation of the line outage detection problem and leverages the alternating direction method of multipliers (ADMM) for its distributed solution. The proposed framework invokes a low computational complexity, requiring only linear and simple matrix-vector operations. We also extend this framework to incorporate the sparse property of the measurement matrix and employ the LSQRalgorithm to enable a warm start, which further accelerates the algorithm. Analysis and simulation tests validate the correctness and effectiveness of the proposed approaches.

  12. Location of Faults in Power Transmission Lines Using the ARIMA Method

    Directory of Open Access Journals (Sweden)

    Danilo Pinto Moreira de Souza

    2017-10-01

    Full Text Available One of the major problems in transmission lines is the occurrence of failures that affect the quality of the electric power supplied, as the exact localization of the fault must be known for correction. In order to streamline the work of maintenance teams and standardize services, this paper proposes a method of locating faults in power transmission lines by analyzing the voltage oscillographic signals extracted at the line monitoring terminals. The developed method relates time series models obtained specifically for each failure pattern. The parameters of the autoregressive integrated moving average (ARIMA model are estimated in order to adjust the voltage curves and calculate the distance from the initial fault localization to the terminals. Simulations of the failures are performed through the ATPDraw ® (5.5 software and the analyses were completed using the RStudio ® (1.0.143 software. The results obtained with respect to the failures, which did not involve earth return, were satisfactory when compared with widely used techniques in the literature, particularly when the fault distance became larger in relation to the beginning of the transmission line.

  13. LINES

    Directory of Open Access Journals (Sweden)

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  14. Simulation Analysis of Transmission-Line Impedance Transformers for Petawatt-Class Pulsed Power Accelerators

    International Nuclear Information System (INIS)

    Hu Yixiang; Qiu Aici; Sun Fengju; Huang Tao; Cong Peitian; Wang Liangping; Zeng Jiangtao; Li Yan; Zhang Xinjun; Lei Tianshi

    2011-01-01

    Based on the transmission line code TLCODE, a 1D circuit model for a transmission-line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to quantify the efficiencies of voltage-transport, energy-transport and power-transport for a transmission-line impedance transformer as functions of ψ (the ratio of the output impedance to the input impedance of the transformer) and Γ (the ratio of the pulse width to the one-way transit time of the transformer) under a large scale of m (the coefficient of the generalized exponential impedance profile). Simulation results suggest that with the increase in Γ, from 0 to ∞, the power transport efficiency first increases and then decreases. The maximum power transport efficiency can reach 90% or even higher for an exponential impedance profile (m = 1). With a consideration of dissipative loss in the dielectric and electrodes of the transformer, two representative designs of the water-insulated transformer are investigated for the next generation of petawatt-class z-pinch drivers. It is found that the dissipative losses in the electrodes are negligibly small, below 0.1%, but the dissipative loss in the water dielectric is about 1% to 4%. (fusion engineering)

  15. AUTOMATED INSPECTION OF POWER LINE CORRIDORS TO MEASURE VEGETATION UNDERCUT USING UAV-BASED IMAGES

    Directory of Open Access Journals (Sweden)

    M. Maurer

    2017-08-01

    Full Text Available Power line corridor inspection is a time consuming task that is performed mostly manually. As the development of UAVs made huge progress in recent years, and photogrammetric computer vision systems became well established, it is time to further automate inspection tasks. In this paper we present an automated processing pipeline to inspect vegetation undercuts of power line corridors. For this, the area of inspection is reconstructed, geo-referenced, semantically segmented and inter class distance measurements are calculated. The presented pipeline performs an automated selection of the proper 3D reconstruction method for on the one hand wiry (power line, and on the other hand solid objects (surrounding. The automated selection is realized by performing pixel-wise semantic segmentation of the input images using a Fully Convolutional Neural Network. Due to the geo-referenced semantic 3D reconstructions a documentation of areas where maintenance work has to be performed is inherently included in the distance measurements and can be extracted easily. We evaluate the influence of the semantic segmentation according to the 3D reconstruction and show that the automated semantic separation in wiry and dense objects of the 3D reconstruction routine improves the quality of the vegetation undercut inspection. We show the generalization of the semantic segmentation to datasets acquired using different acquisition routines and to varied seasons in time.

  16. Automated Inspection of Power Line Corridors to Measure Vegetation Undercut Using Uav-Based Images

    Science.gov (United States)

    Maurer, M.; Hofer, M.; Fraundorfer, F.; Bischof, H.

    2017-08-01

    Power line corridor inspection is a time consuming task that is performed mostly manually. As the development of UAVs made huge progress in recent years, and photogrammetric computer vision systems became well established, it is time to further automate inspection tasks. In this paper we present an automated processing pipeline to inspect vegetation undercuts of power line corridors. For this, the area of inspection is reconstructed, geo-referenced, semantically segmented and inter class distance measurements are calculated. The presented pipeline performs an automated selection of the proper 3D reconstruction method for on the one hand wiry (power line), and on the other hand solid objects (surrounding). The automated selection is realized by performing pixel-wise semantic segmentation of the input images using a Fully Convolutional Neural Network. Due to the geo-referenced semantic 3D reconstructions a documentation of areas where maintenance work has to be performed is inherently included in the distance measurements and can be extracted easily. We evaluate the influence of the semantic segmentation according to the 3D reconstruction and show that the automated semantic separation in wiry and dense objects of the 3D reconstruction routine improves the quality of the vegetation undercut inspection. We show the generalization of the semantic segmentation to datasets acquired using different acquisition routines and to varied seasons in time.

  17. High Voltage Overhead Power Line Routing under an Objective Observability Criterion

    Directory of Open Access Journals (Sweden)

    L. Alfredo Fernandez-Jimenez

    2017-10-01

    Full Text Available The construction of new high voltage overhead power lines (HVOPLs has become a controversial issue for electricity companies due to social opposition. Citizens are concerned about how these power lines may have an impact on their lives, basically caused by their effects on health and safety. Visual impact is one of the most easily perceived. Although there are several published works that deal with the assessment of the visual impact produced by HVOPLs, no methodology has been proposed to assess this impact from an objective perspective. This work presents an original methodology which helps to identify the optimal routes for a new HVOPL under an objective observability criterion, enabling the selection of those with the lowest visibility in a zone. The application of the proposed methodology achieves a set of routes that links new HVOPL origin and destination points creating a corridor which includes all possible routes with an observability of its towers under a threshold limit. This methodology is illustrated by a real-life use corresponding to the selection of the route with least observability for a new power line in La Rioja (Spain. The results obtained may help to achieve a consensus between key stakeholders since it is focused on the specific issues of the planned HVOPL and its observability from an objective perspective.

  18. Alleviation SSR and Low Frequency Power Oscillations in Series Compensated Transmission Line using SVC Supplementary Controllers

    Science.gov (United States)

    Kumar, Sanjiv; Kumar, Narendra

    2017-06-01

    In this work, supplementary sub-synchronous damping controllers (SSDC) are proposed for damping sub-synchronous oscillations in power systems with series compensated transmission lines. Series compensation have extensively been used as effective means of increasing the power transfer capability of a transmission lines and improving transient stability limits of power systems. Series compensation with transmission lines may cause sub-synchronous resonance (SSR). The eigenvalue investigation tool is used to ascertain the existence of SSR. It is shown that the addition of supplementary controller is able to stabilize all unstable modes for T-network model. Eigenvalue investigation and time domain transient simulation of detailed nonlinear system are considered to investigate the performance of the controllers. The efficacies of the suggested supplementary controllers are compared on the IEEE first benchmark model for computer simulations of SSR by means of time domain simulation in Matlab/Simulink environment. Supplementary SSDC are considered in order to compare effectiveness of SSDC during higher loading in alleviating the small signal stability problem.

  19. Adapting AC Lines to DC Grids for Large-Scale Renewable Power Transmission

    Directory of Open Access Journals (Sweden)

    D. Marene Larruskain

    2014-10-01

    Full Text Available All over the world, governments of different countries are nowadays promoting the use of clean energies in order to achieve sustainable energy systems. In this scenario, since the installed capacity is continuously increasing, renewable sources can play an important role. Notwithstanding that, some important problems may appear when connecting these sources to the grid, being the overload of distribution lines one of the most relevant. In fact, renewable generation is usually connected to the nearest AC grid, although this HV system may not have been designed considering distributed generation. In the particular case of large wind farms, the electrical grid has to transmit all the power generated by wind energy and, as a consequence, the AC system may get overloaded. It is therefore necessary to determine the impact of wind power transmission so that appropriate measures can be taken. Not only are these measures influenced by the amount of power transmitted, but also by the quality of the transmitted power, due to the output voltage fluctuation caused by the highly variable nature of wind. When designing a power grid, although AC systems are usually the most economical solution because of its highly proven technology, HVDC may arise in some cases (e.g. offshore wind farms as an interesting alternative, offering some added values such as lower losses and better controllability. This way, HVDC technology can solve most of the aforementioned problems and has a good potential for future use. Additionally, the fast development of power electronics based on new and powerful semiconductor devices allow the spread of innovative technologies, such as VSC-HVDC, which can be applied to create DC grids. This paper focuses on the main aspects involved in adapting the existing overhead AC lines to DC grids, with the objective of improving the transmission of distributed renewable energy to the centers of consumption.

  20. On-line validation of feedwater flow rate in nuclear power plants using neural networks

    International Nuclear Information System (INIS)

    Khadem, M.; Ipakchi, A.; Alexandro, F.J.; Colley, R.W.

    1994-01-01

    On-line calibration of feedwater flow rate measurement in nuclear power plants provides a continuous realistic value of feedwater flow rate. It also reduces the manpower required for periodic calibration needed due to the fouling and defouling of the venturi meter surface condition. This paper presents a method for on-line validation of feedwater flow rate in nuclear power plants. The method is an improvement of the previously developed method which is based on the use of a set of process variables dynamically related to the feedwater flow rate. The online measurements of this set of variables are used as inputs to a neural network to obtain an estimate of the feedwater flow rate reading. The difference between the on-line feedwater flow rate reading, and the neural network estimate establishes whether there is a need to apply a correction factor to the feedwater flow rate measurement for calculation of the actual reactor power. The method was applied to the feedwater flow meters in the two feedwater flow loops of the TMI-1 nuclear power plant. The venturi meters used for flow measurements are susceptible to frequent fouling that degrades their measurement accuracy. The fouling effects can cause an inaccuracy of up to 3% relative error in feedwater flow rate reading. A neural network, whose inputs were the readings of a set of reference instruments, was designed to predict both feedwater flow rates simultaneously. A multi-layer feedforward neural network employing the backpropagation algorithm was used. A number of neural network training tests were performed to obtain an optimum filtering technique of the input/output data of the neural networks. The result of the selection of the filtering technique was confirmed by numerous Fast Fourier Transform (FFT) tests. Training and testing were done on data from TMI-1 nuclear power plant. The results show that the neural network can predict the correct flow rates with an absolute relative error of less than 2%

  1. Reviewing surveillance activities in nuclear power plants

    International Nuclear Information System (INIS)

    1989-03-01

    This document provides guidance to Operational Safety Review Teams (OSARTs) for reviewing surveillance activities at a nuclear power plant. In addition, the document contains reference material to support the review of surveillance activities, to assist within the Technical Support area and to ensure consistency between individual reviews. Drafts of the document have already been used on several OSART missions and found to be useful. The document first considers the objectives of an excellent surveillance programme. Investigations to determine the quality of the surveillance programme are then discussed. The attributes of an excellent surveillance programme are listed. Advice follows on how to phrase questions so as to obtain an informative response on surveillance features. Finally, specific equipment is mentioned that should be considered when reviewing functional tests. Four annexes provide examples drawn from operating nuclear power plants. They were selected to supplement the main text of the document with the best international practices as found in OSART reviews. They should in no way limit the acceptance and development of alternative approaches that lead to equivalent or better results. Refs, figs and tabs

  2. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels shunt Hybrid Active ...

  3. Active load sharing technique for on-line efficiency optimization in DC microgrids

    DEFF Research Database (Denmark)

    Sanseverino, E. Riva; Zizzo, G.; Boscaino, V.

    2017-01-01

    Recently, DC power distribution is gaining more and more importance over its AC counterpart achieving increased efficiency, greater flexibility, reduced volumes and capital cost. In this paper, a 24-120-325V two-level DC distribution system for home appliances, each including three parallel DC......-DC converters, is modeled. An active load sharing technique is proposed for the on-line optimization of the global efficiency of the DC distribution network. The algorithm aims at the instantaneous efficiency optimization of the whole DC network, based on the on-line load current sampling. A Look Up Table......, is created to store the real efficiencies of the converters taking into account components tolerances. A MATLAB/Simulink model of the DC distribution network has been set up and a Genetic Algorithm has been employed for the global efficiency optimization. Simulation results are shown to validate the proposed...

  4. Markerless tracking in nuclear power plants. A line segment-based approach

    International Nuclear Information System (INIS)

    Ishii, Hirotake; Kimura, Taro; Tokumaru, Hiroki; Shimoda, Hiroshi; Koda, Yuya

    2017-01-01

    To develop augmented reality-based support systems, a tracking method that measures the camera's position and orientation in real time is indispensable. A relocalization is one step that is used to (re)start the tracking. A line-segment-based relocalization method that uses a RGB-D camera and coarse-to-fine approach was developed and evaluated for this study. In the preparation stage, the target environment is scanned with a RGB-D camera. Line segments are recognized. Then three-dimensional positions of the line segments are calculated, and statistics of the line segments are calculated and stored in a database. In the relocalization stage, a few images that closely resemble the current RGB-D camera image are chosen from the database by comparing the statistics of the line segments. Then the most similar image is chosen using Normalized Cross-Correlation. This coarse-to-fine approach reduces the computational load to find the most similar image. The method was evaluated in the water purification room of the Fugen nuclear power plant. Results showed that the success rate of the relocalization is 93.6% and processing time is 45.7 ms per frame on average, which is promising for practical use. (author)

  5. Aerodynamic instability of cables in transmission power lines; Inestabilidad aerodinamica en cables de lineas de transmision

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Lopez, Alberto; Vilar Rojas, Jorge Ivan; Munoz Black, Celso J. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    One of the aerodynamic instabilities of transmission power lines cables is galloping, which consists in the appearance of important cable vibrations, mainly when the wind hits orthogonally the power line. In some cases the maximum amplitude that occurs reaches several meters, even when the wind velocities in a region are well below the value used for the mechanical design of the power lines. In general terms, galloping is associated with particular climatic conditions such as low temperatures and high humidities. In these conditions a coating of ice that adheres to the cable is formed, changing its transverse cross section, propitiating the galloping, although some authors have reported galloping without ice. These climatic conditions are presented mainly in the Northern part of our country and in the high regions of the mountain zones; nevertheless, the galloping phenomenon has been reported in few cases by Comision Federal de Electricidad (CFE). The possible expansion of the power lines in these regions of the country leads to prevent the measures needed to diminish the appearance of this phenomenon. In this paper mention is made in particular of the solution adopted to the galloping problem that has appeared in the transmission power line of Salamayuca to Reforma, Ciudad Juarez, Chihuahua (CFE,1991). [Espanol] Una de las inestabilidades aerodinamicas que se presentan en los cables de lineas de transmision es el galopeo, el cual consiste en la aparicion de vibraciones importantes de los cables, sobre todo cuando el flujo del viento incide ortogonalmente a la linea. En algunos casos las amplitudes maximas que se presentan llegan a ser de varios metros, aun cuando las velocidades del viento en una region esten muy por debajo del valor empleado para el diseno mecanico de las lineas. Generalmente, el galopeo se asocia con condiciones climaticas particulares como son las bajas temperaturas y altas humedades. En estas condiciones se forma una cubierta de hielo que se

  6. Aerodynamic instability of cables in transmission power lines; Inestabilidad aerodinamica en cables de lineas de transmision

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Lopez, Alberto; Vilar Rojas, Jorge Ivan; Munoz Black, Celso J [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    One of the aerodynamic instabilities of transmission power lines cables is galloping, which consists in the appearance of important cable vibrations, mainly when the wind hits orthogonally the power line. In some cases the maximum amplitude that occurs reaches several meters, even when the wind velocities in a region are well below the value used for the mechanical design of the power lines. In general terms, galloping is associated with particular climatic conditions such as low temperatures and high humidities. In these conditions a coating of ice that adheres to the cable is formed, changing its transverse cross section, propitiating the galloping, although some authors have reported galloping without ice. These climatic conditions are presented mainly in the Northern part of our country and in the high regions of the mountain zones; nevertheless, the galloping phenomenon has been reported in few cases by Comision Federal de Electricidad (CFE). The possible expansion of the power lines in these regions of the country leads to prevent the measures needed to diminish the appearance of this phenomenon. In this paper mention is made in particular of the solution adopted to the galloping problem that has appeared in the transmission power line of Salamayuca to Reforma, Ciudad Juarez, Chihuahua (CFE,1991). [Espanol] Una de las inestabilidades aerodinamicas que se presentan en los cables de lineas de transmision es el galopeo, el cual consiste en la aparicion de vibraciones importantes de los cables, sobre todo cuando el flujo del viento incide ortogonalmente a la linea. En algunos casos las amplitudes maximas que se presentan llegan a ser de varios metros, aun cuando las velocidades del viento en una region esten muy por debajo del valor empleado para el diseno mecanico de las lineas. Generalmente, el galopeo se asocia con condiciones climaticas particulares como son las bajas temperaturas y altas humedades. En estas condiciones se forma una cubierta de hielo que se

  7. A new algorithm for optimum voltage and reactive power control for minimizing transmission lines losses

    International Nuclear Information System (INIS)

    Ghoudjehbaklou, H.; Danai, B.

    2001-01-01

    Reactive power dispatch for voltage profile modification has been of interest to power utilities. Usually local bus voltages can be altered by changing generator voltages, reactive shunts, ULTC transformers and SVCs. Determination of optimum values for control parameters, however, is not simple for modern power system networks. Heuristic and rather intelligent algorithms have to be sought. In this paper a new algorithm is proposed that is based on a variant of a genetic algorithm combined with simulated annealing updates. In this algorithm a fuzzy multi-objective a approach is used for the fitness function of the genetic algorithm. This fuzzy multi-objective function can efficiently modify the voltage profile in order to minimize transmission lines losses, thus reducing the operating costs. The reason for such a combination is to utilize the best characteristics of each method and overcome their deficiencies. The proposed algorithm is much faster than the classical genetic algorithm and cna be easily integrated into existing power utilities software. The proposed algorithm is tested on an actual system model of 1284 buses, 799 lines, 1175 fixed and ULTC transformers, 86 generators, 181 controllable shunts and 425 loads

  8. The effects of lightning and high altitude electromagnetic pulse on power distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Uman, M.A.; Rubinstein, M.; Yacoub, Z. [Florida Univ., Gainesville, FL (United States)

    1995-01-01

    We simultaneously recorded the voltages induced by lightning on both ends of an unenergized 448-meter long unenergized electric power line and the lightning vertical electric and horizontal magnetic fields at ground level near the line. The lightning data studied and presented here were due both to cloud lightning and to very close (about 20 m from the line) artificially initiated lightning. For cloud sources, a frequency-domain computer program called EMPLIN was used to calculate induced line voltages as a function of source elevation, angle of incidence, and wave polarization of the radiated cloud discharge pulses in order to compare with the measurements. For very-close lightning, the measured line voltages could be grouped into two categories, those in which multiple, similarly shaped, evenly spaced pulses were observed, which we call oscillatory, and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which we call impulsive. The amplitude of the induced voltage ranged from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages. A new technique is derived for the calculation of the electromagnetic fields from nearby lightning to ground above an imperfectly conducting ground. This technique was used in conjunction with an existing time domain coupling theory and lightning return stroke model to calculate voltages at either end of the line. The results show fair agreement with the measured oscillatory voltage waveforms if corona is ignored and improved results when corona effects are modeled. The modeling of the impulsive voltage, for which local flashover probably successful. In an attempt to understand better the sources of the line voltages for very close lightning, measurements of the horizontal and vertical electric fields 30 m from triggered lightning were obtained.

  9. Analysis methodology for the post-trip return to power steam line break event

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chul Shin; Kim, Chul Woo; You, Hyung Keun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-06-01

    An analysis for Steam Line Break (SLB) events which result in a Return-to-Power (RTP) condition after reactor trip was performed for a postulated Yonggwang Nuclear Power Plant Unit 3 cycle 8. Analysis methodology for post-trip RTP SLB is quite different from that of non-RTP SLB and is more difficult. Therefore, it is necessary to develop a methodology to analyze the response of the NSSS parameters to the post-trip RTP SLB events and the fuel performance after the total reactivity exceeds the criticality. In this analysis, the cases with and without offsite power were simulated crediting 3-D reactivity feedback effect due to a local heatup in the vicinity of stuck CEA and compared with the cases without 3-D reactivity feedback with respect to post-trip fuel performance. Departure-to Nucleate Boiling Ratio (DNBR) and Linear Heat Generation Rate (LHGR). 36 tabs., 32 figs., 11 refs. (Author) .new.

  10. Evaluation of the Harmonic Impedance of Frydlant (Line 53 Power Network

    Directory of Open Access Journals (Sweden)

    Shehab Abdulwadood Ali

    2013-01-01

    Full Text Available The harmonic impedance of the power system is an important quantity, which describes the behaviour of the power system with the existence of different frequencies beside the fundamental. The harmonic study belongs to the most difficult part of the electrical measurements and calculations even by using computer software. The main problem accompanying the calculating methods is to obtain the exact data of the electrical network parameters or to know the exact operational status of the system. In this paper the harmonic impedance of Frydlant (line 53, 22~kV in Czech Republic power network was calculated by using a very specialized software and suitable for solving such calculations called "NetCalc. version 3.0" [1].

  11. LCL filter design for three-phase two-level power factor correction using line impedance stabilization network

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2016-01-01

    This paper presents LCL filter design method for three-phase two-level power factor correction (PFC) using line impedance stabilization network (LISN). A straightforward LCL filter design along with variation in grid impedance is not simply achievable and inevitably lead to an iterative solution...... for filter. By introducing of fast power switches for PFC applications such as silicon-carbide, major current harmonics around the switching frequency drops in the region that LISN can actively provide well-defined impedance for measuring the harmonics (i.e. 9 kHz- 30MHz). Therefore, LISN can be replaced...... is derived using the current ripple behavior of converter-side inductor. The grid-side inductor is achieved as a function of LISN impedance to fulfill the grid regulation. To verify the analyses, an LCL filter is designed for a 5 kW SiC-based PFC. The simulation and experimental results support the validity...

  12. Virtual solar field - An opportunity to optimize transient processes in line-focus CSP power plants

    Science.gov (United States)

    Noureldin, Kareem; Hirsch, Tobias; Pitz-Paal, Robert

    2017-06-01

    Optimizing solar field operation and control is a key factor to improve the competitiveness of line-focus solar thermal power plants. However, the risks of assessing new and innovative control strategies on operational power plants hinder such optimizations and result in applying more conservative control schemes. In this paper, we describe some applications for a whole solar field transient in-house simulation tool developed at the German Aerospace Centre (DLR), the Virtual Solar Field (VSF). The tool offers a virtual platform to simulate real solar fields while coupling the thermal and hydraulic conditions of the field with high computational efficiency. Using the tool, developers and operator can probe their control strategies and assess the potential benefits while avoiding the high risks and costs. In this paper, we study the benefits gained from controlling the loop valves and of using direct normal irradiance maps and forecasts for the field control. Loop valve control is interesting for many solar field operators since it provides a high degree of flexibility to the control of the solar field through regulating the flow rate in each loop. This improves the reaction to transient condition, such as passing clouds and field start-up in the morning. Nevertheless, due to the large number of loops and the sensitivity of the field control to the valve settings, this process needs to be automated and the effect of changing the setting of each valve on the whole field control needs to be taken into account. We used VSF to implement simple control algorithms to control the loop valves and to study the benefits that could be gained from using active loop valve control during transient conditions. Secondly, we study how using short-term highly spatially-resolved DNI forecasts provided by cloud cameras could improve the plant energy yield. Both cases show an improvement in the plant efficiency and outlet temperature stability. This paves the road for further

  13. Nuclear Power and Safety Division activity

    International Nuclear Information System (INIS)

    Pazdera, F.

    1991-01-01

    History of the Division is briefly described. Present research is centered on reliability analyses and thermal hydraulic analyses of transients and accidents. Some results of the safety analyses have been applied at nuclear power plants. A characterization is presented of computer codes for analyzing the behavior of fuel in normal and accident conditions. Research activities in the field of water chemistry and corrosion are oriented to the corrosion process at high temperatures and high pressures, and the related mass and radioactivity transfer; the effect of some chemical processes on primary coolant circuit materials; optimization of PWR filtration systems; and the development of the requisite monitoring instrumentation. A computerized operator support system has been developed, and at present it is tested at the Dukovany nuclear power plant. A program of nuclear fuel cycle strategy and economy has been worked out for nuclear fuel performance evaluation. Various options for better fuel exploitation, alternatives for advanced fuelling, and fuel cycle costs are assessed, and out-of-reactor fuel cycle options are compared. (M.D.). 7 refs., 32 refs

  14. Wind Powering America FY07 Activities Summary

    Energy Technology Data Exchange (ETDEWEB)

    2008-02-01

    The Wind Powering America FY07 Activities Summary reflects the accomplishments of our state wind working groups, our programs at the National Renewable Energy Laboratory, and our partner organizations. The national WPA team remains a leading force for moving wind energy forward in the United States. WPA continues to work with its national, regional, and state partners to communicate the opportunities and benefits of wind energy to a diverse set of stakeholders. WPA now has 30 state wind working groups (welcoming Georgia and Wisconsin in 2007) that form strategic alliances to communicate wind's benefits to the state stakeholders. More than 140 members of national and state public and private sector organizations from 39 U.S. states and Canada attended the 6th Annual WPA All-States Summit in Los Angeles in June. WPA's emphasis remains on the rural agricultural sector, which stands to reap the significant economic development benefits of wind energy development. Additionally, WPA continues its program of outreach, education, and technical assistance to Native American communities, public power entities, and regulatory and legislative bodies.

  15. Wind Powering America FY06 Activities Summary

    Energy Technology Data Exchange (ETDEWEB)

    2007-02-01

    The Wind Powering America FY06 Activities Summary reflects the accomplishments of our state wind working groups, our programs at the National Renewable Energy Laboratory, and our partner organizations. The national WPA team remains a leading force for moving wind energy forward in the United States. WPA continues to work with its national, regional, and state partners to communicate the opportunities and benefits of wind energy to a diverse set of stakeholders. WPA now has 29 state wind working groups (welcoming New Jersey, Indiana, Illinois, and Missouri in 2006) that form strategic alliances to communicate wind's benefits to the state stakeholders. More than 120 members of national and state public and private sector organizations from 34 states attended the 5th Annual WPA All-States Summit in Pittsburgh in June.

  16. Rapid Active Power Control of Photovoltaic Systems for Grid Frequency Support

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Shirazi, Mariko; Chakraborty, Sudipta; Muljadi, Eduard; Maksimovic, Dragan

    2017-01-01

    As deployment of power electronic coupled generation such as photovoltaic (PV) systems increases, grid operators have shown increasing interest in calling on inverter-coupled generation to help mitigate frequency contingency events by rapidly surging active power into the grid. When responding to contingency events, the faster the active power is provided, the more effective it may be for arresting the frequency event. This paper proposes a predictive PV inverter control method for very fast and accurate control of active power. This rapid active power control method will increase the effectiveness of various higher-level controls designed to mitigate grid frequency contingency events, including fast power-frequency droop, inertia emulation, and fast frequency response, without the need for energy storage. The rapid active power control method, coupled with a maximum power point estimation method, is implemented in a prototype PV inverter connected to a PV array. The prototype inverter's response to various frequency events is experimentally confirmed to be fast (beginning within 2 line cycles and completing within 4.5 line cycles of a severe test event) and accurate (below 2% steady-state error).

  17. Adaptive on-line prediction of the available power of lithium-ion batteries

    Science.gov (United States)

    Waag, Wladislaw; Fleischer, Christian; Sauer, Dirk Uwe

    2013-11-01

    In this paper a new approach for prediction of the available power of a lithium-ion battery pack is presented. It is based on a nonlinear battery model that includes current dependency of the battery resistance. It results in an accurate power prediction not only at room temperature, but also at lower temperatures at which the current dependency is substantial. The used model parameters are fully adaptable on-line to the given state of the battery (state of charge, state of health, temperature). This on-line adaption in combination with an explicit consideration of differences between characteristics of individual cells in a battery pack ensures an accurate power prediction under all possible conditions. The proposed trade-off between the number of used cell parameters and the total accuracy as well as the optimized algorithm results in a real-time capability of the method, which is demonstrated on a low-cost 16 bit microcontroller. The verification tests performed on a software-in-the-loop test bench system with four 40 Ah lithium-ion cells show promising results.

  18. Wet snow hazard for power lines: a forecast and alert system applied in Italy

    Directory of Open Access Journals (Sweden)

    P. Bonelli

    2011-09-01

    Full Text Available Wet snow icing accretion on power lines is a real problem in Italy, causing failures on high and medium voltage power supplies during the cold season. The phenomenon is a process in which many large and local scale variables contribute in a complex way and not completely understood. A numerical weather forecast can be used to select areas where wet snow accretion has an high probability of occurring, but a specific accretion model must also be used to estimate the load of an ice sleeve and its hazard. All the information must be carefully selected and shown to the electric grid operator in order to warn him promptly.

    The authors describe a prototype of forecast and alert system, WOLF (Wet snow Overload aLert and Forecast, developed and applied in Italy. The prototype elaborates the output of a numerical weather prediction model, as temperature, precipitation, wind intensity and direction, to determine the areas of potential risk for the power lines. Then an accretion model computes the ice sleeves' load for different conductor diameters. The highest values are selected and displayed on a WEB-GIS application principally devoted to the electric operator, but also to more expert users. Some experimental field campaigns have been conducted to better parameterize the accretion model. Comparisons between real accidents and forecasted icing conditions are presented and discussed.

  19. Wet snow hazard for power lines: a forecast and alert system applied in Italy

    Science.gov (United States)

    Bonelli, P.; Lacavalla, M.; Marcacci, P.; Mariani, G.; Stella, G.

    2011-09-01

    Wet snow icing accretion on power lines is a real problem in Italy, causing failures on high and medium voltage power supplies during the cold season. The phenomenon is a process in which many large and local scale variables contribute in a complex way and not completely understood. A numerical weather forecast can be used to select areas where wet snow accretion has an high probability of occurring, but a specific accretion model must also be used to estimate the load of an ice sleeve and its hazard. All the information must be carefully selected and shown to the electric grid operator in order to warn him promptly. The authors describe a prototype of forecast and alert system, WOLF (Wet snow Overload aLert and Forecast), developed and applied in Italy. The prototype elaborates the output of a numerical weather prediction model, as temperature, precipitation, wind intensity and direction, to determine the areas of potential risk for the power lines. Then an accretion model computes the ice sleeves' load for different conductor diameters. The highest values are selected and displayed on a WEB-GIS application principally devoted to the electric operator, but also to more expert users. Some experimental field campaigns have been conducted to better parameterize the accretion model. Comparisons between real accidents and forecasted icing conditions are presented and discussed.

  20. Impact evaluation of conducted UWB transients on loads in power-line networks

    Science.gov (United States)

    Li, Bing; Månsson, Daniel

    2017-09-01

    Nowadays, faced with the ever-increasing dependence on diverse electronic devices and systems, the proliferation of potential electromagnetic interference (EMI) becomes a critical threat for reliable operation. A typical issue is the electronics working reliably in power-line networks when exposed to electromagnetic environment. In this paper, we consider a conducted ultra-wideband (UWB) disturbance, as an example of intentional electromagnetic interference (IEMI) source, and perform the impact evaluation at the loads in a network. With the aid of fast Fourier transform (FFT), the UWB transient is characterized in the frequency domain. Based on a modified Baum-Liu-Tesche (BLT) method, the EMI received at the loads, with complex impedance, is computed. Through inverse FFT (IFFT), we obtain time-domain responses of the loads. To evaluate the impact on loads, we employ five common, but important quantifiers, i.e., time-domain peak, total signal energy, peak signal power, peak time rate of change and peak time integral of the pulse. Moreover, to perform a comprehensive analysis, we also investigate the effects of the attributes (capacitive, resistive, or inductive) of other loads connected to the network, the rise time and pulse width of the UWB transient, and the lengths of power lines. It is seen that, for the loads distributed in a network, the impact evaluation of IEMI should be based on the characteristics of the IEMI source, and the network features, such as load impedances, layout, and characteristics of cables.

  1. Cryogenic Fiber Optic Sensors for Superconducting Magnets and Power Transmission Lines in High Energy Physics Applications

    CERN Document Server

    AUTHOR|(CDS)2081689; Bajko, Marta

    In the framework of the Luminosity upgrade of the Large Hadron Collider (HL - LHC), a remarkable R&D effort is now ongoing at the European Organization for Nuclear Research (CERN) in order to develop a new generation of accelerator magnets and superconducting power transmission lines. The magnet technology will be based on Nb$_{3}$Sn enabling to operate in the 11 - 13 T range. In parallel, in order to preserve the power converters from the increasing radiation level, high power transmission lines are foreseen to feed the magnets from free - radiation zones. These will be based on high temperature superconductors cooled down with helium gas in the range 5 - 30 K. The new technologies will require advanced design and fabrication approaches as well as adapted instrumentation for monitoring both the R&D phase and operation. Resistive sensors have been used so far for voltage, temperature and strain monitoring but their integration still suffers from the number of electrical wires and the complex compensat...

  2. On-line Monitoring and Calibration Techniques in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    2011-01-01

    Years of research, testing and experience in the field of sensor diagnostics have yielded many technologies which offer financial as well as operational benefits to the nuclear industry. Among these technologies are On-Line Monitoring (OLM) and On-Line Calibration of critical process monitoring sensors such as resistance temperature detectors (RTD), thermocouples, and pressure transmitters to name a few. The remote access and verification of these sensors have been shown to limit the exposure of maintenance personnel to harsh environments while at the same time effectively and efficiently diagnosing the health and performance of these sensors. In addition to sensors, technologies exist in determining not only the health of instrumentation and control (I and C) cabling that carries the signals from these sensors, but also these same cable testing techniques can be used in the remote evaluation of many end devices used in safety related operations as well. Given these advances in sensor system monitoring techniques it would seem to follow that nuclear utilities from around the world would be applying these tried and true techniques to optimize up time and to provide additional confidence in the output of processing sensors. However, although several of the world's regulatory bodies have approved of the concept of these techniques, few utilities have undertaken to fully embrace on-line monitoring and on-line calibration of nuclear process sensors. In the United States efforts are now underway, with representatives of the U.S. nuclear industry and nuclear power plant vendors to obtain generic NRC licensing for the use of OLM in nuclear power plants. If approved, generic licensing will help pave the way toward greater implementation of OLM and its related calibration techniques. (author)

  3. Solving Man-Induced Large-Scale Conservation Problems: The Spanish Imperial Eagle and Power Lines

    Science.gov (United States)

    López-López, Pascual; Ferrer, Miguel; Madero, Agustín; Casado, Eva; McGrady, Michael

    2011-01-01

    Background Man-induced mortality of birds caused by electrocution with poorly-designed pylons and power lines has been reported to be an important mortality factor that could become a major cause of population decline of one of the world rarest raptors, the Spanish imperial eagle (Aquila adalberti). Consequently it has resulted in an increasing awareness of this problem amongst land managers and the public at large, as well as increased research into the distribution of electrocution events and likely mitigation measures. Methodology/Principal Findings We provide information of how mitigation measures implemented on a regional level under the conservation program of the Spanish imperial eagle have resulted in a positive shift of demographic trends in Spain. A 35 years temporal data set (1974–2009) on mortality of Spanish imperial eagle was recorded, including population censuses, and data on electrocution and non-electrocution of birds. Additional information was obtained from 32 radio-tracked young eagles and specific field surveys. Data were divided into two periods, before and after the approval of a regional regulation of power line design in 1990 which established mandatory rules aimed at minimizing or eliminating the negative impacts of power lines facilities on avian populations. Our results show how population size and the average annual percentage of population change have increased between the two periods, whereas the number of electrocuted birds has been reduced in spite of the continuous growing of the wiring network. Conclusions Our results demonstrate that solving bird electrocution is an affordable problem if political interest is shown and financial investment is made. The combination of an adequate spatial planning with a sustainable development of human infrastructures will contribute positively to the conservation of the Spanish imperial eagle and may underpin population growth and range expansion, with positive side effects on other endangered

  4. Promising lines of investigations in the realms of laboratory astrophysics with the aid of powerful lasers

    International Nuclear Information System (INIS)

    Belyaev, V. S.; Batishchev, P. A.; Bolshakov, V. V.; Elkin, K. S.; Karabadzhak, G. F.; Kovkov, D. V.; Matafonov, A. P.; Raykunov, G. G.; Yakhin, R. A.; Pikuz, S. A.; Skobelev, I. Yu.; Faenov, A. Ya.; Fortov, V. E.; Krainov, V. P.; Rozanov, V. B.

    2013-01-01

    The results of work on choosing and substantiating promising lines of research in the realms of laboratory astrophysics with the aid of powerful lasers are presented. These lines of research are determined by the possibility of simulating, under laboratory conditions, problematic processes of presentday astrophysics, such as (i) the generation and evolution of electromagnetic fields in cosmic space and the role of magnetic fields there at various spatial scales; (ii) the mechanisms of formation and evolution of cosmic gamma-ray bursts and relativistic jets; (iii) plasma instabilities in cosmic space and astrophysical objects, plasma jets, and shock waves; (iv) supernova explosions and mechanisms of the explosion of supernovae featuring a collapsing core; (v) nuclear processes in astrophysical objects; (vi) cosmic rays and mechanisms of their production and acceleration to high energies; and (vii) astrophysical sources of x-ray radiation. It is shown that the use of existing powerful lasers characterized by an intensity in the range of 10 18 –10 22 W/cm 2 and a pulse duration of 0.1 to 1 ps and high-energy lasers characterized by an energy in excess of 1 kJ and a pulse duration of 1 to 10 ns makes it possible to perform investigations in laboratory astrophysics along all of the chosen promising lines. The results obtained by experimentally investigating laser plasma with the aid of the laser facility created at Central Research Institute of Machine Building (TsNIIMash) and characterized by a power level of 10 TW demonstrate the potential of such facilities for performing a number of experiments in the realms of laboratory astrophysics.

  5. Application of Computer Systems of Dynamic Modeling for Evaluation of Protection Behavior of Electric Power Lines

    Directory of Open Access Journals (Sweden)

    F. A. Romaniouk

    2008-01-01

    Full Text Available The paper considers problems pertaining to mathematical modeling of a transformer substation with protected electric power lines. It is proposed to use systems of dynamic modeling for investigations applying a method of calculative experiment with the purpose to evaluate behavior of protection and automation at short circuits. The paper contains comparison of results obtained with the help of program-simulated complex on the basis of a complex mathematical model of an object and with the help of dynamic modeling system – MathLab.

  6. Inductive coupling between overhead power lines and nearby metallic pipelines. A neural network approach

    Directory of Open Access Journals (Sweden)

    Levente Czumbil

    2015-12-01

    Full Text Available The current paper presents an artificial intelligence based technique applied in the investigation of electromagnetic interference problems between high voltage power lines (HVPL and nearby underground metallic pipelines (MP. An artificial neural network (NN solution has been implemented by the authors to evaluate the inductive coupling between HVPL and MP for different constructive geometries of an electromagnetic interference problem considering a multi-layer soil structure. Obtained results are compared to solutions provided by a finite element method (FEM based analysis and considered as reference. The advantage of the proposed method yields in a simplified computation model compared to FEM, and implicitly a lower computational time.

  7. Numerical study of electron-leakage power loss in a tri-plate transmission line

    International Nuclear Information System (INIS)

    Barker, R.J.; Goldstein, S.A.

    1982-01-01

    Numerical simulations have been conducted using NRL's DIODE2D computer code to model the steady-state behavior of electron flow in a radial diode and in its adjacent tri-plate transmission line (TTL). Particular attention was paid to the magnitude of the electron current flowing from the cathode to the anode surface in the TTL. A quantitative value for this effective power loss is given. The electron current is restricted mainly to the transition region in the TTL into which there is seepage of the B/sub z/ that is imposed in the diode gap. This finding highlights the importance of that region to diode designers

  8. A Simplified Control Method for Tie-Line Power of DC Micro-Grid

    OpenAIRE

    Yanbo Che; Jinhuan Zhou; Tingjun Lin; Wenxun Li; Jianmei Xu

    2018-01-01

    Compared with the AC micro-grid, the DC micro-grid has low energy loss and no issues of frequency stability, which makes it more accessible for distributed energy. Thus, the DC micro-grid has good potential for development. A variety of renewable energy is included in the DC micro-grid, which is easily affected by the environment, causing fluctuation of the DC voltage. For grid-connected DC micro-grid with droop control strategy, the tie-line power is affected by fluctuations in the DC voltag...

  9. Direct HST Dust Lane Detection in Powerful Narrow-Line Radio Galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Ramírez, Edgar A.; Aretxaga, Itziar [Instituto Nacional de Astrofísica, Óptica y Electrónica, Puebla (Mexico); Tadhunter, Clive N. [Department of Physics and Astronomy, University of Sheffield, Sheffield (United Kingdom); Lopez-Rodriguez, Enrique [NASA Ames Research Center, SOFIA Science Center, SOFIA/USRA, Mountain View, CA (United States); Department of Astronomy, University of Texas at Austin, Austin, TX (United States); McDonald Observatory, University of Texas at Austin, Austin, TX (United States); Packham, Chris, E-mail: e.ramirez@inaoep.mx [Department of Physics and Astronomy, University of Texas at San Antonio, San Antonio, TX (United States); National Astronomical Observatory of Japan, Tokyo (Japan)

    2017-11-22

    We present the analysis of near-infrared Hubble Space Telescope imaging of 10 Fanaroff Riley II powerful radio galaxies at low redshift (0.03 < z < 0.11) optically classified as narrow-line radio galaxies. The photometric properties of the host galaxy are measured using galfit, and compared with those from the literature. Our high resolution near-infrared observations provide new and direct information on the central kpc-scale dust lanes in our sample that could be connected to the pc-scale torus structure. Moreover, analyzing the infrared spectrograph Spitzer spectra of our sample, we suggest properties of the dust size of the torus.

  10. Line filter design of parallel interleaved VSCs for high power wind energy conversion systems

    DEFF Research Database (Denmark)

    Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand; Teodorescu, Remus

    2015-01-01

    The Voltage Source Converters (VSCs) are often connected in parallel in a Wind Energy Conversion System (WECS) to match the high power rating of the modern wind turbines. The effect of the interleaved carriers on the harmonic performance of the parallel connected VSCs is analyzed in this paper...... limit. In order to achieve the desired filter performance with optimal values of the filter parameters, the use of a LC trap branch with the conventional LCL filter is proposed. The expressions for the resonant frequencies of the proposed line filter are derived and used in the design to selectively...

  11. Audio-frequency noise emissions from high-voltage overhead power lines

    International Nuclear Information System (INIS)

    Semmler, M.; Straumann, U.; Roero, C.; Teich, T. H.

    2005-01-01

    This article discusses the noise-emissions caused by high-voltage overhead power lines that can occur under certain atmospheric conditions. These emissions, caused by electric discharges around the conductors, can achieve disturbing values, depending on the conditions prevailing at the time in question. The causes of the discharges are examined and the ionisation processes involved are looked at. The parameters influencing the discharges are discussed and measures that can be taken to reduce such audio-frequency emissions are looked at. The authors note that a reduction of peripheral field strengths can reduce emissions and that hydrophilic coatings can lead to faster reduction of such effects after rainfall

  12. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    Science.gov (United States)

    Hutsel, B. T.; Corcoran, P. A.; Cuneo, M. E.; Gomez, M. R.; Hess, M. H.; Hinshelwood, D. D.; Jennings, C. A.; Laity, G. R.; Lamppa, D. C.; McBride, R. D.; Moore, J. K.; Myers, A.; Rose, D. V.; Slutz, S. A.; Stygar, W. A.; Waisman, E. M.; Welch, D. R.; Whitney, B. A.

    2018-03-01

    We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-energy-storage capacitor, laser-triggered gas switch, pulse-forming line, self-break water switches, and tri-plate transmission lines. The circuit model also includes elements that represent Zs water convolute, vacuum insulator stack, four parallel outer magnetically insulated vacuum transmission lines (MITLs), double-post-hole vacuum convolute, inner vacuum MITL, and physics load. Within the vacuum-transmission-line system the model conducts analytic calculations of current loss. To calculate the loss, the model simulates the following processes: (i) electron emission from MITL cathode surfaces wherever an electric-field threshold has been exceeded; (ii) electron loss in the MITLs before magnetic insulation has been established; (iii) flow of electrons emitted by the outer-MITL cathodes after insulation has been established; (iv) closure of MITL anode-cathode (AK) gaps due to expansion of cathode plasma; (v) energy loss to MITL conductors operated at high lineal current densities; (vi) heating of MITL-anode surfaces due to conduction current and deposition of electron kinetic energy; (vii) negative-space-charge-enhanced ion emission from MITL anode surfaces wherever an anode-surface-temperature threshold has been exceeded; and (viii) closure of MITL AK gaps due to expansion of anode plasma. The circuit model is expected to be most accurate when the fractional current loss is small. We have performed circuit simulations of 52 Z experiments conducted with a variety of accelerator

  13. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    Directory of Open Access Journals (Sweden)

    B. T. Hutsel

    2018-03-01

    Full Text Available We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-energy-storage capacitor, laser-triggered gas switch, pulse-forming line, self-break water switches, and tri-plate transmission lines. The circuit model also includes elements that represent Zs water convolute, vacuum insulator stack, four parallel outer magnetically insulated vacuum transmission lines (MITLs, double-post-hole vacuum convolute, inner vacuum MITL, and physics load. Within the vacuum-transmission-line system the model conducts analytic calculations of current loss. To calculate the loss, the model simulates the following processes: (i electron emission from MITL cathode surfaces wherever an electric-field threshold has been exceeded; (ii electron loss in the MITLs before magnetic insulation has been established; (iii flow of electrons emitted by the outer-MITL cathodes after insulation has been established; (iv closure of MITL anode-cathode (AK gaps due to expansion of cathode plasma; (v energy loss to MITL conductors operated at high lineal current densities; (vi heating of MITL-anode surfaces due to conduction current and deposition of electron kinetic energy; (vii negative-space-charge-enhanced ion emission from MITL anode surfaces wherever an anode-surface-temperature threshold has been exceeded; and (viii closure of MITL AK gaps due to expansion of anode plasma. The circuit model is expected to be most accurate when the fractional current loss is small. We have performed circuit simulations of 52 Z experiments conducted with a

  14. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels ...

  15. Design and manufacture of the RF power supply and RF transmission line for SANAEM project Prometheus

    Science.gov (United States)

    Turemen, G.; Ogur, S.; Ahiska, F.; Yasatekin, B.; Cicek, E.; Ozbey, A.; Kilic, I.; Unel, G.; Alacakir, A.

    2017-08-01

    A 1-5 MeV proton beamline is being built by the Turkish Atomic Energy Authority in collaboration with a number of graduate students from different universities. The primary goal of the project, is to acquire the design ability and manufacturing capability of all the components locally. SPP will be an accelerator and beam diagnostics test facility and it will also serve the detector development community with its low beam current. This paper discusses the design and construction of the RF power supply and the RF transmission line components such as its waveguide converters and its circulator. Additionally low and high power RF test results are presented to compare the performances of the locally produced components to the commercially available ones.

  16. Diagnosis and on-line displacement monitoring for critical pipe of fossil power plant

    Energy Technology Data Exchange (ETDEWEB)

    Heo, J. S.; Hyun, J. S. [Korea Electric Power Corporation, Seoul (Korea, Republic of); Heo, J. R.; Lee, S. K.; Cho, S. Y. [Korea South-East Power Co., Ltd., Seoul (Korea, Republic of)

    2009-07-01

    High temperature steam pipes of fossil power plant are subject to a severe thermal range and usually operates well into the creep range. Cyclic operation of the plant subjects the piping system to mechanical and thermal fatigue mechanisms and poor or malfunctional support assemblies can impose massive loads or stress onto the piping system. In order to prevent the serious damage and failure of the critical pipe system, various inspection methods such as visual inspection, computational analysis and on-line piping displacement monitoring were developed. 3-Dimensional piping displacement monitoring system was developed with using he aluminum alloy rod and rotary encoder type sensors, this system was installed and operated on the 'Y' fossil power plant successfully. It is expected that this study will contribute to the safety of piping system, which could minimize stress and extend the actual life of critical piping.

  17. The Circulation Distribution on the Lifting Line for a Given Extracted Power

    Directory of Open Access Journals (Sweden)

    Ali Helali

    2012-01-01

    Full Text Available Presently, there exist few numerical methods which treat the inverse problem for the determination of the geometry of wind turbine blades. In this work, authors intend to solve the inverse optimum project for horizontal axis wind turbine in which the selection of the circulation distribution is obtained by resolving two variational problems: the first consists in sorting the circulation distribution on the lifting line, which, for a given power extracted by the wind turbine, minimizes the loses due to the induced velocity. In the second, the optimal circulation distribution is selected such that the kinetic energy of the wind downstream of the rotor disc is minimum, when the energy extracted by the wind turbine for one rotating period is imposed. A code has been developed which incorporates the real pitch of the helicoidal vortex wake. Very promising results have been obtained: the circulation distribution for a given extracted power and the chord lengths distribution law along the blade span.

  18. Optimized transmission-line impedance transformers for petawatt-class pulsed-power accelerators

    Directory of Open Access Journals (Sweden)

    D. R. Welch

    2008-03-01

    Full Text Available We have developed 1D analytic and 2D fully electromagnetic models of radial transmission-line impedance transformers. The models have been used to quantify the power-transport efficiency and pulse sharpening of such transformers as a function of voltage pulse width and impedance profile. For the cases considered, we find that in the limit as Γ→0 (where Γ is the ratio of the pulse width to the one-way transit time of the transformer, the transport efficiency is maximized when the impedance profile is exponential. As Γ increases from zero, the optimum profile gradually deviates from an exponential. A numerical procedure is presented that determines the optimum profile for a given pulse shape and width. The procedure can be applied to optimize the design of impedance transformers used in petawatt-class pulsed-power accelerators.

  19. Westinghouse Electric Company experiences in chemistry on-line monitoring in Eastern European nuclear power plants

    International Nuclear Information System (INIS)

    Balavage, J.

    2001-01-01

    Westinghouse Electric Company has provided a number of Chemistry On-Line Monitoring (OLM) Systems to Nuclear Power Plants in Eastern Europe. Eleven systems were provided to the Temelin Nuclear Power Plant in the south of the Czech Republic. Four systems were provided to the Russian NPP at Novovoronezh. In addition, a system design was developed for primary side chemistry monitoring for units 5 and 6 of another eastern European VVER. The status of the Temelin OLM systems is discussed including updates to the Temelin designs, and the other Eastern European installations and designs are also described briefly. Some of the problems encountered and lessons learned from these projects are also discussed. (R.P.)

  20. MCD 80: A modular coupling system for power line carrier transmission

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, B; Mayer, M

    1983-05-01

    Power line carrier (PLC) links are of great importance to power supply utilities. The communications equipment is linked to the H.V. system by a coupling device. Brown Boveri have developed a new modular coupling system MCD 80 which is compact, programmable and economical. The benefit of years of experience in the field went into its development. With the new system, optimum PLC couplings, R.F. through-connections and junction networks are possible for all H.V. transmission systems. A general look at the subject of PLC couplings is followed by a closer look at the main components, such as the programmable high pass coupling unit, band pass coupling unit, hybrid, separating filter, R.F. junction network and attenuator. Some typical examples are described.

  1. Characteristics of a four element gyromagnetic nonlinear transmission line array high power microwave source

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, J. M., E-mail: jared.johnson@ttu.edu; Reale, D. V.; Garcia, R. S.; Cravey, W. H.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J. [Center for Pulsed Power and Power Electronics Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409 (United States); Krile, J. T. [Department of Electromagnetics and Sensor Systems, Naval Surface Warfare Center - Dahlgren Division, Dahlgren, Virginia 22448 (United States)

    2016-05-15

    In this paper, a solid-state four element array gyromagnetic nonlinear transmission line high power microwave system is presented as well as a detailed description of its subsystems and general output capabilities. This frequency agile S-band source is easily adjusted from 2-4 GHz by way of a DC driven biasing magnetic field and is capable of generating electric fields of 7.8 kV/m at 10 m correlating to 4.2 MW of RF power with pulse repetition frequencies up to 1 kHz. Beam steering of the array at angles of ±16.7° is also demonstrated, and the associated general radiation pattern is detailed.

  2. High power, high brightness electron beam generation in a pulse-line driven pseudospark discharge

    International Nuclear Information System (INIS)

    Destler, W.W.; Segalov, Z.; Rodgers, J.; Ramaswamy, K.; Reiser, M.

    1993-01-01

    High brightness (∼10 10 A/m 2 rad 2 ), high power density (∼10 10 W/cm 2 ) electron beams have been generated by the mating of a hollow-cathode discharge device operating in the pseudospark regime to the output of a high power pulse line accelerator. Very small diameter (∼1 mm) electron beams with currents in the range 500--1000 A and energies in the range 150--300 keV have been generated with effective emittances estimated to be at or below 170 mm mrad. Such emittances are comparable to those achieved in conventional electron beam sources at current densities several orders of magnitude lower than those observed in these experiments

  3. Transmission line pulse system for avalanche characterization of high power semiconductor devices

    Science.gov (United States)

    Riccio, Michele; Ascione, Giovanni; De Falco, Giuseppe; Maresca, Luca; De Laurentis, Martina; Irace, Andrea; Breglio, Giovanni

    2013-05-01

    Because of the increasing in power density of electronic devices for medium and high power application, reliabilty of these devices is of great interest. Understanding the avalanche behaviour of a power device has become very important in these last years because it gives an indication of the maximum energy ratings which can be seen as an index of the device ruggedness. A good description of this behaviour is given by the static IV blocking characteristc. In order to avoid self heating, very relevant in high power devices, very short pulses of current have to be used, whose value can change from few milliamps up to tens of amps. The most used method to generate short pulses is the TLP (Transmission Line Pulse) test, which is based on charging the equivalent capacitance of a transmission line to high value of voltage and subsequently discharging it onto a load. This circuit let to obtain very short square pulses but it is mostly used for evaluate the ESD capability of semiconductor and, in this environment, it generates pulses of low amplitude which are not high enough to characterize the avalanche behaviour of high power devices . Advanced TLP circuit able to generate high current are usually very expensive and often suffer of distorption of the output pulse. In this article is proposed a simple, low cost circuit, based on a boosted-TLP configuration, which is capable to produce very square pulses of about one hundreds of nanosecond with amplitude up to some tens of amps. A prototype is implemented which can produce pulses up to 20A of amplitude with 200 ns of duration which can characterize power devices up to 1600V of breakdown voltage. Usage of microcontroller based logic make the circuit very flexible. Results of SPICE simulation are provided, together with experimental results. To prove the effectiveness of the circuit, the I-V blocking characteristics of two commercial devices, namely a 600V PowerMOS and a 1200V Trench-IGBT, are measured at different

  4. Demand management through centralized control system using power line communication for existing buildings

    International Nuclear Information System (INIS)

    Al-Mulla, A.; ElSherbini, A.

    2014-01-01

    Highlights: • A pilot system was developed for demand management of equipment in buildings. • The networking was based on LonWorks platform and power line communication. • Demand strategies led to load reductions up to 74% and energy savings up to 25%. • The peak load reduction is expected to reach 3.44 GW by the year 2030. - Abstract: Managing peak demand efficiently is vital for maintaining uninterrupted supply of electrical power by utility providers. In this work, a pilot system was developed for managing and controlling the demand of major power consuming equipment in buildings from a central server, while relying mostly on existing infrastructure and maintaining consumer comfort. The system was successfully demonstrated on a selected group of buildings using the LonWorks networking platform. At the building level, the system utilized power line and twisted pair communication to control the thermostats of air-conditioning (A/C) units. The higher level communication was executed through extensible markup language (XML) and simple object access protocol (SOAP). The system provided control capabilities based on A/C unit priority, thermostat temperature, building type and geographic location. The development and execution of demand management strategies for selected buildings led to peak load reductions up to 74%, in addition to energy savings up to 25%. Implementing such a system at a national level in Kuwait is estimated to reduce peak demand by 3.44 GW, amounting to capital savings of $4.13 billion. The use of existing infrastructure reduced the cost and installation time of the system. Based on the successful testing of this pilot system, a larger-scale system is being developed

  5. Field experience with advanced methods of on-line monitoring of water chemistry and corrosion degradation in nuclear power stations

    International Nuclear Information System (INIS)

    Stellwag, B.; Aaltonen, P.; Hickling, J.

    1997-01-01

    Advanced methods for on-line, in-situ water chemistry and corrosion monitoring in nuclear power stations have been developed during the past decade. The terms ''on-line'' and ''in-situ'' characterize approaches involving continuous measurement of relevant parameters in high temperature water, preferably directly in the systems and components and not in removed samples at room temperature. This paper describes the field experience to-date with such methods in terms of three examples: (1) On-line chemistry monitoring of the primary coolant during shutdown of a Type WWER-440 PWR. (2) Redox and corrosion potential measurements in final feedwater preheaters and steam generators of two large KWU PWRs over several cycles of plant operation. (3) Real-time, in-situ corrosion surveillance inside the calundia vault of a CANDU reactor. The way in which water chemistry sensors and corrosion monitoring sensors complement each other is outlined: on-line, in-situ measurement of pH, conductivity and redox potential gives information about the possible corrosivity of the environment. Electrochemical noise techniques display signals of corrosion activity under the actual environmental conditions. A common experience gained from separate use of these different types of sensors has been that new and additional information about plants and their actual process conditions is obtained. Moreover, they reveal the intimate relationship between the operational situation and its consequences for the quality of the working fluid and the corrosion behaviour of the plant materials. On this basis, the efficiency of the existing chemistry sampling and control system can be checked and corrosion degradation can be minimized. Furthermore, activity buildup in the primary circuit can be studied. Further significant advantages can be expected from an integration of these various types of sensors into a common water chemistry and corrosion surveillance system. For confirmation, a complete set of sensors

  6. Field experience with advanced methods of on-line monitoring of water chemistry and corrosion degradation in nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Stellwag, B [Siemens AG Unternehmensbereich KWU, Erlangen (Germany); Aaltonen, P [Technical Research Centre of Finland, Espoo (Finland); Hickling, J [CML GmbH, Erlangen (Germany)

    1997-02-01

    Advanced methods for on-line, in-situ water chemistry and corrosion monitoring in nuclear power stations have been developed during the past decade. The terms ``on-line`` and ``in-situ`` characterize approaches involving continuous measurement of relevant parameters in high temperature water, preferably directly in the systems and components and not in removed samples at room temperature. This paper describes the field experience to-date with such methods in terms of three examples: (1) On-line chemistry monitoring of the primary coolant during shutdown of a Type WWER-440 PWR. (2) Redox and corrosion potential measurements in final feedwater preheaters and steam generators of two large KWU PWRs over several cycles of plant operation. (3) Real-time, in-situ corrosion surveillance inside the calundia vault of a CANDU reactor. The way in which water chemistry sensors and corrosion monitoring sensors complement each other is outlined: on-line, in-situ measurement of pH, conductivity and redox potential gives information about the possible corrosivity of the environment. Electrochemical noise techniques display signals of corrosion activity under the actual environmental conditions. A common experience gained from separate use of these different types of sensors has been that new and additional information about plants and their actual process conditions is obtained. Moreover, they reveal the intimate relationship between the operational situation and its consequences for the quality of the working fluid and the corrosion behaviour of the plant materials. On this basis, the efficiency of the existing chemistry sampling and control system can be checked and corrosion degradation can be minimized. Furthermore, activity buildup in the primary circuit can be studied. Further significant advantages can be expected from an integration of these various types of sensors into a common water chemistry and corrosion surveillance system. (Abstract Truncated)

  7. Usefulness of DC power flow for active power flow analysis with flow controlling devices

    NARCIS (Netherlands)

    Van Hertem, D.; Verboomen, J.; Purchala, K.; Belmans, R.; Kling, W.L.

    2006-01-01

    DC power flow is a commonly used tool for contingency analysis. Recently, due to its simplicity and robustness, it also becomes increasingly used for the real-time dispatch and techno-economic analysis of power systems. It is a simplification of a full power flow looking only at active power.

  8. Radioisotope Characterization of HB Line Low Activity Waste

    International Nuclear Information System (INIS)

    Snyder, S.J.

    1999-01-01

    The purpose of this document is to provide a physical, chemical, hazardous and radiological characterization of Low-Level Waste (LLW) generated in HB-Line as required by the 1S Manual, Savannah River Site Waste Acceptance Criteria Manual

  9. Commissioning of the 28 GHz ECRH power transmission line for the TJ-II stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Martínez-Fernández, J., E-mail: jose.martinez@ciemat.es [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Cappa, Á. [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Chirkov, A. [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod (Russian Federation); Ros, A.; Tolkachev, A.; Catalán, G.; Soleto, A.; Redondo, M. [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Doane, J.L.; Anderson, J.P. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States)

    2015-10-15

    Highlights: • The 28 GHz power transmission line of the TJ-II stellarator is described. • Mismatch and alignment problems are covered, presenting infrared measurements. • Beam distortion in the matching optics unit led to unwanted modes in the waveguide. • After a redesign distortion was eliminated and coupling maximized. • Final measurements suggest finer alignment must be performed. - Abstract: The commissioning of the 28 GHz power transmission line of the TJ-II stellarator, designed for the excitation of electron Bernstein waves (EBW) through the O-X-B mode conversion process, is presented in this paper. Based upon a comprehensive set of thermal measurements, its purpose is to go into details about the several problems that arouse during the whole process, namely higher order modes excitation because of the wider beam size and alignment mismatches at the waveguide mouth. All these drawbacks may have prevented the correct O-X mode conversion, thus providing a reasonable explanation for the unsuccessful EBW heating experiments.

  10. Power line conductor icing prevention by the Joule effect : parametric analysis and energy requirements

    Energy Technology Data Exchange (ETDEWEB)

    Peter, Z.; Farzaneh, M.; Kiss, L.I. [Quebec Univ., Chicoutimi, PQ (Canada). Industrial Chair on Atmospheric Icing of Power Network Equipment

    2005-07-01

    A mathematical model to calculate the minimum current intensity needed to prevent potentially damaging ice accretion on power line conductors was presented. The influence of atmospheric parameters such as wind speed, air temperature and liquid water were considered. Energy analysis was developed for an aluminum and steel reinforced conductor with circular cylindrical wire and concentric layers. Atmospheric parameters and the duration of the freezing conditions were considered with reference to the Joule effect. The model was then compared with experiments and simulations performed at an icing wind tunnel and in a climate room. It was determined that the equivalent thermal conductivity of the conductor should be assessed to identify the temperature distribution in the power line conductor. The radial component of the thermal conductivity was estimated on the basis of experiments performed in the wind tunnel, which provided a good estimation of the equivalent thermal conductivity and overall heat transfer coefficient around the stranded conductor. Experimental results were compared with values obtained from theoretically equivalent conductivity models. It was observed that the convective heat transfer coefficients around stranded conductors were higher than around smooth cylinders, and that the mathematical calculations slightly overestimated the wind tunnel measurements due to difficulties in estimating the wetted surface and the overall convection heat transfer coefficient around a stranded conductor. The typical range for the equivalent thermal conductivity of stranded conductors was also presented. 13 refs., 1 tab., 11 figs.

  11. What's in the Wind? Determining the Properties of Outflowing Gas in Powerful Broad Absorption Line Quasars

    Science.gov (United States)

    Leighly, Karen

    2017-08-01

    A significant fraction of quasars exhibits blueshifted broadabsorption lines (BALs) in their rest-UV spectra, indicating powerfuloutflows emerging from the central engine. These outflows may removeangular momentum to enable black hole growth, enrich the intergalacticmedium with metals, and trigger quenching of star formation ingalaxies. Despite years of study, the physical conditions of theoutflowing gas are poorly understood. The handful of objects that havebeen subjected to detailed analysis are atypical and characterized byrelatively narrow lines where blending is unimportant. However,investigating more powerful BAL quasars will give us better insightinto the types of outflows much more likely to impact galaxyevolution.SimBAL is a novel spectral synthesis fitting method for BAL quasarsthat uses Bayesian model calibration to compare synthetic to observedspectra. With the model inputs of ionization parameter, columndensity, and covering fraction specified, the gas properties givingrise to the BAL features can be determined. We propose to applySimBAL to archival spectra of a sample of 14 luminous BAL quasars to characterize their bulk outflow properties as a function of velocityfor the first time. Our results will show the range of parameterstypical of powerful outflows, an essential step towards constrainingthe physics behind quasar winds and thus their impact on theirenvironments.

  12. Wideband Impulse Modulation and Receiver Algorithms for Multiuser Power Line Communications

    Directory of Open Access Journals (Sweden)

    Andrea M. Tonello

    2007-01-01

    Full Text Available We consider a bit-interleaved coded wideband impulse-modulated system for power line communications. Impulse modulation is combined with direct-sequence code-division multiple access (DS-CDMA to obtain a form of orthogonal modulation and to multiplex the users. We focus on the receiver signal processing algorithms and derive a maximum likelihood frequency-domain detector that takes into account the presence of impulse noise as well as the intercode interference (ICI and the multiple-access interference (MAI that are generated by the frequency-selective power line channel. To reduce complexity, we propose several simplified frequency-domain receiver algorithms with different complexity and performance. We address the problem of the practical estimation of the channel frequency response as well as the estimation of the correlation of the ICI-MAI-plus-noise that is needed in the detection metric. To improve the estimators performance, a simple hard feedback from the channel decoder is also used. Simulation results show that the scheme provides robust performance as a result of spreading the symbol energy both in frequency (through the wideband pulse and in time (through the spreading code and the bit-interleaved convolutional code.

  13. Resource Allocation with Adaptive Spread Spectrum OFDM Using 2D Spreading for Power Line Communications

    Directory of Open Access Journals (Sweden)

    Baudais Jean-Yves

    2007-01-01

    Full Text Available Bit-loading techniques based on orthogonal frequency division mutiplexing (OFDM are frequently used over wireline channels. In the power line context, channel state information can reasonably be obtained at both transmitter and receiver sides, and adaptive loading can advantageously be carried out. In this paper, we propose to apply loading principles to an spread spectrum OFDM (SS-OFDM waveform which is a multicarrier system using 2D spreading in the time and frequency domains. The presented algorithm handles the subcarriers, spreading codes, bits and energies assignment in order to maximize the data rate and the range of the communication system. The optimization is realized at a target symbol error rate and under spectral mask constraint as usually imposed. The analytical study shows that the merging principle realized by the spreading code improves the rate and the range of the discrete multitone (DMT system in single and multiuser contexts. Simulations have been run over measured power line communication (PLC channel responses and highlight that the proposed system is all the more interesting than the received signal-to-noise ratio (SNR is low.

  14. Resource Allocation with Adaptive Spread Spectrum OFDM Using 2D Spreading for Power Line Communications

    Science.gov (United States)

    Baudais, Jean-Yves; Crussière, Matthieu

    2007-12-01

    Bit-loading techniques based on orthogonal frequency division mutiplexing (OFDM) are frequently used over wireline channels. In the power line context, channel state information can reasonably be obtained at both transmitter and receiver sides, and adaptive loading can advantageously be carried out. In this paper, we propose to apply loading principles to an spread spectrum OFDM (SS-OFDM) waveform which is a multicarrier system using 2D spreading in the time and frequency domains. The presented algorithm handles the subcarriers, spreading codes, bits and energies assignment in order to maximize the data rate and the range of the communication system. The optimization is realized at a target symbol error rate and under spectral mask constraint as usually imposed. The analytical study shows that the merging principle realized by the spreading code improves the rate and the range of the discrete multitone (DMT) system in single and multiuser contexts. Simulations have been run over measured power line communication (PLC) channel responses and highlight that the proposed system is all the more interesting than the received signal-to-noise ratio (SNR) is low.

  15. Conducted Interference Immunity Characteristics to High-speed Power Line Communication System

    Science.gov (United States)

    Tokuda, Masamitsu; Hosoya, Satoshi; Yamagata, Toru; Matsuo, Takashi

    In this paper, we measured the immunity characteristics to the conducted interference wave, from the aspect of PHY rate (physical layer data rate) of PLC (Power Line Communication) system, and compared with simulation results by MATLAB/ Simulink. When the interference signal is impressed to the OFDM (Orthogonal Frequency Division Multiplexing) signal, the PHY rate decrease rapidly below C/I (Carrier / Interference) = 25dB and become nearly zero around C/I = -35dB, and so it turns out that the PLC System with OFDM signal has a good narrowband interference immunity characteristic. In addition, it is revealed that the PHY rate of PLC modem can be calculated by MATLAB/Simulink even when the narrowband interference signal is impressed through the power line. Furthermore, we examined the improving effect of the notch band for the immunity characteristics to the conducted interference wave. As a result, it is revealed that the PHY rate normalized by the maximum value increases by 15∼25% by inserting the notch when impressing the interference signal in the notch band and C/I is improved by 10∼15dB by inserting the notch.

  16. Analysis and Design of Timing Recovery Schemes for DMT Systems over Indoor Power-Line Channels

    Directory of Open Access Journals (Sweden)

    Cortés José Antonio

    2007-01-01

    Full Text Available Discrete multitone (DMT modulation is a suitable technique to cope with main impairments of broadband indoor power-line channels: spectral selectivity and cyclic time variations. Due to the high-density constellations employed to achieve the required bit-rates, synchronization issues became an important concern in these scenarios. This paper analyzes the performance of a conventional DMT timing recovery scheme designed for linear time-invariant (LTI channels when employed over indoor power lines. The influence of the channel cyclic short-term variations and the sampling jitter on the system performance is assessed. Bit-rate degradation due to timing errors is evaluated in a set of measured channels. It is shown that this synchronization mechanism limits the system performance in many residential channels. Two improvements are proposed to avoid this end: a new phase error estimator that takes into account the short-term changes in the channel response, and the introduction of notch filters in the timing recovery loop. Simulations confirm that the new scheme eliminates the bit-rate loss in most situations.

  17. Magnetic fields and cancer in people residing near Swedish high voltage power lines

    Energy Technology Data Exchange (ETDEWEB)

    Feychting, M; Ahlbom, A

    1992-01-01

    The study was designed as a case-control study, based on the population comprised of everyone who have lived on a property located within 300 meters from any of the 220 and 400 kV power lines in Sweden during the period from 1960 through 1985. For adults it was required that the duration of residence was at least one year. The corridor was chosen to be wide enough to ensure that it included both exposed and unexposed homes. The cases were all instances of cancer diagnosed between 1960-85. For children, all types of cancer were included, while for adults the study was restricted to leukemia and brain tumors. The controls were matched to the cases on time of diagnosis, age, sex, parish, and power line. Exposure was assessed in several different ways. First, spot measurements were performed in the homes of the subjects. Second, the magnetic fields generated by the power lines were calculated by means of a computer program taking distance, line configuration, and load into account. For childhood leukemia and with cut off points at 0.1 and 0.2 [mu]T, the relative risk (RR) increased over the two exposure levels and was estimated at 2.7 (95% c.l.: 1.0-6,3) for 0.2 [mu]T and over. The test for trend gave a p-value of 0.02. When the upper cut off point was shifted to 0.3 [mu]T the RR was instead 3.8 (1.4-9.3) and the corresponding trend test gave a p-value of 0.005. In adults and for magnetic fields of 0.2 [mu]T and over, the RR for acute myeloid (AML) and chronic myeloid leukemia (CML) were estimated at 1.7 (0.8-3.5) and 1.7 (0.7-3.8), respectively. This result persisted in most analyses. For brain tumours no association was seen. The results provide support for the hypothesis that exposure to magnetic fields increase the risk of cancer. This is most evident in childhood leukemia. What aspect of the fields that might be involved remains unclear. (6 figs., 82 tabs., 16 refs.).

  18. Magnetic fields and cancer in people residing near Swedish high voltage power lines

    Energy Technology Data Exchange (ETDEWEB)

    Feychting, M; Ahlbom, A

    1993-12-31

    The study was designed as a case-control study, based on the population comprised of everyone who have lived on a property located within 300 meters from any of the 220 and 400 kV power lines in Sweden during the period from 1960 through 1985. For adults it was required that the duration of residence was at least one year. The corridor was chosen to be wide enough to ensure that it included both exposed and unexposed homes. The cases were all instances of cancer diagnosed between 1960-85. For children, all types of cancer were included, while for adults the study was restricted to leukemia and brain tumors. The controls were matched to the cases on time of diagnosis, age, sex, parish, and power line. Exposure was assessed in several different ways. First, spot measurements were performed in the homes of the subjects. Second, the magnetic fields generated by the power lines were calculated by means of a computer program taking distance, line configuration, and load into account. For childhood leukemia and with cut off points at 0.1 and 0.2 {mu}T, the relative risk (RR) increased over the two exposure levels and was estimated at 2.7 (95% c.l.: 1.0-6,3) for 0.2 {mu}T and over. The test for trend gave a p-value of 0.02. When the upper cut off point was shifted to 0.3 {mu}T the RR was instead 3.8 (1.4-9.3) and the corresponding trend test gave a p-value of 0.005. In adults and for magnetic fields of 0.2 {mu}T and over, the RR for acute myeloid (AML) and chronic myeloid leukemia (CML) were estimated at 1.7 (0.8-3.5) and 1.7 (0.7-3.8), respectively. This result persisted in most analyses. For brain tumours no association was seen. The results provide support for the hypothesis that exposure to magnetic fields increase the risk of cancer. This is most evident in childhood leukemia. What aspect of the fields that might be involved remains unclear. (6 figs., 82 tabs., 16 refs.).

  19. Seasonal and Local Characteristics of Lightning Outages of Power Distribution Lines in Hokuriku Area

    Science.gov (United States)

    Sugimoto, Hitoshi; Shimasaki, Katsuhiko

    The proportion of the lightning outages in all outages on Japanese 6.6kV distribution lines is high with approximately 20 percent, and then lightning protections are very important for supply reliability of 6.6kV lines. It is effective for the lightning performance to apply countermeasures in order of the area where a large number of the lightning outages occur. Winter lightning occurs in Hokuriku area, therefore it is also important to understand the seasonal characteristics of the lightning outages. In summer 70 percent of the lightning outages on distribution lines in Hokuriku area were due to sparkover, such as power wire breakings and failures of pole-mounted transformers. However, in winter almost half of lightning-damaged equipments were surge arrester failures. The number of the lightning outages per lightning strokes detected by the lightning location system (LLS) in winter was 4.4 times larger than that in summer. The authors have presumed the occurrence of lightning outages from lightning stroke density, 50% value of lightning current and installation rate of lightning protection equipments and overhead ground wire by multiple regression analysis. The presumed results suggest the local difference in the lightning outages.

  20. On-line calibration of process instrumentation channels in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hashemian, H.M.; Farmer, J.P. [Analysis and Measurement Services Corp., Knoxville, TN (United States)

    1995-04-01

    An on-line instrumentation monitoring system was developed and validated for use in nuclear power plants. This system continuously monitors the calibration status of instrument channels and determines whether or not they require manual calibrations. This is accomplished by comparing the output of each instrument channel to an estimate of the process it is monitoring. If the deviation of the instrument channel from the process estimate is greater than an allowable limit, then the instrument is said to be {open_quotes}out of calibration{close_quotes} and manual adjustments are made to correct the calibration. The success of the on-line monitoring system depends on the accuracy of the process estimation. The system described in this paper incorporates both simple intercomparison techniques as well as analytical approaches in the form of data-driven empirical modeling to estimate the process. On-line testing of the calibration of process instrumentation channels will reduce the number of manual calibrations currently performed, thereby reducing both costs to utilities and radiation exposure to plant personnel.

  1. Losses at magnetic nulls in pulsed-power transmission line systems

    International Nuclear Information System (INIS)

    Mendel, C.W. Jr.; Pointon, T.D.; Savage, M.E.; Seidel, D.B.; Magne, I.; Vezinet, R.

    2006-01-01

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds

  2. Reactive power compensation. System service - line quality. 2. ed.; Blindleistungskompensation. Systemdienstleistung - Netzqualitaet

    Energy Technology Data Exchange (ETDEWEB)

    Grosse-Gehling, Martin; Just, Wolfgang; Reese, Juergen; Schlabbach, Juergen

    2013-11-01

    Reactive power compensation is playing an increasingly important role as the need for an efficient use of operating equipment and power grids continues to grow. This book presents the fundamentals of reactive power compensation in low and medium voltage grids, offering a wealth of application and calculation examples that will further the reader's understanding of the following topics: 1. design, dimensioning and operation of capacitors and capacitor installations; 2. long-term stability and ageing of capacitor installations; 3. use of passive and active filters; 4. improvement of voltage quality by means of filters and capacitor installations; 5. provision of reactive power compensation by means of power electronics; 6. costs and economic efficiency of reactive power compensation and filter equipment; 7. considerations from the viewpoint of the power supply industry; price regulations; 8. information requirements concerning PCB-containing capacitors; 9. climate protection and energy efficiency through reactive power compensation; 10. technical connection requirements and guidelines; 11. special technical issues concerning the use of reactive power compensation installations. [German] Die Blindleistungskompensation gewinnt angesichts der Notwendigkeit zur erhoehten Ausnutzung der Betriebsmittel und Netze zunehmend an Bedeutung. In diesem Buch werden die Grundlagen der Blindleistungskompensation in Nieder- und Mittelspannungsnetzen beschrieben und folgende Themen anhand zahlreicher Anwendungs- und Berechnungsbeispiele vertieft: 1. Aufbau, Auslegung und Betrieb von Kondensatoren und Kondensatoranlagen, 2. Langzeitstabilitaet und Alterung von Kondensatoranlagen, 3. Einsatz passiver und aktiver Filter, 4. Verbesserung der Spannungsqualitaet durch Filter und Kondensatoranlagen, 5. Blindleistungsbereitstellung mit Leistungselektronik, 6. Kosten und Wirtschaftlichkeit von Kompensations- und Filteranlagen, 7. Elektrizitaetswirtschaftliche Betrachtungen

  3. Agent-based power sharing scheme for active hybrid power sources

    Science.gov (United States)

    Jiang, Zhenhua

    The active hybridization technique provides an effective approach to combining the best properties of a heterogeneous set of power sources to achieve higher energy density, power density and fuel efficiency. Active hybrid power sources can be used to power hybrid electric vehicles with selected combinations of internal combustion engines, fuel cells, batteries, and/or supercapacitors. They can be deployed in all-electric ships to build a distributed electric power system. They can also be used in a bulk power system to construct an autonomous distributed energy system. An important aspect in designing an active hybrid power source is to find a suitable control strategy that can manage the active power sharing and take advantage of the inherent scalability and robustness benefits of the hybrid system. This paper presents an agent-based power sharing scheme for active hybrid power sources. To demonstrate the effectiveness of the proposed agent-based power sharing scheme, simulation studies are performed for a hybrid power source that can be used in a solar car as the main propulsion power module. Simulation results clearly indicate that the agent-based control framework is effective to coordinate the various energy sources and manage the power/voltage profiles.

  4. A fast, robust algorithm for power line interference cancellation in neural recording

    Science.gov (United States)

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-04-01

    Objective. Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. Approach. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. Main results. The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. Significance. The proposed algorithm features a highly robust operation, fast adaptation to

  5. Stabilization and control of tie-line power flow of microgrid including wind generation by distributed energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Molina, M.G.; Mercado, P.E. [CONICET, Instituto de Energia Electrica, Universidad Nacional de San Juan, Av. Libertador San Martin Oeste 1109, J5400ARL San Juan (Argentina)

    2010-06-15

    High penetration of wind generation in electrical microgrids causes fluctuations of tie-line power flow and significantly affects the power system operation. This can lead to severe problems, such as system frequency oscillations, and/or violations of power lines capability. With proper control, a distribution static synchronous compensator (DSTATCOM) integrated with superconducting magnetic energy storage (SMES) is able to significantly enhance the dynamic security of the power system. This paper proposes the use of a SMES system in combination with a DSTATCOM as effective distributed energy storage (DES) for stabilization and control of the tie-line power flow of microgrids incorporating wind generation. A new detailed model of the integrated DSTATCOM-SMES device is derived and a novel three-level control scheme is designed. The dynamic performance of the proposed control schemes is fully validated using MATLAB/Simulink. (author)

  6. Impact evaluation of conducted UWB transients on loads in power-line networks

    Directory of Open Access Journals (Sweden)

    B. Li

    2017-09-01

    Full Text Available Nowadays, faced with the ever-increasing dependence on diverse electronic devices and systems, the proliferation of potential electromagnetic interference (EMI becomes a critical threat for reliable operation. A typical issue is the electronics working reliably in power-line networks when exposed to electromagnetic environment. In this paper, we consider a conducted ultra-wideband (UWB disturbance, as an example of intentional electromagnetic interference (IEMI source, and perform the impact evaluation at the loads in a network. With the aid of fast Fourier transform (FFT, the UWB transient is characterized in the frequency domain. Based on a modified Baum–Liu–Tesche (BLT method, the EMI received at the loads, with complex impedance, is computed. Through inverse FFT (IFFT, we obtain time-domain responses of the loads. To evaluate the impact on loads, we employ five common, but important quantifiers, i.e., time-domain peak, total signal energy, peak signal power, peak time rate of change and peak time integral of the pulse. Moreover, to perform a comprehensive analysis, we also investigate the effects of the attributes (capacitive, resistive, or inductive of other loads connected to the network, the rise time and pulse width of the UWB transient, and the lengths of power lines. It is seen that, for the loads distributed in a network, the impact evaluation of IEMI should be based on the characteristics of the IEMI source, and the network features, such as load impedances, layout, and characteristics of cables.

  7. Review of fire behavior during passage of Sandy Lake Fire 13 (NWT) across a Northwest Territories Power Corporation transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, D.; Thomasson, J.

    2009-03-15

    The Sandy Lake Fire 13 of July 2008 was an intense forest fire that burned up to and across a power line right-of-way in the Northwest Territories, approximately 160 km northwest of Fort Smith. The terrain in the area is flat and vegetation is characterized by boreal pine and black spruce uplands with black spruce and tamarack in lower areas and adjacent to wetlands. This report documented post fire conditions at locations where the fire crossed the power line. The towers on this line were made from an aluminum alloy and may not have had the same resistance to heat damage as steel towers, more commonly used on major transmission lines. The transmission line was de-energized during the fire. Therefore, the effects of fire on power transmission were not documented. Although the intense wildfire crossed sections of the power line, it did not result in observable damage to the towers or lines. Fire intensity was likely greater than 40,000 kw/m along some sections of the right-of-way. Although the management of the right-of-way may have reduced heat exposure to the transmission towers, it did not stop the fire. Pine mixed with an aspen component greater than 50 per cent had a mitigating effect on fire behaviour. The fire did not result in any immediate damage to the power line infrastructure. It was concluded that the use of power lines for fire operations should consider right-of-way width in order to assess equipment maneuverability, especially around tower guy wires. 5 refs., 1 tab., 12 figs.

  8. Active Power Regulation based on Droop for AC Microgrid

    DEFF Research Database (Denmark)

    Li, Chendan; Coelho, Ernane A. A.; Firoozabadi, Mehdi Savaghebi

    2015-01-01

    In this paper, two different control strategies are proposed to address the active power regulation issue in AC microgrids. The principle of power regulation in the droop controller is firstly introduced. Frequency scheduling and droop gain scheduling on top of droop control is proposed...... to successfully follow the active power command. The limitation of each method is discussed in term of small signal stability and light load sharing, respectively. Discussion on the effects of power command is also given. The simulation is carried out for both the strategies to verify the active power control...

  9. Social power and approach-related neural activity

    OpenAIRE

    Boksem, Maarten; Smolders, Ruud; Cremer, David

    2009-01-01

    textabstractIt has been argued that power activates a general tendency to approach whereas powerlessness activates a tendency to inhibit. The assumption is that elevated power involves reward-rich environments, freedom and, as a consequence, triggers an approach-related motivational orientation and attention to rewards. In contrast, reduced power is associated with increased threat, punishment and social constraint and thereby activates inhibition-related motivation. Moreover, approach motiva...

  10. Liver system. V. Activation-extinction line of cyclic hepatocyte activities.

    Science.gov (United States)

    Dioguardi, N; Brambilla, F; Dell'Oca, M; Arosio, E; Parmeggiani, L

    1991-01-01

    The excitation-extintion line of hepatocytes from an inert state towards the stabilization of a given activity is described. Within the cell, the switching on of any given activity is a competitive process among different activities. The process is driven by the influence field created in the environment of the Rappaport acinus by sinusoidal blood which changes its characteristics during its passage from the portal zone to the central vein. Every step of the excitation-extintion pathway follows the so-called law of autoisodiasostasis (AIS), i.e. it is characterized by an oscillatory motion between restoring (homopoiesis or HP) and working (homeorhesis or HR) states. Since the cyclical bistable equilibrium of AIS characterizes all conditions of hepatocyte activities, the AIS cycle can be defined a limit cycle.

  11. The Flooding Water Source Analysis following the Feed Line Break at the Compartment outside Containment for Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Song, Dong Soo [Korea Electric Power Research Institute, Daejeon (Korea, Republic of); Park, Young Chan [ACT, Daejeon (Korea, Republic of)

    2007-07-01

    The Periodic Safety Review(PSR) has been performing for the operating nuclear power plant in Korea. One of the PSR evaluation items is environmental qualification. Flooding issue for nuclear power plants designed and built in 1970 is extremely severe for main steam header compartment and main feed water line region of intermediate building and lower floor. This study presents to analyze flood level of feed water line breaks for the Westinghouse nuclear power plant. This analyses provides the mass and energy releases using the developed methodology for a break outside containment. For the analyses RETRAN-3D computer program is used.

  12. Feasibility study on the interconnection of traction and other power line infrastructures; Machbarkeitsstudie zur Verknuepfung von Bahn- und Energieleitungsinfrastrukturen

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Lutz [Hannover Univ. (Germany). Inst. fuer Energieversorgung und Hochspannungstechnik; Stephan, Arnd [Technische Univ. Dresden (Germany). Professur Elektrische Bahnen; Weyer, Hartmut [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany). Inst. fuer Deutsches und Internationales Berg- und Energierecht

    2013-06-15

    It was the purpose of the feasibility study to find out if and to what extent the existing transmission route potentials of the 16.7 Hz traction power network (DB Energie GmbH) can be used for the installation of new transmission lines of the standard 50 Hz power supply system. Of importance is here the question if and in which way the integration of new three-phase or DC overhead lines or cable systems in existing traction power routes is technically feasible, and to what extent such interconnection offers a potential for the acceleration of the planning and approval processes. (orig.)

  13. Site selection of active damper for stabilizing power electronics based power distribution system

    DEFF Research Database (Denmark)

    Yoon, Changwoo; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    electronics based power device, which provides an adjustable damping capability to the power system where the voltage harmonic instability is measured. It can stabilize by adjusting the equivalent node impedance with its plug and play feature. This feature gives many degrees of freedom of its installation......Stability in the nowadays distribution power system is endangered by interaction problems that may arise from newly added power-electronics based power devices. Recently, a new concept to deal with this higher frequency instability, the active damper, has been proposed. The active damper is a power...... point when the system has many nodes. Therefore, this paper addresses the proper placement of an active damper in an unstable small-scale power distribution system. A time-domain model of the Cigre benchmark low-vltage network is used as a test field. The result shows the active damper location...

  14. Flight route Designing and mission planning Of power line inspecting system Based On multi-sensor UAV

    International Nuclear Information System (INIS)

    Xiaowei, Xie; Zhengjun, Liu; Zhiquan, Zuo

    2014-01-01

    In order to obtain various information of power facilities such as spatial location, geometry, images data and video information in the infrared and ultraviolet band and so on, Unmanned Aerial Vehicle (UAV) power line inspecting system needs to integrate a variety of sensors for data collection. Low altitude and side-looking imaging are required for UAV flight to ensure sensors to acquire high-quality data and device security. In this paper, UAV power line inspecting system is deferent from existing ones that used in Surveying and Mapping. According to characteristics of UAV for example equipped multiple sensor, side-looking imaging, working at low altitude, complex terrain conditions and corridor type flight, this paper puts forward a UAV power line inspecting scheme which comprehensively considered of the UAV performance, sensor parameters and task requirements. The scheme is finally tested in a region of Guangdong province, and the preliminary results show that the scheme is feasible

  15. Digital lock-in techniques for adaptive power-line interference extraction.

    Science.gov (United States)

    Dobrev, Dobromir; Neycheva, Tatyana; Mudrov, Nikolay

    2008-07-01

    This paper presents a simple digital approach for adaptive power-line (PL) or other periodic interference extraction. By means of two digital square (or sine) wave mixers, the real and imaginary parts of the interference are found, and the interference waveform is synthesized and finally subtracted. The described technique can be implemented in an open-loop architecture where the interference is synthesized as a complex sinusoid or in a closed-loop architecture for automatic phase and gain control. The same approach can be used for removal of the fundamental frequency of the PL interference as well as its higher harmonics. It is suitable for real-time operation with popular low-cost microcontrollers.

  16. Demonstration of an automated on-line surveillance system at a commercial nuclear power plant

    International Nuclear Information System (INIS)

    Smith, C.M.; Sweeney, F.J.

    1983-01-01

    As a first step in demonstrating the practicality of performing continuous on-line surveillance of the performance of nuclear steam supply systems using noise related techniques, Oak Ridge National Laboratory is operating a computerized noise signal data acquisition and processing system at the Sequoyah Unit 1 Nuclear Plant, an 1148 MWe four-loop Westinghouse pressurized water reactor (PWR) located near Chattanooga, Tennessee. The principal objective is to establish, with a degree of continuity and completeness not previously achieved, the long-term characteristics of signals from neutron detectors and process sensors in order to evaluate the feasibility of detecting and diagnosing anomalous reactor conditions by means of changes in these signals. The system is designed to automatically screen the gathered data, using a number of descriptors derived from the power spectra of the monitored signals, and thereby select for the noise analyst's perusal only those data which differ statistically from norms which the system has previously established

  17. Construction of a 500 kV aerial power line in East Java

    Energy Technology Data Exchange (ETDEWEB)

    Kaeufl, O; Paschen, R; Kummermehr, R

    1987-10-12

    The authors report on the technical preparations and the construction of a 500 kv, four-bundle power line with a pylon tonnage of approximately 10,000 t of steel and a route length of 251 km in Indonesia. Due to the difficult terrain conditions, the sensitive infrastructure and the extremely short construction period, this project was a special technological challenge. Initially, the authors explain the technical planning of Brown Boveri with emphasis on foundations and assembly. As part of this tailor-made concept new technological solutions were used. They were instrumental in the successful completion of the project in only 19 months by the end of 1986 to the complete satisfaction of the customer. The authors also comment on the pracitcal experiences gained during the construction.

  18. Analysis of Power Enhancement for a Row of Wind Turbines Using the Actuator Line Technique

    International Nuclear Information System (INIS)

    Mikkelsen, Robert; Soerensen, Jens N; Oeye, Stig; Troldborg, Niels

    2007-01-01

    The effect of wake interaction for a row of three wind turbines in a wind farm is analysed using the actuator line technique. Both full wake and half wake situations are considered with the aim of deriving the optimal pitch setting of the foremost turbine, with respect to the total power from the row. The mutual distance between the turbines is 5 diameters and the turbines are considered to operate in a wind shear with an exponent of 0.15, with the rotor centre located at 1.4 radii from the ground. The main findings reveal clear effects of reducing the loading on the foremost turbine towards increased production of turbine 2 and 3 in a row

  19. Calculation and reduction of the sound emissions of overhead power lines

    International Nuclear Information System (INIS)

    Straumann, U.

    2007-01-01

    In this dissertation, Ulrich Straumann of the Swiss Federal Institute of Technology in Zurich, Switzerland, discusses the reduction of sound emissions from overhead power lines. Corona-discharges occur during wet weather or when foggy or icing conditions prevail. Apart from these wide-band crackling noises, low-frequency, tonal emissions also occur. The CONOR (Corona Noise Reduction) project examined these emissions at a frequency of twice the mains frequency and looked for economically feasible solutions to the problems caused by them. The source of these emissions and the mechanisms causing them are discussed. Also, ways of calculating their strength are presented. The effects of varying cable geometry and construction are discussed, as are hydrophilic coatings that could be used to reduce sound emissions.

  20. Extremum seeking x-ray position feedback using power line harmonic leakage as the perturbation

    Directory of Open Access Journals (Sweden)

    S. Zohar

    2016-09-01

    Full Text Available Small x-ray beam sizes necessary for probing nanoscale phenomena require exquisite stability to prevent data corruption by noise. One source of instability at synchrotron radiation x-ray beamlines is the slow detuning of x-ray optics to marginal alignment where the onset of clipping increases the beam’s susceptibility to higher frequency position oscillations. In this article, we show that a 1  μm amplitude horizontal x-ray beam oscillation driven by power line harmonic leakage into the electron storage ring can be used as perturbation for horizontal position extremum seeking feedback. Feedback performance is characterized by convergence to 1.5% away from maximum intensity at optimal alignment.

  1. Power plant experience with artificial intelligence based, on-line diagnostic systems

    International Nuclear Information System (INIS)

    Osborne, R.L.; Coffman, M.

    1987-01-01

    The utility industry is entering a period when generation equipment availability becomes increasingly critical due to the lack of new power plants being planned and built. The increasing percentage of all electric homes adding to peak demands requires more plant equipment to be used in a cyclic duty mode. Availability is on the increase with forced and planned maintenance hours decreasing. Factors that are contributing to this improvement are new units coming on-line with the latest in technology coupled with the installation of retrofit components containing that same technology such as the Rigi-Flex generators and ruggedized turbine rotors. In conjunction with hardware advances, technology advancements in monitoring and diagnostics are permitting the identification of potential malfunctions so that corrective actions can be taken, thus preventing lengthy outages. It is this last area that this paper will address

  2. Robust suppression of nonstationary power-line interference in electrocardiogram signals

    International Nuclear Information System (INIS)

    Li, Guojun; Zeng, Xiaopin; Zhou, Yu; Liu, Guojin; Zhou, Xichuan; Zhou, Xiaona

    2012-01-01

    It is a challenge to suppress time-varying power-line interference (PLI) with various levels in electrocardiogram (ECG) signals. Most previous attempts of tracking and suppressing the nonstationary PLI signal are based on the least-squares (LS) algorithm. This makes these methods susceptible to QRS complex in suppressing a low-level PLI signal which is frequently coupled in battery-operated ECG equipment. To address the limitation of LS-based methods, this study presents a robust PLI suppression system based on a robust extension of the Kalman filter. In addition, we used an improved version of empirical mode decomposition to further attenuate the QRS complex. Experiments show that our system could effectively suppress the PLI while preserving meaningful ECG components at various interference levels. (paper)

  3. Software Sub-system in Loading Automatic Test System for the Measurement of Power Line Filters

    Directory of Open Access Journals (Sweden)

    Yu Bo

    2017-01-01

    Full Text Available The loading automatic test system for measurement of power line filters are in urgent demand. So the software sub-system of the whole test system was proposed. Methods: structured the test system based on the virtual instrument framework, which consisted of lower and up computer and adopted the top down approach of design to perform the system and its modules, according to the measurement principle of the test system. Results: The software sub-system including human machine interface, data analysis and process software, expert system, communication software, control software in lower computer, etc. had been designed. Furthermore, it had been integrated into the entire test system. Conclusion: This sub-system provided a fiendly software platform for the whole test system, and had many advantages such as strong functions, high performances, low prices. It not only raises the test efficiency of EMI filters, but also renders some creativities.

  4. Model based active power control of a wind turbine

    DEFF Research Database (Denmark)

    Mirzaei, Mahmood; Soltani, Mohsen; Poulsen, Niels Kjølstad

    2014-01-01

    in the electricity market that selling the reserve power is more profitable than producing with the full capacity. Therefore wind turbines can be down-regulated and sell the differential capacity as the reserve power. In this paper we suggest a model based approach to control wind turbines for active power reference...

  5. Hybrid Active Filter with Variable Conductance for Harmonic Resonance Suppression in Industrial Power Systems

    DEFF Research Database (Denmark)

    Lee, Tzung-Lin; Wang, Yen-Ching; Li, Jian-Cheng

    2015-01-01

    Unintentional series and/or parallel resonances, due to the tuned passive filter and the line inductance, may result in severe harmonic distortion in the industrial power system. This paper presents a hybrid active filter to suppress harmonic resonance and reduce harmonic distortion as well...... expensive. A reasonable trade-off between filtering performances and cost is to use the hybrid active filter. Design consideration are presented and experimental results are provided to validate effectiveness of the proposed method. Furthermore, this paper discusses filtering performances on line impedance...

  6. Mechanical activation of ceramic powders and its influence on the quality of the refractory linings

    International Nuclear Information System (INIS)

    Ceganac, Z.; Acimovic, Z.; Andric, Lj.; Petrov, M.; Mihajlovic, S.

    2003-01-01

    In the paper we present results of the investigation of the influence of mechanical activation of ceramic powders-talc and alumina, on the quality of refractory linings for casting applications. It is shown that additional fine grinding of ceramic powders increases the quality of the refractory lining. Grinding and activation of the particles with various granulations contributes to the creation of the homogenous continuous layer of refractory lining on the sand moulds and cores, as well as on the evaporating polystyrene patterns for applications in the Lost foam casting process. Refractory linings obtained within the activation of particles procedure have better adherence to moulds, cores and evaporating patterns. (Original)

  7. Imprint of DESI fiber assignment on the anisotropic power spectrum of emission line galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Pinol, Lucas [Département de Physique, École Normale Supérieure, Paris (France); Cahn, Robert N. [Lawrence Berkeley National Laboratory, Berkeley, California (United States); Hand, Nick [Department of Astronomy, University of California, Berkeley, California (United States); Seljak, Uroš; White, Martin, E-mail: lucas.pinol@ens.fr, E-mail: rncahn@lbl.gov, E-mail: nhand@berkeley.edu, E-mail: useljak@berkeley.edu, E-mail: mwhite@berkeley.edu [Department of Physics, University of California, Berkeley, California (United States)

    2017-04-01

    The Dark Energy Spectroscopic Instrument (DESI), a multiplexed fiber-fed spectrograph, is a Stage-IV ground-based dark energy experiment aiming to measure redshifts for 29 million Emission-Line Galaxies (ELG), 4 million Luminous Red Galaxies (LRG), and 2 million Quasi-Stellar Objects (QSO). The survey design includes a pattern of tiling on the sky, the locations of the fiber positioners in the focal plane of the telescope, and an observation strategy determined by a fiber assignment algorithm that optimizes the allocation of fibers to targets. This strategy allows a given region to be covered on average five times for a five-year survey, with a typical variation of about 1.5 about the mean, which imprints a spatially-dependent pattern on the galaxy clustering. We investigate the systematic effects of the fiber assignment coverage on the anisotropic galaxy clustering of ELGs and show that, in the absence of any corrections, it leads to discrepancies of order ten percent on large scales for the power spectrum multipoles. We introduce a method where objects in a random catalog are assigned a coverage, and the mean density is separately computed for each coverage factor. We show that this method reduces, but does not eliminate the effect. We next investigate the angular dependence of the contaminated signal, arguing that it is mostly localized to purely transverse modes. We demonstrate that the cleanest way to remove the contaminating signal is to perform an analysis of the anisotropic power spectrum P ( k ,μ) and remove the lowest μ bin, leaving μ > 0 modes accurate at the few-percent level. Here, μ is the cosine of the angle between the line-of-sight and the direction of k-vector . We also investigate two alternative definitions of the random catalog and show that they are comparable but less effective than the coverage randoms method.

  8. DISSECTING THE POWER SOURCES OF LOW-LUMINOSITY EMISSION-LINE GALAXY NUCLEI VIA COMPARISON OF HST-STIS AND GROUND-BASED SPECTRA

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, Anca; Castillo, Christopher A. [Department of Physics and Astronomy, James Madison University, Harrisonburg, VA 22807 (United States); Shields, Joseph C. [Department of Physics and Astronomy, Ohio University, Athens, OH 45701 (United States); Ho, Luis C. [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China); Barth, Aaron J. [Department of Physics and Astronomy, University of California, Irvine, CA 92697-4575 (United States); Filippenko, Alexei V. [Department of Astronomy, University of California, Berkeley, CA 94720-3411 (United States)

    2015-12-01

    Using a sample of ∼100 nearby line-emitting galaxy nuclei, we have built the currently definitive atlas of spectroscopic measurements of Hα and neighboring emission lines at subarcsecond scales. We employ these data in a quantitative comparison of the nebular emission in Hubble Space Telescope (HST) and ground-based apertures, which offer an order-of-magnitude difference in contrast, and provide new statistical constraints on the degree to which transition objects and low-ionization nuclear emission-line regions (LINERs) are powered by an accreting black hole at ≲10 pc. We show that while the small-aperture observations clearly resolve the nebular emission, the aperture dependence in the line ratios is generally weak, and this can be explained by gradients in the density of the line-emitting gas: the higher densities in the more nuclear regions potentially flatten the excitation gradients, suppressing the forbidden emission. The transition objects show a threefold increase in the incidence of broad Hα emission in the high-resolution data, as well as the strongest density gradients, supporting the composite model for these systems as accreting sources surrounded by star-forming activity. The narrow-line LINERs appear to be the weaker counterparts of the Type 1 LINERs, where the low accretion rates cause the disappearance of the broad-line component. The enhanced sensitivity of the HST observations reveals a 30% increase in the incidence of accretion-powered systems at z ≈ 0. A comparison of the strength of the broad-line emission detected at different epochs implies potential broad-line variability on a decade-long timescale, with at least a factor of three in amplitude.

  9. Seismic Response of Power Transmission Tower-Line System Subjected to Spatially Varying Ground Motions

    Directory of Open Access Journals (Sweden)

    Li Tian

    2010-01-01

    Full Text Available The behavior of power transmission tower-line system subjected to spatially varying base excitations is studied in this paper. The transmission towers are modeled by beam elements while the transmission lines are modeled by cable elements that account for the nonlinear geometry of the cables. The real multistation data from SMART-1 are used to analyze the system response subjected to spatially varying ground motions. The seismic input waves for vertical and horizontal ground motions are also generated based on the Code for Design of Seismic of Electrical Installations. Both the incoherency of seismic waves and wave travel effects are accounted for. The nonlinear time history analytical method is used in the analysis. The effects of boundary conditions, ground motion spatial variations, the incident angle of the seismic wave, coherency loss, and wave travel on the system are investigated. The results show that the uniform ground motion at all supports of system does not provide the most critical case for the response calculations.

  10. Development of an induction motor abnormality monitoring system(IMAMS) using power line signal analysis

    International Nuclear Information System (INIS)

    Jung, Jae Cheon

    1997-02-01

    An induction motor abnormality monitoring system using power line signal analysis is developed in this work. Various studies have focused their attention on the detection of particular harmonic frequencies produced from each defect mode of motors. However, these harmonic frequencies are valuable only when the motor has a continuous slip frequency and operate in constant torque/load condition. The basic concept of the system developed in this work is to detect the characteristic harmonic frequencies occurred when the motor is in abnormal state and to compare it with a predetermined setpoint. Based on these analyses, the place and degree of defect can be easily identified. The experimental results under test bench simulation are also introduced. To find out an alternative way to obtain a threshold level independent of slip/torque, with the rotating field theory, the ratio between harmonic current and total current was calculated with the simplified circuit that is equivalent to two abnormal cases, such as the spatial rotor resistance variation and the symmetrical components changes with field. Also, the threshold level calculation was done with performed the rotating field theory. The results show that they are in good agreement with a experimental results. Further studies are undertaken to extend this work to the on-line monitoring and diagnostic system with a likelihood ratio test method for field application

  11. Frequency electromagnetic sounding with industrial power lines on Karelia-Kola geotraverse

    Directory of Open Access Journals (Sweden)

    А. Н. Шевцов

    2017-04-01

    Full Text Available The paper describes theory, method and first experimental results of research on the interaction between electromagnetic waves of extremely low and ultra low frequency (0.1-200 Hz, the Earth crust and ionosphere in the field of two mutually orthogonal industrial power lines, 109 and 120 km long, in the course of FENICS experiment (Fennoscandian Electrical conductivity from Natural and Induction Control Source soundings. The main focus was on the observation results along the line of Karelia-Kola geotraverse over a distance of 700 km from the source. High horizontal homogeneity of geoelectrical lithosphere section has been detected in the eastern part of the Baltic shield at depth range from 10-15 to 50-70 km. Parameters of «regular» lithosphere section have been specified to the depth of 60-70 km. As a result of inverse problem solution for the western part of Karelia and Central Finland, a zone of decreased transverse resistivity has been detected at the depth of 50-60 km, corresponding to the area, detected by seismic methods, where Moho boundary reaches the same depth.

  12. On-line water chemistry monitoring for corrosion prevention in ageing nuclear power plants

    International Nuclear Information System (INIS)

    Aaltonen, P.; Jaernstroem, R.; Kvarnstroem, R.; Chanfreau, E.

    1991-01-01

    General corrosion and consequently radiation buildup in nuclear power plants are controlled by the selection of material and the chemical environment. In power plants useful information concerning the kinetics of chemical reactions can be obtained by using high temperature, high pressure measurements for pH, conductivity and electrochemical potentials (ECP) of construction materials or redox-potential. The rates of general or uniform corrosion of materials in contact with the primary coolant are quite low and do not compromise the integrity of the primary circuit. Chemistry control should be applied in the first hand to minimize the dissolution and the transport and subsequent deposition of activated corrosion products to out-of-core regions. A computerized monitoring system for high temperature high pressure pH and electrochemical potential (ECP) has been in continuous use at the Loviisa power plant since 1988. Special emphasis has been put on learning the effect of pH and ECP control during cooldown process in order to further reduce background radiation buildup. During the shutdown for refueling outage in summer 1989 the high temperature water chemistry parameters were monitored. In addition to the high temperature water chemistry parameters concentrations of dissolved corrosion products as well as the activities of the corrosion products were measured. In this paper the results obtained through simultaneous monitoring of water chemistry parameters and concentrations of dissolved corrosion products as well as the activity measurements are presented and discussed. (author)

  13. Single Phase Passive Rectification Versus Active Rectification Applied to High Power Stirling Engines

    Science.gov (United States)

    Santiago, Walter; Birchenough, Arthur G.

    2006-01-01

    Stirling engine converters are being considered as potential candidates for high power energy conversion systems required by future NASA explorations missions. These types of engines typically contain two major moving parts, the displacer and the piston, in which a linear alternator is attached to the piston to produce a single phase sinusoidal waveform at a specific electric frequency. Since all Stirling engines perform at low electrical frequencies (less or equal to 100 Hz), space explorations missions that will employ these engines will be required to use DC power management and distribution (PMAD) system instead of an AC PMAD system to save on space and weight. Therefore, to supply such DC power an AC to DC converter is connected to the Stirling engine. There are two types of AC to DC converters that can be employed, a passive full bridge diode rectifier and an active switching full bridge rectifier. Due to the inherent line inductance of the Stirling Engine-Linear Alternator (SE-LA), their sinusoidal voltage and current will be phase shifted producing a power factor below 1. In order to keep power the factor close to unity, both AC to DC converters topologies will implement power factor correction. This paper discusses these power factor correction methods as well as their impact on overall mass for exploration applications. Simulation results on both AC to DC converters topologies with power factor correction as a function of output power and SE-LA line inductance impedance are presented and compared.

  14. New Keypoint Matching Method Using Local Convolutional Features for Power Transmission Line Icing Monitoring

    Directory of Open Access Journals (Sweden)

    Qiangliang Guo

    2018-02-01

    Full Text Available Power transmission line icing (PTLI problems, which cause tremendous damage to the power grids, has drawn much attention. Existing three-dimensional measurement methods based on binocular stereo vision was recently introduced to measure the ice thickness in PTLI, but failed to meet requirements of practical applications due to inefficient keypoint matching in the complex PTLI scene. In this paper, a new keypoint matching method is proposed based on the local multi-layer convolutional neural network (CNN features, termed Local Convolutional Features (LCFs. LCFs are deployed to extract more discriminative features than the conventional CNNs. Particularly in LCFs, a multi-layer features fusion scheme is exploited to boost the matching performance. Together with a location constraint method, the correspondence of neighboring keypoints is further refined. Our approach achieves 1.5%, 5.3%, 13.1%, 27.3% improvement in the average matching precision compared with SIFT, SURF, ORB and MatchNet on the public Middlebury dataset, and the measurement accuracy of ice thickness can reach 90.9% compared with manual measurement on the collected PTLI dataset.

  15. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    Directory of Open Access Journals (Sweden)

    Zheng Li

    2010-12-01

    Full Text Available This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 is chosen as the core of control system. Visible light and thermal infrared cameras are installed to obtain the video and temperature information, and the communication system is based on wireless LAN TCP/IP protocol. A prototype robot was developed with careful considerations of mobility. The new sensor configuration is used for the claw to grasp the overhead ground wires. The bridge is installed in the torsion tower for the robot easy to cross obstacles. The new posture plan is proposed for obstacles cleaning in the torsion tower. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  16. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    Directory of Open Access Journals (Sweden)

    Zheng Li

    2011-01-01

    Full Text Available This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 is chosen as the core of control system. Visible light and thermal infrared cameras are installed to obtain the video and temperature information, and the communication system is based on wireless LAN TCP/IP protocol. A prototype robot was developed with careful considerations of mobility. The new sensor configuration is used for the claw to grasp the overhead ground wires. The bridge is installed in the torsion tower for the robot easy to cross obstacles. The new posture plan is proposed for obstacles cleaning in the torsion tower. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  17. Development of on-line operator aid system (OASYSTM) for nuclear power plants

    International Nuclear Information System (INIS)

    Kang, Ki Sig; Choi, Seong Soo; Kim, Han Gon; Chang, Soon Heung; Jeong, Hee Kyo; Yi, Chul Un

    1994-01-01

    In this paper, the development of On - line operator Aid SYStem (OASYS TM ) are discussed by focusing attention on the importance of the operator's role for nuclear power plants. The OASYS TM is under development to support the operator's decision making process and to enhance the safety of a nuclear power plant by providing the plant operators with timely and proper guideline during abnormal and emergency conditions. The OASYS TM has capabilities for the signal validation/management, the alarm processing, the failure diagnosis using abnormal operating procedures, and the dynamic tracking of emergency operating procedures using function restoration guidelines and optimal recovery guidelines with a series of complex logic steps covering a broad spectrum of event sequences. The proposed system is being implemented on a SUN-4/75 Workstation using C and Quintus TM prolog language. For verification studies a full-scope real-time simulator is being used. Test results show that the OASYS TM is capable of diagnosing a plant failure quickly and providing an operator guideline with fast response time. After verification the OASYS TM will be installed in the simulator II of Kori nuclear training center

  18. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators

    Directory of Open Access Journals (Sweden)

    Dotsinsky Ivan

    2005-11-01

    Full Text Available Abstract Background Public access defibrillators (PADs are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Method Moving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed. This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling. Results The proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection. Conclusion The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression.

  19. Quantitative on-line age monitoring system for power generation industries

    International Nuclear Information System (INIS)

    Mukhopadhyay, N.K.; Dutta, B.K.; Kushwaha, H.S.

    1994-01-01

    The degradation effect of various components of power generation industries is an important information for safe and cost effective running of the plant. Among the various such aging effects, fatigue, fatigue creep interaction and crack growth are commonly responsible for most of the failures. Information about various aging effects help in assessing structural degradation of the components. This provides actual plant transients to future designers, guidelines for in-service inspection and maintenance programmes and may also support future life extension of a power plant. In the present paper, development of a quantitative on-line age monitoring methodology using the available plant instrumentations is presented. Green's function technique is used to convert plant data to temperature and stress versus time data. Fatigue usage factor is computed using rain flow cycle counting algorithm using the material fatigue data. The effect of creep is considered adopting life fraction rule using material creep data. Crack growth rate is predicted using linear elastic fracture mechanics and time dependent C t approach. The present paper describes the detailed steps of this methodology, the development of various codes and the case studies carried out. (author). 3 figs

  20. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators.

    Science.gov (United States)

    Dotsinsky, Ivan

    2005-11-26

    Public access defibrillators (PADs) are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Moving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed). This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC) for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling. The proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection. The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression.

  1. Compensating active power imbalances in power system with large-scale wind power penetration

    DEFF Research Database (Denmark)

    Basit, Abdul; Hansen, Anca Daniela; Altin, Müfit

    2016-01-01

    Large-scale wind power penetration can affectthe supply continuity in the power system. This is a matterof high priority to investigate, as more regulating reservesand specified control strategies for generation control arerequired in the future power system with even more highwind power penetrat...

  2. Bird on the wire: Landscape planning considering costs and benefits for bird populations coexisting with power lines.

    Science.gov (United States)

    D'Amico, Marcello; Catry, Inês; Martins, Ricardo C; Ascensão, Fernando; Barrientos, Rafael; Moreira, Francisco

    2018-02-24

    Power-line grids are increasingly expanding worldwide, as well as their negative impacts on avifauna, namely the direct mortality through collision and electrocution, the reduction of breeding performance, and the barrier effect. On the other hand, some bird species can apparently benefit from the presence of power lines, for example perching for hunting purposes or nesting on electricity towers. In this perspective essay, we reviewed the scientific literature on both costs and benefits for avifauna coexisting with power lines. Overall, we detected a generalized lack of studies focusing on these costs or benefits at a population level. We suggest that a switch in research approach to a larger spatio-temporal scale would greatly improve our knowledge about the actual effects of power lines on bird populations. This research approach would facilitate suitable landscape planning encompassing both mitigation of costs and promotion of benefits for bird populations coexisting with power lines. For example, the strategic route planning of electricity infrastructures would limit collision risk or barrier effects for threatened bird populations. Concurrently, this strategic route planning would promote the range expansion of threatened populations of other bird species, by providing nesting structures in treeless but potentially suitable landscapes. We suggest establishing a collaborative dialogue among the scientific community, governments, and electricity companies, with the aim to produce a win-win scenario in which both biodiversity conservation and infrastructure development are integrated in a common strategy.

  3. Social power and approach-related neural activity

    NARCIS (Netherlands)

    M.A.S. Boksem (Maarten); R. Smolders (Ruud); D. de Cremer (David)

    2009-01-01

    textabstractIt has been argued that power activates a general tendency to approach whereas powerlessness activates a tendency to inhibit. The assumption is that elevated power involves reward-rich environments, freedom and, as a consequence, triggers an approach-related motivational orientation and

  4. Experience and development of on-line BWR surveillance system at Onagawa nuclear power station unit-1

    International Nuclear Information System (INIS)

    Kishi, A.; Chiba, K.; Kato, K.; Ebata, S.; Ando, Y.; Sakamoto, H.

    1986-01-01

    ONAGAWA nuclear power station Unit-1 (Tohoku Electric Power Co.) is a BWR-4 nuclear power station of 524 MW electric power which started commercial operation in June 1984. To attain high reliability and applicability for ONAGAWA-1, Tohoku Electric Power Co. and Toshiba started a Research and Development project on plant surveillance and diagnosis from April 1982. Main purposes of this project are to: (1) Develop an on-line surveillance system and acquire its operating experience at a commercial BWR, (2) Assist in plant operation and maintenance by data acquisition and analysis, (3) Develop a new technique for plant surveillance and diagnosis. An outline of the project, operating experience gained from the on-line surveillance system and an introduction to new diagnosis techniques are reported in this paper. (author)

  5. Measurement of borders in power transmission lines; Medicao de fronteira em linhas de transmissao

    Energy Technology Data Exchange (ETDEWEB)

    Doria, Celso [Bandeirante Energia S.A., Sao Paulo, SP (Brazil)

    2001-07-01

    The creation of Bandeirantes Energia S/A, which is a energy distributor company and at the same time one of the four originated companies from the division of ELETROPAULO Eletricidade S/A, generated the need of consumed energy measurements. Different from a previous situation, which had been accomplished in the 230, 345 and 440 Kv transformer stations. With the aggravating of having been created two distribution companies by this division, which later possessed transmission lines in common finishing a border scenery of 88/138 kv in connection with CTEEP, EPTE, Furnas in station terminals and ELETROPAULO Metropolitana in transmission lines. In order to measure the consumed energy it has been necessary to install meters in all energy entrance subsystems, but there were certain cases for which part of the energy had been absorbed by other distribution company, some times before the connection with Bandeirantes some times after this connection to have been done. For these cases, it has been necessary to install meters at de middle of the line, it means installed meters at the border between the two companies. In February of 1999, they were initiate the studies of viability for these measurements implantation in all of the interface points among Bandeirantes and the other concessionaires, based on the premise that from 01/01/2000 on all the consumed energy by the company should be measured. In the end of May of 1999, with the design final definitions the studies were finished, after that, it has been started the equipment purchases and the actions to hire companies to execute these activities. Finally, in the last week of August of 1999 the construction activities were initiated and the circuits were energized in December of that year.

  6. Motorized Activity on Legacy Seismic Lines: A Predictive Modeling Approach to Prioritize Restoration Efforts.

    Science.gov (United States)

    Hornseth, M L; Pigeon, K E; MacNearney, D; Larsen, T A; Stenhouse, G; Cranston, J; Finnegan, L

    2018-05-11

    Natural regeneration of seismic lines, cleared for hydrocarbon exploration, is slow and often hindered by vegetation damage, soil compaction, and motorized human activity. There is an extensive network of seismic lines in western Canada which is known to impact forest ecosystems, and seismic lines have been linked to declines in woodland caribou (Rangifer tarandus caribou). Seismic line restoration is costly, but necessary for caribou conservation to reduce cumulative disturbance. Understanding where motorized activity may be impeding regeneration of seismic lines will aid in prioritizing restoration. Our study area in west-central Alberta, encompassed five caribou ranges where restoration is required under federal species at risk recovery strategies, hence prioritizing seismic lines for restoration is of immediate conservation value. To understand patterns of motorized activity on seismic lines, we evaluated five a priori hypotheses using a predictive modeling framework and Geographic Information System variables across three landscapes in the foothills and northern boreal regions of Alberta. In the northern boreal landscape, motorized activity was most common in dry areas with a large industrial footprint. In highly disturbed areas of the foothills, motorized activity on seismic lines increased with low vegetation heights, relatively dry soils, and further from forest cutblocks, while in less disturbed areas of the foothills, motorized activity on seismic lines decreased proportional to seismic line density, slope steepness, and white-tailed deer abundance, and increased proportional with distance to roads. We generated predictive maps of high motorized activity, identifying 21,777 km of seismic lines where active restoration could expedite forest regeneration.

  7. CNEN activities and brazilian nuclear power policy

    International Nuclear Information System (INIS)

    Costa, E.M. da

    1989-01-01

    The goal of the brazilian policy in nuclear power is to provide its use in a pacific way to promote the well being of our people. It is intended, as well, to finish the construction of Angra II and III and proceed with the implementation of the nuclear fuel cycle, progressively fomenting its nationalization. (A.C.A.S.)

  8. The magnetic field near power lines in the Moscow region: the results of measurements and their analyze

    Directory of Open Access Journals (Sweden)

    Prokofyeva A.S.

    2014-12-01

    Full Text Available The aim: to analyze the real power frequency magnetic field (50 Hz values near power lines. The material. Long-term measurements of the power frequency magnetic field (50 Hz near power lines of 110 kV, 220 kVand 500 kVin the Moscow region. Methods. Measurements were made by tracks which were perpendicular to the wires. Length of tracks was up to 40 m. Sensor of measurer was located on 1.8 m under the ground. General quantity of measurement points were 1103. The results. Was obtained general characteristics of real values of strength of electric field and values of magnetic flux density depending to distance to the projection last wire near power lines. Conclusion. Analysis of the results has the values of the magnetic field of power lines correspond to the Russian rules in all cases. Using additional World Health Organization safety criteria for magnetic fields (the class of carcinogenic risks 2B requires the expansion of the health safety zone 2-3 times.

  9. Social power and approach-related neural activity.

    Science.gov (United States)

    Boksem, Maarten A S; Smolders, Ruud; De Cremer, David

    2012-06-01

    It has been argued that power activates a general tendency to approach whereas powerlessness activates a tendency to inhibit. The assumption is that elevated power involves reward-rich environments, freedom and, as a consequence, triggers an approach-related motivational orientation and attention to rewards. In contrast, reduced power is associated with increased threat, punishment and social constraint and thereby activates inhibition-related motivation. Moreover, approach motivation has been found to be associated with increased relative left-sided frontal brain activity, while withdrawal motivation has been associated with increased right sided activations. We measured EEG activity while subjects engaged in a task priming either high or low social power. Results show that high social power is indeed associated with greater left-frontal brain activity compared to low social power, providing the first neural evidence for the theory that high power is associated with approach-related motivation. We propose a framework accounting for differences in both approach motivation and goal-directed behaviour associated with different levels of power.

  10. Cytotoxic activity of methanol extracts from Basidiomycete mushrooms on murine cancer cell lines.

    Science.gov (United States)

    Tomasi, S; Lohézic-Le Dévéhat, F; Sauleau, P; Bézivin, C; Boustie, J

    2004-04-01

    Crude methanol extracts of 58 mushroom species were screened for their cytotoxic activities against two murine cancer cell lines, L1210 and 3LL, using the tetrazolium assay. A majority of extracts (74%) exhibited IC50 > 100 microg/ml against both cell lines. A most marked activity against one of the cell lines was noted for nine species (14% of the tested species). While Amanitales and Russulales tested were not found active, Polyporales and Boletales gave better results. Four species exhibited a significant cytotoxic activity (IC50 Suillus granulatus, S. luteus). The last one had never been investigated for its cytotoxic compounds before.

  11. Antioxidant activity assays on-line with liquid chromatography

    NARCIS (Netherlands)

    Niederlander, Harm A. G.; van Beek, Teris A.; Bartasiute, Aiste; Koieva, Irina I.

    2008-01-01

    Screening for antioxidants requires simple in vitro model systems to investigate antioxidant activity. High resolution screening (HRS), combining a separation technique like HPLC with fast post-column (bio)chemical detection can rapidly pinpoint active compounds in complex mixtures. In this paper

  12. On-line vibration and loose parts monitoring of nuclear power stations as a preventive maintenance tool

    International Nuclear Information System (INIS)

    An equipment for on-line monitoring of vibrations and loose parts of nuclear power plants is described. The unit consists of piezoelectric transducers, preamplifiers, a data processor, and peripherals. It secures on-line measurement without interfering with the operation of the power plant. A diagram is given showing the monitor of vibrations and loose parts for pressurized water reactors and the Spectra-Scan equipment for the automatic recording and computer processing of noise signals is described. A survey is given of diagnostic methods for internal vibrations, noise and oscillations and procedures for the analysis of recordings are described. The experiences of Atomica International with the observation of vibrations in nuclear power plants are described and an economic assessment is presented of the efficiency of on-line monitoring of these vibrations. A cost-benefit analysis is made of such equipment which justifies their introduction. (B.S.)

  13. Removal of power line interference of space bearing vibration signal based on the morphological filter and blind source separation

    Science.gov (United States)

    Dong, Shaojiang; Sun, Dihua; Xu, Xiangyang; Tang, Baoping

    2017-06-01

    Aiming at the problem that it is difficult to extract the feature information from the space bearing vibration signal because of different noise, for example the running trend information, high-frequency noise and especially the existence of lot of power line interference (50Hz) and its octave ingredients of the running space simulated equipment in the ground. This article proposed a combination method to eliminate them. Firstly, the EMD is used to remove the running trend item information of the signal, the running trend that affect the signal processing accuracy is eliminated. Then the morphological filter is used to eliminate high-frequency noise. Finally, the components and characteristics of the power line interference are researched, based on the characteristics of the interference, the revised blind source separation model is used to remove the power line interferences. Through analysis of simulation and practical application, results suggest that the proposed method can effectively eliminate those noise.

  14. Nuclear power plant construction activity, 1986

    International Nuclear Information System (INIS)

    1987-01-01

    Cost estimates, chronological data on construction progress, and the physical characteristics of nuclear units in commercial operation and units in the construction pipeline as of December 31, 1986, are presented. This report, which is updated annually, was prepared to provide an overview of the nuclear power plant construction industry. The report contains information on the status of nuclear generating units, average construction costs and lead-times, and construction milestones for individual reactors

  15. The activity-integrated method for quality assessment of reduning injection by on-line DPPH-CE-DAD.

    Directory of Open Access Journals (Sweden)

    Yan-xu Chang

    Full Text Available A sensitive on-line DPPH-CE-DAD method was developed and validated for both screening and determining the concentration of seven antioxidants of Reduning injection. The pH and concentrations of buffer solution, SDS, β-CD and organic modifier were studied for the detection of DPPH and seven antioxidants. By on-line mixing DPPH and sample solution, a DPPH-CE method for testing the antioxidant activity of the complex matrix was successfully established and used to screen the antioxidant components of Reduning injection. Then, antioxidant components including caffeic acid, isochlorogenic acid A, isochlorogenic acid B, isochlorogenic acid C, chlorogenic acid, neochlorogenic acid and cryptochlorogenic acid were quantified by the newly established CE-DAD method. Finally, the total antioxidant activity and the multiple active components were selected as markers to evaluate the quality of Reduning injection. The results demonstrated that the on-line DPPH-CE-DAD method was reagent-saving, rapid and feasible for on-line simultaneous determination of total pharmacological activity and contents of multi-components samples. It was also a powerful method for evaluating the quality control and mechanism of action of TCM injection.

  16. Technical and economical optimisation of overhead power distribution line lightning protection

    Energy Technology Data Exchange (ETDEWEB)

    Katic, N.A. [Elektrovojvodina Power Distribution Co., Nori Sad (Yugoslavia); Savic, M.S. [University of Belgrade (Yugoslavia). Faculty of Electrical Engineering

    1998-05-01

    The existing methodology for overhead line lightning protection design does not take into account customer and utility costs of line outages. In the paper a new concept of line lightning protection design based on economic optimisation is presented. Different tower types are analysed and for various undelivered energy participation factors optimal line design suggested. In line lightning flashover rate estimation both direct and induced surges are analysed. (author)

  17. THE PHASE REACTOR INDUCTANCE SELECTION TECHNIQUE FOR POWER ACTIVE FILTER

    Directory of Open Access Journals (Sweden)

    D. V. Tugay

    2016-12-01

    Full Text Available Purpose. The goal is to develop technique of the phase inductance power reactors selection for parallel active filter based on the account both low-frequency and high-frequency components of the electromagnetic processes in a power circuit. Methodology. We have applied concepts of the electrical circuits theory, vector analysis, mathematical simulation in Matlab package. Results. We have developed a new technique of the phase reactors inductance selection for parallel power active filter. It allows us to obtain the smallest possible value of THD network current. Originality. We have increased accuracy of methods of the phase reactor inductance selection for power active filter. Practical value. The proposed technique can be used in the design and manufacture of the active power filter for real objects of energy supply.

  18. Adaptive settings of distance relay for MOV-protected series compensated line with distributed capacitance considering wind power

    Science.gov (United States)

    Sivov, Oleg Viktorovich

    Series compensated lines are protected from overvoltage by metal-oxide-varistors (MOVs) connected in parallel with the capacitor bank. The nonlinear characteristics of MOV devices add complexity to fault analysis and distance protection operation. During faults, the impedance of the line is modified by an equivalent impedance of the parallel MOV/capacitor circuit, which affects the distance protection. The intermittent wind generation introduces additional complexity to the system performance and distance protection. Wind variation affects the fault current level and equivalent MOV/capacitor impedance during a fault, and hence the distance relay operation. This thesis studies the impact of the intermittent wind power generation on the operation of MOV during faults. For the purpose of simulation, an equivalent wind farm model is proposed to generate a wind generation profile using wind farm generation from California independent system operator (ISO) as a guide for wind power variation to perform the study. The IEEE 12-bus test system is modified to include MOV-protected series capacitor and the equivalent wind farm model. The modified test system is simulated in the MATLAB/Simulink environment. The study has been achieved considering three phase and single line to ground (SLG) faults on the series compensated line to show the effect of wind variation on the MOV operation. This thesis proposes an adaptive setting method for the mho relay distance protection of series compensated line considering effects of wind power variation and MOV operation. The distributed parameters of a transmission line are taken into account to avoid overreaching and underreaching of distance relays. The study shows that variable wind power affects system power flow and fault current in the compensated line during a fault which affects the operation of MOVs for different fault conditions. The equivalent per-phase impedance of the MOV/capacitor circuit has an effect on the system operation

  19. Calculation of Voltages in Electric Power Transmission Lines During Historic Geomagnetic Storms: An Investigation Using Realistic Earth Impedances

    Science.gov (United States)

    Lucas, Greg M.; Love, Jeffrey J.; Kelbert, Anna

    2018-02-01

    Commonly, one-dimensional (1-D) Earth impedances have been used to calculate the voltages induced across electric power transmission lines during geomagnetic storms under the assumption that much of the three-dimensional structure of the Earth gets smoothed when integrating along power transmission lines. We calculate the voltage across power transmission lines in the mid-Atlantic region with both regional 1-D impedances and 64 empirical 3-D impedances obtained from a magnetotelluric survey. The use of 3-D impedances produces substantially more spatial variance in the calculated voltages, with the voltages being more than an order of magnitude different, both higher and lower, than the voltages calculated utilizing regional 1-D impedances. During the March 1989 geomagnetic storm 62 transmission lines exceed 100 V when utilizing empirical 3-D impedances, whereas 16 transmission lines exceed 100 V when utilizing regional 1-D impedances. This demonstrates the importance of using realistic impedances to understand and quantify the impact that a geomagnetic storm has on power grids.

  20. Calculation of voltages in electric power transmission lines during historic geomagnetic storms: An investigation using realistic earth impedances

    Science.gov (United States)

    Lucas, Greg M.; Love, Jeffrey J.; Kelbert, Anna

    2018-01-01

    Commonly, one-dimensional (1-D) Earth impedances have been used to calculate the voltages induced across electric power transmission lines during geomagnetic storms under the assumption that much of the three-dimensional structure of the Earth gets smoothed when integrating along power transmission lines. We calculate the voltage across power transmission lines in the mid-Atlantic region with both regional 1-D impedances and 64 empirical 3-D impedances obtained from a magnetotelluric survey. The use of 3-D impedances produces substantially more spatial variance in the calculated voltages, with the voltages being more than an order of magnitude different, both higher and lower, than the voltages calculated utilizing regional 1-D impedances. During the March 1989 geomagnetic storm 62 transmission lines exceed 100 V when utilizing empirical 3-D impedances, whereas 16 transmission lines exceed 100 V when utilizing regional 1-D impedances. This demonstrates the importance of using realistic impedances to understand and quantify the impact that a geomagnetic storm has on power grids.

  1. Kertész line of thermally activated breakdown phenomena

    KAUST Repository

    Yoshioka, Naoki; Kun, Ferenc; Ito, Nobuyasu

    2010-01-01

    Based on a fiber bundle model we substantially extend the phase-transition analogy of thermally activated breakdown of homogeneous materials. We show that the competition of breaking due to stress enhancement and due to thermal fluctuations leads

  2. Mechanical Implementation and Simulation of MoboLab, A Mobile Robot for Inspection of Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mahmud Saadat Foumani

    2008-11-01

    Full Text Available This paper describes the first phase in development of a mobile robot that can navigate aerial power transmission lines completely unattended by human operator. Its ultimate purpose is to automate inspection of power transmission lines and their equipments. The authors have developed a scaled functional model of such a mobile robot with a preliminary simple computer based on-off controller. MoboLab (Mobile Laboratory navigates a power transmission line between two strain towers. It can maneuver over obstructions created by line equipments such as insulators, warning spheres, dampers, and spacer dampers. It can also easily negotiate the towers by its three flexible arms. MoboLab has an internal main screw which enables the robot to move itself or its two front and rear arms independently through changing gripped points. When the front arm gets close to an obstacle, the arm detaches from the line and goes down, the robot moves forward, the arm passes the obstacle and grippes the line again. In a same way another arms pass the obstacle.

  3. Overvoltage and Insulation Coordination of Overhead Lines in Multiple-Terminal MMC-HVDC Link for Wind Power Delivery

    Directory of Open Access Journals (Sweden)

    Huiwen He

    2017-01-01

    Full Text Available The voltage-sourced converter-based HVDC link, including the modular multilevel converter (MMC configuration, is suitable for wind power, photovoltaic energy, and other kinds of new energy delivery and grid-connection. Current studies are focused on the MMC principles and controls and few studies have been done on the overvoltage of transmission line for the MMC-HVDC link. The main reason is that environmental factors have little effect on DC cables and the single-phase/pole fault rate is low. But if the cables were replaced by the overhead lines, although the construction cost of the project would be greatly reduced, the single-pole ground fault rate would be much higher. This paper analyzed the main overvoltage types in multiple-terminal MMC-HVDC network which transmit electric power by overhead lines. Based on ±500 kV multiple-terminal MMC-HVDC for wind power delivery project, the transient simulation model was built and the overvoltage types mentioned above were studied. The results showed that the most serious overvoltage was on the healthy adjacent line of the faulty line caused by the fault clearing of DC breaker. Then the insulation coordination for overhead lines was conducted according to the overvoltage level. The recommended clearance values were given.

  4. The Power Behind the Controversy: Understanding Local Policy Elites' Perceptions on the Benefits and Risks Associated with High Voltage Power Line Installation in the State of Arkansas

    Science.gov (United States)

    Moyer, Rachael M.

    Following a proposal for the installation of high voltage power lines in northwest Arkansas, a controversial policy debate emerged. Proponents of the transmission line argue that such an installation is inevitable and necessary to efficiently and reliably support the identified electric load in the region. Opponents claim that the lines will degrade the natural environment and hamper the tourism-based local economy in affected regions, notably in Ozark Mountain areas. This study seeks to understand how local policy elites perceive the benefits and risks associated with proposed transmission lines, which is a critical step in comprehending the formation and changes of related government policies. First, based upon the dual process theory of judgment, this study systematically investigates the triadic relationships between (a) more profound personal value predispositions, (b) affects and feelings, and (c) perceived benefits and risks related to the proposed installation of high voltage power lines among local policy elites in the state of Arkansas. Next, this study focuses more specifically on the role of value predispositions, specific emotional dimensions of affect heuristics, and perceptions pertaining to high voltage power line risks and benefits. Using original data collected from a statewide Internet survey of 420 local leaders and key policymakers about their opinions on the related issues, other factors claimed by previous literature, including trust, knowledge level, and demographic characteristics are considered. Analytical results suggest that grid-group cultural predispositions, as deeply held core values within local policy elites' individual belief systems, both directly and indirectly -- through affective feelings -- shape perceived utility associated with the installation of high voltage power lines. Recognizing that risk perceptions factor into policy decisions, some practical considerations for better designing policy addressing controversial issues

  5. Self-tuning wireless power transmission scheme based on on-line scattering parameters measurement and two-side power matching.

    Science.gov (United States)

    Luo, Yanting; Yang, Yongmin; Chen, Zhongsheng

    2014-04-10

    Sub-resonances often happen in wireless power transmission (WPT) systems using coupled magnetic resonances (CMR) due to environmental changes, coil movements or component degradations, which is a serious challenge for high efficiency power transmission. Thus self-tuning is very significant to keep WPT systems following strongly magnetic resonant conditions in practice. Traditional coupled-mode ways is difficult to solve this problem. In this paper a two-port power wave model is presented, where power matching and the overall systemic power transmission efficiency are firstly defined by scattering (S) parameters. Then we propose a novel self-tuning scheme based on on-line S parameters measurements and two-side power matching. Experimental results testify the feasibility of the proposed method. These findings suggest that the proposed method is much potential to develop strongly self-adaptive WPT systems with CMR.

  6. Converging cylindrical magnetohydrodynamic shock collapse onto a power-law-varying line current

    KAUST Repository

    Mostert, W.

    2016-03-16

    We investigate the convergence behaviour of a cylindrical, fast magnetohydrodynamic (MHD) shock wave in a neutrally ionized gas collapsing onto an axial line current that generates a power law in time, azimuthal magnetic field. The analysis is done within the framework of a modified version of ideal MHD for an inviscid, non-dissipative, neutrally ionized compressible gas. The time variation of the magnetic field is tuned such that it approaches zero at the instant that the shock reaches the axis. This configuration is motivated by the desire to produce a finite magnetic field at finite shock radius but a singular gas pressure and temperature at the instant of shock impact. Our main focus is on the variation with shock radius, as, of the shock Mach number and pressure behind the shock as a function of the magnetic field power-law exponent, where gives a constant-in-time line current. The flow problem is first formulated using an extension of geometrical shock dynamics (GSD) into the time domain to take account of the time-varying conditions ahead of the converging shock, coupled with appropriate shock-jump conditions for a fast, symmetric MHD shock. This provides a pair of ordinary differential equations describing both and the time evolution on the shock, as a function of, constrained by a collapse condition required to achieve tuned shock convergence. Asymptotic, analytical results for and are obtained over a range of for general, and for both small and large . In addition, numerical solutions of the GSD equations are performed over a large range of, for selected parameters using . The accuracy of the GSD model is verified for some cases using direct numerical solution of the full, radially symmetric MHD equations using a shock-capturing method. For the GSD solutions, it is found that the physical character of the shock convergence to the axis is a strong function of . For μ≤0.816, and both approach unity at shock impact owing to the dominance of the strong

  7. Ultrasound line-by-line scanning method of spatial-temporal active cavitation mapping for high-intensity focused ultrasound.

    Science.gov (United States)

    Ding, Ting; Zhang, Siyuan; Fu, Quanyou; Xu, Zhian; Wan, Mingxi

    2014-01-01

    This paper presented an ultrasound line-by-line scanning method of spatial-temporal active cavitation mapping applicable in a liquid or liquid filled tissue cavities exposed by high-intensity focused ultrasound (HIFU). Scattered signals from cavitation bubbles were obtained in a scan line immediately after one HIFU exposure, and then there was a waiting time of 2 s long enough to make the liquid back to the original state. As this pattern extended, an image was built up by sequentially measuring a series of such lines. The acquisition of the beamformed radiofrequency (RF) signals for a scan line was synchronized with HIFU exposure. The duration of HIFU exposure, as well as the delay of the interrogating pulse relative to the moment while HIFU was turned off, could vary from microseconds to seconds. The feasibility of this method was demonstrated in tap-water and a tap-water filled cavity in the tissue-mimicking gelatin-agar phantom as capable of observing temporal evolutions of cavitation bubble cloud with temporal resolution of several microseconds, lateral and axial resolution of 0.50 mm and 0.29 mm respectively. The dissolution process of cavitation bubble cloud and spatial distribution affected by cavitation previously generated were also investigated. Although the application is limited by the requirement for a gassy fluid (e.g. tap water, etc.) that allows replenishment of nuclei between HIFU exposures, the technique may be a useful tool in spatial-temporal cavitation mapping for HIFU with high precision and resolution, providing a reference for clinical therapy. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. [Apoptosis of human lung carcinoma cell line GLC-82 induced by high power electromagnetic pulse].

    Science.gov (United States)

    Cao, Xiao-zhe; Zhao, Mei-lan; Wang, De-wen; Dong, Bo

    2002-09-01

    Electromagnetic pulse (EMP) could be used for sterilization of food and the efficiency is higher than 2450 MHz continuous microwave done. This study was designed to evaluate the effect of electromagnetic pulse (EMP) on apoptosis of human lung carcinoma cell line GLC-82, so that to explore and develop therapeutic means for cancer. The injury changes in GLC-82 cells after irradiated with EMP (electric field intensity was 60 kV/m, 5 pulses/2 min) were analyzed by cytometry, MTT chronometry, and flow cytometry. The immunohistochemical SP staining was used to determine the expressions of bcl-2 protein and p53 protein. The stained positive cells were analyzed by CMIAS-II image analysis system at a magnification 400. All data were analyzed by SPSS8.0 software. EMP could obviously inhibited proliferation and activity of lung carcinoma cell line GLC-82. The absorbance value (A570) of MTT decreased immediately, at 0 h, 1 h, and 6 h after the GLC-82 cells irradiated by EMP as compared with control group. The highest apoptosis rate was found to reach 13.38% by flow cytometry at 6 h after EMP irradiation. Down-regulation of bcl-2 expression and up-regulation of p53 expression were induced by EMP. EMP promotes apoptosis of GLC-82 cells. At same time, EMP can down-regulate bcl-2 expression and up-regulate p53 expression in GLC-82 cells. The bcl-2 and the p53 protein may involve the apoptotic process.

  9. Grid-Connected Photovoltaic System with Active Power Filtering Functionality

    Directory of Open Access Journals (Sweden)

    Joaquín Vaquero

    2018-01-01

    Full Text Available Solar panels are an attractive and growing source of renewable energy in commercial and residential applications. Its use connected to the grid by means of a power converter results in a grid-connected photovoltaic system. In order to optimize this system, it is interesting to integrate several functionalities into the power converter, such as active power filtering and power factor correction. Nonlinear loads connected to the grid generate current harmonics, which deteriorates the mains power quality. Active power filters can compensate these current harmonics. A photovoltaic system with added harmonic compensation and power factor correction capabilities is proposed in this paper. A sliding mode controller is employed to control the power converter, implemented on the CompactRIO digital platform from National Instruments Corporation, allowing user friendly operation and easy tuning. The power system consists of two stages, a DC/DC boost converter and a single-phase inverter, and it is able to inject active power into the grid while compensating the current harmonics generated by nonlinear loads at the point of common coupling. The operation, design, simulation, and experimental results for the proposed system are discussed.

  10. Wireless Power Supply via Coupled Magnetic Resonance for on-line Monitoring Wireless Sensor of High-voltage Electrical Equipment

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Yudi, Xiao

    2016-01-01

    On-line monitoring of high-voltage electrical equipment (HV-EE) aiming to detect faults effectively has become crucial to avoid serious accidents. Moreover, highly reliable power supplies are the key component for the wireless sensors equipped in such on-line monitoring systems. Therefore......, in this paper, the wireless power supply via coupled magnetic resonance (MR-WPS) is proposed for powering the wireless sensor and the associated wireless sensor solution is also proposed. The key specifications of the MR-WPS working in switchgear cabinet with a harsh operation environment are analyzed...... power is able to be delivered to the wireless sensor through the designed MR-WPS, and therefore the theoretical analysis and design is verified....

  11. Kosovo’s Ground Flash Density and Protection of Transmission Lines of the Kosovo Power System from Atmospheric Discharges

    Directory of Open Access Journals (Sweden)

    Bahri Prebreza

    2018-03-01

    Full Text Available In this paper is presented the protection of transmission power lines of the Kosovo Power System from atmospheric discharges, with the use of surge arresters. Atmospheric discharges represent one of the main causes of interruptions for the Kosovo Power System. In addition, the ground flash density for Kosovo is given. The transmission lines with the worst performance regarding atmospheric discharges are discussed in more detail and are presented recommendations about the surge arresters used to protect the system from these overvoltages. The data provided by the localized lightning system in Kosovo enable us to provide a detailed correlation of the reported outages of the Kosovo Power System and corresponding atmospheric discharges. Recommendations for protection in terms of surge arresters are given followed by subsequent dynamic simulations using MATLAB software.

  12. Sustainable Buildings. Using Active Solar Power

    Energy Technology Data Exchange (ETDEWEB)

    Sharp, M. Keith [Univ. of Louisville, KY (United States); Barnett, Russell [Univ. of Louisville, KY (United States)

    2015-04-20

    The objective of this project is to promote awareness and knowledge of active solar energy technologies by installing and monitoring the following demonstration systems in Kentucky: 1) Pool heating system, Churchill Park School, 2) Water heating and daylighting systems, Middletown and Aiken Road Elementary Schools, 3) Photovoltaic street light comparison, Louisville Metro, 4) up to 25 domestic water heating systems across Kentucky. These tasks will be supported by outreach activities, including a solar energy installer training workshop and a Kentucky Solar Energy Conference.

  13. Engineering Lipases: walking the fine line between activity and stability

    Science.gov (United States)

    Dasetty, Siva; Blenner, Mark A.; Sarupria, Sapna

    2017-11-01

    Lipases are enzymes that hydrolyze lipids and have several industrial applications. There is a tremendous effort in engineering the activity, specificity and stability of lipases to render them functional in a variety of environmental conditions. In this review, we discuss the recent experimental and simulation studies focused on engineering lipases. Experimentally, mutagenesis studies have demonstrated that the activity, stability, and specificity of lipases can be modulated by mutations. It has been particularly challenging however, to elucidate the underlying mechanisms through which these mutations affect the lipase properties. We summarize results from experiments and molecular simulations highlighting the emerging picture to this end. We end the review with suggestions for future research which underscores the delicate balance of various facets in the lipase that affect their activity and stability necessitating the consideration of the enzyme as a network of interactions.

  14. LTPS-TFT Pixel Circuit Compensating for TFT Threshold Voltage Shift and IR-Drop on the Power Line for AMOLED Displays

    Directory of Open Access Journals (Sweden)

    Ching-Lin Fan

    2012-01-01

    Full Text Available We propose a new pixel design for the active matrix organic light-emitting diode (AMOLED using low-temperature polycrystalline silicon thin-film transistors (LTPS-TFTs. The proposed pixel is composed of four switching TFTs, one driving TFT (DTFT, and one capacitor. The simulation results are performed by AIM-SPICE software. The error rate of OLED output current with (threshold voltage variation (0.3 V and power line drop by 1 V are improved to about 1.67% and 15%, respectively. Thus, the proposed pixel circuit can successfully overcome drawbacks suffered from DTFT threshold voltage deviation and IR-drop on power line.

  15. Analysis and control of a shunt active power filter

    Energy Technology Data Exchange (ETDEWEB)

    Ottersten, R.; Petersson, Andreas [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1999-09-01

    This report deals with active power filtering of low-frequency current harmonics. The active filter consists of a forced-commutated voltage source inverter with a digital control system. The aim of this master thesis is to investigate the performance of a shunt active power filter, and the parameters influence on the system performance. Three different harmonic identification methods are presented and compared. The shunt active power filter is very well suited for harmonic current reduction, provided that the phase shift due to the digital implementation of the control system is compensated. The performance of the active power filter depends on the switching frequency. When using individual harmonic detection methods the amount of compensation can be fully controlled for each current harmonic.

  16. Sierra Pacific Power Company Alturas Transmission Line Project, Final Environmental Impact Report/Environmental Impact Statement. Volume 3: Appendices

    International Nuclear Information System (INIS)

    1995-11-01

    Sierra Pacific Power Company has proposed the construction and operation of a 345,000 volt overhead electric power transmission line from Alturas, California to Reno, Nevada. This Environmental Impact Report/Environmental Impact Statement will assess the potential environmental impacts of the proposed project and alternatives. This report contains Appendices A--I which contain the following: glossary/abbreviations; scoping report; structure coordinate summary; air quality; biological resources; geology; noise; visual contrast rating forms; and cultural resources

  17. Nuclear power company activity based costing management analysis

    International Nuclear Information System (INIS)

    Xu Dan

    2012-01-01

    With Nuclear Energy Industry development, Nuclear Power Company has the continual promoting stress of inner management to the sustainable marketing operation development. In view of this, it is very imminence that Nuclear Power Company should promote the cost management levels and built the nuclear safety based lower cost competitive advantage. Activity based costing management (ABCM) transfer the cost management emphases from the 'product' to the 'activity' using the value chain analysis methods, cost driver analysis methods and so on. According to the analysis of the detail activities and the value chains, cancel the unnecessary activity, low down the resource consuming of the necessary activity, and manage the cost from the source, achieve the purpose of reducing cost, boosting efficiency and realizing the management value. It gets the conclusion from the detail analysis with the nuclear power company procedure and activity, and also with the selection to 'pieces analysis' of the important cost related project in the nuclear power company. The conclusion is that the activities of the nuclear power company has the obviously performance. It can use the management of ABC method. And with the management of the procedure and activity, it is helpful to realize the nuclear safety based low cost competitive advantage in the nuclear power company. (author)

  18. Antibacterial and anti-breast cancer cell line activities of ...

    African Journals Online (AJOL)

    against acrolein toxicity in vitro, and against stroke in a mouse model [13]. Chang et al. [14] and Ayala-Zavala et al. [6] found that extracts from P. merrillii, P. gilvus, P. rimosus and P. badius have antioxidant activity. Moreover, the extracts from P. gilvus, P. rimosus and P. badius could inhibit growth of the fungus Alternaria.

  19. The Impact of Noise Models on Capacity Performance of Distribution Broadband over Power Lines Networks

    Directory of Open Access Journals (Sweden)

    Athanasios G. Lazaropoulos

    2016-01-01

    Full Text Available This paper considers broadband potential of distribution Broadband over Power Lines (BPL networks when different well-known noise models of the BPL literature are applied. The contribution of this paper is twofold. First, the seven most representative and used noise models of the BPL literature are synopsized in this paper. With reference to this set, the broadband performance of a great number of distribution BPL topologies either Overhead (OV or Underground (UN, either Medium-Voltage (MV or Low-Voltage (LV, is investigated in terms of suitable capacity metrics. Second, based on the proposed capacity metrics, a comparative capacity analysis is performed among various well-validated noise models. Through the careful study of its results, it is demonstrated that during capacity computations of distribution BPL networks, the flat Additive White Gaussian Noise (FL noise model can be comfortably assumed as an efficient noise model either in 3–30 MHz or in 3–88 MHz frequency range since its capacity differences with the other well-proven noise models are negligible.

  20. Line-Interactive Transformerless Uninterruptible Power Supply (UPS with a Fuel Cell as the Primary Source

    Directory of Open Access Journals (Sweden)

    Muhammad Iftikhar

    2018-03-01

    Full Text Available This paper presents line-interactive transformerless Uninterruptible Power Supply (UPS with a fuel cell as the prime energy source. The proposed UPS consists of three major parts (i.e., an output inverter, a unidirectional DC–DC converter, and a battery charger/discharger. Non-isolated topologies of both the unidirectional converter and battery charger/discharger ensure transformerless operation of the UPS system. A new topology of high gain converter is employed for boosting the low voltage of the fuel cell to a higher DC link voltage, with minimum semiconductor count, and high efficiency. A high-gain battery charger/discharger realizes the bidirectional operation between the DC link and the battery bank. Besides, it regulates the DC link voltage during the cold start of fuel cells and keeps the battery bank voltage to only 24 V. A new inverter control scheme is introduced that regulates the output voltage and minimizes the total harmonic distortion for non-linear loading condition. The proposed control scheme integrates proportional-resonant control with slide mode control, which improves the controller’s performance in transient conditions. The proposed UPS system is validated by developing a 1-kVA experimental prototype.

  1. A Fixed-Lag Kalman Smoother to Filter Power Line Interference in Electrocardiogram Recordings.

    Science.gov (United States)

    Warmerdam, G J J; Vullings, R; Schmitt, L; Van Laar, J O E H; Bergmans, J W M

    2017-08-01

    Filtering power line interference (PLI) from electrocardiogram (ECG) recordings can lead to significant distortions of the ECG and mask clinically relevant features in ECG waveform morphology. The objective of this study is to filter PLI from ECG recordings with minimal distortion of the ECG waveform. In this paper, we propose a fixed-lag Kalman smoother with adaptive noise estimation. The performance of this Kalman smoother in filtering PLI is compared to that of a fixed-bandwidth notch filter and several adaptive PLI filters that have been proposed in the literature. To evaluate the performance, we corrupted clean neonatal ECG recordings with various simulated PLI. Furthermore, examples are shown of filtering real PLI from an adult and a fetal ECG recording. The fixed-lag Kalman smoother outperforms other PLI filters in terms of step response settling time (improvements that range from 0.1 to 1 s) and signal-to-noise ratio (improvements that range from 17 to 23 dB). Our fixed-lag Kalman smoother can be used for semi real-time applications with a limited delay of 0.4 s. The fixed-lag Kalman smoother presented in this study outperforms other methods for filtering PLI and leads to minimal distortion of the ECG waveform.

  2. High power test of RF window and coaxial line in vacuum

    International Nuclear Information System (INIS)

    Sun, D.; Champion, M.; Gormley, M.; Kerns, Q.; Koepke, K.; Moretti, A.

    1993-01-01

    Primary rf input couplers for the superconducting accelerating cavities of the TESLA electron linear accelerator test to be performed at DESY, Hamburg, Germany are under development at both DESY and Fermilab. The input couplers consist of a WR650 waveguide to coaxial line transition with an integral ceramic window, a coaxial connection to the superconducting accelerating cavity with a second ceramic window located at the liquid nitrogen heat intercept location, and bellows on both sides of the cold window to allow for cavity motion during cooldown, coupling adjustments and easier assembly. To permit in situ high peak power processing of the TESLA superconducting accelerating cavities, the input couplers are designed to transmit nominally 1 ms long, 2 MW peak, 1.3 GHz rf pulses from the WR650 waveguide at room temperature to the cavities at 1.8 K. The coaxial part of the Fermilab TESLA input coupler design has been tested up to 1.7 MW using the prototype 805 MHz rf source located at the A0 service building of the Tevatron. The rf source, the testing system and the test results are described

  3. Electrocution of Raptors on Power Lines: A Review of Necropsy Methods and Findings.

    Science.gov (United States)

    Kagan, R A

    2016-09-01

    Decades after the problem was first identified, power line electrocution continues to be a cause of avian mortality. Currently, several federal laws protect eagles and other migratory birds, meaning that utility companies may be liable for electrocution-related deaths. Veterinarians and veterinary pathologists called upon to diagnose and treat electrocuted birds should keep this in mind when conducting clinical and postmortem examinations. This review details necropsy findings and methods used to diagnose electrocution. A combination of gross, subgross, and radiographic examinations can aid in identification of subtle injury. Diagnosis is made based on the presence of skin and/or feather burns. Other necropsy findings may include skin lacerations, subcutaneous burns, bruising, limb avulsion, hemopericardium, and vascular rupture. At the US Fish and Wildlife Service's National Forensics Laboratory, from 2000 to 2015, 417 raptor deaths were determined to have been caused by electrocution. Bald eagles and golden eagles were the most commonly submitted species. In a retrospective review of 377 cases, for which whole bodies were submitted, 18% of the electrocuted birds had only a single, small (less than 3 cm in diameter) external burn. Small, isolated burns tended to occur on the undersides of the wings at and distal to the elbow and on the lower legs and feet. These areas should be most carefully examined in cases where electrocution injury is not immediately apparent. © The Author(s) 2016.

  4. Back End of Line Nanorelays for Ultra-low Power Monolithic Integrated NEMS-CMOS Circuits

    KAUST Repository

    Lechuga Aranda, Jesus Javier

    2016-05-01

    Since the introduction of Complementary-Metal-Oxide-Semiconductor (CMOS) technology, the chip industry has enjoyed many benefits of transistor feature size scaling, including higher speed and device density and improved energy efficiency. However, in the recent years, the IC designers have encountered a few roadblocks, namely reaching the physical limits of scaling and also increased device leakage which has resulted in a slow-down of supply voltage and power density scaling. Therefore, there has been an extensive hunt for alternative circuit architectures and switching devices that can alleviate or eliminate the current crisis in the semiconductor industry. The Nano-Electro-Mechanical (NEM) relay is a promising alternative switch that offers zero leakage and abrupt turn-on behaviour. Even though these devices are intrinsically slower than CMOS transistors, new circuit design techniques tailored for the electromechanical properties of such devices can be leveraged to design medium performance, ultra-low power integrated circuits. In this thesis, we deal with a new generation of such devices that is built in the back end of line (BEOL) CMOS process and is an ideal option for full integration with current CMOS transistor technology. Simulation and verification at the circuit and system level is a critical step in the design flow of microelectronic circuits, and this is especially important for new technologies that lack the standard design infrastructure and well-known verification platforms. Although most of the physical and electrical properties of NEM structures can be simulated using standard electronic automation software, there is no report of a reliable behavioural model for NEMS switches that enable large circuit simulations. In this work, we present an optimised model of a BEOL nano relay that encompasses all the electromechanical characteristics of the device and is robust and lightweight enough for VLSI applications that require simulation of thousands of

  5. Qualification of the on-line power determination of fuel elements in irradiation devices in the BR2 reactor

    International Nuclear Information System (INIS)

    Vermeeren, L.; Dekeyser, J.; Gouat, P.; Kalcheva, S.; Koonen, E.; Kuzminov, V.; Verwimp, A.; Weber, M.

    2005-01-01

    Fuel irradiation tests require an on-line monitoring of the fuel power. In the BR2 reactor, this is performed by continuously measuring the enthalpy change in the coolant of the irradiation device and complementing this information with data on power losses, heating of structure parts and spatial power profiles from mock-up test experiments and from calculations. Since a few years Monte Carlo codes (MCNP) are used, describing the BR2 core in great detail for every reactor cycle with its specific core load, yielding not only reliable relative values, but also calculated absolute local power values in agreement with data from PIE analyses. Several methods were conceived to combine the experimental and calculated data for the on-line calculation of the local linear power in the fuel elements; their internal consistency and the consistency with gamma spectroscopy data and data from radiochemical fission product analysis was checked. The data show that fuel irradiations in BR2 can be performed in a well-controlled way, with an accurate and reliable on-line follow-up of the fuel power. (author)

  6. Nuclear power plants - active environment protection|

    International Nuclear Information System (INIS)

    Aegerter, I.

    1987-01-01

    The Federal Commission, which is studying energy scenarios, will doubtlessly come to the conclusion that a withdrawal from nuclear energy is technically and economically feasible. Feasibility alone however is no justification for action. Have the questions been asked correctly by the parliamentarians? Are the real problems being bypassed? Is the demand for a withdrawal from nuclear energy soundly based? Is it not oversimplified? Many people are afraid of nuclear energy because they do not understand it. It is necessary that specialists formulate their ideas so that the layman can easily understand them. The broad public can be educated to lose their fear of nuclear power plants which they compare with the nuclear bombs. They can also be educated to lose their fear of radioactivity. The public should also realize that the CO 2 problem is actual and very serious, and that nuclear energy can in fact help to alleviate this particular problem. 7 refs., 2 figs., 1 tab

  7. Simulation and Hardware Implementation of Shunt Active Power Filter Based on Synchronous Reference Frame Theory

    Directory of Open Access Journals (Sweden)

    Karthikrjan Senthilnathan

    2018-02-01

    Full Text Available This paper describes about the Hybrid Shunt Active Power Filter (HSAPF for the elimination of the current harmonics in the line side of the three phase three wire systems. The Active Power Filter is based on the Voltage Source Converter (VSC topology. The control strategy for the converter is based on Synchronous Reference Frame (SRF theory. The compensation of harmonics is done by the APF which is connected in the shunt configuration to the system. The Shunt APF has the better compensation of current harmonics. The design and implementation of Shunt active power filter is done by MATLAB/Simulink. The real time implementation by using the ATMEGA 8 Microcontroller. The Simulation and Hardware results shows that the current harmonics are eliminated in the system

  8. The active filter voltage ripple correction system of the Brookhaven AGS main magnet power supply

    International Nuclear Information System (INIS)

    Marneris, I.; Bonati, R.; Geller, J.; Sandberg, J.N.; Soukas, A.

    1995-01-01

    This paper, and a companion paper, describe the improvements to the Main Magnet Power Supply (MMPS) so that it enables a more flexible operation of the AGS, enhances its reliability, and also improves the MMPS's ultimate performance specifications. One of the major areas for the latter is the fixed target program operating off the AGS slow extracted beam lines. The active filter, by improving the MMPS output ripple, is instrumental in the improvement of the ultimate duty factor of the extraction beam spill

  9. Distributed Power Flow Controller

    NARCIS (Netherlands)

    Yuan, Z.

    2010-01-01

    In modern power systems, there is a great demand to control the power flow actively. Power flow controlling devices (PFCDs) are required for such purpose, because the power flow over the lines is the nature result of the impedance of each line. Due to the control capabilities of different types of

  10. Small Spacecraft Integrated Power System with Active Thermal Control

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop an integrated power generation and energy storage system with an active thermal management system. Carbon fiber solar panels will contain...

  11. To Solution of Classical Problem Pertaining to Magnetic Interference of Overhead Power Transmission Line on Extended Conducting Communications

    Directory of Open Access Journals (Sweden)

    V. I. Glushko

    2013-01-01

    Full Text Available The paper considers a problem pertaining to magnetic interference of overhead power transmission lines and high-voltage bus bars of electrical installations on extended conducting communications and secondary circuits of relay protection and automation. A simplified task solution has been obtained on the basis of the Carson integral approximation.

  12. ESP On-line Activities: Theory and Practice

    Directory of Open Access Journals (Sweden)

    Hélvia Pereira Pinto Bastos

    2011-07-01

    Full Text Available Reading electronic texts in a foreign language has become an important skill in most professional areas. Electronic literacy is a pedagogical activity which develops both the learner’s linguistic knowledge and his / her ability to communicate and do research on the Internet. This article shows the reasons and how this practice, based on sociocognitive principles and using reading guidelines given by the teaching of Languages for Specific Purposes, has been implemented in the English language programs at CEFET-Campos, RJ. Comments on different aspects of the experience are also provided.

  13. Simulation of Standby Efficiency Improvement for a Line Level Control Resonant Converter Based on Solar Power Systems

    Directory of Open Access Journals (Sweden)

    Ming-Tse Kuo

    2015-01-01

    Full Text Available This paper proposes a new scheme to improve the standby efficiency of the high-power half-bridge line level control (LLC resonant converter. This new circuit is applicable to improving the efficiency of the renewable energy generation system in distributed power systems. The main purpose is to achieve high-efficiency solar and wind power and stable output under different load conditions. In comparison with the traditional one, this novel method can improve standby efficiency at standby. The system characteristics of this proposed method have been analyzed through detailed simulations, which prove its feasibility.

  14. Evaluation on the model of performance predictions for on-line monitoring system for combined-cycle power plant

    International Nuclear Information System (INIS)

    Kim, Si Moon

    2002-01-01

    This paper presents the simulation model developed to predict design and off-design performance of an actual combined cycle power plant(S-Station in Korea), which would be running combined with on-line performance monitoring system in an on-line real-time fashion. The first step in thermal performance analysis is to build an accurate performance model of the power plant, in order to achieve this goal, GateCycle program has been employed in developing the model. This developed models predict design and off-design performance with a precision of one percent over a wide range of operating conditions so that on-line real-time performance monitoring can accurately establish both current performance and expected performance and also help the operator identify problems before they would be noticed

  15. Three phase active power filter with selective harmonics elimination

    Directory of Open Access Journals (Sweden)

    Sozański Krzysztof

    2016-03-01

    Full Text Available This paper describes a three phase shunt active power filter with selective harmonics elimination. The control algorithm is based on a digital filter bank. The moving Discrete Fourier Transformation is used as an analysis filter bank. The correctness of the algorithm has been verified by simulation and experimental research. The paper includes exemplary results of current waveforms and their spectra from a three phase active power filter.

  16. Requirements Specication for Ampliers and Power Supplies in Active Loudspeakers

    DEFF Research Database (Denmark)

    Schneider, Henrik; Jensen, Lasse Crone; Petersen, Lars Press

    2014-01-01

    This work aims to provide designers with a method to develop a requirements specication for power supplies and ampliers in active loudspeakers. The motivation is to avoid over-sizing and unnecessary cost. A realistic estimation of the power supplied during playback of audio in a given loudspeaker...... is obtained by considering a wide range of audio source material, loudness normalization of the source material, crossover ltering, driver characteristics as well as a perceived maximum loudness/volume level. The results from analysing a sub-woofer and a woofer reveals the peak power, peak voltage, peak...... current and apparent power - thus providing a solid foundation for a requirement specication....

  17. New activities in nuclear power plants maintenance

    International Nuclear Information System (INIS)

    Mico, F.; Specht, J.

    2006-01-01

    This article addresses the consequences of the progressive deregulation of the electricity market of several key countries on the maintenance practices and techniques face to the growing pressures on O and M costs. The responses of the nuclear maintenance industry to make maintenance activities more efficient maintaining if not enhancing the safety of NPP's are briefly described. The article also analyses the potential impact of shortage of experience maintenance personnel to serve the NPP's in the future as some countries are already experiencing. (Author)

  18. Shunt Active-Power-Filter Topology Based on Parallel Interleaved Inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Asiminoaei, Lucian; Aeloiza, E.

    2008-01-01

    In this paper, an interleaved active-power-filter concept with reduced size of passive components is discussed. The topology is composed of two pulsewidth-modulation interleaved voltage-source inverters connected together on the ac line and sharing the same dc-link capacitor. The advantages......, because the power sharing allows one to use a higher switching frequency in each inverter. This paper analyzes the design of the passive components and gives a practical and low-cost solution for the minimization of the circulation currents between the inverters, by using common-mode coils. Several...

  19. Qinshan phase II extension nuclear power project thermal stratification and fatigue stress analysis for pressurizer surge line

    International Nuclear Information System (INIS)

    Yu Xiaofei; Zhang Yixiong; Ai Honglei

    2010-01-01

    Thermal stratification of pressurizer surge line induced by the inside fluid brings on global bending moments, local thermal stresses, unexpected displacements and support loadings of the pipe system. In order to avoid a costly three-dimensional computation, a combined 1D/2D technique has been developed and implemented to analyze the thermal stratification and fatigue stress of pressurize surge line of QINSHAN Phase II Extension Nuclear Power Project in this paper, using the computer codes SYSTUS and ROCOCO. According to the mechanical analysis results of stratification, the maximum stress and cumulative usage factor, the loadings at connections of surge line to main pipe and RCP and the displacements of surge line at supports are obtained. (authors)

  20. Technical-parameter calculation model for underground low-power electrical lines and indoor installations used in telecommunications

    Directory of Open Access Journals (Sweden)

    Henry Bastidas Mora

    2011-09-01

    Full Text Available This article presents an analysis of electrical distribution theory for 60Hz-lines operating at low voltage, particularly underground lines and residential indoor installations. Such distribution lines’ behaviour is observed as a function of frequency to consider any advantages regarding the potential use of power transmission lines (PTL for transmitting telecommunication signals. A method for computing the secondary parameters is proposed which has been based on the primary parameters, namely inductance, capacitance, conductance and resistance. The secondary parameters so obtained were characteristic impedance, propagation constant (together with its real value and the attenuation constant. Conductor configurations, insulation materials and gauges commonly used in Colombia were verified for such low-voltage lines. A mathematical model is proposed as a theoretical tool for analysing and predicting characteristic impedance pattern and the attenuations which occur at high frequencies, thereby complementing our group’s previous work. Conclusions are drawn, together with a perspective regarding future work and applications.

  1. Pipe type poles in transmission power lines; Postes tipo tubo en lineas de transmision

    Energy Technology Data Exchange (ETDEWEB)

    Cervantes E, Mario; Becerril A, Armando [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    The first supports for transmission power lines were relatively small structures, of simple configuration, to save reduced clearances to resist load in accordance with its need; with the technical development, gradually appeared higher and higher electric tensions and greater obstacles to overcome, consequently the design of the supports had to be adapted to the new conditions. This gave rise to the development of a specific technique that would adequate and incorporate the continuous engineering advances. In this document the initial considerations on the design poles pipe type are examined; within these considerations mention is made of: the design, the manufacture, the prototype tests, installation, quality control and foundations. The type tube pole is portrayed, as well as the steel reinforcement, finally the types of precast foundations are shown [Espanol] Los primeros soportes para lineas de transmision fueron estructuras relativamente pequenas, de configuracion simple, para salvar claros reducidos y resistir cargas proporcionales a sus necesidades, con el desarrollo de la tecnica, fueron apareciendo tensiones electricas cada vez mas elevadas y obstaculos mayores que vencer, por lo que el diseno de los soportes tuvo que adaptarse a las nuevas condiciones. Esto dio origen al desenvolvimiento de una tecnica especifica que fuese adecuando e incorporando los continuos avances de la ingenieria. En este documento se tratan las consideraciones iniciales del diseno de los postes tipo tubo; dentro de estas consideraciones se citan: el diseno, la fabricacion, las pruebas de prototipo, montajes, control de calidad y cimentaciones. Se ilustra el poste tipo tubo, al igual que el armado del poste, por ultimo se muestra los tipos de cimentaciones precoladas

  2. High Power Combiner/Divider with Coupled Lines for Broadband Applications

    Science.gov (United States)

    2017-03-20

    novel isolation structure will also be presented. I. INTRODUCTION Power divider/combiners are traditionally used in the development of high power ...a novel Gysel divider/combiner structure have been demonstrated. The divider/combiner are applicable to various high- power , broadband radar, EW...Gysel Power Divider With Arbitrary Power Ratios and Filtering Responses Using Coupling Structure ,” IEEE Transactions on Microwave Theory and Tech., vol

  3. Experimental study on using a high-temperature superconducting inductor for power loss reduction in an active power filter

    International Nuclear Information System (INIS)

    Chao, C; To, H P; Grantham, C; Rahman, M F

    2006-01-01

    An active power filter improves the electric power quality through the compensation of harmonics in the power network. A current-source active power filter using a conventional copper inductor for its energy storage has a significant power loss. The loss in the copper inductor can be substantially reduced by using a high-temperature superconducting (HTS) inductor instead. Experiments have been conducted on a prototype current-source active power filter for studying the power loss reduction effect and harmonics compensation performance of the active power filter using a HTS inductor. Experimental results are analysed and discussed in this paper

  4. Design and control of hybrid active power filters

    CERN Document Server

    Lam, Chi-Seng

    2014-01-01

    Design and Control of Hybrid Active Power Filters presents an overview of the current quality problems and their compensators. To get a balance between the system cost and performance, hybrid active power filters (HAPFs) are valuable. The book presents the coverage of resonance phenomena prevention capability, filtering performance and system robustness analysis of HAPF; nonlinear inverter current slope characteristics and their linear operation region requirement analysis of the hysteresis PWM for the HAPF; minimum inverter capacity design procedure of HAPF, adaptive dc-link voltage controller for the HAPF and the real design example of a 220V 10kVA HAPF, in which the system performance analysis method, minimum dc voltage deduction concept and adaptive dc voltage idea can be further extended into the other active compensators, such as APF, static synchronous compensator STATCOM, etc. This book will benefit researchers, graduate students, and electrical power engineers in the field of power-quality compensati...

  5. Terawatt power division and combination using self-magnetically insulated transmission lines

    International Nuclear Information System (INIS)

    Crow, J.T.; Peterson, G.D.

    1980-01-01

    Self-magnetically insulated transmission lines are necessary for the efficient transport of the terawatt pulses used in electron and ion accelerators. For some applications it is desirable to divide one transmission line into two, or to combine outputs of two or more lines into one, by means of self-magnetically insulated convolutes. Tests have been made on a coaxial-to-triaxial convolute in which connections between negative inner and outer lines are made by pins passing through holes in the intermediate positive conductor. Measurements in the 2 MV, 400 kA, 40 ns pulse Mite facility indicate virtually 100% current transport through the convolute and the ability to vary the division of current between the inner and outer lines of the triax by choice of inner line impedance. These measurements, and results obtained with this convolute connected to the ion diode for which it was designed, will be presented

  6. A simple approach to calculate active power of electrosurgical units

    Directory of Open Access Journals (Sweden)

    André Luiz Regis Monteiro

    Full Text Available Abstract Introduction: Despite of more than a hundred years of electrosurgery, only a few electrosurgical equipment manufacturers have developed methods to regulate the active power delivered to the patient, usually around an arbitrary setpoint. In fact, no manufacturer has a method to measure the active power actually delivered to the load. Measuring the delivered power and computing it fast enough so as to avoid injury to the organic tissue is challenging. If voltage and current signals can be sampled in time and discretized in the frequency domain, a simple and very fast multiplication process can be used to determine the active power. Methods This paper presents an approach for measuring active power at the output power stage of electrosurgical units with mathematical shortcuts based on a simple multiplication procedure of discretized variables – frequency domain vectors – obtained through Discrete Fourier Transform (DFT applied on time-sampled voltage and current vectors. Results Comparative results between simulations and a practical experiment are presented – all being in accordance with the requirements of the applicable industry standards. Conclusion An analysis is presented comparing the active power analytically obtained through well-known voltage and current signals against a computational methodology based on vector manipulation using DFT only for time-to-frequency domain transformation. The greatest advantage of this method is to determine the active power of noisy and phased out signals with neither complex DFT or ordinary transform methodologies nor sophisticated computing techniques such as convolution. All results presented errors substantially lower than the thresholds defined by the applicable standards.

  7. Single-Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications

    Energy Technology Data Exchange (ETDEWEB)

    Chinthavali, Madhu Sudhan [ORNL; Onar, Omer C [ORNL; Miller, John M [ORNL; Tang, Lixin [ORNL

    2013-01-01

    Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance. To understand the power flow through the system this paper presents a novel approach to the system model and the impact of different control parameters on the load power. The implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation is also discussed.

  8. DSP control of photovoltaic power generation system adding the function of shunt active power filter

    Energy Technology Data Exchange (ETDEWEB)

    Seo, H.-R.; Kim, K.-H.; Park, Y.-G.; Park, M.; Yu, I.-K. [Changwon National Univ., SarimDong (Korea, Republic of). Dept. of Electrical Engineering

    2007-07-01

    The growing number of power electronics-based equipment has created a problem on the quality of electric power supply since both high power industrial loads and domestic loads cause harmonics in the network voltage. Power quality problems can occur in the system or can be caused by the consumer. Active filter (AF) is widely used to compensate current harmonics and/or current imbalance of harmonic-producing loads. The power output of a photovoltaic (PV) system is directly affected by weather conditions. When alternating current (AC) power supply is required, power conversion by an inverter and an MPPT control is necessary. The proliferation of nonlinear loads such as inverter of PV power generation system can be treated as a harmonic source for the power distribution system. As such, the PV system combined with the function of the active filter system can be useful for the application in power distribution systems. This paper described a PV-AF system using DSP to prove that it is possible to combine AF theory to the three phase PV system connected to utility and verify it through experimental results. The paper described the control method of the PV-AF system, with reference to the photovoltaic power generation system, shunt active filter and PV-AF system. The experimental set-up was also presented. A laboratory system was designed and constructed to confirm the viability of the proposed PV-AF system. The test results revealed the stability and effectiveness of the proposed PV-AF system. 12 refs., 1 tabs., 12 figs.

  9. Retrotransposon long interspersed nucleotide element-1 (LINE-1) is activated during salamander limb regeneration

    Science.gov (United States)

    Zhu, Wei; Kuo, Dwight; Nathanson, Jason; Satoh, Akira; Pao, Gerald M.; Yeo, Gene W.; Bryant, Susan V.; Voss, S. Randal; Gardiner, David M.; Hunter, Tony

    2012-01-01

    Salamanders possess an extraordinary capacity for tissue and organ regeneration when compared to mammals. In our effort to characterize the unique transcriptional fingerprint emerging during the early phase of salamander limb regeneration, we identified transcriptional activation of some germline-specific genes within the Mexican axolotl (Ambystoma mexicanum) that is indicative of cellular reprogramming of differentiated cells into a germline-like state. In this work, we focus on one of these genes, the long interspersed nucleotide element-1 (LINE-1) retrotransposon, which is usually active in germ cells and silent in most of the somatic tissues in other organisms. LINE-1 was found to be dramatically upregulated during regeneration. In addition, higher genomic LINE-1 content was also detected in the limb regenerate when compared to that before amputation indicating that LINE-1 retrotransposition is indeed active during regeneration. Active LINE-1 retrotransposition has been suggested to have a potentially deleterious impact on genomic integrity. Silencing of activated LINE-1 by small RNAs has been reported to be part of the machinery aiming to maintain genomic integrity. Indeed, we were able to identify putative LINE-1-related piRNAs in the limb blastema. Transposable element-related piRNAs have been identified frequently in the germline in other organisms. Thus, we present here a scenario in which a unique germline-like state is established during axolotl limb regeneration, and the re-activation of LINE-1 may serve as a marker for cellular dedifferentiation in the early-stage of limb regeneration. PMID:22913491

  10. A Possibilistic Approach for the Prediction of the Risk of Interference between Power and Signal Lines Onboard Satellites

    Directory of Open Access Journals (Sweden)

    Nicola Toscani

    2018-01-01

    Full Text Available This work presents a hybrid random/fuzzy approach for uncertainty quantification in electromagnetic modelling, which combines probability and possibility theory in order to properly account for both aleatory and epistemic uncertainty, respectively. In particular, a typical intrasystem electromagnetic-compatibility problem in aerospace applications is considered, where some parameters are affected by fabrication tolerances or other kinds of randomness (aleatory uncertainty and others are inherently deterministic but unknown due to human’s lack of knowledge (epistemic uncertainty. Namely, a differential-signal line in a satellite is subject to crosstalk due to a nearby dc power line carrying conducted emissions generated by a dc-dc converter in a wide frequency range (up to 100 MHz. The nonideal features of the signal line (e.g., weak unbalance of terminal loads are treated as random variables (RVs, whereas the mutual position of signal and power line is characterized by possibility theory through suitable fuzzy variables. Such a hybrid approach allows deriving a general and exhaustive description of uncertainty of the target variable of interest, that is, the differential noise voltage induced in the signal line. The obtained results are compared versus a conventional Monte Carlo simulation where all parameters are treated as RVs, and the advantages of the proposed approach (in terms of completeness and richness of information gained about sensitivity of results are highlighted.

  11. Power line emission 50/60 Hz and Schumann resonances observed by microsatellite Chibis-M in the Earth's ionosphere

    Science.gov (United States)

    Dudkin, Denys; Pilipenko, Vyacheslav; Dudkin, Fedir; Pronenko, Vira; Klimov, Stanislav

    2015-04-01

    The overhead power lines are the sources of intense wideband electromagnetic (EM) emission, especially in ELF-VLF range, because of significant length (up to a few thousand kilometers) and strong 50/60 Hz currents with noticeable distortion. The radiation efficiency of the power line emission (PLE) increases with the harmonic order, so they are well observed by ground-based EM sensors. However their observations by low orbiting satellites (LEO) are very rare, particularly at basic harmonic 50/60 Hz, because of the ionospheric plasma opacity in ELF band. The Schumann resonance (SR) is the narrow-band EM noise that occurs due to the global thunderstorm activity in the Earth-ionosphere cavity. The first five eigenmodes of the SR are 7.8, 14.3, 20.8, 27.3 and 33.8 Hz and, thus, SR harmonics are also strongly absorbed by the Earth ionosphere. The published numerical simulations show that the penetration depth of such an ELF emission into the Earth's ionosphere is limited to 50-70 km for electric field and 120-240 km for magnetic field. From this follows, that PLE and SR can hardly ever be detected by LEO satellites, i.e. above the F-layer of ionosphere. In spite of this fact, these emissions were recently observed with use of the electric field antennas placed on the satellites C/NOFS (USA) and Chibis-M (Russia). Microsatellite Chibis-M was launched on January 24, 2012, at 23:18:30 UTC from the cargo ship "Progress M-13M" to circular orbit with altitude ~500 km and inclination ~52° . Chibis-M mass is about 40 kg where one third is a scientific instrumentation. The dimensions of the microsatellite case are 0.26x0.26x0.54 m with the outside mounted solar panels, service and scientific instrumentation. The main scientific objective of Chibis-M is the theoretical model verification for the atmospheric gamma-ray bursts. It requires the study of the accompanying EM processes such as the plasma waves produced by the lightning discharges in the VLF band. Chibis-M decayed on 15

  12. On Variable Reverse Power Flow-Part I: Active-Reactive Optimal Power Flow with Reactive Power of Wind Stations

    Directory of Open Access Journals (Sweden)

    Aouss Gabash

    2016-02-01

    Full Text Available It has recently been shown that using battery storage systems (BSSs to provide reactive power provision in a medium-voltage (MV active distribution network (ADN with embedded wind stations (WSs can lead to a huge amount of reverse power to an upstream transmission network (TN. However, unity power factors (PFs of WSs were assumed in those studies to analyze the potential of BSSs. Therefore, in this paper (Part-I, we aim to further explore the pure reactive power potential of WSs (i.e., without BSSs by investigating the issue of variable reverse power flow under different limits on PFs in an electricity market model. The main contributions of this work are summarized as follows: (1 Introducing the reactive power capability of WSs in the optimization model of the active-reactive optimal power flow (A-R-OPF and highlighting the benefits/impacts under different limits on PFs. (2 Investigating the impacts of different agreements for variable reverse power flow on the operation of an ADN under different demand scenarios. (3 Derivation of the function of reactive energy losses in the grid with an equivalent-π circuit and comparing its value with active energy losses. (4 Balancing the energy curtailment of wind generation, active-reactive energy losses in the grid and active-reactive energy import-export by a meter-based method. In Part-II, the potential of the developed model is studied through analyzing an electricity market model and a 41-bus network with different locations of WSs.

  13. Improvement of active filter for HIMAC power sources

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Masayuki [National Inst. of Radiological Sciences, Chiba (Japan); Kubo, Hiroshi; Furuzeki, Shoichiro; Kanazawa, Toru

    1996-03-01

    For the power sources of the synchrotron electromagnets for the heavy particle beam cancer therapy apparatus HIMAC in National Institute of Radiological Science, in order to stabilize the taken-out beam, the ripple property as low as below 1 x 10{sup -6} is required. As for this electromagnet power sources, various devices were applied to lower ripples, and the required specifications have been satisfied. Also the beam spill is stable, but slight variation has been observed, therefore, by improving the performance of the active filter, the ripples were improved. The specifications of the electromagnet power sources and the whole constitution of the power source system are shown. In the HIMAC power sources, the means for having realized the low ripple performance so far are explained. Those are the absorption of the ineffective power generated from the power sources, the control of the ripples of common made due to the transducer thyristor, and the sure compensation of ripples by the control circuit for the power sources. By adding the band pass filters to the active filter, its characteristics were improved. As the result, 1200 Hz ripple component was reduced by 41 db, thus the sufficient effect was obtained. Hereafter, by the high sensitivity measurement of the current of electromagnets and the evaluation of magnetic fields, the validity will be evaluated. (K.I.)

  14. A High Power Density Integrated Charger for Electric Vehicles with Active Ripple Compensation

    Directory of Open Access Journals (Sweden)

    Liwen Pan

    2015-01-01

    Full Text Available This paper suggests a high power density on-board integrated charger with active ripple compensation circuit for electric vehicles. To obtain a high power density and high efficiency, silicon carbide devices are reported to meet the requirement of high-switching-frequency operation. An integrated bidirectional converter is proposed to function as AC/DC battery charger and to transfer energy between battery pack and motor drive of the traction system. In addition, the conventional H-bridge circuit suffers from ripple power pulsating at second-order line frequency, and a scheme of active ripple compensation circuit has been explored to solve this second-order ripple problem, in which a pair of power switches shared traction mode, a ripple energy storage capacitor, and an energy transfer inductor. Simulation results in MATLAB/Simulink validated the eligibility of the proposed topology. The integrated charger can work as a 70 kW motor drive circuit or a converter with an active ripple compensation circuit for 3 kW charging the battery. The impact of the proposed topology and control strategy on the integrated charger power losses, efficiency, power density, and thermal performance has also been analysed and simulated.

  15. Stray current induced corrosion in lightning rod cables of 525 kV power lines towers: a case study

    International Nuclear Information System (INIS)

    Wojcicki, F. R.; Negrisoli, M. E. M.; Franco, C. V.

    2003-01-01

    With the growth of several areas in modern society, the necessity to generate and carry electrical energy to big cities has greatly increased. Cables supported by power towers with galvanized steel foundation usually carry energy. As the foundations are underground they may cause high rates of corrosion. These are usually detected by a conventional potential measurement using a Cu/CuSO 4 reference electrode. It is believed that corrosion results from stray currents that flow through the ground to close the loop between neighboring towers. Stray currents originate in the lightning rod cables of the power line towers, induced by the strong electromagnetic and electric fields of the energized power lines. The intensity and direction of those currents were measured, indicating substantial values of both their AC and DC components. The potential of the tower ground system, measured in the perpendicular direction of the main axis of the power line, was plotted as a function of the distance to the tower base. The results clearly indicated the tendency to corrosive attack in the anodic towers as reflected by the slope of the plot, whereas no signs of corrosion could be found in the reverse slope, confirming the visual inspection of the foundation. The profile of the potential plots could be changed providing the electric insulation of the lightning rod cable. (Author) 8 refs

  16. A Multilayer Perceptron-Based Impulsive Noise Detector with Application to Power-Line-Based Sensor Networks

    KAUST Repository

    Chien, Ying-Ren

    2018-04-10

    For power-line-based sensor networks, impulsive noise (IN) will dramatically degrade the data transmission rate in the power line. In this paper, we present a multilayer perceptron (MLP)-based approach to detect IN in orthogonal frequency-division multiplexing (OFDM)-based baseband power line communications (PLCs). Combining the MLP-based IN detection method with the outlier detection theory allows more accurate identification of the harmful residual IN. For OFDM-based PLC systems, the high peak-to-average power ratio (PAPR) of the received signal makes detection of harmful residual IN more challenging. The detection mechanism works in an iterative receiver that contains a pre-IN mitigation and a post-IN mitigation. The pre-IN mitigation is meant to null the stronger portion of IN, while the post-IN mitigation suppresses the residual portion of IN using an iterative process. Compared with previously reported IN detectors, the simulation results show that our MLP-based IN detector improves the resulting bit error rate (BER) performance.

  17. Avoidance of Pressure Oscillations in Discrete Fluid Power Systems with Transmission Lines - An Analytical Approach

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.

    2014-01-01

    Discrete fluid power technology attracts great attention because it enables energy efficiency and robust system architectures. However, the discrete nature of this technology naturally brings shifting phenomenons into the picture. For fluid power system the relative high inductance of fluid...

  18. Photovoltaic power system tests on an 8-kilowatt single-phase line-commutated inverter

    Science.gov (United States)

    Stover, J. B.

    1978-01-01

    Efficiency and power factor were measured as functions of solar array voltage and current. The effects of input shunt capacitance and series inductance were determined. Tests were conducted from 15 to 75 percent of the 8 kW rated inverter input power. Measured efficiencies ranged from 76 percent to 88 percent at about 50 percent of rated inverter input power. Power factor ranged from 36 percent to 72 percent.

  19. Cytotoxic Activity of Selected Iranian Traditional Medicinal Plants on Colon, Colorectal and Breast Cancer Cell Lines

    Directory of Open Access Journals (Sweden)

    Leila Mohammad Taghizadeh Kashani

    2014-11-01

    Full Text Available Background: Many natural products from plants have been recognized to exert anticancer activity. In this study, ethanolic extracts of selected medicinal herbs from Iranian flora including Alyssum homolocarpum Fisch. (from seeds, Urtica dioica L. (from aerial parts, Cichorium intybus L. (from roots and Solanum nigrum L. (from fruits, were evaluated for their cytotoxic effect on different cell lines.Methods: Cytotoxic effect of these extracts was studied on three different cancer cell lines; colon carcinoma (HT-29, colorectal adenocarcinoma (Caco-2 and breast ductal carcinoma (T47D. In addition, Swiss mouse embryo fibroblasts (NIH 3T3 were used as normal nonmalignant cells. MTT assay (3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide was utilized for calculating the cytotoxicity of extracts on cell lines.Results: Results showed the potent cytotoxic activity of U. dioica ethanolic extract against T47D cell line with IC50 value of 46.14±4.55 µg/ml. Other extracts showed poor activity with IC50>100 µg/ml.Conclusions: Cytotoxic activity recorded in the present study revealed high potential antiproliferative activity of U. dioica ethanolic extract against T47D cell line. The real IC50 values of this extract may be considerably lower than the IC50 measured in our study if its pharmacological active compounds become pure. The results emphasize the importance of studies on U. dioica ethanolic extract to characterize potential components as cytotoxic natural medicines.

  20. Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits

    Directory of Open Access Journals (Sweden)

    Ming-Tse Kuo

    2013-07-01

    Full Text Available Taiwan’s power system is isolated and not supported by other interconnected systems. Consequently, the system frequency immediately reflects changes in the system loads. Pumped storage units are crucial for controlling power frequency. These units provide main or auxiliary capacities, reducing the allocation of frequency-regulating reserve (FRR and further reducing generation costs in system operations. Taiwan’s Longmen Nuclear Power Plant is set to be converted for commercial operations, which will significantly alter the spinning reserves in the power system. Thus, this study proposes a safe and economic pumped storage unit dispatch strategy. This strategy is used to determine the optimal FRR capacity and 1-min recovery frequency in a generator failure occurrence at the Longmen Power Plant. In addition, this study considered transmission capacity constraints and conducted power flow analysis of the power systems in Northern, Central, and Southern Taiwan. The results indicated that, in the event of a failure at Longmen Power Plant, the proposed strategy can not only recover the system frequency to an acceptable range to prevent underfrequency load-shedding, but can also mitigate transmission line overloading.

  1. La Nueva Generación de las Power Line Communications en el Servicio Triple Play

    Directory of Open Access Journals (Sweden)

    Luís Enrique Conde del Oso

    2010-09-01

    Full Text Available Normal 0 21 false false false ES-TRAD X-NONE X-NONE MicrosoftInternetExplorer4 st1:*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Se explica las nuevas características presentes en la Nueva Generación de los sistemas Power Line Communication, así como las actuales posibilidades de los nuevos y novedosos servicios a ofertar con estos sistemas. Otros de los aspectos abordados en el artículo son la experiencia cubana en la implementación de varios diseños de redes con este tipo de tecnología, así como los principales parámetros que deben ser validados en una prueba de aceptación de estos sistemas, con vistas a pasar las rigorosas pruebas que exigen los Órganos Reguladores para garantizar la coexistencia armoniosa de esta novedosa tecnología con otras ya presentes en nuestras Redes de Telecomunicaciones. Finalmente se muestran algunos diseños que facilitan brindar a través de estos sistemas un servicio Triple Play, a los operadores de telecomunicaciones, con orientación al uso de la baja tensión y mas específicamente hacia el interior de las edificaciones, donde el tendido eléctrico es propiedad del dueño del inmueble, permitiendo de esta manera a los Operadores de Telecomunicaciones tener un completo acceso a la Red, facilitándoles una acción inmediata ante

  2. Communication Systems and Study Method for Active Distribution Power systems

    DEFF Research Database (Denmark)

    Wei, Mu; Chen, Zhe

    Due to the involvement and evolvement of communication technologies in contemporary power systems, the applications of modern communication technologies in distribution power system are becoming increasingly important. In this paper, the International Organization for Standardization (ISO......) reference seven-layer model of communication systems, and the main communication technologies and protocols on each corresponding layer are introduced. Some newly developed communication techniques, like Ethernet, are discussed with reference to the possible applications in distributed power system....... The suitability of the communication technology to the distribution power system with active renewable energy based generation units is discussed. Subsequently the typical possible communication systems are studied by simulation. In this paper, a novel method of integrating communication system impact into power...

  3. Device for measuring active, reactive and apparent power

    Energy Technology Data Exchange (ETDEWEB)

    Bartosinski, E.; Wieland, J.

    1982-09-30

    The plan consists of a traditional electrodynamic mechanism for measuring power (IM) supplemented by three switches, two rectifiers, resistor, included in parallel, and phaseshifting throttle included in series with the voltage coil of the IM. This makes it possible by selection to perform three types of measurements: active power of alternating current or power of direct current, only the voltage coils and the IM current are engaged; reactive power, the resistor and the throttle are additionally engaged by the aforementioned method; complete (apparent) power--the current and the voltage are supplied directly to the IM coils, but in contrast to the first case, through rectifiers. The influence of the highest harmonic components of voltage and current which are not significant for industrial measurements can be eliminated in necessary cases using filtering devices.

  4. Active Power Control of Waked Wind Farms: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Paul A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); van Wingerden, Jan-Willem [Delft University of Technology; Pao, Lucy [University of Colorado; Aho, Jacob [University of Colorado

    2017-08-15

    Active power control can be used to balance the total power generated by wind farms with the power consumed on the electricity grid. With the increasing penetration levels of wind energy, there is an increasing need for this ancillary service. In this paper, we show that the tracking of a certain power reference signal provided by the transmission system operator can be significantly improved by using feedback control at the wind farm level. We propose a simple feedback control law that significantly improves the tracking behavior of the total power output of the farm, resulting in higher performance scores. The effectiveness of the proposed feedback controller is demonstrated using high-fidelity computational fluid dynamics simulations of a small wind farm.

  5. Nuclear power development and nuclear data activities in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Gui Ah Auu [Malaysian Institute for Nuclear Technology Research, Ministry of Science, Technology and the Environment, Selangor (Malaysia)

    1999-03-01

    In this paper, research activities on nuclear power requirement carried out jointly by MINT and other organizations are described. Also discussed are activities on neutronics such as TRIGA reactor fuel management, storage pool criticality, and reactor fuel transfer cask calculations. In addition, recent work on radiation transport activities in MINT such as skyshine and photon phantom dose calculations using the MCNP and MRIPP computer codes are presented. Finally, nuclear data measurement works by researchers in Malaysian universities are described. (author)

  6. Nuclear power development and nuclear data activities in Malaysia

    International Nuclear Information System (INIS)

    Gui Ah Auu

    1999-01-01

    In this paper, research activities on nuclear power requirement carried out jointly by MINT and other organizations are described. Also discussed are activities on neutronics such as TRIGA reactor fuel management, storage pool criticality, and reactor fuel transfer cask calculations. In addition, recent work on radiation transport activities in MINT such as skyshine and photon phantom dose calculations using the MCNP and MRIPP computer codes are presented. Finally, nuclear data measurement works by researchers in Malaysian universities are described. (author)

  7. Photovoltaic solar system connected to the electric power grid operating as active power generator and reactive power compensator

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, F.L.; Moraes, A.J.; Guimaraes, G.C.; Sanhueza, S.M.R.; Vaz, A.R. [Federal University of Uberlandia (UFU), MG (Brazil)

    2009-07-01

    In the case of photovoltaic solar systems (PV) acting as a distributed generation (DG), the DC energy obtained is fed through the power-conditioning unit (inverter) to the grid. The majority of contemporary inverters used in DG systems are current source inverters (CSI) operating at unity power factor. If, however, we assume that voltage source inverters (VSI) can be utilized instead of CSI, we can generate reactive power commensurate with the remaining unused capacity at any given point in time. According to the theory of instantaneous power, the reactive and active power of inverter can be regulated by changing the amplitude and the phase of the output voltage of the inverter. Based on this theory, the active power output and the reactive power compensation (RPC) of the system are realized simultaneously. When the insolation is weak or the PV modules are inoperative at night, the RPC feature of PV system can still be used to improve the utilization factor of the inverter. The MATLAB simulation results validate the feasibility of the method. (author)

  8. Fast-wave power flow along SOL field lines in NSTX and the associated power deposition profile across the SOL in front of the antenna

    International Nuclear Information System (INIS)

    Perkins, R.J.; Bell, R.E.; Diallo, A.; Gerhardt, S.; Hosea, J.C.; Jaworski, M.A.; LeBlanc, B.P.; Kramer, G.J.; Maingi, R.; Phillips, C.K.; Podestà, M.; Roquemore, L.; Scotti, F.; Ahn, J.-W.; Gray, T.K.; Green, D.L.; McLean, A.; Ryan, P.M.; Jaeger, E.F.; Sabbagh, S.

    2013-01-01

    Fast-wave heating and current drive efficiencies can be reduced by a number of processes in the vicinity of the antenna and in the scrape-off layer (SOL). On NSTX from around 25% to more than 60% of the high-harmonic fast-wave power can be lost to the SOL regions, and a large part of this lost power flows along SOL magnetic field lines and is deposited in bright spirals on the divertor floor and ceiling. We show that field-line mapping matches the location of heat deposition on the lower divertor, albeit with a portion of the heat outside of the predictions. The field-line mapping can then be used to partially reconstruct the profile of lost fast-wave power at the midplane in front of the antenna, and the losses peak close to the last closed flux surface as well as the antenna. This profile suggests a radial standing-wave pattern formed by fast-wave propagation in the SOL, and this hypothesis will be tested on NSTX-U. RF codes must reproduce these results so that such codes can be used to understand this edge loss and to minimize RF heat deposition and erosion in the divertor region on ITER. (paper)

  9. Constraints on the outer radius of the broad emission line region of active galactic nuclei

    Science.gov (United States)

    Landt, Hermine; Ward, Martin J.; Elvis, Martin; Karovska, Margarita

    2014-03-01

    Here we present observational evidence that the broad emission line region (BELR) of active galactic nuclei (AGN) generally has an outer boundary. This was already clear for sources with an obvious transition between the broad and narrow components of their emission lines. We show that the narrow component of the higher-order Paschen lines is absent in all sources, revealing a broad emission line profile with a broad, flat top. This indicates that the BELR is kinematically separate from the narrow emission line region. We use the virial theorem to estimate the BELR outer radius from the flat top width of the unblended profiles of the strongest Paschen lines, Paα and Paβ, and find that it scales with the ionizing continuum luminosity roughly as expected from photoionization theory. The value of the incident continuum photon flux resulting from this relationship corresponds to that required for dust sublimation. A flat-topped broad emission line profile is produced by both a spherical gas distribution in orbital motion and an accretion disc wind if the ratio between the BELR outer and inner radius is assumed to be less than ˜100-200. On the other hand, a pure Keplerian disc can be largely excluded, since for most orientations and radial extents of the disc the emission line profile is double-horned.

  10. Evidence for extreme divergence of open field lines from solar activity

    International Nuclear Information System (INIS)

    Dulk, G.A.; Suzuki, S.; Melrose, D.B.

    1979-01-01

    This paper reviews the evidence on the structure of the open magnetic field lines that emerge from solar active regions into interplanetary space. The evidence comes mainly from the measured sizes, positions and polarization of Type III and Type V bursts, and from electron streams observed from space. It is found that the observations are best interpreted in terms of a strongly-diverging field topology, with the open field lines filling a cone of angle approx. 60 0

  11. Harmonic Analysis and Active Filtering in Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Freijedo Fernandez, Francisco Daniel; Guerrero, Josep M.

    2015-01-01

    Due to presence of long high voltage cable networks, and power transformers for the grid connection, the offshore wind power plants (OWPPs) are susceptible to harmonic distortion and resonances. The grid connection of OWPP should not cause the harmonic distortion beyond the permissible limits...... at the point of common coupling (PCC). The resonance conditions should be avoided in all cases. This paper describes the harmonic analysis techniques applied on an OWPP network model. A method is proposed to estimate the harmonic current compensation from a shunt-connected active power filter to mitigate...

  12. IAEA activities in nuclear power plant personnel training and qualification

    International Nuclear Information System (INIS)

    Mautner-Markhof, F.

    1993-01-01

    Training to achieve and maintain the qualification and competence of nuclear power personnel is essential for safe and economic nuclear power. Technical Cooperation Meeting on Training-Related Activities for Nuclear Power Plant (NPP) Personnel in the countries of Central and Eastern Europe (CEEC) and of the former Soviet Union (FSU) has as its main objective the identification, through information exchange and discussion, of possible Technical Cooperation (TC) projects to assist Member States in meeting NPP personnel training needs and priorities, including the enhancing of training capabilities

  13. Nuclear power reactor safety research activities in CIAE

    International Nuclear Information System (INIS)

    Pu Shendi; Huang Yucai; Xu Hanming; Zhang Zhongyue

    1994-01-01

    The power reactor safety research activities in CIAE are briefly reviewed. The research work performed in 1980's and 1990's is mainly emphasised, which is closely related to the design, construction and licensing review of Qinshan Nuclear Power Plant and the safety review of Guangdong Nuclear Power Station. Major achievements in the area of thermohydraulics, nuclear fuel, probabilistic safety assessment and severe accident researches are summarized. The foreseeable research plan for the near future, relating to the design and construction of 600 MWe PWR NPP at Qinshan Site (phase II development) is outlined

  14. Microfluidic electrochemical sensor for on-line monitoring of aerosol oxidative activity.

    Science.gov (United States)

    Sameenoi, Yupaporn; Koehler, Kirsten; Shapiro, Jeff; Boonsong, Kanokporn; Sun, Yele; Collett, Jeffrey; Volckens, John; Henry, Charles S

    2012-06-27

    Particulate matter (PM) air pollution has a significant impact on human morbidity and mortality; however, the mechanisms of PM-induced toxicity are poorly defined. A leading hypothesis states that airborne PM induces harm by generating reactive oxygen species in and around human tissues, leading to oxidative stress. We report here a system employing a microfluidic electrochemical sensor coupled directly to a particle-into-liquid sampler (PILS) system to measure aerosol oxidative activity in an on-line format. The oxidative activity measurement is based on the dithiothreitol (DTT) assay, where, after being oxidized by PM, the remaining reduced DTT is analyzed by the microfluidic sensor. The sensor consists of an array of working, reference, and auxiliary electrodes fabricated in a poly(dimethylsiloxane)-based microfluidic device. Cobalt(II) phthalocyanine-modified carbon paste was used as the working electrode material, allowing selective detection of reduced DTT. The electrochemical sensor was validated off-line against the traditional DTT assay using filter samples taken from urban environments and biomass burning events. After off-line characterization, the sensor was coupled to a PILS to enable on-line sampling/analysis of aerosol oxidative activity. Urban dust and industrial incinerator ash samples were aerosolized in an aerosol chamber and analyzed for their oxidative activity. The on-line sensor reported DTT consumption rates (oxidative activity) in good correlation with aerosol concentration (R(2) from 0.86 to 0.97) with a time resolution of approximately 3 min.

  15. Gamma power is phase-locked to posterior alpha activity.

    Directory of Open Access Journals (Sweden)

    Daria Osipova

    Full Text Available Neuronal oscillations in various frequency bands have been reported in numerous studies in both humans and animals. While it is obvious that these oscillations play an important role in cognitive processing, it remains unclear how oscillations in various frequency bands interact. In this study we have investigated phase to power locking in MEG activity of healthy human subjects at rest with their eyes closed. To examine cross-frequency coupling, we have computed coherence between the time course of the power in a given frequency band and the signal itself within every channel. The time-course of the power was calculated using a sliding tapered time window followed by a Fourier transform. Our findings show that high-frequency gamma power (30-70 Hz is phase-locked to alpha oscillations (8-13 Hz in the ongoing MEG signals. The topography of the coupling was similar to the topography of the alpha power and was strongest over occipital areas. Interestingly, gamma activity per se was not evident in the power spectra and only became detectable when studied in relation to the alpha phase. Intracranial data from an epileptic subject confirmed these findings albeit there was slowing in both the alpha and gamma band. A tentative explanation for this phenomenon is that the visual system is inhibited during most of the alpha cycle whereas a burst of gamma activity at a specific alpha phase (e.g. at troughs reflects a window of excitability.

  16. Nuclear techniques for the on-line bulk analysis of carbon in coal-fired power stations.

    Science.gov (United States)

    Sowerby, B D

    2009-09-01

    Carbon trading schemes usually require large emitters of CO(2), such as coal-fired power stations, to monitor, report and be audited on their CO(2) emissions. The emission price provides a significant additional incentive for power stations to improve efficiency. In the present paper, previous work on the bulk determination of carbon in coal is reviewed and assessed. The most favourable method is that based on neutron inelastic scattering. The potential role of on-line carbon analysers in improving boiler efficiency and in carbon accounting is discussed.

  17. Analysis of Two Electrocution Accidents in Greece that Occurred due to Unexpected Re-energization of Power Lines

    Directory of Open Access Journals (Sweden)

    Aikaterini D. Baka

    2014-09-01

    Full Text Available Investigation and analysis of accidents are critical elements of safety management. The over-riding purpose of an organization in carrying out an accident investigation is to prevent similar accidents, as well as seek a general improvement in the management of health and safety. Hundreds of workers have suffered injuries while installing, maintaining, or servicing machinery and equipment due to sudden re-energization of power lines. This study presents and analyzes two electrical accidents (1 fatal injury and 1 serious injury that occurred because the power supply was reconnected inadvertently or by mistake.

  18. Analysis of Two Electrocution Accidents in Greece that Occurred due to Unexpected Re-energization of Power Lines.

    Science.gov (United States)

    Baka, Aikaterini D; Uzunoglu, Nikolaos K

    2014-09-01

    Investigation and analysis of accidents are critical elements of safety management. The over-riding purpose of an organization in carrying out an accident investigation is to prevent similar accidents, as well as seek a general improvement in the management of health and safety. Hundreds of workers have suffered injuries while installing, maintaining, or servicing machinery and equipment due to sudden re-energization of power lines. This study presents and analyzes two electrical accidents (1 fatal injury and 1 serious injury) that occurred because the power supply was reconnected inadvertently or by mistake.

  19. The effect of family therapy on the changes in the severity of on-line game play and brain activity in adolescents with on-line game addiction

    Science.gov (United States)

    Han, Doug Hyun; Kim, Sun Mi; Lee, Young Sik; Renshaw, Perry F.

    2015-01-01

    We evaluated whether a brief 3-week family therapy intervention would change patterns of brain activation in response to affection and gaming cues in adolescents from dysfunctional families who met criteria for on-line game addiction. Fifteen adolescents with on-line game addiction and fifteen adolescents without problematic on-line game play and an intact family structure were recruited. Over 3 weeks, families were asked to carry out homework assignments focused on increasing family cohesion for more than 1 hour/day and 4 days/week. Before therapy, adolescents with on-line game addiction demonstrated decreased activity as measured by functional magnetic resonance imaging (fMRI) within the caudate, middle temporal gyrus, and occipital lobe in response to images depicting parental affection and increased activity of the middle frontal and inferior parietal in response scenes from on-line games, relative to healthy comparison subjects. Improvement in perceived family cohesion following 3 weeks of treatment was associated with an increase in the activity of the caudate nucleus in response to affection stimuli and was inversely correlated with changes in on-line game playing time. With evidence of brain activation changes in response to on-line game playing cues and images depicting parental love, the present findings suggest that family cohesion may be an important factor in the treatment of problematic on-line game playing. PMID:22698763

  20. Development of electric power transmission line anomaly approaching alarm system. Sodensen ijo sekkin keiho sochi no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kusaba, Masaro; Tabata, Takatoshi; Miyazaki, Shusuke [Kyushu Electric Power Co., Inc., Fukuoka (Japan)

    1989-03-30

    In order to plan preventive measures from the occurrence of electric power transmission line accident, a power transmission line anomaly approaching alarm system was developed to automatically alarm the operators and surveillants. The surveillance system, composed of camera, surveillance unit proper and alarm receiving portion, generates alarm and indicate hazard to the operators, when animal invades a hazardous area designated on the monitor. Wireless telegraph for the alarm transmission use used frequency around a 322MHz band with the Radio Ray law and preventive measures from noise, taken into consideration. The prototype is characterized by unnecessary ancillary fitting to the surveillance object, rare erroneous operations and high reliability. While the hazardous area can be simply designated, changed and released, as made by volume on the control panel. It is moreover easy to designate, as done by confirming the surveillance object on the display. It is also possible in multidimensional surveillance and easy to use on site. 7 figs.

  1. A technical note about Phidel: A new software for evaluating magnetic induction field generated by power lines

    International Nuclear Information System (INIS)

    Comelli, M.; Benes, M.; Bampo, A.; Villalta, R.

    2007-01-01

    The Regional Environment Protection Agency of Friuli Venezia Giulia (ARPA FVG, Italy) has performed an analysis on existing software designed to calculate magnetic induction field generated by power lines. As far as the agency's requirements are concerned the tested programs display some difficulties in the immediate processing of electrical and geometrical data supplied by plant owners, and in certain cases turn out to be inadequate in representing complex configurations of power lines. Phidel, an innovative software, tackles and works out all the above-mentioned problems. Therefore, the obtained results, when compared with those of other programs, are the closest to experimental measurements. The output data can be employed both in the GIS and Excel environments, allowing the immediate overlaying of digital cartography and the determining of the 3 and 10 μT bands, in compliance with the Italian Decree of the President of the Council of Ministers of 8 July 2003. (authors)

  2. THROUGH-THE-EARTH (TTE) COMMUNICATIONS SYSTEM AND THE IN-MINE POWER LINE (IMPL) COMMUNICATIONS SYSTEM

    International Nuclear Information System (INIS)

    Zvi H. Meiksin

    2002-01-01

    Work has progressed on both subsystems: the Through-the-Earth (TTE) Communications system and the In-Mine Power Line (IMPL) Communications system. The TTE system: The system was fabricated and repackaged as an industrial product enclosed in a commercial rugged, waterproof housing suitable for installation in mines. Features were added to the system to appeal to the preferences of different mine managers. Arrangements were made with NIOSH to install the system in the Lake Lynn underground mine for evaluation and demonstration to potential users. The IMPL system: Voice compression was successfully implemented and incorporated into the laboratory model. Compressed voice was transmitted through a power line, expanded at the receiving end, and received with high clarity

  3. Cooperative Control of Active Power Filters in Power Systems without Mutual Communication

    Czech Academy of Sciences Publication Activity Database

    Tlustý, J.; Škramlík, Jiří; Švec, J.; Valouch, Viktor

    2010-01-01

    Roč. 2010, č. 517184 (2010), s. 1-13 ISSN 1024-123X R&D Projects: GA AV ČR IAA200760703 Institutional research plan: CEZ:AV0Z20570509 Keywords : active power filter * power system * wireless cooperation Subject RIV: JA - Electronics ; Optoelectronics, Electric al Engineering Impact factor: 0.689, year: 2010 http://www.hindawi.com/journals/mpe/2010/517184.html

  4. Active learning for noisy oracle via density power divergence.

    Science.gov (United States)

    Sogawa, Yasuhiro; Ueno, Tsuyoshi; Kawahara, Yoshinobu; Washio, Takashi

    2013-10-01

    The accuracy of active learning is critically influenced by the existence of noisy labels given by a noisy oracle. In this paper, we propose a novel pool-based active learning framework through robust measures based on density power divergence. By minimizing density power divergence, such as β-divergence and γ-divergence, one can estimate the model accurately even under the existence of noisy labels within data. Accordingly, we develop query selecting measures for pool-based active learning using these divergences. In addition, we propose an evaluation scheme for these measures based on asymptotic statistical analyses, which enables us to perform active learning by evaluating an estimation error directly. Experiments with benchmark datasets and real-world image datasets show that our active learning scheme performs better than several baseline methods. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution Network

    Directory of Open Access Journals (Sweden)

    Xiaowei Wang

    2014-01-01

    Full Text Available A novel method of fault line selection based on IOS is presented. Firstly, the IOS is established by using math model, which adopted TZSC signal to replace built-in signal of duffing chaotic oscillator by selecting appropriate parameters. Then, each line’s TZSC decomposed by db10 wavelet packet to get CFB with the maximum energy principle, and CFB was solved by IOS. Finally, maximum chaotic distance and average chaotic distance on the phase trajectory are used to judge fault line. Simulation results show that the proposed method can accurately judge fault line and healthy line in strong noisy background. Besides, the nondetection zones of proposed method are elaborated.

  6. Higher capacity, lower carbon dioxide emissions. Idle power compensation in HV lines; Mehr Kapazitaet, weniger Kohlendioxid. Blindleistungskompensation bei Hochspannungsleitungen

    Energy Technology Data Exchange (ETDEWEB)

    Auer, Jan-Hendrik von [Alstom Grid GmbH, Berlin (Germany). Team Leistungselektronik und Kompensationsanlagen

    2012-07-01

    Even today, many HP lines have reached their limits. It is therefore highly urgent to find measures for optimum utilization of the available overhead transmssion capacities, e.g. by idle power compensation. Together with a filter for harmonics reduction, this will ensure higher grid stability and enhance transport capacities while reducing transport losses, thus saving money and reducing CO{sub 2} emissions. (orig./AKB)

  7. Pressure waves transient occurred in the steam generators feedwater lines of the Atucha-1 Nuclear Power Plant

    International Nuclear Information System (INIS)

    Balino, J.L.; Carrica, P.M.; Larreteguy, A.E.

    1993-01-01

    The pressure transient occurred at Atucha I Nuclear Power Plant in March 1990 is simulated. The transient was due to the fast closure of a flow control valve at the steam generators feedwater lines. The system was modelled, including the actuation of the relief valves. The minimum closure time for no actuation of the relief valves and the evolution of the velocity and piezo metric head for different cases were calculated. (author)

  8. Fetal ECG Extraction from Abdominal Signals: A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

    OpenAIRE

    Ţarălungă, Dragoş-Daniel; Ungureanu, Georgeta-Mihaela; Gussi, Ilinca; Strungaru, Rodica; Wolf, Werner

    2014-01-01

    Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the...

  9. Power line harmonic radiation observed by the DEMETER spacecraft at 50/60Hz and low harmonics

    Czech Academy of Sciences Publication Activity Database

    Němec, F.; Parrot, M.; Santolík, Ondřej

    2015-01-01

    Roč. 120, č. 10 (2015), s. 8954-8967 ISSN 2169-9380 R&D Projects: GA ČR(CZ) GA14-31899S; GA MŠk LH12231 Institutional support: RVO:68378289 Keywords : PLHR * power line harmonic radiation * DEMETER Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.318, year: 2015 http://onlinelibrary.wiley.com/doi/10.1002/2015JA021682/full

  10. A high voltage power line: the route with the least environmental and health impact. Public consultation on the plan to rebuild the 400 kV power line between Lille and Arras

    International Nuclear Information System (INIS)

    Carlier, Jean-Louis; Chardonnet, Claude

    2017-01-01

    The upgrade to double-circuit of the 400-kV power line between Avelin and Gavrelle (Northern France) was first set in motion to improve security and to adapt the network to renewable energy sources or energy transition. Since 2011, it has been the object of an unprecedented consultation process, in terms of duration as well as magnitude. From 2012 to 2015, after much discussion, the contracting authority, Reseau Transport d'Electricite (RTE), determined the line with the least consequential environmental and health effects and presented it to the 2016 spring public inquiry. Information and communication requirements were adapted at each stage of the project, to take local concerns into account. Health concerns about the magnetic fields and noise generated by the electric lines were expressed from the very beginning of the consultation and were therefore treated with special care, through knowledge-sharing, debate and specific studies. A health committee, comprising volunteers from various backgrounds, was entrusted with informing the general public and providing suggestions to RTE and the health authorities, through in-depth discussions about health issues. The committee also asked RTE to conduct studies and measure electromagnetic fields to support an informed decision. As a result, the contracting authority defined the route of the electric line based primarily on the distance between houses and the line. The committee also obtained further commitments from RTE to minimize the magnetic fields emitted by the line with a new type of pylon and to monitor the effects on the people living along the line over time. During the course of this consultation process, shared knowledge together with a continuous dialogue on local health concerns aided the search for the route with the least consequential environmental and health impact. (authors)

  11. METHODICAL APPROACHES TO THE CHOICE OF THE NEW GENERATION OF HIGH-VOLTAGE POWER TRANSMISSION LINE 220 kV OPTIONS

    Directory of Open Access Journals (Sweden)

    POSTOLATI V.M.

    2010-08-01

    Full Text Available The Transmission Power Lines of new generation are described in the article (single- compact, double-circuit compact, double-circuit Controlled Self-compensating High Voltage Transmission Power Lines (CSHVL. Basic principles of creation, design elements and comparative characteristics of the transmission lines of the new generation are described, the advantages of its are showed. Methodical approaches to the choosing of a new generation of transmission lines and facilities management FACTS are formulated. Methodical approaches to the choice of options for transmission lines 220 kV and facilities management are shown.

  12. On-Line Monitoring of Instrument Channel Performance in Nuclear Power Plant Using PEANO

    International Nuclear Information System (INIS)

    Fantoni, Paolo F.; Hoffmann, Mario; Shankar, Ramesh; Davis, Eddie L.

    2002-01-01

    On-Line monitoring evaluates instrument channel performance by assessing its consistency with other plant indications. Industry and EPRI experience at several plants has shown this overall approach to be very effective in identifying instrument channels that are exhibiting degrading or inconsistent performance characteristics. On-Line monitoring of instrument channels provides information about the condition of the monitored channels through accurate, more frequent monitoring of each channel's performance over time. This type of performance monitoring is a methodology that offers an alternate approach to traditional time-directed calibration. On-line monitoring of these channels can provide an assessment of instrument performance and provide a basis for determining when adjustments are necessary. Elimination or reduction of unnecessary field calibrations can reduce associated labor costs, reduce personnel radiation exposure and reduce the potential for miss-calibration. PEANO is a system for on-line calibration monitoring developed in the years 1995-2000 at the Institutt for energiteknikk (IFE), Norway, which makes use of Artificial Intelligence techniques for its purpose. The system has been tested successfully in Europe in off-line tests with EDF (France), Tecnatom (Spain) and ENEA (Italy). PEANO is currently installed and used for on-line monitoring at the HBWR reactor in Halden. This paper describes the results of performance tests on PEANO with real data from a US PWR plant, in the framework of a co-operation among IFE, EPRI and Edan Engineering, to evaluate the potentials of PEANO for future installations in US nuclear plants. (authors)

  13. Hierarchical modelling of line commutated power systems used in particle accelerators using Saber

    International Nuclear Information System (INIS)

    Reimund, J.A.

    1993-01-01

    This paper discusses the use of hierarchical simulation models using the program Saber trademark for the prediction of magnet ripple currents generated by the power supply/output filter combination. Modeling of an entire power system connected to output filters and particle accelerator ring magnets will be presented. Special emphasis is made on the modeling of power source imbalances caused by transformer impedance imbalances and utility variances. The affect that these imbalances have on the harmonic content of ripple current is also investigated

  14. Regulatory control of maintenance activities in Argentine nuclear power plants

    International Nuclear Information System (INIS)

    Calvo, J.C.; Caruso, G.

    2000-01-01

    The main maintenance objective is to assure that the safety features of structures, components and systems of nuclear power plants are kept as designed. Therefore, there is a direct relationship between safety and maintenance. Owing to the above mentioned, maintenance activities are considered a relevant regulatory issue for the Argentine Nuclear Regulatory Authority (ARN). This paper describes the regulatory control to maintenance activities of Argentine nuclear power plants. It also addresses essential elements for maintenance control, routine inspections, special inspections during planned outages, audits and license conditions and requirements. (author)

  15. Indirect control of a single-phase active power filter

    Directory of Open Access Journals (Sweden)

    Mihai CULEA

    2006-12-01

    Full Text Available The control of shunt active power filters using PWM inverters consists in generating a reference by separating, using different methods, the harmonics to be eliminated. The methods used are time-consuming and need dedicated control and signal processing equipments. To avoid these setbacks a new method is proposed in the paper. The active power filter is a current PWM rectifier with voltage output and with a capacitor on the DC side. The PWM rectifier is controlled so that the sum of its current and the load’s current is a sinusoid. The control block as well as simulation results are presented.

  16. Nest occupation and prey grabbing by saker falcon (Falco cherrug on power lines in the province of Vojvodina (Serbia

    Directory of Open Access Journals (Sweden)

    Puzović S.

    2008-01-01

    Full Text Available Research on nest occupation and prey grabbing by saker falcon (Falco cherrug on power lines in Vojvodina (Serbia was done in the period from 1986 to 2004. During three specially analyzed periods, saker falcon took the nests of raven (Corvus corax in 91% of a total of 22 cases of nest occupation, and those of hooded crow (Corvus corone cornix in only 9%. Saker falcon regularly grabs prey from different birds that occasionally or constantly spend time around power lines [Kestrel (Falco tinnunculus, hobby (Falco subbuteo, hooded crow (Corvus corone cornix, jack-daw (Corvus monedula, marsh harrier (Circus aeruginosus, hen harrier (Circus cyaneus, buzzard (Buteo buteo, and raven (Corvus corax]. One year a studied pair of saker falcons on a power line in Donji Srem, Serbia grabbed prey from five different species of birds. Out of a total of 40 cases of prey grabbing in the period from January to December, as much 70% of the grabbed prey was taken from kestrel (Falco tinnunculus. During the winter and early spring, prey was grabbed predominantly by males; after May, prey was sometimes grabbed by females as well. Most of the grabbed prey was common vole (Microtus arvalis.

  17. On-line transient stability assessment of large-scale power systems by using ball vector machines

    International Nuclear Information System (INIS)

    Mohammadi, M.; Gharehpetian, G.B.

    2010-01-01

    In this paper ball vector machine (BVM) has been used for on-line transient stability assessment of large-scale power systems. To classify the system transient security status, a BVM has been trained for all contingencies. The proposed BVM based security assessment algorithm has very small training time and space in comparison with artificial neural networks (ANN), support vector machines (SVM) and other machine learning based algorithms. In addition, the proposed algorithm has less support vectors (SV) and therefore is faster than existing algorithms for on-line applications. One of the main points, to apply a machine learning method is feature selection. In this paper, a new Decision Tree (DT) based feature selection technique has been presented. The proposed BVM based algorithm has been applied to New England 39-bus power system. The simulation results show the effectiveness and the stability of the proposed method for on-line transient stability assessment procedure of large-scale power system. The proposed feature selection algorithm has been compared with different feature selection algorithms. The simulation results demonstrate the effectiveness of the proposed feature algorithm.

  18. Development of An On-Line, Core Power Distribution Monitoring System

    International Nuclear Information System (INIS)

    Tunc ALdemir; Don Miller; Peng Wang

    2007-01-01

    The objective of the proposed work was to develop a software package that can construct in three-dimensional core power distributions using the signals from constant temperature power sensors distributed in the reactor core. The software developed uses a mode-based state/parameter estimation technique that is particularly attractive when there are model uncertainties and/or large signal noise. The software yields the expected value of local power at the detector locations and points in between, as well as the probability distribution of the local power density

  19. Development of An On-Line, Core Power Distribution Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Tunc ALdemir; Don Miller; Peng Wang

    2007-10-02

    The objective of the proposed work was to develop a software package that can construct in three-dimensional core power distributions using the signals from constant temperature power sensors distributed in the reactor core. The software developed uses a mode-based state/parameter estmation technique that is particularly attractive when there are model uncertainties and/or large signal noise. The software yields the expected value of local power at the detector locations and points in between, as well as the probability distribution of the local power density

  20. Coordinated Volt/Var Control in Distribution Systems with Distributed Generations Based on Joint Active and Reactive Powers Dispatch

    Directory of Open Access Journals (Sweden)

    Abouzar Samimi

    2016-01-01

    Full Text Available One of the most significant control schemes in optimal operation of distribution networks is Volt/Var control (VVC. Owing to the radial structure of distribution systems and distribution lines with a small X/R ratio, the active power scheduling affects the VVC issue. A Distribution System Operator (DSO procures its active and reactive power requirements from Distributed Generations (DGs along with the wholesale electricity market. This paper proposes a new operational scheduling method based on a joint day-ahead active/reactive power market at the distribution level. To this end, based on the capability curve, a generic reactive power cost model for DGs is developed. The joint active/reactive power dispatch model presented in this paper motivates DGs to actively participate not only in the energy markets, but also in the VVC scheme through a competitive market. The proposed method which will be performed in an offline manner aims to optimally determine (i the scheduled active and reactive power values of generation units; (ii reactive power values of switched capacitor banks; and (iii tap positions of transformers for the next day. The joint active/reactive power dispatch model for daily VVC is modeled in GAMS and solved with the DICOPT solver. Finally, the plausibility of the proposed scheduling framework is examined on a typical 22-bus distribution test network over a 24-h period.

  1. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  2. Superconduction in limiting-power synchronous generators. State, lines of development, problems

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzen, H W; Sergl, J

    1976-01-01

    The limiting power of conventional 2-pole rotary current synchronous generators is estimated. The limiting power may be raised by using superconducting materials for the field winding. After a short description of superconductive materials, the construction of a synchronous generator with a superconducting field winding is described. Finally, some problems in calculating the magnetic field and the transient behavior are discussed.

  3. Study on the evaluation index of active power reserve

    Science.gov (United States)

    Guo, Xiaorui; Liu, Jiantao; Wang, Ke; Min, Lu

    2018-01-01

    Based on the role of active reserve at different time scales, divides the evaluation dimension of active reserve. Analysis the calculation principle of traditional reliability index such as probability of system safety, lack of power shortage and electricity shortage expectancy, and studies the applicability of these indicators to evaluate the reserve capacity on different dimensions. Resolves the evaluation index of active reserve capacity from the dimensions of time dimension, spatial dimension, system state, risk degree and economy, then construct evaluation index of active reserve capacity.

  4. Nuclear Power Plant Control and Instrumentation activities in Finland

    International Nuclear Information System (INIS)

    Haapanen, P.; Wahlstroem, B.

    1990-01-01

    Finland has achieved some remarkable achievements in nuclear power production. Existing four plants have some of the best operating records in the world - high capacity factors, low occupational doses and short refuelling outages. Although public opinion was strongly turned against nuclear power after Chernobyl accident, and no decisions for new nuclear plants can be made before next elections in 1991, the nuclear option is still open. Utility companies are maintaining readiness to start new construction immediately after a positive political decision is made. One important component of the good operation history of the Finnish nuclear power plants is connected to the continuous research, development, modification and upgrading work, which is proceeding in Finland. In the following a short description is given on recent activities related to the I and C-systems of the nuclear power plants. (author). 2 tabs

  5. Active power reserves evaluation in large scale PVPPs

    DEFF Research Database (Denmark)

    Crăciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso

    2013-01-01

    The present trend on investing in renewable ways of producing electricity in the detriment of conventional fossil fuel-based plants will lead to a certain point where these plants have to provide ancillary services and contribute to overall grid stability. Photovoltaic (PV) power has the fastest...... growth among all renewable energies and managed to reach high penetration levels creating instabilities which at the moment are corrected by the conventional generation. This paradigm will change in the future scenarios where most of the power is supplied by large scale renewable plants and parts...... of the ancillary services have to be shared by the renewable plants. The main focus of the proposed paper is to technically and economically analyze the possibility of having active power reserves in large scale PV power plants (PVPPs) without any auxiliary storage equipment. The provided reserves should...

  6. Extensive Sampling of Forest Carbon using High Density Power Line Lidar

    Science.gov (United States)

    Hampton, H. M.; Chen, Q.; Dye, D. G.; Hungate, B. A.

    2013-12-01

    Estimating carbon sequestration and greenhouse gas emissions from forest management, natural processes, and disturbance is of growing interest for mitigating global warming. Ponderosa pine is common at mid-elevations throughout the western United States and is a dominant tree species in southwestern forests. Existing unmanaged "relict" sites and stand reconstructions of southwestern ponderosa pine forests from before European settlement (late 1800s) provide evidence of forests of larger trees of lower density and less vulnerability to severe fires than today's typical conditions of high densities of small trees that have resulted from a century of fire suppression. Forest treatments to improve forest health in the region include tree cutting focused on small-diameter trees (thinning), low-intensity prescribed burning, and monitoring rather than suppressing wildfires. Stimulated by several uncharacteristically-intense fires in the last decade, a collaborative process found strong stakeholder agreement to accelerate forest treatments to reduce fire risk and restore ecological conditions. Land use planning to ramp up management is underway and could benefit from quick and inexpensive techniques to inventory tree-level carbon because existing inventory data are not adequate to capture the range of forest structural conditions. Our approach overcomes these shortcomings by employing recent breakthroughs in estimating aboveground biomass from high resolution light detection and ranging (lidar) remote sensing. Lidar is an active remote sensing technique, analogous to radar, which measures the time required for a transmitted pulse of laser light to return to the sensor after reflection from a target. Lidar data can capture 3-dimensional forest structure with greater detail and broader spatial coverage than is feasible with conventional field measurements. We developed a novel methodology for extensive sampling and field validation of forest carbon, applicable to managed and

  7. Designing on-line analyzer for coal on belt conveyor using neutron activation technique

    International Nuclear Information System (INIS)

    Rony Djokorayono; Agus Cahyono

    2014-01-01

    Basic design of on-line analyzer for coal on belt conveyor using neutron activation technique has been carried out. Compared with sampling technique, this neutron activation technique has some advantages in term of analysis accuracy and time. The design activities performed include the establishment of design requirements, functional requirements, technical requirements, technical specification, detection sub-system design, data acquisition subsystem design, and operator computer console design. This program will use Nal(Tl) scintillation detector to detect gamma-rays emitted by elements in coal due to neutron activation of a neutron source, "2"5"2Cf (Californium-252). This basic design of on-line analyzer for coal on belt conveyor using neutron activation technique should be followed up with the development of detailed design, prototype construction, and field testing. (author)

  8. Active current control in wind power plants during grid faults

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Phillip C.; Rodriguez, Pedro

    2010-01-01

    Modern wind power plants are required and designed to ride through faults in electrical networks, subject to fault clearing. Wind turbine fault current contribution is required from most countries with a high amount of wind power penetration. In order to comply with such grid code requirements......, wind turbines usually have solutions that enable the turbines to control the generation of reactive power during faults. This paper addresses the importance of using an optimal injection of active current during faults in order to fulfil these grid codes. This is of relevant importance for severe...... faults, causing low voltages at the point of common coupling. As a consequence, a new wind turbine current controller for operation during faults is proposed. It is shown that to achieve the maximum transfer of reactive current at the point of common coupling, a strategy for optimal setting of the active...

  9. Analysis and Countermeasures of Wind Power Accommodation by Aluminum Electrolysis Pot-Lines in China

    Science.gov (United States)

    Zhang, Hongliang; Ran, Ling; He, Guixiong; Wang, Zhenyu; Li, Jie

    2017-10-01

    The unit energy consumption and its price have become the main obstacles for the future development of the aluminum electrolysis industry in China. Meanwhile, wind power is widely being abandoned because of its instability. In this study, a novel idea for wind power accommodation is proposed to achieve a win-win situation: the idea is for nearby aluminum electrolysis plants to absorb the wind power. The features of the wind power distribution and aluminum electrolysis industry are first summarized, and the concept of wind power accommodation by the aluminum industry is introduced. Then, based on the characteristics of aluminum reduction cells, the key problems, including the bus-bar status, thermal balance, and magnetohydrodynamics instabilities, are analyzed. In addition, a whole accommodation implementation plan for wind power by aluminum reduction is introduced to explain the theoretical value of accommodation, evaluation of the reduction cells, and the industrial experiment scheme. A numerical simulation of a typical scenario proves that there is large accommodation potential for the aluminum reduction cells. Aluminum electrolysis can accommodate wind power and remain stable under the proper technique and accommodation scheme, which will provide promising benefits for the aluminum plant and the wind energy plant.

  10. Public acceptance (PA) activities of nuclear power in Japan

    International Nuclear Information System (INIS)

    Yamada, Masafumi; Iguchi, Tatsuro

    1993-10-01

    At the first part of presentation present status of nuclear power development in Japan is described. Then results of poll on nuclear energy acceptance by population are analyzed. Further, current activities and future efforts directed to broad understanding by people benefits of nuclear energy are described. 6 figs

  11. Application of Discontinuous PWM Modulation in Active Power Filters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Asiminoaei, Lucian; Rodriguez, Pedro

    2008-01-01

    Classical discontinuous pulsewidth modulations (DPWMs) may not be efficiently applied in active power filters (APFs), because it is hard to predict the peak values of the inverter current, and consequently it is difficult to calculate the position of the clamped interval, that minimizes...

  12. The management plan preparation activities nuclear power plant in Indonesia

    International Nuclear Information System (INIS)

    Utomo

    2011-01-01

    A feasibility Study that has been updated show that two nuclear power units with each unit of power up to 1000 MWe can represent decently an economical alternative energy supply. It added that the available time schedule was quite tight so that the preparation for the development must be starting first. This paper will discuss the preparation of plans of the first nuclear power plant which includes program activities, the structure of contracts, schedules of activities and funding. From the information obtained to date that in addition to a candidate site that is ready to be built in Muria peninsula is still required another potential alternative site besides to search other complete data information. This site investigation activities completed within the time schedule was passed ''critical path'', so that these activities should be carried out intensively and obey the time. This paper describes the steps that need to be prepared to welcome the first nuclear power plant, after reviewing the various input above and apply the reality in Indonesia as the initial conditions. (author)

  13. Autonomous Active and Reactive Power Distribution Strategy in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wu, Dan; Tang, Fen; Guerrero, Josep M.

    2014-01-01

    This paper proposes an autonomous active and reactive power distribution strategy that can be applied directly on current control mode (CCM) inverters, being compatible as well with conventional droop-controlled voltage control mode (VCM) converters. In a microgrid, since renewable energy sources...

  14. Validation of Power Requirement Model for Active Loudspeakers

    DEFF Research Database (Denmark)

    Schneider, Henrik; Madsen, Anders Normann; Bjerregaard, Ruben

    2015-01-01

    . There are however many advantages that could be harvested from such knowledge like size, cost and efficiency improvements. In this paper a recently proposed power requirement model for active loudspeakers is experimentally validated and the model is expanded to include the closed and vented type enclosures...

  15. Active power decoupling with reduced converter stress for single ...

    Indian Academy of Sciences (India)

    SUJATA BHOWMICK

    Department of Electronic Systems Engineering, Indian Institute of Science, ... Single phase; double-frequency ripple; active power decoupling; reduced stress; ... sation of renewable energy sources (e.g., PV), potential ... In standard grid connected DC/AC H-bridge configuration, ..... solar inverter with reduced-size dc link.

  16. Analysis and experimental evaluation of shunt active power filter for power quality improvement based on predictive direct power control.

    Science.gov (United States)

    Aissa, Oualid; Moulahoum, Samir; Colak, Ilhami; Babes, Badreddine; Kabache, Nadir

    2017-10-12

    This paper discusses the use of the concept of classical and predictive direct power control for shunt active power filter function. These strategies are used to improve the active power filter performance by compensation of the reactive power and the elimination of the harmonic currents drawn by non-linear loads. A theoretical analysis followed by a simulation using MATLAB/Simulink software for the studied techniques has been established. Moreover, two test benches have been carried out using the dSPACE card 1104 for the classic and predictive DPC control to evaluate the studied methods in real time. Obtained results are presented and compared in this paper to confirm the superiority of the predictive technique. To overcome the pollution problems caused by the consumption of fossil fuels, renewable energies are the alternatives recommended to ensure green energy. In the same context, the tested predictive filter can easily be supplied by a renewable energy source that will give its impact to enhance the power quality.

  17. Exploring the power of rice (O. sativa x O. rufipogon) chromosome segment substitution line libraries

    Science.gov (United States)

    Transgressive variation was reported as an increase in grain yield for several rice (Oryza sativa x O. rufipogon) advanced backcross mapping populations. The objective of this study was to develop chromosome segment substitution line (CSSL) libraries to further dissect the reported transgressive var...

  18. Assumptions in quantitative analyses of health risks of overhead power lines

    NARCIS (Netherlands)

    de Jong, A.; Wardekker, J.A.; van der Sluijs, J.P.

    2012-01-01

    One of the major issues hampering the formulation of uncontested policy decisions on contemporary risks is the presence of uncertainties in various stages of the policy cycle. In literature, different lines are suggested to address the problem of provisional and uncertain evidence. Reflective

  19. Harmonic content in the variable-frequency ac power line of TFTR

    International Nuclear Information System (INIS)

    Zabar, Z.; Bronner, G.; McMurray, S.; Karady, G.

    1979-12-01

    Studies were made of the harmonic content of the current and voltage at the generator bus of the Tokamak Fusion Test Reactor. Out of numerous load scenarios, one case was considered in detail. The harmonics were found acceptable for the generator; however, control problems and substantial telecommunications interference may result, requiring appropriate control measures and shielded telecommunication lines

  20. Multi-mode operations for on-line uninterruptible power supply

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Guan, Yajuan

    2018-01-01

    In this paper, the multi-mode operation of the on-line UPS system is investigated and corresponding control strategies are proposed. The proposed control strategies are able to achieve the seamless transition in traditional normal mode, PV-aided normal mode, enhanced eco-mode and burn-in test mod...