WorldWideScience

Sample records for activation analysis wth

  1. Methylation of WTH3, a possible drug resistant gene, inhibits p53 regulated expression

    International Nuclear Information System (INIS)

    Tian, Kegui; Wang, Yuezeng; Huang, Yu; Sun, Boqiao; Li, Yuxin; Xu, Haopeng

    2008-01-01

    Previous results showed that over-expression of the WTH3 gene in MDR cells reduced MDR1 gene expression and converted their resistance to sensitivity to various anticancer drugs. In addition, the WTH3 gene promoter was hypermethylated in the MCF7/AdrR cell line and primary drug resistant breast cancer epithelial cells. WTH3 was also found to be directly targeted and up regulated by the p53 gene. Furthermore, over expression of the WTH3 gene promoted the apoptotic phenotype in various host cells. To further confirm WTH3's drug resistant related characteristics, we recently employed the small hairpin RNA (shRNA) strategy to knockdown its expression in HEK293 cells. In addition, since the WTH3 promoter's p53-binding site was located in a CpG island that was targeted by methylation, we were interested in testing the possible effect this epigenetic modification had on the p53 transcription factor relative to WTH3 expression. To do so, the in vitro methylation method was utilized to examine the p53 transgene's influence on either the methylated or non-methylated WTH3 promoter. The results generated from the gene knockdown strategy showed that reduction of WTH3 expression increased MDR1 expression and elevated resistance to Doxorubicin as compared to the original control cells. Data produced from the methylation studies demonstrated that DNA methylation adversely affected the positive impact of p53 on WTH3 promoter activity. Taken together, our studies provided further evidence that WTH3 played an important role in MDR development and revealed one of its transcription regulatory mechanisms, DNA methylation, which antagonized p53's positive impact on WTH3 expression

  2. Chemical Looping Combustion of Solid Fuels in a 10 kWth Unit Combustion de charge solide en boucle chimique dans une unité de 10 kWth

    Directory of Open Access Journals (Sweden)

    Berguerand N.

    2011-02-01

    Full Text Available The present study is based on previous results from batch experiments which were conducted in a 10 kWth chemical looping combustor for solid fuels using ilmenite, an iron titanium oxide, as the oxygen carrier with two solid fuels: a Mexican petroleum coke and a South African bituminous coal. These experiments involved testing at different fuel reactor temperatures, up to 1030°C, and different particle circulation rates between the air and fuel reactors. Previous results enabled modeling of the reactor system. In particular, it was possible to derive a correlation between measured operational data and actual circulation mass flow, as well as a model that describes the carbon capture efficiency as a function of the residence time and the char reactivity. Moreover, the kinetics of char conversion could be modeled and results showed good agreement with experimental values. The purpose of the present study was to complete these results by developing a model to predict the conversion of syngas with ilmenite in the fuel reactor. Here, kinetic data from investigations of ilmenite in TGA and batch fluidized bed reactors were used. Results were compared with the actual conversions during operation in this 10 kWth unit. Cette étude est basée sur des résultats antérieurs obtenus dans une unité de combustion de charges solides en boucle chimique d’une puissance de 10 kWth. Le transporteur d’oxygène utilisé est de l’ilménite, un minerai de fer et de titane, et les charges solides étudiées sont, d’une part, un coke de pétrole mexicain et, d’autre part, un charbon bitumineux sud africain. Les résultats expérimentaux ont été obtenus à des températures allant jusqu’à 1030°C avec différents débits de transporteur d’oxygène entre les réacteurs d’oxydation et de réduction. La modélisation de la combustion en boucle chimique de charges solides a déjà permis d’établir une corrélation entre le débit de circulation de

  3. Demonstration of a 100-kWth high-temperature solar thermochemical reactor pilot plant for ZnO dissociation

    Science.gov (United States)

    Koepf, E.; Villasmil, W.; Meier, A.

    2016-05-01

    Solar thermochemical H2O and CO2 splitting is a viable pathway towards sustainable and large-scale production of synthetic fuels. A reactor pilot plant for the solar-driven thermal dissociation of ZnO into metallic Zn has been successfully developed at the Paul Scherrer Institute (PSI). Promising experimental results from the 100-kWth ZnO pilot plant were obtained in 2014 during two prolonged experimental campaigns in a high flux solar simulator at PSI and a 1-MW solar furnace in Odeillo, France. Between March and June the pilot plant was mounted in the solar simulator and in-situ flow-visualization experiments were conducted in order to prevent particle-laden fluid flows near the window from attenuating transparency by blocking incoming radiation. Window flow patterns were successfully characterized, and it was demonstrated that particle transport could be controlled and suppressed completely. These results enabled the successful operation of the reactor between August and October when on-sun experiments were conducted in the solar furnace in order to demonstrate the pilot plant technology and characterize its performance. The reactor was operated for over 97 hours at temperatures as high as 2064 K; over 28 kg of ZnO was dissociated at reaction rates as high as 28 g/min.

  4. The Relation of Personality Traits Wth Depression Severity in Active and Non-Active Elderly Women in Tehran City

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Aslankhani

    2010-07-01

    Full Text Available Objectives: The purpose of this study was to investigate the relation of personality traits with depression in active and non – active elderly women in Tehran city. Methods & Materials: The present research is descriptive–correlation. For this purpose, 188 elderly women (94 active and 94 non - active elders in the age range of 63-82 in Tehran city availably selected as statistical sample. Measurement instrument were demographic questionnaire, Beck depression questionnaire and NEO personality traits questionnaire. Data were analyzed using descriptive statistic (mean and standard deviation and inferential statistic (independent t test, Pearson correlation and Enter multi variant Regression. Results: Results showed that there was significant difference in personality traits and depression between active women with non-active women elders (P<0.05. Also, the result showed that significant correlation between depression score on neuroticism, extroversion, openness and conscientiousness in active women elders and conscientiousness and openness in non-active women elders (P<0.05. The results of multi variant regression also indicated that openness and extroversion variants in active elders and conscientiousness variant in non-active elders have linear relationship with criteria variant (depression and can predict its changes. Conclusion: Based on results of present research, sport and physical activity can be afforded the increase of positive personality traits (for example extroversion and openness and decrease of depression in women elders.

  5. The Relation of Personality Traits Wth Depression Severity in Active and Non-Active Elderly Women in Tehran City

    OpenAIRE

    Mohammad Ali Aslankhani; Ahmad Farokhi; Parvane Shamsipour Dehkordi; Amir Shams; Mohammad Reza Ghasemian Moghaddam

    2010-01-01

    Objectives: The purpose of this study was to investigate the relation of personality traits with depression in active and non – active elderly women in Tehran city. Methods & Materials: The present research is descriptive–correlation. For this purpose, 188 elderly women (94 active and 94 non - active elders) in the age range of 63-82 in Tehran city availably selected as statistical sample. Measurement instrument were demographic questionnaire, Beck depression questionnaire and...

  6. Tar formation in a steam-O2 blown CFB gasifier and a steam blown PBFB gasifier (BabyHPR) : Comparison between different on-line measurement techniques and the off-line SPA sampling and analysis method

    NARCIS (Netherlands)

    Meng, X.; Mitsakis, P.; Mayerhofen, M.; De Jong, W.; Gaderer, M.; Verkooijen, A.H.M.; Spliethoff, H.

    2012-01-01

    Two on-line tar measurement campaigns were carried out using an atmospheric pressure 100 “”kWth steam-O2 blown circulating fluidized bed (CFB) gasifier at the Delft University of Technology (TUD) and a 30–40kWth steam blown pressurized bubbling fluidized bed (PBFB) gasifier BabyHPR (Heatpipe

  7. Improving snow water equivalent simulations in an alpine basin using blended gage precipitation and snow pillow measurements

    Science.gov (United States)

    Sohrabi, M.; Safeeq, M.; Conklin, M. H.

    2017-12-01

    Snowpack is a critical freshwater reservoir that sustains ecosystem, natural habitat, hydropower, agriculture, and urban water supply in many areas around the world. Accurate estimation of basin scale snow water equivalent (SWE), through both measurement and modeling, has been significantly recognized to improve regional water resource management. Recent advances in remote data acquisition techniques have improved snow measurements but our ability to model snowpack evolution is largely hampered by poor knowledge of inherently variable high-elevation precipitation patterns. For a variety of reasons, majority of the precipitation gages are located in low and mid-elevation range and function as drivers for basin scale hydrologic modeling. Here, we blend observed gage precipitation from low and mid-elevation with point observations of SWE from high-elevation snow pillow into a physically based snow evolution model (SnowModel) to better represent the basin-scale precipitation field and improve snow simulations. To do this, we constructed two scenarios that differed in only precipitation. In WTH scenario, we forced the SnowModel using spatially distributed gage precipitation data. In WTH+SP scenario, the model was forced with spatially distributed precipitation data derived from gage precipitation along with observed precipitation from snow pillows. Since snow pillows do not directly measure precipitation, we uses positive change in SWE as a proxy for precipitation. The SnowModel was implemented at daily time step and 100 m resolution for the Kings River Basin, USA over 2000-2014. Our results show an improvement in snow simulation under WTH+SP as compared to WTH scenario, which can be attributed to better representation in high-elevation precipitation patterns under WTH+SP. The average Nash Sutcliffe efficiency over all snow pillow and course sites was substantially higher for WTH+SP (0.77) than for WTH scenario (0.47). The maximum difference in observed and simulated

  8. Temporal Fourier transform of digital angiograms for left ventricular regional wall motion analysis

    International Nuclear Information System (INIS)

    Katayama, Kazuhiro; Guth, B.D.; Widmann, T.F.; Lee, Jong-Dae; Seitelberger, R.; Peterson, K.L.

    1988-01-01

    To determine whether or not the first harmonic of a temporal Fourier transform, applied pixel-by-pixel on time-intensity curves, can detect the subtle wall motion abnormalities due to ischemia, 6 dogs were instrumented with a micromanometer in the left ventricles, a hydraulic cuff occluder around the circumflex coronary artery, and sonomicrometers on the inferior (ischemic) and anterior (non-ischemic) walls. Left ventricular images, obtained after contrast injection via the pulmonary artery, were compared with dimension signals in control and 3 progressive levels of coronary stenosis (Stenosis I, II and III). Normalized, digital functional images (512 x 512 matrix, 256 shades of gray/pixel) were divided into anterior, apical, and inferior areas to acquire regional mean phase (degrees) and amplitude (intensity units) values. After inducing stenosis, phase in ischemic region significantly increased at all 3 levels of stenosis, whereas amplitude significantly decreased at Stenosis II and III. However, amplitude images showed clearly the topographic site of ischemia. There was a progressive increase in phase and decrease in amplitude in ischemic areas as the percent wall thickening (%WTh) fell (phase vs. %WTh: r = -0.55, p < 0.005; amplitude vs. %WTh: r = 0.71, p < 0.001). Heart rate and peak systolic pressure showed no significant changes during stenoses. We conclude that quantitative functional images, generated from a temporal Fourier transform, are sensitive to the detection of left ventricular regional wall motion abnormalities during mild, moderate, and severe degrees of ischemia. (author)

  9. Is activation analysis still active?

    International Nuclear Information System (INIS)

    Chai Zhifang

    2001-01-01

    This paper reviews some aspects of neutron activation analysis (NAA), covering instrumental neutron activation analysis (INAA), k 0 method, prompt gamma-ray neutron activation analysis (PGNAA), radiochemical neutron activation analysis (RNAA) and molecular activation analysis (MAA). The comparison of neutron activation analysis with other analytical techniques are also made. (author)

  10. Analysis of H2O in silicate glass using attenuated total reflectance (ATR) micro-FTIR spectroscopy

    Science.gov (United States)

    Lowenstern, Jacob B.; Pitcher, Bradley W.

    2013-01-01

    We present a calibration for attenuated total reflectance (ATR) micro-FTIR for analysis of H2O in hydrous glass. A Ge ATR accessory was used to measure evanescent wave absorption by H2O within hydrous rhyolite and other standards. Absorbance at 3450 cm−1 (representing total H2O or H2Ot) and 1630 cm−1 (molecular H2O or H2Om) showed high correlation with measured H2O in the glasses as determined by transmission FTIR spectroscopy and manometry. For rhyolite, wt%H2O=245(±9)×A3450-0.22(±0.03) and wt%H2Om=235(±11)×A1630-0.20(±0.03) where A3450 and A1630 represent the ATR absorption at the relevant infrared wavelengths. The calibration permits determination of volatiles in singly polished glass samples with spot size down to ~5 μm (for H2O-rich samples) and detection limits of ~0.1 wt% H2O. Basaltic, basaltic andesite and dacitic glasses of known H2O concentrations fall along a density-adjusted calibration, indicating that ATR is relatively insensitive to glass composition, at least for calc-alkaline glasses. The following equation allows quantification of H2O in silicate glasses that range in composition from basalt to rhyolite: wt%H2O=(ω×A3450/ρ)+b where ω = 550 ± 21, b = −0.19 ± 0.03, ρ = density, in g/cm3, and A3450 is the ATR absorbance at 3450 cm−1. The ATR micro-FTIR technique is less sensitive than transmission FTIR, but requires only a singly polished sample for quantitative results, thus minimizing time for sample preparation. Compared with specular reflectance, it is more sensitive and better suited for imaging of H2O variations in heterogeneous samples such as melt inclusions. One drawback is that the technique can damage fragile samples and we therefore recommend mounting of unknowns in epoxy prior to polishing. Our calibration should hold for any Ge ATR crystals with the same incident angle (31°). Use of a different crystal type or geometry would require measurement of several H2O-bearing standards to provide a crystal

  11. Effect of Gaseous Impurities on Long-Term Thermal Cycling and Aging Properties of Complex Hydrides for Hydrogen Storage

    Energy Technology Data Exchange (ETDEWEB)

    Chandra, Dhanesh [Primary Contact; Lamb, Joshua; Chien, Wen-Ming; Talekar, Anjali; and Pal, Narendra

    2011-03-28

    stored in the material after the first desorption. The activation energy was found to be 51 kJ/mol, as compared to 81 kJ/mol for pure lithium alanate. It is proposed that based on the data obtained and CALPHAD modeling that the improvement in cycling is due to the formation of pure lithium (liquid at 255°C), which is able to react with nitrogen specifically forming Li3N. The presence of nitrogen in the 80/20 molar mixtures in a hydride bed along with hydrogen causes Li to form Li3N rather than LiH, and subsequently regenerates the Li2NH phase and yields a ~10 wt.%H reversibly.

  12. Standardizing Activation Analysis: New Software for Photon Activation Analysis

    Science.gov (United States)

    Sun, Z. J.; Wells, D.; Segebade, C.; Green, J.

    2011-06-01

    Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

  13. Standardizing Activation Analysis: New Software for Photon Activation Analysis

    International Nuclear Information System (INIS)

    Sun, Z. J.; Wells, D.; Green, J.; Segebade, C.

    2011-01-01

    Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

  14. Lipoprotein cholesterol fractions are related to markers of inflammation in children and adolescents with juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Bohr, Anna-Helene; Pedersen, Freddy Karup; Nielsen, Claus Henrik

    2016-01-01

    disease activity (JADAS27), biomarkers of inflammation (myelo-related protein complex 8/14 (MRP8/14), C-reactive protein (CRP), and erythrocyte sedimentation rate (ESR)), body mass index (BMI), waist-to-height ratio (WtH ratio), and PA were explored. RESULTS: Mean values for TC, LDLc, and HDLc...... in the patients were within the normal range for Danish Children. HDLc was negatively correlated with MRP8/14 (r = -0.343, CI -0.474 to -0.201, p MRP8/14 correlated positively...... with CRP, JADAS27 and WtH ratio (r = 0.277, CI 0.142 to 0.413, p = 0.001). CONCLUSIONS: Levels of cholesterol fractions in patients with JIA were found within the normal range. Nonetheless, the level of HDLc was negatively associated with the level of the inflammatory marker MRP8/14, which is in accordance...

  15. Long-term effects of clear-cutting and biomass removal on soil water chemistry at three coniferous sites in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Zetterberg, Therese; Olsson, Bengt

    2011-07-01

    The long-term effects (27-36 years) of conventional and whole-tree harvest on soil water chemistry (50 cm depth) have been examined at three coniferous sites. One of the most important findings of our study were that WTH caused a long-term (27-30 years), but temporary loss, of exchangeable Ca{sub 2}{sup +} measured as lower soil water concentrations at 50 cm depth as a result of large amounts of Ca{sub 2}{sup +} being removed during harvest. In addition, WTH resulted in lower soil water pH and ANC. Treatment effects were also noted for SO{sub 4}{sup 2-} which could be the combined results of lower dry deposition in WTH-plots and/or increased retention in the mineral soil. The main treatment differences are temporary and had disappeared during the second study period between 2008 and 2010 (i.e. 32 to 35 years after harvest). These results are in agreement with previous soil studies carried out at the same sites. The implications of WTH effect are discussed in the context of validating model forecasts and need for ash-recycling.

  16. The release of reducing sugars and dissolved organic carbon from Spartina alterniflora Loisel in a Georgia salt marsh

    Science.gov (United States)

    Pakulski, J. Dean

    1986-04-01

    Eight monosaccharides were found to be released from both tall and short forms of Spartina alterniflora during tidal submergence including: 2-d ribose, rhamnose, ribose, mannose, arabinose, fructose, galactose and xylose. Glucose was not detected in the leachate of either growth form. Two additional monosaccharides were found but were not identified. Losses of total reducing sugars (TRS) and total dissolved organic carbon (TDOC) ranged from 14-54 μgCg -1 dry wth -1 and 42 to 850 μgCg -1 dry wth -1, respectively. Losses of individual monosaccharides were generally <5μgCg -1 dry wth -1 and varied from 0·5-17 μgCg -1 dry wth -1. Differences were observed in seasonal patterns of losses between tall and short Spartina. Tall Spartina TRS losses peaked in midsummer, while in short Spartina TRS losses peaked in the spring and fall. TDOC losses in both tall and short Spartina followed similar patterns with peak losses occurring in the spring and fall. Periods of net uptake of TDOC were observed in both growth forms in midsummer. Uptake rates varied from 142-930 μgCg -1 dry wth -1. Estimated annual losses of TDOC from tall and short Spartina were between 100-150 and 5-10 gCm -2 year -1, respectively. The magnitude and seasonal pattern of TDOC losses reported here support Turner's conclusions that losses of labile DOM from Spartina are substantial in Georgia salt marshes and related to seasonal patterns of estuarine metabolism.

  17. Bone scintigraphy in renal osteodystrophy

    International Nuclear Information System (INIS)

    de Graaf, P.; Schicht, I.M.; Pauwels, E.K.J.; te Velde, J.; de Graeff, J.

    1978-01-01

    Bone scintigraphy with Tc-99m HEDP was performed in 30 patients on maintenance hemodialysis, and the results of quantitative analysis were compared wth those of a normal group. To permit this comparison, elevated background activity due to the absence of renal radiotracer excretion was reduced by hemodialysis to levels found in the normals. Histologic proof of renal osteodystrophy had been obtained in all patients. the incidence of radiographic abnormalities was 46%, whereas abnormal scans were found in 25 patients (83%); skeletal lesions were also more pronounced and detected earlier. However, even when the scans appeared normal, the quantitative analysis showed increased skeletal activity in all patients. The total skeletal activity proved to be a good index of the severity of renal osteodystrophy and appeared dependent on both osteomalacia and hyperparathyroidism. These findings show that bone scintigraphy is a sensitive method to detect skeletal involvement in renal osteodystrophy

  18. Activation analysis. Chapter 4

    International Nuclear Information System (INIS)

    1976-01-01

    The principle, sample and calibration standard preparation, activation by neutrons, charged particles and gamma radiation, sample transport after activation, activity measurement, and chemical sample processing are described for activation analysis. Possible applications are shown of nondestructive activation analysis. (J.P.)

  19. Development and validation of a model TRIGA Mark III reactor with code MCNP5

    International Nuclear Information System (INIS)

    Galicia A, J.; Francois L, J. L.; Aguilar H, F.

    2015-09-01

    The main purpose of this paper is to obtain a model of the reactor core TRIGA Mark III that accurately represents the real operating conditions to 1 M Wth, using the Monte Carlo code MCNP5. To provide a more detailed analysis, different models of the reactor core were realized by simulating the control rods extracted and inserted in conditions in cold (293 K) also including an analysis for shutdown margin, so that satisfied the Operation Technical Specifications. The position they must have the control rods to reach a power equal to 1 M Wth, were obtained from practice entitled Operation in Manual Mode performed at Instituto Nacional de Investigaciones Nucleares (ININ). Later, the behavior of the K eff was analyzed considering different temperatures in the fuel elements, achieving calculate subsequently the values that best represent the actual reactor operation. Finally, the calculations in the developed model for to obtain the distribution of average flow of thermal, epithermal and fast neutrons in the six new experimental facilities are presented. (Author)

  20. Development and validation of a model TRIGA Mark III reactor with code MCNP5; Desarrollo y validacion de un modelo del reactor Triga Mark III con el codigo MCNP5

    Energy Technology Data Exchange (ETDEWEB)

    Galicia A, J.; Francois L, J. L. [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Aguilar H, F., E-mail: blink19871@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    The main purpose of this paper is to obtain a model of the reactor core TRIGA Mark III that accurately represents the real operating conditions to 1 M Wth, using the Monte Carlo code MCNP5. To provide a more detailed analysis, different models of the reactor core were realized by simulating the control rods extracted and inserted in conditions in cold (293 K) also including an analysis for shutdown margin, so that satisfied the Operation Technical Specifications. The position they must have the control rods to reach a power equal to 1 M Wth, were obtained from practice entitled Operation in Manual Mode performed at Instituto Nacional de Investigaciones Nucleares (ININ). Later, the behavior of the K{sub eff} was analyzed considering different temperatures in the fuel elements, achieving calculate subsequently the values that best represent the actual reactor operation. Finally, the calculations in the developed model for to obtain the distribution of average flow of thermal, epithermal and fast neutrons in the six new experimental facilities are presented. (Author)

  1. Value and limitation of digital subtraction angiography for assessment of myocardial perfusion with varying coronary stenosis

    International Nuclear Information System (INIS)

    Ohtani, Nozomu

    1988-01-01

    We examined the value of digital subtraction angiography (DSA) for the assessment of regional myocardial perfusion by comparing with regional myocardial function in 10 anesthetized dogs. With varying degrees of reduction in left circumflex coronary artery (LCX) blood flow (CBF:categories of stenosis (S1-S5)), myocardial perfusion was assessed by injecting the contrast medium(1ml by power injector) selectively into LCX, and the regional myocardium with contrast was imaged with DSA. We recorded aortic pressure (AOP) and systolic wall thickening (%WTh: sonomicrometry) in the left ventricular posterior wall simultaneously with cine pulse. On the time-density curve obtained from the myocardial regin of interest, we calculated a time interval from the contrast injection to peak concentration (TPC) and exponential washout rate (T). Under varying LCX stenosis, there were no significant change of heart rate and mean AOP and a significant linear correlations were found between %WTh and both 1/TPC(r=0.51)and 1/T(r=0.55). At S1(CBF:100-90% of control), neither %WTh nor 1/TPC differed from control, but 1/T was significantly decreased (80% of contral p<0.01). At S3(CRF:79-60%) to S5(CBF:39-0%), all%WTh, 1/TPC and 1/T were significantly decreased from control (all p<0.01), however, at S5(CBF:39-0%) the value of 1/TPC(71% of control) and 1/T(33%) were not different from that at S4, whereas %WTh was markedly reduced and took place to systolic thinning.. Therefore, in critical coronary stenosis, 1/T was more sensitive than 1/TPC or wall dynamics for assessing myocardial perfusion, however, these indices from DSA had a considerable limitation for evaluating the severity of myocardial ischemia when CBF was markedly reduced. (author)

  2. Thermodynamic evaluation of solar-geothermal hybrid power plants in northern Chile

    International Nuclear Information System (INIS)

    Cardemil, José Miguel; Cortés, Felipe; Díaz, Andrés; Escobar, Rodrigo

    2016-01-01

    Highlights: • Thermodynamic evaluation of geothermal-solar hybrid systems. • A multi-parameter analysis for different cycle configurations. • Performance comparison between two operation modes. • Overview of the technical applicability of the hybridization. - Abstract: A thermodynamic model was developed using Engineering Equation Solver (EES) to evaluate the performance of single and double-flash geothermal power plants assisted by a parabolic trough solar concentrating collector field, considering four different geothermal reservoir conditions. The benefits of delivering solar thermal energy for either the superheating or evaporating processes were analyzed in order to achieve the maximum 2"n"d law efficiency for the hybrid schemes and reduce the geothermal resource consumption for a constant power production. The results of the hybrid single-flash demonstrate that the superheating process generates additional 0.23 kWe/kWth, while supplying solar heat to evaporate the geothermal brine only delivers 0.16 kWe/kWth. The double-flash hybrid plant simulation results allow obtaining 0.29 kWe/kWth and 0.17 kW/kWth by integrating solar energy at the superheater and evaporator, respectively. In this context, the hybrid single-flash power plant is able to produce at least 20% additional power output, depending on the characteristics of the geothermal resource. Moreover, all of the cases analyzed herein increased the exergy efficiency of the process by at least 3%. The developed model also allowed assessing the reduction on the consumption of the geothermal fluid from the reservoir when the plant power output stays constant, up to 16% for the hybrid single-flash, and 19% for the hybrid double-flash. Based on the results obtained in this study, the solar-geothermal hybrid scheme increases the power generation compared with geothermal-only power plants, being an attractive solution for improved management of the geothermal reservoir depletion rates. The study shows

  3. Logging residue removal after thinning in boreal forests: long-term impact on the nutrient status of Norway spruce and Scots pine needles.

    Science.gov (United States)

    Luiro, Jukka; Kukkola, Mikko; Saarsalmi, Anna; Tamminen, Pekka; Helmisaari, Heljä-Sisko

    2010-01-01

    The aim of this study was to compare how conventional stem harvesting (CH) and whole-tree harvesting (WTH) in the first, and in some cases also in the second, thinning affect the needle nutrient status of Scots pine (Pinus sylvestris L.) and Norway spruce (Picea abies (L.) Karst.) stands in Finland. A series of 12 long-term field experiments was studied. The experiments were established during 1978-86. The effects of logging residue removal after thinnings on the needle nutrient concentrations were generally minor and without any overall trends, but there were differences between experiments. Trees tend to maintain their current needle nutrient concentrations at the same level by re-utilizing the nutrients stored in the older tissues and by changing C allocation in the whole tree. Thus, needle analysis should be combined with stem growth data in order to achieve a more comprehensive understanding of the effects of WTH on the nutrient status of trees.

  4. Automation of activation analysis

    International Nuclear Information System (INIS)

    Ivanov, I.N.; Ivanets, V.N.; Filippov, V.V.

    1985-01-01

    The basic data on the methods and equipment of activation analysis are presented. Recommendations on the selection of activation analysis techniques, and especially the technique envisaging the use of short-lived isotopes, are given. The equipment possibilities to increase dataway carrying capacity, using modern computers for the automation of the analysis and data processing procedure, are shown

  5. Activation analysis in water chemistry

    International Nuclear Information System (INIS)

    Szabo, A.; Toth, A.

    1978-01-01

    The potential applications of activation analysis in water chemistry are discussed. The principle, unit operations, the radiation sources and measuring instruments of activation analysis are described. The sensitivity of activation analysis is given in tabulated form for some elements of major importance in water chemistry and the elements readily accessible to determination by measurement of the spontaneous gamma radiation are listed. A few papers selected from the recent international professional literature are finally reviewed, in which the authors report on the results obtained by activation analysis applied to water chemistry. (author)

  6. Fast neutron activation analysis

    International Nuclear Information System (INIS)

    Pepelnik, R.

    1986-01-01

    Since 1981 numerous 14 MeV neutron activation analyses were performed at Korona. On the basis of that work the advantages of this analysis technique and therewith obtained results are compared with other analytical methods. The procedure of activation analysis, the characteristics of Korona, some analytical investigations in environmental research and material physics, as well as sources of systematic errors in trace analysis are described. (orig.) [de

  7. Impacts of post-harvest slash and live-tree retention on biomass and nutrient stocks in Populus tremuloides Michx.-dominated forests, northern Minnesota, USA

    Science.gov (United States)

    Klockow, Paul A.; D'Amato, Anthony W.; Bradford, John B.

    2013-01-01

    Globally, there is widespread interest in using forest-derived biomass as a source of bioenergy. While conventional timber harvesting generally removes only merchantable tree boles, harvesting biomass feedstock can remove all forms of woody biomass (i.e., live and dead standing woody vegetation, downed woody debris, and stumps) resulting in a greater loss of biomass and nutrients as well as more severe habitat alteration. To investigate the potential impacts of this practice, this study examined the initial impacts (pre- and post-harvest) of various levels of slash and live-tree retention on biomass and nutrient stocks, including carbon (C), nitrogen (N), calcium (Ca), potassium (K), and phosphorus (P), in Populus tremuloides Michx.-dominated forests of northern Minnesota, USA. Treatments examined included three levels of slash retention, whole-tree harvest (WTH), 20% slash retention (20SR), and stem-only harvest (SOH), factored with three levels of green-tree retention, no trees retained (NONE), dispersed retention (DISP), and aggregate retention (AGR). Slash retention was the primary factor affecting post-harvest biomass and nutrient stocks, including woody debris pools. Compared to the unharvested control, stocks of biomass, carbon, and nutrients, including N, Ca, K, and P, in woody debris were higher in all treatments. Stem-only harvests typically contained greater biomass and nutrient stocks than WTH, although biomass and nutrients within 20SR, a level recommended by biomass harvesting guidelines in the US and worldwide, generally did not differ from WTH or SOH. Biomass in smaller-diameter slash material (typically 2.5-22.5 cm in diameter) dominated the woody debris pool following harvest regardless of slash retention level. Trends among treatments in this diameter range were generally similar to those in the total woody debris pool. Specifically, SOH contained significantly greater amounts of biomass than WTH while 20SR was not different from either WTH or

  8. Draft regulatory analysis: notice of proposed rulemaking motor gasoline allocation revisions

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-06-01

    The Draft Regulatory Analysis is prepared for those proposed regulations which either may have a major impact on the general economy, individual industries, or geographic regions and levels of government, or may be significant in that they affect important DOE policy concerns and are the object of public interest. The problems and proposed solutions for the Notice of Proposed Rulemaking and Public Hearings on the Motor Gasoline Allocation Program are examined. The ERA's mandate for this program is set out in the Emergency Petroleum Allocation Act of 1973. Under this Act, the President is empowered to enforce, at his discretion, price and allocation controls on petroleum and petroleum products, including gasoline, through September 30, 1981. The Act sets the following allocation goals: protect public health; maintain public services and agricultural operations; foster competition in the petroleum industry; distribute petroleum among industry sectors and US regions equitably; and minimize economic disruption and unnecessary interference wth market mechanisms.

  9. Initial responses of rove and ground beetles (Coleoptera, Staphylinidae, Carabidae) to removal of logging residues following clearcut harvesting in the boreal forest of Quebec, Canada.

    Science.gov (United States)

    Work, Timothy T; Klimaszewski, Jan; Thiffault, Evelyne; Bourdon, Caroline; Paré, David; Bousquet, Yves; Venier, Lisa; Titus, Brian

    2013-01-01

    Increased interest in biomass harvesting for bioenergetic applications has raised questions regarding the potential ecological consequences on forest biodiversity. Here we evaluate the initial changes in the abundance, species richness and community composition of rove (Staphylinidae) and ground beetles (Carabidae), immediately following 1) stem-only harvesting (SOH), in which logging debris (i.e., tree tops and branches) are retained on site, and 2) whole-tree harvesting (WTH), in which stems, tops and branches are removed in mature balsam fir stands in Quebec, Canada. Beetles were collected throughout the summer of 2011, one year following harvesting, using pitfall traps. Overall catch rates were greater in uncut forest (Control) than either stem-only or whole-tree harvested sites. Catch rates in WTH were greater than SOH sites. Uncut stands were characterized primarily by five species: Atheta capsularis, Atheta klagesi, Atheta strigosula, Tachinus fumipennis/frigidus complex (Staphylinidae) and to a lesser extent to Pterostichus punctatissimus(Carabidae). Increased catch rates in WTH sites, where post-harvest biomass was less, were attributable to increased catches of rove beetles Pseudopsis subulata, Quedius labradorensis and to a lesser extent Gabrius brevipennis. We were able to characterize differences in beetle assemblages between harvested and non-harvested plots as well as differences between whole tree (WTH) and stem only (SOH) harvested sites where logging residues had been removed or left following harvest. However, the overall assemblage response was largely a recapitulation of the responses of several abundant species.

  10. Initial responses of rove and ground beetles (Coleoptera, Staphylinidae, Carabidae to removal of logging residues following clearcut harvesting in the boreal forest of Quebec, Canada

    Directory of Open Access Journals (Sweden)

    Timothy Work

    2013-01-01

    Full Text Available Increased interest in biomass harvesting for bioenergetic applications has raised questions regarding the potential ecological consequences on forest biodiversity. Here we evaluate the initial changes in the abundance, species richness and community composition of rove (Staphylinidae and ground beetles (Carabidae, immediately following 1 stem-only harvesting (SOH, in which logging debris (i.e., tree tops and branches are retained on site, and 2 whole-tree harvesting (WTH, in which stems, tops and branches are removed in mature balsam fir stands in Quebec, Canada. Beetles were collected throughout the summer of 2011, one year following harvesting, using pitfall traps. Overall catch rates were greater in uncut forest (Control than either stem-only or whole-tree harvested sites. Catch rates in WTH were greater than SOH sites. Uncut stands were characterized primarily by five species: Atheta capsularis, A. klagesi, A. strigosula, Tachinus fumipennis/frigidus complex (Staphylinidae and to a lesser extent to Pterostichus punctatissimus (Carabidae. Increased catch rates in WTH sites, where post-harvest biomass was less, were attributable to increased catches of rove beetles Pseudopsis subulata, Quedius labradorensis and to a lesser extent Gabrius brevipennis. We were able to characterize differences in beetle assemblages between harvested and non-harvested plots as well as differences between whole tree (WTH and stem only (SOH harvested sites where logging residues had been removed or left following harvest. However, the overall assemblage response was largely a recapitulation of the responses of several abundant species.

  11. Activation analysis in national economy

    International Nuclear Information System (INIS)

    1974-01-01

    The collected papers are based on the materials of the III All-Union Activation Analysis Meeting. The papers selected deal with the theoretical questions of the activation analysis, its hardware, latest developments in the field of automatic analysis and computer methods employment in the treatment of analytical information. Described are the new techniques for determination of a large number of elements in samples of biological and geological origin. Some results of the use of the activation analysis in various fields of science and technology are provided. The volume reflects the present status of activation analysis techniques in the USSR and might be of interest both for specialists, and for those involved in obtaining and using information on the composition of substances. (auth.)

  12. Working Towards Net Zero Energy at Fort Irwin, CA

    Science.gov (United States)

    2010-09-01

    sub- metering of their energy use. • MERV 15 – 16 air filtration would be used to reduce the impact of very fine desert dust on the heat transfer coil...use and 1,420,414 KWh/yr electrical use. The electrical use can be offset further with waste to energy cogeneration , or the use of a trigeneration...Biogas cogeneration plant (25 kWth / 50 kWth): $70,000–$90,000 Fermentation plant (300 – 400 t/yr): $150,000 7.3.2 Usable energy 200 MWh electricity

  13. Activation analysis. Detection limits

    International Nuclear Information System (INIS)

    Revel, G.

    1999-01-01

    Numerical data and limits of detection related to the four irradiation modes, often used in activation analysis (reactor neutrons, 14 MeV neutrons, photon gamma and charged particles) are presented here. The technical presentation of the activation analysis is detailed in the paper P 2565 of Techniques de l'Ingenieur. (A.L.B.)

  14. Neutron activation analysis in Romania

    International Nuclear Information System (INIS)

    Apostolescu, St.

    1985-01-01

    The following basic nuclear facilities are used for neutron activation analysis: a 2000 KW VVR-S Nuclear Reactor, a U-200 Cyclotron, a 30 MeV Betatron, several 14 MeV neutron generators and a king size High Voltage tandem Van de'Graaff accelerator. The main domains of application of the thermal neutron activation analysis are: geology and mining, processing of materials, environment and biology, achaeology. Epithermal neutron activation analysis has been used for determination of uranium and thorium in ores with high Th/U ratios or high rare earth contents. One low energy accelerator, used as 14.1 Mev neutron source, is provided with special equipmen for oxigen and low mass elements determination. An useful alternating way to support fast neutron activation analysis is an accurate theoretical description of the fast neutron induced reactions based on the statistical model (Hauser-Feubach STAPRE code) and the preequilibrium decay geometry dependent model. A gravitational sample changer has been installed at the end of a beam line of the Cyclotron, which enables to perform charged particles activation analysis for protein determination in grains

  15. Activation analysis in Greece

    International Nuclear Information System (INIS)

    Grimanis, A.P.

    1985-01-01

    A review of research and development on NAA as well as examples of applications of this method are presented, taken from work carried out over the last 21 years at the Radioanalytical Laboratory of the Department of Chemistry in the Greek Nuclear Research Center ''Demokritos''. Improved and faster radiochemical NAA methods have been developed for the determination of Au, Ni, Cl, As, Cu, U, Cr, Eu, Hg and Mo in several materials, for the simultaneous determination of Br and I; Mg, Sr and Ni; As and Cu; As, Sb and Hg; Mn, Sr and Ba; Cd and Zn; Se and As; Mo and Cr in biological materials. Instrumental NAA methods have also been developed for the determination of Ag, Cl and Na in lake waters, Al, Ca, Mg and V in wines, 7 trace elements in biological materials, 17 trace elements in sediments and 20 minor and trace elements in ceramics. A comprehensive computer program for routine activation analysis using Ge(Li) detectors have been worked out. A rather extended charged-particle activation analysis program is carried out for the last 10 years, including particle induced X-ray emission (PIXE) analysis, particle induced prompt gamma-ray emission analysis (PIGE), other nuclear reactions and proton activation analysis. A special neutron activation method, the delayed fission neutron counting method is used for the analysis of fissionable elements, as U, Th, Pu, in samples of the whole nuclear fuel cycle including geological, enriched and nuclear safeguards samples

  16. Activation analysis in food analysis. Pt. 9

    International Nuclear Information System (INIS)

    Szabo, S.A.

    1992-01-01

    An overview is presented on the application of activation analysis (AA) techniques for food analysis, as reflected at a recent international conference titled Activation Analysis and its Applications. The most popular analytical techniques include instrumental neutron AA, (INAA or NAA), radiochemical NAA (RNAA), X-ray fluorescence analysis and mass spectrometry. Data are presented for the multielemental NAA of instant soups, for elemental composition of drinking water in Iraq, for Na, K, Mn contents of various Indian rices, for As, Hg, Sb and Se determination in various seafoods, for daily microelement takeup in China, for the elemental composition of Chinese teas. Expected development trends in AA are outlined. (R.P.) 24 refs.; 8 tabs

  17. Charged-particle activation analysis

    International Nuclear Information System (INIS)

    Schweikert, E.A.

    1978-01-01

    The paper discusses the methodology and application of nuclear activation with ion beams (1 9 via 16 O( 3 He,p) 18 F, 12 C( 3 He,α) 11 C and 14 N(p,α) 11 C respectively. Recently, triton activation has been shown to be inherently still superior to 3 He activation for the determination of oxygen [ 16 O( 3 H,n) 18 F]. Lithium, boron, carbon and sulphur can be detected rapidly, nondestructively and with high sensitivity (approximately 0.25ppm for Li and B) via ''quasi-prompt'' activation based on the detection of short-lived, high-energy beta emitters (10ms 1 H( 7 Li,n) 7 Be for example. Nondestructive multielement analysis: Proton activation has the inherent potential for meeting requirements of broad elemental coverage, sensitivity (ppm and sub-ppm range) and selectivity. Up to 30 elements have been determined in Al, Co, Ag, Nb, Rh, Ta and biological samples, using 12-MeV proton activation followed by gamma-ray spectrometry. These capabilities are further enhanced with the counting of X-ray emitters, 28 elements (26 9 ) and accuracy using proton activation. 204 Pb/ 206 Pb ratios can also be determined with a relative precision of a few per cent. Although charged-particle activation analysis is a well-established trace analysis technique, broad potential capabilities remain to be explored, e.g. those arising from ultrashort-lived nuclides, heavy ion interactions and the combination of delayed and prompt methods. (author)

  18. Forensic neutron activation analysis

    International Nuclear Information System (INIS)

    Kishi, T.

    1987-01-01

    The progress of forensic neutron activation analysis (FNAA) in Japan is described. FNAA began in 1965 and during the past 20 years many cases have been handled; these include determination of toxic materials, comparison examination of physical evidences (e.g., paints, metal fragments, plastics and inks) and drug sample differentiation. Neutron activation analysis is applied routinely to the scientific criminal investigation as one of multielement analytical techniques. This paper also discusses these routine works. (author) 14 refs

  19. Neutron activation analysis of geochemical samples

    International Nuclear Information System (INIS)

    Rosenberg, R.; Zilliacus, R.; Kaistila, M.

    1983-06-01

    The present paper will describe the work done at the Technical Research Centre of Finland in developing methods for the large-scale activation analysis of samples for the geochemical prospecting of metals. The geochemical prospecting for uranium started in Finland in 1974 and consequently a manually operated device for the delayed neutron activation analysis of uranium was taken into use. During 1974 9000 samples were analyzed. The small capacity of the analyzer made it necessary to develop a completely automated analyzer which was taken into use in August 1975. Since then 20000-30000 samples have been analyzed annually the annual capacity being about 60000 samples when running seven hours per day. Multielemental instrumental neutron activation analysis is used for the analysis of more than 40 elements. Using instrumental epithermal neutron activation analysis 25-27 elements can be analyzed using one irradiation and 20 min measurement. During 1982 12000 samples were analyzed for mining companies and Geological Survey of Finland. The capacity is 600 samples per week. Besides these two analytical methods the analysis of lanthanoids is an important part of the work. 11 lanthanoids have been analyzed using instrumental neutron activation analysis. Radiochemical separation methods have been developed for several elements to improve the sensitivity of the analysis

  20. Neutron activation analysis of biological substances

    International Nuclear Information System (INIS)

    Ordogh, M.

    1978-08-01

    A Bowen cabbage sample was used as a reference material for the neutron activation studies, and the method was checked by the analysis of other biological substances (blood or serum etc.). For nondestructive measurements also some non-trace elements were determined in order to decide whether the activation analysis is a useful means for such measurements. The new activation analysis procedure was used for biomedical studies as, e.g., for trace element determination in body fluids, and for the analysis of inorganic components in air samples. (R.P.)

  1. Evaluation of nuclear reactor based activation analysis techniques

    International Nuclear Information System (INIS)

    Obrusnik, I.; Kucera, J.

    1977-09-01

    A survey is presented of the basic types of activation analysis applied in environmental control. Reactor neutron activation analysis is described (including the reactor as a neutron source, sample activation in the reactor, methodology of neutron activation analysis, sample transport into the reactor and sample packaging after irradiation, instrumental activation analysis with radiochemical separation, data measurement and evaluation, sampling and sample preparation). Sources of environmental contamination with trace elements, sampling and sample analysis by neutron activation are described. The analysis is described of soils, waters and biological materials. Methods are shown of evaluating neutron activation analysis results and of their interpretation for purposes of environmental control. (J.B.)

  2. Analysis of Precision of Activation Analysis Method

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Nørgaard, K.

    1973-01-01

    The precision of an activation-analysis method prescribes the estimation of the precision of a single analytical result. The adequacy of these estimates to account for the observed variation between duplicate results from the analysis of different samples and materials, is tested by the statistic T...

  3. Comparison of instrumental neutron activation analysis and instrumental charged-particle activation analysis for determining of Zn-68 abundance

    International Nuclear Information System (INIS)

    Rafii, H.; Mirzaei, M.; Aslani, G.R.; Kamali-Dehghan, M.; Rajamand, A-A.; Rahiminejad, A.; Mirzajani, N.; Sardari, D.; Shahabi, I.; Majidi, F.

    2004-01-01

    Gallium-67 has found important applications in nuclear medicine since last decades. The bombardment of enriched zinc-68 by proton beams in cyclotron is the most suitable method for the carrier-free production of this radionuclide. Any traces and isotopic impurities of the target cause serious radiological hazards because of their associated induced radioactivities. Trace analysis and Zn-68 content determination of the target material before any bombardment and chemical separation provide a valuable assessment of desired product. The elemental abundance evaluation of enriched isotopes is generally carried out by inductively coupled plasma-mass spectrometry method, ICP-Ms Instrumental neutron activation analysis and instrumental charged particle activation analysis. International neutron activation analysis and instrumental charged- particle activation analysis, looks be an alternative nuclear method for determining the abundance evaluation of enriched Zn-68 enrichment in two different samples has been studied by mean of international neutron activation analysis and instrumental charged- particle activation analysis . One sample was purchased from a French company, cortecnet, and the other was separated by an electromagnetic system in the Ions source department of our center, NRCAM. The neutron or proton irradiation was took place respectively in miniature neutron source reactor of Esfahan by flux of (1 to 5) 10 11 n/cm 2 .sec for 30 min and in Cyclon30 by 19 MeV proton beams of 100μA current for 12 min. The produced radioactivity was measured by HpGe detector for determination of trace impurities and evaluation of Zn-68 content in the samples. The result shows a good agreement with the reported ones by their producers and their low derivation of about ± indicates that the international neutron activation analysis and instrumental charged- particle activation analysis are relatively precise and rapid and each one can be used as a supplemental method for analyzing

  4. Proceedings of national seminar neutron activation analysis

    International Nuclear Information System (INIS)

    Agus Taftazani; Muhayatun Santoso; Budi Haryanto; Khatarina Oginawati

    2010-11-01

    Proceedings of national seminar neutron activation analysis in 2010 with the theme of the Role of Nuclear Analytical Techniques in the Field of Environment, Health and Industry. The seminar was organized by Indonesians Neutron Activation Analysis and BATAN Forum. These proceedings contain the result of environmental research in BATAN, universities and institutions associated with the application on neutron activation analysis technique. The purpose of these proceedings was as a useful source of information to spur research and development of activation analysis applications in various fields for the Indonesian welfare. There are 40 articles. (PPIKSN).

  5. Neutron activation analysis

    International Nuclear Information System (INIS)

    Taure, I.; Riekstina, D.; Veveris, O.

    2004-01-01

    Neutron activation analysis (NAA) in Latvia began to develop after 1961 when nuclear reactor in Salaspils started to work. It provided a powerful neuron source, which is necessary for this analytical method. In 1963 at Institute of Physics of the Latvian Academy of Sciences the Laboratory of Neutron Activation Analysis was formed. At the first stage of development the main tasks were of theoretical and technical aspects of NAA. Later the NAA was used to solve problems in technology, biology, and medicine. In the beginning of the 80-ties more attention was focussed to the use of NAA in the environmental research. Environmental problems stayed the main task till the closing the nuclear reactor in Salaspils in 1998 that ceased the main the existence of the laboratory and of NAA, this significant and powerful analytical method in Latvia and Baltic in general. (authors)

  6. Utilization of chemical derivatives in activation analysis

    International Nuclear Information System (INIS)

    Ehmann, W.D.

    1990-01-01

    Derivative activation analysis (DAA) is a method to enhance the sensitivity of nuclear activation analysis for the more elusive elements. It may also allow a degree of chemical speciation for the element of interest. DAA uses a preirradiation chemical reaction on the sample to initiate the formation of, or an exchange with, a chemical complex which contains a surrogate element, M. As a result, the amount of the element or the chemical species to be determined, X, is now represented by measurement of the amount of the surrogate element, M, that is made part of, or released by the complex species. The surrogate element is selected for its superior properties for nuclear activation analysis and the absence of interference reaction in its final determination by instrumental neutron activation analysis (INAA) after some preconcentration or separation chemistry. Published DAA studies have been limited to neutron activation analysis. DAA can offer the analyst some important advantages. It can determine elements, functional groups, or chemical species which cannot be determined directly by INAA, fast neutron activation analysis (FNAA), prompt gamma neutron activation analysis (PGNAA), or charged particle activation analysis (CPAA) procedures. When compared with conventional RNAA, there are fewer precautions with respect to handling of intensely radioactive samples, since the chemistry is done before the irradiation. The preirradiation chemistry may also eliminate many interferences that might occur in INAA and, through use of an appropriate surrogate element, can place the analytical gamma-ray line in an interference-free region of the gamma-ray spectrum

  7. Neutron activation analysis-comparative (NAAC)

    International Nuclear Information System (INIS)

    Zimmer, W.H.

    1979-01-01

    A software system for the reduction of comparative neutron activation analysis data is presented. Libraries are constructed to contain the elemental composition and isotopic nuclear data of an unlimited number of standards. Ratios to unknown sample data are performed by standard calibrations. Interfering peak corrections, second-order activation-product corrections, and deconvolution of multiplets are applied automatically. Passive gamma-energy analysis can be performed with the same software. 3 figures

  8. Army Training Study: Battalion Training Model Summary.

    Science.gov (United States)

    1978-08-08

    as primar’ -ind suco ndiry Wk wth .: .- 6"-’- ~~.. . . . ... --....- "- ... ....-. ,.,, - . , .. : :"’:::"" "’ v -,- ,. "-- - " tasks being integrated

  9. Development of a biotinylated DNA probe for detection of infectious hematopoietic necrosis virus

    Science.gov (United States)

    Deering, R.E.; Arakawa, C.K.; Oshima, K.H.; O'Hara, P.J.; Landolt, M.L.; Winton, J.R.

    1991-01-01

    A nonrad~oact~ve DNA probe assay was developed to detect and ~dent~fy infect~ous hernatopoiet~c necrosls virus (IHNV) uslng a dot blot format The probe a synthet~c DNA oligonucleot~de labeled enzymatlcally w~th biotln hybnd~zed spec~f~cally w~th nucleocaps~d mRNA extracted from Infected cells early In the vlrus repl~cation cycle A rap~d guan~dln~um th~ocyanate based RNA extraction method uslng RNAzol B and rn~crocentrifuge tubes eff~c~ently pioduced h~gh qual~ty RNA from 3 commonly used f~sh cell llnes, CHSE-214, CHH-1, and EPC The probe reacted with 6 d~verse ~solates of IHNV, but d~d not react \

  10. Activation analysis in Europe: present and future perspectives

    International Nuclear Information System (INIS)

    De Corte, F.; Hoste, J.

    1984-01-01

    A survey is given of the present-day European contribution to activation analysis, covering neutron activation analysis (NAA), charged particle activation analysis (CPAA) and photon activation analysis (PAA). Attention is paid to the available irradiation facilities, in particular nuclear reactors, cyclotrons and Van de Graaff accelerators, and linear electron accelerators. Mention is made of progress in fundamental fields, but the attention is especially focussed on practical applications: environmental, geochemical/cosmochemical, biological/medical, and high-purity materials. Eventually, the role of activation analysis in research projects of the Commission of the European Communities (CEC) and in the Reference Materials program of the Community Bureau of Reference (BCR) is emphasized

  11. Quality assurance techniques for activation analysis

    International Nuclear Information System (INIS)

    Becker, D.A.

    1984-01-01

    The principles and techniques of quality assurance are applied to the measurement method of activation analysis. Quality assurance is defined to include quality control and quality assessment. Plans for quality assurance include consideration of: personnel; facilities; analytical design; sampling and sample preparation; the measurement process; standards; and documentation. Activation analysis concerns include: irradiation; chemical separation; counting/detection; data collection, and analysis; and calibration. Types of standards discussed include calibration materials and quality assessment materials

  12. Neutron activation analysis of high-purity iron in comparison with chemical analysis

    International Nuclear Information System (INIS)

    Kinomura, Atsushi; Horino, Yuji; Takaki, Seiichi; Abiko, Kenji

    2000-01-01

    Neutron activation analysis of iron samples of three different purity levels has been performed and compared with chemical analysis for 30 metallic and metalloid impurity elements. The concentration of As, Cl, Cu, Sb and V detected by neutron activation analysis was mostly in agreement with that obtained by chemical analysis. The sensitivity limits of neutron activation analysis of three kinds of iron samples were calculated and found to be reasonable compared with measured values or detection limits of chemical analysis; however, most of them were above the detection limits of chemical analysis. Graphite-shielded irradiation to suppress fast neutron reactions was effective for Mn analysis without decreasing sensitivity to the other impurity elements. (author)

  13. Report on the comprehensive investigational research (at-home welfare apparatus system); Sogo chosa kenkyu (zaitaku fukushi kiki system) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    An investigational study was conducted on the research and development of an at-home welfare apparatus system. In this study, a stay experiment was carried out on whether aged or handicapped people can easily live in welfare houses into which at-home welfare apparatus was integrated, using high-tech at-home nursing apparatus systems (welfare techno house: WTH) which were installed at seven places in Japan based on `the development of a system supporting independent excretion.` In addition, the following were conducted: experiments on at-home welfare apparatus in terms of the evaluation of performance/operability/safety, physical physiology reactions, nursing burden/estimate of independence, two-way communication, examination of housing environments, etc. In WTH Chofu, a test on evaluating welfare apparatus was conducted by people with limbs paralysis and healthy case workers. In WTH Sapporo, by a working group studying biological information, examinations were made on the situation of standing up of healthy adults, old people and people with paralysis of one side of the body from various types of chairs, beds, wheel chairs, portable toilets and sitting down on them. An examination was also made on harmony with psychological function and physically adaptable function by a working group studying at-home nursing apparatus. 75 figs., 15 tabs.

  14. Activation analysis with small mobile reactors

    International Nuclear Information System (INIS)

    Chung, C.

    1990-01-01

    A small nuclear reactor (a low-power reactor without heat removal devices) usually has thermal power output under 100 W and an average in-core thermal neutron flux below 10 9 n/cm 2 s. Conventional activation analysis is restricted to determination of specific elements with large neutron capture cross sections in sizable samples. In-vivo prompt gamma activation analysis (IVPGAA) can be used for diagnosis of elemental composition of the human body, particularly the essential elements Ca, Cl, N, and P in the whole body, and toxic Cd and Hg in contaminated organs. In this chapter, activation analysis using an external neutron beam from the Tsing Hua Mobile Educational Reactor (THMER) for in vivo activation is described. Characteristics of the mobile reactor, in-vivo medical diagnosis, and radiation safety are emphasized. 17 refs, 12 figs, 3 tabs

  15. Prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Goswami, A.

    2003-01-01

    Prompt gamma neutron activation analysis (PGNAA) is a technique for the analysis of elements present in solid, liquid and gaseous samples by measuring the capture gamma rays emitted from the sample during neutron irradiation. The technique is complementary to conventional neutron activation analysis (NAA) as it can be used in number of cases where NAA fails. Though the technique was first used in sixties, the advantage of the technique was first highlighted by Lindstrom and Anderson. PGNAA is increasingly being used as a rapid, instrumental, nondestructive and multielement analysis technique. A monograph and several excellent reviews on this topic have appeared recently. In this review, an attempt has been made to bring out the essential aspects of the technique, experimental arrangement and instrumentation involved, and areas of application. Some of the results will also be presented

  16. Application of neutron activation analysis

    International Nuclear Information System (INIS)

    Dybczynski, R.

    2001-01-01

    The physical basis and analytical possibilities of neutron activation analysis have been performed. The number of applications in material engineering, geology, cosmology, oncology, criminology, biology, agriculture, environment protection, archaeology, history of art and especially in chemical analysis have been presented. The place of the method among other methods of inorganic quantitative chemical analysis for trace elements determination has been discussed

  17. Conference on instrumental activation analysis IAA 92

    International Nuclear Information System (INIS)

    Frana, J.; Obrusnik, I.

    1992-05-01

    The publication contains 26 abstracts primarily concerned with neutron activation analysis, although other analytical techniques based on X-ray fluorescence analysis, PIXE, PIGE, RBS are also included. Some contributions deal with aspects of quality practice and assurance in radioanalytical laboratories, with marketing of instrumental neutron activation analysis services, with hard- and software aspects of radiation detection, etc. (Z.S.)

  18. Neutron activation spectrometry and neutron activation analysis in analytical geochemistry

    International Nuclear Information System (INIS)

    Dulski, P.; Moeller, P.

    1975-07-01

    The present report is to show the geochemists who are interested in neutron activation spectrometry (NAS) and neutron activation analysis (NAA) which analytical possibilities these methods offer him. As a review of these analytical possibilities, a lieterature compolation is given which is subdivided into two groups: 1) rock (basic, intermediary, acid, sediments, soils and nuds, diverse minerals, tectites, meteorites and lunar material). 2) ore (Al, Au, Be, Cr, Cu, Mn, Mo, Fe, Pb, Pt, Sn, Ti, W, Zn, Zr, U and phosphate ore, polymetallic ores, fluorite, monazite and diverse ores). The applied methods as well as the determinable elements in the given materials can be got from the tables. On the whole, the literature evaluation carried out makes it clear that neutron activation spectrometry is a very useful multi-element method for the analysis of rocks. The analysis of ores, however, is subjected to great limitations. As rock analysis is very frequently of importance in prospecting for ore deposits, the NAS proves to be extremely useful for this very field of application. (orig./LH) [de

  19. Myths of anterior mediastinal masses

    African Journals Online (AJOL)

    Increased perioperative risk of airway complications is associated wth dyspnoea ... or extracorporeal membrane oxygenation (ECMO). However, such ... femoral cannulation and to establish adequate circulation and oxygenation, even with a ...

  20. Analysis of coal by neutron activation

    International Nuclear Information System (INIS)

    Burtner, D.R.

    1983-01-01

    The development of a thermal-neutron activation analysis procedure for determining elemental concentrations in whole coal samples, and the goal of combining this technique with other nuclear methods for determining a total mass balance in these and similar complex materials, is described. Problems of applying a fast-neutron activation analysis method for nitrogen are discussed, as well as an efficient procedure for drying and packaging coal samples. A thermal-neutron activation analysis (TNAA) procedure was developed for determining up to 27 elements in coal samples from the US, China, Nigeria, and Brazil. The comparator form of TNAA was applied, using a unique multielement standard, which contained 48 elements. The difference in net photopeak counts between sample and standard, due to γ-ray attenuation, was reduced by preparing this standard in an organic matrix, which simulates the composition and physical structure of the coal material. The simultaneous irradiation of several aliquots of this standard enabled high precision and accuracy to be attained. An accurate value for oxygen, determined by fast-neutron activation analysis, is used to correct for this effect in the nitrogen determination method

  1. Gamma activation analysis with microtron

    International Nuclear Information System (INIS)

    Fiderkiewicz, A.; Kierzek, J.; Parus, J.; Swiderska-Kowalczyk, M.; Wolski, W.; Zoltowski, T.

    1989-01-01

    The physical principles of gamma activation analysis, its capabilities as well as its application to analyse polymetallic ores with use of mean power microtron are presented. Limits of detection and determination for above twenty elements occurring in those ores with use of short- and longlived radioisotopes are specified. The work contains conception of construction of race-track microtron with electrons energy adjusted in 10-30 MeV range and with current not less than 20 μA. Besides the development of microtrons, the reason for choosing the race-track construction for gamma activation analysis is given. 69 refs., 35 figs., 5 tabs. (author)

  2. 7th international conference ''Modern trends in activation analysis''

    International Nuclear Information System (INIS)

    Obrusnik, I.

    1987-01-01

    The conference was held on 23-27 June, 1986 in Copenhagen (DK) with the participation of specialists from 42 countries. 175 papers were submitted covering the wide field of applications of neutron activation analysis, from novel techniques to sample preparation, information processes and control, activation techniques, light element and rare earth element determination, ultratracer analysis, quality assurance, comparator methods, and reference materials. The poster session was mainly oriented to industrial applications of activation analysis, biological applications, in vivo use of neutron activation analysis, the applications of neutron activation analysis in environmental control, criminology, etc. (E.S.)

  3. Nuclear power company activity based costing management analysis

    International Nuclear Information System (INIS)

    Xu Dan

    2012-01-01

    With Nuclear Energy Industry development, Nuclear Power Company has the continual promoting stress of inner management to the sustainable marketing operation development. In view of this, it is very imminence that Nuclear Power Company should promote the cost management levels and built the nuclear safety based lower cost competitive advantage. Activity based costing management (ABCM) transfer the cost management emphases from the 'product' to the 'activity' using the value chain analysis methods, cost driver analysis methods and so on. According to the analysis of the detail activities and the value chains, cancel the unnecessary activity, low down the resource consuming of the necessary activity, and manage the cost from the source, achieve the purpose of reducing cost, boosting efficiency and realizing the management value. It gets the conclusion from the detail analysis with the nuclear power company procedure and activity, and also with the selection to 'pieces analysis' of the important cost related project in the nuclear power company. The conclusion is that the activities of the nuclear power company has the obviously performance. It can use the management of ABC method. And with the management of the procedure and activity, it is helpful to realize the nuclear safety based low cost competitive advantage in the nuclear power company. (author)

  4. Automated activation-analysis system

    International Nuclear Information System (INIS)

    Minor, M.M.; Garcia, S.R.; Denton, M.M.

    1982-01-01

    An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day

  5. Neutron Activation Analysis with k0-standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    2001-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation concentrates on the improvement of the standardisation method and the characterisation of the neutron field as well as on the improvement of the statistical control on neutron activation analysis. Main achievements in 2000 are reported

  6. Practical considerations in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmad, N.

    2001-01-01

    Activation analysis is a technique of elemental analysis based on the measurement of characteristics radiation from radionuclides formed directly or indirectly by activation. The activation can be induced by bombarding the material with neutrons or charged particles or gamma rays. This is a well-accepted analytical technique for the determination of composition of complex materials. This technique is also sensitive at trace levels and is almost free from analytical interferences of matrix. It is used for multi-elemental determination in rocks, minerals, alloys, biological materials, geological samples, non-destructive analysis of materials and environmental samples such as water, air particulate matter, plants, soil, sediments and diets. This method is also used for production and measurements of radioisotopes in materials of known composition, for example, when radioactivation is used for nuclear reaction studies, for flux and beam intensity measurements for trace experiments and process quality control. In this article the parameters affecting the sensitivity of instrumental neutron activation analysis are briefly discussed. (author)

  7. Photon activation analysis on building materials

    International Nuclear Information System (INIS)

    Schulze, D.; Heller, W.; Kupsch, H.

    1988-01-01

    With regard to the planned construction of a new microtron, first investigations on raw materials for the aerated concrete production have been done to clear up the possibilities of photon activation analysis (PAA). Irradiations have been partly carried out on linear accelerators with a self-developed moveable activation equipment. PAA results of qualitative and quantitative elemental analysis are described. The detection of chlorine is important for studying the oversalting processes in buildings. (author)

  8. Methods of charged-particle activation analysis

    International Nuclear Information System (INIS)

    Chaudhri, M. Anwar; Chaudhri, M. Nasir; Jabbar, Q.; Nadeem, Q.

    2006-01-01

    The accuracy of Chaudhri's method for charged-particle activation analysis published in J. Radioanal. Chem. (1977) v. 37 p. 243 has been further demonstrated by extensive calculations. The nuclear reactions 12 C(d,n) 13 N, 63 Cu( 3 He,p) 65 Zn, 107 Ag(α,n) 110 In and 208 Pb(d,p) 209 Pb, the cross sections of which were easily available, have been examined for the detection of 12 C, 63 Cu, 107 Ag and 208 Pb, respectively, in matrices of Cu, Zr and Pb, at the bombarding energies of 4 - 22 MeV. The 'standard' is assumed to be in a carbon matrix. It has been clearly demonstrated that Chaudhri's method, which makes the charged particle activation analysis as simple as neutron activation analysis, provides results which are almost identical to, or only about 1-2 % different, from the results obtained using the full 'Activity Equation' involving solving complex integrals. It is valid even when the difference in the average atomic weights of matrices of the standard and the sample is large. (author)

  9. Report on achievements in fiscal 1998. Surveys on development of an at-home welfare device system to rationalize energy use; 1998 nendo energy shiyo gorika zaitaku fukushi kiki system kaihatsu chosa itaku kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    This paper analyzes and puts into order the data surveyed and discussed on thirteen Welfare Techno-Houses (WTH) from a comprehensive viewpoint. It summarizes findings contributing to development and structuring of new at-home welfare device systems of effective energy utilization type. The paper first puts into order and discusses the survey and study items available for comparison and discussion, and the survey items with originality found in the surveys of the WTH, with which relatively large number of items were surveyed and studied among the thirteen locations nationwide. Next, the paper attempts comprehensive evaluation on the achievements thereof by the following items: (1) measurement and evaluation on energy consumption of different at-home welfare devices, (2) surveys and studies on energy demand evaluation inside and outside the residential houses arranged with considerations for elderly people according to the district characteristics, (3) evaluation on daily, weekly and annual changes in energy consumption in these houses, and (4) design and development of welfare systems of effective energy utilization type for these houses. Furthermore, the paper summarizes the general attributes of the WTHs in different districts, power consumption in these at-home welfare device systems in the WTH and energy consumption of the houses, in the forms available for comparison and discussion. Then, the paper summarizes the achievements of the present surveys and studies on the thirteen WTHs all over the country. (NEDO)

  10. High-capacity neutron activation analysis facility

    International Nuclear Information System (INIS)

    Hochel, R.C.

    1979-01-01

    A high-capacity neutron activation analysis facility, the Reactor Activation Facility, was designed and built and has been in operation for about a year at one of the Savannah River Plant's production reactors. The facility determines uranium and about 19 other trace elements in hydrogeochemical samples collected in the National Uranium Resource Evaluation program. The facility has a demonstrated average analysis rate of over 10,000 samples per month, and a peak rate of over 16,000 samples per month. Uranium is determined by cyclic activation and delayed neutron counting of the U-235 fission products; other elements are determined from gamma-ray spectra recorded in subsequent irradiation, decay, and counting steps. The method relies on the absolute activation technique and is highly automated for round-the-clock unattended operation

  11. Radioactivity analysis in niobium activation foils

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, G.E.

    1995-06-01

    The motivation for this study was to measure and analyze the activity of six (6) niobium (Nb) foils (the x-rays from an internal transition in Nb-93m) and apply this information with previously obtained activation foil data. The niobium data was used to determine the epithermal to MeV range for the neutron spectrum and fluence. The foil activation data was re-evaluated in a spectrum analysis code (STAY`SL) to provide new estimates of the exposure at the Los Alamos Spallation Radiation Effect Facility (LASREF). The activity of the niobium foils was measured and analyzed at the University of Missouri-Columbia (UMC) under the direction of Professor William Miller. The spectrum analysis was performed at the University of Missouri-Rolla (UMR) by Professor Gary Mueller.

  12. Insurer’s activity as object of economic analysis

    Directory of Open Access Journals (Sweden)

    O.O. Poplavskiy

    2015-12-01

    Full Text Available The article is devoted to the substantiation of theoretical fundamentals of insurer’s analysis and peculiarities of its implementation. The attention has been focused on the important role of economic analysis in economic science which is confirmed by its active use in research and practical orientation. The author summarizes the classification and principles of insurer’s activity analysis, supplements it with specific principles for insurer’s environment, publicity and risk-orientation which enable increasingly to take into account the peculiarities of insurance relations. The paper pays attention to the specification of elements of analysis and its key directions including the analysis of insurer’s financing, the analysis of insurance operations and the analysis of investment activity which will allow the effective functioning of risk management system.

  13. Heavy ion activation analysis

    International Nuclear Information System (INIS)

    Lass, B.D.; Roche, N.G.; Sanni, A.O.; Schweikert, E.A.; Ojo, J.F.

    1982-01-01

    A report on radioactivation with ion beams of 3 6 Li and 14 N is presented with some analytical applications: the determination of C via 12 C( 6 Li,αn) 13 N; the determination of Li and Be, using 14 N activation. Next, examples, with limitations in selectivity. The detection limits using a 1 μA h of activation irradiation are 5 ppm for C and 1 ppm for Li or Be. With 9 Be suitable for analytical applications are: sup(10,11)B( 9 Be,xn) 18 F and 14 N( 9 Be,αn) 18 F. Assuming a 1 μA h irradiation the detection limits for N and B are 1.5 ng and 0.5 ng, respectively, using a 7.8 MeV 9 Be beam. For activation with 12 C, experimental results with 12 MeV 12 C beam demonstrate that the beam is best suited for 7 Li analysis by the reaction 7 Li( 12 C,n) 18 F. The detection limit for a 1 μA h irradiation is 1 ng and the only other low Z elements activated are B and C. Finally, 12 C radioactivation was further combined with autoradiography for positional analysis. The spatial resolution of the technique was estimated to be 40 μm for an exposure corresponding to 6x10 5 disintegrations. As low as 10 -12 g of Li was readily detected by autoradiography. (author)

  14. Methodological developments and applications of neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.

    2007-01-01

    The paper reviews the author's experience acquired and achievements made in methodological developments of neutron activation analysis (NAA) of mostly biological materials. These involve epithermal neutron activation analysis, radiochemical neutron activation analysis using both single- and multi-element separation procedures, use of various counting modes, and the development and use of the self-verification principle. The role of NAA in the detection of analytical errors is discussed and examples of applications of the procedures developed are given. (author)

  15. Analysis of some Egyptian cosmetic samples by fast neutron activation analysis

    International Nuclear Information System (INIS)

    Medhat, M.E.; Ali, M.A.; Hassan, M.F.

    2001-01-01

    A description of D-T neutron generator (NG) is presented. This generator can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. The concentrations of the elements Na, Mg, Al, Si, K, Cl, Ca and Fe were determined in two domestic brands of face powder by using 14 MeV neutron activation analysis

  16. Effects of Azadirachta indica leaf aqeous extract on the antioxidant ...

    African Journals Online (AJOL)

    user

    Original Paper ... compared with A while C and D were decreased compared wth B. Plasma and homogenate MDA were ..... 2017), thereby maintaining the cell membrane ... DCN revised the .... Aging processes of edible vegetable oils.

  17. The life-extension and upgrade program of the Tsing Hua Open-pool Reactor (THOR) and its research prospectives

    International Nuclear Information System (INIS)

    Kai, J.-J.

    1992-01-01

    The Tsing Hua Open-Pool Reactor (THOR) has been operated for thirty years. It is the regulations of the ROCAEC that any reactor shall be decommissioned after forty-year operation since the first fuel loading. Therefore, for extending the lifetime of THOR, it is necessary to have a life-extension program to be approved by the ROCAEC and also completed by the year of 1997. At the same time, for proceeding new research purposes, it is planed to upgrade the thermal power of THOR from 1 Wth up to 3 Wth and hopefully to reach the maximum thermal neutron flux of 5x10 13 n/cm 2 .s and the fast flux close to that order. New research directions involve (a) boron-captured neutron cancer therapy (BNCT) (b) small-angle neutron scattering (SANS). (author)

  18. Analysis of Some Egyptian Cosmetic Samples by Fast Neutron Activation Analysis

    CERN Document Server

    Medhat, M E; Fayez-Hassan, M

    2001-01-01

    A description of D-T neutron generator (NG) is presented. This generator can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. In our work, the concentration of the elements Na, Mg, Al, Si, K, Cl, Ca and Fe, were determined in two domestic brands of face powder by using 14 MeV neutron activation analysis.

  19. High-capacity neutron activation analysis facility

    International Nuclear Information System (INIS)

    Hochel, R.C.; Bowman, W.W.; Zeh, C.W.

    1980-01-01

    A high-capacity neutron activation analysis facility, the Reactor Activation Facility, was designed and built and has been in operation for about a year at one of the Savannah River Plant's production reactors. The facility determines uranium and about 19 other elements in hydrogeochemical samples collected in the National Uranium Resource Evaluation program, which is sponsored and funded by the United States Department of Energy, Grand Junction Office. The facility has a demonstrated average analysis rate of over 10,000 samples per month, and a peak rate of over 16,000 samples per month. Uranium is determined by cyclic activation and delayed neutron counting of the U-235 fission products; other elements are determined from gamma-ray spectra recorded in subsequent irradiation, decay, and counting steps. The method relies on the absolute activation technique and is highly automated for round-the-clock unattended operation

  20. Activation analysis of air particulate matter

    International Nuclear Information System (INIS)

    Alian, A.; Sansoni, B.

    1988-11-01

    This review on activation analysis of air particulate matter is an extended and updated version of a review given by the same authors in 1985. The main part is aimed at the analytical scheme and refers to rules and techniques for sampling, sample and standard preparation, irradiation and counting procedures, as well as data processing, - evaluation, and - presentation. Additional chapters deal with relative and monostandard methods, the use of activation analysis for atmosphere samples in various localities, and level of toxic and other elements in the atmosphere. The review contains 190 references. (RB)

  1. Nuclear activation analysis work at Analytical Chemistry Division: an overview

    International Nuclear Information System (INIS)

    Verma, R.; Swain, K.K.; Remya Devi, P.S.; Dalvi, Aditi A.; Ajith, Nicy; Ghosh, M.; Chowdhury, D.P.; Datta, J.; Dasgupta, S.

    2016-04-01

    Nuclear activation analysis using neutron and charged particles is used routinely for analysis and research at Analytical Chemistry Division (ACD), Bhabha Atomic Research Centre (BARC). Neutron activation analysis at ACD, BARC, Mumbai, India has been pursued since late fifties using Apsara, CIRUS, Dhruva and Critical facility Research reactors, 239 Pu-Be neutron source and neutron generator. Instrumental, Radiochemical, Chemical and Derivative neutron activation analysis approaches are adopted depending on the analyte and the matrix. Large sample neutron activation analysis as well as k 0 -based internal monostandard neutron activation analysis is also used. Charged particle activation analysis at ACD, Variable Energy Cyclotron Centre (VECC), Kolkata started in late eighties and is being used for industrial applications and research. Proton, alpha, deuteron and heavy ion beams from 224 cm room temperature Variable Energy Cyclotron are used for determination of trace elements, measurement of excitation function, thin layer activation and preparation of endohedral fullerenes encapsulated with radioactive isotopes. Analytical Chemistry Division regularly participates in Inter and Intra laboratory comparison exercises conducted by various organizations including International Atomic Energy Agency (IAEA) and the results invariably include values obtained by neutron activation analysis. (author)

  2. Analysis of active piezoelectric energy harvester

    Directory of Open Access Journals (Sweden)

    Yiliang CUI

    2018-02-01

    Full Text Available Most of the existing piezoelectric traps are designed for a narrow frequency range of vibration, but the surrounding environment has a very wide frequency range, and the frequency may also be subject to change, causing the problem of difficult to achieve energy capture or capture inefficiency. In order to solve problem, a new T-type piezoelectric cantilever is proposed as a capture energy structure in the paper. To begin with the aspects of structural design and circuit design, the static analysis, modal analysis and resonance analysis of the structure are carried out and the natural frequency and excitation frequency of the device are analyzed. The design and calculation of the power consumption and the loss of the components of the circuit are analyzed by the simulation and verification of the active capture energy circuit, and the active and passive techniques are compared and analyzed, the simulation of the active capture circuit is verified by analyzing the power consumption of the circuit and the maximum power obtained by the active technology is 5 times of that of the passive technology. And then the voltage-controlled active boundary control method can be used for interface circuit design, taking the initiative to use each piezoelectric transduction cycle triggered by the electrical boundary conditions to effectively increase the input piezoelectric pump energy, and then increase output power. The way of utilizing the active trapping of piezoelectric materials is innovated, which has a positive effect on the development of piezoelectric traps.

  3. Neutron activation analysis of Etruscan pottery

    International Nuclear Information System (INIS)

    Whitehead, J.; Silverman, A.; Ouellet, C.G.; Clark, D.D.; Hossain, T.Z.

    1992-01-01

    Neutron activation analysis (NAA) has been widely used in archaeology for compositional analysis of pottery samples taken from sites of archaeological importance. Elemental profiles can determine the place of manufacture. At Cornell, samples from an Etruscan site near Siena, Italy, are being studied. The goal of this study is to compile a trace element concentration profile for a large number of samples. These profiles will be matched with an existing data bank in an attempt to understand the place of origin for these samples. The 500 kW TRIGA reactor at the Ward Laboratory is used to collect NAA data for these samples. Experiments were done to set a procedure for the neutron activation analysis with respect to sample preparation, selection of irradiation container, definition of activation and counting parameters and data reduction. Currently, we are able to analyze some 27 elements in samples of mass 500 mg with a single irradiation of 4 hours and two sequences of counting. Our sensitivity for many of the trace elements is better than 1 ppm by weight under the conditions chosen. In this talk, details of our procedure, including quality assurance as measured by NIST standard reference materials, will be discussed. In addition, preliminary results from data treatment using cluster analysis will be presented. (author)

  4. Specific classification of financial analysis of enterprise activity

    Directory of Open Access Journals (Sweden)

    Synkevych Nadiia I.

    2014-01-01

    Full Text Available Despite the fact that one can find a big variety of classifications of types of financial analysis of enterprise activity, which differ with their approach to classification and a number of classification features and their content, in modern scientific literature, their complex comparison and analysis of existing classification have not been done. This explains urgency of this study. The article studies classification of types of financial analysis of scientists and presents own approach to this problem. By the results of analysis the article improves and builds up a specific classification of financial analysis of enterprise activity and offers classification by the following features: objects, subjects, goals of study, automation level, time period of the analytical base, scope of study, organisation system, classification features of the subject, spatial belonging, sufficiency, information sources, periodicity, criterial base, method of data selection for analysis and time direction. All types of financial analysis significantly differ with their inherent properties and parameters depending on the goals of financial analysis. The developed specific classification provides subjects of financial analysis of enterprise activity with a possibility to identify a specific type of financial analysis, which would correctly meet the set goals.

  5. Automated activation-analysis system

    International Nuclear Information System (INIS)

    Minor, M.M.; Hensley, W.K.; Denton, M.M.; Garcia, S.R.

    1981-01-01

    An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day. The system and its mode of operation for a large reconnaissance survey are described

  6. Manganese contents of soils as determined by activation analysis

    International Nuclear Information System (INIS)

    El-Kholi, A.F.; Hamdy, A.A.; Al Metwally, A.I.; El-Damaty, A.H.

    1976-01-01

    The object of this investigation is to determine total manganese by means of neutron activation analysis and evaluate this technique in comparison with the corresponding data obtained by conventional chemical analysis. Data obtained revealed that the values of total manganese in calcareous soils obtained by both chemical analysis and that by neutron activation analysis were similar. Therefore, activation analysis could be recommended as a quick laboratory, less tedious, and time consuming method for the determination of Mn content in both soils and plants than the conventional chemical techniques due to its great specificity, sensitivity and simplicity. Statistical analysis showed that there is a significant correlation at 5% probability level between manganese content in Soybean plant and total manganese determined by activation and chemical analysis giving the evidence that in the case of those highly calcareous soils of low total manganese content this fraction has to be considered as far as available soil manganese is concerned

  7. Particulate matter and neutron activation analysis

    International Nuclear Information System (INIS)

    Otoshi, Tsunehiko

    2003-01-01

    In these years, economy of East Asian region is rapidly growing, and countries in this region are facing serious environmental problems. Neutron activation analysis is known as one of high-sensitive analytical method for multi elements. And it is a useful tool for environmental research, particularly for the study on atmospheric particulate matter that consists of various constituents. Elemental concentration represents status of air, such as emission of heavy metals from industries and municipal incinerators, transportation of soil derived elements more than thousands of kilometers, and so on. These monitoring data obtained by neutron activation analysis can be a cue to evaluate environment problems. Japanese government launched National Air Surveillance Network (NASN) employing neutron activation analysis in 1974, and the data has been accumulated at about twenty sampling sites. As a result of mitigation measure of air pollution sources, concentrations of elements that have anthropogenic sources decreased particularly at the beginning of the monitoring period. However, even now, concentrations of these anthropogenic elements reflect the characteristics of each sampling site, e.g. industrial/urban, rural, and remote. Soil derived elements have a seasonal variation because of the contribution of continental dust transported by strong westerly winds prevailing in winter and spring season. The health effects associated with trace elements in particulate matter have not been well characterized. However, there is increasing evidence that particulate air pollution, especially fine portion of particles in many different cities is associated with acute mortality. Neutron activation analysis is also expected to provide useful information to this new study field related to human exposures and health risk. (author)

  8. Building an applied activation analysis centre

    International Nuclear Information System (INIS)

    Bartosek, J.; Kasparec, I.; Masek, J.

    1972-01-01

    Requirements are defined and all available background material is reported and discussed for the building up of a centre of applied activation analysis in Czechoslovakia. A detailed analysis of potential users and the centre's envisaged availability is also presented as part of the submitted study. A brief economic analysis is annexed. The study covers the situation up to the end of 1972. (J.K.)

  9. Neutron activation analysis in archaeological chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Harbottle, G [Brookhaven National Lab., Upton, NY (United States)

    1990-01-01

    There is a long history of the application of chemical analysis to archaeological problems, extending to the last years of the 18th century. The nuclear-age technique of neutron activation analysis, permitting the simultaneous, sensitive, non-destructive estimation of many elements in an archaeological specimen, has found wide application. Important advances have been made, using this technique, in locating the origins of archaeological artifacts such as ceramics, metals, obsidian and semiprecious stones, among other articles of ancient ritual and commerce. In addition, the technique of neutron activation analysis has proved to be almost ideal in studies tracing the development of ancient technologies such as glass-making and smelting. In the future, the development of data banks of analyses of archaeological materials should provide an excellent new tool in studies of prehistory.

  10. Neutron activation analysis in archaeological chemistry

    International Nuclear Information System (INIS)

    Harbottle, G.

    1990-01-01

    There is a long history of the application of chemical analysis to archaeological problems, extending to the last years of the 18th century. The nuclear-age technique of neutron activation analysis, permitting the simultaneous, sensitive, non-destructive estimation of many elements in an archaeological specimen, has found wide application. Important advantages have been made, using this technique, in locating the origins of archaeological artifacts such as ceramics, metals, obsidian and semiprecious stones, among other articles of ancient ritual and commerce. In addition, the technique of neutron activation analysis has proved to be almost ideal in studies tracing the development of ancient technologies such as glass-making and smelting. In the future, the development of data banks of analyses of archaeological materials should provide an excellent new tool in studies of prehistory. (orig.)

  11. Activation Analysis of Aluminium

    Energy Technology Data Exchange (ETDEWEB)

    Brune, Dag

    1961-01-15

    An analysis of pure aluminium alloyed with magnesium was per- formed by means of gamma spectrometry , Chemical separations were not employed. The isotopes to be determined were obtained in conditions of optimum activity by suitably choosing the time of irradiation and decay. The following elements were detected and measured quantitatively: Iron, zinc, copper, gallium, manganese, chromium, scandium and hafnium.

  12. Activation analysis of biological materials at the Activation Analysis Centre

    International Nuclear Information System (INIS)

    Kukula, F.; Obrusnik, I.; Simkova, M.; Kucera, J.; Krivanek, M.

    1976-01-01

    A review is presented of the work of the Activation Analysis Centre of the Nuclear Research Institute for different fields of the Czechoslovak economy, aimed primarily at analyzing biological materials with the purpose of determining the contents of the so-called vital trace elements and of elements which already have a toxic effect on the organism in trace concentrations. Another important field of research is the path of trace elements from the environment to the human organism. A destructive method for the simultaneous determination of 12 trace elements in 11 kinds of human tissue has been studied. (Z.M.)

  13. Forensic neutron activation analysis - the Japanese scene

    International Nuclear Information System (INIS)

    Kishi, Tohru.

    1986-01-01

    The progress of forensic neutron activation analysis/FNAA/ in Japan is described. FNAA began in 1965 and during the past 20 years many cases have been handled; these include determination of toxic materials, comparison examination of physical evidences /e.g.,paints, metal fragments, plastics and inks/ and drug sample differenciation. Neutron activation analysis is applied routinely to the scientific criminal investigation as one of multielement analytical techniques. This paper also discusses these routine works. (author)

  14. Activation analysis in the environment: Science and technology

    International Nuclear Information System (INIS)

    Lenihan, J.

    1989-01-01

    Science is disciplined curiosity. Activation analysis was created more than 50 yr ago by Hevesy's curiosity and Levi's experimental skill. Technology is the exploitation of machines and materials for the fulfillment of human needs or wants. The early history of neutron activation analysis (NAA) was greatly influenced by military requirements. Since then the technique has found applications in many disciplines, including materials science, medicine, archaeology, geochemistry, agriculture, and forensic science. More recently, neutron activation analysts, responding to increasing public interest and concern, have made distinctive contributions to the study of environmental problems. Activation analysis, though it uses some procedures derived from physics, is essentially a chemical technique. The chemical study of the environment may be reviewed under many headings; three are discussed here: 1. occupational medicine 2. health of the general public 3. environmental pollution

  15. A study of environmental analysis of urban river sediments using activation analysis

    International Nuclear Information System (INIS)

    Tanaka, Y.; Kuno, A.; Matsuo, M.

    2003-01-01

    Sediments of the Kitajukkengawa River (Sumida-ku, Tokyo, Japan) were analyzed by activation analyses. Concentrations of 36 elements for each sample were determined by instrumental neutron activation analysis (INAA) and neutron induced prompt gamma-ray analysis (PGA). Based on the correlation matrix between the elements in vertical distribution, principal component analysis (PCA) was performed. The degree of chemical weathering of silicate minerals was highest in the middle layer of the Kitajukkengawa River sediment and that adsorbed amount of trace metals such as Cd and Cr was increased along with chemical weathering. (author)

  16. Modeling activity patterns of wildlife using time-series analysis.

    Science.gov (United States)

    Zhang, Jindong; Hull, Vanessa; Ouyang, Zhiyun; He, Liang; Connor, Thomas; Yang, Hongbo; Huang, Jinyan; Zhou, Shiqiang; Zhang, Zejun; Zhou, Caiquan; Zhang, Hemin; Liu, Jianguo

    2017-04-01

    The study of wildlife activity patterns is an effective approach to understanding fundamental ecological and evolutionary processes. However, traditional statistical approaches used to conduct quantitative analysis have thus far had limited success in revealing underlying mechanisms driving activity patterns. Here, we combine wavelet analysis, a type of frequency-based time-series analysis, with high-resolution activity data from accelerometers embedded in GPS collars to explore the effects of internal states (e.g., pregnancy) and external factors (e.g., seasonal dynamics of resources and weather) on activity patterns of the endangered giant panda ( Ailuropoda melanoleuca ). Giant pandas exhibited higher frequency cycles during the winter when resources (e.g., water and forage) were relatively poor, as well as during spring, which includes the giant panda's mating season. During the summer and autumn when resources were abundant, pandas exhibited a regular activity pattern with activity peaks every 24 hr. A pregnant individual showed distinct differences in her activity pattern from other giant pandas for several months following parturition. These results indicate that animals adjust activity cycles to adapt to seasonal variation of the resources and unique physiological periods. Wavelet coherency analysis also verified the synchronization of giant panda activity level with air temperature and solar radiation at the 24-hr band. Our study also shows that wavelet analysis is an effective tool for analyzing high-resolution activity pattern data and its relationship to internal and external states, an approach that has the potential to inform wildlife conservation and management across species.

  17. Neutron activation analysis in minerals prospecting

    International Nuclear Information System (INIS)

    Gomez, H.; Duque O, J.

    1988-01-01

    One method multielemental analysis in geological samples has been developed by neutron activation analysis without using standards and by eliminating many of the error sources of the absolute method. It uses the ratio of the activities induced by mass unit, between the element in the sample and one cobalt monitor. The detection limits are good for more than thirty elements in many prospecting programs, with a standard deviation less than 7%. The neutron flux used is 2x10 11 nxcm -2 .S -1 and the HPGE detector has a relative efficiency of 20% and an energy resolution of 1.9 KeV in 1332 KeV photopeak

  18. Nuclear data for proton activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mukhammedov, S; Vasidov, A [Institute of Nuclear Physics of Academy of Sciences of Uzbekistan, 702132 Ulugbek, Tashkent (Uzbekistan); Comsan, M N.H. [Nuclear Research Centre, Inshas Cyclotron Facility, AEA 13759 Cairo (Egypt)

    2000-11-15

    The activation analysis with charged particles (ChPAA), as well as proton activation analysis (PAA), mainly requires separately irradiation of thick (thicker than the range of particles) samples and standard. Therefore for simplicity of determination of traces of chemical elements by instrumental PAA the absolute activity of the radionuclides must be known. Consequently we compilated data for nuclear decays (half life, radiation energy and intensity, type of decay, saturation factor), for nuclear reactions (excitation function, threshold energy, Q-value, yields of radionuclides), for the element under study (natural isotopic abundance of the nuclide, which yields the nuclear reaction considered, molar mass), stopping power of the irradiated material and the range of the particle that are used in the calculation of the absolute activity of the radionuclides and for the resolution of a nuclear interference problems of PAA. These data are tabulated. The tables of the radionuclides are presented in dependence on increasing atomic number and radiation energy as well as on methods of the radionuclide formation. The thick target yields of analytical radionuclides are presented versus particle energy.

  19. Nuclear data for proton activation analysis

    International Nuclear Information System (INIS)

    Mukhammedov, S.; Vasidov, A.; Comsan, M.N.H.

    2000-01-01

    The activation analysis with charged particles (ChPAA), as well as proton activation analysis (PAA), mainly requires separately irradiation of thick (thicker than the range of particles) samples and standard. Therefore for simplicity of determination of traces of chemical elements by instrumental PAA the absolute activity of the radionuclides must be known. Consequently we compilated data for nuclear decays (half life, radiation energy and intensity, type of decay, saturation factor), for nuclear reactions (excitation function, threshold energy, Q-value, yields of radionuclides), for the element under study (natural isotopic abundance of the nuclide, which yields the nuclear reaction considered, molar mass), stopping power of the irradiated material and the range of the particle that are used in the calculation of the absolute activity of the radionuclides and for the resolution of a nuclear interference problems of PAA. These data are tabulated. The tables of the radionuclides are presented in dependence on increasing atomic number and radiation energy as well as on methods of the radionuclide formation. The thick target yields of analytical radionuclides are presented versus particle energy

  20. Staged, High-Pressure Oxy-Combustion Technology: Development and Scale-Up

    Energy Technology Data Exchange (ETDEWEB)

    Axelbaum, Richard [Washington Univ., St. Louis, MO (United States); Kumfer, Benjamin [Washington Univ., St. Louis, MO (United States); Gopan, Akshay [Washington Univ., St. Louis, MO (United States); Yang, Zhiwei [Washington Univ., St. Louis, MO (United States); Phillips, Jeff [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Pint, Bruce [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-12-29

    The immediate need for a high efficiency, low cost carbon capture process has prompted the recent development of pressurized oxy-combustion. With a greater combustion pressure the dew point of the flue gas is increased, allowing for effective integration of the latent heat of flue gas moisture into the Rankine cycle. This increases the net plant efficiency and reduces costs. A novel, transformational process, named Staged, Pressurized Oxy-Combustion (SPOC), achieves additional step changes in efficiency and cost reduction by significantly reducing the recycle of flue gas. The research and development activities conducted under Phases I and II of this project (FE0009702) include: SPOC power plant cost and performance modeling, CFD-assisted design of pressurized SPOC boilers, theoretical analysis of radiant heat transfer and ash deposition, boiler materials corrosion testing, construction of a 100 kWth POC test facility, and experimental testing. The results of this project have advanced the technology readiness level (TRL) of the SPOC technology from 1 to 5.

  1. Modelling transport of chokka squid (Loligo reynaudii) paralarvae off South Africa: reviewing, testing and extending the ‘Westward Transport Hypothesis'

    CSIR Research Space (South Africa)

    Martins, RS

    2013-08-01

    Full Text Available hydrodynamic model (ROMS) to test the WTH and assessed four factors that might influence successful transport – Release Area, Month, Specific Gravity (body density) and Diel Vertical Migration (DVM) – in numerical experiments that estimated successful transport...

  2. Neutron activation analysis of artefacts

    International Nuclear Information System (INIS)

    Mohd Suhaimi Hamzah; Shamsiah Abd Rahman

    2004-01-01

    The paper discussed the utilization of neutron activation analysis in this field. NAA, an analytical technique which analyzing the elements in the sample without any chemical treatment. It is sensitive and accurate. Archaeological objects i.e. ceramics, historical building materials, metals, etc can be analyze with this technique. The analysis results were presented in form of characterization of the artefacts in chemical profiles, which can present the information of the origin of the artefacts as well as it originality. (Author)

  3. Development of educational program for neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Ryel, Sung; Kang, Young Hwan; Lee, Kil Yong; Yeon, Yeon Yel; Cho, Seung Yeon

    2000-08-01

    This technical report is developed to apply an educational and training program for graduate student and analyst utilizing neutron activation analysis. The contents of guide book consists of five parts as follows; introduction, gamma-ray spectrometry and measurement statistics, its applications, to understand of comprehensive methodology and to utilize a relevant knowledge and information on neutron activation analysis

  4. Development of educational program for neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Ryel, Sung; Kang, Young Hwan; Lee, Kil Yong; Yeon, Yeon Yel; Cho, Seung Yeon

    2000-08-01

    This technical report is developed to apply an educational and training program for graduate student and analyst utilizing neutron activation analysis. The contents of guide book consists of five parts as follows; introduction, gamma-ray spectrometry and measurement statistics, its applications, to understand of comprehensive methodology and to utilize a relevant knowledge and information on neutron activation analysis.

  5. Application of activation techniques to biological analysis

    International Nuclear Information System (INIS)

    Bowen, H.J.M.

    1981-01-01

    Applications of activation analysis in the biological sciences are reviewed for the period of 1970 to 1979. The stages and characteristics of activation analysis are described, and its advantages and disadvantages enumerated. Most applications involve activation by thermal neutrons followed by either radiochemical or instrumental determination. Relatively little use has been made of activation by fast neutrons, photons, or charged particles. In vivo analyses are included, but those based on prompt gamma or x-ray emission are not. Major applications include studies of reference materials, and the elemental analysis of plants, marine biota, animal and human tissues, diets, and excreta. Relatively little use of it has been made in biochemistry, microbiology, and entomology, but it has become important in toxicology and environmental science. The elements most often determined are Ag, As, Au, Br, Ca, Cd, Cl, Co, Cr, Cs, Cu, Fe, Hg, I, K, Mn, Mo, Na, Rb, Sb, Sc, Se, and Zn, while few or no determinations of B, Be, Bi, Ga, Gd, Ge, H, In, Ir, Li, Nd, Os, Pd, Pr, Pt, Re, Rh, Ru, Te, Tl, or Y have been made in biological materials

  6. Conference on instrumental activation analysis - IAA 89

    International Nuclear Information System (INIS)

    Vobecky, M.; Obrusnik, I.

    1989-05-01

    The proceedings contain 40 abstracts of papers all of which have been incorporated in INIS. The papers were centred on the applications of radioanalytical methods, especialy on neutron activation analysis, X-ray fluorescence analysis, PIXE analysis and tracer techniques in biology, medicine and metallurgy, measuring instruments including microcomputers, and data processing methods. (J.P.)

  7. Activation analysis of coal with the help of a microtron

    International Nuclear Information System (INIS)

    Sodnom, N.; Gehrbish, Sh.

    1989-01-01

    Activation analysis techniques using microtron bremsstrahlung and photoneutrons have been developed for the multielemental analysis of coal. Analysis data for coals from 17 mines of Mongolia are presented. The chlorine content of coal and the distribution of elements in coal burning products are determined. Control experiments were performed at the reactors IBR-2 and ARGUS. The results of the gamma activation analysis are compared with neutron activation and X-ray fluorescence analyses data. It is shown that the microtron irradiation techniques employed provide a satisfactory multielemental basis for the analysis of coal. (author)

  8. Nondestructive neutron activation analysis of mineral materials. III

    International Nuclear Information System (INIS)

    Randa, Z.; Benada, J.; Kuncir, J.; Vobecky, M.

    1979-01-01

    A description is presented of sampling, calibration standards, the method of activation and measurement, activation product identification, the respective nuclear reactions, interfering admixtures, and pre-activation operations. The analysis is described of sulphides, halogenides, oxides, sulphates, carbonates, phosphates, silicates, aluminosilicates, composite minerals containing lanthanides, rocks, tektites, meteors, and plant materials. The method allows determining mainly F, Mg, Al, Ti, V, Nb, Rh, and I which cannot be determined by long-term activation (LTA). It is more sensitive than LTA in determining Ca, Cu, In, and Dy. The analysis takes less time, irradiation and measurement are less costly. The main mineral components are quickly found. (M.K.)

  9. Studies in heavy ion activation analysis Pt. 4

    International Nuclear Information System (INIS)

    Lass, B.D.; Ojo, J.F.; Schweikert, E.A.

    1980-01-01

    The use of 7 MeV 6 Li + for heavy ion activation analysis was investigated. A survey of reactions, involving targets of lithium through oxygen inclusive, were studied for production of β + radioactivation products with half-lives of 10 1 -10 5 seconds. Specific activities for all reactions under the experimental conditions are reported and their use for analysis is assessed. (author)

  10. Prompt gamma activation analysis (PGAA) and short-lived neutron activation analysis (NAA) applied to the characterization of legacy materials

    International Nuclear Information System (INIS)

    English, G.A.; Firestone, R.B.; Perry, D.L.; Reijonen, J.P.; Ka-Ngo Leung; Garabedian, G.F.; Molnar, G.L.; Revay, Zs.

    2008-01-01

    Without quality historical records that provide the composition of legacy materials, the elemental and/or chemical characterization of such materials requires a manual analytical strategy that may expose the analyst to unknown toxicological hazards. In addition, much of the existing legacy inventory also incorporates radioactivity, and, although radiological composition may be determined by various nuclear-analytical methods, most importantly, gamma-spectroscopy, current methods of chemical characterization still require direct sample manipulation, thereby presenting special problems with broad implications for both the analyst and the environment. Alternately, prompt gamma activation analysis (PGAA) provides a 'single-shot' in-situ, non-destructive method that provides a complete assay of all major entrained elemental constituents. Additionally, neutron activation analysis (NAA) using short-lived activation products complements PGAA and is especially useful when NAA activation surpasses the PGAA in elemental sensitivity. (author)

  11. Prompt gamma activation analysis (PGAA) and short-lived neutron activation analysis (NAA) applied to the characterization of legacy materials

    International Nuclear Information System (INIS)

    Firestone, Richard B; English, G.A.; Firestone, R.B.; Perry, D.L.; Reijonen, J.P.; Leung, Ka-Ngo; Garabedian, G.F.; Molnar, G.L.; Revay, Zs.

    2008-01-01

    Without quality historical records that provide the composition of legacy materials, the elemental and/or chemical characterization of such materials requires a manual analytical strategy that may expose the analyst to unknown toxicological hazards. In addition, much of the existing legacy inventory also incorporates radioactivity, and, although radiological composition may be determined by various nuclear-analytical methods, most importantly, gamma-spectroscopy, current methods of chemical characterization still require direct sample manipulation, thereby presenting special problems with broad implications for both the analyst and the environment. Alternately, prompt gamma activation analysis (PGAA) provides a 'single-shot' in-situ, non-destructive method that provides a complete assay of all major entrained elemental constituents.1-3. Additionally, neutron activation analysis (NAA) using short-lived activation products complements PGAA and is especially useful when NAA activation surpasses the PGAA in elemental sensitivity

  12. Neutron activation analysis of geological material

    International Nuclear Information System (INIS)

    Greef, G.J.

    1977-05-01

    In neutron activation analysis the precision and accuracy of results are often misleading, since only the statistical errors which accompany the measuring of radioactivity are taken into consideration. Several other factors can, however, also influence precision and accuracy. It was found that a geological sample was contaminated with the construction material of the mill in which it had been pulverised. Several geometrical differences which could possibly play a role were also investigated. Impurities in the irradiation containers affect the determination of some elements in the samples; the contamination materials in quarts irradiation tubes were determined. The flux gradients which may effect the relative activities of the samples and standards were measured. Suitable standards are necessary to ensure accurate analyses of geological material. Available natural standards were critically evaluated and several methods were investigated by which synthetic standards may be prepared. In order to accurately determine gallium, lanthanum and samarium by means of neutron activation analysis, sodium first had to be removed. After irradiation the sample was dissolved in a mixture of acids and the soidium absorbed from the solution on a hydrated antimony pentoxide column. Gallium, lanthanum and samarium activities were measured by means of precision gamma-spectrometry

  13. Analysis by neutronic activation of the active principles of MIBI

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.T.; Moreno Bermudez, J.; Ribeiro Guevara, S.; Molina Insfran, J.; Perez Zayas, G.

    1997-01-01

    In the present job the obtained results are shown through the application of an analysis by neutronic activation, in their instrumental variant, for the determination of the elementary composition of three Cuban radiopharmaceuticals. (author) [es

  14. Instrumental neutron activation analysis - a routine method

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1983-01-01

    This thesis describes the way in which at IRI instrumental neutron activation analysis (INAA) has been developed into an automated system for routine analysis. The basis of this work are 20 publications describing the development of INAA since 1968. (Auth.)

  15. Physical basis for prompt-neutron activation analysis

    International Nuclear Information System (INIS)

    Chrien, R.E.

    1982-01-01

    The technique called prompt ν-ray neutron activation analysis has been applied to rapid materials analysis. The radiation following the neutron radiation capture is prompt in the sense that the nuclear decay time is on the order of 10 - 15 second, and thus the technique is not strictly activation, but should be called radiation neutron capture spectroscopy or neutron capture ν-ray spectroscopy. This paper reviews the following: sources and detectors, theory of radiative capture, nonstatistical capture, giant dipole resonance, fast neutron capture, and thermal neutron capture ν-ray spectra. 14 figures

  16. Study on neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Cho, Seung Yeon

    1993-01-01

    Environmental samples were analyzed quantitatively by neutron activation analysis using high resolution γ-ray spectrometry. The accuracy and precision of the method were checked by the analysis of reference materials, Urban Particulate Matter (NBS SRM 1648) and Coalfly ash (NBS SRM 1633a). Airborne particulates collected for 6 months with low volume air sampler at the outer area of Seoul were analyzed as the start of full scale airborne particulates research. We analyzed 19 trace elements from the samples and the NAA method was confirmed to be utilized for environmental pollution research. (Author)

  17. A new facility for rapid neutron activation analysis

    International Nuclear Information System (INIS)

    Zeisler, R.; Makarewicz, M.; Grass, F.; Casta, J.

    1996-01-01

    Many research groups have undertaken efforts on the utilization of short-lived nuclides in a broad spectrum of neutron activation analysis (NAA) applications. The advantages of these approaches are obvious because the information on the sample can be extracted more rapidly. In addition to its other advantages, NAA can become extremely competitive in price and analysis time. Nevertheless, NAA with short-lived nuclides has not gained broad popularity, perhaps because of some difficulties in accuracy and the availability of suitable irradiation facilities. This report discusses the ASTRA reactor for neutron activation analysis capabilities

  18. Neutron activation analysis for antimetabolites. [in food samples

    Science.gov (United States)

    1973-01-01

    Determination of metal ion contaminants in food samples is studied. A weighed quantity of each sample was digested in a concentrated mixture of nitric, hydrochloric and perchloric acids to affect complete solution of the food products. The samples were diluted with water and the pH adjusted according to the specific analysis performed. The samples were analyzed by neutron activation analysis, polarography, and atomic absorption spectrophotometry. The solid food samples were also analyzed by neutron activation analysis for increased sensitivity and lower levels of detectability. The results are presented in tabular form.

  19. Neutron activation analysis: principle and methods

    International Nuclear Information System (INIS)

    Reddy, A.V.R.; Acharya, R.

    2006-01-01

    Neutron activation analysis (NAA) is a powerful isotope specific nuclear analytical technique for simultaneous determination of elemental composition of major, minor and trace elements in diverse matrices. The technique is capable of yielding high analytical sensitivity and low detection limits (ppm to ppb). Due to high penetration power of neutrons and gamma rays, NAA experiences negligible matrix effects in the samples of different origins. Depending on the sample matrix and element of interest NAA technique is used non-destructively, known as instrumental neutron activation analysis (INAA), or through chemical NAA methods. The present article describes principle of NAA, different methods and gives a overview some applications in the fields like environment, biology, geology, material sciences, nuclear technology and forensic sciences. (author)

  20. Trace element analysis of common salt using neutron activation analysis

    International Nuclear Information System (INIS)

    Usman, K.

    1993-01-01

    Instrumental Fast Neutron Activation Analysis (IFNAA) technique has been used in the qualitative and quantitative determination of the impurity elements in common salt. Samples of the different types of common salt processed in Nigeria and some of those imported into the country were used. The type A711 KAMAN neutron generator and a high-purity Germanium (HpGe) gamma spectrometer available at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria has been used. The ORTEC ADCAM 100 Emulation Software (Maestro) was used in the qualitative measurement of the detected elements. The G.R.G Activation Analysis System by G. R. Gilmore, 1987, was used in the quantitative determination of the elements detected by relative method. Aluminium and arsenic were detected and measured

  1. Neutron activation analysis of atmospheric aerosol

    International Nuclear Information System (INIS)

    Obrusnik, I.

    1986-01-01

    Neutron activation analysis (NAA) is a modern analytical method well suited for the analysis of atmospheric aerosols. Particular steps of the NAA procedure and especially different types of aerosol sampling and sample preparation for analysis are discussed in detail. Several possible NAA techniques are described and the advantages of a purely instrumental technique with short and long irradiation are pointed out. Important performance characteristics of the NAA method such as precision, accuracy, sensitivity and detection limits are also discussed. Different applications of NAA in environmental studies are reviewed. (author)

  2. Instrumental neutron activation analysis as a routine method for rock analysis

    International Nuclear Information System (INIS)

    Rosenberg, R.J.

    1977-06-01

    Instrumental neutron activation methods for the analysis of geological samples have been developed. Special emphasis has been laid on the improvement of sensitivity and accuracy in order to maximize tha quality of the analyses. Furthermore, the procedures have been automated as far as possible in order to minimize the cost of the analysis. A short review of the basic literature is given followed by a description of the principles of the method. All aspects concerning the sensitivity are discussed thoroughly in view of the analyst's possibility of influencing them. Experimentally determined detection limits for Na, Al, K, Ca, Sc, Cr, Ti, V, Mn, Fe, Ni, Co, Rb, Zr, Sb, Cs, Ba, La, Ce, Nd, Sm, Eu, Gd, Tb, Dy, Yb, Lu, Hf, Ta, Th and U are given. The errors of the method are discussed followed by actions taken to avoid them. The most significant error was caused by flux deviation, but this was avoided by building a rotating sample holder for rotating the samples during irradiation. A scheme for the INAA of 32 elements is proposed. The method has been automated as far as possible and an automatic γ-spectrometer and a computer program for the automatic calculation of the results are described. Furthermore, a completely automated uranium analyzer based on delayed neutron counting is described. The methods are discussed in view of their applicability to rock analysis. It is stated that the sensitivity varies considerably from element to element and instrumental activation analysis is an excellent method for the analysis of some specific elements like lanthanides, thorium and uranium but less so for many other elements. The accuracy is good varying from 2% to 10% for most elements. Instrumental activation analysis for most elements is rather an expensive method there being, however, a few exceptions. The most important of these is uranium. The analysis of uranium by delayed neutron counting is an inexpensive means for the analysis of large numbers of samples needed for

  3. Storage and pre-neutron-activation-analysis treatment for trace-element analysis in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.

    1985-01-01

    The problems regarding storage and pre-neutron-activation-analysis treatment for the elements aluminum, calcium, vanadium, selenium, copper, iodine, zinc, manganese, and magnesium in a urine matrix are reviewed. The type of collection and storage procedure and pre-neutron activation analysis treatment of urine depend on the specific trace element; that is, its inherent physical and chemical properties. Specifically polyethylene in teflon containers are the most suitable for general determinations. Whether any preservative is added would depend upon the stability of the trace element and its tendency for surface adsorption. Preferably, preservatives should contain no radioactivatable elements for maximum efficacy. Freeze drying or packing urine shipments under dry ice needs to be explored on an individual basis. Each pre- or post-neutron activation analysis treatment is specific and optimized for the trace element analyzed

  4. Neutron activation analysis for environmental sample in Thailand

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Nouchpramool, Sunun; Bunprapob, Supamatthree; Sumitra, Tatchai

    2003-01-01

    Neutron Activation Analysis has been applied for the trace elements analysis in environmental samples. Thirty three samples of airborne particulate were collected every week at Ongkharak Nuclear Research Center (ONRC) during the period of June 1998 to March 1999. The Ti, I, Mg, Na, V, K, Cl, Al, Mn, Ca, As, Sm, Sb, Br, La, Ce, Th, Cr, Cs, Sc, Rb, Fe, Zn and Co were analyzed by Neutron Activation Analysis utilizing 2 MW TRIGA MARK III research reactor. The certified reference materials 1632a and 1633a from National Bureau of Standard were select as standard. (author)

  5. INDUSTRIAL/MILITARY ACTIVITY-INITIATED ACCIDENT SCREENING ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    D.A. Kalinich

    1999-09-27

    Impacts due to nearby installations and operations were determined in the Preliminary MGDS Hazards Analysis (CRWMS M&O 1996) to be potentially applicable to the proposed repository at Yucca Mountain. This determination was conservatively based on limited knowledge of the potential activities ongoing on or off the Nevada Test Site (NTS). It is intended that the Industrial/Military Activity-Initiated Accident Screening Analysis provided herein will meet the requirements of the ''Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants'' (NRC 1987) in establishing whether this external event can be screened from further consideration or must be included as a design basis event (DBE) in the development of accident scenarios for the Monitored Geologic Repository (MGR). This analysis only considers issues related to preclosure radiological safety. Issues important to waste isolation as related to impact from nearby installations will be covered in the MGR performance assessment.

  6. Target aligned heliostat field layout for non-flat terrrain

    CSIR Research Space (South Africa)

    Buck, R

    2012-05-01

    Full Text Available The layout for a solar tower test facility for CSIR, Pretoria, is described. The solar tower system is designed for 400kWth receiver outlet power. The heliostat field layout takes into account both the real (non-flat) topography of the terrain...

  7. Molecular activation analysis for chemical species studies

    International Nuclear Information System (INIS)

    Chai Zhifang; Mao Xueying; Wang Yuqi; Sun Jingxin; Qian Qingfang; Hou Xiaolin; Zhang Peiqun; Chen Chunying; Feng Weiyu; Ding Wenjun; Li Xiaolin; Li Chunsheng; Dai Xiongxin

    2001-01-01

    The Molecular Activation Analysis (MAA) mainly refers to an activation analysis method that is able to provide information about the chemical species of elements in systems of interest, though its exact definition has remained to be assigned. Its development is strongly stimulated by the urgent need to know the chemical species of elements, because the bulk contents or concentrations are often insignificant for judging biological, environmental or geochemical effects of elements. In this paper, the features, methodology and limitation of MAA were outlined. Further, the up-to-date MAA progress made in our laboratory was introduced as well. (author)

  8. Recent applications of neutron activation analysis at Lucas Heights

    International Nuclear Information System (INIS)

    Fardy, J.J.

    1978-01-01

    The use of neutron activation analysis to determine key elemental distribution patterns in samples from both the energy industry and health science field is summarised. Instrumental neutron activation analysis has successfully measured simultaneously more than twenty elements in a sample of brown coal from Victoria, black coal from New South Wales and samples from the product stream of ACIRL's batch autoclave, solvent-refined, coal hydrogenation process. Four gallstones removed from the same gallbladder have been examined instrumentally by neutron activation analysis. A total of sixteen trace elements were detected with concentrations in the range 0.8 ng g -1 for gold to 7,800 μg g -1 for calcium

  9. Proton activation analysis at the Harvard Cyclotron Laboratory

    International Nuclear Information System (INIS)

    Sisterson, J.M.; Koehler, A.M.

    1984-01-01

    High-energy proton activation analysis (PAA), a simple non-destructive technique, has been developed for use as an adjunct to neutron activation analysis. Potential advantages of protons include the ability to achieve very precise localization of the activation volume over a pre-determined depth in the target. To demonstrate the versatility of PAA, results are reported on the measurement of the whole body calcium content in animals and on the determination of the Ca/P molar ratio in small quantities (<50 mg) of chemical and biological samples. The animal experiments demonstrate the ability to achieve a uniform irradiation over a large volume and utilizes large NaI crystals with a special chamber for uniform combined detection efficiency, where the Ca/P molar ratio determination requires a Ge/Li detector and analysis of the resulting gamma ray spectrum. The feasibility is being assessed of using proton beam activation of the eye to measure blood flow in the rabbit choroid, based on earlier work where it was used to measure blood in mouse skeletal tissue. 6 references, 7 figures, 4 tables

  10. Conceptual design tool development for a Pb-Bi cooled reactor

    International Nuclear Information System (INIS)

    Lee, K. G.; Chang, S. H.; No, H. C.; Chunm, M. H.

    2000-01-01

    Conceptual design is generally ill-structured and mysterious problem solving. This leads the experienced experts to be still responsible for the most of synthesis and analysis task, which are not amenable to logical formulations in design problems. Especially because a novel reactor such as a Pb-Bi cooled reactor is going on a conceptual design stage, it will be very meaningful to develop the conceptual design tool. This tool consists of system design module with artificial intelligence, scaling module, and validation module. System design decides the optimal structure and the layout of a Pb-Bi cooled reactor, using design synthesis part and design analysis part. The designed system is scaled to be optimal with desired power level, and then the design basis accidents (Dbase) are analyzed in validation module. Design synthesis part contains the specific data for reactor components and the general data for a Pb-Bi cooled reactor. Design analysis part contains several design constraints for formulation and solution of a design problem. In addition, designer's intention may be externalized through emphasis on design requirements. For the purpose of demonstration, the conceptual design tool is applied to a Pb-Bi cooled reactor with 125 M Wth of power level. The Pb-Bi cooled reactor is a novel reactor concept in which the fission-generated heat is transferred from the primary coolant to the secondary coolant through a reactor vessel wall of a novel design. The Pb-Bi cooled reactor is to deliver 125 M Wth per module for 15 effective full power years without any on-site fuel handling. The conceptual design tool investigated the feasibility of a Pb-Bi cooled reactor. Application of the conceptual design tool will be, in detail, presented in the full paper. (author)

  11. Activation analysis by filtered neutrons. Preliminary investigation

    International Nuclear Information System (INIS)

    Skarnemark, G.; Rodinson, T.; Skaalberg, M.; Tokay, R.K.

    1986-01-01

    In order to investigate if measuring sensibility and precision by epithermal neutron activation analysis may be improved, different types of geological and biologic test samples were radiated. The test samples were enclosed in an extra filter of tungsten or sodium in order to reduce the flux of those neutrons that otherwise would induce interfering activity in the sample. The geological test samples consist of granites containing lanthanides which had been crushed in tung- sten carbide grinder. Normally such test samples show a interferins 1 87W-activity. By use of a tungsten filter the activity was reduced by up to 60%, which resulted in a considerable improvement of sensibility and precision of the measurement. The biologic test samples consisted of evaporated urine from patients treated with the cell poison cis-platinol. A reliable method to measure the platinum content has not existed so far. This method, however, enables platinum contents as low as about 0.1 ppm to be determined which is quite adequate. To sum up this preliminary study has demonstrated that activation analysis using filtered neutrons, correctly applied, is a satisfactory method of reducing interferences without complicated and time-consuming chemical separation procedures. (O.S.)

  12. US--ITER activation analysis

    International Nuclear Information System (INIS)

    Attaya, H.; Gohar, Y.; Smith, D.

    1990-09-01

    Activation analysis has been made for the US ITER design. The radioactivity and the decay heat have been calculated, during operation and after shutdown for the two ITER phases, the Physics Phase and the Technology Phase. The Physics Phase operates about 24 full power days (FPDs) at fusion power level of 1100 MW and the Technology Phase has 860 MW fusion power and operates for about 1360 FPDs. The point-wise gamma sources have been calculated everywhere in the reactor at several times after shutdown of the two phases and are then used to calculate the biological dose everywhere in the reactor. Activation calculations have been made also for ITER divertor. The results are presented for different continuous operation times and for only one pulse. The effect of the pulsed operation on the radioactivity is analyzed. 6 refs., 12 figs., 1 tab

  13. Applications of neutron activation analysis in industry

    International Nuclear Information System (INIS)

    Zaini Hamzah.

    1985-01-01

    Neutron activation analysis technique is discussed in brief. This technique is used for quality control of raw materials, process materials and finished products, as well as activities in research and development for the improvement of the products and new products. The uses of this technique in several experienced industries are mentioned (author)

  14. Development of neutron activation analysis software

    International Nuclear Information System (INIS)

    Wang Liyu

    1987-10-01

    The software for quantitative neutron activation analysis was developed to run under the MS/DOS operating system. The programmes of the IBM/SPAN include: spectra file transfer from and to a Canberra Series 35 multichannel analyzer, spectrum evaluation routines, calibration subprogrammes, and quantitative analysis. The programmes for spectrum analysis include fitting routine for separation of multiple lines by reproducing the peak shape with a combination of Gaussian and exponential terms. The programmes were tested on an IBM/AT-compatible computer. The programmes and the sources are available costfree for the IAEA projects of Technical Cooperation. 7 refs, 3 figs

  15. Proceedings of the specialist research meeting on 'the latest study on analysis of trace amount of elements using activation analysis and the results and future prospects of activation analysis using KUR'

    International Nuclear Information System (INIS)

    Ebihara, Mitsuru; Shibata, Seiichi; Sekimoto, Shun

    2014-01-01

    This Specialist Research Meeting report is the summary of the lectures that were delivered at the Specialist Research Meeting of Kyoto University Reactor Research Institute on January 25, 2013 and October 30, 2013. These meetings were held under the subtitles of 'Current state of trace element analysis using activation analysis' and 'Achievements and future prospects of activation analysis using Kyoto University research reactor (KUR)', respectively. At the former meeting, 14 speeches were delivered including the following: (1) introduction of Australia Nuclear Science and Technology Organisation (ANSTO), (2) determination of element concentration in the hairs in frequent ALS (amyotrophic lateral sclerosis) occurrence zones, (3) effects of vegetation on the acid neutralizing capacity of soil, (4) activation analysis of geological samples, and (5) current situation of KUR. At the latter meeting, 15 speeches were delivered including the following: (1) neutron activation analysis of iron meteorites and Chinese herbal medicines / herbs, (2) neutron activation analysis at KUR using IAEA-k0 method, (3) current state of KUR, (4) development and applications of automatic prompt gamma-ray analysis equipment. (A.O.)

  16. Ultrasonic features and radionuclide correlation in liver cell adenoma and focal nodular hyperplasia

    International Nuclear Information System (INIS)

    Sandler, M.A.; Petrocelli, R.D.; Marks, D.S.; Lopez, R.

    1980-01-01

    Ultrasonic features of three cases of liver cell adenoma (LCA) and two cases of focal nodular hyperplasia (FNH) are presented. These tumors have similar sonographic appearances presenting either as solid masses or containing sonolucent areas due to hemorrhage or necrosis. Although these ultrasonic features in patients wth an area of decreased activity on /sup 99m/Tc-sulfur colloid (Tc-SC) liver scans are not specific for LCA or FNH, such findings in the appropriate clinical setting are suggestive of these lesions. The combination of a solid mass on ultrasonography and a normal Tc-SC radioisotope liver study may be relatively specific for uncomplicated FNH

  17. Ultrasonic features and radionuclide correlation in liver cell adenoma and focal nodular hyperplasia. [/sub 99m/Tc-sulfur colloid; /sup 131/I-rose bengal; /sup 67/Ga-citrate

    Energy Technology Data Exchange (ETDEWEB)

    Sandler, M.A.; Petrocelli, R.D.; Marks, D.S.; Lopez, R.

    1980-05-01

    Ultrasonic features of three cases of liver cell adenoma (LCA) and two cases of focal nodular hyperplasia (FNH) are presented. These tumors have similar sonographic appearances presenting either as solid masses or containing sonolucent areas due to hemorrhage or necrosis. Although these ultrasonic features in patients wth an area of decreased activity on /sup 99m/Tc-sulfur colloid (Tc-SC) liver scans are not specific for LCA or FNH, such findings in the appropriate clinical setting are suggestive of these lesions. The combination of a solid mass on ultrasonography and a normal Tc-SC radioisotope liver study may be relatively specific for uncomplicated FNH.

  18. Prompt gamma-ray activation analysis (PGAA)

    International Nuclear Information System (INIS)

    Kern, J.

    1996-01-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs

  19. Prompt gamma-ray activation analysis (PGAA)

    Energy Technology Data Exchange (ETDEWEB)

    Kern, J [Fribourg Univ. (Switzerland). Inst. de Physique

    1996-11-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs.

  20. International conference activation analysis and its applications (ICAAA): abstracts

    International Nuclear Information System (INIS)

    1990-01-01

    International conference on the Activation Analysis and its Applications was hold in Beijing of China on October 15-19, 1990. It was organized and co-sponsored by Division of Activation Analysis and Radioanalysis, National Natural Science Foundation of China and China Nuclear Society, etc.. 159 pieces of Articles in the field were received in the conference, from many countries

  1. Design and testing of a heat pipe gas combustion system for the STM4-120 Stirling engine

    Science.gov (United States)

    Khalili, K.; Godett, T. M.; Meijer, R. J.; Verhey, R. P.

    Evaporators of a novel geometry, designed to have a more compact size yet the same output as larger, conventional heat pipes, have been fabricated and tested. A technique was developed to calculate capillary pressure required inside the heat pipe. Several quarter- and full-scale evaporators were designed and successfully tested. The burner, film-cooled combustion chamber, and preheater were designed and tested separately. A complete heat pipe gas combustion system (HPGC) was tested, showing an efficiency of 89 percent was measured at 20 kWth. A film-cooled combustion chamber was tested with flame temperatures of 2200 C and wall temperatures below 1000 C using preheated air for film cooling. Also, a full-scale HPGC was tested at an excess of 95 kWth, showing efficiency in the range of 85 to 90 percent under steady-state conditions. Results of transient and startup tests, carried out to evaluate the performance of the heat pipe, all also reported.

  2. Instrumental activation analysis of molybdenites

    International Nuclear Information System (INIS)

    Geisler, M.; Schelhorn, H.

    1981-01-01

    Na, K, Sc, Cr, Fe, Co, Se, Rb, Ag, Cs, Ba, La, Ce, Eu, Yb, Hf, W, Re, and Th have been determined in 6 molybdenite samples by instrumental activation analysis. The samples were of different origin and showed K, Sc, W, and Re values with differences of more than two orders of magnitude, whereas Sc values were within one order of magnitude

  3. The verification of neutron activation analysis support system (cooperative research)

    Energy Technology Data Exchange (ETDEWEB)

    Sasajima, Fumio; Ichimura, Shigeju; Ohtomo, Akitoshi; Takayanagi, Masaji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Sawahata, Hiroyuki; Ito, Yasuo [Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology; Onizawa, Kouji [Radiation Application Development Association, Tokai, Ibaraki (Japan)

    2000-12-01

    Neutron activation analysis support system is the system in which even the user who has not much experience in the neutron activation analysis can conveniently and accurately carry out the multi-element analysis of the sample. In this verification test, subjects such functions, usability, precision and accuracy of the analysis and etc. of the neutron activation analysis support system were confirmed. As a method of the verification test, it was carried out using irradiation device, measuring device, automatic sample changer and analyzer equipped in the JRR-3M PN-3 facility, and analysis software KAYZERO/SOLCOI based on the k{sub 0} method. With these equipments, calibration of the germanium detector, measurement of the parameter of the irradiation field and analysis of three kinds of environmental standard sample were carried out. The k{sub 0} method adopted in this system is primarily utilized in Europe recently, and it is the analysis method, which can conveniently and accurately carried out the multi-element analysis of the sample without requiring individual comparison standard sample. By this system, total 28 elements were determined quantitatively, and 16 elements with the value guaranteed as analytical data of the NIST (National Institute of Standards and Technology) environment standard sample were analyzed in the accuracy within 15%. This report describes content and verification result of neutron activation support system. (author)

  4. Activation analysis for the IFF system in RAON facility

    International Nuclear Information System (INIS)

    LEE, Cheol Woo; LEE, Young-Ouk; KIM, Jong Won; KIM, Mijung

    2014-01-01

    A heavy-ion accelerator facility is under a development in Korea to use in the basic science research and various application areas. In this facility, the In-Flight Fragment (IFF) target and isotope separator has been designed to produce various isotopes and transport the interesting isotopes into the experimental rooms. In this work, activation analysis for the pre-separator was performed in the IFF target room. In this work, activation analysis for the pre-separator was performed for the IFF target system in RAON heavy-ion accelerator facility. At first, radiation source terms were evaluated with the primary beams and target conditions. Using the evaluated source terms, induced activities in all component of pre-separator were calculated. The decay gamma-rays produced after a shutdown was estimated based on the activation analysis and gamma-ray dose rate according to the cooling time was evaluated

  5. A program for activation analysis data processing

    International Nuclear Information System (INIS)

    Janczyszyn, J.; Loska, L.; Taczanowski, S.

    1978-01-01

    An ALGOL program for activation analysis data handling is presented. The program may be used either for single channel spectrometry data or for multichannel spectrometry. The calculation of instrumental error and of analysis standard deviation is carried out. The outliers are tested, and the regression line diagram with the related observations are plotted by the program. (author)

  6. The analysis and handling concept of minor actinides of NPP’s waste by using Ads technology

    International Nuclear Information System (INIS)

    Silakhuddin

    2008-01-01

    The contents of minor actinide elements (americium, neptunium and curium) on the spent fuel inventory from PWR operation of NPP have been calculated using Vista program. The calculation used parameters: enrichment 3.968%, power 1000 M We and burn-up is 60 M Wd/kg. The result of calculation showed that the arising of minor actinide elements on the spent fuel is 16.205 kg/year and 43.471 kg/year for PWR-UOX and PWR-MOX respectively. It is also discussed a concept of the use of ADS technology for transmuting the minor actinide elements contained in spent fuels. The result of the discussion showed that an ADS of 400 M Wth will serve 7 PWRs-UOX, and on the PWR system using UOX and MOX fuels an ADS will serve 3 PWRs. (author)

  7. General principles of neutron activation analysis

    International Nuclear Information System (INIS)

    Dostal, J.; Elson, C.

    1980-01-01

    Aspects of the principles of atomic and nuclear structure and the processes of radioactivity, nuclear transformation, and the interaction of radiations with matter which are of direct relevance to neutron activation analysis and its application to geologic materials are discussed. (L.L.)

  8. Computer-automated neutron activation analysis system

    International Nuclear Information System (INIS)

    Minor, M.M.; Garcia, S.R.

    1983-01-01

    An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day. 5 references

  9. Activation analysis in the Americas: recent and future perspectives

    International Nuclear Information System (INIS)

    Guinn, V.P.

    1984-01-01

    A total of 243 publications in the field of nuclear activation analysis and its applications during the period of 1977 through mid-1983, from laboratories in North, Central, and South America were reviewed. Various aspects of these populations are treated statistically, for indication of trends, and 146 of these are cited as publications that illustrate the extent of usage of various special forms of the nuclear activation analysis method (e.g., cyclic INAA, prompt-gamma INAA, epithermal NAA, the delayed-neutron method, the use of pre-irradiation chemical separations, etc.) - or that illustrate applications in such fields as archaeology, geochemistry, environmental chemistry, medicine, industry, and forensic chemistry. The overall conclusion is that the method of nuclear activation analysis continues to flourish in this region

  10. Neutron Activation Analysis with k0 standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    1998-01-01

    The objectives of the research are: (1) to develop and implement the k0 standardisation method for neutron activation analysis in close collaboration with scientific partners; (2) to exploit fully the inherent qualities of NAA such as accuracy, traceability, and multi-element offer complete services in health-physics measurements according to international quality standards, (2) to improve continuously these measurement techniques and to follow up international recommendations and legislation concerning the surveillance of workers; (3) to support and advise nuclear and non-nuclear industry on problems of radioactive contamination. Achievements in 1997 related to gamma spectrometry, whole-body counting, beta and alpha spectrometry, dosimetry, radon measurements, calibration, instrumentation, and neutron activation analysis are described

  11. Socio-Economic Impact Of Onchocerciasis With Particular ...

    African Journals Online (AJOL)

    The socio-economic impact of onchocerciasis (river blindness) on humans is reviewed with special reference to females and children. The results of many studies reveal that onchocerciasis is usuallya serious threat to public health and an impediment to socio-economic development in areas wth high intensity and high ...

  12. Measurement and Modeling of Particle Radiation in Coal Flames

    DEFF Research Database (Denmark)

    Bäckström, Daniel; Johansson, Robert; Andersson, Klas Jerker

    2014-01-01

    This work aims at developing a methodology that can provide information of in-flame particle radiation in industrial-scale flames. The method is based on a combination of experimental and modeling work. The experiments have been performed in the high-temperature zone of a 77 kWth swirling lignite...

  13. Natural gold composition studied by proton activation analysis (PAA)

    International Nuclear Information System (INIS)

    Cojocaru, V.; Badica, T.; Popescu, I.V.

    2003-01-01

    The minor and trace element concentration of natural gold is essential for provenance studies of gold archaeological artifacts. In this work proton activation analysis is used in order to find what elements can be put into evidence in natural gold. For that purpose some gold nuggets from Romania were used. It was found that PAA is a good supplemental method to neutron activation analysis. (authors)

  14. Speciation analysis of cobalt in foods by high-performance liquid chromatography and neutron activation analysis

    International Nuclear Information System (INIS)

    Muto, Toshio; Koyama, Motoko

    1994-01-01

    A combined method by coupling high-performance liquid chromatography (HPLC, as a separation method) with neutron activation analysis (as a detection method) have been applied to the speciation analysis of cobalt in daily foods (e.g. egg, fish and milk). Cobalt species including free cobalt, vitamin B 12 and protein-bound cobalt were separated with a preparative HPLC and a centrifuge. Subsequently, the determination of cobalt in the separated species was made by neutron activation analysis. The results showed that the content of the total cobalt in the foods was found to lie in the range 0.4-11ng/g(0.4-11ppb) based on wet weight. The compositions of free cobalt, vitamin B 12 and protein-bound cobalt were ranged 16-43%, 55-73%, 2.3-17%, respectively. These experimental evidences suggest that the combination of HPLC and neutron activation analysis is expected to be a useful tool for speciation analysis of trace elements in biological as well as environmental materials. (author)

  15. Neutronic activation analysis of antique ceramics. Groups and differenciation

    International Nuclear Information System (INIS)

    Widemann, F.

    1975-01-01

    Different techniques for clay analysis in view of studying the origin of ceramics are exposed. The element abundance is measured by X-ray fluorescence analysis or by neutron activation analysis. Comparative tables of the results are established [fr

  16. Using Porterian Activity Analysis to Understand Organizational Capabilities

    DEFF Research Database (Denmark)

    Sheehan, Norman T.; Foss, Nicolai Juul

    2017-01-01

    conceptualized by Porter’s writings on the activity-based view. Porterian activity analysis is becoming more accepted in the strategy literature, but no strategy scholar has explicitly used Porter’s activities, and particularly his concept of drivers, to understand and analyze organizational capabilities....... Introducing Porterian activities into the discussion of capabilities improves strategy scholars’ understanding of the bases of capability heterogeneity, offers academics future directions for research, and provides managers with guidance to enhance their organizations’ capabilities....

  17. Limits of detection in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guinn, V.P.

    1990-01-01

    Lower limits of detection (LLODs), frequently referred to simply as limits of detection and abbreviated as LODs, often appear in the literature of analytical chemistry - for numerous different methods of elemental and/or molecular analysis. In this chapter, one particular method of quantitative elemental analysis, that of instrumental neutron activation analysis (INAA), is the subject discussed, with reference to LODs. Particularly in the literature of neutron activation analysis (NAA), many tables of 'interference-free' NAA LODs are available. Not all of these are of much use, because (1) for many the definition used for LOD is not clear, or reasonable, (2) for many, the analysis conditions used are not clearly specified, and (3) for many, the analysis conditions used are specified, but not very practicable for most laboratories. For NAA work, such tables of interference-free LODs are, in any case, only applicable to samples in which, at the time of counting, only one radionuclide is present to any significant extent in the activated sample. It is important to note that tables of INAA LODs, per se, do not exist - since the LOD for a given element, under stated analysis conditions, can vary by orders of magnitude, depending on the elemental composition of the matrix in which it is present. For any given element, its INAA LOD will always be as large as, and usually much larger than, its tabulated 'interference-free' NAA LOD - how much larger depending upon the elemental composition of the matrix in which it is present. As discussed in this chapter, however, an INAA computer program exists that can calculate realistic INAA LODs for any elements of interest, in any kind of specified sample matrix, under any given set of analysis conditions

  18. Phytochemical analysis and antioxidant activities of Combretum ...

    African Journals Online (AJOL)

    Phytochemical analysis and antioxidant activities of Combretum molle and Pericopsis laxiflora. Kossi-Kuma Agbalevon Koevi, Vinsoun Millogo, Jean Baptiste Hzounda Fokou, Abdou Sarr, Georges Anicet Ouedraogo, Emmanuel Bassene ...

  19. Use of gamma spectroscopy in activation analysis; Utilisation de la spectrographie gamma dans l'analyse par activation

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Brief review of the principles of activation analysis: calculation of activities, decay curves, {beta} absorption curves, examples of application. - Principle and description of the {gamma} spectrograph. - Practical utilisation of the {gamma} spectrograph: analysis by activation, analysis by {beta} - x fluorescence. - Sensitivity limit of the method and precision of the measurements. - Possible improvements to the method: {gamma} spectroscopy with elimination of the Compton effect. (author) [French] Bref rappel des principes de l'analyse par activation: calcul des activites, courbes de decroissance, courbes d'absorption {beta}, exemples d'utilisation. - Principe et description du spectrographe {gamma}. - Utilisation pratique de la spectrographie {gamma}: analyse par activation, analyse par fluorescence {beta} - x. - Limite de sensibilite de la methode et precision des mesures. - Ameliorations possibles de la methode: spectrographe {gamma} avec elimination de l'effet Compton. (auteur)

  20. Betatron activation analysis of cupriferous flotation pulp

    International Nuclear Information System (INIS)

    Kaminski, R.; Matenko, J.; Mencel, J.; Janiczek, J.; Kielsznia, J.

    1974-01-01

    A method of copper determination in cupriferous flotation pulp by photo-activation analysis using betatron and another equipments of existent ''analytical line'' intended for copper determination in dry samples has been described. An activation has been achieved with 14.9 MeV γ-photons. The excitation activity was investigated by using two scintillation detectors and a fast coincidence circuit with resolution time 80 ns. The precision of method was determined as +- 4.25% in 0.95 confidence level for pulp with concentration 5% Cu and +- 24% for 0.06% Cu. (author)

  1. Recurrence analysis of ant activity patterns.

    Directory of Open Access Journals (Sweden)

    Felipe Marcel Neves

    Full Text Available In this study, we used recurrence quantification analysis (RQA and recurrence plots (RPs to compare the movement activity of individual workers of three ant species, as well as a gregarious beetle species. RQA and RPs quantify the number and duration of recurrences of a dynamical system, including a detailed quantification of signals that could be stochastic, deterministic, or both. First, we found substantial differences between the activity dynamics of beetles and ants, with the results suggesting that the beetles have quasi-periodic dynamics and the ants do not. Second, workers from different ant species varied with respect to their dynamics, presenting degrees of predictability as well as stochastic signals. Finally, differences were found among minor and major caste of the same (dimorphic ant species. Our results underscore the potential of RQA and RPs in the analysis of complex behavioral patterns, as well as in general inferences on animal behavior and other biological phenomena.

  2. Applications of neutrons for laboratory and industrial activation analysis problems

    International Nuclear Information System (INIS)

    Szabo, Elek; Bakos, Laszlo

    1986-01-01

    This chapter presents some particular applications and case studies of neutrons in activation analysis for research and industrial development purposes. The reactor neutrons have been applied in Hungarian laboratories for semiconductor research, for analysis of geological (lunar) samples, and for a special comparator measurement of samples. Some industrial applications of neutron generator and sealed sources for analytical problems are presented. Finally, prompt neutron activation analysis is outlined briefly. (R.P.)

  3. Quantitative Structure-Activity Relationship Analysis of the ...

    African Journals Online (AJOL)

    Erah

    Quantitative Structure-Activity Relationship Analysis of the Anticonvulsant ... Two types of molecular descriptors, including the 2D autocorrelation ..... It is based on the simulation of natural .... clustering anticonvulsant, antidepressant, and.

  4. Optimizing human activity patterns using global sensitivity analysis.

    Science.gov (United States)

    Fairchild, Geoffrey; Hickmann, Kyle S; Mniszewski, Susan M; Del Valle, Sara Y; Hyman, James M

    2014-12-01

    Implementing realistic activity patterns for a population is crucial for modeling, for example, disease spread, supply and demand, and disaster response. Using the dynamic activity simulation engine, DASim, we generate schedules for a population that capture regular (e.g., working, eating, and sleeping) and irregular activities (e.g., shopping or going to the doctor). We use the sample entropy (SampEn) statistic to quantify a schedule's regularity for a population. We show how to tune an activity's regularity by adjusting SampEn, thereby making it possible to realistically design activities when creating a schedule. The tuning process sets up a computationally intractable high-dimensional optimization problem. To reduce the computational demand, we use Bayesian Gaussian process regression to compute global sensitivity indices and identify the parameters that have the greatest effect on the variance of SampEn. We use the harmony search (HS) global optimization algorithm to locate global optima. Our results show that HS combined with global sensitivity analysis can efficiently tune the SampEn statistic with few search iterations. We demonstrate how global sensitivity analysis can guide statistical emulation and global optimization algorithms to efficiently tune activities and generate realistic activity patterns. Though our tuning methods are applied to dynamic activity schedule generation, they are general and represent a significant step in the direction of automated tuning and optimization of high-dimensional computer simulations.

  5. Diagnosis of mucoviscidosis by neutron activation analysis. Part 1

    International Nuclear Information System (INIS)

    Bellido, Luis F.; Bellido, Alfredo V.

    1997-02-01

    Symptoms pathology, incidence, and gravity of the inherent syndrome called mucoviscidosis, or cystic fibrosis are described in this Part I. The analytical methods used for its diagnosis, both the conventional chemical ones and by neutron activation analysis are also summarised. Finally, an analytical method to study the incidence of mucoviscidosis in Brazil is presented. This , essentially, consists in bromine determination, in fingernails, by resonance neutron activation analysis. (author)

  6. Neutron Activation analysis of waste water

    International Nuclear Information System (INIS)

    Hernandez H, V.

    1997-01-01

    An instrumental neutron activation analysis for the simultaneous determination of chlorine, bromine, sodium, manganese, cobalt, copper, chromium, zinc, nickel, antimony and iron in waste water is described. They were determined in waste water samples under normal conditions by non-destructive neutron activation simultaneously using a suitable monostandard method. Standardized water samples were used and irradiated in polyethylene ampoules at a neutron flux of 10 13 cm -2 s -1 for periods of 1 minute, 1 and 10 hours. A Ge hyperpure detector was used for your activity determination, with count times of 60, 180, 300 and 600 seconds. The obtained results show than the method can be utilized for the determination of this elements without realize anything previous treatment of the samples. (Author)

  7. Service activities of chemical analysis division

    International Nuclear Information System (INIS)

    Eom, Tae Yoon; Suh, Moo Yul; Park, Kyoung Kyun; Jung, Ki Suk; Joe, Kih Soo; Jee, Kwang Yong; Jung, Woo Sik; Sohn, Se Chul; Yeo, In Heong; Han, Sun Ho

    1988-12-01

    Progress of the Division during the year of 1988 was described on the service activities for various R and D projects carrying out in the Institute, for the fuel fabrication and conversion plant, and for the post-irradiation examination facility. Relevant analytical methodologies developed for the chemical analysis of an irradiated fuel, safeguards chemical analysis, and pool water monitoring were included such as chromatographic separation of lanthanides, polarographic determination of dissolved oxygen in water, and automation on potentiometric titration of uranium. Some of the laboratory manuals revised were also included in this progress report. (Author)

  8. Application of nuclear activation analysis

    International Nuclear Information System (INIS)

    Mamonov, E.I.; Khlystova, A.F.

    1979-01-01

    Consideration is given to the applications of nuclear-activation analysis (NAA) as discussed at the International Conference of 1977. One of the new results in the present-day NAA practices is the growing number of elements detected in samples without using a destructive radiochemical separation. An essential feature in this context is the development of the system automation of control and information NAA operations through the use computers. In biological medicine a multicomponent NAA is employed to determine the concentration of elements in various human organs and objects, in metabolic studies and for diagnostic purposes. In agriculture NAA finds applications in the evaluation of grain protein, analysis of element feed composition, soil and fertilizers. The application of this method to the environmental monitoring is considered with particular reference to the element analysis of water (especially drinking water), air, plant residues. Data are presented for the use of NAA in metallurgy, geology, archaeology and criminal law. Tables are provided to illustrate the uses of NAA in various fields

  9. Epithermal neutron activation analysis for studying the environment

    International Nuclear Information System (INIS)

    Frontas'eva, M.V.; Steinnes, E.

    1997-01-01

    Epithermal neutron activation analysis (ENAA) has certain advantages over the conventional instrumental analysis (INAA) in terms of improvement in precision and lowering of detection limits, reduction of high matrix activity and fission interferences if any. The current status and the applications of ENAA to environmental samples are reviewed. Experience in the use of ENAA in the monitoring of atmospheric depositions by means of moss-biomonitors at pulsed fast reactor IBR-2 in Dubna is summarized. INAA has shown to be useful for a number of sample types of interest in environmental studies, and should find more extensive use in this area. Analysis of airborne particulate matter is a case where ENAA should be particularly useful. A similar case where ENAA has shown strong performance is in the analysis of mosses used as biomonitors of atmospheric deposition, where 45 elements were determined. In this and other cases, however, induction-coupled plasma mass spectrometry is a very strong competitor, offering data for even more elements. A comparison of ENAA and ICP-MS for moss analysis is presented, and cases where ENAA is unique are discussed

  10. Applications of neutron activation analysis in environmental science, biology and geoscience

    International Nuclear Information System (INIS)

    1992-01-01

    The applications of neutron activation analysis technique with high sensitivity, good accuracy, multielemental analysis and non-destruction of samples in hydrosphere, soil and lithosphere, atmosphere, cosmosphere and biosphere were introduced in this book. A large amount of research activities in this field during the 20 years and more carried out by Neutron Activation Analysis Laboratory, Institute of High Energy Physics, Academia Sinica, was summarized. A number of the data and information with important scientific significance was provided

  11. Studies on the environmental implications of ants (Hymenoptera ...

    African Journals Online (AJOL)

    A study of ants associated wh two synanthropcenvironments in Awka was carried out in 2008 using pitfall and bait traps. The study yelded a total of 561 ants wth 409 obtaned from the hemisynanthrophic environment while 192 ants were collected from the endophilic environment. The percentage occurrence, total dstribution ...

  12. Depression and Anorexia Nervosa of Persons with Down Syndrome.

    Science.gov (United States)

    Szymanski, Ludwik S.; Biederman, Joseph

    1984-01-01

    Manifestations of depression in three adults wth Down syndrome, one of whom also exhibited anorexia nervosa, are described. Overall findings indicate that major depression in Down syndrome may be more frequent than previously assumed and that it can be diagnosed with standard diagnostic criteria, modified according to the patient's developmental…

  13. Prevalence of Fasciola gigantica, Cysticercus bovis and some other ...

    African Journals Online (AJOL)

    Other disease conditions seen were splenomegaly, jaundice, and telangiactasis. Out of the 150cattle examined, 30 (20%) were infected or have disease. A total of 150 cattle comprising 116 males and 34 females were examined. The distribution of infections is as follows: 1(070%) was infected wth Cysticercus bovis, ...

  14. Performance response and egg qualities of laying birds fed enzyme ...

    African Journals Online (AJOL)

    Theperformance response and egg qualities o laying birds fed enzyme supplemented PKC diets asreplacement for maize was investigated wth 210, 20 week old layng pullets of Dominant Black strain at the Teaching and Research Farm of the Delta State University, Asaba Campus, Nigeria. The birds which ust come into ...

  15. Fast neutron activation analysis of Kalewa (Myanmar) coal

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Naing, W [Yangon Univ. (Myanmar). Dept. of Chemistry

    1994-06-01

    Aluminium, silicon, copper, iron, magnesium and sulfur in Kalewa (Myanmar) coal were determined by fast neutron activation analysis. For activation a KAMAN A-710 Neutron Generator was used. Kalewa coal was found to be low in sulfur and relatively rich in iron. (author) 2 refs.; 1 fig.; 1 tab.

  16. Fast neutron activation analysis of Kalewa (Myanmar) coal

    International Nuclear Information System (INIS)

    Myint, U.; Naing, W.

    1994-01-01

    Aluminium, silicon, copper, iron, magnesium and sulfur in Kalewa (Myanmar) coal were determined by fast neutron activation analysis. For activation a KAMAN A-710 Neutron Generator was used. Kalewa coal was found to be low in sulfur and relatively rich in iron. (author) 2 refs.; 1 fig.; 1 tab

  17. Molecular activation analysis for chemical speciation studies

    International Nuclear Information System (INIS)

    Chai-Chifang

    1998-01-01

    The term of Molecular Activation Analysis (MAA) refers to an activation analysis method that is able to provide information about the chemical species of elements in system of interests, though its definition has remained to be assigned. Its development is strongly stimulated by the urgent need to know the chemical species of elements, because the total concentrations are often without any meaning when assessing health or environmental risks of trace elements.In practice, the MAA is a combination of conventional instrumental or radiochemical activation analysis and physical, chemical or biochemical separation techniques. The MAA is able to play a particular role in speciation studies. However, the critical point in the MAA is that it is not permitted to change the primitive chemical species of elements in systems, or the change has to be under control; in the meantime it is not allowed to form the 'new artifact' originally not present in systems. Some practical examples of MAA for chemical species research performed recently in our laboratory will be presented as follows: Chemical species of platinum group elements in sediment; Chemical species of iodine in marine algae; Chemical species of mercury in human tissues; Chemical species of selenium in corn; Chemical species of rare earth elements in natural plant, etc. The merits and limitations of MAA will be described as well. (author)

  18. Activation Analysis and Public Health. Survey Paper

    Energy Technology Data Exchange (ETDEWEB)

    Lenihan, I. M.A. [Western Regional Hospital Board, Glasgow (United Kingdom); Smith, H. [University of Glasgow, Glasgow (United Kingdom)

    1967-10-15

    The technique of activation analysis has useful and distinctive applications, not yet fully recognized or exploited, in public health. Three areas of usefulness may be recognized. 1. Industrial hygiene. Activation analysis offers a simple and efficient method for assessing and controlling occupational hazards associated with the handling of toxic materials, such as compounds of arsenic and of mercury. Examination of hair and nail samples, taken at six-monthly intervals, will yield a surprising amount of information regarding the influence on occupational exposure of individual variation in working habits, and inadequacy or non-observance of hygienic rules and other prescribed safety measures. 2. Epidemiology. The advantage conferred by activation analysis lies in the possibility of rapid and accurate estimation of trace element concentrations in small samples of tissue or other materials, such as can readily be obtained from population groups large enough to be statistically significant. Surveys of this kind have interesting potentialities in relation to dental caries, cancer, cirrhosis of the liver and heart disease. 3. Recognition of essential trace elements. Surveys of trace element concentrations suggest that the variability of tissue levels among members of a population is smaller for essential trace elements than for non-essential elements. It is possible also that tissue levels show a normal distribution for essential elements and a log-normal distribution for non-essential elements. (author)

  19. Neutron activation analysis: an emerging technique for conservation/preservation

    International Nuclear Information System (INIS)

    Sayre, E.V.

    1976-01-01

    The diverse applications of neutron activation in analysis, preservation, and documentation of art works and artifacts are described with illustrations for each application. The uses of this technique to solve problems of attribution and authentication, to reveal the inner structure and composition of art objects, and, in some instances to recreate details of the objects are described. A brief discussion of the theory and techniques of neutron activation analysis is also included

  20. Neutron activation analysis of certified samples by the absolute method

    Science.gov (United States)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  1. Limitations for qualitative and quantitative neutron activation analysis using reactor neutrons

    International Nuclear Information System (INIS)

    El-Abbady, W.H.; El-Tanahy, Z.H.; El-Hagg, A.A.; Hassan, A.M.

    1999-01-01

    In this work, the most important limitations for qualitative and quantitative analysis using reactor neutrons for activation are reviewed. Each limitation is discussed using different examples of activated samples. Photopeak estimation, nuclear reactions interference and neutron flux measurements are taken into consideration. Solutions for high accuracy evaluation in neutron activation analysis applications are given. (author)

  2. Systems Studies Department FY 78 activity report. Volume 2. Systems analysis

    International Nuclear Information System (INIS)

    Gold, T.S.

    1979-02-01

    The Systems Studies Department at Sandia Laboratories Livermore (SLL) has two primary responsibilities: to provide computational and mathematical services and to perform systems analysis studies. This document (Volume 2) describes the FY Systems Analysis highlights. The description is an unclassified overview of activities and is not complete or exhaustive. The objective of the systems analysis activities is to evaluate the relative value of alternative concepts and systems. SLL systems analysis activities reflect Sandia Laboratory programs and in 1978 consisted of study efforts in three areas: national security: evaluations of strategic, theater, and navy nuclear weapons issues; energy technology: particularly in support of Sandia's solar thermal programs; and nuclear fuel cycle physical security: a special project conducted for the Nuclear Regulatory Commission. Highlights of these activities are described in the following sections. 7 figures

  3. Nondestructive neutron activation analysis of silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Vandergraaf, T. T.; Wikjord, A. G.

    1973-10-15

    Instrumentel neutron activation analysis was used to determine trace constituents in silicon carbide. Four commercial powders of different origin, an NBS reference material, and a single crystal were characterized. A total of 36 activation species were identified nondestructively by high resolution gamma spectrometry; quantitative results are given for 12 of the more predominant elements. The limitations of the method for certain elements are discussed. Consideration is given to the depression of the neutron flux by impurities with large neutron absorption cross sections. Radiation fields from the various specimens were estimated assuming all radionuclides have reached their saturation activities. (auth)

  4. Conference on instrumental activation analysis IAA 85

    International Nuclear Information System (INIS)

    1985-05-01

    The conference heard 23 papers dealing with the application of activation analysis in environmental control, the preparation of calibration standards, gamma spectroscopy, data processing and with the control of the purity of radiopharmaceuticals. (J.P.)

  5. Meta-analysis of workplace physical activity interventions.

    Science.gov (United States)

    Conn, Vicki S; Hafdahl, Adam R; Cooper, Pamela S; Brown, Lori M; Lusk, Sally L

    2009-10-01

    Most adults do not achieve adequate physical activity levels. Despite the potential benefits of worksite health promotion, no previous comprehensive meta-analysis has summarized health and physical activity behavior outcomes from such programs. This comprehensive meta-analysis integrated the extant wide range of worksite physical activity intervention research. Extensive searching located published and unpublished intervention studies reported from 1969 through 2007. Results were coded from primary studies. Random-effects meta-analytic procedures, including moderator analyses, were completed in 2008. Effects on most variables were substantially heterogeneous because diverse studies were included. Standardized mean difference (d) effect sizes were synthesized across approximately 38,231 subjects. Significantly positive effects were observed for physical activity behavior (0.21); fitness (0.57); lipids (0.13); anthropometric measures (0.08); work attendance (0.19); and job stress (0.33). The significant effect size for diabetes risk (0.98) is less robust given small sample sizes. The mean effect size for fitness corresponds to a difference between treatment minus control subjects' means on VO2max of 3.5 mL/kg/min; for lipids, -0.2 on the ratio of total cholesterol to high-density lipoprotein; and for diabetes risk, -12.6 mg/dL on fasting glucose. These findings document that some workplace physical activity interventions can improve both health and important worksite outcomes. Effects were variable for most outcomes, reflecting the diversity of primary studies. Future primary research should compare interventions to confirm causal relationships and further explore heterogeneity.

  6. Development and simulation of various methods for neutron activation analysis

    International Nuclear Information System (INIS)

    Otgooloi, B.

    1993-01-01

    Simple methods for neutron activation analysis have been developed. The results on the studies of installation for determination of fluorine in fluorite ores directly on the lorry by fast neutron activation analysis have been shown. Nitrogen in organic materials was shown by N 14 and N 15 activation. The description of the new equipment 'FLUORITE' for fluorate factory have been shortly given. Pu and Be isotope in organic materials, including in wheat, was measured. 25 figs, 19 tabs. (Author, Translated by J.U)

  7. Current studies of biological materials using instrumental and radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Fardy, J.J.; McOrist, G.D.; Farrar, Y.J.

    1985-01-01

    Instrumental neutron activation analysis still remains the preferred option when analysing the trace element distribution in a wide rage of materials by neutron activation analysis. However, when lower limits of detection are required or major interferences reduce the effectiveness of this technique, radiochemical neutron activation analysis is applied. This paper examines the current use of both methods and the development of rapid radiochemical techniques for analysis of the biological materials, hair, cow's milk, human's milk, milk powder, blood and blood serum

  8. Combustion performance of pyrolysis oil/ethanol blends in a residential-scale oil-fired boiler

    Science.gov (United States)

    A 40 kWth oil-fired commercial boiler was fueled with blends of biomass pyrolysis oil (py-oil) and ethanol to determine the feasibility of using these blends as a replacement for fuel oil in home heating applications. An optimal set of test parameters was determined for the combustion of these blend...

  9. Neutron activation analysis using TRIGA

    International Nuclear Information System (INIS)

    Byrne, A.R.

    1972-01-01

    Activation analysis with TRIGA MARK II is the main part of the work of the nuclear Chemistry Section at the Institute. A major part of the effort in this field is concerned with the determination of trace elements at the micro and nanogram level in a wide variety of materials, and with the development of new methods, (or the adaptation of known methods,) applicable to these determinations. In particular, specific and group radiochemical separations are studied

  10. Simulation for sodium-24 production using cyclic neutron activation analysis

    International Nuclear Information System (INIS)

    Ahamed, O. M. H.

    2012-04-01

    The cyclic neutron activation analysis is a method for elemental analysis which is preferred to use short-lived radio-nuclides. In recent years this method became a new application for radioisotope production especially in low power research reactors. In this study instrumental cyclic neutron activation analysis was used for 2 4N a production using 2 3N a (n, γ) 2 4N a reaction. The simplified westcott convention method is used neutron activation analysis in a research reactor. The method takes into account all corrections that can affect that yield created. In this work a model was devolving for calculations through this simplified Westcott convention method by using C++ program and selecting good parameters that can produce the expected activity. The simulation is used for the theoretical yield calculated has been validated by data from the 1 77L u production used for theoretical yield which it gives the approached result had been obtained by FORTRAN 90 from literature (8). The results were achieved for expected activity at full power (1 x 10 1 2n cm -2 s - 1 ) and half power (5 x 10 11 cm -2 s -1 ) for research reactor MNSR. The activity at full power was equal to about twice the activity at half power ( 49±7, 24.9 ± MBq/g), respectively. The irradiation parameters selected were irradiation time 4 min and decay time 12 min. Sample weight was 50 mg at 12 numbers of cycles, when the K-factor was equal to 1.74. This work is considered as first step for production of 2 4N a which can use such parameters experimentally. It is then possible to compare the expected activity with measured activity. (Author)

  11. Fast neutron activation analysis by means of low voltage neutron generator

    Directory of Open Access Journals (Sweden)

    M.E. Medhat

    Full Text Available A description of D-T neutron generator (NG is presented. This machine can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. Procedure of neutron flux determination and efficiency calculation is described. Examples of testing some Egyptian natural cosmetics are given. Keywords: Neutron generator, Fast neutron activation analysis, Elemental analysis

  12. Multielement analysis of biological standards by neutron activation analysis

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1977-01-01

    Up to 28 elements were determined in two IAEA standards: Animal Muscle H4 and Fish Soluble A 6/74, and three NBS standards: Spinach: SRM-1570, Tomato Leaves: SRM-1573 and Pine Needles: SRM-1575 by instrumental neutron-activation analysis. Seven noble metals were determined in two NBS standards: Coal: SRM-1632 and Coal Fly Ash: SRM-1633 by radiochemical procedure while 11 rare earth elements were determined in NBS standard Orchard Leaves: SRM-1571 by instrumental neutron-activation analysis. The results are in good agreement with the certified and/or literature data where available. The irradiations were performed at the Cornell TRIGA Mark II nuclear reactor at a thermal neutron flux of 1-3x10 12 ncm -2 sec -1 . The short-lived species were determined after a 2-minute irradiation in the pneumatic rabbit tube, and the longer-lived species after an 8-hour irradiation in the central thimble facility. The standards and samples were counted on coaxial 56-cm 3 Ge(Li) detector. The system resolution was 1.96 keV (FWHM) with a peak to Compton ratio of 37:1 and counting efficiency of 13%, all compared to the 1.332 MeV photopeak of Co-60. (T.I.)

  13. Fast neutron activation analysis in metallurgy

    International Nuclear Information System (INIS)

    Sterlinski, S.

    1981-01-01

    Article discusses the usage of a 14 MeV neutron generator for producing fast neutrons of different energies and intensities. A complete instrumental set-up for the neutron activation analysis (NAA) is given. In metallurgy the device is mainly used in the determination of oxygen and silicon in steel and non-ferrous metal, including different alloys

  14. Neutron activation analysis applied to energy and environment

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1975-01-01

    Neutron activation analysis was applied to a number of problems concerned with energy production and the environment. Burning of fossil fuel, the search for new sources of uranium, possible presence of toxic elements in food and water, and the relationship of trace elements to cardiovascular disease are some of the problems in which neutron activation was used. (auth)

  15. Optimization of time characteristics in activation analysis

    International Nuclear Information System (INIS)

    Gurvich, L.G.; Umaraliev, A.T.

    2006-01-01

    Full text: The activation analysis temporal characteristics optimization methods developed at present are aimed at determination of optimal values of the three important parameters - irradiation time, cooling time and measurement time. In the performed works, especially in [1-5] the activation analysis processes are described, the optimal values of optimization parameters are obtained from equations solved, and the computational results are given for these parameters for a number of elements. However, the equations presented in [2] were inaccurate, did not allow one to have optimization parameters results for one element content calculations, and it did not take into account background dependence of time. Therefore, we proposed modified equations to determine the optimal temporal parameters and iteration processes for the solution of these equations. It is well-known that the activity of studied sample during measurements does not change significantly, i.e. measurement time is much shorter than the half-life, thus the processes taking place can be described by the Poisson probability distribution, and in general case one can apply binomial distribution. The equation and iteration processes use in this research describe both probability distributions. Expectedly, the cooling time iteration expressions obtained for one element analysis case are similar for the both distribution types, as the optimised time values occurred to be of the same order as half-life values, whereas the cooling time, as we observed, depends on the ratio of the studied sample's peak value to the background peak, and can be significantly larger than the half-life value. This pattern is general, and can be derived from the optimized time expressions, which is supported by the experimental data on short-living isotopes [3,4]. For the isotopes with large half-lives, up to years, like cobalt-60, the cooling time values given in the above mentioned works are equal to months which, apparently

  16. Large Sample Neutron Activation Analysis of Heterogeneous Samples

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Vasilopoulou, T.; Tzika, F.

    2018-01-01

    A Large Sample Neutron Activation Analysis (LSNAA) technique was developed for non-destructive analysis of heterogeneous bulk samples. The technique incorporated collimated scanning and combining experimental measurements and Monte Carlo simulations for the identification of inhomogeneities in large volume samples and the correction of their effect on the interpretation of gamma-spectrometry data. Corrections were applied for the effect of neutron self-shielding, gamma-ray attenuation, geometrical factor and heterogeneous activity distribution within the sample. A benchmark experiment was performed to investigate the effect of heterogeneity on the accuracy of LSNAA. Moreover, a ceramic vase was analyzed as a whole demonstrating the feasibility of the technique. The LSNAA results were compared against results obtained by INAA and a satisfactory agreement between the two methods was observed. This study showed that LSNAA is a technique capable to perform accurate non-destructive, multi-elemental compositional analysis of heterogeneous objects. It also revealed the great potential of the technique for the analysis of precious objects and artefacts that need to be preserved intact and cannot be damaged for sampling purposes. (author)

  17. Activation analysis of some seaweeds of Myanmar

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Myint, Aye Myint [Yangon Univ. (Myanmar). Dept. of Chemistry

    1994-11-01

    Activation analysis of some seaweed samples occurring off the coastline areas of Myanmar is described. Na, K and I were determined using Am(Be) radionuclide neutron source and low level [beta]-counting. (author) 3 refs.; 1 fig.; 2 tabs.

  18. Use of activation analysis of hair in environmental protection

    International Nuclear Information System (INIS)

    Obrusnik, I.

    1982-01-01

    Human hair is very suitable for use in environmental control monitoring because trace elements concentrate in it at higher levels than in most other organs. Unlike in other biological materials, the trace element contents in hair can be determined by instrumental neutron activation analysis (INAA), as the interference by 24 Na can be eliminated by appropriate washing of hair, e.g., using the procedure recommended by IAEA. The methods of sampling, washing and sample analysis using INAA and neutron activation analysis with radiochemical separation are described including the recommended way of the presentation of results. The results are presented of analyses for trace elements in hair from both little and highly polluted areas. (Ha)

  19. Pneumatic transport devices based on the ARS equipment set for activation analysis

    International Nuclear Information System (INIS)

    Ivanov, I.V.; Ivanets, V.N.; Rogachev, V.M.; Zakharov, E.A.

    1978-01-01

    The AGIDEL and ARS-28G facilities manufactured on the basis of a set of standardized and aggregated products for activation analysis are described. The AGIDEL is designed for automatic activation analysis of relatively homogeneous samples from oil boreholes. The ARS-28G is designed for transporting the test samples during activation analysis, using a fast-neutron generator. Structurally, the ARS-28 is based on a pneumatic transportation system with two independenhat transport cnnels and a two-channel rotating irradiation unit. The analyzed samples are transported in polyethylene containers, which are moved by compressed air. The facility has been successfully tested and is used in an automated system for multielement activation analysis

  20. Neutron activation analysis

    International Nuclear Information System (INIS)

    Okada, Yukiko

    2005-01-01

    Trends and progress in neutron activation analysis (NAA) for the period starting in 1999 to 2003 are presented. Numbers of published reports on NAA are decreasing year by year as investigated from the database JST and NUCLEN. Summary reports on the international conferences held on NAA are followed by classifying according to the fields: various measurement techniques and application fields. Specially focused topics are newly developed techniques for measuring trace elements with high sensitivity and high accuracy such as (1) by diminishing the Compton-background gamma-rays using anti-coincidence technique, (2) by using prompt-gamma rays measurement method (PGAA) and (3) by using a gamma-ray detector array (GEMINI), which has succeeded in a simultaneous quantification of 27 elements from a standard rock sample having a weight of only 10 milligrams, and others. These techniques will be applied in the space and earth sciences and medical fields. (S. Ohno)

  1. Radiochemical and instrumental neutron activation analysis - recent trends

    International Nuclear Information System (INIS)

    Dams, R.

    1990-01-01

    Recent trends of radiochemical and instrumental neutron activation analysis are discussed. Novel developments include the application of cyclic and pulsed activation, better energy resolution with hyperpure germanium detectors, and use of pulse processing systems allowing extremely high count rates of very short-lived isotopes. Further development is anticipated in the field of speciation in biological and environmental studies. Radiochemical methods have led to accurate determinations at the ng/g level. A promising future is expected for neutron activation techniques. (orig.)

  2. Studies in heavy ion activation analysis Pt. 5

    International Nuclear Information System (INIS)

    Ojo, J.F.; Lass, B.D.; Schweikert, E.A.

    1980-01-01

    Nondestructive heavy ion activation analysis has been used to determine the carbon content in various NBS SRM steel samples with a 7.0 MeV 6 Li + beam. The reaction 12 C( 6 Li,αn) 13 N allows for carbon analysis with the only possible interference being beryllium, 9 Be( 6 Li,2n) 13 N. Under interference-free conditions, and employing a post-irradiation etch, the detection limit for carbon analysis in steel was 5 ppm. (author)

  3. Meta-Analysis of Workplace Physical Activity Interventions

    Science.gov (United States)

    Conn, Vicki S.; Hafdahl, Adam R.; Cooper, Pamela S.; Brown, Lori M.; Lusk, Sally L.

    2009-01-01

    Context Most adults do not achieve adequate physical activity. Despite the potential benefits of worksite health promotion, no previous comprehensive meta-analysis has summarized health and physical activity behavior outcomes from these programs. This comprehensive meta-analysis integrated the extant wide range of worksite physical activity intervention research. Evidence acquisition Extensive searching located published and unpublished intervention studies reported from 1969 through 2007. Results were coded from primary studies. Random-effects meta-analytic procedures, including moderator analyses, were completed in 2008. Evidence synthesis Effects on most variables were substantially heterogeneous because diverse studies were included. Standardized mean difference (d) effect sizes were synthesized across approximately 38,231 subjects. Significantly positive effects were observed for physical activity behavior (0.21), fitness (0.57), lipids (0.13), anthropometric measures (0.08), work attendance (0.19), and job stress (0.33). The significant effect size for diabetes risk (0.98) is more tentative given small sample sizes. Significant heterogeneity documents intervention effects varied across studies. The mean effect size for fitness corresponds to a difference between treatment minus control subjects' means on V02max of 3.5 mL/kg/min; for lipids, −0.2 on total cholesterol:HDL; and for diabetes risk, −12.6 mg/dL on fasting glucose. Conclusions These findings document that some workplace physical activity interventions can improve both health and important worksite outcomes. Effects were variable for most outcomes, reflecting the diversity of primary studies. Future primary research should compare interventions to confirm causal relationships and further explore heterogeneity. PMID:19765506

  4. Hilbert-Huang transform analysis of long-term solar magnetic activity

    Science.gov (United States)

    Deng, Linhua

    2018-04-01

    Astronomical time series analysis is one of the hottest and most important problems, and becomes the suitable way to deal with the underlying dynamical behavior of the considered nonlinear systems. The quasi-periodic analysis of solar magnetic activity has been carried out by various authors during the past fifty years. In this work, the novel Hilbert-Huang transform approach is applied to investigate the yearly numbers of polar faculae in the time interval from 1705 to 1999. The detected periodicities can be allocated to three components: the first one is the short-term variations with periods smaller than 11 years, the second one is the mid- term variations with classical periods from 11 years to 50 years, and the last one is the long-term variations with periods larger than 50 years. The analysis results improve our knowledge on the quasi-periodic variations of solar magnetic activity and could be provided valuable constraints for solar dynamo theory. Furthermore, our analysis results could be useful for understanding the long-term variations of solar magnetic activity, providing crucial information to describe and forecast solar magnetic activity indicators.

  5. A computer program for activation analysis

    International Nuclear Information System (INIS)

    Rantanen, J.; Rosenberg, R.J.

    1983-01-01

    A computer program for calculating the results of activation analysis is described. The program comprises two gamma spectrum analysis programs, STOAV and SAMPO and one program for calculating elemental concentrations, KVANT. STOAV is based on a simple summation of channels and SAMPO is based on fitting of mathematical functions. The programs are tested by analyzing the IAEA G-1 test spectra. In the determination of peak location SAMPO is somewhat better than STOAV and in the determination of peak area SAMPO is more than twice as accurate as STOAV. On the other hand, SAMPO is three times as expensive as STOAV with the use of a Cyber 170 computer. (author)

  6. Quality assurance in biomedical neutron activation analysis

    International Nuclear Information System (INIS)

    1984-01-01

    The summary report represents an attempt to identify some of the possible sources of error in in vitro neutron activation analysis of trace elements applied to specimens of biomedical origin and to advise on practical means to avoid them. The report is intended as guidance for all involved in analysis, including sample collection and preparation for analysis. All these recommendations constitute part of quality assurance which is here taken to encompass the two concepts - quality control and quality assessment. Quality control is the mechanism established to control errors, while quality assessment is the mechanism used to verify that the analytical procedure is operating within acceptable limits

  7. Applicability of the activation analysis with prompt neutron in medicine

    International Nuclear Information System (INIS)

    Yaghubian-Malhami, R.

    1975-04-01

    The concentrations of boron and cadmium in the human body are of great importance in medicine. The author determined their concentration by prompt neutron activation analysis in aqueous solutions and in urine. The results show that this technique may be used in medical diagnosis. The author discusses the qualities and the applicability of delayed and prompt neutron activation analysis in biology and medicine. (C.R.)

  8. Argon-ion contamination of the plasmasphere

    International Nuclear Information System (INIS)

    Chiu, Y.T.; Cornwall, J.M.; Luhmann, J.G.; Schulz, M.

    1979-01-01

    This paper applies present observational and analytic knowledge on effects of plasma beam interaction wth the magnetosphere to the plasmasphere contamination problem of the argon ion engine exhaust expected to be deposited in the magnetosphere during the construction phase of the Satellite Power System. Effects of plasmasphere, ionosphere, and radiation belt modifications are discussed

  9. Activation analysis and dendrochronology for estimating pollution histories

    International Nuclear Information System (INIS)

    Pillay, K.K.

    1976-01-01

    Neutron activation analysis of wood shavings from tree rings have shown that plant tissues grown through periods of varying environmental conditions keep permanent records of the trace elements they received though nutrients from their immediate surroundings. Detailed examination of several species of trees, along with dendrochronological data, suggest the possibilities of utilizing this technique for pollution monitoring as well as for developing valuable information for environmental modelling. The multielemental analyses of tree ring samples were done using multiple neutron irradiation and gamma-ray spectrometry using a high resolution Ge(Li) detector and a software orinted programmable multichannel analyzer. The neutron activation analysis consisted of two reactor irradiations and at least three countings at different decay periods. (T.G.)

  10. Nondestructive neutron activation analysis of volcanic samples: Hawaii

    International Nuclear Information System (INIS)

    Zoller, W.H.; Finnegan, D.L.; Crowe, B.

    1986-01-01

    Samples of volcanic emissions have been collected between and during eruptions of both Kilauea and Mauna Loa volcanoes during the last three years. Airborne particles have been collected on Teflon filters and acidic gases on base-impregnated cellulose filters. Chemically neutral gas-phase species are collected on charcoal-coated cellulose filters. The primary analytical technique used is nondestructive neutron activation analysis, which has been used to determine the quantities of up to 35 elements on the different filters. The use of neutron activation analysis makes it possible to analyze for a wide range of elements in the different matrices used for the collection and to learn about the distribution between particles and gas phases for each of the elements

  11. Elemental analysis of bottom ash from municipal incinerator by neutron activation analysis

    International Nuclear Information System (INIS)

    Kim, S. H.; Jang, S. H.; Moon, J. H.; Jung, Y. S.; Kim, Y. J.

    2003-01-01

    Elemental analysis of bottom ash generated from municipal solid waste incinerator was performed by neutron activation analysis. For this study, ash samples monthly collected from incinerator in D city were sieved with 5 mm mesh size, dried, pulverized by agate mortar and finally re-sieved with 200μ mesh size. Prepared samples were irradiated by neutrons using NAA No.1 irradiation hole in Korea Atomic Energy Research Institute. Activated samples were measured by gamma-ray spectrometer according to the relevant nuclear properties of target nuclides and the concentration of 33 elements were determined from the collected ash samples. Quality control was conducted by comparative analysis with two NIST standard reference materials simultaneously. Mean values and standard deviations of hazardous elements such as As, Cr, Cu, Fe, Mn, Sb and Zn among the determined elements were 3.8±6.9mg/kg, 620±0.12 %, 4.76±0.37 %, 0.26±0.10 %, 115±29 mg/kg and 0.71±0.19 %, respectively

  12. Determination of trace gold in rocks and minerals by neutron activation analysis

    International Nuclear Information System (INIS)

    Zhao Yunlong; Zhou Suqing; Liang Yutang

    1988-05-01

    The determination of trace gold in rocks and minerals by neutron activation analysis is described. Two methods are used for pre-separating and concentrating the trace gold in geological samples. one of the methods is that the samples are dissolved in aqua regia solution; activated carbon paper pulp filter is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the activated carbon containing gold was ashed at 650 ∼ 700 deg c. The other method is that the samples are dissolved in aqua regia solution; the polyurethane foam plastic filled with activated carbon is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the foam plastic containing gold was ashed at 650 deg c. The gold in ashes is determinated by neutron activation analysis. The detection limit is 0.004ng/g. The accuracy of the method is examined by gold in reference standard material. The results of this method are in good agreement with the recommended value. For analysis of the trace gold by the methods of instrumental neutron activation analysis and epithermal neutron activation analysis, the interference of 411.8 keV γ-ray from 153 Sm, 152 Eu and fission products of uranium and the correction methods are discussed

  13. MANAGEMENT OF THROMBOLYTIC TREATMENT IN PATIENTS WTH MASSIVE PULMONARY THROMBOEMBOLISM

    Directory of Open Access Journals (Sweden)

    Turan Aktas

    2013-09-01

    In total, whose age change between 27 and 90, who got mPTE diagnosis and received thrombolytic treatment were included in the study. Male vs. female rate was 2/3. Mortality developed in 2 patients, who were included in the study. Intracranial hemorrhage which is one of the major complications occurred in only one patient . Recurrence thromboembolism was not followed in none of the patients after the thrombolytic treatment. In mPTE, early diagnosis and rapid treatment are life saving. With the help of the diagnostic methods developing and becoming widespread lately, diagnosis of the mPTE can be made more rapidly and the treatment can be started without losing time. Moreover, it can be said that thrombolytic treatment is definitely a life saving treatment way in mPTE when it is made with close follow-up. [J Contemp Med 2013; 3(3.000: 166-172

  14. ULTRAFINE PARTICLE DEPOSITION IN HEALTHY SUBJECTS VS. PATIENTS WTH COPD

    Science.gov (United States)

    Individuals affected with chronic obstructive pulmonary disease (COPD) have increased susceptibility to adverse health effects from exposure to particulate air pollution. The dosimetry of ultrafine aerosols (diameter # 0.1 :m) is not well characterized in the healthy or diseas...

  15. Phosphorus analysis in milk samples by neutron activation analysis method

    International Nuclear Information System (INIS)

    Oliveira, R.M. de; Cunha, I.I.L.

    1991-01-01

    The determination of phosphorus in milk samples by instrumental thermal neutron activation analysis is described. The procedure involves a short irradiation in a nuclear reactor and measurement of the beta radiation emitted by phosphorus - 32 after a suitable decay period. The sources of error were studied and the established method was applied to standard reference materials of known phosphorus content. (author)

  16. Safeguards and Physics Measurements: Neutron Activation Analysis with k0-standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    2000-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation concentrates on the improvement of the standardisation method and the characterisation of the neutron field as well as on the improvement of the statistical control on neutron activation analysis. Main achievements in 2000 are reported

  17. Preliminary study of elemental analysis of hydroxyapatite used neutron activation analysis method

    International Nuclear Information System (INIS)

    Yustinus Purwamargapratala; Rina Mulyaningsih

    2010-01-01

    Preliminary study has been carried out elemental analysis of hydroxyapatite synthesized using the method of neutron activation analysis. Hydroxyapatite is the main component constituent of bones and teeth which can be synthesized from limestone and phosphoric acid. Hydroxyapatite can be used as a bone substitute material and human and animal teeth. Tests on the metal content is necessary to prevent the risk of damage to bones and teeth due to contamination. Results of analysis using neutron activation analysis method with samples irradiated at the neutron flux 10"3 n.det"-"1cm"-"2 for one minute, the impurities of Al (48.60±6.47 mg/kg), CI (38.00±7.47 mg/kg), Mn (1.05±0.19 mg/kg), and Mg (2095.30±203.66 mg/kg), were detected, whereas with irradiation time for 10 minutes and 40 minutes with a time decay of three days there were K (103.89 ± 26.82 mg/kg), Br (1617.06 ± 193.66 mg/kg), and Na (125.10±9.57 mg/kg). These results indicate that there is impurity Al, CI, Mn, Mg, Br, K and Na, although in very small amounts and do not cause damage to bones and teeth. (author)

  18. Faculty Activity Analysis in the Universidad Tecnica Del Estado Campuses.

    Science.gov (United States)

    Karadima, Oscar

    An analysis of academic activities of college faculty at the eight campuses of Chile's Universidad Tecnica del Estado was conducted. Activities were grouped into seven categories: direct teaching, indirect teaching, research, community services, faculty development, academic administration, and other activities. Following the narrative…

  19. Research activities in the fields of radiochemistry and neutron activation analysis using the LENA nuclear plant in Pavia

    International Nuclear Information System (INIS)

    Maggi, L.; Genova, N.; DiCasa, M.; Carmella-Crespi, V.

    1978-01-01

    In the past two years the activity of the Radiochemistry Laboratory and CNR Centre of Radiochemistry and Activation Analysis was mainly devoted to studies of nuclear activation analysis applied to different fields using the LENA reactor. Three NBS vegetable reference standards, Orchard Leaves, Tomato Leaves and Pine Needles, were analyzed for their halogen content. Halogen determination in foodstuff, vegetables and organic tissues gives valuable information on metabolic, nutritional, pollution and epidemiological fields. A detailed study on macro- and micro-elements content in Sardinian coal and its ashes was performed, in order to assess the possibility of using it as a fuel in electric power generating plants. Instrumental neutron activation analysis was used for the determination of Al, Si, Mn, Mg, Na, V, CI, Ce, Yb, Th, Cr, Hf, Cs, Se, Rb, Fe, Co, Ta, Eu, K, La and Sb. A multielement trace analysis of rock samples was developed in cooperation with scientists from other Universities; the determination of R.E., U, Th, Zr, Cs, Ba, Ni, Sc, Ta, Hf, Sr, and Cr by instrumental neutron activation analysis was carried out in connection with orogenetic studies of African Rocks. In the archaeological field ancient artefacts recently discovered during a digging campaign at Monza's Cathedral (Italy) were analyzed with the aim to trace their origin and compare their composition with similar samples whose dating is certain. As a contribute to the international program of certifying NBS reference standard materials, chromium in the Brewer's Yeast, recently proposed as a new SRM, was determined by both instrumental and destructive neutron activation analysis. In the study of the role and behaviour of trace elements in human physiology, vanadium was investigated in human blood, as a trace element of increasing interest in connection with its origin from pollutants. Nuclear activation analysis was also applied to marine organism samples under a contract for oceanographic research

  20. Applications of neutron activation analysis in chemistry and pollution fields

    International Nuclear Information System (INIS)

    May, S.

    1978-01-01

    Some examples of applications of activation analysis are given such as: chemical analysis of precious metals, nuclear graphite and hydrocarbons; control of pollution of water and seawater, analysis of food and seafood, atmospheric, dust and hair for determination of impurities [fr

  1. Characterization of ashes from a 100 kWth pilot-scale circulating fluidized bed with oxy-fuel combustion

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Y.H.; Wang, C.B.; Tan, Y.W.; Jia, L.F.; Anthony, E.J. [Natural Resources Canada, Ottawa, ON (Canada)

    2011-09-15

    Oxy-fuel combustion experiments have been carried out on an oxygen-fired 100 kW(th) mini-circulating fluidized bed combustion (CFBC) facility. Coal and petroleum coke were used as fuel together with different limestones (and fixed Ca:S molar ratios) premixed with the fuel, for in situ SO{sub 2} capture. The bed ash (BA) and fly ash (FA) samples produced from this unit were collected and characterized to obtain physical and chemical properties of the ash samples. The characterization methods used included X-ray fluorescence (XRF), X-ray diffraction (XRD), char carbon and free lime analysis, thermogravimetric analysis (TGA), and surface analysis. The main purpose of this work is to characterize the CFBC ashes from oxy-fuel firing to obtain a better understanding of the combustion process, and to identify any significant differences from the ash generated by a conventional air-fired CFBC. The primary difference in the sulfur capture mechanism between atmospheric air-fired and oxy-fuel FBC, at typical FBC temperatures (similar to 850{sup o}C), is that, in the air-fired case the limestone sorbents calcine, whereas the partial pressure of CO{sub 2} in oxy-fuel FBC is high enough to prevent calcination, and hence the sulfation process should mimic that seen in pressurized FBC (PFBC). Here, the char carbon content in the fly ash was much higher than that in the bed ash, and was also high by comparison with ash obtained from conventional commercial air-firing CFBC units. In addition, measurements of the free lime content in the bed and fly ash showed that the unreacted Ca sorbent was present primarily as CaCO{sub 3}, indicating that sulfur capture in the oxy-fuel combustor occurred via direct sulfation.

  2. Development of HANARO Activation Analysis System and Utilization Technology

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Cho, H. J. (and others)

    2007-06-15

    1. Establishment of evaluation system using a data for a neutron activation analysis : Improvement of NAA measurement system and its identification, Development of combined data evaluation code of NAA/PGAA, International technical cooperation project 2. Development of technique for a industrial application of high precision gamma nuclide spectroscopic analysis : Analytical quality control, Development of industrial application techniques and its identification 3. Industrial application research for a prompt gamma-ray activation analysis : Improvement of Compton suppression counting system (PGAA), Development of applied technology using a PGAA system 4. Establishment of NAA user supporting system and KOLAS management : Development and validation of KOLAS/ISO accreditation testing and identification method, Cooperation researches for a industrial application, Establishment of integrated user analytical supporting system, Accomplishment of sample irradiation facility.

  3. Development of HANARO Activation Analysis System and Utilization Technology

    International Nuclear Information System (INIS)

    Chung, Y. S.; Moon, J. H.; Cho, H. J.

    2007-06-01

    1. Establishment of evaluation system using a data for a neutron activation analysis : Improvement of NAA measurement system and its identification, Development of combined data evaluation code of NAA/PGAA, International technical cooperation project 2. Development of technique for a industrial application of high precision gamma nuclide spectroscopic analysis : Analytical quality control, Development of industrial application techniques and its identification 3. Industrial application research for a prompt gamma-ray activation analysis : Improvement of Compton suppression counting system (PGAA), Development of applied technology using a PGAA system 4. Establishment of NAA user supporting system and KOLAS management : Development and validation of KOLAS/ISO accreditation testing and identification method, Cooperation researches for a industrial application, Establishment of integrated user analytical supporting system, Accomplishment of sample irradiation facility

  4. 14 MeV proton activation analysis

    International Nuclear Information System (INIS)

    Constantinescu, B.; Ivanov, E.; Plostinaru, D.; Popa-Nemoiu, A.; Pascovichi, G.

    1985-01-01

    A fast nuclear nondestructive method for protein analysis using the 14 MeV proton activation has been developed. The total nitrogen content was measured through the reaction: 14 N (p,n) 14 O, (Tsub(1/2)=71 s). The 14 O activity was detected by means of its characteristic 2.312 MeV gamma-ray line with a NaI(Tl) detector. For a fast determination of a large number of samples a mechanized sistem reacting a rate of one sample per minute has been developed. The laboratory electronics comprises a multichannel analyser, a PDP computer and an electronic module comtroller. Comparison of the results obtained by the method described and the classical Kjeldal technique for samples of various cereal grains (soya bean seads, wheat, barley and corn) showed good correlation. A problem of the analysis of the whole protein region on corn and soya-bean seads, where this region is thicker (0,2 - 2 mm), is mentioned. In this case flour was proposed to be used to obtain a protein homogeneous sample and the irradiaton dose for a sample was about 33,000 Gy, mainly (99%) from protons (27 s x 100 nA x 14 MeV)

  5. Content Analysis in Systems Engineering Acquisition Activities

    Science.gov (United States)

    2016-04-30

    Acquisition Activities Karen Holness, Assistant Professor, NPS Update on the Department of the Navy Systems Engineering Career Competency Model Clifford...systems engineering toolkit . Having a common analysis tool that is easy to use would support the feedback of observed system performance trends from the

  6. Neutron activation analysis for noble metals in matte leach residues

    International Nuclear Information System (INIS)

    Hart, R.J.

    1978-01-01

    The development of the neutron activation analysis technique as a method for rapid and precise determinations of platinum group metals in matte leach residues depends on obtaining a method for effecting complete and homogeneous sample dilution. A simple method for solid dilution of metal samples is outlined in this study, which provided a basis for the accurate determination of all the noble metals by the Neutron Activation Analysis technique

  7. Non-traditional neutron activation analysis by use of a nuclear reactor

    International Nuclear Information System (INIS)

    Mukhammedov, S.

    2003-01-01

    Full text: Traditional reactor neutron activation analysis (NAA) based on (n, γ) - thermal neutron capture nuclear reaction has been developed into a reliable and powerful analytical method, for trace element analysis, allowing the determination of over 60 chemical elements, with good accuracy and low detection limits. Considering all possibilities of activation and a radiochemical separation of the indicator radionuclide, the majority of the elements of this group can be determined at the ppm concentration level and below. However, for solving a number of analytical problems NAA technique is not well suited or it cannot be used at all. An important limitation is that all light elements, some medium and heavy elements cannot be determined even at ppm concentration level by this method, for example, H, Be, Li, B, C, N, O, Ti, Nb, Pb, etc. Accurate determination of lithium, oxygen and other light elements in sub-microgram level is of importance in geochemical and material studies. Such examples are great many. On such instances, several non-traditional reactor activation analysis can be used which have increasingly been developed and applied to several fields of semiconductor industry, biology, geology in recent years. The purpose of this presentation is to review the modern status of non-traditional nuclear reactor activation analysis based on use of nuclear reactions excited by the flow of secondary charged particles which are produced by two methods. In first method the triton flow is produced by thermal neutrons flux which excites the nuclear reaction 6 Li(n, α)T on lithium. The neutron activation analysis associated with two consecutive reactions 6 Li(n, α)T + 16 O(T, n) 18 F is established to determine trace amounts either of lithium or of oxygen in different geological, ecological and technological samples. Besides, the triton flow can be used for the determination of other light elements, for instance, B, N, S, Mg. This nuclear reactor triton activation

  8. Precision of neutron activation analysis for environmental biological materials

    International Nuclear Information System (INIS)

    Hamaguchi, Hiroshi; Iwata, Shiro; Koyama, Mutsuo; Sasajima, Kazuhisa; Numata, Yuichi.

    1977-01-01

    Between 1973 and 1974 a special committee ''Research on the application of neutron activation analysis to the environmental samples'' had been organized at the Research Reactor Institute, Kyoto University. Eleven research groups composed mainly of the committee members cooperated in the intercomparison programme of the reactor neutron activation analysis of NBS standard reference material, 1571 Orchard Leaves and 1577 Bovine Liver. Five different type of reactors were used for the neutron irradiation; i.e. KUR reactor of the Research Reactor Institute, Kyoto University, TRIGA MARK II reactor of the Institute for Atomic Energy, Rikkyo University, and JRR-2, JRR-3, JRR-4 reactor of Japan Atomic Energy Research Institute. Analyses were performed mainly by instrumental method. Precision of the analysis of 23 elements in Orchard Leaves and 13 elements in Bovine Liver presented by the different research groups was shown in table 4 and 5, respectively. The coefficient of variation for these elements was from several to -- 30 percent. Averages given to these elements agreed well with the NBS certified or reference values. Thus, from the practical point of view for the routine multielement analysis of environmental samples, the validity of the instrumental neutron activation technique for this purpose has been proved. (auth.)

  9. Spatial heterogeneity analysis of brain activation in fMRI

    Directory of Open Access Journals (Sweden)

    Lalit Gupta

    2014-01-01

    Full Text Available In many brain diseases it can be qualitatively observed that spatial patterns in blood oxygenation level dependent (BOLD activation maps appear more (diffusively distributed than in healthy controls. However, measures that can quantitatively characterize this spatial distributiveness in individual subjects are lacking. In this study, we propose a number of spatial heterogeneity measures to characterize brain activation maps. The proposed methods focus on different aspects of heterogeneity, including the shape (compactness, complexity in the distribution of activated regions (fractal dimension and co-occurrence matrix, and gappiness between activated regions (lacunarity. To this end, functional MRI derived activation maps of a language and a motor task were obtained in language impaired children with (Rolandic epilepsy and compared to age-matched healthy controls. Group analysis of the activation maps revealed no significant differences between patients and controls for both tasks. However, for the language task the activation maps in patients appeared more heterogeneous than in controls. Lacunarity was the best measure to discriminate activation patterns of patients from controls (sensitivity 74%, specificity 70% and illustrates the increased irregularity of gaps between activated regions in patients. The combination of heterogeneity measures and a support vector machine approach yielded further increase in sensitivity and specificity to 78% and 80%, respectively. This illustrates that activation distributions in impaired brains can be complex and more heterogeneous than in normal brains and cannot be captured fully by a single quantity. In conclusion, heterogeneity analysis has potential to robustly characterize the increased distributiveness of brain activation in individual patients.

  10. Active Desiccant-Based Preconditioning Market Analysis and Product Development

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, J.

    2001-01-11

    The Phase 1 report (ORNL/Sub/94-SVO44/1), completed earlier in this program, involved a comprehensive field survey and market analysis comparing various specialized outdoor air handling units. This initial investigation included conventional cooling and reheat, conventional cooling with sensible recovery, total energy recovery systems (passive desiccant technology) and various active desiccant systems. The report concluded that several markets do promise a significant sales opportunity for a Climate Changer-based active desiccant system offering. (Climate Changer is a registered trademark of Trane Company.) This initial market analysis defined the wants and needs of the end customers (design engineers and building owners), which, along with subsequent information included in this report, have been used to guide the determination of the most promising active desiccant system configurations. This Phase 2 report begins with a summary of a more thorough investigation of those specific markets identified as most promising for active desiccant systems. Table 1 estimates the annual sales potential for a cost-effective product line of active desiccant systems, such as that built from Climate Changer modules. The Product Development Strategy section describes the active desiccant system configurations chosen to best fit the needs of the marketplace while minimizing system options. Key design objectives based on market research are listed in this report for these active desiccant systems. Corresponding performance goals for the dehumidification wheel required to meet the overall system design objectives are also defined. The Performance Modeling section describes the strategy used by SEMCO to design the dehumidification wheels integrated into the prototype systems currently being tested as part of the U.S. Department of Energy's Advanced Desiccant Technology Program. Actual performance data from wheel testing was used to revise the system performance and energy analysis

  11. Neutron activation analysis of atmospheric aerosols

    International Nuclear Information System (INIS)

    Riekstinya, D.V.; Mednis, I.V.; Veveris, O.Eh.

    1987-01-01

    A review of studies by Soviet and foreign authors on radioactivation analysis is presented. Instrumental neutron activation analysis (INAA) techniques have been developed providing the possibility to determine a number of elements in very small portions of aerosols for pollutanless areas of the Earth. Two ways of INAA are presented: with long- and short-living radionuclides. The Antarctic and the Indian Ocean aerosol samples have been analysed for 26 microelements. It has been stated that restrictions of the detection limits attained relate to high proportions of certain elements and their nonhomogeneous distribution in filters. The detection limits can be lowered by the filtered air volume growth per unit of the filter area

  12. Aspects of precision and accuracy in neutron activation analysis

    International Nuclear Information System (INIS)

    Heydorn, K.

    1980-03-01

    Analytical results without systematic errors and with accurately known random errors are normally distributed around their true values. Such results may be produced by means of neutron activation analysis both with and without radiochemical separation. When all sources of random variation are known a priori, their effect may be combined with the Poisson statistics characteristic of the counting process, and the standard deviation of a single analytical result may be estimated. The various steps of a complete neutron activation analytical procedure are therefore studied in detail with respect to determining their contribution to the overall variability of the final result. Verification of the estimated standard deviation is carried out by demonstrating the absence of significant unknown random errors through analysing, in replicate, samples covering the range of concentrations and matrices anticipated in actual use. Agreement between the estimated and the observed variability of replicate results is then tested by a simple statistic T based on the chi-square distribution. It is found that results from neutron activation analysis on biological samples can be brought into statistical control. In routine application of methods in statistical control the same statistical test may be used for quality control when some of the actual samples are analysed in duplicate. This analysis of precision serves to detect unknown or unexpected sources of variation of the analytical results, and both random and systematic errors have been discovered in practical trace element investigations in different areas of research. Particularly, at the ultratrace level of concentration where there are few or no standard reference materials for ascertaining the accuracy of results, the proposed quality control based on the analysis of precision combined with neutron activation analysis with radiochemical separation, with an a priori precision independent of the level of concentration, becomes a

  13. Applied research and development of neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Ryel; Kim, Young Gi; Jung, Hwan Sung; Park, Kwang Won; Kang, Sang Hun; Lim, Jong Myoung

    2003-05-01

    The aims of this project are to establish the quality control system of Neutron Activation Analysis(NAA) due to increase of industrial needs for standard analytical method and to prepare and identify the standard operation procedure of NAA through practical testing for different analytical items. R and D implementations of analytical quality system using neutron irradiation facility and gamma-ray measurement system and automation of NAA facility in HANARO research reactor are as following ; 1) Establishment of NAA quality control system for the maintenance of best measurement capability and the promotion of utilization of HANARO research reactor 2) Improvement of analytical sensitivity for industrial applied technologies and establishment of certified standard procedures 3) Standardization and development of Prompt Gamma-ray Activation Analysis (PGAA) technology

  14. On-stream analysis of coal by prompt neutron activation analysis

    International Nuclear Information System (INIS)

    Barker, D.

    1981-01-01

    The need for rapid continuous on-stream analysis of coal was recognised in 1975. Analytical systems capable of determining some of the most important compositional properties of coal have been developed. The research programme has produced a series of analysers suitable for on-stream, batch, slurry and laboratory analytical determination of coal. This series of analysers is marketed under the name of 'Nucoalyzer'. The Nucoalyzer - CONAC (Continuous On-line Nuclear Analyzer for Coal) offers real-time, continuous determination of calorific value, percentage ash, percentage moisture, percentage sulphur, boiler fouling and slagging indices. The CONAC model is described in this article. The analytical principle employed in the various Nucoalyzer systems is based on prompt neutron activation analysis

  15. Activation analysis of deposited dust brought to Israel by dust storms

    International Nuclear Information System (INIS)

    Ganor, E.; Tal, A.; Donagi, A.

    1975-01-01

    The determination of dust particles deposited in Jerusalem during regional dust storms was carried out by polarized microscopy, X-ray analysis and atomic absorption measurements. These analyses showed the presence of particles of quartz, calcite, dolomite, feldspar, halite, kaolinite, montmorillonite, epidote, tourmaline, glauconite, illite and other heavy minerals. The aims of the present study were to apply activation analysis for the determination of element composition in dust samples; to compare the results obtained by activation analysis with those obtained by other methods, i.e. chemical analysis, polarized microscopy and X-ray analysis. The results obtained by the various methods were in good agreement. (B.G.)

  16. Feed intake and nutrient digestibility of West African Dwarf (WAD ...

    African Journals Online (AJOL)

    Nine (9) West African dwarf goats (8 weeks of age,averaging 6.3 + 1.3 kg body weight) were used in a 42 day feeding trial to determine the effec of feeding Pennisetum purpureum supplemented with Gmelina arborea on diet intake and nutrient digesibility of goats. The experimental diets were diets 1 2 and 3 wth 0%, 25%, ...

  17. retrograde pyelography and ureteric catheterization

    African Journals Online (AJOL)

    phase, this being compatible w:th obstruction (Fig. 2). After 24 hours of anuria, the patient proceeded to pass blood-stained urine, having received intravenous fluids, mannitol and furosemide. Her blood urea rose from the pre-operative figure of 47 mg/lOO ml to 144 mg/lOO ml on the fourth postoperative day; subsequ::ntIy, ...

  18. Application of X-ray spectroscopy in nondestructive photon activation analysis

    International Nuclear Information System (INIS)

    Weise, H.-P.; Segebade, Chr.

    1977-01-01

    The use of X-ray spectroscopy for the qualitative and quantitative analysis of samples activated by 30 MeV bremsstrahlung from an electron linear accelerator. Detection limits are calculated from the measured X-ray spectra and compared with those for γ-ray spectroscopy. In general, the detection limits for γ-ray and X-ray spectroscopy are comparable. Higher sensitivities for X-ray spectroscopy are observed when only low intensity γ-rays are emitted by the activation products. X-ray spectroscopy should be applied in three cases: (a) low γ-ray emission probability, (b) extremely complicated γ-ray spectrum, (c) overlapping of γ-ray lines from different elements. γ-ray spectroscopy should be preferred for the analysis of light elements for two reasons: very strong absorption of low energy X-rays (low Z) within the sample, low X-ray emission probability for the activation products of light elements. Therefore no attempt was made to use X-ray spectroscopy for the analysis of elements below Ti. Some practical applications of X-ray spectroscopy in nondestructive multielement analysis are quoted. (T.G.)

  19. Compositional Analysis and Antioxidant Activity of Volatile ...

    African Journals Online (AJOL)

    Compositional Analysis and Antioxidant Activity of Volatile. Components of Two Salvia spp. F Forouzin*, R Jamei and R Heidari. Department of Biology, Faculty of Science, Urmia University, West Azerbaijan, Iran. *For correspondence: Email: f_forouzin@yahoo.com, rjamei274@gmail.com, r.heidari@mail.urmia.ac.ir; Tel: ...

  20. Prehistory analysis using photon activation analysis

    International Nuclear Information System (INIS)

    Krausova, I.; Chvatil, D.; Tajer, J.

    2017-01-01

    Instrumental photon activation analysis (IPAA) is a suitable radio-analytical method for non-destructive determination of total nitrogen in various matrices. IPAA determination of nitrogen is based on 14 N (γ, n) 13 N nuclear reaction after high-energy photon irradiation. The analytically usable product of this photo-nuclear reaction is a positron emitter emitting only non-specific annihilation of 511 keV, which can be emitted by other radionuclides present in the sample. Some of them, besides the non-specific 511 keV line, also emit specific lines that allow their contribution to analytical radionuclide 13 N to be subtracted. An efficient source of high-energy photon radiation is the secondary bremsstrahlung generated by the conversion of the electron beam accelerated by a high-frequency circular accelerator - a microtron. The non-destructive IPAA contributed to the clarification of the origins of a precious bracelet originating from a fortified settlement in the area of Karlovy Vary - Drahovice from the late Bronze Age. (authors)

  1. Effect of activation cross section uncertainties in transmutation analysis of realistic low-activation steels for IFMIF

    Energy Technology Data Exchange (ETDEWEB)

    Cabellos, O.; Garcya-Herranz, N.; Sanz, J. [Institute of Nuclear Fusion, UPM, Madrid (Spain); Cabellos, O.; Garcya-Herranz, N.; Fernandez, P.; Fernandez, B. [Dept. of Nuclear Engineering, UPM, Madrid (Spain); Sanz, J. [Dept. of Power Engineering, UNED, Madrid (Spain); Reyes, S. [Safety, Environment and Health Group, ITER Joint Work Site, Cadarache Center (France)

    2008-07-01

    We address uncertainty analysis to draw conclusions on the reliability of the activation calculation in the International Fusion Materials Irradiation Facility (IFMIF) under the potential impact of activation cross section uncertainties. The Monte Carlo methodology implemented in ACAB code gives the uncertainty estimates due to the synergetic/global effect of the complete set of cross section uncertainties. An element-by-element analysis has been demonstrated as a helpful tool to easily analyse the transmutation performance of irradiated materials.The uncertainty analysis results showed that for times over about 24 h the relative error in the contact dose rate can be as large as 23 per cent. We have calculated the effect of cross section uncertainties in the IFMIF activation of all different elements. For EUROFER, uncertainties in H and He elements are 7.3% and 5.6%, respectively. We have found significant uncertainties in the transmutation response for C, P and Nb.

  2. Optimization of instrumental activation analysis conditions

    International Nuclear Information System (INIS)

    Guinn, V.; Gavrilas-Guinn, M.

    1993-01-01

    In instrumental neutron activation analysis (INAA) work, a good commonsense rule of thumb is that the opium conditions for the measurement of any induced activity, in a multi-element sample matrix, are an irradiation time, a decay time, and a counting time each approximately equal to the half-life of the radionuclide (if feasible). The INAA Advance Computer Program (APCP) was used to test this rule on ten reference materials. For the 280 radionuclide/material combinations traced through all 14 APCP condition sets, the rule predicted the best set for 67% of them, was off by one set for 31% of them, and was only off by two sets of 2% of them. (author) 6 refs.; 1 fig.; 3 tabs

  3. Development of prompt gamma activation analysis

    International Nuclear Information System (INIS)

    Olmez, I.

    1982-01-01

    Application of prompt gamma-activation analysis to some environmental samples and NBS's standard reference materials were examined, using NBS reactor and the technique developed by the nuclear chemistry group of the University of Maryland. Concentration of several elements, Cd, B, S, Se, Sb, Zn, Ba, Cr, Cs, Co, Si, Hf, Ce, Yb, Lu, Th, Sc, Eu, Fe, Ta and Rb, were determined by both PGAA and INAA. (author)

  4. Increasing physical activity with mobile devices: a meta-analysis.

    Science.gov (United States)

    Fanning, Jason; Mullen, Sean P; McAuley, Edward

    2012-11-21

    Regular physical activity has established physical and mental health benefits; however, merely one quarter of the U.S. adult population meets national physical activity recommendations. In an effort to engage individuals who do not meet these guidelines, researchers have utilized popular emerging technologies, including mobile devices (ie, personal digital assistants [PDAs], mobile phones). This study is the first to synthesize current research focused on the use of mobile devices for increasing physical activity. To conduct a meta-analysis of research utilizing mobile devices to influence physical activity behavior. The aims of this review were to: (1) examine the efficacy of mobile devices in the physical activity setting, (2) explore and discuss implementation of device features across studies, and (3) make recommendations for future intervention development. We searched electronic databases (PubMed, PsychINFO, SCOPUS) and identified publications through reference lists and requests to experts in the field of mobile health. Studies were included that provided original data and aimed to influence physical activity through dissemination or collection of intervention materials with a mobile device. Data were extracted to calculate effect sizes for individual studies, as were study descriptives. A random effects meta-analysis was conducted using the Comprehensive Meta-Analysis software suite. Study quality was assessed using the quality of execution portion of the Guide to Community Preventative Services data extraction form. Four studies were of "good" quality and seven of "fair" quality. In total, 1351 individuals participated in 11 unique studies from which 18 effects were extracted and synthesized, yielding an overall weight mean effect size of g = 0.54 (95% CI = 0.17 to 0.91, P = .01). Research utilizing mobile devices is gaining in popularity, and this study suggests that this platform is an effective means for influencing physical activity behavior. Our focus

  5. Trace analysis measurements in high-purity aluminium by means of radiochemical neutron and proton activation analysis

    International Nuclear Information System (INIS)

    Egger, K.P.

    1987-01-01

    The aim of the study consisted in the development of efficient radiochemical composite processes and activation methods for the multi-element determination of traces within the lower ng range in high-purity aluminium. More than 50 elements were determined with the help of activation with reactor neutrons; the selective separation of matrix activity (adsorption with hydrated antimony pentoxide) led to a noticeable improvement of detectability, as compared with instrumental neutron activation analysis. Further improvements were achieved with the help of radiochemical group separations in ion exchangers or with the help of the selective separation of the pure beta-emitting elements. Over 20 elements up to high atomic numbers were determined by means of activating 13 MeV protons and 23 Me protons. In this connection, improvements of the detection limit by as a factor of 10 were achieved with radiochemical separation techniques, as compared with pure instrumental proton activation analysis. (RB) [de

  6. Elemental Study in Soybean and Products by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Vorapot, Permnamtip; Arporn Busamongkol; Sirinart, Laoharojanaphand

    2009-07-01

    Full text: Elements were analyzed in soybean and products by Instrumental Neutron Activation Analysis (INAA), Pseudo-Cyclic Instrumental Neutron Activation Analysis (PCINAA) and Epithermal Instrumental Neutron Activation Analysis (EINAA). Elements detected in sample were include Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn. The result showed that the nutritional contents changed after food processing. From experiments (n = 2), it was found that after food processing, the concentration of Cl and Na in soy bean curd increased from 0.0045 and 0.0011% to found 0.91 and 0.39 %, respectively. Other elements did not differ from soybean. Limits of detection for Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn were 0.05, 0.2, 50, 6, 10, 15, 0.05, 30, 40, 5, 5, 0.05 and 1 mg.kg - 1, respectively

  7. Major indicators of analysis of insurers’ investment activity

    Directory of Open Access Journals (Sweden)

    O.O. Poplavskyi

    2016-12-01

    Full Text Available The article is devoted to topical issues of economic nature, selection and use of economic indicators in analysis of insurers’ investment activity. The author determines the main criteria of permissible investment activity, such as different assets covering the insurance reserves and share of various types of investments in assets and capital on the base of the results of summarizing recent public requirements of key banks to insurance companies in Ukraine. The recommendations of the insurers’ analysis approved by the regulatory bodies in Ukraine (the State Commission for Regulation of Financial Services Markets, Belarus (the Ministry of Finance and Poland (the Financial Supervision Authority are not left without author’s attention. According to the results of comparing using of different indicators, like the return on equity and investment, their strength and weaknesses are identified and the improving the scales of their assessment are proposed. The article singles out the main indicators which can be adapted to national features+ and used for management decisions and regulation of investment activities of insurers.

  8. Content Analysis of a Computer-Based Faculty Activity Repository

    Science.gov (United States)

    Baker-Eveleth, Lori; Stone, Robert W.

    2013-01-01

    The research presents an analysis of faculty opinions regarding the introduction of a new computer-based faculty activity repository (FAR) in a university setting. The qualitative study employs content analysis to better understand the phenomenon underlying these faculty opinions and to augment the findings from a quantitative study. A web-based…

  9. Thermal analysis of physical and chemical changes occuring during regeneration of activated carbon

    Directory of Open Access Journals (Sweden)

    Radić Dejan B.

    2017-01-01

    Full Text Available High-temperature thermal process is a commercial way of regeneration of spent granular activated carbon. The paper presents results of thermal analysis conducted in order to examine high-temperature regeneration of spent activated carbon, produced from coconut shells, previously used in drinking water treatment. Results of performed thermogravimetric analysis, derivative thermogravimetric analysis, and differential thermal analysis, enabled a number of hypotheses to be made about different phases of activated carbon regeneration, values of characteristic parameters during particular process phases, as well as catalytic impact of inorganic materials on development of regeneration process. Samples of activated carbon were heated up to 1000°C in thermogravimetric analyser while maintaining adequate oxidizing or reducing conditions. Based on diagrams of thermal analysis for samples of spent activated carbon, temperature intervals of the first intense mass change phase (180-215°C, maximum of exothermic processes (400-450°C, beginning of the second intense mass change phase (635-700°C, and maximum endothermic processes (800-815°C were deter-mined. Analysing and comparing the diagrams of thermal analysis for new, previously regenerated and spent activated carbon, hypothesis about physical and chemical transformations of organic and inorganic adsorbate in spent activated carbon are given. Transformation of an organic adsorbate in the pores of activated carbon, results in loss of mass and an exothermic reaction with oxygen in the vapour phase. The reactions of inorganic adsorbate also result the loss of mass of activated carbon during its heating and endothermic reactions of their degradation at high temperatures.

  10. Neutron activation analysis of absolutely-dated tree rings

    International Nuclear Information System (INIS)

    Uenlue, K.; Hauck, D.K.; Kuniholm, P.I.; Chiment, J.J.

    2005-01-01

    Gold concentration was determined for dendrochronologically-dated wood samples using neutron activation analysis (NAA) and correlation sought with known environmental changes, e.g., volcanic activities, during historic periods. Uptake of gold is sensitive to soil pH for many plants. Data presented are from a single, cross-dated tree that grew in Greece. Using NAA, gold was measured with parts-per-billion sensitivity in individual tree rings from 1411 to 1988 AD. (author)

  11. Comparison of 3D quantitative structure-activity relationship methods: Analysis of the in vitro antimalarial activity of 154 artemisinin analogues by hypothetical active-site lattice and comparative molecular field analysis

    Science.gov (United States)

    Woolfrey, John R.; Avery, Mitchell A.; Doweyko, Arthur M.

    1998-03-01

    Two three-dimensional quantitative structure-activity relationship (3D-QSAR) methods, comparative molecular field analysis (CoMFA) and hypothetical active site lattice (HASL), were compared with respect to the analysis of a training set of 154 artemisinin analogues. Five models were created, including a complete HASL and two trimmed versions, as well as two CoMFA models (leave-one-out standard CoMFA and the guided-region selection protocol). Similar r2 and q2 values were obtained by each method, although some striking differences existed between CoMFA contour maps and the HASL output. Each of the four predictive models exhibited a similar ability to predict the activity of a test set of 23 artemisinin analogues, although some differences were noted as to which compounds were described well by either model.

  12. Utilization and facility of neutron activation analysis in HANARO research reactor

    International Nuclear Information System (INIS)

    Chung, Y.S.; Chung, Y.J.; Moon, J.H.

    1998-01-01

    The facilities of neutron activation analysis within a multi-purpose research reactor (HANARO) are described and the main applications of Neutron activation analysis (NAA) in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, are installed at three irradiation holes. One irradiation hole is lined with a cadmium tube for epithermal-nal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and polyethylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3.9x10 13 -1.6x10 14 n/cm 2 ·s and cadmium ratios are 15-250. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Analytical services and the latest analytical results are summarized. (author)

  13. Multielement analysis of archaic Chinese bronze and antique coins by fast neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Y.H. (Academia Sinica, Lanzhou, Gansu (China). Inst. of Modern Physics); Pepelnik, R.; Fanger, H.U. (GKSS-Forschungszentrum Geesthacht GmbH, Geesthacht-Tesperhude (Germany, F.R.). Inst. fuer Physik)

    1990-01-01

    Samples of archaic bronze have been investigated by fast neutron activation analysis using both the absolute and relative method. The components Cu, Zn, Sn and Pb have been determined quantitatively. For the detection of lead via the short-lived isomeric state {sup 207m}Pb, cyclic activation and measurement technique was used with pneumatic sample transfer between detector and central irradiation position of the neutron tube. For non-destructive analysis of antique Chinese coins the samples had to be irradiated outside the neutron generator KORONA. The activation reactions, the evaluation of the elemental concentrations and the accuracy of the results are discussed. The data were corrected for {gamma}-ray self-absorption in the samples and summing of coincident {gamma}-rays in the detector. According to reported typical compositions of Chinese bronze from different dynasties, the age of the samples has been derived from the results obtained. (orig.).

  14. Application of prompt gamma-ray activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Park, Kwang Won; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Ryel [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-03-01

    This technical report is written for the promotion to utilization of prompt gamma-ray activation analysis facility to be installed in HANARO reactor. It is described for a practical aspects including experiment and equipments, methodology, current status of the research and development and its applications. 102 refs., 32 figs., 25 tabs. (Author)

  15. Isotopic neutron sources for neutron activation analysis

    International Nuclear Information System (INIS)

    Hoste, J.

    1988-06-01

    This User's Manual is an attempt to provide for teaching and training purposes, a series of well thought out demonstrative experiments in neutron activation analysis based on the utilization of an isotopic neutron source. In some cases, these ideas can be applied to solve practical analytical problems. 19 refs, figs and tabs

  16. Elemental analysis of combustion products by neutron activation

    International Nuclear Information System (INIS)

    Heft, R.E.; Koszykowski, R.F.

    1980-01-01

    This paper gives a brief description of the neutron activation analysis method, which is being used to determine the elemental profile of combustion products from coal-fired power plants, oil shale retorting, and underground coal gasification

  17. Neutron activation analysis for certification of standard reference materials

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Hernandez Rivero, A.; Ribeiro Guevara, S.

    1996-01-01

    Neutron activation analysis is used extensively as one of the analytical techniques in the certification of standard reference materials. Characteristics of neutron activation analysis which make it valuable in this role are: accuracy multielemental capability to asses homogeneity, high sensitivity for many elements, and essentially non-destructive method. This paper report the concentrations of 30 elements (major, minor and trace elements) in four Cuban samples. The samples were irradiated in a thermal neutron flux of 10 12- 10 13 n.cm 2. s -1. The gamma ray spectra were measured by HPGe detectors and were analyzed using ACTAN program development in Center of Applied Studies for Nuclear Development

  18. On neutron activation analysis with γγ coincidence spectrometry

    International Nuclear Information System (INIS)

    Zeisler, Rolf; Danyal Turkoglu; Ibere Souza Ribeiro Junior; Shetty, M.G.

    2017-01-01

    A new γγ coincidence system has been set up at NIST. It is operated with a digital data finder supported by new software developed at NIST. The system is used to explore possible enhancements in instrumental neutron activation analysis (INAA) and study applicability to neutron capture prompt gamma activation analysis (PGAA). The performance of the system is tested with certified reference materials for efficiency calibration and quantitative performance. Comparisons of INAA results based on conventional gamma-ray spectrometry data with INAA results based on coincidence data obtained from the same samples show improvements in the counting uncertainties and demonstrates the quantitative accuracy of the new system. (author)

  19. Determination of silver using cyclic epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Pun, T.H.; Landsberger, S.

    2012-01-01

    A fast pneumatic transfer facility was installed in Nuclear Engineering Teaching Laboratory (NETL) of the University of Texas at Austin for the purpose of cyclic thermal and epithermal neutron activation analysis. In this study efforts were focused on the evaluation of cyclic epithermal neutron activation analysis (CENAA). Various NIST and CANMET certified materials were analyzed by the system. Experiment results showed 110 Ag with its 25 s half-life as one of the isotopes favored by the system. Thus, the system was put into practical application in identifying silver in metallic ores. Comparison of sliver concentrations as determined by CENAA in CANMET certified reference materials gave very good results. (author)

  20. Modern trends in activation analysis. Vols. 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Henkelmann, R; Kim, J I; Lux, F; Staerk, H; Zeisler, R [eds.

    1976-01-01

    Two volumes contain 164 special papers presented at the international conference on activation analysis, including five plenary lectures which give a general survey of modern trends and possibilities of applications in fields where activation analysis is capable of solving problems which are hitherto unsolved. The emphasis during this meeting is put on applications, though other subjects (e.g. sampling, homogeneity of samples, instrumental development, computer evaluation of gamma spectra, comparisons with other analytical methods) are also dealt with. The proceedings contain lectures on applications in the fields of biology, biomedicine, archaeology, the arts, forensic sciences, environmental research, ecology, materials research, geo- and cosmo-sciences, and other individual applications.

  1. Affective mapping: An activation likelihood estimation (ALE) meta-analysis.

    Science.gov (United States)

    Kirby, Lauren A J; Robinson, Jennifer L

    2017-11-01

    Functional neuroimaging has the spatial resolution to explain the neural basis of emotions. Activation likelihood estimation (ALE), as opposed to traditional qualitative meta-analysis, quantifies convergence of activation across studies within affective categories. Others have used ALE to investigate a broad range of emotions, but without the convenience of the BrainMap database. We used the BrainMap database and analysis resources to run separate meta-analyses on coordinates reported for anger, anxiety, disgust, fear, happiness, humor, and sadness. Resultant ALE maps were compared to determine areas of convergence between emotions, as well as to identify affect-specific networks. Five out of the seven emotions demonstrated consistent activation within the amygdala, whereas all emotions consistently activated the right inferior frontal gyrus, which has been implicated as an integration hub for affective and cognitive processes. These data provide the framework for models of affect-specific networks, as well as emotional processing hubs, which can be used for future studies of functional or effective connectivity. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Instrumental Neutron Activation Analysis for Human Hair

    International Nuclear Information System (INIS)

    Ratanatongchai, W.; Dharmvanij, W; Chongkum, S.

    1998-01-01

    Hair samples from students aged between 7 to 22 years old were analysed by neutron activation analysis at nuclear research reactor TRR-1.M1. From qualitative analysis of short-lived isotopes, A1, V, Ca, I, Cl, Mn, and Na were found. The quantity of those elements can be classified into three groups. The first group is A1, Ca, Na and Cl with variance less than 10%. The second group is V and I with variance between 10% to 50% and the third group, Mn, two samples have concentration about 12 times higher than the others

  3. Conference on instrumental activation analysis IAA 86

    International Nuclear Information System (INIS)

    Vobecky, M.; Obrusnik, I.

    1986-04-01

    Thirty five papers were presented at the conference held in Klucenice, Czechoslovakia from May 4 to 8, 1986. The abstracts of all papers are printed in the proceedings. The conference discussed the following problem areas: the application of activation analysis in determining elements in ores, tectites, fungi, the thyroid, the primary circuit coolant, semiconductor materials; the application of nuclear reaction analysis in determining elements in rubber and coal; the application of tracer techniques in metallurgy; the description of alpha and gamma spectrometric systems and their testing; the use of microcomputers for data processing, and the description of programs. (J.P.)

  4. Automatization of the neutron activation analysis method in the nuclear analysis laboratory

    International Nuclear Information System (INIS)

    Gonzalez, N.R.; Rivero, D del C.; Gonzalez, M.A.; Larramendi, F.

    1993-01-01

    In the present paper the work done to automatice the Neutron Activation Analysis technic with a neutron generator is described. An interface between an IBM compatible microcomputer and the equipment in use to make this kind of measurement was developed. including the specialized software for this system

  5. Critical reflection activation analysis - a new near-surface probe

    International Nuclear Information System (INIS)

    Gunn, J.M.F.; Trohidou, K.N.

    1988-09-01

    We propose a new surface analytic technique, Critical Reflection Activation Analysis (CRAA). This technique allows accurate depth profiling of impurities ≤ 100A beneath a surface. The depth profile of the impurity is simply related to the induced activity as a function of the angle of reflection. We argue that the technique is practical and estimate its accuracy. (author)

  6. Application of the neutron activation analysis to environmental study

    International Nuclear Information System (INIS)

    Fu Bozhi.

    1995-01-01

    Neutron activation analysis is a nuclear analysis technology. It has been developed in recent times. By this means, the paper analyzes the element contents of leaves, soil and atmospheric dust-fall from the eastern and the western suburbs of Chengdu, then makes a comparison between the two areas and approaches some problems on environmental pollution

  7. Neutron Activation Analysis with k0 Standardization

    International Nuclear Information System (INIS)

    Pomme, S.

    1998-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation aims to: (1) develop and implement k 0 -standardisation method for NAA; (2) to exploit the inherent qualities of NAA such as accuracy, traceability, and multi-element capability; (3) to acquire technical spin-off for nuclear measurements services. Main achievements in 1997 are reported

  8. Use of research reactors for neutron activation analysis. Report of an advisory group meeting

    International Nuclear Information System (INIS)

    2001-04-01

    Neutron activation analysis (NAA) is an analytical technique based on the measurement of characteristic radiation from radionuclides formed directly or indirectly by neutron irradiation of the material of interest. In the last three decades, neutron activation analysis has been found to be extremely useful in the determination of trace and minor elements in many disciplines. These include environmental analysis applications, nutritional and health related studies, geological as well as material sciences. The most suitable source of neutrons for NAA is a research reactor. There are several application fields in which NAA has a superior position compared to other analytical methods, and there are good prospects in developing countries for long term growth. Therefore, the IAEA is making concerted efforts to promote neutron activation analysis and at the same time to assist developing Member States in better utilization of their research reactors. The purpose of the meeting was to discuss the benefits and the role of NAA in applications and research areas that may contribute towards improving utilization of research reactors. The participants focused on five specific topics: (1) Current trends in NAA; (2) The role of NAA compared to other methods of chemical analysis; (3) How to increase the number of NAA users through interaction with industries, research institutes, universities and medical institutions; (4) How to reduce costs and to maintain quality and reliability; (5) NAA using low power research reactors. Neutron activation analysis in its various forms is still active and there are good prospects in developing countries for long-term growth. This can be achieved by a more effective use of existing irradiation and counting facilities, a better end-user focus, and perhaps marginal improvements in equipment and techniques. Therefore, it is recommended that the Member States provide financial and other assistance to enhance the effectiveness of their laboratories

  9. A description of the BNL active surface analysis facility

    International Nuclear Information System (INIS)

    Tyler, J.W.

    1989-11-01

    Berkeley Nuclear Laboratories has a responsibility for the assessment of radioactive specimens arising both from post irradiation examination of power reactor components and structures and experimental programmes concerned with fission and activation product transport. Existing analytical facilities have been extended with the commissioning of an active surface analysis instrument (XSAM 800pci, Kratos Analytical). Surface analysis involves the characterisation of the outer few atomic layers of a solid surface/interface whose chemical composition and electronic structure will probably be different from the bulk. The new instrument consists three interconnected chambers positioned in series; comprising of a high vacuum sample introduction chamber, an ultra-high vacuum sample treatment/fracture chamber and an ultra-high vacuum sample analysis chamber. The sample analysis chamber contains the electron, X-ray and ion-guns and the electron and ion detectors necessary for performing X-ray photoelectron spectroscopy, scanning Auger microscopy and secondary-ion mass spectroscopy. The chamber also contains a high stability manipulator to enable sub-micron imaging of specimens to be achieved and provide sample heating and cooling between - 180 and 600 0 C. (author)

  10. Large Sample Neutron Activation Analysis: A Challenge in Cultural Heritage Studies

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Tzika, F.

    2007-01-01

    Large sample neutron activation analysis compliments and significantly extends the analytical tools available for cultural heritage and authentication studies providing unique applications of non-destructive, multi-element analysis of materials that are too precious to damage for sampling purposes, representative sampling of heterogeneous materials or even analysis of whole objects. In this work, correction factors for neutron self-shielding, gamma-ray attenuation and volume distribution of the activity in large volume samples composed of iron and ceramic material were derived. Moreover, the effect of inhomogeneity on the accuracy of the technique was examined

  11. Thin film analysis by instrumental heavy ion activation analysis using distributed recoil ranges of isotopic products

    International Nuclear Information System (INIS)

    Chowdhury, D.P.; Guin, R.; Saha, S.K.; Sudersanan, M.

    2006-01-01

    Thin foils (0.1 to 10 μm), metallic or polymeric, are frequently used in nuclear physics and chemistry experiments using ion beams from an accelerator. Very often it is important to know the major, minor and trace element composition of the foil. Several nuclear analytical techniques, namely RBS, ERDA, etc. are available for the near surface analysis. We have applied heavy ion activation analysis (HIAA) to explore the bulk composition of thin films. One of the difficulties in this method of thin film analysis is that the product nuclides from nuclear reaction come out of the sample surface due to high recoil energy. In thick sample, the recoiled nuclides are absorbed in the sample itself. This effect has been used to employ heavy ion activation for the analysis of thin films

  12. Utilization and facility of neutron activation analysis in HANARO research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y S; Chung, Y J; Moon, J H [Korea Atomic Energy Research Institute, P.O.Box 105 Yusong, 305-600, Taejon (Korea, Republic of)

    1998-07-01

    The facilities of neutron activation analysis within a multi-purpose research reactor (HANARO) are described and the main applications of Neutron activation analysis (NAA) in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, are installed at three irradiation holes. One irradiation hole is lined with a cadmium tube for epithermal-nal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and polyethylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3.9x10{sup 13}-1.6x10{sup 14} n/cm{sup 2}{center_dot}s and cadmium ratios are 15-250. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Analytical services and the latest analytical results are summarized. (author)

  13. Using Importance-Performance Analysis to Guide Instructional Design of Experiential Learning Activities

    Science.gov (United States)

    Anderson, Sheri; Hsu, Yu-Chang; Kinney, Judy

    2016-01-01

    Designing experiential learning activities requires an instructor to think about what they want the students to learn. Using importance-performance analysis can assist with the instructional design of the activities. This exploratory study used importance-performance analysis in an online introduction to criminology course. There is limited…

  14. Activation analysis using {gamma} photons; Analyse par activation aux photons {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    This report summarizes all the data required for using photonuclear reactions in the field of analysis. After a brief review of the elementary properties of nuclear reactions induced by photon irradiation, the main characteristics are given of high energy (E > 20 MeV) Bremsstrahlung sources. The principle of activation analysis based on the use of photons is given. Actual examples of the analytic possibilities are described in detail, in particular in the case of the determination of very small quantities (< 10{sup -6}) of C, N, O and F. The influence of interfering nuclear reactions is discussed. (author) [French] Ce rapport se propose de resumer l'ensemble des connaissances indispensables pour l'utilisation des reactions photonucleaires a des fins analytiques. Apres quelques rappels concernant les proprietes elementaires des reactions nucleaires induites par irradiation dans les photons, les principales caracteristiques des sources de rayonnement de freinage de haute energie (E > 20 MeV)| sont donnees. Le principe de l'analyse par activation aux photons est rappele. Des exemples concrets sur les possibilites analytiques sont developpes, particulierement en ce qui concerne la determination de quantites tres faibles (< 10{sup -6}) de C, N, O et F. L'influence des reactions nucleaires parasites est discutee. (auteur)

  15. Religious Activities and Suicide Prevention: A Gender Specific Analysis

    Directory of Open Access Journals (Sweden)

    Steven Stack

    2018-04-01

    Full Text Available The present analysis contributes to the existing literature on religion and suicide in three interrelated ways: (1 providing an analysis of suicide completions whereas most research is based on non-lethal levels of suicidality; (2 assessing the relationship with concrete individual level data on completed suicides instead of aggregated data marked by the ecological fallacy issue; and (3 providing gender specific analyses to determine if the relationship is gendered. METHODS. Data come from the U.S. Public Health Service, National Mortality Followback Survey. They refer to 16,795 deaths including 1385 suicides. Significant others of the deceased were interviewed to measure all variables. The dependent variable is a binary variable where 1 = death by suicide and 0 = all other causes. The central independent variable is an index of religious activities. Controls are included for five categories of confounders (1 psychiatric morbidity; (2 help-seeking behavior; (3 Opportunity factors such as firearms; (4 social integration; and (5 demographics. RESULTS. Multivariate logistic regression analysis determined that controlling for 16 predictors of suicide, a one unit increase in religious activities reduced the odds of a suicide death by 17% for males and by 15% for females. The difference in coefficients is not significant (Z = 0.51. Other significant predictors of suicide deaths included suicide ideation (OR = 8.87, males, OR = 11.48, females and firearm availability (OR = 4.21, males, OR = 2.83, females. DISCUSSION. Religious activities were found to lower suicide risk equally for both men and women. Further work is needed to assess pathways, including suicide ideation, between religious activities and lowered suicide risk. This is the first U.S. based study to test for a gendered association between religion and suicide at the individual level of analysis.

  16. Uncommon evolution of probable central nervous system histoplasmosis: from leptomeningitis to posterior fossa granuloma. A case report with magnetic resonance images

    International Nuclear Information System (INIS)

    Carrilho, Paulo Eduardo Mestrinelli; Alves, Orival

    2006-01-01

    We report a case of a young immunocompetent patient with probable central nervous system histoplasmosis with evolutive peculiar findings seen on magnetic resonance imaging. Leptomeningeal thickening was initially observed which subsequently became a posterior fossa granuloma. The diagnosis of fungal infection was only reached by histopathological study and the treatment was based on long term therapy with fluconazole wth good initial response. (author)

  17. Uncommon evolution of probable central nervous system histoplasmosis: from leptomeningitis to posterior fossa granuloma. A case report with magnetic resonance images; Evolucao incomum de provavel histoplasmose de sistema nervoso central: de leptomeningite para granuloma da fossa posterior. Relato de caso com imagens por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Carrilho, Paulo Eduardo Mestrinelli; Alves, Orival [Universidade Estadual do Oeste do Parana - UNIOESTE, Cascavel, PR (Brazil). Curso de Medicina. Disciplina de Neurologia e Neurocirurgia]. E-mail: carrilho@certto.com.br; Budant, Manfredo [UNITOM - Unidade de Diagnostico por Imagem, Cascavel, PR (Brazil). Centro de Tomografia; Bozo, Marlon K.; Meirelles, Noel [Universidade Estadual do Oeste do Parana - UNIOESTE, Cascavel, PR (Brazil). Curso de Medicina; Bueno, Alexandre Galvao [ANATOM - Instituto de Anatomia Patologica de Cascavel, PR (Brazil)

    2006-01-15

    We report a case of a young immunocompetent patient with probable central nervous system histoplasmosis with evolutive peculiar findings seen on magnetic resonance imaging. Leptomeningeal thickening was initially observed which subsequently became a posterior fossa granuloma. The diagnosis of fungal infection was only reached by histopathological study and the treatment was based on long term therapy with fluconazole wth good initial response. (author)

  18. Antiglycation and Antioxidant Activities and HPTLC Analysis of ...

    African Journals Online (AJOL)

    Furthermore, high performance thin layer chromatography (HPTLC) analysis of Boswellia sacra resins was also carried out. Results: Polar fractions of the extract obtained exhibited the highest antiglycation activity while nonpolar fractions showed more than 50 % inhibition in superoxide anion scavenging assay.

  19. Vanadium determination in pretoleum by neutron activation analysis

    International Nuclear Information System (INIS)

    Lopez, M.; Espinosa, R.

    1983-01-01

    The vanadium concentration in an Peruvian petroleum sample is determined by neutron activation analysis. The samples were irradiated for 20 minutes with a flux of thermal neutrons of 1.75 x 10 7 n/cm 2 -s in a subcritical assembly. The activity of the created samples decreases to half 15 minutes after the irradiation. The result is 28.3 +- 0.8 p.p.m. with a typical deviation of 2.8%. The detection limit of this method is 4 p.p.m

  20. Estimation of 129I by low energy spectrometry and neutron activation analysis

    International Nuclear Information System (INIS)

    Ravi, P.M.; Iyer, M.R.; Sahasrabudhe, S.G.; Somasundaram, S.; Subramanian, M.S.

    1986-01-01

    Methods have been developed for the estimation of 129 I by direct passive counting and by neutron activation analysis. The direct counting method using low energy photon spectrometry has been standardised for liquid samples. Interference from different induced radionuclides in the activation method was studied. Limits of detection of 129 I by direct counting method and neutron activation analysis work out to be 0.4 Bq and 1mBq respectively. (author). 6 refs

  1. Mediation analysis of the relationship between institutional research activity and patient survival

    DEFF Research Database (Denmark)

    Rochon, Justine; du Bois, Andreas; Lange, Theis

    2014-01-01

    BACKGROUND: Recent studies have suggested that patients treated in research-active institutions have better outcomes than patients treated in research-inactive institutions. However, little attention has been paid to explaining such effects, probably because techniques for mediation analysis...... existing so far have not been applicable to survival data. METHODS: We investigated the underlying mechanisms using a recently developed method for mediation analysis of survival data. Our analysis of the effect of research activity on patient survival was based on 352 patients who had been diagnosed...... mediated through either optimal surgery or chemotherapy. Taken together, about 26% of the beneficial effect of research activity was mediated through the proposed pathways. CONCLUSIONS: Mediation analysis allows proceeding from the question "Does it work?" to the question "How does it work?" In particular...

  2. Some Applications of Fast Neutron Activation Analysis of Oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Owrang, Farshid

    2003-07-01

    illustrated how the activated water would propagate along that pipe. C) Combustion products. In order to investigate the oxidation in combustion products (deposits), the total amount of oxygen in the deposits collected from combustion chambers of a modern gasoline engine was measured, using cyclic fast neutron activation analysis (FNAA). As a compartment, the organic compounds containing oxygen were identified using {sup 13}C solid-state nuclear magnetic resonance (NMR) spectroscopy. The results of FNAA showed that the amount of oxygen in deposits varies depending on where the deposits have been formed. {sup 13}C NMR has showed that the carbon backbone of the deposits exists as highly oxidized poly aromatics and/or graphitic structure. D) On-line fast neutron activation analysis. On-line neutron activation analysis was used to detect the amount of oxygen in bulk liquids. The method was optimised for on-line detection of oxygen in rapeseed oil. The goal was to develop a non-intrusive method for measurement of the total amount of oxygen in oil during combustion/oxidation.

  3. Some Applications of Fast Neutron Activation Analysis of Oxygen

    International Nuclear Information System (INIS)

    Owrang, Farshid

    2003-01-01

    illustrated how the activated water would propagate along that pipe. C) Combustion products. In order to investigate the oxidation in combustion products (deposits), the total amount of oxygen in the deposits collected from combustion chambers of a modern gasoline engine was measured, using cyclic fast neutron activation analysis (FNAA). As a compartment, the organic compounds containing oxygen were identified using 13 C solid-state nuclear magnetic resonance (NMR) spectroscopy. The results of FNAA showed that the amount of oxygen in deposits varies depending on where the deposits have been formed. 13 C NMR has showed that the carbon backbone of the deposits exists as highly oxidized poly aromatics and/or graphitic structure. D) On-line fast neutron activation analysis. On-line neutron activation analysis was used to detect the amount of oxygen in bulk liquids. The method was optimised for on-line detection of oxygen in rapeseed oil. The goal was to develop a non-intrusive method for measurement of the total amount of oxygen in oil during combustion/oxidation

  4. Physical Activity and Cognitive Development: A Meta-Analysis.

    Science.gov (United States)

    Jackson, William M; Davis, Nicholas; Sands, Stephen A; Whittington, Robert A; Sun, Lena S

    2016-10-01

    Is there an association between regular exercise, defined as a structured program of increased physical activity at least 1 month in duration, and improvements in measures of executive functions compared with children who engage in their normal daily activities? The association between increased physical activity and changes in performance on tasks of executive functions have not been well elucidated in children. Executive functioning is important to intellectual development and academic success in children, and inexpensive, nonpharmacological methods for the treatment of executive dysfunction represent an attractive interventional target. To estimate the effect of a structured regular exercise program on neuropsychological domains of executive function in children ages 7 to 12. We performed a systematic review of English and non-English articles using Cochrane Library, EBSCO CINAHL, Ovid MEDLINE, PSYCInfo, Pubmed, and Web of Science, including all years allowed by each individual search engine. The search string used was "(exercise OR phys*) AND (cognit* OR executive) AND (child* OR preadolesc*)." The authors of the studies selected for review were contacted for any unpublished data. Randomized controlled trials, which enrolled children between the ages of 7 and 12, with randomization to either normal activity or a structured physical activity intervention consisting of scheduled aerobic exercise, at least once per week, for a period of at least 1 month. Eligible studies must have included a neuropsychological battery of tests that measured at least 1 executive function both before and after the intervention was completed. Two independent reviewers examined the screened studies in detail for potential inclusion. The results of the individual examinations were compared; if any discrepancies were present, a third party analyzed the study to determine if it should be included in the meta-analysis. A total of 18 studies were identified by abstract as candidates for

  5. Neutron activation analysis of monomineral fractions

    International Nuclear Information System (INIS)

    Drykhin, V.I.; Belen'kij, B.V.; Voinkov, D.M.; Il'yasova, K.I.; Lejpinskaya, D.I.; Nedostyp, T.V.

    1977-01-01

    The results are described of the development of an instrumental neutron activation analysis (INAA) of monomineral sulfides (pyrites, pyrrhotites, chalcopyrites and others), quartzites and other minerals, the technique being intended for geochemical investigations. For a multi-element INAA of monomineral sulfides, the optimum irradiation time in a flux of 10 12 to 1.3x10 13 n/cm 2 (neutron field of a nuclear reactor) is 20 to 40 hours, thus ensuring a reliable determination of a great number of elements not lower than 10 -4 %. The time of the induced activity for determining indium in sulfides is 0.5 to 3 min. The actual sensitivity of the method is 10 -4 %. A sensitivity with respect to gold of 0.01 g/t was attained in monominerals after an irradiation of up to 5 min

  6. Selected industrial and environmental applications of neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.

    1999-01-01

    A review of the applications of Instrumental Neutron Activation Analysis (INAA) in the industrial and environmental fields is given. Detection limits for different applications are also given. (author)

  7. Instrumental neutron activation analysis of soil sample

    International Nuclear Information System (INIS)

    Abdul Khalik Haji Wood.

    1983-01-01

    This paper describes the analysis of soil samples collected from 5 different location around Sungai Lui, Kajang, Selangor, Malaysia. These sample were taken at 22-24 cm from the top of the ground and were analysed using the techniques of Instrumental Neutron Activation Analysis (INAA). The analysis on soil sample taken above 22-24 cm level were done in order to determine if there is any variation in elemental contents at different sampling levels. The results indicate a wide variation in the contents of the samples. About 30 elements have been analysed. The major ones are Na, I, Cl, Mg, Al, K, Ti, Ca and Fe. Trace elements analysed were Ba, Sc, V, Cr, Mn, Ga, As, Zn, Br, Rb, Co, Hf, Zr, Th, U, Sb, Cs, Ce, Sm, Eu, Tb, Dy, Yb, Lu and La. (author)

  8. Analysis of atmospheric particulate samples via instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Greenberg, R.R.

    1990-01-01

    Instrumental neutron activation analysis (INAA) is a powerful analytical technique for the elemental characterization of atmospheric particulate samples. It is a true multielement technique with adequate sensitivity to determine 30 to 40 elements in a sample of atmospheric particulate material. Its nondestructive nature allows sample reanalysis by the same or a different analytical technique. In this paper as an example of the applicability of INAA to the study of atmospheric particulate material, a study of the emissions from municipal incinerators is described

  9. Examples of analysis by activation; Exemples d'analyse par activation

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    We were used various nuclear reactions to do some analysis by neutron or by X-ray activation. We used the french reactor core Zoe as neutrons sources and an Allis-Chalmers betatron as X-rays sources for the dosage of the light elements. The described processes were revealed fast and particularly useful for determination of traces. The fact that most of them don't require any chemical operations, is especially substantial when the solubilization of the sample is difficult. (M.B.) [French] Nous avons utilise des reactions nucleaires diverses pour effectuer des analyses par activation neutronique ou par rayon X. Nous avons utilise la pile francaise Zoe comme sources de neutrons et un betatron Allis-Chalmers comme sources de rayons X pour le dosage des elements legers. Les procedes decrits se sont reveles rapides et particulierement utiles dans la determination des traces. Le fait que, pour la plupart, ils n'exigent pas d'operations chimiques, est particulierement appreciable lorsque la solubilisation des echantillons est difficile. (M.B.)

  10. Altered sensorimotor activation patterns in idiopathic dystonia-an activation likelihood estimation meta-analysis of functional brain imaging studies

    DEFF Research Database (Denmark)

    Løkkegaard, Annemette; Herz, Damian M; Haagensen, Brian Numelin

    2016-01-01

    Dystonia is characterized by sustained or intermittent muscle contractions causing abnormal, often repetitive, movements or postures. Functional neuroimaging studies have yielded abnormal task-related sensorimotor activation in dystonia, but the results appear to be rather variable across studies....... Further, study size was usually small including different types of dystonia. Here we performed an activation likelihood estimation (ALE) meta-analysis of functional neuroimaging studies in patients with primary dystonia to test for convergence of dystonia-related alterations in task-related activity...... postcentral gyrus, right superior temporal gyrus and dorsal midbrain. Apart from the midbrain cluster, all between-group differences in task-related activity were retrieved in a sub-analysis including only the 14 studies on patients with focal dystonia. For focal dystonia, an additional cluster of increased...

  11. Multi trace element analysis of dry biological materials by neutron activation analysis including a chemical group separation

    International Nuclear Information System (INIS)

    Weers, C.A.

    1980-07-01

    Multi-element analysis of dry biological material by neutron activation analysis has to include radiochemical separation. The evaporation process is described in terms of the half-volume. The pretreatment of the samples and the development of the destruction-evaporation apparatus are described. The successive adsorption steps with active charcoal, Al 2 O 3 and coprecipitation with Fe(OH) 3 are described. Results obtained for standard reference materials are summarized. (G.T.H.)

  12. Applying an Activity System to Online Collaborative Group Work Analysis

    Science.gov (United States)

    Choi, Hyungshin; Kang, Myunghee

    2010-01-01

    This study determines whether an activity system provides a systematic framework to analyse collaborative group work. Using an activity system as a unit of analysis, the research examined learner behaviours, conflicting factors and facilitating factors while students engaged in collaborative work via asynchronous computer-mediated communication.…

  13. Spatiotemporal Data Mining, Analysis, and Visualization of Human Activity Data

    Science.gov (United States)

    Li, Xun

    2012-01-01

    This dissertation addresses the research challenge of developing efficient new methods for discovering useful patterns and knowledge in large volumes of electronically collected spatiotemporal activity data. I propose to analyze three types of such spatiotemporal activity data in a methodological framework that integrates spatial analysis, data…

  14. 'ACTIV' - a package of codes for charged particle and neutron activation analysis

    International Nuclear Information System (INIS)

    Cincu, Em.; Alexandreanu, B.; Manu, V.; Moisa, V.

    1997-01-01

    The 'ACTIV' Program is an advanced software package dedicated to applications of the thermal neutron and charged particle activation (NAA and CPA) induced reactions. The program is designed to run on personal computers compatible IBM PC-Models XT/AT, 286 or more advanced, operating under DOS version 5.0 or later, on systems with minimum 5 MB of hard disk memory. The package consists of 6 software modules and a Nuclear Data Base comprising physical, nuclear reaction and decay data for: thermal neutron, proton, deuteron and α-particle induced reactions on 15 selected metallic elements; the nuclear reaction data corresponds to the energy range (5-100) MeV. In the first version - ACTIV 1.0 - the set of input data concerns: the sample type, irradiation and measurement conditions, the γ-ray spectrum identification code, selected detection efficiency calibration curve, selected radionuclides, selected standardization method for elemental analysis, version of results. At present, the 'ACTIV' package comprises 6 soft modules for processing the experimental data, which ensure computation of the quantities: radionuclide activities, activation yield data (case of CPA) and elemental concentration by relative and absolute standardization methods. Recently, the software designed to processing complex γ-ray spectra was acquired and installed on our PC 486 (8 MB RAM, 100 MHz). The next step in developing the 'ACTIV' program envisages improving the existing computing codes, completing the data libraries, incorporating a new soft for the direct use of the 'Quantum TM MCA' data, developing modules dedicated to uncertainty computation and optimization of the activation experiments

  15. Toenail elemental analysis of Korean young adults by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lee, O.

    2016-01-01

    The element contents in toenail clippings of healthy Korean young adults were measured using an instrumental neutron activation analysis. The average contents of elements such as Na, K, Cl, Ca, Fe, Se, and Zn are 449, 474, 1024, 1677, 66, 0.7 and 94 mg/kg in men, whereas those contents in women respectively 332, 476, 836, 1097, 66, 0.8 and 104 mg/kg. The correlation analysis of toenail elements with chronic disease risks showed positive associations between Na and serum HDL-cholesterol, blood pressure, and negative associations between Se and Hs-CRP, between Zn and hemoglobin level. (author)

  16. Cluster analysis of activity-time series in motor learning

    DEFF Research Database (Denmark)

    Balslev, Daniela; Nielsen, Finn Årup; Frutiger, Sally A.

    2002-01-01

    Neuroimaging studies of learning focus on brain areas where the activity changes as a function of time. To circumvent the difficult problem of model selection, we used a data-driven analytic tool, cluster analysis, which extracts representative temporal and spatial patterns from the voxel...... practice-related activity in a fronto-parieto-cerebellar network, in agreement with previous studies of motor learning. These voxels were separated from a group of voxels showing an unspecific time-effect and another group of voxels, whose activation was an artifact from smoothing. Hum. Brain Mapping 15...

  17. Time regimes optimization of the activation-measurement cycle in neutron activation analysis

    International Nuclear Information System (INIS)

    Szopa, Z.

    1986-01-01

    Criteria of the optimum time conditions of the activation-measurement cycle in neutron activation analysis have been formulated. The optimized functions i.e. the relative precision or the factor of ''merit'' of the analytical signal measured as functions of the cycle time parameters have been proposed. The structure and possibilities of the optimizing programme STOPRC have been presented. This programme is completely written in FORTRAN and takes advantage of the library of standard spectra and fast, stochastic algorithms. The time conditions predicted with the aid of the programme have been discussed and compared with the experimental results for the case of the determination of tungsten in industrial dusts. 31 refs., 4 figs. (author)

  18. Study of interference by double neutron capture in activation analysis

    International Nuclear Information System (INIS)

    Cohen, I.M.; Korob, R.O.; Mila, M.I.; Rocca, H.C.

    1976-06-01

    The characteristics of the interferences by double capture in activation analysis are studied. Calculations of these interferences are performed, based on the corresponding activation functions, for typical irradiation and decay times. The experiments performed with the pairs Ho-Dy and Pt-Au and their results are commented. (author) [es

  19. Microbiological Analysis of an Active Pilot-Scale Mobile Bioreactor Treating Organic Contaminants

    International Nuclear Information System (INIS)

    Brigmon, R.L.

    1997-01-01

    Samples were obtained for microbiological analysis from a granular activated carbon fluidized bed bioreactor (GAC-FBR). This GAC-FBR was in operation at a former manufactured gas plant (MGP) Site in Augusta Georgia for in situ groundwater bioremediation of organics. The samples included contaminated site groundwater, GAC-FBR effluent, and biofilm coated granular activated carbon at 5, 9, and 13 feet within the GAC-FBR column. The objective of this analysis was to correlate contaminant removal with microbiological activity within the GAC-FBR

  20. The holistic analysis of gamma-ray spectra in instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Blaauw, M

    1993-11-15

    The subject is the computerized analysis of the gamma-ray spectra in INAA. This analysis can be separated in three parts: The conversion of the spectra to information on {gamma}-ray energies and their relative intensities (spectrum reduction), the determination of the relation between the intensity of a {gamma}-ray and the amount of the corresponding element present in the sample (standardization) and the attribution of the {gamma}-ray energies to the elements, including the subsequent computation of the amounts of the elements (interpretation). A {gamma}-ray spectrum can be considered to be the linear sum of the {gamma}-ray spectra of the individual radionuclides present in the sample. Knowing the relative activities of the different radionuclides that may be produced by activation of a single element, a {gamma}-ray spectrum in INAA can also be considered to be the linear sum of the spectra of the elements. This principle has hitherto not been used in INAA to analyze the spectra by linear least squares methods, using all {gamma}-ray energies observed in the spectrum. The implementation of this `holistic` approach required that attention be paid to both spectrum reduction, standardization and interpretation. The thesis describes the methods developed for the holistic analysis of {gamma}-ray spectra in INAA, and present results of experimental comparisons between the holistic and other approaches. (orig./HP).

  1. The holistic analysis of gamma-ray spectra in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Blaauw, M.

    1993-01-01

    The subject is the computerized analysis of the gamma-ray spectra in INAA. This analysis can be separated in three parts: The conversion of the spectra to information on γ-ray energies and their relative intensities (spectrum reduction), the determination of the relation between the intensity of a γ-ray and the amount of the corresponding element present in the sample (standardization) and the attribution of the γ-ray energies to the elements, including the subsequent computation of the amounts of the elements (interpretation). A γ-ray spectrum can be considered to be the linear sum of the γ-ray spectra of the individual radionuclides present in the sample. Knowing the relative activities of the different radionuclides that may be produced by activation of a single element, a γ-ray spectrum in INAA can also be considered to be the linear sum of the spectra of the elements. This principle has hitherto not been used in INAA to analyze the spectra by linear least squares methods, using all γ-ray energies observed in the spectrum. The implementation of this 'holistic' approach required that attention be paid to both spectrum reduction, standardization and interpretation. The thesis describes the methods developed for the holistic analysis of γ-ray spectra in INAA, and present results of experimental comparisons between the holistic and other approaches. (orig./HP)

  2. Toxicological applications of neutron-activation analysis

    International Nuclear Information System (INIS)

    Cross, J.D.; Dale, I.M.; Smith, H.

    1975-01-01

    Thermal neutron-activation analysis is recognised as a useful tool for trace element studies in toxicology. This paper describes some recent applications of the technique to three elements when ingested by people in excess of normal intake Two of the elements (copper and chromium) are essential to life and one (bromine) is as yet unclassified. Three deaths were investiagted and trace element levels compared with normal levels from healthy subjects in the same geographical area who had died as a result of violence. (author)

  3. A survey of social media data analysis for physical activity surveillance.

    Science.gov (United States)

    Liu, Sam; Young, Sean D

    2018-07-01

    Social media data can provide valuable information regarding people's behaviors and health outcomes. Previous studies have shown that social media data can be extracted to monitor and predict infectious disease outbreaks. These same approaches can be applied to other fields including physical activity research and forensic science. Social media data have the potential to provide real-time monitoring and prediction of physical activity level in a given region. This tool can be valuable to public health organizations as it can overcome the time lag in the reporting of physical activity epidemiology data faced by traditional research methods (e.g. surveys, observational studies). As a result, this tool could help public health organizations better mobilize and target physical activity interventions. The first part of this paper aims to describe current approaches (e.g. topic modeling, sentiment analysis and social network analysis) that could be used to analyze social media data to provide real-time monitoring of physical activity level. The second aim of this paper was to discuss ways to apply social media analysis to other fields such as forensic sciences and provide recommendations to further social media research. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  4. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Fischer, E.

    1976-05-01

    A neutron activation method for multielement determination in biological material was developed. The individual steps of the method include radiochemical processing as well as nondestructive techniques. In order to develop a high resolution gamma spectrometric method the indispensable assumptions were the application of Ge(Li)-semiconductor detectors, multi-channel pulse height analyzers and the use of electronic data evaluation with mini-computers for the automatic evaluation of complex gamma spectra. After radiochemical separation (RNAA) 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements is 4 days. The neutron activation method is used routinely for the determination of trace elements in foodstuffs and in the field of nutrition research. (orig.) [de

  5. Analysis of traces at ORNL's new high-flux neutron activation laboratory

    International Nuclear Information System (INIS)

    Ricci, E.; Handley, T.H.; Dyer, F.F.

    1974-01-01

    The investigations are outlined, which are carried out in order to develop (preferably instrumental) methods for multielement analysis of various trace elements. For this reason a new High-Flux NAA Laboratory was constructed at ORNL's. A general review is given on the Laboratory, further some methods and applications are shown. In the field of comparator activation analysis comparative data are given on mercury determinations in various matrices, and on arsenic determination in grasshoppers. This later method was used to trace the transport of arsenic containing pesticides. Some data are given on absolute activation analysis of Na, Ci, Mn, Br, and Au, too. (K.A.)

  6. SWAN - Detection of explosives by means of fast neutron activation analysis

    International Nuclear Information System (INIS)

    Gierlik, M.; Borsuk, S.; Guzik, Z.; Iwanowska, J.; Kaźmierczak, Ł.; Korolczuk, S.; Kozłowski, T.; Krakowski, T.; Marcinkowski, R.; Swiderski, L.; Szeptycka, M.; Szewiński, J.; Urban, A.

    2016-01-01

    In this work we report on SWAN, the experimental, portable device for explosives detection. The device was created as part of the EU Structural Funds Project “Accelerators & Detectors” (POIG.01.01.02-14-012/08-00), with the goal to increase beneficiary's expertise and competencies in the field of neutron activation analysis. Previous experiences and budged limitations lead toward a less advanced design based on fast neutron interactions and unsophisticated data analysis with the emphasis on the latest gamma detection and spectrometry solutions. The final device has been designed as a portable, fast neutron activation analyzer, with the software optimized for detection of carbon, nitrogen and oxygen. SWAN's performance in the role of explosives detector is elaborated in this paper. We demonstrate that the unique features offered by neutron activation analysis might not be impressive enough when confronted with practical demands and expectations of a generic homeland security customer.

  7. In Vitro Analysis of Antioxidant Activities of Oxalis Corniculata Linn ...

    African Journals Online (AJOL)

    In Vitro Analysis of Antioxidant Activities of Oxalis Corniculata Linn. Fractions in Various Solvents. D Ahmed, S Zara, H Baig. Abstract. As part of our search for natural antioxidants, this work presents an evaluation of antioxidant activities of methanolic extract of Oxalis corniculata and its sub-fractions in hexane, chloroform, ...

  8. Analysis by nuclear reactions and activations. A current bibliography

    International Nuclear Information System (INIS)

    Bujdoso, E.

    2001-01-01

    A current bibliography based on INIS Atomindex with 78 references on Analysis by nuclear reactions and activations has been prepared for year 1998. References are arranged by first authors' name. (N.T.)

  9. Analysis of 137Cs radionuclides activities in Cs-zeolite using gamma spectrometry

    International Nuclear Information System (INIS)

    Noviarty; Ginting, Aslina Br; Anggraini, Dian; Rosika K

    2013-01-01

    137 Cs Radionuclide activity analysis has been carried out. The objective is to determine the activity of the 137 Cs radionuclide in Cs-zeolite are packaged in the form of point source. Analysis of 137 Cs Radionuclide activities in Cs zeolite samples was determined by measuring intensity of the isotope 137 Cs gamma energy at 661.7 keV use-y spectrometer. Before measurement the sample, was first carried out measurements of 137 Cs radionuclide in certified point standards from Amersham, to determine the efficiency value. Result the standard sample measurement obtained the efficiency value of 43.98%. Efficiency values obtained are used in the calculation of sample activity. On the measurement of the intensity of the sample obtained results dose rate 196.4537 cps with a standard deviation of 0.5274. By using standard measurement efficiency values obtained by the calculation of the average activity of the radionuclide 137 Cs in Cs-zeolite 524.9082 Bq. Deviation measurements were below 5% (0.27% ) so that the analysis of the activity of radionuclide 137 Cs in Cs-zeolite samples using gamma spectrometer can be accepted with a 95% confidence level. (author)

  10. Mapping of brain activity by automated volume analysis of immediate early genes

    Science.gov (United States)

    Renier, Nicolas; Adams, Eliza L.; Kirst, Christoph; Wu, Zhuhao; Azevedo, Ricardo; Kohl, Johannes; Autry, Anita E.; Kadiri, Lolahon; Venkataraju, Kannan Umadevi; Zhou, Yu; Wang, Victoria X.; Tang, Cheuk Y.; Olsen, Olav; Dulac, Catherine; Osten, Pavel; Tessier-Lavigne, Marc

    2016-01-01

    Summary Understanding how neural information is processed in physiological and pathological states would benefit from precise detection, localization and quantification of the activity of all neurons across the entire brain, which has not to date been achieved in the mammalian brain. We introduce a pipeline for high speed acquisition of brain activity at cellular resolution through profiling immediate early gene expression using immunostaining and light-sheet fluorescence imaging, followed by automated mapping and analysis of activity by an open-source software program we term ClearMap. We validate the pipeline first by analysis of brain regions activated in response to Haloperidol. Next, we report new cortical regions downstream of whisker-evoked sensory processing during active exploration. Lastly, we combine activity mapping with axon tracing to uncover new brain regions differentially activated during parenting behavior. This pipeline is widely applicable to different experimental paradigms, including animal species for which transgenic activity reporters are not readily available. PMID:27238021

  11. Neutron-activation analysis of trace elements in thyroids

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Petri, H.; Kanash, N.V.; Malenchenko, A.F.

    1999-01-01

    Neutron activation analysis was used for routine measurement of trace elements in thyroids of inhabitants of Belarus as well as in thyroids of people operated for thyroid cancer. The method chosen allowed the analysis of 28 elements, among them essential and toxic ones, with a good accuracy. The results obtained showed significant differences in the elemental composition of thyroid from the different regions. The changes of elemental composition of thyroids of inhabitants of the Gomel region, where goiter is endemic, seem to be identical to those in the tumor tissue. (author)

  12. Capability Study For Using the Impulse Graphite Reactor For Activation Analysis of Geological Materials

    International Nuclear Information System (INIS)

    Azarov, V.A.; Silaev, M.E.

    1998-01-01

    The IGR reactor facility available in the Institute of Atomic Energy NNC RK is mainly used for testing the going and newly developed fuel compositions and reactor materials. In connection with a decrease of the demand in investigations like that there was considered the capability to use the reactor for solving another research and, particularly, applied problems. A mineral exploration is one of the urgent objectives in the Republic of Kazakstan, and in Semipalatinsk region in particular. To perform the exploration like that it's required, in addition to rough field investigations, the methods of analysis for element composition of geological materials, the difference of which is in their effectiveness, quality and low first cost. Activation methods of analysis allow to provide with a high analysis quality and effectiveness. Therefore, there was proposed to study the capability to use the IGR reactor for the activation analysis of geological materials. To solve this goal the following activity in three basic trends is required: 1. To create the needed theoretical and, on its basis, the methodical base for performing the analytical activity; 2. To create the experimental and technical and organizational infrastructure for the investigations, providing with a high productivity and low prime cost of work; 3. To conduct works on marketing and to use the going methodical and technical base on the market of services. Major objectives for the creation of the theoretical and methodical base for analysis are: a) the study of neutron and physical IGR reactor characteristics under various operation modes; b) the study of the radiation effect on the results of activation analysis; c) the simulation of the temperature mode for irradiation of samples in the reactor and experimental model survey; d) the study of the capability to use non-traditional elements and materials as neutron reactor flux monitors; e) the development of the technique for the experimental and computational

  13. Industrial applications of neutron activation analysis

    International Nuclear Information System (INIS)

    Hossain, T.Z.

    2001-01-01

    Neutron activation analysis has been widely used in the industry and over the years played a key role in the development of manufacturing process as well as monitoring of the process flow. In this context NAA has been utilized both in R and D, and in the factory as a flexible analytical tool. It has been used successfully in numerous industries including broad categories such as Chemical, Pharmaceutical, Mining, Photographic, Oil and Gas, Automobile, Defense, Semiconductor and Electronic industries. Dow Chemical owns and operates a research reactor for analytical measurements of samples generated in both R and D, and manufacturing area in its plant in Midland, Michigan. Although most industries do not have reactors on their campus but use an off site reactor regularly, and often have in-house neutron sources such as a 252 Cf used primarily for NAA. In most industrial materials analysis laboratory NAA is part of a number of analytical techniques such as ICP-MS, AA, SIMS, FTIR, XRF, TXRF etc. Analysis of complex industrial samples may require data from each of these methods to provide a clear picture of the materials issues involved. With the improvement of classical analytical techniques, and the introduction of new techniques, e.g. TXRF, the role of NAA continues to be a key bench mark technique that provides accurate and reliable data. The strength of the NAA in bulk analysis is balanced by its weakness in providing surface sensitive or spatially resolved analysis as is required by many applications. (author)

  14. Application of neuro-fuzzy model for neutron activation analysis (NAA)

    International Nuclear Information System (INIS)

    Khalafi, H.; Terman, M.S.; Rahmani, F.

    2011-01-01

    Neutron activation analysis (NAA) is a precise chemical multielemental method of analysis which is satisfactorily used for qualitative and quantitative analyses. Repeated irradiation is needed because of mal-determination of some elements due to peak overlap in qualitative analysis. In this study, NAA procedure has been modified using a neuro-fuzzy model to avoid repeated irradiation based on multilayer perceptrons network trained by the Levenberg Marquardt algorithm. This method increases the precision of spectrum analysis in the case of strong background and peak overlap. (authors)

  15. Analysis of medicinal plant extracts by neutron activation method

    International Nuclear Information System (INIS)

    Vaz, Sandra Muntz

    1995-01-01

    This dissertation has presented the results from analysis of medicinal plant extracts using neutron activation method. Instrumental neutron activation analysis was applied to the determination of the elements Al, Br, Ca, Ce, Cl, Cr, Cs, Fe, K, La, Mg, Mn, Na, Rb, Sb, Sc and Zn in medicinal extracts obtained from Achyrolcline satureoides DC, Casearia sylvestris, Centella asiatica, Citrus aurantium L., Solano lycocarpum, Solidago microglossa, Stryphnondedron barbatiman and Zingiber officinale R. plants. The elements Hg and Se were determined using radiochemical separation by means of retention of Se in HMD inorganic exchanger and solvent extraction of Hg by bismuth diethyl-dithiocarbamate solution. Precision and accuracy of the results have been evaluated by analysing reference materials. The therapeutic action of some elements found in plant extracts analyzed was briefly discussed

  16. Low-level dosimetry based on activation analysis of badge film, 1

    International Nuclear Information System (INIS)

    Morikawa, Kaoru; Yamashita, Kazuya; Inamoto, Kazuo; Maeda, Masayuki; Sato, Takashi; Ono, Koichi.

    1988-01-01

    Underexposed badge film contains a minor quantity of silver which corresponds to the low radiation dose even after completion of the photographic densitometry ; however, it cannot be detected with a photographic densitometer. We intended to clarify the minor silver content based on radioactivation analysis with thermal neutrons at KUR (Kyoto University Research Reactor). The natural silver consists of two stable nuclides, i.e., 107 Ag and 109 Ag. These can be activated with irradiation of thermal neutrons to two radionuclides, i.e., 108 Ag and 110 Ag. In this paper, through the activation analysis of an underexposed badge film, methods of measurements are shown regarding both 108 Ag produced by the 107 Ag (n, γ) reaction and 110 Ag by the 109 Ag (n, γ). After underexposed badge films were irradiated with thermal neutrons, some gamma-rays emitted from the radionuclides in the activated films were measured with a high pure Ge detector or a NaI (Tl) scintillation detector. The following results were obtained: (1) several elements such as silver, iodine, gold, antimony, manganese and copper were detected by activation analyses of films exposed to low level 60 Co gamma-rays, (2) the exposure vs 108 Ag or 110 Ag activity curve was linear in the lower dose range of 60 Co gamma-rays. These data indicate that low level radiation doses, which is indeterminable by ordinary photographic densitometry, can be estimated by activation analysis of silver atoms in badge films. (author)

  17. Instrumental neutron activation analysis in environmental research

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1985-01-01

    The main characteristics of instrumental neutron activation analysis (INAA),relevant for environmental research and monitoring, was reviewed and discussed-sensitivity, suitable for detection of many toxic elements, the low risks of contamination of element loss, lack of matrix effects, lack of light element interference except for 24 Na, capability for multi-element determination, comparatively low costs. A detailed description of the IRI analysis system for routine INAA is given. The system is based on the single comparator method of standartization to take full advantage of multi-element without preparation and use the trace element standards. Zinc was used as mono element standard, the element concentrations are calculated on the basis of 65 Zn and 69m Zn-activities. The irradiations were carried out in a thermal neutron flux of 1.10 13 n/cm 2 .s. The gamma spectra is converted into element concentrations using a set of dedicated software, performing the following functions: spectrum analysis and interpretation, comparison and combination of the intermediate results from different decay times, generation of the final report, bookkeeping of the results obtained. The main applications of the INAA system mentioned are: identification of sources of heavy metal air pollution using air filters or biological indicators such as mosses, lichens, toe-nails, bird feathers, molusks and waterplants; and study of the uptake and translocation of heavy element in plants. Special attention was paid to mathematical techniques for a reliable interpretation of the element concentration patterns observed in sets of lichen samples. Future developments in INAA in environmental science are briefly mentioned

  18. Comparative study of destructive and non-destructive methods in the activation analysis of rocks

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.

    1978-01-01

    A comparative study between non-destructive thermal neutron activation analysis and activation analysis with radiochemical group separation is made Both methods are applied to the determination of trace elements minor and major elements in rocks. The treatment of the rocks, with special reference to the problems related to grinding and contamination by foreign elements is described. The choice of standards for multielement trace activation analysis is discussed. Two types of computer programs for the evalution of data obtained through Ge-li detector counting are used. All the phases of the destructive and non destructive analysis are described. In the destructive analysis, an adaptation of the group separation scheme developed by Morrison et al for the activation analysis of geological samples is made. The changes introduced make the radiochemical separation simpler and more rapid. Both destructive and non destructive methods are tested by means of the analysis of the United States Geological Survey standard rock AGV-1, which has been analysed by many authors. The same procedure is then applied to some alcaline rocks taken from the apatite mine of Jacupiranga, in the State of Sao Paulo, Brazil. The knowledge of the trace element concentration in these rocks is important for geochemical studies. A detailed study of the possible interferences encountered in the neutron activation analysis of these rocks is made, considering the interferences due to major activities, and to the proximity of the several gamma ray energies of the radioisotopes produced. Finally, the comparative study between the two methods is presented, using statistical tests for the quantitative evalution of results. (Author) [pt

  19. STATISTICAL ANALYSIS OF ACOUSTIC WAVE PARAMETERS NEAR SOLAR ACTIVE REGIONS

    International Nuclear Information System (INIS)

    Rabello-Soares, M. Cristina; Bogart, Richard S.; Scherrer, Philip H.

    2016-01-01

    In order to quantify the influence of magnetic fields on acoustic mode parameters and flows in and around active regions, we analyze the differences in the parameters in magnetically quiet regions nearby an active region (which we call “nearby regions”), compared with those of quiet regions at the same disk locations for which there are no neighboring active regions. We also compare the mode parameters in active regions with those in comparably located quiet regions. Our analysis is based on ring-diagram analysis of all active regions observed by the Helioseismic and Magnetic Imager (HMI) during almost five years. We find that the frequency at which the mode amplitude changes from attenuation to amplification in the quiet nearby regions is around 4.2 mHz, in contrast to the active regions, for which it is about 5.1 mHz. This amplitude enhacement (the “acoustic halo effect”) is as large as that observed in the active regions, and has a very weak dependence on the wave propagation direction. The mode energy difference in nearby regions also changes from a deficit to an excess at around 4.2 mHz, but averages to zero over all modes. The frequency difference in nearby regions increases with increasing frequency until a point at which the frequency shifts turn over sharply, as in active regions. However, this turnover occurs around 4.9 mHz, which is significantly below the acoustic cutoff frequency. Inverting the horizontal flow parameters in the direction of the neigboring active regions, we find flows that are consistent with a model of the thermal energy flow being blocked directly below the active region.

  20. Reactor neutron activation for multielemental analysis

    International Nuclear Information System (INIS)

    Reddy, A.V.R.

    1999-01-01

    Neutron Activation Analysis using single comparator (K 0 NAA method) has been used for obtaining multielemental profiles in a variety of matrices related to environment. Gold was used as the comparator. Neutron flux was characterised by determining f, the epithermal to thermal neutron flux ratio and cc, the deviation from ideal shape of the neutron spectrum. The f and a were determined in different irradiation positions in APSARA reactor, PCF position in CIRUS reactor and tray rod position in Dhruva reactor using both cadmium cut off and multi isotope detector methods. High resolution gamma ray spectrometry was used for radioactive assay of the activation products. This technique is being used for multielement analysis in a variety of matrices like lake sediments, sea nodules and crusts, minerals, leaves, cereals, pulses, leaves, water and soil. Elemental profiles of the sediments corresponding to different depths from Nainital lake were determined and used to understand the history of natural absorption/desorption pattern of the previous 160 years. Ferromanganese crusts from different locations of Indian Ocean were analysed with a view to studying the distribution of some trace elements along with Fe and Mn. Variation of Mn/Fe ratio was used to identify the nature of the crusts as hydrogenous or hydrothermal. Fe-rich and Fe-depleted nodules from Indian Ocean were analysed to understand the REE patterns and it is proposed that REE-Th associated minerals could be the potential Th contributors to the sea water and thus reached ferromanganese nodules. Dolomites (unaltered and altered), two types of serpentines and intrusive rock dolerite from the asbestos mines of Cuddapah basin were analysed for major, minor and trace elements. The elemental concentrations are used for distinguishing and characterising these minerals. From our investigations, it was concluded that both dolomite and dolerite contribute elements in the serpentinisation process. Chemical neutron

  1. SWAN - Detection of explosives by means of fast neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gierlik, M., E-mail: m.gierlik@ncbj.gov.pl; Borsuk, S.; Guzik, Z.; Iwanowska, J.; Kaźmierczak, Ł.; Korolczuk, S.; Kozłowski, T.; Krakowski, T.; Marcinkowski, R.; Swiderski, L.; Szeptycka, M.; Szewiński, J.; Urban, A.

    2016-10-21

    In this work we report on SWAN, the experimental, portable device for explosives detection. The device was created as part of the EU Structural Funds Project “Accelerators & Detectors” (POIG.01.01.02-14-012/08-00), with the goal to increase beneficiary's expertise and competencies in the field of neutron activation analysis. Previous experiences and budged limitations lead toward a less advanced design based on fast neutron interactions and unsophisticated data analysis with the emphasis on the latest gamma detection and spectrometry solutions. The final device has been designed as a portable, fast neutron activation analyzer, with the software optimized for detection of carbon, nitrogen and oxygen. SWAN's performance in the role of explosives detector is elaborated in this paper. We demonstrate that the unique features offered by neutron activation analysis might not be impressive enough when confronted with practical demands and expectations of a generic homeland security customer.

  2. A Technique for Controlling Matric Suction on Filter Papers . GroWth ...

    African Journals Online (AJOL)

    'Abstract. Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers ...

  3. Activation analysis of ground water of Chandigarh

    International Nuclear Information System (INIS)

    Mittal, V.K.

    1997-01-01

    Ground water samples from Chandigarh were analysed for 22 trace elements using neutron activation analysis (NAA) technique. These samples were drawn from shallow aquifers using hand pumps. It was found that for most of the elements the concentrations were well within the ISI/WHO recommended values. However, samples collected from the industrial belt of the city showed higher concentrations of trace elements, particularly some toxic ones. (author). 6 refs., 1 tab

  4. Research reactor operations for neutron activation analysis

    International Nuclear Information System (INIS)

    Tv'ehlov, Yu.

    2002-01-01

    The IAEA Special Manual devoted to quality control during neutron activation analysis (NAA) on research and test reactors is discussed. Three parts of the publication involve presentation of common rules for performance of NAA, quantitative and qualitative analyses, statistic and systematic errors, safety regulations and radioactive waste management. Besides, the publication contains practical manual for the performance of NAA, and examples of different NAA regulating registration forms are presented [ru

  5. Elemental analysis of granite by instrumental neutron activation analysis (INAA) and X-ray fluorescence analysis (XRF)

    International Nuclear Information System (INIS)

    El-Taher, A.

    2012-01-01

    The instrumental neutron activation analysis technique (INAA) was used for qualitative and quantitative analysis of granite samples collected from four locations in the Aswan area in South Egypt. The samples were prepared together with their standards and simultaneously irradiated in a neutron flux of 7×10 11 n/cm 2 s in the TRIGA Mainz research reactor. Gamma-ray spectra from an hyper-pure germanium detector were analyzed. The present study provides the basic data of elemental concentrations of granite rocks. The following elements have been determined Na, Mg, K, Fe, Mn, Sc, Cr, Ti, Co, Zn, Ga, Rb, Zr, Nb, Sn, Ba, Cs, La, Ce, Nd, Sm, Eu, Yb, Lu, Hf, Ta, Th and U. The X-ray fluorescence (XRF) was used for comparison and to detect elements, which can be detected only by XRF such as F, S, Cl, Co, Cu, Mo, Ni, Pb, Se and V. The data presented here are our contribution to understanding the elemental composition of the granite rocks. Because there are no existing databases for the elemental analysis of granite, our results are a start to establishing a database for the Egyptian granite. It is hoped that the data presented here will be useful to those dealing with geochemistry, granite chemistry and related fields. - Highlights: ► Instrumental neutron activation analysis technique (INAA) was used for qualitative and quantitative analysis of granite. ► The samples were prepared together with their standards and simultaneously irradiated in a neutron flux of 7×10 11 n/cm 2 s in the TRIGA Mainz research reactor. ► Following elements have been determined Na, Mg, K, Fe, Mn, Sc, Cr, Ti, Co, Zn, Ga, Rb, Zr, Nb, Sn, Ba, Cs, La, Ce, Nd, Sm, Eu, Yb, Lu, Hf, Ta, Th and U.

  6. Determination of iodine 129 in vegetables using neutron activation analysis

    International Nuclear Information System (INIS)

    Quintana, Eduardo E.; Thyssen, Sandra M.; Bruno, Hector A.

    1999-01-01

    The developed methodology allows the determination of iodine 129 in vegetables, using neutron activation analysis. The chemical treatment removes the interferences present in these matrixes, as well as the bromine 82 originated in the activation process. The experimental method for the determination of iodine 129 by neutron activation analysis involves five steps: 1- digestion by alkaline fusion; 2- pre-irradiation purification of iodine 129 by distillation followed by solvent extraction, and adsorption on activated charcoal by distillation; 3- neutron irradiation; 4- post-irradiation purification of iodine 130 by distillation followed by solvent extraction; 5- gamma spectrometry. A chemical recovery of 95 % is obtained in the distillations, measured using iodine 131 as tracer. The whole process recovery is within 70 % and 85 %. The detection limit is 2 mBq/kg of sample, but several factors affect this value, such as type of vegetable, natural iodine concentration, irradiation time and neutron flux. The methodology developed is applied at environmental surveillance with safeguards proposes, in the detection of undeclared reprocessing of irradiated fuel. (authors)

  7. A Spatial Analysis of Tourism Activity in Romania

    Directory of Open Access Journals (Sweden)

    Daniela Luminita Constantin

    2018-02-01

    Full Text Available Location is a key concept in tourism sector analysis, given the dependence of this activity on the natural, built, cultural and social characteristics of a certain territory. As a result, the tourist zoning is an important instrument for delimiting tourist areas in accordance with multiple criteria, so as to lay the foundations for finding the most suitable solutions of turning to good account the resources in this field. The modern approaches proposed in this paper use a series of analytical tools that combine GIS and spatial agglomeration analysis based techniques. They can be also employed in order to examine and explain the differences between tourist zones (and sub-zones in terms of economic and social results and thus to suggest realistic ways to improve the efficiency and effectiveness of tourist activities in various geographical areas. In the described context this paper proposes an interdisciplinary perspective (spatial statistics and Geographical Information Systems for analysing the tourism activity in Romania, mainly aiming to identify the agglomerations of companies acting in this industry and assess their performance and contribution to the economic development of the corresponding regions. It also intends to contribute to a better understanding of the way in which tourism related business activities develop, in order to enhance appropriate support networks. Territorial and spatial statistics, as well as GIS based analyses are applied, using data about all companies acting in tourism industry in Romania provided by the National Authority for Tourism as well as data from the Environmental Systems Research Institute (ESRI.

  8. Directed Activities Related to Text: Text Analysis and Text Reconstruction.

    Science.gov (United States)

    Davies, Florence; Greene, Terry

    This paper describes Directed Activities Related to Text (DART), procedures that were developed and are used in the Reading for Learning Project at the University of Nottingham (England) to enhance learning from texts and that fall into two broad categories: (1) text analysis procedures, which require students to engage in some form of analysis of…

  9. Conceptualizing physical activity parenting practices using expert informed concept mapping analysis

    Directory of Open Access Journals (Sweden)

    Louise C. Mâsse

    2017-06-01

    Full Text Available Abstract Background Parents are widely recognized as playing a central role in the development of child behaviors such as physical activity. As there is little agreement as to the dimensions of physical activity-related parenting practices that should be measured or how they should be operationalized, this study engaged experts to develop an integrated conceptual framework for assessing parenting practices that influence multiple aspects of 5 to 12 year old children’s participation in physical activity. The ultimate goal of this study is to inform the development of an item bank (repository of calibrated items aimed at measuring physical activity parenting practices. Methods Twenty four experts from 6 countries (Australia, Canada, England, Scotland, the Netherlands, & United States (US sorted 77 physical activity parenting practice concepts identified from our previously published synthesis of the literature (74 measures and survey of Canadian and US parents. Concept Mapping software was used to conduct the multi-dimensional scaling (MDS analysis and a cluster analysis of the MDS solution of the Expert’s sorting which was qualitatively reviewed and commented on by the Experts. Results The conceptual framework includes 12 constructs which are presented using three main domains of parenting practices (neglect/control, autonomy support, and structure. The neglect/control domain includes two constructs: permissive and pressuring parenting practices. The autonomy supportive domain includes four constructs: encouragement, guided choice, involvement in child physical activities, and praises/rewards for their child’s physical activity. Finally, the structure domain includes six constructs: co-participation, expectations, facilitation, modeling, monitoring, and restricting physical activity for safety or academic concerns. Conclusion The concept mapping analysis provided a useful process to engage experts in re-conceptualizing physical activity

  10. Conceptualizing physical activity parenting practices using expert informed concept mapping analysis.

    Science.gov (United States)

    Mâsse, Louise C; O'Connor, Teresia M; Tu, Andrew W; Hughes, Sheryl O; Beauchamp, Mark R; Baranowski, Tom

    2017-06-14

    Parents are widely recognized as playing a central role in the development of child behaviors such as physical activity. As there is little agreement as to the dimensions of physical activity-related parenting practices that should be measured or how they should be operationalized, this study engaged experts to develop an integrated conceptual framework for assessing parenting practices that influence multiple aspects of 5 to 12 year old children's participation in physical activity. The ultimate goal of this study is to inform the development of an item bank (repository of calibrated items) aimed at measuring physical activity parenting practices. Twenty four experts from 6 countries (Australia, Canada, England, Scotland, the Netherlands, & United States (US)) sorted 77 physical activity parenting practice concepts identified from our previously published synthesis of the literature (74 measures) and survey of Canadian and US parents. Concept Mapping software was used to conduct the multi-dimensional scaling (MDS) analysis and a cluster analysis of the MDS solution of the Expert's sorting which was qualitatively reviewed and commented on by the Experts. The conceptual framework includes 12 constructs which are presented using three main domains of parenting practices (neglect/control, autonomy support, and structure). The neglect/control domain includes two constructs: permissive and pressuring parenting practices. The autonomy supportive domain includes four constructs: encouragement, guided choice, involvement in child physical activities, and praises/rewards for their child's physical activity. Finally, the structure domain includes six constructs: co-participation, expectations, facilitation, modeling, monitoring, and restricting physical activity for safety or academic concerns. The concept mapping analysis provided a useful process to engage experts in re-conceptualizing physical activity parenting practices and identified key constructs to include in

  11. Risk analysis within environmental impact assessment of proposed construction activity

    Energy Technology Data Exchange (ETDEWEB)

    Zeleňáková, Martina; Zvijáková, Lenka

    2017-01-15

    Environmental impact assessment is an important process, prior to approval of the investment plan, providing a detailed examination of the likely and foreseeable impacts of proposed construction activity on the environment. The objective of this paper is to develop a specific methodology for the analysis and evaluation of environmental impacts of selected constructions – flood protection structures using risk analysis methods. The application of methodology designed for the process of environmental impact assessment will develop assumptions for further improvements or more effective implementation and performance of this process. The main objective of the paper is to improve the implementation of the environmental impact assessment process. Through the use of risk analysis methods in environmental impact assessment process, the set objective has been achieved. - Highlights: This paper is informed by an effort to develop research with the aim of: • Improving existing qualitative and quantitative methods for assessing the impacts • A better understanding of relations between probabilities and consequences • Methodology for the EIA of flood protection constructions based on risk analysis • Creative approaches in the search for environmentally friendly proposed activities.

  12. Risk analysis within environmental impact assessment of proposed construction activity

    International Nuclear Information System (INIS)

    Zeleňáková, Martina; Zvijáková, Lenka

    2017-01-01

    Environmental impact assessment is an important process, prior to approval of the investment plan, providing a detailed examination of the likely and foreseeable impacts of proposed construction activity on the environment. The objective of this paper is to develop a specific methodology for the analysis and evaluation of environmental impacts of selected constructions – flood protection structures using risk analysis methods. The application of methodology designed for the process of environmental impact assessment will develop assumptions for further improvements or more effective implementation and performance of this process. The main objective of the paper is to improve the implementation of the environmental impact assessment process. Through the use of risk analysis methods in environmental impact assessment process, the set objective has been achieved. - Highlights: This paper is informed by an effort to develop research with the aim of: • Improving existing qualitative and quantitative methods for assessing the impacts • A better understanding of relations between probabilities and consequences • Methodology for the EIA of flood protection constructions based on risk analysis • Creative approaches in the search for environmentally friendly proposed activities.

  13. Large sample neutron activation analysis of a reference inhomogeneous sample

    International Nuclear Information System (INIS)

    Vasilopoulou, T.; Athens National Technical University, Athens; Tzika, F.; Stamatelatos, I.E.; Koster-Ammerlaan, M.J.J.

    2011-01-01

    A benchmark experiment was performed for Neutron Activation Analysis (NAA) of a large inhomogeneous sample. The reference sample was developed in-house and consisted of SiO 2 matrix and an Al-Zn alloy 'inhomogeneity' body. Monte Carlo simulations were employed to derive appropriate correction factors for neutron self-shielding during irradiation as well as self-attenuation of gamma rays and sample geometry during counting. The large sample neutron activation analysis (LSNAA) results were compared against reference values and the trueness of the technique was evaluated. An agreement within ±10% was observed between LSNAA and reference elemental mass values, for all matrix and inhomogeneity elements except Samarium, provided that the inhomogeneity body was fully simulated. However, in cases that the inhomogeneity was treated as not known, the results showed a reasonable agreement for most matrix elements, while large discrepancies were observed for the inhomogeneity elements. This study provided a quantification of the uncertainties associated with inhomogeneity in large sample analysis and contributed to the identification of the needs for future development of LSNAA facilities for analysis of inhomogeneous samples. (author)

  14. Neutron activation analysis of high purity substances

    International Nuclear Information System (INIS)

    Gil'bert, Eh.N.

    1987-01-01

    Peculiarities of neutron-activation analysis (NAA) of high purity substances are considered. Simultaneous determination of a wide series of elements, high sensitivity (the lower bound of determined contents 10 -9 -10 -10 %), high selectivity and accuracy (Sr=0.10-0.15, and may be decreased up to 0.001), possibility of analysis of the samples from several micrograms to hundreds of grams, simplicity of calibration may be thought NAA advantages. Questions of accounting of NAA systematic errors associated with the neutron flux screening by the analysed matrix and with production of radionuclides of determined elements from accompanying elements according to concurrent nuclear reactions, as well as accounting of errors due to self-absorption of recorded radiation by compact samples, are considered

  15. Uncertainty Assessments in Fast Neutron Activation Analysis

    International Nuclear Information System (INIS)

    W. D. James; R. Zeisler

    2000-01-01

    Fast neutron activation analysis (FNAA) carried out with the use of small accelerator-based neutron generators is routinely used for major/minor element determinations in industry, mineral and petroleum exploration, and to some extent in research. While the method shares many of the operational procedures and therefore errors inherent to conventional thermal neutron activation analysis, its unique implementation gives rise to additional specific concerns that can result in errors or increased uncertainties of measured quantities. The authors were involved in a recent effort to evaluate irreversible incorporation of oxygen into a standard reference material (SRM) by direct measurement of oxygen by FNAA. That project required determination of oxygen in bottles of the SRM stored in varying environmental conditions and a comparison of the results. We recognized the need to accurately describe the total uncertainty of the measurements to accurately characterize any differences in the resulting average concentrations. It is our intent here to discuss the breadth of potential parameters that have the potential to contribute to the random and nonrandom errors of the method and provide estimates of the magnitude of uncertainty introduced. In addition, we will discuss the steps taken in this recent FNAA project to control quality, assess the uncertainty of the measurements, and evaluate results based on the statistical reproducibility

  16. System analysis of vehicle active safety problem

    Science.gov (United States)

    Buznikov, S. E.

    2018-02-01

    The problem of the road transport safety affects the vital interests of the most of the population and is characterized by a global level of significance. The system analysis of problem of creation of competitive active vehicle safety systems is presented as an interrelated complex of tasks of multi-criterion optimization and dynamic stabilization of the state variables of a controlled object. Solving them requires generation of all possible variants of technical solutions within the software and hardware domains and synthesis of the control, which is close to optimum. For implementing the task of the system analysis the Zwicky “morphological box” method is used. Creation of comprehensive active safety systems involves solution of the problem of preventing typical collisions. For solving it, a structured set of collisions is introduced with its elements being generated also using the Zwicky “morphological box” method. The obstacle speed, the longitudinal acceleration of the controlled object and the unpredictable changes in its movement direction due to certain faults, the road surface condition and the control errors are taken as structure variables that characterize the conditions of collisions. The conditions for preventing typical collisions are presented as inequalities for physical variables that define the state vector of the object and its dynamic limits.

  17. Artifact suppression and analysis of brain activities with electroencephalography signals.

    Science.gov (United States)

    Rashed-Al-Mahfuz, Md; Islam, Md Rabiul; Hirose, Keikichi; Molla, Md Khademul Islam

    2013-06-05

    Brain-computer interface is a communication system that connects the brain with computer (or other devices) but is not dependent on the normal output of the brain (i.e., peripheral nerve and muscle). Electro-oculogram is a dominant artifact which has a significant negative influence on further analysis of real electroencephalography data. This paper presented a data adaptive technique for artifact suppression and brain wave extraction from electroencephalography signals to detect regional brain activities. Empirical mode decomposition based adaptive thresholding approach was employed here to suppress the electro-oculogram artifact. Fractional Gaussian noise was used to determine the threshold level derived from the analysis data without any training. The purified electroencephalography signal was composed of the brain waves also called rhythmic components which represent the brain activities. The rhythmic components were extracted from each electroencephalography channel using adaptive wiener filter with the original scale. The regional brain activities were mapped on the basis of the spatial distribution of rhythmic components, and the results showed that different regions of the brain are activated in response to different stimuli. This research analyzed the activities of a single rhythmic component, alpha with respect to different motor imaginations. The experimental results showed that the proposed method is very efficient in artifact suppression and identifying individual motor imagery based on the activities of alpha component.

  18. Inquiry-based Laboratory Activities on Drugs Analysis for High School Chemistry Learning

    Science.gov (United States)

    Rahmawati, I.; Sholichin, H.; Arifin, M.

    2017-09-01

    Laboratory activity is an important part of chemistry learning, but cookbook instructions is still commonly used. However, the activity with that way do not improve students thinking skill, especially students creativity. This study aims to improve high school students creativity through inquiry-based laboratory on drugs analysis activity. Acid-base titration is used to be method for drugs analysis involving a color changing indicator. The following tools were used to assess the activity achievement: creative thinking test on acid base titration, creative attitude and action observation sheets, questionnaire of inquiry-based lab activities, and interviews. The results showed that the inquiry-based laboratory activity improving students creative thinking, creative attitude and creative action. The students reacted positively to this teaching strategy as demonstrated by results from questionnaire responses and interviews. This result is expected to help teachers to overcome the shortcomings in other laboratory learning.

  19. Estimation of iodine in soils by neutron activation analysis

    International Nuclear Information System (INIS)

    Krishnamoorthy, K.R.; Iyer, R.K.

    1982-01-01

    This paper reports the determination of the iodine content of soils by neutron activation analysis. The irradiated sample is fused with alkali in presence of 131 I tracer. From the aqueous extract, iodine activity is extracted into carbon tetrachloride and stripped back to aqueous phase with a high selectivity for iodine. 131 I tracer is used to measure chemical yield. Iodine contents in the range 1 to 20 ppm. have been determined by this technique. (author)

  20. Progress report on neutron activation analysis at Dalat Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Tuan, Nguyen Ngoc [Nuclear Research Institute, Dalat (Viet Nam)

    2003-03-01

    Neutron Activation Analysis (NAA) is one of most powerful techniques for the simultaneous multi-elements analysis. This technique has been studied and applied to analyze major, minor and trace elements in Geological, Biological and Environmental samples at Dalat Nuclear Research Reactor. At the sixth Workshop, February 8-11, 1999, Yojakarta, Indonesia we had a report on Current Status of Neutron Activation Analysis using Dalat Nuclear Research Reactor. Another report on Neutron Activation Analysis at the Dalat Nuclear Research Reactor also was presented at the seventh Workshop in Taejon, Korea from November 20-24, 2000. So in this report, we would like to present the results obtained of the application of NAA at NRI for one year as follows: (1) Determination of the concentrations of noble, rare earth, uranium, thorium and other elements in Geological samples according to requirement of clients particularly the geologists, who want to find out the mineral resources. (2) The analysis of concentration of radionuclides and nutrient elements in foodstuffs to attend the program on Asian Reference Man. (3) The evaluation of the contents of trace elements in crude oil and basement rock samples to determine original source of the oil. (4) Determination of the elemental composition of airborne particle in the Ho Chi Minh City for studying air pollution. The analytical data of standard reference material, toxic elements and natural radionuclides in seawater are also presented. (author)

  1. Progress report on neutron activation analysis at Dalat Nuclear Research Reactor

    International Nuclear Information System (INIS)

    Tuan, Nguyen Ngoc

    2003-01-01

    Neutron Activation Analysis (NAA) is one of most powerful techniques for the simultaneous multi-elements analysis. This technique has been studied and applied to analyze major, minor and trace elements in Geological, Biological and Environmental samples at Dalat Nuclear Research Reactor. At the sixth Workshop, February 8-11, 1999, Yojakarta, Indonesia we had a report on Current Status of Neutron Activation Analysis using Dalat Nuclear Research Reactor. Another report on Neutron Activation Analysis at the Dalat Nuclear Research Reactor also was presented at the seventh Workshop in Taejon, Korea from November 20-24, 2000. So in this report, we would like to present the results obtained of the application of NAA at NRI for one year as follows: (1) Determination of the concentrations of noble, rare earth, uranium, thorium and other elements in Geological samples according to requirement of clients particularly the geologists, who want to find out the mineral resources. (2) The analysis of concentration of radionuclides and nutrient elements in foodstuffs to attend the program on Asian Reference Man. (3) The evaluation of the contents of trace elements in crude oil and basement rock samples to determine original source of the oil. (4) Determination of the elemental composition of airborne particle in the Ho Chi Minh City for studying air pollution. The analytical data of standard reference material, toxic elements and natural radionuclides in seawater are also presented. (author)

  2. The determination of some impurities in zirconium metal by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Pearton, D.C.G.; Watterson, J.J.

    1976-01-01

    This report describes the work done on the development of an instrumental neutron-activation method for the analysis of impurities in reactor-grade zirconium. Nine samples were analysed, and the results were compared with those obtained by other techniques. No statistically significant differences were observed for ten of the twelve elements that could possibly be determined by instrumental neutron-activation analysis. Cadmium cannot be determined at the 0,5 p.p.m. level, and there is doubt about the comparative values recorded for aluminium. The precision of the measurement by direct instrumental neutron-activation analysis ranges from 1,4 per cent for tungsten to 17 per cent for chromium [af

  3. Applications of short-lived activation products in neutron activation analysis of bio-environmental specimens

    International Nuclear Information System (INIS)

    1987-03-01

    This report discusses the advantages and disadvantages, special techniques, and actual and potential applications of neutron activation analysis (NAA) utilizing short-lived neutron-induced products, with special reference to the analysis of samples of biological and environmental origin. Attention is devoted mainly to products having half-lives in roughly the range of 10 milliseconds to 60 seconds, but with some discussion of the usefulness of even shorter-lived species, and ones with half-lives as long as a few minutes. Important aspects of the analytical methodology include sample preparation, irradiation/transfer systems, activity measurements, data processing and analytical quality assurance. It is concluded that several trace elements can be determined in bio-environmental samples (as well as in samples of industrial, geochemical and other origin). In particular, this method provides analytical possibilities for several elements (e.g. B, F, Li and V) that are difficult to determine in some matrices at trace levels by any other technique. These conclusions are illustrated in an annex by results of calculations in which the applicability of the techniques to the analysis of several biological and environmental reference materials is evaluated by means of an advance computer prediction program. The report concludes with an annotated bibliography of relevant publications (including abstracts, where available) taken from the INIS database. (author)

  4. A Markovian Entropy Measure for the Analysis of Calcium Activity Time Series.

    Science.gov (United States)

    Marken, John P; Halleran, Andrew D; Rahman, Atiqur; Odorizzi, Laura; LeFew, Michael C; Golino, Caroline A; Kemper, Peter; Saha, Margaret S

    2016-01-01

    Methods to analyze the dynamics of calcium activity often rely on visually distinguishable features in time series data such as spikes, waves, or oscillations. However, systems such as the developing nervous system display a complex, irregular type of calcium activity which makes the use of such methods less appropriate. Instead, for such systems there exists a class of methods (including information theoretic, power spectral, and fractal analysis approaches) which use more fundamental properties of the time series to analyze the observed calcium dynamics. We present a new analysis method in this class, the Markovian Entropy measure, which is an easily implementable calcium time series analysis method which represents the observed calcium activity as a realization of a Markov Process and describes its dynamics in terms of the level of predictability underlying the transitions between the states of the process. We applied our and other commonly used calcium analysis methods on a dataset from Xenopus laevis neural progenitors which displays irregular calcium activity and a dataset from murine synaptic neurons which displays activity time series that are well-described by visually-distinguishable features. We find that the Markovian Entropy measure is able to distinguish between biologically distinct populations in both datasets, and that it can separate biologically distinct populations to a greater extent than other methods in the dataset exhibiting irregular calcium activity. These results support the benefit of using the Markovian Entropy measure to analyze calcium dynamics, particularly for studies using time series data which do not exhibit easily distinguishable features.

  5. A Markovian Entropy Measure for the Analysis of Calcium Activity Time Series.

    Directory of Open Access Journals (Sweden)

    John P Marken

    Full Text Available Methods to analyze the dynamics of calcium activity often rely on visually distinguishable features in time series data such as spikes, waves, or oscillations. However, systems such as the developing nervous system display a complex, irregular type of calcium activity which makes the use of such methods less appropriate. Instead, for such systems there exists a class of methods (including information theoretic, power spectral, and fractal analysis approaches which use more fundamental properties of the time series to analyze the observed calcium dynamics. We present a new analysis method in this class, the Markovian Entropy measure, which is an easily implementable calcium time series analysis method which represents the observed calcium activity as a realization of a Markov Process and describes its dynamics in terms of the level of predictability underlying the transitions between the states of the process. We applied our and other commonly used calcium analysis methods on a dataset from Xenopus laevis neural progenitors which displays irregular calcium activity and a dataset from murine synaptic neurons which displays activity time series that are well-described by visually-distinguishable features. We find that the Markovian Entropy measure is able to distinguish between biologically distinct populations in both datasets, and that it can separate biologically distinct populations to a greater extent than other methods in the dataset exhibiting irregular calcium activity. These results support the benefit of using the Markovian Entropy measure to analyze calcium dynamics, particularly for studies using time series data which do not exhibit easily distinguishable features.

  6. Applied research of environmental monitoring using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Young Sam; Moon, Jong Hwa; Chung, Young Ju

    1997-08-01

    This technical report is written as a guide book for applied research of environmental monitoring using Instrumental Neutron Activation Analysis. The contents are as followings; sampling and sample preparation as a airborne particulate matter, analytical methodologies, data evaluation and interpretation, basic statistical methods of data analysis applied in environmental pollution studies. (author). 23 refs., 7 tabs., 9 figs.

  7. Procedures for multielement analysis using high-flux fast-neutron activation

    International Nuclear Information System (INIS)

    Williams, R.E.; Hopke, P.K.; Meyer, R.A.

    1981-06-01

    Improvements have been made in the rabbit system used for multi-element fast-neutron activation analysis at the Lawrence Livermore National Laboratory Rotating Target Neutron Source, RTNS-I. Procedures have been developed for the analysis of 20 to 25 elements in samples with an inorganic matrix and 10 to 15 elements in biological samples, without the need for prohibitively expensive, long irradiations. Results are presented for the analysis of fly ash, orchard leaves, and bovine liver

  8. Obsidian sources characterized by neutron-activation analysis.

    Science.gov (United States)

    Gordus, A A; Wright, G A; Griffin, J B

    1968-07-26

    Concentrations of elements such as manganese, scandium, lanthanum, rubidium, samarium, barium, and zirconium in obsidian samples from different flows show ranges of 1000 percent or more, whereas the variation in element content in obsidian samples from a single flow appears to be less than 40 percent. Neutron-activation analysis of these elements, as well as of sodium and iron, provides a means of identifying the geologic source of an archeological artifact of obsidian.

  9. Reactor neutron activation analysis of industrial materials

    International Nuclear Information System (INIS)

    Niese, S.

    1983-01-01

    The specific application of neutron activation analysis (n.a.a.) for industrial materials is demonstrated by the determination of impurities in BeO, Al, Si, Cu, Ge, GaP, GaAs, steel, and irradiated uranium. A group scheme gives an orientation about the possibilities of n.a.a. The use of different standards, methods for the measurement of low radioactivities and errors caused by recoil reaction and radiation stimulated diffusion are discussed. (author)

  10. Neutron activation analysis with k0-standardisation : general formalism and procedure

    International Nuclear Information System (INIS)

    Pomme, S.; Hardeman, F.; Robouch, P.; Etxebarria, N.; Arana, G.

    1997-09-01

    Instrumental neutron activation analysis (INAA) with k 0 -standardisation is a powerful tool for multi-element analysis at a broad range of trace element concentrations. An overview is given of the basic principles, fundamental equations, and general procedure of this method. Different aspects of the description of the neutron activation reaction rate are discussed, applying the Hogdahl convention. A general activation-decay formula is derived and its application to INAA is demonstrated. Relevant k 0 -definitions for different activation decay schemes are summarised and upgraded to cases of extremely high fluxes. The main standardisation techniques for INAA are discussed, emphasizing the k 0 -standardisation. Some general aspects of the basic equipment and its calibration are discussed, such as the characterisation of the neutron field and the tuning of the spectrometry part. A method for the prediction and optimisation of the analytical performance of INAA is presented

  11. Molecular activation analysis for organo-halogen contaminants in yogurt

    International Nuclear Information System (INIS)

    Zhang Hong; Chai Zhifang

    2004-01-01

    The concentrations of total halogen (TX), extractable organo-halogen (EOX), extractable persistent organo-halogen (EPOX), organo-chlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in 18 different yogurt specimens of 14 brands from Beijing, Tianjin, Shanghai, Guangzhou and Shijiazhuang were determined by epithermal neutron activation analysis (ENAA), molecular activation analysis (MAA) and GC-Mass Spectrometry (GC-MS), respectively. The results indicated that the halogen in yogurt mainly existed as inorganic species and non-extractable organo-halogen compounds. About 1/3 to 1/4 of EOX was EPOX. Further, EOCl and EPOCl were the main organo-halogen species in yogurt. The average concentration of the unknown organo-chlorine was 96% of the EPOCl. HCHs and DDTs were still the main contaminants of OCPs in the yogurt of interest. Also, PCB202, PCB103 and PCB208 were the main contaminants of PCBs. (authors)

  12. Charged particle activation analysis of phosphorus in biological materials

    International Nuclear Information System (INIS)

    Masumoto, K.; Yagi, M.

    1983-01-01

    Charged particle activation analysis of phosphorus in biological materials using the 31 P(α,n) sup(34m)Cl reaction has been studied. Since sup(34m)Cl is also produced by the 32 S(α,pn) and the 35 Cl(α,α'n) reactions, the thick-target yield curves on phosphorus, sulfur and chlorine were determined in order to choose the optimum irradiation conditions. As a result, it was found that the activation analysis for phosphorus without interferences from sulfur and chlorine is possible by bombarding with less than 17 MeV alphas. The applicability of this method to biological samples was then examined by irradiating several standard reference materials. It was confirmed that phosphorus can readily be determined at the detection limit of 1μg free from interferences due to the matrix elements. (author)

  13. Automated absolute activation analysis with californium-252 sources

    International Nuclear Information System (INIS)

    MacMurdo, K.W.; Bowman, W.W.

    1978-09-01

    A 100-mg 252 Cf neutron activation analysis facility is used routinely at the Savannah River Laboratory for multielement analysis of many solid and liquid samples. An absolute analysis technique converts counting data directly to elemental concentration without the use of classical comparative standards and flux monitors. With the totally automated pneumatic sample transfer system, cyclic irradiation-decay-count regimes can be pre-selected for up to 40 samples, and samples can be analyzed with the facility unattended. An automatic data control system starts and stops a high-resolution gamma-ray spectrometer and/or a delayed-neutron detector; the system also stores data and controls output modes. Gamma ray data are reduced by three main programs in the IBM 360/195 computer: the 4096-channel spectrum and pertinent experimental timing, counting, and sample data are stored on magnetic tape; the spectrum is then reduced to a list of significant photopeak energies, integrated areas, and their associated statistical errors; and the third program assigns gamma ray photopeaks to the appropriate neutron activation product(s) by comparing photopeak energies to tabulated gamma ray energies. Photopeak areas are then converted to elemental concentration by using experimental timing and sample data, calculated elemental neutron capture rates, absolute detector efficiencies, and absolute spectroscopic decay data. Calculational procedures have been developed so that fissile material can be analyzed by cyclic neutron activation and delayed-neutron counting procedures. These calculations are based on a 6 half-life group model of delayed neutron emission; calculations include corrections for delayed neutron interference from 17 O. Detection sensitivities of 239 Pu were demonstrated with 15-g samples at a throughput of up to 140 per day. Over 40 elements can be detected at the sub-ppM level

  14. Applicability of neutron activation analysis to geological samples

    Energy Technology Data Exchange (ETDEWEB)

    Ebihara, Mitsuru [Tokyo Metropolitan Univ., Graduate School of Science, Tokyo (Japan)

    2003-03-01

    The applicability of neutron activation analysis (NAA) to geological samples in space is discussed by referring to future space mission programs, by which the extraterrestrial samples are to be delivered to the earth for scientific inspections. It is concluded that both destructive and non-destructive NAA are highly effective in analyzing these samples. (author)

  15. Applicability of neutron activation analysis to geological samples

    International Nuclear Information System (INIS)

    Ebihara, Mitsuru

    2003-01-01

    The applicability of neutron activation analysis (NAA) to geological samples in space is discussed by referring to future space mission programs, by which the extraterrestrial samples are to be delivered to the earth for scientific inspections. It is concluded that both destructive and non-destructive NAA are highly effective in analyzing these samples. (author)

  16. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Bayat, I.; Fischer, E.

    1976-05-01

    For the determination of trace elements in foodstuffs with the aid of neutron activation analysis the separation of volatile radionuclides after digestion of the sample is of special interest for radiochemical processing. A distillation procedure was developed to give reproducable results, however optimal conditions were not found for all volatile radionuclides studied. The required selective separation of Br-82 from the distillate was best achieved by the application of an ion-exchange column-chromatography technique. The computer programs for the evaluation of complex gamma spectra have been developed further. The automatic peak search and peak area determination is based on a computer program using the correlation technique and carried out with a mini-computer coupled with a multi-channel gamma spectrometer. The results, which are presented in 3 earlier reports relating to this research program, reveal the advantages and disadvantages of the individual steps of the radiochemical separation scheme. Before neutron activation analysis can be introduced on a routine basis, some aspects of the radiochemical process remain to be tested; these studies will be published in a fourth and final report. (orig.) [de

  17. Leisure-time physical activity and sciatica: A systematic review and meta-analysis.

    Science.gov (United States)

    Shiri, R; Falah-Hassani, K; Viikari-Juntura, E; Coggon, D

    2016-11-01

    The role of leisure-time physical activity in sciatica is uncertain. This study aimed to assess the association of leisure-time physical activity with lumbar radicular pain and sciatica. Literature searches were conducted in PubMed, Embase, Web of Science, Scopus, Google Scholar and ResearchGate databases from 1964 through August 2015. A random-effects meta-analysis was performed, and heterogeneity and small-study bias were assessed. Ten cohort (N = 82,024 participants), four case-control (N = 9350) and four cross-sectional (N = 10,046) studies qualified for meta-analysis. In comparison with no regular physical activity, high level of physical activity (≥4 times/week) was inversely associated with new onset of lumbar radicular pain or sciatica in a meta-analysis of prospective cohort studies [risk ratio (RR) = 0.88, 95% CI 0.78-0.99, I 2  = 0%, 7 studies, N = 78,065]. The association for moderate level of physical activity (1-3 times/week) was weaker (RR = 0.93, CI 0.82-1.05, I 2  = 0%, 6 studies, N = 69,049), and there was no association with physical activity for at least once/week (RR = 0.99, CI 0.86-1.13, 9 studies, N = 73,008). In contrast, a meta-analysis of cross-sectional studies showed a higher prevalence of lumbar radicular pain or sciatica in participants who exercised at least once/week [prevalence ratio (PR) = 1.29, CI 1.09-1.53, I 2  = 0%, 4 studies, N = 10,046], or 1-3 times/week (PR = 1.34, CI 1.02-1.77, I 2  = 0%, N = 7631) than among inactive participants. There was no evidence of small-study bias. This meta-analysis suggests that moderate to high level of leisure physical activity may have a moderate protective effect against development of lumbar radicular pain. However, a large reduction in risk (>30%) seems unlikely. Leisure-time physical activity may reduce the risk of developing lumbar radicular pain. © 2016 European Pain Federation - EFIC®.

  18. Support system for Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Sasajima, Fumio; Ohtomo, Akitoshi; Sakurai, Fumio; Onizawa, Koji

    1999-01-01

    In the research reactor of JAERI, the Neutron Activation Analysis (NAA) has been utilized as a major part of an irradiation usage. To utilize NAA, research participants are always required to learn necessary technique. Therefore, we started to examine a support system that will enable to carry out INAA easily even by beginners. The system is composed of irradiation device, gamma-ray spectrometer and data analyzing instruments. The element concentration is calculated by using KAYZERO/SOLCOI software with the K 0 standardization method. In this paper, we review on a construction of this INAA support system in JRR-3M of JAERI. (author)

  19. Opportunities for innovation in neutron activation analysis

    International Nuclear Information System (INIS)

    Peter Bode

    2012-01-01

    Neutron activation laboratories worldwide are at a turning point at which new staff has to be found for the retiring pioneers from the 1960s-1970s. A scientific career in a well-understood technique, often characterized as 'mature' may only be attractive to young scientists if still challenges for further improvement and inspiring new applications can be offered. The strengths and weaknesses of neutron activation analysis (NAA) are revisited to identify opportunities for innovation. Position-sensitive detection of elements in large samples, Monte Carlo calculations replacing the use of standards, use of scintillator detectors and new deconvolution techniques for increasing the sensitivity are examples of challenging new roads in NAA. Material science provides challenges for the application of NAA in both bulk samples, ultrathin layers and ultrapure materials. (author)

  20. Biofac, a microbiological multimedia tool to perform the analysis of activated sludge

    International Nuclear Information System (INIS)

    Ferrer Torregrosa, C.; Llopis Nicolau, A.; Claramonte Santarrufina, J.; Alonso Hernandez, S.

    2009-01-01

    The composition and structure of the macrobiotic that is part of the active sludge, its temporal evolution, and the analysis of the macroscopic and microscopic characteristics of it are a source of information of great help in making decisions for plant operators. Lack of training and access to specific information linked to the missing standardization of analysis processes hinder the implementation and interpretation of them. Using a multimedia tool in DVD, Facsa has developed the Biofac, an application in which it is documented and illustrated the most relevant aspects that allow the user to perform the analysis of activated sludge. (Author)

  1. Data reduction for a high-throughput neutron activation analysis system

    International Nuclear Information System (INIS)

    Bowman, W.W.

    1979-01-01

    To analyze samples collected as part of a geochemical survey for the National Uranium Resource Evaluation program, Savannah River Laboratory has installed a high-throughput neutron activation analysis system. As part of that system, computer programs have been developed to reduce raw data to elemental concentrations in two steps. Program RAGS reduces gamma-ray spectra to lists of photopeak energies, peak areas, and statistical errors. Program RICHES determines the elemental concentrations from photopeak and delayed-neutron data, detector efficiencies, analysis parameters (neutron flux and activation, decay, and counting times), and spectrometric and cross-section data from libraries. Both programs have been streamlined for on-line operation with a minicomputer, each requiring approx. 64 kbytes of core. 3 tables

  2. Records in ultra low radioactivity measurements with neutron activation analysis

    International Nuclear Information System (INIS)

    Hentig, R. von; Goldbrunner, T.; Angloher, G.; Feilitzsch, F. von

    1999-01-01

    Neutron Activation Analysis has emerged to be an analytical method sensitive enough to detect fg/g traces of unstable primordial nuclides in complex matrices. Especially low count rate experiments in the field of solar neutrino physics and dark matter search can profit from the detection capabilities of this method which had been unattained so far. This gain in sensitivity has been achieved by combining neutron activation, radiochemical separation methods, and efficient low level counting systems at the new underground laboratory of the accelerator laboratory in Garching. Recent improvements which have been made in the purification and analysis of the liquid scintillator, as foreseen for the solar neutrino experiment BOREXINO, are being presented as an example in this paper

  3. Cross-interval histogram analysis of neuronal activity on multi-electrode arrays

    NARCIS (Netherlands)

    Castellone, P.; Rutten, Wim; Marani, Enrico

    2003-01-01

    Cross-neuron-interval histogram (CNIH) analysis has been performed in order to study correlated activity and connectivity between pairs of neurons in a spontaneously active developing cultured network of rat cortical cells. Thirty-eight histograms could be analyzed using two parameters, one for the

  4. Uncertainty Estimation of Neutron Activation Analysis in Zinc Elemental Determination in Food Samples

    International Nuclear Information System (INIS)

    Endah Damastuti; Muhayatun; Diah Dwiana L

    2009-01-01

    Beside to complished the requirements of international standard of ISO/IEC 17025:2005, uncertainty estimation should be done to increase quality and confidence of analysis results and also to establish traceability of the analysis results to SI unit. Neutron activation analysis is a major technique used by Radiometry technique analysis laboratory and is included as scope of accreditation under ISO/IEC 17025:2005, therefore uncertainty estimation of neutron activation analysis is needed to be carried out. Sample and standard preparation as well as, irradiation and measurement using gamma spectrometry were the main activities which could give contribution to uncertainty. The components of uncertainty sources were specifically explained. The result of expanded uncertainty was 4,0 mg/kg with level of confidence 95% (coverage factor=2) and Zn concentration was 25,1 mg/kg. Counting statistic of cuplikan and standard were the major contribution of combined uncertainty. The uncertainty estimation was expected to increase the quality of the analysis results and could be applied further to other kind of samples. (author)

  5. High content analysis of phagocytic activity and cell morphology with PuntoMorph

    DEFF Research Database (Denmark)

    Al-Ali, Hassan; Gao, Han; Dalby-Hansen, Camilla

    2017-01-01

    methods for quantifying phagocytic activity in multiple dimensions including speed, accuracy, and resolution. Conclusions We provide a framework to facilitate the development of high content assays suitable for drug screening. For convenience, we implemented our algorithm in a standalone software package...... with image-based quantification of phagocytic activity. New method We present a robust algorithm and cell-based assay system for high content analysis of phagocytic activity. The method utilizes fluorescently labeled beads as a phagocytic substrate with defined physical properties. The algorithm employs...... content screening. Results We tested our assay system using microglial cultures. Our results recapitulated previous findings on the effects of microglial stimulation on cell morphology and phagocytic activity. Moreover, our cell-level analysis revealed that the two phenotypes associated with microglial...

  6. Empirical Analysis of Intonation Activities in EFL Student’s Books

    Directory of Open Access Journals (Sweden)

    Dušan Nikolić

    2018-05-01

    Full Text Available Intonation instruction has repeatedly proved a challenge for EFL teachers, who avoid getting involved in intonation teaching more than their EFL textbooks demand from them. Since a great number of teachers rely on EFL textbooks when implementing intonation practice, the intonation activities in EFL materials are often central to their classroom. Even though the research on intonation instruction has been well-documented, few papers have explored intonation activities in EFL materials. The present study thus provides an empirical analysis of intonation activities in five EFL student’s books series by exploring the overall coverage of intonation activities across the series and the quality of these activities. The results reveal that intonation activities are underrepresented in the EFL student’s books, and that discourse intonation deserves more attention in the activities. Considerations for EFL teachers and publishers are also discussed.

  7. Activation Analysis in Forensic Science. Survey Paper

    Energy Technology Data Exchange (ETDEWEB)

    Jervis, R. E. [University of Toronto, Toronto (Canada)

    1967-10-15

    Recently the unique features of the activation analysis method have been utilized to advantage to meet some specialized needs in the scientific investigation of crime. A review of the principal forensic activation analysis applications to biological materials to date indicates that they may be roughly classified as: (i) the detection and determination of residues of toxic materials in foodstuffs, human tissues, sera and excreta; (ii) the 'individualization' of hair, fibres, narcotics and drugs; and (iii) investigation of the transference of ballistic material to bone, cloth or paper. Analyses of these materials in some actual forensic investigations have been perfected to the point of acceptance in the law courts of several countries. Additional and broader areas of application are under development in a number of nuclear and forensic laboratories. (i) The determination of sub microgram quantities of phosphorus compounds, arsenic, mercury, selenium and thallium in specimens from post-mortem examinations and from living persons showing symptoms of toxicity has revealed certain ingestion of abnormal amount of toxic substances by comparison with similar specimens from healthy persons. In some cases, with tissues such as hair and nails, the time scale of the ingestion of arsenic or mercury has been revealed through the distribution of the deposited element with distance from the growing end or edge. (ii) A series of feasibility studies on the possibility of distinguishing similar materials through their characteristic trace-element patterns have resulted from observations of the wide range or variation in trace impurity content in specimens which come from different individuals or different natural sources. For example, extensive activation analyses for more than twenty elements in human head hair from many people have been carried out and a statistical analysis of the results indicate that activation hair comparisons in forensic investigations may be quite definitive

  8. Application of instrumental neutron activation analysis and X-ray fluorescence analysis in art pieces investigation

    International Nuclear Information System (INIS)

    Panczyk, E.; Kierzek, J.; Walis, L.; Ligeza, M.

    1996-01-01

    The application of instrumental neutron activation analysis have been shown for the trace element identification in dyes of old painting and other art objects. The recognition of their composition is a important measure for attribution. Also the X-ray fluorescence analysis has been frequently used for examination of art objects. The age determination of the old chinese porcelain is a good example described in the paper. 20 refs, 4 figs

  9. Conversion Matrix Analysis of GaAs HEMT Active Gilbert Cell Mixers

    DEFF Research Database (Denmark)

    Jiang, Chenhui; Johansen, Tom Keinicke; Krozer, Viktor

    2006-01-01

    In this paper, the nonlinear model of the GaAs HEMT active Gilbert cell mixer is investigated. Based on the model, the conversion gain expression of active Gilbert cell mixers is derived theoretically by using conversion matrix analysis method. The expression is verified by harmonic balance simul...

  10. Antioxidant activity and FT-IR analysis of Datura innoxia and Datura ...

    African Journals Online (AJOL)

    Materials and Methods: Determination of total phenolic content and total flavonoid content and antioxidant activity in terms of total antioxidant assay, ABTS assay, DPPH assay and in-vitro lipid peroxidation inhibiting activity were determined along with the FT-IR (Fourier transform infrared spectroscopy) analysis of the ...

  11. Application of short-time activation analysis in the sciences

    International Nuclear Information System (INIS)

    Grass, F.

    1991-01-01

    Short-time activation analysis has proved to be a valuable tool in nearly all fields of science. To take full advantage of this technique, it is favorable to use a fast transfer system and a high resolution high rate gamma-spectroscopy system for short lived gamma-emitters and a Cherenkov detector for the determination of hard beta-emitters. It is then possible to utilize sub-minute nuclides Li-8 (740 ms), B-12 (20 ms), F-20 (11.1 s), Y-89m (16 s), and Pb-207m (800 ms) for the determination of these elements. Besides these sub-minute nuclides which constitute the only possibility for neutron activation analysis of these elements there are a number of other elements which form longer lived nuclides on short irradiation. The analysis of the halogenides F, Cl, Br, I in waste water of a sewage incineration plant can be achieved with a single 20 s irradiation and two consecutive measurement of 20 and 600 s using Cl-38m, F-20, Br-79m as well as the longer lived Cl-38, Br-80, I-128

  12. The multielement potential of fast neutron cyclic activation analysis

    International Nuclear Information System (INIS)

    Nonie, S.E.; Randle, K.

    1994-01-01

    Cyclic neutron activation analysis (CNAA) has, in recent years been developed as a useful analytical tool for the assay of short-lived isotopes in single element situations. The work described in this paper investigates the potential of the technique for composite samples having a wide range of elements that produce short-lived and long-lived isotopes on neutron irradiation. Accelerator-derived neutrons with average energies of 3 MeV, 6 MeV and 14 MeV were employed in what has been dubbed 'Fast Neutron Cyclic Neutron Activation Analysis' (FNCAA). The approach to multi-element analysis entailed: determination of cycle parameters in single element samples via the reactions 27 Al(n,p) 27 Mg(9.6 min,E γ =840keV), and 137 Ba(n,n 'γ137m Ba(2.3 min,E γ 137m Ba(2.3 min,E γ =662 keV), a test of the method on a composite rock sample, determination of analytical sensitivities using both powdered kale and rock standards and a comparison of analytical results with other techniques. The results obtained in all these measurements are presented and discussed. (author) 10 refs.; 3 figs.; 5 tabs

  13. Development of Distinction Method of Production Area of Ginsengs by Using a Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin; Chung, Yong Sam; Sun, Gwang Min; Lee, Yu Na; Yoo, Sang Ho [KAERI, Daejeon (Korea, Republic of)

    2010-05-15

    Distinction of production area of Korean ginsengs has been tried by using neutron activation techniques such as an instrumental neutron activation analysis (INAA) and a prompt gamma activation analysis (PGAA). A distribution of elements has varied according to the part of plant clue to the difference of enrichment effect and influence from a soil where the plants have been grown. So correlation study between plants and soil has been an Issue. In this study, the distribution of trace elements within a Korean ginseng was investigated by using an instrumental neutron activation analysis

  14. Accuracy and precision in activation analysis: counting

    International Nuclear Information System (INIS)

    Becker, D.A.

    1974-01-01

    Accuracy and precision in activation analysis was investigated with regard to counting of induced radioactivity. The various parameters discussed include configuration, positioning, density, homogeneity, intensity, radioisotopic purity, peak integration, and nuclear constants. Experimental results are presented for many of these parameters. The results obtained indicate that counting errors often contribute significantly to the inaccuracy and imprecision of analyses. The magnitude of these errors range from less than 1 percent to 10 percent or more in many cases

  15. Investigations on the comparator technique used in epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Bereznai, T.; Bodizs, D.; Keoemley, G.

    1977-01-01

    The possible extension of the comparator technique of reactor neutron activation analysis into the field of epithermal neutron activation has been investigated. Ruthenium was used for multi-isotopic comparator. Experiments show that conversion of the so-called reference k-factors - determined by irradiation with reactor neutrons - into ksup(epi)-factors usable at activation under cadmium filter, can be evaluated with fair accuracy. Sources and extent of errors and their contribution to the final error of analysis are discussed. For equal irradiation and counting times advantage of ENAA for several elements is obvious: the much lower background activity permitted the sample to be measured closer to the detector, under better geometry conditions, consequently, permitting several elements to be determined quantitatively. The number of elements determined and the sensitivity of the method are much dependent on the experimental conditions, especially on the composition of the sample, on the PHIsub(e) value, the irradiation time and the efficiency of the Ge(Li) detector. (T.G.)

  16. Probing Trace-elements in Bitumen by Neutron Activation Analysis

    NARCIS (Netherlands)

    Nahar, S.N.; Schmets, A.J.M.; Scarpas, Athanasios

    Trace elements and their concentrations play an important role in both chemical and physical properties of bitumen. Instrumental Neutron Activation Analysis (INAA) has been applied to determine the concentration of trace elements in bitumen. This method requires irradiation of the material with

  17. Improved Gasifier Availability with Bed Material and Additives

    Energy Technology Data Exchange (ETDEWEB)

    Grootjes, A.J.; Van der Meijden, C.M.; Visser, H.J.M.; Van der Drift, A. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2013-07-15

    In order to valorize several feedstock, gasification is one of the technologies developed over the past decades. ECN developed the MILENA gasifier. In order for MILENA to become a commercial success, the gasifier needs to be feedstock flexible, robust and economically sound, operating with high availability. One of the characteristics of MILENA is high efficiency but with a higher tar content, compared to some other Dual Fluidized Bed (DFB) gasifiers. In order to reduce the issues that are associated with high tar levels in the product gas, the effect of a number of primary measures was studied. This paper presents results obtained in the last two years, focused on improving the gasifier availability by conducting experiments in a 25 kWth lab scale MILENA gasifier. Amongst others, gas composition, tar content and calorific value of the product gas were compared. Scanning Electron Microscope analysis was used to investigate bed material changes. Results show that Austrian olivine can be activated by Fuel B as well as by Additive A and B. The water-gas shift reaction is enhanced and the tar content is reduced significantly, especially the heavy tars that dominate the tar dew point. Activated olivine has a calcium-rich layer. The results show that with MILENA, we are able to lower and control the tar dew point, which will possibly increase the availability of a MILENA gasifier.

  18. Study of gamma ray analysis software's. Application to activation analysis of geological samples

    International Nuclear Information System (INIS)

    Silva, Luiz Roberto Nogueira da

    1998-01-01

    A comparative evaluation of the gamma-ray analysis software VISPECT, in relation to two commercial gamma-ray analysis software packages, OMNIGAM (EG and G Ortec) and SAMPO 90 (Canberra) was performed. For this evaluation, artificial gamma ray spectra were created, presenting peaks of different intensities and located at four different regions of the spectrum. Multiplet peaks with equal and different intensities, but with different channel separations, were also created. The results obtained showed a good performance of VISPECT in detecting and analysing single and multiplet peaks of different intensities in the gamma-ray spectrum. Neutron activation analysis of the geological reference material GS-N (IWG-GIT) and of the granite G-94, used in a Proficiency Testing Trial of Analytical Geochemistry Laboratories, was also performed , in order to evaluate the VISEPCT software in the analysis of real samples. The results obtained by using VISPECT were as good or better than the ones obtained using the other programs. (author)

  19. Neutron activation analysis of the MIBI, MAG-3 and sodium fitate active principles

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Sayaz, G.; Moreno Bermudez, J.; Ribeiro Guevara, S.; Molina Insfran, J.

    1996-01-01

    Neutron activation analysis (NAA) both instrumental (INAA) and radiochemical (RNAA) are extensively applied for determination of minor and trace elements in samples of quite different origin and composition. Particularly, the application of INAA is well recognized for analysis of microquantitis of heavy metals as well as toxic elements in biological samples. In this work the possibility of the determination of MIBI, MAG-3 and sodium fitate elemental composition by INAA was investigated Analytical information about the concentration and/or detection limits of some toxic elements (Hg, Cd, As, Se, Sb) and other trace elements of interest (Fe, Cr, Co, Zn, Br) was obtained. The samples were irradiated in the CAb Ra-6 nuclear research reactor

  20. Rare earths analysis of rock samples by instrumental neutron activation analysis, internal standard method

    International Nuclear Information System (INIS)

    Silachyov, I.

    2016-01-01

    The application of instrumental neutron activation analysis for the determination of long-lived rare earth elements (REE) in rock samples is considered in this work. Two different methods are statistically compared: the well established external standard method carried out using standard reference materials, and the internal standard method (ISM), using Fe, determined through X-ray fluorescence analysis, as an element-comparator. The ISM proved to be the more precise method for a wide range of REE contents and can be recommended for routine practice. (author)

  1. Physical activity and body image among men and boys: A meta-analysis.

    Science.gov (United States)

    Bassett-Gunter, Rebecca; McEwan, Desmond; Kamarhie, Aria

    2017-09-01

    Three meta-analytic reviews have concluded that physical activity is positively related to body image. Historically, research regarding physical activity and body image has been disproportionately focused on female samples. For example, the most recent meta-analysis (2009) extracted 56 effect sizes for women and only 12 for men. The current paper provides an update to the literature regarding the relationship between physical activity and body image among men and boys across 84 individual effect sizes. The analysis also provides insight regarding moderator variables including participant age, and physical activity type and intensity. Overall, physical activity was positively related to body image among men and boys with various moderator variables warranting further investigation. Pragmatic implications are discussed as well as the limitations within existing research and need for additional research to further understand moderator and mediator variables. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Multielement analysis of Nigerian chewing sticks by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Asubiojo, O.I.; Guinn, V.P.

    1982-01-01

    In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as 'chewing sticks'. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis. (author)

  3. Director, Operational Test and Evaluation FY 2006 Annual Report

    Science.gov (United States)

    2006-12-01

    that no other Servces be authorized to field Block 1 without successful IOT&E or specal authorzaton to meet wart me necesstes. The Marne...built in Germany and shipped to Columbus for final assembly. The Mississippi plant will undergo a major expansion to accommodate the LUH program...The plant wll begn wth partal assembly, followed by full assembly, and finally the subsequent U.S. manufacture of major subsystems. The Army

  4. Reference: 495 [Arabidopsis Phenome Database[Archive

    Lifescience Database Archive (English)

    Full Text Available . Emission of methanethiol from Arabidopsis plants supplied with 10 mM L-methionine was undetectable (cation in an alternat...>homocysteine-->cystathionine-->cysteine) in which methanethiol is an intermediate. Functional characterizat...wth on L-methionine as sole nitrogen source and conferred a high rate of methanethiol emission. The purified...mol min(-1) g(-1) FW), suggesting that AtMGL is not an important source of volatile methanethiol. Knocking o

  5. Minutes of the Explosives Safety Seminar (16th), Held at the Diplomat Hotel, Hollywood, Florida on 24-26 September 1974. Volume I

    Science.gov (United States)

    1974-09-26

    properties into mathe - matical or phenomenological descriptions result in extremely complex expressions, requiring the use of 5-space mathematics and...reference 1. Applicattion of’quantity disitance req.uirements as requbEud by Naval regulations for this category hazard revealed that the location of the...or decrease with height. A decrease of temperature and soind speed wt,.h height is called a gradient . Strong pror gations would result frow large

  6. The KnownLeaf literature curation system captures knowledge about Arabidopsis leaf growth and development and facilitates integrated data mining

    Directory of Open Access Journals (Sweden)

    Dóra Szakonyi

    2015-05-01

    DATA: The presented work was performed in the framework of the AGRON-OMICS project (Arabidopsis GRO wth Network integrating OMICS technologies supported by European Commission 6th Framework Programme project (Grant number LSHG-CT-2006-037704. This is a data integration and data sharing portal collecting all the all the major results from the consortium. All data presented in our paper is available here. https://agronomics.ethz.ch/.

  7. Determination of oxygen content in steel using activation analysis with 14 MeV neutron

    International Nuclear Information System (INIS)

    Calado, C.E.

    1978-01-01

    In the quantitative analysis of oxygen in steel by fast neutron activation analysis the oxygen content is evaluated from the measured activity of 16 N produced. Steel s mples are irradiated in 14 MeV neutron flux. After irradiation the samples are pneumatically transfered to the counting terminal where activity is measured. Oxygen concentrations, are obtained by comparison with standards of specified oxygen content [pt

  8. Fast neutron activation analysis using short-lived radionuclides

    International Nuclear Information System (INIS)

    Salma, I.; Zemplen-Papp, E.

    1993-01-01

    Fast neutron activation analysis experiments were performed to investigate the analytical possibilities and prospective utilization of short-lived activation products. A rapid pneumatic transfer system for use with neutron generators has been installed and applied for detecting radionuclides with a half-life from ∼300 ms to 20 s. The transport time for samples of total mass of 1-4 g is between 130 and 160 ms for pressurized air of 0.1-0.4 MPa. The reproducibility of transport times is less than 2%. The employed method of correcting time-dependent counting losses is based on the virtual pulse generator principle. The measuring equipment consists of CAMAC modules and a special gating circuit. Typical time distributions of counting losses are presented. The same 14 elements were studied by the conventional activation method (single irradiation and single counting) by both a typical pneumatic transport system (run time 3 s) and the fast pneumatic transport facility. Furthermore, the influence of the cyclic activation technique on the elemental sensitivities was investigated. (author) 15 refs.; 5 figs.; 3 tabs

  9. Determination of cadmium in environmental materials by fast neutron activation analysis

    International Nuclear Information System (INIS)

    Esprit, M.; Vandecasteele, C.; Hoste, J.

    1986-01-01

    Cadmium is determined by activation analysis with fast neutrons, obtained by irradiation of a thick beryllium target with 14.5-MeV deuterons. Cadmium-111m is separated by liquid-liquid extraction with zinc diethyldithiocarbamate in chloroform and measured with a Ge(Li) γ-spectrometer. For low concentrations, cadmium is precipitated as cadmium ammonium phosphate after the extraction. NBS and BCR reference materials were analyzed: for concentrations between 3 and 500 μg g -1 , the relative standard deviation ranges from 5 to 3%. The results obtained for sewage sludge are compared with those obtained by reactor neutron activation analysis. (Auth.)

  10. Study of some environmental problem in egypt using neutron activation analysis techniques

    International Nuclear Information System (INIS)

    El-Karim, A.H.M.G.

    2003-01-01

    this thesis deals with the investigation of the possibility of using the new (second) egyptian research reactor (ETRR-2) at Inshas (22 MW) for the neutron activation analysis (ANN) of trace elements, particularly in air dust, collected from cairo and some other cities of egypt. in this concern chapter 1 gives an introduction about the activation methods in general, describing the various techniques used and a comparison of the methods with other instrumental methods of analysis . as a main classification, the neutron activation methods involve prompt γ-ray NAA and delayed γ-ray NAA; cyclic NAA (repeated activation) was also outlined. the methodology of NAA involves the absolute method, the relative method and the mono standard (single comparator) method , which is in between the absolute and relative methods

  11. Current status of neutron activation analysis in HANARO Research Reactor

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Sohn, Jae Min

    2003-01-01

    The facilities for neutron activation analysis in the HANARO (Hi-flux Advanced Neutron Application Research Reactor) are described and the main applications of NAA (Neutron Activation Analysis) are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system were installed at three irradiation holes of HANARO at the end of 1995. The performance of the NAA facility was examined to identify the characteristics of the tube transfer system, irradiation sites and custom-made polyethylene irradiation capsule. The available thermal neutron fluxes at irradiation sites are in the range of 3 x 10 13 - 1 x 10 14 n/cm 2 ·s and cadmium ratios are in 15 - 250. For an automatic sample changer for gamma-ray counting, a domestic product was designed and manufactured. An integrated computer program (Labview) to analyse the content was developed. In 2001, PGNAA (Prompt Gamma Neutron Activation Analysis) facility has been installed using a diffracted neutron beam of ST1. NAA has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials, and various polymers for research and development. The improvement of analytical procedures and establishment of an analytical quality control and assurance system were studied. Applied research and development for the environment, industry and human health by NAA and its standardization were carried out. For the application of the KOLAS (Korea Laboratory Accreditation Scheme), evaluation of measurement uncertainty and proficiency testing of reference materials were performed. Also to verify the reliability and to validate analytical results, intercomparison studies between laboratories were carried out. (author)

  12. Provenience studies using neutron activation analysis: the role of standardization

    International Nuclear Information System (INIS)

    Harbottle, G.

    1980-01-01

    This paper covers the historical background of chemical analysis of archaeological artifacts which dates back to 1790 to the first application of neutron activation analysis to archaeological ceramics and goes on to elaborate on the present day status of neutron activation analysis in provenience studies, and the role of standardization. In principle, the concentrations of elements in a neutron-activated specimen can be calculated from an exact knowledge of neutron flux, its intensity, duration and spectral (energy) distribution, plus an exact gamma ray count calibrated for efficiency, corrected for branching rates, etc. However, in practice it is far easier to compare one's unknown to a standard of known or assumed composition. The practice has been for different laboratories to use different standards. With analyses being run in the thousands throughout the world, a great benefit would be derived if analyses could be exchanged among all users and/or generators of data. The emphasis of this paper is on interlaboratory comparability of ceramic data; how far are we from it, what has been proposed in the past to achieve this goal, and what is being proposed. All of this may be summarized under the general heading of Analytical Quality Control - i.e., how to achieve precise and accurate analysis. The author proposes that anyone wishing to analyze archaeological ceramics should simply use his own standard, but attempt to calibrate that standard as nearly as possible to absolute (i.e., accurate) concentration values. The relationship of Analytical Quality Control to provenience location is also examined

  13. Current status of neutron activation analysis in HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Moon, Jong Hwa; Sohn, Jae Min [Korea Atomic Energy Research Institute, Daejeon (Korea)

    2003-03-01

    The facilities for neutron activation analysis in the HANARO (Hi-flux Advanced Neutron Application Research Reactor) are described and the main applications of NAA (Neutron Activation Analysis) are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system were installed at three irradiation holes of HANARO at the end of 1995. The performance of the NAA facility was examined to identify the characteristics of the tube transfer system, irradiation sites and custom-made polyethylene irradiation capsule. The available thermal neutron fluxes at irradiation sites are in the range of 3 x 10{sup 13} - 1 x 10{sup 14} n/cm{sup 2}{center_dot}s and cadmium ratios are in 15 - 250. For an automatic sample changer for gamma-ray counting, a domestic product was designed and manufactured. An integrated computer program (Labview) to analyse the content was developed. In 2001, PGNAA (Prompt Gamma Neutron Activation Analysis) facility has been installed using a diffracted neutron beam of ST1. NAA has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials, and various polymers for research and development. The improvement of analytical procedures and establishment of an analytical quality control and assurance system were studied. Applied research and development for the environment, industry and human health by NAA and its standardization were carried out. For the application of the KOLAS (Korea Laboratory Accreditation Scheme), evaluation of measurement uncertainty and proficiency testing of reference materials were performed. Also to verify the reliability and to validate analytical results, intercomparison studies between laboratories were carried out. (author)

  14. Comparison of neutron activation analysis with other instrumental methods for elemental analysis of airborne particulate matter

    International Nuclear Information System (INIS)

    Regge, P. de; Lievens, F.; Delespaul, I.; Monsecour, M.

    1976-01-01

    A comparison of instrumental methods, including neutron activation analysis, X-ray fluorescence spectrometry, atomic absorption spectrometry and emission spectrometry, for the analysis of heavy metals in airborne particulate matter is described. The merits and drawbacks of each method for the routine analysis of a large number of samples are discussed. The sample preparation technique, calibration and statistical data relevant to each method are given. Concordant results are obtained by the different methods for Co, Cu, Ni, Pb and Zn. Less good agreement is obtained for Fe, Mn and V. The results are not in agreement for the elements Cd and Cr. Using data obtained on the dust sample distributed by Euratom-ISPRA within the framework of an interlaboratory comparison, the accuracy of each method for the various elements is estimated. Neutron activation analysis was found to be the most sensitive and accurate of the non-destructive analysis methods. Only atomic absorption spectrometry has a comparable sensitivity, but requires considerable preparation work. X-ray fluorescence spectrometry is less sensitive and shows biases for Cr and V. Automatic emission spectrometry with simultaneous measurement of the beam intensities by photomultipliers is the fastest and most economical technique, though at the expense of some precision and sensitivity. (author)

  15. Neutron activation analysis - an aid to forensic science

    International Nuclear Information System (INIS)

    Chattopadhyay, N.; Basu, A.K.; Tripathi, A.B.R.; Bhadkambekar, C.A.; Shukla, S.K.

    2006-01-01

    Forensic Science is oriented towards the examination of evidence specimens, collected from a scene of crime in order to establish the link between the criminal and the crime. This science therefore has a profound role to play in criminal justice delivery system. The importance of neutron activation analysis (NAA) as a specialised technique to aid crime investigation has emerged and has been recognised

  16. Gamma Activation Analysis in the Havana Bay superficial sediments

    International Nuclear Information System (INIS)

    Lopez, N.; Gelen, A.; Diaz Riso, O.; Manso, M.V.; Simon, M.J.; Maslov, A.G.; Gustova, M.V.; Beltran, J.; Soto, J.

    2003-01-01

    A preliminary study of 26 elements of Havana Bay superficial sediments were made using Gamma Activation Analysis. Samples from five zones of Havana Bay were analyzed. The results show a close interrelation between the concentration levels of the studied elements and the contaminant sources

  17. [Operating cost analysis of anaesthesia: activity based costing (ABC analysis)].

    Science.gov (United States)

    Majstorović, Branislava M; Kastratović, Dragana A; Vučović, Dragan S; Milaković, Branko D; Miličić, Biljana R

    2011-01-01

    Cost of anaesthesiology represent defined measures to determine a precise profile of expenditure estimation of surgical treatment, which is important regarding planning of healthcare activities, prices and budget. In order to determine the actual value of anaestesiological services, we started with the analysis of activity based costing (ABC) analysis. Retrospectively, in 2005 and 2006, we estimated the direct costs of anestesiological services (salaries, drugs, supplying materials and other: analyses and equipment.) of the Institute of Anaesthesia and Resuscitation of the Clinical Centre of Serbia. The group included all anesthetized patients of both sexes and all ages. We compared direct costs with direct expenditure, "each cost object (service or unit)" of the Republican Healthcare Insurance. The Summary data of the Departments of Anaesthesia documented in the database of the Clinical Centre of Serbia. Numerical data were utilized and the numerical data were estimated and analyzed by computer programs Microsoft Office Excel 2003 and SPSS for Windows. We compared using the linear model of direct costs and unit costs of anaesthesiological services from the Costs List of the Republican Healthcare Insurance. Direct costs showed 40% of costs were spent on salaries, (32% on drugs and supplies, and 28% on other costs, such as analyses and equipment. The correlation of the direct costs of anaestesiological services showed a linear correlation with the unit costs of the Republican Healthcare Insurance. During surgery, costs of anaesthesia would increase by 10% the surgical treatment cost of patients. Regarding the actual costs of drugs and supplies, we do not see any possibility of costs reduction. Fixed elements of direct costs provide the possibility of rationalization of resources in anaesthesia.

  18. Research in the fields of radiochemistry and activation analysis using the LENA TRIGA nuclear plant

    International Nuclear Information System (INIS)

    Maxia, V.; Meloni, S.; Stella, R.; Brandone, A.

    1972-01-01

    In the past two years most of the research effort at the Radiochemistry Laboratory and National Research Council Centre for Radiochemistry and Activation Analysis has been devoted to research and development of activation analysis using the TRIGA Mark II LENA reactor of the University of Pavia. Pile neutrons have been used both in steady state and pulse mode, in the determination of oxygen in non ferrous materials. Neutron activation has been applied to the determination of some atmospheric particulate pollutants. Another field, in which activation analysis has been applied, is forensic research. Methods have been developed for the determination of antimony, barium and copper in gunpowder residues. By using inorganic materials such as molybdenum dibromide, zinc ferrocyanide and cadmium metal in granular form it was possible to set up simple chemical procedures in the activation analysis of trace amounts of noble metals in metallic matrices (high purity nickel and copper), geochemical materials (rocks and meteorites) and biological materials (orchard leaves). Neutron activation analysis was also used to investigate on the extraction of the platinum group metals from iodide and thiocyanate solutions at low concentrations

  19. An analysis of a board game as a treatment activity.

    Science.gov (United States)

    Neistadt, M E; McAuley, D; Zecha, D; Shannon, R

    1993-02-01

    Occupational therapists often use tabletop board games in treatment to help adult clients with physical disabilities improve the perceptual, cognitive, sensory, and fine motor skill components of occupational behavior. Detailed activity analyses of these types of activities, including performance norms, are not available in the occupational therapy literature. Such analyses would help therapists consider the multiple skill demands of tabletop games and allow more systematic grading of these treatment activities. This paper presents a model for analyzing therapeutic activities in relation to relevant motor learning and cognitive-perceptual literature. Included in this analysis are a description of the activity, examination of its component skills and of the qualitative features of activity performance, suggestions for grading and for treatment goals, and some preliminary performance standards derived from a pilot study of 18 adults without physical disabilities. The issue of transfer of skills between games and functional activities is also discussed.

  20. Flipping the Audience Script: An Activity That Integrates Research and Audience Analysis

    Science.gov (United States)

    Lam, Chris; Hannah, Mark A.

    2016-01-01

    This article describes a flipped classroom activity that requires students to integrate research and audience analysis. The activity uses Twitter as a data source. In the activity, students identify a sample, collect customer tweets, and analyze the language of the tweets in an effort to construct knowledge about an audience's values, needs, and…

  1. A concept analysis of voluntary active euthanasia.

    Science.gov (United States)

    Guo, Fenglin

    2006-01-01

    Euthanasia has a wide range of classifications. Confusion exists in the application of specific concepts to various studies. To analyze the concept of voluntary active euthanasia using Walker and Avant's concept analysis method. A comprehensive literature review from various published literature and bibliographies. Clinical, ethical, and policy differences and similarities of euthanasia need to be debated openly, both within the medical profession and publicly. Awareness of the classifications about euthanasia may help nurses dealing with "end of life issues" properly.

  2. Neutron activation analysis and atomic absorption spectrophotometry for the analysis of fresh, pasteurised and powder milk

    International Nuclear Information System (INIS)

    Wasim, M.; Rehman, S.; Arif, M.; Fatima, I.; Zaidi, J.H.

    2012-01-01

    This study shows the application of semi-absolute k 0 instrumental neutron activation analysis (k 0 -INAA), epithermal neutron activation analysis (ENAA) and atomic absorption spectrophotometry (AAS) for the determination of 21 elements (Br, Ca, Cl, Co, Cr, Cs, Cu, Fe, Hf, I, K, Mg, Mn, Na, Ni, P, Pb, Rb, Sc Sr, and Zn) in different types of milk samples. The ENAA was required for the determination of iodine, AAS for Cu, Ni and Pb and the rest of the elements were measured by k 0 -INAA. Thirteen elements (Br, Ca, Cl, Cs, Cu, Fe, K, Mg, Na, P, Rb, Sr and Zn) were identified in all milk samples. Ni was detected in eleven and Pb in two samples. Concentrations of most of the elements were within the ranges of the world reported data. The data was further explored by principal component analysis to find relationships between samples and elements. (orig.)

  3. Neutron activation analysis of limestone objects

    International Nuclear Information System (INIS)

    Meyers, P.; Van Zelst, L.

    1977-01-01

    The elemental composition of samples from limestone objects were determined by neutron activation analysis to investigate whether this technique can be used to distinguish between objects made of limestone from different sources. Samples weighing between 0.2-2 grams were obtained by drilling from a series of ancient Egyptian and medieval Spanish objects. Analysis was performed on aliquots varying in weight from 40-100 milligrams. The following elements were determined quantitatively: Na, K, Rb, Cs, Ba, Sc, La, Ce, Sm, Eu, Hf, Th, Ta, Cr, Mn, Fe, Co and Zn. The data on Egyptian limestones indicate that, because of the inhomogeneous nature of the stone, 0.2-2 gram samples may not be representative of an entire object. Nevertheless, multivariate statistical methods produced a clear distinction between objects originating from the Luxor area (ancient Thebes) and objects found north of Luxor. The Spanish limestone studied appeared to be more homogeneous. Samples from stylistically related objects have similar elemental compositions while relative large differences were observed between objects having no relationship other than the common provenance of medieval Spain. (orig.) [de

  4. Quality assurance in neutron activation analysis

    International Nuclear Information System (INIS)

    Heydorn, K.

    1984-01-01

    As a potential reference method, neutron activation analysis does not have to rely on other reference materials to ascertain the quality of analytical results. The fundamental characteristics of the method with the clear separation between irradiation, processing, and counting makes possible the estimation of uncertainties of individual results from a priori assumptions. Such estimates of the standard deviation from a series of independent sources of variation are compared with the a posteriori variability of replicate determinations in order to ascertain that the analytical method is in a state of statistical control. This Analysis of Precision tests the absence of unknown errors by means of a statistic T, which is closely approximated by a chi-square distribution. In this manner an evaluation is made of a commercially available computer program for peak evaluation in γ-spectrometry, as well as of other factors affecting the precision and accuracy of the counting process. An attempt is also made to determine sampling constants of one gram or less in a candidate biological reference material

  5. Neutron activation analysis of biological material

    International Nuclear Information System (INIS)

    Kucera, J.; Simkova, M.; Obrusnik, I.

    1985-01-01

    The possibilities are briefly summed up of usino. NAA (neutron activation analysis) for determining element traces in foodstuffs and their intake by organisms, for monitoring changes in the content of important trace elements in tissues and body fluids owing to environmental pollution, for verifying the results of other analytical techniques and for certifying the content of element traces in reference materials. Examples are given of the use of NAA, and the results are summed up of the determination of Cd, Mn and Zn in biological reference materials NBS SRM-1577, Bovine Liver, Bowen's Kale, IAEA Milk Powder A-11 and IAEA Animal Muscle H-4. (E.S.)

  6. Multi-element analysis of emeralds and associated rocks by k0 neutron activation analysis

    International Nuclear Information System (INIS)

    Acharya, R.N.; Mondal, R.K.; Burte, P.P.; Nair, A.G.C.; Reddy, N.B.Y.; Reddy, L.K.; Reddy, A.V.R.; Manohar, S.B.

    2000-01-01

    Multi-element analysis was carried out in natural emeralds, their associated rocks and one sample of beryl obtained from Rajasthan, India. The concentrations of 21 elements were assayed by Instrumental Neutron Activation Analysis using the k 0 method (k 0 INAA method) and high-resolution gamma ray spectrometry. The data reveal the segregation of some elements from associated (trapped and host) rocks to the mineral beryl forming the gemstones. A reference rock standard of the US Geological Survey (USGS BCR-1) was also analysed as a control of the method

  7. Multi trace element analysis of dry biological materials by neutron activation analysis including a chemical group separation

    International Nuclear Information System (INIS)

    Weers, C.A.

    1980-01-01

    The principles of activation analysis and the practical aspects of neutron activation analysis are outlined. The limits which are set to accuracy and precision are defined. The description of the evaporation process is summarised in terms of the half-volume. This quantity is then used to define the resolving power. The formulation is checked by radiotracer experiments. Dried animal blood is used as the testing material. The pretreatment of the samples and (the development of) the destruction-evaporation apparatus is described. Four successive devices were built and tested. The development of the successive adsorption steps with active charcoal, Al 2 O 3 and coprecipitation with Fe(OH) 3 is presented. Seven groups of about 25 elements in total can be determined this way. The results obtained for standard reference materials are summarized and compared with literature data. (Auth.)

  8. Determination of ancient ceramics reference material by neutron activation analysis

    International Nuclear Information System (INIS)

    Li Huhou; Sun Jingxin; Wang Yuqi; Lu Liangcai

    1986-01-01

    Contents of trace elements in the reference material of ancient ceramics (KPS-1) were determined by means of activation analysis, using thermal neutron irradiation produced in nuclear reactor. KPS-1 favoured the analysis of ancient ceramics because it had not only many kinds of element but also appropriate contents of composition. The values presented here are reliable within the experimental precision, and have shown that the reference material had a good homogeneity. So KPS-1 can be used as a suitable reference material for the ancient ceramics analysis

  9. Analysis of alternatives for immobilized low activity waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Burbank, D.A.

    1997-10-28

    This report presents a study of alternative disposal system architectures and implementation strategies to provide onsite near-surface disposal capacity to receive the immobilized low-activity waste produced by the private vendors. The analysis shows that a flexible unit strategy that provides a suite of design solutions tailored to the characteristics of the immobilized low-activity waste will provide a disposal system that best meets the program goals of reducing the environmental, health, and safety impacts; meeting the schedule milestones; and minimizing the life-cycle cost of the program.

  10. Analysis of alternatives for immobilized low-activity waste disposal

    International Nuclear Information System (INIS)

    Burbank, D.A.

    1997-01-01

    This report presents a study of alternative disposal system architectures and implementation strategies to provide onsite near-surface disposal capacity to receive the immobilized low-activity waste produced by the private vendors. The analysis shows that a flexible unit strategy that provides a suite of design solutions tailored to the characteristics of the immobilized low-activity waste will provide a disposal system that best meets the program goals of reducing the environmental, health, and safety impacts; meeting the schedule milestones; and minimizing the life-cycle cost of the program

  11. Determination of copper in some Myanmar indigenous medicines by neutron activation analysis

    International Nuclear Information System (INIS)

    Myint-U; Kyi Kyi San

    1994-01-01

    Copper was determined in two Myanmar indigenous medicines by neutron activation analysis using an Am(Be) radionuclide neutron source. The activity of 511 keV peak of the 64 Cu was measured. (author) 2 refs.; 2 tabs

  12. Analysis by Neutron activation of the Calakmul jadeite mask

    International Nuclear Information System (INIS)

    Alemon A, E.; Herrera V, L.

    1998-01-01

    It is very important to know the elemental composition of archaeological materials with the purpose to find relations that allow to establish their origin standards. the origin and present localization of pre hispanic archaeological pieces can lead to the determination of commercial routes and of technology transfer among different ancient cultures. In the present work it has been realized a systematic analysis using the Instrumental neutron activation analysis technique of three samples obtained from Calakmul jadeite mask, tomb I, that in addition to give a composition of constituent and trace elements detected by this technique it has leaded to establish an applicable methodology to the routine analysis of ceramics of historical interest. (Author)

  13. PETRA - an Activity-based Approach to Travel Demand Analysis

    DEFF Research Database (Denmark)

    Fosgerau, Mogens

    2001-01-01

    This paper concerns the PETRA model developed by COWI in a project funded by the Danish Ministry of Transport, the Danish Transport Council and the Danish Energy Research Program. The model provides an alternative approach to activity based travel demand analysis that excludes the time dimension...

  14. Analysis of promoter activity in transgenic plants by normalizing ...

    Indian Academy of Sciences (India)

    Analysis of promoter activity in transgenic plants by normalizing expression with a reference gene: anomalies due to the influence of the test promoter on the reference promoter. Simran Bhullar Suma Chakravarthy Deepak Pental Pradeep Kumar Burma. Articles Volume 34 Issue 6 December 2009 pp 953-962 ...

  15. Impact of insurance sector activity on economic growth – A meta-analysis

    Directory of Open Access Journals (Sweden)

    Zuzana Richterková

    2013-01-01

    Full Text Available The aim of this study is to compute the overall effect size concerning the impact of insurance sector activity on economic growth. The connection of insurance activity and economic growth has been a widely investigated topic due to numerous papers and research attempts performed so far. The results, however, often differ among individual studies. Therefore a comprehensive analysis of the significance of causality from insurance activity, measured by insurance premium, to business cycle fluctuation, is well-required. Using 10 published and unpublished studies, we conduct a meta-analysis of the literature on the impact of insurance activity on economic growth. Insurance premium is taken as the measure of insurance activity. The combined significance test of individual t-statistics is employed. The calculation of the effect size allows understand the true effect relying on synthesis of so far published research with significantly higher amount of observations and better precision. Our results confirm positive effect of insurance activity on economic growth and are particularly important for policy makers who set the policy towards subjects in the insurance market.

  16. Multielement neutron-activation analysis of plants and fertilizers

    International Nuclear Information System (INIS)

    Srapenyants, R.A.; Saveliev, I.B.

    1977-01-01

    The development of an automated technique for simultaneous multielement activation analysis of plants and fertilizers for the macronutrient elements N, P, K, Ca, Mg, Cl, and Si is presented. The developed universal NAA is based on the installation manufactured and supplied by Sames, France. The components of the automatic installation for neutron activation analysis are: neutron generator; a pneumatic transfer system; a scintillation crystal detector; a spectrometer rack including a basic multichannel analyser; a control panel for the neutron generator and pneumatic transfer system; a computer and teletype. On the basis of analytical procedures, algorithms and software, the first automatic (computer based) installation for multielement analyses of plants and fertilizers has been completed and is in routine use in the agrochemical and plant breeding research program in the Soviet Union. The proposed technique together with the full automatic real-time process of measurement and processing of data by computer, provides a throughput of 250-500 samples (1250-2500 elements determinations) per 8-hour shift, with the accuracy of +-3%; for N and +-5%; for P, K, Mg, Cl and +-15% for Ca. (T.G.)

  17. Multielement analysis of Nigerian chewing sticks by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Asubiojo, O.I.; Guinn, V.P. (California Univ., Irvine (USA). Dept. of Chemistry); Okunuga, A. (California Polytechnic Univ., Pomona, CA (USA))

    1982-01-01

    In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as 'chewing sticks'. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis.

  18. Activities of the neutron activation analysis laboratory of the radiochemistry division of IPEN - CNEN/SP

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.

    1988-10-01

    Neutron activation analysis (NAA) is one of the relevant applications of nuclear research reactors. Due to the high neutron fluxes available in these reactors, an excellent sensitivity of analysis is attained for many elements. NAA is one of the most sensitive, precise and accurate analytical methods for trace element determination. NAA has been one of the main activities of the Radiochemistry Division of IPEN, since the beginning of the operation of the nuclear reactor IEA-R1. Most of the effort was devoted to research work, aimed to improvements in the method as well as to its applications to several kinds of matrixes (geological, biological, metallic, environmental, forensic). Besides, analytical services were also offered, to the CNEN, to industries, universities, mining companies and research institutes. In the present paper, a review is made of the research work being developed presently at the Radiochesmitry Division of IPEN. A discussion is also made of the planned expansion of the analytical services offered [pt

  19. Practical aspects of operating a neutron activation analysis laboratory

    International Nuclear Information System (INIS)

    1990-07-01

    This book is intended to advise in everyday practical problems related to operating a neutron activation analysis (NAA) laboratory. It gives answers to questions like ''what to use NAA for'', ''how to find relevant research problems'', ''how to find users for the technique'', ''how to estimate the cost of the analysis and how to finance the work'', ''how to organize the work in a rational way'' and ''how to perform the quality control''. It gives advice in choosing staff, equipment, and consumables and how to design facilities and procedures according to need and available resources. Potential applications of economic or environmental importance, reactor facilities, counting and measuring equipment of the lab, cooperation with other analytical groups and competitiveness of NAA are discussed by experienced analysts. The compiled 8 tables of data useful for neutron activation analysts are a valuable asset for research labs as well as industrial quality control units. Refs, figs and tabs

  20. Some examples of application of activation analysis to geology

    International Nuclear Information System (INIS)

    Schiltz, Jean-Claude

    1969-10-01

    For some fifteen years, activation analysis knows a considerable development. New facilities have become to be done to research workers and industrials by the fitting up of special laboratories near high flux reactors, in the Centre d'Etudes Nucleaires de Saclay and Grenoble. Other laboratories apparatus and particles sources are also used (fast neutrons generators, accelerators, etc. ). For some years, our laboratory contributed to study activation analysis applications to the field of Earth Sciences, particularly to geochemistry. Collecting here our experience and that of other laboratories, we have wished to give a glimpse of the diversity of applications and their as well economical as purely technical interest. This job, initial web of a conference done to the ADERP week in February 1969, doesn't obviously pretend to the exhaustion of the subject. We have simply chosen examples among the 'ost typical of our works and among those which have shown a bibliographical interest for us. (author) [fr

  1. Activation Analysis in Botany and Agriculture. Survey Paper

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, H. J.M. [University of Reading, Reading, Berks. (United Kingdom)

    1967-10-15

    The applications of activation analysis to the plant sciences are reviewed. In soil science the technique has only been used by a few workers but its potentialities are good. In particular, it offers a practical method of measuring the concentrations of trace elements such as Co, Cu, Mn, Mo, Se and Zn in the soil solution, which has rarely if ever been carried out by other techniques. It can also be used to determine phosphorus in the soil solution from phosphate-deficient soils, which cannot be done by current methods. In pure botany there have been many applications, mostly concerned with the behaviour of essential trace elements. The sensitivity of the method is adequate for the analysis not only of minute seeds but of embryos, endosperm and seed coats dissected from those seeds. Important developments include the use of the (n, {alpha}) reaction to determine boron, the (p, n) reaction to determine oxygen-18 in products of photosynthesis, and the detection of minute traces of organic phosphates on chromatograms. Most papers refer to seed plants, but there has been some work on fungi and about 20 elements have been determined in algae. Some of the latter elements could not have been determined by any other technique. There have been numerous applications in agriculture, though here the sensitivity of the method for essential trace elements has not been taken advantage of as much as might have been expected. There has, however, been particular interest in the determination of selenium, mainly because of the difficulty of using conventional analysis for the levels normally found in herbage and fertilizers. The determination of toxic residues, containing such elements as As, Br, CI, Hg or Ni is another application of great potential interest. In a recent intercomparison programme involving the analysis of standard kale, activation analysis has been shown to give results agreeing with those obtained by other techniques in all but one instance. The exception is the

  2. Droplet activation, separation, and compositional analysis: laboratory studies and atmospheric measurements

    Science.gov (United States)

    Hiranuma, N.; Kohn, M.; Pekour, M. S.; Nelson, D. A.; Shilling, J. E.; Cziczo, D. J.

    2011-10-01

    Droplets produced in a cloud condensation nuclei chamber (CCNC) as a function of supersaturation have been separated from unactivated aerosol particles using counterflow virtual impaction. Residual material after droplets were evaporated was chemically analyzed with an Aerodyne Aerosol Mass Spectrometer (AMS) and the Particle Analysis by Laser Mass Spectrometry (PALMS) instrument. Experiments were initially conducted to verify activation conditions for monodisperse ammonium sulfate particles and to determine the resulting droplet size distribution as a function of supersaturation. Based on the observed droplet size, the counterflow virtual impactor cut-size was set to differentiate droplets from unactivated interstitial particles. Validation experiments were then performed to verify that only droplets with sufficient size passed through the counterflow virtual impactor for subsequent analysis. A two-component external mixture of monodisperse particles was also exposed to a supersaturation which would activate one of the types (hygroscopic salts) but not the other (polystyrene latex spheres or adipic acid). The mass spectrum observed after separation indicated only the former, validating separation of droplets from unactivated particles. Results from ambient measurements using this technique and AMS analysis were inconclusive, showing little chemical differentiation between ambient aerosol and activated droplet residuals, largely due to low signal levels. When employing as single particle mass spectrometer for compositional analysis, however, we observed enhancement of sulfate in droplet residuals.

  3. Determination of copper in some Myanmar indigenous medicines by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Myint-U,; San, Kyi Kyi [Yangon Univ. (Myanmar). Dept. of Chemistry

    1994-09-15

    Copper was determined in two Myanmar indigenous medicines by neutron activation analysis using an Am(Be) radionuclide neutron source. The activity of 511 keV peak of the [sup 64]Cu was measured. (author) 2 refs.; 2 tabs.

  4. Eye movement analysis for activity recognition using electrooculography.

    Science.gov (United States)

    Bulling, Andreas; Ward, Jamie A; Gellersen, Hans; Tröster, Gerhard

    2011-04-01

    In this work, we investigate eye movement analysis as a new sensing modality for activity recognition. Eye movement data were recorded using an electrooculography (EOG) system. We first describe and evaluate algorithms for detecting three eye movement characteristics from EOG signals-saccades, fixations, and blinks-and propose a method for assessing repetitive patterns of eye movements. We then devise 90 different features based on these characteristics and select a subset of them using minimum redundancy maximum relevance (mRMR) feature selection. We validate the method using an eight participant study in an office environment using an example set of five activity classes: copying a text, reading a printed paper, taking handwritten notes, watching a video, and browsing the Web. We also include periods with no specific activity (the NULL class). Using a support vector machine (SVM) classifier and person-independent (leave-one-person-out) training, we obtain an average precision of 76.1 percent and recall of 70.5 percent over all classes and participants. The work demonstrates the promise of eye-based activity recognition (EAR) and opens up discussion on the wider applicability of EAR to other activities that are difficult, or even impossible, to detect using common sensing modalities.

  5. Short-time activation analysis with and without a 6LiD converter

    International Nuclear Information System (INIS)

    Grass, F.; Holzner, H.; Ritschel, A.; Ismail, S.S.; Dorner, J.

    1994-01-01

    Neutron activation analysis (NAA) at various irradiation and measurement systems of the Institute's TRIGA mark II reactor provides a choice of sample oriented analyzing systems. This is demonstrated on the analysis of waste products, on an analysis of the phase content of a high-T c superconductor and on a fluorine analysis in a standard reference material. (author) 17 refs.; 4 figs.; 5 tabs

  6. Development of digital gamma-activation autoradiography for analysis of samples of large area

    International Nuclear Information System (INIS)

    Kolotov, V.P.; Grozdov, D.S.; Dogadkin, N.N.; Korobkov, V.I.

    2011-01-01

    Gamma-activation autoradiography is a prospective method for screening detection of inclusions of precious metals in geochemical samples. Its characteristics allow analysis of thin sections of large size (tens of cm2), that favourably distinguishes it among the other methods for local analysis. At the same time, the activating field of the accelerator bremsstrahlung, displays a sharp intensity decrease relative to the distance along the axis. A method for activation dose ''equalization'' during irradiation of the large size thin sections has been developed. The method is based on the usage of a hardware-software system. This includes a device for moving the sample during the irradiation, a program for computer modelling of the acquired activating dose for the chosen kinematics of the sample movement and a program for pixel-by pixel correction of the autoradiographic images. For detection of inclusions of precious metals, a method for analysis of the acquired dose dynamics during sample decay has been developed. The method is based on the software processing pixel by pixel a time-series of coaxial autoradiographic images and generation of the secondary meta-images allowing interpretation regarding the presence of interesting inclusions based on half-lives. The method is tested for analysis of copper-nickel polymetallic ores. The developed solutions considerably expand the possible applications of digital gamma-activation autoradiography. (orig.)

  7. Development of digital gamma-activation autoradiography for analysis of samples of large area

    Energy Technology Data Exchange (ETDEWEB)

    Kolotov, V.P.; Grozdov, D.S.; Dogadkin, N.N.; Korobkov, V.I. [Russian Academy of Sciences, Moscow (Russian Federation). Vernadsky Inst. of Geochemistry and Analytical Chemistry

    2011-07-01

    Gamma-activation autoradiography is a prospective method for screening detection of inclusions of precious metals in geochemical samples. Its characteristics allow analysis of thin sections of large size (tens of cm2), that favourably distinguishes it among the other methods for local analysis. At the same time, the activating field of the accelerator bremsstrahlung, displays a sharp intensity decrease relative to the distance along the axis. A method for activation dose ''equalization'' during irradiation of the large size thin sections has been developed. The method is based on the usage of a hardware-software system. This includes a device for moving the sample during the irradiation, a program for computer modelling of the acquired activating dose for the chosen kinematics of the sample movement and a program for pixel-by pixel correction of the autoradiographic images. For detection of inclusions of precious metals, a method for analysis of the acquired dose dynamics during sample decay has been developed. The method is based on the software processing pixel by pixel a time-series of coaxial autoradiographic images and generation of the secondary meta-images allowing interpretation regarding the presence of interesting inclusions based on half-lives. The method is tested for analysis of copper-nickel polymetallic ores. The developed solutions considerably expand the possible applications of digital gamma-activation autoradiography. (orig.)

  8. Clinical process analysis and activity-based costing at a heart center.

    Science.gov (United States)

    Ridderstolpe, Lisa; Johansson, Andreas; Skau, Tommy; Rutberg, Hans; Ahlfeldt, Hans

    2002-08-01

    Cost studies, productivity, efficiency, and quality of care measures, the links between resources and patient outcomes, are fundamental issues for hospital management today. This paper describes the implementation of a model for process analysis and activity-based costing (ABC)/management at a Heart Center in Sweden as a tool for administrative cost information, strategic decision-making, quality improvement, and cost reduction. A commercial software package (QPR) containing two interrelated parts, "ProcessGuide and CostControl," was used. All processes at the Heart Center were mapped and graphically outlined. Processes and activities such as health care procedures, research, and education were identified together with their causal relationship to costs and products/services. The construction of the ABC model in CostControl was time-consuming. However, after the ABC/management system was created, it opened the way for new possibilities including process and activity analysis, simulation, and price calculations. Cost analysis showed large variations in the cost obtained for individual patients undergoing coronary artery bypass grafting (CABG) surgery. We conclude that a process-based costing system is applicable and has the potential to be useful in hospital management.

  9. Study of dietary supplements compositions by neutron activation analysis at the VR-1 training reactor

    Science.gov (United States)

    Stefanik, Milan; Rataj, Jan; Huml, Ondrej; Sklenka, Lubomir

    2017-11-01

    The VR-1 training reactor operated by the Czech Technical University in Prague is utilized mainly for education of students and training of various reactor staff; however, R&D is also carried out at the reactor. The experimental instrumentation of the reactor can be used for the irradiation experiments and neutron activation analysis. In this paper, the neutron activation analysis (NAA) is used for a study of dietary supplements containing the zinc (one of the essential trace elements for the human body). This analysis includes the dietary supplement pills of different brands; each brand is represented by several different batches of pills. All pills were irradiated together with the standard activation etalons in the vertical channel of the VR-1 reactor at the nominal power (80 W). Activated samples were investigated by the nuclear gamma-ray spectrometry technique employing the semiconductor HPGe detector. From resulting saturated activities, the amount of mineral element (Zn) in the pills was determined using the comparative NAA method. The results show clearly that the VR-1 training reactor is utilizable for neutron activation analysis experiments.

  10. Neutron activation analysis at CDTN/CNEN using the IPR-R1 Triga Mark I reactor

    International Nuclear Information System (INIS)

    Menezes, Maria Angela de B.C.; Maretti Junior, Fausto; Kastner, Geraldo Frederico; Amaral, Angela Maria; Souza, Wagner de

    2009-01-01

    This paper describes in summary the activities developed by the Laboratory for Neutron Activation Analysis since the starting up of the IPR-R1 TRIGA Mark I research reactor in 1960. This Laboratory is located at Centro de Desenvolvimento da Tecnologia Nuclear (Nuclear Technology Development Centre) / Comissao Nacional de Energia Nuclear (Brazilian Commission for Nuclear Energy), CDTN/CNEN. The activities of the Laboratory comprise the delayed fission neutron activation analysis, instrumental (comparative and parametric methods) and radiochemical / chemical methods. These methods are responsible for significant percentage of CDTN's analytical demand, meeting the clients' analytical needs and researches developed by the Laboratory, by CDTN and by other institutions. Over the years the work has been linked to the goals of the country and the institutions. Nowadays the neutron activation analysis is responsible for 70% of the analytical demand and the k 0 - Instrumental method for 80% of this demand answering clients' request and researches. In Brazil, CDTN is the only Institute that fully masters the Instrumental Neutron Activation Analysis k 0 -method using its own nuclear reactor. (author)

  11. Cluster analysis of activity-time series in motor learning

    DEFF Research Database (Denmark)

    Balslev, Daniela; Nielsen, Finn Å; Futiger, Sally A

    2002-01-01

    Neuroimaging studies of learning focus on brain areas where the activity changes as a function of time. To circumvent the difficult problem of model selection, we used a data-driven analytic tool, cluster analysis, which extracts representative temporal and spatial patterns from the voxel......-time series. The optimal number of clusters was chosen using a cross-validated likelihood method, which highlights the clustering pattern that generalizes best over the subjects. Data were acquired with PET at different time points during practice of a visuomotor task. The results from cluster analysis show...

  12. Active Greens : An Analysis of the Determinants of Green Party Members' Activism in Environmental Movements

    NARCIS (Netherlands)

    Botetzagias, Iosif; van Schuur, Wijbrandt

    This article investigates green party members' activism in the environmental movement and tests how a number of predictors, theoretically suggested in the past yet rarely empirically tested, can account for it. The authors' analysis is based on an extensive data set of members of 15 green parties in

  13. Overview of current activities relevant to structural analysis on LMFBR in Japan

    International Nuclear Information System (INIS)

    Ichimiya, Masakazu

    1983-01-01

    This paper presents the structural analysis activities on LMFBR in Japan. The structural analysis activities on LMFBR in Japan have been made mainly toward the validation of the rules of high temperature structural design guide which is to be used for the design of Class 1 components for elevated temperature service of the prototype fast breeder reactor, Monju. Main features of these analyses are as follows. (1) Since the design by elastic analysis is intended in the high temperature structural design guide of Monju, a large progress has been made in the bounding technique for high temperature inelastic behaviors, particularly the elastic follow-up. (2) There has been a progress in the clarification of the creep behavior in order to evaluate creep damage adequately. (3) Analysis techniques and design rules for piping have been developed with considerable emphasis. In addition, buckling analyses were performed considering the thin structures with low internal pressure in Monju components. Further test and analysis were made on ratcheting. (author)

  14. The instrumental neutron-activation analysis of granites from the Bushveld Complex

    International Nuclear Information System (INIS)

    Watterson, J.I.W.

    1978-01-01

    Three methods of instrumental neutron-activation analysis, 14MeV, reactor thermal, and reactor epithermal, are compared for the analysis of granites form the Bushveld Complex. A total of 34 elements can be determined in the granites by these methods. Samples from the Zaaiplaats area were analysed by thermal neutron activation, and 22 elements were determined in all of them. These elements were used to distinguish between the mineralized Bobbejaankop and Lease granites and the Main granite by the use of multivariate statistics. The Bobbejaankop granite appears as a more-differentaited rock carrying greater amounts of the incompatible elements than does the Main granite [af

  15. Analysis of DOE international environmental management activities

    Energy Technology Data Exchange (ETDEWEB)

    Ragaini, R.C.

    1995-09-01

    The Department of Energy`s (DOE) Strategic Plan (April 1994) states that DOE`s long-term vision includes world leadership in environmental restoration and waste management activities. The activities of the DOE Office of Environmental Management (EM) can play a key role in DOE`s goals of maintaining U.S. global competitiveness and ensuring the continuation of a world class science and technology community. DOE`s interest in attaining these goals stems partly from its participation in organizations like the Trade Policy Coordinating Committee (TPCC), with its National Environmental Export Promotion Strategy, which seeks to strengthen U.S. competitiveness and the building of public-private partnerships as part of U.S. industrial policy. The International Interactions Field Office task will build a communication network which will facilitate the efficient and effective communication between DOE Headquarters, Field Offices, and contractors. Under this network, Headquarters will provide the Field Offices with information on the Administration`s policies and activities (such as the DOE Strategic Plan), interagency activities, as well as relevant information from other field offices. Lawrence Livermore National Laboratory (LLNL) will, in turn, provide Headquarters with information on various international activities which, when appropriate, will be included in reports to groups like the TPCC and the EM Focus Areas. This task provides for the collection, review, and analysis of information on the more significant international environmental restoration and waste management initiatives and activities which have been used or are being considered at LLNL. Information gathering will focus on efforts and accomplishments in meeting the challenges of providing timely and cost effective cleanup of its environmentally damaged sites and facilities, especially through international technical exchanges and/or the implementation of foreign-development technologies.

  16. Determination of Optimized Parameters for the Flexible Operation of a Biomass-Fueled, Microscale Externally Fired Gas Turbine (EFGT

    Directory of Open Access Journals (Sweden)

    Mathhar Bdour

    2016-10-01

    Full Text Available Biomass as a source of renewable energy is a promising solution for current problems in energy supply. Olive waste is considered as an interesting option, especially for Mediterranean countries. Within this paper, a microscale externally fired gas turbine (EFGT technology is presented as a decentralized power plant, within the range of 15 kWth, based on olive residues. It was modeled by Aspen Plus 8.6 software to provide a sufficient technical study for such a plant. Optimized parameters for pressure ratio and turbine air-mass flow have been mapped for several loads to provide information for process control. For all cases, mechanical output, efficiency curves, and back-work ratio have been calculated. Using this information, typical plant sizes and an example of power production are discussed. Additionally, achievable energy production from olive waste is estimated on the basis of this data. The results of this study show that such a plant has an electrical efficiency of 5%–17%. This variation is due to the examination being performed under several combustion temperatures, actual load, heat exchanger temperatures, and heat transfer efficiency. A cost estimation of the discussed system showed an estimated capital cost of 33,800 to 65,300 € for a 15 kWth system.

  17. Simultaneous multi-element analysis of some edible pulses using neutron activation analysis

    International Nuclear Information System (INIS)

    El-Sweify, F.H.; Metwally, E.; Abdel-Khalik, H.

    2007-01-01

    This paper comprises the application of instrumental neutron activation analysis (INAA) for multi-element determination in some edible pulse samples. These edible pulses are usually daily used in the Egyptian kitchen. These were: anise, cumin, coriander, caraway, black cumin, white kidney bean, lupine, lentil, chickpea, broad bean, peanut, almond, and fenugreek. The pulses have been analyzed as dehulled pulses, in the case of legume and oil pulses with simultaneous analysis of their respective skins. The determined elements were: Ce, Co, Cr, Cs, Eu, Fe, Hf, Rb, Sb, Sc, Sr, Th and Zn. The element content in the dehulled pulses and their respective skins has been compared. Some elements were major or minor elements where others were trace elements. Standard reference materials were used to assure quality control, accuracy and precision of the technique. (author)

  18. Determination of Total Arsenic in Seaweed Products by Neutron Activation Analysis

    OpenAIRE

    Salim, N; Santoso, M; Damayanti, S; Kartawinata, T.G

    2013-01-01

    Seaweed products are widely consumed as food nowadays. Seaweeds are known to contain arsenic due to their capability to accumulate arsenic from the environment. Arsenic is a known toxic element which naturally occurs in the environment. Ingestion of high levels of arsenic will cause several adverse health effects. Arsenic in food occurs at trace concentrations which require sensitive and selective analysis methods to perform elemental analysis on. Validated neutron activation analysis was use...

  19. Charged particle activation analysis at RIKEN. Past, present and future

    International Nuclear Information System (INIS)

    Nozaki, T.

    2008-01-01

    From 1960s to 1980s many groups in the world actively studied and utilized charged particle activation analysis (CPAA) mainly for absolute determination of B, C, N, and O in high-purity substances, particularly semiconductor materials. Here, after a short historical note on CPAA, works of the author's group mainly at RIKEN are outlined and then his opinion is shown about how to anticipate on the present shrinking of CPAA. (author)

  20. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    Science.gov (United States)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-06-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  1. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    International Nuclear Information System (INIS)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-01-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  2. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    Energy Technology Data Exchange (ETDEWEB)

    Glascock, M. D.; Neff, H. [University of Missouri, Research Reactor Center (United States); Vaughn, K. J. [Pacific Lutheran University, Department of Anthropology (United States)

    2004-06-15

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  3. Comparison of different methods for activation analysis of geological and pedological samples: Reactor and epithermal neutron activation, relative and monostandard method

    International Nuclear Information System (INIS)

    Alian, A.; Sansoni, B.

    1980-04-01

    Using purely instrumental methods, a comparative study is presented on neutron activation analysis of rock and soil samples by whole reactor neutron spectrum and epithermal neutrons with both relative and monostandard procedures. The latter procedure used with epithermal neutron activation analysis of soil samples necessitated the use of the 'effective resonance integrals' which were determined experimentally. The incorporation of the #betta# factor, representing deviation of reactor epithermal neutron flux from 1/E law, is developed in the present work. The main criteria for the choice of one or more of the procedures studied for a given purpose are also indicated. Analysis of 15 trace elements, Ca and Fe in the standard Japanese granite JG-1 using monostandard epithermal neutron activation gave results in good agreement with the average literature values. (orig./RB) [de

  4. Bayesian Inference for Neural Electromagnetic Source Localization: Analysis of MEG Visual Evoked Activity

    International Nuclear Information System (INIS)

    George, J.S.; Schmidt, D.M.; Wood, C.C.

    1999-01-01

    We have developed a Bayesian approach to the analysis of neural electromagnetic (MEG/EEG) data that can incorporate or fuse information from other imaging modalities and addresses the ill-posed inverse problem by sarnpliig the many different solutions which could have produced the given data. From these samples one can draw probabilistic inferences about regions of activation. Our source model assumes a variable number of variable size cortical regions of stimulus-correlated activity. An active region consists of locations on the cortical surf ace, within a sphere centered on some location in cortex. The number and radi of active regions can vary to defined maximum values. The goal of the analysis is to determine the posterior probability distribution for the set of parameters that govern the number, location, and extent of active regions. Markov Chain Monte Carlo is used to generate a large sample of sets of parameters distributed according to the posterior distribution. This sample is representative of the many different source distributions that could account for given data, and allows identification of probable (i.e. consistent) features across solutions. Examples of the use of this analysis technique with both simulated and empirical MEG data are presented

  5. Analysis of foreign physical activity recommendations and guidelines for schools

    Directory of Open Access Journals (Sweden)

    Jan Pavelka

    2014-06-01

    Full Text Available Background:An adequate level of physical activity is an important part of children's lifestyle. The school environment plays a significant role in the area of interventions and strategies aiming to increase the level of physical activity in children. Objectives: The aim of this study is to analyse foreign recommendations leading to an increased level of physical activity in children and young people in Czech schools. Methods: A systematic search of studies published between 1988 and 2012 in the English language was completed in library databases Medline, Sport Discus, ProQuest, PsychInfo, ERIC, Wiley InterScience using the following keywords: physical activity, guidelines, recommendations, school and youth. The studies were then classified based on abstract and full-text analyses. Using a content analysis the expert team formulated the final recommendations to increase the level of physical activity for schools in the Czech Republic (CR. Results: Out of the total number of 91 identified foreign studies, 25 met the predetermined criteria and were used as a basis for formulating the recommendations. These foreign studies included 15 papers published in USA, two in Australia, two in Great Britain, two in Canada, one in the European Union, one in New Zealand and one international paper (an international consensus of experts from 34 countries. Based on the interpretation of the evidence, its justification and final consensus of the expert team, the basic areas for the recommendations to increase the level of physical activity in schools in the CR were identified. Conclusions: An analysis of foreign recommendations to increase the level of physical activity designed for schools and school facilities is one of the possible methods of formulating domestic recommendations. This recommendation could contribute to deeper understanding of the issue of the deteriorating lifestyle of school-aged children in the CR and reflects the efforts for improvement.

  6. Reconstruction of human brain spontaneous activity based on frequency-pattern analysis of magnetoencephalography data

    Directory of Open Access Journals (Sweden)

    Rodolfo R Llinas

    2015-10-01

    Full Text Available A new method for the analysis and localization of brain activity has been developed, based on multichannel magnetic field recordings, over minutes, superimposed on the MRI of the individual. Here, a high resolution Fourier Transform is obtained over the entire recording period, leading to a detailed multi-frequency spectrum. Further analysis implements a total decomposition of the frequency components into functionally invariant entities, each having an invariant field pattern localizable in recording space. The method, addressed as functional tomography, makes it possible to find the distribution of magnetic field sources in space. Here, the method is applied to the analysis of simulated data, to oscillating signals activating a physical current dipoles phantom, and to recordings of spontaneous brain activity in ten healthy adults. In the analysis of simulated data, 61 dipoles are localized with 0.7 mm precision. Concerning the physical phantom the method is able to localize three simultaneously activated current dipoles with 1 mm precision. Spatial resolution 3 mm was attained when localizing spontaneous alpha rhythm activity in ten healthy adults, where the alpha peak was specified for each subject individually. Co-registration of the functional tomograms with each subject’s head MRI localized alpha range activity to the occipital and/or posterior parietal brain region. This is the first application of this new functional tomography to human brain activity. The method successfully provides an overall view of brain electrical activity, a detailed spectral description and, combined with MRI, the localization of sources in anatomical brain space.

  7. Reconstruction of human brain spontaneous activity based on frequency-pattern analysis of magnetoencephalography data

    Science.gov (United States)

    Llinás, Rodolfo R.; Ustinin, Mikhail N.; Rykunov, Stanislav D.; Boyko, Anna I.; Sychev, Vyacheslav V.; Walton, Kerry D.; Rabello, Guilherme M.; Garcia, John

    2015-01-01

    A new method for the analysis and localization of brain activity has been developed, based on multichannel magnetic field recordings, over minutes, superimposed on the MRI of the individual. Here, a high resolution Fourier Transform is obtained over the entire recording period, leading to a detailed multi-frequency spectrum. Further analysis implements a total decomposition of the frequency components into functionally invariant entities, each having an invariant field pattern localizable in recording space. The method, addressed as functional tomography, makes it possible to find the distribution of magnetic field sources in space. Here, the method is applied to the analysis of simulated data, to oscillating signals activating a physical current dipoles phantom, and to recordings of spontaneous brain activity in 10 healthy adults. In the analysis of simulated data, 61 dipoles are localized with 0.7 mm precision. Concerning the physical phantom the method is able to localize three simultaneously activated current dipoles with 1 mm precision. Spatial resolution 3 mm was attained when localizing spontaneous alpha rhythm activity in 10 healthy adults, where the alpha peak was specified for each subject individually. Co-registration of the functional tomograms with each subject's head MRI localized alpha range activity to the occipital and/or posterior parietal brain region. This is the first application of this new functional tomography to human brain activity. The method successfully provides an overall view of brain electrical activity, a detailed spectral description and, combined with MRI, the localization of sources in anatomical brain space. PMID:26528119

  8. Neutron activation analysis of urinary calculi

    International Nuclear Information System (INIS)

    Souka, N.; Souka, S.; Sanad, W.; Abdel-Rassoul, A.A.

    1974-01-01

    Urinary calculi resulting from disorders in the urinary system are mostly composed of uric acid, urates, calcium oxalate, alkaline earth phosphates (Ca and Mg), triple phosphate (magnesium ammonium phosphate), calcium carbonate, cystine, xanthine, and traces of proteins. The determination of these macro-constituents has been carried out by different analytical procedures. No attempts however, have been reported regarding the determination of trace elements in urinary stones, apart from that of Herring et al., who investigated the consumption of strontium by urolithiasis patients. The present work is a non-destructive neutron activation analysis of urinary calculi, to search the variation in concentration of certain trace elements with the chemical composition of the calculus

  9. Protein determination in soya bean by fast neutron activation analysis

    International Nuclear Information System (INIS)

    Szegedi, S.; Mosbah, D.S.; Varadi, M.; Szaloki, I.

    1988-01-01

    For a non-destructive determination of the protein content in soya bean samples, 14-MeV neutron activation analysis was applied. To check the method, the results obtained by X-ray fluorescence analysis and the Kjeldahl procedure were compared. For pressed pellet samples of about 1 g with 15 min irradiation and 10 min measuring times the accuracy of the protein determination was found to be 15%. (author) 7 refs.; 4 figs.; 3 tabs

  10. Neutron activation analysis with k{sub 0}-standardisation : general formalism and procedure

    Energy Technology Data Exchange (ETDEWEB)

    Pomme, S.; Hardeman, F. [Centre de l`Etude de l`Energie Nucleaire, Mol (Belgium); Robouch, P.; Etxebarria, N.; Arana, G. [European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, Geel (Belgium)

    1997-09-01

    Instrumental neutron activation analysis (INAA) with k{sub 0}-standardisation is a powerful tool for multi-element analysis at a broad range of trace element concentrations. An overview is given of the basic principles, fundamental equations, and general procedure of this method. Different aspects of the description of the neutron activation reaction rate are discussed, applying the Hogdahl convention. A general activation-decay formula is derived and its application to INAA is demonstrated. Relevant k{sub 0}-definitions for different activation decay schemes are summarised and upgraded to cases of extremely high fluxes. The main standardisation techniques for INAA are discussed, emphasizing the k{sub 0}-standardisation. Some general aspects of the basic equipment and its calibration are discussed, such as the characterisation of the neutron field and the tuning of the spectrometry part. A method for the prediction and optimisation of the analytical performance of INAA is presented.

  11. Activation product analysis in a mixed sample containing both fission and neutron activation products

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Samuel S.; Clark, Sue B.; Eggemeyer, Tere A.; Finn, Erin C.; Hines, C. Corey; King, Mathew D.; Metz, Lori A.; Morley, Shannon M.; Snow, Mathew S.; Wall, Donald E.; Seiner, Brienne N.

    2017-11-02

    Activation analysis of gold (Au) is used to estimate neutron fluence resulting from a criticality event; however, such analyses are complicated by simultaneous production of other gamma-emitting fission products. Confidence in neutron fluence estimates can be increased by quantifying additional activation products such as platinum (Pt), tantalum (Ta), and tungsten (W). This work describes a radiochemical separation procedure for the determination of these activation products. Anion exchange chromatography is used to separate anionic forms of these metals in a nitric acid matrix; thiourea is used to isolate the Au and Pt fraction, followed by removal of the Ta fraction using hydrogen peroxide. W, which is not retained on the first anion exchange column, is transposed to an HCl/HF matrix to enhance retention on a second anion exchange column and finally eluted using HNO3/HF. Chemical separations result in a reduction in the minimum detectable activity by a factor of 287, 207, 141, and 471 for 182Ta, 187W, 197Pt, and 198Au respectively, with greater than 90% recovery for all elements. These results represent the highest recoveries and lowest minimum detectable activities for 182Ta, 187W, 197Pt, and 198Au from mixed fission-activation product samples to date, enabling considerable refinement in the measurement uncertainties for neutron fluences in highly complex sample matrices.

  12. Neutron activation analysis of trace elements in IAEA reference materials

    International Nuclear Information System (INIS)

    Cheema, M.N.; Hasany, S.M.; Hanif, I.; Chaudhry, M.S.; Qureshi, I.H.

    1978-09-01

    Analytical Chemistry Group of Nuclear Chemistry Division at PINSTECH has been participating in IAEA Intercomparison programme of analytical quality control since 1972. So far fifteen samples of a variety of materials received from the Agency have been analyzed for different minor and trace elements. Mostly destructive and non-destructive neutron activation analysis techniques have been used for elemental analysis. In this report the description of the samples and the experimental procedures employed have been mentioned. The results of elemental analysis have been reported and compared with IAEA values which are based on the average computed from the results of different participating laboratories. (authors)

  13. Combination of Accumulated Motion and Color Segmentation for Human Activity Analysis

    Directory of Open Access Journals (Sweden)

    Briassouli Alexia

    2008-01-01

    Full Text Available Abstract The automated analysis of activity in digital multimedia, and especially video, is gaining more and more importance due to the evolution of higher-level video processing systems and the development of relevant applications such as surveillance and sports. This paper presents a novel algorithm for the recognition and classification of human activities, which employs motion and color characteristics in a complementary manner, so as to extract the most information from both sources, and overcome their individual limitations. The proposed method accumulates the flow estimates in a video, and extracts "regions of activity" by processing their higher-order statistics. The shape of these activity areas can be used for the classification of the human activities and events taking place in a video and the subsequent extraction of higher-level semantics. Color segmentation of the active and static areas of each video frame is performed to complement this information. The color layers in the activity and background areas are compared using the earth mover's distance, in order to achieve accurate object segmentation. Thus, unlike much existing work on human activity analysis, the proposed approach is based on general color and motion processing methods, and not on specific models of the human body and its kinematics. The combined use of color and motion information increases the method robustness to illumination variations and measurement noise. Consequently, the proposed approach can lead to higher-level information about human activities, but its applicability is not limited to specific human actions. We present experiments with various real video sequences, from sports and surveillance domains, to demonstrate the effectiveness of our approach.

  14. Combination of Accumulated Motion and Color Segmentation for Human Activity Analysis

    Directory of Open Access Journals (Sweden)

    Ioannis Kompatsiaris

    2008-03-01

    Full Text Available The automated analysis of activity in digital multimedia, and especially video, is gaining more and more importance due to the evolution of higher-level video processing systems and the development of relevant applications such as surveillance and sports. This paper presents a novel algorithm for the recognition and classification of human activities, which employs motion and color characteristics in a complementary manner, so as to extract the most information from both sources, and overcome their individual limitations. The proposed method accumulates the flow estimates in a video, and extracts “regions of activity” by processing their higher-order statistics. The shape of these activity areas can be used for the classification of the human activities and events taking place in a video and the subsequent extraction of higher-level semantics. Color segmentation of the active and static areas of each video frame is performed to complement this information. The color layers in the activity and background areas are compared using the earth mover's distance, in order to achieve accurate object segmentation. Thus, unlike much existing work on human activity analysis, the proposed approach is based on general color and motion processing methods, and not on specific models of the human body and its kinematics. The combined use of color and motion information increases the method robustness to illumination variations and measurement noise. Consequently, the proposed approach can lead to higher-level information about human activities, but its applicability is not limited to specific human actions. We present experiments with various real video sequences, from sports and surveillance domains, to demonstrate the effectiveness of our approach.

  15. Active tourism as a tourist mode in expansion. Analysis of the supply of active tourism in Spain

    Directory of Open Access Journals (Sweden)

    Noelia Araújo Vila

    2012-06-01

    Full Text Available Parallel to the social and economic situation, where the experience economy is a reality, new tourist typologies are emerging in line with this demand experiential. Tourists are looking for sensations and emotions, so tourism sector has diversified its offer adapting to this desire. Active tourism appears, mode belonging to a larger field, nature tourism, a booming tourist type today by the increase of tourists interested in its activities. Therefore, this paper takes from this concept to below detail the types that are part of it, and finally it does an analysis of the active tourism offer of the Spanish territory, territory that is appropriate for this type of activity.

  16. Trace element determination in soft tissues of marine bivalves by activation analysis

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Nakano, Y.

    2003-01-01

    Trace elements in soft tissues of marine bivalves were determined by neutron activation analysis (NAA) and photon activation analysis (PAA). Elemental levels of Ag, As, Br, Co, Cu, Fe, I, Mn, Ni, Rb, Se, and Zn in the organs of giant ezoscallos, rock oysters, and giant crams were obtained. The metal-bound proteins were extracted from the mantles and hepatopancreases of rock oysters. By irradiating the fraction obtained by HPLC gel chromatography, the possibility for the existence of an Ag bound protein in the mantles was found. (author)

  17. High content analysis of phagocytic activity and cell morphology with PuntoMorph.

    Science.gov (United States)

    Al-Ali, Hassan; Gao, Han; Dalby-Hansen, Camilla; Peters, Vanessa Ann; Shi, Yan; Brambilla, Roberta

    2017-11-01

    Phagocytosis is essential for maintenance of normal homeostasis and healthy tissue. As such, it is a therapeutic target for a wide range of clinical applications. The development of phenotypic screens targeting phagocytosis has lagged behind, however, due to the difficulties associated with image-based quantification of phagocytic activity. We present a robust algorithm and cell-based assay system for high content analysis of phagocytic activity. The method utilizes fluorescently labeled beads as a phagocytic substrate with defined physical properties. The algorithm employs statistical modeling to determine the mean fluorescence of individual beads within each image, and uses the information to conduct an accurate count of phagocytosed beads. In addition, the algorithm conducts detailed and sophisticated analysis of cellular morphology, making it a standalone tool for high content screening. We tested our assay system using microglial cultures. Our results recapitulated previous findings on the effects of microglial stimulation on cell morphology and phagocytic activity. Moreover, our cell-level analysis revealed that the two phenotypes associated with microglial activation, specifically cell body hypertrophy and increased phagocytic activity, are not highly correlated. This novel finding suggests the two phenotypes may be under the control of distinct signaling pathways. We demonstrate that our assay system outperforms preexisting methods for quantifying phagocytic activity in multiple dimensions including speed, accuracy, and resolution. We provide a framework to facilitate the development of high content assays suitable for drug screening. For convenience, we implemented our algorithm in a standalone software package, PuntoMorph. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Radiochemical neutron activation analysis of gold in geochemical samples

    International Nuclear Information System (INIS)

    Zilliacus, R.

    1983-01-01

    A fast method for the radiochemical neutron activation analysis of gold in geochemical samples is described. The method is intended for samples having background concentrations of gold. The method is based on the dissolution of samples with hydrofluoric acid and aqua regia followed by the dissolution of the fluorides with boric acid and hydrochloric acid. Gold is then adsorbed on activated carbon by filtrating the solution through a thin carbon layer. The activity measurements are carried out using a Ge(Li)-detector and a multichannel analyzer. The chemical yields of the separation determined by reirradiation vary between 60 and 90%. The detection limit of the method is 0.2 ng/g gold in rock samples. USGS standard rocks and exploration reference materials are analyzed and the results are presented and compared with literature data. (author)

  19. Activation analysis of high pure quartz used as packing materials

    International Nuclear Information System (INIS)

    Luknitskij, V.A.; Morozov, B.A.

    1979-01-01

    A γ-spectrometric technique of neutron activation determination of microelements in quartz tubes used as a packing material for irradiation in reactors is reported. The analysis of 29 micro-admixtures in quartz tubes of USSR brands ''spectrtosil'' and ''KV'' was carried out. The γ-spectra of ''KV'' quartz irradiated by thermal and epithermal neutrons are presented. The activation by epithermal neutrons provides an activity gain for the nuclei whose resonance integral is high enough as compared to the activation cross-section with regard to thermal neutrons. The activation by epithermal neutrons permits additional determination of W, Cd, V, Th, Mn and Ni and provides for a substantial decrease in the activity of 24 Na, 42 K, 140 La, 46 Sc, 141 Ce, 51 Cr, and 59 Fe, which hinder the determination of the above-mentioned elements. The microelement composition of Soviet-made quartz varieties is compared to that of foreign-made quartz brands

  20. Trace elements in Australian opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Fardy, J.J.

    1994-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 42 samples of black, grey and white opals taken from a number of recognised Australian field. The results were evaluated to determine if a relationship exited between trace element content and opal colour. (author) 12 refs.; 12 figs.; 3 tabs

  1. Californium-252 neutron activation analysis of high-level processed nuclear tank waste

    International Nuclear Information System (INIS)

    Troyer, G.L.; Purcell, M.A.

    2000-01-01

    The basis for production assessment of the vitrification of Hanford nuclear fuel reprocessing wastes will be high-precision measurements of the elemental sodium content. However, the chemical analysis of both radioactive and nonradioactive components in nuclear waste can be challenged by high radiation dose rates. The dose rates compromise many analytical techniques as well as pose personnel dosimetry risks. In many cases, reduction of dose rates through dilution compromises the precision and sensitivity for certain key components. The use of neutron activation analysis (NAA) provides a method of analysis that avoids the need for dilutions or extensive sample preparation. These waste materials also contain trace quantities of fissionable isotopes, which, through neutron activation, can be estimated by delayed neutron counting of fissioned fragments

  2. Finite element analysis and validation of dielectric elastomer actuators used for active origami

    International Nuclear Information System (INIS)

    McGough, Kevin; Ahmed, Saad; Frecker, Mary; Ounaies, Zoubeida

    2014-01-01

    The field of active origami explores the incorporation of active materials into origami-inspired structures in order to serve as a means of actuation. Active origami-inspired structures capable of folding into complex three-dimensional (3D) shapes have the potential to be lightweight and versatile compared to traditional methods of actuation. This paper details the finite element analysis and experimental validation of unimorph actuators. Actuators are fabricated by adhering layers of electroded dielectric elastomer (3M VHB F9473PC) onto a passive substrate layer (3M Magic Scotch Tape). Finite element analysis of the actuators simulates the electromechanical coupling of the dielectric elastomer under an applied voltage by applying pressures to the surfaces of the dielectric elastomer where the compliant electrode (conductive carbon grease) is present. 3D finite element analysis of the bending actuators shows that applying contact boundary conditions to the electroded region of the active and passive layers provides better agreement to experimental data compared to modeling the entire actuator as continuous. To improve the applicability of dielectric elastomer-based actuators for active origami-inspired structures, folding actuators are developed by taking advantage of localized deformation caused by a passive layer with non-uniform thickness. Two-dimensional analysis of the folding actuators shows that agreement to experimental data diminishes as localized deformation increases. Limitations of using pressures to approximate the electromechanical coupling of the dielectric elastomer under an applied electric field and additional modeling considerations are also discussed. (paper)

  3. Antimicrobial activity and some phytochemical analysis of two extracts Vinca minor L.

    Directory of Open Access Journals (Sweden)

    Grujić Sandra M.

    2014-01-01

    Full Text Available This study investigated the antimicrobial activity as well as some phytochemical analysis of ethanol and diethyl ether extracts from plant species Vinca minor L. In vitro antimicrobial activity of extracts was studied on 20 strains of microorganisms (16 bacteria and four yeasts. Testing was performed by microdilution method and minimum inhibitory concentration (MIC and minimum microbicidal concentration (MMC were determined. The strongest antimicrobial activity was detected on G+ bacteria of the genus Bacillus. Tested G- bacteria and yeasts were not sensitive to the action of the extracts or the sensitivity was insignificant. Phytochemical analysis involved determining the amount of total phenolics, flavonoids and tannins, as well as the determination of antioxidant activity monitoring capability to neutralize free radicals (DPPH and the reductive potential. Phytochemical examination indicates that the total phenolic compounds were more in the ethanolic extract and the content of flavonoids and tannins marginally higher in the diethyl ether extract. The antioxidant activity (DPPH of the ethanolic extract of V. minor was significantly stronger as compared to the diethyl ether extract, and the reduction potential was approximately the same.

  4. Analysis of the effectiveness of moderate levels of physical activity to reduce the risk of cardiovascular disease, A Meta-analysis

    Directory of Open Access Journals (Sweden)

    Christian Martin Garcia

    2014-12-01

    Full Text Available Objectives: a. The determination of the efficacy of physical activity in reducing the risk of cardiovascular disease; b. The Analysis of the relative changes in the levels of cardiovascular disease risk according to different intensities of physical activity (low-moderate. Methodology: The search was performed for studies with PUBMED data base. Then, the mean effect size of the studies included in the meta-analysis was calculated and Egger's test was applied to rule out any possible publication bias. Upon detection of heterogeneity, we proceeded to an analysis of the moderating variables. Results: A mean effect size of 0.762 (95% confidence interval 0678-0857 was obtained. Then The Egger test was applied which yielded a p-value of 0.67 (CI 0.95, such that the absence of publication bias was confirmed. The analysis of the moderating variables determined that the ensuing years (p = 0.000, 95% CI and the countries of study (p = 0.0096; 95% CI in part explain the heterogeneity detected. Conclusion: It can be concluded that the practice of physical activity at moderate intensities provides a protective effect on the individuals who make physical activity by reducing the risk these individuals to cardiovascular diseases.

  5. Neutron activation analysis of airborne inorganic pollutants

    International Nuclear Information System (INIS)

    Oerdoegh, M.; Kalman, L.

    1975-01-01

    The aim of the studies was to determine the radioactive and non-radioactive pollution of the air in the environment of the atomic reactor WWR-S of the Hungarian Academy of Sciences. Accordingly the investigations were carried out by two ways: the samples were analysed partly without previous irradiation and partly by neutron activation analysis. The use of several filter papers was studied and the most suitable filter paper (Whatman No. 41) was chosen for this investigation. The quantitative determination of more than twenty elements has been performed. First the natural activity of the aerosol samples taken periodically was measured and subsequently they have been analysed after irradiation in the atomic reactor for 1 minute, 1 hour, and 50 hours, respectively. A 45 cm 3 Ge/Li detector/ Nuclear Diodes/ was used in connection with a 1024 channel analyzer /type NTA-512B/. The analyses were made nondestructively, and the gamma-spectra were evaluated by computer. (K.A.)

  6. Radiometric ages of some igneous rocks from the southern and southwestern coalfields of New South Wales

    International Nuclear Information System (INIS)

    Carr, P.F.; Facer, R.A.

    1980-01-01

    Samples from six igneous rock units of the Southern and Southwestern Coalfields (Sydney Basin) of New South Wales have been dated using the K-Ar radiometric technique. The following ages were determined: a dolerite from Towradgi, 243 +- 10 MY; a dolerite from a diamond-drill hole at Sutton Forest, 202 +- 8 MY; the Bong Bong Basalt, 190 +- 8 MY; the Good Dog Lamprophyre, 101 +- 4 MY; a teschenite from South Bulli coal mine 74.0 +- 3.6 MY; and a dolerite from Robertson, 63.8 +- 3.2 MY. Combination of these new ages wth previously-published ages indicates that igneous activity in the Southern and Southwestern Coalfields occurred during four discrete periods of time - Middle-to-Late Permian; Late Triassic to Early Jurassic; mid-Cretaceous (only the Good Dog Lamprophyre has yielded such an age); and latest Cretaceous to Late Oligocene

  7. Applications of neutron activation analysis technique

    International Nuclear Information System (INIS)

    Jonah, S. A.

    2000-07-01

    The technique was developed as far back as 1936 by G. Hevesy and H. Levy for the analysis of Dy using an isotopic source. Approximately 40 elements can be analyzed by instrumental neutron activation analysis (INNA) technique with neutrons from a nuclear reactor. By applying radiochemical separation, the number of elements that can be analysed may be increased to almost 70. Compared with other analytical methods used in environmental and industrial research, NAA has some unique features. These are multi-element capability, rapidity, reproducibility of results, complementarity to other methods, freedom from analytical blank and independency of chemical state of elements. There are several types of neutron sources namely: nuclear reactors, accelerator-based and radioisotope-based sources, but nuclear reactors with high fluxes of neutrons from the fission of 235 U give the most intense irradiation, and hence the highest available sensitivities for NAA. In this paper, the applications of NAA of socio-economic importance are discussed. The benefits of using NAA and related nuclear techniques for on-line applications in industrial process control are highlighted. A brief description of the NAA set-ups at CERT is enumerated. Finally, NAA is compared with other leading analytical techniques

  8. Calcium determination in bone by proton activation analysis. Progress report

    International Nuclear Information System (INIS)

    Wilson, R.; Adelstein, S.

    1974-01-01

    The incidence of post-menopausal osteoporosis in almost epidemic proportions makes the early diagnosis and development of effective therapy a matter of considerable concern. Current status of the project is reviewed and new applications of calcium determination by in vivo proton activation analysis are discussed. The proton activation method promises to give precise and reproducible measurements of calcium content for a single vertebra or several vertebrae in vivo. By controlling the number and energy of protons incident on a vertebra and by accurately detecting the number of 2.17 MeV gamma rays emitted, one may determine the 40Ca content. The proton technique offers advantages by directly measuring calcium in a very well-defined region. On-going studies by the construction of a lead shield for in vivo counting and for the analysis of the results are also given

  9. A file of reference data for multiple-element neutron activation analysis

    International Nuclear Information System (INIS)

    Kabina, L.P.; Kondurov, I.A.; Shesterneva, I.M.

    1983-12-01

    Data needed for planning neutron activation analysis experiments and processing their results are given. The decay schemes of radioactive nuclei formed in irradiation with thermal neutrons during the (n,γ) reaction taken from the international ENSDF file are used for calculating the activities of nuclei and for drawing up an optimum table for identifying gamma lines in the spectra measured. (author)

  10. Engineering analysis activities in support of susquehanna unit 1 startup testing and cycle 1 operations

    International Nuclear Information System (INIS)

    Miller, G.D.; Kukielka, C.A.; Olson, L.M.; Refling, J.G.; Roscioli, A.J.; Somma, S.A.

    1985-01-01

    The engineering analysis group is responsible for all nuclear plant systems analysis and reactor analysis activities, excluding fuel management analysis, at Pennsylvania Power and Light Company. These activities include making pretest and posttest predictions of startup tests; analyzing unplanned or unexpected transient events; providing technical training to plant personnel; assisting in the development of emergency drill scenarios; providing engineering evaluations to support design and technical specification changes, and evaluating, assessing, and resolving a number of license conditions. Many of these activities have required the direct use of RETRAN models. Two RETRAN analyses that were completed to support plant operations - a pretest analysis of the turbine trip startup test, and a posttest analysis of the loss of startup transformer event - are investigated. For each case, RETRAN results are compared with available plant data and comparisons are drawn on the acceptability of the performance of the plant systems

  11. Determination of minor-and trace elements in magnesite samples, by activation analysis

    International Nuclear Information System (INIS)

    Sepulveda Munita, C.J.A.

    1979-01-01

    A method employing activation analysis with thermal neutron was developed for the determination of minor and trace elements in magnesite samples from the states of Ceara and Bahia (Brazil). Ten samples were analyzed. A qualitative analysis of the samples indicated the presence of Mn, Fe, Sc, Ca, Cu, Co and some of the lanthanides. The experimental part includes a non-destructive analysis of manganese and analysis with chemical separation of the other elements, individually or in groups, after sample dissolution, The dissolutions were made with concentrated HCl and the further separations were carried out in 8 N HCl medium. Iron was separated by means of an extraction of HFeCl 4 with isopropyl ether. Scandium and calcium were determined by retention of scandium with di-(2-ehylhexyl) phosphoric acid (HDEHP). The activities of 46 Sc and 47 Sc (a 47 Ca descendant) were employed for the analysis of scandium and calcium in the sample. In the effluent of the kieselguhr column copper and cobalt were determined, after retention in an anionic resin of the CuCl - 3 and CoCl - 3 complexes. Finally, in the effluent of the resin, the lanthanide group was separated by oxalate precipitation. In the gamma-ray spectrum of this precipitate the elements europium, cerium, samarium and lanthanum were determined. A detailed study of the possible interferences in the neutron activation analysis of the elements analysed was also made. The precision and accuracy of the results obtained and the sensitivity of the method are discussed. (Author) [pt

  12. Elaboration of procedure for analysis of industrial and economic activities: the experience of LUKoil petroleum company

    International Nuclear Information System (INIS)

    Ulanov, V.L.; Kirpichev, V.M.

    1996-01-01

    The research and engineering centre within LUKoil company for economic studies has elaborated a method permitting analysis of production and economic activities of the LUKOIL petroleum production complex. The method envisages the following trends of analysis: general assessment of production and economic activities, analysis of basic production assets, manpower and wages use, net cost of marketable products, the state of finances, as well as specific features in analyzing the activities undertaken by joint ventures

  13. Activation analysis of trace metals in several kinds of tissues of even-toed ungulates

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Sato, S.; Terui, S.; Mitsugashira, T.

    1999-01-01

    The normal concentration levels of trace metals in several kinds of tissues of even-toed ungulates have been determined by instrumental neutron activation analysis, photon activation analysis, and flame atomic absorption spectrometry. In the present work the concentrations of 13 elements (Ag, Br, Ca, Co, Cu, Fe, Mg, Mn, Mo, Na, Rb, Se, and Zn) were analyzed. (author)

  14. Offgas Analysis and Pyrolysis Mechanism of Activated Carbon from Bamboo Sawdust by Chemical Activation With KOH

    Institute of Scientific and Technical Information of China (English)

    TIAN Yong; LIU Ping; WANG Xiufang; ZHONG Guoying; CHEN Guanke

    2011-01-01

    Bamboo sawdust was used as the precursor for the multipurpose use of waste.Offgases released during the activation process of bamboo by KOH were investigated quantitatively and qualitatively by a gas analyzer. TG/DTG curves during the pyrolysis process with different impregnation weight ratios (KOH to bamboo) were obtained by a thermogravimetric analyzer. Pyrolysis mechanism of bamboo was proposed. The results showed that the offgases were composed of CO, NO,SO2 and hydrocarbon with the concentration of 1 372, 37, 86, 215 mg/L, respectively. Thermogravimetric analysis indicated that the pyrolytic process mainly experienced two steps. The first was the low temperature activation step (lower than 300 ℃), which was the pre-activation and induction period.The second was the high temperature activation step(higher than 550 ℃), which was a radial activation followed by pore production. The second process was the key to control the pore distribution of the final product.

  15. Mercury determination in natural waters using neutron activation analysis

    International Nuclear Information System (INIS)

    Cagnone, M.; Marques, R.O.

    1994-01-01

    Available as short communication only. An analytical method for quantitative determination of Mercury traces in river and sea water is proposed. The neutron activation method and radiochemical separation of Mercury by developing of C L 4 Hg -2 complex, and their chromatographic separation using anionic exchange resin Dowex 1 X 8 of 400 mesh is used. The quantitative determination is done by gamma spectrometric analysis. The selection limits reached with this method showed that this is an amenable procedure in routine mercury determination in the ppb level, specially useful in the environmental contamination analysis. (author). 3 refs, 2 figs, 1 tab

  16. Multielemental neutron activation analysis of some egyptian cement samples

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Abdel-Basset, N.; Soroor, A.; Hassan, A.M.

    1996-01-01

    Multielemental analysis of normal, Karnak and sea-water cement samples were performed by neutron activation analysis technique using the (ET-R R-1) reactor for sample irradiation. The Data were collected and analysed by means of the (HPGe) detection system and a Pca computer. A total of 23 elements namely, Na, A1, C 1, K, Ca, Sc, Cr, Mn, Fe, Co, Zn, Sr, Ba, La, Sm, Eu, Yb, Lu, Ta, Au, Th and U were identified and analysed with concentrations ranging from 1 ppm upto 62% a comparison between the elemental concentrations of the three cement types is given. 2 tabs

  17. Neutron activation analysis as applied to instrumental analysis of trace elements from seawater

    International Nuclear Information System (INIS)

    Boniforti, R.; Moauro, A.; Madaro, M.

    1983-01-01

    Particulate matter collected from the coastal area delimited by the mouth of the river Volturno and the Sabaudia lake has been analyzed by instrumental neutron activation analysis for its content of twenty-two trace elements. The results for surface water and bottom water are reported separately, thus evidencing the effect of sampling depth on the concentration of many elements. The necessity of accurately 'cleaning' the filters before use is stressed

  18. Survey of trace elements in coals and coal-related materials by neutron activation analysis

    International Nuclear Information System (INIS)

    Ruch, R.R.; Cahill, R.A.; Frost, J.K.; Camp, L.R.; Gluskoter, H.J.

    1977-01-01

    Utilizing primarily instrumental neutron activation analysis and other analytical methods such as neutron-activation analysis with radiochemical separation, emission spectrochemical analysis, atomic absorption spectroscopy, X-ray fluorescence analysis, ion-selective electrode analysis, and American Society for Testing of Materials procedures (ASTM), as many as 61 elements were quantitatively surveyed in 170 U.S. whole coals, 70 washed coals, and 40 bench samples. Data on areal and vertical distributions in various regions were obtained along with extensive information on the mode of occurence of various elements in the coal matrix itself. Efforts have been made to attain the maximal accuracy and precision possible for a wide variety of elements in the inhomogeneous coal matrix. (T.G.)

  19. Phosphorus Determination by Derivative Activation Analysis: A Multifaceted Radiochemical Application.

    Science.gov (United States)

    Kleppinger, E. W.; And Others

    1984-01-01

    Although determination of phosphorus is important in biology, physiology, and environmental science, traditional gravimetric and colorimetric methods are cumbersome and lack the requisite sensitivity. Therefore, a derivative activation analysis method is suggested. Background information, procedures, and results are provided. (JN)

  20. Bayesian statistics applied to neutron activation data for reactor flux spectrum analysis

    International Nuclear Information System (INIS)

    Chiesa, Davide; Previtali, Ezio; Sisti, Monica

    2014-01-01

    Highlights: • Bayesian statistics to analyze the neutron flux spectrum from activation data. • Rigorous statistical approach for accurate evaluation of the neutron flux groups. • Cross section and activation data uncertainties included for the problem solution. • Flexible methodology applied to analyze different nuclear reactor flux spectra. • The results are in good agreement with the MCNP simulations of neutron fluxes. - Abstract: In this paper, we present a statistical method, based on Bayesian statistics, to analyze the neutron flux spectrum from the activation data of different isotopes. The experimental data were acquired during a neutron activation experiment performed at the TRIGA Mark II reactor of Pavia University (Italy) in four irradiation positions characterized by different neutron spectra. In order to evaluate the neutron flux spectrum, subdivided in energy groups, a system of linear equations, containing the group effective cross sections and the activation rate data, has to be solved. However, since the system’s coefficients are experimental data affected by uncertainties, a rigorous statistical approach is fundamental for an accurate evaluation of the neutron flux groups. For this purpose, we applied the Bayesian statistical analysis, that allows to include the uncertainties of the coefficients and the a priori information about the neutron flux. A program for the analysis of Bayesian hierarchical models, based on Markov Chain Monte Carlo (MCMC) simulations, was used to define the problem statistical model and solve it. The first analysis involved the determination of the thermal, resonance-intermediate and fast flux components and the dependence of the results on the Prior distribution choice was investigated to confirm the reliability of the Bayesian analysis. After that, the main resonances of the activation cross sections were analyzed to implement multi-group models with finer energy subdivisions that would allow to determine the

  1. Multielement characterization of atmospheric pollutants by x-ray fluorescence analysis and instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rancitelli, L.A.; Tanner, T.M.

    1976-01-01

    The simultaneous measurement of a wide spectrum of elements in aerosols collected on air filters and in rainwater can yield information on the origin, transport, and removal of atmospheric pollutants. In order to determine the elemental content of these aerosols, a pair of highly sensitive, precise and complementing instrumental techniques, x-ray fluorescence and neutron activation analysis, have been developed and employed. Data are presented on the results of combined x-ray fluorescence and activation analysis of aerosols collected in a number of urban areas of the USA and from the 80th median sampling network in March 1972. From a comparison of these ratios in granite and diabase with those of filters placed in urban areas, it is evident that Zn, Se, Sb, Hg, and Pb levels have been increased by as much as several orders of magnitude. Al, Co, La, Fe, Eu, Sm, Tb, Ta, Hf, and Th appear to exist at levels compatible with an earth's crust origin

  2. Mapping brain activity in gradient-echo functional MRI using principal component analysis

    Science.gov (United States)

    Khosla, Deepak; Singh, Manbir; Don, Manuel

    1997-05-01

    The detection of sites of brain activation in functional MRI has been a topic of immense research interest and many technique shave been proposed to this end. Recently, principal component analysis (PCA) has been applied to extract the activated regions and their time course of activation. This method is based on the assumption that the activation is orthogonal to other signal variations such as brain motion, physiological oscillations and other uncorrelated noises. A distinct advantage of this method is that it does not require any knowledge of the time course of the true stimulus paradigm. This technique is well suited to EPI image sequences where the sampling rate is high enough to capture the effects of physiological oscillations. In this work, we propose and apply tow methods that are based on PCA to conventional gradient-echo images and investigate their usefulness as tools to extract reliable information on brain activation. The first method is a conventional technique where a single image sequence with alternating on and off stages is subject to a principal component analysis. The second method is a PCA-based approach called the common spatial factor analysis technique (CSF). As the name suggests, this method relies on common spatial factors between the above fMRI image sequence and a background fMRI. We have applied these methods to identify active brain ares during visual stimulation and motor tasks. The results from these methods are compared to those obtained by using the standard cross-correlation technique. We found good agreement in the areas identified as active across all three techniques. The results suggest that PCA and CSF methods have good potential in detecting the true stimulus correlated changes in the presence of other interfering signals.

  3. Applications of the photo-nuclear reaction data for activation analysis

    International Nuclear Information System (INIS)

    Odsuren, M.; Khuukhenkhuu, G.; Turbold, A.; Davaa, S.; Baatarkhuu, D.

    2015-01-01

    In the relative method of activation analysis by continuum wide spectrum gamma-rays the same isotope is usually used for standard reference element and sample material in connection with different dependence of the reaction cross sections on the irradiation beam energy. But, in practice suitable isotopes for reference element are not always available. So, in this paper, we suggest a new method for photo-activation analysis in which is used the correction factor. This factor takes into account the difference in the photo-nuclear reaction cross section dependence on the gamma-ray energy for standard reference isotope and sample elements. The correction factor is determined by three methods of experimental, theoretical and TALYS evaluation. Pure metal foils of Au, Cu and Mo were irradiated by bremsstrahlung gamma-rays on the electron cyclic accelerator Microtron MT-22 at the Nuclear Research Center, National University of Mongolia. Gamma spectra of the activated metal foils were measured by HP-Ge detector to obtain element contents in the samples. It was shown that experimental results with correction factors are satisfactorily in agreement with real values of the element contents in the samples

  4. Software for a measuring facility for activation analysis

    International Nuclear Information System (INIS)

    De Keyser, A.; De Roost, E.

    1985-01-01

    A software package has been developed for an APPLE P.C. The programs are intended to control an automated measuring station for photon activation analysis at GELINA, the linear accelerator of C.B.N.M. at Geel (Belgium). They allow to set-up a measuring scheme, to execute it under computer control, to accumulate and store 2 K-spectra using a built-in ADC and to output the results as listings, plots or evaluated reports

  5. Radiation hygiene analysis of medical activities in Norway

    International Nuclear Information System (INIS)

    Olerud, H.M.

    1987-01-01

    A computer program for the evaluation of radiation protection parameters connected to diagnostic X-ray examination has been developed. For a selected X-ray examination the program picks out key values from a data base containg patient observations and calculates integral doses, collective doses and i njury cases . When the volume of the data base is sufficient large, a total concequence analysis of diagnostric X-ray activities in Norway will be carried out

  6. Distributed activation energy model for kinetic analysis of multi-stage hydropyrolysis of coal

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.; Li, W.; Wang, N.; Li, B. [Chinese Academy of Sciences, Taiyuan (China). Inst. of Coal Chemistry

    2003-07-01

    Based on the new analysis of distributed activation energy model, a bicentral distribution model was introduced to the analysis of multi-stage hydropyrolysis of coal. The hydropyrolysis for linear temperature programming with and without holding stage were mathematically described and the corresponding kinetic expressions were achieved. Based on the kinetics, the hydropyrolysis (HyPr) and multi-stage hydropyrolysis (MHyPr) of Xundian brown coal was simulated. The results shows that both Mo catalyst and 2-stage holding can lower the apparent activation energy of hydropyrolysis and make activation energy distribution become narrow. Besides, there exists an optimum Mo loading of 0.2% for HyPy of Xundian lignite. 10 refs.

  7. THEORETICAL PRINCIPLES OF PSYCHOLOGICAL ANALYSIS OF STUDENTS’ GROUP PROJECT ACTIVITY WHILE LEARNING FOREIGN LANGUAGE

    Directory of Open Access Journals (Sweden)

    Viktoriia Kalamazh

    2016-06-01

    Full Text Available In this research the theoretical principles of psychological analysis of group project activity of students in the process of learning foreign language are defined on the basis of subject-activity, socio-psychological and cognitive paradigms. The approaches of different authors to the understanding of the concept of project and in particular group project activity are considered. The difficulties of the theoretical analysis of this specific notion are indicated due to the considerable variety of subjects, types and forms of the pedagogical activity, academic disciplines regarding which the researches are being carried out. Not disclosed aspects of organizing the group project activity of students are being determined, among them is a project group as an autonomous subject of joint activity for the realization students’ project activity while learning a foreign language; forming psychological readiness of teacher and student to use project method; the role of metacognitive aspect in the surrounding, where the project activity is being carried out; group functioning through the project work as a subject of group examination. It has been indicated that the analysis of project activity as an innovative technology must include its assessment as a condition of student’s developing as a subject of learning activity, his personal, socio-psychological, intellectual and professional self-perfection. Three levels of subjectivity in group project activity are being distinguished: teacher; each particular student; and student project group. Interaction between teacher and student is based on subject-subject relations. An organization of a project activity while learning a foreign language is considered as the one in which the student is moving in order to get the manager position and to master the basis of expert knowledge. Hereby, the main stress is on the group role as a subject of group examination, and also on metacognitive character of the

  8. Automating the Analysis of Problem-solving Activities in Learning Environments: the Co-Lab Case Study

    NARCIS (Netherlands)

    Duque, R.; Bollen, Lars; Anjewierden, Anjo Allert; Bravo, C.

    2012-01-01

    The analysis of problem-solving activities carried out by students in learning settings involves studying the students' actions and assessing the solutions they have created. This analysis constitutes an ideal starting point to support an automatic intervention in the student activity by means of

  9. Analysis of essential oils from Voacanga africana seeds at different hydrodistillation extraction stages: chemical composition, antioxidant activity and antimicrobial activity.

    Science.gov (United States)

    Liu, Xiong; Yang, Dongliang; Liu, Jiajia; Ren, Na

    2015-01-01

    In this study, essential oils from Voacanga africana seeds at different extraction stages were investigated. In the chemical composition analysis, 27 compounds representing 86.69-95.03% of the total essential oils were identified and quantified. The main constituents in essential oils were terpenoids, alcohols and fatty acids accounting for 15.03-24.36%, 21.57-34.43% and 33.06-57.37%, respectively. Moreover, the analysis also revealed that essential oils from different extraction stages possessed different chemical compositions. In the antioxidant evaluation, all analysed oils showed similar antioxidant behaviours, and the concentrations of essential oils providing 50% inhibition of DPPH-scavenging activity (IC50) were about 25 mg/mL. In the antimicrobial experiments, essential oils from different extraction stages exhibited different antimicrobial activities. The antimicrobial activity of oils was affected by extraction stages. By controlling extraction stages, it is promising to obtain essential oils with desired antimicrobial activities.

  10. Multilevel predictors of adolescent physical activity: a longitudinal analysis

    Directory of Open Access Journals (Sweden)

    Hearst Mary O

    2012-02-01

    Full Text Available Abstract Background To examine how factors from a social ecologic model predict physical activity (PA among adolescents using a longitudinal analysis. Methods Participants in this longitudinal study were adolescents (ages 10-16 at baseline and one parent enrolled in the Transdisciplinary Research on Energetics and Cancer-Identifying Determinants of Eating and Activity (TREC-IDEA and the Etiology of Childhood Obesity (ECHO. Both studies were designed to assess a socio-ecologic model of adolescent obesity risk. PA was collected using ActiGraph activity monitors at two time points 24 months apart. Other measures included objective height and weight, adolescent and parent questionnaires on multilevel psychological, behavioral and social determinants of PA, and a home PA equipment inventory. Analysis was conducted using SAS, including descriptive characteristics, bivariate and stepped multivariate mixed models, using baseline adjustment. Models were stratified by gender. Results There were 578 adolescents with complete data. Results suggest few statistically significant longitudinal associations with physical activity measured as minutes of MVPA or total counts from accelerometers. For boys, greater self-efficacy (B = 0.75, p = 0.01 and baseline MVPA (B = 0.55, p p = 0.01 and barriers (B = -0.32, p = 0.05 significantly predicted MVPA at follow-up in the full model. The full multilevel model explained 30% of the variance in PA among boys and 24% among girls. Conclusions PA change in adolescents is a complex issue that is not easily understood. Our findings suggest early PA habits are the most important predictor of PA levels in adolescence. Intervention may be necessary prior to middle school to maintain PA through adolescence.

  11. Determination of gold in some Myanmar indigenous medicines by neutron activation analysis

    International Nuclear Information System (INIS)

    Myint U.; Sein Sein Yi

    1995-01-01

    Gold has been determined in two Myanmar indigenous medicines TMF 14 (Devaauthada), TMF 15 (Shwe Thwe Say) by neutron activation analysis using an Am(Be) radionuclide neutron source. The activity of 411 keV of the 198 Au has been measured. (author). 2 refs., 1 fig., 1 tab

  12. Multi-element analysis of emeralds and associated rocks by k{sub 0} neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Acharya, R.N.; Mondal, R.K.; Burte, P.P.; Nair, A.G.C.; Reddy, N.B.Y.; Reddy, L.K.; Reddy, A.V.R.; Manohar, S.B

    2000-12-15

    Multi-element analysis was carried out in natural emeralds, their associated rocks and one sample of beryl obtained from Rajasthan, India. The concentrations of 21 elements were assayed by Instrumental Neutron Activation Analysis using the k{sub 0} method (k{sub 0} INAA method) and high-resolution gamma ray spectrometry. The data reveal the segregation of some elements from associated (trapped and host) rocks to the mineral beryl forming the gemstones. A reference rock standard of the US Geological Survey (USGS BCR-1) was also analysed as a control of the method.

  13. The technical analysis of the stock exchange and physics: Japanese candlesticks for solar activity

    Science.gov (United States)

    Dineva, C.; Atanasov, V.

    2013-09-01

    In this article, we use the Japanese candlesticks, a method popular in the technical analysis of the Stock/Forex markets and apply it to a variable in physics-the solar activity. This method is invented and used exclusively for economic analysis and its application to a physical problem produced unexpected results. We found that the Japanese candlesticks are convenient tool in the analysis of the variables in the physics of the Sun. Based on our observations, we differentiated a new cycle in the solar activity.

  14. Activities of the Laboratory of Neutron Activation Analysis in the Radiochemistry Division - IPEN/CNEN/SP/Brazil

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.

    1988-01-01

    Neutron activation analysis (NAA) is one of the relevant applications of nuclear research reactors. Due to the high neutron fluxes available in these reactors, an excellent sensitivity of analysis is attained for many elements. NAA is one of the most sensitive, precise and accurate analytical methods for trace element determination. NAA has been one of the main activities of the Radiochemistry Division of IPEN, since the befinning of the operation of the nuclear reactor IEA-R1. Most of the effort was devoted to research work, aimed to improvements in the method as well as to its applications to several kinds of matrixes (geological, biological, metallic, environmental, forensic). Besides, analytical services were also offered, to the CNEN, to industries, universities, mining companies and research institutes. In the present paper, a review is made of the research work being developed presently at the Radiochemistry Division of IPEN. A discussion is also made of the planned expansion of the analytical services offered. (author) [pt

  15. Physical activity and stroke: a meta-analysis of observational data

    NARCIS (Netherlands)

    Wendel-Vos, G.C.W.; Schuit, A.J.; Feskens, E.J.M.; Boshuizen, H.C.; Verschuren, W.M.M.; Saris, W.H.M.; Kromhout, D.

    2004-01-01

    Background Based on studies published so far, the protective effect of physical activity on stroke remains controversial. Specifically, there is a lack of insight into the sources of heterogeneity between studies. Methods Meta-analysis of observational studies was used to quantify the relationship

  16. Longitudinal Physical Activity Patterns Among Older Adults: A Latent Transition Analysis.

    Science.gov (United States)

    Mooney, Stephen J; Joshi, Spruha; Cerdá, Magdalena; Kennedy, Gary J; Beard, John R; Rundle, Andrew G

    2018-05-14

    Most epidemiologic studies of physical activity measure either total energy expenditure or engagement in a single activity type, such as walking. These approaches may gloss over important nuances in activity patterns. We performed a latent transition analysis to identify patterns of activity types as well as neighborhood and individual determinants of changes in those activity patterns over two years in a cohort of 2,023 older adult residents of New York City, NY, surveyed between 2011 and 2013. We identified seven latent classes: 1) Mostly Inactive, 2) Walking, 3) Exercise, 4) Household Activities and Walking, 5) Household Activities and Exercise, 6) Gardening and Household Activities, and 7) Gardening, Household Activities, and Exercise. The majority of subjects retained the same activity patterns between waves (54% unchanged between waves 1 and 2, 66% unchanged between waves 2 and 3).Most latent class transitions were between classes distinguished only by one form of activity, and only neighborhood unemployment was consistently associated with changing between activity latent classes. Future latent transition analyses of physical activity would benefit from larger cohorts and longer follow-up periods to assess predictors of and long-term impacts of changes in activity patterns.

  17. Phytochemical Analysis, Antioxidant Activity, Fatty Acids Composition, and Functional Group Analysis of Heliotropium bacciferum

    Directory of Open Access Journals (Sweden)

    Sohail Ahmad

    2014-01-01

    Full Text Available Heliotropium bacciferum is paramount in medicinal perspective and belongs to Boraginaceae family. The crude and numerous fractions of leaves, stem, and roots of the plant were investigated for phytochemical analysis and DPPH radical scavenging activity. Phytochemical analysis of crude and fractions of the plant revealed the presence of alkaloids, saponins, tannins, steroids, terpenoids, flavonoids, glycosides, and phenols. The antioxidant (free radical scavenging activity of various extracts of the Heliotropium bacciferum was resolute against 2,2-diphenyl-1-picrylhydrazyl (DPPH radical with the avail of UV spectrophotometer at 517 nm. The stock solution (1000 mg/mL and then several dilutions (50, 100, 150, 200, and 250 mg/mL of the crude and fractions were prepared. Ascorbic acid was used as a standard. The plant leaves (52.59 ± 0.84 to 90.74 ± 1.00, stem (50.19 ± 0.92 to 89.42 ± 1.10, and roots extracts (49.19 ± 0.52 to 90.01 ± 1.02 divulged magnificent antioxidant activities. For the ascertainment of the fatty acid constituents a gas chromatograph hyphenated to mass spectrometer was used. The essential fatty acids for growth maintenance such as linoleic acid (65.70%, eicosadienoic acid (15.12%, oleic acid (8.72%, and palmitic acid (8.14% were found in high percentage. The infrared spectra of all extracts of the plant were recorded by IR Prestige-21 FTIR model.

  18. Phytochemical analysis, antioxidant activity, fatty acids composition, and functional group analysis of Heliotropium bacciferum.

    Science.gov (United States)

    Ahmad, Sohail; Ahmad, Shabir; Bibi, Ahtaram; Ishaq, Muhammad Saqib; Afridi, Muhammad Siddique; Kanwal, Farina; Zakir, Muhammad; Fatima, Farid

    2014-01-01

    Heliotropium bacciferum is paramount in medicinal perspective and belongs to Boraginaceae family. The crude and numerous fractions of leaves, stem, and roots of the plant were investigated for phytochemical analysis and DPPH radical scavenging activity. Phytochemical analysis of crude and fractions of the plant revealed the presence of alkaloids, saponins, tannins, steroids, terpenoids, flavonoids, glycosides, and phenols. The antioxidant (free radical scavenging) activity of various extracts of the Heliotropium bacciferum was resolute against 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical with the avail of UV spectrophotometer at 517 nm. The stock solution (1000 mg/mL) and then several dilutions (50, 100, 150, 200, and 250 mg/mL) of the crude and fractions were prepared. Ascorbic acid was used as a standard. The plant leaves (52.59 ± 0.84 to 90.74 ± 1.00), stem (50.19 ± 0.92 to 89.42 ± 1.10), and roots extracts (49.19 ± 0.52 to 90.01 ± 1.02) divulged magnificent antioxidant activities. For the ascertainment of the fatty acid constituents a gas chromatograph hyphenated to mass spectrometer was used. The essential fatty acids for growth maintenance such as linoleic acid (65.70%), eicosadienoic acid (15.12%), oleic acid (8.72%), and palmitic acid (8.14%) were found in high percentage. The infrared spectra of all extracts of the plant were recorded by IR Prestige-21 FTIR model.

  19. Automated analysis of prerecorded evoked electromyographic activity from rat muscle.

    Science.gov (United States)

    Basarab-Horwath, I; Dewhurst, D G; Dixon, R; Meehan, A S; Odusanya, S

    1989-03-01

    An automated microprocessor-based data acquisition and analysis system has been developed specifically to quantify electromyographic (EMG) activity induced by the convulsant agent catechol in the anaesthetized rat. The stimulus and EMG response are recorded on magnetic tape. On playback, the stimulus triggers a digital oscilloscope and, via interface circuitry, a BBC B microcomputer. The myoelectric activity is digitized by the oscilloscope before being transferred under computer control via a RS232 link to the microcomputer. This system overcomes the problems of dealing with signals of variable latency and allows quantification of latency, amplitude, area and frequency of occurrence of specific components within the signal. The captured data can be used to generate either signal or superimposed high resolution graphic reproductions of the original waveforms. Although this system has been designed for a specific application, it could easily be modified to allow analysis of any complex waveform.

  20. Neutron activation analysis using Excel files and Canberra Genie-2000

    International Nuclear Information System (INIS)

    Landsberger, S.; Jackman, K.; Welch, L.

    2005-01-01

    A method for analyzing neutron activated sample data by using Microsoft Excel as the analysis engine has been developed. A simple technique for inputting data is based on report files generated by Canberra's Genie-2000 spectroscopy system but could be easily modified to support other vendors having report formats with consistent text placement. A batch program handles operating an automatic sample changer, acquiring the data, and analyzing the spectrum to create a report of the peak locations and net area. The entire report is then transferred to within an Excel spreadsheet as the source data for neutron activation analysis. Unique Excel templates have been designed, for example, to accommodate short-lived and long-lived isotopes. This process provides a largely integrated solution to NAA while providing the results in an industry standard spreadsheet format. This software is ideally suited for teaching and training purposes. (author)