WorldWideScience

Sample records for actigait implanted drop-foot

  1. Phase II trial to evaluate the ActiGait implanted drop-foot stimulator in established hemiplegia

    DEFF Research Database (Denmark)

    Burridge, Jane H; Haugland, Morten; Pickering, Ruth M

    2007-01-01

    OBJECTIVE: To evaluate a selective implantable drop foot stimulator (ActiGait) in terms of effect on walking and safety. DESIGN: A phase II trial in which a consecutive sample of participants acted as their own controls. SUBJECTS: People who had suffered a stroke at least 6 months prior to recrui......OBJECTIVE: To evaluate a selective implantable drop foot stimulator (ActiGait) in terms of effect on walking and safety. DESIGN: A phase II trial in which a consecutive sample of participants acted as their own controls. SUBJECTS: People who had suffered a stroke at least 6 months prior...... to recruitment and had a drop-foot that affected walking were recruited from 3 rehabilitation centres in Denmark. METHODS: Stimulators were implanted into all participants. Outcome measures were range of ankle dorsiflexion with stimulation and maximum walking speed and distance walked in 4 minutes. Measurements...

  2. Patients' perceptions of the benefits and problems of using the ActiGait implanted drop-foot stimulator

    DEFF Research Database (Denmark)

    Burridge, Jane H; Haugland, Morten; Larsen, Birgit

    2008-01-01

    OBJECTIVE: To evaluate patients' perceptions of the benefits and problems associated with using the ActiGait implanted drop-foot stimulator. METHOD: Thirteen participants who had suffered a stroke at least 6 months prior to recruitment, had a drop-foot that affected walking and had taken part in ...

  3. Restoration of ankle movements with the ActiGait implantable drop foot stimulator: a safe and reliable treatment option for permanent central leg palsy.

    Science.gov (United States)

    Martin, Klaus Daniel; Polanski, Witold Henryk; Schulz, Anne-Kathrin; Jöbges, Michael; Hoff, Hansjoerg; Schackert, Gabriele; Pinzer, Thomas; Sobottka, Stephan B

    2016-01-01

    OBJECT The ActiGait drop foot stimulator is a promising technique for restoration of lost ankle function by an implantable hybrid stimulation system. It allows ankle dorsiflexion by active peroneal nerve stimulation during the swing phase of gait. In this paper the authors report the outcome of the first prospective study on a large number of patients with stroke-related drop foot. METHODS Twenty-seven patients who experienced a stroke and with persisting spastic leg paresis received an implantable ActiGait drop foot stimulator for restoration of ankle movement after successful surface test stimulation. After 3 to 5 weeks, the stimulator was activated, and gait speed, gait endurance, and activation time of the system were evaluated and compared with preoperative gait tests. In addition, patient satisfaction was assessed using a questionnaire. RESULTS Postoperative gait speed significantly improved from 33.9 seconds per 20 meters to 17.9 seconds per 20 meters (p < 0.0001), gait endurance from 196 meters in 6 minutes to 401 meters in 6 minutes (p < 0.0001), and activation time from 20.5 seconds to 10.6 seconds on average (p < 0.0001). In 2 patients with nerve injury, surgical repositioning of the electrode cuff became necessary. One patient showed a delayed wound healing, and in another patient the system had to be removed because of a wound infection. Marked improvement in mobility, social participation, and quality of life was confirmed by 89% to 96% of patients. CONCLUSIONS The ActiGait implantable drop foot stimulator improves gait speed, endurance, and quality of life in patients with stroke-related drop foot. Regarding gait speed, the ActiGait system appears to be advantageous compared with foot orthosis or surface stimulation devices. Randomized trials with more patients and longer observation periods are needed to prove the long-term benefit of this device.

  4. Thyrotoxicosis Presenting as Unilateral Drop Foot.

    Science.gov (United States)

    Hara, Kenju; Miyata, Hajime; Motegi, Takahide; Shibano, Ken; Ishiguro, Hideaki

    2017-01-01

    Neuromuscular disorders associated with hyperthyroidism have several variations in their clinical phenotype, such as ophthalmopathy, periodic paralysis, and thyrotoxic myopathy. We herein report an unusual case of thyrotoxic myopathy presenting as unilateral drop foot. Histopathological examinations of the left tibialis anterior muscle showed marked variation in the fiber size, mild inflammatory cell infiltration, and necrotic and regenerated muscle fibers with predominantly type 1 fiber atrophy. Medical treatment with propylthiouracil resulted in complete improvement of the left drop foot. This case expands the phenotype of thyrotoxicosis and suggests that thyrotoxicosis be considered as a possible cause of unilateral drop foot.

  5. Patient Satisfaction of Using the ActiGait® Drop Foot Stimulator System and Effect of Treatment on Walking

    DEFF Research Database (Denmark)

    Severinsen, Kåre Eg; Grey, Kurt; Juhl, Anne

    2014-01-01

    In this case-control study of ten chronic stroke patients with drop foot we report preliminary data on patient satisfaction, self- assessed changes in walking performance, effect on walking speed as well as adverse effects after surgical implantation of the ActiGait® drop foot stimulator in a cli...... with great care due to the small population size, the case control design and the limitations of the ten meter walk test in describing walking quality and safety....

  6. Custom-Made Foot Orthoses Decrease Medial Foot Loading During Drop Jump in Individuals With Patellofemoral Pain

    DEFF Research Database (Denmark)

    Rathleff, Michael S; Richter, Camilla; Brushøj, Christoffer

    2016-01-01

    OBJECTIVE: To investigate the effect of foot orthoses on medial-to-lateral plantar forces during drop jump and single leg squat, and second, to explore the self-reported change in symptoms after 12 weeks of wearing the orthoses in individuals with patellofemoral pain (PFP). DESIGN: Cohort study...... with 12 weeks of follow-up. SETTING: Hospital setting. PARTICIPANTS: 23 adults with PFP. INTERVENTIONS: Custom-made foot orthoses. MAIN OUTCOME MEASURES: Foot loading (plantar pressure) was collected from the most painful side during drop jump and single leg squat using pressure sensitive Pedar insoles....... Primary outcome was the medial-to-lateral peak force under the forefoot during drop jump. The PFP syndrome severity score was used to measure self-reported improvement from baseline to follow-up. RESULTS: Orthoses were associated with a significant 2.9%-point (95% confidence intervals: 0.7-5.1) reduction...

  7. Conversion Disorder; an Unusual Etiology of Unilateral Foot Drop.

    Science.gov (United States)

    Ayaz, Saeed Bin; Matee, Sumeera; Malik, Riffat; Ahmad, Khalil

    2015-06-01

    Foot drop is generally a consequence of common peroneal or sciatic nerve injury or L5 radiculopathy but rarely, it can be a manifestation of conversion disorder. A 24-year-old male presented with a foot drop on left side that developed overnight. He had difficulty walking with a trunk tilt towards right side and numbness in left leg up to mid-thigh. The initial diagnosis by the general practitioner was common peroneal nerve injury, which was not supported by the subsequent detailed examination in the physiatry department. Routine laboratory investigations, computed tomographic scan of brain and electrophysiological evaluation were normal. In a multidisciplinary team evaluation involving a psychiatrist, he was diagnosed to be suffering from conversion disorder and was advised gait retraining, cognitive and behavioral therapy and tablet venlafaxine. By sixth day of treatment, the patient was able to walk independently with a normal gait pattern and reported complete recovery of his symptoms. In the absence of an identifiable organic cause of foot drop in a patient, conversion disorder may be considered necessitating early intervention by a psychiatrist.

  8. A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop

    Directory of Open Access Journals (Sweden)

    Chin Robin

    2009-06-01

    Full Text Available Abstract Background A self-contained, self-controlled, pneumatic power harvesting ankle-foot orthosis (PhAFO to manage foot-drop was developed and tested. Foot-drop is due to a disruption of the motor control pathway and may occur in numerous pathologies such as stroke, spinal cord injury, multiple sclerosis, and cerebral palsy. The objectives for the prototype PhAFO are to provide toe clearance during swing, permit free ankle motion during stance, and harvest the needed power with an underfoot bellow pump pressurized during the stance phase of walking. Methods The PhAFO was constructed from a two-part (tibia and foot carbon composite structure with an articulating ankle joint. Ankle motion control was accomplished through a cam-follower locking mechanism actuated via a pneumatic circuit connected to the bellow pump and embedded in the foam sole. Biomechanical performance of the prototype orthosis was assessed during multiple trials of treadmill walking of an able-bodied control subject (n = 1. Motion capture and pressure measurements were used to investigate the effect of the PhAFO on lower limb joint behavior and the capacity of the bellow pump to repeatedly generate the required pneumatic pressure for toe clearance. Results Toe clearance during swing was successfully achieved during all trials; average clearance 44 ± 5 mm. Free ankle motion was observed during stance and plantarflexion was blocked during swing. In addition, the bellow component repeatedly generated an average of 169 kPa per step of pressure during ten minutes of walking. Conclusion This study demonstrated that fluid power could be harvested with a pneumatic circuit built into an AFO, and used to operate an actuated cam-lock mechanism that controls ankle-foot motion at specific periods of the gait cycle.

  9. Foot Drop: Looking Beyond Common Peroneal Nerve Palsy – A Neurophysiology Centre Experience

    LENUS (Irish Health Repository)

    Yap, SM

    2016-04-01

    Foot drop is a complex symptom with a considerable range in aetiology, severity and prognosis. We aim to characterise the aetiologies of foot drop and assess the diagnostic contribution of neurophysiologic testing (NCS\\/EMG). Retrospective review of consecutive referrals of foot drop to the Neurophysiology Department in Cork University Hospital was performed over a two year period (January 2012 to December 2013). Of a total of 59 referrals, common peroneal nerve (CPN) palsy comprised only slightly more than half of cases; 3(5%) have central origin; 3(5%) have motor neuron disease. Six (10%) have diabetes; 7(12%) have cancer; 5(8%) were bilateral. NCS\\/EMG altered initial working diagnosis in 14 out of 52 (27%) cases whereby initial diagnosis was provided. However one-third of all cases revealed additional coexistent pathology in an anatomic location remote to that of the primary diagnosis. Foot drop with central and proximal localisations are important and under recognised. NCS\\/EMG is valuable and also reveals additional pathology which warrants investigation

  10. Bipedal gait model for precise gait recognition and optimal triggering in foot drop stimulator: a proof of concept.

    Science.gov (United States)

    Shaikh, Muhammad Faraz; Salcic, Zoran; Wang, Kevin I-Kai; Hu, Aiguo Patrick

    2018-03-10

    Electrical stimulators are often prescribed to correct foot drop walking. However, commercial foot drop stimulators trigger inappropriately under certain non-gait scenarios. Past researches addressed this limitation by defining stimulation control based on automaton of a gait cycle executed by foot drop of affected limb/foot only. Since gait is a collaborative activity of both feet, this research highlights the role of normal foot for robust gait detection and stimulation triggering. A novel bipedal gait model is proposed where gait cycle is realized as an automaton based on concurrent gait sub-phases (states) from each foot. The input for state transition is fused information from feet-worn pressure and inertial sensors. Thereafter, a bipedal gait model-based stimulation control algorithm is developed. As a feasibility study, bipedal gait model and stimulation control are evaluated in real-time simulation manner on normal and simulated foot drop gait measurements from 16 able-bodied participants with three speed variations, under inappropriate triggering scenarios and with foot drop rehabilitation exercises. Also, the stimulation control employed in commercial foot drop stimulators and single foot gait-based foot drop stimulators are compared alongside. Gait detection accuracy (98.9%) and precise triggering under all investigations prove bipedal gait model reliability. This infers that gait detection leveraging bipedal periodicity is a promising strategy to rectify prevalent stimulation triggering deficiencies in commercial foot drop stimulators. Graphical abstract Bipedal information-based gait recognition and stimulation triggering.

  11. Can orthoses and navicular drop affect foot motion patterns during running?

    Science.gov (United States)

    Eslami, Mansour; Ferber, Reed

    2013-07-01

    The purpose of this study was to examine the influence of semi-rigid foot orthoses on forefoot-rearfoot joint coupling patterns in individuals with different navicular drop measures during heel-toe running. Ten trials were collected from twenty-three male subjects who ran slowly shod at 170 steps per minute (2.23m/s) with a semi-rigid orthoses and without. Forefoot-rearfoot coupling motions were assessed using a vector coding technique during four intervals across the first 50% of stance. Subjects were divided into two groups based on navicular drop measures. A three way ANOVA was performed to examine the interaction and main effects of stance interval, orthoses condition and navicular drop (pForefoot-rearfoot coupling motion in the no-orthoses condition increased from heel-strike to foot-flat phase at a rate faster than the orthoses condition (p=0.02). Foot orthoses significantly decrease the forefoot-rearfoot joint coupling angle by reducing forefoot frontal plane motion relative to the rearfoot. Navicular drop measures did not influence joint coupling relationships between the forefoot and rearfoot during the first 50% of stance regardless of orthotic condition. Copyright © 2012 Sports Medicine Australia. All rights reserved.

  12. A pelvic motion driven electrical stimulator for drop-foot treatment.

    Science.gov (United States)

    Chen, Shih-Wei; Chen, Shih-Ching; Chen, Chiun-Fan; Lai, Jin-Shin; Kuo, Te-Son

    2009-01-01

    Foot switches operating with force sensitive resistors placed in the shoe sole were considered as an effective way for driving FES assisted walking systems in gait restoration. However, the reliability and durability of the foot switches run down after a certain number of steps. As an alternative for foot switches, a simple, portable, and easy to handle motion driven electrical stimulator (ES) is provided for drop foot treatment. The device is equipped with a single tri-axis accelerometer worn on the pelvis, a commercial dual channel electrical stimulator, and a controller unit. By monitoring the pelvic rotation and acceleration during a walking cycle, the events including heel strike and toe off of each step is thereby predicted by a post-processing neural network model.

  13. Clinical assessment of dynamic coefficient of friction effects in shoe-sole trituration of patients with drop foot.

    Science.gov (United States)

    Nima, Jamshidi; Firooz, Salami

    2012-06-01

    The aim of this study was examining the effect of human factors such as plantar friction, contact period time, and impulse on shoe-sole trituration of drop foot patients. Twenty-five patients with drop foot and twenty normal subjects were recruited in the study. The force plate and its related software's recorded human factor (coefficient of friction, ground reaction force, time of stance phase) as time dependent parameters. Dynamic coefficient of friction patterns were categorized based on their magnitude versus time when the longitudinal axis of the sole was plotted as the Y-axis and the transverse axis of the sole as X-axis during stance phase. The result of this research indicated that the average coefficient of friction among drop foot patients is 77.53 % (p value <0.05) lower than the normal subjects. Also the time of stance phase among drop foot patients is 7.56 % (p value <0.05) greater than normal subjects. There is no difference in the peaks, of vertical ground reaction force between normal and control group. The findings of this research revealed that the time of stance phase has a key role in shoe-sole trituration of patients with drop foot.

  14. Preoperative motor strength and time to surgery are the most important predictors of improvement in foot drop due to degenerative lumbar disease.

    Science.gov (United States)

    Macki, Mohamed; Syeda, Sbaa; Kerezoudis, Panagiotis; Gokaslan, Ziya L; Bydon, Ali; Bydon, Mohamad

    2016-02-15

    Palsy of dorsiflexion, or foot drop, may be due to degenerative lumbar disease and amenable to posterior spinal decompression. The objective of this study is to measure prognostic factors of and time to foot drop improvement after posterior lumbar decompression. We retrospectively reviewed 71 patients undergoing first-time, posterior lumbar decompression for foot drop due to degenerative spinal disease. Patient sex, age, comorbidities (Charlson Comorbidity Index), preoperative anterior tibialis strength (manual muscle testing, MMT), and duration of foot drop were ascertained from clinical notes. Prognostic factors affecting foot drop improvement were calculated with a discrete time proportional hazards model, in which follow-up times and outcome measures were binned into six time intervals: 1 week, 6 weeks, 3 months, 6 months, 1 year, and ≥ 1 year. Of the 71 patients, the mean age was 54.6 ± 16.0 years, and 66.2% (n=47) were males. The mean Charlson Comorbidity Index was 2.42. During a mean follow-up of 30.4 months, dorsiflexion function improved postoperatively in 73.2% (n=52) of patients. The median time to surgery from onset of foot drop was within 6 weeks, and the median preoperative MMT strength of patients with foot drop improvement was 3. Following a discrete-time proportional hazards model, duration of anterior tibialis palsy (HR=0.67, P=0.004) and preoperative muscle strength (HR=1.10, P=0.010) were significant predictors of foot drop improvement. Following an adjusted Kaplan-Meier analysis, the median time to foot drop improvement was within 6 weeks of surgical intervention. Preoperative muscle strength and palsy duration were statistically significant predictors of foot drop improvement. Furthermore, the median time to improvement was 6 weeks. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Acute unilateral foot drop as a result of direct blunt trauma to the ...

    African Journals Online (AJOL)

    This is a case report of an acute unilateral foot drop which occurred during a professional mixed martial arts (MMA) contest, specifically as a result of direct blunt trauma to the left peroneal nerve, without an accompanying fracture of the fibula. Keywords: foot extensor weakness, gait abnormality, contact sports, mixed martial ...

  16. Development of an Active Ankle Foot Orthosis to Prevent Foot Drop and Toe Drag in Hemiplegic Patients: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Jungyoon Kim

    2011-01-01

    Full Text Available We developed an active ankle-foot orthosis (AAFO that controls dorsiflexion/plantarflexion of the ankle joint to prevent foot drop and toe drag during hemiplegic walking. To prevent foot slap after initial contact, the ankle joint must remain active to minimize forefoot collision against the ground. During late stance, the ankle joint must also remain active to provide toe clearance and to aid with push-off. We implemented a series elastic actuator in our AAFO to induce ankle dorsiflexion/plantarflexion. The activator was controlled by signals from force sensing register (FSR sensors that detected gait events. Three dimensional gait analyses were performed for three hemiplegic patients under three different gait conditions: gait without AFO (NAFO, gait with a conventional hinged AFO that did not control the ankle joint (HAFO, and gait with the newly-developed AFO (AAFO. Our results demonstrate that our newly-developed AAFO not only prevents foot drop by inducing plantarflexion during loading response, but also prevents toe drag by facilitating plantarflexion during pre-swing and dorsiflexion during swing phase, leading to improvement in most temporal-spatial parameters. However, only three hemiplegic patients were included in this gait analysis. Studies including more subjects will be required to evaluate the functionality of our newly developed AAFO.

  17. Determination of normal values for navicular drop during walking: a new model correcting for foot length and gender

    DEFF Research Database (Denmark)

    Nielsen, Rasmus G; Rathleff, Michael S; Simonsen, Ole H

    2009-01-01

    participants. Normal values have not yet been established as foot length, age, gender, and Body Mass Index (BMI) may influence the navicular drop. The purpose of the study was to investigate the influence of foot length, age, gender, and BMI on the navicular drop during walking. METHODS: Navicular drop...... was measured with a novel technique (Video Sequence Analysis, VSA) using 2D video. Flat reflective markers were placed on the medial side of the calcaneus, the navicular tuberosity, and the head of the first metatarsal bone. The navicular drop was calculated as the perpendicular distance between the marker...... on the navicular tuberosity and the line between the markers on calcaneus and first metatarsal head. The distance between the floor and the line in standing position between the markers on calcaneus and first metatarsal were added afterwards. RESULTS: 280 randomly selected participants without any foot problems...

  18. An Unusual Presentation of Right-Sided Sciatica with Foot Drop.

    Science.gov (United States)

    McCabe, Fergus J; McCabe, John P

    2016-01-01

    Rarely, sciatica is of extraspinal aetiology. By compressing the sciatic nerve, swelling of the short external rotators of the hip can cause sciatica. Uncommon anatomical relationships between the sciatic nerve and local muscles may potentiate this compressive effect. In this report, we describe the presentation of right sciatica and foot drop resulting from both extreme local constriction and unusual anatomical variation of the right sciatic nerve.

  19. Feasibility of using Lokomat combined with functional electrical stimulation for the rehabilitation of foot drop

    Directory of Open Access Journals (Sweden)

    Christian B. Laursen

    2016-08-01

    Full Text Available This study investigated the clinical feasibility of combining the electromechanical gait trainer Lokomat with functional electrical therapy (LokoFET, stimulating the common peroneal nerve during the swing phase of the gait cycle to correct foot drop as an integrated part of gait therapy. Five patients with different acquired brain injuries trained with LokoFET 2-3 times a week for 3-4 weeks. Pre- and post-intervention evaluations were performed to quantify neurophysiological changes related to the patients’ foot drop impairment during the swing phase of the gait cycle. A semi-structured interview was used to investigate the therapists’ acceptance of LokoFET in clinical practice. The patients showed a significant increase in the level of activation of the tibialis anterior muscle and the maximal dorsiflexion during the swing phase, when comparing the pre- and post-intervention evaluations. This showed an improvement of function related to the foot drop impairment. The interview revealed that the therapists perceived the combined system as a useful tool in the rehabilitation of gait. However, lack of muscle selectivity relating to the FES element of LokoFET was assessed to be critical for acceptance in clinical practice.

  20. Feasibility of Using Lokomat Combined with Functional Electrical Stimulation for the Rehabilitation of Foot Drop.

    Science.gov (United States)

    Laursen, Christian B; Nielsen, Jørgen F; Andersen, Ole K; Spaich, Erika G

    2016-06-13

    This study investigated the clinical feasibility of combining the electromechanical gait trainer Lokomat with functional electrical therapy (LokoFET), stimulating the common peroneal nerve during the swing phase of the gait cycle to correct foot drop as an integrated part of gait therapy. Five patients with different acquired brain injuries trained with LokoFET 2-3 times a week for 3-4 weeks. Pre- and post-intervention evaluations were performed to quantify neurophysiological changes related to the patients' foot drop impairment during the swing phase of the gait cycle. A semi-structured interview was used to investigate the therapists' acceptance of LokoFET in clinical practice. The patients showed a significant increase in the level of activation of the tibialis anterior muscle and the maximal dorsiflexion during the swing phase, when comparing the pre- and post-intervention evaluations. This showed an improvement of function related to the foot drop impairment. The interview revealed that the therapists perceived the combined system as a useful tool in the rehabilitation of gait. However, lack of muscle selectivity relating to the FES element of LokoFET was assessed to be critical for acceptance in clinical practice.

  1. A programmable and portable NMES device for drop foot correction and blood flow assist applications.

    Science.gov (United States)

    Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; Olaighin, Gearóid

    2009-04-01

    The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor-based foot switches and MEMS-based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.

  2. Clinical assessment of diclofenac sodium eye drops in toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yan Luo

    2013-05-01

    Full Text Available AIM:To evaluate the application of diclofenac sodium eye drops in toric intraocular lens implantation. METHODS: From January 2011 to February 2012, 38 eyes of 37 patients, who underwent toric intraocular lens implantation in this hospital, were randomly divided into diclofenac sodium eye drops group(trial groupand control group. Patient's degree of cooperation during surgery and inflammation postoperation after 1 day, 3,7, days, 1 month and 3 months were evaluated. RESULTS: Patient's degree of cooperation during surgery in the trial group(1.53±0.62was significantly better than in the control group(2.40±0.88, P<0.05. Inflammation reaction was gentle in the trial group 1 day postoperatively. CONCLUSION: Diclofenac sodium eye drops used during toric intraocular lens implantation can obviously alleviate eye irritation, and increase the cooperation of patients.

  3. Hereditary Neuropathy with Liability to Pressure Palsy: A Recurrent and Bilateral Foot Drop Case Report

    Directory of Open Access Journals (Sweden)

    Filipa Flor-de-Lima

    2013-01-01

    Full Text Available Hereditary neuropathy with liability to pressure palsy is characterized by acute, painless, recurrent mononeuropathies secondary to minor trauma or compression. A 16-year-old boy had the first episode of right foot drop after minor motorcycle accident. Electromyography revealed conduction block and slowing velocity conduction of the right deep peroneal nerve at the fibular head. After motor rehabilitation, he fully recovered. Six months later he had the second episode of foot drop in the opposite site after prolonged squatting position. Electromyography revealed sensorimotor polyneuropathy of left peroneal, sural, posterior tibial, and deep peroneal nerves and also of ulnar, radial, and median nerves of both upper limbs. Histological examination revealed sensory nerve demyelination and focal thickenings of myelin fibers. The diagnosis of hereditary neuropathy with liability to pressure palsy was confirmed by PMP22 deletion of chromosome 17p11.2. He started motor rehabilitation and avoidance of stressing factors with progressive recovery. After one-year followup, he was completely asymptomatic. Recurrent bilateral foot drop history, “sausage-like” swellings of myelin in histological examination, and the results of electromyography led the authors to consider the diagnosis despite negative family history. The authors highlight this rare disease in pediatric population and the importance of high index of clinical suspicion for its diagnosis.

  4. The unique case of foot drop secondary to a large ovarian cyst.

    Science.gov (United States)

    Ahmad, Maleeha; Kumar, Aditaya; Thomson, Simon

    2014-08-01

    We describe the unique case of a 58-year-old woman who presented with right leg radiculopathy caused by an ovarian cyst mimicking lumbar pathology. A review of the literature shows that this is a rare case where a histologically confirmed benign ovarian cystadenoma (of indeterminate type) is shown to cause foot drop and radiculopathy.

  5. Acceptability and Potential Effectiveness of a Foot Drop Stimulator in Children and Adolescents with Cerebral Palsy

    Science.gov (United States)

    Prosser, Laura A.; Curatalo, Lindsey A.; Alter, Katharine E.; Damiano, Diane L.

    2012-01-01

    Aim: Ankle-foot orthoses are the standard of care for foot drop in cerebral palsy (CP), but may overly constrain ankle movement and limit function in those with mild CP. Functional electrical stimulation (FES) may be a less restrictive and more effective alternative, but has rarely been used in CP. The primary objective of this study was to…

  6. Foot drop caused by lumbar degenerative disease: clinical features, prognostic factors of surgical outcome and clinical stage.

    Directory of Open Access Journals (Sweden)

    Kun Liu

    Full Text Available OBJECTIVE: The purpose of this study was to analyze the clinical features and prognostic factors of surgical outcome of foot drop caused by lumbar degenerative disease and put forward the clinical stage. METHODS: We retrospectively reviewed 135 patients with foot drop due to lumbar degenerative disease. The clinical features and mechanism were analyzed. Age, sex, duration of palsy, preoperative muscle strength of tibialis anterior (TA, sensation defect of affected lower limb, affected foot, diagnosis and compressed nerve roots were recorded and compared with surgical outcome. RESULTS: Foot drop was observed in 8.1% of all inpatients of lumbar degenerative disease. L5 nerve root compression was observed in 126 of all 135 patients (93.3%. Single, double and triple roots compression was observed respectively in 43, 83, and 9 patients (31.9%, 61.5%, and 6.6%. But there was no significant relationship between preoperative muscle strength of TA and the number of compressed roots. The muscle strength of TA was improved in 113 (83.7% patients after surgery, but it reached to >=4 in only 21 (15.6% patients. Improvement of the muscle strength of TA was almost stable at the 6-month follow-up. At the last follow-up, the muscle strength of TA was 1, 2, 3, 4, 5 respectively in 28, 24, 62, 13, 8 patients. Multivariate logistic regression showed duration of palsy (p=0.0360, OR=2.543, preoperative muscle strength of TA (p=0.0064, OR=5.528 and age (p=0.0309, OR=3.208 were factors that influenced recovery following an operation. CONCLUSIONS: L5 nerve root was most frequently affected. The muscle strength of TA improved in most patients after surgery, but few patients can get a good recovery from foot drop. Patients of shorter duration of palsy, better preoperative muscle strength of TA and younger age showed a better surgical outcome.

  7. Prediction of Postoperative Clinical Recovery of Drop Foot Attributable to Lumbar Degenerative Diseases, via a Bayesian Network.

    Science.gov (United States)

    Takenaka, Shota; Aono, Hiroyuki

    2017-03-01

    Drop foot resulting from degenerative lumbar diseases can impair activities of daily living. Therefore, predictors of recovery of this symptom have been investigated using univariate or/and multivariate analyses. However, the conclusions have been somewhat controversial. Bayesian network models, which are graphic and intuitive to the clinician, may facilitate understanding of the prognosis of drop foot resulting from degenerative lumbar diseases. (1) To show a layered correlation among predictors of recovery from drop foot resulting from degenerative lumbar diseases; and (2) to develop support tools for clinical decisions to treat drop foot resulting from lumbar degenerative diseases. Between 1993 and 2013, we treated 141 patients with decompressive lumbar spine surgery who presented with drop foot attributable to degenerative diseases. Of those, 102 (72%) were included in this retrospective study because they had drop foot of recent development and had no diseases develop that affect evaluation of drop foot after surgery. Specifically, 28 (20%) patients could not be analyzed because their records were not available at a minimum of 2 years followup after surgery and 11 (8%) were lost owing to postoperative conditions that affect the muscle strength evaluation. Eight candidate variables were sex, age, herniated soft disc, duration of the neurologic injury (duration), preoperative tibialis anterior muscle strength (pretibialis anterior), leg pain, cauda equina syndrome, and number of involved levels. Manual muscle testing was used to assess the tibialis anterior muscle strength. Drop foot was defined as a tibialis anterior muscle strength score of less than 3 of 5 (5 = movement against gravity and full resistance, 4 = movement against gravity and moderate resistance, 3 = movement against gravity through full ROM, 3- = movement against gravity through partial ROM, 2 = movement with gravity eliminated through full ROM, 1 = slight contraction but no movement, and 0 = no

  8. Inertial Gait Phase Detection for control of a drop foot stimulator: Inertial sensing for gait phase detection

    NARCIS (Netherlands)

    Kotiadis, D.; Hermens, Hermanus J.; Veltink, Petrus H.

    An Inertial Gait Phase Detection system was developed to replace heel switches and footswitches currently being used for the triggering of drop foot stimulators. A series of four algorithms utilising accelerometers and gyroscopes individually and in combination were tested and initial results are

  9. Statin-induced bilateral foot drop in a case of hypothyroidism

    Directory of Open Access Journals (Sweden)

    Neera Chaudhary

    2015-01-01

    Full Text Available Muscle involvement is a common manifestation of both clinical and subclinical hypothyroidism, with serum creatine kinase (CK elevation being probably the most common manifestation, and is seen in up to 90% of patients, but is usually mild (less than 10 times the upper limit of normal. Rhabdomyolysis is a distinctively uncommon presentation of hypothyroidism described usually in the setting of precipitating events such as strenuous exercise, alcohol, or statin use. Rarely rhabdomyolysis and myoedema seen in hypothyroidism can be complicated by the development of anterior compartment syndrome leading to neurovascular compression. We describe a case of a patient with hypothyroidism who developed acute onset bilateral foot drop on initiation of statins. This case highlights the need for cautious use of statins in patients at risk for rhabdomyolysis.

  10. Foot Drop after Ethanol Embolization of Calf Vascular Malformation: A Lesson on Nerve Injury

    International Nuclear Information System (INIS)

    Tay, Vincent Khwee-Soon; Mohan, P. Chandra; Liew, Wendy Kein Meng; Mahadev, Arjandas; Tay, Kiang Hiong

    2013-01-01

    Ethanol is often used in sclerotherapy to treat vascular malformations. Nerve injury is a known complication of this procedure. However, the management of this complication is not well described in literature. This case describes a 10-year-old boy with a slow flow vascular malformation in the right calf who underwent transarterial ethanol embolization following prior unsuccessful direct percutaneous sclerotherapy. The development of a dense foot drop that subsequently recovered is described, and the management of this uncommon but distressful complication is discussed

  11. Foot Drop after Ethanol Embolization of Calf Vascular Malformation: A Lesson on Nerve Injury

    Energy Technology Data Exchange (ETDEWEB)

    Tay, Vincent Khwee-Soon, E-mail: vincentkstay@gmail.com [Singapore General Hospital, Department of Plastic, Reconstructive, and Aesthetic Surgery (Singapore); Mohan, P. Chandra, E-mail: chandra.mohan@sgh.com.sg [Singapore General Hospital, Department of Diagnostic Radiology (Singapore); Liew, Wendy Kein Meng, E-mail: wendy.liew.km@kkh.com.sg [KK Women' s and Children' s Hospital, Department of Paediatrics (Neurology Service) (Singapore); Mahadev, Arjandas, E-mail: arjandas.mahadev@kkh.com.sg [KK Women' s and Children' s Hospital, Department of Orthopaedic Surgery (Singapore); Tay, Kiang Hiong, E-mail: tay.kiang.hiong@sgh.com.sg [Singapore General Hospital, Department of Diagnostic Radiology (Singapore)

    2013-08-01

    Ethanol is often used in sclerotherapy to treat vascular malformations. Nerve injury is a known complication of this procedure. However, the management of this complication is not well described in literature. This case describes a 10-year-old boy with a slow flow vascular malformation in the right calf who underwent transarterial ethanol embolization following prior unsuccessful direct percutaneous sclerotherapy. The development of a dense foot drop that subsequently recovered is described, and the management of this uncommon but distressful complication is discussed.

  12. Gait phase detection from sciatic nerve recordings in functional electrical stimulation systems for foot drop correction

    International Nuclear Information System (INIS)

    Chu, Jun-Uk; Song, Kang-Il; Han, Sungmin; Suh, Jun-Kyo Francis; Choi, Kuiwon; Youn, Inchan; Lee, Soo Hyun; Kang, Ji Yoon; Hwang, Dosik

    2013-01-01

    Cutaneous afferent activities recorded by a nerve cuff electrode have been used to detect the stance phase in a functional electrical stimulation system for foot drop correction. However, the implantation procedure was difficult, as the cuff electrode had to be located on the distal branches of a multi-fascicular nerve to exclude muscle afferent and efferent activities. This paper proposes a new gait phase detection scheme that can be applied to a proximal nerve root that includes cutaneous afferent fibers as well as muscle afferent and efferent fibers. To test the feasibility of this scheme, electroneurogram (ENG) signals were measured from the rat sciatic nerve during treadmill walking at several speeds, and the signal properties of the sciatic nerve were analyzed for a comparison with kinematic data from the ankle joint. On the basis of these experiments, a wavelet packet transform was tested to define a feature vector from the sciatic ENG signals according to the gait phases. We also propose a Gaussian mixture model (GMM) classifier and investigate whether it could be used successfully to discriminate feature vectors into the stance and swing phases. In spite of no significant differences in the rectified bin-integrated values between the stance and swing phases, the sciatic ENG signals could be reliably classified using the proposed wavelet packet transform and GMM classification methods. (paper)

  13. Effect of kinesiotaping, non-elastic taping and bracing on segmental foot kinematics during drop landing in healthy subjects and subjects with chronic ankle instability.

    Science.gov (United States)

    Kuni, B; Mussler, J; Kalkum, E; Schmitt, H; Wolf, S I

    2016-09-01

    To evaluate the effects of kinesiotape, non-elastic tape, and soft brace on segmental foot kinematics during drop landing in subjects with chronic ankle instability and healthy subjects. Controlled study with repeated measurements. Three-dimensional motion analysis laboratory. Twenty participants with chronic ankle instability and 20 healthy subjects. The subjects performed drop landings with 17 retroreflective markers on the foot and lower leg in four conditions: barefoot, with kinesiotape, with non-elastic tape and with a soft brace. Ranges of motion of foot segments using a foot measurement method. In participants with chronic ankle instability, midfoot movement in the frontal plane (inclination of the medial arch) was reduced significantly by non-elastic taping, but kinesiotaping and bracing had no effect. In healthy subjects, both non-elastic taping and bracing reduced that movement. In both groups, non-elastic taping and bracing reduced rearfoot excursion in inversion/eversion significantly, which indicates a stabilisation effect. No such effect was found with kinesiotaping. All three methods reduced maximum plantar flexion significantly. Non-elastic taping stabilised the midfoot best in patients with chronic ankle instability, while kinesiotaping did not influence foot kinematics other than to stabilise the rearfoot in the sagittal plane. ClinicalTrials.gov NCT01810471. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  14. A Novel Method for Measuring In-Shoe Navicular Drop during Gait

    Directory of Open Access Journals (Sweden)

    Henrik Karstoft

    2012-08-01

    Full Text Available Analysis of foot movement is essential in the treatment and prevention of foot-related disorders. Measuring the in-shoe foot movement during everyday activities, such as sports, has the potential to become an important diagnostic tool in clinical practice. The current paper describes the development of a thin, flexible and robust capacitive strain sensor for the in-shoe measurement of the navicular drop. The navicular drop is a well-recognized measure of foot movement. The position of the strain sensor on the foot was analyzed to determine the optimal points of attachment. The sensor was evaluated against a state-of-the-art video-based system that tracks reflective markers on the bare foot. Preliminary experimental results show that the developed strain sensor is able to measure navicular drop on the bare foot with an accuracy on par with the video-based system and with a high reproducibility. Temporal comparison of video-based, barefoot and in-shoe measurements indicate that the developed sensor measures the navicular drop accurately in shoes and can be used without any discomfort for the user.

  15. 45-FOOT HIGH DROP TOWER

    Data.gov (United States)

    Federal Laboratory Consortium — The Drop Tower is used to simulate and measure the impact shocks that are exerted on parachute loads when they hit the ground. It is also used for HSL static lift to...

  16. Free drop impact analysis of shipping cask

    International Nuclear Information System (INIS)

    Pfeiffer, P.A.; Kennedy, J.M.

    1989-01-01

    The WHAMS-2D and WHAMS-3D codes were used to analyze the dynamic response of the RAS/TREAT shielded shipping cask subjected to transient leadings for the purpose of assessing potential damage to the various components that comprise the the cask. The paper describes how these codes can be used to provide and intermediate level of detail between full three-dimensional finite element calculations and hand calculations which are cost effective for design purposes. Three free drops were adressed: (1) a thirty foot axial drop on either end; (2) a thirty foot oblique angle drop with the cask having several different orientations from the vertical with impact on the cask corner; and (3) a thirty foot side drop with simultaneous impact on the lifting trunnion and the bottom end. Results are presented for two models of the side and oblique angle drops; one model includes only the mass of the lapped sleeves of depleted uranium (DU) while the other includes the mass and stiffness of the DU. The results of the end drop analyses are given for models with and without imperfections in the cask. Comparison of the analysis to hand calculations and simplified analyses are given. (orig.)

  17. Functional electrical stimulation and ankle foot orthoses provide equivalent therapeutic effects on foot drop: A meta-analysis providing direction for future research

    Directory of Open Access Journals (Sweden)

    Sarah Prenton

    2017-10-01

    Full Text Available Objective: To compare the randomized controlled trial evidence for therapeutic effects on walking of functional electrical stimulation and ankle foot orthoses for foot drop caused by central nervous system conditions. Data sources: MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials, REHABDATA, PEDro, NIHR Centre for Reviews and Dissemination, Scopus and clinicaltrials.gov. Study selection: One reviewer screened titles/abstracts. Two independent reviewers then screened the full articles. Data extraction: One reviewer extracted data, another screened for accuracy. Risk of bias was assessed by 2 independent reviewers using the Cochrane Risk of Bias Tool. Data synthesis: Eight papers were eligible; 7 involving participants with stroke and 1 involving participants with cerebral palsy. Two papes reporting different measures from the same trial were grouped, resulting in 7 synthesized randomized controlled trials (n= 464. Meta-analysis of walking speed at final assessment (p = 0.46, for stroke participants (p = 0.54 and after 4–6 weeks’ use (p = 0.49 showed equal improvement for both devices. Conclusion: Functional electrical stimulation and ankle foot orthoses have an equally positive therapeutic effect on walking speed in non-progressive central nervous system diagnoses. The current randomized controlled trial evidence base does not show whether this improvement translates into the user’s own environment or reveal the mechanisms that achieve that change. Future studies should focus on measuring activity, muscle activity and gait kinematics. They should also report specific device details, capture sustained therapeutic effects and involve a variety of central nervous system diagnoses.

  18. Walking Training with Foot Drop Stimulator Controlled by a Tilt Sensor to Improve Walking Outcomes: A Randomized Controlled Pilot Study in Patients with Stroke in Subacute Phase

    Directory of Open Access Journals (Sweden)

    G. Morone

    2012-01-01

    Full Text Available Foot drop is a quite common problem in nervous system disorders. Neuromuscular electrical stimulation (NMES has showed to be an alternative approach to correct foot drop improving walking ability in patients with stroke. In this study, twenty patients with stroke in subacute phase were enrolled and randomly divided in two groups: one group performing the NMES (i.e. Walkaide Group, WG and the Control Group (CG performing conventional neuromotor rehabilitation. Both groups underwent the same amount of treatment time. Significant improvements of walking speed were recorded for WG (% than for CG (%, as well as in terms of locomotion (Functional Ambulation Classification score: . In terms of mobility and force, ameliorations were recorded, even if not significant (Rivermead Mobility Index: ; Manual Muscle Test: . Similar changes between groups were observed for independence in activities of daily living, neurological assessments, and spasticity reduction. These results highlight the potential efficacy for patients affected by a droop foot of a walking training performed with a neurostimulator in subacute phase.

  19. Poststroke Muscle Architectural Parameters of the Tibialis Anterior and the Potential Implications for Rehabilitation of Foot Drop

    Directory of Open Access Journals (Sweden)

    John W. Ramsay

    2014-01-01

    Full Text Available Poststroke dorsiflexor weakness and paretic limb foot drop increase the risk of stumbling and falling and decrease overall functional mobility. It is of interest whether dorsiflexor muscle weakness is primarily neurological in origin or whether morphological differences also contribute to the impairment. Ten poststroke hemiparetic individuals were imaged bilaterally using noninvasive medical imaging techniques. Magnetic resonance imaging was used to identify changes in tibialis anterior muscle volume and muscle belly length. Ultrasonography was used to measure fascicle length and pennation angle in a neutral position. We found no clinically meaningful bilateral differences in any architectural parameter across all subjects, which indicates that these subjects have the muscular capacity to dorsiflex their foot. Therefore, poststroke dorsiflexor weakness is primarily neural in origin and likely due to muscle activation failure or increased spasticity of the plantar flexors. The current finding suggests that electrical stimulation methods or additional neuromuscular retraining may be more beneficial than targeting muscle strength (i.e., increasing muscle mass.

  20. Differential diagnosis and recovery of acute bilateral foot drop in a patient with a history of low back pain: A case report.

    Science.gov (United States)

    Lomaglio, Melanie; Canale, Bob

    2017-06-01

    Acute bilateral foot drop is rare and may be due to peripheral or central lesions. The purpose of this case report was to describe the differential diagnosis and recovery of a patient with low back pain (LBP) that awoke with bilateral foot drop. A 39-year-old man with a history of LBP awoke with a steppage gait pattern. Spinal imaging and tapping were negative for sinister pathologies. A subsequent history taken by the physical therapist uncovered that the patient had previously taken a narcotic and slept in a kneeling position to relieve his LBP. Strength and sensory testing revealed isolated impairments in the fibular nerve distribution, and bilateral fibular palsy was suspected and later confirmed with electrophysiological studies. Surgical fibular nerve decompression was performed, and the patient underwent physical therapy. Five months later the patient demonstrated antigravity strength and a partial return of sensation. By 17 months, his Lower Extremity Functional Scale had improved from 17/80 to 78/80, revealing a near complete recovery. The patient's history of LBP was a "red herring" that delayed the diagnosis and caused undue stress to the patient. This case stresses the importance of a thorough history and clinical examination.

  1. An extraordinary cause for the low-back pain and foot drop: hydatid cyst

    International Nuclear Information System (INIS)

    Incedayi, M.; Sivrioglu, A.; Ak, M.; Sonmez, G.; Mutlu, H.

    2012-01-01

    Full text: A 35-years-old male patient applied to our clinic with pain in the left gluteal region which had started 5 months ago, and left foot drop. Lumbosacral Magnetic Resonance Imaging (MRI) was performed by the reason of a probable lumbar disc hernia, but the results did not demonstrate any pathology to explain these symptoms. At the lower abdominal MRI, a mass lesion with dimensions of 14x2.5 cm, in which cystic areas were monitored without a significant contrast involvement was demonstrated in the left paravertebral area, extending along the psoas anterior. At the left sciatic nerve, a thickening secondary to the lesion pressure was detected. The histopathological diagnosis was verified as hydatid cyst. In the cases where peripheral nerve pressure findings are observed, but a lumbar disc hernia cannot be detected, existence of a mass which may exert pressure on the peripheral nerves such as the sciatic nerve should be taken into consideration. Especially in the endemic regions, in case of the existence of a retroperitoneal cystic mass, hydatid cyst should be considered as a cause

  2. Impedance and electrically evoked compound action potential (ECAP drop within 24 hours after cochlear implantation.

    Directory of Open Access Journals (Sweden)

    Joshua Kuang-Chao Chen

    Full Text Available Previous animal study revealed that post-implantation electrical detection levels significantly declined within days. The impact of cochlear implant (CI insertion on human auditory pathway in terms of impedance and electrically evoked compound action potential (ECAP variation within hours after surgery remains unclear, since at this time frequency mapping can only commence weeks after implantation due to factors associated with wound conditions. The study presented our experiences with regards to initial switch-on within 24 hours, and thus the findings about the milieus inside cochlea within the first few hours after cochlear implantation in terms of impedance/ECAP fluctuations. The charts of fifty-four subjects with profound hearing impairment were studied. A minimal invasive approach was used for cochlear implantation, characterized by a small skin incision (≈ 2.5 cm and soft techniques for cochleostomy. Impedance/ECAP was measured intro-operatively and within 24 hours post-operatively. Initial mapping within 24 hours post-operatively was performed in all patients without major complications. Impedance/ECAP became significantly lower measured within 24 hours post-operatively as compared with intra-operatively (p<0.001. There were no differences between pre-operative and post-operative threshold for air-conduction hearing. A significant drop of impedance/ECAP in one day after cochlear implantation was revealed for the first time in human beings. Mechanisms could be related to the restoration of neuronal sensitivity to the electrical stimulation, and/or the interaction between the matrix enveloping the electrodes and the electrical stimulation of the initial switch-on. Less wound pain/swelling and soft techniques both contributed to the success of immediate initial mapping, which implied a stable micro-environment inside the cochlea despite electrodes insertion. Our research invites further studies to correlate initial impedance/ECAP changes

  3. Increased medial foot loading during drop jump in subjects with patellofemoral pain

    DEFF Research Database (Denmark)

    Rathleff, Michael S; Richter, Camilla; Brushøj, Christoffer

    2014-01-01

    PURPOSE: To compare medial-to-lateral plantar forces during drop jump and single leg squat in individuals with and without patellofemoral pain. METHODS: This cross-sectional study compared 23 young adults with patellofemoral pain to 20 age- and sex-matched controls without knee pain. The plantar...... pressure distribution was collected during drop jump and single leg squat using pressure-sensitive Pedar insoles, inserted into a standard flat shoe. The primary outcome was the medial-to-lateral force, quantified as the peak force under the medial forefoot as the percentage of force under the total...... forefoot during drop jump. Secondary outcomes included peak medial-to-lateral force during single leg squat and mean forces during drop jump and single leg squat. RESULTS: The primary outcome showed that individuals with patellofemoral pain had a 22 % higher medial-to-lateral peak force during drop jump...

  4. Foot Skin Ischemic Necrosis following Heel Prick in a Newborn

    Directory of Open Access Journals (Sweden)

    Esad Koklu

    2013-01-01

    Full Text Available There are only a few reports on side effects after heel prick in neonates although heel prick has been performed all over the world for many years. The medicine staff had obtained only a drop of blood by pricking the baby’s heel using a lancet without compressing the heel or foot to measure his blood glucose level 3 hours after birth. However he developed a severe and hemorrhagic skin reaction on his entire left foot, beginning 30 minutes after obtaining the drop of blood by pricking the baby’s heel using a lancet. The lesion, which was treated with topical mupirocin and povidone-iodine solution daily, slowly decreased in size and had almost fully resolved within 3 weeks. He was healthy and 9 months old at the time of writing this paper. We herein report a case of foot skin ischemic necrosis following heel prick in a newborn. To our knowledge this patient is the first case of foot skin ischemic necrosis due to heel prick in newborns.

  5. Perioperative nursing for patients with diabetic foot receiving endovascular interventional therapy

    International Nuclear Information System (INIS)

    Yang Yang; Wang Feng; Li Ke; Li Cheng; Ji Donghua

    2010-01-01

    Objective: To study the effect of perioperative nursing on the living quality of patients with diabetic foot who are treated with endovascular interventional therapy. Methods: Specific perioperative nursing care plan was accordingly designed for 43 patients with diabetic foot. Endovascular balloon angioplasty and stent implantation were formed in these patients to treat their diabetic foot. The clinical results were observed. Results: Perioperative nursing effectively improved patient's limb blood supply, enhanced the healing of diabetic foot ulceration and increased the possibility of limb preservation. Conclusion: Endovascular therapy combined with corresponding perioperative nursing care can benefit more patients with diabetic foot. (authors)

  6. COMPARISON OF FOOT TAPING VERSUS CUSTOM-MADE MEDIAL ARCH SUPPORT ON PRONATED FLATFOOT IN SCHOOL GOING CHILDREN

    Directory of Open Access Journals (Sweden)

    K. Vadivelan

    2015-06-01

    Full Text Available Background: Flatfoot may exist as an isolated pathology or as part of a larger clinical entity. These entities include generalized ligamentous laxity, neurologic and muscular abnormalities, genetic conditions, collagen disorders and structural disorder. Flat foot is found to be associated with pronated foot. The objective of the study is to compare the effectiveness of foot taping versus custom-made medial arch support on pronated flatfoot in school going children. Methods: 60 students out of 130, aged 10 to 12 years were selected on the basis of inclusion criteria and divided into three groups from two different higher secondary schools at Srikalahasti, in Chittoor district, Andhra Pradesh. Group-A received custom-made medial arch support and foot strengthening exercises, Group-B received kinesio taping and foot strengthening exercises , Group-C received foot strengthening exercises for 4 weeks. The values of navicular drop test were taken after 4 weeks of study. The pre and post-test values were compared and results were tabulated. Results: All three groups showed significant improvement in navicular drop separately. No significant difference was found in the post-test values of group-A, group-B, group-C (p>0.05. However, the reduction of navicular drop was slightly more in group-B subjects treated with kinesio tape and foot strengthening exercises when compared with other two interventions. Conclusion: The study concluded that foot taping, custom-made medial arch support and foot strengthening exercises were found to be effective on pronated flatfoot in school going children aged 10 to 12 years.

  7. Foot ulcer risk and location in relation to prospective clinical assessment of foot shape and mobility among persons with diabetes.

    Science.gov (United States)

    Cowley, Matthew S; Boyko, Edward J; Shofer, Jane B; Ahroni, Jessie H; Ledoux, William R

    2008-11-01

    We assessed baseline clinical foot shape for 2939 feet of diabetic subjects who were monitored prospectively for foot ulceration. Assessments included hammer/claw toes, hallux valgus, hallux limitus, prominent metatarsal heads, bony prominences, Charcot deformity, plantar callus, foot type, muscle atrophy, ankle and hallux mobility, and neuropathy. Risk factors were linked to ulcer occurrence and location via a Cox proportional hazards model. Hammer/claw toes (hazard ratio [HR] (95% confidence interval [CI])=1.43 (1.06, 1.94) p=0.02), marked hammer/claw toes (HR=1.77 (1.18, 2.66) p=0.006), bony prominences (HR=1.38 (1.02, 1.88), p=0.04), and foot type (Charcot or drop foot vs. neutrally aligned) (HR=2.34 (1.33, 4.10), p=0.003) were significant risk factors for ulceration adjusting for age, body mass index, insulin medication, ulcer history and amputation history. With adjustment for neuropathy only hammer/claw toes (HR=1.40 (1.03, 1.90), p=0.03) and foot type (HR=1.76 (1.04, 3.04), p=0.05) were significantly related to ulceration. However, there was no relationship between ulcer location and foot deformity. Certain foot deformities were predictive of ulceration, although there was no relationship between clinical foot deformity and ulcer location.

  8. Physical test report to drop test of a 9975 radioactive material shipping packaging

    International Nuclear Information System (INIS)

    Blanton, P.S.

    1997-01-01

    This report presents the drop test results for the 9975 radioactive material shipping package being dropped 30 feet onto a unyielding surface followed by a 40-inch puncture pin drop. The purpose of these drops was to show that the package lid would remain attached to the drum. The 30-foot drop was designed to weaken the lid closure lug while still maintaining maximum extension of the lugs from the drum surface. This was accomplished by angling the drum approximately 30 degrees from horizontal in an inverted position. In this position, the drum was rotated slightly so as not to embed the closure lugs into the drum as a result of the 30-foot drop. It was determined that this orientation would maximize deformation to the closure ring around the closure lug while still maintaining the extension of the lugs from the package surface. The second drop was from 40 inches above a 40-inch tall 6-inch diameter puncture pin. The package was angled 10 degrees from vertical and aligned over the puncture pin to solidly hit the drum lug(s) in an attempt to disengage the lid when dropped.Tests were performed in response to DOE EM-76 review Q5 inquires that questioned the capability of the 9975 drum lid to remain in place under this test sequence. Two packages were dropped utilizing this sequence, a 9974 and 9975. Test results for the 9974 package are reported in WSRC-RP-97-00945. A series of 40-inch puncture pin tests were also performed on undamaged 9975 and 9974 packages

  9. Select injury-related variables are affected by stride length and foot strike style during running.

    Science.gov (United States)

    Boyer, Elizabeth R; Derrick, Timothy R

    2015-09-01

    Some frontal plane and transverse plane variables have been associated with running injury, but it is not known if they differ with foot strike style or as stride length is shortened. To identify if step width, iliotibial band strain and strain rate, positive and negative free moment, pelvic drop, hip adduction, knee internal rotation, and rearfoot eversion differ between habitual rearfoot and habitual mid-/forefoot strikers when running with both a rearfoot strike (RFS) and a mid-/forefoot strike (FFS) at 3 stride lengths. Controlled laboratory study. A total of 42 healthy runners (21 habitual rearfoot, 21 habitual mid-/forefoot) ran overground at 3.35 m/s with both a RFS and a FFS at their preferred stride lengths and 5% and 10% shorter. Variables did not differ between habitual groups. Step width was 1.5 cm narrower for FFS, widening to 0.8 cm as stride length shortened. Iliotibial band strain and strain rate did not differ between foot strikes but decreased as stride length shortened (0.3% and 1.8%/s, respectively). Pelvic drop was reduced 0.7° for FFS compared with RFS, and both pelvic drop and hip adduction decreased as stride length shortened (0.8° and 1.5°, respectively). Peak knee internal rotation was not affected by foot strike or stride length. Peak rearfoot eversion was not different between foot strikes but decreased 0.6° as stride length shortened. Peak positive free moment (normalized to body weight [BW] and height [h]) was not affected by foot strike or stride length. Peak negative free moment was -0.0038 BW·m/h greater for FFS and decreased -0.0004 BW·m/h as stride length shortened. The small decreases in most variables as stride length shortened were likely associated with the concomitant wider step width. RFS had slightly greater pelvic drop, while FFS had slightly narrower step width and greater negative free moment. Shortening one's stride length may decrease or at least not increase propensity for running injuries based on the variables

  10. Visualization study of film drops produced by bubble bursting

    International Nuclear Information System (INIS)

    Ma Chao; Bo Hanliang

    2012-01-01

    The phenomenon that bubble bursting results in drops production is common in the steam generator of the nuclear power plant, and the fine drops generated by this way is one of the most important source of the drop entrainment in the vapor stream. The visualization experiment about the film drops produced by the bursting bubbles at a free water surface was studied using a high-speed video camera. The results show that the bubble cap breaks up in a single point, within the limits of bubble size in the experiment at present. The whole process can be distinguished into four successive stages: A primary inertial drainage, the bubble cap puncture at the foot or on the top, the film rolls-up and the liquid ring appearing with the hole expanding, and fine film drops emission under the effect of destabilization of a Rayleigh-Taylor type. The expression about the bubble radius and the film drops number is obtain by fitting the experiment data at the bubble radius range from 3-25 mm. The result trend agrees well with the previous work. (authors)

  11. Digital Radiography of a Drop Tested 9975 Radioactive Materials Packaging

    International Nuclear Information System (INIS)

    Blanton, P.S.

    2001-01-01

    This paper discusses the use of radiography as a tool for evaluating damage to radioactive material packaging subjected to regulatory accident conditions. The Code of Federal Regulations, 10 CFR 71, presents the performance based requirements that must be used in the development (design, fabrication and testing) of a radioactive material packaging. The use of various non-destructive examination techniques in the fabrication of packages is common. One such technique is the use of conventional radiography in the examination of welds. Radiography is conventional in the sense that images are caught one at a time on film stock. Most recently, digital radiography has been used to characterize internal damage to a package subjected to the 30-foot hypothetical accident conditions (HAC) drop. Digital radiography allows for real time evaluation of the item being inspected. This paper presents a summary discussion of the digital radiographic technique and an example of radiographic results of a 9975 package following the HAC 30-foot drop

  12. Benchmarking of the computer code and the thirty foot side drop analysis for the Shippingport (RPV/NST package)

    International Nuclear Information System (INIS)

    Bumpus, S.E.; Gerhard, M.A.; Hovingh, J.; Trummer, D.J.; Witte, M.C.

    1989-01-01

    This paper presents the benchmarking of a finite element computer code and the subsequent results from the code simulating the 30 foot side drop impact of the RPV/NST transport package from the decommissioned Shippingport Nuclear Power Station. The activated reactor pressure vessel (RPV), thermal shield, and other reactor external components were encased in concrete contained by the neutron shield tank (NST) and a lifting skirt. The Shippingport RPV/NST package, a Type B Category II package, weighs approximately 900 tons and has 17.5 ft diameter and 40.7 ft. length. For transport of the activated components from Shippingport to the burial site, the Safety Analysis Report for Packaging (SARP) demonstrated that the package can withstand the hypothetical accidents of DOE Order 5480.3 including 10 CFR 71. Mathematical simulations of these accidents can substitute for actual tests if the simulated results satisfy the acceptance criteria. Any such mathematical simulation, including the modeling of the materials, must be benchmarked to experiments that duplicate the loading conditions of the tests. Additional confidence in the simulations is justified if the test specimens are configured similar to the package

  13. Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale.

    Science.gov (United States)

    Diaz, Delia H; Casas, Oscar; Pallas-Areny, Ramon

    2010-01-01

    Electronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart rate, cardiac output and systolic blood pressure. Therefore, weighing scales may suit intermittent monitoring in e-health and patient screening. Scales intended for bioelectrical impedance analysis (BIA) have also been proposed to estimate the heart rate by amplifying the pulsatile impedance component superimposed on the basal impedance. However, electronic weighing scales cannot easily obtain the BCG from people that have a single leg neither are bioimpedance measurements between both feet recommended for people wearing a pacemaker or other electronic implants, neither for pregnant women. We propose a method to detect the heart rate (HR) from bioimpedance measured in a single foot while standing on an bathroom weighting scale intended for BIA. The electrodes built in the weighing scale are used to apply a 50 kHz voltage between the outer electrode pair and to measure the drop in voltage across the inner electrode pair. The agreement with the HR simultaneously obtained from the ECG is excellent. We have also compared the drop in voltage across the waist and the thorax with that obtained when measuring bioimpedance between both feet to compare the possible risk of the proposed method to that of existing BIA scales.

  14. ActiGait® A Partly Implantable Drop-Foot Stimulator System

    DEFF Research Database (Denmark)

    Larsen, Birgit Tine; Partriciu, Andrei

    2013-01-01

    application of the ActiGait® during market introduction, additional monitoring tools were applied and developed such as preoperative and postoperative magnetic resonance imaging (MRI), intraoperative fluoroscopy, and surface recordings of the artifacts generated by the electrical stimulation of the nerve...

  15. Foot Function, Foot Pain, and Falls in Older Adults: The Framingham Foot Study.

    Science.gov (United States)

    Awale, Arunima; Hagedorn, Thomas J; Dufour, Alyssa B; Menz, Hylton B; Casey, Virginia A; Hannan, Marian T

    2017-01-01

    Although foot pain has been linked to fall risk, contributions of pain severity, foot posture, or foot function are unclear. These factors were examined in a cohort of older adults. The purpose of this study was to examine the associations of foot pain, severity of foot pain, and measures of foot posture and dynamic foot function with reported falls in a large, well-described cohort of older adults from the Framingham Foot Study. Foot pain, posture, and function were collected from Framingham Foot Study participants who were queried about falls over the past year (0, 1, and ≥2 falls). Logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (CIs) for the relation of falls with foot pain, pain severity, foot posture, and foot function adjusting for covariates. The mean age of the 1,375 participants was 69 years; 57% were female, and 21% reported foot pain (40% mild pain, 47% moderate pain, and 13% severe pain). One-third reported falls in the past year (1 fall: n = 263, ≥2 falls: n = 152). Foot pain was associated with a 62% increased odds of recurrent falls. Those with moderate and severe foot pain showed increased odds of ≥2 falls (OR 1.78, CI 1.06-2.99, and OR 3.25, CI 1.65-7.48, respectively) compared to those with no foot pain. Foot function was not associated with falls. Compared to normal foot posture, those with planus foot posture had 78% higher odds of ≥2 falls. Higher odds of recurrent falls were observed in individuals with foot pain, especially severe foot pain, as well as in individuals with planus foot posture, indicating that both foot pain and foot posture may play a role in increasing the risk of falls among older adults. © 2017 S. Karger AG, Basel.

  16. The influence of shoe drop on the kinematics and kinetics of children tennis players.

    Science.gov (United States)

    Herbaut, Alexis; Chavet, Pascale; Roux, Maxime; Guéguen, Nils; Gillet, Christophe; Barbier, Franck; Simoneau-Buessinger, Emilie

    2016-11-01

    This study investigated the immediate effects of reducing the shoe drop (i.e. the difference between the heel and the forefoot height) on the kinematics and kinetics of the lower extremities of children tennis players performing a tennis-specific movement. Thirteen children tennis players performed a series of simulated open stance forehands wearing 3 pairs of shoes differing only in the drop: 0 (D0), 6 (D6) and the control condition of 12 mm (D12). Two embedded forceplates and a motion capture system were used to analyse the ground reaction forces and ankle and knee joint angles and moments of the leading lower limb. In D6 compared with D12, the peak impact force was reduced by 24% (p = .004) and the ankle was less dorsiflexed at foot strike (p = .037). In D0 compared with D12, the peak impact force was reduced by 17% (p = .049), the ankle was less dorsiflexed at foot strike (p = .045) and the knee was more flexed at foot strike (p = .007). In addition, 4 out of 13 participants (31%) presented a forefoot strike pattern for some of the trials in D0. No difference was observed across shoe conditions for the peak knee extensor moment (p = .658) or the peak ankle plantarflexor moment (p = .071). The results provide preliminary data supporting the hypothesis that for children tennis players, using a 6-mm lower shoe drop might reduce heel impact forces and thus limit potentially impact-related injuries.

  17. The physiological cost index of walking with a powered knee-ankle-foot orthosis in subjects with poliomyelitis: A pilot study.

    Science.gov (United States)

    Arazpour, Mokhtar; Ahmadi Bani, Monireh; Samadian, Mohammad; Mousavi, Mohammad E; Hutchins, Stephen W; Bahramizadeh, Mahmood; Curran, Sarah; Mardani, Mohammad A

    2016-08-01

    A powered knee-ankle-foot orthosis was developed to provide restriction of knee flexion during stance phase and active flexion and extension of the knee during swing phase of gait. The purpose of this study was to determine its effect on the physiological cost index, walking speed and the distance walked in people with poliomyelitis compared to when walking with a knee-ankle-foot orthosis with drop lock knee joints. Quasi experimental study. Seven subjects with poliomyelitis volunteered for the study and undertook gait analysis with both types of knee-ankle-foot orthosis. Walking with the powered knee-ankle-foot orthosis significantly reduced walking speed (p = 0.015) and the distance walked (p = 0.004), and also, it did not improve physiological cost index values (p = 0.009) compared to walking with the locked knee-ankle-foot orthosis. Using a powered knee-ankle-foot orthosis did not significantly improve any of the primary outcome measures during walking for poliomyelitis subjects. This powered knee-ankle-foot orthosis design did not improve the physiological cost index of walking for people with poliomyelitis when compared to walking with a knee-ankle-foot orthosis with drop lock knee joints. This may have been due to the short training period used or the bulky design and additional weight of the powered orthosis. Further research is therefore warranted. © The International Society for Prosthetics and Orthotics 2015.

  18. Prophylactic Vancomycin Drops Reduce the Severity of Early Bacterial Keratitis in Keratoprosthesis

    Science.gov (United States)

    Konstantopoulos, Aris; Tan, Xiao Wei; Goh, Gwendoline Tze Wei; Saraswathi, Padmanabhan; Chen, Liyan; Nyein, Chan Lwin; Zhou, Lei; Beuerman, Roger; Tan, Donald Tiang Hwee; Mehta, Jod

    2015-01-01

    Background Artificial cornea transplantation, keratoprosthesis, improves vision for patients at high risk of failure with human cadaveric cornea. However, post-operative infection can cause visual loss and implant extrusion in 3.2–17% of eyes. Long-term vancomycin drops are recommended following keratoprosthesis to prevent bacterial keratitis. Evidence, though, in support of this practice is poor. We investigated whether prophylactic vancomycin drops prevented bacterial keratitis in an animal keratoprosthesis model. Methodology Twenty-three rabbits were assigned either to a prophylactic group (n = 13) that received vancomycin 1.4% drops 5 times/day from keratoprosthesis implantation to sacrifice, or a non-prophylactic group (n = 10) that received no drops. All rabbits had Staphylococcus aureus inoculation into the cornea at 7–12 days post-implantation and were sacrificed at predetermined time-points. Prophylactic and non-prophylactic groups were compared with slit-lamp photography (SLP), anterior segment optical coherence tomography (AS-OCT), and histology, immunohistochemistry and bacterial quantification of excised corneas. Corneal vancomycin pharmacokinetics were studied in 8 additional rabbits. Results On day 1 post-inoculation, the median SLP score and mean±SEM AS-OCT corneal thickness (CT) were greater in the non-prophylactic than the prophylactic group (11 vs. 1, p = 0.049 and 486.9±61.2 vs. 327.4±37.1 μm, p = 0.029 respectively). On days 2 and 4, SLP scores and CT were not significantly different. Immunohistochemistry showed a greater CD11b+ve/non-CD11b+ve cell ratio in the non-prophylactic group (1.45 vs. 0.71) on day 2. Bacterial counts were not significantly different between the two groups. Corneal vancomycin concentration (2.835±0.383 μg/ml) exceeded minimum inhibitory concentration (MIC) for Staphylococcus aureus only after 16 days of vancomycin drops. Two of 3 rabbits still developed infection despite bacterial inoculation after 16 days of

  19. Prophylactic Vancomycin Drops Reduce the Severity of Early Bacterial Keratitis in Keratoprosthesis.

    Directory of Open Access Journals (Sweden)

    Aris Konstantopoulos

    Full Text Available Artificial cornea transplantation, keratoprosthesis, improves vision for patients at high risk of failure with human cadaveric cornea. However, post-operative infection can cause visual loss and implant extrusion in 3.2-17% of eyes. Long-term vancomycin drops are recommended following keratoprosthesis to prevent bacterial keratitis. Evidence, though, in support of this practice is poor. We investigated whether prophylactic vancomycin drops prevented bacterial keratitis in an animal keratoprosthesis model.Twenty-three rabbits were assigned either to a prophylactic group (n = 13 that received vancomycin 1.4% drops 5 times/day from keratoprosthesis implantation to sacrifice, or a non-prophylactic group (n = 10 that received no drops. All rabbits had Staphylococcus aureus inoculation into the cornea at 7-12 days post-implantation and were sacrificed at predetermined time-points. Prophylactic and non-prophylactic groups were compared with slit-lamp photography (SLP, anterior segment optical coherence tomography (AS-OCT, and histology, immunohistochemistry and bacterial quantification of excised corneas. Corneal vancomycin pharmacokinetics were studied in 8 additional rabbits.On day 1 post-inoculation, the median SLP score and mean±SEM AS-OCT corneal thickness (CT were greater in the non-prophylactic than the prophylactic group (11 vs. 1, p = 0.049 and 486.9±61.2 vs. 327.4±37.1 μm, p = 0.029 respectively. On days 2 and 4, SLP scores and CT were not significantly different. Immunohistochemistry showed a greater CD11b+ve/non-CD11b+ve cell ratio in the non-prophylactic group (1.45 vs. 0.71 on day 2. Bacterial counts were not significantly different between the two groups. Corneal vancomycin concentration (2.835±0.383 μg/ml exceeded minimum inhibitory concentration (MIC for Staphylococcus aureus only after 16 days of vancomycin drops. Two of 3 rabbits still developed infection despite bacterial inoculation after 16 days of prophylactic drops

  20. Exercise therapy and custom-made insoles are effective in patients with excessive pronation and chronic foot pain

    DEFF Research Database (Denmark)

    Andreasen, Jane; Mølgaard, Carsten; Christensen, Marianne

    2013-01-01

    Background: Excessive foot pronation is a causal mechanisms described in relation to injuries of the lower extremities. Evidence to support an effective treatment is insufficient. Objective: To investigate the effect of exercise and custom-made insoles to patients with excessive pronation...... and posted. Pain was measured during walking, resting and running. Static and dynamic foot postures were measured as calcaneal angle, navicular drift, drop and height. Results: The average duration of foot pain was 7.3 years. There was a significant pain reduction during walking within all groups at 4 and 12...

  1. The immediate effects of foot orthoses on functional performance in individuals with patellofemoral pain syndrome.

    Science.gov (United States)

    Barton, C J; Menz, H B; Crossley, K M

    2011-03-01

    Patellofemoral pain syndrome (PFPS) often results in reduced functional performance. There is growing evidence for the use of foot orthoses to treat this multifactorial condition. In this study, the immediate effects of foot orthoses on functional performance and the association of foot posture and footwear with improvements in function were evaluated. Fifty-two individuals with PFPS (18-35 years) were prescribed prefabricated foot orthoses (Vasyli Pro; Vasyli International, Labrador, Australia). Functional outcome measures evaluated included the change in (1) pain and (2) ease of a single-leg squat on a five-point Likert scale, and change in the number of (3) pain-free step downs and (4) single-leg rises from sitting. The association of foot posture using the Foot Posture Index, navicular drop and calcaneal angle relative to subtalar joint neutral; and the footwear motion control properties scale score with improved function were evaluated using Spearman's ρ statistics. Prefabricated foot orthoses produced significant improvements (psquat and improvements in the number of pain-free single-leg rises from sitting when wearing foot orthoses. In addition, a more pronated foot type was also found to be associated with improved ease of completing a single-leg squat when wearing foot orthoses. Prefabricated foot orthoses provide immediate improvements in functional performance, and these improvements are associated with a more pronated foot type and poorer footwear motion control properties.

  2. Anti-inflammatory and Antihistaminic Study of a Unani Eye Drop Formulation.

    Science.gov (United States)

    Abdul, Latif; Abdul, Razique; Sukul, R R; Nazish, Siddiqui

    2010-01-01

    The Unani eye drop is an ophthalmic formulation prepared for its beneficial effects in the inflammatory and allergic conditions of the eyes. In the present study, the Unani eye drop formulation was prepared and investigated for its anti-inflammatory and antihistaminic activity, using in vivo and in vitro experimental models respectively. The Unani eye drop formulation exhibited significant anti-inflammatory activity in turpentine liniment-induced ocular inflammation in rabbits. The preparation also showed antihistaminic activity in isolated guinea-pig ileum. The anti-inflammatory and antihistaminic activity of eye drop may be due to presence of active ingredients in the formulation. Although there are many drugs in Unani repository which are mentioned in classical books or used in Unani clinical practice effectively in treatment of eye diseases by various Unani physicians. Inspite of the availability of vast literature, there is a dearth of commercial Unani ocular preparations. So, keeping this in mind, the eye drop formulation was prepared and its anti-inflammatory and antihistaminic activity was carried out in animal models. Thus, in view of the importance of alternative anti-inflammatory and antiallergic drugs, it becomes imperative to bring these indigenous drugs to the front foot and evaluate their activities.

  3. Comparison of dynamic balance ability in healthy university students according to foot shape.

    Science.gov (United States)

    Hyong, In Hyouk; Kang, Jong Ho

    2016-01-01

    [Purpose] This study aimed to compare dynamic balance ability according to foot shape, defined as normal, pronated, or supinated on the basis of the height of the medial arch. [Subjects] In this study, 14 subjects for the pronated foot group, 14 for the supinated foot group, and 14 for the normal foot group were selected from among 162 healthy university students by using the navicular drop test proposed by Brody. To measure dynamic balance ability, a star excursion balance test (SEBT) was conducted for each group, in which a cross-shaped line and lines at 45° in eight directions were drawn on the floor. In this study, only three directions were used, namely anterior, posterolateral, and posteromedial. The mean of the SEBT was calculated by measuring three times for each group, and the values were standardized using the following equation: measured value/leg length × 100. [Results] No significant differences in dynamic balance ability were found between the normal, pronated, and supinated foot groups. [Conclusion] No significant differences in dynamic balance ability according to the foot shape were found among the healthy university students with normal, pronated, and supinated feet.

  4. TOTAL HIP REPLACEMENTS AT KIKUYU HOSPITAL, KENYA

    African Journals Online (AJOL)

    equipments, few trained personnel and the high cost of implants. It is mainly in the ..... function more affected than the sensory a day after. There was a foot drop. .... 60: Issue 2, 217-. 220. 13. NIH Consensus Development Panel on Total Hip.

  5. Modelling foot height and foot shape-related dimensions.

    Science.gov (United States)

    Xiong, Shuping; Goonetilleke, Ravindra S; Witana, Channa P; Lee Au, Emily Yim

    2008-08-01

    The application of foot anthropometry to design good-fitting footwear has been difficult due to the lack of generalised models. This study seeks to model foot dimensions so that the characteristic shapes of feet, especially in the midfoot region, can be understood. Fifty Hong Kong Chinese adults (26 males and 24 females) participated in this study. Their foot lengths, foot widths, ball girths and foot heights were measured and then evaluated using mathematical models. The results showed that there were no significant allometry (p > 0.05) effects of foot length on ball girth and foot width. Foot height showed no direct relationship with foot length. However, a normalisation with respect to foot length and foot height resulted in a significant relationship for both males and females with R(2) greater than 0.97. Due to the lack of a direct relationship between foot height and foot length, the current practice of grading shoes with a constant increase in height or proportionate scaling in response to foot length is less than ideal. The results when validated with other populations can be a significant way forward in the design of footwear that has an improved fit in the height dimension.

  6. Foot Drop

    Science.gov (United States)

    ... and ankle joint or that transfers tendons from stronger leg muscles is occasionally performed. × Treatment Treatment depends on the ... and ankle joint or that transfers tendons from stronger leg muscles is occasionally performed. View Full Treatment Information Definition ...

  7. Anti-inflammatory and Antihistaminic Study of a Unani Eye Drop Formulation

    Directory of Open Access Journals (Sweden)

    Latif Abdul

    2010-01-01

    Full Text Available The Unani eye drop is an ophthalmic formulation prepared for its beneficial effects in the inflammatory and allergic conditions of the eyes. In the present study, the Unani eye drop formulation was prepared and investigated for its anti-inflammatory and antihistaminic activity, using in vivo and in vitro experimental models respectively. The Unani eye drop formulation exhibited significant anti-inflammatory activity in turpentine liniment-induced ocular inflammation in rabbits. The preparation also showed antihistaminic activity in isolated guinea-pig ileum. The anti-inflammatory and antihistaminic activity of eye drop may be due to presence of active ingredients in the formulation. Although there are many drugs in Unani repository which are mentioned in classical books or used in Unani clinical practice effectively in treatment of eye diseases by various Unani physicians. Inspite of the availability of vast literature, there is a dearth of commercial Unani ocular preparations. So, keeping this in mind, the eye drop formulation was prepared and its anti-inflammatory and antihistaminic activity was carried out in animal models. Thus, in view of the importance of alternative anti-inflammatory and antiallergic drugs, it becomes imperative to bring these indigenous drugs to the front foot and evaluate their activities.

  8. Anti-inflammatory and Antihistaminic Study of a Unani Eye Drop Formulation

    Directory of Open Access Journals (Sweden)

    Latif Abdul

    2010-03-01

    Full Text Available The Unani eye drop is an ophthalmic formulation prepared for its beneficial effects in the inflammatory and allergic conditions of the eyes. In the present study, the Unani eye drop formulation was prepared and investigated for its anti-inflammatory and antihistaminic activity, using in vivo and in vitro experimental models respectively. The Unani eye drop formulation exhibited significant anti-inflammatory activity in turpentine liniment-induced ocular inflammation in rabbits. The preparation also showed antihistaminic activity in isolated guinea-pig ileum. The anti-inflammatory and antihistaminic activity of eye drop may be due to presence of active ingredients in the formulation. Although there are many drugs in Unani repository which are mentioned in classical books or used in Unani clinical practice effectively in treatment of eye diseases by various Unani physicians. Inspite of the availability of vast literature, there is a dearth of commercial Unani ocular preparations. So, keeping this in mind, the eye drop formulation was prepared and its anti-inflammatory and antihistaminic activity was carried out in animal models. Thus, in view of the importance of alternative anti-inflammatory and anti- allergic drugs, it becomes imperative to bring these indigenous drugs to the front foot and evaluate their activities.

  9. Association between hip abductor function, rear-foot dynamic alignment, and dynamic knee valgus during single-leg squats and drop landings

    Directory of Open Access Journals (Sweden)

    Yoshinori Kagaya

    2015-06-01

    Conclusion: Dynamic hip mal-alignment might be associated with both greater KID and HOD, whereas rear-foot eversion is associated only with greater KID. Hip abductor and rear-foot dysfunction are important factors for dynamic knee valgus and thus evaluating DTT and HFT will help to prevent dynamic knee valgus.

  10. Relationship between static foot posture and foot mobility

    Directory of Open Access Journals (Sweden)

    McPoil Thomas G

    2011-01-01

    Full Text Available Abstract Background It is not uncommon for a person's foot posture and/or mobility to be assessed during a clinical examination. The exact relationship, however, between static posture and mobility is not known. Objective The purpose of this study was to determine the degree of association between static foot posture and mobility. Method The static foot posture and foot mobility of 203 healthy individuals was assessed and then analyzed to determine if low arched or "pronated" feet are more mobile than high arched or "supinated" feet. Results The study demonstrated that those individuals with a lower standing dorsal arch height and/or a wider standing midfoot width had greater mobility in their foot. In addition, those individuals with higher Foot Posture Index (FPI values demonstrated greater mobility and those with lower FPI values demonstrated less mobility. Finally, the amount of foot mobility that an individual has can be predicted reasonably well using either a 3 or 4 variable linear regression model. Conclusions Because of the relationship between static foot posture and mobility, it is recommended that both be assessed as part of a comprehensive evaluation of a individual with foot problems.

  11. Analysis of 30 breast implant rupture cases.

    Science.gov (United States)

    Tark, Kwan Chul; Jeong, Hii Sun; Roh, Tae Suk; Choi, Jong Woo

    2005-01-01

    Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat

  12. Effective liquid drop description for alpha decay of atomic nuclei

    International Nuclear Information System (INIS)

    Tavares, O.A.P.; Duarte, S.B.; Rodriguez, O.; Guzman, F.; Goncalves, M.; Garcia, F.

    1998-06-01

    Alpha decay half-lives are presented in the framework of an effective liquid drop model for different combination of mass transfer descriptions and inertia coefficients. Calculated half-life-values for ground-state to ground-state favoured alpha transitions are compared with available, updated experimental data. Results have shown that the present model is very suitable to treat the alpha decay process on equal foot as cluster radioactivity and cold fission processes. Better agreement with the data is found when the sub-set of even-even alpha emitters are considered in the calculation. (author)

  13. Local Antibiotic Delivery Systems: Current and Future Applications for Diabetic Foot Infections.

    Science.gov (United States)

    Markakis, Konstantinos; Faris, Alan Robert; Sharaf, Hamed; Faris, Barzo; Rees, Sharon; Bowling, Frank L

    2018-03-01

    Foot infections are common among diabetic patients with peripheral neuropathy and/or peripheral arterial disease, and it can be the pivotal event leading to a minor or major amputation of the lower extremity. Treatment of diabetic foot infections, especially deep-seated ones, remains challenging, in part because impaired blood perfusion and the presence of biofilms can impair the effectiveness of systemic antibiotics. The local application of antibiotics is an emerging field in the treatment of diabetic foot infections, with demonstrable advantages. These include delivery of high concentrations of antibiotics in the affected area, limited systemic absorption, and thus negligible side effects. Biodegradable vehicles, such as calcium sulfate beads, are the prototypical system, providing a good elution profile and the ability to be impregnated with a variety of antibiotics. These have largely superseded the nonbiodegradable vehicles, but the strongest evidence available is for calcium bead implantation for osteomyelitis management. Natural polymers, such as collagen sponge, are an emerging class of delivery systems, although thus far, data on diabetic foot infections are limited. There is recent interest in the novel antimicrobial peptide pexiganan in the form of cream, which is active against most of the microorganisms isolated in diabetic foot infections. These are promising developments, but randomized trials are required to ascertain the efficacy of these systems and to define the indications for their use. Currently, the role of topical antibiotic agents in treating diabetic foot infections is limited and outside of routine practice.

  14. Foot morphometric phenomena.

    Science.gov (United States)

    Agić, Ante

    2007-06-01

    Knowledge of the foot morphometry is important for proper foot structure and function. Foot structure as a vital part of human body is important for many reasons. The foot anthropometric and morphology phenomena are analyzed together with hidden biomechanical descriptors in order to fully characterize foot functionality. For Croatian student population the scatter data of the individual foot variables were interpolated by multivariate statistics. Foot morphometric descriptors are influenced by many factors, such as life style, climate, and things of great importance in human society. Dominant descriptors related to fit and comfort are determined by the use 3D foot shape and advanced foot biomechanics. Some practical recommendations and conclusions for medical, sportswear and footwear practice are highlighted.

  15. Foot morphology of Turkish football players according to foot ...

    African Journals Online (AJOL)

    Football is the most popular sport in the world. Foot morphology and foot preference are important factors in football player's performance. The aim of this cross-sectional study was to evaluate the foot morphology of elite football players with different foot preferences. 407 male football players participated in this study. 328 of ...

  16. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  17. A system for gathering small mammal data

    Science.gov (United States)

    Robert D. Neely; Robert W. Campbell

    1973-01-01

    As an aid to studying vertebrate predators of the gypsy moth, a radio telemetry system was designed to detect the death of small mammals and facilitate recovery of the remains. An intraperitoneally implanted radio transmitter is triggered by the drop in body temperature when the animal dies. The device was tested in white-footed mice.

  18. Obese older adults suffer foot pain and foot-related functional limitation.

    Science.gov (United States)

    Mickle, Karen J; Steele, Julie R

    2015-10-01

    There is evidence to suggest being overweight or obese places adults at greater risk of developing foot complications such as osteoarthritis, tendonitis and plantar fasciitis. However, no research has comprehensively examined the effects of overweight or obesity on the feet of individuals older than 60 years of age. Therefore we investigated whether foot pain, foot structure, and/or foot function is affected by obesity in older adults. Three hundred and twelve Australian men and women, aged over 60 years, completed validated questionnaires to establish the presence of foot pain and health related quality of life. Foot structure (anthropometrics and soft tissue thickness) and foot function (ankle dorsiflexion strength and flexibility, toe flexor strength, plantar pressures and spatiotemporal gait parameters) were also measured. Obese participants (BMI >30) were compared to those who were overweight (BMI=25-30) and not overweight (BMI foot pain and scored significantly lower on the SF-36. Obesity was also associated with foot-related functional limitation whereby ankle dorsiflexion strength, hallux and lesser toe strength, stride/step length and walking speed were significantly reduced in obese participants compared to their leaner counterparts. Therefore, disabling foot pain and altered foot structure and foot function are consequences of obesity for older adults, and impact upon their quality of life. Interventions designed to reduce excess fat mass may relieve loading of the foot structures and, in turn, improve foot pain and quality of life for older obese individuals. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Madura foot: two case reports, review of the literature, and new developments with clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    White, Eric A. [University of Southern California, Department of Radiology, Los Angeles, CA (United States); Patel, Dakshesh B.; Forrester, Deborah M.; Gottsegen, Christopher J.; O' Rourke, Emily; Holtom, Paul; Charlton, Timothy; Matcuk, George R. [USC University Hospital, Los Angeles, CA (United States)

    2014-04-15

    ''Madura foot'' or pedal mycetoma is a rare destructive infection of the skin and subcutaneous tissues of the foot, progressing to involve muscle and bone. The infection can be caused by both bacteria and fungi. Infection typically follows traumatic implantation of bacteria or fungal spores, which are present in soil or on plant material. Clinically, this entity can be difficult to diagnose and can have an indolent and progressive course. Early diagnosis is important to prevent patient morbidity and mortality. We present two cases of pedal mycetoma, review the literature, review new developments in diagnosis, and discuss magnetic resonance imaging (MRI) features of this unusual entity. (orig.)

  20. Foot Health

    Science.gov (United States)

    ... straight across and not too short Your foot health can be a clue to your overall health. For example, joint stiffness could mean arthritis. Tingling ... foot checks are an important part of your health care. If you have foot problems, be sure ...

  1. The dimensions of the tarsal sinus and canal in different foot positions and its clinical implications

    NARCIS (Netherlands)

    Kleipool, R. P.; Blankevoort, L.; Ruijter, J. M.; Kerkhoffs, G. M. M. J.; Oostra, R. J.

    2017-01-01

    This study presents a reference for the dimensions of the tarsal sinus and canal in healthy adults in different foot positions to facilitate understanding of the kinematics of the subtalar joint, the effect of an implant, and other clinical issues. In a 3D CT stress test on 20 subjects, the right

  2. Ion implantation - a useful tool for the preparation of new materials

    International Nuclear Information System (INIS)

    Buckel, W.

    1975-01-01

    The following experimental results on ion implantation in superconductors are discussed: 1) Implantation of paramagnetic manganese ions into the superconductors Sn, Pb, Hg lowers the transition temperature. 2) Sn implanted with Mn exhibits the Kondo effect, a minimum in the resistivity versus temperature immediately above Tsub(c). 3) Pd may become superconducting, when charged with H at ratios H/Pd > 0.8. Tsub(c) first increases with concentration and then drops again. The increase in Tsub(c) is still larger for Pd-noble metal alloys charged with H(D). (WBU) [de

  3. Dynamic and quasi-static simulation and analysis of the plutonium oxide/metal containers subject to 30-foot dropping

    International Nuclear Information System (INIS)

    Gong, C.; Miller, R.F.

    1995-01-01

    This analysis of the plutonium oxide/metal storage containers is in support of the design and testing project The results from the dynamic analysis show some important facts that have not been considered before. The internal bagless transfer can will have higher stress than the primary container. The quasi-static analysis provides a conservative solution. In both vertical upright drop (dynamic) and inclined upside down drop (quasi-static) the containers are structurally sound

  4. Effective liquid drop description for alpha decay of atomic nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, O.A.P.; Duarte, S.B. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Rodriguez, O.; Guzman, F. [Instituto Superior de Ciencia y Tecnologia Nuclear (ISCTN), La Habana (Cuba); Goncalves, M. [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil); Garcia, F. [Sao Paulo Univ., SP (Brazil). Inst. de Fisica

    1998-06-01

    Alpha decay half-lives are presented in the framework of an effective liquid drop model for different combination of mass transfer descriptions and inertia coefficients. Calculated half-life-values for ground-state to ground-state favoured alpha transitions are compared with available, updated experimental data. Results have shown that the present model is very suitable to treat the alpha decay process on equal foot as cluster radioactivity and cold fission processes. Better agreement with the data is found when the sub-set of even-even alpha emitters are considered in the calculation. (author) 44 refs., 5 figs., 3 tabs.; e-mail: telo at ird.gov.br

  5. Significant improvement of the osseointegration of zirconia dental implants by HS-LEIS analysis

    International Nuclear Information System (INIS)

    Beekmans, H.; Breitenstein, D.; Brongersma, H.H.; Ridder, M. de; Tromp, Th.J.

    2010-01-01

    The use of sintered yttria stabilized zirconia dental implants is a recent development. After initial successes with these new implants a pattern of erratic results emerged. Reliable osseointegration would not always occur. High-sensitivity low energy ion scattering (HS-LEIS) is used to investigate both virgin and rejected implants. The surfaces of the implant are found to be covered with both an organic and inorganic contamination layer. Sterilization does not remove this contamination. Using LEIS as analytic tool a new cleaning process has been developed. Since this cleaning process is in use, the failure rate has dropped to a very low value.

  6. The effect of a knee ankle foot orthosis incorporating an active knee mechanism on gait of a person with poliomyelitis.

    Science.gov (United States)

    Arazpour, Mokhtar; Chitsazan, Ahmad; Bani, Monireh Ahmadi; Rouhi, Gholamreza; Ghomshe, Farhad Tabatabai; Hutchins, Stephen W

    2013-10-01

    The aim of this case study was to identify the effect of a powered stance control knee ankle foot orthosis on the kinematics and temporospatial parameters of walking by a person with poliomyelitis when compared to a knee ankle foot orthosis. A knee ankle foot orthosis was initially manufactured by incorporating drop lock knee joints and custom molded ankle foot orthoses and fitted to a person with poliomyelitis. The orthosis was then adapted by adding electrically activated powered knee joints to provide knee extension torque during stance and also flexion torque in swing phase. Lower limb kinematic and kinetic data plus data for temporospatial parameters were acquired from three test walks using each orthosis. Walking speed, step length, and vertical and horizontal displacement of the pelvis decreased when walking with the powered stance control knee ankle foot orthosis compared to the knee ankle foot orthosis. When using the powered stance control knee ankle foot orthosis, the knee flexion achieved during swing and also the overall pattern of walking more closely matched that of normal human walking. The reduced walking speed may have caused the smaller compensatory motions detected when the powered stance control knee ankle foot orthosis was used. The new powered SCKAFO facilitated controlled knee flexion and extension during ambulation for a volunteer poliomyelitis person.

  7. Effects of ankle-foot orthoses on mediolateral foot-placement ability during post-stroke gait.

    Science.gov (United States)

    Zissimopoulos, Angelika; Fatone, Stefania; Gard, Steven

    2015-10-01

    Accurate and precise mediolateral foot placement is important for balance during gait, but is impaired post stroke. Mediolateral foot placement may be improved with ankle-foot orthosis use. The purpose of this study was to determine whether an ankle-foot orthosis improves mediolateral foot-placement ability during post-stroke ambulation. Crossover trial with randomized order of conditions tested. The accuracy and precision of mediolateral foot placement was quantified while subjects targeted four different randomized step widths. Subjects were tested with and without their regular non-rigid ankle-foot orthosis in two separate visits (order randomized). While ankle-foot orthosis use corrected foot and ankle alignment (i.e. significantly decreased mid-swing plantar flexion, p = 0.000), effects of ankle-foot orthosis use on hip hiking (p = 0.545), circumduction (p = 0.179), coronal plane hip range of motion (p = 0.06), and mediolateral foot-placement ability (p = 0.537) were not significant. While ankle-foot orthosis-mediated equinovarus correction of the affected foot and ankle was not associated with improved biomechanics of walking (i.e. proximal ipsilateral hip kinematics or mediolateral foot-placement ability), it may affect other aspects of balance that were not tested in this study (e.g. proprioception, cerebellar, vestibular, and cognitive mechanisms). Studies that investigate the effect of ankle-foot orthosis on gait can help advance stroke rehabilitation by documenting the specific gait benefits of ankle-foot orthosis use. In this study, we investigated the effect of ankle-foot orthosis use on mediolateral foot-placement ability, an aspect of gait important for maintaining balance. © The International Society for Prosthetics and Orthotics 2014.

  8. Foot roll-over evaluation based on 3D dynamic foot scan.

    Science.gov (United States)

    Samson, William; Van Hamme, Angèle; Sanchez, Stéphane; Chèze, Laurence; Van Sint Jan, Serge; Feipel, Véronique

    2014-01-01

    Foot roll-over is commonly analyzed to evaluate gait pathologies. The current study utilized a dynamic foot scanner (DFS) to analyze foot roll-over. The right feet of ten healthy subjects were assessed during gait trials with a DFS system integrated into a walkway. A foot sole picture was computed by vertically projecting points from the 3D foot shape which were lower than a threshold height of 15 mm. A 'height' value of these projected points was determined; corresponding to the initial vertical coordinates prior to projection. Similar to pedobarographic analysis, the foot sole picture was segmented into anatomical regions of interest (ROIs) to process mean height (average of height data by ROI) and projected surface (area of the projected foot sole by ROI). Results showed that these variables evolved differently to plantar pressure data previously reported in the literature, mainly due to the specificity of each physical quantity (millimeters vs Pascals). Compared to plantar pressure data arising from surface contact by the foot, the current method takes into account the whole plantar aspect of the foot, including the parts that do not make contact with the support surface. The current approach using height data could contribute to a better understanding of specific aspects of foot motion during walking, such as plantar arch height and the windlass mechanism. Results of this study show the underlying method is reliable. Further investigation is required to validate the DFS measurements within a clinical context, prior to implementation into clinical practice. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Contributions of foot muscles and plantar fascia morphology to foot posture.

    Science.gov (United States)

    Angin, Salih; Mickle, Karen J; Nester, Christopher J

    2018-03-01

    The plantar foot muscles and plantar fascia differ between different foot postures. However, how each individual plantar structure contribute to foot posture has not been explored. The purpose of this study was to investigate the associations between static foot posture and morphology of plantar foot muscles and plantar fascia and thus the contributions of these structures to static foot posture. A total of 111 participants were recruited, 43 were classified as having pes planus and 68 as having normal foot posture using Foot Posture Index assessment tool. Images from the flexor digitorum longus (FDL), flexor hallucis longus (FHL), peroneus longus and brevis (PER), flexor hallucis brevis (FHB), flexor digitorum brevis (FDB) and abductor hallucis (AbH) muscles, and the calcaneal (PF1), middle (PF2) and metatarsal (PF3) regions of the plantar fascia were obtained using a Venue 40 ultrasound system with a 5-13 MHz transducer. In order of decreasing contribution, PF3 > FHB > FHL > PER > FDB were all associated with FPI and able to explain 69% of the change in FPI scores. PF3 was the highest contributor explaining 52% of increases in FPI score. Decreased thickness was associated with increased FPI score. Smaller cross sectional area (CSA) in FHB and PER muscles explained 20% and 8% of increase in FPI score. Larger CSA of FDB and FHL muscles explained 4% and 14% increase in FPI score respectively. The medial plantar structures and the plantar fascia appear to be the major contributors to static foot posture. Elucidating the individual contribution of multiple muscles of the foot could provide insight about their role in the foot posture. Copyright © 2018. Published by Elsevier B.V.

  10. The effect of low-Dye taping on plantar pressures, during gait, in subjects with navicular drop exceeding 10 mm.

    Science.gov (United States)

    Lange, Belinda; Chipchase, Lucy; Evans, Angela

    2004-04-01

    A preintervention and postintervention, repeated-measures experimental design. To investigate the immediate effect of low-Dye taping on peak and mean plantar pressures during gait in subjects with navicular drop exceeding 10 mm. Low-Dye taping is commonly used to support the longitudinal and transverse arches of the foot in an attempt to reduce the effects of symptoms associated with excessive pronation. Plantar pressure measurement has been used as an indirect indicator of pronation during gait. METHOD AND MEASURES: The right foot of 60 subjects was tested using the Emed-AT system to obtain plantar pressure values. Subjects performed 6 barefoot walks over the Emed pressure platform while taped and a further 6 walks while untaped. Plantar pressures were recorded. Each footprint obtained was divided into 10 sections or 'masks.' Average peak and mean plantar pressure values (N/cm2) were calculated for both taped and untaped walks for each mask. Paired t tests demonstrated significant changes in peak plantar pressure in 8 of the 10 areas of the foot and significant changes in mean plantar pressure in 9 of the 10 areas of the foot. Low-Dye taping significantly decreased pressure under the heel and the medial and middle forefoot, while increasing pressure under the lateral midfoot and under the toes. A significant decrease in mean plantar pressure was observed under the lateral forefoot, while no significant difference was demonstrated in peak plantar pressure under this area. The area under the medial midfoot demonstrated no significant change in either peak or mean pressure. Low-Dye taping significantly altered peak and mean plantar pressure values in subjects with navicular drop exceeding 10 mm. In particular, peak and mean plantar pressure increased under the lateral midfoot and under the toes, and decreased under the heel and forefoot, suggesting that a decrease in the amount of pronation occurred.

  11. [Foot growth and foot types in children and adolescents: a narrative review].

    Science.gov (United States)

    Xu, Miaomiao; Wang, Lin

    2017-08-01

    Foot shape and size are important for footwear design and production. Information about important foot characteristics helps not only to improve shoe comfort but to maintain the proper physiological development of the feet. What's more, plenty of studies have suggested that the shape of the shoe must closely resemble the shape of the foot to create a properly fitted shoe. This means that the differences between various populations should be considered and that footwear should be designed according to the measurements of users. Childhood and adolescent are important periods of human growth. During these periods, foot shape changes with human growth and can be influenced by extrinsic factors. Therefore, the foot shape characteristics of children and adolescents should be investigated. The results from these investigations can contribute to developing appropriate shoe for children and adolescents, improving perceived comfort of children shoes and preventing pedopathy among children and adolescents. This review aims to discuss measuring methods of foot shape, types of foot shape, and factors influencing foot shape. The results of the review can provide recommendations for investigating growth development of foot shape and useful information for consumers and shoe manufacturers.

  12. Monitoring failure rates of commercial implant brands; substantial equivalence in question?

    Science.gov (United States)

    Hujoel, Philippe; Becker, William; Becker, Burton

    2013-07-01

    The aim of this study was to report on the failure rates of two distinct dental implant systems in a clinical practice setting. Date of implant placement and loss were entered prospectively in a data registry system. Failure rates of two commercially pure titanium implants, one with a porous oxydized surface (POS) and the other with a chemically altered surface (CAS), were assessed using a quality control chart and survival analyses. A total of 860 POS and 759 CAS implants were placed. A warning of an increased failure rate of the CAS implant was identified by means of the quality control chart. Survival analyses indicated that the CAS implant failure rate was twice that of the POS implant (Hazard Ratio: 2.08; 95% CI: 1.33-3.28, P-value POS implant was associated with a non-significant 64% drop in the implant failure rate within less than a year (HR: 0.36; 95% CI: 0.12-1.14; P-value POS implant and an 8% failure with the CAS implant appears inconsistent with the assumption of substantial equivalence. © 2012 John Wiley & Sons A/S.

  13. Characterizing multisegment foot kinematics during gait in diabetic foot patients

    Directory of Open Access Journals (Sweden)

    Denti Paolo

    2009-10-01

    Full Text Available Abstract Background The prevalence of diabetes mellitus has reached epidemic proportions, this condition may result in multiple and chronic invalidating long term complications. Among these, the diabetic foot, is determined by the simultaneous presence of both peripheral neuropathy and vasculopathy that alter the biomechanics of the foot with the formation of callosity and ulcerations. To diagnose and treat the diabetic foot is crucial to understand the foot complex kinematics. Most of gait analysis protocols represent the entire foot as a rigid body connected to the shank. Nevertheless the existing multisegment models cannot completely decipher the impairments associated with the diabetic foot. Methods A four segment foot and ankle model for assessing the kinematics of the diabetic foot was developed. Ten normal subjects and 10 diabetics gait patterns were collected and major sources of variability were tested. Repeatability analysis was performed both on a normal and on a diabetic subject. Direct skin marker placement was chosen in correspondence of 13 anatomical landmarks and an optoelectronic system was used to collect the data. Results Joint rotation normative bands (mean plus/minus one standard deviation were generated using the data of the control group. Three representative strides per subject were selected. The repeatability analysis on normal and pathological subjects results have been compared with literature and found comparable. Normal and pathological gait have been compared and showed major statistically significant differences in the forefoot and midfoot dorsi-plantarflexion. Conclusion Even though various biomechanical models have been developed so far to study the properties and behaviour of the foot, the present study focuses on developing a methodology for the functional assessment of the foot-ankle complex and for the definition of a functional model of the diabetic neuropathic foot. It is, of course, important to evaluate

  14. Relationship between Leg Mass, Leg Composition and Foot Velocity on Kicking Accuracy in Australian Football

    Directory of Open Access Journals (Sweden)

    Nicolas H. Hart, Jodie L. Cochrane, Tania Spiteri, Sophia Nimphius, Robert U. Newton

    2016-06-01

    Full Text Available Kicking a ball accurately over a desired distance to an intended target is arguably the most important skill to acquire in Australian Football. Therefore, understanding the potential mechanisms which underpin kicking accuracy is warranted. The aim of this study was to examine the relationship between leg mass, leg composition and foot velocity on kicking accuracy in Australian Football. Thirty-one Australian Footballers (n = 31; age: 22.1 ± 2.8 years; height: 1.81 ± 0.07 m; weight: 85.1 ± 13.0 kg; BMI: 25.9 ± 3.2 each performed ten drop punt kicks over twenty metres to a player target. Athletes were separated into accurate (n = 15 and inaccurate (n = 16 kicking groups. Leg mass characteristics were assessed using whole body DXA scans. Foot velocity was determined using a ten-camera optoelectronic, three-dimensional motion capture system. Interactions between leg mass and foot velocity evident within accurate kickers only (r = -0.670 to -0.701. Relative lean mass was positively correlated with kicking accuracy (r = 0.631, while no relationship between foot velocity and kicking accuracy was evident in isolation (r = -0.047 to -0.083. Given the evident importance of lean mass, and its interaction with foot velocity for accurate kickers; future research should explore speed-accuracy, impulse-variability, limb co-ordination and foot-ball interaction constructs in kicking using controlled with-in subject studies to examine the effects of resistance training and skill acquisition programs on the development of kicking accuracy.

  15. Drop jumping. II. The influence of dropping height on the biomechanics of drop jumping

    NARCIS (Netherlands)

    Bobbert, M F; Huijing, P A; van Ingen Schenau, G J

    In the literature, athletes preparing for explosive activities are recommended to include drop jumping in their training programs. For the execution of drop jumps, different techniques and different dropping heights can be used. This study was designed to investigate for the performance of bounce

  16. First drop dissimilarity in drop-on-demand inkjet devices

    International Nuclear Information System (INIS)

    Famili, Amin; Palkar, Saurabh A.; Baldy, William J. Jr.

    2011-01-01

    As inkjet printing technology is increasingly applied in a broader array of applications, careful characterization of its method of use is critical due to its inherent sensitivity. A common operational mode in inkjet technology known as drop-on-demand ejection is used as a way to deliver a controlled quantity of material to a precise location on a target. This method of operation allows ejection of individual or a sequence (burst) of drops based on a timed trigger event. This work presents an examination of sequences of drops as they are ejected, indicating a number of phenomena that must be considered when designing a drop-on-demand inkjet system. These phenomena appear to be driven by differences between the first ejected drop in a burst and those that follow it and result in a break-down of the linear relationship expected between driving amplitude and drop mass. This first drop, as quantified by high-speed videography and subsequent image analysis, can be different in morphology, trajectory, velocity, and volume from subsequent drops within a burst. These findings were confirmed orthogonally by both volume and mass measurement techniques which allowed quantitation down to single drops.

  17. Fixation Strength of Polyetheretherketone Sheath-and-Bullet Device for Soft Tissue Repair in the Foot and Ankle.

    Science.gov (United States)

    Christensen, Jay; Fischer, Brian; Nute, Michael; Rizza, Robert

    Tendon transfers are often performed in the foot and ankle. Recently, interference screws have been a popular choice owing to their ease of use and fixation strength. Considering the benefits, one disadvantage of such devices is laceration of the soft tissues by the implant threads during placement that potentially weaken the structural integrity of the grafts. A shape memory polyetheretherketone bullet-in-sheath tenodesis device uses circumferential compression, eliminating potential damage from thread rotation and maintaining the soft tissue orientation of the graft. The aim of this study was to determine the pullout strength and failure mode for this device in both a synthetic bone analogue and porcine bone models. Thirteen mature bovine extensor tendons were secured into ten 4.0 × 4.0 × 4.0-cm cubes of 15-pound per cubic foot solid rigid polyurethane foam bone analogue models or 3 porcine femoral condyles using the 5 × 20-mm polyetheretherketone soft tissue anchor. The bullet-in-sheath device demonstrated a mean pullout of 280.84 N in the bone analog models and 419.47 N in the porcine bone models. (p = .001). The bullet-in-sheath design preserved the integrity of the tendon graft, and none of the implants dislodged from their original position. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Repeatability of the Oxford Foot Model in children with foot deformity

    NARCIS (Netherlands)

    McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim

    Introduction The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in

  19. WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Racine, E [Departement de Radio-Oncologie et Centre de Recherche du CHU de Quebec, Quebec, QC (Canada); Hautvast, G [Biomedical Systems, Philips Group Innovation, Eindhoven, North Brabant (Netherlands); Binnekamp, D [Integrated Clinical Solutions and Marketing, Philips Healthcare, Best, DA (Netherlands); Beaulieu, L [Centre Hospitalier University de Quebec, Quebec, QC (Canada)

    2014-06-15

    Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry

  20. WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

    International Nuclear Information System (INIS)

    Racine, E; Hautvast, G; Binnekamp, D; Beaulieu, L

    2014-01-01

    Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry

  1. Is the foot elevation the optimal position for wound healing of a diabetic foot?

    Science.gov (United States)

    Park, D J; Han, S K; Kim, W K

    2010-03-01

    In managing diabetic foot ulcers, foot elevation has generally been recommended to reduce oedema and prevent other sequential problems. However, foot elevation may decrease tissue oxygenation of the foot more than the dependent position since the dependent position is known to increase blood flow within the arterial system. In addition, diabetic foot ulcers, which have peripheral vascular insufficiency, generally have less oedema than other wounds. Therefore, we argue that foot elevation may not be helpful for healing of vascularly compromised diabetic foot ulcers since adequate tissue oxygenation is an essential factor in diabetic wound healing. The purpose of this study was to evaluate the influence of foot height on tissue oxygenation and to determine the optimal foot position to accelerate wound healing of diabetic foot ulcers. This study included 122 cases (73 males and 47 females; two males had bilateral disease) of diabetic foot ulcer patients aged 40-93 years. Trans-cutaneous partial oxygen tension (TcpO(2)) values of diabetic feet were measured before and after foot elevation (n=21). Elevation was achieved by placing a foot over four cushions. We also measured foot TcpO(2) values before and after lowering the feet (n=122). Feet were lowered to the patient's tibial height, approximately 30-35 cm, beside a bed handrail. Due to the large number of lowering measurements, we divided them into five sub-groups according to initial TcpO(2.) Tissue oxygenation values were compared. Foot-elevation-lowered TcpO(2) values before and after elevation were 32.5+/-22.2 and 23.8+/-23.1 mmHg (pFoot-lowering-augmented TcpO(2) values before and after lowering were 44.6+/-23.8 and 58.0+/-25.9 mmHg (pfoot lowering, rather than elevation, significantly augments TcpO(2) and may stimulate healing of diabetic foot ulcers. (c) 2008 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Establishing contact between cell-laden hydrogels and metallic implants with a biomimetic adhesive for cell therapy supported implants.

    Science.gov (United States)

    Barthes, Julien; Mutschler, Angela; Dollinger, Camille; Gaudinat, Guillaume; Lavalle, Philippe; Le Houerou, Vincent; Brian McGuinness, Garrett; Engin Vrana, Nihal

    2017-12-15

    For in-dwelling implants, controlling the biological interface is a crucial parameter to promote tissue integration and prevent implant failure. For this purpose, one possibility is to facilitate the establishment of the interface with cell-laden hydrogels fixed to the implant. However, for proper functioning, the stability of the hydrogel on the implant should be ensured. Modification of implant surfaces with an adhesive represents a promising strategy to promote the adhesion of a cell-laden hydrogel on an implant. Herein, we developed a peptidic adhesive based on mussel foot protein (L-DOPA-L-lysine) 2 -L-DOPA that can be applied directly on the surface of an implant. At physiological pH, unoxidized (L-DOPA-L-lysine) 2 -L-DOPA was supposed to strongly adhere to metallic surfaces but it only formed a very thin coating (less than 1 nm). Once oxidized at physiological pH, (L-DOPA-L-lysine) 2 -L-DOPA forms an adhesive coating about 20 nm thick. In oxidized conditions, L-lysine can adhere to metallic substrates via electrostatic interaction. Oxidized L-DOPA allows the formation of a coating through self-polymerization and can react with amines so that this adhesive can be used to fix extra-cellular matrix based materials on implant surfaces through the reaction of quinones with amino groups. Hence, a stable interface between a soft gelatin hydrogel and metallic surfaces was achieved and the strength of adhesion was investigated. We have shown that the adhesive is non-cytotoxic to encapsulated cells and enabled the adhesion of gelatin soft hydrogels for 21 days on metallic substrates in liquid conditions. The adhesion properties of this anchoring peptide was quantified by a 180° peeling test with a more than 60% increase in peel strength in the presence of the adhesive. We demonstrated that by using a biomimetic adhesive, for the application of cell-laden hydrogels to metallic implant surfaces, the hydrogel/implant interface can be ensured without relying on the

  3. Treatment of first metatarsophalangeal joint arthritis using hemiarthroplasty with a synthetic cartilage implant or arthrodesis: A comparison of operative and recovery time.

    Science.gov (United States)

    Glazebrook, Mark; Younger, Alastair S E; Daniels, Timothy R; Singh, Dishan; Blundell, Chris; de Vries, Gwyneth; Le, Ian L D; Nielsen, Dominic; Pedersen, M Elizabeth; Sakellariou, Anthony; Solan, Matthew; Wansbrough, Guy; Baumhauer, Judith F

    2017-05-29

    First metatarsophalangeal joint (MTPJ1) hemiarthroplasty using a novel synthetic cartilage implant was as effective and safe as MTPJ1 arthrodesis in a randomized clinical trial. We retrospectively evaluated operative time and recovery period for implant hemiarthroplasty (n=152) and MTPJ1 arthrodesis (n=50). Perioperative data were assessed for operative and anaesthesia times. Recovery and return to function were prospectively assessed with the Foot and Ankle Ability Measure (FAAM) Sports and Activities of Daily Living (ADL) subscales and SF-36 Physical Functioning (PF) subscore. Mean operative time for hemiarthroplasty was 35±12.3min and 58±21.5min for arthrodesis (pSport, FAAM ADL, and SF-36 PF subscores versus arthrodesis patients. MTPJ1 hemiarthroplasty with a synthetic cartilage implant took less operative time and resulted in faster recovery than arthrodesis. III, Retrospective case control study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  4. Connective tissue grafts for thickening peri-implant tissues at implant placement. One-year results from an explanatory split-mouth randomised controlled clinical trial.

    Science.gov (United States)

    Wiesner, Günter; Esposito, Marco; Worthington, Helen; Schlee, Markus

    2010-01-01

    Nothing to declare. To evaluate whether connective tissue grafts performed at implant placement could be effective in augmenting peri-implant soft tissues. Ten partially edentulous patients requiring at least one single implant in the premolar or molar areas of both sides of the mandible were randomised to have one side augmented at implant placement with a connective soft tissue graft harvested from the palate or no augmentation. After 3 months of submerged healing, abutments were placed and within 1 month definitive crowns were permanently cemented. Outcome measures were implant success, any complications, peri-implant marginal bone level changes, patient satisfaction and preference, thickness of the soft tissues and aesthetics (pink aesthetic score) evaluated by an independent and blinded assessor 1 year after loading. One year after loading, no patients dropped out, no implants failed and no complications occurred. Both groups lost statistically significant amounts of peri-implant bone 1 year after loading (0.8 mm in the grafted group and 0.6 mm in the non-grafted group), but there was no statistically significant difference between groups. Soft tissues at augmented sites were 1.3 mm thicker (P Connective tissue grafts are effective in increasing soft tissue thickness, thus improving aesthetics. Longer follow-ups are needed to evaluate the stability of peri-implant tissues over time.

  5. Charcot Foot

    Science.gov (United States)

    ... damage (neuropathy). The bones are weakened enough to fracture, and with continued walking, the foot eventually changes ... difference. Advanced therapies for foot wounds are saving limbs, restoring ... in the feet come from the lower back. Pressure or chemical change in the nerve ...

  6. Severe pain as a possible cause of dropped head syndrome that was attenuated after amputation of an ischemic lower limb.

    Science.gov (United States)

    Maki, Satoshi; Koda, Masao; Furuya, Takeo; Takahashi, Kazuhisa; Yamazaki, Masashi

    2016-03-02

    Dropped head syndrome (DHS) is defined as weakness of the neck extensor muscles causing a correctable chin-on-the-chest deformity. Here we report the case of a patient with severe pain from lower leg ischemia showing DHS whose symptoms were attenuated by pain relief after amputation of the severely ischemic lower leg. To our knowledge this is the first report indicating that severe pain can cause DHS. A 64-year-old Asian woman was referred to our department with a 1-month history of DHS. She also suffered from severe right foot pain because of limb ischemia. She began to complain of DHS as her gangrenous foot pain worsened. She had neck pain and difficulty with forward gaze. We found no clinical or laboratory findings of neuromuscular disorder or isolated neck extensor myopathy. We amputated her leg below the knee because of progressive foot gangrene. Her severe foot pain resolved after the surgery and her DHS was attenuated. Severe pain can cause DHS. If a patient with DHS has severe pain in another part of the body, we recommend considering aggressive pain relief as a treatment option.

  7. Natural gaits of the non-pathological flat foot and high-arched foot

    OpenAIRE

    Fan, Yifang; Fan, Yubo; Li, Zhiyu; Lv, Changsheng; Luo, Donglin

    2010-01-01

    There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static footprints from subjects adopting a half-weight-bearing stance. Based upon their footprints, the subjects were divided into two groups: the flat-footed and the high-arched. The plantar pressure measurement system was used to measure and record the subjects' successive natural gaits. Two indic...

  8. Evaluation of an implant to synchronize oestrus and/or to resolve suckling anoestrus in Brahman cows

    International Nuclear Information System (INIS)

    Olivera, M.; Martinez, G.

    1990-01-01

    A study was conducted to evaluate the effect of a commercial progesterone implant in inducing oestrus and subsequent fertility (conception rate) in 63 adult Brahman cows with 3-5 month old calves at foot. Half the acyclic cows came into heat as a result of the implant; however, only 29% of these became pregnant after first insemination. The poor conception rate agrees with the results of other studies where progesterone treated cattle were found to be less fertile than those cycling spontaneously. (author). 13 refs, 1 tab

  9. Foot placement modulation diminishes for perturbations near foot contact

    NARCIS (Netherlands)

    Vlutters, Mark; Van Asseldonk, Edwin H.F.; van der Kooij, Herman

    2018-01-01

    Whenever a perturbation occurs during walking we have to maintain our balance using the recovery strategies that are available to us. Foot placement adjustment is often considered an important recovery strategy. However, because this strategy takes time it is likely a poor option if the foot is

  10. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    Science.gov (United States)

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  11. Drop Impact Dynamics with Sessile Drops and Geometries: Spreading, Jetting, and Fragmentation

    Science.gov (United States)

    Tilger, Christopher F.

    The tendency of surface tension to cause small parcels of fluid to form into drops allows convenient packaging, transport, dispersal of liquid phase matter. Liquid drop impacts with solids, liquids, and other drops have realized and additional future applications in biological, manufacturing, heat transfer, and combustion systems. Experiments were conducted to investigate the dynamics of multiple drop collisions, rather than the most-studied phenomenon of single drop impacts. Additional drop impacts were performed on rigid hemispheres representing sessile drops, angled substrates, and into the vertex of two tilted surfaces arranged into a vee shape. A qualitative inspection of drop-sessile drop impacts shows distinct post-impact shapes depending on the offset distance between the drops. At intermediate offset distances, distinct jets issue from the overlap region between the two drops projected areas. These jets are observed to reach their maximum extent at a critical offset distance ratio, epsilon epsilon ˜ 0.75-0.80, with substrate contact angle and W e having a lesser effect. Capillary waves that traverse the sessile drop after collision cause a lower aspect ratio liquid column to emanate from the sessile drop opposite the impact. In order to better understand the jetting phenomenon seen in the offset drop-sessile drop impacts, simpler solid geometries are investigated that elicit a similar behavior. Solid hemispheres do not show the singular jetting observed in the fluidic case, however, a simple vee formed by two intersection planar substrates do jet in a similar fashion to the fluidic case. A geometric model with partnered experiments is developed to describe the bisymmetric spread of an impacting drop on an angled substrate. This geometric model is used to guide a time of arrival based model for various features of the drop impact, which is used to predict jetting in various vee channel experiments.

  12. Impact reduction through long-term intervention in recreational runners: midfoot strike pattern versus low-drop/low-heel height footwear.

    Science.gov (United States)

    Giandolini, Marlène; Horvais, Nicolas; Farges, Yohann; Samozino, Pierre; Morin, Jean-Benoît

    2013-08-01

    Impact reduction has become a factor of interest in the prevention of running-related injuries such as stress fractures. Currently, the midfoot strike pattern (MFS) is thought as a potential way to decrease impact. The purpose was to test the effects of two long-term interventions aiming to reduce impact during running via a transition to an MFS: a foot strike retraining versus a low-drop/low-heel height footwear. Thirty rearfoot strikers were randomly assigned to two experimental groups (SHOES and TRAIN). SHOES progressively wore low-drop/low-heel height shoes and TRAIN progressively adopted an MFS, over a 3-month period with three 30-min running sessions per week. Measurement sessions (pre-training, 1, 2 and 3 months) were performed during which subjects were equipped with three accelerometers on the shin, heel and metatarsals, and ran for 15 min on an instrumented treadmill. Synchronized acceleration and vertical ground reaction force signals were recorded. Peak heel acceleration was significantly lower as compared to pre-training for SHOES (-33.5 ± 12.8 % at 2 months and -25.3 ± 18.8 % at 3 months, p heel height footwear seemed to be more effective than foot strike retraining to attenuate heel impact in the long term.

  13. Clinical application of single-tooth replacement with ankylos implant system

    International Nuclear Information System (INIS)

    Yang Xu; Liu Xue; Zhang Heng; Deng Yan; Guo Zhaozhong; Zhang Yufeng

    2011-01-01

    Objective: To evaluate the clinical effects of Ankylos implant system to restore the loss of single-tooth. Methods: 90 cases with loss of single-tooth were selected and treated with routinely two-stage surgery. When the patients presented with deficient alveolar ridge, guided bone regeneration (GBR), osteotome sinus floor elevation, lateral antrostomy surgery with simultaneous placement of implant were applied. They were restored with platinum ceramic crown. All the implants were followed up, and the records were kept about stability of the implant and abutment, the status of surrounding soft tissue, sealability of implant abutment junction and the marginal bone lossing through X-ray checking,and satisfaction of the patients to mastication and aspect of the restorations. The follow-up time was 1-2.5 years. Results: Among the cases,one case had peri-implant inflammation, and one case had porcelain dropped. No loosening occurred in the other implants and abuments. Implant abutment junction was sealed well. The marginal bone loss 1 year after final restoration was less than 1 mm. Soft tissue surrounding implants was healthy. The satisfaction rate was 98.9% (89/90). According to standard of implant success, 88 cases were successful, the 2.5-year cumulative success rate was 97.8%, 2 cases failed, and the failure rate was 2.2 %. Conclusion: A satisfactory treatment effects could be gotten by using Ankylos implant system to restore the loss of single-tooth. (authors)

  14. Generation of subject-specific, dynamic, multisegment ankle and foot models to improve orthotic design: a feasibility study

    Directory of Open Access Journals (Sweden)

    Oosterwaal Michiel

    2011-11-01

    Full Text Available Abstract Background Currently, custom foot and ankle orthosis prescription and design tend to be based on traditional techniques, which can result in devices which vary greatly between clinicians and repeat prescription. The use of computational models of the foot may give further insight in the biomechanical effects of these devices and allow a more standardised approach to be taken to their design, however due to the complexity of the foot the models must be highly detailed and dynamic. Methods/Design Functional and anatomical datasets will be collected in a multicentre study from 10 healthy participants and 15 patients requiring orthotic devices. The patient group will include individuals with metarsalgia, flexible flat foot and drop foot. Each participant will undergo a clinical foot function assessment, 3D surface scans of the foot under different loading conditions, and detailed gait analysis including kinematic, kinetic, muscle activity and plantar pressure measurements in both barefoot and shod conditions. Following this each participant will undergo computed tomography (CT imaging of their foot and ankle under a range of loads and positions while plantar pressures are recorded. A further subgroup of participants will undergo magnetic resonance imaging (MRI of the foot and ankle. Imaging data will be segmented to derive the geometry of the bones and the orientation of the joint axes. Insertion points of muscles and ligaments will be determined from the MRI and CT-scans and soft tissue material properties computed from the loaded CT data in combination with the plantar pressure measurements. Gait analysis data will be used to drive the models and in combination with the 3D surface scans for scaling purposes. Predicted plantar pressures and muscle activation patterns predicted from the models will be compared to determine the validity of the models. Discussion This protocol will lead to the generation of unique datasets which will be used

  15. Foot problems in a group of patients with rheumatoid arthritis: an unmet need for foot care.

    Science.gov (United States)

    Borman, Pinar; Ayhan, Figen; Tuncay, Figen; Sahin, Mehtap

    2012-01-01

    The aim of this study was to evaluate the foot involvement in a group of RA patients in regard to symptoms, type and frequency of deformities, location, radiological changes, and foot care. A randomized selected 100 rheumatoid arthritis (RA) patients were recruited to the study. Data about foot symptoms, duration and location of foot pain, pain intensity, access to services related to foot, treatment, orthoses and assistive devices, and usefulness of therapies were determined by the questionnaire. Radiological changes were assessed according to modified Larsen scoring system. The scores of disease activity scale of 28 joints and Health Assessment Questionnaire indicating the functional status of RA patients were collected from patient files. A total of 100 RA patients (90 female, 10 male) with a mean age of 52.5 ±10.9 years were enrolled to the study. Eighty-nine of the 100 patients had experienced foot complaints/symptoms in the past or currently. Foot pain and foot symptoms were reported as the first site of involvement in 14 patients. Thirty-six patients had ankle pain and the most common sites of the foot symptoms were ankle (36%) and forefoot (30%) followed by hindfoot (17%) and midfoot (7%) currently. Forty-nine of the patients described that they had difficulty in performing their foot care. Insoles and orthopedic shoes were prescribed in 39 patients, but only 14 of them continued to use them. The main reasons for not wearing them were; 17 not helpful (43%), 5 made foot pain worse (12.8%), and 3 did not fit (7.6%). Foot symptoms were reported to be decreased in 24 % of the subjects after the medical treatment and 6 patients indicated that they had underwent foot surgery. Current foot pain was significantly associated with higher body mass index and longer disease duration, and duration of morning stiffness. The radiological scores did not correlate with duration of foot symptoms and current foot pain (p>0.05) but the total number of foot deformities was

  16. The role of foot morphology on foot function in diabetic subjects with or without neuropathy.

    Science.gov (United States)

    Guiotto, Annamaria; Sawacha, Zimi; Guarneri, Gabriella; Cristoferi, Giuseppe; Avogaro, Angelo; Cobelli, Claudio

    2013-04-01

    The aim of this study was to investigate the role of foot morphology, related with respect to diabetes and peripheral neuropathy in altering foot kinematics and plantar pressure during gait. Healthy and diabetic subjects with or without neuropathy with different foot types were analyzed. Three dimensional multisegment foot kinematics and plantar pressures were assessed on 120 feet: 40 feet (24 cavus, 20 with valgus heel and 11 with hallux valgus) in the control group, 80 feet in the diabetic (25 cavus 13 with valgus heel and 13 with hallux valgus) and the neuropathic groups (28 cavus, 24 with valgus heel and 18 with hallux valgus). Subjects were classified according to their foot morphology allowing further comparisons among the subgroups with the same foot morphology. When comparing neuropathic subjects with cavus foot, valgus heel with controls with the same foot morphology, important differences were noticed: increased dorsiflexion and peak plantar pressure on the forefoot (Pfoot morphology in altering both kinematics and plantar pressure in diabetic subjects, diabetes appeared to further contribute in altering foot biomechanics. Surprisingly, all the diabetic subjects with normal foot arch or with valgus hallux were no more likely to display significant differences in biomechanics parameters than controls. This data could be considered a valuable support for future research on diabetic foot function, and in planning preventive interventions. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. The validity and accuracy in foot-to-foot bioelectrical impedance ...

    African Journals Online (AJOL)

    The validity and accuracy in foot-to-foot bioelectrical impedance analysis measuring models referenced by dual-energy X-ray absorptiometry in body composition in standing position. KC Hsieh, HK Lu, CH Chen, TR Jang, YY Chen, MF Kao ...

  18. Comparison of mechanical and biological properties of zirconia and titanium alloy orthodontic micro-implants.

    Science.gov (United States)

    Choi, Hae Won; Park, Young Seok; Chung, Shin Hye; Jung, Min Ho; Moon, Won; Rhee, Sang Hoon

    2017-07-01

    The aim of this study was to compare the initial stability as insertion and removal torque and the clinical applicability of novel orthodontic zirconia micro-implants made using a powder injection molding (PIM) technique with those parameters in conventional titanium micro-implants. Sixty zirconia and 60 titanium micro-implants of similar design (diameter, 1.6 mm; length, 8.0 mm) were inserted perpendicularly in solid polyurethane foam with varying densities of 20 pounds per cubic foot (pcf), 30 pcf, and 40 pcf. Primary stability was measured as maximum insertion torque (MIT) and maximum removal torque (MRT). To investigate clinical applicability, compressive and tensile forces were recorded at 0.01, 0.02, and 0.03 mm displacement of the implants at angles of 0°, 10°, 20°, 30°, and 40°. The biocompatibility of zirconia micro-implants was assessed via an experimental animal study. There were no statistically significant differences between zirconia micro-implants and titanium alloy implants with regard to MIT, MRT, or the amount of movement in the angulated lateral displacement test. As angulation increased, the mean compressive and tensile forces required to displace both types of micro-implants increased substantially at all distances. The average bone-to-implant contact ratio of prototype zirconia micro-implants was 56.88 ± 6.72%. Zirconia micro-implants showed initial stability and clinical applicability for diverse orthodontic treatments comparable to that of titanium micro-implants under compressive and tensile forces.

  19. Investigating Knee Alignment and Foot Structure in Futsal Players with and without Hamstring Shortness

    Directory of Open Access Journals (Sweden)

    Homan Minoonejad

    2016-09-01

    Methods: In this descriptive - comparative study, 30 men athlete (18- 25 years were recruited. They were assigned into two groups of 15 subjects with and without hamstring shortness. The hamstring shortness, knee and foot alignment were respectively measured by the goniometer, the ruler and caliper. After checking the normality of the data, (with Shapiro-Wilk test independent samples t-test, were used to analyze of data at a significance level of P 0.05. Conclusion: It seems that, navicular drop is not common among athletes with hamstring shortness.

  20. Mortality associated with acute Charcot foot and neuropathic foot ulceration

    NARCIS (Netherlands)

    van Baal, Juliette; Hubbard, Richard; Game, Fran; Jeffcoate, William

    2010-01-01

    To compare the mortality of patients with an acute Charcot foot with a matched population with uninfected neuropathic foot ulcers (NFUs). Data were extracted from a specialist departmental database, supplemented by hospital records. The findings were compared with the results of earlier populations

  1. Repeatability of the Oxford Foot Model in children with foot deformity.

    Science.gov (United States)

    McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim

    2018-03-01

    The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in pathological conditions. The aim of the study was to assess the repeatability of the OFM in children with foot deformity. Intra-tester repeatability was assessed for 45 children (15 typically developing, 15 hemiplegic, 15 clubfoot). Inter-tester repeatability was assessed in the clubfoot population. The mean absolute differences between testers (clubfoot) and sessions (clubfoot and hemiplegic) were calculated for each of 15 clinically relevant, kinematic variables and compared to typically developing children. Children with clubfoot showed a mean difference between visits of 2.9° and a mean difference between raters of 3.6° Mean absolute differences were within one degree for the intra and inter-rater reliability in 12/15 variables. Hindfoot rotation, forefoot/tibia abduction and forefoot supination were the most variable between testers. Overall the clubfoot data were less variable than the typically developing population. Children with hemiplegia demonstrated slightly higher differences between sessions (mean 4.1°), with the most reliable data in the sagittal plane, and largest differences in the transverse plane. The OFM was designed to measure different types of foot deformity. The results of this study show that it provides repeatable results in children with foot deformity. To be distinguished from measurement artifact, changes in foot kinematics as a result of intervention or natural progression over time must be greater than the repeatability reported here. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Gender differences of foot characteristics in older Japanese adults using a 3D foot scanner.

    Science.gov (United States)

    Saghazadeh, Mahshid; Kitano, Naruki; Okura, Tomohiro

    2015-01-01

    Knowledge of gender differences in foot shape assists shoe manufactures with designing appropriate shoes for men and women. Although gender differences in foot shapes are relatively known among young men and women, less is known about how the older men and women's feet differ in shape. A recent development in foot shape assessment is the use of 3D foot scanners. To our knowledge this technology has yet to be used to examine gender differences in foot shape of Japanese older adults. This cross-sectional study included 151 older men (74.5 ± 5.6 years) and 140 older women (73.9 ± 5.1 years) recruited in Kasama City, Japan. Foot variables were measured in sitting and standing positions using Dream GP Incorporated's 3D foot scanner, Footstep PRO (Osaka, Japan). Scores were analyzed as both raw and normalized to truncated foot length using independent samples t-test and analysis of covariance, respectively. In men, the measurement values for navicular height, first and fifth toe and instep heights, ball and heel width, ball girth, arch height index (just standing), arch rigidity index and instep girth were significantly greater than the women's, whereas the first toe angle, in both sitting and standing positions was significantly smaller. However, after normalizing, the differences in ball width, heel width, height of first and fifth toes in both sitting and standing and ball girth in sitting position were nonsignificant. According to Cohen's d, among all the foot variables, the following had large effect sizes in both sitting and standing positions: truncated foot length, instep, navicular height, foot length, ball girth, ball width, heel width and instep girth. This study provides evidence of anthropometric foot variations between older men and women. These differences need to be considered when manufacturing shoes for older adults.

  3. Inter-segment foot motion in girls using a three-dimensional multi-segment foot model.

    Science.gov (United States)

    Jang, Woo Young; Lee, Dong Yeon; Jung, Hae Woon; Lee, Doo Jae; Yoo, Won Joon; Choi, In Ho

    2018-05-06

    Several multi-segment foot models (MFMs) have been introduced for in vivo analyses of dynamic foot kinematics. However, the normal gait patterns of healthy children and adolescents remain uncharacterized. We sought to determine normal foot kinematics according to age in clinically normal female children and adolescents using a Foot 3D model. Fifty-eight girls (age 7-17 years) with normal function and without radiographic abnormalities were tested. Three representative strides from five separate trials were analyzed. Kinematic data of foot segment motion were tracked and evaluated using an MFM with a 15-marker set (Foot 3D model). As controls, 50 symptom-free female adults (20-35 years old) were analyzed. In the hindfoot kinematic analysis, plantar flexion motion in the pre-swing phase was significantly greater in girls aged 11 years or older than in girls aged foot progression angle showed mildly increased internal rotation in the loading response phase and the swing phase in girls aged foot motion in girls aged 11 years or older showed low-arch kinematic characteristics, whereas those in girls aged 11 years or older were more similar to the patterns in young adult women. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Foot anthropometry and morphology phenomena.

    Science.gov (United States)

    Agić, Ante; Nikolić, Vasilije; Mijović, Budimir

    2006-12-01

    Foot structure description is important for many reasons. The foot anthropometric morphology phenomena are analyzed together with hidden biomechanical functionality in order to fully characterize foot structure and function. For younger Croatian population the scatter data of the individual foot variables were interpolated by multivariate statistics. Foot structure descriptors are influenced by many factors, as a style of life, race, climate, and things of the great importance in human society. Dominant descriptors are determined by principal component analysis. Some practical recommendation and conclusion for medical, sportswear and footwear practice are highlighted.

  5. A methodological framework for detecting ulcers' risk in diabetic foot subjects by combining gait analysis, a new musculoskeletal foot model and a foot finite element model.

    Science.gov (United States)

    Scarton, Alessandra; Guiotto, Annamaria; Malaquias, Tiago; Spolaor, Fabiola; Sinigaglia, Giacomo; Cobelli, Claudio; Jonkers, Ilse; Sawacha, Zimi

    2018-02-01

    Diabetic foot is one of the most debilitating complications of diabetes and may lead to plantar ulcers. In the last decade, gait analysis, musculoskeletal modelling (MSM) and finite element modelling (FEM) have shown their ability to contribute to diabetic foot prevention and suggested that the origin of the plantar ulcers is in deeper tissue layers rather than on the plantar surface. Hence the aim of the current work is to develop a methodology that improves FEM-derived foot internal stresses prediction, for diabetic foot prevention applications. A 3D foot FEM was combined with MSM derived force to predict the sites of excessive internal stresses on the foot. In vivo gait analysis data, and an MRI scan of a foot from a healthy subject were acquired and used to develop a six degrees of freedom (6 DOF) foot MSM and a 3D subject-specific foot FEM. Ankle kinematics were applied as boundary conditions to the FEM together with: 1. only Ground Reaction Forces (GRFs); 2. OpenSim derived extrinsic muscles forces estimated with a standard OpenSim MSM; 3. extrinsic muscle forces derived through the (6 DOF) foot MSM; 4. intrinsic and extrinsic muscles forces derived through the 6 DOF foot MSM. For model validation purposes, simulated peak pressures were extracted and compared with those measured experimentally. The importance of foot muscles in controlling plantar pressure distribution and internal stresses is confirmed by the improved accuracy in the estimation of the peak pressures obtained with the inclusion of intrinsic and extrinsic muscle forces. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Analysis of foot kinematics wearing high heels using the Oxford foot model.

    Science.gov (United States)

    Wang, Meizi; Gu, Yaodong; Baker, Julien Steven

    2018-04-29

    Wearing high heels is thought to lead to various foot disorders and injuries such as metatarsal pain, Achilles tendon tension, plantar fasciitis and Haglund malformation. However, there is little available information explaining the specific mechanisms and reasons why wearing high heels causes foot deformity. Therefore, the purpose of this study was to investigate the foot kinematics of high heel wearers and compare any differences with barefoot individuals using the Oxford Foot Model (OFM). Fifteen healthy women aged 20-25 years were measured while walking barefoot and when wearing high heels. The peak value of angular motion for the hallux with respect to the forefoot, the forefoot with respect to the hind foot, and the hind foot with respect to the tibia were all analyzed. Compared to the barefoot, participants wearing high heels demonstrated larger hallux dorsiflexion (22.55∘± 1.62∘ VS 26.6∘± 2.33∘ for the barefoot; P= 0.001), and less hallux plantarflexion during the initial stance phase (-4.86∘± 2.32∘ VS -8.68∘± 1.13∘; Pfoot demonstrated a larger dorsiflexion in the horizontal plane (16.59∘± 1.69∘ VS 12.08∘± 0.9∘; Pfoot extension rotation (-5.49∘± 0.69∘ VS -10.73∘± 0.42∘; P= 0.001). These findings complement existing kinematic evidence that wearing high heels can lead to foot deformities and injuries.

  7. Reliability and normative values of the foot line test: a technique to assess foot posture

    DEFF Research Database (Denmark)

    Brushøj, C; Larsen, Klaus; Nielsen, MB

    2007-01-01

    STUDY DESIGN: Test-retest reliability. OBJECTIVE: To examine the reliability and report normative values of a novel test, the foot line test (FLT), to describe foot morphology. BACKGROUND: Numerous foot examinations are performed each day, but most existing examination techniques have considerable...... limitations regarding reliability and validity. METHODS: One hundred thirty subjects with mean foot size 44 (41-50 European size) participated. Two examiners, blinded to each other's measurements, measured the right foot of the subjects twice and the left foot once. The position of the most medial aspect...... of the navicular in the mediolateral direction was projected vertically onto a piece of paper placed under the subject's foot, and compared to the position of the forefoot and hindfoot to obtain the FLT value. RESULTS: FLT values ranged from -8 to 14 mm, with a mean (+/-SD) of 3.7 +/- 3.4 mm. The intratester...

  8. Relationship between sagittal plane kinematics, foot morphology and vertical forces applied to three regions of the foot

    OpenAIRE

    Hannah, I.; Sawacha, Z.; Guiotto, A.; Mazza, C.

    2016-01-01

    Kinetic analysis of human motion with a multi-segment musculoskeletal foot model requires the distribution of loading applied to the modeled foot segments to be determined. This work thus examines the existence of any correlation between intersegmental foot kinematics, foot morphology, and the distribution of vertical loading in a multi-segment foot model. Gait analysis trials were performed by 20 healthy subjects at a self-selected speed with intersegmental foot joint angles and the distribu...

  9. The effect of implant macro-thread design on implant stability in the early post-operative period: a randomized, controlled pilot study.

    Science.gov (United States)

    McCullough, Jeffrey J; Klokkevold, Perry R

    2017-10-01

    Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread design on this process is scant. The specific aim of this study was to evaluate the role of macro-thread design on implant stability in the early post-operative healing period using resonance frequency analysis (RFA). Seven patients, each missing at least two posterior teeth in the same arch, were included in the study. Three patients qualified for four implants resulting in a total of 10 matched pairs. All sites were healed (>6 months), non-grafted sites with sufficient bone to place implants. Each site in a matched pair was randomly assigned to receive either a control (Megagen EZ Plus Internal; EZ) or test (Megagen AnyRidge; AR) implant. The test implant incorporates a novel thread design with a wide thread depth and increased thread pitch. RFA was used to determine implant stability quotient (ISQ) values for each implant at the time of placement and weekly for the first 8 weeks. Implants consistently achieved a relatively high insertion torque (30-45 N/cm) and high initial ISQ value (79.8 ± 1.49). Baseline ISQ values for test (AR; 79.55 ± 1.61) and control (EZ; 80.05 ± 1.37) implants were similar. A general pattern of stability from baseline through all eight follow-up evaluations was observed for the test implants. A pattern of decreasing ISQ values was observed for the control implants across the early follow-up evaluations up to week four, where the value plateaued. There was a statistically significant main effect due to implant type (P implant type and time (P implants performed differently at certain time points. Within the limitations of this study, macro-thread design appears to play a role in implant stability in the early post

  10. Beyond the Bottom of the Foot: Topographic Organization of the Foot Dorsum in Walking.

    Science.gov (United States)

    Klarner, Taryn; Pearcey, Gregory E P; Sun, Yao; Barss, Trevor S; Kaupp, Chelsea; Munro, Bridget; Frank, Nick; Zehr, E Paul

    2017-12-01

    Sensory feedback from the foot dorsum during walking has only been studied globally by whole nerve stimulation. Stimulating the main nerve innervating the dorsal surface produces a functional stumble corrective response that is phase-dependently modulated. We speculated that effects evoked by activation of discrete skin regions on the foot dorsum would be topographically organized, as with the foot sole. Nonnoxious electrical stimulation was delivered to five discrete locations on the dorsal surface of the foot during treadmill walking. Muscle activity from muscles acting at the ankle, knee, hip, and shoulder were recorded along with ankle, knee, and hip kinematics and kinetic information from forces under the foot. All data were sorted on the basis of stimulus occurrence in 12 step cycle phases, before being averaged together within a phase for subsequent analysis. Results reveal dynamic changes in reflex amplitudes and kinematics that are site specific and phase dependent. Most responses from discrete sites on the foot dorsum were seen in the swing phase suggesting function to conform foot trajectory to maintain stability of the moving limb. In general, responses from lateral stimulation differed from medial stimulation, and effects were largest from stimulation at the distal end of the foot at the metatarsals; that is, in anatomical locations where actual impact with an object in the environment is most likely during swing. Responses to stimulation extend to include muscles at the hip and shoulder. We reveal that afferent feedback from specific cutaneous locations on the foot dorsum influences stance and swing phase corrective responses. This emphasizes the critical importance of feedback from the entire foot surface in locomotor control and has application for rehabilitation after neurological injury and in footwear development.

  11. Effects of seed migration on post-implant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Gao, M.; Wang, J. Z.; Nag, S.; Gupta, N.

    2007-01-01

    Brachytherapy using permanent seed implants has been an effective treatment for prostate cancer. However, seeds will migrate after implant, thus making the evaluation of post-implant dosimetry difficult. In this study, we developed a computer program to simulate seed migration and analyzed dosimetric changes due to seed migration at various migration amounts. The study was based on 14 patients treated with Pd-103 at the James Cancer Hospital. Modeling of seed migration, including direction, distance as well as day of migration, was based on clinical observations. Changes of commonly used dosimetric parameters as a function of migration amount (2, 4, 6 mm respectively), prostate size (from 20 to 90 cc), and prostate region (central vs peripheral) were studied. Change of biological outcome (tumor control probability) due to migration was also estimated. Migration reduced prostate D90 to 99±2% of original value in 2 mm migration, and the reduction increased to 94±6% in 6 mm migration. The reduction of prostate dose led to a 14% (40%) drop in the tumor control probability for 2 mm (6 mm) migration, assuming radiosensitive tumors. However, migration has less effect on a prostate implanted with a larger number of seeds. Prostate V100 was less sensitive to migration than D90 since its mean value was still 99% of original value even in 6 mm migration. Migration also showed a different effect in the peripheral region vs the central region of the prostate, where the peripheral mean dose tended to drop more significantly. Therefore, extra activity implanted in the peripheral region during pre-plan can be considered. The detrimental effects of migration were more severe in terms of increasing the dose to normal structures, as rectum V50 may be 70% higher and urethra V100 may be 50% higher in the case of 6 mm migration. Quantitative knowledge of these effects is helpful in treatment planning and post-implant evaluation

  12. Classification of the height and flexibility of the medial longitudinal arch of the foot.

    Science.gov (United States)

    Nilsson, Mette Kjærgaard; Friis, Rikke; Michaelsen, Maria Skjoldahl; Jakobsen, Patrick Abildgaard; Nielsen, Rasmus Oestergaard

    2012-02-17

    The risk of developing injuries during standing work may vary between persons with different foot types. High arched and low arched feet, as well as rigid and flexible feet, are considered to have different injury profiles, while those with normal arches may sustain fewer injuries. However, the cut-off values for maximum values (subtalar position during weight-bearing) and range of motion (ROM) values (difference between subtalar neutral and subtalar resting position in a weight-bearing condition) for the medial longitudinal arch (MLA) are largely unknown. The purpose of this study was to identify cut-off values for maximum values and ROM of the MLA of the foot during static tests and to identify factors influencing foot posture. The participants consisted of 254 volunteers from Central and Northern Denmark (198 m/56 f; age 39.0 ± 11.7 years; BMI 27.3 ± 4.7 kg/m2). Navicular height (NH), longitudinal arch angle (LAA) and Feiss line (FL) were measured for either the left or the right foot in a subtalar neutral position and subtalar resting position. Maximum values and ROM were calculated for each test. The 95% and 68% prediction intervals were used as cut-off limits. Multiple regression analysis was used to detect influencing factors on foot posture. The 68% cut-off values for maximum MLA values and MLA ROM for NH were 3.6 to 5.5 cm and 0.6 to 1.8 cm, respectively, without taking into account the influence of other variables. Normal maximum LAA values were between 131 and 152° and normal LAA ROM was between -1 and 13°. Normal maximum FL values were between -2.6 and -1.2 cm and normal FL ROM was between -0.1 and 0.9 cm. Results from the multivariate linear regression revealed an association between foot size with FL, LAA, and navicular drop. The cut-off values presented in this study can be used to categorize people performing standing work into groups of different foot arch types. The results of this study are important for investigating a possible link between

  13. Classification of the height and flexibility of the medial longitudinal arch of the foot

    Directory of Open Access Journals (Sweden)

    Nilsson Mette

    2012-02-01

    Full Text Available Abstract Background The risk of developing injuries during standing work may vary between persons with different foot types. High arched and low arched feet, as well as rigid and flexible feet, are considered to have different injury profiles, while those with normal arches may sustain fewer injuries. However, the cut-off values for maximum values (subtalar position during weight-bearing and range of motion (ROM values (difference between subtalar neutral and subtalar resting position in a weight-bearing condition for the medial longitudinal arch (MLA are largely unknown. The purpose of this study was to identify cut-off values for maximum values and ROM of the MLA of the foot during static tests and to identify factors influencing foot posture. Methods The participants consisted of 254 volunteers from Central and Northern Denmark (198 m/56 f; age 39.0 ± 11.7 years; BMI 27.3 ± 4.7 kg/m2. Navicular height (NH, longitudinal arch angle (LAA and Feiss line (FL were measured for either the left or the right foot in a subtalar neutral position and subtalar resting position. Maximum values and ROM were calculated for each test. The 95% and 68% prediction intervals were used as cut-off limits. Multiple regression analysis was used to detect influencing factors on foot posture. Results The 68% cut-off values for maximum MLA values and MLA ROM for NH were 3.6 to 5.5 cm and 0.6 to 1.8 cm, respectively, without taking into account the influence of other variables. Normal maximum LAA values were between 131 and 152° and normal LAA ROM was between -1 and 13°. Normal maximum FL values were between -2.6 and -1.2 cm and normal FL ROM was between -0.1 and 0.9 cm. Results from the multivariate linear regression revealed an association between foot size with FL, LAA, and navicular drop. Conclusions The cut-off values presented in this study can be used to categorize people performing standing work into groups of different foot arch types. The results of this

  14. Effects of sodium hyaluronate on ocular inflammatory response and dry eye after phacoemulsification combined with IOL implantation for cataract

    Directory of Open Access Journals (Sweden)

    Xing-Guang He

    2018-04-01

    Full Text Available AIM: To investigate the effect of sodium hyaluronate eye drops on ocular inflammatory response and dry eye after phacoemulsification combined with intraocular lenses(IOLimplantation for age-related cataract. METHODS: The clinical data of age-related cataract patients treated with phacoemulsification combined with IOL implantation in 200 cases(200 eyesof our hospital from June 2016 to July 2017 were retrospectively analyzed. According to the different postoperative application of eye drops they were divided into observation group and control group(100 cases each. The observation group was given sodium hyaluronate eye drops and the control group was given tobramycin dexamethasone eye drops. The results of BUT, FL, proteins concentration in aqueous and ocular surface disease index(OSDIscore were compared before and at the first day, the seventh day and the fourteenth day after the operation. And the incidence of conjunctival hyperemia and ciliary hyperemia was compared between 1d after surgery and 14d after surgery. RESULTS: There was no significant difference in OSDI scores between the two groups before and at 1d after surgery(P>0.05. The OSDI score of the two groups was higher than that before the operation on the first, the seventh and the fourteenth day after surgery(PPPP>0.05. The levels of BUT in the two groups were lower than those before operation on the first, the seventh and the fourteenth day after surgery(PPPP>0.05. The levels of FL in the two groups were different from those before operation(PPPPP>0.05; the incidence of conjunctival hyperemia and ciliary hyperemia in the two groups on the fourteenth day after surgery was lower than that on the first day after surgery(PPPPPCONCLUSION: The effect of sodium hyaluronate eye drops on improving dry eye after age-related cataract phacoemulsification combined with IOL implantation is greater than that of tobramycin dexamethasone eye drops, but it is less effective for eye inflammation than

  15. Foot Problems in a Group of Patients with Rheumatoid Arthritis: An Unmet Need for Foot Care

    OpenAIRE

    Borman, Pinar; Ayhan, Figen; Tuncay, Figen; Sahin, Mehtap

    2012-01-01

    Objectives: The aim of this study was to evaluate the foot involvement in a group of RA patients in regard to symptoms, type and frequency of deformities, location, radiological changes, and foot care. Patients and Methods: A randomized selected 100 rheumatoid arthritis (RA) patients were recruited to the study. Data about foot symptoms, duration and location of foot pain, pain intensity, access to services related to foot, treatment, orthoses and assistive devices, and usefulness of therapie...

  16. Relationship between Leg Mass, Leg Composition and Foot Velocity on Kicking Accuracy in Australian Football.

    Science.gov (United States)

    Hart, Nicolas H; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L; Newton, Robert U

    2016-06-01

    Kicking a ball accurately over a desired distance to an intended target is arguably the most important skill to acquire in Australian Football. Therefore, understanding the potential mechanisms which underpin kicking accuracy is warranted. The aim of this study was to examine the relationship between leg mass, leg composition and foot velocity on kicking accuracy in Australian Football. Thirty-one Australian Footballers (n = 31; age: 22.1 ± 2.8 years; height: 1.81 ± 0.07 m; weight: 85.1 ± 13.0 kg; BMI: 25.9 ± 3.2) each performed ten drop punt kicks over twenty metres to a player target. Athletes were separated into accurate (n = 15) and inaccurate (n = 16) kicking groups. Leg mass characteristics were assessed using whole body DXA scans. Foot velocity was determined using a ten-camera optoelectronic, three-dimensional motion capture system. Interactions between leg mass and foot velocity evident within accurate kickers only (r = -0.670 to -0.701). Relative lean mass was positively correlated with kicking accuracy (r = 0.631), while no relationship between foot velocity and kicking accuracy was evident in isolation (r = -0.047 to -0.083). Given the evident importance of lean mass, and its interaction with foot velocity for accurate kickers; future research should explore speed-accuracy, impulse-variability, limb co-ordination and foot-ball interaction constructs in kicking using controlled with-in subject studies to examine the effects of resistance training and skill acquisition programs on the development of kicking accuracy. Key pointsAccurate kickers expressed a very strong inverse relationship between leg mass and foot velocity. Inaccurate kickers were unable to replicate this, with greater volatility in their performance, indicating an ability of accurate kickers to mediate foot velocity to compensate for leg mass in order to deliver the ball over the required distance.Accurate kickers exhibited larger quantities of relative lean mass and lower quantities

  17. Natural gaits of the non-pathological flat foot and high-arched foot.

    Science.gov (United States)

    Fan, Yifang; Fan, Yubo; Li, Zhiyu; Lv, Changsheng; Luo, Donglin

    2011-03-18

    There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static footprints from subjects adopting a half-weight-bearing stance. Based upon their footprints, the subjects were divided into two groups: the flat-footed and the high-arched. The plantar pressure measurement system was used to measure and record the subjects' successive natural gaits. Two indices were proposed: distribution of vertical ground reaction force (VGRF) of plantar and the rate of change of footprint areas. Using these two indices to compare the natural gaits of the two subject groups, we found that (1) in stance phase, there is a significant difference (pplantar; (2) in a stride cycle, there is also a significant difference (pfootprint area. Our analysis suggests that when walking, the VGRF of the plantar brings greater muscle tension to the flat-footed while a smaller rate of change of footprint area brings greater stability to the high-arched.

  18. From the diabetic foot ulcer and beyond: how do foot infections spread in patients with diabetes?

    Science.gov (United States)

    Aragón-Sánchez, Javier; Lázaro-Martínez, Jose Luis; Pulido-Duque, Juan; Maynar, Manuel

    2012-01-01

    A diabetic foot infection is usually the result of a pre-existing foot ulceration and is the leading cause of lower extremity amputation in patients with diabetes. It is widely accepted that diabetic foot infections may be challenging to treat for several reasons. The devastating effects of hyperglycemia on host defense, ischemia, multi-drug resistant bacteria and spreading of infection through the foot may complicate the course of diabetic foot infections. Understanding the ways in which infections spread through the diabetic foot is a pivotal factor in order to decide the best approach for the patient's treatment. The ways in which infections spread can be explained by the anatomical division of the foot into compartments, the tendons included in the compartments, the initial location of the point of entry of the infection and the type of infection that the patient has. The aim of this paper is to further comment on the existed and proposed anatomical principles of the spread of infection through the foot in patients with diabetes. PMID:23050067

  19. The Glasgow-Maastricht foot model, evaluation of a 26 segment kinematic model of the foot.

    Science.gov (United States)

    Oosterwaal, Michiel; Carbes, Sylvain; Telfer, Scott; Woodburn, James; Tørholm, Søren; Al-Munajjed, Amir A; van Rhijn, Lodewijk; Meijer, Kenneth

    2016-01-01

    Accurately measuring of intrinsic foot kinematics using skin mounted markers is difficult, limited in part by the physical dimensions of the foot. Existing kinematic foot models solve this problem by combining multiple bones into idealized rigid segments. This study presents a novel foot model that allows the motion of the 26 bones to be individually estimated via a combination of partial joint constraints and coupling the motion of separate joints using kinematic rhythms. Segmented CT data from one healthy subject was used to create a template Glasgow-Maastricht foot model (GM-model). Following this, the template was scaled to produce subject-specific models for five additional healthy participants using a surface scan of the foot and ankle. Forty-three skin mounted markers, mainly positioned around the foot and ankle, were used to capture the stance phase of the right foot of the six healthy participants during walking. The GM-model was then applied to calculate the intrinsic foot kinematics. Distinct motion patterns where found for all joints. The variability in outcome depended on the location of the joint, with reasonable results for sagittal plane motions and poor results for transverse plane motions. The results of the GM-model were comparable with existing literature, including bone pin studies, with respect to the range of motion, motion pattern and timing of the motion in the studied joints. This novel model is the most complete kinematic model to date. Further evaluation of the model is warranted.

  20. Priorities in offloading the diabetic foot

    NARCIS (Netherlands)

    Bus, Sicco A.

    2012-01-01

    Biomechanical factors play an important role in diabetic foot disease. Reducing high foot pressures (i.e. offloading) is one of the main goals in healing and preventing foot ulceration. Evidence-based guidelines show the strong association between the efficacy to offload the foot and clinical

  1. Reliable experimental setup to test the pressure modulation of Baerveldt Implant tubes for reducing post-operative hypotony

    Science.gov (United States)

    Ramani, Ajay

    Glaucoma encompasses a group of conditions that result in damage to the optic nerve and can cause loss of vision and blindness. The nerve is damaged due to an increase in the eye's internal (intraocular) pressure (IOP) above the nominal range of 15 -- 20 mm Hg. There are many treatments available for this group of diseases depending on the complexity and stage of nerve degradation. In extreme cases where drugs or laser surgery do not create better conditions for the patient, ophthalmologists use glaucoma drainage devices to help alleviate the IOP. Many drainage implants have been developed over the years and are in use; but two popular implants are the Baerveldt Glaucoma Implant and the Ahmed Glaucoma Valve Implant. Baerveldt Implants are non-valved and provide low initial resistance to outflow of fluid, resulting in post-operative complications such as hypotony, where the IOP drops below 5 mm of Hg. Ahmed Glaucoma Valve Implants are valved implants which initially restrict the amount of fluid flowing out of the eye. The long term success rates of Baerveldt Implants surpass those of Ahmed Valve Implants because of post-surgical issues; but Baerveldt Implants' initial effectiveness is poor without proper flow restriction. This drives the need to develop new ways to improve the initial effectiveness of Baerveldt Implants. A possible solution proposed by our research team is to place an insert in the Baerveldt Implant tube of inner diameter 305 microns. The insert must be designed to provide flow resistance for the early time frame [e.g., first 30 -- 60 post-operative days] until sufficient scar tissue has formed on the implant. After that initial stage with the insert, the scar tissue will provide the necessary flow resistance to maintain the IOP above 5 mm Hg. The main objective of this project was to develop and validate an experimental apparatus to measure pressure drop across a Baerveldt Implant tube, with and without inserts. This setup will be used in the

  2. The Glasgow-Maastricht foot model, evaluation of a 26 segment kinematic model of the foot

    OpenAIRE

    Oosterwaal, Michiel; Carbes, Sylvain; Telfer, Scott; Woodburn, James; T?rholm, S?ren; Al-Munajjed, Amir A.; van Rhijn, Lodewijk; Meijer, Kenneth

    2016-01-01

    Background Accurately measuring of intrinsic foot kinematics using skin mounted markers is difficult, limited in part by the physical dimensions of the foot. Existing kinematic foot models solve this problem by combining multiple bones into idealized rigid segments. This study presents a novel foot model that allows the motion of the 26 bones to be individually estimated via a combination of partial joint constraints and coupling the motion of separate joints using kinematic rhythms. Methods ...

  3. Education for diabetic foot

    Directory of Open Access Journals (Sweden)

    Fabio Batista

    2009-03-01

    Full Text Available Objective: The purpose of this investigation was to stratify the risk in a consecutive group of diabetic patients presenting, for the first time, in a diabetic foot clinic. Additional aims were to investigate the preventive measures in the local health system and to evaluate the level of patient’s awareness about diabetic foot-associated morbidity. Methods: Fifty consecutive adult diabetic patients referred to a Diabetic Foot Clinic of a Municipal Public Hospital comprised the sample for this observational study. The enrollment visit was considered as the first health-system intervention for potential foot morbidity. The average time elapsed since a diagnosis of diabetes among patients was five years. Rresults: At the time of presentation, 94% of sample was not using appropriate footwear. Pedal pulses (dorsalis pedis and/or posterior tibial arteries were palpable in 76% of patients. Thirty subjects (60% had signs of peripheral neuropathy. Twenty-one subjects (42% had clinical deformity. There was a positive correlation between a history of foot ulcer, the presence of peripheral neuropathy, and the presence of foot deformity (p < 0.004 in each correlation. Cconclusions: Informing and educating the patients and those interested in this subject and these problems is essential for favorable outcomes in this scenario.

  4. Foot Health Facts for Athletes

    Science.gov (United States)

    ... common foot problems affecting athletes: Prevent Foot & Ankle Running Injuries (downloadable PDF) Back-to-School Soccer Season Surgeons ... and Ankle Soccer is hard on the feet! Injuries to the foot and ankle can occur from running and side-to-side cutting, sliding or tackling ...

  5. Assessment of morphological-functional state of children with cochlear implants

    Directory of Open Access Journals (Sweden)

    V.M. Pysanko

    2016-10-01

    Full Text Available Purpose: assessment of morphological-functional state of pre-school age children with cochlear implants and substantiation of need in post-operative rehabilitation in period of preparation for comprehensive school. Material: we tested weakly hearing children with cochlear implants (n=127, age - 5.6±0.6 years. They were the main group. Control group consisted of children with normal hearing (n=70, age - 5.7±0.4 years. Morphological-functional state was assessed by indicators of physical and biological condition, visual analyzer, posture parameters and foot arch, muscular system and level of coordination. We calculated index of integral morphological-functional state assessment. Results: Morphological functional state of most of children (with cochlear implants was characterized by low physical condition indicators and disharmony. We observed delay in biological development. Index of morphological-functional state integral assessment witnesses, that such child can not study in comprehensive school. Rehabilitation program can reduce the gap between children with normal hearing and those with cochlear implants. Conclusions: Rehabilitation program facilitates quicker domestic and social rehabilitation of children at the account of widening the circle of communication, learning new actions and conceptions. It can permit for such children to study at school together with their healthy peers.

  6. [Optimize dropping process of Ginkgo biloba dropping pills by using design space approach].

    Science.gov (United States)

    Shen, Ji-Chen; Wang, Qing-Qing; Chen, An; Pan, Fang-Lai; Gong, Xing-Chu; Qu, Hai-Bin

    2017-07-01

    In this paper, a design space approach was applied to optimize the dropping process of Ginkgo biloba dropping pills. Firstly, potential critical process parameters and potential process critical quality attributes were determined through literature research and pre-experiments. Secondly, experiments were carried out according to Box-Behnken design. Then the critical process parameters and critical quality attributes were determined based on the experimental results. Thirdly, second-order polynomial models were used to describe the quantitative relationships between critical process parameters and critical quality attributes. Finally, a probability-based design space was calculated and verified. The verification results showed that efficient production of Ginkgo biloba dropping pills can be guaranteed by operating within the design space parameters. The recommended operation ranges for the critical dropping process parameters of Ginkgo biloba dropping pills were as follows: dropping distance of 5.5-6.7 cm, and dropping speed of 59-60 drops per minute, providing a reference for industrial production of Ginkgo biloba dropping pills. Copyright© by the Chinese Pharmaceutical Association.

  7. Lambda-dropping

    DEFF Research Database (Denmark)

    Danvy, Olivier; Schultz, Ulrik Pagh

    1997-01-01

    Lambda-lifting a functional program transforms it into a set of recursive equations. We present the symmetric transformation: lambda-dropping. Lambda-dropping a set of recursive equations restores block structure and lexical scope.For lack of scope, recursive equations must carry around all...... the parameters that any of their callees might possibly need. Both lambda-lifting and lambda-dropping thus require one to compute a transitive closure over the call graph:• for lambda-lifting: to establish the Def/Use path of each free variable (these free variables are then added as parameters to each...... of the functions in the call path);• for lambda-dropping: to establish the Def/Use path of each parameter (parameters whose use occurs in the same scope as their definition do not need to be passed along in the call path).Without free variables, a program is scope-insensitive. Its blocks are then free...

  8. Sesamoid Injuries in the Foot

    Science.gov (United States)

    ... on the ball of the foot when walking, running and jumping. Sesamoid injuries can involve the bones, tendons and/or surrounding ... on the ball of the foot, such as running, basketball, football, golf, tennis and ballet. ... of Sesamoid Injuries in the Foot There are three types of ...

  9. Combined diabetic foot infections treatment, complicated by foot phlegmon

    Directory of Open Access Journals (Sweden)

    Yavruyan O.A.

    2017-01-01

    Full Text Available the article shows the analysis of treatment results of 163 patients with diabetic foot infections, complicated by foot phlegmon. Patients were divided into 2 groups. The control group received traditional treatment and had an autopsy deep plantar space done and then, during the second phase, cytokine-rich autoplatelet concentrate had been applied. The research results confirmed a significant decrease in the duration of treatment and hospitalization of patients in the hospital.

  10. PMMA embolization to the left dorsal foot artery during percutaneous vertebroplasty for spinal metastases.

    Science.gov (United States)

    Iliopoulos, Panagiotis; Panagiotis, Iliopoulos; Korovessis, Panagiotis; Panagiotis, Korovessis; Vitsas, Vasilios; Vasilios, Vitsas

    2014-05-01

    Distal arterial embolization to the foot with PMMA during vertebral augmentation has not been previously reported. We report a rare case of distal PMMA embolization to the dorsal foot artery during ipsilateral percutaneous lumbar vertebral augmentation in a patient with spinal osteolytic metastases. A 68-year-old woman was admitted because of severe disabling low back pain. Plain roentgenograms, MRI and CT-scan revealed osteolysis in the L4 and L5 vertebral bodies with prevertebral soft tissue involvement. Percutaneous vertebroplasty with PMMA was performed in L2 to L5 vertebrae under general anesthesia. Intraoperatively, leakage into the segmental vessels L3 and L5 was observed. Four hours after the procedure the clinical diagnosis of acute ischemia and drop foot on the left was made. CT-angiography justified linear cement leakage in the course of the left third lumbar vein and fifth lumbar artery, and to the ipsilateral common iliac artery. The patient was treated with low molecular heparin and the ischemia resolved without further sequelae 1 week postoperatively. PMMA leakage is a complication associated with vertebroplasty and kyphoplasty. Although the outcome of the PMMA embolization to the vessels resolved without sequelae, in our case spine surgeons and interventional radiologists should be aware on this rare complication in patients with osteolytic vertebral metastases even when contemporary cement containment techniques are used.

  11. Analytical Evaluation of Preliminary Drop Tests Performed to Develop a Robust Design for the Standardized DOE Spent Nuclear Fuel Canister

    International Nuclear Information System (INIS)

    Ware, A.G.; Morton, D.K.; Smith, N.L.; Snow, S.D.; Rahl, T.E.

    1999-01-01

    The Department of Energy (DOE) has developed a design concept for a set of standard canisters for the handling, interim storage, transportation, and disposal in the national repository, of DOE spent nuclear fuel (SNF). The standardized DOE SNF canister has to be capable of handling virtually all of the DOE SNF in a variety of potential storage and transportation systems. It must also be acceptable to the repository, based on current and anticipated future requirements. This expected usage mandates a robust design. The canister design has four unique geometries, with lengths of approximately 10 feet or 15 feet, and an outside nominal diameter of 18 inches or 24 inches. The canister has been developed to withstand a drop from 30 feet onto a rigid (flat) surface, sustaining only minor damage - but no rupture - to the pressure (containment) boundary. The majority of the end drop-induced damage is confined to the skirt and lifting/stiffening ring components, which can be removed if de sired after an accidental drop. A canister, with its skirt and stiffening ring removed after an accidental drop, can continue to be used in service with appropriate operational steps being taken. Features of the design concept have been proven through drop testing and finite element analyses of smaller test specimens. Finite element analyses also validated the canister design for drops onto a rigid (flat) surface for a variety of canister orientations at impact, from vertical to 45 degrees off vertical. Actual 30-foot drop testing has also been performed to verify the final design, though limited to just two full-scale test canister drops. In each case, the analytical models accurately predicted the canister response

  12. Outcomes of operative treatment of unstable ankle fractures: a comparison of metallic and biodegradable implants.

    Science.gov (United States)

    Noh, Jung Ho; Roh, Young Hak; Yang, Bo Gyu; Kim, Seong Wan; Lee, Jun Suk; Oh, Moo Kyung

    2012-11-21

    Biodegradable implants for internal fixation of ankle fractures may overcome some disadvantages of metallic implants, such as imaging interference and the potential need for additional surgery to remove the implants. The purpose of this study was to evaluate the outcomes after fixation of ankle fractures with biodegradable implants compared with metallic implants. In this prospectively randomized study, 109 subjects with an ankle fracture underwent surgery with metallic (Group I) or biodegradable implants (Group II). Radiographic results were assessed by the criteria of the Klossner classification system and time to bone union. Clinical results were assessed with use of the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale, Short Musculoskeletal Function Assessment (SMFA) dysfunction index, and the SMFA bother index at three, six, and twelve months after surgery. One hundred and two subjects completed the study. At a mean of 19.7 months, there were no differences in reduction quality between the groups. The mean operative time was 30.2 minutes in Group I and 56.4 minutes in Group II (p implants were inferior to those after fixation with metallic implants in terms of the score on the AOFAS scale and time to bone union. However, the difference in the final AOFAS score between the groups may not be clinically important. The outcomes associated with the use of biodegradable implants for the fixation of isolated lateral malleolar fractures were comparable with those for metallic implants.

  13. Magnitude and Spatial Distribution of Impact Intensity Under the Foot Relates to Initial Foot Contact Pattern.

    Science.gov (United States)

    Breine, Bastiaan; Malcolm, Philippe; Segers, Veerle; Gerlo, Joeri; Derie, Rud; Pataky, Todd; Frederick, Edward C; De Clercq, Dirk

    2017-12-01

    In running, foot contact patterns (rear-, mid-, or forefoot contact) influence impact intensity and initial ankle and foot kinematics. The aim of the study was to compare impact intensity and its spatial distribution under the foot between different foot contact patterns. Forty-nine subjects ran at 3.2 m·s -1 over a level runway while ground reaction forces (GRF) and shoe-surface pressures were recorded and foot contact pattern was determined. A 4-zone footmask (forefoot, midfoot, medial and lateral rearfoot) assessed the spatial distribution of the vertical GRF under the foot. We calculated peak vertical instantaneous loading rate of the GRF (VILR) per foot zone as the impact intensity measure. Midfoot contact patterns were shown to have the lowest, and atypical rearfoot contact patterns the highest impact intensities, respectively. The greatest local impact intensity was mainly situated under the rear- and midfoot for the typical rearfoot contact patterns, under the midfoot for the atypical rearfoot contact patterns, and under the mid- and forefoot for the midfoot contact patterns. These findings indicate that different foot contact patterns could benefit from cushioning in different shoe zones.

  14. Natural gaits of the non-pathological flat foot and high-arched foot.

    Directory of Open Access Journals (Sweden)

    Yifang Fan

    Full Text Available There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static footprints from subjects adopting a half-weight-bearing stance. Based upon their footprints, the subjects were divided into two groups: the flat-footed and the high-arched. The plantar pressure measurement system was used to measure and record the subjects' successive natural gaits. Two indices were proposed: distribution of vertical ground reaction force (VGRF of plantar and the rate of change of footprint areas. Using these two indices to compare the natural gaits of the two subject groups, we found that (1 in stance phase, there is a significant difference (p<0.01 in the distributions of VGRF of plantar; (2 in a stride cycle, there is also a significant difference (p<0.01 in the rate of change of footprint area. Our analysis suggests that when walking, the VGRF of the plantar brings greater muscle tension to the flat-footed while a smaller rate of change of footprint area brings greater stability to the high-arched.

  15. A new method to normalize plantar pressure measurements for foot size and foot progression angle.

    NARCIS (Netherlands)

    Keijsers, N.L.; Stolwijk, N.M.; Nienhuis, B.; Duysens, J.E.J.

    2009-01-01

    Plantar pressure measurement provides important information about the structure and function of the foot and is a helpful tool to evaluate patients with foot complaints. In general, average and maximum plantar pressure of 6-11 areas under the foot are used to compare groups of subjects. However,

  16. Diabetic foot disease: From the evaluation of the “foot at risk” to the novel diabetic ulcer treatment modalities

    Science.gov (United States)

    Amin, Noha; Doupis, John

    2016-01-01

    The burden of diabetic foot disease (DFD) is expected to increase in the future. The incidence of DFD is still rising due to the high prevalence of DFD predisposing factors. DFD is multifactorial in nature; however most of the diabetic foot amputations are preceded by foot ulceration. Diabetic peripheral neuropathy (DPN) is a major risk factor for foot ulceration. DPN leads to loss of protective sensation resulting in continuous unconscious traumas. Patient education and detection of high risk foot are essential for the prevention of foot ulceration and amputation. Proper assessment of the diabetic foot ulceration and appropriate management ensure better prognosis. Management is based on revascularization procedures, wound debridement, treatment of infection and ulcer offloading. Management and type of dressing applied are tailored according to the type of wound and the foot condition. The scope of this review paper is to describe the diabetic foot syndrome starting from the evaluation of the foot at risk for ulceration, up to the new treatment modalities. PMID:27076876

  17. 24 CFR 3285.312 - Footings.

    Science.gov (United States)

    2010-04-01

    ... reinforcing steel in cast-in-place concrete footings. (2) Pressure-treated wood. (i) Pressure-treated wood footings must consist of a minimum of two layers of nominal 2-inch thick pressure-treated wood, a single... values listed have been reduced by the dead load of the concrete footing. 4. Concrete block piers must...

  18. Foot muscles strengthener

    Directory of Open Access Journals (Sweden)

    Boris T. Glavač

    2012-04-01

    Full Text Available Previous experience in the correction of flat feet consisted of the use of insoles for shoes and exercises with toys, balls, rollers, inclined planes, etc. A device for strengthening foot muscles is designed for the correction of flat feet in children and, as its name suggests, for strengthening foot muscles in adults. The device is made of wood and metal, with a mechanism and technical solutions, enabling the implementation of specific exercises to activate muscles responsible for the formation of the foot arch. It is suitable for home use with controlled load quantities since it has calibrated springs. The device is patented with the Intellectual Property Office, Republic of Serbia, as a petty patent.

  19. Foot Complications in a Representative Australian Inpatient Population

    Directory of Open Access Journals (Sweden)

    Peter A. Lazzarini

    2017-01-01

    Full Text Available We investigated the prevalence and factors independently associated with foot complications in a representative inpatient population (adults admitted for any reason with and without diabetes. We analysed data from the Foot disease in inpatients study, a sample of 733 representative inpatients. Previous amputation, previous foot ulceration, peripheral arterial disease (PAD, peripheral neuropathy (PN, and foot deformity were the foot complications assessed. Sociodemographic, medical, and foot treatment history were collected. Overall, 46.0% had a foot complication with 23.9% having multiple; those with diabetes had higher prevalence of foot complications than those without diabetes (p<0.01. Previous amputation (4.1% was independently associated with previous foot ulceration, foot deformity, cerebrovascular accident, and past surgeon treatment (p<0.01. Previous foot ulceration (9.8% was associated with PN, PAD, past podiatry, and past nurse treatment (p<0.02. PAD (21.0% was associated with older age, males, indigenous people, cancer, PN, and past surgeon treatment (p<0.02. PN (22.0% was associated with older age, diabetes, mobility impairment, and PAD (p<0.05. Foot deformity (22.4% was associated with older age, mobility impairment, past podiatry treatment, and PN (p<0.01. Nearly half of all inpatients had a foot complication. Those with foot complications were older, male, indigenous, had diabetes, cerebrovascular accident, mobility impairment, and other foot complications or past foot treatment.

  20. What Is a Foot and Ankle Surgeon?

    Science.gov (United States)

    ... A A | Print | Share What is a Foot & Ankle Surgeon? Foot and ankle surgeons are the surgical ... every age. What education has a foot and ankle surgeon received? After completing undergraduate education, the foot ...

  1. Controlling charge on levitating drops.

    Science.gov (United States)

    Hilger, Ryan T; Westphall, Michael S; Smith, Lloyd M

    2007-08-01

    Levitation technologies are used in containerless processing of materials, as microscale manipulators and reactors, and in the study of single drops and particles. Presented here is a method for controlling the amount and polarity of charge on a levitating drop. The method uses single-axis acoustic levitation to trap and levitate a single, initially neutral drop with a diameter between 400 microm and 2 mm. This drop is then charged in a controllable manner using discrete packets of charge in the form of charged drops produced by a piezoelectric drop-on-demand dispenser equipped with a charging electrode. The magnitude of the charge on the dispensed drops can be adjusted by varying the voltage applied to the charging electrode. The polarity of the charge on the added drops can be changed allowing removal of charge from the trapped drop (by neutralization) and polarity reversal. The maximum amount of added charge is limited by repulsion of like charges between the drops in the trap. This charging scheme can aid in micromanipulation and the study of charged drops and particles using levitation.

  2. Sex-related differences in foot shape.

    Science.gov (United States)

    Krauss, I; Grau, S; Mauch, M; Maiwald, C; Horstmann, T

    2008-11-01

    The purpose of the study was to investigate sex-related differences in foot morphology. In total, 847 subjects were scanned using a 3-D-footscanner. Three different analysis methods were used: (1) comparisons were made for absolute foot measures within 250-270 mm foot length (FL); (2) and for averaged measures (% FL) across all sizes; (3) the feet were then classified using a cluster analysis. Within 250-270 mm FL, male feet were wider and higher (mean differences (MD) 1.3-5.9 mm). No relevant sex-related differences could be found in the comparison of averaged measures (MD 0.3-0.6% FL). Foot types were categorised into voluminous, flat-pointed and slender. Shorter feet were more often voluminous, longer feet were more likely to be narrow and flat. However, the definition of 'short' and 'long' was sex-related; thus, allometry of foot measures was different. For shoe design, measures should be derived for each size and sex separately. Different foot types should be considered to account for the variety in foot shape. Improper footwear can cause foot pain and deformity. Therefore, knowledge of sex-related differences in foot measures is important to assist proper shoe fit in both men and women. The present study supplements the field of knowledge within this context with recommendations for the manufacturing of shoes.

  3. Assessment of signs of foot infection in diabetes patients using photographic foot imaging and infrared thermography

    NARCIS (Netherlands)

    Hazenberg, Constantijn E. V. B.; van Netten, Jaap J.; van Baal, Sjef G.; Bus, Sicco A.

    2014-01-01

    Patients with diabetic foot disease require frequent screening to prevent complications and may be helped through telemedical home monitoring. Within this context, the goal was to determine the validity and reliability of assessing diabetic foot infection using photographic foot imaging and infrared

  4. Flip-flop footwear with a moulded foot-bed for the treatment of foot pain: a randomised controlled trial.

    Science.gov (United States)

    Chuter, Vivienne Helaine; Searle, Angela; Spink, Martin J

    2016-11-11

    Foot pain is a common problem affecting up to 1 in 5 adults and is known to adversely affect activities of daily living and health related quality of life. Orthopaedic footwear interventions are used as a conservative treatment for foot pain, although adherence is known to be low, in part due to the perception of poor comfort and unattractiveness of the footwear. The objective of this trial was to assess the efficacy of flip-flop style footwear (Foot Bio-Tec©) with a moulded foot-bed in reducing foot pain compared to participant's usual footwear. Two-arm parallel randomised controlled trial using computer generated random allocation schedule at an Australian university podiatry clinic. 108 volunteers with disabling foot pain were enrolled after responding to an advertisement and eligibility screening. Participants were randomly allocated to receive footwear education and moulded flip-flop footwear to wear as much as they were comfortable with for the next 12 weeks (n = 54) or footwear education and instructions to wear their normal footwear for the next 12 weeks (n = 54). Primary outcome was the pain domain of the Foot Health Status Questionnaire (FHSQ). Secondary outcomes were the foot function and general foot health domains of the FHSQ, a visual analogue scale (VAS) for foot pain and perceived comfort of the intervention footwear. Compared to the control group, the moulded flip-flop group showed a significant improvement in the primary outcome measure of the FHSQ pain domain (adjusted mean difference 8.36 points, 95 % CI 5.58 to 13.27, p footwear and six (footwear group = 4) were lost to follow up. Our results demonstrate that flip-flop footwear with a moulded foot-bed can have a significant effect on foot pain, function and foot health and might be a valuable adjunct therapy for people with foot pain. ACTRN12614000933651 . Retrospectively registered: 01/09/2014.

  5. Imaging of Charcot foot

    International Nuclear Information System (INIS)

    Erlemann, Rainer; Schmitz, Annette

    2014-01-01

    The onset of a Charcot foot ist a feared complication of a long lasting diabetes mellitus. A peripheral neuropathy and continuous weight bearing of the foot subsequent to repeated traumas depict the conditions. There exist three types of a Charcot foot, an atrophic, a hypertophic and a mixed type. In early stages a differentiation from osteoarthritis is difficult. Subluxation or luxation within the Lisfranc's joint is typical. The joints of the foot could rapidly and extensively be destroyed or may present the morphology of a 'superosteoarthritis'. Often, soft tissue infections or osteomyelitis evolve from ulcers of the skin as entry points. Diagnosis of osteomyelitis necessitate MR imaging as plain radiography offers only low sensitivity for detection of an osteomyelitis. The existence of periosteal reactions is not a proof for osteomyelitis. Bone marrow edema and soft tissue edema also appear in a non infected Charcot foot. The range of soft tissue infections goes from cellulitis over phlegmon to abscesses. The ghost sign is the most suitable diagnostic criterion for osteomyelitis. In addition, the penumbra sign or the existence of a sinus tract between a skin ulcer and the affected bone may be helpful. (orig.)

  6. Starting off on the right foot: strong right-footers respond faster with the right foot to positive words and with the left foot to negative words.

    Science.gov (United States)

    de la Vega, Irmgard; Graebe, Julia; Härtner, Leonie; Dudschig, Carolin; Kaup, Barbara

    2015-01-01

    Recent studies have provided evidence for an association between valence and left/right modulated by handedness, which is predicted by the body-specificity hypothesis (Casasanto, 2009) and also reflected in response times. We investigated whether such a response facilitation can also be observed with foot responses. Right-footed participants classified positive and negative words according to their valence by pressing a key with their left or right foot. A significant interaction between valence and foot only emerged in the by-items analysis. However, when dividing participants into two groups depending on the strength of their footedness, an interaction between valence and left/right was observed for strong right-footers, who responded faster with the right foot to positive words, and with the left foot to negative words. No interaction emerged for weak right-footers. The results strongly support the assumption that fluency lies at the core of the association between valence and left/right.

  7. Diabetic Foot - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Diabetic Foot URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Diabetic Foot - Multiple Languages To use the sharing features on ...

  8. Dynamics of deforming drops

    OpenAIRE

    Bouwhuis, W.

    2015-01-01

    Liquid drops play a dominant role in numerous industrial applications, such as spray coating, spray painting, inkjet printing, lithography processes, and spraying/sprinkling in agriculture or gardening. In all of these examples, the generation, flight, impact, and spreading of drops are separate stages of the corresponding industrial processes, which are all thoroughly studied for many years. This thesis focuses on drop dynamics, impact phenomena, Leidenfrost drops, and pouring flows. Based o...

  9. Health education programmes to improve foot self-care practices and foot problems among older people with diabetes: a systematic review.

    Science.gov (United States)

    Ahmad Sharoni, Siti Khuzaimah; Minhat, Halimatus Sakdiah; Mohd Zulkefli, Nor Afiah; Baharom, Anisah

    2016-09-01

    To assess the effectiveness of health education programmes to improve foot self-care practices and foot problems among older people with diabetes. The complications of diabetes among older people are a major health concern. Foot problems such as neuropathy, ulcer and ultimately amputation are a great burden on older people with diabetes. Diabetes foot education programmes can influence the behaviour of older people in practising foot self-care and controlling the foot problems. However, the educational approaches used by the educators are different. Therefore, it is important to assess the education programmes from various evidence-based practices. Six databases, EBSCOhost medical collections (MEDLINE, CINAHL, Psychology and Behavioral Sciences Collection), SAGE, Wiley Online Library, ScienceDirect, SpringerLink and Web of Science, were used to search for articles published from January 2000 to March 2015. The search was based on the inclusion criteria and keywords including 'foot', 'care' and 'diabetes'. Fourteen studies were assessed and reviewed in the final stage. Health education programmes varied according to their design, setting, approach, outcome measured and results. Foot assessment, verbal and written instructions and discussion were proved to improve the foot self-care and foot problems. Subsequent follow-ups and evaluations had a significant effect. An improvement was observed in foot self-care scores and foot problems (such as neuropathy, foot disability, lesion, ulcer, tinea pedis and callus grade) after implementation of the health education programme. The findings of this study support the claim that a health education programme increases the foot self-care scores and reduces the foot problems. However, there were certain methodological concerns in the reviewed articles, indicating the need for further evaluation. In future, researchers and practitioners must implement a vigorous education programme focusing on diabetes foot self-care among the

  10. Scanning drop sensor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian; Xiang, Chengxiang; Gregoire, John

    2017-05-09

    Electrochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  11. PIP breast implants: rupture rate and correlation with breast cancer.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Cornacchia, I; Vincenti, L; Ranieri, V; Cirili, A; Rella, L; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years' experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture. 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed. The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated.

  12. Diabetes: Good Diabetes Management and Regular Foot Care Help Prevent Severe Foot Sores

    Science.gov (United States)

    Amputation and diabetes: How to protect your feet Good diabetes management and regular foot care help prevent severe foot sores that ... and may require amputation. By Mayo Clinic Staff Diabetes complications can include nerve damage and poor blood ...

  13. Coralline hydroxyapatite: a bone graft alternative in foot and ankle surgery.

    Science.gov (United States)

    Rahimi, F; Maurer, B T; Enzweiler, M G

    1997-01-01

    The use of coralline hydroxyapatite has become a viable bone grafting alternative. Its efficacy has been well established through multiple human and animal studies. Coralline hydroxyapatite enhances osteogenesis by providing a biocompatible lattice for the passage and assembly of vascular, fibroblastic, and osteoblastic tissues. It also provides support for surrounding osseous structures. The uses of this material are expanding into the realm of foot and ankle surgery. Its consideration as an appropriate bone graft substitute as well as multiple case studies demonstrating its surgical applicability are discussed. The implants utilized at Thorek Hospital and Medical Center over the past eight years, with an average follow-up of three and one-half years, have proven to be a valuable resource for augmentation where an osseous defect has occurred.

  14. Foot Conditions among Homeless Persons: A Systematic Review

    Science.gov (United States)

    To, Matthew J.; Brothers, Thomas D.; Van Zoost, Colin

    2016-01-01

    Introduction Foot problems are common among homeless persons, but are often overlooked. The objectives of this systematic review are to summarize what is known about foot conditions and associated interventions among homeless persons. Methods A literature search was conducted on MEDLINE (1966–2016), EMBASE (1947–2016), and CINAHL (1982–2016) and complemented by manual searches of reference lists. Articles that described foot conditions in homeless persons or associated interventions were included. Data were independently extracted on: general study characteristics; participants; foot assessment methods; foot conditions and associated interventions; study findings; quality score assessed using the Downs and Black checklist. Results Of 333 articles screened, 17 articles met criteria and were included in the study. Prevalence of any foot problem ranged from 9% to 65% across study populations. Common foot-related concerns were corns and calluses, nail pathologies, and infections. Foot pathologies related to chronic diseases such as diabetes were identified. Compared to housed individuals across studies, homeless individuals were more likely to have foot problems including tinea pedis, foot pain, functional limitations with walking, and improperly-fitting shoes. Discussion Foot conditions were highly prevalent among homeless individuals with up to two thirds reporting a foot health concern, approximately one quarter of individuals visiting a health professional, and one fifth of individuals requiring further follow-up due to the severity of their condition. Homeless individuals often had inadequate foot hygiene practices and improperly-fitting shoes. These findings have service provision and public health implications, highlighting the need for evidence-based interventions to improve foot health in this population. An effective interventional approach could include optimization of foot hygiene and footwear, provision of comprehensive medical treatment, and

  15. Foot Conditions among Homeless Persons: A Systematic Review.

    Science.gov (United States)

    To, Matthew J; Brothers, Thomas D; Van Zoost, Colin

    2016-01-01

    Foot problems are common among homeless persons, but are often overlooked. The objectives of this systematic review are to summarize what is known about foot conditions and associated interventions among homeless persons. A literature search was conducted on MEDLINE (1966-2016), EMBASE (1947-2016), and CINAHL (1982-2016) and complemented by manual searches of reference lists. Articles that described foot conditions in homeless persons or associated interventions were included. Data were independently extracted on: general study characteristics; participants; foot assessment methods; foot conditions and associated interventions; study findings; quality score assessed using the Downs and Black checklist. Of 333 articles screened, 17 articles met criteria and were included in the study. Prevalence of any foot problem ranged from 9% to 65% across study populations. Common foot-related concerns were corns and calluses, nail pathologies, and infections. Foot pathologies related to chronic diseases such as diabetes were identified. Compared to housed individuals across studies, homeless individuals were more likely to have foot problems including tinea pedis, foot pain, functional limitations with walking, and improperly-fitting shoes. Foot conditions were highly prevalent among homeless individuals with up to two thirds reporting a foot health concern, approximately one quarter of individuals visiting a health professional, and one fifth of individuals requiring further follow-up due to the severity of their condition. Homeless individuals often had inadequate foot hygiene practices and improperly-fitting shoes. These findings have service provision and public health implications, highlighting the need for evidence-based interventions to improve foot health in this population. An effective interventional approach could include optimization of foot hygiene and footwear, provision of comprehensive medical treatment, and addressing social factors that lead to increased risk

  16. Scanning drop sensor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian; Xiang, Chengxiang; Gregoire, John M.; Shinde, Aniketa A.; Guevarra, Dan W.; Jones, Ryan J.; Marcin, Martin R.; Mitrovic, Slobodan

    2017-05-09

    Electrochemical or electrochemical and photochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  17. In-hospital costs of diabetic foot disease treated by a multidisciplinary foot team

    NARCIS (Netherlands)

    Rinkel, Willem D.; Luiten, Jacky; van Dongen, Jelle; Kuppens, Bram; Van Neck, Johan W.; Polinder, Suzanne; Castro Cabezas, Manuel; Coert, J. Henk

    2017-01-01

    Background The diabetic foot imposes significant burden on healthcare systems. Obtaining knowledge on the extent of the costs of diabetic foot ulcers (DFUs) is of value to health care researchers investigating cost-effectiveness of interventions that prevent these costly complications. Objectives To

  18. Assessment of foot perfusion in patients with a diabetic foot ulcer.

    Science.gov (United States)

    Forsythe, Rachael O; Hinchliffe, Robert J

    2016-01-01

    Assessment of foot perfusion is a vital step in the management of patients with diabetic foot ulceration, in order to understand the risk of amputation and likelihood of wound healing. Underlying peripheral artery disease is a common finding in patients with foot ulceration and is associated with poor outcomes. Assessment of foot perfusion should therefore focus on identifying the presence of peripheral artery disease and to subsequently estimate the effect this may have on wound healing. Assessment of perfusion can be difficult because of the often complex, diffuse and distal nature of peripheral artery disease in patients with diabetes, as well as poor collateralisation and heavy vascular calcification. Conventional methods of assessing tissue perfusion in the peripheral circulation may be unreliable in patients with diabetes, and it may therefore be difficult to determine the extent to which poor perfusion contributes to foot ulceration. Anatomical data obtained on cross-sectional imaging is important but must be combined with measurements of tissue perfusion (such as transcutaneous oxygen tension) in order to understand the global and regional perfusion deficit present in a patient with diabetic foot ulceration. Ankle-brachial pressure index is routinely used to screen for peripheral artery disease, but its use in patients with diabetes is limited in the presence of neuropathy and medial arterial calcification. Toe pressure index may be more useful because of the relative sparing of pedal arteries from medial calcification but may not always be possible in patients with ulceration. Fluorescence angiography is a non-invasive technique that can provide rapid quantitative information about regional tissue perfusion; capillaroscopy, iontophoresis and hyperspectral imaging may also be useful in assessing physiological perfusion but are not widely available. There may be a future role for specialized perfusion imaging of these patients, including magnetic resonance

  19. The diabetic foot

    OpenAIRE

    Nabuurs-Franssen, M.H.

    2005-01-01

    The diabetic foot presents a complex interplay of neuropathic, macrovascular, and microvascular disease on an abnormal metabolic background, complicated by an increased susceptibility to mechanical, thermal, and chemical injury and decreased healing ability. The abnormalities of diabetes, once present, are not curable. But most severe foot abnormalities in the diabetic are due to neglect of injury and are mostly preventable. The physician must ensure that the diabetic patient learns the princ...

  20. Foot-and-mouth disease

    DEFF Research Database (Denmark)

    Belsham, Graham; Charleston, Bryan; Jackson, Terry

    2009-01-01

    Foot-and-mouth disease is an economically important, highly contagious, disease of cloven-hoofed animals characterized by the appearance of vesicles (blisters) on the feet and in and around the mouth. The causative agent, foot-and-mouth disease virus, was the first mammalian virus to be discovered...

  1. 49 CFR 214.115 - Foot protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Foot protection. 214.115 Section 214.115... protection. (a) The railroad or railroad contractor shall require railroad bridge workers to wear foot protection equipment when potential foot injury may result from impact, falling or flying objects, electrical...

  2. The Comparison of two models of marker – placement for identifying the rear foot angle in normal people with and without shoes during the stance phase of walking

    Directory of Open Access Journals (Sweden)

    2016-09-01

    Full Text Available Objective: The purpose of this study was to compare the two models of marker placement for identifying of rear foot angle in normal people with and without shoes during the different stage of stance phase of walking. Methods: Fifteen male students in Birjand University were selected based on Navicular Drop Index. After marker placement based on Clarke and Nigg models, the rear foot angle were recorded with two-dimensional analysis (Panasonic Camera from behind position while subjects walked with 1.7 m/s on a treadmill with and without shoes. For statistical analysis, independent samples t-test was used (p≤0.05. Results: The Results showed a significant difference in rear foot angle during the stance phase between the two models of Clarke and Nigg during walking with and without shoes (p≤0.001. Conclusion: Based on the results of the present study, due to their specific features care must be considered when using any of these two models to investigate the angular kinematics of the foot.

  3. Males that drop a sexually selected weapon grow larger testes.

    Science.gov (United States)

    Joseph, Paul N; Emberts, Zachary; Sasson, Daniel A; Miller, Christine W

    2018-01-01

    Costly sexually selected weapons are predicted to trade off with postcopulatory traits, such as testes. Although weapons can be important for achieving access to females, individuals of some species can permanently drop (i.e. autotomize) their weapons, without regeneration, to escape danger. We capitalized on this natural behavior to experimentally address whether the loss of a sexually selected weapon leads to increased testes investment in the leaf-footed cactus bug, Narnia femorata Stål (Hemiptera: Coreidae). In a second experiment, we measured offspring production for males that lost a weapon during development. As predicted, males that dropped a hind limb during development grew significantly larger testes than the control treatments. Hind-limb autotomy did not result in the enlargement of other nearby traits. Our results are the first to experimentally demonstrate that males compensate for natural weapon loss by investing more in testes. In a second experiment we found that females paired with males that lost a hind limb had 40% lower egg hatching success than females paired with intact males, perhaps because of lower mating receptivity to males with a lost limb. Importantly, in those cases where viable offspring were produced, males missing a hind limb produced 42% more offspring than males with intact limbs. These results suggest that the loss of a hind-limb weapon can, in some cases, lead to greater fertilization success. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.

  4. Foot preferences during resting in wildfowl and waders.

    Science.gov (United States)

    Randler, Christoph

    2007-03-01

    Footedness in birds has been reported, e.g., in parrots and chickens, but the direction of footedness remained unclear. Is a bird left-footed because it uses its left foot for holding and handling food, or is it right-footed because it uses the right foot for stabilisation and balancing while perching? In 2004 and 2006 I examined footedness in wildfowl and waders while the birds were performing a single task: roosting on the ground on one foot. Avocet (Recurvirostra avosetta), northern shoveller (Anas clypeata), oystercatcher (Haematopus ostralegus), and Eurasian curlew (Numenius arquata) were right-footed. Another 21 species did not show any significant foot preferences. This study provides some evidence that asymmetries in preferential foot use in birds may be triggered by a preference during postural control.

  5. Nineteen-Foot Diameter Explosively Driven Blast Simulator; TOPICAL

    International Nuclear Information System (INIS)

    VIGIL, MANUEL G.

    2001-01-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels

  6. Impact of an implanted neuroprosthesis on community ambulation in incomplete SCI.

    Science.gov (United States)

    Lombardo, Lisa M; Kobetic, Rudolf; Pinault, Gilles; Foglyano, Kevin M; Bailey, Stephanie N; Selkirk, Stephen; Triolo, Ronald J

    2018-03-01

    Test the effect of a multi-joint control with implanted electrical stimulation on walking after spinal cord injury (SCI). Single subject research design with repeated measures. Hospital-based biomechanics laboratory and user assessment of community use. Female with C6 AIS C SCI 30 years post injury. Lower extremity muscle activation with an implanted pulse generator and gait training. Walking speed, maximum distance, oxygen consumption, upper extremity (UE) forces, kinematics and self-assessment of technology. Short distance walking speed at one-year follow up with or without stimulation was not significantly different from baseline. However, average walking speed was significantly faster (0.22 m/s) with stimulation over longer distances than volitional walking (0.12 m/s). In addition, there was a 413% increase in walking distance from 95 m volitionally to 488 m with stimulation while oxygen consumption and maximum upper extremity forces decreased by 22 and 16%, respectively. Stimulation also produced significant (P ≤ 0.001) improvements in peak hip and knee flexion, ankle angle at foot off and at mid-swing. An implanted neuroprosthesis enabled a subject with incomplete SCI to walk longer distances with improved hip and knee flexion and ankle dorsiflexion resulting in decreased oxygen consumption and UE support. Further research is required to determine the robustness, generalizability and functional implications of implanted neuroprostheses for community ambulation after incomplete SCI.

  7. Introduction of hind foot coronal alignment view

    International Nuclear Information System (INIS)

    Moon, Il Bong; Jeon, Ju Seob; Yoon, Kang Cheol; Choi, Nam Kil; Kim, Seung Kook

    2006-01-01

    Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hind foot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hind foot coronal alignment view. Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. Both feet stood on a radiolucent platform with equal weight on both feet. Both feet are located foot axis longitudinal perpendicular to the platform. Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. The x-ray beam is angled down approximately 15 .deg. to 20 .deg. This image described tibial axis and medial, lateral tuberosity of calcaneus. Calcaneus do not rotated. The view is showed by talotibial joint space. Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hind foot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hind foot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hind foot and varus, valgus deformity of calcaneus

  8. The Relationship with Balance, Foot Posture, and Foot Size in School of Physical Education and Sports Students

    Science.gov (United States)

    Irez, Gonul Babayigit

    2014-01-01

    The aim of this study is to investigate the relationship of foot posture and foot size with balance. A hundred and thirteen healthy volunteers were recruited from undergraduate students (Male = 74, Female = 37, age range 18-22). The Foot Posture Index (FPI-6), anthropometric measurements, dynamic balance and static balance measurements were done…

  9. [Minor foot amputations in diabetic foot syndrome].

    Science.gov (United States)

    Biehl, C; Eckhard, M; Szalay, G; Heiss, C

    2016-10-01

    The treatment strategy for diabetic foot syndrome must take into account protective sensibility of the foot, open wounds, infection status, and the rules of septic bone surgery. Interventions are classified as elective, prophylactic, curative, or emergency. Amputations in the forefoot and midfoot region are performed as ray amputations (including metatarsal), which can often be carried out as "inner" amputations. Gentle tissue treatment mandatory because of greater risk of revision with re-amputation compared to classical amputation. Good demarcation of infection, acute osteomyelitis, osteolytic lesions, neurotropic ulcer, arterial and venous blood flow to the other toes, gangrene of other toes with metatarsal affection. Arterial occlusive disease, infection of neighboring areas, avoidable amputations, poorly healing ulcers on the lower leg. Primary dorsal approach; minimal incisional distance (5 cm) to minimize skin necrosis risk. Atraumatic preparation, minimize hemostasis to not compromise the borderline perfusion situation. In amputations, plantar skin preparation and longer seams placed as dorsal as possible, either disarticulated and maintain cartilage, or round the cortical metatarsal bone after resection. Diabetes control. Braun splint, mobilization in a shoe with forefoot decompression and hindfoot support, physiotherapy. Antibiotics based on resistance testing. If no complications, dressing change on postoperative day 1. Optimal wound drainage by lowering foot several times a day; drainage removal after 12-24 h. Insoles and footwear optimization. Amputations require continued attention and if necessary treatment to avoid sequelae. Insufficient treatment associated with recurrent ulceration and altered anatomy.

  10. The foot and ankle

    International Nuclear Information System (INIS)

    Berquist, T.H.

    1985-01-01

    Imaging of the foot and ankle can be difficult because of the complex anatomy. Familiarity with the bony and ligamentous anatomy is essential for proper evaluation of radiographic findings. Therefore, pertinent anatomy is discussed as it applies to specific injuries. Special views, tomography, arthrography, and other techniques may be indicated for complete evaluation of foot and ankle trauma

  11. Hanging drop crystal growth apparatus

    Science.gov (United States)

    Naumann, Robert J. (Inventor); Witherow, William K. (Inventor); Carter, Daniel C. (Inventor); Bugg, Charles E. (Inventor); Suddath, Fred L. (Inventor)

    1990-01-01

    This invention relates generally to control systems for controlling crystal growth, and more particularly to such a system which uses a beam of light refracted by the fluid in which crystals are growing to detect concentration of solutes in the liquid. In a hanging drop apparatus, a laser beam is directed onto drop which refracts the laser light into primary and secondary bows, respectively, which in turn fall upon linear diode detector arrays. As concentration of solutes in drop increases due to solvent removal, these bows move farther apart on the arrays, with the relative separation being detected by arrays and used by a computer to adjust solvent vapor transport from the drop. A forward scattering detector is used to detect crystal nucleation in drop, and a humidity detector is used, in one embodiment, to detect relative humidity in the enclosure wherein drop is suspended. The novelty of this invention lies in utilizing angular variance of light refracted from drop to infer, by a computer algorithm, concentration of solutes therein. Additional novelty is believed to lie in using a forward scattering detector to detect nucleating crystallites in drop.

  12. A review of the biomechanics of the diabetic foot

    NARCIS (Netherlands)

    van Schie, C. H. M.

    2005-01-01

    In general, diabetic foot ulcers result from abnormal mechanical loading of the foot, such as repetitive moderate pressure applied to the plantar aspect of the foot while walking. Diabetic peripheral neuropathy causes changes in foot structure, affecting foot function and subsequently leading to

  13. Spatial memory in nonhuman primates implanted with the subdural pharmacotherapy device.

    Science.gov (United States)

    Ludvig, Nandor; Tang, Hai M; Baptiste, Shirn L; Stefanov, Dimitre G; Kral, John G

    2015-06-01

    This study investigated the possible influence of the Subdural Pharmacotherapy Device (SPD) on spatial memory in 3 adult, male bonnet macaques (Macaca radiata). The device was implanted in and above the subdural/subarachnoid space and cranium overlaying the right parietal/frontal cortex: a circuitry involved in spatial memory processing. A large test chamber, equipped with four baited and four non-baited food-ports at different locations, was used: reaches into empty food ports were counted as spatial memory errors. In this study of within-subject design, before SPD implantation (control) the animals made mean 373.3 ± 114.9 (mean ± SEM) errors in the first spatial memory test session. This value dropped to 47.7 ± 18.4 by the 8th session. After SPD implantation and alternating cycles of transmeningeal saline delivery and local cerebrospinal fluid (CSF) drainage in the implanted cortex the spatial memory error count, with the same port locations, was 33.0 ± 12.2 during the first spatial memory test session, further decreasing to 5.7 ± 3.5 by the 8th post-implantation session (Pmemory performance, which in fact included at least one completely error-free session per animal over time. The study showed that complication-free implantation and use of the SPD over the parietal and frontal cortices for months leave spatial memory processes intact in nonhuman primates. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Avoiding foot complications in diabetes

    African Journals Online (AJOL)

    preceded by a foot ulcer.1,2 Every 30 seconds a lower limb or part of a lower limb is ... of foot ulcers are peripheral neuropathy, deformity, peripheral vascular disease and ... Repetitive stresses cause hyperkeratosis, followed by subcutaneous ...

  15. Foot, leg, and ankle swelling

    Science.gov (United States)

    Swelling of the ankles - feet - legs; Ankle swelling; Foot swelling; Leg swelling; Edema - peripheral; Peripheral edema ... Foot, leg, and ankle swelling is common when the person also: Is overweight Has a blood clot in the leg Is older Has ...

  16. The association between foot-care self efficacy beliefs and actual foot-care behaviour in people with peripheral neuropathy: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Swerissen Hal

    2009-02-01

    Full Text Available Abstract Background People with diabetes and peripheral neuropathy often do not implement the foot-care behavioural strategies that are suggested by many health professionals. The concept of self-efficacy has been shown to be an effective predictor of behaviour in many areas of health. This study investigated the relationships between foot-care self-efficacy beliefs, self-reported foot-care behaviour and history of diabetes-related foot pathology in people with diabetes and loss of protective sensation in their feet. Methods Ninety-six participants were included in this cross-sectional study undertaken in a regional city of Australia. All participants had diabetes and clinically diagnosed loss of protective sensation in their feet. The participants completed a self-report pen-paper questionnaire regarding foot-care self efficacy beliefs (the "Foot Care Confidence Scale" and two aspects of actual foot-care behaviour-preventative behaviour and potentially damaging behaviour. Pearson correlation coefficients were then calculated to determine the association between foot-care self-efficacy beliefs and actual reported foot-care behaviour. Multiple analysis of variance was undertaken to compare mean self-efficacy and behaviour subscale scores for those with a history of foot pathology, and those that did not. Results A small positive correlation (r = 0.2, p = 0.05 was found between self-efficacy beliefs and preventative behaviour. There was no association between self-efficacy beliefs and potentially damaging behaviour. There was no difference in self-efficacy beliefs in people that had a history of foot pathology compared to those that did not. Conclusion There is little association between foot-care self-efficacy beliefs and actual foot-care behaviour. The usefulness of measuring foot-care self-efficacy beliefs to assess actual self foot-care behaviour using currently available instruments is limited in people with diabetes and loss of protective

  17. Protocol for the Foot in Juvenile Idiopathic Arthritis trial (FiJIA: a randomised controlled trial of an integrated foot care programme for foot problems in JIA

    Directory of Open Access Journals (Sweden)

    Hendry Gordon J

    2009-06-01

    Full Text Available Abstract Background Foot and ankle problems are a common but relatively neglected manifestation of juvenile idiopathic arthritis. Studies of medical and non-medical interventions have shown that clinical outcome measures can be improved. However existing data has been drawn from small non-randomised clinical studies of single interventions that appear to under-represent the adult population suffering from juvenile idiopathic arthritis. To date, no evidence of combined therapies or integrated care for juvenile idiopathic arthritis patients with foot and ankle problems exists. Methods/design An exploratory phase II non-pharmacological randomised controlled trial where patients including young children, adolescents and adults with juvenile idiopathic arthritis and associated foot/ankle problems will be randomised to receive integrated podiatric care via a new foot care programme, or to receive standard podiatry care. Sixty patients (30 in each arm including children, adolescents and adults diagnosed with juvenile idiopathic arthritis who satisfy the inclusion and exclusion criteria will be recruited from 2 outpatient centres of paediatric and adult rheumatology respectively. Participants will be randomised by process of minimisation using the Minim software package. The primary outcome measure is the foot related impairment measured by the Juvenile Arthritis Disability Index questionnaire's impairment domain at 6 and 12 months, with secondary outcomes including disease activity score, foot deformity score, active/limited foot joint counts, spatio-temporal and plantar-pressure gait parameters, health related quality of life and semi-quantitative ultrasonography score for inflammatory foot lesions. The new foot care programme will comprise rapid assessment and investigation, targeted treatment, with detailed outcome assessment and follow-up at minimum intervals of 3 months. Data will be collected at baseline, 6 months and 12 months from baseline

  18. Pathophysiology diabetic foot ulcer

    Science.gov (United States)

    Syafril, S.

    2018-03-01

    Diabetes Mellitus (DM) is known to have many complications. Diabetes and its complications are rapidly becoming the world’s most significant cause of morbidity and mortality, and one of the most distressing is Diabetic Foot Ulcer (DFU). Chronic wound complications are a growing concern worldwide, and the effect is a warning to public health and the economy. The etiology of a DFU is multifaceted, and several components cause added together create a sufficient impact on ulceration: neuropathy, vasculopathy, immunopathy, mechanical stress, and neuroarthropathy. There are many classifications of the diabetic foot. About 50% of patients with foot ulcers due to DM present clinical signs of infection. It is essential to manage multifactorial etiology of DFU to get a good outcome.

  19. The clinical assessment study of the foot (CASF: study protocol for a prospective observational study of foot pain and foot osteoarthritis in the general population

    Directory of Open Access Journals (Sweden)

    Menz Hylton B

    2011-09-01

    Full Text Available Abstract Background Symptomatic osteoarthritis (OA affects approximately 10% of adults aged over 60 years. The foot joint complex is commonly affected by OA, yet there is relatively little research into OA of the foot, compared with other frequently affected sites such as the knee and hand. Existing epidemiological studies of foot OA have focussed predominantly on the first metatarsophalangeal joint at the expense of other joints. This three-year prospective population-based observational cohort study will describe the prevalence of symptomatic radiographic foot OA, relate its occurrence to symptoms, examination findings and life-style-factors, describe the natural history of foot OA, and examine how it presents to, and is diagnosed and managed in primary care. Methods All adults aged 50 years and over registered with four general practices in North Staffordshire, UK, will be invited to participate in a postal Health Survey questionnaire. Respondents to the questionnaire who indicate that they have experienced foot pain in the preceding twelve months will be invited to attend a research clinic for a detailed clinical assessment. This assessment will consist of: clinical interview; physical examination; digital photography of both feet and ankles; plain x-rays of both feet, ankles and hands; ultrasound examination of the plantar fascia; anthropometric measurement; and a further self-complete questionnaire. Follow-up will be undertaken in consenting participants by postal questionnaire at 18 months (clinic attenders only and three years (clinic attenders and survey participants, and also by review of medical records. Discussion This three-year prospective epidemiological study will combine survey data, comprehensive clinical, x-ray and ultrasound assessment, and review of primary care records to identify radiographic phenotypes of foot OA in a population of community-dwelling older adults, and describe their impact on symptoms, function and

  20. Assessment of auditory skills in 140 cochlear implant children using the EARS protocol.

    Science.gov (United States)

    Sainz, Manuel; Skarzynski, Henryk; Allum, John H J; Helms, Jan; Rivas, Adriana; Martin, Jane; Zorowka, Patrick Georg; Phillips, Lucy; Delauney, Joseph; Brockmeyer, Steffi Johanna; Kompis, Martin; Korolewa, Inna; Albegger, Klaus; Zwirner, Petra; Van De Heyning, Paul; D'Haese, Patrick

    2003-01-01

    Auditory performance of cochlear implant (CI) children was assessed with the Listening Progress Profile (LiP) and the Monosyllabic-Trochee-Polysyllabic-Word Test (MTP) following the EARS protocol. Additionally, the 'initial drop' phenomenon, a recently reported decrease of auditory performance occurring immediately after first fitting, was investigated. Patients were 140 prelingually deafened children from various clinics and centers worldwide implanted with a MEDEL COMBI 40/40+. Analysis of LiP data showed a significant increase after 1 month of CI use compared to preoperative scores (p < 0.01). No initial decrease was observed with this test. Analysis of MTP data revealed a significant improvement of word recognition after 6 months (p < 0.01), with a significant temporary decrease after initial fitting (p < 0.01). With both tests, children's auditory skills improved up to 2 years. Amount of improvement was negatively correlated with age at implantation. Copyright 2003 S. Karger AG, Basel

  1. Diabetic foot ulcers. Pathophysiology, assessment, and therapy.

    OpenAIRE

    Bowering, C. K.

    2001-01-01

    OBJECTIVE: To review underlying causes of diabetic foot ulceration, provide a practical assessment of patients at risk, and outline an evidence-based approach to therapy for diabetic patients with foot ulcers. QUALITY OF EVIDENCE: A MEDLINE search was conducted for the period from 1979 to 1999 for articles relating to diabetic foot ulcers. Most studies found were case series or small controlled trials. MAIN MESSAGE: Foot ulcers in diabetic patients are common and frequently lead to lower limb...

  2. Taiwanese adult foot shape classification using 3D scanning data.

    Science.gov (United States)

    Lee, Yu-Chi; Wang, Mao-Jiun

    2015-01-01

    This study classifies the foot shapes of Taiwanese using 3D foot scanning data from 2000 males and 1000 females. Nine foot dimensions relative to foot length and absolute measures in the common foot length categories were applied to compare the gender differences. Using foot breadth in % foot length (% FL), ball of foot length in % FL and arch height in % FL as feature parameters, three foot shape types for males and females can be classified. Significant gender differences were found in seven of the nine foot dimensions. Females had greater ball of foot length than males (0.2% FL). When comparing feet of the same foot length, males had greater breadth, girth and height dimensions than females, except for toe height. In addition, ethnic differences in foot shape were also observed. The findings can provide very useful information for building gender-specific shoe lasts and designing footwear insoles. 3D foot scanning data of 2000 males and 1000 females were classified into three different footshapes for males and females, respectively. Gender and ethnic differences on foot shape were also compared. The finding scan provide very useful information for gender-specific shoe last design and footwear production.

  3. Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates

    Science.gov (United States)

    Barrese, James C.; Aceros, Juan; Donoghue, John P.

    2016-04-01

    Objective. Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. Approach. We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. Main results. SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. Significance. These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does

  4. Vibration-Induced Climbing of Drops

    Science.gov (United States)

    Brunet, P.; Eggers, J.; Deegan, R. D.

    2007-10-01

    We report an experimental study of liquid drops moving against gravity, when placed on a vertically vibrating inclined plate, which is partially wetted by the drop. The frequency of vibrations ranges from 30 to 200 Hz, and, above a threshold in vibration acceleration, drops experience an upward motion. We attribute this surprising motion to the deformations of the drop, as a consequence of an up or down symmetry breaking induced by the presence of the substrate. We relate the direction of motion to contact angle measurements. This phenomenon can be used to move a drop along an arbitrary path in a plane, without special surface treatments or localized forcing.

  5. Implementation of foot thermometry plus mHealth to prevent diabetic foot ulcers: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Lazo-Porras, Maria; Bernabe-Ortiz, Antonio; Sacksteder, Katherine A; Gilman, Robert H; Malaga, German; Armstrong, David G; Miranda, J Jaime

    2016-04-19

    Diabetic foot neuropathy (DFN) is one of the most important complications of diabetes mellitus; its early diagnosis and intervention can prevent foot ulcers and the need for amputation. Thermometry, measuring the temperature of the feet, is a promising emerging modality for diabetic foot ulcer prevention. However, patient compliance with at-home monitoring is concerning. Delivering messages to remind patients to perform thermometry and foot care might be helpful to guarantee regular foot monitoring. This trial was designed to compare the incidence of diabetic foot ulcers (DFUs) between participants who receive thermometry alone and those who receive thermometry as well as mHealth (SMS and voice messaging) over a year-long study period. This is an evaluator-blinded, randomized, 12-month trial. Individuals with a diagnosis of type 2 diabetes mellitus, aged between 18-80 years, having a present dorsalis pedis pulse in both feet, are in risk group 2 or 3 using the diabetic foot risk classification system (as specified by the International Working Group on the Diabetic Foot), have an operating cell phone or a caregiver with an operating cell phone, and have the ability to provide informed consent will be eligible to participate in the study. Recruitment will be performed in diabetes outpatient clinics at two Ministry of Health tertiary hospitals in Lima, Peru. participants in both groups will receive education about foot care at the beginning of the study and they will be provided with a thermometry device (TempStat™). TempStat™ is a tool that captures a thermal image of the feet, which, depending on the temperature of the feet, shows different colors. In this study, if a participant notes a single yellow image or variance between one foot and the contralateral foot, they will be prompted to notify a nurse to evaluate their activity within the previous 2 weeks and make appropriate recommendations. In addition to thermometry, participants in the intervention arm

  6. [Foot reflexology massage: a clinical study].

    Science.gov (United States)

    Kesselring, A

    1999-02-01

    The aim of the study was to investigate the possible usefulness of foot reflexology on the recovery after a surgical intervention. 130 patients participated in the study. They underwent abdominal surgery under full anesthesia for different, but exclusively gynecological reasons. Foot reflexology investigated in this study was applied only for a few days for each patient. The following parameters were recorded: the subjective, self-assessed, general condition, pain intensity, movement of the bowels, micturition and sleep, beginning on the day before operation until day 10. Two other treatments served as controls, a simple massage of the foot or a personal conversation. The simple massage turned out to be a relaxing, positive experience, whereas foot reflexology had various effects, some of them were even negative. The conclusion was that foot reflexology is not recommended for acute, abdominal postsurgical situations in gynecology because it can occasionally trigger abdominal pain. This project is one of the few studies planned, conducted and performed by the nursing staff.

  7. Drop Tower Physics

    Science.gov (United States)

    Dittrich, William A.

    2014-01-01

    The drop towers of yesteryear were used to make lead shot for muskets, as described in "The Physics Teacher" in April 2012. However, modern drop towers are essentially elevators designed so that the cable can "break" on demand, creating an environment with microgravity for a short period of time, currently up to nine seconds at…

  8. Effects on foot external rotation of the modified ankle-foot orthosis on post-stroke hemiparetic gait.

    Science.gov (United States)

    Kim, Ha Jeong; Chun, Min Ho; Kim, Hong Min; Kim, Bo Ryun

    2013-08-01

    To evaluate the effects of heel-opened ankle foot orthosis (HOAFO) on hemiparetic gait after stroke, especially on external foot rotation, and to compare the effects of HOAFO with conventional plastic-AFO (pAFO) and barefoot during gait. This cross-over observational study involved 15 hemiparetic patients with external rotation of the affected foot. All subjects were able to walk independently, regardless of their usual use of a single cane, and had a less than fair-grade in ankle dorsiflexion power. Each patient was asked to walk in three conditions with randomized sequences: 1) barefoot, 2) with a pAFO, and 3) with an HOAFO. Their gait patterns were analyzed using a motion analysis system. Fifteen patients consisted of nine males and six females. On gait analysis, hip and foot external rotation were significantly greater in pAFO (-3.35° and -23.68°) than in barefoot and HOAFO conditions (pexternal rotation compared with pAFO; although there was no significant difference between HOAFO and barefoot walking. Walking speed and percentage of single limb support were significantly greater for HOAFO than in barefoot walking. HOAFO was superior to pAFO in reducing hip and foot external rotation during the stance phase in patients with post-stroke hemiparesis. HOAFO may, therefore, be useful in patients with excessive external rotation of the foot during conventional pAFO.

  9. Trends in lumber processing in the western United States. Part I: board foot Scribner volume per cubic foot of timber

    Science.gov (United States)

    Charles E. Keegan; Todd A. Morgan; Keith A. Blatner; Jean M. Daniels

    2010-01-01

    This article describes trends in board foot Scribner volume per cubic foot of timber for logs processed by sawmills in the western United States. Board foot to cubic foot (BF/CF) ratios for the period from 2000 through 2006 ranged from 3.70 in Montana to 5.71 in the Four Corners Region (Arizona, Colorado, New Mexico, and Utah). Sawmills in the Four Corners Region,...

  10. Narrative review: Diabetic foot and infrared thermography

    Science.gov (United States)

    Hernandez-Contreras, D.; Peregrina-Barreto, H.; Rangel-Magdaleno, J.; Gonzalez-Bernal, J.

    2016-09-01

    Diabetic foot is one of the major complications experienced by diabetic patients. An early identification and appropriate treatment of diabetic foot problems can prevent devastating consequences such as limb amputation. Several studies have demonstrated that temperature variations in the plantar region can be related to diabetic foot problems. Infrared thermography has been successfully used to detect complication related to diabetic foot, mainly because it is presented as a rapid, non-contact and non-invasive technique to visualize the temperature distribution of the feet. In this review, an overview of studies that relate foot temperature with diabetic foot problems through infrared thermography is presented. Through this research, it can be appreciated the potential of infrared thermography and the benefits that this technique present in this application. This paper also presents the different methods for thermogram analysis and the advantages and disadvantages of each one, being the asymmetric analysis the method most used so far.

  11. Foot burns: epidemiology and management.

    Science.gov (United States)

    Hemington-Gorse, S; Pellard, S; Wilson-Jones, N; Potokar, T

    2007-12-01

    This is a retrospective study of the epidemiology and management of isolated foot burns presenting to the Welsh Centre for Burns from January 1998 to December 2002. A total of 289 were treated of which 233 were included in this study. Approximately 40% were in the paediatric age group and the gender distribution varied dramatically for adults and children. In the adult group the male:female ratio was 3.5:1, however in the paediatric group the male:female ratio was more equal (1.6:1). Scald burns (65%) formed the largest group in children and scald (35%) and chemical burns (32%) in adults. Foot burns have a complication rate of 18% and prolonged hospital stay. Complications include hypertrophic scarring, graft loss/delayed healing and wound infection. Although isolated foot burns represent a small body surface area, over half require treatment as in patients to allow for initial aggressive conservative management of elevation and regular wound cleansing to avoid complications. This study suggests a protocol for the initial acute management of foot burns. This protocol states immediate referral of all foot burns to a burn centre, admission of these burns for 24-48 h for elevation, regular wound cleansing with change of dressings and prophylactic antibiotics.

  12. A prospective study of risk factors for foot ulceration: The West of Ireland Diabetes Foot Study.

    LENUS (Irish Health Repository)

    Hurley, L

    2013-09-25

    BackgroundThis is the first study to examine risk factors for diabetic foot ulceration in Irish general practice.AimTo determine the prevalence of established risk factors for foot ulceration in a community-based cohort, and to explore the potential for estimated glomerular filtration rate (eGFR) to act as a novel risk factor.DesignA prospective observational study.MethodsPatients with diabetes attending 12 (of 17) invited general practices were invited for foot screening. Validated clinical tests were carried out at baseline to assess for vascular and sensory impairment and foot deformity. Ulcer incidence was ascertained by patient self-report and medical record. Patients were re-assessed 18 months later. ResultsOf 828 invitees, 563 (68%) attended screening. On examination 23-25% had sensory dysfunction and 18-39% had evidence of vascular impairment. Using the Scottish Intercollegiate Guidelines Network risk stratification system we found the proportion at moderate and high risk of future ulceration to be 25% and 11% respectively. At follow-up 16\\/383 patients (4.2%) developed a new foot ulcer (annual incidence rate of 2.6%). We observed an increasing probability of abnormal vascular and sensory test results (pedal pulse palpation, doppler waveform assessment, 10g monofilament, vibration perception and neuropathy disability score) with declining eGFR levels. We were unable to show an independent association between new ulceration and reduced eGFR [Odds ratio 1.01; p=0.64].ConclusionsOur data show the extent of foot complications in a representative sample of diabetes patients in Ireland. Use of eGFR did not improve identification of patients at risk of foot ulceration.

  13. Welcome to Journal of Foot and Ankle Research: a new open access journal for foot health professionals

    Directory of Open Access Journals (Sweden)

    Borthwick Alan M

    2008-07-01

    Full Text Available Abstract Journal of Foot and Ankle Research (JFAR is a new, open access, peer-reviewed online journal that encompasses all aspects of policy, organisation, delivery and clinical practice related to the assessment, diagnosis, prevention and management of foot and ankle disorders. JFAR will cover a wide range of clinical subject areas, including diabetology, paediatrics, sports medicine, gerontology and geriatrics, foot surgery, physical therapy, dermatology, wound management, radiology, biomechanics and bioengineering, orthotics and prosthetics, as well the broad areas of epidemiology, policy, organisation and delivery of services related to foot and ankle care. The journal encourages submission from all health professionals who manage lower limb conditions, including podiatrists, nurses, physical therapists and physiotherapists, orthopaedists, manual therapists, medical specialists and general medical practitioners, as well as health service researchers concerned with foot and ankle care. All manuscripts will undergo open peer review, and all accepted manuscripts will be freely available on-line using the open access platform of BioMed Central.

  14. Drop "impact" on an airfoil surface.

    Science.gov (United States)

    Wu, Zhenlong

    2018-05-17

    Drop impact on an airfoil surface takes place in drop-laden two-phase flow conditions such as rain and icing, which are encountered by wind turbines or airplanes. This phenomenon is characterized by complex nonlinear interactions that manifest rich flow physics and pose unique modeling challenges. In this article, the state of the art of the research about drop impact on airfoil surface in the natural drop-laden two-phase flow environment is presented. The potential flow physics, hazards, characteristic parameters, droplet trajectory calculation, drop impact dynamics and effects are discussed. The most key points in establishing the governing equations for a drop-laden flow lie in the modeling of raindrop splash and water film. The various factors affecting the drop impact dynamics and the effects of drop impact on airfoil aerodynamic performance are summarized. Finally, the principle challenges and future research directions in the field as well as some promising measures to deal with the adverse effects of drop-laden flows on airfoil performance are proposed. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Foot and ankle problems in Thai monks.

    Science.gov (United States)

    Vaseenon, Tanawat; Wattanarojanaporn, Thongaek; Intharasompan, Piyapong; Theeraamphon, Nipon; Auephanviriyakul, Sansanee; Phisitkul, Phinit

    2015-01-01

    Foot and ankle problems in Thai monks have not been explored. This is an unshod population, and its members have a unique lifestyle living among others in our modern era. Beginning at their ordainment, they follow strict rules about barefoot walking, the amount of daily walking, and their sitting position, practices that theoretically can increase their risk of developing foot and ankle problems. To evaluate the prevalence ofcommon foot and ankle problems in Thai monks. A cross-sectional survey was conducted in combination with foot and ankle examinations of monks living in northern Thailand Foot morphology was examined using a Harris mat footprint. Results of the interviews and the foot and ankle examinations were evaluated. Two hundred and nine monks from 28 temples were included in this study. Common foot and ankle problems found included callosity (70.8%), toe deformities (18.2%), plantar fasciitis (13.4%), metatarsalgia (3.8%), and numbness (2.9%). Callosity and toe deformities were associated with prolonged barefoot walking over extended periods since ordainment (p < 0.05). The callosity was found on the forefoot (47.3%), lateral malleolus (40.7%), and heel (12%). Arch types were considered normal in 66.4% of cases, high in 21.6%, and low in 12%. No association was found between arch type and foot and ankle problems. Callosity and toe deformity were the most common foot and ankle problems found in Thai monks, especially those with prolonged period of barefoot walking and long-term duration ofordainment. The unique pattern of walking and sitting of Thai monks may have contributed to the development of those feet and ankle problems.

  16. Foot and ankle problems in Muay Thai kickboxers.

    Science.gov (United States)

    Vaseenon, Tanawat; Intharasompan, Piyapong; Wattanarojanapom, Thongaek; Theeraamphon, Nipon; Auephanviriyakul, Sansanee; Phisitkul, Phinit

    2015-01-01

    Muay Thai kickboxing is a common sport that uses the foot and ankle in fighting. Muay Thai kickboxing trainees usually receive training in Thailand Foot and ankle problems in this group ofpeople who usually train barefoot remain unexplored To evaluate the prevalence of common foot and ankle problems in Muay Thai kick boxers. The present study is a cross-sectional survey of Muay Thai kick boxers practicing in northern Thailand. Interviews were conducted and foot and ankle examinations were evaluated Foot morphology was examined using a Harris mat footprint. One hundred and twenty-three Muay Thai kickbox ersinnine training gyms were included in this study. Common foot and ankle problems found in the Muay Thai kick boxers were callosity (59%), gastrocnemius contracture (57%), toe deformities (49.3%), wounds (10%) and heel pain (9%). Callosity was most commonly found on the forefoot (77.5%), on the plantar first metatarsal (55.3%) and on the big toe (33.3%). An association was found between a tight heel cord and a history of foot injury with prolonged periods of weekly training. Toe deformities such as hallux rigidus (37.6%) were also associated with prolonged periods of training (p = 0.001). No correlation was found between type of foot arch and foot and ankle problems. Plantar forefoot callosities and wounds as well as toe deformities including tight heel cords are some of the foot and ankle problems commonly found in Muay Thai kick boxers. They are associated with prolonged periods of barefoot training. The unique pattern of training and of the kicks in Muay Thai might be a path mechanism, leading to the development of foot and ankle problems.

  17. [Effects of foot reflexology on essential hypertension patients].

    Science.gov (United States)

    Park, Hyoung-Sook; Cho, Gyoo-Yeong

    2004-08-01

    This study was to evaluate the effects of foot reflexology on blood pressure, serum lipids level and life satisfaction in essential hypertension patients. The research design used was a nonequivalent control group pretest-posttest design. Foot Reflexology was used as the experimental treatment from June 23rd, 2003 until August 31st, 2003. Thirty-four subjects were assigned to an experimental group(18) and control group(16). Foot Reflexology was administered twice a week for 6 weeks and self foot Reflexology was administered twice a week for 4 weeks on the experimental group. There was a significant decrease in systolic blood pressure but no significant decrease in diastolic pressure in the experimental group compared to the control group. The total cholesterol level in the experimental group compared to the control group was not significantly decreased after foot reflexology. However, the triglyceride level in the experimental group compared to the control group was significantly decreased after foot reflexology. On the other hand, high density lipoprotein and low density lipoprotein levels in the experimental group compared to the control group was not significantly decreased after foot reflexology. Life satisfaction in the experimental group compared to the control group was significantly improved after foot reflexology. The results proved that foot reflexology was an effective nursing intervention to decrease systolic pressure, and triglyceride but not for the blood cholesterol and to improve life satisfaction. Therefore, blood cholesterol should be further evaluated in a larger group of subjects and for a longer period. Further research is regarded as necessary to evaluate and to compare effects of self-foot reflexology and foot reflexology.

  18. COMPARISON OF GAIT USING A MULTIFLEX FOOT VERSUS A QUANTUM FOOT IN KNEE DISARTICULATION AMPUTEES

    NARCIS (Netherlands)

    BOONSTRA, AM; FIDLER, [No Value; SPITS, GMA; HOF, AL; Tuil, P.

    The subjective responses and gait patterns of unilateral knee disarticulation amputees wearing prostheses fitted first with the Multiflex foot and then with the Quantum foot were studied. Nine amputees were included in the trial. A questionnaire asked the amputees about their preference for one of

  19. Effects of kinesiotaping on foot posture in participants with pronated foot: a quasi-randomised, double-blind study.

    Science.gov (United States)

    Luque-Suarez, Alejandro; Gijon-Nogueron, Gabriel; Baron-Lopez, Francisco Javier; Labajos-Manzanares, Maria Teresa; Hush, Julia; Hancock, Mark Jonathan

    2014-03-01

    To investigate whether kinesiotaping improves excessive foot pronation compared with sham kinesiotaping. Quasi-randomised, double-blind study. One primary care centre. One hundred and thirty participants were screened for inclusion. Sixty-eight participants with pronated feet [Foot Posture Index (FPI)≥ 6] were enrolled, and the follow-up rate was 100%. Participants were allocated into one of two groups: an experimental kinesiotaping group (KT1) and a sham taping group (KT2). Measures were collected by a blinded assessor at baseline, and 1 minute, 10 minutes, 60 minutes and 24 hours after taping. The primary outcome was total FPI score, and the secondary outcome was rear-foot FPI score. There were no significant differences in total FPI score between kinesiotaping and sham taping at any time point. Similarly, there were no significant differences in rear-foot FPI score, apart from at 60-minute follow-up when the difference between groups was significant (P=0.04) but the effect size was very small (0.85 points on the rear-foot FPI score between -6 and +6). Kinesiotaping does not correct foot pronation compared with sham kinesiotaping in people with pronated feet. Copyright © 2013 Chartered Society of Physiotherapy. All rights reserved.

  20. Comparison of plantar pressure on normal -footed vs. high arch-footed badminton players in two-way lunge

    Directory of Open Access Journals (Sweden)

    parvane bazipoor

    2017-03-01

    Full Text Available Background: Compared to the individuals with a normal arch structure, those with high or low arch can be at an increased risk of overuse injuries. The risk of overuse injury among athletes is high due, in part, to the repeated loading of the lower extremities. The current study aimed to determine if foot type (high-arched or normal results in differences in plantar pressure during two badminton-specific movements (right-reverse lunge and right-lateral lunge. Methods: Twenty badminton players (10 with normal feet and 10 with higharched feet completed five trials in both right-reverse and right-lateral lunge, while in-shoe pressure data were collected at 100 Hz. The peak pressure and mean pressure were analyzed among the subjects for five major anatomical regions of the foot, using the independent t test in SPSS version 20. The foot type was determined by the foot posture index (FPI (α<0.05. Results: Results showed that the plantar pressure characteristics of normal and high-arched feet were different; such that in high-arched feet, as compared to normal subjects, there were significantly fewer pressure strikes in the medial (P=0.010 and lateral (P=0.002 mid-foot in right-reverse lunge and this was significantly higher in forefoot (P=0.003 and toes (P=0.010. However, the peak (P=0.157 and mean (P=0.104 pressure in the heel was higher but not significant. In the right- lateral lunge, we found statistically lower peak pressure stroke for the lateral mid-foot (P=0.010 and forefoot (P=0.011; however, the mean pressure was lower in the lateral (P=0.010 and medial (P=0.040 mid-foot and forefoot (P=0.120, although it was not significant in the forefoot. Conclusion: Results showed that the medial longitudinal arch of the foot might cause pressure differences in the feet among the players with normal and higharched feet. As the results demonstrated, in high-arched feet, there are some regions where plantar pressure is higher and some where it is lower

  1. Vortex flow in acoustically levitated drops

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Z.L.; Xie, W.J. [Department of Applied Physics, Northwestern Polytechnical University, Xi' an 710072 (China); Wei, B., E-mail: bbwei@nwpu.edu.cn [Department of Applied Physics, Northwestern Polytechnical University, Xi' an 710072 (China)

    2011-08-29

    The internal flow of acoustically levitated water drops is investigated experimentally. This study reveals a kind of vortex flow which rotates in the meridional plane of the levitated drop. The magnitude of fluid velocity is nearly vanishing at the drop center, whereas it increases toward the free surface of a levitated drop until the maximum value of about 80 mm/s. A transition of streamline shapes from concentric circles to ellipses takes place at the distance of about 1.2 mm from the drop center. The fluid velocity distribution is plotted as a function of polar angle for seven characteristic streamlines. -- Highlights: → We experimentally observe the internal flow of acoustically levitated water drops. → We present a fascinating structure of vortex flow inside the levitated water drop. → This vortex flow rotates around the drop center in the meridional plane. → Velocity distribution information of this vortex flow is quantitatively analyzed.

  2. Vortex flow in acoustically levitated drops

    International Nuclear Information System (INIS)

    Yan, Z.L.; Xie, W.J.; Wei, B.

    2011-01-01

    The internal flow of acoustically levitated water drops is investigated experimentally. This study reveals a kind of vortex flow which rotates in the meridional plane of the levitated drop. The magnitude of fluid velocity is nearly vanishing at the drop center, whereas it increases toward the free surface of a levitated drop until the maximum value of about 80 mm/s. A transition of streamline shapes from concentric circles to ellipses takes place at the distance of about 1.2 mm from the drop center. The fluid velocity distribution is plotted as a function of polar angle for seven characteristic streamlines. -- Highlights: → We experimentally observe the internal flow of acoustically levitated water drops. → We present a fascinating structure of vortex flow inside the levitated water drop. → This vortex flow rotates around the drop center in the meridional plane. → Velocity distribution information of this vortex flow is quantitatively analyzed.

  3. Hand, Foot, and Mouth Disease

    Centers for Disease Control (CDC) Podcasts

    Hand, foot, and mouth disease is a contagious illness that mainly affects children under five. In this podcast, Dr. Eileen Schneider talks about the symptoms of hand, foot, and mouth disease, how it spreads, and ways to help protect yourself and your children from getting infected with the virus.

  4. What is the diabetic foot?

    African Journals Online (AJOL)

    increase in the complications related to diabetes as a result of this increasing ... A number of contributory factors work together to cause foot ... neuropathy, peripheral vascular disease, foot deformities, external ... it is usually a combination of problems rather than a single risk ... This results in increased oxidative stress.

  5. Diabetic Foot Complications Despite Successful Pancreas Transplantation.

    Science.gov (United States)

    Seo, Dong-Kyo; Lee, Ho Seong; Park, Jungu; Ryu, Chang Hyun; Han, Duck Jong; Seo, Sang Gyo

    2017-06-01

    It is known that successful pancreas transplantation enables patients with diabetes to maintain a normal glucose level without insulin and reduces diabetes-related complications. However, we have little information about the foot-specific morbidity in patients who have undergone successful pancreas transplantation. The purpose of this study was to investigate the prevalence and predisposing factors for foot complications after successful pancreas transplantation. This retrospective study included 218 patients (91 males, 127 females) who had undergone pancreas transplantation for diabetes. The mean age was 40.7 (range, 15-76) years. Diabetes type, transplantation type, body mass index, and diabetes duration before transplantation were confirmed. After pancreas transplantation, the occurrence and duration of foot and ankle complications were assessed. Twenty-two patients (10.1%) had diabetic foot complications. Fifteen patients (6.9%) had diabetic foot ulcer and 7 patients (3.2%) had Charcot arthropathy. Three patients had both diabetic foot ulcer and Charcot arthropathy. Three insufficiency fractures (1.4%) were included. Mean time of complications after transplantation was 18.5 (range, 2-77) months. Creatinine level 1 year after surgery was higher in the complication group rather than the noncomplication group ( P = .02). Complications of the foot and ankle still occurred following pancreas transplantation in patients with diabetes. Level III, comparative study.

  6. A review of the foot function index and the foot function index – revised

    Science.gov (United States)

    2013-01-01

    Background The Foot Function Index (FFI) is a self-report, foot-specific instrument measuring pain and disability and has been widely used to measure foot health for over twenty years. A revised FFI (FFI-R) was developed in response to criticism of the FFI. The purpose of this review was to assess the uses of FFI and FFI-R as were reported in medical and surgical literature and address the suggestions found in the literature to improve the metrics of FFI-R. Methods A systematic literature search of PubMed/Medline and Embase databases from October 1991 through December 2010 comprised the main sources of literature. To enrich the bibliography, the search was extended to BioMedLib and Scopus search engines and manual search methods. Search terms included FFI, FFI scores, FFI-R. Requirements included abstracts/full length articles, English-language publications, and articles containing the term "foot complaints/problems." Articles selected were scrutinized; EBM abstracted data from literature and collected into tables designed for this review. EBM analyzed tables, KJC, JM, RMS reviewed and confirmed table contents. KJC and JM reanalyzed the original database of FFI-R to improve metrics. Results Seventy-eight articles qualified for this review, abstracts were compiled into 12 tables. FFI and FFI-R were used in studies of foot and ankle disorders in 4700 people worldwide. FFI Full scale or the Subscales and FFI-R were used as outcome measures in various studies; new instruments were developed based on FFI subscales. FFI Full scale was adapted/translated into other cultures. FFI and FFI-R psychometric properties are reported in this review. Reanalysis of FFI-R subscales' confirmed unidimensionality, and the FFI-R questionnaires' response categories were edited into four responses for ease of use. Conclusion This review was limited to articles published in English in the past twenty years. FFI is used extensively worldwide; this instrument pioneered a quantifiable measure

  7. Bearing capacity of Skirt circular footing on sand

    Directory of Open Access Journals (Sweden)

    Amr Z. EL Wakil

    2013-09-01

    Full Text Available Skirts are used to improve the bearing capacity of shallow footings on sandy soil by constraining the soil beneath and containing the plastic flow of soil. They are used as an alternative to deep foundations in soils with low strength at the surface. As there has been available little work studying the performance of skirted foundation, we are performing eighteen laboratory experiments on circular steel footings of different diameters and different skirt lengths. The aim of these experiments is to shed some lights on the effects of skirts on the bearing capacity of shallow footings. The effects of skirt length and the relative density of sand on the ultimate load attained were investigated. From the accomplished laboratory tests, it was found that skirts improve appreciably the sustainability of shallow footings to applied load as they increase the ultimate load of shallow footings by some up to 6.25 times for the current study conditions and variables. The performance of skirted footing depends upon the relative density of sand and on the skirt length to footing diameter ratio. Skirts are more beneficial in case of footings on loose sand than in case of medium and dense sand.

  8. Clinical workflow for personalized foot pressure ulcer prevention.

    Science.gov (United States)

    Bucki, M; Luboz, V; Perrier, A; Champion, E; Diot, B; Vuillerme, N; Payan, Y

    2016-09-01

    Foot pressure ulcers are a common complication of diabetes because of patient's lack of sensitivity due to neuropathy. Deep pressure ulcers appear internally when pressures applied on the foot create high internal strains nearby bony structures. Monitoring tissue strains in persons with diabetes is therefore important for an efficient prevention. We propose to use personalized biomechanical foot models to assess strains within the foot and to determine the risk of ulcer formation. Our workflow generates a foot model adapted to a patient's morphology by deforming an atlas model to conform it to the contours of segmented medical images of the patient's foot. Our biomechanical model is composed of rigid bodies for the bones, joined by ligaments and muscles, and a finite element mesh representing the soft tissues. Using our registration algorithm to conform three datasets, three new patient models were created. After applying a pressure load below these foot models, the Von Mises equivalent strains and "cluster volumes" (i.e. volumes of contiguous elements with strains above a given threshold) were measured within eight functionally meaningful foot regions. The results show the variability of both location and strain values among the three considered patients. This study also confirms that the anatomy of the foot has an influence on the risk of pressure ulcer. Copyright © 2016. Published by Elsevier Ltd.

  9. Holographic interferometry for early diagnosisof children flat foot

    Directory of Open Access Journals (Sweden)

    Oleg Petrovich Bolshakov

    2015-03-01

    Full Text Available The article presents the first experience ofthe use of holographic interferometr y for earlydiagnosis of the flat foot in 4-5 years old children.13 patients were examined. The results of the clinicalexamination, plantography, and of the graphicalreconstruction of the form of the foot arch basedon the interferogramms of the prints on Pedilen areanalyzed. We revealed typical differences betweenthe form of the foot arches in children with flat foot and children with normal status. The use of the proposed method for early detection of congenital pes valgus and of the signs of “flexible flat” foot is being suggested.

  10. Repeatability of the Oxford Foot Model for Kinematic Gait Analysis of the Foot and Ankle

    NARCIS (Netherlands)

    van Hoeve, S.; Vos, J.; Weijers, P.; Verbruggen, J.; Willems, P.; Poeze, M.; Meijer, K.

    2015-01-01

    INTRODUCTION: Kinematic gait analysis via the multi-segmental Oxford foot model (OFM) may be a valuable addition to the biomechanical examination of the foot and ankle. The aim of this study is to assess the repeatability of the OFM in healthy subjects. METHODS: Nine healthy subjects, without a

  11. Challenging the foundations of the clinical model of foot function: further evidence that the root model assessments fail to appropriately classify foot function.

    Science.gov (United States)

    Jarvis, Hannah L; Nester, Christopher J; Bowden, Peter D; Jones, Richard K

    2017-01-01

    The Root model of normal and abnormal foot function remains the basis for clinical foot orthotic practice globally. Our aim was to investigate the relationship between foot deformities and kinematic compensations that are the foundations of the model. A convenience sample of 140 were screened and 100 symptom free participants aged 18-45 years were invited to participate. The static biomechanical assessment described by the Root model was used to identify five foot deformities. A 6 segment foot model was used to measure foot kinematics during gait. Statistical tests compared foot kinematics between feet with and without foot deformities and correlated the degree of deformity with any compensatory motions. None of the deformities proposed by the Root model were associated with distinct differences in foot kinematics during gait when compared to those without deformities or each other. Static and dynamic parameters were not correlated. Taken as part of a wider body of evidence, the results of this study have profound implications for clinical foot health practice. We believe that the assessment protocol advocated by the Root model is no longer a suitable basis for professional practice. We recommend that clinicians stop using sub-talar neutral position during clinical assessments and stop assessing the non-weight bearing range of ankle dorsiflexion, first ray position and forefoot alignments and movement as a means of defining the associated foot deformities. The results question the relevance of the Root assessments in the prescription of foot orthoses.

  12. Dynamic observation on changes of serum tumor markers levels after implantation of 125I radioactive seeds as treatment for several malignancies

    International Nuclear Information System (INIS)

    Sun Qihe; Yang Jiali; Gao Mingzhong

    2005-01-01

    Objective: To study the dynamic changes of serum levels of several tumor markers after implantation of 125 I seeds as treatment for breast, prostate and lung malignancies. Methods: Serum CA15-3 (in 48 cases of breast cancer), PSA (in 59 cases of prostate cancer) and CYFRA21-1 (in 59 cases of lung cancer) levels were measured with RIA both before and after implantation of 125 I seeds as treatment. Furthermore, dynamic observation on the serum markers levels was carried out every 3 months in ten patients in each category. Results: After treatment, levels of these markers dropped significantly. Dynamic observation revealed that in the 10 cases of breast cancer, the levels of CA15-3 dropped continually. However, in the 10 cases of prostatic cancer, the disease got worse and the PSA levels kept increasing. In the lung cancer group, the CYFRA21-1 levels rose markedly and all patients expired before 9 months. Conclusion: Dynamic observation on changes of serum tumor markers (CA15-3, PSA, CYFRA21-1) levels after 125 I seed implantation treatment was of definite prognostic value. (authors)

  13. A 1-year randomised controlled trial comparing zirconia versus metal-ceramic implant supported single-tooth restorations

    DEFF Research Database (Denmark)

    Hosseini, Mandana; Worsaae, Nils; Schiødt, Morten

    2011-01-01

    , by blinded assessors. RESULTS: One-year after loading, no patient dropped out and no implant failed, though one MC restoration had to be remade. The marginal bone loss was not significantly different between AC and MC restorations (AC: mean 0.08 mm, SD 0.25; MC: mean 0.10 mm, SD 0.17). Seven out of 10...

  14. Coalescence collision of liquid drops I: Off-center collisions of equal-size drops

    Directory of Open Access Journals (Sweden)

    Alejandro Acevedo-Malavé

    2011-09-01

    Full Text Available The Smoothed Particle Hydrodynamics method (SPH is used here to model off-center collisions of equal-size liquid drops in a three-dimensional space. In this study the Weber number is calculated for several conditions of the droplets dynamics and the velocity vector fields formed inside the drops during the collision process are shown. For the permanent coalescence the evolution of the kinetic and internal energy is shown and also the approaching to equilibrium of the resulting drop. Depending of the Weber number three possible outcomes for the collision of droplets is obtained: permanent coalescence, flocculation and fragmentation. The fragmentation phenomena are modeled and the formation of small satellite drops can be seen. The ligament that is formed follows the “end pinching” mechanism and it is transformed into a flat structure.

  15. CLINICOMICROBIOLOGICAL STUDY OF DIABETIC FOOT ULCERS

    Directory of Open Access Journals (Sweden)

    Nirmal Kumar Palaniappan

    2017-11-01

    Full Text Available BACKGROUND Type 2 diabetes mellitus is a chronic disease caused by a combination of lifestyle and genetic factors affecting all organs in the body. Foot ulcers are one of the common and serious long-term complications of diabetes leads to recurrent and chronic infections, which results in limb loss when treatment is delayed. The aim of this study is to find out the clinical outcome and microbiological profile in patients admitted with diabetic foot ulcers. MATERIALS AND METHODS The study conducted between November 2008 to November 2009 over 50 patients with history of foot ulceration and diabetes. 50 patients were admitted with diabetic foot ulcer over a period of one year between November 2008-2009. They were studied after getting written consent. A predesigned pro forma was used to get the parameters comprising age, gender, duration, type of diabetes mellitus, presence of neuropathy, nephropathy (serum creatinine, urine albumin, retinopathy (screening funduscopy by ophthalmologist. RESULTS Among 50 patients admitted and treated for diabetic foot ulcers with mean stay of 18 days, 29 (58% had complete healing on conservative management, 18 (36% underwent minor amputation (toes, 3 (6% had major amputation (below knee/above knee. No mortality among the study groups encountered. Gram-negative aerobes E. coli (36%, Pseudomonas (52%, Klebsiella (28%, Proteus vulgaris (20% and Acinetobacter (16% were most frequently isolated followed by gram-positive aerobes MRSA (14%, Enterococcus (6%, Strep pyogenes (4% and no anaerobic growth. CONCLUSION Diabetic foot infections are frequently polymicrobial and predominantly gram-negative aerobic bacteria at presentation. Multidrug resistance pseudomonas aeruginosa and MRSA in diabetic foot ulcer is at its emergence and life threatening. Initial aggressive multimodal approach with surgical intervention, culture specific and sensitive targeted combined broad-spectrum antibiotics decreases the morbidity and mortality

  16. "Self-Shaping" of Multicomponent Drops.

    Science.gov (United States)

    Cholakova, Diana; Valkova, Zhulieta; Tcholakova, Slavka; Denkov, Nikolai; Smoukov, Stoyan K

    2017-06-13

    In our recent study we showed that single-component emulsion drops, stabilized by proper surfactants, can spontaneously break symmetry and transform into various polygonal shapes during cooling [ Denkov Nature 2015 , 528 , 392 - 395 ]. This process involves the formation of a plastic rotator phase of self-assembled oil molecules beneath the drop surface. The plastic phase spontaneously forms a frame of plastic rods at the oil drop perimeter which supports the polygonal shapes. However, most of the common substances used in industry appear as mixtures of molecules rather than pure substances. Here we present a systematic study of the ability of multicomponent emulsion drops to deform upon cooling. The observed trends can be summarized as follows: (1) The general drop-shape evolution for multicomponent drops during cooling is the same as with single-component drops; however, some additional shapes are observed. (2) Preservation of the particle shape upon freezing is possible for alkane mixtures with chain length difference Δn ≤ 4; for greater Δn, phase separation within the droplet is observed. (3) Multicomponent particles prepared from alkanes with Δn ≤ 4 plastify upon cooling due to the formation of a bulk rotator phase within the particles. (4) If a compound, which cannot induce self-shaping when pure, is mixed with a certain amount of a compound which induces self-shaping, then drops prepared from this mixture can also self-shape upon cooling. (5) Self-emulsification phenomena are also observed for multicomponent drops. In addition to the three recently reported mechanisms of self-emulsification [ Tcholakova Nat. Commun. 2017 , ( 8 ), 15012 ], a new (fourth) mechanism is observed upon freezing for alkane mixtures with Δn > 4. It involves disintegration of the particles due to a phase separation of alkanes upon freezing.

  17. Increased plantar foot pressure in persons affected by leprosy

    NARCIS (Netherlands)

    Slim, Frederik J.; van Schie, Carine H.; Keukenkamp, Renske; Faber, William R.; Nollet, Frans

    2012-01-01

    Although foot pressure has been reported to be increased in people affected by leprosy, studies on foot pressure and its determinants are limited. Therefore, the aim was to assess barefoot plantar foot pressure and to identify clinical determinants of increased plantar foot pressure in leprosy

  18. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  19. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  20. Find an Orthopaedic Foot and Ankle MD/DO

    Science.gov (United States)

    ... All Site Content AOFAS / FootCareMD / Find a Surgeon Find a Foot & Ankle Orthopaedic Surgeon Page Content Who ... your prescribed treatment (surgical and/or non-surgical) ​ Find a Surgeon ​ Click here to find a foot ...

  1. Effect of forward/backward standing posture on foot shape

    NARCIS (Netherlands)

    Daanen, H.A.M.; Tan, T.K.; Punte, P.A.J.

    2000-01-01

    Foot length and breadth are generally used to determine the correct shoe size. An important question is whether foot length and foot breadth are dependent upon body posture. Therefore, the effect of leaning forward/backward on foot length and breadth is investigated in this study. Seven subjects

  2. A comparison of foot kinematics in people with normal- and flat-arched feet using the Oxford Foot Model.

    Science.gov (United States)

    Levinger, Pazit; Murley, George S; Barton, Christian J; Cotchett, Matthew P; McSweeney, Simone R; Menz, Hylton B

    2010-10-01

    Foot posture is thought to influence predisposition to overuse injuries of the lower limb. Although the mechanisms underlying this proposed relationship are unclear, it is thought that altered foot kinematics may play a role. Therefore, this study was designed to investigate differences in foot motion between people with normal- and flat-arched feet using the Oxford Foot Model (OFM). Foot posture in 19 participants was documented as normal-arched (n=10) or flat-arched (n=9) using a foot screening protocol incorporating measurements from weightbearing antero-posterior and lateral foot radiographs. Differences between the groups in triplanar motion of the tibia, rearfoot and forefoot during walking were evaluated using a three-dimensional motion analysis system incorporating a multi-segment foot model (OFM). Participants with flat-arched feet demonstrated greater peak forefoot plantar-flexion (-13.7° ± 5.6° vs -6.5° ± 3.7°; p=0.004), forefoot abduction (-12.9° ± 6.9° vs -1.8° ± 6.3°; p=0.002), and rearfoot internal rotation (10.6° ± 7.5° vs -0.2°± 9.9°; p=0.018) compared to those with normal-arched feet. Additionally, participants with flat-arched feet demonstrated decreased peak forefoot adduction (-7.0° ± 9.2° vs 5.6° ± 7.3°; p=0.004) and a trend towards increased rearfoot eversion (-5.8° ± 4.4° vs -2.5° ± 2.6°; p=0.06). These findings support the notion that flat-arched feet have altered motion associated with greater pronation during gait; factors that may increase the risk of overuse injury. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. 3D silicone rubber interfaces for individually tailored implants.

    Science.gov (United States)

    Stieghorst, Jan; Bondarenkova, Alexandra; Burblies, Niklas; Behrens, Peter; Doll, Theodor

    2015-01-01

    For the fabrication of customized silicone rubber based implants, e.g. cochlear implants or electrocortical grid arrays, it is required to develop high speed curing systems, which vulcanize the silicone rubber before it runs due to a heating related viscosity drop. Therefore, we present an infrared radiation based cross-linking approach for the 3D-printing of silicone rubber bulk and carbon nanotube based silicone rubber electrode materials. Composite materials were cured in less than 120 s and material interfaces were evaluated with scanning electron microscopy. Furthermore, curing related changes in the mechanical and cell-biological behaviour were investigated with tensile and WST-1 cell biocompatibility tests. The infrared absorption properties of the silicone rubber materials were analysed with fourier transform infrared spectroscopy in transmission and attenuated total reflection mode. The heat flux was calculated by using the FTIR data, emissivity data from the infrared source manufacturer and the geometrical view factor of the system.

  4. Clinical management of acute diabetic Charcot foot in Denmark

    DEFF Research Database (Denmark)

    Jansen, Rasmus Bo; Svendsen, Ole Lander; Kirketerp-Møller, Klaus

    2016-01-01

    INTRODUCTION: Charcot foot is a severe complication to diabetes mellitus and treatment involves several different clinical specialities. Our objective was to describe the current awareness, knowledge and treatment practices of Charcot foot among doctors who handle diabetic foot disorders. METHODS......: This study is based on a questionnaire survey sent out to healthcare professionals, primarily doctors, working with diabetic foot ulcers and Charcot feet in the public sector of the Danish healthcare system. RESULTS: The survey obtained a 52% response rate. A temperature difference of > 2 °C between the two...... and treatment practices of acute diabetic Charcot foot at diabetes foot clinics in Denmark. The responders seem to follow the international recommendations and guidelines on management of the acute diabetic Charcot foot, despite a lack of Danish guidelines. FUNDING: none. TRIAL REGISTRATION: not relevant....

  5. Isolation of a substance activating foot formation in hydra

    DEFF Research Database (Denmark)

    Grimmelikhuijzen, C J; Schaller, H C

    1977-01-01

    -forming potential of the tissue (2) It does not accelerate head regeneration, nor do the head factors of hydra discovered by Schaller (1973) and Berking (1977) accelerate foot regeneration. We propose that the foot-activating substance is a morphogen responsible for foot formation in hydra. The foot activator can...

  6. Dynamics of deforming drops

    NARCIS (Netherlands)

    Bouwhuis, W.

    2015-01-01

    Liquid drops play a dominant role in numerous industrial applications, such as spray coating, spray painting, inkjet printing, lithography processes, and spraying/sprinkling in agriculture or gardening. In all of these examples, the generation, flight, impact, and spreading of drops are separate

  7. Management of diabetic foot infections

    International Nuclear Information System (INIS)

    Jamil, M.; Amin, Z.; Chaudhary, T. H.; Shaheen, J.; Alvi, Z. R.

    2001-01-01

    Objective: To determine the infecting agent in diabetic food infection with the susceptibility pattern, and to evaluate the effect of wound infection, was culopathy, neuropathy and control of diabetes mellitus on the outcome of the patients. Design: A descriptive and observational study. Place and duration of study: Patients with diabetic foot, admitted in surgical unit 1, B.V. Hospital Bahawalpur, from April 1999 to April 2000, were included in this study. Subject and methods: A total of 60 known diabetic patients were studied, out of these 47 were males and 13 females. They were assessed for angiopathy, neuropathy and extend of foot involvement. Necessary investigations, including x-ray foot, ECG, serum urea and creatinine, pus culture and sensitivity were carried out. Diabetes was controlled on insulin of the basis of serum sugar and urine sugar chart and treated accordingly. Results: The most common age of foot involvement was between 40-70 years. Right side was involved more often than the left (67%: 37%). Most of the infections were due to staphylococcus (50%), pseudomonas (25%) and streptococci (8%). Antibiotic was started based on sensitivity report. Fluoro quinolone plus clindamycin was used in 50%, fluoro quinolone plus metronidazole in 20% and amoxicillin/clavulanate in 23%. Most of the patients (61.7%) were in grade iii or iv of Meggit wagner classification of diabetic foot. Three patients (5%) were treated by below knee amputations while 1.7% patient by above knee amputation. In twenty-four (40%) patients some form of to amputation/ray amputation had to be done,while 32(53.3%) patients had complete healing of would without any amputation. Mortality was 3.33% all the 4 patients (6.7%) who presented late, having uncontrolled diabetes, with angiopathy (absent foot pulses), neuropathy, infection of the foot (grade iii or above) resulted in major amputation sooner or latter. The 32 patients (53.3%) having controlled diabetes mellitus with no angiopathy or

  8. Cosmetic Foot Surgery: Fashion's Pandora's Box

    Science.gov (United States)

    ... Fashion’s Pandora’s Box? A A A | Print | Share Cosmetic Foot Surgery: Fashion’s Pandora’s Box? Foot and ankle ... extreme and imprudent as it may sound, the cosmetic surgery craze is not just for faces anymore— ...

  9. Growth factors for treating diabetic foot ulcers

    DEFF Research Database (Denmark)

    Martí-Carvajal, Arturo J; Gluud, Christian; Nicola, Susana

    2015-01-01

    following treatment for diabetic foot ulcers (RR 0.64, 95% CI 0.14 to 2.94; P value 0.56, low quality of evidence)Although 11 trials reported time to complete healing of the foot ulcers in people with diabetes , meta-analysis was not possible for this outcome due to the unique comparisons within each trial...... (minimum of one toe), complete healing of the foot ulcer, and time to complete healing of the diabetic foot ulcer as the primary outcomes. DATA COLLECTION AND ANALYSIS: Independently, we selected randomised clinical trials, assessed risk of bias, and extracted data in duplicate. We estimated risk ratios......BACKGROUND: Foot ulcers are a major complication of diabetes mellitus, often leading to amputation. Growth factors derived from blood platelets, endothelium, or macrophages could potentially be an important treatment for these wounds but they may also confer risks. OBJECTIVES: To assess...

  10. The effects of hip external rotator exercises and toe-spread exercises on lower extremity muscle activities during stair-walking in subjects with pronated foot.

    Science.gov (United States)

    Goo, Young-Mi; Kim, Da-Yeon; Kim, Tae-Ho

    2016-03-01

    [Purpose] The purpose of the present study was to examine the effects of toe-spread (TS) exercises and hip external rotator strengthening exercises for pronated feet on lower extremity muscle activities during stair-walking. [Subjects and Methods] The participants were 20 healthy adults with no present or previous pain, no past history of surgery on the foot or the ankle, and no foot deformities. Ten subjects performed hip external rotator strengthening exercises and TS exercises and the remaining ten subjects performed only TS exercises five times per week for four weeks. [Results] Less change in navicular drop height occurred in the group that performed hip external rotator exercises than in the group that performed only TS exercises. The group that performed only TS exercises showed increased abductor hallucis muscle activity during both stair-climbing and -descending, and the group that performed hip external rotator exercises showed increased muscle activities of the vastus medialis and abductor hallucis during stair-climbing and increased muscle activity of only the abductor hallucis during stair-descending after exercise. [Conclusion] Stair-walking can be more effectively performed if the hip external rotator muscle is strengthened when TS exercises are performed for the pronated foot.

  11. Repeatability of a 3D multi-segment foot model protocol in presence of foot deformities.

    Science.gov (United States)

    Deschamps, Kevin; Staes, Filip; Bruyninckx, Herman; Busschots, Ellen; Matricali, Giovanni A; Spaepen, Pieter; Meyer, Christophe; Desloovere, Kaat

    2012-07-01

    Repeatability studies on 3D multi-segment foot models (3DMFMs) have mainly considered healthy participants which contrasts with the widespread application of these models to evaluate foot pathologies. The current study aimed at establishing the repeatability of the 3DMFM described by Leardini et al. in presence of foot deformities. Foot kinematics of eight adult participants were analyzed using a repeated-measures design including two therapists with different levels of experience. The inter-trial variability was higher compared to the kinematics of healthy subjects. Consideration of relative angles resulted in the lowest inter-session variability. The absolute 3D rotations between the Sha-Cal and Cal-Met seem to have the lowest variability in both therapists. A general trend towards higher σ(sess)/σ(trial) ratios was observed when the midfoot was involved. The current study indicates that not only relative 3D rotations and planar angles can be measured consistently in patients, also a number of absolute parameters can be consistently measured serving as basis for the decision making process. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. The Influence of Foot-Strike Technique on the Neuromechanical Function of the Foot.

    Science.gov (United States)

    Kelly, Luke A; Farris, Dominic J; Lichtwark, Glen A; Cresswell, Andrew G

    2018-01-01

    The aim of this study was to investigate the influence of foot-strike technique on longitudinal arch mechanics and intrinsic foot muscle function during running. Thirteen healthy participants ran barefoot on a force-instrumented treadmill at 2.8 ms with a forefoot (FFS) and rearfoot (RFS; habitual) running technique, whereas kinetic, kinematic, and electromyographic data from the intrinsic foot muscles were collected simultaneously. The longitudinal arch was modeled as a single "midfoot" joint representing motion of the rearfoot (calcaneus) relative to the forefoot (metatarsals). An inverse dynamic analysis was performed to estimate joint moments generated about the midfoot, as well as mechanical work and power. The midfoot was more plantar flexed (higher arch) at foot contact when running with a forefoot running technique (RFS 0.2 ± 1.8 vs FFS 6.9 ± 3.0°, effect size (ES) = 2.7); however, there was no difference in peak midfoot dorsiflexion in stance (RFS -11.6 ± 3.0 vs FFS -11.4 ± 3.4°, ES = 0.63). When running with a forefoot technique, participants generated greater moments about the midfoot (27% increase, ES = 1.1) and performed more negative work (240% increase, ES = 2.2) and positive work (42% increase, ES = 1.1) about the midfoot. Average stance-phase muscle activation was greater for flexor digitorum brevis (20% increase, ES = 0.56) and abductor hallucis (17% increase, ES = 0.63) when running with a forefoot technique. Forefoot running increases loading about the longitudinal arch and also increases the mechanical work performed by the intrinsic foot muscles. These findings have substantial implications in terms of injury prevention and management for runners who transition from a rearfoot to a forefoot running technique.

  13. Electrohydrodynamics of a viscous drop with inertia.

    Science.gov (United States)

    Nganguia, H; Young, Y-N; Layton, A T; Lai, M-C; Hu, W-F

    2016-05-01

    Most of the existing numerical and theoretical investigations on the electrohydrodynamics of a viscous drop have focused on the creeping Stokes flow regime, where nonlinear inertia effects are neglected. In this work we study the inertia effects on the electrodeformation of a viscous drop under a DC electric field using a novel second-order immersed interface method. The inertia effects are quantified by the Ohnesorge number Oh, and the electric field is characterized by an electric capillary number Ca_{E}. Below the critical Ca_{E}, small to moderate electric field strength gives rise to steady equilibrium drop shapes. We found that, at a fixed Ca_{E}, inertia effects induce larger deformation for an oblate drop than a prolate drop, consistent with previous results in the literature. Moreover, our simulations results indicate that inertia effects on the equilibrium drop deformation are dictated by the direction of normal electric stress on the drop interface: Larger drop deformation is found when the normal electric stress points outward, and smaller drop deformation is found otherwise. To our knowledge, such inertia effects on the equilibrium drop deformation has not been reported in the literature. Above the critical Ca_{E}, no steady equilibrium drop deformation can be found, and often the drop breaks up into a number of daughter droplets. In particular, our Navier-Stokes simulations show that, for the parameters we use, (1) daughter droplets are larger in the presence of inertia, (2) the drop deformation evolves more rapidly compared to creeping flow, and (3) complex distribution of electric stresses for drops with inertia effects. Our results suggest that normal electric pressure may be a useful tool in predicting drop pinch-off in oblate deformations.

  14. Standardizing foot-type classification using arch index values.

    Science.gov (United States)

    Wong, Christopher Kevin; Weil, Rich; de Boer, Emily

    2012-01-01

    The lack of a reliable classification standard for foot type makes drawing conclusions from existing research and clinical decisions difficult, since different foot types may move and respond to treatment differently. The purpose of this study was to determine interrater agreement for foot-type classification based on photo-box-derived arch index values. For this correlational study with two raters, a sample of 11 healthy volunteers with normal to obese body mass indices was recruited from both a community weight-loss programme and a programme in physical therapy. Arch index was calculated using AutoCAD software from footprint photographs obtained via mirrored photo-box. Classification as high-arched, normal, or low-arched foot type was based on arch index values. Reliability of the arch index was determined with intra-class correlations; agreement on foot-type classification was determined using quadratic weighted kappa (κw). Average arch index was 0.215 for one tester and 0.219 for the second tester, with an overall range of 0.017 to 0.370. Both testers classified 6 feet as low-arched, 9 feet as normal, and 7 feet as high-arched. Interrater reliability for the arch index was ICC=0.90; interrater agreement for foot-type classification was κw=0.923. Classification of foot type based on arch index values derived from plantar footprint photographs obtained via mirrored photo-box showed excellent reliability in people with varying BMI. Foot-type classification may help clinicians and researchers subdivide sample populations to better differentiate mobility, gait, or treatment effects among foot types.

  15. Standardizing Foot-Type Classification Using Arch Index Values

    Science.gov (United States)

    Weil, Rich; de Boer, Emily

    2012-01-01

    ABSTRACT Purpose: The lack of a reliable classification standard for foot type makes drawing conclusions from existing research and clinical decisions difficult, since different foot types may move and respond to treatment differently. The purpose of this study was to determine interrater agreement for foot-type classification based on photo-box-derived arch index values. Method: For this correlational study with two raters, a sample of 11 healthy volunteers with normal to obese body mass indices was recruited from both a community weight-loss programme and a programme in physical therapy. Arch index was calculated using AutoCAD software from footprint photographs obtained via mirrored photo-box. Classification as high-arched, normal, or low-arched foot type was based on arch index values. Reliability of the arch index was determined with intra-class correlations; agreement on foot-type classification was determined using quadratic weighted kappa (κw). Results: Average arch index was 0.215 for one tester and 0.219 for the second tester, with an overall range of 0.017 to 0.370. Both testers classified 6 feet as low-arched, 9 feet as normal, and 7 feet as high-arched. Interrater reliability for the arch index was ICC=0.90; interrater agreement for foot-type classification was κw=0.923. Conclusions: Classification of foot type based on arch index values derived from plantar footprint photographs obtained via mirrored photo-box showed excellent reliability in people with varying BMI. Foot-type classification may help clinicians and researchers subdivide sample populations to better differentiate mobility, gait, or treatment effects among foot types. PMID:23729964

  16. Athlete's Foot: Clinical Update.

    Science.gov (United States)

    Ramsey, M L

    1989-10-01

    In brief: Athletes are particularly prone to athlete's foot because they are generally more exposed than others to conditions that encourage fungal growth, eg, communal showers and locker rooms. Diagnosis of athlete's foot rests on clinical suspicion and laboratory testing. Treatment may consist of topical antifungal agents and, for more resistant cases, oral griseofulvin. Preventive measures include keeping the feet dry, wearing nonocclusive leather shoes or sandals and absorbent cotton socks, and applying talcum or antifungal powder at least twice daily.

  17. Foot deformation during walking: differences between static and dynamic 3D foot morphology in developing feet.

    Science.gov (United States)

    Barisch-Fritz, Bettina; Schmeltzpfenning, Timo; Plank, Clemens; Grau, Stefan

    2014-01-01

    The complex functions of feet require a specific composition, which is progressively achieved by developmental processes. This development should take place without being affected by footwear. The aim of this study is to evaluate differences between static and dynamic foot morphology in developing feet. Feet of 2554 participants (6-16 years) were recorded using a new scanner system (DynaScan4D). Each foot was recorded in static half and full weight-bearing and during walking. Several foot measures corresponding to those used in last construction were calculated. The differences were identified by one-way ANOVA and paired Student's t-test. Static and dynamic values of each foot measure must be considered to improve the fit of footwear. In particular, footwear must account for the increase of forefoot width and the decrease of midfoot girth. Furthermore, the toe box should have a more rounded shape. The findings are important for the construction of footwear for developing feet.

  18. Infrared thermal imaging for automated detection of diabetic foot complications.

    Science.gov (United States)

    van Netten, Jaap J; van Baal, Jeff G; Liu, Chanjuan; van der Heijden, Ferdi; Bus, Sicco A

    2013-09-01

    Although thermal imaging can be a valuable technology in the prevention and management of diabetic foot disease, it is not yet widely used in clinical practice. Technological advancement in infrared imaging increases its application range. The aim was to explore the first steps in the applicability of high-resolution infrared thermal imaging for noninvasive automated detection of signs of diabetic foot disease. The plantar foot surfaces of 15 diabetes patients were imaged with an infrared camera (resolution, 1.2 mm/pixel): 5 patients had no visible signs of foot complications, 5 patients had local complications (e.g., abundant callus or neuropathic ulcer), and 5 patients had diffuse complications (e.g., Charcot foot, infected ulcer, or critical ischemia). Foot temperature was calculated as mean temperature across pixels for the whole foot and for specified regions of interest (ROIs). No differences in mean temperature >1.5 °C between the ipsilateral and the contralateral foot were found in patients without complications. In patients with local complications, mean temperatures of the ipsilateral and the contralateral foot were similar, but temperature at the ROI was >2 °C higher compared with the corresponding region in the contralateral foot and to the mean of the whole ipsilateral foot. In patients with diffuse complications, mean temperature differences of >3 °C between ipsilateral and contralateral foot were found. With an algorithm based on parameters that can be captured and analyzed with a high-resolution infrared camera and a computer, it is possible to detect signs of diabetic foot disease and to discriminate between no, local, or diffuse diabetic foot complications. As such, an intelligent telemedicine monitoring system for noninvasive automated detection of signs of diabetic foot disease is one step closer. Future studies are essential to confirm and extend these promising early findings. © 2013 Diabetes Technology Society.

  19. Efficient foot motor control by Neymar’s brain

    Directory of Open Access Journals (Sweden)

    Eiichi eNaito

    2014-08-01

    Full Text Available How very long-term (over many years motor skill training shapes internal motor representation remains poorly understood. We provide valuable evidence that the football brain of Neymar da Silva Santos Júnior (the Brasilian footballer recruits very limited neural resources in the motor-cortical foot regions during foot movements. We scanned his brain activity with a 3-tesla functional magnetic resonance imaging (fMRI while he rotated his right ankle at 1Hz. We also scanned brain activity when three other age-controlled professional footballers, two top-athlete swimmers and one amateur footballer performed the identical task. A comparison was made between Neymar’s brain activity with that obtained from the others. We found activations in the left medial-wall foot motor regions during the foot movements consistently across all participants. However, the size and intensity of medial-wall activity was smaller in the four professional footballers than in the three other participants, despite no difference in amount of foot movement. Surprisingly, the reduced recruitment of medial-wall foot motor regions became apparent in Neymar. His medial-wall activity was smallest among all participants with absolutely no difference in amount of foot movement. Neymar may efficiently control given foot movements probably by largely conserving motor-cortical neural resources. We discuss this possibility in terms of over-years motor skill training effect, use-dependent plasticity, and efficient motor control.

  20. Congenital and acquired foot disorders and their roentgenographic examination

    International Nuclear Information System (INIS)

    Weber, M.

    1986-01-01

    In addition to general radiologic aspects there are special orthopedic considerations have in interpretation of X-rays of the foot. This is especially important for the diagnosis of orthopedic foot diseases. In clubfoot X-rays are useful for therapeutic planning and control. Even in the first months of life radiographs can show important disturbances of growth of the foot and displacement of the bones of the tarsus. In other congenital foot deformities X-rays are important for diagnostic reasons: they prove luxations or skeletal deformities. The most important acquired foot disease is the pronating foot. X-rays do not only show the amount of joint damage and structural changes of bones but also allow to draw conclusions to be drawn about the causes of static and dynamic changes of the foot skeleton. Functional diagnostic radiological investigation is of decisive importance for evaluation of infantile pronating foot. X-rays allow the differentiation to be made between physiological and pathologic changes. Subtle radiographic investigation is essential while planning operative treatment in childhood, as in adults. (orig.) [de

  1. Foot Problems

    Science.gov (United States)

    ... early. Start OverDiagnosisThe cause may be FEMORAL ANTEVERSION, TIBIAL TORSION or METATARSUS ADDUCTUS, commonly called intoeing. Self CareSee your doctor. Start OverDiagnosisYou may have a STRESS FRACTURE of the bones in your foot. The pain ...

  2. Role of procalcitonin in infected diabetic foot ulcer.

    Science.gov (United States)

    Park, Jung Ho; Suh, Dong Hun; Kim, Hak Jun; Lee, Yong In; Kwak, Il Hoon; Choi, Gi Won

    2017-06-01

    Procalcitonin (PCT) has been recently accepted as a marker for diagnosing infection. The aim of the present study was to determine whether PCT levels are associated with infection severity of diabetic foot ulcers and whether PCT levels would be helpful to differentiate infected diabetic foot ulcer (IDFU) from IDFU associated with other infectious diseases (IDFU+O). We prospectively included 123 diabetic patients hospitalized for IDFU. Infection severity of diabetic foot ulcers was graded according to the Infectious Diseases Society of America-International Working Group on the Diabetic Foot clinical classification of diabetic foot infection. Chest radiograph, urinalysis, urine microscopy, urine culture, and blood cultures (if fever was present) were performed for all patients to diagnose other infectious diseases. Laboratory parameters were measured from blood venous samples. PCT (Spearman's ρ=0.338, Pdiabetic foot ulcers. However, only PCT levels could differentiate patients with associated infectious diseases from patients with no concomitant infection (area under the receiver-operator characteristic curve 0.869, Pdiabetic foot ulcers and PCT levels>0.59ng/mL in patients with IDFU may be associated with other systemic bacterial infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Foot-strike pattern and performance in a marathon.

    Science.gov (United States)

    Kasmer, Mark E; Liu, Xue-Cheng; Roberts, Kyle G; Valadao, Jason M

    2013-05-01

    To determine prevalence of heel strike in a midsize city marathon, if there is an association between foot-strike classification and race performance, and if there is an association between foot-strike classification and gender. Foot-strike classification (forefoot, midfoot, heel, or split strike), gender, and rank (position in race) were recorded at the 8.1-km mark for 2112 runners at the 2011 Milwaukee Lakefront Marathon. 1991 runners were classified by foot-strike pattern, revealing a heel-strike prevalence of 93.67% (n = 1865). A significant difference between foot-strike classification and performance was found using a Kruskal-Wallis test (P strike. No significant difference between foot-strike classification and gender was found using a Fisher exact test. In addition, subgroup analysis of the 126 non-heel strikers found no significant difference between shoe wear and performance using a Kruskal-Wallis test. The high prevalence of heel striking observed in this study reflects the foot-strike pattern of most mid-distance to long-distance runners and, more important, may predict their injury profile based on the biomechanics of a heel-strike running pattern. This knowledge can help clinicians appropriately diagnose, manage, and train modifications of injured runners.

  4. Minimally important change was estimated for the Manchester-Oxford Foot Questionnaire after foot/ankle surgery.

    Science.gov (United States)

    Dawson, Jill; Boller, Irene; Doll, Helen; Lavis, Grahame; Sharp, Robert; Cooke, Paul; Jenkinson, Crispin

    2014-06-01

    To ascertain the smallest amounts of change for the three Manchester-Oxford Foot Questionnaire (MOXFQ) domains that are likely to be clinically meaningful and beyond measurement error for conditions affecting the foot/ankle. Estimates were compared with those from the Short-Form 36 (SF-36). A prospective observational study of 671 consecutive patients undergoing foot or ankle surgery at an orthopedic hospital. Before and 9 months after surgery, patients completed the MOXFQ and SF-36; transition items (anchor) asked about perceived changes in foot/ankle pain or problems since the surgery. Four hundred ninety-one patients completed pre- and postoperative questionnaires. Anchor-based minimal clinically important change (MCIC) values were ~13 points for each of the MOXFQ Walking/standing (W/S), Pain, and Social Interaction (S-I) domains [and greater than the standard error of measurement (SEM)]. MCIC values for all SF-36 domains fell within the SEM. Between-group MCIDs for the MOXFQ were W/S, 16.2; Pain, 9.9; S-I, 9.3. Distribution-based minimal detectable change (MDC90) values for the MOXFQ were ~11, ~12, and ~16 score points for the W/S, Pain, and S-I scales, respectively. This article provides information for aiding the interpretability of MOXFQ outcomes data and for planning future studies. The SF-36 is not recommended as a primary outcome for foot/ankle surgery. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Capillary Thinning of Particle-laden Drops

    Science.gov (United States)

    Wagoner, Brayden; Thete, Sumeet; Jahns, Matt; Doshi, Pankaj; Basaran, Osman

    2015-11-01

    Drop formation is central in many applications such as ink-jet printing, microfluidic devices, and atomization. During drop formation, a thinning filament is created between the about-to-form drop and the fluid hanging from the nozzle. Therefore, the physics of capillary thinning of filaments is key to understanding drop formation and has been thoroughly studied for pure Newtonian fluids. The thinning dynamics is, however, altered completely when the fluid contains particles, the physics of which is not well understood. In this work, we explore the impact of solid particles on filament thinning and drop formation by using a combination of experiments and numerical simulations.

  6. Changes in Foot Shape after Long-Distance Running

    OpenAIRE

    Fukano, Mako; Iso, Shigeo

    2015-01-01

    Changes in foot shape during long-distance running may lead to alteration in shoe fit. However, little information is available on changes in foot shape following long-distance running. The purpose of this study was to assess changes in foot shape in experienced runners after a single long-distance run. Data from the right feet of 21 subjects were obtained using a foot scanner before and after running 35 km on an asphalt road. After the run, the dorsal height, navicular height, and arch heigh...

  7. Role of neuropathy and high foot pressures in diabetic foot ulceration.

    Science.gov (United States)

    Frykberg, R G; Lavery, L A; Pham, H; Harvey, C; Harkless, L; Veves, A

    1998-10-01

    High plantar foot pressures in association with peripheral neuropathy have been ascertained to be important risk factors for ulceration in the diabetic foot. Most studies investigating these parameters have been limited by their size and the homogeneity of study subjects. The objective of this study was therefore to ascertain the risk of ulceration associated with high foot pressures and peripheral neuropathy in a large and diverse diabetic population. We studied a cross-sectional group of 251 diabetic patients of Caucasian (group C) (n=121), black (group B) (n=36), and Hispanic (group H) (n=94) racial origins with an overall age of 58.5+/-12.5 years (range 20-83). There was an equal distribution of men and women across the entire study population. All patients underwent a complete medical history and lower extremity evaluation for neuropathy and foot pressures. Neuropathic parameters were dichotomized (0/1) into two high-risk variables: patients with a vibration perception threshold (VPT) > or =25 V were categorized as HiVPT (n=132) and those with Semmes-Weinstein monofilament tests > or =5.07 were classified as HiSWF (n=190). The mean dynamic foot pressures of three footsteps were measured using the F-scan mat system with patients walking without shoes. Maximum plantar pressures were dichotomized into a high-pressure variable (Pmax6) indicating those subjects with pressures > or =6 kg/cm2 (n=96). A total of 99 patients had a current or prior history of ulceration at baseline. Joint mobility was significantly greater in the Hispanic cohort compared with the other groups at the first metatarsal-phalangeal joint (C 67+/-23 degrees, B 69+/-23 degrees, H 82+/-23 degrees, P=0.000), while the subtalar joint mobility was reduced in the Caucasian group (C 21+/-8 degrees, B 26+/-7 degrees, H 27+/-11 degrees, P=0.000). Maximum plantar foot pressures were significantly higher in the Caucasian group (C 6.7+/-2.9 kg/cm2, B 5.7+/-2.8 kg/cm2, H 4.4+/-1.9 kg/cm2, P=0

  8. Genetics of club foot in Maori and Pacific people

    Science.gov (United States)

    Chapman, C.; Stott, N; Port, R. V.; Nicol, R.

    2000-01-01

    The role of major gene and multifactorial inheritance in the aetiology of club foot in the New Zealand Polynesian population was studied using 287 New Zealand Maori and Pacific club foot families. The club foot family data were analysed by complex segregation analysis under the mixed model using the computer program POINTER. This analysis shows that the best genetic model for club foot in this population is a single dominant gene with a penetrance of 33% and a predicted gene frequency of 0.9%. These data provide a scientific foundation for molecular studies in the Maori and Polynesian population to identify putative club foot genes.


Keywords: club foot; New Zealand Maori; complex segregation analysis PMID:10978359

  9. Mycetoma foot

    Directory of Open Access Journals (Sweden)

    Somnath Gooptu

    2013-01-01

    Full Text Available Mycetoma is an uncommon chronic granulomatous infective disease of the skin, dermis and subcutaneous tissues predominantly seen in tropical countries. A patient presented to our hospital with the swelling of the left foot with a healed sinus and a painful nodule. He gave a history of sinuses in the left foot from which there was discharge of yellow granules. Culture of the ultrasound guided fine needle aspiration cytology of the nodule revealed growths of Nocardia species. The patient was treated with a multi-drug therapy along with debridement of the painful nodule. He experienced symptomatic relief and a regression of the swelling within the three months of follow-up so far. Due to the relatively slow progression of the disease, patients are diagnosed at a late stage. Hence, emphasis should be placed on health education and the importance of wearing footwear.

  10. Welcome to Journal of Foot and Ankle Research: a new open access journal for foot health professionals

    OpenAIRE

    Borthwick Alan M; Potter Mike J; Menz Hylton B; Landorf Karl B

    2008-01-01

    Abstract Journal of Foot and Ankle Research (JFAR) is a new, open access, peer-reviewed online journal that encompasses all aspects of policy, organisation, delivery and clinical practice related to the assessment, diagnosis, prevention and management of foot and ankle disorders. JFAR will cover a wide range of clinical subject areas, including diabetology, paediatrics, sports medicine, gerontology and geriatrics, foot surgery, physical therapy, dermatology, wound management, radiology, biome...

  11. Turbulence, bubbles and drops

    NARCIS (Netherlands)

    van der Veen, Roeland

    2016-01-01

    In this thesis, several questions related to drop impact and Taylor-Couette turbulence are answered. The deformation of a drop just before impact can cause a bubble to be entrapped. For many applications, such as inkjet printing, it is crucial to control the size of this entrapped bubble. To study

  12. Treatment options for diabetic foot osteomyelitis.

    Science.gov (United States)

    Senneville, Eric; Robineau, Olivier

    2017-06-01

    Diabetic foot osteomyelitis therapeutical options are based on antibiotic therapy and surgical resection of the infected bone(s). Surgical and medical approaches of patients suffering from a diabetic foot osteomyelitis do not oppose but are complementary and need to be discussed as a tailored manner. Areas covered: The aim of the present article is to discuss data issued from the most recent guidelines of the Infectious Diseases Society of America and the International Working Group on the Diabetic Foot on the management of the diabetic foot infection and from a search in the current literature using the terms diabetic foot osteomyelitis and treatment/therapy/therapeutical in both PubMed and Medline, restricted to the last five years. Expert opinion: Surgical removal of the entire infected bone(s) has been considered in the past as the standard treatment but medical approach of these patients has now proven efficacy in selected situations. The current emergence of bacteria, especially among Gram negative rods, resistant to almost all the available antibiotics gradually augments the complexity of the management of these patients and is likely to decrease the place of the medical approach and to worsen the outcome of these infections in the next future.

  13. Intra-rater repeatability of the Oxford foot model in healthy children in different stages of the foot roll over process during gait

    DEFF Research Database (Denmark)

    Curtis, D J; Bencke, J; Stebbins, J A

    2009-01-01

    BACKGROUND: The repeatability of the Oxford foot model has been reported, but possible variations in the repeatability during the foot roll over process have not been examined. The aim of this study was to determine the relative and absolute repeatability of the model for each stage of the foot...... roll over process during gait and to compare foot kinematic data from this study with that from another centre as a preliminary examination of the model's inter-centre repeatability and validity. METHOD: Eight healthy children were tested twice at the gait laboratory. Foot kinematics from this study...... were plotted against those from an earlier repeatability study and repeatability statistics calculated for the three rockers of stance phase and swing phase. RESULTS: Foot kinematics from this study and an earlier repeatability study produced similar kinematic patterns and joint angle ranges...

  14. Fleet of Foot: Adolescent Foot and Ankle Mobility

    Science.gov (United States)

    Legacy, Kelly Bromley

    2018-01-01

    In today's world of advanced technologies, accessible transportation, and fingertip talking, adolescents are spending too many hours each day sedentary. The purpose of this article is to underscore the importance of foot and ankle mobility in an adolescent population that spends very little time on their feet. Physical educators and athletic…

  15. Hallux valgus and plantar pressure loading: the Framingham foot study

    Science.gov (United States)

    2013-01-01

    Background Hallux valgus (HV), a common structural foot deformity, can cause foot pain and lead to limited mobility. The purpose of this study was to evaluate differences in plantar pressure and force during gait by HV status in a large population-based cohort of men and women. Methods A trained examiner performed a validated physical examination on participants’ feet and recorded the presence of hallux valgus and other specific foot disorders. Each foot was classified into one of four mutually exclusive groups based on the foot examination. Foot groups were: (i) HV only, (ii) HV and at least one additional foot disorder (FD), (iii) no HV but at least one other FD, and (iv) neither HV nor FD (referent). Biomechanical data for both feet were collected using Tekscan Matscan. Foot posture during quiet standing, using modified arch index (MAI), and foot function during gait, using center of pressure excursion index (CPEI), were calculated per foot. Further, walking scans were masked into eight sub-regions using Novel Automask, and peak pressure and maximum force exerted in each region were calculated. Results There were 3205 participants, contributing 6393 feet with complete foot exam data and valid biomechanical measurements. Participants with HV had lower hallucal loading and higher forces at lesser toes as well as higher MAI and lower CPEI values compared to the referent. Participants with HV and other FDs were also noted to have aberrant rearfoot forces and pressures. Conclusions These results suggest that HV alters foot loading patterns and pressure profiles. Future work should investigate how these changes affect the risk of other foot and lower extremity ailments. PMID:24138804

  16. The reliability and validity of a three-camera foot image system for obtaining foot anthropometrics.

    Science.gov (United States)

    O'Meara, Damien; Vanwanseele, Benedicte; Hunt, Adrienne; Smith, Richard

    2010-08-01

    The purpose was to develop a foot image capture and measurement system with web cameras (the 3-FIS) to provide reliable and valid foot anthropometric measures with efficiency comparable to that of the conventional method of using a handheld anthropometer. Eleven foot measures were obtained from 10 subjects using both methods. Reliability of each method was determined over 3 consecutive days using the intraclass correlation coefficient and root mean square error (RMSE). Reliability was excellent for both the 3-FIS and the handheld anthropometer for the same 10 variables, and good for the fifth metatarsophalangeal joint height. The RMSE values over 3 days ranged from 0.9 to 2.2 mm for the handheld anthropometer, and from 0.8 to 3.6 mm for the 3-FIS. The RMSE values between the 3-FIS and the handheld anthropometer were between 2.3 and 7.4 mm. The 3-FIS required less time to collect and obtain the final variables than the handheld anthropometer. The 3-FIS provided accurate and reproducible results for each of the foot variables and in less time than the conventional approach of a handheld anthropometer.

  17. Preventing Diabetic Foot Complications : Strategic Recommendations

    African Journals Online (AJOL)

    The diabetic foot is the commonest cause of non-traumatic lower extremity amputation in the developed and developing nations. Several risk factors predispose the diabetic patient to foot ulceration and peripheral neuropathy, with peripheral vascular disease are the commonest risk factors. Clinical examination for these risk ...

  18. Gross Motor Skills in Children With Idiopathic Clubfoot and the Association Between Gross Motor Skills, Foot Involvement, Gait, and Foot Motion.

    Science.gov (United States)

    Lööf, Elin; Andriesse, Hanneke; André, Marie; Böhm, Stephanie; Iversen, Maura D; Broström, Eva W

    2017-02-24

    Little is known regarding gross motor skills (GMS) in children with idiopathic clubfoot (IC). This study describes GMS, specifically foot involvement and asymmetries, and analyses the association between GMS, gait, and foot status in children with IC. Gross motor tasks and gait were analyzed in children with IC and typically developed (TD) children. GMS were assessed using videotapes and the Clubfoot Assessment Protocol (CAP). The Gait Deviation Index (GDI) and GDI-Kinetic were calculated from gait analyses. Children were divided into bilateral, unilateral clubfoot, or TD groups. To analyze asymmetries, feet within each group were further classified into superior or inferior foot, depending on their CAP scores. Correlations identified associations between CAP and GDI, GDI-Kinetic, passive foot motion, and Dimeglio Classification Scores at birth in the clubfeet. In total, 75 children (mean age, 5 years) were enrolled (bilateral n=22, unilateral clubfoot n=25, TD=28). Children with clubfeet demonstrated significantly lower GMS, gait, and foot motion compared with TD children. One leg standing and hopping deviated in 84% and 91%, respectively, in at least one foot in children with clubfoot. Gross motor asymmetries were evident in both children with bilateral and unilateral involvement. In children with unilateral clubfoot, contralateral feet showed few deviations in GMS compared with TD; however, differences existed in gait and foot motion. The association between GMS and gait, foot motion, and initial foot status varied between poor and moderate. Gross motor deficits and asymmetries are present in children with both bilateral and unilateral IC. Development of GMS of the contralateral foot mirrors that of TD children, but modifies to the clubfoot in gait and foot motion. The weak association with gait, foot motion, and initial clubfoot severity indicates that gross motor measurements represent a different outcome entity in clubfoot treatment. We therefore, recommend

  19. Foot pain

    Science.gov (United States)

    ... that you were born with or develops later Injury Shoes that fit poorly or do not have much cushioning Too much walking or other sports activity Trauma The following can cause foot pain: Arthritis and gout . Common in the big toe, which becomes red, swollen, ...

  20. A survey of foot problems in juvenile idiopathic arthritis.

    Science.gov (United States)

    Hendry, G; Gardner-Medwin, J; Watt, G F; Woodburn, J

    2008-12-01

    Evidence suggests that foot problems are common in juvenile idiopathic arthritis (JIA), with prevalence estimates over 90%. The aim of this survey was to describe foot-related impairment and disability associated with JIA and foot-care provision in patients managed under modern treatment paradigms, including disease-modifying anti-rheumatic drugs (DMARDs) and biologic therapies. The Juvenile Arthritis Foot Disability Index (JAFI), Child Health Assessment Questionnaire (CHAQ), and pain visual analogue scale (VAS) were recorded in 30 consecutive established JIA patients attending routine outpatient clinics. Foot deformity score, active/limited joint counts, walking speed, double-support time (s) (DS) and step length symmetry index % (SI) were also measured. Foot-care provision in the preceding 12 months was determined from medical records. Sixty-three per cent of children reported some foot impairment, with a median (range) JAFI subscale score of 1 (0-3); 53% reported foot-related activity limitation, with a JAFI subscale score of 1 (0-4); and 60% reported participation restriction, with a JAFI subscale score of 1 (0-3). Other reported variables were CHAQ 0.38 (0-2), VAS pain 22 (0-79), foot deformity 6 (0-20), active joints 0 (0-7), limited joints 0 (0-31), walking speed 1.09 m/s (0.84-1.38 m/s), DS 0.22 s (0.08-0.26 s) and SI +/-4.0% (+/-0.2-+/-31.0%). A total of 23/30 medical records were reviewed and 15/23 children had received DMARDS, 8/23 biologic agents and 20/23 multiple intra-articular corticosteroid injections. Ten children received specialist podiatry care comprising footwear advice, orthotic therapy and silicone digital splints together with intrinsic muscle strengthening exercises. Despite frequent use of DMARD/biologic therapy and specialist podiatry-led foot care, foot-related impairment and disability persists in some children with JIA.

  1. Drop impact splashing and air entrapment

    KAUST Repository

    Thoraval, Marie-Jean

    2013-03-01

    Drop impact is a canonical problem in fluid mechanics, with numerous applications in industrial as well as natural phenomena. The extremely simple initial configuration of the experiment can produce a very large variety of fast and complex dynamics. Scientific progress was made in parallel with major improvements in imaging and computational technologies. Most recently, high-speed imaging video cameras have opened the exploration of new phenomena occurring at the micro-second scale, and parallel computing allowed realistic direct numerical simulations of drop impacts. We combine these tools to bring a new understanding of two fundamental aspects of drop impacts: splashing and air entrapment. The early dynamics of a drop impacting on a liquid pool at high velocity produces an ejecta sheet, emerging horizontally in the neck between the drop and the pool. We show how the interaction of this thin liquid sheet with the air, the drop or the pool, can produce micro-droplets and bubble rings. Then we detail how the breakup of the air film stretched between the drop and the pool for lower impact velocities can produce a myriad of micro-bubbles.

  2. Axisymmetric Liquid Hanging Drops

    Science.gov (United States)

    Meister, Erich C.; Latychevskaia, Tatiana Yu

    2006-01-01

    The geometry of drops hanging on a circular capillary can be determined by numerically solving a dimensionless differential equation that is independent on any material properties, which enables one to follow the change of the height, surface area, and contact angle of drops hanging on a particular capillary. The results show that the application…

  3. In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH.

    Science.gov (United States)

    Royhman, Dmitry; Patel, Megha; Jacobs, Joshua J; Wimmer, Markus A; Hallab, Nadim J; Mathew, Mathew T

    2018-02-01

    The fretting-corrosion behavior of mixed metal contacts is affected by various mechanical and electrochemical parameters. Crevice conditions at the junction and patient-specific pathologies can affect the pH of the prosthetic environment. The main objective of this study is to understand the effect of pH variation at the stem/head junction of the hip implant under fretting corrosion exposure. We hypothesized that pH will have a significant influence on the fretting-corrosion behavior hip implant modular junctions. A custom-made setup was used to evaluate the fretting corrosion behavior of hip implant modular junctions. A Newborn calf serum solution (30 g/L protein content) was used to simulate the synovial fluid environment. A sinusoidal fretting motion, with a displacement amplitude of +50 µm, was applied to the Ti alloy rod. The effects of pathology driven, periprosthetic pH variation were simulated at four different pH levels (3.0, 4.5, 6.0 and 7.6). Electrochemical and mechanical properties were evaluated before, during, and after the applied fretting motion. The impedance of the system was increased in response to the fretting motion. The hysteresis tangential load/displacement behavior was not affected by pH level. The worn surfaces of CoCrMo pins exhibited the presence of tribolayer or organic deposits, in the pH 4.5 group, which may explain the lower drop in potential and mass loss observed in that group. Mechanically dominated wear mechanisms, namely, adhesive wear was shown in the pH 7.6 group, which may account for a higher potential drop and metal content loss. This study suggests that the fretting-corrosion mechanisms in hip implant are affected by the pH levels of the surrounding environment and patient-specific factors. Copyright © 2017. Published by Elsevier Ltd.

  4. Insights from the pollination drop proteome and the ovule transcriptome of Cephalotaxus at the time of pollination drop production.

    Science.gov (United States)

    Pirone-Davies, Cary; Prior, Natalie; von Aderkas, Patrick; Smith, Derek; Hardie, Darryl; Friedman, William E; Mathews, Sarah

    2016-05-01

    Many gymnosperms produce an ovular secretion, the pollination drop, during reproduction. The drops serve as a landing site for pollen, but also contain a suite of ions and organic compounds, including proteins, that suggests diverse roles for the drop during pollination. Proteins in the drops of species of Chamaecyparis, Juniperus, Taxus, Pseudotsuga, Ephedra and Welwitschia are thought to function in the conversion of sugars, defence against pathogens, and pollen growth and development. To better understand gymnosperm pollination biology, the pollination drop proteomes of pollination drops from two species of Cephalotaxus have been characterized and an ovular transcriptome for C. sinensis has been assembled. Mass spectrometry was used to identify proteins in the pollination drops of Cephalotaxus sinensis and C. koreana RNA-sequencing (RNA-Seq) was employed to assemble a transcriptome and identify transcripts present in the ovules of C. sinensis at the time of pollination drop production. About 30 proteins were detected in the pollination drops of both species. Many of these have been detected in the drops of other gymnosperms and probably function in defence, polysaccharide metabolism and pollen tube growth. Other proteins appear to be unique to Cephalotaxus, and their putative functions include starch and callose degradation, among others. Together, the proteins appear either to have been secreted into the drop or to occur there due to breakdown of ovular cells during drop production. Ovular transcripts represent a wide range of gene ontology categories, and some may be involved in drop formation, ovule development and pollen-ovule interactions. The proteome of Cephalotaxus pollination drops shares a number of components with those of other conifers and gnetophytes, including proteins for defence such as chitinases and for carbohydrate modification such as β-galactosidase. Proteins likely to be of intracellular origin, however, form a larger component of drops

  5. Iambic Feet in Paumari and the Theory of Foot Structure

    Directory of Open Access Journals (Sweden)

    Daniel L. Everett

    2003-01-01

    Full Text Available This paper analyzes stress and moraic constituencies in Paumari, an endangered language of the Arawan family of the Brazilian Amazon. It argues that Paumari feet are quantity-insensitive iambs, built from right-to-left within the prosodic word. Both of these latter claims are theoretically important because they violate some proposed universals of foot structure. The paper also discusses more general implications of the Paumari data for theories of foot size and shape, proposing two constraints on foot size, Foot Maximality and Foot Minimality, to replace the less fine-tuned constraint Foot Binarity.

  6. The prevalence of diabetic foot disease in the Waikato region.

    Science.gov (United States)

    O'Shea, C; McClintock, J; Lawrenson, R

    2017-07-01

    The aim of this study was to establish the prevalence of diabetic foot disease by utilising the retinal eye screening register in the Waikato region of New Zealand. Understanding both the prevalence and the degree of foot disease across the general diabetes population will help to determine what podiatry services are required for people with diabetes. 2192 people aged 15years and over, who attended the Waikato Regional Diabetes Service mobile retinal photo screening service for the six-month period between May and November 2014, consented to a foot screen including testing for sensation and pedal pulses. A digital image was taken of the dorsal and plantar aspect of each foot for review by a registered Podiatrist. Thirteen percent of the study sample was identified as having a high-risk foot including active foot complications. 65% were categorised as low risk and a further 22% at moderate risk of diabetic foot disease. Factors identified as significant included age, type of diabetes, duration of diabetes, and smoking. These factors placed people at greater risk of diabetic foot disease. A significant number of people with diabetes are at risk of diabetic foot disease. This study has highlighted the need for targeted podiatry services to address diabetic foot disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Hand, Foot, and Mouth Disease

    Centers for Disease Control (CDC) Podcasts

    2013-08-08

    Hand, foot, and mouth disease is a contagious illness that mainly affects children under five. In this podcast, Dr. Eileen Schneider talks about the symptoms of hand, foot, and mouth disease, how it spreads, and ways to help protect yourself and your children from getting infected with the virus.  Created: 8/8/2013 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 8/8/2013.

  8. A study of dynamic foot pressure measurement in diabetic patients

    Directory of Open Access Journals (Sweden)

    Milka D Madhale

    2017-01-01

    Full Text Available Introduction: Diabetic foot ulcer is a major source of morbidity and a leading cause of hospitalization. It is estimated that approximately 20% of hospital admissions among patients with diabetes mellitus are due to diabetic foot ulcer. It can lead to infection, gangrene, amputation, and even death if appropriate care is not provided. Overall, the lower limb amputation in diabetic patients is 15 times higher than in non-diabetics. In the majority of cases, the cause for the foot ulcer is the altered architecture of the foot due to neuropathy resulting in abnormal pressure points on the soles. Purpose: The aim of this study is to develop low cost, lightweight foot pressure scanner and check its reliability and validity which can help to prevent foot ulceration. Design/Methodology/Approach: In the present study, a low cost, lightweight foot pressure scanner is developed, and dynamic plantar pressures in a group of 110 Indian patients with diabetes with or without neuropathy and foot ulcers are measured. Practical Implications: If these pressure points can be detected, ulcers can be prevented by providing offloading footwear. Originality/Value: Differences are found in dynamic foot pressures in different study groups, namely, diabetic patients, patients with diabetic peripheral neuropathy, patients with foot ulcers, and nondiabetics. The differences are significant (P < 0.01, which showed the validity of the tool. Reliability and consistency of the tool was checked by test–retest method. Paper Type: Original Research work. Conclusion: Based on the results of the present study, it is concluded that the scanner is successfully developed and it can measure foot pressures. It is a novel device to proactively monitor foot health in diabetics in an effort to prevent and reduce diabetic foot complications.

  9. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  10. Clinical and functional correlates of foot pain in diabetic patients.

    NARCIS (Netherlands)

    Rijken, P.M.; Dekker, J.; Rauwerda, J.A.; Dekker, E.; Lankhorst, G.J.; Bakker, K.; Dooren, J.

    1998-01-01

    Purpose: patients with diabetes mellitus frequently suffer from foot pain. This pain seems to be a neglected area in studies on the diabetic foot. The purpose of this study was to identify clinical variables associated with foot pain in diabetic patients. In addition, the relationships between foot

  11. The Effect of Foot Exercises on Wound Healing in Type 2 Diabetic Patients With a Foot Ulcer.

    Science.gov (United States)

    Eraydin, Şahizer; Avşar, Gülçin

    2017-12-19

    The purpose of this study was to investigate the effect of foot exercises on wound healing in type 2 diabetic patients with a diabetic foot ulcer. Prospective, randomized controlled study. Sixty-five patients from an outpatient clinic with grade 1 or 2 ulcers (Wagner classification) who met study criteria agreed to participate; 60 patients completed the study and were included in the final analysis. Subjects were followed up between February 2014 and June 2015. Subjects were recruited by the researchers in the clinics where they received treatment. Subjects were randomly allocated to either the control or intervention group. Data were collected using investigator-developed forms: patient information form and the diabetic foot exercises log. Patients in the intervention group received standard wound care and performed daily foot exercises for 12 weeks; the control group received standard wound care but no exercises. The ulcers of the patients in both the intervention and control groups were examined and measured at the 4th, 8th, and 12th weeks. The groups were compared in terms of the ulcer size and depth. To analyze and compare the data, frequency distribution, mean (standard deviation), variance analysis, and the independent samples t test and the χ test were used. The mean ulcer areas were 12.63 (14.43), 6.91 (5.44), 4.30 (3.70), and 3.29 (3.80) cm (P diabetic foot ulcer sizes in the study intervention group in the 4th and 12th weeks compared to beginning baseline (P ≤ .05). However, only the 12th week was different from the beginning in the control group (P = .000). The mean depths of the ulcers were 0.56 (0.85), 0.42 (0.68), 0.36 (0.50), and 0.28 (0.38) cm in the study intervention group (P foot exercises should be included in the treatment plan when managing patients with diabetic foot ulcers.

  12. CANFLEX fuel bundle junction pressure drop

    International Nuclear Information System (INIS)

    Chung, H. J.; Chung, C. H.; Jun, J. S.; Hong, S. D.; Chang, S. K.; Kim, B. D.

    1996-11-01

    This report describes the junction pressure drop test results which are to used to determine the alignment angle between bundles to achieve the most probable fuel string pressure drop for randomly aligned bundles for use in the fuel string total pressure drop test. (author). 4 tabs., 17 figs

  13. CANFLEX fuel bundle junction pressure drop

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. J.; Chung, C. H.; Jun, J. S.; Hong, S. D.; Chang, S. K.; Kim, B. D.

    1996-11-01

    This report describes the junction pressure drop test results which are to used to determine the alignment angle between bundles to achieve the most probable fuel string pressure drop for randomly aligned bundles for use in the fuel string total pressure drop test. (author). 4 tabs., 17 figs.

  14. 49 CFR 178.603 - Drop test.

    Science.gov (United States)

    2010-10-01

    ... used for the hydrostatic pressure or stacking test. Exceptions for the number of steel and aluminum..., non-resilient, flat and horizontal surface. (e) Drop height. Drop heights, measured as the vertical... than flat drops, the center of gravity of the test packaging must be vertically over the point of...

  15. Foot length is a functional parameter for assessment of height.

    Science.gov (United States)

    Krishan, Kewal; Kanchan, Tanuj

    2013-03-01

    Stature estimation is considered as an important parameter in the examination of unknown human remains and during the analysis of evidence in crime scene investigations. During mass disasters isolated foot can be found enclosed in the shoes while footprints may be recovered at the crime scenes. Foot length and footprint length can provide valuable estimates of stature. The present communication makes a few pertinent observations on a recently published article in 'The Foot' entitled 'Foot length-a functional parameter for assessment of height, The Foot 2012, 22(1):31-34' and presents an insight into the literature available on the subject which is likely to be of value to future researchers in the field of Forensic Podiatry. The foot length and the footprint length of individuals differ from each other and hence, the research observations made in a study on foot prints cannot be applied to foot dimensions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Effect of ski mountaineering track on foot sole loading pattern.

    Science.gov (United States)

    Haselbacher, Matthias; Mader, Katharina; Werner, Maximiliane; Nogler, Michael

    2014-09-01

    Ski mountaineering is becoming a popular sport. The ascending techniques (tracks) can be divided into 3 different groups: flat field, direct ascent, and traversing. This study examines the relationship between different mechanical loads on the foot and the 4 different mountaineering ascending techniques. All subjects used the same pair of ski boots and the same skis while performing the 4 different ascending techniques. An in-shoe dynamic pressure measuring system was used to measure the mechanical load on the foot soles of each ski mountaineer. The foot sole was divided into 6 anatomic sections to measure the different loads in each section. Thirteen men with an average age of 29 years were enrolled in the study. The results showed small, not significant differences in the mechanical foot load in the flat field or in the direct ascent. The average mechanical foot load was highest on the valley side foot while traversing (179 kPa to 117 kPa). The higher load forces were in the medial ball of the foot and the longitudinal aspect of the foot side closer to the hill. The higher impact placed on the valley side foot and the concentration of force placed on the medial ball of the valley side foot suggested the influence of the track on the load pattern of the foot sole. This higher impact may result in upward forces that affect the force distribution in the ankle and knee joints. Copyright © 2014. Published by Elsevier Inc.

  17. Painful Lytic Lesions of the Foot : A Case Report

    Directory of Open Access Journals (Sweden)

    R Vaishya

    2015-03-01

    Full Text Available The presence of lytic lesions in the bones of foot raises a number of diagnostic possibilities ranging from infection, inflammatory pathology to neoplastic conditions. Although the radiological picture is not pathognomonic of any pathology, clinical history and histopathological examination can help to clinch the diagnosis. We present a case of multiple lytic lesions of the foot and discuss possible differential diagnoses. The patient was diagnosed as a case of madura foot and the lesions responded to surgical debridement and anti-fungal treatment with a good functional outcome. Madura foot is an uncommon, chronic granulomatous fungal or bacterial infection with a predilection in people who walk barefoot. Although known for a specific geographical distribution, madura foot should be kept as a possible diagnosis in patients presenting with lytic lesions of the foot due to population emigration across the world.

  18. Diabetes: foot ulcers and amputations.

    Science.gov (United States)

    Hunt, Dereck L

    2011-08-26

    Diabetic foot ulceration is full-thickness penetration of the dermis of the foot in a person with diabetes. Severity is classified using the Wagner system, which grades it from 1 to 5. The annual incidence of ulcers among people with diabetes is 2.5% to 10.7% in resource-rich countries, and the annual incidence of amputation for any reason is 0.25% to 1.8%. We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of interventions to prevent foot ulcers and amputations in people with diabetes? What are the effects of treatments in people with diabetes with foot ulceration? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2010 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). We found 50 systematic reviews and RCTs that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. In this systematic review, we present information relating to the effectiveness and safety of the following interventions: debridement, human cultured dermis, human skin equivalent, patient education, pressure off-loading with felted foam or pressure-relief half-shoe, pressure off-loading with total-contact or non-removable casts, screening and referral to foot-care clinics, systemic hyperbaric oxygen for non-infected ulcers, systemic hyperbaric oxygen in infected ulcers, therapeutic footwear, topical growth factors, and wound dressings.

  19. Reliability, validity and responsiveness of the Spanish Manchester-Oxford Foot Questionnaire (MOXFQ) in patients with foot or ankle surgery.

    Science.gov (United States)

    Garcés, Juan B Gerstner; Winson, Ian; Goldhahn, Sabine; Castro, Michael D; Swords, Michael P; Grujic, Leslie; Rammelt, Stefan; Sands, Andrew K

    2016-03-01

    The Manchester-Oxford Foot Questionnaire (MOXFQ) has been validated in Spanish for use in patients undergoing foot and ankle surgery. 120 patients completed the MOXFQ and the SF-36 before surgery and 6 and 12 months postoperative. Surgeons completed the American Orthopaedic Foot and Ankle Society (AOFAS) Clinical Rating System. Psychometric properties were assessed for all three MOXFQ dimensions, and for the MOXFQ Index. The Spanish MOXFQ demonstrated consistency with Cronbach's alpha values between 0.65 and 0.90, and reliability ([ICCs] >0.95). It shows a moderate to strong correlation between the Walking/standing dimension and the related domains of the SF-36 (|r|>0.6), the AOFAS Ankle-Hindfoot Scale (|r|>0.47) and Hallux-MTP-IP Scale (|r|>0.64). Responsiveness was excellent, (effect sizes >2.1). The respective minimal detectable change (MDC90) was 14.18 for the MOXFQ Index. The Spanish version of the MOXFQ showed good psychometric properties in patients with foot and ankle disorders. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  20. The effects of N+ implantation on the wear and friction of type 304 and 15-5 PH stainless steels

    International Nuclear Information System (INIS)

    Yost, F.G.; Picraux, S.T.; Follstaedt, D.M.; Pope, L.E.; Knapp, J.A.

    1983-01-01

    Ion implantation of N + into mechanically polished type 304 and 15-5 PH stainless steels was studied to determine its effect on dry wear and friction behavior. Implantation of 4.0 X 10 17 N + cm -2 at 50 keV yielded a depth profile with a peak concentration of about 45 at.% at a depth of 70 nm which dropped to about 10 at.% at 120 nm. Wear and friction were studied in an unlubricated pin-on-disc configuration using type 304 and 440C stainless steel pins. Both N + -implanted steels exhibited reduced wear at low loads but no significant reduction in the coefficient of friction was found. At the lowest normal load studied (12.3 gf), the average maximum wear depth of the implanted 15-5 PH stainless steel disc (about 0.1 μm) was reduced to approximately 10% of that for the corresponding unimplanted pin-on-disc pair after 1000 cycles. At normal loads of 50 gf or above (corresponding to hertzian stresses of 1160 MPa or higher) all beneficial effects were gone. Vacuum heat treatment at 923 K for 1.8 ks of an identically implanted type 304 stainless steel specimen eradicated the beneficial effects of the nitrogen implantation. The N + -implanted discs show similar reductions in wear to discs implanted with titanium and carbon, but the N + -implanted discs do not exhibit the reductions in the coefficient of friction seen with the discs implanted with titanium and carbon. (Auth.)

  1. Liquid-gas mass transfer at drop structures

    DEFF Research Database (Denmark)

    Matias, Natércia; Nielsen, Asbjørn Haaning; Vollertsen, Jes

    2017-01-01

    -water mass transfer, little is known about hydrogen sulfide emission under highly turbulent conditions (e.g., drop structures, hydraulic jumps). In this study, experimental work was carried out to analyze the influence of characteristics of drops on reaeration. Physical models were built, mimicking typical...... sewer drop structures and allowing different types of drops, drop heights, tailwater depths and flow rates. In total, 125 tests were performed. Based on their results, empirical expressions translating the relationship between the mass transfer of oxygen and physical parameters of drop structures were...... established. Then, by applying the two-film theory with two-reference substances, the relation to hydrogen sulfide release was defined. The experiments confirmed that the choice of the type of drop structure is critical to determine the uptake/emission rates. By quantifying the air-water mass transfer rates...

  2. Preventative foot care in people with diabetes: Quality patient ...

    African Journals Online (AJOL)

    Keywords: preventative foot care; diabetes; risk stratification: self care. Introduction ... diabetes is considered to be a key indicator of the quality of foot ... loss of protective sensation, the importance of foot monitoring on a daily basis, the proper ...

  3. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  4. Nonlinear oscillations of inviscid free drops

    Science.gov (United States)

    Patzek, T. W.; Benner, R. E., Jr.; Basaran, O. A.; Scriven, L. E.

    1991-01-01

    The present analysis of free liquid drops' inviscid oscillations proceeds through solution of Bernoulli's equation to obtain the free surface shape and of Laplace's equation for the velocity potential field. Results thus obtained encompass drop-shape sequences, pressure distributions, particle paths, and the temporal evolution of kinetic and surface energies; accuracy is verified by the near-constant drop volume and total energy, as well as the diminutiveness of mass and momentum fluxes across drop surfaces. Further insight into the nature of oscillations is provided by Fourier power spectrum analyses of mode interactions and frequency shifts.

  5. Reconstruction of soft tissue defects around the ankle and foot

    Directory of Open Access Journals (Sweden)

    Bharat Bhushan Dogra

    2014-01-01

    Full Text Available Introduction: Soft tissue defects over ankle and foot region are encountered quite frequently following road traffic trauma and surgery. Management of such cases is a challenging task for any reconstructive surgeon because of paucity of skin and relative poor vascular status of skin in this region. Hence, invariably such cases require microsurgical free flap coverage, expertise for which may not be available at all the centers, such procedures require long operating hours and suitable recipient vessel may not be available in crush injuries. Materials and Methods: Thirty consecutive patients having soft tissue defects around ankle and foot region who underwent various reconstructive procedures in a medical college hospital during last 2 years form the basis of this study. This study was carried out to enlist various etiological factors and reconstructive surgical procedures employed to manage such cases without microsurgery. Results: The age of these patients ranged from 9 to 72 years. Twenty-five patients were males while 05 were females, with a mean age of 25 years. Road traffic accidents happened to be the primary cause of such defects in as many as 15 patients, cycle spoke trauma in 02 patients, implant exposure following orthopedic surgery in 6 patients, diabetic angiopathy in 4 patients and chronic osteomyelitis in 3 patients. The site of the defect was lower fourth of tibia in 16 patients, dorsum of foot in 2 patients, sole in 5 patients, medial aspect of ankle in 02 cases, lateral aspect in 02 cases and retro calcaneal region in 03 cases. In 10 cases distally based superficial sural artery flap was used to reconstruct the defect. In step rotation flap was used to provide sensory flap cover in the weight bearing heel in 04 cases. Inferiorly based fasciocutanenous flaps in 09 cases and muscle flaps were used in 07 cases. Conclusion: Distally based sural artery based flaps are very handy to provide skin cover around ankle and malleolar

  6. Maxillary Four Implant-retained Overdentures via Locator® Attachment: Intermediate-term Results from a Retrospective Study.

    Science.gov (United States)

    Wang, Feng; Monje, Alberto; Huang, Wei; Zhang, Zhiyong; Wang, Guomin; Wu, Yiqun

    2016-06-01

    Maxillary overdentures have been utilized to restore oral function in scenarios where limited bone structure represents a drawback for financial issues and for cases where oral hygiene is uncertain. The aim of this study was to evaluate the intermediate-term clinical outcome of four locator attachment retaining maxillary overdentures and to test their reliability. A retrospective study was conducted from January 2007 to October 2013. After the placement of four maxillary dental implants and a healing period of approximately 3 months, all the implants were restored with locator-retained overdentures with partial palatal coverage. Subjects and implant characteristics, implant position (anterior vs posterior maxilla), bone quality, and opposing dentition were recorded. Peri-implant clinical parameters and marginal bone loss (MBL) were evaluated after delivery of the final prosthesis and annually thereafter. The performance of locator components and the prosthetic restoration were also recorded at follow-up. A total of 104 implants were placed in 26 subjects (11 women, 15 men; mean age, 64 years; age range, 55-76 years). One implant failed before loading. One subject dropped out of the study during a mean follow-up period of 46 months (range: 7-73 months), achieving an overall survival rate of 95.2%. Clinical parameters revealed healthy tissues around most of the implants, with low scores of plaque and bleeding indices. At the last follow-up evaluation, the mean MBL was 1.7 ± 1.1 mm (0.4-2.6 mm). Regression model analysis indicated that MBL for implants in the posterior maxilla was significantly higher than that for implants in the anterior maxilla (p = .0487). Overall, 26 technical and prosthetic complications were reported. Within the limitations of this study, maxillary four implant-retained overdentures via Locator attachment seem to be a predictable alternative for oral rehabilitation. © 2015 Wiley Periodicals, Inc.

  7. Age determination enhanced by embryonic foot bud and foot plate measurements in relation to Carnegie stages, and the influence of maternal cigarette smoking

    DEFF Research Database (Denmark)

    Lutterodt, M C; Rosendahl, M; Yding Andersen, C

    2009-01-01

    habits, and delivered a urine sample for cotinine analysis. Embryonic age was evaluated by vaginal ultrasound measurements and by post-termination foot length and compared with the Carnegie stages. RESULTS: Foot bud and foot plate were defined and measured as foot length in embryos aged 35-47 days p.......c. (range 0.8-2.1 mm). In embryos and fetuses aged 41-69 days p.c., heel-toe length was measured (range 2.5-7.5 mm). We found a significant linear correlation between foot length and age. Morphology of the feet was compared visually with the Carnegie collection, and we found that the mean ages of the two...

  8. The forgotten foot - an assessment of foot and ankle radiograph pathology in final year medical students.

    LENUS (Irish Health Repository)

    Groarke, P J

    2014-04-27

    It has been shown that doctors in Emergency Departments (EDs) have inconsistent knowledge of musculoskeletal anatomy. This is most likely due to a deficiency in focused musculoskeletal modules at undergraduate level in medical school. The aims of this study were to evaluate the knowledge of final year medical students on foot anatomy and common foot and ankle pathology as seen on radiographs.

  9. Footwear interventions for foot pain, function, impairment and disability for people with foot and ankle arthritis: A literature review.

    Science.gov (United States)

    Frecklington, Mike; Dalbeth, Nicola; McNair, Peter; Gow, Peter; Williams, Anita; Carroll, Matthew; Rome, Keith

    2017-11-03

    To conduct a literature review on the effectiveness of footwear on foot pain, function, impairment and disability for people with foot and ankle arthritis. A search of the electronic databases Scopus, Medline, CINAHL, SportDiscus and the Cochrane Library was undertaken in September 2017. The key inclusion criteria were studies reporting on findings of footwear interventions for people with arthritis with foot pain, function, impairment and/or disability. The Quality Index Tool was used to assess the methodological quality of studies included in the qualitative synthesis. The methodological variation of the included studies was assessed to determine the suitability of meta-analysis and the grading of recommendations, assessment, development and evaluation (GRADE) system. Between and within group effect sizes were calculated using Cohen's d. 1440 studies were identified for screening with 11 studies included in the review. Mean (range) quality scores were 67% (39-96%). The majority of studies investigated rheumatoid arthritis (n = 7), but also included gout (n = 2), and 1st metatarsophalangeal joint osteoarthritis (n = 2). Meta-analysis and GRADE assessment were not deemed appropriated based on methodological variation. Footwear interventions included off-the-shelf footwear, therapeutic footwear and therapeutic footwear with foot orthoses. Key footwear characteristics included cushioning and a wide toe box for rheumatoid arthritis; cushioning, midsole stability and a rocker-sole for gout; and a rocker-sole for 1st metatarsophalangeal joint osteoarthritis. Between group effect sizes for outcomes ranged from 0.01 to 1.26. Footwear interventions were associated with reductions in foot pain, impairment and disability for people with rheumatoid arthritis. Between group differences were more likely to be observed in studies with shorter follow-up periods in people with rheumatoid arthritis (12 weeks). Footwear interventions improved foot pain, function and disability in

  10. Care of Patients with Diabetic Foot Disease in Oman

    Science.gov (United States)

    Al-Busaidi, Ibrahim S.; Abdulhadi, Nadia N.; Coppell, Kirsten J.

    2016-01-01

    Diabetes mellitus is a major public health challenge and causes substantial morbidity and mortality worldwide. Diabetic foot disease is one of the most debilitating and costly complications of diabetes. While simple preventative foot care measures can reduce the risk of lower limb ulcerations and subsequent amputations by up to 85%, they are not always implemented. In Oman, foot care for patients with diabetes is mainly provided in primary and secondary care settings. Among all lower limb amputations performed in public hospitals in Oman between 2002–2013, 47.3% were performed on patients with diabetes. The quality of foot care among patients with diabetes in Oman has not been evaluated and unidentified gaps in care may exist. This article highlights challenges in the provision of adequate foot care to Omani patients with diabetes. It concludes with suggested strategies for an integrated national diabetic foot care programme in Oman. PMID:27606104

  11. The Drop Tower Bremen -Experiment Operation

    Science.gov (United States)

    Könemann, Thorben; von Kampen, Peter; Rath, Hans J.

    The idea behind the drop tower facility of the Center of Applied Space Technology and Micro-gravity (ZARM) in Bremen is to provide an inimitable technical opportunity of a daily access to short-term weightlessness on earth. In this way ZARM`s european unique ground-based microgravity laboratory displays an excellent economic alternative for research in space-related conditions at low costs comparable to orbital platforms. Many national and international ex-perimentalists motivated by these prospects decide to benefit from the high-quality and easy accessible microgravity environment only provided by the Drop Tower Bremen. Corresponding experiments in reduced gravity could open new perspectives of investigation methods and give scientists an impressive potential for a future technology and multidisciplinary applications on different research fields like Fundamental Physics, Astrophysics, Fluid Dynamics, Combus-tion, Material Science, Chemistry and Biology. Generally, realizing microgravity experiments at ZARM`s drop tower facility meet new requirements of the experimental hardware and may lead to some technical constraints in the setups. In any case the ZARM Drop Tower Operation and Service Company (ZARM FAB mbH) maintaining the drop tower facility is prepared to as-sist experimentalists by offering own air-conditioned laboratories, clean rooms, workshops and consulting engineers, as well as scientific personal. Furthermore, ZARM`s on-site apartment can be used for accommodations during the experiment campaigns. In terms of approaching drop tower experimenting, consulting of experimentalists is mandatory to successfully accomplish the pursued drop or catapult capsule experiment. For this purpose there will be a lot of expertise and help given by ZARM FAB mbH in strong cooperation to-gether with the experimentalists. However, in comparison to standard laboratory setups the drop or catapult capsule setup seems to be completely different at first view. While defining a

  12. Movement coordination patterns between the foot joints during walking

    Directory of Open Access Journals (Sweden)

    John B. Arnold

    2017-10-01

    Full Text Available Abstract Background In 3D gait analysis, kinematics of the foot joints are usually reported via isolated time histories of joint rotations and no information is provided on the relationship between rotations at different joints. The aim of this study was to identify movement coordination patterns in the foot during walking by expanding an existing vector coding technique according to an established multi-segment foot and ankle model. A graphical representation is also described to summarise the coordination patterns of joint rotations across multiple patients. Methods Three-dimensional multi-segment foot kinematics were recorded in 13 adults during walking. A modified vector coding technique was used to identify coordination patterns between foot joints involving calcaneus, midfoot, metatarsus and hallux segments. According to the type and direction of joints rotations, these were classified as in-phase (same direction, anti-phase (opposite directions, proximal or distal joint dominant. Results In early stance, 51 to 75% of walking trials showed proximal-phase coordination between foot joints comprising the calcaneus, midfoot and metatarsus. In-phase coordination was more prominent in late stance, reflecting synergy in the simultaneous inversion occurring at multiple foot joints. Conversely, a distal-phase coordination pattern was identified for sagittal plane motion of the ankle relative to the midtarsal joint, highlighting the critical role of arch shortening to locomotor function in push-off. Conclusions This study has identified coordination patterns between movement of the calcaneus, midfoot, metatarsus and hallux by expanding an existing vector cording technique for assessing and classifying coordination patterns of foot joints rotations during walking. This approach provides a different perspective in the analysis of multi-segment foot kinematics, and may be used for the objective quantification of the alterations in foot joint

  13. Metallic Foreign Body in the Foot

    Directory of Open Access Journals (Sweden)

    Firat Ozan

    2016-04-01

    Full Text Available Aim: A foreign body injury of the foot is a frequently encountered problem. These foreign bodies can lead to various complications in the affected tissues, and their removal can be difficult and time consuming. Therefore, the removal of a foreign body requires good preoperative preparations. The surgical treatment results of patients with a foreign body, identified as a sewing needle, that had penetrated their foot were evaluated. Material and Method: Thirty-four patients (11 males, 23 females; mean age, 30.2 ± 18.6 years who were surgically treated between 2011 and 2013 were included. Data concerning the affected limb, placement of the needle, imaging techniques, season when the injury occurred, time between medical intervention and injury, anaesthesia type, fluoroscopy of use during surgery and surgical complications were analyzed. Results: A sewing needle had penetrated the right foot of 20 (58.8% patients and the left foot of 14 (41.1% patients. Broken needles were found in the toes of 14 (41.1% patients, in the middle of the foot of 12 (35.2% patients and in the heel area of 8 (23.5% patients. The injuries occurred in summer in 13 (38.2% patients, in winter in seven (20.6% patients, in spring in one (2.9% patient and in autumn in 13 (38.2% patients. Needle penetration had occurred in 28 (82.3% patients at home and 6 (17.6% patients outside of the home environment. The average follow-up time was 8.9 ± 2.8 months. Discussion: Removal of foreign bodies from the foot requires good preoperative preparations. Foreign bodies can lead to various complications in the affected tissues. It is important to perform detailed physical and radiological examinations to obtain good treatment results in these patients.

  14. Ultrasound Findings of the Painful Ankle and Foot

    Directory of Open Access Journals (Sweden)

    Suheil Artul

    2014-01-01

    Full Text Available Objectives: To document the prevalence and spectrum of musculoskeletal ultrasound (MSKUS findings at different parts of the foot. Materials and Methods: All MSKUS studies conducted on the foot during a 2-year period (2012-2013 at the Department of Radiology were reviewed. Demographic parameters including age, gender, and MSKUS findings were documented. Results: Three hundred and sixty-four studies had been conducted in the 2-year period. Ninety-three MSKUS evaluations were done for the ankle, 30 studies for the heel, and 241 for the rest of the foot. The most common MSKUS finding at the ankle was tenosynovitis, mostly in female patients; at the heel it was Achilles tendonitis, also mostly in female patients; and for the rest of the foot it was fluid collection and presence of foreign body, mainly in male patients. The number of different MSKUS abnormalities that were reported was 9 at the ankle, 9 at the heel, and 21 on the rest of the foot. Conclusions: MSKUS has the potential for revealing a huge spectrum of abnormalities. The most common finding was collection/hematoma and foreign bodies at the foot, tenosynovitis at the ankle, and Achilles tendinitis at the heel.

  15. 29 CFR 1918.104 - Foot protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Foot protection. 1918.104 Section 1918.104 Labor... following consensus standards: (i) ASTM F-2412-2005, “Standard Test Methods for Foot Protection,” and ASTM F... footwear that is constructed in accordance with one of the above consensus standards will be deemed to be...

  16. Factors associated with combined hand and foot eczema

    DEFF Research Database (Denmark)

    Agner, T; Aalto-Korte, K; Andersen, K E

    2017-01-01

    BACKGROUND: As for hand eczema, the aetiology of foot eczema is multifactorial and not very well understood. The aim of the present study was to identify factors associated with foot eczema in a cohort of hand eczema patients being classified into different subgroups. METHODS: Associations between...... foot and hand eczema were studied in a cross-sectional design in a cohort of hand eczema patients. Consecutive patients were recruited from nine different European Centres during the period October 2011-September 2012. Data on demographic factors, presence of foot eczema, hand eczema duration...... and severity, and whether the hand eczema was work-related or not were available, as well as patch-test results. RESULTS: Of a total of 427 hand eczema patients identified, information on foot eczema was available in 419 patients who were included in the present study. A total of 125 patients (29.8%) had...

  17. Foot posture in basketball players with history of the shin splint

    Directory of Open Access Journals (Sweden)

    Saeed Forghany

    2013-07-01

    Full Text Available Introduction: Shin splint is one of the common injuries in most athletes. Although the relationship between abnormal foot posture and shin splint has been reported previously but, the relation between foot posture and shin splint has not been well documented. The aim of this study was to explore the relationship between foot postures in basketball players and the history of shin splint. Materials and Methods: Thirty Iranian male basketball players who had experience of shin splint during last three months were participated in this study. Foot Posture Index (FPI-6 was used as the measure of foot posture. Talar head palpation, curvature at the lateral malleoli, inversion/eversion of the calcaneus, prominence in the region of the talonavicular joint, congruence of the medial longitudinal arch, abduction /adduction of the forefoot on the rear foot were 6 items which were assessed with FPI in the standing position. Foot posture was defined as ‘normal’, ‘supinated’ or ‘pronated. Data were collected and analyzed by SPSS, version16. Results: Most participants showed abnormal foot posture (%80. Fifty-three percent of subjects had pronated foot (%53 and 10% did hyper-pronation. The foot postures of 17% of participants were in supination. The results of this study did not show a significant difference in foot posture between right and left foot (P > 0.05. Conclusion: abnormal foot posture were common (%80 in basketball players with the history of shin splints. These findings could support this idea that the footwear and orthotic prescription both can prevent and treat basketball players with history of shin splints. Keywords: Foot posture, Shin splints, Basketball

  18. Immediate versus early non-occlusal loading of dental implants placed flapless in partially edentulous patients. One-year results from a randomised controlled trial.

    Science.gov (United States)

    Merli, Mauro; Merli, Aldo; Bernardelli, Francesco; Lombardini, Francesco; Esposito, Marco

    2008-01-01

    To compare immediate versus early (6 weeks) non-occlusal loading of dental implants placed flapless in partially edentulous patients 1 year after loading. Sixty patients were randomised: 30 to the immediately loaded group and 30 to the early loaded group. In order to be immediately loaded, implants were inserted with a minimum torque of > or = 40Ncm. Implants were fully occlusally loaded after 6 months. Outcome measures were prosthesis and implant failures, and biological and biomechanical complications. Five implants in five patients randomised to the immediately loaded group did not reach the required primary implant stability. Three of these implants (two prostheses) were not immediately loaded. Two patients who were randomised to the early loaded group were immediately loaded erroneously. Implants in five patients of the early loaded group were conventionally loaded. No patient dropped out and there were no failures. Two complications occurred in the early and one in the immediately loaded group (no statistically significant difference), but were solved. The use of a flapless technique for placing dental implants in conjunction with non-occlusal immediate or early loading in selected patients can provide excellent clinical results. No differences were observed when comparing implants that were loaded immediately or early. Therefore, when a high primary implant stability is obtained, it might be preferable to load the implants immediately rather than waiting for a few weeks.

  19. Pendent_Drop: An ImageJ Plugin to Measure the Surface Tension from an Image of a Pendent Drop

    Directory of Open Access Journals (Sweden)

    Adrian Daerr

    2016-01-01

    Full Text Available The pendent drop method for surface tension measurement consists in analysing the shape of an axisymmetric drop hanging from a capillary tube. This software is an add-on for the public domain image processing software ImageJ which matches a theoretical profile to the contour of a pendent drop, either interactively or by automatically minimising the mismatch. It provides an estimate of the surface tension, drop volume and surface area from the best matching parameters. It can be used in a headless setup. It is hosted on http://fiji.sc/List_of_update_sites with the source code on https://github.com/adaerr/pendent-drop

  20. Scriptaid and 5-aza-2'deoxycytidine enhanced expression of pluripotent genes and in vitro developmental competence in interspecies Black-footed cat cloned embryos

    Science.gov (United States)

    Gómez, M. C.; Biancardi, M.N.; Jenkins, J.A.; Dumas, C.; Galiguis, J.; Wang, G.; Earle Pope, C.

    2012-01-01

    Somatic cell nuclear transfer offers the possibility of preserving endangered species including the black-footed cat, which is threatened with extinction. The effectiveness and efficiency of somatic cell nuclear transfer (SCNT) depends on a variety of factors, but 'inappropriate epigenetic reprogramming of the transplanted nucleus is the primary cause of the developmental failure of cloned embryos. Abnormal epigenetic events such as DNA methylation and histone modifications during SCNT perturb the expression of imprinted and pluripotent-related genes that, consequently, may result in foetal and neonatal abnormalities. We have demonstrated that pregnancies can be established after transfer of black-footed cat cloned embryos into domestic cat recipients, but none of the implanted embryos developed to term and the foetal failure has been associated to aberrant reprogramming in cloned embryos. There is growing evidence that modifying the epigenetic pattern of the chromatin template of both donor cells and reconstructed embryos with a combination of inhibitors of histone deacetylases and DNA methyltransferases results in enhanced gene reactivation and improved in vitro and in vivo developmental competence. Epigenetic modifications of the chromatin template of black-footed cat donor cells and reconstructed embryos with epigenetic-modifying compounds enhanced in vitro development, and regulated the expression of pluripotent genes, but these epigenetic modifications did not improve in vivo developmental competence.

  1. A clinically applicable six-segmented foot model.

    Science.gov (United States)

    De Mits, Sophie; Segers, Veerle; Woodburn, Jim; Elewaut, Dirk; De Clercq, Dirk; Roosen, Philip

    2012-04-01

    We describe a multi-segmented foot model comprising lower leg, rearfoot, midfoot, lateral forefoot, medial forefoot, and hallux for routine use in a clinical setting. The Ghent Foot Model describes the kinematic patterns of functional units of the foot, especially the midfoot, to investigate patient populations where midfoot deformation or dysfunction is an important feature, for example, rheumatoid arthritis patients. Data were obtained from surface markers by a 6 camera motion capture system at 500 Hz. Ten healthy subjects walked barefoot along a 12 m walkway at self-selected speed. Joint angles (rearfoot to shank, midfoot to rearfoot, lateral and medial forefoot to midfoot, and hallux to medial forefoot) in the sagittal, frontal, and transverse plane are reported according to anatomically based reference frames. These angles were calculated and reported during the foot rollover phases in stance, detected by synchronized plantar pressure measurements. Repeated measurements of each subject revealed low intra-subject variability, varying between 0.7° and 2.3° for the minimum values, between 0.5° and 2.1° for the maximum values, and between 0.8° and 5.8° for the ROM. The described movement patterns were repeatable and consistent with biomechanical and clinical knowledge. As such, the Ghent Foot model permits intersegment, in vivo motion measurement of the foot, which is crucial for both clinical and research applications. Copyright © 2011 Orthopaedic Research Society.

  2. Foot preferences in wild-living ring-necked parakeets (Psittacula krameri, Psittacidae).

    Science.gov (United States)

    Randler, Christoph; Braun, Michael; Lintker, Stephanie

    2011-03-01

    Evidence for foot preferences has been reported in parrots and the majority of parrot species uses the left foot to hold and process food objects. Here we assessed the footedness of ring-necked parakeets (Psittacula krameri) in a wild-living non-native population in Heidelberg, Baden-Wurttemberg, Germany. Observations were made when parrots fed on catalpa trees Catalpa sp., with 20- to 50-cm-long fruits. Parakeets tend to bite off catalpa fruits with their beak, using one foot holding the fruit. Further, we established an experimental set-up (feeding location) and prepared pieces of apple in an adequate size to force parrots to handle the food with one foot. From 184 individuals feeding on the catalpa trees, 102 were recorded using the left foot and 82 the right foot. At the feeding location, 24 individuals were left-footed and 11 were right-footed. These observations suggest a foot preference in the ring-necked parakeet both on the population level and on the individual level.

  3. X-38 Drop Model: Landing Sequence Collage from Cessna Drop Test

    Science.gov (United States)

    1995-01-01

    This sequence of photographs shows a 4-foot-long model of NASA's X-38 gliding to earth after being dropped from a Cessna aircraft in late 1995. The model was used to test the ram-air parafoil landing system, which could allow for accurate and controlled landings of an emergency Crew Return Vehicle spacecraft returning to earth. The X-38 Crew Return Vehicle (CRV) research project is designed to develop the technology for a prototype emergency crew return vehicle, or lifeboat, for the International Space Station. The project is also intended to develop a crew return vehicle design that could be modified for other uses, such as a joint U.S. and international human spacecraft that could be launched on the French Ariane-5 Booster. The X-38 project is using available technology and off-the-shelf equipment to significantly decrease development costs. Original estimates to develop a capsule-type crew return vehicle were estimated at more than $2 billion. X-38 project officials have estimated that development costs for the X-38 concept will be approximately one quarter of the original estimate. Off-the-shelf technology is not necessarily 'old' technology. Many of the technologies being used in the X-38 project have never before been applied to a human-flight spacecraft. For example, the X-38 flight computer is commercial equipment currently used in aircraft and the flight software operating system is a commercial system already in use in many aerospace applications. The video equipment for the X-38 is existing equipment, some of which has already flown on the space shuttle for previous NASA experiments. The X-38's primary navigational equipment, the Inertial Navigation System/Global Positioning System, is a unit already in use on Navy fighters. The X-38 electromechanical actuators come from previous joint NASA, U.S. Air Force, and U.S. Navy research and development projects. Finally, an existing special coating developed by NASA will be used on the X-38 thermal tiles to

  4. Comparing the Effect of Foot Reflexology Massage, Foot Bath and Their Combination on Quality of Sleep in Patients with Acute Coronary Syndrome.

    Science.gov (United States)

    Rahmani, Ali; Naseri, Mahdi; Salaree, Mohammad Mahdi; Nehrir, Batool

    2016-12-01

    Introduction: Many patients in coronary care unit (CCU) suffer from decreased sleep quality caused by environmental and mental factors. This study compared the efficacy of foot reflexology massage, foot bath, and a combination of them on the quality of sleep of patients with acute coronary syndrome (ACS). Methods: This quasi-experimental study was implemented on ACS patients in Iran. Random sampling was used to divide the patients into four groups of 35 subjects. The groups were foot reflexology massage, foot bath, a combination of the two and the control group. Sleep quality was measured using the Veran Snyder-Halpern questionnaire. Data were analyzed by SPSS version 13. Results: The mean age of the four groups was 61.22 (11.67) years. The mean sleep disturbance in intervention groups (foot reflexology massage and foot bath groups) during the second and third nights was significantly less than before intervention. The results also showed a greater reduction in sleep disturbance in the combined group than in the other groups when compared to the control group. Conclusion: It can be concluded that the intervention of foot bath and massage are effective in reducing sleep disorders and there was a synergistic effect when used in combination. This complementary care method can be recommended to be implemented by CCU nurses.

  5. Total Site Heat Integration Considering Pressure Drops

    Directory of Open Access Journals (Sweden)

    Kew Hong Chew

    2015-02-01

    Full Text Available Pressure drop is an important consideration in Total Site Heat Integration (TSHI. This is due to the typically large distances between the different plants and the flow across plant elevations and equipment, including heat exchangers. Failure to consider pressure drop during utility targeting and heat exchanger network (HEN synthesis may, at best, lead to optimistic energy targets, and at worst, an inoperable system if the pumps or compressors cannot overcome the actual pressure drop. Most studies have addressed the pressure drop factor in terms of pumping cost, forbidden matches or allowable pressure drop constraints in the optimisation of HEN. This study looks at the implication of pressure drop in the context of a Total Site. The graphical Pinch-based TSHI methodology is extended to consider the pressure drop factor during the minimum energy requirement (MER targeting stage. The improved methodology provides a more realistic estimation of the MER targets and valuable insights for the implementation of the TSHI design. In the case study, when pressure drop in the steam distribution networks is considered, the heating and cooling duties increase by 14.5% and 4.5%.

  6. Drop size measurements in Venturi scrubbers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Alonso, D.; Azzopardi, B.J. [Nottingham Univ. (United Kingdom). Dept. of Chemical Engineering; Goncalves, J.A.S.; Coury, J.R. [Universidade Federal de Sao Carlos (Brazil). Departamento de Engenharia Quimica

    2001-07-01

    Venturi scrubbers are high efficiency gas cleaners in which suspended particles are removed from gas streams by drops formed by liquid atomisation, usually in the Venturi throat. The size of the drops formed are of fundamental importance to the performance of the equipment, both in terms of pressure drop and dust removal efficiency. In this study, drop sizes in a cylindrical laboratory-scale Venturi scrubber were measured using a laser diffraction technique. Gas velocity and liquid to gas ratios varied from 50 to 90 m/s and 0.5 to 2.0 1/m{sup 3}, respectively. Water was injected using two different arrangements: either as jets in the throat or as a film just upstream of the convergence. Drop size measurements were performed at three positions in the case of jet injection: two located along the throat, and the last one at the end of the diffuser. The present data shows that the Sauter mean diameter of the spray can be well correlated by the equation of Boll et al. (J. Air Pollut. Control Assoc. 24 (1974) 932). Drop size distributions are satisfactorily represented by a Rosin-Rammler function. This paper also provides a simple method for calculating the parameters of the Rosin-Rammler function. As a result of this work, drop sizes in Venturi scrubbers can be estimated with much higher accuracy. (Author)

  7. Etiology, pathophysiology and classifications of the diabetic Charcot foot

    Science.gov (United States)

    Papanas, Nikolaos; Maltezos, Efstratios

    2013-01-01

    In people with diabetes mellitus, the Charcot foot is a specific manifestation of peripheral neuropathy that may involve autonomic neuropathy with high blood flow to the foot, leading to increased bone resorption. It may also involve peripheral somatic polyneuropathy with loss of protective sensation and high risk of unrecognized acute or chronic minor trauma. In both cases, there is excess local inflammatory response to foot injury, resulting in local osteoporosis. In the Charcot foot, the acute and chronic phases have been described. The former is characterized by local erythema, edema, and marked temperature elevation, while pain is not a prominent symptom. In the latter, signs of inflammation gradually recede and deformities may develop, increasing the risk of foot ulceration. The most common anatomical classification describes five patterns, according to the localization of bone and joint pathology. This review article aims to provide a brief overview of the diabetic Charcot foot in terms of etiology, pathophysiology, and classification. PMID:23705058

  8. MR imaging of silicone breast implants: evaluation of prospective and retrospective interpretations and interobserver agreement.

    Science.gov (United States)

    Quinn, S F; Neubauer, N M; Sheley, R C; Demlow, T A; Szumowski, J

    1996-01-01

    MR imaging was used to evaluate the integrity of silicone breast implants in 54 women with 108 implants. MR images were interpreted by relatively inexperienced readers who tried to reproduce the experiences reported in the literature. The study examines the interobserver agreement using different diagnostic signs and the influence of experience on interpretation errors. Prospective and retrospective interpretations were compared with surgical findings at the time of explanation. Diagnostic indicators, including the linguine sign, the inverted tear drop sign, the C sign, water droplets mixed with silicone, and extracapsular globules of silicone, were evaluated for diagnostic efficacy and interobserver agreement. The prospective sensitivity and specificity were 87% and 78%, respectively. With the retrospective interpretations, the sensitivity and specificity increased to 93% and 92%, respectively. Most of the prospective false-positive interpretations were due to misinterpreting radial folds as signs of implant rupture. Six implants interpreted retrospectively as false positives had gross amounts of silicone around the implants at surgery but there were no obvious rents in the implant shells. There was fair to excellent interobserver agreement with the individual diagnostic signs except for extracapsular globules of silicone. All of the signs had specificities of greater than 90%. The sensitivities of the individual signs were less than the overall retrospective sensitivity. With experience, the sensitivity improved from 87% to 93% and the specificity improved from 78% to 92%. This study helps substantiate the use of diagnostic signs used by other authors to detect silicone loss from breast implants by MR imaging; however, questions remain as to the clinical role of MR imaging in evaluating implants for silicone loss.

  9. The Guyana Diabetes and Foot Care Project: Improved Diabetic Foot Evaluation Reduces Amputation Rates by Two-Thirds in a Lower Middle Income Country

    Science.gov (United States)

    Sibbald, R. Gary; Martin, Carlos

    2015-01-01

    Background. Type 2 diabetes is the fourth leading cause of death in Guyana, South America. A complex, interprofessional, quality improvement intervention to improve foot and diabetes care was rolled out in two phases. Methods & Findings. Phase 1: Establishment of an Interprofessional Diabetic Foot Center (DFC) of Excellence to improve foot care and reduce diabetes-related amputations at the national referral hospital. Phase 2: Regionalization to cover 90% of the Guyanese population and expansion to include improved management of diabetes and hypertension. Fourteen key opinion leaders were educated and 340 health care professionals from 97 facilities trained. Eight centers for the evaluation and treatment of foot ulcers were established and 7567 people with diabetes evaluated. 3452 participants had foot screening and 48% were deemed high risk; 10% of these had undocumented foot ulcers. There was a 68% reduction in rate of major amputations (P diabetes with women (F/M = 2.09) and increased risk of major amputation in men [odds ratio 2.16 (95% CI 1.83, 2.56)] were documented. Conclusions. This intervention improved foot care with reduction in major amputations sustained over 5 years. PMID:26089901

  10. Clinical evaluation of a novel dental implant system as single implants under immediate loading conditions - 4-month post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Trullenque-Eriksson, Anna; Blasone, Rodolfo; Malaguti, Giuliano; Gaffuri, Cristiano; Caneva, Marco; Minciarelli, Armando; Luongo, Giuseppe

    To evaluate the safety and clinical effectiveness of a novel dental implant system (GENESIS Implant System, Keystone Dental, Massachusetts, USA) using another dental implant system by the same manufacturer as a control (PRIMA Implant System, Keystone Dental). A total of 53 patients requiring at least two single crowns had their sites randomised according to a split-mouth design to receive both implant systems at six centres. If implants could be placed with a torque superior to 40 Ncm they were to be loaded immediately with provisional crowns, otherwise after 3 months of submerged healing. Provisional crowns were replaced by definitive crowns 4 months after initial loading, when the follow-up period for the initial part of this study was completed. Outcome measures were crown/implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, plaque score, marginal bleeding, patients and preference of the clinician. In total 53 PRIMA and 53 GENESIS implants were placed. Three patients dropped out but all of the remaining patients were followed up to 4-months post-loading. No PRIMA implant failed whereas four GENESIS implants failed. Only two complications were reported for PRIMA implants. There were no statistically significant differences for crown/implant failures (difference in proportions = 0.080; P (McNemar test) = 0.125) and complications (difference in proportions = -0.04; P (McNemar test) = 0.500) between the implant systems. There were no differences at 4-months post-loading for plaque (difference = -0.54, 95% CI: -3.01 to 1.93; P (Paired t-test) = 0.660), marginal bleeding (difference = -3.8, 95% CI: -7.63 to 0.019; P (Paired t-test) = 0.051), PES (difference = 0.47, 95% CI: -0.56 to 1.50; P (Paired t-test) = 0.365) and marginal bone level changes (difference in mm = -0.04, 95% CI: -0.33 to 0.26; P (Paired t-test) = 0.795). The majority of the patients (46) had no

  11. Modeling and stress analyses of a normal foot-ankle and a prosthetic foot-ankle complex.

    Science.gov (United States)

    Ozen, Mustafa; Sayman, Onur; Havitcioglu, Hasan

    2013-01-01

    Total ankle replacement (TAR) is a relatively new concept and is becoming more popular for treatment of ankle arthritis and fractures. Because of the high costs and difficulties of experimental studies, the developments of TAR prostheses are progressing very slowly. For this reason, the medical imaging techniques such as CT, and MR have become more and more useful. The finite element method (FEM) is a widely used technique to estimate the mechanical behaviors of materials and structures in engineering applications. FEM has also been increasingly applied to biomechanical analyses of human bones, tissues and organs, thanks to the development of both the computing capabilities and the medical imaging techniques. 3-D finite element models of the human foot and ankle from reconstruction of MR and CT images have been investigated by some authors. In this study, data of geometries (used in modeling) of a normal and a prosthetic foot and ankle were obtained from a 3D reconstruction of CT images. The segmentation software, MIMICS was used to generate the 3D images of the bony structures, soft tissues and components of prosthesis of normal and prosthetic ankle-foot complex. Except the spaces between the adjacent surface of the phalanges fused, metatarsals, cuneiforms, cuboid, navicular, talus and calcaneus bones, soft tissues and components of prosthesis were independently developed to form foot and ankle complex. SOLIDWORKS program was used to form the boundary surfaces of all model components and then the solid models were obtained from these boundary surfaces. Finite element analyses software, ABAQUS was used to perform the numerical stress analyses of these models for balanced standing position. Plantar pressure and von Mises stress distributions of the normal and prosthetic ankles were compared with each other. There was a peak pressure increase at the 4th metatarsal, first metatarsal and talus bones and a decrease at the intermediate cuneiform and calcaneus bones, in

  12. Sepsis from dropped clips at laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Hussain, Sarwat

    2001-01-01

    We report seven patients in whom five dropped surgical clips and two gallstones were visualized in the peritoneal cavity, on radiological studies. In two, subphrenic abscesses and empyemas developed as a result of dropped clips into the peritoneal cavity during or following laparoscopic cholecystectomy. In one of these two, a clip was removed surgically from the site of an abscess. In two other patients dropped gallstones, and in three, dropped clips led to no complications. These were seen incidentally on studies done for other indications. Abdominal abscess secondary to dropped gallstones is a well-recognized complication of laparoscopic cholecystectomy (LC). We conclude that even though dropped surgical clips usually do not cause problems, they should be considered as a risk additional to other well-known causes of post-LC abdominal sepsis

  13. Neuropathic diabetic foot ulcers – evidence-to-practice

    Directory of Open Access Journals (Sweden)

    Ndip A

    2012-02-01

    Full Text Available Agbor Ndip1–3, Leonard Ebah3,4, Aloysius Mbako51Department of Diabetes and Medicine, Manchester Royal Infirmary, Central Manchester Foundation Trust, UK; 2Department of Medicine, Royal Bolton Hospital, Bolton, UK; 3Cardiovascular Research Group, School of Biomedicine, University of Manchester, UK; 4Department of Renal Medicine, Manchester Royal Infirmary, Central Manchester Foundation Trust, UK; 5Department of Orthopaedic Surgery, Wrexham Maelor Hospital, Wales, UKAbstract: Foot ulcers and their attendant complications are disquietingly high in people with diabetes, a majority of whom have underlying neuropathy. This review examines the evidence base underpinning the prevention and management of neuropathic diabetic foot ulcers in order to inform best clinical practice. Since it may be impractical to ask patients not to weight-bear at all, relief of pressure through the use of offloading casting devices remains the mainstay for management of neuropathic ulcers, whilst provision of appropriate footwear is essential in ulcer prevention. Simple non-surgical debridement and application of hydrogels are both effective in preparing the wound bed for healthy granulation and therefore enhancing healing. Initial empirical antibiotic therapy for infected ulcers should cover the most common bacterial flora. There is limited evidence supporting the use of adjunctive therapies such as hyperbaric oxygen and cytokines or growth factors. In selected cases, recombinant human platelet-derived growth factor has been shown to enhance healing; however, its widespread use cannot be advised due to the availability of more cost-effective approaches. While patient education may be beneficial, the evidence base remains thin and conflicting. In conclusion, best management of foot ulcers is achieved by what is taken out of the foot (pressure, callus, infection, and slough rather than what is put on the foot (adjuvant treatment.Keywords: diabetic foot ulcers, neuropathic

  14. Epidemiology and outcome in patients of diabetic foot

    International Nuclear Information System (INIS)

    Ashraf, M.N.; Rehman, K.U.; Malik, K.I.; Iqbal, G.S.

    2011-01-01

    Background: The aim of study was detailed analysis of the presentation of diabetic foot ulcers, characteristics and predictors of outcome (incidence of amputation in neuropathic, ischemic, neuro ischemic) in patients presenting with diabetic foot at our hospital. Methods: This prospective analytic study was conducted from January 2009-August 2010 at POF Hospital Wah Cantt. Diabetic patients who presented with foot ulcers were enrolled in this study. Demographics of patients along with ulcer size, type, site and Grade according to Wagner Classification were recorded. Wounds were managed with daily dressings, nursing care and de-sloughing of necrotic tissue along with appropriate antibiotic cover. Patients were followed over period until wound healed completely or a lower limb amputation performed, the outcome noted and patient was deemed to have completed study. Results: One hundred and fifteen patients with mean age 55.46 +- 8.23 years, both male and female were included in this study. Out of 115 patients 111 patients had Type-II diabetes while only 4 presented with Type-I. Mean Duration of diabetes was 14.61 +- 2.17 years. With respect to underlying causes 18.3% foot ulcers were ischemic, 22.6% were neuropathic and 59% were neuro-ischemic. Median ulcer size was 74% of ulcer classified as Wagner grade-II and III while 24% were of Grade-V. Lower limb amputation were performed in 25% of patients whereas limb salvage achieved in 75% of patients with wounds healed (median healing time 5 (3-10 weeks). Conclusion: Preservation of the limb function without endangering the patient must be a goal of treating diabetic foot. Once foot amputation is successful, rehabilitation with orthotic or prosthetic devices may allow years of a functional extremity along with preventive measures like cessation of smoking, daily foot hygiene and foot inspection. (author)

  15. Foot ulcers in the diabetic patient, prevention and treatment

    Science.gov (United States)

    Wu, Stephanie C; Driver, Vickie R; Wrobel, James S; Armstrong, David G

    2007-01-01

    Lower extremity complications in persons with diabetes have become an increasingly significant public health concern in both the developed and developing world. These complications, beginning with neuropathy and subsequent diabetic foot wounds frequently lead to infection and lower extremity amputation even in the absence of critical limb ischemia. In order to diminish the detrimental consequences associated with diabetic foot ulcers, a com-mon-sense-based treatment approach must be implemented. Many of the etiological factors contributing to the formation of diabetic foot ulceration may be identified using simple, inexpensive equipment in a clinical setting. Prevention of diabetic foot ulcers can be accomplished in a primary care setting with a brief history and screening for loss of protective sensation via the Semmes-Weinstein monofilament. Specialist clinics may quantify neuropathy, plantar foot pressure, and assess vascular status with Doppler ultrasound and ankle-brachial blood pressure indices. These measurements, in conjunction with other findings from the history and physical examination, may enable clinicians to stratify patients based on risk and help determine the type of intervention. Other effective clinical interventions may include patient education, optimizing glycemic control, smoking cessation, and diligent foot care. Recent technological advanced combined with better understanding of the wound healing process have resulted in a myriad of advanced wound healing modalities in the treatment of diabetic foot ulcers. However, it is imperative to remember the fundamental basics in the healing of diabetic foot ulcers: adequate perfusion, debridement, infection control, and pressure mitigation. Early recognition of the etiological factors along with prompt management of diabetic foot ulcers is essential for successful outcome. PMID:17583176

  16. Foot Morphological Difference between Habitually Shod and Unshod Runners.

    Directory of Open Access Journals (Sweden)

    Yang Shu

    Full Text Available Foot morphology and function has received increasing attention from both biomechanics researchers and footwear manufacturers. In this study, 168 habitually unshod runners (90 males whose age, weight & height were 23±2.4 years, 66±7.1 kg & 1.68±0.13 m and 78 females whose age, weight & height were 22±1.8 years, 55±4.7 kg & 1.6±0.11 m (Indians and 196 shod runners (130 males whose age, weight & height were 24±2.6 years, 66±8.2 kg & 1.72±0.18 m and 66 females whose age, weight & height were 23±1.5 years, 54±5.6 kg & 1.62±0.15 m (Chinese participated in a foot scanning test using the easy-foot-scan (a three-dimensional foot scanning system to obtain 3D foot surface data and 2D footprint imaging. Foot length, foot width, hallux angle and minimal distance from hallux to second toe were calculated to analyze foot morphological differences. This study found that significant differences exist between groups (shod Chinese and unshod Indians for foot length (female p = 0.001, width (female p = 0.001, hallux angle (male and female p = 0.001 and the minimal distance (male and female p = 0.001 from hallux to second toe. This study suggests that significant differences in morphology between different ethnicities could be considered for future investigation of locomotion biomechanics characteristics between ethnicities and inform last shape and design so as to reduce injury risks and poor performance from mal-fit shoes.

  17. Micro-splashing by drop impacts

    KAUST Repository

    Thoroddsen, Sigurdur T; Takehara, Kohsei; Etoh, Takeharugoji

    2012-01-01

    We use ultra-high-speed video imaging to observe directly the earliest onset of prompt splashing when a drop impacts onto a smooth solid surface. We capture the start of the ejecta sheet travelling along the solid substrate and show how it breaks up immediately upon emergence from the underneath the drop. The resulting micro-droplets are much smaller and faster than previously reported and may have gone unobserved owing to their very small size and rapid ejection velocities, which approach 100 m s-1, for typical impact conditions of large rain drops. We propose a phenomenological mechanism which predicts the velocity and size distribution of the resulting microdroplets. We also observe azimuthal undulations which may help promote the earliest breakup of the ejecta. This instability occurs in the cusp in the free surface where the drop surface meets the radially ejected liquid sheet. © 2012 Cambridge University Press.

  18. Micro-splashing by drop impacts

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2012-07-18

    We use ultra-high-speed video imaging to observe directly the earliest onset of prompt splashing when a drop impacts onto a smooth solid surface. We capture the start of the ejecta sheet travelling along the solid substrate and show how it breaks up immediately upon emergence from the underneath the drop. The resulting micro-droplets are much smaller and faster than previously reported and may have gone unobserved owing to their very small size and rapid ejection velocities, which approach 100 m s-1, for typical impact conditions of large rain drops. We propose a phenomenological mechanism which predicts the velocity and size distribution of the resulting microdroplets. We also observe azimuthal undulations which may help promote the earliest breakup of the ejecta. This instability occurs in the cusp in the free surface where the drop surface meets the radially ejected liquid sheet. © 2012 Cambridge University Press.

  19. Pressure drop in ET-RR-1

    International Nuclear Information System (INIS)

    Khattab, M.; Mina, A.R.

    1990-01-01

    Measurements of pressure drop through a bundle comprising 16 rods and their lower arrangement grid as well as orifices similar to those of ET-RR-1 core have been done. Experiments are carried out under adiabatic turbulent flow conditions at about 35 degree C. Bundle Reynolds number range is 4 x 10 -2 x 10. Orifices of diameters 4.5, 3.25 or 2.5 cm. are mounted underneath the bundle. The bundle and lower grid pressure drop coefficients are 3.75 and 1.8 respectively. Orifices pressure drop coefficients are 2.65, 19.67 and 53.55 respectively. The ratio of bundle pressure drop to that of 4.5 cm. Orifice diameter is 1.415. The pressure drop coefficients are utilizer to calculate flow through bundles. The flow rate per bundle is 39.1, 20.4 or 13.1 m 3 /hr. Depending on orifice diameter

  20. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  1. Progress in detailed modelling of low foot and high foot implosion experiments on the National Ignition Facility

    Science.gov (United States)

    Clark, D. S.; Weber, C. R.; Eder, D. C.; Haan, S. W.; Hammel, B. A.; Hinkel, D. E.; Jones, O. S.; Kritcher, A. L.; Marinak, M. M.; Milovich, J. L.; Patel, P. K.; Robey, H. F.; Salmonson, J. D.; Sepke, S. M.

    2016-05-01

    Several dozen high convergence inertial confinement fusion ignition experiments have now been completed on the National Ignition Facility (NIF). These include both “low foot” experiments from the National Ignition Campaign (NIC) and more recent “high foot” experiments. At the time of the NIC, there were large discrepancies between simulated implosion performance and experimental data. In particular, simulations over predicted neutron yields by up to an order of magnitude, and some experiments showed clear evidence of mixing of ablator material deep into the hot spot that could not be explained at the time. While the agreement between data and simulation improved for high foot implosion experiments, discrepancies nevertheless remain. This paper describes the state of detailed modelling of both low foot and high foot implosions using 1-D, 2-D, and 3-D radiation hydrodynamics simulations with HYDRA. The simulations include a range of effects, in particular, the impact of the plastic membrane used to support the capsule in the hohlraum, as well as low-mode radiation asymmetries tuned to match radiography measurements. The same simulation methodology is applied to low foot NIC implosion experiments and high foot implosions, and shows a qualitatively similar level of agreement for both types of implosions. While comparison with the experimental data remains imperfect, a reasonable level of agreement is emerging and shows a growing understanding of the high-convergence implosions being performed on NIF.

  2. Progress in detailed modelling of low foot and high foot implosion experiments on the National Ignition Facility

    International Nuclear Information System (INIS)

    Clark, D S; Weber, C R; Eder, D C; Haan, S W; Hammel, B A; Hinkel, D E; Jones, O S; Kritcher, A L; Marinak, M M; Milovich, J L; Patel, P K; Robey, H F; Salmonson, J D; Sepke, S M

    2016-01-01

    Several dozen high convergence inertial confinement fusion ignition experiments have now been completed on the National Ignition Facility (NIF). These include both “low foot” experiments from the National Ignition Campaign (NIC) and more recent “high foot” experiments. At the time of the NIC, there were large discrepancies between simulated implosion performance and experimental data. In particular, simulations over predicted neutron yields by up to an order of magnitude, and some experiments showed clear evidence of mixing of ablator material deep into the hot spot that could not be explained at the time. While the agreement between data and simulation improved for high foot implosion experiments, discrepancies nevertheless remain. This paper describes the state of detailed modelling of both low foot and high foot implosions using 1-D, 2-D, and 3-D radiation hydrodynamics simulations with HYDRA. The simulations include a range of effects, in particular, the impact of the plastic membrane used to support the capsule in the hohlraum, as well as low-mode radiation asymmetries tuned to match radiography measurements. The same simulation methodology is applied to low foot NIC implosion experiments and high foot implosions, and shows a qualitatively similar level of agreement for both types of implosions. While comparison with the experimental data remains imperfect, a reasonable level of agreement is emerging and shows a growing understanding of the high-convergence implosions being performed on NIF. (paper)

  3. Preventative foot care in people with diabetes: Quality patient ...

    African Journals Online (AJOL)

    Foot ulceration and amputation cause extensive burden on individuals and health care systems. One of the reasons for the poor outcome of foot complications in developing countries is the lack of patient education. Due to the multi-factorial pathology of diabetic foot ulceration, the person with diabetes should receive health ...

  4. Contemporary Evaluation and Management of the Diabetic Foot

    Science.gov (United States)

    Sumpio, Bauer E.

    2012-01-01

    Foot problems in patients with diabetes remain a major public health issue and are the commonest reason for hospitalization of patients with diabetes with prevalence as high as 25%. Ulcers are breaks in the dermal barrier with subsequent erosion of underlying subcutaneous tissue that may extend to muscle and bone, and superimposed infection is a frequent and costly complication. The pathophysiology of diabetic foot disease is multifactorial and includes neuropathy, infection, ischemia, and abnormal foot structure and biomechanics. Early recognition of the etiology of these foot lesions is essential for good functional outcome. Managing the diabetic foot is a complex clinical problem requiring a multidisciplinary collaboration of health care workers to achieve limb salvage. Adequate off-loading, frequent debridement, moist wound care, treatment of infection, and revascularization of ischemic limbs are the mainstays of therapy. Even when properly managed, some of the foot ulcers do not heal and are arrested in a state of chronic inflammation. These wounds can frequently benefit from various adjuvants, such as aggressive debridement, growth factors, bioactive skin equivalents, and negative pressure wound therapy. While these, increasingly expensive, therapies have shown promising results in clinical trials, the results have yet to be translated into widespread clinical practice leaving a huge scope for further research in this field. PMID:24278695

  5. Behaviors Predicting Foot Lesions in Patients with Non-Insulin-Dependent Diabetes Mellitus

    OpenAIRE

    Suico, Jeffrey G; Marriott, Deanna J; Vinicor, Frank; Litzelman, Debra K

    1998-01-01

    Associations between specific foot-care behaviors and foot lesions in patients with non-insulin-dependent diabetes mellitus were prospectively investigated. Data from a randomized controlled trial for preventing diabetic foot lesions were analyzed as a prospective cohort using logistic regression. Independent variables included foot-care behaviors, patient self-foot examination, going barefoot, availability of foot-care assistance, and visits to health-care providers. The dependent variable w...

  6. Drop trampoline

    Science.gov (United States)

    Chantelot, Pierre; Coux, Martin; Clanet, Christophe; Quere, David

    2017-11-01

    Superhydrophobic substrates inspired from the lotus leaf have the ability to reflect impacting water drops. They do so very efficiently and contact lasts typically 10 ms for millimetric droplets. Yet unlike a lotus leaf most synthetic substrates are rigid. Focusing on the interplay between substrate flexibility and liquid repellency might allow us to understand the dynamic properties of natural surfaces. We perform liquid marbles impacts at velocity V onto thin ( 0.01 mm) stretched circular PDMS membranes. We obtain contact time reductions of up to 70%. The bouncing mechanism is drastically modified compared to that on a rigid substrate: the marble leaves the substrate while it is still spread in a disk shape as it is kicked upwards by the membrane. We show that the bouncing is controlled by an interplay between the dynamics of the drop and the membrane.

  7. Diagnostic value of newborn foot length to predict gestational age

    Directory of Open Access Journals (Sweden)

    Mutia Farah Fawziah

    2017-08-01

    Full Text Available Background  Identification of gestational age, especially within 48 hours of birth, is crucial for newborns, as the earlier preterm status is detected, the earlier the child can receive optimal management. Newborn foot length is an anthropometric measurement which is easy to perform, inexpensive, and potentially efficient for predicting gestational age. Objective  To analyze the diagnostic value of newborn foot length in predicting gestational age. Methods  This diagnostic study was performed between October 2016 and February 2017 in the High Care Unit of Neonates at Dr. Moewardi General Hospital, Surakarta. A total of 152 newborns were consecutively selected and underwent right foot length measurements before 96 hours of age. The correlation between newborn foot length to classify as full term and gestational age was analyzed with Spearman’s correlation test because of non-normal data distribution. The cut-off point of newborn foot length was calculated by receiver operating characteristic (ROC curve and diagnostic values of newborn foot length were analyzed by 2 x 2 table with SPSS 21.0 software. Results There were no significant differences between male and female newborns in terms of gestational age, birth weight, choronological age, and newborn foot length (P>0.05. Newborn foot length and gestational age had a significant correlation (r=0.53; P=0.000. The optimal cut-off newborn foot length to predict full term status was 7.1 cm. Newborn foot length below 7.1 cm had sensitivity 75%, specificity 98%, positive predictive value 94.3%, negative predictive value 90.6%, positive likelihood ratio 40.5, negative likelihood ratio 0.25, and post-test probability 94.29%, to predict preterm status in newborns. Conclusion  Newborn foot length can be used to predict gestational age, especially for the purpose of differentiating between preterm and full term newborns.

  8. Congenital hypertrophy of multiple intrinsic muscles of the foot.

    Science.gov (United States)

    Shiraishi, Tomohiro; Park, Susam; Niu, Atushi; Hasegawa, Hiromi

    2014-12-01

    Congenital hypertrophy of a single intrinsic muscle of the foot is rare, and as far as we know, only six cases have been reported. We describe a case of congenital anomaly that showed hypertrophy of multiple intrinsic muscles of the foot; the affected muscles were all the intrinsic muscles of the foot except the extensor digitorum brevis or extensor hallucis. Other tissues such as adipose tissue, nervous tissue, or osseous tissue showed no abnormalities. To reduce the volume of the foot we removed parts of the enlarged muscles.

  9. Drop Spreading with Random Viscosity

    Science.gov (United States)

    Xu, Feng; Jensen, Oliver

    2016-11-01

    Airway mucus acts as a barrier to protect the lung. However as a biological material, its physical properties are known imperfectly and can be spatially heterogeneous. In this study we assess the impact of these uncertainties on the rate of spreading of a drop (representing an inhaled aerosol) over a mucus film. We model the film as Newtonian, having a viscosity that depends linearly on the concentration of a passive solute (a crude proxy for mucin proteins). Given an initial random solute (and hence viscosity) distribution, described as a Gaussian random field with a given correlation structure, we seek to quantify the uncertainties in outcomes as the drop spreads. Using lubrication theory, we describe the spreading of the drop in terms of a system of coupled nonlinear PDEs governing the evolution of film height and the vertically-averaged solute concentration. We perform Monte Carlo simulations to predict the variability in the drop centre location and width (1D) or area (2D). We show how simulation results are well described (at much lower computational cost) by a low-order model using a weak disorder expansion. Our results show for example how variability in the drop location is a non-monotonic function of the solute correlation length increases. Engineering and Physical Sciences Research Council.

  10. Thermocapillary reorientation of Janus drops

    Science.gov (United States)

    Rosales, Rodolfo; Saenz, Pedro

    2017-11-01

    Janus drops, named after the Ancient Roman two-faced god, are liquid drops formed from two immiscible fluids. Experimental observations indicate that a Janus drop may re-orientate in response to an applied external thermal gradient due to the Marangoni effect. Depending on the angle between the interior interface and the direction of the temperature gradient, disparities in the physical properties of the constituent liquids may lead to asymmetries in the thermocapillary flow. As a result, the drop will move along a curved path until a torque-free configuration is achieved, point after which it will continue on a straight trajectory. Here, we present the results of a theoretical investigation of this realignment phenomenon in the Stokes regime and in the limit of non-deformable interfaces. A 3D semi-analytical method in terms of polar spherical harmonics is developed to characterize and rationalize the hydrodynamic response (forces and torques), flow (velocity and temperature distribution) and trajectory of a Janus drop moving during the temperature-driven reorientation process. Furthermore, we discuss how this phenomenon may be exploited to develop dynamically reconfigurable micro-lenses. This work was partially supported by the US National Science Foundation through Grants DMS-1614043 and DMS-1719637.

  11. Are we telling the diabetic patients adequately about foot care

    International Nuclear Information System (INIS)

    Ali, R.; Din, M.J.U.; Jadoon, R.J.; Farooq, U.; Alam, M.A.; Qureshi, A.; Shah, S.U.

    2016-01-01

    Background: Diabetes mellitus affects more than 285 million people worldwide. The prevalence is expected to rise to 439 million by the year 2030. Diabetic foot ulcers precede 84 percentage of non-traumatic amputations in diabetics. One lower limb is lost every 30 seconds around the world because of diabetic foot ulceration. Apart from being lengthy, the treatment of diabetic foot is also very expensive. There is very limited emphasis on foot care in diabetic patients. Even in developed countries patients feel that they do not have adequate knowledge about foot care. This study was conducted to find out how much information is imparted by doctors to diabetic patients about foot care. Methods: This cross-sectional study was conducted in admitted patients of the Department of Medicine, DHQ Hospital, Abbottabad from May 2014 to June 2015. 139 diabetic patients more than 25 years of age were included by non-probability consecutive sampling. Results: The mean age was 57.17 ( percentage 11.1) years. 35.3 percentage of patients were male and 64.7 percentage were female. The mean duration of diabetes in patients was 8.3 (±6) years. Only 36.7 percentage of patients said that their doctor told them about foot care. Less than 40 percentage of patients knew that they should daily inspect their feet, wash them with gentle warm water, and dry them afterwards. Only 25.2 percentage of the participants knew how to manage corns or calluses on feet. 66.5 percentage of patients knew that they should not walk bare foot. Overall, 63 percentage of our patients had less than 50 percentage knowledge of the 11 points regarding foot care that the investigators asked them. Conclusion: Diabetic foot problems are the one of the costliest, most disabling and disheartening complication of diabetes mellitus. Doctors are not properly telling diabetic patients about foot care. There is a deficiency of knowledge among the diabetic patients regarding foot care. (author)

  12. Chinese cross-cultural adaptation and validation of the Foot Function Index as tool to measure patients with foot and ankle functional limitations.

    Science.gov (United States)

    González-Sánchez, Manuel; Ruiz-Muñoz, Maria; Li, Guang Zhi; Cuesta-Vargas, Antonio I

    2017-05-11

    To perform a cross-cultural adaptation and validation of the Foot Function Index (FFI) questionnaire to develop the Chinese version. Three hundred and six patients with foot and ankle neuromusculoskeletal diseases participated in this observational study. Construct validity, internal consistency and criterion validity were calculated for the FFI Chinese version after the translation and transcultural adaptation process. Internal consistency ranged from 0.996 to 0.998. Test-retest analysis ranged from 0.985 to 0.994; minimal detectable change 90: 2.270; standard error of measurement: 0.973. Load distribution of the three factors had an eigenvalue greater than 1. Chi-square value was 9738.14 (p Foot Function Index (Taiwan Version), Short-Form 12 (Version 2) and EuroQol-5D were used for criterion validity. Factors 1 and 2 showed significant correlation with 15/16 and 14/16 scales and subscales, respectively. Foot Function Index Chinese version psychometric characteristics were good to excellent. Chinese researchers and clinicians may use this tool for foot and ankle assessment and monitoring. Implications for rehabilitation A cross-cultural adaptation of the FFI has been done from original version to Chinese. Consistent results and satisfactory psychometric properties of the Foot Function Index Chinese version have been reported. For Chinese speaking researcher and clinician FFI-Ch could be used as a tool to assess patients with foot disease.

  13. Comparing the Effect of Foot Reflexology Massage, Foot Bath and Their Combination on Quality of Sleep in Patients with Acute Coronary Syndrome

    Directory of Open Access Journals (Sweden)

    Ali Rahmani

    2016-12-01

    Full Text Available Introduction: Many patients in coronary care unit (CCU suffer from decreased sleep quality caused by environmental and mental factors. This study compared the efficacy of foot reflexology massage, foot bath, and a combination of them on the quality of sleep of patients with acute coronary syndrome (ACS. Methods: This quasi-experimental study was implemented on ACS patients in Iran. Random sampling was used to divide the patients into four groups of 35 subjects. The groups were foot reflexology massage, foot bath, a combination of the two and the control group. Sleep quality was measured using the Veran Snyder-Halpern questionnaire. Data were analyzed by SPSS version 13. Results: The mean age of the four groups was 61.22 (11.67 years. The mean sleep disturbance in intervention groups (foot reflexology massage and foot bath groups during the second and third nights was significantly less than before intervention. The results also showed a greater reduction in sleep disturbance in the combined group than in the other groups when compared to the control group. Conclusion: It can be concluded that the intervention of foot bath and massage are effective in reducing sleep disorders and there was a synergistic effect when used in combination. This complementary care method can be recommended to be implemented by CCU nurses.

  14. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  15. The Diabetic Foot Attack: "'Tis Too Late to Retreat!"

    Science.gov (United States)

    Vas, Prashanth R J; Edmonds, Michael; Kavarthapu, Venu; Rashid, Hisham; Ahluwalia, Raju; Pankhurst, Christian; Papanas, Nikolaos

    2018-03-01

    The "diabetic foot attack" is one of the most devastating presentations of diabetic foot disease, typically presenting as an acutely inflamed foot with rapidly progressive skin and tissue necrosis, at times associated with significant systemic symptoms. Without intervention, it may escalate over hours to limb-threatening proportions and poses a high amputation risk. There are only best practice approaches but no international protocols to guide management. Immediate recognition of a typical infected diabetic foot attack, predominated by severe infection, with prompt surgical intervention to debride all infected tissue alongside broad-spectrum antibiotic therapy is vital to ensure both limb and patient survival. Postoperative access to multidisciplinary and advanced wound care therapies is also necessary. More subtle forms exist: these include the ischemic diabetic foot attack and, possibly, in a contemporary categorization, acute Charcot neuroarthropathy. To emphasize the importance of timely action especially in the infected and ischemic diabetic foot attack, we revisit the concept of "time is tissue" and draw parallels with advances in acute myocardial infarction and stroke care. At the moment, international protocols to guide management of severe diabetic foot presentations do not specifically use the term. However, we believe that it may help increase awareness of the urgent actions required in some situations.

  16. Foot orgasm syndrome: a case report in a woman.

    Science.gov (United States)

    Waldinger, Marcel D; de Lint, Govert J; van Gils, Ad P G; Masir, Farhad; Lakke, Egbert; van Coevorden, Ruben S; Schweitzer, Dave H

    2013-08-01

    Spontaneous orgasm triggered from inside the foot has so far not been reported in medical literature. The study aims to report orgasmic feelings in the left foot of a woman. A woman presented with complaints of undesired orgasmic sensations originating in her left foot. In-depth interview, physical examination, sensory testing, magnetic resonance imaging (MRI-scan), electromyography (EMG), transcutaneous electrical nerve stimulation (TENS), and blockade of the left S1 dorsal root ganglion were performed. The main outcomes are description of this clinical syndrome, results of TENS application, and S1 dorsal root ganglion blockade. Subtle attenuation of sensory amplitudes of the left suralis, and the left medial and lateral plantar nerve tracts was found at EMG. MRI-scan disclosed no foot abnormalities. TENS at the left metatarso-phalangeal joint-III of the left foot elicited an instant orgasmic sensation that radiated from plantar toward the vagina. TENS applied to the left side of the vagina elicited an orgasm that radiated to the left foot. Diagnostic blockade of the left S1 dorsal root ganglion with 0.8 mL bupivacaine 0.25 mg attenuated the frequency and intensity of orgasmic sensation in the left foot with 50% and 80%, respectively. Additional therapeutic blockade of the same ganglion with 0.8 mL bupivacaine 0.50 mg combined with pulsed radiofrequency treatment resulted in a complete disappearance of the foot-induced orgasmic sensations. Foot orgasm syndrome (FOS) is descibed in a woman. Blockade of the left S1 dorsal root ganglion alleviated FOS. It is hypothesized that FOS, occurring 1.5 years after an intensive care emergency, was caused by partial nerve regeneration (axonotmesis), after which afferent (C-fiber) information from a small reinnervated skin area of the left foot and afferent somatic and autonomous (visceral) information from the vagina on at least S1 spinal level is misinterpreted by the brain as being solely information originating from

  17. A musculoskeletal foot model for clinical gait analysis.

    Science.gov (United States)

    Saraswat, Prabhav; Andersen, Michael S; Macwilliams, Bruce A

    2010-06-18

    Several full body musculoskeletal models have been developed for research applications and these models may potentially be developed into useful clinical tools to assess gait pathologies. Existing full-body musculoskeletal models treat the foot as a single segment and ignore the motions of the intrinsic joints of the foot. This assumption limits the use of such models in clinical cases with significant foot deformities. Therefore, a three-segment musculoskeletal model of the foot was developed to match the segmentation of a recently developed multi-segment kinematic foot model. All the muscles and ligaments of the foot spanning the modeled joints were included. Muscle pathways were adjusted with an optimization routine to minimize the difference between the muscle flexion-extension moment arms from the model and moment arms reported in literature. The model was driven by walking data from five normal pediatric subjects (aged 10.6+/-1.57 years) and muscle forces and activation levels required to produce joint motions were calculated using an inverse dynamic analysis approach. Due to the close proximity of markers on the foot, small marker placement error during motion data collection may lead to significant differences in musculoskeletal model outcomes. Therefore, an optimization routine was developed to enforce joint constraints, optimally scale each segment length and adjust marker positions. To evaluate the model outcomes, the muscle activation patterns during walking were compared with electromyography (EMG) activation patterns reported in the literature. Model-generated muscle activation patterns were observed to be similar to the EMG activation patterns. Published by Elsevier Ltd.

  18. Self-efficacy of foot care behaviour of elderly patients with diabetes

    Directory of Open Access Journals (Sweden)

    Maizatul Nadwa Mohd Razi

    2017-08-01

    Full Text Available Introduction: Elderly patients with diabetes are at a high risk of contracting diabetic foot problems. Self-efficacy is essential to help improve foot care behaviour. Aim: To identify levels of self-efficacy and foot care behaviour and their relationship with demographic characteristics in elderly patients with diabetes Methods: A cross-sectional study was conducted in two general hospitals in Malaysia from May to June 2015. Diabetes patients aged 60 years with specific inclusion criteria were invited to participate in this study. The respondents were interviewed using a set of validated questionnaires. Data were analysed with descriptive and inferential statistics (multiple linear regression using Statistical Package for the Social Sciences version 20.0. Results: Levels of foot self-efficacy (mean+31.39; standard deviation=7.76 and foot care behaviour (mean=25.37; SD=5.88 were high. There was a positive significant relationship between foot selfefficacy (β = 0.41, p < 0.001 and gender (β = 0.30, p < 0.001 with foot care behaviour. Conclusion: Self-efficacy can be incorporated in diabetes education to improve foot care behaviour. High-risk patients should be taught proper foot inspection and protection as well as the merits of skin care to prevent the occurrence of diabetic foot problems.

  19. Age determination enhanced by embryonic foot bud and foot plate measurements in relation to Carnegie stages, and the influence of maternal cigarette smoking.

    Science.gov (United States)

    Lutterodt, M C; Rosendahl, M; Yding Andersen, C; Skouby, S O; Byskov, A G

    2009-08-01

    Reliable age determination of first-trimester human embryos and fetuses is an important parameter for clinical use and basic science. Age determination by ultrasound or morphometric parameters of embryos 4-6 weeks post conception (p.c.) have been questioned, and more accurate methods are required. Data on whether and how maternal smoking and alcohol consumption influence embryonic and fetal foot growth is also lacking. Embryonic tissue from 102 first-trimester legal abortions (aged 35-69 days p.c.) were collected. All women answered a questionnaire concerning smoking and drinking habits, and delivered a urine sample for cotinine analysis. Embryonic age was evaluated by vaginal ultrasound measurements and by post-termination foot length and compared with the Carnegie stages. Foot bud and foot plate were defined and measured as foot length in embryos aged 35-47 days p.c. (range 0.8-2.1 mm). In embryos and fetuses aged 41-69 days p.c., heel-toe length was measured (range 2.5-7.5 mm). We found a significant linear correlation between foot length and age. Morphology of the feet was compared visually with the Carnegie collection, and we found that the mean ages of the two collections correlated well. Foot length was independent of gender, Environmental Tobacco Smoke, maternal smoking and alcohol consumption. Foot length correlated linearly to embryonic and foetal age, and was unaffected by gender, ETS, maternal smoking and alcohol consumption.

  20. A New Mobile Application for Standardizing Diabetic Foot Images.

    Science.gov (United States)

    Yap, Moi Hoon; Chatwin, Katie E; Ng, Choon-Ching; Abbott, Caroline A; Bowling, Frank L; Rajbhandari, Satyan; Boulton, Andrew J M; Reeves, Neil D

    2018-01-01

    We describe the development of a new mobile app called "FootSnap," to standardize photographs of diabetic feet and test its reliability on different occasions and between different operators. FootSnap was developed by a multidisciplinary team for use with the iPad. The plantar surface of 30 diabetic feet and 30 nondiabetic control feet were imaged using FootSnap on two separate occasions by two different operators. Reproducibility of foot images was determined using the Jaccard similarity index (JSI). High intra- and interoperator reliability was demonstrated with JSI values of 0.89-0.91 for diabetic feet and 0.93-0.94 for control feet. Similarly high reliability between groups indicates FootSnap is appropriate for longitudinal follow-ups in diabetic feet, with potential for monitoring pathology.

  1. CPAS Preflight Drop Test Analysis Process

    Science.gov (United States)

    Englert, Megan E.; Bledsoe, Kristin J.; Romero, Leah M.

    2015-01-01

    Throughout the Capsule Parachute Assembly System (CPAS) drop test program, the CPAS Analysis Team has developed a simulation and analysis process to support drop test planning and execution. This process includes multiple phases focused on developing test simulations and communicating results to all groups involved in the drop test. CPAS Engineering Development Unit (EDU) series drop test planning begins with the development of a basic operational concept for each test. Trajectory simulation tools include the Flight Analysis and Simulation Tool (FAST) for single bodies, and the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulation for the mated vehicle. Results are communicated to the team at the Test Configuration Review (TCR) and Test Readiness Review (TRR), as well as at Analysis Integrated Product Team (IPT) meetings in earlier and intermediate phases of the pre-test planning. The ability to plan and communicate efficiently with rapidly changing objectives and tight schedule constraints is a necessity for safe and successful drop tests.

  2. Gait kinematics of subjects with ankle instability using a multisegmented foot model.

    Science.gov (United States)

    De Ridder, Roel; Willems, Tine; Vanrenterghem, Jos; Robinson, Mark; Pataky, Todd; Roosen, Philip

    2013-11-01

    Many patients who sustain an acute lateral ankle sprain develop chronic ankle instability (CAI). Altered ankle kinematics have been reported to play a role in the underlying mechanisms of CAI. In previous studies, however, the foot was modeled as one rigid segment, ignoring the complexity of the ankle and foot anatomy and kinematics. The purpose of this study was to evaluate stance phase kinematics of subjects with CAI, copers, and controls during walking and running using both a rigid and a multisegmented foot model. Foot and ankle kinematics of 77 subjects (29 subjects with self-reported CAI, 24 copers, and 24 controls) were measured during barefoot walking and running using a rigid foot model and a six-segment Ghent Foot Model. Data were collected on a 20-m-long instrumented runway embedded with a force plate and a six-camera optoelectronic system. Groups were compared using statistical parametric mapping. Both the CAI and the coper group showed similar differences during midstance and late stance compared with the control group (P foot segment showed a more everted position during walking compared with the control group. Based on the Ghent Foot Model, the rear foot also showed a more everted position during running. The medial forefoot showed a more inverted position for both running and walking compared with the control group. Our study revealed significant midstance and late stance differences in rigid foot, rear foot, and medial forefoot kinematics The multisegmented foot model demonstrated intricate behavior of the foot that is not detectable with rigid foot modeling. Further research using these models is necessary to expand knowledge of foot kinematics in subjects with CAI.

  3. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    Science.gov (United States)

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention

  4. A Midterm Review of Lesser Toe Arthrodesis With an Intramedullary Implant.

    Science.gov (United States)

    Harmer, James Lee; Wilkinson, Anthony; Maher, Anthony John

    2017-10-01

    Lesser toe deformities are one of the most common conditions encountered by podiatric surgeons. When conservative treatments fail surgical correction is indicated. Many surgical options have been described to address the complex nature of these deformities but no perfect solution has been reported to date. However, with the continued advancement of internal fixation technology, interphalangeal joint (IPJ) arthrodesis with an intramedullary implant may be a good option. This retrospective study presents patient reported outcomes and complications at 6 months and 3 years following lesser toe proximal interphalangeal joint (PIPJ) arthrodesis with a polyketone intrameduallary implant (Toe Grip, Orthosolutions, UK). Between September 2011 and November 2012, a total of 38 patients attended for second toe PIPJ arthrodesis by means of the Toe Grip device. At 6 months postoperation, 94.7% of patients and at 3 years postoperation, 92.8% of patients felt that their original complaint was better or much better. Health-related quality of life scores continued to improve overtime as measured by the Manchester Oxford Foot Questionnaire. Complications were generally observational and asymptomatic. The most common complications were floating toes (17.8%), mallet deformities (14.2%), metatarsalgia (17.8%), and transverse plane deformity of the toe (10.7%). This study demonstrates excellent patient-eported outcomes with minimal symptomatic complications making the "Toe Grip" implant a safe and effective alternative fixation device for IPJ arthrodesis when dealing with painful digital deformities. Therapeutic, Level IV: Case series.

  5. Blood drop patterns: Formation and applications.

    Science.gov (United States)

    Chen, Ruoyang; Zhang, Liyuan; Zang, Duyang; Shen, Wei

    2016-05-01

    The drying of a drop of blood or plasma on a solid substrate leads to the formation of interesting and complex patterns. Inter- and intra-cellular and macromolecular interactions in the drying plasma or blood drop are responsible for the final morphologies of the dried patterns. Changes in these cellular and macromolecular components in blood caused by diseases have been suspected to cause changes in the dried drop patterns of plasma and whole blood, which could be used as simple diagnostic tools to identify the health of humans and livestock. However, complex physicochemical driving forces involved in the pattern formation are not fully understood. This review focuses on the scientific development in microscopic observations and pattern interpretation of dried plasma and whole blood samples, as well as the diagnostic applications of pattern analysis. Dried drop patterns of plasma consist of intricate visible cracks in the outer region and fine structures in the central region, which are mainly influenced by the presence and concentration of inorganic salts and proteins during drying. The shrinkage of macromolecular gel and its adhesion to the substrate surface have been thought to be responsible for the formation of the cracks. Dried drop patterns of whole blood have three characteristic zones; their formation as functions of drying time has been reported in the literature. Some research works have applied engineering treatment to the evaporation process of whole blood samples. The sensitivities of the resultant patterns to the relative humidity of the environment, the wettability of the substrates, and the size of the drop have been reported. These research works shed light on the mechanisms of spreading, evaporation, gelation, and crack formation of the blood drops on solid substrates, as well as on the potential applications of dried drop patterns of plasma and whole blood in diagnosis. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  6. Ascending infection of foot tendons in diabetic patients.

    Science.gov (United States)

    Mismar, Ayman; Yousef, Mohammad; Badran, Darwish; Younes, Nidal

    2013-12-01

    Bone and soft tissue infection in the foot of diabetic patients is a well-described issue in the literature. A sound anatomical knowledge of the foot anatomy and compartments is mandatory to understand the mechanisms of infection spread. We describe four cases of diabetic foot infection complicated by long ascending infection. All did not respond initially to antibiotic treatment and the usual surgical debridement and were cured only after excision of the infected tendons. We highlight a rare but serious complication of the diabetic foot disease not commonly seen by the surgical community. We hope that this report raises the awareness of this condition so that a prompt diagnosis is made and appropriate treatment started, thereby reducing the risk of major lower limb amputations.

  7. Influence of antibacterial therapy on bone scan indices at foot inflammation in diabetes mellitus accompanied by diabetic foot syndrome

    International Nuclear Information System (INIS)

    Slavnov, V.M.; Bolgars'ka, S.V.; Taran, E.V.; Markov, V.V.

    2004-01-01

    The influence of antibacterial therapy on bone scan indices at foot inflammation in patients with diabetes mellitus (DM) accompanied by diabetic foot syndrome was studied. Bone scan was performed using scintillation tomographic gamma-camera hours after intravenous injection of 99m Tc-methylene diphosphonate

  8. Angiography in the region of the foot

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E.

    1984-06-01

    It is reported on technique, incidence and findings of angiography of the foot which provided magnifying angiography and non-ionic contrast media are used, is especially qualified for the differentiation of diabetic and non-diabetic angiopathies as well as for the identification of peripherical embolizations and digital arterial occlusions at thrombocytosis or polycythemia. The arteries of the foot represent the peripherical outflow at peripherical reconstructive performances at the lower leg and have to be studied prior to such reconstructive surgical interventions. The different localization of arterial obliterations and changes of the walls in diabetics of stage I-IV according to Fontaine shows the particularly large number of vascular-pathological findings in arteries of the lower leg and foot in diabetics with arterial occlusive diseases of stage III and IV. Therefore, the unfavourable prognoses of arterial occlusive diseases in diabetics have also to be made for peripherical arterial obliterations of the foot and lower leg.

  9. Angiography in the region of the foot

    International Nuclear Information System (INIS)

    Zeitler, E.

    1984-01-01

    It is reported on technique, incidence and findings of angiography of the foot which provided magnifying angiography and non-ionic contrast media are used, is especially qualified for the differentiation of diabetic and non-diabetic angiopathies as well as for the identification of peripherical embolizations and digital arterial occlusions at thrombocytosis or polycythemia. The arteries of the foot represent the peripherical outflow at peripherical reconstructive performances at the lower leg and have to be studied prior to such reconstructive surgical interventions. The different localization of arterial obliterations and changes of the walls in diabetics of stage I-IV according to Fontaine shows the particularly large number of vascular-pathological findings in arteries of the lower leg and foot in diabetics with arterial occlusive diseases of stage III and IV. Therefore, the unfavourable prognoses of arterial occlusive diseases in diabetics have also to be made for peripherical arterial obliterations of the foot and lower leg. (orig.) [de

  10. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search...... of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  11. Imaging diagnostics of the foot; Bildgebende Diagnostik des Fusses

    Energy Technology Data Exchange (ETDEWEB)

    Szeimies, Ulrike; Staebler, Axel [Radiologie in Muenchen-Harlaching, Muenchen (Germany); Walther, Markus (eds.) [Schoen-Klinik Muenchen-Harlaching, Muenchen (Germany). Zentrum fuer Fuss- und Sprunggelenkchirurgie

    2012-11-01

    The book on imaging diagnostics of the foot contains the following chapters: (1) Imaging techniques. (2) Clinical diagnostics. (3) Ankle joint and hind foot. (4) Metatarsus. (5) Forefoot. (6) Pathology of plantar soft tissue. (7) Nervous system diseases. (8) Diseases without specific anatomic localization. (9) System diseases including the foot. (10) Tumor like lesions. (11) Normative variants.

  12. A new approach to children's footwear based on foot type classification.

    Science.gov (United States)

    Mauch, M; Grau, S; Krauss, I; Maiwald, C; Horstmann, T

    2009-08-01

    Current shoe designs do not allow for the comprehensive 3-D foot shape, which means they are unable to reproduce the wide variability in foot morphology. Therefore, the purpose of this study was to capture these variations of children's feet by classifying them into groups (types) and thereby provide a basis for their implementation in the design of children's shoes. The feet of 2867 German children were measured using a 3-D foot scanner. Cluster analysis was then applied to classify the feet into three different foot types. The characteristics of these foot types differ regarding their volume and forefoot shape both within and between shoe sizes. This new approach is in clear contrast to previous systems, since it captures the variability of foot morphology in a more comprehensive way by using a foot typing system and therefore paves the way for the unimpaired development of children's feet. Previous shoe systems do not allow for the wide variations in foot morphology. A new approach was developed regarding different morphological foot types based on 3-D measurements relevant in shoe construction. This can be directly applied to create specific designs for children's shoes.

  13. Benign and malignant tumors of the foot and ankle

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Adam D.; Datir, Abhijit; Langley, Travis [Emory University Hospital, Department of Radiology, Section of Musculoskeletal Imaging, Atlanta, GA (United States); Tresley, Jonathan [University of Wisconsin, Department of Radiology, Madison, WI (United States); Clifford, Paul D.; Jose, Jean; Subhawong, Ty K. [University of Miami, Department of Radiology, Miami, FL (United States)

    2016-03-15

    Pain and focal masses in the foot and ankle are frequently encountered and often initiate a workup including imaging. It is important to differentiate benign lesions from aggressive benign or malignant lesions. In this review, multiple examples of osseous and soft tissue tumors of the foot and ankle will be presented. Additionally, the compartmental anatomy of the foot and ankle will be discussed in terms of its relevance for percutaneous biopsy planning and eventual surgery. Finally, a general overview of the surgical management of benign, benign aggressive and malignant tumors of the foot and ankle will be discussed. (orig.)

  14. Foot deformities, function in the lower extremities, and plantar pressure in patients with diabetes at high risk to develop foot ulcers

    OpenAIRE

    Tang, Ulla Hellstrand; Z?gner, Roland; Lisovskaja, Vera; Karlsson, Jon; Hagberg, Kerstin; Tranberg, Roy

    2015-01-01

    Objective: Foot deformities, neuropathy, and dysfunction in the lower extremities are known risk factors that increase plantar peak pressure (PP) and, as a result, the risk of developing foot ulcers in patients with diabetes. However, knowledge about the prevalence of these factors is still limited. The aim of the present study was to describe the prevalence of risk factors observed in patients with diabetes without foot ulcers and to explore possible connections between the risk factors and ...

  15. Immediately loaded zygomatic implants vs conventional dental implants in augmented atrophic maxillae: 4 months post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Davó, Rubén; Marti-Pages, Carlos; Ferrer-Fuertes, Ada; Barausse, Carlo; Pistilli, Roberto; Ippolito, Daniela Rita; Felice, Pietro

    2018-01-01

    To compare the clinical outcome of immediately loaded cross-arch maxillary prostheses supported by zygomatic implants vs conventional implants placed in augmented bone. A total of 71 edentulous patients with severely atrophic maxillas, who did not have sufficient bone volume to place dental implants or when it was possible to place only two implants in the front area (minimal diameter 3.5 mm and length of 8 mm) and less than 4.0 mm of bone height subantrally, were randomised according to a parallel group design. They (35 patients) received zygomatic implants to be loaded immediately vs grafting with a xenograft, followed, after 6 months of graft consolidation, by the placement of six to eight conventional dental implants, submerged for 4 months (36 patients). To be loaded immediately, zygomatic implants had to be inserted with an insertion torque superior to 40 Ncm. Screw-retained, metal-reinforced, acrylic provisional prostheses were provided to be replaced by definitive Procera Implant Bridge Titanium prostheses (Nobel Biocare, Göteborg, Sweden) with ceramic or acrylic veneer materials 4 months after initial loading. Outcome measures were: prosthesis, implant and augmentation failures, any complications, quality of life (OHIP-14), the number of days that patients experienced total or partial impaired activity, time to function, and number of dental visits, assessed by independent assessors. Patients were followed up to 4 months after loading. No augmentation procedure failed. Three patients dropped out from the augmentation group. Six prostheses could not be delivered or failed in the augmentation group vs one prosthesis in the zygomatic group, the difference being statistically significant (difference in proportions = 15.32%; P = 0.04; 95% CI: 0.23 to 31.7). Eight patients lost 35 implants in the augmentation group vs three implants in one patient from the zygomatic group, the difference being statistically significant (difference in proportions = 21.38%; P = 0

  16. Comorbidities associated with Egyptian diabetic foot disease subtypes

    Directory of Open Access Journals (Sweden)

    Mary N. Rizk

    2013-01-01

    Conclusion Special attention should be paid toward the identification of patients who are at risk of foot ulceration to help prevent foot problems. Comorbid conditions must also be identified early and managed aggressively.

  17. Controlled Systemic Delivery by Polymeric Implants Enhances Tissue and Plasma Curcumin Levels Compared with Oral Administration

    Science.gov (United States)

    Bansal, Shyam S.; Kausar, Hina; Vadhanam, Manicka V.; Ravoori, Srivani; Gupta, Ramesh C.

    2012-01-01

    Curcumin possess potent anti-inflammatory and anti-proliferative activities but with poor biopharmaceutical attributes. To overcome these limitations, curcumin implants were developed and tissue (plasma, brain and liver) curcumin concentrations were measured in female ACI rats for 3 months. Biological efficacy of tissue levels achieved was analyzed by modulation of hepatic cytochromes. Curcumin implants exhibited diffusion-mediated biphasic release pattern with ~2-fold higher in vivo release as compared to in vitro. Plasma curcumin concentration from implants was ~3.3 ng/ml on day 1 which dropped to ~0.2 ng/ml after 3 months whereas only 0.2–0.3 ng/ml concentration was observed from 4–12 days with diet and was undetected subsequently. Almost 10 fold higher curcumin levels were observed in brain on day 1 from implants compared with diet (30.1±7.3 vs 2.7±0.8 ng/g) and were higher even after 90 days (7.7±3.8 vs 2.2±0.8 ng/g). Although, curcumin levels were similar in liver from both the routes (~25–30 ng/g from day 1–4 and ~10–15 ng/g at 90 days), implants were more efficacious in altering hepatic CYP1A1 levels and CYP3A4 activity at ~28 fold lower doses. Curcumin implants provided much higher plasma and tissue concentrations and are a viable alternative for delivery of curcumin to various organs like brain. PMID:22227368

  18. Structural and functional biological materials: Abalone nacre, sharp materials, and abalone foot adhesion

    Science.gov (United States)

    Lin, Albert Yu-Min

    A three-part study of lessons from nature is presented through the examination of various biological materials, with an emphasis on materials from the mollusk Haliotis rufescens, commonly referred to as the red abalone. The three categories presented are: structural hierarchy, self-assembly, and functionality. Ocean mollusk shells are composed of aragonite/calcite crystals interleaved with layers of a visco-elastic protein, having dense, tailored structures with excellent mechanical properties. The complex nano-laminate structure of this bio-composite material is characterized and related to its mechanical properties. Three levels of structural hierarchy are identified: macroscale mesolayers separating larger regions of tiled aragonite, microscale organization of 0.5 mum by 10 mum aragonite bricks; nanoscale mineral bridges passing through 30 nm layers of organic matrix separating individual aragonite tiles. Composition and growth mechanisms of this nanostructure were observed through close examination of laboratory-grown samples using scanning electron microscopy (SEM), Raman spectroscopy, and transmission electron microscopy (TEM). Glass slides and nacre pucks were implanted onto the growth surface of living abalone and removed periodically to observe trends in nacre deposition. Various deproteinization and demineralization experiments are used to explore the inorganic and organic components of the nacre's structure. The organic component of the shell is characterized by atomic force microscopy (AFM). The functionality of various biological materials is described and investigated. Two specific types of functionality are characterized, the ability of some materials to cut and puncture through sharp designs, and the ability for some materials to be used as attachment devices. Aspects of cutting materials employed by a broad range of animals were characterized and compared. In respect to the attachment mechanisms the foot of the abalone and the tree frog were

  19. The Dutch version of the Oxford Ankle and Foot Questionnaire for Children: Useful for evaluation of pediatric foot problems in groups.

    Science.gov (United States)

    Burger, Elise; Selles, Ruud; van Nieuwkasteele, Shelly; Bessems, Gert; Pollet, Virginie; Hovius, Steven; van Nieuwenhoven, Christianne

    2017-11-04

    The purpose of this study is to develop a Dutch version of the Oxford Ankle and Foot Questionnaire for Children (OxAFQ-c) to allow evaluation of pediatric foot care. The OxAFQ-c was translated into Dutch, according to the ISPOR-guidelines. Children with different foot and ankle complaints completed the OxAFQ-c at baseline, after two weeks, and after 4-6 months. Measurement properties were assessed in terms of reliability, responsiveness, and construct validity. Test-retest reliability showed moderate intraclass correlation coefficients. Bland-Altman plots showed wide limits of agreement. After 4-6 months, the group that experienced improvement also showed improved questionnaire outcomes, indicating responsiveness. Moderate correlation between the OxAFQ-c and the Kidscreen and foot-specific VAS-scores were observed, indicating moderate construct validity. The Dutch OxAFQ-c showed moderate to good measurement properties. However, because we observed limited sensitivity to changes and wide limits of agreement in individual patients, we think the questionnaire should only be used in groups. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  20. Diabetic foot syndrome as an interdisciplinary problem

    Directory of Open Access Journals (Sweden)

    Emilia Rymkiewicz

    2017-08-01

    Full Text Available Diabetes is a metabolic disease of the growing maturity. Diabetic foot syndrome is a chronic complications of diabetes. In neuropathic sensory disorders, ischemia of the lower limbs, and improper alignment metabolic control may occur in minor injuries around the foot, giving rise to a difficult healing ulcers. Even minor wounds rapidly infection by pathogenic bacteria, which significantly hinders their treatment. Health and life-saving solution in situations of persistent symptoms of infection is amputation of the lower limb. Doing so, however, does not solve the problem of diabetic and should be the final proceedings after having exhausted all possible treatments for diabetic foot syndrome.

  1. Development and validation of a questionnaire designed to measure foot-health status.

    Science.gov (United States)

    Bennett, P J; Patterson, C; Wearing, S; Baglioni, T

    1998-09-01

    The aim of this study was to apply the principles of content, criterion, and construct validation to a new questionnaire specifically designed to measure foot-health status. One hundred eleven subjects completed two different questionnaires designed to measure foot health (the new Foot Health Status Questionnaire and the previously validated Foot Function Index) and underwent a clinical examination in order to provide data for a second-order confirmatory factor analysis. Presented herein is a psychometrically evaluated questionnaire that contains 13 items covering foot pain, foot function, footwear, and general foot health. The tool demonstrates a high degree of content, criterion, and construct validity and test-retest reliability.

  2. Healing ulcers and preventing their recurrences in the diabetic foot

    Directory of Open Access Journals (Sweden)

    S Raja Sabapathy

    2016-01-01

    Full Text Available Fifteen percent of people with diabetes develop an ulcer in the course of their lifetime. Eighty-five percent of the major amputations in diabetes mellitus are preceded by an ulcer. Management of ulcers and preventing their recurrence is important for the quality of life of the individual and reducing the cost of care of treatment. The main causative factors of ulceration are neuropathy, vasculopathy and limited joint mobility. Altered bio-mechanics due to the deformities secondary to neuropathy and limited joint mobility leads to focal points of increased pressure, which compromises circulation leading to ulcers. Ulcer management must not only address the healing of ulcers but also should correct the altered bio-mechanics to reduce the focal pressure points and prevent recurrence. An analysis of 700 patients presenting with foot problems to the Diabetic Clinic of Ganga Hospital led to the stratification of these patients into four classes of incremental severity. Class 1 – the foot at risk, Class 2 – superficial ulcers without infection, Class 3 – the crippled foot and Class 4 – the critical foot. Almost 77.5% presented in either Class 3 or 4 with complicated foot ulcers requiring major reconstruction or amputation. Class 1 foot can be managed conservatively with foot care and appropriate foot wear. Class 2 in addition to measures for ulcer healing would need surgery to correct the altered bio-mechanics to prevent the recurrence. The procedures called surgical offloading would depend on the site of the ulcer and would need an in-depth clinical study of the foot. Class 3 would need major reconstructive procedures and Class 4 would need amputation since it may be life-threatening. As clinicians, our main efforts must be focused towards identifying patients in Class 1 and offer advice on foot care and Class 2 where appropriate surgical offloading procedure would help preserve the foot.

  3. The lives of Mary Foote: painter and Jungian.

    Science.gov (United States)

    Trousdell, Richard

    2016-11-01

    Mary Foote (1872-1968) was a successful early twentieth century American artist who suddenly closed her New York studio in 1926 to go to Zurich to study with Jung. There she joined his 'Interpretation of Visions' seminars (1930-1934), which she recorded and edited. This work won Jung's praise and his friendship, but all too often Foote was seen merely as a secretary or background figure. Deirdre Bair's biography of Jung suggested that Foote's life and work deserved fuller study, if only to rebalance our view of Jung's early women followers. This paper takes up that work to ask how Foote's early life and career led to her important work in preserving and describing Jung's earliest attempts to apply his theories to clinical practice. © 2016, The Society of Analytical Psychology.

  4. Validity and reliability of Thai version of the Foot and Ankle Outcome Score in patients with arthritis of the foot and ankle.

    Science.gov (United States)

    Angthong, Chayanin

    2016-12-01

    Although the Foot and Ankle Outcome Score (FAOS) is commonly used in several languages for a variety of foot disorders, it has not been validated specifically for foot and ankle arthritic conditions. The aims of the present study were to translate the original English FAOS into Thai and to evaluate the validity and reliability of the Thai version of the FAOS for the foot and ankle arthritic conditions. The original FAOS was translated into Thai using forward-backward translation. The Thai FAOS and validated Thai Short Form-36 (SF-36 ® ) questionnaires were distributed to 44 Thai patients suffering from arthritis of the foot and ankle to complete. For validation, Thai FAOS scores were correlated with SF-36 scores. Test-retest reliability and internal consistency were also analyzed in this study. The Thai FAOS score demonstrated sufficient correlation with SF-36 total score in Pain (Pearson's correlation coefficient (r)=0.45, p=0.002), Symptoms (r=0.45, p=0.002), Activities of Daily Living (ADL) (r=0.47, p=0.001), and Quality of Life (QOL) (r=0.38, p=0.011) subscales. The Sports and Recreational Activities (Sports & Rec) subscale did not correlate significantly with the SF-36 ® (r=0.20, p=0.20). Cronbach's alpha, a measure of internal consistency, for the five subscales was as follows: Pain, 0.94 (pvalidity for the evaluation of foot and ankle arthritis. Although reliability was satisfactory for the major subscale ADL, it was not sufficient for the minor subscales. Our findings suggest that it can be used as a disease-specific instrument to evaluate foot and ankle arthritis and can complement other reliable outcome surveys. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. Hydrothermal waves in evaporating sessile drops

    OpenAIRE

    Brutin, D.; Rigollet, F.; Niliot, C. Le

    2009-01-01

    Drop evaporation is a simple phenomena but still unclear concerning the mechanisms of evaporation. A common agreement of the scientific community based on experimental and numerical work evidences that most of the evaporation occurs at the triple line. However, the rate of evaporation is still empirically predicted due to the lack of knowledge on the convection cells which develop inside the drop under evaporation. The evaporation of sessile drop is more complicated than it appears due to the...

  6. Metronome rate and walking foot contact time in young adults.

    Science.gov (United States)

    Dickstein, Ruth; Plax, Michael

    2012-02-01

    It is assumed that when people walk guided by an audible constant rate, they match foot contact to the external pace. The purpose of this preliminary study was to test that assumption by examining the temporal relationship between audible signals generated by a metronome and foot contact time during gait. Ten healthy young women were tested in walking repetitions guided by metronome rates of 60, 110, and 150 beats/min. Metronome beats and foot contact times were collected in real time. The findings indicated that foot contact was not fully synchronized with the auditory signals; the shortest time interval between the metronome beat and foot contact time was at the prescribed rate of 60 beats/min., while the longest interval was at the rate of 150 beats/min. The correlation between left and right foot contact times was highest with the slowest rate and lowest with the fastest rate.

  7. Sex determination from hand and foot dimensions in a North Indian population.

    Science.gov (United States)

    Krishan, Kewal; Kanchan, Tanuj; Sharma, Abhilasha

    2011-03-01

    Hands and feet are often recovered from the site of natural as well as man-made disasters because of bomb blasts, train accidents, plane crashes, or mass homicides. This study is intended to establish standards for determination of sex from the dimensions of hands and feet in a North Indian population. The data for this study comprise 123 men and 123 women aged between 17 and 20 years from the "Rajput" population of Himachal Pradesh in North India. Four anthropometric measurements viz. hand length, hand breadth, foot length, and foot breadth have been taken on both sides of each subject following international anthropometric standards. The hand index (hand breadth/hand length × 100) and the foot index (foot breadth/foot length × 100) were calculated. Sectioning points and regression models are derived for the hand and foot dimensions and the derived indices. The hand and foot dimensions show a higher accuracy in sex determination by sectioning point analysis when compared to hand and foot index. Of the hand and the foot dimensions, hand breadth and foot breadth showed better accuracy in sex determination. Hand index and foot index remain poor sex discriminators in the study. © 2011 American Academy of Forensic Sciences.

  8. SU-F-BRA-03: Integrating Novel Electromagnetic Tracking Hollow Needle Assistance in Permanent Implant Brachytherapy Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Racine, E; Hautvast, G; Binnekamp, D [Philips Group Innovation - Biomedical Systems, Eindhoven (Netherlands); Beaulieu, L [Centre Hospitalier Univ de Quebec, Quebec, QC (Canada)

    2015-06-15

    Purpose: To report on the results of a complete permanent implant brachytherapy procedure assisted by an electromagnetic (EM) hollow needle possessing both 3D tracking and seed drop detection abilities. Methods: End-to-end in-phantom EM-assisted LDR procedures were conducted. The novel system consisted of an EM tracking apparatus (NDI Aurora V2, Planar Field Generator), a 3D US scanner (Philips CX50), a hollow needle prototype allowing 3D tracking and seed drop detection and a specially designed treatment planning software (Philips Healthcare). A tungsten-doped 30 cc spherical agarose prostate immersed in gelatin was used for the treatment. A cylindrical shape of 0.8 cc was carved along its diameter to mimic the urethra. An initial plan of 26 needles and 47 seeds was established with the system. The plan was delivered with the EM-tracked hollow needle, and individual seed drop locations were recorded on the fly. The phantom was subsequently imaged with a CT scanner from which seed positions and contour definitions were obtained. The DVHs were then independently recomputed and compared with those produced by the planning system, both before and after the treatment. Results: Of the 47 seeds, 45 (96%) were detected by the EM technology embedded in the hollow needle design. The executed plan (from CT analysis) differed from the initial plan by 2%, 14% and 8% respectively in terms of V100, D90 and V150 for the prostate, and by 8%, 7% and 10% respectively in terms of D5, V100 and V120 for the urethra. Conclusion: The average DVH deviations between initial and executed plans were within a 5% tolerance imposed for this proof-of-concept assessment. This relatively good concordance demonstrates the feasibility and potential benefits of combining EM tracking and seed drop detection for real-time dosimetry validation and assistance in permanent implant brachytherapy procedures. This project has been entirely funded by Philips Healthcare.

  9. Diabetic foot workshop: Improving technical and educational skills for nurses.

    Science.gov (United States)

    Aalaa, Maryam; Sanjari, Mahnaz; Shahbazi, Samimeh; Shayeganmehr, Zahra; Abooeirad, Maryam; Amini, Mohammad Reza; Adibi, Hossien; Mehrdad, Neda

    2017-01-01

    Diabetes mellitus as one of the most common metabolic disorders has some complications, one of the main ones is diabetic foot (DF). Appropriate care and education prevents 85% of diabetic foot amputations. An ideal management to prevent and treat diabetic foot necessitates a close collaboration between the health team members and the diabetic patient. Therefore, improving nurses' knowledge about DF care and advancement in the quality of care provided by the nurses could significantly improve diabetic foot prevention and management. Therefore, the aim of DF workshop was to improve technical and educational skills of the nurses to prevent and manage diabetic foot. Considering the vital role of the nurses in providing DF care, EMRI decided to conduct Diabetic foot workshop for them. The following five steps were designed for the 14 coordinating sessions in the workshop: Goals definition, deciding about attendees, location selection, creating agenda, and developing a follow-up plan. "Diabetic Foot Workshop for Nurses" provides appropriate training to DF nurses at the national level; and combining theory and practice in this workshop not only increases nurses' knowledge, but also improves their skills in the field of the diabetic foot. Providing education and care to patients by DF nurse specialists instead of general nurses could be an important output of this workshop, which may lead to DF prevention and amputation decrease in the long term.

  10. DESIGN OPTIMIZATION OF A FOOT VALVE BY USING ANSYS®

    Directory of Open Access Journals (Sweden)

    Serdar KARAOĞLU

    2008-02-01

    Full Text Available In this study, main components of a foot valve, being produced by casting, were optimized for minimum weight. The study was focused on the minimization of casting costs by reducing the volumes of two main parts of the foot valve. ANSYS® finite elements package was used in the study. In the optimization stage, parametrical dimensions were determined according to manufacturer's design criteria and related standards. Final design of the foot valve was completed by using the calculated values of optimum dimensions of the main components. Design optimization procedure gave about 8.5% of weight reductions in the main foot valve components.

  11. Foot strike patterns and collision forces in habitually barefoot versus shod runners.

    Science.gov (United States)

    Lieberman, Daniel E; Venkadesan, Madhusudhan; Werbel, William A; Daoud, Adam I; D'Andrea, Susan; Davis, Irene S; Mang'eni, Robert Ojiambo; Pitsiladis, Yannis

    2010-01-28

    Humans have engaged in endurance running for millions of years, but the modern running shoe was not invented until the 1970s. For most of human evolutionary history, runners were either barefoot or wore minimal footwear such as sandals or moccasins with smaller heels and little cushioning relative to modern running shoes. We wondered how runners coped with the impact caused by the foot colliding with the ground before the invention of the modern shoe. Here we show that habitually barefoot endurance runners often land on the fore-foot (fore-foot strike) before bringing down the heel, but they sometimes land with a flat foot (mid-foot strike) or, less often, on the heel (rear-foot strike). In contrast, habitually shod runners mostly rear-foot strike, facilitated by the elevated and cushioned heel of the modern running shoe. Kinematic and kinetic analyses show that even on hard surfaces, barefoot runners who fore-foot strike generate smaller collision forces than shod rear-foot strikers. This difference results primarily from a more plantarflexed foot at landing and more ankle compliance during impact, decreasing the effective mass of the body that collides with the ground. Fore-foot- and mid-foot-strike gaits were probably more common when humans ran barefoot or in minimal shoes, and may protect the feet and lower limbs from some of the impact-related injuries now experienced by a high percentage of runners.

  12. Parametric resonance in acoustically levitated water drops

    International Nuclear Information System (INIS)

    Shen, C.L.; Xie, W.J.; Wei, B.

    2010-01-01

    Liquid drops can be suspended in air with acoustic levitation method. When the sound pressure is periodically modulated, the levitated drop is usually forced into an axisymmetric oscillation. However, a transition from axisymmetric oscillation into sectorial oscillation occurs when the modulation frequency approaches some specific values. The frequency of the sectorial oscillation is almost exactly half of the modulation frequency. It is demonstrated that this transition is induced by the parametric resonance of levitated drop. The natural frequency of sectorial oscillation is found to decrease with the increase of drop distortion extent.

  13. Parametric resonance in acoustically levitated water drops

    Energy Technology Data Exchange (ETDEWEB)

    Shen, C.L.; Xie, W.J. [Department of Applied Physics, Northwestern Polytechnical University, Xi' an 710072 (China); Wei, B., E-mail: bbwei@nwpu.edu.c [Department of Applied Physics, Northwestern Polytechnical University, Xi' an 710072 (China)

    2010-05-10

    Liquid drops can be suspended in air with acoustic levitation method. When the sound pressure is periodically modulated, the levitated drop is usually forced into an axisymmetric oscillation. However, a transition from axisymmetric oscillation into sectorial oscillation occurs when the modulation frequency approaches some specific values. The frequency of the sectorial oscillation is almost exactly half of the modulation frequency. It is demonstrated that this transition is induced by the parametric resonance of levitated drop. The natural frequency of sectorial oscillation is found to decrease with the increase of drop distortion extent.

  14. [Anlysis of foot biomechanics characteristic in 303 patients with type 2 diabetes mellitus].

    Science.gov (United States)

    Li, Wen-Xia; Cao, Ying; Zou, Meng-Chen; Huang, Ying; Hu, Ping; Luo, Xiang-Rong; Jiang, Ya; Xue, Yao-Ming; Gao, Fang

    2016-10-20

    To investigate foot biomechanics characteristic of patients with type 2 diabetes mellitus. This study was conducted among 303 patients with type 2 diabetes. The whole foot was divided into 10 regions, namely the first toe (T1); the second to fifth toes (T2-5); the first, second, third, fourth, and fifth metatarsals (M1, M2, M3, M4, and M5, respectively); midfoot (MF), and the heel medial (HM). Foot arch index, foot angle and maximum peak pressure (MPP) of the 10 regions were measured using a Footscan gait system. The maximum peak pressure of 10 regions decreased in the order of M3>M2>HM>M4>HL>M1>M5>T1>ML>T2-5 for the left foot, and in the order of M3>M2>HM>M4>HL>M1>M5>T1>ML>T2-5 for the right foot. The MPP in M1 region was higher in the right than in the left foot (Ppatients. Foot flat phase was extended and forefoot push-off phase shortened in stance phase in the patients. Compared with the right foot, the left foot showed a significantly increased foot arch index and increased low and high arch rates with a decreased normal arch rate. Total plantar pressure was higher in of the left high arch foot than in normal arch foot. The foot angle was significantly larger on the right than on the left. The bilateral total plantar pressures were significantly greater in male patients (Ppatients have obvious alterations in foot biomechanics with abnormalities of the plantar pressure, and the percentage of high-risk foot increases in overweight and obese patients, suggesting the need of body weight control in these patients when administering offloading treatment for prevention of diabetic foot ulcer.

  15. NUMERICAL MODELLING OF CHICKEN-FOOT FOUNDATION

    Directory of Open Access Journals (Sweden)

    Vipman Tandjiria

    1999-01-01

    Full Text Available This paper presents an analysis of the chicken-foot foundation using the finite element method. The foundation is considered as a reinforced concrete slab resting on a number of reinforced concrete pipes filled with and surrounded by in-situ soil. The soil and the pipes were modelled by isoparametric solid elements while the slab was modelled by isoparametric thick-plate elements. The study was intended to illustrate the basic mechanism of the chicken-foot foundation. Three cases have been considered for the parametric studies. The parameters investigated are thickness of slab, length of pipes and spacing between pipes. It is shown that such a foundation improves the behaviour of the raft foundation. It is also found that all the parameters used in the parametric studies influence the behaviour of the chicken-foot foundation.

  16. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  17. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  18. Nonplantigrade Foot Posture: A Constraint on Dinosaur Body Size

    OpenAIRE

    Kubo, Tai; Kubo, Mugino O.

    2016-01-01

    Dinosaurs had functionally digitigrade or sub-unguligrade foot postures. With their immediate ancestors, dinosaurs were the only terrestrial nonplantigrades during the Mesozoic. Extant terrestrial mammals have different optimal body sizes according to their foot posture (plantigrade, digitigrade, and unguligrade), yet the relationship of nonplantigrade foot posture with dinosaur body size has never been investigated, even though the body size of dinosaurs has been studied intensively. Accordi...

  19. Deformed liquid marbles: Freezing drop oscillations with powders

    KAUST Repository

    Marston, Jeremy; Zhu, Y.; Vakarelski, Ivan Uriev; Thoroddsen, Sigurdur T

    2012-01-01

    In this work we show that when a liquid drop impacts onto a fine-grained hydrophobic powder, the final form of the drop can be very different from the spherical form with which it impacts. In all cases, the drop rebounds due to the hydrophobic nature of the powder. However, we find that above a critical impact speed, the drop undergoes a permanent deformation to a highly non-spherical shape with a near-complete coverage of powder, which then freezes the drop oscillations during rebound. © 2012 Elsevier B.V.

  20. Deformed liquid marbles: Freezing drop oscillations with powders

    KAUST Repository

    Marston, Jeremy

    2012-09-01

    In this work we show that when a liquid drop impacts onto a fine-grained hydrophobic powder, the final form of the drop can be very different from the spherical form with which it impacts. In all cases, the drop rebounds due to the hydrophobic nature of the powder. However, we find that above a critical impact speed, the drop undergoes a permanent deformation to a highly non-spherical shape with a near-complete coverage of powder, which then freezes the drop oscillations during rebound. © 2012 Elsevier B.V.

  1. Nociception at the diabetic foot, an uncharted territory

    Science.gov (United States)

    Chantelau, Ernst A

    2015-01-01

    The diabetic foot is characterised by painless foot ulceration and/or arthropathy; it is a typical complication of painless diabetic neuropathy. Neuropathy depletes the foot skin of intraepidermal nerve fibre endings of the afferent A-delta and C-fibres, which are mostly nociceptors and excitable by noxious stimuli only. However, some of them are cold or warm receptors whose functions in diabetic neuropathy have frequently been reported. Hence, it is well established by quantitative sensory testing that thermal detection thresholds at the foot skin increase during the course of painless diabetic neuropathy. Pain perception (nociception), by contrast, has rarely been studied. Recent pilot studies of pinprick pain at plantar digital skinfolds showed that the perception threshold was always above the upper limit of measurement of 512 mN (equivalent to 51.2 g) at the diabetic foot. However, deep pressure pain perception threshold at musculus abductor hallucis was beyond 1400 kPa (equivalent to 14 kg; limit of measurement) only in every fifth case. These discrepancies of pain perception between forefoot and hindfoot, and between skin and muscle, demand further study. Measuring nociception at the feet in diabetes opens promising clinical perspectives. A critical nociception threshold may be quantified (probably corresponding to a critical number of intraepidermal nerve fibre endings), beyond which the individual risk of a diabetic foot rises appreciably. Staging of diabetic neuropathy according to nociception thresholds at the feet is highly desirable as guidance to an individualised injury prevention strategy. PMID:25897350

  2. Leonardo da Vinci's foot: historical evidence of concept.

    Science.gov (United States)

    Jastifer, James R; Toledo-Pereyra, Luis H

    2012-10-01

    Leonardo da Vinci (1452-1519), world-renowned Italian renaissance master, is known for his contributions to, and broad interests in science and art. The objective of this work is to demonstrate the extent of his science by applying the use of his concepts to current models of foot and ankle mechanics. The art and science of Leonardo Da Vinci were extensively analyzed by reviewing his original drawings and hand written notebooks as well as their English translation. Current medical journals including the topics of foot, ankle, and biomechanics were reviewed for modern evidence and application of his concepts. The library of Michigan State University and the electronic library of the Royal Library at Windsor Castle were extensively utilized. From the depths of Santa Maria Nuova Hospital in Florence and Santo Spirito Hospital in Rome, through his commentary and anatomical drawings of around 30 cadaver dissections he performed, Leonardo da Vinci expressed his concept of foot and ankle anatomy and mechanics. He laid forth concepts, which vary little from current theories including those of proportion, statics and joint stability, sesamoid biomechanics, and structural support of the foot. Leonardo da Vinci, by combining an interest in anatomy and a gift of genius and artistic ability laid a foundation of foot and ankle anatomy and mechanics that have been applied in modern clinical sciences. Leonardo in this way made important contributions to the practice of foot and ankle orthopedics.

  3. Primary prevention of peri-implantitis: Managing peri-implant mucositis

    OpenAIRE

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; LAMBERT, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni; Schwarz, Frank; Serino, Giovanni

    2015-01-01

    Abstract AIMS: Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considere...

  4. Imaging of Charcot foot; Bildgebung des Charcot-Fusses

    Energy Technology Data Exchange (ETDEWEB)

    Erlemann, Rainer; Schmitz, Annette [Helios Klinikum Duisburg, Helios St. Johannes Klinik, Duisburg (Germany). Inst. fuer Radiologie

    2014-03-15

    The onset of a Charcot foot ist a feared complication of a long lasting diabetes mellitus. A peripheral neuropathy and continuous weight bearing of the foot subsequent to repeated traumas depict the conditions. There exist three types of a Charcot foot, an atrophic, a hypertophic and a mixed type. In early stages a differentiation from osteoarthritis is difficult. Subluxation or luxation within the Lisfranc's joint is typical. The joints of the foot could rapidly and extensively be destroyed or may present the morphology of a 'superosteoarthritis'. Often, soft tissue infections or osteomyelitis evolve from ulcers of the skin as entry points. Diagnosis of osteomyelitis necessitate MR imaging as plain radiography offers only low sensitivity for detection of an osteomyelitis. The existence of periosteal reactions is not a proof for osteomyelitis. Bone marrow edema and soft tissue edema also appear in a non infected Charcot foot. The range of soft tissue infections goes from cellulitis over phlegmon to abscesses. The ghost sign is the most suitable diagnostic criterion for osteomyelitis. In addition, the penumbra sign or the existence of a sinus tract between a skin ulcer and the affected bone may be helpful. (orig.)

  5. Foot Structure in Boys with Down Syndrome

    Directory of Open Access Journals (Sweden)

    Ewa Puszczałowska-Lizis

    2017-01-01

    Full Text Available Introduction and Aim. Down syndrome (DS is associated with numerous developmental abnormalities, some of which cause dysfunctions of the posture and the locomotor system. The analysis of selected features of the foot structure in boys with DS versus their peers without developmental disorders is done. Materials and Methods. The podoscopic examination was performed on 30 boys with DS aged 14-15 years. A control group consisted of 30 age- and gender-matched peers without DS. Results. The feet of boys with DS are flatter compared to their healthy peers. The hallux valgus angle is not the most important feature differentiating the shape of the foot in the boys with DS and their healthy peers. In terms of the V toe setting, healthy boys had poorer results. Conclusions. Specialized therapeutic treatment in individuals with DS should involve exercises to increase the muscle strength around the foot joints, enhancing the stabilization in the joints and proprioception. Introducing orthotics and proper footwear is also important. It is also necessary to monitor the state of the foot in order to modify undertaken therapies.

  6. Osteogenesis and Morphology of the Peri-Implant Bone Facing Dental Implants

    Directory of Open Access Journals (Sweden)

    Marco Franchi

    2004-01-01

    Full Text Available This study investigated the influence of different implant surfaces on peri-implant osteogenesis and implant face morphology of peri-implant tissues during the early (2 weeks and complete healing period (3 months. Thirty endosseous titanium implants (conic screws with differently treated surfaces (smooth titanium = SS, titanium plasma sprayed = TPS, sand-blasted zirconium oxide = Zr-SLA were implanted in femur and tibiae diaphyses of two mongrel sheep. Histological sections of the implants and surrounding tissues obtained by sawing and grinding techniques were observed under light microscopy (LM. The peri-implant tissues of other samples were mechanically detached from the corresponding implants to be processed for SEM observation. Two weeks after implantation, we observed osteogenesis (new bone trabeculae around all implant surfaces only where a gap was present at the host bone-metal interface. No evident bone deposition was detectable where threads of the screws were in direct contact with the compact host bone. Distance osteogenesis predominated in SS implants, while around rough surfaces (TPS and Zr-SLA, both distance and contact osteogenesis were present. At SEM analysis 2 weeks after implantation, the implant face of SS peri-implant tissue showed few, thin, newly formed, bone trabeculae immersed in large, loose, marrow tissue with blood vessels. Around the TPS screws, the implant face of the peri-implant tissue was rather irregular because of the rougher metal surface. Zr-SLA screws showed more numerous, newly formed bone trabeculae crossing marrow spaces and also needle-like crystals in bone nodules indicating an active mineralising process. After 3 months, all the screws appeared osseointegrated, being almost completely covered by a compact, mature, newly formed bone. However, some marrow spaces rich in blood vessels and undifferentiated cells were in contact with the metal surface. By SEM analysis, the implant face of the peri-implant

  7. Improving diabetic foot care in a nurse-managed safety-net clinic.

    Science.gov (United States)

    Peterson, Joann M; Virden, Mary D

    2013-05-01

    This article is a description of the development and implementation of a Comprehensive Diabetic Foot Care Program and assessment tool in an academically affiliated nurse-managed, multidisciplinary, safety-net clinic. The assessment tool parallels parameters identified in the Task Force Foot Care Interest Group of the American Diabetes Association's report published in 2008, "Comprehensive Foot Examination and Risk Assessment." Review of literature, Silver City Health Center's (SCHC) 2009 Annual Report, retrospective chart review. Since the full implementation of SCHC's Comprehensive Diabetic Foot Care Program, there have been no hospitalizations of clinic patients for foot-related complications. The development of the Comprehensive Diabetic Foot Assessment tool and the implementation of the Comprehensive Diabetic Foot Care Program have resulted in positive outcomes for the patients in a nurse-managed safety-net clinic. This article demonstrates that quality healthcare services can successfully be developed and implemented in a safety-net clinic setting. ©2012 The Author(s) Journal compilation ©2012 American Association of Nurse Practitioners.

  8. Levitation of a drop over a film flow

    Science.gov (United States)

    Sreenivas, K. R.; de, P. K.; Arakeri, Jaywant H.

    1999-02-01

    A vertical jet of water impinging on a horizontal surface produces a radial film flow followed by a circular hydraulic jump. We report a phenomenon where fairly large (1 ml) drops of liquid levitate just upstream of the jump on a thin air layer between the drop and the film flow. We explain the phenomenon using lubrication theory. Bearing action both in the air film and the water film seems to be necessary to support large drops. Horizontal support is given to the drop by the hydraulic jump. A variety of drop shapes is observed depending on the volume of the drop and liquid properties. We show that interaction of the forces due to gravity, surface tension, viscosity and inertia produces these various shapes.

  9. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    Science.gov (United States)

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when

  10. An epidemiologic study of flat foot in Iran

    Directory of Open Access Journals (Sweden)

    Alamy B

    1997-07-01

    Full Text Available Among 880 studied feet of 7-14 years old children 6.9% suffered mild and severe flat foot. 53.8% of the affected children were symptomatic. As 40.1% of the general population experiences symptoms, in a small proportion of affected persons, symptoms are due to flat foot. The prevalence of symptoms rises with increasing severity of the disorder. In this article, reviewing general aspects of flat food, prevalence and other epidemiological aspects of flat foot for the first time in Iran have been presented

  11. Evaluation of foot static disturbances in patients with rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Anna Kuryliszyn-Moskal

    2017-04-01

    Full Text Available Objectives : Rheumatic diseases such as osteoarthritis and rheumatoid arthritis constitute the most frequent pathological states leading to the development of foot deformities, which reduce quality of life and cause disability. The aim of the present study was to compare the results of plantoconturographic examinations, obtained by means of a computer podoscope, in osteoarthritis and rheumatoid arthritis patients. Special attention was paid to the differences in the values of each parameter determining the level of foot function. Material and methods : The study was performed in 94 female patients divided into two groups according to the type of disease. There were 54 patients with rheumatoid arthritis and 40 with osteoarthritis. The control group consisted of 34 healthy women. The plantographic assessment of static foot structure was carried out by means of a device for computer-aided foot examination. Results : A fallen transverse arch of the right foot was statistically much more frequent in the rheumatoid arthritis patients than in osteoarthritis patients or the control group (p < 0.005 and p < 0.05, respectively. Significant differences in the values of the Wejsflog index were observed in the case of left foot between rheumatoid arthritis patients and the control group (p < 0.05. Similarly, there were statistically significant differences in the values of the hallux valgus angle ( for the right foot between rheumatoid arthritis and osteoarthritis patients or control group (in both cases p < 0.05. Conclusions : Rheumatic diseases predispose patients to disturbances of static foot function. The obtained results highlight the importance of diagnosing foot static disturbances in the prevention of destructive changes affecting the functioning of osteoarthritis and rheumatoid arthritis patients.

  12. Foot Placement Modification for a Biped Humanoid Robot with Narrow Feet

    Directory of Open Access Journals (Sweden)

    Kenji Hashimoto

    2014-01-01

    Full Text Available This paper describes a walking stabilization control for a biped humanoid robot with narrow feet. Most humanoid robots have larger feet than human beings to maintain their stability during walking. If robot’s feet are as narrow as humans, it is difficult to realize a stable walk by using conventional stabilization controls. The proposed control modifies a foot placement according to the robot's attitude angle. If a robot tends to fall down, a foot angle is modified about the roll axis so that a swing foot contacts the ground horizontally. And a foot-landing point is also changed laterally to inhibit the robot from falling to the outside. To reduce a foot-landing impact, a virtual compliance control is applied to the vertical axis and the roll and pitch axes of the foot. Verification of the proposed method is conducted through experiments with a biped humanoid robot WABIAN-2R. WABIAN-2R realized a knee-bended walking with 30 mm breadth feet. Moreover, WABIAN-2R mounted on a human-like foot mechanism mimicking a human's foot arch structure realized a stable walking with the knee-stretched, heel-contact, and toe-off motion.

  13. Development of a foot impact scale for rheumatoid arthritis.

    Science.gov (United States)

    Helliwell, Philip; Reay, Naomi; Gilworth, Gill; Redmond, Anthony; Slade, Anita; Tennant, Alan; Woodburn, James

    2005-06-15

    To develop a new foot impact scale to assess foot status in rheumatoid arthritis (RA) using established qualitative methodology and the latest item response techniques (Rasch analysis). Foot problems in RA were explored by conducting qualitative interviews that were then used to generate items for a new foot impact scale. Further validation was undertaken following postal surveys and Rasch analysis. Analysis of the first postal survey (n = 192 responses) produced a 63-item binary response, 4-subscale instrument. The 4 subscales covered the domains impairment, activities, participation, and footwear. Following test-retest postal surveys and additional analysis, the instrument was reduced to a 2 subscale, 51-item questionnaire covering the domains of impairments/shoes and activities/participation. Initial results of these subscales indicate good psychometric properties, external validity, and test-retest reliability. A foot impact scale to assess the impact of RA and to measure the effect of interventions has been developed. The 2 scales comprising the instrument demonstrate good psychometric properties.

  14. Attitude and knowledge about foot health: a spanish view

    Directory of Open Access Journals (Sweden)

    Daniel López-López

    Full Text Available ABSTRACT Objective: to explore attitudes towards patients' self-reported data about foot health-related beliefs from a behavioural and attitudinal perspective. Methods: a sample of 282 participants of a mean age of 39.46 ± 16.026 came to a health centre where self-reported demographic, clinical characteristics and beliefs relating to foot health data were registered, informants' completed all the stages of the research process. Results: the results of the analysis revealed an 8-factor factorial structure based on (1 podiatric behaviours, (2 the intention to carry out protective behaviour, (3 attitudinal beliefs, (4 normative beliefs, (5 needs, (6 apathy, (7 self-care, and (8 the general perception of foot health. They all explained 62.78% of the variance, and were considered as independent variables in a regression analysis to determine which provided the best explanations for the importance attributed to foot health. Conclusions: the participants in the study revealed a positive attitude in relation to foot health care and responsible behaviour.

  15. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Foot Type Biomechanics Part 2: are structure and anthropometrics related to function?

    Science.gov (United States)

    Mootanah, Rajshree; Song, Jinsup; Lenhoff, Mark W; Hafer, Jocelyn F; Backus, Sherry I; Gagnon, David; Deland, Jonathan T; Hillstrom, Howard J

    2013-03-01

    Many foot pathologies are associated with specific foot types. If foot structure and function are related, measurement of either could assist with differential diagnosis of pedal pathologies. Biomechanical measures of foot structure and function are related in asymptomatic healthy individuals. Sixty-one healthy subjects' left feet were stratified into cavus (n=12), rectus (n=27) and planus (n=22) foot types. Foot structure was assessed by malleolar valgus index, arch height index, and arch height flexibility. Anthropometrics (height and weight), age, and walking speed were measured. Foot function was assessed by center of pressure excursion index, peak plantar pressure, maximum force, and gait pattern parameters. Foot structure and anthropometric variables were entered into stepwise linear regression models to identify predictors of function. Measures of foot structure and anthropometrics explained 10-37% of the model variance (adjusted R(2)) for gait pattern parameters. When walking speed was included, the adjusted R(2) increased to 45-77% but foot structure was no longer a factor. Foot structure and anthropometrics predicted 7-47% of the model variance for plantar pressure and 16-64% for maximum force parameters. All multivariate models were significant (pFoot structure and function are related in asymptomatic healthy individuals. The structural parameters employed are basic measurements that do not require ionizing radiation and could be used in a clinical setting. Further research is needed to identify additional predictive parameters (plantar soft tissue characteristics, skeletal alignment, and neuromuscular control) and to include individuals with pathology. Copyright © 2012. Published by Elsevier B.V.

  17. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  18. The Charcot Foot in Diabetes

    Science.gov (United States)

    Frykberg, Robert G.; Armstrong, David G.; Boulton, Andrew J.M.; Edmonds, Michael; Van, Georges Ha; Hartemann, Agnes; Game, Frances; Jeffcoate, William; Jirkovska, Alexandra; Jude, Edward; Morbach, Stephan; Morrison, William B.; Pinzur, Michael; Pitocco, Dario; Sanders, Lee; Wukich, Dane K.; Uccioli, Luigi

    2011-01-01

    The diabetic Charcot foot syndrome is a serious and potentially limb-threatening lower-extremity complication of diabetes. First described in 1883, this enigmatic condition continues to challenge even the most experienced practitioners. Now considered an inflammatory syndrome, the diabetic Charcot foot is characterized by varying degrees of bone and joint disorganization secondary to underlying neuropathy, trauma, and perturbations of bone metabolism. An international task force of experts was convened by the American Diabetes Association and the American Podiatric Medical Association in January 2011 to summarize available evidence on the pathophysiology, natural history, presentations, and treatment recommendations for this entity. PMID:21868781

  19. Diabetic gangrene of the foot

    International Nuclear Information System (INIS)

    Tanaka, Junji; Hoshi, Makoto; Shinozaki, Tatsuyo; Kimura, Masakata; Ichinohe, Hitomoto.

    1983-01-01

    A case of severe diabetic gangrene was reported. Angiography showed no evidence of ischemic changes in the foot, except for mild atherosclerosis in the femoral and popliteal arteries. Tc-99m labelled macroagglugated albumine (MAA) was injected transcatheterally into the abdominal aorta to see the blood perfusion of the lower extremities, which showed increased blood flow of the foot as well as the presence of micro arteriovenous shuntings shown by the appearance of both lungs. Damages of the microcirculation are thought to have much influences on the formation of diabetic gangrene. Histopathological findings supported above. (author)

  20. VACUUM ASSISTED CLOSURE IN DIABETIC FOOT MANAGEMENT

    OpenAIRE

    Moganakannan; `Prema; Arun Sundara Rajan

    2014-01-01

    Comparision of vacuum assisted closure vs conventional dressing in management of diabetic foot patients. 30 patients were taken in that 15 underwent vacuum therapy and remaining 15 underwent conventional dressing.They were analysed by the development of granulation tissue and wound healing.The study showed Vac therapy is the best modality for management of diabetic foot patients.

  1. Treatment for Common Running/Walking Foot Injuries

    Science.gov (United States)

    McDaniel, Larry W.; Haar, Calin; Ihlers, Matt; Jackson, Allen; Gaudet, Laura

    2009-01-01

    Whether you are a weekend warrior or a serious athlete, most runners fear the possibility of being injured. For those who are physically active or stand on their feet all day, healthy feet are important Highly conditioned runners spend many hours performing foot maintenance to prevent unnecessary injuries. Some of the common foot injuries are:…

  2. Analysis of risk factors for neuropathic foot ulceration in diabetes mellitus.

    Science.gov (United States)

    Bennett, P J; Stocks, A E; Whittam, D J

    1996-03-01

    Diabetes mellitus affects about one in 25 Australians. Neuropathic foot ulceration is a frequent complication in persons with diabetes. This study evaluates the importance of different risk factors for the development of this condition. The role of nonenzymatic glycosylation and pressure beneath the sole of the foot in the pathogenesis of neuropathic foot ulcers was investigated. Twenty-seven subjects with diabetes with a recent history of neuropathic foot ulceration were matched by age and sex with a group of 50 control subjects without neuropathy or history of foot ulceration. The degree of nonenzymatic glycosylation was assessed by analyzing the average level of glycosylated hemoglobin in the 3 years prior to the development of the foot ulcer and a goniometer assessment of peripheral joint (hand and ankle) flexibility. Dynamic pressure of the plantar aspect of the foot was recorded using a Musgrave Footprint System pedobarograph during a normal gait cycle. There was no significant difference in age, sex, body mass index, and duration or type of diabetes between the ulcer and control groups. The pressure of the plantar aspect of the foot was significantly elevated (p < 0.01). Ankle joint flexibility was reduced (p < 0.01) in cases with neuropathic foot ulceration compared with the control group. There was a trend toward elevation of glycosylated hemoglobin (HbA1c fraction) or HbA1c in the ulcer group (p = 0.06). The results suggested that nonenzymatic glycosylation occurs at a more significant level in patients with diabetes with a history of neuropathic foot ulceration.

  3. Quality and Toxicity Assessments of Foot and Mouth Disease Virus ...

    African Journals Online (AJOL)

    The quality and toxicity assessment of foot and mouth disease virus vaccine was carried out in inoculated guinea pigs. ... could be used for the control and prevention of foot and mouth disease in Nigerian livestock. Keyword: Foot and Mouth Disease ... 2 blended with Incomplete. Seepic Adjuvant (ISA) montanide 206, which.

  4. The prevalence of foot ulceration in patients with rheumatoid arthritis.

    Science.gov (United States)

    Firth, Jill; Hale, Claire; Helliwell, Philip; Hill, Jackie; Nelson, E Andrea

    2008-02-15

    To establish the prevalence of foot ulceration in patients with rheumatoid arthritis (RA) in secondary care. A postal survey of all patients with RA (n = 1,130) under the care of rheumatologists in Bradford, West Yorkshire, UK was performed. The prevalence data were validated through clinical examination, case-note review, and contact with health professionals. The false-negative rate was investigated in a subsample of patients (n = 70) who denied any history of ulceration. The postal survey achieved a 78% response rate. Following validation, the point prevalence of foot ulceration was 3.39% and the overall prevalence was 9.73%. The false-positive rate was initially high at 21.21%, but use of diagrammatic questionnaire data to exclude leg ulceration reduced the rate to 10.76%. The false-negative rate was 11.76%. The most common sites for ulceration were the dorsal aspect of hammer toes, the metatarsal heads, and the metatarsophalangeal joint in patients with hallux abducto valgus, with 33% of patients reporting multiple sites of ulceration. Patients with open-foot and healed-foot ulceration had significantly longer RA disease duration, reported significantly greater use of special footwear, and had a higher prevalence of foot surgery than ulcer-free patients. Foot ulceration affects a significant proportion of patients with RA. Further work is needed to establish risk factors for foot ulceration in RA and to target foot health provision more effectively.

  5. Immediate versus early non-occlusal loading of dental implants placed flapless in partially edentulous patients: a 3-year randomized clinical trial.

    Science.gov (United States)

    Merli, Mauro; Moscatelli, Marco; Mariotti, Giorgia; Piemontese, Matteo; Nieri, Michele

    2012-02-01

    To compare immediate versus early non-occlusal loading of dental implants placed flapless in a 3-year, parallel group, randomized clinical trial. The study was conducted in a private dental clinic between July 2005 and July 2010. Patients 18 years or older were randomized to receive implants for fixed partial dentures in cases of partial edentulism. The test group was represented by immediate non-occlusal implant loading, whereas the control group was represented by early non-occlusal implant loading. The outcome variables were implant failure, complications and radiographic bone level at implant sites 3 years after loading, measured from the implant-abutment junction to the most coronal point of bone-to-implant contact. Randomization was computer-generated with allocation concealment by opaque sequentially numbered sealed envelopes, and the measurer was blinded to group assignment. Sixty patients were randomized: 30 to the immediately loaded group and 30 to the early loaded group. Four patients dropped out; however, the data of all patients were included in the analysis. No implant failure occurred. Two complications occurred in the control group and one in the test group. The mean bone level at 3 years was 1.91 mm for test group and 1.59 mm for control group. The adjusted difference in bone level was 0.26 mm (CI 95% -0.08 to 0.59, p = 0.1232). The null hypothesis of no difference in failure rates, complications and bone level between implants that were loaded immediately or early at 3 years cannot be rejected in this randomized clinical trial. © 2011 John Wiley & Sons A/S.

  6. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search......-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  7. The Assessment of Social Support and Self-Care Requisites for Preventing Diabetic Foot Ulcer in Diabetic Foot Patients

    Directory of Open Access Journals (Sweden)

    Mohammad Taher

    2016-03-01

    Full Text Available Background and Objectives: Diabetic foot as one of the most common complications of diabetes is involved in more than %25 of diabetic patients’ lives, and if not treated properly can lead to amputation up to %20. The lack of self-care is the underlying cause of mortality, morbidity and chronic complications of diabetes. Identification and rectifying of diabetic foot care needs of patients can additionally reduce readmission; also, %85 of diabetic foot problems can be prevented. Materials and Methods: In this descriptive study, 130patients with diabetic foot from Shahid Modarres hospital were selected using census method. Data in forms of demographic questionnaire, self-care requisites assessment tool for preventing diabetic foot ulcer, and Social Support Behavior Scale were completed by patients and then were collected. Data were analyzed by SPSS version 16. Results: In this study, a significant relationship was found between self-care and social support (P<0.05. This means that people with better social support reported better self-care than those with weaker social support. A significant relationship in level of education and monthly income with self-care was seen, as well as in level of education, monthly income and marital status with social support (P<0.001. Conclusions: The results showed that social support can be considered as an effective factor in individual self-care behaviors, and with regard to this factor in educational, treatment and care programs of patients, can improve their self-care, in addition to decreasing economic costs, and improve their qualities of lives as well.

  8. Imaging of common breast implants and implant-related complications: A pictorial essay.

    Science.gov (United States)

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  9. Drop Test Results of CRDM under Seismic Loads

    International Nuclear Information System (INIS)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Kim, Gyeong-Ho; Sun, Jong-Oh; Huh, Hyung

    2016-01-01

    This paper describes the test results to demonstrate the drop performance of CRDM under seismic loads. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the drop performance under seismic loads such as operating basis earthquake (OBE) and safe shutdown earthquake (SSE). Especially, the CAR drop times are important data for the safety analysis. confirm the drop performance under seismic loads. The delay of drop time at Rig no. 2 due to seismic loads is greater than that at Rig no. 3. The total pure drop times under seismic loads are estimated as 1.169 and 1.855, respectively

  10. Drop Test Results of CRDM under Seismic Loads

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Kim, Gyeong-Ho; Sun, Jong-Oh; Huh, Hyung [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    This paper describes the test results to demonstrate the drop performance of CRDM under seismic loads. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the drop performance under seismic loads such as operating basis earthquake (OBE) and safe shutdown earthquake (SSE). Especially, the CAR drop times are important data for the safety analysis. confirm the drop performance under seismic loads. The delay of drop time at Rig no. 2 due to seismic loads is greater than that at Rig no. 3. The total pure drop times under seismic loads are estimated as 1.169 and 1.855, respectively.

  11. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  12. Impact of granular drops

    KAUST Repository

    Marston, J. O.

    2013-07-15

    We investigate the spreading and splashing of granular drops during impact with a solid target. The granular drops are formed from roughly spherical balls of sand mixed with water, which is used as a binder to hold the ball together during free-fall. We measure the instantaneous spread diameter for different impact speeds and find that the normalized spread diameter d/D grows as (tV/D)1/2. The speeds of the grains ejected during the “splash” are measured and they rarely exceed twice that of the impact speed.

  13. Impact of granular drops

    KAUST Repository

    Marston, J. O.; Mansoor, Mohammad M.; Thoroddsen, Sigurdur T

    2013-01-01

    We investigate the spreading and splashing of granular drops during impact with a solid target. The granular drops are formed from roughly spherical balls of sand mixed with water, which is used as a binder to hold the ball together during free-fall. We measure the instantaneous spread diameter for different impact speeds and find that the normalized spread diameter d/D grows as (tV/D)1/2. The speeds of the grains ejected during the “splash” are measured and they rarely exceed twice that of the impact speed.

  14. Mechanics of the foot Part 2: A coupled solid-fluid model to investigate blood transport in the pathologic foot.

    Science.gov (United States)

    Mithraratne, K; Ho, H; Hunter, P J; Fernandez, J W

    2012-10-01

    A coupled computational model of the foot consisting of a three-dimensional soft tissue continuum and a one-dimensional (1D) transient blood flow network is presented in this article. The primary aim of the model is to investigate the blood flow in major arteries of the pathologic foot where the soft tissue stiffening occurs. It has been reported in the literature that there could be up to about five-fold increase in the mechanical stiffness of the plantar soft tissues in pathologic (e.g. diabetic) feet compared with healthy ones. The increased stiffness results in higher tissue hydrostatic pressure within the plantar area of the foot when loaded. The hydrostatic pressure acts on the external surface of blood vessels and tend to reduce the flow cross-section area and hence the blood supply. The soft tissue continuum model of the foot was modelled as a tricubic Hermite finite element mesh representing all the muscles, skin and fat of the foot and treated as incompressible with transversely isotropic properties. The details of the mechanical model of soft tissue are presented in the companion paper, Part 1. The deformed state of the soft tissue continuum because of the applied ground reaction force at three foot positions (heel-strike, midstance and toe-off) was obtained by solving the Cauchy equations based on the theory of finite elasticity using the Galerkin finite element method. The geometry of the main arterial network in the foot was represented using a 1D Hermite cubic finite element mesh. The flow model consists of 1D Navier-Stokes equations and a nonlinear constitutive equation to describe vessel radius-transmural pressure relation. The latter was defined as the difference between the fluid and soft tissue hydrostatic pressure. Transient flow governing equations were numerically solved using the two-step Lax-Wendroff finite difference method. The geometry of both the soft tissue continuum and arterial network is anatomically-based and was developed using

  15. The Comparison of Ankle Muscles Isometric Strength and Foot Eversion in Male Individuals with Patellofemoral Pain Syndrome and Healthy Peers: A Case-Control Study

    Directory of Open Access Journals (Sweden)

    V. Mazloum

    2017-01-01

    Full Text Available Introduction: Proximal and distal factors to the knee joint can be assumed as etiology of patellofemoral pain syndrome (PFPS. Some distal factors include excessive foot pronation and medial tibia torsion. The purpose of this study was to compare ankle musculature strength and rearfoot eversion in individuals with and without PFPS. Methods: Forty males (20 healthy and 20 patients voluntarily participated in this case-control study. Isometric ankle dorsiflexor and invertor muscles strength, rearfoot eversion range of motion (ROM, and Navicular depression were respectively evaluated by handheld dynamometer, goniometry, and Navicular Drop Test by a single examiner for both groups. To analyze the measurements, Independent Samples t test for parametric data and Mann-Whitney U test for nonparametric data at P0.05. Furthermore, no significant differences were observed between patients with PFPS and healthy counterparts regarding rearfoot eversion and Navicular depression (P>0.05. Conclusion: It can be deduced that isometric ankle dorsiflexor and invertor muscles strength, rearfoot eversion ROM, and foot pronation are not difference in patients with PFPS and healthy persons. 

  16. Adaptation of running pattern to the drop of standard cushioned shoes: A randomised controlled trial with a 6-month follow-up.

    Science.gov (United States)

    Malisoux, Laurent; Gette, Paul; Chambon, Nicolas; Urhausen, Axel; Theisen, Daniel

    2017-08-01

    While several cross-sectional studies have investigated the acute effects of shoe drop on running biomechanics, the long-term consequences are currently unknown. This study aimed to investigate if the drop of standard cushioned shoes induces specific adaptations in running technique over a six-month period in leisure-time runners. Double-blinded randomised controlled trial. The participants (n=59) received a pair of shoes with a heel-to-toe drop of 10mm (D10), 6mm (D6) or 0mm (D0) and were followed-up regarding running training over 6 months or 500km, whichever came first. Spatio-temporal variables and kinematics (foot/ground, ankle and knee joint angles) were investigated while running at preferred speed on a treadmill before and after the follow-up. The participants ran 332±178km in the study shoes between pre- and post-tests. There was no shoe version by time interaction for any of the spatio-temporal variables nor for lower limb angles at initial ground contact. A small but significant shoe drop effect was found for knee abduction at mid-stance (p=0.032), as it decreased for the D0 version (-0.3±3.1 vs. -1.3±2.6°) while it increased for the D6 (0.3±2.7 vs. 1.3±3.1°) and D10 version (-0.2±3.2 vs. 0.5±3.1°). However, none of the pairwise comparisons was significant in the post-hoc analysis. Apart from knee abduction at mid-stance, no specific adaptation in spatio-temporal variables and kinematics was found between the three shoe versions during this 6-month follow-up. Thus, shoe drop of standard cushioned shoes does not seem to influence running biomechanics in the long term. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Implants in free fibula flap supporting dental rehabilitation - Implant and peri-implant related outcomes of a randomized clinical trial.

    Science.gov (United States)

    Kumar, Vinay V; Ebenezer, Supriya; Kämmerer, Peer W; Jacob, P C; Kuriakose, Moni A; Hedne, Naveen; Wagner, Wilfried; Al-Nawas, Bilal

    2016-11-01

    The objective of this study was to assess the difference in success rates of implants when using two or four implant-supported-overdentures following segmental mandibular reconstruction with fibula free flap. This prospective, parallel designed, randomized clinical study was conducted with 1:1 ratio. At baseline, all participants already had segmental reconstruction of mandible with free fibula flap. The participants were randomized into two groups: Group-I received implant-supported-overdentures on two tissue-level implants and Group-II received implant-supported-overdentures on four tissue-level implants. Success rates of the implants were evaluated at 3 months, 6 months and 12 months following implant loading using marginal bone level changes as well as peri-implant indices (Buser et al., 1990). 52 patients were randomized into two treatment groups (26 each), out of which 18 patients (36 implants) of Group-I and 17 patients (68 implants) of Group-II were evaluated. One implant in Group-I was lost due to infective complications and one patient in the same group had superior barrel necrosis. There was a statistically significant increase at both time points (p = 0.03, p = 0.04 at 6 months, 12 months) in the amount of marginal bone loss in Group-I (0.4 mm, 0.5 mm at 6 months, 12 months) as compared to Group-II (0.1 mm, 0.2 mm at 6 months, 12 months). There were no clinically significant changes peri-implant parameters between both groups. Peri-implant soft tissue hyperplasia was seen in both groups, 32% of implants at 3-months, 26% at 6-months and 3% at 12-months follow-up. The results of this study show that patients with 2-implant-supported-overdentures had higher marginal bone loss as compared to patients with 4-implant-supported-overdentures. There were no clinically significant differences in peri-implant soft tissue factors in patients with 2- or 4-implant-supported-overdentures. Hyperplastic peri-implant tissues are common in the early implant

  18. The influence of the program of prophylaxis of flat foot on the biomechanics characteristics of foot of children of pre-school age

    Directory of Open Access Journals (Sweden)

    Bychuk I.O.

    2011-02-01

    Full Text Available In the article is defined linear and angular biomechanics descriptions of children's foot of senior preschool age. It is analysed the dynamics and increase of the explored indexes during realization of the program of prophylaxis of flat foot in the teaching process. In experiment took part teachers and instructors of physical culture; control and experimental group consist of 20 children at the age of 5-6 years old. Efficiency of the offered program of prophylaxis of flat foot is proved.

  19. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  20. Impact analysis of shipping casks

    International Nuclear Information System (INIS)

    Pfeiffer, P.A.; Kennedy, J.M.

    1989-01-01

    This paper describes how simpler two- and three-dimensional models can be used to provide an intermediate level of detail between full three dimensional finite element calculations and hand calculation. Three free drop scenarios are analyzed to assess the integrity of the cask when subjected to large bending and axial stresses. These three drop scenarios are: a thirty foot axial drop on either end, a thirty foot oblique angel drop with the cask having several different orientations from the vertical with impact on the top end cask corner, and a thirty foot side drop with simultaneous impact on one of the lifting trunnions and the bottom end. Prevention of damage hinges on the strength of the various components that comprises the cask. The predicted levels of deformation and stresses in the cask are used to assess the potential damage level

  1. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  2. Phacoemulsification with intraocular lens implantation in primary angle-closure suspect, primary angle-closure and primary angle-closure glaucoma with cataract

    Directory of Open Access Journals (Sweden)

    Kun Zeng

    2013-08-01

    Full Text Available AIM: To evaluate the features and clinical outcomes of cataract extraction by phacoemulsification with intraocular lens implantation in primary angle-closure suspect(PACS, primary angle-closure(PACand primary angle-closure glaucoma(PACGwith cataract.METHODS:Phacoemulsification with intraocular lens implantation was performed on 86 cases(86 eyesdiagnosed as PACS, PAC and PACG co-existing cataract from January to December 2012. All cases were followed up for 3 months to 1 year. Pre-operative and post-operative visual acuity, intraocular pressure(IOP, gonioscopy, ultrasound biomicroscopy(UBM, visual field and usage of anti-glaucomaous eye drops were recorded.RESULTS:Zonular dialysis existed in 19 eyes(22%. The post-operative visual acuity improved in 84 eyes(98%. The post-operative visual acuity was CONCLUSION: PACS, PAC and PACG co-existing zonular dialysis is common. Phacoemulsification with IOL implantation can reduce IOP, deepen anterior chamber and open angle.

  3. Finite element modeling of a 3D coupled foot-boot model.

    Science.gov (United States)

    Qiu, Tian-Xia; Teo, Ee-Chon; Yan, Ya-Bo; Lei, Wei

    2011-12-01

    Increasingly, musculoskeletal models of the human body are used as powerful tools to study biological structures. The lower limb, and in particular the foot, is of interest because it is the primary physical interaction between the body and the environment during locomotion. The goal of this paper is to adopt the finite element (FE) modeling and analysis approaches to create a state-of-the-art 3D coupled foot-boot model for future studies on biomechanical investigation of stress injury mechanism, foot wear design and parachute landing fall simulation. In the modeling process, the foot-ankle model with lower leg was developed based on Computed Tomography (CT) images using ScanIP, Surfacer and ANSYS. Then, the boot was represented by assembling the FE models of upper, insole, midsole and outsole built based on the FE model of the foot-ankle, and finally the coupled foot-boot model was generated by putting together the models of the lower limb and boot. In this study, the FE model of foot and ankle was validated during balance standing. There was a good agreement in the overall patterns of predicted and measured plantar pressure distribution published in literature. The coupled foot-boot model will be fully validated in the subsequent works under both static and dynamic loading conditions for further studies on injuries investigation in military and sports, foot wear design and characteristics of parachute landing impact in military. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Properties of coherent vortex motion in Pb-Nb-Pb ion implant variable thickness bridges

    International Nuclear Information System (INIS)

    Crozat, P.; Vernet, G.; Adde, R.

    1980-01-01

    We report here on the dc and microwave properties of variable thickness ion implant Pb-Nb-Pb bridges which present characteristic feature of coherent vortex motion. These results follow from a choice of particular microbridge parameters which altogether constitute favorable conditions to have one row of vortices in the central part of the bridge: a/ Large Pb bank thickness D (500-800 nm) > lambdasub(Pb) such that vortices are strongly repelled by the banks. b/ The implantation of the Nb bridge brings film uniformity compared to the coherent length (inhomogeneities due to defects approx. equal to 5 nm), a large increase of lambdasub(eff) (400%) and resistance (200%) while xi drops only very slightly (10-15%). c/ As a consequence of b/bridges with micrometric dimensions are much smaller than lambdasub(eff). Therefore a single row of vortices is strongly repelled by both banks. (orig./WRI)

  5. [Trabeculotomy ab interno combined with extracapsular cataract extraction and IOL implantation].

    Science.gov (United States)

    Alekseev, B N; Ermolaev, A P

    2003-01-01

    We made a total of 96 surgeries of extracapsular cataract extraction and IOL implantation combined with trabeculotomy ab interno during a period of 7 years. Patients with both open-angle and narrow-angle glaucoma of stages I and II and with the intraocular pressure (IOP) below or equal to 23 mm Hg according to Goldman under the conditions of hypotensive medicamental regimen were selected for surgery. After IOL was implanted into the lens bag, trabeculotomy ab interno was implemented as stage 2. A special mirror, introduced through the cataract incision, was used for direct gonioscopic monitoring. The trabecula was incised by the edge of a curved surgical knife under direct visual control. We regarded bleeding from the opened sinus as a favorable sign indicative of that the intrascleral collectors were intact. Only minor hyphemas were registered as postoperative complications; there was not a single case of ciliary-and-choroidal detachment. IOP was compensated for, in 6 months after surgery, in 94% of patients--69.8% of them did not use any hypotensive drops.

  6. Foot ulcers in the diabetic patient, prevention and treatment

    Directory of Open Access Journals (Sweden)

    Stephanie C Wu

    2007-03-01

    Full Text Available Stephanie C Wu1, Vickie R Driver1, James S Wrobel2, David G Armstrong21Center for Lower Extremity Ambulatory Research,William M. Scholl College of Podiatric Medicine at Rosalind Franklin University of Medicine and Science, and National Center of Limb Salvage, Advocate Lutheran General Hospital, Chicago, IL, USA; 2Center for Lower Extremity Ambulatory Research, Dr. William M. Scholl College of Podiatric Medicine at Rosalind Franklin University of Medicine, Chicago, IL, USAAbstract: Lower extremity complications in persons with diabetes have become an increasingly significant public health concern in both the developed and developing world. These complications, beginning with neuropathy and subsequent diabetic foot wounds frequently lead to infection and lower extremity amputation even in the absence of critical limb ischemia. In order to diminish the detrimental consequences associated with diabetic foot ulcers, a common-sense-based treatment approach must be implemented. Many of the etiological factors contributing to the formation of diabetic foot ulceration may be identified using simple, inexpensive equipment in a clinical setting. Prevention of diabetic foot ulcers can be accomplished in a primary care setting with a brief history and screening for loss of protective sensation via the Semmes-Weinstein monofilament. Specialist clinics may quantify neuropathy, plantar foot pressure, and assess vascular status with Doppler ultrasound and ankle-brachial blood pressure indices. These measurements, in conjunction with other findings from the history and physical examination, may enable clinicians to stratify patients based on risk and help determine the type of intervention. Other effective clinical interventions may include patient education, optimizing glycemic control, smoking cessation, and diligent foot care. Recent technological advanced combined with better understanding of the wound healing process have resulted in a myriad of advanced

  7. Plantar loading changes with alterations in foot strike patterns during a single session in habitual rear foot strike female runners.

    Science.gov (United States)

    Kernozek, Thomas W; Vannatta, Charles N; Gheidi, Naghmeh; Kraus, Sydnie; Aminaka, Naoko

    2016-03-01

    Characterize plantar loading parameters when habitually rear foot strike (RFS) runners change their pattern to a non-rear foot strike (NRFS). Experimental. University biomechanics laboratory. Twenty three healthy female runners (Age: 22.17 ± 1.64 yrs; Height: 168.91 ± 5.46 cm; Mass: 64.29 ± 7.11 kg). Plantar loading was measured using an in-sole pressure sensor while running down a 20-m runway restricted to a range of 3.52-3.89 m/s under two conditions, using the runner's typical RFS, and an adapted NRFS pattern. Repeated measures multivariate analysis of variance was performed to detect differences in loading between these two conditions. Force and pressure variables were greater in the forefoot and phalanx in NRFS and greater in the heel and mid foot in RFS pattern, but the total force imposed upon the whole foot and contact time remained similar between conditions. Total peak pressure was higher and contact area was lower during NRFS running. The primary finding of this investigation is that there are distinctly different plantar loads when changing from a RFS to NRFS during running. So, during a transition from RFS to a NRFS pattern; a period of acclimation should be considered to allow for adaptations to these novel loads incurred on plantar regions of the foot. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Diabetic Foot Risk Factors in Patients with Diabetes at the

    Directory of Open Access Journals (Sweden)

    R. Hosseini

    2008-10-01

    Full Text Available Background and Objectives Diabetic foot problems are one of the major causes of mortality and disability in diabetic patients. It is considered one of the costliest conditions for health care systems. This study is designed to identify diabetic foot risk factors in patients with diabetes mellitus at Kamkar Hospital diabetes clinic in Qom, Iran during 2006.MethodsThis study was performed on 140 diabetes mellitus patients at the Kamkar Hospital diabetic clinic. International working Group on the Diabetic Foot (IWGDF guidelines were used for physical exam of diabetic foot in these patients. The physical exam consisted of inspection of foot appearance for deformity, skin keratosis and ulcer, and neurological and arterial pulse exam of the lower extremities of these patients. Patients in this study were divided into four risk groups based on the IWGDF guidelines. ANOVA method was used for analysis and comparison of the results with P<0.05 considered as significant. ResultsMean age of the participants in this study was 52.4±11.2 years old from which 67.1% were female, 37.1% of patients were illiterate, and 10% were active smokers. Mean duration of diabetes in these patients was 8.9 years. Mean body mass index (BMI was 29.4± 4.4 and HbA1C was 9.3 ± 1.9. Percentages of the patients with retinopathy and nephropathy were 33.6% and 17.7% respectively. 95% of the patients did not know the correct way of nail clipping, 95.5% were wearing uncomfortable shoes, and 14.3% of patients had history of foot ulcer. None of the them had any education about foot care. Physical examination with monofilament, ankle reflex and vibration perception were defected in 28.6%, 52.5%, and 32.1% of patients respectively. 37.7% of patients had a decreased lower extremity pulse that was not felt by touch. Based on the IWGDF classifications, 70% of the patients were in the higher-risk group for diabetic foot ulcer. In the high risk group, age, duration of diabetes, illiteracy was

  9. Assessment of Lumped-Parameter Models for Rigid Footings

    DEFF Research Database (Denmark)

    Andersen, Lars

    2010-01-01

    and vertical translations as well as torsion and rocking, and the necessity of coupling between horizontal sliding and rocking is discussed. Most of the analyses are carried out for hexagonal footings; but in order to generalise the conclusions to a broader variety of footings, comparisons are made...

  10. Risk factors for developing diabetic foot

    Directory of Open Access Journals (Sweden)

    Julia Estela Willrich Boell

    2014-06-01

    Full Text Available The goal of the present study is to identify the risk factors for developing diabetic foot. A cross-sectional study, with a convenience sample, developed with 70 individuals with diabetes mellitus (DM, registered in three basic health units in the municipality of Florianópolis/SC, Brazil, in the period from November 2010 to May 2011. Biometric data was collected regarding their sociodemographic, health and illness conditions. An assessment of the feet was also carried out. The average participant age was 66.17 years and time with diagnosed disease was under ten years (61.42%. The following risk factors were identified: advanced age; time of DM diagnosis; few years of schooling; overweight/obesity; inadequate diet; physical inactivity; inadequate metabolic control; lack of proper and specific foot care; and arterial hypertension. We conclude that the majority of the population presented one or more risk factors that favor the appearance of foot-related complications. doi: 10.5216/ree.v16i2.20460.

  11. Off-label prescriptions in diabetic foot

    Directory of Open Access Journals (Sweden)

    Luís Jesuíno de Oliveira Andrade

    2014-09-01

    Full Text Available Prescription of a drug outside of the indications for which it was originally approved by regulators is internationally known as "off-label" prescription. We describe off-label treatments for the diabetic foot reported in international scientific literature. This is a qualitative and descriptive bibliographical review based on the results of a search of the Medline international database. The criteria for review were publication between January 1985 and November 2013, and the MeSH (Medical Subject Heading keywords "off-label use" OR "off-label" OR "off-label prescribing" plus "diabetic foot" were input on the search form. Nine studies were selected that contained information about off-label treatments for the diabetic foot. We conclude that the practice of off-label prescribing has potential benefits. In some situations an off-label prescription is the only treatment available for patients, either because a more targeted drug does not exist, or because other methods of treatment are ineffective or unavailable due to patient intolerance.

  12. Managing the diabetic foot in resource-poor settings: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Abbas ZG

    2017-10-01

    Full Text Available Zulfiqarali G Abbas1,2 1Department of Internal Medicine, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania; 2Department of Internal Medicine, Abbas Medical Centre, Dar es Salaam, Tanzania Abstract: Diabetes mellitus is one of the most common noncommunicable diseases globally. In Africa, rates of diabetes are increasing, so there is a parallel increase of foot complications. Peripheral neuropathy is the main risk factor for foot ulceration in people with diabetes in developing nations, but peripheral arterial disease is also increasing in number owing to the change in lifestyle and increasing urbanization. Ulceration arising from peripheral neuropathy, peripheral arterial disease, and trauma are highly susceptible to secondary infection and gangrene, and are hence associated with increased morbidity and mortality. Government funding is very limited in many developing countries, and diabetes and its complications impose a heavy burden on health services. In particular, the outcomes of foot complications are often poor, and this is the result of various factors including lack of awareness of the need for foot care among patients, relatives, and health care providers; relatively few professionals with an interest in the diabetic foot and with the training to provide specialist treatment; nonexistent podiatry services; long distances for patients to travel to the clinic; delays among patients in seeking medical care, or the late referral of patients for specialist opinion; and lack of the awareness of the importance of a team approach to care, and the lack of training programs for health care professionals. Many of these can, however, potentially be tackled without exorbitant spending of financial resources. Cost-effective educational efforts should be targeted at both health care workers and patients. These include implementation of sustainable training programs for health care professionals with a special interest in foot

  13. Bone tumors of the pediatric foot: imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Caro-Dominguez, Pablo; Navarro, Oscar M. [University of Toronto, Department of Medical Imaging, Toronto, ON (Canada); The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2017-05-15

    Tumors of the foot are rare in children. This review illustrates radiographic, CT and MR imaging findings of foot bone tumors in children based on all cases presented in a tertiary pediatric hospital during the 15-year period of 1999-2014. This search revealed 155 tumors of the foot, 72 of the bones and 83 of the soft tissues. Osteochondroma, bone cyst and fibrous dysplasia were the most frequent benign bone lesions. Ewing sarcoma was the most common malignant osseous tumor. Some tumors showed higher prevalence in certain age ranges and others showed predilection for specific bones. Radiographs are useful for diagnosis in the majority of cases but CT and MR imaging provide additional valuable information in select cases for diagnosis and determining extent of the lesions. Radiologists should be aware of some typical imaging findings in bone tumors of the foot in order to establish diagnosis and facilitate patient management. (orig.)

  14. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  15. Bubble and Drop Nonlinear Dynamics (BDND)

    Science.gov (United States)

    Trinh, E. H.; Leal, L. Gary; Thomas, D. A.; Crouch, R. K.

    1998-01-01

    Free drops and bubbles are weakly nonlinear mechanical systems that are relatively simple to characterize experimentally in 1-G as well as in microgravity. The understanding of the details of their motion contributes to the fundamental study of nonlinear phenomena and to the measurement of the thermophysical properties of freely levitated melts. The goal of this Glovebox-based experimental investigation is the low-gravity assessment of the capabilities of a modular apparatus based on ultrasonic resonators and on the pseudo- extinction optical method. The required experimental task is the accurate measurements of the large-amplitude dynamics of free drops and bubbles in the absence of large biasing influences such as gravity and levitation fields. A single-axis levitator used for the positioning of drops in air, and an ultrasonic water-filled resonator for the trapping of air bubbles have been evaluated in low-gravity and in 1-G. The basic feasibility of drop positioning and shape oscillations measurements has been verified by using a laptop-interfaced automated data acquisition and the optical extinction technique. The major purpose of the investigation was to identify the salient technical issues associated with the development of a full-scale Microgravity experiment on single drop and bubble dynamics.

  16. Drop Testing Representative Multi-Canister Overpacks

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Spencer D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Morton, Dana K. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    The objective of the work reported herein was to determine the ability of the Multi- Canister Overpack (MCO) canister design to maintain its containment boundary after an accidental drop event. Two test MCO canisters were assembled at Hanford, prepared for testing at the Idaho National Engineering and Environmental Laboratory (INEEL), drop tested at Sandia National Laboratories, and evaluated back at the INEEL. In addition to the actual testing efforts, finite element plastic analysis techniques were used to make both pre-test and post-test predictions of the test MCOs structural deformations. The completed effort has demonstrated that the canister design is capable of maintaining a 50 psig pressure boundary after drop testing. Based on helium leak testing methods, one test MCO was determined to have a leakage rate not greater than 1x10-5 std cc/sec (prior internal helium presence prevented a more rigorous test) and the remaining test MCO had a measured leakage rate less than 1x10-7 std cc/sec (i.e., a leaktight containment) after the drop test. The effort has also demonstrated the capability of finite element methods using plastic analysis techniques to accurately predict the structural deformations of canisters subjected to an accidental drop event.

  17. Cold immersion recovery responses in the diabetic foot with neuropathy.

    Science.gov (United States)

    Bharara, Manish; Viswanathan, Vijay; Cobb, Jonathan E

    2008-10-01

    The aim of this article was to investigate the effectiveness of testing cold immersion recovery responses in the diabetic foot with neuropathy using a contact thermography system based on thermochromic liquid crystals. A total of 81 subjects with no history of diabetic foot ulceration were assigned to neuropathy, non neuropathy and healthy groups. Each group received prior verbal and written description of the test objectives and subsequently underwent a comprehensive foot care examination. The room temperature and humidity were consistently maintained at 24 degrees C and less than 50%, respectively, with air conditioning. The right foot for each subject was located on the measurement platform after cold immersion in water at 18-20 degrees C. Whole-field thermal images of the plantar foot were recorded for 10 minutes. Patients with diabetes with neuropathy show the highest 'delta temperature', that is difference between the temperature after 10-minute recovery period and baseline temperature measured independently at all the three sites tested, that is first metatarsal head (MTH), second MTH and heel. This clinical study showed for the first time the evidence of poor recovery times for the diabetic foot with neuropathy when assessing the foot under load. A temperature deficit (because of poor recovery to baseline temperature) suggests degeneration of thermoreceptors, leading to diminished hypothalamus-mediated activity in the diabetic neuropathic group.

  18. Anaplerosis in Complex Treatment of Patients with Diabetic Foot Syndrome

    Directory of Open Access Journals (Sweden)

    B.G. Bezrodny

    2015-05-01

    Full Text Available The article describes the improvement of anaplerosis in patients with diabetic foot syndrome using skin flaps on vascular pedicle of the perforating vessels. The study involved patients with type 2 diabetes mellitus complicated with diabetic foot syndrome of neuroischemic form and chronic wounds of the lower extremities that do not heal for more than 21 days from the date of occurrence. The wounds were cleaned with ultrasonic cavitation. There was applied bandage with sorption antibacterial remedy base on nanodispersed silicon dioxide. There was applied a drainage vacuum bandage on a wound on the third day (VAC therapy. The flap is forming fitting to the size and configuration of a wound on a foot. Fourteen patients (93 % in the basic group were found to have survived flaps. Long-term follow up in 6 months demonstrated full maintenance of supporting function and good survived skin graft, absence of foot ulcers. In a control group 7 patients had recurrent foot ulcer. Improved techniques of autodermoplasty in patients with diabetic foot syndrome include glycemia control, preparation of a wound using vacuum apparatus bandage. Usage of split-skin graft combined with vacuum apparatus bandage allows close acute and chronic wounds effectively, maintain supporting function of an extremity, decrease in-hospital staying, and improve quality of patient’s life. Adequate foot wound closure prevents high-level amputation of low extremities in diabetic patients.

  19. Spent Nuclear Fuel (SNF) Bounding Drop Support Calculations

    International Nuclear Information System (INIS)

    CHENAULT, D.M.

    1999-01-01

    This report evaluates different drop heights, concrete and other impact media to which the transport package and/or the MCO is dropped. A prediction method is derived for estimating the resultant impact factor for determining the bounding drop case for the SNF Project

  20. Wetting and evaporation of binary mixture drops.

    Science.gov (United States)

    Sefiane, Khellil; David, Samuel; Shanahan, Martin E R

    2008-09-11

    Experimental results on the wetting behavior of water, methanol, and binary mixture sessile drops on a smooth, polymer-coated substrate are reported. The wetting behavior of evaporating water/methanol drops was also studied in a water-saturated environment. Drop parameters (contact angle, shape, and volume) were monitored in time. The effects of the initial relative concentrations on subsequent evaporation and wetting dynamics were investigated. Physical mechanisms responsible for the various types of wetting behavior during different stages are proposed and discussed. Competition between evaporation and hydrodynamic flow are evoked. Using an environment saturated with water vapor allowed further exploration of the controlling mechanisms and underlying processes. Wetting stages attributed to differential evaporation of methanol were identified. Methanol, the more volatile component, evaporates predominantly in the initial stage. The data, however, suggest that a small proportion of methanol remained in the drop after the first stage of evaporation. This residual methanol within the drop seems to influence subsequent wetting behavior strongly.

  1. The reliability of the Adelaide in-shoe foot model.

    Science.gov (United States)

    Bishop, Chris; Hillier, Susan; Thewlis, Dominic

    2017-07-01

    Understanding the biomechanics of the foot is essential for many areas of research and clinical practice such as orthotic interventions and footwear development. Despite the widespread attention paid to the biomechanics of the foot during gait, what largely remains unknown is how the foot moves inside the shoe. This study investigated the reliability of the Adelaide In-Shoe Foot Model, which was designed to quantify in-shoe foot kinematics and kinetics during walking. Intra-rater reliability was assessed in 30 participants over five walking trials whilst wearing shoes during two data collection sessions, separated by one week. Sufficient reliability for use was interpreted as a coefficient of multiple correlation and intra-class correlation coefficient of >0.61. Inter-rater reliability was investigated separately in a second sample of 10 adults by two researchers with experience in applying markers for the purpose of motion analysis. The results indicated good consistency in waveform estimation for most kinematic and kinetic data, as well as good inter-and intra-rater reliability. The exception is the peak medial ground reaction force, the minimum abduction angle and the peak abduction/adduction external hindfoot joint moments which resulted in less than acceptable repeatability. Based on our results, the Adelaide in-shoe foot model can be used with confidence for 24 commonly measured biomechanical variables during shod walking. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The effect of age and speed on foot and ankle kinematics assessed using a 4-segment foot model.

    Science.gov (United States)

    van Hoeve, Sander; Leenstra, Bernard; Willems, Paul; Poeze, Martijn; Meijer, Kenneth

    2017-09-01

    The effects of age and speed on foot and ankle kinematics in gait studies using foot models are not fully understood, whereas this can have significant influence. We analyzed these variables with the 4-segment Oxford foot model. Twenty-one healthy subjects (aged 20-65 years) were recruited for gait analysis. The effect of speed on foot and ankle kinematics was assessed by comparing results during slow walking and fast walking. To assess the effect of age, a group of 13 healthy young adults (aged 20-24 years) were compared with a group of 8 older adults (aged 53-65 years). Also, the interaction between age and speed was analyzed. Regarding speed, there was a significant difference between forefoot/hindfoot motion in the sagittal plane (flexion/extension) during both loading- and push-off phase (P = .004, P < .001). Between hindfoot/tibia, there was a significant difference for all parameters except for motion in the sagittal plane (flexion/extension) during push-off phase (P = .5). Age did not significantly influence kinematics. There was no interaction between age and speed. Our analysis found that speed significantly influenced the kinematic outcome parameters. This was more pronounced in the ankle joint. In contrast, no significant differences were found between younger and older healthy subjects.

  3. The effect of age and speed on foot and ankle kinematics assessed using a 4-segment foot model

    Science.gov (United States)

    van Hoeve, Sander; Leenstra, Bernard; Willems, Paul; Poeze, Martijn; Meijer, Kenneth

    2017-01-01

    Abstract Background: The effects of age and speed on foot and ankle kinematics in gait studies using foot models are not fully understood, whereas this can have significant influence. We analyzed these variables with the 4-segment Oxford foot model. Methods: Twenty-one healthy subjects (aged 20–65 years) were recruited for gait analysis. The effect of speed on foot and ankle kinematics was assessed by comparing results during slow walking and fast walking. To assess the effect of age, a group of 13 healthy young adults (aged 20–24 years) were compared with a group of 8 older adults (aged 53–65 years). Also, the interaction between age and speed was analyzed. Results: Regarding speed, there was a significant difference between forefoot/hindfoot motion in the sagittal plane (flexion/extension) during both loading- and push-off phase (P = .004, P push-off phase (P = .5). Age did not significantly influence kinematics. There was no interaction between age and speed. Conclusion: Our analysis found that speed significantly influenced the kinematic outcome parameters. This was more pronounced in the ankle joint. In contrast, no significant differences were found between younger and older healthy subjects. PMID:28858109

  4. Ankle and foot tuberculosis: A diagnostic dilemma

    Directory of Open Access Journals (Sweden)

    Biswaranjan Nayak

    2014-01-01

    Full Text Available Aim and Objective: To know the biological behavior of ankle and foot tuberculosis (AFTB and to know the reasons for delay in diagnosis and treatment of AFTB in our population. Materials and Methods: Patients with non-healing ulcers/sinuses/swellings in the ankle and foot region are the subjects of present study. Detailed clinical history, physical examination and relevant investigations were done in all cases. Pus/wound discharge for acid fast bacillus (AFB study and biopsy from wound margin/sinus tract was taken in all the cases. Results: During the period from July 2007-June 2012, 20 cases of AFTB were treated. Out of them five cases were difficult to diagnose and a mean period of 6 month to 5year was elapsed before final diagnosis was established. Out of these five cases - three cases were diabetic with ulcers and sinuses in the heel and ankle region. One case was wrongly diagnosed as angiodysplasia with A-V malformation of foot and diagnosis was delayed for 5 year. In one case of rheumatoid arthritis with abscess in ankle joint, the diagnosis was delayed for 1year. Conclusion: AFTB is very rare condition. AFTB is suspected in cases with long standing pain/swelling/discharging sinus in the foot and thorough investigations is must to differentiate from other foot diseases. Diagnosis is delayed due to lack of clinical suspicion and non-confirmatory biopsy reports. Early diagnosis and ATT for 9-18 months is must in all cases of AFTB to prevent joint involvement and other complications.

  5. Australian Diabetes Foot Network: management of diabetes-related foot ulceration - a clinical update.

    Science.gov (United States)

    Bergin, Shan M; Gurr, Joel M; Allard, Bernard P; Holland, Emma L; Horsley, Mark W; Kamp, Maarten C; Lazzarini, Peter A; Nube, Vanessa L; Sinha, Ashim K; Warnock, Jason T; Alford, Jan B; Wraight, Paul R

    2012-08-20

    Appropriate assessment and management of diabetes-related foot ulcers (DRFUs) is essential to reduce amputation risk. Management requires debridement, wound dressing, pressure off-loading, good glycaemic control and potentially antibiotic therapy and vascular intervention. As a minimum, all DRFUs should be managed by a doctor and a podiatrist and/or wound care nurse. Health professionals unable to provide appropriate care for people with DRFUs should promptly refer individuals to professionals with the requisite knowledge and skills. Indicators for immediate referral to an emergency department or multidisciplinary foot care team (MFCT) include gangrene, limb-threatening ischaemia, deep ulcers (bone, joint or tendon in the wound base), ascending cellulitis, systemic symptoms of infection and abscesses. Referral to an MFCT should occur if there is lack of wound progress after 4 weeks of appropriate treatment.

  6. Long time follow up of implant therapy and treatment of peri-implantitis.

    Science.gov (United States)

    Roos-Jansåker, Ann-Marie

    2007-01-01

    Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on

  7. Patients With Diabetic Foot Disease Fear Major Lower-Extremity Amputation More Than Death.

    Science.gov (United States)

    Wukich, Dane K; Raspovic, Katherine M; Suder, Natalie C

    2018-02-01

    The aim of this study was to identify the most-feared complications of diabetes mellitus (DM), comparing those with diabetic foot pathology with those without diabetic foot pathology. We determined the frequency of patients ranking major lower-extremity amputation (LEA) as their greatest fear in comparison to blindness, death, diabetic foot infection (DFI), or end-stage renal disease (ESRD) requiring dialysis. We further categorized the study group patients (N = 207) by their pathology such as diabetic foot ulcer (DFU), Charcot neuroarthropathy, foot infection, or acute neuropathic fractures and dislocations. The control group (N = 254) was comprised of patients with diabetes who presented with common non-diabetes-related foot pathology. A total of 461 patients were enrolled in this study and included 254 patients without diabetic foot complications and 207 patients with diabetic foot problems. When comparing patients with and without diabetic disease, no significant differences were observed with regard to their fear of blindness, DFI, or ESRD requiring dialysis. Patients with diabetic foot disease (61 of 207, 31.9%) were 136% more likely (odds ratio [OR] = 2.36; 95% CI = 1.51-3.70; P = .002] to rank major LEA as their greatest fear when compared with diabetic patients without foot disease (42 of 254, 16.5%) and were 49% less likely (OR = 0.51; 95% CI = 0.34-0.79; P = .002) to rank death as their greatest fear compared with patients without diabetic foot disease. Patients with diabetic foot pathology fear major LEA more than death, foot infection, or ESRD. Variables that were associated with ranking LEA as the greatest fear were the presence of a diabetic-related foot complication, duration of DM ≥10 years, insulin use, and the presence of peripheral neuropathy. Level II: Prospective, Case controlled study.

  8. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  9. THE FEASIBILITY OF HIND FOOT AMPUTATION IN SELECTED SARCOMAS OF THE FOOT

    NARCIS (Netherlands)

    HAM, SJ; HOEKSTRA, HJ; EISMA, WH; OLDHOFF, J; KOOPS, HS

    The treatment of foot sarcomas is generally a below knee amputation. In selected sarcomas of the forefoot, however, a transtarsal amputation according to Chopart, a calcaneotibial arthrodesis according to Pirogoff, or a supramalleolar amputation according to Syme can be considered the treatment of

  10. Enhancing the antibacterial performance of orthopaedic implant materials by fibre laser surface engineering

    Science.gov (United States)

    Chan, Chi-Wai; Carson, Louise; Smith, Graham C.; Morelli, Alessio; Lee, Seunghwan

    2017-05-01

    Implant failure caused by bacterial infection is extremely difficult to treat and usually requires the removal of the infected components. Despite the severe consequence of bacterial infection, research into bacterial infection of orthopaedic implants is still at an early stage compared to the effort on enhancing osseointegration, wear and corrosion resistance of implant materials. In this study, the effects of laser surface treatment on enhancing the antibacterial properties of commercially pure (CP) Ti (Grade 2), Ti6Al4V (Grade 5) and CoCrMo alloy implant materials were studied and compared for the first time. Laser surface treatment was performed by a continuous wave (CW) fibre laser with a near-infrared wavelength of 1064 nm in a nitrogen-containing environment. Staphylococcus aureus, commonly implicated in infection associated with orthopaedic implants, was used to investigate the antibacterial properties of the laser-treated surfaces. The surface roughness and topography of the laser-treated materials were analysed by a 2D roughness testing and by AFM. The surface morphologies before and after 24 h of bacterial cell culture were captured by SEM, and bacterial viability was determined using live/dead staining. Surface chemistry was analysed by XPS and surface wettability was measured using the sessile drop method. The findings of this study indicated that the laser-treated CP Ti and Ti6Al4V surfaces exhibited a noticeable reduction in bacterial adhesion and possessed a bactericidal effect. Such properties were attributable to the combined effects of reduced hydrophobicity, thicker and stable oxide films and presence of laser-induced nano-features. No similar antibacterial effect was observed in the laser-treated CoCrMo.

  11. Drop-out from a psychodynamic group psychotherapy outpatient unit.

    Science.gov (United States)

    Jensen, Hans Henrik; Mortensen, Erik Lykke; Lotz, Martin

    2014-11-01

    BACKGROUND. Drop-out from psychotherapy is common and represents a considerable problem in clinical practice and research. Aim. To explore pre-treatment predictors of early and late drop-out from psychodynamic group therapy in a public outpatient unit for non-psychotic disorders in Denmark. Methods. Naturalistic design including 329 patients, the majority with mood, neurotic and personality disorders referred to 39-session group therapy. Predictors were socio-demographic and clinical variables, self-reported symptoms (Symptom Check List-90-Revised) and personality style (Millon Clinical Multiaxial Inventory-II). Drop-out was classified into early and late premature termination excluding patients who dropped out for external reasons. Results. Drop-out comprised 20.6% (68 patients) of the sample. Logistic regression revealed social functioning, vocational training, alcohol problems and antisocial behavior to be related to drop-out. However, early drop-outs had prominent agoraphobic symptoms, lower interpersonal sensitivity and compulsive personality features, and late drop-outs cognitive and somatic anxiety symptoms and antisocial personality features. Clinical and psychological variables accounted for the major part of variance in predictions of drop-out, which ranged from 15.6% to 19.5% (Nagelkerke Pseudo R-Square). Conclusion. Social functioning was consistently associated with drop-out, but personality characteristics and anxiety symptoms differentiated between early and late drop-out. Failure to discriminate between stages of premature termination may explain some of the inconsistencies in the drop-out literature. Clinical implications. Before selection of patients to time-limited psychodynamic groups, self-reported symptoms should be thoroughly considered. Patients with agoraphobic symptoms should be offered alternative treatment. Awareness of and motivation to work with interpersonal issues may be essential for compliance with group therapy.

  12. Reducing Variability in Stress Drop with Root-Mean Acceleration

    Science.gov (United States)

    Crempien, J.; Archuleta, R. J.

    2012-12-01

    Stress drop is a fundamental property of the earthquake source. For a given tectonic region stress drop is assumed to be constant allowing for the scaling of earthquake spectra. However, the variability of the stress drop, either for worldwide catalogs or regional catalogs, is quite large. The variability around the median value is on the order of 1.5 in log10 units. One question that continues to pervade the analysis of stress drop is whether this variability is an inherent characteristic of the Earth or is an artifact of the determination of stress drop via the use of the spectral analysis. It is simple to see that the stress drop determined by seismic moment times corner frequency cubed that errors in the corner frequency will strongly influence the variability in the stress drop. To avoid this strong dependence on corner frequency cubed, we have examined the determination of stress drop based on the approach proposed by Hanks (1979), namely using the root-mean-square acceleration. The stress drop determined using rms acceleration may be advantageous because the stress drop is only affected by the square root of the corner frequency. To test this approach we have determined stress drops for the 2000 Tottori earthquake and its aftershocks. We use both the classic method of fitting to a spectrum as well as using rms acceleration. For a preliminary analysis of eight aftershocks and the mainshock we find that the variability in stress drop is reduced by about a factor of two. This approach needs more careful analysis of more events, which will be shown at the meeting.

  13. Why Do Students Drop Advanced Mathematics?

    Science.gov (United States)

    Horn, Ilana

    2004-01-01

    Students, especially black, Latino and Native American youth and students of low socio-economic status drop out of advanced mathematics. Teachers must coordinate their expectations, their knowledge of students and their teaching practices in order to stop struggling students from dropping out of advanced math classes.

  14. Veterinary realities: what is foot and mouth disease?

    NARCIS (Netherlands)

    Law, J.; Mol, A.

    2011-01-01

    Veterinary science draws on different traditions for knowing and acting, and mobilises different kinds of materials and techniques. This article explores these differences and their tensions for the diagnosis of foot and mouth disease in the UK in 2001. It shows that when they talk of foot and mouth

  15. Landing Control of Foot with Springs for Walking Robots on Rough Terrain

    Directory of Open Access Journals (Sweden)

    Moyuru Yamada

    2009-09-01

    Full Text Available Landing control is one of the important issues for biped walking robot, because robots are expected to walk on not only known flat surfaces but also unknown and uneven terrain for working at various fields. This paper presents a new controller design for a robotic foot to land on unknown terrain. The robotic foot considered in this study equips springs to reduce the impact force at the foot landing. There are two objectives in the landing control; achieving the desired ground reaction force and positioning the foot on unknown terrain. To achieve these two objectives simultaneously by adjusting the foot position, we propose a PI force controller with a desired foot position, which guarantees the robust stability of control system with respect to terrain variance, and exact positioning of the foot to unknown terrain. Simulation results using the Open Dynamics Engine demonstrate the effectiveness of the proposed controller.

  16. Delayed frost growth on jumping-drop superhydrophobic surfaces.

    Science.gov (United States)

    Boreyko, Jonathan B; Collier, C Patrick

    2013-02-26

    Self-propelled jumping drops are continuously removed from a condensing superhydrophobic surface to enable a micrometric steady-state drop size. Here, we report that subcooled condensate on a chilled superhydrophobic surface are able to repeatedly jump off the surface before heterogeneous ice nucleation occurs. Frost still forms on the superhydrophobic surface due to ice nucleation at neighboring edge defects, which eventually spreads over the entire surface via an interdrop frost wave. The growth of this interdrop frost front is shown to be up to 3 times slower on the superhydrophobic surface compared to a control hydrophobic surface, due to the jumping-drop effect dynamically minimizing the average drop size and surface coverage of the condensate. A simple scaling model is developed to relate the success and speed of interdrop ice bridging to the drop size distribution. While other reports of condensation frosting on superhydrophobic surfaces have focused exclusively on liquid-solid ice nucleation for isolated drops, these findings reveal that the growth of frost is an interdrop phenomenon that is strongly coupled to the wettability and drop size distribution of the surface. A jumping-drop superhydrophobic condenser minimized frost formation relative to a conventional dropwise condenser in two respects: preventing heterogeneous ice nucleation by continuously removing subcooled condensate, and delaying frost growth by limiting the success of interdrop ice bridge formation.

  17. Clinical management of acute diabetic Charcot foot in Denmark

    DEFF Research Database (Denmark)

    Jansen, Rasmus Bo; Svendsen, Ole Lander; Kirketerp-Møller, Klaus

    2016-01-01

    INTRODUCTION: Charcot foot is a severe complication to diabetes mellitus and treatment involves several different clinical specialities. Our objective was to describe the current awareness, knowledge and treatment practices of Charcot foot among doctors who handle diabetic foot disorders. METHODS...... for offloading (83%). All centres use some form of a multidisciplinary team, with the most common permanent members being orthopaedic surgeons (71%), wound specialist nurses (76%), podiatrists (65%), endocrinologists (47%) and diabetes specialist nurses (41%). CONCLUSION: We conducted a survey of the diagnosis...

  18. Foot Pedals for Spacecraft Manual Control

    Science.gov (United States)

    Love, Stanley G.; Morin, Lee M.; McCabe, Mary

    2010-01-01

    Fifty years ago, NASA decided that the cockpit controls in spacecraft should be like the ones in airplanes. But controls based on the stick and rudder may not be best way to manually control a vehicle in space. A different method is based on submersible vehicles controlled with foot pedals. A new pilot can learn the sub's control scheme in minutes and drive it hands-free. We are building a pair of foot pedals for spacecraft control, and will test them in a spacecraft flight simulator.

  19. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  20. Foot disorders in dairy cattle: impact on cow and dairy farmer

    NARCIS (Netherlands)

    Bruijnis, M.R.N.; Beerda, B.; Hogeveen, H.; Stassen, E.N.

    2012-01-01

    This paper considers the economic consequences and the welfare impact of foot disorders in dairy cattle and the association between them, taking into account clinical and subclinical foot disorders. In dairy farming with cubicle housing and concrete floors, foot disorders are a major welfare problem

  1. Parents: Avoid Kids Foot Problems with the Right Shoes

    Science.gov (United States)

    ... Print | Share Avoid Kids Foot Problems with the Right Shoes Before you head to the store to ... College of Foot and Ankle Surgeons (ACFAS), All Rights Reserved. Privacy Statement | Disclaimer | Terms and Conditions | Site ...

  2. Hanging drop crystal growth apparatus and method

    Science.gov (United States)

    Carter, Daniel C. (Inventor); Smith, Robbie E. (Inventor)

    1989-01-01

    An apparatus (10) is constructed having a cylindrical enclosure (16) within which a disc-shaped wicking element (18) is positioned. A well or recess (22) is cut into an upper side (24) of this wicking element, and a glass cover plate or slip (28) having a protein drop disposed thereon is sealably positioned on the wicking element (18), with drop (12) being positioned over well or recess (22). A flow of control fluid is generated by a programmable gradient former (16), with this control fluid having a vapor pressure that is selectively variable. This flow of control fluid is coupled to the wicking element (18) where control fluid vapor diffusing from walls (26) of the recess (22) is exposed to the drop (12), forming a vapor pressure gradient between the drop (12) and the control fluid vapor. Initially, this gradient is adjusted to draw solvent from the drop (12) at a relatively high rate, and as the critical supersaturation point is approached (the point at which crystal nucleation occurs), the gradient is reduced to more slowly draw solvent from the drop (12). This allows discrete protein molecules more time to orient themselves into an ordered crystalline lattice, producing protein crystals which, when processed by X-ray crystallography, possess a high degree of resolution.

  3. The Effect of Foot Exercises on Wound Healing in Type 2 Diabetic Patients With a Foot Ulcer: A Randomized Control Study.

    Science.gov (United States)

    Eraydin, Şahizer; Avşar, Gülçin

    The purpose of this study was to investigate the effect of foot exercises on wound healing in type 2 diabetic patients with a diabetic foot ulcer. Prospective, randomized controlled study. Sixty-five patients from an outpatient clinic with grade 1 or 2 ulcers (Wagner classification) who met study criteria agreed to participate; 60 patients completed the study and were included in the final analysis. Subjects were followed up between February 2014 and June 2015. Subjects were recruited by the researchers in the clinics where they received treatment. Subjects were randomly allocated to either the control or intervention group. Data were collected using investigator-developed forms: patient information form and the diabetic foot exercises log. Patients in the intervention group received standard wound care and performed daily foot exercises for 12 weeks; the control group received standard wound care but no exercises. The ulcers of the patients in both the intervention and control groups were examined and measured at the 4th, 8th, and 12th weeks. The groups were compared in terms of the ulcer size and depth. To analyze and compare the data, frequency distribution, mean (standard deviation), variance analysis, and the independent samples t test and the χ test were used. The mean ulcer areas were 12.63 (14.43), 6.91 (5.44), 4.30 (3.70), and 3.29 (3.80) cm (P diabetic foot ulcer sizes in the study intervention group in the 4th and 12th weeks compared to beginning baseline (P ≤ .05). However, only the 12th week was different from the beginning in the control group (P = .000). The mean depths of the ulcers were 0.56 (0.85), 0.42 (0.68), 0.36 (0.50), and 0.28 (0.38) cm in the study intervention group (P foot exercises should be included in the treatment plan when managing patients with diabetic foot ulcers.

  4. Foot placement strategy in pushing and pulling.

    Science.gov (United States)

    Lee, Tzu-Hsien

    2018-01-01

    Pushing and pulling tasks are very common in daily and industrial workplaces. They are one major source of musculoskeletal complaints. This study aimed to examine the foot placement strategy while pushing and pulling. Thirteen young males and ten young females were recruited as participants. A two (pushing and pulling) by four (48 cm, 84 cm, 120 cm, and 156 cm) factorial design was used. Exertion direction and exertion height significantly affected foot placement strategy. Pushing task needed more anteroposterior space than pulling task. The percentages of female/male for trailing foot position ranged from 77% to 90% (pushing) and from 80% to 93% (pulling) across the exertion heights. Practitioners should provide an anteroposterior space approximately to 70% body stature for workers to exert their maximum pulling and pushing strengths.

  5. Depression and incident diabetic foot ulcers: a prospective cohort study

    Science.gov (United States)

    Williams, Lisa H.; Rutter, Carolyn M.; Katon, Wayne J.; Reiber, Gayle E.; Ciechanowski, Paul; Heckbert, Susan R.; Lin, Elizabeth H.B.; Ludman, Evette J.; Oliver, Malia M.; Young, Bessie A.; Von Korff, Michael

    2010-01-01

    Objective To test whether depression is associated with an increased risk of incident diabetic foot ulcers. Methods The Pathways Epidemiologic Study is a population-based prospective cohort study of 4839 patients with diabetes in 2000–2007. The present analysis included 3474 adults with type 2 diabetes and no prior diabetic foot ulcers or amputations. Mean follow-up was 4.1 years. Major and minor depression assessed by the Patient Health Questionnaire-9 (PHQ-9) were the exposures of interest. The outcome of interest was incident diabetic foot ulcers. We computed the hazard ratio (HR) and 95% CI for incident diabetic foot ulcers, comparing patients with major and minor depression to those without depression and adjusting for sociodemographic characteristics, medical comorbidity, glycosylated hemoglobin (HbA1c), diabetes duration, insulin use, number of diabetes complications, body mass index, smoking status, and foot self-care. Sensitivity analyses also adjusted for peripheral neuropathy and peripheral arterial disease as defined by diagnosis codes. Results Compared to patients without depression, patients with major depression by PHQ-9 had a two-fold increase in the risk of incident diabetic foot ulcers (adjusted HR 2.00, 95% CI: 1.24, 3.25). There was no statistically significant association between minor depression by PHQ-9 and incident diabetic foot ulcers (adjusted HR 1.37, 95% CI: 0.77, 2.44). Conclusion Major depression by PHQ-9 is associated with a two-fold higher risk of incident diabetic foot ulcers. Future studies of this association should include better measures of peripheral neuropathy and peripheral arterial disease, which are possible confounders and/or mediators. PMID:20670730

  6. Evaluation of "care of the foot" as a risk factor for diabetic foot ulceration: the role of internal physicians.

    Science.gov (United States)

    Oguejiofor, O C; Oli, J M; Odenigbo, C U

    2009-03-01

    Several risk factors predispose the diabetic patient to foot ulceration, including "inadequate care of the foot". This risk factor for foot ulceration has not been previously evaluated among Nigeria diabetic patients and is the objective of this study. One hundred and twenty (120) diabetic patients with and without symptoms of peripheral neuropathy receiving care at the medical outpatient department (MOPD) and the diabetic clinic of the Nnamdi Azikiwe University Teaching Hospital Nnewi were recruited consecutively as they presented. They were administered structured questionnaires to assess some variables concerning care of their feet as provided to them by their physicians. Among the 120 diabetic participants, 83 (69.2%) had neuropathic symptoms (the symptomatic participants) while 37 (30.8%) were asymptomatic (the asymptomatic participants). Eighty (80; 96.4%) of the symptomatic vs 36 (97.3%) of the asymptomatic participants had never had their feet examined by their physician. Also, 26 (31.3%) of the symptomatic vs 12 (32.4%) of the asymptomatic participants had never received any form of advice on how to take special care of their feet by their physician, and 26 (31.3%) of the symptomatic vs 6 (16.2%) of the asymptomatic participants walked unshod most times in their immediate surroundings. Physicians do not provide adequate care to the feet of their diabetic patients irrespective of the presence or absence of neuropathic symptoms, making this variable a critical risk factor for diabetic foot ulceration and amputation. Continuing medical education to health care providers emphasizing adequate "care of the foot" of the diabetic patient, will reduce avoidable loss of limbs to diabetes.

  7. Electrowetting-on-dielectrics for manipulation of oil drops and gas bubbles in aqueous-shell compound drops.

    Science.gov (United States)

    Li, Jiang; Wang, Yixuan; Chen, Haosheng; Wan, Jiandi

    2014-11-21

    We present the manipulation of oil, organic and gaseous chemicals by electrowetting-on-dielectric (EWOD) technology using aqueous-shell compound drops. We demonstrate that the transport and coalescence of viscous oil drops, the reaction of bromine with styrene in benzene solution, and the reaction of red blood cells with carbon monoxide bubbles can be accomplished using this method.

  8. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  9. Prospective study of ankle and foot fractures in elderly women

    Directory of Open Access Journals (Sweden)

    Yadagiri Surender Rao

    2015-01-01

    Full Text Available The epidemiology of ankle fractures in old people is changing as time passes on. The incidence of ankle fractures increases with advancing age. The study conducted was among a rural popula-tion which comprised of 68 women (32 women with ankle fractures & 36 women with foot fractures. Patients studied were in the age group more than 50 years. The study highlights the etiological & risk factors for fractures of ankle & foot. The commonest ankle fracture was the lateral malleolar fracture & the commonest foot fracture was the 5th Metatarsal fracture. Diabetes is a risk factor which increases the occurrence of ankle and foot injuries.

  10. Selective dorsal rhizotomy opportunities with foot deformitiesin children with cerebral palsy

    Directory of Open Access Journals (Sweden)

    Vladimir Markovich Kenis

    2015-03-01

    Full Text Available Foot deformities are the most common orthopedic condition in children with cerebral palsy. The aim of the study was to evaluate the influence of selective dorsal rhizotomy (SDR on foot deformities in children with cerebral palsy. The results were assessed clinically by measurement of changes in muscle spaticity and foot posture. Percentage of resection of dorsal rootlets was from 40 to 90 % of total thickness. The degree of tone reduction had a tendency to be more pronounced in the more proximal muscles and was minimal in calf muscles. Nevertheless, foot posture improved more significantly. That can be explained by generalimprovement of pathological posture at the level of more proximal joints. Thus, SDR has insignificant direct effect on spastic foot deformity and can not be recommended as a basic method of treatment even in pure spasticity. However, SDR should be considered as a part of multidisciplinary management protocol if foot deformity reflects more complex postural disturbance due to generalized spasticity.

  11. Touch-less interaction with medical images using hand & foot gestures

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Smith, Jeremiah; Sousa, Miguel

    2013-01-01

    control. In this paper, we present a system for gesture-based interaction with medical images based on a single wristband sensor and capacitive floor sensors, allowing for hand and foot gesture input. The first limited evaluation of the system showed an acceptable level of accuracy for 12 different hand...... & foot gestures; also users found that our combined hand and foot based gestures are intuitive for providing input....

  12. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    Science.gov (United States)

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  13. Studying the field induced breakup of acoustically levitated drops

    Science.gov (United States)

    Warschat, C.; Riedel, J.

    2017-10-01

    Coulomb fission of charged droplets (The terms drop and droplet are often used synonymous. Throughout this manuscript, to avoid confusion, the terms drop and droplet will be used for liquid spheres with radii in the millimeter range and the micrometer range, respectively. In our experiments, the first correspond to the parent drop while the latter describes the ejected progeny droplets.) is a well-studied natural phenomenon. Controlled droplet fission is already successfully employed in several technological applications. Still, since the occurring surface rupture relies on the exact understanding and description of the liquid gas boundary, some details are still under debate. Most empirical systematic studies observe falling micrometer droplets passing through the electric field inside a plate capacitor. This approach, although easily applicable and reliable, limits the experimental degrees of freedom regarding the observable time and the maximum size of the drops and can only be performed in consecutive individual observations of different subsequent drops. Here we present a novel setup to study the field induced breakup of acoustically levitated drops. The design does not bear any restrictions towards the temporal window of observation, and allows handling of drops of a tunable radius ranging from 10 μm to several millimeters and a real-time monitoring of one single drop. Our comprehensive study includes a time resolved visual inspection, laser shadowgraphy, laser induced fluorescence imaging, and ambient mass spectrometric interrogation of the nascent Taylor cone. The results shown for a millimeter sized drop, previously inaccessible for Coulomb fission experiments, are mostly comparable with previous results for smaller drops. The major difference is the time scale and the threshold potential of the drop rupture. Both values, however, resemble theoretically extrapolations to the larger radius. The technique allows for a systematic study of breakup behavior of

  14. Motion of a drop driven by substrate vibrations

    Science.gov (United States)

    Brunet, P.; Eggers, J.; Deegan, R. D.

    2009-01-01

    We report an experimental study of liquid drops moving against gravity, when placed on a vertically vibrating inclined plate, which is partially wet by the drop. Frequency of vibrations ranges from 30 to 200 Hz, and above a threshold in vibration acceleration, drops experience an upward motion. We attribute this surprising motion to the deformations of the drop, as a consequence of an up/down symmetry-breaking induced by the presence of the substrate. We relate the direction of motion to contact angle measurements.

  15. Postoperative infection in the foot and ankle.

    LENUS (Irish Health Repository)

    Chan, Victoria O

    2012-07-01

    Our discussion highlights the commonly performed surgical procedures in the foot and ankle and reviews the various imaging modalities available for the detection of infection with graphic examples to better enable radiologists to approach the radiological evaluation of postoperative infection in the foot and ankle. Discrimination between infectious and noninfectious inflammation remains a diagnostic challenge usually needing a combination of clinical assessment, laboratory investigations, and imaging studies to increase diagnostic accuracy.

  16. The new Drop Tower catapult system

    Science.gov (United States)

    von Kampen, Peter; Kaczmarczik, Ulrich; Rath, Hans J.

    2006-07-01

    The Center of Applied Space Technology and Microgravity (ZARM) was founded in 1985 as an institute of the University Bremen, which focuses on research on gravitational and space-related phenomena. In 1988, the construction of the "Drop Tower" began. Since then, the eye-catching tower with a height of 146 m and its characteristic glass roof has become the emblem of the technology centre in Bremen. The Drop Tower Bremen provides a facility for experiments under conditions of weightlessness. Items are considered weightless, when they are in "free fall", i.e. moving without propulsion within the gravity field of the earth. The height of the tower limits the simple "free fall" experiment period to max. 4.74 s. With the inauguration of the catapult system in December 2004, the ZARM is entering a new dimension. This world novelty will meet scientists' demands of extending the experiment period up to 9.5 s. Since turning the first sod on May 3rd, 1988, the later installation of the catapult system has been taken into account by building the necessary chamber under the tower. The catapult system is located in a chamber 10 m below the base of the tower. This chamber is almost completely occupied by 12 huge pressure tanks. These tanks are placed around the elongation of the vacuum chamber of the drop tube. In its centre there is the pneumatic piston that accelerates the drop capsule by the pressure difference between the vacuum inside the drop tube and the pressure inside the tanks. The acceleration level is adjusted by means of a servo hydraulic breaking system controlling the piston velocity. After only a quarter of a second the drop capsule achieves its lift-off speed of 175 km/h. With this exact speed, the capsule will rise up to the top of the tower and afterwards fall down again into the deceleration unit which has been moved under the drop tube in the meantime. The scientific advantages of the doubled experiment time are obvious: during almost 10 s of high

  17. Effects of non-implantation factors on survival rate of microbe irradiated by low-energy N+

    International Nuclear Information System (INIS)

    Yang Tianyou; Chen Linhai; Qin Guangyong; Li Zongwei; Su Mingjie; Wang Yanping; Chang Shenghe; Huo Yuping; Li Zongyi

    2006-01-01

    The effects of non-implantation factors, such as drying, vacuum and the staying time of the E.coli LE392 culture, on survival rate of E.coli LE392 were studied when E.coli LE392 was irradiated by the low-energy N + . The results show that the survival rate of E.coli LE392 does not reduce steadily all the time but rapidly drops sometime during drying. The survival rate of E.coli LE392 declines sharply as the samples are placed in vacuum, then falls in distinctively with increasing of time. the tolerance of E.coli LE392 towards vacuum increasingly strengthens when the E.coli LE392 culture is placed at room temperature. Preparing the culture in batchs can ensure the consistency of the irradiated samples and avoid errors caused by the inconsistent samples. When the non-implantation factors are controlled, E.coli is implanted by 30 kev N + of 1 x 10 14 cm -2 and 3 x 10 15 cm -2 , respectively. And the results show no difference in the E.coli's survival rates between batchs at the same dose. (authors)

  18. Implant Restoration of Edentulous Jaws with 3D Software Planning, Guided Surgery, Immediate Loading, and CAD-CAM Full Arch Frameworks

    Directory of Open Access Journals (Sweden)

    Silvio Mario Meloni

    2013-01-01

    Full Text Available Purpose. The aim of this study was to analyze the clinical and radiographic outcomes of 23 edentulous jaws treated with 3D software planning, guided surgery, and immediate loading and restored with CAD-CAM full arch frameworks. Materials and Methods. This work was designed as a prospective case series clinical study. Twenty patients have been consecutively rehabilitated with an immediately loaded implant supported fixed full prosthesis. A total of 120 fixtures supporting 23 bridges were placed. 117 out of 120 implants were immediately loaded. Outcome measures were implants survival, radiographic marginal bone levels and remodeling, soft tissue parameters, and complications. Results. 114 of 117 implants reached a 30 months follow-up, and no patients dropped out from the study. The cumulative survival rate was 97.7%; after 30 months, mean marginal bone level was  mm, mean marginal bone remodeling value was , mean PPD value was  mm, and mean BOP value was 4% ± 2.8%. Only minor prosthetic complications were recorded. Conclusion. Within the limitations of this study, it can be concluded that computer-guided surgery and immediate loading seem to represent a viable option for the immediate rehabilitations of completely edentulous jaws with fixed implant supported restorations. This trial is registered with Clinicaltrials.gov NCT01866696.

  19. Theory of magnetostriction of electron-hole drops in Ge

    International Nuclear Information System (INIS)

    Markiewicz, R.S.

    1978-01-01

    A large mass of electron-hole liquid (γ drop) formed in a strain-induced potential well in Ge is known to distort its shape significantly in a magnetic field B > or approx. = 1 kG. It is shown in this paper that the shape change can be understood in detail as due to a ''recombination current'' of electron-hole pairs needed to replace those pairs which recombine in the drop volume. The Lorentz force deflects this current and produces a macroscopic dipole current loop inside the drop. The drop then changes shape to minimize its total energy, including magnetic, strain, and surface energies. While the drop usually flattens along the field direction, both para- and diamagnetic effects (elongated drops) are found to be possible, depending on excitation conditions, in accord with experiment. Similar effects are predicted to occur in small drops in unstrained Ge. This paper presents a magnetohydrodynamic theory of the magnetostriction which takes into account density variations which occur in the strain well and in high magnetic fields. A simpler theory is given for the special case in which the drop may be considered incompressible (small drops and moderate fields). Effects of carrier mass anisotropy and fluid viscosity are taken into consideration

  20. Ground Motion Prediction Equations Empowered by Stress Drop Measurement

    Science.gov (United States)

    Miyake, H.; Oth, A.

    2015-12-01

    Significant variation of stress drop is a crucial issue for ground motion prediction equations and probabilistic seismic hazard assessment, since only a few ground motion prediction equations take into account stress drop. In addition to average and sigma studies of stress drop and ground motion prediction equations (e.g., Cotton et al., 2013; Baltay and Hanks, 2014), we explore 1-to-1 relationship for each earthquake between stress drop and between-event residual of a ground motion prediction equation. We used the stress drop dataset of Oth (2013) for Japanese crustal earthquakes ranging 0.1 to 100 MPa and K-NET/KiK-net ground motion dataset against for several ground motion prediction equations with volcanic front treatment. Between-event residuals for ground accelerations and velocities are generally coincident with stress drop, as investigated by seismic intensity measures of Oth et al. (2015). Moreover, we found faster attenuation of ground acceleration and velocities for large stress drop events for the similar fault distance range and focal depth. It may suggest an alternative parameterization of stress drop to control attenuation distance rate for ground motion prediction equations. We also investigate 1-to-1 relationship and sigma for regional/national-scale stress drop variation and current national-scale ground motion equations.