WorldWideScience

Sample records for acrysof toric intraocular

  1. LIO pseudofácica suplementar sulcoflex® toric sobre LIO acrysof® toric

    Directory of Open Access Journals (Sweden)

    Hilton Arcoverde Gonçalves de Medeiros

    2013-10-01

    Full Text Available Para correção de alta hipermetropia e astigmatismo irregular secundário a múltiplas cirurgias refrativas em uma mulher de 45 anos, foi utilizada a sutura das incisões radiais, com implante de lente intraocular (LIO Acrysof® Toric. Para correção do residual de erro refracional, foi implantada LIO pseudofácica tórica suplementar sobre LIO Primária. A acuidade visual (AV inicial era de LogMAR 0,9 e a final de LogMAR 0,3. O implante da LIO suplementar tórica sobre LIO tórica primária mostrou-se uma boa opção, proporcionando melhora da acuidade visual.

  2. Toric Intraocular Lens Outcomes in Patients With Glaucoma.

    Science.gov (United States)

    Brown, Reay H; Zhong, Le; Bozeman, Caroline W; Lynch, Mary G

    2015-06-01

    To report the outcomes of toric intraocular lens implantation in patients with glaucoma and corneal astigmatism. One hundred twenty-six eyes of 87 patients with glaucoma and corneal astigmatism that underwent cataract surgery with an AcrySof toric intraocular lens (Alcon Laboratories, Inc., Fort Worth, TX) implant were selected for this single-center, retrospective case series. Corrected distance visual acuity, intraocular pressure, and refractive astigmatism were measured in each eye preoperatively and postoperatively. Uncorrected distance visual acuity and toric alignment were measured postoperatively. The uncorrected distance visual acuity was 0.04 ± 0.08 logMAR (20/22 Snellen) for all eyes. Ninety-eight percent of all eyes achieved an uncorrected distance visual acuity of 20/40 or better, with 76% achieving 20/25 or better and 47% achieving 20/20. The corrected distance visual acuity for all eyes was 0.01 ± 0.03 logMAR (20/20.5 Snellen) postoperatively. The refractive cylinder improved from 1.47 ± 1.10 diopters preoperatively to 0.31 ± 0.37 diopters postoperatively. The residual refractive cylinder was 1.00 diopter or less in 97% of eyes, 0.75 diopters or less in 90% of eyes, and 0.50 diopters or less in 83% of eyes. Mean misalignment was 4.4° ± 5.1°. Intraocular pressure decreased by a mean of 2.3 ± 3.3 mm Hg following the surgery. Toric intraocular lenses can reliably reduce astigmatism and improve uncorrected vision in eyes with cataract and glaucoma. Copyright 2015, SLACK Incorporated.

  3. Evaluation of rotation and visual outcomes after implantation of monofocal and multifocal toric intraocular lenses.

    Science.gov (United States)

    Garzón, Nuria; Poyales, Francisco; de Zárate, Begoña Ortíz; Ruiz-García, Jose Luis; Quiroga, Juan Antonio

    2015-02-01

    To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin, Germany], enVista [Bausch & Lomb, Rochester, NY], and AcrySof IQ [Alcon Laboratories, Inc., Fort Worth, TX]) and one multifocal toric IOL (AcrySof IQ ReSTOR; Alcon Laboratories, Inc.) were implanted. Preoperative and postoperative images were taken to calculate the misalignment due to the marking method. To evaluate rotation in the different follow-up visits, another photograph was taken 1 hour and 1, 7 and 30 days postoperatively. Refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity were measured 30 days postoperatively. Postoperative UDVA was 0.1 logMAR or better in 64.6% of eyes implanted with monofocal IOLs and 46.4% of eyes implanted with multifocal IOLs. The enVista toric IOL showed the best UDVA compared to the other monofocal IOLs, with 81% of eyes with 0.1 logMAR or better. The mean misalignment in the total group studied was 0.07° ± 0.60°; 69.6% of monofocal IOLs and 67.9% of multifocal IOLs showed less than 5° of rotation. A correlation was found between postoperative UDVA and rotation in the monofocal and multifocal IOLs implanted (r = 0.439 [P < .011] and = 0.787 [P = .001], respectively). At 1 month postoperatively, UDVA was slightly more affected by IOL rotation in multifocal than monofocal toric IOLs. The marking method was also effective. Copyright 2015, SLACK Incorporated.

  4. Comparison of clinical outcomes between limbal relaxing incisions and toric intraocular lenses in eyes with astigmatic corneas

    Directory of Open Access Journals (Sweden)

    Giuliano de Oliveira Freitas

    2014-01-01

    Full Text Available Objective: To compare refractive and vectorial outcomes of limbal relaxing incisions (LRI versus toric intraocular lenses (IOL in the treatment of preexisting corneal astigmatism at the time of phacoemulsification. Methods: This longitudinal observational case series assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism between 0.75 and 2.50 diopters in both eyes. Patients were randomly assorted in two groups: one assigned to receive AcrySof Toric™ IOL in both eyes, and another one assigned to have AcrySof Natural™ IOL associated with LRI, also in both eyes. All patients were re-evaluated, postoperatively, at 1, 3 and 6 months, when refractive astigmatism analysis was performed using vectorial methods proposed by Thibos. Variability of outcomes within each group and between groups were assessed and compared. Results: Manifest refractive cylinder, in diopters (D, as means ± standard deviation, in the LRI group for 1-month, 3-month and 6-month re-evalutions were respectively -0.66 ± 0.30; -0.70 ± 0.21 and -0.74 ± 0.26 when compared to -0.58 ± 0.24; -0.63 ± 0.20, and -0.62 ± 0.17 in the toric IOL group. (p value ≥ 0.06. Vectorial analysis evidenced greater astigmatism reduction in the toric IOL group in the 6th postoperative month, when postoperative mean astigmatic power vector was 0.31 D, when compared to 0.37 D in the LRI group (p value = 0.00. Conclusions: A trend of slightly better refractive outcomes favoring toric IOL group was seen, although such a trend was not statistically significant. Vectorial analysis, however, suggests that the use of toric IOL may constitute a more advantageous approach in the treatment of pre-existing corneal astigmatism, simultaneously with phacoemulsification.

  5. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.

    Science.gov (United States)

    Webers, Valentijn S C; Bauer, Noel J C; Visser, Nienke; Berendschot, Tos T J M; van den Biggelaar, Frank J H M; Nuijts, Rudy M M A

    2017-06-01

    To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. University Eye Clinic Maastricht, Maastricht, the Netherlands. Prospective randomized clinical trial. Eyes with regular corneal astigmatism of at least 1.25 diopters (D) that required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T9) were randomly assigned to the image-guided group or the manual-marking group. The primary outcome was the alignment of the toric IOL based on preoperative images and images taken immediately after surgery. Secondary outcome measures were residual astigmatism, uncorrected distance visual acuity (UDVA), and complications. The study enrolled 36 eyes (24 patients). The mean toric IOL misalignment was significantly less in the image-guided group than in the manual group 1 hour (1.3 degrees ± 1.6 [SD] versus 2.8 ± 1.8 degrees; P = .02) and 3 months (1.7 ± 1.5 degrees versus 3.1 ± 2.1 degrees; P image-guided group and manual group, respectively (P > .05). The mean UDVA was 0.03 ± 0.10 logarithm of minimum angle of resolution (logMAR) and 0.04 ± 0.09 logMAR, respectively (both P > .05). No intraoperative complications occurred during any surgery. The IOL misalignment was significantly less with digital marking than with manual marking; this did not result in a better UDVA or lower residual refractive astigmatism. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Does the apodized diffractive intraocular lens Acrysof ReSTOR NaturalTM interfere with FDT Matrix perimetry results? A lente difrativa apodizada Acrysof ReSTOR NaturalTM pode interferir nos resultados da perimetria por FDT Matrix?

    Directory of Open Access Journals (Sweden)

    Karine Duarte Bojikian

    2009-12-01

    Full Text Available PURPOSE: To compare the effect of an apodized diffractive intraocular lens (IOL (Acrysof ReSTOR NaturalTM and its yellow counterpart (Natural IQ TM on frequency doubling technology (FDT perimetry results. METHODS: This study included 37 eyes from 22 patients at the "Centro Oftalmológico Tranjan" who had undergone uncomplicated phacoemulsification and intraocular lens implantation (17 Acrysof ReSTOR NaturalTM, 20 Natural IQ TM performed by the same surgeon, at least three months prior to the study. Patients were subject to frequency doubling technology Matrix Perimeter testing. RESULTS: The patients were between 41 to 79 years old (mean, 70.78 ± 9.83 in the Natural IQ TM and 49 to 81 years old (mean, 67.11± 11.48 in the Acrysof ReSTOR NaturalTM group, and the mean IOP was 13.64 ± 2.02 mmHg in the Natural IQ TM 12.94 ± 1.39 mmHg in the Acrysof ReSTOR NaturalTM group. The mean pupillary diameter under scotopic conditions was 6.63 ± 1.16 mm in the Natural IQ TM group and 7.20 ± 1.8 mm in the Acrysof ReSTOR NaturalTM group (p=0.20. The mean deviation was -1.83 ± 3.46 dB in the Natural IQ TM group and -1.77 ± 3.94 dB in the Acrysof ReSTOR NaturalTM group (p=0.28. The pattern standard deviation was 3.49 ± 0.79 dB in the Natural IQ TM group and 3.20 ± 0.86 dB in the Acrysof ReSTOR NaturalTM group (p=0.27. CONCLUSION: There was no difference in the results of FDT Matrix perimetry in eyes that received apodized diffractive IOLs implant or eyes that received monofocal intraocular lens implant.OBJETIVO: Comparar o efeito da lente difrativa apodizada (Acrysof ReSTOR NaturalTM e da lente de mesma plataforma amarela (Natural IQ TM sobre os resultados da perimetria de dupla frequência (FDT. MÉTODOS: O estudo incluiu 37 olhos de 22 pacientes do Centro Oftalmológico Tranjan que foram submetidos a cirurgia de facoemulsificação e implante de lentes intraoculares (17 Acrysof ReSTOR NaturalTM, 20 Natural IQ TM sem complicações, realizadas pelo mesmo

  7. Clinical assessment of diclofenac sodium eye drops in toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yan Luo

    2013-05-01

    Full Text Available AIM:To evaluate the application of diclofenac sodium eye drops in toric intraocular lens implantation. METHODS: From January 2011 to February 2012, 38 eyes of 37 patients, who underwent toric intraocular lens implantation in this hospital, were randomly divided into diclofenac sodium eye drops group(trial groupand control group. Patient's degree of cooperation during surgery and inflammation postoperation after 1 day, 3,7, days, 1 month and 3 months were evaluated. RESULTS: Patient's degree of cooperation during surgery in the trial group(1.53±0.62was significantly better than in the control group(2.40±0.88, P<0.05. Inflammation reaction was gentle in the trial group 1 day postoperatively. CONCLUSION: Diclofenac sodium eye drops used during toric intraocular lens implantation can obviously alleviate eye irritation, and increase the cooperation of patients.

  8. Functional and refractive results after one month of AcrySof toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Francisco Alba-Bueno

    2011-04-01

    Conclusions: The implantation of SN60T toric IOL in patients with CA higher than 0.75 D is a safe, predictable and effective way of reducing refractive astigmatism in patients undergoing cataract surgery.

  9. Computerized calculation scheme for toric intraocular lenses.

    Science.gov (United States)

    Langenbucher, Achim; Seitz, Berthold

    2004-06-01

    While a number of intraocular lens (IOL) power prediction formulae are well established for determination of spherical lenses, no common strategy has been published for the computation of toric IOLs. The purpose of this study is to describe a paraxial computing scheme for tracing an axial pencil of rays through the 'optical system eye' containing astigmatic refractive surfaces with their axes at random. The capabilities of this computing scheme are demonstrated with clinical examples. Based on a schematic model eye with spherocylindric surfaces, we use two alternative notations for description of vergences or prescriptions: (1) standard notation (refraction in both cardinal meridians and axis), and (2) component notation (spherical equivalent and cylindric component in 0 degrees and 45 degrees. Refractive surfaces are added to the vergence in component notation, whereas the transformation of the vergence through media is performed in the standard notation for both cardinal meridians. For calculation of the toric lens implant, a pencil of rays is traced through the spectacle and the cornea to the estimated lens position as well as backwards from the retina to the estimated lens position. For calculation of residual spectacle refraction, a pencil of rays is traced backwards from the retina through the toric lens implant and the cornea to the spectacle plane. In example 1 we calculate a 'thin toric lens' for compensation of a corneal astigmatism to achieve a spherical target refraction. In example 2 we compute a 'thick toric lens', which has to compensate for an oblique corneal astigmatism and rotate the spectacle cylinder to the against the rule position to enhance near vision. In example 3 we estimate the residual refraction at the corneal plane after implantation of a thick toric lens, when the cylinder of the lens implant is compensating the corneal cylinder in part and the axis of implantation is not fully aligned with the axis of the corneal astigmatism. This

  10. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Tendal, Britta

    2016-01-01

    TOPIC: We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were...

  11. Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

    Directory of Open Access Journals (Sweden)

    Aditya Kelkar

    2015-07-01

    Full Text Available Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases.

  12. Comparison between OPD-scan results and contrast sensitivity of three intraocular lenses: spheric AcrySof SN60AT, aspheric AcrySof SN60WF and multifocal AcrySof Restor lens Estudo comparativo da análise de frente de onda e sensibilidade ao contraste entre as lentes intra-oculares multifocal AcrySof Restor SN60D3, monofocal AcrySof SN60WF asférica e a monofocal SN60AT esférica

    Directory of Open Access Journals (Sweden)

    Celso Takashi Nakano

    2009-08-01

    ção com implantes de lentes intraoculares AcrySof SN60D3 multifocal, AcrySof SN60WF monofocal asférica e AcrySof SA60AT monofocal esférica. Métodos: Trinta e dois olhos com a lente intraocular multifocal, 32 olhos com a lente intraocular monofocal asférica e 32 olhos com a lente intraocular monofocal esférica. A avaliação oftalmológica foi realizada no primeiro, terceiro, sétimo, e nonagésimo dia pós-operatório. Todos os exames foram padronizados, realizada por um único examinador sob condições controladas de luminosidade fotópicas estabelecidas em 85 cd/m², medida por meio de tabelas de ETDRS, sensibilidade ao contraste e análise de aberrometria com OPD-Scan. Resultados: As médias de aberração total foi superior no grupo SN60AT (KW = 9.42; p=0.009 quando comparada com o grupo SN60D3 (p=0.016 e o grupo SN60WF (p=0.0047. O grupo SN60AT (KW = 16.20; p=0.0003 apresentou superioridade nas medias de aberração esférica comparada com o grupo SN60WF (p=0.00046 e o grupo SN60D3 (p=0.0014. Nenhuma diferença significante foi encontrada na acuidade visual para longe com e sem correção óptica com a tabela de ETDRS a 100% e 9% de contraste. O grupo SN60D3 comparada a SN60AT (p=0.016 apresentou baixa sensibilidade ao contraste em condições fotópicas com diferença estatística a 6.0 cpg (KW = 7.84; p=0.0199, mas sem diferença estatística entre os grupos SN60WF e SN60AT (p=0.91 e entre os grupos SN60WF e SN60D3 (p=0.051. O grupo SN60D3 apresentou baixa sensibilidade ao contraste em condições mesópicas (KW = 10.79; p=0,0045 a 6cpg quando comparada com o grupos SN60AT (p=0.011 e SN60WF (p=0.007. Conclusão: As lentes intraoculares multifocais e asféricas apresentaram menos aberração esférica quando comparadas à lente intraocular esférica, além da prevista multifocalidade sem correção para longe e perto. Entretanto, o grupo multifocal apresentou baixa sensibilidade ao contraste.

  13. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery

    NARCIS (Netherlands)

    Webers, V.S.C.; Bauer, N.J.C.; Visser, N.; Berendschot, T.T.J.M.; van den Biggelaar, F.J.H.M.; Nuijts, R.M.M.A.

    2017-01-01

    Purpose To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. Setting University Eye Clinic Maastricht, Maastricht, the Netherlands. Design Prospective randomized clinical trial. Methods Eyes with

  14. Toric intraocular lens implantation versus astigmatic keratotomy to correct astigmatism during phacoemulsification.

    Science.gov (United States)

    Titiyal, Jeewan S; Khatik, Mukesh; Sharma, Namrata; Sehra, Sri Vatsa; Maharana, Parfulla K; Ghatak, Urmimala; Agarwal, Tushar; Khokhar, Sudarshan; Chawla, Bhavana

    2014-05-01

    To compare toric intraocular lens (IOL) implantation and astigmatic keratotomy (AK) in correction of astigmatism during phacoemulsification. Tertiary care hospital. Prospective randomized trial. Consecutive patients with visually significant cataract and moderate astigmatism (1.25 to 3.00 diopters [D]) were randomized into 2 groups. Temporal clear corneal 2.75 mm phacoemulsification with toric IOL implantation was performed in the toric IOL group and with 30-degree coupled AK at the 7.0 mm optic zone in the keratotomy group. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, keratometry, topography, central corneal thickness, and endothelial cell density were evaluated preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. The study enrolled 34 eyes (34 patients), 17 in each group. There was no difference in UDVA or CDVA between the 2 groups at any follow-up visit. The mean preoperative and postoperative refractive cylinder was 2.00 D ± 0.49 (SD) and 0.33 ± 0.17 D, respectively, in the toric IOL group and 1.95 ± 0.47 D and 0.57 ± 0.41 D, respectively, in the keratotomy group (P=.10). The mean residual astigmatism at 3 months was 0.44 ± 1.89 @ 160 in the toric IOL group and 0.77 ± 1.92 @ 174 in the keratotomy group (P=.61). All eyes in the toric IOL group and 14 eyes (84%) in the keratotomy group achieved a residual refractive cylinder of 1.00 D or less (P=.17). Toric IOL implantation was comparable to AK in eyes with moderate astigmatism having phacoemulsification. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. [Hyperopic Laser-in-situ-Keratomileusis after trifocal intraocular lens implantation : Aberration-free femto-Laser-in-situ-Keratomileusis treatment after implantation of a diffractive, multifocal, toric intraocular lens-case analysis].

    Science.gov (United States)

    Hemkeppler, E; Böhm, M; Kohnen, T

    2018-05-29

    A 52-year-old highly myopic female patient was implanted with a multifocal, diffractive, toric intraocular lens because of the wish to be independent of eyeglasses. Despite high-quality, extensive preoperative examinations, a hyperopic refractive error remained postoperatively, which led to the patient's dissatisfaction. This error was treated with Laser-in-situ-Keratomileusis (LASIK). After corneal LASIK treatment and implantation of a diffractive toric multifocal intraocular lens the patient showed a good postoperative visual result without optical phenomena.

  16. Modelling lifetime cost consequences of toric compared with standard IOLs in cataract surgery of astigmatic patients in four European countries.

    Science.gov (United States)

    Laurendeau, C; Lafuma, A; Berdeaux, G

    2009-09-01

    To compare the lifetime costs of freeing astigmatic patients from spectacles after bilateral cataract surgery implanting toric intraocular lenses (IOLs: i.e., Acrysof Toric) versus monofocal IOLs, in France, Italy, Germany and Spain. A Markov model followed patient cohorts from cataract surgery until death. Prevalence rates of patients not needing spectacles and the types of spectacles prescribed for those requiring them were obtained from clinical trials and national surveys. The economic perspective was societal. Mortality rates were incorporated into the model. Discount rates were applied. A sensitivity analysis was performed on non-discounted costs. Fewer patients with toric IOLs needed spectacles for distance vision than patients with monofocal IOLs. With monofocal IOLs more than 66% of patients needed complex spectacles compared to less than 25% implanted with toric IOLs. In France and Italy, toric IOLs reduced overall costs relative to otherwise high spectacle costs after cataract surgery. Savings were 897.0 euros (France), 822.5 euros (Germany), 895.8 euros (Italy) and 391.6 euros (Spain), without discounting. On applying a 3% discount rate the costs became 691.7 euros, 646.4 euros, 693.9 euros and 308.2 euros, respectively. Bilateral toric IOL implants in astigmatic patients decreased spectacle dependence for distance vision and the need for complex spectacles. The economic consequences for patients depended on the national spectacle costs usually incurred after cataract surgery.

  17. Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system: Influence of pupil size, decentration, and rotation.

    Science.gov (United States)

    Kim, Min-Ji; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2015-10-01

    To evaluate the effect of pupil size, degree of intraocular lens (IOL) decentration, and rotation of 4 aspheric toric IOLs on the image quality. Department of Ophthalmology, Seoul St. Mary's Hospital, Seoul, South Korea. Experimental study. Four aspheric toric intraocular lenses (IOLs)-the Precizon (transitional conic toric IOL), AT Torbi 709M (bitoric IOL), SN6AT4 (posterior toric surface IOL), and ZCT225 (anterior toric surface IOL)-were evaluated using the optical bench metrology system. Measurements included changes in spherical aberrations, relative spherical equivalent (SE), and image quality at different pupil diameters and image quality degradation due to decentration and rotation of the IOLs. Change in relative SE with pupil size in aberration-free toric IOLs (transitional conic toric and bitoric IOLs) was greater than in negatively aspheric toric IOLs (posterior toric surface and anterior toric surface IOLs). In contrast, the aberration-free IOLs showed higher contrast than the negatively aspheric IOLs. When IOLs were decentered by 1.0 mm, the contrast reduction rates at 17.6 cycles per degree for the transitional conic toric IOL, bitoric IOL, posterior toric surface IOL, and anterior toric surface IOL were 5.1%, 3.1%, 12.2%, and 15.8%, respectively. Rotation-induced deterioration of contrast to 0.5 required a much higher rotation for the transitional conic toric IOL than for the other 3 IOLs. The transitional conic toric IOL and bitoric IOL provided superior image quality despite pupil size changes and the presence of decentration. The transitional conic toric IOL demonstrated maximum rotation tolerance compared with the other IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Customized toric intraocular lens implantation for correction of extreme corneal astigmatism due to corneal scarring

    Directory of Open Access Journals (Sweden)

    R Bassily

    2010-03-01

    Full Text Available R Bassily, J LuckOphthalmology Department, Royal United Hospital, Combe Park, Bath, UKAbstract: A 76-year-old woman presented with decreased visual function due to cataract formation. Twenty-five years prior she developed right sided corneal ulceration that left her with 10.8 diopters (D of irregular astigmatism at 71.8° (steep axis. Her uncorrected visual acuity was 6/24 and could only ever wear a balanced lens due to the high cylindrical error. Cataract surgery was planned with a custom designed toric intraocular lens (IOL with +16.0 D sphere inserted via a wound at the steep axis of corneal astigmatism. Postoperative refraction was -0.75/+1.50 × 177° with a visual acuity of 6/9 that has remained unchanged at six-week follow-up with no IOL rotation. This case demonstrates the value of high power toric IOLs for the correction of pathological corneal astigmatism.Keywords: intraocular lens, corneal ulceration, visual acuity, scarring

  19. Comparison of visual function and patient satisfaction with AcrySof ReSTORSN6AD1 multifocal intraocular compared to monofocal intraocular lenses 5

    Directory of Open Access Journals (Sweden)

    Aisa S Alchinova

    2016-12-01

    Full Text Available Aim. To compare visual function and satisfaction in patients after implantation of AcrySof ReSTOR SN6AD1 multifocal intraocular lens (IOL, AcrySof SA60AТ spherical monofocal IOL, or Akreos АО aspheric monofocal IOL during cataract surgery. Materials. Overall, 34 patients received SN6AD1 multifocal (group 1, 48 eyes, 19 patients received Akreos АО monofocal aspheric (group 2, 30 eyes, and 13 patients received AcrySof SA60AТ monofocal spherical (group 3, 18 eyes IOL. Patients with multifocal IOL were closely matched for age, sex, and ocular findings with patients who had monofocal IOL implantation. Six months postoperatively, uncorrected/corrected distance visual acuity (UDVA/CDVA, uncorrected intermediate (60 cm and near (35 cm visual acuity (UNVA, defocus curve, contrast sensitivity, and a quality-of-life questionnaire were evaluated. Furthermore, independence from glasses and presence of optical phenomena were assessed. Results. Patients in group 2 had statistically significant increase in UDVA than that in group 1 (p = 0.037. There was no significant difference in the mean uncorrected intermediate and best corrected distance visual acuities between the groups. UNVA was better in group 1 than that in groups 2 and 3 (p < 0.0001. Photopic contrast sensitivity for high spatial frequencies was better in groups 2 and 3. Glare was reported in 5.9% of patients in group 1. Halos occurred in 32.4% of patients in group 1. No one reported undesirable visual symptoms in groups 2 and 3. Conclusion. Multifocal IOLs provided higher spectacle independence and satisfactory functional vision over a broad range of distances but were associated with increased subjective visual symptoms and reduced photopic contrast sensitivity for high spatial frequencies and distance visual quality compared with monofocal IOLs.

  20. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  1. Correction of High Astigmatism after Penetrating Keratoplasty with Toric Multifocal Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-07-01

    Full Text Available After penetrating keratoplasty (PK, high astigmatism is often induced, being frequently about 4–6 dpt. According to the entity and typology of astigmatism, different methods of correction can be used. Selective suture removal, relaxing incisions, wedge resections, compression sutures, photorefractive keratectomy, and laser-assisted in situ keratomileusis can reduce corneal astigmatism and ametropia, but meanwhile they can cause a reduction in the corneal integrity and cause an over- or undercorrection. In case of moderate-to-high regular astigmatisms, the authors propose a toric multifocal intraocular lens (IOL implantation to preserve the corneal integrity (especially in PK after herpetic corneal leukoma keratitis. We evaluated a 45-year-old patient who at the age of 30 was subjected to PK in his left eye due to corneal leukoma herpetic keratitis, which led to high astigmatism (7.50 dpt cyl. 5°. The patient was subjected to phacoemulsification and customized toric multifocal IOL implantation in his left eye. The correction of PK-induced residual astigmatism with a toric IOL implantation is an excellent choice but has to be evaluated in relation to patient age, corneal integrity, longevity graft, and surgical risk. It seems to be a well-tolerated therapeutic choice and with good results.

  2. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  3. Pupil Influence on the Visual Outcomes of a New-Generation Multifocal Toric Intraocular Lens With a Surface-Embedded Near Segment.

    Science.gov (United States)

    Wang, Mengmeng; Corpuz, Christine Carole C; Huseynova, Tukezban; Tomita, Minoru

    2016-02-01

    To evaluate the influences of preoperative pupil parameters on the visual outcomes of a new-generation multifocal toric intraocular lens (IOL) model with a surface-embedded near segment. In this prospective study, patients with cataract had phacoemulsification and implantation of Lentis Mplus toric LU-313 30TY IOLs (Oculentis GmbH, Berlin, Germany). The visual and optical outcomes were measured and compared preoperatively and postoperatively. The correlations between preoperative pupil parameters (diameter and decentration) and 3-month postoperative visual outcomes were evaluated using the Spearman's rank-order correlation coefficient (Rs) for the nonparametric data. A total of 27 eyes (16 patients) were enrolled into the current study. Statistically significant improvements in visual and refractive performances were found after the implantation of Lentis Mplus toric LU-313 30TY IOLs (P 0; P .05). Lentis Mplus toric LU-313 30TY IOLs provided excellent visual and optical performances during the 3-month follow-up. The preoperative pupil size is an important parameter when this toric multifocal IOL model is contemplated for surgery. Copyright 2016, SLACK Incorporated.

  4. Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring.

    Science.gov (United States)

    Rastogi, Anju; Khanam, Samreen; Goel, Yashpal; Thacker, Prolima; Kumar, Prateek

    2018-03-01

    To evaluate the rotational stability of toric intraocular lens (IOL) when co-implanted with a capsular tension ring (CTR) as compared to that of a toric IOL without a CTR. This was a prospective randomized clinical trial performed in a tertiary care centre in India. Fifty adult human eyes with visually significant cataract and regular corneal astigmatism ≥1.5D divided into two groups of 25 eyes each, A and B by simple randomization. Eyes with corneal pathology, lens subluxation, and a specular endothelial cell count IOL. In Group A, a CTR was put in the bag before IOL implantation. The groups were called for follow-up on day 1, 1 week, 1 month, and 3 months, postoperatively. The axis of the toric IOL on each visit was measured by slit lamp imaging in retroillumination and analyzed digitally. Mean rotation of toric IOL at 3 months postoperatively was 1.85 ± 1.72° in Group A and 4.02 ± 2.04° in Group B. The difference was statistically significant (P = 0.003). Coimplantation of a CTR is a safe and effective technique for ensuring better rotational stability of toric IOLs.

  5. Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring

    Directory of Open Access Journals (Sweden)

    Anju Rastogi

    2018-01-01

    Full Text Available Purpose: To evaluate the rotational stability of toric intraocular lens (IOL when co-implanted with a capsular tension ring (CTR as compared to that of a toric IOL without a CTR. Methods: This was a prospective randomized clinical trial performed in a tertiary care centre in India. Fifty adult human eyes with visually significant cataract and regular corneal astigmatism ≥1.5D divided into two groups of 25 eyes each, A and B by simple randomization. Eyes with corneal pathology, lens subluxation, and a specular endothelial cell count <2000/mm2 were excluded from the study. The eyes in both the groups underwent standard phacoemulsification and were implanted with a toric IOL. In Group A, a CTR was put in the bag before IOL implantation. The groups were called for follow-up on day 1, 1 week, 1 month, and 3 months, postoperatively. The axis of the toric IOL on each visit was measured by slit lamp imaging in retroillumination and analyzed digitally. Results: Mean rotation of toric IOL at 3 months postoperatively was 1.85 ± 1.72° in Group A and 4.02 ± 2.04° in Group B. The difference was statistically significant (P = 0.003. Conclusion: Coimplantation of a CTR is a safe and effective technique for ensuring better rotational stability of toric IOLs.

  6. Bilateral implantation of +3.0 D multifocal toric intraocular lenses: results of a US Food and Drug Administration clinical trial.

    Science.gov (United States)

    Lehmann, Robert; Modi, Satish; Fisher, Bret; Michna, Magda; Snyder, Michael

    2017-01-01

    The purpose of this study was to evaluate the clinical outcomes of apodized diffractive +3.0 D multifocal toric intraocular lens (IOL) implantations in subjects with preoperative corneal astigmatism. This was a prospective cohort study conducted at 21 US sites. The study population consisted of 574 subjects, aged ≥21 years, with preoperative astigmatism 0.75-2.82 D, and potential postoperative visual acuity (VA) ≥0.2 logMAR, undergoing bilateral cataract removal by phacoemulsification. The intervention was bilateral implantation of aspheric apodized diffractive +3.0 D multifocal toric or spherical multifocal nontoric IOLs. The main outcome measures were monocular uncorrected near and distance VA and safety at 12 months. A total of 373/386 and 182/188 subjects implanted with multifocal toric and nontoric IOLs, respectively, completed 12-month follow-up after the second implantation. Toric IOLs were nonin-ferior in monocular uncorrected distance (4 m) and near (40 cm) VA but had >1 line better binocular uncorrected intermediate VA (50, 60, and 70 cm) than nontoric IOLs. Toric IOLs reduced cylinder to within 0.50 D and 1.0 D of target in 278 (74.5%) and 351 (94.1%) subjects, respectively. Mean ± standard deviation (SD) differences between intended and achieved axis orientation in the first and second implanted eyes were 5.0°±6.1° and 4.7°±4.0°, respectively. Mean ± SD 12-month IOL rotations in the first and second implanted eyes were 2.7°±5.8° and 2.2°±2.7°, respectively. No subject receiving toric IOLs required secondary surgical intervention due to optical lens properties. Multifocal toric IOLs were noninferior to multifocal nontoric IOLs in uncorrected distance and near VAs in subjects with preexisting corneal astigmatism and effectively corrected astigmatism of 0.75-2.82 D.

  7. Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Wojciech Lubiński

    2016-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with implantation of the Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive, and keratometric outcomes as well as IOL rotation were evaluated during a 6-month follow-up. At the end of the follow-up, patient satisfaction and perception of optical/visual disturbances were also evaluated using a subjective questionnaire. Results. At 6 months after surgery, mean LogMAR uncorrected (UDVA and corrected distance visual acuity (CDVA were 0.19±0.12 and 0.14±0.10, respectively. Postoperative UDVA of 20/40 or better was achieved in 92.6% of eyes. Mean refractive cylinder decreased significantly from −3.73±1.96 to −1.42±0.88 D (p<0.001, while keratometric cylinder did not change significantly (p=0.44. Mean absolute IOL rotation was 1.1±2.4°, with values of more than 5° in only 2 eyes (6.9%. Mean patient satisfaction score was 9.70±0.46, using a scale from 0 (not at all satisfied to 10 (very satisfied. No postoperative optical/visual disturbances were reported. Conclusion. Cataract surgery with implantation of the Tecnis toric IOL is an effective method of refractive correction in eyes with corneal astigmatism due to the good IOL positional stability, providing high levels of patient’s satisfaction.

  8. Visual and Refractive Outcomes after Cataract Surgery with Implantation of a New Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Cinzia Mazzini

    2013-06-01

    Full Text Available Purpose: The aim of this study was to evaluate and report the visual, refractive and aberrometric outcomes of cataract surgery with implantation of the new aspheric Tecnis ZCT toric intraocular lens (IOL in eyes with low to moderate corneal astigmatism. Methods: We conducted a prospective study of 19 consecutive eyes of 17 patients (mean age: 78 years with a visually significant cataract and moderate corneal astigmatism [higher than 1 diopter (D] undergoing cataract surgery with implantation of the aspheric Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive and aberrometric changes were evaluated during a 6-month follow-up. Ocular aberrations as well as IOL rotation were evaluated by means of the OPD-Station II (Nidek. Results: The six-month postoperative spherical equivalent and power vector components of the refractive cylinder were within ±0.50 D in all eyes (100%. Postoperative logMAR uncorrected and corrected distance visual acuities (UDVA/CDVA were 0.1 (about 20/25 or better in almost all eyes (94.74%. The mean logMAR CDVA improved significantly from 0.41 ± 0.23 to 0.02 ± 0.05 (p Conclusion: Cataract surgery with implantation of the aspheric Tecnis ZCT IOL is a predictable and effective procedure for visual rehabilitation in eyes with cataract and low to moderate corneal astigmatism, providing an excellent postoperative ocular optical quality.

  9. A comparison of visual outcomes in three different types of monofocal intraocular lenses.

    Science.gov (United States)

    Shetty, Vijay; Haldipurkar, Suhas S; Gore, Rujuta; Dhamankar, Rita; Paik, Anirban; Setia, Maninder Singh

    2015-01-01

    To compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens). The present study is a cross-sectional analysis of secondary clinical data collected from 153 eyes (52 eyes in Matrix Aurium, 48 in AcrySof single piece, and 53 in AcrySof IQ group) undergoing cataract surgery (2011-2012). We compared near vision, distance vision, distance corrected near vision in these three types of lenses on day 15 (±3) post-surgery. About 69% of the eyes in the Matrix Aurium group had good uncorrected distance vision post-surgery; the proportion was 48% and 57% in the AcrySof single piece and AcrySof IQ group (P=0.09). The proportion of eyes with good distance corrected near vision were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). Similarly, The proportion with good "both near and distance vision" were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). It was only the Matrix Aurium group which had significantly better both "distance and near vision" compared with the AcrySof IQ group (odds ratio: 5.87, 95% confidence intervals: 1.68 to 20.56). Matrix Aurium monofocal lenses may be a good option for those patients who desire to have a good near as well as distance vision post-surgery.

  10. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

    Science.gov (United States)

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms

    2018-01-01

    To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

  11. Implantation of a Multifocal Toric Intraocular Lens after Radial Keratotomy and Cross-Linking with Hyperopia and Astigmatism Residues: A Case Report

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-08-01

    Full Text Available Radial keratotomy is a refractive surgical technique, widely used in the 80s and early 90s to correct myopia and astigmatism, but now overcome by more recent laser techniques. Important consequences, often in patients with more than 45 years of age, are progressive hyperopic shift and/or an increase in corneal astigmatism, whose main cause seems to be an increase in the curvature radius of the central portion of the cornea. This seems to be due to radial keratotomy incisions – with the consequent need for cross-linking – intraocular pressure, and corneal biomechanical parameters. The authors propose phacoemulsification with a customized multifocal toric intraocular lens implantation to correct the induced shift and hyperopic astigmatism. A decent postoperative visual acuity was observed with good patient satisfaction. A specific protocol must be applied to optimize the correct diagnosis, presurgical evaluation and postsurgical outcomes that are to be maintained over time, without regressions.

  12. Combined special capsular tension ring and toric IOL implantation for management of post-DALK high regular astigmatism with subluxated traumatic cataract

    Directory of Open Access Journals (Sweden)

    Asim Kumar Kandar

    2014-01-01

    Full Text Available We report a case of 18-year-old male who has undergone phacoemulsification with implantation of toric IOL (AcrySof IQ SN6AT9 after fixation of lens capsule with Cionni′s capsular tension ring (CTR for subluxated traumatic cataract with high astigmatism after deep anterior lamellar keratoplasty (DALK. He underwent right eye DALK for advanced keratoconus four years earlier. He had history of trauma one year later with displaced clear crystalline lens into  anterior chamber and graft dehiscence, which was repaired successfully. The graft survived, but patient developed cataract with subluxated lens, for which phacoemulsification with implantation of toric IOL was done. Serial  topography showed regular corneal astigmatism of -5.50 diopter (K 1 42.75 D @130°, K 2 48.25 D @40°. At 10-month follow-up, the patient has BCVA 20/30 with + 0.75 DS/- 1.75 DC @ 110°. The capsular bag is quite stable with well-centered IOL. Combination of Cionni′s ring with toric IOL could be a good option to manage such complex cases.

  13. Combined special capsular tension ring and toric IOL implantation for management of post-DALK high regular astigmatism with subluxated traumatic cataract.

    Science.gov (United States)

    Kandar, Asim Kumar

    2014-07-01

    We report a case of 18-year-old male who has undergone phacoemulsification with implantation of toric IOL (AcrySof IQ SN6AT9) after fixation of lens capsule with Cionni's capsular tension ring (CTR) for subluxated traumatic cataract with high astigmatism after deep anterior lamellar keratoplasty (DALK). He underwent right eye DALK for advanced keratoconus four years earlier. He had history of trauma one year later with displaced clear crystalline lens into  anterior chamber and graft dehiscence, which was repaired successfully. The graft survived, but patient developed cataract with subluxated lens, for which phacoemulsification with implantation of toric IOL was done. Serial  topography showed regular corneal astigmatism of -5.50 diopter (K 1 42.75 D @130°, K 2 48.25 D @40°). At 10-month follow-up, the patient has BCVA 20/30 with + 0.75 DS/- 1.75 DC @ 110°. The capsular bag is quite stable with well-centered IOL. Combination of Cionni's ring with toric IOL could be a good option to manage such complex cases.

  14. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

    Science.gov (United States)

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant ( P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° ( P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° ( P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  15. Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Talita Shimoda

    2014-04-01

    Full Text Available Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC was -2.19 (SD: ± 0.53. After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001. Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.

  16. Contrast visual acuity after multifocal intraocular lens implantation:aspheric versus spherical design

    Directory of Open Access Journals (Sweden)

    Jun-Hua Li

    2014-02-01

    Full Text Available AIM: To evaluate contrast visual acuity (CVA after implantation of an aspheric apodized diffractive intraocular lens (IOL or a spherical apodized diffractive IOL in cataract surgery.METHOD: This prospective randomized controlled study with a 12-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL (30 eyes and a spherical AcrySof ReSTOR SN60D3 IOL (30 eyes. CVA with best distance correction was measured at 4 contrast levels (100%, 25%, 10% and 5% under 3 levels of chart luminance [250, 85 and 25 candelas per square meter (cd/m2] using a multi-functional visual acuity tester (MFVA-100.RESULTS:At 12 months after surgery, there were no statistically significant differences in 100% CVA and 25% CVA under 250cd/m2 (P100%=0.875 and P25%=0.057 and 85cd/m2 (P100%=0.198 and P25%=0.193 between the aspheric group and the spherical group. However, the 10% CVA and 5% CVA were significant better in aspheric group than spherical group under 250cd/m2 (P10%=0.042 and P5%=0.007 and 85cd/m2 (P10%=0.002 and P5%=0.039. Under the luminance level of 25cd/m2, no significant differences was found in the 100% CVA between the 2 group (P100%=0.245, while aspheric group had better visual acuity in the remaining 3 contracts (P25%=0.023, P10%=0.026 and P5%=0.002, respectively.CONCULSION:The aspheric AcrySof ReSTOR SN6AD3 IOL provided patients with better low-contrast visual acuity than the spherical AcrySof ReSTOR SN60D3 IOL.Keyword:cataract surgery; intraocular lens; contrast sensitivity; visual acuity

  17. Toric Vaisman manifolds

    Science.gov (United States)

    Pilca, Mihaela

    2016-09-01

    Vaisman manifolds are strongly related to Kähler and Sasaki geometry. In this paper we introduce toric Vaisman structures and show that this relationship still holds in the toric context. It is known that the so-called minimal covering of a Vaisman manifold is the Riemannian cone over a Sasaki manifold. We show that if a complete Vaisman manifold is toric, then the associated Sasaki manifold is also toric. Conversely, a toric complete Sasaki manifold, whose Kähler cone is equipped with an appropriate compatible action, gives rise to a toric Vaisman manifold. In the special case of a strongly regular compact Vaisman manifold, we show that it is toric if and only if the corresponding Kähler quotient is toric.

  18. Pigment dispersion and chronic intraocular pressure elevation after sulcus placement of 3-piece acrylic intraocular lens.

    Science.gov (United States)

    Almond, M Camille; Wu, Michael C; Chen, Philip P

    2009-12-01

    A 55-year-old man had phacoemulsification and implantation of a 3-piece acrylic intraocular lens (IOL) (AcrySof MA60AC) in the right eye. One month postoperatively, the intraocular pressure (IOP) was 48 mm Hg and peripheral transillumination defects were noted in the iris circumferentially, with the IOL optic edge visible as a silhouette. Gonioscopy showed dense pigmentation of the trabecular meshwork in the right eye, but in the left eye, only mild trabecular meshwork pigment was seen, along with a concave peripheral iris insertion. At 21 months, the right eye required 3 medications for IOP control. While pigment dispersion has been widely reported after placement of 1-piece acrylic IOLs in the ciliary sulcus, we conclude that in susceptible individuals with a concave peripheral iris insertion, pigment dispersion can occur with sulcus placement of a 3-piece acrylic model despite its thinner optic and angulated haptics.

  19. Toric implantable collamer lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Mathew Kurian Kummelil

    2013-01-01

    Full Text Available Keratoconus is a progressive non-inflammatory thinning of the cornea that induces myopia and irregular astigmatism and decreases the quality of vision due to monocular diplopia, halos, or ghost images. Keratoconus patients unfit for corneal procedures and intolerant to refractive correction by spectacles or contact lenses have been implanted toric posterior chamber phakic intraocular lenses (PC pIOLs alone or combined with other surgical procedures to correct the refractive errors associated with keratoconus as an off label procedure with special informed consent from the patients. Several reports attest to the safety and efficacy of the procedure, though the associated corneal higher order aberrations would have an impact on the final visual quality.

  20. Implantation of a multifocal toric intraocular lens with a surface-embedded near segment after repeated LASIK treatments.

    Science.gov (United States)

    Khoramnia, Ramin; Auffarth, Gerd U; Rabsilber, Tanja M; Holzer, Mike P

    2012-11-01

    We report a 66-year-old patient who presented with increasing hyperopia, astigmatism, and presbyopia in both eyes 8 years after bilateral laser in situ keratomileusis (LASIK) and LASIK enhancement in the left eye aiming for spectacle independence. Bilateral multifocal toric Lentis Mplus intraocular lenses (IOLs) with an embedded near segment and individually customized cylinder correction were implanted uneventfully following phacoemulsification. The Haigis-L formula after previous hyperopia correction was chosen for IOL power calculation and provided reliable results. Emmetropia was targeted and achieved. Three months postoperatively, the uncorrected distance visual acuity had increased from 0.40 logMAR to 0.10 logMAR in the right eye and from 0.20 logMAR to 0.00 logMAR in the left eye. The patient gained 6 lines of uncorrected near visual acuity: 0.20 logMAR in the right eye and 0.10 logMAR in the left eye. This case shows that customized premium IOL implantation can provide accurate results even in challenging cases. The International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany, has received research grants, lecture fees, and travel reimbursement from Oculentis GmbH. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Toric topology

    CERN Document Server

    Buchstaber, Victor M

    2015-01-01

    This book is about toric topology, a new area of mathematics that emerged at the end of the 1990s on the border of equivariant topology, algebraic and symplectic geometry, combinatorics, and commutative algebra. It has quickly grown into a very active area with many links to other areas of mathematics, and continues to attract experts from different fields. The key players in toric topology are moment-angle manifolds, a class of manifolds with torus actions defined in combinatorial terms. Construction of moment-angle manifolds relates to combinatorial geometry and algebraic geometry of toric v

  2. In vivo chromatic aberration in eyes implanted with intraocular lenses.

    Science.gov (United States)

    Pérez-Merino, Pablo; Dorronsoro, Carlos; Llorente, Lourdes; Durán, Sonia; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2013-04-12

    To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL). EIGHTEEN EYES PARTICIPATED IN THIS STUDY: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine implanted with AcrySof SN60WF IOL. A custom-developed laser ray tracing (LRT) aberrometer was used to measure the optical aberrations, at 532 nm and 785 nm wavelengths. The monochromatic wave aberrations were described using a fifth-order Zernike polynomial expansion. The chromatic difference of focus was estimated as the difference between the equivalent spherical errors corresponding to each wavelength. Wave aberration measurements were highly reproducible. Except for the defocus term, no significant differences in high order aberrations (HOA) were found between wavelengths. The average chromatic difference of focus was 0.46 ± 0.15 diopters (D) in the Tecnis group, and 0.75 ± 0.12 D in the AcrySof group, and the difference was statistically significant (P Chromatic difference of focus in the AcrySof group was not statistically significantly different from the Longitudinal chromatic aberration (LCA) previously reported in a phakic population (0.78 ± 0.16 D). The impact of LCA on retinal image quality (measured in terms of Strehl ratio) was drastically reduced when considering HOA and astigmatism in comparison with a diffraction-limited eye, yielding the differences in retinal image quality between Tecnis and AcrySof IOLs not significant. LRT aberrometry at different wavelengths is a reproducible technique to evaluate the chromatic difference of focus objectively in eyes implanted with IOLs. Replacement of the crystalline lens by the IOL did not increase chromatic difference of focus above that of phakic eyes in any of the groups. The AcrySof group showed chromatic difference of focus values very similar to physiological values in

  3. Intraocular lens power selection and positioning with and without intraoperative aberrometry.

    Science.gov (United States)

    Hatch, Kathryn M; Woodcock, Emily C; Talamo, Jonathan H

    2015-04-01

    To determine the value of intraoperative aberrometry in cases of toric intraocular lens (IOL) implantation and positioning. In this non-randomized retrospective comparative trial, two groups of eyes underwent cataract extraction with toric IOL implantation: the aberrometry group (n = 37 eyes), where toric IOL power and alignment were determined before surgery with automated keratometry, standard optical biometry, and an online calculator and then refined using intraoperative aberrometry, and the toric calculator group (n = 27 eyes), where IOL selection was performed in a similar manner but without intraoperative aberrometry. The primary outcome measure was mean postoperative residual refractive astigmatism (RRA). Mean RRA measured at follow-up after surgery was 0.46 ± 0.42 and 0.68 ± 0.34 diopters (D) in the aberrometry and toric calculator groups, respectively (P = .0153). A 75% and 57% reduction in cylinder was noted between preoperative keratometric astigmatism and postoperative RRA in the aberrometry and toric calculator groups, respectively (P = .0027). RRA of 0.25 D or less, 0.50 D or less, 0.75 D or less, and 1.00 D or less was seen 38%, 78%, 86%, and 95% of the time, respectively, in the aberrometry group and 22%, 33%, 74%, and 89% of the time, respectively, in the toric calculator group. These data show that the chance of a patient being in a lower postoperative RRA range increased when intraoperative aberrometry was used (P = .0130). Patients undergoing cataract extraction with toric IOL placement aided by intraoperative aberrometry were 2.4 times more likely to have less than 0.50 D of RRA compared to standard methods. Copyright 2015, SLACK Incorporated.

  4. Avaliação da sensibilidade ao contraste e da estereopsia em pacientes com lente intra-ocular multifocal Contrast sensitivity and stereopsis in pseudophakic patients with multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Filipe de Oliveira

    2005-08-01

    Full Text Available OBJETIVO: Avaliar a sensibilidade ao contraste e a acuidade estereoscópica em pacientes pseudofácicos, que receberam implante bilateral de lente intra-ocular multifocal. MÉTODOS: Prospectivamente foram realizados testes de sensibilidade ao contraste com o uso da tabela Pelli-Robson e teste de acuidade estereoscópica com emprego do Titmus Stereo Test, em 20 pacientes com implante bilateral de lente intra-ocular multifocal Acrysof Restor®, no pós-operatório de 1 a 2 meses e sem uso de qualquer correção óptica. RESULTADOS:O teste de sensibilidade ao contraste binocular demonstrou que 6 pacientes (30% apresentaram 1,80 unid. log, 13 (65% 1,65 e 1 (5% 1,50. No teste monocular, ocorreram as seguintes respostas: 17 pacientes (85% 1,65 unid. log e 3 (15% 1,50 para o teste do olho direito. O teste do olho esquerdo mostrou que 16 pacientes (80% apresentaram 1,65 unid. log e 4 (20% 1,50. A média e o desvio-padrão da sensibilidade ao contraste testada binocularmente foi 1,69 (±0,08, ao passo que monocularmente foi 1,63 (±0,05 para OD e 1,62 (±0,06 para OE. O teste de acuidade estereoscópica revelou que 12 pacientes (60% obtiveram 40", 6 (30% 50" e 2 (10% 60", com média de 45" e desvio-padrão de ±6,88". CONCLUSÃO: A lente intra-ocular empregada no estudo, proporcionou resultados de sensibilidade ao contraste e acuidade estereoscópica compatíveis e de acordo com critérios de normalidade estabelecidos anteriormente por outros estudos em grupos de pacientes fácicos e pseudofácicos, e portanto, impacto positivo na funcionalidade visual.PURPOSE: To evaluate the contrast sensitivity and stereopsis tests in patients who underwent bilateral implantation of multifocal intraocular lens. METHODS: Tests of contrast sensitivity using the Pelli-Robson chart and stereopsis evaluation with the Titmus Stereo Test were performed in 20 patients 30-60 days after the bilateral implantation of Acrysof Restor® multifocal intraocular lens. RESULTS: The

  5. Comparison between OPD-Scan results and visual outcomes of monofocal and multifocal intraocular lenses Comparação dos resultados do OPD-Scan e performance visual das lentes intraoculares monofocal e multifocal

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2009-08-01

    Full Text Available PURPOSE: To compare the visual outcome, contrast sensitivity and wavefront analysis of patients that underwent cataract surgery and implantation of AcrySof SN60D3 multifocal intraocular lens with those who received the AcrySof SN60AT monofocal IOL. METHODS: This was a prospective clinical trial of forty eyes that received the multifocal IOL and thirty-two eyes that received the monofocal IOL after phacoemulsification. RESULTS: Values for total and spherical aberrations in the multifocal group were statistically lower than in the monofocal group. In the monofocal group, 75% achieved uncorrected intermediate visual acuities between Jaeger 1 and 6. In the multifocal group, 75% of the eyes achieved more than Jaeger 6. At least 87.5% of the multifocal group and 6.3% of the monofocal group achieved monocular uncorrected near acuity of 20/30 (J2, N5 or better. And 90.0% of the eyes in the multifocal group and 37.5% in the monofocal group achieved an uncorrected near acuity of 20/40 (J3, N6 or better. The mean spherical error was 0.11 D in the multifocal group and -0.18 D in the monofocal group (p=0.0379. The SN60D3 group compared to SN60AT group had low contrast sensitivity (log units with statistically significant differences in 6.0 cpd in photopic conditions (p=0.014 and the SN60D3 group compared to SN60AT group had higher contrast sensitivity (log units under mesopic conditions (p=0.044. CONCLUSION: The multifocal IOLs induced less spherical aberration than monofocal IOLs and predictably good uncorrected distance and uncorrected near acuities. However, contrast sensitivity was lower in the multifocal group.OBJETIVO: Comparar a performance visual, sensibilidade ao contraste e de wavefront com OPD-Scan em pacientes submetidos a cirurgia de facoemulsificação com implante de lente intraocular AcrySof SN60D3 multifocal e AcrySof SA60AT monofocal. MÉTODOS: Quarenta olhos com a lente intraocular multifocal e trinta e dois olhos com a lente intraocular

  6. Combinatorial construction of toric residues

    OpenAIRE

    Khetan, Amit; Soprounov, Ivan

    2004-01-01

    The toric residue is a map depending on n+1 semi-ample divisors on a complete toric variety of dimension n. It appears in a variety of contexts such as sparse polynomial systems, mirror symmetry, and GKZ hypergeometric functions. In this paper we investigate the problem of finding an explicit element whose toric residue is equal to one. Such an element is shown to exist if and only if the associated polytopes are essential. We reduce the problem to finding a collection of partitions of the la...

  7. Software-based evaluation of toric IOL orientation in a multicenter clinical study.

    Science.gov (United States)

    Kasthurirangan, Sanjeev; Feuchter, Lucas; Smith, Pamela; Nixon, Donald

    2014-12-01

    To evaluate the rotational stability of a new one-piece hydrophobic acrylic toric intraocular lens (IOL) using a custom-developed software for analysis of slit-lamp photographs. In a prospective, multicenter study, 174 eyes were implanted with the TECNIS Toric IOL (Abbott Medical Optics, Inc., Santa Ana, CA). A custom-developed software was used to analyze high-resolution slit-lamp photographs of 156 eyes taken at day 1 (baseline) and 1, 3, and 6 months postoperatively. The software uses iris and sclera landmarks to align the baseline image and later images for comparison. Validation of software was performed through repeated analyses of protractor images rotated from 0.1° to 10.0° and randomly selected photographs of 20 eyes. Software validation showed precision (repeatability plus reproducibility variation) of 0.02° using protractor images and 2.22° using slit-lamp photographs. Good quality slit-lamp images and clear landmarks were necessary for precise measurements. At 6 months, 94.2% of eyes had 5° or less change in IOL orientation versus baseline; only 2 eyes (1.4%) had axis shift greater than 30°. Most eyes were within 5° or less of rotation between 1 and 3 months (92.9%) and 3 and 6 months (94.1%). Mean absolute axis change (± standard deviation) from 1 day to 6 months was 2.70° ± 5.51°. The new custom software was precise and quick in analyzing slit-lamp photographs to determine postoperative toric IOL rotation. Copyright 2014, SLACK Incorporated.

  8. Desempenho visual dos pacientes pseudofácicos com diferentes lentes intraoculares

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2013-10-01

    Full Text Available OBJETIVO: Comparar a performance visual dos pacientes submetidos ao implante das lentes intraoculares multifocais difrativas Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60WF e Acrysof® SN60AT. MÉTODOS: Estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata, provenientes do ambulatório de oftalmologia do HC-FMUSP. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste, pupilometria e análise de frente de onda por meio do aberrômetro. Todos os exames foram realizados com seis meses de pós-operatório. RESULTADOS: A média de idade dos pacientes foi de 60,7±6,6 anos no grupo Tecnis, 63,1±4,4 anos no grupo Restor e 63,7±4,2 anos no grupo monofocal (SN60AT no olho contralateral SN60WF. A acuidade visual para perto não corrigida e corrigida para longe foi estatisticamente superior nos grupos multifocal Restor e multifocal Tecnis em comparação ao grupo monofocal SN60AT/SN60WF (p<0,001. Não houve diferença estatística entre os grupos na comparação da acuidade visual para longe (p=0,56. A sensibilidade ao contraste fotópica monocular foi estatisticamente inferior nos grupos Restor e Tecnis (p<0,001. A SN60AT apresentou maior aberração esférica comparada a todas as outras lentes (p<0,001. A Tecnis se mostrou com menores valores médios de aberrações esféricas na comparação com a Restor (p<0.001. CONCLUSÃO: A Restor e Tecnis apresentaram melhor acuidade visual para perto do que o grupo monofocal SN60AT/SN60WF. Todas as lentes intraoculares promoveram boa visão para longe. O grupo da Tecnis apresentou melhor sensibilidade de contraste, menos aberrações ópticas e melhor visão intermediária que o grupo Restor.

  9. Frobenius splitting of projective toric bundles

    Indian Academy of Sciences (India)

    He Xin

    2018-03-19

    Mar 19, 2018 ... Firstly it is easy to see that the image of s under the restriction map (2.5) falls in the χ-isotypical component of (Uσ , E), i.e. for all t ∈ T .... σ falls in the χ-isotypical component of (E,Uσ ). D. As mentioned in Remark 2.3, for a vector v .... The determinant of a toric bundle. LetE be a toric bundle on a toric variety X ...

  10. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Vilar C

    2017-08-01

    Full Text Available César Vilar,1,2 Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 Klayny Rafaella Pereira Magalhães,2 Patrick Frensel de Moraes Tzelikis,1,2 Mario Augusto Pereira Dias Chaves,2,4 Antônio Francisco Pimenta Motta,2,3 Pedro Carlos Carricondo,1–3 Milton Ruiz Alves,3 Walton Nosé5 1Cataract Division, Brasília Ophthalmologic Hospital (HOB, Brasília-DF, Brazil; 2Renato Ambrosio Ophthalmologic Research Center (CEORA, 3Ophthalmology Department, São Paulo University – USP, São Paulo-SP, Brazil; 4Cataract Division, ProVisão, João Pessoa-PB, Brazil; 5Ophthalmology Department, Paulista Medical School – UNIFESP, São Paulo-SP, Brazil Purpose: To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye.Methods: This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA and uncorrected intermediate (60 cm and near (at 40 cm visual acuity; contrast sensitivity (CS and visual defocus curve.Results: Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision.Conclusion: Both lens combinations were able to provide good near, intermediate and distance vision

  11. Visual function after implantation of single-piece toric hydrophilic acrylic intraocular lenses with hydrophobic surface six months after cataract surgery

    Directory of Open Access Journals (Sweden)

    Alja Črnej

    2012-06-01

    Conclusion: Patients with medium to high corneal astigmatism and implanted single-piece toric hydrophilic acrylic IOLs with hydrophobic surface have very good visual function six months postoperatively.

  12. Toric Codes, Multiplicative Structure and Decoding

    DEFF Research Database (Denmark)

    Hansen, Johan Peder

    2017-01-01

    Long linear codes constructed from toric varieties over finite fields, their multiplicative structure and decoding. The main theme is the inherent multiplicative structure on toric codes. The multiplicative structure allows for \\emph{decoding}, resembling the decoding of Reed-Solomon codes and al...

  13. c-Extremization from toric geometry

    Science.gov (United States)

    Amariti, Antonio; Cassia, Luca; Penati, Silvia

    2018-04-01

    We derive a geometric formulation of the 2d central charge cr from infinite families of 4d N = 1 superconformal field theories topologically twisted on constant curvature Riemann surfaces. They correspond to toric quiver gauge theories and are associated to D3 branes probing five dimensional Sasaki-Einstein geometries in the AdS/CFT correspondence. We show that cr can be expressed in terms of the areas of the toric diagram describing the moduli space of the 4d theory, both for toric geometries with smooth and singular horizons. We also study the relation between a-maximization in 4d and c-extremization in 2d, giving further evidences of the mixing of the baryonic symmetries with the exact R-current in two dimensions.

  14. Mapping spaces and automorphism groups of toric noncommutative spaces

    Science.gov (United States)

    Barnes, Gwendolyn E.; Schenkel, Alexander; Szabo, Richard J.

    2017-09-01

    We develop a sheaf theory approach to toric noncommutative geometry which allows us to formalize the concept of mapping spaces between two toric noncommutative spaces. As an application, we study the `internalized' automorphism group of a toric noncommutative space and show that its Lie algebra has an elementary description in terms of braided derivations.

  15. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  16. Instrumental studies on silicone oil adsorption to the surface of intraocular lenses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chun Ho [Lab. of Tissue Engineering, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of); Joo, Choun-Ki [Department of Ophthalmology and Visual Science, Medical College of Catholic University, Seoul 137-701 (Korea, Republic of); Chun, Heung Jae, E-mail: chunhj@catholic.ac.kr [Institute of Cell and Tissue Engineering, Medical College of Catholic University, Seoul 137-701 (Korea, Republic of); Yoo, Bok Ryul [Organosilicone Chemistry Laboratory, Korea Institute of Science and Technology, Seoul 130-650 (Korea, Republic of); Noh, Dong Il; Shim, Young Bock [Research Institute of Biomedical Engineering, Korea Bone Bank Co. Ltd., Seoul 153-782 (Korea, Republic of)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer It was found that PHEMA and Acrysof IOLs possess silicone oil repellant ability. Black-Right-Pointing-Pointer The residual silicone oil was detected on the surfaces of PMMA and silicone IOLs. Black-Right-Pointing-Pointer XPS studies showed that silicone oil coverage of PMMA lenses was 12%. Black-Right-Pointing-Pointer Silicone oil covered the entire surface of the silicone IOLs. - Abstract: The purpose of this study was to examine the degree of adherence of silicone oil to various intraocular lenses (IOLs) through comparison of the physico-chemical properties of the oil and IOLs. Four kinds of IOLs comprising various biomaterials were examined: PMMA (720A Trade-Mark-Sign ), PHEMA (IOGEL 1103 Trade-Mark-Sign ), Acrysof (MA60BM Trade-Mark-Sign ), and silicone (SI30NB Trade-Mark-Sign ). Each lens was immersed in silicone oil or carboxylated silicone (CS-PDMS) oil for 72 h. For determination of the changes in chemical and elemental compositions on the surfaces of IOLs caused by the contact with silicone oil, IOLs were washed and rinsed with n-pentane to remove as much of the adsorbed silicone oil as possible, then subjected to Fourier transform infrared spectroscopic (FTIR) and X-ray photoelectron spectroscopic (XPS) analyses. The results of FTIR studies strongly indicate that washing with n-pentane completely removed the adhered silicone oil on the surfaces of PHEMA and Acrysof IOLs, whereas the residual silicone oil was detected on the surfaces of PMMA and silicone IOLs. XPS studies showed that silicone oil coverage of PMMA lenses was 12%, even after washing with n-pentane. In the case of silicone IOLs, the relative O1s peak area of carboxyl group in the residual CS-PDMS oil was found to be {approx}2.7%. Considering that 2.8% carboxyl group-substituted silicone oil was used in the present study, CS-PDMS oil covered the entire surface of the silicone IOLs.

  17. Does correcting astigmatism with toric lenses improve driving performance?

    Science.gov (United States)

    Cox, Daniel J; Banton, Thomas; Record, Steven; Grabman, Jesse H; Hawkins, Ronald J

    2015-04-01

    Driving is a vision-based activity of daily living that impacts safety. Because visual disruption can compromise driving safety, contact lens wearers with astigmatism may pose a driving safety risk if they experience residual blur from spherical lenses that do not correct their astigmatism or if they experience blur from toric lenses that rotate excessively. Given that toric lens stabilization systems are continually improving, this preliminary study tested the hypothesis that astigmats wearing toric contact lenses, compared with spherical lenses, would exhibit better overall driving performance and driving-specific visual abilities. A within-subject, single-blind, crossover, randomized design was used to evaluate driving performance in 11 young adults with astigmatism (-0.75 to -1.75 diopters cylinder). Each participant drove a highly immersive, virtual reality driving simulator (210 degrees field of view) with (1) no correction, (2) spherical contact lens correction (ACUVUE MOIST), and (3) toric contact lens correction (ACUVUE MOIST for Astigmatism). Tactical driving skills such as steering, speed management, and braking, as well as operational driving abilities such as visual acuity, contrast sensitivity, and foot and arm reaction time, were quantified. There was a main effect for type of correction on driving performance (p = 0.05). Correction with toric lenses resulted in significantly safer tactical driving performance than no correction (p driving safety from no correction (p = 0.118). Operational tests differentiated corrected from uncorrected performance for both spherical (p = 0.008) and toric (p = 0.011) lenses, but they were not sensitive enough to differentiate toric from spherical lens conditions. Given previous research showing that deficits in these tactical skills are predictive of future real-world collisions, these preliminary data suggest that correcting low to moderate astigmatism with toric lenses may be important to driving safety. Their

  18. A toric varieties approach to geometrical structure of multi partite states

    International Nuclear Information System (INIS)

    Heydari, Hoshang

    2010-01-01

    We investigate the geometrical structures of multipartite states based on construction of toric varieties. In particular, we describe pure quantum systems in terms of affine toric varieties and projective embedding of these varieties in complex projective spaces. We show that a quantum system can be corresponds to a toric variety of a fan which is constructed by gluing together affine toric varieties of polytopes. Moreover, we show that the projective toric varieties are the spaces of separable multipartite quantum states. The construction is a generalization of the complex multi-projective Segre variety. Our construction suggests a systematic way of looking at the structures of multipartite quantum systems.

  19. The topology of toric origami manifolds

    OpenAIRE

    Holm, Tara; Pires, Ana Rita

    2012-01-01

    A folded symplectic form on a manifold is a closed 2-form with the mildest possible degeneracy along a hypersurface. A special class of folded symplectic manifolds are the origami symplectic manifolds, studied by Cannas da Silva, Guillemin and Pires, who classified toric origami manifolds by combinatorial origami templates. In this paper, we examine the topology of toric origami manifolds that have acyclic origami template and co-orientable folding hypersurface. We prove that the cohomology i...

  20. Global embeddings for branes at toric singularities

    CERN Document Server

    Balasubramanian, Vijay; Braun, Volker; García-Etxebarria, Iñaki

    2012-01-01

    We describe how local toric singularities, including the Toric Lego construction, can be embedded in compact Calabi-Yau manifolds. We study in detail the addition of D-branes, including non-compact flavor branes as typically used in semi-realistic model building. The global geometry provides constraints on allowable local models. As an illustration of our discussion we focus on D3 and D7-branes on (the partially resolved) (dP0)^3 singularity, its embedding in a specific Calabi-Yau manifold as a hypersurface in a toric variety, the related type IIB orientifold compactification, as well as the corresponding F-theory uplift. Our techniques generalize naturally to complete intersections, and to a large class of F-theory backgrounds with singularities.

  1. Visual Outcomes after Phacoemulsification with AcrySof Toric ...

    African Journals Online (AJOL)

    2016-12-13

    Dec 13, 2016 ... The mean axis of rotation was 2.76 ± 1.88° in all eyes. Ninety percent of ... Myopia and hyperopia can be corrected by .... antibiotic eye drops for 4–6 weeks. ..... Cavallini GM, Campi L, Masini C, Pelloni S, Pupino A. Bimanual.

  2. Toric Varieties and Codes, Error-correcting Codes, Quantum Codes, Secret Sharing and Decoding

    DEFF Research Database (Denmark)

    Hansen, Johan Peder

    We present toric varieties and associated toric codes and their decoding. Toric codes are applied to construct Linear Secret Sharing Schemes (LSSS) with strong multiplication by the Massey construction. Asymmetric Quantum Codes are obtained from toric codes by the A.R. Calderbank P.W. Shor and A.......M. Steane construction of stabilizer codes (CSS) from linear codes containing their dual codes....

  3. Evaluation of Optical Quality: Ocular Scattering and Aberrations in Eyes Implanted with Diffractive Multifocal or Monofocal Intraocular Lenses.

    Science.gov (United States)

    Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun

    2018-06-01

    To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

  4. Toric Methods in F-Theory Model Building

    Directory of Open Access Journals (Sweden)

    Johanna Knapp

    2011-01-01

    Full Text Available We discuss recent constructions of global F-theory GUT models and explain how to make use of toric geometry to do calculations within this framework. After introducing the basic properties of global F-theory GUTs, we give a self-contained review of toric geometry and introduce all the tools that are necessary to construct and analyze global F-theory models. We will explain how to systematically obtain a large class of compact Calabi-Yau fourfolds which can support F-theory GUTs by using the software package PALP.

  5. Fluctuation in visual acuity during soft toric contact lens wear.

    Science.gov (United States)

    Chamberlain, Paul; Morgan, Philip B; Moody, Kurt J; Maldonado-Codina, Carole

    2011-04-01

    To quantify changes in visual acuity (VA) with soft toric contact lenses as a result of lens movement and/or rotational instability caused by versional eye movements. A novel chart for vision assessment at near (40 cm) for soft toric contact lenses (VANT chart),consisting of a central, color-coded logMAR panel and eight peripheral letter targets set on a white background measuring 60 × 40 cm was constructed. In the developmental phase of the work, 10 subjects (20 eyes) wore 2 toric lenses in random order, and the impact of rapid and delayed eye versions in 8 directions of gaze on VANT acuity was investigated. In phase 2, 35 subjects (68 eyes) wore 4 toric lenses in random order, and a streamlined clinical protocol using the VANT chart was implemented. Standard assessments of toric lens fit and distance VA were also performed. Testing in the first phase showed no difference for change in VA for rapid vs. delayed version movements, (p = 0.17) but acuity reduction was greater for diagonal compared with horizontal/vertical versions (p = 0.06). As such, testing in phase 2 proceeded using rapid, diagonal versions only. In this second phase, there were differences for low-contrast distance VA measures between lens types (p = 0.02) and for both VANT baseline acuity (p = 0.03) and postversion acuity (p = 0.04), but no differences were found between lenses for magnitude of vision loss (p = 0.91), which was about one line. No relationship was established between the magnitude of vision loss and measured rotational stability (p = 0.75). This work has demonstrated that conventional approaches to measuring VA do not fully replicate the "real world" experience of soft toric lens wearers. The VANT chart has shown that VA is reduced immediately after versional eye movements and suggests that more dynamic methods of assessing visual performance should be considered for soft toric contact lens wearers, especially given the apparent inability of lens stability measurements to predict

  6. Squashed Toric Sigma Models and Mock Modular Forms

    Science.gov (United States)

    Gupta, Rajesh Kumar; Murthy, Sameer

    2018-05-01

    We study a class of two-dimensional N}=(2,2)} sigma models called squashed toric sigma models, using their Gauged Linear Sigma Models (GLSM) description. These models are obtained by gauging the global {U(1)} symmetries of toric GLSMs and introducing a set of corresponding compensator superfields. The geometry of the resulting vacuum manifold is a deformation of the corresponding toric manifold in which the torus fibration maintains a constant size in the interior of the manifold, thus producing a neck-like region. We compute the elliptic genus of these models, using localization, in the case when the unsquashed vacuum manifolds obey the Calabi-Yau condition. The elliptic genera have a non-holomorphic dependence on the modular parameter {τ} coming from the continuum produced by the neck. In the simplest case corresponding to squashed {C / Z_{2 the elliptic genus is a mixed mock Jacobi form which coincides with the elliptic genus of the {N=(2,2)} {SL(2,R) / U(1)} cigar coset.

  7. Generating the Fukaya categories of compact toric varieties

    OpenAIRE

    Smith, Jack

    2018-01-01

    Let $X$ be a compact toric variety. The quantum cohomology of $X$ decomposes as a direct sum, and associated to each summand $Q$ is a toric fibre $L_Q$ with rank $1$ local system. By building an explicit twisted-complex-like object, we show that on $Q$ the Kodaira-Spencer isomorphism of Fukaya-Oh-Ohta-Ono factors through the closed-open string map to the Hochschild cohomology of $L_Q$. We deduce that the latter is injective and hence, assuming an appropriate version of Abouzaid's criterion, t...

  8. F-Theory on all Toric Hypersurface Fibrations and its Higgs Branches

    CERN Document Server

    Klevers, Denis; Oehlmann, Paul-Konstantin; Piragua, Hernan; Reuter, Jonas

    2015-01-01

    We consider F-theory compactifications on genus-one fibered Calabi-Yau manifolds with their fibers realized as hypersurfaces in the toric varieties associated to the 16 reflexive 2D polyhedra. We present a base-independent analysis of the codimension one, two and three singularities of these fibrations. We use these geometric results to determine the gauge groups, matter representations, 6D matter multiplicities and 4D Yukawa couplings of the corresponding effective theories. All these theories have a non-trivial gauge group and matter content. We explore the network of Higgsings relating these theories. Such Higgsings geometrically correspond to extremal transitions induced by blow-ups in the 2D toric varieties. We recover the 6D effective theories of all 16 toric hypersurface fibrations by repeatedly Higgsing the theories that exhibit Mordell-Weil torsion. We find that the three Calabi-Yau manifolds without section, whose fibers are given by the toric hypersurfaces in P^2, P^1x P^1 and the recently studied ...

  9. Refractive Lens Exchange with Multifocal Intraocular Lens for Treatment of Chronic Intermittent Spasm of the Near Reflex

    Directory of Open Access Journals (Sweden)

    Guy Sallet

    2017-12-01

    Full Text Available We report the case of an emmetropic 32-year-old female with decreased uncorrected visual acuity and diplopia due to intermittent episodes of spasm of the near reflex. Neurologic, general, and ophthalmic examination could not find an organic cause. Attempts at spontaneous recovery, psychogenic therapy, and cycloplegic therapy were unsuccessful and the symptoms persisted for almost 5 years, leading to psychogenic distress. Final treatment with refractive lens exchange and implantation of a toric trifocal intraocular lens resolved the spasm of the near reflex, resulting in an uncorrected distance and near visual acuity of 20/20.

  10. Do blue-light filtering intraocular lenses affect visual function?

    Science.gov (United States)

    Lavric, Alenka; Pompe, Manca Tekavcic

    2014-11-01

    To study different aspects of visual function, macular changes, and subjective differences between the eye with an ultraviolet (UV) and blue-light filtering intraocular lens (IOL) and the fellow eye with a UV-light filtering IOL. Thirty patients (60 eyes) with senile cataract had both cataracts extracted, and an IOL was implanted at least 2 years before clinical evaluation. In one eye, AcrySof SA60AT (a UV-light filtering IOL) was implanted, whereas in the contralateral eye, AcrySof IQ SN60WF (a blue-light filtering IOL) was implanted. Each patient underwent visual acuity testing, color vision testing (Ishihara and Farnsworth-Munsell 100-hue tests), and contrast sensitivity (CS) testing. The macula was evaluated with optical coherence tomography and with clinical examination. Patients were asked if they noted any difference between the implanted IOLs concerning visual impression. Subjective visual quality was evaluated using the National Eye Institute Visual Functioning Questionnaire. There was a borderline statistically significant difference in the mean best-corrected visual acuity (p = 0.05). As regards color vision, no significant changes in Ishihara and Farnsworth-Munsell 100-hue error scores were detected between both eyes (p = 0.48 and p = 0.59, respectively). Analysis of CS showed no significant difference between the groups at any spatial frequency. There were also no statistically significant differences in central macular thickness and total macular volume between the two IOL groups (p = 0.72 and p = 0.61, respectively). In both IOL groups, three eyes developed an epiretinal membrane, and six eyes developed early signs of age-related macular degeneration. This study showed no significant effects of a blue-light filtering IOL on visual acuity and no influence on color perception and CS. After more than 2 years, there were no significant differences in macular changes between the IOL groups. Clinical evidence of the effect of a blue-light filtering IOL on

  11. Gauge theories from toric geometry and brane tilings

    International Nuclear Information System (INIS)

    Franco, Sebastian; Hanany, Amihay; Martelli, Dario; Sparks, James; Vegh, David; Wecht, Brian

    2006-01-01

    We provide a general set of rules for extracting the data defining a quiver gauge theory from a given toric Calabi-Yau singularity. Our method combines information from the geometry and topology of Sasaki-Einstein manifolds, AdS/CFT, dimers, and brane tilings. We explain how the field content, quantum numbers, and superpotential of a superconformal gauge theory on D3-branes probing a toric Calabi-Yau singularity can be deduced. The infinite family of toric singularities with known horizon Sasaki-Einstein manifolds L a,b,c is used to illustrate these ideas. We construct the corresponding quiver gauge theories, which may be fully specified by giving a tiling of the plane by hexagons with certain gluing rules. As checks of this construction, we perform a-maximisation as well as Z-minimisation to compute the exact R-charges of an arbitrary such quiver. We also examine a number of examples in detail, including the infinite subfamily L a,b,a , whose smallest member is the Suspended Pinch Point

  12. Secant cumulants and toric geometry

    NARCIS (Netherlands)

    Michalek, M.; Oeding, L.; Zwiernik, P.W.

    2012-01-01

    We study the secant line variety of the Segre product of projective spaces using special cumulant coordinates adapted for secant varieties. We show that the secant variety is covered by open normal toric varieties. We prove that in cumulant coordinates its ideal is generated by binomial quadrics. We

  13. Prospective study of toric IOL outcomes based on the Lenstar LS 900® dual zone automated keratometer

    Directory of Open Access Journals (Sweden)

    Gundersen Kjell

    2012-07-01

    Full Text Available Abstract Background To establish clinical expectations when using the Lenstar LS 900® dual-zone automated keratometer for surgery planning of toric intraocular lenses. Methods Fifty eyes were measured with the Lenstar LS 900® dual-zone automated keratometer . Surgical planning was performed with the data from this device and the known surgically induced astigmatism of the surgeon. Post-operative refractions and visual acuity were measured at 1 month and 3 months. Results Clinical outcomes from 43 uncomplicated surgeries showed an average post-operative refractive astigmatism of 0.44D ±0.25D. Over 70% of eyes had 0.50D or less of refractive astigmatism and no eye had more than 1.0D of refractive astigmatism. Uncorrected visual acuity was 20/32 or better in all eyes at 3 months, with 70% of eyes 20/20 or better. A significantly higher number of eyes had 0.75D or more of post-operative refractive astigmatism when the standard deviation of the pre-operative calculated corneal astigmatism angle, reported by the keratometer, was > 5 degrees. Conclusions In this single-site study investigating the use of the keratometry from the Lenstar LS 900® for toric IOL surgical planning, clinical outcomes appear equivalent to those reported in the literature for manual keratometry and somewhat better than has been reported for some previous automated instruments. A high standard deviation in the pre-operative calculated astigmatism angle, as reported by the keratometer, appears to increase the likelihood of higher post-operative refractive astigmatism.

  14. Effects of blue light-filtering intraocular lenses on the macula, contrast sensitivity, and color vision after a long-term follow-up.

    Science.gov (United States)

    Kara-Junior, Newton; Espindola, Rodrigo F; Gomes, Beatriz A F; Ventura, Bruna; Smadja, David; Santhiago, Marcony R

    2011-12-01

    To evaluate the possible side effects and potential protection 5 years after implantation of an intraocular lens (IOL) with a blue-light filter (yellow tinted). Ophthalmology Department, University of São Paulo, São Paulo, Brazil. Prospective randomized clinical study. Patients with bilateral visually significant cataract randomly received an ultraviolet (UV) and blue light-filtering IOL (Acrysof Natural SN60AT) in 1 eye and an acrylic UV light-filtering only IOL (Acrysof SA60AT) in the fellow eye. The primary outcome measures were contrast sensitivity, color vision, and macular findings 5 years after surgery. The study enrolled 60 eyes of 30 patients. There were no significant clinical or optical coherence tomography findings in terms of age-related macular degeneration in any eye. There were no statistically significant differences in central macular thickness between the 2 IOL groups (P=.712). There were also no significant between-group differences under photopic or scotopic conditions at any spatial frequency studied. No statistically significant differences in the color discrimination test were found between the 2 IOL groups (P=.674). After 5 years, there were no significant differences in color perception, scotopic contrast sensitivity, or photopic contrast sensitivity between the blue light-filtering (yellow-tinted) IOL and the IOL with a UV-light filter only (untinted). The potential advantage of the tinted IOL in providing protection to macular cells remains unclear. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Q-factorial Gorenstein toric Fano varieties with large Picard number

    DEFF Research Database (Denmark)

    Nill, Benjamin; Øbro, Mikkel

    2010-01-01

    In dimension $d$, ${\\boldsymbol Q}$-factorial Gorenstein toric Fano varieties with Picard number $\\rho_X$ correspond to simplicial reflexive polytopes with $\\rho_X + d$ vertices. Casagrande showed that any $d$-dimensional simplicial reflexive polytope has at most $3 d$ and $3d-1$ vertices if $d......$ is even and odd, respectively. Moreover, for $d$ even there is up to unimodular equivalence only one such polytope with $3 d$ vertices, corresponding to the product of $d/2$ copies of a del Pezzo surface of degree six. In this paper we completely classify all $d$-dimensional simplicial reflexive polytopes...... having $3d-1$ vertices, corresponding to $d$-dimensional ${\\boldsymbol Q}$-factorial Gorenstein toric Fano varieties with Picard number $2d-1$. For $d$ even, there exist three such varieties, with two being singular, while for $d > 1$ odd there exist precisely two, both being nonsingular toric fiber...

  16. VISUAL ACUITY AND CLINICAL REFRACTION FOLLOWING IMPLANTATION OF VARIOUS MULTIFOCAL INTRAOCULAR LENSES

    Directory of Open Access Journals (Sweden)

    N. N. Temirov

    2015-01-01

    Full Text Available Aim. To analyze visual acuity, clinical refraction, and defocusing tolerance after the implantation of monofocal IOL with rotational asymmetric optic (Lentis Mplus 313 MF compared with Acrysof ReSTOR SN6AD1.Materials and methods. Phacoemulsification was performed in a total of 194 patients (288 eyes, i.e., 144 patients (188 eyes with cataract and 50 patients (100 eyes with presbyopia and high ametropia. The patients were divided into two groups. Study group included 132 patients (194 eyes implanted with Lentis Mplus while control group included 62 patients (94 eyes implanted with Acrysof ReSTOR. Uncorrected distance (5 m, intermediate (50‑70 cm, and near (20‑40 cm visual acuity under photopic (85 cd/m2 and mesopic (8 cd/m2 conditions were measured, objective and subjective refractometry were performed, and defocusing tolerance was evaluated.Results. Postoperatively, uncorrected distance and near visual acuity was high while intermediate visual acuity was moderately low. Lentis Mplus patients had better near and intermediate visual acuity under mesopic conditions as compared with Acrysof ReSTOR patients. Emmetropia (target refraction was achieved in 90.2% of study group patients and in 87.2% of control group patients. In patients implanted with Lentis Mplus, refraction was measured by subjective method. Optimal A-constant for Lentis Mplus and Acrysof ReSTOR was 118.0 and 118.6, respectively. Under defocusing, Lentis Mplus patients had better visual acuity than Acrysof ReSTOR patients. This indirectly confirms better intermediate vision.Conclusions. Lentis Mplus provides better vision at various distances that does not almost depend on light levels and induces minimal dysphotopsia. 

  17. Effects of a blue light-filtering intraocular lens on driving safety in glare conditions.

    Science.gov (United States)

    Gray, Rob; Hill, Warren; Neuman, Brooke; Houtman, Diane; Potvin, Richard

    2012-05-01

    To evaluate whether the previously established benefit of blue light-filtering intraocular lenses (IOLs) when driving in glare conditions is maintained in patients previously implanted with a blue light-filtering toric IOL. Department of Applied Psychology, Arizona State University, Mesa, Arizona, USA. Comparative case series. The study comprised patients with a blue light-filtering toric IOL (test IOL) or an ultraviolet (UV)-only filtering nontoric IOL (control IOL). All patients had good visual acuity and a valid driver's license. While wearing best spherocylindrical correction, patients performed left-turn maneuvers in front of oncoming traffic in a driving simulator. The safety margin was defined as the time to collision less the time taken to turn at an intersection with oncoming traffic. Measures were repeated with a glare source simulating low-angle sun conditions (daytime driving). Of the 33 evaluable patients, 18 had a test IOL and 15 had a control IOL. In the presence of glare, patients with test IOLs had significantly greater safety margins (mean 2.676 seconds ± 0.438 [SD]) than patients with control IOLs (mean 2.179 ± 0.343 seconds) and significantly lower glare susceptibility (P<.05). In no-glare and glare conditions, patients with test IOLs had significantly lower glare susceptibility than patients with control IOLs. The blue light-filtering toric IOL produced a significantly greater reduction in glare disability than the UV-only filtering nontoric IOL and increased the ability of drivers to safely execute left turns in low-sun conditions. Dr. Houtman is an employee of Alcon Laboratories, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Recurrence relations for toric N = 1 superconformal blocks

    Science.gov (United States)

    Hadasz, Leszek; Jaskólski, Zbigniew; Suchanek, Paulina

    2012-09-01

    General 1-point toric blocks in all sectors of N = 1 superconformal field theories are analyzed. The recurrence relations for blocks coefficients are derived by calculating their residues and large Δ asymptotics.

  19. Light-distortion analysis as a possible indicator of visual quality after refractive lens exchange with diffractive multifocal intraocular lenses.

    Science.gov (United States)

    Brito, Pedro; Salgado-Borges, José; Neves, Helena; Gonzalez-Meijome, José; Monteiro, Manuel

    2015-03-01

    To study the perception of light distortion after refractive lens exchange (RLE) with diffractive multifocal intraocular lenses (IOLs). Clínica Oftalmológica das Antas, Porto, Portugal. Retrospective comparative study. Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P light-distortion index and CDVA. The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses.

    Science.gov (United States)

    Marcos, Susana; Rosales, Patricia; Llorente, Lourdes; Jiménez-Alfaro, Ignacio

    2007-02-01

    To study the effect of cataract surgery through 3.2 mm superior incisions on corneal aberrations with 2 types of monofocal intraocular lenses (IOLs) with an aspherical design. Instituto de Optica, Consejo Superior de Investigaciones Científicas, and Fundación Jiménez Díaz, Madrid, Spain. Corneal topography of 43 eyes was obtained before and after small corneal incision cataract surgery. Twenty-two eyes had implantation of a Tecnis Z9000 silicone IOL (Advanced Medical Optics) and 21 had implantation of an AcrySof IQ SN60WF acrylic IOL (Alcon Research Labs) using the recommended injector for each IOL type. The intended incision size (3.2 mm) was similar in the 2 groups. Corneal aberrations were estimated using custom-developed algorithms (based on ray tracing) for 10.0 mm and 5.0 mm pupils. Comparisons between preoperative and postoperative measurements and across the groups were made for individual Zernike terms and root-mean-square (RMS) wavefront error. The RMS (excluding tilt and defocus) did not change in the AcrySof IQ group and increased significantly in the Tecnis group with the 10.0 mm and 5.0 mm pupil diameters. Spherical aberration and coma-like terms did not change significantly; however, vertical astigmatism, vertical trefoil, and vertical tetrafoil changed significantly with surgery with the 10.0 mm and 5.0 mm pupil diameters (Porder aberrations consistently showed a superior lobe, resulting from a combination of positive vertical trefoil (Z(3)(-3)) and negative tetrafoil (Z(4)(4)). The mean vertical astigmatism increased by 2.47 microm +/- 1.49 (SD) and 1.74 +/- 1.44 microm, vertical trefoil increased by 1.81 +/- 1.19 microm and 1.20 +/- 1.34 microm, and tetrafoil increased by -1.10 +/- 0.78 microm and -0.89 +/- 0.68 microm in the Tecnis group and AcrySof IQ group, respectively. There were no significant differences between the corneal aberrations in the 2 postoperative groups, although there was a tendency toward more terms or orders changing

  1. Anterior stromal puncture with staining: A modified technique for preoperative reference corneal marking for toric lenses and its retrospective analyses

    Directory of Open Access Journals (Sweden)

    Sahil Bhandari

    2016-01-01

    Full Text Available Introduction: Toric intraocular lenses (IOLs are an effective way of compensating preexisting corneal astigmatism during cataract surgery. To achieve success, it is imperative to align the toric IOLs in desired position and preoperative reference marking is one among the three important steps for accurate alignment. To make the marking procedure simpler and effective, we have modified the conventional three-step slit lamp-based technique. Materials and Methods: Patient is seated in front of the slit lamp and asked to keep the chin over chin rest. A 26-gauge bent needle with tip stained by sterile blue ink marker is used to make anterior stromal puncture (ASP at the edges of horizontal 180° axis near the limbus. Results: A total of 58 eyes were retrospectively evaluated. Mean (+/-SD IOL deviation on day 1 and day 30 was 5.7 ± 6.5° and 4.7 ± 5.6°, respectively. Median IOL misalignment on day 1 and day 30 was 3°. Redialing of IOL was required in 2 (3.4% eyes only, all of which were performed within 1 week of surgery. In total, 2 (3.7% eyes had a residual astigmatism of − 0.5 Dcyl and − 1.0 Dcyl, respectively. Conclusion: ASP is an effective technique for reference marking, technically simpler and can be practiced by most of the surgeons. It avoids the necessity of high-end sophisticated machinery and gives a better platform for the reference corneal marking along with the benefit of reproducibility and simplicity.

  2. Toric Geometry, Sasaki-Einstein Manifolds and a New Infinite Class of AdS/CFT Duals

    CERN Document Server

    Martelli, D; Martelli, Dario; Sparks, James

    2006-01-01

    Recently an infinite family of explicit Sasaki-Einstein metrics Y^{p,q} on S^2 x S^3 has been discovered, where p and q are two coprime positive integers, with qtoric. Aided by several recent results in toric geometry, we show that these are Kahler quotients C^4//U(1), namely the vacua of gauged linear sigma models with charges (p,p,-p+q,-p-q), thereby generalising the conifold, which is p=1,q=0. We present the corresponding toric diagrams and show that these may be embedded in the toric diagram for the orbifold C^3/Z_{p+1}xZ_{p+1} for all q

    toric quiver gauge theories with gauge group SU(N)^{2p}. As a non-trivial example, we show that Y^{2,1} is an explicit irregular Sasaki-Einstein metric on the horizon of the complex cone over the first del Pezz...

  3. F-theory on all toric hypersurface fibrations and its Higgs branches

    Energy Technology Data Exchange (ETDEWEB)

    Klevers, Denis [Department of Physics and Astronomy, University of Pennsylvania,Philadelphia, PA 19104-6396 (United States); Theory Group, Physics Department, CERN,CH-1211, Geneva 23 (Switzerland); Peña, Damián Kaloni Mayorga; Oehlmann, Paul-Konstantin [Bethe Center for Theoretical Physics, Physikalisches Institut der Universität Bonn,Nussallee 12, 53115 Bonn (Germany); Piragua, Hernan [Department of Physics and Astronomy, University of Pennsylvania,Philadelphia, PA 19104-6396 (United States); Reuter, Jonas [Bethe Center for Theoretical Physics, Physikalisches Institut der Universität Bonn,Nussallee 12, 53115 Bonn (Germany)

    2015-01-27

    We consider F-theory compactifications on genus-one fibered Calabi-Yau manifolds with their fibers realized as hypersurfaces in the toric varieties associated to the 16 reflexive 2D polyhedra. We present a base-independent analysis of the codimension one, two and three singularities of these fibrations. We use these geometric results to determine the gauge groups, matter representations, 6D matter multiplicities and 4D Yukawa couplings of the corresponding effective theories. All these theories have a non-trivial gauge group and matter content. We explore the network of Higgsings relating these theories. Such Higgsings geometrically correspond to extremal transitions induced by blow-ups in the 2D toric varieties. We recover the 6D effective theories of all 16 toric hypersurface fibrations by repeatedly Higgsing the theories that exhibit Mordell-Weil torsion. We find that the three Calabi-Yau manifolds without section, whose fibers are given by the toric hypersurfaces in ℙ{sup 2}, ℙ{sup 1}×ℙ{sup 1} and the recently studied ℙ{sup 2}(1,1,2), yield F-theory realizations of SUGRA theories with discrete gauge groups ℤ{sub 3}, ℤ{sub 2} and ℤ{sub 4}. This opens up a whole new arena for model building with discrete global symmetries in F-theory. In these three manifolds, we also find codimension two I{sub 2}-fibers supporting matter charged only under these discrete gauge groups. Their 6D matter multiplicities are computed employing ideal techniques and the associated Jacobian fibrations. We also show that the Jacobian of the biquadric fibration has one rational section, yielding one U(1)-gauge field in F-theory. Furthermore, the elliptically fibered Calabi-Yau manifold based on dP{sub 1} has a U(1)-gauge field induced by a non-toric rational section. In this model, we find the first F-theory realization of matter with U(1)-charge q=3.

  4. The sagitta and lens thickness: the exact solution and a matrix approximation for lenses with toric, spherical, and cylindrical surfaces.

    Science.gov (United States)

    Harris, W F

    1989-03-01

    The exact equation for sagitta of spherical surfaces is generalized to toric surfaces which include spherical and cylindrical surfaces as special cases. Lens thickness, therefore, can be calculated accurately anywhere on a lens even in cases of extreme spherical and cylindrical powers and large diameters. The sagittae of tire- and barrel-form toric surfaces differ off the principal meridians, as is shown by a numerical example. The same holds for pulley- and capstan-form toric surfaces. A general expression is given for thickness at an arbitrary point on a toric lens. Approximate expressions are derived and re-expressed in terms of matrices. The matrix provides an elegant means of generalizing equations for spherical surfaces and lenses to toric surfaces and lenses.

  5. Alpins and thibos vectorial astigmatism analyses: proposal of a linear regression model between methods

    Directory of Open Access Journals (Sweden)

    Giuliano de Oliveira Freitas

    2013-10-01

    Full Text Available PURPOSE: To determine linear regression models between Alpins descriptive indices and Thibos astigmatic power vectors (APV, assessing the validity and strength of such correlations. METHODS: This case series prospectively assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism between 0.75 and 2.50 diopters in both eyes. Patients were randomly assorted among two phacoemulsification groups: one assigned to receive AcrySof®Toric intraocular lens (IOL in both eyes and another assigned to have AcrySof Natural IOL associated with limbal relaxing incisions, also in both eyes. All patients were reevaluated postoperatively at 6 months, when refractive astigmatism analysis was performed using both Alpins and Thibos methods. The ratio between Thibos postoperative APV and preoperative APV (APVratio and its linear regression to Alpins percentage of success of astigmatic surgery, percentage of astigmatism corrected and percentage of astigmatism reduction at the intended axis were assessed. RESULTS: Significant negative correlation between the ratio of post- and preoperative Thibos APVratio and Alpins percentage of success (%Success was found (Spearman's ρ=-0.93; linear regression is given by the following equation: %Success = (-APVratio + 1.00x100. CONCLUSION: The linear regression we found between APVratio and %Success permits a validated mathematical inference concerning the overall success of astigmatic surgery.

  6. Secret Sharing Schemes with a large number of players from Toric Varieties

    DEFF Research Database (Denmark)

    Hansen, Johan P.

    A general theory for constructing linear secret sharing schemes over a finite field $\\Fq$ from toric varieties is introduced. The number of players can be as large as $(q-1)^r-1$ for $r\\geq 1$. We present general methods for obtaining the reconstruction and privacy thresholds as well as conditions...... for multiplication on the associated secret sharing schemes. In particular we apply the method on certain toric surfaces. The main results are ideal linear secret sharing schemes where the number of players can be as large as $(q-1)^2-1$. We determine bounds for the reconstruction and privacy thresholds...

  7. The toric SO(10) F-theory landscape

    International Nuclear Information System (INIS)

    Buchmuller, W.; Dierigl, M.; Oehlmann, P.K.; Ruehle, F.

    2017-09-01

    Supergravity theories in more than four dimensions with grand unified gauge symmetries are an important intermediate step towards the ultraviolet completion of the Standard Model in string theory. Using toric geometry, we classify and analyze six-dimensional F-theory vacua with gauge group SO(10) taking into account Mordell-Weil U(1) and discrete gauge factors. We determine the full matter spectrum of these models, including charged and neutral SO(10) singlets. Based solely on the geometry, we compute all matter multiplicities and confirm the cancellation of gauge and gravitational anomalies independent of the base space. Particular emphasis is put on symmetry enhancements at the loci of matter fields and to the frequent appearance of superconformal points. They are linked to non-toric Kaehler deformations which contribute to the counting of degrees of freedom. We compute the anomaly coefficients for these theories as well by using a base-independent blow-up procedure and superconformal matter transitions. Finally, we identify six-dimensional supergravity models which can yield the Standard Model with high-scale supersymmetry by further compactification to four dimensions in an Abelian flux background.

  8. The toric SO(10) F-theory landscape

    Energy Technology Data Exchange (ETDEWEB)

    Buchmuller, W.; Dierigl, M.; Oehlmann, P.K. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Ruehle, F. [Oxford Univ. (United Kingdom). Rudolf Peierls Centre for Theoretical Physics

    2017-09-15

    Supergravity theories in more than four dimensions with grand unified gauge symmetries are an important intermediate step towards the ultraviolet completion of the Standard Model in string theory. Using toric geometry, we classify and analyze six-dimensional F-theory vacua with gauge group SO(10) taking into account Mordell-Weil U(1) and discrete gauge factors. We determine the full matter spectrum of these models, including charged and neutral SO(10) singlets. Based solely on the geometry, we compute all matter multiplicities and confirm the cancellation of gauge and gravitational anomalies independent of the base space. Particular emphasis is put on symmetry enhancements at the loci of matter fields and to the frequent appearance of superconformal points. They are linked to non-toric Kaehler deformations which contribute to the counting of degrees of freedom. We compute the anomaly coefficients for these theories as well by using a base-independent blow-up procedure and superconformal matter transitions. Finally, we identify six-dimensional supergravity models which can yield the Standard Model with high-scale supersymmetry by further compactification to four dimensions in an Abelian flux background.

  9. Spontaneous Rotation of a Toric Implantable Collamer Lens

    Directory of Open Access Journals (Sweden)

    Alejandro Navas

    2010-11-01

    Full Text Available We present a case of toric implantable collamer lens (TICL spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA was 20/800 and 20/1200, respectively, with –7.75 –4.25 × 0° and –8.25 –5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 –4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months’ follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation.

  10. Three-form periods on Calabi-Yau fourfolds: toric hypersurfaces and F-theory applications

    Energy Technology Data Exchange (ETDEWEB)

    Greiner, Sebastian; Grimm, Thomas W. [Institute for Theoretical Physics and Center for Extreme Matter and Emergent Phenomena, Utrecht University,Leuvenlaan 4, 3584 CE Utrecht (Netherlands); Max-Planck-Institut für Physik, Föhringer Ring 6, 80805 Munich (Germany)

    2017-05-30

    The study of the geometry of Calabi-Yau fourfolds is relevant for compactifications of string theory, M-theory, and F-theory to various dimensions. This work introduces the mathematical machinery to derive the complete moduli dependence of the periods of non-trivial three-forms for fourfolds realized as hypersurfaces in toric ambient spaces. It sets the stage to determine Picard-Fuchs-type differential equations and integral expressions for these forms. The key tool is the observation that non-trivial three-forms on fourfold hypersurfaces in toric ambient spaces always stem from divisors that are build out of trees of toric surfaces fibered over Riemann surfaces. The three-form periods are then non-trivially related to the one-form periods of these Riemann surfaces. In general, the three-form periods are known to vary holomorphically over the complex structure moduli space and play an important role in the effective actions arising in fourfold compactifications. We discuss two explicit example fourfolds for F-theory compactifications in which the three-form periods determine axion decay constants.

  11. The quantum equivariant cohomology of toric manifolds through mirror symmetry

    NARCIS (Netherlands)

    Baptista, J.M.

    2009-01-01

    Using mirror symmetry as described by Hori and Vafa, we compute the quantum equivariant cohomology ring of toric manifolds. This ring arises naturally in topological gauged sigma-models and is related to the Hamiltonian Gromov-Witten invariants of the target manifold.

  12. The quantum equivariant cohomology of toric manifolds through mirror symmetry

    OpenAIRE

    Baptista, J. M.

    2008-01-01

    Using mirror symmetry as described by Hori and Vafa, we compute the quantum equivariant cohomology ring of toric manifolds. This ring arises naturally in topological gauged sigma-models and is related to the Hamiltonian Gromov-Witten invariants of the target manifold.

  13. Line bundle twisted chiral de Rham complex and bound states of D-branes on toric manifolds

    International Nuclear Information System (INIS)

    Parkhomenko, S.E.

    2014-01-01

    In this note we calculate elliptic genus in various examples of twisted chiral de Rham complex on two-dimensional toric compact manifolds and Calabi–Yau hypersurfaces in toric manifolds. At first the elliptic genus is calculated for the line bundle twisted chiral de Rham complex on a compact smooth toric manifold and K3 hypersurface in P 3 . Then we twist chiral de Rham complex by sheaves localized on positive codimension submanifolds in P 2 and calculate in each case the elliptic genus. In the last example the elliptic genus of chiral de Rham complex on P 2 twisted by SL(N) vector bundle with instanton number k is calculated. In all the cases considered we find the infinite tower of open string oscillator contributions and identify directly the open string boundary conditions of the corresponding bound state of D-branes

  14. Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery.

    Science.gov (United States)

    Savini, Giacomo; Hoffer, Kenneth J; Barboni, Piero

    2015-04-01

    To evaluate the possible influence of anterior corneal surface asphericity on the refractive outcomes in eyes having intraocular lens (IOL) implantation after cataract surgery. Fondazione G.B. Bietti IRCCS, Rome, Italy. Retrospective comparative case series. Intraocular lens power was calculated using the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Asphericity (Q-value) was measured at 8.0 mm with a Placido-disk corneal topographer (Keratron), a rotating Scheimpflug camera (Pentacam), and a rotating Scheimpflug camera combined with Placido-disk corneal topography (Sirius). The relationship between the error in refraction prediction (ie, difference between expected refraction and refraction measured 1 month after surgery) and the Q-value was assessed by linear regression. The same IOL model (Acrysof SA60AT) was implanted in 115 eyes of 115 consecutive patients. Regression analysis showed a statistically significant relationship between the error in refraction prediction and the Q-value with all formulas and all devices. In all cases, a more negative Q-value (prolate cornea) was associated with a myopic outcome, whereas a more positive Q-value (oblate cornea) was associated with a hyperopic outcome. The highest coefficient of determination was detected between the Hoffer Q formula and the Placido-disk corneal topographer (R(2) = 0.2630), for which the error in refraction prediction (y) was related to the Q-value (x) according to the formula y = -0.2641 + 1.4589 × x. Corneal asphericity influences the refractive outcomes of IOL implantation and should be taken into consideration when using third-generation IOL power formulas. Dr. Hoffer receives book royalties from Slack, Inc., Thorofare, New Jersey, and formula royalties from all manufacturers using the Hoffer Q formula. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. D-branes at toric singularities: model building, Yukawa couplings and flavour physics

    International Nuclear Information System (INIS)

    Krippendorf, Sven; Dolan, Matthew J.; Maharana, Anshuman; Quevedo, Fernando

    2010-02-01

    We discuss general properties of D-brane model building at toric singularities. Using dimer techniques to obtain the gauge theory from the structure of the singularity, we extract results on the matter sector and superpotential of the corresponding gauge theory. We show that the number of families in toric phases is always less than or equal to three, with a unique exception being the zeroth Hirzebruch surface. With the physical input of three generations we find that the lightest family of quarks is massless and the masses of the other two can be hierarchically separated. We compute the CKM matrix for explicit models in this setting and find the singularities possess sufficient structure to allow for realistic mixing between generations and CP violation. (author)

  16. Use of the Toric Surgical Marker to Aid in Intraoperative Plaque Placement for the USC Eye Physics Plaques to Treat Uveal Melanoma: A New Surgical Technique.

    Science.gov (United States)

    Berry, Jesse L; Kim, Jonathan W; Jennelle, Richard; Astrahan, Melvin

    2015-09-01

    To describe a new surgical technique for intraoperative placement of Eye Physics (EP) plaques for uveal melanoma using a toric marker. A toric marker is designed for cataract surgery to align the axis of astigmatism; its use was modified in this protocol to mark the axis of suture coordinates as calculated by Plaque Simulator (PS) software. The toric marker can be used to localize suture coordinates, in degrees, during intraoperative plaque placement. Linear marking using the toric marker decreases potential inaccuracies associated with the surgeon estimating 'clock-hours' by dot placement. Use of the toric marker aided surgical placement of EP plaques. The EP planning protocol is now designed to display the suture coordinates either by clock-hours or degrees, per surgeon preference. Future research is necessary to determine whether routine use of the toric marker improves operative efficiency. [Ophthalmic Surg Lasers Imaging Retina. 2015;46:866-870.]. Copyright 2015, SLACK Incorporated.

  17. Analysis of quantum error-correcting codes: Symplectic lattice codes and toric codes

    Science.gov (United States)

    Harrington, James William

    Quantum information theory is concerned with identifying how quantum mechanical resources (such as entangled quantum states) can be utilized for a number of information processing tasks, including data storage, computation, communication, and cryptography. Efficient quantum algorithms and protocols have been developed for performing some tasks (e.g. , factoring large numbers, securely communicating over a public channel, and simulating quantum mechanical systems) that appear to be very difficult with just classical resources. In addition to identifying the separation between classical and quantum computational power, much of the theoretical focus in this field over the last decade has been concerned with finding novel ways of encoding quantum information that are robust against errors, which is an important step toward building practical quantum information processing devices. In this thesis I present some results on the quantum error-correcting properties of oscillator codes (also described as symplectic lattice codes) and toric codes. Any harmonic oscillator system (such as a mode of light) can be encoded with quantum information via symplectic lattice codes that are robust against shifts in the system's continuous quantum variables. I show the existence of lattice codes whose achievable rates match the one-shot coherent information over the Gaussian quantum channel. Also, I construct a family of symplectic self-dual lattices and search for optimal encodings of quantum information distributed between several oscillators. Toric codes provide encodings of quantum information into two-dimensional spin lattices that are robust against local clusters of errors and which require only local quantum operations for error correction. Numerical simulations of this system under various error models provide a calculation of the accuracy threshold for quantum memory using toric codes, which can be related to phase transitions in certain condensed matter models. I also present

  18. 6D F-theory models and elliptically fibered Calabi-Yau threefolds over semi-toric base surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Martini, Gabriella; Taylor, Washington [Center for Theoretical Physics, Department of Physics, Massachusetts Institute of Technology,77 Massachusetts Avenue, Cambridge, MA 02139 (United States)

    2015-06-10

    We carry out a systematic study of a class of 6D F-theory models and associated Calabi-Yau threefolds that are constructed using base surfaces with a generalization of toric structure. In particular, we determine all smooth surfaces with a structure invariant under a single ℂ{sup ∗} action (sometimes called “T-varieties” in the mathematical literature) that can act as bases for an elliptic fibration with section of a Calabi-Yau threefold. We identify 162,404 distinct bases, which include as a subset the previously studied set of strictly toric bases. Calabi-Yau threefolds constructed in this fashion include examples with previously unknown Hodge numbers. There are also bases over which the generic elliptic fibration has a Mordell-Weil group of sections with nonzero rank, corresponding to non-Higgsable U(1) factors in the 6D supergravity model; this type of structure does not arise for generic elliptic fibrations in the purely toric context.

  19. 6D F-theory models and elliptically fibered Calabi-Yau threefolds over semi-toric base surfaces

    International Nuclear Information System (INIS)

    Martini, Gabriella; Taylor, Washington

    2015-01-01

    We carry out a systematic study of a class of 6D F-theory models and associated Calabi-Yau threefolds that are constructed using base surfaces with a generalization of toric structure. In particular, we determine all smooth surfaces with a structure invariant under a single ℂ ∗ action (sometimes called “T-varieties” in the mathematical literature) that can act as bases for an elliptic fibration with section of a Calabi-Yau threefold. We identify 162,404 distinct bases, which include as a subset the previously studied set of strictly toric bases. Calabi-Yau threefolds constructed in this fashion include examples with previously unknown Hodge numbers. There are also bases over which the generic elliptic fibration has a Mordell-Weil group of sections with nonzero rank, corresponding to non-Higgsable U(1) factors in the 6D supergravity model; this type of structure does not arise for generic elliptic fibrations in the purely toric context.

  20. Dynamic balancing of planar mechanisms using toric geometry

    OpenAIRE

    Moore, Brian; Schicho, Josef; Gosselin, Clement M.

    2007-01-01

    In this paper, a new method to determine the complete set of dynamically balanced planar four-bar mechanims is presented. Using complex variables to model the kinematics of the mechanism, the dynamic balancing constraints are written as algebraic equations over complex variables and joint angular velocities. After elimination of the joint angular velocity variables, the problem is formulated as a problem of factorization of Laurent polynomials. Using toric polynomial division, necessary and s...

  1. Intraocular pressure reduction and regulation system

    Science.gov (United States)

    Baehr, E. F.; Burnett, J. E.; Felder, S. F.; Mcgannon, W. J.

    1979-01-01

    An intraocular pressure reduction and regulation system is described and data are presented covering performance in: (1) reducing intraocular pressure to a preselected value, (2) maintaining a set minimum intraocular pressure, and (3) reducing the dynamic increases in intraocular pressure resulting from external loads applied to the eye.

  2. An angle-supported foldable phakic intraocular lens for correction of myopia: A five-year follow-up.

    Science.gov (United States)

    Alió, J L; Plaza-Puche, A B; Cavas, F; Yébana Rubio, P; Sala, E

    2017-01-01

    To evaluate the efficacy and safety of an angle-supported foldable phakic intraocular lens (pIOL) for the correction of moderate to high myopia after 5 years follow-up. Prospective and retrospective, observational, longitudinal, non-randomised consecutive series of cases conducted on a total of 100 eyes of 67 patients with moderate to high myopia implanted with an Acrysof Cachet pIOL (Alcon Laboratories Inc.) with the aim of minimising the refractive error. The ages ranged between 18 to 60years. Uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity (CDVA), endothelial cells density, pIOL position, intraocular pressure, and complications were recorded preoperatively and during the 5 year follow-up. Five years after implantation, the mean manifest spherical equivalent refraction reduced significantly from -11.62±3.35 dioptres (D) to -0.33±0.85D. UDVA was 20/20 or better in 5 of 25 cases (20%), and 20/40 or better in 22 cases (88%). CDVA was 20/20 or better in 17 cases (68%), and 20/32 or better in 23 cases (92%) of eyes. The residual refractive error was within ±0.50D of emmetropia in 12 cases (48%), and within ±1.00D in 19 cases (76%). Mean endothelial cell loss at 5 years was 11.8% central, and 13.7% peripheral. Mean endothelium-pIOL distance was 2.11±0.18mm, and mean pIOL-crystalline distance was 0.88±0.20mm. This angle supported pIOL provided a favourable refractive correction and predictability, as well as acceptable safety in patients with moderate to high myopia. Although endothelial cell density decreased over 5years, the results are within the range reported in previous studies with other pIOLs. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Toric Lego: A method for modular model building

    CERN Document Server

    Balasubramanian, Vijay; García-Etxebarria, Iñaki

    2010-01-01

    Within the context of local type IIB models arising from branes at toric Calabi-Yau singularities, we present a systematic way of joining any number of desired sectors into a consistent theory. The different sectors interact via massive messengers with masses controlled by tunable parameters. We apply this method to a toy model of the minimal supersymmetric standard model (MSSM) interacting via gauge mediation with a metastable supersymmetry breaking sector and an interacting dark matter sector. We discuss how a mirror procedure can be applied in the type IIA case, allowing us to join certain intersecting brane configurations through massive mediators.

  4. Topological open string amplitudes on local toric del Pezzo surfaces via remodeling the B-model

    International Nuclear Information System (INIS)

    Manabe, Masahide

    2009-01-01

    We study topological strings on local toric del Pezzo surfaces by a method called remodeling the B-model which was recently proposed by Bouchard, Klemm, Marino and Pasquetti. For a large class of local toric del Pezzo surfaces we prove a functional formula of the Bergman kernel which is the basic constituent of the topological string amplitudes by the topological recursion relation of Eynard and Orantin. Because this formula is written as a functional of the period, we can obtain the topological string amplitudes at any point of the moduli space by a simple change of variables of the Picard-Fuchs equations for the period. By this formula and mirror symmetry we compute the A-model amplitudes on K F 2 , and predict the open orbifold Gromov-Witten invariants of C 3 /Z 4 .

  5. An analysis of the visual results when using toric lenses in cataract surgery

    Directory of Open Access Journals (Sweden)

    Astor Grumann Junior

    2015-02-01

    Full Text Available Purpose: To evaluate the postoperative results when using the toric IOL during phacoemulsification. Methods: Retrospective cohort based study on the 95 eyes of 67 patients, selected by a census. Analyzed patients with cataracts who had undergone phacoemulsification placement with AcrySof® toric IOL from january 2010 to december 2012. For analysis purposes, it was considered successful when the residual astigmatism was d”0.75 diopters. The Wilcoxon test for related samples was used to compare non-parametric samples, while the Student T test was used for samples with normal distribution. A p d”0.05 significance level was granted. Results: The average age of the population was 73.00 (±10.87, there was a higher incidence of females (56.8% and no difference in the side of the affected eye. The average preoperative spherical component was 0.86 (±2.89, since the average cylindrical component was -1.53 (±1.09, with a predominance of the shaft against the rule (51.6%. The logarithmic visual acuity (logMAR preoperative average was 0.32 (±0.25. The average postoperative spherical component was -0.02 (±0.53. Surgical success was obtained in 71 eyes (74.7% having a significant decrease (p <0.001 in the cylindrical component and postoperative logarithmic visual acuity, with the respective values of - 0.61 (±0.55 and 0.08 (±0.14, with the remaining axis against the rule (33.7%. Conclusions: The toric lenses were safe and reproducible with regards to postoperative results and therefore an important option for obtaining excellent final refractometric results.

  6. Clinical Evaluation of Reading Performance Using the Salzburg Reading Desk With a Refractive Rotational Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Linz, Katharina; Attia, Mary S A; Khoramnia, Ramin; Tandogan, Tamer; Kretz, Florian T; Auffarth, Gerd Uwe

    2016-08-01

    To evaluate functional results and reading performance using the Salzburg Reading Desk after implantation of a sector-shaped near-embedded, rotational asymmetrical multifocal intraocular lens (IOL) and a multifocal toric IOL with a +3.00 diopter (D) near addition. In a prospective study, the LentisMplus and Mplus toric IOLs (Oculentis GmbH, Berlin, Germany) were implanted in 34 eyes of 18 patients at the University Eye Hospital of Heidelberg. Uncorrected and corrected distance visual acuity (UDVA, CDVA) and uncorrected and corrected near visual acuity (UNVA, CNVA) were evaluated using standardized visual acuity charts (ETDRS). The Salzburg Reading Desk was used to analyze unilateral and bilateral uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at a set (40 cm/80 cm) and subjective chosen near and intermediate distance. Postoperatively, the median UDVA was 0.08 logMAR (20/25 Snellen) and the median CDVA was 0.01 logMAR (20/20 Snellen). The median UNVA was 0.12 logMAR (20/25 Snellen) and the median CNVA was 0.03 logMAR (20/20 Snellen). The median uncorrected reading acuity measured with the Salzburg Reading Desk for near distance at 40 cm was 0.18 logMAR (20/32 Snellen). The subjectively preferred near distance was 39 cm and revealed similar visual acuity results. The best reading acuity for intermediate distance with a median of 0.22 logMAR (20/32 Snellen) was achieved at a median distance of 62 cm. Reading performance of the multifocal IOL corresponded for near standardized and individual distance, whereas reading function was better at the patient's preferred intermediate distance. [J Refract Surg. 2016;32(8):526-532.]. Copyright 2016, SLACK Incorporated.

  7. Intraocular (Eye) Melanoma—Health Professional Version

    Science.gov (United States)

    Intraocular (uveal) melanoma of the uveal tract (iris, ciliary body, and choroid), though rare, is the most common primary intraocular malignancy in adults. Find evidence-based information on intraocular melanoma treatment.

  8. Toric codes and quantum doubles from two-body Hamiltonians

    Energy Technology Data Exchange (ETDEWEB)

    Brell, Courtney G; Bartlett, Stephen D; Doherty, Andrew C [Centre for Engineered Quantum Systems, School of Physics, University of Sydney, Sydney (Australia); Flammia, Steven T, E-mail: cbrell@physics.usyd.edu.au [Perimeter Institute for Theoretical Physics, Waterloo (Canada)

    2011-05-15

    We present here a procedure to obtain the Hamiltonians of the toric code and Kitaev quantum double models as the low-energy limits of entirely two-body Hamiltonians. Our construction makes use of a new type of perturbation gadget based on error-detecting subsystem codes. The procedure is motivated by a projected entangled pair states (PEPS) description of the target models, and reproduces the target models' behavior using only couplings that are natural in terms of the original Hamiltonians. This allows our construction to capture the symmetries of the target models.

  9. [Correlation of intraocular pressure variation after visual field examination with 24-hour intraocular pressure variations in primary open-angle glaucoma].

    Science.gov (United States)

    Noro, Takahiko; Nakamoto, Kenji; Sato, Makoto; Yasuda, Noriko; Ito, Yoshinori; Ogawa, Shumpei; Nakano, Tadashi; Tsuneoka, Hiroshi

    2014-10-01

    We retrospectively examined intraocular pressure variations after visual field examination in primary open angle glaucoma (POAG), together with its influencing factors and its association with 24-hour intraocular pressure variations. Subjects were 94 eyes (52 POAG patients) subjected to measurements of 24-hour intraocular pressure and of changes in intraocular pressure after visual field examination using a Humphrey Visual Field Analyzer. Subjects were classified into three groups according to the magnitude of variation (large, intermediate and small), and 24-hour intraocular pressure variations were compared among the three groups. Factors influencing intraocular pressure variations after visual field examination and those associated with the large variation group were investigated. Average intraocular pressure variation after visual field examination was -0.28 ± 1.90 (range - 6.0(-) + 5.0) mmHg. No significant influencing factors were identified. The intraocular pressure at 3 a.m. was significantly higher in the large variation group than other two groups (p field examination. Increases in intraocular pressure during the night might be associated with large intraocular pressure variations after visual field examination.

  10. Refined toric branes, surface operators and factorization of generalized Macdonald polynomials

    Science.gov (United States)

    Zenkevich, Yegor

    2017-09-01

    We find new universal factorization identities for generalized Macdonald polynomials on the topological locus. We prove the identities (which include all previously known forumlas of this kind) using factorization identities for matrix model averages, which are themselves consequences of Ding-Iohara-Miki constraints. Factorized expressions for generalized Macdonald polynomials are identified with refined topological string amplitudes containing a toric brane on an intermediate preferred leg, surface operators in gauge theory and certain degenerate CFT vertex operators.

  11. INTRAOCULAR CORRECTION OF PRESBYOPIA BY MONOVISION IN PATIENTS WITH CATARACT AND CORNEAL ASTIGMATISM

    Directory of Open Access Journals (Sweden)

    E. I. Belikova

    2017-01-01

    Full Text Available Purpose: To evaluate the results of intraocular correction of presbyopia by monovision in patients with cataract and primary corneal astigmatism and conduct a comparative analysis of these outcomes with the results of binocular multifocal IOLs implantation. Patients and methods. There were 21 patients with bilateral cataract surgery performed using toric monofocal intraocular lenses (monovision group in the study. The indications for the operation were: 1 primary corneal astigmatism ≥ 1.0D in patients with cataract, 2 inability to conduct excimer laser correction. Reduction of spectacle dependence by monovision was discussed during preoperative conversation. The age of patients range from 32 to 65 years. Target refraction: Emetronopia on the dominant eye (DG and myopia at 1.0–2.0 D in the non-dominant eye (NDG. Evaluation included measurement of uncorrected visual acuity, refraction, stereopsis, contrast sensitivity and patient satisfaction. The results were compared with the outcomes of binocular multifocal Iols implantation in 22 patients (44 eyes. Results. The spherical component decreased from 3.39±2.63D to 0.34±0.24D, cylinder decreased from 3.05±1.47D to 0.44±0,35D (P <0.01 in the monovision group three months after surgery . The deviation from target refraction was 0.30±0.35D. The mean difference between postoperative refraction on the two eyes was 1.92±0.57D. Postoperative corrected visual acuity significantly exceeded preoperative parameters. In 18 patients (88% the stereoscopic visual acuity did not exceed 60 seconds and corresponded to the age norm, in 3 patients (12% it was at the level of 80–100 arc seconds. In patients with multifocal IOLs, the stereovision values were identical (Ferrer-Blasco T. et al, 2008. Conclusion. The monovision is an effective method of reducing dependence on additional correction in patients with cataract and corneal astigmatism. Refractive outcomes, binocular visual acuity, predictability and

  12. Intraocular lymphoma

    Directory of Open Access Journals (Sweden)

    Li-Juan Tang

    2017-08-01

    Full Text Available Intraocular lymphoma (IOL is a rare lymphocytic malignancy which contains two main distinct forms. Primary intraocular lymphoma (PIOL is mainly a sub-type of primary central nervous system lymphoma (PCNSL. Alternatively, IOL can originate from outside the central nervous system (CNS by metastasizing to the eye. These tumors are known as secondary intraocular lymphoma (SIOL. The IOL can arise in the retina, uvea, vitreous, Bruch’s membrane and optic nerve. There are predominantly of B-cell origin; however there are also rare T-cell variants. Diagnosis remains challenging for ophthalmologists and pathologists, due to its ability to masquerade as noninfectious or infectious uveitis, white dot syndromes, or occasionally as other metastatic cancers. Laboratory tests include flow cytometry, immunocytochemistry, interleukin detection (IL-10: IL-6, ratio >1, and polymerase chain reaction (PCR amplification. Methotrexate-based systemic chemotherapy with external beam radiotherapy and intravitreal chemotherapy with methotrexate are useful for controlling the disease, but the prognosis remains poor. Therefore, it is important to make an early diagnose and treatment. This review is focused on the clinical manifestations, diagnosis, treatment and prognosis of the IOL.

  13. SECRET SHARING SCHEMES WITH STRONG MULTIPLICATION AND A LARGE NUMBER OF PLAYERS FROM TORIC VARIETIES

    DEFF Research Database (Denmark)

    Hansen, Johan Peder

    2017-01-01

    This article consider Massey's construction for constructing linear secret sharing schemes from toric varieties over a finite field $\\Fq$ with $q$ elements. The number of players can be as large as $(q-1)^r-1$ for $r\\geq 1$. The schemes have strong multiplication, such schemes can be utilized in ...

  14. Correlating optical bench performance with clinical defocus curves in varifocal and trifocal intraocular lenses.

    Science.gov (United States)

    Plaza-Puche, Ana B; Alió, Jorge L; MacRae, Scott; Zheleznyak, Len; Sala, Esperanza; Yoon, Geunyoung

    2015-05-01

    To investigate the correlations existing between a trifocal intraocular lens (IOL) and a varifocal IOL using the "ex vivo" optical bench through-focus image quality analysis and the clinical visual performance in real patients by study of the defocus curves. This prospective, consecutive, nonrandomized, comparative study included a total of 64 eyes of 42 patients. Three groups of eyes were differentiated according to the IOL implanted: 22 eyes implanted with the varifocal Lentis Mplus LS-313 IOL (Oculentis GmbH, Berlin, Germany); 22 eyes implanted with the trifocal FineVision IOL (Physiol, Liege, Belgium), and 20 eyes implanted with the monofocal Acrysof SA60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Visual outcomes and defocus curve were evaluated postoperatively. Optical bench through-focus performance was quantified by computing an image quality metric and the cross-correlation coefficient between an unaberrated reference image and captured retinal images from a model eye with a 3.0-mm artificial pupil. Statistically significant differences among defocus curves of different IOLs were detected for the levels of defocus from -4.00 to -1.00 diopters (D) (P < .01). Significant correlations were found between the optical bench image quality metric results and logMAR visual acuity scale in all groups (Lentis Mplus group: r = -0.97, P < .01; FineVision group: r = -0.82, P < .01; Acrys of group: r = -0.99, P < .01). Linear predicting models were obtained. Significant correlations were found between logMAR visual acuity and image quality metric for the multifocal and monofocal IOLs analyzed. This finding enables surgeons to predict visual outcomes from the optical bench analysis. Copyright 2015, SLACK Incorporated.

  15. Comparison of two optical biometers in intraocular lens power calculation

    Directory of Open Access Journals (Sweden)

    Sheng Hui

    2014-01-01

    Full Text Available Aims: To compare the consistency and accuracy in ocular biometric measurements and intraocular lens (IOL power calculations using the new optical low-coherence reflectometry and partial coherence interferometry. Subjects and Methods: The clinical data of 122 eyes of 72 cataract patients were analyzed retrospectively. All patients were measured with a new optical low-coherence reflectometry system, using the LENSTAR LS 900 (Haag Streit AG/ALLEGRO BioGraph biometer (Wavelight., AG, and partial coherence interferometry (IOLMaster V.5.4 [Carl Zeiss., Meditec, AG] before phacoemulsification and IOL implantation. Repeated measurements, as recommended by the manufacturers, were performed by the same examiner with both devices. Using the parameters of axial length (AL, corneal refractive power (K1 and K2, and anterior chamber depth (ACD, power calculations for AcrySof SA60AT IOL were compared between the two devices using five formulas. The target was emmetropia. Statistical analysis was performed using Statistical Package for the Social Sciences software (SPSS 13.0 with t-test as well as linear regression. A P value < 0.05 was considered to be statistically significant. Results: The mean age of 72 cataract patients was 64.6 years ± 13.4 [standard deviation]. Of the biometry parameters, K1, K2 and [K1 + K2]/2 values were significantly different between the two devices (mean difference, K1: −0.05 ± 0.21 D; K2: −0.12 ± 0.20 D; [K1 + K2]/2: −0.08 ± 0.14 D. P <0.05. There was no statistically significant difference in AL and ACD between the two devices. The correlations of AL, K1, K2, and ACD between the two devices were high. The mean differences in IOL power calculations using the five formulas were not statistically significant between the two devices. Conclusions: New optical low-coherence reflectometry provides measurements that correlate well to those of partial coherence interferometry, thus it is a precise device that can be used for the

  16. Retreatments after multifocal intraocular lens implantation: an analysis

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-03-01

    Full Text Available Kjell Gunnar Gundersen,1 Sarah Makari,2 Steffen Ostenstad,1 Rick Potvin2 1Ifocus Eye Clinic, Haugesund, Norway; 2Science in Vision, Akron, NY, USA Purpose: To determine the incidence and etiology of required retreatment after multifocal intraocular lens (IOL implantation and to evaluate the methods and clinical outcomes of retreatment.Patients and methods: A retrospective chart review of 416 eyes of 209 patients from one site that underwent uncomplicated cataract surgery with multifocal IOL implantation. Biometry, the IOL, and refractive data were recorded after the original implantation, with the same data recorded after retreatment. Comments related to vision were obtained both before and after retreatment for retreated patients.Results: The multifocal retreatment rate was 10.8% (45/416 eyes. The eyes that required retreatment had significantly higher residual refractive astigmatism compared with those who did not require retreatment (1.21±0.51 D vs 0.51±0.39 D, P<0.01. The retreatment rate for the two most commonly implanted primary IOLs, blended bifocal (10.5%, 16/152 and bilateral trifocal (6.9%, 14/202 IOLs, was not statistically significantly different (P=0.12. In those requiring retreatment, refractive-related complaints were most common. Retreatment with refractive corneal surgery, in 11% of the eyes, and piggyback IOLs, in 89% of the eyes, was similarly successful, improving patient complaints 78% of the time.Conclusion: Complaints related to ametropia were the main reasons for retreatment. Residual astigmatism appears to be an important determinant of retreatment rate after multifocal IOL implantation. Retreatment can improve symptoms for a high percentage of patients; a piggyback IOL is a viable retreatment option. Keywords: piggyback IOL, Sulcoflex, toric, STAAR, symptoms, astigmatism

  17. Correction of low corneal astigmatism in cataract surgery.

    Science.gov (United States)

    Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele

    2015-01-01

    To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.

  18. Flag varieties, toric varieties, and suspensions: Three instances of infinite transitivity

    International Nuclear Information System (INIS)

    Arzhantsev, Ivan V; Zaidenberg, M G; Kuyumzhiyan, Karine G

    2012-01-01

    We say that a group G acts infinitely transitively on a set X if for every m element of N the induced diagonal action of G is transitive on the cartesian mth power X m backslash Δ with the diagonals removed. We describe three classes of affine algebraic varieties such that their automorphism groups act infinitely transitively on their smooth loci. The first class consists of normal affine cones over flag varieties, the second of nondegenerate affine toric varieties, and the third of iterated suspensions over affine varieties with infinitely transitive automorphism groups. Bibliography: 42 titles.

  19. Entanglement negativity and sudden death in the toric code at finite temperature

    Science.gov (United States)

    Hart, O.; Castelnovo, C.

    2018-04-01

    We study the fate of quantum correlations at finite temperature in the two-dimensional toric code using the logarithmic entanglement negativity. We are able to obtain exact results that give us insight into how thermal excitations affect quantum entanglement. The toric code has two types of elementary excitations (defects) costing different energies. We show that an O (1 ) density of the lower energy defect is required to degrade the zero-temperature entanglement between two subsystems in contact with one another. However, one type of excitation alone is not sufficient to kill all quantum correlations, and an O (1 ) density of the higher energy defect is required to cause the so-called sudden death of the negativity. Interestingly, if the energy cost of one of the excitations is taken to infinity, quantum correlations survive up to arbitrarily high temperatures, a feature that is likely shared with other quantum spin liquids and frustrated systems in general, when projected down to their low-energy states. We demonstrate this behavior both for small subsystems, where we can prove that the negativity is a necessary and sufficient condition for separability, as well as for extended subsystems, where it is only a necessary condition. We further observe that the negativity per boundary degree of freedom at a given temperature increases (parametrically) with the size of the boundary, and that quantum correlations between subsystems with extended boundaries are more robust to thermal fluctuations.

  20. Visual Performance of a Quadrifocal (Trifocal) Intraocular Lens Following Removal of the Crystalline Lens.

    Science.gov (United States)

    Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam

    2017-12-01

    To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Cionni ring and in-the-bag intraocular lens implantation for subluxated lenses: a prospective case series.

    Science.gov (United States)

    Vasavada, Abhay R; Praveen, Mamidipudi R; Vasavada, Viraj A; Yeh, Ru-Yin; Srivastava, Samaresh; Koul, Archana; Trivedi, Rupal H

    2012-06-01

    To report the intraoperative performance and postoperative outcomes of the Cionni-modified capsule tension ring (CTR) implantation in eyes with subluxated lenses. Prospective, observational case series. This study was carried out at Iladevi Cataract & IOL Research Centre, Ahmedabad, India. The study population comprised 41 eyes with subluxated lenses that underwent lens extraction, capsular bag fixation with modified CTR, and in-the-bag single-piece AcrySof intraocular lens (IOL) implantation. Main outcome measures were intraoperative performance and postoperative best-corrected visual acuity (BCVA), IOL centration, and complications. The mean age was 29.46 ± 16.16 years (3-68 years). Mean extent of subluxation was 6.1 ± 1.0 clock hours. Preoperatively, vitreous was detected in the anterior chambers of 5 eyes (12.2%). Two-port anterior chamber vitrectomy was performed in 2 eyes. Mean follow-up was 45.8 ± 2.9 months. Mean preoperative BCVA was 0.66 ± 0.22 logMAR (35 eyes). Mean postoperative BCVA at final follow-up was 0.33 ± 0.21 logMAR (41 eyes) (P IOL decentration was noted and repositioning was required in 2 eyes. Posterior capsule opacification developed in 14 eyes (34.2%); 12 eyes (29.3%) required Nd:YAG capsulotomy. Other complications included cystoid macular edema in 1 eye (2.4%), posterior synechiae in 1 eye (2.4%), and retinal detachment in 1 eye (2.4%). In-the-bag implantation of a Cionni-modified CTR with IOL appears to be a safe option in eyes with subluxated cataract, ensuring a stable IOL with few complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Intraocular inflammation in autoimmune diseases.

    Science.gov (United States)

    Pras, Eran; Neumann, Ron; Zandman-Goddard, Gisele; Levy, Yair; Assia, Ehud I; Shoenfeld, Yehuda; Langevitz, Pnina

    2004-12-01

    The uveal tract represents the vascular organ of the eye. In addition to providing most of the blood supply to the intraocular structures, it acts as a conduit for immune cells, particularly lymphocytes, to enter the eye. Consequently, the uveal tract is represented in many intraocular inflammatory processes. Uveitis is probably a misnomer unless antigens within the uvea are the direct targets of the inflammatory process. A better term of the condition is "intraocular inflammation" (IOI). To review the presence of IOI in autoimmune diseases, the immunopathogenic mechanisms leading to disease, and treatment. We reviewed the English medical literature by using MEDLINE (1984-2003) employing the terms "uveitis," "intraocular inflammation," and "autoimmune diseases." An underlying autoimmune disease was identified in up to 40% of patients with IOI, and included spondyloarthropathies, Behcets disease, sarcoidosis, juvenile chronic arthritis, Vogt-Koyanagi-Harada syndrome (an inflammatory syndrome including uveitis with dermatologic and neurologic manifestations), immune recovery syndrome, and uveitis with tubulointerstitial disease. The immunopathogenesis of IOI involves enhanced T-cell response. Recently, guidelines for the use of immunosuppressive drugs for inflammatory eye disease were established and include: corticosteroids, azathioprine, methotrexate, mycophenolate mofetil, cyclosporine, tacrolimus, cyclophosphamide, and chlorambucil. New therapies with limited experience include the tumor necrosis factor alpha inhibitors, interferon alfa, monoclonal antibodies against lymphocyte surface antigens, intravenous immunoglobulin (IVIG), and the intraocular delivery of immunosuppressive agents. An underlying autoimmune disease was identified in up to 40% of patients with IOI. Immunosuppressive drugs, biologic agents, and IVIG are employed for the treatment of IOI in autoimmune diseases.

  3. Correction of low corneal astigmatism in cataract surgery

    Directory of Open Access Journals (Sweden)

    Pia Leon

    2015-08-01

    Full Text Available AIM: To evaluate and compare aspheric toric intraocular lens (IOL implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI to manage low corneal astigmatism (1.0-2.0 D in cataract surgery.METHODS:A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were:visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan. Follow-up lasted 6mo.RESULTS: The mean uncorrected distance visual acuity (UCVA and the best corrected visual acuity (BCVA demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01. No difference was observed in the postoperative endothelial cell count between the two groups.CONCLUSION: The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.

  4. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  5. 21 CFR 886.4275 - Intraocular fluid.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4275 Intraocular fluid. (a) Identification. An intraocular fluid is a device consisting of a nongaseous fluid intended to be introduced into the eye to aid... section 515 of the act is required before this device may be commercially distributed. See § 886.3. ...

  6. Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    The objective of this analysis is to review the effectiveness, safety, and cost-effectiveness of phakic intraocular lenses (pIOLs) for the treatment of myopia, hyperopia, and astigmatism. CONDITION AND TARGET POPULATION REFRACTIVE ERRORS: Refractive errors occur when the eye cannot focus light properly. In myopia (near- or short-sightedness), distant objects appear blurry because the axis of the eye is too long or the cornea is too steep, so light becomes focused in front of the retina. Hyperopia (far sightedness) occurs when light is focused behind the retina causing nearby objects to appear blurry. In astigmatism, blurred or distorted vision occurs when light is focused at two points rather than one due to an irregularly shaped cornea or lens. Refractive errors are common worldwide, but high refractive errors are less common. In the United States, the prevalence of high myopia (≤ -5 D) in people aged 20 to 39, 40 to 59, and 60 years and older is 7.4% (95% confidence interval [CI], 6.5% - 8.3%), 7.8% (95% CI, 6.4% - 8.6%), and 3.1% (95% CI, 2.2% - 3.9%), respectively. The prevalence of high hyperopia (≥ 3 D) is 1.0% (95% CI, .6% - 1.4%), 2.4% (95% CI, 1.7% - 3.0%), and 10.0% (95% CI, 9.1% - 10.9%) for the same age groupings. Finally, the prevalence of astigmatism (≥ 1 D cylinder) is 23.1% (95% CI, 21.6% - 24.5%), 27.6% (95% CI, 25.8% - 29.3%) and 50.1% (48.2% - 52.0%). LOW VISION: According to the Ontario Schedule of Benefits, low visual acuity is defined by a best spectacle corrected visual acuity (BSCVA) of 20/50 (6/15) or less in the better eye and not amenable to further medical and/or surgical treatment. Similarly, the Ontario Assistive Devices Program defines low vision as BSCVA in the better eye in the range of 20/70 or less that cannot be corrected medically, surgically, or with ordinary eyeglasses or contact lenses. Estimates of the prevalence of low vision vary. Using the criteria of BSCVA ranging from 20/70 to 20/160, one study estimated that 35

  7. A Case Report of Intraocular Metastasis Treated with Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Bae; Byun, Sang Jun; Kim, Kwang Soo; Kim, Jin Hee [Keimyung University School of Medicine, Daegu (Korea, Republic of); Lee, Ho Jun [Daegu Catholic University School of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    Intraocular metastasis is the most common malignancy of the eye. The frequency of intraocular metastasis in all the patients dying of cancer is about 12% and ocular metastases will be detected more frequently in the future because the patients with malignant tumor are now living longer. Intraocular metastasis can cause a serious clinical problem such as blindness. The early recognition and treatment of intraocular metastasis are very important clinical oncologic issues to maintain vision and to maximize the quality of life. However, significance of intraocular metastasis is still under-evaluated for practicing oncologists. External beam radiotherapy is a safe, effective palliative treatment in terms of preserving both the vision and the eye globe.

  8. 21 CFR 886.4270 - Intraocular gas.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4270 Intraocular gas. (a) Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place pressure... required. As of May 28, 1976, an approval under section 515 of the act is required before this device may...

  9. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

    Science.gov (United States)

    Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina

    2014-04-01

    To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.

  10. A common humoral background of intraocular and arterial blood pressure dysregulation.

    Science.gov (United States)

    Skrzypecki, Janusz; Grabska-Liberek, Iwona; Przybek, Joanna; Ufnal, Marcin

    2018-03-01

    It has been postulated that intraocular pressure, an important glaucoma risk factor, correlates positively with arterial blood pressure (blood pressure). However, results of experimental and clinical studies are often contradictory. It is hypothesized that, in some hypertensive patients, disturbances in intraocular pressure regulation may depend on biological effects of blood borne hormones underlying a particular type of hypertension, rather than on blood pressure level itself. This review compares the effects of hormones on blood pressure and intraocular pressure, in order to identify a hormonal profile of hypertensive patients with an increased risk of intraocular pressure surge. The PUBMED database was searched to identify pre-clinical and clinical studies investigating the role of angiotensin II, vasopressin, adrenaline, noradrenaline, prostaglandins, and gaseous transmitters in the regulation of blood pressure and intraocular pressure. Studies included in the review suggest that intraocular and blood pressures often follow a different pattern of response to the same hormone. For example, vasopressin increases blood pressure, but decreases intraocular pressure. In contrast, high level of nitric oxide decreases blood pressure, but increases intraocular pressure. Arterial hypertension is associated with altered levels of blood borne hormones. Contradicting results of studies on the relationship between arterial hypertension and intraocular pressure might be partially explained by diverse effects of hormones on arterial and intraocular pressures. Further studies are needed to evaluate if hormonal profiling may help to identify glaucoma-prone patients.

  11. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct... lenses, the device is exempt from the premarket notification procedures in subpart E of part 807 of this...

  12. [Refractive precision and objective quality of vision after toric lens implantation in cataract surgery].

    Science.gov (United States)

    Debois, A; Nochez, Y; Bezo, C; Bellicaud, D; Pisella, P-J

    2012-10-01

    To study efficacy and predictability of toric IOL implantation for correction of preoperative corneal astigmatism by analysing spherocylindrical refractive precision and objective quality of vision. Prospective study of 13 eyes undergoing micro-incisional cataract surgery through a 1.8mm corneal incision with toric IOL implantation (Lentis L313T(®), Oculentis) to treat over one D of preoperative corneal astigmatism. Preoperative evaluation included keratometry, subjective refraction, and total and corneal aberrometry (KR-1(®), Topcon). Six months postoperatively, measurements included slit lamp photography, documenting IOL rotation, tilt or decentration, uncorrected visual acuity, best-corrected visual acuity and objective quality of vision measurement (OQAS(®) Visiometrics, Spain). Postoperatively, mean uncorrected distance visual acuity was 8.33/10 ± 1.91 (0.09 ± 0.11 LogMar). Mean postoperative refractive sphere was 0.13 ± 0.73 diopters. Mean refractive astigmatism was -0.66 ± 0.56 diopters with corneal astigmatism of 2.17 ± 0.68 diopters. Mean IOL rotation was 4.4° ± 3.6° (range 0° to 10°). Mean rotation of this IOL at 6 months was less than 5°, demonstrating stability of the optic within the capsular bag. Objective quality of vision measurements were consistent with subjective uncorrected visual acuity. Implantation of the L313T(®) IOL is safe and effective for correction of corneal astigmatism in 1.8mm micro-incisional cataract surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  13. DESIGN OF THE MULTIORDER INTRAOCULAR LENSES

    Directory of Open Access Journals (Sweden)

    V. G. Kolobrodov

    2015-01-01

    Full Text Available Intraocular lenses (IOLs are used to replace the natural crystalline lens of the eye. Just few basic designs of IOLs are used clinically. Multiorder diffractive lenses (MODL which operate simultaneously in several diffractive orders were proposed to decrease the chromatic aberration. Properties analysis of MODL showed a possibility to use them to develop new designs of IOLs. The purpose of this paper was to develop a new method of designing of multiorder intraocular lenses with decreased chromatic aberration. The theoretical research of the lens properties was carried out. The diffraction efficiency dependence with the change of wavelength was studied. A computer simulation of MODL in a schematic model of the human eye was carried out. It is found the capability of the multiorder diffractive lenses to focus polychromatic light into a segment on the optical axis with high diffraction efficiency. At each point of the segment is present each component of the spectral range, which will build a color image in combination. The paper describes the new design method of intraocular lenses with reduced chromaticism and with endless adaptation. An optical system of an eye with an intraocular lens that provides sharp vision of objects located at a distance of 700 mm to infinity is modeled.

  14. Lente intra-ocular multifocal difrativa apodizada: resultados Diffractive apodized multifocal intraocular lens: results

    Directory of Open Access Journals (Sweden)

    Virgilio Centurion

    2007-12-01

    Full Text Available OBJETIVO: Mostrar os resultados visuais e refracionais com lente intra-ocular multifocal difrativa apodizada. MÉTODOS: Estudo de 100 olhos de 50 pacientes com catarata, submetidos à facoemulsificação com implante bilateral de lente intra-ocular (LIO multifocal difrativa apodizada. Foi avaliada a acuidade visual binocular sem e com correção para longe e perto, a previsibilidade refracional e a freqüência de uso de óculos. RESULTADOS: A acuidade visual sem correção para longe foi de e " 20/30 em 97,56% dos olhos operados e e" J2 em 100%, sendo que 82% dos pacientes nunca usam óculos e 16% usam de forma esporádica. CONCLUSÃO: A LIO multifocal difrativa apodizada mostrou ser uma opção previsível, reproduzível e segura na correção dos vícios de refração para longe e perto durante a cirurgia da catarata, permitindo elevado índice de independência ao uso de óculos.OBJECTIVE: To show visual and refraction results using multifocal diffractive apodized intraocular lens. METHODS: The study of 100 eyes of 50 patients with cataract, submitted to phacoemulsification with bilateral implant of multifocal diffractive apodized intraocular lens (IOL. Binocular visual acuity was evaluated with and without correction for near and distance, and refraction previsibility and frequency of wearing glasses. RESULTS: Visual acuity without correction for distance was e" 20/30 in 97.56% of eyes operated on and e" J2 in 100%, of these 82% of patients never wear glasses and 16% wear glasses sporadically. CONCLUSION: Multifocal diffractive apodized IOL proved to be a foreseeable option, reproducible and safe in the correction of refraction errors for distance and near during cataract surgery, enabling a high rate of independence from the use of glasses.

  15. Relation between intraocular pressure and size of transverse sinuses

    Energy Technology Data Exchange (ETDEWEB)

    Kantarci, Mecit; Onbas, Omer; Alper, Fatih; Okur, Adnan [Atatuerk University, Department of Radiology, Medical Faculty, Erzurum (Turkey); Dane, Senol; Gumustekin, Kenan [Atatuerk University, Department of Physiology, Medical Faculty, Erzurum (Turkey); Aslankurt, Murat [Atatuerk University, Department of Ophtalmatology, Medical Faculty, Erzurum (Turkey); Yazici, Ahmet Taylan [Beyoglu Goez Egitim ve Arastirma Hastanesi, Istanbul (Turkey)

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean{+-}SD; 19.72{+-}0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. (orig.)

  16. Relation between intraocular pressure and size of transverse sinuses

    International Nuclear Information System (INIS)

    Kantarci, Mecit; Onbas, Omer; Alper, Fatih; Okur, Adnan; Dane, Senol; Gumustekin, Kenan; Aslankurt, Murat; Yazici, Ahmet Taylan

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean±SD; 19.72±0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. (orig.)

  17. Logical error rate scaling of the toric code

    International Nuclear Information System (INIS)

    Watson, Fern H E; Barrett, Sean D

    2014-01-01

    To date, a great deal of attention has focused on characterizing the performance of quantum error correcting codes via their thresholds, the maximum correctable physical error rate for a given noise model and decoding strategy. Practical quantum computers will necessarily operate below these thresholds meaning that other performance indicators become important. In this work we consider the scaling of the logical error rate of the toric code and demonstrate how, in turn, this may be used to calculate a key performance indicator. We use a perfect matching decoding algorithm to find the scaling of the logical error rate and find two distinct operating regimes. The first regime admits a universal scaling analysis due to a mapping to a statistical physics model. The second regime characterizes the behaviour in the limit of small physical error rate and can be understood by counting the error configurations leading to the failure of the decoder. We present a conjecture for the ranges of validity of these two regimes and use them to quantify the overhead—the total number of physical qubits required to perform error correction. (paper)

  18. Acute Retention of Urine Following Intraocular Surgery | Nwosu ...

    African Journals Online (AJOL)

    Hyperosmolar agents and carbonic anhydrase inhibitors are used to lower the intraocular pressure and thus minimize the chances of vitreous loss during intraocular surgery. However, these agents could precipitate urinary retention. This is a report on two elderly men who had perioperative acute urinary retention following ...

  19. Intraocular osseous metaplasia. A clinico-pathological study

    OpenAIRE

    Vemuganti Geeta; Honavar Santosh; Jalali Subhadra

    2002-01-01

    Purpose: To evaluate the clinico-pathologic features of intraocular osseous metaplasia. Methods: Pathology specimens of enucleated eyes submitted to the ophthalmic pathology service at a tertiary eye-care referral center between January 1995 and June 1999 were studied for intraocular osseous metaplasia. Specific histopathologic features noted in specimens with osseous metaplasia were the presence of retinal detachment, gliosis, retinal pigment epithelial hyperplasia, drusen, epiretinal membra...

  20. Resultados da troca de lente intra-ocular de hidrogel opacificada

    Directory of Open Access Journals (Sweden)

    Salera Cristina Moreira

    2004-01-01

    Full Text Available OBJETIVO: Avaliar os resultados da explantação e substituição das lentes intra-oculares (LIO de hidrogel opacificadas. MÉTODOS: Foram analisados retrospectivamente os prontuários de 12 pacientes (15 olhos submetidos à explantação e substituição das lentes intra-oculares de hidrogel opacificadas. RESULTADOS: A opacificação das lentes intra-oculares de hidrogel causou perdas de linhas de visão em 13 olhos (86,7%. A troca das lentes intra-oculares opacificadas promoveu o ganho de linhas de visão em 11 olhos (73,3%. As complicações peroperatórias ocorreram em três olhos (20% e foram as seguintes: perda de óleo de silicone, ruptura total de zônula com perda do saco capsular e ruptura parcial de zônula. Durante a explantação das lentes intra-oculares foi necessária a realização de incisões relaxantes na borda da capsulorrexe anterior em três olhos (20% e em dois olhos (13,3% os hápticos foram cortados sendo retirada somente a zona óptica das lentes intra-oculares. CONCLUSÃO: A cirurgia para explantação e substituição das lentes intra-oculares opacificadas mostrou-se eficaz naqueles pacientes com perdas de linhas de visão (p > 0,05.

  1. Importance of intraocular pressure in glaucoma

    Science.gov (United States)

    Joos, Karen M.

    1999-06-01

    Glaucoma results in permanent vision loss and affects the peripheral vision initially. It is presented in 22.5 million people worldwide and is the 3rd cause of blindness. Present tonometers are not ideal for intraocular pressure measurements in all eyes. Of concern, PRK and LASIK may result in lower intraocular pressure readings. A challenges now exists for the development of a tonometer which can easily compensate for corneas with many parameters to avoid a future increase in normal-tension glaucoma or glaucoma which is advanced.

  2. Solid intraocular xanthogranuloma in three Miniature Schnauzer dogs.

    Science.gov (United States)

    Zarfoss, Mitzi K; Dubielzig, Richard R

    2007-01-01

    Macrophages that contain abundant intracytoplasmic lipid are called 'foam cells'. In four canine globes submitted to the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW), foam cells formed a solid intraocular mass. The purpose of this study was to describe the histopathologic findings in these cases. The electronic COPLOW database (1993-2006) was searched for the diagnosis of 'foam cell tumor'. Clinical history, gross pathology and histopathology (5-micron sections, hematoxylin and eosin and Alcian blue periodic acid Schiff) were reviewed in all cases. Cases were included if the globe was grossly filled by a solid mass and if all intraocular structures were effaced by lipid-laden foam cell macrophages admixed with birefringent, Alcian blue-positive crystals oriented in stellate patterns. All three patients (four globes) satisfying the selection criteria were Miniature Schnauzers. In all cases the clinical history included diabetes mellitus, hyperlipidemia and chronic bilateral uveitis that was interpreted to be lens-induced. All globes were enucleated because of glaucoma. The term solid intraocular xanthogranuloma was used to describe these cases because the intraocular contents were effaced by a solid mass of foam cells and birefringent crystals. The cases in this report suggest that diabetic Miniature Schnauzers with hyperlipidemia are at risk for lipid and macrophage-rich uveitis, which may in some cases form a solid inflammatory intraocular mass, precipitate glaucoma, and lead to enucleation.

  3. The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure

    Directory of Open Access Journals (Sweden)

    Ilhan Ece

    2015-01-01

    Full Text Available Objective. This study aims to explore the usage of intraocular pressure measurements as the early indicator of the increase in intra-abdominal pressure. Methods. In this prospective study, 40 patients undergoing elective surgery were included. Patients were divided into four groups of 10 patients. The control group (Group C was not subjected to laparoscopic intervention. Laparoscopic surgery was, respectively, performed with an intra-abdominal pressure of 9, 12, and 15 mmHg in Groups L (low, M (medium, and H (high pressure. Intraocular pressure was measured binocularly in each patient at three different times (before, during, and end of surgery using a contact tonometer. Results. Patients’ gender, age, body mass index (BMI, American Society of Anesthesiology (ASA class, and operative times were not different among the groups. No complications occurred with either the surgery or measurement of intraocular pressure. Intubation was associated with a severe rise in IOP (P<0.05. An increase in intraocular pressure was seen in groups M and H (P<0.05. Conclusion. Intraocular pressure was increased in the groups with an intra-abdominal pressure of 12 mmHg or more. Measuring the intraocular pressure might be a useful method to estimate the intra-abdominal pressure. This trial is registered with NCT02319213.

  4. Resultados de implante de lente intraocular en niños Results of intraocular lens implantation in children

    Directory of Open Access Journals (Sweden)

    Nashelly I. Mejía Cruz

    2007-12-01

    Full Text Available En este estudio se describen los resultados obtenidos del implante de lente intraocular en niños, quienes acudieron al servicio de Oftalmología Pediátrica de Instituto Cubano de oftalmología “Ramón Pando Ferrer” con el diagnóstico de catarata de diversas etiologías, en período comprendido entre abril del 2002 al 2005 cuyo seguimiento fue durante un año. En nuestro universo de estudio se determinan algunos parámetros como la edad del paciente, etiología de las cataratas, agudeza visual, defecto refractivo preoperatorio y posoperatorio. Se identificó el poder dióptrico del lente intraocular más frecuente, la presencia de complicaciones durante la cirugía y después de esta. Se evaluaron finalmente, los pacientes que requerían de tratamiento adicional como la capsulotomía con láser o membranectomía quirúrgica. El implante del lente intraocular a temprana edad se relacionó con buenos resultados quirúrgicos: mejoría de la agudeza visual corregida, presentándose el astigmatismo como el error refractivo más frecuente. La complicación transoperatorio y postoperatoria más frecuente fue la membrana inflamatoria, mientras que la complicación posoperatoria más frecuente fue la opacidad de la cápsula posterior.This paper described the results of the intraocular lens implantation performed in children, who had been seen at the Pediatric Ophthalmologic Service of " Ramon Pando Ferrer " Cuban Institute of Ophthalmology and had been diagnosed as having cataract of various etiologies, from April 2002 to April 2005. They were all followed-up for a year. Some parameters like the patient’s age, the etiology of cataract, visual acuity, pre-operative and post-operative refractive defect were considered in our study. The dioptric power of the most common intraocular lens and the most frequent complications during and after surgery were identified. The patients requiring additional treatment such as laser capsulotomy and surgical

  5. Outcomes of iris-claw anterior chamber versus iris-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome.

    Science.gov (United States)

    Hirashima, Denise E; Soriano, Eduardo S; Meirelles, Rodrigo L; Alberti, Gustave N; Nosé, Walton

    2010-08-01

    To compare the outcome of phacoemulsification using 2 different iris-fixation techniques for intraocular lens (IOL) replacement, a foldable posterior chamber IOL (PCIOL; AcrySof MA60AC, Alcon Laboratories Inc, Fort Worth, TX) and an iris-claw anterior chamber IOL (ACIOL; Artisan, Ophtec BV), for treatment of subluxated lenses in patients with Marfan syndrome (MFS). Randomized, controlled trial. A total of 31 eyes of 16 patients with subluxated lenses associated with MFS and a preoperative corrected visual acuity (CVA) IOL type. Preoperative and postoperative ophthalmologic examination, optical coherence tomography, and endothelial cell counts were performed. We recorded CVA results at 3, 6, and 12 months, complications, endothelial cell loss, and central retinal thickness. In the iris-fixated PCIOL group, CVA was significantly improved at 3 (P = 0.011; n = 16), 6 (P = 0.006; n = 16), and 12 months (P = 0.002; n = 16). In the iris-claw ACIOL group, CVA was significantly improved at 3 (P = 0.001; n=15), 6 (P = 0.001; n = 15), and 12 months (P = 0.009; n = 12). The CVA results did not differ significantly between groups. Dislocation of the IOL occurred in 3 of 16 (18.75%) eyes in the PCIOL group. Retinal detachment occurred in 3 eyes (2 in the PCIOL group and 1 in the ACIOL group) and was successfully repaired. Postoperative foveal tomograms in both groups revealed a decrease in the mean foveal thickness (MFT; IOL dislocation tended to occur more frequently in the iris-fixated PCIOL group, the difference was not significant. At 6 months postoperatively, all study patients tended to have a thinner MFT. None of the patients in either group developed cystoid macular edema. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Self-dual random-plaquette gauge model and the quantum toric code

    Science.gov (United States)

    Takeda, Koujin; Nishimori, Hidetoshi

    2004-05-01

    We study the four-dimensional Z2 random-plaquette lattice gauge theory as a model of topological quantum memory, the toric code in particular. In this model, the procedure of quantum error correction works properly in the ordered (Higgs) phase, and phase boundary between the ordered (Higgs) and disordered (confinement) phases gives the accuracy threshold of error correction. Using self-duality of the model in conjunction with the replica method, we show that this model has exactly the same mathematical structure as that of the two-dimensional random-bond Ising model, which has been studied very extensively. This observation enables us to derive a conjecture on the exact location of the multicritical point (accuracy threshold) of the model, pc=0.889972…, and leads to several nontrivial results including bounds on the accuracy threshold in three dimensions.

  7. Self-dual random-plaquette gauge model and the quantum toric code

    International Nuclear Information System (INIS)

    Takeda, Koujin; Nishimori, Hidetoshi

    2004-01-01

    We study the four-dimensional Z 2 random-plaquette lattice gauge theory as a model of topological quantum memory, the toric code in particular. In this model, the procedure of quantum error correction works properly in the ordered (Higgs) phase, and phase boundary between the ordered (Higgs) and disordered (confinement) phases gives the accuracy threshold of error correction. Using self-duality of the model in conjunction with the replica method, we show that this model has exactly the same mathematical structure as that of the two-dimensional random-bond Ising model, which has been studied very extensively. This observation enables us to derive a conjecture on the exact location of the multicritical point (accuracy threshold) of the model, p c =0.889972..., and leads to several nontrivial results including bounds on the accuracy threshold in three dimensions

  8. The effect of intraocular gas and fluid volumes on intraocular pressure.

    Science.gov (United States)

    Simone, J N; Whitacre, M M

    1990-02-01

    Large increases in the intraocular pressure (IOP) of postoperative gas-containing eyes may require the removal of gas or fluid to reduce the IOP to the normal range. Application of the ideal gas law to Friedenwald's equation provides a mathematical model of the relationship between IOP, intraocular gas and fluid volumes, and the coefficient of scleral rigidity. This mathematic model shows that removal of a given volume of gas or fluid produces an identical decrease in IOP and that the more gas an eye contains, the greater the volume reduction necessary to reduce the pressure. Application of the model shows that the effective coefficient of scleral rigidity is low (mean K, 0.0021) in eyes with elevated IOP that have undergone vitrectomy and retinal cryopexy and very low (mean K, 0.0013) in eyes with elevated IOP that have undergone placement of a scleral buckle and band. By using the appropriate mean coefficient of rigidity, the volume of material to be aspirated to produce a given decrease in IOP can be predicted with clinically useful accuracy.

  9. Commercial air travel after intraocular gas injection.

    Science.gov (United States)

    Houston, Stephen; Graf, Jürgen; Sharkey, James

    2012-08-01

    Passengers with intraocular gas are at risk of profound visual loss when exposed to reduced absolute pressure within the cabin of a typical commercial airliner. Information provided on the websites of the world's 10 largest airlines offer a considerable range of opinion as to when it might be safe to fly after gas injection. Physicians responsible for clearing pseassengers as 'fit to fly' should be aware modern retinal surgical techniques increasingly employ long-acting gases as vitreous substitutes. The kinetics of long-acting intraocular gases must be considered when deciding how long after surgery it is safe to travel. It is standard practice to advise passengers not to fly in aircraft until the gas is fully resorbed. To achieve this, it may be necessary to delay travel for approximately 2 wk after intraocular injection of sulfur hexafluoride (SF6) and for 6 wk after injection of perfluoropropane (C3F8).

  10. Dynamic simulation of the effect of soft toric contact lenses movement on retinal image quality.

    Science.gov (United States)

    Niu, Yafei; Sarver, Edwin J; Stevenson, Scott B; Marsack, Jason D; Parker, Katrina E; Applegate, Raymond A

    2008-04-01

    To report the development of a tool designed to dynamically simulate the effect of soft toric contact lens movement on retinal image quality, initial findings on three eyes, and the next steps to be taken to improve the utility of the tool. Three eyes of two subjects wearing soft toric contact lenses were cyclopleged with 1% cyclopentolate and 2.5% phenylephrine. Four hundred wavefront aberration measurements over a 5-mm pupil were recorded during soft contact lens wear at 30 Hz using a complete ophthalmic analysis system aberrometer. Each wavefront error measurement was input into Visual Optics Laboratory (version 7.15, Sarver and Associates, Inc.) to generate a retinal simulation of a high contrast log MAR visual acuity chart. The individual simulations were combined into a single dynamic movie using a custom MatLab PsychToolbox program. Visual acuity was measured for each eye reading the movie with best cycloplegic spectacle correction through a 3-mm artificial pupil to minimize the influence of the eyes' uncorrected aberrations. Comparison of the simulated acuity was made to values recorded while the subject read unaberrated charts with contact lenses through a 5-mm artificial pupil. For one study eye, average acuity was the same as the natural contact lens viewing condition. For the other two study eyes visual acuity of the best simulation was more than one line worse than natural viewing conditions. Dynamic simulation of retinal image quality, although not yet perfect, is a promising technique for visually illustrating the optical effects on image quality because of the movements of alignment-sensitive corrections.

  11. Intraocular Inflammation Associated with Ocular Toxoplasmosis : Relationships at Initial Examination

    NARCIS (Netherlands)

    Dodds, Emilio M.; Holland, Gary N.; Stanford, Miles R.; Yu, Fei; Siu, Willie O.; Shah, Kayur H.; Loon, Ninette Ten Dam-Van; Muccioli, Cristina; Hovakimyan, Anna; Barisani-Asenbauer, Talin

    2008-01-01

    PURPOSE: To describe characteristics of intraocular inflammation in eyes with active ocular toxoplasmosis and to identify relationships between signs of inflammation, complications (including elevated intraocular pressure [IOP]), other disease features, and host characteristics. DESIGN: Multicenter,

  12. Effect of plasma colloid osmotic pressure on intraocular pressure during haemodialysis

    OpenAIRE

    Tokuyama, T.; Ikeda, T.; Sato, K.

    1998-01-01

    BACKGROUND—In a previous case report, it was shown that an increase in plasma colloid osmotic pressure induced by the removal of fluid during haemodialysis was instrumental in decreasing intraocular pressure. The relation between changes in intraocular pressure, plasma osmolarity, plasma colloid osmotic pressure, and body weight before and after haemodialysis is evaluated.
METHODS—Intraocular pressure, plasma osmolarity, plasma colloid osmotic pressure, and body weight were evaluated before a...

  13. Severe pigment dispersion after iris-claw phakic intraocular lens implantation.

    Science.gov (United States)

    Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N

    2017-12-01

    A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  14. Severe pigment dispersion after iris-claw phakic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Virgilio Galvis

    2017-01-01

    Full Text Available A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  15. Fundus autofluorescence patterns in primary intraocular lymphoma.

    Science.gov (United States)

    Casady, Megan; Faia, Lisa; Nazemzadeh, Maryam; Nussenblatt, Robert; Chan, Chi-Chao; Sen, H Nida

    2014-02-01

    To evaluate fundus autofluorescence (FAF) patterns in patients with primary intraocular (vitreoretinal) lymphoma. Records of all patients with primary intraocular lymphoma who underwent FAF imaging at the National Eye Institute were reviewed. Fundus autofluorescence patterns were evaluated with respect to clinical disease status and the findings on fluorescein angiography and spectral-domain optical coherence tomography. There were 18 eyes (10 patients) with primary intraocular lymphoma that underwent FAF imaging. Abnormal autofluorescence in the form of granular hyperautofluorescence and hypoautofluorescence was seen in 11 eyes (61%), and blockage by mass lesion was seen in 2 eyes (11%). All eyes with granular pattern on FAF had active primary intraocular lymphoma at the time of imaging, but there were 5 eyes with unremarkable FAF, which were found to have active lymphoma. The most common pattern on fluorescein angiography was hypofluorescent round spots with a "leopard spot" appearance (43%). These hypofluorescent spots on fluorescein angiography correlated with hyperautofluorescent spots on FAF in 5 eyes (36%) (inversion of FAF). Nodular hyperreflective spots at the level of retinal pigment epithelium on optical coherence tomography were noted in 43% of eyes. The hyperautofluorescent spots on FAF correlated with nodular hyperreflective spots on optical coherence tomography in 6 eyes (43%). Granularity on FAF was associated with active lymphoma in majority of the cases. An inversion of FAF (hyperautofluorescent spots on FAF corresponding to hypofluorescent spots on fluorescein angiography) was observed in less than half of the eyes.

  16. Aderência in vitro do Staphylococcus epidermidis e da Pseudomonas alcaligenes em lentes intra-oculares In vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to intraocular lenses

    Directory of Open Access Journals (Sweden)

    Patrícia Ioschpe Gus

    2006-06-01

    Full Text Available OBJETIVO: Quantificar e comparar a aderência in vitro das bactérias Staphylococcus epidermidis e Pseudomonas alcaligenes em diferentes tipos de lentes intra-oculares (LIOs. MÉTODOS: Quatorze lentes intra-oculares foram usadas no experimento. Quatro de polimetilmetacrilato (PMMA, quatro de silicone, quatro de hidrogel e duas de acrílico. Oito lentes intra-oculares foram colocadas em oito tubos de ensaio contendo 4 ml de suspensão de Pseudomonas alcaligenes, e seis lentes intra-oculares foram colocadas em seis tubos de ensaio contendo 4 ml de suspensão de Staphylococcus epidermidis. A concentração do caldo utilizada para o teste de aderência foi de 10(8 unidades formadoras de colônias por mililitro (CFU/mL que corresponde a 0,5 na escala de McFarland. As lentes foram incubadas a 37° por duas horas. Após, foram removidas dos caldos e enxaguadas em água destilada estéril por duas vezes. As lentes foram cultivadas em placas de ágar-sangue a 35-37° e evaliadas a cada 24h por um período de 72h. Nas amostras que tiveram crescimento bacteriano, foram contadas as colônias utilizando os métodos convencionais de laboratório. Todos os ensaios foram executados em duplicata. RESULTADOS: A aderência do Staphylococcus epidermidis nas lentes de PMMA foi menor se comparada com as de silicone e de hidrogel. A aderência daPseudomonas alcaligenes nas lentes de hidrogel foi menor se comparada com as de silicone, PMMA e acrílico. CONCLUSÃO: Os resultados sugerem que a aderência do Staphylococcus epidermidis e da Pseudomonas alcaligenes nas lentes intra-oculares é influenciada pelo tipo de material da lente e pela espécie do microorganismo. A aderência bacteriana pode ter papel importante na patogenicidade da endoftalmite pós-cirurgia de catarata.PURPOSE: To quantify and compare the in vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to different intraocular lenses (IOLs. METHODS: Fourteen intraocular lenses were

  17. WHAT HAPPENS TO INTRAOCULAR PRESSURE AFTER PERIBULBAR ANAESTHESIA?

    Directory of Open Access Journals (Sweden)

    Krishnamoorthy Segharipuram Ranganathan

    2017-08-01

    Full Text Available BACKGROUND Most of intraocular surgeries are done under local anaesthesia. The peribulbar anaesthesia provides adequate anaesthesia and akinesia. There is no reported intraoperative and/or postoperative amaurosis. The peribulbar anaesthesia provides adequate anaesthesia and akinesia. The disadvantages of it are the larger quantity of the aesthetic agent. Increasing the bulk load on the globe and a reported rise of intraocular pressure. MATERIALS AND METHODS A study of fifty cases was conducted in patients who received peribulbar anaesthesia undergoing cataract extraction with intraocular lens implantation and their intraocular pressures were noted and studied after giving the peribulbar anaesthesia all given by the same surgeon. RESULTS This study did show that the peribulbar anaesthesia increases the intraocular pressure in all the cases. The external ocular compression indeed helps to dissipate the anaesthetic load thereby reducing the enormous rise in IOP, which is only expected if you recollect the fact that the eyeball occupies one sixth of the total volume of the orbit that is 5 mL and 30 mL. The volume of peribulbar anaesthesia (6 mL does add its effects to increase the IOP. Hence, a properly planned post peribulbar compression helps to minimise the transient rise in IOP. CONCLUSION Summarising the study, it is better to give peribulbar injection initially followed by external ocular compression after a delay of at least 2 to 5 minutes. It is also advised that an initial compression maybe given in slightly risk cases, so that the peribulbarinduced rise may not be alarming. The anaesthetic solution maybe fragmented and the second injection maybe delayed by 5 minutes or omitted if good akinesia and anaesthesia are achieved already.

  18. Visual outcome with the Oculentis Mplus intraocular lens

    OpenAIRE

    Si-Yuan Liu; Xu Yang

    2017-01-01

    AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL).METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOL)were as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications. RESULTS: At ...

  19. Towards customized intraocular lenses

    NARCIS (Netherlands)

    de Jong, Tim

    2017-01-01

    In the eye there are two refractive components that make light focus on the retina and let you see: the cornea and the lens. When a eye develops cataract the lens becomes caractarous and is removed and replaced with a synthetic intraocular lens during a cataract surgery procedure. Although there was

  20. Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2012-10-01

    Full Text Available PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes received ultraviolet and blue light filter (yellow tinted IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD] investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

  1. Clinical study on the incidence of vancomycin intraocular injection in treatment with suppurative endophthalmitis

    Directory of Open Access Journals (Sweden)

    Yi-Qin Duan

    2015-05-01

    Full Text Available AIM:To estimate the clinical significance of the microculture of humor and vitreous and vancomycin intraocular injection in treatment of suppurative endophthalmitis associated with intraocular foreign bodies.METHODS: Totally 65 patients with penetrating eye trauma and retained intraocular foreign bodies in emergency operation and intraocular injection from January 2012 to September 2014 were regarded as the study group, another 62 patients with penetrating eye trauma and retained intraocular foreign bodies in emergency operation without intraocular injection before August 2011 were regarded as the control group. Aqueous humor and vitreous humor were taken from each patient of the study group and the control group for bacteria and fungus cultivation. The study group was treated with 1mg vancomycin intraocular injection after operation, while the control group was not. RESULTS: The incidence of endophthalmitis in the control group was 16%(10 cases, while in the study group was 3%(2 cases, with significant difference between two groups(x2=6.32, PP>0.05. The positive rate of vitreous humor germiculture in study group was 14%(9 cases, and the incidence of endophthalmitis was 3%. The positive rate of vitreous humor germiculture in control group was 11%(7 casesand the incidence of endophthalmitis was 16%, with significant differences between two groups(PCONCLUSION: Intraocular foreign bodies treated with emergency operation and vancomycin intraocular injections can decrease the incidence of suppurative endophthalmitis and have a good vision prognosis for the second stage of operation.

  2. Survey of Intraocular Antibiotics Prophylaxis Practice after Open Globe Injury in China.

    Directory of Open Access Journals (Sweden)

    Bingsheng Lou

    Full Text Available To elucidate the Chinese practice of intraocular antibiotics administration for prophylaxis after open globe injury.A cross-sectional questionnaire survey was performed online by scanning a Quickmark (QR code with smartphones at the 20th Chinese National Conference of Ocular Trauma in November 2014.A total of 153 (30.6% of all participators at the conference responded. Of the respondents, 20.9% were routinely administered with prophylactic intraocular injection of antibiotics at the conclusion of the primary eye repair, and 56.9% were used only in cases with high risk of endophthalmitis development. The intraocular route of delivery was mainly included with intracameral injection (47.9% and intravitreal injection (42.0%. Cephalosporins (53.8% and vancomycin (42.0% were the main choices of antibiotic agents, followed by fluoroquinolones (24.3%, and aminoglycosides (13.4%. Only 21.9% preferred a combination of two or more two drugs routinely. In addition, significantly more respondents from the referral eye hospital (92.7% replied using intraocular antibiotics injection for prophylaxis compared to those respondents from the primary hospital (69.4% (p = 0.001, Fisher's exact test.Intraocular antibiotics injection for post-traumatic endophthalmitis prophylaxis is widely used in China. However, the choice of antibiotic agents and the intraocular route of delivery vary. A well-designed clinical trial is needed to establish a standardized protocol of intraocular antibiotics administration for post-traumatic endophthalmitis prophylaxis.

  3. Mean intraocular pressure in hypertensive adults

    International Nuclear Information System (INIS)

    Irum, S.; Malik, A.M.; Saeed, M.

    2015-01-01

    To determine the mean Intraocular Pressure (IOP) in already diagnosed adult hypertensive patients with different grades of hypertension. Study Design: Cross-sectional descriptive study. Place and Duration of Study: Combined Military Hospital, Lahore, from March 2012 to Aug 2012. Patients and Methods: A total of 178 already diagnosed hypertensive patients were selected. A detailed history of ocular or systemic diseases was taken. Intraocular pressure was measured with help of Goldmann applanation tonometer. Three consecutive readings of IOP of each eye were taken at 30 minutes interval and mean calculated. Blood pressure was recorded in seated position from right upper arm, by mercury sphygmomanometer. Blood pressure measurements were determined by taking the mean value of three systolic and diastolic readings. Results: The results of intraocular pressure (IOP) between various grades of hypertension were determined. There was an increase in mean IOP with rise in blood pressure. The subjects with grade I hypertension showed a mean IOP of 13.95 ± 3.74 mmHg, while grade II and grade III hypertensive subjects had mean IOPs as 18.10 ± 3.32 and 20.21 ± 2.52 mmHg respectively. Conclusion: A higher value of mean IOP was found with increase in systolic and diastolic blood pressures. (author)

  4. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    Science.gov (United States)

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  5. Intraocular pressure variations during zygomatic fracture reduction and fixation: a clinical study.

    LENUS (Irish Health Repository)

    Murray, Dylan J

    2012-02-03

    BACKGROUND: The reduction of midface fractures has been associated with the rare but devastating complication of blindness. An increase in intraocular pressure is important in the mechanism of blindness in this setting. In this study, the authors assessed the intraocular pressure in patients who underwent zygomatic fracture reduction (with or without fixation). METHODS: Using applanation tonometry, 29 patients underwent intraocular pressure measurements before, during, and after fracture fixation. The contralateral pressures were measured and used as the control. RESULTS: There were 29 patients with a mean age of 35 years, and the mean time to surgery was 5 days. Preoperatively, all patients had normal intraocular pressures and normal visual acuity. All patients underwent a Gillies lift and 18 patients required open reduction and fixation of the frontozygomatic suture (n = 4) or the infraorbital margin (n = 2), and the remainder (n = 12) required fixation of both points. There was no statistically significant increase in the intraocular pressures following the reduction of uncomplicated zygomatic fractures. Statistically significant pressure reductions were noted immediately after reduction and fixation. CONCLUSIONS: The surgical reduction of uncomplicated zygomatic fractures has no adverse effect on the intraocular pressure. It is the authors\\' opinion that adjunctive measures to reduce the pressures are unnecessary.

  6. Topical tissue plasminogen activator appears ineffective for the clearance of intraocular fibrin.

    Science.gov (United States)

    Zwaan, J; Latimer, W B

    1998-06-01

    To determine the efficacy of topical tissue plasminogen activator (tPA) for the resolution of postoperative or inflammatory intraocular fibrinous exudates. Each treatment consisted of drops of 1 mg/ml tPA given 9 times 5 minutes apart. Records were reviewed and the results at 24 and 48 hours were recorded. Sixty-two patients had a total of 94 treatments. Fibrin exudates following intraocular surgery in 34 patients were treated 44 times. In 6 patients there was a positive result. Fibrin associated with intraocular infection was treated in 9 patients. None showed clear improvement. Nineteen patients had a total of 34 treatments for poorly controlled intraocular pressure (IOP) after glaucoma surgery. Five patients showed adequate control of the IOP, 12 did not change, and 2 had a questionable improvement. Eleven patients had adequate IOP control after additional treatment. Seven required suture lysis, 2 ab interno bleb revision, and 2 YAG capsulotomy or iridotomy to reduce the IOP to an acceptable level. Within the limits of this retrospective study and taking into account that fibrin may resolve spontaneously, it appears that topical tPA drops are not effective for the liquefaction of intraocular fibrin after surgery or in association with intraocular inflammation. They did not improve IOP control after glaucoma surgery.

  7. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  8. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant

    Directory of Open Access Journals (Sweden)

    Clara Ye

    2018-06-01

    Full Text Available Purpose: We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL (Visian ICL™, Staar Inc., Monrovia, CA implant that resulted in advanced visual field loss. Observations: A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Conclusions and importance: Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss. Keywords: Phakic intraocular lens, Intraocular collamer lens, Pigment dispersion, Glaucoma

  9. Assessment of intraocular foreign bodies by helical-CT multiplanar imaging

    International Nuclear Information System (INIS)

    Papadopoulos, A.; Fotinos, A.; Maniatis, V.; Kavadias, S.; Michaelides, A.; Avouri, M.; Kalamara, C.; Stringaris, K.

    2001-01-01

    The aim of this study was to examine the effectiveness of helical CT in the assessment of intraocular foreign bodies, evaluating two protocols with different collimation. We performed helical-CT studies in 30 patients. Fifteen patients were examined with 1.5-mm collimation and the other 15 patients with 3.0-mm collimation. All other imaging parameters were identical in both protocols. Multiplanar images were reconstructed. The examinations were reviewed for presence, localization and size of intraocular foreign bodies. We compare our results with the surgical data. We estimate the required examination time. In the first group (collimation 1.5 mm) an intraorbital foreign body was detected in 8 of 15 patients. In 3 of 8 patients an intraocular foreign body (all were metallic) was detected. In the second group (collimation 3.0 mm) an intraorbital foreign body was detected in 9 of 15 patients. In 8 of 9 patients an intraocular foreign body (all were metallic) was detected. Our results were confirmed by surgery in all cases. Examination time was 36 s in the first group and 18 s in the second group. Computed tomography should be considered the imaging modality of choice in the assessment of metallic intraocular foreign bodies and 3.0-mm collimation is optional, because of reduced examination time and radiation exposure. (orig.)

  10. A novel clinical sign in intraocular tuberculosis: Active chorioretinitis within chorioretinal atrophy

    OpenAIRE

    Avinash Pathengay; Bhavik Panchal; Himadri Choudhury; Soumyava Basu; Nidhi Relhan; Harry W. Flynn, Jr.

    2017-01-01

    Purpose: To report a novel clinical sign in patients with intraocular tuberculosis. The current study is an observational consecutive case series of patients diagnosed with intraocular tuberculosis managed at a tertiary eye care centre from June 1, 2012 to December 31, 2015. Observations: The diagnosis of intraocular tuberculosis was made in 6 patients based on ocular features suggestive of tuberculosis along with a positive tuberculin skin testing and chest X-ray consistent with tuberculo...

  11. Modeling of EAST ICRF antenna performance using the full-wave code TORIC

    Energy Technology Data Exchange (ETDEWEB)

    Edlund, E. M., E-mail: eedlund@pppl.gov [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Bonoli, P. T.; Porkolab, M.; Wukitch, S. J. [MIT Plasma Science and Fusion Center, Cambridge, MA (United States)

    2015-12-10

    Access to advanced operating regimes in the EAST tokamak will require a combination of electron-cyclotron resonance heating (ECRH), neutral beam injection (NBI) and ion cyclotron range frequency heating (ICRF), with the addition of lower-hybrid current drive (LHCD) for current profile control. Prior experiments at the EAST tokamak facility have shown relatively weak response of the plasma temperature to application of ICRF heating, with typical coupled power about 2 MW out of 12 MW source. The launched spectrum, at n{sub φ} = 34 for 0-π -0-π phasing and 27 MHz, is largely inaccessible at line-averaged densities of approximately 2 × 10{sup 19} m{sup −3}. However, with variable antenna phasing and frequency, this system has considerable latitude to explore different heating schemes. To develop an ICRF actuator control model, we have used the full-wave code TORIC to explore the physics of ICRF wave propagation in EAST. The results presented from this study use a spectrum analysis using a superposition of n{sub φ} spanning −50 to +50. The low density regime typical of EAST plasmas results in a perpendicular wavelength comparable to the minor radius which results in global cavity resonance effects and eigenmode formation when the single-pass absorption is low. This behavior indicates that improved performance can be attained by lowering the peak of the k{sub ||} spectrum by using π/3 phasing of the 4-strap antenna. Based on prior studies conducted at Alcator C-Mod, this phasing is also expected to have the advantage of nearly divergence-free box currents, which should result in reduced levels of impurity production. Significant enhancements of the loading resistance may be achieved by using low k{sub ||} phasing and a combination of magnetic field and frequency to vary the location of the resonance and mode conversion regions. TORIC calculations indicate that the significant power may be channeled to the electrons and deuterium majority. We expect that

  12. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

    Science.gov (United States)

    Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P

    2012-03-01

    To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the

  13. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer].

    Science.gov (United States)

    Chen, X; Peng, D; Zhou, W; Zhong, Y

    1995-06-01

    To evaluate the accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer. 58 patients' (113 eyes) intraocular pressure were measured by Keeler, non-contact tonometer and R 900 Goldmann applanation tonometer and the results of measurement of intraocular pressure by the two kinds of tonometers were compared. The mean intraocular pressure measured by non-contact is 16.31 +/- 5.59 mmHg and 17.49 +/- 6.13 mmHg (1 mmHg = 0.1333 kPa) by Goldmann applanation tonometer, respectively. There was no statistical significance to be found (P > 0.05) between the two methods. By linear correlation and regression analysis, a positive correlation was found between the two methods (r = 0.8942, b = 0.8154). The handheld non-contact tonometer has the same accuracy and reliability of measurement of intraocular pressure comparing with Goldmann applanation tonometer, and it can be used in glaucoma clinic and screening.

  14. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens.

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. The mean follow-up was 23 months (range: 6-48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context of a surgery usually indicated in

  15. Flurbiprofen and intraocular pressure.

    Science.gov (United States)

    Gieser, D K; Hodapp, E; Goldberg, I; Kass, M A; Becker, B

    1981-07-01

    Systemic or topical administration of corticosteroids may produce a rise in intraocular pressure (IOP). Nonsteroidal anti-inflammatory drugs (NSAI drugs) are alternate therapy for ocular inflammatory disease. Flurbiprofen, a new NSAI drug, was tested in double-masked fashion to delineate its effect on IOP. Flurbiprofen did not alter IOP in known high corticosteroid responders nor did it block corticosteroid-induced ocular hypertension.

  16. Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

    Science.gov (United States)

    Pandey, Suresh K; Apple, David J

    2005-06-01

    Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

  17. Delayed diagnosis of homocystinuria presenting as bilateral congenital lens subluxation

    Directory of Open Access Journals (Sweden)

    Jelić-Vuković Marija

    2017-01-01

    Full Text Available Introduction. Homocystinuria is an autosomal recessively inherited defect leading to hyperhomocysteinemia and associated with ocular manifestations, mainly myopia and ectopia lentis. Case outline. A 26-year-old male with secondary glaucoma due to bilateral lens subluxation was admitted to the Department of vitreoretinal surgery. Horizontal nystagmus, bilateral lens subluxation, and bilateral amblyopia were first discovered at the age of three years. Preoperative laboratory workup revealed elevated levels of homocysteine. Bilateral pars plana lensectomy and vitrectomy followed by a sulcus fixation of the intraocular lens (ALCON MA60 Acrysof IOL were performed. The patient was prescribed folic acid, methionine, and pyridoxine, and was urged to maintain a methionine-low diet. After a bilateral lensectomy and sulcus fixation of the intraocular lens and a methionine restriction therapy combined with vitamin B6, B9, and B12 supplementation, his condition improved greatly. Conclusion. In this report of a rare case we emphasize the importance of examining differential diagnoses of lens subluxation, since early intervention can prevent serious complications.

  18. Experiencia con la lente intraocular RAYNER 620H Experience gained with the use of intraocular lens RAYNER 620 H

    Directory of Open Access Journals (Sweden)

    Juan Raúl Hernández Silva

    2008-06-01

    Full Text Available Un importante eslabón en el progreso alcanzado en la cirugía de cataratas, está fundamentado en el desarrollo industrial paralelo que ha ocurrido durante los últimos años con la introducción de nuevos modelos de lentes intraoculares, como el Rayner 620 H; el perfeccionamiento del instrumental quirúrgico, sistemas de aspiración e irrigación bimanual y bisturí con la medida exacta para colocar el inyector de la lente intraocular. La lente intraocular Rayner 620H significó un gran paso para la facoemulsificación y el control de la opacidad de la cápsula posterior posoperatoria por el diseño peculiar de su óptica y hápticos, que permiten un implante seguro, fácil y una incisión mínima. Se realizó un estudio prospectivo y descriptivo, cuyo universo de estudio fueron 28 ojos con diagnóstico de cataratas a los cuales se les realizó facoemulsificación con implante de lente intraocular Rayner 620 H, en el Centro de Microcirugía Ocular del Instituto Cubano de oftalmología "Ramón Pando Ferrer" en el período comprendido entre junio de 2006 a febrero de 2007. El grupo de edades donde se encontró el de mayor número de pacientes fue en el de más de 60 años. En todos los casos hubo un aumento significativo de la agudeza visual sin corrección y con ella, del preoperatorio al posoperatorio. Hubo un aumento del cilindro queratométrico del preoperatorio al posoperatorio, pero este fue mínimo La pérdida de células endoteliales fue baja del preoperatorio al posoperatorio, respectivamente. No hubo ninguna complicación durante la cirugía ni después de esta. Evaluamos como satisfactoria la efectividad del lente intraocular Rayner 620 H, por el aumento de la agudeza visual del paciente, el bajo astigmatismo inducido, mejoría del campo visual por confrontación, mínima pérdida de células endoteliales, y ausencia de complicaciones y de deslumbramiento posoperatorio en los pacientes.An important link in the advances made by the

  19. Intraocular pressure in very low birth weight preterm infants and its association with postconceptional age

    Directory of Open Access Journals (Sweden)

    Rodrigo L. Lindenmeyer

    2012-11-01

    Full Text Available OBJECTIVE: To evaluate intraocular pressure in very low birth weight preterm infants and correlate it with postconceptional age. METHODS: The intraocular pressure in a prospective cohort of very low birth weight premature infants (defined as a birth weight <1,500 g and gestational age <32 weeks admitted to Hospital de Clínicas de Porto Alegre , Brazil was evaluated weekly. The evaluated outcome was the variation in the intraocular pressure following changes in the postconceptional age (defined as the gestational age at birth plus the age in weeks at the time of examination in the weeks following preterm birth. Mixed-effects models were used for the statistical analysis to determine the intraocular pressure variation according to postconceptional age, and means and 10th and 90th percentiles were calculated for the intraocular pressure values. RESULTS: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and a mean birth weight of 1,127.7 ± 222.7 g were evaluated. The mean intraocular pressure for the entire cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of all recorded intraocular pressure values were greater than 20 mmHg. The analysis revealed a mean reduction in the intraocular pressure of 0.29 mmHg for each increase in postconceptional age (p = 0.047; 95% CI: -0.58 to -0.0035. The mean intraocular pressure (P10-P90 decreased from 16.3 mmHg (10.5222.16 at 26.3 weeks to 13.1 mmHg (7.28-18.92 at 37.6 weeks of postconceptional age. CONCLUSIONS: The mean intraocular pressure in very low birth weight preterm infants was 14.9 ± 4.5 mmHg. This value decreased 0.29 mmHg per week as the postconceptional age increased.

  20. Intraocular manifestations of mycobacterium tuberculosis: A review of the literature

    Directory of Open Access Journals (Sweden)

    Lauren A. Dalvin

    2017-05-01

    Full Text Available Mycobacterium tuberculosis: is most commonly associated with pulmonary infection. However, tuberculosis (TB can also affect the eye. TB can affect nearly any tissue in the eye, and a high index of suspicion is required for accurate diagnosis, as many of the intraocular manifestations of TB can mimic other, more common diseases. Correct diagnosis is critical because systemic anti-tuberculosis treatment may be required, and vision loss or even loss of the affected eye can occur without proper treatment. Thus, it is important for ophthalmologists and infectious disease specialists to work together to accurately diagnose and treat intraocular TB. This article reports the various known presentations of intraocular TB and reviews important elements of diagnosis and treatment. Keywords: Mycobacterium, Tuberculosis, Choroidal granuloma, Retinal vasculitis

  1. Epithelial Downgrowth after Intraocular Surgery Treated with Intracameral 5-Fluorouracil

    Directory of Open Access Journals (Sweden)

    Nina Ni

    2015-01-01

    Full Text Available Purpose. To present the clinical and histopathologic correlation of two cases of epithelial downgrowth (EDG after prior intraocular surgery. Methods. Observational case reports. Results. We present two cases of EDG occurring after intraocular surgery. In both cases, after two anterior chamber injections of 5-fluorouracil (5FU, the area of EDG initially regressed. In Case 1, a limited area of EDG eventually recurred, and penetrating keratoplasty with cryotherapy was curative. In Case 2, subsequent corneal edema required Descemet-stripping automated endothelial keratoplasty, and the patient remained clinically free of EDG without further treatment. Conclusion. Intracameral 5FU may have a role in the treatment of EDG after intraocular surgery, though its precise utilization and impact remain to be defined.

  2. Comparison between intraocular pressure spikes with water loading and postural change.

    Science.gov (United States)

    Chong, Calum Wk; Wang, Sarah B; Jain, Neeranjali S; Bank, Cassandra S; Singh, Ravjit; Bank, Allan; Francis, Ian C; Agar, Ashish

    2016-12-01

    To compare the agreement between peak intraocular pressures measured through the water drinking test and the supine test, in patients with primary open angle glaucoma. Consecutive, prospective, blinded. Twenty-one patients from the Glaucoma Unit, Prince of Wales Hospital, Sydney, Australia. For the supine test, intraocular pressure was recorded immediately after the patient had lain down and at 20 and 40 min. At the second evaluation, intraocular pressure was measured in each patient after drinking 10 mL/kg body weight of water for the water drinking test. Again, all patients had their intraocular pressure measured at 20 and 40 min (t = 20 and t = 40, respectively). Patients were excluded from the study if they had pre-existing cardiac, renal or pulmonary complications or had concurrent ocular disease or an anatomical abnormality (including angle recession, peripheral anterior synechiae and developmental anomalies of the angle) that may have influenced intraocular pressure. Bland-Altman analysis. Bland-Altman analysis indicated an overall excellent agreement in terms of mean difference between methods (1.0, -1.0 and -0.90 mmHg, at 0, 20 and 40 min, respectively). Further, with the exception of t = 40, all measured time points had 95% confidence intervals within 6.5 mmHg of their mean difference on the Bland-Altman plot. There was close agreement between the intraocular pressure values of the supine test and water drinking test. However, as the water drinking test may be uncomfortable and potentially hazardous, there is potential that the supine test may be a safer and more comfortable alternative. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  3. A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    Directory of Open Access Journals (Sweden)

    Korenfeld MS

    2016-01-01

    Full Text Available Michael S Korenfeld,1,2 David K Dueker3 1Comprehensive Eye Care, Ltd., 2Department of Ophthalmology and Visual Sciences, Washington University, Washington, MO, USA; 3Hamad Medical Corporation, Doha, Qatar Purpose: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulated eyes. Methods: A thin fluid-filled bladder was constructed from flexible and inelastic plastic sheeting and was connected to a pressure transducer with high pressure tubing. The output of the pressure transducer was sent to an amplifier and recorded. This device was validated by measuring induced pressure in the fluid-filled bladder while digital pressure was applied to one surface, and the other surface was placed directly against a human cadaver eye or in vivo pig eye. The human cadaver and in vivo pig eyes were each cannulated to provide a manometric intraocular pressure control. Results: The measurements obtained with the newly described device were within ~5% of simultaneously measured manometric intraocular pressures in both a human cadaver and in vivo pig eye model for a pressure range of ~15–100 mmHg. Conclusion: This novel noninvasive device is useful for estimating the intraocular pressure transients induced during any form of external globe compression; this is a clinical setting where no other devices can be used to estimate intraocular pressure. Keywords: glaucoma, intraocular pressure, tonometer, ocular compression

  4. Do evidence-based guidelines change clinical practice patterns?

    DEFF Research Database (Denmark)

    Kessel, Line; Erngaard, Ditte; Flesner, Per

    2017-01-01

    In 2013, the Danish Health and Medicines Authorities published a National Clinical Guideline on the treatment of age-related cataracts. The guideline provided evidence-based recommendations on the indication for cataract surgery, cataract surgery in patients with age-related macular degeneration......, on the use of toric intraocular lenses (IOLs) to correct preoperative corneal astigmatism, the use of intracameral and topical antibiotics to prevent endophthalmitis, choice of anti-inflammatory medication to control postoperative inflammation and prevent cystoid macular oedema, the use of immediate...

  5. Posterior Segment Intraocular Foreign Body: Extraction Surgical Techniques, Timing, and Indications for Vitrectomy

    Directory of Open Access Journals (Sweden)

    Dante A. Guevara-Villarreal

    2016-01-01

    Full Text Available Ocular penetrating injury with Intraocular Foreign Body (IOFB is a common form of ocular injury. Several techniques to remove IOFB have been reported by different authors. The aim of this publication is to review different timing and surgical techniques related to the extraction of IOFB. Material and Methods. A PubMed search on “Extraction of Intraocular Foreign Body,” “Timing for Surgery Intraocular Foreign Body,” and “Surgical Technique Intraocular Foreign Body” was made. Results. Potential advantages of immediate and delayed IOFB removal have been reported with different results. Several techniques to remove IOFB have been reported by different authors with good results. Conclusion. The most important factor at the time to perform IOFB extraction is the experience of the surgeon.

  6. Bacillus cereus panophthalmitis associated with intraocular gas bubble.

    Science.gov (United States)

    al-Hemidan, A; Byrne-Rhodes, K A; Tabbara, K F

    1989-01-01

    It has become increasingly apparent that Bacillus cereus can cause a severe and devastating form of endophthalmitis following penetrating trauma by a metallic object. B. cereus is an uncommon aetiological agent in non-clostridial gas-forming infections. The patient studied in this single case report showed evidence of intraocular gas mimicking gas gangrene infection. The physiology of non-clostridial bacteria producing gas from anaerobic metabolic conditions is reviewed. Further intraocular and systemic complications which may be avoided by accurate and early diagnosis and the use of recommended treatment with antibiotics such as clindamycin. Images PMID:2493262

  7. Influence of macular pigment optical density spatial distribution on intraocular scatter.

    Science.gov (United States)

    Putnam, Christopher M; Bland, Pauline J; Bassi, Carl J

    This study evaluated the summed measures of macular pigment optical density (MPOD) spatial distribution and their effects on intraocular scatter using a commercially available device (C-Quant, Oculus, USA). A customized heterochromatic flicker photometer (cHFP) device was used to measure MPOD spatial distribution across the central 16° using a 1° stimulus. MPOD was calculated as a discrete measure and summed measures across the central 1°, 3.3°, 10° and 16° diameters. Intraocular scatter was determined as a mean of 5 trials in which reliability and repeatability measures were met using the C-Quant. MPOD spatial distribution maps were constructed and the effects of both discrete and summed values on intraocular scatter were examined. Spatial mapping identified mean values for discrete MPOD [0.32 (s.d.=0.08)], MPOD summed across central 1° [0.37 (s.d.=0.11)], MPOD summed across central 3.3° [0.85 (s.d.=0.20)], MPOD summed across central 10° [1.60 (s.d.=0.35)] and MPOD summed across central 16° [1.78 (s.d.=0.39)]. Mean intraocular scatter was 0.83 (s.d.=0.16) log units. While there were consistent trends for an inverse relationship between MPOD and scatter, these relationships were not statistically significant. Correlations between the highest and lowest quartiles of MPOD within the central 1° were near significance. While there was an overall trend of decreased intraocular forward scatter with increased MPOD consistent with selective short wavelength visible light attenuation, neither discrete nor summed values of MPOD significantly influence intraocular scatter as measured by the C-Quant device. Published by Elsevier España, S.L.U.

  8. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  9. The Effect of Various Contact Lenses on Intraocular Pressure Measurement by Goldman Tonometer

    Directory of Open Access Journals (Sweden)

    Monireh Mahjoob

    2014-06-01

    Full Text Available Background: Today, contact lenses have extensive usages. Contact lens places on cornea, so it may induce variation on cornea and these variations can influence the measurement of intraocular pressure (IOP by Goldman tonometer. The aim of this research was to study the effect of various contact lenses on measurement of intraocular pressure by Goldman tonometer. Materials and Methods: In this study, 80 subjects aged 18-25 were selected randomly among patients of Al-Zahra ophthalmology center. None of them has any eye pathological problems. Before wearing the lens, intraocular pressure was measured, and then patients were divided into two groups of soft and hard contact lenses. Soft and hard contact lenses were placed on the eye for two hours, and the intraocular pressure was measured again. Results: The mean of IOP before wearing contact lenses and two hours later was 15.96 mmHg and 13.93, s respectively. Paired test showed a significant difference between IOP before and after wearing contact lenses (p=0.001.There was no significant differences in mean of intraocular pressure decline before and after placing the contact lens in both soft and hard lenses. Conclusion: According to this study, the intraocular pressure decreases after wearing contact lenses (CL. This decline may be due to variation in properties of cornea after wearing CL that can also affect IOP measurement.

  10. Phakic Intraocular Lens Implantation: Refractive Outcome and Safety in Patients with Anterior Chamber Depth between 2.8 and 3.0 versus ≥3.0 mm.

    Science.gov (United States)

    Guerra, Marta G; Silva, Andreia M M; Marques, Sara H M; Melo, Sofia H; Póvoa, João A; Lobo, Conceição; Murta, Joaquim Neto

    2017-01-01

    To compare endothelial cell (EC) variation after anterior chamber phakic intraocular lens (AC-pIOL) implantation in highly myopic patients with a preoperative anterior chamber depth (ACD) between 2.8 and 3.0 versus ≥3.0 mm. A total of 280 eyes submitted to primary AC-pIOL implantation were analyzed. Pre- and postoperative values for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, ACD (endothelial surface), and EC count were collected. The eyes were divided into 2 groups: group A - ACD between 2.8 and 3.0 mm; group B - ACD ≥3.0 mm. Mean global EC loss (ECL) and loss for each ACD group, according to pIOL type, were analyzed. Significant improvement of the spherical equivalent (-11.38 ± 4.57 vs. -0.49 ± 0.79; p = 0.000) and a significant decrease in EC density (2,810.95 ± 343.88 vs. 2,584.09 ± 374.88 cells/mm2; p = 0.000) were noted. The mean annual ECL was -2.19 ± 3.97%. Regarding group A (n = 80), a mean annual ECL of -2.06 ± 3.88% was registered, higher for the Acrysof Cachet® subtype, while group B (n = 200) showed -2.25 ± 4.01% ECL, higher for the Verisyse® subtype. There was no significant difference between the groups (p = 0.96). AC-pIOL implantation significantly improves the spherical equivalent in myopic patients. The mean annual ECL after pIOL implantation was higher in the larger ACD group, but this value was not statistically significant. A 2.8-mm ACD value seems to be a safe cutoff for AC-pIOL implantation. © 2017 S. Karger AG, Basel.

  11. Magnetic resonance imaging diagnosis of intraocular lenses. Die kernspintomographische Diagnostik der Hinterkammerlinse

    Energy Technology Data Exchange (ETDEWEB)

    Tosch, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Bleckmann, H. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Kaczmarek, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany))

    1994-09-01

    Intraocular lenses were investigated by MRI to obtain information about the quality of this method. In experimental studies, seven lenses of between 0 and 30 diopters were visualized. By MRI it was possible to differentiate the various diameters of lenses. It was not possible to discriminate the material of the intraocular lenses. After these first studies the eyes of two corpses and eight patients were investigated. Because of the resolution of MRI it was possible to tell the diopter of implanted lenses. However, by use of MRI in the regular position, a tilting or decentration of the intraocular lens was demonstrated. (orig.)

  12. Electrochemical lysis at the stage of endoresection for large posterior intraocular tumors

    Directory of Open Access Journals (Sweden)

    Yu. A. Belyy

    2012-01-01

    Full Text Available Purpose: to design the new combined technique of endoresection with intraoperative intraocular electrochemical lysis at the tumor destruction stage for large posterior intraocular tumors.Methods: 3 patients (3 eyes with large choroidal melanomas t3N0M0 (tumor thickness — 8-10 mm, base diameter — 13-15 mm, juxtapapillary localization. Mean age was 55.4 years old. Endoresection with intraoperational intraocular electrochemical lysis of the tumor was performed. Electrochemical lysis was performed with use of the technical unit ECU 300 (Soering, Germany and the original method of combined intratumoral positioning of two platinum electrodes: anode and cathode.Results: the tumor was removal completely in all 3 cases. the anatomical retinal reattachment was reached in all patients. Sclera was safe in all 3 cases. Visual acuity was not changed (NLP. At the place of the removal tumor a surgical choroidal coloboma without pigmentation all over scleral bed and periphery was shown in all cases in distant postoperative period (from 1.5 to 3 years. No local recurrences or metastasis were revealed in all patients.Conclusion: Further investigations in clinical group are necessarily to determinate the real possibilities of the combined method and the indications for endoresection with intraoperative intraocular electrochemical lysis for large intraocular tumors. 

  13. Phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism.

    Science.gov (United States)

    Dávila, Pedro J; Ulloa-Padilla, Jan P; Izquierdo, Natalio J

    2017-01-01

    To evaluate the benefits of phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism (OCA). The charts of 195 patients with OCA who visited a local eye clinic were reviewed. All of these patients had genetic linkage analysis to establish OCA type. Frequencies and Paired t-test analysis were determined. Of the 195 patients, nine (4.6%) underwent clear cornea phacoemulsification with intraocular lens implantation. Seven of the nine patients with OCA had the Hermansky-Pudlak (HPS) type 1; two had OCA type 1. Pre-operative BCVA of all eyes ranged from 1.0 to 2.3 logMAR with a mean of 1.42 logMAR and a standard deviation of 0.41 logMAR. Post-operative BCVA of all eyes ranged from 1.0 to 1.30 logMAR with a mean of 1.04 logMAR and a standard deviation of 0.10 logMAR. BCVA improved after phacoemulsification surgery and intraocular lens implantation (p = 0.002). Pre-operative astigmatism of all eyes ranged from +0.50 to +5.75 with a mean of +2.25 and a standard deviation of +2.40. Post-operative astigmatism of all eyes ranged from +0.50 to +2.00 with a mean of +1.23 and a standard deviation of +0.42. Astigmatism improved after phacoemulsification surgery and intraocular lens implantation (p = 0.05). Nine patients with OCA who underwent phacoemulsification and intraocular lens implant experienced improved visual acuity and reduced astigmatism post-operatively. These results suggest cataract surgery may improve vision and refractive errors, and thus quality of life, in patients with albinism.

  14. X-ray diffraction enhanced imaging study of intraocular tumors in human beings

    International Nuclear Information System (INIS)

    Tan Gao; Wang Huaqiao; Chen Yu; Yuan Qing; Li Gang; Zhu Peiping; Zhang Xiaodan; Zhong Xiufeng; Tang Jintian

    2010-01-01

    Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of human eyeball in this work. The images of surgical specimens from malignant intraocular tumor of hospitalized patients were taken using the hard X-rays from the topography station of Beamline 4W1A at Beijing Synchrotron Radiation Facility (BSRF). The obtained radiographic images were analyzed in correlation with those of pathology. The results show that the anatomic and pathologic details of intraocular tumors in human beings can be observed clearly by DEI for the first time, with good visualization of the microscopic details of eyeball ring such as sclera, choroid and other details of intraocular organelles. And the best resolution of DEI images reaches up to the magnitude of several tens of μm. The results suggest that it is capable of exhibiting clearly the details of intraocular tumor using DEI method. (authors)

  15. [Changes in intraocular pressure depending on posture].

    Science.gov (United States)

    Barac, Ramona; Pop, Monica; Tătaru, C; Gheorghe, A; Bădescu, Silvia; Stanciu, Maria; Burcea, M

    2014-01-01

    Glaucoma is an important eye disease that, left untreated, causes irreversible blindness by affecting optic nerve threads. Decreasing intraocular pressure and maintaining it at a low level throughout the day is one of the objectives of antiglaucoma therapy. This is a prospective study conducted on a sample of 80 patients who presented at "Emergency Eye Hospital" Bucharest between 1st of December 2013 30th of July 2014. Patients were divided into two groups: 40 patients with glaucoma and 40 patients without glaucoma (control group). THE OBJECTIVE OF THE STUDY: To determine changes in intraocular pressure that may occur depending on body posture and the correlations between changes in intraocular pressure and glaucoma, obesity, hypertension. These IOP changes may be important in the progression of glaucoma regarding that one third of our time is spent on supine position during night. RESULTS AND CONCLUZIONS: IOP varies from sitting down to supine position. IOP increases in supine in most patients (with or without glaucoma) with an average of 1.25 mmHg. The increase among patients with glaucoma is higher (1.67 mmHg) compared to those without glaucoma (0.82 mmHg). In patients with hypertension and glaucoma, IOP increased with 2.62 mmHg. In patients with hypertension and obesity IOP increased with 2.5 mmHg.

  16. Near-infrared transillumination photography of intraocular tumours.

    Science.gov (United States)

    Krohn, Jørgen; Ulltang, Erlend; Kjersem, Bård

    2013-10-01

    To present a technique for near-infrared transillumination imaging of intraocular tumours based on the modifications of a conventional digital slit lamp camera system. The Haag-Streit Photo-Slit Lamp BX 900 (Haag-Streit AG) was used for transillumination photography by gently pressing the tip of the background illumination cable against the surface of the patient's eye. Thus the light from the flash unit was transmitted into the eye, leading to improved illumination and image resolution. The modification for near-infrared photography was done by replacing the original camera with a Canon EOS 30D (Canon Inc) converted by Advanced Camera Services Ltd. In this camera, the infrared blocking filter was exchanged for a 720 nm long-pass filter, so that the near-infrared part of the spectrum was recorded by the sensor. The technique was applied in eight patients: three with anterior choroidal melanoma, three with ciliary body melanoma and two with ocular pigment alterations. The good diagnostic quality of the photographs made it possible to evaluate the exact location and extent of the lesions in relation to pigmented intraocular landmarks such as the ora serrata and ciliary body. The photographic procedure did not lead to any complications. We recommend near-infrared transillumination photography as a supplementary diagnostic tool for the evaluation and documentation of anteriorly located intraocular tumours.

  17. Intraocular pressure measurement: Goldmann Applanation Tonometer vs non contact airpuff tonometer.

    Science.gov (United States)

    Shah, Masood Alam; Bin Saleem, Khalid; Mehmood, Talat

    2012-01-01

    An accurate assessment of Intraocular pressure (IOP) is vital in establishing diagnosis of Glaucoma and decision making regarding various treatment modalities available. The purpose of this study is to compare Goldmann Applanation Tonometer (GAT) with Air puff tonometer. Cross-sectional comparative study conducted. 73 eyes from 73 patients were included in this study and intraocular pressure (IOP) was measured by GAT and PT100 at Sheikh Khalifa Bin Zayed Hospital, Muzaffarabad, Benazir Shaheed Teaching Hospital, Abbottabad. Mean age of the patients was 53.17 +/- 13.80 years. Mean IOP measurements showed significant differences in measurements performed by the two tonometers (p contact air-puff tonometer, the Goldmann applanation tonometer is a reliable and consistent technique for measurement of intraocular pressure.

  18. Ocular onchocerciasis in the Yanomami communities from Brazilian Amazon: effects on intraocular pressure.

    Science.gov (United States)

    Herzog-Neto, Guilherme; Jaegger, Karen; Nascimento, Erika S do; Marchon-Silva, Verônica; Banic, Dalma M; Maia-Herzog, Marilza

    2014-01-01

    To determine the influence of onchocercal eye disease on the intraocular pressure of the Yanomami Tribe Aratha-ú of Roraima State, Brazil, considered endemic for onchocerciasis, a total of 86 patients were submitted to an ophthalmologic exam that included external examination, slit lamp examination, intraocular pressure measurement, and a fundus ophthalmoscope examination. A high prevalence of onchocerciasis-related eye lesions was encountered in 68.6% of the patients. Punctate keratitis and microfilariae in the anterior chamber were found in ∼28%. The mean of intraocular eye pressure found was 10.47 mm of Hg.

  19. Sensitivity of the corneal-plane refractive compensation to change in power and axial position of an intraocular lens

    Directory of Open Access Journals (Sweden)

    W. F. Harris

    2009-12-01

    Full Text Available If an intraocular lens is displaced or if its power is changed what are the consequences for the refractive compensation of the eye?  Gaussian optics is used to obtain explicit formulae for the sensitivityof the corneal-plane refractive compensation (also called the refraction, refractive state, etc to change in power and axial displacement of a thin intraocular lens implanted in a simple eye.  In particular, for a pseudophakic Gullstrand simplified eye with intraocular lens placed 5 mm behind the cornea the sensitivity to errors in the power of the intraocular lens is about  71 . 0 − 71 for an intraocular lens of power   for an intraocular lens of power 20 D, that is, the refractive compensation decreases by about 0.71 dioptres per dioptre increase in the power of the intraocular lens.  More generally the sensitivity is approximately  ( m   0037 . 0 63 . 0 F − − 0.63 ( 003 . 0 63 . 0 − − (0.0037mF where FI is the power of the intraocular lens.  Also for Gullstrand’s simplified eye the sensitivity of refractive compensation to axial displacement of the intraocular lens is approximately linear in FI about  (64D FI, in fact.  That is, for each dioptre of the power of the intraocular lens the refractive compensation increases by about 0.064 dioptres per millimetre of axial displacement towards the retina. 

  20. Intraocular Pressure Increases After Intraarticular Knee Injection With Triamcinolone but Not Hyaluronic Acid.

    Science.gov (United States)

    Taliaferro, Kevin; Crawford, Alexander; Jabara, Justin; Lynch, Jonathan; Jung, Edward; Zvirbulis, Raimonds; Banka, Trevor

    2018-03-09

    Intraarticular steroid injections are a common first-line therapy for severe osteoarthritis, which affects an estimated 27 million people in the United States. Although topical, oral, intranasal, and inhalational steroids are known to increase intraocular pressure in some patients, the effect of intraarticular steroid injections on intraocular pressure has not been investigated, to the best of our knowledge. If elevated intraocular pressure is sustained for long periods of time or is of sufficient magnitude acutely, permanent loss of the visual field can occur. How does intraocular pressure change 1 week after an intraarticular knee injection either with triamcinolone acetonide or hyaluronic acid? A nonrandomized, nonblinded prospective cohort study was conducted at an outpatient, ambulatory orthopaedic clinic. This study compared intraocular pressure elevation before and 1 week after intraarticular knee injection of triamcinolone acetonide versus hyaluronic acid for management of primary osteoarthritis of the knee. Patients self-selected to be injected in their knee with either triamcinolone acetonide or hyaluronic acid before being informed of the study. The primary endpoint was intraocular pressure elevation of ≥ 7 mm Hg 1 week after injection. This cutoff is determined as the minimum significant pressure change in the ophthalmology literature recognized as an intermediate responder to steroids. Intraocular pressure was measured using a handheld Tono-Pen® applanation device. This device is frequently used in intraocular pressure measurement in clinical and research settings; 10 sequential measurements are obtained and averaged with a confidence interval. Only measurements with a 95% confidence interval were used. Over a 6-month period, a total of 96 patients were approached to enroll in the study. Sixty-two patients out of 96 approached (65%) agreed. Thirty-one (50%) were injected with triamcinolone and 31 (50%) were injected with hyaluronic acid. Patients

  1. Intraocular gnathostomiasis: report of a case and review of literature.

    Science.gov (United States)

    Pillai, Gopal S; Kumar, Anil; Radhakrishnan, Natasha; Maniyelil, Jayasree; Shafi, Tufela; Dinesh, Kavitha R; Karim, Shamsul

    2012-04-01

    Intraocular gnathostomiasis is a rare parasitic infection caused by the third-stage larvae of spiruroid nematode Gnanthostoma spp. seen mostly in tropical and subtropical regions. It is a food-borne zoonosis caused by ingestion of raw or undercooked freshwater fish, amphibians, reptiles, birds, and mammals, all of which are known to harbor advanced third-stage larvae of Gnanthostoma spp. To date, 74 cases of intraocular gnathostomiasis have been reported from 12 different countries. Only four countries have reported more than 10 cases each, and India shares the rare distinction of being one of them, with 14 cases. Surprisingly, not a single case of cutaneous gnanthostomiasis has ever been reported from India. We present one such case of intraocular gnathostomiasis in a 41-year-old male who presented with an actively motile worm attached to the iris, and we review the pertinent literature of all such cases reported from India.

  2. Sutureless Intrascleral Fixated Intraocular Lens Implantation.

    Science.gov (United States)

    Karadag, Remzi; Celik, Haci Ugur; Bayramlar, Huseyin; Rapuano, Christopher J

    2016-08-01

    To review sutureless intrascleral intraocular lens (IOL) fixation methods. Review of published literature. Sutureless intrascleral IOL fixation methods are newer and have been developed to eliminate the suture-related complications of sutured scleral fixation methods such as suture-induced inflammation or infection and IOL dislocation or subluxation due to suture degradation or suture breakage. Sutureless intrascleral fixation methods aim for intrascleral haptic fixation to achieve stability of the IOL. Various methods of sutureless scleral fixation have been described. Using a needle, a blade, or a trochar, sclerostomies are created in all techniques for intraocular access. Some surgeons prefer to create scleral tunnels, whereas others use scleral flaps for scleral fixation of haptics. The stability of IOLs is attained by the scar tissue formed around the haptics. Short-term results of these new methods are acceptable; studies including more cases with longer follow-up are needed to determine their long-term success. [J Cataract Refract Surg. 2016;32(9):586-597.]. Copyright 2016, SLACK Incorporated.

  3. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Simon, V., E-mail: viosimon@phys.ubbcluj.ro [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Radu, T.; Vulpoi, A. [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Rosca, C. [Optilens Clinic of Ophthalmology, 400604 Cluj-Napoca (Romania); Eniu, D. [Iuliu Haţieganu University of Medicine and Pharmacy, Department of Molecular Sciences, 400349 Cluj-Napoca (Romania)

    2015-01-15

    Highlights: • Changes on intraocular lens (IOL) surface after implantation. • Partial opacification of IOL central area. • Elemental composition on IOL surface prior to and after implantation. • First XPS depth profiling examination of the opacifying deposits. • Cell-mediated hydroxyapatite structuring. - Abstract: The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  4. Intravitreal triamcinolone for intraocular inflammation and associated macular edema

    Directory of Open Access Journals (Sweden)

    Steven M Couch

    2008-11-01

    Full Text Available Steven M Couch, Sophie J BakriMayo Clinic Department of Ophthalmology, Mayo Clinic, Rochester, MN, USAAbstract: Triamcinolone acetonide (TA is a corticosteroid that has many uses in the treatment of ocular diseases because of its potent anti-inflammatory and anti-permeability actions. Intraocular inflammation broadly referred to as uveitis can result from several causes, including the immune system and after ophthalmic surgery. One of the most common reasons for vision loss with uveitis is macular edema. TA has been used for many years as an intravitreal injection for the treatment of ocular diseases. Several case control studies have been reported showing the efficacy of TA in the treatment of intraocular inflammation and associated macular edema caused by Behcet’s disease, Vogt-Koyanagi-Harada syndrome, sympathetic ophthalmia and white dot syndromes. It has also been shown efficacious in cases of pars planitis and idiopathic posterior uveitis. Some authors have reported its use in postoperative cystoid macular edema. Many of the studies on the use of TA in controlling intraocular inflammation and concomitant macular edema showed its effect to be transient in many patients requiring reinjection. Complications can arise from intravitreal injection of TA including elevated intraocular pressure and cataract. Rarely, it can be associated with infectious and non-infectious endophthalmitis. TA may be useful as an adjuvant in the treatment of uveitis and its associated macular edema, especially in patients resistant or intolerant to standard treatment.Keywords: triamcinolone acetonide, Behcet’s disease, sympathetic ophthalmia, Vogt-Koyanagi-Harada syndrome, white dot syndromes, uveitis, cataract surgery, macular edema, endophthalmitis

  5. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  6. Outcomes and Complications of Scleral-Fixated Intraocular Lens Combined with Ahmed Tube Surgery

    Directory of Open Access Journals (Sweden)

    Nikhel Sachdev

    2018-01-01

    Full Text Available Background. To evaluate the outcome and complications of transscleral suture-fixated posterior chamber intraocular lens (PCIOL implantation combined with Ahmed glaucoma valve (AGV surgery in Asian eyes. Design. This was a retrospective study that included 22 eyes from 22 participants. The surgeries were performed at Singapore’s National University Hospital. Participants underwent an Ahmed tube surgery, together with transscleral suture-fixated posterior chamber intraocular lens. Main Outcome Measures. Complete success was defined as 6 ≤ intraocular pressure (IOP ≤ 21 mmHg without medications at the last follow-up visit, with no reoperation required and no progression to no perception of light (NPL. Results. At the last follow-up, there was a significant reduction in mean IOP (22.4 ± 6.5 mmHg versus 13.9 ± 3.9 mmHg; p<0.001 and mean number of intraocular pressure-lowering medications (2.45 ± 1.30 versus 0.05 ± 0.21; p<0.001. There was no significant change in visual acuity [1.43 ± 1.21 (LogMAR versus 1.09 ± 1.31 (p=0.204]. Sixteen eyes (72.7% achieved complete success. The 3 commonest complications were bullous keratopathy, choroidal detachment, and displacement of intraocular lens. Conclusion and Relevance. This technique showed good success for intraocular pressure control and vision preservation. Postoperative complications were relatively common although most were self-limiting. Patients at increased risk of trabeculectomy failure may be suitable for this procedure.

  7. Intraocular foreign-body hazard during vitrectomy.

    Science.gov (United States)

    Bovino, J A; Marcus, D F

    1982-03-01

    We noted two instances of forceps-induced fragmentation of the bar used for scleral plug storage during vitreous surgery. The silicone bar material was adherent to the plug in both cases. Because this represents a significant intraocular foreign body hazard, the scleral plug should be carefully inspected before insertion.

  8. Bilateral Acute Angle-closure after Intraocular Surgery.

    Science.gov (United States)

    Hoskens, Kirsten; Pinto, Luis Abegão; Vandewalle, Evelien; Verdonk, Nancy; Stalmans, Ingeborg

    2014-01-01

    We report the case of a 75-year-old woman who developed an acute bilateral angle-closure associated with choroidal effusion a day after an uneventful cataract surgery. The same patient had undergone a similarly uneventful cataract surgery two weeks before, under the same protocol, with no postoperative complication in the other eye. Medical treatment, including the use of oral sulfamide-related drugs (acetazolamide), topical beta-blockers and steroids led to a gradual decrease in intraocular pressure (IOP) and choroidal effusion. Despite initial reports suggesting a link between sulfamide-exposure and these rare forms of angle-closure, our report would suggest a more complex pathophysiology behind this intriguing phenomenon. How to cite this article: Hoskens K, Pinto LA, Vandewalle E, Verdonk N, Stalmans I. Bilateral Acute Angle-closure after Intraocular Surgery. J Curr Glaucoma Pract 2014;8(3):113-114.

  9. Changes of intraocular pressure in different trimesters of pregnancy among Syrian refugees in Turkey: A cross-sectional study.

    Science.gov (United States)

    Tolunay, Harun Egemen; Özcan, Sait Coşkun; Şükür, Yavuz Emre; Özarslan Özcan, Deniz; Adıbelli, Fatih Mehmet; Hilali, Neşe Gül

    2016-06-01

    To evaluate the physiologic changes in intraocular pressure associated with pregnancy in healthy Syrian refugee women in Turkey. In this cross-sectional study, intraocular pressures were measured using a Goldmann tonometer in 235 patients in the first, second, and third trimester of pregnancy and puerperium among Syrian refugees in Turkey. Mean intraocular pressures values of the right eye were 15.5±2.5 mmHg, 14.4±1.4 mmHg, 13.9±1.6 and 14.7±1.9 mmHg in the three trimesters and puerperium, respectively. Mean intraocular pressures values of the left eye were 15.3±1.6 mmHg, 14.3±1.4 mmHg, 13.9±1.6 and 15.3±2.2 mmHg in the three trimesters and puerperium, respectively. The mean intraocular pressures values measured from both eyes were significantly higher in first trimester and puerperal period than in the third trimester (p<0.001). Changes in the intraocular pressure in pregnancy are common and temporary. This study shows the baseline changes in the intraocular pressure during pregnancy in healthy women. Therefore, we cannot extrapolate the results to the whole eye. A decrease in intraocular pressures was shown in healthy pregnant women.

  10. INTRAOCULAR TRANSMISSIBLE VENEREAL TUMOR IN A DOG TUMOR VENÉREO TRANSMISSÍVEL INTRA-OCULAR EM CÃO

    Directory of Open Access Journals (Sweden)

    Geórgia Nadalini Rodrigues

    2001-02-01

    Full Text Available Canine transmissible venereal tumor (TVT is a round cell neoplasm occurring on the external genital mucosa of male and female dogs. Transmission is by cell implantation during coitus, licking, or other interaction between an affected dog and a susceptible host. Metastasis of the tumor rarely occurs. This report describes an unusual presentation of TVT with intraocular involvement and inguinal lymph nodes metastasis. The subject was a six-year-old, intact, male, Brazilian Terrier dog with a history of abnormal masses in the right eye, penis and several subcutaneous nodules in the inguinal area. Histopathological examination of the eye specimens as well as cytologic examination of penile mass and subcutaneous nodules revealed similar findings. The examination revealed round cells containing a large nuclei with prominent, central located nucleoli and a pale cytoplasm containing few small, clear round vacuoles. Histologically, the subcutaneous nodules in the inguinal area were lymph nodes. The diagnosis of TVT with intraocular involvement and lymph nodes metastasis was based on clinical, cytologic and histopathologic findings.Tumor venéreo transmissível (TVT é uma neoplasia de células redondas que acomete a mucosa genital externa de cães, machos e fêmeas. A transmissão decorre da implantação de células tumorais durante o coito, brigas ou interações entre animais portadores e susceptíveis. Existem relatos referindo-se a localizações atípicas do TVT, mas metástases raramente ocorrem. O presente relato descreve um caso incomum de TVT, com acometimento intra-ocular e metástases nos linfonodos ingüinais, num cão Terrier Brasileiro, com seis anos de idade. O animal apresentava massas anormais de tecido no olho direito, extremidade do pênis e aumento de volume de linfonodos da região ingüinal. A histopatologia do globo ocular e as citologias da massa peniana e dos nódulos subcutâneos evidenciaram aspectos citológicos semelhantes

  11. [Hormonal homeostasis and intraocular pressure in chronic emotional stress caused by influences acting on the amygdala].

    Science.gov (United States)

    Isakova, L S; Danilov, G E; Egorkina, S B; Butolin, E G

    1989-01-01

    Changes in intraocular pressure, eye hydrodynamics and the amount of hypophyseal, thyroid, adrenal and pancreatic hormones were studied during continuous stimulation of amygdaloid complex or after administration of angiotensin II into the structure in rabbits. The effects involved changes in hormonal homeostasis and elevation of intraocular pressure due to a hypersecretion of intraocular fluid. The administration of angiotensin II during the amygdala stimulation enhanced the changes.

  12. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  13. MRI and intraocular tamponade media

    Energy Technology Data Exchange (ETDEWEB)

    Manfre, I. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy)); Fabbri, G. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy)); Avitabile, T. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Biondi, P. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Reibaldi, A. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Pero, G. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy))

    1993-05-01

    Thirteen patients who underwent surgery for retinal detachment and injection of intraocular tamponade media (silicone oil, flurosilicone oil, or perfluoro-carbon liquid) underwent magnetic resonance imaging (MRI), using spin-echo T1- and T2-weighted images. The ophthalmic tamponade media showed different signal intensity, according to their chemical structure. Unlike ophthalmoscopy or ultrasonography, MRI showed no oil-related artefact, making possible recognition of recurrent retinal detachment. (orig.)

  14. MRI and intraocular tamponade media

    International Nuclear Information System (INIS)

    Manfre, I.; Fabbri, G.; Avitabile, T.; Biondi, P.; Reibaldi, A.; Pero, G.

    1993-01-01

    Thirteen patients who underwent surgery for retinal detachment and injection of intraocular tamponade media (silicone oil, flurosilicone oil, or perfluoro-carbon liquid) underwent magnetic resonance imaging (MRI), using spin-echo T1- and T2-weighted images. The ophthalmic tamponade media showed different signal intensity, according to their chemical structure. Unlike ophthalmoscopy or ultrasonography, MRI showed no oil-related artefact, making possible recognition of recurrent retinal detachment. (orig.)

  15. Exact results for N=2 supersymmetric gauge theories on compact toric manifolds and equivariant Donaldson invariants

    International Nuclear Information System (INIS)

    Bershtein, Mikhail; Bonelli, Giulio; Ronzani, Massimiliano; Tanzini, Alessandro

    2016-01-01

    We provide a contour integral formula for the exact partition function of N=2 supersymmetric U(N) gauge theories on compact toric four-manifolds by means of supersymmetric localisation. We perform the explicit evaluation of the contour integral for U(2) N=2"∗ theory on ℙ"2 for all instanton numbers. In the zero mass case, corresponding to the N=4 supersymmetric gauge theory, we obtain the generating function of the Euler characteristics of instanton moduli spaces in terms of mock-modular forms. In the decoupling limit of infinite mass we find that the generating function of local and surface observables computes equivariant Donaldson invariants, thus proving in this case a long-standing conjecture by N. Nekrasov. In the case of vanishing first Chern class the resulting equivariant Donaldson polynomials are new.

  16. Central Corneal Thickness And Its Relationship To Intra-ocular And Epidemiological Determinants

    International Nuclear Information System (INIS)

    Tayyab, A.; Masrur, A.

    2016-01-01

    Objective: To measure central corneal thickness in Pakistani population and determine its relationship to intra-ocular pressure, age, gender and ethnicity. Study Design: Cross-sectional observation study. Place and Duration of Study: Pakistan Institute of Medical Sciences, Islamabad, Pakistan, between December 2013 and February 2015. Methodology: The right eyes of 1000 cases (496 males and 504 females) were recruited for this study. Inclusion criteria were Pashtun or Punjabi ethnicity, intra-ocular pressure < 22 mmHg, gonioscopically open angles, cup-disk-ratio < 0.5, and age matched normal visual fields. Cases with prior ocular surgery, contact lens use, corneal pathologies, myopia or hypermetropia > ±3.0 diopters, astigmatism of > ±1.0 diopters were excluded. Central corneal thickness was measured using a TopCon non-contact specular microscope. Intra-ocular pressure was measured using Goldmann applanation tonometer. Frequency distribution, test of significance, and regression analysis was carried out using Statistical Package for Social Sciences version 20.0. Result: Mean age was 47.31 ±11.78 years. Ethnic composition was 51.6 percentage (n=516) Pashtun and 48.4 percentage (n=484) Punjabi. The mean central corneal thickness was 503.96 (±12.47) meu m, while the mean intra-ocular pressure was 15.61 (±2.68) mmHg. Regression analysis showed a significant association between central corneal thickness and intra-ocular pressure (p=0.00) and age (p=0.00). A ±100 μ change in central corneal thickness was associated with change in IOP of ±3.30 mmHg, whereas central corneal thickness decreased by 0.12 meu m per year. No significant association could be established between central corneal thickness and ethnicity (p=0.19). Conclusion: Central corneal thickness of the studied races was comparable to non-Caucasians which affects intra-ocular pressure measurements, and decreases with increasing age. No relationship was observed between central corneal thickness and

  17. Comparison of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients

    Directory of Open Access Journals (Sweden)

    Zhan-Jiang Liu

    2016-01-01

    Full Text Available AIM:To investigate the effects of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients. METHODS:Seventy-seven patients(128 eyeswere treated by phacoemulsification combined with intraocular lens implantation from January 2014 to March 2015 in our hospital. Thirty-nine patients(65 eyeswere treated with Bigbag intraocular lens, 38 cases(63 eyeswere treated with Rayner620H. The best corrected visual acuity(BCVAdistribution, the actual refractive value, the difference between predictive refractive value and actual refractive value and complications were measured and recorded in the two groups at 1mo after surgeries. RESULTS:The difference between the two groups on BCVA are statistically significant(PWilcoxon rank sum test. The differences between predictive refractive value and actual refractive value of the two groups were statistically significant(PPCONCLUSION:The effect of Bigbag intraocular lens for patients with phacoemulsification and intraocular lens implantation is good, and it can reduce the risk of complications.

  18. Evaluating the risk of eye injuries: intraocular pressure during high speed projectile impacts.

    Science.gov (United States)

    Duma, Stefan M; Bisplinghoff, Jill A; Senge, Danielle M; McNally, Craig; Alphonse, Vanessa D

    2012-01-01

    To evaluate the risk of eye injuries by determining intraocular pressure during high speed projectile impacts. A pneumatic cannon was used to impact eyes with a variety of projectiles at multiple velocities. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve. A total of 36 tests were performed on 12 porcine eyes with a range of velocities between 6.2 m/s and 66.5 m/s. Projectiles selected for the test series included a 6.35  mm diameter metal ball, a 9.25  mm diameter aluminum rod, and an 11.16  mm diameter aluminum rod. Experiments were designed with velocities in the range of projectile consumer products such as toy guns. A range of intraocular pressures ranged between 2017 mmHg to 26,426 mmHg (39 psi-511 psi). Four of the 36 impacts resulted in globe rupture. Intraocular pressures dramatically above normal physiological pressure were observed for high speed projectile impacts. These pressure data provide critical insight to chronic ocular injuries and long-term complications such as glaucoma and cataracts.

  19. Stability of Adrenaline in Irrigating Solution for Intraocular Surgery.

    Science.gov (United States)

    Shibata, Yuuka; Kimura, Yasuhiro; Taogoshi, Takanori; Matsuo, Hiroaki; Kihira, Kenji

    2016-01-01

    Intraocular irrigating solution containing 1 µg/mL adrenaline is widely used during cataract surgery to maintain pupil dilation. Prepared intraocular irrigating solutions are recommended for use within 6 h. After the irrigating solution is admistered for dilution, the adrenaline may become oxidized, and this may result in a decrease in its biological activity. However, the stability of adrenaline in intraocular irrigating solution is not fully understood. The aim of this study was to evaluate the stability of adrenaline in clinically used irrigating solutions of varying pH. Six hours after mixing, the adrenaline percentages remaining were 90.6%±3.7 (pH 7.2), 91.1%±2.2 (pH 7.5), and 65.2%±2.8 (pH 8.0) of the initial concentration. One hour after mixing, the percentages remaining were 97.6%±2.0 (pH 7.2), 97.4%±2.7 (pH 7.5), and 95.6%±3.3 (pH 8.0). The degradation was especially remarkable and time dependent in the solution at pH 8.0. These results indicate that the concentration of adrenaline is decreased after preparation. Moreover, we investigated the influence of sodium bisulfite on adrenaline stability in irrigating solution. The percentage adrenaline remaining at 6 h after mixing in irrigating solution (pH 8.0) containing sodium bisulfite at 0.5 µg/mL (concentration in irrigating solution) or at 500 µg/mL (concentration in the undiluted adrenaline preparation) were 57.5 and 97.3%, respectively. Therefore, the low concentration of sodium bisulfite in the irrigating solution may be a cause of the adrenaline loss. In conclusion, intraocular irrigation solution with adrenaline should be prepared just prior to its use in surgery.

  20. Experimental research on intraocular aqueous flow by PIV method.

    Science.gov (United States)

    Yang, Hongyu; Song, Hongfang; Mei, Xi; Li, Lin; Fu, Xineng; Zhang, Mindi; Liu, Zhicheng

    2013-10-21

    Aqueous humor flows regularly from posterior chamber to anterior chamber, and this flow much involves intraocular pressure, the eye tissue nutrition and metabolism. To visualize and measure the intraocular flow regular pattern of aqueous humor. Intraocular flow in the vitro eyeball is driven to simulate the physiological aqueous humor flow, and the flow field is measured by Particle Image Velocimetry(PIV). Fluorescent particle solution of a certain concentration was infused into the root of Posterior Chamber(PC) of vitro rabbit eye to simulate the generation of aqueous and was drained out at a certain hydrostatic pressure from the angle of Anterior Chamber(AC) to represent the drainage of aqueous. PIV method was used to record and calculate the flow on the midsagittal plane of the eyeball. Velocity vector distribution in AC has been obtained, and the distribution shows symmetry feature to some extent. Fluorescent particle solution first fills the PC as it is continuously infused, then surges into AC through the pupil, flows upwards toward the central cornea, reflecting and scattering, and eventually converges along the inner cornea surface towards the outflow points at the periphery of the eyeball. Velocity values around the pupillary margin are within the range of 0.008-0.012 m/s, which are close to theoretical values of 0.0133 m/s, under the driving rate of 100 μl/min. Flow field of aqueous humor can be measured by PIV method, which makes it possible to study the aqueous humor dynamics by experimental method. Our study provides a basis for experimental research on aqueous humor flow; further, it possibly helps to diagnose and treat eye diseases as shear force damage of ocular tissues and destructions on corneal endothelial cells from the point of intraocular flow field.

  1. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-08-01

    Full Text Available Mun Yueh Faria,1–3 Nuno Pinto Ferreira,1–3 Joana Medeiros Pinto,1–3 David Cordeiro Sousa,1–3 Ines Leal,1–3 Eliana Neto,1–3 Carlos Marques-Neves1–3 1Centro de Estudos da Visão, Universidade de Lisboa, 2Department of Ophthalmology, Hospital de Santa Maria, 3Faculty of Medicine, University of Lisbon, Lisbon, Portugal Background: Nowadays, dislocated intraocular lenses (IOLs and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL.Methods: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth.Results: The mean follow-up was 23 months (range: 6–48 months. The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1 retinal detachment was found in one patient, 2 corneal edema was found in three patients, 3 high intraocular pressure was observed in

  2. Intraocular robotic interventional surgical system (IRISS): Mechanical design, evaluation, and master-slave manipulation.

    Science.gov (United States)

    Wilson, Jason T; Gerber, Matthew J; Prince, Stephen W; Chen, Cheng-Wei; Schwartz, Steven D; Hubschman, Jean-Pierre; Tsao, Tsu-Chin

    2018-02-01

    Since the advent of robotic-assisted surgery, the value of using robotic systems to assist in surgical procedures has been repeatedly demonstrated. However, existing technologies are unable to perform complete, multi-step procedures from start to finish. Many intraocular surgical steps continue to be manually performed. An intraocular robotic interventional surgical system (IRISS) capable of performing various intraocular surgical procedures was designed, fabricated, and evaluated. Methods were developed to evaluate the performance of the remote centers of motion (RCMs) using a stereo-camera setup and to assess the accuracy and precision of positioning the tool tip using an optical coherence tomography (OCT) system. The IRISS can simultaneously manipulate multiple surgical instruments, change between mounted tools using an onboard tool-change mechanism, and visualize the otherwise invisible RCMs to facilitate alignment of the RCM to the surgical incision. The accuracy of positioning the tool tip was measured to be 0.205±0.003 mm. The IRISS was evaluated by trained surgeons in a remote surgical theatre using post-mortem pig eyes and shown to be effective in completing many key steps in a variety of intraocular surgical procedures as well as being capable of performing an entire cataract extraction from start to finish. The IRISS represents a necessary step towards fully automated intraocular surgery and demonstrated accurate and precise master-slave manipulation for cataract removal and-through visual feedback-retinal vein cannulation. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Effects of phacoemulsification combined with intraocular lens implantation on ocular surface

    Directory of Open Access Journals (Sweden)

    Ming Li

    2013-10-01

    Full Text Available AIM: To explore the changes of ocular surface after phacoemulsification combined with intraocular lens implantation. METHODS: Totally 78 cases of 78 eyes with age-related cataract were collected from August 2011 to October 2012, and they underwent corneal incision phacoemulsification combined with intraocular lens implantation. The score of dry eye symptoms; tear breakup time(BUT; Schirmer Ⅰ test(SⅠtand corneal fluorescein staining were observed and recorded in 3 days before, 1 day, 1 week, 1 month, 3 and 6 months after surgery respectively. The results were analyzed statistically. RESULTS: All the subjects complained of dry eye within 1 week after surgery. Compared with 3 days before the surgery, the corneal fluorescein staining increased and the amount of tear secretion reduced statistically significant in 1 day, 1 week and 1 month(PPP>0.05, and lasted to 3 months later. CONCLUSION: Phacoemulsification combined with intraocular lens implantation has obvious effect on the ocular surface to some extent. Preventions and treatment should be taken clinically.

  4. The Visual Effects of Intraocular Colored Filters

    Directory of Open Access Journals (Sweden)

    Billy R. Hammond

    2012-01-01

    Full Text Available Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans.

  5. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery

    Science.gov (United States)

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-01-01

    Abstract Background: Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Methods: Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Results: Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16–0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: −1.32, 95% CI = −2.39 to −0.25, P = .015) and estimated PCO score (diff. in means: −2.23; 95% CI, −3.80 to −0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: −0.075; 95% CI, −0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: −0.016; 95% CI, −0.041 to 0.009, P = .208). Conclusion: In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity. PMID:29095259

  6. Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia.

    Science.gov (United States)

    Hamed-Azzam, Shirin; Briscoe, Daniel; Tomkins, Oren; Shehedeh-Mashor, Raneen; Garzozi, Hanna

    2013-08-01

    Intraocular pressure is affected by corneal thickness and biomechanics. Following ablative corneal refractive surgery, corneal structural changes occur. The purpose of the study is to determine the relationship between the mean central corneal thickness (CCT) and the change in intraocular pressure measurements following various corneal ablation techniques, using different measurement methods. Two hundred myopic eyes undergoing laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) were enrolled into a prospective, non-randomized study. Corneal parameters examined included full ocular examination, measurement of CCT, corneal topography, corneal curvature and ocular refractivity. Intraocular pressure measurements were obtained using three different instruments-non-contact tonometer, Goldmann applanation tonometer and TonoPen XL (TonoPen-Central and TonoPen-Peripheral). All measurements were performed pre-operatively and 4 months post-operatively. Post-operative intraocular pressure was significantly lower than pre-operative values, with all instruments (p value tonometer and non-contact tonometer (p value < 0.001, ANOVA). Intraocular pressure readings are significantly reduced following corneal ablation surgery. We determined in our myopic patient cohort that the TonoPen XL intraocular pressure measurement method is the least affected following PRK and LASIK as compared to other techniques.

  7. The role of pili in Bacillus cereus intraocular infection.

    Science.gov (United States)

    Callegan, Michelle C; Parkunan, Salai Madhumathi; Randall, C Blake; Coburn, Phillip S; Miller, Frederick C; LaGrow, Austin L; Astley, Roger A; Land, Craig; Oh, So-Young; Schneewind, Olaf

    2017-06-01

    Bacterial endophthalmitis is a potentially blinding intraocular infection. The bacterium Bacillus cereus causes a devastating form of this disease which progresses rapidly, resulting in significant inflammation and loss of vision within a few days. The outer surface of B. cereus incites the intraocular inflammatory response, likely through interactions with innate immune receptors such as TLRs. This study analyzed the role of B. cereus pili, adhesion appendages located on the bacterial surface, in experimental endophthalmitis. To test the hypothesis that the presence of pili contributed to intraocular inflammation and virulence, we analyzed the progress of experimental endophthalmitis in mouse eyes infected with wild type B. cereus (ATCC 14579) or its isogenic pilus-deficient mutant (ΔbcpA-srtD-bcpB or ΔPil). One hundred CFU were injected into the mid-vitreous of one eye of each mouse. Infections were analyzed by quantifying intraocular bacilli and retinal function loss, and by histology from 0 to 12 h postinfection. In vitro growth and hemolytic phenotypes of the infecting strains were also compared. There was no difference in hemolytic activity (1:8 titer), motility, or in vitro growth (p > 0.05, every 2 h, 0-18 h) between wild type B. cereus and the ΔPil mutant. However, infected eyes contained greater numbers of wild type B. cereus than ΔPil during the infection course (p ≤ 0.05, 3-12 h). Eyes infected with wild type B. cereus experienced greater losses in retinal function than eyes infected with the ΔPil mutant, but the differences were not always significant. Eyes infected with ΔPil or wild type B. cereus achieved similar degrees of severe inflammation. The results indicated that the intraocular growth of pilus-deficient B. cereus may have been better controlled, leading to a trend of greater retinal function in eyes infected with the pilus-deficient strain. Although this difference was not enough to significantly alter the severity

  8. Locally Advanced Basal Cell Carcinoma with Intraocular Invasion

    Directory of Open Access Journals (Sweden)

    Georgi Tchernev

    2018-01-01

    Full Text Available We present a 103 - year - old patient, with duration of complaints of about ten years. The initial complaint had been presented as a small nodule, located on the eyebrow, which subsequently ulcerated and encompassed larger regions of the upper and lower eyelids. For the past three years, the patient also had complaints of a worsening of his vision, without seeking for medical help. Within the dermatological examination, an intraocular and periocular localised tumour was established, characterised by a raised peripheral edge and central ulceration. More careful examination revealed that the bulb was fully consumed. The patient refused further diagnosis and treatment. Advanced basal cell carcinomas with intraocular invasion are rare in general. If the patient refuses surgery, radiotherapy and systemic therapy with modern medications such as Vismodegib or Sonidegib are available as treatment options.

  9. Intraocular eyelashes and iris cyst in anterior chamber following penetrating eye injury: a case report

    Directory of Open Access Journals (Sweden)

    Sahu S

    2017-03-01

    Full Text Available Sabin Sahu,1 Lila Raj Puri,1 Sanjay Kumar Singh2 1Department of Ophthalmology, Sagarmatha Choudhary Eye Hospital, Lahan, Siraha, 2Department of Ophthalmology, Biratnagar Eye Hospital, Biratnagar, Nepal Background: The presence of intraocular eyelashes following penetrating eye injury or ocular surgery is relatively uncommon. The response of the eye to intraocular eyelashes is variable. The eyelash may be symptomatic or may remain asymptomatic for long periods. Objective: We report a case with two intraocular eyelashes and an iris cyst after 2 years of asymptomatic period following penetrating eye injury. Case presentation: A 24-year-old male presented with decreased vision in the left eye which he had noticed for the previous 2 weeks. His visual acuity was 6/6 in the right eye and 6/18 in the left eye, improving to 6/9 with -2.5 DC × 140° correction. The intraocular pressure was 12 mmHg in both eyes. On slit-lamp examination, the left eye showed 8 mm linear peripheral corneal opacity nasally, two eyelashes in the superior anterior chamber, and an iris cyst measuring 4 mm × 4 mm in the superior iris. The right eye was normal. Dilated fundus examination of both eyes was normal. The eyelashes and cyst were removed surgically. There were no complications during the 3-month follow-up period. Conclusion: Intraocular implantation of eyelashes following penetrating eye injury can remain asymptomatic for long periods; however, late development of iris cyst may occur. Keywords: intraocular eyelashes, iris cyst, penetrating eye injury

  10. Lentes intraoculares fácicas de câmara posterior

    Directory of Open Access Journals (Sweden)

    Mara Barreto Theiss

    Full Text Available Resumo O objetivo deste artigo foi reunir estudos que reportam resultados disponíveis na literatura científica, considerando a previsibilidade, segurança, eficácia, e estabilidade das lentes intraoculares fácicas de câmara posterior. E relatar as complicações documentadas para estas lentes. A revisão criteriosa dos estudos publicados na literatura ate o momento revelam resultado satisfatórios quanto à eficácia, elevada previsibilidade, estabilidade e segurança do implante de lente intraocular de câmara posterior, para correção das miopia, hipermetropia e astigmatismo.

  11. MicroRNA profiling in intraocular medulloepitheliomas.

    Directory of Open Access Journals (Sweden)

    Deepak P Edward

    Full Text Available To study the differential expression of microRNA (miRNA profiles between intraocular medulloepithelioma (ME and normal control tissue (CT.Total RNA was extracted from formalin fixed paraffin embedded (FFPE intraocular ME (n=7 and from age matched ciliary body controls (n=8. The clinical history and phenotype was recorded. MiRNA profiles were determined using the Affymetrix GeneChip miRNA Arrays analyzed using expression console 1.3 software. Validation of significantly dysregulated miRNA was confirmed by quantitative real-time PCR. The web-based DNA Intelligent Analysis (DIANA-miRPath v2.0 was used to perform enrichment analysis of differentially expressed (DE miRNA gene targets in Kyoto Encyclopedia of Genes and Genomes (KEGG pathway.The pathologic evaluation revealed one benign (benign non-teratoid, n=1 and six malignant tumors (malignant teratoid, n=2; malignant non-teratoid, n = 4. A total of 88 miRNAs were upregulated and 43 miRNAs were downregulated significantly (P<0.05 in the tumor specimens. Many of these significantly dysregulated miRNAs were known to play various roles in carcinogenesis and tumor behavior. RT-PCR validated three significantly upregulated miRNAs and three significantly downregulated miRNAs namely miR-217, miR-216a, miR-216b, miR-146a, miR-509-3p and miR-211. Many DE miRNAs that were significant in ME tumors showed dysregulation in retinoblastoma, glioblastoma, and precursor, normal and reactive human cartilage. Enriched pathway analysis suggested a significant association of upregulated miRNAs with 15 pathways involved in prion disease and several types of cancer. The pathways involving significantly downregulated miRNAs included the toll-like receptor (TLR (p<4.36E-16 and Nuclear Factor kappa B (NF-κB signaling pathways (p<9.00E-06.We report significantly dysregulated miRNAs in intraocular ME tumors, which exhibited abnormal profiles in other cancers as well such as retinoblastoma and glioblastoma. Pathway analysis

  12. Influence of gross saponins from tribulus terrestris L on SOD activity and MDA content for chronic high intraocular pressure in rabbit

    Directory of Open Access Journals (Sweden)

    Nuo Li

    2013-05-01

    Full Text Available AIM:To observe influence of gross saponins from tribulus terrestris L(GSTTon SOD activity and MDA content for chronic high intraocular pressure in rabbit, and discusses the retina oxidative damage inhibition on chronic high intraocular pressure model of rabbit. METHODS:Totally 24 healthy New Zealand rabbits were randomly divided into 4 groups: normal control group(A group; high intraocular pressure model blank group(B group; high intraocular pressure model with GSTT treated group(C group; high intraocular pressure model with Erigeron brevicapas hand mass(EBHMtreated group(D group. High intraocular pressure model was induced by 20g/L methylcellulose injection into the anterior chamber in B group, C group and D group. D group was injected 5 mg/kg GSTT and C group was injected 4.5mg/kg EBHM and measured intraocular pressure with Schiotz tonometer every day for 4 weeks. The retina tissue superoxide dismutase(SODand maleic dialdehyde(MDAcontent were detected 28 days later. RESULTS: After glaucoma model of rabbit eyes were established, the intraocular pressure during observation period was maintained in 32-39mmHg; High intraocular pressure model blank group and normal control group, EBHM treatment group, GSTT treatment group were compared, the differences of retina MDA, SOD content had statistical significance(P0.05; EBHM treatment group, GSTT treatment group and normal control group were compared, the content of MDA in the retina was still slightly higher(P<0.05, the content of SOD slightly lower(P<0.05 CONCLUSION: GSTT can effectively improve the retina SOD activity of chronic high intraocular pressure in rabbit and reduce the content of MDA, which has a protective effect of persistent high intraocular retinal oxidative stress.

  13. Acute Central Retinal Artery Occlusion Associated with Intraocular Silicone Oil Tamponade

    Directory of Open Access Journals (Sweden)

    Mehmet Yasin Teke

    2012-05-01

    Full Text Available Many systemic and ocular factors may cause acute central retinal artery occlusion (CRAO. Herein, we aimed to describe a case of CRAO due to intraocular silicone oil (SO tamponade. To the best of our knowledge, a case like our has not been reported previously. A 58-yearold male patient had undergone combined pars plana vitrectomy-lensectomy and intraocular SO for lens luxation and vitreus hemorrhage associated with a blunt ocular trauma in his right eye. Two weeks after the surgery, he presented with acute vision loss in the same eye. He was diagnosed with acute CRAO and it should be related with mechanical press or raised intraocular pressure (IOP associated with SO. He was treated by partial removal of SO immediately. In spite of the regression of retina edema, his visual acuity did not improve due to optic atrophy. SO may cause CRAO due to raised IOP and/or its mechanical pressure and this complication must be kept in mind. (Turk J Oph thal mol 2012; 42: 238-40

  14. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.

    Science.gov (United States)

    Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao

    2018-06-01

    We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.

  15. Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry Efeito das lentes intraoculares asféricas e com pigmentação amarela na campimetria azul-amarelo

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2012-10-01

    Full Text Available PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes received ultraviolet and blue light filter (yellow tinted IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD] investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.OBJETIVO: Investigar a possibilidade de efeitos na sensibilidade ao contraste e nos resultados da campimetria azul-amarelo com implante de uma lente intraocular (LIO asférica ou de pigmentação amarela. MÉTODOS: Trata-se de um estudo prospectivo, randomizado, duplo-mascarado, envolvendo 52 pacientes portadores de catarata senil bilateral, divididos em dois grupos; 25

  16. Ocular Onchocerciasis in the Yanomami Communities from Brazilian Amazon: Effects on Intraocular Pressure

    OpenAIRE

    Herzog-Neto, Guilherme; Jaegger, Karen; do Nascimento, Erika S.; Marchon-Silva, Verônica; Banic, Dalma M.; Maia-Herzog, Marilza

    2014-01-01

    To determine the influence of onchocercal eye disease on the intraocular pressure of the Yanomami Tribe Aratha-ú of Roraima State, Brazil, considered endemic for onchocerciasis, a total of 86 patients were submitted to an ophthalmologic exam that included external examination, slit lamp examination, intraocular pressure measurement, and a fundus ophthalmoscope examination. A high prevalence of onchocerciasis-related eye lesions was encountered in 68.6% of the patients. Punctate keratitis and ...

  17. Intraocular osseous metaplasia. A clinico-pathological study.

    Science.gov (United States)

    Vemuganti, Geeta K; Honavar, Santosh G; Jalali, Subhadra

    2002-09-01

    To evaluate the clinico-pathologic features of intraocular osseous metaplasia. Pathology specimens of enucleated eyes submitted to the ophthalmic pathology service at a tertiary eye-care referral center between January 1995 and June 1999 were studied for intraocular osseous metaplasia. Specific histopathologic features noted in specimens with osseous metaplasia were the presence of retinal detachment, gliosis, retinal pigment epithelial hyperplasia, drusen, epiretinal membrane, fibrovascular proliferation and inflammation. Immunohistochemistry using monoclonal antibody against glial fibrillary acidic protein was performed to assess the glial component within the membranes and the proliferative vitreoretinal mass. Clinical records were reviewed and correlated with histopathologic findings. Osseous metaplasiaS was noted in 8 of 151 (5.2%) eyes examined. Clinical diagnosis in these was phthisis bulbi, staphyloma, absolute glaucoma and microphthalmos. Enucleation was performed for relief of symptoms (in painful blind eyes) or for cosmesis, and in an eye inciting sympathetic ophthalmia. Retinal detachment, gliosis and retinal pigment epithelial hyperplasia were noted in all the cases. Drusen with calcification or ossification (5 of 8), fibrovascular proliferation in the vitreous (5 of 8) and active inflammation (4 of 8) were the other associated histologic features. Location of ossification was subretinal in 3 cases, preretinal (ora serrata) in 1 case and in both locations in 4 cases. The eyes with subretinal osseous metaplasia had associated calcified drusen, while preretinal ossification was seen within the fibrovascular membranes. Chronic retinal detachment, hyperplasia and transdifferentiation of retinal pigment epithelium appear to be a few of the prerequisites for intraocular osseous metaplasia. Ossification can occur at isolated subretinal and preretinal locations or can involve both. Though a larger study is required to postulate the chronology of events, in

  18. Intraocular osseous metaplasia. A clinico-pathological study

    Directory of Open Access Journals (Sweden)

    Vemuganti Geeta

    2002-01-01

    Full Text Available Purpose: To evaluate the clinico-pathologic features of intraocular osseous metaplasia. Methods: Pathology specimens of enucleated eyes submitted to the ophthalmic pathology service at a tertiary eye-care referral center between January 1995 and June 1999 were studied for intraocular osseous metaplasia. Specific histopathologic features noted in specimens with osseous metaplasia were the presence of retinal detachment, gliosis, retinal pigment epithelial hyperplasia, drusen, epiretinal membrane, fibrovascular proliferation and inflammation. Immunohistochemistry using monoclonal antibody against glial fibrillary acidic protein was performed to assess the glial component within the membranes and the proliferative vitreoretinal mass. Clinical records were reviewed and correlated with histopathologic findings. Results: Osseous metaplasiaS was noted in 8 of 151 (5.2% eyes examined. Clinical diagnosis in these was phthisis bulbi, staphyloma, absolute glaucoma and microphthalmos. Enucleation was performed for relief of symptoms (in painful blind eyes or for cosmesis, and in an eye inciting sympathetic ophthalmia. Retinal detachment, gliosis and retinal pigment epithelial hyperplasia were noted in all the cases. Drusen with calcification or ossification (5 of 8, fibrovascular proliferation in the vitreous (5 of 8 and active inflammation (4 of 8 were the other associated histologic features. Location of ossification was subretinal in 3 cases, preretinal (ora serrata in 1 case and in both locations in 4 cases. The eyes with subretinal osseous metaplasia had associated calcified drusen, while preretinal ossification was seen within the fibrovascular membranes. Conclusion: Chronic retinal detachment, hyperplasia and transdifferentiation of retinal pigment epithelium appear to be a few of the prerequisites for intraocular osseous metaplasia. Ossification can occur at isolated subretinal and preretinal locations or can involve both. Though a larger study is

  19. On the retinal toxicity of intraocular glucocorticoids.

    Science.gov (United States)

    Torriglia, Alicia; Valamanesh, Fatemeh; Behar-Cohen, Francine

    2010-12-15

    Corticosteroids are hormones involved in many physiological responses such as stress, immune modulation, protein catabolism and water homeostasis. The subfamily of glucocorticoids is used systemically in the treatment of inflammatory diseases or allergic reactions. In the eye, glucocorticoides are used to treat macular edema, inflammation and neovascularization. The most commonly used glucocorticoid is triamcinolone acetonide (TA). The pharmaceutical formulation of TA is not adapted for intravitreal administration but has been selected by ophthalmologists because its very low intraocular solubility provides sustained effect. Visual benefits of intraocular TA do not clearly correlate with morpho-anatomical improvements, suggesting potential toxicity. We therefore studied, non-common, but deleterious effects of glucocorticoids on the retina. We found that the intravitreal administration of TA is beneficial in the treatment of neovascularization because it triggers cell death of endothelial cells of neovessels by a caspase-independent mechanism. However, this treatment is toxic for the retina because it induces a non-apoptotic, caspase-independent cell death related to paraptosis, mostly in the retinal pigmented epithelium cells and the Müller cells. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. Retropupillary Fixation of Iris-Claw Intraocular Lens for Aphakic Eyes in Children.

    Directory of Open Access Journals (Sweden)

    Martina Brandner

    Full Text Available To report outcome, complications and safety of retropupillary fixated iris-claw intraocular lenses in a pediatric population.Retrospective study.Ten consecutive pediatric patients (15 eyes underwent placement of retropupillary fixated iris-claw intraocular lenses between October 2007 and July 2013 at the Department of Ophthalmology, Medical University Graz and General Hospital Klagenfurt, Austria. Postoperative visual acuity and complications were analyzed.Median final best-corrected visual acuity improved by 0.12 logMAR from preoperative baseline. Mean postoperative spherical equivalent was -0.05 ± 1.76 D. No serious complications were observed intra- or postoperatively during the entire follow-up period of up to 40 months. One patient experienced a haptic disenclavation with IOL subluxation immediately after a car accident.Our study demonstrates that iris-claw intraocular lens implantation behind the iris is safe in children with lack of capsular support and yields excellent visual outcome with low complication rate.

  1. Retropupillary Fixation of Iris-Claw Intraocular Lens for Aphakic Eyes in Children

    Science.gov (United States)

    Brandner, Martina; Thaler-Saliba, Sarah; Plainer, Sophie; Vidic, Bertram; El-Shabrawi, Yosuf; Ardjomand, Navid

    2015-01-01

    Purpose To report outcome, complications and safety of retropupillary fixated iris-claw intraocular lenses in a pediatric population. Design Retrospective study. Patients and Methods Ten consecutive pediatric patients (15 eyes) underwent placement of retropupillary fixated iris-claw intraocular lenses between October 2007 and July 2013 at the Department of Ophthalmology, Medical University Graz and General Hospital Klagenfurt, Austria. Postoperative visual acuity and complications were analyzed. Results Median final best-corrected visual acuity improved by 0.12 logMAR from preoperative baseline. Mean postoperative spherical equivalent was -0.05 ± 1.76 D. No serious complications were observed intra- or postoperatively during the entire follow-up period of up to 40 months. One patient experienced a haptic disenclavation with IOL subluxation immediately after a car accident. Conclusion Our study demonstrates that iris-claw intraocular lens implantation behind the iris is safe in children with lack of capsular support and yields excellent visual outcome with low complication rate. PMID:26110864

  2. Anti-tubercular therapy for intraocular tuberculosis: A systematic review and meta-analysis.

    Science.gov (United States)

    Kee, Ae Ra; Gonzalez-Lopez, Julio J; Al-Hity, Aws; Gupta, Bhaskar; Lee, Cecilia S; Gunasekeran, Dinesh Visva; Jayabalan, Nirmal; Grant, Robert; Kon, Onn Min; Gupta, Vishali; Westcott, Mark; Pavesio, Carlos; Agrawal, Rupesh

    2016-01-01

    Intraocular tuberculosis remains a diagnostic and management conundrum for both ophthalmologists and pulmonologists. We analyze the efficacy and safety of anti-tubercular therapy (ATT) in patients with intraocular tuberculosis and factors associated with favorable outcome. Twenty-eight studies are included in this review, with a total of 1,917 patients. Nonrecurrence of inflammation was observed in pooled estimate of 84% of ATT-treated patients (95% CI 79-89). There was minimal difference in the outcome between patients treated with ATT alone (85% successful outcome; 95% CI 25-100) and those with concomitant systemic corticosteroid (82%; 95% CI 73-90). The use of ATT may be of benefit to patients with suspected intraocular tuberculosis; however, this conclusion is limited by the lack of control group analysis and standardized recruitment and treatment protocols. We propose further prospective studies to better establish the efficacy of ATT and ascertain the factors associated with favorable treatment outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Intraocular pressure menagement with transpalpebral tonometry

    OpenAIRE

    Toker, Mustafa İlker; Dursun, Ayhan

    2013-01-01

    Applanation tonometry is the method of measuring intraocular pressure (IOP) with instruments the corneal surface. The Goldmann applanation tonometer (GAT) is regarded as the “gold standard’’ of measuring IOP. An irregular and opaque corneal surface compromises IOP measurement by Goldmann applanation tonometry. In such cases accurate measurement without corneal contact would be applicable. The transpalpebral tonometer is new method and measures IOP without corneal contact through the eyelid....

  4. Liquid-crystal intraocular adaptive lens with wireless control

    NARCIS (Netherlands)

    Simonov, A.N.; Vdovine, G.V.; Loktev, M.

    2007-01-01

    We present a prototype of an adaptive intraocular lens based on a modal liquid-crystal spatial phase modulator with wireless control. The modal corrector consists of a nematic liquid-crystal layer sandwiched between two glass substrates with transparent low- and high-ohmic electrodes, respectively.

  5. Clinical analysis of modified trabeculectomy in glaucoma surgery with high elevated intraocular pressure

    Directory of Open Access Journals (Sweden)

    Cang-Xia Zhang

    2013-10-01

    Full Text Available AIM: To make a retrospective analysis of the clinical data of modified trabeculectomy in treating glaucoma surgery with high elevated intraocular pressure retrospectively and evaluate the effect of modified trabeculectomy.METHODS:One hundred acute angle-closure glaucoma patients(100 eyeswith persistent high intraocular pressure were divided into treatment group(45 eyesand control group(55 eyes. Patients in treatment group was treated with by trabeculectomy, while those in control group received modified trabeculectomy. The modified measures include stellate ganglion block preoperative, topical anesthesia and local anesthesia with 20g/L lidocaine cotton-piece, to make scleral flap with sclerotome, to release aqueous humor outflow slowly after paracentesis of anterior chamber, and using mydriatic and cycloplegic during and after surgery.RESULTS: The incidence of operation complicationin control group was lower than that in treatment group. The differences were statistically significant(Pt=9.1535, Pt=39.8010, Pt=11.3219, PCONCLUSION: The modified trabeculectomy applied in the treatment of glaucoma with persistent high intraocular pressure can not only save the visual function of connection part to a certain extent, but also reduce the incidence of serious complications. It can obtain better intraocular pressure, shorten the average hospitalization days, decrease the expenses and increase patients satisfaction.

  6. Changes in intraocular pressure and horizontal pupil diameter ...

    African Journals Online (AJOL)

    The objective of this study was to determine the effects of topical 0.5% tropicamide, 1% atropine sulphate and 10% phenylephrine hydrochloride ophthalmic solutions on intraocular pressure (IOP) and horizontal pupil diameter (HPD) in the dog during the first hour after treatment. Forty clinically and ophthalmologically ...

  7. Visual outcome with the Oculentis Mplus intraocular lens

    Directory of Open Access Journals (Sweden)

    Si-Yuan Liu

    2017-11-01

    Full Text Available AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL.METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOLwere as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications. RESULTS: At 3mo after surgery, distance visual acuity of test group with Oculentis Mplus IOL were 0.10±0.03,the difference with control group was not significant(t=1.74, P>0.05. Eyes in test group had an uncorrected near acuity 0.11±0.04, the difference with control group was significant(t=15.53, PCONCLUSION: The implantation of Oculentis Mplus IOL not only has a good distance uncorrected visual acuity, but also with better near visual acuity. The surgery is safe, reliable and no special complication induced.

  8. An ultralow power wireless intraocular pressure monitoring system

    International Nuclear Information System (INIS)

    Liu Demeng; Mei Niansong; Zhang Zhaofeng

    2014-01-01

    This paper describes an ultralow power wireless intraocular pressure (IOP) monitoring system that is dedicated to sensing and transferring intraocular pressure of glaucoma patients. Our system is comprised of a capacitive pressure sensor, an application-specific integrated circuit, which is designed on the SMIC 180 nm process, and a dipole antenna. The system is wirelessly powered and demonstrates a power consumption of 7.56 μW at 1.24 V during continuous monitoring, a significant reduction in active power dissipation compared to existing work. The input RF sensitivity is −13 dBm. A significant reduction in input RF sensitivity results from the reduction of mismatch time of the ASK modulation caused by FM0 encoding. The system exhibits an average error of ± 1.5 mmHg in measured pressure. Finally, a complete IOP system is demonstrated in the real biological environment, showing a successful reading of the pressure of an eye. (semiconductor integrated circuits)

  9. INTRAOCULAR AND SERUM LEVELS OF VASCULAR ENDOTHELIAL GROWTH FACTOR IN ACUTE RETINAL NECROSIS AND OCULAR TOXOPLASMOSIS

    NARCIS (Netherlands)

    Wiertz, Karin; De Visser, Lenneke; Rijkers, Ger; De Groot-Mijnes, Jolanda; Los, Leonie; Rothova, Aniki

    2010-01-01

    Purpose: To determine the intraocular and serum vascular endothelial growth factor (VEGF) levels in patients with acute retinal necrosis (ARN) and compare those with VEGF levels found in patients with ocular toxoplasmosis (OT). Methods: Paired intraocular fluid and serum samples of 17 patients with

  10. Intraocular Pressure in Pregnant and Non-Pregnant Nigerian Women

    African Journals Online (AJOL)

    Erah

    . ... ocular diseases and these were used as the exclusion ... between groups with student's t-test. ... SD = standard deviation, SEM = standard error of mean, N= .... 38(4):229-34. 26. Qureshi IA. Intraocular pressure and pregnancy. Clin. Med.

  11. Systems genetics identifies a role for Cacna2d1 regulation in elevated intraocular pressure and glaucoma susceptibility

    OpenAIRE

    Chintalapudi, Sumana R.; Maria, Doaa; Di Wang, Xiang; Bailey, Jessica N. Cooke; Hysi, Pirro G.; Wiggs, Janey L.; Williams, Robert W.; Jablonski, Monica M.

    2017-01-01

    textabstractGlaucoma is a multi-factorial blinding disease in which genetic factors play an important role. Elevated intraocular pressure is a highly heritable risk factor for primary open angle glaucoma and currently the only target for glaucoma therapy. Our study helps to better understand underlying genetic and molecular mechanisms that regulate intraocular pressure, and identifies a new candidate gene, Cacna2d1, that modulates intraocular pressure and a promising therapeutic, pregabalin, ...

  12. Cambios de la presión intraocular en pacientes con hipertensión arterial

    Directory of Open Access Journals (Sweden)

    G. Tenorio-Guajardo

    2014-07-01

    Conclusiones: En este estudio se encontró correlación entre presión intraocular y la presión arterial diastólica, pero no se encontró correlación entre la sistólica. Es recomendable vigilar la presión intraocular en pacientes hipertensos, especialmente en aquellos con hipertensión diastólica persistente y con antecedentes familiares de glaucoma.

  13. Photodynamic therapy of intraocular cancers

    International Nuclear Information System (INIS)

    Gravier, N.; Duvournau, Y.; Querec, M.A.; Pechereau, A.; Patrice, T.

    1992-01-01

    The most common intraocular tumors are choroidal malignant melanomas (70%) and retinoblastomas (13%). Each time that visual acuity is preserved, various conservative treatments are considered relative to the potential risk of metastatic disease during enucleation. In addition to standard techniques, photodynamic therapy is a potentially attractive new approach limited in its effects to the area of the treated tumor. The purpose of this preclinical study is to determine a reference dose-effect for single laser doses and to study effects of fractionation of the laser dose. (author). 9 refs., 1 tab

  14. Visual performance after the implantation of a new trifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Vryghem JC

    2013-10-01

    Full Text Available Jérôme C Vryghem,1,2 Steven Heireman1,21Brussels Eye Doctors, Brussels, Belgium; 2Clinique Saint-Jean, Brussels, BelgiumPurpose: To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens.Methods: A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients.Results: The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09. LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced.Conclusion: The introduction of a third focus in diffractive multifocal

  15. Method for producing an isoplanatic aspheric monofocal intraocular lens, and resul ting lens

    OpenAIRE

    Barbero, Sergio; Marcos, Susana; Dorronsoro, Carlos; Montejo, Javier; Salazar Salegui, Pedro

    2010-01-01

    [EN] The invention can be used to obtain isoplanatic aspheric mono focal intraocular lenses in a viewing range of up to 25° (preferably up to 10°). The method comprises the following steps: l. mathematical defmition of an aphakic eye model; 2. mathematical definition of an intraocular lens model; 3. mathematical defmition of the implantation of the lens; 4. mathematical defmition of the merit function; 5. definition of the contour conditions; 6. defmition of a measurement for charact...

  16. Intraocular pressure-lowering effect of oral paracetamol and its in vitro corneal penetration properties

    Directory of Open Access Journals (Sweden)

    Mohamed N

    2013-01-01

    Full Text Available Nabiel Mohamed, David MeyerDivision of Ophthalmology, Faculty of Medicine and Health Sciences, University of Stellenbosch, Cape Town, South AfricaBackground: Several studies have confirmed the ability of cannabinoids to reduce intraocular pressure. Experimental data recently demonstrated unequivocally that the analgesic effect of paracetamol is due to its indirect action on cannabinoid receptors. The question then arises as to whether paracetamol can reduce intraocular pressure via its effect on intraocular cannabinoid receptors.Methods: A 2-week, prospective, randomized, controlled, single-center, parallel-group pilot study was carried out to determine the efficacy and safety of paracetamol 1 g orally administered every 6 hours in adult patients with primary or secondary open angle glaucoma as compared with topical levobunolol 0.5% twice a day. Patient well-being was closely monitored throughout the study and focused on hepatic safety in accordance with Drug-Induced Liver Injury Network criteria. The in vitro diffusion kinetics of acetaminophen in a phosphate-buffered solution in rabbit and human corneas was also investigated, with the view to a topical application.Results: Eighteen adult patients were enrolled in the study, with nine in the topical levobunolol group and nine in the oral paracetamol group. In the levobunolol group, the mean reduction in intraocular pressure at day 7 was 7.5 mmHg (P < 0.008 and at day 14 was 9.1 mmHg (P < 0.005, from a mean baseline intraocular pressure of 29.6 mmHg. The corresponding figures for the paracetamol group were 8.8 mmHg (P < 0.0004 at day 7 and 6.5 mmHg (P < 0.004 at day 14, from a mean baseline intraocular pressure of 29.4 mmHg. Both study regimens were well tolerated. No serious treatment-related adverse events were reported in either of the treatment groups. Liver function tests, systolic/diastolic blood pressure, or heart rate remained unchanged in both groups during the 2 weeks of the study. In

  17. Bartonella and intraocular inflammation: a series of cases and review of literature

    Directory of Open Access Journals (Sweden)

    Kalogeropoulos C

    2011-06-01

    Full Text Available Chris Kalogeropoulos1, Ioannis Koumpoulis1, Andreas Mentis2, Chrisavgi Pappa1, Paraskevas Zafeiropoulos1, Miltiadis Aspiotis11Department of Ophthalmology, Medical School, University of Ioannina, Greece; 2Laboratory of Medical Microbiology, Hellenic Pasteur Institute, Athens, GreecePurpose: To present various forms of uveitis and/or retinal vasculitis attributed to Bartonella infection and review the impact of this microorganism in patients with uveitis.Methods: Retrospective case series study. Review of clinical records of patients diagnosed with Bartonella henselae and Bartonella quintana intraocular inflammation from 2001 to 2010 in the Ocular Inflammation Department of the University Eye Clinic, Ioannina, Greece. Presentation of epidemiological and clinical data concerning Bartonella infection was provided by the international literature.Results: Eight patients with the diagnosis of Bartonella henselae and two patients with B. quintana intraocular inflammation were identified. Since four patients experienced bilateral involvement, the affected eyes totaled 14. The mean age was 36.6 years (range 12–62. Uveitic clinical entities that we found included intermediate uveitis in seven eyes (50%, vitritis in two eyes (14.2%, neuroretinitis in one eye (7.1%, focal retinochoroiditis in one eye (7.1%, branch retinal vein occlusion (BRVO due to vasculitis in one eye (7.1%, disc edema with peripapillary serous retinal detachment in one eye (7.1%, and iridocyclitis in one eye (7.1%. Most of the patients (70% did not experience systemic symptoms preceding the intraocular inflammation. Antimicrobial treatment was efficient in all cases with the exception of the case with neuroretinitis complicated by anterior ischemic optic neuropathy and tubulointerstitial nephritis.Conclusion: Intraocular involvement caused not only by B. henselae but also by B. quintana is being diagnosed with increasing frequency. A high index of suspicion is needed because the

  18. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Ugur Unsal

    2016-01-01

    Full Text Available Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p=0.50 and p=0.509, resp.. The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p=0.049, p=0.005, and p=0.001, resp. and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p=0.001. The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities, whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading.

  19. Systems genetics identifies a role for Cacna2d1 regulation in elevated intraocular pressure and glaucoma susceptibility.

    Science.gov (United States)

    Chintalapudi, Sumana R; Maria, Doaa; Di Wang, Xiang; Bailey, Jessica N Cooke; Hysi, Pirro G; Wiggs, Janey L; Williams, Robert W; Jablonski, Monica M

    2017-11-24

    Glaucoma is a multi-factorial blinding disease in which genetic factors play an important role. Elevated intraocular pressure is a highly heritable risk factor for primary open angle glaucoma and currently the only target for glaucoma therapy. Our study helps to better understand underlying genetic and molecular mechanisms that regulate intraocular pressure, and identifies a new candidate gene, Cacna2d1, that modulates intraocular pressure and a promising therapeutic, pregabalin, which binds to CACNA2D1 protein and lowers intraocular pressure significantly. Because our study utilizes a genetically diverse population of mice with known sequence variants, we are able to determine that the intraocular pressure-lowering effect of pregabalin is dependent on the Cacna2d1 haplotype. Using human genome-wide association study (GWAS) data, evidence for association of a CACNA2D1 single-nucleotide polymorphism and primary open angle glaucoma is found. Importantly, these results demonstrate that our systems genetics approach represents an efficient method to identify genetic variation that can guide the selection of therapeutic targets.

  20. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Wei Ching-Kuo

    2012-10-01

    Full Text Available Abstract Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  1. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses.

    Science.gov (United States)

    Wei, Ching-Kuo; Wang, Shun-Mu; Lin, Jen-Chieh

    2012-10-29

    The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients' decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one's own expense, overall patient satisfaction and postoperative visual clarity. The results showed that the patient's gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  2. Lente intra-ocular opaca em diplopia intratável: relato de caso Opaque intraocular lens in intractable diplopia: case report

    Directory of Open Access Journals (Sweden)

    Fernanda Teixeira Krieger

    2006-08-01

    Full Text Available Diplopia intratável tem sido descrita em várias situações. Métodos convencionais como prismas e correção cirúrgica do estrabismo falham em neutralizá-la. O objetivo do trabalho é documentar o caso de uma paciente com estrabismo de longa data, cuja diplopia deteriorou-se ao longo dos anos, e não foi possível resolução com cirurgia, prisma, e oclusão com óculos e lente de contato com pupila opaca. A paciente foi então submetida à facoemulsificação com implante de lente intra-ocular opaca que atingiu o objetivo desejado.Intractable diplopia has been described in many situations but poor results are the rule with standard treatment modalities. The authors report a case of a woman with long-standing strabismus and diplopia who failed to improve following surgery, prism, and occlusive spectacles or contact lenses. Then, she was submitted to phacoemulsification and opaque intraocular lens implantation, which successfully neutralized diplopia.

  3. Experimental differentiation of intraocular masses using ultrahigh-field magnetic resonance imaging--a case series.

    Directory of Open Access Journals (Sweden)

    Karen Falke

    Full Text Available PURPOSE: The case reports presented here were compiled to demonstrate the potential for improved diagnosis and monitoring of disease progress of intraocular lesions using ultrahigh-field magnetic resonance microscopy (MRM at 7.1 Tesla. METHODS: High-resolution ex vivo ocular magnetic resonance (MR images were acquired on an ultrahigh-field MR system (7.1 Tesla, ClinScan, Bruker BioScan, Germany using a 2-channel coil with 4 coil elements and T2-weighted turbo spin echo (TSE sequences of human eyes enucleated because of different intraocular lesions. Imaging parameters were: 40×40 mm field of view, 512×512 matrix, and 700 µm slice thickness. The results were correlated with in vivo ultrasound and histology of the enucleated eyes. RESULTS: Imaging was performed in enucleated eyes with choroidal melanoma, malignant melanoma of iris and ciliary body with scleral perforation, ciliary body melanoma, intraocular metastasis of esophageal cancer, subretinal bleeding in the presence of perforated corneal ulcer, hemorrhagic choroidal detachment, and premature retinopathy with phthisis and ossification of bulbar structures. MR imaging allowed differentiation between solid and cystic tumor components. In case of hemorrhage, fluid-fluid levels were identified. Melanin and calcifications caused significant hypointensity. Microstructural features of eye lesions identified by MRM were confirmed by histology. CONCLUSION: This study demonstrates the potential of MRM for the visualization and differential diagnosis of intraocular lesions. At present, the narrow bore of the magnet still limits the use of this technology in humans in vivo. Further advances in ultrahigh-field MR imaging will permit visualization of tumor extent and evaluation of nonclassified intraocular structures in the near future.

  4. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Robert Koprowski

    2017-01-01

    Full Text Available Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05. The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05. When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3. Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.

  5. Cerebral migration of intraocular silicone oil: an MRI study

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Milea, Dan; Løgager, Vibeke

    2011-01-01

    for retinal detachment. Methods: Nineteen patients included in this study were referred for silicone oil removal after uncomplicated retinal detachment surgery using internal silicone oil tamponade. Patients with a previous history of intraocular silicone oil, glaucoma or optic pit were excluded. After...

  6. Exact quantization conditions, toric Calabi-Yau and non-perturbative topological string

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kaiwen [Department of Mathematics, University of Science and Technology of China,96 Jinzhai Road, Hefei, Anhui 230026 (China); Wang, Xin; Huang, Min-xin [Interdisciplinary Center for Theoretical Study,Department of Modern Physics, University of Science and Technology of China,96 Jinzhai Road, Hefei, Anhui 230026 (China)

    2017-01-16

    We establish the precise relation between the Nekrasov-Shatashvili (NS) quantization scheme and Grassi-Hatsuda-Mariño conjecture for the mirror curve of arbitrary toric Calabi-Yau threefold. For a mirror curve of genus g, the NS quantization scheme leads to g quantization conditions for the corresponding integrable system. The exact NS quantization conditions enjoy a self S-duality with respect to Planck constant ℏ and can be derived from the Lockhart-Vafa partition function of non-perturbative topological string. Based on a recent observation on the correspondence between spectral theory and topological string, another quantization scheme was proposed by Grassi-Hatsuda-Mariño, in which there is a single quantization condition and the spectra are encoded in the vanishing of a quantum Riemann theta function. We demonstrate that there actually exist at least g nonequivalent quantum Riemann theta functions and the intersections of their theta divisors coincide with the spectra determined by the exact NS quantization conditions. This highly nontrivial coincidence between the two quantization schemes requires infinite constraints among the refined Gopakumar-Vafa invariants. The equivalence for mirror curves of genus one has been verified for some local del Pezzo surfaces. In this paper, we generalize the correspondence to higher genus, and analyze in detail the resolved ℂ{sup 3}/ℤ{sub 5} orbifold and several SU(N) geometries. We also give a proof for some models at ℏ=2π/k.

  7. Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

    Science.gov (United States)

    Vincent, Stephen J; Vincent, Roslyn A; Shields, David; Lee, Graham A

    2012-01-01

    To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. One hundred nine (54 males : 55 females) patients including only eyes under medical treatment for glaucoma. Measurement by Goldmann applanation tonometry, iCare rebound tonometry and 7CR non-contact tonometry. Intraocular pressure. There were strong correlations between the intraocular pressure measurements obtained with Goldmann and both the rebound and non-contact tonometers (Spearman r-values ≥ 0.79, P tonometer. For the rebound tonometer, the mean intraocular pressure was slightly higher compared with the Goldmann applanation tonometer in the right eyes (P = 0.02), and similar in the left eyes (P = 0.93); however, these differences did not reach statistical significance. The Goldmann correlated measurements from the non-contact tonometer were lower than the average Goldmann reading for both right (P 0.01) eyes. The corneal compensated measurements from the non-contact tonometer were significantly higher compared with the other tonometers (P ≤ 0.001). The iCare rebound tonometer and the 7CR non-contact tonometer measure intraocular pressure in fundamentally different ways to the Goldmann applanation tonometer. The resulting intraocular pressure values vary between the instruments and will need to be considered when comparing clinical versus home acquired measurements. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  8. A study of Brachytherapy for Intraocular Tumor

    International Nuclear Information System (INIS)

    Ji, Kwang Soo; Yoo, Dae Hyun; Lee, Sung Goo; Kim, Jae Hu; Ji, Young Hun

    1996-01-01

    The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm Maximum error is -11.3% and 0.8 mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192

  9. [Contemporary possibilities of intraocular pressure measurement].

    Science.gov (United States)

    Hornová, J; Baxant, A

    2013-10-01

    Authors introduced current possibilities of measuring intraocular pressure (IOP). A list of available methods of monitoring IOP is published; contact measurement method IOP directly on the cornea, but also over upper lid, methodology of minimal contact and non-contact measurement. Following contact methods are described; former measurements of IOP by impression Schiotz tonometer and the current methodology applanation. So far as the gold standard measurement Goldmann applanation tonometer (GAT) is considered, another methodology with applanation measurements are compared: Pascal dynamic contoured tonometer (DCT ), BioResonator - resonant applanation tonometer (ART ), digital applanation tonometer Tonopen and last hit: continuous measurement of IOP by Sensimed Triggerfish. Orientation and rapid assessment is palpation pressure control over the lid and measuring by tonometer Diaton. Rebound tonometer (RBT) iCare belongs to measurements with minimal contact, no need anesthetic drops and fluorescein, therefore a self - home version of IOP measurements (Icare ONE) is developed. Non-contact measurement of IOP by different pneumotonometers is popular for screening assessment of IOP. Reichert Ocular Response Analyzer (ORA) is a non-contact applanation IOP measurement and reveals additional properties of the cornea. In the discussion of a range methodology is evaluated, the experience of other authors and their own experience is compared. For monitoring of patients is necessary to select the most suitable methodology, measure repeatedly and accurately to allow long-term monitoring of intraocular pressure.

  10. Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure

    Science.gov (United States)

    Sinha, D.N.; Wray, W.O.

    1994-12-27

    The apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established. 3 figures.

  11. A STUDY OF CASE SERIES OF INTRAOCULAR FOREIGN BODIES IN A TERTIARY CARE CENTER IN SOUTH INDIA

    Directory of Open Access Journals (Sweden)

    Shilpa Y. D

    2017-09-01

    Full Text Available BACKGROUND Intraocular foreign bodies can cause vision threatening complication in cases of penetrating ocular injuries. Ocular injuries can occur anywhere at work place, at home, due to road traffic accidents, etc. Accidental eye injuries are common in males in work place. Awareness about using protective eye wear is required at work places where injuries are common. The aim of the study is to study the demographic profile, visual and anatomical outcome in patients presenting with posterior segment Intraocular Foreign Bodies (IOFB undergoing vitrectomy. MATERIALS AND METHODS Retrospective analysis was done on patients who underwent pars plana vitrectomy for posterior segment IOFB from March 2014 to April 2017. Complete ocular examination, B scan ultrasonography and x-ray orbit were done in all cases and retained posterior segment intraocular foreign body confirmed. Intraoperative difficulties, anatomical and visual outcome and postoperative complications were studied. RESULTS Cases with posterior segment intraocular foreign body and endophthalmitis had poor visual and anatomical outcome. Patients who underwent complete vitrectomy with 240 encirclage band with or without tamponade had better visual outcome. CONCLUSION Imaging in the injured eye is important to identify the presence of intraocular foreign body. Planning of the surgical procedure depending on the ocular condition plays a vital role in visual outcome.

  12. Foldable micro coils for a transponder system measuring intraocular pressure

    Energy Technology Data Exchange (ETDEWEB)

    Ullerich, S.; Schnakenberg, U. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1; Mokwa, W. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1]|[Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany); Boegel, G. vom [Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany)

    2001-07-01

    A foldable transponder system consisting of a chip and a micro coil for measuring intraocular pressure continuously is presented. The system will be integrated in the haptic of a soft artificial intraocular lens. Calculations of planar micro coils with 6 mm and 10.3 mm in diameter show the limits for planar coils with an outer diameter of 6 mm. For the realisation of the transponder system a 20 {mu}m thick coil with an outer diameter of 10.3 mm, an inner diameter of 7.7 mm, 16 turns and a gap of 20 {mu}m between the windings was selected. Measurements show a good agreement between calculated and measured values. Wireless pressure measurements were carried out showing a linear behaviour of the output signal with respect to the applied pressure. (orig.)

  13. Bacterial contamination of intraocular lens surgery.

    OpenAIRE

    Vafidis, G C; Marsh, R J; Stacey, A R

    1984-01-01

    One hundred sterile intraocular lenses were placed on the external eye of 50 patients during cataract surgery. Half of the specimens were cultured for bacteria, the other half were examined under the light microscope after fixing and staining. A bacterial contamination rate of 26% was recorded. This is significantly higher than that found in conjunctival swabs (6%) or irrigation specimens (8%) taken at the same time, and higher than that recorded in a group of control lenses (15.2%) exposed t...

  14. Clinical and optical intraocular performance of rotationally asymmetric multifocal IOL plate-haptic design versus C-loop haptic design.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Vega-Estrada, Alfredo

    2013-04-01

    To compare the visual and intraocular optical quality outcomes with different designs of the refractive rotationally asymmetric multifocal intraocular lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) with or without capsular tension ring (CTR) implantation. One hundred thirty-five consecutive eyes of 78 patients with cataract (ages 36 to 82 years) were divided into three groups: 43 eyes implanted with the C-Loop haptic design without CTR (C-Loop haptic only group); 47 eyes implanted with the C-Loop haptic design with CTR (C-Loop haptic with CTR group); and 45 eyes implanted with the plate-haptic design (plate-haptic group). Visual acuity, contrast sensitivity, defocus curve, and ocular and intraocular optical quality were evaluated at 3 months postoperatively. Significant differences in the postoperative sphere were found (P = .01), with a more myopic postoperative refraction for the C-Loop haptic only group. No significant differences were detected in photopic and scotopic contrast sensitivity among groups (P ⩾ .05). Significantly better visual acuities were present in the C-Loop haptic with CTR group for the defocus levels of -2.0, -1.5, -1.0, and -0.50 D (P ⩽.03). Statistically significant differences among groups were found in total intraocular root mean square (RMS), high-order intraocular RMS, and intraocular coma-like RMS aberrations (P ⩽.04), with lower values from the plate-haptic group. The plate-haptic design and the C-Loop haptic design with CTR implantation both allow good visual rehabilitation. However, better refractive predictability and intraocular optical quality was obtained with the plate-haptic design without CTR implantation. The plate-haptic design seems to be a better design to support rotational asymmetric MFIOL optics. Copyright 2013, SLACK Incorporated.

  15. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery

    OpenAIRE

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-01-01

    Abstract Background: Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Methods: Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, ...

  16. Diagnóstico e tratamento do lenticone anterior

    Directory of Open Access Journals (Sweden)

    Ana Luiza Biancardi

    2011-08-01

    Full Text Available Relato de caso de um paciente de 18 anos com sindrome de Alport apresentando perda visual progressiva. A biomicroscopia revelou lenticone anterior bilateral. O paciente realizou tomografia de córnea e segmento anterior com o sistema Scheimpflug (Pentacam e aberrometria e topografia corneana (i-Trace. O paciente foi submetido à facoemulsificação com implante de lente intraocular peça única hidrofóbica (Acrysof® SN60AT. As imagens de Scheimpflug documentaram o lenticone anterior. A aberrometria total mostrou acentuado astigmatismo miópico com acentuada aberração esférica negativa, havendo grande impacto das aberrações de alta ordem (HOA na conversão da letra E de Snellen. O mapa de integração da aberrometria do olho todo com a topografia corneana mostrou maior semelhança das aberrrações totais com as aberrações intraoculares do que com as aberrações da superfície anterior da córnea. Após a cirurgia, o paciente apresentou acuidade visual corrigida igual a 20/20 em ambos os olhos, as imagens de Scheimpflug revelaram lentes intraoculares tópicas e os mapas diferenciais revelaram resolução da miopia e redução das aberrações da alta ordem (total e interna. Os exames de imagem foram úteis para demonstrar o impacto do lenticone anterior na qualidade visual e a resolução das aberrações ópticas após a cirurgia.

  17. Three-year incidence of Nd:YAG capsulotomy and posterior capsule opacification and its relationship to monofocal acrylic IOL biomaterial: a UK Real World Evidence study.

    Science.gov (United States)

    Ursell, Paul G; Dhariwal, Mukesh; Majirska, Katarina; Ender, Frank; Kalson-Ray, Shoshannah; Venerus, Alessandra; Miglio, Cristiana; Bouchet, Christine

    2018-06-11

    To evaluate 3-year incidence of Nd:YAG capsulotomy and PCO and compare the effect of different IOL materials. Data were retrospectively collected from seven UK ophthalmology clinics using Medisoft electronic medical records. Eyes from patients ≥65 years undergoing cataract surgery with implantation of acrylic monofocal IOLs during 2010-2013 and 3-year follow-up were analysed. Nd:YAG capsulotomy and PCO incidence proportions were reported for 3 IOL cohorts: AcrySof, other hydrophobic and hydrophilic acrylic IOLs. Unadjusted/adjusted odds ratios (OR) of Nd:YAG capsulotomy were calculated through logistic regression for non-AcrySof cohorts versus AcrySof. A sub-group analysis in single-piece IOLs (>90% of sample eyes) was also performed. The AcrySof cohort included 13,329 eyes, non-AcrySof hydrophobic 19,025 and non-AcrySof hydrophilic 19,808. The 3-year Nd:YAG capsulotomy incidence (95% CI) for AcrySof (2.4%, 2.2-2.7%) was approximately two times lower than non-AcrySof hydrophobic IOLs (4.4%, 4.1-4.7%) and approximately fourfold lower than non-AcrySof hydrophilic IOLs (10.9%, 10.5-11.3%). Trends were similar in PCO incidence (AcrySof: 4.7%; non-AcrySof hydrophobic: 6.3%; non-AcrySof hydrophilic: 14.8%). Also in the analysis restricted to single-piece IOLs, the pattern remained (2.4% vs 5.1% vs. 10.9%, respectively). Adjusted regression analysis showed a approximately two and fivefold increased odds of Nd:YAG for non-AcrySof hydrophobic and hydrophilic acrylic IOLs respectively vs. AcrySof IOLs. Nd:YAG capsulotomy ORs were similar and remained statistically significant in the single-piece IOL sub-group. Real-world evidence shows that within 3 years following implantation, AcrySof IOLs are significantly superior in reducing Nd:YAG capsulotomy and PCO incidence compared to other hydrophilic and hydrophobic acrylic IOLs.

  18. Comparative study of intraocular pressure (IP in Bangladeshi individuals by contact and non contact technique

    Directory of Open Access Journals (Sweden)

    Sayed Abdul Wadud

    2016-07-01

    Full Text Available Background: Intraocular pressure (IOP is one of the most important parameters in the diagnosis and treatment of glaucoma. Glaucoma has been established as the second leading cause of blindness. The treatment of glaucoma focuses mainly on lowering intraocular pressure (IOP. The target IOP is often set to a level 20% to 30% of IOP reduction, and consequent large IOP reduction beyond 30% or even 40% in cases of advanced glaucoma The different methods of tonometery are: Goldman Applanation tonometery, Noncontact (air-puff tonometery, Perkins tonometery, Tonopen tonometery, Transpalpebral tonometery.Objective: To determine the frequency of accuracy of intraocular pressure (IOP measured by non-contact (air puff tonometer compared with Goldmann applanation tonometer.Methods: This was a non-interventional, cross sectional study conducted at a tertiary care centre of Dhaka, Bangladesh. consecutive subjects attending the BSMMU eye OPD were included in the study. IOP was measured by non-contact (air puff tonometer and a slit lamp mounted GAT in all the subjects. The study samples were selected by convenience sampling who presented for check-up in the Eye Department of community ophthalmology, Bangabandhu Sheikh Mujib Medical University, Dhaka. Bangladesh. Results:A total of 120 eyes in 60 patients were studied. The mean age of the patients was 41.60 year. study population consisted of 24 (40 % men and 36 (60 % women. The mean intraocular pressure was 13.52 &13.72 mmHg for GAT, and 16.64 & 17.44 mmHg for Air puff respectively. The range of measurements by GAT was from 10 to 23 mmHg and by Air puff was 12 to 28mmHg. The difference between IOP measured by two instruments were statistically significant (p=0.000.Conclusion: Airpuff tonometer is quick, a non-contact method to measure intraocular pressure and is useful for screening purposes and postoperative case but the measurements should be confirmed with Goldmann applanation tonometer for accurate labelling

  19. Intraocular surgery in a large diabetes patient population

    DEFF Research Database (Denmark)

    Ostri, Christoffer

    2014-01-01

    The prevalence of diabetes is on the increase in developed countries. Accordingly, the prevention and treatment of vision-threatening diabetic eye complications is assuming greater importance. The overall aim of this thesis is to analyse risk factors for intraocular surgery in a large diabetes po...... surgery, which can be used for preventive purposes, surgical decision-making and patient counselling....

  20. Antireflection coatings for intraocular lenses of sapphire and fianite

    Energy Technology Data Exchange (ETDEWEB)

    Babin, A.A.; Konoplev, Yu.N.; Mamaev, Yu.A. [Inst. of Applied Physics, Nizhnii Novgorod (Russian Federation)] [and others

    1995-10-01

    Broadband antireflection coatings for intraocular lenses of sapphire and fianite are calculated and implemented practically. Their residual reflectance in the liquid with a refracting index of 1.336 is below 0.2% from each face virtually over the entire visible region. 7 refs., 2 figs., 2 tabs.

  1. Straylight from glistenings in intraocular lenses : In vitro study

    NARCIS (Netherlands)

    Łabuz, Grzegorz; Reus, Nicolaas J; van den Berg, Thomas J T P

    PURPOSE: To assess light scattering from intraocular lenses (IOLs) with different numbers of laboratory-induced glistenings and create a model for predicting glistening effects on straylight. SETTING: Rotterdam Ophthalmic Institute, Rotterdam, the Netherlands. DESIGN: Experimental study. METHODS:

  2. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: An updated meta-analysis.

    Science.gov (United States)

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-11-01

    Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16-0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: -1.32, 95% CI = -2.39 to -0.25, P = .015) and estimated PCO score (diff. in means: -2.23; 95% CI, -3.80 to -0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: -0.075; 95% CI, -0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: -0.016; 95% CI, -0.041 to 0.009, P = .208). In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity.

  3. Brachytherapy with cobalt plaques in the conservative treatment of intraocular tumors. The Brazilian experience

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Trippe, N.; Novaes, P.E.; Ferrigno, R.; Fogarolli, R.C.; Maia, M.A.C.; Salvajoli, J.V.; Baraldi, H.E.; Chojniak, M.M.; Erwene, C.M.

    1996-01-01

    Purpose/Objective: To show the retrospective results of intraocular tumors, including uveal melanomas and retinoblastomas treated by exclusive brachytherapy with cobalt plaques. The goal was to keep the vision function with not compromising the chance of cure. Materials and Methods: From December 1989 to December 1993, 76 cases of intraocular tumors, being 56 adult patients with uveal melanomas and 20 children with retinoblastoma, were treated with exclusive intraocular brachytherapy through cobalt plaques. The prescribed dose was 40 Gy, calculated at the apex of the lesion for retinoblastomas and 100 Gy for melanomas. The selection criteria included those introcular lesions with diameter until 15 mm. Results: With the minimum follow up of 24 months, of the 56 patients with uveal melanomas, 41 (73,3%) had their vision preserved with no evidence of disease, while 15 (26,4%) had local failure and were underwent to enucleation. With the medium follow up of 27 months, of the 20 patients with retinoblastoma, 17 (85,5%) had their vision preserved with no evidence of disease, while 3 (15%) had local failure and were underwent to enucleation. All patients are alive with no evidence of systemic disease. Conclusion: When well indicated, the conservative treatment of intraocular tumors with brachytherapy is a good alternative to enucleation and must be done by a multidisciplinary and well trained medical team

  4. Corn silk aqueous extracts and intraocular pressure of systemic and non-systemic hypertensive subjects.

    Science.gov (United States)

    George, Gladys O; Idu, Faustina K

    2015-03-01

    Hypotensive properties have been attributed to the stigma/style of Zea mays L (corn silk). Although the effect of corn silk extract on blood pressure has been documented in animal studies, we are not aware of any study on its effect on human blood pressure and intraocular pressure. A randomised study was carried out on the effect of water only, masked doses of corn silk aqueous extract (60, 130, 192.5 and 260 mg/kg body weight) on intraocular pressure and blood pressure of 20 systemic and 20 non-systemic hypertensive subjects. Intraocular pressure and blood pressure were measured at baseline and every hour for eight hours after administering water or a masked dose of corn silk aqueous extract. Each dose was administered at two-week intervals to each subject in the two study groups. The results showed that the last three doses of corn silk aqueous extract gave a statistically significant reduction (p Corn silk aqueous extract has a lowering effect on intraocular pressure in systemic and non-systemic hypertensive subjects. This may have resulted from the fall in blood pressure that is due to potassium-induced natriuresis and diuresis caused by the high potassium content in the high doses of the corn silk extract. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  5. Socioeconomic and psychological impact of treatment for unilateral intraocular retinoblastoma.

    Science.gov (United States)

    Soliman, S E; Dimaras, H; Souka, A A; Ashry, M H; Gallie, B L

    2015-06-01

    To identify the socioeconomic and psychosocial impacts of clinical treatment decisions for advanced unilateral intraocular retinoblastoma. Retrospective observational case series. institutional study at Alexandria Main University Hospital. records of 66 unilateral retinoblastoma cases treated from May 2005 to May 2013 were retrospectively reviewed. Sixty cases were eligible (International Intraocular Retinoblastoma Classification [IIRC] group C, D or E). two treatment groups were compared: enucleation vs. salvage treatment. Salvage treatment eyes were further subdivided based on IIRC group. Six socioeconomic parameters (financial burden, financial impact, psychological, social, medical and tumor impacts) were scored. Parameter scores ranged from 0 to 3, for overall score range 0 (no adverse impact) to 18 (severe adverse impact). derived Socioeconomic scores were correlated with treatment and outcomes. The enucleation group (28 eyes) had a median overall Socioeconomic score of 4/18, significantly lower than the salvage treatment group (32 eyes), median score 11/18 (PSocioeconomic score varied with IIRC group. Attempted eye salvage failed in 25 children, due to uncontrolled tumor (44%) and socioeconomic impact of cumulative therapies (56%). Treatment duration and Socioeconomic score were higher for the 5 children in the salvage treatment group who developed metastatic disease compared to those without metastasis (Psocioeconomic and psychosocial impacts of attempted ocular salvage for unilateral intraocular retinoblastoma are severe, in comparison to primary enucleation. Primary enucleation is a good treatment for unilateral retinoblastoma. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration.The AGIS Investigators.

    Science.gov (United States)

    2000-10-01

    To investigate the association between control of intraocular pressure after surgical intervention for glaucoma and visual field deterioration. In the Advanced Glaucoma Intervention Study, eyes were randomly assigned to one of two sequences of glaucoma surgery, one beginning with argon laser trabeculoplasty and the other trabeculectomy. In the present article we examine the relationship between intraocular pressure and progression of visual field damage over 6 or more years of follow-up. In the first analysis, designated Predictive Analysis, we categorize 738 eyes into three groups based on intraocular pressure determinations over the first three 6-month follow-up visits. In the second analysis, designated Associative Analysis, we categorize 586 eyes into four groups based on the percent of 6-month visits over the first 6 follow-up years in which eyes presented with intraocular pressure less than 18 mm Hg. The outcome measure in both analyses is change from baseline in follow-up visual field defect score (range, 0 to 20 units). In the Predictive Analysis, eyes with early average intraocular pressure greater than 17.5 mm Hg had an estimated worsening during subsequent follow-up that was 1 unit of visual field defect score greater than eyes with average intraocular pressure less than 14 mm Hg (P =.002). This amount of worsening was greater at 7 years (1.89 units; P <.001) than at 2 years (0.64 units; P =.071). In the Associative Analysis, eyes with 100% of visits with intraocular pressure less than 18 mm Hg over 6 years had mean changes from baseline in visual field defect score close to zero during follow-up, whereas eyes with less than 50% of visits with intraocular pressure less than 18 mm Hg had an estimated worsening over follow-up of 0.63 units of visual field defect score (P =.083). This amount of worsening was greater at 7 years (1.93 units; P <.001) than at 2 years (0.25 units; P =.572). In both analyses low intraocular pressure is associated with reduced

  7. Delivery of Intraocular Triamcinolone Acetonide in the Treatment of Macular Edema

    Directory of Open Access Journals (Sweden)

    Brent Siesky

    2012-03-01

    Full Text Available Macular edema (ME is one of the eventual outcomes of various intraocular and systemic pathologies. The pathogenesis for ME is not yet entirely understood; however, some of the common risk factors for its development have been identified. While this investigation will not discuss the numerous etiologies of ME in detail, it appraises the two most widely studied delivery modalities of intraocular corticosteroids in the treatment of ME—intravitreal injection (IVI and sub-Tenon’s infusion (STI. A thorough review of the medical literature was conducted to identify the efficacy and safety of IVI and STI, specifically for the administration of triamcinolone acetonide (TA, in the setting of ME in an attempt to elucidate a preferred steroid delivery modality for treatment of ME.

  8. Effect of intravenous metoclopramide on intraocular pressure: A prospective, randomized, double-blind, placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Sudheera K

    2008-01-01

    Full Text Available Background: Prevention of rise in intraocular pressure (IOP is essential in patients undergoing surgery for perforated eye injuries. Metoclopramide, a prokinetic agent, is commonly used to hasten gastric emptying in emergency surgeries. Aim: To study the change in IOP after intravenous metoclopramide and to study the influence of metoclopramide on change in IOP after succinylcholine and tracheal intubation. Settings and Design: A randomized, double-blind, placebo-controlled study of 60 patients undergoing non-ophthalmic elective surgery. Materials and Methods: Sixty American Society of Anesthesiologists (ASA I adult patients were randomly assigned to receive normal saline (Group C or metoclopramide 10 mg (Group M 30 min before the induction of anesthesia. Thiopentone was used for induction and succinylcholine for tracheal intubation. Intraocular pressure was measured in both the eyes pre and post drug treatment and succinylcholine and tracheal intubation using Perkins applanation tonometer. Statistical Analysis: Student′s t-test and repeated measures ANOVA were used. A P value < 0.05 was considered as significant. Results: Intraocular pressure was consistently lower in Group M than in Group C after the test drug, though the difference was not statistically significant. Intraocular pressure decreased significantly after administration of thiopentone and increased significantly in Groups C and M after tracheal intubation ( P < 0.01. Intraocular pressure was comparable between the groups at all the times. Conclusions: Metoclopramide does not cause a clinically significant change in IOP nor does it influence the changes in IOP during anesthesia and tracheal intubation. Metoclopramide shows a trend towards decrease in IOP, though clinically insignificant. Therefore metoclopramide can be used to promote gastric emptying in patients with perforated eye injury.

  9. Neodymium:YAG laser cutting of intraocular lens haptics.

    Science.gov (United States)

    Gorn, R A; Steinert, R F

    1985-11-01

    Neodymium:YAG laser cutting of polymethylmethacrylate and polypropylene anterior chamber and posterior chamber intraocular lens haptics was studied in terms of ease of transection and physical structure of the cut areas as seen by scanning electron microscopy. A marked difference was discovered, with the polymethylmethacrylate cutting easily along transverse planes, whereas the polypropylene resisted cutting along longitudinal fibers. Clinical guidelines are presented.

  10. Primary intraocular chondrosarcoma in a dog

    Directory of Open Access Journals (Sweden)

    E. Perlmann

    2013-12-01

    Full Text Available A five-year-old male Cocker Spaniel was presented for evaluation of the right eye due to discomfort, abundant purulent discharge and progressive enlargement of the eyeball. The owner revealed that the right eye has appeared to be inflamed and smaller then the left eye for years. Ophthalmic examination revealed corneal perforation, buphthalmia and conjuctival hyperemia. Enucleating was performed due to signs of endophthalmitis and ocular discomfort. Histopathology revealed a multilobulated proliferation of chondrocytes producing hyaline cartilage with occasional pleomorphism and binucleate cells. A diagnosis of primary intraocular chondrosarcoma was done.

  11. Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Ya-wen Guo

    2014-01-01

    Full Text Available Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. Results. The hydrophilic acrylic IOLs showed significantly lower straylight values than those of the hydrophobic acrylic IOLs in dilated pupils at 1 week and 1 month after surgery (P0.05. Moreover, no significant difference was found in straylight between natural and dilated pupils in each group at 1 week and 1 month postoperatively (P>0.05. Conclusions. Although the hydrophobic acrylic IOL induced more intraocular straylight, straylight differences among the 3 IOLs were minimal. Pupil size showed no effect on intraocular straylight; the intraocular straylight was stable 1 week after surgery.

  12. Intraocular 6-hydroxydopamine prevents the persistent estrus induced by continuous light.

    Science.gov (United States)

    Shimizu, K; Hokano, M

    1985-01-15

    Following the intraocular injection of 6-hydroxydopamine, which can destroy the retinal dopaminergic neurons, female rats showed a normal estrous cycle in LD 12:12 but not a persistent estrus in continuous light.

  13. Effect of hemodialysis on intraocular lens power calculation.

    Science.gov (United States)

    Çalışkan, Sinan; Çelikay, Osman; Biçer, Tolga; Aylı, Mehmet Deniz; Gürdal, Canan

    2016-01-01

    To evaluate changes in ocular biometric parameters after hemodialysis (HD) in patients with end-stage renal disease (ESRD). Forty eyes of 40 patients undergoing HD were included in this cross-sectional study. Keratometry (K) readings, white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter, lens thickness (LT), axial length (AL), and intraocular lens (IOL) power calculation were measured with Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland) before and after hemodialysis. Intraocular pressure (IOP) was measured with a non-contact tonometer (Tonopachy NT-530P, Nidek Co., LTD, Tokyo, Japan). Main outcomes were changes in biometric parameters after HD. Reliability of the measurements (intraclass correlation coefficients (ICCs)) and the effect size (Cohen's d) were also calculated. Mean difference in AL before and after HD was -0.041 ± 0.022 mm with ICCs > 0.90 (p  0.90 (p = 0.041 and Cohen's d = 0.20). Hemodialysis had no significant effect on K readings, WTW distance, CCT, ACD, LT, or IOP. Axial length and pupil diameter increase after HD with small effect size, while HD does not significantly affect IOL power calculations.

  14. Associação entre dois diferentes tipos de estrangulamento com a variação da pressão intraocular em atletas de jiu-jitsu Association between two different types of strangling and intraocular pressure variation in jiu-jitsu athletes

    Directory of Open Access Journals (Sweden)

    Marinho Jorge Scarpi

    2009-06-01

    Full Text Available OBJETIVO: Verificar a associação entre dois diferentes tipos de estrangulamento com a variação da pressão intraocular em atletas de jiu-jitsu. MÉTODO: Estudo observacional em grupo de 9 atletas de jiu-jitsu, com mínimo 6 meses de treinamento, sexo masculino, idades entre 20 e 30 anos, sem presença de lesões físicas e do bulbo ocular. Buscou-se associação entre a variação da pressão intraocular e os estrangulamentos Frontal da Guarda (E1 e Frontal da Montada (E2. A pressão intraocular foi determinada com o tonômetro de Perkins, inicialmente sem que o atleta tivesse realizado atividade física nas 24 horas antecedentes e após cada golpe. Realizou-se medidas da pressão intraocular por 12 minutos, uma a cada 3 minutos de recuperação (R1; R2; R3; R4, com o indivíduo deitado. Como procedimento estatístico foi empregado o teste ANOVA e o pós-teste de Bonferroni. RESULTADOS: Ocorreu redução significativa da pressão intraocular em ambos os olhos durante a situação E2 comparada a E1 em todos os momentos da aferição de recuperação: R1 (OD: 8,22 ± 1,39 vs.11,33 ± 2,00 / OE: 8,55 ± 1,23 vs. 11,88 ± 1,90, R2 (OD: 8,44 ± 1,87 vs.10,22 ± 2,53 / OE: 9,00 ± 1,80 vs. 10,44 ± 2,35, R3 (OD: 8,44 ± 1,74 vs.9,78 ± 2,54 / OE: 8,55 + 1,42 vs. 10,33 ± 1,93 todos com pPURPOSE: To verify the association between two different types of strangling with intraocular pressure variation in jiu-jitsu athletes. METHODS: An observational study was performed on 9 athletes of jiu-jitsu, with at least 6 month of training, male, aged 20 to 30 years, without any physical and eyeball lesions. Associations between intraocular pressure and Cross Choke from the guard strangling (E1, and E2 - Cross Choke from mount strangling were gotten. Intraocular pressure was determined by using Perkins tonometer, at first in the absence of physical exercise over the last 24 hours and after each strangling. Then it was carried out the intraocular pressure

  15. Intermediate-term and long-term outcome of piggyback drainage: connecting glaucoma drainage device to a device in-situ for improved intraocular pressure control.

    Science.gov (United States)

    Dervan, Edward; Lee, Edward; Giubilato, Antonio; Khanam, Tina; Maghsoudlou, Panayiotis; Morgan, William H

    2017-11-01

    This study provides results of a treatment option for patients with failed primary glaucoma drainage device. The study aimed to describe and evaluate the long-term intraocular pressure control and complications of a new technique joining a second glaucoma drainage device directly to an existing glaucoma drainage device termed 'piggyback drainage'. This is a retrospective, interventional cohort study. Eighteen eyes of 17 patients who underwent piggyback drainage between 2004 and 2013 inclusive have been studied. All patients had prior glaucoma drainage device with uncontrolled intraocular pressure. The piggyback technique involved suturing a Baerveldt (250 or 350 mm) or Molteno3 glaucoma drainage device to an unused scleral quadrant and connecting the silicone tube to the primary plate bleb. Failure of intraocular pressure control defined as an intraocular pressure greater than 21 mmHg on maximal therapy on two separate occasions or further intervention to control intraocular pressure. The intraocular pressure was controlled in seven eyes (39%) at last follow-up with a mean follow-up time of 74.2 months. The mean preoperative intraocular pressure was 27.1 mmHg (95% confidence interval 23.8-30.3) compared with 18.4 mmHg (95% confidence interval 13.9-22.8) at last follow-up. The mean time to failure was 57.1 months (95% confidence interval 32.2-82), and the mean time to further surgery was 72.3 months (95% confidence interval 49.9-94.7). Lower preoperative intraocular pressure was associated with longer duration of intraocular pressure control (P = 0.048). If the intraocular pressure was controlled over 2 years, it continued to be controlled over the long term. Two eyes (11%) experienced corneal decompensation. Piggyback drainage represents a viable surgical alternative for the treatment of patients with severe glaucoma with failing primary glaucoma drainage device, particularly in those at high risk of corneal decompensation. © 2017 Royal Australian and New Zealand

  16. Human Intraocular Filariasis Caused by Dirofilaria sp. Nematode, Brazil

    Science.gov (United States)

    Diniz, Daniel G.; Dantas-Torres, Filipe; Casiraghi, Maurizio; de Almeida, Izabela N.F.; de Almeida, Luciana N.F.; Nascimento dos Santos, Jeannie; Furtado, Adriano Penha; Sobrinho, Edmundo F. de Almeida; Bain, Odile

    2011-01-01

    A case of human intraocular dirofilariasis is reported from northern Brazil. The nematode was morphologically and phylogenetically related to Dirofilaria immitis but distinct from reference sequences, including those of D. immitis infesting dogs in the same area. A zoonotic Dirofilaria species infesting wild mammals in Brazil and its implications are discussed. PMID:21529396

  17. Branch retinal artery occlusion post-penetrating globe injury with intraocular foreign body.

    Science.gov (United States)

    Nagpal, Manish; Chaudhary, Pranita; Jain, Ashish

    2018-01-01

    Intraocular foreign body (IOFB) in cases of penetrating eye injury accounts for an important indication of vitreoretinal intervention following ocular trauma. Vascular occlusion as a complication of IOFB is rare. Here we present a case of a 34-year-old male with post-traumatic cataract and an intraocular metallic foreign body (IOFB) lodged in the superficial layers of the retina inferotemporal to the disc, causing an inferotemporal branch retinal artery occlusion. The case was managed by lensectomy with pars plana vitrectomy and IOFB removal followed by a second procedure of secondary IOL implantation. Final best-corrected visual acuity improved to 6/24. This case highlights an unusual sequelae following penetrating ocular trauma.

  18. Branch retinal artery occlusion post-penetrating globe injury with intraocular foreign body

    Directory of Open Access Journals (Sweden)

    Manish Nagpal

    2018-01-01

    Full Text Available Intraocular foreign body (IOFB in cases of penetrating eye injury accounts for an important indication of vitreoretinal intervention following ocular trauma. Vascular occlusion as a complication of IOFB is rare. Here we present a case of a 34-year-old male with post-traumatic cataract and an intraocular metallic foreign body (IOFB lodged in the superficial layers of the retina inferotemporal to the disc, causing an inferotemporal branch retinal artery occlusion. The case was managed by lensectomy with pars plana vitrectomy and IOFB removal followed by a second procedure of secondary IOL implantation. Final best-corrected visual acuity improved to 6/24. This case highlights an unusual sequelae following penetrating ocular trauma.

  19. A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery

    Directory of Open Access Journals (Sweden)

    Bikramjit Das

    2016-02-01

    Full Text Available BACKGROUND: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. METHODS: Ninety adult patients were randomly assigned to study group or control group. Study group (n = 45 - Airtraq laryngoscope was used for laryngoscopy. Control group (n = 45 - conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngoscopy was done as per group protocol. Intraocular pressure and haemodynamic parameters were recorded just before insertion of the device and subsequently three times at an interval of one minute after insertion of the device. RESULTS: Patient characteristics, baseline haemodynamic parameters and baseline intraocular pressure were comparable in the two groups. Following insertion of the endotracheal tube with Macintosh laryngoscope, there was statistically significant rise in heart rate and intraocular pressure compared to Airtraq group. There was no significant change in MAP. Eight patients in Macintosh group had tongue-lip-dental trauma during intubation, while only 2 patients received upper airway trauma in Airtraq group. CONCLUSION: We conclude that Airtraq laryngoscope in comparison to Macintosh laryngoscope results in significantly fewer rises in intraocular pressure and clinically less marked increase in haemodynamic response to laryngoscopy and intubation.

  20. Role of light and the circadian clock in the rhythmic oscillation of intraocular pressure: Studies in VPAC2 receptor and PACAP deficient mice.

    Science.gov (United States)

    Fahrenkrug, Jan; Georg, Birgitte; Hannibal, Jens; Jørgensen, Henrik Løvendahl

    2018-04-01

    The intraocular pressure of mice displays a daily rhythmicity being highest during the dark period. The present study was performed to elucidate the role of the circadian clock and light in the diurnal and the circadian variations in intraocular pressure in mice, by using animals with disrupted clock function (VPAC2 receptor knockout mice) or impaired light information to the clock (PACAP knockout mice). In wildtype mice, intraocular pressure measured under light/dark conditions showed a statistically significant 24 h sinusoidal rhythm with nadir during the light phase and peak during the dark phase. After transfer of the wildtype mice into constant darkness, the intraocular pressure increased, but the rhythmic changes in intraocular pressure continued with a pattern identical to that obtained during the light/dark cycle. The intraocular pressure in VPAC2 receptor deficient mice during light/dark conditions also showed a sinusoidal pattern with significant changes as a function of a 24 h cycle. However, transfer of the VPAC2 receptor knockout mice into constant darkness completely abolished the rhythmic changes in intraocular pressure. The intraocular pressure in PACAP deficient mice oscillated significantly during both 24 h light and darkness and during constant darkness. During LD conditions, the amplitude of PACAP deficient was significantly lower compared to wildtype mice, resulting in higher daytime and lower nighttime values. In conclusion, by studying the VPAC2 receptor knockout mouse which lacks circadian control and the PACAP knockout mouse which displays impaired light signaling, we provided evidence that the daily intraocular pressure rhythms are primarily generated by the circadian master clock and to a lesser extent by environmental light and darkness. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Deformed quantum double realization of the toric code and beyond

    Science.gov (United States)

    Padmanabhan, Pramod; Ibieta-Jimenez, Juan Pablo; Bernabe Ferreira, Miguel Jorge; Teotonio-Sobrinho, Paulo

    2016-09-01

    Quantum double models, such as the toric code, can be constructed from transfer matrices of lattice gauge theories with discrete gauge groups and parametrized by the center of the gauge group algebra and its dual. For general choices of these parameters the transfer matrix contains operators acting on links which can also be thought of as perturbations to the quantum double model driving it out of its topological phase and destroying the exact solvability of the quantum double model. We modify these transfer matrices with perturbations and extract exactly solvable models which remain in a quantum phase, thus nullifying the effect of the perturbation. The algebra of the modified vertex and plaquette operators now obey a deformed version of the quantum double algebra. The Abelian cases are shown to be in the quantum double phase whereas the non-Abelian phases are shown to be in a modified phase of the corresponding quantum double phase. These are illustrated with the groups Zn and S3. The quantum phases are determined by studying the excitations of these systems namely their fusion rules and the statistics. We then go further to construct a transfer matrix which contains the other Z2 phase namely the double semion phase. More generally for other discrete groups these transfer matrices contain the twisted quantum double models. These transfer matrices can be thought of as being obtained by introducing extra parameters into the transfer matrix of lattice gauge theories. These parameters are central elements belonging to the tensor products of the algebra and its dual and are associated to vertices and volumes of the three dimensional lattice. As in the case of the lattice gauge theories we construct the operators creating the excitations in this case and study their braiding and fusion properties.

  2. Computational modeling of intraocular gas dynamics

    International Nuclear Information System (INIS)

    Noohi, P; Abdekhodaie, M J; Cheng, Y L

    2015-01-01

    The purpose of this study was to develop a computational model to simulate the dynamics of intraocular gas behavior in pneumatic retinopexy (PR) procedure. The presented model predicted intraocular gas volume at any time and determined the tolerance angle within which a patient can maneuver and still gas completely covers the tear(s). Computational fluid dynamics calculations were conducted to describe PR procedure. The geometrical model was constructed based on the rabbit and human eye dimensions. SF_6 in the form of pure and diluted with air was considered as the injected gas. The presented results indicated that the composition of the injected gas affected the gas absorption rate and gas volume. After injection of pure SF_6, the bubble expanded to 2.3 times of its initial volume during the first 23 h, but when diluted SF_6 was used, no significant expansion was observed. Also, head positioning for the treatment of retinal tear influenced the rate of gas absorption. Moreover, the determined tolerance angle depended on the bubble and tear size. More bubble expansion and smaller retinal tear caused greater tolerance angle. For example, after 23 h, for the tear size of 2 mm the tolerance angle of using pure SF_6 is 1.4 times more than that of using diluted SF_6 with 80% air. Composition of the injected gas and conditions of the tear in PR may dramatically affect the gas absorption rate and gas volume. Quantifying these effects helps to predict the tolerance angle and improve treatment efficiency. (paper)

  3. Raised intraocular pressure and recurrence of retinal detachment as complications of external retinal detachment surgery

    International Nuclear Information System (INIS)

    Jawwad, M.; Khan, B.; Shah, M.A.; Qayyum, I.; Aftab, M.; Qayyum, I.

    2015-01-01

    Patients with Rhegmatogenous retinal detachment may develop raised intraocular pressure and recurrence of retinal detachment when they undergo external retinal detachment surgery. The present study was conducted to determine the postoperative rise in intraocular pressure (IOP) and recurrence of retinal detachment. Methods: The present descriptive study was conducted at Eye department of Lady Reading Hospital, Peshawar on 25 patients of both genders from August 2012 to July 2014. Results: Of the 25 patients, 18 (72%) developed raised IOP in the immediate postoperative period; this figure decreased to 12 (48%) at one week. Following medical or surgical intervention in these 12 cases, there was only 1 (4%) case with mildly raised IOP at two weeks postoperative. Five (20%) cases developed recurrent retinal detachment which later resolved with treatment. There were no significant differences by age or gender. Conclusion: External Retinal Detachment Surgery raised intraocular pressure postoperatively and caused recurrence of retinal detachment. These complications were treated medically and surgically with resolution within two weeks. (author)

  4. Optimizing outcomes with multifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gitansha Shreyas Sachdev

    2017-01-01

    Full Text Available Modern day cataract surgery is evolving from a visual restorative to a refractive procedure. The advent of multifocal intraocular lenses (MFIOLs allows greater spectacle independence and increased quality of life postoperatively. Since the inception in 1980s, MFIOLs have undergone various technical advancements including trifocal and extended depth of vision implants more recently. A thorough preoperative workup including the patients' visual needs and inherent ocular anatomy allows us to achieve superior outcomes. This review offers a comprehensive overview of the various types of MFIOLs and principles of optimizing outcomes through a comprehensive preoperative screening and management of postoperative complications.

  5. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  6. In vivo longitudinal chromatic aberration of pseudophakic eyes.

    Science.gov (United States)

    Siedlecki, Damian; Jóźwik, Agnieszka; Zając, Marek; Hill-Bator, Aneta; Turno-Kręcicka, Anna

    2014-02-01

    To present the results of longitudinal chromatic aberration measurements on two groups of pseudophakic eyes in comparison to healthy eyes. The longitudinal chromatic aberration of the eye, defined as chromatic difference of refraction with disabled accommodation, was measured with the use of a visual refractometer with a custom-designed target illuminator consisting of a narrow-band RGB diode (blue λb = 470 ± 15 nm; green λg = 525 ± 18 nm; red λr = 660 ± 10 nm). The measurements were performed on nine eyes implanted with AcrySof IQ SN60WF, 14 eyes implanted with AcrySof SA60AT, and 10 phakic eyes under cycloplegia. The mean values of the longitudinal chromatic aberration between 470 and 660 nm for the control group was 1.12 ± 0.14 D. For SA60AT group, it was 1.45 ± 0.42 D whereas for SN60WF it was 1.17 ± 0.52 D. The statistical test showed significant difference between SA60AT and the control group (p chromatic aberration in vivo can be easily and reliably estimated with an adapted visual refractometer. The two groups of pseudophakic eyes measured in this study showed different values of chromatic aberration. Its magnitude for SA60AT group was significantly larger than for the control group whereas for SN60WF the difference was not significant. The optical material used for intraocular lens design may have significant influence on the magnitude of the chromatic aberration of the pseudophakic eye, and therefore on its optical and visual performance in polychromatic light.

  7. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Vrijman, V.; El-Saady, R.; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2014-01-01

    PURPOSE: To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). METHODS: This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric

  8. Measurements of Mode Converted Ion Cyclotron Wave with Phase Contrast Imaging in Alcator C-Mod and Comparisons with Synthetic PCI Simulations in TORIC

    International Nuclear Information System (INIS)

    Tsujii, N.; Porkolab, M.; Edlund, E. M.; Lin, L.; Lin, Y.; Wright, J. C.; Wukitch, S. J.

    2009-01-01

    Mode converted ion cyclotron wave (ICW) has been observed with phase contrast imaging (PCI) in D- 3 He plasmas in Alcator C-Mod. The measurements were carried out with the optical heterodyne technique using acousto-optic modulators which modulate the CO2 laser beam intensity near the ion cyclotron frequency. With recently improved calibration of the PCI system using a calibrated sound wave source, the measurements have been compared with the full-wave code TORIC, as interpreted by a synthetic diagnostic. Because of the line-integrated nature of the PCI signal, the predictions are sensitive to the exact wave field pattern. The simulations are found to be in qualitative agreement with the measurements.

  9. Comparação de resposta da pressão intraocular frente a duas diferentes intensidades e volumes do treinamento resistido

    Directory of Open Access Journals (Sweden)

    Marcelo Conte

    2014-01-01

    Full Text Available Objetivo: Verificar a influência de duas diferentes intensidades e volumes de treinamento resistido na pressão intraocular. Método: Dezenove boxeadores (13 homens e 6 mulheres; idade média de 22 ± 3 anos foram randomicamente submetidos a duas diferentes sessões de exercícios resistidos: resistência muscular com 3 séries de 15 repetições máximas e hipertrofia muscular com 4 séries de 8RM. A pressão intraocular foi obtida com Tonometro de Perkins antes, durante e após as sessões de exercício resistido. Os dados foram expressos em média e desvio padrão. Foi realizada análise de variância (ANOVA com medidas repetidas e pós teste de Tukey. Resultados: Foi observada redução da pressão intraocular durante as sessões de treinamento resistido. Contudo, a sessão de exercício para resistência muscular promoveu uma redução significativa da pressão intraocular comparada a de hipertrofia muscular. Ao final da sessão de resistência muscular a pressão intraocular retornou aos valores prévios ao exercício, por outro lado na sessão de hipertrofia muscular a pressão intraocular após o término dos exercícios apresentou-se acima dos valores iniciais. Conclusão: O treinamento resistido pode influenciar os valores da pressão intraocular, especificamente 3 séries de 15 repetições com 60% de 1RM promoveu respostas hipotensivas mais expressivas na pressão intraocular do que 3 séries de 8 repetições com 80% de 1RM. Esses achados podem contribuir para prescrição de exercício resistido para pessoas com fatores de risco para o glaucoma.

  10. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    Science.gov (United States)

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  11. Personalización de las constantes en las fórmulas de cálculo de la lente intraocular Personalization of constants in the intraocular lens calculation formulas

    Directory of Open Access Journals (Sweden)

    Anneé Miranda Carracedo

    2012-12-01

    Full Text Available Objetivo: personalizar las constantes A, factor cirujano y profundidad de la cámara anterior para las fórmulas de cálculo de la lente intraocular en la cirugía de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" de mayo de 2007 a enero de 2011. Métodos: se realizó un estudio descriptivo retrospectivo donde se estudiaron las constantes A, factor cirujano y profundidad de la cámara anterior. También se evaluó la longitud axial preoperatoria por IOL Master, la mejor agudeza visual sin corrección, el componente esférico esperado, el componente esférico obtenido y los resultados refractivos. Resultados: las constantes optimizadas por interferometría de coherencia parcial son diferentes a las propuestas por los fabricantes de las lentes intraoculares. Estas constantes personalizadas para cada cirujano no mostraron diferencias significativas. Las constantes optimizadas según las longitudes axiales, tienen diferencias significativas en los 3 grupos de estudio. La diferencia entre la lente intraocular implantada y la propuesta con las nuevas constantes resultó menor de 1 D de error en 83,1 % de los pacientes. El 75,4 % quedó bien corregido en relación con la diferencia entre la refracción esperada y la obtenida. Conclusiones: las constantes optimizadas por interferometría de coherencia parcial resultan más elevadas que las propuestas por el fabricante. La optimización de estas en el cálculo de la lente permite, de acuerdo a las características individuales de cada ojo (longitud axial, usar la fórmula adecuada e incrementa la predictibilidad de los resultados refractivos posoperatorios.Objective: to personalize the A, surgeon factor and anterior chamber depth constants for intraocular lens calculation formulas in the cataract surgery at the “Ramón Pando Ferrer” Cuban Ophthalmological Institute from May 2007 to January 2011. Method: a retrospective and descriptive study was made to study the A constant

  12. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J.; Mourits, Maarten P.; Lapid-Gortzak, Ruth

    2014-01-01

    To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312

  13. Clinical observation of four-fixable intraocular lens suspensory

    Directory of Open Access Journals (Sweden)

    Yu-Ming Teng

    2015-06-01

    Full Text Available AIM: To discuss the four-fixable intraocular lens(IOLsuspensory in the absence of capsular intraocular lens implantation, suspensory ligament rupture caused by congenital dislocation of the lens, traumatic cataract and posterior capsular rupture without capsular support, which need to line hanging IOL for intraoperative clinical observation.METHODS: The 31 cases(32 eyeswho were accepted the four-fixable IOL suspensory from May 2012 to May 2014 in our hospital were retrospectively analyzed. The postoperative visual acuity, corneal astigmatism, intraoperative and postoperative complications were comprehensively analyzed.RESULTS: Patients were followed up 6mo~1a, corrected visual acuity >0.5(12 eyes, 38%, 0.1~0.5(18 eyes, 56%, and CONCLUSION: It is designed to support non-capsular IOL implantation and design, and the concept of changing the past presence of suspended dislocated IOL implantation surgery, positional deviation and, sutures and other complications split the incidence is greatly reduced. It is consistent with the physiological characteristics of the human eye, and it is the IOL surgical sling best stability, intraoperative and postoperative complications, the best visual acuity and corneal astigmatism minimal surgical approachat least, and the four-point suspension suture fixation of IOL is designed to obtain a practical transformation of Chinese patent.

  14. Intraocular lenses and clinical treatment in paediatric cataract

    Directory of Open Access Journals (Sweden)

    Camila Ribeiro Koch Pena

    2015-06-01

    Full Text Available Pediatric cataract is the most common treatable cause of blindness in children. Prevalence, etiology and morphology vary with the socioeconomic development. The treatment goal is to reduce amblyopia, being difficult management especially in unilateral cases. The decision on aphakia or primary intraocular lens should be individualized as well as correction with contact lens or spectacles. The intraocular lens single-piece hydrophobic acrylic are the most implanted in children and the preferably is in the capsular bag. The Sanders-Retzlaff-Kraff theoretic (SRK/T stressing that is described as more predictable, following Holladay I and SRK II and the recommendation is to under correction +6.0 or +8.0 dioptrias expecting the growth of the eye. The posterior capsule opacity is the most frequent complication and varies with the material choice of the lens. Glaucoma is the most serious postoperative complication and depends on the timing of the surgery, primary lens implantation and time of post surgical follow-up. The adherence to occlusion therapy with patching is critical to the visual prognosis and is determined by the child’s age and laterality of the cataract. There was significant improvement in the surgery and in IOLs, however the final visual prognosis is still not desirable.

  15. Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes

    NARCIS (Netherlands)

    Nuijts, Rudy M. M. A.; Jonker, Soraya M. R.; Kaufer, Robert A.; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas

    2016-01-01

    To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8

  16. Cuerpo extraño intraocular en el segmento posterior Intraocular foreign bodies in the posterior segment

    Directory of Open Access Journals (Sweden)

    Diley Pérez García

    2012-01-01

    Full Text Available El trauma causado por cuerpo extraño intraocular es una de las principales causas de pérdida visual severa. Técnicamente es un trauma penetrante con permanencia del agente agresor dentro del globo ocular. Constituye una verdadera emergencia oftalmológica, pues puede ocasionar ceguera aún cuando se realiza un diagnóstico y tratamiento adecuados. Se realizó esta revisión para proponer un algoritmo de trabajo con el propósito de maximizar la recuperación anatómica y funcional después de una lesión de este tipo. La conducta a seguir ante este paciente requiere un tratamiento guiado por la apreciación del mecanismo del daño, naturaleza, localización y tamaño del cuerpo extraño; los conocimientos y la disposición del equipamiento necesario para el tratamiento quirúrgico y los cuidados posoperatorios. Existe controversia en cuanto al momento de extracción del cuerpo extraño; sin embargo, se debe realizar una conducta. La profilaxis de la endoftalmitis con antibióticos sistémicos es recomendada y la intravítrea de antibiótico debe ser considerada en los pacientes de alto riesgo. Se debe realizar el diagnóstico precoz o detección posoperatoria temprana de complicaciones como el desprendimiento de retina, endoftalmitis y la proliferación vítreorretiniana, que se han asociado con un pobre pronóstico visual.Intraocular foreign bodies are a major cause for severe visual loss. By technical definition, it consists of a form of penetrating ocular trauma, characterized by the persistence of the traumatic agent inside the eye, and is considered an ophthalmic emergency, since it may cause blindness even if good diagnosis and treatment are followed. This review was made to submit a management algorithm that can maximize the anatomical and functional outcomes after this type of injury. The management of these patients requires taking into account the mechanism of eye injury, the nature, the location and the size of the foreign body

  17. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-06-01

    Full Text Available Mun Yueh Faria,1 Nuno Ferreira,2 Eliana Neto,1 1Vitreo Retinal Department, 2Ophthalmology Department, Santa Maria Hospital, Lisbon, Portugal Objective: To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL in ectopia lentis in Marfan syndrome (MFS. Design: Retrospective study. Methods: Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA, and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years. Results: The average follow-up period was 6.66 months (range: 4–16 months. Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was –0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg and 16 mmHg (range: 12–18 mmHg, respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm, as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion: Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that

  18. The Effect of Altitude on Intraocular Pressure in Vitrectomized Eyes with Sulfur Hexafluoride Tamponade by the Friedenwald Method: Rabbit Animal Model

    Directory of Open Access Journals (Sweden)

    Jans Fromow-Guerra

    2016-01-01

    Full Text Available The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF6, 100% saline solution, and 100% room air. A sixth eye was injected with 0.35 cc of undiluted SF6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit’s scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m. There were significant differences in intraocular pressure on the rabbit eyes filled with SF6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity.

  19. Pharmacokinetics and efficacy of intraocular flurbiprofen.

    Science.gov (United States)

    Blazaki, S; Tsika, C; Tzatzarakis, M; Naoumidi, E; Tsatsakis, A; Tsatsanis, C; Tsilimbaris, Miltiadis K

    2017-12-01

    Intravitreal delivery of non-steroidal anti-inflammatory drugs could be an effective way to treat macular edema caused by posterior segment inflammation. In this study, we evaluated the intravitreal bioavailability and anti-inflammatory efficacy of flurbiprofen in rabbit eyes. For pharmacokinetics, 0.1 ml of 7.66 mg/ml flurbiprofen solution was injected intravitreally and vitreous drug levels were analyzed at specific time points using LC-MS technique. For efficacy, 100 ng lipopolysaccharide of E.coli was injected intravitreally in rabbits to induce inflammation. The animals were separated in three groups and received intraocular flurbiprofen, dexamethasone and PBS to serve as control. Complete ocular examination and total cell count in aqueous fluid were determined to evaluate the extent of inflammation. Eyes were then enucleated for histopathology analysis. The efficacy in the uveitis model was determined by clinical signs of inflammation, total leukocyte count and histology findings. No adverse events were observed during pharmacokinetic assessment. No signs of inflammation, hemorrhage or retina detachment were detected. The recovery of flurbiprofen from vitreous samples was 92.6%. The half-life of flurbiprofen was estimated to be 1.92 h with an elimination constant rate (K) of 0.36. Treatment with intraocular injections of flurbiprofen and dexamethasone significantly reduced total leukocyte count in a manner comparable to dexamethasone [reduction of 96.84% (p flurbiprofen injection compared to control eyes. Flurbiprofen is effective in suppressing inflammation in this experimental uveitis model. In our experimental setting, intravitreal flurbiprofen seem to have a therapeutic result comparable to dexamethasone. However, the half-life of the drug remains short, necessitating further research to prolong its presence in the vitreous cavity.

  20. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  1. Review and update of intraocular therapy in noninfectious uveitis.

    Science.gov (United States)

    Sallam, Ahmed; Taylor, Simon R J; Lightman, Sue

    2011-11-01

    To review new clinically relevant data regarding the intraocular treatment of noninfectious uveitis. Triamcinolone acetonide, the most commonly used intravitreal corticosteroid for treatment of uveitis and uveitic macular oedema has a limited duration of action and is associated with a high risk of corticosteroid-induced intraocular pressure (IOP) rise and cataract. Recent advances have led to the development of sustained-release corticosteroid devices using different corticosteroids such as dexamethasone and fluocinolone acetonide. Treatment options for patients who have previously exhibited corticosteroid hypertensive response have also expanded through the use of new noncorticosteroid intravitreal therapeutics such as methotrexate and antivascular endothelial growth factor (anti-VEGF) agents. Ozurdex dexamethasone implant appears to have a better safety profile, and a slightly long-lasting effect than triamcinolone acetonide. The Retisert implant allows the release of corticosteroids at a constant rate for 2.5 years, but it requires surgical placement and its use is associated with a very high risk of cataract and requirement for IOP-lowering surgery. For patients who are steroid responders, methotrexate may offer a better alternative to corticosteroid treatment than anti-VEGF agents, but controlled trials are required to confirm this.

  2. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  3. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad; Ouda, Mahmoud H.; Marnat, Loic; Shamim, Atif; Salama, Khaled N.

    2013-01-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  4. Bilateral spontaneous subluxation of scleral-fixated intraocular lenses.

    Science.gov (United States)

    Assia, Ehud I; Nemet, Arie; Sachs, Dani

    2002-12-01

    Two young men with primary ectopic lenses had intracapsular cataract extraction and scleral fixation of posterior chamber intraocular lenses (PC IOLs) using 10-0 polypropylene sutures tied to the IOL eyelets. Three to 9 years after implantation, spontaneous IOL vertical subluxation occurred in all 4 eyes (5 IOL loops), probably because of suture breakage. Late subluxation of a sutured IOL may occur several years after implantation. Double fixation and thicker sutures should be considered, especially in young patients.

  5. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2012-06-01

    Full Text Available PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively. The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group. CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

  6. Intraocular Lens Use in an Astronaut During Long Duration Spaceflight.

    Science.gov (United States)

    Mader, Thomas H; Gibson, C Robert; Schmid, Josef F; Lipsky, William; Sargsyan, Ashot E; Garcia, Kathleen; Williams, Jeffrey N

    2018-01-01

    The purpose of this paper is to report the first use of an intraocular lens (IOL) in an astronaut during long duration spaceflight (LDSF). An astronaut developed a unilateral cataract and underwent phacoemulsification with insertion of an acrylic IOL. Approximately 15 mo later he flew on a Soyuz spacecraft to the International Space Station (ISS), where he successfully completed a 6-mo mission. Ocular examination, including ultrasound (US), was performed before, during, and after his mission and he was questioned regarding visual changes during each portion of his flight. We documented no change in IOL position during his space mission. This astronaut reported excellent and stable vision during liftoff, entry into microgravity (MG), 6 mo on the ISS, descent, and landing. Our results suggest that modern IOLs are stable, effective, and well tolerated during LDSF.Mader TH, Gibson CR, Schmid JF, Lipsky W, Sargsyan AE, Garcia K, Williams JN. Intraocular lens use in an astronaut during long duration spaceflight. Aerosp Med Hum Perform. 2018; 89(1):63-65.

  7. Common Genetic Determinants of Intraocular Pressure and Primary Open-Angle Glaucoma

    NARCIS (Netherlands)

    van Koolwijk, Leonieke M. E.; Ramdas, Wishal D.; Ikram, M. Kamran; Jansonius, Nomdo M.; Pasutto, Francesca; Hysi, Pirro G.; Macgregor, Stuart; Janssen, Sarah F.; Hewitt, Alex W.; Viswanathan, Ananth C.; ten Brink, Jacoline B.; Hosseini, S. Mohsen; Amin, Najaf; Despriet, Dominiek D. G.; Willemse-Assink, Jacqueline J. M.; Kramer, Rogier; Rivadeneira, Fernando; Struchalin, Maksim; Aulchenko, Yurii S.; Weisschuh, Nicole; Zenkel, Matthias; Mardin, Christian Y.; Gramer, Eugen; Welge-Luessen, Ulrich; Montgomery, Grant W.; Carbonaro, Francis; Young, Terri L.; Bellenguez, Celine; McGuffin, Peter; Foster, Paul J.; Topouzis, Fotis; Mitchell, Paul; Wang, Jie Jin; Wong, Tien Y.; Czudowska, Monika A.; Hofman, Albert; Uitterlinden, Andre G.; Wolfs, Roger C. W.; de Jong, Paulus T. V. M.; Oostra, Ben A.; Paterson, Andrew D.; Mackey, David A.; Bergen, Arthur A. B.; Reis, Andre; Hammond, Christopher J.; Vingerling, Johannes R.; Lemij, Hans G.; Klaver, Caroline C. W.; van Duijn, Cornelia M.

    2012-01-01

    Intraocular pressure (IOP) is a highly heritable risk factor for primary open-angle glaucoma and is the only target for current glaucoma therapy. The genetic factors which determine IOP are largely unknown. We performed a genome-wide association study for IOP in 11,972 participants from 4

  8. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  9. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  10. Role of cataract surgery in lowering intraocular pressure

    International Nuclear Information System (INIS)

    Ahmad, S.; Sabih, A.

    2015-01-01

    To study the effects of cataract surgery in lowering of intraocular pressure (IOP). Study Design: Retrospective study. Place and Duration of Study: The Department of Ophthalmology, Combined Military Hospital, Rawalpindi from January 2011 to December 2013. Patients and Methods: The study included a total of 250 patients; of which 100 cases had simple cataract with no coexisting disease, 100 cases had cataract with primary open angle glaucoma and 50 cases of cataract had accompanying pseudoexfoliation glaucoma. All patients were assessed and recorded preoperatively for their IOP, vision, depth of anterior chamber (ACD), angle of anterior chamber by gonioscopy and glaucoma medications being used. Cataract surgery was performed by phacoemulsification and IOL implantations in all cases. These patients were followed up for a period of six months. Results: The intraocular ressure of all these patients was recorded at monthly interval for six months. The IOP showed a significant decrease in all cases and remained constant till the end of the study. A marked improvement of vision was noted in all cases. The depth of the anterior chamber increased and the angle also widened in all cases. Discussion: Cataract surgery has been found to reduce IOP along with improvement in vision. Patients with glaucoma have a dual benefit of reduced IOP and visual improvement after cataract surgery. (author)

  11. In vitro study of antibiotic effect on bacterial adherence to acrylic intraocular lenses.

    Science.gov (United States)

    Gaál, Valéria; Kilár, Ferenc; Acs, Barnabás; Szijjártó, Zsuzsanna; Kocsis, Béla; Kustos, Ildikó

    2005-11-10

    Implantation of artificial intraocular lenses into the eye during ophthalmic surgical procedures ensures an unliving surface on which bacterial pathogens may attach and form biofilms. Despite antibiotic treatment bacteria growing in biofilms might cause inflammation and serious complications. In this study the adhesive ability of 7 Staphylococcus aureus and 11 coagulase-negative Staphylococcus (CNS) strains to the surface of acrylic intraocular lenses had been examined by the ultrasonic method. In untreated cases adhesion of the S. aureus and CNS strains did not differ significantly. We could not demonstrate significant differences between the adhesive ability of the standard strains and the clinical isolates. In this study a single--60 min long--antibiotic (ciprofloxacin and tobramycin) treatment had been applied, that correlate well with the single or intermittant antibiotic prophylaxis of patients. Ciprofloxacin administration was able to reduce significantly the number of attached cells on the surface of acrylic lenses both in the case of S. aureus and CNS strains. Dependence of the effect from concentration could also be demonstrated. Tobramycin treatment was able to inhibit significantly the attachment of S. aureus cells. Despite the debate on antibiotic prophylaxis we presented in our experiments that a single antibiotic administration can decrease the attachment of bacterial cells to the surface of acrylic intraocular lenses, and might be effective in the prevention of postoperative endophthalmitis, that is a rare but serious complication of ophthalmic surgery.

  12. Assessment of intraocular pressure in chinchillas of different age groups using rebound tonometry

    Directory of Open Access Journals (Sweden)

    Flor Diana Yokoay Claros Chacaltana

    2016-01-01

    Full Text Available ABSTRACT: The aim of this research was to measure the intraocular pressure (IOP of normal chinchilla eyes using the rebound tonometer. A further aim was to assess whether there were differences in the values of intraocular pressure in relation to animals age, gender and time of day. Thirty-six chinchillas were divided into three groups of 12 chinchillas each, by age: Group I (2-6-month-old, Group II (20 and 34 months and Group III (37 and 135 months. Ophthalmic examination was performed previously by Schirmer tear test, slit lamp biomicroscopy, indirect ophthalmoscopy and fluorescein test in all chinchillas. Three measurements of intraocular pressure were assessed on the same day (7, 12 and 19h. Tonometry was performed on both eyes using the rebound tonometer after calibration in "p" mode. Statistical analysis was performed with SigmaPlot for Windows. The mean IOP for groups I, II and III were 2.47±0.581mmHg, 2.47±0.581mmHg and 2.51±0.531mmHg, respectively. No significant differences were reported between age and IOP and no significant differences were reported between the time of day and IOP. The IOP in chinchillas did not differ significantly between genders or ages of the animals, and did not change with time of day.

  13. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P

    2012-04-01

    To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.

  14. Calidad visual en pacientes con lente intraocular multifocal modelo OcuFlex operados de catarata The quality of vision in patients operated on from cataract and implanted with OcuFlex multifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Eneida Pérez Candelaria

    2010-01-01

    Full Text Available OBJETIVO: Describir la calidad visual en 8 pacientes operados de catarata bilateral con la técnica de Faco-chop e implante de lente intraocular multifocal modelo OcuFlex, en el ICO "Ramón Pando Ferrer", desde septiembre 2007 a febrero 2008. MÉTODOS: Se realizó un estudio observacional, descriptivo, longitudinal y prospectivo para lo cual se analizaron variables como equivalente esférico, sensibilidad al contraste en el preoperatorio y posoperatorio; fenómenos visuales, centrado y localización del lente intraocular, así como el estado de satisfacción subjetiva de los pacientes. Se utilizó la estadística descriptiva con ayuda del sistema Microsoft Excel y Word 2003, para Windows XP. RESULTADOS: El equivalente esférico medio posoperatorio fue -0,59 tanto para frecuencias bajas como medias, en visión binocular la sensibilidad al contraste media fue de 1,12 unid.log en el preoperatorio y de 1,74 unid.log. en el posoperatorio. Por biomicroscopia con lámpara de hendidura en el 100 % de los casos el lente intraocular estaba centrado y por biomicroscopia ultrasónica el 93,75 % se encontraba en el saco capsular. Ningún paciente refirió la presencia de glare y solamente uno (12,5 % reportó visión de halos nocturnos. La totalidad de los pacientes se manifestaron satisfechos. CONCLUSIONES: Los lentes multifocales disminuyen la dependencia de las gafas después de la cirugía de catarata, razón por la que constituye una buena opción en la recuperación de la función visual óptima.OBJECTIVE: To describe the quality of vision in 8 patients, who were operated on from bilateral cataract using Phaco-chop technique and implanted with Ocuflex multifocal intraocular lens in "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from September 2007 to February 2008. METHODS: A prospective, longitudinal, observational and descriptive study was made in which the variables spheral equivalent, contrast sensitivity in the pre- and post

  15. Correlación entre la localización del lente intraocular, según biomicroscopia ultrasónica,y diferentes parámetros quirúrgicos en pacientes operados de catarata Correlation between the location of the intraocular lens according to ultrasonic biomicroscopy and several surgical parameters in patients operated from cataract

    Directory of Open Access Journals (Sweden)

    Eneida de la C Pérez Candelaria

    2010-01-01

    Full Text Available OBJETIVO: Determinar la correlación entre la localización del lente intraocular en cámara posterior por biomicroscopia ultrasónica, diferentes parámetros quirúrgicos en pacientes operados de catarata. MÉTODOS: Se realizó un estudio descriptivo, prospectivo y transversal en el Instituto Cubano de Oftalmología «Ramón Pando Ferrer», durante el período de enero a junio del 2007. Se estudiaron variables como: edad, sexo, etiología de la catarata, técnica quirúrgica, localización del lente intraocular según biomicroscopia ultrasónica, así como complicaciones transoperatorias y posoperatorias. RESULTADOS: El 79 % de todos los pacientes operados tenían entre 60 y 79 años de edad y algo más de la mitad correspondió al sexo femenino con un 59 %. La catarata senil fue la etiología que predominó con un 74 % y en el 68 % de los casos el lente se localizó por biomicroscopia ultrasónica en el saco capsular. En los ojos donde el lente intraocular se localizó fuera del saco, la proporción de complicaciones transoperatorias y posoperatorias fueron significativamente mayoritarias, mientras que en los ojos donde el lente intraocular se encontraba en el saco, la mayoría no presentó complicaciones transoperatorias ni posoperatorias. CONCLUSIONES: Las diferencias entre las distintas localizaciones del lente intraocular se encontraron con significación estadística en el tipo de catarata, la presencia de complicaciones transoperatorias y posoperatorias, sin embargo, no se encontró relación estadística significativa entre la localización del lente intraocular con la técnica quirúrgica utilizada.OBJECTIVE: To determine the correlation between the location of the intraocular lens in the posterior chamber using ultrasonic biomicroscopy and the different surgical parameters in patients operated from cataract. METHODS: A prospective, descriptive and cross-sectional study was carried out in "Ramón Pando Ferrer" Cuban Institute of

  16. Clinical study of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes

    Directory of Open Access Journals (Sweden)

    Ru-Fa Meng

    2015-07-01

    Full Text Available AIM: To investigate the operation methods and clinical effects of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes.METHODS: During January 2012 to January 2014, foldable intraocular lens was implanted on 47 cases following lens-vitrectomy in residual capsular with traumatic eyes 3~6mo. Follow-up period was 6~12mo, averaged(8.21±2.63mo. RESULTS:All of 47 eyes had successful operation at one time, and position deviation was not appeared. The naked vision of the last postoperative follow-up was(0.44±0.19. Compared with best corrected visual acuity(0.41±0.23, and There was no significant difference between visual acuity of preoperative and last follow-up period(t=0.879, P=0.342. No severe complication was found. CONCLUSION: Secondary implantation of foldable intraocular lens is a safe and reliable method for correcting ametropia after lens-vitrectomy in residual capsular with traumatic eyes.

  17. Lessons learned: wrong intraocular lens.

    Science.gov (United States)

    Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P

    2012-10-01

    To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Could White Coat Ocular Hypertension Affect to the Accuracy of the Diagnosis of Glaucoma? Relationships Between Anxiety and Intraocular Pressure in a Simulated Clinical Setting.

    Science.gov (United States)

    Méndez-Ulrich, Jorge Luis; Sanz, Antoni; Feliu-Soler, Albert; Álvarez, María; Borràs, Xavier

    2018-03-01

    Sixty-one healthy subjects participated in a laboratory study carried out in a simulated clinical setting. Anticipatory anxiety-state was assessed at the arrival and immediately after, with no brief phase of adaptation, measurements of intraocular pressure, heart rate, systolic and diastolic blood pressure were collected. At the end of the procedure, anxiety-trait was also assessed. Results suggest that high levels of both anxiety-state and anxiety-trait significantly predicted a clinically relevant increase of intraocular pressure. Anxiety-state mediated the relationship between anxiety-trait and intraocular pressure, which also was found to be related with heart rate but not related to both systolic and diastolic blood pressure. These results suggest a common mechanism of regulation underlying anxiogenic variability found on both intraocular pressure and heart rate. A reduction in parasympathetic activity appears as a possible mechanism underlying to this phenomenon. This anxiety-enhanced intraocular pressure could be considered a phenomenon analogous to white coat hypertension found in the measurement of blood pressure; therefore, it probably should be taken into account in the clinical context to prevent errors in the diagnosis of glaucoma. Further research on cognitive and emotional regulation of intraocular pressure is needed to best characterize this hypothetical phenomenon.

  19. Clinical research of phacoemulsification with posterior chamber intraocular lens implantation for glaucoma with different goniosynechia ranges

    Directory of Open Access Journals (Sweden)

    Qing-Yu Li

    2016-02-01

    Full Text Available AIM:To study the effect of phacoemulsification with posterior chamber intraocular lens implantation to treat glaucoma with different angle-closure range, which may provide a better way to treat the angle-closure glaucoma.METHODS:There were 47 cases(54 eyeswith angle-closure glaucoma, and all of them underwent phacoemulsification and posterior chamber intraocular lens implantation. According to the range of goniosynechia, these patients were divided into three groups:the eyes with the range of goniosynechia≤1/2 were group A(13 eyes; the eyes with 1/23/4 were group C(23 eyes. We observed the status of anterior chamber angle and the intraocular pressure(IOPof the three groups at 2wk after operations. RESULTS:Compared to the preoperative condition, the IOP of the three groups at 2wk after operations decreased significantly. The IOP reductions of group B and C were more significant than that of group A, and the differences were significant(PPP3/4 appeared in group B; in group C, there were 5 eyes with goniosynechia>3/4, 1 eye with disappeared anterior chamber, 3 eyes with corneal edema, 1 eye with choroidal hemorrhage. The differences of postoperative complication rate among the three groups was statistically significant(PPCONCLUSION:For patients with angle closure glaucoma who have mild to moderate goniosynechia, phacoemulsification with posterior chamber intraocular lens implantation is an effective way. After operations, their closed anterior angle reopened. But to the patients with severe adhesions, there are more complications after operations, especially the glaucoma may reoccur.

  20. Simple technique to treat pupillary capture after transscleral fixation of intraocular lens.

    Science.gov (United States)

    Jürgens, Ignasi; Rey, Amanda

    2015-01-01

    We describe a simple surgical technique to manage pupillary capture after previous transscleral fixation of an intraocular lens. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Subluxação congênita do cristalino: resultados visuais e posição das lentes intraoculares após a cirurgia Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position

    Directory of Open Access Journals (Sweden)

    Caroline Arraes

    2010-04-01

    Full Text Available OBJETIVO: Avaliar os resultados visuais e investigar, através da biomicroscopia ultrassônica, o posicionamento das lentes intraoculares e do anel endocapsular em 17 olhos de 10 portadores de subluxação congênita do cristalino, submetidos à mesma técnica cirúrgica pelo mesmo cirurgião. MÉTODOS: O estudo foi realizado no Hospital de Olhos de Pernambuco e Fundação Altino Ventura. A técnica cirúrgica consistiu em facoaspiração com implante de anel endocapsular e de lentes intraoculares com amputação de uma das alças. A idade variou entre 7 e 22 anos. Foram coletados dados sobre acuidade visual para longe pré e pós-operatória, tempo de seguimento após a cirurgia e complicações. Os pacientes foram submetidos à biomicroscopia ultrassônica. RESULTADOS: O tempo de seguimento médio foi de 2,8 anos. Houve melhora da acuidade visual para longe nos 17 (100% olhos: 12 olhos (70,6% apresentaram acuidade visual para longe melhor que 20/40; 4 (23,5% apresentaram acuidade visual para longe entre 20/40 e 20/100 e 1 (5,9% apresentou acuidade visual para longe pior que 20/100, porém melhor que acuidade visual para longe pré-operatória. A opacificação da cápsula posterior ocorreu em 10 olhos (58,9%. Na biomicroscopia ultrassônica observou-se que todas as lentes intraoculares estavam parcialmente descentralizadas, contudo sem atingir o bordo pupilar. Em todos os casos observou-se um adequado posicionamento do anel e um bom suporte capsular. CONCLUSÃO É possível concluir que o tratamento cirúrgico avaliado proporciona uma boa centralização das lentes intraoculares e do anel endocapsular, com melhora da acuidade visual para longe, sendo uma opção viável, eficaz e segura na reabilitação visual dos pacientes com subluxação congênita do cristalino.PURPOSE: To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients

  2. Analysis of causes of intraocular lens explantations in the material of Department of Ophthalmology, Medical University of Lodz.

    Science.gov (United States)

    Wilczyński, Michał; Wilczyńska, Olena; Omulecki, Wojciech

    2009-01-01

    Implantation of intraocular lenses (IOLS) has become a standard practice in cataract surgery, however, similar to any other type of surgery, using IOLs is not complication-free and sometimes explantation of intraocular lenses may be necessary. This study was to gather data and analyze causes of intraocular lens explantations, performed in the Department of Ophthalmology, Medical University of Łódź. The data were gathered from medical documentation of all patients who underwent intraocular lens removal from January 2003 to July 2006. The examined group consisted of 16 patients (16 eyes): 9 women (fraction 0.56), and 7 men (fraction 0.44), at the age from 21 to 82 years (mean age 62.4 years, SD +/- 15.5). In all patients IOL explantation was performed under local, peribulbar anaesthesia. Two groups of patients were distinguished: patients who had an anterior chamber lens explanted (3 patients, fraction 0.19) and patients who underwent posterior chamber lens explantation (13 patients, fraction 0.81). Causes of AC IOL explantations were: vaulting of the IOL (1 eye, fraction 0.06), luxation of the IOL to the vitreous cavity (1 eye, fraction 0.06), and painful eyeball after anterior chamber lens implantation (1 eye, fraction 0.06). Causes of PC IOL explantations were: subluxation of the IOL (6 eyes, fraction 0.38), luxation of the lens to the vitreous cavity (3 eyes, fraction 0.19), luxation of the lens to the anterior chamber (1 eye, fraction 0.06), endophthalmitis (2 eyes, fraction 0.13) and incorrect lens power (1 eye, fraction 0.06). In the majority of eyes (n = 13, fraction 0.81) the removed implant was replaced by another intraocular lens, but 3 eyes (fraction 0.19) were left aphakic. We did not observe serious intra- or early postoperative complications which might influence the final result of the operation.

  3. LONG-TERM INTRAOCULAR PRESSURE AFTER UNCOMPLICATED PARS PLANA VITRECTOMY FOR IDIOPATHIC EPIRETINAL MEMBRANE.

    Science.gov (United States)

    Tognetto, Daniele; Pastore, Marco R; Cirigliano, Gabriella; DʼAloisio, Rossella; Borelli, Massimo; De Giacinto, Chiara

    2017-11-16

    To investigate long-term intraocular pressure trends after uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane. Three hundred and sixty-eight eyes of 368 consecutive patients were enrolled. Changes in intraocular pressure 1, 3, 6, and 12 months after surgery and during the final follow-up visit were evaluated in vitrectomized eyes and nonvitrectomized fellow eyes. The median follow-up period was 36 months (range 12-92 months). Longitudinal data analysis evidenced a 2.5-mmHg (2.2 mmHg; 2.7 mmHg, 95% confidence interval) statistically significant difference in intraocular pressure 30 days after surgery between treated and fellow untreated eyes, gradually recovering to a not significant 0.2-mmHg (-0.1 mmHg; 0.4 mmHg, 95% confidence interval) difference within 26 months. The incidence of late-onset ocular hypertension was 5.7% (21 over 347, 2%; 12%, 95% confidence interval) without difference between the treated eyes and the group control. No significant difference in the incidence of late-onset ocular hypertension and sex, lens status, or gauge of vitrectomy instruments was detected. Only patient's age was significantly higher (mean difference 4.2 years; 0.1-8.0 years, Monte Carlo, 95% confidence interval) in those who developed late-onset ocular hypertension in the vitrectomized eye. Uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane seems not to increase the risk of late-onset ocular hypertension or open-angle glaucoma development.

  4. Intraocular lens subluxation in a patient with facial atopic dermatitis.

    Science.gov (United States)

    Yamazaki, S; Nakamura, K; Kurosaka, D

    2001-02-01

    A 66-year-old Japanese man presented with subluxation of a posterior chamber intraocular lens (IOL) caused by a rupture of part of Zinn's zonule but no retinal break 2 years after phacoemulsification with IOL implantation. He had a history of atopic dermatitis since infancy. This case presents a rare ocular complication of scratching and rubbing the face and eyelids because of itching related to atopic dermatitis.

  5. Intraocular pressure measurements after conductive keratoplasty.

    Science.gov (United States)

    Kymionis, George D; Naoumidi, Tatiana L; Aslanides, Ioannis M; Kumar, Vinod; Astyrakakis, Nikolaos I; Tsilimbaris, Miltiadis; Pallikaris, Ioannis G

    2005-01-01

    To determine the possible impact of conductive keratoplasty (CK) on intraocular pressure (IOP) measurements. A prospective, single-center, noncomparative interventional case series was performed. Baseline and postoperative IOPs were measured by Goldmann applanation tonometry in 32 eyes of 18 patients who underwent CK for hyperopia correction. Mean follow-up was 11.9 months (range: 8 to 18 months). After CK, a statistically significant decrease in the measured IOP was observed (before CK: 14.22+/-1.64 vs after CK: 12.66+/-2.21, P<.001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or attempted correction. Despite the limitations due to the small number of patients enrolled in this study, the applanation tonometer appears to underestimate the true IOP after CK.

  6. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

    Science.gov (United States)

    Olsen, Thomas

    2007-02-01

    This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p ultrasound, respectively (p power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.

  7. Net technique for intraocular lens support in aphakia without capsular support.

    Science.gov (United States)

    De Novelli, Fernando José; Neto, Theodomiro Lourenço Garrido; de Sena Rabelo, Gabriel; Blumer, Marcel Eduardo; Suzuki, Ricardo; Ghanem, Ramon Coral

    2017-01-01

    This paper describes a modified surgical technique for intraocular lens implantation in aphakic eyes with no capsular support. Retrospective case series. Seventeen eyes of 17 aphakic patients with no capsule support underwent intraocular lens (IOL) implantation using a standardized technique in which a net was created at the ciliary sulcus plane with two threads forming a net pattern. The net was used as support for the IOL. Follow-up ranged from 6 to 38 months, with an average of 23 months. In all cases, the IOL was safely implanted and remained stable during the follow-up. In 16 eyes, the IOL remained well centered; in one eye, slight decentration was observed. Distance-corrected visual acuity improved by a mean of 4 lines, from 1.13 (LogMAR) to 0.52 (P = 0.01). This technique might be especially useful in cases of insufficient capsular support associated with tissue loss or iris atrophy. In these cases, iris fixation is not feasible; thus, the only surgical alternative is IOL scleral fixation.

  8. Single suture iris-to-capsulorhexis fixation for in-the-bag intraocular lens subluxation.

    Science.gov (United States)

    Siegel, Michael J; Condon, Garry P

    2015-11-01

    We present a simplified modification to a technique for early or mild in-the-bag subluxation that avoids conjunctival and scleral incisions and minimizes intraocular manipulation. While the capsulorhexis edge is grasped with an intraocular forceps to stabilize the IOL-capsular bag complex, a 10-0 polypropylene suture on a long curved needle is used to secure the fibrotic superior capsulorhexis edge to the midperipheral iris at 12 o'clock using a combination of a modified McCannel suture and a Siepser sliding knot. Dr. Condon receives speaker and consultant fees from Alcon Surgical, Inc., Allergan, Inc., and Microsurgical Technology. Although the Microsurgical Technology Condon snare instrument is named after him, Dr. Condon reports no patents, fees, or payments related to it. Dr. Siegel has no financial or proprietary interest in any material or method mentioned. Copyright © 2015. Published by Elsevier Inc.

  9. Clinical application of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract

    Directory of Open Access Journals (Sweden)

    Qing-Song Gao

    2018-02-01

    Full Text Available AIM:To evaluate the effect of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract. METHODS: Totally 86 cases(106 eyesof patients with double cataract in our hospital from January 2016 to January 2017 were selected, including 49 cases(59 eyeswere set as the observation group(treated with femtosecond laser assisted phacoemulsification combined with triple-focus intraocular lens implantation, and 37 cases(47 eyeswere set as the control group(received traditional phacoemulsification combined with triple-focus intraocular lens implantation. Corneal endothelial cell density, cumulative dissipated energy(CDE, distant and near visual accommodation before and after operation were compared between the two groups, postoperative complications were observed. RESULTS: The preoperative corneal endothelial cell density of two groups had no significant difference(P>0.05. The corneal endothelial cell density of two groups significantly decreased at postoperative 1wk, with statistic significance within groups(PPPPPP>0.05. The incidence of glare and halo in the observation group was 10.2% and 8.5% in the control group, and are in the patients whose age was above 60 years old, there was no significant difference between the two groups(P>0.05. CONCLUSION: Femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract can not only improve curative effect, but also provide high safety, while the adverse events including glare, halo and other adverse visual circumstances should be considered after triple-focus intraocular lens implantation.

  10. The Comparison of the Influence of Thiopental and Propofol on Intraocular Pressure during Induction of Anesthesia in Intubated Patients under Cataracct Surgery

    Directory of Open Access Journals (Sweden)

    Reza Sahraei

    2016-07-01

    Full Text Available The prevention of the increase of intraocular pressure and the further decrease of it during eye surgery has an impressive effect on the success of surgery. Some of the phases of the induction of anesthesia like laryngoscopy and tracheal intubation result in the increase of intraocular pressure and its consequences are dangerous for penetrating injuries of eyeball. The goal of this research is the comparison of the changes of intraocular pressure during the induction of anesthesia in completely same conditions by using thiopental and propofol and also the careful investigation of their influences on intraocular pressure in order to select the medicine that effectively decrease the intraocular pressure and prevent the increase of it after laryngoscopy and tracheal intubation. In this research, 88 patients were selected and they were randomly divided into 2 groups. In the beginning of the patients' anesthesia, both groups were preoxygenated and they simultaneously receive initial dose of atracurium (0/5 mg/kg and then initial dose of fentanyl (1-2 µg/Kg. After prescription of fentanyl, the induction of anesthesia in the first group was done withthiopental (4 mg/kg and in the second group with propofol (2/5 mg/kg and after that, atracurium intubation (0/7 mg/kg was prescribed. Intraocular pressure is measured in two phases before induction of anesthesia (with tetracaine eyedrop and 3 minutes after intubation (with schiotz tonometer and 3±0/75 degree of accuracy and by a person who is not aware of the kind of anesthesia. The patients are replicated in 2 experimental and control groups in terms of age and gender. The results of independent t-test show that there is no significant difference between 2 groups of thiopental and propofol in terms of systolic and diastolic blood pressure, heart beat and eye pressure before the induction of anesthesia (p-value>0,05. The results of independent t-test show that there is a significant difference between2

  11. Two cases of uveitis masquerade syndrome caused by bilateral intraocular large B-cell lymphoma

    Directory of Open Access Journals (Sweden)

    Jovanović Svetlana

    2013-01-01

    Full Text Available Introduction. Sometimes it is not easy to clinically recognize subtle differences between intraocular lymphoma and noninfectious uveitis. The most common lymphoma subtype involving the eye is B-cell lymphoma. Case report. We presented two patients aged 59 and 58 years with infiltration of the subretinal space with a large B-cell non-Hodgkin intraocular lymphoma. The patients originally had clinically masked syndrome in the form of intermediate uveitis. As it was a corticosteroid-resistant uveitis, we focused on the possible diagnosis of neoplastic causes of this syndrome. During hospitalization, the neurological symptoms emerged and multiple subretinal changes accompanied by yellowish white patches of retinal pigment epithelium with signs of vitritis, which made us suspect the intraocular lymphoma. Endocranial magnetic resonance imaging established tumorous infiltration in the region of the left hemisphere of the cerebellum. The histopathological finding confirmed the diagnosis of large B-cell non-Hodgkin lymphoma of risk moderate degree, immunoblast - centroblast cytological type. The other patient had clinical chronic uveitis accompanied by yellowish shaped white echographic changes of the retina and localized changes in the level of the subretina. The diagnosis of lymphoma was made by brain biopsy. Conclusion. Uveitis masquerade syndrome should be considered in all patients over 40 years with idiopathic steroid-resistant uveitis. Treatment begun on time can affect the course and improve the prognosis of uveitis masquerade syndrome (UMS and systemic disease.

  12. Associations with intraocular pressure across Europe: The European Eye Epidemiology (E-3) Consortium

    NARCIS (Netherlands)

    Khawaja, Anthony P.; Springelkamp, Henriët; Creuzot-Garcher, Catherine; Delcourt, Cécile; Hofman, Albert; Höhn, René; Iglesias, Adriana I.; Wolfs, Roger C. W.; Korobelnik, Jean-François; Silva, Rufino; Topouzis, Fotis; Williams, Katie M.; Bron, Alain M.; Buitendijk, Gabriëlle H. S.; Cachulo, Maria da Luz; Cougnard-Grégoire, Audrey; Dartigues, Jean-François; Hammond, Christopher J.; Pfeiffer, Norbert; Salonikiou, Angeliki; van Duijn, Cornelia M.; Vingerling, Johannes R.; Luben, Robert N.; Mirshahi, Alireza; Lamparter, Julia; Klaver, Caroline C. W.; Jansonius, Nomdo M.; Foster, Paul J.; Acar, Niyazi; Anastosopoulos, Eleftherios; Azuara-Blanco, Augusto; Bergen, Arthur; Bertelsen, Geir; Binquet, Christine; Bird, Alan; Brétillon, Lionel; Bron, Alain; Buitendijk, Gabrielle; Cachulo, Maria Luz; Chakravarthy, Usha; Chan, Michelle; Chang, Petrus; Colijn, Annemarie; Cumberland, Philippa; Cunha-Vaz, José; Daien, Vincent; Deak, Gabor; Delyfer, Marie-Noëlle; Hollander, Anneke den; Dietzel, Martha; Erke, Maja Gran; Fauser, Sascha; Finger, Robert; Fletcher, Astrid; Foster, Paul; Founti, Panayiota; Göbel, Arno; Gorgels, Theo; Grauslund, Jakob; Grus, Franz; Hammond, Christopher; Helmer, Catherine; Hense, Hans-Werner; Hermann, Manuel; Hoehn, René; Hogg, Ruth; Holz, Frank; Hoyng, Carel; Jansonius, Nomdo; Janssen, Sarah; Khawaja, Anthony; Klaver, Caroline; Le Goff, Mélanie; Leal, Sergio; Lechanteur, Yara; Lehtimäki, Terho; Lotery, Andrew; Leung, Irene; Mauschitz, Matthias; Merle, Bénédicte; Meyer Zu Westrup, Verena; Midena, Edoardo; Miotto, Stefania; Mohan-Saïd, Sadek; Muldrew, Alyson; Mueller, Michael; Nunes, Sandrina; Oexle, Konrad; Peto, Tunde; Piermarocchi, Stefano; Prokofyeva, Elena; Rahi, Jugnoo; Raitakari, Olli; Ribeiro, Luisa; Rougier, Marie-Bénédicte; Sahel, José; Salonikiou, Aggeliki; Sanchez, Clarisa; Schmitz-Valckenberg, Steffen; Schweitzer, Cédric; Segato, Tatiana; Shehata, Jasmin; Silvestri, Giuliana; Simader, Christian; Souied, Eric; Springelkamp, Henriet; Tapp, Robyn; Verhoeven, Virginie; Von Hanno, Therese; Vujosevic, Stela; Williams, Katie; Wolfram, Christian; Yip, Jennifer; Zerbib, Jennyfer; Zwiener, Isabella

    2016-01-01

    Raised intraocular pressure (IOP) is the most important risk factor for developing glaucoma, the second commonest cause of blindness globally. Understanding associations with IOP and variations in IOP between countries may teach us about mechanisms underlying glaucoma. We examined cross-sectional

  13. Recent decreasing frequency of enucleation for intraocular retinoblastoma in Upper Egypt

    International Nuclear Information System (INIS)

    Abdallh, A.M.

    2006-01-01

    To evaluate the efficacy of combined systematic chemotherapy (chemoreduction) and local ophthalmic therapy (LT) is preventing or delaying external beam radiotherapy (EBRT) and enucleation in patients with intraocular retinoblastoma. This was a prospective, nonrandomized, single-institution, clinical study. Twenty-eight patients (37 eyes) with newly diagnosed intraocular retinoblastoma were included in this study. Primary enucleation was performed for 7 eyes with advanced intraocular retinoblastoma at presentation before starting chemoreduction. Using Reese-Ellsworth (RE) staging for RB, the remaining 30 eyes were as follows: Two in group I, 3 in group II, 8 in group III, 7 in group IV, and 9 in group V. All the 30 eyes were initially treated with 6 cycles of chemoredution using vincristine, etoposide and carboplatin, repeated every three weeks. After total of 6 cycles, each tumor was re-evaluated decide on the next mode of therapy. In cases where the tumor was reduced enough, LT (Thermotherapy, or cryotherapy, but plaque radiotherapy was unavailable) was applied. In cases where the tumor was reduced but insufficient for LT, we added another 3 cycles of same regimen in some patients; or we performed chemotherapy (CTT) for others, according to size of the residual tumor. Eyes failed to respond to tochemorduction and LT, received EBRT or were enucleated. Following 6 cycles of chemoreduction, all tumors showed an initial regression, and all vitreous and subretinal seeds showed calcification or disappearance of most of them. Among the 30 eyes, 12 eyes achieved complete response (CR), and 18 eyes achieved partial response (PR). Only 7 eyes (stage I to III) showed sufficient reduction of tumor size for the LT to be applied for, for which, TTT (4 eyes), and cryotherapy (3 eyes) were performed. Chemotherapy (CTT) was performed for 9 patients (13 eyes, 15 tumors). At the end of follow-up period, 14 of the total 30 eyes (46.7%) could not be salvaged with chemoreduction and LT

  14. Combined Acute Haemolytic and Secondary Angle Closure Glaucoma following Spontaneous Intraocular Haemorrhages in a Patient on Warfarin

    Directory of Open Access Journals (Sweden)

    Walter Andreatta

    2016-11-01

    Full Text Available Background: To report the first described case of combined haemolytic and acute angle closure glaucoma secondary to spontaneous intraocular haemorrhages in a patient on excessive anticoagulation. To the best of our knowledge, this is the first case reported in the literature presenting with raised intraocular pressure due to both mechanisms. Case Description: A 90-year-old woman presented with acute pain and reduction in vision in the left eye. Her intraocular pressure (IOP was 55 mm Hg. There were red tinted blood cells in the anterior chamber giving it a reddish hue. The patient was known to have advanced wet macular degeneration. She was taking oral warfarin for atrial fibrillation. Her international normalised ratio (INR was 7.7. B-scan ultrasound of posterior segment showed vitreous and suprachoroidal haemorrhages. An ultrabiomicroscopic examination confirmed open angles. A diagnosis of haemolytic glaucoma secondary to intraocular haemorrhages was made. The IOP was controlled medically. Warfarin was withdrawn and oral vitamin K therapy was initiated leading to a rapid INR reduction. Three days later, her anterior chamber became progressively shallower causing a secondary acute angle closure which was managed medically. After 2 months, the left IOP was well-controlled without any medications and the eye was not inflamed. Her vision in that eye remained perception of light. Conclusion: Patients with suprachoroidal haemorrhages should be closely monitored as they might subsequently develop acute angle closure despite an initially open angle and well-controlled INR and IOP. Excessive anticoagulation needs to be prevented to minimise the risk of sight-threatening complications.

  15. Effect of Topical Calcium Channel Blockers on Intraocular Pressure in Steroid-induced Glaucoma.

    Science.gov (United States)

    Ganekal, Sunil; Dorairaj, Syril; Jhanji, Vishal; Kudlu, Krishnaprasad

    2014-01-01

    To evaluate the effect of 0.125% verapamil and 0.5% diltiazem eye drops on intraocular pressure (IOP) in steroid-induced glaucoma in rabbit eyes. A total of 18 rabbits with steroid-induced glaucoma were divided into three groups (A, B and C; n = 6 each). Right eyes in groups A, B and C received 0.5% diltiazem, 0.125% verapamil and 0.5% timolol eye drops twice daily for 12 days, respectively; whereas, left eyes received distilled water. IOP was measured with Tono-pen XL at baseline, day 4, day 8, and day 12 of treatment. Both 0.5% diltiazem and 0.125% verapamil eye drops significantly reduced IOP compared to control eyes (p cite this article: Ganekal S, Dorairaj S, Jhanji V, Kudlu K. Effect of Topical Calcium Channel Blockers on Intraocular Pressure in Steroid-induced Glaucoma. J Current Glau Prac 2014;8(1):15-19.

  16. Mechanical properties of intra-ocular lenses

    Science.gov (United States)

    Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie

    2008-02-01

    Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements

  17. Comparison of current tonometry techniques in measurement of intraocular pressure.

    Science.gov (United States)

    Kouchaki, Behrooz; Hashemi, Hassan; Yekta, Abbasali; Khabazkhoob, Mehdi

    2017-06-01

    To compare four tonometry techniques: Goldmann applanation tonometer (GAT), Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response Analyzer (ORA) in the measurement of intraocular pressure (IOP) and the impact of some corneal biomechanical factors on their performance. In this cross-sectional study, volunteers with normal ophthalmic examination and no history of eye surgery (except for uncomplicated cataract surgery) or trauma were selected. Twenty-five subjects were male, and 21 were female. The mean age was 48 ± 19.2 years. Anterior segment parameters were measured with Scheimpflug imaging. IOP was measured with GAT, DCT, NCT, and ORA in random order. A 95% limit of agreement of IOPs was analyzed. The impact of different parameters on the measured IOP with each device was evaluated by regression analysis. The average IOP measured with GAT, DCT, NCT, and ORA was 16.4 ± 3.5, 18.1 ± 3.4, 16.2 ± 3.9, and 17.3 ± 3.4 mmHg, respectively. The difference of IOP measured with NCT and GAT was not significant ( P  = 0.382). Intraocular pressure was significantly different between GAT with DCT and IOP CC ( P  tonometers.

  18. Application of polymerase chain reaction to differentiate herpes simplex virus 1 and 2 serotypes in culture negative intraocular aspirates

    Directory of Open Access Journals (Sweden)

    Shyamal G

    2005-01-01

    Full Text Available Purpose: To standardize and apply a polymerase chain reaction (PCR on the glycoprotein D gene to differentiate Herpes simplex virus (HSV 1 & 2 serotypes in culture negative intraocular specimens. Methods: Twenty-one intraocular fluids collected from 19 patients were subjected to cultures for HSV and uniplex PCR (uPCR for DNA polymerase gene. To differentiate HSV serotypes, as 1 & 2, a seminested PCR (snPCR targeting the glycoprotein D gene was standardised and applied onto 21 intraocular fluids. The specificity of the snPCR was verified by application onto ATCC strains of HSV 1 and 2, clinical isolates and DNA sequencing of the amplified products. All specimens were also tested for the presence of cytomegalovirus (CMV and varicella zoster virus (VZV by nucleic acid amplification methods. Results: Four of the 21 intraocular fluids were positive for HSV by uPCR. snPCR detected HSV in three additional specimens (total of seven specimens, and identified three as HSV 1 and four as HSV 2. DNA sequencing of PCR products showed 100% homology with the standard strains of HSV 1 and 2 respectively. None of the samples were positive in culture. Among the other patients, CMV DNA was detected in two and VZV DNA in five others. Conclusions: The standardized snPCR can be applied directly onto the culture negative specimens for rapid differentiation of HSV serotypes.

  19. [To exercise caution in developing intraocular lens exchange].

    Science.gov (United States)

    Song, X D; Wang, X Z; Qian, J

    2018-05-11

    Nowadays cataract extraction combined intraocular lens (IOL) implantation has become the conventional treatment for cataract. Numbers of IOL exchange after cataract extraction combined IOL implantation have been increasing in recent years. As a non-routine surgery, IOL exchange is normally combined with other surgeries and accompanied by some complications to various extents. Is IOL exchange necessary for all abnomal IOLs? Can IOL exchange be avoided? How to avoid IOL exchange? The purpose of this article is to stress the importance of indication of IOL exchange and how to avoid IOL exchange. (Chin J Ophthalmol, 2018, 54: 324-327) .

  20. Management of subluxated capsular bag-fixated intraocular lenses using a capsular anchor

    NARCIS (Netherlands)

    Ton, Yokrat; Naftali, Modi; Lapid Gortzak, Ruth; Assia, Ehud I.

    2016-01-01

    We describe the use of the capsular anchor (AssiAnchor) to manage a subluxated intraocular lens (IOL) in the capsular bag. The anchor comprises 2 prongs that hold the anterior lens capsule and a central rod that is sutured to the scleral wall, enabling centration of the IOL-capsular bag complex. Six

  1. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  2. Study on the pathogenesis of transient intraocular pressure after laser iridectomy with Krypton laser combined with Q-switched Nd:YAG laser

    Directory of Open Access Journals (Sweden)

    Zhi-Juan Pei

    2017-12-01

    Full Text Available AIM: To study the pathogenesis of transient intraocular pressure(IOPafter laser iridectomy with Krypton laser combined with Q-switched Nd:YAG laser. METHODS: Totally 42 healthy rabbits(84 eyesprovided by the Animal Experimental Center of our hospital were selected, including 18 female rabbits, 24 male rabbits, average weight 2.24±0.31kg, and they were randomly divided into 6 groups, 7 rats in each group(14 eyes. We observed the change of intraocular pressure after laser iridectomy surgery at 20min, 2, 6, 18, 24h and the nitric oxide(NO, malondialdehyde(MDA, superoxide dismutase(SOD, 6-keto-prostaglandin(6-keto-PGF1αand nitric oxide synthase(NOScontent in aqueous. RESULTS: There was no significant difference in intraocular pressure, NO, NOS, SOD, MAD and 6-keto- PGF1α before operation(P>0.05. The intraocular pressure increased after operation, and the difference was statistically significant(PP>0.05. The levels of NO, NOS and SOD in the aqueous humor of the two groups decreased 20min, 2 and 6h after the operation(PP>0.05. The levels of MDA and 6-keto-prostaglandin in the aqueous humor increased after the operation, and the difference was statistically significant at 20min, 2 and 6h after operation(PP>0.05.CONCLUSION: The increase of transient intraocular pressure after laser iridectomy may relate to the increase of malondialdehyde, 6-keto-prostaglandin content and the decrease of superoxide dismutase and nitric oxide in the aqueous humor after operation.

  3. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  4. Dynamics of intraocular IFN-γ, IL-17 and IL-10-producing cell populations during relapsing and monophasic rat experimental autoimmune uveitis.

    Directory of Open Access Journals (Sweden)

    Ulrike Kaufmann

    Full Text Available A major limitation of most animal models of autoimmune diseases is that they do not reproduce the chronic or relapsing-remitting pattern characteristic of many human autoimmune diseases. This problem has been overcome in our rat models of experimentally induced monophasic or relapsing-remitting autoimmune uveitis (EAU, which depend on the inducing antigen peptides from retinal S-Antigen (monophasic EAU or interphotoreceptor retinoid-binding protein (relapsing EAU. These models enable us to compare autoreactive and regulatory T cell populations. Intraocular, but not peripheral T cells differ in their cytokine profiles (IFN-γ, IL-17 and IL-10 at distinct time points during monophasic or relapsing EAU. Only intraocular T cells concomitantly produced IFN-γ, IL-17 and/or IL-10. Monophasic EAU presented rising numbers of cells expressing IFN-γ and IL-17 (Th1/Th17 and cells expressing IL-10 or Foxp3. During relapsing uveitis an increase of intraocular IFN-γ+ cells and a concomitant decrease of IL-17+ cells was detected, while IL-10+ populations remained stable. Foxp3+ cells and cells expressing IL-10, even in combination with IFN-γ or IL-17, increased during the resolution of monophasic EAU, suggesting a regulatory role for these T cells. In general, cells producing multiple cytokines increased in monophasic and decreased in relapsing EAU. The distinct appearance of certain intraocular populations with characteristics of regulatory cells points to a differential influence of the ocular environment on T cells that induce acute and monophasic or relapsing disease. Here we provide evidence that different autoantigens can elicit distinct and differently regulated immune responses. IFN-γ, but not IL-17 seems to be the key player in relapsing-remitting uveitis, as shown by increased, synchronized relapses after intraocular application of IFN-γ. We demonstrated dynamic changes of the cytokine pattern during monophasic and relapsing-remitting disease

  5. Cataract and keratoconus: minimizing complications in intraocular lens calculations.

    Science.gov (United States)

    Bozorg, Sara; Pineda, Roberto

    2014-01-01

    Patients with both cataract and keratoconus present unique challenges for the surgeon. Accurate keratometry (K) and axial length (AL) readings may be impossible, and uncertainty is introduced when estimating the corneal power for intraocular lens (IOL) selection. Different options on how to choose an IOL and how to manage irregular astigmatism of a keratoconic patient with cataract have been proposed and are reviewed. The stage of keratoconus and the history of the patient are both critical in determining the strategy used in treatment of cataracts.

  6. Intraocular straylight and contrast sensitivity after contralateral wavefront-guided LASIK and wavefront-guided PRK for myopia.

    Science.gov (United States)

    Barreto, Jackson; Barboni, Mirella T S; Feitosa-Santana, Claudia; Sato, João R; Bechara, Samir J; Ventura, Dora F; Alves, Milton Ruiz

    2010-08-01

    To compare intraocular straylight measurements and contrast sensitivity after wavefront-guided LASIK (WFG LASIK) in one eye and wavefront-guided photorefractive keratectomy (WFG PRK) in the fellow eye for myopia and myopic astigmatism correction. A prospective, randomized study of 22 eyes of 11 patients who underwent simultaneous WFG LASIK and WFG PRK (contralateral eye). Both groups were treated with the NIDEK Advanced Vision Excimer Laser System, and a microkeratome was used for flap creation in the WFG LASIK group. High and low contrast visual acuity, wavefront analysis, contrast sensitivity, and retinal straylight measurements were performed preoperatively and at 3, 6, and 12 months postoperatively. A third-generation straylight meter, C-Quant (Oculus Optikgeräte GmbH), was used for measuring intraocular straylight. Twelve months postoperatively, mean uncorrected distance visual acuity was -0.06 +/- 0.07 logMAR in the WFG LASIK group and -0.10 +/- 0.10 logMAR in the WFG PRK group. Mean preoperative intraocular straylight was 0.94 +/- 0.12 logs for the WFG LASIK group and 0.96 +/- 0.11 logs for the WFG PRK group. After 12 months, the mean straylight value was 1.01 +/- 0.1 log s for the WFG LASIK group and 0.97 +/- 0.12 log s for the WFG PRK group. No difference was found between techniques after 12 months (P = .306). No significant difference in photopic and mesopic contrast sensitivity between groups was noted. Intraocular straylight showed no statistically significant increase 1 year after WFG LASIK and WFG PRK. Higher order aberrations increased significantly after surgery for both groups. Nevertheless, WFG LASIK and WFG PRK yielded excellent visual acuity and contrast sensitivity performance without significant differences between techniques.

  7. Combined ab interno trabeculotomy and lens extraction: a novel management option for combined uveitic and chronic narrow angle raised intraocular pressure.

    Science.gov (United States)

    Lin, Siying; Gupta, Bhaskar; Rossiter, Jonathan

    2016-02-01

    Minimally invasive glaucoma surgery is a developing area that has the potential to replace traditional glaucoma surgery, with its known risk profile, but at present there are no randomised controlled data to validate its use. We report on a case where sequential bilateral combined ab interno trabeculotomy and lens extraction surgery was performed on a 45-year-old woman with combined uveitic and chronic narrow angle raised intraocular pressure. Maximal medical management alone could not control the intraocular pressure. At 12-month follow-up, the patient had achieved stable intraocular pressure in both eyes on a combination of topical ocular antiglaucomatous and steroid therapies. This case demonstrates the effectiveness of trabecular meshwork ablation via ab interno trabeculotomy in a case of complex mixed mechanism glaucoma. 2016 BMJ Publishing Group Ltd.

  8. Densiron® 68 as an intraocular tamponade for complex inferior retinal detachments

    Directory of Open Access Journals (Sweden)

    Hussain RN

    2011-05-01

    Full Text Available Rumana N Hussain, Somnath BanerjeeLeicester Royal Infirmary, Leicester, UKIntroduction: Densiron® 68 is a high-density liquid used to tamponade inferior retinal detachments. We present a case series of 12 patients treated with Densiron as an intraocular tamponade agent.Methods: A retrospective analysis of 12 eyes in 12 patients was carried out. The primary endpoint was anatomic reattachment of the retina following removal of Densiron oil.Results: All patients had inferior detachments; 33% had associated proliferative vitreoretinopathy (PVR. Densiron was utilized as a primary agent in five patients (42%; the remaining patients had prior unsuccessful surgery for retinal reattachment, including pars plana vitrectomy, cryotherapy, laser, encirclement, gas (C3F8 or C2F6, or silicone oil. Eleven patients (91% had successful reattachment of the retina at 3 months following removal of Densiron; one patient had extensive PVR, total retinal detachment, preretinal macula fibrosis, and chronic hypotony, and surgical intervention was unsuccessful. Six patients (50% had raised intraocular pressure (IOP, resolving in the majority of cases following Densiron removal; two patients had long-term raised IOP requiring topical or surgical therapy. Of the six phakic patients, 50% developed significant cataract in the operated eye. Of those with successful retinal reattachment, visual outcome was variable, with 36% patients gaining two to four lines on Snellen, 27% remaining objectively the same, and 36% losing one to two lines.Conclusion: The anatomic success rate is high (91% in patients requiring Densiron tamponade for inferior retinal detachments with or without evidence of PVR either as a primary or secondary intervention. A common complication is raised IOP; however, this most often resolves following removal of the oil.Keywords: intraocular tamponade, silicone oil, retinal detachment, retinal reattachments

  9. Effects of different levels of intraocular stray light on kinetic perimetry findings.

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    Full Text Available To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings.Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900 using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular stray light were induced using non-white opacity filter (WOF filters and WOFs applied to the clear plastic eye covers of the participants. The visual acuity, pupil diameter, isopter area, and kinetic sensitivity of each meridian were analyzed for each WOF density.Visual acuity deteriorated with increasing WOF densities (p < 0.01. With a visual acuity of 0.1 LogMAR units, the isopter areas for III4e, I4e, I3e, I2e, and I1e decreased by -32.7 degree2 (-0.2%, -255.7 degree2 (-2.6%, -381.2 degree2 (-6.2%, -314.8 degree2 (-12.8%, and -59.2 degree2 (-15.2%, respectively; kinetic sensitivity for those stimuli decreased by -0.1 degree (-0.1%, -0.8 degree (-1.4%, -1.6 degree (-3.7%, -2.7 degree (-9.7%, and -1.7 degree (-16.2%, respectively. The pupil diameter with each WOF density was not significantly different.Kinetic perimetry measurements with a high-intensity stimulus (i.e., III4e were unaffected by intraocular stray light. In contrast, measurements with the I4e, I3e, I2e, and I1e stimuli, especially I2e and I1e, were affected. Changes in the shape of the isopter resulting from opacity must be monitored, especially in cases of smaller and lower-intensity stimuli.

  10. Intraocular methotrexate can induce extended remission in some patients in noninfectious uveitis.

    Science.gov (United States)

    Taylor, Simon R J; Banker, Alay; Schlaen, Ariel; Couto, Cristobal; Matthe, Egbert; Joshi, Lavnish; Menezo, Victor; Nguyen, Ethan; Tomkins-Netzer, Oren; Bar, Asaf; Morarji, Jiten; McCluskey, Peter; Lightman, Sue

    2013-01-01

    To assess the outcomes of the intravitreal administration of methotrexate in uveitis. Multicenter, retrospective interventional case series of patients with noninfectious uveitis. Thirty-eight eyes of 30 patients were enrolled, including a total of 54 intravitreal injections of methotrexate at a dose of 400 µg in 0.1 mL. The primary outcome measure was visual acuity. Secondary outcome measures included control of intraocular inflammation and cystoid macular edema, time to relapse, development of adverse events, and levels of systemic corticosteroid and immunosuppressive therapy. Methotrexate proved effective in controlling intraocular inflammation and improving vision in 30 of 38 eyes (79%). The side effect profile was good, with no reported serious ocular adverse events and only one patient having an intraocular pressure of >21 mmHg. Of the 30 eyes that responded to treatment, 8 relapsed, but 22 (73%) entered an extended period of remission, with the Kaplan-Meier estimate of median time to relapse for the whole group being 17 months. The eight eyes that relapsed were reinjected and all responded to treatment. One eye relapsed at 3 months, but 7 eyes again entered extended remission. Of the 14 patients on systemic therapy at the start of the study, 8 (57%) were able to significantly reduce this following intravitreal methotrexate injection. In patients with uveitis and uveitic cystoid macular edema, intravitreal MTX can effectively improve visual acuity and reduce cystoid macular edema and, in some patients, allows the reduction of immunosuppressive therapy. Some patients relapse at 3 to 4 months, but a large proportion (73%) enter an extended period of remission of up to 18 months. This larger study extends the results obtained from previous smaller studies suggesting the viability of intravitreal methotrexate as a treatment option in uveitis.

  11. Implantation of iris-claw Artisan intraocular lens for aphakia in Fuchs′ heterochromic iridocyclitis

    Directory of Open Access Journals (Sweden)

    Ahmad Kheirkhah

    2014-01-01

    Full Text Available Implantation of iris-claw Artisan intraocular lens (IOL is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs′ heterochromic iridocyclitis (FHI due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphakia with no capsular support due to a previous complicated cataract surgery. Enclavation was easily performed and no intraoperative complication was noted. Postoperative course was uneventful with no significant anterior chamber inflammation during 12 months of follow-up. Although there were few deposits on the IOL surface, the patient achieved a best-corrected visual acuity of 20/20 without developing glaucoma or other complications. Therefore, Artisan IOL may be considered for correction of aphakia in patients with FHI. However, studies on large number of patients are required to evaluate safety of the procedure.

  12. Intraocular lens opacification after Descemet's stripping automated endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Meng-Sheng Lee

    2017-01-01

    Full Text Available Compared with conventional penetrating keratoplasty, Descemet's stripping automated endothelial keratoplasty (DSAEK more effectively maintain global integrity and rapid vision rehabilitation with less ocular surface disorders in patients with endothelial dysfunction. Here, we report a case of a 76-year-old woman who experienced opacification of a hydrophilic intraocular lens (IOL approximately 10 months after DSAEK. The patient with no history of systemic disease developed pseudophakic bullous keratopathy in the right eye 2 years after undergoing cataract surgery. The best-corrected visual acuity (BCVA of the right eye was Snellen 0.01 when presented to our hospital. DSAEK was arranged and performed smoothly. However, the graft detached over the upper part of the cornea on postoperative day 1. Thus, rebubbling was performed immediately. After the procedure, the graft was well attached, and the cornea became clear gradually. The BCVA returned to Snellen 0.6. However, progressive opacification over the anterior surface of the IOL was observed 10 months postoperatively. Vision deteriorated to 0.5 with various refractive errors during 2-year follow-up. IOL exchange may be considered if the vision is getting worse. IOL opacification may result from a direct contact between the IOL surface and exogenous air, particularly in a hydrophilic IOL, and can be a rare but significant complication after DSAEK. Clinicians planning to perform DSAEK should consider the composition of the IOL, the amount of intracameral air, duration of air filling, and high intraocular pressure.

  13. Brachytherapy with cobalt plaques in the conservative treatment of intraocular tumors. The hospital A.C. camargo experience

    International Nuclear Information System (INIS)

    Trippe, N.; Novaes, P.E.R.S.; Ferrigno, R.; Pellizzon, A.C.; Fogarolli, R.C.; Maia, M.A.C.; Salvajoli, J.V.; Baraldi, H.E.; Chojniak, M.M.; Erwene, CM

    1996-01-01

    From December 1989 to December 1993, 76 cases of intraocular tumors, including 56 adult patients with uveal melanomas and 20 children with retinoblastoma, were treated with exclusive intraocular brachytherapy with Cobalt plaques. The goal was to keep the vision function and at same time not compromising the chance of cure. The dose prescribed was 40Gy, calculated at the apex of the lesion for retinoblastomas and 100 to 120Gy for uveal melanomas. With the minimum follow up of 24 months, of the 56 patients with uveal melanomas, 41 (73,3%) had their vision preserved and 15 (26,4%) had local failure and were underwent enucleation. With the medium follow up of 27 months, 17 (85,5%) of the patients with retinoblastoma had their vision preserved, while 3 (15%) had local failure and were treated by enucleation. The grade I and II complications occurred in 9 (42,8%) patients and 100% of them are with no evidence of systemic disease. When well indicated, the conservative treatment of intraocular tumors with brachytherapy is a good alternative to enucleation and must be done by a multidisciplinary and well trained medical professional group

  14. CD5-Positive Primary Intraocular B-Cell Lymphoma Arising during Methotrexate and Tumor Necrosis Factor Inhibitor Treatment

    Directory of Open Access Journals (Sweden)

    Kenji Nagata

    2015-09-01

    Full Text Available Purpose: To report a case of CD5+ primary intraocular B-cell lymphoma arising during methotrexate (MTX and tumor necrosis factor (TNF inhibitor treatment in a young patient with rheumatoid arthritis and uveitis. Case Presentation: A 39-year-old woman treated with MTX and a TNF inhibitor for rheumatoid arthritis and uveitis had steroid-resistant vitreous opacity. A vitreous sample was obtained by using diagnostic vitrectomy and was categorized as class V based on cytologic examination. Flow cytometric analysis of the vitreous sample revealed that abnormal cells were CD5+, CD10-, CD19+, CD20+ and immunoglobulin light-chain kappa+, suggesting the diagnosis of CD5+ primary intraocular B-cell lymphoma. Polymerase chain reaction (PCR detected immunoglobulin heavy-chain gene rearrangement. Epstein-Barr virus (EBV DNA was detected in the vitreous sample by using PCR, and immunohistochemistry revealed EBV latent membrane protein-1 expression in the abnormal cells infiltrating the vitreous. Optic nerve invasion was observed on magnetic resonance imaging. Conclusion: Primary intraocular lymphoma (PIOL may develop in patients receiving MTX and TNF inhibitor treatment. EBV infection may play an important role in the pathogenesis of PIOL arising during immunosuppressive therapy.

  15. Genome-wide association study of intraocular pressure identifies the GLCCI1/ICA1 region as a glaucoma susceptibility locus

    OpenAIRE

    Strange, Amy; Bellenguez, Céline; Sim, Xueling; Luben, Robert; Hysi, Pirro G.; Ramdas, Wishal D.; van Koolwijk, Leonieke M.E.; Freeman, Colin; Pirinen, Matti; Su, Zhan; Band, Gavin; Pearson, Richard; Vukcevic, Damjan; Langford, Cordelia; Deloukas, Panos

    2013-01-01

    To discover quantitative trait loci for intraocular pressure, a major risk factor for glaucoma and the only modifiable one, we performed a genome-wide association study on a discovery cohort of 2175 individuals from Sydney, Australia. We found a novel association between intraocular pressure and a common variant at 7p21 near to GLCCI1 and ICA1. The findings in this region were confirmed through two UK replication cohorts totalling 4866 individuals (rs59072263, P(combined) = 1.10 × 10(-8)). A ...

  16. Phacoemulsification with intraocular lens implantation in primary angle-closure suspect, primary angle-closure and primary angle-closure glaucoma with cataract

    Directory of Open Access Journals (Sweden)

    Kun Zeng

    2013-08-01

    Full Text Available AIM: To evaluate the features and clinical outcomes of cataract extraction by phacoemulsification with intraocular lens implantation in primary angle-closure suspect(PACS, primary angle-closure(PACand primary angle-closure glaucoma(PACGwith cataract.METHODS:Phacoemulsification with intraocular lens implantation was performed on 86 cases(86 eyesdiagnosed as PACS, PAC and PACG co-existing cataract from January to December 2012. All cases were followed up for 3 months to 1 year. Pre-operative and post-operative visual acuity, intraocular pressure(IOP, gonioscopy, ultrasound biomicroscopy(UBM, visual field and usage of anti-glaucomaous eye drops were recorded.RESULTS:Zonular dialysis existed in 19 eyes(22%. The post-operative visual acuity improved in 84 eyes(98%. The post-operative visual acuity was CONCLUSION: PACS, PAC and PACG co-existing zonular dialysis is common. Phacoemulsification with IOL implantation can reduce IOP, deepen anterior chamber and open angle.

  17. Implante intra-ocular de lentes dobráveis "piggyback" em paciente portador de catarata congênita no primeiro ano de vida: relato de caso Piggyback foldable intraocular lens implant in patient with congenital cataract in the first year of life: case report

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2004-12-01

    Full Text Available No presente relato os autores descrevem um caso de catarata congênita unilateral tratada cirurgicamente com implante intra-ocular de lentes dobráveis "piggyback", ainda não descrito na literatura nacional. São analisadas as diferenças e semelhanças com outros casos descritos na literatura.The authors report a case of congenital cataract, which was treated with piggyback foldable intraocular lens implant, not described in the Brazilian literature. The differences and similarities are analyzed with other reported cases in the literature.

  18. Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs.

    Science.gov (United States)

    Ramón, María L; Piñero, David P; Pérez-Cambrodí, Rafael J

    2012-02-01

    To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit. Copyright 2012, SLACK Incorporated.

  19. [Possibility of 3D Printing in Ophthalmology - First Experiences by Stereotactic Radiosurgery Planning Scheme of Intraocular Tumor].

    Science.gov (United States)

    Furdová, A; Furdová, Ad; Thurzo, A; Šramka, M; Chorvát, M; Králik, G

    Nowadays 3D printing allows us to create physical objects on the basis of digital data. Thanks to its rapid development the use enormously increased in medicine too. Its creations facilitate surgical planning processes, education and research in context of organ transplantation, individualization prostheses, breast forms, and others.Our article describes the wide range of applied 3D printing technology possibilities in ophthalmology. It is focusing on innovative implementation of eye tumors treatment planning in stereotactic radiosurgery irradiation.We analyze our first experience with 3D printing model of the eye in intraocular tumor planning stereotactic radiosurgery. 3D printing, model, Fused Deposition Modelling, stereotactic radiosurgery, prostheses, intraocular tumor.

  20. The effect of increased intra-abdominal pressure on orbital subarachnoid space width and intraocular pressure.

    Science.gov (United States)

    Liu, Su-Meng; Wang, Ning-Li; Zuo, Zhen-Tao; Chen, Wei-Wei; Yang, Di-Ya; Li, Zhen; Cao, Yi-Wen

    2018-02-01

    In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can relieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 ± 0.1 mm (range: 0.77-1.05 mm), 0.77 ± 0.11 mm (range: 0.60-0.94 mm), 0.70 ± 0.08 mm (range: 0.62-0.80 mm), and 0.68 ± 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the

  1. UV laser ablation of intraocular lenses: SEM and AFM microscopy examination of the biomaterial surface

    International Nuclear Information System (INIS)

    Spyratou, E.; Asproudis, I.; Tsoutsi, D.; Bacharis, C.; Moutsouris, K.; Makropoulou, M.; Serafetinides, A.A.

    2010-01-01

    Several new materials and patterns are studied for the formation and etching of intraocular lenses (IOLs), in order to improve their optical properties, to reduce the diffractive aberrations and to decrease the incidence of posterior capsular opacification. The aim of this study is to investigate the use of UV (λ = 266 nm) laser pulses to ablate the intraocular lenses materials, and thus to provide an alternative to conventional surface shaping techniques for IOLs fabrication. Ablation experiments were conducted using various polymer substrates of hydrophobic acrylic IOLs and PMMA IOLs. We investigated the ablation efficiency and the morphology of the ablated area by imaging the surface modification with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The morphological appearance of IOL samples reveals the effect of a photochemical and photothermal ablation mechanism.

  2. UV laser ablation of intraocular lenses: SEM and AFM microscopy examination of the biomaterial surface

    Energy Technology Data Exchange (ETDEWEB)

    Spyratou, E., E-mail: ellas5@central.ntua.gr [National Technical University of Athens, School of Applied Mathematical and Physical Sciences, Department of Physics, Zografou Campus, Athens, 15780 (Greece); Asproudis, I. [Department of Ophthalmology, University Hospital of Ioannina, Ioannina, 45110 (Greece); Tsoutsi, D. [Department of Chemistry, University of Ioannina, Ioannina, 45110 (Greece); Bacharis, C.; Moutsouris, K.; Makropoulou, M.; Serafetinides, A.A. [National Technical University of Athens, School of Applied Mathematical and Physical Sciences, Department of Physics, Zografou Campus, Athens, 15780 (Greece)

    2010-02-01

    Several new materials and patterns are studied for the formation and etching of intraocular lenses (IOLs), in order to improve their optical properties, to reduce the diffractive aberrations and to decrease the incidence of posterior capsular opacification. The aim of this study is to investigate the use of UV ({lambda} = 266 nm) laser pulses to ablate the intraocular lenses materials, and thus to provide an alternative to conventional surface shaping techniques for IOLs fabrication. Ablation experiments were conducted using various polymer substrates of hydrophobic acrylic IOLs and PMMA IOLs. We investigated the ablation efficiency and the morphology of the ablated area by imaging the surface modification with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The morphological appearance of IOL samples reveals the effect of a photochemical and photothermal ablation mechanism.

  3. Iris-claw intraocular lenses to correct aphakia in the absence of capsule support.

    Science.gov (United States)

    De Silva, Samantha R; Arun, Kikkeri; Anandan, Maghizh; Glover, Nicholas; Patel, Chetan K; Rosen, Paul

    2011-09-01

    To evaluate the indications, postoperative visual efficacy, and complication rate after intraocular implantation of an iris-claw aphakic intraocular lens (IOL). Oxford Eye Hospital, Oxford, United Kingdom. Case series. This chart review comprised eyes with no capsule support that had anterior iris-fixation IOL implantation for aphakia between 2001 and 2009. The study comprised 116 eyes (104 patients). Iris-claw IOLs were inserted during primary lens surgery in 18 eyes (15.5%), during an IOL exchange procedure for dislocated posterior chamber IOLs in 19 eyes (16.4%), and as a secondary procedure in 79 eyes (68.1%). The mean follow-up was 22.4 months (range 3 to 79 months). The final corrected distance visual acuity (CDVA) was 6/12 or better in 68.9% of all eyes and in 47 of 53 eyes (88.7%) with no preoperative comorbidity. Complications included wound leak requiring resuturing in 2.6% of eyes, postoperative intraocular pressure rise in 9.5% of eyes (glaucoma escalation 0.8%), and cystoid macular edema in 7.7% of eyes (0.8% chronic). Iris-claw IOL subluxation occurred in 6.0% of eyes from 5 days to 60 months postoperatively; all the IOLs were repositioned. Corneal decompensation occurred in 1.7% of eyes; 0.8% had retinal detachments. Iris-claw IOL implantation for aphakia gave a good visual outcome and can be used for a wide range of indications. Postoperative complication rates were comparable to, if not better than, those with conventional anterior chamber IOLs. Correct implantation technique is critical in avoiding postoperative IOL subluxation. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Aderência bacteriana in vitro a lentes intra-oculares de polimetilmetacrilato e de silicone In vitro bacterial adherence to silicone and polymetylmethacrylate intraocular lenses

    Directory of Open Access Journals (Sweden)

    Claudete Inês Locatelli

    2004-04-01

    Full Text Available OBJETIVOS: Verificar a aderência bacteriana a lentes intra-oculares de silicone e de polimetilmetacrilato como possível fator de risco no desenvolvimento de endoftalmite pós-operatória, utilizando-se um modelo in vitro com três microrganismos potencialmente patogênicos. MÉTODOS: As análises foram realizadas com cepas de Staphylococcus aureus ATCC 29213, Staphylococcus epidermidis (amostra clínica e Pseudomonas aeruginosa ATCC 27853 incluindo a determinação de curvas de crescimento, testes para verificação de produção de cápsula, avaliação da hidrofobicidade, testes de aderência a diferentes materiais, microscopia óptica, microscopia eletrônica de varredura e microscopia de força atômica. RESULTADOS: A produção de cápsula e a aderência das três diferentes cepas não mostraram qualquer relação com a quantidade de microrganismos; em relação às lentes intra-oculares de polimetilmetacrilato e de silicone, não houve diferença estatisticamente significativa na aderência de S. aureus e S. epidermidis; P. aeruginosa foi o microrganismo mais aderente a ambos os materiais. A microscopia eletrônica de varredura confirmou estes achados em relação à aderência, ao peso que a microscopia de força atômica evidenciou a produção de biofilme pelas cepas de S. aureus, S. epidermidis e P. aeruginosa. CONCLUSÕES: Constatou-se, in vitro, que os materiais analisados não diferiram com relação à taxa de aderência bacteriana, porém, P. aeruginosa apresentou maior eficiência de adesão entre as bactérias testadas. Todas as cepas produziram biofilme. Silicone foi o material mais hidrofóbico, quando comparado ao polimetilmetacrilato.PURPOSE: To evaluate bacterial adherence to silicone and polymetylmethacrylate (PMMA intraocular lenses as a risk factor for postsurgery endophthalmitis by using an in vitro model with three potentially pathogenic microorganisms. METHODS: In vitro experiments were carried out with the

  5. Vitrectomía pars plana y reimplante de lente intraocular en surco Pars plana vitrectomy and intraocular lens repositioning in the sulcus

    Directory of Open Access Journals (Sweden)

    Alejandro Guerra García

    2010-01-01

    Full Text Available Se presentó un caso de lente intraocular luxado a vítreo en paciente con conteo bajo de células endoteliales e intolerancia a lentes de contacto. Se practicó vitrectomía pars plana con reimplante de lente en surco ciliar con el objetivo de demostrar la fiabilidad de la técnica para casos que presenten condiciones adecuadas y situaciones especiales. Se revisó la bibliografía para conocer las tendencias actuales con respecto al manejo de esta patología. El paciente alcanzó una agudeza visual de 20/30. El lente permaneció estable en el surco 3 meses después de practicada la vitrectomía. El manejo de esta entidad debe ser personalizado. La técnica utilizada debe ser siempre la primera opción de tratamiento y parece ser segura en casos cuidadosamente escogidos.A case of dislocated intraocular lens moved to the vitreous cavity in a patient with low endothelial cell count and contact lens intolerance was reported. A pars plana vitrectomy with lens repositioning was performed to demonstrate the safety of this technique for some special cases under adequate conditions. The literature was reviewed to learn about the current management of this pathology. Finally, patient's best visual acuity was 20/30. The stability of the lens was confirmed three month l after the vitrectomy. Management of this disorder should be customized. This technique should be considered as the first option of treatment and seems to be safe in selected cases.

  6. Procedimiento para elaborar una lente intraocular monofocal asférica isoplanática y lente obtenida empleando dicho procedimiento

    OpenAIRE

    Barbero, Sergio; Marcos, Susana; Dorronsoro, Carlos; Montejo, Javier; Salazar Salegui, Pedro

    2010-01-01

    Procedimiento para elaborar una lente intraocular monofocal asférica isoplanática y lente obtenida empleando dicho procedimiento. Permite obtener lentes oftálmicas monofocales asféricas isoplanáticas en un rango visual de hasta 25º (preferentemente hasta 10º) de amplitud. El procedimiento comprende las etapas de: 1.- Definición matemática de un modelo de ojo afáquico; 2.- Definición matemática de un modelo de lente intraocular; 3.- Definición matemática de la implantac...

  7. Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea.

    Science.gov (United States)

    Clement, Colin I; Parker, Douglas G A; Goldberg, Ivan

    2016-01-01

    Accurate measurement of intra-ocular pressure is a fundamental component of the ocular examination. The most common method of measuring IOP is by Goldmann applanation tonometry, the accuracy of which is influenced by the thickness and biomechanical properties of the cornea. Algorithms devised to correct for corneal thickness to estimate IOP oversimplify the effects of corneal biomechanics. The viscous and elastic properties of the cornea influence IOP measurements in unpredictable ways, a finding borne out in studies of patients with inherently abnormal and surgically altered corneal biomechanics. Dynamic contour tonometry, rebound tonometry and the ocular response analyzer provide useful alternatives to GAT in patients with abnormal corneas, such as those who have undergone laser vision correction or keratoplasty. This article reviews the various methods of intra-ocular pressure measurement available to the clinician and the ways in which their utility is influenced by variations in corneal thickness and biomechanics.

  8. Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.

    Science.gov (United States)

    Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo

    2015-05-01

    Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.

  9. Effect of pegaptanib sodium 0.3 mg intravitreal injections (Macugen) in intraocular pressure

    DEFF Research Database (Denmark)

    Boyer, David S; Goldbaum, Mauro; Leys, Anita M

    2014-01-01

    OBJECTIVE: To assess the rate of pegaptanib-associated sustained intraocular pressure (IOP) elevation. METHODS: A posthoc analysis was conducted on all IOP measurements, except the immediate 30-min postinjection, from all subjects randomised to pegaptanib 0.3 mg or sham injections continuously in...

  10. Sutureless intrascleral intraocular lens fixation with lamellar dissection of scleral tunnel

    Directory of Open Access Journals (Sweden)

    Kawaji T

    2016-01-01

    Full Text Available Takahiro Kawaji,1,2 Tomoki Sato,2 Hidenobu Tanihara11Department of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Chuo-ku, 2Sato Eye & Internal Medicine Clinic, Kumamoto, JapanPurpose: To report the results of sutureless scleral fixation of a posterior chamber intraocular lens (IOL by using our developed simple technique.Methods: We retrospectively reviewed the medical records of 48 eyes of 47 patients who underwent sutureless intrascleral IOL fixation by using our modified technique. A 25-gauge microvitreoretinal knife was used to perform sclerotomies and create limbus-parallel scleral tunnels with lamellar dissection in which the haptics were fixed.Results: The IOLs were fixed and centered well. The mean follow-up period was 26.7 months. Postoperative complications included smooth vitreous hemorrhage in four eyes (8.3%, cystoid macular edema in two eyes (4.2%, and iris capture of the IOL in two eyes (4.2%. No other complications, such as breakage of the IOL, spontaneous IOL dislocation, or retinal detachment, were detected during the follow-up period.Conclusion: The lamellar dissection of the limbus-parallel scleral tunnel can simplify the forceps-assisted introduction of the haptics into the scleral tunnel, and this technique seemed to be safe.Keywords: intraocular lenses, ophthalmologic surgical procedures, intrascleral fixation, sutureless fixation

  11. Opacification of hydrophilic intraocular lenses after Descemet stripping automated endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Morgan-Warren PJ

    2015-02-01

    Full Text Available Peter J Morgan-Warren, Walter Andreatta, Amit K Patel Department of Ophthalmology, Solihull Hospital, Heart of England NHS Foundation Trust, Birmingham, UK Purpose: Opacification of hydrophilic acrylic intraocular lenses (IOLs is an emerging complication following Descemet stripping automated endothelial keratoplasty (DSAEK. We report six cases and review the current literature.Methods: In this retrospective, noncomparative, observational case series, patients with IOL opacification after previous DSAEK surgery were identified from corneal clinic records. Case notes were reviewed for demographic details, indication for DSAEK, IOL model, incidence of rebubbling, and postoperative course.Results: Six patients developed IOL opacification after DSAEK. All patients had Fuchs’ endothelial dystrophy and had previously received hydrophilic acrylic IOL models. Central anterior IOL opacification was noted in all six cases. Five cases (83% had required rebubbling due to dislocated graft tissue, and one had an early postoperative intraocular pressure (IOP rise. Five cases (83% were managed conservatively, and one case with a failed graft underwent redo DSAEK and IOL exchange.Conclusion: Repeated exposure to intracameral air, raised IOP, and other patient influences may be major etiological factors for IOL opacification after DSAEK. We advise avoiding hydrophilic acrylic IOL models in patients who may require future endothelial keratoplasty. Keywords: IOL, DSAEK, lamellar keratoplasty, endothelial corneal transplantation

  12. Prótese intra-ocular de resina acrílica em cães e gatos Acrylic resin intraocular prosthesis in dogs and cats

    Directory of Open Access Journals (Sweden)

    S.C. Rahal

    2000-08-01

    Full Text Available Foram atendidos no Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Unesp - Campus de Botucatu, 11 animais (oito cães e três gatos, com alterações oftálmicas unilaterais graves que levaram à perda total da função ocular (protrusão de globo com injúria nervosa e estrutural, perfurações de córnea com perda de conteúdo intra-ocular e endoftalmites, entre outras. Os animais, com idades entre dois meses e 10 anos, foram submetidos à evisceração e posterior inclusão de esfera de resina acrílica (metilmetacrilato na capa córneo-escleral ou escleral. As esferas foram previamente confeccionadas e esterilizadas por autoclavagem. No pós-operatório foram utilizados antiinflamatórios e antibioticoterapia tópica combinada ou não a sistêmica. O período de observação variou de 2 meses a 3 anos e os aspectos avaliados foram secreção ocular, blefarospasmo, sinais de desconforto e estética. Obtiveram-se resultados satisfatórios em oito casos. Concluiu-se que a resina acrílica pode ser uma alternativa para uso como inclusão em cavidade anoftálmica.Eleven animals (eight dogs and three cats, aged between two months and ten years were referred to the Veterinary Hospital of Faculty of Veterinary Medicine and Animal Science - Unesp, Botucatu, Brazil. These animals presented severe unilateral ophthalmic changes that lead to a total loss of ocular function, such as prolapsed eyes with nervous and structural injury, corneal damage with loss of intraocular contents or endophthalmitis among others. They were submitted to evisceration followed by the insertion of an acrylic resin prosthesis (methylmethacrylate in the corneoscleral or scleral shell. The spheres were previously made and sterilized by autoclave. The postoperative medical therapy included topical and systemic broad-spectrum antibiotics for seven days and anti-inflammatory drugs. The follow-up time varied from two months to three years. The evaluated

  13. Reverse pupillary block associated with pigment dispersion syndrome after in-the-bag intraocular lens implantation.

    Science.gov (United States)

    Itagaki, Hideo; Kunikata, Toshio; Hiratsuka, Kentaro; Saito, Junichiro; Oshika, Tetsuro

    2013-12-01

    A 61-year-old man with high myopia who had received a systemic α1A-adrenoceptor antagonist had phacoemulsification and in-the-bag intraocular lens implantation in the right eye. One day postoperatively, marked pigment dispersion in the anterior chamber, posterior bowing of the iris, and iridodonesis were noted associated with a subsequent elevation in intraocular pressure (IOP). Pharmacological pupil dilation was effective in reducing pigment dispersion and IOP, and laser peripheral iridotomy was performed to alleviate posterior bowing of the iris. We hypothesize that dynamic changes in the aqueous humor flow by cataract surgery and latent flaccidity of the iris due to the systemic α1A-adrenoceptor antagonist caused reverse pupillary block. High myopia may be another risk factor for this complication. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Influence of blue light spectrum filter on short-wavelength and standard automated perimetries Influência de filtro para o espectro azul da luz na perimetria computadorizada branco-branco e azul-amarelo

    Directory of Open Access Journals (Sweden)

    Leonardo Cunha Castro

    2006-10-01

    Full Text Available PURPOSE: To evaluate the influence of a blue light spectrum filter (BLSF, similar in light spectrum transmittance to the intraocular lens Acrysof NaturalTM, on standard automated perimetry (SAP and short-wavelength automated perimetry (SWAP. METHODS: Twenty young individuals (OBJETIVO: Avaliar a influência de um filtro para o espectro azul da luz, semelhante à lente intra-ocular Acrysof Natural®, nos exames de perimetria automatizada padrão (branco-no-branco e de comprimento de onda curto (azul-no-amarelo. MÉTODOS: Vinte pacientes jovens sem alterações oculares (20 olhos realizaram seqüência de 4 exames de campo visual: perimetria automatizada padrão e azul-no-amarelo com e sem o filtro para o espectro azul da luz. Os índices de limiar foveal (FT, desvio médio (MD e desvio-padrão (PSD obtidos em todos os exames e a diferença causada pela excentricidade nos exames de perimetria automatizada azul-no-amarelo foram analisados. Variabilidade interindivíduos (desvio-padrão dos pontos testados foi calculada. RESULTADOS: Observou-se redução estatisticamente significante no desvio médio (p<0.001 e no limiar foveal (p<0.001 medidos pela perimetria automatizada azul-no-amarelo com o uso do filtro para o espectro azul da luz comparado quando realizado sem o filtro. Nenhum outro índice avaliado apresentou diferença estatisticamente significante nos exames de perimetria automatizada padrão ou azul-no-amarelo. Foi notado aumento da variabilidade interindivíduos com a excentricidade nos exames de perimetria automatizada azul-no-amarelo com e sem o uso do filtro para o espectro azul da luz, assim como a diferença de sensibilidade entre os hemisférios inferior e superior (hemisfério inferior menos superior, mas não houve diferença estatisticamente significante quando comparados os exames com e sem o uso do filtro. Quando foram comparados os 4 pontos mais inferiores e os 4 pontos mais superiores, a diferença inferior-superior aumentou

  15. Implante de lente intraocular trifocal difractivo: análisis y resultado de la agudeza visual

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Ibáñez-Hernández

    2017-09-01

    Conclusiones: El implante de un lente intraocular trifocal difractivo es capaz de proporcionar una excelente visión lejana, intermedia y cercana, con escasas aberraciones ópticas, permitiendo una mejor calidad visual útil en actividades desarrolladas a diferentes distancias.

  16. Facoemulsificação, vitrectomia via pars plana e implante de lente intra-ocular em olhos com retinopatia diabética proliferativa Phacoemulsification, pars plana vitrectomy and intraocular lens implant in eyes with proliferative diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Armando Belfort Mattos

    2004-06-01

    Full Text Available OBJETIVO: Avaliar a viabilidade da técnica de facoemulsificação para a extração da catarata com implante de lente intra-ocular combinada à vitrectomia via pars plana em olhos com retinopatia diabética proliferativa, em um único procedimento cirúrgico. MÉTODOS: Foram revisados os prontuários de 47 pacientes (53 olhos com retinopatia diabética proliferativa e catarata que foram submetidos ao procedimento combinado de vitrectomia via pars plana, facoemulsificação e implante de lente intra-ocular no mesmo ato cirúrgico, entre janeiro de 1991 e setembro de 1998 no Bascom Palmer Eye Institute, hospital de olhos filiado à Universidade de Miami. O estudo foi realizado em conjunto com a Universidade Federal de São Paulo. Participaram do estudo 43 olhos de 40 pacientes. RESULTADOS: O tempo de seguimento variou de três a 60 meses com média de 20 meses. A idade dos pacientes variou de 37 a 77 anos com média de 59 anos. A acuidade visual melhorou duas linhas ou mais em relação ao pré-operatório em 26 (60,4% olhos, permaneceu a mesma em 9 (20,9% e piorou em 8 (18,6%. Em (23,2% 10 olhos a acuidade visual aumentou para 20/40. O teste estatístico chamado de "teste do sinal" mostrou-se estatisticamente significante na melhora da acuidade visual final. A complicação mais observada foi a hemorragia vítrea recorrente, ocorrendo em 12 (27,9% olhos, seguida pela inflamação transitória da câmara anterior em 9 olhos (20,9%. Complicações intra-operatórias relacionadas à extração do cristalino foram raras. No pós-operatório observaram-se captura da lente intra-ocular em 2 (4,6 % olhos e lente intra-ocular subluxada em 1 (2,3% olho. CONCLUSÕES: A cirurgia combinada de facoemulsificação, implante de lente intra-ocular e vitrectomia via pars plana em olhos com retinopatia diabética é procedimento bem tolerado e geralmente apresenta bons resultados com relação à acuidade visual. Um único procedimento para remover a catarata e

  17. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  18. Effect of gamma radiation on the optical properties of intraocular lenses

    International Nuclear Information System (INIS)

    Naguib, N.I.

    2006-01-01

    The effect of gamma rays in the range of doses up to 150 gray on optical and thermal properties of the intraocular lenses (IOL) made of polymethyl methacrylate (PMMA) was studied. Thermogravimetric analysis (TGA) and differential scanning colorimetry (DSC) have been performed to study the effect of gamma irradiation on the IOL. The results indicate that irradiation up to 150 Gy did not affect greatly the optical and thermal properties of the investigated IOL

  19. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  20. Facoemulsificación e implante de lente intraocular en cataratas causadas por uveitis Phacoemulsification and intraocular lens implantation in patients with cataract caused by uveitis

    Directory of Open Access Journals (Sweden)

    Dayamí Pérez Gómez

    2008-06-01

    Full Text Available OBJETIVO: Evaluar los resultados de la facoemulsificación y el implante de lente intraocular en cataratas causadas por uveítis. MÉTODOS: Se estudiaron 37 ojos con 6 meses de inactividad inflamatoria, agudeza visual menor de 0,6 y edad media de 47 años. Se excluyeron otras enfermedades que disminuyeran la visión. En el preoperatorio se prescribió antiinflamatorios. Se realizó la facoemulsificación con implante de lente intarocular (PMMA, óptica 6 mm; durante el seguimiento desde 24 h/6 meses se indicó antiinflamatorios esteroideos, no esteroideos e inmunosupresores hasta 6 semanas. RESULTADOS: Se observaron numerosas alteraciones del segmento anterior secundarias a las uveítis padecidas (posquirúrgicas, inespecíficas, ciclítis heterocrómica de Fuchs, postraumáticas, síndrome de Reiter, por toxoplasmosis y otras coroiditis infecciosas y por artritis reumatoide juvenil. No hubo recurrencia posquirúrgica de la uveítis en 9 ojos (24,3 %. Las complicaciones estuvieron relacionadas con la uveítis, la cirugía, la actividad inflamatoria, y la reacción del epitelio capsular. La opacidad capsular posterior apareció en 11 pacientes (29,7 % asociada a edad joven. La evolución individual se consideró satisfactoria en 30 (81,1 % pacientes con mejoría de la visión hasta 0,8-1,0 en 28 (75,6 % y 0,5-0,6 en 2 (5,4 %. CONCLUSIONES: La facoemulsificación con implante de lente intarocular es de gran utilidad en las cataratas posuveítis al condicionar poca agresión quirúrgica, ser controlable la inflamación y proporcionar buenos resultados visuales además del reordenamiento anatomofisiológico del segmento anterior.OBJECTIVE: To assess the results of phacoemulsification and intraocular lens implantation in cataracts caused by uveitis. METHODS: Thirty seven eyes with no inflammation for 6 months, visual acuity below 0.6 and average age of 47 years were studied. Other diseases affecting the vision were excluded. The preoperative

  1. Inflammatory and intraocular pressure outcomes after trabeculectomy in active uveitic glaucoma in Chinese

    Directory of Open Access Journals (Sweden)

    Doris W.F. Yick

    2015-06-01

    Full Text Available AIM: To analyze the outcomes in uveitic activity and intraocular pressure(IOPcontrol after trabeculectomy for uveitis with uncontrolled IOP. METHODS: The medical records of consecutive uveitic glaucoma patients undergoing trabeculectomy between October 2006 to March 2011 were retrospectively reviewed. Uveitic activity, frequency of recurrence, steroid dependence, and intraocular pressure control were compared with paired t-test before and after trabeculectomy. RESULTS: In 29 eyes from 29 patients, 90% of eyes were on topical steroids at the time of trabeculectomy. The mean age was 58.3±14.0 years old with a pre-operative IOP of 35.7±8.9mmHg. The mean follow up time was 35.2±18.7mo. There was a reduction of anterior chamber activity grading of 0.4±0.6(PPCONCLUSION: Uveitic activity and IOP control improved after trabeculectomy with a lower success rate to primary glaucomas. Trabeculectomy may be considered as a possible early intervention of active uveitis with high IOP for pressure and uveitic activity control.

  2. Effect of transscleral neodymium: YAG cyclophotocoagulation on intraocular lenses

    Energy Technology Data Exchange (ETDEWEB)

    Blomquist, P.H.; Gross, R.L.; Koch, D.D. (Baylor College of Medicine, Houston, TX (USA))

    1990-03-01

    A neodymium: YAG laser operating in the thermal mode was used to irradiate isolated intraocular lenses (IOLs) and to perform transscleral cyclophotocoagulation on pseudophakic autopsy eyes to investigate the potential damage to IOL haptics such irradiation may cause. In the isolated IOLs, 70 mJ of energy deformed and partially melted both polymethylmethacrylate (PMMA) and polypropylene haptics. One of the capsular-fixated PC-IOL haptics in an autopsy eye partially melted when irradiated with the maximum energy level (8.8 J), with the aiming beam focused 1 mm posterior to the limbus and maximal posterior focus offset.

  3. Early aggressive intraocular pressure lowering, target intraocular pressure, and a novel concept for glaucoma care.

    Science.gov (United States)

    Singh, Kuldev; Shrivastava, Anurag

    2008-11-01

    Early diagnosis of glaucomatous optic nerve damage offers the potential for early treatment which may prevent vision loss from this neurodegenerative disease. Even in patients who do not begin early treatment, early diagnosis allows for better monitoring of disease at a stage where the stakes are lower relative to later stages of the disease. For these reasons, early diagnosis of glaucomatous optic nerve disease is desirable and opens the door for appropriately aggressive therapy. The target intraocular pressure (IOP) concept is widely employed by glaucoma practitioners. Although there have been no randomized clinical trials or other high-quality studies showing the benefits of setting a target IOP versus not using this approach, there is ample evidence that lowering IOP slows glaucoma progression and, in general, lower is better, regardless of disease stage and baseline IOP level. We propose an alternative approach to managing glaucoma without the use of the target IOP concept and suggest that this market IOP concept should be compared with the target IOP approach in an appropriately powered comparative clinical trial.

  4. Black diaphragm intraocular lens implantation and penetrating keratoplasty in aphakic eyes with traumatic aniridia

    Directory of Open Access Journals (Sweden)

    Xiao-Guang Dong

    2013-04-01

    Full Text Available AIM: To evaluate the long-term outcome of implantation of black diaphragm intraocular (BDI lens combined with penetrating keratoplasty (PKP for managing aphakic eyes with traumatic aniridia and corneal damage. METHODS: Six aphakic eyes of six patients with traumatic aniridia and corneal damage had BDI lens implantation at Qingdao Eye Hospital, Shandong Eye Institute from June 2008 to November 2011. Medical records of the patients were reviewed. Three patients received PKP and after 12-18months were implanted with BDI lens. The other three patients completed PKP and BDI lens implantation at the same time. The corrected visual acuity, intraocular pressure and number of corneal endothelial cells were monitored. RESULTS: The patients were followed up for an average of 24.3±12.1months (range 14-48 months. All BDI lenses were located well. The best corrected visual acuity got improved in 5 patients (0.1-1.0 and decreased in 1 patient from 0.4 to 0.2. Three patients had normal intraocular pressure (IOP after implantation. Two patients required antiglaucoma medications to control IOP within the normal range and 1 patient implanted Ahmed glaucoma valve to control IOP. The corneal grafts kept transparent in all eyes and the corneal endothelial counting >1 000/mm2, although two patients experienced acute graft rejection and loss more than 30% corneal endothelial cells. CONCLUSION: Implantation of BDI lens combined with PKP is an effective option for managing aphakic eyes with traumatic aniridia and corneal damage. Although the results in our study are encouraging, additional studies of the long-term safety and efficacy are required. A larger study population and longer follow-up may be beneficial.

  5. Research on antibodies anti toxoplasma gondii in intraocular fluids (Aqueous and vitreous humor) from patients with ocular toxoplasmosis, in the City of Belém, Pará State

    OpenAIRE

    Carmo, Ediclei Lima do; Almeida, Edmundo Frota; Bichara, Cléa Nazaré; Póvoa, Marinete Marins

    2005-01-01

    Foi realizada pesquisa de anticorpos IgG, IgM e IgA anti-Toxoplasma gondii no soro e fluidos intra-oculares (humor aquoso e vítreo) de pacientes com toxoplasmose ocular. A partir dos resultados obtidos verificou-se que anticorpos IgG e IgA intraocular anti-Toxoplasma gondii podem vir a ser importantes marcadores no diagnóstico de toxoplasmose ocular.Tests were performed for antibodies IgG, IgM and IgA anti-Toxoplasma gondii antibodies in serum and intraocular fluids (Aqueous and vitreous humo...

  6. Visual acuity after trans-scleral sutured posterior chamber intraocular lens

    International Nuclear Information System (INIS)

    Mahmood, S.A.; Zafar, S.

    2014-01-01

    To determine the changes in visual acuity in patients undergoing Trans-Scleral Sutured Posterior Chamber Intra-Ocular Lens (TSSPCIOL) implantation at a tertiary care hospital in Karachi, Pakistan. Study Design: Case series. Place and Duration of Study: LRBT Tertiary Eye Hospital, Karachi, from January 2006 to December 2010. Methodology: Records of all patients undergoing implantation of TSSPCIOL were reviewed. Patients with diagnosed glaucoma, diabetic retinopathy, macular degeneration, history of recurrent uveitis, corneal haze or central corneal scars were excluded. For the final analysis, 70 eyes out of a total of 75 were selected. Main outcomes of interest were pre and postoperative visual acuities and surgical complications. SPSS 21 was used for data analysis. Results: Pre-operatively, the average Best Spectacle-Corrected Visual Acuity (BSCVA) was 6/36 on the Snellen chart. This improved to 6/12 postoperatively. The mean improvement seen was 2.4 lines on the Snellen chart (p < 0.05). Complications include transient intraocular pressure elevation in 25 eyes (36%), IOL tilt in 4 eyes (7.1%), Cystoid Macular Edema (CME) in 4 eyes (5.7%), vitreous haemorrhage in 2 eyes (2.9%), hyphema in 2 eyes (2.9%), uveitis in 1 eye (1.4%), and retinal detachment 1 eye (1.4%). No IOL subluxation, suture erosion, iris capture, choroidal effusion or endophthalmitis was encountered and no re-operations were needed. Conclusion: TSSPCIOLs are a good management option for patients with aphakia in whom PC IOLs cannot be placed. (author)

  7. Associação entre dois diferentes tipos de estrangulamento com a variação da pressão intraocular em atletas de jiu-jitsu

    OpenAIRE

    Scarpi,Marinho Jorge; Conte,Marcelo; Rossin,Reginaldo Alexandre; Skubs,Renato; Lenk,Rudolf Eberhard; Brant,Rodrigo

    2009-01-01

    OBJETIVO: Verificar a associação entre dois diferentes tipos de estrangulamento com a variação da pressão intraocular em atletas de jiu-jitsu. MÉTODO: Estudo observacional em grupo de 9 atletas de jiu-jitsu, com mínimo 6 meses de treinamento, sexo masculino, idades entre 20 e 30 anos, sem presença de lesões físicas e do bulbo ocular. Buscou-se associação entre a variação da pressão intraocular e os estrangulamentos Frontal da Guarda (E1) e Frontal da Montada (E2). A pressão intraocular foi de...

  8. Follow up of intraocular lens subluxation with a combined topographer/aberrometer

    OpenAIRE

    Georgios A. Kontadakis; George D. Kymionis; Vardhaman P. Kankariya; Ioannis G. Pallikaris

    2012-01-01

    Purpose: To report a 36-year-old patient with intraocular lens (IOL) subluxation that was followed for IOL stability with evaluation of images captured with the iTrace combined aberrometer/topographer. Methods: The patient had undergone phacoemulsification with IOL implantation for congenital cataract 15 years before. He presented with bilateral IOL subluxation, more severe in his right eye. Right eye was operated for IOL exchange and left eye was followed with the iTrace images. The image...

  9. Evaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting

    Directory of Open Access Journals (Sweden)

    Gonen Baser

    2016-12-01

    Full Text Available Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP, body weights, as well as systolic and diastolic blood pressures (SBP, DBP of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m. in the Ramadan of 2014 and two weeks after it. The data were analyzed using paired Student’s t-test and Pearson correlation analysis. Results: As the results demonstrated, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were 2.67±1.33 mmHg, 9.44±8.02 mmHg, 3.33±5.94 mmHg, and 0.90±0.46 kg during the fasting period, respectively. In addition, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were -0.33±1.4 mmHg (P=0.001, 0.55±7.25mmHg (P=0.003, -3.33±5.94 mmHg (P=0.001, and 0.12±0.45 kg (P=0.001 during the control period, respectively. There was a moderate correlation between the diurnal IOP and SBP differences (r=0.517, P=0.028. Conclusion: Based on the findings of the current study, the total fluid volume might have a more dominant effect on IOP peaks than the sympathetic system activity. Furthermore, the SBP was found to correlate with the IOP.

  10. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  11. Effect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with Cataract

    Directory of Open Access Journals (Sweden)

    Tansu Gönen

    2011-08-01

    Full Text Available Purpose: To evaluate the effect of preoperative anterior chamber depth (ACD on intraocular pressure (IOP after uneventful phacoemulsification and intraocular lens (IOL implantation in nonglaucomatous eyes. Material and Method: The medical records of fifty-five patients (30 male and 25 female were reviewed retrospectively. The patients who had undergone uneventful phacoemulsification and IOL implantation were divided into two groups according to the values of preoperative ACD: 30 eyes in group 1 (ACD≤3.27 mm and 25 eyes in group 2 (ACD>3.27 mm. IOP was measured using non-contact tonometer preoperatively and postoperatively (1 day, 1 week, 1 month, and 3 months. Results: Three months after phacoemulsification and IOL implantation, the mean IOP decreased 23.6% in group 1 and 13.7% in group 2. There was a statistically significant difference between the groups (p= 0.025. Discussion: The mean IOP decreases in eyes with shallow anterior chamber more than in normal eyes after uncomplicated phacoemulsification and IOL implantation. (Turk J Ophthalmol 2011; 41: 207-12

  12. Combining zonal refractive and diffractive aspheric multifocal intraocular lenses.

    Science.gov (United States)

    Muñoz, Gonzalo; Albarrán-Diego, César; Javaloy, Jaime; Sakla, Hani F; Cerviño, Alejandro

    2012-03-01

    To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH). This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire. Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients. The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction. Copyright 2012, SLACK Incorporated.

  13. Efficacy on chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Xiao-Ning Peng

    2014-04-01

    Full Text Available AIM: To study the clinical effects of chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation.METHODS:A total of 75 cases(80 eyes, in which loop-pad and chop knife were performed to chop nucleus before implanting intraocular lens. Visual acuity, postoperative astigmatism degree, intraoperative and postoperative complications were observed. The post-operative follow-up periods ranged from 3 to 12mo.RESULTS: The visual acuity was 0.3-0.5 in 37 eyes and 0.6 or better in 21 eyes at 1d, while was respectively in 43 eyes and in 26 eyes at 1mo. Compared with preoperative astigmatism(0.85±0.29D, there were significant difference at postoperative 1wk(1.75±0.55D(PP>0.05. Intraoperative posterior capsule rupture occurred in 4 eyes, which implantation was successful in 1 eye and 3 eyes was managed viaciliary sulcus. Two eyes had dermatoglyphic pattern edema in corneal endothelium which recovered after about 3d. Two eyes had local patchy opacities which recovered in 2wk. Two eyes had transient high intraocular pressure.CONCLUSION: The surgery is efficient, low cost, easy process and less complications, it is worth to be popularized.

  14. Chiron Vision files FDA application to market intraocular implant for CMV retinitis. Food and Drug Administration.

    Science.gov (United States)

    1995-07-01

    Chiron Corporation and Hoffman-LaRoche announced a filing of a New Drug Application with the Food and Drug Administration (FDA) to market Vitrasert, its intraocular implant which delivers ganciclovir directly to the eye for treatment of CMV retinitis. Clinical trials show that Vitrasert offers a clinical improvement versus intravenous ganciclovir in further delaying progression of CMV retinitis in the treated eye. One study reported that the median time to progression of CMV retinitis was 186 days for eyes receiving Vitrasert compared to 72 days for eyes receiving intravenous ganciclovir therapy. Chiron's intraocular implant contains ganciclovir embedded in a polymer-based system that slowly releases the drug into the eye for up to eight months. Two additional trials are underway. For further information contact the Professional Services Group at Chiron Corporation at (800) 244-7668, select 2.

  15. Intraocular Surgery in Kyphosis: An Easier Approach

    Directory of Open Access Journals (Sweden)

    Karanjit S. Kooner

    2013-06-01

    Full Text Available We describe a 49-year-old man with advanced kyphosis and dense cataract, who could only recline to about 40° from the vertical axis despite a maximal reverse Trendelenburg position and pillows under the head, neck, shoulders and knees. With a single corneal retraction suture at 6 o'clock, the eye could be rotated horizontally, which enabled the surgeon to perform a complex cataract surgery despite prior glaucoma shunt, posterior synechiae, a small pupil and the need to stain the capsule. As the eye can be brought into any desired position with a retraction suture, patients with kyphosis or other conditions that prevent them from assuming a supine position can still have safe intraocular procedures. This maneuver reduces the need to tilt patients to an uncomfortable position that may cause pain, increased breathing difficulty and elevated posterior vitreous pressure.

  16. Sectioning a luxated intraocular lens inside the vitreous cavity.

    Science.gov (United States)

    Vilaplana, Daniel; Pazos, Marta

    2013-07-01

    We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. [Scheimpflug photography for the examination of phakic intraocular lenses].

    Science.gov (United States)

    Baumeister, M

    2014-10-01

    High myopia phakic intraocular lenses (IOL) have become an established means of surgical correction for high ametropia. Scheimpflug photography is one of the methods which are frequently applied for postoperative examination of the implants. Results from published studies employing Scheimpflug photography for examination of anterior chamber angle-fixated, iris-fixated and sulcus-fixated phakic IOLs were evaluated. In several published studies Scheimpflug photography was used to examine the position of the implant and opacification of the crystalline lens. The results provided valuable evidence for the improvement of phakic IOL design. Scheimpflug photography offers an easy to use, rapid non-contact examination of phakic IOLs.

  18. Toric K3-fibred Calabi-Yau manifolds with del Pezzo divisors for string compactifications

    Energy Technology Data Exchange (ETDEWEB)

    Cicoli, Michele [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Mayrhofer, Christoph [Heidelberg Univ. (Germany). Inst. fuer Theoretische Physik; Kreuzer, Maximilian

    2011-06-15

    We analyse several explicit toric examples of compact K3-fibred Calabi-Yau three-folds which can be used for the study of string dualities and are crucial ingredients for the construction of LARGE Volume type IIB vacua with promising applications to cosmology and particle phenomenology. In order to build a phenomenologically viable model, on top of the two moduli corresponding to the base and the K3 fibre, we demand also the existence of two additional rigid divisors: the first supporting the non-perturbative effects needed to achieve moduli stabilisation, and the second allowing the presence of chiral matter on wrapped D-branes. We clarify the topology of these rigid divisors by discussing the interplay between a diagonal structure of the Calabi-Yau volume and D-terms. Del Pezzo divisors appearing in the volume form in a completely diagonal way are natural candidates for supporting non-perturbative effects and for quiver constructions, while 'non-diagonal' del Pezzo and rigid but not del Pezzo divisors are particularly interesting for model building in the geometric regime. Searching through the existing list of four dimensional reflexive lattice polytopes, we find 158 examples admitting a Calabi-Yau hypersurface which is a K3 fibration with four Kaehler moduli where at least one of them is a 'diagonal' del Pezzo. We work out explicitly the topological details of a few examples showing how, in the case of simplicial polytopes, all the del Pezzo divisors are 'diagonal', while 'non-diagonal' ones appear only in the case of non-simplicial polytopes. A companion paper will use these results in the study of moduli stabilisation for globally consistent explicit Calabi-Yau compactifications with the local presence of chirality. (orig.)

  19. Toric K3-fibred Calabi-Yau manifolds with del Pezzo divisors for string compactifications

    International Nuclear Information System (INIS)

    Cicoli, Michele; Mayrhofer, Christoph; Kreuzer, Maximilian

    2011-06-01

    We analyse several explicit toric examples of compact K3-fibred Calabi-Yau three-folds which can be used for the study of string dualities and are crucial ingredients for the construction of LARGE Volume type IIB vacua with promising applications to cosmology and particle phenomenology. In order to build a phenomenologically viable model, on top of the two moduli corresponding to the base and the K3 fibre, we demand also the existence of two additional rigid divisors: the first supporting the non-perturbative effects needed to achieve moduli stabilisation, and the second allowing the presence of chiral matter on wrapped D-branes. We clarify the topology of these rigid divisors by discussing the interplay between a diagonal structure of the Calabi-Yau volume and D-terms. Del Pezzo divisors appearing in the volume form in a completely diagonal way are natural candidates for supporting non-perturbative effects and for quiver constructions, while 'non-diagonal' del Pezzo and rigid but not del Pezzo divisors are particularly interesting for model building in the geometric regime. Searching through the existing list of four dimensional reflexive lattice polytopes, we find 158 examples admitting a Calabi-Yau hypersurface which is a K3 fibration with four Kaehler moduli where at least one of them is a 'diagonal' del Pezzo. We work out explicitly the topological details of a few examples showing how, in the case of simplicial polytopes, all the del Pezzo divisors are 'diagonal', while 'non-diagonal' ones appear only in the case of non-simplicial polytopes. A companion paper will use these results in the study of moduli stabilisation for globally consistent explicit Calabi-Yau compactifications with the local presence of chirality. (orig.)

  20. CLINICAL PRESENTATION OF LENS INDUCED GLAUCOMA: STUDY OF EPIDEMIOLOGY, DURATION OF SYMPTOMS, INTRAOCULAR PRESSURE AND VISUAL ACUITY

    Directory of Open Access Journals (Sweden)

    Venkataratnam

    2015-10-01

    Full Text Available BACKGROUND: Lens Induced Glaucoma is a common cause of ocular morbidity. OBJECTIVES: Our study was to know the Epidemiological factors, Duration of Symptoms, Visual Acuity and Intraocular Pressure in the clinical Presentation of Lens Induced Glaucoma. MATERIALS AND METHODS : This w as a tertiary hospital based prospective study in the department of Glaucoma, Sarojini Devi Eye Hospital and Regional Institute of Ophthalmology (RIO, Osmania Medical College, Hyderabad over a period from March 2015 to August 2015. 50 Patients clinically diagnosed as Lens Induced Glaucoma (LIG were studied with the data of Age, Sex, literacy, Laterality and Rural / Urban status with the duration of symptoms, Intraocular pressure and Visual Acuity. The data was analyzed by simple statistical methods. RESULT S: 50 patients, clinically diagnosed as Lens Induced Glaucoma (LIG were studied. Age group distribution was 1(2.0% in 40 - 50yrs, 13 ( 26.0% in >50 - 60yrs, 26(52.0% in >60 - 70yrs and 10(20.0% in > 70 yrs. Sex distribution was 23(46.0% of Males and 27(54.0% of Females. Urban / Rural status was 15(30.0% of Urban and 35(70.0% of Rural. Literacy status was 7(14.0% of Literate and 43(86.0% of Illiterate. Laterality was RE in 24(48.0% and LE in 26(52.0%. Duration of the presenting symptoms before re porting to the Hospital was 12.0% in 2wks. Intraocular pressure (IOP in mm of Hg showed no case (0.0% in 20 – 40, 27(54.0% in >40 - 60 and 5(10.0% >60 wit h the Mean IOP of 42.12 mm of Hg. Visual Acuity (VA was PL +ve in 24(48.0 and HM - 3/60. CONCLUSIONS: Increasing age, female gender, rural, illiterate, and delayed reporting to the hospital after the pre senting symptoms were the common risk factors with increased Intraocular pressure and poor visual acuity in the clinical presentation of Lens induced Glaucoma.

  1. MR imaging of intraocular hemorrhage

    International Nuclear Information System (INIS)

    Saint-Louis, L.A.; Weiss, R.; Ellsworth, R.; Chang, S.; Deck, M.D.F.

    1987-01-01

    The authors evaluated with MR imaging 11 globes (nine patients) with spontaneous or traumatic intraocular hemorrhage. Subretinal blood was present in eight. Intravitreal bleeding was associated in seven and three subchoroidal. The ages of the hemorrhages ranged from 1 day to 6 months. Six of the subretinal and two subchoroidal cases had clotted blood with different intensity on the short TE images but were markedly hypointense on long TR/long TE images. The intravitreal blood was hyperintense on all sequences except in one. All imaging was performed with .5 T, 256 matrix, and 4- and 7- mm section thickness. Because of the varied appearance of hemorrhages, the authors scanned and are scanning two rabbits with intravitreal blood in vivo. Parameters include: 3-mm sections, T1, PD, T2 scans in .3-T and 1.5-T imagers. Initial results for the first 2 days show no change in signal intensity (hyperintense on all sequences). The T1 images show a diminishing intensity up to 8 days, and T2 scans remained hyperintense. These results so far correlate with the patient findings. The authors present the clinical findings and experimental correlation

  2. Spectral properties of common intraocular lens (IOL) types

    Science.gov (United States)

    Milne, Peter J.; Chapon, Pascal F.; Hamaoui, Marie; Parel, Jean-Marie A.; Clayman, H.; Rol, Pascal O.

    1999-06-01

    Currently over 50 kinds of intraocular lenses (IOLs) are approved for patient use in the treatment of cataracts and ametropia. These lenses are manufactured from at least 2 kinds of silicones as well as several kinds of acrylic polymers including polyHEMA, Poly HOXEMA, a range of polymethacrylate and polyacrylate formulations. We sought to measure spectral transmission curves of a range of IOLS in the UV-visible and near IR spectral regions in order to better characterize their optical properties and to provide a baseline from which to assess their alteration following implantation over time. Consideration of how this may best be achieved are discussed. The variable ability of both explained IOLs and some samples from a range of manufacturers to block UV wavelengths is commented upon.

  3. MANAGEMENT OF RESIDUAL REFRACTIVE ERROR AFTER CATARACT PHACOEMULSIFICATION. PART 2. INTRAOCULAR APPROACHES

    Directory of Open Access Journals (Sweden)

    K. B. Pershin

    2017-01-01

    Full Text Available The review presents an  analysis  of the  literature  data  on  the  methods of surgical  correction of residual  refractive  error after cataract phacoemulsification. Keratorefractive and intraocular approaches are  considered in details.  A comparison of the  efficacy and  safet y  of different groups   of methods on  the  example  of comparative studies is given.  Historically earlier  keratorefractive methods (laser  vision correction with LASIK and  PRK techniques on intact  eyes,  LASIK after  implantation  of multifocal  IOLs and arcuate keratotomy  after  phaco  are  indicated  for  the  correction of astigmatic refractive  error and  a small  spherical refractive error. Intraocular methods, including the  replacement of the  IOL  and  «piggyback» IOLs implantation  are  used  to  correct a large spherical refractive error. The introduction  of new  technology, the  implantation  of light-adjustable  IOLs, will  expand  the  existing evidence  and provide greater predictabilit y and efficiency of the  method  of correction of residual  refractive error.

  4. Application of diffractive aspheric multifocal intraocular lens in the Uighur in phacoemulsification

    Directory of Open Access Journals (Sweden)

    Nuersimanguli·Mijiti

    2016-05-01

    Full Text Available AIM:To research the efficacy and safety of diffractive aspheric multifocal intraocular lens(MIOLin the Uighur in phacoemulsification to provide guidance for the clinical treatment of cataracts patients in Xinjiang region. METHODS:Two hundred and twenty-eight Uygur patients(280 eyesreceived phacoemulsification from April 2012 to March 2013 were randomly divided into multifocal group(106 cases with 146 eyesand monofocal group(122 cases with 134 eyes. Patients were followed up for 3mo. The intraocular pressure(IOP, uncorrected distance visual acuity, uncorrected near vision, best-corrected distance visual acuity and best corrected near vision were measured. The delensed rate, visual quality, and satisfaction for lenses in the form of questionnaires were compared. RESULTS:Multifocal group was better on the uncorrected near vision than monofocal group(PP>0.05. The contrast sensitivity of multifocal group under scotopia at spatial frequency 3c/d was lower than that of monofocal group(PP>0.05. Delensed rate of multifocal group was higher than that of monofocal group(PP>0.05.CONCLUSION:MIOL with phacoemulsification can provide patient good full range vision, especially on good near vision. The patients with MIOL implanted have a higher delensed rate, less postoperative adverse symptoms, quicker recovery and satisfaction.

  5. Tafluprost once daily for treatment of elevated intraocular pressure in patients with open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Liu Y

    2012-12-01

    Full Text Available Yang Liu, Weiming MaoDepartment of Cell Biology and Anatomy, North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TXAbstract: Glaucoma is a leading cause of visual loss worldwide. Current antiglaucoma therapy focuses on lowering intraocular pressure to a safe level. In recent years, prostaglandin analogs have become the first-line agents for treating open angle glaucoma. Tafluprost, which was first reported in 2003, is a novel prostaglandin analog, and has been shown to be a potent ocular hypotensive agent in a number of preclinical and clinical studies. Also, its unique preservative-free formulation helps to decrease preservative-associated ocular disorders and improve patient compliance. In this review, studies from 2003 to 2012 focusing on the structure, metabolism, efficacy, and safety of tafluprost are summarized. These studies suggested that application of tafluprost once daily is a safe and effective treatment for patients with open angle glaucoma.Keywords: tafluprost, prostaglandin analog, glaucoma, intraocular pressure, preservative-free formulation

  6. Clinical observation of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract in the sight restoration project

    Directory of Open Access Journals (Sweden)

    Xiao-Jian Cheng

    2014-04-01

    Full Text Available AIM: To analyze the clinical effects of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract.METHODS:Totally 642 cases 676 eyes of cataract were treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Complication during and after operations and postoperative visual acuity was observed.RESULTS:Visual acuity of 670 eyes was ≥0.05 and off-blindness rate was 99.11%, and there was 627 eyes ≥0.3 and the off-disability rate was 92.75% after 1mo. Rupture of posterior capsule during surgery occurred in 24 eyes. Fifty-four eyes were corneal edema, and anterior chamber exudation were 26 eyes, and 23 eyes were hypertension after operation. CONCLUSION: There are a little complications during and after operation for cataract treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Patients have good recovery after operation. This operation does not need high-standard equipments and is suitable in the sight restoration project.

  7. The case for intraocular delivery of PPAR agonists in the treatment of diabetic retinopathy.

    LENUS (Irish Health Repository)

    Treacy, Maxwell P

    2012-09-01

    Systemic therapeutics targeting the peroxisome proliferator-activated receptors have been found to be beneficial in the treatment of diabetic retinopathy. In this paper, we provide a rationale for the use of these therapeutics as intraocular agents. In addition, we introduce the peroxisome proliferator-activated receptors and describe their functions in response to the drugs.

  8. [Intraocular lens implantation with one loop haptic amputated: a new propose to the subluxation lens surgical treatment].

    Science.gov (United States)

    Ventura, Marcelo; Endriss, Daniela

    2010-01-01

    To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 +/- 5.4 years old, and the mean follow-up period was 21.5 +/- 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL) implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (psubluxation surgical treatment, promoting lens centralization and postoperative visual acuity improvement.

  9. Implantation of a double iris-claw intraocular lens in an aphakic nanophthalmic eye

    Directory of Open Access Journals (Sweden)

    Filiz Avsin Ozdemir Sarioglu

    2017-01-01

    Full Text Available A 55-year-old female with an aphakic nanophthalmic eye underwent a secondary intraocular lens implantation (IOL with double Artisan aphakia iris claw IOLs (ICIOLs and was evaluated in this research. The patient's preoperative best-corrected visual acuity (BCVA of the right eye was 0.4 (0.4 logMAR (with + 21.00 D, postoperative 1st and 3rd month, 1st year, and 3 years BCVAs were 0.4 (0.4 logMAR. The intraocular pressure was 15 mmHg preoperatively, and 14, 12, 12, and 15 mmHg postoperatively at 1st and 3rd month, 1st year, and 3 years, respectively. The preoperative endothelial cell density (ECD was 2372 cells/mm2, and postoperative ECDs were 2352, 2391, 2246, and 2240 cells/mm2 at 1st and 3rd months, at 1st year, and 3 years respectively. In aphakic nanophthalmic eyes with inadequate capsular support, which require high IOL dioptry, the implantation of double ICIOLs (one in front of the iris and the other behind the iris seems to be safe and provides good visual rehabilitation.

  10. Bottom-up fabrication of zwitterionic polymer brushes on intraocular lens for improved biocompatibility

    Directory of Open Access Journals (Sweden)

    Han Y

    2016-12-01

    Full Text Available Yuemei Han,1,* Xu Xu,1,* Junmei Tang,1,* Chenghui Shen,2 Quankui Lin,1,2 Hao Chen1,2 1School of Ophthalmology & Optometry, Eye Hospital, Wenzhou Medical University, 2Wenzhou Institute of Biomaterials and Engineering, Chinese Academy of Sciences, Wenzhou, People’s Republic of China *These authors contributed equally to this work Abstract: Intraocular lens (IOL is an efficient implantable device commonly used for treating cataracts. However, bioadhesion of bacteria or residual lens epithelial cells on the IOL surface after surgery causes postoperative complications, such as endophthalmitis or posterior capsular opacification, and leads to loss of sight again. In the present study, zwitterionic polymer brushes were fabricated on the IOL surface via bottom-up grafting procedure. The attenuated total reflection-Fourier transform infrared and contact angle measurements indicated successful surface modification, as well as excellent hydrophilicity. The coating of hydrophilic zwitterionic polymer effectively decreased the bioadhesion of lens epithelial cells or bacteria. In vivo intraocular implantation results showed good in vivo biocompatibility of zwitterionic IOL and its effectiveness against postoperative complications. Keywords: RAFT, surface modification, endophthalmitis, PCO, in vivo

  11. Analysis of phakic before intraocular lens implantation for fundus examination

    Directory of Open Access Journals (Sweden)

    Juan Chen

    2014-10-01

    Full Text Available AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL. To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examination by three mirror from April 2011 to April 2012 in our hospital. The age, refractive diopter, the findings of Goldmann three mirror examination and the condition of retinal photocoagulation were analysed and concluded.RESULTS: A total of 34 eyes(26.8%out of all 127 eyes(64 caseswere found to have peripheral retinal pathological changes. Eight eyes(6.3%with retinal holes, 15 eyes(11.8%with retinal lattice degeneration, 5 eyes(3.9%with retina cream degeneration, 3 eyes(2.4%with retinal paving stone degeneration,2 eyes with vitreoretinal adhesion and traction,1 eye(0.8%with retinal hemorrhage. Twenty-five cases were given retinal photocoagulation and then received the ICL implantation after 3mo. The follow-up time was 1a. No retinal detachment happened.CONCLUSION:Phakic before intraocular lens implantation for fundus examination by three mirror is contributed to find the peripheral retinal pathological changes and abnormity. And make the appropriate treatment before operation for improving the security of operation, it can also give help to the postoperative follow-up of the fundus of these patients.

  12. Midline sclerotomy approach for intraocular foreign body removal in phakic eyes using endoilluminator: A novel technique

    Science.gov (United States)

    Ravani, Raghav; Chawla, Rohan; Azad, Shorya Vardhan; Gupta, Yogita; Kumar, Vinod; Kumar, Atul

    2018-01-01

    Purpose: The objective of this study is to describe the removal of retained intraocular foreign body (RIOFB) by bimanual pars plana vitrectomy through midline sclerotomy in phakic patients. Technique: Four eyes with RIOFB and clear lens underwent microincision vitrectomy surgery. A chandelier illumination was placed through one of the existing ports. The foreign body (FB) was localized by direct visualization (intravitreal) or indentation (pars plana), stabilized using an intraocular magnet/FB forceps introduced through a midline sclerotomy and freed of vitreous from all sides using a vitrectomy cutter through the other port bimanually, reoriented along their long axis and extracted through the midline sclerotomy. Results: All four FBs were removed successfully without slippage or damage to the clear lens. Conclusion: Chandelier illumination-assisted removal of FB through midline sclerotomy helps in easier localization, stabilization and removal, avoiding lens touch even in anteriorly located FBs such as at pars plana. PMID:29676316

  13. Cauterization technique for suture erosion in transscleralfixation of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Xu-Ting Hu

    2013-12-01

    Full Text Available Transscleral suturing is a commonly applied technique to fix intraocular implants in the sulcus. A major problem after transscleral implantation is suture erosion that normally happens in the late post-surgery period and may result in an increased incidence of endophthalmitis. Here we describe an original cauterization method by using a glass rod to melt the exposed suture end without damaging the suture knot in the sclera to avoid suture exposure in sclera-fixed IOL implantation. This is a simple, quick and effective technique that can be performed without conjunctiva incisions and will help to reduce suture erosion related complications.

  14. Light transmission through intraocular lenses with or without yellow chromophore (blue light filter) and its potential influence on functional vision in everyday environmental conditions.

    Science.gov (United States)

    Owczarek, Grzegorz; Gralewicz, Grzegorz; Skuza, Natalia; Jurowski, Piotr

    2016-01-01

    In this research the factors used to evaluate the light transmission through two types of acrylic hydrophobic intraocular lenses, one that contained yellow chromophore that blocks blue light transmission and the other which did not contain that filter, were defined according to various light condition, e.g., daylight and at night. The potential influence of light transmission trough intraocular lenses with or without yellow chromophore on functional vision in everyday environmental conditions was analysed.

  15. The effect of blue-blocking and neutral intraocular lenses on circadian photoentrainment and sleep one year after cataract surgery

    DEFF Research Database (Denmark)

    Brøndsted, Adam Elias; Haargaard, Birgitte; Sander, Birgit

    2017-01-01

    surgery with implantation of either a neutral or a blue-blocking intraocular lens (IOL). Main outcome was activation of the intrinsically photosensitive retinal ganglion cells (ipRGC) measured by chromatic pupillometry. The circadian rhythm was analysed by 24-hr melatonin profiles and actigraphy......PURPOSE: To compare the long-term effect on circadian photoentrainment and sleep in patients implanted with neutral and blue-blocking intraocular lenses 1 year after cataract surgery. METHODS: Randomized, controlled trial involving 67 patients with age-related cataract. Intervention was cataract...... compared with neutral IOLs. Cataract surgery improved the response of ipRGCs and sleep quality. However, the effect of cataract surgery on sleep quality may be unrelated to circadian photoentrainment....

  16. Comparison of the visual and intraocular optical performance of a refractive multifocal IOL with rotational asymmetry and an apodized diffractive multifocal IOL.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José

    2012-02-01

    To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.

  17. Occult intraocular trauma: evaluation of the eye in an austere environment.

    Science.gov (United States)

    Sweet, Patrick H

    2013-03-01

    Physicians deployed to austere environments often encounter the challenge of needing to make clinical decisions based upon rudimentary history and physical examination. These skills, however, can be difficult for many to rely on, with the many subtleties of examining the eye, when they are normally accustomed to relying on sophisticated modalities to establish diagnosis. This case is a model for evaluating eye trauma in an austere or hostile environment. A 25-year-old male U.S. Marine was fired upon at a Mexican Army checkpoint where he sustained glass shrapnel injuries, the most serious being to his right eye. He was taken from a detention facility to a Mexican hospital, where he was evaluated and given the diagnosis of corneal laceration. Twelve hours later, a U.S. Navy physician arrived to evaluate the patient; he was allowed limited access to the patient. His ophthalmologic examination revealed a closed corneal laceration on the right eye, worse than 20/800 vision, absent red reflex, and obscured funduscopic examination. These findings made it impossible to rule out globe penetration. The patient was released 48 h later to a U.S. Naval Hospital, where intraocular foreign bodies were confirmed by imaging and he was taken to emergency surgery. This case illustrates that even under austere conditions, a focused history and evaluation can reveal the likelihood of occult intraocular foreign body, thereby triaging the patient for emergency surgery. Published by Elsevier Inc.

  18. Use of intraocular lenses in children with traumatic cataract in south India

    OpenAIRE

    Eckstein, M.; Vijayalakshmi, P; Killedar, M.; Gilbert, C.; Foster, A.

    1998-01-01

    AIMS—To assess the long term results of intraocular lens (IOL) implantation for traumatic cataract in young children in a developing country.
METHODS—Prospective hospital based study of 52 children (age 2-10 years) undergoing unilateral cataract extraction and IOL insertion for traumatic cataract performed by a single surgeon in south India. Children were reviewed regularly and followed up initially for 3 years.
RESULTS—There were no serious operative complications. Clinically significant pos...

  19. Bilateral intraocular lens subluxation secondary to haptic angulation.

    Science.gov (United States)

    Moreno-Montañés, Javier; Fernández-Hortelano, Ana; Caire, Josemaría

    2008-04-01

    An 82-year-old man had uneventful phacoemulsification with bilateral implantation of a hydrophilic acrylic, single-piece intraocular lens (IOL) (ACR6D SE, Laboratoires Cornéal). Five years later, simultaneous and bilateral IOL subluxations occurred. In both eyes, the subluxation was situated on the side of one haptic that had moved forward (temporal area in the right eye and superior area in the left eye). In the right eye, the haptic-capsular bag was entrapped by the pupil and produced endothelial damage. A transscleral suture was placed over and under the subluxated haptic through the anterior and posterior capsules to capture the haptic. The haptic was then sutured to the sclera. No postoperative complications developed. We hypothesize that 10-degree angulated and broad haptic junctions can lead to zonular damage and IOL subluxation.

  20. COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT WITH NON-CONTACT TONOMETRY AND APPLANATION TONOMETRY AMONG VARIOUS CENTRAL CORNEAL THICKNESS GROUPS

    Directory of Open Access Journals (Sweden)

    Radhakrishnan B

    2018-02-01

    Full Text Available BACKGROUND Glaucoma is the second leading cause of blindness worldwide. Intraocular Pressure (IOP is the only known modifiable risk factor that has been shown to delay progression in both ocular hypertension and glaucoma patients. Clinical measurement of IOP has undergone several technical advances from the initial digital tension measurements, through indentation tonometry, to applanation tonometry and non-contact tonometry. This study was done to compare the intraocular pressure (IOP measurements with Non Contact Tonometry (NCT and Goldmann Applanation tonometry (GAT and to compare NCT IOP and GAT IOP among various central corneal thickness (CCT groups. MATERIALS AND METHODS IOP measurements were done by NCT and then by GAT followed by CCT. All IOP readings were taken in the sitting position over fifteen minutes. NCT was performed before the GAT to avoid the known mild reduction of IOP by anterior chamber compression with GAT. RESULTS The study included 200 eyes of 100 patients. Mean age of the patients was 58.14 ± 11.7 years (range 35- 81 years. The study population consisted of 58 males and 42 females. The mean ± SD intraocular pressure measurements were 23.39 ± 4.6 mmHg and 22.41 ± 5.9 mmHg for NCT and GAT, respectively. The difference between the NCT and GAT IOP was 0.98 ± 4.7 mm Hg. Mean CCT of the study group was 545.74 ± 38.23 microns. The IOP measured with both GAT and NCT showed no significant change with increasing CCT. The difference between the means increases with increasing CCT upto 600 microns. At lower IOPs ≤ 20 mm Hg, GAT measures are higher than NCT and this relationship is reversed at high IOPs. CONCLUSION Intraocular pressure measurement by NCT was consistently higher than GAT. There was a tendency for NCT to underestimate IOP at lower ranges and overestimates IOP at higher ranges. By applying appropriate correction factor for CCT, Noncontact tonometry could be used as a good screening tool for glaucoma evaluation.

  1. Use of hydroxypropylmethylcellulose 2% for removing adherent silicone oil from silicone intraocular lenses

    OpenAIRE

    Wong , S Chien; Ramkissoon , Yashin D; Lopez , Mauricio; Page , Kristopher; Parkin , Ivan P; Sullivan , Paul M

    2009-01-01

    Abstract Background / aims: To investigate the effect of hydroxypropylmethylcellulose (HPMC) on the physical interaction (contact angle) between silicone oil and a silicone intraocular lens (IOL). Methods: In vitro experiments were performed, to determine the effect of HPMC (0.5%, 1% or 2%), with or without an additional simple mechanical manoeuvre, on the contact angle of silicone oil at the surface of both silicone and acrylic (control) IOLs. A balanced salt solu...

  2. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  3. In-the-bag decentration of a hydrophilic radially asymmetric multifocal intraocular lens secondary to capsule contraction.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2013-01-01

    We report a case of in-the-bag decentration and tilt of a hydrophilic rotationally asymmetric multifocal intraocular lens (IOL) of the M Plus type secondary to capsule contraction. After uneventful surgery and follow-up for 3 months, progressive decentering and tilting of the IOL secondary to

  4. Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia.

    NARCIS (Netherlands)

    Odenthal, M.T.; Eggink, C.A.; Melles, G.R.J.; Pameyer, J.H.; Geerards, A.J.; Beekhuis, W.H.

    2002-01-01

    OBJECTIVES: To describe the refractive results of cataract surgery after photorefractive keratectomy (PRK) for patients with myopia, and to find a more accurate method to predict intraocular lens (IOL) power in these cases. DESIGN: Nonrandomized, retrospective clinical study. PATIENTS AND METHODS:

  5. A noncontact intraocular pressure measurement device using a micro reflected air pressure sensor for the prediagnosis of glaucoma

    International Nuclear Information System (INIS)

    Kim, Kyoung Hwan; Kim, Byeong Hee; Seo, Young Ho

    2012-01-01

    This study investigates a novel, portable tonometer using a micro reflected air pressure sensor for the prediagnosis of glaucoma. Because glaucoma progresses slowly and is not painful, glaucoma patients require a portable prediagnosis system to periodically measure intraocular pressure at home. Conventionally, intraocular pressure is measured by an air-puff tonometer whereby the cornea is deformed by a short pulse of air pressure and the magnitude of the corneal deformation is measured by optic systems such as a combination of laser- and photodiodes. In this study, a micro reflected air pressure sensor was designed, fabricated, and tested in order to measure the magnitude of corneal deformation without optic systems. In an experimental study, artificial eyes with different internal pressures were fabricated and these pressures were measured by the aforementioned system. (paper)

  6. Intraocular pressure and Schirmer tear test values in maned wolf (Chrysocyon brachyurus

    Directory of Open Access Journals (Sweden)

    Cristiane S. Honsho

    Full Text Available Abstract: The purpose of this study was to establish baseline data on lacrimal quantity (STT-1 and intraocular pressure (IOP in captive maned wolves. Ten healthy adult maned wolves were contained with a snare pole and muzzle and kept in decubitus of the left side. STT-1 measurement was performed on the lateral third of the lower conjunctival sac for one minute. The cornea was desensitized and intraocular pressure was measured with an tonopen. Average STT-1 in both eyes was 11±5mm.min-1, with no statistical difference between the left and right eye (p=0.960. Average IOP in both eyes was 20±6mmHg, with no statistical difference between the left and right eye (p=0.836. Average STT-1 was lower than, and IOP was the same as normal levels found in dogs. There was no statistical difference in the age of the animals, and STT-1 and IOP values. In the present paper, average maned wolf STT-1 levels were lower compared with those found in dogs, while the IOP was the same in maned wolves as in dogs. Due to the increased incidence in providing emergency care for maned wolf victims of road kill and fires, determination reference values of ocular parameters may improve the correct diagnosis and treatment of the disease.

  7. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  8. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  9. CORRELATION OF INTRAOCULAR PRESSURE MEASUREMENTS WITH NON CONTACT TONOMETER AND GOLDMANN APPLANATION TONOMETRY

    Directory of Open Access Journals (Sweden)

    Leya Sara George

    2017-07-01

    Full Text Available BACKGROUND A complete ophthalmologic examination includes intraocular pressure (IOP measurement, which is a routine procedure and is important for diagnosis and monitoring of glaucoma. IOP measurement is most commonly done using Goldmann Applanation tonometer and Non-Contact tonometer. MATERIALS AND METHODS In this study IOP measurements of 500 eyes (glaucomatous and non-glaucomatous were performed using GAT and NCT on patients visiting the outpatient clinic of Department of Ophthalmology at Christian Medical College and Hospital, Ludhiana. This was a cross sectional and observational study. Comparison of IOP values was done in different IOP ranges. CCT was measured and analysis of its correlation with GAT and NCT was done. RESULTS Both methods of tonometry correlated significantly in patients with IOP <24 mm Hg. The mean IOP measured by NCT, was 16.06 ± 5.85 mm Hg and the mean IOP measurement by GAT was 16.61 ± 6.94 mm Hg. Intraocular pressure readings with GAT and NCT positively correlated with CCT. CONCLUSION NCT may be useful for screening in clinical settings but borderline high IOP readings should be confirmed with GAT. Our findings, also suggest that CCT is an essential variable to consider in interpreting IOP readings.

  10. A Case of Iris Melanocytoma Demonstrating Diffuse Melanocytic Proliferation with Uncontrolled Intraocular Pressure

    Directory of Open Access Journals (Sweden)

    Mami Kusunose

    2017-03-01

    Full Text Available We report a rare case with histologically proven melanocytoma of the iris that demonstrated diffuse melanocytic proliferation with uncontrolled secondary glaucoma and investigate the etiology of the intraocular pressure elevation. The patient was a 78-year-old man with a history of darkened iris of his left eye. The intraocular pressure was 39 mm Hg. A slit-lamp examination showed a diffuse darkened iris, and a gonioscopic examination revealed open angle with circumferential heavy pigmentation. There was no pigment dispersion of the anterior chamber and no pigment deposition of the cornea. We suspected malignant ring melanoma in the left eye and enucleated it. The globe was examined with light and electron microscopy. Light microscopy revealed the presence of heavily pigmented tumor cells in the iris, ciliary body, trabecular meshwork, and Schlemm’s canal. A bleached preparation showed large tumor cells with central and paracentral nuclei without mitosis. Electron microscopy of the trabecular meshwork revealed melanin-bearing tumor cells invading the intertrabecular spaces, and the melanin granules were not phagocytosed in the trabecular cells. The mechanical obstruction of the aqueous flow by the tumor cells may be a major cause of secondary glaucoma in eyes with iris melanocytoma presenting diffuse proliferation.

  11. Dosimetry and treatment planning of Occu-Prosta 125I seeds for intraocular lesions

    International Nuclear Information System (INIS)

    Chaudhari, Suresh; Deshpande, Sudesh; Anand, Vivek; De, Sandeep; Kannan, V.; Saxena, Sanjay; Dash, A.; Basu, Mahua; Samant, Preetam

    2008-01-01

    Intraocular malignant lesions are frequently encountered in clinical practice. Plaque brachytherapy represents an effective means of treatment for intraocular lesions. Recently Radiopharmaceutical Division, BARC, Mumbai, has indigenously fabricated reasonable-cost 125 I sources. Here we are presenting the preliminary experience of dosimetry of sources, configuration of treatment planning system (TPS) and quality assurance (QA) for eye plaque therapy with Occu-Prosta 125 I seeds, treated in our hospital, for a patient with ocular lesions. 125 I seeds were calibrated using well-type chamber. BrachyVision TPS was configured with Monte Carlo computed radial dose functions and anisotropy functions for 125 I sources. Dose calculated by TPS at different points in central axis and off axis was compared with manually calculated dose. Eye plaque was fabricated of 17 karat pure gold, locally. The seeds were arranged in an outer ring near the edge of the plaque and in concentric rings throughout the plaque. The sources were manually digitized on the TPS, and dose distribution was calculated in three dimensions. Measured activity using cross-calibrated well-type chamber was within ± 10% of the activity specified by the supplier. Difference in TPS-calculated dose and manually calculated dose was within 5%. Treatment time calculated by TPS was in concordance with published data for similar plaque arrangement. (author)

  12. Principales métodos para el cálculo de la lente intraocular después de la cirugía refractiva corneal

    Directory of Open Access Journals (Sweden)

    Taimí Cárdenas Díaz

    Full Text Available Con el surgimiento y el desarrollo de la cirugía refractiva corneal se han podido corregir quirúrgicamente a millones de pacientes con defectos refractivos. Con el cursar de los años comienza a opacarse fisiológicamente el cristalino, y disminuye la agudeza visual en estos pacientes a quienes se les modificó la curvatura corneal. Ante la necesidad de remover el cristalino y de calcular una lente intraocular de potencia adecuada para conseguir la emetropía, surge un nuevo reto a la Oftalmología. El cálculo de la lente intraocular en pacientes con cirugía refractiva corneal es mucho más complejo, pues además de tener longitudes axiales extremas, se añaden factores por la intervención previa que alteran la predictibilidad del resultado visual, con la aplicación de las fórmulas de cálculo de lente intraocular existentes. Se han descrito varios métodos que permiten determinar correctamente la potencia de la lente a implantar, dependiendo de los datos de los que se dispongan; de ahí la motivación para realizar una revisión de diferentes publicaciones con el propósito de describir los principales métodos empleados para realizar el cálculo de la lente intraocular en estos pacientes. Se utilizó la plataforma Infomed, específicamente la Biblioteca Virtual de Salud, con todos sus buscadores.

  13. Intraocular lens dislocation after whole-body vibration.

    Science.gov (United States)

    Vela, José I; Andreu, David; Díaz-Cascajosa, Jesús; Buil, José A

    2010-10-01

    We present 2 cases of intraocular lens (IOL) dislocation that appeared shortly after the patients exercised on a vibration platform. The first patient was a 71-year-old woman who presented with lens subluxation in her right eye and a complete posterior IOL dislocation in her left eye. The second case was a 62-year-old woman who presented with unilateral IOL dislocation within the capsular bag in her right eye. Timing from IOL implantation to dislocation was approximately 6 years and 4 years, respectively. Pars plana vitrectomy with removal of the dislocated IOL was performed in both patients. Whole-body vibration training has become increasingly popular as a form of exercise training. It reportedly may provide benefits in physical function and in some diseases, especially in older people. However, evidence-based protocols ensuring safety and efficacy in this population are lacking. We discuss vibration as a cause of late IOL dislocation. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Comparação da análise da frente de onda e da sensibilidade ao contraste em olhos pseudofácicos com implante de lentes intra-oculares esférica e asférica Wavefront analysis and contrast sensitivity comparison between spheric and aspheric intraocular lenses

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2008-06-01

    Full Text Available OBJETIVO: Comparar a análise da frente de onda e a sensibilidade de contraste pós-operatórias em pacientes submetidos à facoemulsificação com implante de lentes intra-oculares esféricas num olho e asféricas no olho contralateral. MÉTODOS: Este estudo prospectivo comparativo, randomizado, duplo-cego, incluiu 32 olhos de 16 pacientes. Uma avaliação oftalmológica completa foi realizada durante as visitas antes e depois da cirurgia (no primeiro, terceiro, sétimo, e nonagésimo dias pós-cirúrgicos, que incluiu acuidade visual, teste de sensibilidade ao contraste, aberrometria. Todos exames (menos aberrometr=ia foram feitos monocularmente com pupilas não dilatadas. Os pacientes foram submetidos a facectomia ultra-sônica convencional com implante de uma lente asférica SN60WF num olho e esférica SN60ATno outro. RESULTADOS: A acuidade visual média com a melhor correção foi -0,146 LogMAR no grupo da lente intra-ocular esférica, e -0.165 logMAR no grupo da lente intra-ocular asférica sob condições fotópicas, -0,003 LogMAR sob condições mesópicas. A sensibilidade ao contraste foi semelhante em ambos os grupos tanto em condições fotópicas e mesópicas. Em relação às aberrações ópticas ocorreu uma diferença significativa nas aberrações totais (1,09 ± 0,56 no grupo asférico e 1,52 ± 1,19 no grupo esférico e no componente esférico das aberrações de alta ordem(0,422 ± 0,202 no grupo asférico e 0,124 ± 0,087 no grupo esférico. CONCLUSÃO: As duas lentes intra-oculares promoveram uma excelente visão em situações de alto contraste, e os olhos implantados com a lente asférica tiveram menos aberrações totais e esféricas que aqueles implantados com a lente esférica.PURPOSE: Compare the wavefront and contrast sensitivity of bilateral pseudophakic patients with aspheric in one eye and spheric intraocular lenses in the other. METHODS: This prospective, comparative, randomized study, double masked, included 32

  15. Genome-wide analysis of multi-ancestry cohorts identifies new loci influencing intraocular pressure and susceptibility to glaucoma

    NARCIS (Netherlands)

    Hysi, Pirro G.; Cheng, Ching-Yu; Springelkamp, Henriet; Macgregor, Stuart; Bailey, Jessica N. Cooke; Wojciechowski, Robert; Vitart, Veronique; Nag, Abhishek; Hewitt, Alex W.; Hohn, Rene; Venturini, Cristina; Mirshahi, Alireza; Ramdas, Wishal D.; Thorleifsson, Gudmar; Vithana, Eranga; Khor, Chiea-Chuen; Stefansson, Arni B.; Liao, Jiemin; Haines, Jonathan L.; Amin, Najaf; Wang, Ya Xing; Wild, Philipp S.; Ozel, Ayse B.; Li, Jun Z.; Fleck, Brian W.; Zeller, Tanja; Staffieri, Sandra E.; Teo, Yik-Ying; Cuellar-Partida, Gabriel; Luo, Xiaoyan; Allingham, R. Rand; Richards, Julia E.; Senft, Andrea; Karssen, Lennart C.; Zheng, Yingfeng; Bellenguez, Celine; Xu, Liang; Iglesias, Adriana I.; Wilson, James F.; Kang, Jae H.; van Leeuwen, Elisabeth M.; Jonsson, Vesteinn; Thorsteinsdottir, Unnur; Despriet, Dominiek D. G.; Ennis, Sarah; Moroi, Sayoko E.; Martin, Nicholas G.; Jansonius, Nomdo M.; Yazar, Seyhan; Tai, E-Shyong

    2014-01-01

    Elevated intraocular pressure (IOP) is an important risk factor in developing glaucoma, and variability in IOP might herald glaucomatous development or progression. We report the results of a genome-wide association study meta-analysis of 18 population cohorts from the International Glaucoma

  16. Survey of ophthalmic anterior segment findings and intraocular pressure in 95 North American box turtles (Terrapene spp.).

    Science.gov (United States)

    Espinheira Gomes, Filipe; Brandão, João; Sumner, Julia; Kearney, Michael; Freitas, Inês; Johnson, James; Cutler, Daniel; Nevarez, Javier

    2016-03-01

    To describe the ophthalmic biomicroscopy findings and intraocular pressures (IOP) in a captive population of box turtles and to determine whether a relationship exists between body morphometrics or health status and IOP. Hundred and three box turtles (69 Gulf coast, 24 three-toed, one ornate, one eastern, and eight unidentified) were triaged into three different color-coded groups: green (healthy), yellow (abnormal physical examination with no need for immediate care), and red (immediate care required). Both eyes were evaluated by rebound tonometry and slit-lamp biomicroscopy. Body weight and morphometric data were recorded. Intraocular pressures measurements were available for 190 eyes, slit-lamp biomicroscopy was available for 170 eyes, and morphometric data were available for 81 turtles. IOP in Gulf coast turtles (138 eyes) was 6.7 ± 1.4 mmHg OU. IOP in three-toed turtles (48 eyes) was 8.3 ± 1.5 mmHg OU, which was significantly higher than in Gulf coast turtles (P turtles only. There was a mild negative correlation between morphometrics and IOP in Gulf coast and three-toed turtles. Fifteen of 87 turtles had unilateral corneal or lenticular opacities; 3/87 had bilateral corneal or lenticular disease; and 3/87 had adnexal abnormalities. Different subspecies of box turtles have different normal intraocular pressures as measured by rebound tonometry, which was influenced by the animals' health status in one subspecies. Some morphometric parameters were found to be associated with IOP. Box turtles are often affected with ophthalmic abnormalities of unknown clinical significance. © 2015 American College of Veterinary Ophthalmologists.

  17. Short-term intraocular pressure changes after intravitreal injection of bevacizumab in diabetic retinopathy patients

    Directory of Open Access Journals (Sweden)

    Farhood QK

    2014-03-01

    Full Text Available Qasim Kadhim Farhood,1 Sinan Mohammad Twfeeq21College of Medicine, Babylon University, Babylon; 2Al-Jumhori teaching hospital, Mosul, IraqBackground: This study examined the changes in short-term intraocular pressure (IOP in a prospective series of patients undergoing intravitreal bevacizumab injection. The aim was to evaluate the frequency and predictive factors related to intraocular pressure (IOP elevation in patients receiving intravitreal bevacizumab.Patients and methods: This study included 52 patients with diabetic retinopathy between 28 to 75 years of age with a mean age of 51 years; 30 (58% were females, and 22 (42% were males. All patients received bevacizumab (1.25 mg/0.05 mL injected intravitreally in a standard fashion between May 2012 to February 2013 in the AL-Jumhoury teaching hospital. IOP was measured at baseline, 5, 10, and 30 minutes after injection using Goldman applanation tonometry.Statistics: Data were analyzed using the SPSS v.12.0 for windows. Basic, demographic, and clinical data were analyzed using means, proportions, and appropriate 95% confidence intervals (CIs.Results: Most patients (85% were diagnosed with proliferative diabetic retinopathy, while 15% presented with diabetic macular edema. The mean IOP values at baseline, 5, 10, and 30 minutes after injection were 14.0 mmHg (95% CI 13.4–14.7, 36.1 mmHg (95% CI 33.5–38.6, 25.7 mmHg (95% CI 23.8–27.5, and 15.5 mmHg (95% CI 12.4–16.51, respectively. Regression analysis showed a trend toward phakic patients having higher IOP at 30 minutes.Conclusion: Intravitreal injection of bevacizumab is safe with respect to short-term IOP changes, as almost all IOP returned to a safe range (<25 mmHg within 30 minutes. Elevated IOP 30 minutes after injection only occurs rarely, so routine prophylactic use of anti-glaucoma medication is not indicated.Keywords: intravitreal injection, bevacizumab, intraocular pressure, Goldmann applanation tonometry

  18. Role of intraocular Leptospira infections in the pathogenesis of Equine Recurrent Uveitis in the Southern United States

    Science.gov (United States)

    To investigate the role of intraocular leptospiral infections in horses with Equine Recurrent Uveitis (ERU) in the southern United States, blood and ocular fluid samples were collected from horses with a history and ocular findings consistent with ERU. Samples were also obtained from control horses ...

  19. Ultraviolet-B phototoxicity and hypothetical photomelanomagenesis: intraocular and crystalline lens photoprotection.

    Science.gov (United States)

    Mainster, Martin A; Turner, Patricia L

    2010-04-01

    Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Optical radiation measurement, analysis, and perspective. Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Crystalline lens UV-B retinal protection is deficient in children and young adults, increasing their potential susceptibility to acute retinal phototoxicity and hypothetical photomelanomagenesis. UV-B radiation has sufficient energy/photon to induce primary melanomagenic DNA lesions, unlike blue light or UV-A radiation. UV-blocking and blue-blocking IOLs have negligible UV-B transmittance. UV-transmitting IOL transmittance of UV-B radiation is equivalent to that of a 15-year-old crystalline lens. If optical radiation exposure is responsible for welders' increased risk of uveal melanoma, then UV-B radiation is the most probable causative agent and spectacle wear is a potential confounding factor in epidemiologic studies of ocular melanoma. Welders under 30 years of age are at greater risk for welding maculopathy than older welders. Children, adults under 30 years of age, and pseudophakic individuals with UV-transmitting IOLs should wear sunglasses in bright environments because of the UV-B window in their crystalline lenses or IOLs. Copyright 2010 Elsevier Inc. All rights reserved.

  20. Prevalence of corneal astigmatism before cataract surgery in northeast China

    Directory of Open Access Journals (Sweden)

    Zuo-Feng Guo

    2016-05-01

    Full Text Available AIM:To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates of Shenyang in northeast China.METHODS:A retrospective survey was used to study the corneal astigmatism which were measured by intraocular lens(IOLMaster optical biometer before cataract surgery between Jan. 1st, 2014 and Dec. 31st, 2014. Descriptive statistics of corneal astigmatism data were analyzed.RESULTS:The keratometric data from 4 543 eyes from 3 821 patients with a mean age of 66.36±10.38y(SD. In 10.50% of eyes, corneal astigmatism was between 0.5 diopters(Dor less; in 30.05% of eyes, it was 0.5-1.0 D; in 23.60%, it was 1.0-1.5 D; in 13.19%, it was 1.5-2.0 D; in 7.68%, it was 2.0-2.5 D; in 6.41%, it was 2.5-3.0 D; in 8.58%, it was 3.0 D or higher. With-the-rule astigmatism was found in 27.69% of eyes, while against-the-rule was found in 53.84% of eyes.CONCLUSION:About 59.46% of eyes in this study had preoperative corneal astigmatism equal to or above 1.0 D. Findings indicated more surgical techniques or toric intraocular lenses to meet the potential demand of the cataract surgery candidates.

  1. Comparison of glare in YAG-damaged intraocular lenses: injection-molded versus lathe-cut.

    Science.gov (United States)

    Bath, P E; Dang, Y; Martin, W H

    1986-11-01

    A comparative analysis of YAG laser intraocular lens (IOL) damage was undertaken on injection-molded and lathe-cut IOLs. Damage sites were evaluated with polarized light. A consistent positive polarization was observed in the damage sites of lathe-cut IOLs. A consistent negative polarization was observed in the damage sites of injection-molded IOLs. The presence of positive polarization in IOL damage sites may be correlated with increased potential for glare. Results and clinical implications are discussed.

  2. Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model

    OpenAIRE

    Zoulinakis, Georgios; Ferrer-Blasco, Teresa

    2017-01-01

    Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in bot...

  3. A comparison of two different formulations of diclofenac sodium 0.1% in the treatment of inflammation following cataract-intraocular lens surgery.

    Science.gov (United States)

    Mester, Ulrich; Lohmann, Chris; Pleyer, U; Steinkamp, G; Völcker, E; Kruger, H; Raj, Palaniswamy Sunder

    2002-01-01

    To compare the efficacy, tolerability and local tolerance of diclofenac sodium 0.1% containing hydroxypropylgamma cyclodextrin preserved with benzalkonium chloride 0.005% (Voltaren Ophtha CD), with that of diclofenac sodium 0.1% preserved with thiomersal 0.004% (Voltaren Ophtha) in the treatment of inflammation after cataract-intraocular lens surgery. Randomised 2:1, double-masked, parallel-group study in six centres in Germany. 299 patients scheduled to undergo phacoemulsification with posterior chamber intraocular lens implantation. Study medications were instilled four times in the 30 minutes before surgery and four times daily from the first postoperative day. The key efficacy variable was the reduction in anterior chamber flare (photons/millisecond) from day 1 to day 6 to 8. Patients underwent comprehensive ocular examinations, including laser flaremetry (KOWA), preoperatively and postoperatively at days 1, 6 to 8 and 24 to 32. 268 patients (Voltaren Ophtha CD 177, Voltaren Ophtha 91) completed the day 6 to 8 visit without any protocol violations. Reduction in the degree of intraocular inflammation with Voltaren Ophtha CD was equivalent to that achieved with Voltaren Ophtha at the day 6 to 8 [95% confidence interval (CI) -3.07 to +0.54] and day 24 to 32 (95% CI -1.44 to +1.40) visits. Although there was no significant (p = 0.464) difference between the two study groups in patients' global assessment of local tolerance at day 24 to 32, ocular discomfort was significantly (p = 0.023) less with Voltaren Ophtha CD compared with Voltaren Ophtha. Voltaren Ophtha CD was as effective and well tolerated but had less ocular discomfort compared with Voltaren Ophtha in the treatment of ocular inflammation after phacoemulsification with intraocular lens implantation. This new formulation of diclofenac sodium 0.1% may be used as an alternative to the existing formulations of ophthalmic diclofenac sodium 0.1%.

  4. Effect of oral administration of carprofen on intraocular pressure in normal dogs.

    Science.gov (United States)

    Meekins, J M; Overton, T L; Rankin, A J; Roush, J K

    2016-08-01

    The aim of this study was to determine the effect of oral administration of carprofen on intraocular pressure in normal dogs. Twelve young adult beagle dogs were randomly assigned to treatment (n = 6) or control (n = 6) groups. After an 11-day acclimation period, the treatment group received approximately 2.2 mg/kg carprofen per os every 12 h for 7 days, and the control group received a placebo gel capsule containing no drug per os every 12 h for 7 days. Intraocular pressure (IOP) was measured by a rebound tonometer at three time points per day (8 am, 2 pm, and 8 pm) during the acclimation (days 1-11) and treatment (days 12-18) phases and for 48 h (days 19-20) after the completion of treatment. There was no statistically significant change in IOP for either eye in the dogs receiving oral carprofen during the treatment phase (days 12-18). After day 4, no significant daily IOP changes were seen in control group dogs. Carprofen administered orally every 12 h for 7 days had no effect on IOP in normal beagle dogs. An acclimation period to frequent IOP measurements of at least 5 days is necessary to establish baseline IOP values and minimize possible anxiety-related effects on IOP measurements. © 2016 John Wiley & Sons Ltd.

  5. Mesopic visual quality after three kinds of aspheric acrylic monofocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Hai-Lun Ji

    2013-08-01

    Full Text Available AIM:To evaluate best corrected visual acuity(BCVAand contrast sensitivity(CSunder mesopic condition with no glare in patients following implantation of three different kinds of aspheric acrylic monofocal intraocular lens(IOLs.METHODS: Seventy-seven cases(90 eyesof age-related cataract patients were selected, who were undergone phacoemulsification and intraocular lens(IOLimplantation in our hospital during December 2011 to November 2012. Preoperatively, the patients were randomly divided into three groups: 30 eyes(25 caseswere implanted with hydrophobic yellow-tinted acrylic(HOYAIOLs in group 1; 30 eyes(28 caseswith hydrophilic acrylic IOLs(Raynerin group 2; 30 eyes(24 caseswith hydrophilic acrylic surface heparin processing IOLs(XOin group 3. All eyes were evaluated at 1 month and 3 months postoperatively. The BCVA and CS under mesopic condition without glare were measured and underwent statistical analysis.RESULTS: There was neither statistically significant difference in the BCVA(P>0.05, nor statistically significant difference in CS results(after standardization of contrast sensitivity value: lgCS(P>0.05between groups under mesopic condition, but the lgCS of the HOYA group decreased slightly. CONCLUSION: There were not marked differences of BCVA and CS between groups of patients at the follow-up intervals of 1 month and 3 months under mesopic condition. The blue-filter type artificial lens may protect the retina, thus, it is advisable to implant yellow-tinted filter blue artificial lens, especially for patients who are children or young persons.

  6. Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag.

    Science.gov (United States)

    Kohnen, Thomas; Kook, Daniel

    2009-08-01

    We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.

  7. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05). Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division

  8. Eye retraction and rotation during Corvis ST 'air puff' intraocular pressure measurement and its quantitative analysis.

    Science.gov (United States)

    Boszczyk, Agnieszka; Kasprzak, Henryk; Jóźwik, Agnieszka

    2017-05-01

    The aim of this study was to analyse the indentation and deformation of the corneal surface, as well as eye retraction, which occur during air puff intraocular pressure (IOP) measurement. A group of 10 subjects was examined using a non-contact Corvis ST tonometer, which records image sequences of corneas deformed by an air puff. Obtained images were processed numerically in order to extract information about corneal deformation, indentation and eyeball retraction. The time dependency of the apex deformation/eye retraction ratio and the curve of dependency between apex indentation and eye retraction take characteristic shapes for individual subjects. It was noticed that the eye globes tend to rotate towards the nose in response to the air blast during measurement. This means that the eye globe not only displaces but also rotates during retraction. Some new parameters describing the shape of this curve are introduced. Our data show that intraocular pressure and amplitude of corneal indentation are inversely related (r 8  = -0.83, P = 0.0029), but the correlation between intraocular pressure and amplitude of eye retraction is low and not significant (r 8  = -0.24, P = 0.51). The curves describing corneal behaviour during air puff tonometry were determined and show that the eye globe rotates towards the nose during measurement. In addition, eye retraction amplitudes may be related to elastic or viscoelastic properties of deeper structures in the eye or behind the eye and this should be further investigated. Many of the proposed new parameters present comparable or even higher repeatability than the standard parameters provided by the Corvis ST. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  9. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  10. [Laser magnetotherapy after cataract extraction with implantation of intraocular lens].

    Science.gov (United States)

    Maksimov, V Iu; Zakharova, N V; Maksimova, I S; Golushkov, G A; Evseev, S Iu

    2002-01-01

    Effects of low-intensive laser and alternating magnetic field on the course of the postoperative period were studied in patients with exudative reaction after extracapsular cataract extraction with implantation of intraocular lens (IOL). The results are analyzed for 148 eyes with early exudative reaction after IOL implantation (136 patients aged 42-75 years). The patients were observed for up to 6 months. The treatment efficiency was evaluated by the clinical picture of inflammatory reaction, visual acuity, and results of biochemical analysis of the lacrimal fluid (the ratio of lipid peroxidation products to antioxidants in cell membrane). The course of the postoperative period was more benign and recovery sooner in patients of the main group in comparison with the control.

  11. Intraocular levels of methotrexate after oral low-dose treatment in chronic uveitis.

    Science.gov (United States)

    Puchta, Joachim; Hattenbach, Lars-Olof; Baatz, Holger

    2005-01-01

    To determine the intraocular levels of methotrexate in low-dose treatment of noninfectious uveitis. One day after oral administration, the methotrexate level was measured in the aqueous humor and serum of a patient with noninfectious uveitis, who underwent cataract surgery. A fluorescence polarization immunoassay was used for determination. After oral administration, methotrexate was only measurable in aqueous humor but not in serum. In uveitis, orally administered low-dose methotrexate reaches detectable levels in aqueous humor, even in the absence of detectable levels in serum. Copyright (c) 2005 S. Karger AG, Basel.

  12. Pesquisa de anticorpos anti Toxoplasma gondii em fluidos intra-oculares (humor vítreo e humor aquoso) de pacientes com toxoplasmose ocular, na cidade de Belém, PA

    OpenAIRE

    Carmo,Ediclei Lima do; Almeida,Edmundo Frota; Bichara,Cléa Nazaré; Póvoa,Marinete Marins

    2005-01-01

    Foi realizada pesquisa de anticorpos IgG, IgM e IgA anti-Toxoplasma gondii no soro e fluidos intra-oculares (humor aquoso e vítreo) de pacientes com toxoplasmose ocular. A partir dos resultados obtidos verificou-se que anticorpos IgG e IgA intraocular anti-Toxoplasma gondii podem vir a ser importantes marcadores no diagnóstico de toxoplasmose ocular.

  13. The diagnostic value of intraocular fluid analysis by polymerase chain reaction in Thai patients with uveitis.

    Science.gov (United States)

    Pathanapitoon, Kessara; Kongyai, Natedao; Sirirungsi, Wasna; de Groot-Mijnes, Jolanda D F; Leechanachai, Pranee; Choovuthayakorn, Janejit; Kunavisarut, Paradee; Rothova, Aniki

    2011-11-01

    Uveitis is a major cause of severe visual impairment throughout the world and can be initiated by various infectious and non-infectious causes. Early recognition of specific infections is important as the treatment with antimicrobial agents might stop the progression or even cure the eye disease. To determine the infectious causes of uveitis in Thailand, intraocular fluid samples of 100 HIV-negative patients and 47 HIV-positive patients with uveitis were examined using real-time PCR analysis for herpes simplex virus, varicella zoster virus, cytomegalovirus and Toxoplasma gondii. Positive PCR results were found in 33/100 (33%) HIV-negative patients and in 33/47 (70%) HIV-positive patients with uveitis. In Thailand, cytomegalovirus was identified as the most frequent cause of infectious uveitis in both HIV-negative and HIV-positive patients (49 and 91%, respectively). PCR analysis of intraocular samples in uveitis was a valuable diagnostic assay. The pattern of uveitis observed in the Far East differs from that found in the West. Copyright © 2011 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

  14. Effect on Intraocular Pressure of Switching from Latanoprost and Travoprost Monotherapy to Timolol Fixed Combinations in Patients with Normal-Tension Glaucoma

    Directory of Open Access Journals (Sweden)

    Ryoko Igarashi

    2014-01-01

    Full Text Available Purpose. To evaluate the effect on intraocular pressure (IOP of switching from latanoprost and travoprost monotherapy to timolol fixed combinations in Japanese patients with normal-tension glaucoma (NTG. Methods. 27 NTG patients (54 eyes were compared IOP, superficial punctuate keratitis (SPK scores, and conjunctival injection scores in eyes treated with prostaglandin (PG or PG analog/beta-blocker (PG/b fixed-combination 6 months after the change in therapy. Results. The mean baseline intraocular pressure was 17.4±1.59 mmHg in eyes receiving PG therapy only and 17.4±1.69 mmHg in eyes switched to PG/b. Switching to fixed combination therapy from PG monotherapy, the mean IOP was 13.1±1.79 mmHg (P<0.001  (-24.71% reduction from baseline at 6 months. The mean conjunctival injection score was 0.69 for eyes on PG monotherapy and 0.56 for eyes on fixed combination therapy (P=0.028. The mean SPK scores were 0.46 and 0.53. This difference was not statistically significant (P=0.463. Conclusions. Switching from PG monotherapy to PG/b fixed combination therapy for NTG resulted in a greater intraocular pressure reduction than PG alone without increasing the number of instillations.

  15. Incidência de opacificação de cápsula posterior em pacientes submetidos à facoemulsificação e implante de lentes intra-oculares acrílicas hidrofílicas expansíveis Incidence of posterior capsule opacification in patients submitted to phacoemulsification and expandable acrylic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Hilton Arcoverde Gonçalves de Medeiros

    2006-06-01

    Full Text Available OBJETIVO: Avaliar prospectivamente os resultados das lentes intra-oculares de polímeros expansíveis implantadas em pacientes submetidos à facoemulsificação, quanto à incidência de opacificação de cápsula posterior, levando em consideração a biocompatibilidade das lentes expansíveis. MÉTODOS: O grupo de estudo foi composto por 830 pacientes, 1.200 olhos, que foram submetidos a facoemulsificação, utilizando a mesma técnica, variando-se apenas o diâmetro da capsulorrexe, pelo mesmo cirurgião, no período de 1998 a 2002, com implante de lente intra-ocular hidrofílica expansível. O acompanhamento médio foi de 2,4 anos, variando de seis meses a quatro anos. RESULTADOS: O número total de opacificação de cápsula posterior foi de 54 casos. CONCLUSÃO: A incidência de opacificação de cápsula posterior encontrada no grupo foi de 4,6%.PURPOSE: To evaluate prospectively the results of expandable acrylic intraocular lenses in patients submitted to phacoemulsification as regard posterior capsule opacification. METHODS: The study group consisted of 830 patients, 1,200 eyes that underwent phacoemulsification from 1998 to 2002, by the same surgeon, using the same technique but with different diameters of capsulorrhexis, with expandable hydrophilic acrylic intraocular lens implantation. The mean follow-up was 2.4 years, ranging from 6 months to 4 years. RESULTS: The total number of posterior capsule opacification was 54 cases. CONCLUSIONS: The incidence of posterior capsule opacification was 4.6% in these patients.

  16. A study of brachytherapy for intraocular tumor

    International Nuclear Information System (INIS)

    Ji, Yung Hoon; Lee, Dong Han; Ko, Kyung Hwan; Lee, Tae Won; Lee, Sung Koo; Choi, Moon Sik

    1994-12-01

    Our purpose of this study is to perform brachytherapy for intraocular tumor. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere. Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm. Maximum error is -11.3% and 0.8 mm, respectively. 7 figs, 2 tabs, 28 refs. (Author)

  17. Motorized injector-assisted intrascleral intraocular lens fixation.

    Science.gov (United States)

    Hung, Jia-Horung; Wang, Shih-Hao; Teng, Yu-Ti; Hsu, Sheng-Min

    2017-03-01

    For eyes with deficient capsular support, intraocular lens (IOL) implantation has long been a technical challenge. Recently, intrascleral fixation of the haptics of a three-piece posterior chamber IOL has become a popular option. In this procedure, externalization of the leading haptic during IOL injection is a stressful step. We present a modified technique to improve the ease and safety of this step. Our modified technique involves IOL injection with a motorized injector with several important modifications described here. With these modifications, a surgeon can easily maintain the correct orientation of the IOL in a well-controlled manner during IOL injection. The records of 13 patients who underwent this technique were retrospectively evaluated. Corrected-distance visual acuity improved significantly after surgery (pIOL decentration, or vitreous hemorrhage was noted during the follow-up period. In conclusion, the motorized injector-assisted intrascleral IOL fixation technique is a safe and effective alternative to the conventional procedure. This technique makes the process of leading haptic externalization easier and more controllable. Copyright © 2017. Published by Elsevier Taiwan.

  18. Motorized injector-assisted intrascleral intraocular lens fixation

    Directory of Open Access Journals (Sweden)

    Jia-Horung Hung

    2017-03-01

    Full Text Available For eyes with deficient capsular support, intraocular lens (IOL implantation has long been a technical challenge. Recently, intrascleral fixation of the haptics of a three-piece posterior chamber IOL has become a popular option. In this procedure, externalization of the leading haptic during IOL injection is a stressful step. We present a modified technique to improve the ease and safety of this step. Our modified technique involves IOL injection with a motorized injector with several important modifications described here. With these modifications, a surgeon can easily maintain the correct orientation of the IOL in a well-controlled manner during IOL injection. The records of 13 patients who underwent this technique were retrospectively evaluated. Corrected-distance visual acuity improved significantly after surgery (p<0.05. No postoperative retinal detachment, endophthalmitis, IOL decentration, or vitreous hemorrhage was noted during the follow-up period. In conclusion, the motorized injector-assisted intrascleral IOL fixation technique is a safe and effective alternative to the conventional procedure. This technique makes the process of leading haptic externalization easier and more controllable.

  19. Preliminary study of a new intraocular method in the diagnosis and treatment of Propionibacterium acnes endophthalmitis following cataract extraction.

    Science.gov (United States)

    Owens, S L; Lam, S; Tessler, H H; Deutsch, T A

    1993-04-01

    Late endophthalmitis, due to Propionibacterium acnes, developed in three patients following uncomplicated extracapsular cataract extraction and posterior chamber intraocular lens (PC-IOL) insertion. Cultures from the capsular bag yielded P. acnes in all three. With topical anesthesia and through an anterior chamber paracentesis, culture specimens were taken from and clindamycin irrigated into the capsular bag. Filtered 100% oxygen was introduced into the anterior chamber in two; the third also received an injection of gentamicin and dexamethasone into the capsular bag. After treatment, two patients received oral antibiotics; one received hyperbaric oxygen therapy. Visual acuity was improved and inflammation reduced in all three. However, after treatment, ocular toxic effects due to clindamycin were suspected in one. This approach offers several clear advantages, including topical anesthesia, outpatient management, elimination of the need for vitrectomy, and retention of the intraocular lens (IOL).

  20. Effect of pegaptanib sodium 0.3 mg intravitreal injections (Macugen) in intraocular pressure: posthoc analysis from VISION study

    NARCIS (Netherlands)

    Boyer, David S.; Goldbaum, Mauro; Leys, Anita M.; Starita, Carla; Blumenkranz, M.; Buyse, M.; Goldberg, M.; Gragoudas, E. S.; Miller, J.; Schwartz, S. D.; Singerman, L.; Yannuzzi, L.; Adamis, A. P.; Guyer, D. R.; O'Shaughnessy, D.; de Gronckel, S.; Fesneau, G.; Quinaux, E.; Tremolet, D.; Wang, K.; Brailey, A.; Finman, J.; Ting, N.; Bressler, N. M.; Bressler, S. B.; Denblow, R.; Schein, O. D.; Seabrook, S.; Solomon, S.; Schachat, A. P.; Philips, D.; Altaweel, M.; Davis, M. D.; Blodi, Ba; Danis, R. P.; Ip, M. S.; Hiner, C.; Elledge, J.; Webster, M.; Hannan, C.; Ficken, J.; Alexander, S.; Neider, M.; Wabers, H.; Vargo, P.; Lambert, E.; Kastorff, L.; Carr, A.; Shkiele, A.; Schlingemann, R. O.

    2014-01-01

    Objective To assess the rate of pegaptanib-associated sustained intraocular pressure (IOP) elevation. Methods A posthoc analysis was conducted on all IOP measurements, except the immediate 30-min postinjection, from all subjects randomised to pegaptanib 0.3 mg or sham injections continuously in the

  1. Systems genetics identifies a role for Cacna2d1 regulation in elevated intraocular pressure and glaucoma susceptibility

    NARCIS (Netherlands)

    Chintalapudi, S.R. (Sumana R.); Maria, D. (Doaa); Di Wang, X. (Xiang); Bailey, J.N.C. (Jessica N. Cooke); Allingham, R. (Rand); M.H. Brilliant (Murray H.); D.L. Budenz (Donald L.); J. Fingert (John); D. Gaasterland (Douglas); T. Gaasterland (Terry); J.L. Haines (Jonathan); Hark, L. (Lisa); M.A. Hauser (Michael); R.P. Igo Jr. (Robert); Hee Kang, J. (Jae); P. Kraft (Peter); R.K. Lee (Richard K.); P.A. Lichter (Paul A.); Liu, Y. (Yutao); Moroi, S. (Syoko); L.R. Pasquale (Louis); M.A. Pericak-Vance (Margaret); A. Realini (Anthony); Rhee, D. (Doug); Richards, J.R. (Julia R.); Ritch, R. (Robert); J.S. Schuman (Joel S.); W.K. Scott (William); K. Singh (Kuldev); A.J. Sit (Arthur J.); D. Vollrath (Douglas); G. Wollstein (Gadi); D.J. Zack (Donald); T. Aung (Tin); Bonnemaijer, P. (Peter); Cheng, C.-Y. (Cheng-Yu); J.E. Craig (Jamie); C.M. van Duijn (Cornelia); P. Gharahkhani (Puya); Iglesias Gonzalez, A. (Adriana); Hammond, C.J. (Christopher J.); Hewitt, A. (Alex); Hoehn, R. (Rene); Jonansson, F. (Fridbert); A.P. Khawaja (Anthony); Chuen Khor, C. (Chiea); C.C.W. Klaver (Caroline); A.J. Lotery (Andrew); D.A. Mackey (David); MacGregor, S. (Stuart); Pang, C. (Calvin); F. Pasutto (Francesca); J-A. Zwart (John-Anker); G. Thorleifsson (Gudmar); Thorsteinsdottir, U. (Unnar); V. Vitart (Veronique); E.N. Vithana (Eranga); T.L. Young (Terri L.); T. Zeller (Tanja); P.G. Hysi (Pirro); J.L. Wiggs (Janey L.); R.W. Williams (Robert W.); Jablonski, M.M. (Monica M.)

    2017-01-01

    textabstractGlaucoma is a multi-factorial blinding disease in which genetic factors play an important role. Elevated intraocular pressure is a highly heritable risk factor for primary open angle glaucoma and currently the only target for glaucoma therapy. Our study helps to better understand

  2. Influence on Visual Quality of Intraoperative Orientation of Asymmetric Intraocular Lenses.

    Science.gov (United States)

    Bonaque-González, Sergio; Ríos, Susana; Amigó, Alfredo; López-Gil, Norberto

    2015-10-01

    To evaluate visual quality when changing the intraocular orientation of the Lentis Mplus LS-312MF nonrotational symmetric +3.00 diopters aspheric multifocal intraocular lens ([IOL] Oculentis GmbH, Berlin, Germany) in normal eyes. An artificial eye was used to measure the in vitro wavefront of the IOL. The corneal topography of 20 healthy patients was obtained. For each eye, a computational analysis simulated the implantation of the IOL. The modulation transfer function (MTF) and an image quality parameter (visually modulated transfer function [VSMTF] metric) were calculated for a 5.0-mm pupil and for three conditions: distance, intermediate, and near vision. The procedure was repeated for each eye after a rotation of the IOL with respect to the cornea from 0° to 360° in 1° steps. Statistical analysis showed significant differences in mean VSMTF values between orientations for distance vision. Optimal orientation of the IOL (different for each eye) showed a mean improvement of 58% ± 19% (range: 20% to 121%) in VSMTF values with respect to the worst possible orientation. For these orientations, intermediate and near vision quality were statistically indistinguishable. The MTFs were different between orientations, showing a mean difference of approximately 5 cycles per degree in the maximum spatial frequencies that can be transferred between the best and the worst orientations for distance vision. The results suggest that implantation of this nonrotational symmetric IOL should improve visual outcomes if it is oriented to coincide with a customized meridian. A simple, practical method is proposed to find an approximation to the angle that an Mplus IOL should be inserted. Copyright 2015, SLACK Incorporated.

  3. Features of YAG-laser treatment of posterior capsule opacification in eyes with intraocular comorbidities ext

    Directory of Open Access Journals (Sweden)

    O. I. Borzunov

    2015-01-01

    Full Text Available Purpose: is to evaluate the effectiveness of YAG laser posterior lens capsule dissection in patients with secondary cataract with concurrent intraocular pathology. Patients and methods: retro- and prospective analysis of the results of the YAG — laser treatment of secondary cataract in the 196 eyes, including the intraocular concomitant pathology (myopia, glaucoma, age-related macular degeneration, diabetic retinopathy, retinitis pigmentosa operated retinal detachment, chronic uveitis in remission, peripheral chorioretinal degeneration. Effectiveness of treatment was evaluated by checking visual acuity and dynamics of complaints as aberration, glare, distortion in the central field of view without proper disease of the macula. Complex preoperative studies included: refractometry, visometry with correction, perimetry, tonometry, biomicroscopy, ophthalmoscopy, ultrasound examination of the eyeball (if necessary. The examination results should demonstrate convincing evidence that posterior capsular opacification is the main reason for the decrease of visual acuity. Results:, Visual acuity, at average increased from 0.4‑0.6 to 0.8‑1.0 in 50 cases after dissection, Visual acuity improved to 2‑3 lines in 66‑4–5, 24‑6‑7 lines in 74 cases. Visual acuity remains the same, but contrast sensitivity was increased in 6 cases. The IOL location after disruption was evaluated by β-scanning and biomicroscopy. In case of the initial correct IOL position in all 195 (100 % cases, there were no dislocation in the postoperative period. Complications that can be identified were single microcraters on the IOL surface in cases of its full contact with the posterior capsule. These injuries did not affect the visual functions.Conclusion: YAG -Laser dissection of secondary cataract is effective, less traumatic, and the optimal treatment of secondary cataract, including patients with concomitant intraocular pathology, and helps to avoid over

  4. Resultados preliminares do implante de lente intra-ocular fácica artisan para correção de miopia Preliminary results of artisan phakic intraocular lens implantation to correct myopia

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2007-06-01

    Full Text Available OBJETIVOS: Avaliar os resultados preliminares quanto à eficácia, estabilidade e segurança da lente intra-ocular de câmara anterior Artisan em olhos fácicos para correção de miopia. MÉTODOS: Foi analisado retrospectivamente o resultado de 34 olhos fácicos que receberam o implante de lente intra-ocular Artisan para correção de miopia. Os parâmetros avaliados foram: contagem endotelial pré e pós-operatória, acuidade visual sem correção pré e pós-operatória, melhor acuidade visual com correção pré e pós-operatória, equivalente esférico pré e pós-operatório, ganho e perda de linhas de visão e complicações. RESULTADOS: Dezoito pacientes (34 olhos foram incluídos neste estudo. Quatorze eram do sexo feminino (77,8% e 4 do sexo masculino. A idade média dos pacientes era de 30 anos (DP ± 7,3, variando de 21 a 46 anos. O período médio de seguimento foi de 8,5 meses (DP ± 3,6. A média de perda endotelial foi de 4,75% em 6 meses. A acuidade visual sem correção pré-operatória era de 0,02 (20/800 variando de 0,01 a 0,13. O equivalente esférico médio pré-operatório na refração dinâmica era de -13,25 D, variando de -5,75 D a -19,75 D. No último seguimento a acuidade visual sem correção era de 0,64 (20/32 variando de 0,33 a 1,00. O equivalente esférico médio na refração dinâmica era de -1,18 D (DP ± 0,92 variando de + 0,25 a -3,0. Entre as complicações observadas em nosso estudo 1 (3,4% paciente apresentou deslocamento da lente por trauma necessitando de uma segunda intervenção para reposicionamento. CONCLUSÃO: O uso de lente fácica de câmara anterior Artisan para correção de miopia no presente estudo se mostrou seguro, eficaz e com boa previsibilidade. No entanto, estudo prospectivo com maior número de casos e maior seguimento é necessário para determinar a segurança do procedimento a longo prazo.PURPOSE: To observe the preliminary results based on the efficacy, stability and safety of

  5. DNA extraction methods for panbacterial and panfungal PCR detection in intraocular fluids.

    Science.gov (United States)

    Mazoteras, Paloma; Bispo, Paulo José Martins; Höfling-Lima, Ana Luisa; Casaroli-Marano, Ricardo P

    2015-07-01

    Three different methods of DNA extraction from intraocular fluids were compared with subsequent detection for bacterial and fungal DNA by universal PCR amplification. Three DNA extraction methods, from aqueous and vitreous humors, were evaluated to compare their relative efficiency. Bacterial (Gram positive and negative) and fungal strains were used in this study: Escherichia coli, Staphylococcus epidermidis and Candida albicans. The quality, quantification, and detection limit for DNA extraction and PCR amplification were analyzed. Validation procedures for 13 aqueous humor and 14 vitreous samples, from 20 patients with clinically suspected endophthalmitis were carried out. The column-based extraction method was the most time-effective, achieving DNA detection limits ≥10(2) and 10(3 )CFU/100 µL for bacteria and fungi, respectively. PCR amplification detected 100 fg, 1 pg and 10 pg of genomic DNA of E. coli, S. epidermidis and C. albicans respectively. PCR detected 90.0% of the causative agents from 27 intraocular samples collected from 20 patients with clinically suspected endophthalmitis, while standard microbiological techniques could detect only 60.0%. The most frequently found organisms were Streptococcus spp. in 38.9% (n = 7) of patients and Staphylococcus spp. found in 22.2% (n = 4). The column-based extraction method for very small inocula in small volume samples (50-100 µL) of aqueous and/or vitreous humors allowed PCR amplification in all samples with sufficient quality for subsequent sequencing and identification of the microorganism in the majority of them.

  6. Heavy Silicone Oil and Intraocular Inflammation

    Directory of Open Access Journals (Sweden)

    Francesco Morescalchi

    2014-01-01

    Full Text Available In the past two decades, many advances have been made in vitrectomy instrumentation, surgical techniques, and the use of different tamponade agents. These agents serve close retinal breaks, confine eventual retinal redetachment, and prevent proliferative vitreoretinopathy (PVR. Long-acting gases and silicone oil are effective internal tamponade agents; however, because their specific gravity is lower than that of the vitreous fluid, they may provide adequate support for the superior retina but lack efficacy for the inferior retina, especially when the fill is subtotal. Thus, a specific role may exist for an internal tamponade agent with a higher specific gravity, such as heavy silicone oils (HSOs, Densiron 68, Oxane HD, HWS 45-300, HWS 46-3000, and HeavySil. Some clinical evidence seems to presume that heavy tamponades are more prone to intraocular inflammation than standard silicone if they remain in the eye for several months. In this review, we discuss the fundamental clinical and biochemical/molecular mechanisms involved in the inflammatory response after the use of heavy tamponade: toxicity due to impurities or instability of the agent, direct toxicity and immunogenicity, oil emulsification, and mechanical injury due to gravity. The physical and chemical properties of various HSOs and their efficacy and safety profiles are also described.

  7. Intraocular lens calculations in atypical eyes

    Directory of Open Access Journals (Sweden)

    Aazim A Siddiqui

    2017-01-01

    Full Text Available Cataract surgery is the most performed surgical procedure in the field of ophthalmology. The process of intraocular lens (IOL calculations is a critical step to achieving successful outcomes. Many IOL formulae exist to guide surgeons through the difficult process of picking the most appropriate lens to achieve a certain target refraction. However, these formulae reach within 0.50 diopters of the target refraction only 75% of the time, leaving 25% of the eyes with a significant refractive surprise. A literature review was performed to investigate all the relevant published material on the history, progress, and recent advancements of IOL calculations. Based on this review, the appropriate history, evolution, progress, limitations, and recent advancements are analyzed and explained. Although the modern IOL formulae and biometric devices perform well for average eyes, they are suboptimal for eyes with atypical biometric parameters and also those that are postrefractive and keratoconic. There has not been a single, perfect formula that can resolve the complexities of this process. Various methods of formula optimization and newer generation of IOL formulae and devices may hold the key to improving outcomes in both typical and atypical eyes. These solutions minimize refractive error by introducing new input parameters and complex mathematical techniques to better estimate postoperative lens position.

  8. Scleral fixation of a single-piece multifocal intraocular lens.

    Science.gov (United States)

    Can, Ertugrul; Basaran, M Resat; Gül, Adem

    2013-01-01

    We describe an ab interno technique for injector implantation of a one-piece multifocal intraocular lens (IOL). Transscleral fixation of multifocal posterior chamber IOL implantation using an injector with ab interno technique was performed in an eye of a 9-year-old girl who had undergone pars plana lensectomy 2 years before for bilateral lens subluxation with unknown etiology. No major complications were encountered during a 3-month follow-up of the patient and excellent centration was observed during the follow-up period. Her preoperative best spectacle-corrected distance visual acuity of 20/32 improved to uncorrected distance visual acuity of 20/25. Closed-loop design of IOL served the function of eyelets and position of the IOL was provided using only a 2-point fixation. Intraoperative position adjustment of the IOL provided an excellent centralization of multifocal IOL.

  9. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models

    OpenAIRE

    Song, Hui; Yuan, Xiaoyong; Tang, Xin

    2016-01-01

    Background In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. Methods A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3?mm of pupil diameter and...

  10. Appraisal of Bleb Using Trio of Intraocular Pressure, Morphology on Slit Lamp, and Gonioscopy

    OpenAIRE

    Thatte, Shreya; Rana, Rimpi; Gaur, Neeraj

    2016-01-01

    Purpose The aim of this study was to assess bleb function using Wuerzburg bleb classification score (WBCS) for bleb morphology on slit lamp, intraocular pressure (IOP), and gonioscopy. Methods A total of randomly selected 30 eyes posttrabeculectomy were assessed for bleb function with the trio of bleb morphology, IOP, and gonioscopy. Bleb was assessed using the WBCS of 0–12 on slit lamp, IOP was assessed using applanation tonometry, and visualization of inner ostium and iridectomy were assess...

  11. Comparison of levobunolol and brimonidine in prophylaxis of intraocular pressure (iop|) rise following nd: yag laser capsulotomy

    International Nuclear Information System (INIS)

    Habib, M.; Akram, A

    2015-01-01

    To compare the efficacy of topical 0.5% Levobunolol and 0.2% Brimonidine in preventing intraocular pressure rise after Nd: YAG laser posterior capsulotomy. Study Design: Randomized controlled trial (RCT). Setting and Duration of Study: Ophthalmology Department Combined Military Hospital Multan, from September 2010 to March 2011. Patients and Methods: A total of 82 patients fulfilling the inclusion criteria were selected from out-patient department and randomly divided into two equal groups. Topical 0.5% levobunolol was instilled in group A while 0.2% brimonidine was instilled in group B one hour before and immediately after doing Nd:YAG laser capsulotomy. The intraocular pressure (IOP) was measured using Goldmann applanation tonometer 1, 3 and 24 hours later. Data was analyzed using SPSS version 15.0. Results: There was no statistically significant difference in mean IOP between 0.5% Levobunolol group (Group A) and 0.2% Brimonidine group (Group B) at 1 hour, 3 hours and 24 hours after Nd:YAG laser capsulotomy. The mean intraocular pressure (IOP) one hour after Nd:YAG laser and topical treatment in group A was 16.10 ± 1.60 mmHg while in group B was 15.65 ± 3.01 mmHg (P=0.401). Mean IOP after three hours in group A was 15.80 ± 1.35 mm Hg and in group B was 15.05 ± 2.15 mmHg (p=0.062). Mean IOP after 24 hours in group A was 15.13 ± 2.05 mmHg while in group B was 14.32 ± 1.62 mmHg (p=0.058). Conclusion: Both 0.5% Levobunolol and 0.2% Brimonidine are equally effective in controlling the IOP spike after Nd: YAG laser capsulotomy. Either of these medicines can be used as a prophylaxis to prevent rise in IOP after Nd:YAG laser capsulotomy. (author)

  12. Diagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients.

    Science.gov (United States)

    Li, Yifan; Carpenter, Christopher R; Nicholson, Kathryn; Milne, William Ken

    2015-12-01

    Vision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate the diagnostic accuracy of the iCare rebound tonometer against the gold standard Perkins applanation tonometer (PAT) in measuring IOP. Patients from two rural communities in Ontario, Canada visiting their optometrists for routine appointments had their IOP measured by a non-contact tonometer (NCT), an iCare rebound tonometer, and a Perkins applanation tonometer (PAT). Values of sensitivity, specificity, and likelihood ratios for a positive and negative result were calculated for the iCare and the NCT. Complete data was collected from 209 patients. Overall, the iCare tonometer had high levels of validity, as compared to the gold standard PAT. The iCare tonometer displayed excellent sensitivity of 98.3% (90-99%, 95% CI) and excellent negative likelihood ratio of 0.024 (0.0088-0.066, 95% CI) which is useful for ruling out intraocular hypertension. The iCare tonometer is a reasonably valid tool for detecting elevated IOP. Its ease of use, simplicity, and accessibility makes it a good screening tool to improve eye health in rural areas.

  13. Preoperative corneal astigmatism among adult patients with cataract in Northern Nigeria

    Directory of Open Access Journals (Sweden)

    Mohammed Isyaku

    2014-01-01

    Full Text Available The prevalence and nature of corneal astigmatism among patients with cataract has not been well-documented in the resident African population. This retrospective study was undertaken to investigate preexisting corneal astigmatism in adult patients with cataract. We analyzed keratometric readings acquired by manual Javal-Schiotz keratometry before surgery between January 1, 2011 and December 31, 2011. There were 3,169 patients (3286 eyes aged between 16 and 110 years involved with a Male to female ratio of 1.4:1. Mean keratometry in diopters was K1 = 43.99 and K2 = 43.80. Mean corneal astigmatism was 1.16 diopter and a majority (45.92% of eyes had astigmatism between 1.00 and 1.99 diopters. Two-thirds of the eyes (66.9% in this study had preoperative corneal astigmatism equal to or above 1.00 diopter. Findings will help local cataract surgeons to estimate the potential demand for toric intraocular lenses.

  14. Resident and young physician experience with complex cataract surgery and new cataract and refractive technology: Results of the ASCRS 2016 Young Eye Surgeons survey.

    Science.gov (United States)

    Schallhorn, Julie M; Ciralsky, Jessica B; Yeu, Elizabeth

    2017-05-01

    A survey was offered to attendees of the 2016 annual meeting of the American Society of Cataract and Refractive Surgery (ASCRS) as well as online to ASCRS members. Of the 429 self-identified surgeons in training or those with fewer than 5 years in practice, 83% had performed complex cataract surgery using iris expansion devices or capsular tension rings (63%) and 70% had implanted a toric intraocular lens (IOL). A minority of respondents had performed laser-assisted cataract surgery (27%) or implanted presbyopia-correcting IOLs (39%), and only half (50%) had performed laser vision correction (LVC). Comfort with complex cataract and IOL procedures improved with increasing number of cases performed until greater than 10 cases. From this we can conclude that young surgeons have adequate exposure to complex cataracts but lack experience in refractive surgery and new IOL technology. Reported surgeon confidence improved with increased experience and exposure. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Noninvasive referencing of intraocular tumors for external beam radiation therapy using optical coherence tomography: A proof of concept

    International Nuclear Information System (INIS)

    Rüegsegger, Michael B.; Steiner, Patrick; Kowal, Jens H.; Geiser, Dominik; Pica, Alessia; Aebersold, Daniel M.

    2014-01-01

    Purpose: External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). Methods: A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. Results: Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. Conclusions: The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors

  16. Phacoemulsification using iris hooks and scleral fixation of the intraocular lens in patients with secondary glaucoma associated with lens subluxation.

    Science.gov (United States)

    Ma, K T; Lee, H K; Seong, G J; Kim, C Y

    2008-09-01

    We described the techniques and results of phacoemulsification using iris hook and scleral fixation of intraocular lens (IOL) in patients with secondary glaucoma associated with lens subluxation. Eight eyes of seven patients with secondary glaucoma associated with lens dislocation, who had undergone the surgery, were retrospectively reviewed. At a mean of 23.5 months+/-13.6 (SD) after the surgery, the mean best-corrected visual acuity improved from 0.24+/-0.21 to 0.83+/-0.3, and mean intraocular pressure (IOP) was changed from 38.4+/-11.4 to 15.5+/-1.8 mmHg at the final examination. There were no vitreoretinal complications except cystoid macular oedema in one eye. The technique appears to be safe and effective in terms of visual rehabilitation and controlling IOP in patients with secondary glaucoma associated with lens subluxation.

  17. Comparison of intraocular pressure measurements with the portable PT100 noncontact tonometer and Goldmann applanation tonometry

    Directory of Open Access Journals (Sweden)

    Sarwat Salim

    2009-05-01

    Full Text Available Sarwat Salim, Daniel J Linn, James R Echols II, Peter A NetlandHamilton Eye Institute, University of Tennessee Health Science Center, Memphis, TN, USAPurpose: Noncontact tonometers are useful when regulations preclude use of contact tonometers by medical students and other nonophthalmologists. Our study compared the measurements by the portable, noncontact tonometer (PT100 with Goldmann applanation tonometry (GAT. Methods: This was a prospective study of 98 eyes from 98 patients. Intraocular pressure (IOP was measured by GAT and the PT100 (Reichert, Buffalo, NY.Results: Mean IOP measurements showed no significant differences in measurements performed by the two tonometers (P = 0.64. Measurements by the two tonometers were in agreement by ≤3 mmHg in 92.8% of eyes. Linear regression analysis of PT100 vs GAT measurements revealed a slope of 0.98 with r2 = 0.58. Bland–Altman analysis showed a mean difference of measurements by GAT and PT100 of -0.3 mmHg with two standard deviation = 7.1 mmHg.Conclusion: The portable noncontact PT100 tonometer provides IOP measurements comparable to GAT within the normal range of IOP. Keywords: applanation tonometer, intraocular pressure, noncontact tonometry

  18. Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract.

    Science.gov (United States)

    Fakhry, Mohamed A; El Shazly, Malak I

    2011-01-01

    To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium. Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt. Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre- and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3). Improvement in BCVA was statistically significant in both groups (P < 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P < 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P < 0.001). Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used.

  19. [Iris hooks and modified capsular tension ring for subluxation lens in patients with Marfan's syndrome].

    Science.gov (United States)

    Wu, Wen-Jie; Zheng, Dan-ying; Zheng, Ying-feng; Cai, Xiao-yu

    2007-02-01

    To evaluate clinical efficiency and safety of the iris hooks and modified capsular tension ring (MCTR) for the treatment of subluxation lens in patients with Marfan's syndrome. This study comprised 5 patients (7 eyes) with Marfan's syndrome and subluxation lens. After 3.2 mm clear cornea incision and continuous curvilinear capsulorhexis (CCC), 2 - 4 disposable nylon iris hooks were inserted through the stab incisions and placed in the capsulorhexis to support the capsule and enlarged the CCC. Following irrigation/aspiration, a MCTR with suture in its eyelet was placed in the capsule bag. After tightening and tying the suture of MCTR, the capsular bag was centered and fixed. A foldable AcrySof one-piece intraocular lens (IOL) was then placed in the capsule bag. Twelve months after the operation, the best corrected visual acuity was >/= 0.8 in six eyes and 0.7 in one eye. The scheimpflug images obtained from the Pentacam demonstrated that the IOL were well centered. UBM showed that all the MCTR and the haptics of the IOL were in the capsule bag, the eyelet of the MCTR was rested stably between the capsulorhexis margin and the iris. The retroillumination photograph indicated that only one eye had obvious posterior capsular opacification. No intraoperative and postoperative complications such as prolapse of vitreous and retina detachment was occurred. The iris hooks can provide excellent intraoperative capsule-lens stability and facilitate the manipulation during operation. MCTR allows additional suture fixation to the eye wall without damaging the capsular bag and maintains the long-term stability of the intraocular lens. Furthermore, MCTR is helpful for avoiding dislocation of the IOL due to progressive weakening of the zonular fibers in some patients and provides long-term safety.

  20. Biofilm Formation by Staphylococcus epidermidis on Foldable and Rigid Intraocular Lenses.

    Science.gov (United States)

    Fazly Bazzaz, Bibi Sedigheh; Jalalzadeh, Monireh; Sanati, Maryam; Zarei-Ghanavati, Syamak; Khameneh, Bahman

    2014-05-01

    Biofilm formation of Staphylococcus epidermidis is a major etiological factor of inducing device-related infections. The ability of biofilm formation by the S. epidermidis was assessed in vitro on two brands of foldable (hydrophilic) and two brands of rigid (hydrophobic) intraocular lens materials in order to investigate the role of lens material in postoperative endophthalmitis. To ensure reproducibility of biofilm formation on intraocular lenses, two strains of S. epidermidis and three quantification methods were performed. The S. epidermidis strains, DSMZ3270 (biofilm-producer) and ATCC12228 (non-biofilm-producer) were applied. Organisms were cultivated on disks of different brands of foldable hydrophilic Intra Ocular Lens (IOL) made of acrylic (Didar, Iran; (A) and Omni, India; (B)), and rigid hydrophobic IOL made of polymethyl methacrylate (PMMA; Didar, Iran; (C) and Hexavision, France; (D)). Biofilms were stained with crystal violet (CV) dye, which is an index of biofilm formation. The bacterial population was counted after biofilm homogenization. Scanning electron microscopy (SEM) was performed to examine the extent of biofilm formation. Adherence of DSMZ3270 strain on both types of foldable and rigid IOLs, was significantly more than ATCC12228 (P brands of foldable and PMMA IOLs. According to statistical analyses the incubation time influenced the biofilm formation on both types of IOLs which meant that by increasing incubation time, the biofilm formation increased. According to the SEM pictures, biofilm seems to be lysed at 72 hours. These data demonstrated that the attachment of bacteria to hydrophilic acrylic IOLs was more than hydrophobic PMMA ones independent of the brand. According to these results the bacterial strain might have more hydrophilic properties. Augmenting the biomass of biofilm by passing of time demonstrated the key role of time in biofilm formation on the IOL surfaces. The differences between IOL brands in the biofilm formation