WorldWideScience

Sample records for acremonium intraocular infection

  1. Acremonium kiliense infection in a child with chronic granulomatous disease

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Pastorino

    2005-12-01

    Full Text Available Infection by unusual microorganisms can be one of the clinical manifestations of primary immunodeficiency (PID. We report on a four-month-old child with pneumonia caused by the fungus Acremonium kiliense as the first clinical manifestation of chronic granulomatous disease. We emphasize the importance of an active search for unusual organisms in immunodeficient patients, and a precise diagnosis and early institution of specific treatment against such microorganisms for the reduction of the morbidity and mortality of these patients.

  2. Recurrent Acremonium infection in a kidney transplant patient treated with voriconazole: a case report Infecção recidivante por Acremonium em paciente transplantado renal tratado com voriconazol: relato de caso

    Directory of Open Access Journals (Sweden)

    Felipe Francisco Tuon

    2010-08-01

    Full Text Available Acremonium infection is rare and associated with immunosuppression. A case of recurrent cutaneous Acremonium infection after short term voriconazole use is described. Surgical resection was the definitive therapy. Oral voriconazole was used in the treatment of Acremonium infection, but recurrence was associated with short therapy. Prolonged antifungal therapy and surgical resection are discussed for the treatment of localized lesions.Infecção por Acremonium é rara e pode estar associada com imunossupressão. Descrevemos um caso de infecção recorrente de pele por Acremonium após tratamento breve com voriconazol. Ressecção cirúrgica foi o tratamento definitivo. Terapia prolongada com antifúngicos e ressecção cirúrgica são discutidas para o tratamento de doenças fúngicas localizadas.

  3. Modeling intraocular bacterial infections.

    Science.gov (United States)

    Astley, Roger A; Coburn, Phillip S; Parkunan, Salai Madhumathi; Callegan, Michelle C

    2016-09-01

    Bacterial endophthalmitis is an infection and inflammation of the posterior segment of the eye which can result in significant loss of visual acuity. Even with prompt antibiotic, anti-inflammatory and surgical intervention, vision and even the eye itself may be lost. For the past century, experimental animal models have been used to examine various aspects of the pathogenesis and pathophysiology of bacterial endophthalmitis, to further the development of anti-inflammatory treatment strategies, and to evaluate the pharmacokinetics and efficacies of antibiotics. Experimental models allow independent control of many parameters of infection and facilitate systematic examination of infection outcomes. While no single animal model perfectly reproduces the human pathology of bacterial endophthalmitis, investigators have successfully used these models to understand the infectious process and the host response, and have provided new information regarding therapeutic options for the treatment of bacterial endophthalmitis. This review highlights experimental animal models of endophthalmitis and correlates this information with the clinical setting. The goal is to identify knowledge gaps that may be addressed in future experimental and clinical studies focused on improvements in the therapeutic preservation of vision during and after this disease. PMID:27154427

  4. Catheter-Related Acremonium kiliense Fungemia in a Patient with Ulcerative Colitis under Treatment with Infliximab

    Directory of Open Access Journals (Sweden)

    Fernando A. Díaz-Couselo

    2011-01-01

    Full Text Available Acremonium spp. are filamentous, cosmopolitan fungi commonly isolated from plant debris and soil. They are infrequent pathogens in humans. Acremonium fungemia has been reported in neutropenic patients associated with central venous catheters and in nonneutropenic patients receiving long-term total parenteral nutrition. TNF-α blockade is associated with fungal infections, but no Acremonium spp. infection had been reported up to the present. In this paper, we present a patient with ulcerative colitis who developed Acremonium kiliense fungemia associated with infliximab therapy while receiving total parenteral nutrition. The patient was successfully treated with voriconazole. Acremonium sp. infection must be suspected as another cause of fungal infection in patients under treatment with infliximab.

  5. Onicomicosis por Acremonium Kiliense Onychomycosis by Acremonium Kiliense

    Directory of Open Access Journals (Sweden)

    M C Albrecht

    2007-03-01

    Full Text Available El rol de los hongos filamentosos hilalinos no dermatofitos, como agentes causales de onicomicosis, ha sido documentado en las últimas tres décadas por diferentes autores y son considerados oportunistas emergentes. El objetivo de este trabajo es presentar un caso de onicomicosis producido por Acremonium kiliense, cuya evolución fue estudiada. Se presentó al laboratorio de micología un paciente de 18 años de edad de sexo femenino con traumatismo en la uña del primer dedo del pie derecho. Se tomaron muestras seriadas de la lesión para la observación microscópica directa con OHK 40% p/v y para cultivos en Agar Sabouraud, Agar Lactrimel y DTM (medio selectivo para dermatofitos y con las colonias recuperadas se efectuaron microcultivos. Se implementó tratamiento con ciclopirox laca al 8% combinado al principio con Itraconazol vía oral (100 mg/día, con buena evolución. Es importante tener en cuenta a estos hongos oportunistas como agentes etiológicos potenciales de micosis ungueales, en especial en pacientes inmunodeprimidos, ya que la afección ungueal puede ser la puerta de entrada para la diseminación de la infección.The role of non-dermatophytic hyaline filamentous fungi as agents of onychomycosis has been documented in the last three decades by different authors, who have considered these fungi emerging opportunists. A 18-year-old female patient with trauma to the first toenail of the right foot came to the mycology laboratory. Serial samples of the lesion were collected for direct microscopic observation using 40% (w/v potassium hydroxide (KOH and for culture in Sabouraud agar, Lactrimel agar and DTM (dermatophyte selective medium. Microcultures were grown from the colonies recovered. Treatment with 8% ciclopirox nail lacquer, combined at the beginning with oral administration of itraconazole (100 mg a day, was implemented with good evolution. It is important to consider these opportunist fungi as potential etiological agents

  6. Intraocular infections in the neonatal intensive care unit

    Directory of Open Access Journals (Sweden)

    Sisk RA

    2012-05-01

    Full Text Available Hassan A Aziz1, Audina M Berrocal1,2, Robert A Sisk1, Kristin Hartley1, Magaly Diaz-Barbosa2, Rose A Johnson2, Ditte Hess1, Sander R Dubovy1, Timothy G Murray1, Harry W Flynn Jr11Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, 2Jackson Memorial Hospital, Miami, FL, USABackground: The purpose of this study was to report on the incidence and treatment outcomes of endogenous endophthalmitis among newborns in the neonatal intensive care unit (NICU of a single medical center.Methods: This was a noncomparative, retrospective case series of endogenous endophthalmitis among infants at the Jackson Memorial Hospital NICU treated between March 1, 2002 and March 1, 2007.Results: Of 4323 infants admitted to the NICU, seven eyes of six (0.139% infants (two males, four females were diagnosed with endophthalmitis during the study period. Four patients were born prematurely with a mean gestational age of 27.5 weeks and a mean birth weight of 1153 g. Retinopathy of prematurity was reported in two of the six patients. Mean follow-up was 3.5 years. The diagnosis was confirmed by positive cultures or polymerase chain reaction testing at a median age of 34 postnatal days. Positive cultures included Candida albicans (n = 4, Pseudomonas aeruginosa (n = 1, and Herpes simplex type 2 (n = 1. All patients received systemic treatment and five received adjunctive ophthalmic interventions, including intravitreal antibiotics in five eyes of four patients and vitrectomy with pars plana lensectomy in three eyes. One patient underwent primary enucleation and another had delayed evisceration. In the remaining five eyes, there was a normal appearing posterior segment and normal intraocular pressures at last follow-up.Conclusion: Endogenous endophthalmitis is a rare complication in infants in the NICU, but may occur in patients with candidemia, bacteremia, retinopathy of prematurity, and low birth weight. Despite early and

  7. Role of intraocular Leptospira infections in the pathogenesis of Equine Recurrent Uveitis in the Southern United States

    Science.gov (United States)

    To investigate the role of intraocular leptospiral infections in horses with Equine Recurrent Uveitis (ERU) in the southern United States, blood and ocular fluid samples were collected from horses with a history and ocular findings consistent with ERU. Samples were also obtained from control horses ...

  8. Experimental intraocular infection of exotic cockerels with field strain of velogenic Newcastle disease virus in Nigeria

    Directory of Open Access Journals (Sweden)

    Samaila Jonathan Badau

    2015-12-01

    Full Text Available Experimental intraocular (conjunctival infection of exotic cockerels with a new field strain of viscerotropic velogenic Newcastle Disease Virus (NDV was conducted to explore the concurrence of some pathological changes with humoral immune responses. After the NDV infection of 4-week-old cockerels, pathologic changes and antibody responses were observed. The clinical signs observed after the artificial inoculation included inappetence, depression, diarrhea, dyspnea, wing and leg paralysis, torticollis and weight loss. Morbidity due to the NDV was 100%, but mortality was 80% by day 18-21 post-infection. Early hyperthermia followed by terminal hypothermia, decreased packed cell volume (PCV, and 231.4 folds peak-antibody response were observed. Necrotic and/or inflammatory lesions were present in the proventriculus, intestine, liver, spleen, kidney and brain. Neurologic and digestive tract perturbations occurred in 10% and 85% of cases, respectively. The disease consistently caused stunted growth, decreased PCV, and necro-inflammatroy lesions concurrent with antibody response, suggesting probable involvement of immune-mediated mechanisms and cell membrane desialylation by viral neuraminidase in the pathogenesis.

  9. Acremonium with catenate elongate conidia : phylogeny of Acremonium fusidioides and related species

    NARCIS (Netherlands)

    Giraldo Lopez, Dixie Alejandra; Gené, Josepa; Cano, Josep; de Hoog, G Sybren; Decock, Cony Antonio; Guarro, Josep

    2014-01-01

    Acremonium is one of the largest and most complex genera of hyphomycetes. Its taxonomy is not yet resolved and the phylogenetic value of the most distinctive morphological features is unknown. The species of this genus produce conidia in chains or form slimy heads or both. We have studied a set of c

  10. Entomopathogenic Potential of Verticillium and Acremonium Species (Deuteromycotina: Hyphomycetes)

    DEFF Research Database (Denmark)

    Steenberg, Tove; Humber, Richard A

    1999-01-01

    entomopathogen. The fungi were identified as Verticillium fusisporum, Veritcillium psalliotae, Verticillium lamellicola, and species of Acremonium. Isolates of these fungi were bioassayed against the sweet-potato whitefly (Bemisia tabaci) and against the housefly (Musca domestica) to examine....... In general, V. lecanii was the most pathogenic species. Immature whiteflies appeared to be more susceptible to fungal infection than adult houseflies, and the host range for several of the fungi also included lesser mealworm....

  11. Bacterial endophthalmitis in the age of outpatient intravitreal therapies and cataract surgeries: host-microbe interactions in intraocular infection.

    Science.gov (United States)

    Sadaka, Ama; Durand, Marlene L; Gilmore, Michael S

    2012-07-01

    Bacterial endophthalmitis is a sight threatening infection of the interior structures of the eye. Incidence in the US has increased in recent years, which appears to be related to procedures being performed on an aging population. The advent of outpatient intravitreal therapy for management of age-related macular degeneration raises yet additional risks. Compounding the problem is the continuing progression of antibiotic resistance. Visual prognosis for endophthalmitis depends on the virulence of the causative organism, the severity of intraocular inflammation, and the timeliness of effective therapy. We review the current understanding of the pathogenesis of bacterial endophthalmitis, highlighting opportunities for the development of improved therapeutics and preventive strategies. PMID:22521570

  12. Characterization of Acremonium and Isaria ice nuclei

    Science.gov (United States)

    Pummer, Bernhard G.; Pöschl, Ulrich; Fröhlich-Nowoisky, Janine

    2014-05-01

    Until recently, the only known fungal ice nuclei (IN) were a few exponents of lichen mycobionts and Fusarium spp. [Kieft and Ruscetti 1990, Pouleur et al. 1992, Hasegawa et al. 1994, Tsumuki et al. 1995], as well as two strains of mold [Jayaweera and Flanagan 1982]. Other investigated species did not show any IN activity [Pouleur et al. 1992, Iannone et al. 2011, Pummer et al. 2013]. In the last few years, IN-activity has been discovered in some rust and smut fungi [Morris et al. 2013, Haga et al. 2013], Acremonium implicatum (Acr.) and Isaria farinosa (Isa.) [Huffman et al. 2013] and a handful of other airborne and soil fungi [unpublished data]. We started characterizing the IN of Acr. and Isa.: Like other non-bacterial biological IN, they can be easily separated from the cells in aqueous suspension, and keep their activity. The IN-active aqueous suspensions were processed by filtration (5 μm, 0.1 μm, 300 kDa, 100 kDa) and exposure to heat (60° C) or guanidinium chloride (6 M). The IN activity of the processed samples was measured by a freezing assay of droplets, as described by Pummer et al. [2013]. Via the Vali formula, we calculated the amount of IN per gram of mycelium, which is higher than 105 g-1. The initial freezing temperature was -4° C for Isaria and -8° C for Acremonium IN. Both were completely knocked out by 60° C or guanidinium chloride. The Acremonium IN are in a mass range between 100 and 300 kDa. The Isaria IN seem to be either a bit larger, or more attached to larger particles, since not all of them pass through the 300-kDa-filter. It is likely that both of these new IN are proteinaceous like the IN of Fusarium spp. and lichen mycobionts, which belong to the Ascomycota phylum. Since the Isaria IN show a high onset freezing temperature and are rather large for single molecules, they might be agglomerates. Haga D.I. et al. (2013) J. Geophys. Res.: Atm. 118, 7260-7272 Hasegawa Y. et al. (1994) Biosci. Biotech. Biochem. 58, 2273-2274 Huffman A

  13. Entomopathogenic potential of Verticillium and Acremonium species (Deuteromycotina: Hyphomycetes).

    Science.gov (United States)

    Steenberg, T; Humber, R A

    1999-05-01

    Hyphomycetes with conidia formed in slimy heads from hyaline mycelium were isolated from a range of insect hosts. Isolation on artificial medium and microscopic examination revealed that these fungi in many cases were not Verticillium lecanii despite a superficial resemblance to this common entomopathogen. The fungi were identified as Verticillium fusisporum, Verticillium psalliotae, Verticillium lamellicola, and species of Acremonium. Isolates of these fungi were bioassayed against the sweet-potato whitefly (Bemisia tabaci) and against the housefly (Musca domestica) to examine their entomopathogenicity. A test was also conducted with a coleopteran (lesser mealworm, Alphitobius diaperinus) to further evaluate the host range for some of the fungi. V. lamellicola was not pathogenic to the two species of insects treated, while varying levels of pathogenicity were shown for the other species. In general, V. lecanii was the most pathogenic species. Immature whiteflies appeared to be more susceptible to fungal infection than adult houseflies, and the host range for several of the fungi also included lesser mealworm. PMID:10222186

  14. Clinical experiences in fungal keratitis caused by Acremonium

    Directory of Open Access Journals (Sweden)

    Kim SJ

    2014-01-01

    Full Text Available Seong-Jae Kim,1,2 Yong-Wun Cho,1 Seong-Wook Seo,1,2 Sun-Joo Kim,2,3 Ji-Myong Yoo1,21Department of Ophthalmology, 2Gyeongsang Institute of Health Science, 3Department of Laboratory Medicine, Gyeongsang National University, College of Medicine, Jinju, KoreaPurpose: To report the predisposing risk factors, clinical presentation, management, and therapeutic outcomes of fungal keratitis caused by Acremonium.Methods: This is a retrospective study of cases with Acremonium fungal keratitis that presented to our tertiary referral center between January 2006 and August 2012. Patient demographic and clinical details were determined and reported.Results: Five cases of fungal keratitis from Acremonium species were identified in five patients (three males, two females. The mean age of the patients was of 73.4±5.46 years, with a mean follow-up time of 124±72 days. All patients had a history of corneal trauma with vegetable matter. Four cases were unresponsive to initial treatment (0.2% fluconazole, 0.15% amphotericin B and required topical 5% natamycin, and, in two out of five cases, topical 1% voriconazole.Conclusion: The most common risk factors for Acremonium fungal keratitis was ocular trauma. When a corneal lesion is found to be unresponsive to the initial treatment, we should consider adding or substituting topical natamycin or voriconazole for treatment.Keywords: Acremonium, fungal keratitis, natamycin, prognosis, voriconazole

  15. Cellulases and hemicellulases from endophytic Acremonium species and its application on sugarcane bagasse hydrolysis

    Science.gov (United States)

    The aim of this work was to have cellulase activity and hemicellulase activity screenings of endophyte Acremonium species (Acremonium zeae EA0802 and Acremonium sp. EA0810). Both fungi were cultivated in submerged culture (SC) containing L-arabinose, D-xylose, oat spelt xylan, sugarcane bagasse, or...

  16. Extracellular Hemicellulolytic Enzymes from the Maize Endophyte Acremonium zeae

    Science.gov (United States)

    The maize endophyte Acremonium zeae was examined for production of extracellular enzymes that hydrolyze cellulose and hemicellulose. The most prominent enzyme activity in cell-free culture media from A. zeae NRRL 6415 was xylanase, with a specific activity of 60 U/mg from cultures grown on crude co...

  17. [Tropical ophthalmology : Intraocular inflammation caused by "new" infectious pathogens and travel-related infections].

    Science.gov (United States)

    Pleyer, U; Klauß, V; Wilking, H; Nentwich, M M

    2016-01-01

    A number of "new" (emerging) infections that can also cause inflammatory eye changes are appearing and becoming increasingly important. In the past, diseases such as chikungunya, dengue fever or West Nile virus infections were endemic in tropical regions, but are now expanding worldwide and causing significant morbidity and even mortality. "Globalization" and human migration are important factors leading to the import of these infections. Climate changes are probably even more important. Increasing temperatures provide suitable conditions for new vectors, and may lead to autochthonous transmission of infectious pathogens. Diagnosis of these diseases requires not only careful assessment of medical and travel history, but also the application of specific laboratory diagnostic tests. A broad spectrum of ocular involvement has been reported, with frequent posterior segment involvement. Emerging infections should therefore be considered in the differential diagnosis of retinitis, chorioretinitis, retinal vasculitis and optic neuropathy in a patient living in or traveling back from an endemic area. Since these infections are often vector (insect) borne and effective treatments are almost uniformly lacking, prevention is at least as important as prompt diagnosis and initiation of supportive care. Here, we focus on Chikungunya, Dengue fever, Ebola fever, the West Nile virus and Rickettsioses, which frequently demonstrate ocular involvement. PMID:26649438

  18. Transmissibilidade e efeito de Acremonium strictum em sementes de milho Transmissibility and effect of Acremonium strictum in maize seeds

    Directory of Open Access Journals (Sweden)

    Hudson Teixeira

    2003-10-01

    Full Text Available Acremonium strictum é patogênico ao milho e a outras culturas, podendo causar podridão de sementes, podridão de colmos e a morte de plântulas. Trata-se de um fungo que pode interferir no vigor, estande e produtividade final das plantas. Além disso, pode ser disseminado e transmitido à progênie via sementes, ainda que não sejam conhecidas as proporções reais em que isso ocorre. Neste trabalho, avaliou-se o efeito de A. strictum nas qualidades fisiológica e sanitária de sementes e plântulas, no crescimento vegetativo e na sanidade (taxas de infecção e de transmissão de plantas de milho em seu estádio inicial de desenvolvimento. As taxas de infecção e de transmissão do fungo foram avaliadas usando-se a técnica da restrição hídrica, previamente desenvolvida para infectar as sementes. O meio MA (extrato de malte-ágar, suplementado com manitol para obter o potencial de água de -1,4 MPa, foi o substrato utilizado na inoculação das sementes. Observou-se que a germinação das sementes de milho foi reduzida por A. strictum em períodos de contato com a colônia fúngica acima de 72 horas. O vigor e a viabilidade potenciais das sementes de milho não foram afetados pela presença de A. strictum. Após 28 dias da semeadura, a incidência de A. strictum reduziu o crescimento vegetativo de plantas de milho. O fungo A. strictum, oriundo de sementes inoculadas, foi transmitido às plantas jovens de milho.Acremonium strictum is pathogenic to seeds, stalk and seedlings of maize. It is a fungus that can interfere in the vigor, stand and final productivity of plants. In addition, it can be disseminated and transmitted through seeds to the progeny, although the real proportions of that are not well known. This study reports the effects of A. strictum on maize seeds and seedlings quality (germination, vigor, healthness, some vegetative growth parameters and also sanity (infection and transmission rates of young maize plants. The

  19. The complete mitochondrial genome of the nematophagous fungus Acremonium implicatum.

    Science.gov (United States)

    Yao, Yurong; Lin, Runmao; Tian, Xueliang; Shen, Baoming; Mao, Zhenchuan; Xie, Bingyan

    2016-09-01

    The complete mitochondrial genome of the nematophagous fungus Acremonium implicatum is reported for the first time. The genome is concatenated with 22,367 bp in length, encoding 13 protein-coding genes, 2 ribosomal RNA genes and a set of 17 transfer RNA genes. The synteny analysis reveals that 50.35% of A. implicatum mitochondrial sequences matched to 48.21% of Acremonium chrysogenum mitochondrial sequences with 85.68% identity. Two proteins of cox3 and nad6, as well as seven tRNAs are lost in A. implicatum mitogenome compared to A. chrysogenum mitogenome. The gene orders in A. implicatum and A. chrysogenum mitogenome is different, which is mainly due to the location of nad4 and cox2. In addition, one transposition event related to tRNAs is identified in these two mitogenomes. This study may provide valuable mitochondrial information for research on A. implicatum and facilitate the study of mitochondrial evolution. PMID:25630733

  20. Effects of the fungal endophyte Acremonium coenophialum on nitrogen accumulation and metabolism in tall fescue

    International Nuclear Information System (INIS)

    Infection by the fungal endophyte Acremonium coenophialum affected the accumulation of inorganic and organic N in leaf blades and leaf sheaths of KY31 tall fescue (Festuca arundinacea Schreb.) grown under greenhouse conditions. Total soluble amino acid concentrations were increased in either the blade or sheath of the leaf from infected plants. A number of amino acids were significantly increased in the sheath, but only asparagine increased in the blade. Infection resulted in higher sheath NH4+ concentrations, whereas NO3- concentrations decreased in both leaf parts. The effects on amino acid, NO3-, and NH4+ concentrations were dependent upon the level of N fertilization and were usually apparent only at the high rate (10 millimolar) of application. Administration of 14CO2 to the leaf blades increased the accumulation of 14C in their amino acid fraction but not in the sheaths of infected plants. This may indicate that infection increased amino acid synthesis in the blade but that translocation to the sheath, which is the site of fungal colonization, was not affected. Glutamine synthetase activity was greater in leaf blades of infected plants at high and low N rates of fertilization, but nitrate reductase activity was not affected in either part of the leaf. Increased activities of glutamine synthetase together with the other observed changes in N accumulation and metabolism in endophyte-infected tall fescue suggest that NH4+ reassimilation could also be affected in the leaf blade

  1. Interference by methionine on valine uptake in Acremonium chrysogenum.

    OpenAIRE

    Alonso, M J; Luengo, J M

    1987-01-01

    The incorporation of L-[U-14C]valine into delta-(L-alpha-aminoadipyl)-L-cysteinyl-D-valine (ACV), a direct biosynthetic precursor of penicillins and cephalosporins, was studied. When DL-methionine was added to Acremonium chrysogenum culture broths, no labeled ACV was found, while a large amount of radioactive ACV was detected when methionine was not present. DL-Norleucine, a nonsulfur analog of methionine, also inhibited the synthesis of radioactive ACV to some degree. This effect was due to ...

  2. Antimicrobial activity of pyrrocidines from Acremonium zeae against endophytes and pathogens of maize.

    Science.gov (United States)

    Wicklow, Donald T; Poling, Stephen M

    2009-01-01

    Acremonium zeae produces pyrrocidines A and B, which are polyketide-amino acid-derived antibiotics, and is recognized as a seedborne protective endophyte of maize which augments host defenses against microbial pathogens causing seedling blights and stalk rots. Pyrrocidine A displayed significant in vitro activity against Aspergillus flavus and Fusarium verticillioides in assays performed using conidia as inoculum, with pyrrocidine A being more active than B. In equivalent assays performed with conidia or hyphal cells as inoculum, pyrrocidine A revealed potent activity against major stalk and ear rot pathogens of maize, including F. graminearum, Nigrospora oryzae, Stenocarpella (Diplodia) maydis, and Rhizoctonia zeae. Pyrrocidine A displayed significant activity against seed-rotting saprophytes A. flavus and Eupenicillium ochrosalmoneum, as well as seed-infecting colonists of the phylloplane Alternaria alternata, Cladosporium cladosporioides, and Curvularia lunata, which produces a damaging leaf spot disease. Protective endophytes, including mycoparasites which grow asymptomatically within healthy maize tissues, show little sensitivity to pyrrocidines. Pyrrocidine A also exhibited potent activity against Clavibacter michiganense subsp. nebraskense, causal agent of Goss's bacterial wilt of maize, and Bacillus mojaviense and Pseudomonas fluorescens, maize endophytes applied as biocontrol agents, but were ineffective against the wilt-producing bacterium Pantoea stewartii. PMID:19055442

  3. Effects of the endophyte Acremonium alternatum on oilseed rape (Brassica napus development and clubroot progression

    Directory of Open Access Journals (Sweden)

    SUSANN AUER

    2014-06-01

    Full Text Available The clubroot pathogen Plasmodiophora brassicae infects economically important Brassica crops such as oilseed rape and vegetable brassicas. Clubroot results in abnormally growing roots and restricts the flow of water and nutrients to the upper plant parts, thereby inducing wilting. Yield loss affects about half the percentage of infected plants. Due to its complex and well-adapted life cycle the pathogen is difficult to control by chemical and cultural means and therefore continues to spread around the globe. Infested fields can no longer be used effectively for cultivation of crop plants for at least the next ten years. Despite costly breeding of resistant cultivars, recent research leans towards alternative, low-impact and environmentally friendly methods to control clubroot. To this end we have previously identified the endophyte Acremonium alternatum, a known biological control agent in several countries, to show promising antagonistic effects in clubroot-infected A. thaliana and Chinese cabbage (Brassica rapa. Here, we will describe its effect on the growth, development and clubroot control of oilseed rape (Brassica napus. While the clubroot symptoms were not clearly reduced after co-inoculation with A. alternatum and P. brassicae on oilseed rape roots, the aboveground plant parts were delayed in senescence and produced more seeds, which is indicative of an increase in yield after A. alternatum treatment. The long-term goal of this work is to contribute to a fundamental understanding of endophyte-plant interactions and an effective reduction of clubroot to be used in integrated pest management for oilseed rape and other cabbage varieties.

  4. Bacterial endophthalmitis in the age of outpatient intravitreal therapies and cataract surgeries: Host-microbe interactions in intraocular infection

    OpenAIRE

    Sadaka, Ama; Durand, Marlene L.; Gilmore, Michael S.

    2012-01-01

    Bacterial endophthalmitis is a sight threatening infection of the interior structures of the eye. Incidence in the US has increased in recent years, which appears to be related to procedures being performed on an aging population. The advent of outpatient intravitreal therapy for management of age-related macular degeneration raises yet additional risks. Compounding the problem is the continuing progression of antibiotic resistance. Visual prognosis for endophthalmitis depends on the virulenc...

  5. Bilateral Primary Intraocular Lymphoma

    Directory of Open Access Journals (Sweden)

    Mehrdad Karimi

    2011-01-01

    Full Text Available Purpose: To report a case of bilateral primary intraocular lymphoma. Case report: A 33-year-old man presented with bilateral blurred vision since two years ago. Examination revealed large keratic precipitates, anterior chamber reaction, posterior subcapsular cataracts, and vitreous infiltration. After a short trial of topical and periocular steroids, diagnostic 25-gauge pars plana vitrectomy was performed and cytologic evaluation of the aspirate confirmed a diagnosis of intraocular lymphoma. The patient was subsequently managed with intravitreal methotrexate in both eyes and responded favorably. Central nervous system workup for lymphoma was negative. Conclusion: Primary intraocular lymphoma should be considered in young adults suffering from chronic recalcitrant panuveitis.

  6. Effect of simulated acid rain on the mutualism between tall fescue (Festuca arundinacea) and an endophytic fungus (Acremonium coenophialum)

    Energy Technology Data Exchange (ETDEWEB)

    Cheplick, G.P. (Univ. of Wisconsin, Whitewater (United States))

    1993-03-01

    Biotic interactions between plants and microorganisms have the potential to be affected by acidic precipitation. I examined the effect of simulated sulfuric acid rain on the mutualism between a perennial forage grass (Festuca arundinacea) and a fungal endophyte (Acremonium coenophialum). Acid water was supplied as mists sprayed onto leaf surfaces or as water added to the soil for two groups in a greenhouse: one group had high levels of endophyte infection, while the other was predominantly noninfected. Control plants received distilled water (pH 6), while others received sulfuric acid water at pH 4.5 or pH 3. Plants were harvested after 4, 6, 8, and 23 wk. Leaf endophyte infection intensity as measured by hyphal counts was not affected by acid water treatment. Root mass and root: shoot ratios generally decreased with increasing acidity of both foliar sprays and soil water, but shoot mass was mostly not affected. There was a significant pH x infection interaction for plants exposed to acidic foliar sprays for 4 wk; root and shoot mass decreased with acidity, but only for infected plants. It was found that acid rain may be deleterious to tall fescue growth at specific stages of development, but biomass production in response to acid rain is not likely to be influenced by fungal endophytes within mature plants. 55 refs., 2 figs., 3 tabs.

  7. Regulation of the Cyanide-Resistant Alternative Respiratory Pathway in the Fungus Acremonium chrysogenum

    OpenAIRE

    Sándor, Erzsébet; Fekete, Erzsébet; Karaffa, Levente

    2003-01-01

    This review summarises the current knowledge on the biochemical and physiological events that directly or indirectly alter the engagement of the cyanide-resistant alternative respiratory pathway in the cephalosporin C producer filamentous fungus Acremonium chrysogenum. Particular emphasis is placed on the role this activity plays in the overproduction of antibiotic, and also on the critical fermentation technology background that supports its operation.

  8. Bilateral Primary Intraocular Lymphoma

    OpenAIRE

    Mehrdad Karimi; Masoud Soheilian; Mozhgan Rezaei Kanavi

    2011-01-01

    Purpose: To report a case of bilateral primary intraocular lymphoma. Case report: A 33-year-old man presented with bilateral blurred vision since two years ago. Examination revealed large keratic precipitates, anterior chamber reaction, posterior subcapsular cataracts, and vitreous infiltration. After a short trial of topical and periocular steroids, diagnostic 25-gauge pars plana vitrectomy was performed and cytologic evaluation of the aspirate confirmed a diagnosis of intraocular lympho...

  9. Bilateral intraocular dirofilariasis

    Directory of Open Access Journals (Sweden)

    Viney Gupta

    2014-01-01

    Full Text Available Ocular dirofilariasis mostly presents as a subconjunctival or eyelid lesion. [1] Intraocular dirofilarial infestation is rare. [2],[3] We report a case of a young woman who was accidentally detected to have a live motile worm in the anterior segment in one eye and a cystic lesion on the optic disc in the other eye. To our knowledge, bilateral intraocular dirofilariasis has never been reported.

  10. Viabilidade, confirmação taxonômica e detecção enzimática de espécies de Acremonium preservadas sob óleo mineral na Coleção de Culturas University Recife Mycology Viability, taxonomic confirmation and enzymatic detection of Acremonium species preserved under mineral oil in the URM Culture Collection

    Directory of Open Access Journals (Sweden)

    Suellen Carvalho de Moura Braz

    2009-02-01

    Full Text Available Enzimas hidrolíticas secretadas por fungos têm um papel importante na patogenicidade das infecções. Objetivando avaliar a atividade enzimática foram testados 31 isolados de Acremonium mantidos na Coleção de Culturas University Recife Mycology. Fragmentos das culturas foram transferidos para caldo glicosado para reativação e posterior crescimento em meio ágar batata dextrose, para verificar viabilidade, pureza e confirmação taxonômica pela observação das características macroscópicas e microscópicas. Para detecção enzimática foram utilizados substratos de caseína do leite e gelatina para protease, amido para amilase e lecitina de soja para fosfolipase. Das 31 culturas, 26 (83,9% mantiveram-se viáveis e 24 (92,3% foram confirmadas taxonomicamente. Das 24 culturas, 12 (50% apresentaram atividade proteásica, duas (16,7% em caseína do leite, uma (8,3% em gelatina e nove (75% em ambos os substratos; 16 (66,7% degradaram amido. Nenhuma cultura apresentou atividade fosfolipásica. Conclui-se que espécies de Acremonium são capazes de produzir enzimas envolvidas na patogenicidade das infecções fúngicas.Hydrolytic enzymes secreted by fungi play an important role in the pathogenesis of infection. With the aim of evaluating the enzymatic activity, 31 isolates of Acremonium stored in the University of Recife Mycology (URM Culture Collection were tested. Culture fragments were transferred to glycoside broth for reactivation and further growth in potato dextrose agar medium in order to investigate viability and purity and to confirm the taxonomy through observing the macroscopic and microscopic characteristics. To detect enzymes, milk casein and gelatin were used as substrates for proteinase, starch for amylase and soy lecithin for phospholipase. Among the 31 cultures, 26 (83.9% remained viable and 24 (92.3% were confirmed taxonomically. Out of these 24 cultures, 12 (50% presented proteinase activity, of which two (16.7% were on

  11. Intraocular Gnathostomiasis: Report of a Case and Review of Literature

    OpenAIRE

    Pillai, Gopal S.; Kumar, Anil; Radhakrishnan, Natasha; Maniyelil, Jayasree; Shafi, Tufela; Dinesh, Kavitha R.; Karim, Shamsul

    2012-01-01

    Intraocular gnathostomiasis is a rare parasitic infection caused by the third-stage larvae of spiruroid nematode Gnanthostoma spp. seen mostly in tropical and subtropical regions. It is a food-borne zoonosis caused by ingestion of raw or undercooked freshwater fish, amphibians, reptiles, birds, and mammals, all of which are known to harbor advanced third-stage larvae of Gnanthostoma spp. To date, 74 cases of intraocular gnathostomiasis have been reported from 12 different countries. Only four...

  12. Cyclosporin C is the main antifungal compound produced by Acremonium luzulae.

    OpenAIRE

    Moussaïf, M; Jacques, P.; Schaarwächter, P; Budzikiewicz, H.; Thonart, P.

    1997-01-01

    A strain of Acremonium luzulae (Fuckel) W. Gams was selected in screening new microorganisms for biological control of fruit postharvest diseases, especially gray and blue mold diseases on apples and strawberries. This strain manifests a very strong activity against a large number of phytopathogenic fungi. In this work, the product responsible for this antifungal activity was isolated from modified Sabouraud dextrose broth cultures of A. luzulae. It was purified to homogeneity by reverse-phas...

  13. Crystal Structure of Talaromyces cellulolyticus (Formerly Known as Acremonium cellulolyticus) GH Family 11 Xylanase

    OpenAIRE

    Kataoka, Misumi; Akita, Fusamichi; Maeno, Yuka; Inoue, Benchaporn; Inoue, Hiroyuki; Ishikawa, Kazuhiko

    2014-01-01

    Talaromyces cellulolyticus (formerly known as Acremonium cellulolyticus) is one of the mesophilic fungi that can produce high levels of cellulose-related enzymes and are expected to be used for the degradation of polysaccharide biomass. In silico analysis of the genome sequence of T. cellulolyticus detected seven open reading frames (ORFs) showing homology to xylanases from glycoside hydrolase (GH) family 11. The gene encoding the GH11 xylanase C (TcXylC) with the highest activity was used fo...

  14. Environmental standards for intraocular lens implantation.

    Science.gov (United States)

    Crawford, B A; Kaufman, D V

    1984-02-01

    Successful implantation of prosthetic devices depends upon their freedom from postoperative inflammation and infection. Techniques and lessons learned in orthopaedic and other implant surgery should be applied to intraocular lens implantation. The avoidance of contamination by particles and micro-organisms is one essential principle of the surgical procedure. Practical steps are described to reduce both types of contamination. These measures taken together are recommended for adoption as a standard of environmental safety for lens implantation.

  15. Opaque intraocular lens implantation

    OpenAIRE

    Yusuf IH; Patel CK

    2013-01-01

    Imran H Yusuf, CK Patel The Oxford Eye Hospital, West Wing, John Radcliffe Hospital, Headley Way, Headington, Oxford, United KingdomWe read with great interest the recent article by Lee et al,1 who described their clinical experience with three patients who underwent primary implantation of Morcher (Stuttgart, Germany) occlusive intraocular lenses (IOLs) across a variety of neuro-ophthalmic indications. We hope to offer some further insight into these clinical observations in the context of o...

  16. claw intraocular lens

    OpenAIRE

    Gonnermann, Johannes

    2015-01-01

    There is a wide range of alternative fixation techniques of intraocular lenses in the absence of adequate capsular support, such as angle- or iris-supported anterior chamber lenses and intra- / transsclerally-fixated (suture, fibrin glue, etc.) and iris-supported posterior chamber lenses. All procedures have different advantages and disadvantages depending on the anatomical situation and integrity of the capsular bag complex and the neighboring structures such as the iris, sclera and corneal ...

  17. Phakic Intraocular lens- a review

    OpenAIRE

    Cruz, Francisco Miguel

    2015-01-01

    Introduction: Intraocular refractive procedures with the implantation of a Phakic Intraocular lens have become a safe efficient and predictable alternative for treating high ametropias when the use of corneal photoablative procedures is not possible. The implantation of Phakic intraocular lens preservs the accomodative function,is a reversable refractive procedure, with minimal induction of higher order aberrations compaed with corneal photoablative procedures. Methods: An analytical review o...

  18. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  19. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  20. Isolation of Antioxidant Compound from Endophytic Fungi Acremonium sp. from the Twigs of Kandis Gajah

    Directory of Open Access Journals (Sweden)

    Rizki

    2012-04-01

    Full Text Available The endophytic fungi Chrisonilia sitophila, Acremonium sp., and Penicillium sp. have been isolated from the tissues ofthe twigs of kandis gajah. All of the fungi strains were grown in 3 L potatoe dextrose broth medium (PDB at a roomtemperature for 28 days. To extract the antioxidant compounds, the culture broth were filtered for mycelia removalfollowed by extraction and evaporation. All of the extracts were evaluated for their antioxidant activities by using 1,1-diphenyl-2-picrylhydrazyl (DPPH radical scavenging activity. The extract of Acremonium sp. have strong activity withIC50 value of 10.3 μg/mL, which is equivalent to ascorbic acid activity with IC50 value of 9.8 μg/mL. The extract wassubjected to column chromatography on Si gel twice to obtain a high purity antioxidant compound in the form of yellowoil. The molecular structure was determined based on spectroscopic data, including 1H-NMR, 13C-NMR, HMQC,HMBC, and COSY. The compound was determined as sesquiterpene 3,5-dihydroxy-2,5-dimethyltrideca-2,9,11-triene-4,8-dione.

  1. A Battle in a Kernel: Molecular Exploration of Antagonisms between Two Maize Endophytes, Fusarium verticillioides and Acremonium zeae

    Science.gov (United States)

    Fusarium verticillioides (Fv) is a prevalent seed-borne maize endophyte capable of causing severe kernel rot and fumonisin mycotoxin contamination. Within maize kernels, Fv is primarily confined to the pedicel, while another seed-borne fungal endophyte, Acremonium zeae (Az), is observed in embryos. ...

  2. Drug-Eluting Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Angel Concheiro

    2011-11-01

    Full Text Available Notable advances in materials science and in surgical techniques make the management of cataract by replacement of the opaque crystalline with an intraocular lens (IOL, one of the most cost-effective interventions in current healthcare. The usefulness and safety of IOLs can be enhanced if they are endowed with the ability to load and to sustain drug release in the implantation site. Drug-eluting IOLs can prevent infections and untoward reactions of eye tissues (which lead to opacification and also can act as drug depots for treatment of several other ocular pathologies. Such a myriad of therapeutic possibilities has prompted the design of drug-IOL combination products. Several approaches are under study, namely combination of the IOL with an insert in a single device, soaking in drug solutions, impregnation using supercritical fluids, coating with drug/polymer layers, and covalent grafting of the drug. The advantages/limitations of each technique are discussed in the present review on selected examples. Although more in vivo data are required, the information already available proves the interest of some approaches in ocular therapeutics.

  3. Intraocular coenurosis: a case report.

    OpenAIRE

    Ibechukwu, B. I.; Onwukeme, K. E.

    1991-01-01

    A case of intraocular coenurosis was clinically diagnosed and treated with praziquantel. The drug destroyed the coenurus, but vision was lost through toxic endophthalmitis and retinal detachment. There were no systemic side effects.

  4. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials...

  5. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  6. Structural elucidation of XR586, a peptaibol-like antibiotic from Acremonium persicinum.

    Science.gov (United States)

    Sharman, G J; Try, A C; Williams, D H; Ainsworth, A M; Beneyto, R; Gibson, T M; McNicholas, C; Renno, D V; Robinson, N; Wood, K A; Wrigley, S K

    1996-12-15

    A novel peptide, XR586, has been isolated from fermentations of Acremonium persicinum (Xenova culture collection number X21488). The structure of XR586 has been elucidated by means of NMR spectroscopy, electrospray and fast-atom bombardment MS, derivatization and enzymic digestion. It has been shown to be helical by CD measurements. XR586 shows many structural and conformational features in common with peptaibols, particularly the zervamicins. Peptaibol antibiotics are peptides, typically of 15-20 residues, containing a large proportion of alpha-aminoisobutyric acid (Aib) residues. These peptides adopt a helical conformation in solution and display anti-bacterial and toxic properties due to their ability to form pores in membranes. However, while XR586 contains several Aib residues, it lacks a terminal phenylalaninol and terminates in the sequence Phe-Gly. The lack of reduction of the penultimate residue at the C-terminus may indicate that this step is normally at the end of the biosynthetic pathway of peptaibols and occurs with cleavage of Gly. The 1H chemical shift assignments of XR586 are reported in Supplementary Publication SUP 50179 (3 pages), which has been deposited at the British Library Document Supply Centre, Boston Spa, Wetherby, West Yorkshire LS23 7BQ, U.K., from whom copies can be obtained on the terms indicated in Biochem. J. (1996) 313, 9 ("Deposition of data'). PMID:9003355

  7. Crystal structure of Talaromyces cellulolyticus (formerly known as Acremonium cellulolyticus) GH family 11 xylanase.

    Science.gov (United States)

    Kataoka, Misumi; Akita, Fusamichi; Maeno, Yuka; Inoue, Benchaporn; Inoue, Hiroyuki; Ishikawa, Kazuhiko

    2014-10-01

    Talaromyces cellulolyticus (formerly known as Acremonium cellulolyticus) is one of the mesophilic fungi that can produce high levels of cellulose-related enzymes and are expected to be used for the degradation of polysaccharide biomass. In silico analysis of the genome sequence of T. cellulolyticus detected seven open reading frames (ORFs) showing homology to xylanases from glycoside hydrolase (GH) family 11. The gene encoding the GH11 xylanase C (TcXylC) with the highest activity was used for overproduction and purification of the recombinant enzyme, permitting solving of the crystal structure to a resolution of 1.98 Å. In the asymmetric unit, two kinds of the crystal structures of the xylanase were identified. The main structure of the protein showed a β-jelly roll structure. We hypothesize that one of the two structures represents the open form and the other shows the close form. The changing of the flexible region between the two structures is presumed to induce and accelerate the enzyme reaction. The specificity of xylanase toward the branched xylan is discussed in the context of this structural data and by comparison with the other published structures of xylanases. PMID:25138599

  8. DECOLOURIZATION OF SELECTED PROCION DYE USING FUNGI, ACREMONIUM CHRYSOGENUM A COMPARISON WITH PHYSICAL ADSORBENTS

    Directory of Open Access Journals (Sweden)

    M.Prasad Naidu

    2015-12-01

    Full Text Available Azo dyes, based on aromatic amines, may contain these amines as impurities introduced during the manufacturing process. Aromatic amines may also be present as a result of thermal or photochemical degradation of azo dyes. The more stable derivatives contain two aryl groups. As a consequence of ?-delocalization, aryl azo compounds have vivid colors, especially reds, oranges, and yellows. Therefore, they are used as dyes, and are commonly known as azo dyes, an example of which is Disperse Orange. Some azo compounds, eg. methyl orange, are used as acid-base indicators due to the different colors of their acid and salt forms. The development of azo dyes was an important step in the development of the chemi azo colorants range in shade from greenish yellow to orange, red, violet and brown. The colours depend largely on the chemical constitution, whereas different shades rather depend on the physical properties. However, the important disadvantage limiting their commercial application is that most of them are red and none are green. The inoculum was prepared by adding 10ml of saline to the culture tube, which contain the Acremoniumchrysogenum. The present study designed to study the degradation of common laboratory dyes using fungi, acremonium chrysogenum. The dye selected was procion red. The selected dye procion red can be toxic in its secondary reactive form so there is a great need of them to be removed from the environment.

  9. Uveitis in Thailand : emphasis on clinical patterns and novel developments in diagnostics using intraocular fluid analysis

    NARCIS (Netherlands)

    Pathanapitoon, K.

    2010-01-01

    In this thesis, we report on the so far unknown causes of uveitis in Thailand and describe their clinical manifestations. We found out that intraocular infections were the second most common cause of blindness and low vision in a tertiary center in northern Thailand. These infections predominantly c

  10. [Intraocular Inflammation: Autoimmune or Infectious?].

    Science.gov (United States)

    Auw-Hädrich, C; Heinzelmann, S; Coupland, S

    2016-07-01

    Presentation of 3 cases of intraocular inflammation: 1. 47-year old female patient with severe necrotising scleritis and uveitis with underlying granulomatous polyangiitis (formerly known as Wegener granulomatosis, in honour of the German pathologist Friedrich Wegener), known for 10 years. 2. 48-year old male patient with longstanding bilateral uveitis and granulomatous polyangiitis for 2 years. In the histopathological examination of the enucleation specimen, a retrolental tumour turned out to be a granuloma. 3. 57-year old male patient in status post renal transplantation with intraocular cellular infiltration suspicious for lymphoma, which surprisingly proved to be Toxoplasma gondii-associated uveitis. The clinical course and characteristic histological signs and therapeutic options are discussed. PMID:27468098

  11. Caracterización fenotípica y molecular de hongos filamentosos oportunistas: scedosporium, acremonium, phialemonium, lecythophora y paecilomyces

    OpenAIRE

    Perdomo Ziems, Haybrig Mercedes

    2011-01-01

    Se estudiaron los géneros Scedosporium, Acremonium, Phialemonium, Lecythophora y Paecilomyces. En Scedosporium se seleccionó la mejor herramienta para la tipificación de S. aurantiacum y S. prolificans. En los otros géneros se estudiaron la identificación morfológica y molecular para establecer el espectro de especies y sus relaciones filogenéticas. Los resultados indican que el sistema basado en la secuenciación multilocus es la mejor metodología para la tipificación de Scedosporium. Se ha ...

  12. Soluble inhibitors generated during hydrothermal pretreatment of oil palm mesocarp fiber suppressed the catalytic activity of Acremonium cellulase.

    Science.gov (United States)

    Zakaria, Mohd Rafein; Hirata, Satoshi; Fujimoto, Shinji; Ibrahim, Izzudin; Hassan, Mohd Ali

    2016-01-01

    Oil palm mesocarp fiber was subjected to hydrothermal pretreatment under isothermal and non-isothermal conditions. The pretreated slurries were separated by filtration, pretreated liquids and solids were characterized. An enzymatic digestibility study was performed for both pretreated slurries and solids to understand the effect of soluble inhibitors generated during the pretreatment process. The highest glucose yield obtained from pretreated slurries was 70.1%, and gradually decreased with higher pretreatment severities. The highest glucose yield obtained in pretreated solids was 100%, after pretreatment at 210°C for 20min. In order to study the inhibitory effects of compounds generated during pretreatment with cellulase, technical grade solutions that mimic the pretreated liquid were prepared and their effect on Acremonium cellulase activity was monitored using Avicel. Xylo-oligomers and tannic acid were identified as powerful inhibitors of Acremonium cellulase, and the lowest hydrolysis rate of Avicel of 0.18g/g-glucose released/L/h was obtained from tannic acid. PMID:26524253

  13. Intraocular lens with accommodation capacity

    OpenAIRE

    Dorronsoro, Carlos; Alejandre, Nicolás; Bekesi, Nandor; Marcos, Susana

    2014-01-01

    Intraocular lens with accommodation capacity comprising a first optical member (1) having a dynamic optical power, to which a second optical member (2) with a fixed optical power is affixed, in such a manner that at least a central part of each of one of one of the curved surfaces (2a, 2b) of the second optical member (2) and of at least one of the surfaces (1a, 1b) of the first optical member (1) are in contact with each other, the second optical member (2) and the first optical member (1) p...

  14. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  15. Cytomegalovirus retinitis mimicking intraocular lymphoma

    Directory of Open Access Journals (Sweden)

    Patrick Gooi

    2008-12-01

    Full Text Available Patrick Gooi1, James Farmer2, Bernard Hurley3, Elliott Brodbaker41Department of Ophthalmology, University of Calgary, Calgary, Alberta, Canada; 2Department of Pathology and Lab Medicine University of Ottawa and The Ottawa Hospital, Ottawa, Ontario, Canada; 3Department of Ophthalmology, University of Ottawa Eye Institute and The Ottawa Hospital, Ottawa, Ontario, Canada; 4Faculty of Medicine, University of Ottawa, Ottawa, Ontario, CanadaAbstract: We present a case of an unusual retinal infiltrate requiring retinal biopsy for definitive diagnosis. A 62-year-old man with treated lymphoma presented with decreased vision in the right eye associated with a white retinal lesion, which extended inferonasally from an edematous disc. Intraocular lymphoma was considered as a diagnosis; thus, the patient was managed with vitrectomy and retinal biopsy. Cytological analysis of the vitreous aspirate could not rule out a lymphoproliferative disorder. The microbial analysis was negative. Histology of the lesion showed extensive necrosis and large cells with prominent nucleoli. To rule out lymphoma, a battery of immunostains was performed and all were negative. However the limited amount of tissue was exhausted in the process. Subsequently, a hematoxylin and eosin (H/E slide was destained, on which a CMV immunostain was performed. This revealed positivity in the nuclei and intranuclear inclusions within the large atypical cells. A diagnosis of CMV retinitis was made. Retinal biopsy may provide a definitive diagnosis and direct patient care toward intravenous gancyclovir in the case of CMV or toward radiation and chemotherapy for intraocular lymphoma. When faced with a limited amount of tissue, destaining regular H/E slides is a possible avenue to performing additional immunohistochemical studies.Keywords: CMV retinitis, retinal biopsy, immunohistochemistry, destaining

  16. Intraocular cilia associated with perforating injury

    Directory of Open Access Journals (Sweden)

    Gopal Lingam

    2000-01-01

    Full Text Available Purpose: To report a case series of penetrating injury complicated by occurrence of intraocular cilia. Methods: Retrospective analysis of charts of 11 eyes of 11 patients with penetrating injury and intraocular cilia, presenting between September 1978 and November 1998. Ten eyes underwent surgery for trauma-related problems such as cataract, vitritis, retinal detachment etc., at which time intraocular cilia were removed. One eye did not have surgery and continues to harbour cilia at the posterior perforation site. Results: Metallic wire was responsible for injury in 6 of 11 eyes with intraocular cilia. Five eyes had significant intraocular inflammation. The cilia were located in the anterior segment in 4 eyes; in the posterior segment in 6 eyes and in both in one eye. At the last follow up, 72.7% had 6/18 or better vision. Poor vision in the rest was due to recurrent retinal detachment (2 eyes and macular scarring (1 eye. Conclusion: Intraocular cilia are more commonly associated with injury by a metallic wire. The presentation and management of an injured eye does not seem to be influenced by the presence of cilia in the eye.

  17. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  18. Biopsy techniques for intraocular tumors.

    Science.gov (United States)

    Rishi, Pukhraj; Dhami, Abhinav; Biswas, Jyotirmay

    2016-06-01

    Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB) to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous), suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies. PMID:27488148

  19. Surface Modification of Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Qi Huang

    2016-01-01

    Full Text Available Objective: This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs. Data Sources: All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect. Study Selection: The articles on the surface modification of IOLs were included, but those on design modification and surface coating were excluded. Results: Technology of surface modification included plasma, ion beam, layer-by-layer self-assembly, ultraviolet radiation, and ozone. The main molecules introduced into IOLs surface were poly (ethylene glycol, polyhedral oligomeric silsesquioxane, 2-methacryloyloxyethyl phosphorylcholine, TiO 2 , heparin, F-heparin, titanium, titanium nitride, vinyl pyrrolidone, and inhibitors of cytokines. The surface modification either resulted in a more hydrophobic lens, a more hydrophilic lens, or a lens with a hydrophilic anterior and hydrophobic posterior surface. Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments. Conclusion: The surface modification is an efficient, convenient, economic and promising method to improve the biocompatibility of IOLs.

  20. Surface Modification of Intraocular Lenses

    Institute of Scientific and Technical Information of China (English)

    Qi Huang; George Pak-Man Cheng; Kin Chiu; Gui-Qin Wang

    2016-01-01

    Objective:This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs).Data Sources:All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect.Study Selection:The articles on the surface modification of IOLs were included,but those on design modification and surface coating were excluded.Results:Technology of surface modification included plasma,ion beam,layer-by-layer self-assembly,ultraviolet radiation,and ozone.The main molecules introduced into IOLs surface were poly (ethylene glycol),polyhedral oligomeric silsesquioxane,2-methacryloyloxyethyl phosphorylcholine,TiO2,heparin,F-heparin,titanium,titanium nitride,vinyl pyrrolidone,and inhibitors of cytokines.The surface modification either resulted in a more hydrophobic lens,a more hydrophilic lens,or a lens with a hydrophilic anterior and hydrophobic posterior surface.Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments.Conclusion:The surface modification is an efficient,convenient,economic and promising method to improve the biocompatibility ofIOLs.

  1. Endophthalmitis due to an intra-ocular linear foreign body in a cat

    Directory of Open Access Journals (Sweden)

    Esmeralda Delgado

    2015-05-01

    Full Text Available Case summary An unusual case of an intraocular linear foreign body that migrated from the oral cavity, causing a severe endophthalmitis, in a cat is described. A 2-year-old female domestic shorthair cat presented with signs of infection from the left eye that had begun 2 weeks previously. Despite having been prescribed oral and topical antibiotics, there was a progressive worsening of the clinical signs. On ophthalmic examination the cat presented with severe endophthalmitis, secondary glaucoma and exposure keratitis of the left eye. Radiography demonstrated the presence of an intraocular linear metallic foreign body compatible with a sewing needle. During enucleation, when the globe was extracted, the sewing needle stayed in the orbit. When the needle was pulled away, a piece of thread was also retrieved, which demonstrated that the linear foreign body had migrated retrogradely from the oral cavity to the orbit through the pterygopalatine fossa. Surgical recovery was uneventful. Relevance and novel information Intraocular foreign bodies may present in a variety of ways, which may hinder their clinical detection. The management and prognosis depend on the composition and location of the foreign body, as well as the possible presence of secondary infection. To the author’s knowledge, this is the first time that a case of severe endophthalmitis following retrograde intraocular migration of a linear foreign body from the oral cavity to the orbit through the pterygopalatine fossa in a cat has been reported.

  2. Late opacification of a hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Al-Bdour Muawyah

    2008-01-01

    Full Text Available Cataract extraction and intraocular lens implantation is considered to be a safe procedure in most cases. However, the new advances in the surgical technique namely phacoemulsification and hence the increased use of foldable intraocular lenses have given rise to new complications including late opacification of intraocular lenses. In this case we report late opacification of a foldable hydrophilic acrylic intraocular lens and the surgical technique for its exchange.

  3. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    Directory of Open Access Journals (Sweden)

    Emre Güler

    2014-03-01

    Full Text Available Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalmol 2014; 44: 156-7

  4. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    OpenAIRE

    Emre Güler; Aylin Tenlik; Tuba Kara Akyüz

    2014-01-01

    Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalm...

  5. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens guide. 886.4300 Section 886.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device...

  6. Closed intraocular microsurgery in ocular trauma.

    Science.gov (United States)

    Kanski, J J

    1978-04-01

    A series of 53 eyes that had suffered severe trauma was treated by closed intraocular microsurgery with vitreous cutters. The cases were divided into three categories: (a) anterior segment reconstruction for traumatic cataracts and post-traumatic pupillary membranes, (b) vitreous haemorrhage with and without retinal detachment, and (c) traumatically dislocated lenses.

  7. Associations with intraocular pressure across Europe

    DEFF Research Database (Denmark)

    Khawaja, Anthony P; Springelkamp, Henriët; Creuzot-Garcher, Catherine;

    2016-01-01

    Raised intraocular pressure (IOP) is the most important risk factor for developing glaucoma, the second commonest cause of blindness globally. Understanding associations with IOP and variations in IOP between countries may teach us about mechanisms underlying glaucoma. We examined cross-sectional...

  8. Characterizing intraocular tumors with photoacoustic imaging

    Science.gov (United States)

    Xu, Guan; Xue, Yafang; Gursel, Zeynep; Slimani, Naziha; Wang, Xueding; Demirci, Hakan

    2016-03-01

    Intraocular tumors are life-threatening conditions. Long-term mortality from uveal melanoma, which accounts for 80% of primary intraocular tumors, could be as high as 25% depending on the size, ciliary body involvement and extraocular extension. The treatments of intraocular tumors include eye-sparing approaches such as radiotherapy and thermotherapy, and the more aggressive enucleation. The accurate diagnosis of intraocular tumors is thereby critical in the management and follow-up of the patients. The diagnosis of intraocular tumors is usually based on clinical examination with acoustic backscattering based ultrasonography. By analyzing the high frequency fluctuations within the ultrasound (US) signals, microarchitecture information inside the tumor can be characterized. However, US cannot interrogate the histochemical components formulating the microarchitecture. One representative example is the inability of US imaging (and other contemporary imaging modalities as well) in differentiating nevoid and melanoma cells as the two types of cells possesses similar acoustic backscattering properties. Combining optical and US imaging, photoacoustic (PA) measurements encode both the microarchitecture and histochemical component information in biological tissue. This study attempts to characterize ocular tumors by analyzing the high frequency signal components in the multispectral PA images. Ex vivo human eye globes with melanoma and retinoblastoma tumors were scanned using less than 6 mJ per square centimeters laser energy with tunable range of 600-1700 nm. A PA-US parallel imaging system with US probes CL15-7 and L22-14 were used to acquire the high frequency PA signals in real time. Preliminary results show that the proposed method can identify uveal melanoma against retinoblastoma tumors.

  9. Management of dislocated intraocular implants.

    Science.gov (United States)

    Chan, C K; Agarwal, A; Agarwal, S; Agarwal, A

    2001-12-01

    Implant dislocation may occur in the absence of appropriate capsular or zonular support (PCIOL) (11,35,53) or following traumatic injury to anterior ocular tissues (ACIOL). (11,19,20) Other factors (e.g., advanced patient age, high myopia, previous vitrectomy, pseudoexfoliation syndrome, and certain connective tissue disorders) also may predispose implant dislocation. (9,52) Although reported for all types of IOLs, implant dislocation is becoming more manageable because of the advancement of surgical techniques. A dislocated ACIOL or PCIOL may be explanted, exchanged, or repositioned. (11,48,71) Repositioning the dislocated PCIOL in the ciliary sulcus with modern vitreoretinal techniques provides an optimal environment for visual recovery. (11,71) Implant repositioning techniques generally may be categorized into the external or the internal approaches. (8,11) The former involves external suturing methods for a primary or secondary implant in the absence of adequate capsular or zonular support (15,16,31,42,56,60,61,64,66,73,76) and the latter is achieved through modern pars plana techniques. 8,11,62,69) Recently, several implant repositioning methods gaining increasing acceptance include the scleral loop fixation, (45) the snare approach, (43) the use of the 25-gauge implant forceps, (13) temporary haptic externalization, (8,11,36,71) and the use of perfluorocarbon liquids. (1,28,40,41,44) The temporary haptic externalization method combines the best features of the external and the internal approaches, avoids complex intraocular maneuvers, and allows precise scleral fixation of the dislocated IOL on a consistent basis. (8,11,71) Endoscopy provides the surgeon with optimal viewing of the anterior retropupillary anatomy that is often difficult to appreciate (e.g., capsular-zonular complex, ciliary sulcus, anterior retina, and vitreous base). (6,11) As a result, precise haptic placement is possible during the repositioning process. (6,11) However, a three

  10. The Visual Effects of Intraocular Colored Filters

    Directory of Open Access Journals (Sweden)

    Billy R. Hammond

    2012-01-01

    Full Text Available Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans.

  11. Intraocular pressure in Japanese diabetic patients

    OpenAIRE

    Matsuoka M; Ogata N.; Matsuyama K; Yoshikawa T.; Takahashi K.

    2012-01-01

    Masato Matsuoka,1 Nahoko Ogata,2 Kayako Matsuyama,1 Tadanobu Yoshikawa,1 Kanji Takahashi31Department of Ophthalmology, Kansai Medical University, Takii Hospital, Osaka, 2Department of Ophthalmology, Nara Medical University, Nara, 3Department of Ophthalmology, Kansai Medical University, Hirakata Hospital, Osaka, JapanBackground: To determine whether the intraocular pressure (IOP) in diabetic patients is significantly different from that in nondiabetic patients.Methods: The medical records of a...

  12. Adherence of Staphylococcus epidermidis to intraocular lenses.

    OpenAIRE

    Griffiths, P G; Elliot, T. S.; McTaggart, L

    1989-01-01

    We have demonstrated, with an in vitro model, that Staphylococcus epidermidis is able to colonise intraocular lenses. Adherent organisms were quantitated by light microscopy, scanning electron microscopy, and viable counting. Bacterial adherence was associated with production of a polysaccharide glycocalyx. Organisms which were attached to the lenses were resistant to apparently bactericidal concentrations of antibiotics, as determined by conventional testing. We speculate on the role of colo...

  13. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    OpenAIRE

    Elena Bonafonte Marquez; Sergio Bonafonte Royo

    2015-01-01

    We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL) implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for i...

  14. Introduction to the development of intraocular lens

    Science.gov (United States)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  15. File list: DNS.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.20.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  16. File list: DNS.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.10.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  17. File list: DNS.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.50.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  18. File list: DNS.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Oth.05.AllAg.Lenses,_Intraocular mm9 DNase-seq Others Lenses, Intraocular http:...//dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/DNS.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  19. Quality of vision through diffractive bifocal intraocular lenses.

    OpenAIRE

    Jay, J L; Chakrabarti, H S; Morrison, J D

    1991-01-01

    Two elderly women have each received a monofocal intraocular lens in one eye and a 3M diffractive bifocal intraocular lens in the other eye. Both eyes were shown to have equivalent retinal/neural function by measuring contrast sensitivity to laser interference fringes which bypassed refractive and other defects of the ocular media. The eyes with a bifocal intraocular lens displayed a much greater depth of focus, though at the expense of diminished contrast sensitivity compared with the normal...

  20. Effect of a tight necktie on intraocular pressure

    OpenAIRE

    Božić Marija; Hentova-Senćanin Paraskeva; Branković Aleksandra; Marjanović Ivan; Jocić Đorđević Jasmina; Senćanin Ivan

    2012-01-01

    Introduction. Any factor causing constriction of the neck may lead to an increase in intraocular pressure. A tight necktie may result in increasing intraocular pressure, which could lead to an erroneous diagnosis and treatment of ocular hypertension or even glaucoma. This study was aimed at evaluating the effect of a tight necktie on intraocular pressure measurement using Goldmann applanation tonometry. Material and Methods. This study included forty eyes of 20 patients with primary ope...

  1. One-pot bioethanol production from cellulose by co-culture of Acremonium cellulolyticus and Saccharomyces cerevisiae

    Directory of Open Access Journals (Sweden)

    Park Enoch Y

    2012-08-01

    Full Text Available Abstract Background While the ethanol production from biomass by consolidated bioprocess (CBP is considered to be the most ideal process, simultaneous saccharification and fermentation (SSF is the most appropriate strategy in practice. In this study, one-pot bioethanol production, including cellulase production, saccharification of cellulose, and ethanol production, was investigated for the conversion of biomass to biofuel by co-culture of two different microorganisms such as a hyper cellulase producer, Acremonium cellulolyticus C-1 and an ethanol producer Saccharomyces cerevisiae. Furthermore, the operational conditions of the one-pot process were evaluated for maximizing ethanol concentration from cellulose in a single reactor. Results Ethanol production from cellulose was carried out in one-pot bioethanol production process. A. cellulolyticus C-1 and S. cerevisiae were co-cultured in a single reactor. Cellulase producing-medium supplemented with 2.5 g/l of yeast extract was used for productions of both cellulase and ethanol. Cellulase production was achieved by A. cellulolyticus C-1 using Solka-Floc (SF as a cellulase-inducing substrate. Subsequently, ethanol was produced with addition of both 10%(v/v of S. cerevisiae inoculum and SF at the culture time of 60 h. Dissolved oxygen levels were adjusted at higher than 20% during cellulase producing phase and at lower than 10% during ethanol producing phase. Cellulase activity remained 8–12 FPU/ml throughout the one-pot process. When 50–300 g SF/l was used in 500 ml Erlenmeyer flask scale, the ethanol concentration and yield based on initial SF were as 8.7–46.3 g/l and 0.15–0.18 (g ethanol/g SF, respectively. In 3-l fermentor with 50–300 g SF/l, the ethanol concentration and yield were 9.5–35.1 g/l with their yields of 0.12–0.19 (g/g respectively, demonstrating that the one-pot bioethanol production is a reproducible process in a scale-up bioconversion of cellulose to ethanol

  2. Infection

    Science.gov (United States)

    ... Potential Hazards Exposure of employees to community and nosocomial infections, e.g., Methicillin-resistant Staphylococcus aureus (MRSA) . Nosocomial infections are infections that occur from exposure to infectious ...

  3. Intraocular lymphoma after cardiac transplantation: Magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yi Kyung; Kim, Hyung Jin; Woo, Kyung In; Kim, Yoon Duck [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2013-01-15

    We report a case of intraocular lymphoma in a 65-year-old man, 15 months after cardiac transplantation. On Magnetic Resonance (MR) images, the iris and the anterior chamber of the right eye were found to be involved with an enhancing soft-tissue lesion. To our knowledge, this is the first case of post-transplantation intraocular lymphoma evaluated with MR imaging.

  4. Out-of-the-bag intraocular lens dislocation: outcomes of posterior chamber intraocular lens exchange, risk factors, and prevention

    Institute of Scientific and Technical Information of China (English)

    ZHENG Dan-ying; CHEN Li-na; SUN Yi; SHAO Ying-feng; LIANG Jing-li; LIU Yi-zhi

    2010-01-01

    Background Dislocation of posterior chamber intraocular lens is one of the most common complications of intraocular lens implantation. Lens exchange is an effective solution to this unsatisfactory status. This study was conducted to analyze the possible predisposing factors for out-of-the-bag posterior chamber intraocular lens dislocation and to study the outcomes of lens exchange surgery.Methods Thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation who underwent posterior chamber intraocular lens exchange in Zhongshan Ophthalmic Center of Sun Yat-sen University (Guangdong,China) from January 2003 to October 2009 were included. A 6-month follow-up was completed. The causes for out-of-the-bag intraocular lens dislocation and visual outcomes of posterior chamber intraocular lens exchange were analyzed. The out-of-the-bag intraocular lens dislocation was diagnosed on the basis of the findings from slit-lamp microscope and B-ultrasound. The dislocated intraocular lens was explanted. Reimplantation of a new posterior chamber intraocular lens was performed in each case using standardized surgical procedures.Results In this study, a total of thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation underwent posterior chamber intraocular lens exchange surgery. Causes for out-of-the-bag intraocular lens dislocation included posterior capsule rupture during the initial cataract extraction procedure (23 eyes, 63.8%), trauma (5 eyes,13.9%), neodymium-doped yttrium aluminium garnet (Nd:YAG) laser-induced dislocation (2 eyes, 5.6%), the status after vitrectomy (2 eyes, 5.6%) and unidentifiable etiology (4 eyes, 11.1%). Symptoms of these patients mainly included decrease in visual acuity (17 cases, 47.2%), blurred vision (16 cases, 44.4%), glare (1 case, 2.8%), diplopia (1 case,2.8%), and halo (1 case, 2.8%). Intraocular lens dislocation into the posterior vitreous cavity (29 eyes, 80.5%), anterior chamber (1

  5. How to measure intraocular pressure: applanation tonometry

    Directory of Open Access Journals (Sweden)

    Nick Astbury

    2012-01-01

    Full Text Available Unless there is a contraindication (e.g. trauma or corneal ulcer, all adults attending an eye unit should have their intraocular pressure (IOP measured. Many people with glaucoma have no symptoms and do not know they have the condition. All children who have had cataract surgery should also have their IOP measured at every follow-up visit, if possible. Finding glaucoma early allows treatment to be given which will preserve sight. Although elevated IOP is not the only sign of glaucoma, measuring it is simple and quick to do. Applanation tonometry, using a Goldmann tonometer at a slit lamp, is the preferred method (the ‘gold standard’.

  6. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    Directory of Open Access Journals (Sweden)

    Elena Bonafonte Marquez

    2015-01-01

    Full Text Available We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for it could be the only sign of secondary glaucoma.

  7. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  8. Severe South American ocular toxoplasmosis is associated with decreased Ifn-γ/Il-17a and increased Il-6/Il-13 intraocular levels.

    Directory of Open Access Journals (Sweden)

    Alejandra de-la-Torre

    2013-11-01

    Full Text Available In a cross sectional study, 19 French and 23 Colombian cases of confirmed active ocular toxoplasmosis (OT were evaluated. The objective was to compare clinical, parasitological and immunological responses and relate them to the infecting strains. A complete ocular examination was performed in each patient. The infecting strain was characterized by genotyping when intraocular Toxoplasma DNA was detectable, as well as by peptide-specific serotyping for each patient. To characterize the immune response, we assessed Toxoplasma protein recognition patterns by intraocular antibodies and the intraocular profile of cytokines, chemokines and growth factors. Significant differences were found for size of active lesions, unilateral macular involvement, unilateral visual impairment, vitreous inflammation, synechiae, and vasculitis, with higher values observed throughout for Colombian patients. Multilocus PCR-DNA sequence genotyping was only successful in three Colombian patients revealing one type I and two atypical strains. The Colombian OT patients possessed heterogeneous atypical serotypes whereas the French were uniformly reactive to type II strain peptides. The protein patterns recognized by intraocular antibodies and the cytokine patterns were strikingly different between the two populations. Intraocular IFN-γ and IL-17 expression was lower, while higher levels of IL-13 and IL-6 were detected in aqueous humor of Colombian patients. Our results are consistent with the hypothesis that South American strains may cause more severe OT due to an inhibition of the protective effect of IFN-γ.

  9. Effect of a tight necktie on intraocular pressure

    Directory of Open Access Journals (Sweden)

    Božić Marija

    2012-01-01

    Full Text Available Introduction. Any factor causing constriction of the neck may lead to an increase in intraocular pressure. A tight necktie may result in increasing intraocular pressure, which could lead to an erroneous diagnosis and treatment of ocular hypertension or even glaucoma. This study was aimed at evaluating the effect of a tight necktie on intraocular pressure measurement using Goldmann applanation tonometry. Material and Methods. This study included forty eyes of 20 patients with primary open angle glaucoma and 20 healthy controls (all male. Intraocular pressure was measured without a necktie, 3 minutes after placing a tight necktie and 3 minutes after loosening it. Student’s t-test was used to analyze the data between two groups. The intraocular pressure measurements were subjected to paired t - test. The value p < 0.05 was considered statistically significant. A possible correlation between the age of subjects and intraocular pressure values was analyzed using linear regression (Pearson′. Results. A statistically significant difference was found in intraocular pressure readings in all three measurements between two tested groups (p<0.05. When analyzed within groups, statistical significance in intraocular pressure readings was found after loosening the necktie (<0.05. No correlation between the age of subjects and increased intraocular pressure was found in either tested group of subjects after the necktie had been tightened (r2=0.006, p=0.70 for primary open angle patients, r2=0.07, p=0.22 for healthy controls. Conclusion. Wearing a tight necktie for a limited period of time during the day could be considered as a possible risk factor for glaucoma development.

  10. Intraocular Implants for the Treatment of Autoimmune Uveitis

    Directory of Open Access Journals (Sweden)

    Darren J. Lee

    2015-07-01

    Full Text Available Uveitis is the third leading cause of blindness in developed countries. Currently, the most widely used treatment of non-infectious uveitis is corticosteroids. Posterior uveitis and macular edema can be treated with intraocular injection of corticosteroids, however, this is problematic in chronic cases because of the need for repeat injections. Another option is systemic immunosuppressive therapies that have their own undesirable side effects. These systemic therapies result in a widespread suppression of the entire immune system, leaving the patient susceptible to infection. Therefore, an effective localized treatment option is preferred. With the recent advances in bioengineering, biodegradable polymers that allow for a slow sustained-release of a medication. These advances have culminated in drug delivery implants that are food and drug administration (FDA approved for the treatment of non-infectious uveitis. In this review, we discuss the types of ocular implants available and some of the polymers used, implants used for the treatment of non-infectious uveitis, and bioengineered alternatives that are on the horizon.

  11. Lente intra-ocular multifocal difrativa apodizada: resultados Diffractive apodized multifocal intraocular lens: results

    Directory of Open Access Journals (Sweden)

    Virgilio Centurion

    2007-12-01

    Full Text Available OBJETIVO: Mostrar os resultados visuais e refracionais com lente intra-ocular multifocal difrativa apodizada. MÉTODOS: Estudo de 100 olhos de 50 pacientes com catarata, submetidos à facoemulsificação com implante bilateral de lente intra-ocular (LIO multifocal difrativa apodizada. Foi avaliada a acuidade visual binocular sem e com correção para longe e perto, a previsibilidade refracional e a freqüência de uso de óculos. RESULTADOS: A acuidade visual sem correção para longe foi de e " 20/30 em 97,56% dos olhos operados e e" J2 em 100%, sendo que 82% dos pacientes nunca usam óculos e 16% usam de forma esporádica. CONCLUSÃO: A LIO multifocal difrativa apodizada mostrou ser uma opção previsível, reproduzível e segura na correção dos vícios de refração para longe e perto durante a cirurgia da catarata, permitindo elevado índice de independência ao uso de óculos.OBJECTIVE: To show visual and refraction results using multifocal diffractive apodized intraocular lens. METHODS: The study of 100 eyes of 50 patients with cataract, submitted to phacoemulsification with bilateral implant of multifocal diffractive apodized intraocular lens (IOL. Binocular visual acuity was evaluated with and without correction for near and distance, and refraction previsibility and frequency of wearing glasses. RESULTS: Visual acuity without correction for distance was e" 20/30 in 97.56% of eyes operated on and e" J2 in 100%, of these 82% of patients never wear glasses and 16% wear glasses sporadically. CONCLUSION: Multifocal diffractive apodized IOL proved to be a foreseeable option, reproducible and safe in the correction of refraction errors for distance and near during cataract surgery, enabling a high rate of independence from the use of glasses.

  12. MicroRNA profiling in intraocular medulloepitheliomas.

    Directory of Open Access Journals (Sweden)

    Deepak P Edward

    Full Text Available To study the differential expression of microRNA (miRNA profiles between intraocular medulloepithelioma (ME and normal control tissue (CT.Total RNA was extracted from formalin fixed paraffin embedded (FFPE intraocular ME (n=7 and from age matched ciliary body controls (n=8. The clinical history and phenotype was recorded. MiRNA profiles were determined using the Affymetrix GeneChip miRNA Arrays analyzed using expression console 1.3 software. Validation of significantly dysregulated miRNA was confirmed by quantitative real-time PCR. The web-based DNA Intelligent Analysis (DIANA-miRPath v2.0 was used to perform enrichment analysis of differentially expressed (DE miRNA gene targets in Kyoto Encyclopedia of Genes and Genomes (KEGG pathway.The pathologic evaluation revealed one benign (benign non-teratoid, n=1 and six malignant tumors (malignant teratoid, n=2; malignant non-teratoid, n = 4. A total of 88 miRNAs were upregulated and 43 miRNAs were downregulated significantly (P<0.05 in the tumor specimens. Many of these significantly dysregulated miRNAs were known to play various roles in carcinogenesis and tumor behavior. RT-PCR validated three significantly upregulated miRNAs and three significantly downregulated miRNAs namely miR-217, miR-216a, miR-216b, miR-146a, miR-509-3p and miR-211. Many DE miRNAs that were significant in ME tumors showed dysregulation in retinoblastoma, glioblastoma, and precursor, normal and reactive human cartilage. Enriched pathway analysis suggested a significant association of upregulated miRNAs with 15 pathways involved in prion disease and several types of cancer. The pathways involving significantly downregulated miRNAs included the toll-like receptor (TLR (p<4.36E-16 and Nuclear Factor kappa B (NF-κB signaling pathways (p<9.00E-06.We report significantly dysregulated miRNAs in intraocular ME tumors, which exhibited abnormal profiles in other cancers as well such as retinoblastoma and glioblastoma. Pathway analysis

  13. Intraocular lens employed for cataract surgery

    International Nuclear Information System (INIS)

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  14. Mechanical properties of intra-ocular lenses

    Science.gov (United States)

    Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie

    2008-02-01

    Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements

  15. Primary orbital neuroblastoma with intraocular extension

    Directory of Open Access Journals (Sweden)

    Muthukrishnan Vallinayagam

    2015-01-01

    Full Text Available Neuroblastoma is an undifferentiated malignancy of primitive neuroblasts. Neuroblastoma is among the most common solid tumors of childhood. Orbital neuroblastoma is typically a metastatic tumor. In this case report, we describe a 2-year-old child with a rapidly progressing orbital tumor. Computed tomography revealed an orbital mass lesion with extraocular and intraocular components. An incisional biopsy was done, and a histopathological examination showed features suggestive of neuroblastoma. Systemic workup including ultrasonography of the abdomen, chest roentgenogram, whole body computed tomography, and bone scintigraphy showed no evidence of systemic involvement. The diagnosis of primary orbital neuroblastoma was made, and the child was subjected to chemotherapy followed by rapid melting of the tumor. Neuroblastoma should be considered in the differential diagnosis of childhood orbital tumors.

  16. Intraocular lens employed for cataract surgery

    Science.gov (United States)

    Roszkowska, A. M.; Torrisi, L.

    2014-04-01

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  17. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  18. Intraocular pressure in Japanese diabetic patients

    Directory of Open Access Journals (Sweden)

    Matsuoka M

    2012-07-01

    Full Text Available Masato Matsuoka,1 Nahoko Ogata,2 Kayako Matsuyama,1 Tadanobu Yoshikawa,1 Kanji Takahashi31Department of Ophthalmology, Kansai Medical University, Takii Hospital, Osaka, 2Department of Ophthalmology, Nara Medical University, Nara, 3Department of Ophthalmology, Kansai Medical University, Hirakata Hospital, Osaka, JapanBackground: To determine whether the intraocular pressure (IOP in diabetic patients is significantly different from that in nondiabetic patients.Methods: The medical records of all patients who were initially examined in the Department of Ophthalmology, Kansai Medical University, Takii Hospital were reviewed. At the initial examination, patients had a detailed interview and underwent a comprehensive ophthalmic examinations. All patients were over 20 years of age and did not have glaucoma.Results: A total of 703 patients were evaluated. The mean (±standard error IOP of the diabetic patients was 15.5 ± 0.2 mmHg (n = 206, and was significantly higher than the 14.0 ± 0.1 mmHg (n = 497 in the nondiabetic patients (P < 0.0001. The IOP was negatively correlated with age (r = –0.202; P = 0.024 in the diabetic patients and was weakly but significantly correlated with the glycosylated hemoglobin (HbA1c level (r = 0.240; P = 0.015 in the group with diabetic retinopathy.Conclusion: The significantly higher IOP in diabetic patients and positive correlation of IOP with HbA1c levels in patients with diabetic retinopathy indicate that IOP in diabetic patients is higher, especially in those with poor control of diabetes.Keywords: diabetes mellitus, diabetic retinopathy, intraocular pressure, open-angle glaucoma

  19. Computational modeling of intraocular gas dynamics

    Science.gov (United States)

    Noohi, P.; Abdekhodaie, M. J.; Cheng, Y. L.

    2015-12-01

    The purpose of this study was to develop a computational model to simulate the dynamics of intraocular gas behavior in pneumatic retinopexy (PR) procedure. The presented model predicted intraocular gas volume at any time and determined the tolerance angle within which a patient can maneuver and still gas completely covers the tear(s). Computational fluid dynamics calculations were conducted to describe PR procedure. The geometrical model was constructed based on the rabbit and human eye dimensions. SF6 in the form of pure and diluted with air was considered as the injected gas. The presented results indicated that the composition of the injected gas affected the gas absorption rate and gas volume. After injection of pure SF6, the bubble expanded to 2.3 times of its initial volume during the first 23 h, but when diluted SF6 was used, no significant expansion was observed. Also, head positioning for the treatment of retinal tear influenced the rate of gas absorption. Moreover, the determined tolerance angle depended on the bubble and tear size. More bubble expansion and smaller retinal tear caused greater tolerance angle. For example, after 23 h, for the tear size of 2 mm the tolerance angle of using pure SF6 is 1.4 times more than that of using diluted SF6 with 80% air. Composition of the injected gas and conditions of the tear in PR may dramatically affect the gas absorption rate and gas volume. Quantifying these effects helps to predict the tolerance angle and improve treatment efficiency.

  20. Intraocular infections in the neonatal intensive care unit

    OpenAIRE

    Sisk RA; Berrocal AM; Aziz HA; Flynn HW Jr; Murray TG; Dubovy SR; Hess D; Johnson RA; Hartley K; Diaz-Barbosa M

    2012-01-01

    Hassan A Aziz1, Audina M Berrocal1,2, Robert A Sisk1, Kristin Hartley1, Magaly Diaz-Barbosa2, Rose A Johnson2, Ditte Hess1, Sander R Dubovy1, Timothy G Murray1, Harry W Flynn Jr11Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, 2Jackson Memorial Hospital, Miami, FL, USABackground: The purpose of this study was to report on the incidence and treatment outcomes of endogenous endophthalmitis among newborns in the neonatal intensive care uni...

  1. Application of Foldable Intraocular Lens in Multiple Types of Cataract

    Institute of Scientific and Technical Information of China (English)

    Songtao Yuan; Qinghuai Liu; Qing Jiang; Nanrong Yuan

    2002-01-01

    Objective: To evaluate the clinical results of implantation of foldable intraocular lens inmultiple types of cataract.Methods: This retrospective study comprised 162 eyes of 148 patients undergoingphacoemulsification and implantation of foldable intraocular lens, some of whom under-went combined pars plana vitrectomy or trabeculectomy or silicone oil removal. Theperiod of follow-up was from 3 months to 17 months.Results: There is slight reaction postoperatively in all cases. The postoperative uncorrectedvisual acuites was from 0. 05 to 1.2, patient with 0.6 or above acuity were 70.98%. Aneodymium: YAG capsulotomy was required in 5 eyes. Posterior capsule ruptured in 1eyes, and a PMMA intraocular lens was implanted in ciliary sulcus. In one eye, a lenswas removed because of recurrence of retina detachment.Conclusions: The application of foldable intraocular lens in multiple types of cataract issafe, and there is a slight postoperative reaction. less complications , and fast visualacuity recovery.

  2. Patient acceptability of the Tecnis® multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Sood P

    2011-03-01

    Full Text Available Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis® multifocal intraocular lens.Keywords: Tecnis®, intraocular lens, multifocal, presbyopia 

  3. Metabolic Syndrome as a Risk Factor for Elevated Intraocular Pressure

    OpenAIRE

    Sahinoglu-Keskek, Nedime; Keskek, Sakir Ozgur; Cevher, Selim; Kirim, Sinan; Kayiklik, Asim; Ortoglu, Gulay; Saler, Tayyibe

    2014-01-01

    Objective: The aim of this study was to investigate the association between intraocular pressure and metabolic syndrome by comparing central corneal thicknesses. Methods: One hundred sixty-two subjects were enrolled in this cross-sectional study, with 89 subjects in a metabolic syndrome group and 73 subjects in a control group. Ophthalmological examinations, including intraocular pressure and central corneal thickness measurements, were performed on each subject. Serum fasting glucose, trigly...

  4. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

    OpenAIRE

    Ladan Espandar; Shameema Sikder; Majid Moshirfar

    2011-01-01

    Ladan Espandar1, Shameema Sikder2, Majid Moshirfar31Department of Ophthalmology, Tulane University, New Orleans, LA, USA; 2Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USAAbstract: Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD™ lens is an aspheric, hydrophilic acrylic intraocular le...

  5. Patient acceptability of the Tecnis® multifocal intraocular lens

    OpenAIRE

    Woodward, Maria; Sood,Priyanka

    2011-01-01

    Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL) designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anter...

  6. Relation between intraocular pressure and size of transverse sinuses.

    Science.gov (United States)

    Kantarci, Mecit; Dane, Senol; Gumustekin, Kenan; Onbas, Omer; Alper, Fatih; Okur, Adnan; Aslankurt, Murat; Yazici, Ahmet Taylan

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean+/-SD; 19.72+/-0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. PMID:15647949

  7. Relation between intraocular pressure and size of transverse sinuses

    Energy Technology Data Exchange (ETDEWEB)

    Kantarci, Mecit; Onbas, Omer; Alper, Fatih; Okur, Adnan [Atatuerk University, Department of Radiology, Medical Faculty, Erzurum (Turkey); Dane, Senol; Gumustekin, Kenan [Atatuerk University, Department of Physiology, Medical Faculty, Erzurum (Turkey); Aslankurt, Murat [Atatuerk University, Department of Ophtalmatology, Medical Faculty, Erzurum (Turkey); Yazici, Ahmet Taylan [Beyoglu Goez Egitim ve Arastirma Hastanesi, Istanbul (Turkey)

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean{+-}SD; 19.72{+-}0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. (orig.)

  8. A study of brachytherapy for intraocular tumor

    International Nuclear Information System (INIS)

    Our purpose of this study is to perform brachytherapy for intraocular tumor. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere. Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm. Maximum error is -11.3% and 0.8 mm, respectively. 7 figs, 2 tabs, 28 refs. (Author)

  9. Surgical management of intraocular lens dislocations

    Directory of Open Access Journals (Sweden)

    Adem Gul

    2015-10-01

    Full Text Available ABSTRACTPurpose:To report and compare the surgical, visual, and anatomical outcomes following treatment of dislocated intraocular lenses (IOLs.Methods:The medical records of 28 eyes of 28 patients were evaluated. Age, gender, pre-and postoperative best-corrected visual acuity (BCVA, surgical methods, and complications were recorded.Results:Pre-and postoperative BCVA ranged from counting fingers to 20/32 and from counting fingers to 20/25, respectively. Late-onset dislocations were the most frequently observed complication. The most frequent surgical method was IOL repositioning in 15 of 28 patients, followed by IOL exchange in 11 patients, and IOL removal in 2 patients. Only 1 patient required surgical re-intervention with IOL capture.Conclusions:Visual acuity improved following the use of either IOL repositioning or IOL exchange. No superiority of one method over the other was observed. In the present retrospective case series, management of dislocated IOLs with repositioning or exchange of the primary implant conferred comparable surgical and visual outcomes.

  10. Intraocular complications of IFN-a and ribavirin therapy in patients with chronic viral hepatitis C

    Institute of Scientific and Technical Information of China (English)

    Damien Sene; Valerie Touitou; Bahram Bodaghi; David Saadoun; Gabriel Perlemuter; Nathalie Cassoux; Jean-Charles Piette; Phuc Le Hoang; Patrice Cacoub

    2007-01-01

    We report a panel of severe inflammatory and vascular intraocular disorders occurring during interferon-alpha (IFN-a) treatment in eight hepatitis C virus (HCV)-infected patients. These events include three cases of Vogt-Koyanagi-Harada like (VKH) disease (an association of panuveitis, retinal detachment, ear and meningeal detachment and skin and hair changes), two cases of central retinal vein occlusion, one case of central retinal artery occlusion, one case of severe hypertensive retinopathy and one case of bilateral ischemic optic neuropathy with severe visual impairment. Rare as they are, such severe ophthalmological complications require a close follow-up of HCV-infected patients under IFN-a treatment with ophthalmological monitoring if any ocular manifestation occurs.

  11. [Intraocular Pressure Sensor Based on a Contact Lens].

    Science.gov (United States)

    Guo, Xuhong; Pet, Weihua; Yao, Zhaolin; Chen, Yuanfang; Hu, Xiaohui; Chen, Hongda; Zhu, Jingyuan; Wu, Huijuan

    2016-02-01

    Intraocular pressure detection has a great significance for understanding the status of eye health, prevention and treatment of diseases such as glaucoma. Traditional intraocular pressure detection needs to be held in the hospital. It is not only time-consuming to doctors and patients, but also difficult to achieve 24 hour-continuous detection. Microminiaturization of the intraocular pressure sensor and wearing it as a contact lens, which is convenient, comfortable and noninvasive, can solve this problem because the soft contact lens with an embedded micro fabricated strain gauge allows the measurement of changes in corneal curvature to correlate to variations of intraocular pressure. We fabricated a strain gauge using micro-electron mechanical systems, and integrated with the contact lens made of polydimethylsiloxane (PDMS) using injection molding. The experimental results showed that the sensitivity was 100. 7 µV/µm. When attached to the corneal surface, the average sensitivity of sensor response of intraocular pressure can be 125.8 µV/mm Hg under the ideal condition. PMID:27382734

  12. Effects of 2-alkynyladenosine derivatives on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Ohnuma, Shin-ya; Uemoto, Kazuhiro; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Endo, Kazuki; Hosokawa, Tomokazu; Nakahata, Norimichi

    2004-02-23

    We evaluated the activities of 2-alkynyladenosine derivatives, relatively selective adenosine A2 receptor agonists, in the intraocular pressure regulation in rabbits. An adenosine A2 receptor agonist 2-[p-(2-carboxyethyl)phenylethylamino]-5'-N-ethylcarboxamidoadenosine (CGS-21680) decreased intraocular pressure, while another A2 receptor agonist 2-(phenylamino)adenosine transiently increased it. The first group of 2-alkynyladenosine derivatives (1-hexyn-1-yl derivatives) caused a transient increase followed by decrease in intraocular pressure, while the second group (1-octyn-1-yl and 6-cyano-1-hexyn-1-yl derivatives) only decreased it. The second group is also effective in the ocular hypertensive models induced by water-loading and alpha-chymotrypsin. The outflow facility was increased by a 1-octyn-1-yl derivative. Both increase and decrease in intraocular pressure induced by 2-alkynyladenosine derivatives were inhibited by an adenosine A2 receptor antagonist 3,7-dimethyl-1-propargylxanthine, but not by an adenosine A1 receptor antagonist 8-cyclopentyl-1,3-dipropyl xanthine. These findings suggest that 2-alkynyladenosine derivatives may affect intraocular pressure via adenosine A2 receptor, and 2-alkynyladenosine derivative-induced ocular hypotension is due to the increase of outflow facility.

  13. Effects of 2-alkynyladenosine derivatives on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Ohnuma, Shin-ya; Uemoto, Kazuhiro; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Endo, Kazuki; Hosokawa, Tomokazu; Nakahata, Norimichi

    2004-02-23

    We evaluated the activities of 2-alkynyladenosine derivatives, relatively selective adenosine A2 receptor agonists, in the intraocular pressure regulation in rabbits. An adenosine A2 receptor agonist 2-[p-(2-carboxyethyl)phenylethylamino]-5'-N-ethylcarboxamidoadenosine (CGS-21680) decreased intraocular pressure, while another A2 receptor agonist 2-(phenylamino)adenosine transiently increased it. The first group of 2-alkynyladenosine derivatives (1-hexyn-1-yl derivatives) caused a transient increase followed by decrease in intraocular pressure, while the second group (1-octyn-1-yl and 6-cyano-1-hexyn-1-yl derivatives) only decreased it. The second group is also effective in the ocular hypertensive models induced by water-loading and alpha-chymotrypsin. The outflow facility was increased by a 1-octyn-1-yl derivative. Both increase and decrease in intraocular pressure induced by 2-alkynyladenosine derivatives were inhibited by an adenosine A2 receptor antagonist 3,7-dimethyl-1-propargylxanthine, but not by an adenosine A1 receptor antagonist 8-cyclopentyl-1,3-dipropyl xanthine. These findings suggest that 2-alkynyladenosine derivatives may affect intraocular pressure via adenosine A2 receptor, and 2-alkynyladenosine derivative-induced ocular hypotension is due to the increase of outflow facility. PMID:14985053

  14. [Intraocular Pressure Sensor Based on a Contact Lens].

    Science.gov (United States)

    Guo, Xuhong; Pet, Weihua; Yao, Zhaolin; Chen, Yuanfang; Hu, Xiaohui; Chen, Hongda; Zhu, Jingyuan; Wu, Huijuan

    2016-02-01

    Intraocular pressure detection has a great significance for understanding the status of eye health, prevention and treatment of diseases such as glaucoma. Traditional intraocular pressure detection needs to be held in the hospital. It is not only time-consuming to doctors and patients, but also difficult to achieve 24 hour-continuous detection. Microminiaturization of the intraocular pressure sensor and wearing it as a contact lens, which is convenient, comfortable and noninvasive, can solve this problem because the soft contact lens with an embedded micro fabricated strain gauge allows the measurement of changes in corneal curvature to correlate to variations of intraocular pressure. We fabricated a strain gauge using micro-electron mechanical systems, and integrated with the contact lens made of polydimethylsiloxane (PDMS) using injection molding. The experimental results showed that the sensitivity was 100. 7 µV/µm. When attached to the corneal surface, the average sensitivity of sensor response of intraocular pressure can be 125.8 µV/mm Hg under the ideal condition.

  15. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  16. File list: Oth.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.50.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  17. File list: NoD.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.05.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  18. File list: Pol.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.20.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  19. File list: Pol.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.05.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  20. File list: InP.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.20.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  1. File list: His.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.10.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957695,SRX957683 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  2. File list: NoD.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.10.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  3. File list: InP.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.05.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  4. File list: Unc.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.50.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  5. File list: His.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.20.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957695,SRX957683 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  6. File list: Pol.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.50.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  7. File list: His.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Oth.50.AllAg.Lenses,_Intraocular mm9 Histone Others Lenses, Intraocular SRX9576...85,SRX957687,SRX957683,SRX957695 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/His.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  8. File list: Oth.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.05.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  9. File list: NoD.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.20.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  10. File list: Unc.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.20.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  11. File list: Oth.Oth.20.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.20.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.20.AllAg.Lenses,_Intraocular.bed ...

  12. File list: NoD.Oth.50.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Oth.50.AllAg.Lenses,_Intraocular mm9 No description Others Lenses, Intraocular ...http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/NoD.Oth.50.AllAg.Lenses,_Intraocular.bed ...

  13. File list: Unc.Oth.05.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Oth.05.AllAg.Lenses,_Intraocular mm9 Unclassified Others Lenses, Intraocular SR...X1127448 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.Oth.05.AllAg.Lenses,_Intraocular.bed ...

  14. File list: Pol.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Oth.10.AllAg.Lenses,_Intraocular mm9 RNA polymerase Others Lenses, Intraocular ...SRX957689 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  15. File list: Oth.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Oth.10.AllAg.Lenses,_Intraocular mm9 TFs and others Others Lenses, Intraocular ...SRX957680 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Oth.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  16. File list: InP.Oth.10.AllAg.Lenses,_Intraocular [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Oth.10.AllAg.Lenses,_Intraocular mm9 Input control Others Lenses, Intraocular S...RX957681,SRX957691,SRX957693 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Oth.10.AllAg.Lenses,_Intraocular.bed ...

  17. Penetrating Scleral Injury with Intraocular Foreign Body. A Case Report

    Directory of Open Access Journals (Sweden)

    Anay Martínez Díaz

    2014-04-01

    Full Text Available Ocular trauma is a health problem in the world today and a common cause of visual impairment leading to severe sequelae and psychological disorders. The case of a 46-year-old male patient who attended the Ophthalmology emergency services of the Dr. Gustavo Aldereguía Lima University General Hospital of Cienfuegos, recounting that while hammering iron on iron he felt that something entered his right eye, is presented. He suffered from pain, tearing, red eye and blurred vision. A penetrating scleral injury with an intraocular foreign body was diagnosed. Its study was conducted through biomicroscopy, orbital x-ray and ocular ultrasound. Surgical treatment by extracapsular lens extraction with intraocular lens implantation was performed using Blumenthal technique and pars plana approach for removal of the intraocular foreign body.

  18. Epithelial Downgrowth after Intraocular Surgery Treated with Intracameral 5-Fluorouracil

    Directory of Open Access Journals (Sweden)

    Nina Ni

    2015-01-01

    Full Text Available Purpose. To present the clinical and histopathologic correlation of two cases of epithelial downgrowth (EDG after prior intraocular surgery. Methods. Observational case reports. Results. We present two cases of EDG occurring after intraocular surgery. In both cases, after two anterior chamber injections of 5-fluorouracil (5FU, the area of EDG initially regressed. In Case 1, a limited area of EDG eventually recurred, and penetrating keratoplasty with cryotherapy was curative. In Case 2, subsequent corneal edema required Descemet-stripping automated endothelial keratoplasty, and the patient remained clinically free of EDG without further treatment. Conclusion. Intracameral 5FU may have a role in the treatment of EDG after intraocular surgery, though its precise utilization and impact remain to be defined.

  19. Recent decreasing frequency of enucleation for intraocular retinoblastoma in Upper Egypt

    International Nuclear Information System (INIS)

    and required EBRT, enucleation, or both (5 eyes in group IV and 9 eyes in group V). Toxicities from chemotherapy were mild and included cytopenias (84%), fever and neutropenia (32%), infection (11%), and gastrointestinal symptoms, dehydration, and dehydration, and vincristine neurotoxicity (39%). No patients developed a second malignancy, metastatic disease or ototoxicity. The author concludes that in appropriately selected patients with RE groups I, II, and III intraocular retinoblastoma, chemoreduction and local ophthalmic therapy are effective and carry little morbidity. However, other treatment options need to be developed for group IV and group V patients. (author)

  20. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Background Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. Methods This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. Results The mean follow-up was 23 months (range: 6–48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. Conclusion The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context

  1. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-08-01

    Full Text Available Mun Yueh Faria,1–3 Nuno Pinto Ferreira,1–3 Joana Medeiros Pinto,1–3 David Cordeiro Sousa,1–3 Ines Leal,1–3 Eliana Neto,1–3 Carlos Marques-Neves1–3 1Centro de Estudos da Visão, Universidade de Lisboa, 2Department of Ophthalmology, Hospital de Santa Maria, 3Faculty of Medicine, University of Lisbon, Lisbon, Portugal Background: Nowadays, dislocated intraocular lenses (IOLs and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL.Methods: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth.Results: The mean follow-up was 23 months (range: 6–48 months. The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1 retinal detachment was found in one patient, 2 corneal edema was found in three patients, 3 high intraocular pressure was observed in

  2. Polyvinylidene Flouride Polymer Applied in an Intraocular Pressure Sensor

    Science.gov (United States)

    González Morán, Carlos Omar; González Ballesteros, Rubén; Rodríguez Guzmán, Maria Dolores Alicia; Suaste Gómez, Ernesto

    2005-06-01

    An indentation intraocular pressure sensor (IIOPS) was designed and manufactured. It is based on piezoelectric polyvinylidene fluoride (PVDF) films. This sensor will help in the detection and diagnosis of intraocular pressure (IOP) in eye diseases like glaucoma. The pressure in the normal aqueous and vitreous phases is, on average, 15.5 mmHg and up of 21 mmHg when glaucoma exists. The proposed IIOPS offers a measurement range from 10-29 mmHg with a resolution of 1 mmHg and an accuracy of ± 0.025.

  3. Comparison of shape recovery ratios in various intraocular lens haptics.

    Science.gov (United States)

    Kimura, W; Kimura, T; Sawada, T; Kikuchi, T; Toda, H; Yamada, Y; Nagai, H

    1992-11-01

    Since understanding the mechanical properties of intraocular lens (IOL) haptic materials can minimize decentration after surgery, we have examined shape recovery ratios of various intraocular lens haptics (polypropylene [PP], polyvinylidene fluoride [PVDF], extruded poly(methyl methacrylate) [PMMA]) currently on the market under conditions that approximate clinical use. The results using various Ascon lens-holding forceps and compression tests, during which the lenses were held in a cylindrical holder for seven days, one month, and three months, indicated that PVDF haptics had better shape recovery capability than PP and extruded three-piece PMMA haptics.

  4. Development and experimental verification of an intraocular scattering model

    Science.gov (United States)

    Jiang, Chong-Jhih; Jhong, Tian-Siang; Chen, Yi-Chun; Sun, Ching-Cherng

    2011-10-01

    An intraocular scattering model was constructed in human eye model and experimentally verified. According to the biometric data, the volumetric scattering in crystalline lens and diffusion at retina fundus were developed. The scattering parameters of cornea, including particle size and obscuration ratio, were varied to make the veiling luminance of the eye model matching the CIE disability glare general formula. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated and compared with that of transparent lenses. The MTF of the intraocular scattering model showed nice correspondence with the data measured by a double-pass experiment.

  5. Controversies in intraocular lens implantation in pediatric uveitis.

    Science.gov (United States)

    Phatak, Sumita; Lowder, Careen; Pavesio, Carlos

    2016-12-01

    Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases of uveitis, multiple factors affect the final outcome. Chronic inflammation and its sequelae such as band keratopathy, posterior synechiae, and cyclitic membranes make surgical intervention more challenging and outcome less certain. Postoperative complications like increased inflammation, glaucoma, posterior capsular opacification, retrolental membranes, and hypotony may compromise the visual outcome. Early refractive correction is imperative in pediatric eyes to prevent amblyopia. The use of contact lenses and intraocular lenses in pediatric uveitic eyes were fraught with complications in the past. Surgical interventions such as vitreo-lensectomy followed by contact lens fitting and small incision cataract surgery followed by different types of intraocular lenses have been utilized, and many reports have been published, albeit in small patient groups. This review analyzes and discusses the existing literature on intraocular lens implantation in cases of pediatric uveitic cataract surgery. PMID:27009616

  6. Effect of chymase on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Maruichi, Midori; Takai, Shinji; Oku, Hidehiro; Sugiyama, Tetsuya; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Ikeda, Tsunehiko; Miyazaki, Mizuo

    2005-11-01

    Chymase is a chymotrypsin-like serine protease that is stored exclusively in the secretory granules of mast cells and converts big endothelins to endothelin-1 (1-31). The aim of this study was to evaluate the effect of chymase on intraocular pressure in rabbits. Chymase injection (3 and 10 mU) resulted in a trend toward increased intraocular pressure and a significant increase in intraocular pressure at a dose of 10 mU compared with the control. A specific chymase inhibitor, Suc-Val-Pro-Phe(P)(OPh)(2), attenuated the ocular hypertension induced by chymase. Endothelin-1 (1-31) also caused ocular hypertension, which was inhibited by a selective endothelin ET(A) receptor antagonist, cyclo(D-Asp-Pro-D-Val-Leu-D-Trp) (BQ-123). Moreover, chymase-induced ocular hypertension was inhibited by BQ-123. These results suggest that chymase influences the regulation of intraocular pressure, and it is likely that the formation of endothelin-1 (1-31) and subsequent activation of endothelin ET(A) receptors are involved in the development of ocular hypertension induced by chymase.

  7. Intraocular inflammation following endotamponade with high-density silicone oil.

    NARCIS (Netherlands)

    Theelen, T.; Tilanus, M.A.D.; Klevering, B.J.

    2004-01-01

    BACKGROUND: The use of a mixture of silicone oil and partially fluorinated alkanes (high-density silicone oil) has recently been suggested as intraocular tamponade in complicated retinal detachment of the inferior quadrants. We describe a series of patients who developed a clinical picture resemblin

  8. Hematoporphyrin derivative photoradiation therapy for the treatment of intraocular tumors

    International Nuclear Information System (INIS)

    Hematoporphyrin derivative (HpD) photoradiation therapy (PRT) is currently being examined for the treatment of intraocular tumors (retinoblastoma and uveal melanoma). HpD is preferentially retained in malignant tissue and tumorcidal action can be induced when HpD is activated with visible red light. Preclinical studies have been conducted using pigmented rabbits having transplanted intraocular tumors. A dye laser system has been used to generate red light (630 nm) for localized irradiation of ocular tissue following I.V. administration of HpD. The authors have previously reported that acute toxicity to normal retina (in the form of retinal necrosis) can be induced by HpD PRT, and that this damage can be limited to the treatment field. The results of current preclinical studies related to long term ocular toxicity, HpD distribution in ocular tissue and intraocular tumor tissue response following HpD PRT are presented. In addition, initial clinical results of intraocular HpD PRT are described

  9. Combined aniridic intraocular lens implantation and vitreoretinal surgery

    Science.gov (United States)

    Mehta, Hijab; Jayadev, Chaitra; Natarajan, S

    2007-01-01

    A 45-year-old man presented with post-traumatic aniridia. We describe the combined surgery done to treat both aniridia and epiretinal membrane simultaneously. A combined aniridia intraocular lens and vitreoretinal surgery was done. The case report highlights the advantage of combined surgery in terms of cost factor and surgical time. PMID:17699956

  10. Combined aniridic intraocular lens implantation and vitreoretinal surgery

    OpenAIRE

    Mehta Hitendra; Mehta Hijab; Jayadev Chaitra; Natarajan S

    2007-01-01

    A 45-year-old man presented with post-traumatic aniridia. We describe the combined surgery done to treat both aniridia and epiretinal membrane simultaneously. A combined aniridia intraocular lens and vitreoretinal surgery was done. The case report highlights the advantage of combined surgery in terms of cost factor and surgical time.

  11. Method for in vitro assessment of straylight from intraocular lenses

    NARCIS (Netherlands)

    Łabuz, Grzegorz; Vargas-Martín, Fernando; van den Berg, Thomas J T P; López-Gil, Norberto

    2015-01-01

    Ocular straylight has been measured by means of psychophysical methods over the years. This approach gives a functional parameter yielding a straight comparison with optically defined light scattering, and the point-spread-function. This is of particular importance when the effect of intraocular len

  12. Development of a ciliary muscle-driven accommodating intraocular lens

    NARCIS (Netherlands)

    Hermans, Erik A.; Terwee, Thom T.; Koopmans, Steven A.; Dubbelman, Michiel; van der Heijde, Rob G. L.; Heethaar, Rob M.

    2008-01-01

    PURPOSE: To develop a ciliary muscle-driven accommodating intraocular lens (IOL) that has a large and predictable range of variable power as a step toward spectacle independence. SETTING: Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands. METHODS:

  13. Effect of chymase on intraocular pressure in rabbits.

    Science.gov (United States)

    Konno, Takashi; Maruichi, Midori; Takai, Shinji; Oku, Hidehiro; Sugiyama, Tetsuya; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Ikeda, Tsunehiko; Miyazaki, Mizuo

    2005-11-01

    Chymase is a chymotrypsin-like serine protease that is stored exclusively in the secretory granules of mast cells and converts big endothelins to endothelin-1 (1-31). The aim of this study was to evaluate the effect of chymase on intraocular pressure in rabbits. Chymase injection (3 and 10 mU) resulted in a trend toward increased intraocular pressure and a significant increase in intraocular pressure at a dose of 10 mU compared with the control. A specific chymase inhibitor, Suc-Val-Pro-Phe(P)(OPh)(2), attenuated the ocular hypertension induced by chymase. Endothelin-1 (1-31) also caused ocular hypertension, which was inhibited by a selective endothelin ET(A) receptor antagonist, cyclo(D-Asp-Pro-D-Val-Leu-D-Trp) (BQ-123). Moreover, chymase-induced ocular hypertension was inhibited by BQ-123. These results suggest that chymase influences the regulation of intraocular pressure, and it is likely that the formation of endothelin-1 (1-31) and subsequent activation of endothelin ET(A) receptors are involved in the development of ocular hypertension induced by chymase. PMID:16253233

  14. Impact factors on intraocular pressure measurements in healthy subjects.

    NARCIS (Netherlands)

    Theelen, T.; Meulendijks, C.F.M.; Geurts, D.; Leeuwen, A.M. van; Voet, N.B.; Deutman, A.F.

    2004-01-01

    AIM: To evaluate whether intraocular pressure (IOP) calculation by applanation tonometry is determined more essentially by the subject's neck position or by neck constriction. METHODS: 23 right eyes of 23 healthy subjects (12 male, 11 female) were included. IOP was measured by applanation tonometry

  15. NEW MATERIAL FOR LOW-COST INTRAOCULAR LENSES

    NARCIS (Netherlands)

    JONGEBLOED, WL; VANDERVEEN, G; KALICHARAN, D; VANANDEL, MV; BARTMAN, G; WORST, JGF

    1994-01-01

    A UV-hardening lacquer material based on polyurethane, used in Philips compact disc lens systems, was tested as suitable material for low-cost intraocular lenses (IOLs). A slightly changed composition (code number I-0.5A) came out as the best and was subsequenly tested, with reference to poly(methyl

  16. Combined aniridic intraocular lens implantation and vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Mehta Hitendra

    2007-01-01

    Full Text Available A 45-year-old man presented with post-traumatic aniridia. We describe the combined surgery done to treat both aniridia and epiretinal membrane simultaneously. A combined aniridia intraocular lens and vitreoretinal surgery was done. The case report highlights the advantage of combined surgery in terms of cost factor and surgical time.

  17. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Simon, V., E-mail: viosimon@phys.ubbcluj.ro [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Radu, T.; Vulpoi, A. [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Rosca, C. [Optilens Clinic of Ophthalmology, 400604 Cluj-Napoca (Romania); Eniu, D. [Iuliu Haţieganu University of Medicine and Pharmacy, Department of Molecular Sciences, 400349 Cluj-Napoca (Romania)

    2015-01-15

    Highlights: • Changes on intraocular lens (IOL) surface after implantation. • Partial opacification of IOL central area. • Elemental composition on IOL surface prior to and after implantation. • First XPS depth profiling examination of the opacifying deposits. • Cell-mediated hydroxyapatite structuring. - Abstract: The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  18. Liquid-crystal intraocular adaptive lens with wireless control

    NARCIS (Netherlands)

    Simonov, A.N.; Vdovine, G.V.; Loktev, M.

    2007-01-01

    We present a prototype of an adaptive intraocular lens based on a modal liquid-crystal spatial phase modulator with wireless control. The modal corrector consists of a nematic liquid-crystal layer sandwiched between two glass substrates with transparent low- and high-ohmic electrodes, respectively.

  19. Controversies in intraocular lens implantation in pediatric uveitis.

    Science.gov (United States)

    Phatak, Sumita; Lowder, Careen; Pavesio, Carlos

    2016-12-01

    Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases of uveitis, multiple factors affect the final outcome. Chronic inflammation and its sequelae such as band keratopathy, posterior synechiae, and cyclitic membranes make surgical intervention more challenging and outcome less certain. Postoperative complications like increased inflammation, glaucoma, posterior capsular opacification, retrolental membranes, and hypotony may compromise the visual outcome. Early refractive correction is imperative in pediatric eyes to prevent amblyopia. The use of contact lenses and intraocular lenses in pediatric uveitic eyes were fraught with complications in the past. Surgical interventions such as vitreo-lensectomy followed by contact lens fitting and small incision cataract surgery followed by different types of intraocular lenses have been utilized, and many reports have been published, albeit in small patient groups. This review analyzes and discusses the existing literature on intraocular lens implantation in cases of pediatric uveitic cataract surgery.

  20. Comparison of a new-generation sectorial addition multifocal intraocular lens and a diffractive apodized multifocal intraocular lens.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Velthoven, M. van; Meulen, I. van der; Nieuwendaal, C.; Mourits, M.; Lapid-Gortzak, R.

    2012-01-01

    PURPOSE: To compare visual, refractive, and satisfactory outcomes between a new-generation sectorial addition multifocal intraocular lens (IOL) (Lentis Mplus LS-312; study group) and a diffractive apodized multifocal IOL (Restor SN6AD1; control group). SETTING: Private practice, Driebergen, and Depa

  1. Intraocular lens exchange-removing the optic intact

    Science.gov (United States)

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange. PMID:27366699

  2. Misdiagnosis induced intraocular lens dislocation in anterior megalophthalmos

    Institute of Scientific and Technical Information of China (English)

    WANG Qi-wei; XU Wen; ZHU Ya-nan; LI Jin-yu; ZHANG Li; YAO Ke

    2012-01-01

    Anterior megalophthalmos (AM) is an uncommon developmental anomaly of the anterior segment of the eye with a constellation of findings that includes enlarged cornea,deep anterior chamber,posterior positioning of the iris and lens,iris stroma atrophy,hypoplasia of iris dilator,pupil displacement,large capsular bag,lens subluxation,prematurely cataract and the tendency to retinal detachment.AM,especially when symptoms are mild,is not an easy disease to diagnose.We present 3 AM cases that were misdiagnosed as congenital cataract with weak zonule and megalocornea.Intraocular lenses (IOLs) dislocated after standard cataract surgeries and subsequent surgery (replacing the dislocated IOLs with iris-claw intraocular lenses) achieved satisfactory outcome.Although rare,AM should be included in the differential diagnosis of enlarged cornea and we recommend implanting Artisan lens in AM patients.

  3. Foldable micro coils for a transponder system measuring intraocular pressure

    Energy Technology Data Exchange (ETDEWEB)

    Ullerich, S.; Schnakenberg, U. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1; Mokwa, W. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1]|[Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany); Boegel, G. vom [Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany)

    2001-07-01

    A foldable transponder system consisting of a chip and a micro coil for measuring intraocular pressure continuously is presented. The system will be integrated in the haptic of a soft artificial intraocular lens. Calculations of planar micro coils with 6 mm and 10.3 mm in diameter show the limits for planar coils with an outer diameter of 6 mm. For the realisation of the transponder system a 20 {mu}m thick coil with an outer diameter of 10.3 mm, an inner diameter of 7.7 mm, 16 turns and a gap of 20 {mu}m between the windings was selected. Measurements show a good agreement between calculated and measured values. Wireless pressure measurements were carried out showing a linear behaviour of the output signal with respect to the applied pressure. (orig.)

  4. Intraocular lens exchange-removing the optic intact.

    Science.gov (United States)

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange.

  5. A CLINICAL STUDY OF INTRAOCULAR PRESSURE CHANGES WITH VECURONIUM BROMIDE AND PANCURONIUM BROMIDE

    Directory of Open Access Journals (Sweden)

    Nagaraja

    2014-04-01

    Full Text Available BACKGROUND: The maintenance of intraocular pressure forms the mainstay of anesthetic management of intraocular surgery. It is desirable to achieve a normal or reduced intraocular pressure before the eye is opened to avoid expulsive hemorrhage and ocular disruption at the time of incision. Therefore the ideal anesthetic technique for intraocular surgery should produce a moderate reduction in intraocular pressure, or maintain intraocular pressure at near normal values and avoid marked fluctuations during surgery (George et al, 1979. The use of suxamethonium is associated with significant rise in intraocular pressure with a peak increase between 2 and 4 minutes following administration and return to base line value after 6 minutes. The outcome of eye surgery, particularly when there is globe injury depends to a large extent on good control of intraocular pressure not only during maintenance, but also at induction of anesthesia. This is usually achieved by use of non-depolarizing muscle relaxant. Pancuronium when used in relatively larger doses is known to have a faster onset of action and also the block may be prolonged. Vecuronium is intermediate acting and free of cardiovascular and other side effects even when used in larger doses. ABACKGROUND: The maintenance of intraocular pressure forms the mainstay of anesthetic management of intraocular surgery. It is desirable to achieve a normal or reduced intraocular pressure before the eye is opened to avoid expulsive hemorrhage and ocular disruption at the time of incision. Therefore the ideal anesthetic technique for intraocular surgery should produce a moderate reduction in intraocular pressure, or maintain intraocular pressure at near normal values and avoid marked fluctuations during surgery (George et al, 1979. The use of suxamethonium is associated with significant rise in intraocular pressure with a peak increase between 2 and 4 minutes following administration and return to base line value

  6. Intraocular Pressure Following Intravitreal Injection of Triamcinolone Acetonide§

    OpenAIRE

    Ansari, Ejaz A; Ali, N

    2008-01-01

    Background: To investigate the intraocular pressure (IOP) response following intravitreal injection of triamcinolone acetonide. Methods: This retrospective consecutive non-comparative case series study included 41 patients (52 eyes) (19 male, 22 female, mean age 64.1 ± 13.44; range 22 – 85 years) with progressive exudative ARMD (n = 10 eyes) or diffuse diabetic macular oedema (42 eyes), who received one or more intravitreal injection(s) of 4 mg triamcinolone acetonide. Results: IOP increased ...

  7. NANOTECHNOLOGY IN THE TREATMENT AND DETECTION OF INTRAOCULAR CANCERS

    OpenAIRE

    Nair, Ashwin; Thevenot, Paul; Hu, Wenjing; Tang, Liping

    2008-01-01

    Tremendous progress in nanotechnology has lead to the development of nanometer-sized objects as medical implants or devices. Many of these nanodevices have recently been tested in many cancer diagnostic and therapeutic applications, such as leukemia, melanoma, breast tumor, prostate tumor, and brain cancer. Despite the increasing importance of nanotechnology in cancer, the potential of these nanodevices in diagnosing and treating intraocular cancers has not been systematically evaluated. This...

  8. Intraocular Pressure And Its Determinants In Tehran Population

    OpenAIRE

    Kashi AH; Fotouhil A; Hashemi H.; Mohammadl K

    2005-01-01

    Background: The aim of this study was to provide data, on the distribution or intraocular pressure (IOP) in Tehran population. Materials and Methods: Through a population-based, cross-sectional study, a total of 4565 Tehran citizens were studied in the Tehran Eye Study. The findings of the participants (n=3834) 10 years and older free of glaucoma diagnosis or suspicion who had undergone applanation tonometry examination are presented. All participants received a standardized protocol included...

  9. Black intraocular lens: another cosmetic approach to leukocoria

    OpenAIRE

    Pedrosa, C; Pina, S.; Azevedo, A.; Pêgo, P; Feijóo, B; Prieto, I

    2012-01-01

    Purpose – To present a case report of a black intraocular lens implantation for cosmetic improvement of a blind eye with leukocoria. Setting – Ophthalmology Department - Professor Dr. Fernando Fonseca Hospital, EPE - Amadora, Lisboa, Portugal Methods – We report a 32-year-old woman who was evaluated because of the undesired cosmetic appearance of her amblyopic left eye with exotropia and leukocoria due to traumatic cataract and total retinal detachment during childhood. The Examination ...

  10. Increased Intraocular Pressure after Extensive Conjunctival Removal: A Case Report

    OpenAIRE

    Lee, Young Rok; Na, Jung Hwa; Kim, Jae Yong; Sung, Kyung Rim

    2013-01-01

    A 50-year-old woman, who had undergone extensive removal of conjunctiva on the right eye for cosmetic purposes at a local clinic 8 months prior to presentation, was referred for uncontrolled intraocular pressure (IOP) elevation (up to 38 mmHg) despite maximal medical treatment. The superior and inferior conjunctival and episcleral vessels were severely engorged and the nasal and temporal bulbar conjunctival areas were covered with an avascular epithelium. Gonioscopic examination revealed an o...

  11. Intraocular gnathostomiasis: A rare case report from Central India

    Science.gov (United States)

    Rawat, Preeti; Gautam, Manushree; Jain, Nikhila C; Jain, Rajdeep

    2016-01-01

    We report the first case of intraocular gnathostomiasis from Central India. A 29-year-old male from Indore, Madhya Pradesh, presented with pain and redness of the right eye since 1 month. Slit lamp examination revealed anterior uveitis, multiple iris atrophic patches, and a live worm hooked on iris. The worm was removed through a small sclerocorneal tunnel. Microscopy confirmed Gnathostoma spinigerum. The patient was treated with oral albendazole and steroids. The case is reported because of its rarity. PMID:27146938

  12. Visual functional changes during acute elevation of intraocular pressure

    Institute of Scientific and Technical Information of China (English)

    Tian-De SHOU

    2006-01-01

    Glaucoma is closely related to elevation of intraocular pressure (IOP). Many studies have done on the effect of chronic elevation of IOP on the retina and optic nerve, but less attention was paid to the effect of acute elevated IOP. Here we briefly review experimental studies on functional changes of the visual system from the retina to the visual cortex under acute elevated IOP condition, which is similar to that of acute primary angle-closure glaucoma.

  13. Successful Removal of Large Intraocular Foreign Body by 25-Gauge Microincision Vitrectomy Surgery

    OpenAIRE

    Hiroshi Kunikata; Megumi Uematsu; Toru Nakazawa; Nobuo Fuse

    2011-01-01

    We describe a new technique for removing a large intraocular foreign body by 25-gauge microincision vitrectomy surgery (25G-MIVS). Noncomparative interventional case series were performed at a single centre. Two patients with a long smooth intraocular vitreal foreign body underwent phacoemulsification and aspiration, intraocular lens implantation, 25G-MIVS, and extraction of the foreign body. The foreign body was removed through a posterior capsulorhexis, anterior continuous curvilinear capsu...

  14. Effects of Mirtogenol® on ocular blood flow and intraocular hypertension in asymptomatic subjects

    OpenAIRE

    Steigerwalt, Robert D; Gianni, Belcaro; Paolo, Morazzoni; Bombardelli, Ezio; Burki, Carolina; Schönlau, Frank

    2008-01-01

    Purpose The most important variable risk factor for developing glaucoma is intraocular hypertension. Timely lowering of high intraocular pressure (IOP) significantly lowers the likelihood of developing glaucoma. The aim of this study was to evaluate the effects of the food supplement Mirtogenol® (Mirtoselect® and Pycnogenol®) on IOP and ocular blood flow in a product evaluation study. Methods Thirty-eight asymptomatic subjects with intraocular hypertension were either given Mirtogenol® (20 su...

  15. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  16. Posterior chamber phakic intraocular lens implantation for high myopia

    Institute of Scientific and Technical Information of China (English)

    沈晔; 杜持新; 顾扬顺; 王竞

    2003-01-01

    Objective To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia.Methods Thirty-nine eyes of twenty patients with high myopia (between-11.75 and-25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6-48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP), corneal reaction and space between crystal lens and intraocular lens (IOLs) were tested.Results Successful implantation was achieved in all patients. Visual acuity without correction greater than 0.5 was found in 34 eyes at 1 day and 3 months postoperatively. Thirty-five eyes maintained a low negative power of refraction (-1.42±1.32 doipters), which did not prevent the patients from most of their daily activities. During 3-48 months' follow-up, refraction was stable and no cornea edema and glaucoma was found. Two eyes of one patient had corticosteroid glaucoma and another eye showed cataractogenesis under anterior capsular membrane.Conclusion Posterior chamber PIOL implantation is predictable, safe, and effective in the correction of high myopia, and its indications should be carefully selected.

  17. Removal of Intralenticular Magnetic Foreign Bodies with Intraocular Magnet

    Institute of Scientific and Technical Information of China (English)

    Yiwen Luo; Zhenfang Wang; Xiaofeng Lin; Shuying Hu

    2003-01-01

    Purpose: To investigate the possibility of conservation of the lens after removal of intralenticular magnetic foreign bodies with intraocular magnet.Methods: Intralenticular magnetic foreign bodies of 15 patients were removed by using an intraocular magnet. The lens of each injury eye was conserved. Follow-up observation of these cases ranged from one to four years.Results: The intralenticular magnetic foreign bodies of 15 patients were successfully removed.The lens of each injury eye was conserved and the transparence of the lens was properly maintained. Sizes of these foreign bodies were measured, ranging from 0.3 mm to 3mm in diameter. The follow-up observation showed that the corrected visual acuity of 14 cases was not changed after operation.Conclusions: The intraocular magnet is very helpful for removal of magnetic foreign bodies from the transparent lens. This magnet allows removing of the foreign body by the surgeon and no damage to the lens was induced during the operation. Thus, maintenance of visual acuity of most of the patients can be achieved.

  18. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Science.gov (United States)

    Simon, V.; Radu, T.; Vulpoi, A.; Rosca, C.; Eniu, D.

    2015-01-01

    The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  19. Comparison of visual performance of multifocal intraocular lenses with same material monofocal intraocular lenses.

    Directory of Open Access Journals (Sweden)

    Tomofusa Yamauchi

    Full Text Available PURPOSE: To compare the visual performance of multifocal intraocular lenses (IOLs and monofocal IOLs made of the same material. METHODS: The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00 or Tecnis® multifocal IOLs (ZMA00 or ZMB00 bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patients who were implanted with Tecnis® multifocal IOLs bilaterally. The monofocal group was an age- and sex-matched control group, and included 85 patients who were implanted with Tecnis® monofocal IOLs bilaterally. Lens opacity grading, the radius of corneal curvature, corneal astigmatism, axial length and the refractive status were measured preoperatively. Pupil size, ocular aberrometry, distance, intermediate and near visual acuity, contrast sensitivity with and without glare and the responses to a quality-of-vision questionnaire were evaluated pre- and postoperatively. RESULTS: The uncorrected near visual acuity was significantly better in the multifocal group, whereas both the corrected intermediate and near visual acuity were better in the monofocal group. Contrast sensitivity (with and without glare was significantly better in the monofocal group. The rate of spectacle dependency was significantly lower in the multifocal group. There were no significant differences between the two groups regarding most items of the postoperative quality-of-vision questionnaire (VFQ-25, with the exception that the patients in the monofocal group reported fewer problems with nighttime driving. CONCLUSIONS: The multifocal IOLs used in this study reduced spectacle dependency more so than monofocal IOLs and did not compromise the subjective visual function, with the exception of nighttime driving.

  20. Keeping an eye on dialysis: the association of hemodialysis with intraocular hypertension.

    Science.gov (United States)

    William, Jeffrey H; Gilbert, Aubrey L; Rosas, Sylvia E

    2015-11-01

    Intraocular hypertension is common during hemodialysis. Dialysis disequilibrium syndrome and intraocular hypertension occur via similar pathophysiologic mechanisms. These mechanisms may contribute to the development of glaucoma and cataracts in a patient population already at high risk for ocular abnormalities, given the common risk factors for chronic kidney disease and impaired aqueous humor outflow. We describe a patient with complicated diabetes mellitus, end-stage renal disease, and recent cataract surgery who developed severe intraocular hypertension during hemodialysis. We recommend increased awareness of the symptoms of intraocular hypertension and subsequent ophthalmologic surveillance in order to prevent long-term visual complications. PMID:26042412

  1. Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique.

    Science.gov (United States)

    Kelkar, Aditya; Shah, Rachana; Kelkar, Jai; Kelkar, Shreekant; Arora, Ekta

    2015-01-01

    Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases.

  2. Coculture with intraocular lens material-activated macrophages induces an inflammatory phenotype in lens epithelial cells.

    Science.gov (United States)

    Pintwala, Robert; Postnikoff, Cameron; Molladavoodi, Sara; Gorbet, Maud

    2015-03-01

    Cataracts are the leading cause of blindness worldwide, requiring surgical implantation of an intraocular lens. Despite evidence of leukocyte ingress into the postoperative lens, few studies have investigated the leukocyte response to intraocular lens materials. A novel coculture model was developed to examine macrophage activation by hydrophilic acrylic (poly(2-hydroxyethyl methacrylate)) and hydrophobic acrylic (polymethylmethacrylate) commercial intraocular lens. The human monocytic cell line THP-1 was differentiated into macrophages and cocultured with human lens epithelial cell line (HLE-B3) with or without an intraocular lens for one, two, four, or six days. Using flow cytometry and confocal microscopy, expression of the macrophage activation marker CD54 (intercellular adhesion molecule-1) and production of reactive oxygen species via the fluorogenic probe 2',7'-dichlorodihydrofluorescein diacetate were examined in macrophages. α-Smooth muscle actin, a transdifferentiation marker, was characterized in lens epithelial cells. The poly(2-hydroxyethyl methacrylate) intraocular lens prevented adhesion but induced significant macrophage activation (p intraocular lens), while the polymethylmethacrylate intraocular lens enabled adhesion and multinucleated fusion, but induced no significant activation. Coculture with either intraocular lens increased reactive oxygen species production in macrophages after one day (p intraocular lens, with hydrophilic surfaces inducing higher activation than hydrophobic surfaces. These findings provide a new method of inquiry into uveal biocompatibility, specifically through the quantification of cell-surface markers of leukocyte activation.

  3. Ocular features of hantavirus infection

    Directory of Open Access Journals (Sweden)

    Mehta Salil

    2007-01-01

    Full Text Available Hantavirus infections are an emerging infectious disease that is beginning to be recognized both worldwide and in India as a cause of hemorrhagic fever that may present as a pulmonary syndrome or as a renal syndrome. Reports of ocular involvement are rare and include transient myopia, low intraocular pressure, conjunctival hemorrhages and changes of intraocular dimensions. Eleven patients (10 males, one female, mean age 37.6 years were admitted to the intensive care unit for pyrexia of unknown origin or hemorrhagic fever following exposure to flood waters. Five male patients (mean age 31.6 years were identified as suffering from hantavirus infection. In one patient, dot and blot intraretinal hemorrhages were seen in the macula of one eye and streak hemorrhages of the disc in the other. In the remaining four, no fundus abnormalities were seen. Ophthalmologists should be aware of these features.

  4. The Effect of Phacoemulsification with Posterior Chamber Intraocular Lens Implantation on Intraocular Pressure and Anterior Chamber Depth

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Mohamadi

    2013-12-01

    Full Text Available Purpose: To evaluate intraocular pressure (IOP and anterior chamber depth (ACD change after phacoemulsification with posterior chamber intraocular lens implantation Methods: In this quasi-experimental study, 84 patients with senile cataract were included. All patients had normal IOP. Patients with traumatic and complicated cataract, any history of uveitis, glaucoma, or other ocular disease or surgery were excluded. Patients underwent phacoemulsification and intraocular lens implantation by the same surgeon. IOP, ACD, and lens thickness were measured and recorded before surgery. IOP was measured at 4, 8 and 12 postoperative weeks and ACD was measured 12 weeks after surgery. Results: The mean preoperative ACD significantly increased from 2.93 mm to 3.54 mm postoperatively (p<0.0001. Mean preoperative IOP was 16.06 mmHg which decreased to 12.01 IOP mmHg, 12.57 mmHg and 12.90 mmHg at 4 weeks, 8 weeks and 12 weeks postoperatively, respectively (all p-values<0.0001. There was a correlation between lens thickness and changes of and ACD after the surgery. There was also a positive correlation between preoperative IOP and IOP reduction after the surgery. Conclusion: Phacoemulsification decreases IOP specially in eyes with higher preoperative IOP and thicker lenses.

  5. Linfoma intra-ocular primário de células tipo B: relato de caso Primary intraocular B-cell lymphoma: case report

    OpenAIRE

    Marcela Cypel; Rubens Belfort Jr; Nilva Moraes; Cristina Muccioli

    2007-01-01

    O linfoma não-Hodgkin primariamente intra-ocular é raro, e caracterizado por uma forma extranodal que pode envolver retina, espaço sub-retiniano, vítreo e nervo óptico. Ocorre independente ou associado ao linfoma do sistema nervoso central e freqüentemente na forma de uveíte de difícil tratamento. Esta forma de linfoma é um dos tumores intra-oculares mais desafiantes de se diagnosticar. Relatamos um caso de linfoma não-Hodgkin intra-ocular difuso de células grandes tipo B numa paciente de 47 ...

  6. Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens

    Science.gov (United States)

    Lee, Shinwook; Choi, Myoung; Xu, Zaiwei; Zhao, Zeyu; Alexander, Elsinore; Liu, Yueai

    2016-01-01

    Purpose The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. Methods The optical characteristics of AcrySof® IQ PanOptix™ (PanOptix) and AcrySof® IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. PMID:27330273

  7. INTRAOCULAR AND SERUM LEVELS OF VASCULAR ENDOTHELIAL GROWTH FACTOR IN ACUTE RETINAL NECROSIS AND OCULAR TOXOPLASMOSIS

    NARCIS (Netherlands)

    Wiertz, Karin; De Visser, Lenneke; Rijkers, Ger; De Groot-Mijnes, Jolanda; Los, Leonie; Rothova, Aniki

    2010-01-01

    Purpose: To determine the intraocular and serum vascular endothelial growth factor (VEGF) levels in patients with acute retinal necrosis (ARN) and compare those with VEGF levels found in patients with ocular toxoplasmosis (OT). Methods: Paired intraocular fluid and serum samples of 17 patients with

  8. Extracapsular cataract extraction : the fate of retained lens material and intraocular lenses

    NARCIS (Netherlands)

    J.P. Kappelhof (Johan)

    1987-01-01

    textabstractThe aim of this study was to examine the fate of the lens material that remains in the eye after an extracapsular cataract extraction both with and without insertion of an intraocular lens. Apart from this, the development of precipitates on the intraocular lenses was morphologically inv

  9. Effect of osteotomies during rhinoplasty on intraocular pressure

    Directory of Open Access Journals (Sweden)

    Amr N. Rabie

    2016-07-01

    Full Text Available Objective: To investigate whether rhinoplasty with osteotomies for the treatment of deformed nose induces changes in intraocular pressure (IOP. Design: Prospective, nonrandomized study. Setting: University-affiliated medical center. Patients: Thirty patients who underwent rhinoplasty with osteotomies for the nose were prospectively enrolled in this study. Fifteen patients had lateral osteotomies with the external perforating technique, and fifteen with an internal continuous technique with periosteal elevation. We excluded patients with diabetes mellitus, hypertension, glaucoma, previous ocular trauma, history of ocular surgery, and previous use of topical corticosteroid eye drops. Main outcome measures: The intraocular pressure (IOP in each patient was measured by Goldmann tonometry preoperatively and postoperatively on days 1, 2, and 7. Results: 23 women and 7 men with a mean age of 27 years were enrolled in the study. The mean ± SD IOP of the eye was 15.69 ± 2.37 mmHg preoperatively. Postoperatively, the mean ± SD IOPs were 15.96 ± 1.92 mmHg on day 1, 15.45 ± 2.55 mmHg on day 2, and 15.72 ± 2.86 mmHg on day 7 (P = .863. Conclusions: Although osteotomes during rhinoplasty caused variations in the IOP compartment, the changes in IOP were not statistically significant. Therefore, rhinoplasty should be a safe surgical procedure with respect to ocular physiological function, however monitoring IOP peri-operatively is advised. To our best knowledge, this is the first clinical trial to determine the effect of rhinoplasty with osteotomy on intraocular pressure.

  10. Repositioning a decentered intraocular lens with 4 haptics.

    Science.gov (United States)

    Liu, Jiewei; Liu, Wenjie; Jia, Yading; Al-Mohtaseb, Zaina N; Wang, Li

    2016-03-01

    We describe a technique to reposition a decentered 4-haptic intraocular lens (IOL). Using an ophthalmic viscosurgical device, the haptic with the worst distortion is dissected from the capsular bag and pulled outside the bag. The opposite haptic (180 degrees away) is also dissected and placed in front of the anterior capsule. The remaining 2 haptics are left in the capsular bag. With this repositioning, the 2 haptics in the bag limit the IOL movement, the 2 haptics outside the bag are no longer distorted, and the IOL is centered. We present 2 cases in which this technique was used to reposition decentered 4-haptic IOLs.

  11. Effect of transscleral neodymium: YAG cyclophotocoagulation on intraocular lenses

    Energy Technology Data Exchange (ETDEWEB)

    Blomquist, P.H.; Gross, R.L.; Koch, D.D. (Baylor College of Medicine, Houston, TX (USA))

    1990-03-01

    A neodymium: YAG laser operating in the thermal mode was used to irradiate isolated intraocular lenses (IOLs) and to perform transscleral cyclophotocoagulation on pseudophakic autopsy eyes to investigate the potential damage to IOL haptics such irradiation may cause. In the isolated IOLs, 70 mJ of energy deformed and partially melted both polymethylmethacrylate (PMMA) and polypropylene haptics. One of the capsular-fixated PC-IOL haptics in an autopsy eye partially melted when irradiated with the maximum energy level (8.8 J), with the aiming beam focused 1 mm posterior to the limbus and maximal posterior focus offset.

  12. Cerebral migration of intraocular silicone oil: an MRI study

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Milea, Dan; Løgager, Vibeke;

    2011-01-01

    for retinal detachment. Methods: Nineteen patients included in this study were referred for silicone oil removal after uncomplicated retinal detachment surgery using internal silicone oil tamponade. Patients with a previous history of intraocular silicone oil, glaucoma or optic pit were excluded. After...... informed consent, the patients underwent magnetic resonance imaging (MRI). Fat saturation as well as short T1 inversion recovery (STIR) sequences combined with water saturation allowed silicone oil to be easily detectable. Results: The mean delay between the silicone oil injection and the MRI procedure...

  13. Delayed Hyphema after Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    A56-year-old man with senile cataract in the left eye underwent extracapsularcataract extraction(ECCE)and posteriorchamber intraocular lens(IOL)implanta-tion on December 19,1988.A 13D J-loopplannar lens was inserted in the ciliary sul-cus.The operation was successful with mildpostoperative response.His corrected visionwas 20/20. He had a follow-up examination onMarch 20,1989.No complication was notedand his vision retained 20/20.In theevening of the same day,the patient sud-denly felt discomfortable and...

  14. Akreos Adapt AO Intraocular Lens Opacification: A Case Report

    Directory of Open Access Journals (Sweden)

    Matteo Forlini

    2013-09-01

    Full Text Available A 79-year-old hyperglycemic patient was referred to the ‘Santa Maria delle Croci' Hospital, Ravenna, Italy. He presented with visual impairment in the right eye. Four years ago, he had had an uneventful cataract surgery in the right eye. We observed an opacification of the intraocular lens (IOL causing significant visual disturbance. The IOL was exchanged. Unfortunately, pathologic analysis was not performed. Patient-related factors such as hyperglycemia and hypertension might have been responsible for the opacification. To our knowledge, there is only one previous report of opacification of the Akreos Adapt AO IOL.

  15. Technology needs for the development of the accommodative intraocular lens

    Science.gov (United States)

    Nishi, Okihiro

    2010-02-01

    Refilling the lens capsule while preserving capsular integrity offers the potential to restore ocular accommodation. There are two persisting problems in capsular bag refilling for possible clinical application: Leakage of the injectable material through the capsular opening and capsular opacification. Numerous attempts for solving these cardinal problems have not been proven to be clinically applicable. Recently, we developed a novel capsular bag refilling procedure using a novel accommodative intraocular lens that serves as an optic as well as a plug for sealing the capsular opening. The procedure and the results of monkey experiments will be presented.

  16. Intraocular pressure in very low birth weight preterm infants and its association with postconceptional age

    Directory of Open Access Journals (Sweden)

    Rodrigo L. Lindenmeyer

    2012-11-01

    Full Text Available OBJECTIVE: To evaluate intraocular pressure in very low birth weight preterm infants and correlate it with postconceptional age. METHODS: The intraocular pressure in a prospective cohort of very low birth weight premature infants (defined as a birth weight <1,500 g and gestational age <32 weeks admitted to Hospital de Clínicas de Porto Alegre , Brazil was evaluated weekly. The evaluated outcome was the variation in the intraocular pressure following changes in the postconceptional age (defined as the gestational age at birth plus the age in weeks at the time of examination in the weeks following preterm birth. Mixed-effects models were used for the statistical analysis to determine the intraocular pressure variation according to postconceptional age, and means and 10th and 90th percentiles were calculated for the intraocular pressure values. RESULTS: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and a mean birth weight of 1,127.7 ± 222.7 g were evaluated. The mean intraocular pressure for the entire cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of all recorded intraocular pressure values were greater than 20 mmHg. The analysis revealed a mean reduction in the intraocular pressure of 0.29 mmHg for each increase in postconceptional age (p = 0.047; 95% CI: -0.58 to -0.0035. The mean intraocular pressure (P10-P90 decreased from 16.3 mmHg (10.5222.16 at 26.3 weeks to 13.1 mmHg (7.28-18.92 at 37.6 weeks of postconceptional age. CONCLUSIONS: The mean intraocular pressure in very low birth weight preterm infants was 14.9 ± 4.5 mmHg. This value decreased 0.29 mmHg per week as the postconceptional age increased.

  17. Analyses of ERG in a patient with intraocular lymphoma

    Directory of Open Access Journals (Sweden)

    Chieko Yasuda

    2010-04-01

    Full Text Available Chieko Yasuda, Shinji Ueno, Mineo Kondo, Nagako Kondo, Chang-Hua Piao, Hiroko TerasakiDepartment of Ophthalmology, Nagoya University School of Medicine, Nagoya, JapanPurpose: To follow the changes in the electroretinograms (ERGs in a patient with primary intraocular lymphoma (PIOL who had a complete remission after chemotherapy. Methods: ERGs were recorded in a 41-year-old woman with PIOL during and after complete remission with chemotherapy. The patient was diagnosed with PIOL from both the ocular signs and the medical history of cranial lymphoma.Results: The ERGs were depressed in the subject. The amplitudes of the bright white flash b-waves were smaller than the a-waves, resulting in a “negative type” ERG. Six weeks after the beginning of chemotherapy, the ocular changes had resolved, and the ERGs, although not of the “negative type”, still showed signs that the amplitude had not returned to normal levels.Conclusion: The negative type ERGs indicated that the inner retina had been damaged to a greater extent than the outer retina. In the convalescent stage, when the ocular manifestations were resolved, the ERGs were still not fully recovered. Although only one case was studied, we suggest that ERGs can be used to evaluate and follow patients with a PIOL.Keywords: electroretinogram, primary intraocular lymphoma, uveitis masquerade syndrome

  18. Ultrasound Biomicroscopy of Iris-claw Phakic Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Ayong Yu; Zhende Lin; Xiaoyu Cai; Xiuqi Chen; Shuke Luo; Yonghua Li

    2006-01-01

    Purpose: To study in situ the intraocular position of iris-claw phakic intraocular lens (ICPIOL) in myopic eyes using ultrasound biomicroscopy (UBM).Methods: UBM echograms of the anterior segment were taken preoperatively and 62to 115 days postoperatively in 6 eyes implanted with the Verisys ICPIOL (AMO). The echograms were assessed for the effect of the ICPIOL on iris tissue.Results: The preoperative distance between the corneal endothelium and the lens ranged from 2.96 to 3.09 mm, and the postoperative distance between the ICPIOL and the corneal endothelium, from 1.86 to 2.03 mm. The distance between the lens and the posterior surface of the ICPIOL ranged from 0.61 to 0.76 mm. The distance between the superior, inferior optic edge and the iris ranged from 0.49 to 1.00 mm,0.21 to 0.51 mm respectively. The shortest distance between the ICPIOL haptics and the angle of anterior chamber ranged from 1.25 to 1.65 mm. The indentation of iris tissue by the ICPIOL haptics without pigmentary dispersion and distortion of posterior curvature of iris was observed.Conclusion: Adequate space is maintained between the Verisyse myopic ICPIOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris without pigment erosion and distortion of iris curvature is noted. The ICPIOL implanted in phakic eyes is a safe alternative for treatment of high myopia.

  19. Multifocal Toric Intraocular Lens for Traumatic Cataract in a Child

    Directory of Open Access Journals (Sweden)

    Yanfeng Zeng

    2016-10-01

    Full Text Available A child suffering from traumatic cataract and corneal astigmatism of 2.14 D had a phacoemulsification operation and implantation of a ReSTOR Toric intraocular lens (IOL to correct the astigmatism. The primary outcome measurements were the uncorrected distance visual acuity (UDVA, uncorrected near vision at 40 cm, intraocular pressure, spherical equivalent refraction, residual astigmatism, corneal astigmatism, presence of unusual optical phenomena, and use of spectacles. At 7 months postoperatively, UDVA was maintained between 16/20 and 24/20, near vision was between J1 and J3, residual spherical refraction was 0–0.37 D, and residual refractive cylinder was between 0 and 0.67 D. A multifocal toric IOL can provide the possibility of satisfactory vision for both distant and near conditions without the use of spectacles to meet children’s needs when studying and doing sports. Additionally, binocular vision can be reconstructed. This intervention, therefore, seems to be a satisfactory alternative.

  20. Intraocular lenses and clinical treatment in paediatric cataract

    Directory of Open Access Journals (Sweden)

    Camila Ribeiro Koch Pena

    2015-06-01

    Full Text Available Pediatric cataract is the most common treatable cause of blindness in children. Prevalence, etiology and morphology vary with the socioeconomic development. The treatment goal is to reduce amblyopia, being difficult management especially in unilateral cases. The decision on aphakia or primary intraocular lens should be individualized as well as correction with contact lens or spectacles. The intraocular lens single-piece hydrophobic acrylic are the most implanted in children and the preferably is in the capsular bag. The Sanders-Retzlaff-Kraff theoretic (SRK/T stressing that is described as more predictable, following Holladay I and SRK II and the recommendation is to under correction +6.0 or +8.0 dioptrias expecting the growth of the eye. The posterior capsule opacity is the most frequent complication and varies with the material choice of the lens. Glaucoma is the most serious postoperative complication and depends on the timing of the surgery, primary lens implantation and time of post surgical follow-up. The adherence to occlusion therapy with patching is critical to the visual prognosis and is determined by the child’s age and laterality of the cataract. There was significant improvement in the surgery and in IOLs, however the final visual prognosis is still not desirable.

  1. Diffractive multifocal intraocular lens interferes with intraoperative view

    Directory of Open Access Journals (Sweden)

    Mami Yoshino

    2010-05-01

    Full Text Available Mami Yoshino1, Makoto Inoue1,2, Nae Kitamura1, Hiroko Bissen-Miyajima11Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Tokyo, Japan; 2Kyorin Eye Center, Kyorin University School of Medicine, Tokyo, JapanAbstract: We report an unusual finding during vitreous surgery in an eye implanted with a diffractive multifocal intraocular lens (IOL. A 70-year-old woman reported gradual visual deterioration to 20/40 in the left eye two and a half years after uneventful cataract surgery with implantation of a diffractive multifocal IOL. Funduscopic examination showed an epiretinal membrane (ERM in the left eye. Increased macular traction was believed to cause the visual deterioration. Vitreous surgery with removal of the ERM was performed and triamcinolone acetonide (TA was injected intravitreally to visualize the residual vitreous cortex. Although the ERM was peeled successfully, the ability to focus on the vitreoretinal interface through the IOL required great effort with decreased contrast sensitivity and ghost images of the intravitreal TA crystals. The vision improved to 20/25 4 months postoperatively. Macular surgery can be performed in an eye with a diffractive multifocal IOL; however, decreased contrast sensitivity and ghost images may interfere with the intraoperative view through the diffractive IOL in complicated cases.Keywords: diffractive multifocal intraocular lens, intraoperative view

  2. Posterior Iris Fixated Intraocular Lens for Pediatric Traumatic Cataract

    Science.gov (United States)

    Kavitha, V.; Balasubramanian, Preethi; Heralgi, Mallikarjun M.

    2016-01-01

    Purpose: To evaluate the postoperative visual outcomes and complications of posterior iris fixated intraocular lens (IFIOL) implantation for pediatric traumatic cataract. Methods: A retrospective clinical audit was performed of all the pediatric traumatic cataract patients who underwent lens removal and iris fixated lens implantation due to inadequate capsular support with or without corneal tear repair between January 2009 and December 2013. Data were collected and analyzed on the preoperative and postoperative visual outcomes and complications. Results: Twenty-five children (25 eyes; 21 males and 4 females) were enrolled with the mean age of 11 ± 4.0 years. There were 72% of eyes that underwent primary cataract removal with IFIOL implantation. Twenty-eight percent of eyes underwent corneal tear repair prior to intraocular lens (IOL) implantation. Preoperative best corrected visual acuity (BCVA) was hand motion in 32% eyes, counting fingers in 24%, and perception of light in 44%. Postoperative BCVA of 0-0.2 logarithm of minimum angle of resolution was reported in the 64% of eyes. One eye developed secondary glaucoma, one eye underwent re-enclavation, and none developed retinal complications. Conclusion: Posterior IFIOL implantation resulted in an improved visual outcome, low incidence of postoperative complications, and is a good alternative to other IOL, in the cases of pediatric traumatic cataract without adequate capsular support. PMID:27162456

  3. Survey of Intraocular Antibiotics Prophylaxis Practice after Open Globe Injury in China

    Science.gov (United States)

    Tan, Junlian; Yang, Yao; Yuan, Zhaohui; Lin, Xiaofeng

    2016-01-01

    Purpose To elucidate the Chinese practice of intraocular antibiotics administration for prophylaxis after open globe injury. Methods A cross-sectional questionnaire survey was performed online by scanning a Quickmark (QR) code with smartphones at the 20th Chinese National Conference of Ocular Trauma in November 2014. Results A total of 153 (30.6%) of all participators at the conference responded. Of the respondents, 20.9% were routinely administered with prophylactic intraocular injection of antibiotics at the conclusion of the primary eye repair, and 56.9% were used only in cases with high risk of endophthalmitis development. The intraocular route of delivery was mainly included with intracameral injection (47.9%) and intravitreal injection (42.0%). Cephalosporins (53.8%) and vancomycin (42.0%) were the main choices of antibiotic agents, followed by fluoroquinolones (24.3%), and aminoglycosides (13.4%). Only 21.9% preferred a combination of two or more two drugs routinely. In addition, significantly more respondents from the referral eye hospital (92.7%) replied using intraocular antibiotics injection for prophylaxis compared to those respondents from the primary hospital (69.4%) (p = 0.001, Fisher’s exact test). Conclusions Intraocular antibiotics injection for post-traumatic endophthalmitis prophylaxis is widely used in China. However, the choice of antibiotic agents and the intraocular route of delivery vary. A well-designed clinical trial is needed to establish a standardized protocol of intraocular antibiotics administration for post-traumatic endophthalmitis prophylaxis. PMID:27275777

  4. Survey of Intraocular Antibiotics Prophylaxis Practice after Open Globe Injury in China.

    Directory of Open Access Journals (Sweden)

    Bingsheng Lou

    Full Text Available To elucidate the Chinese practice of intraocular antibiotics administration for prophylaxis after open globe injury.A cross-sectional questionnaire survey was performed online by scanning a Quickmark (QR code with smartphones at the 20th Chinese National Conference of Ocular Trauma in November 2014.A total of 153 (30.6% of all participators at the conference responded. Of the respondents, 20.9% were routinely administered with prophylactic intraocular injection of antibiotics at the conclusion of the primary eye repair, and 56.9% were used only in cases with high risk of endophthalmitis development. The intraocular route of delivery was mainly included with intracameral injection (47.9% and intravitreal injection (42.0%. Cephalosporins (53.8% and vancomycin (42.0% were the main choices of antibiotic agents, followed by fluoroquinolones (24.3%, and aminoglycosides (13.4%. Only 21.9% preferred a combination of two or more two drugs routinely. In addition, significantly more respondents from the referral eye hospital (92.7% replied using intraocular antibiotics injection for prophylaxis compared to those respondents from the primary hospital (69.4% (p = 0.001, Fisher's exact test.Intraocular antibiotics injection for post-traumatic endophthalmitis prophylaxis is widely used in China. However, the choice of antibiotic agents and the intraocular route of delivery vary. A well-designed clinical trial is needed to establish a standardized protocol of intraocular antibiotics administration for post-traumatic endophthalmitis prophylaxis.

  5. Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

    Science.gov (United States)

    Pandey, Suresh K; Apple, David J

    2005-06-01

    Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

  6. A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    Directory of Open Access Journals (Sweden)

    Korenfeld MS

    2016-01-01

    Full Text Available Michael S Korenfeld,1,2 David K Dueker3 1Comprehensive Eye Care, Ltd., 2Department of Ophthalmology and Visual Sciences, Washington University, Washington, MO, USA; 3Hamad Medical Corporation, Doha, Qatar Purpose: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulated eyes. Methods: A thin fluid-filled bladder was constructed from flexible and inelastic plastic sheeting and was connected to a pressure transducer with high pressure tubing. The output of the pressure transducer was sent to an amplifier and recorded. This device was validated by measuring induced pressure in the fluid-filled bladder while digital pressure was applied to one surface, and the other surface was placed directly against a human cadaver eye or in vivo pig eye. The human cadaver and in vivo pig eyes were each cannulated to provide a manometric intraocular pressure control. Results: The measurements obtained with the newly described device were within ~5% of simultaneously measured manometric intraocular pressures in both a human cadaver and in vivo pig eye model for a pressure range of ~15–100 mmHg. Conclusion: This novel noninvasive device is useful for estimating the intraocular pressure transients induced during any form of external globe compression; this is a clinical setting where no other devices can be used to estimate intraocular pressure. Keywords: glaucoma, intraocular pressure, tonometer, ocular compression

  7. Magnetic resonance imaging diagnosis of intraocular lenses. Die kernspintomographische Diagnostik der Hinterkammerlinse

    Energy Technology Data Exchange (ETDEWEB)

    Tosch, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Bleckmann, H. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Kaczmarek, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany))

    1994-09-01

    Intraocular lenses were investigated by MRI to obtain information about the quality of this method. In experimental studies, seven lenses of between 0 and 30 diopters were visualized. By MRI it was possible to differentiate the various diameters of lenses. It was not possible to discriminate the material of the intraocular lenses. After these first studies the eyes of two corpses and eight patients were investigated. Because of the resolution of MRI it was possible to tell the diopter of implanted lenses. However, by use of MRI in the regular position, a tilting or decentration of the intraocular lens was demonstrated. (orig.)

  8. Optical quality of toric intraocular lens implantation in cataract surgery

    Institute of Scientific and Technical Information of China (English)

    Xian-Wen; Xiao; Jing; Hao; Hong; Zhang; Fang; Tian

    2015-01-01

    AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of Acry Sof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes,T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), residual refractive cylinder and intraocular lens(IOL) axis rotation.Objective optical quality were measured using optical quality analysis system(OQAS Ⅱ, Visiometrics, Spain),included the cutoff frequency of modulation transfer function(MTFcutoff), objective scattering index(OSI),Strehl ratio, optical quality analysis system value(OV)100%, OV 20% and OV 9% [the optical quality analysis system(OQAS) values at contrasts of 100%, 20%, and 9%].RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18 ±0.11 and 0.07 ±0.08 log MAR; the mean residual refractive cylinder was 0.50 ±0.29 D; the mean toric IOL axis rotation was 3.62 ±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV9% were 22.862 ±5.584, 1.80 ±0.84, 0.155 ±0.038, 0.76 ±0.18,0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%,OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different(P >0.05), except the residual refractive cylinder(P <0.05).CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of Acry Sof toric IOL implantation. Implantation of an Acry Sof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.

  9. Change in Intraocular Pressure During Point-of-Care Ultrasound

    Directory of Open Access Journals (Sweden)

    Berg, Cameron

    2015-03-01

    Full Text Available Introduction: Point-of-care ocular ultrasound (US is a valuable tool for the evaluation of traumatic ocular injuries. Conventionally, any maneuver that may increase intraocular pressure (IOP is relatively contraindicated in the setting of globe rupture. Some authors have cautioned against the use of US in these scenarios because of a theoretical concern that an US examination may cause or exacerbate the extrusion of intraocular contents. This study set out to investigate whether ocular US affects IOP. The secondary objective was to validate the intraocular pressure measurements obtained with the Diaton® as compared with standard applanation techniques (the Tono-Pen®.   Methods: We enrolled a convenience sample of healthy adult volunteers. We obtained the baseline IOP for each patient by using a transpalpebral tonometer. Ocular US was then performed on each subject using a high-frequency linear array transducer, and a second IOP was obtained during the US examination. A third IOP measurement was obtained following the completion of the US examination. To validate transpalpebral measurement, a subset of subjects also underwent traditional transcorneal applanation tonometry prior to the US examination as a baseline measurement. In a subset of 10 patients, we obtained baseline pre-ultrasound IOP measurements with the Diaton® and Tono-Pen®, and then compared them.   Results: The study included 40 subjects. IOP values during ocular US examination were slightly greater than baseline (average +1.8mmHg, p=0.01. Post-US examination IOP values were not significantly different than baseline (average -0.15mmHg, p=0.42. In a subset of 10 subjects, IOP values were not significantly different between transpalpebral and transcorneal tonometry (average +0.03mmHg, p=0.07.   Conclusion: In healthy volunteer subjects, point-of-care ocular US causes a small and transient increase in IOP. We also showed no difference between the Diaton® and Tono-Pen® methods

  10. Opacificação tardia de lente intra-ocular de polimetilmetacrilato (PMMA: relato de caso Late opacification of a polymethylmethacrylate (PMMA intraocular lens: case report

    Directory of Open Access Journals (Sweden)

    Otacílio de Oliveira Maia Júnior

    2005-10-01

    Full Text Available O implante das lentes intra-oculares foi grande avanço na reabilitação visual de pacientes submetidos à cirurgia de extração da catarata. Contudo, os materiais utilizados na fabricação destas lentes, apesar de terem boa biocompatibilidade, são passíveis de alterações posteriores ao implante. No presente estudo, os autores relatam um caso raro de opacificação tardia de lente de polimetilmetacrilato, material inerte e bem tolerado intra-ocularmente, discutindo aspectos importantes no manejo desta complicação, bem como indicação de explante e substituição da lente.The use of intraocular lenses was a great advance in visual recovery after cataract surgery. Although usually with good biocompatibility, some alterations in the intraocular lens material may occur after implantation. Polymethylmethacrylate was the first intraocular lens material to be used on a large scale and assumed to be inert and well-tolerated. We present a rare case of late opacification of a polymethylmethacrylate lens, discussing important aspects of its management such as the indication for intraocular lens exchange.

  11. Intraocular electro-optic lens with ciliary muscle controlled accommodation.

    Science.gov (United States)

    Doornaert, Dries; Glorieux, Christ; De Gersem, Herbert; Puers, Robert; Spileers, Werner; Blanckaert, Johan

    2013-01-01

    In this paper a concept is proposed of an intraocular lens implant with electro-optic accommodation of a variable-focus hybrid liquid-crystal-based lens. The dioptric strength of the lens is electronically controlled by a signal that is derived from the change of inductance of a sensing coil due to a marker implanted in the nearby contracting or decontracting ciliary muscle. Analytical, numerical and experimental results are reported on the dependency of the frequency of a Colpitts oscillator circuit on the location of a nearby conductive marker. A concept is also reported on the use as an electro-optic lens of a device based on a liquid crystal in planar alignment, which is held between a flat and a curved window coated with optically transparent and electrically conductive layers. PMID:24110406

  12. Laboratory analyses of two explanted hydrophobic acrylic intraocular lenses

    Directory of Open Access Journals (Sweden)

    Yunhai Dai

    2014-01-01

    Full Text Available Two three-piece hydrophobic acrylic intraocular lenses (IOLs were explanted from two patients at 7 and 9 years, respectively, after implantation, because of poor fundus visualisation and/or a clinically significant decrease in visual acuity related to their opacified IOLs. In addition to light microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy, confocal laser scanning microscopy was used for the first time to observe the explanted IOLs. The clinical aspect seemed to correspond to the phenomenon of surface light scattering, while laboratory analyses showed dense glistenings in the central layer of the IOL optic, which had no change next to the surface. Further studies on these phenomena are needed.

  13. Ectopic intraocular lens: An unusual complication of cataract surgery

    Directory of Open Access Journals (Sweden)

    Mehul A Shah

    2014-01-01

    Full Text Available We wish to report an unusual complication of intraocular lens (IOL insertion following uneventful phacoemulsification. After successful phacoemulsification surgery, a hydrophobic acrylic IOL was loaded in the injector for insertion into the capsular bag. During insertion, the IOL inadvertently extended into the corneal stromal lamella. The complication was recognized at a late stage, and the foldable acrylic lens was retrieved and reinserted correctly in the bag. The anterior chamber was made viscoelastically taut and was maintained in this state for 10 min, followed by a routine viscoelastic wash and air bubble injection. Cornea was slightly edematous with stromal haze, and the corneal thickness was 908 μm. At the 1-month follow-up visit, the patient′s vision was 20/40, the stromal haze had subsided, the corneal thickness was 572 μm, and the patient was comfortable. Though it was unknown complication, following proper management patient recovered satisfactorily.

  14. Central corneal thickness and intraocular pressure in premature infants.

    Science.gov (United States)

    Sekeroglu, Mehmet Ali; Hekimoglu, Emre; Petricli, İkbal Seza; Karakaya, Jale; Ozcan, Beyza; Yucel, Husniye; Kavurt, Aysen Sumru; Bas, Ahmet Yagmur

    2015-12-01

    To evaluate the central corneal thickness (CCT) and intraocular pressure (IOP) of premature infants and to document correlation of them with gestational age, chronological age, and birth weight of infants. Using a hand-held applanation tonometer and a portable pachymeter, IOP and CCT of 170 premature infants were measured just before initial retinopathy of prematurity screening examination and re-measured 4 weeks after the first visit. The CCT and IOP were positively correlated during the first (r = 0.616, p premature infants with a smaller gestational age were found to be higher (p Premature infants with smaller gestational age have higher CCT and IOP values when compared to older infants. These values tend to become lower 4 weeks after the first examination as infants become older. The CCT and IOP were positively correlated with each other and both were negatively correlated with gestational age, chronological age, and birth weight during first and second visits. PMID:26286757

  15. Bionic intraocular lens with variable focus and integrated structure

    Science.gov (United States)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei; Xiang, Ke

    2015-10-01

    This paper proposes a bionic accommodating intraocular lens (IOL) for ophthalmic surgery. The designed lens has a solid-liquid mixed integrated structure, which mainly consists of a support ring, elastic membrane, rigid lens, and optical liquid. The lens focus can be adjusted through the deformation of the lens front surface when compressed. The integrated structure of the IOL is presented, as well as a detailed description of the lens materials and fabrication process. Images under different radial pressures are captured, and the lens deformation process, accommodating range, density, and optical property are analyzed. The designed lens achieves a 14.6 D accommodating range under a radial pressure of 51.4 mN and a 0.24 mm alteration of the lens outer radius. The deformation property of the lens matches well with the characteristic of the eye and shows the potential to help patients fully recover their vision accommodation ability after the cataract surgery.

  16. [To guard against mistakes in selection of intraocular lenses].

    Science.gov (United States)

    He, Shou-zhi

    2008-04-01

    Development of different kinds of new intraocular lenses (IOL) provide more selections to meet various clinical requirements, which may plays an active role in making cataract surgery more perfectible. But there are many misunderstandings about how to select the proper IOL. For example, "the expensive one is the best one", "new product is absolutely perfect", and so on. Some surgeons prefer more practice and ignore the summary of the experiences. Someone unilaterally exaggerates some special function of IOL When selecting the IOL, it is a common challenge for us to fully consider the patients needs, and properly manage the relationship between the basic need and special need, and to avoid fanaticism, and provide the best benefits to the patients. PMID:18844010

  17. The accute effects of resistance exercise on intraocular pressure

    Directory of Open Access Journals (Sweden)

    Vieira Geraldo Magela

    2003-01-01

    Full Text Available PURPOSE: To study intraocular pressure (IOP variations in healthy volunteers after weight lifting, in the supine position. METHODS: A descriptive study was designed. Thirty-four individuals were preselected for this study, and a group of 25 volunteers fulfilled the inclusion criteria for joining the initial phase of this research. All of them were healthy without glaucoma. They were asked to lift an 85% top load in the supine position for 8 times. IOP was measured before and after the exercise. Student's t test was used to analyze the IOP variations. RESULTS: A small, but significant IOP decrease (1.61 mmHg was obtained after exposing 25 individuals (49 eyes to a specific physical effort. CONCLUSIONS: After a session of weight lifting in the supine position with 85% top load for 8 repetitions, there is a small, but significant IOP decrease.

  18. Intraocular penetration of sequentially instilled topical moxifloxacin, gatifloxacin, and levofloxacin

    Directory of Open Access Journals (Sweden)

    Koji Sugioka

    2009-10-01

    Full Text Available Koji Sugioka1, Masahiko Fukuda1, Shohei Komoto1, Motoki Itahashi1, Masakazu Yamada2, Yoshikazu Shimomura11Department of Ophthalmology, Kinki University School of Medicine, Osaka-Sayama City, Osaka, Japan; 2Division for Vision Research, National Institute of Sensory Organs, National Tokyo Medical Center, Tokyo, JapanPurpose: The objective of the study was to compare the intraocular penetration levels of the newer fluoroquinolones, moxifloxacin, gatifloxacin, and levofloxacin in the rabbit’s cornea, aqueous humor, and conjunctiva after topical instillation.Methods: 0.5% moxifloxacin, 0.3% gatifloxacin, and 0.5% levofloxacin were instilled in random sequence in both eyes of nine New Zealand White rabbits at two-minute intervals. Instillation was repeated every 15 minutes for a total of three drops of each fluoroquinolone per eye. Three additional animals had only moxifloxacin instilled bilaterally using the same schedule. Sixty minutes after the final instillation, the rabbits were sacrificed for determination of corneal, aqueous humor, and conjunctival fluoroquinolone concentrations using highperformance liquid chromatography.Results: Moxifloxacin achieved significantly higher concentrations than levofloxacin and gatifloxacin in the cornea (P = 0.0102 and P = 0.0006, respectively, aqueous humor (P = 0.0015 and P < 0.0001, respectively, and conjunctiva (P = 0.0191 and P = 0.0236, respectively. Conclusions: 0.5% moxifloxacin eyedrops provided superior intraocular penetration in rabbits’ eyes compared with the two other fluoroquinolones, 0.5% levofloxacin and 0.3% gatifloxacin.Keywords: fluoroquinolone, gatifloxacin, levofloxacin, moxifloxacin, penetration, rabbit

  19. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  20. Design of a Test Bench for Intraocular Lens Optical Characterization

    Science.gov (United States)

    Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  1. A previsibilidade biométrica nas lentes intra-oculares multifocais Biometric predictability in multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Augusto Cézar Lacava

    2007-08-01

    Full Text Available OBJETIVO: Apresentar a previsibilidade biométrica, avaliando a refração pós-operatória e acuidade visual (AV, em olhos submetidos a implante de lente intra-ocular multifocal. MÉTODOS: Estudo retrospectivo em 88 olhos de 50 pacientes, submetidos à facoemulsificação com implante de lentes multifocais, de três marcas comerciais ReSTOR, ReZoom e Tecnis. No exame biométrico foram utilizados a biometria óptica ou biometria por interferometria de baixa coerência, associada ao uso de tomógrafo de segmento anterior e à fórmula biométrica Holladay II. Com a refração pós-operatória, acuidade visual e a dioptria da LIO implantada, segundo a fórmula Holladay II, calculamos o valor da lente intra-ocular (LIO a ser implantada caso utilizássemos as fórmulas SRKT e Haigis. Os resultados foram avaliados por métodos estatísticos. RESULTADOS: Todos os olhos obtiveram AV igual ou maior a 20/40 e J3 sem correção. As fórmulas Holladay II, SRKT e Haigis apresentaram performance semelhante em todos os grupos de olhos. CONCLUSÃO: A utilização de novas tecnologias, como a biometria óptica e fórmulas de última geração, favorecem a obtenção do resultado refracional almejado com grande previsibilidade.PURPOSE: To present biometric predictability, evaluating postoperative refraction and visual acuity in eyes submitted to multifocal intraocular lens implantation. METHODS: Retrospective study in 88 eyes of 50 patients, submitted to phacoemulsification with multifocal lens implant of three commercial brands: ReSTOR, ReZoom and Tecnis. For biometric examination were used: optic biometry associated to the use of tomography of anterior segment and Holladay II biometric formula. With postoperative refraction, visual acuity and implanted IOL, according to Holladay II formula, we calculated the value of IOL to be implanted in case we used SRKT and Haigis formulas. The results were evaluated according to statistical methods. RESULTS: All eyes

  2. New Management of Malignant Glaucoma by Phacoemulsification with Posterior Chamber Foldable Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    GeJian; GuoY

    1999-01-01

    Objective:To investigate the feasibility of phacoemulsification with posterior chamber foldable intraocular lens implantation in the management of malignant glaucoma. Patients and Methods:Fourteen patients with malignant glaucoma diagnosed in the Department of Glaucoma were enrolled in the study.12 patients developed malignant glaucoma after filtration surgery.1 developed after peripheral iridectomy.1 patient developed malignant glaucoma without any clear cause.Cataract phacoemulsification was performed.Posterior chamber intraocular foldable lens was implanted in 10 cases of patients.Results:All 14 patients were cured wiht normal intraocular pressure,normal anterior chamber depth and increased visual acuity.Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation is a good alternative in treating malignant glaucoma.

  3. The Experimental Study on Implantation of Intraocular Lens in Different Animals

    Institute of Scientific and Technical Information of China (English)

    WANGGui-qin; PENGXiu-jun; GUHan-qing

    2004-01-01

    To prevent the complications in cataract surgeries, the eyes of rabbits and monkeys were implanted with intraocular lens for 360 days. Methods: The eyes of the rabbits were performed with phacoemulsification and soft intraocular lens implantation. The eyes of the monkeys were performed with extracapsular cataract extraction and hard intraocular lens implantation. Results: The postoperative reactions included corneal edema, anterior chamber exudation, posterior capsule opacification and so on. The complications in the eyes of the rabbits were more than that in the eyes of the monkeys. Conclusion: The different postoperative reactions happened in different animals. In clinical the choice of the operative method and intraocular lens depended on the case in order to acquire the best sight.

  4. Intraocular pressure-lowering effect of oral paracetamol and its in vitro corneal penetration properties

    OpenAIRE

    Mohamed N; Meyer D

    2013-01-01

    Nabiel Mohamed, David MeyerDivision of Ophthalmology, Faculty of Medicine and Health Sciences, University of Stellenbosch, Cape Town, South AfricaBackground: Several studies have confirmed the ability of cannabinoids to reduce intraocular pressure. Experimental data recently demonstrated unequivocally that the analgesic effect of paracetamol is due to its indirect action on cannabinoid receptors. The question then arises as to whether paracetamol can reduce intraocular pressure via its effect...

  5. New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics.

    Science.gov (United States)

    Liu, He-Ting; Jiang, Zheng-Xuan; Tao, Li-Ming

    2016-01-01

    The study was to report a new two-point scleral-fixation technique for foldable intraocular lenses with four haptics. Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points. The postoperative best-corrected visual acuities (BCVAs) of all patients were significantly better than their preoperative BCVA. The results demonstrate that two-point, scleral fixations of foldable, intraocular lenses might be practicable and effective.

  6. Short-term intraocular pressure changes after intravitreal injection of bevacizumab in diabetic retinopathy patients

    OpenAIRE

    Farhood, Qasim

    2014-01-01

    Qasim Kadhim Farhood,1 Sinan Mohammad Twfeeq21College of Medicine, Babylon University, Babylon; 2Al-Jumhori teaching hospital, Mosul, IraqBackground: This study examined the changes in short-term intraocular pressure (IOP) in a prospective series of patients undergoing intravitreal bevacizumab injection. The aim was to evaluate the frequency and predictive factors related to intraocular pressure (IOP) elevation in patients receiving intravitreal bevacizumab.Patients and methods: This study in...

  7. Followup of a Dog with an Intraocular Silicone Prosthesis Combined with an Extraocular Glass Prosthesis

    OpenAIRE

    Gwendolyna Romkes; Johanna Corinna Eule

    2012-01-01

    Because of unpredictable corneal changes, evisceration and implantation of a silicone prosthesis does not always lead to a satisfying cosmetic result. This paper describes the use of an intraocular silicone prosthesis in combination with an extraocular glass prosthesis and shows a followup of two and a half years in a nonexperimental study. An intraocular silicone prosthesis was implanted after evisceration of the left eye in a five-month-old Bernese mountain dog. A glass prosthesis was fitte...

  8. A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    OpenAIRE

    Korenfeld MS; Dueker DK

    2016-01-01

    Michael S Korenfeld,1,2 David K Dueker3 1Comprehensive Eye Care, Ltd., 2Department of Ophthalmology and Visual Sciences, Washington University, Washington, MO, USA; 3Hamad Medical Corporation, Doha, Qatar Purpose: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulat...

  9. Intraocular Foreign Body. A Case Presentation Cuerpo extraño intraocular. Presentación de un caso

    Directory of Open Access Journals (Sweden)

    Inés Zamora Galindo

    2012-05-01

    Full Text Available

    Eye trauma is a common cause of visual impairment, mainly of monocular blindness in 33 to 40% of cases. The case of a 40 years old female patient of rural origin, who attended Ophthalmology consultation at the Dr. Gustavo Aldereguía Lima General University Hospital because of blurry vision in her right eye three months after a trauma, is presented. An accurate medical record, ophthalmologic examination and appropriate diagnostic methods allowed identifying an intraocular foreign body. The patient underwent surgery and evolved favorably. Her best corrected visual acuity is 0.7 in the right eye and 1.0 in the left eye.

    Los traumatismos oculares son una causa común de deficiencia visual, principalmente de ceguera monocular en el 33 al 40 % de los casos. Se presenta el caso de un paciente de 40 años y procedencia rural, que acudió a consulta de Oftalmología del Hospital General Universitario Dr. Gustavo Aldereguía Lima por presentar visión borrosa del ojo derecho, tres meses después de haber sufrido un traumatismo. Una correcta anamnesis, examen oftalmológico y métodos diagnósticos adecuados lograron la identificación de un cuerpo extraño intraocular. El paciente fue sometido a cirugía y evolucionó favorablemente; su agudeza visual mejor corregida es de 0,7 en el ojo derecho y de 1,0 en el izquierdo.

  10. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  11. Intraocular pressure variations during zygomatic fracture reduction and fixation: a clinical study.

    LENUS (Irish Health Repository)

    Murray, Dylan J

    2012-02-03

    BACKGROUND: The reduction of midface fractures has been associated with the rare but devastating complication of blindness. An increase in intraocular pressure is important in the mechanism of blindness in this setting. In this study, the authors assessed the intraocular pressure in patients who underwent zygomatic fracture reduction (with or without fixation). METHODS: Using applanation tonometry, 29 patients underwent intraocular pressure measurements before, during, and after fracture fixation. The contralateral pressures were measured and used as the control. RESULTS: There were 29 patients with a mean age of 35 years, and the mean time to surgery was 5 days. Preoperatively, all patients had normal intraocular pressures and normal visual acuity. All patients underwent a Gillies lift and 18 patients required open reduction and fixation of the frontozygomatic suture (n = 4) or the infraorbital margin (n = 2), and the remainder (n = 12) required fixation of both points. There was no statistically significant increase in the intraocular pressures following the reduction of uncomplicated zygomatic fractures. Statistically significant pressure reductions were noted immediately after reduction and fixation. CONCLUSIONS: The surgical reduction of uncomplicated zygomatic fractures has no adverse effect on the intraocular pressure. It is the authors\\' opinion that adjunctive measures to reduce the pressures are unnecessary.

  12. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Fukumoto M

    2013-07-01

    Full Text Available Masanori Fukumoto, Tsunehiko Ikeda, Tetsuya Sugiyama, Mari Ueki, Takaki Sato, Eisuke Ishizaki Department of Ophthalmology, Osaka Medical College, Takatsuki City, Japan Abstract: This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. Keywords: Alagille syndrome, cataract, retina, surgery

  13. A possible coincidence of cytomegalovirus retinitis and intraocular lymphoma in a patient with systemic non-Hodgkin’s lymphoma

    Directory of Open Access Journals (Sweden)

    Svozílková Petra

    2013-01-01

    Full Text Available Abstract Purpose To present a possible coincidence of cytomegalovirus retinitis and intraocular lymphoma in a patient with systemic non-Hodgkin’s lymphoma. Case presentation A 47-year-old woman presented with decreased visual acuity associated with white retinal lesions in both eyes. A history of pneumonia of unknown aetiology closely preceded the deterioration of vision. Five years previously the patient was diagnosed with follicular non-Hodgkin’s lymphoma. She was treated with a chemotherapy regimen comprised of cyclophosphamide, adriamycin, vincristin, and prednisone with later addition of the anti-CD20 antibody rituximab. She experienced a relapse 19 months later with involvement of the retroperitoneal lymph nodes, and commenced treatment with rituximab and 90Y-ibritumomab tiuxetan. A second relapse occurred 22 months after radioimmunotherapy and was treated with a combination of fludarabine, cyclophosphamide, and mitoxantrone followed by rituximab. The patient experienced no further relapses until the current presentation (April, 2010. Pars plana vitrectomy with vitreous fluid analysis was performed in the right eye. PCR testing confirmed the presence of cytomegalovirus in the vitreous. Atypical lymphoid elements, highly suspicious of malignancy were also found on cytologic examination. Intravenous foscarnet was administered continually for three weeks, followed by oral valganciclovir given in a dose of 900 mg twice per day. In addition, the rituximab therapy continued at three monthly intervals. Nevertheless, cessation of foscarnet therapy was followed by a recurrence of retinitis on three separate occasions during a 3-month period instigating its reinduction to the treatment regime after each recurrence. Conclusions Cytomegalovirus retinitis is an opportunistic infection found in AIDS patients as well as in bone marrow and solid organ transplant recipients being treated with systemic immunosuppressive drugs. This case presents a less

  14. Classification of intraocular lens and its intraocular biocompatibility%人工晶体分类及其在眼内的生物相容性

    Institute of Scientific and Technical Information of China (English)

    胡莉群

    2009-01-01

    目的:通过手术摘除自身浑浊晶体,植入人工晶体是治疗白内障的惟一有效措施.文章总结人工晶体材料的研究进展,为今后的临床应用和研究提供参考.方法:应用计算机检索1997/2009 Medline数据库、中国期刊网和万方数据库、SpringerLink数据库和ScienceDirect数据库.结果:共有25篇文章符合纳入标准.文章主要从人工晶体的发展现状、分类、生物相容性、人工晶体的并发症和发展趋势进行阐述.人工晶体按照硬度,可以分为硬质人工晶体和软性人工晶体.丙烯酸人工晶体比硅凝胶人工晶体的生物相容性更好.人工晶状体脱位是白内障摘除联合人工晶状体植入术后较常见的并发症之一.注入式人工晶体材料是今后研究的方向.结论:人工晶体植入眼内作为一种异物,机体对此产生反应是机体正常的防御现象.人工晶体材料和设计应充分的考虑人工晶体的生物相容性、术后视功能、调节功能、光保护等方面性能.保证术后的疗效和减少并发症的发生,使白内障患者获得更高质量的视力康复.%OBJECTIVE: The sole effective measure for cataract is replaced the epinephelos lens with intraocular lens. So, in this paper, we summarize the research process of intraocular lens, which can provide a reference for further study. METHODS: Medline, China Journal Net, Wanfang Data, SpringerLink, and ScienceDirect database were computer retrieved from 1997 to 2009. RESULTS: A total of 25 papers were included. All the papers were explained intraocular lens from the aspect of current situation, complication following implantation, and develop tendency. According to hardness, intraocular lens can be divided into hard intraocular lens and soft intraocular lens. Acrylic intraocular lenses showed better biocompatibility than the silicone intraocular lenses. In addition, the common complication following implantation was dislocation of lens. Therefore

  15. Comparison of dose calculation methods for brachytherapy of intraocular tumors

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, Mark J.; Chiu-Tsao, Sou-Tung; Finger, Paul T.; Meigooni, Ali S.; Melhus, Christopher S.; Mourtada, Firas; Napolitano, Mary E.; Rogers, D. W. O.; Thomson, Rowan M.; Nath, Ravinder [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Quality MediPhys LLC, Denville, New Jersey 07834 (United States); New York Eye Cancer Center, New York, New York 10065 (United States); Department of Radiation Oncology, Comprehensive Cancer Center of Nevada, Las Vegas, Nevada 89169 (United States); Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Department of Radiation Physics, University of Texas, M.D. Anderson Cancer Center, Houston, Texas 77030 (United States) and Department of Experimental Diagnostic Imaging, University of Texas, M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Physics, Elekta Inc., Norcross, Georgia 30092 (United States); Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6 (Canada); Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06520 (United States)

    2011-01-15

    Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off

  16. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  17. Clinical study of customized aspherical intraocular lens implants

    Institute of Scientific and Technical Information of China (English)

    Lie-Xi; Jia; Zhao-Hui; Li

    2014-01-01

    AIM:To compare if there is an improvement in visual functions with age-related cataracts between patients receiving a aspherical intraocular lens(IOL) based on corneal wavefront aberration and patients randomly assigned lenses.METHODS:A total of 124 eyes of 124 patients with age-related cataracts were placed in experimental group and a group receiving randomly assigned(RA) lenses.The experimental group was undergone Pentacam corneal spherical aberration measurement before surgery; the targeted range for residual total spherical aberration after surgery was set to 0-0.3 μm. Patients with a corneal spherical aberration <0.3 μm were implanted with a zero-spherical aberration advanced optics(AO) aspherical IOL and patients with an aberration ≥0.3 μm received a Tecnis Z9003 aspherical lens in experimental group. RA patients were randomly implanted with an AO lens or a Tecnis Z9003 lens. Three months after surgery total spherical aberration, photopic/mesopic contrast sensitivities, photopic/mesopic with glare contrast sensitivities, and logMAR vision were measured.RESULTS:Statistical analysis on logMAR vision showed no significant difference between two groups(P =0.413). The post-surgical total spherical aberration was 0.126 ±0.097 μm and 0.152 ±0.151 μm in the experimental and RA groups, respectively(P =0.12). The mesopic contrast sensitivities at spatial frequencies of 6,12 and 18 c/d in the experimental group were significantly higher than of the RA group(P =0.00; P =0.04;P =0.02). The mesopic with glare contrast sensitivity in the experimental group at a spatial frequency of 18 c/d was also significantly higher vs the RA group(P =0.01).CONCLUSION:Pre-surgical corneal spherical aberration measurement in cataract patients followed bycustomized selection of aspherical IOL implants improved mesopic contrast sensitivities at high spatial frequencies, and thus is a superior strategy compared to the random selection of aspherical intraocular lens implants.

  18. Mechanisms for vasopressin effects on intraocular pressure in anesthetized rats

    Science.gov (United States)

    Balaban, C. D.; Palm, D. E.; Shikher, V.; Searles, R. V.; Keil, L. C.; Severs, W. B.

    1997-01-01

    Continuous intracameral infusions of a balanced salt solution (0.175 microliter min-1) have been reported to raise intraocular pressure (IOP) in anesthetized rats. Palm et al. (1995) previously reported that this effect was attenuated significantly by inclusion of arginine-vasopressin (AVP, 10 ng 0.175 microliter-1) in the infusate. This study used experimental and computer simulation methods to investigate factors underlying these changes in IOP. First, constant intracameral infusions of artificial cerebrospinal fluid (aCSF) at different fixed rates (0.049-0.35 microliter min-1) were used to estimate the outflow resistance. Secondly, IOP responses were measured during an 2 hr intracameral infusion of either aCSF or AVP that was the sum of a small constant component (0.05 microliter min-1) and a larger periodic component (0.25 microliter min-1, cycling for 4 min on, then 4 min off); the mean infusion rate was 0.175 microliter min-1. As shown previously for 0.175 microliter min-1 constant infusions, the periodic aCSF infusion induced a significant rise in IOP that was attenuated by AVP administration. Complex demodulation analysis and the estimated gain parameter of a second order transfer function fit to the periodic responses indicated that outflow resistance increased significantly during the infusions in both aCSF and AVP groups, but that the indices of resistance did not differ significantly between aCSF and AVP infused eyes. This finding implies that changes in outflow resistance do not explain the difference in IOP responses to intracameral aCSF and AVP. The two responses differed significantly, though, in damping factors, such that the aCSF responses were considerably more underdamped than the AVP responses. It is hypothesized that aCSF-induced increase in IOP reflects both (1) a small component reflecting increased outflow resistance and (2) a larger non-resistive component. Since the non-resistive component is insensitive to pretreatment with acetazolamide

  19. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = −0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type

  20. Resultados da troca de lente intra-ocular de hidrogel opacificada

    Directory of Open Access Journals (Sweden)

    Salera Cristina Moreira

    2004-01-01

    Full Text Available OBJETIVO: Avaliar os resultados da explantação e substituição das lentes intra-oculares (LIO de hidrogel opacificadas. MÉTODOS: Foram analisados retrospectivamente os prontuários de 12 pacientes (15 olhos submetidos à explantação e substituição das lentes intra-oculares de hidrogel opacificadas. RESULTADOS: A opacificação das lentes intra-oculares de hidrogel causou perdas de linhas de visão em 13 olhos (86,7%. A troca das lentes intra-oculares opacificadas promoveu o ganho de linhas de visão em 11 olhos (73,3%. As complicações peroperatórias ocorreram em três olhos (20% e foram as seguintes: perda de óleo de silicone, ruptura total de zônula com perda do saco capsular e ruptura parcial de zônula. Durante a explantação das lentes intra-oculares foi necessária a realização de incisões relaxantes na borda da capsulorrexe anterior em três olhos (20% e em dois olhos (13,3% os hápticos foram cortados sendo retirada somente a zona óptica das lentes intra-oculares. CONCLUSÃO: A cirurgia para explantação e substituição das lentes intra-oculares opacificadas mostrou-se eficaz naqueles pacientes com perdas de linhas de visão (p > 0,05.

  1. Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

    Directory of Open Access Journals (Sweden)

    Kamiya Kazutaka

    2012-04-01

    Full Text Available Abstract Introduction We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation A 53-year-old woman had undergone toric implantable collamer lens implantation three years earlier. After informed consent was obtained, we performed simultaneous toric implantable collamer lens removal and phacoemulsification with toric intraocular lens implantation. Preoperatively, the manifest refraction was 0, -0.5 × 15, with an uncorrected visual acuity of 0.7 and a best spectacle-corrected visual acuity of 0.8. Postoperatively, the manifest refraction was improved to 0, -0.5 × 180, with an uncorrected visual acuity of 1.2 and a best spectacle-corrected visual acuity of 1.5. No vision-threatening complications were observed. Conclusion Toric intraocular lens implantation may be a good surgical option for the correction of spherical and cylindrical errors in eyes with implantable collamer lens-induced cataract and astigmatism.

  2. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  3. Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy.

    Science.gov (United States)

    Gao, Shasha; Qin, Tingyu; Wang, Shengnan; Lu, Yong

    2015-01-01

    Background. To evaluate the clinical efficacy of suture fixation of foldable intraocular lens (IOL) in ciliary sulcus guided by ultrasound biomicroscopy (UBM). Methods. Thirty-five eyes of 32 cases needing suture fixation of foldable IOL in ciliary sulcus in our hospital were collected and divided into two groups: group A and group B. In group A, UBM was performed on 19 eyes of 17 cases before surgery to locate the projection position of ciliary sulcus in iris surface. In group B, the traditional sulcus fixation of IOL was performed on 16 eyes of 15 cases. The inserting position of needles, the haptics position of IOL and the IOL tilt, and decentration were observed by UBM examination 3 months after the surgery. Meanwhile, the vision and contrast sensitivity were analysed. Results. The differences in inserting position of the needle, the IOL tilt and decentration, the ratio of IOL haptics in sulcus, and uncorrected visual acuity were statistically significant (P 0.05). Conclusions. Sulcus fixation of foldable IOL aided by UBM can increase the accuracy of IOL haptics implanted into ciliary sulcus and reduce the IOL tilt and decentration.

  4. Aerobic exercise and intraocular pressure in normotensive and glaucoma patients

    Directory of Open Access Journals (Sweden)

    Chatzibalis Theodosios

    2009-08-01

    Full Text Available Abstract Background With the increasing number of people participating in physical aerobic exercise, jogging in particular, we considered that it would be worth knowing if there are should be limits to the exercise with regard to the intraocular pressure (IOP of the eyes. The purpose of this study is to check IOP in healthy and primary glaucoma patients after aerobic exercise. Methods 145 individuals were subdivided into seven groups: normotensives who exercised regularly (Group A; normotensives in whose right eye (RE timolol maleate 0.5% (Group B, latanoprost 0.005% (Group C, or brimonidine tartrate 0.2% (Group D was instilled; and primary glaucoma patients under monotherapy with β-blockers (Group E, prostaglandin analogues (Group F or combined antiglaucoma treatment (Group G instilled in both eyes. The IOP of both eyes was measured before and after exercise. Results A statistically significant decrease was found in IOP during jogging. The aerobic exercise reduces the IOP in those eyes where a b-blocker, a prostaglandin analogue or an α-agonist was previously instilled. The IOP is also decreased in glaucoma patients who are already under antiglaucoma treatment. Conclusion There is no ocular restriction for simple glaucoma patients in performing aerobic physical activity.

  5. Stem Cells in the Trabecular Meshwork for Regulating Intraocular Pressure.

    Science.gov (United States)

    Yun, Hongmin; Zhou, Yi; Wills, Andrew; Du, Yiqin

    2016-06-01

    Intraocular pressure (IOP) is still the main treatment target for glaucoma. Outflow resistance mainly exists at the trabecular meshwork (TM) outflow pathway, which is responsible for IOP regulation. Changes of TM cellularity and TM extracellular matrix turnover may play important roles in IOP regulation. In this article, we review basic anatomy and physiology of the outflow pathway and TM stem cell characteristics regarding the location, isolation, identification and function. TM stem cells are localized at the insert region of the TM and are label-retaining in vivo. They can be isolated by side-population cell sorting, cloning culture, or sphere culture. TM stem cells are multipotent with the ability to home to the TM region and differentiate into TM cells in vivo. Other stem cell types, such as adipose-derived stem cells, mesenchymal stem cells and induced pluripotent stem cells have been discovered for TM cell differentiation and TM regeneration. We also review glaucomatous animal models, which are suitable to study stem cell-based therapies for TM regeneration. PMID:27183473

  6. Effect of four different intraocular lenses on posterior capsule opacification

    Institute of Scientific and Technical Information of China (English)

    Rahmi; Duman; Fatih; Karel; Pelin; ?zyol; Can; Ates

    2015-01-01

    AIM: To evaluate the impact of 4 different intraocular lenses(IOLs) on posterior capsule opacification(PCO) by comparing the neodymium: yttrium-aluminum-garnet(Nd:YAG) laser capsulotomy rates.METHODS: This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one clinic. Four different IOLs were assessed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies.· RESULTS: An Nd:YAG laser posterior capsulotomy was performed in 153(3.07%) of the 4970 eyes. The mean follow-up time was 84 mo for all of the IOL groups. The percentage of eyes developing PCO was significantly greater for the acrylic hydrophilic IOLs than for the hydrophobic IOLs, although eyes with acrylic hydrophilic IOLs did not require Nd:YAG laser capsulotomy as soon as eyes with acrylic hydrophobic IOLs. There was no difference between the long-term PCO rates when 1-and 3-piece acrylic hydrophobic IOLs were compared or when IOLs made of the same material but with different haptic angles were compared.· CONCLUSION: In this study, eyes with acrylic hydrophilic IOLs were more likely to develop PCO than those with acrylic hydrophobic IOLs. The lens design(1-piece versus 3-piece and varying haptic angles) did not affect the PCO rate.

  7. Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy

    Directory of Open Access Journals (Sweden)

    Shasha Gao

    2015-01-01

    Full Text Available Background. To evaluate the clinical efficacy of suture fixation of foldable intraocular lens (IOL in ciliary sulcus guided by ultrasound biomicroscopy (UBM. Methods. Thirty-five eyes of 32 cases needing suture fixation of foldable IOL in ciliary sulcus in our hospital were collected and divided into two groups: group A and group B. In group A, UBM was performed on 19 eyes of 17 cases before surgery to locate the projection position of ciliary sulcus in iris surface. In group B, the traditional sulcus fixation of IOL was performed on 16 eyes of 15 cases. The inserting position of needles, the haptics position of IOL and the IOL tilt, and decentration were observed by UBM examination 3 months after the surgery. Meanwhile, the vision and contrast sensitivity were analysed. Results. The differences in inserting position of the needle, the IOL tilt and decentration, the ratio of IOL haptics in sulcus, and uncorrected visual acuity were statistically significant (P0.05. Conclusions. Sulcus fixation of foldable IOL aided by UBM can increase the accuracy of IOL haptics implanted into ciliary sulcus and reduce the IOL tilt and decentration.

  8. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Oriel Spierer

    2016-05-01

    Full Text Available A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  9. Reverse Optic Capture to Stabilize a Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Howard V. Gimbel

    2013-09-01

    Full Text Available Purpose: To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL. Method: Case report and literature review. Results: Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC are described. This patient presented with early, more than 70° off-axis rotation. The IOL was repositioned but was very mobile within the bag and tended to rotate off-axis; hence, it was stabilized in the desired position by capturing the optic through the anterior continuous curvilinear capsulorhexis, leaving the haptics in the bag. The immediate and 2-year postoperative follow-up revealed a stable and on-axis IOL with no visual, refractive or ocular complications. Conclusions: ROC is a useful and safe technique to address the problem of toric IOLs that tend to rotate at the time of surgery or are not stable postoperatively.

  10. Soft wearable contact lens sensor for continuous intraocular pressure monitoring.

    Science.gov (United States)

    Chen, Guo-Zhen; Chan, Ion-Seng; Leung, Leo K K; Lam, David C C

    2014-09-01

    Intraocular pressure (IOP) is a primary indicator of glaucoma, but measurements from a single visit to the clinic miss the peak IOP that may occur at night during sleep. A soft chipless contact lens sensor that allows the IOP to be monitored throughout the day and at night is developed in this study. A resonance circuit composed of a thin film capacitor coupled with a sensing coil that can sense corneal curvature deformation is designed, fabricated and embedded into a soft contact lens. The resonance frequency of the sensor is designed to vary with the lens curvature as it changes with the IOP. The frequency responses and the ability of the sensor to track IOP cycles were tested using a silicone rubber model eye. The results showed that the sensor has excellent linearity with a frequency response of ∼8 kHz/mmHg, and the sensor can accurately track fluctuating IOP. These results showed that the chipless contact lens sensor can potentially be used to monitor IOP to improve diagnosis accuracy and treatment of glaucoma.

  11. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful. PMID:27462251

  12. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens.

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  13. Surgical management of astigmatism with toric intraocular lenses

    Directory of Open Access Journals (Sweden)

    Bruna V. Ventura

    2014-04-01

    Full Text Available Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for choosing the correct toric IOL power and for planning optimal alignment. When calculating the power of toric IOLs, it is important to consider anterior and posterior corneal astigmatism, along with the surgically induced astigmatism. Accurate toric lens alignment along the calculated meridian is also crucial to achieve effective astigmatism correction. There are several techniques to guide IOL alignment, including the traditional manual marking technique and automated systems based on anatomic and topographic landmarks. The aim of this review is to provide an overview on astigmatism management with toric IOLs, including relevant patient selection criteria, corneal astigmatism measurement, toric IOL power calculation, toric IOL alignment, clinical outcomes and complications.

  14. Surface modification of intraocular lenses to reduce corneal endothelial damage.

    Science.gov (United States)

    Knight, P M; Link, W J

    1979-04-01

    Two methods of surface modification of PMMA, permanent and temporary, were investigated for use on intraocular lenses to reduce corneal endothelial damage due to corneal-IOL touch. Monomer grafting using gamma irradiation was found to produce permanently hydrophilic surfaces. Temporary surface modifications developed and tested were peelable and dissolvable coatings. Test samples were touched to freshly excised rabbit corneas to evaluate the effectiveness of the various surface modifications in reducing endothelial cell damage. This touch testing was performed using static testing in which the test sample was touched to the cornea without movement and dynamic testing in which there was relative movement between the cornea and the test sample. While unmodified PMMA did significant cell damage in both static and dynamic tests perpamently modified (hydrophilic grafted) surfaces were found to perform well in the static, but not in the dynamic tests. Dissolvable coatings performed well in both tests, even with very thin coatings. There was little differentiation between the various water-soluble coatings tested. Due to its characteristics and rate of dissolution, polyvinyl alcohol appears to be an optimum material for coating IOLs. A series of in vitro and in vivo tests performed to assess its safety indicate that PVA is nontoxic and safe in animal eyes. PMID:479004

  15. Measurement of Intraocular Pressure after LASIK by Dynamic Contour Tonometry

    Institute of Scientific and Technical Information of China (English)

    LIU Lei; LEI Cheng; LI Xinyu; Dong Jieyu

    2006-01-01

    Changes of corneal properties induced by laser in situ keratomileusis (LASIK) results in low inaccurate intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT).Before and after LASIK, the applied value of IOP, measured by dynamic contour tonometry (DCT)in comparison to GAT, was evaluated. Before and 1, 4 weeks after LASIK, the IOP in 30 cases (60 eyes) was measured by GAT and DCT respectively. The obtained results were statistically processed by SPSS11. 5 statistical software. The results showed that central corneal thickness (CCT)could affect GAT measurements but not DCT measurements. The comparison of IOP one and 4 weeks after LASIK revealed that the readings from GAT was separately decreased by 5.00±1.12 and 5.45±1. 13 mmHg as compared with those before LASIK, while those from DCT had no significant difference. It was concluded that LASIK-induced changes of CCT could influence the accuracy of GAT measurements, but had no influence on those from DCT. DCT was more beneficial to the measurements of IOP in normal eyes and those subject to LASIK surgery.

  16. Hypobaric Hypoxia: Effects on Intraocular Pressure and Corneal Thickness

    Directory of Open Access Journals (Sweden)

    Marcella Nebbioso

    2014-01-01

    Full Text Available Objective. The purpose of this study focused on understanding the mechanisms underlying ocular hydrodynamics and the changes which occur in the eyes of subjects exposed to hypobaric hypoxia (HH to permit the achievement of more detailed knowledge in glaucomatous disease. Methods. Twenty male subjects, aged 32±5 years, attending the Italian Air Force, were enrolled for this study. The research derived from hypobaric chamber, using helmet and mask supplied to jet pilotes connected to oxygen cylinder and equipped with a preset automatic mixer. Results. The baseline values of intraocular pressure (IOP, recorded at T1, showed a mean of 16±2.23 mmHg, while climbing up to 18,000 feet the mean value was 13.7±4.17 mmHg, recorded at T2. The last assessment was performed returning to sea level (T4 where the mean IOP value was 12.8±2.57 mmHg, with a significant change (P<0.05 compared to T1. Pachymetry values related to corneal thickness in conditions of hypobarism revealed a statistically significant increase (P<0.05. Conclusions. The data collected in this research seem to confirm the increasing outflow of aqueous humor (AH in the trabecular meshwork (TM under conditions of HH.

  17. Macroglobulinemia de Waldenström com hemorragia intra-ocular Waldenström's macroglobulinaemia with intraocular hemorrhage

    Directory of Open Access Journals (Sweden)

    João J. Nassaralla Júnior

    2006-12-01

    Full Text Available O objetivo deste trabalho é relatar um caso de macroglobulinemia de Waldenström com envolvimento retiniano e da circulação coroidiana, com boa resposta ao tratamento. O desenho é um caso controle intervencional. Um homem de 47 anos foi encaminhado para o serviço de hematologia para avaliação de anemia e linfadenopatia inguinal. O diagnóstico de macroglobulinemia de Waldenström foi feito com base nos achados clínicos e laboratoriais. O paciente desenvolveu hemorragia intra-ocular sem associação com hipertensão e com fatores de coagulação normais. Exame fundoscópico revelou retardamento na circulação coriorretiniana, microaneurismas, e telangiectasias no pólo posterior. Angiografia fluorescente demonstrou o prolongamento do tempo da circulação coroidiana, tempo de trânsito arteriovenoso também prolongado, e áreas de não perfusão capilar. Estes resultados foram acompanhados por uma elevação acentuada da IgM. A maioria dos achados oculares foi revertida com a plasmaférese. A macroglobulinemia de Waldenström pode envolver a retina e a circulação coroidiana, porém pode ser reversível com o tratamento apropriado.The aim of this work is to report a case of Waldenström's Macroglobulinaemia involving both retinal and choroidal circulation that resolved after treatment. The design is an interventional case report. A 47-year old male was admitted for evaluation of anaemia, and groin lymphadenopathy. A diagnosis of Waldenström's macroglobulinaemia was made based on clinical and laboratory findings. The patient developed intraocular hemorrhage without associated hypertension and with normal coagulation profile. A funduscopic examination revealed marked dilation and beading of the venous system, microaneurysms, and telangiectatic capillary beds in the posterior pole. A fluorescein angiography showed delayed choroidal filling, prolonged arteriovenous transit time and areas of capillary non-perfusion. These findings were

  18. Clinical Analysis of Early and Mid-late Elevated Intraocular Pressure after Silicone Oil Injection

    Institute of Scientific and Technical Information of China (English)

    Lifei Wang; Jingjiang Liu; Tianxiang Lu

    2014-01-01

    Purpose:To discuss the incidence and clinical features of early and mid-late elevated intraocular pressure after pars plana vitrectomy and silicone oil injection, and to evaluate the clinical management of eyes with secondary glaucoma. Methods:.This was an observational consecutive case series of 691 eyes in 679 patients who were treated with pars plana vitrectomy and silicone injection...The diagnostic criteria of early elevated intraocular pressure after silicone oil injection was ≥21 mmHg two weeks after surgery, while mid-late ele-vated intraocular pressure was ≥21 mmHg after two weeks. The incidence and clinical management of elevated intraocular pressure were analyzed. Results: In total, 211 of 691 eyes (30.54%) developed ele-vated intraocular pressure two weeks after pars plana vitrecto my and silicone injection. Of the 211 eyes, 101 eyes (47.87%) had ocular inflammation, 64 eyes (30.33%) showed hyphema, 35 eyes(16.59%) had silicone oil in the anterior chamber, 6 eyes. (2.84% ).had excess silicone oil injected,.and 5 eyes (2.37%).had rubeosis irides. Eighty three of 691 eyes (12.01%). developed elevated intraocular pressure after two weeks..Of these 83 eyes, 25 eyes (30.12%) had rubeosis irides,.16 eyes (19.27%) had issues related to topic steroid therapy,.13 eyes . (15.66%).had a papillary block,.silicone oil in the anterior chamber,10 eyes (12.05%) had a silicone emulsion,.10 eyes (12.05% ).had peripheral anterior synchiae,.and 9 eyes (10.84%).had silicone oil in the anterior chamber..All eyes with elevated intraocular pressure were treated with antiglau-coma medications and surgeries. Conclusion:.The reasons for elevated intraocular pressure dif-fered between early and mid-late after pars plana vitrectomy and silicone oil injection. The elevated intraocular pressure can be controlled effectively by immediate diagnosis and proper treatment with medicine and operation.

  19. Electrochemical lysis at the stage of endoresection for large posterior intraocular tumors

    Directory of Open Access Journals (Sweden)

    Yu. A. Belyy

    2012-01-01

    Full Text Available Purpose: to design the new combined technique of endoresection with intraoperative intraocular electrochemical lysis at the tumor destruction stage for large posterior intraocular tumors.Methods: 3 patients (3 eyes with large choroidal melanomas t3N0M0 (tumor thickness — 8-10 mm, base diameter — 13-15 mm, juxtapapillary localization. Mean age was 55.4 years old. Endoresection with intraoperational intraocular electrochemical lysis of the tumor was performed. Electrochemical lysis was performed with use of the technical unit ECU 300 (Soering, Germany and the original method of combined intratumoral positioning of two platinum electrodes: anode and cathode.Results: the tumor was removal completely in all 3 cases. the anatomical retinal reattachment was reached in all patients. Sclera was safe in all 3 cases. Visual acuity was not changed (NLP. At the place of the removal tumor a surgical choroidal coloboma without pigmentation all over scleral bed and periphery was shown in all cases in distant postoperative period (from 1.5 to 3 years. No local recurrences or metastasis were revealed in all patients.Conclusion: Further investigations in clinical group are necessarily to determinate the real possibilities of the combined method and the indications for endoresection with intraoperative intraocular electrochemical lysis for large intraocular tumors. 

  20. Intraocular lens implantation for the treatment of astigmatism%人工晶状体植入术矫正散光

    Institute of Scientific and Technical Information of China (English)

    施俊廷; 徐雯

    2013-01-01

    Refractive intraocular lens surgery can be used for the treatment of moderate and high regular astigmatism.Refractive intraocular lens surgery includes aphakic intraocular lens surgery and phakic intraocular lens surgery.In phakic intraocular lens surgery two types of intraocular lenses are used:iris-claw intraocular lens and posterior chamber intraocular lens.The purpose of this article is to review current knowledge of surgical treatments of astigmatism with a particular focus on toric implantable collamer lenses.%人工晶状体(IOL)植入术能矫正中、高度规则散光.矫正散光的IOL植入术可分为无晶状体眼及有晶状体眼的环曲面IOL植入两类,其中有晶状体眼的环曲面IOL又可分为虹膜夹持型及后房型.本文旨在介绍IOL矫正散光的手术治疗方法,并着重介绍有晶状体眼植入后房型IOL矫正屈光不正合并散光的治疗技术.

  1. Intraocular lens power calculation in eyes with short axial length

    Directory of Open Access Journals (Sweden)

    Marilita M Moschos

    2014-01-01

    Full Text Available Aim: To evaluate and compare the predictive capacity of four intraocular lens (IOL power calculation formulas (SRK/T, Hoffer Q, Holladay 1, and Haigis in eyes shorter than 22.0 mm. Setting and Design: Observational study. Materials and Methods: Participants in our study were 69 consecutive patients with a preoperative axial length (AL of less than 22.0 mm in one or both eyes. All patients underwent phacoemulsification with IOL implantation and postoperative target of refraction was analyzed. Specifically, the differences in the mean absolute estimation error (AE for the four formulas were analyzed. Furthermore, the percentage of eyes with AE within ±0.5 and ±1.0 D for each formula was estimated, as well as the correlation coefficient (r between the AL and estimation error (E for each formula. The Mann-Whitney U test was used to compare differences in the AEs of the formulas. A statistically significant difference was defined as P < 0.05. Results: The Haigis formula had statistically significant smaller mean AE in comparison to Holladay 1, Hoffer Q, and SRK/T. The Haigis formula predicted more eyes with E within ±0.5 and ±1.0 D of predicted spherical equivalent compared to other formulas. Correlation between AL and AE revealed a negative r value and P < 0.05 for all formulas. Conclusions: Haigis formula provides more accurate results concerning the postoperative target of refraction in eyes with AL less than 22.0 mm. Hoffer Q could be also used as an alternative.

  2. Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses

    Science.gov (United States)

    Brezna, Wolfgang; Lux, Kirsten; Dragostinoff, Nikolaus; Krutzler, Christian; Plank, Nicole; Tobisch, Rainer; Boltz, Agnes; Garhöfer, Gerhard; Told, Reinhard; Witkowska, Katarzyna; Schmetterer, Leopold

    2016-01-01

    Purpose The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses. Methods The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjects aged between 18 and 35 years. Visual acuity (Early Treatment Diabetic Retinopathy Study; ETDRS) and contrast sensitivity tests (Pelli-Robson) under different lighting conditions (luminosities from 0.14–55 cd/m2, mesopic to photopic) were performed at different distances. Results Visual acuity tests showed no difference for corrected distance visual acuity data of bi- and trifocal lens prototypes (P = 0.851), but better results for the trifocal than for the bifocal lenses at distance corrected intermediate (P = 0.021) and distance corrected near visual acuity (P = 0.044). Contrast sensitivity showed no differences between bifocal and trifocal lenses at the distant (P = 0.984) and at the near position (P = 0.925), but better results for the trifocal lens at the intermediate position (P = 0.043). Visual acuity and contrast sensitivity showed a strong dependence on luminosity (P < 0.001). Conclusions At all investigated distances and all lighting conditions, the trifocal lens prototype often performed better, but never worse than the bifocal lens prototype. Translational Relevance The vision simulator can fill the gap between preclinical lens development and implantation studies by providing information of the perceived vision quality after cataract surgery without implantation. This can reduce implantation risks and promotes the development of new lens concepts due to the cost effective test procedure. PMID:27777828

  3. Computerized invasive measurement of time-dependent intraocular pressure

    Directory of Open Access Journals (Sweden)

    T.V.O. Campos

    2006-09-01

    Full Text Available Several methods have been described to measure intraocular pressure (IOP in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.

  4. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  5. Driving time modulates accommodative response and intraocular pressure.

    Science.gov (United States)

    Vera, Jesús; Diaz-Piedra, Carolina; Jiménez, Raimundo; Morales, José M; Catena, Andrés; Cardenas, David; Di Stasi, Leandro L

    2016-10-01

    Driving is a task mainly reliant on the visual system. Most of the time, while driving, our eyes are constantly focusing and refocusing between the road and the dashboard or near and far traffic. Thus, prolonged driving time should produce visual fatigue. Here, for the first time, we investigated the effects of driving time, a common inducer of driver fatigue, on two ocular parameters: the accommodative response (AR) and the intraocular pressure (IOP). A pre/post-test design has been used to assess the impact of driving time on both indices. Twelve participants (out of 17 recruited) completed the study (5 women, 24.42±2.84years old). The participants were healthy and active drivers with no visual impairment or pathology. They drove for 2h in a virtual driving environment. We assessed AR and IOP before and after the driving session, and also collected subjective measures of arousal and fatigue. We found that IOP and AR decreased (i.e., the accommodative lag increased) after the driving session (p=0.03 and p<0.001, respectively). Moreover, the nearest distances tested (20cm, 25cm, and 33cm) induced the highest decreases in AR (corrected p-values<0.05). Consistent with these findings, the subjective levels of arousal decreased and levels of fatigue increased after the driving session (all p-values<0.001). These results represent an innovative step towards an objective, valid, and reliable assessment of fatigue-impaired driving based on visual fatigue signs. PMID:27235337

  6. Early clinical outcome with a new monofocal microincision intraocular lens.

    Science.gov (United States)

    Toygar, Baha; Yabas Kiziloglu, Ozge; Toygar, Okan; Hacimustafaoglu, Ali Murat

    2016-10-01

    The purpose of this study was to evaluate the early visual and refractive outcomes of a new aspheric monofocal microincision intraocular lens (IOL). This retrospective case series included eyes of patients who underwent implantation of a microincision IOL following 1.8 mm manual coaxial microincision cataract surgery and who attended regular postoperative follow-up visits on the first week and first, third, and sixth months. The postoperative uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), refraction and predictability, intraoperative and postoperative complications, posterior capsule opacification (PCO), IOL centration, and surgically induced astigmatism (SIA) were evaluated. Sixty-three eyes of 38 patients ranging in age from 51 to 86 were included in the study. The mean preoperative BCVA was 0.52 ± 0.42 logMAR. At the postoperative sixth month, the mean postoperative UCVA and BCVA were 0.12 ± 0.11 and 0.01 ± 0.03 logMAR, respectively. The mean postoperative spherical equivalent refraction (SER) was -0.30 ± 0.49 D. The SER was within ± 1.00 D of the attempted correction in 95.2 % of the eyes. The mean SIA measured with vector analysis was 0.45 ± 0.28 D. Mild PCO was observed in 9 eyes (14.7 %) with none requiring Nd:Yag laser capsulotomy. On centration analysis, the IOL was found to be 0.26 mm on average to the supero-nasal position. The aspheric microincision IOL was safely implanted and provided satisfactory visual and refractive outcomes in the early postoperative period.

  7. Retreatments after multifocal intraocular lens implantation: an analysis

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Makari, Sarah; Ostenstad, Steffen; Potvin, Rick

    2016-01-01

    Purpose To determine the incidence and etiology of required retreatment after multifocal intraocular lens (IOL) implantation and to evaluate the methods and clinical outcomes of retreatment. Patients and methods A retrospective chart review of 416 eyes of 209 patients from one site that underwent uncomplicated cataract surgery with multifocal IOL implantation. Biometry, the IOL, and refractive data were recorded after the original implantation, with the same data recorded after retreatment. Comments related to vision were obtained both before and after retreatment for retreated patients. Results The multifocal retreatment rate was 10.8% (45/416 eyes). The eyes that required retreatment had significantly higher residual refractive astigmatism compared with those who did not require retreatment (1.21±0.51 D vs 0.51±0.39 D, P<0.01). The retreatment rate for the two most commonly implanted primary IOLs, blended bifocal (10.5%, 16/152) and bilateral trifocal (6.9%, 14/202) IOLs, was not statistically significantly different (P=0.12). In those requiring retreatment, refractive-related complaints were most common. Retreatment with refractive corneal surgery, in 11% of the eyes, and piggyback IOLs, in 89% of the eyes, was similarly successful, improving patient complaints 78% of the time. Conclusion Complaints related to ametropia were the main reasons for retreatment. Residual astigmatism appears to be an important determinant of retreatment rate after multifocal IOL implantation. Retreatment can improve symptoms for a high percentage of patients; a piggyback IOL is a viable retreatment option. PMID:27041983

  8. Energy Efficiency of a New Trifocal Intraocular Lens

    Science.gov (United States)

    Vega, F.; Alba-Bueno, F.; Millán, M. S.

    2014-01-01

    The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.

  9. Intraocular lens exchange for high myopia in pseudophakic children.

    Science.gov (United States)

    Kraus, C L; Trivedi, R H; Wilson, M E

    2016-09-01

    PurposeThe purpose of this study was to examine the preoperative factors and postoperative outcomes following intraocular lens (IOL) exchange for high myopia in pseudophakic children.MethodsThe medical records of all patients undergoing IOL exchange for high myopia were retrospectively reviewed.ResultsA total of 15 eyes were identified that had undergone an IOL exchange for myopic shift. Average age of cataract extraction (CE) was 5.4 months. In all, 10/15 had a unilateral cataract. IOL exchange usually occurred at an average of 6 years following cataract surgery. The average spherical equivalent (SE) of the refractive error at that time was -9.6 D. Following IOL exchange, SE was -1.3 D. A two-line reduction in best-corrected visual acuity was observed in 1/13 of our patients for whom pre- and post-exchange data were available. The average axial length (AL) of the eye undergoing the IOL exchange was 24.0 mm, average AL in the non-operative eye was 22.1 mm. On average, the operative eyes grew 4.4 mm and the non-operative eyes 3.02 mm. No adverse events were seen in the operative eyes.ConclusionYounger age at the time of CE creates a greater likelihood of AL elongation and predisposes a child to myopic shift. IOL exchange should be considered an option to reduce anisometropia and associated aniseikonia to improve visual outcomes. Successful visual rehabilitation and predictable post-exchange refractions were seen with our patients.

  10. Modified Scleral Flap Incision to Reduce Corneal Astigmatisn after Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    YizhiLiu; ShaozhenLi

    1995-01-01

    Purpose:To investigate a simple method during extracapsular cataract extraction with posteior chamber intraocular lens implantation in order to reduce surgically induced corneal astig-matism.Methods:A modified scleral flap incision was used in the extracapsular cataract extraction with intraocular lens implantation and the postoperative changes in conreal astigmatism was observed.Results:The peak value of postoperative corneal astigmatism was3.60D,and the corneal astigmatism regression was 2.11D,surgically induced astigmatism was less significant in modified scleral flap incision group than that in convention-al limbal incison group(P<0.05).Conclusions:The modified scleral flap inciston is an ideal incision for cataract ex-traction with intraocular lens implantation when phacoemulsifier is not avaliable.Eye Science1995;11:136-139.

  11. Laser-triggered intraocular implant to induce photodynamic therapy for posterior capsule opacification prevention.

    Science.gov (United States)

    Zhang, Zhaoguo; Huang, Wenyong; Lei, Ming; He, Yuanfeng; Yan, Mina; Zhang, Xuefei; Zhao, Chunshun

    2016-02-10

    Posterior capsule opacification (PCO) is one of the main reasons for loss of vision again after cataract surgery. In this study, intraocular lenses were modified with indocyanine green (ICG) and sealed up with PLGA to form long-term intraocular implants (ICG-IOL). When triggered by laser, ICG-IOL would induce photodynamic therapy (PDT). In-vitro cell viability assay and scratch wound healing assay demonstrated that ICG-IOL could effectively inhibit HLEpiC proliferation and migration without causing damage to the cells far away from it. Laser attenuation test indicated that ICG-IOL could be applied in vivo. In-vivo pharmacodynamics and safety study showed that ICG-IOL could significantly prevent the occurrence of PCO and was safe for intraocular normal tissue. All these results suggested that ICG-IOL would be a very promising candidate for PCO prevention.

  12. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Wei Ching-Kuo

    2012-10-01

    Full Text Available Abstract Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  13. Role of interferon-γ and cytotoxic T lymphocytes in intraocular tumor rejection.

    Science.gov (United States)

    Ligocki, Ann J; Brown, Joseph R; Niederkorn, Jerry Y

    2016-05-01

    The eye is normally an immunosuppressive environment. This condition is better known as immune privilege and protects the eye from immune-mediated inflammation of tissues that cannot regenerate. However, immune privilege creates a dilemma for the eye when intraocular neoplasms arise. In some cases, immune privilege is suspended, resulting in the immune rejection of intraocular tumors. This study employed a mouse model in which interferon-γ-dependent intraocular tumor rejection occurs. We tested the hypothesis that this rejection requires interferon-γ for the generation and functional capacity of cytotoxic T lymphocyte-mediated rejection of intraocular tumors. Tumors grew progressively in the eyes of interferon-γ knockout mice, even though the mice generated tumor-specific cytotoxic T lymphocyte responses in the periphery. However, interferon-γ knockout mice rejected tumors that were introduced into extraocular sites. Subcutaneous tumor immunization before intraocular challenge led to tumor rejection and preservation of the eye in wild-type mice. By contrast, tumors grew progressively in the eyes of interferon-γ knockout mice despite their ability to generate peripheral tumor-specific cytotoxic T lymphocytes as well as the capacity of CD8(+) T cells to enter the eye as shown by the presence of CD8 and perforin message and CD3(+)CD8(+) leukocytes within the tumor-bearing eye. We found that cytotoxic T lymphocytes generated in wild-type mice and adoptively transferred into interferon-γ knockout mice mediated the rejection of intraocular tumors in interferon-γ knockout hosts. The results indicate that interferon-γ is critical for the initial priming and differentiation of cytotoxic T lymphocytes residing in the periphery to produce the most effect antitumor function within the eye.

  14. Immediate retinal adhesion by CO2 laser irradiation using a fiberoptic intraocular probe.

    Science.gov (United States)

    DeRowe, A; Bartov, E; Treister, G; Belkin, M; Katzir, A

    1992-01-01

    Using an experimental fiberoptically guided CO2 laser system, we produced lesions on fresh bovine retinas. These lesions were shown to achieve immediate measurable chorioretinal adhesion. This model provides preliminary data on the use of a fiberoptic CO2 laser probe to produce chorioretinal lesions and possible future use in intraocular surgery for retinal detachment. The advantages of using CO2 laser energy are minimal damage surrounding desired lesion and its versatility as a coagulator and cutter. With modifications, CO2 endolaser may have a role in intraocular surgery. PMID:1453861

  15. Ophthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors

    Directory of Open Access Journals (Sweden)

    Matsuura K

    2014-01-01

    Full Text Available Kazuki Matsuura,1 Yoshitsugu Inoue2 1Nojima Hospital, 2Tottori University, Kurayoshi City, Tottori, Japan Background: The purpose of this study was to assess the risk of intraocular contamination caused by intraocular lens (IOL insertion with injectors by observing the dynamics of an ophthalmic viscosurgical device (OVD. Methods: Each type of injector was equipped with a colored OVD and IOL, and a 2 mm length from the tip of the cartridge was replaced with a colored OVD. The various combinations of IOLs and injectors used were: a three-piece shaped IOL, VA60BBR + TypeE1 (HOYA incision size 2.5 mm; group A, n=5; a single-piece IOL, 251+ iSert micro, preloaded (HOYA, incision size 2.2 mm; group G, n=5; and a single-piece IOL, SN6CWS preloaded (Alcon, incision size 2.7 mm; group C, n=5. Results: In group A, the intraocular OVD instantly flowed backward into the injector, whereas the colored OVD was pushed backward deep inside the cartridge without flowing into the eye. In group B, the backflow of the intraocular OVD into the injector was limited, resulting in the influx of a large amount of the colored OVD into the eye along with the IOL. In group C, as in group A, a large amount of the intraocular OVD flowed backward into the injector. Consequently, a small amount of the colored OVD flowed into the eye. Conclusion: The tip of the injector and OVD could be contaminated because the surgical field cannot be completely sterile, even after preoperative disinfection. Our experiments revealed that OVD backflow into the injector cavity occurs during IOL insertion, and this phenomenon may have minimized intraocular contamination. However, small-diameter cartridges along with plate-type haptics allow insufficient OVD backflow, resulting in intraocular influx of the contaminated OVD. Surgeons have to be notified that intraoperative bacterial contamination can occur even after IOL insertion using injectors. Keywords: intraocular lens insertion

  16. Intraocular/Intracranial pressure mismatch hypothesis for visual impairment syndrome in space.

    Science.gov (United States)

    Zhang, Li-Fan; Hargens, Alan R

    2014-01-01

    Visual impairment intracranial pressure syndrome (VIIP) is considered a major risk for future human spaceflight. Loss of hydrostatic pressure gradients in vascular and cerebrospinal fluid systems due to the removal of gravity associated with subsequent intracranial and intraocular fluid shifts and the resulting intraocular/intracranial pressure mismatch might be important etiology factors causingVIIP syndrome. Acclimation changes in the ocular and cerebral circulation and the two fluid systems during chronic microgravity exposure and their underlying mechanisms need further elucidation. Relevant findings may help to validate the pressure differential hypothesis for VlIP syndrome and to evaluate whether a gravity based countermeasure is needed. PMID:24479265

  17. Symbolic algebra approach to the calculation of intraocular lens power following cataract surgery

    Science.gov (United States)

    Hjelmstad, David P.; Sayegh, Samir I.

    2013-03-01

    We present a symbolic approach based on matrix methods that allows for the analysis and computation of intraocular lens power following cataract surgery. We extend the basic matrix approach corresponding to paraxial optics to include astigmatism and other aberrations. The symbolic approach allows for a refined analysis of the potential sources of errors ("refractive surprises"). We demonstrate the computation of lens powers including toric lenses that correct for both defocus (myopia, hyperopia) and astigmatism. A specific implementation in Mathematica allows an elegant and powerful method for the design and analysis of these intraocular lenses.

  18. Sensitivity of the corneal-plane refractive compensation to change in power and axial position of an intraocular lens

    Directory of Open Access Journals (Sweden)

    W. F. Harris

    2009-12-01

    Full Text Available If an intraocular lens is displaced or if its power is changed what are the consequences for the refractive compensation of the eye?  Gaussian optics is used to obtain explicit formulae for the sensitivityof the corneal-plane refractive compensation (also called the refraction, refractive state, etc to change in power and axial displacement of a thin intraocular lens implanted in a simple eye.  In particular, for a pseudophakic Gullstrand simplified eye with intraocular lens placed 5 mm behind the cornea the sensitivity to errors in the power of the intraocular lens is about  71 . 0 − 71 for an intraocular lens of power   for an intraocular lens of power 20 D, that is, the refractive compensation decreases by about 0.71 dioptres per dioptre increase in the power of the intraocular lens.  More generally the sensitivity is approximately  ( m   0037 . 0 63 . 0 F − − 0.63 ( 003 . 0 63 . 0 − − (0.0037mF where FI is the power of the intraocular lens.  Also for Gullstrand’s simplified eye the sensitivity of refractive compensation to axial displacement of the intraocular lens is approximately linear in FI about  (64D FI, in fact.  That is, for each dioptre of the power of the intraocular lens the refractive compensation increases by about 0.064 dioptres per millimetre of axial displacement towards the retina. 

  19. Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Potvin, Rick

    2016-01-01

    Purpose The aim of this study was to compare a new diffractive trifocal toric lens with an apodized diffractive bifocal toric lens in terms of refractive and visual acuity (VA) outcomes, including low-contrast VA (LCVA), as well as the patient’s visual function 3 months after implantation. Patients and methods This is a randomized prospective study involving bilateral implantation of a trifocal toric or a bifocal toric lens. At 3 months postoperatively, the subject’s vision was tested both uncorrected and with his/her best distance correction at: distance (4 m), intermediate (63 cm), and near (40 cm). Binocular defocus curves were measured with no correction and with the subject’s best distance correction in place. Quality of vision was measured using the National Eye Institute Visual Function Questionnaire. Results A total of 22 patients were enrolled (eleven in each group). There was no statistically significant difference in the absolute change in measured rotation between 1 month and 3 months postoperatively between the two intraocular lens (IOL) groups (P=0.98). At 3 months, the postoperative refraction and distance VA by eye were similar between groups. There was no statistically significant difference in the measured LCVA between groups (P=0.39). The defocus curve showed that at 67 cm, the trifocal toric lens had statistically significantly better VA when compared to the bifocal toric lens. There were no statistically significant differences by group for any of the National Eye Institute Visual Function Questionnaire scores (P>0.26 in all cases). Conclusion The trifocal toric IOL improved the intermediate vision without negatively impacting visual function and distance, near, or low-contrast VA when compared to a bifocal toric IOL. The toric component of the trifocal lens effectively reduced astigmatism and provided good rotational stability. PMID:27051269

  20. Drug loading of foldable commercial intraocular lenses using supercritical impregnation.

    Science.gov (United States)

    Bouledjouidja, A; Masmoudi, Y; Sergent, M; Trivedi, V; Meniai, A; Badens, E

    2016-03-16

    The drug delivery through intraocular lenses (IOLs) allows the combination of cataract surgery act and postoperative treatment in a single procedure. In order to prepare such systems, "clean" supercritical CO2 processes are studied for loading commercial IOLs with ophthalmic drugs. Ciprofloxacin (CIP, an antibiotic) and dexamethasone 21-phosphate disodium (DXP, an anti-inflammatory drug) were impregnated into foldable IOLs made from poly-2-hydroxyethyl methacrylate (P-HEMA). A first pre-treatment step was conducted in order to remove absorbed conditioning physiological solution. Supercritical impregnations were then performed by varying the experimental conditions. In order to obtain transparent IOLs and avoid the appearance of undesirable foaming, it was necessary to couple slow pressurization and depressurization phases during supercritical treatments. The impregnation yields were determined through drug release studies. For both drugs, release studies show deep and reproducible impregnation for different diopters. For the system P-HEMA/CIP, a series of impregnations was performed to delimit the experimental range at two pressures (80 and 200 bar) in the presence or absence of ethanol as a co-solvent for two diopters (+5.0 D and +21.0 D). Increase in pressure in the absence of a co-solvent resulted in improved CIP impregnation. The addition of ethanol (5 mol%) produced impregnation yields comparable to those obtained at 200 bar without co-solvent. A response surface methodology based on experimental designs was used to study the influence of operating conditions on impregnation of IOLs (+21.0 D) in the absence of co-solvent. Two input variables with 5 levels each were considered; the pressure (80-200 bar) and the impregnation duration (30-240 min). CIP impregnation yields ranging between 0.92 and 3.83 μg CIP/mg IOL were obtained from these experiments and response surface indicated the pressure as a key factor in the process. The DXP impregnation in P-HEMA was

  1. Toric intraocular lens orientation and residual refractive astigmatism: an analysis

    Directory of Open Access Journals (Sweden)

    Potvin R

    2016-09-01

    Full Text Available Rick Potvin,1 Brent A Kramer,2 David R Hardten,3 John P Berdahl4 1Science in Vision, Akron, NY, 2University of Iowa Carver College of Medicine, Iowa City, IA, 3Minnesota Eye Consultants, Minnetonka, MN, 4Vance Thompson Vision, Sioux Falls, SD, USA Purpose: To analyze intraocular lens (IOL orientation data from an online toric back-calculator (astigmatismfix.com for determining if differences were apparent by lens type.Methods: A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis.Results: Of 12,812 total validated calculation records, 8,229 included intended orientation and lens identification data. Of the latter, 5,674 calculations (69% involved lenses oriented 5° or more from their intended position. Using estimated toric lens usage data, the percentage of lenses with orientation ≥5° from intended was 0.89% overall, but the percentage varied significantly between specific toric lens brands (P<0.05. The percentage of back-calculations related to lenses that were not oriented as intended was also statistically significantly different by lens brand (P<0.05. When IOLs were misoriented, they were significantly more likely to be misoriented in a counterclockwise direction (P<0.05. This was found to be due to a bias toward counterclockwise orientation observed with one specific brand, a bias that was not observed with the other three brands analyzed here.Conclusion: The percentage of eyes with lens orientation ≥5° from intended in the Toric Results Analyzer data set was <1% of toric IOLs in general, with the relative percentage of Tecnis® Toric IOLs significantly higher than AcrySof® Toric IOLs. Both of these had higher rates than the Staar® Toric and Trulign® Toric lenses, with the availability of higher Tecnis and AcrySof cylinder powers a likely contributing factor. The AcrySof Toric IOL appears to be less likely than the Tecnis Toric IOL to cause residual

  2. Comparison of two optical biometers in intraocular lens power calculation

    Directory of Open Access Journals (Sweden)

    Sheng Hui

    2014-01-01

    Full Text Available Aims: To compare the consistency and accuracy in ocular biometric measurements and intraocular lens (IOL power calculations using the new optical low-coherence reflectometry and partial coherence interferometry. Subjects and Methods: The clinical data of 122 eyes of 72 cataract patients were analyzed retrospectively. All patients were measured with a new optical low-coherence reflectometry system, using the LENSTAR LS 900 (Haag Streit AG/ALLEGRO BioGraph biometer (Wavelight., AG, and partial coherence interferometry (IOLMaster V.5.4 [Carl Zeiss., Meditec, AG] before phacoemulsification and IOL implantation. Repeated measurements, as recommended by the manufacturers, were performed by the same examiner with both devices. Using the parameters of axial length (AL, corneal refractive power (K1 and K2, and anterior chamber depth (ACD, power calculations for AcrySof SA60AT IOL were compared between the two devices using five formulas. The target was emmetropia. Statistical analysis was performed using Statistical Package for the Social Sciences software (SPSS 13.0 with t-test as well as linear regression. A P value < 0.05 was considered to be statistically significant. Results: The mean age of 72 cataract patients was 64.6 years ± 13.4 [standard deviation]. Of the biometry parameters, K1, K2 and [K1 + K2]/2 values were significantly different between the two devices (mean difference, K1: −0.05 ± 0.21 D; K2: −0.12 ± 0.20 D; [K1 + K2]/2: −0.08 ± 0.14 D. P <0.05. There was no statistically significant difference in AL and ACD between the two devices. The correlations of AL, K1, K2, and ACD between the two devices were high. The mean differences in IOL power calculations using the five formulas were not statistically significant between the two devices. Conclusions: New optical low-coherence reflectometry provides measurements that correlate well to those of partial coherence interferometry, thus it is a precise device that can be used for the

  3. Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube.

    Directory of Open Access Journals (Sweden)

    Ghai B

    2001-07-01

    Full Text Available AIMS: To evaluate the intraocular pressure and haemodynamic changes subsequent to insertion of laryngeal mask airway and endotracheal tube. SUBJECTS AND METHODS: The study was conducted in 50 adult patients. A standard general anaesthesia was administered to all the patients. After 3 minutes of induction of anaesthesia baseline measurements of heart rate, non-invasive blood pressure and intraocular pressure were taken following which patients were divided into two groups: laryngeal mask airway was inserted in group 1 and tracheal tube in group 2. These measurements were repeated at 15-30 second, every minute thereafter up to 5 minutes after airway instrumentation. RESULTS: A statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure was seen in both the groups subsequent to insertion of laryngeal mask airway or endotracheal tube. Mean maximum increase was statistically more after endotracheal intubation than after laryngeal mask airway insertion. The duration of statistically significant pressure responses was also longer after endotracheal intubation. CONCLUSION: Laryngeal mask airway is an acceptable alternative technique for ocular surgeries, offering advantages in terms of intraocular pressure and cardiovascular stability compared to tracheal intubation.

  4. Comparison of a hydrophilic and a hydrophobic apodized diffractive multifocal intraocular lens.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2013-01-01

    To compare outcomes between a new design apodized diffractive hydrophilic multifocal intraocular lens (IOL) (Seelens MF; study group), and a well-known apodized diffractive hydrophobic multifocal IOL (SN6AD1; control group). A comparative case series comparing refractive and visual outcomes at dista

  5. Clinical comparison of the optical performance of aspheric and spherical intraocular lenses

    NARCIS (Netherlands)

    van Gaalen, Kim W.; Koopmans, Steven A.; Jansonius, Nomdo M.; Kooijman, Aart C.

    2010-01-01

    PURPOSE: To compare the optical performance of aspheric Tecnis ZA9003 and spherical Sensar AR40e intraocular lenses (IOLs). SETTING: Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. METHODS: An aspheric IOL was implan

  6. The case for intraocular delivery of PPAR agonists in the treatment of diabetic retinopathy.

    LENUS (Irish Health Repository)

    Treacy, Maxwell P

    2012-09-01

    Systemic therapeutics targeting the peroxisome proliferator-activated receptors have been found to be beneficial in the treatment of diabetic retinopathy. In this paper, we provide a rationale for the use of these therapeutics as intraocular agents. In addition, we introduce the peroxisome proliferator-activated receptors and describe their functions in response to the drugs.

  7. Comparison of ocular straylight after implantation of multifocal intraocular lenses

    NARCIS (Netherlands)

    Łabuz, Grzegorz; Reus, Nicolaas J; van den Berg, Thomas J T P

    2016-01-01

    UNLABELLED: A comprehensive review of the effect of multifocal intraocular lens (IOL) designs on postoperative ocular straylight was performed. Studies reporting straylight values obtained with the natural pupil using the C-Quant device after uneventful multifocal IOL implantation were included. The

  8. 23-gauge Transconjunctival Sutureless Vitrectomy in Eyes with Posteriorly Dislocated Intraocular Lens after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Fatih Horozo¤lu

    2011-08-01

    Full Text Available Purpose: To evaluate the outcomes of 23-gauge (23-G transconjunctival sutureless vitrectomy (TSV in eyes with posteriorly dislocated intraocular lens (IOL after cataract surgery. Material and Method: In this retrospective study, we evaluated 6 eyes of 6 consecutive cases with posteriorly dislocated intraocular lens after cataract surgery between April 2007 and November 2010. Visual acuity, intraocular pressure, detailed fundus examination and details of surgery were recorded. Results: The mean age of the patients was 64.7 years and the mean follow-up was 5.5 months (3-12 months. All eyes received 23-G TSV. Dislocated IOL was removed from the vitreous and implanted into ciliary sulcus in 2 eyes (33.3% with polymethylmetacrilate IOL and in 4 eyes (66.7% with 3-piece hydrophilic acrylic IOL. In 5 of the 6 eyes (83.7%, visual acuity improved postoperatively. In one eye (16.7%, elevation of intraocular pressure was observed postoperatively and controlled by topical treatment. Discussion: 23-G TSV surgery may be used in eyes with posteriorly IOLs after cataract surgery. Studies with a larger number of patients would better demonstrate the efficacy of this method. (Turk J Ophthalmol 2011; 41: 213-6

  9. X-ray diffraction enhanced imaging study of intraocular tumors in human beings

    International Nuclear Information System (INIS)

    Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of human eyeball in this work. The images of surgical specimens from malignant intraocular tumor of hospitalized patients were taken using the hard X-rays from the topography station of Beamline 4W1A at Beijing Synchrotron Radiation Facility (BSRF). The obtained radiographic images were analyzed in correlation with those of pathology. The results show that the anatomic and pathologic details of intraocular tumors in human beings can be observed clearly by DEI for the first time, with good visualization of the microscopic details of eyeball ring such as sclera, choroid and other details of intraocular organelles. And the best resolution of DEI images reaches up to the magnitude of several tens of μm. The results suggest that it is capable of exhibiting clearly the details of intraocular tumor using DEI method. (authors)

  10. Bilateral transient pupil closure after iris supported intraocular lens implantation in a case with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Necip Kara

    2012-01-01

    Full Text Available A 16-year-old woman presented with Marfan syndrome and bilateral ectopia lentis. The surgical treatment including removal of the crystalline lens and implantation of an iris-supported intraocular lens in both eyes at a week interval. Postoperatively, the biomicroscopic examination showed total pupil closure bilaterally. After the topical tropicamide treatment, the pupil returned to normal shape.

  11. Iris-fixated anterior chamber phakic intraocular lens for myopia moves posteriorly with mydriasis.

    NARCIS (Netherlands)

    Cruysberg, L.P.J.; Doors, M.; Berendschot, T.T.; Brabander, J. De; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    PURPOSE: To elucidate the physiological characteristics of eyes implanted with iris-fixated anterior chamber phakic intraocular lenses (pIOLs), which are increasingly being used for the correction of higher myopic and hyperopic refractive errors. METHODS: In a case series of 20 patients (39 eyes), t

  12. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Ugur Unsal

    2016-01-01

    Full Text Available Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p=0.50 and p=0.509, resp.. The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p=0.049, p=0.005, and p=0.001, resp. and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p=0.001. The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities, whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading.

  13. Fifty-year follow-up and Strampelli anterior chamber intraocular lens.

    Science.gov (United States)

    Oakley, Carmen L; Nigro, Matthew A; Vote, Brendan J

    2015-01-01

    The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era. The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era.

  14. A rapid method for measuring intraocular lens power in vitro with a focimeter.

    Science.gov (United States)

    García-Domene, Mari Carmen; Díez-Ajenjo, María Amparo; Peris-Martínez, Cristina; Navea, Amparo; Artigas, José María

    2015-11-01

    In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.

  15. CORRECTION OF HIGH MYOPIA WITH THE WORST MYOPIA CLAW INTRAOCULAR-LENS

    NARCIS (Netherlands)

    LANDESZ, M; WORST, JGF; SIERTSEMA, JV; VANRIJ, G

    1995-01-01

    BACKGROUND: Phakic anterior chamber lenses is one of the modalities used to correct high myopia, We report the initial results of our prospective study on the Worst myopia claw intraocular lens (IOL) that is fixated to the anterior iris, METHODS: We studied 35 eyes in 18 patients with a preoperative

  16. Case of late-onset corneal decompensation after iris-fixated phakic intraocular lens implantation.

    NARCIS (Netherlands)

    Eijden, R. van; Vries, N.E. de; Cruysberg, L.P.J.; Webers, C.A.; Berenschot, T.; Nuijts, R.M.

    2009-01-01

    A 48-year-old myopic patient with bilateral anterior chamber depth of 3.1 mm and endothelial cell density (ECD) of 2525 cells/mm(2) and 2638 cells/mm(2) preoperatively had bilateral implantation of an Artisan iris-fixated phakic intraocular lens (pIOL). Five years postoperatively, unilateral corneal

  17. Intraocular pressure-lowering effect of oral paracetamol and its in vitro corneal penetration properties

    Directory of Open Access Journals (Sweden)

    Mohamed N

    2013-01-01

    Full Text Available Nabiel Mohamed, David MeyerDivision of Ophthalmology, Faculty of Medicine and Health Sciences, University of Stellenbosch, Cape Town, South AfricaBackground: Several studies have confirmed the ability of cannabinoids to reduce intraocular pressure. Experimental data recently demonstrated unequivocally that the analgesic effect of paracetamol is due to its indirect action on cannabinoid receptors. The question then arises as to whether paracetamol can reduce intraocular pressure via its effect on intraocular cannabinoid receptors.Methods: A 2-week, prospective, randomized, controlled, single-center, parallel-group pilot study was carried out to determine the efficacy and safety of paracetamol 1 g orally administered every 6 hours in adult patients with primary or secondary open angle glaucoma as compared with topical levobunolol 0.5% twice a day. Patient well-being was closely monitored throughout the study and focused on hepatic safety in accordance with Drug-Induced Liver Injury Network criteria. The in vitro diffusion kinetics of acetaminophen in a phosphate-buffered solution in rabbit and human corneas was also investigated, with the view to a topical application.Results: Eighteen adult patients were enrolled in the study, with nine in the topical levobunolol group and nine in the oral paracetamol group. In the levobunolol group, the mean reduction in intraocular pressure at day 7 was 7.5 mmHg (P < 0.008 and at day 14 was 9.1 mmHg (P < 0.005, from a mean baseline intraocular pressure of 29.6 mmHg. The corresponding figures for the paracetamol group were 8.8 mmHg (P < 0.0004 at day 7 and 6.5 mmHg (P < 0.004 at day 14, from a mean baseline intraocular pressure of 29.4 mmHg. Both study regimens were well tolerated. No serious treatment-related adverse events were reported in either of the treatment groups. Liver function tests, systolic/diastolic blood pressure, or heart rate remained unchanged in both groups during the 2 weeks of the study. In

  18. 亲水性丙烯酸酯人工晶状体植入后的生物相容性和并发症%Hydrophilic acrylic intraocular lens:biocompatibility and complications following implantation

    Institute of Scientific and Technical Information of China (English)

    魏芬; 艾明

    2015-01-01

    BACKGROUND:Hydrophilic acrylic materials with good biocompatibility have been widely used in clinic. However, there are some problems about the biocompatibility and safety of hydrophilic acrylic intraocular lens after long-term clinical application. OBJECTIVE:To discuss the biocompatibility and stability issues and corresponding processing methods after hydrophilic acrylic intraocular lens implantation. METHODS:A computer-based search of Wanfang and PubMed database was performed for articles related to clinical application of hydrophilic acrylic intraocular lens published from 2005 to 2014. The keywords were “hydrophilic acrylic,intraocular lens” in Chinese and English, respectively. A total of 618 articles were initialy retrieved, and finaly 35 articles were included in result analysis. RESULTS AND CONCLUSION:As the hydrophilic acrylic intraocular lens is foldable, a smal incision is required for implantation and the operation is simple that cause less damage to the patients. In addition, the hydrophilic acrylic intraocular lens has poor bacterial and inflammatory cel adhesion, which leads to a low probability of infective endophthalmitis after implantation. But there is a high incidence of posterior capsule opacification as wel as some refractive errors and visual quality problems after implantation. Taken together, to solve these problems depends on the continuous improvements and updates of intraocular lens materials and designs.%背景:亲水性丙烯酸酯材料的生物相容性良好,在临床得到广泛的应用。但随着亲水性丙烯酸酯人工晶状体临床应用的时间延长,其长期的生物相容性及稳定性问题逐渐显现。目的:讨论亲水性丙烯酸酯人工晶状体植入后的生物相容性及稳定性问题和处理方法。方法:应用计算机检索万方数据库及PubMed数据库2005至2014年与亲水性丙烯酸酯人工晶状体临床应用相关的文献,中文检索词为“亲水性丙烯酸酯

  19. Experimental differentiation of intraocular masses using ultrahigh-field magnetic resonance imaging--a case series.

    Directory of Open Access Journals (Sweden)

    Karen Falke

    Full Text Available PURPOSE: The case reports presented here were compiled to demonstrate the potential for improved diagnosis and monitoring of disease progress of intraocular lesions using ultrahigh-field magnetic resonance microscopy (MRM at 7.1 Tesla. METHODS: High-resolution ex vivo ocular magnetic resonance (MR images were acquired on an ultrahigh-field MR system (7.1 Tesla, ClinScan, Bruker BioScan, Germany using a 2-channel coil with 4 coil elements and T2-weighted turbo spin echo (TSE sequences of human eyes enucleated because of different intraocular lesions. Imaging parameters were: 40×40 mm field of view, 512×512 matrix, and 700 µm slice thickness. The results were correlated with in vivo ultrasound and histology of the enucleated eyes. RESULTS: Imaging was performed in enucleated eyes with choroidal melanoma, malignant melanoma of iris and ciliary body with scleral perforation, ciliary body melanoma, intraocular metastasis of esophageal cancer, subretinal bleeding in the presence of perforated corneal ulcer, hemorrhagic choroidal detachment, and premature retinopathy with phthisis and ossification of bulbar structures. MR imaging allowed differentiation between solid and cystic tumor components. In case of hemorrhage, fluid-fluid levels were identified. Melanin and calcifications caused significant hypointensity. Microstructural features of eye lesions identified by MRM were confirmed by histology. CONCLUSION: This study demonstrates the potential of MRM for the visualization and differential diagnosis of intraocular lesions. At present, the narrow bore of the magnet still limits the use of this technology in humans in vivo. Further advances in ultrahigh-field MR imaging will permit visualization of tumor extent and evaluation of nonclassified intraocular structures in the near future.

  20. Delayed-onset endophthalmitis associated with corneal suture infections

    OpenAIRE

    Henry, Christopher R.; Flynn Jr., Harry W.; Miller, Darlene; Schefler, Amy C; Forster, Richard K.; Alfonso, Eduardo C.

    2013-01-01

    Background The purpose of the current study was to report the microbiology, risk factors, and treatment outcomes in patients with delayed-onset endophthalmitis associated with corneal suture infections. For this retrospective consecutive case series, a search of the ocular microbiology department database was performed to identify all patients with positive corneal and intraocular cultures (anterior chamber and/or vitreous) between 01 January 1995 and 01 January 2010. A subset of patients wit...

  1. [The effect of crystalline lens extraction on intraocular pressure in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Macarie, S; Macarie, Daniela

    2013-01-01

    This issue presents the results of a study on patients with cataract and primary open angle glaucoma who suffered lens extraction for cataract. We analise the effects of the lens extraction on the level of intraocular pressure at this patients.

  2. Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Ya-wen Guo

    2014-01-01

    Full Text Available Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. Results. The hydrophilic acrylic IOLs showed significantly lower straylight values than those of the hydrophobic acrylic IOLs in dilated pupils at 1 week and 1 month after surgery (P0.05. Moreover, no significant difference was found in straylight between natural and dilated pupils in each group at 1 week and 1 month postoperatively (P>0.05. Conclusions. Although the hydrophobic acrylic IOL induced more intraocular straylight, straylight differences among the 3 IOLs were minimal. Pupil size showed no effect on intraocular straylight; the intraocular straylight was stable 1 week after surgery.

  3. Opportunistic ocular infections in AIDS

    Institute of Scientific and Technical Information of China (English)

    Shikha Baisakhiya DOMS; FGO

    2008-01-01

    As the number of HIV infected patients is multiplying exponentially day by day so are the associated ocular complications.The increasing longevity of individuals with HIV disease has resulted in greater numbers of pa-tients with ocular opportunistic infection.By the means of this article we describe various opportunistic ocular infections in AIDS and their clinical manifestations,discussed under four headings;1 )adnexal manifestation;2)anterior segment manifestation;3)posterior segment manifestation;4)neuro ophthalmic manifestation . Herpes zoster ophthalmicus,molluscum contagiosum and Kaposi sarcoma are common adnexal manifestations. Molluscum contagiosum being the commonest.Varicella Zoster Virus (VZV)and herpes simplex virus (HSV) most commonly cause infectious keratitis in HIV-positive patients .As compared to the immunocompetent indi-viduals the frequency of bacterial and fungal keratitis is not more in HIV patients,but it tends to be more se-vere.Posterior segment structures involved in HIV-positive patients include the retina,choroid,and optic nerve head.The herpesvirus family is implicated most commonly in infections of the retina and choroid in HIV positive patients.CMV is the most common cause of retinitis and the commonest intraocular infection in AIDS. Atypical presentations resistance to conventional treatment and higher rate of recurrence make the diagnosis and therapeutic intervention more difficult and challenging.In addition,in one eye,several infections may occur at the same time,rendering the situation more difficult.

  4. Linfoma intra-ocular primário de células tipo B: relato de caso Primary intraocular B-cell lymphoma: case report

    Directory of Open Access Journals (Sweden)

    Marcela Cypel

    2007-08-01

    Full Text Available O linfoma não-Hodgkin primariamente intra-ocular é raro, e caracterizado por uma forma extranodal que pode envolver retina, espaço sub-retiniano, vítreo e nervo óptico. Ocorre independente ou associado ao linfoma do sistema nervoso central e freqüentemente na forma de uveíte de difícil tratamento. Esta forma de linfoma é um dos tumores intra-oculares mais desafiantes de se diagnosticar. Relatamos um caso de linfoma não-Hodgkin intra-ocular difuso de células grandes tipo B numa paciente de 47 anos e cuja manifestação inicial foi uma uveíte posterior; enfatizamos a importância de investigação detalhada e da avaliação sistêmica; pois esta é a forma mais freqüente de acometimento ocular. Com esse relato esperamos abordar os principais aspectos desde quadro clínico até diagnóstico chamando a atenção para essa doença que muitas vezes aparece inicialmente com sintomas vagos e inespecíficos.Ocular non-Hodgkin's lymphoma is a rare condition that can involve the retina, the vitreous and the optic nerve. It can occur alone or can be associated with lymphoma of the central nervous system and a frequent manifestation is a posterior uveitis of difficult treatment. This kind of ocular tumor is difficult and a challenge to diagnosis. We describe a case of non-Hodgkin's intraocular B-cell lymphoma in a 47-year-old woman who had a posterior uveitis as the first manifestation. We emphasize the importance of a careful investigation and of the general clinical examination since this is the most common type in the eye. We expect to call the attention to this disease that many times appears in an unspecific form with unspecific symptoms.

  5. INTRAOCULAR TRANSMISSIBLE VENEREAL TUMOR IN A DOG TUMOR VENÉREO TRANSMISSÍVEL INTRA-OCULAR EM CÃO

    Directory of Open Access Journals (Sweden)

    Geórgia Nadalini Rodrigues

    2001-02-01

    Full Text Available Canine transmissible venereal tumor (TVT is a round cell neoplasm occurring on the external genital mucosa of male and female dogs. Transmission is by cell implantation during coitus, licking, or other interaction between an affected dog and a susceptible host. Metastasis of the tumor rarely occurs. This report describes an unusual presentation of TVT with intraocular involvement and inguinal lymph nodes metastasis. The subject was a six-year-old, intact, male, Brazilian Terrier dog with a history of abnormal masses in the right eye, penis and several subcutaneous nodules in the inguinal area. Histopathological examination of the eye specimens as well as cytologic examination of penile mass and subcutaneous nodules revealed similar findings. The examination revealed round cells containing a large nuclei with prominent, central located nucleoli and a pale cytoplasm containing few small, clear round vacuoles. Histologically, the subcutaneous nodules in the inguinal area were lymph nodes. The diagnosis of TVT with intraocular involvement and lymph nodes metastasis was based on clinical, cytologic and histopathologic findings.Tumor venéreo transmissível (TVT é uma neoplasia de células redondas que acomete a mucosa genital externa de cães, machos e fêmeas. A transmissão decorre da implantação de células tumorais durante o coito, brigas ou interações entre animais portadores e susceptíveis. Existem relatos referindo-se a localizações atípicas do TVT, mas metástases raramente ocorrem. O presente relato descreve um caso incomum de TVT, com acometimento intra-ocular e metástases nos linfonodos ingüinais, num cão Terrier Brasileiro, com seis anos de idade. O animal apresentava massas anormais de tecido no olho direito, extremidade do pênis e aumento de volume de linfonodos da região ingüinal. A histopatologia do globo ocular e as citologias da massa peniana e dos nódulos subcutâneos evidenciaram aspectos citológicos semelhantes

  6. Biocompatibility of intraocular lens materials%人工晶体材料的生物相容性特征★

    Institute of Scientific and Technical Information of China (English)

    王洋; 韩宏光

    2013-01-01

      BACKGROUND: The visual recovery and complications of the cataract patients are various after different intraocular lens materials implantation, so the selection of appropriate intraocular lens materials is the key of the research. OBJECTIVE: To investigate the properties and biocompatibility of intraocular lens materials. METHODS: The materials were classified according to the hardness and location of the intraocular lens after implantation in order to analyze the pros and cons of the intraocular lens thus guiding the patients to select the appropriate intraocular lens for implantation. The properties and biocompatibility of the commonly used intraocular lens materials were evaluated. RESUTLS AND CONCLUSION: Polymethylmethacrylate intraocular lens is the first choice of rigid material, but it cannot tolerate autoclaving. Acrylic intraocular lens is the soft and foldable intraocular lens that has the similar optical and biological properties with polymethylmethacrylate intraocular lens, and it can improve the visual acuity after implantation with less complications. Posterior capsular opacification is the most important indicator for biocompatibility evaluation which is related with the material and design of intraocular lens. The stability of intraocular lens in the capsular bag is also the indicator to evaluate the biocompatibility. The material properties, biocompatibility, and visual function should be taking into consideration in the design and selection of intraocular lens materials. Guarantee the efficacy after intraocular lens implantation and reduce the incidence of complications, so that to get vision rehabilitation for the cataract patients.%  背景:白内障患者植入不同材料人工晶体治疗后的视力恢复情况和并发症有所不同,选择适宜的人工晶体材料是研究的关键。目的:探讨人工晶体材料的特征和生物相容性。方法:按人工晶体的硬度和植入后不同位置将材料进行分类

  7. Development of a hydrophobic polymer composition with improved biocompatibility for making foldable intraocular lenses

    Science.gov (United States)

    Haldar, R. S.; Chauhan, R.; Kapoor, K.; Niyogi, U. K.

    2014-05-01

    A hydrophobic composition for foldable intraocular lenses was developed by copolymerizing phenyl ethyl acrylate, phenyl ethyl methacrylate and butanediol diacrylate by gamma irradiation. Aqueous solution of heparin, a biocompatibilizer absorbed in hydroxyethyl methacrylate was added to the monomer mixture before irradiation to impart desired level of hydrophilicity and improved biocompatibility to the hydrophobic composition. Ketorolac tromethamine, an anti-inflammatory agent and L-glutathione, an antioxidant were added to the composition as functional additive for exhibiting improved performance while in use. Concentrations of monomers, biocompatibilizer and functional additives were optimized to develop an advanced material for foldable intraocular lenses. Transmittance, refractive index, Abbe number, hardness, tensile strength, flexibility and foldability were studied on the final composition. Scanning electron microscopic study, differential scanning calorimetric analysis, leachability and viscometry confirmed the permanent incorporation of additives into the polymer. Results of haemocompatibility, tissue implantation and cytotoxicity confirm that the biocompatibility of the base polymer was improved by incorporation of heparin.

  8. "Effect of topical timolol on intraocular pressure in the presence of systemic indomethacin in normal subjects"

    Directory of Open Access Journals (Sweden)

    Sud R

    1988-01-01

    Full Text Available In the present study on 60 normal subjects, the effect of 0.5% timolol eye drops on intraocular tension was assessed in the presence of oral indomethacin. The subjects were categorized in four groups for comparing the results. Also the side effects of timolol maleate were noted. The following conclusions were made:- 1. In cases in whom indomethacin was given along with timolol drops, average fall in intraocular tension was almost identical with those in whom timolol alone was used. 2. The ocular hypotensive effect of timolol maleate eve drops is not attenuated by indomethacin given orally; but before we can conclude that the simultaneous administration of timolol maleate eye drops and indomethacin is entirely without risk of attenuation. We must study the effect of combined administration in patients with glaucoma.

  9. Closure of a persistent cyclodialysis cleft using the haptics of a normal-sized intraocular lens.

    Science.gov (United States)

    Shentu, Xingchao; Zhu, Yanan; Tang, Yelei

    2011-11-01

    A 50-year-old man suffering from hypotony in the right eye caused by a traumatic cyclodialysis and complicated by a choroidal detachment and cataract was treated in our clinic. After an unsuccessful direct cyclopexy, phacoemulsification was performed and a normal-sized single-piece polymethyl methacrylate posterior chamber intraocular lens (PMMA PCIOL) was inserted into the ciliary sulcus, with the haptic rotated toward the cyclodialysis cleft. Postoperatively, the corrected visual acuity improved to 20/20, and the intraocular pressure returned to normal. Ultrasound biomicroscopy showed the closure of the cleft. Phacoemulsification with a normal-sized PMMA PCIOL inserted into the ciliary sulcus is a safe, effective and technically simple surgical treatment for small cyclodialysis induced hypotony complicated by cataract. Internal compression of the cleft by the haptic of a normal sized IOL along with postoperative inflammation led to scarring and closure of the cleft.

  10. Effects of intraocular mescaline and LSD on visual-evoked responses in the rat.

    Science.gov (United States)

    Eells, J T; Wilkison, D M

    1989-01-01

    The effects of mescaline and LSD on the flash-evoked cortical potential (FEP) were determined in unrestrained rats with chronically-implanted electrodes. Systemic administration of mescaline or LSD significantly attenuated the primary component of the FEP at three stimulus intensities with the greatest effect observed 60-90 minutes following drug administration. The magnitude and specificity of the effects of these agents on the primary response suggest that they produce deficits in conduction through the retino-geniculato-cortical system. The serotonin receptor antagonists, cyproheptadine and methysergide, antagonized the mescaline-induced depression of the FEP in accordance with neurochemical and behavioral evidence that mescaline acts as a partial agonist on serotonin receptors. Topical or intraocular administration of atropine antagonized the actions of systemically-administered mescaline. In addition, intraocular administration of mescaline or LSD attenuated the FEP indicative of an action of these hallucinogens on visual processing in the retina which is modulated by muscarinic receptor activity.

  11. Delivery of Intraocular Triamcinolone Acetonide in the Treatment of Macular Edema

    Directory of Open Access Journals (Sweden)

    Brent Siesky

    2012-03-01

    Full Text Available Macular edema (ME is one of the eventual outcomes of various intraocular and systemic pathologies. The pathogenesis for ME is not yet entirely understood; however, some of the common risk factors for its development have been identified. While this investigation will not discuss the numerous etiologies of ME in detail, it appraises the two most widely studied delivery modalities of intraocular corticosteroids in the treatment of ME—intravitreal injection (IVI and sub-Tenon’s infusion (STI. A thorough review of the medical literature was conducted to identify the efficacy and safety of IVI and STI, specifically for the administration of triamcinolone acetonide (TA, in the setting of ME in an attempt to elucidate a preferred steroid delivery modality for treatment of ME.

  12. The Changes of Quality of Life in the Patients after Phacoemulsification with Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Jiewei Liu; Jingjing Xu; Mingguang He

    2004-01-01

    Purpose: To investigate the improvement and maintenance of the quality of life in the patients after phacoemulsification with intraocular lens implantation.Methods :The study population consisted of 116 patients receiving phacoemulsification with intraocular lens implantation. They were interviewed using the quality of life questionnaire, and the clinical outcomes were evaluated before surgery and at 1 week, 1month, 3 months, 6 months after surgery respectively.Results:Patients reported similar scores of quality of life and all the four subscales among 1-week, 1-month , 3-month and 6-month follow-up visit after surgery, all of which were higher than the scores before surgery.Conclusion: Patients receiving phacoemulsification reported rapid improvement in quality of life after surgery, and the quality of life scores were not changed significantly from 1week to 6 months after surgery.

  13. Implantation of iris-claw Artisan intraocular lens for aphakia in Fuchs′ heterochromic iridocyclitis

    Directory of Open Access Journals (Sweden)

    Ahmad Kheirkhah

    2014-01-01

    Full Text Available Implantation of iris-claw Artisan intraocular lens (IOL is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs′ heterochromic iridocyclitis (FHI due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphakia with no capsular support due to a previous complicated cataract surgery. Enclavation was easily performed and no intraoperative complication was noted. Postoperative course was uneventful with no significant anterior chamber inflammation during 12 months of follow-up. Although there were few deposits on the IOL surface, the patient achieved a best-corrected visual acuity of 20/20 without developing glaucoma or other complications. Therefore, Artisan IOL may be considered for correction of aphakia in patients with FHI. However, studies on large number of patients are required to evaluate safety of the procedure.

  14. Intraocular lens power calculation by measuring axial length with partial optical coherence and ultrasonic biometry

    OpenAIRE

    Beatriz Machado Fontes; Bruno Machado Fontes; Elaine Castro

    2011-01-01

    PURPOSE: To compare the achieved refractive outcomes of patients undergoing cataract surgery with intraocular lens (IOL) power calculation performed by conventional immersion ultrasound (US) or partial coherence interferometry (PCI). METHODS: Prospective, comparative case series. Patients undergoing cataract surgery were randomly divided in two groups with regard to the IOL power calculation method. Group 1 had calculations performed by PCI (IOL Master; Carl Zeiss Meditec), while US was used ...

  15. Intraocular Pressure in Eyes Receiving Intravitreal Antivascular Endothelial Growth Factor Injections

    OpenAIRE

    Lemos, V; Cabugueira, A; de Noronha, M; Abegão Pinto, L; Reina, M.; Branco, J; Gomes, T

    2015-01-01

    PURPOSE: The aim of the this study was to determine the effect of intravitreal antivascular endothelial growth factor injections on intraocular pressure (IOP) and identify possible risk factors for the development of increased IOP. MATERIALS AND METHODS: This prospective study included a total of 106 eyes receiving intravitreal injection of bevacizumab as treatment for macular edema or active choroidal neovascularization. IOP was measured by Goldmann applanation tonometry immediately be...

  16. [Iris suture fixation of posterior-chamber elastic intraocular lens in ligament apparatus laxity].

    Science.gov (United States)

    Pashtaev, N P; Bat'kov, E N; Zotov, V V

    2010-01-01

    An original MIOL-23 multifocal elastic intraocular lens (IOL) was used to operate 5 eyes with acquired lens dislocation and traumatic cataract. By making self-sealing tunnel incision, ILO was implanted into the capsular sac and sutured to the iris. MIOL-23 implantation caused an increase in mean visual acuity. The IOL took up a correct position. Elastic IOL implantation with iris suture fixation is an efficient and safe mode of additional ILO support. PMID:20645577

  17. Surgical management of spontaneous in-the-bag intraocular lens and capsular tension ring complex dislocation

    Directory of Open Access Journals (Sweden)

    Uzeyir Gunenc

    2014-01-01

    Full Text Available We describe a technique to manage late spontaneous intraocular lens (IOL and capsular tension ring (CTR dislocation within the intact capsular bag. The subluxated IOL and CTR complex can be positioned in a closed chamber and fixed to the pars plana at both 3 and 9 o′clock quadrants with the presented ab externo direct scleral suturation technique which provides an easy, safe and effective surgical option for such cases.

  18. Correlation of the intraocular pressure with increased intracranial pressure in rabbits

    Directory of Open Access Journals (Sweden)

    Eskandari H

    2000-08-01

    Full Text Available Although measurement of intracranial pressure by noninvasive methods has been suggested, but mainly invasive methods are used for this purpose-Increase in episcleral venous pressure can be expected to result in a linear increase in intraocular pressure. Congested oculat veins with capillary leakage and hemorrhage are seen when the ICP is increased, thus theoretically measurement of intraocular pressure can be a procedure for estimation of the ICP. This study was performed to find whether there is andy relationship between intraocular pressure and ICP, so we used 12 albino rabbits in two divided groups. Our study was not designed to elucidate the mechanism of change but merely to record any changes observed. All measures except an increase in ICP were applied on the test group as well as on the control group. After general anesthesia with the combination of ketamin, rampune, and pentobarbital a burr hole was made in the lambda region of the skull and a cannula was placed in the subdural space. The ICP in the test group increased up to 15 mmHg and was constant throughout the experiment. Intraocular pressure was measured by Schiotz tonometers afte general anesthesia, after cannulation of the skull, and immediately after increasing the ICP which was repated in 15 minutes interval for 4 hours. There was no statistical difference between the two groups (P:0.997 . results show that neither cannulation nor general anesthesia for 4 hours produce alteration in IOP in the control group nor increasing of the ICP to level of 15 mmHg produces any alteration in IOP on the test group.

  19. Treatment of dystrophic calcification on a silicone intraocular lens with pars plana vitrectomy

    OpenAIRE

    Mehta N; Goldberg RA; Shah CP

    2014-01-01

    Nitish Mehta,1 Roger A Goldberg,2 Chirag P Shah21University of Massachusetts Medical School, Worcester, MA, USA; 2Department of Retina, Ophthalmic Consultants of Boston, Boston, Massachusetts, USAPurpose: Dense, vision-obscuring calcification on the posterior aspect of silicone intraocular lenses (IOLs) is often not amenable to neodymium:yttrium-aluminum-garnet capsulotomy, and, in prior reports, has required IOL exchange. We report the successful removal of dense calcium deposition on the po...

  20. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach

    OpenAIRE

    Jeroni Nadal; Bachar Kudsieh; Ricardo P. Casaroli-Marano

    2015-01-01

    Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL) stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a ...

  1. Intraocular lens dislocation and tube shunt in the posterior chamber: a case report

    OpenAIRE

    Moreno-Montañés, Javier; Velázquez-Villoria, Alvaro; Sabater, Alfonso L.; Salinas-Alamán, Angel

    2015-01-01

    Background To describe management of a case of intraocular lens (IOL) and capsular bag (CB) dislocation in an eye with an Ahmed glaucoma valve in the posterior chamber. Case presentation A 75-year-old pseudophakic man with open-angle glaucoma and diabetic retinopathy developed neovascular glaucoma. After two intravitreous injections of bevacizumab and panretinal photocoagulation were administered, the new vessels regressed. However, goniosynechiae were observed over 360° of the angle. An Ahme...

  2. Risk Factors for Endophthalmitis and Retinal Detachment with Retained Intraocular Foreign Bodies

    OpenAIRE

    D. Wilkin Parke; Avinash Pathengay; Flynn, Harry W; Thomas Albini; Schwartz, Stephen G

    2012-01-01

    Purpose. To analyze risk factors for endophthalmitis and retinal detachment (RD) in patients with retained intraocular foreign bodies (IOFBs). Design. A retrospective, interventional, consecutive case series. Participants. All patients treated at Bascom Palmer Eye Institute for traumatic IOFBs between 1999 and 2008. Methods. Analysis of visual outcome, mechanism of injury, management, and postoperative course. Results. 108 eyes with IOFBs were identified. Endophthalmitis occurred in 7 eyes (...

  3. Risk Factors for Endophthalmitis and Retinal Detachment with Retained Intraocular Foreign Bodies

    OpenAIRE

    Parke, D. WilkinIII; Pathengay, Avinash; Flynn, Harry W.Jr.; Albini, Thomas; Schwartz, Stephen G

    2012-01-01

    Purpose. To analyze risk factors for endophthalmitis and retinal detachment (RD) in patients with retained intraocular foreign bodies (IOFBs). Design. A retrospective, interventional, consecutive case series. Participants. All patients treated at Bascom Palmer Eye Institute for traumatic IOFBs between 1999 and 2008. Methods. Analysis of visual outcome, mechanism of injury, management, and postoperative course. Results. 108 eyes with IOFBs were identified. Endophthalmitis occurred in 7 eyes (6...

  4. New Management of Angle-closure Glaucoma by Phacoemulsification with Foldable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Jian Ge; Yan Guo; Yizhi Liu; Mingkai Lin; Yehong Zhuo; Bing Chen; Xiuqi Chen

    2000-01-01

    Objective: To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOL) implantation. Design: Retrospective, noncontrolled interventional case series.Participants: In 36 eyes with angle-closure glaucoma (ACG), there were 18 eyes with primary acute angle-closure glaucoma (PACG), 14 eyes with primary chronic angle-closure glaucoma (PCCG), 3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle-closure glaucoma (SCCG).Intervention: Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures: Postoperative visual acuity, IOP, axial anterior chamber depth.Results: After a mean postoperative follow-up time of 8.81 ± 7.45 months, intraocular pressure was reduced from a preoperative mean of 23.81 ± 17.84 mmHg to a postoperative mean of 12.54 ± 4. 73 mmHg ( P = 0. 001 ). Mean anterior chamber depth was 1.75 ± 0.48 mm preoperatively and 2.29 ± 0.38 mm postoperatively ( P = 0. 000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0. 01 to 0. 7 (20/200 to 20/30) postoperatively, which was better than preoperative VA ranging from hand movement to 0.4 (20/50) ( P= 0. 000).Conclusion: Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma. Eye Science 2000; 16:22 ~ 28.

  5. New Management of Angle-closure Glaucoma by Phacoemulsification with Folable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    JianGE; YanGuo; 等

    2002-01-01

    Objective:To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOIL)implantation.Design:Retrospective,noncontrolled interventional case series.Participants:In 36 eyes with angle -closure glaucoma(ACG).there were 18eyes with primary acute angle-closure glaucoma(PACG),14 eyes with primary chonic angle -closure glaucoma(PCCG),3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle -closure glaucoma(SCCG).Intervention:Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures:Postoperative visual acuity,IOP,axial anterior chamber depth.Results:After a mean postoperative follow -time of 8.81±7.45 months,intraocular pressure was reduced from a preoperative mean of 23.81±17.84 mmHg to a postoperative mean of 12.54±4.73mmHg(P=0.001).Mean anterior chamber depth was 1.75±0.48 mm preoiperatively and 2.29±0.38mm postoperatively(P-0.000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0.01 to 0.7(20/200 to 20/30)postoperatively,which was better than preoperative VA ranging from hand movement to 0.4(20/50)(P=0.000).Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma.Eye Science2000;16:22-28.

  6. Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses

    OpenAIRE

    Nishi T.; Taketani F; Ueda T; Ogata N.

    2013-01-01

    Tomo Nishi, Futoshi Taketani, Tetsuo Ueda, Nahoko Ogata Department of Ophthalmology, Nara Medical University, Kashihara City, Nara, Japan Purpose: To determine the amplitude of pseudoaccommodation and higher-order aberrations with three types of implanted monofocal intraocular lenses (IOLs): aspheric yellow (IQ); spheric yellow (NT); and spheric clear (AT). Setting: Department of Ophthalmology, Nara Medical University, Nara, Japan. Methods: We studied 60 patients who underwent small incision...

  7. Use of hydroxypropylmethylcellulose 2% for removing adherent silicone oil from silicone intraocular lenses

    OpenAIRE

    Wong, S Chien; Ramkissoon, Yashin D; Lopez, Mauricio; Page, Kristopher; Ivan P. Parkin; Sullivan, Paul M

    2009-01-01

    Abstract Background / aims: To investigate the effect of hydroxypropylmethylcellulose (HPMC) on the physical interaction (contact angle) between silicone oil and a silicone intraocular lens (IOL). Methods: In vitro experiments were performed, to determine the effect of HPMC (0.5%, 1% or 2%), with or without an additional simple mechanical manoeuvre, on the contact angle of silicone oil at the surface of both silicone and acrylic (control) IOLs. A balanced salt solu...

  8. Effects of glaucoma medications on the cardiorespiratory and intraocular pressure status of newly diagnosed glaucoma patients

    OpenAIRE

    WALDOCK, A; Snape, J; Graham, C

    2000-01-01

    AIMS—To evaluate the short term cardiovascular, respiratory, and intraocular pressure (IOP) effects of four glaucoma medications in newly diagnosed glaucoma patients.
METHODS—141 newly diagnosed glaucoma patients were recruited and underwent a full ocular, cardiovascular, and respiratory examination, including an electrocardiogram (ECG) and spirometry. They were prescribed one of four topical glaucoma medications and reviewed 3 months later. One eye of each patient was randomly chosen for ana...

  9. Assessment of the central corneal thickness and intraocular pressure in premature and full-term newborns

    OpenAIRE

    Muslubas, Isil Bahar Sayman; Oral, Ayse Yesim Aydın; Cabi, Cemalettin; Caliskan, Sinan

    2014-01-01

    Purpose: To assess the central corneal thickness (CCT) and intraocular pressure (IOP) in premature and full-term newborns. Materials and Methods: In this study, we evaluated measurements of CCT and IOP in 45 premature and 45 full-term newborns. IOP was determined with topical anesthesia using a Tono-Pen AVIA, applanation tonometer and a wire lid retractor in premature newborns undergoing screening for retinopathy. Full-term newborns were used as a control group. CCT was determined with a port...

  10. Characteristics of Optic Nerve Damage Induced by Chronic Intraocular Hypertension in Rat

    Institute of Scientific and Technical Information of China (English)

    Jiantao Wang; Jian Ge; A.A. Sadun; T.T. Lam

    2004-01-01

    Purpose:To set up the Sharma's chronic intraocular hypertension model and investigate the intraocular pressure (lOP) as well as the optic nerve damage of this model in rat.Methods:The operations of the chronic intraocular hypertension model were performed as described by Sharma in 60 male Lewis albino rats. IOP was measured using the TonoPen XL immediately after surgery and then at 5 day, 2 week or 4 week intervals. Cresyl violet staining of whole-mounted retinas was used to label retinal ganglion cells (RGCs),then RGCs were counted. Paraphenylenediamine (PPD) staining was performed in the semi-thin cross sections of optic nerve of rat, in order to know whether the axons of optic nerve were degenerated or not. Results:There were 47 rats with higher IOP after the episcleral veins cauterized in 60rats. The ratio of elevated IOP was 78.3%. The IOPs were stable in 4 weeks. After cresyl violet staining, the RGCs loss was 11.0% and 11.3% was found in the central and peripheral retina respectively after 2 weeks of increased IOP. After 4 weeks of increased lOP, the loss of RGCs was 17% for the central retina and 24.6% for the peripheral retina. In the retinas without higher IOP, there was no loss of RGCs. PPD staining showed that optic nerve of rat with about 5.3% damage of axons located at the superior temporal region. Region of affected optic nerve 1 mm posterior to the globe by light microscope showed evidence of damaged axons with axonal swelling and myelin debris.Conclusion:Sharma's chronic intraocular hypertension model is a reproducible and effective glaucoma model, which mimics human glaucoma with chronically elevation IOP and induced RGCs loss and damage of optic nerve. Eye Science 2004;20:25-29.

  11. Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant

    OpenAIRE

    Chen, Po-Jui; Saati, Saloomeh; Varma, Rohit; Humayun, Mark S.; Tai, Yu-Chong

    2010-01-01

    This paper presents an implant-based wireless pressure sensing paradigm for long-range continuous intraocular pressure (IOP) monitoring of glaucoma patients. An implantable parylene-based pressure sensor has been developed, featuring an electrical LC-tank resonant circuit for passive wireless sensing without power consumption on the implanted site. The sensor is microfabricated with the use of parylene C (poly-chlorop- xylylene) to create a flexible coil substrate that ca...

  12. The Impact of Multifocal Intraocular Lens in Retinal Imaging with Optical Coherence Tomography

    OpenAIRE

    Dias-Santos, A; Costa, L; Lemos, V; Anjos, R.; Vicente, A.(IFPA, Dep. AGO, Université de Liège, Bat B5, Sart-Tilman, B-4000, Liège 1, Belgium); Ferreira, J; Cunha, JP

    2015-01-01

    Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twent...

  13. Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye

    OpenAIRE

    Fujikado, Takashi

    2014-01-01

    Takashi Fujikado,1 Makoto Saika2 1Department of Applied Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan; 2Research and Development Department of Topcon Corporation, Tokyo, Japan Purpose: To examine the effect of misalignment (decentration and tilt) of intraocular lenses (IOLs) on retinal image quality using a water-immersed model eye with corneal spherical aberration adjusted to the values found in normal human eyes (spherical aberration 0.25 µm; pupil d...

  14. Comparison of retinal image quality with spherical and customized aspheric intraocular lenses

    OpenAIRE

    Guo, Huanqing; Goncharov, Alexander V.; Dainty, Chris

    2012-01-01

    We hypothesize that an intraocular lens (IOL) with higher-order aspheric surfaces customized for an individual eye provides improved retinal image quality, despite the misalignments that accompany cataract surgery. To test this hypothesis, ray-tracing eye models were used to investigate 10 designs of mono-focal single lens IOLs with rotationally symmetric spherical, aspheric, and customized surfaces. Retinal image quality of pseudo-phakic eyes using these IOLs together with individual variati...

  15. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Tendal, Britta;

    2016-01-01

    TOPIC: We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were...... evaluated as surgical complications and residual astigmatism. CLINICAL RELEVANCE: Postoperative astigmatism is an important cause of suboptimal UCDVA and need for distance spectacles. Toric IOLs may correct for preexisting corneal astigmatism at the time of surgery. METHODS: We performed a systematic...

  16. Intraocular pressure and influencing systemic health parameters in a Korean population

    OpenAIRE

    Young Sang Han; Ji Woong Lee; Jong Soo Lee

    2014-01-01

    Aim: To evaluate the relationship between intraocular pressure (IOP) and systemic health parameters such as age, gender, body mass index (BMI), total cholesterol, high density lipoprotein (HDL), and triglyceride (TG) in a Korean population. Materials and Methods: A total of 30,893 healthy subjects underwent automated multiphasic tests, including non-contact tonometry, automated perimetry, fundus photography, and blood samplings for total cholesterol, HDL, and TG. Seven age groups were divided...

  17. Evaluation of in vitro glistening formation in hydrophobic acrylic intraocular lenses

    OpenAIRE

    Thomes BE; Callaghan TA

    2013-01-01

    Brett E Thomes, Thomas A CallaghanAlcon Research Ltd (A Novartis Company), Fort Worth, TX, USAPurpose: To evaluate the impact of continuous manufacturing process improvements on glistening formation in AcrySof hydrophobic acrylic intraocular lenses (IOLs) by comparing lenses manufactured in 2003 with lenses manufactured in 2012.Methods: Glistenings were experimentally created as aqueous-filled microvacuoles utilizing an accelerated laboratory method by immersing the lens in water at 45&de...

  18. Toric intraocular lenses for correction of astigmatism in keratoconus and after corneal surgery

    OpenAIRE

    Mol, Ilse

    2016-01-01

    Ilse EMA Mol,1,2 Bart TH Van Dooren1,2 1Department of Ophthalmology, Amphia Hospital, Breda, 2Department of Ophthalmology, Erasmus Medical Center, Rotterdam, the Netherlands Purpose: To describe the results of cataract extraction with toric intraocular lens (IOL) implantation in patients with preexisting astigmatism from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery).Methods: Cataract patients with topographically stable, fairly regular (although sometim...

  19. Impact of the Topical Ophthalmic Corticosteroid Loteprednol Etabonate on Intraocular Pressure

    OpenAIRE

    Sheppard, John D.; Timothy L Comstock; Cavet, Megan E.

    2016-01-01

    Corticosteroids are a mainstay therapeutic option for the treatment of ocular inflammation. However, safety remains a concern for clinicians, particularly with long-term use. Though highly effective at suppressing inflammatory and allergic responses, topical ophthalmic corticosteroids carry an inherent risk of side effects, including elevated intraocular pressure (IOP), a risk factor for the development of glaucoma. The corticosteroid loteprednol etabonate (LE) contains an ester rather than a...

  20. Two cases of uveitis masquerade syndrome caused by bilateral intraocular large B-cell lymphoma

    Directory of Open Access Journals (Sweden)

    Jovanović Svetlana

    2013-01-01

    Full Text Available Introduction. Sometimes it is not easy to clinically recognize subtle differences between intraocular lymphoma and noninfectious uveitis. The most common lymphoma subtype involving the eye is B-cell lymphoma. Case report. We presented two patients aged 59 and 58 years with infiltration of the subretinal space with a large B-cell non-Hodgkin intraocular lymphoma. The patients originally had clinically masked syndrome in the form of intermediate uveitis. As it was a corticosteroid-resistant uveitis, we focused on the possible diagnosis of neoplastic causes of this syndrome. During hospitalization, the neurological symptoms emerged and multiple subretinal changes accompanied by yellowish white patches of retinal pigment epithelium with signs of vitritis, which made us suspect the intraocular lymphoma. Endocranial magnetic resonance imaging established tumorous infiltration in the region of the left hemisphere of the cerebellum. The histopathological finding confirmed the diagnosis of large B-cell non-Hodgkin lymphoma of risk moderate degree, immunoblast - centroblast cytological type. The other patient had clinical chronic uveitis accompanied by yellowish shaped white echographic changes of the retina and localized changes in the level of the subretina. The diagnosis of lymphoma was made by brain biopsy. Conclusion. Uveitis masquerade syndrome should be considered in all patients over 40 years with idiopathic steroid-resistant uveitis. Treatment begun on time can affect the course and improve the prognosis of uveitis masquerade syndrome (UMS and systemic disease.

  1. Successful Removal of Large Intraocular Foreign Body by 25-Gauge Microincision Vitrectomy Surgery

    Directory of Open Access Journals (Sweden)

    Hiroshi Kunikata

    2011-01-01

    Full Text Available We describe a new technique for removing a large intraocular foreign body by 25-gauge microincision vitrectomy surgery (25G-MIVS. Noncomparative interventional case series were performed at a single centre. Two patients with a long smooth intraocular vitreal foreign body underwent phacoemulsification and aspiration, intraocular lens implantation, 25G-MIVS, and extraction of the foreign body. The foreign body was removed through a posterior capsulorhexis, anterior continuous curvilinear capsulorhexis, and a corneal incision. In both cases, the foreign body was safely removed through the corneal incision, and IOL was implanted and well positioned. The surgical incision did not require suturing. No postoperative complications associated with this technique were found. The corneal endothelial cell density was maintained over 2000 cells/mm2 in both cases during recent follow-up examinations. Our findings indicate that 25G-MIVS with this technique can be used to extract a long slender smooth foreign body. It is safe, without complications, and can be performed without enlarging the 25-gauge sclerotomy.

  2. Acute Central Retinal Artery Occlusion Associated with Intraocular Silicone Oil Tamponade

    Directory of Open Access Journals (Sweden)

    Mehmet Yasin Teke

    2012-05-01

    Full Text Available Many systemic and ocular factors may cause acute central retinal artery occlusion (CRAO. Herein, we aimed to describe a case of CRAO due to intraocular silicone oil (SO tamponade. To the best of our knowledge, a case like our has not been reported previously. A 58-yearold male patient had undergone combined pars plana vitrectomy-lensectomy and intraocular SO for lens luxation and vitreus hemorrhage associated with a blunt ocular trauma in his right eye. Two weeks after the surgery, he presented with acute vision loss in the same eye. He was diagnosed with acute CRAO and it should be related with mechanical press or raised intraocular pressure (IOP associated with SO. He was treated by partial removal of SO immediately. In spite of the regression of retina edema, his visual acuity did not improve due to optic atrophy. SO may cause CRAO due to raised IOP and/or its mechanical pressure and this complication must be kept in mind. (Turk J Oph thal mol 2012; 42: 238-40

  3. Optical aberrations of intraocular lenses measured in vivo and in vitro

    Science.gov (United States)

    Barbero, Sergio; Marcos, Susana; Jiménez-Alfaro, Ignacio

    2003-10-01

    Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not significantly different from aberrations in eyes before cataract surgery or from previously reported aberrations in healthy eyes of the same age. However, aberrations in pseudophakic eyes are significantly higher than in young eyes. We found a slight increase of corneal aberrations after surgery. The aberrations of the IOL and the lack of balance of the corneal spherical aberrations by the spherical aberrations of the intraocular lens also degraded the optical quality in pseudophakic eyes. We also measured the aberrations of the IOL in vitro, using an eye cell model, and simulated the aberrations of the IOL on the basis of the IOL's physical parameters. We found a good agreement among in vivo, in vitro, and simulated measures of spherical aberration: Unlike the spherical aberration of the young crystalline lens, which tends to be negative, the spherical aberration of the IOL is positive and increases with lens power. Computer simulations and in vitro measurements show that tilts and decentrations might be contributors to the increased third-order aberrations in vivo in comparison with in vitro measurements.

  4. [Results of intraocular lens implantation in cataract complicated by medium and high myopia].

    Science.gov (United States)

    Plotnikova, Iu A; Chuprov, A D; Volkov, D V

    2001-01-01

    Results of surgical treatment of cataract complicated by medium and high myopia are analyzed. The main group consisted of 90 patients (96 eyes) subjected to extracapsular cataract extraction with implantation of posterior-chamber intraocular lenses and the reference group of 128 patients in whom cataract was extracted without implantation of artificial lens. The study included creation of a mathematical model of myopic eye with estimation of pressure fluctuations in various zones of the eye, developing during transposition of the vitreous during patient's movements (head movements, jumps, falling) and the damping effect of the lens in the ocular system. It was proven by mathematical calculations that transpositions of jelly fractions of the vitreous decreased by 70% in an eye with the lens in comparison with their transposition in aphakia. Clinical studies demonstrated the efficiency of intraocular correction of aphakia in high myopia: implantation of an intraocular lens decreases the risk of detachment of the retina during the postoperative period and helps attain the desired refraction. PMID:11765458

  5. Clinical Observation of 126 Cases of Sutureless Phacoemulsification with PMMA Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Yanshuang Yan; Zhengxing Mao

    2000-01-01

    Objective: To observe the safety and effect of sutureless phacoemulsification with PMMA intraocular lens (IOL) implantation.Methods: One-hundred and twenty-six cases (126 eyes) of sutureless phacoemulsification with PMMA intraocular lens (IOL) implantation were retrospected and evaluated. The surgeries were performed through a limbal tunnel incision. PMMA IOLs with 5.5mm or 6.0mm in diameter were implanted.Results: The follow-up was 3~20 months. Visual acuity of 0. 5 or better was obtained in 120 cases (95.2%), and that of 1.0 or better was obtained in 89 cases (70. 6% ).Intra-operative complications included posterior capsule rupture in 9 cases (7. 1% ) and iris injury in 7 cases(5.6% ). Postoperative complications included early corneal edema in 96 cases(76.2% ), transient intraocular pressure elevation in 5 cases(4. 3%),remnant of cortex in 1 case and leakage of incision in 1 case. M1 were properly managed with good results.Conclusion: Sutureless phacoemulsification with PMMA IOL implantation is safe even in grass-root hospitals where cataracts are harder.

  6. Stereoselectivity of satropane, a novel tropane analog, on iris muscarinic receptor activation and intraocular hypotension

    Institute of Scientific and Technical Information of China (English)

    Liang ZHU; Hong-zhuan CHEN; Li-min YANG; Yong-yao CUI; Pei-li ZHENG; Yin-yao NIU; Hao WANG; Yang LU; Qiu-shi REN; Pi-jing WEI

    2008-01-01

    Aim: To study the stereoselectivity of satropane (3-paramethylbenzene sulfonyloxy-6-acetoxy tropane), a novel tropane analog, on iris muscarinic receptor activation and intraocular hypotension. Methods: The assays for radioligand-receptor binding, the contractile responses of isolated iris muscle, the miosis response, and the intraocular hypotension of the enantiomers of satropane were investigated. Results: In the binding analysis, S(-)satropane (lesatropane) completely com-peted against the [3H]quinuclydinyl benzilate-labeled ligand at muscarinic recep-tors in the iris muscle, whereas R(+)satropane failed to completely compete. In an isolated iris contractile assay, R,S(±)satropane and S(-)satropane produced a concentration-dependent contractile response with similar efficacy and potency to that of carbachol. R(+)satropane did not induce any contractile response. In the pupil diameter measurement assay in vivo, S(-)satropane induced miosis much more effectively than pilocarpine, while R(+)satropane failed to produce any miosis. In the water loading-induced and methylcellulose-induced ocular hypertensive models, S(-)satropane, but not R(+)satropane, significantly suppressed intraocu-lar pressure at a much lower concentration than pilocarpine. Conclusion: The ago-nistic and hypotensive properties of satropane on rabbit eyes are stereoselective, with the S(-)isomer being its active form.

  7. Retropupillary Fixation of Iris-Claw Intraocular Lens for Aphakic Eyes in Children.

    Directory of Open Access Journals (Sweden)

    Martina Brandner

    Full Text Available To report outcome, complications and safety of retropupillary fixated iris-claw intraocular lenses in a pediatric population.Retrospective study.Ten consecutive pediatric patients (15 eyes underwent placement of retropupillary fixated iris-claw intraocular lenses between October 2007 and July 2013 at the Department of Ophthalmology, Medical University Graz and General Hospital Klagenfurt, Austria. Postoperative visual acuity and complications were analyzed.Median final best-corrected visual acuity improved by 0.12 logMAR from preoperative baseline. Mean postoperative spherical equivalent was -0.05 ± 1.76 D. No serious complications were observed intra- or postoperatively during the entire follow-up period of up to 40 months. One patient experienced a haptic disenclavation with IOL subluxation immediately after a car accident.Our study demonstrates that iris-claw intraocular lens implantation behind the iris is safe in children with lack of capsular support and yields excellent visual outcome with low complication rate.

  8. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    Science.gov (United States)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  9. The relationship between cytokine level and nitric oxide content in aqueous humor after intraocular lens implantation

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    AIM: To investigate the relationship between cytokine level and nitric oxide (NO) content in aqueous humor after intraocular lens implantation. METHODS: All New Zealand rabbits were divided randomly into three groups: (1) control group, (2) extracapsular cataract extraction group (ECCE), (3) extracapsular cataract extraction and posterior chamber intraocular lens implantation group (ECCE+IOL). The inflammation of all experimental rabbit eyes, including cornea edema and anterior chamber exudation were observed via zoom-photo slitlamp microscope 1,3,7,14,30 d postoperation. Meanwhile, aqueous humor was drawn for white blood cell (WBC) counting and classifying, and for NO-2/NO-3 and cytokine assay, including interleukin-2(IL-2), tumour necrosis factor-α(TNF-α). Statistics were taken by SPSS softwear. RESULTS: (1) Total WBC in aqueous humor were higher and anterior chamber exudation were more severe in ECCE+IOL group than that in ECCE group and control group. (2) The level of IL-2 and TNF-α and the content of NO-2/NO-3 in aqueous humor of ECCE+IOL group were higher than that in ECCE group and control group 1-14 d postoperation respectively, and it increased to peak value at 3-7 d postoperation and decreased gradually after two weeks postoperation. (3) The change regularity of IL-2, TNF-α and NO-2/NO-3 in each group were basically similar, i.e. when the level of cytokine (IL-2 and TNF-α) was normal, the content of NO-2/NO-3 was normal too, when the level of cytokine (IL-2 and TNF-α) increased, the content of NO-2/NO-3 increased too. CONCLUSION: The intraocular inflammation after ECCE+IOL was more severe than that after simple ECCE. NO, IL-2 and TNF-α play an important role in intraocular inflammation after intraocular lens implantation. The changes of IL-2 and TNF-α level was closely related with NO content in aqueous humor.

  10. Visual performance after the implantation of a new trifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Vryghem JC

    2013-10-01

    Full Text Available Jérôme C Vryghem,1,2 Steven Heireman1,21Brussels Eye Doctors, Brussels, Belgium; 2Clinique Saint-Jean, Brussels, BelgiumPurpose: To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens.Methods: A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients.Results: The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09. LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced.Conclusion: The introduction of a third focus in diffractive multifocal

  11. Prostaglandin E2-Glyceryl Ester: In Vivo Evidence for a Distinct Pharmacological Identity from Intraocular Pressure Studies.

    Science.gov (United States)

    Woodward, David F; Poloso, Neil J; Wang, Jenny W

    2016-08-01

    Prostaglandin E2 (PGE2)-2-glyceryl ester is a cyclo-oxygenase 2 product of the endocannabinoid 2-arachidonyl glycerol. It is claimed as pharmacologically novel, but this is complicated by rapid and irreversible isomerization to the 1(3) ester. For ocular studies, enzymatic hydrolysis of the ester moiety creates an additional complication. PG-glyceryl esters were stabilized to isomerization and hydrolysis by replacing the noncarbonyl O with NH, to form the serinolamide and propanediolamide as stable analogs of PG-2-glyceryl and PG-2-1(3) glyceryl esters, respectively. Intraocular pressure was measured in conscious dogs and conscious laser-induced ocular hypertensive monkeys. Pharmacological studies involved stable transfectants for each of the human recombinant prostanoid receptors and the isolated feline iris for prostamide activity. PGE2-serinolamide and PGE2- propanediolamide were essentially inactive at all receptors except the EP3 receptor (EC50, ∼500 nM). This obliged elucidation of EP3 receptor involvement in the intraocular pressure response to these PGE2-glycyerl ester analogs. Since the EP3 receptor agonists sulprostone and GR 63799 did not lower monkey intraocular pressure, a role for EP3 receptors in mediating the effects of PGE2-serinolamide and PGE2-propanediolamide is not indicated. PGE2-glyceryl ester (0.01% and 0.1%) substantially lowered intraocular pressure in monkeys. PGE2-propanediolamide was more efficacious than PGE2-serinolamide in lowering intraocular pressure in monkey eyes, but both appeared equieffective in dog eyes. PGE2-serinolamide dose-dependently (0.01- 0.1%) lowered intraocular pressure in both species, but PGF2 α-serinolamide was inactive. In conclusion, stable PGE2-glyceryl ester analogs lowered intraocular pressure. These findings are consistent with the presence of a PGE2-glyceryl ester-specific recognition site in the eye. PMID:27217589

  12. Prótese intra-ocular de resina acrílica em cães e gatos Acrylic resin intraocular prosthesis in dogs and cats

    Directory of Open Access Journals (Sweden)

    S.C. Rahal

    2000-08-01

    Full Text Available Foram atendidos no Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Unesp - Campus de Botucatu, 11 animais (oito cães e três gatos, com alterações oftálmicas unilaterais graves que levaram à perda total da função ocular (protrusão de globo com injúria nervosa e estrutural, perfurações de córnea com perda de conteúdo intra-ocular e endoftalmites, entre outras. Os animais, com idades entre dois meses e 10 anos, foram submetidos à evisceração e posterior inclusão de esfera de resina acrílica (metilmetacrilato na capa córneo-escleral ou escleral. As esferas foram previamente confeccionadas e esterilizadas por autoclavagem. No pós-operatório foram utilizados antiinflamatórios e antibioticoterapia tópica combinada ou não a sistêmica. O período de observação variou de 2 meses a 3 anos e os aspectos avaliados foram secreção ocular, blefarospasmo, sinais de desconforto e estética. Obtiveram-se resultados satisfatórios em oito casos. Concluiu-se que a resina acrílica pode ser uma alternativa para uso como inclusão em cavidade anoftálmica.Eleven animals (eight dogs and three cats, aged between two months and ten years were referred to the Veterinary Hospital of Faculty of Veterinary Medicine and Animal Science - Unesp, Botucatu, Brazil. These animals presented severe unilateral ophthalmic changes that lead to a total loss of ocular function, such as prolapsed eyes with nervous and structural injury, corneal damage with loss of intraocular contents or endophthalmitis among others. They were submitted to evisceration followed by the insertion of an acrylic resin prosthesis (methylmethacrylate in the corneoscleral or scleral shell. The spheres were previously made and sterilized by autoclave. The postoperative medical therapy included topical and systemic broad-spectrum antibiotics for seven days and anti-inflammatory drugs. The follow-up time varied from two months to three years. The evaluated

  13. Aderência bacteriana in vitro a lentes intra-oculares de polimetilmetacrilato e de silicone In vitro bacterial adherence to silicone and polymetylmethacrylate intraocular lenses

    Directory of Open Access Journals (Sweden)

    Claudete Inês Locatelli

    2004-04-01

    Full Text Available OBJETIVOS: Verificar a aderência bacteriana a lentes intra-oculares de silicone e de polimetilmetacrilato como possível fator de risco no desenvolvimento de endoftalmite pós-operatória, utilizando-se um modelo in vitro com três microrganismos potencialmente patogênicos. MÉTODOS: As análises foram realizadas com cepas de Staphylococcus aureus ATCC 29213, Staphylococcus epidermidis (amostra clínica e Pseudomonas aeruginosa ATCC 27853 incluindo a determinação de curvas de crescimento, testes para verificação de produção de cápsula, avaliação da hidrofobicidade, testes de aderência a diferentes materiais, microscopia óptica, microscopia eletrônica de varredura e microscopia de força atômica. RESULTADOS: A produção de cápsula e a aderência das três diferentes cepas não mostraram qualquer relação com a quantidade de microrganismos; em relação às lentes intra-oculares de polimetilmetacrilato e de silicone, não houve diferença estatisticamente significativa na aderência de S. aureus e S. epidermidis; P. aeruginosa foi o microrganismo mais aderente a ambos os materiais. A microscopia eletrônica de varredura confirmou estes achados em relação à aderência, ao peso que a microscopia de força atômica evidenciou a produção de biofilme pelas cepas de S. aureus, S. epidermidis e P. aeruginosa. CONCLUSÕES: Constatou-se, in vitro, que os materiais analisados não diferiram com relação à taxa de aderência bacteriana, porém, P. aeruginosa apresentou maior eficiência de adesão entre as bactérias testadas. Todas as cepas produziram biofilme. Silicone foi o material mais hidrofóbico, quando comparado ao polimetilmetacrilato.PURPOSE: To evaluate bacterial adherence to silicone and polymetylmethacrylate (PMMA intraocular lenses as a risk factor for postsurgery endophthalmitis by using an in vitro model with three potentially pathogenic microorganisms. METHODS: In vitro experiments were carried out with the

  14. A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery

    OpenAIRE

    Bikramjit Das; Rajiv Kumar Samal; Arup Ghosh; Ratul Kundu

    2016-01-01

    BACKGROUND: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. METHODS: Ninety adult patients were randomly assigned to study group or control group. Study group (n = 45) - Airtraq laryngoscope was used for laryngoscopy. Control group (n = 45) - conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngosc...

  15. Iris Claw versus Scleral Fixation Intraocular Lens Implantation during Pars Plana Vitrectomy

    Directory of Open Access Journals (Sweden)

    Fereydoun Farrahi

    2012-01-01

    Full Text Available Purpose: To compare the outcomes of iris claw anterior chamber intraocular lens (ICACIOL with that of scleral fixation posterior chamber intraocular lens (SF-PCIOL implantation during pars plana vitrectomy (PPV as initial surgery to correct aphakia. Methods: Twelve patients with complicated cataract surgery or trauma who had suffered nucleus, whole crystalline lens or intraocular lens (IOL drop into the vitreous cavity, and undergone PPV with IC-ACIOL implantation over a period of one year were evaluated for the purpose of this study. Uncorrected visual acuity (UCVA, best corrected visual acuity (BCVA, central corneal thickness (CCT, spherical equivalent (SE refractive error, astigmatism and complications were recorded. The results were compared to outcomes of another group of 13 patients who had previously undergone PPV with SF-PCIOL implantation. Results: Mean improvement of UCVA was greater in IC-ACIOL eyes as compared to the SF-PCIOL group (-1.17±0.28 versus -0.89±0.21 logMAR, P=0.01, corresponding values for postoperative BCVA were 0.24±0.17 and 0.44±0.22 logMAR (P=0.041, respectively. Average postoperative SE was comparable in the IC-ACIOL and SFPCIOL groups at 0.6±1.03 and 0.56±1.23 diopters, respectively (P=0.290. However, 10 (83.3% IC-ACIOL eyes versus 6 (46.1% SF-PCIOL eyes had SE within 1 diopter of emmetropia (P=0.048. Mean postoperative increase in CCT was comaparble between the study groups (P=0.126. Conclusion: In the absence of sufficient capsular support, the use of an IC-ACIOL for correction of aphakia during PPV can be a good alternative and seems to entail better visual outcomes as compared to SF-PCIOL.

  16. Densiron® 68 as an intraocular tamponade for complex inferior retinal detachments

    Directory of Open Access Journals (Sweden)

    Hussain RN

    2011-05-01

    Full Text Available Rumana N Hussain, Somnath BanerjeeLeicester Royal Infirmary, Leicester, UKIntroduction: Densiron® 68 is a high-density liquid used to tamponade inferior retinal detachments. We present a case series of 12 patients treated with Densiron as an intraocular tamponade agent.Methods: A retrospective analysis of 12 eyes in 12 patients was carried out. The primary endpoint was anatomic reattachment of the retina following removal of Densiron oil.Results: All patients had inferior detachments; 33% had associated proliferative vitreoretinopathy (PVR. Densiron was utilized as a primary agent in five patients (42%; the remaining patients had prior unsuccessful surgery for retinal reattachment, including pars plana vitrectomy, cryotherapy, laser, encirclement, gas (C3F8 or C2F6, or silicone oil. Eleven patients (91% had successful reattachment of the retina at 3 months following removal of Densiron; one patient had extensive PVR, total retinal detachment, preretinal macula fibrosis, and chronic hypotony, and surgical intervention was unsuccessful. Six patients (50% had raised intraocular pressure (IOP, resolving in the majority of cases following Densiron removal; two patients had long-term raised IOP requiring topical or surgical therapy. Of the six phakic patients, 50% developed significant cataract in the operated eye. Of those with successful retinal reattachment, visual outcome was variable, with 36% patients gaining two to four lines on Snellen, 27% remaining objectively the same, and 36% losing one to two lines.Conclusion: The anatomic success rate is high (91% in patients requiring Densiron tamponade for inferior retinal detachments with or without evidence of PVR either as a primary or secondary intervention. A common complication is raised IOP; however, this most often resolves following removal of the oil.Keywords: intraocular tamponade, silicone oil, retinal detachment, retinal reattachments

  17. Primary Posterior Chamber Intraocular Lens Implantation in Traumatic Cataract With Posterior Capsule Breaks

    Institute of Scientific and Technical Information of China (English)

    YupingZou; WenhuiYang

    1995-01-01

    Background:In patients with incomplete posterior capsule support,posterior chamber intraocular lenses(PC-IOLs)were implanted with both haptics transs-cleral fixation.This causes more damage to the eye and may result in more com-plications,In patients with small posterior breaks,non-fixation or single haptic fixation may be adequate.Methods:Thiry-two consecutive patients of traumatic cataract with posterior capsule breaks caused by penetrating eye trauma were retospected.Posterior chamber intraocular lenses were implanted in all these patients with three tech-niques,ie,without fixation,with single haptic fixation and with both haptics fixation .The selection of the technique was based on the position and size of the posterior capsule.The follow-up period was 21days to 28months(mean,15.2months).Results:Intra-operative problems included ciliary body bleeding(Two patents,6.25%)and enlargement of posterior capsule breaks(2patients,6.25).Postoperative visual acuity was0.5or better(Corrected)in28case(87.5%)and 0.1-0.4in four patients(12.5%),Postoperative complications included hyphema(6eyes,18.8%),transient intraocular pressure elevation(6eyes,18.8%),transient hypotention(7eyes,21.8%).Postoperative IOL position were good except one case of IOL tilt.No pupillary capture or endophthalmitis was found.Conclusions:Not all PC-IOLs have to be fixed by two haptics.In patients with small posterior capsule breaks,PC-IOLmay not be fixed or fixed by only one haptics.Eye Science1995;11:140-142.

  18. Treatment of cytomegalovirus retinitis with an intraocular sustained-release ganciclovir implant

    Directory of Open Access Journals (Sweden)

    Muccioli C.

    2000-01-01

    Full Text Available The objective of this prospective study was to evaluate the efficacy and complications of the use of an intraocular sustained-release ganciclovir implant for the treatment of active cytomegalovirus (CMV retinitis in AIDS patients. Thirty-nine eyes of 26 patients were submitted to ocular surgery. All patients underwent complete ocular examination before and after surgery. The surgical procedure was always done under local anesthesia using the same technique. The mean time for the surgical procedure was 20 min (range, 15 to 30 min. The average follow-up period was 3.7 months. Of all patient, only 4 presented recurrence of retinitis after 8, 8, 9 and 2 months, respectively. Three of them received a successful second implant. All 39 eyes of the 26 patients presented healing of retinitis as shown by clinical improvement evaluated by indirect binocular ophthalmoscopy and retinography. Retinitis healed within a period of 4 to 6 weeks in all patients, with clinical regression signs from the third week on. Six (15.4% eyes developed retinal detachment. None of the patients developed CMV retinitis in the contralateral eye. The intraocular implant proved to be effective in controlling the progression of retinitis for a period of up to 8 months even in patients for whom systemic therapy with either ganciclovir or foscarnet or both had failed. The intraocular sustained-release ganciclovir implant proved to be a safe new procedure for the treatment of CMV retinitis, avoiding the systemic side effects caused by the intravenous medications and improving the quality of life of the patients.

  19. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  20. Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gibbons A

    2016-10-01

    Full Text Available Allister Gibbons, Tayyeba K Ali, Daniel P Waren, Kendall E Donaldson Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA Purpose: The purpose of this study was to assess the causes and possible solutions for patient dissatisfaction after the implantation of presbyopia-correcting intraocular lenses (IOLs. Methods: This study was a retrospective review of clinical records. All patients who were seen between January 2009 and December 2013 whose primary reason for consultation was dissatisfaction with visual performance after presbyopia-correcting IOL implantation were included in the study. A single treating physician, who determined the most probable cause of dissatisfaction, decided which interventions to pursue following the initial consultation. Results: Data from 74 eyes of 49 patients were analyzed. The most common cause for complaint was blurry or foggy vision both for distance and near (68%. Complaints were most frequently attributed to residual refractive error (57% and dry eye (35%. The most common interventions pursued were treatment of refractive error with glasses or contact lenses (46% and treatment for dry eye (24%. Corneal laser vision correction was done in 8% of eyes; 7% required an IOL exchange. After the interventions, 45% of patients had completed resolution of symptoms, 23% of patients were partially satisfied with the results, and 32% remained completely dissatisfied with the final results. Conclusion: The most identifiable causes of dissatisfaction after presbyopia-correcting IOL implantation are residual refractive error and dry eye. Most patients can be managed with conservative treatment, though a significant number of patients remained unsatisfied despite multiple measures. Keywords: intraocular lens, cataract, presbyopia, multifocal intraocular lens

  1. Toric markers-assisted implantation of the scleral-fixated intraocular lens

    Science.gov (United States)

    Song, Hu-Ping; Tian, Bing-Yu; Peng, Jing

    2016-01-01

    AIM To evaluate the efficacy of toric intraocular lens markers-assisted implantation of the scleral-fixated intraocular lens (SFIOL). METHODS From October 2010 to December 2013, all patients who had undergone secondary SFIOL implantation were assigned to group 1 and 2, in group 1 SFIOL was performed with the assist of radial keratotomy (RK)-marker, and in group 2 SFIOL was performed with the assisted of toric intraocular lens markers (T-and axis markers). Patients' demographic data and information on baseline preoperative visual acuity, indication for surgery and latest postoperative visual acuity were collected and analyzed. The haptic and optic positions were determined by ultrasound biomicroscopy. The optic tilt angle and decentration distance were measured. RESULTS The study evaluated 43 eyes of 43 patients ranging in age from 3 to 66y. Group 1 comprised 24 eyes (24 patients) and group 2, 19 eyes (19 patients). Uncorrected reoperative acuity was improved on all the eyes postoperatively. The improved postoperative acuity was significantly more in group 2 than that in group 1 (1.11±0.38 vs 0.82±0.45 logMAR; F=4.85, P=0.03). Ultrasonic biomicrograph examination showed that the rate of haptic asymmetry was significantly higher in group 1 (42%, 10/24) than that in group 2 (11%; 2/19) (Chi square=3.68, P=0.04). The mean tilted degree in group 1 was significantly higher than that in group 2 (P=0.04). Mean decentration distance in group 1 was greater than that in group 2 (P=0.03). CONCLUSION During SFIOL the toric markers help the surgeon identify the placement of fixation more precisely than that with the use of RK marker. PMID:27672593

  2. Intra-operative assessment of toric intra-ocular lens implantation

    Directory of Open Access Journals (Sweden)

    Tsinopoulos Ioannis

    2011-01-01

    Full Text Available We report a new procedure for intra-operative toric intra-ocular lens (IOL axis assessment in order to achieve optimal implantation. IOL implantation procedure was directly recorded. An assessor estimated the angle formed by the marked 0-180 axis and the toric IOL axis after implantation with the use of the appropriate software. If IOL implantation was assessed to be inaccurate, the surgeon was advised to correct IOL positioning by rotating the IOL clockwise. The assessment procedure was repeated until accurate IOL positioning was achieved.

  3. A slide rule for calculating the power of an intraocular lens.

    Science.gov (United States)

    Wang, G J; Pomerantzeff, O; Miao, T Y

    1983-01-01

    We have designed a slide rule to calculate the emmetropizing and iseikonizing power of an intraocular lens (IOL). Like the dial biometer currently used for these calculations, the slide rule is inexpensive, easy to use, simple, and a compact pocket size. It can, however, also be used to calculate postoperative refractive error, corneal power when various keratometers are used, and conversion of refractive correction at the spectacle frame to that at the cornea, or vice versa. All the calculated data are within the accuracy suitable for clinical work. PMID:6630016

  4. Innovative confocal laser method for exact dioptric power measurement of intraocular lens implants Invited Paper

    Institute of Scientific and Technical Information of China (English)

    Ilko K. Ilev; Robert W. Faaland; Do-Hyun Kim; Robert H. James; Don Calogero

    2008-01-01

    We present a novel confocal laser method (CLM) for precise testing of the dioptric power of both positive and negative intraocular lens (IOL) implants. The CLM principle is based on a simple fiber-optic confocal laser design including a single-mode fiber coupler that serves simultaneously as a point light source used for formation of a collimated Gaussian laser beam, and as a highly sensitive confocal point receiver. The CLM approach provides an accurate, repeatable, objective, and fast method for IOL dioptric power measurement over the range from 0 D to greater than =t=30 D under both dry and in-situ simulated conditions.

  5. Pars plana cicatrization of sewn-in posterior chamber intraocular lens haptics.

    Science.gov (United States)

    McDermott, M L; Puklin, J E

    1997-03-01

    The authors describe the unexpected finding of cicatrization of posterior chamber lens haptics to the pars plana. This was found during removal of a secondary, transscleral sewn-in pseudophakos during a retinal reattachment procedure. Ophthalmic history and intraoperative photography revealed pars plana cicatrization of haptics. Despite removal of trans-scleral prolene fixation sutures and application of gentle traction, the posterior chamber lens haptics remained firmly adherent to pars plana retina. The haptics were amputated to prevent significant chorioretinal damage. The conventional belief that all sewn-in posterior chamber intraocular lenses cause little or no scarring response around the haptics may be unfounded.

  6. Influence of various anesthetic drugs on the intraocular pressure of cats.

    Science.gov (United States)

    Hahnenberger, R W

    1976-04-14

    Cats with one normal eye and one eye with experimental glaucoma were trained to tolerate tonometry while conscious. They were then given the general anesthetic agents pentobarbital, ketamine, and CI-744 in the lowest and twice the lowest dosages which permitted tonometry in untrained cats. Pentobarbital lowered intraocular pressure (IOP) by 20-50%. Ketamine raised IOP by about 10%. CI-744 had essentially no effect on IOP. The two conpoments of CI-744, tiletamine (CI-634) and zolazepam (CI-716) were given individually in the doses in which they had been given as part of CI-744. Tiletamine had no effect on IOP, while zolazepam lowered IOP by about 10%. PMID:1083696

  7. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  8. Twenty-four-hour intraocular pressure patterns in a symptomatic patient after ab interno trabeculotomy surgery

    Directory of Open Access Journals (Sweden)

    Mansouri K

    2014-11-01

    Full Text Available Kaweh Mansouri,1 Felipe A Medeiros,2 Robert N Weinreb2 1Glaucoma Sector, Department of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland; 2Hamilton Glaucoma Center and Department of Ophthalmology, University of California, San Diego, La Jolla, CA, USA Abstract: We report the results of repeated ambulatory continuous 24-hour intraocular pressure (IOP monitoring with a contact lens sensor (CLS in a glaucoma patient with ocular pain after ab interno trabeculotomy (Trabectome™ surgery. Our findings show that a combined prostaglandin–pilocarpine treatment reduced nighttime IOP peaks and relieved the patient’s symptoms. Keywords: 24-hour, Trabectome contact lens sensor, prostaglandin–pilocarpine treatment

  9. Using the Electroretinogram to Understand How Intraocular Pressure Elevation Affects the Rat Retina

    Directory of Open Access Journals (Sweden)

    Bang V. Bui

    2013-01-01

    Full Text Available Intraocular pressure (IOP elevation is a key risk factor for glaucoma. Our understanding of the effect that IOP elevation has on the eye has been greatly enhanced by the application of the electroretinogram (ERG. In this paper, we describe how the ERG in the rodent eye is affected by changes in IOP magnitude, duration, and number of spikes. We consider how the variables of blood pressure and age can modify the effect of IOP elevation on the ERG. Finally, we contrast the effects that acute and chronic IOP elevation can have on the rodent ERG.

  10. Effect of pegaptanib sodium 0.3 mg intravitreal injections (Macugen) in intraocular pressure

    DEFF Research Database (Denmark)

    Boyer, David S; Goldbaum, Mauro; Leys, Anita M;

    2014-01-01

    OBJECTIVE: To assess the rate of pegaptanib-associated sustained intraocular pressure (IOP) elevation. METHODS: A posthoc analysis was conducted on all IOP measurements, except the immediate 30-min postinjection, from all subjects randomised to pegaptanib 0.3 mg or sham injections continuously in...... lowering medication added during the course of the study. No subject required glaucoma surgery. CONCLUSIONS: In V.I.S.I.O.N., after 2 years, there was no evidence of sustained IOP elevation associated with pegaptanib 0.3 mg use. TRIAL REGISTRATION NUMBER: NCT00321997....

  11. The Comprehensive Control of Astigmatism during and Following Intraocular Lens Implantation.

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    The operating corneoloscope and Terry operative keratometer were used respectively in 29 and 34 eyes during the intraocular lens implantation to measure the corneal astigmatism qualitatively or quantitatively,so that the tension of incision closure could be adjusted. The surgically induced astigmatism in qualitative group two weeks after the operation was 3. 5 ± 1. 70 D and that in quantitative group was 2. 56±1. 60 D. There were 55.17% and 38. 24% of the eyes with over 2. 00 D corneal astigmatism in qu...

  12. The Clinical Analysis of Secondary Glaucoma Following Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    We present 14 patients with secondary gluacoma following the implantation of a posterior chamber intraocular lens (lOLs). All patients were u-nilateral gluacoma , which developed within 1 month following the IOL implantation in 10 cases, and from 1 to 3 years in 4 cases. The angle of anterior chamber was open in 8 patients, and close in 6 ones. Seven patients required treatment of antiglaucomatous medicine; 4 patients underwent laser indecto-my and 3 patients required antiglaucoma surgery. The results s...

  13. Comparison of Trans-scleral Fixation of PMMA and Foldable Intraocular Lens in Children

    Institute of Scientific and Technical Information of China (English)

    Yuping Zou; Zhende Lin; Bo Feng; Shaozhen Li

    2001-01-01

    Purpose: To observe the difference of the effects of PMMA and foldable intraocular lenses (IOLs) trans-sclerally fixed in pediatric eyes. Methods: Thirty-two children (43 eyes) who had undergone trans-scleral fixation of IOL were retrospected, of whom 5 children were implanted PMMA IOL in both eyes, 6children were implanted PMMA IOL in one eye and foldable IOL in the other eye, 12children were implanted foldable IOL in one eye and 9 chilrden were implanted PMMA IOL in one eye. Mean age was 5.3 years ( range 2.5 ~ 12 years ). Twelve children had traumatic cataract and the others congenital cataract before lens extraction. Results: Foldable group (18 eyes ): Mean follow-up was 12.1 months. Visual acuity (VA): compared with the best corrected VA before IOL fixation, postoperative best corrected VA improved in 16 eyes, remained unchanged in 2 eyes. In 14 eyes, one or two stitches were needed to seal the incision. Complications: Severe anterior chamber reaction was seen in 3 eyes. Intraocular bleeding was found in 3 eyes. IOL decentration was detected in 1 eye. Iris capture of IOL was seen in one eye. PMMA group (25 eyes ):Mean follow-up was 20.3 months. Visual acuity (VA): compared with the best corrected VA before IOL fixation, postoperative best corrected VA improved in 19 eyes,remained unchanged in 5 eyes and got worse in one eye. In 24 eyes, one to three stitches were needed to seal the incision. Complications: Severe anterior chamber reaction was seen in 5 eyes. Intraocular bleeding was found in 4 eyes. IOL decentration was seen in one eye. Iris capture of IOL was seen in 3 eyes. Intraocular pressure elevated in one eye. Conclusion: Our study shows that trans-scleral fixation of IOL is a safe procedure in pediatric eyes. Foldable IOL showed similar effect compared with PMMA IOL in pediatric trans-scleral fixation. Eye Science 2001; 17:61 ~ 64.

  14. An investigation on dysphotopsia of a sigma-edged intraocular lens

    Institute of Scientific and Technical Information of China (English)

    Zhishan Gao; Meimei Kong; Xinhua Li; Lei Chen; Rihong Zhu

    2006-01-01

    @@ A sigma-edged design of intraocular lens (IOL) is proposed to minimize the reflected glare images associated with the edge. The optimal sigma inverse edge is investigated when pupil diameter is 5.0 mm by the established Escudero-Sanz's wide angle model. The non-sequential ray tracing program of Zemax-EE (Zemax Development Corp., San Diego, USA) is used to investigate the sigma edge of reducing the potential for edge glare phenomena. The results show that sigma-edged design can significantly reduce the reflected glare intensity on retina if the angle of its inverse edge is taken from 20 to 70 degrees.

  15. A Rapid and Convenient Procedure to Evaluate Optical Performance of Intraocular Lenses

    OpenAIRE

    Frank Schaeffel; Hakan Kaymak

    2014-01-01

    A new portable lens scanner was developed and tested for measuring focal lengths and relative contrast transfer of mono- and multifocal intraocular lenses (IOLs). A photograph of a natural scene was imaged in white light through an IOL in a water-filled cuvette, with their +21D base power largely neutralized by a −20D trial lens, using a USB monochrome video camera that could be focused via a laptop-controlled stepping motor from −8.5 to + 8.0D. The output of 10000 ON-OFF antagonistic “recept...

  16. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno; Neto, Eliana

    2016-01-01

    Objective To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL) in ectopia lentis in Marfan syndrome (MFS). Design Retrospective study. Methods Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA), and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years). Results The average follow-up period was 6.66 months (range: 4–16 months). Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was −0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg) and 16 mmHg (range: 12–18 mmHg), respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit) and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm), as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that underwent lensectomy and retropupillary ICIOL implantation have had excellent visual outcomes with no complications so far. PMID:27382335

  17. Fungal endophthalmitis caused by Paecilomyces variotii, in an immunocompetent patient, following intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Anita K

    2010-01-01

    Full Text Available We report the case of a 70-year-old man who was admitted for anterior endophthalmitis following an intraocular lens implantation. He had developed a fluffy growth resembling a fungal mass on the iris of the right eye. The mass was removed and sent for fungal studies to our department. Direct microscopy revealed hyphae. Further studies helped identify the fungus to belong to genus Paecilomyces. This is a rare case of fungal endophthalmitis caused by Paecilomyces variotii in an immunocompetent person.

  18. Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Lucien A. M. van Philips

    2011-01-01

    Full Text Available Toxic anterior segment syndrome (TASS developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL. Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterilization and cleaning of surgical instruments to the possibility of endotoxines in ophthalmic viscosurgical devices (OVD. These rare cases should alert the surgeon to the possibility of TASS after pIOL implantation.

  19. Experimentally observe the effect of spherical aberration on diffractive intraocular lens using adaptive optics

    Science.gov (United States)

    Guo, Huanqing; DeLestrange, Elie

    2015-03-01

    We first investigated the similarity in optical quality of a batch of diffractive intraocular lenses (DIOLs), providing experimental evidence for one DIOL as representative of a batch. Using adaptive optics, we then evaluated one DIOL under different levels of Zernike spherical aberration (SA) by applying both a point spread function test and a psychophysical visual acuity test. We found that for small aperture size SA has the effect of shifting the through-focus curve of DIOL. Also, for a relatively large aperture size, it has different effects on the distant and near foci.

  20. Measurement of intraocular distances in human eyes by using Fourier domain low-coherence interferometry

    Science.gov (United States)

    Feng, Liang; Zhu, Lida; Li, Qinghua; Ma, Zhenhe; Wang, Bo; Wang, Yi

    2016-03-01

    We introduce a system for rapidly measuring the intraocular distances of human eyes in vivo with high sensitivity by using Fourier domain low-coherence interferometry. The system mainly consisting of a rapid focus displacement unit and a reference arm which has a variable optical path length. This system is capable of providing a complete biometrical assessment of a human eye in a single measurement procedure, including cornea thickness, anterior chamber depth, lens thickness, and axial length. The system is experimentally verified by measuring the four parameters of a human eye in vivo.

  1. A time-delay calibrated method for cornea hysteresis and intraocular pressure measurement

    Science.gov (United States)

    Wang, Kuo-Jen; Tsai, Che-Liang; Wang, Wai; Hsu, Long; Hsu, Ken-Yuh

    2016-04-01

    The presence of cornea hysteresis (CH) in characterizing the intraocular pressure (IOP) of a human eye deteriorates the accuracy of IOP. To suppress CH, the pressure gauge of a tonometer must be located as close as possible to the cornea. However, this arrangement is unpractical because appropriate working distance to the cornea is required. In this paper, a time-delay calibrated (TDC) method is proposed to counteract the undesired effect of CH in characterizing the IOP. Employing this TDC method, the CH approaches to zero for most eyes measured.

  2. Design, synthesis, and evaluation of NO-donor containing carbonic anhydrase inhibitors to lower intraocular pressure.

    Science.gov (United States)

    Huang, Qinhua; Rui, Eugene Y; Cobbs, Morena; Dinh, Dac M; Gukasyan, Hovhannes J; Lafontaine, Jennifer A; Mehta, Saurabh; Patterson, Brian D; Rewolinski, David A; Richardson, Paul F; Edwards, Martin P

    2015-03-26

    The antiglaucoma drugs dorzolamide (1) and brinzolamide (2) lower intraocular pressure (IOP) by inhibiting the carbonic anhydrase (CA) enzyme to reduce aqueous humor production. The introduction of a nitric oxide (NO) donor into the alkyl side chain of dorzolamide (1) and brinzolamide (2) has led to the discovery of NO-dorzolamide 3a and NO-brinzolamide 4a, which could lower IOP through two mechanisms: CA inhibition to decrease aqueous humor secretion (reduce inflow) and NO release to increase aqueous humor drainage (increase outflow). Compounds 3a and 4a have shown improved efficacy of lowering IOP in both rabbits and monkeys compared to brinzolamide (2). PMID:25728019

  3. Additive Effect of Brinzolamide on Diurnal Changes in Intraocular Pressure in Latanoprost-treated Eyes

    OpenAIRE

    Abe, Keitetsu; Kashiwagi, Kenji

    2008-01-01

    To investigate the effect of brinzolamide on diurnal fluctuations in the intraocular pressure (IOP) in patients on latanoprost ophthalmic solution prospectively was aimed. Eleven patients with primary open angle glaucoma were enrolled in this study. The subjects were admitted to the hospital and had their IOPs measured over 24 hours (10 AM, noon, 2 PM, 4 PM, 6 PM, 8 PM, 10 PM, midnight, 3 AM, 6 AM, and 8AM). After topical administration of brinzolamide twice daily for 4-8 weeks for one eye, t...

  4. Genome-wide association study of intraocular pressure identifies the GLCCI1/ICA1 region as a glaucoma susceptibility locus.

    OpenAIRE

    Blue Mountains Eye Study (BMES); Wellcome Trust Case Control Consortium; Strange, A; Bellenguez, C; Freeman, C.; Pirinen, M.; Su, Z.; Band, G.; Pearson, R; Vukcevic, D.; Rautanen, A; Spencer, CC; Donnelly, P

    2013-01-01

    To discover quantitative trait loci for intraocular pressure, a major risk factor for glaucoma and the only modifiable one, we performed a genome-wide association study on a discovery cohort of 2175 individuals from Sydney, Australia. We found a novel association between intraocular pressure and a common variant at 7p21 near to GLCCI1 and ICA1. The findings in this region were confirmed through two UK replication cohorts totalling 4866 individuals (rs59072263, P(combined) = 1.10 × 10(-8)). A ...

  5. Prevention of postoperative infections in ophthalmic surgery

    Directory of Open Access Journals (Sweden)

    Ram Jagat

    2001-01-01

    Full Text Available Postoperative endophthalmitis is a serious, vision-threatening complication of intraocular surgery. Better instrumentation, surgical techniques, prophylactic antibiotics and better understanding of asepsis have significantly reduced the incidence of this complication. Postoperative endophthalmitis may occur as an isolated event or as a cluster infection. Topical antibiotics, preoperative periocular preparation with povidone-iodine combined with a sterile operating room protocol significantly reduce the incidence of isolated postoperative endophthalmitis. The role of antibiotics in the irrigating fluid and subconjunctival antibiotics remains controversial. Cluster infections on the other hand are more likely to occur due to the use of contaminated fluids/viscoelastics or a breach in operating room asepsis. Prevention of postoperative endophthalmitis requires strict adherence to operating room norms, with all involved personnel discharging their assigned roles faithfully.

  6. The Relation of the Location of Haptics of Posterior Chamber Intraocular Lenses and Peripheral Anterior Synechia

    Institute of Scientific and Technical Information of China (English)

    RuiduanLiao; ShaozhenLi

    1995-01-01

    Purpose:To investigate the occurrence,outcome and influencial factors of the pe-ripheral anterior synechia(PAS)following implantation of posterior chamber in-traocular lenses for finding a way to reduce thePAS.Subjects;40 eyes of 38senile cataract patients with normal chamber angle and in-traocular pressue(IOP)preoperatively were examined.Methods:Extracapsular cataract extraction was performed under microscope with insertion of a posterior chamber lens implant vaulted anteriorly by 10°.Go-nioscopy and slit-lamp examination and photography of the operated eyes were performed 3to 6months postoperatively.Results:PAS were found in 20(50%)of the 40eyes.Among the 20eyes with PAS the locations of 23haptics in17eyes corresponded with those of the PAS.PAS were seen more frequently with vertically sulcus-fixated haptics than with the horizontally capsular-fixated haptics.showing a significant difference(P<0.05).88%of the eyes withPAS had pupillary edformation,but their visual acuities and IOP were not affected.Conclusions:PAS is more likely to occur with vertically sulcus-fixated IOL.Rotat-ing the capsular-fixated haptics to the horizontal position may reduce the inci-dence of PAS.Gonioscopy should be a routine follow-up examination.

  7. Intraocular pressure determination in clinically normal red-footed tortoise (Geochelone carbonaria).

    Science.gov (United States)

    Selmi, André L; Mendes, Guilherme M; McManus, Concepta; Arrais, Patrícia

    2002-03-01

    Intraocular pressure (IOP) reflects a balance between aqueous humor production and outflow and is often an essential ophthalmic diagnostic procedure in animals. The objective of this study was to estimate IOP in clinically normal red-footed tortoises (Geochelone carbonaria) of various sizes by using applanation tonometry. Intraocular pressures were estimated for 25 captive red-footed tortoises (10 males, 10 females, and 5 animals of unknown sex) by using an applanation tonometer after topical anesthesia. Body length ranged from 5.1 to 54.9 cm, measured from nuchal to anal scutes. Five measurements from each eye were obtained by a single observer in an ambient temperature of approximately 30 degrees C. Observer's reliability was good (intraclass r = 0.75), and IOP did not change over the ordered sequence of five replicate measurements. For individual tortoises the correlation for IOP between the left and right eyes was low (r = 0.20). The paired t-test did not show any statistical effect (P = 0.426) for the difference in IOP between the left and right eyes. Mean IOP determined for 10 confirmed males and 10 confirmed females did not differ between sexes (P = 0.244). The mean IOP of five small tortoises ( 10 cm long). In red-footed tortoises there does not appear to be any relation between carapace length and IOP. PMID:12216794

  8. Laser flare photometry: a noninvasive, objective, and quantitative method to measure intraocular inflammation.

    Science.gov (United States)

    Tugal-Tutkun, Ilknur; Herbort, Carl P

    2010-10-01

    Aqueous flare and cells are the two inflammatory parameters of anterior chamber inflammation resulting from disruption of the blood-ocular barriers. When examined with the slit lamp, measurement of intraocular inflammation remains subjective with considerable intra- and interobserver variations. Laser flare cell photometry is an objective quantitative method that enables accurate measurement of these parameters with very high reproducibility. Laser flare photometry allows detection of subclinical alterations in the blood-ocular barriers, identifying subtle pathological changes that could not have been recorded otherwise. With the use of this method, it has been possible to compare the effect of different surgical techniques, surgical adjuncts, and anti-inflammatory medications on intraocular inflammation. Clinical studies of uveitis patients have shown that flare measurements by laser flare photometry allowed precise monitoring of well-defined uveitic entities and prediction of disease relapse. Relationships of laser flare photometry values with complications of uveitis and visual loss further indicate that flare measurement by laser flare photometry should be included in the routine follow-up of patients with uveitis. PMID:19430730

  9. Transconjunctival sutureless intrascleral intraocular lens fixation using intrascleral tunnels guided with catheter and 30-gauge needles.

    Science.gov (United States)

    Takayama, Kohei; Akimoto, Masayuki; Taguchi, Hogara; Nakagawa, Satoko; Hiroi, Kano

    2015-11-01

    We invented a new method for fixing an intraocular lens (IOL) in the scleral tunnel without using a wide conjunctival incision. Modified bent catheter needles were used to penetrate the IOL haptics through the sclerotomy sites. The IOL haptics were inserted into 30-guage (G) scleral tunnels guided by double 30-G needles piercing the sclera. All procedures were performed through the conjunctiva without wide incision. The procedure does not require special forceps, trocars or fibrin glue, only catheter and 30-G needles. The aid of an assistant was not required to support the IOL haptic. The procedures were easily learnt based on our previous method. As with other transconjunctival sutureless surgeries, patients feel less discomfort and the conjunctiva can be conserved for future glaucoma surgery. Complications included two cases of vitreous haemorrhage (16.7%), and one case each of postoperative hypotony, and iris capture (8.3%). Astigmatism induced by intraocular aberration was the same as we reported previously. Our method for fixing the IOL into the scleral tunnel is innovative, less expensive, less invasive and quick. This modified method is a good alternative for fixing IOL haptics into the sclera.

  10. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    Science.gov (United States)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  11. Study on intra-ocular lens aberration measurement in-air

    Science.gov (United States)

    Wang, Yuanyuan; Chen, Jiaojie; Fen, Haihua; Hu, Chuan; Li, Yiyi

    2010-10-01

    In clinical ophthalmology, the wavefront aberration of human eyes is expressed by Zernike polynomial after cataract surgery and intraocular lens implantation, the human eyes aberration will change. The problem of objective evaluation of wavefront aberration introduced by the Intra-ocular (IOL) in-vivo remains unsolved. This paper introduced the measurement principal of IOL wavefront aberration with expression by Zernike polynominal in air. A Hartmann-Shack wavefront sensor system was constructed to measure the wavefront of IOL and to get the corresponding grid patterns. After a series of computer image processing steps, 7th order with 35 items Zernike coefficients was obtained. The IOL of 20.0D power was measured 5 times by this system to get the spherical aberration about 6.73+/-0.02μm, demonstrating the good repeatability of the system. Ten IOLs with the same 20.0D power but difference in surface curvature were chosen for measurement. The spherical aberration observed were in the range of 2.74μm-11.26μm. These results are valuable for the optical design of IOLs and the aberration analysis of human eyes post-operation.

  12. Sutureless intrascleral intraocular lens fixation with lamellar dissection of scleral tunnel

    Directory of Open Access Journals (Sweden)

    Kawaji T

    2016-01-01

    Full Text Available Takahiro Kawaji,1,2 Tomoki Sato,2 Hidenobu Tanihara11Department of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Chuo-ku, 2Sato Eye & Internal Medicine Clinic, Kumamoto, JapanPurpose: To report the results of sutureless scleral fixation of a posterior chamber intraocular lens (IOL by using our developed simple technique.Methods: We retrospectively reviewed the medical records of 48 eyes of 47 patients who underwent sutureless intrascleral IOL fixation by using our modified technique. A 25-gauge microvitreoretinal knife was used to perform sclerotomies and create limbus-parallel scleral tunnels with lamellar dissection in which the haptics were fixed.Results: The IOLs were fixed and centered well. The mean follow-up period was 26.7 months. Postoperative complications included smooth vitreous hemorrhage in four eyes (8.3%, cystoid macular edema in two eyes (4.2%, and iris capture of the IOL in two eyes (4.2%. No other complications, such as breakage of the IOL, spontaneous IOL dislocation, or retinal detachment, were detected during the follow-up period.Conclusion: The lamellar dissection of the limbus-parallel scleral tunnel can simplify the forceps-assisted introduction of the haptics into the scleral tunnel, and this technique seemed to be safe.Keywords: intraocular lenses, ophthalmologic surgical procedures, intrascleral fixation, sutureless fixation

  13. Solid Lipid Nanoparticles Improve the Diclofenac Availability in Vitreous after Intraocular Injection

    Science.gov (United States)

    Abrishami, Majid; Vakili Ahrari Roodi, Mohammad

    2016-01-01

    Purpose. In order to improve the drug availability after intravitreal administration, solid lipid nanoparticles (SLNs) containing diclofenac were prepared. Methods. In this experimental study, 18 albino rabbits were included. In right and left eyes of all rabbits, SLNs containing diclofenac and commercial form of diclofenac (0.3 mg drug) were intravitreally injected, respectively. One, four, twelve, twenty-four, and forty-eight hours after injection, vitreous and aqueous humor samples were obtained in all cases. Then, the concentration of diclofenac sodium was evaluated in all samples. Results. Size of nanoparticles was around 170 nm after preparation. Drug concentration in eyes injected with SLNs was significantly higher than left eyes injected with commercial formulation up to 4 hours after intravitreal injection (p < 0.05). Diclofenac was quantified in samples up to 48 hours after intraocular injection. Four hours after intravitreal injection, the concentration of diclofenac in vitreous and aqueous humor of eyes receiving SLNs was, respectively, 2.5 and 6.5 times higher than eyes injected with commercial form of drug. Conclusions. Here, we demonstrate the potential of SLNs as a carrier of diclofenac for intraocular injection in order to prevent the systemic effects of the drug, increase the injection intervals, and improve the patient compliance.

  14. A retrospective analysis of the first Indian experience on Artisan phakic intraocular lens

    Directory of Open Access Journals (Sweden)

    Senthil Sirisha

    2006-01-01

    Full Text Available Purpose: To evaluate the efficacy, safety, predictability and stability of implanting a polymethylmethacrylate phakic intraocular lens (PIOL in high myopia. Materials and Methods: A retrospective analysis of the data of patients who underwent Artisan phakic IOL implantation between 2002 and 2003 with a follow-up of at least 24 months. Results: An Artisan myopia lens was implanted in 60 eyes of 36 patients with preoperative myopia ranging from -5.0 to -24.0 D. Mean patient age was 22.6 years. Mean spherical equivalent of manifest refraction stabilized by the first postoperative week. At three months follow-up, 54 eyes (90% had a postoperative refraction within ± 1D emmetropia and 45 eyes (75% had uncorrected visual acuity of 20/40 or better. Seven eyes (11.6% had loss of one Snellen line and none had loss of two Snellen lines or more at three months. The mean endothelial cell loss was 3.8% at three months, 5.2% at six months, 5.25% at 12 months and 6.38% at two years, which was not significant. Postoperative complications included anterior chamber reaction in two eyes (3.3%, rise in intraocular pressure in six eyes (10% and dislocation of PIOL in two eyes (3.3%. Conclusion: Implantation of Artisan myopia lens to correct high myopia resulted in a stable and fairly predictable refractive outcome with few complications. Significant endothelial damage was not detected in two years of follow-up.

  15. Customized toric intraocular lens implantation for correction of extreme corneal astigmatism due to corneal scarring

    Directory of Open Access Journals (Sweden)

    R Bassily

    2010-03-01

    Full Text Available R Bassily, J LuckOphthalmology Department, Royal United Hospital, Combe Park, Bath, UKAbstract: A 76-year-old woman presented with decreased visual function due to cataract formation. Twenty-five years prior she developed right sided corneal ulceration that left her with 10.8 diopters (D of irregular astigmatism at 71.8° (steep axis. Her uncorrected visual acuity was 6/24 and could only ever wear a balanced lens due to the high cylindrical error. Cataract surgery was planned with a custom designed toric intraocular lens (IOL with +16.0 D sphere inserted via a wound at the steep axis of corneal astigmatism. Postoperative refraction was -0.75/+1.50 × 177° with a visual acuity of 6/9 that has remained unchanged at six-week follow-up with no IOL rotation. This case demonstrates the value of high power toric IOLs for the correction of pathological corneal astigmatism.Keywords: intraocular lens, corneal ulceration, visual acuity, scarring

  16. Iris-claw intraocular lens implantation: Anterior chamber versus retropupillary implantation

    Science.gov (United States)

    Helvacı, Sezer; Demirdüzen, Selahaddin; Öksüz, Hüseyin

    2016-01-01

    Purpose: To compare the outcomes of anterior chamber and retropupillary implantation of iris-claw Artisan intraocular lenses (IOL). Design: Prospective, randomized, single-blinded study. Patients and Methods: Forty eyes of forty aphakic patients were enrolled. Patients were randomized into two groups. Each group includes twenty patients. Group 1 received anterior chamber Artisan IOL implantation. Group 2 received retropupillary Artisan IOL implantation. Preoperative and postoperative corrected distance visual acuity (CDVA), intraocular pressure (IOP), and all complications were noted and compared at 6 months follow-up. Results: Each two groups obtained a significant improvement in CDVA (P < 0.05). Four patients in Group 1 and five patients in Group 2 had significant but nonpermanent increase at IOP values. There were one and two pupillary irregularity in Group 1 and Group 2, respectively. In one patient, a shallow and inferior located retinal detachment were encountered in anterior chamber group. Conclusions: The results were not significantly different between the two fixation techniques for iris-claw lens. The surgery procedure is dependent to surgeon experience and eye's conditions. PMID:26953023

  17. Hydrophilic Acrylic Intraocular Lens Opacification after Descemet Stripping Automated Endothelial Keratoplasty

    Science.gov (United States)

    Norouzpour, Amir; Zarei-Ghanavati, Siamak

    2016-01-01

    Purpose: To report hydrophilic acylic intraocular lens (IOL) opacification after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in an eye with multiple prior intraocular surgeries and iatrogenic aniridia. Case Report: A 34-year-old woman with history of penetrating keratoplasty (PKP) for advanced keratoconus and subsequent Urrets-Zavalia Syndrome (UZS) underwent phacoemulsification and hydrophilic acrylic IOL implantation for her cataract. In order to control post-PKP glaucoma, multiple glaucoma surgeries including two glaucoma drainage implants were performed. As the original corneal graft failed, the patient subsequently underwent re-PKP. Four years later, she underwent DSAEK for treatment of the second graft failure. Ten months after DSAEK, a double semi-circular pattern of IOL opacification was observed on the anterior surface of the IOL. The patient did not report any complaints and we decided not to exchange the IOL. Conclusion: In an eye with UZS and iatrogenic aniridia, IOL opacification may result from direct contact between the IOL surface and exogenous air. Aniridia can be a risk factor for development of IOL opacification after DSAEK. Further studies are required to confirm this hypothesis. PMID:27413506

  18. Tinea Infections

    Science.gov (United States)

    ... the body they infect. Tinea corporis is a fungal infection of the skin on the body. ("Corporis" is ... Causes & Risk Factors How did I get a fungal infection? You can get a fungal infection by touching ...

  19. Uveitis-glaucoma-hyphema syndrome caused by posterior chamber intraocular lens--a rare complication in pediatric cataract surgery.

    Science.gov (United States)

    Lin, Chun-Ju; Tan, Chau-Yi; Lin, Szu-Yuan; Jou, Jieh-Ren

    2008-01-01

    We report a case of postoperative uveitis-glaucome-hyphema (UGH) syndrome following pediatric cataract surgery due to posterior chamber intraocular lens (PC-IOL). Slit-lamp examination revealed the optic of PC-IOL migrated into anterior chamber. The PC-IOL explantation was performed and ocular inflammation subsided. PMID:19230361

  20. Genome-wide analysis of multi-ancestry cohorts identifies new loci influencing intraocular pressure and susceptibility to glaucoma

    NARCIS (Netherlands)

    P.G. Hysi (Pirro); C-Y. Cheng (Ching-Yu); H. Springelkamp (Henriët); S. MacGregor (Stuart); J.N.C. Bailey (Jessica N. Cooke); R. Wojciechowski (Robert); V. Vitart (Veronique); A. Nag (Abhishek); A.W. Hewit (Alex); R. Höhn (René); C. Venturini (Cristina); A. Mirshahi (Alireza); W.D. Ramdas (Wishal); G. Thorleifsson (Gudmar); E.N. Vithana (Eranga); C.C. Khor; A.B. Stefansson (Arni B.); J. Liao (Jie); J.L. Haines (Jonathan); N. Amin (Najaf); Y. Wang (Ying); P.S. Wild (Philipp S.); A.B. Ozel (Ayse B.); J. Li; B.W. Fleck (Brian W.); T. Zeller (Tanja); S.E. Staffieri (Sandra E.); Y.Y. Teo (Yik Ying); G. Cuellar-Partida (Gabriel); X. Luo (Xiaoyan); R.R. Allingham (R Rand); J.E. Richards (Julia); A. Senft (Andrea); L.C. Karssen (Lennart); Y. Zheng (Yingfeng); C. Bellenguez (Céline); L. Xu (Liang); O. Iglesias (Oriol); J.F. Wilson (James F); J.H. Kang (Jae H.); E.M. van Leeuwen (Elisa); V. Jonsson (Vesteinn); U. Thorsteinsdottir (Unnur); D.D.G. Despriet (Dominique); S. Ennis (Sarah); S.E. Moroi (Sayoko); N.G. Martin (Nicholas); N.M. Jansonius (Nomdo); S. Yazar (Seyhan); E.S. Tai (Shyong); P. Amouyel (Philippe); J. Kirwan (James); L.M.E. van Koolwijk (Leonieke); M.A. Hauser (Michael); F. Jonasson (Fridbert); P.J. Leo (Paul); S.J. Loomis (Stephanie J.); R. Fogarty (Rhys); F. Rivadeneira Ramirez (Fernando); L.S. Kearns (Lisa S.); K.J. Lackner (Karl); P.T.V.M. de Jong (Paulus); C.L. Simpson (Claire); C.E. Pennell (Craig); B.A. Oostra (Ben); A.G. Uitterlinden (André); S-M. Saw (Seang-Mei); A.J. Lotery (Andrew); J.E. Bailey-Wilson (Joan E.); A. Hofman (Albert); J.R. Vingerling (Hans); C. Maubaret (Cécilia); A.F.H. Pfeiffer (Andreas); R.C.W. Wolfs (Roger); H.G. Lemij (Hans); T.L. Young (Terri); L.R. Pasquale (Louis); C. Delcourt (Cécile); T.D. Spector (Timothy); C.C.W. Klaver (Caroline); K.S. Small (Kerrin); K.P. Burdon (Kathryn); J-A. Zwart (John-Anker); T.Y. Wong (Tien); A.C. Viswanathan (Ananth); D.A. Mackey (David); J.E. Craig (Jamie); J.L. Wiggs (Janey); C.M. van Duijn (Cock); C.J. Hammond (Christopher); T. Aung (Tin)

    2014-01-01

    textabstractElevated intraocular pressure (IOP) is an important risk factor in developing glaucoma, and variability in IOP might herald glaucomatous development or progression. We report the results of a genome-wide association study meta-analysis of 18 population cohorts from the International Glau

  1. Effect of altered eating habits and periods during Ramadan fasting on intraocular pressure, tear secretion, corneal and anterior chamber parameters

    NARCIS (Netherlands)

    Kerimoglu, H.; Ozturk, B.; Gunduz, K.; Bozkurt, B.; Kamis, U.; Okka, M.

    2010-01-01

    Purpose To determine whether altered eating habits and periods, especially the pre-dawn meal, during Ramadan fasting have any significant effect on intraocular pressure (IOP), tear secretion, corneal and anterior chamber parameters. Methods IOP, basal tear secretion (BTS), reflex tear secretion (RTS

  2. New approach: removal of silicone oil and trocar assisted sutureless scleral fixated intraocular lens implantation at the same session

    Institute of Scientific and Technical Information of China (English)

    Yuksel; Totan; Remzi; Karadag

    2014-01-01

    Dear Sir,Iam Dr.Remzi Karadag,from the Department of Ophthalmology,Istanbul Medeniyet University School of Medicine,Istanbul,Turkey.I write to present two case reports of removal of silicone oil and trocar assisted sutureless scleral fixated intraocular lens implantation at the same session.

  3. Travoprost with sofZia® preservative system lowered intraocular pressure of Japanese normal tension glaucoma with minimal side effects

    OpenAIRE

    Mizoue, Shiro; Nakano, Tadashi; Fuse, Nobuo; Iwase, Aiko; Matsumoto, Shun; Yoshikawa, Keiji

    2014-01-01

    Background This study aimed to evaluate the effect of travoprost with sofZia® preservative system for lowering the intraocular pressure (IOP) of Japanese normal tension glaucoma (NTG) patients. Methods In this prospective, multicenter, open-label study, Japanese NTG patients with baseline IOPs

  4. In-the-bag decentration of a hydrophilic radially asymmetric multifocal intraocular lens secondary to capsule contraction.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2013-01-01

    We report a case of in-the-bag decentration and tilt of a hydrophilic rotationally asymmetric multifocal intraocular lens (IOL) of the M Plus type secondary to capsule contraction. After uneventful surgery and follow-up for 3 months, progressive decentering and tilting of the IOL secondary to capsul

  5. Intraocular degradation behavior of crosslinked and linear poly(trimethylene carbonate) and poly(D,L-lactic acid)

    NARCIS (Netherlands)

    Jansen, Janine; Koopmans, Steven A.; Los, Leonoor I.; van der Worp, Roelofje J.; Podt, Johanna G.; Hooymans, Johanna M. M.; Feijen, Jan; Grijpma, Dirk W.

    2011-01-01

    The intraocular degradation behavior of poly(trimethylene carbonate) (PTMC) networks and poly(-D,L-lactic acid) (PDLLA) networks and of linear high molecular weight PTMC and PDLLA was evaluated. PTMC is known to degrade by enzymatic surface erosion in vivo, whereas PDLLA degrades by hydrolytic bulk

  6. 新型多焦点人工晶状体临床应用的研究进展%Clinical application of new types of multifocal intraocular lens

    Institute of Scientific and Technical Information of China (English)

    张景尚; 万修华

    2015-01-01

    近年来新型多焦点人工晶状体(IOL)如非球面多焦点IOL、Toric多焦点IOL和非球面Toric多焦点IOL等的不断问世及临床应用,更好地改善了白内障患者术后的生活视力、工作视力以及生存质量.对于新型多焦点IOL的适应证应严格掌握,以使患者术后获得最佳效果.%In recent years new types of multifocal intraocular lens have been developed,such as aspheric multifocal intraocular lens,Toric multifocal intraocular lens and aspheric Toric multifocal intraocular lens and so on.The vision in life and work and the quality of life in patients with cataract were significantly improved after phacoemulsification with the new types of multifocal intraocular lens.At the same time there should be a strict indications for the new types of multifocal intraocular lens,so as to make the cataract patients implanted multifocal intraocular lens getting the best visual quality.

  7. Remifentanil-Ketamine versus Fentanyl-Ketamine sedation in patients undergoing phacoemulsification with topical anesthesia: comparison of intraocular pressure changes and sedation quality

    Directory of Open Access Journals (Sweden)

    Bahram Soleymani

    2008-04-01

    Full Text Available BACKGROUND: Narcotics and sedatives can reduce intraocular pressure. This study was performed to evaluate the effect of remifentanil plus ketamine on intraocular pressure and sedation quality in comparison with fentanyl plus ketamine during and after operation in patients undergoing phacoemulsification with topical anesthesia.METHODS: Forty four patients were randomized into two groups to receive either a continuous infusion of remifentanil (0.2 µg/kg/min for 4 min and then 0.1 µg/kg/min: Group R, n=22 or bolus intravenous fentanyl (1.5 µg/kg: Group F, n=22 for sedation. Patients in both groups received low dose ketamine (0.15 mg/kg intravenously. Topical anesthesia was performed using tetracaine 0.5% eye drop in both eyes. Intraocular pressure was measured in non-operative eye before sedation (baseline, 2 minutes after sedation, before intraocular lens insertion, at the end of operation and 15 minutes after the end of operation using Schiötz tonometer. Sedation, cooperation, satisfaction and pain scores and also postoperative nausea and vomiting were recorded in all patients. Surgeon satisfaction scores were evaluated at the end of operation.RESULTS: The intraocular pressure did not differ significantly between the two groups throughout the study. The mean (SD intraocular pressures 2 minutes after sedation, before intraocular lens insertion, at the end of operation and 15 minutes after the end of operation in recovery room were all less than that of baseline in both groups, but the baseline value was decreased only significantly (P CONCLUSIONS: Combination of remifentanil infusion and intravenous ketamine did not offer any advantages over the combination of intravenous fentanyl and ketamine in order to prevent intraocular pressure rising during phacoemulsification. The lower incidence of postoperative nausea and vomiting and higher rate of appropriate sedation in fentanyl group suggested fentanyl as a more suitable medication for systemic

  8. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Potvin, Rick

    2016-01-01

    Purpose To compare the visual acuity (VA) and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL) and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye. Patients and methods Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated. Results Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (Pdashboard or grocery shelf. VA was similar between groups at viewing distances from 60 to 40 cm, corresponding to computer or reading distance. PMID:27274184

  9. Intraocular Lens Multifocality Combined with the Compensation for Corneal Spherical Aberration:A New Concept ofPresbyopia-CorrectingIntraocular Lens

    Directory of Open Access Journals (Sweden)

    Reiner Friedrich

    2012-10-01

    Full Text Available The outcomes of a prospective consecutive study aimed at evaluating the visual and refractive benefit after cataract surgery with the implantation of the aspheric diffractive multifocal intraocular lens (IOL Tecnis ZMB00 (Abbott Medical Optics are reported. A total of 31 eyes of 19 patients (age range, 40 to 81 years underwent phacoemulsification surgery with implantation of this aspheric multifocal IOL. At 6 months after surgery, postoperative spherical equivalent was within ±1.00 D in 96.8% of eyes, with 94.7% of patients presenting a postoperative binocular far LogMAR uncorrected visual acuity (UCVA of 0.1 or better. Far best-corrected distance VA improved significantly (p < 0.01, with postoperative values of 0.1 or better in 96.8% of eyes. Postoperative near UCVA was 0.10 (equivalent to J1 or better in 93.55% of eyes. Furthermore, the IOL power was found to be very poorly correlated with the postoperative far LogMAR (r = 0.13 and near UCVA (r = 0.13. In conclusion, the aspheric diffractive multifocal IOL Tecnis ZMB00 provides a restoration of the far and near visual function after phacoemulsification surgery for cataract removal or presbyopia correction, which is predictable and independent from the optical power of the implanted IOL.

  10. Effect of intravenous metoclopramide on intraocular pressure: A prospective, randomized, double-blind, placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Sudheera K

    2008-01-01

    Full Text Available Background: Prevention of rise in intraocular pressure (IOP is essential in patients undergoing surgery for perforated eye injuries. Metoclopramide, a prokinetic agent, is commonly used to hasten gastric emptying in emergency surgeries. Aim: To study the change in IOP after intravenous metoclopramide and to study the influence of metoclopramide on change in IOP after succinylcholine and tracheal intubation. Settings and Design: A randomized, double-blind, placebo-controlled study of 60 patients undergoing non-ophthalmic elective surgery. Materials and Methods: Sixty American Society of Anesthesiologists (ASA I adult patients were randomly assigned to receive normal saline (Group C or metoclopramide 10 mg (Group M 30 min before the induction of anesthesia. Thiopentone was used for induction and succinylcholine for tracheal intubation. Intraocular pressure was measured in both the eyes pre and post drug treatment and succinylcholine and tracheal intubation using Perkins applanation tonometer. Statistical Analysis: Student′s t-test and repeated measures ANOVA were used. A P value < 0.05 was considered as significant. Results: Intraocular pressure was consistently lower in Group M than in Group C after the test drug, though the difference was not statistically significant. Intraocular pressure decreased significantly after administration of thiopentone and increased significantly in Groups C and M after tracheal intubation ( P < 0.01. Intraocular pressure was comparable between the groups at all the times. Conclusions: Metoclopramide does not cause a clinically significant change in IOP nor does it influence the changes in IOP during anesthesia and tracheal intubation. Metoclopramide shows a trend towards decrease in IOP, though clinically insignificant. Therefore metoclopramide can be used to promote gastric emptying in patients with perforated eye injury.

  11. Effects of different levels of intraocular stray light on kinetic perimetry findings.

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    Full Text Available To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings.Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900 using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular stray light were induced using non-white opacity filter (WOF filters and WOFs applied to the clear plastic eye covers of the participants. The visual acuity, pupil diameter, isopter area, and kinetic sensitivity of each meridian were analyzed for each WOF density.Visual acuity deteriorated with increasing WOF densities (p < 0.01. With a visual acuity of 0.1 LogMAR units, the isopter areas for III4e, I4e, I3e, I2e, and I1e decreased by -32.7 degree2 (-0.2%, -255.7 degree2 (-2.6%, -381.2 degree2 (-6.2%, -314.8 degree2 (-12.8%, and -59.2 degree2 (-15.2%, respectively; kinetic sensitivity for those stimuli decreased by -0.1 degree (-0.1%, -0.8 degree (-1.4%, -1.6 degree (-3.7%, -2.7 degree (-9.7%, and -1.7 degree (-16.2%, respectively. The pupil diameter with each WOF density was not significantly different.Kinetic perimetry measurements with a high-intensity stimulus (i.e., III4e were unaffected by intraocular stray light. In contrast, measurements with the I4e, I3e, I2e, and I1e stimuli, especially I2e and I1e, were affected. Changes in the shape of the isopter resulting from opacity must be monitored, especially in cases of smaller and lower-intensity stimuli.

  12. Features of YAG-laser treatment of posterior capsule opacification in eyes with intraocular comorbidities ext

    Directory of Open Access Journals (Sweden)

    O. I. Borzunov

    2015-01-01

    Full Text Available Purpose: is to evaluate the effectiveness of YAG laser posterior lens capsule dissection in patients with secondary cataract with concurrent intraocular pathology. Patients and methods: retro- and prospective analysis of the results of the YAG — laser treatment of secondary cataract in the 196 eyes, including the intraocular concomitant pathology (myopia, glaucoma, age-related macular degeneration, diabetic retinopathy, retinitis pigmentosa operated retinal detachment, chronic uveitis in remission, peripheral chorioretinal degeneration. Effectiveness of treatment was evaluated by checking visual acuity and dynamics of complaints as aberration, glare, distortion in the central field of view without proper disease of the macula. Complex preoperative studies included: refractometry, visometry with correction, perimetry, tonometry, biomicroscopy, ophthalmoscopy, ultrasound examination of the eyeball (if necessary. The examination results should demonstrate convincing evidence that posterior capsular opacification is the main reason for the decrease of visual acuity. Results:, Visual acuity, at average increased from 0.4‑0.6 to 0.8‑1.0 in 50 cases after dissection, Visual acuity improved to 2‑3 lines in 66‑4–5, 24‑6‑7 lines in 74 cases. Visual acuity remains the same, but contrast sensitivity was increased in 6 cases. The IOL location after disruption was evaluated by β-scanning and biomicroscopy. In case of the initial correct IOL position in all 195 (100 % cases, there were no dislocation in the postoperative period. Complications that can be identified were single microcraters on the IOL surface in cases of its full contact with the posterior capsule. These injuries did not affect the visual functions.Conclusion: YAG -Laser dissection of secondary cataract is effective, less traumatic, and the optimal treatment of secondary cataract, including patients with concomitant intraocular pathology, and helps to avoid over

  13. Intraocular and extraocular cameras for retinal prostheses: Effects of foveation by means of visual prosthesis simulation

    Science.gov (United States)

    McIntosh, Benjamin Patrick

    Blindness due to Age-Related Macular Degeneration and Retinitis Pigmentosa is unfortunately both widespread and largely incurable. Advances in visual prostheses that can restore functional vision in those afflicted by these diseases have evolved rapidly from new areas of research in ophthalmology and biomedical engineering. This thesis is focused on further advancing the state-of-the-art of both visual prostheses and implantable biomedical devices. A novel real-time system with a high performance head-mounted display is described that enables enhanced realistic simulation of intraocular retinal prostheses. A set of visual psychophysics experiments is presented using the visual prosthesis simulator that quantify, in several ways, the benefit of foveation afforded by an eye-pointed camera (such as an eye-tracked extraocular camera or an implantable intraocular camera) as compared with a head-pointed camera. A visual search experiment demonstrates a significant improvement in the time to locate a target on a screen when using an eye-pointed camera. A reach and grasp experiment demonstrates a 20% to 70% improvement in time to grasp an object when using an eye-pointed camera, with the improvement maximized when the percept is blurred. A navigation and mobility experiment shows a 10% faster walking speed and a 50% better ability to avoid obstacles when using an eye-pointed camera. Improvements to implantable biomedical devices are also described, including the design and testing of VLSI-integrable positive mobile ion contamination sensors and humidity sensors that can validate the hermeticity of biomedical device packages encapsulated by hermetic coatings, and can provide early warning of leaks or contamination that may jeopardize the implant. The positive mobile ion contamination sensors are shown to be sensitive to externally applied contamination. A model is proposed to describe sensitivity as a function of device geometry, and verified experimentally. Guidelines are

  14. Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry Efeito das lentes intraoculares asféricas e com pigmentação amarela na campimetria azul-amarelo

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2012-10-01

    Full Text Available PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes received ultraviolet and blue light filter (yellow tinted IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD] investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.OBJETIVO: Investigar a possibilidade de efeitos na sensibilidade ao contraste e nos resultados da campimetria azul-amarelo com implante de uma lente intraocular (LIO asférica ou de pigmentação amarela. MÉTODOS: Trata-se de um estudo prospectivo, randomizado, duplo-mascarado, envolvendo 52 pacientes portadores de catarata senil bilateral, divididos em dois grupos; 25

  15. Extraction of Posterior Polar Intraocular Foreign Bodies with Sodium Hyaluronate Backsiphon Technique

    Institute of Scientific and Technical Information of China (English)

    Jiumin Yuan; Zhengyan Wang

    2005-01-01

    Purpose: To explore the new technique on the removal of posterior polar intraocular foreign bodies (IOFBs).Methods: Dint of viscoelasticity and cohesiveness of ophthalmic viscoelastics (sodium hyaluronate) was used to wrap, dissociate and suspend IOFBs. Then IOFBs were approached and backsiphoned by using self-made backsiphon syringe needles which were selected according to the size and shape of IOFBs. The IOFBs are removed with the inflow of sodium hyaluronate naturally surging into the needles.Results: Posterior polar IOFBs in 13 cases (13 eyes) were all removed successfully at one time. There were no accidental injuries or complications. The postoperative vision in 11 cases (11 eyes) was improved, unchanged in 1 case (1 eye) and decreased in 1 case ( 1 eye).Conclusions: The technique using viscoelastics to dissociate, suspend and backsiphon IOFBs during the removal of the posterior polar IOFBs can evidently decrease operative difficulty, injury and complications.

  16. Temporary marked impairment of visual acuity in a case of intraocular malignant lymphoma during radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Miyao, Yoko; Tada, Rei; Koizumi, Noriko; Yamada, Hideaki; Kinoshita, Shigeru [Kyoto Prefectural Univ. of Medicine (Japan); Ikeda, Tsunehiko

    2000-05-01

    A 56-year-old female was referred to us for blurring of both eyes since 2 years before. She had been diagnosed as chronic uveitis and responded poorly to systemic and topical corticosteroid. Her corrected visual acuity was 0.8 right and 0.5 left. Systemic studies, including magnetic resonance imaging and gadolinium scintigraphy, were negative. Vitreous biopsy led to the diagnosis of malignant lymphoma originating from the eye. Seven days after initiation of radiation at the daily doses of 2 Gy, massive subretinal infiltration developed in her right eye forming a niveau. Systemic prednisolone induced resolution of exudate with improved visual acuity to 1.0 13 days later. This cases illustrates that radiation may induce temporary aggravation of intraocular malignant lymphoma and that it may undergo resolution following systemic corticosteroid. (author)

  17. Cuerpo extraño intraocular. Presentación de un caso

    Directory of Open Access Journals (Sweden)

    Inés Zamora Galindo

    2012-05-01

    Full Text Available Los traumatismos oculares son una causa común de deficiencia visual, principalmente de ceguera monocular en el 33 al 40 % de los casos. Se presenta el caso de un paciente de 40 años y procedencia rural, que acudió a consulta de Oftalmología del Hospital General Universitario Dr. Gustavo Aldereguía Lima por presentar visión borrosa del ojo derecho, tres meses después de haber sufrido un traumatismo. Una correcta anamnesis, examen oftalmológico y métodos diagnósticos adecuados lograron la identificación de un cuerpo extraño intraocular. El paciente fue sometido a cirugía y evolucionó favorablemente; su agudeza visual mejor corregida es de 0,7 en el ojo derecho y de 1,0 en el izquierdo.

  18. Simultaneous bilensectomy and endothelial keratoplasty for angle-supported phakic intraocular lens-induced corneal decompensation

    Directory of Open Access Journals (Sweden)

    Vikas Mittal

    2011-01-01

    Full Text Available A 40-year-old lady presented with severe endothelial cell loss in both eyes 14 years after angle-supported phakic intraocular lens (AS PIOL implantation. The left eye had severe corneal edema with bullous keratopathy. The right eye had markedly reduced endothelial cell count (655 cells/mm 2 although the cornea was clear. She underwent simultaneous bilensectomy (AS PIOL explantation and phacoemulsification and Descemet′s stripping and endothelial keratoplasty (DSEK in the left eye. Explanted AS PIOL was identified as ZSAL-4 (Morcher, Stuttgart, Germany model. Corneal edema cleared completely in 2 months with a best corrected visual acuity (-2.25 D sph of 20/60. No intervention was done in the right eye. The present case illustrates that AS PIOL-induced endothelial decompensation can be effectively managed by simultaneous bilensectomy and endothelial keratoplasty.

  19. The Management of a Patient with Elevated Intraocular Pressure Resistant to Medical Treatment: Anterior Chamber Irrigation

    Directory of Open Access Journals (Sweden)

    Abdullah Beyoğlu

    2014-10-01

    Full Text Available A 7-year-old male patient was medically treated in another center for hyphema which occurred after blunt trauma to his right eye. He was admitted to our clinic when his visual acuity decreased after being discharged. Biomicroscopic examination revealed total hyphema. Intraocular pressure (IOP was 48 mm Hg in the right eye with Goldmann applanation tonometry. Since IOP could not be managed by medical therapy and there was no regression in hyphema, anterior chamber was irrigated. As in our case, it should not be forgotten that re-hemorrhage may occur in the first week of hyphema during childhood. Moreover, surgical treatment should be considered when hemorrhage does not regress with medical treatment, increased IOP persists, and when there is a risk of corneal endothelial staining (corneal blood staining. (Turk J Ophthalmol 2014; 44: 400-2

  20. Haptic Breakage after Transscleral Fixation of a Single-Piece Acrylic Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Hiroki Tanaka

    2014-07-01

    Full Text Available Purpose: To report the case of a patient with a damaged haptic of an acrylic intraocular lens (IOL after transscleral IOL fixation. Methods: This is a retrospective and descriptive case report. Results: A 40-year-old man presented with sudden visual loss in the left eye. He had undergone phacoemulsification/aspiration and IOL implantation 3 years previously and IOL repositioning with transscleral fixation 2 years before the initial visit. His visual acuity was 0.3 in the left eye due to corneal edema caused by a foreign body, i.e., the severed haptic tip of the single-piece acrylic IOL, which was surgically removed. The IOL itself was tilted and therefore explanted. The surface of the tip of the haptic suggested that the monofilament suture thread had exerted continuous force across the haptic. Conclusions: The haptics of acrylic IOLs can be damaged after transscleral fixation.

  1. Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes.

    Science.gov (United States)

    McDonnell, P J; Champion, R; Green, W R

    1987-02-01

    Of 110 eyes with posterior chamber intraocular lenses (IOLs) examined postmortem, 37% had both haptics outside of the capsular bag; 57% had one haptic in the capsular bag and the other haptic outside of the bag. Typically, these optics were decentered by 1 to 2 mm. Only six eyes (5%) had both haptics within the capsular bag. Erosion into the ciliary sulcus produced obliteration of the major arterial circle of the iris in 12 eyes (11%). The local tissue response to eroding haptics was similar for haptics composed of polypropylene and haptics composed of polymethylmethacrylate (PMMA). The authors found considerable discrepancy between the actual location of haptics and the surgeon's desired location (i.e., capsular bag or ciliary sulcus). Most of these cases were clinically successful.

  2. Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report

    Directory of Open Access Journals (Sweden)

    Haemin Kang

    2014-01-01

    Full Text Available A 57-year-old male patient visited our clinic for decreased visual acuity in the right eye for 10 days. He denied any trauma history, but recalled that the symptom developed after straining. He had undergone uncomplicated phacoemulsification and posterior chamber intraocular lens (IOL implantation in the bag of the right eye 11 years ago. The IOL was a three-piece silicone polyimide-haptics design. On slit-lamp examination, the IOL optic and proximal part of nasal fractured haptic were found in the anterior chamber. The distal part of fractured haptic was observed in the capsular bag. He underwent IOL exchange. The fracture site of the haptic was near the optic-haptic junction. This is the unique case report of a spontaneous fracture of an implanted posterior chamber polyimide IOL haptic, which implies the possibility of IOL haptic fracture in various haptic materials.

  3. Morphological Findings of Intraocular Lens with Haptics Detached from Optics Following Cataract Surgery.

    Science.gov (United States)

    Suzuki, Yukihiko; Suzuki, Kaori; Metok, Tomomi; Nakazawai, Mitsuru

    2010-03-09

    A 55-year-old woman was treated using phacoemulsification, aspiration, and intraocular lens (IOL) implantation. Three months after surgery, the optical zone of the anterior capsule was completely closed due to strong capsular contractions. As the two haptics were found to be completely detached from the optics, the IOL was subsequently extracted and morphologically examined. Although the optics and haptics of the IOL when viewed with a stereomicroscope appeared to have no marked damage on their surfaces, an ultra-structural examination showed that a portion of the acrylic optics on the detached surface was defective. We considered that the IOL haptics might have become detached from the optics due to continuous force from postoperative capsular contractions.

  4. Anterior chamber fixation of a posterior chamber intraocular lens: A novel technique

    Directory of Open Access Journals (Sweden)

    A Sahap Kükner

    2014-01-01

    Full Text Available We aimed to evaluate the implantation of a posterior chamber intraocular lens (IOL in the anterior chamber (AC with the haptics passing through two iridectomies to the posterior chamber. A total of 33 eyes of 33 patients with inadequate posterior capsular support due to either previous aphakia or posterior capsular rupture during cataract extraction were included in the study. A double iridectomy was performed on all patients using a vitrectomy probe on the midperiphery of the iris. IOLs were implanted in the AC, and the haptics were passed through the iridectomies to the posterior chamber. The mean follow-up time was 25.3 months. AC hemorrhage occurred in five patients during the iridectomy procedure. Corneal edema was detected in eight of 14 patients with primary IOL insertions. Haptic dislocation was detected in only one patient. This technique may be a good alternative to scleral-fixated IOL implantation in eyes with aphakia.

  5. Optimizing distance image quality of an aspheric multifocal intraocular lens using a comprehensive statistical design approach.

    Science.gov (United States)

    Hong, Xin; Zhang, Xiaoxiao

    2008-12-01

    The AcrySof ReSTOR intraocular lens (IOL) is a multifocal lens with state-of-the-art apodized diffractive technology, and is indicated for visual correction of aphakia secondary to removal of cataractous lenses in adult patients with/without presbyopia, who desire near, intermediate, and distance vision with increased spectacle independence. The multifocal design results in some optical contrast reduction, which may be improved by reducing spherical aberration. A novel patent-pending approach was undertaken to investigate the optical performance of aspheric lens designs. Simulated eyes using human normal distributions were corrected with different lens designs in a Monte Carlo simulation that allowed for variability in multiple surgical parameters (e.g. positioning error, biometric variation). Monte Carlo optimized results indicated that a lens spherical aberration of -0.10 microm provided optimal distance image quality.

  6. Respiratory complications associated with ketamine anesthesia for ophthalmic procedures following intraocular pressure measurement in children

    Directory of Open Access Journals (Sweden)

    Lei Wu

    2014-01-01

    Full Text Available Background: We compared respiratory complications (RCs in children who received intramuscular (IM versus intravenous (IV or no ketamine for intraocular pressure (IOP measurement to test our observation that IM ketamine is associated with higher incidence of RCs. Materials and Methods: We analyzed 149 eye examinations under anesthesia with ketamine in 27 patients and 263 non-ketamine examinations under anesthesia in 81 patients using a mixed effects logistic regression model. Results: IM ketamine was strongly associated with increased odds of RCs compared to no ketamine (odds ratio (OR: 20.23, P < 0.0001 and to IV ketamine (OR: 6.78, P = 0.02, as were higher American Society of Anesthesiologists (ASA classification (OR: 2.60, P = 0.04, and the use of volatile agents (OR: 3.32, P = 0.02. Conclusion: Further studies should be conducted to confirm our observation of increased RCs with IM ketamine.

  7. Eye models for the prediction of contrast vision in patients with new intraocular lens designs

    Science.gov (United States)

    Piers, Patricia A.; Sverker Norrby, N. E.; Mester, Ulrich

    2004-04-01

    Theoretical calculations of the polychromatic modulation transfer function (MTF) and wave-front aberration were performed with physiological eye models. These eye models have an amount of spherical aberration that is representative of a normal population of pseudophakic eyes implanted with two different types of intraocular lens (IOL) made from high-refractive-index silicone. These theoretical calculations were compared with the measured contrast sensitivity function (CSF) under mesopic lighting conditions and with wave-front aberration (obtained with a Hartmann-Shack wave-front sensor) collected from 37 patients bilaterally implanted with the same types of lens. The relationships between the ocular wave-front aberration and the MTF predicted by the eye models and the CSF and the ocular wave-front aberration measured in eyes implanted with IOLs were investigated. The predicted improvements in MTF and wave-front aberration correlated well with the improvements measured in practice. Physiological eye models are therefore useful tools for IOL design.

  8. Optical ensemble analysis of intraocular lens performance through a simulated clinical trial with ZEMAX.

    Science.gov (United States)

    Zhao, Huawei

    2009-01-01

    A ZEMAX model was constructed to simulate a clinical trial of intraocular lenses (IOLs) based on a clinically oriented Monte Carlo ensemble analysis using postoperative ocular parameters. The purpose of this model is to test the feasibility of streamlining and optimizing both the design process and the clinical testing of IOLs. This optical ensemble analysis (OEA) is also validated. Simulated pseudophakic eyes were generated by using the tolerancing and programming features of ZEMAX optical design software. OEA methodology was verified by demonstrating that the results of clinical performance simulations were consistent with previously published clinical performance data using the same types of IOLs. From these results we conclude that the OEA method can objectively simulate the potential clinical trial performance of IOLs.

  9. Intraocular lens design for treating high myopia based on individual eye model

    Science.gov (United States)

    Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong

    2007-02-01

    In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.

  10. Abnormal increase of intraocular pressure in fellow eye after severe ocular trauma

    Science.gov (United States)

    Vaajanen, Anu; Tuulonen, Anja

    2016-01-01

    Abstract Background: An ocular injury can lead to secondary glaucoma in the traumatized eye in 3% to 20% of cases. Literature on the risk of developing elevated intraocular pressure in the nontraumatized fellow eye is scant. Clinicians treating ocular traumas should also bear in mind sympathetic ophthalmia, a rare bilateral granulomatous panuveitis following accidental or surgical trauma to 1 eye. Case report: We report a case of high-pressure glaucoma of the fellow eye without any signs of uveitis. The left eye of a 24-year-old man was injured in an inadvertent movement during a free-time table-tennis match. The eye was severely crushed, leading to blindness. His right eye developed medically uncontrolled high-pressure glaucoma only 1 month after the injury. Conclusion: To the best of our knowledge, there are no previous reports of post-traumatic glaucoma in the nontraumatized eye after open-globe injury. PMID:27495058

  11. Corneal injection track: an unusual complication of intraocular lens implantation and review

    Institute of Scientific and Technical Information of China (English)

    Julie; Y.C.Lok; Alvin; L.Young

    2015-01-01

    Phacoemulsification is the main gold standard for cataract operation in the developed world together with foldable intraocular lens(IOL) implantation by injection,allowing for stable wound construction and less postoperative astigmatism. It is a safe procedure with high success rate with the advancement in machines,improvement of IOL injection systems and further maturation of surgeons’ techniques. Despite the large number of operations performed every day, foldable IOL injection leading to an intra-stromal corneal track is a very rare complication. We report a case of this unusual finding in a 70-year-old gentleman who has undergone cataract operation in November 2011 in our hospital and will review on the complications related to foldable IOL injection.

  12. Raised intraocular pressure as a potential risk factor for visual loss in Leber Hereditary Optic Neuropathy.

    Directory of Open Access Journals (Sweden)

    Anais Thouin

    Full Text Available Leber Hereditary Optic Neuropathy (LHON is an important cause of inherited mitochondrial blindness among young adults. The majority of patients carry one of three mitochondrial DNA (mtDNA point mutations: m.3460G>A, m.11778G>A and m.14484T>C, all of which affect critical complex I subunits of the mitochondrial respiratory chain. LHON is characterised by marked incomplete penetrance, clearly implying that the mtDNA mutation is insufficient on its own to trigger retinal ganglion cell dysfunction and visual loss. In this case series of three affected patients harbouring the m.11778G>A mutation, we provide evidence suggesting that raised intraocular pressure could be a risk factor triggering visual loss in at-risk LHON carriers.

  13. A Circadian and Cardiac Intraocular Pressure Sensor for Smart Implantable Lens.

    Science.gov (United States)

    Donida, Achille; Di Dato, Giuseppe; Cunzolo, Paolo; Sala, Marco; Piffaretti, Filippo; Orsatti, Paolo; Barrettino, Diego

    2015-12-01

    This paper presents a new system to measure the Intraocular Pressure (IOP) with very high accuracy (0.036 mbar) used for monitoring glaucoma. The system not only monitors the daily variation of the IOP (circadian IOP), but also allows to perform an spectral analysis of the pressure signal generated by the heartbeat (cardiac IOP). The system comprises a piezoresistive pressure sensor, an application-specific integrated circuit (ASIC) to read out the sensor data and an external reader installed on customized glasses. The ASIC readout electronics combines chopping modulation with correlated double sampling (CDS) in order to eliminate both the amplifier offset and the chopper ripple at the sampling frequency. In addition, programmable current sources are used to compensate for the atmospheric pressure ( 800-1200 mbar ) and the circadian component (± 7 mbar) thus allowing to read out the very weak cardiac signals (± 1.6 mbar) with a maximum accuracy of 0.036 mbar.

  14. Surface PEGylation of intraocular lens for PCO prevention: An in vivo evaluation.

    Science.gov (United States)

    Xu, Xu; Tang, Jun-Mei; Han, Yue-Mei; Wang, Wei; Chen, Hao; Lin, Quan-Kui

    2016-07-01

    Posterior capsular opacification (PCO) is a common complication in cataract surgery. The development of PCO is attributed to the combination of adhesion, migration, proliferation, and transdifferentiation of the residual lens epithelial cells (LEC) onto the interface of intraocular lens (IOL) material and lens posterior, in which the initial adhesion is the beginning step and plays important roles. In the present study, hydrophilic polyethylene glycol (PEG) was immobilized onto IOL surface via plasma-aided chemical grafting procedure. The attenuated total reflection - Fourier transform infrared (ATR-FTIR) and contact angle (CA) - measurements indicate the successful surface PEGylation, as well as the excellent hydrophilicity of the surfaces. Compared with pristine IOL, the PEGylation does not influent its optical property, whereas the initial adhesion of LEC is greatly inhibited. In vivo ocular implantation results show that the PEGylated IOL presents good in vivo biocompatibility, and can effectively prevent the PCO development.

  15. Pars plana vitrectomy with posterior iris claw implantation for posteriorly dislocated nucleus and intraocular lens

    Directory of Open Access Journals (Sweden)

    Kishor B Patil

    2011-01-01

    Full Text Available We evaluated the safety and efficacy of pars plana vitrectomy (PPV with primary posterior iris claw intraocular lens (IOL implantation in cases of posterior dislocation of nucleus and IOL without capsular support. This was a retrospective interventional case series. Fifteen eyes underwent PPV with primary posterior iris claw IOL implantation performed by a single vitreoretinal surgeon. The main outcome measures were changes in best corrected visual acuity and anterior and posterior segment complications. A total of 15 eyes were included in this study. Eight had nucleus drop, three had IOL drop during cataract surgery and four had traumatic posterior dislocation of lens. The final postoperative best corrected visual acuity was 20/60 or better in 11 patients. This procedure is a viable option in achieving good functional visual acuity in eyes without capsular support.

  16. Evaluation of intraocular lens implant location in the eyeball basing on the Purkinje images

    Science.gov (United States)

    Jóźwik, A.; Siedlecki, D.; Zajac, M.

    2012-01-01

    Intraocular lens (IOL) is an artificial implant substituting natural crystalline lens which is non-transparent due to cataract. Incorrect location of the IOL in the eyeball (e.g. its shift or tilt) causes significant deterioration of patient's vision. The analysis of Purkinje images (i.e. reflections from successive refracting surfaces in the eye) enables to determine the real IOL location and thus helps in evaluating the retinal image quality. The experimental setup for Purkinje images recording consists of illuminator, composed of a number of infrared LEDs, telecentric lens and detector (CCD camera). Analysis of mutual position of particular reflections enables to evaluate the lens location in respect to the corneal axis. The actual measurements are realized on artificial eye model, what allows to estimate the precision of the algorithm applied in the calculations. In the future the experimental set-up will be adapted to measure the eyes of real patients.

  17. Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2012-12-01

    Full Text Available A 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eyes was 20/20 and neither complained of visual discomfort. In conclusion, we found that a reversed-optic Tecnis multifocal IOL in the present case resulted in good final visual acuity without significant differences in aberrations compared to the other eye, and a conservative management can be taken as a safe option.

  18. Cell adhesion of F{sup +} ion implantation of intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.J. E-mail: dejunli@hotmail.com; Cui, F.Z.; Gu, H.Q

    1999-04-01

    The cell adhesion of ion implanted polymethylmethacrylate (PMMA) intraocular lens was studied using cultured cells in vitro. F{sup +} ion implantation was performed at the energies of 40, 60, 80, 100 keV with the fluences ranging from 5x10{sup 13} to 1x10{sup 15} ions/cm{sup 2} at room temperature. The cell adhesion tests gave interesting results that the number of the neutral granulocytes and the macrophages adhering on surface were reduced significantly after ion implantation. The optimal fluence was about 4x10{sup 14} ions/cm{sup 2}. The hydrophobicity imparted to the lens surface was also enhanced. The results of X-ray photoelectron spectroscopy analysis indicated that ion implantation resulted in the cleavage of some pendant groups, the oxidation of the surface, and the formation of some new chemical bonds, which was probably the main reason for the cell adhesion change.

  19. A truly knotless technique for scleral fixation of intraocular lenses: Two-year results

    Directory of Open Access Journals (Sweden)

    Naresh K Yadav

    2012-01-01

    Full Text Available Scleral fixated intraocular lens (SFIOL is a safe and effective option for managing optical aphakia. Suture related complications like suture erosion, suture breakage, endophthalmitis, etc. are unique to SFIOL. The knots can be covered by partial thickness flaps or they can be rotated into scleral tissues without flaps to reduce the complications. We performed a recently described novel technique which obviates the need for knot and scleral flaps in securing the SFIOL. This novel 2-point Ab externo knotless technique may reduce the knot related problems. Twenty-three eyes undergoing this knotless SFIOL procedure were analyzed for intraoperative and postoperative complications. Twenty-two eyes either maintained or improved on their preoperative vision. All patients had a minimum follow-up of 24 months.

  20. One Year Follow-Up After Veriflex Phakic Intraocular Lenses Implantation for Correction of Myopia

    Science.gov (United States)

    Pjano, Melisa Ahmedbegovic; Biscevic, Alma; Grisevic, Senad; Pidro, Ajla; Ratkovic, Mirko; Bohac, Maja; Husovic, Amila Alikadic; Gojak, Refet

    2016-01-01

    Objectives: The aim of this study was to evaluate visual and refractive outcomes after Veriflex phakic intraocular lenses (pIOL) implantation in moderately myopic eyes as well as postoperative complications. Methods: This prospective clinical study included 40 eyes of 26 patients which underwent implantation of Veriflex for correction of myopia from -6.00 to -14.50 diopters (D) in the Eye Clinic Svjetlost Sarajevo, from January 2011 to January 2014. Uncorrected distance visual acuity (UDVA), manifest residual spherical equivalent (MRSE), intraocular pressure (IOP), endothelial cell (EC) density were evaluated at one, three, six and 12 months. Other complications in postoperative period were evaluated. For statistical analysis SPSS for Windows and Microsoft Excel were used. Results: Out of 26 patients 14 had binocular and 12 monocular procedure, with mean age of 29.8±6.5 years. After 12 months mean UDVA was 0.73±0.20. Mean MRSE was -0.39±0.31D and 90% of eyes had MRSE within ±1D. EC loss was 7.18±4.33%. There was no significant change of IOP by the end of 12 months follow up period. The only intraoperative complication was hyphema and occurred in one eye. Few postoperative complications were: subclinical inflammation in three eyes (7,5%), pigment dispersion in four eyes (10%), ovalisation of papilla in 2 eyes (5%) and decentration of pIOL in 2 eyes (5%). Conclusion: Implantation of iris-claw phakic lenses Veriflex for treating moderately high myopia is a procedure with good visual and refractive results and few postoperative complications. PMID:27482131

  1. Vision in semi-aquatic snakes: Intraocular morphology, accommodation, and eye: Body allometry

    Science.gov (United States)

    Plylar, Helen Bond

    Vision in vertebrates generally relies on the refractive power of the cornea and crystalline lens to facilitate vision. Light from the environment enters the eye and is refracted by the cornea and lens onto the retina for production of an image. When an animal with a system designed for air submerges underwater, the refractive power of the cornea is lost. Semi-aquatic animals (e.g., water snakes, turtles, aquatic mammals) must overcome this loss of corneal refractive power through visual accommodation. Accommodation relies on change of the position or shape of the lens to change the focal length of the optical system. Intraocular muscles and fibers facilitate lenticular displacement and deformation. Snakes, in general, are largely unstudied in terms of visual acuity and intraocular morphology. I used light microscopy and scanning electron microscopy to examine differences in eye anatomy between five sympatric colubrid snake species (Nerodia cyclopion, N. fasciata, N. rhombifer, Pantherophis obsoletus, and Thamnophis proximus) from Southeast Louisiana. I discovered previously undescribed structures associated with the lens in semi-aquatic species. Photorefractive methods were used to assess refractive error. While all species overcame the expected hyperopia imposed by submergence, there was interspecific variation in refractive error. To assess scaling of eye size with body size, I measure of eye size, head size, and body size in Nerodia cyclopion and N. fasciata from the SLU Vertebrate Museum. In both species, body size increases at a significantly faster rate than head size and eye size (negative allometry). Small snakes have large eyes relative to body size, and large snakes have relatively small eyes. There were interspecific differences in scaling of eye size with body size, where N. fasciata had larger eye diameter, but N. cyclopion had longer eyes (axial length).

  2. Latanoprost ophthalmic solution in the treatment of open angle glaucoma or raised intraocular pressure: a review

    Directory of Open Access Journals (Sweden)

    Andrea Russo

    2009-01-01

    Full Text Available Andrea Russo, Ivano Riva, Teodoro Pizzolante, Federico Noto, Luciano QuarantaCattedra di Malattie dell’Apparato Visivo, Università degli studi di Brescia, USVD “Centro per lo studio del Glaucoma” Spedali Civili di BresciaAbstract: Latanoprost is a prostaglandin F2-alpha isopropyl ester prodrug which is rapidly hydrolyzed by esterases in the cornea to the biologically active latanoprost acid. When latanoprost is topically administered into the eye, the cornea seems to act like as a slow-release depot to the anterior segment. One hour after administration maximum concentration is found in the iris, followed by the anterior chamber and the ciliary body. Despite extensive research, controversy remains about the real mechanism of action of this drug. Immunohistochemical data have shown that the intraocular pressure (IOP reduction with topical prostaglandin F2-alpha is associated with a reduction of collagens within the uveoscleral outflow pathway. Evidence from several experimental and clinical studies suggests that latanoprost is a valuable addition first-line treatment alternatives for glaucoma, ocular hypertension and even angle-closure glaucoma. Strong points are its efficacy, which is demonstrated to be higher than that of brimonidine, dorzolamide and timolol with fewer systemic adverse effects; a convenient administration schedule; and the IOP-controlling pattern, which is relatively flat compared with timolol and dorzolamide, and enables better control in glaucoma progression, since large fluctuations may be associated with the risk of developing glaucoma in untreated ocular hypertensive subjects.Keywords: latanoprost, intraocular pressure, glaucoma, ocular hypertension

  3. Wavefront analysis and modulation transfer function of three multifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Santhiago Marcony

    2010-01-01

    Full Text Available Purpose: To evaluate wavefront performance and modulation transfer function (MTF in the human eye after the implantation of diffractive or refractive multifocal intraocular lenses (IOLs. Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA were measured in 60 patients after bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon, 40 eyes received the refractive ReZoom (Advanced Medical Optics and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics. The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA, followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group ( P < 0.001, but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group ( P = 0.007. Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil ( P < 0.001 at all spatial frequencies. Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.

  4. Gauge Transconjunctival Sutureless Vitrectomy in Eyes with Posteriorly Dislocated Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Hüseyin Dündar

    2013-04-01

    Full Text Available Pur po se: To evaluate the efficacy and safety of 23-gauge (23G pars plana vitrectomy (PPV in dislocated intraocular lens (IOL cases: In early- and late-term follow-up. Ma te ri al and Met hod: In this retrospective study, the medical records of 17 patients who underwent 23 G PPV treatment for dislocated IOL between January 2009 and June 2011 were analyzed. Detailed ophthalmologic examination was performed in all patients; intraoperative and postoperative complications were recorded. Re sults: In this study, mean follow-up time was 9.0 (4-22 months and mean age was 60.8 (8-82 years. Mean time after cataract surgery was variable (mean of 28.3 (0-80 months. Four patients had trauma history, five patients had pseudoexfoliation syndrome, and two patients had pathologic myopia. Dislocated IOL was placed into the sulcus in nine patients (52.9%. In two cases (11.7%, the IOLs were removed, and the patients were left aphakic. In two cases out of other 6 (11.7%, the dislocated IOL was changed with scleral fixation lens, whereas in the other four cases (23.5%, IOL was changed with iris claw lens. One patient (5.8% remained at the same level of vision, while twelve (70.5% cases increased two or more lines in BCVA. The vision was decreased in two cases. Intraocular pressure elevation controlled by medication was observed in one case. For two days, hypotony was observed in one patient. Dis cus si on: 23 G PPV technique is an effective and safe method for removing and repositioning of dislocated IOL in the vitreous. (Turk J Ophthalmol 2013; 43: 99-102

  5. Intracapsular dexamethasone implant in patients undergoing phacoemulsification and intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Lucas Monferrari Monteiro Vianna

    2013-08-01

    Full Text Available PURPOSE: To relate the outcomes of 7 eyes of 7 patients in which a dexamethasone 0.7 mg implant (Ozurdex® was placed inside the capsule bag after phacoemulsification and intraocular lens (IOL implantation and compare with the fellow eyes, that were operated by the same technique and received dexamethasone eyedrops in the post-operatory. METHODS: Report review of 7 eyes of 7 patients who received dexamethasone 0.7 mg implant after phacoemulsification and IOL, comparing them to the fellow eyes. All the patients underwent bilateral cataract surgery, with one month interval, by the same technique and by experienced surgeons, without complications. Post operatory medication consisted of moxifloxacin eye drops for all the 14 eyes and topic dexamethasone for the 7 eyes that did not received the implant. RESULTS: Nuclear cataract classification (according to LOCS III was 3.28 ± 0.69 in the implant eye group and 3.14 ± 0.83 in the fellow eye group. Postoperative best spectacle correct visual acuity (BSCVA was 0.85 ± 0.12 and 0.87 ± 0.13, respectively in the implant and fellow eye groups. The intraocular pressure remained stable and similar to the pre-operative measurements. Anterior chamber reaction and cornea edema were similar in both groups in the follow-up. Two of the four no sutured pellet migrated to the anterior chamber during the first post-operative week and had to be repositioned. Another no sutured pellet dislocated and remained partially inside the capsule bag. The 3 patients with IOL haptic-sutured pellet had no complications. CONCLUSIONS: In the present study, dexamethasone 0.7mg implant were effective in controlling the inflammation after phacoemulsification and IOL implantation, with no significant side effects.

  6. OUTCOME OF PHACOEMULSIFICATION WITH INTRAOCULAR LENS IMPLANTATION IN PATIENTS WITH HIGH MYOPIA

    Directory of Open Access Journals (Sweden)

    Sunil

    2015-11-01

    Full Text Available : OBJECTIVE: To evaluate the visual and refractive outcomes of phacoemulsification with intraocular lens (IOL implantation in highly myopic eyes and to assess the intraoperative and postoperative complications. SETTINGS: Tertiary care Centre Ranchi, India. METHODS: Consecutive patients with high myopia were retrospectively studied for outcomes and complications after phacoemulsification and IOL implantation. RESULTS: The study included 125 eyes of 89 patients (53 females and 36 males with a mean age of 56.01±9.51 years and mean follow-up of 19.45±4.07 months. The mean axial length was 29.58±2.57mm and power of the IOL ranged from −4.00 D to + 17.00 D. The mean preoperative logMAR Best corrected visual acuity (BCVA was 0.82±0.26 which improved to 0.38±0.29 at one month and to 0.43±0.33 at last follow-up, the improvement in vision was statistically significant (P<0.0001, paired t test. Postoperatively, 80 eyes (64% had a BCVA between 0.00 logMAR (20/20 and 0.30 logMAR (20/40. Pre-existing myopic chorioretinal degeneration (13.6% was most common factor causing decreased visual acuity. The mean spherical equivalent at one month postoperative was -0.06±1.28 D. The complications included posterior capsule rupture (5.6%, zonular dehiscence (1.6%, retinal detachment (1.6%, cystoid macular edema (8.8% and posterior capsule opacifications (10.4%. CONCLUSIONS: Phacoemulsification with intraocular lens implantation is a safe and effective procedure to improve patients visual acuity in those with high myopia.

  7. In Vivo Imaging of Intraocular Fluidics in Vitrectomized Swine Eyes Using a Digital Fluoroscopy System

    Directory of Open Access Journals (Sweden)

    Tamer Tandogan

    2016-01-01

    Full Text Available Purpose. To describe the characteristics of intraocular fluidics during cataract surgery in swine eyes with prior vitrectomy. Methods. We prepared three groups of enucleated swine eyes (nonvitrectomized, core, and totally vitrectomized. Irrigation and aspiration were performed (2.7 mm conventional sleeved phacosystem using a balanced saline solution mixed with a water-soluble radiopaque contrast medium at 1 : 1 ratio. We imaged the eyes using a digital fluoroscopy system (DFS during phacoemulsification and compared the characteristics of the intraocular fluid dynamics between the groups. Results. The anterior chamber depth (ACD after the commencement of irrigation differed between groups (2.25±0.06 mm; 2.33±0.06 mm; 3.17±0.11 mm, as well as the height of the fluid flowing from the anterior chamber into the posterior cavity that was identified by lifting up the iris to correct the infusion deviation syndrome (0.00±0.00 mm; 0.41±0.04 mm; 2.19±0.35 mm. Conclusions. DFS demonstrated differences in fluid dynamics during phacoemulsification in swine eyes with or without prior vitrectomy. In completely vitrectomized eyes, the large ACD, which developed during phacoemulsification, could be reduced by lifting the iris and allowing the fluid to shift to the posterior cavity. Recognizing the differences in fluidics of vitrectomized eyes as compared to those of the nonvitrectomized eyes may reduce the frequency of intraoperative complications.

  8. Toric intraocular lenses for correction of astigmatism in keratoconus and after corneal surgery

    Directory of Open Access Journals (Sweden)

    Mol IEMA

    2016-06-01

    Full Text Available Ilse EMA Mol,1,2 Bart TH Van Dooren1,2 1Department of Ophthalmology, Amphia Hospital, Breda, 2Department of Ophthalmology, Erasmus Medical Center, Rotterdam, the Netherlands Purpose: To describe the results of cataract extraction with toric intraocular lens (IOL implantation in patients with preexisting astigmatism from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery.Methods: Cataract patients with topographically stable, fairly regular (although sometimes very high corneal astigmatism underwent phacoemulsification with implantation of a toric IOL (Zeiss AT TORBI 709, Alcon Acrysof IQ toric SN6AT, AMO Tecnis ZCT. Postoperative astigmatism and refractive outcomes, as well as visual acuities, vector reduction, and complications were recorded for all eyes.Results: This study evaluated 17 eyes of 16 patients with a mean age of 60 years at the time of surgery. Mean follow-up in this study was 12 months. The corrected distance Snellen visual acuity (with spectacles or contact lenses 12 months postoperatively was 20/32 or better in 82% of eyes. The mean corneal astigmatism was 6.7 diopters (D preoperatively, and 1.5 D of refractive cylinder at 1-year follow-up. No vision-compromising intra- or postoperative complications occurred and decentration or off-axis alignment of toric IOLs were not observed.Conclusion: Phacoemulsification with toric IOL implantation was a safe and effective procedure in the three mentioned corneal conditions. Patient selection, counseling, and IOL placement with optimal astigmatism correction are crucial. Keywords: toric intraocular lens, phacoemulsification, corneal astigmatism, keratoconus, postkeratoplasty, postpterygium surgery

  9. Correction of high myopia with foldable Artiflex Phakic intraocular lenses: 1 year follow-up results.

    Directory of Open Access Journals (Sweden)

    Hassan Hashemi

    2013-09-01

    Full Text Available To assess the one year results of Artiflex Phakic intraocular lens (IOL implantation in the treatment of high myopia. In this non-random interventional study, myopic patients with spherical equivalent worse than -5.0 diopters (D who were not eligible for laser surgery were assessed. All patients had refraction, uncorrected and best corrected visual acuity tests (UCVA and BCVA, endothelial cell count (ECC, and measurement of the anterior chamber depth and intraocular pressure before surgery and at 1, 3, 6, and 12 months after surgery. Main outcome measures of this study were refractive stability, refractive predictability, safety, and efficacy after implanting Artiflex IOLs. We studied 53 eyes of 20 female and 8 male patients. The mean preoperative spherical equivalent was -10.22±3.02 D which reached -0.69±1.08 D one year after surgery (P<0.001. On the last follow-up visit, 75% of the eyes were within +0.5 D of emmetropia, 2 eyes had lost one line of BCVA, 18.75% had gained one line and 31.25% had gained 2 or more lines of BCVA. Others showed no change in BCVA. At one year after surgery, 72.2% of the eyes had 20/25 vision or better. The safety and efficacy indices were 1.16 and 1.05, respectively. ECC showed 3.04% decrease (P=0.176. In cases where laser surgery is not an option for myopic patients, use of Artiflex IOLs can have good results with acceptable safety and efficacy.

  10. Brinzolamide nanocrystal formulations for ophthalmic delivery: reduction of elevated intraocular pressure in vivo.

    Science.gov (United States)

    Tuomela, Annika; Liu, Peng; Puranen, Jooseppi; Rönkkö, Seppo; Laaksonen, Timo; Kalesnykas, Giedrius; Oksala, Olli; Ilkka, Jukka; Laru, Johanna; Järvinen, Kristiina; Hirvonen, Jouni; Peltonen, Leena

    2014-06-01

    Nanocrystal-based drug delivery systems provide important tools for ocular formulation development, especially when considering poorly soluble drugs. The objective of the study was to formulate ophthalmic, intraocular pressure (IOP) reducing, nanocrystal suspensions from a poorly soluble drug, brinzolamide (BRA), using a rapid wet milling technique, and to investigate their IOP reducing effect in vivo. Different stabilizers for the nanocrystals were screened (hydroxypropyl methylcellulose (HPMC), poloxamer F127 and F68, polysorbate 80) and HPMC was found to be the only successful stabilizer. In order to investigate both the effect of an added absorption enhancer (polysorbate 80) and the impact of the free drug in the nanocrystal suspension, formulations in phosphate buffered saline (PBS) at pH 7.4 and pH 4.5 were prepared. Particle size, polydispersity (PI), solid state (DSC), morphology (SEM) as well as dissolution behavior and the uniformity of the formulations were characterized. There was rapid dissolution of BRA (in PBS pH 7.4) from all the nanocrystal formulations; after 1 min 100% of the drug was fully dissolved. The effect was significantly pronounced at pH 4.5, where the dissolved fraction of drug was the highest. The cytotoxicity of nanocrystal formulations to human corneal epithelial cell (HCE-T) viability was tested. The effects of the nanocrystal formulations and the commercial product on the cell viability were comparable. The intraocular pressure (IOP) lowering effect was investigated in vivo using a modern rat ocular hypertensive model and elevated IOP reduction was seen in vivo with all the formulations. Notably, the reduction achieved in experimentally elevated IOP was comparable to that obtained with a marketed product. In conclusion, various BRA nanocrystal formulations, which all showed advantageous dissolution and absorption behavior, were successfully formulated. PMID:24680962

  11. Comparative study on syphilis antibody in blood and aqueous humor of intraocular operational patients%内眼手术患者血液和房水梅毒抗体检测的对比研究

    Institute of Scientific and Technical Information of China (English)

    崔巍; 李红霞; 高伟; 韩晓芳

    2009-01-01

    Objective To probe the positive rates of syphilis in intraocular operational Patients,and to detect the specific and unspecific antibody in Blood and aqueous humor of syphilis Patients for providing basis of aqueous humor route of transmission of syphilis.Method4075 patients being accepted intraocular operation from 2002 were confirmed by preoperative serological tests of these four infectious diseases including Hbs Ag,HCV Antibody,TP Antibody,and HIV Antibody.Infection ratio of syphilis in intraocular operational patients were analysed.The specific and unspecific antibody in blood and aqueous humor of syphilis patients was detected by rapid plasma regain circle card(RPR)and treponema pallidum gem agglutination assay(TPHA).Result In 4075 patients being accepted intraocular operation,58 cases patients had syphilis Antibody in blood.in the 58 cases syphilis patients blood serum,the "positive ratio of TPHA was 100%(58 cases)while that ratio in aqueRecently,positive rates of syphilis infection was relatively stabilizing and the syphilis may not infect through aqueous humor.%目的 探讨内眼手术患者中发生梅毒的阳性率,并通过梅毒患者房水中特异性和非特异性抗体的检测,寻找梅毒是否通过房水传播的理论依据.方法 对2004年以来准备接受内眼手术的4075例患者进行常规的传染四项检查,包括乙肝表面抗原(HBsAg),丙型肝炎抗体(HCV抗体),梅毒抗体(TP抗体),艾滋病抗体(HIV抗体)四项指标,并统计梅毒发生的阳性率;应用特异性抗体试验-梅毒螺旋体血球凝结试验(TPHA)和非特异性抗体试验-快速血浆反应素环状卡片试验(RPR)检测梅毒患者血清及房水中的抗体.结果 4075例内眼手术患者有58例患者血液中存在梅毒抗体,阳性率1.42%.58例梅毒患者血液中TPHA阳性检出率为100%(58例),房水中为32.76%(19例)两者比较差异有统计学意义(P<0.05);而同组患者血液中RPR阳性检出率为51.72%(30

  12. Desempenho visual após implante de uma lente intraocular asférica multifocal difrativa Visual performance after implantation of an aspheric multifocal diffractive intraocular lens

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2010-08-01

    Full Text Available OBJETIVO: Avaliar a acuidade visual a distancia, intermediária e perto após o implante de uma lente intraocular (LIO asférica multifocal difrativa AcrySof® ReSTOR® SN6AD1. MÉTODOS: Estudo prospectivo de 50 pacientes com catarata submetidos à facoemulsificação e implante de LIO AcrySof® ReSTOR®. Foram avaliados acuidade visual sem correção (AVSC, acuidade visual com correção (AVCC para longe, acuidade visual para perto corrigida para longe (AVPC e acuidade visual intermediária corrigida para longe (AVIC. Um questionário de satisfação e fenômenos visuais foi administrado ao final do estudo. RESULTADO: Após três meses de cirurgia, a média das acuidades (logMAR era: AVSC, 0,05 ± 0,07; AVCC, 0,00 ± 0,01; AVPC, 0,00 ± 0,0, e AVIC, 0,15 ± 0,05. A AVCC e AVPC era de 20/25 ou melhor em todos os pacientes, sendo a AVIC J3 ou melhor em 83% dos pacientes. Pacientes relataram excelente desempenho visual nas questões relacionadas a atividades para distância, intermediário, e perto com pouca ou nenhuma dificuldade. Nenhum paciente relatou halos ou 'glare' severos, sendo os mesmos caracterizados entre nenhum a moderado. CONCLUSÃO: A LIO asférica AcrySof® ReSTOR® SN6AD1 mostrou excelentes resultados na visão para longe, perto e intermediário, além de apresentar uma baixa incidência de fenômenos visuais.PURPOSE: To evaluate distance, intermediate, and near vision after aspheric multifocal diffractive AcrySof® ReSTOR® SN6AD1 intraocular lens (IOL implantation. METHODS: Prospective study of 50 patients with cataract that had phacoemulsification and AcrySof® ReSTOR® IOL implantation. Uncorrected distance vision acuity (UDVA, corrected distance visual acuity (CDVA, distance-corrected near visual acuity (DCNVA, and distance-corrected intermediate visual acuity (DCIVA were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered at the end of the study. RESULTS: Three months

  13. Hookworm infection

    Science.gov (United States)

    Hookworm disease; Ground itch; Ancylostoma duodenale infection; Necator americanus infection; Parasitic infection - hookworm ... with any of the following roundworms: Necator americanus Ancylostoma ... Ancylostoma ceylanicum Ancylostoma braziliense The first 2 ...

  14. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Potvin, Rick

    2016-01-01

    Purpose To compare the visual acuity (VA) and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL) and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye. Patients and methods Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated. Results Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (P<0.05) at vergences from −0.5 to −1.5 D (from 2 m to 67 cm viewing distance, P<0.05). There was no statistically significant difference in the near vision subscale scores of the 39-question National Eye Institute Visual Function Questionnaire or the overall scores of the Quality of Vision questionnaire, though significantly more trifocal subjects reported that the observed visual disturbances were “bothersome” (P<0.05). Conclusion Both lens modalities provided subjects with excellent binocular near and distance vision, with similar low rates of visual disturbances and good reported functional vision. The trifocal IOL provided significantly better intermediate VA in the viewing distance range of 2 m to 67 cm, corresponding to viewing things such as a car dashboard or grocery shelf. VA was similar between groups at viewing distances from 60 to 40 cm, corresponding to computer or reading distance. PMID:27274184

  15. The new factors defining variability of circadian’s rhythms of intraocular and perfusion pressure of glaucoma patients

    Directory of Open Access Journals (Sweden)

    N. A. Baranova

    2016-01-01

    Full Text Available Currently, the most scientifically based local risk and progressive factors are elevated levels of intraocular pressure and its instability during the day, caused by local hydromechanical disturbances. However, the other factors affecting the circadian changes of intraocular pressure levels are still evaluated. It was found that light is one of the most important factors affecting the intensity of the cyclical fluctuations of various biological processes, including, and fluctuations of intraocular pressure. At the same time, glaucoma can lead to a variety of sleep disorders, due to a mismatch between cycles «sleep-wake». One if this reason is the death of retinal ganglion cells and their axons. Such damage indirectly lead to a decrease in production of the pigment melanopsin, which is located in the retina. It is not involved in the visual process, but ensures the implementation of circadian rhythms «sleep-wake» and mediated suppression of epiphyseal melatonin. Most likely, melatonin plays a protective role in the occurrence and progression of glaucoma, protecting retinal cells against free radicals and has a direct impact on the intraocular pressure level. Several studies have shown that the circadian change in intraocular pressure levels, and in particular, its substantial reduction, is influenced by melatonin. In this regard, glaucoma is a disease in which the death of retinal cells, including producing melanopsin, a unique opportunity to study violations of cyclic rhythms. Melatonin acts on such established risk factors and progression of glaucoma as hypertension and diabetes. There are published results of the use of melatonin agonists in the experiment and clinical practice. So, in addition to local and systemic hypotensive action, normalizes sleep patients. Data about the melatonin’s effects on the direct and indirect reduction of intraocular pressure, neuroprotective effects and reducing symptoms of depression can

  16. The Path to Open-Angle Glaucoma Gene Discovery: Endophenotypic Status of Intraocular Pressure, Cup-to-Disc Ratio, and Central Corneal Thickness

    OpenAIRE

    Charlesworth, Jac; Kramer, Patricia L.; Dyer, Tom; Diego, Victor; Samples, John R.; Craig, Jamie E; Mackey, David A.; Hewitt, Alex W; Blangero, John; Wirtz, Mary K.

    2010-01-01

    The primary open-angle glaucoma (POAG) risk factors intraocular pressure, vertical cup-to-disc ratio, and central corneal thickness are shown to be highly heritable in 22 large POAG families from Australia and the Northwest Pacific region of the United States. Furthermore, bivariate genetic analysis reveals that both intraocular pressure and vertical cup-to-disc ratio represent potentially useful endophenotypes for the genetic dissection of POAG risk.

  17. Effects of systemic domestic recombinant human erythropoietin on HIF-1α expression in the retina in a rabbit model of acute high intraocular pressure

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective To observe the expression of hypoxia inducible factor-1α (HIF-1α) in the retina of rabbits with acute high intraocular pressure and to investigate the mechanism of systemic domestic recombinant human erythropoietin (rhEPO) protecting the retina from ischemia-reperfusion injury. Methods First,control group and model group were established in rabbit eyes. The acute high intraocular pressure model was established by saline perfusion into anterior chamber,and then hypodermic injection of domestic rhEP...

  18. Estudo do comportamento da pressão intra-ocular em pacientes diabéticos, hipertensos e normais (Projeto Glaucoma) Analysis of the intraocular pressure in diabetics, hypertensive and normal patients (Glaucoma Project)

    OpenAIRE

    Kenji Sakata; Maurício Maia; Leonardo Matsumoto; Emerson K. Oyamaguchi; Ana Cristina A. Carvalho; Northon Knoblauch; Adilson Gil Oliveira Filho

    2000-01-01

    Objetivo: Analisar os valores da pressão intra-ocular (PIO) entre diferentes grupos de pacientes (diabéticos, hipertensos com ou sem retinopatia) e a população normal. Métodos: Realizou-se a aferição da pressão intra-ocular (PIO) em um total de 924 olhos de 482 pacientes com idade igual ou maior que 40 anos (x=56,70; dp=11,89) examinados segundo um protocolo de estudo que incluiu medida da PIO, pressão arterial e glicemia, além da fundoscopia. A determinação da PIO foi obtida pelo tonômetro d...

  19. A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery

    Directory of Open Access Journals (Sweden)

    Bikramjit Das

    2016-02-01

    Full Text Available BACKGROUND: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. METHODS: Ninety adult patients were randomly assigned to study group or control group. Study group (n = 45 - Airtraq laryngoscope was used for laryngoscopy. Control group (n = 45 - conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngoscopy was done as per group protocol. Intraocular pressure and haemodynamic parameters were recorded just before insertion of the device and subsequently three times at an interval of one minute after insertion of the device. RESULTS: Patient characteristics, baseline haemodynamic parameters and baseline intraocular pressure were comparable in the two groups. Following insertion of the endotracheal tube with Macintosh laryngoscope, there was statistically significant rise in heart rate and intraocular pressure compared to Airtraq group. There was no significant change in MAP. Eight patients in Macintosh group had tongue-lip-dental trauma during intubation, while only 2 patients received upper airway trauma in Airtraq group. CONCLUSION: We conclude that Airtraq laryngoscope in comparison to Macintosh laryngoscope results in significantly fewer rises in intraocular pressure and clinically less marked increase in haemodynamic response to laryngoscopy and intubation.

  20. The Influence of Central Corneal Thickness and Corneal Curvature and Axial Length on the Measurement of Intraocular Pressure

    Institute of Scientific and Technical Information of China (English)

    Qing Li; Minru Li; Zhigang Fan; Ningli Wang

    2002-01-01

    Purpose: To examine the influence of central corneal thickness (CCT), corneal curvature (CC), and axial length (AL) on intraocular pressure (IOP).Methods: Eighty-one clinically normal eyes were included in our study. The IOP, CCT, CC, AL were measured using a Goldmann applanation tonometer, optical pachymeter, keratometer and A-scan ultrasound biometer respectively in all subjects.Results: A highly significant positive correlation was identified between IOP and CCT. Linear regression analysis suggests that an increase in CCT of 0. 010 mm is associated with a 4. 946 mmHg increment in IOP. No significant positive correlation was identified between IOP and CC. P values are 0. 724 and 0.414 respectively for vertical and horizontal readings. A paradoxically reversed correlation was present between IOP and axial length.Conclusion: Corneal thickness is a very important confounding factor in the measurement of intraocular pressure, which warrants further attention in our clinical practice.

  1. Small-aperture corneal inlay in presbyopic patients with prior phakic intraocular lens implantation surgery: 3-month results

    Directory of Open Access Journals (Sweden)

    Huseynova T

    2013-08-01

    Full Text Available Tukezban Huseynova,1 Tomomi Kanamori,1 George O Waring IV,2 Minoru Tomita1,3,4 1Shinagawa LASIK Center, Tokyo, Japan; 2Medical University of South Carolina, Charleston, SC, USA; 3Wenzhou Medical College, Wenzhou, People’s Republic of China; 4Eye Can Cataract Surgery Center, Metro Manila, Philippines Abstract: We report a series of three case reports of KAMRA inlay implantation procedures in presbyopic patients with a history of prior phakic intraocular lens implantation surgery. Three-month results showed a two to five-line improvement for uncorrected near visual acuity. The absolute uncorrected near visual acuity change for case 1 was from J4 to J2, for case 2 was from J6 to J4, and for case 3 was from J10 to J5. No significant change of uncorrected distance visual acuity was observed in all three cases. Keywords: phakic intraocular lens, IOL, KAMRA, intracorneal inlay

  2. Investigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions

    OpenAIRE

    Takashina H; Watanabe A; Tsuneoka H

    2015-01-01

    Hirotsugu Takashina,1,2 Akira Watanabe,2 Hiroshi Tsuneoka2 1Department of Ophthalmology, National Hospital Organization Sagamihara Hospital, Sagamihara, Kanagawa, Japan; 2Department of Ophthalmology, Jikei University School of Medicine, Minato-ku, Tokyo, Japan Background: The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions.Methods: ...

  3. 24-hour intraocular pressure in glaucoma patients randomized to receive dorzolamide or brinzolamide in combination with latanoprost

    OpenAIRE

    Oishi, Yoshimi

    2009-01-01

    Yoshimi Nakamura, Shusaku Ishikawa, Yuko Nakamura, Hiroshi Sakai, Ichiko Henzan, Shoichi SawaguchiDepartment of Ophthalmology, University of the Ryukyus Faculty of Medicine, Okinawa, JapanPurpose: To investigate the efficacy of dorzolamide 1% (bid or tid) or brinzolamide 1% bid on 24-hour intraocular pressure (IOP) control as well as patients’ preference for either drug when added in combination with latanoprost against glaucoma (IOP, ≥18 mmHg).Methods: In this randomized cro...

  4. Safety and tolerability of tafluprost in treatment of elevated intraocular pressure in open-angle glaucoma and ocular hypertension

    OpenAIRE

    Dorota Pozarowska

    2010-01-01

    Dorota PozarowskaDepartment of Ophthalmology, Medical University, Lublin, PolandAbstract: Glaucoma is one of the most common neuropathies of the optic nerve. An elevated intraocular pressure (IOP) is a well documented risk factor for the development and progression of this disease. Until now, IOP reduction is the only well documented successful method of glaucoma treatment. Among the many hypotensive drugs, prostaglandin analogs are proved to be the most potent antiglaucoma agents, with very ...

  5. Corneal Endothelial Cell Changes Due to Combined Phacoemulsification-Posterior Chamber Intraocular Lens Implantation and Transpupillary Silicone Oil Removal

    OpenAIRE

    Mehmet Hanifi Alp; Haluk Esgin

    2014-01-01

    Objectives: The aim of this study was to evaluate the effects of combined phacoemulsification-posterior chamber intraocular lens (PCIOL) implantation and removal of transpupillary silicone oil on the corneal endothelial cell layer. Materials and Methods: In this study, we included seven eyes of 7 patients who had intravitreal hemorrhage resulting from retinal detachment or tractional retinal detachment due to proliferative diabetic retinopathy and who underwent pars plana vitrectomy ...

  6. Mirtogenol® potentiates latanoprost in lowering intraocular pressure and improves ocular blood flow in asymptomatic subjects

    OpenAIRE

    Schonlau, Frank

    2010-01-01

    Robert D Steigerwalt Jr1, Gianni Belcaro1, Paolo Morazzoni2, Ezio Bombardelli2, Carolina Burki3, Frank Schönlau4 1Department of Biomedical Sciences, University of Chieti-Pescara, San Valentino, Italy; 2Indena S.p.A. Scientific Department, Milan, Italy; 3Horphag Research (UK) Ltd., Geneva, Switzerland; 4Horphag Research (UK) Ltd. South Kensington, London UKPurpose: The dietary supplement Mirtogenol® was previously shown to lower elevated intraocular pressure (IOP). We here pre...

  7. Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye

    OpenAIRE

    Fujikado T; Saika M

    2014-01-01

    Takashi Fujikado,1 Makoto Saika2 1Department of Applied Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan; 2Research and Development Department of Topcon Corporation, Tokyo, Japan Purpose: To examine the effect of misalignment (decentration and tilt) of intraocular lenses (IOLs) on retinal image quality using a water-immersed model eye with corneal spherical aberration adjusted to the values found in normal human eyes (spherical aberration 0.25 µm; pupil diame...

  8. Comparison of Visual Quality after Implantation of Big Bag and Akreos Adapt Intraocular Lenses in Patients with High Myopia

    Institute of Scientific and Technical Information of China (English)

    Shengsheng Ma; Dongjian Zheng; Ling Lin; Fanjian Meng; Yonggang Yuan

    2015-01-01

    Purpose: To compare vision quality following phacoemulsifi-cation cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens (IOL) in patients diagnosed with high myopia complicated with cataract. Methods:.This was a randomized prospective control study. The patients with high myopia complicated with cataract , with axial length ≥28 mm,.and corneal astigmatism ≤1D were enrolled and randomly divided into the Big Bag and Akreos Adapt IOL groups. All patients underwent phacoemulsification cataract extraction and lens implantation..At 3 months after surgery,.intraocular high-order aberration was measured by a Tracey-iTrace wavefront aberrometer at a pupil diameter of 5 mm in an absolutely dark room and statistically compared be-tween two groups. The images of the anterior segment of eyes were photographed with a Scheimpflug camera using Penta-cam three-dimensional anterior segment analyzer..The tilt and decentration of the IOL were calculated by Image-pro plus 6.0 imaging analysis software and statistically compared between two groups. Results:.In total,.127 patients (127 eyes),..including 52 males and 75 females, were enrolled in this study. The total high-or-der aberration and coma in the Akreos Adapt group (59 eyes) were significantly higher compared with those in the Big Bag (P0.05). The horizontal and vertical decentration were significantly smaller in the Big Bag lens group than in the Akreos Adapt group (both P0.05). Conclusion:.Both Big Bag and Akreos Adapt IOLs possess relatively good intraocular stability implanted in patients with high myopia. Compared with the Akreos Adapt IOL, the Big Bag IOL presents with smaller intraocular high-order aberra-tion. Coma is the major difference between the two groups.

  9. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was...

  10. Nucleoside-Derived Antagonists to A3 Adenosine Receptors Lower Mouse Intraocular Pressure and Act across Species

    OpenAIRE

    Wang, Zhao; Do, Chi Wai; Avila, Marcel Y.; Peterson-Yantorno, Kim; Stone, Richard A.; Gao, Zhan-Guo; Joshi, Bhalchandra; Besada, Pedro; Jeong, Lak Shin; Jacobson, Kenneth A.; Civan, Mortimer M.

    2009-01-01

    The purpose of the study was to determine whether novel, selective antagonists of human A3 adenosine receptors (ARs) derived from the A3-selective agonist Cl-IB-MECA lower intraocular pressure (IOP) and act across species. IOP was measured invasively with a micropipette by the Servo-Null Micropipette System (SNMS) and by non-invasive pneumotonometry during topical drug application. Antagonist efficacy was also assayed by measuring inhibition of adenosine-triggered shrinkage of native bovine n...

  11. 24-hour intraocular pressure in glaucoma patients randomized to receive dorzolamide or brinzolamide in combination with latanoprost

    OpenAIRE

    Nakamura, Yoshimi; Ishikawa, Shusaku; Nakamura, Yuko; Sakai, Hiroshi; Henzan, Ichiko; Sawaguchi, Shoichi

    2009-01-01

    Purpose: To investigate the efficacy of dorzolamide 1% (bid or tid) or brinzolamide 1% bid on 24-hour intraocular pressure (IOP) control as well as patients’ preference for either drug when added in combination with latanoprost against glaucoma (IOP, ≥18 mmHg). Methods: In this randomized crossover study patients were assigned to receive latanoprost plus either dorzolamide or brinzolamide for four weeks. Thereafter, patients underwent 24-hour IOP monitoring while continuing to receive dorzola...

  12. Pneumococcal Infections

    Science.gov (United States)

    Pneumococci are a type of streptococcus bacteria. The bacteria spread through contact with people who are ill or by healthy people who carry the bacteria in the back of their nose. Pneumococcal infections can be mild or severe. The most common types of infections are Ear infections Sinus infections ...

  13. Treatment of cystoid macular edema secondary to chronic non-infectious intermediate uveitis with an intraocular dexamethasone implant

    Directory of Open Access Journals (Sweden)

    Julia Dutra Rossetto

    2015-06-01

    Full Text Available ABSTRACT Purpose: To evaluate the use of a slow-release dexamethasone 0.7-mg intravitreal implant for cystoid macular edema (CME secondary to intermediate uveitis and refractory to systemic steroids. Methods: A retrospective study of the best-corrected visual acuity (BCVA, intraocular inflammation, intraocular pressure (IOP, fundus photography, optical coherence tomography (OCT, inflammation, and adverse reactions of five patients (women, mean age of 35 years with cystoid macular edema treated with a dexamethasone implant. Patients were evaluated in seven visits until the 150th day after the implant. Results: Four patients had bilateral pars planitis and one had bilateral intermediate uveitis associated with juvenile idiopathic arthritis. Six dexamethasone devices were implanted, under topical anesthesia (one each in six eyes, five patients. The mean follow-up time was 5 months. The best-corrected visual acuity improved in all eyes that received an implant, with five having improvements of two or more lines. Optical coherence tomography showed thinning of the macula in all eyes treated, and we saw a correlation between the best-corrected visual acuity and retinal thinning. No serious adverse events occurred and no significant increase in intraocular pressure was observed. Conclusions: Slow-release dexamethasone intravitreal implants can effectively treat CME secondary to intermediate uveitis and refractory to systemic steroids.

  14. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-05-01

    Full Text Available Kjell G Gundersen,1 Rick Potvin21IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USAPurpose: To compare the visual acuity (VA and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye.Patients and methods: Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated.Results: Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (P<0.05 at vergences from -0.5 to -1.5 D (from 2 m to 67 cm viewing distance, P<0.05. There was no statistically significant difference in the near vision subscale scores of the 39-question National Eye Institute Visual Function Questionnaire or the overall scores of the Quality of Vision questionnaire, though significantly more trifocal subjects reported that the observed visual disturbances were “bothersome” (P<0.05.Conclusion: Both lens modalities provided subjects with excellent binocular near and distance vision, with similar low rates of visual disturbances and good reported functional vision. The trifocal IOL provided significantly better intermediate VA in the viewing distance range of 2 m to 67 cm, corresponding to viewing things such as a car dashboard or grocery shelf. VA was similar between groups at

  15. Intraocular pressure dynamics with prostaglandin analogs: a clinical application of water-drinking test

    Directory of Open Access Journals (Sweden)

    Özyol P

    2016-07-01

    Full Text Available Pelin Özyol,1 Erhan Özyol,1 Ercan Baldemir2 1Ophthalmology Department, 2Biostatistics Department, Faculty of Medicine, Mugla Sitki Kocman University, Mugla, Turkey Aim: To evaluate the clinical applicability of the water-drinking test in treatment-naive primary open-angle glaucoma patients. Methods: Twenty newly diagnosed primary open-angle glaucoma patients and 20 healthy controls were enrolled in this prospective study. The water-drinking test was performed at baseline and 6 weeks and 3 months after prostaglandin analog treatment. Peak and fluctuation of intraocular pressure (IOP measurements obtained with the water-drinking test during follow-up were analyzed. Analysis of variance for repeated measures and paired and unpaired t-tests were used for statistical analysis. Results: The mean baseline IOP values in patients with primary open-angle glaucoma were 25.1±4.6 mmHg before prostaglandin analog treatment, 19.8±3.7 mmHg at week 6, and 17.9±2.2 mmHg at month 3 after treatment. The difference in mean baseline IOP of the water-drinking tests was statistically significant (P<0.001. At 6 weeks of prostaglandin analog treatment, two patients had high peak and fluctuation of IOP measurements despite a reduction in baseline IOP. After modifying treatment, patients had lower peak and fluctuation of IOP values at month 3 of the study. Conclusion: Peak and fluctuation of IOP in response to the water-drinking test were lower with prostaglandin analogs compared with before medication. The water-drinking test can represent an additional benefit in the management of glaucoma patients, especially by detecting higher peak and fluctuation of IOP values despite a reduced mean IOP. Therefore, it could be helpful as a supplementary method in monitoring IOP in the clinical practice. Keywords: glaucoma, intraocular pressure, water-drinking test, prostaglandin analog, intra­ocular pressure fluctuation

  16. Associated depression in pseudophakic patients with intraocular lens with and without chromophore

    Directory of Open Access Journals (Sweden)

    Mendoza-Mendieta ME

    2016-03-01

    Full Text Available María Elena Mendoza-Mendieta, Ana Aurora Lorenzo-Mejía Association to Prevent Blindness in Mexico (APEC, Hospital “Dr Luis Sánchez Bulnes”, Mexico City, Mexico Background: With aging, the crystalline lens turns yellowish, which increases the absorption of wavelengths in the blue electromagnetic spectrum, reducing their photoreception in the retina. Since these wavelengths are the main stimulus in the regulation of the circadian rhythm, progressive reduction in their transmission is associated with chronic sleep disturbances and depression in elderly patients. Cataract extraction improves circadian photoreception at any age. However, lenses that block blue waves have 27% to 38% less melatonin suppression than lenses that block only ultraviolet (UV rays. Purpose: To assess the depression symptoms in subjects who have had bilateral phacoemulsification and intraocular lens (IOL implants, one group with yellow chromophore IOLs and the other group with transparent IOLs were compared. Setting: Association to Prevent Blindness in Mexico (APEC, Hospital “Dr Luis Sánchez Bulnes”. Design: This was an observational, cross-sectional, and single-center study. Materials and methods: Twenty-six subjects between 60 and 80 years of age, with a history of bilateral phacoemulsification and placement of the same type of IOL in both eyes from 4 to 12 months prior to the study, who attended the follow-up visits and agreed to participate in this study, and provided signed informed consent were included in the study. They were asked to answer the short version of the 15-item Geriatric Depression Scale. Results: The average age of the study participants was 72.5±5.94 years. The group without chromophore included 46.1% (n=12 of the patients and the group with chromophore included 53.9% (n=14 of the patients (P=0.088. Conclusion: In the group of patients with IOLs that block the passage of blue light, the depression rate was 21.4%, a rate similar to that

  17. Central corneal thickness and intraocular pressure in the Cameroonian nonglaucomatous population

    Directory of Open Access Journals (Sweden)

    André Omgbwa Eballe

    2010-07-01

    Full Text Available André Omgbwa Eballe1, Godefroy Koki2, Augustin Ellong2, Didier Owono2, Emilienne Epée2, Lucienne Assumpta Bella2, Côme Ebana Mvogo1, Jeanne Mayouego Kouam21Faculty of Medicine and Pharmaceuticals Sciences, University of Douala; 2Faculty of Medicine and Biomedical Sciences, University of Yaoundé, CameroonAim: We performed a prospective, analytical study from 01 January to 31 March 2009 in the Ophthalmology Unit of the Gyneco-Obstetric and Pediatric Hospital of Yaounde, aiming to determine the profile of central corneal thickness (CCT in the Cameroonian nonglaucomatous black population and its relationship with intraocular pressure (IOP.Results and discussion: Four hundred and eighty-five patients (970 eyes meeting our ­inclusion criteria were selected for this study. The average CCT was 529.29 ± 35.9 µm in the right eye (95% confidence interval [CI]: 526.09–532.49, 528.19 ± 35.9 µm in the left eye (95% CI: 524.99–531.40 and 528.74 ± 35.89 µm in both eyes (95% CI: 526.48–531.00, range 440 to 670 µm. The average IOP was 13.01 ± 2.97 mmHg in both eyes (95% CI: 12.82–13.19. A rise in CCT by 100 µm was followed by an increase in IOP of about 2.8 mmHg (95% CI: 2.3–3.6 for both eyes taken together. Linear regression analysis showed that corneal thickness was negatively correlated with age and IOP was positively related with age.Conclusion: CCT in the Cameroonian nonglaucomatous black population was found to be lower compared with CCT values in Caucasian and Asian populations. On the basis of reference values ranging between 527 and 560 µm, an adjustment of IOP values by a correction factor is required for many Cameroonian patients. This will improve the diagnosis and follow-up of glaucoma by helping to detect true ocular hypertension.Keywords: central corneal thickness, intraocular pressure, Cameroon

  18. Desempenho visual dos pacientes pseudofácicos com diferentes lentes intraoculares

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2013-10-01

    Full Text Available OBJETIVO: Comparar a performance visual dos pacientes submetidos ao implante das lentes intraoculares multifocais difrativas Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60WF e Acrysof® SN60AT. MÉTODOS: Estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata, provenientes do ambulatório de oftalmologia do HC-FMUSP. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste, pupilometria e análise de frente de onda por meio do aberrômetro. Todos os exames foram realizados com seis meses de pós-operatório. RESULTADOS: A média de idade dos pacientes foi de 60,7±6,6 anos no grupo Tecnis, 63,1±4,4 anos no grupo Restor e 63,7±4,2 anos no grupo monofocal (SN60AT no olho contralateral SN60WF. A acuidade visual para perto não corrigida e corrigida para longe foi estatisticamente superior nos grupos multifocal Restor e multifocal Tecnis em comparação ao grupo monofocal SN60AT/SN60WF (p<0,001. Não houve diferença estatística entre os grupos na comparação da acuidade visual para longe (p=0,56. A sensibilidade ao contraste fotópica monocular foi estatisticamente inferior nos grupos Restor e Tecnis (p<0,001. A SN60AT apresentou maior aberração esférica comparada a todas as outras lentes (p<0,001. A Tecnis se mostrou com menores valores médios de aberrações esféricas na comparação com a Restor (p<0.001. CONCLUSÃO: A Restor e Tecnis apresentaram melhor acuidade visual para perto do que o grupo monofocal SN60AT/SN60WF. Todas as lentes intraoculares promoveram boa visão para longe. O grupo da Tecnis apresentou melhor sensibilidade de contraste, menos aberrações ópticas e melhor visão intermediária que o grupo Restor.

  19. Long-term visual outcomes after Crystalens® HD intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Karavitaki AE

    2014-05-01

    Full Text Available Alexandra E Karavitaki, Ioannis G Pallikaris, Sophia I Panagopoulou, George A Kounis, George Kontadakis, George D KymionisInstitute of Vision and Optics, University of Crete, Crete, GreecePurpose: Our purpose was to evaluate the long-term visual outcomes after bilateral implantation of Crystalens® HD (Bausch and Lomb, Inc. accommodative intraocular lenses.Methods: In this study, 25 patients (50 eyes who underwent cataract surgery and bilateral Crystalens HD accommodative intraocular lens implantation were included. The Crystalens HD lens was implanted in the bag in both eyes, without any intra- or postoperative complications. The visual parameters measured before and after surgery were: uncorrected distance visual acuity, corrected distance visual acuity (CDVA (using the Early Diabetic Retinopathy Study [EDTRS] logMAR charts, uncorrected intermediate visual acuity, and uncorrected near visual acuity using a Birkhäuser reading chart, at a distance of 66 cm and 33 cm for intermediate and near vision, respectively, directly illuminated by a lamp of 60 watts. After surgery, the patients were evaluated at 1, 3, 6, 12, 24, and 36 months.Results: The mean age was 68.70±7.1 (range: 54 to 83 years. The mean follow-up was 42.72±0.49 (range: 42.33 to 43.27 months. The uncorrected distance visual acuity improved from 0.56±0.41 (range: 0 to 2 preoperatively to 0.19±0.13 (range: 0 to 0.38 (logMAR scale at the last follow-up visit, and the CDVA improved from 0.17±0.18 (range: 0 to 0.7 preoperatively to 0.05±0.05 (range: −0.02 to 0.22 at the last follow-up visit. No eyes lost lines of CDVA during the follow-up period, while 54% of patients gained one or more lines of CDVA. The uncorrected intermediate and near visual acuity was J2 or better in 71% and 69% of our patients, respectively.Conclusion: Crystalens HD implantation seems to provide an improvement in visual acuity for far, intermediate, and near distances.Keywords: presbyopia, accommodation

  20. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = -0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased

  1. Avaliação da sensibilidade ao contraste e da estereopsia em pacientes com lente intra-ocular multifocal Contrast sensitivity and stereopsis in pseudophakic patients with multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Filipe de Oliveira

    2005-08-01

    Full Text Available OBJETIVO: Avaliar a sensibilidade ao contraste e a acuidade estereoscópica em pacientes pseudofácicos, que receberam implante bilateral de lente intra-ocular multifocal. MÉTODOS: Prospectivamente foram realizados testes de sensibilidade ao contraste com o uso da tabela Pelli-Robson e teste de acuidade estereoscópica com emprego do Titmus Stereo Test, em 20 pacientes com implante bilateral de lente intra-ocular multifocal Acrysof Restor®, no pós-operatório de 1 a 2 meses e sem uso de qualquer correção óptica. RESULTADOS:O teste de sensibilidade ao contraste binocular demonstrou que 6 pacientes (30% apresentaram 1,80 unid. log, 13 (65% 1,65 e 1 (5% 1,50. No teste monocular, ocorreram as seguintes respostas: 17 pacientes (85% 1,65 unid. log e 3 (15% 1,50 para o teste do olho direito. O teste do olho esquerdo mostrou que 16 pacientes (80% apresentaram 1,65 unid. log e 4 (20% 1,50. A média e o desvio-padrão da sensibilidade ao contraste testada binocularmente foi 1,69 (±0,08, ao passo que monocularmente foi 1,63 (±0,05 para OD e 1,62 (±0,06 para OE. O teste de acuidade estereoscópica revelou que 12 pacientes (60% obtiveram 40", 6 (30% 50" e 2 (10% 60", com média de 45" e desvio-padrão de ±6,88". CONCLUSÃO: A lente intra-ocular empregada no estudo, proporcionou resultados de sensibilidade ao contraste e acuidade estereoscópica compatíveis e de acordo com critérios de normalidade estabelecidos anteriormente por outros estudos em grupos de pacientes fácicos e pseudofácicos, e portanto, impacto positivo na funcionalidade visual.PURPOSE: To evaluate the contrast sensitivity and stereopsis tests in patients who underwent bilateral implantation of multifocal intraocular lens. METHODS: Tests of contrast sensitivity using the Pelli-Robson chart and stereopsis evaluation with the Titmus Stereo Test were performed in 20 patients 30-60 days after the bilateral implantation of Acrysof Restor® multifocal intraocular lens. RESULTS: The

  2. A capacitor-based sensor and a contact lens sensing system for intraocular pressure monitoring

    Science.gov (United States)

    Chiou, Jin-Chern; Huang, Yu-Chieh; Yeh, Guan-Ting

    2016-01-01

    This study proposes a capacitor-based sensor on a soft contact lens for the measurement of intraocular pressure (IOP). The sensor was designed and fabricated via microelectromechanical system fabrication technologies. The soft contact lens is designed to be worn on a cornea such that the curvature of the contact lens corresponds substantially to that of the cornea. In addition, the contact lens was fabricated via a cast-molding method using poly-2-hydroxyethyl methacrylate to achieve a lens with high oxygen permeability, which can be worn comfortably for a long time. An IOP sensor prototype was implemented, which exhibited 1.2239 pF mmHg-1 (13,171 ppm mmHg-1) sensitivity during measurements of an artificial anterior chamber at pressures between 18 and 30 mmHg. The results indicate that the developed capacitor-based IOP sensor exhibited high stability and reproducibility in a series of measurements performed under various pressures. The capacitance of the proposed IOP sensor can successfully be converted into a digital value via a capacitor-to-digital converter and be transmitted via a commercial wireless telemetry system in this study.

  3. INTRAOCULAR PRESSURE IN SOUTHERN ROCKHOPPER (EUDYPTES CHRYSOCOME) AND MACARONI PENGUINS (EUDYPTES CHRYSOLOPHUS): EVALUATION OF INFLUENCING FACTORS.

    Science.gov (United States)

    Woodhouse, Sarah J; Peterson, Edward L; Schmitt, Todd; Aquino, Susette

    2016-03-01

    Ophthalmic examinations were performed on 160 macaroni penguins (Eudyptes chrysolophus) and 90 southern rockhopper penguins (Eudyptes chrysocome) at eight North American zoos and aquaria. Intraocular pressure (IOP) was measured using rebound tonometry while penguins were held in two different body positions. Correlations between IOP and factors including age, body position, eye pathology, and housing parameters were evaluated. Normal macaroni penguins had a mean IOP of 42.0 ± 9.7 mm Hg. Normal rockhopper penguins had a mean IOP of 32.9 ± 6.2 mm Hg. Neither species had significantly different IOP between sexes or between left and right eyes of the same penguin. In both species, there was a negative linear correlation between age and IOP. In the macaroni population, IOP was significantly higher when IOP measurement was performed before ophthalmic exam; this was not true in rockhoppers. In both species, IOP measured in a horizontal body position was significantly higher than IOP measured in a vertical body position. In both species, eyes with corneal lesions had significantly lower IOP than normal eyes. In the macaroni penguin, eyes with rubeosis iridis had significantly lower IOP than normal eyes. In macaroni penguins, eyes with cataracts had significantly lower mean IOP than normal eyes; this was not true for rockhoppers.

  4. Evaluation of pars plana sclera fixation of posterior chamber intraocular lens

    Directory of Open Access Journals (Sweden)

    Fangju Han

    2014-01-01

    Full Text Available Purpose: The purpose of this study was to evaluate the clinical efficacy and safety of modified posterior chamber intraocular lens (PCIOL implantation with transscleral fixation. Design and Setting: This is a study, which is conducted at Department of Ophthalmology, Jinan Eye Hospital, Jinan Second People′s Hospital. Materials and Methods: A total of 82 patients who were scheduled for sutured PCIOL were divided randomly into modified and conventional groups. The former underwent PCIOL through pars plana fixation with knot buried and without scleral flap and the latter underwent transscleral fixation of PCIOL in the ciliary sulcus. The main outcome measures included operative time, postoperative visual acuity, and postoperative complications. Results: The mean operative time of the modified group was 39.95 ± 5.87 min, which was significantly less than that of the conventional group (45.77 ± 5.21 min; P < 0.05. No difference was found in postoperative visual acuity between the two groups. There were no significant postoperative complications, including knot exposure, endophthalmitis, and retinal detachment in either group. The optical clamping of PCIOL was prone to occur in the conventional group. Conclusion: Modified sutured PCIOL implantation is a safe, effective, and feasible technique for the correction of aphakia in eyes without adequate posterior capsular support.

  5. A knotless, one-haptic fixation of posterior chamber intraocular lenses: one-year results

    Institute of Scientific and Technical Information of China (English)

    Pipat; Kongsap

    2015-01-01

    AIM: To assess the results of a modified technique for scleral fixation of a posterior chamber intraocular lens(IOL) in eyes which had deficient of posterior capsular support.METHODS: This retrospective study was comprised of ten patients with deficient posterior capsular support who underwent one-haptic fixation of posterior chamber IOLs, between February 2010 and October 2011. IOL as implanted with one haptic supported on the capsular remnant and the other haptic drawn into the sulcus by anchoring suture without a knot. All patients were evaluated for pre- and postoperative visual acuity, lens centration, intra-and postoperative complications.RESULTS: A knotless, one-haptic fixation of posterior chamber IOLs has successfully been performed on ten eyes. All cases had inadequate capsular support(i.e. a capsular tear ranged from 5 to 7 clock hours). The average age was 74.25 ±8.87y(SD). The average postoperative uncorrected visual acuity was 0.51 log MAR.Complications included hyphema in one eye, a mild inflammatory reaction in the anterior chamber in two eyes, and a transient rise in IOP in one eye. Neither IOL tilt nor dislocation was observed and there were no later complications.CONCLUSION: In the presence of insufficient capsular support, a knotless, one-haptic fixation of posterior chamber IOLs is a safe and viable option which reduces the operation time, and minimizes postoperative suture-related complications.

  6. A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.

    Science.gov (United States)

    Can, Ertuğrul; Gül, Adem; Birinci, Hakkı

    2016-08-01

    To describe a novel technique for implantation of intraocular lens in the absence of capsular support using a ciliary sulcus guide. Based on the anatomic knowledge of the ciliary sulcus and the sclera, a new instrument was developed to pierce the needle safely through the ciliary sulcus and sclera. While the foldable lens is stored inside the cartridge, the leading haptic is sutured with a cow-hitch knot. The needle is then inserted into the ciliary sulcus guide. The tip of the guide is inserted from the corneal incision and proceeded under the iris to touch and fit the ciliary sulcus. The needle is pushed from back side. The needle comes out at precise point at the sclera. Implantation of the lens was performed through a 2.8 mm clear cornea incision using the injector. The trailing haptic is tied after implantation, and then the same procedure is performed at the opposite side. We performed this technique to 15 aphakic eyes without sufficient capsular support. There was no bleeding or other intraoperative complication. All the points coming out the sclera were between 2 and 2.5 mm from the limbus. The ab interno technique for scleral fixation of IOL is quicker, easier and less traumatic then ab externo techniques. A new ciliary sulcus guide which is usable with both straight and curved needles eliminates the blind maneuvers of ab interno technique and makes this technique more safe and precise.

  7. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach.

    Science.gov (United States)

    Nadal, Jeroni; Kudsieh, Bachar; Casaroli-Marano, Ricardo P

    2015-01-01

    Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL) stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a previously looped nonabsorbable polyester suture. Main Outcome Measures. Best corrected visual acuity (BCVA) LogMAR, corneal astigmatism, endothelial cell count, IOL stability, and postoperative complications. Results. Mean follow-up time was 18.8 ± 10.9 months. Mean surgery time was 33 ± 2 minutes. Mean BCVA improved from 0.30 ± 0.48 before surgery to 0.18 ± 0.60 (p = 0.015) at 1 month, which persisted to 12 months (0.18 ± 0.60). Neither corneal astigmatism nor endothelial cell count showed alterations 1 year after surgery. Complications included IOL subluxation in 1 eye (4%), vitreous hemorrhage in 2 eyes (8%), transient hypotony in 2 eyes (8%), and cystic macular edema in 1 eye (4%). No patients presented retinal detachment. Conclusion. This surgical technique proved successful in the management of dislocated IOL. Functional results were good and the complications were easily resolved. PMID:26294964

  8. Treatment of dystrophic calcification on a silicone intraocular lens with pars plana vitrectomy

    Directory of Open Access Journals (Sweden)

    Mehta N

    2014-07-01

    Full Text Available Nitish Mehta,1 Roger A Goldberg,2 Chirag P Shah21University of Massachusetts Medical School, Worcester, MA, USA; 2Department of Retina, Ophthalmic Consultants of Boston, Boston, Massachusetts, USAPurpose: Dense, vision-obscuring calcification on the posterior aspect of silicone intraocular lenses (IOLs is often not amenable to neodymium:yttrium-aluminum-garnet capsulotomy, and, in prior reports, has required IOL exchange. We report the successful removal of dense calcium deposition on the posterior surface of a three-piece silicone lens using pars plana vitrectomy (PPV.Materials and methods: A 23-gauge PPV was performed using the Stellaris® vitrectomy system. A light pipe was used to retroilluminate the IOL, and a dense fibrous tissue setting with a low cut-rate and high aspiration rate was able to clear the visual axis of the dystrophic calcification without damaging the IOL optic.Results: Visual acuity improved from 20/100 to 20/25.Conclusion: Small-gauge PPV may be utilized to remove dense dystrophic calcium deposits on the lens surface in lieu of IOL exchange. Keywords: cataract surgery, technique, Nd:YAG capsulotomy, IOL exchange

  9. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  10. Distribution of salicylate in lens and intraocular fluids and its effect on cataract formation.

    Science.gov (United States)

    Cotlier, E; Sharma, Y R; Niven, T; Brescia, M

    1983-06-14

    Retrospective studies on cataract development in patients with rheumatoid arthritis or osteoarthritis revealed a retardant effect of aspirin on diabetic and non-diabetic cataracts. The effect of aspirin is dose-dependent. The correlation coefficient between years delay for various cataracts subcategories versus aspirin taken (in tablets per day X years of intake) was 0.69. The ocular pharmacokinetics of 14C acetylsalicylic acid or salicylate were determined after intravenous or intraperitoneal administration to rabbits. 14C acetylsalicylic acid penetrates rapidly into rabbit lens and aqueous humor after intravenous administration. After intraperitoneal administration, salicylate levels in rabbit plasma, similar to those of humans receiving four to six aspirin tablets (325 mg each), result in accumulation of salicylate by lens (mean +/- SD) of 405 +/- 72 mumoles/g and 620 +/- 30 mumoles/g at two and four hours, respectively. At those dosages, salicylate is cleared in 24 hours from rabbit plasma and intraocular fluids, but retained by lens. Penetration of salicylate into rabbit lens and rat lens is dose-dependent. The retardant aspirin effect in diabetic cataracts is linked to inhibition of tissue aldose reductase and lens protein glycosylation. Deceleration of galactose cataract formation in rats occurs after daily salicylate intraperitoneal injections of 100 mg/kg a day. PMID:6859071

  11. Common genetic determinants of intraocular pressure and primary open-angle glaucoma.

    Science.gov (United States)

    van Koolwijk, Leonieke M E; Ramdas, Wishal D; Ikram, M Kamran; Jansonius, Nomdo M; Pasutto, Francesca; Hysi, Pirro G; Macgregor, Stuart; Janssen, Sarah F; Hewitt, Alex W; Viswanathan, Ananth C; ten Brink, Jacoline B; Hosseini, S Mohsen; Amin, Najaf; Despriet, Dominiek D G; Willemse-Assink, Jacqueline J M; Kramer, Rogier; Rivadeneira, Fernando; Struchalin, Maksim; Aulchenko, Yurii S; Weisschuh, Nicole; Zenkel, Matthias; Mardin, Christian Y; Gramer, Eugen; Welge-Lüssen, Ulrich; Montgomery, Grant W; Carbonaro, Francis; Young, Terri L; Bellenguez, Céline; McGuffin, Peter; Foster, Paul J; Topouzis, Fotis; Mitchell, Paul; Wang, Jie Jin; Wong, Tien Y; Czudowska, Monika A; Hofman, Albert; Uitterlinden, Andre G; Wolfs, Roger C W; de Jong, Paulus T V M; Oostra, Ben A; Paterson, Andrew D; Mackey, David A; Bergen, Arthur A B; Reis, André; Hammond, Christopher J; Vingerling, Johannes R; Lemij, Hans G; Klaver, Caroline C W; van Duijn, Cornelia M

    2012-01-01

    Intraocular pressure (IOP) is a highly heritable risk factor for primary open-angle glaucoma and is the only target for current glaucoma therapy. The genetic factors which determine IOP are largely unknown. We performed a genome-wide association study for IOP in 11,972 participants from 4 independent population-based studies in The Netherlands. We replicated our findings in 7,482 participants from 4 additional cohorts from the UK, Australia, Canada, and the Wellcome Trust Case-Control Consortium 2/Blue Mountains Eye Study. IOP was significantly associated with rs11656696, located in GAS7 at 17p13.1 (p=1.4×10(-8)), and with rs7555523, located in TMCO1 at 1q24.1 (p=1.6×10(-8)). In a meta-analysis of 4 case-control studies (total N = 1,432 glaucoma cases), both variants also showed evidence for association with glaucoma (p=2.4×10(-2) for rs11656696 and p=9.1×10(-4) for rs7555523). GAS7 and TMCO1 are highly expressed in the ciliary body and trabecular meshwork as well as in the lamina cribrosa, optic nerve, and retina. Both genes functionally interact with known glaucoma disease genes. These data suggest that we have identified two clinically relevant genes involved in IOP regulation.

  12. Common genetic determinants of intraocular pressure and primary open-angle glaucoma.

    Directory of Open Access Journals (Sweden)

    Leonieke M E van Koolwijk

    Full Text Available Intraocular pressure (IOP is a highly heritable risk factor for primary open-angle glaucoma and is the only target for current glaucoma therapy. The genetic factors which determine IOP are largely unknown. We performed a genome-wide association study for IOP in 11,972 participants from 4 independent population-based studies in The Netherlands. We replicated our findings in 7,482 participants from 4 additional cohorts from the UK, Australia, Canada, and the Wellcome Trust Case-Control Consortium 2/Blue Mountains Eye Study. IOP was significantly associated with rs11656696, located in GAS7 at 17p13.1 (p=1.4×10(-8, and with rs7555523, located in TMCO1 at 1q24.1 (p=1.6×10(-8. In a meta-analysis of 4 case-control studies (total N = 1,432 glaucoma cases, both variants also showed evidence for association with glaucoma (p=2.4×10(-2 for rs11656696 and p=9.1×10(-4 for rs7555523. GAS7 and TMCO1 are highly expressed in the ciliary body and trabecular meshwork as well as in the lamina cribrosa, optic nerve, and retina. Both genes functionally interact with known glaucoma disease genes. These data suggest that we have identified two clinically relevant genes involved in IOP regulation.

  13. Effect of alpha-2-agonist premedication on intraocular pressure after selective laser trabeculoplasty

    Directory of Open Access Journals (Sweden)

    Julius T Oatts

    2015-01-01

    Full Text Available Aim: To determine the effect of alpha-2-agonist (AA premedication (PM on intraocular pressure (IOP following selective laser trabeculoplasty (SLT. Methods: Retrospective cohort study of all patients undergoing 360° SLT at an institution with two prevalent practice patterns consisting of SLT performed with PM and without premedication (NPM with AA. The association between pre- and post-operative IOP was evaluated using a linear regression model in 49 (59% PM and 34 (41% NPM eyes. Results: The prevalence of IOP elevations up to 5 mmHg 1 h postoperatively was similar in both groups, occurring in 18% of PM and in 15% of NPM. Elevations above 5 mmHg were seen in 4% of PM and 8% of NPM (P = 0.732. After correcting for age, gender, diagnosis, number of medications, and preoperative IOP, the presence or absence of AA PM had no significant association with any postoperative IOP (P > 0.5. Conclusion: The practice of using AAs before SLT and measuring IOP at 1 h has not been validated yet adds to expenses and workflow burden. Our retrospective study showed no significant correlation between PM and postoperative or longer-term IOP. IOP at 1 h should be measured in patients who cannot tolerate transient pressure elevations. Further studies are needed to elucidate this relationship.

  14. TRPV4 regulates calcium homeostasis, cytoskeletal remodeling, conventional outflow and intraocular pressure in the mammalian eye

    Science.gov (United States)

    Ryskamp, Daniel A.; Frye, Amber M.; Phuong, Tam T. T.; Yarishkin, Oleg; Jo, Andrew O.; Xu, Yong; Lakk, Monika; Iuso, Anthony; Redmon, Sarah N.; Ambati, Balamurali; Hageman, Gregory; Prestwich, Glenn D.; Torrejon, Karen Y.; Križaj, David

    2016-01-01

    An intractable challenge in glaucoma treatment has been to identify druggable targets within the conventional aqueous humor outflow pathway, which is thought to be regulated/dysregulated by elusive mechanosensitive protein(s). Here, biochemical and functional analyses localized the putative mechanosensitive cation channel TRPV4 to the plasma membrane of primary and immortalized human TM (hTM) cells, and to human and mouse TM tissue. Selective TRPV4 agonists and substrate stretch evoked TRPV4-dependent cation/Ca2+ influx, thickening of F-actin stress fibers and reinforcement of focal adhesion contacts. TRPV4 inhibition enhanced the outflow facility and lowered perfusate pressure in biomimetic TM scaffolds populated with primary hTM cells. Systemic delivery, intraocular injection or topical application of putative TRPV4 antagonist prodrug analogs lowered IOP in glaucomatous mouse eyes and protected retinal neurons from IOP-induced death. Together, these findings indicate that TRPV4 channels function as a critical component of mechanosensitive, Ca2+-signaling machinery within the TM, and that TRPV4-dependent cytoskeletal remodeling regulates TM stiffness and outflow. Thus, TRPV4 is a potential IOP sensor within the conventional outflow pathway and a novel target for treating ocular hypertension. PMID:27510430

  15. Metabolic syndrome: a risk factor for high intraocular pressure in the Israeli population

    Institute of Scientific and Technical Information of China (English)

    Tamara; Wygnanski-Jaffe; Itzhak; Bieran; Dorit; Tekes-Manova; Yair; Morad; Isaac; Ashkenazi; Eedy; Mezer

    2015-01-01

    AIM: To evaluate the association among elevated intraocular pressure(IOP), the metabolic syndrome(Met S), body mass index(BMI), and some of their components in the Israeli population.METHODS: We retrospectively reviewed the charts of12 747 soldiers of the Israeli Defense Forces, aged 35 y or older, who underwent a routine periodical medical examination between 1991 and 2004. None of the subjects received medical treatment for either glaucoma or ocular hypertension. High IOP(>21 mm Hg) was correlated with age, sex, arterial blood pressure, total blood cholesterol levels, triglyceride levels, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, smoking, BMI and Met S.RESULTS: A statistically significant difference was found between the IOP of subjects with a low risk and higher risk for the development of Met S(P <0.0001 for males, P =0.0026 for females). A statistically significant positive correlation was found in male subjects between high BMI and elevated IOP(r =0.11677, P <0.0001).CONCLUSION: Met S and BMI were significantly more prevalent in subjects with increased IOP levels. We suggest that both should be taken into consideration in the assessment of glaucoma suspects.

  16. Ultrasound Biomicroscopy Comparison of Ab Interno and Ab Externo Intraocular Lens Scleral Fixation.

    Science.gov (United States)

    Horiguchi, Lie; Garcia, Patricia Novita; Malavazzi, Gustavo Ricci; Allemann, Norma; Gomes, Rachel L R

    2016-01-01

    Purpose. To compare ab interno and ab externo scleral fixation of posterior chamber intraocular lenses (PCIOL) using ultrasound biomicroscopy (UBM). Methods. Randomized patients underwent ab externo or ab interno scleral fixation of a PCIOL. Ultrasound biomicroscopy was performed 3 to 6 months postoperatively, to determine PCIOL centration, IOL distance to the iris at 12, 3, 6, and 9 hours, and haptics placement in relation to the ciliary sulcus. Results. Fifteen patients were enrolled in the study. The ab externo technique was used in 7 eyes (46.6%) and the ab interno in 8 eyes (53.3%). In the ab externo technique, 14 haptics were located: 4 (28.57%) in the ciliary sulcus; 2 (14.28%) anterior to the sulcus; and 8 (57.14%) posterior to the sulcus, 6 in the ciliary body and 2 posterior to the ciliary body. In the ab interno group, 4 haptics (25.0%) were in the ciliary sulcus, 2 (12.50%) anterior to the sulcus, and 10 (75.0%) posterior to the sulcus, 4 in the ciliary body and 6 posterior to the ciliary body. Conclusions. Ab externo and ab interno scleral fixation techniques presented similar results in haptic placement. Ab externo technique presented higher vertical tilt when compared to the ab interno.

  17. Comparison of shape recovery ratios of single-piece poly(methyl methacrylate) intraocular lens haptics.

    Science.gov (United States)

    Kimura, W; Kimura, T; Sawada, T; Kikuchi, T; Nagai, H; Yamada, Y

    1993-09-01

    We studied shape recovery ratios of several single- and three-piece intraocular lens (IOL) haptics after conducting compression tests for various lengths of time. Results of the comparison of poly(methyl methacrylate) (PMMA) IOL haptics configured of a single piece and of three pieces showed a superior shape recovery ratio for single-piece haptics. Comparisons of the shape recovery ratios among single-piece PMMA haptics and conventional three-piece haptics made of polyvinylidene fluoride (PVDF), PMMA, and polypropylene (PP) revealed that the shape recovery ratio of single-piece PMMA haptics was higher than the ratios of the conventional three-piece PMMA and PP haptics. The ratios of two of three of the single-piece PMMA haptics, however, were lower than the ratios of three-piece PVDF haptics. The form and manufacturing procedures of haptics likely have a significant impact on the shape recovery ratio of haptics, even those made of the same material. Since decentration after IOL surgery could be caused by the condition of the patient's lenticular capsule and Zinn's zonule, it is difficult to conclude that the shape recovery ratio is the only factor in IOL stability. Nevertheless, this study indicates that IOL haptics that cause less decentration and have better mechanical properties should be developed.

  18. Ultrasound Biomicroscopy Comparison of Ab Interno and Ab Externo Intraocular Lens Scleral Fixation

    Directory of Open Access Journals (Sweden)

    Lie Horiguchi

    2016-01-01

    Full Text Available Purpose. To compare ab interno and ab externo scleral fixation of posterior chamber intraocular lenses (PCIOL using ultrasound biomicroscopy (UBM. Methods. Randomized patients underwent ab externo or ab interno scleral fixation of a PCIOL. Ultrasound biomicroscopy was performed 3 to 6 months postoperatively, to determine PCIOL centration, IOL distance to the iris at 12, 3, 6, and 9 hours, and haptics placement in relation to the ciliary sulcus. Results. Fifteen patients were enrolled in the study. The ab externo technique was used in 7 eyes (46.6% and the ab interno in 8 eyes (53.3%. In the ab externo technique, 14 haptics were located: 4 (28.57% in the ciliary sulcus; 2 (14.28% anterior to the sulcus; and 8 (57.14% posterior to the sulcus, 6 in the ciliary body and 2 posterior to the ciliary body. In the ab interno group, 4 haptics (25.0% were in the ciliary sulcus, 2 (12.50% anterior to the sulcus, and 10 (75.0% posterior to the sulcus, 4 in the ciliary body and 6 posterior to the ciliary body. Conclusions. Ab externo and ab interno scleral fixation techniques presented similar results in haptic placement. Ab externo technique presented higher vertical tilt when compared to the ab interno.

  19. Sutureless intrascleral intraocular lens fixation with lamellar dissection of scleral tunnel

    Science.gov (United States)

    Kawaji, Takahiro; Sato, Tomoki; Tanihara, Hidenobu

    2016-01-01

    Purpose To report the results of sutureless scleral fixation of a posterior chamber intraocular lens (IOL) by using our developed simple technique. Methods We retrospectively reviewed the medical records of 48 eyes of 47 patients who underwent sutureless intrascleral IOL fixation by using our modified technique. A 25-gauge microvitreoretinal knife was used to perform sclerotomies and create limbus-parallel scleral tunnels with lamellar dissection in which the haptics were fixed. Results The IOLs were fixed and centered well. The mean follow-up period was 26.7 months. Postoperative complications included smooth vitreous hemorrhage in four eyes (8.3%), cystoid macular edema in two eyes (4.2%), and iris capture of the IOL in two eyes (4.2%). No other complications, such as breakage of the IOL, spontaneous IOL dislocation, or retinal detachment, were detected during the follow-up period. Conclusion The lamellar dissection of the limbus-parallel scleral tunnel can simplify the forceps-assisted introduction of the haptics into the scleral tunnel, and this technique seemed to be safe. PMID:26869757

  20. Magnetic Nanoparticles as Intraocular Drug Delivery System to Target Retinal Pigmented Epithelium (RPE)

    Science.gov (United States)

    Giannaccini, Martina; Giannini, Marianna; Calatayud, M. Pilar; Goya, Gerardo F.; Cuschieri, Alfred; Dente, Luciana; Raffa, Vittoria

    2014-01-01

    One of the most challenging efforts in drug delivery is the targeting of the eye. The eye structure and barriers render this organ poorly permeable to drugs. Quite recently the entrance of nanoscience in ocular drug delivery has improved the penetration and half-life of drugs, especially in the anterior eye chamber, while targeting the posterior chamber is still an open issue. The retina and the retinal pigment epithelium/choroid tissues, located in the posterior eye chamber, are responsible for the majority of blindness both in childhood and adulthood. In the present study, we used magnetic nanoparticles (MNPs) as a nanotool for ocular drug delivery that is capable of specific localization in the retinal pigmented epithelium (RPE) layer. We demonstrate that, following intraocular injection in Xenopus embryos, MNPs localize specifically in RPE where they are retained for several days. The specificity of the localization did not depend on particle size and surface properties of the MNPs used in this work. Moreover, through similar experiments in zebrafish, we demonstrated that the targeting of RPE by the nanoparticles is not specific for the Xenopus species. PMID:24451140