WorldWideScience

Sample records for acquisition modes validation

  1. Validating Acquisition IS Integration Readiness with Drills

    DEFF Research Database (Denmark)

    Wynne, Peter J.

    2017-01-01

    To companies, mergers and acquisitions are important strategic tools, yet they often fail to deliver their expected value. Studies have shown the integration of information systems is a significant roadblock to the realisation of acquisition benefits, and for an IT department to be ready......), to understand how an IT department can use them to validate their integration plans. The paper presents a case study of two drills used to validate an IT department’s readiness to carry out acquisition IS integration, and suggests seven acquisition IS integration drill characteristics others could utilise when...

  2. The study on acquisition mode and reconstruction parameters of brain FDG PET images

    International Nuclear Information System (INIS)

    Zuo Chuantao; Liu Yongchang; Guan Yihui; Zhao Jun; Lin Xiangtong

    2001-01-01

    Objective: To evaluate the effect of acquisition mode on the brain PET images. Methods: After changing conditions and parameters, the authors got brain PET images of different acquisition modes, different emission counts, different transmission times; and compared with the reference images the impacts of different acquisition modes, different acquisition conditions were assessed. Results: Compared with 2D mode, much higher background and noise were observed on the reconstruction images of 3D mode, and the bottoms of the brain structure were not well displayed. But the middle part of brain structure displayed well in 2D and 3D mode without difference; the gray/white radioactivity ratios were 2.108 +- 0.183 and 2.286 +- 0.232 under 2D and 3D mode, respectively. The gray/white radioactivity ratios with different emission counts were 2.108 +- 0.183, 2.215 +- 0.158, 2.161 +- 0.176, respectively, there was no evident difference among them. With transmission counts increasing, the segmented image outline of Hoffman phantom and brain structure became clear and integral. Conclusions: Different acquisition modes, different emission counts and different transmission times are of certain impacts on brain FDG PET images, and it should be paid more attention in clinical practice

  3. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kai; Ma, Rui; Wang, Li Jun [Dept. of Radiology, Baotou Central Hospital, Baotou (China); Li, Li Gang; Chen, Jiu Hong [CT BM Clinic Marketing, Siemens Healthcare, Beijing (China)

    2012-11-15

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 {+-} 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 {+-} 0.306 [group A] vs. 1.084 {+-} 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 {+-} 0.16 mSv in group A and 7.1 {+-} 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  4. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    International Nuclear Information System (INIS)

    Sun, Kai; Ma, Rui; Wang, Li Jun; Li, Li Gang; Chen, Jiu Hong

    2012-01-01

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 ± 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 ± 0.306 [group A] vs. 1.084 ± 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 ± 0.16 mSv in group A and 7.1 ± 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  5. APNEA list mode data acquisition and real-time event processing

    Energy Technology Data Exchange (ETDEWEB)

    Hogle, R.A.; Miller, P. [GE Corporate Research & Development Center, Schenectady, NY (United States); Bramblett, R.L. [Lockheed Martin Specialty Components, Largo, FL (United States)

    1997-11-01

    The LMSC Active Passive Neutron Examinations and Assay (APNEA) Data Logger is a VME-based data acquisition system using commercial-off-the-shelf hardware with the application-specific software. It receives TTL inputs from eighty-eight {sup 3}He detector tubes and eight timing signals. Two data sets are generated concurrently for each acquisition session: (1) List Mode recording of all detector and timing signals, timestamped to 3 microsecond resolution; (2) Event Accumulations generated in real-time by counting events into short (tens of microseconds) and long (seconds) time bins following repetitive triggers. List Mode data sets can be post-processed to: (1) determine the optimum time bins for TRU assay of waste drums, (2) analyze a given data set in several ways to match different assay requirements and conditions and (3) confirm assay results by examining details of the raw data. Data Logger events are processed and timestamped by an array of 15 TMS320C40 DSPs and delivered to an embedded controller (PowerPC604) for interim disk storage. Three acquisition modes, corresponding to different trigger sources are provided. A standard network interface to a remote host system (Windows NT or SunOS) provides for system control, status, and transfer of previously acquired data. 6 figs.

  6. Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya

    2015-06-01

    The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Acquisition performance of LAPAN-A3/IPB multispectral imager in real-time mode of operation

    Science.gov (United States)

    Hakim, P. R.; Permala, R.; Jayani, A. P. S.

    2018-05-01

    LAPAN-A3/IPB satellite was launched in June 2016 and its multispectral imager has been producing Indonesian coverage images. In order to improve its support for remote sensing application, the imager should produce images with high quality and quantity. To improve the quantity of LAPAN-A3/IPB multispectral image captured, image acquisition could be executed in real-time mode from LAPAN ground station in Bogor when the satellite passes west Indonesia region. This research analyses the performance of LAPAN-A3/IPB multispectral imager acquisition in real-time mode, in terms of image quality and quantity, under assumption of several on-board and ground segment limitations. Results show that with real-time operation mode, LAPAN-A3/IPB multispectral imager could produce twice as much as image coverage compare to recorded mode. However, the images produced in real-time mode will have slightly degraded quality due to image compression process involved. Based on several analyses that have been done in this research, it is recommended to use real-time acquisition mode whenever it possible, unless for some circumstances that strictly not allow any quality degradation of the images produced.

  8. A DEMATEL-Based Framework for Identification of Causalities Among Internal and External Modes of Technology Acquisition

    OpenAIRE

    Farshid Mohamadnejad

    2014-01-01

    Technology acquisition plays a key role in the management of technology in industrial organizations. While there are ample theoretical and empirical researches on firm technology acquisition which are focused on the study of its dependence on other components of organization, the literature pays less attention to explore and analyze the inter-relatedness found in the main body of technology acquisition itself. Internal and external technology acquisitions are among the main substitute modes w...

  9. Effects of Video Caption Modes on English Listening Comprehension and Vocabulary Acquisition Using Handheld Devices

    Science.gov (United States)

    Hsu, Ching-Kun; Hwang, Gwo-Jen; Chang, Yu-Tzu; Chang, Chih-Kai

    2013-01-01

    This study investigates the effects of different display modes of video captions on mobile devices, including non-caption, full-caption, and target-word modes, on the English comprehension and vocabulary acquisition of fifth graders. During the one-month experiment, the status of the students' English listening comprehension and vocabulary…

  10. Acquisition versus greenfield foreign entry : diversification mode choice in Central and Eastern Europe

    NARCIS (Netherlands)

    Dikova, Desislava; Witteloostuijn, Adriaan van

    2005-01-01

    Departing from the traditional transaction cost approach in diversification mode literature, this study investigates the influence of experimental organizational learning on the choice between acquisition and a greenfield investment. We provide empirical support that prior experience with

  11. Validation of Schema Coping Inventory and Schema Mode Inventory in Adolescents

    NARCIS (Netherlands)

    van Wijk-Herbrink, M.F.; Roelofs, J.; Broers, N.J.; Rijkeboer, M.M.; Arntz, A.; Bernstein, D.P.

    2018-01-01

    This study investigated whether the schema therapy constructs of schema coping and schema modes have validity in adolescents. We examined the validity and reliability of the Schema Coping Inventory (SCI) and an 80-item version of the Schema Mode Inventory (SMI) in a mixed sample of adolescents.

  12. Estimating accidental coincidences for pixelated PET detectors and singles list-mode acquisition

    International Nuclear Information System (INIS)

    Rafecas, M.; Torres, I.; Spanoudaki, V.; McElroy, D.P.; Ziegler, S.I.

    2007-01-01

    We have studied the validity of random estimation techniques for various low energy thresholds (LETs) and single list-mode data sets in small animal PET. While a LET below 255 keV helps to increase the sensitivity, it also results in an increase of random coincidences and inter-crystal scatter (ICS). The study is carried out for MADPET-II, a dual-layer positron emission tomography (PET) scanner prototype consisting of LSO crystals read out individually by APDs. The data are acquired in singles list-mode format, and coincidences are computed post-acquisition. To estimate randoms, we have used the delayed coincidence window method (DW), and the singles rate model (SR). Various phantoms were simulated using GATE. For LETs under 255 keV, the number of random events R, estimated using the SR and the DW methods, is larger than the number of randoms which was directly computed from GATE simulations, and R(SR)>R(DW)>R(GATE). The higher the LET, the smaller the overestimation. For LETs >255 keV, R(DW)/R(GATE) ∼1. If scattered singles were excluded from the file, this discrepancy between R(DW or SR) and R(GATE) significantly diminished. This fact points out to ICS as the effect responsible for the mismatch, since for LETs lower than 255 keV, all singles related to an ICS event can be detected independently, thus altering the singles rate. Therefore, if low LETs are used, random estimation techniques should account for ICS

  13. Epid cine acquisition mode for in vivo dosimetry in dynamic arc radiation therapy

    International Nuclear Information System (INIS)

    Fidanzio, Andrea; Mameli, Alessandra; Placidi, Elisa; Greco, Francesca; Stimato, Gerardina; Gaudino, Diego; Ramella, Sara; D'Angelillo, Rolando; Cellini, Francesco; Trodella, Lucio; Cilla, Savino; Grimaldi, Luca; D'Onofrio, Guido; Azario, Luigi; Piermattei, Angelo

    2008-01-01

    In this paper the cine acquisition mode of an electronic portal imaging device (EPID) has been calibrated and tested to determine the in vivo dose for dynamic conformal arc radiation therapy (DCAT). The EPID cine acquisition mode, that allows a frame acquisition rate of one image every 1.66 s, was studied with a monitor unit rate equal to 100 UM/min. In these conditions good signal stability, ±1% (2SD) evaluated during three months, signal reproducibility within ±0.8% (2SD) and linearity with dose and dose rate within ±1% (2SD) were obtained. The transit signal, S t , (due to the transmitted beam below the phantom) measured by the EPID cine acquisition mode was used to determine, (i) a set of correlation functions, F(w,L), defined as the ratio between S t and the dose at half thickness, D m , measured in solid water phantoms of different thicknesses, w and with square fields of side L, (ii) a set of factors, f(d,L), that take into account the different X-ray scatter contribution from the phantom to the S t signal as a function of the variation, d, of the air gap between the phantom and the EPID. The reconstruction of the isocenter dose, D iso , for DCAT was obtained convolving the transit signal values, obtained at different gantry angles, with the respective reconstruction factors determined by a house-made software. The method was tested with cylindrical and anthropomorphic phantoms and the results show that the reconstructed D iso values can be obtained with an accuracy within ±2.5% in cylindrical phantom and within ±3.4% for anthropomorphic phantom. In conclusion, the transit dosimetry by EPID was assessed to be adequate to perform DCAT in vivo dosimetry, that is not realizable with the other traditional techniques. Moreover, the method proposed here could be implemented to supply in vivo dose values in real time

  14. Combining a Deconvolution and a Universal Library Search Algorithm for the Nontarget Analysis of Data-Independent Acquisition Mode Liquid Chromatography-High-Resolution Mass Spectrometry Results.

    Science.gov (United States)

    Samanipour, Saer; Reid, Malcolm J; Bæk, Kine; Thomas, Kevin V

    2018-04-17

    Nontarget analysis is considered one of the most comprehensive tools for the identification of unknown compounds in a complex sample analyzed via liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS). Due to the complexity of the data generated via LC-HRMS, the data-dependent acquisition mode, which produces the MS 2 spectra of a limited number of the precursor ions, has been one of the most common approaches used during nontarget screening. However, data-independent acquisition mode produces highly complex spectra that require proper deconvolution and library search algorithms. We have developed a deconvolution algorithm and a universal library search algorithm (ULSA) for the analysis of complex spectra generated via data-independent acquisition. These algorithms were validated and tested using both semisynthetic and real environmental data. A total of 6000 randomly selected spectra from MassBank were introduced across the total ion chromatograms of 15 sludge extracts at three levels of background complexity for the validation of the algorithms via semisynthetic data. The deconvolution algorithm successfully extracted more than 60% of the added ions in the analytical signal for 95% of processed spectra (i.e., 3 complexity levels multiplied by 6000 spectra). The ULSA ranked the correct spectra among the top three for more than 95% of cases. We further tested the algorithms with 5 wastewater effluent extracts for 59 artificial unknown analytes (i.e., their presence or absence was confirmed via target analysis). These algorithms did not produce any cases of false identifications while correctly identifying ∼70% of the total inquiries. The implications, capabilities, and the limitations of both algorithms are further discussed.

  15. Equilibrium radionuclide assessment of left ventricular ejection and filling. Comparison of list mode-and multigated frame-mode measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; McKenna, W.J.; Dickie, S.; Oakley, C.M.; Myers, M.J.; Lavender, J.P. (Royal Postgraduate Medical School, London (UK))

    1983-10-01

    The relationship as studied between radionuclide indices of left ventricular systolic and diastolic function acquired in conventional multigated frame-mode compared to list-mode in patients with sinus rhythm. The study showed that frame-mode and list-mode measurements of ejection and filling indices are not significantly different in these patients but that backward reformatting of data acquired in list-mode is necessary to measure the atrial contribution to LV stroke counts. It was concluded that valid measurements of left ventricular systolic ejection and diastolic filling can be made in patients in sinus rhythm using frame-mode acquisition with the exception of measurements of the contribution from atrial systole to stroke volume.

  16. Trade, Foreign Direct Investment or Acquisition: Optimal Entry Modes for Multinationals

    OpenAIRE

    Theo Eicher; Jong Woo Kang

    2004-01-01

    We examine multinationals’ optimal entry modes into foreign markets as a function of market size, FDI fixed costs, tariffs and transport costs. Our results highlight why large countries are more likely to attract acquisition investment, while intermediate-sized countries may be served predominantly through trade, even in the presence of high tariffs. Small countries are most likely to experience either FDI or no entry. We also show how these results vary with the competition intensity in th...

  17. Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Hara, Takanori; Urikura, Atsushi; Ichikawa, Katsuhiro; Hoshino, Takashi; Nishimaru, Eiji; Niwa, Shinji

    2016-04-01

    To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor (P) and gantry rotation time (R). The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of pitch factor of >1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 (R/P=0.285/1.5) and 0.074s (R/P=0.285/3.2), and the maximum TR values of the 64×0.5- and 160×0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 (R/P=0.275/1.375) and 0.195s (R/P=0.3/0.6), respectively. Because the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Reduction of radiation exposure in PET examinations by data acquisition in the 3D mode

    International Nuclear Information System (INIS)

    Brix, G.; Deutsches Krebsforschungszentrum; Adam, L.E.; Zaers, J.; Trojan, H.; Doll, J.; Bellemann, M.E.; Fachhochschule Jena; Nosske, D.

    1999-01-01

    Aim: Modern volume PET systems offer the possibility to measure without the shadowing effect of interplane septa (2D mode) and thus to detect coincident events between detectors on distant rings (3D mode). It was the aim of the present paper to characterize the count rate behaviour of a latest-generation whole-body PET system in the 2D and 3D mode as well as to discuss the consequences for the radiation hygiene of PET examinations with 2-[F-18]-fluoro-2-deoxyglucose (18-F-FDG). Methods: All experiments were performed with the PET system ECAT EXACT HR + . For 2D data acquisition, a collimator of thin tungsten septa was positioned in the field-of-view. The count rate behaviour of the scanner was evaluated in the 2D and 3D mode over a wide range of F-18 activity concentrations following the NEMA protocol. Moreover, PET images of the EEC whole-body phantom with different inserts were acquired in the 2D and 3D mode over a period of 15 min each. For the 3D measurement, the activity concentrations of the F-18 solution were only half of those used for the 2D measurement. Results: For the circular NEMA phantom (diameter=19.4 cm, length=19,0 cm), we observed an increase of the system sensitivity in the 3D mode by a factor of about 5 with respect to the 2D mode (27.7 vs. 5.7 cps/Bq/ml). The evaluation of the activity distributions of the EEC phantom reconstructed from the 3D data set revealed a superior image quality compared to the corresponding 2D images despite the fact that the activity concentrations were only half as high. Conclusion: By using the 3D data acquisition mode, it is possible to markedly reduce the amount of activity to be applied to the patient and nevertheless to improve image quality. In our experience, it is sufficient to administer an activity of 150-200 MBq for whole-body examinations with F-18-FDG, which results in an effective equivalent dose of 3 or 4 mSv, respectively. (orig.) [de

  19. Unattented mode monitoring of high resolution gamma-ray spectra

    International Nuclear Information System (INIS)

    Smith, B.G.R.; Van Dyck, P.; Debraix, P.

    1991-01-01

    An Isotope Monitoring System (IMS) for unattended spectrum acquisition is described. This consists of a simple low cost flexible software package running on a Compaq 80386 and controlling up to 4 Canberra Packard System 100 multi-channel analyzer (MCA) cards. The IMS permits the independent configuration of each of the 4 MCA cards for different monitoring cycles and for different spectrum acquisition cycles each being based upon different trigger criteria. In this way IMS is able to automatically identify events, time tag them, and acquire and store valid spectra corresponding to those event. An additional feature of IMS permits to run a Multigroup Analysis (MGA) software package for the determination of plutonium isotopic compositions in batch mode. One particular application is discussed which consists of 4 high resolution gamma-ray detector systems connected together to the IMS for unattended spectrum acquisition. The off-line batch mode analysis of the spectra using MGA is also discussed

  20. Variability of textural features in FDG PET images due to different acquisition modes and reconstruction parameters.

    Science.gov (United States)

    Galavis, Paulina E; Hollensen, Christian; Jallow, Ngoneh; Paliwal, Bhudatt; Jeraj, Robert

    2010-10-01

    Characterization of textural features (spatial distributions of image intensity levels) has been considered as a tool for automatic tumor segmentation. The purpose of this work is to study the variability of the textural features in PET images due to different acquisition modes and reconstruction parameters. Twenty patients with solid tumors underwent PET/CT scans on a GE Discovery VCT scanner, 45-60 minutes post-injection of 10 mCi of [(18)F]FDG. Scans were acquired in both 2D and 3D modes. For each acquisition the raw PET data was reconstructed using five different reconstruction parameters. Lesions were segmented on a default image using the threshold of 40% of maximum SUV. Fifty different texture features were calculated inside the tumors. The range of variations of the features were calculated with respect to the average value. Fifty textural features were classified based on the range of variation in three categories: small, intermediate and large variability. Features with small variability (range ≤ 5%) were entropy-first order, energy, maximal correlation coefficient (second order feature) and low-gray level run emphasis (high-order feature). The features with intermediate variability (10% ≤ range ≤ 25%) were entropy-GLCM, sum entropy, high gray level run emphsis, gray level non-uniformity, small number emphasis, and entropy-NGL. Forty remaining features presented large variations (range > 30%). Textural features such as entropy-first order, energy, maximal correlation coefficient, and low-gray level run emphasis exhibited small variations due to different acquisition modes and reconstruction parameters. Features with low level of variations are better candidates for reproducible tumor segmentation. Even though features such as contrast-NGTD, coarseness, homogeneity, and busyness have been previously used, our data indicated that these features presented large variations, therefore they could not be considered as a good candidates for tumor

  1. Variability of textural features in FDG PET images due to different acquisition modes and reconstruction parameters

    International Nuclear Information System (INIS)

    Galavis, Paulina E.; Jallow, Ngoneh; Paliwal, Bhudatt; Jeraj, Robert; Hollensen, Christian

    2010-01-01

    Background. Characterization of textural features (spatial distributions of image intensity levels) has been considered as a tool for automatic tumor segmentation. The purpose of this work is to study the variability of the textural features in PET images due to different acquisition modes and reconstruction parameters. Material and methods. Twenty patients with solid tumors underwent PET/CT scans on a GE Discovery VCT scanner, 45-60 minutes post-injection of 10 mCi of [ 18 F]FDG. Scans were acquired in both 2D and 3D modes. For each acquisition the raw PET data was reconstructed using five different reconstruction parameters. Lesions were segmented on a default image using the threshold of 40% of maximum SUV. Fifty different texture features were calculated inside the tumors. The range of variations of the features were calculated with respect to the average value. Results. Fifty textural features were classified based on the range of variation in three categories: small, intermediate and large variability. Features with small variability (range = 5%) were entropy-first order, energy, maximal correlation coefficient (second order feature) and low-gray level run emphasis (high-order feature). The features with intermediate variability (10% = range = 25%) were entropy-GLCM, sum entropy, high gray level run emphasis, gray level non-uniformity, small number emphasis, and entropy-NGL. Forty remaining features presented large variations (range > 30%). Conclusion. Textural features such as entropy-first order, energy, maximal correlation coefficient, and low-gray level run emphasis exhibited small variations due to different acquisition modes and reconstruction parameters. Features with low level of variations are better candidates for reproducible tumor segmentation. Even though features such as contrast-NGTD, coarseness, homogeneity, and busyness have been previously used, our data indicated that these features presented large variations, therefore they could not be

  2. MSCT versus CBCT: evaluation of high-resolution acquisition modes for dento-maxillary and skull-base imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dillenseger, Jean-Philippe; Goetz, Christian [Hopitaux Universitaires de Strasbourg, Imagerie Preclinique-UF6237, Pole d' imagerie, Strasbourg (France); Universite de Strasbourg, Icube, equipe MMB, CNRS, Strasbourg (France); Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Matern, Jean-Francois [Hopitaux Universitaires de Strasbourg, Imagerie Preclinique-UF6237, Pole d' imagerie, Strasbourg (France); Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Gros, Catherine-Isabelle; Bornert, Fabien [Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Universite de Strasbourg, Faculte de Chirurgie Dentaire, Strasbourg (France); Le Minor, Jean-Marie [Universite de Strasbourg, Icube, equipe MMB, CNRS, Strasbourg (France); Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Universite de Strasbourg, Institut d' Anatomie Normale, Strasbourg (France); Constantinesco, Andre [Hopitaux Universitaires de Strasbourg, Imagerie Preclinique-UF6237, Pole d' imagerie, Strasbourg (France); Choquet, Philippe [Hopitaux Universitaires de Strasbourg, Imagerie Preclinique-UF6237, Pole d' imagerie, Strasbourg (France); Universite de Strasbourg, Icube, equipe MMB, CNRS, Strasbourg (France); Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Hopital de Hautepierre, Imagerie Preclinique, Biophysique et Medecine Nucleaire, Strasbourg Cedex (France)

    2014-09-24

    Our aim was to conduct a quantitative and qualitative evaluation of high-resolution skull-bone imaging for dentistry and otolaryngology using different architectures of recent X-ray computed tomography systems. Three multi-slice computed tomography (MSCT) systems and one Cone-beam computed tomography (CBCT) system were used in this study. All apparatuses were tested with installed acquisition modes and proprietary reconstruction software enabling high-resolution bone imaging. Quantitative analyses were performed with small fields of view with the preclinical vmCT phantom, which permits to measure spatial resolution, geometrical accuracy, linearity and homogeneity. Ten operators performed visual qualitative analyses on the vmCT phantom images, and on dry human skull images. Quantitative analysis showed no significant differences between protocols in terms of linearity and geometric accuracy. All MSCT systems present a better homogeneity than the CBCT. Both quantitative and visual analyses demonstrate that CBCT acquisitions are not better than the collimated helical MSCT mode. Our results demonstrate that current high-resolution MSCT protocols could exceed the performance of a previous generation CBCT system for spatial resolution and image homogeneity. (orig.)

  3. MSCT versus CBCT: evaluation of high-resolution acquisition modes for dento-maxillary and skull-base imaging

    International Nuclear Information System (INIS)

    Dillenseger, Jean-Philippe; Goetz, Christian; Matern, Jean-Francois; Gros, Catherine-Isabelle; Bornert, Fabien; Le Minor, Jean-Marie; Constantinesco, Andre; Choquet, Philippe

    2015-01-01

    Our aim was to conduct a quantitative and qualitative evaluation of high-resolution skull-bone imaging for dentistry and otolaryngology using different architectures of recent X-ray computed tomography systems. Three multi-slice computed tomography (MSCT) systems and one Cone-beam computed tomography (CBCT) system were used in this study. All apparatuses were tested with installed acquisition modes and proprietary reconstruction software enabling high-resolution bone imaging. Quantitative analyses were performed with small fields of view with the preclinical vmCT phantom, which permits to measure spatial resolution, geometrical accuracy, linearity and homogeneity. Ten operators performed visual qualitative analyses on the vmCT phantom images, and on dry human skull images. Quantitative analysis showed no significant differences between protocols in terms of linearity and geometric accuracy. All MSCT systems present a better homogeneity than the CBCT. Both quantitative and visual analyses demonstrate that CBCT acquisitions are not better than the collimated helical MSCT mode. Our results demonstrate that current high-resolution MSCT protocols could exceed the performance of a previous generation CBCT system for spatial resolution and image homogeneity. (orig.)

  4. Comparison of detectability in step-and-shoot mode and continuous mode digital tomosynthesis systems

    Science.gov (United States)

    Lee, Changwoo; Han, Minah; Baek, Jongduk

    2017-03-01

    Digital tomosynthesis system has been widely used in chest, dental, and breast imaging. Since the digital tomosynthesis system provides volumetric images from multiple projection data, structural noise inherent in X-ray radiograph can be reduced, and thus signal detection performance is improved. Currently, tomosynthesis system uses two data acquisition modes: step-and-shoot mode and continuous mode. Several studies have been conducted to compare the system performance of two acquisition modes with respect to spatial resolution and contrast. In this work, we focus on signal detectability in step-and-shoot mode and continuous mode. For evaluation, uniform background is considered, and eight spherical objects with diameters of 0.5, 0.8, 1, 2, 3, 5, 8, 10 mm are used as signals. Projection data with and without spherical objects are acquired in step-and-shoot mode and continuous mode, respectively, and quantum noise are added. Then, noisy projection data are reconstructed by FDK algorithm. To compare the detection performance of two acquisition modes, we calculate task signal-to-noise ratio (SNR) of channelized Hotelling observer with Laguerre-Gauss channels for each spherical object. While the task-SNR values of two acquisition modes are similar for spherical objects larger than 1 mm diameter, step-and-shoot mode yields higher detectability for small signal sizes. The main reason of this behavior is that small signal is more affected by X-ray tube motion blur than large signal. Our results indicate that it is beneficial to use step-and-shoot data acquisition mode to improve the detectability of small signals (i.e., less than 1 mm diameter) in digital tomosynthesis systems.

  5. Sialoglycans in protozoal diseases: their detection, modes of acquisition and emerging biological roles.

    Science.gov (United States)

    Chava, Anil K; Bandyopadhyay, Sumi; Chatterjee, Mitali; Mandal, Chitra

    2004-01-01

    Protozoan parasites including Plasmodia, Leishmania, Trypanosoma, Entamoeba, Trichomonas and others cause diseases in humans and domestic livestock having far-reaching socio-economic implications. They show remarkable propensity to survive within hostile environments encountered during their life cycle, and the identification of molecules that enable them to survive in such milieu is a subject of intense research. Currently available knowledge of the parasite cell surface architecture and biochemistry indicates that sialic acid and its principle derivatives are major components of the glycocalyx and assist the parasite to interact with its external environment through functions ranging from parasite survival, infectivity and host-cell recognition. This review highlights the present state of knowledge with regard to parasite sialobiology with an emphasis on its mode(s) of acquisition and their emerging biological roles, notably as an anti-recognition molecule thereby aiding the pathogen to evade host defense mechanisms.

  6. Content validation: clarity/relevance, reliability and internal consistency of enunciative signs of language acquisition.

    Science.gov (United States)

    Crestani, Anelise Henrich; Moraes, Anaelena Bragança de; Souza, Ana Paula Ramos de

    2017-08-10

    To analyze the results of the validation of building enunciative signs of language acquisition for children aged 3 to 12 months. The signs were built based on mechanisms of language acquisition in an enunciative perspective and on clinical experience with language disorders. The signs were submitted to judgment of clarity and relevance by a sample of six experts, doctors in linguistic in with knowledge of psycholinguistics and language clinic. In the validation of reliability, two judges/evaluators helped to implement the instruments in videos of 20% of the total sample of mother-infant dyads using the inter-evaluator method. The method known as internal consistency was applied to the total sample, which consisted of 94 mother-infant dyads to the contents of the Phase 1 (3-6 months) and 61 mother-infant dyads to the contents of Phase 2 (7 to 12 months). The data were collected through the analysis of mother-infant interaction based on filming of dyads and application of the parameters to be validated according to the child's age. Data were organized in a spreadsheet and then converted to computer applications for statistical analysis. The judgments of clarity/relevance indicated no modifications to be made in the instruments. The reliability test showed an almost perfect agreement between judges (0.8 ≤ Kappa ≥ 1.0); only the item 2 of Phase 1 showed substantial agreement (0.6 ≤ Kappa ≥ 0.79). The internal consistency for Phase 1 had alpha = 0.84, and Phase 2, alpha = 0.74. This demonstrates the reliability of the instruments. The results suggest adequacy as to content validity of the instruments created for both age groups, demonstrating the relevance of the content of enunciative signs of language acquisition.

  7. Comparison of continuous with step and shoot acquisition in SPECT scanning

    International Nuclear Information System (INIS)

    McCarthy, L.; Cotterill, T.; Chu, J.M.G.

    1998-01-01

    Full text: Following the recent advent of continuous acquisition for performing SPECT scanning, it was decided to compare the commonly used Step and Shoot mode of acquisition with the new continuous acquisition mode. The aim of the study is to assess any difference in resolution from the resulting images acquired using the two modes of acquisition. Sequential series of studies were performed on a SPECT phantom using both modes of acquisition. Separate sets of data were collected for both high resolution parallel hole and ultra high resolution fan beam collimators. Clinical data was collected on patients undergoing routine gallium, 99m Tc-MDP bone and 99m Tc-HMPAO brain studies. Separate sequential acquisition in both modes were collected for each patient. The sequence of collection was also alternated. Reconstruction was performed utilising the same parameters for each acquisition. The reconstructed data were assessed visually by blinded observers to detect differences in resolution and image quality. No significant difference in the studies collected by either acquisition modes were detected. The time saved by continuous acquisition could be an advantage

  8. Extended data acquisition support at GSI

    International Nuclear Information System (INIS)

    Marinescu, D.C.; Busch, F.; Hultzsch, H.; Lowsky, J.; Richter, M.

    1984-01-01

    The Experiment Data Acquisition and Analysis System (EDAS) of GSI, designed to support the data processing associated with nuclear physics experiments, provides three modes of operation: real-time, interactive replay and batch replay. The real-time mode is used for data acquisition and data analysis during an experiment performed at the heavy ion accelerator at GSI. An experiment may be performed either in Stand Alone Mode, using only the Experiment Computers, or in Extended Mode using all computing resources available. The Extended Mode combines the advantages of the real-time response of a dedicated minicomputer with the availability of computing resources in a large computing environment. This paper first gives an overview of EDAS and presents the GSI High Speed Data Acquisition Network. Data Acquisition Modes and the Extended Mode are then introduced. The structure of the system components, their implementation and the functions pertinent to the Extended Mode are presented. The control functions of the Experiment Computer sub-system are discussed in detail. Two aspects of the design of the sub-system running on the mainframe are stressed, namely the use of a multi-user installation for real-time processing and the use of a high level programming language, PL/I, as an implementation language for a system which uses parallel processing. The experience accumulated is summarized in a number of conclusions

  9. A method to synchronize signals from multiple patient monitoring devices through a single input channel for inclusion in list-mode acquisitions

    International Nuclear Information System (INIS)

    O’Connor, J. Michael; Pretorius, P. Hendrik; Johnson, Karen; King, Michael A.

    2013-01-01

    Purpose: This technical note documents a method that the authors developed for combining a signal to synchronize a patient-monitoring device with a second physiological signal for inclusion into list-mode acquisition. Our specific application requires synchronizing an external patient motion-tracking system with a medical imaging system by multiplexing the tracking input with the ECG input. The authors believe that their methodology can be adapted for use in a variety of medical imaging modalities including single photon emission computed tomography (SPECT) and positron emission tomography (PET). Methods: The authors insert a unique pulse sequence into a single physiological input channel. This sequence is then recorded in the list-mode acquisition along with the R-wave pulse used for ECG gating. The specific form of our pulse sequence allows for recognition of the time point being synchronized even when portions of the pulse sequence are lost due to collisions with R-wave pulses. This was achieved by altering our software used in binning the list-mode data to recognize even a portion of our pulse sequence. Limitations on heart rates at which our pulse sequence could be reliably detected were investigated by simulating the mixing of the two signals as a function of heart rate and time point during the cardiac cycle at which our pulse sequence is mixed with the cardiac signal. Results: The authors have successfully achieved accurate temporal synchronization of our motion-tracking system with acquisition of SPECT projections used in 17 recent clinical research cases. In our simulation analysis the authors determined that synchronization to enable compensation for body and respiratory motion could be achieved for heart rates up to 125 beats-per-minute (bpm). Conclusions: Synchronization of list-mode acquisition with external patient monitoring devices such as those employed in motion-tracking can reliably be achieved using a simple method that can be implemented using

  10. A method to synchronize signals from multiple patient monitoring devices through a single input channel for inclusion in list-mode acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    O’Connor, J. Michael; Pretorius, P. Hendrik; Johnson, Karen; King, Michael A., E-mail: Michael.King@umassmed.edu [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States)

    2013-12-15

    Purpose: This technical note documents a method that the authors developed for combining a signal to synchronize a patient-monitoring device with a second physiological signal for inclusion into list-mode acquisition. Our specific application requires synchronizing an external patient motion-tracking system with a medical imaging system by multiplexing the tracking input with the ECG input. The authors believe that their methodology can be adapted for use in a variety of medical imaging modalities including single photon emission computed tomography (SPECT) and positron emission tomography (PET). Methods: The authors insert a unique pulse sequence into a single physiological input channel. This sequence is then recorded in the list-mode acquisition along with the R-wave pulse used for ECG gating. The specific form of our pulse sequence allows for recognition of the time point being synchronized even when portions of the pulse sequence are lost due to collisions with R-wave pulses. This was achieved by altering our software used in binning the list-mode data to recognize even a portion of our pulse sequence. Limitations on heart rates at which our pulse sequence could be reliably detected were investigated by simulating the mixing of the two signals as a function of heart rate and time point during the cardiac cycle at which our pulse sequence is mixed with the cardiac signal. Results: The authors have successfully achieved accurate temporal synchronization of our motion-tracking system with acquisition of SPECT projections used in 17 recent clinical research cases. In our simulation analysis the authors determined that synchronization to enable compensation for body and respiratory motion could be achieved for heart rates up to 125 beats-per-minute (bpm). Conclusions: Synchronization of list-mode acquisition with external patient monitoring devices such as those employed in motion-tracking can reliably be achieved using a simple method that can be implemented using

  11. Comparison of screening performance metrics and patient dose of two mammographic image acquisition modes in the Danish National Breast Cancer Screening Programme

    DEFF Research Database (Denmark)

    Abdi, Ahmed Jibril; Fieselmann, Andreas; Pfaff, Heiderose

    2018-01-01

    Introduction: In this study, screening performance metrics and radiation dose were compared for two image acquisition modes for breast cancer screening with MAMMOMAT Inspiration (Siemens Healthcare GmbH, Forchheim, Germany). This mammography system can operate without an anti-scatter grid in place...... compared to grid-based screening. The specificity was 98.11% (95% confidence interval (CI) from 97.93% to 98.29%) and 97.96% (95% CI from 97.84% to 98.09%) for screening with grid-less acquisition and grid-based acquisition, respectively. The cancer detection rate as a measure for sensitivity was equal (0...

  12. SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID

    Energy Technology Data Exchange (ETDEWEB)

    Bawazeer, O; Deb, P [RMIT University, Melbourne, VIC (Australia); Sarasanandarajah, S [Peter MacCallum Cancer Institute, Melbourne, Victoria (Australia); Herath, S; Kron, T [Peter MacCallum Cancer Institute, Melbourne, VIC (Australia)

    2016-06-15

    Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest of the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.

  13. SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID

    International Nuclear Information System (INIS)

    Bawazeer, O; Deb, P; Sarasanandarajah, S; Herath, S; Kron, T

    2016-01-01

    Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest of the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.

  14. Daily organ tracking in intensity-modulated radiotherapy of prostate cancer using an electronic portal imaging device with a dose saving acquisition mode

    International Nuclear Information System (INIS)

    Vetterli, Daniel; Thalmann, Sandrine; Behrensmeier, Frank; Kemmerling, Ludger; Born, Ernst J.; Mini, Roberto; Greiner, Richard H.; Aebersold, Daniel M.

    2006-01-01

    Background and purpose: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. Patients and methods: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. Results: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to ≤0.3 mm. Conclusions: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory

  15. Failure mode and effects analysis outputs: are they valid?

    Science.gov (United States)

    Shebl, Nada Atef; Franklin, Bryony Dean; Barber, Nick

    2012-06-10

    Failure Mode and Effects Analysis (FMEA) is a prospective risk assessment tool that has been widely used within the aerospace and automotive industries and has been utilised within healthcare since the early 1990s. The aim of this study was to explore the validity of FMEA outputs within a hospital setting in the United Kingdom. Two multidisciplinary teams each conducted an FMEA for the use of vancomycin and gentamicin. Four different validity tests were conducted: Face validity: by comparing the FMEA participants' mapped processes with observational work. Content validity: by presenting the FMEA findings to other healthcare professionals. Criterion validity: by comparing the FMEA findings with data reported on the trust's incident report database. Construct validity: by exploring the relevant mathematical theories involved in calculating the FMEA risk priority number. Face validity was positive as the researcher documented the same processes of care as mapped by the FMEA participants. However, other healthcare professionals identified potential failures missed by the FMEA teams. Furthermore, the FMEA groups failed to include failures related to omitted doses; yet these were the failures most commonly reported in the trust's incident database. Calculating the RPN by multiplying severity, probability and detectability scores was deemed invalid because it is based on calculations that breach the mathematical properties of the scales used. There are significant methodological challenges in validating FMEA. It is a useful tool to aid multidisciplinary groups in mapping and understanding a process of care; however, the results of our study cast doubt on its validity. FMEA teams are likely to need different sources of information, besides their personal experience and knowledge, to identify potential failures. As for FMEA's methodology for scoring failures, there were discrepancies between the teams' estimates and similar incidents reported on the trust's incident

  16. A Mode Propagation Database Suitable for Code Validation Utilizing the NASA Glenn Advanced Noise Control Fan and Artificial Sources

    Science.gov (United States)

    Sutliff, Daniel L.

    2014-01-01

    The NASA Glenn Research Center's Advanced Noise Control Fan (ANCF) was developed in the early 1990s to provide a convenient test bed to measure and understand fan-generated acoustics, duct propagation, and radiation to the farfield. A series of tests were performed primarily for the use of code validation and tool validation. Rotating Rake mode measurements were acquired for parametric sets of: (i) mode blockage, (ii) liner insertion loss, (iii) short ducts, and (iv) mode reflection.

  17. Validation of CryoSat-2 Performance over Arctic Sea Ice

    DEFF Research Database (Denmark)

    Di Bella, Alessandro; Skourup, Henriette; Bouffard, J.

    The main objective of this work is to validate CryoSat-2 (CS2) SARIn performance over sea ice by use of airborne laser altimetry data obtained during the CryoVEx 2012 campaign. A study by [1] has shown that the extra information from the CS2 SARIn mode increases the number of valid sea surface...... to validate the sea ice freeboard obtained by processing CS2 SARIn level 1b waveforms. The possible reduction in the random freeboard uncertainty is investigated comparing two scenarios, i.e. a SAR-like and a SARIn acquisition. It is observed that using the extra phase information, CS2 is able to detect leads...... height estimates which are usually discarded in the SAR mode due to snagging of the radar signal. As the number of valid detected leads increases, the uncertainty of the freeboard heights decreases. In this study, the snow freeboard heights estimated using data from the airborne laser scanner are used...

  18. Dynamic arrythmia filtration for gated blood pool imaging: Validation against list - Mode technique

    International Nuclear Information System (INIS)

    Juni, J.E.; Wallis, J.; Rocchini, A.; Wu-Connolly, L.

    1985-01-01

    Normal resting heart rate variation distort the diastolic portions of time-activity curves (TACs) generated from gated blood pool (GBP) images. This alters calculated measures of diastolic function e.g. peak filling rate (PFR). The authors compared diastolic filling parameters obtained by two methods of arrythmia removal, list-mode (LM) acquisition and a new approach, dynamic arrythima filtration (DAF). LM acquisition techniques reject beats of unusual cycle length, thus reducing the TAC distortions caused by heart rate variation but is time consuming and requires large amounts of disk storage. In DAF systems data is evaluated for cycle length in real-time and accepted or rejected immediately according to preset, operator determined cycle-length criteria, thus eliminating the need for post-processing of data and for large mass data storage. The authors prospectively determined EF, time to end-systole (TES), PFR, ad TPFR on 25 GBP patients. Camera and ECG data were sent simultaneously to 2 computers. One acquired data via LM and the other by DAF. Fluctuations in heart rate during GBP acquisition may cause errors in calculation of filling parameters. Both LM and DAF remove cycles of unusual length. DAF is less time consuming and technically demanding than LM and provides results which correlate closely with those obtained by LM

  19. Uncertainty Reduction of Arctic Sea Ice Freeboard from CryoSat-2 Interferometric Mode

    DEFF Research Database (Denmark)

    Di Bella, A.; Skourup, H.; Bouffard, J.

    2018-01-01

    increases, the uncertainty of the freeboard heights decreases. In this study, the freeboard heights estimated by processing CS2 SARIn level 1b waveforms are validated using the information from airborne laser and radar altimetry as well as snow radar measurements acquired during the CryoVEx 2012......Abstract A study by Armitage and Davidson (2014) has shown that the extra information from the CryoSat-2 (CS2) SARIn mode increases the number of valid sea surface height estimates which are usually discarded in the SAR mode due to snagging of the radar signal. As the number of valid detected leads...... and Operation IceBridge 2012 campaigns, respectively. The possible reduction in the random freeboard uncertainty is investigated comparing two scenarios, i.e. a SAR-like and a SARIn acquisition. A very good agreement is found between average airborne and satellite radar freeboards although, at the CS2 footprint...

  20. Wide-range bipolar pulse conductance instrument employing current and voltage modes with sampled or integrated signal acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Calhoun, R K; Holler, F J [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Geiger, jr, R F; Nieman, T A [Illinois Univ., Urbana, IL (United States). Dept. of Chemistry; Caserta, K J [Procter and Gamble Co., Cincinnati, OH (United States)

    1991-11-05

    An instrument for measuring solution conductance using the bipolar pulse technique is described. The instrument is capable of measuring conductances in the range of 5x10{sup -9}-10{Omega}{sup -1} with 1% accuracy or better in as little as 32 {mu}s. Accuracy of 0.001-0.01% is achievable over the range 1x10{sup -6}-1{Omega}{sup -1}. Circuitry and software are described that allow the instrument to adjust automatically the pulse height, pulse duration, excitation mode (current or voltage pulse) and data acquisition mode (sampled or integrated) to acquire data of optimum accuracy and precision. The urease-catalyzed decomposition of urea is used to illustrate the versality of the instrument, and other applications are cited. (author). 60 refs.; 7 figs.; 2 tabs.

  1. Failure mode and effects analysis outputs: are they valid?

    Directory of Open Access Journals (Sweden)

    Shebl Nada

    2012-06-01

    Full Text Available Abstract Background Failure Mode and Effects Analysis (FMEA is a prospective risk assessment tool that has been widely used within the aerospace and automotive industries and has been utilised within healthcare since the early 1990s. The aim of this study was to explore the validity of FMEA outputs within a hospital setting in the United Kingdom. Methods Two multidisciplinary teams each conducted an FMEA for the use of vancomycin and gentamicin. Four different validity tests were conducted: · Face validity: by comparing the FMEA participants’ mapped processes with observational work. · Content validity: by presenting the FMEA findings to other healthcare professionals. · Criterion validity: by comparing the FMEA findings with data reported on the trust’s incident report database. · Construct validity: by exploring the relevant mathematical theories involved in calculating the FMEA risk priority number. Results Face validity was positive as the researcher documented the same processes of care as mapped by the FMEA participants. However, other healthcare professionals identified potential failures missed by the FMEA teams. Furthermore, the FMEA groups failed to include failures related to omitted doses; yet these were the failures most commonly reported in the trust’s incident database. Calculating the RPN by multiplying severity, probability and detectability scores was deemed invalid because it is based on calculations that breach the mathematical properties of the scales used. Conclusion There are significant methodological challenges in validating FMEA. It is a useful tool to aid multidisciplinary groups in mapping and understanding a process of care; however, the results of our study cast doubt on its validity. FMEA teams are likely to need different sources of information, besides their personal experience and knowledge, to identify potential failures. As for FMEA’s methodology for scoring failures, there were discrepancies

  2. Image quality and dose analysis for a PA chest X-ray: Comparison between AEC mode acquisition and manual mode using the 10 kVp ‘rule’

    International Nuclear Information System (INIS)

    Reis, Cláudia; Gonçalves, João; Klompmaker, Corrie; Bárbara, Ana Rita; Bloor, Chloe; Hegarty, Ryan; Lagrange, Tania; Temming, Noëlle; Sønnesyn, Mathilde; Røkeness, Henriette; Yamasathien, Amandine; Hogg, Peter

    2014-01-01

    Purpose: To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method: 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results: Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion: In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality

  3. Factorial Structure and Preliminary Validation of the Schema Mode Inventory for Eating Disorders (SMI-ED

    Directory of Open Access Journals (Sweden)

    Susan G. Simpson

    2018-04-01

    Full Text Available Objective: The aim of this study was to examine the psychometric properties and factorial structure of the Schema Mode Inventory for Eating Disorders (SMI-ED in a disordered eating population.Method: 573 participants with disordered eating patterns as measured by the Eating Disorder Examination Questionnaire (EDE-Q completed the 190-item adapted version of the Schema Mode Inventory (SMI. The new SMI-ED was developed by clinicians/researchers specializing in the treatment of eating disorders, through combining items from the original SMI with a set of additional questions specifically representative of the eating disorder population. Psychometric testing included Confirmatory Factor Analysis (CFA and internal consistency (Cronbach's α. Multivariate Analyses of Covariance (MANCOVA was also run to test statistical differences between the EDE-Q subscales on the SMI-ED modes, while controlling for possible confounding variables.Results: Factorial analysis confirmed an acceptable 16-related-factors solution for the SMI-ED, thus providing preliminary evidence for the adequate validity of the new measure based on internal structure. Concurrent validity was also established through moderate to high correlations on the modes most relevant to eating disorders with EDE-Q subscales. This study represents the first step in creating a psychometrically sound instrument for measuring schema modes in eating disorders, and provides greater insight into the relevant schema modes within this population.Conclusion: This research represents an important preliminary step toward understanding and labeling the schema mode model for this clinical group. Findings from the psychometric evaluation of SMI-ED suggest that this is a useful tool which may further assist in the measurement and conceptualization of schema modes in this population.

  4. Factorial Structure and Preliminary Validation of the Schema Mode Inventory for Eating Disorders (SMI-ED).

    Science.gov (United States)

    Simpson, Susan G; Pietrabissa, Giada; Rossi, Alessandro; Seychell, Tahnee; Manzoni, Gian Mauro; Munro, Calum; Nesci, Julian B; Castelnuovo, Gianluca

    2018-01-01

    Objective: The aim of this study was to examine the psychometric properties and factorial structure of the Schema Mode Inventory for Eating Disorders (SMI-ED) in a disordered eating population. Method: 573 participants with disordered eating patterns as measured by the Eating Disorder Examination Questionnaire (EDE-Q) completed the 190-item adapted version of the Schema Mode Inventory (SMI). The new SMI-ED was developed by clinicians/researchers specializing in the treatment of eating disorders, through combining items from the original SMI with a set of additional questions specifically representative of the eating disorder population. Psychometric testing included Confirmatory Factor Analysis (CFA) and internal consistency (Cronbach's α). Multivariate Analyses of Covariance (MANCOVA) was also run to test statistical differences between the EDE-Q subscales on the SMI-ED modes, while controlling for possible confounding variables. Results: Factorial analysis confirmed an acceptable 16-related-factors solution for the SMI-ED, thus providing preliminary evidence for the adequate validity of the new measure based on internal structure. Concurrent validity was also established through moderate to high correlations on the modes most relevant to eating disorders with EDE-Q subscales. This study represents the first step in creating a psychometrically sound instrument for measuring schema modes in eating disorders, and provides greater insight into the relevant schema modes within this population. Conclusion: This research represents an important preliminary step toward understanding and labeling the schema mode model for this clinical group. Findings from the psychometric evaluation of SMI-ED suggest that this is a useful tool which may further assist in the measurement and conceptualization of schema modes in this population.

  5. Factorial Structure and Preliminary Validation of the Schema Mode Inventory for Eating Disorders (SMI-ED)

    Science.gov (United States)

    Simpson, Susan G.; Pietrabissa, Giada; Rossi, Alessandro; Seychell, Tahnee; Manzoni, Gian Mauro; Munro, Calum; Nesci, Julian B.; Castelnuovo, Gianluca

    2018-01-01

    Objective: The aim of this study was to examine the psychometric properties and factorial structure of the Schema Mode Inventory for Eating Disorders (SMI-ED) in a disordered eating population. Method: 573 participants with disordered eating patterns as measured by the Eating Disorder Examination Questionnaire (EDE-Q) completed the 190-item adapted version of the Schema Mode Inventory (SMI). The new SMI-ED was developed by clinicians/researchers specializing in the treatment of eating disorders, through combining items from the original SMI with a set of additional questions specifically representative of the eating disorder population. Psychometric testing included Confirmatory Factor Analysis (CFA) and internal consistency (Cronbach's α). Multivariate Analyses of Covariance (MANCOVA) was also run to test statistical differences between the EDE-Q subscales on the SMI-ED modes, while controlling for possible confounding variables. Results: Factorial analysis confirmed an acceptable 16-related-factors solution for the SMI-ED, thus providing preliminary evidence for the adequate validity of the new measure based on internal structure. Concurrent validity was also established through moderate to high correlations on the modes most relevant to eating disorders with EDE-Q subscales. This study represents the first step in creating a psychometrically sound instrument for measuring schema modes in eating disorders, and provides greater insight into the relevant schema modes within this population. Conclusion: This research represents an important preliminary step toward understanding and labeling the schema mode model for this clinical group. Findings from the psychometric evaluation of SMI-ED suggest that this is a useful tool which may further assist in the measurement and conceptualization of schema modes in this population. PMID:29740379

  6. Continued Data Acquisition Development

    Energy Technology Data Exchange (ETDEWEB)

    Schwellenbach, David [National Security Technologies, LLC. (NSTec), Mercury, NV (United States)

    2017-11-27

    This task focused on improving techniques for integrating data acquisition of secondary particles correlated in time with detected cosmic-ray muons. Scintillation detectors with Pulse Shape Discrimination (PSD) capability show the most promise as a detector technology based on work in FY13. Typically PSD parameters are determined prior to an experiment and the results are based on these parameters. By saving data in list mode, including the fully digitized waveform, any experiment can effectively be replayed to adjust PSD and other parameters for the best data capture. List mode requires time synchronization of two independent data acquisitions (DAQ) systems: the muon tracker and the particle detector system. Techniques to synchronize these systems were studied. Two basic techniques were identified: real time mode and sequential mode. Real time mode is the preferred system but has proven to be a significant challenge since two FPGA systems with different clocking parameters must be synchronized. Sequential processing is expected to work with virtually any DAQ but requires more post processing to extract the data.

  7. Program design of data acquisition in Windows

    International Nuclear Information System (INIS)

    Cai Jianxin; Yan Huawen

    2004-01-01

    Several methods for the design of data acquisition program based on Microsoft Windows are introduced. Then their respective advantages and disadvantages are totally analyzed. At the same time, the data acquisition modes applicable to each method are also pointed out. It is convenient for data acquisition programmers to develop data acquisition systems. (authors)

  8. Accelerated territorial arterial spin labeling based on shared rotating control acquisition: an observer study for validation

    International Nuclear Information System (INIS)

    Kamano, Hironori; Yoshiura, Takashi; Hiwatashi, Akio; Yamashita, Koji; Takayama, Yukihisa; Nagao, Eiki; Sagiyama, Koji; Honda, Hiroshi; Zimine, Ivan

    2012-01-01

    Shared rotating control acquisition can shorten the imaging time of territorial arterial spin labeling (tASL) by 33% compared with the normal control acquisition scheme but potentially results in an inaccurate estimate of vascular territories due to imperfect magnetization transfer compensation. Our purpose was to validate the accuracy of the shared rotating control acquisition method in evaluation of vascular territories. Twenty-four patients underwent tASL at a 3.0-T MRI with the conventional normal control acquisition method. Composite vascular territory maps, in which the blood flows from the right and left internal carotid arteries and the posterior circulation were encoded in red-green-blue, were generated as a normal averaged control-label scheme and as a simulated shared rotating control scheme. Two observers independently reported the most dominant territorial flow in 26 brain regions corresponding to the arterial segments at three post-labeling time points. Inter-reader and inter-method agreements were analyzed using κ statistics. Overall inter-reader agreements were excellent for both the normal control and the shared rotating control methods (κ = 0.98, respectively). Overall inter-method agreement was also excellent (κ = 0.98), although relatively low agreement was noted in the bilateral posterior cerebral artery territories (κ = 0.79 to 0.93). Our results suggested that tASL using shared rotating control acquisition can provide information on the vascular territories comparable to that obtained using the normal control acquisition while substantially shortening the imaging time. (orig.)

  9. Development and validation of a smartphone heart rate acquisition application for health promotion and wellness telehealth applications.

    Science.gov (United States)

    Gregoski, Mathew J; Mueller, Martina; Vertegel, Alexey; Shaporev, Aleksey; Jackson, Brenda B; Frenzel, Ronja M; Sprehn, Sara M; Treiber, Frank A

    2012-01-01

    Objective. Current generation smartphones' video camera technologies enable photoplethysmographic (PPG) acquisition and heart rate (HR) measurement. The study objective was to develop an Android application and compare HRs derived from a Motorola Droid to electrocardiograph (ECG) and Nonin 9560BT pulse oximeter readings during various movement-free tasks. Materials and Methods. HRs were collected simultaneously from 14 subjects, ages 20 to 58, healthy or with clinical conditions, using the 3 devices during 5-minute periods while at rest, reading aloud under observation, and playing a video game. Correlation between the 3 devices was determined, and Bland-Altman plots for all possible pairs of devices across all conditions assessed agreement. Results. Across conditions, all device pairs showed high correlations. Bland-Altman plots further revealed the Droid as a valid measure for HR acquisition. Across all conditions, the Droid compared to ECG, 95% of the data points (differences between devices) fell within the limits of agreement. Conclusion. The Android application provides valid HRs at varying levels of movement free mental/perceptual motor exertion. Lack of electrode patches or wireless sensor telemetric straps make it advantageous for use in mobile-cell-phone-delivered health promotion and wellness programs. Further validation is needed to determine its applicability while engaging in physical movement-related activities.

  10. Development and Validation of a Smartphone Heart Rate Acquisition Application for Health Promotion and Wellness Telehealth Applications

    Directory of Open Access Journals (Sweden)

    Mathew J. Gregoski

    2012-01-01

    Full Text Available Objective. Current generation smartphones' video camera technologies enable photoplethysmographic (PPG acquisition and heart rate (HR measurement. The study objective was to develop an Android application and compare HRs derived from a Motorola Droid to electrocardiograph (ECG and Nonin 9560BT pulse oximeter readings during various movement-free tasks. Materials and Methods. HRs were collected simultaneously from 14 subjects, ages 20 to 58, healthy or with clinical conditions, using the 3 devices during 5-minute periods while at rest, reading aloud under observation, and playing a video game. Correlation between the 3 devices was determined, and Bland-Altman plots for all possible pairs of devices across all conditions assessed agreement. Results. Across conditions, all device pairs showed high correlations. Bland-Altman plots further revealed the Droid as a valid measure for HR acquisition. Across all conditions, the Droid compared to ECG, 95% of the data points (differences between devices fell within the limits of agreement. Conclusion. The Android application provides valid HRs at varying levels of movement free mental/perceptual motor exertion. Lack of electrode patches or wireless sensor telemetric straps make it advantageous for use in mobile-cell-phone-delivered health promotion and wellness programs. Further validation is needed to determine its applicability while engaging in physical movement-related activities.

  11. The data acquisition system used in one-dimension multichannel fast electron energy loss spectrometer

    International Nuclear Information System (INIS)

    Jiang Weichun; Zhu Linfan; Zhang Yijun; Xu Kezuo

    2010-01-01

    It describes a data acquisition system used in one dimension multichannel fast electron energy loss spectrometer, which can work in scan acquisition mode and static acquisition mode. The timing precision of the scan mode is less than 4 μs by utilizing the gated signal generated by data acquisition card DAQ2010 and an AND logic circuit. A timer card PCI8554 is used to synchronize the data acquisition card and the personal computer. The scan voltage supply is controlled by the personal computer through the RS232 interface. The multithreading technology is used in the acquisition software in order to improve the accommodating-err ability of the acquisition system. A satisfactory test result is given. (authors)

  12. Post-Acquisition IT Integration

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Yetton, Philip

    2013-01-01

    The extant research on post-acquisition IT integration analyzes how acquirers realize IT-based value in individual acquisitions. However, serial acquirers make 60% of acquisitions. These acquisitions are not isolated events, but are components in growth-by-acquisition programs. To explain how...... serial acquirers realize IT-based value, we develop three propositions on the sequential effects on post-acquisition IT integration in acquisition programs. Their combined explanation is that serial acquirers must have a growth-by-acquisition strategy that includes the capability to improve...... IT integration capabilities, to sustain high alignment across acquisitions and to maintain a scalable IT infrastructure with a flat or decreasing cost structure. We begin the process of validating the three propositions by investigating a longitudinal case study of a growth-by-acquisition program....

  13. Foreign direct investment mode choice : entry and establishment modes in transition economies

    NARCIS (Netherlands)

    Dikova, Desislava; van Witteloostuijn, Arien

    In this study, we bridge two streams of foreign direct investment literature, specifically studies on establishment mode choice (i.e., the choice between an acquisition and a greenfield establishment) and studies on entry mode choice (i.e., the choice between a wholly owned outlet and a subsidiary

  14. Ella-V and technology usage technology usage in an english language and literacy acquisition validation randomized controlled trial study

    OpenAIRE

    Roisin P. Corcoran; Steven M. Ross; Beverly J. Irby; Fuhui Tong; Rafael Lara-Alecio; Cindy Guerrero

    2014-01-01

    This paper describes the use of technology to provide virtual professional development (VPD) for teachers and to conduct classroom observations in a study of English Language Learner (ELL) instruction in grades K–3. The technology applications were part of a cluster randomized control trial (RCT) design for a federally funded longitudinal validation study of a particular program, English Language and Literacy Acquisition-Validation, ELLA- V, to determine its degree of impact on English oral l...

  15. Consumption Skill Acquisition in Ski Schools

    DEFF Research Database (Denmark)

    Woermann, Niklas; Wieser, Verena

    2016-01-01

    Remedying the absence of a cultural theory of consumption skill acquisition, we use video data to explore how consumers learn in ski schools. We identify six modes of skill acquisition and theorize the interplay between the sensori-motor system, the conscious state of skillful coping...

  16. Expansion of the data acquisition system for the 20 MV tandem accelerator

    International Nuclear Information System (INIS)

    Tomita, Yoshiaki

    1981-02-01

    This report describes an expansion of the program of the data acquisition system for the 20 MV tandem accelerator. By the present expansion it became possible to change the accuisition mode or to use non-standard CAMAC modules with partial modification of the program according to well defined prescriptions. The modification can be made by writing microprograms for the MBD or appending subroutines for the reduced spectra in the LIST mode data acquisition. The new program can handle up to 32 ADC's in the standard LIST mode data acquisition. The present expansion aimed to increase the flexibility in data acquisition. It can also be applied to control experimental devices. (author)

  17. Data Acquisition System

    International Nuclear Information System (INIS)

    Cirstea, C.D.; Buda, S.I.; Constantin, F.

    2005-01-01

    This paper deals with a multi parametric acquisition system developed for a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  18. Data acquisition system

    International Nuclear Information System (INIS)

    Cirstea, D.C.; Buda, S.I.; Constantin, F.

    2005-01-01

    The topic of this paper deals with a multi parametric acquisition system developed around a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming, the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  19. Estudo comparativo da qualidade de imagem dos modos de aquisição da PET: validação de um protocolo para reduzir a dose de radiação Comparative study on imaging quality in PET acquisition modes: validation of a protocol for reducing the radiation dose

    Directory of Open Access Journals (Sweden)

    Solange Amorim Nogueira

    2009-04-01

    Full Text Available OBJETIVO: O presente experimento visa a validar um protocolo de aquisição em 3D na tomografia por emissão de pósitrons, em substituição ao modo 2D, de forma a reduzir a dose de radiação nos pacientes, sem perda da qualidade de imagens. MATERIAIS E MÉTODOS: Foram realizadas 27 simulações em equipamento Discovery ST, nos modos 2D com quatro minutos de aquisição e 3D com dois e quatro minutos. Utilizou-se um simulador do protocolo da National Electrical Manufacturers Association. No interior deste simulador estão inseridas seis esferas com diferentes diâmetros para a determinação da qualidade de imagem. As aquisições foram comparadas por três médicos nucleares, sem que eles identificassem o modo de aquisição. Cada observador atribuiu o valor igual a 1 quando alguma esfera não foi identificada ou valor 2 para esferas visíveis. RESULTADOS: A análise qualitativa pelo kappa generalizado demonstrou que a frequência de esferas visíveis foi maior no modo 3D com quatro minutos (85% e a porcentagem de concordância também foi maior (88,9%, com kappa generalizado = 0,725 [0,507;0,942]. CONCLUSÃO: O modo 3D com quatro minutos de aquisição e com menores atividades de FDG-18F pode ser utilizado em pacientes com biótipo equivalente ao simulador, sem perda de qualidade de imagem.OBJECTIVE: The present study is aimed at validating a 3D acquisition protocol for positron emission tomography as a replacement for the 2D mode, to reduce the radiation dose delivered to patients, without any loss in the quality of images. MATERIALS AND METHODS: The study comprised 27 simulations in a Discovery ST equipment with four-minute 2D acquisitions, and two-minute and four-minute 3D acquisitions, utilizing a chest phantom according to the National Electrical Manufacturers Association protocol. Six spheres with different diameters were inserted into this phantom as a means for determining the images quality. The images were blindly reviewed by three

  20. Dual Rotating Rake Measurements of Higher-Order Duct Modes: Validation Using Experimental and Numerical Data

    Science.gov (United States)

    Dahl, Milo D.; Hixon, Duane R.; Sutliff, Daniel L.

    2018-01-01

    A rotating rake mode measurement system was designed to measure acoustic duct modes generated by a fan stage. After analysis of the measured data, the mode coefficient amplitudes and phases were quantified. Early studies using this system found that mode power levels computed from rotating rake measured data would agree with the far-field power levels. However, this agreement required that the sound from the noise sources within the duct propagated outward from the duct exit without reflection and previous studies suggested conditions could exist where significant reflections could occur. This paper shows that mounting a second rake to the rotating system, with an offset in both the axial and the azimuthal directions, measures the data necessary to determine the modes propagating in both directions within a duct. The rotating rake data analysis technique was extended to include the data measured by the second rake. The analysis resulted in a set of circumferential mode coefficients at each of the two rake microphone locations. Radial basis functions were then least-squares fit to this data to obtain the radial mode coefficients for the modes propagating in both directions within the duct while accounting for the presence of evanescent modes. The validation of the dual-rotating-rake measurements was conducted using data from a combination of experiments and numerical calculations to compute reflection coefficients and other mode coefficient ratios. Compared to results from analytical and numerical computations, the results from dual-rotating-rake measured data followed the expected trends when frequency, mode number, and duct termination geometry were changed.

  1. Acquisitions and Real Options : The Greenfield Alternative

    NARCIS (Netherlands)

    Brouthers, Keith D.; Dikova, Desislava

    P>Although acquisitions are a popular way to enter new markets, empirical evidence tends to indicate few benefits accrue to acquiring firms. This might be the case because firms use acquisitions when they should be employing an alternative mode of expansion. Applying real options theory to this

  2. The Assessment of Selectivity in Different Quadrupole-Orbitrap Mass Spectrometry Acquisition Modes

    Science.gov (United States)

    Berendsen, Bjorn J. A.; Wegh, Robin S.; Meijer, Thijs; Nielen, Michel W. F.

    2015-02-01

    Selectivity of the confirmation of identity in liquid chromatography (tandem) mass spectrometry using Q-Orbitrap instrumentation was assessed using different acquisition modes based on a representative experimental data set constructed from 108 samples, including six different matrix extracts and containing over 100 analytes each. Single stage full scan, all ion fragmentation, and product ion scanning were applied. By generating reconstructed ion chromatograms using unit mass window in targeted MS2, selected reaction monitoring (SRM), regularly applied using triple-quadrupole instruments, was mimicked. This facilitated the comparison of single stage full scan, all ion fragmentation, (mimicked) SRM, and product ion scanning applying a mass window down to 1 ppm. Single factor Analysis of Variance was carried out on the variance (s2) of the mass error to determine which factors and interactions are significant parameters with respect to selectivity. We conclude that selectivity is related to the target compound (mainly the mass defect), the matrix, sample clean-up, concentration, and mass resolution. Selectivity of the different instrumental configurations was quantified by counting the number of interfering peaks observed in the chromatograms. We conclude that precursor ion selection significantly contributes to selectivity: monitoring of a single product ion at high mass accuracy with a 1 Da precursor ion window proved to be equally selective or better to monitoring two transition products in mimicked SRM. In contrast, monitoring a single fragment in all ion fragmentation mode results in significantly lower selectivity versus mimicked SRM. After a thorough inter-laboratory evaluation study, the results of this study can be used for a critical reassessment of the current identification points system and contribute to the next generation of evidence-based and robust performance criteria in residue analysis and sports doping.

  3. The prototype triggerless data acquisition of the PANDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Milan; Reiter, Simon; Lange, Soeren; Kuehn, Wolfgang [II. Physikalisches Institut, Giessen Univ. (Germany); Collaboration: PANDA-Collaboration

    2016-07-01

    The PANDA detector will operate with a very high interaction rate of up to 20 MHz, in a free streaming mode without hardware trigger. Data filtering will be performed by complete online event reconstruction with a highly parallelized farm of FPGAs as first level and on a farm of GPUs or PCs as a second level. The requirement is a background reduction by a factor of >1000. A prototype trigger-less data acquisition (PTDAQ) system for the detector validation measurements comprises free streaming and synchronization readout, for event building and filtering has been developed. A first in beam environment test was performed at the Mainzer Mikrotron, reading out the barrel electromagnetic calorimeter prototype (Proto120).

  4. Dosimetric comparison of water phantoms, ion chambers, and data acquisition modes for LINAC characterization

    International Nuclear Information System (INIS)

    Cruz, Wilbert; Narayanasamy, Ganesh; Papanikolaou, Niko; Stathakis, Sotirios

    2015-01-01

    set up may be causing the slight deviation in data. It is important to identify the exact source of the potential errors to ensure that proper tank usage is performed when making such measurements to ensure that patient safety is in compliance. Beam profiles done with different chambers and tanks showed little to no deviation from one to another. With regards to continuous versus discrete data measurements the main difference was in the data processing technique used. Discrete data obtained required less data processing as compared to the continuous data acquired. - Highlights: • Dosimetric comparison between continuous and discrete data acquisition was performed. • Two water phantoms (PTW MP3-M and IBA Blue phantom) and multiple ion chambers were compared for dosimetric accuracy. • Discrete data acquisition required less data processing as compared to continuous data acquisition mode. • PDDs and profile scans with different tanks and chambers showed little to no difference.

  5. Validation of new 3D post processing algorithm for improved maximum intensity projections of MR angiography acquisitions in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Bosmans, H; Verbeeck, R; Vandermeulen, D; Suetens, P; Wilms, G; Maaly, M; Marchal, G; Baert, A L [Louvain Univ. (Belgium)

    1995-12-01

    The objective of this study was to validate a new post processing algorithm for improved maximum intensity projections (mip) of intracranial MR angiography acquisitions. The core of the post processing procedure is a new brain segmentation algorithm. Two seed areas, background and brain, are automatically detected. A 3D region grower then grows both regions towards each other and this preferentially towards white regions. In this way, the skin gets included into the final `background region` whereas cortical blood vessels and all brain tissues are included in the `brain region`. The latter region is then used for mip. The algorithm runs less than 30 minutes on a full dataset on a Unix workstation. Images from different acquisition strategies including multiple overlapping thin slab acquisition, magnetization transfer (MT) MRA, Gd-DTPA enhanced MRA, normal and high resolution acquisitions and acquisitions from mid field and high field systems were filtered. A series of contrast enhanced MRA acquisitions obtained with identical parameters was filtered to study the robustness of the filter parameters. In all cases, only a minimal manual interaction was necessary to segment the brain. The quality of the mip was significantly improved, especially in post Gd-DTPA acquisitions or using MT, due to the absence of high intensity signals of skin, sinuses and eyes that otherwise superimpose on the angiograms. It is concluded that the filter is a robust technique to improve the quality of MR angiograms.

  6. Validation of new 3D post processing algorithm for improved maximum intensity projections of MR angiography acquisitions in the brain

    International Nuclear Information System (INIS)

    Bosmans, H.; Verbeeck, R.; Vandermeulen, D.; Suetens, P.; Wilms, G.; Maaly, M.; Marchal, G.; Baert, A.L.

    1995-01-01

    The objective of this study was to validate a new post processing algorithm for improved maximum intensity projections (mip) of intracranial MR angiography acquisitions. The core of the post processing procedure is a new brain segmentation algorithm. Two seed areas, background and brain, are automatically detected. A 3D region grower then grows both regions towards each other and this preferentially towards white regions. In this way, the skin gets included into the final 'background region' whereas cortical blood vessels and all brain tissues are included in the 'brain region'. The latter region is then used for mip. The algorithm runs less than 30 minutes on a full dataset on a Unix workstation. Images from different acquisition strategies including multiple overlapping thin slab acquisition, magnetization transfer (MT) MRA, Gd-DTPA enhanced MRA, normal and high resolution acquisitions and acquisitions from mid field and high field systems were filtered. A series of contrast enhanced MRA acquisitions obtained with identical parameters was filtered to study the robustness of the filter parameters. In all cases, only a minimal manual interaction was necessary to segment the brain. The quality of the mip was significantly improved, especially in post Gd-DTPA acquisitions or using MT, due to the absence of high intensity signals of skin, sinuses and eyes that otherwise superimpose on the angiograms. It is concluded that the filter is a robust technique to improve the quality of MR angiograms

  7. Hardware and software for image acquisition in nuclear medicine

    International Nuclear Information System (INIS)

    Fideles, E.L.; Vilar, G.; Silva, H.S.

    1992-01-01

    A system for image acquisition and processing in nuclear medicine is presented, including the hardware and software referring to acquisition. The hardware is consisted of an analog-digital conversion card, developed in wire-wape. Its function is digitate the analogic signs provided by gamma camera. The acquisitions are made in list or frame mode. (C.G.C.)

  8. Variability of textural features in FDG PET images due to different acquisition modes and reconstruction parameters

    DEFF Research Database (Denmark)

    Galavis, P.E.; Hollensen, Christian; Jallow, N.

    2010-01-01

    Background. Characterization of textural features (spatial distributions of image intensity levels) has been considered as a tool for automatic tumor segmentation. The purpose of this work is to study the variability of the textural features in PET images due to different acquisition modes...... reconstruction parameters. Lesions were segmented on a default image using the threshold of 40% of maximum SUV. Fifty different texture features were calculated inside the tumors. The range of variations of the features were calculated with respect to the average value. Results. Fifty textural features were...... classified based on the range of variation in three categories: small, intermediate and large variability. Features with small variability (range 30%). Conclusion. Textural features such as entropy-first order, energy, maximal correlation coefficient, and low-gray level run emphasis exhibited small...

  9. Validation of an Integrated Airframe and Turbofan Engine Simulation for Evaluation of Propulsion Control Modes

    Science.gov (United States)

    Litt, Jonathan S.; Sowers, T Shane; Liu, Yuan; Owen, A. Karl; Guo, Ten-Huei

    2015-01-01

    The National Aeronautics and Space Administration (NASA) has developed independent airframe and engine models that have been integrated into a single real-time aircraft simulation for piloted evaluation of propulsion control algorithms. In order to have confidence in the results of these evaluations, the integrated simulation must be validated to demonstrate that its behavior is realistic and that it meets the appropriate Federal Aviation Administration (FAA) certification requirements for aircraft. The paper describes the test procedures and results, demonstrating that the integrated simulation generally meets the FAA requirements and is thus a valid testbed for evaluation of propulsion control modes.

  10. 48 CFR 47.305-14 - Mode of transportation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Mode of transportation. 47... CONTRACT MANAGEMENT TRANSPORTATION Transportation in Supply Contracts 47.305-14 Mode of transportation. Generally, solicitations shall not specify a particular mode of transportation or a particular carrier. If...

  11. OPAL: selection and acquisition of LEP data

    International Nuclear Information System (INIS)

    Le Du, P.

    1985-01-01

    The OPAL project (Omni Purpose aparatus for LEP) is presented. It will be a frame and an example to explain the main problems and limitations concerning the mode of event selection, acquisition and information transfer to the final registering system. A quick review of the different problems related to data selection and acquisition is made [fr

  12. Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT

    International Nuclear Information System (INIS)

    Johnston, Jennifer H.; Podberesky, Daniel J.; Larson, David B.; Alsip, Christopher; Yoshizumi, Terry T.; Angel, Erin; Barelli, Alessandra; Toncheva, Greta; Egelhoff, John C.; Anderson-Evans, Colin; Nguyen, Giao B.; Frush, Donald P.; Salisbury, Shelia R.

    2013-01-01

    Advanced multidetector CT systems facilitate volumetric image acquisition, which offers theoretic dose savings over helical acquisition with shorter scan times. Compare effective dose (ED), scan duration and image noise using 320- and 64-detector CT scanners in various acquisition modes for clinical chest, abdomen and pelvis protocols. ED and scan durations were determined for 64-detector helical, 160-detector helical and volume modes under chest, abdomen and pelvis protocols on 320-detector CT with adaptive collimation and 64-detector helical mode on 64-detector CT without adaptive collimation in a phantom representing a 5-year-old child. Noise was measured as standard deviation of Hounsfield units. Compared to 64-detector helical CT, all acquisition modes on 320-detector CT resulted in lower ED and scan durations. Dose savings were greater for chest (27-46%) than abdomen/pelvis (18-28%) and chest/abdomen/pelvis imaging (8-14%). Noise was similar across scanning modes, although some protocols on 320-detector CT produced slightly higher noise. Dose savings can be achieved for chest, abdomen/pelvis and chest/abdomen/pelvis examinations on 320-detector CT compared to helical acquisition on 64-detector CT, with shorter scan durations. Although noise differences between some modes reached statistical significance, this is of doubtful diagnostic significance and will be studied further in a clinical setting. (orig.)

  13. Validation of CryoSat-2 SARIn Performance over Arctic Sea Ice

    Science.gov (United States)

    Di Bella, A.; Skourup, H.; Bouffard, J.; Parrinello, T.

    2016-08-01

    The main objective of this work is to validate CryoSat-2 (CS2) SARIn performance over sea ice by use of airborne laser altimetry data obtained during the CryoVEx 2012 campaign. A study by [1] has shown that the extra information from the CS2 SARIn mode increases the number of valid sea surface height estimates which are usually discarded in the SAR mode due to snagging of the radar signal. As the number of valid detected leads increases, the uncertainty of the freeboard heights decreases.In this study, the snow freeboard heights estimated using data from the airborne laser scanner are used to validate the sea ice freeboard obtained by processing CS2 SARIn level 1b waveforms. The possible reduction in the random freeboard uncertainty is investigated comparing two scenarios, i.e. a SAR-like and a SARIn acquisition.It is observed that using the extra phase information, CS2 is able to detect leads up to 2370 m off-nadir. A reduction in the the total random freeboard uncertainty of ˜40% is observed by taking advantage of the CS2 interferometric capabilities, which enable to include ˜35% of the wave-forms discarded in the SAR-like scenario.

  14. Compliance with therapy in patients with chronic hepatitis C: associations with psychiatric symptoms, interpersonal problems, and mode of acquisition.

    Science.gov (United States)

    Kraus, M R; Schäfer, A; Csef, H; Faller, H; Mörk, H; Scheurlen, M

    2001-10-01

    Tolerance of interferon-a therapy for hepatitis C is often poor and medication is expensive. Compliance with diagnostic procedures and, even more important, with medical treatment is obviously critical to minimize the rate of dropouts and to maximize cost efficiency. Moreover, a good concordance with scheduled follow-ups is important for early recognition and treatment of interferon-associated side effects. Therefore, we investigated psychiatric symptoms, interpersonal problems, different modes of acquisition, and sociodemographic factors in HCV-infected patients as possible predictor variables of good versus poor compliance. In a longitudinal study, 74 patients with chronic hepatitis C (CHC) who fulfilled the criteria for treatment with interferon (IFN)-alpha-2b with or without ribavirin were investigated prospectively to identify those at risk for poor compliance during IFN medication. To assess predictive factors, we used both IIP-C (Inventory of Interpersonal Problems) and SCL-90-R (Symptom Check List 90 Items Revised) as psychometric instruments. Sociodemographic and somatic variables as well as compliance during IFN therapy were also evaluated. Poor compliance before or during medication was demonstrated by 23% (N = 17) of HCV patients. Sociodemographic factors and mode of acquisition, particularly former intravenous drug (IVD) abuse were not significantly linked with compliance. Logistic regression analysis demonstrated that the subgroup of patients with compliance problems was best identified by both pretherapeutic psychiatric symptoms and interpersonal problems. Predictive value was best and significant for anger-hostility (P = 0.009), intrusive (P = 0.014), depression (P = 0.015), and phobic anxiety (P = 0.049). Adopting this statistical prediction model, sensitivity was 47.1%, but specificity reached 98.3%. In total, 86.5% of cases were classified correctly. In situations of unclear indication for IFN therapy, psychological variables assessment of before

  15. Dynamic mode decomposition for plasma diagnostics and validation

    Science.gov (United States)

    Taylor, Roy; Kutz, J. Nathan; Morgan, Kyle; Nelson, Brian A.

    2018-05-01

    We demonstrate the application of the Dynamic Mode Decomposition (DMD) for the diagnostic analysis of the nonlinear dynamics of a magnetized plasma in resistive magnetohydrodynamics. The DMD method is an ideal spatio-temporal matrix decomposition that correlates spatial features of computational or experimental data while simultaneously associating the spatial activity with periodic temporal behavior. DMD can produce low-rank, reduced order surrogate models that can be used to reconstruct the state of the system with high fidelity. This allows for a reduction in the computational cost and, at the same time, accurate approximations of the problem, even if the data are sparsely sampled. We demonstrate the use of the method on both numerical and experimental data, showing that it is a successful mathematical architecture for characterizing the helicity injected torus with steady inductive (HIT-SI) magnetohydrodynamics. Importantly, the DMD produces interpretable, dominant mode structures, including a stationary mode consistent with our understanding of a HIT-SI spheromak accompanied by a pair of injector-driven modes. In combination, the 3-mode DMD model produces excellent dynamic reconstructions across the domain of analyzed data.

  16. Reflector automatic acquisition and pointing based on auto-collimation theodolite

    Science.gov (United States)

    Luo, Jun; Wang, Zhiqian; Wen, Zhuoman; Li, Mingzhu; Liu, Shaojin; Shen, Chengwu

    2018-01-01

    An auto-collimation theodolite (ACT) for reflector automatic acquisition and pointing is designed based on the principle of autocollimators and theodolites. First, the principle of auto-collimation and theodolites is reviewed, and then the coaxial ACT structure is developed. Subsequently, the acquisition and pointing strategies for reflector measurements are presented, which first quickly acquires the target over a wide range and then points the laser spot to the charge coupled device zero position. Finally, experiments are conducted to verify the acquisition and pointing performance, including the calibration of the ACT, the comparison of the acquisition mode and pointing mode, and the accuracy measurement in horizontal and vertical directions. In both directions, a measurement accuracy of ±3″ is achieved. The presented ACT is suitable for automatic pointing and monitoring the reflector over a small scanning area and can be used in a wide range of applications such as bridge structure monitoring and cooperative target aiming.

  17. Experimental validation of an analytical kinetic model for edge-localized modes in JET-ITER-like wall

    Science.gov (United States)

    Guillemaut, C.; Metzger, C.; Moulton, D.; Heinola, K.; O’Mullane, M.; Balboa, I.; Boom, J.; Matthews, G. F.; Silburn, S.; Solano, E. R.; contributors, JET

    2018-06-01

    The design and operation of future fusion devices relying on H-mode plasmas requires reliable modelling of edge-localized modes (ELMs) for precise prediction of divertor target conditions. An extensive experimental validation of simple analytical predictions of the time evolution of target plasma loads during ELMs has been carried out here in more than 70 JET-ITER-like wall H-mode experiments with a wide range of conditions. Comparisons of these analytical predictions with diagnostic measurements of target ion flux density, power density, impact energy and electron temperature during ELMs are presented in this paper and show excellent agreement. The analytical predictions tested here are made with the ‘free-streaming’ kinetic model (FSM) which describes ELMs as a quasi-neutral plasma bunch expanding along the magnetic field lines into the Scrape-Off Layer without collisions. Consequences of the FSM on energy reflection and deposition on divertor targets during ELMs are also discussed.

  18. Exploitative and Deceptive Resource Acquisition Strategies

    Directory of Open Access Journals (Sweden)

    Joshua J. Reynolds

    2015-07-01

    Full Text Available Life history strategy (LHS and life history contingencies (LHCs should theoretically influence the use of exploitative and deceptive resource acquisition strategies. However, little research has been done in this area. The purpose of the present work was to create measures of exploitative strategies and test the predictions of life history theory. Pilot studies developed and validated a behavioral measure of cheating called the Dot Game. The role of individual LHS and LHCs (manipulated via validated story primes on cheating was investigated in Study 1. Studies 2a through 2c were conducted to develop and validate a self-report measure called the Exploitative and Deceptive Resource Acquisition Strategy Scale (EDRASS. Finally, Study 3 investigated life history and EDRASS. Results indicated that while LHS influences exploitative strategies, life history contingences had little effect. Implications of these findings are discussed.

  19. A 200-Channel Area-Power-Efficient Chemical and Electrical Dual-Mode Acquisition IC for the Study of Neurodegenerative Diseases.

    Science.gov (United States)

    Guo, Jing; Ng, Waichiu; Yuan, Jie; Li, Suwen; Chan, Mansun

    2016-06-01

    Microelectrode array (MEA) can be used in the study of neurodegenerative diseases by monitoring the chemical neurotransmitter release and the electrical potential simultaneously at the cellular level. Currently, the MEA technology is migrating to more electrodes and higher electrode density, which raises power and area constraints on the design of acquisition IC. In this paper, we report the design of a 200-channel dual-mode acquisition IC with highly efficient usage of power and area. Under the constraints of target noise and fast settling, the current channel design saves power by including a novel current buffer biased in discrete time (DT) before the TIA (transimpedance amplifier). The 200 channels are sampled at 20 kS/s and quantized by column-wise SAR ADCs. The prototype IC was fabricated in a 0.18 μm CMOS process. Silicon measurements show the current channel has 21.6 pArms noise with cyclic voltammetry (CV) and 0.48 pArms noise with constant amperometry (CA) while consuming 12.1 μW . The voltage channel has 4.07 μVrms noise in the bandwidth of 100 kHz and 0.2% nonlinearity while consuming 9.1 μW. Each channel occupies 0.03 mm(2) area, which is among the smallest.

  20. Minimal formulation of the linear spatial analysis of capillary jets: Validity of the two-mode approach

    Science.gov (United States)

    González, H.; Vazquez, P. A.; García, F. J.; Guerrero, J.

    2018-04-01

    A rigorous and complete formulation of the linear evolution of harmonically stimulated capillary jets should include infinitely many spatial modes to account for arbitrary exit conditions [J. Guerrero et al., J. Fluid Mech. 702, 354 (2012), 10.1017/jfm.2012.182]. However, it is not rare to find works in which only the downstream capillary dominant mode, the sole unstable one, is retained, with amplitude determined by the jet deformation at the exit. This procedure constitutes an oversimplification, unable to handle a flow rate perturbation without jet deformation at the exit (the most usual conditions). In spite of its decaying behavior, the other capillary mode (subdominant) must be included in what can be called a "minimal linear formulation." Deformation and mean axial velocity amplitudes at the jet exit are the two relevant parameters to simultaneously find the amplitudes of both capillary modes. Only once these amplitudes are found, the calculation of the breakup length may be eventually simplified by disregarding the subdominant mode. Simple recipes are provided for predicting the breakup length, which are checked against our own numerical simulations. The agreement is better than in previous attempts in the literature. Besides, the limits of validity of the linear formulation are explored in terms of the exit velocity amplitude, the wave number, the Weber number, and the Ohnesorge number. Including the subdominant mode extends the range of amplitudes for which the linear model gives accurate predictions, the criterion for keeping this mode being that the breakup time must be shorter than a given formula. It has been generally assumed that the shortest intact length happens for the stimulation frequency with the highest growth rate. However, we show that this correlation is not strict because the amplitude of the dominant mode has a role in the breakup process and it depends on the stimulation frequency.

  1. The Bochum on-line data acquisition system

    International Nuclear Information System (INIS)

    Paul, H.J.; Freiesleben, H.

    1986-01-01

    We describe an on-line data acquisition system based on a PDP 11 computer with CAMAC hardware. The software fully exploits the real-time features of the RSX-11M operating system. The basic characteristics of the program package, mainly written in FORTRAN 77, are: multitasking, shared common blocks, dynamical access to CAMAC hardware and data, and command orientated user interface. The system is particularly tailored for data acquisition in list mode of up to 64 parameters. (orig.)

  2. Greenfields and acquisitions: a comparative analysis

    Directory of Open Access Journals (Sweden)

    Nicolae MARINESCU

    2016-07-01

    Full Text Available This paper compares greenfields and acquisitions as foreign direct investment (FDI alternatives used by transnational corporations (TNCs. First, the determinants leading to the choice of companies between the two modes of entry into a foreign market are laid out. Then, specific features of each alternative are highlighted, by contrasting the advantages and disadvantages of both types of FDI. Based on this analysis, some conclusions are drawn in the end concerning the most important factors that influence the decision of a company whether to choose a greenfield investment or an acquisition.

  3. Pseudo LRM waveforms from CryoSat SARin acquisition

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Bouffard, Jerome; Parrinello, Tommaso; Féménias, Pierre

    2016-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. The main payload of CryoSat is a Ku-band pulsewidth limited radar altimeter, called SIRAL (Synthetic interferometric radar altimeter). When commanded in SARIn (synthetic aperture radar interferometry) mode, through coherent along-track processing of the returns received from two antennas, the interferometric phase related to the first arrival of the echo is used to retrieve the angle of arrival of the scattering in the across-track direction. When SIRAL operates in SAR or SARin mode, the obtained waveforms have an along-track resolution and a speckle reduction which is increased with respect to the pulse-limited waveforms. Anyway, in order to analyze the continuity of the geophysical retrieved parameters among different acquisition modes, techniques to transform SARin mode data to pseudo-LRM mode data are welcome. The transformation process is known as SAR reduction and it is worth recalling here that only approximate pseudo-LRM waveforms can be obtained in case of closed burst acquisitions, as SIRAL operates. A SAR reduction processing scheme has been developed to obtain pseudo-LRM waveforms from CryoSat SARin acquisition. As a trade-off between the along-track length on Earth surface contributing to one SARin pseudo-LRM waveform and the noisiness of the waveform itself, it has been chosen a SAR reduction approach based on the averaging of all the SARin echoes received each 20Hz, resulting in one pseudo-LRM waveform for each SARin burst given the SARin burst repetition period. SARin pseudo-LRM waveforms have been produced for CryoSat acquisition both on ice and sea surfaces, aiming at verifying the continuity of the retracked surface height over the ellipsoid between genuine LRM products and pseudo-LRM products. Moreover, the retracked height from the SARin pseudo-LRM has been

  4. The purpose and coherence of the rules on good faith acquisition and acquisitive prescription in the European Draft Common Frame of Reference: A tale of two gatekeepers

    NARCIS (Netherlands)

    Salomons, A.

    2015-01-01

    The drafters of Book VIII DCFR have consistently tried to formulate rules on the related topics of acquisitive prescription and good faith acquisition to further the underlying policy goals: where ordinary transfer has failed, good faith acquisition should instantly validate transfers a non domino

  5. Calibration And Validation Of CryoSat-2 Low Resolution Mode Data

    Science.gov (United States)

    Naeije, M.; Schrama, E.; Scharroo, R.

    2011-02-01

    Running ahead of the continuously growing need for operational use of sea level products, TUDelft started off the Radar Altimeter Database System RADS many years ago. This system attends to a global international sea- level service. It supports, on one hand, science, like studies on ocean circulation, El Nio, sea level change, and ice topography, and on the other hand (offshore) operations, like delivery of ocean current information, wind and wave statistics, ice detection and ice classification. At present, the database is used by a large scientific community throughout the world, and is daily maintained and developed by Altimetrics LLC, TUDelft and NOAA. It contains all historic altimeter data, and now has to be up- dated with the data from ESAs ice mission CryoSat-2, which was launched successfully in April 2010. These new data are important to augment the data set and by that to improve the estimates of sea level change and its contributors. For this the data have to be validated and calibrated, necessary corrections added and improved (including modelling of corrections that are not directly available from the CryoSat-2 platform), and the orbit ac- curacy verified and if possible the orbits brushed up. Subsequently, value-added ocean and ice products need to be developed in synergy with all the other satellite altimeter data. During the commissioning phase we primarily looked at the sanity of the available level-1b and level-2 Low Resolution Mode (LRM) data. Here, for the 2011 CryoSat Validation Workshop, we present the results of our calibration and validation of LRM L2 data by internal comparison of CryoSat-2 and external comparison with other satellites. We have established a range bias of 3.77 (measurement range too long) and a timing bias of 8.2ms (measurement range too late).

  6. Some Aspects of Developing Background Knowledge in Second Language Acquisition Revisited

    Science.gov (United States)

    Zashchitina, Galina; Moysyak, Natalia

    2017-01-01

    The article focuses on defining how background knowledge impacts on second-language acquisition by giving a brief overview of schema theory, the interaction of the basic modes of information processing. A challenge of dealing with culturally specific texts in second language acquisition is also touched upon. Different research-supported views on…

  7. A comprehensive, holistic people integration process for mergers and acquisitions

    Directory of Open Access Journals (Sweden)

    Rina P. Steynberg

    2011-03-01

    Research purpose: To develop and validate a comprehensive, holistic model for the people integration process during mergers and acquisitions. Motivation for the study: The literature on a comprehensive, holistic people integration process for mergers and acquisitions is sparse and fragmented. Research design, approach and method: A qualitative approach was adopted consisting of a three step process which solicited the views of seasoned M&A Practioners; these views were compared against the available literature. Finally, practioners were asked to critique the final model from a practice perspective. The utility of the final model was assessed against two mergers and acquisitions case studies. Main findings: A comprehensive, holistic people integration process model for mergers and acquisitions was developed and validated. However, this model will only significantly enhance mergers and acquisitions value realisation if it is applied from the appropriate vantage point. Practical/managerial implications: The proposed approach will increase the probability of a successful M&A people-wise and M&A value realisation. Contribution/value add: Theoretically, the development and validation of a M&A people process integration model; practically, guidelines for successful people integration; organisationally, significantly enhancing the chances of M&A success; and community wise, the reduction of the negative effects of M&A failure on communities.

  8. A new maximum power point method based on a sliding mode approach for solar energy harvesting

    International Nuclear Information System (INIS)

    Farhat, Maissa; Barambones, Oscar; Sbita, Lassaad

    2017-01-01

    Highlights: • Create a simple, easy of implement and accurate V_M_P_P estimator. • Stability analysis of the proposed system based on the Lyapunov’s theory. • A comparative study versus P&O, highlight SMC good performances. • Construct a new PS-SMC algorithm to include the partial shadow case. • Experimental validation of the SMC MPP tracker. - Abstract: This paper presents a photovoltaic (PV) system with a maximum power point tracking (MPPT) facility. The goal of this work is to maximize power extraction from the photovoltaic generator (PVG). This goal is achieved using a sliding mode controller (SMC) that drives a boost converter connected between the PVG and the load. The system is modeled and tested under MATLAB/SIMULINK environment. In simulation, the sliding mode controller offers fast and accurate convergence to the maximum power operating point that outperforms the well-known perturbation and observation method (P&O). The sliding mode controller performance is evaluated during steady-state, against load varying and panel partial shadow (PS) disturbances. To confirm the above conclusion, a practical implementation of the maximum power point tracker based sliding mode controller on a hardware setup is performed on a dSPACE real time digital control platform. The data acquisition and the control system are conducted all around dSPACE 1104 controller board and its RTI environment. The experimental results demonstrate the validity of the proposed control scheme over a stand-alone real photovoltaic system.

  9. A single-mode data acquisition architecture for PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Sportelli, Giancarlo; Belcari, Nicola; Bisogni, Maria Giuseppina; Camarlinghi, Niccolo; Zaccaro, Emanuele; Del Guerra, Alberto [Department of Physics, University of Pisa and INFN, Pisa (Italy)

    2015-05-18

    The development of MRI compatible detectors based on compact solid state photomultipliers has recently led to simultaneous fully integrated PET/MRI systems for human imaging. The PET acquisition design for MRI integration is known to have several additional constraints, including smaller space, electromagnetic compatibility issues and thermal management. The current work presents the PET acquisition architecture that has been developed for the TRIMAGE project, whose aim is to provide a cost effective, commercial grade trimodality PET/MRI/EEG scanner. The TRIMAGE PET component consists of 216 modules of 2.5 cm x 2.5 cm, arranged in 18 rectangular detectors of 5 cm x 15 cm, the latter in the axial direction, to form a full ring of 31 cm diameter. Each module consists of a staggered dual layer LYSO matrix read out by two arrays of 4 x 8 SiPMs and an ASIC. The detector board hosts a low-power low-end FPGA that performs pixel identification, energy calibration and handles the communication between the ASICs and the motherboard, which is located in proximity of the scanner. Data is streamed using high-density shielded cables and high-speed LVDS transmission to 9 low-end SoC FPGAs and from there to a central mainboard where coincidences and events statistics are processed. Coincidence data is finally transmitted to a host PC for image reconstruction. The proposed architecture and technological solutions will be presented and discussed.

  10. A single-mode data acquisition architecture for PET/MRI

    International Nuclear Information System (INIS)

    Sportelli, Giancarlo; Belcari, Nicola; Bisogni, Maria Giuseppina; Camarlinghi, Niccolo; Zaccaro, Emanuele; Del Guerra, Alberto

    2015-01-01

    The development of MRI compatible detectors based on compact solid state photomultipliers has recently led to simultaneous fully integrated PET/MRI systems for human imaging. The PET acquisition design for MRI integration is known to have several additional constraints, including smaller space, electromagnetic compatibility issues and thermal management. The current work presents the PET acquisition architecture that has been developed for the TRIMAGE project, whose aim is to provide a cost effective, commercial grade trimodality PET/MRI/EEG scanner. The TRIMAGE PET component consists of 216 modules of 2.5 cm x 2.5 cm, arranged in 18 rectangular detectors of 5 cm x 15 cm, the latter in the axial direction, to form a full ring of 31 cm diameter. Each module consists of a staggered dual layer LYSO matrix read out by two arrays of 4 x 8 SiPMs and an ASIC. The detector board hosts a low-power low-end FPGA that performs pixel identification, energy calibration and handles the communication between the ASICs and the motherboard, which is located in proximity of the scanner. Data is streamed using high-density shielded cables and high-speed LVDS transmission to 9 low-end SoC FPGAs and from there to a central mainboard where coincidences and events statistics are processed. Coincidence data is finally transmitted to a host PC for image reconstruction. The proposed architecture and technological solutions will be presented and discussed.

  11. Validation of the schema mode concept in personality disordered offenders

    NARCIS (Netherlands)

    Keulen-de Vos, Marije; Bernstein, David P.; Clark, Lee Anna; de Vogel, Vivienne; Bogaerts, S.; Slaats, Mariette; Arntz, Arnoud

    2017-01-01

    Purpose A core element of Schema Therapy (ST) is schema modes' or fluctuating emotional states. ST assumes that particular personality pathology consists of specific combinations of maladaptive schema modes. There is confirmatory evidence for the modes hypothesized to be central to borderline and

  12. A review of spelling acquisition

    DEFF Research Database (Denmark)

    Dich, Nadya; Cohn, Abigail C.

    2013-01-01

    This review article discusses how empirical data on the acquisition of spelling by children inform the question of the psycholinguistic validity of the phoneme, a concept central (at least implicitly) to most phonological theories. The paper reviews data on children's early spelling attempts...... literacy factors into modeling phonological knowledge. In this article, we show that the spelling acquisition data support and are best accounted for by models allowing for a hierarchy of representations, that learning to read and write has a profound effect on the phonological knowledge of an adult...

  13. Intelligent Assistants for Distributed Knowledge Acquisition, Integration, Validation, and Maintenance

    National Research Council Canada - National Science Library

    Tecuci, Gheorghe; Boicu, Mihai

    2008-01-01

    This research has developed an integrated set of tools, called Disciple 2008 learning agent shell, for continuous acquisition of knowledge directly from subject matter experts, and for the integration...

  14. 1024-65536 channel nuclear spectrum data acquisition and processing system

    Energy Technology Data Exchange (ETDEWEB)

    Songjiang, Xia

    1987-09-01

    A multiscale data acquisition and processing system based on IBM PC/XT microcomputer is described. In this system, not only 1024,2048,4096 single parameter spectrum, but also 128 x 128, 256 x 256 dual parameter spectrum can be acquisited. The interface logic is designed to work at sequential recording DMA mode, the total avergage time for recording each descriptor is 7.5 ..mu..s.

  15. Assess the Critical Period Hypothesis in Second Language Acquisition

    Science.gov (United States)

    Du, Lihong

    2010-01-01

    The Critical Period Hypothesis aims to investigate the reason for significant difference between first language acquisition and second language acquisition. Over the past few decades, researchers carried out a series of studies to test the validity of the hypothesis. Although there were certain limitations in these studies, most of their results…

  16. Acquisition system of tandem injector parameters

    International Nuclear Information System (INIS)

    Decourt, M.

    1986-01-01

    The system centralizes all the parameters belonging to the accelerator injector. The acquisition center system reinforces an original device made of cameras and video receivers. Besides giving access to all the parameters of the ion source, the new system allows, in the ''OSCILLO'' mode, to visualize in real time any channel on the oscilloscope [fr

  17. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    Directory of Open Access Journals (Sweden)

    Dariusz Wroblewski

    2014-01-01

    Full Text Available Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1 manual, with patient response registered with a mouse click, and (2 visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1 minimal systematic differences between measurements taken in visual grasp and manual modes, (2 the average standard deviation of the difference distributions of about 5 dB, and (3 a systematic shift (of 4–6 dB to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients’ acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  18. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    Science.gov (United States)

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  19. Do international acquisitions by emerging-economy firms create shareholder value? The case of Indian firms

    NARCIS (Netherlands)

    Gubbi, Sathyajit R.; Aulakh, Preet S.; Ray, Sougata; Sarkar, M. B.; Chittoor, Raveendra

    While overseas acquisitions by emerging-economy firms are gaining increased attention from the business press, our understanding of whether and why this inorganic mode of international expansion creates value to acquirer firms is limited. We argue that international acquisitions facilitate

  20. An asynchronous, pipelined, electronic acquisition system for Active Matrix Flat-Panel Imagers (AMFPIs)

    Energy Technology Data Exchange (ETDEWEB)

    Huang, W.; Antonuk, L.E. E-mail: antonuk@umich.edu; Berry, J.; Maolinbay, M.; Martelli, C.; Mody, P.; Nassif, S.; Yeakey, M

    1999-07-11

    The development of a full-custom electronic acquisition system designed for readout of large-area active matrix flat-panel imaging arrays is reported. The arrays, which comprise two-dimensional matrices of pixels utilizing amorphous silicon thin-film transistors, are themselves under development for a wide variety of X-ray imaging applications. The acquisition system was specifically designed to facilitate detailed, quantitative investigations of the properties of these novel imaging arrays and contains significant enhancements compared to a previously developed acquisition system. These enhancements include pipelined preamplifier circuits to allow faster readout speed, expanded addressing capabilities allowing a maximum of 4096 array data lines, and on-board summing of image frames. The values of many acquisition system parameters, including timings and voltages, may be specified and downloaded from a host computer. Once acquisition is enabled, the system operates asynchronously of its host computer. The system allows image capture in both radiographic mode (corresponding to the capture of individual X-ray images), and fluoroscopic mode (corresponding to the capture of a continual series of X-ray images). A detailed description of the system architecture and the underlying motivations for the design is reported in this paper. (author)

  1. Alternate mode for data acquisition and real-time monitoring system based on CAMAC system

    International Nuclear Information System (INIS)

    Luo, J.R.; Wei, P.J.; Li, G.M.; Wang, H.

    2006-01-01

    Long discharges (about 250 s) have been achieved on HT-7 tokamak experiments in the Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). And in the next generation tokamaks like ITER , KSTAR and EAST , the pulses will be about 1000 s. In such steady-state operation, we have to upgrade the CAMAC-based data acquisition system, with higher sampling rates and longer acquisition times. It is necessary to monitor the plasma parameters in real-time so that the operators can change the operational conditions during the discharge to maintain the plasma. A design of the system named alternant data acquisition and real-time monitoring system for steady-state tokamak operation based on CAMAC system has been setup in ASIPP. The application of this system has been demonstrated in the HT-7 and TRIAM-1M tokamaks during their 2004 experiment campaigns

  2. Improved diagnostic accuracy of Alzheimer's disease by combining regional cortical thickness and default mode network functional connectivity: Validated in the Alzheimer's disease neuroimaging initiative set

    International Nuclear Information System (INIS)

    Park, Ji Eun; Park, Bum Woo; Kim, Sang Joon; Kim, Ho Sung; Choi, Choong Gon; Jung, Seung Jung; Oh, Joo Young; Shim, Woo Hyun; Lee, Jae Hong; Roh, Jee Hoon

    2017-01-01

    To identify potential imaging biomarkers of Alzheimer's disease by combining brain cortical thickness (CThk) and functional connectivity and to validate this model's diagnostic accuracy in a validation set. Data from 98 subjects was retrospectively reviewed, including a study set (n = 63) and a validation set from the Alzheimer's Disease Neuroimaging Initiative (n = 35). From each subject, data for CThk and functional connectivity of the default mode network was extracted from structural T1-weighted and resting-state functional magnetic resonance imaging. Cortical regions with significant differences between patients and healthy controls in the correlation of CThk and functional connectivity were identified in the study set. The diagnostic accuracy of functional connectivity measures combined with CThk in the identified regions was evaluated against that in the medial temporal lobes using the validation set and application of a support vector machine. Group-wise differences in the correlation of CThk and default mode network functional connectivity were identified in the superior temporal (p < 0.001) and supramarginal gyrus (p = 0.007) of the left cerebral hemisphere. Default mode network functional connectivity combined with the CThk of those two regions were more accurate than that combined with the CThk of both medial temporal lobes (91.7% vs. 75%). Combining functional information with CThk of the superior temporal and supramarginal gyri in the left cerebral hemisphere improves diagnostic accuracy, making it a potential imaging biomarker for Alzheimer's disease

  3. Impedance Eduction in Large Ducts Containing Higher-Order Modes and Grazing Flow

    Science.gov (United States)

    Watson, Willie R.; Jones, Michael G.

    2017-01-01

    Impedance eduction test data are acquired in ducts with small and large cross-sectional areas at the NASA Langley Research Center. An improved data acquisition system in the large duct has resulted in increased control of the acoustic energy in source modes and more accurate resolution of higher-order duct modes compared to previous tests. Two impedance eduction methods that take advantage of the improved data acquisition to educe the liner impedance in grazing flow are presented. One method measures the axial propagation constant of a dominant mode in the liner test section (by implementing the Kumarsean and Tufts algorithm) and educes the impedance from an exact analytical expression. The second method solves numerically the convected Helmholtz equation and minimizes an objective function to obtain the liner impedance. The two methods are tested first on data synthesized from an exact mode solution and then on measured data. Results show that when the methods are applied to data acquired in the larger duct with a dominant higher-order mode, the same impedance spectra are educed as that obtained in the small duct where only the plane wave mode propagates. This result holds for each higher-order mode in the large duct provided that the higher-order mode is sufficiently attenuated by the liner.

  4. Design and application of pulse information acquisition and analysis ...

    African Journals Online (AJOL)

    ... two-dimensional information acquisition, multiplex signals combination and deep data mining. Conclusions: The newly developed system could translate the pulse signals into digital, visual and measurable motion information of vessel. Keywords: Visualized pulse information; Radial artery; B mode ultrasound; Traditional ...

  5. Acquisition of Uropygial Gland Microbiome by Hoopoe Nestlings.

    Science.gov (United States)

    Martín-Vivaldi, Manuel; Soler, Juan José; Martínez-García, Ángela; Arco, Laura; Juárez-García-Pelayo, Natalia; Ruiz-Rodríguez, Magdalena; Martínez-Bueno, Manuel

    2017-12-18

    Mutualistic symbioses between animals and bacteria depend on acquisition of appropriate symbionts while avoiding exploitation by non-beneficial microbes. The mode of acquisition of symbionts would determine, not only the probability of encountering but also evolutionary outcomes of mutualistic counterparts. The microbiome inhabiting the uropygial gland of the European hoopoe (Upupa epops) includes a variety of bacterial strains, some of them providing antimicrobial benefits. Here, the mode of acquisition and stability of this microbiome is analyzed by means of Automated rRNA Intergenic Spacer Analysis and two different experiments. The first experiment impeded mothers' access to their glands, thus avoiding direct transmission of microorganisms from female to offspring secretions. The second experiment explored the stability of the microbiomes by inoculating glands with secretions from alien nests. The first experiment provoked a reduction in similarity of microbiomes of mother and nestlings. Interestingly, some bacterial strains were more often detected when females had not access to their glands, suggesting antagonistic effects among bacteria from different sources. The second experiment caused an increase in richness of the microbiome of receivers in terms of prevalence of Operational Taxonomic Units (OTUs) that reduced differences in microbiomes of donors and receivers. That occurred because OTUs that were present in donors but not in receivers incorporated to the microbiome of the latter, which provoked that cross-inoculated nestlings got similar final microbiomes that included the most prevalent OTUs. The results are therefore consistent with a central role of vertical transmission in bacterial acquisition by nestling hoopoes and support the idea that the typical composition of the hoopoe gland microbiome is reached by the incorporation of some bacteria during the nestling period. This scenario suggests the existence of a coevolved core microbiome composed by

  6. Integration of the trigger and data acquisition systems in ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Abolins, M [Michigan State University, Department of Physics and Astronomy, East Lansing, Michigan (United States); Adragna, P [Department of Physics, Queen Mary and Westfield College, University of London, London (United Kingdom); Aleksandrov, E; Aleksandrov, I [Joint Institute for Nuclear Research, Dubna (Russian Federation); Amorim, A [Laboratorio de Instrumentacao e Fisica Experimental, Lisboa (Portugal); Anderson, K [University of Chicago, Enrico Fermi Institute, Chicago, Illinois (United States); Anduaga, X [National University of La Plata, La Plata (United States); Aracena, I; Bartoldus, R [Stanford Linear Accelerator Center (SLAC), Stanford (United States); Asquith, L [Department of Physics and Astronomy, University College London, London (United Kingdom); Avolio, G; Backlund, S [European Laboratory for Particle Physics (CERN), Geneva (Switzerland); Badescu, E [National Institute for Physics and Nuclear Engineering, Institute of Atomic Physics, Bucharest (Romania); Baines, J [Rutherford Appleton Laboratory, Chilton, Didcot (United Kingdom); Beck, H P [Laboratory for High Energy Physics, University of Bern, Bern (Switzerland); Bee, C [Centre de Physique des Particules de Marseille, IN2P3-CNRS, Marseille (France); Bell, P [Department of Physics and Astronomy, University of Manchester, Manchester (United Kingdom); Bell, W H [Department of Physics and Astronomy, University of Glasgow, Glasgow (United Kingdom); Barria, P; Batreanu, S [and others

    2008-07-01

    During 2006 and the first half of 2007, the installation, integration and commissioning of trigger and data acquisition (TDAQ) equipment in the ATLAS experimental area have progressed. There have been a series of technical runs using the final components of the system already installed in the experimental area. Various tests have been run including ones where level 1 preselected simulated proton-proton events have been processed in a loop mode through the trigger and dataflow chains. The system included the readout buffers containing the events, event building, level 2 and event filter trigger algorithms. The scalability of the system with respect to the number of event building nodes used has been studied and quantities critical for the final system, such as trigger rates and event processing times, have been measured using different trigger algorithms as well as different TDAQ components. This paper presents the TDAQ architecture, the current status of the installation and commissioning and highlights the main test results that validate the system.

  7. Integration of the trigger and data acquisition systems in ATLAS

    International Nuclear Information System (INIS)

    Abolins, M; Adragna, P; Aleksandrov, E; Aleksandrov, I; Amorim, A; Anderson, K; Anduaga, X; Aracena, I; Bartoldus, R; Asquith, L; Avolio, G; Backlund, S; Badescu, E; Baines, J; Beck, H P; Bee, C; Bell, P; Bell, W H; Barria, P; Batreanu, S

    2008-01-01

    During 2006 and the first half of 2007, the installation, integration and commissioning of trigger and data acquisition (TDAQ) equipment in the ATLAS experimental area have progressed. There have been a series of technical runs using the final components of the system already installed in the experimental area. Various tests have been run including ones where level 1 preselected simulated proton-proton events have been processed in a loop mode through the trigger and dataflow chains. The system included the readout buffers containing the events, event building, level 2 and event filter trigger algorithms. The scalability of the system with respect to the number of event building nodes used has been studied and quantities critical for the final system, such as trigger rates and event processing times, have been measured using different trigger algorithms as well as different TDAQ components. This paper presents the TDAQ architecture, the current status of the installation and commissioning and highlights the main test results that validate the system

  8. Integration of the Trigger and Data Acquisition Systems in ATLAS

    International Nuclear Information System (INIS)

    Abolins, M.; Adragna, P.; Aleksandrov, E.; Aleksandrov, I.; Amorim, A.; Anderson, K.; Anduaga, X.; Aracena, I.; Asquith, L.; Avolio, G.; Backlund, S.; Badescu, E.; Baines, J.; Barria, P.; Bartoldus, R.; Batreanu, S.; Beck, H.P.; Bee, C.; Bell, P.; Bell, W.H.; Bellomo, M.

    2011-01-01

    During 2006 and the first half of 2007, the installation, integration and commissioning of trigger and data acquisition (TDAQ) equipment in the ATLAS experimental area have progressed. There have been a series of technical runs using the final components of the system already installed in the experimental area. Various tests have been run including ones where level 1 preselected simulated proton-proton events have been processed in a loop mode through the trigger and dataflow chains. The system included the readout buffers containing the events, event building, level 2 and event filter trigger algorithms. The scalability of the system with respect to the number of event building nodes used has been studied and quantities critical for the final system, such as trigger rates and event processing times, have been measured using different trigger algorithms as well as different TDAQ components. This paper presents the TDAQ architecture, the current status of the installation and commissioning and highlights the main test results that validate the system.

  9. Research and Application of WCF Technology in Data Acquisition of Ultra-high Speed Packaging Machine

    Directory of Open Access Journals (Sweden)

    Qian Jie

    2016-01-01

    Full Text Available By introducing WCF technology on data acquisition of ultra-high speed packaging machine, data acquisition system reads dates of machine in polling mode through the WCF client, which can achieve accurate data collection, and effectively isolate the data acquisition system and the machine control system. It enhances the security of data interaction between systems, but also reduces the coupling degree between systems.

  10. Software programmable multi-mode interface for nuclear-medical imaging

    International Nuclear Information System (INIS)

    Zubal, I.G.; Rowe, R.W.; Bizais, Y.J.C.; Bennett, G.W.; Brill, A.B.

    1982-01-01

    An innovative multi-port interface allows gamma camera events (spatial coordinates and energy) to be acquired concurrently with a sampling of physiological patient data. The versatility of the interface permits all conventional static, dynamic, and tomographic imaging modes, in addition to multi-hole coded aperture acquisition. The acquired list mode data may be analyzed or gated on the basis of various camera, isotopic, or physiological parameters

  11. Hypertext Glosses for Foreign Language Reading Comprehension and Vocabulary Acquisition: Effects of Assessment Methods

    Science.gov (United States)

    Chen, I-Jung

    2016-01-01

    This study compared how three different gloss modes affected college students' L2 reading comprehension and vocabulary acquisition. The study also compared how results on comprehension and vocabulary acquisition may differ depending on the four assessment methods used. A between-subjects design was employed with three groups of Mandarin-speaking…

  12. Development of data acquisition software for VME based system

    International Nuclear Information System (INIS)

    Kumar, A.; Chatterjee, A.; Mahata, K.; Ramachandran, K.

    2012-01-01

    A data acquisition system for VME has been developed for use in accelerator based experiments. The development was motivated by the growing demand for higher throughput in view of the increasing size of experiments. VME based data acquisition system provides a powerful alternative to CAMAC standards on account of higher readout speeds (100 ns/word) resulting in reduced dead time. Further, high density VME modules are capable of providing up to 640 channels in a single VME crate with 21 slots. The software system LAMPS, earlier developed for CAMAC based system and used extensively in our laboratory and elsewhere has been modified for the present VME based system. The system makes use of the VME library to implement Chain Block Transfer Readout (CBLT) and gives the option of both Polling and Interrupt mode to acquire data. Practical throughput of ∼ 250 ns/word in zero suppressed mode has been achieved. (author)

  13. Validation of the schema mode concept in personality disordered offenders

    NARCIS (Netherlands)

    Marije Keulen-de Vos; David P. Bernstein; Lee Anna Clark; Vivienne de Vogel; Stefan Bogaerts; Mariëtte Slaats; Arnoud Arntz

    2017-01-01

    A core element of Schema Therapy (ST) is ‘schema modes’ or fluctuating emotional states. ST assumes that particular personality pathology consists of specific combinations of maladaptive schema modes. There is confirmatory evidence for the modes hypothesized to be central to borderline and

  14. 3D Data Acquisition Platform for Human Activity Understanding

    Science.gov (United States)

    2016-03-02

    SECURITY CLASSIFICATION OF: In this project, we incorporated motion capture devices, 3D vision sensors, and EMG sensors to cross validate...multimodality data acquisition, and address fundamental research problems of representation and invariant description of 3D data, human motion modeling and...applications of human activity analysis, and computational optimization of large-scale 3D data. The support for the acquisition of such research

  15. Validation of the schema mode concept in personality disordered offenders

    NARCIS (Netherlands)

    Keulen-de Vos, M.; Bernstein, D.P.; Clark, L.A.; de Vogel, V.; Bogaerts, S.; Slaats, M.; Arntz, A.

    Purpose: A core element of Schema Therapy (ST) is ‘schema modes’ or fluctuating emotional states. ST assumes that particular personality pathology consists of specific combinations of maladaptive schema modes. There is confirmatory evidence for the modes hypothesized to be central to borderline and

  16. Identification of multiple modes of axisymmetric or circularly repetitive structures

    International Nuclear Information System (INIS)

    Kopff, P.

    1983-01-01

    The axisymmetric structures, or those composed with circularly repetitive elements, often display multiple modes, which are not easy to separate by modal identification of experimental responses. To be able to solve in situ some problems related to the vibrational behaviour of reactor vessels or other such huge structures, ELECTRICITY DE FRANCE developed a few years ago, experimental capabilities providing heavy harmonic driving forces, and elaborate data acquisition, signal processing and modal identification software, self-contained in an integrated mobile test facility. The modal analysis techniques we have developed with the LABORATOIRE DE MECANIQUE Appliquee of University of BESANCON (FRANCE) were especially suited for identification of multiple or separation of quasi-multiple modes, i.e. very close and strongly coupled resonances. Besides, the curve fitting methods involved, compute the same complex eigen-frequencies for all the vibration pick-ups, for better accuracy of the related eigen-vector components. Moreover, the latest extensions of these algorithms give us the means to deal with non-linear behaviour. The performances of these programs are drawn from some experimental results on axisymmetric or circularly repetitive structure, we tested in our laboratory to validate the computational hypothesis used in models for seismic responses of breeder reactor vessels. (orig.)

  17. Data acquisition software for the CMS strip tracker

    International Nuclear Information System (INIS)

    Bainbridge, R; Cripps, N; Fulcher, J; Radicci, V; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Gill, K; Mirabito, L; Cole, J; Jesus, A C A; Giassi, A; Giordano, D; Gross, L; Hahn, K; Mersi, S; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS silicon strip tracker, providing a sensitive area of approximately 200 m 2 and comprising 10 million readout channels, has recently been completed at the tracker integration facility at CERN. The strip tracker community is currently working to develop and integrate the online and offline software frameworks, known as XDAQ and CMSSW respectively, for the purposes of data acquisition and detector commissioning and monitoring. Recent developments have seen the integration of many new services and tools within the online data acquisition system, such as event building, online distributed analysis, an online monitoring framework, and data storage management. We review the various software components that comprise the strip tracker data acquisition system, the software architectures used for stand-alone and global data-taking modes. Our experiences in commissioning and operating one of the largest ever silicon micro-strip tracking systems are also reviewed

  18. Adaptation of the modified Bouc–Wen model to compensate for hysteresis in respiratory motion for the list-mode binning of cardiac SPECT and PET acquisitions: Testing using MRI

    International Nuclear Information System (INIS)

    Dasari, Paul K. R.; Shazeeb, Mohammed Salman; Könik, Arda; Lindsay, Clifford; Mukherjee, Joyeeta M.; Johnson, Karen L.; King, Michael A.

    2014-01-01

    Purpose: Binning list-mode acquisitions as a function of a surrogate signal related to respiration has been employed to reduce the impact of respiratory motion on image quality in cardiac emission tomography (SPECT and PET). Inherent in amplitude binning is the assumption that there is a monotonic relationship between the amplitude of the surrogate signal and respiratory motion of the heart. This assumption is not valid in the presence of hysteresis when heart motion exhibits a different relationship with the surrogate during inspiration and expiration. The purpose of this study was to investigate the novel approach of using the Bouc–Wen (BW) model to provide a signal accounting for hysteresis when binning list-mode data with the goal of thereby improving motion correction. The study is based on the authors’ previous observations that hysteresis between chest and abdomen markers was indicative of hysteresis between abdomen markers and the internal motion of the heart. Methods: In 19 healthy volunteers, they determined the internal motion of the heart and diaphragm in the superior–inferior direction during free breathing using MRI navigators. A visual tracking system (VTS) synchronized with MRI acquisition tracked the anterior–posterior motions of external markers placed on the chest and abdomen. These data were employed to develop and test the Bouc–Wen model by inputting the VTS derived chest and abdomen motions into it and using the resulting output signals as surrogates for cardiac motion. The data of the volunteers were divided into training and testing sets. The training set was used to obtain initial values for the model parameters for all of the volunteers in the set, and for set members based on whether they were or were not classified as exhibiting hysteresis using a metric derived from the markers. These initial parameters were then employed with the testing set to estimate output signals. Pearson’s linear correlation coefficient between the

  19. Enhancement of graphic user interface data acquisition of small angle neutron scattering

    International Nuclear Information System (INIS)

    Abd Aziz Muhammad; Abd Jalil Abd Hamid

    2004-01-01

    This paper discusses the activities of the development of data acquisition software for PC, which capable of controlling instrument via IEEE-488 and graphic visualization for small angle neutron scattering (SANS) runs in DOS mode. With the help of outstanding free ware graphic library for DOS, this software has enhanced the efficiency of graphic visualization for SANSLab data acquisition. Featuring easy-to-use graphical user interface (GUI) and several other built-in tools for convenience, this software can be manipulated with the mouse or the keyboard. This software can be converted into an inexpensive data acquisition system for SANS. (Author)

  20. Next generation PET data acquisition architectures

    Science.gov (United States)

    Jones, W. F.; Reed, J. H.; Everman, J. L.; Young, J. W.; Seese, R. D.

    1997-06-01

    New architectures for higher performance data acquisition in PET are proposed. Improvements are demanded primarily by three areas of advancing PET state of the art. First, larger detector arrays such as the Hammersmith ECAT/sup (R/) EXACT HR/sup ++/ exceed the addressing capacity of 32 bit coincidence event words. Second, better scintillators (LSO) make depth-of interaction (DOI) and time-of-flight (TOF) operation more practical. Third, fully optimized single photon attenuation correction requires higher rates of data collection. New technologies which enable the proposed third generation Real Time Sorter (RTS III) include: (1) 80 Mbyte/sec Fibre Channel RAID disk systems, (2) PowerPC on both VMEbus and PCI Local bus, and (3) quadruple interleaved DRAM controller designs. Data acquisition flexibility is enhanced through a wider 64 bit coincidence event word. PET methodology support includes DOI (6 bits), TOF (6 bits), multiple energy windows (6 bits), 512/spl times/512 sinogram indexes (18 bits), and 256 crystal rings (16 bits). Throughput of 10 M events/sec is expected for list-mode data collection as well as both on-line and replay histogramming. Fully efficient list-mode storage for each PET application is provided by real-time bit packing of only the active event word bits. Real-time circuits provide DOI rebinning.

  1. Next generation PET data acquisition architectures

    International Nuclear Information System (INIS)

    Jones, W.F.; Reed, J.H.; Everman, J.L.

    1996-01-01

    New architectures for higher performance data acquisition in PET are proposed. Improvements are demanded primarily by three areas of advancing PET state of the art. First, larger detector arrays such as the Hammersmith ECAT reg-sign EXACT HR ++ exceed the addressing capacity of 32 bit coincidence event words. Second, better scintillators (LSO) make depth-of-interaction (DOI) and time-of-flight (TOF) operation more practical. Third, fully optimized single photon attenuation correction requires higher rates of data collection. New technologies which enable the proposed third generation Real Time Sorter (RTS III) include: (1) 80 M byte/sec Fibre Channel RAID disk systems, (2) PowerPC on both VMEbus and PCI Local bus, and (3) quadruple interleaved DRAM controller designs. Data acquisition flexibility is enhanced through a wider 64 bit coincidence event word. PET methodology support includes DOI (6 bits), TOF (6 bits), multiple energy windows (6 bits), 512 x 512 sinogram indexes (18 bits), and 256 crystal rings (16 bits). Throughput of 10 M events/sec is expected for list-mode data collection as well as both on-line and replay histogramming. Fully efficient list-mode storage for each PET application is provided by real-time bit packing of only the active event word bits. Real-time circuits provide DOI rebinning

  2. Network on chip master control board for neutron acquisition

    International Nuclear Information System (INIS)

    Ruiz-Martinez, E.; Mary, T.; Mutti, P.; Ratel, J.; Rey, F.

    2012-01-01

    The acquisition master control board is designed to assemble the various acquisition modes in use at the Institut Laue-Langevin (ILL). The main goal is to make the card common for all the ILL's instruments in a simple, modular and open way, giving the possibility to add new functionalities in order to follow the evolving demand. It has been necessary to define a central element to provide synchronization to the rest of the units. The backbone of the proposed acquisition control system is the denominated master acquisition board. The master board consists on a VME64X configurable high density I/O connection carrier board based on the latest Xilinx Virtex-6T FPGA. The internal architecture of the FPGA is designed as a Network on Chip (NoC) approach. The complete system also includes a display board and n histogram modules for live display of the data from the detectors. (authors)

  3. PC based 8-parameter data acquisition system

    International Nuclear Information System (INIS)

    Gupta, J.D.; Naik, K.V.; Jain, S.K.; Pathak, R.V.; Suman, B.

    1989-01-01

    Multiparameter data acquisition (MPA) systems which analyse nuclear events with respect to more than one property of the event are essential tools for the study of some complex nuclear phenomena requiring analysis of time coincident spectra. For better throughput and accuracy each parameter is digitized by its own ADC. A stand alone low cost IBM PC based 8-parameter data acquisition system developed by the authors makes use of Address Recording technique for acquiring data from eight 12 bit ADC's in the PC Memory. Two memory buffers in the PC memory are used in ping-pong fashion so that data acquisition in one bank and dumping of data onto PC disk from the other bank can proceed simultaneously. Data is acquired in the PC memory through DMA mode for realising high throughput and hardware interrupt is used for switching banks for data acquisition. A comprehensive software package developed in Turbo-Pascal offers a set of menu-driven interactive commands to the user for setting-up system parameters and control of the system. The system is to be used with pelletron accelerator. (author). 5 figs

  4. Validation of the Predicted Circumferential and Radial Mode Sound Power Levels in the Inlet and Exhaust Ducts of a Fan Ingesting Distorted Inflow

    Science.gov (United States)

    Koch, L. Danielle

    2012-01-01

    Fan inflow distortion tone noise has been studied computationally and experimentally. Data from two experiments in the NASA Glenn Advanced Noise Control Fan rig have been used to validate acoustic predictions. The inflow to the fan was distorted by cylindrical rods inserted radially into the inlet duct one rotor chord length upstream of the fan. The rods were arranged in both symmetric and asymmetric circumferential patterns. In-duct and farfield sound pressure level measurements were recorded. It was discovered that for positive circumferential modes, measured circumferential mode sound power levels in the exhaust duct were greater than those in the inlet duct and for negative circumferential modes, measured total circumferential mode sound power levels in the exhaust were less than those in the inlet. Predicted trends in overall sound power level were proven to be useful in identifying circumferentially asymmetric distortion patterns that reduce overall inlet distortion tone noise, as compared to symmetric arrangements of rods. Detailed comparisons between the measured and predicted radial mode sound power in the inlet and exhaust duct indicate limitations of the theory.

  5. Data acquisition and treatment unit for use in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Annaix, C; Prieur, G; Vilayleck, S; Jallet, P [C.H.R., Angers (France)

    1981-01-01

    Here is below a one-channel data acquisition unit piloted through a minicomputer programmed by means of an advanced language of the Basic type. This unit allows, especially in nuclear medicine, pulse counts from a spectrometer according to a programmed sequence. Moreover, it provides treatment of measures as well as printing and filing of interpreted results. The acquisition unit is linked to the minicomputer through a RS 232 C serial mode, which ensures both easy operation and universal use of the system here described. Accuracy of measurement is also examined.

  6. The current state of the market for corporate acquisitions

    International Nuclear Information System (INIS)

    Korpach, A.N.

    1998-01-01

    The main factors which determine when the oil and gas industry is in a seller's market or a buyer's market mode were discussed. In a seller's market, the number of potential buyers for assets exceeds the number of sellers. Therefore, sellers could obtain good prices for their assets. Such was the case from 1995 to 1997. For 1998, the level of merger and acquisition activity was high and is expected to remain strong for 1999, but the market appears to be firmly a buyer's market (more sellers than potential buyers). The reasons for this are as follows: (1) restricted access to capital, (2) declining stock prices/values, (3) significant supply of assets, and (4) acquisition costs now in line with finding and development costs. The question of whether or not acquisitions add value was also discussed. It was noted that share price performance of those companies making acquisitions during the period was comparable to that of the TSE oil and gas producers index. A list of some Canadian and U.S. companies which completed significant acquisitions in 1997 and 1998 was included. 10 figs

  7. An embedded control and acquisition system for multichannel detectors

    International Nuclear Information System (INIS)

    Gori, L.; Tommasini, R.; Cautero, G.; Giuressi, D.; Barnaba, M.; Accardo, A.; Carrato, S.; Paolucci, G.

    1999-01-01

    We present a pulse counting multichannel data acquisition system, characterized by the high number of high speed acquisition channels, and by the modular, embedded system architecture. The former leads to very fast acquisitions and allows to obtain sequences of snapshots, for the study of time dependent phenomena. The latter, thanks to the integration of a CPU into the system, provides high computational capabilities, so that the interfacing with the user computer is very simple and user friendly. Moreover, the user computer is free from control and acquisition tasks. The system has been developed for one of the beamlines of the third generation synchrotron radiation sources ELETTRA, and because of the modular architecture can be useful in various other kinds of experiments, where parallel acquisition, high data rates, and user friendliness are required. First experimental results on a double pass hemispherical electron analyser provided with a 96 channel detector confirm the validity of the approach. (author)

  8. Control system design for the constellation acquisition phase of the LISA mission

    Energy Technology Data Exchange (ETDEWEB)

    Cirillo, Francesca; Gath, Peter F, E-mail: francesca.cirillo@astrium.eads.ne, E-mail: peter.gath@astrium.eads.ne [Astrium GmbH Satellites, 88039 Friedrichshafen (Germany)

    2009-03-01

    The objective of the constellation acquisition phase for the LISA mission is to establish the three laser links between the three spacecraft of the LISA constellation so that the interferometric measurements for the science experiment can commence. The laser beam acquisition for LISA is extremely challenging given the 5 million km distance between the spacecraft, the inherent limits of the attitude sensors accuracy, the orbit determination accuracy issues and the time required to phase-lock the incoming and outgoing laser signals. This paper presents the design of the control system for the acquisition phase of the LISA constellation: the acquisition operational procedure is outlined, guidance laws are defined together with the Gyro Mode attitude control principle, which implements a Kalman filter for disturbances rejection purposes. Constellation-wide non-linear simulations demonstrate that the LISA constellation acquisition phase is feasible by means of the proposed control strategy.

  9. Control system design for the constellation acquisition phase of the LISA mission

    International Nuclear Information System (INIS)

    Cirillo, Francesca; Gath, Peter F

    2009-01-01

    The objective of the constellation acquisition phase for the LISA mission is to establish the three laser links between the three spacecraft of the LISA constellation so that the interferometric measurements for the science experiment can commence. The laser beam acquisition for LISA is extremely challenging given the 5 million km distance between the spacecraft, the inherent limits of the attitude sensors accuracy, the orbit determination accuracy issues and the time required to phase-lock the incoming and outgoing laser signals. This paper presents the design of the control system for the acquisition phase of the LISA constellation: the acquisition operational procedure is outlined, guidance laws are defined together with the Gyro Mode attitude control principle, which implements a Kalman filter for disturbances rejection purposes. Constellation-wide non-linear simulations demonstrate that the LISA constellation acquisition phase is feasible by means of the proposed control strategy.

  10. A multi-parameter, acquisition system positron annihilation lifetime spectrometer

    International Nuclear Information System (INIS)

    Sharshar, T.

    2004-01-01

    A positron annihilation lifetime spectrometer employing a multi-parameter acquisition system has been prepared for various purposes such as the investigation and characterization of solid-state materials. The fast-fast coincidence technique was used in the present spectrometer with a pair of plastic scintillation detectors. The acquisition system is based on the Kmax software and on CAMAC modules. The data are acquired in event-by-event list mode. The time spectrum for the desired energy windows can be obtained by off-line data sorting and analysis. The spectrometer for event-by-event data acquisition is an important step to construct a positron age-momentum correlation (AMOC) spectrometer. The AMOC technique is especially suited for the observation of positron transitions between different states during their lifetime. The system performance was tested and the results were presented and discussed

  11. The entry mode choice of EU leading companies (1987-1997)

    OpenAIRE

    Giampaolo Vitali

    1999-01-01

    The aim of the paper is to provide empirical evidence on the relationship between industrial structure and M&A process. We focus on the determining factors fostering a firm to choose controlling acquisitions or non-controlling ones. We use the Acquisitions and Divestments Database (ADD), a data-base collecting equity operations made by top-90 EU leaders in the period 1987-1997. A logit analysis shows some variables that increase the probability that the firm’s entry mode choice is a non-contr...

  12. The blood-pool technique of radionuclide ventriculography: Data acquisition and evaluation

    International Nuclear Information System (INIS)

    Mueller-Schauenburg, W.

    1986-01-01

    For gated heart studies an in-vitro-labelling of erythrocytes is commonly used. Rest and exercise studies are acquired from LAO. Complementary studies may have different views. Besides the most common direct frame mode acquisition, there are the more flexible list mode and a hybrid mode. Concerning evaluation the ejection fraction is the leading parameter of global ventricular analysis. In local analysis a pixelwise evaluation generates functional images of phases and amplitudes (the Fourier approach developed by the Ulm group) or Noelep's trend images. Special attention has to be paid to the varying cycle length when a sine or cosine fitting (Fourier) is used for curve smoothing or phase and amplitude images. There are two opposed problems: If there are undetected QRS-complexes, the end of the representative cycle will contain early phases of subsequent cycles which must be cut off. In the case of really varying cycle length, the last images of the representative cycle must be corrected for acquisition time per frame. The total count curve may help to discriminate both cases and supplies suitable correction factors in the latter case. (orig.) [de

  13. The Data Acquisition and Calibration System for the ATLAS Semiconductor Tracker

    CERN Document Server

    Abdesselam, A; Barr, A J; Bell, P; Bernabeu, J; Butterworth, J M; Carter, J R; Carter, A A; Charles, E; Clark, A; Colijn, A P; Costa, M J; Dalmau, J M; Demirkoz, B; Dervan, P J; Donega, M; D'Onifrio, M; Escobar, C; Fasching, D; Ferguson, D P S; Ferrari, P; Ferrère, D; Fuster, J; Gallop, B; García, C; González, S; González-Sevilla, S; Goodrick, M J; Gorisek, A; Greenall, A; Grillo, A A; Hessey, N P; Hill, J C; Jackson, J N; Jared, R C; Johannson, P D C; de Jong, P; Joseph, J; Lacasta, C; Lane, J B; Lester, C G; Limper, M; Lindsay, S W; McKay, R L; Magrath, C A; Mangin-Brinet, M; Martí i García, S; Mellado, B; Meyer, W T; Mikulec, B; Minano, M; Mitsou, V A; Moorhead, G; Morrissey, M; Paganis, E; Palmer, M J; Parker, M A; Pernegger, H; Phillips, A; Phillips, P W; Postranecky, M; Robichaud-Véronneau, A; Robinson, D; Roe, S; Sandaker, H; Sciacca, F; Sfyrla, A; Stanecka, E; Stapnes, S; Stradling, A; Tyndel, M; Tricoli, A; Vickey, T; Vossebeld, J H; Warren, M R M; Weidberg, A R; Wells, P S; Wu, S L

    2008-01-01

    The SemiConductor Tracker (SCT) data acquisition (DAQ) system will calibrate, configure, and control the approximately six million front-end channels of the ATLAS silicon strip detector. It will provide a synchronized bunch-crossing clock to the front-end modules, communicate first-level triggers to the front-end chips, and transfer information about hit strips to the ATLAS high-level trigger system. The system has been used extensively for calibration and quality assurance during SCT barrel and endcap assembly and for performance confirmation tests after transport of the barrels and endcaps to CERN. Operating in data-taking mode, the DAQ has recorded nearly twenty million synchronously-triggered events during commissioning tests including almost a million cosmic ray triggered events. In this paper we describe the components of the data acquisition system, discuss its operation in calibration and data-taking modes and present some detector performance results from these tests.

  14. The data acquisition and calibration system for the ATLAS Semiconductor Tracker

    International Nuclear Information System (INIS)

    Abdesselam, A; Barr, A J; Demirkoez, B; Barber, T; Carter, J R; Bell, P; Bernabeu, J; Costa, M J; Escobar, C; Butterworth, J M; Carter, A A; Dalmau, J M; Charles, E; Fasching, D; Ferguson, D P S; Clark, A; Donega, M; D'Onifrio, M; Colijn, A-P; Dervan, P J

    2008-01-01

    The SemiConductor Tracker (SCT) data acquisition (DAQ) system will calibrate, configure, and control the approximately six million front-end channels of the ATLAS silicon strip detector. It will provide a synchronized bunch-crossing clock to the front-end modules, communicate first-level triggers to the front-end chips, and transfer information about hit strips to the ATLAS high-level trigger system. The system has been used extensively for calibration and quality assurance during SCT barrel and endcap assembly and for performance confirmation tests after transport of the barrels and endcaps to CERN. Operating in data-taking mode, the DAQ has recorded nearly twenty million synchronously-triggered events during commissioning tests including almost a million cosmic ray triggered events. In this paper we describe the components of the data acquisition system, discuss its operation in calibration and data-taking modes and present some detector performance results from these tests

  15. Japanese subsidiaries in the European Union: Entry modes and performance

    Directory of Open Access Journals (Sweden)

    David Tanganelli

    2014-12-01

    Full Text Available Japanese Foreign Direct Investment (FDI in the European Union and its performance were analysed in this work. Three different FDI or entry modes used by Japanese companies to enter the European market were compared, and the presence of a relationship between the selected entry mode and the performance of the subsidiary was investigated. We found that more than half of the Japanese investments in Europe took the form of new ventures, approximately 40% were joint ventures and less than 6% were acquisitions. We found that no specific entry mode performed better than another.

  16. On global H-mode scaling laws for JET

    International Nuclear Information System (INIS)

    Kardaun, O.; Lackner, K.; Thomsen, K.; Christiansen, J.; Cordey, J.; Gottardi, N.; Keilhacker, M.; Smeulders, P.

    1989-01-01

    Investigation of the scaling of the energy confinement time τ E with various plasma parameters has since long been an interesting, albeit not uncontroversial topic in plasma physics. Various global scaling laws have been derived for ohmic as well as (NBI and/or RF heated) L-mode discharges. Due to the scarce availability of computerised, extensive and validated H-mode datasets, systematic statistical analysis of H-mode scaling behaviour has hitherto been limited. A common approach is to fit the available H-mode data by an L-mode scaling law (e.g., Kaye-Goldston, Rebut-Lallia) with one or two adjustable constant terms. In this contribution we will consider the alternative approach of fitting all free parameters of various simple scaling models to two recently compiled datasets consisting of about 140 ELM-free and 40 ELMy H-mode discharges, measured at JET in the period 1986-1988. From this period, approximately all known H-mode shots have been included that satisfy the following criteria: D-injected D + discharges with no RF heating, a sufficiently long (≥300 ms) and regular P NBI flat-top, and validated main diagnostics. (author) 13 refs., 1 tab

  17. Improved diagnostic accuracy of Alzheimer's disease by combining regional cortical thickness and default mode network functional connectivity: Validated in the Alzheimer's disease neuroimaging initiative set

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Eun; Park, Bum Woo; Kim, Sang Joon; Kim, Ho Sung; Choi, Choong Gon; Jung, Seung Jung; Oh, Joo Young; Shim, Woo Hyun [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Lee, Jae Hong; Roh, Jee Hoon [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    To identify potential imaging biomarkers of Alzheimer's disease by combining brain cortical thickness (CThk) and functional connectivity and to validate this model's diagnostic accuracy in a validation set. Data from 98 subjects was retrospectively reviewed, including a study set (n = 63) and a validation set from the Alzheimer's Disease Neuroimaging Initiative (n = 35). From each subject, data for CThk and functional connectivity of the default mode network was extracted from structural T1-weighted and resting-state functional magnetic resonance imaging. Cortical regions with significant differences between patients and healthy controls in the correlation of CThk and functional connectivity were identified in the study set. The diagnostic accuracy of functional connectivity measures combined with CThk in the identified regions was evaluated against that in the medial temporal lobes using the validation set and application of a support vector machine. Group-wise differences in the correlation of CThk and default mode network functional connectivity were identified in the superior temporal (p < 0.001) and supramarginal gyrus (p = 0.007) of the left cerebral hemisphere. Default mode network functional connectivity combined with the CThk of those two regions were more accurate than that combined with the CThk of both medial temporal lobes (91.7% vs. 75%). Combining functional information with CThk of the superior temporal and supramarginal gyri in the left cerebral hemisphere improves diagnostic accuracy, making it a potential imaging biomarker for Alzheimer's disease.

  18. Fluorescence quenching and the "ring-mode" to "red-mode" transition in alkali inductively coupled plasmas

    Science.gov (United States)

    Huang, M.; Bazurto, R.; Camparo, J.

    2018-01-01

    The ring-mode to red-mode transition in alkali metal inductively coupled plasmas (ICPs) (i.e., rf-discharge lamps) is perhaps the most important physical phenomenon affecting these devices as optical pumping light sources for atomic clocks and magnetometers. It sets the limit on useful ICP operating temperature, thereby setting a limit on ICP light output for atomic-clock/magnetometer signal generation, and it is a temperature region of ICP operation associated with discharge instability. Previous work has suggested that the mechanism driving the ring-mode to red-mode transition is associated with radiation trapping, but definitive experimental evidence validating that hypothesis has been lacking. Based on that hypothesis, one would predict that the introduction of an alkali-fluorescence quenching gas (i.e., N2) into the ICP would increase the ring-mode to red-mode transition temperature. Here, we test that prediction, finding direct evidence supporting the radiation-trapping hypothesis.

  19. The Representation of Bilingual Mental Lexicon and English Vocabulary Acquisition

    Science.gov (United States)

    Ying, Zhang

    2017-01-01

    This paper provides an overview of the theories on the organization and development of L1 mental lexicon and the representation mode of bilingual mental lexicon. It analyzes the structure and characteristics of Chinese EFL learners and their problems in English vocabulary acquisition. On the basis of this, it suggests that English vocabulary…

  20. Validation of a simultaneous PET/MR system model for PET simulation using GATE

    International Nuclear Information System (INIS)

    Monnier, Florian; Fayad, Hadi; Bert, Julien; Schmidt, Holger; Visvikis, Dimitris

    2015-01-01

    Simultaneous PET/MR acquisition shows promise in a range of applications. Simulation using GATE is an essential tool that allows obtaining the ground truth for such acquisitions and therefore helping in the development and the validation of innovative processing methods such as PET image reconstruction, attenuation correction and motion correction. The purpose of this work is to validate the GATE simulation of the Siemens Biograph mMR PET/MR system. A model of the Siemens Biograph mMR was developed. This model includes the geometry and spatial positioning of the crystals inside the scanner and the characteristics of the detection process. The accuracy of the model was tested by comparing, on a real physical phantom study, GATE simulated results to reconstructed PET images using measured results obtained from a Siemens Biograph mMR system. The same parameters such as the acquisition time and phantom position inside the scanner were fixed for our simulations. List-mode outputs were recovered in both cases and reconstructed using the OPL-EM algorithm. Several parameters were used to compare the two reconstructed images such as profile comparison, signal-to-noise ratio and activity contrast analysis. Finally patient acquired MR images were segmented and used for the simulation of corresponding PET images. The simulated and acquired sets of reconstructed phantom images showed close emission values in regions of interest with relative differences lower than 5%. The scatter fraction was within a <3% agreement. Close matching of profiles and contrast indices were obtained between simulated and corresponding acquired PET images. Our results indicate that the GATE developed Biograph mMR model is accurate in comparison to the real scanner performance and can be used for evaluating innovative processing methods for applications in clinical PET/MR protocols.

  1. Ella-V and technology usage technology usage in an english language and literacy acquisition validation randomized controlled trial study

    Directory of Open Access Journals (Sweden)

    Roisin P. Corcoran

    2014-12-01

    Full Text Available This paper describes the use of technology to provide virtual professional development (VPD for teachers and to conduct classroom observations in a study of English Language Learner (ELL instruction in grades K–3. The technology applications were part of a cluster randomized control trial (RCT design for a federally funded longitudinal validation study of a particular program, English Language and Literacy Acquisition-Validation, ELLA- V, to determine its degree of impact on English oral language/literacy, reading, and science across 63 randomly assigned urban, suburban, and rural schools (first year of implementation. ELLA-V also examines the impact of bimonthly VPD for treatment teachers compared to comparison group teachers on pedagogical skills, measured by sound observation instruments, and on student achievement, measured by state/national English language/literacy/reading tests and a national science test. This study features extensive technology use via virtual observations, bimonthly VPD, and randomly assigned treatment and control schools with students served in English as second language (ESL instructional time. The study design and methodology are discussed relativeto the specialized uses of technology and issues involving the evaluation of technology’s contribution to the intervention of interest and of the efficient, cost-effective execution of the study.

  2. Dual isotope, single acquisition parathyroid imaging

    International Nuclear Information System (INIS)

    Triantafillou, M.; McDonald, H.J.

    1998-01-01

    Full text: Nuclear Medicine parathyroid imaging using Thallium-201(TI) and Technetium-99m(Tc) is an often used imaging modality for the detection of parathyroid adenomas and hyper parathyroidism. The conventional Tl/Tc subtraction technique requires 2 separate injections and acquisitions which are then normalised and subtracted from each other. This lengthy technique is uncomfortable for patients and can result in false positive scan results due to patient movement between and during the acquisition process. We propose a simplified injection and single acquisition technique, that reduces the chance of movement and thus reduces the chance of false positive scan results. The technique involves the injection of Tc followed by the Tl injection 10 minutes later. After a further 10 min wait, imaging is performed using a dual isotope acquisition, with window (W) 1 set on 140 keV 20%W 5% off peak and W2 peaked for 70 keV 20%W., acquired for 10 minutes. We have imaged 27 patients with this technique, 15 had positive parathyroid imaging. Of the 15, 11 had positive ultrasound correlation. Of the remaining 4, 2 have had positive surgical findings for adenomas, the other 2 are awaiting follow-up. Of the 12 patients with negative parathyroid imaging, 2 have been shown to be false - negative with surgery. In conclusion, the single acquisition technique suggested by us is a valid method of imaging parathyroids that reduces the chance of false positive results due to movement

  3. Programme RAE: software that automates data acquisition in nuclear spectroscopy

    International Nuclear Information System (INIS)

    Bellido, Luis F.

    1995-07-01

    A software for automatic acquisition and storing of nuclear spectra was developed. This program is to be used in a system composed of a radiation detector, a Spectrum-ACE or ADCAM and the Maestro II emulation software. In this paper the operating mode is fully described and several examples are given. (author). 2 refs

  4. Target acquisition: Human observer performance studies and TARGAC model validation (Final Report)

    NARCIS (Netherlands)

    Valeton, J.M.; Bijl, P.; Gillespie, P.

    1995-01-01

    Human target acquisition performance was studied using the thermal imagery that was collected during Battlefield Emissives Sources Trials under the European Theater Weather and Obscurants, (BEST TWO), organized by NATO AC243/Panel4/RSG.l5 in 1990. Recognition and identification probabilities were

  5. Low-level-signal data acquisition for the MFTF superconducting-magnet system

    International Nuclear Information System (INIS)

    Montoya, C.R.

    1981-01-01

    Acquisition of low level signals from sensors mounted on the superconducting yin-yang magnet in the Mirror Fusion Test Facility (MFTF) imposes very strict requirements on the magnet signal conditioning and data acquisition system. Of the various types of sensors required, thermocouples, strain gages, and voltage taps produce very low level outputs. These low level outputs must be accurately measured in the harsh environment of slowly varying magnetic fields, cryogenic temperatures, high vacuum, pulse power and 60 Hz electrical noise, possible neutron radiation, and high common mode voltage resulting from superconducting magnet quench. Successful measurements require careful attention to grounding, shielding, signal handling and processing in the data acquisition system. The magnet instrumentation system provides a means of effectively measuring both low level signals and high level signals from all types of sensors

  6. Liquid chromatography with high resolution mass spectrometry for identification of organic contaminants in fish fillet: screening and quantification assessment using two scan modes for data acquisition.

    Science.gov (United States)

    Munaretto, Juliana S; May, Marília M; Saibt, Nathália; Zanella, Renato

    2016-07-22

    This study proposed a strategy to identify and quantify 182 organic contaminants from different chemical classes, as for instance pesticides, veterinary drug and personal care products, in fish fillet using liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (LC-QToF/MS). For this purpose, two different scan methods (full scan and all ions MS/MS) were evaluated to assess the best option for screening analysis in spiked fish fillet samples. In general, full scan acquisition was found to be more reliable (84%) in the automatic identification and quantification when compared to all ions MS/MS with 72% of the compounds detected. Additionally, a qualitative automatic search showed a mass accuracy error below 5ppm for 77% of the compounds in full scan mode compared to only 52% in all ions MS/MS scan. However, all ions MS/MS provides fragmentation information of the target compounds. Undoubtedly, structural information of a wide number of compounds can be obtained using high resolution mass spectrometry (HRMS), but it is necessary thoroughly assess it, in order to choose the best scan mode. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Modeling and knowledge acquisition processes using case-based inference

    Directory of Open Access Journals (Sweden)

    Ameneh Khadivar

    2017-03-01

    Full Text Available The method of acquisition and presentation of the organizational Process Knowledge has considered by many KM researches. In this research a model for process knowledge acquisition and presentation has been presented by using the approach of Case Base Reasoning. The validation of the presented model was evaluated by conducting an expert panel. Then a software has been developed based on the presented model and implemented in Eghtesad Novin Bank of Iran. In this company, based on the stages of the presented model, first the knowledge intensive processes has been identified, then the Process Knowledge was stored in a knowledge base in the format of problem/solution/consequent .The retrieval of the knowledge was done based on the similarity of the nearest neighbor algorithm. For validating of the implemented system, results of the system has compared by the results of the decision making of the expert of the process.

  8. Information management system breadboard data acquisition and control system.

    Science.gov (United States)

    Mallary, W. E.

    1972-01-01

    Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.

  9. Multi-mode remote participation on the GOLEM tokamak

    International Nuclear Information System (INIS)

    Svoboda, V.; Huang, B.; Mlynar, J.; Pokol, G.I.; Stoeckel, J.; Vondrasek, G.

    2011-01-01

    The GOLEM tokamak (formerly CASTOR) at Czech Technical University is demonstrated as an educational tokamak device for domestic and foreign students. Remote participation of several foreign universities (in Hungary, Belgium, Poland and Costa Rica) has been successfully performed. A unique feature of the GOLEM device is functionality which enables complete remote participation and control, solely through Internet access. Basic remote control is possible either in online mode via WWW/SSH interface or offline mode using batch processing code. Discharge parameters are set in each case to configure the tokamak for a plasma discharge. Using the X11 protocol it is possible to control in an advanced mode many technological aspects of the tokamak operation, including: i) vacuum pump initialization, ii) chamber baking, iii) charging of power supplies, iv) plasma discharge scenario, v) data acquisition system.

  10. DPLL implementation in carrier acquisition and tracking for burst DS-CDMA receivers.

    Science.gov (United States)

    Guan, Yun-feng; Zhang, Zhao-yang; Lai, Li-feng

    2003-01-01

    This paper presents the architectures, algorithms, and implementation considerations of the digital phase locked loop (DPLL) used for burst-mode packet DS-CDMA receivers. As we know, carrier offset is a rather challenging problem in CDMA system. According to different applications, different DPLL forms should be adopted to correct different maximum carrier offset in CDMA systems. One classical DPLL and two novel DPLL forms are discussed in the paper. The acquisition range of carrier offset can be widened by using the two novel DPLL forms without any performance degradation such as longer acquisition time or larger variance of the phase error. The maximum acquisition range is 1/(4T), where T is the symbol period. The design can be implemented by FPGA directly.

  11. Developmental Stages in Receptive Grammar Acquisition: A Processability Theory Account

    Science.gov (United States)

    Buyl, Aafke; Housen, Alex

    2015-01-01

    This study takes a new look at the topic of developmental stages in the second language (L2) acquisition of morphosyntax by analysing receptive learner data, a language mode that has hitherto received very little attention within this strand of research (for a recent and rare study, see Spinner, 2013). Looking at both the receptive and productive…

  12. Proceedings of the workshop on triggering and data acquisition for experiments at the Supercollider

    Energy Technology Data Exchange (ETDEWEB)

    Donaldson, R. [ed.

    1989-04-01

    This meeting covered the following subjects: triggering requirements for SSC physics; CDF level 3 trigger; D0 trigger design; AMY trigger systems; Zeus calorimeter first level trigger; data acquisition for the Zeus Central Tracking Detector; trigger and data acquisition aspects for SSC tracking; data acquisition systems for the SSC; validating triggers in CDF level 3; optical data transmission at SSC; time measurement system at SSC; SSC/BCD data acquisition system; microprocessors and other processors for triggering and filtering at the SSC; data acquisition, event building, and on-line processing; LAA real-time benchmarks; object-oriented system building at SSC; and software and project management. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  13. Respiratory gating of cardiac PET data in list-mode acquisition

    International Nuclear Information System (INIS)

    Livieratos, Lefteris; Rajappan, Kim; Camici, Paolo G.; Stegger, Lars; Schafers, Klaus; Bailey, Dale L.

    2006-01-01

    Respiratory motion has been identified as a source of artefacts in most medical imaging modalities. This paper reports on respiratory gating as a means to eliminate motion-related inaccuracies in PET imaging. Respiratory gating was implemented in list mode with physiological signal recorded every millisecond together with the PET data. Respiration was monitored with an inductive respiration monitor using an elasticised belt around the patient's chest. Simultaneous ECG gating can be maintained independently by encoding ECG trigger signal into the list-mode data. Respiratory gating is performed in an off-line workstation with gating parameters defined retrospectively. The technique was applied on a preliminary set of patient data with C 15 O. Motion was visually observed in the cine displays of the sagittal and coronal views of the reconstructed respiratory gated images. Significant changes in the cranial-caudal position of the heart could be observed. The centroid of the cardiac blood pool showed an excursion of 4.5-16.5 mm (mean 8.5±4.8 mm) in the cranial-caudal direction, with more limited excursion of 1.1-7.0 mm (mean 2.5±2.2 mm) in the horizontal direction and 1.3-3.7 mm (mean 2.4±0.9 mm) in the vertical direction. These preliminary data show that the extent of motion involved in respiration is comparable to myocardial wall thickness, and respiratory gating may be considered in order to reduce this effect in the reconstructed images. (orig.)

  14. Respiratory gating of cardiac PET data in list-mode acquisition.

    Science.gov (United States)

    Livieratos, Lefteris; Rajappan, Kim; Stegger, Lars; Schafers, Klaus; Bailey, Dale L; Camici, Paolo G

    2006-05-01

    Respiratory motion has been identified as a source of artefacts in most medical imaging modalities. This paper reports on respiratory gating as a means to eliminate motion-related inaccuracies in PET imaging. Respiratory gating was implemented in list mode with physiological signal recorded every millisecond together with the PET data. Respiration was monitored with an inductive respiration monitor using an elasticised belt around the patient's chest. Simultaneous ECG gating can be maintained independently by encoding ECG trigger signal into the list-mode data. Respiratory gating is performed in an off-line workstation with gating parameters defined retrospectively. The technique was applied on a preliminary set of patient data with C(15)O. Motion was visually observed in the cine displays of the sagittal and coronal views of the reconstructed respiratory gated images. Significant changes in the cranial-caudal position of the heart could be observed. The centroid of the cardiac blood pool showed an excursion of 4.5-16.5 mm (mean 8.5+/-4.8 mm) in the cranial-caudal direction, with more limited excursion of 1.1-7.0 mm (mean 2.5+/-2.2 mm) in the horizontal direction and 1.3-3.7 mm (mean 2.4+/-0.9 mm) in the vertical direction. These preliminary data show that the extent of motion involved in respiration is comparable to myocardial wall thickness, and respiratory gating may be considered in order to reduce this effect in the reconstructed images.

  15. Experience from Tore Supra acquisition system and evolutions

    International Nuclear Information System (INIS)

    Guillerminet, B.; Buravand, Y.; Chatelier, E.; Leroux, F.

    2004-01-01

    The Tore Supra tokamak has been upgraded to explore long duration plasma discharges up to 1000s. Since summer 2001, the acquisition system operates in continuous mode apart of the data processing which is still done after the pulse. In the first part, we explore a few solutions to process continuously the data during the pulse, based on parallel processing on a Linux farm and then on a CONDOR system. The second part is devoted to the Web service exposing the Tore Supra operation. In the last part, the VME acquisition system has been redesigned to keep up with the high data rates required by a few diagnostics. The workflow is now distributed among a few computers. At the end, we give the current status of the realisation and the future planning

  16. Data acquisition card for fluctuation correlation spectroscopy allowing full access to the detected photon sequence

    OpenAIRE

    Eid, JS; Muller, JD; Gratton, E

    2000-01-01

    Typically, fluctuation correlation spectroscopy (FCS) data acquisition cards measure the number of photon events per time interval (i.e., bin) - time mode. Commercial FCS cards combine the bins through hardware in order to calculate the autocorrelation function. Such a design therefore does not yield the time resolved photon sequence, but only the autocorrelation of that sequence. A different acquisition method which measures the number of time intervals between photon events has been impleme...

  17. On normal modes of gas sheets and discs

    International Nuclear Information System (INIS)

    Drury, L.O'C.

    1980-01-01

    A method is described for calculating the reflection and transmission coefficients characterizing normal modes of the Goldreich-Lynden-Bell gas sheet. Two families of gas discs without self-gravity for which the normal modes can be found analytically are given and used to illustrate the validity of the sheet approximation. (author)

  18. The Attitude Determination Scale for Value Acquisition: A Validity and Reliability Study

    Science.gov (United States)

    Cetin, Saban

    2017-01-01

    This study aims to develop a measurement tool having measurement reliability with the aim of determining attitudes for values acquisition of secondary school students. The study was conducted on totally 325 high school senior students as 200 female and 125 male students in spring semester of 2014-2015 educational year. In the study, expert opinion…

  19. Photovoltaic module parameters acquisition model

    Energy Technology Data Exchange (ETDEWEB)

    Cibira, Gabriel, E-mail: cibira@lm.uniza.sk; Koščová, Marcela, E-mail: mkoscova@lm.uniza.sk

    2014-09-01

    Highlights: • Photovoltaic five-parameter model is proposed using Matlab{sup ®} and Simulink. • The model acquisits input sparse data matrix from stigmatic measurement. • Computer simulations lead to continuous I–V and P–V characteristics. • Extrapolated I–V and P–V characteristics are in hand. • The model allows us to predict photovoltaics exploitation in different conditions. - Abstract: This paper presents basic procedures for photovoltaic (PV) module parameters acquisition using MATLAB and Simulink modelling. In first step, MATLAB and Simulink theoretical model are set to calculate I–V and P–V characteristics for PV module based on equivalent electrical circuit. Then, limited I–V data string is obtained from examined PV module using standard measurement equipment at standard irradiation and temperature conditions and stated into MATLAB data matrix as a reference model. Next, the theoretical model is optimized to keep-up with the reference model and to learn its basic parameters relations, over sparse data matrix. Finally, PV module parameters are deliverable for acquisition at different realistic irradiation, temperature conditions as well as series resistance. Besides of output power characteristics and efficiency calculation for PV module or system, proposed model validates computing statistical deviation compared to reference model.

  20. Photovoltaic module parameters acquisition model

    International Nuclear Information System (INIS)

    Cibira, Gabriel; Koščová, Marcela

    2014-01-01

    Highlights: • Photovoltaic five-parameter model is proposed using Matlab ® and Simulink. • The model acquisits input sparse data matrix from stigmatic measurement. • Computer simulations lead to continuous I–V and P–V characteristics. • Extrapolated I–V and P–V characteristics are in hand. • The model allows us to predict photovoltaics exploitation in different conditions. - Abstract: This paper presents basic procedures for photovoltaic (PV) module parameters acquisition using MATLAB and Simulink modelling. In first step, MATLAB and Simulink theoretical model are set to calculate I–V and P–V characteristics for PV module based on equivalent electrical circuit. Then, limited I–V data string is obtained from examined PV module using standard measurement equipment at standard irradiation and temperature conditions and stated into MATLAB data matrix as a reference model. Next, the theoretical model is optimized to keep-up with the reference model and to learn its basic parameters relations, over sparse data matrix. Finally, PV module parameters are deliverable for acquisition at different realistic irradiation, temperature conditions as well as series resistance. Besides of output power characteristics and efficiency calculation for PV module or system, proposed model validates computing statistical deviation compared to reference model

  1. SALTICAM: $0.5M acquisition camera: every big telescope should have one

    Science.gov (United States)

    O'Donoghue, Darragh; Bauermeister, Etienne; Carter, David B.; Evans, Geoffrey P.; Koorts, Willie P.; O'Connor, James; Osman, Faranah; van der Merwe, Stan; Bigelow, Bruce C.

    2003-03-01

    The Southern African Large Telescope (SALT) is a 10-m class telescope presently under construction at Sutherland in South Africa. It is designed along the lines of the Hobby-Eberly Telescope (HET) at McDonald Observatory in West Texas. SALTICAM will be the Acquisition Camera and simple Science Imager (ACSI) for this telescope. It will also function as the Verification Instrument (VI) to check the performance of the telescope during commissioning. In VI mode, SALTICAM will comprise a filter unit, shutter and cryostat with a 2x1 mosaic of 2k x 4k x 15 micron pixel CCDs. It will be mounted at the f/4.2 corrected prime focus of the telescope. In ACSI mode it will be fed by a folding flat located close to the exit pupil of the telescope. ACSI mode will have the same functional components as VI mode but it will in addition be garnished with focal conversion lenses to re-image the corrected prime focal plane at f/2. The lenses will be made from UV transmitting crystals as the wavelength range for which the instrument is designed will span 320 to 950 nm. In addition to acting as Verification Instrument and Acquisition Camera, SALTICAM will perform simple science imaging in support of other instruments, but will also have a high time resolution capability which is not widely available on large telescopes. This paper will describe the design of the instrument, emphasizing features of particular interest.

  2. Development and Validation of Shipboard Noise Exposure Data Acquisition Procedures.

    Science.gov (United States)

    1981-11-05

    ational modes, etc. 2) Analytic Models. The analytic models are represented by the mathematical and statistical relationships used to analyze the...INFORMATION CODE OPERATING CONDITIONS Ship’s Class FF1052 KNOX Readiness (D .Cond. 10 Conid. 1110 Space Surveyed Aux. Rm. *1, Upper Lvel Cond. IV[]Cond. VO

  3. How to improve the validity of sexual behaviour reporting: systematic review of questionnaire delivery modes in developing countries.

    Science.gov (United States)

    Langhaug, Lisa F; Sherr, Lorraine; Cowan, Frances M

    2010-03-01

    To systematically review comparative research from developing countries on the effects of questionnaire delivery mode. We searched Medline, EMbase and PsychINFO and ISSTDR conference proceedings. Randomized control trials and quasi-experimental studies were included if they compared two or more questionnaire delivery modes, were conducted in a developing country, reported on sexual behaviours and occurred after 1980. A total of 28 articles reporting on 26 studies met the inclusion criteria. Heterogeneity of reported trial outcomes between studies made it inappropriate to combine trial outcomes. Eighteen studies compared audio computer-assisted survey instruments (ACASI) or its derivatives [personal digital assistant (PDA) or computer-assisted personal interview (CAPI)] against another self-administered questionnaires, face-to-face interviews or random response technique. Despite wide variation in geography and populations sampled, there was strong evidence that computer-assisted interviews lowered item-response rates and raised rates of reporting sensitive behaviours. ACASI also improved data entry quality. A wide range of sexual behaviours were reported including vaginal, oral, anal and/or forced sex, age of sexual debut, condom use at first and/or last sex. Validation of self-reports using biomarkers was rare. These data reaffirm that questionnaire delivery modes do affect self-reported sexual behaviours and that use of ACASI can significantly reduce reporting bias. Its acceptability and feasibility in developing country settings should encourage researchers to consider its use when conducting sexual health research. Triangulation of self-reported data using biomarkers is recommended. Standardizing sexual behaviour measures would allow for meta-analysis.

  4. An intelligent data acquisition system for fluid mechanics research

    Science.gov (United States)

    Cantwell, E. R.; Zilliac, G.; Fukunishi, Y.

    1989-01-01

    This paper describes a novel data acquisition system for use with wind-tunnel probe-based measurements, which incorporates a degree of specific fluid dynamics knowledge into a simple expert system-like control program. The concept was developed with a rudimentary expert system coupled to a probe positioning mechanism operating in a small-scale research wind tunnel. The software consisted of two basic elements, a general-purpose data acquisition system and the rulebased control element to take and analyze data and supplying decisions as to where to measure, how many data points to take, and when to stop. The system was validated in an experiment involving a vortical flow field, showing that it was possible to increase the resolution of the experiment or, alternatively, reduce the total number of data points required, to achieve parity with the results of most conventional data acquisition approaches.

  5. COLDEX New Data Acquisition Framework

    CERN Document Server

    Grech, Christian

    2015-01-01

    COLDEX (COLD bore EXperiment) is an experiment of the TE-VSC group installed in the Super Proton Synchrotron (SPS) which mimics a LHC type cryogenic vacuum system. In the framework of the High Luminosity upgrade of the LHC (HL-LHC project), COLDEX has been recommissioned in 2014 in order to validate carbon coatings performances at cryogenic temperature with LHC type beams. To achieve this mission, a data acquisition system is needed to retrieve and store information from the different experiment’s systems (vacuum, cryogenics, controls, safety) and perform specific calculations. This work aimed to completely redesign, implement, test and operate a brand new data acquisition framework based on communication with the experiment’s PLCs for the devices potentially available over network. The communication protocol to the PLCs is based on data retrieval both from CERN middleware infrastructures (CMW, JAPC) and on a novel open source Simatic S7 data exchange package over TCP/IP (libnodave).

  6. An open-source, FireWire camera-based, Labview-controlled image acquisition system for automated, dynamic pupillometry and blink detection.

    Science.gov (United States)

    de Souza, John Kennedy Schettino; Pinto, Marcos Antonio da Silva; Vieira, Pedro Gabrielle; Baron, Jerome; Tierra-Criollo, Carlos Julio

    2013-12-01

    The dynamic, accurate measurement of pupil size is extremely valuable for studying a large number of neuronal functions and dysfunctions. Despite tremendous and well-documented progress in image processing techniques for estimating pupil parameters, comparatively little work has been reported on practical hardware issues involved in designing image acquisition systems for pupil analysis. Here, we describe and validate the basic features of such a system which is based on a relatively compact, off-the-shelf, low-cost FireWire digital camera. We successfully implemented two configurable modes of video record: a continuous mode and an event-triggered mode. The interoperability of the whole system is guaranteed by a set of modular software components hosted on a personal computer and written in Labview. An offline analysis suite of image processing algorithms for automatically estimating pupillary and eyelid parameters were assessed using data obtained in human subjects. Our benchmark results show that such measurements can be done in a temporally precise way at a sampling frequency of up to 120 Hz and with an estimated maximum spatial resolution of 0.03 mm. Our software is made available free of charge to the scientific community, allowing end users to either use the software as is or modify it to suit their own needs. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Continuous and real-time data acquisition system for superconducting tokamaks HT-7 and TRIAM-1M

    International Nuclear Information System (INIS)

    Wang, F.; Luo, J.R.; Nakamura, K.; Sato, K.N.; Hanada, K.; Sakamoto, M.; Idei, H.; Kawasaki, S.; Nakashima, H.

    2006-01-01

    Conventional data acquisition systems cannot deal with data acquisition for a long-time discharge of a nuclear fusion reactor. Thus, continuous data acquisition with a real-time data presentation during discharge must be developed. Two data acquisition systems, which include alternating CAMAC data acquisition and long-time PCI data acquisition, are designed for the long-time operation of HT-7 tokamak. Since an effective alternating mode is adopted, the alternating CAMAC data acquisition can accurately and continuously acquire data at a rate of 10 kHz. The acquired data is immediately transmitted to a data server and real-time results can be presented during the plasma discharge. As for the long-time PCI data acquisition, a special kind of PCI A/D card, which has a hard disk on board, is designed to collect data at a max speed of 200 kHz. Thus, the total sampling duration is only related to the capacity of the hard disk on board. These two types of data acquisitions were applied to HT-7 tokamak and a 250 s discharge was acquired. These data acquisition systems were also successfully demonstrated on a 2500 s plasma discharge on TRIAM-1M. This paper describes the two data acquisitions in detail

  8. Partial Acquistion as an Entry Mode in Transition Economies

    DEFF Research Database (Denmark)

    Jakobsen, Kristian; Meyer, Klaus E.

    2007-01-01

    Multinational enterprises often acquire stakes in an existing enterprise when entering emerging economies. This paper examines the determinants of entry mode choices with a special focus on these partial acquisitions, which have received little attention in the scholarly literature. We show...... negotiations are subject to significant stakeholder interference. (For more information, please contact: Kristian Jakobsen, Copenhagen Business School, Denmark: kj.int@cbs.dk)...

  9. A data acquisition system for measuring ionization cross section in laser multi-step resonant ionization experiment

    International Nuclear Information System (INIS)

    Qian Dongbin; Guo Yuhui; Zhang Dacheng; Chinese Academy of Sciences, Beijing; Ma Xinwen; Zhao Zhizheng; Wang Yanyu; Zu Kailing

    2006-01-01

    A CAMAC data acquisition system for measuring ionization cross section in laser multi-step resonant ionization experiment is described. The number of scalers in the front-end CAMAC can be adjusted by changing the data read-out table files. Both continuous and manual acquisition models are available, and there is a wide adjustable range from 1 ms to 800 s with the acquisition time unit. The long-term stability, Δt/t, for the data acquisition system with an acquisition time unit of 100 s was measured to be better than ±0.01%, thus validating its reliability in long-term online experimental data acquisition. The time response curves for three electrothermal power-meters were also measured by this DAQ system. (authors)

  10. Biosignal integrated circuit with simultaneous acquisition of ECG and PPG for wearable healthcare applications.

    Science.gov (United States)

    Kim, Hyungseup; Park, Yunjong; Ko, Youngwoon; Mun, Yeongjin; Lee, Sangmin; Ko, Hyoungho

    2018-01-01

    Wearable healthcare systems require measurements from electrocardiograms (ECGs) and photoplethysmograms (PPGs), and the blood pressure of the user. The pulse transit time (PTT) can be calculated by measuring the ECG and PPG simultaneously. Continuous-time blood pressure without using an air cuff can be estimated by using the PTT. This paper presents a biosignal acquisition integrated circuit (IC) that can simultaneously measure the ECG and PPG for wearable healthcare applications. Included in this biosignal acquisition circuit are a voltage mode instrumentation amplifier (IA) for ECG acquisition and a current mode transimpedance amplifier for PPG acquisition. The analog outputs from the ECG and PPG channels are muxed and converted to digital signals using 12-bit successive approximation register (SAR) analog-to-digital converter (ADC). The proposed IC is fabricated by using a standard 0.18 μm CMOS process with an active area of 14.44 mm2. The total current consumption for the multichannel IC is 327 μA with a 3.3 V supply. The measured input referred noise of ECG readout channel is 1.3 μVRMS with a bandwidth of 0.5 Hz to 100 Hz. And the measured input referred current noise of the PPG readout channel is 0.122 nA/√Hz with a bandwidth of 0.5 Hz to 100 Hz. The proposed IC, which is implemented using various circuit techniques, can measure ECG and PPG signals simultaneously to calculate the PTT for wearable healthcare applications.

  11. The design of the Hyperon Data Acquisition System

    International Nuclear Information System (INIS)

    Gee, C.N.P.

    1980-12-01

    A new Native-mode Data Acquisition system, running on a VAX 11/780, has been designed for the SPS Hyperon Experiments at CERN. The system incorporates a variable number of communicating processes running under VAX/VMS, including user-written monitoring processes. Event handling has been implemented into the CAMAC Driver, and facilities are provided for using a data buffer much larger than the System Maximum Working-set Size. A generalised debugging facility for non terminal-oriented processes is also supported. (author)

  12. Task Performance with List-Mode Data

    Science.gov (United States)

    Caucci, Luca

    This dissertation investigates the application of list-mode data to detection, estimation, and image reconstruction problems, with an emphasis on emission tomography in medical imaging. We begin by introducing a theoretical framework for list-mode data and we use it to define two observers that operate on list-mode data. These observers are applied to the problem of detecting a signal (known in shape and location) buried in a random lumpy background. We then consider maximum-likelihood methods for the estimation of numerical parameters from list-mode data, and we characterize the performance of these estimators via the so-called Fisher information matrix. Reconstruction from PET list-mode data is then considered. In a process we called "double maximum-likelihood" reconstruction, we consider a simple PET imaging system and we use maximum-likelihood methods to first estimate a parameter vector for each pair of gamma-ray photons that is detected by the hardware. The collection of these parameter vectors forms a list, which is then fed to another maximum-likelihood algorithm for volumetric reconstruction over a grid of voxels. Efficient parallel implementation of the algorithms discussed above is then presented. In this work, we take advantage of two low-cost, mass-produced computing platforms that have recently appeared on the market, and we provide some details on implementing our algorithms on these devices. We conclude this dissertation work by elaborating on a possible application of list-mode data to X-ray digital mammography. We argue that today's CMOS detectors and computing platforms have become fast enough to make X-ray digital mammography list-mode data acquisition and processing feasible.

  13. Burst Mode ASIC-Based Modem

    Science.gov (United States)

    1997-01-01

    The NASA Lewis Research Center is sponsoring the Advanced Communication Technology Insertion (ACTION) for Commercial Space Applications program. The goal of the program is to expedite the development of new technology with a clear path towards productization and enhancing the competitiveness of U.S. manufacturers. The industry has made significant investment in developing ASIC-based modem technology for continuous-mode applications and has made investigations into East, reliable acquisition of burst-mode digital communication signals. With rapid advances in analog and digital communications ICs, it is expected that more functions will be integrated onto these parts in the near future. In addition custom ASIC's can also be developed to address the areas not covered by the other IC's. Using the commercial chips and custom ASIC's, lower-cost, compact, reliable, and high-performance modems can be built for demanding satellite communication application. This report outlines a frequency-hop burst modem design based on commercially available chips.

  14. Optimizing the data acquisition rate for a remotely controllable structural monitoring system with parallel operation and self-adaptive sampling

    International Nuclear Information System (INIS)

    Sheng, Wenjuan; Guo, Aihuang; Liu, Yang; Azmi, Asrul Izam; Peng, Gang-Ding

    2011-01-01

    We present a novel technique that optimizes the real-time remote monitoring and control of dispersed civil infrastructures. The monitoring system is based on fiber Bragg gating (FBG) sensors, and transfers data via Ethernet. This technique combines parallel operation and self-adaptive sampling to increase the data acquisition rate in remote controllable structural monitoring systems. The compact parallel operation mode is highly efficient at achieving the highest possible data acquisition rate for the FBG sensor based local data acquisition system. Self-adaptive sampling is introduced to continuously coordinate local acquisition and remote control for data acquisition rate optimization. Key issues which impact the operation of the whole system, such as the real-time data acquisition rate, data processing capability, and buffer usage, are investigated. The results show that, by introducing parallel operation and self-adaptive sampling, the data acquisition rate can be increased by several times without affecting the system operating performance on both local data acquisition and remote process control

  15. A data acquisition system based on general VME system in WinXP

    International Nuclear Information System (INIS)

    Ning Zhe; Qian Sen; Wang Yifang; Heng Yuekun; Zhang Jiawei; Fu Zaiwei; Qi Ming; Zheng Yangheng

    2010-01-01

    The compilation and encapsulation of a general data acquisition system based on VME board in WinXP environment was developed using LabVIEW with graphics interface. By integrating the emulational instrument panel of LabVIEW and calling the Dynamic Link Libraries (DLLs) of crate controller, the VME modules were encapsulated into function modules independently, for convenience of use. The BLT, MBLT and CBLT readout modes for different VME boards were studied. The modules can be selected and modified easily according to the requirements of different tests. Finally, successful applications of the high resolution data acquisition software (DAQ) in several experiment environments are reported.(authors)

  16. A beamline design and data acquisition with the 20-MeV, 20-ps electron beam for the higher-order mode studies of the APS SR-rf cavities

    International Nuclear Information System (INIS)

    Song, J.; Nassiri, A.; Daly, R.

    1993-01-01

    A beamline has been designed and assembled to use the ANL Chemistry Division 20-MeV electron linac for the testing of higher-order mode excitation and damping in rf cavities. The beamline consists of two sections (a beam collimating section with a 1.5 inches-OD vacuum line, and a cavity test section with a 3 inches-OD vacuum line), separated by two double aluminum foil windows. The beam diagnostics consist of a stripline beam position monitor, integrating current transformers, fluorescent screens, and a Faraday cup. EPICS (Experimental Physics and Industrial Control System) is used for beamline control, monitoring, and data acquisition. Also described is the diagnostic system used for beam image capture and analysis using EPICS-controlled hardware and PV-WAVE software. The rf cavity measurement will be described in a separate paper

  17. Amplification of magnetic modes in laser-created plasmas

    International Nuclear Information System (INIS)

    Matte, J.P.; Bendib, A.; Luciani, J.F.

    1987-01-01

    The amplification of magnetic (Weibel) modes in laser-plasma interaction is investigated by use of unperturbed distribution functions given by Fokker-Planck simulations and a dispersion relation valid for all collisionality regimes. In the five cases studied, a strongly growing mode is found in the underdense plasma, where v-bar/sub x/ 2 2 , and the usual slowly growing one in the overdense plasma. The first mode grows convectively outwards by more than 10 4 . The convection velocities are found to be very different from Nernst values

  18. Hi-Res scan mode in clinical MDCT systems: Experimental assessment of spatial resolution performance.

    Science.gov (United States)

    Cruz-Bastida, Juan P; Gomez-Cardona, Daniel; Li, Ke; Sun, Heyi; Hsieh, Jiang; Szczykutowicz, Timothy P; Chen, Guang-Hong

    2016-05-01

    The introduction of a High-Resolution (Hi-Res) scan mode and another associated option that combines Hi-Res mode with the so-called High Definition (HD) reconstruction kernels (referred to as a Hi-Res/HD mode in this paper) in some multi-detector CT (MDCT) systems offers new opportunities to increase spatial resolution for some clinical applications that demand high spatial resolution. The purpose of this work was to quantify the in-plane spatial resolution along both the radial direction and tangential direction for the Hi-Res and Hi-Res/HD scan modes at different off-center positions. A technique was introduced and validated to address the signal saturation problem encountered in the attempt to quantify spatial resolution for the Hi-Res and Hi-Res/HD scan modes. Using the proposed method, the modulation transfer functions (MTFs) of a 64-slice MDCT system (Discovery CT750 HD, GE Healthcare) equipped with both Hi-Res and Hi-Res/HD modes were measured using a metal bead at nine different off-centered positions (0-16 cm with a step size of 2 cm); at each position, both conventional scans and Hi-Res scans were performed. For each type of scan and position, 80 repeated acquisitions were performed to reduce noise induced uncertainties in the MTF measurements. A total of 15 reconstruction kernels, including eight conventional kernels and seven HD kernels, were used to reconstruct CT images of the bead. An ex vivo animal study consisting of a bone fracture model was performed to corroborate the MTF results, as the detection of this high-contrast and high frequency task is predominantly determined by spatial resolution. Images of this animal model generated by different scan modes and reconstruction kernels were qualitatively compared with the MTF results. At the centered position, the use of Hi-Res mode resulted in a slight improvement in the MTF; each HD kernel generated higher spatial resolution than its counterpart conventional kernel. However, the MTF along the

  19. Component mode synthesis in structural dynamics

    International Nuclear Information System (INIS)

    Reddy, G.R.; Vaze, K.K.; Kushwaha, H.S.

    1993-01-01

    In seismic analysis of Nuclear Reactor Structures and equipments eigen solution requires large computer time. Component mode synthesis is an efficient technique with which one can evaluate dynamic characteristics of a large structure with minimum computer time. Due to this reason it is possible to do a coupled analysis of structure and equipment which takes into account the interaction effects. Basically in this the method large size structure is divided into small substructures and dynamic characteristics of individual substructure are determined. The dynamic characteristics of entire structure are evaluated by synthesising the individual substructure characteristics. Component mode synthesis has been applied in this paper to the analysis of a tall heavy water upgrading tower. Use of fixed interface normal modes, constrained modes, attachment modes in the component mode synthesis using energy principle and using Ritz vectors have been discussed. The validity of this method is established by solving fixed-fixed beam and comparing the results obtained by conventional and classical method. The eigen value problem has been solved using simultaneous iteration method. (author)

  20. Development of a prototype acquisition and data processing system based on FPGA

    International Nuclear Information System (INIS)

    Romero, L; Bellino, P

    2012-01-01

    We present the first stage of the expansion and improvement of a signal acquisition system based on FPGA. This system will acquire and process signals from nuclear detectors working in both pulse and current mode. The aim of this development is to unify all the actual systems for physical measurements in nuclear facilities and reactors (author)

  1. Raman intensity and vibrational modes of armchair CNTs

    Science.gov (United States)

    Hur, Jaewoong; Stuart, Steven J.

    2017-07-01

    Raman intensity changes and frequency patterns have been studied using the various armchair (n, n) to understand the variations of bond polarizability, in regard to changing diameters, lengths, and the number of atoms in the (n, n). The Raman intensity trends of the (n, n) are validated by those of Cn isomers. For frequency trends, similar frequency patterns and frequency inward shifts for the (n, n) are characterized. Also, VDOS trends of the (n, n) expressing Raman modes are interpreted. The decomposition of vibrational modes in the (n, n) into radial, longitudinal, and tangential mode is beneficially used to recognize the distinct characteristics of vibrational modes.

  2. A Further Comparison of Manual Signing, Picture Exchange, and Speech-Generating Devices as Communication Modes for Children with Autism Spectrum Disorders

    Science.gov (United States)

    van der Meer, Larah; Sutherland, Dean; O'Reilly, Mark F.; Lancioni, Giulio E.; Sigafoos, Jeff

    2012-01-01

    We compared acquisition of, and preference for, manual signing (MS), picture exchange (PE), and speech-generating devices (SGDs) in four children with autism spectrum disorders (ASD). Intervention was introduced across participants in a non-concurrent multiple-baseline design and acquisition of the three communication modes was compared in an…

  3. Validation of a pulsed electric field process to pasteurize strawberry puree

    Science.gov (United States)

    An inexpensive data acquisition method was developed to validate the exact number and shape of the pulses applied during pulsed electric fields (PEF) processing. The novel validation method was evaluated in conjunction with developing a pasteurization PEF process for strawberry puree. Both buffered...

  4. Quasinormal-Mode Expansion of the Scattering Matrix

    Directory of Open Access Journals (Sweden)

    Filippo Alpeggiani

    2017-06-01

    Full Text Available It is well known that the quasinormal modes (or resonant states of photonic structures can be associated with the poles of the scattering matrix of the system in the complex-frequency plane. In this work, the inverse problem, i.e., the reconstruction of the scattering matrix from the knowledge of the quasinormal modes, is addressed. We develop a general and scalable quasinormal-mode expansion of the scattering matrix, requiring only the complex eigenfrequencies and the far-field properties of the eigenmodes. The theory is validated by applying it to illustrative nanophotonic systems with multiple overlapping electromagnetic modes. The examples demonstrate that our theory provides an accurate first-principles prediction of the scattering properties, without the need for postulating ad hoc nonresonant channels.

  5. Improvement of Sidestream Dark Field Imaging with an Image Acquisition Stabilizer

    NARCIS (Netherlands)

    Balestra, Gianmarco M.; Bezemer, Rick; Boerma, E. Christiaan; Yong, Ze-Yie; Sjauw, Krishan D.; Engstrom, Annemarie E.; Koopmans, Matty; Ince, Can

    2010-01-01

    ABSTRACT: BACKGROUND: In the present study we developed, evaluated in volunteers, and clinically validated an image acquisition stabilizer (IAS) for Sidestream Dark Field (SDF) imaging. METHODS: The IAS is a stainless steel sterilizable ring which fits around the SDF probe tip. The IAS creates

  6. Improvement of Sidestream Dark Field Imaging with an Image Acquisition Stabilizer

    NARCIS (Netherlands)

    G. Balestra (Gianmarco); R. Bezemer (Rick); E.C. Boerma (Christiaan); Z-Y. Yong (Ze-Yie); K.D. Sjauw (Krishan); A.E. Engstrom (Annemarie); M. Koopmans (Matty); C. Ince (Can)

    2010-01-01

    textabstractBackground: In the present study we developed, evaluated in volunteers, and clinically validated an image acquisition stabilizer (IAS) for Sidestream Dark Field (SDF) imaging.Methods: The IAS is a stainless steel sterilizable ring which fits around the SDF probe tip. The IAS creates

  7. A graphics subsystem retrofit design for the bladed-disk data acquisition system. M.S. Thesis

    Science.gov (United States)

    Carney, R. R.

    1983-01-01

    A graphics subsystem retrofit design for the turbojet blade vibration data acquisition system is presented. The graphics subsystem will operate in two modes permitting the system operator to view blade vibrations on an oscilloscope type of display. The first mode is a real-time mode that displays only gross blade characteristics, such as maximum deflections and standing waves. This mode is used to aid the operator in determining when to collect detailed blade vibration data. The second mode of operation is a post-processing mode that will animate the actual blade vibrations using the detailed data collected on an earlier data collection run. The operator can vary the rate of payback to view differring characteristics of blade vibrations. The heart of the graphics subsystem is a modified version of AMD's ""super sixteen'' computer, called the graphics preprocessor computer (GPC). This computer is based on AMD's 2900 series of bit-slice components.

  8. Application of new pre-isolation techniques to mode cleaner design

    Energy Technology Data Exchange (ETDEWEB)

    Barriga, Pablo [School of Physics, University of Western Australia, Crawley, WA 6009 (Australia); Woolley, Andrew [School of Physics, University of Western Australia, Crawley, WA 6009 (Australia); Zhao Chunnong [Computer and Information Science, Edith Cowan University, Mount Lawley, WA 6050 (Australia); Blair, David G [School of Physics, University of Western Australia, Crawley, WA 6009 (Australia)

    2004-03-07

    Two very low frequency pre-isolation stages can greatly reduce the residual motion of suspended optical components. In a mode cleaner this can reduce the control forces required on the mirrors, simplifying lock acquisition and reducing noise injection through control forces. This paper describes a 12 m triangular suspended mode cleaner under construction for the AIGO high optical power interferometer. A novel and very compact multistage isolator supports the cavity mirrors. It combines an inverse pendulum in series with a low-mass Roberts linkage, both with pendulum frequencies below 0.1 Hz. The suspension chain is connected to the Roberts linkage via a Euler spring stage and a cantilever spring assembly for vertical isolation. We present an analysis of the mode cleaner, emphasizing the advantage of the improved mode-cleaner suspension and its power-handling capability. The effect of seismic noise on the residual velocity of the mirrors and the predicted frequency stability of the optical cavity are presented.

  9. Application of new pre-isolation techniques to mode cleaner design

    International Nuclear Information System (INIS)

    Barriga, Pablo; Woolley, Andrew; Zhao Chunnong; Blair, David G

    2004-01-01

    Two very low frequency pre-isolation stages can greatly reduce the residual motion of suspended optical components. In a mode cleaner this can reduce the control forces required on the mirrors, simplifying lock acquisition and reducing noise injection through control forces. This paper describes a 12 m triangular suspended mode cleaner under construction for the AIGO high optical power interferometer. A novel and very compact multistage isolator supports the cavity mirrors. It combines an inverse pendulum in series with a low-mass Roberts linkage, both with pendulum frequencies below 0.1 Hz. The suspension chain is connected to the Roberts linkage via a Euler spring stage and a cantilever spring assembly for vertical isolation. We present an analysis of the mode cleaner, emphasizing the advantage of the improved mode-cleaner suspension and its power-handling capability. The effect of seismic noise on the residual velocity of the mirrors and the predicted frequency stability of the optical cavity are presented

  10. Full-field wrist pulse signal acquisition and analysis by 3D Digital Image Correlation

    Science.gov (United States)

    Xue, Yuan; Su, Yong; Zhang, Chi; Xu, Xiaohai; Gao, Zeren; Wu, Shangquan; Zhang, Qingchuan; Wu, Xiaoping

    2017-11-01

    Pulse diagnosis is an essential part in four basic diagnostic methods (inspection, listening, inquiring and palpation) in traditional Chinese medicine, which depends on longtime training and rich experience, so computerized pulse acquisition has been proposed and studied to ensure the objectivity. To imitate the process that doctors using three fingertips with different pressures to feel fluctuations in certain areas containing three acupoints, we established a five dimensional pulse signal acquisition system adopting a non-contacting optical metrology method, 3D digital image correlation, to record the full-field displacements of skin fluctuations under different pressures. The system realizes real-time full-field vibration mode observation with 10 FPS. The maximum sample frequency is 472 Hz for detailed post-processing. After acquisition, the signals are analyzed according to the amplitude, pressure, and pulse wave velocity. The proposed system provides a novel optical approach for digitalizing pulse diagnosis and massive pulse signal data acquisition for various types of patients.

  11. Pricing decisions from experience: the roles of information-acquisition and response modes.

    Science.gov (United States)

    Golan, Hagai; Ert, Eyal

    2015-03-01

    While pricing decisions that are based on experience are quite common, e.g., setting a selling price for a used car, this type of decision has been surprisingly overlooked in psychology and decision research. Previous studies have focused on either choice decisions from experience, or pricing decisions from description. Those studies revealed that pricing involves cognitive mechanisms other than choice, while experience-based decisions involve mechanisms that differ from description-based ones. Thus, the mutual effect of pricing and experience on decision-making remains unclear. To test this effect, we experimentally compared real-money pricing decisions from experience with those from description, and with choices from experience. The results show that the mode of acquiring information affects pricing: the tendency to underprice high-probability prospects and overprice low-probability ones is diminished when pricing is based on experience rather than description. The findings further reveal attenuation of the tendency to underweight rare events, which underlies choices from experience, in pricing decisions from experience. The difference occurs because the response mode affects the search effort and decision strategy in decisions from experience. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Reduction of radiation exposure in PET examinations by data acquisition in the 3D mode; Reduktion der Strahlenexposition bei PET-Untersuchungen durch Datenakquisition im 3D-Modus

    Energy Technology Data Exchange (ETDEWEB)

    Brix, G. [Bundesamt fuer Strahlenschutz, Neuherberg (Germany). Inst. fuer Strahlenhygiene]|[Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie; Adam, L.E. [Department of Radiology, Philadelphia, PA (United States). Div. of Nuclear Medicine; Zaers, J.; Trojan, H.; Doll, J. [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie; Bellemann, M.E. [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie]|[Fachhochschule Jena (Germany). Fachbereich Medizintechnik; Nosske, D. [Bundesamt fuer Strahlenschutz, Neuherberg (Germany). Inst. fuer Strahlenhygiene

    1999-04-01

    Aim: Modern volume PET systems offer the possibility to measure without the shadowing effect of interplane septa (2D mode) and thus to detect coincident events between detectors on distant rings (3D mode). It was the aim of the present paper to characterize the count rate behaviour of a latest-generation whole-body PET system in the 2D and 3D mode as well as to discuss the consequences for the radiation hygiene of PET examinations with 2-[F-18]-fluoro-2-deoxyglucose (18-F-FDG). Methods: All experiments were performed with the PET system ECAT EXACT HR{sup +}. For 2D data acquisition, a collimator of thin tungsten septa was positioned in the field-of-view. The count rate behaviour of the scanner was evaluated in the 2D and 3D mode over a wide range of F-18 activity concentrations following the NEMA protocol. Moreover, PET images of the EEC whole-body phantom with different inserts were acquired in the 2D and 3D mode over a period of 15 min each. For the 3D measurement, the activity concentrations of the F-18 solution were only half of those used for the 2D measurement. Results: For the circular NEMA phantom (diameter=19.4 cm, length=19,0 cm), we observed an increase of the system sensitivity in the 3D mode by a factor of about 5 with respect to the 2D mode (27.7 vs. 5.7 cps/Bq/ml). The evaluation of the activity distributions of the EEC phantom reconstructed from the 3D data set revealed a superior image quality compared to the corresponding 2D images despite the fact that the activity concentrations were only half as high. Conclusion: By using the 3D data acquisition mode, it is possible to markedly reduce the amount of activity to be applied to the patient and nevertheless to improve image quality. In our experience, it is sufficient to administer an activity of 150-200 MBq for whole-body examinations with F-18-FDG, which results in an effective equivalent dose of 3 or 4 mSv, respectively. (orig.) [Deutsch] Ziel: Moderne Volumen-PET-Systeme bieten die Moeglichkeit

  13. Speed in Acquisitions

    DEFF Research Database (Denmark)

    Meglio, Olimpia; King, David R.; Risberg, Annette

    2017-01-01

    The advantage of speed is often invoked by academics and practitioners as an essential condition during post-acquisition integration, frequently without consideration of the impact earlier decisions have on acquisition speed. In this article, we examine the role speed plays in acquisitions across...... the acquisition process using research organized around characteristics that display complexity with respect to acquisition speed. We incorporate existing research with a process perspective of acquisitions in order to present trade-offs, and consider the influence of both stakeholders and the pre......-deal-completion context on acquisition speed, as well as the organization’s capabilities to facilitating that speed. Observed trade-offs suggest both that acquisition speed often requires longer planning time before an acquisition and that associated decisions require managerial judgement. A framework for improving...

  14. A DSP controlled data acquisition system for CELSIUS

    International Nuclear Information System (INIS)

    Bengtsson, M.; Lofnes, T.; Ziemann, V.

    2000-01-01

    We describe a data acquisition system based on two 10 MHz A/D-converters, a SHARC Digital Signal Processor (DSP), and a digital synthesizer used for triggering the A/D-converters. The temporal macrostructure of the data acquisition can be determined by external triggers or by timer interrupts from the DSP. In this way up to two million samples can be stored in DSP external memory. The samples are analyzed by directly fast Fourier transforming blocks of samples. In another mode we use software-based downmixing and filtering techniques to increase the resolution and zoom in on a small frequency band. Spectra of up to 5 MHz can be manipulated and displayed as waterfall plots or spectral maps on the host computer directly. Moreover, signals of up to 70 MHz can be analyzed by undersampling techniques. We use this system to analyze Schottky spectra from electron-cooled ion beams in CELSIUS and report drag rate measurements and observations of instabilities

  15. A DSP controlled data acquisition system for CELSIUS

    CERN Document Server

    Bengtsson, M; Ziemann, Volker

    2000-01-01

    We describe a data acquisition system based on two 10 MHz A/D-converters, a SHARC Digital Signal Processor (DSP), and a digital synthesizer used for triggering the A/D-converters. The temporal macrostructure of the data acquisition can be determined by external triggers or by timer interrupts from the DSP. In this way up to two million samples can be stored in DSP external memory. The samples are analyzed by directly fast Fourier transforming blocks of samples. In another mode we use software-based downmixing and filtering techniques to increase the resolution and zoom in on a small frequency band. Spectra of up to 5 MHz can be manipulated and displayed as waterfall plots or spectral maps on the host computer directly. Moreover, signals of up to 70 MHz can be analyzed by undersampling techniques. We use this system to analyze Schottky spectra from electron-cooled ion beams in CELSIUS and report drag rate measurements and observations of instabilities.

  16. Experiment data acquisition and analysis system. Vol. 1

    International Nuclear Information System (INIS)

    Busch, F.; Croome, D.; Goeringer, H.; Hartmann, V.; Lowsky, J.; Marinescu, D.; Richter, M.; Winkelmann, K.

    1983-08-01

    The Experiment Data Acquisition and Analysis System EDAS was created to acquire and analyze data collected in experiments carried out at the heavy ion accelerator UNILAC. It has been available since 1975 and has become the most frequently used system for evaluating experiments at GSI. EDAS has undergone constant development, and the many enhancements make this completely revised third edition of the EDAS manual necessary. EDAS consists of two sub-systems: GOLDA for experimental data acquisition on PDP-11's and SATAN mainly for off-line analysis in replay mode on large IBM mainframes. The capacity of one IBM 3081 CPU is mainly dedicated to EDAS processing and is almost fully utilized by this application. More than 200 users from GSI as well as from collaborating laboratories and universities use SATAN in more than 100 sessions daily needing 10 to 20 hours of user CPU time. EDAS is designed as an open system. (orig./HSI)

  17. Acquisition of German pluralization rules in monolingual and multilingual children

    Directory of Open Access Journals (Sweden)

    Eugen Zaretsky

    2013-10-01

    Full Text Available Existing studies on plural acquisition in German have relied on small samples and thus hardly deliver generalizable and differentiated results. Here, overgeneralizations of certain plural allomorphs and other tendencies in the acquisition of German plural markers are described on the basis of test data from 7,394 3- to 5-yearold monolingual German and bi/multilingual immigrant children tested with a modified, validated version of the Marburger Sprachscreening (MSS language test and 476 children tested with the SETK 3-5 language test. Classified correct and wrong answers to MSS and SETK 3-5 plural items were compared. The acquisition patterns of immigrants corresponded to those of younger German children. Both monolingual German and immigrant children demonstrated generally the same universal frequency and phonetically/phonologically based error patterns, irrespective of their linguistic background, but with different tendencies such as overgeneralization of -s by German children only.

  18. A thermal manikin with human thermoregulatory control: implementation and validation.

    Science.gov (United States)

    Foda, Ehab; Sirén, Kai

    2012-09-01

    Tens of different sorts of thermal manikins are employed worldwide, mainly in the evaluation of clothing thermal insulation and thermal environments. They are regulated thermally using simplified control modes. This paper reports on the implementation and validation of a new thermoregulatory control mode for thermal manikins. The new control mode is based on a multi-segmental Pierce (MSP) model. In this study, the MSP control mode was implemented, using the LabVIEW platform, onto the control system of the thermal manikin 'Therminator'. The MSP mode was then used to estimate the segmental equivalent temperature (t(eq)) along with constant surface temperature (CST) mode under two asymmetric thermal conditions. Furthermore, subjective tests under the same two conditions were carried out using 17 human subjects. The estimated segmental t(eq) from the experiments with the two modes and from the subjective assessment were compared in order to validate the use of the MSP mode for the estimation of t(eq). The results showed that the t(eq) values estimated by the MSP mode were closer to the subjective mean votes under the two test conditions for most body segments and compared favourably with values estimated by the CST mode.

  19. Piezoelectric transducer parameter selection for exciting a single mode from multiple modes of Lamb waves

    International Nuclear Information System (INIS)

    Zhang Hai-Yan; Yu Jian-Bo

    2011-01-01

    Excitation and propagation of Lamb waves by using rectangular and circular piezoelectric transducers surface-bonded to an isotropic plate are investigated in this work. Analytical stain wave solutions are derived for the two transducer shapes, giving the responses of these transducers in Lamb wave fields. The analytical study is supported by a numerical simulation using the finite element method. Symmetric and antisymmetric components in the wave propagation responses are inspected in detail with respect to test parameters such as the transducer geometry, the length and the excitation frequency. By placing only one piezoelectric transducer on the top or the bottom surface of the plate and weakening the strength of one mode while enhancing the strength of the other modes to find the centre frequency, with which the peak wave amplitude ratio between the S0 and A0 modes is maximum, a single mode excitation from the multiple modes of the Lamb waves can be achieved approximately. Experimental data are presented to show the validity of the analyses. The results are used to optimize the Lamb wave detection system. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  20. New partially parallel acquisition technique in cerebral imaging: preliminary findings

    International Nuclear Information System (INIS)

    Tintera, Jaroslav; Gawehn, Joachim; Bauermann, Thomas; Vucurevic, Goran; Stoeter, Peter

    2004-01-01

    In MRI applications where short acquisition time is necessary, the increase of acquisition speed is often at the expense of image resolution and SNR. In such cases, the newly developed parallel acquisition techniques could provide images without mentioned limitations and in reasonably shortened measurement time. A newly designed eight-channel head coil array (i-PAT coil) allowing for parallel acquisition of independently reconstructed images (GRAPPA mode) has been tested for its applicability in neuroradiology. Image homogeneity was tested in standard phantom and healthy volunteers. BOLD signal changes were studied in a group of six volunteers using finger tapping stimulation. Phantom studies revealed an important drop of signal even after the use of a normalization filter in the center of the image and an important increase of artifact power with reduction of measurement time strongly depending on the combination of acceleration parameters. The additional application of a parallel acquisition technique such as GRAPPA decreases measurement time in the range of about 30%, but further reduction is often possible only at the expense of SNR. This technique performs best in conditions in which imaging speed is important, such as CE MRA, but time resolution still does not allow the acquisition of angiograms separating the arterial and venous phase. Significantly larger areas of BOLD activation were found using the i-PAT coil compared to the standard head coil. Being an eight-channel surface coil array, peripheral cortical structures profit from high SNR as high-resolution imaging of small cortical dysplasias and functional activation of cortical areas imaged by BOLD contrast. In BOLD contrast imaging, susceptibility artifacts are reduced, but only if an appropriate combination of acceleration parameters is used. (orig.)

  1. New partially parallel acquisition technique in cerebral imaging: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Tintera, Jaroslav [Institute for Clinical and Experimental Medicine, Prague (Czech Republic); Gawehn, Joachim; Bauermann, Thomas; Vucurevic, Goran; Stoeter, Peter [University Clinic Mainz, Institute of Neuroradiology, Mainz (Germany)

    2004-12-01

    In MRI applications where short acquisition time is necessary, the increase of acquisition speed is often at the expense of image resolution and SNR. In such cases, the newly developed parallel acquisition techniques could provide images without mentioned limitations and in reasonably shortened measurement time. A newly designed eight-channel head coil array (i-PAT coil) allowing for parallel acquisition of independently reconstructed images (GRAPPA mode) has been tested for its applicability in neuroradiology. Image homogeneity was tested in standard phantom and healthy volunteers. BOLD signal changes were studied in a group of six volunteers using finger tapping stimulation. Phantom studies revealed an important drop of signal even after the use of a normalization filter in the center of the image and an important increase of artifact power with reduction of measurement time strongly depending on the combination of acceleration parameters. The additional application of a parallel acquisition technique such as GRAPPA decreases measurement time in the range of about 30%, but further reduction is often possible only at the expense of SNR. This technique performs best in conditions in which imaging speed is important, such as CE MRA, but time resolution still does not allow the acquisition of angiograms separating the arterial and venous phase. Significantly larger areas of BOLD activation were found using the i-PAT coil compared to the standard head coil. Being an eight-channel surface coil array, peripheral cortical structures profit from high SNR as high-resolution imaging of small cortical dysplasias and functional activation of cortical areas imaged by BOLD contrast. In BOLD contrast imaging, susceptibility artifacts are reduced, but only if an appropriate combination of acceleration parameters is used. (orig.)

  2. Modified complementary ensemble empirical mode decomposition and intrinsic mode functions evaluation index for high-speed train gearbox fault diagnosis

    Science.gov (United States)

    Chen, Dongyue; Lin, Jianhui; Li, Yanping

    2018-06-01

    Complementary ensemble empirical mode decomposition (CEEMD) has been developed for the mode-mixing problem in Empirical Mode Decomposition (EMD) method. Compared to the ensemble empirical mode decomposition (EEMD), the CEEMD method reduces residue noise in the signal reconstruction. Both CEEMD and EEMD need enough ensemble number to reduce the residue noise, and hence it would be too much computation cost. Moreover, the selection of intrinsic mode functions (IMFs) for further analysis usually depends on experience. A modified CEEMD method and IMFs evaluation index are proposed with the aim of reducing the computational cost and select IMFs automatically. A simulated signal and in-service high-speed train gearbox vibration signals are employed to validate the proposed method in this paper. The results demonstrate that the modified CEEMD can decompose the signal efficiently with less computation cost, and the IMFs evaluation index can select the meaningful IMFs automatically.

  3. Neutron flux control systems validation

    International Nuclear Information System (INIS)

    Hascik, R.

    2003-01-01

    In nuclear installations main requirement is to obtain corresponding nuclear safety in all operation conditions. From the nuclear safety point of view is commissioning and start-up after reactor refuelling appropriate period for safety systems verification. In this paper, methodology, performance and results of neutron flux measurements systems validation is presented. Standard neutron flux measuring chains incorporated into the reactor protection and control system are used. Standard neutron flux measuring chain contains detector, preamplifier, wiring to data acquisition unit, data acquisition unit, wiring to display at control room and display at control room. During reactor outage only data acquisition unit and wiring and displaying at reactor control room is verified. It is impossible to verify detector, preamplifier and wiring to data acquisition recording unit during reactor refuelling according to low power. Adjustment and accurate functionality of these chains is confirmed by start-up rate (SUR) measurement during start-up tests after refuelling of the reactors. This measurement has direct impact to nuclear safety and increase operational nuclear safety level. Briefly description of each measuring system is given. Results are illustrated on measurements performed at Bohunice NPP during reactor start-up tests. Main failures and their elimination are described (Authors)

  4. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    Energy Technology Data Exchange (ETDEWEB)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M [Grupo de Fisica Nuclear, Departmento de Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid (Spain); Vaquero, J J; Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain)], E-mail: jose@nuc2.fis.ucm.es

    2009-03-21

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  5. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    International Nuclear Information System (INIS)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M; Vaquero, J J; Desco, M

    2009-01-01

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  6. Impact of gain saturation on the mode instability threshold in high-power fiber amplifiers

    DEFF Research Database (Denmark)

    Hansen, Kristian Rymann; Lægsgaard, Jesper

    2014-01-01

    We present a coupled-mode model of transverse mode instability in high-power fiber amplifiers, which takes the effect of gain saturation into account. The model provides simple semi-analytical formulas for the mode instability threshold, which are valid also for highly saturated amplifiers...

  7. CONTROL: the run control program used on the WA62 VAX data acquisition system at CERN

    International Nuclear Information System (INIS)

    Hand, R.P.

    1980-11-01

    The criteria are described which have been used in the design of CONTROL, a program in the WA62 VAX Native mode data acquisition system which serves the triple purpose of driving a status display, an operator's console and a message reporter. (U.K.)

  8. Overview of data acquisition system for SST-1 diagnostics

    International Nuclear Information System (INIS)

    Sharma, Manika; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-01-01

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  9. Overview of data acquisition system for SST-1 diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manika, E-mail: bithi@ipr.res.in; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-11-15

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  10. Demonstration of the CDMA-mode CAOS smart camera.

    Science.gov (United States)

    Riza, Nabeel A; Mazhar, Mohsin A

    2017-12-11

    Demonstrated is the code division multiple access (CDMA)-mode coded access optical sensor (CAOS) smart camera suited for bright target scenarios. Deploying a silicon CMOS sensor and a silicon point detector within a digital micro-mirror device (DMD)-based spatially isolating hybrid camera design, this smart imager first engages the DMD starring mode with a controlled factor of 200 high optical attenuation of the scene irradiance to provide a classic unsaturated CMOS sensor-based image for target intelligence gathering. Next, this CMOS sensor provided image data is used to acquire a focused zone more robust un-attenuated true target image using the time-modulated CDMA-mode of the CAOS camera. Using four different bright light test target scenes, successfully demonstrated is a proof-of-concept visible band CAOS smart camera operating in the CDMA-mode using up-to 4096 bits length Walsh design CAOS pixel codes with a maximum 10 KHz code bit rate giving a 0.4096 seconds CAOS frame acquisition time. A 16-bit analog-to-digital converter (ADC) with time domain correlation digital signal processing (DSP) generates the CDMA-mode images with a 3600 CAOS pixel count and a best spatial resolution of one micro-mirror square pixel size of 13.68 μm side. The CDMA-mode of the CAOS smart camera is suited for applications where robust high dynamic range (DR) imaging is needed for un-attenuated un-spoiled bright light spectrally diverse targets.

  11. Rayleigh scattering in few-mode optical fibers.

    Science.gov (United States)

    Wang, Zhen; Wu, Hao; Hu, Xiaolong; Zhao, Ningbo; Mo, Qi; Li, Guifang

    2016-10-24

    The extremely low loss of silica fibers has enabled the telecommunication revolution, but single-mode fiber-optic communication systems have been driven to their capacity limits. As a means to overcome this capacity crunch, space-division multiplexing (SDM) using few-mode fibers (FMF) has been proposed and demonstrated. In single-mode optical fibers, Rayleigh scattering serves as the dominant mechanism for optical loss. However, to date, the role of Rayleigh scattering in FMFs remains elusive. Here we establish and experimentally validate a general model for Rayleigh scattering in FMFs. Rayleigh backscattering not only sets the intrinsic loss limit for FMFs but also provides the theoretical foundation for few-mode optical time-domain reflectometry, which can be used to probe perturbation-induced mode-coupling dynamics in FMFs. We also show that forward inter-modal Rayleigh scattering ultimately sets a fundamental limit on inter-modal-crosstalk for FMFs. Therefore, this work not only has implications specifically for SDM systems but also broadly for few-mode fiber optics and its applications in amplifiers, lasers, and sensors in which inter-modal crosstalk imposes a fundamental performance limitation.

  12. Particle Distribution Modification by Low Amplitude Modes

    International Nuclear Information System (INIS)

    White, R.B.; Gorelenkov, N.; Heidbrink, W.W.; Van Zeeland, M.A.

    2009-01-01

    Modification of a high energy particle distribution by a spectrum of low amplitude modes is investigated using a guiding center code. Only through resonance are modes effective in modifying the distribution. Diagnostics are used to illustrate the mode-particle interaction and to find which effects are relevant in producing significant resonance, including kinetic Poincare plots and plots showing those orbits with time averaged mode-particle energy transfer. Effects of pitch angle scattering and drag are studied, as well as plasma rotation and time dependence of the equilibrium and mode frequencies. A specific example of changes observed in a DIII-D deuterium beam distribution in the presence of low amplitude experimentally validated Toroidal Alfven (TAE) eigenmodes and Reversed Shear Alfven (RSAE) eigenmodes is examined in detail. Comparison with experimental data shows that multiple low amplitude modes can account for significant modification of high energy beam particle distributions. It is found that there is a stochastic threshold for beam profile modification, and that the experimental amplitudes are only slightly above this threshold.

  13. Cosmic Origins Spectrograph: On-Orbit Performance of Target Acquisitions

    Science.gov (United States)

    Penton, Steven V.

    2010-07-01

    COS is a slit-less spectrograph with a very small aperture (R=1.2500). To achieve the desired wavelength accuracies, HST+COS must center the target to within 0.100 of the center of the aperture for the FUV channel, and 0.0400 for NUV. During SMOV and early Cycle 17 we fine-tuned the COS target acquisition (TA) procedures to exceed this accuracy for all three COS TA modes; NUV imaging, NUV spectroscopic, and FUV spectroscopic. In Cycle 17, we also adjusted the COSto- FGS offsets in the SIAF file. This allows us to recommend skipping the time consuming ACQ/SEARCH in cases where the target coordinates are well known. Here we will compare the on-orbit performance of all COS TA modes in terms of centering accuracy, efficiency, and required signal-to-noise (S/N).

  14. Mode of foreign entry, technology transfer, and foreign direct investment policy

    OpenAIRE

    Mattoo, Aaditya; Olarreaga, Marcelo; Saggi, Kamal

    2001-01-01

    Foreign direct investment can take place through the direct entry of foreign firms or the acquisition of existing domestic firms. Mattoo, Olarreaga, and Saggi examine the preferences of a foreign firm and the host country government with respect to these two modes of foreign direct investment in the presence of costly technology transfer. The tradeoff between technology transfer and market...

  15. X-windows-based user interface for data acquisition and display

    International Nuclear Information System (INIS)

    Fredian, T.W.; Stillerman, J.A.

    1990-01-01

    A Macintosh-like user interface for the MDS-Plus data acquisition system is being implemented using the DECwindows MIT/X interface. MDS-Plus is a model driven general purpose data acquisition system being developed collaboratively by the CMOD group at MIT Plasma Fusion Center, the RFX group at IGI-Padua, and the ZTH group at Los Alamos National Laboratory. The model is a hierarchical description of an experiment, including all of the tasks to be performed and the results of having performed them. The inherent complexity of this experimental model requires the users to specify fairly complicated descriptions of what they want the system to do. A ''Point and Click'' interface simplifies this by presenting to the user a coherent set of choices which are valid in the current context. We are implementing a set of tools for data acquisition and data analysis which use DECwindows to this end. They include a data displayer (Scope Replacement), an experiment model editor (Tree Editor), a timing system, and a waveform editor. These tools provide an easy to use interface to the MDS-Plus data acquisition system

  16. Experimental data and boundary conditions for a Double - Skin Facade building in transparent insulation mode

    DEFF Research Database (Denmark)

    Larsen, Olena Kalyanova; Heiselberg, Per; Jensen, Rasmus Lund

    was carried out in a full scale test facility ‘The Cube’, in order to compile three sets of high quality experimental data for validation purposes. The data sets are available for preheating mode, external air curtain mode and transparent insulation mode. The objective of this article is to provide the reader...... with all information about the experimental data and measurements, necessary to complete an independent empirical validation of any simulation tool. The article includes detailed information about the experimental apparatus, experimental principles and experimental full-scale test facility ‘The Cube...

  17. Smart acquisition EELS

    International Nuclear Information System (INIS)

    Sader, Kasim; Schaffer, Bernhard; Vaughan, Gareth; Brydson, Rik; Brown, Andy; Bleloch, Andrew

    2010-01-01

    We have developed a novel acquisition methodology for the recording of electron energy loss spectra (EELS) using a scanning transmission electron microscope (STEM): 'Smart Acquisition'. Smart Acquisition allows the independent control of probe scanning procedures and the simultaneous acquisition of analytical signals such as EELS. The original motivation for this work arose from the need to control the electron dose experienced by beam-sensitive specimens whilst maintaining a sufficiently high signal-to-noise ratio in the EEL signal for the extraction of useful analytical information (such as energy loss near edge spectral features) from relatively undamaged areas. We have developed a flexible acquisition framework which separates beam position data input, beam positioning, and EELS acquisition. In this paper we demonstrate the effectiveness of this technique on beam-sensitive thin films of amorphous aluminium trifluoride. Smart Acquisition has been used to expose lines to the electron beam, followed by analysis of the structures created by line-integrating EELS acquisitions, and the results are compared to those derived from a standard EELS linescan. High angle annular dark-field images show clear reductions in damage for the Smart Acquisition areas compared to the conventional linescan, and the Smart Acquisition low loss EEL spectra are more representative of the undamaged material than those derived using a conventional linescan. Atomically resolved EELS of all four elements of CaNdTiO show the high resolution capabilities of Smart Acquisition.

  18. Smart acquisition EELS

    Energy Technology Data Exchange (ETDEWEB)

    Sader, Kasim, E-mail: k.sader@leeds.ac.uk [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Schaffer, Bernhard [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Department of Physics and Astronomy, University of Glasgow (United Kingdom); Vaughan, Gareth [Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Brydson, Rik [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Brown, Andy [Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Bleloch, Andrew [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Department of Engineering, University of Liverpool, Liverpool (United Kingdom)

    2010-07-15

    We have developed a novel acquisition methodology for the recording of electron energy loss spectra (EELS) using a scanning transmission electron microscope (STEM): 'Smart Acquisition'. Smart Acquisition allows the independent control of probe scanning procedures and the simultaneous acquisition of analytical signals such as EELS. The original motivation for this work arose from the need to control the electron dose experienced by beam-sensitive specimens whilst maintaining a sufficiently high signal-to-noise ratio in the EEL signal for the extraction of useful analytical information (such as energy loss near edge spectral features) from relatively undamaged areas. We have developed a flexible acquisition framework which separates beam position data input, beam positioning, and EELS acquisition. In this paper we demonstrate the effectiveness of this technique on beam-sensitive thin films of amorphous aluminium trifluoride. Smart Acquisition has been used to expose lines to the electron beam, followed by analysis of the structures created by line-integrating EELS acquisitions, and the results are compared to those derived from a standard EELS linescan. High angle annular dark-field images show clear reductions in damage for the Smart Acquisition areas compared to the conventional linescan, and the Smart Acquisition low loss EEL spectra are more representative of the undamaged material than those derived using a conventional linescan. Atomically resolved EELS of all four elements of CaNdTiO show the high resolution capabilities of Smart Acquisition.

  19. Higher Order Modes Excitation of Micro Cantilever Beams

    KAUST Repository

    Jaber, Nizar

    2014-05-01

    In this study, we present analytical and experimental investigation of electrically actuated micro cantilever based resonators. These devices are fabricated using polyimide and coated with chrome and gold layers from both sides. The cantilevers are highly curled up due to stress gradient, which is a common imperfection in surface micro machining. Using a laser Doppler vibrometer, we applied a noise signal to experimentally find the first four resonance frequencies. Then, using a data acquisition card, we swept the excitation frequency around the first four natural modes of vibrations. Theoretically, we derived a reduced order model using the Galerkin method to simulate the dynamics of the system. Extensive numerical analysis and computations were performed. The numerical analysis was able to provide good matching with experimental values of the resonance frequencies. Also, we proved the ability to excite higher order modes using partial electrodes with shapes that resemble the shape of the mode of interest. Such micro-resonators are shown to be promising for applications in mass and gas sensing.

  20. CMB v. 1.1 Data Acquisition and Evaluation System of the Cracow Nuclear Microprobe

    International Nuclear Information System (INIS)

    Lekki, J.; Hajduk, R.; Potempa, A.; Pieprzyca, T.; Stachura, Z.; Zieblinski, M.; Styczen, J.; Lebed, S.

    2000-11-01

    An overview of the Cracow nuclear microprobe together with its data acquisition and control system is presented. Magnetic deflection was applied for beam scanning, while detector signals acquisition is performed by the NIM/CAMAC modules under supervision of a Windows operating system running on a PC equipped with the GPIB controller card. Total spectra from every detector are accessible on-line during the measurement, while full information about detected energy and beam position is stored to a disk file in the list mode to allow off-line data analysis. System hardware and software setups together with software operations and data formats used for information storing are described. (author)

  1. CAMAC data acquisition system for the pelletron

    International Nuclear Information System (INIS)

    Chatterjee, A.; Ghodgaonkar, M.D.; Khare, A.N.

    1993-01-01

    We have developed a CAMAC data acquisition system to meet the needs of a broad range of experiments at the pelletron. The system makes use of the DMA CAMAC crate controller CC3. The system is designed around two configurations. In the first, the crate controller is interfaced to an IBM PC/AT. The data are acquired on the PC Winchester disk. In the second configuration, the IBM PC is further linked to a HORIZON III mini-computer via ethernet. In this case list mode data can be taken directly on 1/2-inch reel tapes or 60MB cartridges. (author). 3 refs., 2 figs

  2. Real time data acquisition system for the High Current Test Facility proton accelerator

    International Nuclear Information System (INIS)

    Langlais, C.E.; Erickson, P.D.; Caissie, L.P.

    1975-01-01

    A real time data acquisition system was developed to monitor and control the High Current Test Facility Proton Accelerator. It is a PDP-8/E computer system with virtual memory capability that is fully interrupt driven and operates under a real-time, multi-tasking executive. The application package includes mode selection to automatically modify programs and optimize operation under varying conditions. (U.S.)

  3. Pre-study and in-study validation of a size-exclusion chromatography method with different detection modes for the analysis of monoclonal antibody aggregates.

    Science.gov (United States)

    Oliva, Alexis; Fariña, Jose B; Llabrés, Matías

    2016-06-01

    Size exclusion chromatography (SEC) with different detection modes was assessed as a means to characterize the type of bevacizumab aggregate that forms under thermal stress, quantitatively monitoring the aggregation kinetics. The combination of SEC with light-scattering (SEC/LS) detection was validated using in-study validation process. This was performed by applying a strategy based on a control chart to monitor the process parameters and by inserting quality control samples in routine runs. The SEC coupled with a differential refractive-index detector (SEC/RI) was validated using a pre-study validation process in accordance with the ICH-Q2 (R1) guidelines and in-study monitoring in accordance with the Analytical Target Profile (ATP) criteria. The total error and β-expectation tolerance interval rules were used to assess method suitability and control the risk of incorrectly accepting unsuitable analytical methods. The aggregation kinetics data were interpreted using a modified Lumry-Eyring model. The true order of the reaction was determined using the initial-rate approach. All the kinetic data show a linear Arrhenius dependence within the studied temperature range. The Arrhenius approach over-predicted the aggregation rate for 5°C, but provides an idea of the aggregation process and amount of aggregate formed. In any case, real-time stability data are necessary to establish the product shelf-life. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Image acquisition, transmission and assignment in 60Co container inspection system

    International Nuclear Information System (INIS)

    Wu Zhifang; Zhou Liye; Liu Ximing; Wang Liqiang

    1999-01-01

    The author describes the data acquisition mode and image reconstruction method in 60 Co container inspection system, analyzes the relationship between line pick period and geometry distortion, makes clear the demand to data transmitting rate. It discusses several data communication methods, draws up a plan for network, realizes automatic direction and reasonable assignment of data in the system, cooperation of multi-computer and parallel processing, thus greatly improves the systems inspection efficiency

  5. Family involvement and firms’ establishment mode choice in foreign markets

    OpenAIRE

    Boellis, Andrea; Mariotti, Sergio; Minichilli, Alessandro; Piscitello, Lucia

    2016-01-01

    Extant literature on foreign entry increasingly recognizes firms’ heterogeneity as a potential reason for inconsistency in results on the establishment mode choice, that is, whether and under which conditions firms should choose to enter a new country through a greenfield investment or an acquisition. Our study contributes to this debate by identifying family ownership and family involvement in management as potential powerful sources of such heterogeneity. Integrating international business ...

  6. Design and performance of an acquisition and control system for a positron camera with novel detectors

    International Nuclear Information System (INIS)

    Symonds-Tayler, J.R.N.; Reader, A.J.; Flower, M.A.

    1996-01-01

    A Sun-based data acquisition and control (DAQ) system has been designed for PETRRA, a whole-body positron camera using large-area BaF 2 -TMAE detectors. The DAQ system uses a high-speed digital I/O card (S16D) installed on the S-bus of a SPARC10 and a specially-designed Positron Camera Interface (PCI), which also controls both the gantry and horizontal couch motion. Data in the form of different types of 6-byte packets are acquired in list mode. Tests with a signal generator show that the DAQ system should be able to cater for coincidence count-rates up to 100 kcps. The predicted count loss due to the DAQ system is ∼13% at this count rate, provided asynchronous-read based software is used. The list-mode data acquisition system designed for PETRRA could be adapted for other 3D PET cameras with similar data rates

  7. Language Acquisition without an Acquisition Device

    Science.gov (United States)

    O'Grady, William

    2012-01-01

    Most explanatory work on first and second language learning assumes the primacy of the acquisition phenomenon itself, and a good deal of work has been devoted to the search for an "acquisition device" that is specific to humans, and perhaps even to language. I will consider the possibility that this strategy is misguided and that language…

  8. Unconstrained Iris Acquisition and Recognition Using COTS PTZ Camera

    Directory of Open Access Journals (Sweden)

    Venugopalan Shreyas

    2010-01-01

    Full Text Available Abstract Uniqueness of iris patterns among individuals has resulted in the ubiquity of iris recognition systems in virtual and physical spaces, at high security facilities around the globe. Traditional methods of acquiring iris patterns in commercial systems scan the iris when an individual is at a predetermined location in front of the scanner. Most state-of-the-art techniques for unconstrained iris acquisition in literature use expensive custom equipment and are composed of a multicamera setup, which is bulky, expensive, and requires calibration. This paper investigates a method of unconstrained iris acquisition and recognition using a single commercial off-the-shelf (COTS pan-tilt-zoom (PTZ camera, that is compact and that reduces the cost of the final system, compared to other proposed hierarchical multicomponent systems. We employ state-of-the-art techniques for face detection and a robust eye detection scheme using active shape models for accurate landmark localization. Additionally, our system alleviates the need for any calibration stage prior to its use. We present results using a database of iris images captured using our system, while operating in an unconstrained acquisition mode at 1.5 m standoff, yielding an iris diameter in the 150–200 pixels range.

  9. Ultra-low dose CT attenuation correction for PET/CT: analysis of sparse view data acquisition and reconstruction algorithms

    Science.gov (United States)

    Rui, Xue; Cheng, Lishui; Long, Yong; Fu, Lin; Alessio, Adam M.; Asma, Evren; Kinahan, Paul E.; De Man, Bruno

    2015-01-01

    For PET/CT systems, PET image reconstruction requires corresponding CT images for anatomical localization and attenuation correction. In the case of PET respiratory gating, multiple gated CT scans can offer phase-matched attenuation and motion correction, at the expense of increased radiation dose. We aim to minimize the dose of the CT scan, while preserving adequate image quality for the purpose of PET attenuation correction by introducing sparse view CT data acquisition. Methods We investigated sparse view CT acquisition protocols resulting in ultra-low dose CT scans designed for PET attenuation correction. We analyzed the tradeoffs between the number of views and the integrated tube current per view for a given dose using CT and PET simulations of a 3D NCAT phantom with lesions inserted into liver and lung. We simulated seven CT acquisition protocols with {984, 328, 123, 41, 24, 12, 8} views per rotation at a gantry speed of 0.35 seconds. One standard dose and four ultra-low dose levels, namely, 0.35 mAs, 0.175 mAs, 0.0875 mAs, and 0.04375 mAs, were investigated. Both the analytical FDK algorithm and the Model Based Iterative Reconstruction (MBIR) algorithm were used for CT image reconstruction. We also evaluated the impact of sinogram interpolation to estimate the missing projection measurements due to sparse view data acquisition. For MBIR, we used a penalized weighted least squares (PWLS) cost function with an approximate total-variation (TV) regularizing penalty function. We compared a tube pulsing mode and a continuous exposure mode for sparse view data acquisition. Global PET ensemble root-mean-squares-error (RMSE) and local ensemble lesion activity error were used as quantitative evaluation metrics for PET image quality. Results With sparse view sampling, it is possible to greatly reduce the CT scan dose when it is primarily used for PET attenuation correction with little or no measureable effect on the PET image. For the four ultra-low dose levels

  10. Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

    Science.gov (United States)

    Liu, Yilin; Yin, Fang-Fang; Rhee, DongJoo; Cai, Jing

    2016-01-01

    The authors have recently developed a cine-mode T2*/T1-weighted 4D-MRI technique and a sequential-mode T2-weighted 4D-MRI technique for imaging respiratory motion. This study aims at investigating which 4D-MRI image acquisition mode, cine or sequential, provides more accurate measurement of organ motion during respiration. A 4D digital extended cardiac-torso (XCAT) human phantom with a hypothesized tumor was used to simulate the image acquisition and the 4D-MRI reconstruction. The respiratory motion was controlled by the given breathing signal profiles. The tumor was manipulated to move continuously with the surrounding tissue. The motion trajectories were measured from both sequential- and cine-mode 4D-MRI images. The measured trajectories were compared with the average trajectory calculated from the input profiles, which was used as references. The error in 4D-MRI tumor motion trajectory (E) was determined. In addition, the corresponding respiratory motion amplitudes of all the selected 2D images for 4D reconstruction were recorded. Each of the amplitude was compared with the amplitude of its associated bin on the average breathing curve. The mean differences from the average breathing curve across all slice positions (D) were calculated. A total of 500 simulated respiratory profiles with a wide range of irregularity (Ir) were used to investigate the relationship between D and Ir. Furthermore, statistical analysis of E and D using XCAT controlled by 20 cancer patients' breathing profiles was conducted. Wilcoxon Signed Rank test was conducted to compare two modes. D increased faster for cine-mode (D = 1.17 × Ir + 0.23) than sequential-mode (D = 0.47 × Ir + 0.23) as irregularity increased. For the XCAT study using 20 cancer patients' breathing profiles, the median E values were significantly different: 0.12 and 0.10 cm for cine- and sequential-modes, respectively, with a p-value of 0.02. The median D values were significantly different: 0.47 and 0.24 cm for cine

  11. Image acquisition and interpretation criteria for 99mTc-HMPAO-labelled white blood cell scintigraphy: results of a multicentre study

    International Nuclear Information System (INIS)

    Erba, Paola A.; Glaudemans, Andor W.J.M.; Dierckx, Rudi A.J.O.; Veltman, Niels C.; Sollini, Martina; Pacilio, Marta; Galli, Filippo; Signore, Alberto; Sapienza Univ., Rome; Sapienza Univ., Rome

    2014-01-01

    There is no consensus yet on the best protocol for planar image acquisition and interpretation of radiolabelled white blood cell (WBC) scintigraphy. This may account for differences in reported diagnostic accuracy amongst different centres. This was a multicentre retrospective study analysing 235 WBC scans divided into two groups. The first group of scans (105 patients) were acquired with a fixed-time acquisition protocol and the second group (130 patients) were acquired with a decay time-corrected acquisition protocol. Planar images were interpreted both qualitatively and semiquantitatively. Three blinded readers analysed the images. The most accurate imaging acquisition protocol comprised image acquisition at 3 - 4 h and at 20 - 24 h in time mode with acquisition times corrected for isotope decay. Using this protocol, visual analysis had high sensitivity and specificity in the diagnosis of infection. Semiquantitative analysis could be used in doubtful cases, with no cut-off for the percentage increase in radiolabelled WBC over time, as a criterion to define a positive scan. (orig.)

  12. Magnetic-Field-Response Measurement-Acquisition System

    Science.gov (United States)

    Woodward, Stanley E.; Shams, Qamar A.; Fox, Robert L.; Taylor, Bryant D.

    2006-01-01

    A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a

  13. Bunch mode specific rate corrections for PILATUS3 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Trueb, P., E-mail: peter.trueb@dectris.com [DECTRIS Ltd, 5400 Baden (Switzerland); Dejoie, C. [ETH Zurich, 8093 Zurich (Switzerland); Kobas, M. [DECTRIS Ltd, 5400 Baden (Switzerland); Pattison, P. [EPF Lausanne, 1015 Lausanne (Switzerland); Peake, D. J. [School of Physics, The University of Melbourne, Victoria 3010 (Australia); Radicci, V. [DECTRIS Ltd, 5400 Baden (Switzerland); Sobott, B. A. [School of Physics, The University of Melbourne, Victoria 3010 (Australia); Walko, D. A. [Argonne National Laboratory, Argonne, IL 60439 (United States); Broennimann, C. [DECTRIS Ltd, 5400 Baden (Switzerland)

    2015-04-09

    The count rate behaviour of PILATUS3 detectors has been characterized for seven bunch modes at four different synchrotrons. The instant retrigger technology of the PILATUS3 application-specific integrated circuit is found to reduce the dependency of the required rate correction on the synchrotron bunch mode. The improvement of using bunch mode specific rate corrections based on a Monte Carlo simulation is quantified. PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanism has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.

  14. List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations

    International Nuclear Information System (INIS)

    Lamare, F; Carbayo, M J Ledesma; Cresson, T; Kontaxakis, G; Santos, A; Rest, C Cheze Le; Reader, A J; Visvikis, D

    2007-01-01

    Respiratory motion in emission tomography leads to reduced image quality. Developed correction methodology has been concentrating on the use of respiratory synchronized acquisitions leading to gated frames. Such frames, however, are of low signal-to-noise ratio as a result of containing reduced statistics. In this work, we describe the implementation of an elastic transformation within a list-mode-based reconstruction for the correction of respiratory motion over the thorax, allowing the use of all data available throughout a respiratory motion average acquisition. The developed algorithm was evaluated using datasets of the NCAT phantom generated at different points throughout the respiratory cycle. List-mode-data-based PET-simulated frames were subsequently produced by combining the NCAT datasets with Monte Carlo simulation. A non-rigid registration algorithm based on B-spline basis functions was employed to derive transformation parameters accounting for the respiratory motion using the NCAT dynamic CT images. The displacement matrices derived were subsequently applied during the image reconstruction of the original emission list mode data. Two different implementations for the incorporation of the elastic transformations within the one-pass list mode EM (OPL-EM) algorithm were developed and evaluated. The corrected images were compared with those produced using an affine transformation of list mode data prior to reconstruction, as well as with uncorrected respiratory motion average images. Results demonstrate that although both correction techniques considered lead to significant improvements in accounting for respiratory motion artefacts in the lung fields, the elastic-transformation-based correction leads to a more uniform improvement across the lungs for different lesion sizes and locations

  15. Phonology-morphology interaction: Acquisition of Danish noun plurals as a test case

    DEFF Research Database (Denmark)

    Kjærbæk, Laila; Basbøll, Hans

    2010-01-01

    Acquisition in Normal and Hearing Impaired Populations". In E. Schmidt, U. Mikkelsen, I. Post, J. B. Simonsen & K. Fruensgaard (eds.), Brain, Hearing and Learning. 20th Danavox Symposium 2003: 165-190. Bleses, D., Vach, W., Wehberg, S., Kristensen, K. F. & Madsen, T. O. (2007). Tidlig kommunikativ udvikling...... Development Inventories: Validity and Main Developmental Trends". Journal of Child Language 35, 651-69. Bleses, D., Vach, W., Slott, M., Wehberg, S., Thomsen, P., Madsen, T. & Basbøll, H. (2008b). “Early Vocabulary Development in Danish and Other Languages: a CDI-based Comparison”. Journal of Child Language...... on the Occasion of his 60th Birthday 12 July 2003. Odense: Syddansk Universitetsforlag. Slobin, D. I. (ed.) (1985a). The Crosslinguistic Study of Language Acquisition. Hillsdale, NJ: Lawrence Earlbaum Associates. Slobin, D. I. (ed.) (1985b). The Crosslinguistic Study of Language Acquisition. Hillsdale, NJ...

  16. Linear LIDAR versus Geiger-mode LIDAR: impact on data properties and data quality

    Science.gov (United States)

    Ullrich, A.; Pfennigbauer, M.

    2016-05-01

    LIDAR has become the inevitable technology to provide accurate 3D data fast and reliably even in adverse measurement situations and harsh environments. It provides highly accurate point clouds with a significant number of additional valuable attributes per point. LIDAR systems based on Geiger-mode avalanche photo diode arrays, also called single photon avalanche photo diode arrays, earlier employed for military applications, now seek to enter the commercial market of 3D data acquisition, advertising higher point acquisition speeds from longer ranges compared to conventional techniques. Publications pointing out the advantages of these new systems refer to the other category of LIDAR as "linear LIDAR", as the prime receiver element for detecting the laser echo pulses - avalanche photo diodes - are used in a linear mode of operation. We analyze the differences between the two LIDAR technologies and the fundamental differences in the data they provide. The limitations imposed by physics on both approaches to LIDAR are also addressed and advantages of linear LIDAR over the photon counting approach are discussed.

  17. A three-dimensional model for calculating the micro disk laser resonant-modes

    International Nuclear Information System (INIS)

    Sabetjoo, H.; Bahrampor, A.; Farrahi-Moghaddam, R.

    2006-01-01

    In this article, a semi-analytical model for theoretical analysis of micro disk lasers is presented. Using this model, the necessary conditions for the existence of loss less and low-loss modes of micro-resonators are obtained. The resonance frequency of the resonant modes and also the attenuation of low-loss modes are calculated. By comparing the results with results of finite difference method, their validity is certified.

  18. Real-time identification of vehicle motion-modes using neural networks

    Science.gov (United States)

    Wang, Lifu; Zhang, Nong; Du, Haiping

    2015-01-01

    A four-wheel ground vehicle has three body-dominated motion-modes, that is, bounce, roll, and pitch motion-modes. Real-time identification of these motion-modes can make vehicle suspensions, in particular, active suspensions, target on the dominant motion-mode and apply appropriate control strategies to improve its performance with less power consumption. Recently, a motion-mode energy method (MEM) was developed to identify the vehicle body motion-modes. However, this method requires the measurement of full vehicle states and road inputs, which are not always available in practice. This paper proposes an alternative approach to identify vehicle primary motion-modes with acceptable accuracy by employing neural networks (NNs). The effectiveness of the trained NNs is verified on a 10-DOF full-car model under various types of excitation inputs. The results confirm that the proposed method is effective in determining vehicle primary motion-modes with comparable accuracy to the MEM method. Experimental data is further used to validate the proposed method.

  19. Spatially resolved quantum plasmon modes in metallic nano-films from first-principles

    DEFF Research Database (Denmark)

    Andersen, Kirsten; Jacobsen, Karsten W.; Thygesen, Kristian S.

    2012-01-01

    Electron energy loss spectroscopy (EELS) can be used to probe plasmon excitations in nanostructured materials with atomic-scale spatial resolution. For structures smaller than a few nanometers, quantum effects are expected to be important, limiting the validity of widely used semiclassical response...... as (conventional) surface modes, subsurface modes, and a discrete set of bulk modes resembling standing waves across the film. We find clear effects of both quantum confinement and nonlocal response. The quantum plasmon modes provide an intuitive picture of collective excitations of confined electron systems...

  20. Using Healthcare Failure Mode and Effect Analysis to reduce medication errors in the process of drug prescription, validation and dispensing in hospitalised patients.

    Science.gov (United States)

    Vélez-Díaz-Pallarés, Manuel; Delgado-Silveira, Eva; Carretero-Accame, María Emilia; Bermejo-Vicedo, Teresa

    2013-01-01

    To identify actions to reduce medication errors in the process of drug prescription, validation and dispensing, and to evaluate the impact of their implementation. A Health Care Failure Mode and Effect Analysis (HFMEA) was supported by a before-and-after medication error study to measure the actual impact on error rate after the implementation of corrective actions in the process of drug prescription, validation and dispensing in wards equipped with computerised physician order entry (CPOE) and unit-dose distribution system (788 beds out of 1080) in a Spanish university hospital. The error study was carried out by two observers who reviewed medication orders on a daily basis to register prescription errors by physicians and validation errors by pharmacists. Drugs dispensed in the unit-dose trolleys were reviewed for dispensing errors. Error rates were expressed as the number of errors for each process divided by the total opportunities for error in that process times 100. A reduction in prescription errors was achieved by providing training for prescribers on CPOE, updating prescription procedures, improving clinical decision support and automating the software connection to the hospital census (relative risk reduction (RRR), 22.0%; 95% CI 12.1% to 31.8%). Validation errors were reduced after optimising time spent in educating pharmacy residents on patient safety, developing standardised validation procedures and improving aspects of the software's database (RRR, 19.4%; 95% CI 2.3% to 36.5%). Two actions reduced dispensing errors: reorganising the process of filling trolleys and drawing up a protocol for drug pharmacy checking before delivery (RRR, 38.5%; 95% CI 14.1% to 62.9%). HFMEA facilitated the identification of actions aimed at reducing medication errors in a healthcare setting, as the implementation of several of these led to a reduction in errors in the process of drug prescription, validation and dispensing.

  1. FastaValidator: an open-source Java library to parse and validate FASTA formatted sequences.

    Science.gov (United States)

    Waldmann, Jost; Gerken, Jan; Hankeln, Wolfgang; Schweer, Timmy; Glöckner, Frank Oliver

    2014-06-14

    Advances in sequencing technologies challenge the efficient importing and validation of FASTA formatted sequence data which is still a prerequisite for most bioinformatic tools and pipelines. Comparative analysis of commonly used Bio*-frameworks (BioPerl, BioJava and Biopython) shows that their scalability and accuracy is hampered. FastaValidator represents a platform-independent, standardized, light-weight software library written in the Java programming language. It targets computer scientists and bioinformaticians writing software which needs to parse quickly and accurately large amounts of sequence data. For end-users FastaValidator includes an interactive out-of-the-box validation of FASTA formatted files, as well as a non-interactive mode designed for high-throughput validation in software pipelines. The accuracy and performance of the FastaValidator library qualifies it for large data sets such as those commonly produced by massive parallel (NGS) technologies. It offers scientists a fast, accurate and standardized method for parsing and validating FASTA formatted sequence data.

  2. Sensorless Sliding Mode Vector Control of Induction Motor Drives

    OpenAIRE

    Gouichiche Abdelmadjid; Boucherit Mohamed Seghir; Safa Ahmed; Messlem Youcef

    2012-01-01

    In this paper we present the design of sliding mode controllers for sensorless field oriented control of induction motor. In order to improve the performance of controllers, the motor speed is controlled by sliding mode regulator with integral sliding surface. The estimated rotor speed used in speed feedback loop is calculated by an adaptive observer based on MRAS (model reference adaptive system) technique .the validity of the proposed scheme is demonstrated by experimental results.

  3. Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience

    International Nuclear Information System (INIS)

    Wang, Q.; Qin, J.; He, B.; Zhou, Y.; Yang, J.-J.; Hou, X.-L.; Yang, X.-B.; Chen, J.-H.; Chen, Y.-D.

    2013-01-01

    Aim: To evaluate the feasibility of double prospectively electrocardiogram (ECG)-triggered high-pitch spiral acquisition mode (double high-pitch mode) for coronary computed tomography angiography (CTCA). Materials and methods: One hundred and forty-nine consecutive patients [40 women, 109 men; mean age 58.2 ± 9.2 years; sinus rhythm ≤70 beats/min (bpm) after pre-medication, body weight ≤100 kg] were enrolled for CTCA examinations using a dual-source CT system with 2 × 128 × 0.6 mm collimation, 0.28 s rotation time, and a pitch of 3.4. Double high-pitch mode was prospectively triggered first at 60% and later at 30% of the R–R interval within two cardiac cycles. Image quality was evaluated using a four-point scale (1 = excellent, 4 = non-assessable). Results: From 2085 coronary artery segments, 86.4% (1802/2085) were rated as having a score of 1, 12.3% (257/2085) as score of 2, 1.2% (26/2085) as score of 3, and none were rated as “non-assessable”. The average image quality score was 1.15 ± 0.26 on a per-segment basis. The effective dose was calculated by multiplying the coefficient factor of 0.028 by the dose–length product (DLP); the mean effective dose was 3.5 ± 0.8 mSv (range 1.7–7.6 mSv). The total dosage of contrast medium was 78.7 ± 2.9 ml. Conclusion: Double prospectively ECG-triggered high-pitch spiral acquisition mode provides good image quality with an average effective dose of less than 5 mSv in patients with a heart rate ≤70 bpm

  4. Information-dependent acquisition-mediated LC-MS/MS screening procedure with semiquantitative potential.

    Science.gov (United States)

    Decaestecker, Tineke N; Vande Casteele, Sofie R; Wallemacq, Pierre E; Van Peteghem, Carlos H; Defore, Dieter L; Van Bocxlaer, Jan F

    2004-11-01

    The development of a LC-MS/MS general unknown screening procedure for toxicologically relevant substances in blood samples by means of information-dependent acquisition on a Q-TOF is reported. IDA is an artificial intelligence-based product ion scan mode providing automatic "on-the-fly" MS to MS/MS switching. By performing information-dependent scanning at two different fragmentation energies, two collision-induced dissociation product ion spectra for each of the detected compounds are generated. As such, information-rich MS/MS spectra are obtained from precursor ions not known beforehand. In addition, limitation of the MS/MS acquisition time to an acceptable minimum resulted in an almost instantaneous switch back to the MS mode. As such, this approach provided MS chromatograms that still could be of use for semiquantitative purposes. Since the switching intensity threshold, unequivocally related to the background noise, proved a critical parameter, the solid-phase extraction procedure, the liquid chromatographic conditions, and the mass spectrometric parameters all were optimized to the advantage of information-dependent acquisition. Finally, the screening procedure we developed was benchmarked, on one hand, qualitatively against the results obtained from traditional GUS approaches in a number of routine toxicological laboratories (20 samples) and, on the other hand, quantitatively with respect to its potential against established LC-MS/MS methods (7 samples). The procedure performed very well from a qualitative point of view; almost all of the drugs detected by the conventional techniques were identified, as well as additional drugs that were not previously reported. The procedure proved well-suited for an initial semiquantitative assessment, as is customary in, for example, forensic toxicology before accurate intoxication levels are determined using targeted analytical analyses.

  5. Image acquisition and interpretation criteria for {sup 99m}Tc-HMPAO-labelled white blood cell scintigraphy: results of a multicentre study

    Energy Technology Data Exchange (ETDEWEB)

    Erba, Paola A. [University of Pisa Medical School (Italy). Regional Center of Nuclear Medicine; Glaudemans, Andor W.J.M.; Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Veltman, Niels C. [Jeroen Bosch Hospital, ' s-Hertogenbosch (Netherlands). Dept. of Nuclear Medicine; Sollini, Martina [Arcisprdale S. Maria Nuova - IRCCS, Reggio Emilia (Italy). Nuclear Medicine Unit; Pacilio, Marta; Galli, Filippo [Sapienza Univ., Rome (Italy). Nuclear Medicine Unit; Signore, Alberto [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Sapienza Univ., Rome (Italy). Nuclear Medicine Unit; Sapienza Univ., Rome (Italy). Ospedale S. Andrea Medicina Nucleare

    2014-04-15

    There is no consensus yet on the best protocol for planar image acquisition and interpretation of radiolabelled white blood cell (WBC) scintigraphy. This may account for differences in reported diagnostic accuracy amongst different centres. This was a multicentre retrospective study analysing 235 WBC scans divided into two groups. The first group of scans (105 patients) were acquired with a fixed-time acquisition protocol and the second group (130 patients) were acquired with a decay time-corrected acquisition protocol. Planar images were interpreted both qualitatively and semiquantitatively. Three blinded readers analysed the images. The most accurate imaging acquisition protocol comprised image acquisition at 3 - 4 h and at 20 - 24 h in time mode with acquisition times corrected for isotope decay. Using this protocol, visual analysis had high sensitivity and specificity in the diagnosis of infection. Semiquantitative analysis could be used in doubtful cases, with no cut-off for the percentage increase in radiolabelled WBC over time, as a criterion to define a positive scan. (orig.)

  6. Identifying Enterprise Leverage Points in Defense Acquisition Program Performance

    Science.gov (United States)

    2009-09-01

    differentiated . [108] Table 1: Table of Validation and Approval Authority5 Beyond the major categories used for programs as noted above, there is also a...impossible to identify which “ uber -portfolio” a system should belong to as many “portfolios” claim a system as an integral part of the larger portfolio...to differentiate between programs. DOD 5002, Enclosure E states “A technology project or acquisition program shall be categorized based on its

  7. Mergers and Acquisitions

    OpenAIRE

    Frasch, Manfred; Leptin, Maria

    2000-01-01

    Mergers and acquisitions (M&As) are booming a strategy of choice for organizations attempting to maintain a competitive advantage. Previous research on mergers and acquisitions declares that acquirers do not normally benefit from acquisitions. Targets, on the other hand, have a tendency of gaining positive returns in the few days surrounding merger announcements due to several characteristic on the acquisitions deal. The announcement period wealth effect on acquiring firms, however, is as cle...

  8. A research of a high precision multichannel data acquisition system

    Science.gov (United States)

    Zhong, Ling-na; Tang, Xiao-ping; Yan, Wei

    2013-08-01

    The output signals of the focusing system in lithography are analog. To convert the analog signals into digital ones which are more flexible and stable to process, a desirable data acquisition system is required. The resolution of data acquisition, to some extent, affects the accuracy of focusing. In this article, we first compared performance between the various kinds of analog-to-digital converters (ADC) available on the market at the moment. Combined with the specific requirements (sampling frequency, converting accuracy, numbers of channels etc) and the characteristics (polarization, amplitude range etc) of the analog signals, the model of the ADC to be used as the core chip in our hardware design was determined. On this basis, we chose other chips needed in the hardware circuit that would well match with ADC, then the overall hardware design was obtained. Validation of our data acquisition system was verified through experiments and it can be demonstrated that the system can effectively realize the high resolution conversion of the multi-channel analog signals and give the accurate focusing information in lithography.

  9. Topological field theory: zero-modes and renormalization

    International Nuclear Information System (INIS)

    Ouvry, S.; Thompson, G.

    1989-09-01

    We address the issue of the non-triviality of the observables in various Topological Field Theories by means of the explicit introduction of the zero-modes into the BRST algebra. Supersymmetric quantum mechanics and Topological Yang-Mills theory are dealt with in detail. It is shown that due to the presence of fermionic zero-modes the BRST algebra may be dynamically broken leading to non trivial observables albeit the local cohomology being trivial. However the metric and coupling constant independence of the observables are still valid. A renormalization procedure is given that correctly incorporates the zero-modes. Particular attention is given to the conventional gauge fixing in Topological Yang-Mills theories, with emphasis on the geometrical character of the fields and their role in the non-triviality of the observables

  10. Optimization and experimental validation of stiff porous phononic plates for widest complete bandgap of mixed fundamental guided wave modes

    Science.gov (United States)

    Hedayatrasa, Saeid; Kersemans, Mathias; Abhary, Kazem; Uddin, Mohammad; Van Paepegem, Wim

    2018-01-01

    Phononic crystal plates (PhPs) have promising application in manipulation of guided waves for design of low-loss acoustic devices and built-in acoustic metamaterial lenses in plate structures. The prominent feature of phononic crystals is the existence of frequency bandgaps over which the waves are stopped, or are resonated and guided within appropriate defects. Therefore, maximized bandgaps of PhPs are desirable to enhance their phononic controllability. Porous PhPs produced through perforation of a uniform background plate, in which the porous interfaces act as strong reflectors of wave energy, are relatively easy to produce. However, the research in optimization of porous PhPs and experimental validation of achieved topologies has been very limited and particularly focused on bandgaps of flexural (asymmetric) wave modes. In this paper, porous PhPs are optimized through an efficient multiobjective genetic algorithm for widest complete bandgap of mixed fundamental guided wave modes (symmetric and asymmetric) and maximized stiffness. The Pareto front of optimization is analyzed and variation of bandgap efficiency with respect to stiffness is presented for various optimized topologies. Selected optimized topologies from the stiff and compliant regimes of Pareto front are manufactured by water-jetting an aluminum plate and their promising bandgap efficiency is experimentally observed. An optimized Pareto topology is also chosen and manufactured by laser cutting a Plexiglas (PMMA) plate, and its performance in self-collimation and focusing of guided waves is verified as compared to calculated dispersion properties.

  11. The composing technique of fast and large scale nuclear data acquisition and control system with single chip microcomputers and PC computers

    International Nuclear Information System (INIS)

    Xu Zurun; Wu Shiying; Liu Haitao; Yao Yangsen; Wang Yingguan; Yang Chaowen

    1998-01-01

    The technique of employing single-chip microcomputers and PC computers to compose a fast and large scale nuclear data acquisition and control system was discussed in detail. The optimum composition mode of this kind of system, the acquisition and control circuit unit based on single-chip microcomputers, the real-time communication methods and the software composition under the Windows 3.2 were also described. One, two and three dimensional spectra measured by this system were demonstrated

  12. The composing technique of fast and large scale nuclear data acquisition and control system with single chip microcomputers and PC computers

    International Nuclear Information System (INIS)

    Xu Zurun; Wu Shiying; Liu Haitao; Yao Yangsen; Wang Yingguan; Yang Chaowen

    1997-01-01

    The technique of employing single-chip microcomputers and PC computers to compose a fast and large scale nuclear data acquisition and control system was discussed in detail. The optimum composition mode of this kind of system, the acquisition and control circuit unit based on single-chip microcomputers, the real-time communication methods and the software composition under the Windows 3.2 were also described. One, two and three dimensional spectra measured by this system were demonstrated

  13. Predicting the ungauged basin : Model validation and realism assessment

    NARCIS (Netherlands)

    Van Emmerik, T.H.M.; Mulder, G.; Eilander, D.; Piet, M.; Savenije, H.H.G.

    2015-01-01

    The hydrological decade on Predictions in Ungauged Basins (PUB) led to many new insights in model development, calibration strategies, data acquisition and uncertainty analysis. Due to a limited amount of published studies on genuinely ungauged basins, model validation and realism assessment of

  14. Predicting the ungauged basin: model validation and realism assessment

    NARCIS (Netherlands)

    van Emmerik, Tim; Mulder, Gert; Eilander, Dirk; Piet, Marijn; Savenije, Hubert

    2015-01-01

    The hydrological decade on Predictions in Ungauged Basins (PUB) led to many new insights in model development, calibration strategies, data acquisition and uncertainty analysis. Due to a limited amount of published studies on genuinely ungauged basins, model validation and realism assessment of

  15. Microprocessor-controlled data-acquisition instrument for neutron-activation measurements

    International Nuclear Information System (INIS)

    Jones, B.A.

    1981-01-01

    This paper describes a microprocessor controlled data acquisition instrument designed at Lawrence Livermore National Laboratory to provide experimenters with a diagnostic tool for measuring the performance of laser imploded fusion targets via neutron activation techniques. This instrument features the ability to count four independent inputs simultaneously while providing a front panel readout of these inputs, plus a time of day clock. A hardcopy printout of the data is also provided by a built-in thermal printer. All running modes and parameters are user selectable via a front panel keypad, and a complete set of internal self-testing diagnostics are available for debug

  16. Modes of acquisition of health literacy skills in informal learning contexts.

    Science.gov (United States)

    Calha, António Geraldo Manso

    2014-12-01

    In this article we try to analyze the learning processes of health literacy skills in informal contexts. We intend to broaden the understanding of the learning process beyond the formal contexts, thus contributing to the elucidation of health professionals on how individuals acquire and manage their knowledge in health matters. Given our goal, we use an analytic corpus constituted by one hundred autobiographical narratives written between 2006 and 2011, in educational contexts but with recognized potential for use in different scientific fields, including health. The results reveal the existence of three different types of modes of learning health literacy skills in informal context: : i) learning that takes place in action, in achieving daily tasks; ii) learning processes that result from problem solving; iii) learning that occurs in an unplanned manner, resulting from accidental circumstances and, in some cases, devoid of intentionality.

  17. Coupled-Mode Theory for Complex-Index, Corrugated Multilayer Stacks

    DEFF Research Database (Denmark)

    Lüder, Hannes; Gerken, Martina; Adam, Jost

    , and by choosing a bi-orthogonal basis, obtained by solving the corresponding adjoint problem. With the once found modal solutions of the unperturbed waveguide, we can calculate the coupling coefficients, which describe the mode coupling caused by the introduced periodic corrugation. [1] C. Kluge et al., Opt......We present a coupled-mode theory (CMT) approach for modelling the modal behaviour of multi- layer thinfilm devices with complex material parameters and periodic corrugations. Our method provides fast computation and extended physical insight as compared to standard numerical methods...... to be non-Hermitian, introducing two major consequences. First, the eigenvalues (i. e. the mode neff) have to be found in the complex plane (Fig. 2). Second, the classical mode orthogonality is no longer valid. We address both challenges by a combination of three complex-root solving algorithms...

  18. Mergers and Acquisitions

    DEFF Research Database (Denmark)

    Risberg, Annette

    Introduction to the study of mergers and acquisitions. This book provides an understanding of the mergers and acquisitions process, how and why they occur, and also the broader implications for organizations. It presents issues including motives and planning, partner selection, integration......, employee experiences and communication. Mergers and acquisitions remain one of the most common forms of growth, yet they present considerable challenges for the companies and management involved. The effects on stakeholders, including shareholders, managers and employees, must be considered as well...... by editorial commentaries and reflects the important organizational and behavioural aspects which have often been ignored in the past. By providing this in-depth understanding of the mergers and acquisitions process, the reader understands not only how and why mergers and acquisitions occur, but also...

  19. Data acquisition electronics for gamma ray emission tomography using width-modulated leading-edge discriminators

    Energy Technology Data Exchange (ETDEWEB)

    Lage, E; Tapias, G; Villena, J; Desco, M; Vaquero, J J, E-mail: desco@mce.hggm.e [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain)

    2010-08-07

    We present a new high-performance and low-cost approach for implementing radiation detection acquisition systems. The basic elements used are charge-integrating ADCs and a set of components encapsulated in an HDL (hardware definition language) library which makes it possible to implement several acquisition tasks such as time pickoff and coincidence detection using a new and simple trigger technique that we name WMLET (width-modulated leading-edge timing). As proof of concept, a 32-channel hybrid PET/SPECT acquisition system based on these elements was developed and tested. This demonstrator consists of a master module responsible for the generation and distribution of trigger signals, 2 x 16-channel ADC cards (12-bit resolution) for data digitization and a 32-bit digital I/O PCI card for handling data transmission to a personal computer. System characteristics such as linearity, maximum transmission rates or timing resolution in coincidence mode were evaluated with test and real detector signals. Imaging capabilities of the prototype were also evaluated using different detector configurations. The performance tests showed that this implementation is able to handle data rates in excess of 600k events s{sup -1} when acquiring simultaneously 32 channels (96-byte events). ADC channel linearity is >98.5% in energy quantification. Time resolution in PET mode for the tested configurations ranges from 3.64 ns FWHM to 7.88 ns FWHM when signals from LYSO-based detectors are used. The measured energy resolution matched the expected values for the detectors evaluated and single elements of crystal matrices can be neatly separated in the acquired flood histograms.

  20. Data acquisition electronics for gamma ray emission tomography using width-modulated leading-edge discriminators

    Science.gov (United States)

    Lage, E.; Tapias, G.; Villena, J.; Desco, M.; Vaquero, J. J.

    2010-08-01

    We present a new high-performance and low-cost approach for implementing radiation detection acquisition systems. The basic elements used are charge-integrating ADCs and a set of components encapsulated in an HDL (hardware definition language) library which makes it possible to implement several acquisition tasks such as time pickoff and coincidence detection using a new and simple trigger technique that we name WMLET (width-modulated leading-edge timing). As proof of concept, a 32-channel hybrid PET/SPECT acquisition system based on these elements was developed and tested. This demonstrator consists of a master module responsible for the generation and distribution of trigger signals, 2 × 16-channel ADC cards (12-bit resolution) for data digitization and a 32-bit digital I/O PCI card for handling data transmission to a personal computer. System characteristics such as linearity, maximum transmission rates or timing resolution in coincidence mode were evaluated with test and real detector signals. Imaging capabilities of the prototype were also evaluated using different detector configurations. The performance tests showed that this implementation is able to handle data rates in excess of 600k events s-1 when acquiring simultaneously 32 channels (96-byte events). ADC channel linearity is >98.5% in energy quantification. Time resolution in PET mode for the tested configurations ranges from 3.64 ns FWHM to 7.88 ns FWHM when signals from LYSO-based detectors are used. The measured energy resolution matched the expected values for the detectors evaluated and single elements of crystal matrices can be neatly separated in the acquired flood histograms.

  1. Fast image acquisition and processing on a TV camera-based portal imaging system

    International Nuclear Information System (INIS)

    Baier, K.; Meyer, J.

    2005-01-01

    The present paper describes the fast acquisition and processing of portal images directly from a TV camera-based portal imaging device (Siemens Beamview Plus trademark). This approach employs not only hard- and software included in the standard package installed by the manufacturer (in particular the frame grabber card and the Matrox(tm) Intellicam interpreter software), but also a software tool developed in-house for further processing and analysis of the images. The technical details are presented, including the source code for the Matrox trademark interpreter script that enables the image capturing process. With this method it is possible to obtain raw images directly from the frame grabber card at an acquisition rate of 15 images per second. The original configuration by the manufacturer allows the acquisition of only a few images over the course of a treatment session. The approach has a wide range of applications, such as quality assurance (QA) of the radiation beam, real-time imaging, real-time verification of intensity-modulated radiation therapy (IMRT) fields, and generation of movies of the radiation field (fluoroscopy mode). (orig.)

  2. A data acquisition work station for ORELA [Oak Ridge Electron Linear Accelerator

    International Nuclear Information System (INIS)

    Rooney, B.D.; Todd, J.H.; Spencer, R.R.; Weston, L.W.

    1990-09-01

    A new multiparameter data acquisition system has been developed and fabricated at the Oak Ridge Electron Linear Accelerator (ORELA) which utilizes an IBM PS/2 Model 80 personal computer and data handler with a 2048 word buffer. The acquisition system can simultaneously acquire data from one, two, or three digitizers, multiplex up to four detectors, read and control up to 16 scalers, and output 32 DC logic signals which can be used to control external instrumentation. Software has been developed for the OS/2 operating system, supporting multiparameter data storage for up to three million channels with the capability of collecting data in a background mode, to make the computer available for other tasks while collecting data. The system also supports multiparameter biasing and can collect, crunch, and store data at rates as high as 30,000 events per second

  3. Development and validation of a multi-residue method for the detection of a wide range of hormonal anabolic compounds in hair using gas chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Rambaud, Lauriane; Monteau, Fabrice; Deceuninck, Yoann; Bichon, Emmanuelle; Andre, Francois; Le Bizec, Bruno

    2007-01-01

    The monitoring of anabolic steroid residues in hair is undoubtedly one of the most efficient strategies to demonstrate the long-term administration of these molecules in meat production animals. A multi-residue sample preparation procedure was developed and validated for 28 steroids. A 100 mg hair sample was grinded into powder and extracted at 50 deg. C with methanol. After acidic hydrolysis and extraction with ethyl acetate, phenolsteroids, such as estrogens, resorcyclic acid lactones and stilbens in one hand, are separated from androgens and progestagens in the other hand. Solid phase extractions were performed before applying a specific derivatisation for each compound sub-group. Detection and identification were achieved using gas chromatography-tandem mass spectrometry with acquisition in the selected reaction monitoring mode after electron ionisation. The method was validated according to the 2002/657/EC guideline. Decision limits (CCα) for main steroids were in the 0.1-10 μg kg -1 range

  4. Development and validation of a multi-residue method for the detection of a wide range of hormonal anabolic compounds in hair using gas chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rambaud, Lauriane [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Monteau, Fabrice [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Deceuninck, Yoann [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Bichon, Emmanuelle [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Andre, Francois [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Le Bizec, Bruno [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France)]. E-mail: lebizec@vet-nantes.fr

    2007-03-14

    The monitoring of anabolic steroid residues in hair is undoubtedly one of the most efficient strategies to demonstrate the long-term administration of these molecules in meat production animals. A multi-residue sample preparation procedure was developed and validated for 28 steroids. A 100 mg hair sample was grinded into powder and extracted at 50 deg. C with methanol. After acidic hydrolysis and extraction with ethyl acetate, phenolsteroids, such as estrogens, resorcyclic acid lactones and stilbens in one hand, are separated from androgens and progestagens in the other hand. Solid phase extractions were performed before applying a specific derivatisation for each compound sub-group. Detection and identification were achieved using gas chromatography-tandem mass spectrometry with acquisition in the selected reaction monitoring mode after electron ionisation. The method was validated according to the 2002/657/EC guideline. Decision limits (CC{alpha}) for main steroids were in the 0.1-10 {mu}g kg{sup -1} range.

  5. The Relative Effects of Explicit Correction and Recasts on Two Target Structures via Two Communication Modes

    Science.gov (United States)

    Yilmaz, Yucel

    2012-01-01

    This study investigated the effects of negative feedback type (i.e., explicit correction vs. recasts), communication mode (i.e., face-to-face communication vs. synchronous computer-mediated communication), and target structure salience (i.e., salient vs. nonsalient) on the acquisition of two Turkish morphemes. Forty-eight native speakers of…

  6. Ecological Validity in Eye-Tracking: An Empirical Study

    Science.gov (United States)

    Spinner, Patti; Gass, Susan M.; Behney, Jennifer

    2013-01-01

    Eye-trackers are becoming increasingly widespread as a tool to investigate second language (L2) acquisition. Unfortunately, clear standards for methodology--including font size, font type, and placement of interest areas--are not yet available. Although many researchers stress the need for ecological validity--that is, the simulation of natural…

  7. Coupled modes, frequencies and fields of a dielectric resonator and a cavity using coupled mode theory

    Science.gov (United States)

    Elnaggar, Sameh Y.; Tervo, Richard; Mattar, Saba M.

    2014-01-01

    Probes consisting of a dielectric resonator (DR) inserted in a cavity are important integral components of electron paramagnetic resonance (EPR) spectrometers because of their high signal-to-noise ratio. This article studies the behavior of this system, based on the coupling between its dielectric and cavity modes. Coupled-mode theory (CMT) is used to determine the frequencies and electromagnetic fields of this coupled system. General expressions for the frequencies and field distributions are derived for both the resulting symmetric and anti-symmetric modes. These expressions are applicable to a wide range of frequencies (from MHz to THz). The coupling of cavities and DRs of various sizes and their resonant frequencies are studied in detail. Since the DR is situated within the cavity then the coupling between them is strong. In some cases the coupling coefficient, κ, is found to be as high as 0.4 even though the frequency difference between the uncoupled modes is large. This is directly attributed to the strong overlap between the fields of the uncoupled DR and cavity modes. In most cases, this improves the signal to noise ratio of the spectrometer. When the DR and the cavity have the same frequency, the coupled electromagnetic fields are found to contain equal contributions from the fields of the two uncoupled modes. This situation is ideal for the excitation of the probe through an iris on the cavity wall. To verify and validate the results, finite element simulations are carried out. This is achieved by simulating the coupling between a cylindrical cavity's TE011 and the dielectric insert's TE01δ modes. Coupling between the modes of higher order is also investigated and discussed. Based on CMT, closed form expressions for the fields of the coupled system are proposed. These expressions are crucial in the analysis of the probe's performance.

  8. Modes of acquisition of health literacy skills in informal learning contexts

    Directory of Open Access Journals (Sweden)

    António Geraldo Manso Calha

    2014-12-01

    Full Text Available In this article we try to analyze the learning processes of health literacy skills in informal contexts. We intend to broaden the understanding of the learning process beyond the formal contexts, thus contributing to the elucidation of health professionals on how individuals acquire and manage their knowledge in health matters. Given our goal, we use an analytic corpus constituted by one hundred autobiographical narratives written between 2006 and 2011, in educational contexts but with recognized potential for use in different scientific fields, including health. The results reveal the existence of three different types of modes of learning health literacy skills in informal context: : i learning that takes place in action, in achieving daily tasks; ii learning processes that result from problem solving; iii learning that occurs in an unplanned manner, resulting from accidental circumstances and, in some cases, devoid of intentionality.

  9. A new DoD initiative: the Computational Research and Engineering Acquisition Tools and Environments (CREATE) program

    International Nuclear Information System (INIS)

    Arevalo, S; Atwood, C; Bell, P; Blacker, T D; Dey, S; Fisher, D; Fisher, D A; Genalis, P; Gorski, J; Harris, A; Hill, K; Hurwitz, M; Kendall, R P; Meakin, R L; Morton, S; Moyer, E T; Post, D E; Strawn, R; Veldhuizen, D v; Votta, L G

    2008-01-01

    In FY2008, the U.S. Department of Defense (DoD) initiated the Computational Research and Engineering Acquisition Tools and Environments (CREATE) program, a $360M program with a two-year planning phase and a ten-year execution phase. CREATE will develop and deploy three computational engineering tool sets for DoD acquisition programs to use to design aircraft, ships and radio-frequency antennas. The planning and execution of CREATE are based on the 'lessons learned' from case studies of large-scale computational science and engineering projects. The case studies stress the importance of a stable, close-knit development team; a focus on customer needs and requirements; verification and validation; flexible and agile planning, management, and development processes; risk management; realistic schedules and resource levels; balanced short- and long-term goals and deliverables; and stable, long-term support by the program sponsor. Since it began in FY2008, the CREATE program has built a team and project structure, developed requirements and begun validating them, identified candidate products, established initial connections with the acquisition programs, begun detailed project planning and development, and generated the initial collaboration infrastructure necessary for success by its multi-institutional, multidisciplinary teams

  10. Microprocessor based data acquisition system for Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Patwardhan, P.K.; Indurkar, V.S.

    1981-01-01

    A data acquisition system, for Moessbauer spectrometer and other probability distribution spectrum is described. This utilizes the advantages of incorporating a microcomputer for providing a flexible analytical capability and speed of hard wired MCS unit updating channel contents in DMA. Holbourn, Player and Woodhams have recently described a microprocessor controlled Moessbauer spectrometer where microprocessor performs the task of updating channel contents, requiring about 60 micro seconds in interrupt mode. This imposes restrictions on increasing the channel number and on increasing the velocity scan frequency in order to cover higher velocity ranges. The system described in this article performs data acquisition in faster direct memory access. It is a two module system, (1) MCS module (2) Microcomputer module, arranged around a common address, data and control buses. The microcomputer module has an access to the system data during flyback periods and can be programmed for the task of monitor on progess of experiment and as a manipulator of various control operations needed during experiment. The system firmware includes: (1) MONITOR (2) BLOCK-TRANSFER (3) DATA-SMOOTHING (4) DECIMAL-CONVERTER (5) MATH. The scope of this firmware is briefly described. (author)

  11. Towards automated diffraction tomography: Part I-Data acquisition

    International Nuclear Information System (INIS)

    Kolb, U.; Gorelik, T.; Kuebel, C.; Otten, M.T.; Hubert, D.

    2007-01-01

    The ultimate aim of electron diffraction data collection for structure analysis is to sample the reciprocal space as accurately as possible to obtain a high-quality data set for crystal structure determination. Besides a more precise lattice parameter determination, fine sampling is expected to deliver superior data on reflection intensities, which is crucial for subsequent structure analysis. Traditionally, three-dimensional (3D) diffraction data are collected by manually tilting a crystal around a selected crystallographic axis and recording a set of diffraction patterns (a tilt series) at various crystallographic zones. In a second step, diffraction data from these zones are combined into a 3D data set and analyzed to yield the desired structure information. Data collection can also be performed automatically, with the recent advances in tomography acquisition providing a suitable basis. An experimental software module has been developed for the Tecnai microscope for such an automated diffraction pattern collection while tilting around the goniometer axis. The module combines STEM imaging with diffraction pattern acquisition in nanodiffraction mode. It allows automated recording of diffraction tilt series from nanoparticles with a size down to 5 nm

  12. Microstructurally Based Prediction of High Strain Failure Modes in Crystalline Solids

    Science.gov (United States)

    2016-07-05

    interfaces in hcp– fcc systems subjected to high strain-rate deformation and fracture modes, Journal of Materials Research, (8 2015): 0. doi: 10.1557/jmr...rupture • Comparison and validation with experimental observations/ measurements • New dislocation-density crystalline plasticity that accounts for...relationships between coherent interfaces in hcp– fcc systems subjected to high strain-rate deformation and fracture modes, Journal of Materials Research, Vol. 30

  13. Acceleration of FDTD mode solver by high-performance computing techniques.

    Science.gov (United States)

    Han, Lin; Xi, Yanping; Huang, Wei-Ping

    2010-06-21

    A two-dimensional (2D) compact finite-difference time-domain (FDTD) mode solver is developed based on wave equation formalism in combination with the matrix pencil method (MPM). The method is validated for calculation of both real guided and complex leaky modes of typical optical waveguides against the bench-mark finite-difference (FD) eigen mode solver. By taking advantage of the inherent parallel nature of the FDTD algorithm, the mode solver is implemented on graphics processing units (GPUs) using the compute unified device architecture (CUDA). It is demonstrated that the high-performance computing technique leads to significant acceleration of the FDTD mode solver with more than 30 times improvement in computational efficiency in comparison with the conventional FDTD mode solver running on CPU of a standard desktop computer. The computational efficiency of the accelerated FDTD method is in the same order of magnitude of the standard finite-difference eigen mode solver and yet require much less memory (e.g., less than 10%). Therefore, the new method may serve as an efficient, accurate and robust tool for mode calculation of optical waveguides even when the conventional eigen value mode solvers are no longer applicable due to memory limitation.

  14. Efficient design and operation of a data acquisition system for pressurized pipeline systems.

    Science.gov (United States)

    Kim, S

    2006-01-01

    The unsteady flow analysis of pipeline systems provides useful guidelines for implementing data acquisition components such as data filtering ranges, sensor locations and sampling frequencies. A theoretical integration among hydraulics, free vibration analysis and signal processing is proposed for a comprehensive approach aiming at enhanced design and operation of data acquisition system. Transient analysis is performed to extract flow variation by a valve modulation in a pipeline system. Frequency transformation analysis is developed to convert pressure variations between time domain and frequency domain. Free vibration analysis provides spatial distribution of impedance characteristics and pressure variation for determining optimum sensor location. A real-time filter can be designed to secure valid signals of any particular unsteady event. Hypothetical and experimental applications show that the proposed method has potentials of the leakage detection of a pipeline system as well as an efficient design of data acquisition system.

  15. Absorption and emission from mode conversion theory

    International Nuclear Information System (INIS)

    Swanson, D.G.

    1995-02-01

    The effects of mode conversion theory on emission have led to some surprising results. The classical expressions were originally derived from models which did not include mode conversion or its attendant reflection. When mode conversion was included, the first surprise was that the transmission coefficient is totally independent of absorption and due exclusively to tunneling. The other surprise is that the observed emission arises from two distinct sources, one direct, and one from an indirect Bernstein wave source which is partially converted in the cyclotron layer to outgoing electromagnetic waves, with the net result that mode conversion cancels out for the electron case. The only corrections to electron cyclotron emission are then due to reflection effects, and these have been shown to be small for laboratory plasmas, leading to the validation of the classical formula, but via an entirely new paradigm in its interpretation. This paper includes a summary of the absorption process for electron cyclotron harmonics, and reviews the emission physics, including both potential error estimates and a discussion of the spatial emission source distribution

  16. Telemetry Standards, RCC Standard 106-17. Chapter 8. Digital Data Bus Acquisition Formatting Standard

    Science.gov (United States)

    2017-07-01

    incorrect word count/message and illegal mode codes are not considered bus errors. 8.6.2 Source Signal The source of data is a signal conforming to...Telemetry Standards, RCC Standard 106-17 Chapter 8, July 2017 CHAPTER 8 Digital Data Bus Acquisition Formatting Standard Acronyms...check FCS frame check sequence HDDR high-density digital recording MIL-STD Military Standard msb most significant bit PCM pulse code modulation

  17. Felicity Conditions for Human Skill Acquisition: Validating an AI (Artificial Intelligence)-Based Theory.

    Science.gov (United States)

    1983-11-01

    B1 /SHOW2 1/BORROW 2/BORROW 1/SHOW X/OVRWRT W/OVRWRT Figure 2-12...34,,** ’% ".."’ ’ ° ’ . . . . " " *, . . " " . " ". .". , . • " . " . ., ’ -". ,""" ’" - . , ’ ’. " FETcHi PATTERNS 229 V,., *AC1:AC LC:A C1 :COL A1 :BLK C2:COL A2:BLK T1DIG T B1 T2:DIGIT...Glen Bryan ERIC Facility-Acquisitions . Dr. Edward C. Weiss 6208 Poe Road 4833 Rugby Avenue National Science Foundation Bethesda, MD 20817 Bethesda.

  18. Experimental data and boundary conditions for a Double-Skin Facade building in external air curtain mode

    DEFF Research Database (Denmark)

    Larsen, Olena Kalyanova; Heiselberg, Per; Jensen, Rasmus Lund

    Frequent discussions of double skin façade energy performance have started a dialogue about the methods, models and tools for simulation of double façade systems and reliability of their results. Their reliability will increase with empirical validation of the software. Detailed experimental work...... was carried out in a full scale test facility ‘The Cube’, in order to compile three sets of high quality experimental data for validation purposes. The data sets are available for preheating mode, external air curtain mode and transparent insulation mode. The objective of this article is to provide the reader......’. This covers such problem areas as measurements of naturally induced air flow, measurements of air temperature under direct solar radiation exposure, etc. Finally, in order to create a solid foundation for software validation, the uncertainty and limitations in the experimental results are discussed. In part...

  19. 2017 NAIP Acquisition Map

    Data.gov (United States)

    Farm Service Agency, Department of Agriculture — Planned States for 2017 NAIP acquisition and acquisition status layer (updated daily). Updates to the acquisition seasons may be made during the season to...

  20. A Web-Remote/Robotic/Scheduled Astronomical Data Acquisition System

    Science.gov (United States)

    Denny, Robert

    2011-03-01

    Traditionally, remote/robotic observatory operating systems have been custom made for each observatory. While data reduction pipelines need to be tailored for each investigation, the data acquisition process (especially for stare-mode optical images) is often quite similar across investigations. Since 1999, DC-3 Dreams has focused on providing and supporting a remote/robotic observatory operating system which can be adapted to a wide variety of physical hardware and optics while achieving the highest practical observing efficiency and safe/secure web browser user controls. ACP Expert consists of three main subsystems: (1) a robotic list-driven data acquisition engine which controls all aspects of the observatory, (2) a constraint-driven dispatch scheduler with a long-term database of requests, and (3) a built-in "zero admin" web server and dynamic web pages which provide a remote capability for immediate execution and monitoring as well as entry and monitoring of dispatch-scheduled observing requests. No remote desktop login is necessary for observing, thus keeping the system safe and consistent. All routine operation is via the web browser. A wide variety of telescope mounts, CCD imagers, guiding sensors, filter selectors, focusers, instrument-package rotators, weather sensors, and dome control systems are supported via the ASCOM standardized device driver architecture. The system is most commonly employed on commercial 1-meter and smaller observatories used by universities and advanced amateurs for both science and art. One current project, the AAVSO Photometric All-Sky Survey (APASS), uses ACP Expert to acquire large volumes of data in dispatch-scheduled mode. In its first 18 months of operation (North then South), 40,307 sky images were acquired in 117 photometric nights, resulting in 12,107,135 stars detected two or more times. These stars had measures in 5 filters. The northern station covered 754 fields (6446 square degrees) at least twice, the southern

  1. Supervisory Control and Data Acquisition Laboratory

    Directory of Open Access Journals (Sweden)

    M. Iacob

    2010-06-01

    Full Text Available This paper presents practical laboratories for teaching purpose in Supervisory Control and Data Acquisition (SCADA systems. A SCADA system is described in terms of architecture, process interfaces, functionality, and application development facilities. These concepts are implemented on an integrated automation system, particularly for digital control of electric drives with a distributed peripheral, i.e., Totally Integrated Automation with Democase from Siemens. Using this system, a wide range of applications can be designed, implemented and tested. A practical labs set is presented to introduce gradually the main SCADA elements, and finally to develop an application to control an induction motor in interlocked manual/automatic mode, with touch-screen Human Machine Interface (HMI. The system employs industrial busses like PROFIBus and industrial Ethernet. The SCADA system also shows trends, alarms, motor frequency and automatic sequence of motor speed profile.

  2. Development and Integration of a Data Acquisition System for SST-1 Phase-1 Plasma Diagnostics

    International Nuclear Information System (INIS)

    Srivastava, Amit K; Sharma, Manika; Mansuri, Imran; Sharma, Atish; Raval, Tushar; Pradhan, Subrata

    2012-01-01

    Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data

  3. Data acquisition

    International Nuclear Information System (INIS)

    Clout, P.N.

    1982-01-01

    Data acquisition systems are discussed for molecular biology experiments using synchrotron radiation sources. The data acquisition system requirements are considered. The components of the solution are described including hardwired solutions and computer-based solutions. Finally, the considerations for the choice of the computer-based solution are outlined. (U.K.)

  4. Experimental validation of a three-dimensional linear system model for breast tomosynthesis

    International Nuclear Information System (INIS)

    Zhao Bo; Zhou Jun; Hu Yuehoung; Mertelmeier, Thomas; Ludwig, Jasmina; Zhao Wei

    2009-01-01

    A three-dimensional (3D) linear model for digital breast tomosynthesis (DBT) was developed to investigate the effects of different imaging system parameters on the reconstructed image quality. In the present work, experimental validation of the model was performed on a prototype DBT system equipped with an amorphous selenium (a-Se) digital mammography detector and filtered backprojection (FBP) reconstruction methods. The detector can be operated in either full resolution with 85 μm pixel size or 2x1 pixel binning mode to reduce acquisition time. Twenty-five projection images were acquired with a nominal angular range of ±20 deg. The images were reconstructed using a slice thickness of 1 mm with 0.085x0.085 mm in-plane pixel dimension. The imaging performance was characterized by spatial frequency-dependent parameters including a 3D noise power spectrum (NPS) and in-plane modulation transfer function (MTF). Scatter-free uniform x-ray images were acquired at four different exposure levels for noise analysis. An aluminum (Al) edge phantom with 0.2 mm thickness was imaged to measure the in-plane presampling MTF. The measured in-plane MTF and 3D NPS were both in good agreement with the model. The dependence of DBT image quality on reconstruction filters was investigated. It was found that the slice thickness (ST) filter, a Hanning window to limit the high-frequency components in the slice thickness direction, reduces noise aliasing and improves 3D DQE. An ACR phantom was imaged to investigate the effects of angular range and detector operational modes on reconstructed image quality. It was found that increasing the angular range improves the MTF at low frequencies, resulting in better detection of large-area, low-contrast mass lesions in the phantom. There is a trade-off between noise and resolution for pixel binning and full resolution modes, and the choice of detector mode will depend on radiation dose and the targeted lesion.

  5. Experimental validation of a three-dimensional linear system model for breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Bo; Zhou Jun; Hu Yuehoung; Mertelmeier, Thomas; Ludwig, Jasmina; Zhao Wei [Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, New York 11794-8460 (United States); Siemens AG Healthcare, Henkestrasse 127, D-91052 Erlangen (Germany); Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, New York 11794-8460 (United States)

    2009-01-15

    A three-dimensional (3D) linear model for digital breast tomosynthesis (DBT) was developed to investigate the effects of different imaging system parameters on the reconstructed image quality. In the present work, experimental validation of the model was performed on a prototype DBT system equipped with an amorphous selenium (a-Se) digital mammography detector and filtered backprojection (FBP) reconstruction methods. The detector can be operated in either full resolution with 85 {mu}m pixel size or 2x1 pixel binning mode to reduce acquisition time. Twenty-five projection images were acquired with a nominal angular range of {+-}20 deg. The images were reconstructed using a slice thickness of 1 mm with 0.085x0.085 mm in-plane pixel dimension. The imaging performance was characterized by spatial frequency-dependent parameters including a 3D noise power spectrum (NPS) and in-plane modulation transfer function (MTF). Scatter-free uniform x-ray images were acquired at four different exposure levels for noise analysis. An aluminum (Al) edge phantom with 0.2 mm thickness was imaged to measure the in-plane presampling MTF. The measured in-plane MTF and 3D NPS were both in good agreement with the model. The dependence of DBT image quality on reconstruction filters was investigated. It was found that the slice thickness (ST) filter, a Hanning window to limit the high-frequency components in the slice thickness direction, reduces noise aliasing and improves 3D DQE. An ACR phantom was imaged to investigate the effects of angular range and detector operational modes on reconstructed image quality. It was found that increasing the angular range improves the MTF at low frequencies, resulting in better detection of large-area, low-contrast mass lesions in the phantom. There is a trade-off between noise and resolution for pixel binning and full resolution modes, and the choice of detector mode will depend on radiation dose and the targeted lesion.

  6. Ductile mode grinding of reaction-bonded silicon carbide mirrors.

    Science.gov (United States)

    Dong, Zhichao; Cheng, Haobo

    2017-09-10

    The demand for reaction-bonded silicon carbide (RB-SiC) mirrors has escalated recently with the rapid development of space optical remote sensors used in astronomy or Earth observation. However, RB-SiC is difficult to machine due to its high hardness. This study intends to perform ductile mode grinding to RB-SiC, which produces superior surface integrity and fewer subsurface damages, thus minimizing the workload of subsequent lapping and polishing. For this purpose, a modified theoretical model for grain depth of cut of grinding wheels is presented, which correlates various processing parameters and the material characteristics (i.e., elastic module) of a wheel's bonding matrix and workpiece. Ductile mode grinding can be achieved as the grain depth of cut of wheels decreases to be less than the critical cut depth of workpieces. The theoretical model gives a roadmap to optimize the grinding parameters for ductile mode grinding of RB-SiC and other ultra-hard brittle materials. Its feasibility was validated by experiments. With the optimized grinding parameters for RB-SiC, the ductile mode grinding produced highly specular surfaces (with roughness of ∼2.2-2.8  nm Ra), which means the material removal mechanism of RB-SiC is dominated by plastic deformation rather than brittle fracture. Contrast experiments were also conducted on fused silica, using the same grinding parameters; this produced only very rough surfaces, which further validated the feasibility of the proposed model.

  7. A control and data acquisition system for photoelectron spectroscopy experiment station at Hefei National Synchrotron Radiation Laboratory

    International Nuclear Information System (INIS)

    Xu Weimin; Liu Yinim

    1992-01-01

    The paper describes system configuration and software design. The system has the following features; flexible user interface, succinct control levels, strict protection and high intelligence. It can run EDC, CFS, CIS experiment modes very conveniently with SR light source. Its construction and design idea of the system can be applied to other data acquisition systems. (author)

  8. Design and Performance of the Data Acquisition System for the NA61/SHINE Experiment at CERN

    CERN Document Server

    Laszlo, Andras; Fodor, Zoltan; Kiss, Tivadar; Kleinfelder, Stuart; Soos, Csaba; Tefelski, Dariusz; Tolyhi, Tamas; Vesztergombi, Gyorgy; Wyszynski, Oskar

    2015-01-01

    This paper describes the hardware, firmware and software systems used in data acquisition for the NA61/SHINE experiment at the CERN SPS accelerator. Special emphasis is given to the design parameters of the readout electronics for the 40 m^3 volume Time Projection Chamber detectors as these give the largest contribution to event data among all the subdetectors: events consisting of 8 bit ADC values from 256 time slices of 200 k electronic channels are to be read out with order of ~100 Hz readout rate. As the data acquisition system is organized in `push data mode', i.e. local systems transmit data asynchronously, techniques of solving subevent synchronization is also discussed.

  9. Modeling, realization and evaluation of a parallel architecture for the data acquisition in multidetectors

    International Nuclear Information System (INIS)

    Guirande, Ph.; Aleonard, M-M.; Dien, Q-T.; Pedroza, J-L.

    1997-01-01

    The efficiency increasing in four π (EUROGAM, EUROBALL, DIAMANT) is achieved by an increase in the granularity, hence in the event counting rate in the acquisition system. Consequently, an evolution of the architecture of readout systems, coding and software is necessary. To achieve the required evaluation we have implemented a parallel architecture to check the quality of the events. The first application of this architecture was to make available an improved data acquisition system for the DIAMANT multidetector. The data acquisition system of DIAMANT is based on an ensemble of VME cards which must manage: the event readout, their salvation on magnetic support and histogram construction. The ensemble consists of processors distributed in a net, a workstation to control the experiment and a display system for spectra and arrays. In such architecture the task of VME bus becomes quickly a limitation for performances not only for the data transfer but also for coordination of different processors. The parallel architecture used makes the VME bus operation easy. It is based on three DSP C40 (Digital Signal Processor) implanted in a commercial (LSI) VME. It is provided with an external bus used to read the raw data from an interface card (ROCVI) between the 32 bit ECL bus reading the real time VME-based encoders. The performed tests have evidenced jamming after data exchanges between the processors using two communication lines. The analysis of this problem has indicated the necessity of dynamical changes of tasks to avoid this blocking. Intrinsic evaluation (i.e. without transfer on the VME bus) has been carried out for two parallel topologies (processor farm and tree). The simulation software permitted the generation of event packets. The obtained rates are sensibly equivalent (6 Mo/s) independent of topology. The farm topology has been chosen because it is simple to implant. The charge evaluation has reduced the rate in 'simplex' communication mode to 5.3 Mo/s and

  10. Modeling and Validating Time, Buffering, and Utilization of a Large-Scale, Real-Time Data Acquisition System

    CERN Document Server

    AUTHOR|(SzGeCERN)756497; The ATLAS collaboration; Garcia Garcia, Pedro Javier; Vandelli, Wainer; Froening, Holger

    2017-01-01

    Data acquisition systems for large-scale high-energy physics experiments have to handle hundreds of gigabytes per second of data, and are typically realized as specialized data centers that connect a very large number of front-end electronics devices to an event detection and storage system. The design of such systems is often based on many assumptions, small-scale experiments and a substantial amount of over-provisioning. In this work, we introduce a discrete event-based simulation tool that models the data flow of the current ATLAS data acquisition system, with the main goal to be accurate with regard to the main operational characteristics. We measure buffer occupancy counting the number of elements in buffers, resource utilization measuring output bandwidth and counting the number of active processing units, and their time evolution by comparing data over many consecutive and small periods of time. We perform studies on the error of simulation when comparing the results to a large amount of real-world ope...

  11. Modeling and Validating Time, Buffering, and Utilization of a Large-Scale, Real-Time Data Acquisition System

    CERN Document Server

    AUTHOR|(SzGeCERN)756497; The ATLAS collaboration; Garcia Garcia, Pedro Javier; Vandelli, Wainer; Froening, Holger

    2017-01-01

    Data acquisition systems for large-scale high-energy physics experiments have to handle hundreds of gigabytes per second of data, and are typically implemented as specialized data centers that connect a very large number of front-end electronics devices to an event detection and storage system. The design of such systems is often based on many assumptions, small-scale experiments and a substantial amount of over-provisioning. In this paper, we introduce a discrete event-based simulation tool that models the dataflow of the current ATLAS data acquisition system, with the main goal to be accurate with regard to the main operational characteristics. We measure buffer occupancy counting the number of elements in buffers; resource utilization measuring output bandwidth and counting the number of active processing units, and their time evolution by comparing data over many consecutive and small periods of time. We perform studies on the error in simulation when comparing the results to a large amount of real-world ...

  12. Software verification and validation methodology for advanced digital reactor protection system using diverse dual processors to prevent common mode failure

    International Nuclear Information System (INIS)

    Son, Ki Chang; Shin, Hyun Kook; Lee, Nam Hoon; Baek, Seung Min; Kim, Hang Bae

    2001-01-01

    The Advanced Digital Reactor Protection System (ADRPS) with diverse dual processors is being developed by the National Research Lab of KOPEC for ADRPS development. One of the ADRPS goals is to develop digital Plant Protection System (PPS) free of Common Mode Failure (CMF). To prevent CMF, the principle of diversity is applied to both hardware design and software design. For the hardware diversity, two different types of CPUs are used for Bistable Processor and Local Coincidence Logic Processor. The VME based Single Board Computers (SBC) are used for the CPU hardware platforms. The QNX Operating System (OS) and the VxWorks OS are used for software diversity. Rigorous Software Verification and Validation (V and V) is also required to prevent CMF. In this paper, software V and V methodology for the ADRPS is described to enhance the ADRPS software reliability and to assure high quality of the ADRPS software

  13. Global Trends of International Mergers and Acquisitions in the Energy Sector

    Directory of Open Access Journals (Sweden)

    Liubov Galperina

    2017-03-01

    Full Text Available The article explores conditions, factors and results of mergers and acquisitions in international business with the example of the energy industry. The directions of world energy market transformation in the framework of PESTLE analysis have been determined by the factors influencing the efficiency and future of the companies that have effected mergers and acquisitions. The transformation of the global energy market is associated with changes in the main market parameters that affect the sectoral and regional structure of international mergers and acquisitions. Including: growing demand for energy from the growing population of the planet, including due to an increase in the middle class share; fluctuation of world oil market prices; the growth of supply of shale oil changing the transnational flows of trade in primary petroleum products; rising demand for renewable energy as a result of cheapening technologies and diversification policies; the growth of renewable energy sources supply; increase in demand for atomic energy; improvement of energy infrastructure; introduction of energy efficient and low carbon technologies; introduction of safe technologies by energy companies; reduction of transaction costs in power grids due to optimization of modes at application of Smart Grid at all levels (local, on-site, regional, national, international; the expansion of the world-leading countries in the primary energy markets; demonopolization of national energy markets and liberalization of energy markets of the EU, USA, Japan, South Korea, Australia, etc. The world market of mergers and acquisitions has been characterized with the definition of key features of its development. International mergers and acquisitions in the energy sector are analysed on the basis of regional and industry characteristics. The international mergers and acquisitions in the energy sector has been analysed, taking into account the main scenarios for the development of the

  14. Automation and instrument control applied to an experimental study of electron transport dynamics in an avalanche mode resistive plater chamber

    International Nuclear Information System (INIS)

    Ridenti, Marco A.; Pascholati, Paulo R.

    2009-01-01

    In this work it is presented a computer based instrumentation system which was developed to perform data acquisition and integrate the control of different devices in an experimental study of electron transport dynamics in an avalanche mode resistive plate chamber detector in the Radiation Technology Center (CTR) at IPEN/CNEN-SP. System control and data acquisition was performed by a computer program called RPCLabOperator written in MatLab environment running on a LeCroy WavePro 7000 digital oscilloscope. (author)

  15. Investigation of Spiral Bevel Gear Condition Indicator Validation Via AC-29-2C Using Damage Progression Tests

    Science.gov (United States)

    Dempsey, Paula J.

    2014-01-01

    calculated between each CI, component, damage state and torque. Results found test rig and gear design, type of fault and data acquisition can affect CI performance. Results found FM4, SI1 and SI3 can be used to detect macro pitting on two more gear or pinion teeth as long as it is detected prior to progressing to other components or transitioning to another failure mode. The sensitivity of RMS to system and operational conditions limit its reliability for systems that are not maintained at steady state. Failure modes that occurred due to scuffing or fretting were challenging to detect with current gear diagnostic tools, since the damage is distributed across all the gear and pinion teeth, smearing the impacting signatures typically used to differentiate between a healthy and damaged tooth contact. This is one of three final reports published on the results of this project. In the second report, damage modes experienced in the field will be mapped to the failure modes created in the test rig. The helicopter CI data will then be re-processed with the same analysis techniques applied to spiral bevel rig test data. In the third report, results from the rig and helicopter data analysis will be correlated. Observations, findings and lessons learned using sub-scale rig failure progression tests to validate helicopter gear condition indicators will be presented.

  16. A microcontroller-based interface circuit for data acquisition and control of a micromechanical thermal flow sensor

    International Nuclear Information System (INIS)

    Asimakopoulos, P; Kaltsas, G; Nassiopoulou, A G

    2005-01-01

    In the present work, a special microcontroller-based data acquisition and control system was designed and fabricated, for fast and accurate flow measurements with programmable modes of operation. The system can apply predetermined power to the heater and simultaneously is able of monitoring both the thermopile signal and the heater current. An RS232 connection was also implemented for the communication with the outside world. The interface circuit was adapted to the micromechanical flow sensor for evaluation. Various sensor parameters were extracted in both laminar and turbulent flow conditions. The sensor responses with three operation modes (constant voltage, power and temperature) were also obtained

  17. A microcontroller-based interface circuit for data acquisition and control of a micromechanical thermal flow sensor

    Science.gov (United States)

    Asimakopoulos, P.; Kaltsas, G.; Nassiopoulou, A. G.

    2005-01-01

    In the present work, a special microcontroller-based data acquisition and control system was designed and fabricated, for fast and accurate flow measurements with programmable modes of operation. The system can apply predetermined power to the heater and simultaneously is able of monitoring both the thermopile signal and the heater current. An RS232 connection was also implemented for the communication with the outside world. The interface circuit was adapted to the micromechanical flow sensor for evaluation. Various sensor parameters were extracted in both laminar and turbulent flow conditions. The sensor responses with three operation modes (constant voltage, power and temperature) were also obtained.

  18. Development and Validation of a Mobile Device-based External Ventricular Drain Simulator.

    Science.gov (United States)

    Morone, Peter J; Bekelis, Kimon; Root, Brandon K; Singer, Robert J

    2017-10-01

    Multiple external ventricular drain (EVD) simulators have been created, yet their cost, bulky size, and nonreusable components limit their accessibility to residency programs. To create and validate an animated EVD simulator that is accessible on a mobile device. We developed a mobile-based EVD simulator that is compatible with iOS (Apple Inc., Cupertino, California) and Android-based devices (Google, Mountain View, California) and can be downloaded from the Apple App and Google Play Store. Our simulator consists of a learn mode, which teaches users the procedure, and a test mode, which assesses users' procedural knowledge. Twenty-eight participants, who were divided into expert and novice categories, completed the simulator in test mode and answered a postmodule survey. This was graded using a 5-point Likert scale, with 5 representing the highest score. Using the survey results, we assessed the module's face and content validity, whereas construct validity was evaluated by comparing the expert and novice test scores. Participants rated individual survey questions pertaining to face and content validity a median score of 4 out of 5. When comparing test scores, generated by the participants completing the test mode, the experts scored higher than the novices (mean, 71.5; 95% confidence interval, 69.2 to 73.8 vs mean, 48; 95% confidence interval, 44.2 to 51.6; P mobile-based EVD simulator that is inexpensive, reusable, and accessible. Our results demonstrate that this simulator is face, content, and construct valid. Copyright © 2017 by the Congress of Neurological Surgeons

  19. 49 CFR 1522.121 - Security threat assessments for personnel of TSA-approved validation firms.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Security threat assessments for personnel of TSA... FOR ALL MODES OF TRANSPORTATION TSA-APPROVED VALIDATION FIRMS AND VALIDATORS TSA-Approved Validation... for personnel of TSA-approved validation firms. Each of the following must successfully complete a...

  20. Technological Similarity, Post-acquisition R&D Reorganization, and Innovation Performance in Horizontal Acquisition

    DEFF Research Database (Denmark)

    Colombo, Massimo G.; Rabbiosi, Larissa

    2014-01-01

    This paper aims to disentangle the mechanisms through which technological similarity between acquiring and acquired firms influences innovation in horizontal acquisitions. We develop a theoretical model that links technological similarity to: (i) two key aspects of post-acquisition reorganization...... of acquired R&D operations – the rationalization of the R&D operations and the replacement of the R&D top manager, and (ii) two intermediate effects that are closely associated with the post-acquisition innovation performance of the combined firm – improvements in R&D productivity and disruptions in R......&D personnel. We rely on PLS techniques to test our theoretical model using detailed information on 31 horizontal acquisitions in high- and medium-tech industries. Our results indicate that in horizontal acquisitions, technological similarity negatively affects post-acquisition innovation performance...

  1. Implementation of a wireless ECG acquisition SoC for IEEE 802.15.4 (ZigBee) applications.

    Science.gov (United States)

    Wang, Liang-Hung; Chen, Tsung-Yen; Lin, Kuang-Hao; Fang, Qiang; Lee, Shuenn-Yuh

    2015-01-01

    This paper presents a wireless biosignal acquisition system-on-a-chip (WBSA-SoC) specialized for electrocardiogram (ECG) monitoring. The proposed system consists of three subsystems, namely, 1) the ECG acquisition node, 2) the protocol for standard IEEE 802.15.4 ZigBee system, and 3) the RF transmitter circuits. The ZigBee protocol is adopted for wireless communication to achieve high integration, applicability, and portability. A fully integrated CMOS RF front end containing a quadrature voltage-controlled oscillator and a 2.4-GHz low-IF (i.e., zero-IF) transmitter is employed to transmit ECG signals through wireless communication. The low-power WBSA-SoC is implemented by the TSMC 0.18-μm standard CMOS process. An ARM-based displayer with FPGA demodulation and an RF receiver with analog-to-digital mixed-mode circuits are constructed as verification platform to demonstrate the wireless ECG acquisition system. Measurement results on the human body show that the proposed SoC can effectively acquire ECG signals.

  2. A novel camera type for very high energy gamma-ray astronomy based on Geiger-mode avalanche photodiodes

    International Nuclear Information System (INIS)

    Anderhub, H; Biland, A; Boller, A; Braun, I; Commichau, S; Commichau, V; Dorner, D; Gendotti, A; Grimm, O; Gunten, H von; Hildebrand, D; Horisberger, U; Kraehenbuehl, T; Kranich, D; Lorenz, E; Lustermann, W; Backes, M; Neise, D; Bretz, T; Mannheim, K

    2009-01-01

    Geiger-mode avalanche photodiodes (G-APD) are promising new sensors for light detection in atmospheric Cherenkov telescopes. In this paper, the design and commissioning of a 36-pixel G-APD prototype camera is presented. The data acquisition is based on the Domino Ring Sampling (DRS2) chip. A sub-nanosecond time resolution has been achieved. Cosmic-ray induced air showers have been recorded using an imaging mirror setup, in a self-triggered mode. This is the first time that such measurements have been carried out with a complete G-APD camera.

  3. Multifrequency spectrum analysis using fully digital G Mode-Kelvin probe force microscopy

    International Nuclear Information System (INIS)

    Collins, Liam; Belianinov, Alex; Somnath, Suhas; Balke, Nina; Kalinin, Sergei V; Jesse, Stephen; Rodriguez, Brian J

    2016-01-01

    Since its inception over two decades ago, Kelvin probe force microscopy (KPFM) has become the standard technique for characterizing electrostatic, electrochemical and electronic properties at the nanoscale. In this work, we present a purely digital, software-based approach to KPFM utilizing big data acquisition and analysis methods. General mode (G-Mode) KPFM works by capturing the entire photodetector data stream, typically at the sampling rate limit, followed by subsequent de-noising, analysis and compression of the cantilever response. We demonstrate that the G-Mode approach allows simultaneous multi-harmonic detection, combined with on-the-fly transfer function correction—required for quantitative CPD mapping. The KPFM approach outlined in this work significantly simplifies the technique by avoiding cumbersome instrumentation optimization steps (i.e. lock in parameters, feedback gains etc), while also retaining the flexibility to be implemented on any atomic force microscopy platform. We demonstrate the added advantages of G-Mode KPFM by allowing simultaneous mapping of CPD and capacitance gradient (C′) channels as well as increased flexibility in data exploration across frequency, time, space, and noise domains. G-Mode KPFM is particularly suitable for characterizing voltage sensitive materials or for operation in conductive electrolytes, and will be useful for probing electrodynamics in photovoltaics, liquids and ionic conductors. (paper)

  4. Motion-robust diffusion tensor acquisition at routine 3T magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yasmin, Hasina; Abe, Osamu; Masutani, Yoshitaka; Hayashi, Naoto; Ohtomo, Kuni; Kabasawa, Hiroyuki; Aoki, Shigeki

    2010-01-01

    We compared different acquisition and reconstruction methods in phantom and human studies in the clinical setting to validate our hypothesis that optimizing the k-space acquisition and reconstruction method could decrease motion artifacts. Diffusion tensor images of a water phantom were obtained with three table displacement magnitudes: 1 mm, 2 mm, and 3 mm. Images were reconstructed using homodyne and zero-fill reconstruction. Overscanning in 8- and 16-k y lines was tested. We performed visual assessment of the artifacts using reconstructed coronal images and analyzed them with Wilcoxon signed-ranks test both for phantom and human studies. Also, fractional anisotropy (FA) changes between acquisition methods were compared. Artifacts due to smaller displacement (1 and 2 mm) were significantly reduced in 16-k y overscan with zero filling. The Wilcoxon signed-ranks test showed significant differences (P<0.031 for reconstruction methods and P<0.016 for overscanning methods). FA changes were statistically significant (P<0.037; Student's t-test). The Wilcoxon signed-ranks test showed significant reductions (P<0.005) in the human study. Motion-induced artifacts can be reduced by optimizing acquisition and reconstruction methods. The techniques described in this study offer an effective method for robust estimation of diffusion tensor in the presence of motion-related artifactual data points. (author)

  5. Plant monitoring and signal validation at HFIR

    International Nuclear Information System (INIS)

    Mullens, J.A.

    1991-01-01

    This paper describes a monitoring system for the Oak Ridge National Laboratory's (ORNL'S) High Flux Isotope Reactor (HFIR). HFIR is an 85 MW pressurized water reactor designed to produce isotopes and intense neutron beams. The monitoring system is described with respect to plant signals and computer system; monitoring overview; data acquisition, logging and network distribution; signal validation; status displays; reactor condition monitoring; reactor operator aids. Future work will include the addition of more plant signals, more signal validation and diagnostic capabilities, improved status display, integration of the system with the RELAP plant simulation and graphical interface, improved operator aids, and an alarm filtering system. 8 refs., 7 figs. (MB)

  6. State of art data acquisition system for large volume plasma device

    International Nuclear Information System (INIS)

    Sugandhi, Ritesh; Srivastava, Pankaj; Sanyasi, Amulya Kumar; Srivastav, Prabhakar; Awasthi, Lalit Mohan; Mattoo, Shiban Krishna; Parmar, Vijay; Makadia, Keyur; Patel, Ishan; Shah, Sandeep

    2015-01-01

    The Large volume plasma device (LVPD) is a cylindrical device (ϕ = 2m, L = 3m) dedicated for carrying out investigations on plasma physics problems ranging from excitation of whistler structures to plasma turbulence especially, exploring the linear and nonlinear aspects of electron temperature gradient(ETG) driven turbulence, plasma transport over the entire cross section of LVPD. The machine operates in a pulsed mode with repetition cycle of 1 Hz and acquisition pulse length of duration of 15 ms, presently, LVPD has VXI data acquisition system but this is now in phasing out mode because of non-functioning of its various amplifier stages, expandability and unavailability of service support. The VXI system has limited capabilities to meet new experimental requirements in terms of numbers of channel (16), bit resolutions (8 bit), record length (30K points) and calibration support. Recently, integration of new acquisition system for simultaneous sampling of 40 channels of data, collected over multiple time scales with high speed is successfully demonstrated, by configuring latest available hardware and in-house developed software solutions. The operational feasibility provided by LabVIEW platform is not only for operating DAQ system but also for providing controls to various subsystems associated with the device. The new system is based on PXI express instrumentation bus and supersedes the existing VXI based data acquisition system in terms of instrumentation capabilities. This system has capability to measure 32 signals at 60 MHz sampling frequency and 8 signals with 1.25 GHz with 10 bit and 12 bit resolution capability for amplitude measurements. The PXI based system successfully addresses and demonstrate the issues concerning high channel count, high speed data streaming and multiple I/O modules synchronization. The system consists of chassis (NI 1085), 4 high sampling digitizers (NI 5105), 2 very high sampling digitizers (NI 5162), data streaming RAID drive (NI

  7. Beyond the intelligent-shell concept. The clean-mode-control for tearing perturbations

    International Nuclear Information System (INIS)

    Zanca, Paolo

    2010-01-01

    The Intelligent Shell scheme, where a grid of active coils counteracts in a feedback scheme the measurements provided by an identical grid of sensors, has shown some limitations in the control of the dynamo tearing modes in RFX-mod. The origin of the problem is the aliasing on the measurements coming from the high periodicity sideband harmonics produced by the discrete nature of the active coils. A more efficient feedback on tearing modes is obtained by removing the sidebands from the measurements, thereby counteracting the true tearing Fourier modes. In this scheme, named Clean-Mode-Control, the sidebands are computed in real time from the coils currents using the cylindrical geometry approximation. The Clean-Mode-Control significantly alleviates the wall-locking of tearing modes in RFX-mod, giving the possibility of operating at a plasma current (1.5 MA) never reached before in a RFP machine. These features are well explained by a MHD model describing the tearing mode dynamic under the viscous torque due to the fluid motion and the electromagnetic torques produced by the feedback, the conductive structures surrounding the plasma and the non-linear interaction between the different modes. Here some new results obtained with this model are discussed. In particular we will show that the edge radial field control improves by reducing the ratio between the delay introduced by the digital acquisition of the measurements and the time constant of the shell that contains the plasma. In this formulation the active coils are assumed to be located outside the shell. (author)

  8. Use of Low-Cost Acquisition Systems with an Embedded Linux Device for Volcanic Monitoring.

    Science.gov (United States)

    Moure, David; Torres, Pedro; Casas, Benito; Toma, Daniel; Blanco, María José; Del Río, Joaquín; Manuel, Antoni

    2015-08-19

    This paper describes the development of a low-cost multiparameter acquisition system for volcanic monitoring that is applicable to gravimetry and geodesy, as well as to the visual monitoring of volcanic activity. The acquisition system was developed using a System on a Chip (SoC) Broadcom BCM2835 Linux operating system (based on DebianTM) that allows for the construction of a complete monitoring system offering multiple possibilities for storage, data-processing, configuration, and the real-time monitoring of volcanic activity. This multiparametric acquisition system was developed with a software environment, as well as with different hardware modules designed for each parameter to be monitored. The device presented here has been used and validated under different scenarios for monitoring ocean tides, ground deformation, and gravity, as well as for monitoring with images the island of Tenerife and ground deformation on the island of El Hierro.

  9. Quasinormal Modes and Strong Cosmic Censorship

    Science.gov (United States)

    Cardoso, Vitor; Costa, João L.; Destounis, Kyriakos; Hintz, Peter; Jansen, Aron

    2018-01-01

    The fate of Cauchy horizons, such as those found inside charged black holes, is intrinsically connected to the decay of small perturbations exterior to the event horizon. As such, the validity of the strong cosmic censorship (SCC) conjecture is tied to how effectively the exterior damps fluctuations. Here, we study massless scalar fields in the exterior of Reissner-Nordström-de Sitter black holes. Their decay rates are governed by quasinormal modes of the black hole. We identify three families of modes in these spacetimes: one directly linked to the photon sphere, well described by standard WKB-type tools; another family whose existence and time scale is closely related to the de Sitter horizon; finally, a third family which dominates for near-extremally charged black holes and which is also present in asymptotically flat spacetimes. The last two families of modes seem to have gone unnoticed in the literature. We give a detailed description of linear scalar perturbations of such black holes, and conjecture that SCC is violated in the near extremal regime.

  10. Quantitative detection of caffeine in human skin by confocal Raman spectroscopy--A systematic in vitro validation study.

    Science.gov (United States)

    Franzen, Lutz; Anderski, Juliane; Windbergs, Maike

    2015-09-01

    For rational development and evaluation of dermal drug delivery, the knowledge of rate and extent of substance penetration into the human skin is essential. However, current analytical procedures are destructive, labor intense and lack a defined spatial resolution. In this context, confocal Raman microscopy bares the potential to overcome current limitations in drug depth profiling. Confocal Raman microscopy already proved its suitability for the acquisition of qualitative penetration profiles, but a comprehensive investigation regarding its suitability for quantitative measurements inside the human skin is still missing. In this work, we present a systematic validation study to deploy confocal Raman microscopy for quantitative drug depth profiling in human skin. After we validated our Raman microscopic setup, we successfully established an experimental procedure that allows correlating the Raman signal of a model drug with its controlled concentration in human skin. To overcome current drawbacks in drug depth profiling, we evaluated different modes of peak correlation for quantitative Raman measurements and offer a suitable operating procedure for quantitative drug depth profiling in human skin. In conclusion, we successfully demonstrate the potential of confocal Raman microscopy for quantitative drug depth profiling in human skin as valuable alternative to destructive state-of-the-art techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Three-dimensional analysis of relationship between relative orientation and motion modes

    Directory of Open Access Journals (Sweden)

    Fan Shijie

    2014-12-01

    Full Text Available Target motion modes have a close relationship with the relative orientation of missile-to-target in three-dimensional highly maneuvering target interception. From the perspective of relationship between the sensor coordinate system and the target body coordinate system, a basic model of sensor is stated and the definition of relative angular velocity between the two coordinate systems is introduced firstly. Then, the three-dimensional analytic expressions of relative angular velocity for different motion modes are derived and simplified by analyzing the influences of target centroid motion, rotation around centroid and relative motion. Finally, the relationships of the relative angular velocity directions and values with motion modes are discussed. Simulation results validate the rationality of the theoretical analysis. It is demonstrated that there are significant differences of the relative orientation in different motion modes which include luxuriant information about motion modes. The conclusions are significant for the research of motion mode identification, maneuver detection, maneuvering target tracking and interception using target signatures.

  12. Finite element modeling of trolling-mode AFM.

    Science.gov (United States)

    Sajjadi, Mohammadreza; Pishkenari, Hossein Nejat; Vossoughi, Gholamreza

    2018-06-01

    Trolling mode atomic force microscopy (TR-AFM) has overcome many imaging problems in liquid environments by considerably reducing the liquid-resonator interaction forces. The finite element model of the TR-AFM resonator considering the effects of fluid and nanoneedle flexibility is presented in this research, for the first time. The model is verified by ABAQUS software. The effect of installation angle of the microbeam relative to the horizon and the effect of fluid on the system behavior are investigated. Using the finite element model, frequency response curve of the system is obtained and validated around the frequency of the operating mode by the available experimental results, in air and liquid. The changes in the natural frequencies in the presence of liquid are studied. The effects of tip-sample interaction on the excitation of higher order modes of the system are also investigated in air and liquid environments. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Technical advances in proteomics: new developments in data-independent acquisition [version 1; referees: 3 approved

    Directory of Open Access Journals (Sweden)

    Alex Hu

    2016-03-01

    Full Text Available The ultimate aim of proteomics is to fully identify and quantify the entire complement of proteins and post-translational modifications in biological samples of interest. For the last 15 years, liquid chromatography-tandem mass spectrometry (LC-MS/MS in data-dependent acquisition (DDA mode has been the standard for proteomics when sampling breadth and discovery were the main objectives; multiple reaction monitoring (MRM LC-MS/MS has been the standard for targeted proteomics when precise quantification, reproducibility, and validation were the main objectives. Recently, improvements in mass spectrometer design and bioinformatics algorithms have resulted in the rediscovery and development of another sampling method: data-independent acquisition (DIA. DIA comprehensively and repeatedly samples every peptide in a protein digest, producing a complex set of mass spectra that is difficult to interpret without external spectral libraries. Currently, DIA approaches the identification breadth of DDA while achieving the reproducible quantification characteristic of MRM or its newest version, parallel reaction monitoring (PRM. In comparative de novo identification and quantification studies in human cell lysates, DIA identified up to 89% of the proteins detected in a comparable DDA experiment while providing reproducible quantification of over 85% of them. DIA analysis aided by spectral libraries derived from prior DIA experiments or auxiliary DDA data produces identification and quantification as reproducible and precise as that achieved by MRM/PRM, except on low‑abundance peptides that are obscured by stronger signals. DIA is still a work in progress toward the goal of sensitive, reproducible, and precise quantification without external spectral libraries. New software tools applied to DIA analysis have to deal with deconvolution of complex spectra as well as proper filtering of false positives and false negatives. However, the future outlook is

  14. Improvement of Sidestream Dark Field Imaging with an Image Acquisition Stabilizer

    OpenAIRE

    Balestra, Gianmarco M; Bezemer, Rick; Boerma, E Christiaan; Yong, Ze-Yie; Sjauw, Krishan D; Engstrom, Annemarie E; Koopmans, Matty; Ince, Can

    2010-01-01

    Abstract Background In the present study we developed, evaluated in volunteers, and clinically validated an image acquisition stabilizer (IAS) for Sidestream Dark Field (SDF) imaging. Methods The IAS is a stainless steel sterilizable ring which fits around the SDF probe tip. The IAS creates adhesion to the imaged tissue by application of negative pressure. The effects of the IAS on the sublingual microcirculatory flow velocities, the force required to induce pressure artifacts (PA), the time ...

  15. Mode Shape Analysis of Multiple Cracked Functionally Graded Timoshenko Beams

    Directory of Open Access Journals (Sweden)

    Tran Van Lien

    Full Text Available Abstract The present paper addresses free vibration of multiple cracked Timoshenko beams made of Functionally Graded Material (FGM. Cracks are modeled by rotational spring of stiffness calculated from the crack depth and material properties vary according to the power law throughout the beam thickness. Governing equations for free vibration of the beam are formulated with taking into account actual position of the neutral plane. The obtained frequency equation and mode shapes are used for analysis of the beam mode shapes in dependence on the material and crack parameters. Numerical results validate usefulness of the proposed herein theory and show that mode shapes are good indication for detecting multiple cracks in Timoshenko FGM beams.

  16. 75 FR 54524 - Defense Federal Acquisition Regulation Supplement; Acquisition Strategies To Ensure Competition...

    Science.gov (United States)

    2010-09-08

    ...., because the changes are to internal Government organization and operating procedures only. The rule... 48 CFR Part 207 Government procurement. Ynette R. Shelkin, Editor, Defense Acquisition Regulations... Life Cycle of Major Defense Acquisition Programs (DFARS Case 2009-D014) AGENCY: Defense Acquisition...

  17. Evaluation of early-phase [18F]-florbetaben PET acquisition in clinical routine cases

    Directory of Open Access Journals (Sweden)

    Sonja Daerr

    2017-01-01

    Conclusions: Early-phase FBB acquisitions correlate on a relative quantitative and visual level with FDG PET scans, irrespective of the amyloid plaque density assessed in late FBB imaging. Thus, early-phase FBB uptake depicts a metabolism-like image, suggesting it as a valid surrogate marker for synaptic dysfunction, which could ultimately circumvent the need for additional FDG PET investigation in diagnosis of dementia.

  18. Current Mode Neutron Noise Measurements in the Zero Power Reactor CROCUS

    Science.gov (United States)

    Pakari, O.; Lamirand, V.; Perret, G.; Braun, L.; Frajtag, P.; Pautz, A.

    2018-01-01

    The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff / λ, the effective delayed neutron fraction βeff, and the mean generation time λ for code validation efforts. At higher detection rates, i.e. above 2×104 cps in the used configuration at 0.1 W, the previously employed pulse charge amplification electronics with BF3 detectors yielded erroneous results due to dead time effects. Future experimental needs call for higher sensitivity in detectors, higher detection rates or higher reactor powers, and thus a generally more versatile measurement system. We, therefore, explored detectors operated with current mode acquisition electronics to accommodate the need. We approached the matter in two ways: 1) By using the two compensated 10B-coated ionization chambers available in CROCUS as operational monitors. The compensated current signal of these chambers was extracted from coremonitoring output channels. 2) By developing a new current mode amplification station to be used with other available detectors in core. Characteristics and first noise measurements of the new current system are presented. We implemented post-processing of the current signals from 1)and 2) with the APSD/CPSD method to determine α. At two critical states (0.5 and 1.5 W), using the 10B ionization chambers and their CPSD estimate, the prompt decay constant was measured after 1.5 hours to be α=(156.9 ± 4.3) s-1 (1σ). This result is within 1σ of statistical uncertainties of previous experiments and MCNPv5-1.6 predictions using the ENDF/B-7.1 library. The newsystem connected to a CFUL01 fission chamber using the APSDestimate at 100 mW after 33 min yielded α = (160.8 ± 6.3) s-1, also within 1σ agreement. The improvements to previous neutron noise

  19. Consistency of FMEA used in the validation of analytical procedures.

    Science.gov (United States)

    Oldenhof, M T; van Leeuwen, J F; Nauta, M J; de Kaste, D; Odekerken-Rombouts, Y M C F; Vredenbregt, M J; Weda, M; Barends, D M

    2011-02-20

    In order to explore the consistency of the outcome of a Failure Mode and Effects Analysis (FMEA) in the validation of analytical procedures, an FMEA was carried out by two different teams. The two teams applied two separate FMEAs to a High Performance Liquid Chromatography-Diode Array Detection-Mass Spectrometry (HPLC-DAD-MS) analytical procedure used in the quality control of medicines. Each team was free to define their own ranking scales for the probability of severity (S), occurrence (O), and detection (D) of failure modes. We calculated Risk Priority Numbers (RPNs) and we identified the failure modes above the 90th percentile of RPN values as failure modes needing urgent corrective action; failure modes falling between the 75th and 90th percentile of RPN values were identified as failure modes needing necessary corrective action, respectively. Team 1 and Team 2 identified five and six failure modes needing urgent corrective action respectively, with two being commonly identified. Of the failure modes needing necessary corrective actions, about a third were commonly identified by both teams. These results show inconsistency in the outcome of the FMEA. To improve consistency, we recommend that FMEA is always carried out under the supervision of an experienced FMEA-facilitator and that the FMEA team has at least two members with competence in the analytical method to be validated. However, the FMEAs of both teams contained valuable information that was not identified by the other team, indicating that this inconsistency is not always a drawback. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Reliability and validity of the Safe Routes to school parent and student surveys

    Directory of Open Access Journals (Sweden)

    Evenson Kelly R

    2011-06-01

    Full Text Available Abstract Background The purpose of this study is to assess the reliability and validity of the U.S. National Center for Safe Routes to School's in-class student travel tallies and written parent surveys. Over 65,000 tallies and 374,000 parent surveys have been completed, but no published studies have examined their measurement properties. Methods Students and parents from two Charlotte, NC (USA elementary schools participated. Tallies were conducted on two consecutive days using a hand-raising protocol; on day two students were also asked to recall the previous days' travel. The recall from day two was compared with day one to assess 24-hour test-retest reliability. Convergent validity was assessed by comparing parent-reports of students' travel mode with student-reports of travel mode. Two-week test-retest reliability of the parent survey was assessed by comparing within-parent responses. Reliability and validity were assessed using kappa statistics. Results A total of 542 students participated in the in-class student travel tally reliability assessment and 262 parent-student dyads participated in the validity assessment. Reliability was high for travel to and from school (kappa > 0.8; convergent validity was lower but still high (kappa > 0.75. There were no differences by student grade level. Two-week test-retest reliability of the parent survey (n = 112 ranged from moderate to very high for objective questions on travel mode and travel times (kappa range: 0.62 - 0.97 but was substantially lower for subjective assessments of barriers to walking to school (kappa range: 0.31 - 0.76. Conclusions The student in-class student travel tally exhibited high reliability and validity at all elementary grades. The parent survey had high reliability on questions related to student travel mode, but lower reliability for attitudinal questions identifying barriers to walking to school. Parent survey design should be improved so that responses clearly indicate

  1. Reliability and validity of the Safe Routes to school parent and student surveys.

    Science.gov (United States)

    McDonald, Noreen C; Dwelley, Amanda E; Combs, Tabitha S; Evenson, Kelly R; Winters, Richard H

    2011-06-08

    The purpose of this study is to assess the reliability and validity of the U.S. National Center for Safe Routes to School's in-class student travel tallies and written parent surveys. Over 65,000 tallies and 374,000 parent surveys have been completed, but no published studies have examined their measurement properties. Students and parents from two Charlotte, NC (USA) elementary schools participated. Tallies were conducted on two consecutive days using a hand-raising protocol; on day two students were also asked to recall the previous days' travel. The recall from day two was compared with day one to assess 24-hour test-retest reliability. Convergent validity was assessed by comparing parent-reports of students' travel mode with student-reports of travel mode. Two-week test-retest reliability of the parent survey was assessed by comparing within-parent responses. Reliability and validity were assessed using kappa statistics. A total of 542 students participated in the in-class student travel tally reliability assessment and 262 parent-student dyads participated in the validity assessment. Reliability was high for travel to and from school (kappa > 0.8); convergent validity was lower but still high (kappa > 0.75). There were no differences by student grade level. Two-week test-retest reliability of the parent survey (n=112) ranged from moderate to very high for objective questions on travel mode and travel times (kappa range: 0.62-0.97) but was substantially lower for subjective assessments of barriers to walking to school (kappa range: 0.31-0.76). The student in-class student travel tally exhibited high reliability and validity at all elementary grades. The parent survey had high reliability on questions related to student travel mode, but lower reliability for attitudinal questions identifying barriers to walking to school. Parent survey design should be improved so that responses clearly indicate issues that influence parental decision making in regards to their

  2. Research on Synthetic Aperture Radar Processing for the Spaceborne Sliding Spotlight Mode.

    Science.gov (United States)

    Shen, Shijian; Nie, Xin; Zhang, Xinggan

    2018-02-03

    Gaofen-3 (GF-3) is China' first C-band multi-polarization synthetic aperture radar (SAR) satellite, which also provides the sliding spotlight mode for the first time. Sliding-spotlight mode is a novel mode to realize imaging with not only high resolution, but also wide swath. Several key technologies for sliding spotlight mode in spaceborne SAR with high resolution are investigated in this paper, mainly including the imaging parameters, the methods of velocity estimation and ambiguity elimination, and the imaging algorithms. Based on the chosen Convolution BackProjection (CBP) and PFA (Polar Format Algorithm) imaging algorithms, a fast implementation method of CBP and a modified PFA method suitable for sliding spotlight mode are proposed, and the processing flows are derived in detail. Finally, the algorithms are validated by simulations and measured data.

  3. Research on Synthetic Aperture Radar Processing for the Spaceborne Sliding Spotlight Mode

    Directory of Open Access Journals (Sweden)

    Shijian Shen

    2018-02-01

    Full Text Available Gaofen-3 (GF-3 is China’ first C-band multi-polarization synthetic aperture radar (SAR satellite, which also provides the sliding spotlight mode for the first time. Sliding-spotlight mode is a novel mode to realize imaging with not only high resolution, but also wide swath. Several key technologies for sliding spotlight mode in spaceborne SAR with high resolution are investigated in this paper, mainly including the imaging parameters, the methods of velocity estimation and ambiguity elimination, and the imaging algorithms. Based on the chosen Convolution BackProjection (CBP and PFA (Polar Format Algorithm imaging algorithms, a fast implementation method of CBP and a modified PFA method suitable for sliding spotlight mode are proposed, and the processing flows are derived in detail. Finally, the algorithms are validated by simulations and measured data.

  4. Method of administration of PROMIS scales did not significantly impact score level, reliability, or validity

    DEFF Research Database (Denmark)

    Bjorner, Jakob B; Rose, Matthias; Gandek, Barbara

    2014-01-01

    OBJECTIVES: To test the impact of the method of administration (MOA) on score level, reliability, and validity of scales developed in the Patient Reported Outcomes Measurement Information System (PROMIS). STUDY DESIGN AND SETTING: Two nonoverlapping parallel forms each containing eight items from......, no significant mode differences were found and all confidence intervals were within the prespecified minimal important difference of 0.2 standard deviation. Parallel-forms reliabilities were very high (ICC = 0.85-0.93). Only one across-mode ICC was significantly lower than the same-mode ICC. Tests of validity...... questionnaire (PQ), personal digital assistant (PDA), or personal computer (PC) and a second form by PC, in the same administration. Method equivalence was evaluated through analyses of difference scores, intraclass correlations (ICCs), and convergent/discriminant validity. RESULTS: In difference score analyses...

  5. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  6. Minus 3: a general purpose data acquisition system at LBL's 88''-cyclotron and superhilac

    International Nuclear Information System (INIS)

    Maples, C.; Sivak, J.

    1979-05-01

    MINUS 3 is a general, multi-tasked data acquisition package operating on the ModComp IV/25 computers at both the 88''-Cyclotron and SuperHILAC. It currently can acquire data via three different channels: interrupt; serial DMA link; and remote slave units for histogram type data. Two additional acquisition paths, CAMAC (with programmable differential branch drivers) and MODACS (for multiple CPU linkages and control) are scheduled to be added in the near future. The package operates in a prioritized, time-available mode which permits it to dynamically adapt to microscopic data rate structures due to beam characteristics at different accelerators. Special hardware has been added to the graphics system to provide enhanced high-speed interactive capability. The program framework is also designed as a parasitic environment in which users may, in parallel, attach their own specialized and independent code

  7. Charge and pairing dynamics in the attractive Hubbard model: Mode coupling and the validity of linear-response theory

    Science.gov (United States)

    Bünemann, Jörg; Seibold, Götz

    2017-12-01

    Pump-probe experiments have turned out as a powerful tool in order to study the dynamics of competing orders in a large variety of materials. The corresponding analysis of the data often relies on standard linear-response theory generalized to nonequilibrium situations. Here we examine the validity of such an approach for the charge and pairing response of systems with charge-density wave and (or) superconducting (SC) order. Our investigations are based on the attractive Hubbard model which we study within the time-dependent Hartree-Fock approximation. In particular, we calculate the quench and pump-probe dynamics for SC and charge order parameters in order to analyze the frequency spectra and the coupling of the probe field to the specific excitations. Our calculations reveal that the "linear-response assumption" is justified for small to moderate nonequilibrium situations (i.e., pump pulses) in the case of a purely charge-ordered ground state. However, the pump-probe dynamics on top of a superconducting ground state is determined by phase and amplitude modes which get coupled far from the equilibrium state indicating the failure of the linear-response assumption.

  8. Using quasi-guided modes for modeling the transfer behavior of bent dielectric slab waveguides

    Directory of Open Access Journals (Sweden)

    M. Stallein

    2010-09-01

    Full Text Available The connection of two straight dielectric multimode slab waveguides by a circular bent waveguide is analyzed by means of quasi-guided modes. These modes correspond to the well known leaky modes, but own real eigenvalues, thus the mathematical description is simpler. Furthermore they are derived as approximate solutions of the exact theory. This work will first give a brief introduction to the basic theory, followed by a discussion of the properties of quasi-guided modes. After a validation by comparison with a numerical simulation using the Finite Integration Technique, results for the bending loss of multimode waveguides are presented.

  9. Multifractality in edge localized modes in Japan Atomic Energy Research Institute Tokamak-60 Upgrade

    International Nuclear Information System (INIS)

    Bak, P.E.; Asakura, N.; Miura, Y.; Nakano, T.; Yoshino, R.

    2001-01-01

    The temporal losses of confinement during edge localized modes in the Japan Atomic Energy Research Institute Tokamak-60 Upgrade (JT-60U) show multifractal scaling and the spectra are generally smooth, but in some cases there are signs of discontinuous derivatives. Dynamics of the Sugama-Horton model, interpreted as edge localized modes, also display multifractal scaling. The spectra display singularities in the derivative, which can be interpreted as a phase transition. It is argued that the multifractal spectra of edge localized modes can be used to discriminate between different experimental discharges and validate edge localized mode models

  10. Acquisitions Everywhere: Modeling an Acquisitions Data Standard to Connect a Distributed Environment

    OpenAIRE

    Hanson, Eric M.; Lightcap, Paul W.; Miguez, Matthew R.

    2016-01-01

    Acquisitions functions remain operationally crucial in providing access to paid information resources, but data formats and workflows utilized within library acquisitions remain primarily within the traditional integrated library system (ILS). As libraries have evolved to use distributed systems to manage information resources, so too must acquisitions functions adapt to an environment that may include the ILS, e‐resource management systems (ERMS), institutional repositories (IR), and other d...

  11. Modification and Validation of an Automotive Data Processing Unit, Compessed Video System, and Communications Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.

    1997-04-01

    The primary purpose of the "modification and validation of an automotive data processing unit (DPU), compressed video system, and communications equipment" cooperative research and development agreement (CRADA) was to modify and validate both hardware and software, developed by Scientific Atlanta, Incorporated (S-A) for defense applications (e.g., rotary-wing airplanes), for the commercial sector surface transportation domain (i.e., automobiles and trucks). S-A also furnished a state-of-the-art compressed video digital storage and retrieval system (CVDSRS), and off-the-shelf data storage and transmission equipment to support the data acquisition system for crash avoidance research (DASCAR) project conducted by Oak Ridge National Laboratory (ORNL). In turn, S-A received access to hardware and technology related to DASCAR. DASCAR was subsequently removed completely and installation was repeated a number of times to gain an accurate idea of complete installation, operation, and removal of DASCAR. Upon satisfactory completion of the DASCAR construction and preliminary shakedown, ORNL provided NHTSA with an operational demonstration of DASCAR at their East Liberty, OH test facility. The demonstration included an on-the-road demonstration of the entire data acquisition system using NHTSA'S test track. In addition, the demonstration also consisted of a briefing, containing the following: ORNL generated a plan for validating the prototype data acquisition system with regard to: removal of DASCAR from an existing vehicle, and installation and calibration in other vehicles; reliability of the sensors and systems; data collection and transmission process (data integrity); impact on the drivability of the vehicle and obtrusiveness of the system to the driver; data analysis procedures; conspicuousness of the vehicle to other drivers; and DASCAR installation and removal training and documentation. In order to identify any operational problems not captured by the systems

  12. 48 CFR 434.004 - Acquisition strategy.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Acquisition strategy. 434.004 Section 434.004 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 434.004 Acquisition strategy. (a) The program...

  13. 48 CFR 873.105 - Acquisition planning.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Acquisition planning. 873.105 Section 873.105 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS DEPARTMENT... planning. (a) Acquisition planning is an indispensable component of the total acquisition process. (b) For...

  14. 48 CFR 34.004 - Acquisition strategy.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Acquisition strategy. 34... CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.004 Acquisition strategy. The program manager, as specified in agency procedures, shall develop an acquisition strategy tailored to the particular...

  15. 48 CFR 3034.004 - Acquisition strategy.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Acquisition strategy. 3034.004 Section 3034.004 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND... Acquisition strategy. See (HSAR) 48 CFR 3009.570 for policy applicable to acquisition strategies that consider...

  16. Laboratory Validation and Demonstrations of Non-Hexavalent Chromium Conversion Coatings for Steel Substrates (Briefing Charts)

    Science.gov (United States)

    2011-02-01

    UNCLASSIFIED: Approved for public release; distribution unlimited. Laboratory Validation and Demonstrations of Non- Hexavalent Chromium Conversion...00-00-2011 4. TITLE AND SUBTITLE Laboratory Validation and Demonstrations of Non- Hexavalent Chromium Conversion Coatings for Steel Substrates 5a...to MRAP II Acquisition Pretreatment /conversion coatings omitted: • Hex- chrome pretreatments prohibited for new ground vehicles • Hydrogen

  17. Age of Acquisition Effects in Chinese EFL learners’ Delexicalized Verb and Collocation Acquisition

    Directory of Open Access Journals (Sweden)

    Miao Haiyan

    2015-05-01

    Full Text Available This paper investigates age of acquisition (AoA effects and the acquisition of delexicalized verbs and collocations in Chinese EFL learners, and explores the underlying reasons from the connectionist model for these learners’ acquisition characteristics. The data were collected through a translation test consisted of delexialized verb information section and English-Chinese and Chinese-English collocation parts, aiming to focus on Chinese EFL learners’ receptive and productive abilities respectively. As Chinese EFL is a nationally classroom-based practice beginning from early primary school, the pedagogical value and different phases of acquisition are thus taken into consideration in designing the translation test. Research results show that the effects of AoA are significant not only in the learners’ acquisition of individual delexicalized verbs but also in delexicalized collocations. Although learners have long begun to learn delexicalized verbs, their production indicates that early learning does not guarantee total acquisition, because their grasp of delexicalized verbs still stay at the senior middle school level. AoA effects significantly affect the recognition but not the production of collocations. Furthermore, a plateau effect occurs in learners’ acquisition of college-level delexicalized collocations, as their recognition and production have no processing advantages over earlier learned collocations.

  18. Reduced rectal toxicity with ultrasound-based image guided radiotherapy using BAT trademark (B-mode acquisition and targeting system) for prostate cancer

    International Nuclear Information System (INIS)

    Bohrer, Markus; Schroeder, Peter; Welzel, Grit; Wertz, Hansjoerg; Lohr, Frank; Wenz, Frederik; Mai, Sabine Kathrin

    2008-01-01

    To evaluate the effect of image guided radiotherapy with stereotactic ultrasound BAT (B-mode acquisition and targeting system) on rectal toxicity in conformal radiotherapy of prostate cancer. Patients and Methods 42 sequential patients with prostate cancer undergoing radiotherapy before and after the introduction of BAT were included. Planning computed tomography (CT) was performed with empty rectum and moderately filled bladder. The planning target volume (PTV) included the prostate and seminal vesicles with a safety margin of 1.5 cm in anterior and lateral direction. In posterior direction the anterior 1/3 of the rectum circumference were included. Total dose was 66 Gy and a boost of 4 Gy excluding the seminal vesicles. 22 patients (BAT group) were treated with daily stereotactic ultrasound positioning, for the other 20 patients (NoBAT group) an EPID (electronic portal imaging device) was performed once a week. Acute and late genito-urinary (GU) and rectal toxicity and PSA values were evaluated after 1.5, 3, 6, 9 and 12 months. The total median follow up of toxicity was 3 years in the BAT group and 4 years in the NoBAT group. Results In the NoBAT group significant more rectal toxicity occurred, while in GU toxicity no difference was seen. Two patients in the NoBAT group showed late rectal toxicity grade 3, no toxicity > grade 2 occurred in the BAT group. There was no significant difference in PSA reduction between the groups. Conclusion Without BAT significant more acute and a trend to more late rectal toxicity was found. With regard to dose escalation this aspect is currently evaluated with a larger number of patients using intensity-modulated radiotherapy (IMRT). (orig.)

  19. Sustaining an Acquisition-based Growth Strategy

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Toppenberg, Gustav; Shanks, Graeme

    Value creating acquisitions are a major challenge for many firms. Our case study of Cisco Systems shows that an advanced Enterprise Architecture (EA) capability can contribute to the acquisition process through a) preparing the acquirer to become ‘acquisition ready’, b) identifying resource...... complementarity, c) directing and governing the integration process, and d) post-acquisition evaluation of the achieved integration and proposing ways forward. Using the EA capability in the acquisition process improves Cisco’s ability to rapidly capture value from its acquisitions and to sustain its acquisition...

  20. 48 CFR 234.004 - Acquisition strategy.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Acquisition strategy. 234..., DEPARTMENT OF DEFENSE SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION 234.004 Acquisition strategy. (1) See 209.570 for policy applicable to acquisition strategies that consider the use of lead system...

  1. Two-mode PLC-based mode multi/demultiplexer for mode and wavelength division multiplexed transmission.

    Science.gov (United States)

    Hanzawa, Nobutomo; Saitoh, Kuimasa; Sakamoto, Taiji; Matsui, Takashi; Tsujikawa, Kyozo; Koshiba, Masanori; Yamamoto, Fumihiko

    2013-11-04

    We proposed a PLC-based mode multi/demultiplexer (MUX/DEMUX) with an asymmetric parallel waveguide for mode division multiplexed (MDM) transmission. The mode MUX/DEMUX including a mode conversion function with an asymmetric parallel waveguide can be realized by matching the effective indices of the LP(01) and LP(11) modes of two waveguides. We report the design of a mode MUX/DEMUX that can support C-band WDM-MDM transmission. The fabricated mode MUX/DEMUX realized a low insertion loss of less than 1.3 dB and high a mode extinction ratio that exceeded 15 dB. We used the fabricated mode MUX/DEMUX to achieve a successful 2 mode x 4 wavelength x 10 Gbps transmission over a 9 km two-mode fiber with a penalty of less than 1 dB.

  2. Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition.

    Science.gov (United States)

    Ye, Huihui; Ma, Dan; Jiang, Yun; Cauley, Stephen F; Du, Yiping; Wald, Lawrence L; Griswold, Mark A; Setsompop, Kawin

    2016-05-01

    We incorporate simultaneous multislice (SMS) acquisition into MR fingerprinting (MRF) to accelerate the MRF acquisition. The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the signal from different simultaneously excited slices are encoded with different phases without disturbing the signal evolution. Furthermore, by varying the Gz blip area and/or polarity as a function of repetition time, the slices' differential phase can also be made to vary as a function of time. For reconstruction of t-Blipped SMS-MRF data, we demonstrate a combined slice-direction SENSE and modified dictionary matching method. In Monte Carlo simulation, the parameter mapping from multiband factor (MB) = 2 t-Blipped SMS-MRF shows good accuracy and precision when compared with results from reference conventional MRF data with concordance correlation coefficients (CCC) of 0.96 for T1 estimates and 0.90 for T2 estimates. For in vivo experiments, T1 and T2 maps from MB=2 t-Blipped SMS-MRF have a high agreement with ones from conventional MRF. The MB=2 t-Blipped SMS-MRF acquisition/reconstruction method has been demonstrated and validated to provide more rapid parameter mapping in the MRF framework. © 2015 Wiley Periodicals, Inc.

  3. Vibrational lifetimes of protein amide modes

    International Nuclear Information System (INIS)

    Peterson, K.A.; Rella, C.A.

    1995-01-01

    Measurement of the lifetimes of vibrational modes in proteins has been achieved with a single frequency infrared pump-probe technique using the Stanford Picosecond Free-electron Laser, These are the first direct measurements of vibrational dynamics in the polyamide structure of proteins. In this study, modes associated with the protein backbone are investigated. Results for the amide I band, which consists mainly of the stretching motion of the carbonyl unit of the amide linkage, show that relaxation from the first vibrational excited level (v=1) to the vibrational ground state (v=0) occurs within 1.5 picoseconds with apparent first order kinetics. Comparison of lifetimes for myoglobin and azurin, which have differing secondary structures, show a small but significant difference. The lifetime for the amide I band of myoglobin is 300 femtoseconds shorter than for azurin. Further measurements are in progress on other backbone vibrational modes and on the temperature dependence of the lifetimes. Comparison of vibrational dynamics for proteins with differing secondary structure and for different vibrational modes within a protein will lead to a greater understanding of energy transfer and dissipation in biological systems. In addition, these results have relevance to tissue ablation studies which have been conducted with pulsed infrared lasers. Vibrational lifetimes are necessary for calculating the rate at which the energy from absorbed infrared photons is converted to equilibrium thermal energy within the irradiated volume. The very fast vibrational lifetimes measured here indicate that mechanisms which involve direct vibrational up-pumping of the amide modes with consecutive laser pulses, leading to bond breakage or weakening, are not valid

  4. 48 CFR 307.104-70 - Acquisition strategy.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Acquisition strategy. 307... AND ACQUISITION PLANNING ACQUISITION PLANNING Acquisition Planning 307.104-70 Acquisition strategy... designated by the HHS CIO, DASFMP, the CAO, or the cognizant HCA) shall prepare an acquisition strategy using...

  5. Vulnerability in Acquisition, Language Impairments in Dutch: Creating a VALID Data Archive

    NARCIS (Netherlands)

    Klatter, J.; van Hout, R.; van den Heuvel, H.; Fikkert, P.; Baker, A.; de Jong, J.; Wijnen, F.; Sanders, E.; Trilsbeek, P.; Calzolari, N.; Choukri, K.; Declerck, T.; Maegaard, H.B.; Mariani, J.; Moreno, A.; Odijk, J.; Piperidis, S.

    2014-01-01

    The VALID Data Archive is an open multimedia data archive (under construction) with data from speakers suffering from language impairments. We report on a pilot project in the CLARIN-NL framework in which five data resources were curated. For all data sets concerned, written informed consent from

  6. Validation of safeguards monitoring systems and their simulations

    International Nuclear Information System (INIS)

    Standley, V.; Boeck, H.; Villa, M.

    2001-01-01

    Research is underway at the Atominstitut in Vienna Austria where the objective is to design and validate quantitatively a safeguards monitoring system (SMS) and its simulation. The work is novel because the simulation is also used as the basis for automated evaluation of SMS data. Preliminary results indicate that video and radiation data can be automatically interpreted using this approach. Application of the technique promises that an investment in a simulation supports directly the safeguards objective, which is to catch diversion of nuclear material. Consequently, it is easier for a safeguards agency to also realize other benefits associated with simulation-based acquisition, in addition to having a quantitative method for validation

  7. THE INFLUENCE OF HOME COUNTRY MACROECONOMIC FACTORS ON INWARD CROSS-BORDER MERGERS AND ACQUISITIONS: THE CASE OF ROMANIA

    Directory of Open Access Journals (Sweden)

    Sehleanu Mariana

    2015-07-01

    Full Text Available Expanding abroad and entering on foreign markets is a natural step in the process of growth and development of firms. Cross-border mergers and acquisitions represent, currently, an important tool in the competitive struggle, which is increasingly intense due to the globalization of economies, and also the driving force behind the growth of Foreign Direct Investments (FDI flows globally. In Romania, the share of cross-border mergers and acquisitions inflows in the total FDI inflows increased progressively, reaching 46,6% in 2006, when the highest value of these transactions was registered (5.308 million dollars, according to UNCTAD. The aim of this empirical research is to study the correlation between the number of inward cross-border mergers acquisitions and a series of other variables, considered factors of influence, over the period 1992-2013. Using simple regression models, the study reveals that economic factors such as Gross domestic product (GDP, stock market capitalization (as a percentage of GDP, interest rate, exchange rate, M2 monetary aggregate and inflation have an important role in explaining cross-border mergers and acquisitions inflows. Between the number of inward cross-border mergers and acquisitions and GDP, M2 monetary aggregate, market capitalization, respectively the exchange rate, there is a direct and linear correlation and between the number of inward mergers and acquisitions and the interest rate, respectively the inflation, there is an inverse linear correlation. The research conducted reveals the important role played by macroeconomic factors with regard to the cross-border mergers and acquisitions inflows, as an entry mode of FDI in Romania.

  8. CORRELATION OF H-MODE BARRIER WIDTH AND NEUTRAL PENETRATION LENGTH

    International Nuclear Information System (INIS)

    GROEBNER, R.J.; MAHDAVI, M.A.; LEONARD, A.W.; OSBORNE, T.H.; WOLF, N.S.; PORTER, G.D.; STANGEBY, P.C.; BROOKS, N.H.; COLCHIN, R.J.; HEIDBRINK, W.W.; LUCE, T.C.; MCKEE, G.R.; OWEN, L.W.; WANG, G.; WHYTE, D.G.

    2002-01-01

    OAK A271 CORRELATION OF H-MODE BARRIER WIDTH AND NEUTRAL PENETRATION LENGTH. Pedestal studies in DIII-D find a good correlation between the width of the H-mode density barrier and the neutral penetration length. These results are obtained by comparing experimental density profiles to the predictions of an analytic model for the profile, obtained from the particle continuity equations for electrons and deuterium atoms. In its range of validity (edge temperature between 40-500 eV), the analytic model quantitatively predicts the observed decrease of the width as the pedestal density increases, the observed strong increase of the gradient of the density as the pedestal density increases and the observation that L-mode and H-mode profiles with the same pedestal density have very similar shapes. The width of the density barrier, measured from the edge of the electron temperature barrier, is the lower limit for the observed width of the temperature barrier. These results support the hypothesis that particle fueling provides the dominant control for the size of the H-mode transport barrier

  9. CORRELATION OF H-MODE BARRIER WIDTH AND NEUTRAL PENTRATION LENGTH

    International Nuclear Information System (INIS)

    GROEBNER, R.J.; MAHDAVI, M.A.; LEONARD, A.W.; OSBORNE, T.H.; WOLF, N.S.; PORTER, G.D.; STANGEBY, P.C.; BROOKS, N.H.; COLCHIN, R.J.; HEIDBRINK, W.W.; LUCE, T.C.; MCKEE, G.R.; OWEN, L.W.; WANG, G.; WHYTE, D.G.

    2002-01-01

    OAK A271 CORRELATION OF H-MODE BARRIER WIDTH AND NEUTRAL PENTRATION LENGTH. Pedestal studies in DIII-D find a good correlation between the width of the region of steep gradient in the H-mode density and the neutral penetration length. These results are obtained by comparing experimental density profiles to the predictions of an analytic model for the profile, obtained from the particle continuity equations for electrons and deuterium atoms. In its range of validity (edge temperature between 40-500 eV), the analytic model quantitatively predicts the observed decrease of the width as the pedestal density increases, the observed strong increase of the gradient of the density as the pedestal density increases and the observation that L-mode and H-mode profiles with the same pedestal density have very similar shapes. The width of the density barrier, measured from the edge of the electron temperature barrier, is the lower limit for the observed width of the temperature barrier. These results support the hypothesis that particle fueling provides a dominant control for the size of the H-mode transport barrier

  10. PARTIAL REINFORCEMENT (ACQUISITION) EFFECTS WITHIN SUBJECTS.

    Science.gov (United States)

    AMSEL, A; MACKINNON, J R; RASHOTTE, M E; SURRIDGE, C T

    1964-03-01

    Acquisition performance of 22 rats in a straight alley runway was examined. The animals were subjected to partial reinforcement when the alley was black (B+/-) and continuous reinforcement when it was white (W+). The results indicated (a) higher terminal performance, for partial as against continuous reinforcement conditions, for starting-time and running-time measures, and (b) lower terminal performance under partial conditions for a goal-entry-time measure. These results confirm within subjects an effect previously demonstrated, in the runway, only in between-groups tests, where one group is run under partial reinforcement and a separate group is run under continuous reinforcement in the presence of the same external stimuli. Differences between the runway situation, employing a discrete-trial procedure and performance measures at three points in the response chain, and the Skinner box situation, used in its free-operant mode with a single performance measure, are discussed in relation to the present findings.

  11. ANGULAR MOMENTUM ACQUISITION IN GALAXY HALOS

    International Nuclear Information System (INIS)

    Stewart, Kyle R.; Brooks, Alyson M.; Bullock, James S.; Maller, Ariyeh H.; Diemand, Jürg; Wadsley, James; Moustakas, Leonidas A.

    2013-01-01

    We use high-resolution cosmological hydrodynamic simulations to study the angular momentum acquisition of gaseous halos around Milky-Way-sized galaxies. We find that cold mode accreted gas enters a galaxy halo with ∼70% more specific angular momentum than dark matter averaged over cosmic time (though with a very large dispersion). In fact, we find that all matter has a higher spin parameter when measured at accretion than when averaged over the entire halo lifetime, and is well characterized by λ ∼ 0.1, at accretion. Combined with the fact that cold flow gas spends a relatively short time (1-2 dynamical times) in the halo before sinking to the center, this naturally explains why cold flow halo gas has a specific angular momentum much higher than that of the halo and often forms ''cold flow disks.'' We demonstrate that the higher angular momentum of cold flow gas is related to the fact that it tends to be accreted along filaments.

  12. The WASA Data Acquisition System (WDAQ)

    CERN Document Server

    Gustafsson, L; Sukhanov, A

    1999-01-01

    The WASA Data Acquisition System (WDAQ) is described. It is a modular, and scalable network based system. The chosen structure facilitate that different old and new front-end electronics standards can work together in an efficient way. Fast hardware triggers are created from discriminated signals from specific parts of the WASA detector by extensive use of programmable logic. The trigger logic is configured to do cluster finding in one or two dimensions. The front- end data is linked together in an event-building switch using the Asynchronous Transfer Mode (ATM) protocol and sent to different PC- stations for further filtering, before put onto tape. The data analysis software is using the ROOT (CERN) system which provides a set of object oriented frameworks with all the functionality needed to handle and analyze large amounts of data in a very efficient way. The slow control software is based on the MIDAS (PSI/TRIUMF) system and comprises a fast online database to keep and monitor all WDAQ parameters. The WAS...

  13. VALIDATION OF THE MECG-DP-NS-01 MONITOR IN OSCILLOMETRY AND AUSCULTATION MODES IN CHILDREN AND ADOLESCENTS, ACCORDING TO ESH-IP2, BHS AND AAMI PROTOCOLS

    Directory of Open Access Journals (Sweden)

    S. I. Fedorova

    2015-01-01

    Full Text Available Background: High blood pressure in childhood and adolescence is associated with a 2 to 3-fold increase of the risk of arterial hypertension. According to the Russian guidelines, only devices that have been tested by international protocols can be used for the main diagnostic method of arterial hypertension in children and adolescents, i.e. ambulatory 24-hour blood pressure monitoring.Aim: To validate the MECG-DP-NS-01 upper arm BP monitor in oscillometry and auscultation modes within the “Soyuz” complex, in children and adolescents aged from 5 to 15 years according to the international protocol of the European Society of Hypertension (ESH from 2010 (ESH-IP2, the protocol of the British Hypertension Society (BHS from 1993 and the standard of the Association for the Advancement of Medical Instrumentation (AAMI.Materials and methods: We recruited 99 children and adolescents (49 male, 50 female aged from 5 to 15 years (33 children, from 5 to 7 years, 33, from 8 to 11 years, 33, from 12 to 15 years. Expert and device blood pressure measurements were performed in each patient according to the protocols.Results: The MECG-DP-NS-01 upper arm blood pressure monitor was validated and its accuracy in blood pressure measurement in children and adolescents according to ESH-IP2, BHS and AAMI protocols confirmed. According to BHS 1993 protocol, its accuracy corresponded to A/A both in the oscillometry and auscultation modes.Conclusion: According to ESH-IP2, BHS and AAMI protocols, MEGC-DP-NS-01 within the “Soyuz” complex could be recommended for 24-hour ambulatory blood pressure monitoring in children and adolescents aged from 5 to 15 years, both in the oscillometry and auscultation modes. According to the Declaration of blood pressure Measuring Device Equivalence signed by the manufacturer for the devices MDP-NS-02s “Voshod” and MEGCDPNS-01, and to the equivalence criteria for blood pressure measuring devices, the results of testing and its

  14. Definition, analysis and experimental investigation of operation modes in hydrogen-renewable-based power plants incorporating hybrid energy storage

    International Nuclear Information System (INIS)

    Valverde, L.; Pino, F.J.; Guerra, J.; Rosa, F.

    2016-01-01

    Highlights: • A conceptual analysis of operation modes in energy storage plants is presented. • Key Performance Indicators to select operation modes are provided. • The approach has been applied to a laboratory hybrid power plant. • The methodology provides guidance for the operation of hybrid power plants. - Abstract: This paper is concerned with Operating Modes in hybrid renewable energy-based power plants with hydrogen as the intermediate energy storage medium. Six operation modes are defined according to plant topology and the possibility of operating electrolyzer and fuel cell at steady-power or partial load. A methodology for the evaluation of plant performance is presented throughout this paper. The approach includes a set of simulations over a fully validated model, which are run in order to compare the proposed operation modes in various weather conditions. Conclusions are drawn from the simulation stage using a set of Key Performance Indicators defined in this paper. This analysis yields the conclusion that certain modes are more appropriate from technical and practical standpoints when they are implemented in a real plant. From the results of the simulation assessment, selected operating modes are applied to an experimental hydrogen-based pilot plant to illustrate and validate the performance of the proposed operation modes. Experimental results confirmed the simulation study, pointing out the advantages and disadvantages of each operation mode in terms of performance and equipment durability.

  15. [First language acquisition research and theories of language acquisition].

    Science.gov (United States)

    Miller, S; Jungheim, M; Ptok, M

    2014-04-01

    In principle, a child can seemingly easily acquire any given language. First language acquisition follows a certain pattern which to some extent is found to be language independent. Since time immemorial, it has been of interest why children are able to acquire language so easily. Different disciplinary and methodological orientations addressing this question can be identified. A selective literature search in PubMed and Scopus was carried out and relevant monographies were considered. Different, partially overlapping phases can be distinguished in language acquisition research: whereas in ancient times, deprivation experiments were carried out to discover the "original human language", the era of diary studies began in the mid-19th century. From the mid-1920s onwards, behaviouristic paradigms dominated this field of research; interests were focussed on the determination of normal, average language acquisition. The subsequent linguistic period was strongly influenced by the nativist view of Chomsky and the constructivist concepts of Piaget. Speech comprehension, the role of speech input and the relevance of genetic disposition became the centre of attention. The interactionist concept led to a revival of the convergence theory according to Stern. Each of these four major theories--behaviourism, cognitivism, interactionism and nativism--have given valuable and unique impulses, but no single theory is universally accepted to provide an explanation of all aspects of language acquisition. Moreover, it can be critically questioned whether clinicians consciously refer to one of these theories in daily routine work and whether therapies are then based on this concept. It remains to be seen whether or not new theories of grammar, such as the so-called construction grammar (CxG), will eventually change the general concept of language acquisition.

  16. Control quality and performance measurement of gamma cameras. S.F.P.M. report nr 28. Updating of S.F.P.H. reports Performance assessment and quality control of scintillation cameras: plane mode (1992), tomographic mode (1996) whole-body mode (1997)

    International Nuclear Information System (INIS)

    Petegnief, Yolande; Barrau, Corinne; Coulot, Jeremy; Guilhem, Marie Therese; Hapdey, Sebastien; Vrigneaud, Jean-Marc; Metayer, Yann; Picone, Magali; Ricard, Marcel; Salvat, Cecile; Bouchet, Francis; Ferrer, Ludovic; Murat, Caroline

    2012-01-01

    This report aims at providing students and professionals with a comprehensive guide related to quality control and to performance measurement on gamma cameras. It completes and updates three previous reports published by the SFPM during the 1990's related to the different acquisition modes for this modality of medical imagery: plane imagery, whole-body scanning, and tomography. The authors present the operation principle of scintillation cameras, the characteristics of a scintillation camera, analytic and algebraic algorithms of tomographic reconstruction, and the various software corrections applied in mono-photonic imagery (corrections of the attenuation effect, of the scattering effect, of the collimator response effect, and of the partial volume effect). In the next part, the present the various characteristics, parameters and issues related to performance measurement for the three addressed modes (plane, whole body, tomographic). The last part presents various aspects of the organisation of quality control and of performance follow-up: regulatory context, reference documents, internal quality control program

  17. Optimization of Acquisition time of 68Ga-PSMA-Ligand PET/MRI in Patients with Local and Metastatic Prostate Cancer.

    Science.gov (United States)

    Lütje, Susanne; Blex, Sebastian; Gomez, Benedikt; Schaarschmidt, Benedikt M; Umutlu, Lale; Forsting, Michael; Jentzen, Walter; Bockisch, Andreas; Poeppel, Thorsten D; Wetter, Axel

    2016-01-01

    The aim of this optimization study was to minimize the acquisition time of 68Ga-HBED-CC-PSMA positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with local and metastatic prostate cancer (PCa) to obtain a sufficient image quality and quantification accuracy without any appreciable loss. Twenty patients with PCa were administered intravenously with the 68Ga-HBED-CC-PSMA ligand (mean activity 99 MBq/patient, range 76-148 MBq) and subsequently underwent PET/MRI at, on average, 168 min (range 77-320 min) after injection. PET and MR imaging data were acquired simultaneously. PET acquisition was performed in list mode and PET images were reconstructed at different time intervals (1, 2, 4, 6, 8, and 10 min). Data were analyzed regarding radiotracer uptake in tumors and muscle tissue and PET image quality. Tumor uptake was quantified in terms of the maximum and mean standardized uptake value (SUVmax, SUVmean) within a spherical volume of interest (VOI). Reference VOIs were drawn in the gluteus maximus muscle on the right side. PET image quality was evaluated by experienced nuclear physicians/radiologists using a five-point ordinal scale from 5-1 (excellent-insufficient). Lesion detectability linearly increased with increasing acquisition times, reaching its maximum at PET acquisition times of 4 min. At this image acquisition time, tumor lesions in 19/20 (95%) patients were detected. PET image quality showed a positive correlation with increasing acquisition time, reaching a plateau at 4-6 min image acquisition. Both SUVmax and SUVmean correlated inversely with acquisition time and reached a plateau at acquisition times after 4 min. In the applied image acquisition settings, the optimal acquisition time of 68Ga-PSMA-ligand PET/MRI in patients with local and metastatic PCa was identified to be 4 min per bed position. At this acquisition time, PET image quality and lesion detectability reach a maximum while SUVmax and SUVmean do not change

  18. Optimization of Acquisition time of 68Ga-PSMA-Ligand PET/MRI in Patients with Local and Metastatic Prostate Cancer.

    Directory of Open Access Journals (Sweden)

    Susanne Lütje

    Full Text Available The aim of this optimization study was to minimize the acquisition time of 68Ga-HBED-CC-PSMA positron emission tomography/magnetic resonance imaging (PET/MRI in patients with local and metastatic prostate cancer (PCa to obtain a sufficient image quality and quantification accuracy without any appreciable loss.Twenty patients with PCa were administered intravenously with the 68Ga-HBED-CC-PSMA ligand (mean activity 99 MBq/patient, range 76-148 MBq and subsequently underwent PET/MRI at, on average, 168 min (range 77-320 min after injection. PET and MR imaging data were acquired simultaneously. PET acquisition was performed in list mode and PET images were reconstructed at different time intervals (1, 2, 4, 6, 8, and 10 min. Data were analyzed regarding radiotracer uptake in tumors and muscle tissue and PET image quality. Tumor uptake was quantified in terms of the maximum and mean standardized uptake value (SUVmax, SUVmean within a spherical volume of interest (VOI. Reference VOIs were drawn in the gluteus maximus muscle on the right side. PET image quality was evaluated by experienced nuclear physicians/radiologists using a five-point ordinal scale from 5-1 (excellent-insufficient.Lesion detectability linearly increased with increasing acquisition times, reaching its maximum at PET acquisition times of 4 min. At this image acquisition time, tumor lesions in 19/20 (95% patients were detected. PET image quality showed a positive correlation with increasing acquisition time, reaching a plateau at 4-6 min image acquisition. Both SUVmax and SUVmean correlated inversely with acquisition time and reached a plateau at acquisition times after 4 min.In the applied image acquisition settings, the optimal acquisition time of 68Ga-PSMA-ligand PET/MRI in patients with local and metastatic PCa was identified to be 4 min per bed position. At this acquisition time, PET image quality and lesion detectability reach a maximum while SUVmax and SUVmean do not change

  19. Design of the M&S acquisition support effort of the SANDF GBADS acquisition programme

    CSIR Research Space (South Africa)

    Nel, JJ

    2007-06-01

    Full Text Available (AmADS) GBADS Phase 2 (MobADS) GBADS Phase 3 (LmADS) GBADS Phase 4 (C2 Optimisation) GBADS Phase 5 (MecADS) Figure 1: GBADS Phased Acquisition. The acquisition programme comprises five phases each addressing the acquisition of a specific... element of the GBADS. Phase 1 addresses an Air-mobile Air Defence System (AmADS) utilising man-portable missiles that can also be employed as a component of a Mobile Air Defence System (MobADS). Phase 2 involves the acquisition of the remainder...

  20. Self-Assessment of Japanese as a Second Language: The Role of Experiences in the Naturalistic Acquisition

    Science.gov (United States)

    Suzuki, Yuichi

    2015-01-01

    Self-assessment has been used to assess second language proficiency; however, as sources of measurement errors vary, they may threaten the validity and reliability of the tools. The present paper investigated the role of experiences in using Japanese as a second language in the naturalistic acquisition context on the accuracy of the…

  1. PLC-based mode multi/demultiplexers for mode division multiplexing

    Science.gov (United States)

    Saitoh, Kunimasa; Hanzawa, Nobutomo; Sakamoto, Taiji; Fujisawa, Takeshi; Yamashita, Yoko; Matsui, Takashi; Tsujikawa, Kyozo; Nakajima, Kazuhide

    2017-02-01

    Recently developed PLC-based mode multi/demultiplexers (MUX/DEMUXs) for mode division multiplexing (MDM) transmission are reviewed. We firstly show the operation principle and basic characteristics of PLC-based MUX/DEMUXs with an asymmetric directional coupler (ADC). We then demonstrate the 3-mode (2LP-mode) multiplexing of the LP01, LP11a, and LP11b modes by using fabricated PLC-based mode MUX/DEMUX on one chip. In order to excite LP11b mode in the same plane, a PLC-based LP11 mode rotator is introduced. Finally, we show the PLC-based 6-mode (4LP-mode) MUX/DEMUX with a uniform height by using ADCs, LP11 mode rotators, and tapered waveguides. It is shown that the LP21a mode can be excited from the LP11b mode by using ADC, and the two nearly degenerated LP21b and LP02 modes can be (de)multiplexed separately by using tapered mode converter from E13 (E31) mode to LP21b (LP02) mode.

  2. Automated mode shape estimation in agent-based wireless sensor networks

    Science.gov (United States)

    Zimmerman, Andrew T.; Lynch, Jerome P.

    2010-04-01

    Recent advances in wireless sensing technology have made it possible to deploy dense networks of sensing transducers within large structural systems. Because these networks leverage the embedded computing power and agent-based abilities integral to many wireless sensing devices, it is possible to analyze sensor data autonomously and in-network. In this study, market-based techniques are used to autonomously estimate mode shapes within a network of agent-based wireless sensors. Specifically, recent work in both decentralized Frequency Domain Decomposition and market-based resource allocation is leveraged to create a mode shape estimation algorithm derived from free-market principles. This algorithm allows an agent-based wireless sensor network to autonomously shift emphasis between improving mode shape accuracy and limiting the consumption of certain scarce network resources: processing time, storage capacity, and power consumption. The developed algorithm is validated by successfully estimating mode shapes using a network of wireless sensor prototypes deployed on the mezzanine balcony of Hill Auditorium, located on the University of Michigan campus.

  3. Correlation of H-mode barrier width and neutral penetration length

    International Nuclear Information System (INIS)

    Groebner, R.J.; Mahdavi, M.A.; Leonard, A.W.

    2003-01-01

    Pedestal studies in DIII-D find a good correlation between the width of the H-mode density barrier and the neutral penetration length. These results are obtained by comparing experimental density profiles to the predictions of an analytic model for the profile, obtained from the particle continuity equations for electrons and deuterium atoms. In its range of validity (edge temperature between 40-500 eV), the analytic model quantitatively predicts the observed decrease of the width as the pedestal density increases, the observed strong increase of the gradient of the density as the pedestal density increases and the observation that L-mode and H-mode profiles with the same pedestal density have very similar shapes. The width of the density barrier, measured from the edge of the electron temperature barrier, is the lower limit for the observed width of the temperature barrier. These results support the hypothesis that particle fueling provides the dominant control for the size of the H-mode transport barrier. (author)

  4. Functioning of the Cartogam portable gamma camera in a photon counting mode (this development is performed at CEA in the framework of the B01-05 common interest program between CEA and COGEMA

    International Nuclear Information System (INIS)

    Gal, O.; Dessus, B.; Laine, F.; Jean, F.; Leveque, C.

    2001-01-01

    The CARTOGAM portable gamma camera, which is particularly compact (15 Kg in mass, including the shield, 8 cm in diameter), has been developed for gamma imaging applications in nuclear facilities. The detector is composed of a CsI(Tl) scintillator, an image intensifier and a CCD matrix. The ordinary mode for image acquisition with such a detector is an integrating mode: signal accumulated in the CCD pixels is read at the end of the exposure time, or even periodically with a summation in a PC memory. The main sources of noise in that mode are the photo-cathode thermo-electronic emission and the CCD leaking pixels. We have developed an alternative acquisition mode based on a morphological processing of the elementary images at the video frequency (25 images/s). In that mode, gamma events are individually identified and the noise due to isolated thermo-electrons or white pixels is (almost) completely removed, thus leading to an important gain in camera sensitivity. We present here experimental results obtained in this photon counting mode concerning SNR, spatial resolution, saturation limit in dose rate, sensitivity and comparison with the integrating mode. We present also a short analysis of the problem of measuring the SNR in practice in such images. (author)

  5. Multi-control modes for a master-slave manipulator with different configurations and its maneuverability

    International Nuclear Information System (INIS)

    Matsuhira, Nobuto; Asakura, Makoto; Bamba, Hiroyuki

    1995-01-01

    The new master-slave control method is proposed on multi-control modes for a master-slave manipulator with different configurations. A virtual internal model following control is applied to position symmetrical bilateral control. In our method, a master-slave control mode (MS-mode), a joystick control mode (JS-mode), a master arm offset mode (OM-mode), and a servo hold mode (LK-mode) are able to be realized by operating the desired output values of the virtual internal models in a common control algorithm. There is compliant characteristic between the master and slave models. In the result of evaluation experiments between the MS-mode and the JS-mode, although the MS-mode is superior to the JS-mode in manipulating a fine task, our JS-mode is found to be useful to carry out such a task compared with a conventional JS-mode which only directs the rates for the slave arm. In the JS-mode, the slave arm moves to the position where the reaction force of the slave arm and the operating force of the master arm are balanced. Thus, it is possible either to control an overload for an object and to control the contact force. The validity of the proposed method is verified. (author)

  6. Operational test report for the AY-102 Enraf densitometer control and acquisition system

    International Nuclear Information System (INIS)

    Huber, J.H.

    1998-01-01

    On June 2 through June 10, 1998, the AY-102 Tank Densitometer Control and Acquisition System was operationally tested per OTP-320-01 O Revision A-O. The test was performed at the Department of Energy's Hanford Site, 200 East Area, 241-AY Tank Farm. The test validated the functionality of the Enraf 854 ATG Densitometer Gauge and Enraf Control Panel software for use by project W-320, Waste Retrieval Sluicing System (WRSS). The purpose of the test procedure was two fold: (1) to verify the functionality of the Enraf 854 ATG as a Densitometer and (2) to verify the functionality of the Enraf Control Panel Software density acquisition routines. The densitometer was previously acceptance tested per HNF-SD-WM-ATP-077. The software was previously acceptance tested per HNF-1991

  7. The effect of acquisition interval and spatial resolution on dynamic cardiac imaging with a stationary SPECT camera

    International Nuclear Information System (INIS)

    Roberts, J; Maddula, R; Clackdoyle, R; DiBella, E; Fu, Z

    2007-01-01

    The current SPECT scanning paradigm that acquires images by slow rotation of multiple detectors in body-contoured orbits around the patient is not suited to the rapid collection of tomographically complete data. During rapid image acquisition, mechanical and patient safety constraints limit the detector orbit to circular paths at increased distances from the patient, resulting in decreased spatial resolution. We consider a novel dynamic rotating slant-hole (DyRoSH) SPECT camera that can collect full tomographic data every 2 s, employing three stationary detectors mounted with slant-hole collimators that rotate at 30 rpm. Because the detectors are stationary, they can be placed much closer to the patient than is possible with conventional SPECT systems. We propose that the decoupling of the detector position from the mechanics of rapid image acquisition offers an additional degree of freedom which can be used to improve accuracy in measured kinetic parameter estimates. With simulations and list-mode reconstructions, we consider the effects of different acquisition intervals on dynamic cardiac imaging, comparing a conventional three detector SPECT system with the proposed DyRoSH SPECT system. Kinetic parameters of a two-compartment model of myocardial perfusion for technetium-99m-teboroxime were estimated. When compared to a conventional SPECT scanner for the same acquisition periods, the proposed DyRoSH system shows equivalent or reduced bias or standard deviation values for the kinetic parameter estimates. The DyRoSH camera with a 2 s acquisition period does not show any improvement compared to a DyRoSH camera with a 10 s acquisition period

  8. The effect of acquisition interval and spatial resolution on dynamic cardiac imaging with a stationary SPECT camera

    Science.gov (United States)

    Roberts, J.; Maddula, R.; Clackdoyle, R.; Di Bella, E.; Fu, Z.

    2007-08-01

    The current SPECT scanning paradigm that acquires images by slow rotation of multiple detectors in body-contoured orbits around the patient is not suited to the rapid collection of tomographically complete data. During rapid image acquisition, mechanical and patient safety constraints limit the detector orbit to circular paths at increased distances from the patient, resulting in decreased spatial resolution. We consider a novel dynamic rotating slant-hole (DyRoSH) SPECT camera that can collect full tomographic data every 2 s, employing three stationary detectors mounted with slant-hole collimators that rotate at 30 rpm. Because the detectors are stationary, they can be placed much closer to the patient than is possible with conventional SPECT systems. We propose that the decoupling of the detector position from the mechanics of rapid image acquisition offers an additional degree of freedom which can be used to improve accuracy in measured kinetic parameter estimates. With simulations and list-mode reconstructions, we consider the effects of different acquisition intervals on dynamic cardiac imaging, comparing a conventional three detector SPECT system with the proposed DyRoSH SPECT system. Kinetic parameters of a two-compartment model of myocardial perfusion for technetium-99m-teboroxime were estimated. When compared to a conventional SPECT scanner for the same acquisition periods, the proposed DyRoSH system shows equivalent or reduced bias or standard deviation values for the kinetic parameter estimates. The DyRoSH camera with a 2 s acquisition period does not show any improvement compared to a DyRoSH camera with a 10 s acquisition period.

  9. Microtearing modes

    International Nuclear Information System (INIS)

    Garbet, X.; Mourgues, F.; Samain, A.; Zou, X.

    1990-01-01

    A serious degradation of confinement with additional heating is commonly observed on most tokamaks. The microtearing modes could provide an explanation for this experimental fact. They are driven linearly unstable by diamagnetism in collisional regimes, but it may be shown that the collisions in non linear regimes provide a small diffusion coefficient which can be only significant at the plasme edge. In the bulk of the plasma, the microtearing turbulence could play a basic role if it is unstable in the collisionless regime. While it is linearly stable without collisions, it could be driven unstable in realistic regimes by the radial diffusion it induces. To study this effect, we have used a model where the non linear action of the modes on a given helicity component is represented by a diffusion operator. They are found unstable for reasonable β p =2μ o nT/B 2 p , with a special radial profile of the potential vector A. The problem arises the validity of this model where non linearities in the trajectories behaviour are replaced by the diffusion which broadens resonances. To test this procedure, we calculate the actual electron distribution function when it is determined by the ergodicity of the field lines. We compute the correlations of the distribution function with the magnetic perturbation and compare them with the analytical expressions derived from the resonance broadening model. (author) 3 refs., 2 figs

  10. Building a Validity Argument for the Test of English as a Foreign Language™

    CERN Document Server

    Chapelle, Carol A; Jamieson, Joan M

    2007-01-01

    Building a Validity Argument for the Test of English as a Foreign Language™ is distinctive in its attempt to develop a coherent story of the rationale for a test or its revision, explain the research and development process, and provide the results of the validation process. This volume is particularly relevant for professionals and graduate students in educational measurement, applied linguistics, and second language acquisition as well as anyone interested in assessment issues.

  11. IT-based Value Creation in Serial Acquisitions

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Yetton, Philip

    2013-01-01

    serial acquirers realize IT-based value, we integrate and model the findings on individual acquisitions from the extant literature, and extend that model to explain the effects of sequential acquisitions in a growth-by-acquisition strategy. This extended model, drawing on the Resource-Based Theory......The extant research on post-acquisition IT integration analyzes how acquirers realize IT-based value in individual acquisitions. However, serial acquirers make 60% of acquisitions. These acquisitions are not isolated events, but are components in growth-by-acquisition programs. To explain how...

  12. Adaptive sliding mode control of tri-layer conjugated polymer actuators

    International Nuclear Information System (INIS)

    Wang, Xiangjiang; Alici, Gursel; Nguyen, Chuc Huu

    2013-01-01

    This paper proposes an adaptive sliding mode control methodology to enhance the positioning ability of conducting polymer actuators typified by tri-layer conjugated polymer actuators. This is motivated by the search for an effective control strategy to command such actuators to a desired configuration in the presence of parametric uncertainties and unmodeled disturbances. After analyzing the stability of the adaptive sliding mode control system, experiments were conducted to demonstrate its satisfactory tracking ability, based on a series of experimental results. Implementation of the control law requires a valid model of the conducting polymer actuator and boundaries of the uncertainties and disturbances. Based on the theoretical and experimental results presented, the adaptive sliding mode control methodology is very attractive in the field of smart actuators which contain significant uncertainties and disturbances. (paper)

  13. 48 CFR 970.2301 - Sustainable acquisition.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Sustainable acquisition. 970.2301 Section 970.2301 Federal Acquisition Regulations System DEPARTMENT OF ENERGY AGENCY..., Renewable Energy Technologies, Occupational Safety and Drug-Free Work Place 970.2301 Sustainable acquisition...

  14. Characterization and Evaluation of 600 V Range Devices for Active Power Factor Correction in Boundary and Continuous Conduction Modes

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Petersen, Lars Press; Andersen, Michael A. E.

    2015-01-01

    Traditional characterization of semiconductors switching dynamics is performed based on clamped inductive load measurements using the double pulse tester (DPT) configuration. This approach is valid for converters operating in continuous conduction mode (CCM), however in boundary conduction mode...

  15. Sensitivity estimation in time-of-flight list-mode positron emission tomography.

    Science.gov (United States)

    Herraiz, J L; Sitek, A

    2015-11-01

    An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

  16. Sensitivity estimation in time-of-flight list-mode positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz, J. L. [Madrid-MIT M+Visión Consortium, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 and Grupo de Física Nuclear, Departamento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Madrid 28040 (Spain); Sitek, A., E-mail: sarkadiu@gmail.com [Center for Advanced Medical Imaging Sciences, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2015-11-15

    Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

  17. Point-and-stare operation and high-speed image acquisition in real-time hyperspectral imaging

    Science.gov (United States)

    Driver, Richard D.; Bannon, David P.; Ciccone, Domenic; Hill, Sam L.

    2010-04-01

    The design and optical performance of a small-footprint, low-power, turnkey, Point-And-Stare hyperspectral analyzer, capable of fully automated field deployment in remote and harsh environments, is described. The unit is packaged for outdoor operation in an IP56 protected air-conditioned enclosure and includes a mechanically ruggedized fully reflective, aberration-corrected hyperspectral VNIR (400-1000 nm) spectrometer with a board-level detector optimized for point and stare operation, an on-board computer capable of full system data-acquisition and control, and a fully functioning internal hyperspectral calibration system for in-situ system spectral calibration and verification. Performance data on the unit under extremes of real-time survey operation and high spatial and high spectral resolution will be discussed. Hyperspectral acquisition including full parameter tracking is achieved by the addition of a fiber-optic based downwelling spectral channel for solar illumination tracking during hyperspectral acquisition and the use of other sensors for spatial and directional tracking to pinpoint view location. The system is mounted on a Pan-And-Tilt device, automatically controlled from the analyzer's on-board computer, making the HyperspecTM particularly adaptable for base security, border protection and remote deployments. A hyperspectral macro library has been developed to control hyperspectral image acquisition, system calibration and scene location control. The software allows the system to be operated in a fully automatic mode or under direct operator control through a GigE interface.

  18. Acquisitions by EMNCs in Developed Markets

    DEFF Research Database (Denmark)

    Rabbiosi, Larissa; Elia, Stefano; Bertoni, Fabio

    2012-01-01

    Building on an organisational learning perspective, we argue that emerging market firms’ international experience and home-country characteristics are core sources of learning. Furthermore, we argue that these factors constitute important determinants of emerging market firms’ acquisition behaviour...... in developed countries (south-north acquisitions). We test our hypotheses on a sample of 808 south-north acquisitions. The acquisitions were undertaken in Europe, Japan and North America (Canada and the US) between 1999 and 2008 by firms from the emerging economies of Brazil, Russia, India and China....... As suggested by the internationalisation process model, our results show that emerging market firms undertake acquisitions in developed countries in an incremental fashion. Acquisition experience in developed markets increases the likelihood of exploitative expansion, while acquisition experience in developing...

  19. Improving Acquisition Outcomes with Contextual Ambidexterity

    DEFF Research Database (Denmark)

    Meglio, Olimpia; King, David R.; Risberg, Annette

    2015-01-01

    The results of research on mergers and acquisitions often point to a need to improve acquisition outcomes and lessen the organizational turmoil that can often follow integration efforts. We assert that viewing acquisition integration through the lens of contextual ambidexterity may improve...... acquisition outcomes in two ways: by providing an integrated solution to the economic and social tensions in acquisitions, and by enabling managers to effectively confront the competing needs of task and human integration. We also posit that by building on contextual ambidexterity, we can extend...... the possibilities for both research and practice regarding task and human integration in acquisitions. We also emphasize the role of an integration manager and integration mechanisms in enabling contextual ambidexterity for successful acquisition integration. Finally, we identify implications for research...

  20. Possibility of observation of polaron normal modes at the far-infrared spectrum of acetanilide and related organics

    Science.gov (United States)

    Kalosakas, G.; Aubry, S.; Tsironis, G. P.

    1998-10-01

    We use a stationary and normal mode analysis of the semiclassical Holstein model in order to connect the low-frequency linear polaron modes to low-lying far-infrared lines of the acetanilide spectrum and through parameter fitting we comment on the validity of the polaron results in this system.

  1. Acquisition of HPLC-Mass Spectrometer

    Science.gov (United States)

    2015-08-18

    31-Jan-2015 Approved for Public Release; Distribution Unlimited Final Report: Acquisition of HPLC -Mass Spectrometer The views, opinions and/or findings...published in peer-reviewed journals: Final Report: Acquisition of HPLC -Mass Spectrometer Report Title The acquisition of the mass spectrometer has been a

  2. Risk analysis of analytical validations by probabilistic modification of FMEA.

    Science.gov (United States)

    Barends, D M; Oldenhof, M T; Vredenbregt, M J; Nauta, M J

    2012-05-01

    Risk analysis is a valuable addition to validation of an analytical chemistry process, enabling not only detecting technical risks, but also risks related to human failures. Failure Mode and Effect Analysis (FMEA) can be applied, using a categorical risk scoring of the occurrence, detection and severity of failure modes, and calculating the Risk Priority Number (RPN) to select failure modes for correction. We propose a probabilistic modification of FMEA, replacing the categorical scoring of occurrence and detection by their estimated relative frequency and maintaining the categorical scoring of severity. In an example, the results of traditional FMEA of a Near Infrared (NIR) analytical procedure used for the screening of suspected counterfeited tablets are re-interpretated by this probabilistic modification of FMEA. Using this probabilistic modification of FMEA, the frequency of occurrence of undetected failure mode(s) can be estimated quantitatively, for each individual failure mode, for a set of failure modes, and the full analytical procedure. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Design of EEG Signal Acquisition System Using Arduino MEGA1280 and EEGAnalyzer

    Directory of Open Access Journals (Sweden)

    Saptono Debyo

    2016-01-01

    Full Text Available This study integrates the hardware circuit design and software development to achieve a 16 channels Electroencephalogram (EEG system for Brain Computer Interface (BCI applications. Signals obtained should be strong enough amplitude that is usually expressed in units of millivolts and reasonably clean of noise that appears when the data acquisition process. The process of data acquisition consists of two stages are the acquisition of the original EEG signal can be done by the active electrode with an instrumentation amplifier or a preamplifier and processing the signal to get better signals with improved signal quality by removing noise using filters with IC OPAMP. The design of a preamplifier with high common-mode rejection ratio and high signal-to-noise ratio is very important. Moreover, the friction between the electrode pads and the skin as well as the design of dual power supply. Designs used single-power AC-coupled circuit, which effectively reduces the DC bias and improves the error caused by the effects of part errors. At the same time, the digital way is applied to design the adjustable amplification and filter function, which can design for different EEG frequency bands. The next step, those EEG signals received by the microcontroller through a port Analog to Digital Converter (ADC that integrated and converted into digital signals and stored in the RAM of microcontroller which simultaneously at 16 ports in accordance with the minimal number of points of data collection on the human scalp. Implementation results have shown the series of acquisitions to work properly so that it can be displayed EEG signals via software EEGAnalyzer.

  4. Spatial-mode switchable ring fiber laser based on low mode-crosstalk all-fiber mode MUX/DEMUX

    Science.gov (United States)

    Ren, Fang; Yu, Jinyi; Wang, Jianping

    2018-05-01

    We report an all-fiber ring laser that emits linearly polarized (LP) modes based on the intracavity all-fiber mode multiplexer/demultiplexer (MUX/DEMUX). Multiple LP modes in ring fiber laser are generated by taking advantage of mode MUX/DEMUX. The all-fiber mode MUX/DEMUX are composed of cascaded mode-selective couplers (MSCs). The output lasing mode of the ring fiber laser can be switched among the three lowest-order LP modes by employing combination of a mode MUX and a simple N × 1 optical switch. The slope efficiencies, optical spectra and mode profiles are measured.

  5. Accelerating Magnetic Resonance Fingerprinting (MRF) using t-Blipped Simultaneous Multi-Slice (SMS) acquisition

    Science.gov (United States)

    Ye, Huihui; Ma, Dan; Jiang, Yun; Cauley, Stephen F.; Du, Yiping; Wald, Lawrence L.; Griswold, Mark A.; Setsompop, Kawin

    2015-01-01

    Purpose We incorporate Simultaneous Multi-Slice (SMS) acquisition into MR Fingerprinting (MRF) to accelerate the MRF acquisition. Methods The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the signal from different simultaneously excited slices are encoded with different phases without disturbing the signal evolution. Further, by varying the Gz blip area and/or polarity as a function of TR, the slices’ differential phase can also be made to vary as a function of time. For reconstruction of t-Blipped SMS-MRF data, we demonstrate a combined slice-direction SENSE and modified dictionary matching method. Results In Monte Carlo simulation, the parameter mapping from Multi-band factor (MB)=2 t-Blipped SMS-MRF shows good accuracy and precision when compared to results from reference conventional MRF data with concordance correlation coefficients (CCC) of 0.96 for T1 estimates and 0.90 for T2 estimates. For in vivo experiments, T1 and T2 maps from MB=2 t-Blipped SMS-MRF have a high agreement with ones from conventional MRF. Conclusions The MB=2 t-Blipped SMS-MRF acquisition/reconstruction method has been demonstrated and validated to provide more rapid parameter mapping in the MRF framework. PMID:26059430

  6. Acquisition system for the CLIC Module

    CERN Document Server

    Vilalte, Sebastien

    2011-01-01

    The status of R&D activities for CLIC module acquisition are discussed [1]. LAPP is involved in the design of the local CLIC module acquisition crate, described in the document Study of the CLIC Module Front-End Acquisition and Evaluation Electronics [2]. This acquisition system is a project based on a local crate, assigned to the CLIC module, including several mother boards. These motherboards are foreseen to hold mezzanines dedicated to the different subsystems. This system has to work in radiation environment. LAPP is involved in the development of Drive Beam stripline position monitors read-out, described in the document Drive Beam Stripline BPM Electronics and Acquisition [3]. LAPP also develops a generic acquisition mezzanine that allows to perform all-around acquisition and components tests for drive beam stripline BPM read-out.

  7. A real-time data acquisition and elaboration system for instabilities control in the FTU tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Alessi, E., E-mail: alessi@ifp.cnr.it [Associazione EURATOM-ENEA, IFP-CNR, Milano (Italy); Boncagni, L. [Associazione EURATOM-ENEA, C.R. Frascati (Italy); Galperti, C.; Marchetto, C.; Nowak, S.; Sozzi, C. [Associazione EURATOM-ENEA, IFP-CNR, Milano (Italy); Apruzzese, G. [Associazione EURATOM-ENEA, C.R. Frascati (Italy); Bin, W. [Associazione EURATOM-ENEA, IFP-CNR, Milano (Italy); Belli, F.; Botrugno, A. [Associazione EURATOM-ENEA, C.R. Frascati (Italy); Bruschi, A.; Cirant, S. [Associazione EURATOM-ENEA, IFP-CNR, Milano (Italy); D' Antona, G.; Davoudi, M. [Politecnico di Milano, Dipartimento di Elettrotecnica (Italy); Figini, L. [Associazione EURATOM-ENEA, IFP-CNR, Milano (Italy); Ferrero, R. [Politecnico di Milano, Dipartimento di Elettrotecnica (Italy); Gabellieri, L. [Associazione EURATOM-ENEA, C.R. Frascati (Italy); Garavaglia, S.; Granucci, G. [Associazione EURATOM-ENEA, IFP-CNR, Milano (Italy); Grosso, A. [Associazione EURATOM-ENEA, C.R. Frascati (Italy); and others

    2013-08-21

    A real-time data acquisition and elaboration system is being implemented to control the new ECH launcher recently installed at FTU (Frascati Tokamak Upgrade). The system is aimed at controlling different kinds of magnetohydrodynamic instabilities, in particular the deleterious 3/2 and 2/1 (neoclassical) tearing modes, (N)TM, and the saw teeth period in order to prevent the seeding of NTMs. The complete system is presented here together with preliminary offline and real-time tests. © 2001 Elsevier Science. All rights reserved.

  8. First Language Acquisition and Teaching

    Science.gov (United States)

    Cruz-Ferreira, Madalena

    2011-01-01

    "First language acquisition" commonly means the acquisition of a single language in childhood, regardless of the number of languages in a child's natural environment. Language acquisition is variously viewed as predetermined, wondrous, a source of concern, and as developing through formal processes. "First language teaching" concerns schooling in…

  9. Making Acquisition Measurable

    Science.gov (United States)

    2011-04-30

    Corporation. All rights reserved End Users Administrator/ Maintainer (A/M) Subject Matter Expert ( SME ) Trainer/ Instructor Manager, Evaluator, Supervisor... CMMI ) - Acquisition (AQ) © 2011 The MITRE Corporation. All rights reserved 13 CMMI -Development Incremental iterative development (planning & execution...objectives Constructing games highlighting particular aspects of proposed CCOD® acquisition, and conducting exercises with Subject Matter Experts ( SMEs

  10. Data acquisition in modeling using neural networks and decision trees

    Directory of Open Access Journals (Sweden)

    R. Sika

    2011-04-01

    Full Text Available The paper presents a comparison of selected models from area of artificial neural networks and decision trees in relation with actualconditions of foundry processes. The work contains short descriptions of used algorithms, their destination and method of data preparation,which is a domain of work of Data Mining systems. First part concerns data acquisition realized in selected iron foundry, indicating problems to solve in aspect of casting process modeling. Second part is a comparison of selected algorithms: a decision tree and artificial neural network, that is CART (Classification And Regression Trees and BP (Backpropagation in MLP (Multilayer Perceptron networks algorithms.Aim of the paper is to show an aspect of selecting data for modeling, cleaning it and reducing, for example due to too strong correlationbetween some of recorded process parameters. Also, it has been shown what results can be obtained using two different approaches:first when modeling using available commercial software, for example Statistica, second when modeling step by step using Excel spreadsheetbasing on the same algorithm, like BP-MLP. Discrepancy of results obtained from these two approaches originates from a priorimade assumptions. Mentioned earlier Statistica universal software package, when used without awareness of relations of technologicalparameters, i.e. without user having experience in foundry and without scheduling ranks of particular parameters basing on acquisition, can not give credible basis to predict the quality of the castings. Also, a decisive influence of data acquisition method has been clearly indicated, the acquisition should be conducted according to repetitive measurement and control procedures. This paper is based on about 250 records of actual data, for one assortment for 6 month period, where only 12 data sets were complete (including two that were used for validation of neural network and useful for creating a model. It is definitely too

  11. Inertial and viscous effects in the non linear growth of the tearing mode

    International Nuclear Information System (INIS)

    Edery, D.; Frey, M.; Tagger, M.; Soule, J.L.; Pellat, R.; Bussac, M.N.; Somon, J.P.

    1982-08-01

    The non linear self similar Tearing mode solution of Rutherford is revisited. We compute explicitly the stream function for the plasma flow including inertia, convection and viscosity. In all cases, Rutherford's solution is asymptotically valid

  12. 76 FR 68044 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-54; Small Entity Compliance Guide

    Science.gov (United States)

    2011-11-02

    ... Acquisition Circular 2005-54; Small Entity Compliance Guide AGENCY: Department of Defense (DoD), General... Federal Acquisition Circular (FAC) 2005-54, which amend the Federal Acquisition Regulation (FAR... (FAR Case 2009-006) This final rule amends the FAR to implement Executive Order (E.O.) 13494, Economy...

  13. 75 FR 19179 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-41; Small Entity Compliance Guide

    Science.gov (United States)

    2010-04-13

    ... Acquisition Circular 2005-41; Small Entity Compliance Guide AGENCIES: Department of Defense (DoD), General... Federal Acquisition Circular (FAC) 2005-41 which amends the Federal Acquisition Regulation (FAR... projects where the total cost to the Government is $25 million or more in order to promote economy and...

  14. Indexing mergers and acquisitions

    OpenAIRE

    Gang, Jianhua; Guo, Jie (Michael); Hu, Nan; Li, Xi

    2017-01-01

    We measure the efficiency of mergers and acquisitions by putting forward an index (the ‘M&A Index’) based on stochastic frontier analysis. The M&A Index is calculated for each takeover deal and is standardized between 0 and 1. An acquisition with a higher index encompasses higher efficiency. We find that takeover bids with higher M&A Indices are more likely to succeed. Moreover, the M&A Index shows a strong and positive relation with the acquirers’ post-acquisition stock perfo...

  15. 75 FR 14057 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-40; Introduction

    Science.gov (United States)

    2010-03-23

    ... the Civilian Agency Acquisition Council and the Defense Acquisition Regulations Council (Councils) in..., consider all the information in FAPIIS and PPIRS when making a responsibility determination, and notify the... appropriate for the official's consideration; and Enter a non-responsibility determination into FAPIIS. The...

  16. 75 FR 53127 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-45; Introduction

    Science.gov (United States)

    2010-08-30

    ... summarizes the Federal Acquisition Regulation (FAR) rules agreed to by the Civilian Agency Acquisition... Chambers. Cost or Pricing Data. III American Recovery 2009-008 Davis. and Reinvestment Act of 2009 (the Recovery Act)-- Buy American Requirements for Construction Materials. SUPPLEMENTARY INFORMATION: Summaries...

  17. Mode transition coordinated control for a compound power-split hybrid car

    Science.gov (United States)

    Wang, Chen; Zhao, Zhiguo; Zhang, Tong; Li, Mengna

    2017-03-01

    With a compound power-split transmission directly connected to the engine in hybrid cars, dramatic fluctuations in engine output torque result in noticeable jerks when the car is in mode transition from electric drive mode to hybrid drive mode. This study designed a mode transition coordinated control strategy, and verified that strategy's effectiveness with both simulations and experiments. Firstly, the mode transition process was analyzed, and ride comfort issues during the mode transition process were demonstrated. Secondly, engine ripple torque was modeled using the measured cylinder pumping pressure when the engine was not in operation. The complete dynamic plant model of the power-split hybrid car was deduced, and its effectiveness was validated by a comparison of experimental and simulation results. Thirdly, a coordinated control strategy was designed to determine the desired engine torque, motor torque, and the moment of fuel injection. Active damping control with two degrees of freedom, based on reference output shaft speed estimation, was designed to mitigate driveline speed oscillations. Carrier torque estimation based on transmission kinematics and dynamics was used to suppress torque disturbance during engine cranking. The simulation and experimental results indicate that the proposed strategy effectively suppressed vehicle jerks and improved ride comfort during mode transition.

  18. A validated stability-indicating LC method for the separation of enantiomer and potential impurities of Linezolid using polar organic mode

    Directory of Open Access Journals (Sweden)

    T. Satyanarayana Raju

    2012-08-01

    Full Text Available Although a number of methods are available for evaluating Linezolid and its possible impurities, a common method for separation if its potential impurities, degradants and enantiomer in a single method with good efficiency remain unavailable. With the objective of developing an advanced method with shorter runtimes, a simple, precise, accurate stability-indicating LC method was developed for the determination of purity of Linezolid drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. This method is capable of separating all the related substances of Linezolid along with the chiral impurity. This method can also be used for the estimation of assay of Linezolid in drug substance as well as in drug product. The method was developed using Chiralpak IA (250 mm×4.6 mm, 5 μm column. A mixture of acetonitrile, ethanol, n-butyl amine and trifluoro acetic acid in 96:4:0.10:0.16 (v/v/v/v ratio was used as a mobile phase. The eluted compounds were monitored at 254 nm. Linezolid was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per International Conference on Harmonization (ICH guidelines with respect to specificity, limit of detection, limit of quantification, precision, linearity, accuracy, robustness and system suitability. Keywords: HPLC, Linezolid, Validation, Polar organic mode, Stability-indicating

  19. Site characterization and validation - validation drift fracture data, stage 4

    International Nuclear Information System (INIS)

    Bursey, G.; Gale, J.; MacLeod, R.; Straahle, A.; Tiren, S.

    1991-08-01

    This report describes the mapping procedures and the data collected during fracture mapping in the validation drift. Fracture characteristics examined include orientation, trace length, termination mode, and fracture minerals. These data have been compared and analysed together with fracture data from the D-boreholes to determine the adequacy of the borehole mapping procedures and to assess the nature and degree of orientation bias in the borehole data. The analysis of the validation drift data also includes a series of corrections to account for orientation, truncation, and censoring biases. This analysis has identified at least 4 geologically significant fracture sets in the rock mass defined by the validation drift. An analysis of the fracture orientations in both the good rock and the H-zone has defined groups of 7 clusters and 4 clusters, respectively. Subsequent analysis of the fracture patterns in five consecutive sections along the validation drift further identified heterogeneity through the rock mass, with respect to fracture orientations. These results are in stark contrast to the results form the D-borehole analysis, where a strong orientation bias resulted in a consistent pattern of measured fracture orientations through the rock. In the validation drift, fractures in the good rock also display a greater mean variance in length than those in the H-zone. These results provide strong support for a distinction being made between fractures in the good rock and the H-zone, and possibly between different areas of the good rock itself, for discrete modelling purposes. (au) (20 refs.)

  20. Validation of CryoSat-2 SAR mode based lake levels

    DEFF Research Database (Denmark)

    Nielsen, Karina; Stenseng, Lars; Andersen, Ole Baltazar

    2015-01-01

    Lake level serve as an important indicator of the climate and continuous measurements are therefore essential. Satellite radar altimetry has now been used successfully for more than two decades to measure lake level as an addition to gauge measurements. The technique has, due to the large footprint...... with water levels obtained from Envisat. We find that the along-track precision of the mean based on CryoSat-2 is a few centimeter, even for the small lakes, which is a significant improvement compared to previous missions such as Envisat. When validating against gauge data we find RMS values of differences...

  1. On a separating method for mixed-modes crack growth in wood material using image analysis

    Science.gov (United States)

    Moutou Pitti, R.; Dubois, F.; Pop, O.

    2010-06-01

    Due to the complex wood anatomy and the loading orientation, the timber elements are subjected to a mixed-mode fracture. In these conditions, the crack tip advance is characterized by mixed-mode kinematics. In order to characterize the fracture process function versus the loading orientation, a new mixed-mode crack growth timber specimen is proposed. In the present paper, the design process and the experimental validation of this specimen are proposed. Using experimental results, the energy release rate is calculated for several modes. The calculi consist on the separation of each fracture mode. The design of the specimen is based on the analytical approach and numerical simulation by finite element method. The specimen particularity is the stability of the crack propagation under a force control.

  2. Components for the data acquisition system of the ATLAS testbeams 1996

    International Nuclear Information System (INIS)

    Caprini, M; Niculescu, Michaela

    1997-01-01

    ATLAS is one of the experiments developed at CERN for the Large Hadron Collider. For the sub-detector testbeams a data acquisition system (DAQ) was designed. The Bucharest group is a member of the ATLAS DAQ collaboration and contributed to the development of some components of the testbeam DAQ: -read-out modules for standalone and combined test-beams; - readout module for the liquid argon detector; - run control graphical user interface; - central data recording system. The readout module is able to acquire data event by event from the detector electronics and is based on a Finite State Machine (FSM) incorporating a general scheme for the calibration procedure. The FSM allows detectors to take data either in standalone mode, with local control and recording, or in combined mode together with other sub-detectors, with a very easy switching between the two different configurations. The readout module for the liquid argon detector is written as a data flow element which takes raw data and creates a formatted event. At initialization stage the run and detector parameters are read from the Run Control Parameters database. Then the state changes are driven by three interrupt signals (Start of Burst, Trigger, End of Burst) generated by hardware. In calibration mode at each trigger the event is built (calibration data are taken outside the beam) and then the conditions for the next calibration trigger are prepared (DAQ values, delays, pulsers). The graphical user interface is designed to be used for the control of the data acquisition system. The interface provides a global experiment panel for the activation and navigation in all the command and display panels. The user can start, stop or change the state of the system, obtain the most important information about the whole system states and activate other service programs in order to select parameters, databases and to display information about the evolution of the system. Central data recording system lays on the client

  3. Quantitative heart scintigraphy using Fourier analysis of unformated list mode data

    International Nuclear Information System (INIS)

    Knopp, R.; Schmidt, H.; Reichmann, K.; Biersack, H.J.; Winkler, C.

    1981-01-01

    Fourier transformation in radioventriculography is used for smoothing of the left ventricular volume curves as well as for the evaluating of regional wall motions by means of amplitude and phase imaging. Our new method is based on Fourier transformation from unformatted list mode data, pixel by pixel. Determination of the Fourier coefficients of 4 harmonic waves as a maximum is performed and frame sequences are generated by Fourier resynthesis. As main advantages of the method can be regarded a) considerable improvement of the image quality and b) substantial reduction of time needed for data acquisition. (orig.) [de

  4. Developing Acquisition IS Integration Capabilities

    DEFF Research Database (Denmark)

    Wynne, Peter J.

    2016-01-01

    An under researched, yet critical challenge of Mergers and Acquisitions (M&A), is what to do with the two organisations’ information systems (IS) post-acquisition. Commonly referred to as acquisition IS integration, existing theory suggests that to integrate the information systems successfully......, an acquiring company must leverage two high level capabilities: diagnosis and integration execution. Through a case study, this paper identifies how a novice acquirer develops these capabilities in anticipation of an acquisition by examining its use of learning processes. The study finds the novice acquirer...... applies trial and error, experimental, and vicarious learning processes, while actively avoiding improvisational learning. The results of the study contribute to the acquisition IS integration literature specifically by exploring it from a new perspective: the learning processes used by novice acquirers...

  5. Operation Modes and Control Schemes for Internet-Based Teleoperation System with Time Delay

    Institute of Scientific and Technical Information of China (English)

    曾庆军; 宋爱国

    2003-01-01

    Teleoperation system plays an important role in executing task under hazard environment. As the computer networks such as the Internet are being used as the communication channel of teleoperation system, varying time delay causes the overall system unstable and reduces the performance of transparency. This paper proposed twelve operation modes with different control schemes for teleoperation on the Internet with time delay. And an optimal operation mode with control scheme was specified for teleoperation with time delay, based on the tradeoff between passivity and transparency properties. It experimentally confirmed the validity of the proposed optimal mode and control scheme by using a simple one DOF master-slave manipulator system.

  6. Calo trigger acquisition system

    CERN Multimedia

    Franchini, Matteo

    2016-01-01

    Calo trigger acquisition system - Evolution of the acquisition system from a multiple boards system (upper, orange cables) to a single board one (below, light blue cables) where all the channels are collected in a single board.

  7. PECAN: library-free peptide detection for data-independent acquisition tandem mass spectrometry data

    Energy Technology Data Exchange (ETDEWEB)

    Ting, Ying S.; Egertson, Jarrett D.; Bollinger, James G.; Searle, Brian C.; Payne, Samuel H.; Noble, William Stafford; MacCoss, Michael J.

    2017-08-07

    Data-independent acquisition (DIA) is an emerging mass spectrometry (MS)-based technique for unbiased and reproducible measurement of protein mixtures. DIA tandem mass spectrometry spectra are often highly multiplexed, containing product ions from multiple cofragmenting precursors. Detecting peptides directly from DIA data is therefore challenging; most DIA data analyses require spectral libraries. Here we present PECECAN (http://pecan.maccosslab.org), a library-free, peptide-centric tool that robustly and accurately detects peptides directly from DIA data. PECECAN reports evidence of detection based on product ion scoring, which enables detection of low-abundance analytes with poor precursor ion signal. We demonstrate the chromatographic peak picking accuracy and peptide detection capability of PECECAN, and we further validate its detection with data-dependent acquisition and targeted analyses. Lastly, we used PECECAN to build a plasma proteome library from DIA data and to query known sequence variants.

  8. Playing at Serial Acquisitions

    NARCIS (Netherlands)

    J.T.J. Smit (Han); T. Moraitis (Thras)

    2010-01-01

    textabstractBehavioral biases can result in suboptimal acquisition decisions-with the potential for errors exacerbated in consolidating industries, where consolidators design serial acquisition strategies and fight escalating takeover battles for platform companies that may determine their future

  9. Renal stone characterization using high resolution imaging mode on a photon counting detector CT system

    Science.gov (United States)

    Ferrero, A.; Gutjahr, R.; Henning, A.; Kappler, S.; Halaweish, A.; Abdurakhimova, D.; Peterson, Z.; Montoya, J.; Leng, S.; McCollough, C.

    2017-03-01

    In addition to the standard-resolution (SR) acquisition mode, a high-resolution (HR) mode is available on a research photon-counting-detector (PCD) whole-body CT system. In the HR mode each detector consists of a 2x2 array of 0.225 mm x 0.225 mm subpixel elements. This is in contrast to the SR mode that consists of a 4x4 array of the same subelements, and results in 0.25 mm isotropic resolution at iso-center for the HR mode. In this study, we quantified ex vivo the capabilities of the HR mode to characterize renal stones in terms of morphology and mineral composition. Forty pure stones - 10 uric acid (UA), 10 cystine (CYS), 10 calcium oxalate monohydrate (COM) and 10 apatite (APA) - and 14 mixed stones were placed in a 20 cm water phantom and scanned in HR mode, at radiation dose matched to that of routine dual-energy stone exams. Data from micro CT provided a reference for the quantification of morphology and mineral composition of the mixed stones. The area under the ROC curve was 1.0 for discriminating UA from CYS, 0.89 for CYS vs COM and 0.84 for COM vs APA. The root mean square error (RMSE) of the percent UA in mixed stones was 11.0% with a medium-sharp kernel and 15.6% with the sharpest kernel. The HR showed qualitatively accurate characterization of stone morphology relative to micro CT.

  10. Choice Model and Influencing Factor Analysis of Travel Mode for Migrant Workers: Case Study in Xi’an, China

    OpenAIRE

    Hong Chen; Zuo-xian Gan; Yu-ting He

    2015-01-01

    Based on the basic theory and methods of disaggregate choice model, the influencing factors in travel mode choice for migrant workers are analyzed, according to 1366 data samples of Xi’an migrant workers. Walking, bus, subway, and taxi are taken as the alternative parts of travel modes for migrant workers, and a multinomial logit (MNL) model of travel mode for migrant workers is set up. The validity of the model is verified by the hit rate, and the hit rates of four travel modes are all great...

  11. Validation of a chiral liquid chromatography-tandem mass spectrometry method for the determination of pantoprazole in dog plasma.

    Science.gov (United States)

    Chen, Meixia; Xia, Yu; Ma, Zhiyu; Li, Liang; Zhong, Dafang; Chen, Xiaoyan

    2012-10-01

    Pantoprazole (PAN), a selective proton pump inhibitor, is used clinically as a racemic mixture for the treatment of acid-related gastrointestinal disorders. To investigate its stereoselective pharmacokinetics, a chiral liquid chromatography-tandem mass spectrometry method was developed and validated to determine the pantoprazole enantiomers in dog plasma. After liquid-liquid extraction, a baseline resolution of enantiomers was achieved on an ovomucoid column using the mobile phase of methanol:acetonitrile:10mM ammonium formate (pH 7) (10.4:2.6:87, v/v/v) at 30°C within 10min. Stable isotopically labeled (+)-d(3)-pantoprazole and (-)-d(3)-pantoprazole were used as internal standards. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode via positive atmospheric pressure chemical ionization. The method was linear in the concentration range of 20.0-10,000ng/mL for each enantiomer using 25μL of dog plasma. The lower limit of quantification (LLOQ) for each enantiomer was 20.0ng/mL. Intra- and inter-day precision ranged from 3.2% to 10.3% for (+)-pantoprazole and 3.7-10.0% for (-)-pantoprazole. Accuracy varied from -1.4% to -0.2% for (+)-pantoprazole and -1.6% to 0.8% for (-)-pantoprazole. The validated method was applied successfully for stereoselective pharmacokinetic studies of racemic pantoprazole. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Development and validation of LC-MS/MS method with multiple reactions monitoring mode for quantification of vanillin and syringaldehyde in plum brandies

    Directory of Open Access Journals (Sweden)

    Tešević Vele

    2014-01-01

    Full Text Available An ultra-performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-QqQ-MS/MS method with multiple reactions monitoring mode (MRM has been developed and validated for quantification of vanillin and syringaldehyde in plum brandy. The method showed good linearity (0.05 to 10 mgL−1 and low limits of detection and quantification (LOD and LOQ were 11.6 µgL−1 and 38.2 µgL−1 for vanillin, and 12.7 µgL−1 and 42.0 µgL−1 for syringaldehyde, respectively. The overall intra-day and inter-day variations were less than 4.21%, and the overall recovery over 93.0%. The correlation coefficients (R2 of the calibration curves were higher than 0.9999. In order to evaluate if the method is suitable for use as a routine analytical tool, in 31 Serbian plum brandy samples vanillin and syringaldehide were determined. [Projekat Ministarstva nauke Republike Srbije, br. 172053

  13. Data Acquisition System for Electron Energy Loss Coincident Spectrometers

    International Nuclear Information System (INIS)

    Zhang Chi; Yu Xiaoqi; Yang Tao

    2005-01-01

    A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension position-sensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out (FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown

  14. Validation of the Mass-Extraction-Window for Quantitative Methods Using Liquid Chromatography High Resolution Mass Spectrometry.

    Science.gov (United States)

    Glauser, Gaétan; Grund, Baptiste; Gassner, Anne-Laure; Menin, Laure; Henry, Hugues; Bromirski, Maciej; Schütz, Frédéric; McMullen, Justin; Rochat, Bertrand

    2016-03-15

    A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.

  15. Modelling live forensic acquisition

    CSIR Research Space (South Africa)

    Grobler, MM

    2009-06-01

    Full Text Available This paper discusses the development of a South African model for Live Forensic Acquisition - Liforac. The Liforac model is a comprehensive model that presents a range of aspects related to Live Forensic Acquisition. The model provides forensic...

  16. The Computer Book of the Internal Medicine Resident: competence acquisition and achievement of learning objectives.

    Science.gov (United States)

    Oristrell, J; Oliva, J C; Casanovas, A; Comet, R; Jordana, R; Navarro, M

    2014-01-01

    The Computer Book of the Internal Medicine resident (CBIMR) is a computer program that was validated to analyze the acquisition of competences in teams of Internal Medicine residents. To analyze the characteristics of the rotations during the Internal Medicine residency and to identify the variables associated with the acquisition of clinical and communication skills, the achievement of learning objectives and resident satisfaction. All residents of our service (n=20) participated in the study during a period of 40 months. The CBIMR consisted of 22 self-assessment questionnaires specific for each rotation, with items on services (clinical workload, disease protocolization, resident responsibilities, learning environment, service organization and teamwork) and items on educational outcomes (acquisition of clinical and communication skills, achievement of learning objectives, overall satisfaction). Associations between services features and learning outcomes were analyzed using bivariate and multivariate analysis. An intense clinical workload, high resident responsibilities and disease protocolization were associated with the acquisition of clinical skills. High clinical competence and teamwork were both associated with better communication skills. Finally, an adequate learning environment was associated with increased clinical competence, the achievement of educational goals and resident satisfaction. Potentially modifiable variables related with the operation of clinical services had a significant impact on the acquisition of clinical and communication skills, the achievement of educational goals, and resident satisfaction during the specialized training in Internal Medicine. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  17. Industry Relatedness and Post-Acquisition Innovative Performance

    DEFF Research Database (Denmark)

    Cefis, Elena; Marsili, Orietta; Rigamonti, Damiana

    2015-01-01

    This paper examines how characteristics of acquiring and acquired firms influence the curvilinear (inverted U-shaped) relationship between relatedness and post-acquisition innovative performance. Using a relatedness index based on industry co-occurrence in a sample of 1,736 Dutch acquisitions, we...... find that acquirer's internal R&D and acquisition experience, and the small size of acquired firms, help to reach a balance between exploration of novelty and exploitation of synergies in unrelated acquisitions, and to achieve higher post-acquisition performance. However, while the acquirer's R......&D increases flexibility in the acquisition process in presence of deviations from the optimal level of relatedness, acquisition experience may enhance rigidities....

  18. New Method to Study the Vibrational Modes of Biomolecules in the Terahertz Range Based on a Single-Stage Raman Spectrometer.

    Science.gov (United States)

    Kalanoor, Basanth S; Ronen, Maria; Oren, Ziv; Gerber, Doron; Tischler, Yaakov R

    2017-03-31

    The low-frequency vibrational (LFV) modes of biomolecules reflect specific intramolecular and intermolecular thermally induced fluctuations that are driven by external perturbations, such as ligand binding, protein interaction, electron transfer, and enzymatic activity. Large efforts have been invested over the years to develop methods to access the LFV modes due to their importance in the studies of the mechanisms and biological functions of biomolecules. Here, we present a method to measure the LFV modes of biomolecules based on Raman spectroscopy that combines volume holographic filters with a single-stage spectrometer, to obtain high signal-to-noise-ratio spectra in short acquisition times. We show that this method enables LFV mode characterization of biomolecules even in a hydrated environment. The measured spectra exhibit distinct features originating from intra- and/or intermolecular collective motion and lattice modes. The observed modes are highly sensitive to the overall structure, size, long-range order, and configuration of the molecules, as well as to their environment. Thus, the LFV Raman spectrum acts as a fingerprint of the molecular structure and conformational state of a biomolecule. The comprehensive method we present here is widely applicable, thus enabling high-throughput study of LFV modes of biomolecules.

  19. Value Creation through Acquisition Strategy: A Study of Volvo’s Acquisition by Geely

    Directory of Open Access Journals (Sweden)

    Yane Chandera

    2012-04-01

    Full Text Available This paper examines the value creation on the acquisition of Volvo Car Corp by Zhejiang Geely Holding Group. The acquisition of Volvo by Geely became an interesting topic to discuss since it was the first time in automotive industry that a Chinese company acquired an international company with a considerably high transaction amount. The paper examines the short term value creation using event study to calculate abnormal returns of each company’s stock during the announcement period and measuring the significance of the cumulative abnormal return. The findings are consistent with previous studies over the years which have shown that most acquisitions fail to add value for shareholders in the acquiring company. The paper discusses the broad managerial implications of the findings this paper discussion on marketing aspect after the acquisition by integrating two different brand perceptions.

  20. Value Creation through Acquisition Strategy: A Study of Volvo’s Acquisition by Geely

    Directory of Open Access Journals (Sweden)

    Yane Chandera

    2012-08-01

    Full Text Available This paper examines the value creation on the acquisition of Volvo Car Corp by Zhejiang Geely Holding Group. The acquisition of Volvo by Geely became an interesting topic to discuss since it was the first time in automotive industry that a Chinese company acquired an international company with a considerably high transaction amount. The paper examines the short term value creation using event study to calculate abnormal returns of each company’s stock during the announcement period and measuring the significance of the cumulative abnormal return. The findings are consistent with previous studies over the years which have shown that most acquisitions fail to add value for shareholders in the acquiring company. The paper discusses the broad managerial implications of the findings this paper discussion on marketing aspect after the acquisition by integrating two different brand perceptions.

  1. Concealed, Unobtrusive Ear-Centered EEG Acquisition: cEEGrids for Transparent EEG

    Science.gov (United States)

    Bleichner, Martin G.; Debener, Stefan

    2017-01-01

    Electroencephalography (EEG) is an important clinical tool and frequently used to study the brain-behavior relationship in humans noninvasively. Traditionally, EEG signals are recorded by positioning electrodes on the scalp and keeping them in place with glue, rubber bands, or elastic caps. This setup provides good coverage of the head, but is impractical for EEG acquisition in natural daily-life situations. Here, we propose the transparent EEG concept. Transparent EEG aims for motion tolerant, highly portable, unobtrusive, and near invisible data acquisition with minimum disturbance of a user's daily activities. In recent years several ear-centered EEG solutions that are compatible with the transparent EEG concept have been presented. We discuss work showing that miniature electrodes placed in and around the human ear are a feasible solution, as they are sensitive enough to pick up electrical signals stemming from various brain and non-brain sources. We also describe the cEEGrid flex-printed sensor array, which enables unobtrusive multi-channel EEG acquisition from around the ear. In a number of validation studies we found that the cEEGrid enables the recording of meaningful continuous EEG, event-related potentials and neural oscillations. Here, we explain the rationale underlying the cEEGrid ear-EEG solution, present possible use cases and identify open issues that need to be solved on the way toward transparent EEG. PMID:28439233

  2. Mathematical modeling analysis of regenerative solid oxide fuel cells in switching mode conditions

    Science.gov (United States)

    Jin, Xinfang; Xue, Xingjian

    A 2D transient mathematical model is developed for regenerative solid oxide cells operated in both SOFC mode and SOEC mode. The steady state performance of the model is validated using experimental results of in-house prepared NiO-YSZ/YSZ/LSM cell under different operating temperatures. The model is employed to investigate complicated multi-physics processes during the transient process of mode switching. Simulation results indicate that the trend of internal parameter distributions, including H 2/O 2/H 2O and ionic potentials, flip when the operating cell is switched from one mode to another. However, the electronic potential shows different behaviors. At H 2 electrode, electronic potential keeps at zero voltage level, while at O 2 electrode, it increases from a relatively low level in SOFC mode to a relatively high level in SOEC mode. Transient results also show that an overshooting phenomenon occurs for mass fraction distribution of water vapor at H 2 side when the operating cell switches from SOFC mode to SOEC mode. The mass fractions of O 2 and H 2 as well as charge (electrons and ions) potentials may quickly follow the operating mode changes without over-shootings. The simulation results facilitate the internal mechanism understanding for regenerative SOFCs.

  3. Force reconstruction from tapping mode force microscopy experiments

    International Nuclear Information System (INIS)

    Payam, Amir F; Martin-Jimenez, Daniel; Garcia, Ricardo

    2015-01-01

    Fast, accurate, and robust nanomechanical measurements are intensely studied in materials science, applied physics, and molecular biology. Amplitude modulation force microscopy (tapping mode) is the most established nanoscale characterization technique of surfaces for air and liquid environments. However, its quantitative capabilities lag behind its high spatial resolution and robustness. We develop a general method to transform the observables into quantitative force measurements. The force reconstruction algorithm has been deduced on the assumption that the observables (amplitude and phase shift) are slowly varying functions of the tip–surface separation. The accuracy and applicability of the method is validated by numerical simulations and experiments. The method is valid for liquid and air environments, small and large free amplitudes, compliant and rigid materials, and conservative and non-conservative forces. (paper)

  4. An Investigation of Digital Instrumentation and Control System Failure Modes

    International Nuclear Information System (INIS)

    Korsah, Kofi; Cetiner, Mustafa Sacit; Muhlheim, Michael David; Poore, Willis P. III

    2010-01-01

    A study sponsored by the Nuclear Regulatory Commission study was conducted to investigate digital instrumentation and control (DI and C) systems and module-level failure modes using a number of databases both in the nuclear and non-nuclear industries. The objectives of the study were to obtain relevant operational experience data to identify generic DI and C system failure modes and failure mechanisms, and to obtain generic insights, with the intent of using results to establish a unified framework for categorizing failure modes and mechanisms. Of the seven databases studied, the Equipment Performance Information Exchange database was found to contain the most useful data relevant to the study. Even so, the general lack of quality relative to the objectives of the study did not allow the development of a unified framework for failure modes and mechanisms of nuclear I and C systems. However, an attempt was made to characterize all the failure modes observed (i.e., without regard to the type of I and C equipment under consideration) into common categories. It was found that all the failure modes identified could be characterized as (a) detectable/preventable before failures, (b) age-related failures, (c) random failures, (d) random/sudden failures, or (e) intermittent failures. The percentage of failure modes characterized as (a) was significant, implying that a significant reduction in system failures could be achieved through improved online monitoring, exhaustive testing prior to installation, adequate configuration control or verification and validation, etc.

  5. Line optical and Auger data acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Wall, W E; Stevenson, J R [Georgia Inst. of Tech., Atlanta (USA). School of Physics

    1978-06-01

    A software/hardware package has been developed for use with an 8K DEC PDP-8/L or /I minicomputer, providing real time acquisition and manipulation of optical reflectivity, Auger, and photoemission data. Optical data and Auger or photoemission data may be acquired simultaneously. Provisions have been included for the addition of a scanning rotating ellipsometer. Synchrotron radiation from an electron storage ring has been the primary optical source. Optical reflectivity is measured using single photon counting with a ratio technique that samples a portion of the incident light with one detector and the reflected light with a second detector. Differential Auger or photoemission data is acquired using a cylindrical mirror electron energy analyzer under computer control in a signal averaging mode of operation. Direct electron distribution curves may be displayed using a numerical integration routine. Software was written in assembly language to conserve available memory; however, a modular approach was used to allow easy additions and modifications to experiments. Data arrays may be manipulated and stored as single variables.

  6. The RING and Seismic Network: Data Acquisition of Co-located Stations

    Science.gov (United States)

    Falco, L.; Avallone, A.; Cattaneo, M.; Cecere, G.; Cogliano, R.; D'Agostino, N.; D'Ambrosio, C.; D'Anastasio, E.; Selvaggi, G.

    2007-12-01

    The plate boundary between Africa and Eurasia represents an interesting geodynamical region characterized by a complex pattern of deformation. First-order scientific problems regarding the existence of rigid blocks within the plate boundary, the present-day activity of the Calabrian subduction zone and the modes of release of seismic deformation are still awaiting for a better understanding. To address these issues, the INGV (Istituto Nazionale Geofisica e Vulcanlogia) deployed a permanent, integrated and real-time monitoring GPS network (RING) all over Italy. RING is now constituted by about 120 stations. The CGPS sites, acquiring at 1Hz and 30s sampling rate, are integrated either with broad band or very broad band seismometers and accelerometers for an improved definition of the seismically active regions. Most of the sites are connected to the acquisition centre (located in Rome and duplicated in Grottaminarda) through a satellite system (VSAT), while the remaining sites transmit data by Internet and classical phone connections. The satellite data transmission and the integration with seismic instruments makes this network one of the most innovative CGPS networks in Europe. The heterogeneity of the installed instrumentation, the transmission types and the increasing number of stations needed a central monitoring and acquisition system. A central acquisition system has been developed in Grottaminarda in southern Italy. Regarding the seismic monitoring we chose to use the open source system Earthworm, developed by USGS, with which we store waveforms and implement automatic localization of the seismic events occurring in the area. As most of the GPS sites are acquired by means of Nanometrics satellite technology, we developed a specific software (GpsView), written in Java, to monitor the state of health of those CGPS. This software receives GPS data from NaqsServer (Nanometrics acquisition system) and outputs information about the sites (i.e. approx position

  7. Optimized image acquisition for breast tomosynthesis in projection and reconstruction space

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Lo, Joseph Y.; Baker, Jay A.; Samei, Ehsan

    2009-01-01

    Breast tomosynthesis has been an exciting new development in the field of breast imaging. While the diagnostic improvement via tomosynthesis is notable, the full potential of tomosynthesis has not yet been realized. This may be attributed to the dependency of the diagnostic quality of tomosynthesis on multiple variables, each of which needs to be optimized. Those include dose, number of angular projections, and the total angular span of those projections. In this study, the authors investigated the effects of these acquisition parameters on the overall diagnostic image quality of breast tomosynthesis in both the projection and reconstruction space. Five mastectomy specimens were imaged using a prototype tomosynthesis system. 25 angular projections of each specimen were acquired at 6.2 times typical single-view clinical dose level. Images at lower dose levels were then simulated using a noise modification routine. Each projection image was supplemented with 84 simulated 3 mm 3D lesions embedded at the center of 84 nonoverlapping ROIs. The projection images were then reconstructed using a filtered backprojection algorithm at different combinations of acquisition parameters to investigate which of the many possible combinations maximizes the performance. Performance was evaluated in terms of a Laguerre-Gauss channelized Hotelling observer model-based measure of lesion detectability. The analysis was also performed without reconstruction by combining the model results from projection images using Bayesian decision fusion algorithm. The effect of acquisition parameters on projection images and reconstructed slices were then compared to derive an optimization rule for tomosynthesis. The results indicated that projection images yield comparable but higher performance than reconstructed images. Both modes, however, offered similar trends: Performance improved with an increase in the total acquisition dose level and the angular span. Using a constant dose level and angular

  8. Using GPS-derived speed patterns for recognition of transport modes in adults.

    Science.gov (United States)

    Huss, Anke; Beekhuizen, Johan; Kromhout, Hans; Vermeulen, Roel

    2014-10-11

    Identification of active or sedentary modes of transport is of relevance for studies assessing physical activity or addressing exposure assessment. We assessed in a proof-of-principle study if speed as logged by GPSs could be used to identify modes of transport (walking, bicycling, and motorized transport: car, bus or train). 12 persons commuting to work walking, bicycling or with motorized transport carried GPSs for two commutes and recorded their mode of transport. We evaluated seven speed metrics: mean, 95th percentile of speed, standard deviation of the mean, rate-of-change, standardized-rate-of-change, acceleration and deceleration. We assessed which speed metric would best identify the transport mode using discriminant analyses. We applied cross validation and calculated agreement (Cohen's Kappa) between actual and derived modes of transport. Mode of transport was reliably classified whenever a person used a mode of transport for longer than one minute. Best results were observed when using the 95th percentile of speed, acceleration and deceleration (kappa 0.73). When we combined all motorized traffic into one category, kappa increased to 0.95. GPS-measured speed enable the identification of modes of transport. Given the current low costs of GPS devices and the built-in capacity of GPS tracking in most smartphones, the use of such devices in large epidemiological studies may facilitate the assessment of physical activity related to transport modes, or improve exposure assessment using automated travel mode detection.

  9. Impact of acquisition and interpretation on total inter-observer variability in echocardiography: results from the quality assurance program of the STAAB cohort study.

    Science.gov (United States)

    Morbach, Caroline; Gelbrich, Götz; Breunig, Margret; Tiffe, Theresa; Wagner, Martin; Heuschmann, Peter U; Störk, Stefan

    2018-02-14

    Variability related to image acquisition and interpretation is an important issue of echocardiography in clinical trials. Nevertheless, there is no broadly accepted standard method for quality assessment of echocardiography in clinical research reports. We present analyses based on the echocardiography quality-assurance program of the ongoing STAAB cohort study (characteristics and course of heart failure stages A-B and determinants of progression). In 43 healthy individuals (mean age 50 ± 14 years; 18 females), duplicate echocardiography scans were acquired and mutually interpreted by one of three trained sonographers and an EACVI certified physician, respectively. Acquisition (AcV), interpretation (InV), and inter-observer variability (IOV; i.e., variability between the acquisition-interpretation sequences of two different observers), were determined for selected M-mode, B-mode, and Doppler parameters. We calculated Bland-Altman upper 95% limits of absolute differences, implying that 95% of measurement differences were smaller/equal to the given value: e.g. LV end-diastolic volume (mL): 25.0, 25.0, 27.9; septal e' velocity (cm/s): 3.03, 1.25, 3.58. Further, 90, 85, and 80% upper limits of absolute differences were determined for the respective parameters. Both, acquisition and interpretation, independently and sizably contributed to IOV. As such, separate assessment of AcV and InV is likely to aid in echocardiography training and quality-assurance. Our results further suggest to routinely determine IOV in clinical trials as a comprehensive measure of imaging quality. The derived 95, 90, 85, and 80% upper limits of absolute differences are suggested as reproducibility targets of future studies, thus contributing to the international efforts of standardization in quality-assurance.

  10. Research on engineering simulator for function validating of DCS in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Liu Pengfei; Lin Meng; Hou Dong; Yang Yanhua; Chen Zhi

    2009-01-01

    An engineering simulator for the function validating of Distributed Control System in Nuclear Power Plant (NPP) was developed in this paper.In the engineering simulator, the thermal-hydraulics was modeled by Relap5, the main control system of the NPP was modeled by Matlab/Simulink, the database was built by MySQL, and the control panel was developed by the Visual Studio. NET.Data acquisition system was used to realize the real-time communication between the simulator and the real Distributed Control System in the NPP. The validating results show that the simulator can meet the requirements of validating the hardware and logic control system of DCS in NPP. (authors)

  11. Dual-cavity mode converter for a fundamental mode output in an over-moded relativistic backward-wave oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jiawei; Huang, Wenhua [Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei 230027 (China); Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Xiao, Renzhen; Bai, Xianchen; Zhang, Yuchuan; Zhang, Xiaowei; Shao, Hao; Chen, Changhua [Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Zhu, Qi [Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei 230027 (China)

    2015-03-16

    A dual-cavity TM{sub 02}–TM{sub 01} mode converter is designed for a dual-mode operation over-moded relativistic backward-wave oscillator. With the converter, the fundamental mode output is achieved. Particle-in-cell simulation shows that the efficiency of beam-wave conversion was over 46% and a pureTM{sub 01} mode output was obtained. Effects of end reflection provided by the mode converter were studied. Adequate TM{sub 01} mode feedback provided by the converter enhances conversion efficiency. The distance between the mode converter and extraction cavity critically affect the generation of microwaves depending on the reflection phase of TM{sub 01} mode feedback.

  12. Dual-cavity mode converter for a fundamental mode output in an over-moded relativistic backward-wave oscillator

    International Nuclear Information System (INIS)

    Li, Jiawei; Huang, Wenhua; Xiao, Renzhen; Bai, Xianchen; Zhang, Yuchuan; Zhang, Xiaowei; Shao, Hao; Chen, Changhua; Zhu, Qi

    2015-01-01

    A dual-cavity TM 02 –TM 01 mode converter is designed for a dual-mode operation over-moded relativistic backward-wave oscillator. With the converter, the fundamental mode output is achieved. Particle-in-cell simulation shows that the efficiency of beam-wave conversion was over 46% and a pureTM 01 mode output was obtained. Effects of end reflection provided by the mode converter were studied. Adequate TM 01 mode feedback provided by the converter enhances conversion efficiency. The distance between the mode converter and extraction cavity critically affect the generation of microwaves depending on the reflection phase of TM 01 mode feedback

  13. Online crowdsourcing for efficient rating of speech: a validation study.

    Science.gov (United States)

    McAllister Byun, Tara; Halpin, Peter F; Szeredi, Daniel

    2015-01-01

    Blinded listener ratings are essential for valid assessment of interventions for speech disorders, but collecting these ratings can be time-intensive and costly. This study evaluated the validity of speech ratings obtained through online crowdsourcing, a potentially more efficient approach. 100 words from children with /r/ misarticulation were electronically presented for binary rating by 35 phonetically trained listeners and 205 naïve listeners recruited through the Amazon Mechanical Turk (AMT) crowdsourcing platform. Bootstrapping was used to compare different-sized samples of AMT listeners against a "gold standard" (mode across all trained listeners) and an "industry standard" (mode across bootstrapped samples of three trained listeners). There was strong overall agreement between trained and AMT listeners. The "industry standard" level of performance was matched by bootstrapped samples with n = 9 AMT listeners. These results support the hypothesis that valid ratings of speech data can be obtained in an efficient manner through AMT. Researchers in communication disorders could benefit from increased awareness of this method. Readers will be able to (a) discuss advantages and disadvantages of data collection through the crowdsourcing platform Amazon Mechanical Turk (AMT), (b) describe the results of a validity study comparing samples of AMT listeners versus phonetically trained listeners in a speech-rating task. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Development and Validation of a Smartphone Heart Rate Acquisition Application for Health Promotion and Wellness Telehealth Applications

    OpenAIRE

    Gregoski, Mathew J.; Mueller, Martina; Vertegel, Alexey; Shaporev, Aleksey; Jackson, Brenda B.; Frenzel, Ronja M.; Sprehn, Sara M.; Treiber, Frank A.

    2012-01-01

    Objective. Current generation smartphones' video camera technologies enable photoplethysmographic (PPG) acquisition and heart rate (HR) measurement. The study objective was to develop an Android application and compare HRs derived from a Motorola Droid to electrocardiograph (ECG) and Nonin 9560BT pulse oximeter readings during various movement-free tasks. Materials and Methods. HRs were collected simultaneously from 14 subjects, ages 20 to 58, healthy or with clinical conditions, using the 3 ...

  15. Single-mode fiber laser based on core-cladding mode conversion.

    Science.gov (United States)

    Suzuki, Shigeru; Schülzgen, Axel; Peyghambarian, N

    2008-02-15

    A single-mode fiber laser based on an intracavity core-cladding mode conversion is demonstrated. The fiber laser consists of an Er-doped active fiber and two fiber Bragg gratings. One Bragg grating is a core-cladding mode converter, and the other Bragg grating is a narrowband high reflector that selects the lasing wavelength. Coupling a single core mode and a single cladding mode by the grating mode converter, the laser operates as a hybrid single-mode laser. This approach for designing a laser cavity provides a much larger mode area than conventional large-mode-area step-index fibers.

  16. Effect of modes interaction on the resistive wall mode stability

    International Nuclear Information System (INIS)

    Chen Longxi; Wu Bin

    2013-01-01

    Effects of modes interaction on the resistive wall mode (RWM) stability are studied. When considering the modes interaction effects, the linear growth rate of the most unstable (3, 1) mode decreases. After linear evolution, the RWM saturates at the nonlinear phase. The saturation can be attributed to flux piling up on the resistive wall. When some modes exist, the (3, 1) mode saturates at lower level compared with single mode evolution. Meanwhile, the magnetic energy of the (5, 2) mode increases correspondingly, but the magnetic energy saturation level of the (2, 1) mode changes weakly. (authors)

  17. Scaling Fiber Lasers to Large Mode Area: An Investigation of Passive Mode-Locking Using a Multi-Mode Fiber.

    Science.gov (United States)

    Ding, Edwin; Lefrancois, Simon; Kutz, Jose Nathan; Wise, Frank W

    2011-01-01

    The mode-locking of dissipative soliton fiber lasers using large mode area fiber supporting multiple transverse modes is studied experimentally and theoretically. The averaged mode-locking dynamics in a multi-mode fiber are studied using a distributed model. The co-propagation of multiple transverse modes is governed by a system of coupled Ginzburg-Landau equations. Simulations show that stable and robust mode-locked pulses can be produced. However, the mode-locking can be destabilized by excessive higher-order mode content. Experiments using large core step-index fiber, photonic crystal fiber, and chirally-coupled core fiber show that mode-locking can be significantly disturbed in the presence of higher-order modes, resulting in lower maximum single-pulse energies. In practice, spatial mode content must be carefully controlled to achieve full pulse energy scaling. This paper demonstrates that mode-locking performance is very sensitive to the presence of multiple waveguide modes when compared to systems such as amplifiers and continuous-wave lasers.

  18. Novel operation mode for eliminating influence of inclination angle and friction in atomic force microscopy

    International Nuclear Information System (INIS)

    Wang, Fei; Wang, Yueyu; Zhou, Faquan; Zhao, Xuezeng

    2010-01-01

    The accuracy of topography imaging in contact force mode of atomic force microscopy (AFM) depends on the one-to-one corresponding relationship between the cantilever deflection and the tip-sample distance, whereas such a relationship cannot be always achieved in the presence of friction and incline angle of sample surface. Recently, we have developed a novel operation mode in which we keep the van der Waals force as constant instead of the applied normal force, to eliminate the effect of inclination angle and friction on topography imaging in the contact force mode. We have improved our AFM to enable the new operation mode for validation. Comparative experiments have been performed and the results have shown that the effect of friction and inclination angle on topography imaging in contact mode of AFM can be eliminated or at least decreased effectively by working in the new operation mode we present.

  19. Acquisition Workforce Annual Report 2006

    Data.gov (United States)

    General Services Administration — This is the Federal Acquisition Institute's (FAI's) Annual demographic report on the Federal acquisition workforce, showing trends by occupational series, employment...

  20. Acquisition Workforce Annual Report 2008

    Data.gov (United States)

    General Services Administration — This is the Federal Acquisition Institute's (FAI's) Annual demographic report on the Federal acquisition workforce, showing trends by occupational series, employment...

  1. Predicting the ungauged basin: Model validation and realism assessment

    Directory of Open Access Journals (Sweden)

    Tim evan Emmerik

    2015-10-01

    Full Text Available The hydrological decade on Predictions in Ungauged Basins (PUB led to many new insights in model development, calibration strategies, data acquisition and uncertainty analysis. Due to a limited amount of published studies on genuinely ungauged basins, model validation and realism assessment of model outcome has not been discussed to a great extent. With this paper we aim to contribute to the discussion on how one can determine the value and validity of a hydrological model developed for an ungauged basin. As in many cases no local, or even regional, data are available, alternative methods should be applied. Using a PUB case study in a genuinely ungauged basin in southern Cambodia, we give several examples of how one can use different types of soft data to improve model design, calibrate and validate the model, and assess the realism of the model output. A rainfall-runoff model was coupled to an irrigation reservoir, allowing the use of additional and unconventional data. The model was mainly forced with remote sensing data, and local knowledge was used to constrain the parameters. Model realism assessment was done using data from surveys. This resulted in a successful reconstruction of the reservoir dynamics, and revealed the different hydrological characteristics of the two topographical classes. This paper does not present a generic approach that can be transferred to other ungauged catchments, but it aims to show how clever model design and alternative data acquisition can result in a valuable hydrological model for an ungauged catchment.

  2. Poster — Thur Eve — 30: 4D VMAT dose calculation methodology to investigate the interplay effect: experimental validation using TrueBeam Developer Mode and Gafchromic film

    Energy Technology Data Exchange (ETDEWEB)

    Teke, T; Milette, MP [BC Cancer Agency Centre for the Southern Interior (Canada); Huang, V; Thomas, SD [BC Cancer Agency Fraser Valley Cancer Centre (Canada)

    2014-08-15

    The interplay effect between the tumor motion and the radiation beam modulation during a VMAT treatment delivery alters the delivered dose distribution from the planned one. This work present and validate a method to accurately calculate the dose distribution in 4D taking into account the tumor motion, the field modulation and the treatment starting phase. A QUASAR™ respiratory motion phantom was 4D scanned with motion amplitude of 3 cm and with a 3 second period. A static scan was also acquired with the lung insert and the tumor contained in it centered. A VMAT plan with a 6XFFF beam was created on the averaged CT and delivered on a Varian TrueBeam and the trajectory log file was saved. From the trajectory log file 10 VMAT plans (one for each breathing phase) and a developer mode XML file were created. For the 10 VMAT plans, the tumor motion was modeled by moving the isocentre on the static scan, the plans were re-calculated and summed in the treatment planning system. In the developer mode, the tumor motion was simulated by moving the couch dynamically during the treatment. Gafchromic films were placed in the QUASAR phantom static and irradiated using the developer mode. Different treatment starting phase were investigated (no phase shift, maximum inhalation and maximum exhalation). Calculated and measured isodose lines and profiles are in very good agreement. For each starting phase, the dose distribution exhibit significant differences but are accurately calculated with the methodology presented in this work.

  3. Research on control law accelerator of digital signal process chip TMS320F28035 for real-time data acquisition and processing

    Science.gov (United States)

    Zhao, Shuangle; Zhang, Xueyi; Sun, Shengli; Wang, Xudong

    2017-08-01

    TI C2000 series digital signal process (DSP) chip has been widely used in electrical engineering, measurement and control, communications and other professional fields, DSP TMS320F28035 is one of the most representative of a kind. When using the DSP program, need data acquisition and data processing, and if the use of common mode C or assembly language programming, the program sequence, analogue-to-digital (AD) converter cannot be real-time acquisition, often missing a lot of data. The control low accelerator (CLA) processor can run in parallel with the main central processing unit (CPU), and the frequency is consistent with the main CPU, and has the function of floating point operations. Therefore, the CLA coprocessor is used in the program, and the CLA kernel is responsible for data processing. The main CPU is responsible for the AD conversion. The advantage of this method is to reduce the time of data processing and realize the real-time performance of data acquisition.

  4. Mode conversion of lower hybrid waves at high ion cyclotron harmonics. Appendix F

    International Nuclear Information System (INIS)

    Swanson, D.G.; Cho, S.

    1985-05-01

    The problem of ion cyclotron harmonic absorption for a lower hybrid wave is shown to be a mode conversion problem. A new form of the dispersion relation is developed and then expanded to get a differential equation identical to that for the second harmonic problem. The validity of this model is restricted to the region far from the lower hybrid resonance layer. It is shown that mode couplings occur among the incident cold wave and two other waves, and the tunneling factor becomes singular there

  5. Multi spectral scaling data acquisition system

    International Nuclear Information System (INIS)

    Behere, Anita; Patil, R.D.; Ghodgaonkar, M.D.; Gopalakrishnan, K.R.

    1997-01-01

    In nuclear spectroscopy applications, it is often desired to acquire data at high rate with high resolution. With the availability of low cost computers, it is possible to make a powerful data acquisition system with minimum hardware and software development, by designing a PC plug-in acquisition board. But in using the PC processor for data acquisition, the PC can not be used as a multitasking node. Keeping this in view, PC plug-in acquisition boards with on-board processor find tremendous applications. Transputer based data acquisition board has been designed which can be configured as a high count rate pulse height MCA or as a Multi Spectral Scaler. Multi Spectral Scaling (MSS) is a new technique, in which multiple spectra are acquired in small time frames and are then analyzed. This paper describes the details of this multi spectral scaling data acquisition system. 2 figs

  6. Acquisition Research Program Homepage

    OpenAIRE

    2015-01-01

    Includes an image of the main page on this date and compressed file containing additional web pages. Established in 2003, Naval Postgraduate School’s (NPS) Acquisition Research Program provides leadership in innovation, creative problem solving and an ongoing dialogue, contributing to the evolution of Department of Defense acquisition strategies.

  7. Improving quality of laser scanning data acquisition through calibrated amplitude and pulse deviation measurement

    Science.gov (United States)

    Pfennigbauer, Martin; Ullrich, Andreas

    2010-04-01

    Newest developments in laser scanner technologies put surveyors in the position to comply with the ever increasing demand of high-speed, high-accuracy, and highly reliable data acquisition from terrestrial, mobile, and airborne platforms. Echo digitization in pulsed time-of-flight laser ranging has demonstrated its superior performance in the field of bathymetry and airborne laser scanning for more than a decade, however at the cost of somewhat time consuming off line post processing. State-of-the-art online waveform processing as implemented in RIEGL's V-Line not only saves users post-processing time to obtain true 3D point clouds, it also adds the assets of calibrated amplitude and reflectance measurement for data classification and pulse deviation determination for effective and reliable data validation. We present results from data acquisitions in different complex target situations.

  8. Performance Confirmation Data Acquisition System

    International Nuclear Information System (INIS)

    D.W. Markman

    2000-01-01

    The purpose of this analysis is to identify and analyze concepts for the acquisition of data in support of the Performance Confirmation (PC) program at the potential subsurface nuclear waste repository at Yucca Mountain. The scope and primary objectives of this analysis are to: (1) Review the criteria for design as presented in the Performance Confirmation Data Acquisition/Monitoring System Description Document, by way of the Input Transmittal, Performance Confirmation Input Criteria (CRWMS M and O 1999c). (2) Identify and describe existing and potential new trends in data acquisition system software and hardware that would support the PC plan. The data acquisition software and hardware will support the field instruments and equipment that will be installed for the observation and perimeter drift borehole monitoring, and in-situ monitoring within the emplacement drifts. The exhaust air monitoring requirements will be supported by a data communication network interface with the ventilation monitoring system database. (3) Identify the concepts and features that a data acquisition system should have in order to support the PC process and its activities. (4) Based on PC monitoring needs and available technologies, further develop concepts of a potential data acquisition system network in support of the PC program and the Site Recommendation and License Application

  9. 48 CFR Appendix - Federal Acquisition Regulation (FAR) Index

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Federal Acquisition Regulation (FAR) Index Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT... (IFMS) Contract clause. FAR Index Federal Acquisition Regulation (FAR) Index Editorial Note: This...

  10. Reinventing the Platform Core Through Acquisition

    DEFF Research Database (Denmark)

    Toppenberg, Gustav; Henningsson, Stefan; Eaton, Ben

    2016-01-01

    the acquisition and integration of companies presenting innovative technologies of relevance to the platform core. Using a revelatory case study of Cisco Systems, we develop the explanatory notion of ‘coring acquisition’. In this type of acquisition value is created through the acquisition of companies...

  11. 10 CFR 626.4 - General acquisition strategy.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false General acquisition strategy. 626.4 Section 626.4 Energy DEPARTMENT OF ENERGY (CONTINUED) SALES REGULATION PROCEDURES FOR ACQUISITION OF PETROLEUM FOR THE STRATEGIC PETROLEUM RESERVE § 626.4 General acquisition strategy. (a) Criteria for commencing acquisition. To reduce...

  12. 48 CFR 1.102-3 - Acquisition team.

    Science.gov (United States)

    2010-10-01

    ... service. By identifying the team members in this manner, teamwork, unity of purpose, and open... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Acquisition team. 1.102-3... ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 1.102-3 Acquisition team. The purpose of defining...

  13. Wide-scope screening of pesticides in fruits and vegetables using information-dependent acquisition employing UHPLC-QTOF-MS and automated MS/MS library searching.

    Science.gov (United States)

    Wang, Zhibin; Cao, Yanzhong; Ge, Na; Liu, Xiaomao; Chang, Qiaoying; Fan, Chunlin; Pang, Guo-Fang

    2016-11-01

    This paper presents an application of ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) for simultaneous screening and identification of 427 pesticides in fresh fruit and vegetable samples. Both full MS scan mode for quantification, and an artificial-intelligence-based product ion scan mode information-dependent acquisition (IDA) providing automatic MS to MS/MS switching of product ion spectra for identification, were conducted by one injection. A home-in collision-induced-dissociation all product ions accurate mass spectra library containing more than 1700 spectra was developed prior to actual application. Both qualitative and quantitative validations of the method were carried out. The result showed that 97.4 % of the pesticides had the screening detection limit (SDL) less than 50 μg kg -1 and more than 86.7 % could be confirmed by accurate MS/MS spectra embodied in the home-made library. Meanwhile, calibration curves covering two orders of magnitude were performed, and they were linear over the concentration range studied for the selected matrices (from 5 to 500 μg kg -1 for most of the pesticides). Recoveries between 80 and 110 % in four matrices (apple, orange, tomato, and spinach) at two spiked levels, 10 and 100 μg kg -1 , was 88.7 or 86.8 %. Furthermore, the overall relative standard deviation (RSD, n = 12) for 94.3 % of the pesticides in 10 μg kg -1 and 98.1 % of the pesticides in 100 μg kg -1 spiked levels was less than 20 %. In order to validate the suitability for routine analysis, the method was applied to 448 fruit and vegetable samples purchased in different local markets. The results show 83.3 % of the analyzed samples have positive findings (higher than the limits of identification and quantification), and 412 commodity-pesticide combinations are identified in our scope. The approach proved to be a cost-effective, time-saving and powerful strategy for routine large

  14. Acquisition Pricing and Inventory Decisions on Dual-Source Spare-Part System with Final Production and Remanufacturing

    Directory of Open Access Journals (Sweden)

    Yancong Zhou

    2016-01-01

    Full Text Available The life spans of durable goods are longer than their warranty periods. To satisfy the service demand of spare parts and keep the market competition advantage, enterprises have to maintain the longer inventory planning of spare parts. However, how to obtain a valid number of spare parts is difficult for those enterprises. In this paper, we consider a spare-part inventory problem, where the inventory can be replenished by two ways including the final production order and the remanufacturing way. Especially for the remanufacturing way, we consider the acquisition management problem of used products concerning an acquisition pricing decision. In a multiperiod setting, we formulate the problem into a dynamic optimization problem, where the system decisions include the final production order and acquisition price of used products at each period. By stochastic dynamic programming, we obtain the optimal policy of the acquisition pricing at each period and give the optimal policy structure of the optimization problem at the first period. Then, a recursion algorithm is designed to calculate the optimal decisions and the critical points in the policy. Finally, the numerical analyses show the effects of demand information and customer’s sensitive degree on the related decisions and the optimal cost.

  15. WE-H-BRC-02: Failure Mode and Effect Analysis of Liver Stereotactic Body Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Rusu, I; Thomas, T; Roeske, J; Price, J; Perino, C; Surucu, M [Loyola University Chicago, Maywood, IL (United States); Mescioglu, I [Lewis University, Romeoville, IL (United States)

    2016-06-15

    Purpose: To identify areas of improvement in our liver stereotactic body radiation therapy (SBRT) program, using failure mode and effect analysis (FMEA). Methods: A multidisciplinary group consisting of one physician, three physicists, one dosimetrist and two therapists was formed. A process map covering 10 major stages of the liver SBRT program from the initial diagnosis to post treatment follow-up was generated. A total of 102 failure modes, together with their causes and effects, were identified. The occurrence (O), severity (S) and lack of detectability (D) were independently scored. The ranking was done using the risk probability number (RPN) defined as the product of average O, S and D numbers for each mode. The scores were normalized to remove inter-observer variability, while preserving individual ranking order. Further, a correlation analysis on the overall agreement on rank order of all failure modes resulted in positive values for successive pairs of evaluators. The failure modes with the highest RPN value were considered for further investigation. Results: The average normalized RPN values for all modes were 39 with a range of 9 to 103. The FMEA analysis resulted in the identification of the top 10 critical failures modes as: Incorrect CT-MR registration, MR scan not performed in treatment position, patient movement between CBCT acquisition and treatment, daily IGRT QA not verified, incorrect or incomplete ITV delineation, OAR contours not verified, inaccurate normal liver effective dose (Veff) calculation, failure of bolus tracking for 4D CT scan, setup instructions not followed for treatment and plan evaluation metrics missed. Conclusion: The application of FMEA to our liver SBRT program led to the identification and possible improvement of areas affecting patient safety.

  16. WE-H-BRC-02: Failure Mode and Effect Analysis of Liver Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Rusu, I; Thomas, T; Roeske, J; Price, J; Perino, C; Surucu, M; Mescioglu, I

    2016-01-01

    Purpose: To identify areas of improvement in our liver stereotactic body radiation therapy (SBRT) program, using failure mode and effect analysis (FMEA). Methods: A multidisciplinary group consisting of one physician, three physicists, one dosimetrist and two therapists was formed. A process map covering 10 major stages of the liver SBRT program from the initial diagnosis to post treatment follow-up was generated. A total of 102 failure modes, together with their causes and effects, were identified. The occurrence (O), severity (S) and lack of detectability (D) were independently scored. The ranking was done using the risk probability number (RPN) defined as the product of average O, S and D numbers for each mode. The scores were normalized to remove inter-observer variability, while preserving individual ranking order. Further, a correlation analysis on the overall agreement on rank order of all failure modes resulted in positive values for successive pairs of evaluators. The failure modes with the highest RPN value were considered for further investigation. Results: The average normalized RPN values for all modes were 39 with a range of 9 to 103. The FMEA analysis resulted in the identification of the top 10 critical failures modes as: Incorrect CT-MR registration, MR scan not performed in treatment position, patient movement between CBCT acquisition and treatment, daily IGRT QA not verified, incorrect or incomplete ITV delineation, OAR contours not verified, inaccurate normal liver effective dose (Veff) calculation, failure of bolus tracking for 4D CT scan, setup instructions not followed for treatment and plan evaluation metrics missed. Conclusion: The application of FMEA to our liver SBRT program led to the identification and possible improvement of areas affecting patient safety.

  17. Cross-mode bioelectrical impedance analysis in a standing position for estimating fat-free mass validated against dual-energy x-ray absorptiometry.

    Science.gov (United States)

    Huang, Ai-Chun; Chen, Yu-Yawn; Chuang, Chih-Lin; Chiang, Li-Ming; Lu, Hsueh-Kuan; Lin, Hung-Chi; Chen, Kuen-Tsann; Hsiao, An-Chi; Hsieh, Kuen-Chang

    2015-11-01

    Bioelectrical impedance analysis (BIA) is commonly used to assess body composition. Cross-mode (left hand to right foot, Z(CR)) BIA presumably uses the longest current path in the human body, which may generate better results when estimating fat-free mass (FFM). We compared the cross-mode with the hand-to-foot mode (right hand to right foot, Z(HF)) using dual-energy x-ray absorptiometry (DXA) as the reference. We hypothesized that when comparing anthropometric parameters using stepwise regression analysis, the impedance value from the cross-mode analysis would have better prediction accuracy than that from the hand-to-foot mode analysis. We studied 264 men and 232 women (mean ages, 32.19 ± 14.95 and 34.51 ± 14.96 years, respectively; mean body mass indexes, 24.54 ± 3.74 and 23.44 ± 4.61 kg/m2, respectively). The DXA-measured FFMs in men and women were 58.85 ± 8.15 and 40.48 ± 5.64 kg, respectively. Multiple stepwise linear regression analyses were performed to construct sex-specific FFM equations. The correlations of FFM measured by DXA vs. FFM from hand-to-foot mode and estimated FFM by cross-mode were 0.85 and 0.86 in women, with standard errors of estimate of 2.96 and 2.92 kg, respectively. In men, they were 0.91 and 0.91, with standard errors of the estimates of 3.34 and 3.48 kg, respectively. Bland-Altman plots showed limits of agreement of -6.78 to 6.78 kg for FFM from hand-to-foot mode and -7.06 to 7.06 kg for estimated FFM by cross-mode for men, and -5.91 to 5.91 and -5.84 to 5.84 kg, respectively, for women. Paired t tests showed no significant differences between the 2 modes (P > .05). Hence, cross-mode BIA appears to represent a reasonable and practical application for assessing FFM in Chinese populations. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Data Acquisition for Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor); Grodsinsky, Carlos M. (Inventor)

    2014-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to collect data asynchronously, via the bus, from the memory of the plurality of data acquisition modules according to a relative fullness of the memory of the plurality of data acquisition modules.

  19. Microprocessor event analysis in parallel with Camac data acquisition

    International Nuclear Information System (INIS)

    Cords, D.; Eichler, R.; Riege, H.

    1981-01-01

    The Plessey MIPROC-16 microprocessor (16 bits, 250 ns execution time) has been connected to a Camac System (GEC-ELLIOTT System Crate) and shares the Camac access with a Nord-1OS computer. Interfaces have been designed and tested for execution of Camac cycles, communication with the Nord-1OS computer and DMA-transfer from Camac to the MIPROC-16 memory. The system is used in the JADE data-acquisition-system at PETRA where it receives the data from the detector in parallel with the Nord-1OS computer via DMA through the indirect-data-channel mode. The microprocessor performs an on-line analysis of events and the result of various checks is appended to the event. In case of spurious triggers or clear beam gas events, the Nord-1OS buffer will be reset and the event omitted from further processing. (orig.)

  20. Commissioning of the control and data acquisition electronics for the CDF Silicon Vertex Detector

    International Nuclear Information System (INIS)

    Tkaczyk, S.M.; Turner, K.J.; Nelson, C.A.; Shaw, T.M.; Wesson, T.R.; Bailey, M.W.; Kruse, M.C.; Castro, A.

    1991-11-01

    The SVX data acquisition system includes three components: a Fastbus Sequencer, an SVX Rabbit Crate Controller and a Digitizer. These modules are integrated into the CDF DAQ system and operate the readout chips. The results of the extensive functional tests of the SVX modules are reported. We discuss the stability of the Sequencers, systematic differences between them and methods of synchronization with the Tevatron beam crossings. The Digitizer ADC calibration procedure run on the microsequencer is described. The microsequencer code used for data taking and SVX chip calibration modes is described. Measurements of the SVX data scan time are discussed

  1. New KENS data acquisition system

    International Nuclear Information System (INIS)

    Arai, M.; Furusaka, M.; Satoh, S.

    1989-01-01

    In this report, the authors discuss a data acquisition system, KENSnet, which is newly introduced to the KENS facility. The criteria for the data acquisition system was about 1 MIPS for CPU speed and 150 Mbytes for storage capacity for a computer per spectrometer. VAX computers were chosen with their propreitary operating system, VMS. The Vax computers are connected by a DECnet network mediated by Ethernet. Front-end computers, Apple Macintosh Plus and Macintosh II, were chosen for their user-friendly manipulation and intelligence. New CAMAC-based data acquisition electronics were developed. The data acquisition control program (ICP) and the general data analysis program (Genie) were both developed at ISIS and have been installed. 2 refs., 3 figs., 1 tab

  2. Studies in Filipino Second Language Acquisition.

    Science.gov (United States)

    Ramos, Teresita V.

    Very little research has been done on first or second language acquisition in the Philippines. Most second language learning studies cited in the literature concern acquisition of English in English-speaking communities, and most American studies of Filipino language acquisition are superficial, consisting primarily of morpheme analysis. The…

  3. Collection assessment and acquisitions budgets

    CERN Document Server

    Lee, Sul H

    2013-01-01

    This invaluable new book contains timely information about the assessment of academic library collections and the relationship of collection assessment to acquisition budgets. The rising cost of information significantly influences academic libraries'abilities to acquire the necessary materials for students and faculty, and public libraries'abilities to acquire material for their clientele. Collection Assessment and Acquisitions Budgets examines different aspects of the relationship between the assessment of academic library collections and the management of library acquisition budgets. Librar

  4. [Validity of axis III "Conflicts" of Operationalized Psychodynamic Diagnostics (OPD-1)--empirical results and conclusions for OPD-2].

    Science.gov (United States)

    Schneider, Gudrun; Mendler, Till; Heuft, Gereon; Burgmer, Markus

    2008-01-01

    Using specific psychometric instruments, we investigate criteria-related validity of axis III ("conflicts") of OPD-1 by a priori formulated hypotheses concerning the relations to the main conflict/mode. A consecutive sample of 105 psychotherapy inpatients was examined using self-assessment scales (Inventory of Interpersonal Problems; Rosenberg Self-Esteem Scale, Test of Self-Conscious Affect; Toronto Alexithymia-Scale; Frankfurt Self Concept Scales) and videotaped OPD research interviews in the first week after admission to the hospital. Two OPD-certified raters first rated the interviews independently, then in a consensus rating. Due to the different frequency of the main conflict and mode, evaluation of 4 of 7 conflicts was possible. The a priori hypotheses could be confirmed for the conflicts Dependence versus Autonomy (both modes), Submission versus Control (active mode), Desire for Care versus Autarchy (active mode), and Self-Value (passive mode). Confirmation of the a priori hypotheses indicates validity of axis III (Conflicts) of OPD. We discuss the small numbers of some conflicts, the comparison of expert rating OPD with self-assessment and the meaning of the results for OPD-2.

  5. Mode Selection in Flame-Vortex driven Combustion Instabilities

    KAUST Repository

    Speth, Ray

    2011-01-04

    In this paper, we investigate flame-vortex interaction in a lean premixed, laboratory scale, backward-facing step combustor. Two series of tests were conducted, using propane/hydrogen mixtures and carbon monoxide/hydrogen mixtures as fuels, respectively. Pressure measurements and high speed particle imaging velocimetry (PIV) were employed to generate pressure response curves as well as the images of the velocity field and the flame brush. We demonstrate that the step combustor exhibits several operating modes depending on the inlet conditions and fuel composition, characterized by the amplitude and frequency of pressure oscillations along with distinct dynamic flame shapes. We propose a model in which the combustor\\'s selection of the acoustic mode is governed by a combustion-related time delay inversely proportional to the flame speed. Our model predicts the transition between distinct operating modes. We introduce non-dimensional parameters characterizing the flame speed and stretch rate, and develop a relationship between these quantities at the operating conditions corresponding to each mode transition. Based on this relationship, we show that numerically-calculated density-weighted strained flame speed can be used to collapse the combustion dynamics data over the full range of conditions (inlet temperature, fuel composition, and equivalence ratio). Finally, we validate our strain flame based model by measuring the strain rate using the flame image and the velocity field from the PIV measurement. Our results show that the measured strain rates lie in the same range as the critical values at the transitions among distinct modes as those predicted by our model.

  6. ``Green's function'' approach & low-mode asymmetries

    Science.gov (United States)

    Masse, Laurent; Clark, Dan; Salmonson, Jay; MacLaren, Steve; Ma, Tammy; Khan, Shahab; Pino, Jesse; Ralph, Jo; Czajka, C.; Tipton, Robert; Landen, Otto; Kyrala, Georges; 2 Team; 1 Team

    2017-10-01

    Long wavelength, low mode asymmetries are believed to play a leading role in limiting the performance of current ICF implosions on NIF. These long wavelength modes are initiated and driven by asymmetries in the x-ray flux from the hohlraum; however, the underlying hydrodynamics of the implosion also act to amplify these asymmetries. The work presented here aim to deepen our understanding of the interplay of the drive asymmetries and the underlying implosion hydrodynamics in determining the final imploded configuration. This is accomplished through a synthesis of numerical modeling, analytic theory, and experimental data. In detail, we use a Green's function approach to connect the drive asymmetry seen by the capsule to the measured inflight and hot spot symmetries. The approach has been validated against a suite of numerical simulations. Ultimately, we hope this work will identify additional measurements to further constrain the asymmetries and increase hohlraum illumination design flexibility on the NIF. The technique and derivation of associated error bars will be presented. LLC, (LLNS) Contract No. DE-AC52-07NA27344.

  7. Analysis of Statoliths Displacement in Chara Rhizoids for Validating the Microgravity-Simulation Quality of Clinorotation Modes

    Science.gov (United States)

    Krause, Lars; Braun, Markus; Hauslage, Jens; Hemmersbach, Ruth

    2018-05-01

    In single-celled rhizoids of the green algae Chara, positively gravitropic growth is governed by statoliths kept in a dynamically stable position 10-25 μ m above the cell tip by a complex interaction of gravity and actomyosin forces. Any deviation of the tube-like cells from the tip-downward orientation causes statoliths to sediment onto the gravisensitive subapical cell flank which initiates a gravitropic curvature response. Microgravity experiments have shown that abolishing the net tip-directed gravity force results in an actomyosin-mediated axial displacement of statoliths away from the cell tip. The present study was performed to critically assess the quality of microgravity simulation provided by different operational modes of a Random Positioning Machine (RPM) running with one axis (2D mode) or two axes (3D mode) and different rotational speeds (2D), speed ranges and directions (3D). The effects of 2D and 3D rotation were compared with data from experiments in real microgravity conditions (MAXUS sounding rocket missions). Rotational speeds in the range of 60-85 rpm in 2D and 3D modes resulted in a similar kinetics of statolith displacement as compared to real microgravity data, while slower clinorotation (2-11 rpm) caused a reduced axial displacement and a more dispersed arrangement of statoliths closer to the cell tip. Increasing the complexity of rotation by adding a second rotation axis in case of 3D clinorotation did not increase the quality of microgravity simulation, however, increased side effects such as the level of vibrations resulting in a more dispersed arrangement of statoliths. In conclusion, fast 2D clinorotation provides the most appropriate microgravity simulation for investigating the graviperception mechanism in Chara rhizoids, whereas slower clinorotation speeds and rotating samples around two axes do not improve the quality of microgravity simulation.

  8. Large-scale multimodal transport modelling. Part 2: Implementation and validation

    CSIR Research Space (South Africa)

    Van Heerden, Q

    2013-07-01

    Full Text Available their individual utilities using both time and cost elements. The agent-based model is run for the Nelson Mandela Bay Metropolitan area using multiple modes that include commercial vehicles. We validate the simulation results against regional traffic counts...

  9. Risk analysis by FMEA as an element of analytical validation.

    Science.gov (United States)

    van Leeuwen, J F; Nauta, M J; de Kaste, D; Odekerken-Rombouts, Y M C F; Oldenhof, M T; Vredenbregt, M J; Barends, D M

    2009-12-05

    We subjected a Near-Infrared (NIR) analytical procedure used for screening drugs on authenticity to a Failure Mode and Effects Analysis (FMEA), including technical risks as well as risks related to human failure. An FMEA team broke down the NIR analytical method into process steps and identified possible failure modes for each step. Each failure mode was ranked on estimated frequency of occurrence (O), probability that the failure would remain undetected later in the process (D) and severity (S), each on a scale of 1-10. Human errors turned out to be the most common cause of failure modes. Failure risks were calculated by Risk Priority Numbers (RPNs)=O x D x S. Failure modes with the highest RPN scores were subjected to corrective actions and the FMEA was repeated, showing reductions in RPN scores and resulting in improvement indices up to 5.0. We recommend risk analysis as an addition to the usual analytical validation, as the FMEA enabled us to detect previously unidentified risks.

  10. Determining the mode of high voltage breakdowns in vacuum devices

    International Nuclear Information System (INIS)

    Miller, H.C.; Furno, E.J.; Sturtz, J.P.

    1980-01-01

    High voltage breakdowns (HVBs) occur in many vacuum devices. It frequently is of great practical interest to know the type (or mode) of such HVB's, since this can indicate weak points in the device. Post-mortems can sometimes be helpful, but it would be quite desirable to have a technique which would allow the HVB mode to be determined in an operating device. Photography can be quite helpful, but unfortunately many devices do not permit optical access to the region of interest. However, the idea of using photography in conjunction with other diagnostic techniques to establish the validity of these techniques seemed promising, since these techniques could then be used to determine the mode of HVBs in opaque devices. A literature search indicates that promising techniques are to measure the voltage applied to the device (or the current through the device) and also to look for x-rays generated by the device during an HVB

  11. Eliminating the zero spectrum in Fourier transform profilometry using empirical mode decomposition.

    Science.gov (United States)

    Li, Sikun; Su, Xianyu; Chen, Wenjing; Xiang, Liqun

    2009-05-01

    Empirical mode decomposition is introduced into Fourier transform profilometry to extract the zero spectrum included in the deformed fringe pattern without the need for capturing two fringe patterns with pi phase difference. The fringe pattern is subsequently demodulated using a standard Fourier transform profilometry algorithm. With this method, the deformed fringe pattern is adaptively decomposed into a finite number of intrinsic mode functions that vary from high frequency to low frequency by means of an algorithm referred to as a sifting process. Then the zero spectrum is separated from the high-frequency components effectively. Experiments validate the feasibility of this method.

  12. HIFU Monitoring and Control with Dual-Mode Ultrasound Arrays

    Science.gov (United States)

    Casper, Andrew Jacob

    The biological effects of high-intensity focused ultrasound (HIFU) have been known and studied for decades. HIFU has been shown capable of treating a wide variety of diseases and disorders. However, despite its demonstrated potential, HIFU has been slow to gain clinical acceptance. This is due, in part, to the difficulty associated with robustly monitoring and controlling the delivery of the HIFU energy. The non-invasive nature of the surgery makes the assessment of treatment progression difficult, leading to long treatment times and a significant risk of under treatment. This thesis research develops new techniques and systems for robustly monitoring HIFU therapies for the safe and efficacious delivery of the intended treatment. Systems and algorithms were developed for the two most common modes of HIFU delivery systems: single-element and phased array applicators. Delivering HIFU with a single element transducer is a widely used technique in HIFU therapies. The simplicity of a single element offers many benefits in terms of cost and overall system complexity. Typical monitoring schemes rely on an external device (e.g. diagnostic ultrasound or MRI) to assess the progression of therapy. The research presented in this thesis explores using the same element to both deliver and monitor the HIFU therapy. The use of a dual-mode ultrasound transducer (DMUT) required the development of an FPGA based single-channel arbitrary waveform generator and high-speed data acquisition unit. Data collected from initial uncontrolled ablations led to the development of monitoring and control algorithms which were implemented directly on the FPGA. Close integration between the data acquisition and arbitrary waveform units allowed for fast, low latency control over the ablation process. Results are presented that demonstrate control of HIFU therapies over a broad range of intensities and in multiple in vitro tissues. The second area of investigation expands the DMUT research to an

  13. Results from a Test Fixture for button BPM Trapped Mode Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cameron,P.; Bacha, B.; Blednykh, A.; Pinayev, I.; Singh, O.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1) Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.

  14. Research of aerial imaging spectrometer data acquisition technology based on USB 3.0

    Science.gov (United States)

    Huang, Junze; Wang, Yueming; He, Daogang; Yu, Yanan

    2016-11-01

    With the emergence of UAV (unmanned aerial vehicle) platform for aerial imaging spectrometer, research of aerial imaging spectrometer DAS(data acquisition system) faces new challenges. Due to the limitation of platform and other factors, the aerial imaging spectrometer DAS requires small-light, low-cost and universal. Traditional aerial imaging spectrometer DAS system is expensive, bulky, non-universal and unsupported plug-and-play based on PCIe. So that has been unable to meet promotion and application of the aerial imaging spectrometer. In order to solve these problems, the new data acquisition scheme bases on USB3.0 interface.USB3.0 can provide guarantee of small-light, low-cost and universal relying on the forward-looking technology advantage. USB3.0 transmission theory is up to 5Gbps.And the GPIF programming interface achieves 3.2Gbps of the effective theoretical data bandwidth.USB3.0 can fully meet the needs of the aerial imaging spectrometer data transmission rate. The scheme uses the slave FIFO asynchronous data transmission mode between FPGA and USB3014 interface chip. Firstly system collects spectral data from TLK2711 of high-speed serial interface chip. Then FPGA receives data in DDR2 cache after ping-pong data processing. Finally USB3014 interface chip transmits data via automatic-dma approach and uploads to PC by USB3.0 cable. During the manufacture of aerial imaging spectrometer, the DAS can achieve image acquisition, transmission, storage and display. All functions can provide the necessary test detection for aerial imaging spectrometer. The test shows that system performs stable and no data lose. Average transmission speed and storage speed of writing SSD can stabilize at 1.28Gbps. Consequently ,this data acquisition system can meet application requirements for aerial imaging spectrometer.

  15. Quantitation of respiratory motion during 4D-PET/CT acquisition

    International Nuclear Information System (INIS)

    Nehmeh, S.A.; Erdi, Y.E.; Pan, T.; Yorke, E.; Mageras, G.S.; Rosenzweig, K.E.; Schoder, H.; Mostafavi, H.; Squire, O.; Pevsner, A.; Larson, S.M.; Humm, J.L.

    2004-01-01

    We report on the variability of the respiratory motion during 4D-PET/CT acquisition. The respiratory motion for five lung cancer patients was monitored by tracking external markers placed on the abdomen. CT data were acquired over an entire respiratory cycle at each couch position. The x-ray tube status was recorded by the tracking system, for retrospective sorting of the CT data as a function of respiration phase. Each respiratory cycle was sampled in ten equal bins. 4D-PET data were acquired in gated mode, where each breathing cycle was divided into ten 500 ms bins. For both CT and PET acquisition, patients received audio prompting to regularize breathing. The 4D-CT and 4D-PET data were then correlated according to their respiratory phases. The respiratory periods, and average amplitude within each phase bin, acquired in both modality sessions were then analyzed. The average respiratory motion period during 4D-CT was within 18% from that in the 4D-PET sessions. This would reflect up to 1.8% fluctuation in the duration of each 4D-CT bin. This small uncertainty enabled good correlation between CT and PET data, on a phase-to-phase basis. Comparison of the average-amplitude within the respiration trace, between 4D-CT and 4D- PET, on a bin-by-bin basis show a maximum deviation of ∼15%. This study has proved the feasibility of performing 4D-PET/CT acquisition. Respiratory motion was in most cases consistent between PET and CT sessions, thereby improving both the attenuation correction of PET images, and co-registration of PET and CT images. On the other hand, in two patients, there was an increased partial irregularity in their breathing motion, which would prevent accurately correlating the corresponding PET and CT images

  16. Microcomputer data acquisition and control.

    Science.gov (United States)

    East, T D

    1986-01-01

    In medicine and biology there are many tasks that involve routine well defined procedures. These tasks are ideal candidates for computerized data acquisition and control. As the performance of microcomputers rapidly increases and cost continues to go down the temptation to automate the laboratory becomes great. To the novice computer user the choices of hardware and software are overwhelming and sadly most of the computer sales persons are not at all familiar with real-time applications. If you want to bill your patients you have hundreds of packaged systems to choose from; however, if you want to do real-time data acquisition the choices are very limited and confusing. The purpose of this chapter is to provide the novice computer user with the basics needed to set up a real-time data acquisition system with the common microcomputers. This chapter will cover the following issues necessary to establish a real time data acquisition and control system: Analysis of the research problem: Definition of the problem; Description of data and sampling requirements; Cost/benefit analysis. Choice of Microcomputer hardware and software: Choice of microprocessor and bus structure; Choice of operating system; Choice of layered software. Digital Data Acquisition: Parallel Data Transmission; Serial Data Transmission; Hardware and software available. Analog Data Acquisition: Description of amplitude and frequency characteristics of the input signals; Sampling theorem; Specification of the analog to digital converter; Hardware and software available; Interface to the microcomputer. Microcomputer Control: Analog output; Digital output; Closed-Loop Control. Microcomputer data acquisition and control in the 21st Century--What is in the future? High speed digital medical equipment networks; Medical decision making and artificial intelligence.

  17. 40 Gbps data acquisition system for NectarCAM

    Science.gov (United States)

    Hoffmann, Dirk; Houles, Julien; NectarCAM Team; CTA Consortium, the

    2017-10-01

    The Cherenkov Telescope Array (CTA) will be the next generation ground-based gamma-ray observatory. It will be made up of approximately 100 telescopes of three different sizes, from 4 to 23 meters in diameter. The previously presented prototype of a high speed data acquisition (DAQ) system for CTA (CHEP 2012, [6]) has become concrete within the NectarCAM project, one of the most challenging camera projects with very demanding needs for bandwidth of data handling. We designed a Linux-PC system able to concentrate and process without packet loss the 40 Gb/s average data rate coming from the 265 Front End Boards (FEB) through Gigabit Ethernet links, and to reduce data to fit the two ten-Gigabit Ethernet downstream links by external trigger decisions as well as custom tailored compression algorithms. Within the given constraints, we implemented de-randomisation of the event fragments received as relatively small UDP packets emitted by the FEB, using off-the-shelf equipment as required by the project and for an operation period of at least 30 years. We tested out-of-the-box interfaces and used original techniques to cope with these requirements, and set up a test bench with hundreds of synchronous Gigabit links in order to validate and tune the acquisition chain including downstream data logging based on zeroMQ and Google ProtocolBuffers [8].

  18. Knowledge-sharing Behavior and Post-acquisition Integration Failure

    DEFF Research Database (Denmark)

    Gammelgaard, Jens; Husted, Kenneth; Michailova, Snejina

    2004-01-01

    AbstractNot achieving the anticipated synergy effects in the post-acquisition integration context is a serious causefor the high acquisition failure rate. While existing studies on failures of acquisitions exist fromeconomics, finance, strategy, organization theory, and human resources management......, this paper appliesinsights from the knowledge-sharing literature. The paper establishes a conceptual link between obstaclesin the post-acquisition integration processes and individual knowledge-sharing behavior as related toknowledge transmitters and knowledge receivers. We argue that such an angle offers...... important insights toexplaining the high failure rate in acquisitions.Descriptors: post-acquisition integration, acquisition failure, individual knowledge-sharing behavior...

  19. Merging Platform Ecosystems in Technology Acquisitions

    DEFF Research Database (Denmark)

    Dowie, Jamie; Henningsson, Stefan; Kude, Thomas

    2017-01-01

    of the merging companies. Given the increasing importance of platforms and value co-creation with third-party providers for companies making technology acquisitions, we complement existing literature by reframing the analysis of technology acquisitions to include the merger of the broader partner ecosystems....... Specifically, we draw on theories of ecosystem governance to analyze how ecosystem tensions unfolded during the ecosystem merger and how the acquirer governed these tensions in SAP SE’s acquisition of the e-commerce provider Hybris AG. Our findings suggest that the governance of ecosystem tensions...... is an important aspect of managing technology acquisitions. We identify the pre-acquisition relation between the acquired company’s ecosystem partners and the acquirer as an important context factor for explaining how a partner company is exposed to the ecosystem tensions during the merger....

  20. IT Consultants in Acquisition IT Integration

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Øhrgaard, Christian

    2016-01-01

    strategic IT initiatives and how companies can draw effectively on their services. The paper investigates the use of consultants in relation to one type of major strategic IT initiative: acquisition IT integration. Acquisition IT integration, which is the integration of the acquirer’s and target......’s IT following a corporate acquisition, presents a difficult but crucial IT challenge for the many acquiring organizations. Through a comparative case study of four acquirers, theoretically grounded in the resource-based view of the firm, it is analyzed how acquirers draw on external consultants to realize...... acquisition IT integration. Two complementary and two supplementary roles consultants assume in these projects are identified. Additionally, three characteristics of the acquisition IT integration strategy are identified that influence how the acquirers assign different roles to IT consultants. The resulting...

  1. Customized shaping of vibration modes by acoustic metamaterial synthesis

    Science.gov (United States)

    Xu, Jiawen; Li, Shilong; Tang, J.

    2018-04-01

    Acoustic metamaterials have attractive potential in elastic wave guiding and attenuation over specific frequency ranges. The vast majority of related investigations are on transient waves. In this research we focus on stationary wave manipulation, i.e., shaping of vibration modes. Periodically arranged piezoelectric transducers shunted with inductive circuits are integrated to a beam structure to form a finite-length metamaterial beam. We demonstrate for the first time that, under a given operating frequency of interest, we can facilitate a metamaterial design such that this frequency becomes a natural frequency of the integrated system. Moreover, the vibration mode corresponding to this natural frequency can be customized and shaped to realize tailored/localized response distribution. This is fundamentally different from previous practices of utilizing geometry modification and/or feedback control to achieve mode tailoring. The metamaterial design is built upon the combinatorial effects of the bandgap feature and the effective resonant cavity feature, both attributed to the dynamic characteristics of the metamaterial beam. Analytical investigations based on unit-cell dynamics and modal analysis of the metamaterial beam are presented to reveal the underlying mechanism. Case illustrations are validated by finite element analyses. Owing to the online tunability of circuitry integrated, the proposed mode shaping technique can be online adjusted to fit specific requirements. The customized shaping of vibration modes by acoustic metamaterial synthesis has potential applications in vibration suppression, sensing enhancement and energy harvesting.

  2. Validity of Wearable Activity Monitors during Cycling and Resistance Exercise.

    Science.gov (United States)

    Boudreaux, Benjamin D; Hebert, Edward P; Hollander, Daniel B; Williams, Brian M; Cormier, Corinne L; Naquin, Mildred R; Gillan, Wynn W; Gusew, Emily E; Kraemer, Robert R

    2018-03-01

    The use of wearable activity monitors has seen rapid growth; however, the mode and intensity of exercise could affect the validity of heart rate (HR) and caloric (energy) expenditure (EE) readings. There is a lack of data regarding the validity of wearable activity monitors during graded cycling regimen and a standard resistance exercise. The present study determined the validity of eight monitors for HR compared with an ECG and seven monitors for EE compared with a metabolic analyzer during graded cycling and resistance exercise. Fifty subjects (28 women, 22 men) completed separate trials of graded cycling and three sets of four resistance exercises at a 10-repetition-maximum load. Monitors included the following: Apple Watch Series 2, Fitbit Blaze, Fitbit Charge 2, Polar H7, Polar A360, Garmin Vivosmart HR, TomTom Touch, and Bose SoundSport Pulse (BSP) headphones. HR was recorded after each cycling intensity and after each resistance exercise set. EE was recorded after both protocols. Validity was established as having a mean absolute percent error (MAPE) value of ≤10%. The Polar H7 and BSP were valid during both exercise modes (cycling: MAPE = 6.87%, R = 0.79; resistance exercise: MAPE = 6.31%, R = 0.83). During cycling, the Apple Watch Series 2 revealed the greatest HR validity (MAPE = 4.14%, R = 0.80). The BSP revealed the greatest HR accuracy during resistance exercise (MAPE = 6.24%, R = 0.86). Across all devices, as exercise intensity increased, there was greater underestimation of HR. No device was valid for EE during cycling or resistance exercise. HR from wearable devices differed at different exercise intensities; EE estimates from wearable devices were inaccurate. Wearable devices are not medical devices, and users should be cautious when using these devices for monitoring physiological responses to exercise.

  3. Operational experience with the CMS Data Acquisition System

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The data-acquisition (DAQ) system of the CMS experiment at the LHC performs the read-out and assembly of events accepted by the first level hardware trigger. Assembled events are made available to the high-level trigger (HLT), which selects interesting events for offline storage and analysis. The system is designed to handle a maximum input rate of 100 kHz and an aggregated throughput of 100 GB/s originating from approximately 500 sources and 10^8 electronic channels. An overview of the architecture and design of the hardware and software of the DAQ system is given. We report on the performance and operational experience of the DAQ and its Run Control System in the first two years of collider run of the LHC, both in proton-proton and Pb-Pb collisions. We present an analysis of the current performance, its limitations, and the most common failure modes and discuss the ongoing evolution of the HLT capability needed to match the luminosity ramp-up of the LHC.

  4. Guided exploration of physically valid shapes for furniture design

    KAUST Repository

    Umetani, Nobuyuki

    2012-07-01

    Geometric modeling and the physical validity of shapes are traditionally considered independently. This makes creating aesthetically pleasing yet physically valid models challenging. We propose an interactive design framework for efficient and intuitive exploration of geometrically and physically valid shapes. During any geometric editing operation, the proposed system continuously visualizes the valid range of the parameter being edited. When one or more constraints are violated after an operation, the system generates multiple suggestions involving both discrete and continuous changes to restore validity. Each suggestion also comes with an editing mode that simultaneously adjusts multiple parameters in a coordinated way to maintain validity. Thus, while the user focuses on the aesthetic aspects of the design, our computational design framework helps to achieve physical realizability by providing active guidance to the user. We demonstrate our framework on plankbased furniture design with nail-joint and frictional constraints. We use our system to design a range of examples, conduct a user study, and also fabricate a physical prototype to test the validity and usefulness of the system. © 2012 ACM 0730-0301/2012/08- ART86.

  5. Adaptive Sliding Mode Control of Chaos in Permanent Magnet Synchronous Motor via Fuzzy Neural Networks

    Directory of Open Access Journals (Sweden)

    Tat-Bao-Thien Nguyen

    2014-01-01

    Full Text Available In this paper, based on fuzzy neural networks, we develop an adaptive sliding mode controller for chaos suppression and tracking control in a chaotic permanent magnet synchronous motor (PMSM drive system. The proposed controller consists of two parts. The first is an adaptive sliding mode controller which employs a fuzzy neural network to estimate the unknown nonlinear models for constructing the sliding mode controller. The second is a compensational controller which adaptively compensates estimation errors. For stability analysis, the Lyapunov synthesis approach is used to ensure the stability of controlled systems. Finally, simulation results are provided to verify the validity and superiority of the proposed method.

  6. Modeling the factors that influence knowledge transfer in mergers and acquisitions

    Institute of Scientific and Technical Information of China (English)

    YU Haiyan; LIANG Zhanping

    2010-01-01

    This paper constructs a model on the factors that influence knowledge transfer in mergers and acquisitions (M&A) and validates it via questionnaire surveys.Using 125 valid collected questionnaires,multiple linear regression analysis and hierarchical regression analysis showed that five out of the ten factors had a positive effect on knowledge transfer effect.The ranking of factor importance,from high to low,was knowledge explicitness,relationship quality,learning intent,advanced transfer activities,and learning capability,which is fairly consistent with positive factors observed in other interorganizational knowledge transfer researches.Our results also showed that one of the control variables (size of acquired firm) had neither a direct or indirect effect on knowledge transfer in M&A.Additionally,our research found that knowledge distance and degree of M&A integration had a positive influence on knowledge transfer effect at the early stage after M&A,but had a negative influence at the late stage.Based on this research,several suggestions for knowledge transfer in M&A are proposed.

  7. Modeling the factors that influence knowledge transfer in mergers and acquisitions

    Institute of Scientific and Technical Information of China (English)

    YU; Haiyan; LIANG; Zhanping

    2010-01-01

    This paper constructs a model on the factors that influence knowledge transfer in mergers and acquisitions(M&A)and validates it via questionnaire surveys.Using 125valid collected questionnaires,multiple linear regression analysis and hierarchical regression analysis showed that five out of the ten factors had a positive effect on knowledge transfer effect.The ranking of factor importance,from high to low,was knowledge explicitness,relationship quality,learning intent,advanced transfer activities,and learning capability,which is fairly consistent with positive factors observed in other interorganizational knowledge transfer researches.Our results also showed that one of the control variables(size of acquired firm)had neither a direct or indirect effect on knowledge transfer in M&A.Additionally,our research found that knowledge distance and degree of M&A integration had a positive influence on knowledge transfer effect at the early stage after M&A,but had a negative influence at the late stage.Based on this research,several suggestions for knowledge transfer in M&A are proposed.

  8. Managing IT Integration Risk in Acquisitions

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Kettinger, William J.

    2016-01-01

    The article discusses a framework for evaluating risk of information technology (IT) integration in acquisitions. Topics include the use of the experience of serial acquirer Trelleborg AB to show the merits of the framework for managing the risk and to determine low-risk acquisitions......, the importance of managing IT integration risk, and various risk areas for acquisition IT integration....

  9. Unmanned Maritime Systems Incremental Acquisition Approach

    Science.gov (United States)

    2016-12-01

    REPORT TYPE AND DATES COVERED MBA professional report 4. TITLE AND SUBTITLE UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH 5. FUNDING...Approved for public release. Distribution is unlimited. UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH Thomas Driscoll, Lieutenant...UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH ABSTRACT The purpose of this MBA report is to explore and understand the issues

  10. Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition

    Directory of Open Access Journals (Sweden)

    Valverde Israel

    2012-04-01

    Full Text Available Abstract Background Systemic-to-pulmonary collateral flow (SPCF may constitute a risk factor for increased morbidity and mortality in patients with single-ventricle physiology (SV. However, clinical research is limited by the complexity of multi-vessel two-dimensional (2D cardiovascular magnetic resonance (CMR flow measurements. We sought to validate four-dimensional (4D velocity acquisition sequence for concise quantification of SPCF and flow distribution in patients with SV. Methods 29 patients with SV physiology prospectively underwent CMR (1.5 T (n = 14 bidirectional cavopulmonary connection [BCPC], age 2.9 ± 1.3 years; and n = 15 Fontan, 14.4 ± 5.9 years and 20 healthy volunteers (age, 28.7 ± 13.1 years served as controls. A single whole-heart 4D velocity acquisition and five 2D flow acquisitions were performed in the aorta, superior/inferior caval veins, right/left pulmonary arteries to serve as gold-standard. The five 2D velocity acquisition measurements were compared with 4D velocity acquisition for validation of individual vessel flow quantification and time efficiency. The SPCF was calculated by evaluating the disparity between systemic (aortic minus caval vein flows and pulmonary flows (arterial and venour return. The pulmonary right to left and the systemic lower to upper body flow distribution were also calculated. Results The comparison between 4D velocity and 2D flow acquisitions showed good Bland-Altman agreement for all individual vessels (mean bias, 0.05±0.24 l/min/m2, calculated SPCF (−0.02±0.18 l/min/m2 and significantly shorter 4D velocity acquisition-time (12:34 min/17:28 min,p 2; Fontan 0.62±0.82 l/min/m2 and not in controls (0.01 + 0.16 l/min/m2, (3 inverse relation of right/left pulmonary artery perfusion and right/left SPCF (Pearson = −0.47,p = 0.01 and (4 upper to lower body flow distribution trend related to the weight (r = 0.742, p  Conclusions 4D

  11. The locking and unlocking thresholds for tearing modes in a cylindrical tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Wenlong [CAS Key Laboratory of Geospace Environment and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Zhu, Ping, E-mail: pzhu@ustc.edu.cn [CAS Key Laboratory of Geospace Environment and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States)

    2016-03-15

    The locking and unlocking thresholds for tearing modes are in general different. In this work, the physics origin for this difference is illustrated from theory analysis, and a numerical procedure is developed to find both locking and unlocking thresholds. In particular, a new scaling law for the unlocking threshold that is valid in both weak and strong rotation regimes has been derived from the lowest amplitude of the RMP (resonant magnetic perturbation) allowed for the locked-mode solution. Above the unlocking threshold, the criterion for the phase-flip instability is extended to identify the entire locked-mode states. Two different regimes of the RMP amplitude in terms of the accessibility of the locked-mode states have been found. In the first regime, the locked-mode state may or may not be accessible depending on the initial conditions of an evolving island. In the second regime, the locked-mode state can always be reached regardless of the initial conditions of the tearing mode. The lowest RMP amplitude for the second regime is determined to be the mode-locking threshold. The different characteristics of the two regimes above the unlocking threshold reveal the underlying physics for the gap between the locking and unlocking thresholds and provide an explanation for the closely related and widely observed hysteresis phenomena in island evolution during the sweeping process of the RMP amplitude up and down across that threshold gap.

  12. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system.

    Science.gov (United States)

    Cao, Jing; Edwards, Rachel; Chairez, Janette; Devaraj, Sridevi

    2017-12-01

    Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

  13. Transverse multibunch modes for non-rigid bunches, including mode coupling

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J S; Ruth, R D [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    A method for computing transverse multibunch growth rates and frequency shifts in rings, which has been described previously, is applied to the PEP-II B factory. The method allows multibunch modes with different internal-bunch oscillation modes to couple to one another, similar to single-bunch mode coupling. Including coupling between the multibunch modes gives effects similar to those seen in single-bunch mode coupling. These effects occur at currents that are lower than the single-bunch mode coupling threshold. (author)

  14. H-mode physics

    International Nuclear Information System (INIS)

    Itoh, Sanae.

    1991-06-01

    After the discovery of the H-mode in ASDEX ( a tokamak in Germany ) the transition between the L-mode ( Low confinement mode ) and H-mode ( High confinement mode ) has been observed in many tokamaks in the world. The H-mode has made a breakthrough in improving the plasma parameters and has been recognized to be a universal phenomena. Since its discovery, the extensive studies both in experiments and in theory have been made. The research on H-mode has been casting new problems of an anomalous transport across the magnetic surface. This series of lectures will provide a brief review of experiments for explaining H-mode and a model theory of H-mode transition based on the electric field bifurcation. If the time is available, a new theoretical model of the temporal evolution of the H-mode will be given. (author)

  15. Hardware Timestamping for an Image Acquisition System Based on FlexRIO and IEEE 1588 v2 Standard

    Science.gov (United States)

    Esquembri, S.; Sanz, D.; Barrera, E.; Ruiz, M.; Bustos, A.; Vega, J.; Castro, R.

    2016-02-01

    Current fusion devices usually implement distributed acquisition systems for the multiple diagnostics of their experiments. However, each diagnostic is composed by hundreds or even thousands of signals, including images from the vessel interior. These signals and images must be correctly timestamped, because all the information will be analyzed to identify plasma behavior using temporal correlations. For acquisition devices without synchronization mechanisms the timestamp is given by another device with timing capabilities when signaled by the first device. Later, each data should be related with its timestamp, usually via software. This critical action is unfeasible for software applications when sampling rates are high. In order to solve this problem this paper presents the implementation of an image acquisition system with real-time hardware timestamping mechanism. This is synchronized with a master clock using the IEEE 1588 v2 Precision Time Protocol (PTP). Synchronization, image acquisition and processing, and timestamping mechanisms are implemented using Field Programmable Gate Array (FPGA) and a timing card -PTP v2 synchronized. The system has been validated using a camera simulator streaming videos from fusion databases. The developed architecture is fully compatible with ITER Fast Controllers and has been integrated with EPICS to control and monitor the whole system.

  16. Natural Frequencies and Mode Shapes of Statically Deformed Inclined Risers

    KAUST Repository

    Alfosail, Feras

    2016-10-15

    We investigate numerically the linear vibrations of inclined risers using the Galerkin approach. The riser is modeled as an Euler-Bernoulli beam accounting for the nonlinear mid-plane stretching and self-weight. After solving for the initial deflection of the riser due to self-weight, we use a Galerkin expansion employing 15 axially loaded beam mode shapes to solve the eigenvalue problem of the riser around the static equilibrium configuration. This yields the riser natural frequencies and corresponding exact mode shapes for various values of inclination angles and tension. The obtained results are validated against a boundary-layer analytical solution and are found to be in good agreement. This constitutes a basis to study the nonlinear forced vibrations of inclined risers.

  17. Identification of surface species by vibrational normal mode analysis. A DFT study

    Science.gov (United States)

    Zhao, Zhi-Jian; Genest, Alexander; Rösch, Notker

    2017-10-01

    Infrared spectroscopy is an important experimental tool for identifying molecular species adsorbed on a metal surface that can be used in situ. Often vibrational modes in such IR spectra of surface species are assigned and identified by comparison with vibrational spectra of related (molecular) compounds of known structure, e. g., an organometallic cluster analogue. To check the validity of this strategy, we carried out a computational study where we compared the normal modes of three C2Hx species (x = 3, 4) in two types of systems, as adsorbates on the Pt(111) surface and as ligands in an organometallic cluster compound. The results of our DFT calculations reproduce the experimental observed frequencies with deviations of at most 50 cm-1. However, the frequencies of the C2Hx species in both types of systems have to be interpreted with due caution if the coordination mode is unknown. The comparative identification strategy works satisfactorily when the coordination mode of the molecular species (ethylidyne) is similar on the surface and in the metal cluster. However, large shifts are encountered when the molecular species (vinyl) exhibits different coordination modes on both types of substrates.

  18. Data acquisition techniques using PC

    CERN Document Server

    Austerlitz, Howard

    1991-01-01

    Data Acquisition Techniques Using Personal Computers contains all the information required by a technical professional (engineer, scientist, technician) to implement a PC-based acquisition system. Including both basic tutorial information as well as some advanced topics, this work is suitable as a reference book for engineers or as a supplemental text for engineering students. It gives the reader enough understanding of the topics to implement a data acquisition system based on commercial products. A reader can alternatively learn how to custom build hardware or write his or her own software.

  19. Acquisition IT Integration

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Øhrgaard, Christian

    2015-01-01

    of temporary agency workers. Following an analytic induction approach, theoretically grounded in the re-source-based view of the firm, we identify the complimentary and supplementary roles consultants can assume in acquisition IT integration. Through case studies of three acquirers, we investigate how...... the acquirers appropriate the use of agency workers as part of its acquisition strategy. For the investigated acquirers, assigning roles to agency workers is contingent on balancing the needs of knowledge induction and knowledge retention, as well as experience richness and in-depth under-standing. Composition...

  20. Mode-to-mode energy transfers in convective patterns

    Indian Academy of Sciences (India)

    Abstract. We investigate the energy transfer between various Fourier modes in a low- dimensional model for thermal convection. We have used the formalism of mode-to-mode energy transfer rate in our calculation. The evolution equations derived using this scheme is the same as those derived using the hydrodynamical ...