WorldWideScience

Sample records for acoustic tumour detection

  1. Tumour response and morphological changes of acoustic neurinomas after radiosurgery

    International Nuclear Information System (INIS)

    Valentino, V.; Raimondi, A.J.

    1995-01-01

    Twenty-seven of the 1560 patients treated by radiosurgery during the period 1984-1993 had acoustic neurinomas. Four cases were excluded from this study because they had a follow-up of less than 2 years. There were 24 neurinomas treated in 23 patients as one patient had a bilateral tumour. Seven patients underwent radiosurgery for a recurrent tumour (already operated on once or twice), while it was the first treatment for 16 patients. The tumour volume ranged from 1.99 cm 3 to 18.30 cm 3 , and the patient follow-up was from 2 to 8 years. To determine the target on CT/NMR for linear accelerator stereotactic irradiation, the Greitz-Bergstroem non-invasive head fixation device was used. It was again adopted for subsequent serial imaging, and for repeat radiosurgery when necessary. The total peripheral tumour dose ranged from 12 to 45 Gy. In 9 patients there was a reduction in tumour volume varying from 39 to 100% , while 14 of the neurinomas appeared stable after an average follow-up of 3 years. In one patient there was an increase in size of the tumour. Variable morphological changes were present in 66% of the neurinomas treated. Radiosurgery is indicated as an alternative to microsurgery for inoperab1e patients and for those who refuse surgery, for recurrent tumours, and as a post-operative complementary treatment for partially removed tumours. A gradual approach to radiosurgery, depending on tumour response, allows a greater efficacy with minimal risk. In the present series no complications were observed. Hearing was preserved at almost the same level as that prior to radiosurgery in all patients. (author)

  2. Detection of apoptotic cells in tumour paraffin sections

    International Nuclear Information System (INIS)

    Pizem, J.; Coer, A.

    2003-01-01

    Apoptosis is a distinct form of cell death characterised by specific morphological features and regulated by complex molecular mechanisms. Its deregulation is fundamental for tumour growth and progression and, moreover, anticancer therapies suppress tumour growth mainly by induction of apoptosis. Since the extent of apoptosis in a tumour may have prognostic as well as therapeutic implications, much effort has been invested in developing specific methods that can be routinely used to detect apoptotic cells in archival formalin- fixed paraffin-embedded tissue. Complex molecular pathways are involved in the regulation of apoptosis. Pro-apoptotic signals trigger activation of caspases that specifically cleave target proteins. Cleavage of proteins (caspase substrates) is responsible for morphological changes of apoptotic cells and DNA fragmentation. In the last decade, detection of apoptotic cells in formalin-fixed tumour tissue sections has been based mainly on morphology and characteristic DNA fragmentation. Recently, specific antibodies to activated caspases and cleaved target proteins (including cytokeratin 18, actin and PARP) have been produced that enable accurate detection of apoptosis in paraffin sections. (author)

  3. Organising haematoma mimicking tumour on MRI following resection of acoustic neuroma

    International Nuclear Information System (INIS)

    Higgins, J.N.P.; Pigeon, C.N.; Moseley, I.F.

    1995-01-01

    We describe a 26-year-old woman in whom an enhancing, intradural extramedullary mass was found at the craniocervical junction on MRI 3 years after resection of a large acoustic neuroma. The radiological appearances suggested a new tumour, raising the possibility of neurofibromatosis 2, provoking a review of family members in an attempt to confirm the diagnosis, as well as further surgery. Histology of the lesion revealed an organising haematoma, with no evidence of malignancy. The imaging features can be explained by the process by which blood clot in the subarachnoid space is resorbed. Caution is advised in interpreting CT or MRI after neurosurgery. (orig.)

  4. The deep sea Acoustic Detection system AMADEUS

    International Nuclear Information System (INIS)

    Naumann, Christopher Lindsay

    2008-01-01

    As a part of the ANTARES neutrino telescope, the AMADEUS (ANTARES Modules for Acoustic Detection Under the Sea) system is an array of acoustical sensors designed to investigate the possibilities of acoustic detection of ultra-high energy neutrinos in the deep sea. The complete system will comprise a total of 36 acoustic sensors in six clusters on two of the ANTARES detector lines. With an inter-sensor spacing of about one metre inside the clusters and between 15 and 340 metres between the different clusters, it will cover a wide range of distances as will as provide a considerable lever arm for point source triangulation. Three of these clusters have already been deployed in 2007 and have been in operation since, currently yielding around 2GB of acoustic data per day. The remaining three clusters are scheduled to be deployed in May 2008 together with the final ANTARES detector line. Apart from proving the feasibility of operating an acoustic detection system in the deep sea, the main aim of this project is an in-depth survey of both the acoustic properties of the sea water and the acoustic background present at the detector site. It will also serve as a platform for the development and refinement of triggering, filtering and reconstruction algorithms for acoustic particle detection. In this presentation, a description of the acoustic sensor and read-out system is given, together with examples for the reconstruction and evaluation of the acoustic data.

  5. Acoustic Particle Detection with the ANTARES Detector

    Directory of Open Access Journals (Sweden)

    M. Neff

    2010-01-01

    Full Text Available The (Antares Modules for Acoustic Detection Under the Sea AMADEUS system within the (Astronomy with a Neutrino Telescope and Abyss environmental RESsearch ANTARES neutrino telescope is designed to investigate detection techniques for acoustic signals produced by particle cascades. While passing through a liquid a cascade deposits energy and produces a measurable pressure pulse. This can be used for the detection of neutrinos with energies exceeding 1018 eV. The AMADEUS setup consists of 36 hydrophones grouped in six local clusters measuring about one cubic meter each. This article focuses on acoustic particle detection, the hardware of the AMADEUS detector and techniques used for acoustic signal processing.

  6. Acoustic Particle Detection with the ANTARES Detector

    Directory of Open Access Journals (Sweden)

    Richardt C

    2010-01-01

    Full Text Available The (Antares Modules for Acoustic Detection Under the Sea AMADEUS system within the (Astronomy with a Neutrino Telescope and Abyss environmental RESsearch ANTARES neutrino telescope is designed to investigate detection techniques for acoustic signals produced by particle cascades. While passing through a liquid a cascade deposits energy and produces a measurable pressure pulse. This can be used for the detection of neutrinos with energies exceeding  eV. The AMADEUS setup consists of 36 hydrophones grouped in six local clusters measuring about one cubic meter each. This article focuses on acoustic particle detection, the hardware of the AMADEUS detector and techniques used for acoustic signal processing.

  7. Acoustic detection of pneumothorax

    Science.gov (United States)

    Mansy, Hansen A.; Royston, Thomas J.; Balk, Robert A.; Sandler, Richard H.

    2003-04-01

    This study aims at investigating the feasibility of using low-frequency (pneumothorax detection were tested in dogs. In the first approach, broadband acoustic signals were introduced into the trachea during end-expiration and transmitted waves were measured at the chest surface. Pneumothorax was found to consistently decrease pulmonary acoustic transmission in the 200-1200-Hz frequency band, while less change was observed at lower frequencies (ppneumothorax states (pPneumothorax was found to be associated with a preferential reduction of sound amplitude in the 200- to 700-Hz range, and a decrease of sound amplitude variation (in the 300 to 600-Hz band) during the respiration cycle (pPneumothorax changed the frequency and decay rate of percussive sounds. These results imply that certain medical conditions may be reliably detected using appropriate acoustic measurements and analysis. [Work supported by NIH/NHLBI #R44HL61108.

  8. A Correlated Active Acoustic Leak Detection in a SFR Steam Generator

    International Nuclear Information System (INIS)

    Kim, Tae Joon; Jeong, Ji Young; Kim, Jong Man; Kim, Byung Ho; Kim, Yong Il

    2009-01-01

    The methods of acoustic leak detection are active acoustic leak detection and passive acoustic leak detection. The methods for passive acoustic leak detection are already established, but because our goal is development of passive acoustic leak detection for detecting a leakage range of small and micro leak rates, it is difficult detecting a leak in steam generator using this developed passive acoustic leak detection. Thus the acoustic leak detection system is required to be able to detect wide range of water leaks. From this view point we need to develop an active acoustic leak detection technology to be able to detect intermediate leak rates

  9. Acoustic leak detection in nuclear power plants

    International Nuclear Information System (INIS)

    McElroy, J.W.

    1986-01-01

    For several years now, utilities have been utilizing acoustic leak detection methods as an operating tool in their nuclear power stations. The purpose for using the leak detection system at the various stations vary from safety, ALARA, improved operations, preventive maintenance, or increased plant availability. This paper describes the various acoustic techniques and their application. The techniques are divided into three categories: specific component leakage, intersystem leakage, and pipe through-wall crack leakage. The paper addresses each category in terms of motivation to monitor, method of application and operation, and benefits to be gained. Current requirements are reviewed and analyzed with respect to the acoustic techniques. The paper shows how acoustic leak detection is one of the most effective leak detection tools available. 9 figures, 1 table

  10. The acoustic detection of cavitation in pumps

    International Nuclear Information System (INIS)

    Macleod, I.D.; Gray, B.S.; Taylor, C.G.

    1978-01-01

    A programme was initiated to develop a reliable technique for detecting the onset of acoustic noise from cavitation in a pump and to relate this to cavitation inception data, since significant noise from collapse of vapour bubbles arising from such cavitation would reduce the sensitivity of a noise detection system for boiling of sodium in fast breeder reactors. Factors affecting the detection of cavitation are discussed. The instrumentation and techniques of frequency analysis and pulse detection are described. Two examples are then given of the application of acoustic detection techniques under controlled conditions. It is concluded that acoustic detection can be a reliable method for detecting inception of cavitation in a pump and the required conditions are stated. (U.K.)

  11. Acoustic change detection algorithm using an FM radio

    Science.gov (United States)

    Goldman, Geoffrey H.; Wolfe, Owen

    2012-06-01

    The U.S. Army is interested in developing low-cost, low-power, non-line-of-sight sensors for monitoring human activity. One modality that is often overlooked is active acoustics using sources of opportunity such as speech or music. Active acoustics can be used to detect human activity by generating acoustic images of an area at different times, then testing for changes among the imagery. A change detection algorithm was developed to detect physical changes in a building, such as a door changing positions or a large box being moved using acoustics sources of opportunity. The algorithm is based on cross correlating the acoustic signal measured from two microphones. The performance of the algorithm was shown using data generated with a hand-held FM radio as a sound source and two microphones. The algorithm could detect a door being opened in a hallway.

  12. Comparison of somatostatin analogue and metaiodobenzylguanidine scintigraphy for the detection of carcinoid tumours

    International Nuclear Information System (INIS)

    Nocaudie-Calzada, M.; Huglo, D.; Carnaille, B.; Proye, C.; Marchandise, X.

    1996-01-01

    The purpose of this prospective study was to compare the ability of radiolabelled somatostatin analogue (RSA) and metaiodobenzylguanidine (MIBG) scintigraphy to display carcinoid tumours. Forty patients were studied after radiological assessment based on clinical symptomatology. These patients had radiologically demonstrated tumours (n=28), resected tumours discovered to be of the carcinoid type (n=5) or clinically and biologically suspected carcinoid tumours (n=7). They underwent indium-111 DTPA-pentetreotide or iodine-123-Tyr-3-octreotide and 131 I-MIBG scintigraphy. The results were compared with those of complementary surgical or morphological examinations and analysed according to the site of the tumour and the symptomatology. In the case of 31 patients with a total of 55 tumoral sites, the sensitivity of the initial radiological assessment, of RSA and of MIBG was 96%, 86% and 64%, respectively, for the detection of at least one tumour per patient, but 51%, 85% and 51%, respectively, for the total number of sites. No site was detected solely by MIBG. The concordance between RSA and MIBG was better when all sites were considered (kappa index+0.44) than for only extrahepatic abdominal tumoral sites (kappa index+0.095). Abdominal, thoracic or bone marrow tumours were more easily detected with RSA than with MIBG. Hepatic invasion (21 cases) was more easily detected by radiology (sensitivity 100%) than by RSA and MIBG, both of which displayed a sensitivity of 80%, but with differences in uptake intensity. Tumour detection using MIBG was more significantly linked with flush (P 0.10). In the assessment of carcinoid tumours, RSA scintigraphy should be carried out initially (just after hepatic ultrasonography) and supplemented by MIBG, as comparison of the studies serves to guide therapeutic options and might be valuable for prognosis. (orig.). With 2 figs., 3 tabs

  13. Cardiac tumours: non invasive detection and assessment by gated cardiac blood pool radionuclide imaging

    International Nuclear Information System (INIS)

    Pitcher, D.; Wainwright, R.; Brennand-Roper, D.; Deverall, P.; Sowton, E.; Maisey, M.

    1980-01-01

    Four patients with cardiac tumours were investigated by gated cardiac blood pool radionuclide imaging and echocardiography. Contrast angiocardiography was performed in three of the cases. Two left atrial tumours were detected by all three techniques. In one of these cases echocardiography alone showed additional mitral valve stenosis, but isotope imaging indicated tumour size more accurately. A large septal mass was detected by all three methods. In this patient echocardiography showed evidence of left ventricular outflow obstruction, confirmed at cardiac catheterisation, but gated isotope imaging provided a more detailed assessment of the abnormal cardiac anatomy. In the fourth case gated isotope imaging detected a large right ventricular tumour which had not been identified by echocardiography. Gated cardiac blood pool isotope imaging is a complementary technique to echocardiography for the non-invasive detection and assessment of cardiac tumours. (author)

  14. Acoustic leak detection of LMFBR steam generator

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Yoshida, Kazuo

    1993-01-01

    The development of a water leak detector with short response time for LMFBR steam generators is required to prevent the failure propagation caused by the sodium-water reaction and to maintain structural safety in steam generators. The development of an acoustic leak detector assuring short response time has attracted. The purpose of this paper is to confirm the basic detection feasibility of the active acoustic leak detector, and to investigate the leak detection method by erasing the background noise by spectrum analysis of the passive acoustic leak detector. From a comparison of the leak detection sensitivity of the active and the passive method, the active method is not influenced remarkably by the background noise, and it has possibility to detect microleakage with short response time. We anticipate a practical application of the active method in the future. (author)

  15. Golden Gate and Pt. Reyes Acoustic Detections

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains detections of acoustic tagged fish from two general locations: Golden Gate (east and west line) and Pt. Reyes. Several Vemco 69khz acoustic...

  16. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Horomichi

    1990-01-01

    The purpose of this study is to estimate the availability of acoustic method for detecting the internal leakage of valves at power plants. Experiments have been carried out on the characteristics of acoustic noise caused by the leak simulated flow. From the experimental results, the mechanism of the acoustic noisegenerated from flow, the relation between acoustic intensity and leak flow velocity, and the characteristics of the acoustic frequency spectrum were clarified. The acoustic method was applied to valves at site, and the background noises were measured in abnormal plant conditions. When the background level is higher than the acoustic signal, the difference between the background noise frequency spectrum and the acoustic signal spectrum provide a very useful leak detection method. (author)

  17. Structural Acoustic UXO Detection and Identification in Marine Environments

    Science.gov (United States)

    2016-05-01

    a thick steel wall, is cylindrical, and has an aspect ratio of about 5:1. Further, the interior water can support acoustic waves as does the epoxy...FINAL REPORT Structural Acoustic UXO Detection and Identification in Marine Environments SERDP Project MR-2103 MAY 2016 B. H...NUMBER Structural Acoustic UXO Detection and Identification in Marine Environments- Final report for Follow-on Work- MR-2103 Sb. GRANT NUMBER Sc

  18. PLASTIC PIPE DEFECT DETECTION USING NONLINEAR ACOUSTIC MODULATION

    Directory of Open Access Journals (Sweden)

    Gigih Priyandoko

    2015-02-01

    Full Text Available This project discuss about the defect detection of plastic pipe by using nonlinear acoustic wave modulation method. Nonlinaer acoustic modulations are investigated for fatigue crack detection. It is a sensitive method for damage detection and it is based on the propagation of high frequency acoustic waves in plastic pipe with low frequency excitation. The plastic pipe is excited simultaneously with a slow amplitude modulated vibration pumping wave and a constant amplitude probing wave. The frequency of both the excitation signals coincides with the resonances of the plastic pipe. An actuator is used for frequencies generation while sensor is used for the frequencies detection. Besides that, a PVP pipe is used as the specimen as it is commonly used for the conveyance of liquid in many fields. The results obtained are being observed and the difference between uncrack specimen and cracked specimen can be distinguished.

  19. Radiofrequency ablation of renal tumours: diagnostic accuracy of contrast-enhanced ultrasound for early detection of residual tumour

    International Nuclear Information System (INIS)

    Hoeffel, Christine; Pousset, Maud; Elie, Caroline; Timsit, Marc-Olivier; Mejean, Arnaud; Merran, Samuel; Tranquart, Francois; Khairoune, Ahmed; Helenon, Olivier; Correas, Jean-Michel; Joly, Dominique; Richard, Stephane

    2010-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in the early detection of residual tumour after radiofrequency ablation (RFA) of renal tumours. Patients referred to our institution for RFA of renal tumours prospectively underwent CEUS and computed tomography (CT) or magnetic resonance imaging (MRI) before, within 1 day and 6 weeks after treatment. Identification of residual tumour was assessed by three blinded radiologists. Reference standard was CT/MRI performed at least 1 year after RFA. A total of 66 renal tumours in 43 patients (median age 62 years; range 44-71.5) were studied. Inter-reader agreement (κ value) was 0.84 for CEUS. Prevalence of residual disease was 19%. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), respectively, were as follows: 64% [confidence interval (CI) 39-84], 98% [CI 91-100], 82% [CI 52-95] and 92% [CI 83-97] on 24-h CEUS; 79% [CI 52-92], 100% [CI 94-100], 100% [CI 74-100] and 95% [CI 87-100] on 6-week CEUS; 79% [CI 52-92], 95% [CI 86-98], 79% [CI 52-92] and 95% [CI 86-98] on 24-h CT/MRI; and 100% [CI 72-100], 98% [CI 90-100], 91% [CI 62-98] and 100% [CI 93-100] on 6-week CT/MRI. CEUS has high specificity for the early diagnosis of residual tumour after renal RFA. (orig.)

  20. SU-E-T-14: A Comparative Study Between Forward and Inverse Planning in Gamma Knife Radiosurgery for Acoustic Neuroma Tumours

    Energy Technology Data Exchange (ETDEWEB)

    Gopishankar, N; Agarwal, Priyanka; Bisht, Raj Kishor; Kale, S S; Rath, G K; Chander, S; Sharma, B S [All India Institute of Medical Sciences, New Delhi (India)

    2015-06-15

    Purpose: To evaluate forward and inverse planning methods for acoustic neuroma cases treated in Gamma Knife Perfexion. Methods: Five patients with acoustic neuroma tumour abutting brainstem were planned twice in LGP TPS (Version 10.1) using TMR10 algorithm. First plan was entirely based on forward planning (FP) in which each shot was chosen manually. Second plan was generated using inverse planning (IP) for which planning parameters like coverage, selectivity, gradient index (GI) and beam-on time threshold were set. Number of shots in IP was automatically selected by objective function using iterative process. In both planning methods MRI MPRAGE sequence images were used for tumour localization and planning. A planning dose of 12Gy at 50% isodose level was chosen. Results and Discussion: Number of shots used in FP was greater than IP and beam-on time in FP was in average 1.4 times more than IP. One advantage of FP was that the brainstem volume subjected to 6Gy dose (25% isodose) was less in FP than IP. Our results showed use of more number of shots as in FP results in GI less than or equal to 2.55 which is close to its lower limit. Dose homogeneity index (DHI) analysis of FP and IP showed average values of 0.59 and 0.67 respectively. General trend in GK for planning in acoustic neuroma cases is to use small collimator shots to avoid dose to adjacent critical structures. More number of shots and prolonged treatment time causes inconvenience to the patients. Similarly overuse of automatic shot shaping as in IP results in increased scatter dose. A compromise is required in shot selection for these cases. Conclusion: IP method could be used in acoustic neuroma cases to decrease treatment time provided the source sector openings near brainstem are shielded or adjusted appropriately to reduce brainstem dose.

  1. Ultrasound compared with computed tomography and pancreatic arteriography in the detection of endocrine tumours of the pancreas

    International Nuclear Information System (INIS)

    Paeivaensalo, M.; Maekaeraeinen, H.; Siniluoto, T.; Staahlberg, M.; Jalovaara, P.; Oulu Univ. Central Hospital

    1989-01-01

    We have evaluated ultrasound, computed tomography and arteriographic findings in 15 patients with 17 endocrine pancreatic tumours having a mean diameter of 2.3 cm (range 1-7 cm). All patients underwent computed tomography, and all but one ultrasound and arteriography. Ultrasound was the initial investigation in 11 patients, and identified 10 of the 16 tumours present in 14 patients. Two tumours were found at ultrasound reexamination after having been identified by other radiological methods. Computed tomography revealed 8 out of 17 tumours, while arteriography identified 8 out of 16 tumours. Computed tomography was the initial investigation in 4 patients,and identified one tumour. In only 4 patients were tumours not detected by any of the imaging methods. The sensitivities of ultrasound, computed tomography and arteriography in the detection of pancreatic tumours were 62.5% (95% confidence interval 50.4-74.6%), 47.1% (95% confidence interval 35.0-59.2%), and 50.0% (95% confidence interval 37.5-62.5%), respectively. Ultrasound was thus more accurate than computed tomography or arteriography in detecting endocrine pancreatic tumours, and should be the initial radiological investigation. (orig.)

  2. Laser-induced acoustic landmine detection with experimental results on buried landmines

    NARCIS (Netherlands)

    Heuvel, J.C. van den; Putten, F.J.M. van; Koersel, A.C. van; Schleijpen, H.M.A.

    2004-01-01

    Acoustic landmine detection (ALD) is a technique for the detection of buried landmines including non-metal mines. Since it gives complementary results with GPR or metal detection, sensor fusion of these techniques with acoustic detection would give promising results. Two methods are used for the

  3. Tumour imaging by the detection of fibrin clots in tumour stroma using an anti-fibrin Fab fragment

    Science.gov (United States)

    Obonai, Toshifumi; Fuchigami, Hirobumi; Furuya, Fumiaki; Kozuka, Naoyuki; Yasunaga, Masahiro; Matsumura, Yasuhiro

    2016-01-01

    The diagnosis of early and aggressive types of cancer is important for providing effective cancer therapy. Cancer-induced fibrin clots exist only within lesions. Previously, we developed a monoclonal antibody (clone 102-10) that recognizes insoluble fibrin but not fibrinogen or soluble fibrin and confirmed that fibrin clots form continuously in various cancers. Here, we describe the development of a Fab fragment probe of clone 102-10 for tumour imaging. The distribution of 102-10 Fab was investigated in genetically engineered mice bearing pancreatic ductal adenocarcinoma (PDAC), and its effect on blood coagulation was examined. Immunohistochemical and ex vivo imaging revealed that 102-10 Fab was distributed selectively in fibrin clots in PDAC tumours 3 h after injection and that it disappeared from the body after 24 h. 102-10 Fab had no influence on blood coagulation or fibrinolysis. Tumour imaging using anti-fibrin Fab may provide a safe and effective method for the diagnosis of invasive cancers by detecting fibrin clots in tumour stroma. PMID:27009516

  4. Topography and biological noise determine acoustic detectability on coral reefs

    KAUST Repository

    Cagua, Edgar F.; Berumen, Michael L.; Tyler, Elizabeth

    2013-01-01

    Acoustic telemetry is an increasingly common tool for studying the movement patterns, behavior and site fidelity of marine organisms, but to accurately interpret acoustic data, the variability, periodicity and range of detectability between acoustic

  5. Development of acoustic leak detection system in PNC

    International Nuclear Information System (INIS)

    Tanabe, H.; Kuroha, M.

    1990-01-01

    The development of an acoustic leak detector is under way at PNC as a detection system that has potential of quick response and high reliability for larger steam generators of future LMFBR plants. The studies have two aspects, i.e., an acoustic wave analysis in various sodium-water reactions and a background noise (BGN) analysis in a sodium-heated 50MWt steam generator (50MWGS). In the former analysis, wave profiles of the sodium-water reaction sound were analyzed and compared with those of inert gas injection sound. The comparison revealed that there were no wave profiles specific to a sodium-water reaction sound. The latter clarified that major acoustic sources in the steam generator were sodium flow and steam generation/flow and that the water leak rate at which a noise level was comparable with that of the background noise was about 0.5 g/sec. in the evaporator of 50MWSG. The estimation of acceleration levels of BGN and leak sounds in other plants reveals that an intermediate leak is detectable in the Monju evaporator with a present acoustic detection system. (author). 2 refs, 9 figs

  6. Signal classification for acoustic neutrino detection

    International Nuclear Information System (INIS)

    Neff, M.; Anton, G.; Enzenhöfer, A.; Graf, K.; Hößl, J.; Katz, U.; Lahmann, R.; Richardt, C.

    2012-01-01

    This article focuses on signal classification for deep-sea acoustic neutrino detection. In the deep sea, the background of transient signals is very diverse. Approaches like matched filtering are not sufficient to distinguish between neutrino-like signals and other transient signals with similar signature, which are forming the acoustic background for neutrino detection in the deep-sea environment. A classification system based on machine learning algorithms is analysed with the goal to find a robust and effective way to perform this task. For a well-trained model, a testing error on the level of 1% is achieved for strong classifiers like Random Forest and Boosting Trees using the extracted features of the signal as input and utilising dense clusters of sensors instead of single sensors.

  7. Acoustic detection of high energy neutrinos in sea water: status and prospects

    Directory of Open Access Journals (Sweden)

    Lahmann Robert

    2017-01-01

    Full Text Available The acoustic neutrino detection technique is a promising approach for future large-scale detectors with the aim of measuring the small expected flux of neutrinos at energies in the EeV-range and above. The technique is based on the thermo-acoustic model, which implies that the energy deposition by a particle cascade – resulting from a neutrino interaction in a medium with suitable thermal and acoustic properties – leads to a local heating and a subsequent characteristic pressure pulse that propagates in the surrounding medium. Current or recent test setups for acoustic neutrino detection have either been add-ons to optical neutrino telescopes or have been using acoustic arrays built for other purposes, typically for military use. While these arrays have been too small to derive competitive limits on neutrino fluxes, they allowed for detailed studies of the experimental technique. With the advent of the research infrastructure KM3NeT in the Mediterranean Sea, new possibilities will arise for acoustic neutrino detection. In this article, results from the “first generation” of acoustic arrays will be summarized and implications for the future of acoustic neutrino detection will be discussed.

  8. A Four-Quadrant PVDF Transducer for Surface Acoustic Wave Detection

    Directory of Open Access Journals (Sweden)

    Zhi Chen

    2012-08-01

    Full Text Available In this paper, a polyvinylidene fluoride (PVDF piezoelectric transducer was developed to detect laser-induced surface acoustic waves in a SiO2-thin film–Si-substrate structure. In order to solve the problems related to, firstly, the position of the probe, and secondly, the fact that signals at different points cannot be detected simultaneously during the detection process, a four-quadrant surface acoustic wave PVDF transducer was designed and constructed for the purpose of detecting surface acoustic waves excited by a pulse laser line source. The experimental results of the four-quadrant piezoelectric detection in comparison with the commercial nanoindentation technology were consistent, the relative error is 0.56%, and the system eliminates the piezoelectric surface wave detection direction deviation errors, improves the accuracy of the testing system by 1.30%, achieving the acquisition at the same time at different testing positions of the sample.

  9. Radiological diagnosis of liver tumours

    International Nuclear Information System (INIS)

    Lundstedt, C.

    1987-01-01

    Sixty patients treated with an intra-arterial cytostatic drug for metastases from colo-rectal carcinoma were evaluated with angiography to determine prognostic parameters. The extent of tumour in the liver and an unchanged or diminished tumour volume following treatment, as demonstrated with angiography, were associated with significant prolongation of survival. Patients who developed occlusion of the hepatic artery or of branches of the portal vein, also survived longer. 189 patients examined with angiography, 161 with computed tomography (CT), 95 with computed tomographic arteriography (CTA) and 71 with ultrasound (US) were subjected to liver evaluation at laparotomy consisting of inspection and palpation. The result of this surgical liver evaluation was for the purpose of the study regarded as completely accurate and was used to assess the accuracy of the different radiological methods. The location of tumour in the liver lobes or segments was analysed, with a separate evaluation of the right and left liver lobes. The rate of detection of individual tumour nodules was also determined. Angiography detected 55% of liver areas affected by tumour and 47% of individual tumour nodules. CT detected 83% of liver lobes or segments containing tumour, and 70% of the tumour nodules. US detected 69% of the portions of liver holding tumour, and also 69% of the tumour nodules. CTA detected 85% of tumours areas and 74% of separate tumour nodules. Some lesions detected with CT were not seen with CTA and vice versa. More false-positive results were recorded with CTA than with CT using intravenous contrast enhancement. (orig.)

  10. Detection of human cancer in an animal model using radio-labelled tumour-associated monoclonal antibodies

    International Nuclear Information System (INIS)

    Epenetos, A.A.; Arklie, J.; Knowles, R.W.; Bodmer, W.F.

    1982-01-01

    Monoclonal antibodies to epithelial-cell antigenic determinants, labelled with 123 I and 125 I, were administered parenterally to immunodeficient mice bearing human tumours derived from a human cancer cell line. Anterior, posterior and lateral radioscans of the body were taken with a gamma scintillation camera at various times from immediately to 65 days after injection. Visual displays of the images were processed by standard computer techniques. The model used a human colon-cancer cell line, HT29, and the monoclonal antibody, AUAl, which is specific to an epithelial proliferating antigen. Tumour detection was achieved in all the mice. The smallest tumour detectable appeared to be about 1 mm in diameter. The degree of antibody uptake in a tumour depended on its size and the blood supply of its surrounding tissues. (author)

  11. [Application of PLA Method for Detection of p53/p63/p73 Complexes in Situ in Tumour Cells and Tumour Tissue].

    Science.gov (United States)

    Hrabal, V; Nekulová, M; Nenutil, R; Holčaková, J; Coates, P J; Vojtěšek, B

    2017-01-01

    PLA (proximity ligation assay) can be used for detection of protein-protein interactions in situ directly in cells and tissues. Due to its high sensitivity and specificity it is useful for detection, localization and quantification of protein complexes with single molecule resolution. One of the mechanisms of mutated p53 gain of function is formation of proten-protein complexes with other members of p53 family - p63 and p73. These interactions influences chemosensitivity and invasivity of cancer cells and this is why these complexes are potential targets of anti-cancer therapy. The aim of this work is to detect p53/p63/p73 interactions in situ in tumour cells and tumour tissue using PLA method. Unique in-house antibodies for specific detection of p63 and p73 isoforms were developed and characterized. Potein complexes were detected using PLA in established cell lines SVK14, HCC1806 and FaDu and in paraffin sections of colorectal carcinoma tissue. Cell lines were also processed to paraffin blocks. p53/T-antigen and ΔNp63/T-antigen protein complexes were detected in SVK14 cells using PLA. Interactions of ΔNp63 and TAp73 isoforms were found in HCC1806 cell line with endogenous expression of these proteins. In FaDu cell line mut-p53/TAp73 complex was localized but not mut-p53/ΔNp63 complex. p53 tetramer was detected directly in colorectal cancer tissue. During development of PLA method for detection of protein complexes between p53 family members we detected interactions of p53 and p63 with T-antigen and mut-p53 and ΔNp63 with TAp73 tumour suppressor in tumour cell lines and p53 tetramers in paraffin sections of colorectal cancer tissue. PLA will be further used for detection of p53/p63, p53/p73 and p63/p73 interactions in tumour tissues and it could be also used for screening of compounds that can block formation of p53/p63/p73 protein complexes.Key words: p53 protein family - protein interaction mapping - immunofluorescence This work was supported by MEYS - NPS I

  12. Comparison of CT scan and colour flow doppler ultrasound in detecting venous tumour thrombous in renal cell carcinoma

    International Nuclear Information System (INIS)

    Khan, A.R.; Anwar, K.

    2008-01-01

    Renal cell carcinoma has marked tendency to spread into renal vein, inferior vena cava and right side of heart. Extension of tumour thrombus into these veins will alter the surgical approach. We have compared the CT scan with Colour flow Doppler ultrasound in detecting venous tumour thrombus in renal vein and inferior vena cava. This cross-sectional study included 30 adult patients presenting with renal tumour. Patients of either gender were included in the study. Non probability convenience sampling was used. All patients underwent colour flow Doppler ultrasound and CT scan with contrast to asses the renal vein and inferior vena cava. The results were confirmed by intra operative findings and histopathology. The data was analyzed using SPSS version 12. Out of 30 patients, 20 (66%) were males and 10 (34%) female. The tumour was predominantly on the right side (60%), as was renal venous tumour thrombus (44%). Inferior vena cava was involved in 4 cases predominantly due to right sided tumours. The sensitivity of Doppler ultrasound in detecting renal venous tumour thrombus (88% on right and 100% on left side) was higher than CT scan (63% on right and 60% on left side). Doppler ultrasound was also superior to CT scan in detecting vena caval thrombus. The overall sensitivity of Doppler sonography was higher than CT scan in detecting tumour extension into renal veins and inferior vena cava. Therefore, it can be used as a complementary tool in equivocal cases. (author)

  13. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  14. Diesel Engine Valve Clearance Detection Using Acoustic Emission

    Directory of Open Access Journals (Sweden)

    Fathi Elamin

    2010-01-01

    Full Text Available This paper investigated, using experimental method, the suitability of acoustic emission (AE technique for the condition monitoring of diesel engine valve faults. The clearance fault was adjusted experimentally in an exhaust valve and successfully detected and diagnosed in a Ford FSD 425 four-cylinder, four-stroke, in-line OHV, direct injection diesel engine. The effect of faulty exhaust valve clearance on engine performance was monitored and the difference between the healthy and faulty engine was observed from the recorded AE signals. The measured results from this technique show that using only time domain and frequency domain analysis of acoustic emission signals can give a superior measure of engine condition. This concludes that acoustic emission is a powerful and reliable method of detection and diagnosis of the faults in diesel engines and this is considered to be a unique approach to condition monitoring of valve performance.

  15. Passive acoustic detection of deep-diving beaked whales

    DEFF Research Database (Denmark)

    Zimmer, W.M.X.; Harwood, J.; Tyack, P.L.

    2008-01-01

    Beaked whales can remain submerged for an hour or more and are difficult to sight when they come to the surface to breathe. Passive acoustic detection (PAD) not only complements traditional visual-based methods for detecting these species but also can be more effective because beaked whales produce...... clicks regularly to echolocate on prey during deep foraging dives. The effectiveness of PAD for beaked whales depends not only on the acoustic behavior and output of the animals but also on environmental conditions and the quality of the passive sonar implemented. A primary constraint on the range...... at which beaked whale clicks can be detected involves their high frequencies, which attenuate rapidly, resulting in limited ranges of detection, especially in adverse environmental conditions. Given current knowledge of source parameters and in good conditions, for example, with a wind speed of 2  m...

  16. The optimization of acoustic fields for ablative therapies of tumours in the upper abdomen

    Science.gov (United States)

    Gélat, P.; ter Haar, G.; Saffari, N.

    2012-12-01

    High intensity focused ultrasound (HIFU) enables highly localized, non-invasive tissue ablation and its efficacy has been demonstrated in the treatment of a range of cancers, including those of the kidney, prostate and breast. HIFU offers the ability to treat deep-seated tumours locally, and potentially bears fewer side effects than more invasive treatment modalities such as resection, chemotherapy and ionizing radiation. There remains however a number of significant challenges which currently hinder its widespread clinical application. One of these challenges is the need to transmit sufficient energy through the ribcage to ablate tissue at the required foci whilst minimizing the formation of side lobes and sparing healthy tissue. Ribs both absorb and reflect ultrasound strongly. This sometimes results in overheating of bone and overlying tissue during treatment, leading to skin burns. Successful treatment of a patient with tumours in the upper abdomen therefore requires a thorough understanding of the way acoustic and thermal energy is deposited. Previously, a boundary element approach based on a Generalized Minimal Residual (GMRES) implementation of the Burton-Miller formulation was developed to predict the field of a multi-element HIFU array scattered by human ribs, the topology of which was obtained from CT scan data (Gélat et al 2011 Phys. Med. Biol. 56 5553-81). The present paper describes the reformulation of the boundary element equations as a least-squares minimization problem with nonlinear constraints. The methodology has subsequently been tested at an excitation frequency of 1 MHz on a spherical multi-element array in the presence of ribs. A single array-rib geometry was investigated on which a 50% reduction in the maximum acoustic pressure magnitude on the surface of the ribs was achieved with only a 4% reduction in the peak focal pressure compared to the spherical focusing case. This method was then compared with a binarized apodization approach

  17. Surveillance mammography for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Clare; Boachie, Charles; Fraser, Cynthia; MacLennan, Graeme; Mowatt, Graham; Thomas, Ruth E. [University of Aberdeen, Health Services Research Unit, Aberdeen (United Kingdom); Ragupathy, Senthil Kumar Arcot [NHS Grampian, Radiology Department, Aberdeen Royal Infirmary, Aberdeen (United Kingdom); Heys, Steve D. [University of Aberdeen and Aberdeen Royal Infirmary, NHS Grampian, Division of Applied Medicine, School of Medicine and Dentistry, Aberdeen (United Kingdom); Gilbert, Fiona J. [University of Aberdeen and Aberdeen Royal Infirmary, NHS Grampian, Aberdeen Biomedical Imaging Centre, Aberdeen (United Kingdom)

    2011-12-15

    To determine the diagnostic accuracy of surveillance mammography for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer in women previously treated for primary breast cancer. A systematic review of surveillance mammography compared with ultrasound, magnetic resonance imaging (MRI), specialist-led clinical examination or unstructured primary care follow-up, using histopathological assessment for test positives and follow-up for test negatives as the reference standard. Nine studies met our inclusion criteria. Variations in study comparisons precluded meta-analysis. For routine ipsilateral breast tumour detection, surveillance mammography sensitivity ranged from 64-67% and specificity ranged from 85-97%. For MRI, sensitivity ranged from 86-100% and specificity was 93%. For non-routine ipsilateral breast tumour detection, sensitivity and specificity for surveillance mammography ranged from 50-83% and 57-75% and for MRI 93-100% and 88-96%. For routine metachronous contralateral breast cancer detection, one study reported sensitivity of 67% and specificity of 50% for both surveillance mammography and MRI. Although mammography is associated with high sensitivity and specificity, MRI is the most accurate test for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer in women previously treated for primary breast cancer. Results should be interpreted with caution because of the limited evidence base. (orig.)

  18. Passive acoustic monitoring to detect spawning in large-bodied catostomids

    Science.gov (United States)

    Straight, Carrie A.; Freeman, Byron J.; Freeman, Mary C.

    2014-01-01

    Documenting timing, locations, and intensity of spawning can provide valuable information for conservation and management of imperiled fishes. However, deep, turbid or turbulent water, or occurrence of spawning at night, can severely limit direct observations. We have developed and tested the use of passive acoustics to detect distinctive acoustic signatures associated with spawning events of two large-bodied catostomid species (River Redhorse Moxostoma carinatum and Robust Redhorse Moxostoma robustum) in river systems in north Georgia. We deployed a hydrophone with a recording unit at four different locations on four different dates when we could both record and observe spawning activity. Recordings captured 494 spawning events that we acoustically characterized using dominant frequency, 95% frequency, relative power, and duration. We similarly characterized 46 randomly selected ambient river noises. Dominant frequency did not differ between redhorse species and ranged from 172.3 to 14,987.1 Hz. Duration of spawning events ranged from 0.65 to 11.07 s, River Redhorse having longer durations than Robust Redhorse. Observed spawning events had significantly higher dominant and 95% frequencies than ambient river noises. We additionally tested software designed to automate acoustic detection. The automated detection configurations correctly identified 80–82% of known spawning events, and falsely indentified spawns 6–7% of the time when none occurred. These rates were combined over all recordings; rates were more variable among individual recordings. Longer spawning events were more likely to be detected. Combined with sufficient visual observations to ascertain species identities and to estimate detection error rates, passive acoustic recording provides a useful tool to study spawning frequency of large-bodied fishes that displace gravel during egg deposition, including several species of imperiled catostomids.

  19. Integrated immunoassay using tuneable surface acoustic waves and lensfree detection.

    Science.gov (United States)

    Bourquin, Yannyk; Reboud, Julien; Wilson, Rab; Zhang, Yi; Cooper, Jonathan M

    2011-08-21

    The diagnosis of infectious diseases in the Developing World is technologically challenging requiring complex biological assays with a high analytical performance, at minimal cost. By using an opto-acoustic immunoassay technology, integrating components commonly used in mobile phone technologies, including surface acoustic wave (SAW) transducers to provide pressure driven flow and a CMOS camera to enable lensfree detection technique, we demonstrate the potential to produce such an assay. To achieve this, antibody functionalised microparticles were manipulated on a low-cost disposable cartridge using the surface acoustic waves and were then detected optically. Our results show that the biomarker, interferon-γ, used for the diagnosis of diseases such as latent tuberculosis, can be detected at pM concentrations, within a few minutes (giving high sensitivity at a minimal cost). This journal is © The Royal Society of Chemistry 2011

  20. Innovative Design of a Laparoscopic Probe for Non-Invasive Intraoperative Detection of Small Endoluminal Digestive Tumours

    Directory of Open Access Journals (Sweden)

    Bogdan Mocan

    2015-12-01

    Full Text Available The present paper highlights the design methodology, the prototype development and the ex-vivo testing of a sensing laparoscopic probe that could be used by surgeons and by surgeon’s assistive robotic systems for detection of small endoluminal digestive tumours. The proposed design framework guides the decision-makers towards a superior balance between quality, efficiency and surgical procedure issues in medical instruments development. A prototype of the sensitive laparoscopic probe for non-invasive intraoperative detection of small endoluminal digestive tumours was developed. The prototype was tested in ex-vivo experimental conditions – open and laparoscopic surgery. The results reveals that the developed prototype is easy to use, adequate and efficient in precise detection of small endoluminal digestive tumours in-between 60÷85% of cases.

  1. Basic principles of thermo-acoustic energy and temporal profile detection of microwave pulses

    CERN Document Server

    Andreev, V G; Vdovin, V A

    2001-01-01

    Basic principles of a thermo-acoustic method developed for the detection of powerful microwave pulses of nanosecond duration are discussed.A proposed method is based on the registration of acoustic pulse profile originated from the thermal expansion of the volume where microwave energy was absorbed.The amplitude of excited acoustic transient is proportional to absorbed microwave energy and its temporal profile resembles one of a microwave pulse when certain conditions are satisfied.The optimal regimes of microwave pulse energy detection and sensitivity of acoustic transient registration with piezo-transducer are discussed.It was demonstrated that profile of a microwave pulse could be detected with temporal resolution of 1 - 3 nanosecond.

  2. Theoretical detection threshold of the proton-acoustic range verification technique

    International Nuclear Information System (INIS)

    Ahmad, Moiz; Yousefi, Siavash; Xing, Lei; Xiang, Liangzhong

    2015-01-01

    Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10 6 per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range

  3. Theoretical detection threshold of the proton-acoustic range verification technique

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Moiz; Yousefi, Siavash; Xing, Lei, E-mail: lei@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847 (United States); Xiang, Liangzhong [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019-1101 (United States)

    2015-10-15

    Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10{sup 6} per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic

  4. Acoustic detection of UHE neutrinos in the Mediterranean sea: status and perspective

    Directory of Open Access Journals (Sweden)

    Simeone Francesco

    2017-01-01

    Full Text Available In recent years the astro-particle community is involved in the realization of experimental apparatuses for the detection of high energy neutrinos originated in cosmic sources or produced in the interaction of Cosmic Rays with the Cosmic Microwave Background. For neutrino energies in the TeV-PeV range, optical Cherenkov detectors, that have been so far positively exploited by Baikal[1], IceCube[2] and ANTARES[3], are considered optimal. For higher energies, three different experimental techniques are under study: the detection of radio pulses produced by showers induced by a neutrino interaction, the detection of air showers initiated by neutrinos interacting with rocks or deep Earth’s atmosphere and the detection of acoustic waves produced by deposition of energy following the interaction of neutrinos in an acoustically transparent medium. The potential of the acoustic detection technique, first proposed by Askaryan[4], to build very large neutrino detectors is appealing, thanks to the optimal properties of media such as water or ice as sound propagator. Though the studies on this technique are still in an early stage, acoustic positioning systems used to locate the optical modules in underwater Cherenkov neutrino detectors, give the possibility to study the ambient noise and provide important information for the future analysis of acoustic data.

  5. Active acoustic leak detection in steam generator units of fast reactors

    International Nuclear Information System (INIS)

    Oriol, L.; Journeau, Ch.

    1996-01-01

    Steam generators (SG) of Fast Reactors can be subject to water leakage into the sodium secondary circuit, causing an exothermic chemical reaction with potential serious damage to plant. Within the framework of the European Fast Reactor project, the CEA has developed an active acoustic detection technique which, when used in parallel with passive acoustic detection, will lead to effective leak detection results in terms of reliability and false alarm rates. Whilst the passive method is based on the increase in acoustic noise generated by the reaction, the active method takes advantage of the acoustic attenuation by the hydrogen bubbles produced. The method has been validated: in water, during laboratory testing at the Centre d'Etudes de Cadarache; in sodium, at the ASB loop at Bensberg (Germany) and at AEA Dounreay (Scotland). Full analysis of the tests carried out on the SG of the Prototype Fast Reactor in 1994 during end-of-life testing should lead to reactor validation on the method. (authors)

  6. Device for acoustic detection in a nuclear reactor

    International Nuclear Information System (INIS)

    Hanff, M.; Lions, N.; Peronnet, J.

    1975-01-01

    A description is given of a device which comprises a first acoustic conductor placed vertically within the coolant liquid contained in a nuclear reactor vessel and a second coaxial acoustic conductor extending to the exterior of the reactor vessel. The device essentially comprises an accelerometer assembly for detecting signals delivered by the second conductor and an amplifier which applies the detected signals to measuring instruments located outside the reactor vessel. The accelerometer comprises an amplifying pressure needle carried by the upper end of the second conductor, a piezoelectric ceramic element, a block fitted with a spring for applying the ceramic element against the needle and a preamplifier connected in series with the amplifier

  7. Sodium boiling detection in LMFBRs by acoustic-neutronic cross correlation

    International Nuclear Information System (INIS)

    Wright, S.A.

    1977-01-01

    The acoustic and neutronic noise signals caused by boiling are the signals primarily considered likely to detect sodium boiling in an LMFBR. Unfortunately, these signals may have serious signal-to-noise problems due to strong background noise sources. Neutronic-acoustic cross correlation techniques are expected to provide a means of improving the signal-to-noise ratio. This technique can improve the signal-to-noise ratio because the neutronic and acoustic signals due to boiling are highly correlated near the bubble repetition frequency, while the background noise sources are expected to be uncorrelated (or at most weakly correlated). An experiment was designed to show that the neutronic and acoustic noise signals are indeed highly correlated. The experiment consisted of simulating the void and pressure effects of local sodium boiling in the core of a zero-power reactor (ARK). The analysis showed that the neutronic and acoustic noise signals caused by boiling are almost perfectly correlated in a wide frequency band about the bubble repetition frequency. The results of the experiments were generalized to full-scale reactors to compare the inherent effectiveness of the methods which use the neutronic or acoustic signals alone with a hybrid method, which cross correlates the neutronic and acoustic signals. It was concluded that over a zone of the reactor where the void coefficient is sufficiently large (approximately 85 percent the core volume), the cross correlation method can provide a more rapid detection system for a given signal-to-noise ratio. However, where the void coefficient is small, one must probably rely on the acoustic method alone

  8. Acoustic detectability of Rhynchophorus cruentatus (Coleoptera: Dryophthoridae)

    Science.gov (United States)

    The palmetto weevil, Rhynchophorus cruentatus Fabricius, native to Florida, attacks palm trees. Like its economically destructive relatives, R. ferrugineus (Olivier) and R. palmarum L., it feeds internally and often is not detected until irreparable damage occurs. Acoustic methods previously used su...

  9. Bilateral acoustic neuromas.

    Science.gov (United States)

    Anand, V T; Byrnes, D P; Walby, A P; Kerr, A G

    1993-10-01

    This article reviews 12 patients with bilateral acoustic neuromas. The sex incidence was equal and the mean age at diagnosis was 26.2 years. The family history was positive in nine of the patients. Five patients have had incomplete surgical removal of acoustic neuromas on both sides. Two of them are completely deaf and the other three have severe sensorineural hearing loss in one ear and no hearing in the other ear. In five patients the tumour on one side has been operated on and the other side is being observed with at least short-term preservation of good hearing. The remaining two patients died of intra-cranial complications, one of them post-operatively. Four patients developed facial palsy immediately following surgery and one developed facial weakness 6 months after surgery. Guidelines are discussed for the care of these patients including the timing of surgery and alternative treatment options (observation, radio-surgery and chemotherapy). This is essentially a group of young individuals who have had multiple operations for bilateral acoustic tumours and associated manifestations and for whom the disease and the sequelae of treatment can be tragic.

  10. Intraoperative probe detecting β{sup −} decays in brain tumour radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Solfaroli Camillocci, E., E-mail: elena.solfaroli@roma1.infn.it [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Bocci, V.; Chiodi, G. [INFN Sezione di Roma, Roma (Italy); Collamati, F. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Donnarumma, R.; Faccini, R.; Mancini Terracciano, C. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Marafini, M. [INFN Sezione di Roma, Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche ‘E. Fermi’, Roma (Italy); Mattei, I.; Muraro, S. [Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Recchia, L. [INFN Sezione di Roma, Roma (Italy); Rucinski, A. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Russomando, A. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Toppi, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Traini, G. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Morganti, S. [INFN Sezione di Roma, Roma (Italy)

    2017-02-11

    Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β{sup −} emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β{sup −} emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on “ex vivo” specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.

  11. Total {sup 18}F-dopa PET tumour uptake reflects metabolic endocrine tumour activity in patients with a carcinoid tumour

    Energy Technology Data Exchange (ETDEWEB)

    Fiebrich, Helle-Brit; Walenkamp, Annemiek M.; Vries, Elisabeth G.E. de [University Medical Centre Groningen, Department of Medical Oncology, Groningen (Netherlands); Jong, Johan R. de; Koopmans, Klaas Pieter; Dierckx, Rudi A.J.O.; Brouwers, Adrienne H. [University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Kema, Ido P. [University Medical Centre Groningen, Department of Laboratory Medicine, Groningen (Netherlands); Sluiter, Wim; Links, Thera P. [University Medical Centre Groningen, Department of Endocrinology, Groningen (Netherlands)

    2011-10-15

    Positron emission tomography (PET) using 6-[{sup 18}F]fluoro-L-dihydroxyphenylalanine ({sup 18}F-dopa) has an excellent sensitivity to detect carcinoid tumour lesions. {sup 18}F-dopa tumour uptake and the levels of biochemical tumour markers are mediated by tumour endocrine metabolic activity. We evaluated whether total {sup 18}F-dopa tumour uptake on PET, defined as whole-body metabolic tumour burden (WBMTB), reflects tumour load per patient, as measured with tumour markers. Seventy-seven consecutive carcinoid patients who underwent an {sup 18}F-dopa PET scan in two previously published studies were analysed. For all tumour lesions mean standardised uptake values (SUVs) at 40% of the maximal SUV and tumour volume on {sup 18}F-dopa PET were determined and multiplied to calculate a metabolic burden per lesion. WBMTB was the sum of the metabolic burden of all individual lesions per patient. The 24-h urinary serotonin, urine and plasma 5-hydroxindoleacetic acid (5-HIAA), catecholamines (nor)epinephrine, dopamine and their metabolites, measured in urine and plasma, and serum chromogranin A served as tumour markers. All but 1 were evaluable for WBMTB; 74 patients had metastatic disease. {sup 18}F-dopa PET detected 979 lesions. SUV{sub max} on {sup 18}F-dopa PET varied up to 29-fold between individual lesions within the same patients. WBMTB correlated with urinary serotonin (r = 0.51) and urinary and plasma 5-HIAA (r = 0.78 and 0.66). WBMTB also correlated with urinary norepinephrine, epinephrine, dopamine and plasma dopamine, but not with serum chromogranin A. Tumour load per patient measured with {sup 18}F-dopa PET correlates with tumour markers of the serotonin and catecholamine pathway in urine and plasma in carcinoid patients, reflecting metabolic tumour activity. (orig.)

  12. Preliminary Study of Feasibility of Acoustic Detection of Small Sodium-Water Reactions in Lmfbr Steam Generators.

    Energy Technology Data Exchange (ETDEWEB)

    Chamberlain, H. V.

    1970-06-01

    An evaluation of acoustic techniques for the detection of sound resulting from water leaks into liquid sodium was conducted. Acoustic spectra over the range of 100Hz to 80kHz were detected. A leak as small as 0.00008 lb/ sec was detected by the acoustic instrumentation. The indicated leak rate was the smallest that was injected into the liquid sodium, and is not to be interpreted as the smallest leak rate that might be detected by the acoustic method. Detection time was found to be essentially instantaneous.

  13. Acoustic valve leak detection in nuclear plants

    International Nuclear Information System (INIS)

    Dimmick, J.G.; Dickey, J.W.

    1983-01-01

    Internal valve leakage is a hidden energy loss and can cause or prolong a forced outage. Recent advances in acoustic detection of internal valve leakage have reduced piping system maintenance costs, unnecessary downtime, and energy waste. Extremely short payback periods have been reported by plants applying this technology to preventive maintenance, troubleshooting, energy conservation and outage planning. Sensors temporarily attached to the outside of valves and connected to the instruments detect ultrasonic acoustic emissions which are characteristic of internal valve leakage. Since the sensors are attached to the outside of the valves, the time and expense of dismantling the valves or removing them from the systems are eliminated. This paper describes the instrumentation and specific applications to nuclear plant valves, including independent verification of initial findings. Guidelines for potential users, including instrumentation selection, training requirements, application planning, and the choice of in-house versus contract services are discussed

  14. Real-time RT-PCR systems for CTC detection from blood samples of breast cancer and gynaecological tumour patients (Review).

    Science.gov (United States)

    Andergassen, Ulrich; Kölbl, Alexandra C; Mahner, Sven; Jeschke, Udo

    2016-04-01

    Cells, which detach from a primary epithelial tumour and migrate through lymphatic vessels and blood stream are called 'circulating tumour cells'. These cells are considered to be the main root of remote metastasis and are correlated to a worse prognosis concerning progression-free and overall survival of the patients. Therefore, the detection of the minimal residual disease is of great importance regarding therapeutic decisions. Many different detection strategies are already available, but only one method, the CellSearch® system, reached FDA approval. The present review focusses on the detection of circulating tumour cells by means of real-time PCR, a highly sensitive method based on differences in gene expression between normal and malignant cells. Strategies for an enrichment of tumour cells are mentioned, as well as a large panel of potential marker genes. Drawbacks and advantages of the technique are elucidated, whereas, the greatest advantage might be, that by selection of appropriate marker genes, also tumour cells, which have already undergone epithelial to mesenchymal transition can be detected. Finally, the application of real-time PCR in different gynaecological malignancies is described, with breast cancer being the most studied cancer entity.

  15. Tadarida: A Toolbox for Animal Detection on Acoustic Recordings

    Directory of Open Access Journals (Sweden)

    Yves Bas

    2017-02-01

    Full Text Available Passive Acoustic Monitoring (PAM recently extended to a very wide range of animals, but no available open software has been sufficiently generic to automatically treat several taxonomic groups. Here we present Tadarida, a software toolbox allowing for the detection and labelling of recorded sound events, and to classify any new acoustic data into known classes. It is made up of three modules handling Detection, Labelling and Classification and running on either Linux or Windows. This development resulted in the first open software (1 allowing generic sound event detection (multi-taxa, (2 providing graphical sound labelling at a single-instance level and (3 covering the whole process from sound detection to classification. This generic and modular design opens numerous reuse opportunities among (bioacoustics researchers, especially for those managing and/or developing PAM schemes. The whole toolbox is openly developed in C++ (Detection and Labelling and R (Classification and stored at https://github.com/YvesBas.

  16. Acoustic Emission Beamforming for Detection and Localization of Damage

    Science.gov (United States)

    Rivey, Joshua Callen

    The aerospace industry is a constantly evolving field with corporate manufacturers continually utilizing innovative processes and materials. These materials include advanced metallics and composite systems. The exploration and implementation of new materials and structures has prompted the development of numerous structural health monitoring and nondestructive evaluation techniques for quality assurance purposes and pre- and in-service damage detection. Exploitation of acoustic emission sensors coupled with a beamforming technique provides the potential for creating an effective non-contact and non-invasive monitoring capability for assessing structural integrity. This investigation used an acoustic emission detection device that employs helical arrays of MEMS-based microphones around a high-definition optical camera to provide real-time non-contact monitoring of inspection specimens during testing. The study assessed the feasibility of the sound camera for use in structural health monitoring of composite specimens during tensile testing for detecting onset of damage in addition to nondestructive evaluation of aluminum inspection plates for visualizing stress wave propagation in structures. During composite material monitoring, the sound camera was able to accurately identify the onset and location of damage resulting from large amplitude acoustic feedback mechanisms such as fiber breakage. Damage resulting from smaller acoustic feedback events such as matrix failure was detected but not localized to the degree of accuracy of larger feedback events. Findings suggest that beamforming technology can provide effective non-contact and non-invasive inspection of composite materials, characterizing the onset and the location of damage in an efficient manner. With regards to the nondestructive evaluation of metallic plates, this remote sensing system allows us to record wave propagation events in situ via a single-shot measurement. This is a significant improvement over

  17. The availability of the detection method of internal valve leakage using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Suzuki, Akio

    1989-01-01

    The purpose of this study is to estimate the availability of acoustic method to the internal leakage of the valves at power plants. The acoustic method was applied to the valves at the site, and the background noise was measured for the abnormal plantcondition. From the comparison of the background noise date with the experimental results as to relation between leakage flow and acoust signal, the minimum leakage flow rates that can be detected by the acoust signal was suggested. When the background levels are higher than the acoust signal, the method described below was considered that the analysis the remainder among the background noise frequency spectrum and the acoustic signal spectrum become a very useful leak detection method. A few experimental examples of the spectrum analysis that varied the background noise characteristic were given. (author)

  18. Development of the On-line Acoustic Leak Detection Tool for the SFR Steam Generator Protection

    International Nuclear Information System (INIS)

    Kim, Tae-Joon; Jeong, Ji-Young; Kim, Jong-Man; Kim, Byung-Ho; Kim, Seong-O

    2007-01-01

    The successful detection of a water/steam into a sodium leak in the SFR SG (steam generator) at an early phase of a leak origin depends on the fast response and sensitivity of a leak detection system. This intention of an acoustic leak detection system is stipulated by a key impossibility of a fast detecting of an intermediate leak by the present nominal systems such as the hydrogen meter. Subject of this study is to introduce the detection performance of an on-line acoustic leak detection tool discriminated by a back-propagation neural network with a preprocessing of the 1/m Octave band analysis, and to introduce the status of an on-line development being developed with the acoustic leak detection tool(S/W) in KAERI. For a performance test, it was used with the acoustic signals for a sodium-water reaction from the injected steam into water experiments in KAERI, the acoustic signals injected from the water into the sodium obtained in IPPE, and the background noise of the PFR superheater

  19. Acoustical Detection Of Leakage In A Combustor

    Science.gov (United States)

    Puster, Richard L.; Petty, Jeffrey L.

    1993-01-01

    Abnormal combustion excites characteristic standing wave. Acoustical leak-detection system gives early warning of failure, enabling operating personnel to stop combustion process and repair spray bar before leak grows large enough to cause damage. Applicable to engines, gas turbines, furnaces, and other machines in which acoustic emissions at known frequencies signify onset of damage. Bearings in rotating machines monitored for emergence of characteristic frequencies shown in previous tests associated with incipient failure. Also possible to monitor for signs of trouble at multiple frequencies by feeding output of transducer simultaneously to multiple band-pass filters and associated circuitry, including separate trigger circuit set to appropriate level for each frequency.

  20. Investigation of acoustic sensors to detect coconut rhinoceros beetle in Guam

    Science.gov (United States)

    The coconut rhinoceros beetle, Oryctes rhinoceros, was accidentally introduced into Guam last year and now threatens the Island’s forests and tourist industry. These large insects can be detected easily with acoustic sensors, and procedures are being developed to incorporate acoustic technology int...

  1. Robotic vehicle uses acoustic sensors for voice detection and diagnostics

    Science.gov (United States)

    Young, Stuart H.; Scanlon, Michael V.

    2000-07-01

    An acoustic sensor array that cues an imaging system on a small tele- operated robotic vehicle was used to detect human voice and activity inside a building. The advantage of acoustic sensors is that it is a non-line of sight (NLOS) sensing technology that can augment traditional LOS sensors such as visible and IR cameras. Acoustic energy emitted from a target, such as from a person, weapon, or radio, will travel through walls and smoke, around corners, and down corridors, whereas these obstructions would cripple an imaging detection system. The hardware developed and tested used an array of eight microphones to detect the loudest direction and automatically setter a camera's pan/tilt toward the noise centroid. This type of system has applicability for counter sniper applications, building clearing, and search/rescue. Data presented will be time-frequency representations showing voice detected within rooms and down hallways at various ranges. Another benefit of acoustics is that it provides the tele-operator some situational awareness clues via low-bandwidth transmission of raw audio data for the operator to interpret with either headphones or through time-frequency analysis. This data can be useful to recognize familiar sounds that might indicate the presence of personnel, such as talking, equipment, movement noise, etc. The same array also detects the sounds of the robot it is mounted on, and can be useful for engine diagnostics and trouble shooting, or for self-noise emanations for stealthy travel. Data presented will characterize vehicle self noise over various surfaces such as tiles, carpets, pavement, sidewalk, and grass. Vehicle diagnostic sounds will indicate a slipping clutch and repeated unexpected application of emergency braking mechanism.

  2. Circulating tumour cells escape from EpCAM-based detection due to epithelial-to-mesenchymal transition

    International Nuclear Information System (INIS)

    Gorges, Tobias M; Tinhofer, Ingeborg; Drosch, Michael; Röse, Lars; Zollner, Thomas M; Krahn, Thomas

    2012-01-01

    Circulating tumour cells (CTCs) have shown prognostic relevance in metastatic breast, prostate, colon and pancreatic cancer. For further development of CTCs as a biomarker, we compared the performance of different protocols for CTC detection in murine breast cancer xenograft models (MDA-MB-231, MDA-MB-468 and KPL-4). Blood samples were taken from tumour bearing animals (20 to 200 mm 2 ) and analysed for CTCs using 1. an epithelial marker based enrichment method (AdnaTest), 2. an antibody independent technique, targeting human gene transcripts (qualitative PCR), and 3. an antibody-independent approach, targeting human DNA-sequences (quantitative PCR). Further, gene expression changes associated with epithelial-to-mesenchymal transition (EMT) were determined with an EMT-specific PCR assay. We used the commercially available Adna Test, RT-PCR on human housekeeping genes and a PCR on AluJ sequences to detect CTCs in xenografts models. Phenotypic changes in CTCs were tested with the commercially available “Human Epithelial to Mesenchymal Transition RT-Profiler PCR Array”. Although the AdnaTest detects as few as 1 tumour cell in 1 ml of mouse blood spiking experiments, no CTCs were detectable with this approach in vivo despite visible metastasis formation. The presence of CTCs could, however, be demonstrated by PCR targeting human transcripts or DNA-sequences - without epithelial pre-enrichment. The failure of CTC detection by the AdnaTest resulted from downregulation of EpCAM, whereas mesenchymal markers like Twist and EGFR were upregulated on CTCs. Such a change in the expression profile during metastatic spread of tumour cells has already been reported and was linked to a biological program termed epithelial-mesenchymal transition (EMT). The use of EpCAM-based enrichment techniques leads to the failure to detect CTC populations that have undergone EMT. Our findings may explain clinical results where low CTC numbers have been reported even in patients with late

  3. Assessment of quantitative FDG PET data in primary colorectal tumours: which parameters are important with respect to tumour detection?

    International Nuclear Information System (INIS)

    Strauss, Ludwig G.; Pan, Leyun; Dimitrakopoulou-Strauss, Antonia; Klippel, Sven; Schoenleben, Klaus; Haberkorn, Uwe

    2007-01-01

    The impact of quantitative parameters on the differentiation of primary colorectal tumours from normal colon tissue was assessed. Dynamic PET data (DPET) were acquired, and compartment and non-compartment modelling applied. The discriminant power of single parameters and the combination of PET parameters was assessed. All lesions were confirmed by histology. FDG DPET studies were acquired in 22 patients with colorectal tumours prior to surgery. Five of these patients also had liver metastases at the time of the PET study. The SUV 56-60 min p.i. was included in the evaluation. A two-tissue compartment model was applied and the parameters k 1 -k 4 as well as the fractional blood volume (V B ) were obtained. The FDG influx was calculated from the compartment data. Non-compartment modelling was used to calculate the fractal dimension (FD) of the time-activity data. FD, SUV, influx and k 3 were the most important single parameters for lesion differentiation. The highest accuracy was achieved for FD (88.78%). The overall tracer uptake was mainly dependent on k 3 and not on k 1 or V B . The support vector machines (SVM) algorithm was used to predict the classification based on the combination of individual PET parameters. The overall accuracy was 97.3%, with only one false positive case and no false negative results. The analysis of the subgroup of five patients with primary tumours and synchronous metastases revealed no significant differences for the individual PET parameters. However, V B tended to be lower while k 1 and k 2 were higher in patients with synchronous metastases. The SVM classification analysis predicted the presence of metastases based on the PET data of the primary tumour in three of five patients. Quantitative FDG PET studies provide very accurate data for the differentiation of primary colorectal tumours from normal tissue. The use of quantitative data has the advantage that the detection of a colorectal tumour is not primarily dependent on the

  4. On-chip integrated labelling, transport and detection of tumour cells.

    Science.gov (United States)

    Woods, Jane; Docker, Peter T; Dyer, Charlotte E; Haswell, Stephen J; Greenman, John

    2011-11-01

    Microflow cytometry represents a promising tool for the investigation of diagnostic and prognostic cellular cancer markers, particularly if integrated within a device that allows primary cells to be freshly isolated from the solid tumour biopsies that more accurately reflect patient-specific in vivo tissue microenvironments at the time of staining. However, current tissue processing techniques involve several sequential stages with concomitant cell losses, and as such are inappropriate for use with small biopsies. Accordingly, we present a simple method for combined antibody-labelling and dissociation of heterogeneous cells from a tumour mass, which reduces the number of processing steps. Perfusion of ex vivo tissue at 4°C with antibodies and enzymes slows cellular activity while allowing sufficient time for the diffusion of minimally active enzymes. In situ antibody-labelled cells are then dissociated at 37°C from the tumour mass, whereupon hydrogel-filled channels allow the release of relatively low cell numbers (<1000) into a biomimetic microenvironment. This novel approach to sample processing is then further integrated with hydrogel-based electrokinetic transport of the freshly liberated fluorescent cells for downstream detection. It is anticipated that this integrated microfluidic methodology will have wide-ranging biomedical and clinical applications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. On the Detectability of Acoustic Waves Induced Following Irradiation by a Radiotherapy Linear Accelerator.

    Science.gov (United States)

    Hickling, Susannah; Leger, Pierre; El Naqa, Issam

    2016-02-11

    Irradiating an object with a megavoltage photon beam generated by a clinical radiotherapy linear accelerator (linac) induces acoustic waves through the photoacoustic effect. The detection and characterization of such acoustic waves has potential applications in radiation therapy dosimetry. The purpose of this work was to gain insight into the properties of such acoustic waves by simulating and experimentally detecting them in a well-defined system consisting of a metal block suspended in a water tank. A novel simulation workflow was developed by combining radiotherapy Monte Carlo and acoustic wave transport simulation techniques. Different set-up parameters such as photon beam energy, metal block depth, metal block width, and metal block material were varied, and the simulated and experimental acoustic waveforms showed the same relative amplitude trends and frequency variations for such setup changes. The simulation platform developed in this work can easily be extended to other irradiation situations, and will be an invaluable tool for developing a radiotherapy dosimetry system based on the detection of the acoustic waves induced following linear accelerator irradiation.

  6. Acoustic detection of ultra-high energy cascades in ice

    Energy Technology Data Exchange (ETDEWEB)

    Boeser, S.

    2006-12-08

    Current underwater optical neutrino telescopes are designed to detect neutrinos from astrophysical sources with energies in the TeV range. Due to the low fluxes and small cross sections, no high energy neutrinos of extraterrestrial origin have been observed so far. Only the Cherenkov neutrino detectors on the km{sup 3} scale that are currently under construction will have the necessary volume to observe these rare interactions. For the guaranteed source of neutrinos from interactions of the ultra-high energy cosmic at EeV energies rays with the ambient cosmic microwave background, event rates of only one per year are expected in these experiments. To measure the flux and verify the predicted cross sections of these cosmogenic neutrinos, an observed volume of the order of 100 km{sup 3} will be necessary, that will not be feasible with existing detection techniques. Alternative methods are required to build a detector on these scales. One promising idea is to record the acoustic waves generated in hadronic or electromagnetic cascades following the neutrino interaction. The higher amplitudes of the sonic signal and the large expected absorption length of sound favour South Polar ice instead of sea water as a medium. The prerequisites for an estimate of the potential of such a detector are suitable acoustic sensors, a verification of the model of thermo-acoustic sound generation and a determination of the acoustic properties of the ice. In a theoretical derivation the mechanism of thermo-elastic excitation of acoustic waves was shown to be equivalent for isotropic solids and liquids. Following a detailed analysis of the existing knowledge a simulation study of a hybrid optical-radio-acoustic detector has been performed. Ultrasonic sensors dedicated to in-ice application were developed and have been used to record acoustic signals from intense proton and laser beams in water and ice. With the obtained experience, the hitherto largest array of acoustic sensors and

  7. Acoustic detection of ultra-high energy cascades in ice

    International Nuclear Information System (INIS)

    Boeser, S.

    2006-01-01

    Current underwater optical neutrino telescopes are designed to detect neutrinos from astrophysical sources with energies in the TeV range. Due to the low fluxes and small cross sections, no high energy neutrinos of extraterrestrial origin have been observed so far. Only the Cherenkov neutrino detectors on the km 3 scale that are currently under construction will have the necessary volume to observe these rare interactions. For the guaranteed source of neutrinos from interactions of the ultra-high energy cosmic at EeV energies rays with the ambient cosmic microwave background, event rates of only one per year are expected in these experiments. To measure the flux and verify the predicted cross sections of these cosmogenic neutrinos, an observed volume of the order of 100 km 3 will be necessary, that will not be feasible with existing detection techniques. Alternative methods are required to build a detector on these scales. One promising idea is to record the acoustic waves generated in hadronic or electromagnetic cascades following the neutrino interaction. The higher amplitudes of the sonic signal and the large expected absorption length of sound favour South Polar ice instead of sea water as a medium. The prerequisites for an estimate of the potential of such a detector are suitable acoustic sensors, a verification of the model of thermo-acoustic sound generation and a determination of the acoustic properties of the ice. In a theoretical derivation the mechanism of thermo-elastic excitation of acoustic waves was shown to be equivalent for isotropic solids and liquids. Following a detailed analysis of the existing knowledge a simulation study of a hybrid optical-radio-acoustic detector has been performed. Ultrasonic sensors dedicated to in-ice application were developed and have been used to record acoustic signals from intense proton and laser beams in water and ice. With the obtained experience, the hitherto largest array of acoustic sensors and transmitters was

  8. Factors Affecting Detection Probability of Acoustic Tags in Coral Reefs

    KAUST Repository

    Bermudez, Edgar F.

    2012-05-01

    Acoustic telemetry is an important tool for studying the movement patterns, behaviour, and site fidelity of marine organisms; however, its application is challenged in coral reef environments where complex topography and intense environmental noise interferes with acoustic signals, and there has been less study. Therefore, it is particularly critical in coral reef telemetry studies to first conduct a long-term range test, a tool that provides informa- tion on the variability and periodicity of the transmitter detection range and the detection probability. A one-month range test of a coded telemetric system was conducted prior to a large-scale tagging project investigating the movement of approximately 400 fishes from 30 species on offshore coral reefs in the central Red Sea. During this range test we determined the effect of the following factors on transmitter detection efficiency: distance from receiver, time of day, depth, wind, current, moon-phase and temperature. The experiment showed that biological noise is likely to be responsible for a diel pattern of -on average- twice as many detections during the day as during the night. Biological noise appears to be the most important noise source in coral reefs overwhelming the effect of wind-driven noise, which is important in other studies. Detection probability is also heavily influenced by the location of the acoustic sensor within the reef structure. Understanding the effect of environmental factors on transmitter detection probability allowed us to design a more effective receiver array for the large-scale tagging study.

  9. Imaging and detection of mines from acoustic measurements

    Science.gov (United States)

    Witten, Alan J.; DiMarzio, Charles A.; Li, Wen; McKnight, Stephen W.

    1999-08-01

    A laboratory-scale acoustic experiment is described where a buried target, a hockey puck cut in half, is shallowly buried in a sand box. To avoid the need for source and receiver coupling to the host sand, an acoustic wave is generated in the subsurface by a pulsed laser suspended above the air-sand interface. Similarly, an airborne microphone is suspended above this interface and moved in unison with the laser. After some pre-processing of the data, reflections for the target, although weak, could clearly be identified. While the existence and location of the target can be determined by inspection of the data, its unique shape can not. Since target discrimination is important in mine detection, a 3D imaging algorithm was applied to the acquired acoustic data. This algorithm yielded a reconstructed image where the shape of the target was resolved.

  10. ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-10-31

    The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

  11. ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-12-01

    The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

  12. All-optical in-depth detection of the acoustic wave emitted by a single gold nanorod

    Science.gov (United States)

    Xu, Feng; Guillet, Yannick; Ravaine, Serge; Audoin, Bertrand

    2018-04-01

    A single gold nanorod dropped on the surface of a silica substrate is used as a transient optoacoustic source of gigahertz hypersounds. We demonstrate the all-optical detection of the as-generated acoustic wave front propagating in the silica substrate. For this purpose, time-resolved femtosecond pump-probe experiments are performed in a reflection configuration. The fundamental breathing mode of the nanorod is detected at 23 GHz by interferometry, and the longitudinal acoustic wave radiated in the silica substrate is detected by time-resolved Brillouin scattering. By tuning the optical probe wavelength from 750 to 900 nm, hypersounds with wavelengths of 260-315 nm are detected in the silica substrate, with corresponding acoustic frequencies in the range of 19-23 GHz. To confirm the origin of these hypersounds, we theoretically analyze the influence of the acoustic excitation spectrum on the temporal envelope of the transient reflectivity. This analysis proves that the acoustic wave detected in the silica substrate results from the excitation of the breathing mode of the nanorod. These results pave the way for performing local in-depth elastic nanoscopy.

  13. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    International Nuclear Information System (INIS)

    Marchevsky, M; Wang, X; Sabbi, G; Prestemon, S

    2013-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb3Sn quadrupole HQ01, we show how acoustic data is connected with voltage instabilities measured simultaneously in the magnet windings during provoked extractions and current ramps to quench. Instrumentation and data analysis techniques for acoustic sensing are reviewed. (author)

  14. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    CERN Document Server

    Marchevsky, M.; Sabbi, G.; Prestemon, S.

    2013-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb$_{3}$Sn quadrupole HQ01 [1], we show how acoustic data is connected with voltage instabilities measured simultaneously in the magnet windings during provoked extractions and current ramps to quench. Instrumentation and data analysis techniques for acoustic sensing are reviewed.

  15. Acoustic detection for water/steam leak from a tube of LMFBR steam generator

    International Nuclear Information System (INIS)

    Sonoda, Masataka; Shindo, Yoshihisa

    1989-01-01

    Acoustic leak detector is useful for detecting more quickly intermediate leak than the existing hydrogen detector and is available for identification of leak location on the accident of water/steam leak from a tube of LMFBR steam generator. This paper presents the overview of HALD (High frequency Acoustics Leak Detection) system, which is more sensitive for leak detection and lower cost of equipment for identification of leak location than a low frequency type detector. (author)

  16. Topography and biological noise determine acoustic detectability on coral reefs

    KAUST Repository

    Cagua, Edgar F.

    2013-08-19

    Acoustic telemetry is an increasingly common tool for studying the movement patterns, behavior and site fidelity of marine organisms, but to accurately interpret acoustic data, the variability, periodicity and range of detectability between acoustic tags and receivers must be understood. The relative and interactive effects of topography with biological and environmental noise have not been quantified on coral reefs. We conduct two long-term range tests (1- and 4-month duration) on two different reef types in the central Red Sea to determine the relative effect of distance, depth, topography, time of day, wind, lunar phase, sea surface temperature and thermocline on detection probability. Detectability, as expected, declines with increasing distance between tags and receivers, and we find average detection ranges of 530 and 120 m, using V16 and V13 tags, respectively, but the topography of the reef can significantly modify this relationship, reducing the range by ~70 %, even when tags and receivers are in line-of-sight. Analyses that assume a relationship between distance and detections must therefore be used with care. Nighttime detection range was consistently reduced in both locations, and detections varied by lunar phase in the 4-month test, suggesting a strong influence of biological noise (reducing detection probability up to 30 %), notably more influential than other environmental noises, including wind-driven noise, which is normally considered important in open-water environments. Analysis of detections should be corrected in consideration of the diel patterns we find, and range tests or sentinel tags should be used for more than 1 month to quantify potential changes due to lunar phase. Some studies assume that the most usual factor limiting detection range is weather-related noise; this cannot be extrapolated to coral reefs. © 2013 Springer-Verlag Berlin Heidelberg.

  17. Detection of ductile crack initiation by acoustic emission testing

    International Nuclear Information System (INIS)

    Richter, H.; Boehmert, J.; Viehrig, H.W.

    1998-08-01

    A Charpy impact test equipment is described permitting simultaneous measurement of impact force, crack tip opening, acoustic emissions and magnetic emissions. The core of the equipment is an inverted pendulum ram impact testing machine and the tests have been performed with laterally notched, pre-fatigue ISO-V specimens made of steels of various strength and toughness properties. The tests are intended to ascertain whether the acoustic emission method is suitable for detecting steady crack initiation in highly ductile steels. (orig./CB) [de

  18. The current status of research and development concerning steam generator acoustic leak detection for the demonstration FBR plant

    International Nuclear Information System (INIS)

    Higuchi, Masahisa

    1990-01-01

    The Japan Atomic Power Co. (JAPC) started the research and development into Acoustic Leak Detection for the Demonstration FBR (D-FBR) plant in 1989. Acoustic Leak Detection is expected as a water leak detection system in the Steam Generator for the first D-FBR plant. JAPC is presently analyzing data on Acoustic Leak Detection in order to form some basic concepts and basic specifications about leak detection. Both low frequency types and high frequency types are selected as candidates for Acoustic Leak Detection. After a review of both types, either one will be selected for the D-FBT plant. A detailed Research and Development plan on Acoustic Leak Detection, which should be carried out prior to starting the construction of the D-FBR plant, is under review. (author). 3 figs, 2 tabs

  19. In-vivo detection of the erythropoietin receptor in tumours using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fuge, Felix; Doleschel, Dennis; Rix, Anne; Gremse, Felix; Lederle, Wiltrud; Kiessling, Fabian [RWTH Aachen University, Department for Experimental Molecular Imaging (ExMI), Medical Faculty, Aachen (Germany); Wessner, Axel [Roche Diagnostics GmbH, R and D RPD Protein Chemistry, Penzberg (Germany); Winz, Oliver; Mottaghy, Felix [University Clinic RWTH Aachen, Clinic for Nuclear Medicine, Aachen (Germany)

    2014-09-09

    Recombinant human erythropoietin (rhuEpo) is used clinically to treat anaemia. However, rhuEpo-treated cancer patients show decreased survival rates and erythropoietin receptor (EpoR) expression has been found in patient tumour tissue. Thus, rhuEpo application might promote EpoR{sup +} tumour progression. We therefore developed the positron emission tomography (PET)-probe {sup 68}Ga-DOTA-rhuEpo and evaluated its performance in EpoR{sup +} A549 non-small-cell lung cancer (NSCLC) xenografts. {sup 68}Ga-DOTA-rhuEpo was generated by coupling DOTA-hydrazide to carbohydrate side-chains of rhuEpo. Biodistribution was determined in tumour-bearing mice 0.5, 3, 6, and 9 h after probe injection. Competition experiments were performed by co-injecting {sup 68}Ga-DOTA-rhuEpo and rhuEpo in five-fold excess. Probe specificity was further evaluated histologically using Epo-Cy5.5 stainings. The blood half-life of {sup 68}Ga-DOTA-rhuEpo was 2.6 h and the unbound fraction was cleared by the liver and kidney. After 6 h, the highest tumour to muscle ratio was reached. The highest {sup 68}Ga-DOTA-rhuEpo accumulation was found in liver (10.06 ± 6.26%ID/ml), followed by bone marrow (1.87 ± 0.53%ID/ml), kidney (1.58 ± 0.39 %ID/ml), and tumour (0.99 ± 0.16%ID/ml). EpoR presence in these organs was histologically confirmed. Competition experiments showed significantly (p < 0.05) lower PET-signals in tumour and bone marrow at 3 and 6 h. {sup 68}Ga-DOTA-rhuEpo shows favourable pharmacokinetic properties and detects EpoR specifically. Therefore, it might become a valuable radiotracer to monitor EpoR status in tumours and support decision-making in anaemia therapy. (orig.)

  20. RELIABILITY OF THE DETECTION OF THE BARYON ACOUSTIC PEAK

    International Nuclear Information System (INIS)

    MartInez, Vicent J.; Arnalte-Mur, Pablo; De la Cruz, Pablo; Saar, Enn; Tempel, Elmo; Pons-BorderIa, MarIa Jesus; Paredes, Silvestre; Fernandez-Soto, Alberto

    2009-01-01

    The correlation function of the distribution of matter in the universe shows, at large scales, baryon acoustic oscillations, which were imprinted prior to recombination. This feature was first detected in the correlation function of the luminous red galaxies of the Sloan Digital Sky Survey (SDSS). Recently, the final release (DR7) of the SDSS has been made available, and the useful volume is about two times bigger than in the old sample. We present here, for the first time, the redshift-space correlation function of this sample at large scales together with that for one shallower, but denser volume-limited subsample drawn from the Two-Degree Field Redshift Survey. We test the reliability of the detection of the acoustic peak at about 100 h -1 Mpc and the behavior of the correlation function at larger scales by means of careful estimation of errors. We confirm the presence of the peak in the latest data although broader than in previous detections.

  1. Probability of acoustic transmitter detections by receiver lines in Lake Huron: results of multi-year field tests and simulations

    Science.gov (United States)

    Hayden, Todd A.; Holbrook, Christopher M.; Binder, Thomas; Dettmers, John M.; Cooke, Steven J.; Vandergoot, Christopher S.; Krueger, Charles C.

    2016-01-01

    BackgroundAdvances in acoustic telemetry technology have led to an improved understanding of the spatial ecology of many freshwater and marine fish species. Understanding the performance of acoustic receivers is necessary to distinguish between tagged fish that may have been present but not detected and from those fish that were absent from the area. In this study, two stationary acoustic transmitters were deployed 250 m apart within each of four acoustic receiver lines each containing at least 10 receivers (i.e., eight acoustic transmitters) located in Saginaw Bay and central Lake Huron for nearly 2 years to determine whether the probability of detecting an acoustic transmission varied as a function of time (i.e., season), location, and distance between acoustic transmitter and receiver. Distances between acoustic transmitters and receivers ranged from 200 m to >10 km in each line. The daily observed probability of detecting an acoustic transmission was used in simulation models to estimate the probability of detecting a moving acoustic transmitter on a line of receivers.ResultsThe probability of detecting an acoustic transmitter on a receiver 1000 m away differed by month for different receiver lines in Lake Huron and Saginaw Bay but was similar for paired acoustic transmitters deployed 250 m apart within the same line. Mean probability of detecting an acoustic transmitter at 1000 m calculated over the study period varied among acoustic transmitters 250 m apart within a line and differed among receiver lines in Lake Huron and Saginaw Bay. The simulated probability of detecting a moving acoustic transmitter on a receiver line was characterized by short periods of time with decreased detection. Although increased receiver spacing and higher fish movement rates decreased simulated detection probability, the location of the simulated receiver line in Lake Huron had the strongest effect on simulated detection probability.ConclusionsPerformance of receiver

  2. Circulating tumour cells escape from EpCAM-based detection due to epithelial-to-mesenchymal transition

    Directory of Open Access Journals (Sweden)

    Gorges Tobias M

    2012-05-01

    Full Text Available Abstract Background Circulating tumour cells (CTCs have shown prognostic relevance in metastatic breast, prostate, colon and pancreatic cancer. For further development of CTCs as a biomarker, we compared the performance of different protocols for CTC detection in murine breast cancer xenograft models (MDA-MB-231, MDA-MB-468 and KPL-4. Blood samples were taken from tumour bearing animals (20 to 200 mm2 and analysed for CTCs using 1. an epithelial marker based enrichment method (AdnaTest, 2. an antibody independent technique, targeting human gene transcripts (qualitative PCR, and 3. an antibody-independent approach, targeting human DNA-sequences (quantitative PCR. Further, gene expression changes associated with epithelial-to-mesenchymal transition (EMT were determined with an EMT-specific PCR assay. Methods We used the commercially available Adna Test, RT-PCR on human housekeeping genes and a PCR on AluJ sequences to detect CTCs in xenografts models. Phenotypic changes in CTCs were tested with the commercially available “Human Epithelial to Mesenchymal Transition RT-Profiler PCR Array”. Results Although the AdnaTest detects as few as 1 tumour cell in 1 ml of mouse blood spiking experiments, no CTCs were detectable with this approach in vivo despite visible metastasis formation. The presence of CTCs could, however, be demonstrated by PCR targeting human transcripts or DNA-sequences - without epithelial pre-enrichment. The failure of CTC detection by the AdnaTest resulted from downregulation of EpCAM, whereas mesenchymal markers like Twist and EGFR were upregulated on CTCs. Such a change in the expression profile during metastatic spread of tumour cells has already been reported and was linked to a biological program termed epithelial-mesenchymal transition (EMT. Conclusions The use of EpCAM-based enrichment techniques leads to the failure to detect CTC populations that have undergone EMT. Our findings may explain clinical results where low

  3. Acoustic detection of intracranial aneurysms : A decision analysis

    NARCIS (Netherlands)

    vanBruggen, AC; Dippel, DWJ; Habbema, JDF; Mooij, JJA

    1996-01-01

    We present a further evaluation of an improved recording method for the acoustic detection of intracranial aneurysms (ADA). A sensor was applied to the patient's eyes. Two measures were derived to summarize the power spectral density functions of the sound frequencies that were obtained from each

  4. Detection and Classification of Whale Acoustic Signals

    Science.gov (United States)

    Xian, Yin

    This dissertation focuses on two vital challenges in relation to whale acoustic signals: detection and classification. In detection, we evaluated the influence of the uncertain ocean environment on the spectrogram-based detector, and derived the likelihood ratio of the proposed Short Time Fourier Transform detector. Experimental results showed that the proposed detector outperforms detectors based on the spectrogram. The proposed detector is more sensitive to environmental changes because it includes phase information. In classification, our focus is on finding a robust and sparse representation of whale vocalizations. Because whale vocalizations can be modeled as polynomial phase signals, we can represent the whale calls by their polynomial phase coefficients. In this dissertation, we used the Weyl transform to capture chirp rate information, and used a two dimensional feature set to represent whale vocalizations globally. Experimental results showed that our Weyl feature set outperforms chirplet coefficients and MFCC (Mel Frequency Cepstral Coefficients) when applied to our collected data. Since whale vocalizations can be represented by polynomial phase coefficients, it is plausible that the signals lie on a manifold parameterized by these coefficients. We also studied the intrinsic structure of high dimensional whale data by exploiting its geometry. Experimental results showed that nonlinear mappings such as Laplacian Eigenmap and ISOMAP outperform linear mappings such as PCA and MDS, suggesting that the whale acoustic data is nonlinear. We also explored deep learning algorithms on whale acoustic data. We built each layer as convolutions with either a PCA filter bank (PCANet) or a DCT filter bank (DCTNet). With the DCT filter bank, each layer has different a time-frequency scale representation, and from this, one can extract different physical information. Experimental results showed that our PCANet and DCTNet achieve high classification rate on the whale

  5. Acoustic detection for small-leak sodium-water reaction

    International Nuclear Information System (INIS)

    Nei, Hiromichi; Ohshima, Iwao; Ujihara, Kozaburo; Hori, Masao

    1977-01-01

    Characteristics of acoustic signal produced by sodium-water reaction due to steam injection and by Ar gas injection into sodium were experimentally investigated. Acoustic signal was measured by using Kistler 808A and 815A5 accelerometers. Root mean square (RMS) measurements and frequency analysis of the signal were conducted. The RMS measurements could detect a small water leakage into sodium, as small as 0.07g/sec, in the present loop. The peaks in a frequency spectrum were caused by the natural vibration of a rod on which the acoustic transducer was mounted. The RMS was approximately proportional to the one-third power of the steam leak rate and increased to some extent with the ambient sodium temperature. RMS values, both for sodium-water reaction and Ar gas injection, were about the same order of magnitude, when the data were plotted against the volumetric flow rates of steam and Argas. (auth.)

  6. Detection of circulating tumour cells in peripheral blood of patients with malignant pleural mesothelioma.

    Science.gov (United States)

    Raphael, Jacques; Massard, Christophe; Gong, Inna Y; Farace, Françoise; Margery, Jacques; Billiot, Fanny; Hollebecque, Antoine; Besse, Benjamin; Soria, Jean-Charles; Planchard, David

    2015-01-01

    The independent prognostic value of Circulating Tumour Cells (CTC) level has been demonstrated in several solid tumours. There is currently few data on Malignant Pleural Mesothelioma (MPM) and CTC. We investigated whether the presence of CTC was correlated with prognosis factors and treatment efficacy. MPM patients (pts) were enrolled in a prospective monocentric study. CTC detection was made using the "CellSearch" assay. The correlation between the presence of CTC and worse prognosis factors was assessed using the X(2) test. Comparison of Overall Survival (OS) and Progression Free Survival (PFS) according to CTC detection was performed using the log-rank test. Twenty-seven MPM pts with a median follow-up of 4.2 months were included. CTC were detected in 44% of pts with a median level of 1.5. No significant correlation was observed between the presence of CTC and worse prognosis factors. Moreover, CTC detection was not a significant predictor of OS or PFS (p=0.155 and p=0.32 respectively). CTC were detected in a small cohort of MPM patients. We couldn't demonstrate a significant prognostic value or a difference in OS/PFS between CTC levels. Further analyses, validation studies and detection techniques are needed to establish their real clinical value in MPM.

  7. Tumours of the fetal body: a review

    Energy Technology Data Exchange (ETDEWEB)

    Avni, Fred E.; Massez, Anne; Cassart, Marie [University Clinics of Brussels - Erasme Hospital, Department of Medical Imaging, Brussels (Belgium)

    2009-11-15

    Tumours of the fetal body are rare, but lesions have been reported in all spaces, especially in the mediastinum, the pericardial space, the adrenals, the kidney, and the liver. Lymphangioma and teratoma are the commonest histological types encountered, followed by cardiac rhabdomyoma. Adrenal neuroblastoma is the commonest malignant tumour. Imaging plays an essential role in the detection and work-up of these tumours. In addition to assisting clinicians it also helps in counselling parents. Most tumours are detected by antenatal US, but fetal MRI is increasingly used as it brings significant additional information in terms of tumour extent, composition and complications. (orig.)

  8. Theory, simulation and experimental results of the acoustic detection of magnetization changes in superparamagnetic iron oxide

    Directory of Open Access Journals (Sweden)

    Borgert Jörn

    2011-06-01

    Full Text Available Abstract Background Magnetic Particle Imaging is a novel method for medical imaging. It can be used to measure the local concentration of a tracer material based on iron oxide nanoparticles. While the resulting images show the distribution of the tracer material in phantoms or anatomic structures of subjects under examination, no information about the tissue is being acquired. To expand Magnetic Particle Imaging into the detection of soft tissue properties, a new method is proposed, which detects acoustic emissions caused by magnetization changes in superparamagnetic iron oxide. Methods Starting from an introduction to the theory of acoustically detected Magnetic Particle Imaging, a comparison to magnetically detected Magnetic Particle Imaging is presented. Furthermore, an experimental setup for the detection of acoustic emissions is described, which consists of the necessary field generating components, i.e. coils and permanent magnets, as well as a calibrated microphone to perform the detection. Results The estimated detection limit of acoustic Magnetic Particle Imaging is comparable to the detection limit of magnetic resonance imaging for iron oxide nanoparticles, whereas both are inferior to the theoretical detection limit for magnetically detected Magnetic Particle Imaging. Sufficient data was acquired to perform a comparison to the simulated data. The experimental results are in agreement with the simulations. The remaining differences can be well explained. Conclusions It was possible to demonstrate the detection of acoustic emissions of magnetic tracer materials in Magnetic Particle Imaging. The processing of acoustic emission in addition to the tracer distribution acquired by magnetic detection might allow for the extraction of mechanical tissue parameters. Such parameters, like for example the velocity of sound and the attenuation caused by the tissue, might also be used to support and improve ultrasound imaging. However, the method

  9. Tumour location within the breast: Does tumour site have prognostic ability?

    Science.gov (United States)

    Rummel, Seth; Hueman, Matthew T; Costantino, Nick; Shriver, Craig D; Ellsworth, Rachel E

    2015-01-01

    Tumour location within the breast varies with the highest frequency in the upper outer quadrant (UOQ) and lowest frequency in the lower inner quadrant (LIQ). Whether tumour location is prognostic is unclear. To determine whether tumour location is prognostic, associations between tumour site and clinicopathological characteristics were evaluated. All patients enrolled in the Clinical Breast Care Project whose tumour site-UOQ, upper inner quadrant (UIQ), central, LIQ, lower outer quadrant (LOQ)-was determined by a single, dedicated breast pathologist were included in this study. Patients with multicentric disease (n = 122) or tumours spanning multiple quadrants (n = 381) were excluded from further analysis. Clinicopathological characteristics were analysed using chi-square tests for univariate analysis with multivariate analysis performed using principal components analysis (PCA) and multiple logistic regression. Significance was defined as P location, 30 had bilateral disease. Tumour location in the UOQ (51.5%) was significantly higher than in the UIQ (15.6%), LOQ (14.2%), central (10.6%), or LIQ (8.1%). Tumours in the central quadrant were significantly more likely to have higher tumour stage (P = 0.003) and size (P location as a prognostic factor revealed that although tumours in the central region are associated with less favourable outcome, these associations are not independent of location but rather driven by larger tumour size. Tumours in the central region are more difficult to detect mammographically, resulting in larger tumour size at diagnosis and thus less favourable prognosis. Together, these data demonstrate that tumour location is not an independent prognostic factor.

  10. System for detecting acoustic emissions in multianvil experiments: Application to deep seismicity in the Earth

    International Nuclear Information System (INIS)

    Jung, Haemyeong; Fei Yingwei; Silver, Paul G.; Green, Harry W.

    2006-01-01

    One of the major goals in the experimental study of deep earthquakes is to identify slip instabilities at high pressure and high temperature (HPHT) that might be responsible for the occurrence of earthquakes. Detecting acoustic emissions from a specimen during faulting provides unique constraints on the instability process. There are few experimental studies reporting acoustic emissions under HPHT conditions, due to technical challenges. And those studies have used only one or at most two acoustic sensors during the experiments. Such techniques preclude the accurate location of the acoustic emission source region and thus the ability to distinguish real signal from noise that may be coming from outside the sample. We have developed a system for detecting acoustic emissions at HPHT. Here we present a four-channel acoustic emission detecting system working in the HPHT octahedral multianvil apparatus. Each channel has high resolution (12 bits) and a sampling rate of 30 MHz. In experiments at the pressures up to 6 GPa and temperatures up to 770 deg. C, we have observed acoustic emissions under various conditions. Analyzing these signals, we are able to show that this system permits us to distinguish between signal and noise, locate the source of the acoustic emission, and obtain reliable data on the radiation pattern. This system has greatly improved our ability to study faulting instabilities under high pressure and high temperature

  11. Experimental results of passive vibro-acoustic leak detection in SFR steam generator mock-up

    International Nuclear Information System (INIS)

    Moriot, J.; Gastaldi, O.; Maxit, L.; Guyader, J-L.; Perisse, J.; Migot, B.

    2013-06-01

    Regarding to GEN 4 context, it is necessary to fulfil the high safety standards for sodium fast reactors (SFR), particularly against water-sodium reaction which may occur in the steam generator units (SGU) in case of leak. This reaction can cause severe damages in the component in a short time. Detecting such a leak by visual in-sodium inspection is impossible because of sodium opacity. Hydrogen detection is then used but the time response of this method can be high in certain operating conditions. Active and passive acoustic leak detection methods were studied before SUPERPHENIX plant shutdown in 1997 to detect a water-into-sodium leak with a short time response. In the context of the new R and D studies for SFR, an innovative passive vibro-acoustic method is developed in the framework of a Ph.D. thesis to match with GEN 4 safety requirements. The method consists in assuming that a small leak emits spherical acoustic waves in a broadband frequency domain, which propagate in the liquid sodium and excite the SGU cylindrical shell. These spatially coherent waves are supposed to be buried by a spatially incoherent background noise. The radial velocities of the shell is measured by an array of accelerometers positioned on the external envelop of the SGU and a beam forming treatment is applied to increase the signal-to-noise ratio (SNR) and to detect and localize the acoustic source. Previous numerical experiments were achieved and promising results were obtained. In this paper, experimental results of the proposed passive vibro-acoustic leak detection are presented. The experiment consists in a cylindrical water-filled steel pipe representing a model of SGU shell without tube bundle. A hydro-phone emitting an acoustic signal is used to simulate an acoustic monopole. Spatially uncorrelated noise or water-flow induced shell vibrations are considered as the background noise. The beam-forming method is applied to vibration signals measured by a linear array of

  12. Acoustic leak detection development in the USA

    International Nuclear Information System (INIS)

    Greene, D.A.; Malovrh, J.W.; Magee, P.M.

    1984-01-01

    Acoustic monitoring systems that detect and locate a leak of water/steam from a defective tube in an LMFBR steam generator have been developed in the United States. A low frequency (approx. 10 KHz) system was developed by General Electric, and a high frequency (200 to 300 KHz) system by Rockwell International with support from Argonne National Laboratory. A comprehensive base technology program provided absolute signal amplitudes, background noise amplitudes, and signal source-to-detector transfer functions. Field tests of these systems demonstrated an ability to detect and locate simulated leaks under operating and quiescent conditions in an LMFBR steam generator. (author)

  13. Ehrlich and sarcoma 180 tumour characterisation and early detection by 1H NMR-based metabonomics of mice serum

    International Nuclear Information System (INIS)

    Grandizoli, Caroline W.P. da S.; Simonelli, Fabio; Nagata, Noemi; Barison, Andersson; Carrenho, Luise Z.B.; Francisco, Thais M.G. de; Campos, Francinete R.; Santana Filho, Arquimedes P. de; Sassaki, Guilherme L.; Kreuger, Maria R.O.

    2014-01-01

    The success of cancer treatment is directly related to early detection before symptoms emerge, although nowadays few cancers can be detected early. In this sense, 1 H nuclear magnetic resonance ( 1 H NMR)-based metabonomics was used to identify metabolic changes in biofluid as a consequence of tumours growing in mice. Through partial least squares discriminant analysis (PLS-DA) analysis of 1 H NMR spectra from serum samples it was possible to diagnose Ehrlich ascites and Sarcoma 180 tumours five and ten days after cell inoculation, respectively. Lipids, lipoproteins and lactate were the main biomarkers at onset as well as in the progress of carcinogenic process. Thus, NMR-based metabonomics can be a valuable tool to study the effects of tumour establishment on the chemical composition of biofluids. (author)

  14. NON-DESTRUCTIVE LEAK DETECTION IN GALVANIZED IRON PIPE USING NONLINEAR ACOUSTIC MODULATION METHOD

    Directory of Open Access Journals (Sweden)

    Gigih Priyandoko

    2018-02-01

    Full Text Available Non-destructive testing is a wide group of analysis techniques used in science and industry to evaluate the properties of a structure without causing damage to it. The main objective of this project is to carry out experiment to detect leakage in pipeline using nonlinear acoustic modulation method. The nonlinear acoustic modulation approach with low frequency excitation and high frequency acoustic wave is used to reveal modulations in the presence of leak. The pipe used in this experiment was galvanized iron pipe. The experiment is started with the experiment of undamaged specimen and followed by the experiment of damaged specimen with manually applied leak. The results obtained are being observed and the difference between the specimen without leak and with leak can be distinguished. The distance of the leak and the distance of the outlet detected is nearly accurate to the exact location which is leak at 4.0 m and outlet at 6.0 m. Therefore, the results demonstrate that leakage can be detected using nonlinear acoustic modulation, and proved the objective of distinguish the difference between the results of specimen without leak and with leak has succeeded. The damage detection process can be eased with the knowledge on the signal features.

  15. Signal processing for passive detection and classification of underwater acoustic signals

    Science.gov (United States)

    Chung, Kil Woo

    2011-12-01

    This dissertation examines signal processing for passive detection, classification and tracking of underwater acoustic signals for improving port security and the security of coastal and offshore operations. First, we consider the problem of passive acoustic detection of a diver in a shallow water environment. A frequency-domain multi-band matched-filter approach to swimmer detection is presented. The idea is to break the frequency contents of the hydrophone signals into multiple narrow frequency bands, followed by time averaged (about half of a second) energy calculation over each band. Then, spectra composed of such energy samples over the chosen frequency bands are correlated to form a decision variable. The frequency bands with highest Signal/Noise ratio are used for detection. The performance of the proposed approach is demonstrated for experimental data collected for a diver in the Hudson River. We also propose a new referenceless frequency-domain multi-band detector which, unlike other reference-based detectors, does not require a diver specific signature. Instead, our detector matches to a general feature of the diver spectrum in the high frequency range: the spectrum is roughly periodic in time and approximately flat when the diver exhales. The performance of the proposed approach is demonstrated by using experimental data collected from the Hudson River. Moreover, we present detection, classification and tracking of small vessel signals. Hydroacoustic sensors can be applied for the detection of noise generated by vessels, and this noise can be used for vessel detection, classification and tracking. This dissertation presents recent improvements aimed at the measurement and separation of ship DEMON (Detection of Envelope Modulation on Noise) acoustic signatures in busy harbor conditions. Ship signature measurements were conducted in the Hudson River and NY Harbor. The DEMON spectra demonstrated much better temporal stability compared with the full ship

  16. Identification of microRNAs in blood and urine as tumour markers for the detection of urinary bladder cancer.

    Science.gov (United States)

    Tölle, Angelika; Jung, Monika; Rabenhorst, Silke; Kilic, Ergin; Jung, Klaus; Weikert, Steffen

    2013-10-01

    Since differential expression of microRNAs (miRNAs) has been found to be highly associated with several types of cancer, the goal of the present study was to identify an miRNA fingerprint as a non‑invasive diagnostic tool to detect urinary bladder cancer using the easily accessible samples of whole blood and urine. Blood and urine samples from 4 controls and from patients suffering from superficial and invasive bladder cancer were analyzed using miRNA microarray consisting of 754 human miRNAs from the Sanger database v14. Using RT‑qPCR technique, 6 of the differentially expressed miRNAs were validated in the controls (20 blood, 19 urine samples) and patients with superficial (18 blood, 16 urine samples) or invasive (20 blood and urine samples each) tumours. Three blood miRNAs (miR‑26b‑5p, miR‑144‑5p, miR‑374‑5p) were found to be significantly upregulated in invasive bladder tumour patients (Pbladder tumours with 94% specificity and 65% sensitivity. The urine miR‑1255b‑5p reached 68% specificity and 85% sensitivity in the diagnosis of invasive tumours. This pilot study represents the first characterization of an miRNA profile for urinary bladder tumours in whole blood samples. In addition, it was shown that invasive bladder tumours could be identified by differentially expressed urine miRNAs. Further studies are needed to test the clinical usefulness for bladder cancer detection and surveillance.

  17. Leak detection in gas pipeline by acoustic and signal processing - A review

    Science.gov (United States)

    Adnan, N. F.; Ghazali, M. F.; Amin, M. M.; Hamat, A. M. A.

    2015-12-01

    The pipeline system is the most important part in media transport in order to deliver fluid to another station. The weak maintenance and poor safety will contribute to financial losses in term of fluid waste and environmental impacts. There are many classifications of techniques to make it easier to show their specific method and application. This paper's discussion about gas leak detection in pipeline system using acoustic method will be presented in this paper. The wave propagation in the pipeline is a key parameter in acoustic method when the leak occurs and the pressure balance of the pipe will generated by the friction between wall in the pipe. The signal processing is used to decompose the raw signal and show in time- frequency. Findings based on the acoustic method can be used for comparative study in the future. Acoustic signal and HHT is the best method to detect leak in gas pipelines. More experiments and simulation need to be carried out to get the fast result of leaking and estimation of their location.

  18. Active acoustic leak detection for LMFBR steam generators. Pt. 7. Potential for small leak detection

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Yoshida, Kazuo

    1998-01-01

    In order to prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBR), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, is being developed. Previous studies have revealed that the active acoustic method can detect bubbles of 10 l/s (equivalence water leak rate about 10 g/s) within 10 seconds in practical steam generators. In order to prevent the expansion of damage to neighboring tubes, however, it is necessary to detect smaller leakage of water from heat transfer tubes. In this study, in order to evaluate the detection sensitivity of the active method, the signal processing methods for emitter and receiver sound and the detection method for leakage within 1 g/s are investigated experimentally, using an SG full-sector model that simulates the actual SGs. A typical result shows that detection of 0.4 l/s air bubbles (equivalent water leak rate about 0.4 g/s) takes about 80 seconds, which is shorter than the propagation time of damage to neighboring tubes. (author)

  19. Diffusion-weighted MRI for detecting prostate tumour in men at increased genetic risk

    International Nuclear Information System (INIS)

    Souza, Nandita M. de; Morgan, Veronica A.; Bancroft, Elizabeth; Sohaib, S. Aslam; Giles, Sharon L.; Kote-Jarai, Zsofia; Castro, Elena; Hazell, Steven; Jafar, Maysam; Eeles, Rosalind

    2014-01-01

    •Endorectal T2W + DW-MRI is potentially useful for prostate cancer screening.•MRI is specific for detecting prostate cancer in men with increased genetic risk.•Detection of prostate cancer in men at genetically low risk with MRI is limited. Endorectal T2W + DW-MRI is potentially useful for prostate cancer screening. MRI is specific for detecting prostate cancer in men with increased genetic risk. Detection of prostate cancer in men at genetically low risk with MRI is limited. Diffusion-weighted (DW)-MRI is invaluable in detecting prostate cancer. We determined its sensitivity and specificity and established interobserver agreement for detecting tumour in men with a family history of prostate cancer stratified by genetic risk. 51 men with a family history of prostate cancer underwent T2-W + DW-endorectal MRI at 3.0 T. Presence of tumour was noted at right and left apex, mid and basal prostate sextants by 2 independent observers, 1 experienced and the other inexperienced in endorectal MRI. Sensitivity and specificity against a 10-core sampling technique (lateral and medial cores at each level considered together) in men with >2× population risk based on 71 SNP analysis versus those with lower genetic risk scores was established. Interobserver agreement was determined at a subject level. Biopsies indicated cancer in 28 sextants in 13/51 men; 32 of 51 men had twice the population risk (>0.25) based on 71 SNP profiling. Sensitivity/specificity per-subject for patients was 90.0%/86.4% (high-risk) vs. 66.7%/100% (low-risk, observer 1) and 60.0%/86.3% (high-risk) vs. 33.3%/93.8% (low-risk, observer 2) with moderate overall inter-observer agreement (kappa = 0.42). Regional sensitivities/specificities for high-risk vs. low-risk for observer 1 apex 72.2%/100% [33.3%/100%], mid 100%/93.1% [100%/97.3%], base 16.7%/98.3% [0%/100%] and for observer 2 apex 36.4%/98.1% [0%/100%], mid 28.6%/96.5% [100%/100%], base 20%/100% [0%/97.3%] were poorer as they failed to detect

  20. Acoustic sodium-water reaction detection of the Phenix steam generators

    International Nuclear Information System (INIS)

    Carminati, M.; Martin, L.; Sauzaret, A.

    1990-01-01

    The systems for acoustic sodium-water reaction detection and hydrogen detection of the Phenix steam generators as well as systems for monitoring signals analysis and processing are described. It is reported that the results obtained during operation and calibration phases are very encouraging and that industrial equipment showing the same performance are being examined. 6 figs

  1. THE ACOUSTIC DETECTION OF INTRACRANIAL ANEURYSMS - A CLINICAL-STUDY

    NARCIS (Netherlands)

    VANBRUGGEN, AC; MOOIJ, JJA; JOURNEE, HL

    1991-01-01

    A new recording method for the acoustical detection of intracranial aneurysms is presented. A study examining the capability of the method to discriminate between patients with an aneurysm and control patients by a simple, objective parameter is reported. Sound signals were recorded over the eyes,

  2. Flow cytometric techniques for detection of candidate cancer stem cell subpopulations in canine tumour models.

    Science.gov (United States)

    Blacking, T M; Waterfall, M; Samuel, K; Argyle, D J

    2012-12-01

    The cancer stem cell (CSC) hypothesis proposes that tumour growth is maintained by a distinct subpopulation of 'CSC'. This study applied flow cytometric methods, reported to detect CSC in both primary and cultured cancer cells of other species, to identify candidate canine subpopulations. Cell lines representing diverse canine malignancies, and cells derived from spontaneous canine tumours, were evaluated for expression of stem cell-associated surface markers (CD34, CD44, CD117 and CD133) and functional properties [Hoecsht 33342 efflux, aldehyde dehydrogenase (ALDH) activity]. No discrete marker-defined subsets were identified within established cell lines; cells derived directly from spontaneous tumours demonstrated more heterogeneity, although this diminished upon in vitro culture. Functional assays produced variable results, suggesting context-dependency. Flow cytometric methods may be adopted to identify putative canine CSC. Whilst cell lines are valuable in assay development, primary cells may provide a more rewarding model for studying tumour heterogeneity in the context of CSC. However, it will be essential to fully characterize any candidate subpopulations to ensure that they meet CSC criteria. © 2011 Blackwell Publishing Ltd.

  3. Next-generation sequencing-based detection of circulating tumour DNA After allogeneic stem cell transplantation for lymphoma.

    Science.gov (United States)

    Herrera, Alex F; Kim, Haesook T; Kong, Katherine A; Faham, Malek; Sun, Heather; Sohani, Aliyah R; Alyea, Edwin P; Carlton, Victoria E; Chen, Yi-Bin; Cutler, Corey S; Ho, Vincent T; Koreth, John; Kotwaliwale, Chitra; Nikiforow, Sarah; Ritz, Jerome; Rodig, Scott J; Soiffer, Robert J; Antin, Joseph H; Armand, Philippe

    2016-12-01

    Next-generation sequencing (NGS)-based circulating tumour DNA (ctDNA) detection is a promising monitoring tool for lymphoid malignancies. We evaluated whether the presence of ctDNA was associated with outcome after allogeneic haematopoietic stem cell transplantation (HSCT) in lymphoma patients. We studied 88 patients drawn from a phase 3 clinical trial of reduced-intensity conditioning HSCT in lymphoma. Conventional restaging and collection of peripheral blood samples occurred at pre-specified time points before and after HSCT and were assayed for ctDNA by sequencing of the immunoglobulin or T-cell receptor genes. Tumour clonotypes were identified in 87% of patients with adequate tumour samples. Sixteen of 19 (84%) patients with disease progression after HSCT had detectable ctDNA prior to progression at a median of 3·7 months prior to relapse/progression. Patients with detectable ctDNA 3 months after HSCT had inferior progression-free survival (PFS) (2-year PFS 58% vs. 84% in ctDNA-negative patients, P = 0·033). In multivariate models, detectable ctDNA was associated with increased risk of progression/death (Hazard ratio 3·9, P = 0·003) and increased risk of relapse/progression (Hazard ratio 10·8, P = 0·0006). Detectable ctDNA is associated with an increased risk of relapse/progression, but further validation studies are necessary to confirm these findings and determine the clinical utility of NGS-based minimal residual disease monitoring in lymphoma patients after HSCT. © 2016 John Wiley & Sons Ltd.

  4. Process and device for detecting tumours of the eyes

    International Nuclear Information System (INIS)

    Safi, Nour; Thoreson, Elisabeth.

    1975-01-01

    This invention refers to a process and system for detecting tumours of the eye likely to take up radioelements. To this end, the invention proposes a detection process whereby a molecule labelled by a radioelement emitting Beta radiations having an energy spectrum extending beyond the Cerenkov threshold in the vitreous humor of the eye is introduced into the circulatory system of the patient under examination and whereby the Cerenkov emission is measured through the lens and pupil. A β-emitter radioelement and notably 32 P which is taken up energetically by high metabolic activity tissue can be employed in particular. The invention also proposes a system to use the process described above, comprising a dioptric system for transmitting the light produced in the vitreous humor by Cerenkov effect to a light detector of a type enabling the luminous flux it receives to be integrated [fr

  5. Ehrlich and sarcoma 180 tumour characterisation and early detection by {sup 1}H NMR-based metabonomics of mice serum

    Energy Technology Data Exchange (ETDEWEB)

    Grandizoli, Caroline W.P. da S.; Simonelli, Fabio; Nagata, Noemi; Barison, Andersson [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Quimica; Carrenho, Luise Z.B.; Francisco, Thais M.G. de; Campos, Francinete R. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Farmacia; Santana Filho, Arquimedes P. de; Sassaki, Guilherme L. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Bioquimica; Kreuger, Maria R.O. [Universidade do Vale do Itajai (UNIVALI), (Brazil). Centro de Ciencias da Saude

    2014-05-15

    The success of cancer treatment is directly related to early detection before symptoms emerge, although nowadays few cancers can be detected early. In this sense, {sup 1}H nuclear magnetic resonance ({sup 1}H NMR)-based metabonomics was used to identify metabolic changes in biofluid as a consequence of tumours growing in mice. Through partial least squares discriminant analysis (PLS-DA) analysis of {sup 1}H NMR spectra from serum samples it was possible to diagnose Ehrlich ascites and Sarcoma 180 tumours five and ten days after cell inoculation, respectively. Lipids, lipoproteins and lactate were the main biomarkers at onset as well as in the progress of carcinogenic process. Thus, NMR-based metabonomics can be a valuable tool to study the effects of tumour establishment on the chemical composition of biofluids. (author)

  6. Tumour screening by means of tomography methods

    International Nuclear Information System (INIS)

    Diederich, S.

    2005-01-01

    Tomography methods such as computer tomography (CT), magnetic resonance tomography (MRT), and sonography/ultrasound examinations make it possible to detect small asymptomatic tumours, thus potentially preventing their manifestation at an advanced stage and improving survival prospects for the patients concerned. There are data available on various common tumours which show that modern tomography methods are capable of detecting not only small asymptomatic tumours but also their benign precursors (e.g. polyps of the large intestine). This has been demonstrated for lung cancer, colon cancer and breast cancer. However, it has not been possible to date to show for any tomography method or any type of tumour that the systematic use of such diagnostic procedures does anything to lower the mortality rate for that tumour. For other types of tumour (pancreatic cancer, kidney cancer, ovary cancer) the above named methods are either not sufficiently sensitive or the body of data that has accumulated on their respective use is too small to judge the benefit of tomography screenings. Current technical developments make it appear probable that for many types of cancer the reliability with which small tumours can be detected will improve in future. Studies aimed at clarifying the potential of screenings for reducing mortality rates are already underway for lung cancer and would be worthwhile performing for other tumour types

  7. Micro-nano-bio acoustic system for the detection of foodborne pathogens in real samples.

    Science.gov (United States)

    Papadakis, George; Murasova, Pavla; Hamiot, Audrey; Tsougeni, Katerina; Kaprou, Georgia; Eck, Michael; Rabus, David; Bilkova, Zuzana; Dupuy, Bruno; Jobst, Gerhard; Tserepi, Angeliki; Gogolides, Evangelos; Gizeli, Electra

    2018-07-15

    The fast and efficient detection of foodborne pathogens is a societal priority, given the large number of food-poisoning outbreaks, and a scientific and technological challenge, given the need to detect as little as 1 viable cell in 25 gr of food. Here, we present the first approach that achieves the above goal, thanks to the use of a micro/nano-technology and the detection capability of acoustic wave sensors. Starting from 1 Salmonella cell in 25 ml of milk, we employ immuno-magnetic beads to capture cells after only 3 h of pre-enrichment and subsequently demonstrate efficient DNA amplification using the Loop Mediated Isothermal Amplification method (LAMP) and acoustic detection in an integrated platform, within an additional ½ h. The demonstrated 4 h sample-to-analysis time comes as a huge improvement to the current need of few days to obtain the same result. In addition, the work presents the first reported Lab-on-Chip platform that comprises an acoustic device as the sensing element, exhibiting impressive analytical features, namely, an acoustic limit of detection of 2 cells/μl or 3 aM of the DNA target and ability to detect in a label-free manner dsDNA amplicons in impure samples. The use of food samples together with the incorporation of the necessary pre-enrichment step and ability for multiple analysis with an internal control, make the proposed methodology highly relevant to real-world applications. Moreover, the work suggests that acoustic wave devices can be used as an attractive alternative to electrochemical sensors in integrated platforms for applications in food safety and the point-of-care diagnostics. Copyright © 2018. Published by Elsevier B.V.

  8. Micro-Electromechanical Acoustic Resonator Coated with Polyethyleneimine Nanofibers for the Detection of Formaldehyde Vapor

    Directory of Open Access Journals (Sweden)

    Da Chen

    2018-02-01

    Full Text Available We demonstrate a promising strategy to combine the micro-electromechanical film bulk acoustic resonator and the nanostructured sensitive fibers for the detection of low-concentration formaldehyde vapor. The polyethyleneimine nanofibers were directly deposited on the resonator surface by a simple electrospinning method. The film bulk acoustic resonator working at 4.4 GHz acted as a sensitive mass loading platform and the three-dimensional structure of nanofibers provided a large specific surface area for vapor adsorption and diffusion. The ultra-small mass change induced by the absorption of formaldehyde molecules onto the amine groups in polyethyleneimine was detected by measuring the frequency downshift of the film bulk acoustic resonator. The proposed sensor exhibits a fast, reversible and linear response towards formaldehyde vapor with an excellent selectivity. The gas sensitivity and the detection limit were 1.216 kHz/ppb and 37 ppb, respectively. The study offers a great potential for developing sensitive, fast-response and portable sensors for the detection of indoor air pollutions.

  9. Development of an incipient rotor crack detection method by acoustic emission techniques

    International Nuclear Information System (INIS)

    Le Reverend, D.; Massouri, M.H.

    1988-01-01

    The objective of the program presented is to develop a method of detection and monitoring of crack growth in machine rotor by application of acoustic emission techniques. This program is performed by R and D Division of Electricite de France, jointly with INSA de Lyon. The first task of the program is relative to the characterization of acoustic emission during a progressive tensile test performed on a NCT specimen. The second task of the program deals with the experimentation of acoustic emission techniques for the monitoring of a specimen during cycling bending tests. The last task of the program is relative to evaluation of application of acoustic emission techniques for a small rotor integrity monitoring during fatigue rotation tests [fr

  10. VIP secreting tumours in infancy

    International Nuclear Information System (INIS)

    Davies, R.P.; Slavotinek, J.P.; Dorney, S.F.A.

    1990-01-01

    Vasoactive intestinal polypeptide (VIP) secreting neural crest tumours are an uncommon but important treatable cause of intractable childhood diarrhoea. The radiological appearances of two cases are presented with a review of radiological findings in childhood VIP secreting neural crest tumours. Twenty eight cases of childhood VIP secreting neural crest tumours were reviewed. Nineteen (68%) were ganglioneuroblastomas and nine (32%) were ganglioneuromas. The majority of tumours (66%) were in a paravertebral location in the abdomen indicating that a search for such a tumour should be initiated at this site. Eighteen of the twenty eight cases reviewed discussed relevant radiological investigations. Calcification was detected in 50% of abdominal radiographs. Gut dilatation was often a prominent feature. A mass was detected in 5 of 5 cases where ultrasound findings were reported, and seven of seven cases with CT findings reported. Prior to the availability of CT and ultrasound the most useful investigation was IVU which demonstrated evidence of a mass in 5 of 9 cases. The presence of paravertebral calcification and gut dilatation on the plain radiograph of a child with intractable diarrhoea suggests the presence of a VIP secreting neural crest tumour. If an abdominal tumour is not found in the appropriate clinical setting and VIP levels are elevated, a widespread search of the paravertebral region is indicated. (orig.)

  11. Near-infrared laser, time domain, breast tumour detection system

    International Nuclear Information System (INIS)

    Joblin, A.J.

    1996-01-01

    image resolution using this technique is poor, being worse that S mm, with currently available time resolved detection system capabilities. However it was also found that tumour bodies smaller in size than the system resolution parameter produced a measurable change in the signal, which could be used to detect small tumour bodies. So while high resolution images of the breast are not possible, simple measurements to detect the presence of breast disease may be possible. This will require further work to allow the signal from breast disease to be distinguished without error from the expected variations in signal due to the variability in normal breast characteristics

  12. Acoustic leak detection and ultrasonic crack detection

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Claytor, T.N.; Groenwald, R.

    1983-10-01

    A program is under way to assess the effectiveness of current and proposed techniques for acoustic leak detection (ALD) in reactor coolant systems. An ALD facility has been constructed and tests have begun on five laboratory-grown cracks (three fatigue and two thermal-fatigue and two field-induced IGSCC specimens. After ultrasonic testing revealed cracks in the Georgia Power Co. HATCH-1 BWR recirculation header, the utility installed an ALD system. Data from HATCH-1 have given an indication of the background noise level at a BWR recirculation header sweepolet weld. The HATCH leak detection system was tested to determine the sensitivity and dynamic range. Other background data have been acquired at the Watts Bar Nuclear Reactor in Tennessee. An ANL waveguide system, including transducer and electronics, was installed and tested on an accumulator safety injection pipe. The possibility of using ultrasonic wave scattering patterns to discriminate between IGSCCs and geometric reflectors has been explored. Thirteen reflectors (field IGSCCs, graphite wool IGSCCs, weld roots, and slits) were examined. Work with cast stainless steel (SS) included sound velocity and attenuation in isotropic and anisotropic cast SS. Reducing anisotropy does not help reduce attenuation in large-grained material. Large artificial flaws (e.g., a 1-cm-deep notch with a 4-cm path) could not be detected in isotropic centrifugally cast SS (1 to 2-mm grains) by longitudinal or shear waves at frequencies of 1 MHz or greater, but could be detected with 0.5-MHz shear waves. 13 figures

  13. Application of acoustic leak detection technology for the detection and location of leaks in light water reactors

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Prine, D.; Mathieson, T.

    1988-10-01

    This report presents the results of a study to evaluate the adequacy of leak detection systems in light water reactors. The sources of numerous reported leaks and methods of detection have been documented. Research to advance the state of the art of acoustic leak detection is presented, and procedures for implementation are discussed. 14 refs., 70 figs., 10 tabs

  14. Volume growth rate of acoustic neurinomas

    International Nuclear Information System (INIS)

    Laasonen, E.M.; Troupp, H.

    1986-01-01

    Of 79 acoustic neurinomas seen between June 1980 and June 1984, at least two CT scans were available for each of 23 tumours (21 patients); the scans were performed at intervals of at least 6 months. The volume growth rate of the tumours was either moderate, with a volume doubling time ranging from 205 to 545 days, or slow, with a doubling time ranging from 1090 days to no observable growth. No single clinical, radiological or histological feature correlated with any type of growth rate. However, some conclusions were drawn. If a primary CT scan is negative, at least 1 year should elapse before it is worthwhile taking another scan, even though audiological findings suggest growth; after an apparently radical removal, at least 3 years should elapse before a check CT scan is worthwhile; and if a small acoustic neurinoma is diagnosed, but for some reason not operated upon, a second CT scan should be carried out 1 year later in order to reassess the case. (orig.)

  15. Numerical analysis of the resonance mechanism of the lumped parameter system model for acoustic mine detection

    International Nuclear Information System (INIS)

    Wang Chi; Zhou Yu-Qiu; Shen Gao-Wei; Wu Wen-Wen; Ding Wei

    2013-01-01

    The method of numerical analysis is employed to study the resonance mechanism of the lumped parameter system model for acoustic mine detection. Based on the basic principle of the acoustic resonance technique for mine detection and the characteristics of low-frequency acoustics, the ''soil-mine'' system could be equivalent to a damping ''mass-spring'' resonance model with a lumped parameter analysis method. The dynamic simulation software, Adams, is adopted to analyze the lumped parameter system model numerically. The simulated resonance frequency and anti-resonance frequency are 151 Hz and 512 Hz respectively, basically in agreement with the published resonance frequency of 155 Hz and anti-resonance frequency of 513 Hz, which were measured in the experiment. Therefore, the technique of numerical simulation is validated to have the potential for analyzing the acoustic mine detection model quantitatively. The influences of the soil and mine parameters on the resonance characteristics of the soil—mine system could be investigated by changing the parameter setup in a flexible manner. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  16. Suitability of a tumour-mimicking material for the evaluation of high-intensity focused ultrasound ablation under magnetic resonance guidance

    International Nuclear Information System (INIS)

    Pichardo, S; Kivinen, J; Curiel, L; Melodelima, D

    2013-01-01

    This study tests the suitability of a tumour-mimic for targeting magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU). An agarose-based tumour-mimic was injected as a warm solution that polymerized in tissue. Thermal characteristics and acoustic absorption of the mimic were observed within the values reported for tissues. The relaxation times at 3T were 1679 ± 15 ms for T1 and 41 ± 1 ms for T2. The mimic was clearly visible on in vivo images. With lower contrast the tumour-mimic was visible on T2-weighted images, where it was possible to detect the ablated tissue surrounding the mimic after sonications. HIFU sonications were performed to induce thermal ablation on and around the mimic using a Sonalleve system (Philips). MR thermometry maps were performed during HIFU. The average temperature when the sonication was done at the tumour-mimic was 67.6 ± 8.0 °C in vitro and 67.6 ± 5.0 °C in vivo. The average temperature for sonications at tissues was 68.4 ± 8.7 °C in vitro (liver) and 66.0 ± 2.6 °C in vivo (muscle), with no significant difference between tissue and tumour-mimic (p > 0.05). The tumour-mimic behaviour when using MR-guided HIFU was similar to tissues, showing that this mimic can be used as an alternative to tumour models for validating MR-guided HIFU devices targeting. (paper)

  17. Optimized acoustic biochip integrated with microfluidics for biomarkers detection in molecular diagnostics.

    Science.gov (United States)

    Papadakis, G; Friedt, J M; Eck, M; Rabus, D; Jobst, G; Gizeli, E

    2017-09-01

    The development of integrated platforms incorporating an acoustic device as the detection element requires addressing simultaneously several challenges of technological and scientific nature. The present work was focused on the design of a microfluidic module, which, combined with a dual or array type Love wave acoustic chip could be applied to biomedical applications and molecular diagnostics. Based on a systematic study we optimized the mechanics of the flow cell attachment and the sealing material so that fluidic interfacing/encapsulation would impose minimal losses to the acoustic wave. We have also investigated combinations of operating frequencies with waveguide materials and thicknesses for maximum sensitivity during the detection of protein and DNA biomarkers. Within our investigations neutravidin was used as a model protein biomarker and unpurified PCR amplified Salmonella DNA as the model genetic target. Our results clearly indicate the need for experimental verification of the optimum engineering and analytical parameters, in order to develop commercially viable systems for integrated analysis. The good reproducibility of the signal together with the ability of the array biochip to detect multiple samples hold promise for the future use of the integrated system in a Lab-on-a-Chip platform for application to molecular diagnostics.

  18. Impact damage detection in light composite sandwich panels using piezo-based nonlinear vibro-acoustic modulations

    International Nuclear Information System (INIS)

    Pieczonka, L; Ukowski, P; Klepka, A; Staszewski, W J; Uhl, T; Aymerich, F

    2014-01-01

    The nonlinear vibro-acoustic modulation technique is used for impact damage detection in light composite sandwich panels. The method utilizes piezo-based low-frequency vibration and high-frequency ultrasonic excitations. The work presented focuses on the analysis of modulation intensity. The results show that the method can be used for impact damage detection reliably separating damage-related from vibro-acoustic modulations from other intrinsic nonlinear modulations. (paper)

  19. Results of investigations within the IWGFR benchmark test acoustic boiling noise detection

    International Nuclear Information System (INIS)

    Mauersberger, H.; Froehlich, K.J.

    1989-01-01

    The present paper deals with investigations of acoustic signals from a boiling experiment performed on the KNS I loop at KfK Karlsruhe. Signals have been analysed in frequency as well as in time domain. Signal characteristics successfully used to detect the boiling process have been found in time domain. A proposal for in-service boiling monitoring by acoustic means is briefly described. (author). 10 refs, 16 figs, 1 tab

  20. Haemorrhagic acoustic neuroma with features of a vascular malformation. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Benhaiem-Sigaux, N. [Dept. of Pathology, Hopital Henri Mondor, Creteil (France); Ricolfi, F. [Dept. of Neuroradiology, Henri Mondor Hospital, Creteil (France); Torres-Diaz, A.; Keravel, Y. [Dept. of Neurosurgery, Henri Mondo Hospital, Creteil (France); Poirier, J. [Dept. of Histology, Pitie-Salpetriere Hospital, Paris (France)

    1999-10-01

    A 55-year-old man with hearing loss presented with vertigo and vomiting. CT tomography and MRI demonstrated a cerebellopontine angle mass with foci of haemorrhage. An angiomatous tumour, with large abnormal veins adhering to the capsule, was completely removed. Histologically, the tumour was an acoustic neuroma with abnormal vascularisation and limited intratumoral haemorrhage. (orig.)

  1. Haemorrhagic acoustic neuroma with features of a vascular malformation. A case report

    International Nuclear Information System (INIS)

    Benhaiem-Sigaux, N.; Ricolfi, F.; Torres-Diaz, A.; Keravel, Y.; Poirier, J.

    1999-01-01

    A 55-year-old man with hearing loss presented with vertigo and vomiting. CT tomography and MRI demonstrated a cerebellopontine angle mass with foci of haemorrhage. An angiomatous tumour, with large abnormal veins adhering to the capsule, was completely removed. Histologically, the tumour was an acoustic neuroma with abnormal vascularisation and limited intratumoral haemorrhage. (orig.)

  2. AMADEUS—The acoustic neutrino detection test system of the ANTARES deep-sea neutrino telescope

    Science.gov (United States)

    Aguilar, J. A.; Al Samarai, I.; Albert, A.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardid, M.; Assis Jesus, A. C.; Astraatmadja, T.; Aubert, J.-J.; Auer, R.; Barbarito, E.; Baret, B.; Basa, S.; Bazzotti, M.; Bertin, V.; Biagi, S.; Bigongiari, C.; Bou-Cabo, M.; Bouwhuis, M. C.; Brown, A.; Brunner, J.; Busto, J.; Camarena, F.; Capone, A.; Cârloganu, C.; Carminati, G.; Carr, J.; Cassano, B.; Castorina, E.; Cavasinni, V.; Cecchini, S.; Ceres, A.; Charvis, Ph.; Chiarusi, T.; Chon Sen, N.; Circella, M.; Coniglione, R.; Costantini, H.; Cottini, N.; Coyle, P.; Curtil, C.; de Bonis, G.; Decowski, M. P.; Dekeyser, I.; Deschamps, A.; Distefano, C.; Donzaud, C.; Dornic, D.; Drouhin, D.; Eberl, T.; Emanuele, U.; Ernenwein, J.-P.; Escoffier, S.; Fehr, F.; Fiorello, C.; Flaminio, V.; Fritsch, U.; Fuda, J.-L.; Gay, P.; Giacomelli, G.; Gómez-González, J. P.; Graf, K.; Guillard, G.; Halladjian, G.; Hallewell, G.; van Haren, H.; Heijboer, A. J.; Heine, E.; Hello, Y.; Hernández-Rey, J. J.; Herold, B.; Hößl, J.; de Jong, M.; Kalantar-Nayestanaki, N.; Kalekin, O.; Kappes, A.; Katz, U.; Keller, P.; Kooijman, P.; Kopper, C.; Kouchner, A.; Kretschmer, W.; Lahmann, R.; Lamare, P.; Lambard, G.; Larosa, G.; Laschinsky, H.; Le Provost, H.; Lefèvre, D.; Lelaizant, G.; Lim, G.; Lo Presti, D.; Loehner, H.; Loucatos, S.; Louis, F.; Lucarelli, F.; Mangano, S.; Marcelin, M.; Margiotta, A.; Martinez-Mora, J. A.; Mazure, A.; Mongelli, M.; Montaruli, T.; Morganti, M.; Moscoso, L.; Motz, H.; Naumann, C.; Neff, M.; Ostasch, R.; Palioselitis, D.; Păvălaş, G. E.; Payre, P.; Petrovic, J.; Picot-Clemente, N.; Picq, C.; Popa, V.; Pradier, T.; Presani, E.; Racca, C.; Radu, A.; Reed, C.; Riccobene, G.; Richardt, C.; Rujoiu, M.; Ruppi, M.; Russo, G. V.; Salesa, F.; Sapienza, P.; Schöck, F.; Schuller, J.-P.; Shanidze, R.; Simeone, F.; Spurio, M.; Steijger, J. J. M.; Stolarczyk, Th.; Taiuti, M.; Tamburini, C.; Tasca, L.; Toscano, S.; Vallage, B.; van Elewyck, V.; Vannoni, G.; Vecchi, M.; Vernin, P.; Wijnker, G.; de Wolf, E.; Yepes, H.; Zaborov, D.; Zornoza, J. D.; Zúñiga, J.

    2011-01-01

    The AMADEUS (ANTARES Modules for the Acoustic Detection Under the Sea) system which is described in this article aims at the investigation of techniques for acoustic detection of neutrinos in the deep sea. It is integrated into the ANTARES neutrino telescope in the Mediterranean Sea. Its acoustic sensors, installed at water depths between 2050 and 2300 m, employ piezo-electric elements for the broad-band recording of signals with frequencies ranging up to 125 kHz. The typical sensitivity of the sensors is around -145 dB re 1 V/μPa (including preamplifier). Completed in May 2008, AMADEUS consists of six “acoustic clusters”, each comprising six acoustic sensors that are arranged at distances of roughly 1 m from each other. Two vertical mechanical structures (so-called lines) of the ANTARES detector host three acoustic clusters each. Spacings between the clusters range from 14.5 to 340 m. Each cluster contains custom-designed electronics boards to amplify and digitise the acoustic signals from the sensors. An on-shore computer cluster is used to process and filter the data stream and store the selected events. The daily volume of recorded data is about 10 GB. The system is operating continuously and automatically, requiring only little human intervention. AMADEUS allows for extensive studies of both transient signals and ambient noise in the deep sea, as well as signal correlations on several length scales and localisation of acoustic point sources. Thus the system is excellently suited to assess the background conditions for the measurement of the bipolar pulses expected to originate from neutrino interactions.

  3. Development of an acoustic steam generator leak detection system using delay-and-sum beamformer

    International Nuclear Information System (INIS)

    Chikazawa, Yoshitaka

    2009-01-01

    A new acoustic steam generator leak detection system using delay-and-sum beamformer is proposed. The major advantage of the delay-and-sum beamformer is it could provide information of acoustic source direction. An acoustic source of a sodium-water reaction is supposed to be localized while the background noise of the steam generator operation is uniformly distributed in the steam generator tube region. Therefore the delay-and-sum beamformer could distinguish the acoustic source of the sodium-water reaction from steam generator background noise. In this paper, results from numerical analyses are provided to show fundamental feasibility of the new method. (author)

  4. Acoustic particle detection - From early ideas to future benefits

    International Nuclear Information System (INIS)

    Nahnhauer, Rolf

    2012-01-01

    The history of acoustic neutrino detection technology is shortly reviewed from the first ideas 50 years ago to the detailed R and D programs of the last decade. The physics potential of ultra-high energy neutrino interaction studies is discussed for some examples. Ideas about the necessary detector size and suitable design are presented.

  5. Tumour risk associated with use of cellular telephones or cordless desktop telephones

    Directory of Open Access Journals (Sweden)

    Söderqvist Fredrik

    2006-10-01

    Full Text Available Abstract Background The use of cellular and cordless telephones has increased dramatically during the last decade. There is concern of health problems such as malignant diseases due to microwave exposure during the use of these devices. The brain is the main target organ. Methods Since the second part of the 1990's we have performed six case-control studies on this topic encompassing use of both cellular and cordless phones as well as other exposures. Three of the studies concerned brain tumours, one salivary gland tumours, one non-Hodgkin lymphoma (NHL and one testicular cancer. Exposure was assessed by self-administered questionnaires. Results Regarding acoustic neuroma analogue cellular phones yielded odds ratio (OR = 2.9, 95 % confidence interval (CI = 2.0–4.3, digital cellular phones OR = 1.5, 95 % CI = 1.1–2.1 and cordless phones OR = 1.5, 95 % CI = 1.04–2.0. The corresponding results were for astrocytoma grade III-IV OR = 1.7, 95 % CI = 1.3–2.3; OR = 1.5, 95 % CI = 1.2–1.9 and OR = 1.5, 95 % CI = 1.1–1.9, respectively. The ORs increased with latency period with highest estimates using > 10 years time period from first use of these phone types. Lower ORs were calculated for astrocytoma grade I-II. No association was found with salivary gland tumours, NHL or testicular cancer although an association with NHL of T-cell type could not be ruled out. Conclusion We found for all studied phone types an increased risk for brain tumours, mainly acoustic neuroma and malignant brain tumours. OR increased with latency period, especially for astrocytoma grade III-IV. No consistent pattern of an increased risk was found for salivary gland tumours, NHL, or testicular cancer.

  6. Effect of passive acoustic sampling methodology on detecting bats after declines from white nose syndrome

    Science.gov (United States)

    Coleman, Laci S.; Ford, W. Mark; Dobony, Christopher A.; Britzke, Eric R.

    2014-01-01

    Concomitant with the emergence and spread of white-nose syndrome (WNS) and precipitous decline of many bat species in North America, natural resource managers need modified and/or new techniques for bat inventory and monitoring that provide robust occupancy estimates. We used Anabat acoustic detectors to determine the most efficient passive acoustic sampling design for optimizing detection probabilities of multiple bat species in a WNS-impacted environment in New York, USA. Our sampling protocol included: six acoustic stations deployed for the entire duration of monitoring as well as a 4 x 4 grid and five transects of 5-10 acoustic units that were deployed for 6-8 night sample durations surveyed during the summers of 2011-2012. We used Program PRESENCE to determine detection probability and site occupancy estimates. Overall, the grid produced the highest detection probabilities for most species because it contained the most detectors and intercepted the greatest spatial area. However, big brown bats (Eptesicus fuscus) and species not impacted by WNS were detected easily regardless of sampling array. Endangered Indiana (Myotis sodalis) and little brown (Myotis lucifugus) and tri-colored bats (Perimyotis subflavus) showed declines in detection probabilities over our study, potentially indicative of continued WNS-associated declines. Identification of species presence through efficient methodologies is vital for future conservation efforts as bat populations decline further due to WNS and other factors.   

  7. Automated acoustic analysis in detection of spontaneous swallows in Parkinson's disease.

    Science.gov (United States)

    Golabbakhsh, Marzieh; Rajaei, Ali; Derakhshan, Mahmoud; Sadri, Saeed; Taheri, Masoud; Adibi, Peyman

    2014-10-01

    Acoustic monitoring of swallow frequency has become important as the frequency of spontaneous swallowing can be an index for dysphagia and related complications. In addition, it can be employed as an objective quantification of ingestive behavior. Commonly, swallowing complications are manually detected using videofluoroscopy recordings, which require expensive equipment and exposure to radiation. In this study, a noninvasive automated technique is proposed that uses breath and swallowing recordings obtained via a microphone located over the laryngopharynx. Nonlinear diffusion filters were used in which a scale-space decomposition of recorded sound at different levels extract swallows from breath sounds and artifacts. This technique was compared to manual detection of swallows using acoustic signals on a sample of 34 subjects with Parkinson's disease. A speech language pathologist identified five subjects who showed aspiration during the videofluoroscopic swallowing study. The proposed automated method identified swallows with a sensitivity of 86.67 %, a specificity of 77.50 %, and an accuracy of 82.35 %. These results indicate the validity of automated acoustic recognition of swallowing as a fast and efficient approach to objectively estimate spontaneous swallow frequency.

  8. In vivo detection of small tumour lesions by multi-pinhole SPECT applying a (99m)Tc-labelled nanobody targeting the Epidermal Growth Factor Receptor.

    Science.gov (United States)

    Krüwel, Thomas; Nevoltris, Damien; Bode, Julia; Dullin, Christian; Baty, Daniel; Chames, Patrick; Alves, Frauke

    2016-02-25

    The detection of tumours in an early phase of tumour development in combination with the knowledge of expression of tumour markers such as epidermal growth factor receptor (EGFR) is an important prerequisite for clinical decisions. In this study we applied the anti-EGFR nanobody (99m)Tc-D10 for visualizing small tumour lesions with volumes below 100 mm(3) by targeting EGFR in orthotopic human mammary MDA-MB-468 and MDA-MB-231 and subcutaneous human epidermoid A431 carcinoma mouse models. Use of nanobody (99m)Tc-D10 of a size as small as 15.5 kDa enables detection of tumours by single photon emission computed tomography (SPECT) imaging already 45 min post intravenous administration with high tumour uptake (>3% ID/g) in small MDA-MB-468 and A431 tumours, with tumour volumes of 52.5 mm(3) ± 21.2 and 26.6 mm(3) ± 16.7, respectively. Fast blood clearance with a serum half-life of 4.9 min resulted in high in vivo contrast and ex vivo tumour to blood and tissue ratios. In contrast, no accumulation of (99m)Tc-D10 in MDA-MB-231 tumours characterized by a very low expression of EGFR was observed. Here we present specific and high contrast in vivo visualization of small human tumours overexpressing EGFR by preclinical multi-pinhole SPECT shortly after administration of anti-EGFR nanobody (99m)Tc-D10.

  9. In vivo detection of small tumour lesions by multi-pinhole SPECT applying a 99mTc-labelled nanobody targeting the Epidermal Growth Factor Receptor

    Science.gov (United States)

    Krüwel, Thomas; Nevoltris, Damien; Bode, Julia; Dullin, Christian; Baty, Daniel; Chames, Patrick; Alves, Frauke

    2016-01-01

    The detection of tumours in an early phase of tumour development in combination with the knowledge of expression of tumour markers such as epidermal growth factor receptor (EGFR) is an important prerequisite for clinical decisions. In this study we applied the anti-EGFR nanobody 99mTc-D10 for visualizing small tumour lesions with volumes below 100 mm3 by targeting EGFR in orthotopic human mammary MDA-MB-468 and MDA-MB-231 and subcutaneous human epidermoid A431 carcinoma mouse models. Use of nanobody 99mTc-D10 of a size as small as 15.5 kDa enables detection of tumours by single photon emission computed tomography (SPECT) imaging already 45 min post intravenous administration with high tumour uptake (>3% ID/g) in small MDA-MB-468 and A431 tumours, with tumour volumes of 52.5 mm3 ± 21.2 and 26.6 mm3 ± 16.7, respectively. Fast blood clearance with a serum half-life of 4.9 min resulted in high in vivo contrast and ex vivo tumour to blood and tissue ratios. In contrast, no accumulation of 99mTc-D10 in MDA-MB-231 tumours characterized by a very low expression of EGFR was observed. Here we present specific and high contrast in vivo visualization of small human tumours overexpressing EGFR by preclinical multi-pinhole SPECT shortly after administration of anti-EGFR nanobody 99mTc-D10. PMID:26912069

  10. Acoustic firearm discharge detection and classification in an enclosed environment

    Energy Technology Data Exchange (ETDEWEB)

    Luzi, Lorenzo; Gonzalez, Eric; Bruillard, Paul; Prowant, Matthew; Skorpik, James; Hughes, Michael; Child, Scott; Kist, Duane; McCarthy, John E.

    2016-05-01

    Two different signal processing algorithms are described for detection and classification of acoustic signals generated by firearm discharges in small enclosed spaces. The first is based on the logarithm of the signal energy. The second is a joint entropy. The current study indicates that a system using both signal energy and joint entropy would be able to both detect weapon discharges and classify weapon type, in small spaces, with high statistical certainty.

  11. Effect of a Background Noise on the Acoustic Leak Detection Methodology for a SFR Steam Generator

    International Nuclear Information System (INIS)

    Kim, Tae-Joon; Jeong, Ji-Young; Kim, Jong-Man

    2007-01-01

    The protection of a water/steam leak into a sodium in the SFR SG at an early phase of a leak origin depends on a fast response and sensitivity of a leak detection system not to a response against the several kinds of noises. The subject in this study is to introduce a detection performance by using our developed acoustic leak detection methodology discriminated by a backpropagation neural network according to a preprocessing of the 1/6 Octave band analysis or 1/12 Octave band analysis and the x n method defined by us. It was used for the acoustic signals generated from the simulation works which are the noises of an artificial background such as a scratching, a hammering on a steel structure and so on. In a previous study, we showed that the performance of a LabVIEW tool embedded with the developed acoustic leak detection methodology detected the SWR leak signals

  12. Value of skeletal scintiscanning in cases of primary bone tumours and tumourous alterations

    International Nuclear Information System (INIS)

    Sokolowski, U.

    1982-01-01

    In the course of an investigation on the storage behaviour of primary bone tumours and tumourous bone alterations the skeletal scintigrams of a total of 26 patients were evaluated. Bone scintiscanning was done according to current practice after injection of an average amount of 10mCi sup(99m)Tc-MDP, followed by a semiquantitative evaluation. In all cases of malignant bone tumours there was fond to be increased storage of radionuclide; with benign bone alterations this was so in 70 per cent of cases. To differentiate between benign and malignant tumours respectively inflammatory bone diseases was not as a rule possible; however, the investigation yielded additional information completing the X-ray findings essentially. Thus very high storage of radioactivity was established for all osteosarcomas, whereas benign bone growths exhibited more circumscribed accumulations of activity. Skeletal scintiscanning for diagnostical purposes is particularly informative as to the early detection of bone foci evading X-ray diagnosis, more accurate delimitation of tumourous processes, and course control of tumours tending to degenerate. (orig./MG) [de

  13. Mobile phones and head tumours. The discrepancies in cause-effect relationships in the epidemiological studies - how do they arise?

    OpenAIRE

    Levis, Angelo G; Minicuci, Nadia; Ricci, Paolo; Gennaro, Valerio; Garbisa, Spiridione

    2011-01-01

    Abstract Background Whether or not there is a relationship between use of mobile phones (analogue and digital cellulars, and cordless) and head tumour risk (brain tumours, acoustic neuromas, and salivary gland tumours) is still a matter of debate; progress requires a critical analysis of the methodological elements necessary for an impartial evaluation of contradictory studies. Methods A close examination of the protocols and results from all case-control and cohort studies, pooled- and meta-...

  14. Translational illusion of acoustic sources by transformation acoustics.

    Science.gov (United States)

    Sun, Fei; Li, Shichao; He, Sailing

    2017-09-01

    An acoustic illusion of creating a translated acoustic source is designed by utilizing transformation acoustics. An acoustic source shifter (ASS) composed of layered acoustic metamaterials is designed to achieve such an illusion. A practical example where the ASS is made with naturally available materials is also given. Numerical simulations verify the performance of the proposed device. The designed ASS may have some applications in, e.g., anti-sonar detection.

  15. A direct comparison of CellSearch and ISET for circulating tumour-cell detection in patients with metastatic carcinomas

    Science.gov (United States)

    Farace, F; Massard, C; Vimond, N; Drusch, F; Jacques, N; Billiot, F; Laplanche, A; Chauchereau, A; Lacroix, L; Planchard, D; Le Moulec, S; André, F; Fizazi, K; Soria, J C; Vielh, P

    2011-01-01

    Background: Circulating tumour cells (CTCs) can provide information on patient prognosis and treatment efficacy. However, there is no universal method to detect CTC currently available. Here, we compared the performance of two CTC detection systems based on the expression of the EpCAM antigen (CellSearch assay) or on cell size (ISET assay). Methods: Circulating tumour cells were enumerated in 60 patients with metastatic carcinomas of breast, prostate and lung origins using CellSearch according to the manufacturer's protocol and ISET by studying cytomorphology and immunolabelling with anti-cytokeratin or lineage-specific antibodies. Results: Concordant results were obtained in 55% (11 out of 20) of the patients with breast cancer, in 60% (12 out of 20) of the patients with prostate cancer and in only 20% (4 out of 20) of lung cancer patients. Conclusion: Our results highlight important discrepancies between the numbers of CTC enumerated by both techniques. These differences depend mostly on the tumour type. These results suggest that technologies limiting CTC capture to EpCAM-positive cells, may present important limitations, especially in patients with metastatic lung carcinoma. PMID:21829190

  16. Hyperparathyroidism-jaw tumour syndrome detected by aggressive generalized osteitis fibrosa cystica.

    Science.gov (United States)

    Guerrouani, Alae; Rzin, Abdelkader; El Khatib, Karim

    2013-01-01

    Severe hyperparathyroidism can affect bone metabolism and be in the origine of multiple brown tumours (generalized osteitis fibrosa cystica). When associated with fibro-ossifying tumours of the jaw, it realizes a rare genetic syndrome referred as Hyperparathyroidism-jaw tumour HPT-JT. We report the case of a patient we treated for HPT-JT, and literature review.

  17. Acoustic tomography for decay detection in black cherry trees

    Science.gov (United States)

    Xiping Wang; Jan Wiedenbeck; Shanqing Liang

    2009-01-01

    This study investigated the potential of using acoustic tomography for detecting internal decay in high-value hardwood trees in the forest. Twelve black cherry (Prunus serotina) trees that had a wide range of physical characteristics were tested in a stand of second-growth hardwoods in Kane, PA, using a PiCUS Sonic Tomograph tool. The trees were felled after the field...

  18. Mobile phone use and risk of brain tumours

    International Nuclear Information System (INIS)

    Lahkola, A.

    2010-05-01

    Mobile phone use has increased rapidly worldwide since the 1990's. As mobile telephones are used close to the head, the exposure to the radiofrequency radiation emitted by mobile phones has been suggested as a possible risk factor for brain tumours. The effect of mobile phone use on risk of brain tumours, particularly gliomas and meningiomas as well as acoustic neuromas, was evaluated using both a case-control approach and a meta-analysis. In addition, one of the most important sources of error in a case-control study, selection bias due to differential participation, was assessed in a subset of the case-control data. The risk of glioma and meningioma in relation to mobile phone use was investigated in population-based case-control studies conducted in five North European countries. All these countries used a common protocol and were included in a multinational study on mobile phone use and brain tumours, the INTERPHONE study, coordinated by the International Agency for Research on Cancer (IARC). Cases (1,521 gliomas and 1,209 meningiomas) were identified mostly from hospitals and controls (3,299) from national population registers or general practitioners' patient lists. Detailed history of mobile phone use was obtained in personal interviews. Mobile phone use was assessed using several exposure indicators, such as regular use (phone use at least once a week for at least six months), duration of use as well as cumulative number of hours and calls. To comprehensively evaluate the effect of mobile phone use on risk of brain tumours, the existing evidence from the epidemiological studies published on the issue was combined using meta-analysis. In the analysis, a pooled estimate was calculated for all brain tumours combined, and also separately for the three most common tumour types, glioma, meningioma and acoustic neuroma using inverse variance-weighted method. Pooled estimate was also obtained for different telephone types (NMT and GSM) and by the location of the

  19. Detection of HPV-associated oropharyngeal tumours in a 16-year cohort : more than meets the eye

    NARCIS (Netherlands)

    Melchers, L. J.; Mastik, M. F.; Cameron, B. Samaniego; van Dijk, B. A. C.; de Bock, G. H.; van der Laan, B. F. A. M.; van der Vegt, B.; Speel, E. J. M.; Roodenburg, J. L. N.; Witjes, M. J. H.; Schuuring, E.

    2015-01-01

    Background: Accurate assessment of the prevalence of the human papilloma virus (HPV) in oropharyngeal tumours (OpSCC) is important because HPV-positive OpSCC are consistently associated with an improved overall survival. Recently, an algorithm has become available that reliably detects clinically

  20. Metrizamide cisternography in the diagnosis of acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Servo, A.; Porras, M.; Jaeaeskinen, J.

    1981-02-01

    Seventy-three cisternographies with metrizamide were performed on 69 patients, mainly for diagnosis of an acoustic neurinoma. Of the 31 patients with pathological findings on cisternography 26 underwent surgery for 23 acoustic neurinomas, one neurinoma of the facial nerve, and two meningiomas. For diagnosing small tumours of the cerebellopontine cistern, cisternography is superior to all other neuroradiological methods. Tomography of the porus acusticus internus and CT scanning are the initial radiological methods in patients with signs of cerebellopontine angle lesions; if no lesion is disclosed by these two methods cisternography with metrizamide should be performed to exclude a small tumor, particularly a small acoustic neurinoma.

  1. Status of U.S. evaluations of acoustic detection of in-sodium water leaks

    International Nuclear Information System (INIS)

    Fletcher, F.L.; Neely, H.H.

    1990-01-01

    An overview of the United States testing program to evaluate acoustic leak detection and location systems on simulated water leaks in functional liquid sodium steam generators is provided. Testing was conducted on the modular hockey stick steam generator during the large leak test program in the LLTR, on the CRBR prototype hockey stick steam generators in SCTI, on a double wall tube steam generator installed in EBR-II and on the helical coil steam generator tested in SCTI. These test programs have demonstrated the acoustic leak detection system potential, however, additional development is required before the system can perform to its effective and required potential. (author). 6 figs

  2. Hydrogen and acoustic detection in steam generators of Super Phenix power plant

    International Nuclear Information System (INIS)

    Kong, N.; Le Bris, A.; Berthier, P.

    1986-05-01

    During the isothermal tests of Super-Phenix, two types of measurements were made on the steam generators with regard to the detection of water leaks into the sodium: - the first measurements enabled us to determine the characteristics (sensitivity, response time) of the hydrogen detectors that are already operational for the filling with water and the power operation of the steam generators. They also provided the basis for developing a prototype system for detecting very small water leaks (microleak phase). The other measurements concern the qualification tests of acoustic detectors which have been fitted for the first time to a major industrial installation. The results obtained are very satisfactory but final validation of the acoustic method will only occur after the full-power tests [fr

  3. Interleukin 21 controls tumour growth and tumour immunosurveillance in colitis-associated tumorigenesis in mice.

    Science.gov (United States)

    Jauch, Dominik; Martin, Maria; Schiechl, Gabriela; Kesselring, Rebecca; Schlitt, Hans Jürgen; Geissler, Edward K; Fichtner-Feigl, Stefan

    2011-12-01

    Colitis-associated tumorigenesis is a balance between proliferation of tumour cells and tumour immunosurveillance. The role of T-helper-cell-derived cytokines in tumour growth is not fully understood. In this study the authors investigated the influence of interleukin (IL) 21 on intestinal tumorigenesis. Chronic colitis was induced in IL-21(-/-) and littermate control wild-type mice with three cycles of 1.5% dextran sulphate sodium (DSS) over 7 days followed by 7 days of drinking water. Mice received an azoxymethane injection on day 0 of DSS-colitis to induce tumorigenesis. Immunohistochemistry was performed on inflamed and tumour-bearing areas of colons. Cytokine expression of isolated colonic CD4 T cells was determined by ELISA. Cytotoxic capacity of isolated colonic CD8 T cells targeting tumour cells was evaluated by flow cytometry and quantitative cytotoxicity assay. Apoptosis of tumour cells was determined by TUNEL assay of colonic sections. Increasing expression of IL-21 was observed in chronic colitis, which showed functional importance, since IL-21 deficiency prevented chronic DSS-colitis development. Further, in the absence of IL-21, significantly fewer tumour nodules were detected, despite a similar extent of intestinal inflammation. In wild-type mice, 8.6±1.9 tumour nodules were found compared with 1.0±1.2 in IL-21-deficient mice. In tumour-bearing IL-21-deficient mice, intestinal inflammation was restored and partly dependent on interferon (IFN)-γ, whereas the inflammation in wild-type mice showed high IL-17A concentrations. In these rare tumours in IL-21-deficient mice, tumour cell proliferation (Ki-67) was decreased, while cell apoptosis was increased, compared with wild-type mice. Increased IFNγ expression in tumour-bearing IL-21-deficient mice led to increased tumour immunosurveillance mediated by cytotoxic CD8CD103 T cells targeting E-cadherin(+) colonic tumour cells and therefore limited tumour growth. These results indicate that IL-21

  4. Positron emission tomography (PET) and pancreatic tumours

    International Nuclear Information System (INIS)

    Montravers, F.; Kerrou, K.; Grahek, D.; Gutman, F.; Beco, V. de; Talbot, J.N.

    2005-01-01

    Neoplasms of the pancreas may originate front both exocrine and endocrine cells but in 90% of the cases, they correspond to ductal adenocarcinomas. For adenocarcinomas, the major indication of FDG-PET corresponds to the pre-operative staging because unexpected distant metastases can be detected by FDG-PET in about 20 to 40% of the cases, which results in avoidance of unnecessary surgical procedures. FDG PET is also useful in evaluation of the treatment effect, monitoring after the operation and detection of recurrent pancreatic cancers. For the characterisation of the pancreatic tumour, the performance of FDG-PET is sometimes limited due to poor cellularity, hyperglycemia or inflammatory processes. especially for large tumours and is indicated only in cases of doubtful results of CT or MRI. For endocrine pancreatic tumours, FDG-PET is useful only in case of poorly-differentiated and aggressive tumours. F-DOPA PET can he useful, complementary to pentetreotide scintigraphy, in well-differentiated endocrine tumours. (authors)

  5. Imaging oxygenation of human tumours

    International Nuclear Information System (INIS)

    Padhani, Anwar R.; Krohn, Kenneth A.; Lewis, Jason S.; Alber, Markus

    2007-01-01

    Tumour hypoxia represents a significant challenge to the curability of human tumours leading to treatment resistance and enhanced tumour progression. Tumour hypoxia can be detected by non-invasive and invasive techniques but the inter-relationships between these remains largely undefined. 18 F-MISO and Cu-ATSM-PET, and BOLD-MRI are the lead contenders for human application based on their non-invasive nature, ease of use and robustness, measurement of hypoxia status, validity, ability to demonstrate heterogeneity and general availability, these techniques are the primary focus of this review. We discuss where developments are required for hypoxia imaging to become clinically useful and explore potential new uses for hypoxia imaging techniques including biological conformal radiotherapy. (orig.)

  6. Early tumour detection: a transillumination, time-resolved technique

    International Nuclear Information System (INIS)

    Behin-Ain, S.; Van Doorn, T.; Patterson, J.

    2000-01-01

    Full text: Research into transillumination techniques for the detection of tumours in soft tissue has been ongoing for over 70 years. The resolution and contrast, however, remain severely limited by scatter. Single photon detection techniques, with ideally infinite extinction coefficients, have been proposed to accumulate sub-hertz photon transmitted frequencies in the early part of a transmitted pulse. Computer based simulations have been undertaken to examine the theoretical performance requirements of the detector and the resultant image qualities that may be expected with this imaging technique. This paper reports on the computational techniques required for implementing these simulations in an efficient manner. Controlled Monte Carlo (CMC) and Convolution of Layers (CL) techniques were employed to constrain the photon to those having more chance of detection and hence enhance the detection statistics. Extrapolation techniques are proposed to reconstruct the early part of the temporal profile. Computational methods were implemented to evaluate Path Integrals, which are otherwise overly complex to evaluate. CMC and CL reduce the computational time by more than 10 orders of magnitude by only tracking those photons more likely to reach the detector. In the case of an optically thick medium with high scattering coefficient, extrapolation techniques are used to reconstruct the early part of temporal profile. Analytical solutions were found to be too involved for the simplest geometries. However the CL and implementation of computational techniques make Path integrals a useful analytical tool to compliment full Monte Carlo techniques. Results have shown that these methods collectively enable detection of small inhomogeneites within soft tissues. Reduced computation times and full reconstruction of the temporal profile of transmitted photons through optically thick medium enable fast simulations of single photon detectors to be achieved with the above described

  7. New comprehensive denaturing-gradient-gel-electrophoresis assay for KRAS mutation detection applied to paraffin-embedded tumours

    NARCIS (Netherlands)

    Hayes, VM; Westra, JL; Verlind, E; Bleeker, W; Plukker, JT; Hofstra, RMW; Buys, CHCM

    2000-01-01

    A comprehensive mutation detection assay is presented for the entire coding region and all splice site junctions of the KRAS oncogene. The assay is based on denaturing gradient gel electrophoresis and applicable to archival paraffin-embedded tumour material. All KRAS amplicons are analysed within

  8. Automatic tumour volume delineation in respiratory-gated PET images

    International Nuclear Information System (INIS)

    Gubbi, Jayavardhana; Palaniswami, Marimuthu; Kanakatte, Aparna; Mani, Nallasamy; Kron, Tomas; Binns, David; Srinivasan, Bala

    2011-01-01

    Positron emission tomography (PET) is a state-of-the-art functional imaging technique used in the accurate detection of cancer. The main problem with the tumours present in the lungs is that they are non-stationary during each respiratory cycle. Tumours in the lungs can get displaced up to 2.5 cm during respiration. Accurate detection of the tumour enables avoiding the addition of extra margin around the tumour that is usually used during radiotherapy treatment planning. This paper presents a novel method to detect and track tumour in respiratory-gated PET images. The approach followed to achieve this task is to automatically delineate the tumour from the first frame using support vector machines. The resulting volume and position information from the first frame is used in tracking its motion in the subsequent frames with the help of level set (LS) deformable model. An excellent accuracy of 97% is obtained using wavelets and support vector machines. The volume calculated as a result of the machine learning (ML) stage is used as a constraint for deformable models and the tumour is tracked in the remaining seven phases of the respiratory cycle. As a result, the complete information about tumour movement during each respiratory cycle is available in relatively short time. The combination of the LS and ML approach accurately delineated the tumour volume from all frames, thereby providing a scope of using PET images towards planning an accurate and effective radiotherapy treatment for lung cancer.

  9. Supratentorial tumours. Part II: tumors of neurolglial cells

    International Nuclear Information System (INIS)

    Sage, M.R.

    1991-01-01

    Tumors arising from neuroglial cells are the most common primary brain tumours, representing approximately 45% of all tumours. A simplified classification of these tumours is given, based on the degree of anaplasia. Both computed tomography and magnetic resonance imaging appearance of such lesions is presented and the relevance of these techniques in the detection and differential diagnosis of neuroglial cells tumours is discussed. 39 refs., 1 tab., 11 figs

  10. Radiation-induced brain tumours: potential late complications of radiation therapy for brain tumours

    International Nuclear Information System (INIS)

    Nishio, S.; Morioka, T.; Inamura, T.; Takeshita, I.; Fukui, M.; Sasaki, M.; Nakamura, K.; Wakisaka, S.

    1998-01-01

    The development of neoplasms subsequent to therapeutic cranial irradiation is a rare but serious and potentially fatal complication. In this study, we retrospectively reviewed the clinical and pathological aspects of 11 patients who underwent cranial irradiation (range, 24-110 cGy) to treat their primary disease and thereafter developed secondary tumours within a span of 13 years. All tumours arose within the previous radiation fields, and satisfied the widely used criteria for the definition of radiation-induced neoplasms. There was no sex predominance (M: 5, F: 6) and the patients tended to be young at irradiation (1.3 - 42 years; median age: 22 years). The median latency period before the detection of the secondary tumour was 14.5 years (range: 6.5 - 24 years). Meningiomas developed in 5 patients, sarcomas in 4, and malignant gliomas in 2. A pre-operative diagnosis of a secondary tumour was correctly obtained in 10 patients based on the neuro-imaging as well as nuclear medicine findings. All patients underwent a surgical removal of the secondary tumour, 3 underwent additional chemotherapy, and one received stereotactic secondary irradiation therapy. During a median of 2 years of follow-up review after the diagnosis of a secondary tumour, 3 patients died related to the secondary tumours (2 sarcomas, 1 glioblastoma), one died of a recurrent primary glioma, while the remaining 7 have been alive for from 10 months to 12 years after being treated for the secondary tumours (median: 3 years). Based on these data, the clinicopathological characteristics and possible role of treatment for secondary tumours are briefly discussed. (author)

  11. Deep Recurrent Neural Network-Based Autoencoders for Acoustic Novelty Detection

    Directory of Open Access Journals (Sweden)

    Erik Marchi

    2017-01-01

    Full Text Available In the emerging field of acoustic novelty detection, most research efforts are devoted to probabilistic approaches such as mixture models or state-space models. Only recent studies introduced (pseudo-generative models for acoustic novelty detection with recurrent neural networks in the form of an autoencoder. In these approaches, auditory spectral features of the next short term frame are predicted from the previous frames by means of Long-Short Term Memory recurrent denoising autoencoders. The reconstruction error between the input and the output of the autoencoder is used as activation signal to detect novel events. There is no evidence of studies focused on comparing previous efforts to automatically recognize novel events from audio signals and giving a broad and in depth evaluation of recurrent neural network-based autoencoders. The present contribution aims to consistently evaluate our recent novel approaches to fill this white spot in the literature and provide insight by extensive evaluations carried out on three databases: A3Novelty, PASCAL CHiME, and PROMETHEUS. Besides providing an extensive analysis of novel and state-of-the-art methods, the article shows how RNN-based autoencoders outperform statistical approaches up to an absolute improvement of 16.4% average F-measure over the three databases.

  12. Deep Recurrent Neural Network-Based Autoencoders for Acoustic Novelty Detection.

    Science.gov (United States)

    Marchi, Erik; Vesperini, Fabio; Squartini, Stefano; Schuller, Björn

    2017-01-01

    In the emerging field of acoustic novelty detection, most research efforts are devoted to probabilistic approaches such as mixture models or state-space models. Only recent studies introduced (pseudo-)generative models for acoustic novelty detection with recurrent neural networks in the form of an autoencoder. In these approaches, auditory spectral features of the next short term frame are predicted from the previous frames by means of Long-Short Term Memory recurrent denoising autoencoders. The reconstruction error between the input and the output of the autoencoder is used as activation signal to detect novel events. There is no evidence of studies focused on comparing previous efforts to automatically recognize novel events from audio signals and giving a broad and in depth evaluation of recurrent neural network-based autoencoders. The present contribution aims to consistently evaluate our recent novel approaches to fill this white spot in the literature and provide insight by extensive evaluations carried out on three databases: A3Novelty, PASCAL CHiME, and PROMETHEUS. Besides providing an extensive analysis of novel and state-of-the-art methods, the article shows how RNN-based autoencoders outperform statistical approaches up to an absolute improvement of 16.4% average F -measure over the three databases.

  13. Mobile phones and head tumours. The discrepancies in cause-effect relationships in the epidemiological studies - how do they arise?

    Science.gov (United States)

    Levis, Angelo G; Minicuci, Nadia; Ricci, Paolo; Gennaro, Valerio; Garbisa, Spiridione

    2011-06-17

    Whether or not there is a relationship between use of mobile phones (analogue and digital cellulars, and cordless) and head tumour risk (brain tumours, acoustic neuromas, and salivary gland tumours) is still a matter of debate; progress requires a critical analysis of the methodological elements necessary for an impartial evaluation of contradictory studies. A close examination of the protocols and results from all case-control and cohort studies, pooled- and meta-analyses on head tumour risk for mobile phone users was carried out, and for each study the elements necessary for evaluating its reliability were identified. In addition, new meta-analyses of the literature data were undertaken. These were limited to subjects with mobile phone latency time compatible with the progression of the examined tumours, and with analysis of the laterality of head tumour localisation corresponding to the habitual laterality of mobile phone use. Blind protocols, free from errors, bias, and financial conditioning factors, give positive results that reveal a cause-effect relationship between long-term mobile phone use or latency and statistically significant increase of ipsilateral head tumour risk, with biological plausibility. Non-blind protocols, which instead are affected by errors, bias, and financial conditioning factors, give negative results with systematic underestimate of such risk. However, also in these studies a statistically significant increase in risk of ipsilateral head tumours is quite common after more than 10 years of mobile phone use or latency. The meta-analyses, our included, examining only data on ipsilateral tumours in subjects using mobile phones since or for at least 10 years, show large and statistically significant increases in risk of ipsilateral brain gliomas and acoustic neuromas. Our analysis of the literature studies and of the results from meta-analyses of the significant data alone shows an almost doubling of the risk of head tumours induced by

  14. Recent experiments on acoustic leak detection

    International Nuclear Information System (INIS)

    Voss, J.; Arnaoutis, N.

    1984-01-01

    In the ASB-sodium loop a series of injection experiments with water, helium, argon and nitrogen was performed. The aim of these tests was to get: a comparison of the acoustic signals, generated by water and gas injections with regard to intensity and frequency content; an experimental basis for the design of an acoustic calibration source. The experimental set-up, the variation parameters and first results will be discussed. The principal design of an acoustic calibration source and its range of application will be given. (author)

  15. Detection and Characterization of Circulating Tumour Cells in Multiple Myeloma

    Directory of Open Access Journals (Sweden)

    Liangxuan Zhang

    2016-06-01

    Full Text Available Multiple myeloma (MM remains an incurable disease despite recent therapeutic improvements. The ability to detect and characterize MM circulating tumour cells (CTCs in peripheral blood provides an alternative to replace or augment invasive bone marrow (BM biopsies with a simple blood draw, providing real-time, clinically relevant information leading to improved disease manage‐ ment and therapy selection. Here we have developed and qualified an enrichment-free, cell-based immunofluores‐ cence MM CTC assay that utilizes an automated digital pathology algorithm to distinguish MM CTCs from white blood cells (WBCs on the basis of CD138 and CD45 expression levels, as well as a number of morphological parameters. These MM CTCs were further characterized for expression of phospho-ribosomal protein S6 (pS6 as a readout for PI3K/AKT pathway activation. Clinical feasi‐ bility of the assay was established by testing blood samples from a small cohort of patients, where we detected popu‐ lations of both CD138pos and CD138neg MM CTCs. In this study, we developed an immunofluorescent cell-based assay to detect and characterize CTCs in MM.

  16. Detection and Characterization of Circulating Tumour Cells in Multiple Myeloma

    Directory of Open Access Journals (Sweden)

    Liangxuan Zhang

    2016-01-01

    Full Text Available Multiple myeloma (MM remains an incurable disease despite recent therapeutic improvements. The ability to detect and characterize MM circulating tumour cells (CTCs in peripheral blood provides an alternative to replace or augment invasive bone marrow (BM biopsies with a simple blood draw, providing real-time, clinically relevant information leading to improved disease management and therapy selection. Here we have developed and qualified an enrichment-free, cell-based immunofluorescence MM CTC assay that utilizes an automated digital pathology algorithm to distinguish MM CTCs from white blood cells (WBCs on the basis of CD138 and CD45 expression levels, as well as a number of morphological parameters. These MM CTCs were further characterized for expression of phospho-ribosomal protein S6 (pS6 as a readout for PI3K/AKT pathway activation. Clinical feasibility of the assay was established by testing blood samples from a small cohort of patients, where we detected populations of both CD138 pos and CD138 neg MM CTCs. In this study, we developed an immunofluorescent cell-based assay to detect and characterize CTCs in MM.

  17. Acoustic emission

    International Nuclear Information System (INIS)

    Nichols, R.W.

    1976-01-01

    The volume contains six papers which together provide an overall review of the inspection technique known as acoustic emission or stress wave emission. The titles are: a welder's introduction to acoustic emission technology; use of acoustic emission for detection of defects as they arise during fabrication; examples of laboratory application and assessment of acoustic emission in the United Kingdom; (Part I: acoustic emission behaviour of low alloy steels; Part II: fatigue crack assessment from proof testing and continuous monitoring); inspection of selected areas of engineering structures by acoustic emission; Japanese experience in laboratory and practical applications of acoustic emission to welded structures; and ASME acoustic emission code status. (U.K.)

  18. Acoustic analysis assessment in speech pathology detection

    Directory of Open Access Journals (Sweden)

    Panek Daria

    2015-09-01

    Full Text Available Automatic detection of voice pathologies enables non-invasive, low cost and objective assessments of the presence of disorders, as well as accelerating and improving the process of diagnosis and clinical treatment given to patients. In this work, a vector made up of 28 acoustic parameters is evaluated using principal component analysis (PCA, kernel principal component analysis (kPCA and an auto-associative neural network (NLPCA in four kinds of pathology detection (hyperfunctional dysphonia, functional dysphonia, laryngitis, vocal cord paralysis using the a, i and u vowels, spoken at a high, low and normal pitch. The results indicate that the kPCA and NLPCA methods can be considered a step towards pathology detection of the vocal folds. The results show that such an approach provides acceptable results for this purpose, with the best efficiency levels of around 100%. The study brings the most commonly used approaches to speech signal processing together and leads to a comparison of the machine learning methods determining the health status of the patient

  19. Acoustic emission technique for characterisation of deformation, fatigue, fracture and phase transformation and for leak detection with high sensitivity- our experiences

    International Nuclear Information System (INIS)

    Jayakumar, T.; Mukhopadhyay, C.K.; Baldev Raj

    1996-01-01

    Acoustic emission technique has been used for studying tensile deformation, fracture behaviour, detection and assessment of fatigue crack growth and α-martensite phase transformation in austenitic alloys. A methodology for amplification of weak acoustic emission signals has been established. Acoustic emission technique with advanced spectral analysis has enabled detection with high sensitivity of minute leaks in noisy environments. (author)

  20. Tumour targeting with systemically administered bacteria.

    LENUS (Irish Health Repository)

    Morrissey, David

    2012-01-31

    Challenges for oncology practitioners and researchers include specific treatment and detection of tumours. The ideal anti-cancer therapy would selectively eradicate tumour cells, whilst minimising side effects to normal tissue. Bacteria have emerged as biological gene vectors with natural tumour specificity, capable of homing to tumours and replicating locally to high levels when systemically administered. This property enables targeting of both the primary tumour and secondary metastases. In the case of invasive pathogenic species, this targeting strategy can be used to deliver genes intracellularly for tumour cell expression, while non-invasive species transformed with plasmids suitable for bacterial expression of heterologous genes can secrete therapeutic proteins locally within the tumour environment (cell therapy approach). Many bacterial genera have been demonstrated to localise to and replicate to high levels within tumour tissue when intravenously (IV) administered in rodent models and reporter gene tagging of bacteria has permitted real-time visualisation of this phenomenon. Live imaging of tumour colonising bacteria also presents diagnostic potential for this approach. The nature of tumour selective bacterial colonisation appears to be tumour origin- and bacterial species- independent. While originally a correlation was drawn between anaerobic bacterial colonisation and the hypoxic nature of solid tumours, it is recently becoming apparent that other elements of the unique microenvironment within solid tumours, including aberrant neovasculature and local immune suppression, may be responsible. Here, we consider the pre-clinical data supporting the use of bacteria as a tumour-targeting tool, recent advances in the area, and future work required to develop it into a beneficial clinical tool.

  1. A low molecular weight zinc{sup 2+}-dipicolylamine-based probe detects apoptosis during tumour treatment better than an annexin V-based probe

    Energy Technology Data Exchange (ETDEWEB)

    Palmowski, Karin [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); University of Heidelberg, Department of Pneumology, Thoraxklinik Heidelberg, Heidelberg (Germany); Rix, Anne; Lederle, Wiltrud; Kiessling, Fabian [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); Behrendt, Florian F. [RWTH-Aachen University, Department of Nuclear Medicine, Aachen (Germany); Mottaghy, Felix M. [RWTH-Aachen University, Department of Nuclear Medicine, Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, Maastricht (Netherlands); Gray, Brian D. [Molecular Targeting Technologies, Inc., West Chester, PA (United States); Pak, Koon Y. [University Medical Center Heidelberg, Academic Radiology Baden-Baden, Diagnostic and Interventional Radiology, Heidelberg (Germany); Palmowski, Moritz [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); RWTH-Aachen University, Department of Nuclear Medicine, Aachen (Germany); University Medical Center Heidelberg, Academic Radiology Baden-Baden, Diagnostic and Interventional Radiology, Heidelberg (Germany)

    2014-02-15

    Molecular imaging of apoptosis is frequently discussed for monitoring cancer therapies. Here, we compare the low molecular weight phosphatidylserine-targeting ligand zinc{sup 2+}-dipicolylamine (Zn{sup 2+}-DPA) with the established but reasonably larger protein annexin V. Molecular apoptosis imaging with the fluorescently labelled probes annexin V (750 nm, 36 kDa) and Zn{sup 2+}-DPA (794 nm, 1.84 kDa) was performed in tumour-bearing mice (A431). Three animal groups were investigated: untreated controls and treated tumours after 1 or 4 days of anti-angiogenic therapy (SU11248). Additionally, μPET with {sup 18} F-FDG was performed. Imaging data were displayed as tumour-to-muscle ratio (TMR) and validated by quantitative immunohistochemistry. Compared with untreated control tumours, TUNEL staining indicated significant apoptosis after 1 day (P < 0.05) and 4 days (P < 0.01) of treatment. Concordantly, Zn{sup 2+}-DPA uptake increased significantly after 1 day (P < 0.05) and 4 days (P < 0.01). Surprisingly, annexin V failed to detect significant differences between control and treated animals. Contrary to the increasing uptake of Zn{sup 2+}-DPA, {sup 18} F-FDG tumour uptake decreased significantly at days 1 (P < 0.05) and 4 (P < 0.01). Increase in apoptosis during anti-angiogenic therapy was detected significantly better with the low molecular weight probe Zn{sup 2+}-DPA than with the annexin V-based probe. Additionally, significant treatment effects were detectable as early using Zn{sup 2+}-DPA as with measurements of the glucose metabolism using {sup 18} F-FDG. (orig.)

  2. Active acoustic leak detection for LMFBR steam generator. Sound attenuation due to bubbles

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Sakuma, Toshio

    1995-01-01

    In the steam generators (SG) of LMFBR, it is necessary to detect the leakage of water from tubes of heat exchangers as soon as it occurs. The active acoustic detection method has drawn general interest owing to its short response time and reduction of the influence of background noise. In this paper, the application of the active acoustic detection method for SG is proposed, and sound attenuation by bubbles is investigated experimentally. Furthermore, using the SG sector model, sound field characteristics and sound attenuation characteristics due to injection of bubbles are studied. It is clarified that the sound attenuation depends upon bubble size as well as void fraction, that the distance attenuation of sound in the SG model containing heat transfer tubes is 6dB for each two-fold increase of distance, and that emitted sound attenuates immediately upon injection of bubbles. (author)

  3. Acoustic Emission Technology and Application

    International Nuclear Information System (INIS)

    Joo, Y. S.; Lim, S. H.; Eom, H. S.; Kim, J. H.; Jung, H. K.

    2003-10-01

    Acoustic emission is the elastic wave that is generated by the rapid release of energy from the localized sources within a material. After the observation of acoustic emission phenomenon in 1950, the research and further investigation had been performed. Acoustic emission examination becomes a rapidly matured nondestructive testing method with demonstrated capabilities for characterizing material behavior and for detecting the defect. It is of interest as a possible passive monitoring technique for detecting, locating and characterizing the defects in component and structure. Acoustic emission technology has recently strengthened the on-line monitoring application for the detection of incipient failures and the assurance of structural integrity. The field of acoustic emission testing is still growing vigorously and presents many challenges. Especially, acoustic emission has been successfully applied in the leak detection of primary pressure boundary of nuclear power plants. In this state-of-art report, the principle, measurement and field applications of acoustic emission technique is reviewed and summarized. Acoustic emission technology will contribute to the assurance of nuclear safety as the on-line monitoring technique of structural integrity of NSSS components and structures

  4. Endogenous biotin expression in renal and testicular tumours and literature review.

    Science.gov (United States)

    Fahmy, Nader; Woo, Mark; Alameldin, Mona; Lee, Joe King; MacDonald, Kyle; Goneau, Lee W; Cadieux, Peter; Burton, Jeremy; Pautler, Stephen

    2014-07-01

    The aim of this study was to examine endogenous biotin levels in tumour specimens collected from patients with renal and testicular tumours and compare them to the surrounding non-neoplastic surgical margin. Frozen samples were obtained from the Ontario Tumour Bank. Renal and testicular tumour tissue were included in this study. Normal tissue from the negative surgical margins of each tumour served as a control. Biotin detection in tissue specimens was determined using immunohistochemistry (IHC). Specimens collected from 56 patients (36 men and 20 women) were included in this study. Histopathology of the 52 renal tumours included 31 (60%) conventional type RCC, 5 (10%) chromophobe RCC, 5 (10%) papillary RCC, 1 (2%) oncocytoma and 10 (19%) upper tract urothelial carcinoma (UC). The 4 testicular tumours included 1 seminomatous (25%) germ cell tumour and 3 (75%) non seminomatous germ cell tumours. No biotin signal was perceived in all tested tumour samples. Endogenous biotin expression was detected in the matching non-neoplastic surgical margin of tested renal tissues. This lack of staining may prove to be a valuable tool in future studies.

  5. Acoustic building infiltration measurement system

    Science.gov (United States)

    Muehleisen, Ralph T.; Raman, Ganesh

    2018-04-10

    Systems and methods of detecting and identifying a leak from a container or building. Acoustic pressure and velocity are measured. Acoustic properties are acquired from the measured values. The acoustic properties are converted to infiltration/leakage information. Nearfield Acoustic Holography (NAH) may be one method to detect the leakages from a container by locating the noise sources.

  6. Optimizing surface acoustic wave sensors for trace chemical detection

    Energy Technology Data Exchange (ETDEWEB)

    Frye, G.C.; Kottenstette, R.J.; Heller, E.J. [and others

    1997-06-01

    This paper describes several recent advances for fabricating coated surface acoustic wave (SAW) sensors for applications requiring trace chemical detection. Specifically, we have demonstrated that high surface area microporous oxides can provide 100-fold improvements in SAW sensor responses compared with more typical polymeric coatings. In addition, we fabricated GaAs SAW devices with frequencies up to 500 MHz to provide greater sensitivity and an ideal substrate for integration with high-frequency electronics.

  7. Second primary tumours in oral cancer

    NARCIS (Netherlands)

    van der Waal, I.; de Bree, R.

    2010-01-01

    Second primary tumours in patients treated for oral cancer occur at a rate of 3% to 7% per year. The majority of these tumours show up at least six months after the detection of the primary and are often located in the upper aerodigestive tract. Cessation of smoking habits may reduce the risk of the

  8. A hydrophone prototype for ultra high energy neutrino acoustic detection

    International Nuclear Information System (INIS)

    Cotrufo, A.; Plotnikov, A.; Yershova, O.; Anghinolfi, M.; Piombo, D.

    2009-01-01

    The design of an air-backed fiber-optic hydrophone is presented. With respect to the previous models this prototype is optimized to provide a bandwidth sufficiently large to detect acoustic signals produced by high energy hadronic showers in water. In addiction to the geometrical configuration and to the choice of the materials, the preliminary results of the measured performances in air are presented.

  9. A hydrophone prototype for ultra high energy neutrino acoustic detection

    Energy Technology Data Exchange (ETDEWEB)

    Cotrufo, A. [University of Genoa, Department of Physics, Via Dodecaneso 33, I-16146 (Italy)], E-mail: cotrufo@ge.infn.it; Plotnikov, A.; Yershova, O. [GSI Helmholtz Centre for Heavy Ion Research, GmbH Planckstrasse1, 64291 Darmstadt (Germany); Anghinolfi, M.; Piombo, D. [INFN, University of Genoa, Department of Physics, Via Dodecaneso 33, I-16146 (Italy)

    2009-06-01

    The design of an air-backed fiber-optic hydrophone is presented. With respect to the previous models this prototype is optimized to provide a bandwidth sufficiently large to detect acoustic signals produced by high energy hadronic showers in water. In addiction to the geometrical configuration and to the choice of the materials, the preliminary results of the measured performances in air are presented.

  10. Acoustic neurinoma surgery in Belfast 1986-1989.

    Science.gov (United States)

    Cullen, J R; Byrnes, D P; Kerr, A G; Walby, A P

    1992-04-01

    Forty-seven acoustic neurinoma tumours have been operated on in 46 patients in the years 1987-1989. This is a considerable increase over the prevalence in the preceding ten years. Twenty-six were classified as large tumours, 18 as medium and one was small. Surgical excision was complete in 16 and incomplete in 31 cases. Two patients died in the early postoperative period. Facial nerve function was preserved in 36 (80%) of cases; of these 27 (60%) had good function and nine (20%) fair function. Useful hearing was prevented in only two patients. The overall complication rate has been low and often of a transitory nature.

  11. Bat detective-Deep learning tools for bat acoustic signal detection.

    Science.gov (United States)

    Mac Aodha, Oisin; Gibb, Rory; Barlow, Kate E; Browning, Ella; Firman, Michael; Freeman, Robin; Harder, Briana; Kinsey, Libby; Mead, Gary R; Newson, Stuart E; Pandourski, Ivan; Parsons, Stuart; Russ, Jon; Szodoray-Paradi, Abigel; Szodoray-Paradi, Farkas; Tilova, Elena; Girolami, Mark; Brostow, Gabriel; Jones, Kate E

    2018-03-01

    Passive acoustic sensing has emerged as a powerful tool for quantifying anthropogenic impacts on biodiversity, especially for echolocating bat species. To better assess bat population trends there is a critical need for accurate, reliable, and open source tools that allow the detection and classification of bat calls in large collections of audio recordings. The majority of existing tools are commercial or have focused on the species classification task, neglecting the important problem of first localizing echolocation calls in audio which is particularly problematic in noisy recordings. We developed a convolutional neural network based open-source pipeline for detecting ultrasonic, full-spectrum, search-phase calls produced by echolocating bats. Our deep learning algorithms were trained on full-spectrum ultrasonic audio collected along road-transects across Europe and labelled by citizen scientists from www.batdetective.org. When compared to other existing algorithms and commercial systems, we show significantly higher detection performance of search-phase echolocation calls with our test sets. As an example application, we ran our detection pipeline on bat monitoring data collected over five years from Jersey (UK), and compared results to a widely-used commercial system. Our detection pipeline can be used for the automatic detection and monitoring of bat populations, and further facilitates their use as indicator species on a large scale. Our proposed pipeline makes only a small number of bat specific design decisions, and with appropriate training data it could be applied to detecting other species in audio. A crucial novelty of our work is showing that with careful, non-trivial, design and implementation considerations, state-of-the-art deep learning methods can be used for accurate and efficient monitoring in audio.

  12. Long term survival following the detection of circulating tumour cells in head and neck squamous cell carcinoma

    International Nuclear Information System (INIS)

    Winter, Stuart C; Stephenson, Sally-Anne; Subramaniam, Selva K; Paleri, Vinidh; Ha, Kien; Marnane, Conor; Krishnan, Suren; Rees, Guy

    2009-01-01

    Techniques for detecting circulating tumor cells in the peripheral blood of patients with head and neck cancers may identify individuals likely to benefit from early systemic treatment. Reconstruction experiments were used to optimise immunomagnetic enrichment and RT-PCR detection of circulating tumor cells using four markers (ELF3, CK19, EGFR and EphB4). This method was then tested in a pilot study using samples from 16 patients with advanced head and neck carcinomas. Seven patients were positive for circulating tumour cells both prior to and after surgery, 4 patients were positive prior to but not after surgery, 3 patients were positive after but not prior to surgery and 2 patients were negative. Two patients tested positive for circulating cells but there was no other evidence of tumor spread. Given this patient cohort had mostly advanced disease, as expected the detection of circulating tumour cells was not associated with significant differences in overall or disease free survival. For the first time, we show that almost all patients with advanced head and neck cancers have circulating cells at the time of surgery. The clinical application of techniques for detection of spreading disease, such as the immunomagnetic enrichment RT-PCR analysis used in this study, should be explored further

  13. The UW 21/123 monoclonal antibody in the radioimmunological detection of tumour tissue in the head and neck region

    International Nuclear Information System (INIS)

    Mueller, N.

    1987-01-01

    When incorporated in a radioimmunoassay the UW 21/123 the monoclonal antibody permits the diagnosis of certain squamous cell carcinoma of the cephalocervical region and is particularly reliable in the detection laryngeal carcinomas. It even permits the assessment of tumour cells that are not yet fully developed and thus still escape histological detection. (MBC) [de

  14. Life history, immunity, Peto's paradox and tumours in birds.

    Science.gov (United States)

    Møller, A P; Erritzøe, J; Soler, J J

    2017-05-01

    Cancer and tumours may evolve in response to life-history trade-offs between growth and duration of development on one hand, and between growth and maintenance of immune function on the other. Here, we tested whether (i) bird species with slow developmental rates for their body size experience low incidence of tumours because slow development allows for detection of rapid proliferation of cell lineages. We also test whether (ii) species with stronger immune response during development are more efficient at detecting tumour cells and hence suffer lower incidence of tumours. Finally, we tested Peto's paradox, that there is a positive relationship between tumour incidence and body mass. We used information on developmental rates and body mass from the literature and of tumour incidence (8468 birds) and size of the bursa of Fabricius for 7659 birds brought to a taxidermist in Denmark. We found evidence of the expected negative relationship between incidence of tumours and developmental rates and immunity after controlling for the positive association between tumour incidence and body size. These results suggest that evolution has modified the incidence of tumours in response to life history and that Peto's paradox may be explained by covariation between body mass, developmental rates and immunity. © 2017 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2017 European Society For Evolutionary Biology.

  15. Towards the optimisation of acoustic fields for ablative therapies of tumours in the upper abdomen

    International Nuclear Information System (INIS)

    Gélat, P; Ter Haar, G; Saffari, N

    2013-01-01

    The efficacy of high intensity focused ultrasound (HIFU) for the non-invasive treatment of cancer has been demonstrated for a range of different cancers including those of the liver, kidney, prostate and breast. As a non-invasive focused therapy, HIFU offers considerable advantages over other techniques such as chemotherapy and surgical resection, in terms of its non-invasiveness and low risk of harmful side effects. There is, however, a number of significant challenges which currently hinder its widespread clinical application. One of these challenges is the need to transmit sufficient energy through the ribcage to induce tissue necrosis at the required foci whilst minimising the formation of side lobes and sparing healthy tissue. Ribs both absorb and reflect ultrasound strongly. As such, a common side effect of focusing ultrasound in regions located behind the rib cage is the overheating of bone and surrounding tissue, which can lead to skin burns. Successful treatment of a patient with tumours in the upper abdomen therefore requires a thorough understanding of the way acoustic and thermal energy are deposited. This is likely to rely on a treatment planning procedure in which optimal source velocity distributions are obtained so as to maximise a dose quantity at the treatment sites, whilst ensuring that this quantity does not exceed a specified threshold at other field locations, particularly on the surface of the ribs. Previously, a boundary element approach based on a Generalised Minimal Residual (GMRES) implementation of the Burton-Miller formulation was developed to predict the field of a multi-element HIFU array scattered by human ribs, the topology of which was obtained from CT scan data [1]. This work describes the reformulation of the boundary element equations as a least-squares minimisation problem with non-linear constraints. The methodology was subsequently tested at an excitation frequency of 100 kHz on a spherical multi-element array in the presence

  16. Towards the optimisation of acoustic fields for ablative therapies of tumours in the upper abdomen

    Science.gov (United States)

    Gélat, P.; ter Haar, G.; Saffari, N.

    2013-08-01

    The efficacy of high intensity focused ultrasound (HIFU) for the non-invasive treatment of cancer has been demonstrated for a range of different cancers including those of the liver, kidney, prostate and breast. As a non-invasive focused therapy, HIFU offers considerable advantages over other techniques such as chemotherapy and surgical resection, in terms of its non-invasiveness and low risk of harmful side effects. There is, however, a number of significant challenges which currently hinder its widespread clinical application. One of these challenges is the need to transmit sufficient energy through the ribcage to induce tissue necrosis at the required foci whilst minimising the formation of side lobes and sparing healthy tissue. Ribs both absorb and reflect ultrasound strongly. As such, a common side effect of focusing ultrasound in regions located behind the rib cage is the overheating of bone and surrounding tissue, which can lead to skin burns. Successful treatment of a patient with tumours in the upper abdomen therefore requires a thorough understanding of the way acoustic and thermal energy are deposited. This is likely to rely on a treatment planning procedure in which optimal source velocity distributions are obtained so as to maximise a dose quantity at the treatment sites, whilst ensuring that this quantity does not exceed a specified threshold at other field locations, particularly on the surface of the ribs. Previously, a boundary element approach based on a Generalised Minimal Residual (GMRES) implementation of the Burton-Miller formulation was developed to predict the field of a multi-element HIFU array scattered by human ribs, the topology of which was obtained from CT scan data [1]. This work describes the reformulation of the boundary element equations as a least-squares minimisation problem with non-linear constraints. The methodology was subsequently tested at an excitation frequency of 100 kHz on a spherical multi-element array in the presence

  17. Detection of steam leaks into sodium in fast reactor steam generators by acoustic techniques - An overview of Indian programme

    International Nuclear Information System (INIS)

    Prabhakar, R.; Vyjayanthi, R.K.; Kale, R.D.

    1990-01-01

    Realising the potential of acoustic leak detection technique, an experimental programme was initiated a few years back at Indira Gandhi Centre for Atomic Research (IGCAR) to develop this technique. The first phase of this programme consists of experiments to measure background noise characteristics on the steam generator modules of the 40 MW (thermal) Fast Breeder Test Reactor (FBTR) at Kalpakkam and experiments to establish leak noise characteristics with the help of a leak simulation set up. By subjecting the measured data from these experiments to signal analysis techniques, a criterion for acoustic leak detection for FBTR steam generator will be evolved. Second phase of this programme will be devoted to developing an acoustic leak detection system suitable for installation in the 500 MWe Prototype Fast Breeder Reactor (PFBR). This paper discusses the first phase of the experimental programme, results obtained from measurements carried out on FBTR steam generators and results obtained from leak simulation experiments. Acoustic leak detection system being considered for PFBR is also briefly described. 4 refs, 8 figs, 1 tab

  18. Study on Leak Detection of the Pipeline System by Acoustic Emission

    International Nuclear Information System (INIS)

    Yoon, D. J.; Kim, C. J.

    1987-01-01

    Leak detection testing for the pipeline system was performed by the acoustic emission method. It was found that the detected signal spectrum was influenced by the frequency response of sensors and pressure changes. AE parameters and frequency spectrum distributions were used to analyze the leak signals. The slope rise time of AE parameters were the important factors for distinguishing leak signals. The amplitude of leak signal was more affected by the changes of leak, rate and pressure than those of leak type

  19. Molecular pathology of bone tumours: diagnostic implications.

    Science.gov (United States)

    Puls, Florian; Niblett, Angela J; Mangham, D Chas

    2014-03-01

    Alongside histomorphology and immunohistochemistry, molecular pathology is now established as one of the cornerstones in the tissue diagnosis of bone tumours. We describe the principal molecular pathological techniques employed, and each of the bone tumour entities where their identified characteristic molecular pathological changes can be detected to support and confirm the suspected histological diagnosis. Tumours discussed include fibrous dysplasia, classical and subtype osteosarcomas, central and surface cartilaginous tumours, Ewing's sarcoma, vascular tumours, aneurysmal bone cyst, chordoma, myoepithelioma, and angiomatoid fibrous histiocytoma. This is a rapidly evolving field with discoveries occurring every few months, and some of the newer entities (the Ewing's-like sarcomas), which are principally identified by their molecular pathology characteristics, are discussed. © 2013 John Wiley & Sons Ltd.

  20. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    OpenAIRE

    Marchevsky, M.; Wang, X.; Sabbi, G.; Prestemon, S.

    2014-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb3Sn quadrupole HQ01 [...

  1. Development of acoustic particle detector

    International Nuclear Information System (INIS)

    Matsuyama, Tadayoshi; Hinode, Fujio; Konno, Osamu

    1999-01-01

    To detect acoustic sign from electron, determination of acoustic radiation from high energy electron and detector were studied. When charge particles pass through medium, energy loss generates local expansion and contraction of medium and pressure compression wave. We need caustic element with 10 -5 Pa the minimum acoustic receive sensitivity and from 10 to 100 kHz frequency sensitivity characteristic. Elements were made by Low-Q materials, piezoelectric materials (PZT). Various sharp of elements were constructed and measured. 50 mm spherical element showed 38 m V/Pa, the best sensitivity. Our developed acoustic element could detect acoustic radiation generated by electron beam from accelerator. The wave sharp detected proved the same as bipolar wave, which was given theoretically. The pressure generated by beam was proportional to the energy loss E. 200 MeV electron beam existed about 95% particles on the incident axis. So that acoustic detector on the axis proved to detect sound wave generated on the beam axis. (S.Y.)

  2. Optimised Pre-Analytical Methods Improve KRAS Mutation Detection in Circulating Tumour DNA (ctDNA) from Patients with Non-Small Cell Lung Cancer (NSCLC)

    Science.gov (United States)

    Sherwood, James L.; Corcoran, Claire; Brown, Helen; Sharpe, Alan D.; Musilova, Milena; Kohlmann, Alexander

    2016-01-01

    Introduction Non-invasive mutation testing using circulating tumour DNA (ctDNA) is an attractive premise. This could enable patients without available tumour sample to access more treatment options. Materials & Methods Peripheral blood and matched tumours were analysed from 45 NSCLC patients. We investigated the impact of pre-analytical variables on DNA yield and/or KRAS mutation detection: sample collection tube type, incubation time, centrifugation steps, plasma input volume and DNA extraction kits. Results 2 hr incubation time and double plasma centrifugation (2000 x g) reduced overall DNA yield resulting in lowered levels of contaminating genomic DNA (gDNA). Reduced “contamination” and increased KRAS mutation detection was observed using cell-free DNA Blood Collection Tubes (cfDNA BCT) (Streck), after 72 hrs following blood draw compared to EDTA tubes. Plasma input volume and use of different DNA extraction kits impacted DNA yield. Conclusion This study demonstrated that successful ctDNA recovery for mutation detection in NSCLC is dependent on pre-analytical steps. Development of standardised methods for the detection of KRAS mutations from ctDNA specimens is recommended to minimise the impact of pre-analytical steps on mutation detection rates. Where rapid sample processing is not possible the use of cfDNA BCT tubes would be advantageous. PMID:26918901

  3. Optimised Pre-Analytical Methods Improve KRAS Mutation Detection in Circulating Tumour DNA (ctDNA from Patients with Non-Small Cell Lung Cancer (NSCLC.

    Directory of Open Access Journals (Sweden)

    James L Sherwood

    Full Text Available Non-invasive mutation testing using circulating tumour DNA (ctDNA is an attractive premise. This could enable patients without available tumour sample to access more treatment options.Peripheral blood and matched tumours were analysed from 45 NSCLC patients. We investigated the impact of pre-analytical variables on DNA yield and/or KRAS mutation detection: sample collection tube type, incubation time, centrifugation steps, plasma input volume and DNA extraction kits.2 hr incubation time and double plasma centrifugation (2000 x g reduced overall DNA yield resulting in lowered levels of contaminating genomic DNA (gDNA. Reduced "contamination" and increased KRAS mutation detection was observed using cell-free DNA Blood Collection Tubes (cfDNA BCT (Streck, after 72 hrs following blood draw compared to EDTA tubes. Plasma input volume and use of different DNA extraction kits impacted DNA yield.This study demonstrated that successful ctDNA recovery for mutation detection in NSCLC is dependent on pre-analytical steps. Development of standardised methods for the detection of KRAS mutations from ctDNA specimens is recommended to minimise the impact of pre-analytical steps on mutation detection rates. Where rapid sample processing is not possible the use of cfDNA BCT tubes would be advantageous.

  4. Mobile phones and head tumours. The discrepancies in cause-effect relationships in the epidemiological studies - how do they arise?

    Directory of Open Access Journals (Sweden)

    Gennaro Valerio

    2011-06-01

    Full Text Available Abstract Background Whether or not there is a relationship between use of mobile phones (analogue and digital cellulars, and cordless and head tumour risk (brain tumours, acoustic neuromas, and salivary gland tumours is still a matter of debate; progress requires a critical analysis of the methodological elements necessary for an impartial evaluation of contradictory studies. Methods A close examination of the protocols and results from all case-control and cohort studies, pooled- and meta-analyses on head tumour risk for mobile phone users was carried out, and for each study the elements necessary for evaluating its reliability were identified. In addition, new meta-analyses of the literature data were undertaken. These were limited to subjects with mobile phone latency time compatible with the progression of the examined tumours, and with analysis of the laterality of head tumour localisation corresponding to the habitual laterality of mobile phone use. Results Blind protocols, free from errors, bias, and financial conditioning factors, give positive results that reveal a cause-effect relationship between long-term mobile phone use or latency and statistically significant increase of ipsilateral head tumour risk, with biological plausibility. Non-blind protocols, which instead are affected by errors, bias, and financial conditioning factors, give negative results with systematic underestimate of such risk. However, also in these studies a statistically significant increase in risk of ipsilateral head tumours is quite common after more than 10 years of mobile phone use or latency. The meta-analyses, our included, examining only data on ipsilateral tumours in subjects using mobile phones since or for at least 10 years, show large and statistically significant increases in risk of ipsilateral brain gliomas and acoustic neuromas. Conclusions Our analysis of the literature studies and of the results from meta-analyses of the significant data alone

  5. A low molecular weight zinc2+-dipicolylamine-based probe detects apoptosis during tumour treatment better than an annexin V-based probe

    International Nuclear Information System (INIS)

    Palmowski, Karin; Rix, Anne; Lederle, Wiltrud; Kiessling, Fabian; Behrendt, Florian F.; Mottaghy, Felix M.; Gray, Brian D.; Pak, Koon Y.; Palmowski, Moritz

    2014-01-01

    Molecular imaging of apoptosis is frequently discussed for monitoring cancer therapies. Here, we compare the low molecular weight phosphatidylserine-targeting ligand zinc 2+ -dipicolylamine (Zn 2+ -DPA) with the established but reasonably larger protein annexin V. Molecular apoptosis imaging with the fluorescently labelled probes annexin V (750 nm, 36 kDa) and Zn 2+ -DPA (794 nm, 1.84 kDa) was performed in tumour-bearing mice (A431). Three animal groups were investigated: untreated controls and treated tumours after 1 or 4 days of anti-angiogenic therapy (SU11248). Additionally, μPET with 18 F-FDG was performed. Imaging data were displayed as tumour-to-muscle ratio (TMR) and validated by quantitative immunohistochemistry. Compared with untreated control tumours, TUNEL staining indicated significant apoptosis after 1 day (P 2+ -DPA uptake increased significantly after 1 day (P 2+ -DPA, 18 F-FDG tumour uptake decreased significantly at days 1 (P 2+ -DPA than with the annexin V-based probe. Additionally, significant treatment effects were detectable as early using Zn 2+ -DPA as with measurements of the glucose metabolism using 18 F-FDG. (orig.)

  6. YIP Expansion: Ocean Basin Impact of Ambient Noise on Marine Mammal Detectability, Distribution, and Acoustic Communication

    Science.gov (United States)

    2015-09-30

    Marine Mammal Detectability, Distribution, and Acoustic Communication Jennifer L. Miksis-Olds Applied Research Laboratory The Pennsylvania State...relatively stereotyped calls, commonly considered types of automatic detection include spectrogram correlation and matched filtering. Spectrogram

  7. Acoustic occurrence detection of a newly recorded Indo-Pacific humpback dolphin population in waters southwest of Hainan Island, China.

    Science.gov (United States)

    Dong, Lijun; Liu, Mingming; Dong, Jianchen; Li, Songhai

    2017-11-01

    In 2014, Indo-Pacific humpback dolphins were recorded for the first time in waters southwest of Hainan Island, China. In this paper, the temporal occurrence of Indo-Pacific humpback dolphins in this region was detected by stationary passive acoustic monitoring. During the 130-day observation period (from January to July 2016), 1969 click trains produced by Indo-Pacific humpback dolphins were identified, and 262 ten-minute recording bins contained echolocation click trains of dolphins, of which 70.9% were at night and 29.1% were during the day. A diurnal rhythm with a nighttime peak in acoustic detections was found. Passive acoustic detections indicated that the Indo-Pacific humpback dolphins frequently occurred in this area and were detected mainly at night. This information may be relevant to conservation efforts for these dolphins in the near future.

  8. Mach-Zehnder interferometric photonic crystal fiber for low acoustic frequency detections

    Energy Technology Data Exchange (ETDEWEB)

    Pawar, Dnyandeo; Rao, Ch. N.; Kale, S. N., E-mail: sangeetakale2004@gmail.com [Department of Applied Physics, Defence Institute of Advanced Technology (DU), Girinagar, Pune 411 025, Maharashtra (India); Choubey, Ravi Kant [Department of Applied Physics, Amity Institute of Applied Sciences, Amity University, Noida 201 313 (India)

    2016-01-25

    Low frequency under-water acoustic signal detections are challenging, especially for marine applications. A Mach-Zehnder interferometric hydrophone is demonstrated using polarization-maintaining photonic-crystal-fiber (PM-PCF), spliced between two single-mode-fibers, operated at 1550 nm source. These data are compared with standard hydrophone, single-mode and multimode fiber. The PM-PCF sensor shows the highest response with a power shift (2.32 dBm) and a wavelength shift (392.8 pm) at 200 Hz. High birefringence values and the effect of the imparted acoustic pressure on this fiber, introducing the difference between the fast and slow axis changes, owing to the phase change in the propagation waves, demonstrate the strain-optic properties of the sensor.

  9. Acoustic Leak Detection Testing Using KAERI Sodium-Water Reaction Signals for a SFR Steam Generator

    International Nuclear Information System (INIS)

    Kim, Tae-Joon; Jeong, Ji-Young; Kim, Jong-Man; Kim, Byung-Ho; Hahn, Do-Hee; Yugay, Valeriy S.

    2009-01-01

    The results of an experimental study of water in a sodium leak noise spectrum formation at 0.004-0.54 g/sec, various rates of water into a sodium leak, smaller than 1.0 g/sec, are presented. We focused on studying a micro leak detection with an increasing rate of water into sodium. On the basis of the experimental leak noise data manufactured in KAERI the simple dependency of an acoustic signal level from the rate of a micro and small leak at different frequency bands is presented to understand the principal analysis for the development of an acoustic leak detection methodology used in a K- 600 steam generator

  10. Experimental study on the detection of free fluids and gases in waste packages by acoustic methods

    International Nuclear Information System (INIS)

    Eisenblaetter, J.; Schaefer, P.; Weib, R.

    1992-01-01

    The objective of the project was to evaluate the potential and the limits of various nondestructive methods for testing the contents of 200-litre drums filled with radioactive waste. The following test problems were to be studied: 1. Detection of free water on the surface of the waste matrix (concrete); 2. Determination of the waste matrix level; 3. Determination of internal gas pressure. The following methods were found to be suitable: For Test problem 1: Measurement of Lamb wave attenuation, Acoustic impedance measurement (AIM) and Analysis of swash sound; For Test problem 2: Acoustic impedance measurement (AIM) and Measurement of Lamb wave attenuation; For Test problem 3: A method of pressure compensation and Analysis of cover resonances after striking the cover. It was not possible, however, to detect the concrete level by localisation of friction points using acoustic emission methods. 53 figs

  11. Leak detection and localization system through acoustics; Sistema de deteccao e localizacao de vazamentos por acustica

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Julio [Aselco Automacao, Sao Paulo, SP (Brazil)

    2003-07-01

    Acoustic Leak Detection Systems (ALDS) are used on both liquid and gas pipelines as well as multi-phase flow pipelines to detect leaks quickly and provide a means of limiting product loss. The real-time acoustic signal is continuously compared against signature leak profiles for the particular operating and geometric conditions. These profiles were developed from a database established from over 20 years of experimental and field leak tests. This technique not only drastically reduces the false alarm rate, but also significantly improves the sensitivity and leak location accuracy. This system will also detect leaks with shut-in flow (zero flow rate in the pipeline). With the use of GPS (Global Positioning System) it not only improves leak location accuracy, but also allows for continuous leak detection during the loss of communications. (author)

  12. Radiation acoustics and its applications

    International Nuclear Information System (INIS)

    Lyamshev, L.M.

    1992-01-01

    Radiation acoustics is a new branch of acoustics, developing on the boundary of acoustics, nuclear physics, elementary particles and high-energy physics. Its fundamentals are laying in the research of acoustical effects due to the interaction of penetrating radiation with matter. The study of radiation-acoustical effects leads to the new opportunities in the penetration radiation research (acoustical detection, radiation-acoustical dosimetry), study of the physical parameters of matter, in a solution of some applied problems of nondestructive testing, and also for the radiation-acoustical influence on physical and chemical structure of the matter. Results of theoretical and experimental investigations are given. Different mechanisms of the sound generation by penetrating radiation of liquids and solids are considered. Some applications - the radiation acoustical microscopy and visualisation, the acoustical detection of high energy X-ray particles and possibility of using of high energy neutrino beams in geoacoustics - are discussed

  13. Tube leak detection device and acoustic sensor support device for moisture separating heater

    International Nuclear Information System (INIS)

    Miyabe, Keisuke; Kobayashi, Takefumi.

    1995-01-01

    The device of the present invention comprises an acoustic sensor which detects leak sounds when leak occurs in a heating tube of a moisture separating heater incorporated into a plant, a threshold value memory and switching mechanism containing each of threshold values on every power of a plant, and a leak judging mechanism for judging presence or absence of leaks by comparing a selected threshold value and signals given from the acoustic sensor. Background noises changing currently during operation of a steam turbine plant are compared with a threshold value greater than the background noises in the leak judging mechanism, and they are judged as 'no leak' so as not to recognize them as 'presence of tube leak'. Output values from the acoustic sensor are obtained on every frequency component, and standard frequency spectra are selected by turbine load corresponding signals using a standard spectra memory and switching mechanism. They are sent to a leak judging mechanism to analyze the acoustic signals using a frequency analyzer and compare them with the frequency spectral thereby judging leaks. (N.H.)

  14. Nuclear medicine procedures to diagnose endocrine pancreatic tumours

    International Nuclear Information System (INIS)

    Bares, R.; Besenfelder, H.; Eschmann, S.M.; Pfannenberg, C.

    2003-01-01

    The typical clinical features of endocrine pancreatic tumours are either symptoms caused by excessive hormone production or progressive tumour growth. In several prospective studies it has been shown that somatostatin receptor scintigraphy is the most accurate imaging technique currently available to detect endocrine pancreatic tumours. Therefore it should be used whenever curative surgical treatment appears to be feasible. Furthermore it should be applied if a radionuclide treatment of inoperable tumours is considered. In this situation scintigraphy with 123 I-mIBG might be useful, too. Future developments include the use of PET with labelled somatostatin analogues or DOPA derivatives as well as image fusion techniques to optimize preoperative tumour localization. (orig.) [de

  15. Automated valve fault detection based on acoustic emission parameters and support vector machine

    Directory of Open Access Journals (Sweden)

    Salah M. Ali

    2018-03-01

    Full Text Available Reciprocating compressors are one of the most used types of compressors with wide applications in industry. The most common failure in reciprocating compressors is always related to the valves. Therefore, a reliable condition monitoring method is required to avoid the unplanned shutdown in this category of machines. Acoustic emission (AE technique is one of the effective recent methods in the field of valve condition monitoring. However, a major challenge is related to the analysis of AE signal which perhaps only depends on the experience and knowledge of technicians. This paper proposes automated fault detection method using support vector machine (SVM and AE parameters in an attempt to reduce human intervention in the process. Experiments were conducted on a single stage reciprocating air compressor by combining healthy and faulty valve conditions to acquire the AE signals. Valve functioning was identified through AE waveform analysis. SVM faults detection model was subsequently devised and validated based on training and testing samples respectively. The results demonstrated automatic valve fault detection model with accuracy exceeding 98%. It is believed that valve faults can be detected efficiently without human intervention by employing the proposed model for a single stage reciprocating compressor. Keywords: Condition monitoring, Faults detection, Signal analysis, Acoustic emission, Support vector machine

  16. Acoustic emission

    International Nuclear Information System (INIS)

    Straus, A.; Lopez Pumarega, M.I.; Di Gaetano, J.O.; D'Atellis, C.E.; Ruzzante, J.E.

    1990-01-01

    This paper is related to our activities on acoustic emission (A.E.). The work is made with different materials: metals and fibre reinforced plastics. At present, acoustic emission transducers are being developed for low and high temperature. A test to detect electrical discharges in electrical transformers was performed. Our experience in industrial tests to detect cracks or failures in tanks or tubes is also described. The use of A.E. for leak detection is considered. Works on pattern recognition of A.E. signals are also being performed. (Author)

  17. Comparison between air CT and MRI in the detection of small acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Kamei, Tetsuya; Nakashima, Aiko; Seto, Hikaru; Kakishita, Masao

    1989-02-01

    Air CT proved useful in yielding images of acoustic tumors as an air filling defect in 11 (24%) of 46 patients. Six of the 11 tumors were small ones of less than 1 cm in diameter. Air CT was also able to exclude an intracanalicular tumor in 29 patients (63%). MRI was performed for comparison in eight patients (nine tumors) already diagnosed by air CT as having an acoustic tumor. MRI detected eight (89%) of nine tumors. A false negative result on MRI was obtained only in one intracanalicular tumor (4.3 mm in size). This was considered to be attributable to limitations of spatial resolution including the wide slice thickness. A protocol for radiological investigation and management of patients whose clinical symptoms and/or audiovestibular examination are highly indicative of acoustic tumor is proposed and discussed. (author).

  18. Comparison between air CT and MRI in the detection of small acoustic neurinomas

    International Nuclear Information System (INIS)

    Kamei, Tetsuya; Nakashima, Aiko; Seto, Hikaru; Kakishita, Masao

    1989-01-01

    Air CT proved useful in yielding images of acoustic tumors as an air filling defect in 11 (24%) of 46 patients. Six of the 11 tumors were small ones of less than 1 cm in diameter. Air CT was also able to exclude an intracanalicular tumor in 29 patients (63%). MRI was performed for comparison in eight patients (nine tumors) already diagnosed by air CT as having an acoustic tumor. MRI detected eight (89%) of nine tumors. A false negative result on MRI was obtained only in one intracanalicular tumor (4.3 mm in size). This was considered to be attributable to limitations of spatial resolution including the wide slice thickness. A protocol for radiological investigation and management of patients whose clinical symptoms and/or audiovestibular examination are highly indicative of acoustic tumor is proposed and discussed. (author)

  19. Acoustic feedwater heater leak detection: Industry application of low ampersand high frequency detection increases response and reliability

    International Nuclear Information System (INIS)

    Woyshner, W.S.; Bryson, T.; Robertson, M.O.

    1993-01-01

    The Electric Power Research Institute has sponsored research associated with acoustic Feedwater Heater Leak Detection since the early 1980s. Results indicate that this technology is economically beneficial and dependable. Recent research work has employed acoustic sensors and signal conditioning with wider frequency range response and background noise elimination techniques to provide increased accuracy and dependability. Dual frequency sensors have been applied at a few facilities to provide information on this application of dual frequency response. Sensor mounting methods and attenuation due to various mounting configurations are more conclusively understood. These are depicted and discussed in detail. The significance of trending certain plant parameters such as heat cycle flows, heater vent and drain valve position, proper relief valve operation, etc. is also addressed. Test data were collected at various facilities to monitor the effect of varying several related operational parameters. A group of FWHLD Users have been involved from the inception of the project and reports on their latest successes and failures, along with various data depicting early detection of FWHLD tube leaks, will be included. 3 refs., 12 figs., 1 tab

  20. Renal angiomyoadenomatous tumour: Imaging features

    Science.gov (United States)

    Sahni, V. Anik; Hirsch, Michelle S.; Silverman, Stuart G.

    2012-01-01

    Renal angiomyoadenomatous tumour is a rare, recently described neoplasm with a distinctive histological appearance. Although reported in the pathology literature, to our knowledge, no prior reports have described its imaging appearance. We describe the computed tomography and magnetic resonance imaging features of an incidentally detected renal angiomyoadenomatous tumour that appeared as a well-marginated, solid T2-hypointense enhancing mass, in a 50-year-old woman. It is indistinguishable from a variety of benign and malignant renal neoplasms. PMID:23093565

  1. Surface acoustic wave sensors with Graphene/PANI nanocomposites for nitric oxide detection

    Science.gov (United States)

    Wang, Beibei; Zheng, Lei; Zhou, Lingling

    2017-12-01

    Surface acoustic wave sensors with grapheme/PANI nanocomposite sensitive films for detecting nitric oxide (NO) were fabricated and experimentally studied. Morphological characterization and functionalization of the sensing material were explored using SEM and FTIR, respectively. The study of sensor response compared film sensitivity, response time, reversibility, and limit of detection for nanocomposite films, pure grapheme and pure PANI to the detection of NO. The response and recovery times were 40s and 20s when detecting 4ppm NO, respectively. The frequency response was discovered to be linear in the NO concentration range 1-50 ppm. The nanocomposite sensors had improved sensitivities compared to the polymer devices, and better response times.

  2. Tumour-associated microglia/macrophages predict poor prognosis in high-grade gliomas and correlate with an aggressive tumour subtype

    DEFF Research Database (Denmark)

    Sørensen, M D; Dahlrot, R H; Boldt, H B

    2018-01-01

    AIMS: Glioblastomas are highly aggressive and treatment resistant. Increasing evidence suggests that tumour-associated macrophages/microglia (TAMs) facilitate tumour progression by acquiring a M2-like phenotype. Our objective was to investigate the prognostic value of TAMs in gliomas using...... automated quantitative double immunofluorescence. METHODS: Samples from 240 patients with primary glioma were stained with antibodies against ionized calcium-binding adaptor molecule-1 (IBA-1) and cluster of differentiation 204 (CD204) to detect TAMs and M2-like TAMs. The expression levels were quantified...... by software-based classifiers. The associations between TAMs, gemistocytic cells and glioblastoma subtype were examined with immuno- and haematoxylin-eosin stainings. Three tissue arrays containing glioblastoma specimens were included to study IBA-1/CD204 levels in central tumour and tumour periphery...

  3. Magnetic resonance spectroscopy metabolite profiles predict survival in paediatric brain tumours.

    Science.gov (United States)

    Wilson, Martin; Cummins, Carole L; Macpherson, Lesley; Sun, Yu; Natarajan, Kal; Grundy, Richard G; Arvanitis, Theodoros N; Kauppinen, Risto A; Peet, Andrew C

    2013-01-01

    Brain tumours cause the highest mortality and morbidity rate of all childhood tumour groups and new methods are required to improve clinical management. (1)H magnetic resonance spectroscopy (MRS) allows non-invasive concentration measurements of small molecules present in tumour tissue, providing clinically useful imaging biomarkers. The primary aim of this study was to investigate whether MRS detectable molecules can predict the survival of paediatric brain tumour patients. Short echo time (30ms) single voxel (1)H MRS was performed on children attending Birmingham Children's Hospital with a suspected brain tumour and 115 patients were included in the survival analysis. Patients were followed-up for a median period of 35 months and Cox-Regression was used to establish the prognostic value of individual MRS detectable molecules. A multivariate model of survival was also investigated to improve prognostic power. Lipids and scyllo-inositol predicted poor survival whilst glutamine and N-acetyl aspartate predicted improved survival (pmodel of survival based on three MRS biomarkers predicted survival with a similar accuracy to histologic grading (p5e-5). A negative correlation between lipids and glutamine was found, suggesting a functional link between these molecules. MRS detectable biomolecules have been identified that predict survival of paediatric brain tumour patients across a range of tumour types. The evaluation of these biomarkers in large prospective studies of specific tumour types should be undertaken. The correlation between lipids and glutamine provides new insight into paediatric brain tumour metabolism that may present novel targets for therapy. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. The retinoblastoma gene is frequently altered leading to loss of expression in primary breast tumours.

    Science.gov (United States)

    Varley, J M; Armour, J; Swallow, J E; Jeffreys, A J; Ponder, B A; T'Ang, A; Fung, Y K; Brammar, W J; Walker, R A

    1989-06-01

    We have analysed the organisation of the retinoblastoma (RB1) gene in 77 primary breast carcinomas, in metastatic tissue derived from 16 of those primary tumours, and in a variety of benign breast lesions. Expression of RB1 was also assessed in most samples by immunohistochemical detection of the RB1 protein in tissue sections. Structural abnormalities to RB1 were detected in DNA from 15/77 (19%) of primary breast carcinomas examined. Where DNA was available from metastatic tissue derived from such primary tumours, the same aberration could be detected. No alterations were seen in benign breast lesions. 16/56 (29%) of tumours examined for expression by immunohistochemical methods showed a proportion of tumour cells to be completely negative for the RB1 protein. All tumours in which a structural alteration to RB1 was detected had a proportion of negative cells, except for one case where all cells were positive. Several primary tumour samples were identified where there was no detectable structural change to the gene, but there was loss of expression in some tumour cells. The data presented here demonstrate that changes to the RB1 gene leading to loss of expression of both alleles are frequent in primary human breast tumours.

  5. Guided acoustic wave inspection system

    Science.gov (United States)

    Chinn, Diane J.

    2004-10-05

    A system for inspecting a conduit for undesirable characteristics. A transducer system induces guided acoustic waves onto said conduit. The transducer system detects the undesirable characteristics of the conduit by receiving guided acoustic waves that contain information about the undesirable characteristics. The conduit has at least two sides and the transducer system utilizes flexural modes of propagation to provide inspection using access from only the one side of the conduit. Cracking is detected with pulse-echo testing using one transducer to both send and receive the guided acoustic waves. Thinning is detected in through-transmission testing where one transducer sends and another transducer receives the guided acoustic waves.

  6. Detecting temporal changes in acoustic scenes: The variable benefit of selective attention.

    Science.gov (United States)

    Demany, Laurent; Bayle, Yann; Puginier, Emilie; Semal, Catherine

    2017-09-01

    Four experiments investigated change detection in acoustic scenes consisting of a sum of five amplitude-modulated pure tones. As the tones were about 0.7 octave apart and were amplitude-modulated with different frequencies (in the range 2-32 Hz), they were perceived as separate streams. Listeners had to detect a change in the frequency (experiments 1 and 2) or the shape (experiments 3 and 4) of the modulation of one of the five tones, in the presence of an informative cue orienting selective attention either before the scene (pre-cue) or after it (post-cue). The changes left intensity unchanged and were not detectable in the spectral (tonotopic) domain. Performance was much better with pre-cues than with post-cues. Thus, change deafness was manifest in the absence of an appropriate focusing of attention when the change occurred, even though the streams and the changes to be detected were acoustically very simple (in contrast to the conditions used in previous demonstrations of change deafness). In one case, the results were consistent with a model based on the assumption that change detection was possible if and only if attention was endogenously focused on a single tone. However, it was also found that changes resulting in a steepening of amplitude rises were to some extent able to draw attention exogenously. Change detection was not markedly facilitated when the change produced a discontinuity in the modulation domain, contrary to what could be expected from the perspective of predictive coding. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Shear horizontal surface acoustic wave microsensor for Class A viral and bacterial detection.

    Energy Technology Data Exchange (ETDEWEB)

    Branch, Darren W.; Huber, Dale L.; Brozik, Susan Marie; Edwards, Thayne L.

    2008-10-01

    The rapid autonomous detection of pathogenic microorganisms and bioagents by field deployable platforms is critical to human health and safety. To achieve a high level of sensitivity for fluidic detection applications, we have developed a 330 MHz Love wave acoustic biosensor on 36{sup o} YX Lithium Tantalate (LTO). Each die has four delay-line detection channels, permitting simultaneous measurement of multiple analytes or for parallel detection of single analyte containing samples. Crucial to our biosensor was the development of a transducer that excites the shear horizontal (SH) mode, through optimization of the transducer, minimizing propagation losses and reducing undesirable modes. Detection was achieved by comparing the reference phase of an input signal to the phase shift from the biosensor using an integrated electronic multi-readout system connected to a laptop computer or PDA. The Love wave acoustic arrays were centered at 330 MHz, shifting to 325-328 MHz after application of the silicon dioxide waveguides. The insertion loss was -6 dB with an out-of-band rejection of 35 dB. The amplitude and phase ripple were 2.5 dB p-p and 2-3{sup o} p-p, respectively. Time-domain gating confirmed propagation of the SH mode while showing suppression of the triple transit. Antigen capture and mass detection experiments demonstrate a sensitivity of 7.19 {+-} 0.74{sup o} mm{sup 2}/ng with a detection limit of 6.7 {+-} 0.40 pg/mm{sup 2} for each channel.

  8. Human cytomegalovirus tegument protein pp65 is detected in all intra- and extra-axial brain tumours independent of the tumour type or grade.

    Directory of Open Access Journals (Sweden)

    Sylwia Libard

    Full Text Available Human cytomegalovirus (HCMV has been indicated being a significant oncomodulator. Recent reports have suggested that an antiviral treatment alters the outcome of a glioblastoma. We analysed the performance of commercial HCMV-antibodies applying the immunohistochemical (IHC methods on brain sample obtained from a subject with a verified HCMV infection, on samples obtained from 14 control subjects, and on a tissue microarray block containing cores of various brain tumours. Based on these trials, we selected the best performing antibody and analysed a cohort of 417 extra- and intra-axial brain tumours such as gliomas, medulloblastomas, primary diffuse large B-cell lymphomas, and meningiomas. HCMV protein pp65 immunoreactivity was observed in all types of tumours analysed, and the IHC expression did not depend on the patient's age, gender, tumour type, or grade. The labelling pattern observed in the tumours differed from the labelling pattern observed in the tissue with an active HCMV infection. The HCMV protein was expressed in up to 90% of all the tumours investigated. Our results are in accordance with previous reports regarding the HCMV protein expression in glioblastomas and medulloblastomas. In addition, the HCMV protein expression was seen in primary brain lymphomas, low-grade gliomas, and in meningiomas. Our results indicate that the HCMV protein pp65 expression is common in intra- and extra-axial brain tumours. Thus, the assessment of the HCMV expression in tumours of various origins and pathologically altered tissue in conditions such as inflammation, infection, and even degeneration should certainly be facilitated.

  9. The possibilities of the detection of boiling in the reactor core on the basis of acoustic emission method

    International Nuclear Information System (INIS)

    Liska, J.

    1978-01-01

    A method is described of detecting the crisis of boiling in the core of PWR type reactors which may lead to fuel element failure. The method can be applied both in reactor development and operation. It is based on boiling detection by acoustic emission testing. The acoustic signal is measured by means of a piezoelectric transducer immersed in water or attached to one end of a waveguide immersed in water. Signals may be measured in either a wide frequency range or in a band approaching the transducer resonance frequency. This is selected such as to be outside the noise band. Experiments in an open water tank and in a water loop showed that under favourable conditions, the acoustic emission testing method was very sensitive, the intensity of acoustic signals was proportional to boiling intensity, and information contained in the emission spectrum shape was primarily of a qualitative nature. The method remains to be tested in an actual reactor where many spurious noise sources exist. (O.K.)

  10. An Acoustic-Based Method to Detect and Quantify the Effect of Exhalation into a Dry Powder Inhaler.

    Science.gov (United States)

    Holmes, Martin S; Seheult, Jansen N; O'Connell, Peter; D'Arcy, Shona; Ehrhardt, Carsten; Healy, Anne Marie; Costello, Richard W; Reilly, Richard B

    2015-08-01

    Dry powder inhaler (DPI) users frequently exhale into their inhaler mouthpiece before the inhalation step. This error in technique compromises the integrity of the drug and results in poor bronchodilation. This study investigated the effect of four exhalation factors (exhalation flow rate, distance from mouth to inhaler, exhalation duration, and relative air humidity) on dry powder dose delivery. Given that acoustic energy can be related to the factors associated with exhalation sounds, we then aimed to develop a method of identifying and quantifying this critical inhaler technique error using acoustic based methods. An in vitro test rig was developed to simulate this critical error. The effect of the four factors on subsequent drug delivery were investigated using multivariate regression models. In a further study we then used an acoustic monitoring device to unobtrusively record the sounds 22 asthmatic patients made whilst using a Diskus(™) DPI. Acoustic energy was employed to automatically detect and analyze exhalation events in the audio files. All exhalation factors had a statistically significant effect on drug delivery (pacoustic method detected exhalations with an accuracy of 89.1%. We were able to classify exhalations occurring 5 cm or less in the direction of the inhaler mouthpiece or recording device with a sensitivity of 72.2% and specificity of 85.7%. Exhaling into a DPI has a significant detrimental effect. Acoustic based methods can be employed to objectively detect and analyze exhalations during inhaler use, thus providing a method of remotely monitoring inhaler technique and providing personalized inhaler technique feedback.

  11. Imaging biomarkers in primary brain tumours

    Energy Technology Data Exchange (ETDEWEB)

    Lopci, Egesta; Chiti, Arturo [Humanitas Clinical and Research Center, Nuclear Medicine Department, Rozzano, MI (Italy); Franzese, Ciro; Navarria, Pierina; Scorsetti, Marta [Humanitas Clinical and Research Center, Radiosurgery and Radiotherapy, Rozzano, MI (Italy); Grimaldi, Marco [Humanitas Clinical and Research Center, Radiology, Rozzano, MI (Italy); Zucali, Paolo Andrea; Simonelli, Matteo [Humanitas Clinical and Research Center, Medical Oncology, Rozzano, MI (Italy); Bello, Lorenzo [Humanitas Clinical and Research Center, Neurosurgery, Rozzano, MI (Italy)

    2015-04-01

    We are getting used to referring to instrumentally detectable biological features in medical language as ''imaging biomarkers''. These two terms combined reflect the evolution of medical imaging during recent decades, and conceptually comprise the principle of noninvasive detection of internal processes that can become targets for supplementary therapeutic strategies. These targets in oncology include those biological pathways that are associated with several tumour features including independence from growth and growth-inhibitory signals, avoidance of apoptosis and immune system control, unlimited potential for replication, self-sufficiency in vascular supply and neoangiogenesis, acquired tissue invasiveness and metastatic diffusion. Concerning brain tumours, there have been major improvements in neurosurgical techniques and radiotherapy planning, and developments of novel target drugs, thus increasing the need for reproducible, noninvasive, quantitative imaging biomarkers. However, in this context, conventional radiological criteria may be inappropriate to determine the best therapeutic option and subsequently to assess response to therapy. Integration of molecular imaging for the evaluation of brain tumours has for this reason become necessary, and an important role in this setting is played by imaging biomarkers in PET and MRI. In the current review, we describe most relevant techniques and biomarkers used for imaging primary brain tumours in clinical practice, and discuss potential future developments from the experimental context. (orig.)

  12. Head Injury and Intracranial Pressure Monitor Using Ultrasonic and Low-Frequency Acoustic (ULFA) Detection

    National Research Council Canada - National Science Library

    Vo-Dinh, Tuan

    2001-01-01

    The main objective of this research project is the development of a non-invasive method and instrument for head injury detection and monitoring using a new approach based on ultrasonic and low-frequency acoustic (ULFA...

  13. Somatostatin receptor subtype expression in human thyroid tumours.

    Science.gov (United States)

    Klagge, A; Krause, K; Schierle, K; Steinert, F; Dralle, H; Fuhrer, D

    2010-04-01

    Somatostatin receptors (SSTR) are expressed in various endocrine tumours. The expression of SSTR at the tumour cell surface confers the possibility for diagnostic imaging and therapy of tumours using radiolabeled somatostatin analogues. The majority of currently available somatostatin analogues show a higher binding affinity for the SSTR2 subtype. To date, the precise expression pattern of the SSTR subtypes 1-5 in thyroid epithelial tumours remains to be determined. We investigated the mRNA expression of SSTR1-5 in benign and malignant epithelial thyroid tumours [20 cold thyroid nodules (CTNs), 20 toxic thyroid nodules (TTNs), 20 papillary, 20 follicular, and 5 anaplastic carcinomas (PTCs, FTCs, ATCs, respectively)] and compared them to normal surrounding thyroid tissues. Four out of five SSTR subtypes were detected in malignant thyroid tumours, benign neoplasia, and normal surrounding tissue with a predominant expression of SSTR2 and SSTR5, and a weak expression of SSTR1 and SSTR3. Weak SSTR4 mRNA expression was detected in some PTCs. Compared to normal thyroid tissue, SSTR2 was significantly upregulated in PTC and ATC. In addition significant upregulation of SSTR3 was found in PTC. SSTR5 mRNA expression was increased in PTC and FTC and significantly decreased in CTN and TTN compared to normal thyroid tissue. SSTR2 is the predominant subtype in thyroid epithelial tumours with a high expression pattern, in particular, in PTC . Perspectively, the expression of distinct SSTR in thyroid epithelial tumours might represent a promising avenue for diagnostics and therapy of advanced thyroid cancer with somatostatin analogues. Georg Thieme Verlag KG Stuttgart New York.

  14. Phase congruency map driven brain tumour segmentation

    Science.gov (United States)

    Szilágyi, Tünde; Brady, Michael; Berényi, Ervin

    2015-03-01

    Computer Aided Diagnostic (CAD) systems are already of proven value in healthcare, especially for surgical planning, nevertheless much remains to be done. Gliomas are the most common brain tumours (70%) in adults, with a survival time of just 2-3 months if detected at WHO grades III or higher. Such tumours are extremely variable, necessitating multi-modal Magnetic Resonance Images (MRI). The use of Gadolinium-based contrast agents is only relevant at later stages of the disease where it highlights the enhancing rim of the tumour. Currently, there is no single accepted method that can be used as a reference. There are three main challenges with such images: to decide whether there is tumour present and is so localize it; to construct a mask that separates healthy and diseased tissue; and to differentiate between the tumour core and the surrounding oedema. This paper presents two contributions. First, we develop tumour seed selection based on multiscale multi-modal texture feature vectors. Second, we develop a method based on a local phase congruency based feature map to drive level-set segmentation. The segmentations achieved with our method are more accurate than previously presented methods, particularly for challenging low grade tumours.

  15. Battlefield acoustics

    CERN Document Server

    Damarla, Thyagaraju

    2015-01-01

    This book presents all aspects of situational awareness in a battlefield using acoustic signals. It starts by presenting the science behind understanding and interpretation of sound signals. The book then goes on to provide various signal processing techniques used in acoustics to find the direction of sound source, localize gunfire, track vehicles, and detect people. The necessary mathematical background and various classification and fusion techniques are presented. The book contains majority of the things one would need to process acoustic signals for all aspects of situational awareness in one location. The book also presents array theory, which is pivotal in finding the direction of arrival of acoustic signals. In addition, the book presents techniques to fuse the information from multiple homogeneous/heterogeneous sensors for better detection. MATLAB code is provided for majority of the real application, which is a valuable resource in not only understanding the theory but readers, can also use the code...

  16. Comparison of spatial frequency domain features for the detection of side attack explosive ballistics in synthetic aperture acoustics

    Science.gov (United States)

    Dowdy, Josh; Anderson, Derek T.; Luke, Robert H.; Ball, John E.; Keller, James M.; Havens, Timothy C.

    2016-05-01

    Explosive hazards in current and former conflict zones are a threat to both military and civilian personnel. As a result, much effort has been dedicated to identifying automated algorithms and systems to detect these threats. However, robust detection is complicated due to factors like the varied composition and anatomy of such hazards. In order to solve this challenge, a number of platforms (vehicle-based, handheld, etc.) and sensors (infrared, ground penetrating radar, acoustics, etc.) are being explored. In this article, we investigate the detection of side attack explosive ballistics via a vehicle-mounted acoustic sensor. In particular, we explore three acoustic features, one in the time domain and two on synthetic aperture acoustic (SAA) beamformed imagery. The idea is to exploit the varying acoustic frequency profile of a target due to its unique geometry and material composition with respect to different viewing angles. The first two features build their angle specific frequency information using a highly constrained subset of the signal data and the last feature builds its frequency profile using all available signal data for a given region of interest (centered on the candidate target location). Performance is assessed in the context of receiver operating characteristic (ROC) curves on cross-validation experiments for data collected at a U.S. Army test site on different days with multiple target types and clutter. Our preliminary results are encouraging and indicate that the top performing feature is the unrolled two dimensional discrete Fourier transform (DFT) of SAA beamformed imagery.

  17. Detection and localization of leak of pipelines of RBMK reactor. Methods of processing of acoustic noise

    International Nuclear Information System (INIS)

    Tcherkaschov, Y.M.; Strelkov, B.P.; Chimanski, S.B.; Lebedev, V.I.; Belyanin, L.A.

    1997-01-01

    For realization of leak detection of input pipelines and output pipelines of RBMK reactor the method, based on detection and control of acoustic leak signals, was designed. In this report the review of methods of processing and analysis of acoustic noise is submitted. These methods were included in the software of the leak detection system and are used for the decision of the following problems: leak detection by method of sound pressure level in conditions of powerful background noise and strong attenuation of a signal; detection of a small leak in early stage by high-sensitivity correlation method; determination of a point of a sound source in conditions of strong reflection of a signal by a correlation method and sound pressure method; evaluation of leak size by the analysis of a sound level and point of a sound source. The work of considered techniques is illustrated on an example of test results of a fragment of the leak detection system. This test was executed on a Leningrad NPP, operated at power levels of 460, 700, 890 and 1000 MWe. 16 figs

  18. Gamma knife radiosurgery of acoustic neurinomas

    International Nuclear Information System (INIS)

    Bertalanffy, A.; Dietrich, W.; Aichholzer, M.; Kitz, K.; Heimberger, K.; Brix, R.

    2001-01-01

    The authors report on their series of 40 patients with 41 acoustic neurinomas (ACNs), including one patient with bilateral acoustic neurinomas suffering from neurofibromatosis type 2 (NF II) who were treated with the gamma knife unit at their institution between August 1992 and October 1995. Of these 41 tumours, 21 ACNs had been operated on before (l to 4 times), 20 ACNs were exclusively treated by gamma knife radiosurgery (GKRS). The maximal axial tumour diameter ranged from 6 to 33 mm (median: 25 mm), the maximal transverse tumour diameter ranged from 7 mm to 36 mm (median: 16 mm). The dose distributed to the tumour margin was 10 to 17 Gy (median: 12 Gy) by enclosing the tumour with the 40 % to 95 % isodose line (median: 50 % isodose line) and using 1 to 12 isocenters (median: 5 isocenters). Central loss of contrast enhancement was observed in 78 % of the patients within six to 12 months after radiosurgery. Thirty-two patients were observed over a minimum follow up period of at least 36 months, 9 patients were lost to follow up as they died of unrelated causes or refused further check-ups. Within the follow up period of up to seven years, magnetic resonance imaging (MRI) control scans revealed the tumour diameter stable or decreased in 29 cases and increased in three tumours. Of 14 patients with useful hearing before treatment, 9 patients were examined in addition to pure tone audiogramm by measurement of brainstem auditory evoked potentials (BAEPs) one to four years after radiosurgery. None of three patients showed a postoperative loss of the cochlea function. According to slight alterations of the cochlea function (cochlea summating action potential), pure tone audiometry of those patients revealed only slight changes of the hearing level (HL) within a maximum range of ±15 Decibel (dB). The hearing threshold improved in two, was stable in four and deteriorated in three patients, respectively. We observed postradiosurgical aggravation of a pre-existing facial

  19. Gamma knife radiosurgery of acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Bertalanffy, A; Dietrich, W; Aichholzer, M; Kitz, K [Department of Neurosurgery, University of Vienna, Medical School, Vienna (Austria); Heimberger, K [Department of Radiology, Division: Neuroradiology, University of Vienna, Medical School, Vienna (Austria); Brix, R [Department of Otorhinolaryngology, University of Vienna, Medical School, Vienna (Austria)

    2001-07-01

    The authors report on their series of 40 patients with 41 acoustic neurinomas (ACNs), including one patient with bilateral acoustic neurinomas suffering from neurofibromatosis type 2 (NF II) who were treated with the gamma knife unit at their institution between August 1992 and October 1995. Of these 41 tumours, 21 ACNs had been operated on before (l to 4 times), 20 ACNs were exclusively treated by gamma knife radiosurgery (GKRS). The maximal axial tumour diameter ranged from 6 to 33 mm (median: 25 mm), the maximal transverse tumour diameter ranged from 7 mm to 36 mm (median: 16 mm). The dose distributed to the tumour margin was 10 to 17 Gy (median: 12 Gy) by enclosing the tumour with the 40 % to 95 % isodose line (median: 50 % isodose line) and using 1 to 12 isocenters (median: 5 isocenters). Central loss of contrast enhancement was observed in 78 % of the patients within six to 12 months after radiosurgery. Thirty-two patients were observed over a minimum follow up period of at least 36 months, 9 patients were lost to follow up as they died of unrelated causes or refused further check-ups. Within the follow up period of up to seven years, magnetic resonance imaging (MRI) control scans revealed the tumour diameter stable or decreased in 29 cases and increased in three tumours. Of 14 patients with useful hearing before treatment, 9 patients were examined in addition to pure tone audiogramm by measurement of brainstem auditory evoked potentials (BAEPs) one to four years after radiosurgery. None of three patients showed a postoperative loss of the cochlea function. According to slight alterations of the cochlea function (cochlea summating action potential), pure tone audiometry of those patients revealed only slight changes of the hearing level (HL) within a maximum range of {+-}15 Decibel (dB). The hearing threshold improved in two, was stable in four and deteriorated in three patients, respectively. We observed postradiosurgical aggravation of a pre-existing facial

  20. Acoustic leak detection in piping systems, 4

    International Nuclear Information System (INIS)

    Kitajima, Akira; Naohara, Nobuyuki; Aihara, Akihiko

    1983-01-01

    To monitor a high-pressure piping of nuclear power plants, a possibility of acoustic leak detection method has been experimentally studied in practical field tests and laboratory tests. Characteristics of background noise in field test and the results of experiment are summarized as follows: (1) The level of background noise in primary loop (PWR) was almost constant under actual plant operation. But it is possible that it rises at the condition of the pressure in primary loop. (2) Based on many experience of laboratory tests and practical field tests. The leak monitoring system for practical field was designed and developed. To improve the reliability, a judgment of leak on this system is used three factors of noise level, duration time of phenomena and frequency spectrum of noise signal emitted from the leak point. (author)

  1. Radiopharmaceuticals as probes to characterize tumour tissue

    International Nuclear Information System (INIS)

    Alam, Israt S.; Arshad, Mubarik A.; Nguyen, Quang-De; Aboagye, Eric O.

    2015-01-01

    Tumour cells exhibit several properties that allow them to grow and divide. A number of these properties are detectable by nuclear imaging methods. We discuss crucial tumour properties that can be described by current radioprobe technologies, further discuss areas of emerging radioprobe development, and finally articulate need areas that our field should aspire to develop. The review focuses largely on positron emission tomography and draws upon the seminal 'Hallmarks of Cancer' review article by Hanahan and Weinberg in 2011 placing into context the present and future roles of radiotracer imaging in characterizing tumours. (orig.)

  2. Detection of unknown primary neuroendocrine tumours (CUP-NET) using 68Ga-DOTA-NOC receptor PET/CT

    International Nuclear Information System (INIS)

    Prasad, Vikas; Baum, Richard P.; Ambrosini, Valentina; Fanti, Stefano; Hommann, Merten; Hoersch, Dieter

    2010-01-01

    This bi-centric study aimed to determine the role of receptor PET/CT using 68 Ga-DOTA-NOC in the detection of undiagnosed primary sites of neuroendocrine tumours (NETs) and to understand the molecular behaviour of the primarily undiagnosed tumours. Overall 59 patients (33 men and 26 women, age: 65 ± 9 years) with documented NET and unknown primary were enrolled. PET/CT was performed after injection of approximately 100 MBq (46-260 MBq) of 68 Ga-DOTA-NOC. The maximum standardised uptake values (SUV max ) were calculated and compared with SUV max in known pancreatic NET (pNET) and ileum/jejunum/duodenum (SI-NET). The results of PET/CT were also correlated with CT alone. In 35 of 59 patients (59%), 68 Ga-DOTA-NOC PET/CT localised the site of the primary: ileum/jejunum (14), pancreas (16), rectum/colon (2), lungs (2) and paraganglioma (1). CT alone (on retrospective analyses) confirmed the findings in 12 of 59 patients (20%). The mean SUV max of identified previously unknown pNET and SI-NET were 18.6 ± 9.8 (range: 7.8-34.8) and 9.1 ± 6.0 (range: 4.2-27.8), respectively. SUV max in patients with previously known pNET and SI-NET were 26.1 ± 14.5 (range: 8.7-42.4) and 11.3 ± 3.7 (range: 5.6-17.9). The SUV max of the unknown pNET and SI-NET were significantly lower (p 68 Ga-DOTA-NOC receptor PET/CT, 6 of 59 patients were operated and the primary was removed (4 pancreatic, 1 ileal and 1 rectal tumour) resulting in a management change in approximately 10% of the patients. In the remaining 29 patients, because of the far advanced stage of the disease (due to distant metastases), the primary tumours were not operated. Additional histopathological sampling was available from one patient with bronchial carcinoid (through bronchoscopy). Our data indicate that 68 Ga-DOTA-NOC PET/CT is highly superior to 111 In-OctreoScan (39% detection rate for CUP according to the literature) and can play a major role in the management of patients with CUP-NET. (orig.)

  3. [Mobile phones and head tumours: it is time to read and highlight data in a proper way].

    Science.gov (United States)

    Levis, Angelo G; Minicucci, Nadia; Ricci, Paolo; Gennaro, Valerio; Garbisa, Spiridione

    2011-01-01

    The uncertainty about the relationship between the use of mobile phones (MPs: analogue and digital cellulars, and cordless) and the increase of head tumour risk can be solved by a critical analysis of the methodological elements of both the positive and the negative studies. Results by Hardell indicate a cause/effect relationship: exposures for or latencies from ≥ 10 years to MPs increase by up to 100% the risk of tumour on the same side of the head preferred for phone use (ipsilateral tumours) - which is the only one significantly irradiated - with statistical significance for brain gliomas, meningiomas and acoustic neuromas. On the contrary, studies published under the Interphone project and others produced negative results and are characterised by the substantial underestimation of the risk of tumour. However, also in the Interphone studies a clear and statistically significant increase of ipsilateral head tumours (gliomas, neuromas and parotid gland tumours) is quite common in people having used MPs since or for ≥ 10 years. And also the metaanalyses by Hardell and other Authors, including only the literature data on ipsilateral tumours in people having used MPs since or for ≥ 10 years - and so also part of the Interphone data - still show statistically significant increases of head tumours.

  4. Detection of unknown primary neuroendocrine tumours (CUP-NET) using {sup 68}Ga-DOTA-NOC receptor PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, Vikas; Baum, Richard P. [Zentralklinik Bad Berka, Department of Nuclear Medicine and Centre for PET/CT, Bad Berka (Germany); Ambrosini, Valentina; Fanti, Stefano [University of Bologna, Nuclear Medicine Unit, Policlinico S. Orsola-Malpighi, Bologna (Italy); Hommann, Merten [Zentralklinik Bad Berka, Department of General and Visceral Surgery, Bad Berka (Germany); Hoersch, Dieter [Zentralklinik Bad Berka, Department of Internal Medicine/Gastroenterology, Oncology and Endocrinology, Bad Berka (Germany)

    2010-01-15

    This bi-centric study aimed to determine the role of receptor PET/CT using {sup 68}Ga-DOTA-NOC in the detection of undiagnosed primary sites of neuroendocrine tumours (NETs) and to understand the molecular behaviour of the primarily undiagnosed tumours. Overall 59 patients (33 men and 26 women, age: 65 {+-} 9 years) with documented NET and unknown primary were enrolled. PET/CT was performed after injection of approximately 100 MBq (46-260 MBq) of {sup 68}Ga-DOTA-NOC. The maximum standardised uptake values (SUV{sub max}) were calculated and compared with SUV{sub max} in known pancreatic NET (pNET) and ileum/jejunum/duodenum (SI-NET). The results of PET/CT were also correlated with CT alone. In 35 of 59 patients (59%), {sup 68}Ga-DOTA-NOC PET/CT localised the site of the primary: ileum/jejunum (14), pancreas (16), rectum/colon (2), lungs (2) and paraganglioma (1). CT alone (on retrospective analyses) confirmed the findings in 12 of 59 patients (20%). The mean SUV{sub max} of identified previously unknown pNET and SI-NET were 18.6 {+-} 9.8 (range: 7.8-34.8) and 9.1 {+-} 6.0 (range: 4.2-27.8), respectively. SUV{sub max} in patients with previously known pNET and SI-NET were 26.1 {+-} 14.5 (range: 8.7-42.4) and 11.3 {+-} 3.7 (range: 5.6-17.9). The SUV{sub max} of the unknown pNET and SI-NET were significantly lower (p < 0.05) as compared to the ones with known primary tumour sites; 19% of the patients had high-grade and 81% low-grade NET. Based on {sup 68}Ga-DOTA-NOC receptor PET/CT, 6 of 59 patients were operated and the primary was removed (4 pancreatic, 1 ileal and 1 rectal tumour) resulting in a management change in approximately 10% of the patients. In the remaining 29 patients, because of the far advanced stage of the disease (due to distant metastases), the primary tumours were not operated. Additional histopathological sampling was available from one patient with bronchial carcinoid (through bronchoscopy). Our data indicate that {sup 68}Ga-DOTA-NOC PET/CT is

  5. Out-of-pile experiments with an electrical boiler for Acoustic Boiling Detection

    International Nuclear Information System (INIS)

    Aberle, J.; Bartholomay, R.; Reimann, G.; Rohrbacher, H.A.; Schleisiek, K.

    1978-03-01

    This report contains the experimental results of boiling tests obtained during the first testing phase in spring 1977 with an electrically heated 18-rod boiling generator installed in the sodium tank facility (NABEA) of IRE. The layout and performance of the boiling facility together with its instrumentation and criteria of selection of acoustic sensors for the detection of sodium boiling are described and discussed. The report provides information about the thermodynamics, blockage design and thermal conduction within the range of installation of the electric connecting head. The evaluation of the acoustic signals shows that boiling is indicated promptly and with a sufficiently high signal-to-noise ratio both by solid-born sensors and by high temperature microphones placed in the sodium

  6. Acoustic leak detection at complicated geometrical structures using fuzzy logic and neural networks

    International Nuclear Information System (INIS)

    Hessel, G.; Schmitt, W.; Weiss, F.P.

    1993-10-01

    An acoustic method based on pattern recognition is being developed. During the learning phase, the localization classifier is trained with sound patterns that are generated with simulated leaks at all locations endangered by leak. The patterns are extracted from the signals of an appropriate sensor array. After training unknown leak positions can be recognized through comparison with the training patterns. The experimental part is performed at an acoustic 1:3 model of the reactor vessel and head and at an original VVER-440 reactor in the former NPP Greifswald. The leaks were simulated at the vessel head using mobile sound sources driven either by compressed air, a piezoelectric transmitter or by a thin metal blade excited through a jet of compressed air. The sound patterns of the simulated leaks are simultaneously detected with an AE-sensor array and with high frequency microphones measuring structure-borne sound and airborne sound, respectively. Pattern classifiers based on Fuzzy Pattern Classification (FPC) and Artificial Neural Networks (ANN) are currently tested for validation of the acoustic emission-sensor array (FPC), leak localization via structure-borne sound (FPC) and the leak localization using microphones (ANN). The initial results show the used classifiers principally to be capable of detecting and locating leaks, but they also show that further investigations are necessary to develop a reliable method applicable at NPPs. (orig./HP)

  7. Critical heat flux acoustic detection: Methods and application to ITER divertor vertical target monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, X., E-mail: xavier.courtois@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Escourbiac, F. [ITER Organization, Route de Vinon sur Verdon, F-13115 Saint-Paul-Lez-Durance (France); Richou, M.; Cantone, V. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Constans, S. [AREVA-NP, Le Creusot (France)

    2013-10-15

    Actively cooled plasma facing components (PFCs) have to exhaust high heat fluxes from plasma radiation and plasma–wall interaction. Critical heat flux (CHF) event may occur in the cooling channel due to unexpected heat loading or operational conditions, and has to be detected as soon as possible. Therefore it is essential to develop means of monitoring based on precursory signals providing an early detection of this destructive phenomenon, in order to be able to stop operation before irremediable damages appear. Capabilities of CHF early detection based on acoustic techniques on PFC mock-ups cooled by pressurised water were already demonstrated. This paper addresses the problem of the detection in case of flow rate reduction and of flow dilution resulting from multiple plasma facing units (PFU) which are hydraulically connected in parallel, which is the case of ITER divertor. An experimental study is launched on a dedicated mock-up submitted to heat loads up to the CHF. It shows that the measurement of the acoustic waves, generated by the cooling phenomena, allows the CHF detection in conditions similar to that of the ITER divertor, with a reasonable number of sensors. The paper describes the mock-ups and the tests sequences, and comments the results.

  8. Detection and quantification of focal uptake in head and neck tumours: {sup 18}F-FDG PET/MR versus PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Varoquaux, Arthur; Rager, Olivier; Ratib, Osman; Becker, Christoph D.; Zaidi, Habib; Becker, Minerva [Geneva University Hospital, Department of Imaging, Divisions of Radiology and Nuclear Medicine, Geneva 14 (Switzerland); Poncet, Antoine [Geneva University Hospital, Center for Clinical Research, Geneva (Switzerland); Delattre, Benedicte M.A. [Geneva University Hospital, Department of Imaging, Divisions of Radiology and Nuclear Medicine, Geneva 14 (Switzerland); Philips Healthcare AG, Nuclear Medicine Division, Gland (Switzerland); Dulguerov, Pavel; Dulguerov, Nicolas [Geneva University Hospital, Clinic of Otorhinolaryngology Head and Neck Surgery, Geneva (Switzerland)

    2014-03-15

    Our objectives were to assess the quality of PET images and coregistered anatomic images obtained with PET/MR, to evaluate the detection of focal uptake and SUV, and to compare these findings with those of PET/CT in patients with head and neck tumours. The study group comprised 32 consecutive patients with malignant head and neck tumours who underwent whole-body {sup 18}F-FDG PET/MR and PET/CT. PET images were reconstructed using the attenuation correction sequence for PET/MR and CT for PET/CT. Two experienced observers evaluated the anonymized data. They evaluated image and fusion quality, lesion conspicuity, anatomic location, number and size of categorized (benign versus assumed malignant) lesions with focal uptake. Region of interest (ROI) analysis was performed to determine SUVs of lesions and organs for both modalities. Statistical analysis considered data clustering due to multiple lesions per patient. PET/MR coregistration and image fusion was feasible in all patients. The analysis included 66 malignant lesions (tumours, metastatic lymph nodes and distant metastases), 136 benign lesions and 470 organ ROIs. There was no statistically significant difference between PET/MR and PET/CT regarding rating scores for image quality, fusion quality, lesion conspicuity or anatomic location, number of detected lesions and number of patients with and without malignant lesions. A high correlation was observed for SUV{sub mean} and SUV{sub max} measured on PET/MR and PET/CT for malignant lesions, benign lesions and organs (ρ = 0.787 to 0.877, p < 0.001). SUV{sub mean} and SUV{sub max} measured on PET/MR were significantly lower than on PET/CT for malignant tumours, metastatic neck nodes, benign lesions, bone marrow, and liver (p < 0.05). The main factor affecting the difference between SUVs in malignant lesions was tumour size (p < 0.01). In patients with head and neck tumours, PET/MR showed equivalent performance to PET/CT in terms of qualitative results. Comparison of

  9. Intra-operative cerebrospinal fluid sampling versus post-operative lumbar puncture for detection of leptomeningeal disease in malignant paediatric brain tumours.

    Directory of Open Access Journals (Sweden)

    Sharon Y Y Low

    Full Text Available Leptomeningeal disease is a feared sequelae of malignant paediatric brain tumours. Current methods for its detection is the combined use of cranio-spinal MRI, and CSF cytology from a post-operative lumbar puncture. In this study, the authors hypothesize that CSF taken at the start of surgery, either from an external ventricular drain or neuroendoscope will have equal sensitivity for positive tumour cells, in comparison to lumbar puncture. Secondary hypotheses include positive correlation between CSF cytology and MRI findings of LMD. From a clinical perspective, the key aim of the study was for affected paediatric patients to avoid an additional procedure of a lumbar puncture, often performed under anaesthesia after neurosurgical intervention.This is single-institution, retrospective study of paediatric patients diagnosed with malignant brain tumours. Its main aim was to compare cytological data from CSF collected at the time of surgery versus data from an interval lumbar puncture. In addition, MRI imaging of the same cohort of patients was examined for leptomeningeal disease and corroborated against CSF tumour cytology findings.Thirty patients are recruited for this study. Data analysis demonstrates a statistically significant association between our intra-operative CSF and LP sampling. Furthermore, our results also show for significant correlation between evidence of leptomeningeal disease on MRI findings versus intra-operative CSF positivity for tumour cells.Although this is a retrospective study with a limited population, our data concurs with potential to avoid an additional procedure for the paediatric patient diagnosed with a malignant brain tumour.

  10. Neurohypophysis granular cell tumours. Upon neurohypophysis rare tumours

    International Nuclear Information System (INIS)

    Barrande, G.; Kujas, M.; Gancel, A.; Turpin, G.; Bruckert, E.; Kuhn, J.M.; Luton, J.P.

    1995-01-01

    Granular cell tumours of neurohypophysis are rare. These tumours are more often encountered as incidental autopsy findings seen in up to 17 % of unselected adult autopsy cases. There are few reports of para-sellar granular cell tumours large enough to cause symptoms. We present three cases of neurohypophysis granular cell tumour and a review of the literature. In one patient, the asymptomatic granular cell tumour was incidentally discovered at surgical removal of a corticotrophic micro-adenoma. The remaining 2 patients had a symptomatic tumour which caused neurological symptoms such as visual disturbance and headaches and endocrine disorders such as hypopituitarism or hyper-prolactinaemia. In these 2 cases, computerized tomography showed a well-circumscribed, contrast-enhanced, intra-sellar and supra-sellar mass. Magnetic resonance imaging demonstrated an isointense gadolinium-enhanced mass in T1-weighted-images. Trans-sphenoidal partial resection was performed and histology was interpreted as a granular cell tumour. The immunohistochemical study was positive for glial fibrillary acidic protein (GEAP) and neuron specific enolase (NSE) in 1 of the 2 tumours and positive for S100 protein and vimentin in both tumours but negative for CD68. The histogenesis of neurohypophysis granular cell tumours is still controversial but ultrastructural and immunohistochemical studies support the theory that may arise from pituicytes, the glial cells of neurohypophysis. Management of these benign, slow growing, tumours is based mainly on neurosurgical resection. Data from the literature do not support a beneficial effect of post operative radiation therapy on postoperative recurrences. (authors). 23 refs., 4 figs., 1 tab

  11. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    Science.gov (United States)

    Zhang, Tongzhi; Pang, Fufei; Liu, Huanhuan; Cheng, Jiajing; Lv, Longbao; Zhang, Xiaobei; Chen, Na; Wang, Tingyun

    2016-01-01

    We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad/(m⋅Pa). A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work. PMID:27916900

  12. Metformin treatment modulates the tumour-induced wasting effects in muscle protein metabolism minimising the cachexia in tumour-bearing rats

    International Nuclear Information System (INIS)

    Oliveira, André G.; Gomes-Marcondes, Maria Cristina C.

    2016-01-01

    Cancer-cachexia state frequently induces both fat and protein wasting, leading to death. In this way, the knowledge of the mechanism of drugs and their side effects can be a new feature to treat and to have success, contributing to a better life quality for these patients. Metformin is an oral drug used in type 2 diabetes mellitus, showing inhibitory effect on proliferation in some neoplastic cells. For this reason, we evaluated its modulatory effect on Walker-256 tumour evolution and also on protein metabolism in gastrocnemius muscle and body composition. Wistar rats received or not tumour implant and metformin treatment and were distributed into four groups, as followed: control (C), Walker 256 tumour-bearing (W), metformin-treated (M) and tumour-bearing treated with metformin (WM). Animals were weighed three times a week, and after cachexia state has been detected, the rats were euthanised and muscle and tumour excised and analysed by biochemical and molecular assays. Tumour growth promoted some deleterious effects on chemical body composition, increasing water and decreasing fat percentage, and reducing lean body mass. In muscle tissue, tumour led to a decreased protein synthesis and an increased proteolysis, showing the higher activity of the ubiquitin-proteasome pathway. On the other hand, the metformin treatment likely minimised the tumour-induced wasting state; in this way, this treatment ameliorated chemical body composition, reduced the higher activities of proteolytic enzymes and decreased the protein waste. Metformin treatment not only decreases the tumour growth but also improves the protein metabolism in gastrocnemius muscle in tumour-bearing rats

  13. Using of acoustic technologies for detection of explosives in gas, liquid and solid medium

    International Nuclear Information System (INIS)

    Valyaev, A. N.; Yanushkevich, V.A.

    2004-01-01

    Full text: Some industrial nuclear power objects are very attractive for the realization of radiological and chemical terrorism acts with using of explosives. Although up today this type of terrorism is not revealed itself, but the problem of detection of explosives at these objects is becoming very actual one, for example, in connection with the implementation of the urgent decommissioning of nuclear powered vessels. Such decommissioning includes the utilization the dangerous radioactive and chemical elements, contained in submarines and vessels. This actual problem is existed not only in Russia, but also in abroad. It is noticed that catastrophes at these objects will have in addition the great negative mental effect on population of all over the world, as it was after the Chernobyl accident. The using of the modern nuclear physics methods for detection and analysis of explosives is connected with the following difficulties: (1) we have to have the unique and the expensive equipment; (2) the special preparation of sample probes; (3) a long time is often necessary for analysis; (4) the high qualification of service personal is needed. We proposed to use for these purposes the complex of acoustic techniques, that are based on the high sensitivity of acoustic characteristics of any matter to their physical and chemical properties.Any acoustic signal has the following main parameters: (1) frequency (ω); (2) amplitude of pressure (ρ); (3) wave and amplitude bands; (4) velocity of acoustic wave propagation (sound velocity) (C); (5) space and temporal signal evolution, that is determined by the values of coefficients of temporal attenuation (α), space adsorption (β) and sound dispersion on obstacles and impurities. Our acoustic analysis is included the determination of C, α and β values for solid and liquid explosives. The exact measurements of these parameters and their dependences from frequency and temperature are conducted in the special acoustic cells, that

  14. Detection and localisation of very high energy particles in underwater acoustic; Detection et localisation de particules de tres hautes energies en acoustique sous-marine

    Energy Technology Data Exchange (ETDEWEB)

    Juennard, N

    2007-12-15

    The theme of this thesis is included in the Antares international project whose object is to build a neutrino telescope located in a deep water environment in the Mediterranean sea. In deep water sea, a neutrino can interact with a water molecule. The collision generates a luminous flash and an acoustic wave. The goal of this work is to study this acoustic sound wave and develop a system able to detect the corresponding wave front and to estimate the initial direction of the particle. We first focus on the acoustic sound wave. Two different models are studied, and works made recently have led to a mathematical expression of both signal and wave front. Then, several detection methods are studied, from the most classical to the more recent ones. The experimental comparison in semi-real situation leads to the choice of a detection method: the Extended stochastic matched filter. Position and direction of the neutrino are now estimated with a Gauss-Newton inspired algorithm. This estimator is based on a wave front propagation model and on the time detection information given by the telescope hydro-phones. Performances of the system are then estimated. An antenna structure is then proposed and a global simulation finalizes this thesis. In this simulation, detection and estimation are based on the results found in the previous sections. Underwater sea noise is real and the results of the simulation valid our works. (author)

  15. In vivo imaging of chromogranin A-positive endocrine tumours by three-step monoclonal antibody targeting

    International Nuclear Information System (INIS)

    Siccardi, A.G.; Paganelli, G.; Pontiroli, A.E.; Pelagi, M.; Magnani, P.; Viale, G.; Faglia, G.; Fazio, F.

    1996-01-01

    The detection of chromogranins (Cg) by immunohistochemistry and serology represents a new in vitro diagnostic tool for endocrine tumours. We have recently reported on the feasibility of targeting chromogranin A (CgA) for in vivo detection of pituitary adenomas by immunoscintigraphy (ISG). The scintigraphic procedure, based on an anti-CgA monoclonal antibody and on the avidin-biotin three-step method (Cg-3S-ISG), was evaluated on a group of 29 consecutive patients with known or suspected endocrine tumours other than pituitary adenomas, i.e. medullary thyroid carcinoma, carcinoid, insulinoma and parathormone- or ACTH-producing tumours. Primary tumours (10) and recurrences (16) were visualised in 26 patients, whereas conventional imaging techniques (planar radiography, computerised tomography, magnetic resonance imaging and ultrasonography) failed to detect the tumour sites in ten of the same (Cg-3S-ISG-positive) patients. Therefore, these preliminary results indicate that Cg-3S-ISG, the first immunological method able to detect endocrine tumours in vivo, has a higher diagnostic accuracy than conventional imaging techniques (93.1% compared with 65.5%). (orig.). With 3 figs., 1 tab

  16. Calibration of sensors for acoustic detection of neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Ardid, M; Bou-Cabo, M; Espinosa, V; Martinez-Mora, J; Camarena, F; Alba, J [Departament de Fisica Aplicada, E.P.S. Gandia, Universitat Politecnica de Valencia, Cra. Nazaret/Oliva S/N, E-46730 Gandia (Spain)

    2007-09-15

    Calibration of sensors is an important task for the acoustic detection of neutrinos. Different approaches have been tried and used (calibrated hydrophones, resistors, powerful lasers, light bulbs explosion, etc.) We propose some methods for calibration that can be used in both the lab and the telescope ('in situ'). In this paper, different studies following these methods and their results are reported. First, we describe the reciprocity calibration method for acoustic sensors. Since it is a simple method and calibrated hydrophones are not needed, this technique is accessible for any lab. Moreover, the technique could be used to calibrate the sensors of a neutrino telescope just by using themselves (reciprocally). A comparison of this technique using different kind of signals (MLS, TSP, tone bursts, white noise), and in different propagation conditions is presented. The limitations of the technique are shown, as well as some possibilities to overcome them. The second aspect treated is the obtaining of neutrinolike signals for calibration. Probably, the most convenient way to do it would be to generate these signals from transducers directly. Since transducers do not usually have a flat frequency response, distortion is produced, and neutrino-like signals could be difficult to achieve. We present some equalization techniques to offset this effect. In this sense, the use of inverse filter based in Mourjopoulos theory seems to be quite convenient.

  17. Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography.

    Science.gov (United States)

    Büther, Florian; Ernst, Iris; Dawood, Mohammad; Kraxner, Peter; Schäfers, Michael; Schober, Otmar; Schäfers, Klaus P

    2010-12-01

    Respiratory motion of organs during PET scans is known to degrade PET image quality, potentially resulting in blurred images, attenuation artefacts and erroneous tracer quantification. List mode-based gating has been shown to reduce these pitfalls in cardiac PET. This study evaluates these intrinsic gating methods for tumour PET scans. A total of 34 patients with liver or lung tumours (14 liver tumours and 27 lung tumours in all) underwent a 15-min single-bed list mode PET scan of the tumour region. Of these, 15 patients (8 liver and 11 lung tumours in total) were monitored by a video camera registering a marker on the patient's abdomen, thus capturing the respiratory motion for PET gating (video method). Further gating information was deduced by dividing the list mode stream into 200-ms frames, determining the number of coincidences (sensitivity method) and computing the axial centre of mass of the measured count rates in the same frames (centre of mass method). Additionally, these list mode-based methods were evaluated using only coincidences originating from the tumour region by segmenting the tumour in sinogram space (segmented sensitivity/centre of mass method). Measured displacement of the tumours between end-expiration and end-inspiration and the increase in apparent uptake in the gated images served as a measure for the exactness of gating. To estimate the accuracy, a thorax phantom study with moved activity sources simulating small tumours was also performed. All methods resolved the respiratory motion with varying success. The best results were seen in the segmented centre of mass method, on average leading to larger displacements and uptake values than the other methods. The simple centre of mass method performed worse in terms of displacements due to activities moving into the field of view during the respiratory cycle. Both sensitivity- and video-based methods lead to similar results. List mode-driven PET gating, especially the segmented centre of mass

  18. [Treatment of giant acoustic neuromas].

    Science.gov (United States)

    Samprón, Nicolás; Altuna, Xabier; Armendáriz, Mikel; Urculo, Enrique

    2014-01-01

    To analyze the treatment modality and outcome of a series of patients with giant acoustic neuromas, a particular type of tumour characterised by their size (extracanalicular diameter of 4cm or more) and high morbidity and mortality. This was a retrospective unicentre study of patients with acoustic neuromas treated in a period of 12 years. In our institutional series of 108 acoustic neuromas operated on during that period, we found 13 (12%) cases of giant acoustic neuromas. We reviewed the available data of these cases, including presentation and several clinical, anatomical, and microsurgical aspects. All patients were operated on by the same neurosurgeon and senior author (EU) using the suboccipital retrosigmoid approach and complete microsurgical removal was achieved in 10 cases. In one case, near total removal was deliberately performed, in another case a CSF shunt was placed as the sole treatment measure, and in the remaining case no direct treatment was given. One patient died in the immediate postoperative period. One year after surgery, 4 patients showed facial nerve function of iii or more in the House-Brackman scale. The 4 most important prognostic characteristics of giant acoustic neuromas are size, adhesion to surrounding structures, consistency and vascularity. Only the first of these is evident in neuroimaging. Giant acoustic neuromas are characterised by high morbidity at presentation as well as after treatment. Nevertheless, the objective of complete microsurgical removal with preservation of cranial nerve function is attainable in some cases through the suboccipital retrosigmoid approach. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  19. Diagnostic value of somatostatin receptor scintigraphy in patients with intracranial tumours

    International Nuclear Information System (INIS)

    Luyken, C.; Hildebrandt, G.; Scheidhauer, K.; Kirsch, B.

    1993-01-01

    The aim of the study was to detect the SR binding sites in intracranial tumours and to evaluate the benefit of SRS in pre- and postoperative diagnostics. 86 patients with 94 intracranial tumours (39 meningiomas, 18 pituitary adenomas, 11 gliomas grade 3 or 4, 8 gliomas grade 2, 5 neurinomas, 5 intracranial metastases, 4 tumours of the orbit, 2 neurofibromas, 1 brain abscess and 1 cystic lesion) were examined. 111 In-octreotide was injected i.v. as 10 μg or 20 μg bolus, corresponding to 110 or 220 MBq (3 or 6 mCi). Gamma-camera images and SPECT were obtained 3-6 h and 24 h post injection. The scintigraphic evaluation was performed without knowledge of CT and MRI results. The histological classification corresponded to the WHO grading system. Somatostatin binding sites were detected in vito using somatostatin-gold conjugates. All patients with meningiomas showed a high focal tracer uptake corresponding to SR binding sites in vitro, whereas only in 50% of the pituitary adenomas SRS was positive. Neurinomas did not show any tracer uptake. In patients with gliomas with disturbed blood-brain-barrier positive tracer uptake was detected, while none of the gliomas with intact blood-brain-barrier could be visualized by SRS but showed somatostatin binding sites in vitro. In intracranial metastases a local tracer uptake was detected in vivo. In vitro 3 of 4 cases showed somatostatin binding sites. In 2 cases extracranial tracer uptake showed the primary tumour and metastases of the lymphnodes. Somatostatin receptor scintigraphy can help to detect or to exclude meningiomas especially in the cerebellopontine angle or in the orbit. In intracranial metastases SRS may point to the primary tumour or other metastases. In all other intracranial tumours receptor scintigraphy provides no clinical relevant information. (orig./MG) [de

  20. Development of sensors for the acoustic detection of ultra high energy neutrinos in the deep sea

    International Nuclear Information System (INIS)

    Naumann, C.L.

    2007-01-01

    In addition to the optical detection system used by the ANTARES detector, a proposal was made to include an acoustic system consisting of several modified ANTARES storeys to investigate the feasibility of building and operating an acoustic particle detection system in the deep sea and at the same time perform an extensive study of the acoustic properties of the deep sea environment. The directional characteristics of the sensors and their placement within the ANTARES detector had to be optimised for the study of the correlation properties of the acoustic noise at different length scales - from below a metre to above 100 metres. The so-called ''equivalent circuit diagram (=ECD) model'' - was applied to predict the acoustic properties of piezo elements, such as sensitivity and intrinsic noise, and was extended by including effects resulting from the geometrical shape of the sensors. A procedure was devised to gain the relevant ECD parameters from electrical impedance measurements of the piezo elements, both free and coupled to a surrounding medium. Based on the findings of this ECD model, intensive design studies were performed with prototype hydrophones using piezo elements as active sensors. The design best suited for the construction of acoustic sensors for ANTARES was determined, and a total of twelve hydrophones were built with a sensitivity of -145 to -140 dB re 1V/μPa between 5 and 50 kHz and an intrinsic noise power density around -90 dB re 1 V/√(Hz), giving a total noise rms of 7 mV in this frequency range. The hydrophones were pressure tested and calibrated for integration into the ANTARES acoustic system. In addition, three so-called Acoustic Modules, sensors in pressure resistant glass spheres with a sensitive bandwidth of about 80 kHz, were developed and built. The calibration procedure employed during the sensor design studies as well as for the final sensors to be installed in the ANTARES framework is presented, together with exemplary results for

  1. Development of sensors for the acoustic detection of ultra high energy neutrinos in the deep sea

    Energy Technology Data Exchange (ETDEWEB)

    Naumann, C.L.

    2007-09-17

    In addition to the optical detection system used by the ANTARES detector, a proposal was made to include an acoustic system consisting of several modified ANTARES storeys to investigate the feasibility of building and operating an acoustic particle detection system in the deep sea and at the same time perform an extensive study of the acoustic properties of the deep sea environment. The directional characteristics of the sensors and their placement within the ANTARES detector had to be optimised for the study of the correlation properties of the acoustic noise at different length scales - from below a metre to above 100 metres. The so-called 'equivalent circuit diagram (=ECD) model' - was applied to predict the acoustic properties of piezo elements, such as sensitivity and intrinsic noise, and was extended by including effects resulting from the geometrical shape of the sensors. A procedure was devised to gain the relevant ECD parameters from electrical impedance measurements of the piezo elements, both free and coupled to a surrounding medium. Based on the findings of this ECD model, intensive design studies were performed with prototype hydrophones using piezo elements as active sensors. The design best suited for the construction of acoustic sensors for ANTARES was determined, and a total of twelve hydrophones were built with a sensitivity of -145 to -140 dB re 1V/{mu}Pa between 5 and 50 kHz and an intrinsic noise power density around -90 dB re 1 V/{radical}(Hz), giving a total noise rms of 7 mV in this frequency range. The hydrophones were pressure tested and calibrated for integration into the ANTARES acoustic system. In addition, three so-called Acoustic Modules, sensors in pressure resistant glass spheres with a sensitive bandwidth of about 80 kHz, were developed and built. The calibration procedure employed during the sensor design studies as well as for the final sensors to be installed in the ANTARES framework is presented, together with

  2. Target detection and localization in shallow water: an experimental demonstration of the acoustic barrier problem at the laboratory scale.

    Science.gov (United States)

    Marandet, Christian; Roux, Philippe; Nicolas, Barbara; Mars, Jérôme

    2011-01-01

    This study demonstrates experimentally at the laboratory scale the detection and localization of a wavelength-sized target in a shallow ultrasonic waveguide between two source-receiver arrays at 3 MHz. In the framework of the acoustic barrier problem, at the 1/1000 scale, the waveguide represents a 1.1-km-long, 52-m-deep ocean acoustic channel in the kilohertz frequency range. The two coplanar arrays record in the time-domain the transfer matrix of the waveguide between each pair of source-receiver transducers. Invoking the reciprocity principle, a time-domain double-beamforming algorithm is simultaneously performed on the source and receiver arrays. This array processing projects the multireverberated acoustic echoes into an equivalent set of eigenrays, which are defined by their launch and arrival angles. Comparison is made between the intensity of each eigenray without and with a target for detection in the waveguide. Localization is performed through tomography inversion of the acoustic impedance of the target, using all of the eigenrays extracted from double beamforming. The use of the diffraction-based sensitivity kernel for each eigenray provides both the localization and the signature of the target. Experimental results are shown in the presence of surface waves, and methodological issues are discussed for detection and localization.

  3. Whole-body MRI at 1.5 T and 3 T compared with FDG-PET-CT for the detection of tumour recurrence in patients with colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, G.P.; Baur-Melnyk, A.; Becker, C.R.; Reiser, M.F.; Hermann, K.A. [Ludwig Maximilian University Munich, Department of Clinical Radiology, University Hospitals Grosshadern, Munich (Germany); Haug, A.; Tiling, R. [University Hospitals Grosshadern, Ludwig Maximilian University Munich, Department of Nuclear Medicine, Munich (Germany); Utzschneider, S. [University Hospitals Grosshadern, Ludwig Maximilian University Munich, Department of Orthopedics, Munich (Germany)

    2009-06-15

    The purpose of this study was to assess the diagnostic accuracy of whole-body MRI (WB-MRI) at 1.5 T or 3 T compared with FDG-PET-CT in the follow-up of patients suffering from colorectal cancer. In a retrospective study, 24 patients with a history of colorectal cancer and suspected tumour recurrence underwent FDG-PET-CT and WB-MRI with the use of parallel imaging (PAT) for follow-up. High resolution coronal T1w-TSE and STIR sequences at four body levels, HASTE imaging of the lungs, contrast-enhanced T1w- and T2w-TSE sequences of the liver, brain, abdomen and pelvis were performed, using WB-MRI at either 1.5 T (n = 14) or 3 T (n = 10). Presence of local recurrent tumour, lymph node involvement and distant metastatic disease was confirmed using radiological follow-up within at least 5 months as a standard of reference. Seventy seven malignant foci in 17 of 24 patients (71%) were detected with both WB-MRI and PET-CT. Both investigations concordantly revealed two local recurrent tumours. PET-CT detected significantly more lymph node metastases (sensitivity 93%, n = 27/29) than WB-MRI (sensitivity 63%, n = 18/29). PET-CT and WB-MRI achieved a similar sensitivity for the detection of organ metastases with 80% and 78%, respectively (37/46 and 36/46). WB-MRI detected brain metastases in one patient. One false-positive local tumour recurrence was indicated by PET-CT. Overall diagnostic accuracy for PET-CT was 91% (sensitivity 86%, specificity 96%) and 83% for WB-MRI (sensitivity 72%, specificity 93%), respectively. Examination time for WB-MRI at 1.5 T and 3 T was 52 min and 43 min, respectively; examination time for PET-CT was 103 min. Initial results suggest that differences in accuracy for local and distant metastases detection using FDG-PET-CT and WB-MRI for integrated screening of tumour recurrence in colorectal cancer depend on the location of the malignant focus. Our results show that nodal disease is better detected using PET-CT, whereas organ disease is depicted

  4. Childhood Adrenocortical Tumours: a Review

    Directory of Open Access Journals (Sweden)

    Marques-Pereira Rosana

    2006-05-01

    Full Text Available Abstract Childhood adrenocortical tumour (ACT is not a common disease, but in southern Brazil the prevalence is 15 times higher than in other parts of the world. One hundred and thirty-seven patients have been identified and followed by our group over the past four decades. Affected children are predominantly girls, with a female-to-male ratio of 3.5:1 in patients below 4 years of age. Virilization alone (51.6% or mixed with Cushing's syndrome (42.0% was the predominant clinical picture observed in these patients. Tumours are unilateral, affecting both glands equally. TP53 R337H germline mutations underlie most childhood ACTs in southern Brazil. Epidemiological data from our casuistic studies revealed that this mutation has ~10% penetrance for ACT. Surgery is the definitive treatment, and a complete resection should always be attempted. Although adjuvant chemotherapy has shown some encouraging results, its influence on overall outcome is small. The survival rate is directly correlated to tumour size; patients with small, completely excised tumours have survival rates close to 90%, whereas in those patients with inoperable tumours and/or metastatic disease it is less than 10%. In the group of patients with large, excisable tumours, half of them have an intermediate outcome. Recent molecular biology techniques and genomic approaches may help us to better understand the pathogenesis of ACT, the risk of developing a tumour when TP53 R337H is present, and to predict its outcome. An ongoing pilot study consisting of close monitoring of healthy carriers of the TP53 R337H mutation - siblings and first-degree relatives of known affected cases - aims at the early detection of ACTs and an improvement of the cure rate.

  5. Detection of cavitation inception by acoustic technique in centrifugal pumps for nuclear application

    International Nuclear Information System (INIS)

    Prakash, V.; Prabhakar, R.; Rao, A.S.L.K.; Kale, R.D.

    1994-01-01

    The primary centrifugal pumps in a pool type reactor like the proposed Prototype Fast Breeder Reactor (PFBR) are required to operate at low values of available net positive suction head due to the limited submergence available in the pool. Pump hydraulics are designed to ensure that there is no cavitation or only minimum cavitation in the pump impeller in order to minimise long term erosion damage. Rigorous cavitation tests are usually carried out during development and final testing phase and a promising cavitation detection technique lies in acoustic noise measurements on the pump. As part of PFBR pump development programme, cavitation noise measurements were initially carried out on an experimental sodium pump in a water rig to establish detection procedures. Recently cavitation noise measurements were carried out on a 1/3 scale model impeller of PFBR pump along with visual observation of impeller passages to establish a correlation between visual and acoustic technique. Accelerometer responding to structure borne noise seems to give the best result. (author). 4 refs., 6 figs

  6. Non-invasive vascular imaging: assessing tumour vascularity

    International Nuclear Information System (INIS)

    Delorme, S.; Knopp, M.V.

    1998-01-01

    Non-invasive assessment of vascularity is a new diagnostic approach to characterise tumours. Vascular assessment is based on the pathophysiology of tumour angiogenesis and its diagnostic implications for tumour biology, prognosis and therapy response. Two current techniques investigating vascular features in addition to morphology are Doppler ultrasonography and contrast-enhanced MRI. Diagnostic differentiation has been shown to be possible with Doppler, and a high degree of observed vascularity could be linked to an aggressive course of the disease. Dynamic MRI using gadolinium chelates is already used clinically to detect and differentiate tumours. The histological correlation shows that capillary permeability is increased in malignant tumours and is the best criterion for differentiation from benign processes. Permeability and perfusion factors seem to be more diagnostic than overall vessel density. New clinical applications are currently being established for therapy monitoring. Further instrumental developments will bring harmonic imaging in Doppler, and faster imaging techniques, higher spatial resolution and novel pharmacokinetic concepts in MRI. Upcoming contrast agents for both Doppler and MRI will further improve estimation of intratumoural blood volume and vascular permeability. (orig.)

  7. Towards an Automated Acoustic Detection System for Free Ranging Elephants.

    Science.gov (United States)

    Zeppelzauer, Matthias; Hensman, Sean; Stoeger, Angela S

    The human-elephant conflict is one of the most serious conservation problems in Asia and Africa today. The involuntary confrontation of humans and elephants claims the lives of many animals and humans every year. A promising approach to alleviate this conflict is the development of an acoustic early warning system. Such a system requires the robust automated detection of elephant vocalizations under unconstrained field conditions. Today, no system exists that fulfills these requirements. In this paper, we present a method for the automated detection of elephant vocalizations that is robust to the diverse noise sources present in the field. We evaluate the method on a dataset recorded under natural field conditions to simulate a real-world scenario. The proposed method outperformed existing approaches and robustly and accurately detected elephants. It thus can form the basis for a future automated early warning system for elephants. Furthermore, the method may be a useful tool for scientists in bioacoustics for the study of wildlife recordings.

  8. DETECTION OF DRUGSTORE BEETLES IN 9975 PACKAGES USING ACOUSTIC EMISSIONS

    Energy Technology Data Exchange (ETDEWEB)

    Shull, D.

    2013-03-04

    This report documents the initial feasibility tests performed using a commercial acoustic emission instrument for the purpose of detecting beetles in Department of Energy 9975 shipping packages. The device selected for this testing was a commercial handheld instrument and probe developed for the detection of termites, weevils, beetles and other insect infestations in wooden structures, trees, plants and soil. The results of two rounds of testing are presented. The first tests were performed by the vendor using only the hand-held instrument’s indications and real-time operator analysis of the audio signal content. The second tests included hands-free positioning of the instrument probe and post-collection analysis of the recorded audio signal content including audio background comparisons. The test results indicate that the system is promising for detecting the presence of drugstore beetles, however, additional work would be needed to improve the ease of detection and to automate the signal processing to eliminate the need for human interpretation. Mechanisms for hands-free positioning of the probe and audio background discrimination are also necessary for reliable detection and to reduce potential operator dose in radiation environments.

  9. Detection of Volatile Organics Using a Surface Acoustic Wave Array System

    International Nuclear Information System (INIS)

    ANDERSON, LAWRENCE F.; BARTHOLOMEW, JOHN W.; CERNOSEK, RICHARD W.; COLBURN, CHRISTOPHER W.; CROOKS, R.M.; MARTINEZ, R.F.; OSBOURN, GORDON C.; RICCO, A.J.; STATON, ALAN W.; YELTON, WILLIAM G.

    1999-01-01

    A chemical sensing system based on arrays of surface acoustic wave (SAW) delay lines has been developed for identification and quantification of volatile organic compounds (VOCs). The individual SAW chemical sensors consist of interdigital transducers patterned on the surface of an ST-cut quartz substrate to launch and detect the acoustic waves and a thin film coating in the SAW propagation path to perturb the acoustic wave velocity and attenuation during analyte sorption. A diverse set of material coatings gives the sensor arrays a degree of chemical sensitivity and selectivity. Materials examined for sensor application include the alkanethiol-based self-assembled monolayer, plasma-processed films, custom-synthesized conventional polymers, dendrimeric polymers, molecular recognition materials, electroplated metal thin films, and porous metal oxides. All of these materials target a specific chemical fi.mctionality and the enhancement of accessible film surface area. Since no one coating provides absolute analyte specificity, the array responses are further analyzed using a visual-empirical region-of-influence (VERI) pattern recognition algorithm. The chemical sensing system consists of a seven-element SAW array with accompanying drive and control electronics, sensor signal acquisition electronics, environmental vapor sampling hardware, and a notebook computer. Based on data gathered for individual sensor responses, greater than 93%-accurate identification can be achieved for any single analyte from a group of 17 VOCs and water

  10. Detection of Volatile Organics Using a Surface Acoustic Wave Array System

    Energy Technology Data Exchange (ETDEWEB)

    ANDERSON, LAWRENCE F.; BARTHOLOMEW, JOHN W.; CERNOSEK, RICHARD W.; COLBURN, CHRISTOPHER W.; CROOKS, R.M.; MARTINEZ, R.F.; OSBOURN, GORDON C.; RICCO, A.J.; STATON, ALAN W.; YELTON, WILLIAM G.

    1999-10-14

    A chemical sensing system based on arrays of surface acoustic wave (SAW) delay lines has been developed for identification and quantification of volatile organic compounds (VOCs). The individual SAW chemical sensors consist of interdigital transducers patterned on the surface of an ST-cut quartz substrate to launch and detect the acoustic waves and a thin film coating in the SAW propagation path to perturb the acoustic wave velocity and attenuation during analyte sorption. A diverse set of material coatings gives the sensor arrays a degree of chemical sensitivity and selectivity. Materials examined for sensor application include the alkanethiol-based self-assembled monolayer, plasma-processed films, custom-synthesized conventional polymers, dendrimeric polymers, molecular recognition materials, electroplated metal thin films, and porous metal oxides. All of these materials target a specific chemical fi.mctionality and the enhancement of accessible film surface area. Since no one coating provides absolute analyte specificity, the array responses are further analyzed using a visual-empirical region-of-influence (VERI) pattern recognition algorithm. The chemical sensing system consists of a seven-element SAW array with accompanying drive and control electronics, sensor signal acquisition electronics, environmental vapor sampling hardware, and a notebook computer. Based on data gathered for individual sensor responses, greater than 93%-accurate identification can be achieved for any single analyte from a group of 17 VOCs and water.

  11. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    Directory of Open Access Journals (Sweden)

    Tongzhi Zhang

    2016-11-01

    Full Text Available We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad / ( m ⋅ Pa . A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work.

  12. Steam leak detection in advance reactors via acoustics method

    International Nuclear Information System (INIS)

    Singh, Raj Kumar; Rao, A. Rama

    2011-01-01

    Highlights: → Steam leak detection system is developed to detect any leak inside the reactor vault. → The technique uses leak noise frequency spectrum for leak detection. → Testing of system and method to locate the leak is also developed and discussed in present paper. - Abstract: Prediction of LOCA (loss of coolant activity) plays very important role in safety of nuclear reactor. Coolant is responsible for heat transfer from fuel bundles. Loss of coolant is an accidental situation which requires immediate shut down of reactor. Fall in system pressure during LOCA is the trip parameter used for initiating automatic reactor shut down. However, in primary heat transport system operating in two phase regimes, detection of small break LOCA is not simple. Due to very slow leak rates, time for the fall of pressure is significantly slow. From reactor safety point of view, it is extremely important to find reliable and effective alternative for detecting slow pressure drop in case of small break LOCA. One such technique is the acoustic signal caused by LOCA in small breaks. In boiling water reactors whose primary heat transport is to be driven by natural circulation, small break LOCA detection is important. For prompt action on post small break LOCA, steam leak detection system is developed to detect any leak inside the reactor vault. The detection technique is reliable and plays a very important role in ensuring safety of the reactor. Methodology developed for steam leak detection is discussed in present paper. The methods to locate the leak is also developed and discussed in present paper which is based on analysis of the signal.

  13. Acoustic Detection of Faults and Degradation in a High-Bypass Turbofan Engine during VIPR Phase III Testing

    Science.gov (United States)

    Boyle, Devin K.

    2017-01-01

    The Vehicle Integrated Propulsion Research (VIPR) Phase III project was executed at Edwards Air Force Base, California, by the National Aeronautics and Space Administration and several industry, academic, and government partners in the summer of 2015. One of the research objectives was to use external radial acoustic microphone arrays to detect changes in the noise characteristics produced by the research engine during volcanic ash ingestion and seeded fault insertion scenarios involving bleed air valves. Preliminary results indicate the successful acoustic detection of suspected degradation as a result of cumulative exposure to volcanic ash. This detection is shown through progressive changes, particularly in the high-frequency content, as a function of exposure to greater cumulative quantities of ash. Additionally, detection of the simulated failure of the 14th stage stability bleed valve and, to a lesser extent, the station 2.5 stability bleed valve, to their fully-open fail-safe positions was achieved by means of spectral comparisons between nominal (normal valve operation) and seeded fault scenarios.

  14. Acoustic surveillance techniques for SGU leak monitoring

    International Nuclear Information System (INIS)

    McKnight, J.A.; Rowley, R.; Beesley, M.J.

    1990-01-01

    The paper presents a brief review of the acoustic techniques applicable to the detection of steam generator unit leaks that have been studied in the UK. Before discussion of the acoustic detection methods a reference representation of the required performance as developed in the UK is given. The conclusion is made that preliminary specification for the acoustic leak detection of sodium/water leaks in steam generating units suggests that it will be necessary to detect better than a leak rate of 3 g/s within a few seconds. 10 refs, 12 figs

  15. Acoustic Emission Monitoring of Incipient in Journal Bearings - Part I : Detectability and measurement for bearing damages

    International Nuclear Information System (INIS)

    Yoon, Dong Jin; Kwon, Oh Yang; Chung, Min Hwa; Kim, Kyung Woong

    1994-01-01

    In contrast to the machinery using rolling element bearings, systems with journal bearings generally operate in large scale and under severe loading condition such as steam generator turbines and internal combustion engines. Failure of the bearings in these machinery can result in the system breakdown. To avoid the time consuming repair and considerable economic loss, the detection of incipient failure in journal bearings becomes very important. In this experimental approach, acoustic emission monitoring is applied to the detection of incipient failure caused by several types of abnormal operating condition most probable in the journal bearing systems. It has been known that the intervention of foreign materials, insufficient lubrication and misassembly etc. are principal factors to cause bearing failure and distress. The experiment was conducted under such designed conditions as hard particles in the lubrication layer, insufficient lubrication, and metallic contact in the simulated journal bearing system. The results showed that acoustic emission could be an effective tool to detect the incipient failure in journal bearings

  16. PET/MRI and PET/CT in advanced gynaecological tumours: initial experience and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Marcelo A.; Schulthess, Gustav von; Veit-Haibach, Patrick [University Hospital Zurich, Department Medical Radiology, Nuclear Medicine, Zurich (Switzerland); University Hospital Zurich, Department Medical Radiology, Diagnostic and Interventional Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Kubik-Huch, Rahel A.; Freiwald-Chilla, Bianka [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); Hauser, Nik [Kantonsspital Baden AG, Department of Gynaecology, Baden (Switzerland); Froehlich, Johannes M. [Guerbet AG, Zurich (Switzerland)

    2015-08-15

    To compare the diagnostic accuracy of PET/MRI and PET/CT for staging and re-staging advanced gynaecological cancer patients as well as identify the potential benefits of each method in such a population. Twenty-six patients with suspicious or proven advanced gynaecological cancer (12 ovarian, seven cervical, one vulvar and four endometrial tumours, one uterine metastasis, and one primary peritoneal cancer) underwent whole-body imaging with a sequential trimodality PET/CT/MR system. Images were analysed regarding primary tumour detection and delineation, loco-regional lymph node staging, and abdominal/extra-abdominal distant metastasis detection (last only by PET/CT). Eighteen (69.2 %) patients underwent PET/MRI for primary staging and eight patients (30.8 %) for re-staging their gynaecological malignancies. For primary tumour delineation, PET/MRI accuracy was statistically superior to PET/CT (p < 0.001). Among the different types of cancer, PET/MRI presented better tumour delineation mainly for cervical (6/7) and endometrial (2/3) cancers. PET/MRI for local evaluation as well as PET/CT for extra-abdominal metastases had therapeutic consequences in three and one patients, respectively. PET/CT detected 12 extra-abdominal distant metastases in 26 patients. PET/MRI is superior to PET/CT for primary tumour delineation. No differences were found in detection of regional lymph node involvement and abdominal metastases detection. (orig.)

  17. Acoustic Characterization of Mesoscale Objects

    Energy Technology Data Exchange (ETDEWEB)

    Chinn, D; Huber, R; Chambers, D; Cole, G; Balogun, O; Spicer, J; Murray, T

    2007-03-13

    This report describes the science and engineering performed to provide state-of-the-art acoustic capabilities for nondestructively characterizing mesoscale (millimeter-sized) objects--allowing micrometer resolution over the objects entire volume. Materials and structures used in mesoscale objects necessitate the use of (1) GHz acoustic frequencies and (2) non-contacting laser generation and detection of acoustic waves. This effort demonstrated that acoustic methods at gigahertz frequencies have the necessary penetration depth and spatial resolution to effectively detect density discontinuities, gaps, and delaminations. A prototype laser-based ultrasonic system was designed and built. The system uses a micro-chip laser for excitation of broadband ultrasonic waves with frequency components reaching 1.0 GHz, and a path-stabilized Michelson interferometer for detection. The proof-of-concept for mesoscale characterization is demonstrated by imaging a micro-fabricated etched pattern in a 70 {micro}m thick silicon wafer.

  18. Intracapillary HbO2 saturations in murine tumours and human tumour xenografts measured by cryospectrophotometry: relationship to tumour volume, tumour pH and fraction of radiobiologically hypoxic cells.

    Science.gov (United States)

    Rofstad, E K; Fenton, B M; Sutherland, R M

    1988-05-01

    Frequency distributions for intracapillary HbO2 saturation were determined for two murine tumour lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI) using a cryospectrophotometric method. The aim was to search for possible relationships between HbO2 saturation status and tumour volume, tumour pH and fraction of radiobiologically hypoxic cells. Tumour pH was measured by 31P NMR spectroscopy. Hypoxic fractions were determined from cell survival curves for tumours irradiated in vivo and assayed in vitro. Tumours in the volume range 100-4000 mm3 were studied and the majority of the vessels were found to have HbO2 saturations below 10%. The volume-dependence of the HbO2 frequency distributions differed significantly among the four tumour lines; HbO2 saturation status decreased with increasing tumour volume for the KHT, RIF-1 and MLS lines and was independent of tumour volume for the OWI line. The data indicated that the rate of decrease in HbO2 saturation status during tumour growth was related to the rate of development of necrosis. The volume-dependence of tumour pH was very similar to that of the HbO2 saturation status for all tumour lines. Significant correlations were therefore found between HbO2 saturation status and tumour pH, both within tumour lines and across the four tumour lines, reflecting that the volume-dependence of both parameters probably was a compulsory consequence of reduced oxygen supply conditions during tumour growth. Hypoxic fraction increased during tumour growth for the KHT, RIF-1 and MLS lines and was volume-independent for the OWI line, suggesting a relationship between HbO2 saturation status and hypoxic fraction within tumour lines. However, there was no correlation between these two parameters across the four tumour lines, indicating that the hypoxic fraction of a tumour is not determined only by the oxygen supply conditions; other parameters may also be important, e.g. oxygen diffusivity, rate of oxygen

  19. ISAT: The mega-fauna acoustic tracking system

    KAUST Repository

    De la Torre, Pedro; Smith, Egan Lloyd; Sancheti, Ajay; Salama, Khaled N.; Berumen, Michael L.

    2013-01-01

    The acoustic tracking module of the Integrated Satellite and Acoustic Telemetry (iSAT) system is discussed in detail. iSAT is capable of detecting the relative direction of an acoustic source by measuring the order of arrival (OOA) of the acoustic

  20. Clinical multi-colour fluorescence imaging of malignant tumours - initial experience

    International Nuclear Information System (INIS)

    Svanberg, K.; Wang, I.; Montan, S.; Andersson-Engels, S.; Svanberg, S.; Lund Inst. of Technology

    1998-01-01

    The purpose of this study was to present a new technique for non-invasive tumour detection based on tissue fluorescence imaging. A clinically adapted multi-colour fluorescence system was employed in the real-time imaging of malignant tumours of the skin, breast, head and neck region, and urinary bladder. Tumour detection was based on the contrast displayed in fluorescence between normal and malignant tissue, related to the selective uptake of tumour-marking agents and natural chromophore differences between various tissues. In order to demarcate basal cell carcinomas of the skin, ALA was applied topically 4-6 h before the fluorescence investigation. For urinary bladder tumour visualisation, ALA was instilled into the bladder 1-2 h prior to the study. Malignant and premalignant lesions in the head and neck region were imaged after i.v. injection of HPD (Photofrin). The tumour imaging system was coupled to an endoscope. Fluorescence light emission from the tissue surface was induced with 100-ns-long optical pulses at 390 nm, generated from a frequency-doubled alexandrite laser. With the use of special image-splitting optics, the tumour fluorescence, intensified in a micro-channel plate, was imaged in 3 selected wavelength bands. These 3 images were processed together to form a new optimised-contrast image of the tumour. This image, updated at a rate of about 3 frames/s was mixed with a normal colour video image of the tissue. A clear demarcation from normal surrounding tissue was found during in vivo measurements of superficial bladder carcinoma, basal cell carcinoma of the skin, and leukoplakia with dysplasia of the lip, and in vitro investigations of resected breast cancer. (orig./MG)

  1. Tumour detection and localization using 99Tcm-labelled OV-TL 3 Fab' in patients suspected of ovarian cancer

    International Nuclear Information System (INIS)

    Tibben, J.G.; Massuger, L.F.A.G.; Claessens, R.A.M.J.; Schijf, C.P.T.; Strijk, S.P.; Kenemans, P.; Corstens, F.H.M.; Pak, K.Y.

    1992-01-01

    Fab' fragments of the monoclonal antibody OV-TL 3, that recognizes an ovarian carcinoma-associated antigen (OA3), were labelled with 99 Tc m using D-glucarate as a ligand. Twenty patients suspected of having primary or recurrent ovarian cancer received intravenously 1 mg of the Fab' labelled with 740 MBq 99 Tc m . Both planar and single photon emission computed tomographic (SPECT) scintigraphy were performed up to 30 h after intravenous infusion. Imaging results were compared with X-ray computed tomography (CT), ultrasonography (US) and CA 125 serum level. Blood clearance was fast (t 1/2 of 9.5 h). Thirty-seven per cent of the injected dose (% ID) was excreted in the urine within the first 24 h, whereas 7% ID was excreted in the 24 h faeces. In one patient with an OA3 negative ovarian carcinoma, radioimmunoscintigraphy (RIS) did not visualize the tumour. In two other patients a benign ovarian cyst was found, also showing no elevated uptake. In 13 out of 17 patients ovarian cancer lesions were detected with RIS, whereas CT and US detected lesions in, respectively, 15 and 12 patients. Of 36 surgically defined tumour deposits larger than 1 cm in diameter, 53% were detected and localized with RIS, whereas CT and US detected 61 and 40%, respectively. Radioimmunoscintigraphy with 99 Tc m -OV-TL 3 Fab' is less distressing for the patients but the overall imaging performance is not improved when compared with 111 In-OV-TL 3 F(ab') 2 . (Author)

  2. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract.

    Science.gov (United States)

    Hubalewska-Dydejczyk, A; Kulig, J; Szybinski, P; Mikolajczak, R; Pach, D; Sowa-Staszczak, A; Fröss-Baron, K; Huszno, B

    2007-10-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue "marked" by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [(99m)Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [(99m)Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [(99m)Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [(99m)Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology.

  3. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Hubalewska-Dydejczyk, A.; Kulig, J.; Szybinski, P.; Mikolajczak, R.; Pach, D.; Sowa-Staszczak, A.; Froess-Baron, K.; Huszno, B.

    2007-01-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue ''marked'' by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [ 99m Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [ 99m Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [ 99m Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [ 99m Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology. (orig.)

  4. A Miniaturized QEPAS Trace Gas Sensor with a 3D-Printed Acoustic Detection Module

    Directory of Open Access Journals (Sweden)

    Xiaotao Yang

    2017-07-01

    Full Text Available A 3D printing technique was introduced to a quartz-enhanced photoacoustic spectroscopy (QEPAS sensor and is reported for the first time. The acoustic detection module (ADM was designed and fabricated using the 3D printing technique and the ADM volume was compressed significantly. Furthermore, a small grin lens was used for laser focusing and facilitated the beam adjustment in the 3D-printed ADM. A quartz tuning fork (QTF with a low resonance frequency of 30.72 kHz was used as the acoustic wave transducer and acetylene (C2H2 was chosen as the analyte. The reported miniaturized QEPAS trace gas sensor is useful in actual sensor applications.

  5. Wideband excitation in nonlinear vibro-acoustic modulation for damage detection

    Science.gov (United States)

    Klepka, A.; Adamczyk, M.; Pieczonka, L.; Staszewski, W. J.

    2016-04-01

    The paper discusses the use of wideband excitation in nonlinear vibro-acoustic modulation technique (VAM) used for damage detection. In its original form, two mono-harmonic signals (low and high frequency) are used for excitation. The low frequency excitation is typically selected based on a modal analysis test and high frequency excitation is selected arbitrarily in the ultrasonic frequency range. This paper presents a different approach with use of wideband excitation signals. The proposed approach gives the possibility to simplify the testing procedure by omitting the modal test used to determine the value of low frequency excitation. Simultaneous use of wideband excitation for high frequency solves the ambiguity related to the selection of the frequency of acoustic wave. Broadband excitation signals require, however, more elaborate signal processing methods to determine the intensity of modulation for a given bandwidth. The paper discusses the proposed approach and the related signal processing procedure. Experimental validation of the proposed technique is performed on a laminated composite plate with a barely visible impact damage that was generated in an impact test. Piezoceramic actuators are used for vibration excitation and a scanning laser vibrometer is used for noncontact data acquisition.

  6. Monoclonal antibodies for radioimmunodetection of tumours and for targeting

    International Nuclear Information System (INIS)

    Baldwin, R.W.; Embleton, M.J.; Pimm, M.V.

    1983-01-01

    A monoclonal antibody 791T/36 prepared against human osteogenic sarcoma has been used to detect primary and metastatic colorectal carcinomas by external imaging of patients following injection of 131 I-labelled antibody. In 10 of 11 patients radiolabelled 791T/36 antibody localized in tumours, the tumour/non tumour ratio of radioactivity ranging from 1.5:1 to 8.1. 791T/36 antibody was also evaluated for its potential for targeting anti-tumour agents including cytotoxic drugs (Vindesine) and immunomodulating agents (interferon). Vindesine-791T/36 conjugates were preferentially cytotoxic in vitro for target cells expressing the 791T/36 anti-body defined antigen. Also interferon conjugated to 791T/36 antibody, like free interferon activated peripheral blood natural killer cell activity. These in vitro tests together with related studies on antibody localization in vivo indicate the potential of monoclonal antibody targeting of anti-tumour agents

  7. MRI of intraspinal nerve sheath tumours presenting with sciatica

    International Nuclear Information System (INIS)

    Loke, T.K.L.; Chan, C.S.; Ma, H.T.G.; Ward, S.C.; Metreweli, C.

    1995-01-01

    The magnetic resonance imaging (MRI) characteristics of 14 intraspinal nerve sheath tumours (NST) presenting with sciatica were reviewed. The group comprised seven schwannomas, six neurofibromas and one perineuroma. The tumours were either iso- or hypointense with respect to spinal cord on T1-weighted (T1W) images; almost all tumours were hyperintense compared with spinal cord on T2-weighted (T2W) images. The tumours were all detectable on unenhanced T1 W images. Nine NST were scanned following Gadolinium-Diethylenetriamine penta acetic acid (DTPA) injection and all showed intense enhancement. This aids differentiation from sequestrated disc fragments. Tumours were more likely to show homogeneous enhancement unless they were recurrent tumours. Rim enhancement occurs more commonly in schwannomas and this can be used to differentiate these from neurofibromas. It is estimated that on unenhanced images, schwannomas cannot be distinguished from neurofibromas. Four tumours occurred at T1 1-T12. There was poor correlation of the site of the lesion with the clinical findings. It is recommended that the MRI studies in patients with sciatica should include the lower thoracic region especially if no protruded disc was found in the lumbar region. 15 refs., 4 figs

  8. MRI of intraspinal nerve sheath tumours presenting with sciatica

    Energy Technology Data Exchange (ETDEWEB)

    Loke, T.K.L.; Chan, C.S. [United Christian Hospital (Hong Kong). Dept. of Diagnostic Radiology; Ma, H.T.G. [St Teresa`s Hospital, Kowloon (Hong Kong). MRI and CT scanning Dept.; Ward, S.C.; Metreweli, C. [Prince of wales Hospital, New Territories (Hong Kong). Dept. of Diagnostic Radiology

    1995-08-01

    The magnetic resonance imaging (MRI) characteristics of 14 intraspinal nerve sheath tumours (NST) presenting with sciatica were reviewed. The group comprised seven schwannomas, six neurofibromas and one perineuroma. The tumours were either iso- or hypointense with respect to spinal cord on T1-weighted (T1W) images; almost all tumours were hyperintense compared with spinal cord on T2-weighted (T2W) images. The tumours were all detectable on unenhanced T1 W images. Nine NST were scanned following Gadolinium-Diethylenetriamine penta acetic acid (DTPA) injection and all showed intense enhancement. This aids differentiation from sequestrated disc fragments. Tumours were more likely to show homogeneous enhancement unless they were recurrent tumours. Rim enhancement occurs more commonly in schwannomas and this can be used to differentiate these from neurofibromas. It is estimated that on unenhanced images, schwannomas cannot be distinguished from neurofibromas. Four tumours occurred at T1 1-T12. There was poor correlation of the site of the lesion with the clinical findings. It is recommended that the MRI studies in patients with sciatica should include the lower thoracic region especially if no protruded disc was found in the lumbar region. 15 refs., 4 figs.

  9. A New Acoustic Emission Sensor Based Gear Fault Detection Approach

    Directory of Open Access Journals (Sweden)

    Junda Zhu

    2013-01-01

    Full Text Available In order to reduce wind energy costs, prognostics and health management (PHM of wind turbine is needed to ensure the reliability and availability of wind turbines. A gearbox is an important component of a wind turbine. Therefore, developing effective gearbox fault detection tools is important to the PHM of wind turbine. In this paper, a new acoustic emission (AE sensor based gear fault detection approach is presented. This approach combines a heterodyne based frequency reduction technique with time synchronous average (TSA and spectrum kurtosis (SK to process AE sensor signals and extract features as condition indictors for gear fault detection. Heterodyne technique commonly used in communication is first employed to preprocess the AE signals before sampling. By heterodyning, the AE signal frequency is down shifted from several hundred kHz to below 50 kHz. This reduced AE signal sampling rate is comparable to that of vibration signals. The presented approach is validated using seeded gear tooth crack fault tests on a notational split torque gearbox. The approach presented in this paper is physics based and the validation results have showed that it could effectively detect the gear faults.

  10. 99mTc-EDDA/HYNIC-octreotate scintigraphy, an efficient method for the detection and staging of carcinoid tumours: results of 3 years' experience.

    Science.gov (United States)

    Hubalewska-Dydejczyk, A; Fröss-Baron, K; Mikołajczak, R; Maecke, H R; Huszno, B; Pach, D; Sowa-Staszczak, A; Janota, B; Szybiński, P; Kulig, J

    2006-10-01

    At all stages of the disease, serious difficulties are encountered in the imaging diagnosis of carcinoids. Somatostatin receptor scintigraphy (SRS) holds great promise for detecting primary tumours and metastases. 99mTc-EDDA/HYNIC-octreotate should significantly improve the diagnosis of carcinoids in comparison with 111In-Octreoscan owing to the better affinity for SSR2 and the higher count rate. The aim of this study was to assess the diagnostic efficiency of 99mTc-EDDA/HYNIC-octreotate scintigraphy in the detection and staging of carcinoid tumours. The study population comprised 75 patients (age 48.5+/-15.5 years): 46 with histological confirmation of carcinoid and 29 with suspected disease. 99mTc-EDDA/HYNIC-octreotate (740 MBq) SRS and CT were performed in all patients. Fifteen patients were examined with 111In-Octreoscan. High-quality 99mTc-EDDA/HYNIC-octreotate images were obtained in all cases, with maximum tumour tracer accumulation 4 h p.i. The mean target/non-target ratios for whole body (WB) and SPECT scans were, respectively, as follows: primary lesions: 4.5 and 10.2; metastases: liver, 3.1 and 12.3; abdominal focal lesions, 2.7 and 5.8; lung, 2.7 and 8.3; mediastinum, 3.4 and 7.6; bones, 6.8 and 19.0. 99mTc-EDDA/HYNIC-octreotate WB scans revealed more metastases than 111In-Octreoscan, with better individual separation. 99mTc-EDDA/HYNIC-octreotate SRS revealed new metastatic lesions in seven patients with confirmed carcinoid, and in four with dissemination the primary focus was found. Five patients qualified for radioguided surgery and 11 were referred to 90Y-DOTA-TATE therapy. The sensitivity of SRS in comparison with CT was higher for primary lesions and liver and abdominal lymph node metastases. In the subgroup of patients with suspected neuroendocrine tumours, two duodenal carcinoids, one thymic carcinoid and one ileal carcinoid were found. 99mTc-EDDA/HYNIC-octreotate, with high imaging quality, is an excellent alternative to 111In-Octreoscan for

  11. 99mTc-EDDA/HYNIC-octreotate scintigraphy, an efficient method for the detection and staging of carcinoid tumours: results of 3 years' experience

    International Nuclear Information System (INIS)

    Hubalewska-Dydejczyk, A.; Froess-Baron, K.; Huszno, B.; Pach, D.; Sowa-Staszczak, A.; Mikolajczak, R.; Janota, B.; Maecke, H.R.; Szybinski, P.; Kulig, J.

    2006-01-01

    At all stages of the disease, serious difficulties are encountered in the imaging diagnosis of carcinoids. Somatostatin receptor scintigraphy (SRS) holds great promise for detecting primary tumours and metastases. 99m Tc-EDDA/HYNIC-octreotate should significantly improve the diagnosis of carcinoids in comparison with 111 In-Octreoscan owing to the better affinity for SSR2 and the higher count rate. The aim of this study was to assess the diagnostic efficiency of 99m Tc-EDDA/HYNIC-octreotate scintigraphy in the detection and staging of carcinoid tumours. The study population comprised 75 patients (age 48.5±15.5 years): 46 with histological confirmation of carcinoid and 29 with suspected disease. 99m Tc-EDDA/HYNIC-octreotate (740 MBq) SRS and CT were performed in all patients. Fifteen patients were examined with 111 In-Octreoscan. High-quality 99m Tc-EDDA/HYNIC-octreotate images were obtained in all cases, with maximum tumour tracer accumulation 4 h p.i. The mean target/non-target ratios for whole body (WB) and SPECT scans were, respectively, as follows: primary lesions: 4.5 and 10.2; metastases: liver, 3.1 and 12.3; abdominal focal lesions, 2.7 and 5.8; lung, 2.7 and 8.3; mediastinum, 3.4 and 7.6; bones, 6.8 and 19.0. 99m Tc-EDDA/HYNIC-octreotate WB scans revealed more metastases than 111 In-Octreoscan, with better individual separation. 99m Tc-EDDA/HYNIC-octreotate SRS revealed new metastatic lesions in seven patients with confirmed carcinoid, and in four with dissemination the primary focus was found. Five patients qualified for radioguided surgery and 11 were referred to 90 Y-DOTA-TATE therapy. The sensitivity of SRS in comparison with CT was higher for primary lesions and liver and abdominal lymph node metastases. In the subgroup of patients with suspected neuroendocrine tumours, two duodenal carcinoids, one thymic carcinoid and one ileal carcinoid were found. 99m Tc-EDDA/HYNIC-octreotate, with high imaging quality, is an excellent alternative to 111 In

  12. Increased detectability of somatic changes in the DNA from human tumours after probing with "synthetic" and "genome-derived" hypervariable multilocus probes

    DEFF Research Database (Denmark)

    Lagoda, P J; Seitz, G; Epplen, J T

    1989-01-01

    intensities were observed. Together the probes 33.15 and (CAC)5/(GTG)5 detected deviating fingerprint patterns in 63% of the colorectal carcinomas investigated. In mammary and stomach carcinomas, only 1/11 and 2/11 tumours, respectively, showed differences with either of the three probes, 33.15, (GACA)4...

  13. Nondestructive Online Detection of Welding Defects in Track Crane Boom Using Acoustic Emission Technique

    Directory of Open Access Journals (Sweden)

    Yong Tao

    2014-04-01

    Full Text Available Nondestructive detection of structural component of track crane is a difficult and costly problem. In the present study, acoustic emission (AE was used to detect two kinds of typical welding defects, that is, welding porosity and incomplete penetration, in the truck crane boom. Firstly, a subsidiary test specimen with special preset welding defect was designed and added on the boom surface with the aid of steel plates to get the synchronous deformation of the main boom. Then, the AE feature information of the welding defect could be got without influencing normal operation of equipment. As a result, the rudimentary location analysis can be attained using the linear location method and the two kinds of welding defects can be distinguished clearly using AE characteristic parameters such as amplitude and centroid frequency. Also, through the comparison of two loading processes, we concluded that the signal produced during the first loading process was mainly caused by plastic deformation damage and during the second loading process the stress release and structure friction between sections in welding area are the main acoustic emission sources. Thus, the AE is an available tool for nondestructive online detection of latent welding defects of structural component of track crane.

  14. FAULT DETECTION AND LOCALIZATION IN MOTORCYCLES BASED ON THE CHAIN CODE OF PSEUDOSPECTRA AND ACOUSTIC SIGNALS

    Directory of Open Access Journals (Sweden)

    B. S. Anami

    2013-06-01

    Full Text Available Vehicles produce sound signals with varying temporal and spectral properties under different working conditions. These sounds are indicative of the condition of the engine. Fault diagnosis is a significantly difficult task in geographically remote places where expertise is scarce. Automated fault diagnosis can assist riders to assess the health condition of their vehicles. This paper presents a method for fault detection and location in motorcycles based on the chain code of the pseudospectra and Mel-frequency cepstral coefficient (MFCC features of acoustic signals. The work comprises two stages: fault detection and fault location. The fault detection stage uses the chain code of the pseudospectrum as a feature vector. If the motorcycle is identified as faulty, the MFCCs of the same sample are computed and used as features for fault location. Both stages employ dynamic time warping for the classification of faults. Five types of faults in motorcycles are considered in this work. Observed classification rates are over 90% for the fault detection stage and over 94% for the fault location stage. The work identifies other interesting applications in the development of acoustic fingerprints for fault diagnosis of machinery, tuning of musical instruments, medical diagnosis, etc.

  15. Modelling breast cancer tumour growth for a stable disease population.

    Science.gov (United States)

    Isheden, Gabriel; Humphreys, Keith

    2017-01-01

    Statistical models of breast cancer tumour progression have been used to further our knowledge of the natural history of breast cancer, to evaluate mammography screening in terms of mortality, to estimate overdiagnosis, and to estimate the impact of lead-time bias when comparing survival times between screen detected cancers and cancers found outside of screening programs. Multi-state Markov models have been widely used, but several research groups have proposed other modelling frameworks based on specifying an underlying biological continuous tumour growth process. These continuous models offer some advantages over multi-state models and have been used, for example, to quantify screening sensitivity in terms of mammographic density, and to quantify the effect of body size covariates on tumour growth and time to symptomatic detection. As of yet, however, the continuous tumour growth models are not sufficiently developed and require extensive computing to obtain parameter estimates. In this article, we provide a detailed description of the underlying assumptions of the continuous tumour growth model, derive new theoretical results for the model, and show how these results may help the development of this modelling framework. In illustrating the approach, we develop a model for mammography screening sensitivity, using a sample of 1901 post-menopausal women diagnosed with invasive breast cancer.

  16. Sensitivity and specificity of thallium-201 single-photon emission tomography in the functional detection and differential diagnosis of brain tumours

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, R.A. (Dept. of Nuclear Medicine, Middelheim Hospital, Antwerp (Belgium)); Martin, J.J. (Dept. of Neurology, University Hospital, Antwerp (Belgium) Lab. of Neuropathology, Born-Bunge Foundation, Univ. of Antwerp (Belgium)); Dobbeleir, A. (Dept. of Nuclear Medicine, Middelheim Hospital, Antwerp (Belgium)); Crols, R. (Dept. of Neurology, Middelheim Hospital, Antwerp (Belgium)); Neetens, I. (Dept. of Pathology, Middelheim Hospital, Antwerp (Belgium)); Deyn, P.P. de (Lab. of Neuropathology, Born-Bunge Foundation, Univ. of Antwerp (Belgium) Lab. of Neurochemistry and Behaviour, Born-Bunge Foundation, Univ. of Antwerp (Belgium))

    1994-07-01

    Histologically tumours consisted of astrocytoma stage I or II, astrocytoma stage III, glioblastoma multiforme and oligodendroglioma, brain metastasis, lymphoma, meningioma, pituitary adenoma, pineal tumour, colloid cyst and craniopharyngioma. False-negative studies included pineal tumour, colloid cyst, craniopharyngioma, astrocytomas stage I or II and stage III, oligodendroglioma and metastasis in the brain stem. Additional metastases approximately < 1.5 cm were not detected in two patients and [sup 201]Tl SPET underestimated tumoral extent in one patient suffering from glioblastoma multiforme. A false-positive study was obtained in a patient with skull metastasis. All 15 patients who were finally shown to suffer from ischaemic infarction had a normal SPET study 9-28 days after the onset of symptomatology. Of five patients with haemorrhagic infarction, studied within 2 weeks, four were false-positive. Of six patients with intracranial haemorrhage, studied 9-39 days later, one showed focal [sup 201]Tl accumulation. Two further false-positive studies consisted of angioma and epidural haematoma. Finally, SPET studies were normal in six patients with definite diagnosis of (reactive) gliosis, Binswanger's encephalopathy, postinfectious encephalopathy and multiple sclerosis. In the patient population presented, sensitivity of [sup 201]Tl SPET for supratentorial brain tumours was 71.7% and specificity was 80.9%. Clinical information and control SPET studies in combination with early, 30-min and 3- to 4-h delayed imaging may be expected to improve on these figures. On the other hand it seems that, in addition to tumoral histology, the presence of tumours in the fossa posterior and small volumes contribute to the occurrence of false-negative [sup 201]Tl SPET studies. (orig.)

  17. Acoustic waves and the detectability of first-order phase transitions by eLISA

    Science.gov (United States)

    Weir, David J.

    2017-05-01

    In various extensions of the Standard Model it is possible that the electroweak phase transition was first order. This would have been a violent process, involving the formation of bubbles and associated shock waves. Not only would the collision of these bubbles and shock waves be a detectable source of gravitational waves, but persistent acoustic waves could enhance the signal and improve prospects of detection by eLISA. I summarise the results of a recent campaign to model such a phase transition based on large-scale hydrodynamical simulations, and its implications for the eLISA mission.

  18. Acoustically Induced Vibration of Structures: Reverberant Vs. Direct Acoustic Testing

    Science.gov (United States)

    Kolaini, Ali R.; O'Connell, Michael R.; Tsoi, Wan B.

    2009-01-01

    Large reverberant chambers have been used for several decades in the aerospace industry to test larger structures such as solar arrays and reflectors to qualify and to detect faults in the design and fabrication of spacecraft and satellites. In the past decade some companies have begun using direct near field acoustic testing, employing speakers, for qualifying larger structures. A limited test data set obtained from recent acoustic tests of the same hardware exposed to both direct and reverberant acoustic field testing has indicated some differences in the resulting structural responses. In reverberant acoustic testing, higher vibration responses were observed at lower frequencies when compared with the direct acoustic testing. In the case of direct near field acoustic testing higher vibration responses appeared to occur at higher frequencies as well. In reverberant chamber testing and direct acoustic testing, standing acoustic modes of the reverberant chamber or the speakers and spacecraft parallel surfaces can strongly couple with the fundamental structural modes of the test hardware. In this paper data from recent acoustic testing of flight hardware, that yielded evidence of acoustic standing wave coupling with structural responses, are discussed in some detail. Convincing evidence of the acoustic standing wave/structural coupling phenomenon will be discussed, citing observations from acoustic testing of a simple aluminum plate. The implications of such acoustic coupling to testing of sensitive flight hardware will be discussed. The results discussed in this paper reveal issues with over or under testing of flight hardware that could pose unanticipated structural and flight qualification issues. Therefore, it is of paramount importance to understand the structural modal coupling with standing acoustic waves that has been observed in both methods of acoustic testing. This study will assist the community to choose an appropriate testing method and test setup in

  19. A surface acoustic wave response detection method for passive wireless torque sensor

    Science.gov (United States)

    Fan, Yanping; Kong, Ping; Qi, Hongli; Liu, Hongye; Ji, Xiaojun

    2018-01-01

    This paper presents an effective surface acoustic wave (SAW) response detection method for the passive wireless SAW torque sensor to improve the measurement accuracy. An analysis was conducted on the relationship between the response energy-entropy and the bandwidth of SAW resonator (SAWR). A self-correlation method was modified to suppress the blurred white noise and highlight the attenuation characteristic of wireless SAW response. The SAW response was detected according to both the variation and the duration of energy-entropy ascension of an acquired RF signal. Numerical simulation results showed that the SAW response can be detected even when the signal-to-noise ratio (SNR) is 6dB. The proposed SAW response detection method was evaluated with several experiments at different conditions. The SAW response can be well distinguished from the sinusoidal signal and the noise. The performance of the SAW torque measurement system incorporating the detection method was tested. The obtained repeatability error was 0.23% and the linearity was 0.9934, indicating the validity of the detection method.

  20. Preliminary Study on Acoustic Detection of Faults Experienced by a High-Bypass Turbofan Engine

    Science.gov (United States)

    Boyle, Devin K.

    2014-01-01

    The vehicle integrated propulsion research (VIPR) effort conducted by NASA and several partners provided an unparalleled opportunity to test a relatively low TRL concept regarding the use of far field acoustics to identify faults occurring in a high bypass turbofan engine. Though VIPR Phase II ground based aircraft installed engine testing wherein a multitude of research sensors and methods were evaluated, an array of acoustic microphones was used to determine the viability of such an array to detect failures occurring in a commercially representative high bypass turbofan engine. The failures introduced during VIPR testing included commanding the engine's low pressure compressor (LPC) exit and high pressure compressor (HPC) 14th stage bleed values abruptly to their failsafe positions during steady state

  1. Broadband unidirectional acoustic cloak based on phase gradient metasurfaces with two flat acoustic lenses

    Science.gov (United States)

    Wang, Xiao-Peng; Wan, Le-Le; Chen, Tian-Ning; Song, Ai-Ling; Wang, Fang

    2016-07-01

    Narrow bandwidth and bulky configuration are the main obstacles for the realization and application of invisible cloaks. In this paper, we present an effective method to achieve broadband and thin acoustic cloak by using an acoustic metasurface (AMS). In order to realize this cloak, we use slitted unit cells to design the AMS due to the advantage of less energy loss, broad operation bandwidth, and subwavelength thickness. According to the hyperboloidal phase profile along the AMS, the incident plane waves can be focused at a designed focal spot by the flat lens. Furthermore, broadband acoustic cloak is obtained by combining two identical flat lenses. The incident plane waves are focused at the center point in between of the two lenses by passing through one lens, and then recovered by passing through the other one. However, they cannot reach the cloaked regions in between of the two lenses. The simulation results can verify the non-detectability effect of the acoustic cloak. Our study results provide an available and simple approach to experimentally achieve the acoustic cloak, which can be used in acoustic non-detectability for large objects.

  2. Detection of cavitation vortex in hydraulic turbines using acoustic techniques

    International Nuclear Information System (INIS)

    Candel, I; Ioana, C; Bunea, F; Politehnica University of Bucharest (Romania))" data-affiliation=" (Power Engineering Faculty, Politehnica University of Bucharest (Romania))" >Dunca, G; Politehnica University of Bucharest (Romania))" data-affiliation=" (Power Engineering Faculty, Politehnica University of Bucharest (Romania))" >Bucur, D M; Division Technique Générale, Grenoble (France))" data-affiliation=" (Electricité de France, Division Technique Générale, Grenoble (France))" >Reeb, B; Ciocan, G D

    2014-01-01

    Cavitation phenomena are known for their destructive capacity in hydraulic machineries and are caused by the pressure decrease followed by an implosion when the cavitation bubbles find an adverse pressure gradient. A helical vortex appears in the turbine diffuser cone at partial flow rate operation and can be cavitating in its core. Cavity volumes and vortex frequencies vary with the under-pressure level. If the vortex frequency comes close to one of the eigen frequencies of the turbine, a resonance phenomenon may occur, the unsteady fluctuations can be amplified and lead to important turbine and hydraulic circuit damage. Conventional cavitation vortex detection techniques are based on passive devices (pressure sensors or accelerometers). Limited sensor bandwidths and low frequency response limit the vortex detection and characterization information provided by the passive techniques. In order to go beyond these techniques and develop a new active one that will remove these drawbacks, previous work in the field has shown that techniques based on acoustic signals using adapted signal content to a particular hydraulic situation, can be more robust and accurate. The cavitation vortex effects in the water flow profile downstream hydraulic turbines runner are responsible for signal content modifications. Basic signal techniques use narrow band signals traveling inside the flow from an emitting transducer to a receiving one (active sensors). Emissions of wide band signals in the flow during the apparition and development of the vortex embeds changes in the received signals. Signal processing methods are used to estimate the cavitation apparition and evolution. Tests done in a reduced scale facility showed that due to the increasing flow rate, the signal -- vortex interaction is seen as modifications on the received signal's high order statistics and bandwidth. Wide band acoustic transducers have a higher dynamic range over mechanical elements; the system

  3. MRI of pineal region tumours: relationship between tumours and adjacent structures

    International Nuclear Information System (INIS)

    Satoh, H.; Kurisu, K.

    1995-01-01

    A variety of tumours may arise in the pineal region; accurate diagnosis is important in the selection of treatment and prognosis. A retrospective analysis of the MRI studies of 25 patients with pathologically proven pineal region tumours was performed, focused on the relationship between the tumour and neighbouring structures. Compression of the tectal plate was classified as expansive or invasive, and compression of the corpus callosum as inferior, anterior or posterior. In 10 of the 14 patients (71 %) with germ cell tumours tectal compression was of the invasive type; 8 patients (57 %) had multiple tumours and in 13 (93 %) the tumour margins were irregular. Teratomas were readily diagnosed because of characteristic heterogeneous signal intensity. Pineal cell tumours were differentiated from germ cell tumours by their rounded shape, solid nature, sharp margins, and expansive type of tectal compression. Meningiomas were characterised by their falcotentorial attachments, posterior callosal compression, and a low-intensity rim on T2-weighted images. Gd-DTPA injection enabled clear demonstration of the site and extent of tumour spread and was useful in differentiating cystic and solid components. The appearances described, while not pathognomonic, are helpful in the differential diagnosis of pineal region tumours, and valuable in planning appropriate treatment. (orig.). With 4 figs., 6 tabs

  4. Machine Fault Detection Based on Filter Bank Similarity Features Using Acoustic and Vibration Analysis

    Directory of Open Access Journals (Sweden)

    Mauricio Holguín-Londoño

    2016-01-01

    Full Text Available Vibration and acoustic analysis actively support the nondestructive and noninvasive fault diagnostics of rotating machines at early stages. Nonetheless, the acoustic signal is less used because of its vulnerability to external interferences, hindering an efficient and robust analysis for condition monitoring (CM. This paper presents a novel methodology to characterize different failure signatures from rotating machines using either acoustic or vibration signals. Firstly, the signal is decomposed into several narrow-band spectral components applying different filter bank methods such as empirical mode decomposition, wavelet packet transform, and Fourier-based filtering. Secondly, a feature set is built using a proposed similarity measure termed cumulative spectral density index and used to estimate the mutual statistical dependence between each bandwidth-limited component and the raw signal. Finally, a classification scheme is carried out to distinguish the different types of faults. The methodology is tested in two laboratory experiments, including turbine blade degradation and rolling element bearing faults. The robustness of our approach is validated contaminating the signal with several levels of additive white Gaussian noise, obtaining high-performance outcomes that make the usage of vibration, acoustic, and vibroacoustic measurements in different applications comparable. As a result, the proposed fault detection based on filter bank similarity features is a promising methodology to implement in CM of rotating machinery, even using measurements with low signal-to-noise ratio.

  5. Acoustic system for pipe rupture monitoring and leak detection

    International Nuclear Information System (INIS)

    Herzog, W.; Jonas, H.

    1982-06-01

    As a safety aspect pipe rupture and leakage effects are of particular interest in nuclear power plants where severe consequences for the reactor may result. Counter measures against postulated pipe breaks and leakages in nuclear power plants are necessary whenever the main safety goals: safe shut-down, safe afterheat removal and retention of radioactivity, are endangered. The requirements to be met by a leak detection system depend on the time available for counter actions. If this time is short so that automatic actions are necessary the German safety criteria for nuclear power plants (Criterion 6.1) require two physically diverse signals to be monitored. One fairly obvious possibility of leak detection is to monitor process parameters (pressure, flow). As a diverse signal physical parameters outside the process may be employed: pressure transients temperature, humidity are principally suitable. In practical application, however, it is difficult to predict these parameters by way of calculation in order to establish the required set-point of the monitoring system. Experimental determination is possible only in special cases. A study of several ways of diverse leak detection methods leads to the very promising acoustic method. We investigated experimentally the feasibility of monitoring the sound created by a leakage. Air borne sound as well as body borne sound was analyzed

  6. Unusual presentation of a large pituitary tumour in relation to diving.

    OpenAIRE

    Bakheit, A. M.; Kennedy, P. G.

    1989-01-01

    A case of necrosis of a pituitary tumour occurring in the context of diving is described. The presenting features and subsequent course suggested a brain stem vascular event. The tumour was not detected by routine computerized tomographic scanning, but was identified with magnetic resonance imaging. The possible pathophysiological mechanism is discussed.

  7. TUMOUR VACCINE

    NARCIS (Netherlands)

    Wagner, Ernst; Kircheis, Ralf; Crommelin, D.; Van Slooten, Maaike; Storm, Gert

    1999-01-01

    The invention relates to a tumour vaccine with a tumour antigen base. In addition to a source of tumour antigens, the vaccine contains a release system for the delayed release of the active agent IFN- gamma , the active dose of IFN- gamma being 50 ng to 5 mu g. The IFN- gamma is released over a

  8. Novel Fiber-Optic Ring Acoustic Emission Sensor.

    Science.gov (United States)

    Wei, Peng; Han, Xiaole; Xia, Dong; Liu, Taolin; Lang, Hao

    2018-01-13

    Acoustic emission technology has been applied to many fields for many years. However, the conventional piezoelectric acoustic emission sensors cannot be used in extreme environments, such as those with heavy electromagnetic interference, high pressure, or strong corrosion. In this paper, a novel fiber-optic ring acoustic emission sensor is proposed. The sensor exhibits high sensitivity, anti-electromagnetic interference, and corrosion resistance. First, the principle of a novel fiber-optic ring sensor is introduced. Different from piezoelectric and other fiber acoustic emission sensors, this novel sensor includes both a sensing skeleton and a sensing fiber. Second, a heterodyne interferometric demodulating method is presented. In addition, a fiber-optic ring sensor acoustic emission system is built based on this method. Finally, fiber-optic ring acoustic emission experiments are performed. The novel fiber-optic ring sensor is glued onto the surface of an aluminum plate. The 150 kHz standard continuous sinusoidal signals and broken lead signals are successfully detected by the novel fiber-optic ring acoustic emission sensor. In addition, comparison to the piezoelectric acoustic emission sensor is performed, which shows the availability and reliability of the novel fiber-optic ring acoustic emission sensor. In the future, this novel fiber-optic ring acoustic emission sensor will provide a new route to acoustic emission detection in harsh environments.

  9. Concomitant expression of several peptide receptors in neuroendocrine tumours: molecular basis for in vivo multireceptor tumour targeting

    International Nuclear Information System (INIS)

    Reubi, Jean Claude; Waser, Beatrice

    2003-01-01

    Peptide receptors have been found to represent excellent targets for in vivo cancer diagnosis and therapy. Recent in vitro studies have shown that many cancers can overexpress not only one but several peptide receptors concomitantly. One of the challenges for nuclear medicine in this field in the coming decade will be to take advantage of the co-expression of peptide receptors for multireceptor tumour targeting. In vitro receptor studies can reveal which peptide receptor is overexpressed in which tumour and which receptors are co-expressed in an individual tumour; such knowledge is a prerequisite for successful in vivo development. One group of tumours of particular interest in this respect is the neuroendocrine tumours, which have previously been shown often to express peptide receptors. This review summarises our investigations of the concomitant expression of 13 different peptide receptors, in more than 100 neuroendocrine tumours of the human intestine, pancreas and lung, using in vitro receptor autoradiography with subtype-selective ligands. The incidence and density of the somatostatin receptors sst 1 -sst 5 , the VIP receptors VPAC 1 and VPAC 2 , the CCK 1 and CCK 2 receptors, the three bombesin receptor subtypes BB 1 (NMB receptor), BB 2 (GRP receptor) and BB 3 , and GLP-1 receptors were evaluated. While the presence of VPAC 1 and sst 2 was detected in the majority of these neuroendocrine tumours, the other receptors, more differentially expressed, revealed a characteristic receptor pattern in several tumour types. Ileal carcinoids expressed sst 2 and VPAC 1 receptors in virtually all cases and had CCK 1 , CCK 2 , sst 1 or sst 5 in approximately half of the cases; they were the only tumours of this series to express NMB receptors. Insulinomas were characterised by a very high incidence of GLP-1, CCK 2 and VPAC 1 receptors, with the GLP-1 receptors expressed in a particularly high density; they expressed sst 2 in two-thirds and sst 1 in approximately half of

  10. Low tumour cell content in a lung tumour bank: implications for molecular characterisation.

    Science.gov (United States)

    Goh, Felicia; Duhig, Edwina E; Clarke, Belinda E; McCaul, Elizabeth; Passmore, Linda; Courtney, Deborah; Windsor, Morgan; Naidoo, Rishendren; Franz, Louise; Parsonson, Kylie; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2017-10-01

    Lung cancer encompasses multiple malignant epithelial tumour types, each with specific targetable, potentially actionable mutations, such that precision management mandates accurate tumour typing. Molecular characterisation studies require high tumour cell content and low necrosis content, yet lung cancers are frequently a heterogeneous mixture of tumour and stromal cells. We hypothesised that there may be systematic differences in tumour cell content according to histological subtype, and that this may have implications for tumour banks as a resource for comprehensive molecular characterisation studies in lung cancer. To investigate this, we estimated tumour cell and necrosis content of 4267 samples resected from 752 primary lung tumour specimens contributed to a lung tissue bank. We found that banked lung cancer samples had low tumour cell content (33%) generally, although it was higher in carcinoids (77.5%) than other lung cancer subtypes. Tumour cells comprise a variable and often small component of banked resected tumour samples, and are accompanied by stromal reaction, inflammation, fibrosis, and normal structures. This has implications for the adequacy of unselected tumour bank samples for diagnostic and molecular investigations, and further research is needed to determine whether tumour cell content has a significant impact on analytical results in studies using tissue from tumour bank resources. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  11. Automatic non-destructive three-dimensional acoustic coring system for in situ detection of aquatic plant root under the water bottom

    Directory of Open Access Journals (Sweden)

    Katsunori Mizuno

    2016-05-01

    Full Text Available Digging is necessary to detect plant roots under the water bottom. However, such detection is affected by the transparency of water and the working skills of divers, usually requires considerable time for high-resolution sampling, and always damages the survey site. We developed a new automatic non-destructive acoustic measurement system that visualizes the space under the water bottom, and tested the system in the in situ detection of natural plant roots. The system mainly comprises a two-dimensional waterproof stage controlling unit and acoustic measurement unit. The stage unit was electrically controlled through a notebook personal computer, and the space under the water bottom was scanned in a two-dimensional plane with the stage unit moving in steps of 0.01 m (±0.0001 m. We confirmed a natural plant root with diameter of 0.025–0.030 m in the reconstructed three-dimensional acoustic image. The plant root was at a depth of about 0.54 m and the propagation speed of the wave between the bottom surface and plant root was estimated to be 1574 m/s. This measurement system for plant root detection will be useful for the non-destructive assessment of the status of the space under the water bottom.

  12. Genetic heterogeneity in supratentorial and infratentorial primitive neuroectodermal tumours of the central nervous system.

    Science.gov (United States)

    Inda, M M; Perot, C; Guillaud-Bataille, M; Danglot, G; Rey, J A; Bello, M J; Fan, X; Eberhart, C; Zazpe, I; Portillo, E; Tuñón, T; Martínez-Peñuela, J M; Bernheim, A; Castresana, J S

    2005-12-01

    Medulloblastoma (MB), a kind of infratentorial primitive neuroectodermal tumour (PNET), is the most frequent malignant brain tumour in childhood. In contrast, supratentorial PNET (sPNET) are very infrequent tumours, but they are histologically similar to MB, although they present a worse clinical outcome. We investigated the differences in genetic abnormalities between sPNET and MB. We analysed 20 central PNET (14 MB and six sPNET) by conventional comparative genomic hybridization (CGH) in order to determine whether a different genetic profile for each tumour exists. Isochromosome 17q was detected in four of the 14 MB cases, but not in any sPNET. Gains at 17q and 7 happened more frequently in MB, and those at 1q in sPNET. Losses at chromosome 10 were detected only in MB, while losses at 16p and 19p happened more frequently in sPNET. A new amplification site, on 4q12, was detected in two MB. Central PNET are a heterogeneous group of tumours from the genetic point of view. The present and previous data, together with further results from larger series, might contribute to the establishment of specific treatments for supratentorial and infratentorial PNET.

  13. Acoustic detection of melt particles

    International Nuclear Information System (INIS)

    Costley, R.D. Jr.

    1988-01-01

    The Reactor Safety Research Department at Sandia National Laboratories is investigating a type of Loss of Coolant Accident (LOCA). In this particular type of accident, core meltdown occurs while the pressure within the reactor pressure vessel (RPV) is high. If one of the instrument tube penetrations in the lower head fails, melt particles stream through the cavity and into the containment vessel. This experiment, which simulates this type accident, was performed in the Surtsev Direct Heating Test Facility which is approximately a 1:10 linear scaling of a large dry containment volume. A 1:10 linear scale model of the reactor cavity was placed near the bottom of the Surtsey vessel so that the exit of the cavity was at the vertical centerline of the vessel. A pressure vessel used to create the simulated molten core debris was located at the scaled height of the RPV. In order to better understand how the melt leaves the cavity and streams into the containment an array of five acoustic sensors was placed directly in the path of the melt particles about 30 feet from the exit of the sealed cavity. Highly damped, broadband sensors were chosen to minimize ringing so that individual particle hits could be detected. The goal was to count the signals produced by the individual particle hits to get some idea of how the melt particles left the cavity. This document presents some of the results of the experiment. 9 figs

  14. {sup 18}F-FDG PET/CT for detection of malignant peripheral nerve sheath tumours in neurofibromatosis type 1: tumour-to-liver ratio is superior to an SUV{sub max} cut-off

    Energy Technology Data Exchange (ETDEWEB)

    Salamon, Johannes [University Medical Centre Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); University Hospital Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Veldhoen, Simon [University Medical Centre Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); University Medical Centre Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Apostolova, Ivayla [Otto-von-Guericke University, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Bannas, Peter; Yamamura, Jin; Herrmann, Jochen; Adam, Gerhard; Derlin, Thorsten [University Medical Centre Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Friedrich, Reinhard E. [University Medical Centre Hamburg-Eppendorf, Department of Oral and Maxillofacial Surgery, Hamburg (Germany); Mautner, Victor F. [University Medical Centre Hamburg-Eppendorf, Department of Neurology, Hamburg (Germany)

    2014-02-15

    To evaluate the usefulness of normalising intra-tumour tracer accumulation on {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) to reference tissue uptake for characterisation of peripheral nerve sheath tumours (PNSTs) in neurofibromatosis type 1 (NF1) compared with the established maximum standardised uptake value (SUVmax) cut-off of >3.5. Forty-nine patients underwent FDG PET/CT. Intra-tumour tracer uptake (SUVmax) was normalised to three different reference tissues (tumour-to-liver, tumour-to-muscle and tumour-to-fat ratios). Receiver operating characteristic (ROC) analyses were used out to assess the diagnostic performance. Histopathology and follow-up served as the reference standard. Intra-tumour tracer uptake correlated significantly with liver uptake (r{sub s} = 0.58, P = 0.016). On ROC analysis, the optimum threshold for tumour-to-liver ratio was >2.6 (AUC = 0.9735). Both the SUVmax cut-off value of >3.5 and a tumour-to-liver ratio >2.6 provided a sensitivity of 100 %, but specificity was significantly higher for the latter (90.3 % vs 79.8 %; P = 0.013). In patients with NF1, quantitative {sup 18}F-FDG PET imaging may identify malignant change in neurofibromas with high accuracy. Specificity could be significantly increased by using the tumour-to-liver ratio. The authors recommend further evaluation of a tumour-to-liver ratio cut-off value of >2.6 for diagnostic intervention planning. (orig.)

  15. Immunity to tumour antigens.

    Science.gov (United States)

    Li, Geng; Ali, Selman A; McArdle, Stephanie E B; Mian, Shahid; Ahmad, Murrium; Miles, Amanda; Rees, Robert C

    2005-01-01

    During the last decade, a large number of human tumour antigens have been identified. These antigens are classified as tumour-specific shared antigens, tissue-specific differentiation antigens, overexpressed antigens, tumour antigens resulting from mutations, viral antigens and fusion proteins. Antigens recognised by effectors of immune system are potential targets for antigen-specific cancer immunotherapy. However, most tumour antigens are self-proteins and are generally of low immunogenicity and the immune response elicited towards these tumour antigens is not always effective. Strategies to induce and enhance the tumour antigen-specific response are needed. This review will summarise the approaches to discovery of tumour antigens, the current status of tumour antigens, and their potential application to cancer treatment.

  16. Analysis of acoustic cardiac signals for heart rate variability and murmur detection using nonnegative matrix factorization-based hierarchical decomposition

    DEFF Research Database (Denmark)

    Shah, Ghafoor; Koch, Peter; Papadias, Constantinos B.

    2014-01-01

    The detection of heart rate variability (HRV) via cardiac auscultation examination can be a useful and inexpensive tool which, however, is challenging in the presence of pathological signals and murmurs. The aim of this research is to analyze acoustic cardiac signals for HRV and murmur detection...

  17. Scintigraphic detection of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging

    Energy Technology Data Exchange (ETDEWEB)

    Georgiou, E C; Arkas, A Z; Alevizaki, C C; Gnafakis, N [Evangelismos Hospital, Athens (Greece). Dept. of Endocrinology and Radioisotopes; Evangelismos Hospital, Athens (Greece). Gynaecology Clinic)

    1979-12-01

    Three cases of scintigraphic visualization of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging are presented, i.e. one case of fibrothecoma ('cold' area visualization) and two cases of fibromyoma ('hot' area visualization). It is suggested that this technique may be useful in the preoperative evaluation of gynaecological tumours and their vascularity.

  18. Sci-Thur AM: YIS – 02: Imaging dose distributions through the detection of radiation-induced acoustic waves

    Energy Technology Data Exchange (ETDEWEB)

    Hickling, Susannah; Lei, Hao; Hobson, Maritza; Leger, Pierre; Wang, Xueding; El Naqa, Issam [University of Michigan, McGill University, McGill University , University of Michigan, University of Michigan/McGill University (United States)

    2016-08-15

    Purpose: X-ray acoustic computed tomography (XACT) is an emerging technique that images the dose deposited within an object following linac irradiation by detecting acoustic waves induced via the photoacoustic effect. This work shows that XACT images can be formed in soft-tissue equivalent material and that dosimetric information can be extracted from such images. Methods: Acoustic waves induced in a water tank following irradiation by a 10 MV flattening filter free photon beam were detected with an immersion ultrasound transducer at 60 angles surrounding the radiation field. A back-projection algorithm was used to reconstruct an XACT image from the detected transducer signals. Profiles extracted from XACT images were compared to profiles measured with ion chambers as per the current clinical protocol. Results: XACT images were successfully formed of simple 4 cm × 4 cm and 6 cm × 3 cm fields, as well as of more complicated multi-leaf collimator defined fields. For the 6 cm × 3 cm field, 74% and 87% of the XACT profile points in the 6 cm and 3 cm dimensions, respectively, passed a 7% / 4 mm gamma test when compared to ion chamber measurements. In a complicated puzzle piece shaped field, 86% of the pixels in an extracted profile passed a 7% / 4 mm gamma test. Conclusions: XACT is capable of imaging the dose distribution delivered by a variety of field sizes and shapes in water, and is a viable technique for both water tank and in vivo dosimetry.

  19. Acoustic emission intrusion detector

    International Nuclear Information System (INIS)

    Carver, D.W.; Whittaker, J.W.

    1980-01-01

    An intrusion detector is provided for detecting a forcible entry into a secured structure while minimizing false alarms. The detector uses a piezoelectric crystal transducer to sense acoustic emissions. The transducer output is amplified by a selectable gain amplifier to control the sensitivity. The rectified output of the amplifier is applied to a Schmitt trigger circuit having a preselected threshold level to provide amplitude discrimination. Timing circuitry is provided which is activated by successive pulses from the Schmitt trigger which lie within a selected time frame for frequency discrimination. Detected signals having proper amplitude and frequency trigger an alarm within the first complete cycle time of a detected acoustical disturbance signal

  20. The effects of two counterpropagating surface acoustic wave beams on single electron acoustic charge transport

    International Nuclear Information System (INIS)

    He Jianhong; Guo Huazhong; Song Li; Zhang Wei; Gao Jie; Lu Chuan

    2010-01-01

    We present a comprehensive study of the effects of two counterpropagating surface acoustic waves on the acoustoelectric current of single electron transport devices. A significant improvement in the accuracy of current quantization is achieved as a result of an additional surface acoustic wave beam. The experiments reveal the sinusoidally periodical modulation in the acoustoelectric current characteristic as a function of the relative phase of the two surface acoustic wave beams. Besides, by using standing surface acoustic waves, the acoustoelectric current is detected which we consider as the so-called anomalous acoustoelectric current produced by acoustic wave mechanical deformations. This kind current is contributed to one component of the acoustoelectric current in surface acoustic wave device, which could enable us to establish a more adequate description of acoustoelectric effects on single-electron acoustic charge transport.

  1. Simulation study and guidelines to generate Laser-induced Surface Acoustic Waves for human skin feature detection

    Science.gov (United States)

    Li, Tingting; Fu, Xing; Chen, Kun; Dorantes-Gonzalez, Dante J.; Li, Yanning; Wu, Sen; Hu, Xiaotang

    2015-12-01

    Despite the seriously increasing number of people contracting skin cancer every year, limited attention has been given to the investigation of human skin tissues. To this regard, Laser-induced Surface Acoustic Wave (LSAW) technology, with its accurate, non-invasive and rapid testing characteristics, has recently shown promising results in biological and biomedical tissues. In order to improve the measurement accuracy and efficiency of detecting important features in highly opaque and soft surfaces such as human skin, this paper identifies the most important parameters of a pulse laser source, as well as provides practical guidelines to recommended proper ranges to generate Surface Acoustic Waves (SAWs) for characterization purposes. Considering that melanoma is a serious type of skin cancer, we conducted a finite element simulation-based research on the generation and propagation of surface waves in human skin containing a melanoma-like feature, determine best pulse laser parameter ranges of variation, simulation mesh size and time step, working bandwidth, and minimal size of detectable melanoma.

  2. Hot topics: Signal processing in acoustics

    Science.gov (United States)

    Gaumond, Charles F.

    2005-09-01

    Signal processing in acoustics is a multidisciplinary group of people that work in many areas of acoustics. We have chosen two areas that have shown exciting new applications of signal processing to acoustics or have shown exciting and important results from the use of signal processing. In this session, two hot topics are shown: the use of noiselike acoustic fields to determine sound propagation structure and the use of localization to determine animal behaviors. The first topic shows the application of correlation on geo-acoustic fields to determine the Greens function for propagation through the Earth. These results can then be further used to solve geo-acoustic inverse problems. The first topic also shows the application of correlation using oceanic noise fields to determine the Greens function through the ocean. These results also have utility for oceanic inverse problems. The second topic shows exciting results from the detection, localization, and tracking of marine mammals by two different groups. Results from detection and localization of bullfrogs are shown, too. Each of these studies contributed to the knowledge of animal behavior. [Work supported by ONR.

  3. Heat shock protein expression in canine malignant mammary tumours

    International Nuclear Information System (INIS)

    Romanucci, Mariarita; Marinelli, Alessia; Sarli, Giuseppe; Salda, Leonardo Della

    2006-01-01

    Abnormal levels of Heat Shock Proteins (HSPs) have been observed in many human neoplasms including breast cancer and it has been demonstrated that they have both prognostic and therapeutic implications. In this study, we evaluated immunohistochemical expression of HSPs in normal and neoplastic canine mammary glands and confronted these results with overall survival (OS), in order to understand the role of HSPs in carcinogenesis and to establish their potential prognostic and/or therapeutic value. Immunohistochemical expression of Hsp27, Hsp72, Hsp73 and Hsp90 was evaluated in 3 normal canine mammary glands and 30 malignant mammary tumours (10 in situ carcinomas, 10 invasive carcinomas limited to local structures without identifiable invasion of blood or lymphatic vessels, 10 carcinomas with invasion of blood or lymphatic vessels and/or metastases to regional lymph nodes). A semi-quantitative method was used for the analysis of the results. Widespread constitutive expression of Hsp73 and Hsp90 was detected in normal tissue, Hsp72 appeared to be focally distributed and Hsp27 showed a negative to rare weak immunostaining. In mammary tumours, a significant increase in Hsp27 (P < 0.01), Hsp72 (P < 0.05) and Hsp90 (P < 0.01) expression was observed as well as a significant reduction in Hsp73 (P < 0.01) immunoreactivity compared to normal mammary gland tissue. Hsp27 demonstrated a strong positivity in infiltrating tumour cells and metaplastic squamous elements of invasive groups. High Hsp27 expression also appeared to be significantly correlated to a shorter OS (P = 0.00087). Intense immunolabelling of Hsp72 and Hsp73 was frequently detected in infiltrative or inflammatory tumour areas. Hsp90 expression was high in all tumours and, like Hsp73, it also showed an intense positivity in lymphatic emboli. These results suggest that Hsp27, Hsp72 and Hsp90 are involved in canine mammary gland carcinogenesis. In addition, Hsp27 appears to be implicated in tumour invasiveness and

  4. Autoregressive techniques for acoustic detection of in-sodium water leaks

    International Nuclear Information System (INIS)

    Hayashi, K.

    1997-01-01

    We have been applied a background signal whitening filter built by univariate autoregressive model to the estimation problem of the leak start time and duration. In the 1995 present benchmark stage, we evaluated the method using acoustic signals from real hydrogen or water/steam injection experiments. The results show that the signal processing technique using this filter can detect reliability the leak signals with a sufficient signal-to-noise ratio. Even if the sensor signal contains non-boiling or non-leak high-amplitude pulses, they can be classified by spectral information. Especially, the feature signal made from the time-frequency spectrum of the filtered signal is very sensitive and useful. (author). 8 refs, 14 figs, 6 tabs

  5. Novel Fiber-Optic Ring Acoustic Emission Sensor

    Directory of Open Access Journals (Sweden)

    Peng Wei

    2018-01-01

    Full Text Available Acoustic emission technology has been applied to many fields for many years. However, the conventional piezoelectric acoustic emission sensors cannot be used in extreme environments, such as those with heavy electromagnetic interference, high pressure, or strong corrosion. In this paper, a novel fiber-optic ring acoustic emission sensor is proposed. The sensor exhibits high sensitivity, anti-electromagnetic interference, and corrosion resistance. First, the principle of a novel fiber-optic ring sensor is introduced. Different from piezoelectric and other fiber acoustic emission sensors, this novel sensor includes both a sensing skeleton and a sensing fiber. Second, a heterodyne interferometric demodulating method is presented. In addition, a fiber-optic ring sensor acoustic emission system is built based on this method. Finally, fiber-optic ring acoustic emission experiments are performed. The novel fiber-optic ring sensor is glued onto the surface of an aluminum plate. The 150 kHz standard continuous sinusoidal signals and broken lead signals are successfully detected by the novel fiber-optic ring acoustic emission sensor. In addition, comparison to the piezoelectric acoustic emission sensor is performed, which shows the availability and reliability of the novel fiber-optic ring acoustic emission sensor. In the future, this novel fiber-optic ring acoustic emission sensor will provide a new route to acoustic emission detection in harsh environments.

  6. Acoustic emission intrusion detector

    International Nuclear Information System (INIS)

    Carver, D.W.

    1978-01-01

    In order to improve the security of handling special nuclear materials at the Oak Ridge Y-12 Plant, a sensitive acoustic emission detector has been developed that will detect forcible entry through block or tile walls, concrete floors, or concrete/steel vault walls. A small, low-powered processor was designed to convert the output from a sensitive, crystal-type acoustic transducer to an alarm relay signal for use with a supervised alarm loop. The unit may be used to detect forcible entry through concrete, steel, block, tile, and/or glass

  7. Electrochemotherapy of tumours

    International Nuclear Information System (INIS)

    Sersa, G.; Cemazar, M.; Rudolf, Z.; Miklavcic, D.

    2006-01-01

    Electrochemotherapy consists of chemotherapy followed by local application of electric pulses to the tumour to increase drug delivery into cells. Drug uptake can be increased by electroporation for only those drugs whose transport through the plasma membrane is impeded. Among many drugs that have been tested so far, only bleomycin and cisplatin found their way from preclinical testing to clinical trials. In vitro studies demonstrated several fold increase of their cytotoxicity after electroporation of cells. In vivo, electroporation of tumours after local or systemic administration of either of the drugs, i.e. electrochemotherapy, proved to be an effective antitumour treatment. In preclinical studies on several tumour models, electrochemotherapy either with bleomycin or cisplatin was elaborated and parameters for effective local tumour control were determined. In veterinary medicine, electrochemotherapy also proved to be effective in the treatment of primary tumours in cats, dogs and horses. In human clinical studies, electrochemotherapy was performed on the patients with progressive disease and accessible tumour nodules of different malignancies. All clinical studies demonstrated that electrochemotherapy is an effective treatment for local tumour control in cancer patients. (author)

  8. Concomitant expression of several peptide receptors in neuroendocrine tumours: molecular basis for in vivo multireceptor tumour targeting

    Energy Technology Data Exchange (ETDEWEB)

    Reubi, Jean Claude; Waser, Beatrice [Division of Cell Biology and Experimental Cancer Research, Institute of Pathology, University of Berne, Murtenstrasse 31, PO Box 62, 3010, Berne (Switzerland)

    2003-05-01

    Peptide receptors have been found to represent excellent targets for in vivo cancer diagnosis and therapy. Recent in vitro studies have shown that many cancers can overexpress not only one but several peptide receptors concomitantly. One of the challenges for nuclear medicine in this field in the coming decade will be to take advantage of the co-expression of peptide receptors for multireceptor tumour targeting. In vitro receptor studies can reveal which peptide receptor is overexpressed in which tumour and which receptors are co-expressed in an individual tumour; such knowledge is a prerequisite for successful in vivo development. One group of tumours of particular interest in this respect is the neuroendocrine tumours, which have previously been shown often to express peptide receptors. This review summarises our investigations of the concomitant expression of 13 different peptide receptors, in more than 100 neuroendocrine tumours of the human intestine, pancreas and lung, using in vitro receptor autoradiography with subtype-selective ligands. The incidence and density of the somatostatin receptors sst{sub 1}-sst{sub 5}, the VIP receptors VPAC{sub 1} and VPAC{sub 2}, the CCK{sub 1} and CCK{sub 2} receptors, the three bombesin receptor subtypes BB{sub 1} (NMB receptor), BB{sub 2} (GRP receptor) and BB{sub 3}, and GLP-1 receptors were evaluated. While the presence of VPAC{sub 1} and sst{sub 2} was detected in the majority of these neuroendocrine tumours, the other receptors, more differentially expressed, revealed a characteristic receptor pattern in several tumour types. Ileal carcinoids expressed sst{sub 2} and VPAC{sub 1} receptors in virtually all cases and had CCK{sub 1}, CCK{sub 2}, sst{sub 1} or sst{sub 5} in approximately half of the cases; they were the only tumours of this series to express NMB receptors. Insulinomas were characterised by a very high incidence of GLP-1, CCK{sub 2} and VPAC{sub 1} receptors, with the GLP-1 receptors expressed in a

  9. Gastric Calcifying Fibrous Tumour

    Directory of Open Access Journals (Sweden)

    Tan Attila

    2006-01-01

    Full Text Available Intramucosal gastric tumours are most commonly found to be gastrointestinal stromal tumours or leiomyomas (smooth muscle tumours; however, a variety of other uncommon mesenchymal tumours can occur in the stomach wall. A rare benign calcifying fibrous tumour is reported and the endoscopic appearance, ultrasound findings and morphology are documented. A review of the literature found only two similar cases.

  10. EPR study of the reactions of tumour and normal tissues under ionizing radiation

    International Nuclear Information System (INIS)

    Rikhireva, G.T.; Pulatova, M.K.; Turganov, M.M.; Pal'mina, N.P.; Burlakova, E.B.

    1978-01-01

    Data on the EPR spectrum characteristics of irradiated tissues of tumour-free animals and animals with tumour are presented. Mice of the Csub(3)Hsub(A) line were used in the experiments. Hepatoma was subcutaneously transplanted with the suspension of tumour tissue reduced to fragments. Animals were killed in 6-8 days after transplantation and in the case of tumour-free animals liver was immediately isolated while in the case of animals with tumour isolated were liver and tumour. Tissues cut with scissors were frozen in liquid nitrogen. Tissue samples were exposed to 60 Co at 1 Mrad dose and -196 deg C. On the base of the data it has been concluded: firstly, there are differences between the EPR spectra of normal and tumour tissue samples irradiated at -196 deg C. Asymmetryc signal with Δ H=Ge and g=2.0005 (''tumour signal'') is typical only for the EPR spectra of tumour and liver tissues of the animal with tumour. Thus, in the -author's opinion, irradiation use turns out to be useful for detecting the difference between the normal and tumour tissues. Secondly, ''tumour signal'' intensity changes after ionol incorporation into animal organism, used as a modificator of tissue sensitivity to the irradiation effect

  11. Tetracycline is back. Three-step tetracycline-biotin tumour targeting

    International Nuclear Information System (INIS)

    Salehi, N.; Lichtenstein, M.

    1998-01-01

    Full text: In the 1960s, investigators attempted to use radiolabelled tetracycline for the detection of tumours. This was limited by bone and gastrointestinal uptake. The monoclonal antibody Avidin Biotin technology has been used for 10 years to target tumours. We have improved a novel mechanism using three step targeting, to demonstrate tumour cells in (C57B1/6X balb-c) F1 mice with subcutaneously implanted E-3 thymoma. The three steps were (1) i.p. injection of Biotin Tetracycline conjugate (t:1) ratio, (2) 96 h later Avidin was injected, and (3) 24 h after (2) 99m Tc-CDTPA-Biotin was injected. Avidin has four high affinity (Km 10-15) Biotin binding sites, hence step (2) couples the Avidin to Tetracycline-Biotin in the tumour. The Avidin then provides a high affinity target for the otherwise rapidly urinary excreted 99m Tc-CDTPA-Biotin. Mice were sacrificed 16-24h after (3) by cervical dislocation. Biodistribution of radioactivity tumour to blood, liver, bone and stomach were: T:BL= 7.2, T:LI= 3.35, TBO= 9.65, T:ST= 0.93. The percentage of injected dose/g was T = 4.49%, BL = 0.62%. E-3 Thymoma is a rapid growing tumour. At day 1 (step 1) the tumour size was 0.45 cm, six days later (step 3) each dimension was doubled. Hence, percentage of injected dose per gram is artefactually reduced eight-fold. With a slowly growing tumour using the same method the results may be better. The conclusions reached are that Tetracycline-Biotin 3-stage method of tumour targeting is worthy of further development

  12. On the measurement of high-energetic neutrinos with the IceCube neutrino telescope and with acoustic detection methods

    International Nuclear Information System (INIS)

    Schunck, Matthias

    2011-01-01

    In this thesis, two subjects have been addressed to enhance the detection of astrophysical neutrinos with the existing IceCube neutrino telescope as well as to explore new detection methods, namely the acoustic detection. In the first part of this thesis, the determination of the acoustic attenuation length in South-Pole ice is presented. This is part of a feasibility study to investigate the acoustic neutrino detection as a possibility to enhance the detection of the highest-energy neutrinos. For this, the acoustic properties of the ice have to be known, and the South-Pole Acoustic Test Setup (SPATS) has been built to determine these. The attenuation length is determined using in-situ measurements with SPATS and a retrievable transmitter (pinger), which was deployed in a depth between 190 and 500 m into the water-filled drilling holes. Even though, the unknown angular-dependent sensitivities of the SPATS sensor channels cannot be avoided and are considered as the dominant systematic effect for these measurements. In this thesis, the acoustic attenuation length is calculated by comparing the energy contents of the pinger pulses recorded by the various SPATS sensor channels for different distances between the pinger and the respective channel. The energy was calculated from the Fourier spectra of the pinger pulses for a frequency range between 5 and 35 kHz. The attenuation coefficient is calculated for each channel individually and the weighted mean over the distribution of all considered channels leads to an attenuation length of 264 +52 -37 m. The dependence of the attenuation on both depth and frequency has been investigated, showing no indications for either. In the second part, a new event reconstruction method based on a Top-Down approach is presented. The method has been implemented for the IC40 detector and applied to the muon energy reconstruction. The Top-Down method is based on the direct comparison of single measured events with a large sample of

  13. On the measurement of high-energetic neutrinos with the IceCube neutrino telescope and with acoustic detection methods

    Energy Technology Data Exchange (ETDEWEB)

    Schunck, Matthias

    2011-10-07

    In this thesis, two subjects have been addressed to enhance the detection of astrophysical neutrinos with the existing IceCube neutrino telescope as well as to explore new detection methods, namely the acoustic detection. In the first part of this thesis, the determination of the acoustic attenuation length in South-Pole ice is presented. This is part of a feasibility study to investigate the acoustic neutrino detection as a possibility to enhance the detection of the highest-energy neutrinos. For this, the acoustic properties of the ice have to be known, and the South-Pole Acoustic Test Setup (SPATS) has been built to determine these. The attenuation length is determined using in-situ measurements with SPATS and a retrievable transmitter (pinger), which was deployed in a depth between 190 and 500 m into the water-filled drilling holes. Even though, the unknown angular-dependent sensitivities of the SPATS sensor channels cannot be avoided and are considered as the dominant systematic effect for these measurements. In this thesis, the acoustic attenuation length is calculated by comparing the energy contents of the pinger pulses recorded by the various SPATS sensor channels for different distances between the pinger and the respective channel. The energy was calculated from the Fourier spectra of the pinger pulses for a frequency range between 5 and 35 kHz. The attenuation coefficient is calculated for each channel individually and the weighted mean over the distribution of all considered channels leads to an attenuation length of 264{sup +52} {sub -37} m. The dependence of the attenuation on both depth and frequency has been investigated, showing no indications for either. In the second part, a new event reconstruction method based on a Top-Down approach is presented. The method has been implemented for the IC40 detector and applied to the muon energy reconstruction. The Top-Down method is based on the direct comparison of single measured events with a large sample

  14. Passive acoustic leak detection for sodium cooled fast reactors using hidden Markov models

    Energy Technology Data Exchange (ETDEWEB)

    Riber Marklund, A. [CEA, Cadarache, DEN/DTN/STCP/LIET, Batiment 202, 13108 St Paul-lez-Durance, (France); Kishore, S. [Fast Reactor Technology Group of IGCAR, (India); Prakash, V. [Vibrations Diagnostics Division, Fast Reactor Technology Group of IGCAR, (India); Rajan, K.K. [Fast Reactor Technology Group and Engineering Services Group of IGCAR, (India)

    2015-07-01

    Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970's and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control. (authors)

  15. Effects of entrained gas on the acoustic detection of sodium boiling in a simulated LMFBR fuel bundle

    International Nuclear Information System (INIS)

    Leavell, W.H.; Sides, W.H.

    1975-01-01

    The relationship between acoustic intensity of nucleate boiling and void fraction was studied in a simulated LMFBR fuel bundle. Results indicate that as the void fraction increases the detected intensity of nucleate boiling decreased until it was indistinguishable from background noise. (JWR)

  16. HPV Infection, but Not EBV or HHV-8 Infection, Is Associated with Salivary Gland Tumours

    Directory of Open Access Journals (Sweden)

    Maja Hühns

    2015-01-01

    Full Text Available Benign and malignant salivary gland tumours are clinically heterogeneous and show different histology. Little is known about the role of human herpes virus 8 (HHV-8, Epstein-Barr virus (EBV, and human papillomavirus (HPV infection in salivary gland neoplasms. We investigated the presence of the three viruses in formalin-fixed, paraffin-embedded tissue samples in a cohort of 200 different salivary gland tumours. We performed EBV-LMP-1 and HHV-8 and p16 immunohistochemistry, a specific chip based hybridization assay for detection and typing of HPV and a chromogenic in situ hybridization for EBV analysis. Only one case, a polymorphic low-grade carcinoma, showed HHV-8 expression and one lymphoepithelial carcinoma was infected by EBV. In 17 cases (9% moderate or strong nuclear and cytoplasmic p16 expression was detected. The HPV type was investigated in all of these cases and additionally in 8 Warthin’s tumours. In 19 cases HPV type 16 was detected, mostly in Warthin’s tumour, adenoid cystic carcinoma, and adenocarcinoma NOS. We concluded that HHV-8 infection and EBV infection are not associated with salivary gland cancer, but HPV infection may play a role in these tumour entities.

  17. Tumour-induced osteomalacia.

    Science.gov (United States)

    Minisola, Salvatore; Peacock, Munro; Fukumoto, Seijii; Cipriani, Cristiana; Pepe, Jessica; Tella, Sri Harsha; Collins, Michael T

    2017-07-13

    Tumour-induced osteomalacia (TIO), also known as oncogenic osteomalacia, is a rare paraneoplastic disorder caused by tumours that secrete fibroblast growth factor 23 (FGF23). Owing to the role of FGF23 in renal phosphate handling and vitamin D synthesis, TIO is characterized by decreased renal tubular reabsorption of phosphate, by hypophosphataemia and by low levels of active vitamin D. Chronic hypophosphataemia ultimately results in osteomalacia (that is, inadequate bone mineralization). The diagnosis of TIO is usually suspected when serum phosphate levels are chronically low in the setting of bone pain, fragility fractures and muscle weakness. Locating the offending tumour can be very difficult, as the tumour is often very small and can be anywhere in the body. Surgical removal of the tumour is the only definitive treatment. When the tumour cannot be located or when complete resection is not possible, medical treatment with phosphate salts or active vitamin D is necessary. One of the most promising emerging treatments for unresectable tumours that cause TIO is the anti-FGF23 monoclonal antibody KRN23. The recent identification of a fusion of fibronectin and fibroblast growth factor receptor 1 (FGFR1) as a molecular driver in some tumours not only sheds light on the pathophysiology of TIO but also opens the door to a better understanding of the transcription, translocation, post-translational modification and secretion of FGF23, as well as suggesting approaches to targeted therapy. Further study will reveal if the FGFR1 pathway is also involved in tumours that do not harbour the translocation.

  18. Damage Detection in Railway Prestressed Concrete Sleepers using Acoustic Emission

    Science.gov (United States)

    Clark, A.; Kaewunruen, S.; Janeliukstis, R.; Papaelias, M.

    2017-10-01

    Prestressed concrete sleepers (or railroad ties) are safety-critical elements in railway tracks that distribute the wheel loads from the rails to the track support system. Over a period of time, the concrete sleepers age and deteriorate in addition to experiencing various types of static and dynamic loading conditions, which are attributable to train operations. In many cases, structural cracks can develop within the sleepers due to high intensity impact loads or due to poor track maintenance. Often, cracks of sleepers develop and present at the midspan due to excessive negative bending. These cracks can cause broken sleepers and sometimes called ‘center bound’ problem in railway lines. This paper is the world first to present an application of non-destructive acoustic emission technology for damage detection in railway concrete sleepers. It presents experimental investigations in order to detect center-bound cracks in railway prestressed concrete sleepers. Experimental laboratory testing involves three-point bending tests of four concrete sleepers. Three-point bending tests correspond to a real failure mode, when the loads are not transferred uniformly to the ballast support. It is observed that AE sensing provides an accurate means for detecting the location and magnitude of cracks in sleepers. Sensor location criticality is also highlighted in the paper to demonstrate the reliability-based damage detection of the sleepers.

  19. Adnexal Tumours Of Skin

    Directory of Open Access Journals (Sweden)

    Parate Sanjay N

    1998-01-01

    Full Text Available A total 120 cases of epidermal appendage tumours of skin were analysed and classified according to the classification provided by WHO’. Epidermal appendage tumours accounted for 12.87% of all skin tumours, of which 29.17% were benign and 70.83% were malignant. Most of the tumours (75.83% were in the head and face region. The most common tumour was basal cell epithelioma (55%.

  20. Comparison of radio-telemetric home range analysis and acoustic detection for Little Brown Bat habitat evaluation

    Science.gov (United States)

    Coleman, Laci S.; Ford, W. Mark; Dobony, Christopher A.; Britzke, Eric R.

    2014-01-01

    With dramatic declines of bat populations due to mortality caused by Pseudogymnoascus destructans (White-nose Syndrome), assessing habitat preferences of bats in the northeastern US is now critical to guide the development of regional conservation efforts. In the summer of 2012, we conducted fixed-station simultaneous telemetry to determine nocturnal spatial use and fixed-kernel home-range estimates of available habitat of a Myotis lucifugus (Le Conte) (Little Brown Bat) maternity colony in an artificial bat house. In summers of 2011 and 2012, we also deployed a 52-ha grid of 4 × 4 Anabat acoustic detectors over five 6–8-day sampling periods in various riparian and non-riparian environments in close proximity to the same bat house. The mean telemetry home range of 143 ha for bats (n = 7) completely overlapped the acoustic grid. Rankings of habitats from telemetry data for these 7 bats and 5 additional bats not included in home-range calculations but added for habitat-use measures (n = 13) revealed a higher proportional use of forested riparian habitats than other types at the landscape scale. Pair-wise comparisons of habitats indicated that bats were found significantly closer to forested riparian habitats and forests than to open water, developed areas, fields, shrublands, or wetland habitats at the landscape scale. Acoustic sampling showed that naïve occupancy was 0.8 and 0.6 and mean nightly detection probabilities were 0.23 and 0.08 at riparian and non-riparian sites, respectively. Our findings suggest that Little Brown Bats select forested riparian and forested habitats for foraging at the landscape scale but may be most easily detected acoustically at riparian sites when a simple occupancy determination for an area is required.

  1. Signal processing techniques for the acoustic detection of boiling in LMFBRs: preliminary results of an IAEA collaborative research programme

    International Nuclear Information System (INIS)

    Macleod, I.D.

    1988-01-01

    A specialist meeting organised by the International Working Group on Fast Reactors (IWGFR) of the International Atomic Energy Agency (IAEA) was held at Chester in the United Kingdom in 1981 to discuss techniques for the detection of acoustic noise from boiling. This meeting recommended that a benchmark test should be carried out to evaluate and compare signal processing methods for use in the detection of the acoustic noise produced by boiling sodium. In response to this recommendation the IAEA set up a collaborative research programme to examine and compare the processing techniques used in the laboratories of member countries. Eight laboratories in six countries have taken part in the programme which will be completed in 1988. This paper summarises the results obtained so far. (author)

  2. Detection of bioagents using a shear horizontal surface acoustic wave biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Larson, Richard S; Hjelle, Brian; Hall, Pam R; Brown, David C; Bisoffi, Marco; Brozik, Susan M; Branch, Darren W; Edwards, Thayne L; Wheeler, David

    2014-04-29

    A biosensor combining the sensitivity of surface acoustic waves (SAW) generated at a frequency of 325 MHz with the specificity provided by antibodies and other ligands for the detection of viral agents. In a preferred embodiment, a lithium tantalate based SAW transducer with silicon dioxide waveguide sensor platform featuring three test and one reference delay lines was used to adsorb antibodies directed against Coxsackie virus B4 or the negative-stranded category A bioagent Sin Nombre virus (SNV). Rapid detection of increasing concentrations of viral particles was linear over a range of order of magnitude for both viruses, and the sensor's selectivity for its target was not compromised by the presence of confounding Herpes Simplex virus type 1 The biosensor was able to delect SNV at doses lower than the load of virus typically found in a human patient suffering from hantavirus cardiopulmonary syndrome (HCPS).

  3. Detection of bioagents using a shear horizontal surface acoustic wave biosensor

    Science.gov (United States)

    Larson, Richard S; Hjelle, Brian; Hall, Pam R; Brown, David C; Bisoffi, Marco; Brozik, Susan M; Branch, Darren W; Edwards, Thayne L; Wheeler, David

    2014-04-29

    A biosensor combining the sensitivity of surface acoustic waves (SAW) generated at a frequency of 325 MHz with the specificity provided by antibodies and other ligands for the detection of viral agents. In a preferred embodiment, a lithium tantalate based SAW transducer with silicon dioxide waveguide sensor platform featuring three test and one reference delay lines was used to adsorb antibodies directed against Coxsackie virus B4 or the negative-stranded category A bioagent Sin Nombre virus (SNV). Rapid detection of increasing concentrations of viral particles was linear over a range of order of magnitude for both viruses, and the sensor's selectivity for its target was not compromised by the presence of confounding Herpes Simplex virus type 1 The biosensor was able to delect SNV at doses lower than the load of virus typically found in a human patient suffering from hantavirus cardiopulmonary syndrome (HCPS).

  4. Bat detective—Deep learning tools for bat acoustic signal detection

    Science.gov (United States)

    Barlow, Kate E.; Firman, Michael; Freeman, Robin; Harder, Briana; Kinsey, Libby; Mead, Gary R.; Newson, Stuart E.; Pandourski, Ivan; Russ, Jon; Szodoray-Paradi, Abigel; Tilova, Elena; Girolami, Mark; Jones, Kate E.

    2018-01-01

    Passive acoustic sensing has emerged as a powerful tool for quantifying anthropogenic impacts on biodiversity, especially for echolocating bat species. To better assess bat population trends there is a critical need for accurate, reliable, and open source tools that allow the detection and classification of bat calls in large collections of audio recordings. The majority of existing tools are commercial or have focused on the species classification task, neglecting the important problem of first localizing echolocation calls in audio which is particularly problematic in noisy recordings. We developed a convolutional neural network based open-source pipeline for detecting ultrasonic, full-spectrum, search-phase calls produced by echolocating bats. Our deep learning algorithms were trained on full-spectrum ultrasonic audio collected along road-transects across Europe and labelled by citizen scientists from www.batdetective.org. When compared to other existing algorithms and commercial systems, we show significantly higher detection performance of search-phase echolocation calls with our test sets. As an example application, we ran our detection pipeline on bat monitoring data collected over five years from Jersey (UK), and compared results to a widely-used commercial system. Our detection pipeline can be used for the automatic detection and monitoring of bat populations, and further facilitates their use as indicator species on a large scale. Our proposed pipeline makes only a small number of bat specific design decisions, and with appropriate training data it could be applied to detecting other species in audio. A crucial novelty of our work is showing that with careful, non-trivial, design and implementation considerations, state-of-the-art deep learning methods can be used for accurate and efficient monitoring in audio. PMID:29518076

  5. Effects of microchannel confinement on acoustic vaporisation of ultrasound phase change contrast agents

    Science.gov (United States)

    Lin, Shengtao; Zhang, Ge; Hau Leow, Chee; Tang, Meng-Xing

    2017-09-01

    The sub-micron phase change contrast agent (PCCA) composed of a perfluorocarbon liquid core can be activated into gaseous state and form stable echogenic microbubbles for contrast-enhanced ultrasound imaging. It has shown great promise in imaging microvasculature, tumour microenvironment, and cancer cells. Although PCCAs have been extensively studied for different diagnostic and therapeutic applications, the effect of biologically geometrical confinement on the acoustic vaporisation of PCCAs is still not clear. We have investigated the difference in PCCA-produced ultrasound contrast enhancement after acoustic activation with and without a microvessel confinement on a microchannel phantom. The experimental results indicated more than one-order of magnitude less acoustic vaporisation in a microchannel than that in a free environment taking into account the attenuation effect of the vessel on the microbubble scattering. This may provide an improved understanding in the applications of PCCAs in vivo.

  6. Assisting the Visually Impaired: Obstacle Detection and Warning System by Acoustic Feedback

    Directory of Open Access Journals (Sweden)

    Andrés Cela

    2012-12-01

    Full Text Available The aim of this article is focused on the design of an obstacle detection system for assisting visually impaired people. A dense disparity map is computed from the images of a stereo camera carried by the user. By using the dense disparity map, potential obstacles can be detected in 3D in indoor and outdoor scenarios. A ground plane estimation algorithm based on RANSAC plus filtering techniques allows the robust detection of the ground in every frame. A polar grid representation is proposed to account for the potential obstacles in the scene. The design is completed with acoustic feedback to assist visually impaired users while approaching obstacles. Beep sounds with different frequencies and repetitions inform the user about the presence of obstacles. Audio bone conducting technology is employed to play these sounds without interrupting the visually impaired user from hearing other important sounds from its local environment. A user study participated by four visually impaired volunteers supports the proposed system.

  7. Is the gene encoding Chibby implicated as a tumour suppressor in colorectal cancer ?

    International Nuclear Information System (INIS)

    Gad, Sophie; Teboul, David; Lièvre, Astrid; Goasguen, Nicolas; Berger, Anne; Beaune, Philippe; Laurent-Puig, Pierre

    2004-01-01

    A novel member of the Wnt signalling pathway, Chibby, was recently identified. This protein inhibits Wnt/β-catenin mediated transcriptional activation by competing with Lef-1 (the transcription factor and target of β-catenin) to bind to β-catenin. This suggests that Chibby could be a tumour suppressor protein. The C22orf2 gene coding Chibby is located on chromosome 22, a region recurrently lost in colorectal cancer. Activation of the Wnt pathway is a major feature of colorectal cancer and occurs through inactivation of APC or activation of β-catenin. All of this led us to analyse the possible implication of Chibby in colorectal carcinogenesis. First, 36 tumour and matched normal colonic mucosa DNA were genotyped with five microsatellite markers located on chromosome 22 to search for loss of heterozygosity. Then, mutation screening of the C22orf2 coding sequence and splice sites was performed in the 36 tumour DNA. Finally, expression of Chibby was analysed by quantitative RT-PCR on 10 patients, 4 with loss of heterozygosity (LOH) on chromosome 22. Loss of heterozygosity involving the C22orf2 region was detected in 11 out of 36 patients (30%). Sequencing analysis revealed a known variant, rs3747174, in exon 5: T321C leading to a silent amino acid polymorphism A107A. Allelic frequencies were 0.69 and 0.31 for T and C variants respectively. No other mutation was detected. Among the 10 patients studied, expression analysis revealed that Chibby is overexpressed in 2 tumours and underexpressed in 1. No correlations were found with 22q LOH status. As no somatic mutation was detected in C22orf2 in 36 colorectal tumour DNA, our results do not support the implication of Chibby as a tumour suppressor in colorectal carcinogenesis. This was supported by the absence of underexpression of Chibby among the tumour samples with 22q LOH. The implication of other Wnt pathway members remains to be identified to explain the part of colorectal tumours without mutation in APC and β-catenin

  8. Clinical predictors of facial nerve outcome after translabyrinthine resection of acoustic neuromas.

    Science.gov (United States)

    Shamji, Mohammed F; Schramm, David R; Benoit, Brien G

    2007-01-01

    The translabyrinthine approach to acoustic neuroma resection offers excellent exposure for facial nerve dissection with 95% preservation of anatomic continuity. Acceptable outcome in facial asymptomatic patients is reported at 64-90%, but transient postoperative deterioration often occurs. The objective of this study was to identify preoperative clinical presentation and intraoperative surgical findings that predispose patients to facial nerve dysfunction after acoustic neuroma surgery. The charts of 128 consecutive translabyrinthine patients were examined retrospectively to identify new clinical and intraoperative predictors of facial nerve outcome. Postoperative evaluation of patients to normal function or mild asymmetry upon close inspection (House-Brackmann grades of I or II) was defined as an acceptable outcome, with obvious asymmetry to no movement (grades III to VI) defined as unacceptable. Intraoperative nerve stimulation was performed in all cases, and clinical grading was performed by a single neurosurgeon in all cases. Among patients with no preoperative facial nerve deficit, 87% had an acceptable result. Small size (P mA (P< 0.01) were reaffirmed as predictive of functional nerve preservation. Additionally, preoperative tinnitus (P = 0.03), short duration of hearing loss (P< 0. 01), and lack of subjective tumour adherence to the facial nerve (P = 0.02) were independently correlated with positive outcome. Our experience with the translabyrinthine approach reveals the previously unestablished associations of facial nerve outcome to include presence of tinnitus and duration of hypoacusis. Independent predictors of tumour size and nerve stimulation thresholds were reaffirmed, and the subjective description of tumour adherence to the facial nerve making dissection more difficult appears to be important.

  9. Tc(V)-DMS tumour imaging agent

    International Nuclear Information System (INIS)

    Horiuchi, K.; Yomoda, I.; Yokoyama, A.; Endo, K.; Torizuka, K.

    1986-01-01

    The data obtained by the authors provide good evidence of Tc(V)-DMS as a stable, large-molecular-size Tc-complex or polynuclear Tc-complex, comparable to Tc-cit and Ga-cit. A role for this polynuclear configuration in the generation of Tc-species with affinity for neoplastic cells was demonstrated using the dilution method as a promoter of Tc(V)-DMS dissociation. The concurrent Ehrlich ascites tumour cell uptake studies with TLC analysis revealed the chromatographically detected changes well traced by the biological cell utilization. The biological implications of dilution as one of the factors regulating radiopharmaceutical delivery to the tumour cell tissue were better demonstrated in the biodistribution studies carried out with Erhlich ascites-bearing mice. If, on the basis of the present data, the authors may take their postulate one step further, a more dissociated Tc-species, defined speculatively as TcO/sub 4//sup 3-/, might constitute an active Tc- species within the cell interacting with some tumour-specific substance or site. Research to find evidence of its presence is currently in progress

  10. Streptavidin Modified ZnO Film Bulk Acoustic Resonator for Detection of Tumor Marker Mucin 1

    Science.gov (United States)

    Zheng, Dan; Guo, Peng; Xiong, Juan; Wang, Shengfu

    2016-09-01

    A ZnO-based film bulk acoustic resonator has been fabricated using a magnetron sputtering technology, which was employed as a biosensor for detection of mucin 1. The resonant frequency of the thin-film bulk acoustic resonator was located near at 1503.3 MHz. The average electromechanical coupling factor {K}_{eff}^2 and quality factor Q were 2.39 % and 224, respectively. Using the specific binding system of avidin-biotin, the streptavidin was self-assembled on the top gold electrode as the sensitive layer to indirectly test the MUC1 molecules. The resonant frequency of the biosensor decreases in response to the mass loading in range of 20-500 nM. The sensor modified with the streptavidin exhibits a high sensitivity of 4642.6 Hz/nM and a good selectivity.

  11. Theoretical analysis of leaky surface acoustic waves of point-focused acoustic lens and some experiments

    International Nuclear Information System (INIS)

    Ishikawa, Isao; Suzuki, Yoshiaki; Ogura, Yukio; Katakura, Kageyoshi

    1997-01-01

    When a point-focused acoustic lens in the scanning acoustic microscope (SAM) is faced to test specimen and defocused to some extent, two effective echoes can be obtained. One is the echo of longitudinal wave, which is normally incident upon the specimen of an on-axis beam in the central region of the lens and is reflected normal to the lens surface, hence detected by the transducer. The other is of leaky surface acoustic waves(LSAW), which are mode converted front a narrow beam of off-axis longitudinal wave, then propagate across the surface of the specimen and reradiate at angles normal to the lens surface, thus detected by the transducer. These two echoes are either interfered or separated with each other depending ell the defocused distance. It turned out theoretically that the LSAW have a narrow focal spot in the central region of the point-focused acoustic lens, whose size is approximately 40% of the LSAW wavelength. On top of that, a wavelength of LSAW is about 50% short as that of longitudinal wave. So, It is expected that high resolution images can be obtained provided LSAW are used in the scanning acoustic microscope.

  12. Tumour nuclear oestrogen receptor beta 1 correlates inversely with parathyroid tumour weight.

    Science.gov (United States)

    Haglund, Felix; Rosin, Gustaf; Nilsson, Inga-Lena; Juhlin, C Christofer; Pernow, Ylva; Norenstedt, Sophie; Dinets, Andrii; Larsson, Catharina; Hartman, Johan; Höög, Anders

    2015-03-01

    Primary hyperparathyroidism (PHPT) is a common endocrinopathy, frequently caused by a parathyroid adenoma, rarely by a parathyroid carcinoma that lacks effective oncological treatment. As the majority of cases are present in postmenopausal women, oestrogen signalling has been implicated in the tumourigenesis. Oestrogen receptor beta 1 (ERB1) and ERB2 have been recently identified in parathyroid adenomas, the former inducing genes coupled to tumour apoptosis. We applied immunohistochemistry and slide digitalisation to quantify nuclear ERB1 and ERB2 in 172 parathyroid adenomas, atypical adenomas and carcinomas, and ten normal parathyroid glands. All the normal parathyroid glands expressed ERB1 and ERB2. The majority of tumours expressed ERB1 (70.6%) at varying intensities, and ERB2 (96.5%) at strong intensities. Parathyroid carcinomas expressed ERB1 in three out of six cases and ERB2 in five out of six cases. The intensity of tumour nuclear ERB1 staining significantly correlated inversely with tumour weight (P=0.011), and patients whose tumours were classified as ERB1-negative had significantly greater tumour weight as well as higher serum calcium (P=0.002) and parathyroid hormone levels (P=0.003). Additionally, tumour nuclear ERB1 was not expressed differentially with respect to sex or age of the patient. Levels of tumour nuclear ERB2 did not correlate with clinical characteristics. In conclusion, decreased ERB1 immunoreactivity is associated with increased tumour weight in parathyroid adenomas. Given the previously reported correlation with tumour-suppressive signalling, selective oestrogen receptor modulation (SERMs) may play a role in the treatment of parathyroid carcinomas. Future studies of SERMs and oestrogen treatment in PHPT should consider tumour weight as a potential factor in pharmacological responsiveness. © 2015 The authors.

  13. Rapid detection of hypoxia-inducible factor-1-active tumours: pretargeted imaging with a protein degrading in a mechanism similar to hypoxia-inducible factor-1{alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Masashi [Kyoto University, Radioisotopes Research Laboratory, Kyoto University Hospital, Faculty of Medicine, Kyoto (Japan); Kyoto University, Department of Patho-Functional Bioanalysis, Graduate School of Pharmaceutical Sciences, Kyoto (Japan); Kudo, Takashi; Konishi, Hiroaki; Miyano, Azusa; Ono, Masahiro; Saji, Hideo [Kyoto University, Department of Patho-Functional Bioanalysis, Graduate School of Pharmaceutical Sciences, Kyoto (Japan); Kuge, Yuji [Kyoto University, Department of Patho-Functional Bioanalysis, Graduate School of Pharmaceutical Sciences, Kyoto (Japan); Hokkaido University, Central Institute of Isotope Science, Sapporo (Japan); Mukai, Takahiro [Kyushu University, Department of Biomolecular Recognition Chemistry, Graduate School of Pharmaceutical Sciences, Fukuoka (Japan); Tanaka, Shotaro; Kizaka-Kondoh, Shinae; Hiraoka, Masahiro [Kyoto University, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto (Japan)

    2010-08-15

    Hypoxia-inducible factor-1 (HIF-1) plays an important role in malignant tumour progression. For the imaging of HIF-1-active tumours, we previously developed a protein, POS, which is effectively delivered to and selectively stabilized in HIF-1-active cells, and a radioiodinated biotin derivative, (3-{sup 123}I-iodobenzoyl)norbiotinamide ({sup 123}I-IBB), which can bind to the streptavidin moiety of POS. In this study, we aimed to investigate the feasibility of the pretargeting method using POS and {sup 123}I-IBB for rapid imaging of HIF-1-active tumours. Tumour-implanted mice were pretargeted with POS. After 24 h, {sup 125}I-IBB was administered and subsequently, the biodistribution of radioactivity was investigated at several time points. In vivo planar imaging, comparison between {sup 125}I-IBB accumulation and HIF-1 transcriptional activity, and autoradiography were performed at 6 h after the administration of {sup 125}I-IBB. The same sections that were used in autoradiographic analysis were subjected to HIF-1{alpha} immunohistochemistry. {sup 125}I-IBB accumulation was observed in tumours of mice pretargeted with POS (1.6%ID/g at 6 h). This result is comparable to the data derived from {sup 125}I-IBB-conjugated POS-treated mice (1.4%ID/g at 24 h). In vivo planar imaging provided clear tumour images. The tumoral accumulation of {sup 125}I-IBB significantly correlated with HIF-1-dependent luciferase bioluminescence (R=0.84, p<0.01). The intratumoral distribution of {sup 125}I-IBB was heterogeneous and was significantly correlated with HIF-1{alpha}-positive regions (R=0.58, p<0.0001). POS pretargeting with {sup 123}I-IBB is a useful technique in the rapid imaging and detection of HIF-1-active regions in tumours. (orig.)

  14. A new framework for analysing automated acoustic species-detection data: occupancy estimation and optimization of recordings post-processing

    Science.gov (United States)

    Chambert, Thierry A.; Waddle, J. Hardin; Miller, David A.W.; Walls, Susan; Nichols, James D.

    2018-01-01

    The development and use of automated species-detection technologies, such as acoustic recorders, for monitoring wildlife are rapidly expanding. Automated classification algorithms provide a cost- and time-effective means to process information-rich data, but often at the cost of additional detection errors. Appropriate methods are necessary to analyse such data while dealing with the different types of detection errors.We developed a hierarchical modelling framework for estimating species occupancy from automated species-detection data. We explore design and optimization of data post-processing procedures to account for detection errors and generate accurate estimates. Our proposed method accounts for both imperfect detection and false positive errors and utilizes information about both occurrence and abundance of detections to improve estimation.Using simulations, we show that our method provides much more accurate estimates than models ignoring the abundance of detections. The same findings are reached when we apply the methods to two real datasets on North American frogs surveyed with acoustic recorders.When false positives occur, estimator accuracy can be improved when a subset of detections produced by the classification algorithm is post-validated by a human observer. We use simulations to investigate the relationship between accuracy and effort spent on post-validation, and found that very accurate occupancy estimates can be obtained with as little as 1% of data being validated.Automated monitoring of wildlife provides opportunity and challenges. Our methods for analysing automated species-detection data help to meet key challenges unique to these data and will prove useful for many wildlife monitoring programs.

  15. International Case-Control Study of Adult Brain, Head and Neck Tumours: Results of the Feasibility Study (invited paper)

    International Nuclear Information System (INIS)

    Cardis, E.; Kilkenny, M.

    1999-01-01

    The objectives of the feasibility study were to collect and analyse the information necessary to assess the feasibility of a multi-centric study of adult head and neck tumours (including brain tumours) and mobile telephones. Information was obtained on the availability and accessibility of records from companies, the prevalence of mobile telephone use over time and the expected number of tumour cases in the proposed study regions. The conclusion is that it is feasible to develop a study of the relation between mobile telephone use and brain cancer risk. The feasibility of a study of the relation between radiofrequency exposure and cancer risk is, however, unclear at present. It is unknown whether a sufficiently accurate and precise RF exposure gradient can be derived to classify adequately each subject in the proposed study. A study of the relation between mobile telephone use and risk of salivary gland tumours and acoustic neurinomas is probably feasible, but more information is required about the logistic difficulties of ascertaining these cases in the study regions. Two subcommittees have been formed to develop the exposure measurement and epidemiological aspect of the study. (author)

  16. Cancer-derived extracellular vesicles: friend and foe of tumour immunosurveillance.

    Science.gov (United States)

    Dörsam, Bastian; Reiners, Kathrin S; von Strandmann, Elke Pogge

    2018-01-05

    Extracellular vesicles (EVs) are important players of intercellular signalling mechanisms, including communication with and among immune cells. EVs can affect the surrounding tissue as well as peripheral cells. Recently, EVs have been identified to be involved in the aetiology of several diseases, including cancer. Tumour cell-released EVs or exosomes have been shown to promote a tumour-supporting environment in non-malignant tissue and, thus, benefit metastasis. The underlying mechanisms are numerous: loss of antigen expression, direct suppression of immune effector cells, exchange of nucleic acids, alteration of the recipient cells' transcription and direct suppression of immune cells. Consequently, tumour cells can subvert the host's immune detection as well as suppress the immune system. On the contrary, recent studies reported the existence of EVs able to activate immune cells, thus promoting the tumour-directed immune response. In this article, the immunosuppressive capabilities of EVs, on the one hand, and their potential use in immunoactivation and therapeutic potential, on the other hand, are discussed.This article is part of the discussion meeting issue 'Extracellular vesicles and the tumour microenvironment'. © 2017 The Authors.

  17. Spermatogenesis and testicular tumours in ageing dogs

    NARCIS (Netherlands)

    Peters, M. A.; de rooij, D. G.; Teerds, K. J.; van de Gaag, I.; van Sluijs, F. J.

    2001-01-01

    The aims of this investigation were to quantify the changes in canine spermatogenesis that occur during ageing and to study the prevalence of testicular tumours and their effects on spermatogenesis in dogs. Testes from 74 dogs of various breeds without clinically detected testicular disease and from

  18. Early detection of melanoma with the combined use of acoustic microscopy, infrared reflectance and Raman spectroscopy

    Science.gov (United States)

    Karagiannis, Georgios T.; Grivas, Ioannis; Tsingotjidou, Anastasia; Apostolidis, Georgios K.; Grigoriadou, Ifigeneia; Dori, I.; Poulatsidou, Kyriaki-Nefeli; Doumas, Argyrios; Wesarg, Stefan; Georgoulias, Panagiotis

    2015-03-01

    Malignant melanoma is a form of skin cancer, with increasing incidence worldwide. Early diagnosis is crucial for the prognosis and treatment of the disease. The objective of this study is to develop a novel animal model of melanoma and apply a combination of the non-invasive imaging techniques acoustic microscopy, infrared (IR) and Raman spectroscopies, for the detection of developing tumors. Acoustic microscopy provides information about the 3D structure of the tumor, whereas, both spectroscopic modalities give qualitative insight of biochemical changes during melanoma development. In order to efficiently set up the final devices, propagation of ultrasonic and electromagnetic waves in normal skin and melanoma simulated structures was performed. Synthetic and grape-extracted melanin (simulated tumors), endermally injected, were scanned and compared to normal skin. For both cases acoustic microscopy with central operating frequencies of 110MHz and 175MHz were used, resulting to the tomographic imaging of the simulated tumor, while with the spectroscopic modalities IR and Raman differences among spectra of normal and melanin- injected sites were identified in skin depth. Subsequently, growth of actual tumors in an animal melanoma model, with the use of human malignant melanoma cells was achieved. Acoustic microscopy and IR and Raman spectroscopies were also applied. The development of tumors at different time points was displayed using acoustic microscopy. Moreover, the changes of the IR and Raman spectra were studied between the melanoma tumors and adjacent healthy skin. The most significant changes between healthy skin and the melanoma area were observed in the range of 900-1800cm-1 and 350-2000cm-1, respectively.

  19. Proposed frustrated-total-reflection acoustic sensing method

    International Nuclear Information System (INIS)

    Hull, J.R.

    1981-01-01

    Modulation of electromagnetic energy transmission through a frustrated-total-reflection device by pressure-induced changes in the index of refraction is proposed for use as an acoustic detector. Maximum sensitivity occurs for angles of incidence near the critical angle. The minimum detectable pressure in air is limited by Brownian noise. Acoustic propagation losses and diffraction of the optical beam by the acoustic signal limit the minimum acoustic wavelength to lengths of the order of the spatial extent of the optical beam. The response time of the method is fast enough to follow individual acoustic waves

  20. Bilinear Time-frequency Analysis for Lamb Wave Signal Detected by Electromagnetic Acoustic Transducer

    Science.gov (United States)

    Sun, Wenxiu; Liu, Guoqiang; Xia, Hui; Xia, Zhengwu

    2018-03-01

    Accurate acquisition of the detection signal travel time plays a very important role in cross-hole tomography. The experimental platform of aluminum plate under the perpendicular magnetic field is established and the bilinear time-frequency analysis methods, Wigner-Ville Distribution (WVD) and the pseudo-Wigner-Ville distribution (PWVD), are applied to analyse the Lamb wave signals detected by electromagnetic acoustic transducer (EMAT). By extracting the same frequency component of the time-frequency spectrum as the excitation frequency, the travel time information can be obtained. In comparison with traditional linear time-frequency analysis method such as short-time Fourier transform (STFT), the bilinear time-frequency analysis method PWVD is more appropriate in extracting travel time and recognizing patterns of Lamb wave.

  1. Real-time system for studies of the effects of acoustic feedback on animal vocalizations.

    Directory of Open Access Journals (Sweden)

    Mike eSkocik

    2013-01-01

    Full Text Available Studies of behavioral and neural responses to distorted auditory feedback can help shed light on the neural mechanisms of animal vocalizations. We describe an apparatus for generating real-time acoustic feedback. The system can very rapidly detect acoustic features in a song and output acoustic signals if the detected features match the desired acoustic template. The system uses spectrogram-based detection of acoustic elements. It is low-cost and can be programmed for a variety of behavioral experiments requiring acoustic feedback or neural stimulation. We use the system to study the effects of acoustic feedback on birds' vocalizations and demonstrate that such an acoustic feedback can cause both immediate and long-term changes to birds’ songs.

  2. Assessment of the residual tumour of colorectal liver metastases after chemotherapy: diffusion-weighted MR magnetic resonance imaging in the peripheral and entire tumour

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Mathilde; Doblas, Sabrina; Giraudeau, Celine [Paris Diderot University, INSERM, UMR 1149, Clichy (France); Ronot, Maxime; Van Beers, Bernard; Vilgrain, Valerie [Paris Diderot University, INSERM, UMR 1149, Clichy (France); Radiology Department, Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hopitaux de Paris, APHP, Clichy (France); Belghiti, Jacques [Hepatobiliary Surgery Department, Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hopitaux de Paris, APHP, Clichy (France); Paradis, Valerie [Pathology Department, Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Assistance Publique-Hopitaux de Paris, APHP, Clichy (France)

    2016-01-15

    To evaluate the value of diffusion-weighted imaging (DWI) in detecting residual tumours (RTs) in colorectal liver metastases (CLMs) following chemotherapy, with a focus on tumour periphery. From January 2009-January 2012, 57 patients who underwent liver resection for CLMs with preoperative MRI (<3 months) including DWI were retrospectively included. CLMs were classified into three response groups on pathology: (1) major histological (MHR, RTs ≤ 10 %), (2) partial histological (PHR, RT = 10-49 %), and (3) no histological (NHR, RT ≥ 50 %). On DWI, regions of interest (ROIs) were drawn around the entire tumour and tumour periphery. Apparent diffusion (ADC) and pure diffusion (D) coefficients were calculated using a monoexponential fit, and compared using Kruskal-Wallis test on a lesion-per-lesion analysis. 111 CLMs were included. Fourteen (12.5 %), 42 (38 %) and 55 (49.5 %) CLMs presented a MHR, PHR and NHR, respectively. ADC and D of the peripheral ROIs were significantly higher in the MHR group (P = 0.013/P = 0.013). ADC and D from the entire tumour were not significantly different among the groups (P = 0.220/P = 0.103). In CLM treated with chemotherapy, ADC and D values from the entire tumour are not related to the degree of RT, while peripheral zone diffusion parameters could help identify metastases with MHR. (orig.)

  3. Acoustic parametric pumping of spin waves

    Science.gov (United States)

    Keshtgar, Hedyeh; Zareyan, Malek; Bauer, Gerrit E. W.

    2014-11-01

    Recent experiments demonstrated generation of spin currents by ultrasound. We can understand this acoustically induced spin pumping in terms of the coupling between magnetization and lattice waves. Here we study the parametric excitation of magnetization by longitudinal acoustic waves and calculate the acoustic threshold power. The induced magnetization dynamics can be detected by the spin pumping into an adjacent normal metal that displays the inverse spin Hall effect.

  4. Acoustic parametric pumping of spin waves

    OpenAIRE

    Keshtgar, Hedyeh; Zareyan, Malek; Bauer, Gerrit E. W.

    2013-01-01

    Recent experiments demonstrated generation of spin currents by ultrasound. We can understand this acoustically induced spin pumping in terms of the coupling between magnetization and lattice waves. Here we study the parametric excitation of magnetization by longitudinal acoustic waves and calculate the acoustic threshold power. The induced magnetization dynamics can be detected by the spin pumping into an adjacent normal metal that displays the inverse spin Hall effect.

  5. Imaging of sacral tumours

    International Nuclear Information System (INIS)

    Gerber, S.; Ollivier, L.; Brisse, H.; Neuenschwander, S.; Leclere, J.; Vanel, D.; Missenard, G.; Pinieux, G. de

    2008-01-01

    All components of the sacrum (bone, cartilage, bone marrow, meninges, nerves, notochord remnants, etc.) can give rise to benign or malignant tumours. Bone metastases and intraosseous sites of haematological malignancies, lymphoma and multiple myeloma are the most frequent aetiologies, while primary bone tumours and meningeal or nerve tumours are less common. Some histological types have a predilection for the sacrum, especially chordoma and giant cell tumour. Clinical signs are usually minor, and sacral tumours are often discovered in the context of nerve root or pelvic organ compression. The roles of conventional radiology, CT and MRI are described and compared with the histological features of the main tumours. The impact of imaging on treatment decisions and follow-up is also reviewed. (orig.)

  6. Imaging of sacral tumours

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, S.; Ollivier, L.; Brisse, H.; Neuenschwander, S. [Institut Curie, Department of Radiology, Paris (France); Leclere, J. [Institut Gustave Roussy, Department of Radiology, Villejuif (France); Vanel, D. [The Rizzoli Institute, Department of Radiology, Bologna (Italy); Missenard, G. [Institut Gustave Roussy, Comite de pathologie tumorale de l' appareil locomoteur, Villejuif (France); Pinieux, G. de [CHRU de Tours, Department of Pathology, Hopital Trousseau, Tours (France)

    2008-04-15

    All components of the sacrum (bone, cartilage, bone marrow, meninges, nerves, notochord remnants, etc.) can give rise to benign or malignant tumours. Bone metastases and intraosseous sites of haematological malignancies, lymphoma and multiple myeloma are the most frequent aetiologies, while primary bone tumours and meningeal or nerve tumours are less common. Some histological types have a predilection for the sacrum, especially chordoma and giant cell tumour. Clinical signs are usually minor, and sacral tumours are often discovered in the context of nerve root or pelvic organ compression. The roles of conventional radiology, CT and MRI are described and compared with the histological features of the main tumours. The impact of imaging on treatment decisions and follow-up is also reviewed. (orig.)

  7. NEMO-SMO acoustic array: A deep-sea test of a novel acoustic positioning system for a km3-scale underwater neutrino telescope

    Science.gov (United States)

    Viola, S.; Ardid, M.; Bertin, V.; Enzenhöfer, A.; Keller, P.; Lahmann, R.; Larosa, G.; Llorens, C. D.; NEMO Collaboration; SMO Collaboration

    2013-10-01

    Within the activities of the NEMO project, the installation of a 8-floors tower (NEMO-Phase II) at a depth of 3500 m is foreseen in 2012. The tower will be installed about 80 km off-shore Capo Passero, in Sicily. On board the NEMO tower, an array of 18 acoustic sensors will be installed, permitting acoustic detection of biological sources, studies for acoustic neutrino detection and primarily acoustic positioning of the underwater structures. For the latter purpose, the sensors register acoustic signals emitted by five acoustic beacons anchored on the sea-floor. The data acquisition system of the acoustic sensors is fully integrated with the detector data transport system and is based on an “all data to shore” philosophy. Signals coming from hydrophones are continuously sampled underwater at 192 kHz/24 bit and transmitted to shore through an electro-optical cable for real-time analysis. A novel technology for underwater GPS time-stamping of data has been implemented and tested. The operation of the acoustic array will permit long-term test of sensors and electronics technologies that are proposed for the acoustic positioning system of KM3NeT.

  8. Damage detection in wind turbine blades using acoustic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Juengert, A., E-mail: anne.juengert@mpa.uni-stuttgart.de [Univ. of Stuttgart, Materialpruefungsanstalt Stuttgart, Stuttgart (Germany)

    2013-05-15

    Facing climate change, the use of renewable energy gains importance. The wind energy sector grows very fast. Bigger and more powerful wind turbines will be built in the coming decades and the safety and reliability of the turbines will become more important. Wind turbine blades have to be inspected at regular intervals, because they are highly stressed during operation and a blade breakdown can cause big economic damages. The turbine blades consist of fiber reinforced plastics (GFRP/CFRP) and sandwich areas containing wood or plastic foam. The blades are manufactured as two halves and glued together afterwards. Typical damages are delaminations within the GFRP or the sandwich and missing adhesive or deficient bond at the bonding surfaces. The regular inspections of wind turbine blades are performed manually by experts and are limited to visual appraisals and simple tapping tests. To improve the inspections of wind turbine blades non-destructive testing techniques using acoustic waves are being developed. To detect delaminations within the laminates of the turbine blade, a local resonance spectroscopy was used. To detect missing bond areas from the outside of the blade the impulse-echo-technique was applied. This paper is an updated reprint of an article published on ndt.net in 2008. (author)

  9. Damage detection in wind turbine blades using acoustic techniques

    International Nuclear Information System (INIS)

    Juengert, A.

    2013-01-01

    Facing climate change, the use of renewable energy gains importance. The wind energy sector grows very fast. Bigger and more powerful wind turbines will be built in the coming decades and the safety and reliability of the turbines will become more important. Wind turbine blades have to be inspected at regular intervals, because they are highly stressed during operation and a blade breakdown can cause big economic damages. The turbine blades consist of fiber reinforced plastics (GFRP/CFRP) and sandwich areas containing wood or plastic foam. The blades are manufactured as two halves and glued together afterwards. Typical damages are delaminations within the GFRP or the sandwich and missing adhesive or deficient bond at the bonding surfaces. The regular inspections of wind turbine blades are performed manually by experts and are limited to visual appraisals and simple tapping tests. To improve the inspections of wind turbine blades non-destructive testing techniques using acoustic waves are being developed. To detect delaminations within the laminates of the turbine blade, a local resonance spectroscopy was used. To detect missing bond areas from the outside of the blade the impulse-echo-technique was applied. This paper is an updated reprint of an article published on ndt.net in 2008. (author)

  10. Positron emission tomography (PET) and pancreatic tumours; Tomographie par emission de positons (TEP) et tumeurs pancreatiques

    Energy Technology Data Exchange (ETDEWEB)

    Montravers, F.; Kerrou, K.; Grahek, D.; Gutman, F.; Beco, V. de; Talbot, J.N. [Hopital Tenon, Service de Medecine, 75 - Paris (France)

    2005-07-15

    Neoplasms of the pancreas may originate front both exocrine and endocrine cells but in 90% of the cases, they correspond to ductal adenocarcinomas. For adenocarcinomas, the major indication of FDG-PET corresponds to the pre-operative staging because unexpected distant metastases can be detected by FDG-PET in about 20 to 40% of the cases, which results in avoidance of unnecessary surgical procedures. FDG PET is also useful in evaluation of the treatment effect, monitoring after the operation and detection of recurrent pancreatic cancers. For the characterisation of the pancreatic tumour, the performance of FDG-PET is sometimes limited due to poor cellularity, hyperglycemia or inflammatory processes. especially for large tumours and is indicated only in cases of doubtful results of CT or MRI. For endocrine pancreatic tumours, FDG-PET is useful only in case of poorly-differentiated and aggressive tumours. F-DOPA PET can he useful, complementary to pentetreotide scintigraphy, in well-differentiated endocrine tumours. (authors)

  11. Dual fiber Bragg gratings configuration-based fiber acoustic sensor for low-frequency signal detection

    Science.gov (United States)

    Yang, Dong; Wang, Shun; Lu, Ping; Liu, Deming

    2014-11-01

    We propose and fabricate a new type fiber acoustic sensor based on dual fiber Bragg gratings (FBGs) configuration. The acoustic sensor head is constructed by putting the sensing cells enclosed in an aluminum cylinder space built by two Cband FBGs and a titanium diaphragm of 50 um thickness. One end of each FBG is longitudinally adhered to the diaphragm by UV glue. Both of the two FBGs are employed for reflecting light. The dual FBGs play roles not only as signal transmission system but also as sensing component, and they demodulate each other's optical signal mutually during the measurement. Both of the two FBGs are pre-strained and the output optical power experiences fluctuation in a linear relationship along with a variation of axial strain and surrounding acoustic interference. So a precise approach to measure the frequency and sound pressure of the acoustic disturbance is achieved. Experiments are performed and results show that a relatively flat frequency response in a range from 200 Hz to 1 kHz with the average signal-to-noise ratio (SNR) above 21 dB is obtained. The maximum sound pressure sensitivity of 11.35mV/Pa is achieved with the Rsquared value of 0.99131 when the sound pressure in the range of 87.7-106.6dB. It has potential applications in low frequency signal detection. Owing to its direct self-demodulation method, the sensing system reveals the advantages of easy to demodulate, good temperature stability and measurement reliability. Besides, performance of the proposed sensor could be improved by optimizing the parameters of the sensor, especially the diaphragm.

  12. Genomic instability: potential contributions to tumour and normal tissue response, and second tumours, after radiotherapy

    International Nuclear Information System (INIS)

    Hendry, Jolyon H.

    2001-01-01

    Purpose: Induced genomic instability generally refers to a type of damage which is transmissible down cell generations, and which results in a persistently enhanced frequency of de novo mutations, chromosomal abnormalities or lethality in a significant fraction of the descendant cell population. The potential contribution of induced genomic instability to tumour and normal tissue response, and second tumours, after radiotherapy, is explored. Results: The phenomenon of spontaneous genomic instability is well known in some rare genetic diseases (e.g. Gorlin's syndrome), and there is evidence in such cases that it can lead to a greater propensity for carcinogenesis (with shortened latency) which is enhanced after irradiation. It is unclear what role induced genomic instability plays in the response of normal individuals, but persistent chromosomal instability has been detected in vivo in lymphocytes and keratinocytes from irradiated normal individuals. Such induced genomic instability might play some role in tumour response in a subset of tumours with specific defects in damage response genes, but again its contribution to radiocurability in the majority of cancer patients is unclear. In normal tissues, genomic instability induced in wild-type cells leading to delayed cell death might contribute to more severe or prolonged early reactions as a consequence of increased cell loss, a longer time required for recovery, and greater residual injury. In tumours, induced genomic instability reflected in delayed reductions in clonogenic capacity might contribute to the radiosensitivity of primary tumours, and also to a lower incidence, longer latency and slower growth rate of recurrences and metastases. Conclusions: The evidence which is reviewed shows that there is little information at present to support these propositions, but what exists is consistent with their expectations. Also, it is not yet clear to what extent mutations associated with genomic instability

  13. Acoustic detection, tracking, and characterization of three tornadoes.

    Science.gov (United States)

    Frazier, William Garth; Talmadge, Carrick; Park, Joseph; Waxler, Roger; Assink, Jelle

    2014-04-01

    Acoustic data recorded at 1000 samples per second by two sensor arrays located at ranges of 1-113 km from three tornadoes that occurred on 24 May 2011 in Oklahoma are analyzed. Accurate bearings to the tornadoes have been obtained using beamforming methods applied to the data at infrasonic frequencies. Beamforming was not viable at audio frequencies, but the data demonstrate the ability to detect significant changes in the shape of the estimated power spectral density in the band encompassing 10 Hz to approximately 100 Hz at distances of practical value from the sensors. This suggests that arrays of more closely spaced sensors might provide better bearing accuracy at practically useful distances from a tornado. Additionally, a mathematical model, based on established relationships of aeroacoustic turbulence, is demonstrated to provide good agreement to the estimated power spectra produced by the tornadoes at different times and distances from the sensors. The results of this analysis indicate that, qualitatively, an inverse relationship appears to exist between the frequency of an observed peak of the power spectral density and the reported tornado intensity.

  14. Screening for Circulating Tumour Cells Allows Early Detection of Cancer and Monitoring of Treatment Effectiveness: An Observational Study

    Science.gov (United States)

    Ried, Karin; Eng, Peter; Sali, Avni

    2017-08-27

    Background: Circulating-Tumour-Cells (CTC) provide a blood biomarker for early carcinogenesis, cancer progression and treatment effectiveness. An increase in CTCs is associated with cancer progression, a CTC decrease with cancer containment or remission. Several technologies have been developed to identify CTC, including the validated Isolation-by-Size-of-Epithelial-Tumour (ISET, Rarecells) technology, combining blood filtration and microscopy using standard histo-pathological criteria. Methods: This observational study compared CTC count to cancer status and cancer risk, by monitoring treatment effectiveness in cancer patients and by screening for CTC in asymptomatic patients with risk factors, including family history of cancer. Results: Between Sept-2014 and Dec-2016 we undertook 600 CTC tests (542 patients), including 50% screening requests of patients without cancer diagnosis but with risk factors. CTC were detected in all cancer patients (n=277, 100%), and in half of the asymptomatic patients screened (50%, 132 out-of 265 patients). Follow-up tests including scans, scheduled within 1-10 months of positive CTC tests, found early cancerous lesions in 20% of screened patients. In 50% of male patients with CTC and normal PSA (prostate-specific-antigen) levels, PSMA-PET scans revealed increased uptake in the prostate, indicative of early prostate cancer. Other types of cancers detected by CTC screening and subsequent scans included early breast, ovarian, lung, or renal cancer. Patients with CTC were advised on integrative approaches including immune-stimulating and anti-carcinogenic nutritional therapies. CTC repeat tests were available in 10% of patients with detected CTC (40 outof 409 patients, n=98 CTC tests) to assess treatment effectiveness, suggesting nutritional therapies to be beneficial in reducing CTC count. Conclusions: CTC screening provided a highly sensitive biomarker for the early detection of cancer, with higher CTC counts being associated with

  15. Image-based computational quantification and visualization of genetic alterations and tumour heterogeneity.

    Science.gov (United States)

    Zhong, Qing; Rüschoff, Jan H; Guo, Tiannan; Gabrani, Maria; Schüffler, Peter J; Rechsteiner, Markus; Liu, Yansheng; Fuchs, Thomas J; Rupp, Niels J; Fankhauser, Christian; Buhmann, Joachim M; Perner, Sven; Poyet, Cédric; Blattner, Miriam; Soldini, Davide; Moch, Holger; Rubin, Mark A; Noske, Aurelia; Rüschoff, Josef; Haffner, Michael C; Jochum, Wolfram; Wild, Peter J

    2016-04-07

    Recent large-scale genome analyses of human tissue samples have uncovered a high degree of genetic alterations and tumour heterogeneity in most tumour entities, independent of morphological phenotypes and histopathological characteristics. Assessment of genetic copy-number variation (CNV) and tumour heterogeneity by fluorescence in situ hybridization (ISH) provides additional tissue morphology at single-cell resolution, but it is labour intensive with limited throughput and high inter-observer variability. We present an integrative method combining bright-field dual-colour chromogenic and silver ISH assays with an image-based computational workflow (ISHProfiler), for accurate detection of molecular signals, high-throughput evaluation of CNV, expressive visualization of multi-level heterogeneity (cellular, inter- and intra-tumour heterogeneity), and objective quantification of heterogeneous genetic deletions (PTEN) and amplifications (19q12, HER2) in diverse human tumours (prostate, endometrial, ovarian and gastric), using various tissue sizes and different scanners, with unprecedented throughput and reproducibility.

  16. Malignant renal tumours in adults in Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria.

    Science.gov (United States)

    Mbaeri, T U; Orakwe, J C; Nwofor, A M E; Oranusi, C K; Ulebe, A O

    2012-01-01

    Malignant renal tumour is the third commonest urological tumour after prostate and bladder cancer. It is however the urological tumour with the highest mortality/incidence ratio. To review the frequency, mode of presentation and histological pattern of patients with malignant renal tumours in Nnamdi Azikiwe University Teaching Hospital. A 7 year retrospective review of all our renal tumour folders in the institution. 19 patients qualified for the study with a male/female ratio of 1:2.8 and a mean age of 52.6 +/- 15.8 years. The peak age was in the seventh decade. Most patient present late (78.9%).Renal cell cancer was the commonest tumour type with the commonest mode of presentation being abdominal mass and pain. Malignant renal tumours present very late in our environment and patients hesitate in accepting available treatment option which is surgery. There is need for increased patient awareness and high index of suspicion by the clinician, particularly during imaging procedures, as this would significantly enhance the early detection of these patients.

  17. [F18]-FDG imaging of experimental animal tumours using a hybrid gamma-camera

    International Nuclear Information System (INIS)

    Lausson, S.; Maurel, G.; Kerrou, K.; Montravers, F.; Petegnief, Y.; Talbot, J.N.; Fredelizi, D.

    2001-01-01

    Positron emission tomography (PET) has been widely used in clinical studies. This technology permits detection of compounds labelled with positron emitting radionuclides and in particular, [F18]-fluorodeoxyglucose ([F18]-FDG).[F18]-FDG uptake and accumulation is generally related to malignancy; some recent works have suggested the usefulness of PET camera dedicated to small laboratory animals (micro-PET). Our study dealt with the feasibility of [F18]-FDG imaging of malignant tumours in animal models by means of an hybrid camera dedicated for human scintigraphy. We evaluated the ability of coincidence detection emission tomography (CDET) using this hybrid camera to visualize in vivo subcutaneous tumours grafted to mice or rats. P815 murine mastocytoma grafted in syngeneic DBA/2 mice resulted with foci of very high FDG uptake. Tumours with a diameter of only 3 mm were clearly visualized. Medullary thyroid cancer provoked by rMTC 6/23 and CA77 lines in syngeneic Wag/Rij rat was also detected. The differentiated CA77 tumours exhibited avidity for [F18]-FDG and a tumour, which was just palpable (diameter lower than 2 mm), was identified. In conclusion, CDET-FDG is a non-invasive imaging tool which can be used to follow grafted tumours in the small laboratory animal, even when their size is smaller than 1 cm. It has the potential to evaluate experimental anticancer treatments in small series of animals by individual follow-up. It offers the opportunity to develop experimental PET research within a nuclear medicine or biophysics department, the shift to a dedicated micro-PET device being subsequently necessary. It is indeed compulsory to strictly follow the rules for non contamination and disinfection of the hybrid camera. (authors)

  18. Application of gas-coupled laser acoustic detection to gelatins and underwater sensing

    International Nuclear Information System (INIS)

    Caron, James N.; Kunapareddy, Pratima

    2014-01-01

    Gas-coupled Laser Acoustic Detection (GCLAD) has been used as a method to sense ultrasound waves in materials without contact of the material surface. To sense the waveform, a laser beam is directed parallel to the material surface and displaced or deflected when the radiated waveform traverses the beam. We present recent tests that demonstrate the potential of using this technique for detecting ultrasound in gelatin phantoms and in water. As opposed to interferometric detection, GCLAD operates independently of the optical surface properties of the material. This allows the technique to be used in cases where the material is transparent or semi-transparent. We present results on sensing ultrasound in gelatin phantoms that are used to mimic biological materials. As with air-coupled transducers, the frequency response of GCLAD at high frequencies is limited by the high attenuation of ultrasound in air. In contrast, water has a much lower attenuation. Here we demonstrate the use of a GCLAD-like system in water, measuring the directivity response at 1 MHz and sensing waveforms with higher frequency content

  19. Leak detection evaluation of boiler tube for power plant using acoustic emission

    International Nuclear Information System (INIS)

    Lee, Sang Guk; Chung, Min Hwa; Nam, Ki Woo

    2001-01-01

    Main equipment of thermal power plant, such as boiler and turbine, are designed and manufactured by domestic techniques. And also the automatic control facilities controlling the main equipment are at the applying step of the localization. and many parts of BOP(Balance Of Plant) equipment are utilizing, localized. But because the special equipment monitoring the operation status of the main facilities such as boiler and turbine are still dependent upon foreign technology and especially boiler tube leak detection system is under the initial step of first application to newly-constructed plants and the manufacturing and application are done by foreign techniques mostly, fast localization development is required. Therefore, so as to study and develop boiler tube leak detection system, we performed studying on manufacturing, installation in site, acoustic emission(AE) signal analysis and discrimination etc. As a result of studying on boiler tube leak detection using AE, we conformed that diagnosis for boiler tube and computerized their trend management is possible, and also it is expected to contribute to safe operation of power generation facilities.

  20. Alpha-amidated peptides derived from pro-opiomelanocortin in human pituitary tumours

    DEFF Research Database (Denmark)

    Fenger, M; Johnsen, A H

    1988-01-01

    Human pituitary tumours, obtained at surgery for Cushing's disease and Nelson's syndrome, were extracted and the content and molecular forms of pro-opiomelanocortin (POMC)-derived peptides determined by radioimmunoassay, gel chromatography, reversed-phase high-performance liquid chromatography....... In conclusion, all the molecular forms of the amidated peptides detected in tumours from patients with Cushing's disease and Nelson's syndrome were similar to the molecular forms found in the normal human pituitary. The main difference between the tumours and the normal pituitary was the greater amount...... (HPLC) and sequence analysis. In the tumours from patients with Cushing's disease the mean concentrations of amidated peptides relative to the total amount of POMC were as follows: alpha-MSH, 1.7%; amidated gamma-MSH (gamma 1-MSH), 8.5% and the peptide linking gamma-MSH and ACTH in the precursor (hinge...

  1. Mismatch negativity to acoustical illusion of beat: how and where the change detection takes place?

    Science.gov (United States)

    Chakalov, Ivan; Paraskevopoulos, Evangelos; Wollbrink, Andreas; Pantev, Christo

    2014-10-15

    In case of binaural presentation of two tones with slightly different frequencies the structures of brainstem can no longer follow the interaural time differences (ITD) resulting in an illusionary perception of beat corresponding to frequency difference between the two prime tones. Hence, the beat-frequency does not exist in the prime tones presented to either ear. This study used binaural beats to explore the nature of acoustic deviance detection in humans by means of magnetoencephalography (MEG). Recent research suggests that the auditory change detection is a multistage process. To test this, we employed 26 Hz-binaural beats in a classical oddball paradigm. However, the prime tones (250 Hz and 276 Hz) were switched between the ears in the case of the deviant-beat. Consequently, when the deviant is presented, the cochleae and auditory nerves receive a "new afferent", although the standards and the deviants are heard identical (26 Hz-beats). This allowed us to explore the contribution of auditory periphery to change detection process, and furthermore, to evaluate its influence on beats-related auditory steady-state responses (ASSRs). LORETA-source current density estimates of the evoked fields in a typical mismatch negativity time-window (MMN) and the subsequent difference-ASSRs were determined and compared. The results revealed an MMN generated by a complex neural network including the right parietal lobe and the left middle frontal gyrus. Furthermore, difference-ASSR was generated in the paracentral gyrus. Additionally, psychophysical measures showed no perceptual difference between the standard- and deviant-beats when isolated by noise. These results suggest that the auditory periphery has an important contribution to novelty detection already at sub-cortical level. Overall, the present findings support the notion of hierarchically organized acoustic novelty detection system. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. The influence of somatostatin receptor scintigraphy during preoperative staging of non-functioning pancreatic neuroendocrine tumours

    International Nuclear Information System (INIS)

    Jilesen, A.P.J.; Hoefnagel, S.J.M.; Busch, O.R.C.; Bennink, R.J.; Gouma, D.J.; Nieveen van Dijkum, E.J.M.

    2016-01-01

    Aim: To determine whether somatostatin receptor scintigraphy (SRS) influences the preoperative staging and clinical management of non-functioning pancreatic neuroendocrine tumours (NF-pNETs). Materials and methods: All SRS examinations performed between 2002–2013 were selected. Patients with NF-pNET were included if both computed tomography (CT) and SRS was performed during preoperative staging. The diagnostic accuracy of CT and SRS for detecting NF-pNET metastases was analysed. Altered TNM classification and changed clinical management were calculated. Changed management was defined as a change from surgical resection into systemic treatment or vice versa. NF-pNETs were defined as tumours without clinical symptoms of hormonal hypersecretion. Results: Overall, 62 patients with NF-pNET were included with a mean age of 57 years (SD: 12.4) 2 . In 28 patients (45%), CT and SRS were correct and in agreement in the detection of primary tumour/metastases. In 34 patients (55%), one of the techniques was incorrect and therefore, there was no agreement. SRS altered the TNM classification in 14 patients (23%) and clinical management in nine patients (15%). In patients without metastases on CT, SRS detected lymph node metastases in one patient. The sensitivity to detect the primary tumour with CT was 95% and with SRS was 73%. In detecting metastases, the sensitivity and specificity were both 85% for CT versus 80% and 90% for SRS. Conclusion: Overall, CT and SRS were in agreement in the detection of NF-pNET. In NF-pNET without suspicious metastatic lesions on CT, SRS has limited value. SRS may be indicated to confirm lesions suspicious for neuroendocrine tumours metastases. - Highlights: • In 28 patients (45%), CT and SRS were correct and in agreement in the detection of primary tumor/metastases. • In 34 patients (55%) one of the modalities was incorrect and therefore, there was no agreement. • Sensitivity to detect the primary tumor with CT and SRS were 95% versus 73

  3. ISAT: The mega-fauna acoustic tracking system

    KAUST Repository

    De la Torre, Pedro

    2013-06-01

    The acoustic tracking module of the Integrated Satellite and Acoustic Telemetry (iSAT) system is discussed in detail. iSAT is capable of detecting the relative direction of an acoustic source by measuring the order of arrival (OOA) of the acoustic signal to each hydrophone in a triangular array. The characteristics of the hydrophones, the projector, and the target acoustic signal used for iSAT are described. Initially it is designed to study the movements of whale sharks (Rhincodon typus), but it could potentially be used to describe high resolution movements of other marine species. © 2013 IEEE.

  4. Clinical implications of genomic alterations in the tumour and circulation of pancreatic cancer patients

    DEFF Research Database (Denmark)

    Sausen, Mark; Phallen, Jillian; Adleff, Vilmos

    2015-01-01

    tumour-specific mutations in the circulation of these patients. These analyses reveal somatic mutations in chromatin-regulating genes MLL, MLL2, MLL3 and ARID1A in 20% of patients that are associated with improved survival. We observe alterations in genes with potential therapeutic utility in over...... a third of cases. Liquid biopsy analyses demonstrate that 43% of patients with localized disease have detectable circulating tumour DNA (ctDNA) at diagnosis. Detection of ctDNA after resection predicts clinical relapse and poor outcome, with recurrence by ctDNA detected 6.5 months earlier than with CT...

  5. The Askin tumour. Neuroactodermic tumour of the thoracic wall

    International Nuclear Information System (INIS)

    Velazquez, P.; Nicolas, A. I.; Vivas, I.; Damaso Aquerreta, J.; Martinez-Cuesta, A.

    1999-01-01

    The Askin tumours is an extremely rare and malignant process in the thoracic pulmonary region during infancy and youth. The differential diagnosis has to be considered with other thoracic wall tumours that are more common in pediatrics like the undifferentiated neuroblastoma, the embionic rabdomiosarcoma, the Ewing sarcoma and the linfoma. A retrospective examination was carried out on 473 thoracic wall tumours from 1994 to 1997 at our centre, resulting in 4 patients with an anatomopathologically tested Askin tumour (ages from 13-21). All the cases were studied using simple radiography and CT. In two cases MRI was also used. The most common clinical manifestation was a palpable painful mass in the thoracic wall. In the simple radiograph the main finding was a large mass of extrapleural soft material, with costal destruction ( n=3) and a pleural effusion (n=2). In the CT study the mass was heterogeneous, with internal calcifications in one case. CT and MRI showed invasion in the mediastinum (n=1), medular channel (n=1) and phrenic and sulphrenic extension (n=1). The Askin tumour should be included in the differential diagnosis of thoracic wall masses in infant-youth ages. There are no specific morphological characteristics. Both CT and MRI are useful for the diagnosis, staging and follow up. (Author) 11 refs

  6. Enhanced acoustic sensing through wave compression and pressure amplification in anisotropic metamaterials.

    Science.gov (United States)

    Chen, Yongyao; Liu, Haijun; Reilly, Michael; Bae, Hyungdae; Yu, Miao

    2014-10-15

    Acoustic sensors play an important role in many areas, such as homeland security, navigation, communication, health care and industry. However, the fundamental pressure detection limit hinders the performance of current acoustic sensing technologies. Here, through analytical, numerical and experimental studies, we show that anisotropic acoustic metamaterials can be designed to have strong wave compression effect that renders direct amplification of pressure fields in metamaterials. This enables a sensing mechanism that can help overcome the detection limit of conventional acoustic sensing systems. We further demonstrate a metamaterial-enhanced acoustic sensing system that achieves more than 20 dB signal-to-noise enhancement (over an order of magnitude enhancement in detection limit). With this system, weak acoustic pulse signals overwhelmed by the noise are successfully recovered. This work opens up new vistas for the development of metamaterial-based acoustic sensors with improved performance and functionalities that are highly desirable for many applications.

  7. A signal amplification assay for HSV type 1 viral DNA detection using nanoparticles and direct acoustic profiling

    Directory of Open Access Journals (Sweden)

    Hammond Richard

    2010-02-01

    Full Text Available Abstract Background Nucleic acid based recognition of viral sequences can be used together with label-free biosensors to provide rapid, accurate confirmation of viral infection. To enhance detection sensitivity, gold nanoparticles can be employed with mass-sensitive acoustic biosensors (such as a quartz crystal microbalance by either hybridising nanoparticle-oligonucleotide conjugates to complimentary surface-immobilised ssDNA probes on the sensor, or by using biotin-tagged target oligonucleotides bound to avidin-modified nanoparticles on the sensor. We have evaluated and refined these signal amplification assays for the detection from specific DNA sequences of Herpes Simplex Virus (HSV type 1 and defined detection limits with a 16.5 MHz fundamental frequency thickness shear mode acoustic biosensor. Results In the study the performance of semi-homogeneous and homogeneous assay formats (suited to rapid, single step tests were evaluated utilising different diameter gold nanoparticles at varying DNA concentrations. Mathematical models were built to understand the effects of mass transport in the flow cell, the binding kinetics of targets to nanoparticles in solution, the packing geometries of targets on the nanoparticle, the packing of nanoparticles on the sensor surface and the effect of surface shear stiffness on the response of the acoustic sensor. This lead to the selection of optimised 15 nm nanoparticles that could be used with a 6 minute total assay time to achieve a limit of detection sensitivity of 5.2 × 10-12 M. Larger diameter nanoparticles gave poorer limits of detection than smaller particles. The limit of detection was three orders of magnitude lower than that observed using a hybridisation assay without nanoparticle signal amplification. Conclusions An analytical model was developed to determine optimal nanoparticle diameter, concentration and probe density, which allowed efficient and rapid optimisation of assay parameters

  8. Signal post-processing for acoustic velocimeters: detecting and replacing spikes

    International Nuclear Information System (INIS)

    Razaz, Mahdi; Kawanisi, Kiyosi

    2011-01-01

    Time series recorded by acoustic velocimeters are often affected by a combination of factors, including turbulent velocity fluctuations, Doppler noise and signal aliasing. Although it is not possible to find a comprehensive threshold for identifying spurious data, the present work attempts to describe an effective technique for detecting spikes. This technique is based on transforming data into wavelet space and thresholding the wavelet basis by a consistent threshold. The universal threshold modified by a robust scale estimator such as Q n is proven to work extremely well. The suggested methods for replacing identified spikes combine times series analyses (linear time series modelling or a Kalman predictor) with a straightforward method, polynomial interpolation, to generate substitutions retaining both the trends and the fluctuations in the surrounding clean data. Then, tests were performed to reveal the influence of replacing methods on the total number of detected spikes, required iterations and physical properties of the restored signal. From the overall results, it is inferred that using the wavelet-Q n as the detecting module and integrating it with linear time series modelling/Kalman filtering as the replacement module constitutes an effective despiking algorithm. This methodology is capable of restoring the contaminated signal in such a way that its statistical and physical properties correlate well with those of the original record

  9. Defect-detection algorithm for noncontact acoustic inspection using spectrum entropy

    Science.gov (United States)

    Sugimoto, Kazuko; Akamatsu, Ryo; Sugimoto, Tsuneyoshi; Utagawa, Noriyuki; Kuroda, Chitose; Katakura, Kageyoshi

    2015-07-01

    In recent years, the detachment of concrete from bridges or tunnels and the degradation of concrete structures have become serious social problems. The importance of inspection, repair, and updating is recognized in measures against degradation. We have so far studied the noncontact acoustic inspection method using airborne sound and the laser Doppler vibrometer. In this method, depending on the surface state (reflectance, dirt, etc.), the quantity of the light of the returning laser decreases and optical noise resulting from the leakage of light reception arises. Some influencing factors are the stability of the output of the laser Doppler vibrometer, the low reflective characteristic of the measurement surface, the diffused reflection characteristic, measurement distance, and laser irradiation angle. If defect detection depends only on the vibration energy ratio since the frequency characteristic of the optical noise resembles white noise, the detection of optical noise resulting from the leakage of light reception may indicate a defective part. Therefore, in this work, the combination of the vibrational energy ratio and spectrum entropy is used to judge whether a measured point is healthy or defective or an abnormal measurement point. An algorithm that enables more vivid detection of a defective part is proposed. When our technique was applied in an experiment with real concrete structures, the defective part could be extracted more vividly and the validity of our proposed algorithm was confirmed.

  10. The Contact State Monitoring for Seal End Faces Based on Acoustic Emission Detection

    Directory of Open Access Journals (Sweden)

    Xiaohui Li

    2016-01-01

    Full Text Available Monitoring the contact state of seal end faces would help the early warning of the seal failure. In the acoustic emission (AE detection for mechanical seal, the main difficulty is to reduce the background noise and to classify the dispersed features. To solve these problems and achieve higher detection rates, a new approach based on genetic particle filter with autoregression (AR-GPF and hypersphere support vector machine (HSSVM is presented. First, AR model is used to build the dynamic state space (DSS of the AE signal, and GPF is used for signal filtering. Then, multiple features are extracted, and a classification model based on HSSVM is constructed for state recognition. In this approach, AR-GPF is an excellent time-domain method for noise reduction, and HSSVM has advantage on those dispersed features. Finally experimental data shows that the proposed method can effectively detect the contact state of the seal end faces and has higher accuracy rates than some other existing methods.

  11. [Hydatidosis simulating a cardiac tumour with pulmonary metastases].

    Science.gov (United States)

    Martín-Izquierdo, Marta; Martín-Trenor, Alejandro

    2016-01-01

    The presence of multiple symptomatic pulmonary nodules and one cardiac tumour in a child requires urgent diagnosis and treatment. Until a few decades ago, the diagnosis of a cardiac tumour was difficult and was based on a high index of suspicion from indirect signs, and required angiocardiography for confirmation. Echocardiography and other imaging techniques have also helped in the detection of cardiac neoplasms. However, it is not always easy to make the correct diagnosis. The case is presented of a 12 year-old boy with pulmonary symptoms, and diagnosed with a cardiac tumour with lung metastases. The presence of numerous pulmonary nodules was confirmed in our hospital. The echocardiogram detected a solid cardiac nodule in the right ventricle. Magnetic resonance imaging confirmed the findings and the diagnosis. Puncture-aspiration of a lung nodule gave the diagnosis of hydatidosis. He underwent open-heart surgery with cardiac cyst resection and treated with anthelmintics. The lung cysts were then excised, and he recovered uneventfully. This child had multiple pulmonary nodules and a solid cardiac nodule, and was suspected of having a cardiac tumour with pulmonary metastases. However, given the clinical history, background and morphology of pulmonary nodules, another possible aetiology for consideration is echinococcosis. The clinical picture of cardiac hydatidosis and its complications is highly variable. The clinical history is essential in these cases, as well as having a high index of suspicion. Hydatidosis should be included in the differential diagnosis of a solid, echogenic, cardiac nodule. The treatment for cardiopulmonary hydatid cysts is surgical, followed by anthelmintics. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  12. Acoustic biosensors.

    Science.gov (United States)

    Fogel, Ronen; Limson, Janice; Seshia, Ashwin A

    2016-06-30

    Resonant and acoustic wave devices have been researched for several decades for application in the gravimetric sensing of a variety of biological and chemical analytes. These devices operate by coupling the measurand (e.g. analyte adsorption) as a modulation in the physical properties of the acoustic wave (e.g. resonant frequency, acoustic velocity, dissipation) that can then be correlated with the amount of adsorbed analyte. These devices can also be miniaturized with advantages in terms of cost, size and scalability, as well as potential additional features including integration with microfluidics and electronics, scaled sensitivities associated with smaller dimensions and higher operational frequencies, the ability to multiplex detection across arrays of hundreds of devices embedded in a single chip, increased throughput and the ability to interrogate a wider range of modes including within the same device. Additionally, device fabrication is often compatible with semiconductor volume batch manufacturing techniques enabling cost scalability and a high degree of precision and reproducibility in the manufacturing process. Integration with microfluidics handling also enables suitable sample pre-processing/separation/purification/amplification steps that could improve selectivity and the overall signal-to-noise ratio. Three device types are reviewed here: (i) bulk acoustic wave sensors, (ii) surface acoustic wave sensors, and (iii) micro/nano-electromechanical system (MEMS/NEMS) sensors. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  13. Development of active acoustic method for water leak detection of LMFBR steam generators

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Yoshida, Kazuo; Kinoshita, Izumi

    2001-01-01

    In order to prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of fast breeder reactors (FBRs), it is necessary to detect precisely and immediately the leakage of water from heat transfer tubes. Therefore, an active acoustic method, which detects the sound attenuation due to bubbles generated in the sodium-water reactions, is being developed. In this study, in order to evaluate the detection sensitivity of the active method, the signal processing methods for emitter and receiver and the detection method for leakage are investigated experimentally. In-water experiments performed by using an SG full-sector model that simulates the actual SGs. As an experimental result, the received sound attenuation for 10s was more than 10dB from air bubble injection when injected bubble of 10 l/s (equivalence water leak rate about 10 g/s.) The attenuation of sound are least affected by bubble injection position of heat transfer tubes bunch department. It is clarified that the background noise hardly influenced water leak detection performance as a result of having examined influence of background noise. (author)

  14. Perfusion imaging of parotid gland tumours: usefulness of arterial spin labeling for differentiating Warthin's tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki; Watanabe, Haruo [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Kanematsu, Masayuki [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Kajita, Kimihiro [Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Mizuta, Keisuke; Aoki, Mitsuhiro [Gifu University School of Medicine, Department of Otolaryngology, Gifu (Japan); Okuaki, Tomoyuki [Philips Healthcare, Tokyo (Japan)

    2015-11-15

    To assess prospectively the efficacy of arterial spin labelling (ASL) against conventional and diffusion-weighted (DW) MR imaging for differentiating parotid gland tumours. We included 10 pleomorphic adenomas, 12 Warthin's tumours, and nine malignant tumours of the parotid glands. Only tumours larger than 10 mm were included in this study. All parotid gland tumours underwent T1-weighted, T2-weighted, DW, and ASL imaging. Tumour-to-parotid gland signal intensity ratios (SIRs) and apparent diffusion coefficients (ADCs) of solid components were correlated with these pathologies. SIRs on T2-weighted images and ADCs were higher in pleomorphic adenomas than in Warthin's tumours (p <.01) and malignant tumours (p <.01). SIRs on ASL were higher in Warthin's tumours than in pleomorphic adenomas (p <.01) and malignant tumours (p <.05). Az value of SIRs on ASL for differentiating Warthin's tumours from the other pathologies was 0.982. The sensitivity, specificity, and accuracy of SIRs on ASL for the diagnosis of Warthin's tumours at an optimal SIR threshold of over 8.70 were 91.7 %, 94.7 %, and 93.5 %, respectively. ASL with SIR measurements could non-invasively evaluate tumour blood flow of parotid gland tumours and differentiate Warthin's tumours from pleomorphic adenomas and malignant tumours. (orig.)

  15. When should genetic testing be performed in patients with neuroendocrine tumours?

    Science.gov (United States)

    O'Shea, Triona; Druce, Maralyn

    2017-12-01

    Neuroendocrine tumours (NETs) are a heterogenous group of tumours arising from neuroendocrine cells in several sites around the body. They include tumours of the gastroenteropancreatic system, phaeochromocytoma and paraganglioma and medullary thyroid cancer. In recent years, it has become increasingly apparent that a number of these tumours arise as a result of germline genetic mutations and are inherited in an autosomal dominant pattern. The number of genes implicated is increasing rapidly. Identifying which patients are likely to have a germline mutation enables clinicians to counsel patients adequately about their future disease risk, and allows for earlier detection of at-risk patients through family screening. The institution of screening and surveillance programmes may in turn lead to a major shift in presentation patterns for some of these tumours. In this review, we examine the features which may lead a clinician to suspect that a patient may have an inherited cause of a NET and we outline which underlying conditions should be suspected. We also discuss what type of screening may be appropriate in a variety of situations.

  16. Targeting of liver tumour in rats by selective delivery of holmium-166 loaded microspheres: a biodistribution study

    Energy Technology Data Exchange (ETDEWEB)

    Nijsen, F.; Rook, D.; Zonnenberg, B.; Klerk, J. de; Rijk, P. van; Schip, F. van het [Dept. of Nuclear Medicine, University Medical Center, Utrecht (Netherlands); Brandt, C. [Animal Inst., Utrecht Univ. (Netherlands); Meijer, R. [Dept. of Radiology, Univ. Medical Center, Utrecht (Netherlands); Dullens, H. [Dept. of Pathology, Univ. Medical Center, Utrecht (Netherlands); Hennink, W. [Dept. of Pharmaceutics, Utrecht Univ. (Netherlands)

    2001-06-01

    Intra-arterial administration of beta-emitting particles that become trapped in the vascular bed of a tumour and remain there while delivering high doses, represents a unique approach in the treatment of both primary and metastatic liver tumours. Studies on selective internal radiation therapy of colorectal liver metastases using yttrium-90 glass microspheres have shown encouraging results. This study describes the biodistribution of 40-{mu}m poly lactic acid microspheres loaded with radioactive holmium-166, after intra-arterial administration into the hepatic artery of rats with implanted liver tumours. Radioactivity measurements showed >95% retention of injected activity in the liver and its resident tumour. The average activity detected in other tissues was {<=}0.1%ID/g, with incidental exceptions in the lungs and stomach. Very little {sup 166}Ho activity was detected in kidneys (<0.1%ID/g), thereby indicating the stability of the microspheres in vivo. Tumour targeting was very effective, with a mean tumour to liver ratio of 6.1{+-}2.9 for rats with tumour (n=15) versus 0.7{+-}0.5 for control rats (n=6; P<0.001). These ratios were not significantly affected by the use of adrenaline. Histological analysis showed that five times as many large (>10) and medium-sized (4-9) clusters of microspheres were present within tumour and peritumoural tissue, compared with normal liver. Single microspheres were equally dispersed throughout the tumour, as well as normal liver parenchyma. (orig.)

  17. Tumour seeding after percutaneous cryoablation for hepatocellular carcinoma

    Science.gov (United States)

    Wang, Chun-Ping; Wang, Hong; Qu, Jian-Hui; Lu, Yin-Ying; Bai, Wen-Lin; Dong, Zheng; Gao, Xu-Dong; Rong, Guang-Hua; Zeng, Zhen; Yang, Yong-Ping

    2012-01-01

    AIM: To assess the rate and risk factors for tumour seeding in a large cohort of patients. METHODS: Over an 8-year period, 1436 hepatocellular carcinoma (HCC) patients with 2423 tumour nodules underwent 3015 image-guided percutaneous cryoablation sessions [1215 guided by ultrasonography and 221 by spiral computed tomography (CT)]. Follow-up CT or magnetic resonance imaging was performed every 3 mo. The detailed clinical data were recorded to analyse the risk factors for seeding. RESULTS: The median follow-up time was 18 (range 1-90) mo. Seeding was detected in 11 patients (0.76%) at 1-24 (median 6.0) mo after cryoablation. Seeding occurred along the needle tract in 10 patients and at a distant location in 1 patient. Seeded tumours usually showed similar imaging and histopathological features to the primary HCCs. Univariate analyses identified subcapsular tumour location and direct subcapsular needle insertion as risk factors for seeding. Multivariate analysis showed that only direct subcapsular needle insertion was an independent risk factor for seeding (P = 0.017; odds ratio 2.57; 95%CI: 1.47-3.65). Seeding after cryoablation occurred earlier in patients with poorly differentiated HCC than those with well or moderately differentiated HCC [1.33 ± 0.577 mo vs 11.12 ± 6.896 mo; P = 0.042; 95%CI: (-19.115)-(-0.468)]. CONCLUSION: The risk of seeding after cryoablation for HCC is small. Direct puncture of subcapsular tumours should be avoided to minimise seeding. PMID:23236233

  18. Diagnosis of bladder tumours in patients with macroscopic haematuria

    DEFF Research Database (Denmark)

    Gandrup, Karen L; Løgager, Vibeke B; Bretlau, Thomas

    2015-01-01

    patients underwent CTU, MRU and flexible cystoscopy. Two uroradiologists individually reviewed the images without any clinical information, using a questionnaire. Patient records and pathology reports were also reviewed. RESULTS: At flexible cystoscopy, MRU and CTU, 32, 19 and 15 bladder lesions were...... identified, respectively. Histopathology showed that 13 of the 29 biopsied lesions were transitional cell carcinomas. Compared with the histopathology, the sensitivity and specificity for detection of tumours by CTU and MRU were 61.5% and 94.9%, and 79.9% and 93.4%, respectively. False-positive detection...... of bladder tumours, compared with histopathology, was reported in seven CTUs and nine MRUs, whereas the number of false-negative findings was five for CTUs and three for MRUs. CONCLUSIONS: Split-bolus CTU or MRU cannot replace cystoscopy in cases of macroscopic haematuria. MRU has a higher sensitivity than...

  19. Usefulness of low-dose CT in the detection of pulmonary metastasis of gestational trophoblastic tumours

    International Nuclear Information System (INIS)

    Xu, X.J.; Lou, F.L.; Zhang, M.M.; Pan, Z.M.; Zhang, L.

    2007-01-01

    Aim: To determine whether a low-dose spiral chest computed tomography (CT) examination could replace standard-dose chest CT in detecting pulmonary metastases in patients with gestational trophoblastic tumour (GTT). Materials and methods: In a prospective investigation, 67 chest CT examinations of 39 GTT patients were undertaken. All the patients underwent CT examinations using standard-dose (150 mAs, pitch 1, standard reconstruction algorithm) and low-dose (40 mAs, pitch 2, bone reconstruction algorithm) protocols. Two radiologists interpreted images independently. A metastasis was defined as a nodule within lung parenchyma that could not be attributed to a pulmonary vessel. The number of metastases detected with each protocol was recorded. The size of each lesion was measured and categorized as <5, 5-9.9, and ≥10 mm. Wilcoxon's signed rank test was used to assess the difference between the numbers of lesion detected by the two protocols. Results: The CT dose index (CTDI) for the standard-dose and low-dose CT protocols was 10.4 mGy and 1.4 mGy, respectively. One thousand, six hundred, and eighty-two metastases were detected by standard-dose CT, and 1460 lesions by the low-dose protocol. The numbers detected by low-dose CT were significantly less than those detected by standard-dose CT (Z = -3.776, p < 0.001), especially for nodules smaller than 5 mm (Z = -4.167, p < 0.001). However, the disease staging and risk score of the patients were not affected by use of the low-dose protocol. Conclusion: Low-dose chest CT can be used as a staging and follow-up procedure for patients with GTT

  20. Leak Detection in Water-Filled Small-Diameter Polyethylene Pipes by Means of Acoustic Emission Measurements

    OpenAIRE

    Alberto Martini; Marco Troncossi; Alessandro Rivola

    2016-01-01

    The implementation of effective strategies to manage leaks represents an essential goal for all utilities involved with drinking water supply in order to reduce water losses affecting urban distribution networks. This study concerns the early detection of leaks occurring in small-diameter customers’ connections to water supply networks. An experimental campaign was carried out in a test bed to investigate the sensitivity of Acoustic Emission (AE) monitoring to water leaks. Damages were artifi...

  1. Breast cancer detection using time reversal

    Science.gov (United States)

    Sheikh Sajjadieh, Mohammad Hossein

    Breast cancer is the second leading cause of cancer death after lung cancer among women. Mammography and magnetic resonance imaging (MRI) have certain limitations in detecting breast cancer, especially during its early stage of development. A number of studies have shown that microwave breast cancer detection has potential to become a successful clinical complement to the conventional X-ray mammography. Microwave breast imaging is performed by illuminating the breast tissues with an electromagnetic waveform and recording its reflections (backscatters) emanating from variations in the normal breast tissues and tumour cells, if present, using an antenna array. These backscatters, referred to as the overall (tumour and clutter) response, are processed to estimate the tumour response, which is applied as input to array imaging algorithms used to estimate the location of the tumour. Due to changes in the breast profile over time, the commonly utilized background subtraction procedures used to estimate the target (tumour) response in array processing are impractical for breast cancer detection. The thesis proposes a new tumour estimation algorithm based on a combination of the data adaptive filter with the envelope detection filter (DAF/EDF), which collectively do not require a training step. After establishing the superiority of the DAF/EDF based approach, the thesis shows that the time reversal (TR) array imaging algorithms outperform their conventional conterparts in detecting and localizing tumour cells in breast tissues at SNRs ranging from 15 to 30dB.

  2. Acoustic emission from polycrystalline graphites

    International Nuclear Information System (INIS)

    Ioka, I.; Yoda, S.; Oku, T.; Miyamoto, Y.

    1987-01-01

    Acoustic emission was monitored from polycrystalline graphites with different microstructure (pore size and pore volume) subjected to compressive loading. The graphites used in this study comprised five brands, that is, PGX, ISEM-1, IG-11, IG-15, and ISO-88. A root mean square (RMS) voltage and event counts of acoustic emission for graphites were measured during compressive loading. The acoustic emission was measured using a computed-based data acquisition and analysis system. The graphites were first deformed up to 80 % of the average fracture stress, then unloaded and reloaded again until the fracture occured. During the first loading, the change in RMS voltage for acoustic emission was detected from the initial stage. During the unloading, the RMS voltage became zero level as soon as the applied stress was released and then gradually rose to a peak and declined. The behavior indicated that the reversed plastic deformation occured in graphites. During the second loading, the RMS voltage gently increased until the applied stress exceeded the maximum stress of the first loading; there is no Kaiser effect in the graphites. A bicrystal model could give a reasonable explanation of this results. The empirical equation between the ratio of σ AE to σ f and σ f was obtained. It is considered that the detection of microfracture by the acoustic emission technique is effective in macrofracture prediction of polycrystalline graphites. (author)

  3. Simulation-based design of a steerable acoustic warning device to increase (H)EV detectability while reducing urban noise pollution

    NARCIS (Netherlands)

    Van Genechten, B.; Berkhoff, Arthur P.

    2014-01-01

    This paper describes the simulation-based design methodology used in the eVADER project for the development of targeted acoustic warning devices for increased detectability of Hybrid and Electric Vehicles (HEVs) while, at the same time, reducing urban noise pollution compared to conventional

  4. An acoustic emission study of plastic deformation in polycrystalline aluminium

    Science.gov (United States)

    Bill, R. C.; Frederick, J. R.; Felbeck, D. K.

    1979-01-01

    Acoustic emission experiments were performed on polycrystalline and single crystal 99.99% aluminum while undergoing tensile deformation. It was found that acoustic emission counts as a function of grain size showed a maximum value at a particular grain size. Furthermore, the slip area associated with this particular grain size corresponded to the threshold level of detectability of single dislocation slip events. The rate of decline in acoustic emission activity as grain size is increased beyond the peak value suggests that grain boundary associated dislocation sources are giving rise to the bulk of the detected acoustic emissions.

  5. Acoustic holograms of active regions

    International Nuclear Information System (INIS)

    Chou, Dean-Yi

    2008-01-01

    We propose a method to study solar magnetic regions in the solar interior with the principle of optical holography. A magnetic region in the solar interior scatters the solar background acoustic waves. The scattered waves and background waves could form an interference pattern on the solar surface. We investigate the feasibility of detecting this interference pattern on the solar surface, and using it to construct the three-dimensional scattered wave from the magnetic region with the principle of optical holography. In solar acoustic holography, the background acoustic waves play the role of reference wave; the magnetic region plays the role of the target object; the interference pattern, acoustic power map, on the solar surface plays the role of the hologram.

  6. Acoustic holograms of active regions

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Dean-Yi [Physics Department, National Tsing Hua University, Hsinchu, 30013, Taiwan (China)], E-mail: chou@phys.nthu.edu.tw

    2008-10-15

    We propose a method to study solar magnetic regions in the solar interior with the principle of optical holography. A magnetic region in the solar interior scatters the solar background acoustic waves. The scattered waves and background waves could form an interference pattern on the solar surface. We investigate the feasibility of detecting this interference pattern on the solar surface, and using it to construct the three-dimensional scattered wave from the magnetic region with the principle of optical holography. In solar acoustic holography, the background acoustic waves play the role of reference wave; the magnetic region plays the role of the target object; the interference pattern, acoustic power map, on the solar surface plays the role of the hologram.

  7. Experimental tumour treatment

    International Nuclear Information System (INIS)

    1985-08-01

    This report of 1984 is the seventh in a series and presents that year's results of continuous studies in the domain of experimental tumour radiotherapy. In the year under review, more personnel has been available for the studies, and the scientific programmes for the assessment of acute and chronic side effects of radiotherapies have been extended. New models have been developed, among them a first system based on animal experiments, for quantifying the mucositis of the oral and pharyngeal mucosa, a limiting condition in the radiotherapy of head and throat tumours. Another significant advancement is a model for quantification of chronical damage to the ureter, which still is a serious problem in the radiotherapy of gynaecological tumours. The 1984 experimental tumour studies have been mainly devoted to the repopulation and split-dose recovery in various tumours, concentrating on dose fractionation as one of the major problems studies. Particular interest has been attached to the processes involved in treatments over several weeks with a daily effective dose of 2 Gy. (orig./MG) [de

  8. Acoustic Emission Detection of Macro-Cracks on Engraving Tool Steel Inserts during the Injection Molding Cycle Using PZT Sensors

    Directory of Open Access Journals (Sweden)

    Aleš Hančič

    2013-05-01

    Full Text Available This paper presents an improved monitoring system for the failure detection of engraving tool steel inserts during the injection molding cycle. This system uses acoustic emission PZT sensors mounted through acoustic waveguides on the engraving insert. We were thus able to clearly distinguish the defect through measured AE signals. Two engraving tool steel inserts were tested during the production of standard test specimens, each under the same processing conditions. By closely comparing the captured AE signals on both engraving inserts during the filling and packing stages, we were able to detect the presence of macro-cracks on one engraving insert. Gabor wavelet analysis was used for closer examination of the captured AE signals’ peak amplitudes during the filling and packing stages. The obtained results revealed that such a system could be used successfully as an improved tool for monitoring the integrity of an injection molding process.

  9. In vivo characterisation of soft tissue tumours by 1.5-T proton MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.; Mazzetti, S.; Grignani, G.; Rosa, G.De; Aglietta, M.; Anselmetti, G.C.; Stasi, M.; Regge, D. [Institute for Cancer Research and Treatment (IRCC), Candiolo, Torino (Italy)

    2012-05-15

    To determine whether proton magnetic resonance spectroscopy (1H-MRS) can help differentiate between benign and malignant soft tissue lesions, and to assess if there is a correlation between 1H-MRS data and the mitotic index. MR measurements were performed in 43 patients with soft tissue tumours >15 mm in diameter. Six cases were excluded for technical failure. Examinations were performed at 1.5 T using a single-voxel point resolved spectroscopy sequence (PRESS) with TR/TE = 2000/150 ms. The volume of interest was positioned within the lesion avoiding inclusion of necrotic regions. In all patients, a histological diagnosis was obtained and the corresponding mitotic index was also computed. 1H-MRS results and histopathological findings were compared using the chi-squared test and correlation coefficient. Choline was detected in 18/19 patients with malignant tumours and in 3/18 patients with benign lesions. The three benign lesions included one desmoid tumour, one ossificans myositis and one eccrine spiradenoma. Choline was not detected in 15 patients with benign lesions or in one patient with dermatofibrosarcoma protuberans. Resulting 1H-MRS sensitivity and specificity were 95% and 83% respectively. Absence of choline peak is highly predictive of benign tumours suggesting that 1H-MRS can help to differentiate malignant from benign tumours. (orig.)

  10. In vivo characterisation of soft tissue tumours by 1.5-T proton MR spectroscopy

    International Nuclear Information System (INIS)

    Russo, F.; Mazzetti, S.; Grignani, G.; Rosa, G.De; Aglietta, M.; Anselmetti, G.C.; Stasi, M.; Regge, D.

    2012-01-01

    To determine whether proton magnetic resonance spectroscopy (1H-MRS) can help differentiate between benign and malignant soft tissue lesions, and to assess if there is a correlation between 1H-MRS data and the mitotic index. MR measurements were performed in 43 patients with soft tissue tumours >15 mm in diameter. Six cases were excluded for technical failure. Examinations were performed at 1.5 T using a single-voxel point resolved spectroscopy sequence (PRESS) with TR/TE = 2000/150 ms. The volume of interest was positioned within the lesion avoiding inclusion of necrotic regions. In all patients, a histological diagnosis was obtained and the corresponding mitotic index was also computed. 1H-MRS results and histopathological findings were compared using the chi-squared test and correlation coefficient. Choline was detected in 18/19 patients with malignant tumours and in 3/18 patients with benign lesions. The three benign lesions included one desmoid tumour, one ossificans myositis and one eccrine spiradenoma. Choline was not detected in 15 patients with benign lesions or in one patient with dermatofibrosarcoma protuberans. Resulting 1H-MRS sensitivity and specificity were 95% and 83% respectively. Absence of choline peak is highly predictive of benign tumours suggesting that 1H-MRS can help to differentiate malignant from benign tumours. (orig.)

  11. Damage Detection Method of Wind Turbine Blade Using Acoustic Emission Signal Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Han, Byeong Hee; Yoon, Dong JIn [Korea Research Institute of Standards and Seience, Daejeon (Korea, Republic of)

    2011-02-15

    Acoustic emission(AE) has emerged as a powerful nondestructive tool to detect any further growth or expansion of preexisting defects or to characterize failure mechanisms. Recently, this kind of technique, that is an in-situ monitoring of inside damages of materials or structures, becomes increasingly popular for monitoring the integrity of large structures like a huge wind turbine blade. Therefore, it is required to find a symptom of damage propagation before catastrophic failure through a continuous monitoring. In this study, a new damage location method has been proposed by using signal napping algorithm, and an experimental verification is conducted by using small wind turbine blade specimen: a part of 750 kW real blade. The results show that this new signal mapping method has high advantages such as a flexibility for sensor location, improved accuracy, high detectability. The newly proposed method was compared with traditional AE source location method based on arrival time difference

  12. Acoustic spin pumping in magnetoelectric bulk acoustic wave resonator

    Directory of Open Access Journals (Sweden)

    N. I. Polzikova

    2016-05-01

    Full Text Available We present the generation and detection of spin currents by using magnetoelastic resonance excitation in a magnetoelectric composite high overtone bulk acoustic wave (BAW resonator (HBAR formed by a Al-ZnO-Al-GGG-YIG-Pt structure. Transversal BAW drives magnetization oscillations in YIG film at a given resonant magnetic field, and the resonant magneto-elastic coupling establishes the spin-current generation at the Pt/YIG interface. Due to the inverse spin Hall effect (ISHE this BAW-driven spin current is converted to a dc voltage in the Pt layer. The dependence of the measured voltage both on magnetic field and frequency has a resonant character. The voltage is determined by the acoustic power in HBAR and changes its sign upon magnetic field reversal. We compare the experimentally observed amplitudes of the ISHE electrical field achieved by our method and other approaches to spin current generation that use surface acoustic waves and microwave resonators for ferromagnetic resonance excitation, with the theoretically expected values.

  13. Acoustic spin pumping in magnetoelectric bulk acoustic wave resonator

    Energy Technology Data Exchange (ETDEWEB)

    Polzikova, N. I., E-mail: polz@cplire.ru; Alekseev, S. G.; Pyataikin, I. I.; Kotelyanskii, I. M.; Luzanov, V. A.; Orlov, A. P. [Kotel’nikov Institute of Radio Engineering and Electronics of Russian Academy of Sciences, Mokhovaya 11, building 7, Moscow, 125009 (Russian Federation)

    2016-05-15

    We present the generation and detection of spin currents by using magnetoelastic resonance excitation in a magnetoelectric composite high overtone bulk acoustic wave (BAW) resonator (HBAR) formed by a Al-ZnO-Al-GGG-YIG-Pt structure. Transversal BAW drives magnetization oscillations in YIG film at a given resonant magnetic field, and the resonant magneto-elastic coupling establishes the spin-current generation at the Pt/YIG interface. Due to the inverse spin Hall effect (ISHE) this BAW-driven spin current is converted to a dc voltage in the Pt layer. The dependence of the measured voltage both on magnetic field and frequency has a resonant character. The voltage is determined by the acoustic power in HBAR and changes its sign upon magnetic field reversal. We compare the experimentally observed amplitudes of the ISHE electrical field achieved by our method and other approaches to spin current generation that use surface acoustic waves and microwave resonators for ferromagnetic resonance excitation, with the theoretically expected values.

  14. Targeting of breast metastases using a viral gene vector with tumour-selective transcription.

    LENUS (Irish Health Repository)

    Rajendran, Simon

    2012-01-31

    BACKGROUND: Adeno-associated virus (AAV) vectors have significant potential as gene delivery vectors for cancer gene therapy. However, broad AAV2 tissue tropism results in nonspecific gene expression. MATERIALS AND METHODS: We investigated use of the C-X-C chemokine receptor type 4 (CXCR4) promoter to restrict AAV expression to tumour cells, in subcutaneous MCF-7 xenograft mouse models of breast cancer and in patient samples, using bioluminescent imaging and flow cytometric analysis. RESULTS: Higher transgene expression levels were observed in subcutaneous MCF-7 tumours relative to normal tissue (muscle) using the CXCR4 promoter, unlike a ubiquitously expressing Cytomegalovirus promoter construct, with preferential AAVCXCR4 expression in epithelial tumour and CXCR4-positive cells. Transgene expression following intravenously administered AAVCXCR4 in a model of liver metastasis was detected specifically in livers of tumour bearing mice. Ex vivo analysis using patient samples also demonstrated higher AAVCXCR4 expression in tumour compared with normal liver tissue. CONCLUSION: This study demonstrates for the first time, the potential for systemic administration of AAV2 vector for tumour-selective gene therapy.

  15. Identification of acoustic wave propagation in a duct line and its application to detection of impact source location based on signal processing

    International Nuclear Information System (INIS)

    Shin, Yong Woo; Kim, Min Soo; Lee, Sang Kwon

    2010-01-01

    For the detection of the impact location in a pipeline system, the correlation method has been the conventional method. For the application of the correlation method, the diameter of a duct should be small so that the acoustic wave inside the duct can propagate with nondispersive characteristics, in the form of, for example, a plane wave. This correlation method calculates the cross-correlation between acoustic waves measured at two acceleration sensors attached to a buried duct. It also gives information about the arrival time delay of an acoustic wave between two sensors. These arrival time delays are used for the estimation of the impact location. However, when the diameter of the duct is large, the acoustic waves inside the duct propagate with dispersive characteristics owing to the reflection of the acoustic wave off of the wall of the duct. This dispersive characteristic is related to the acoustic modes inside a duct. Therefore, the correlation method does not work correctly for the detection of the impact location. This paper proposes new methods of accurately measuring the arrival time delay between two sensors attached to duct line system. This method is based on the time-frequency analyses of the short time Fourier transform (STFT) and continuous wavelet transform (CWT). These methods can discriminate direct waves (non-dispersive waves) and reflective waves (dispersive waves) from the measured wave signals through the time-frequency analysis. The direct wave or the reflective wave is used to estimate the arrival time delay. This delay is used for the identification of the impact location. This systematic method can predict the impact location due to the impact forces of construction equipment with more accuracy than the correlation method

  16. Autologous monoclonal antibodies recognize tumour-associated antigens in X-irradiated C57BL/6 mice

    Energy Technology Data Exchange (ETDEWEB)

    Artus, A; Guillemain, B; Legrand, E; Astier-Gin, T; Mamoun, R; Duplan, J -F

    1986-09-01

    X-irradiation of C57BL/6 mice induces thymic lymphosarcomas which sometimes contain retroviruses which upon injection into normal mice mimic the effect of the irradiation. We examined whether specific antigenicities, viral or cellular, were expressed by tumour cells that could be recognized by antibodies from the irradiated animals. We developed monoclonal antibodies (MAbs) using splenocytes of the diseased animal. The reactivity of such MAbs towards thymoma cell lines established in vitro was investigated by means of an ELISA. At least 10 antibody specificities were detected on the 13 tumours investigated, allowing separation of the MAbs into three classes: (i) those recognizing the autologous tumour, heterologous tumours as well as normal thymic tissue, (ii) those specific for the autologous tumour, and (iii) those specific for one tumour, but not ones of autologous origin. The last two classes corresponded to specific tumour-associated antigens. Our panel of MAbs defined each tumour by the particular pattern of antigens harboured. It is striking that most of the antigens were present in the normal thymus and that only two tumours had additional antigenicities. Additionally, quantitative variations were observed in the levels of expression of these antigens.

  17. Tracking errors in a prototype real-time tumour tracking system

    International Nuclear Information System (INIS)

    Sharp, Gregory C; Jiang, Steve B; Shimizu, Shinichi; Shirato, Hiroki

    2004-01-01

    In motion-compensated radiation therapy, radio-opaque markers can be implanted in or near a tumour and tracked in real-time using fluoroscopic imaging. Tracking these implanted markers gives highly accurate position information, except when tracking fails due to poor or ambiguous imaging conditions. This study investigates methods for automatic detection of tracking errors, and assesses the frequency and impact of tracking errors on treatments using the prototype real-time tumour tracking system. We investigated four indicators for automatic detection of tracking errors, and found that the distance between corresponding rays was most effective. We also found that tracking errors cause a loss of gating efficiency of between 7.6 and 10.2%. The incidence of treatment beam delivery during tracking errors was estimated at between 0.8% and 1.25%

  18. Adapting radiotherapy to hypoxic tumours

    International Nuclear Information System (INIS)

    Malinen, Eirik; Soevik, Aste; Hristov, Dimitre; Bruland, Oeyvind S; Olsen, Dag Rune

    2006-01-01

    In the current work, the concepts of biologically adapted radiotherapy of hypoxic tumours in a framework encompassing functional tumour imaging, tumour control predictions, inverse treatment planning and intensity modulated radiotherapy (IMRT) were presented. Dynamic contrast enhanced magnetic resonance imaging (DCEMRI) of a spontaneous sarcoma in the nasal region of a dog was employed. The tracer concentration in the tumour was assumed related to the oxygen tension and compared to Eppendorf histograph measurements. Based on the pO 2 -related images derived from the MR analysis, the tumour was divided into four compartments by a segmentation procedure. DICOM structure sets for IMRT planning could be derived thereof. In order to display the possible advantages of non-uniform tumour doses, dose redistribution among the four tumour compartments was introduced. The dose redistribution was constrained by keeping the average dose to the tumour equal to a conventional target dose. The compartmental doses yielding optimum tumour control probability (TCP) were used as input in an inverse planning system, where the planning basis was the pO 2 -related tumour images from the MR analysis. Uniform (conventional) and non-uniform IMRT plans were scored both physically and biologically. The consequences of random and systematic errors in the compartmental images were evaluated. The normalized frequency distributions of the tracer concentration and the pO 2 Eppendorf measurements were not significantly different. 28% of the tumour had, according to the MR analysis, pO 2 values of less than 5 mm Hg. The optimum TCP following a non-uniform dose prescription was about four times higher than that following a uniform dose prescription. The non-uniform IMRT dose distribution resulting from the inverse planning gave a three times higher TCP than that of the uniform distribution. The TCP and the dose-based plan quality depended on IMRT parameters defined in the inverse planning procedure

  19. Adapting radiotherapy to hypoxic tumours

    Science.gov (United States)

    Malinen, Eirik; Søvik, Åste; Hristov, Dimitre; Bruland, Øyvind S.; Rune Olsen, Dag

    2006-10-01

    In the current work, the concepts of biologically adapted radiotherapy of hypoxic tumours in a framework encompassing functional tumour imaging, tumour control predictions, inverse treatment planning and intensity modulated radiotherapy (IMRT) were presented. Dynamic contrast enhanced magnetic resonance imaging (DCEMRI) of a spontaneous sarcoma in the nasal region of a dog was employed. The tracer concentration in the tumour was assumed related to the oxygen tension and compared to Eppendorf histograph measurements. Based on the pO2-related images derived from the MR analysis, the tumour was divided into four compartments by a segmentation procedure. DICOM structure sets for IMRT planning could be derived thereof. In order to display the possible advantages of non-uniform tumour doses, dose redistribution among the four tumour compartments was introduced. The dose redistribution was constrained by keeping the average dose to the tumour equal to a conventional target dose. The compartmental doses yielding optimum tumour control probability (TCP) were used as input in an inverse planning system, where the planning basis was the pO2-related tumour images from the MR analysis. Uniform (conventional) and non-uniform IMRT plans were scored both physically and biologically. The consequences of random and systematic errors in the compartmental images were evaluated. The normalized frequency distributions of the tracer concentration and the pO2 Eppendorf measurements were not significantly different. 28% of the tumour had, according to the MR analysis, pO2 values of less than 5 mm Hg. The optimum TCP following a non-uniform dose prescription was about four times higher than that following a uniform dose prescription. The non-uniform IMRT dose distribution resulting from the inverse planning gave a three times higher TCP than that of the uniform distribution. The TCP and the dose-based plan quality depended on IMRT parameters defined in the inverse planning procedure (fields

  20. Distributed acoustic sensing for pipeline monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hill, David; McEwen-King, Magnus [OptaSense, QinetiQ Ltd., London (United Kingdom)

    2009-07-01

    Optical fibre is deployed widely across the oil and gas industry. As well as being deployed regularly to provide high bandwidth telecommunications and infrastructure for SCADA it is increasingly being used to sense pressure, temperature and strain along buried pipelines, on subsea pipelines and downhole. In this paper we present results from the latest sensing capability using standard optical fibre to detect acoustic signals along the entire length of a pipeline. In Distributed Acoustic Sensing (DAS) an optical fibre is used for both sensing and telemetry. In this paper we present results from the OptaSense{sup TM} system which has been used to detect third party intervention (TPI) along buried pipelines. In a typical deployment the system is connected to an existing standard single-mode fibre, up to 50km in length, and was used to independently listen to the acoustic / seismic activity at every 10 meter interval. We will show that through the use of advanced array processing of the independent, simultaneously sampled channels it is possible to detect and locate activity within the vicinity of the pipeline and through sophisticated acoustic signal processing to obtain the acoustic signature to classify the type of activity. By combining spare fibre capacity in existing buried fibre optic cables; processing and display techniques commonly found in sonar; and state-of-the-art in fibre-optic distributed acoustic sensing, we will describe the new monitoring capabilities that are available to the pipeline operator. Without the expense of retrofitting sensors to the pipeline, this technology can provide a high performance, rapidly deployable and cost effective method of providing gapless and persistent monitoring of a pipeline. We will show how this approach can be used to detect, classify and locate activity such as; third party interference (including activity indicative of illegal hot tapping); real time tracking of pigs; and leak detection. We will also show how an

  1. Platelet-activating factor receptor (PAF-R)-dependent pathways control tumour growth and tumour response to chemotherapy

    International Nuclear Information System (INIS)

    Oliveira, Soraya I de; Andrade, Luciana NS; Onuchic, Ana C; Nonogaki, Sueli; Fernandes, Patrícia D; Pinheiro, Mônica C; Rohde, Ciro BS; Chammas, Roger; Jancar, Sonia

    2010-01-01

    Phagocytosis of apoptotic cells by macrophages induces a suppressor phenotype. Previous data from our group suggested that this occurs via Platelet-activating factor receptor (PAF-R)-mediated pathways. In the present study, we investigated the impact of apoptotic cell inoculation or induction by a chemotherapeutic agent (dacarbazine, DTIC) on tumour growth, microenvironmental parameters and survival, and the effect of treatment with a PAF-R antagonist (WEB2170). These studies were performed in murine tumours: Ehrlich Ascitis Tumour (EAT) and B16F10 melanoma. Tumour growth was assessed by direct counting of EAT cells in the ascitis or by measuring the volume of the solid tumour. Parameters of the tumour microenvironment, such as the frequency of cells expressing cyclo-oxygenase-2 (COX-2), caspase-3 and galectin-3, and microvascular density, were determined by immunohistochemistry. Levels of vascular endothelium growth factor (VEGF) and prostaglandin E2 (PGE2) were determined by ELISA, and levels of nitric oxide (NO) by Griess reaction. PAF-R expression was analysed by immunohistochemistry and flow cytometry. Inoculation of apoptotic cells before EAT implantation stimulated tumour growth. This effect was reversed by in vivo pre-treatment with WEB2170. This treatment also reduced tumour growth and modified the microenvironment by reducing PGE2, VEGF and NO production. In B16F10 melanoma, WEB2170 alone or in association with DTIC significantly reduced tumour volume. Survival of the tumour-bearing mice was not affected by WEB2170 treatment but was significantly improved by the combination of DTIC with WEB2170. Tumour microenvironment elements were among the targets of the combination therapy since the relative frequency of COX-2 and galectin-3 positive cells and the microvascular density within the tumour mass were significantly reduced by treatment with WEB2170 or DTIC alone or in combination. Antibodies to PAF-R stained the cells from inside the tumour, but not the

  2. Tumour metastasis-associated gene profiling using one-dimensional microfluidic beads array

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Great efforts have been made on the early diagnosis and molecular mechanism research of tumour metastasis in recent years. In this paper, based on the one-dimensional microfluidic beads array, a novel platform for tumour metastasis-associated genes profiling has been developed by depositing nucleic acids functional beads in the microchannel. This platform is sensitive (limit of detection: 0.02 nmol/L) and can perform mRNAs analysis without PCR. Two human colon cancer cell lines (primary and metastatic) from the same patient were used as a model, and transcriptional expression profiling of multiple tumour metastasis-associated genes in these two cell lines was successfully achieved. Furthermore, the results obtained on the beads array were validated by RT-PCR. This novel beads array has advantages of high sensitivity, little sample consumption, short assay time, low cost and high throughput capability. It holds the potential in early diagnosis and mechanism research of tumour metastasis.

  3. Tumour and tumour-like lesions of the patella - a multicentre experience

    International Nuclear Information System (INIS)

    Singh, J.; James, S.L.; Davies, A.M.; Kroon, H.M.; Woertler, K.; Anderson, S.E.

    2009-01-01

    Fifty-nine cases of lesions presenting in the patella were identified after review of the databases of four European bone tumour registries. Of the 59 cases, 46% were non neoplastic, 39% were benign and 15% were malignant. The commonest benign neoplasm was giant cell tumour (GCT) (11 cases). Younger patients were more likely to have a benign neoplasm. Lesions in patients less than 40 years of age included giant cell tumour, chondroblastoma, aneurysmal bone cyst (ABC), osteomyelitis, osteoid osteoma and solitary bone cyst. In patients older than 40 years, the following were common lesions: intra-osseous gout, metastasis and intra-osseous ganglion. Expansion of the patella with thinning of cortex was seen more commonly in GCT and brown tumour in hyperparathyroidism. There was associated soft tissue extension in gout and malignant lesions. (orig.)

  4. Tumour and tumour-like lesions of the patella - a multicentre experience

    Energy Technology Data Exchange (ETDEWEB)

    Singh, J.; James, S.L.; Davies, A.M. [The Royal Orthopaedic Hospital, Department of Radiology, Birmingham (United Kingdom); Kroon, H.M. [Leiden University Medical Centre, Department of Radiology, C-2-S, P. O Box 9600, Leiden (Netherlands); Woertler, K. [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany); Anderson, S.E. [Knochentumor- Referenzzentrum der Schweizerischen Gesellschaft fuer Pathologie, Basel (Switzerland)

    2009-03-15

    Fifty-nine cases of lesions presenting in the patella were identified after review of the databases of four European bone tumour registries. Of the 59 cases, 46% were non neoplastic, 39% were benign and 15% were malignant. The commonest benign neoplasm was giant cell tumour (GCT) (11 cases). Younger patients were more likely to have a benign neoplasm. Lesions in patients less than 40 years of age included giant cell tumour, chondroblastoma, aneurysmal bone cyst (ABC), osteomyelitis, osteoid osteoma and solitary bone cyst. In patients older than 40 years, the following were common lesions: intra-osseous gout, metastasis and intra-osseous ganglion. Expansion of the patella with thinning of cortex was seen more commonly in GCT and brown tumour in hyperparathyroidism. There was associated soft tissue extension in gout and malignant lesions. (orig.)

  5. [Surgical Management of Peritoneal Surface Malignancy with Respect to Tumour Type, Tumour Stage and Individual Tumour Biology].

    Science.gov (United States)

    Beckert, S; Struller, F; Grischke, E-M; Glatzle, J; Zieker, D; Königsrainer, A; Königsrainer, I

    2016-08-01

    Peritoneal tumour dissemination is still considered as a terminal disease. For the last two decades, cytoreductive surgery (CRS) combined with intraoperative hyperthermic chemotherapy (HIPEC) has been popularised by Paul Sugarbaker almost doubling survival in selected patients compared with systemic chemotherapy alone. Nowadays, this particular treatment protocol is available in comprehensive cancer centres with reasonable mortality and morbidity. However, patient selection is still challenging. In general, CRS and HIPEC is indicated in primary peritoneal tumours such as mesothelioma and pseudomyxoma peritonei as well as in peritoneal metastases derived from gastrointestinal malignancies and ovarian cancers. Since systemic tumour spread is uncommon in patients with peritoneal metastases, peritoneal tumour dissemination was defined as localised disease within the "compartment abdomen". However, CRS and HIPEC are only beneficial as long as complete cytoreduction is achieved (CC-0 or CC-1). Histopathological parameters, the Sugarbaker peritoneal carcinomatosis index (PCI) and general condition of the patient have been established as patient selection criteria. In primary peritoneal cancers, individual tumour biology is the predominant criterium for patient selection as opposed to intraabdominal tumour load in peritoneal metastases derived from gastrointestinal cancers. In gastric cancer, CRS and HIPEC should be restricted to synchronous limited disease because of its biological aggressiveness. In patients with free floating cancer cells without macroscopic signs of peritoneal spread, however, CRS and HIPEC following preoperative "neoadjuvant" chemotherapy preserves chances for cure. So far, there is no general recommendation for CRS and HIPEC by clinical practice guidelines. In the recent S3 guideline for treatment of colorectal cancer, however, CRS and HIPEC have been included as possible treatment options. Georg Thieme Verlag KG Stuttgart · New York.

  6. Acoustic transmitter and receiver performance in freshwater and estuarine environments

    Science.gov (United States)

    We report on the performance of passive acoustic receivers intended to detect the passage of 281 acoustically tagged migratory salmonids in two Oregon coastal watersheds. We found that ambient acoustic noise can vary considerably with location, and that “sync” pulses thought to ...

  7. Diagnostic performance and impact on patient management of 68Ga-DOTA-TOC PET/CT for detecting osteomalacia-associated tumours.

    Science.gov (United States)

    Paquet, Marie; Gauthé, Mathieu; Zhang Yin, Jules; Nataf, Valérie; Bélissant, Ophélie; Orcel, Philippe; Roux, Christian; Talbot, Jean-Noël; Montravers, Françoise

    2018-03-12

    Oncogenic osteomalacia is an endocrine disorder induced by small benign tumours (TIO) producing excessive fibroblast growth factor-23 (FGF23). The only way of curing oncogenic osteomalacia is surgical resection of the culprit TIO, which is extremely difficult to detect using conventional imaging modalities due to its small size and variable location in the body. Since TIO frequently overexpress somatostatin receptors, a clinical utility of SPECT or PET with radiolabelled somatostatin analogues has been reported. Among them, 68 Ga-DOTA-TOC has recently been granted a marketing authorization, facilitating its routine application. We report here the results of the first series evaluating the diagnostic performance of 68 Ga-DOTA-TOC PET/CT in detecting TIO and its impact on patient management. 68 Ga-DOTA-TOC PET/CT and clinical and imaging data from 15 patients with clinical and biochemical signs of oncogenic osteomalacia were retrospectively reviewed. The 68 Ga-DOTA-TOC PET/CT findings were compared with the results of post-surgical pathology and clinical and biochemical follow-up. 68 Ga-DOTA-TOC PET/CT resulted in the detection of one focus suspicious for TIO in nine of 15 patients (60%), and a tumour was surgically removed in eight. Post-operative pathology confirmed a TIO in those eight patients whose symptoms diminished promptly and biochemical anomalies resolved. 68 Ga-DOTA-TOC PET/CT sensitivity, specificity and accuracy were 73%, 67% and 71%, respectively. 68 Ga-DOTA-TOC PET/CT findings affected patient management in 67% of cases. In particular, 68 Ga-DOTA-TOC PET/CT was able to detect the TIO with a negative or a false-positive result of a previous 111 In-pentetreotide SPECT/CT in 5/8 patients (63%) or a previous FDG PET/CT in 7/11 patients (64%). No close relationship was found between the positivity of 68 Ga-DOTA-TOC PET/CT and the serum level of a biochemical marker. However, a true-positive result of 68 Ga-DOTA-TOC PET/CT was obtained in only one patient

  8. Acoustic--nuclear permeability logging system

    International Nuclear Information System (INIS)

    Dowling, D.J.; Arnold, D.M.

    1978-01-01

    A down hole logging tool featuring a neutron generator, an acoustic disturbance generator, and a radiation detection system is described. An array of acoustic magnetostriction transducers is arranged about the target of a neutron accelerator. Two gamma ray sensors are separated from the accelerator target by shielding. According to the method of the invention, the underground fluid at the level of a formation is bombarded by neutrons which react with oxygen in the fluid to produce unstable nitrogen 16 particles according to the reaction 16 O(n,p) 16 N. Acoustic pulses are communicated to the fluid, and are incident on the boundary of the borehole at the formation. The resulting net flow of fluid across the boundary is determined from radiation detection measurements of the decaying 16 N particles in the fluid. A measure of the permeability of the formation is obtained from the determination of net fluid flow across the boundary

  9. Acoustic Localization with Infrasonic Signals

    Science.gov (United States)

    Threatt, Arnesha; Elbing, Brian

    2015-11-01

    Numerous geophysical and anthropogenic events emit infrasonic frequencies (<20 Hz), including volcanoes, hurricanes, wind turbines and tornadoes. These sounds, which cannot be heard by the human ear, can be detected from large distances (in excess of 100 miles) due to low frequency acoustic signals having a very low decay rate in the atmosphere. Thus infrasound could be used for long-range, passive monitoring and detection of these events. An array of microphones separated by known distances can be used to locate a given source, which is known as acoustic localization. However, acoustic localization with infrasound is particularly challenging due to contamination from other signals, sensitivity to wind noise and producing a trusted source for system development. The objective of the current work is to create an infrasonic source using a propane torch wand or a subwoofer and locate the source using multiple infrasonic microphones. This presentation will present preliminary results from various microphone configurations used to locate the source.

  10. Vaginal haemangioendothelioma: an unusual tumour.

    LENUS (Irish Health Repository)

    Mohan, H

    2012-02-01

    Vaginal tumours are uncommon and this is a particularly rare case of a vaginal haemangioendothelioma in a 38-year-old woman. Initial presentation consisted of symptoms similar to uterovaginal prolapse with "something coming down". Examination under anaesthesia demonstrated a necrotic anterior vaginal wall tumour. Histology of the lesion revealed a haemangioendothelioma which had some features of haemangiopericytoma. While the natural history of vaginal haemangioendothelioma is uncertain, as a group, they have a propensity for local recurrence. To our knowledge this is the third reported case of a vaginal haemangioendothelioma. Management of this tumour is challenging given the paucity of literature on this tumour. There is a need to add rare tumours to our "knowledge bank" to guide management of these unusual tumours.

  11. of brain tumours

    African Journals Online (AJOL)

    outline of the important clinical issues related to brain tumours and psychiatry. ... Left-sided, frontal tumours also seem to be associated with higher rates of depression, while those in the frontal lobe of the right .... Oxford: Blackwell Science,.

  12. Radioimmunoscintigraphy with monoclonal antibody Technetium-99m-Anti-EGF-Receptor (R3-MAB) for the detection of head and neck tumours, metastasis and recurrence. Final report for the period 15 April 1995 - 15 April 1997

    International Nuclear Information System (INIS)

    Oliva Gonzalez, J.P.

    1998-03-01

    A clinical study was carried out to determine the sensitivity of radioimmunoscintigraphy (RIS) using indigenously produced mouse monoclonal antibody (MAB) against epidermal growth factor receptor in the detection of primary, recurrent and metastatic malignant epithelial tumours of the head and neck region in 13 patients. The MAB was labelled with 99m Tc and imaging was carried out using gamma camera and SPECT. The results were correlated with histopathological findings. RIS gave a sensitivity of 76.9%. This study showed that the indigenously produced MAB can be used for the detection of malignant epithelial tumours in the head and neck region but the MAB will be further characterized to improve its sensitivity in the detection of the neoplasia. (author)

  13. Acoustical monitoring of diesel engines in reverberant environment

    International Nuclear Information System (INIS)

    Mein, M.

    1995-10-01

    The feed-back knowledge of emergency diesel generators in nuclear power plants shows that some malfunctions, mainly affecting fuel-injection or distribution system of the engine can be heard and detected by experienced maintenance agents. This study consists in the feasibility,v of acoustical monitoring of those diesel engines, taking into account the reverberant environment of the machine. The operating cycle of the diesel is composed of transient events (injection, combustion, valve closure...) which generate highly non stationary acoustical signals. The detection of a malfunction appearing on such transients requires the use of adapted signal processing techniques. Visual analysis of the phenomena is first proceeded using time-frequency and time-scale representations. The second step will be parametric modeling of acoustical signatures for the extraction of characteristic parameters, in order to characterize the fault and to use an automatic classification system. The lest part of the study will concern the evaluation of the robustness of the detection methods in regard to acoustical reverberation. (author). 10 refs., 6 figs

  14. PVT Degradation Studies: Acoustic Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Gerges [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smith, Philip J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-01

    Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. This document reports on a study of acoustic techniques to determine whether they can provide a diagnostic for the fogging of PVT. Different ultrasound techniques were employed for detecting the level of internal fogging in PVT, including wave velocity measurements, attenuation, nonlinear acoustics, and acoustic microscopy. The results indicate that there are linear relations between the wave velocity and wave attenuation with the level of internal fogging. The effects of fogging on ultrasound wave attenuation is further verified by acoustic microscopy imaging, where regions with fog in the specimen demonstration higher levels of attenuation compared to clear regions. Results from the nonlinear ultrasound measurements were inconclusive due to high sensitivities to transducer coupling and fixture variabilities.

  15. Evidence-based cross validation for acoustic power transmission for a novel treatment system.

    Science.gov (United States)

    Mihcin, Senay; Strehlow, Jan; Demedts, Daniel; Schwenke, Michael; Levy, Yoav; Melzer, Andreas

    2017-06-01

    The novel Trans-Fusimo Treatment System (TTS) is designed to control Magnetic Resonance guided Focused Ultrasound (MRgFUS) therapy to ablate liver tumours under respiratory motion. It is crucial to deliver the acoustic power within tolerance limits for effective liver tumour treatment via MRgFUS. Before application in a clinical setting, evidence of reproducibility and reliability is a must for safe practice. The TTS software delivers the acoustic power via ExAblate-2100 Conformal Bone System (CBS) transducer. A built-in quality assurance application was developed to measure the force values, using a novel protocol to measure the efficiency for the electrical power values of 100 and 150W for 6s of sonication. This procedure was repeated 30 times by two independent users against the clinically approved ExAblate-2100 CBS for cross-validation. Both systems proved to deliver the power within the accepted efficiency levels (70-90%). Two sample t-tests were used to assess the differences in force values between the ExAblate-2100 CBS and the TTS (p > 0.05). Bland-Altman plots were used to demonstrate the limits of agreement between the two systems falling within the 10% limits of agreement. Two sample t-tests indicated that TTS does not have user dependency (p > 0.05). The TTS software proved to deliver the acoustic power without exceeding the safety levels. Results provide evidence as a part of ISO13485 regulations for CE marking purposes. The developed methodology could be utilised as a part of quality assurance system in clinical settings; when the TTS is used in clinical practice.

  16. Synthetic Aperture Acoustic Imaging for Roadside Detection of Solid Objects

    Science.gov (United States)

    2014-11-20

    Testing I I I I Cinderblock Foam block Isometric and translucent view of the weighted foam block . .-.-; Weighted foam block Figure 2.3... concrete block (CB, Fig. 2.4). Conven- tional methods for identifying targets in a radar or acoustic imaging system (also known as Automatic Target...and curb, or than the grass-covered hill beyond the sidewalk. However, there is a strong acoustic return from a seam in the sidewalk concrete that runs

  17. Acoustic Leak Detection Requirements for a SFR Steam Generator Protection

    International Nuclear Information System (INIS)

    Kim, Tae-Joon; Jeong, Ji-Young; Oeh, Jae-Hyuk; Kim, Jong-Man; Kim, Byung-Ho; Yughay, Valery S.

    2008-01-01

    A large volume of fast reactor research has been executed in Russia, Japan, France, India and the United Kingdom. At present, an unique fast reactor named BN- 600 is operating in Russia. Also, the operation of research reactors such as Phenix (France), JOYO (Japan), BOR-60 (Russia) and FBTR (India) proceeds. The last project to be completed was the reactor Monju (Japan) which is now stopped. In addition activities for the development of fast reactors are being conducted in China, India, and South Korea. Fast reactors are a choice for the subsequent nuclear power generation in Korea, and their increased safety is one of the basic requirements. The basis for a tightening of the requirements on safety is the emergencies in NPPs in Russia, USA, France, Japan and other countries. These emergencies testify that the existing monitoring systems do not fully provide a well-timed detection of the distresses arising in a NPP, because of a poor sensitivity and response, thus the necessity for a better diagnostic system is obvious. In accordance with the USA GNEP initiative in Obninsk, Russia, 2007 the main efforts should be directed toward a sodium-water steam generator safety increase due to improvement of the hydrogen monitoring system and the acoustic leak detection system

  18. Management of parapharyngeal space tumours

    International Nuclear Information System (INIS)

    Ahmad, F.; Waqar-Uddin; Khan, M.S.; Khawar, A.; Bangush, W.; Aslam, J.

    2006-01-01

    Objective: To determine the role of clinical features, fine needle aspiration cytology (FNAC) and computed tomography (CT) scan in diagnosing Para pharyngeal space (PPS) tumours and treatment options. Design: A descriptive study. Place and Duration of Study: From July 2000 to July 2002 at Pakistan Institute of Medical Sciences, Islamabad. Patients and Methods: Patients diagnosed as having PPS tumours were studied. The medical record of patients was reviewed for their age, gender, clinical features, investigations (FNAC and CT scan) and treatment. The mean age, percentage of different clinical features and the sensitivity and specificity of FNAC was determined. Results: The mean age of patients presenting with PPS tumours was 33.6 years. The most common clinical features were neck mass (93%) and bulge in lateral pharyngeal wall (80%). The CT scan showed exact location and extent of tumour in 11 out of 15 cases. The sensitivity and specificity of FNAC was 70% and 85% respectively. The most common tumours were neurogenic tumours and salivary gland tumours. Surgery was performed in all except 2 patients with lymphoma in whom radiation and chemotherapy was recommended. Conclusion: This study indicates that PPS tumours are usually benign neurosurgeon and salivary gland tumours presenting with neck mass and bulge in or oropharynx. FNAC and CT scan are important in diagnostic work up and treatment planning. Surgery has the best results in most cases. (author)

  19. NW-MILO Acoustic Data Collection

    Energy Technology Data Exchange (ETDEWEB)

    Matzner, Shari; Myers, Joshua R.; Maxwell, Adam R.; Jones, Mark E.

    2010-02-17

    There is an enduring requirement to improve our ability to detect potential threats and discriminate these from the legitimate commercial and recreational activity ongoing in the nearshore/littoral portion of the maritime domain. The Northwest Maritime Information and Littoral Operations (NW-MILO) Program at PNNL’s Coastal Security Institute in Sequim, Washington is establishing a methodology to detect and classify these threats - in part through developing a better understanding of acoustic signatures in a near-shore environment. The purpose of the acoustic data collection described here is to investigate the acoustic signatures of small vessels. The data is being recorded continuously, 24 hours a day, along with radar track data and imagery. The recording began in August 2008, and to date the data contains tens of thousands of signals from small vessels recorded in a variety of environmental conditions. The quantity and variety of this data collection, with the supporting imagery and radar track data, makes it particularly useful for the development of robust acoustic signature models and advanced algorithms for signal classification and information extraction. The underwater acoustic sensing system is part of a multi-modal sensing system that is operating near the mouth of Sequim Bay. Sequim Bay opens onto the Straight of Juan de Fuca, which contains part of the border between the U.S. and Canada. Table 1 lists the specific components used for the NW-MILO system. The acoustic sensor is a hydrophone permanently deployed at a mean depth of about 3 meters. In addition to a hydrophone, the other sensors in the system are a marine radar, an electro-optical (EO) camera and an infra-red (IR) camera. The radar is integrated with a vessel tracking system (VTS) that provides position, speed and heading information. The data from all the sensors is recorded and saved to a central server. The data has been validated in terms of its usability for characterizing the

  20. [Neonatal tumours and congenital malformations].

    Science.gov (United States)

    Berbel Tornero, O; Ortega García, J A; Ferrís i Tortajada, J; García Castell, J; Donat i Colomer, J; Soldin, O P; Fuster Soler, J L

    2008-06-01

    The association between pediatric cancer and congenital abnormalities is well known but, there is no exclusive data on the neonatal period and the underlying etiopathogenic mechanisms are unknown. First, to analyze the frequency of neonatal tumours associated with congenital abnormalities; and second, to comment on the likely etiopathogenic hypotheses of a relationship between neonatal tumours and congenital abnormalities. Historical series of neonatal tumours from La Fe University Children's Hospital in Valencia (Spain), from January 1990 to December 1999. Histological varieties of neonatal tumours and associated congenital abnormalities were described. A systematic review of the last 25 years was carried out using Medline, Cancerlit, Index Citation Science and Embase. The search profile used was the combination of "neonatal/congenital-tumors/cancer/neoplasms" and "congenital malformations/birth defects". 72 neonatal tumours were identified (2.8% of all pediatric cancers diagnosed in our hospital) and in 15 cases (20.8%) there was some associated malformation, disease or syndrome. The association between congenital abnormalities and neonatal tumours were: a) angiomas in three patients: two patients with congenital heart disease with a choanal stenosis, laryngomalacia; b) neuroblastomas in two patients: horseshoe kidney with vertebral anomalies and other with congenital heart disease; c) teratomas in two patients: one with cleft palate with vertebral anomalies and other with metatarsal varus; d) one tumour of the central nervous system with Bochdaleck hernia; e) heart tumours in four patients with tuberous sclerosis; f) acute leukaemia in one patient with Down syndrome and congenital heart disease; g) kidney tumour in one case with triventricular hydrocephaly, and h) adrenocortical tumour: hemihypertrophy. The publications included the tumours diagnosed in different pediatric periods and without unified criteria to classify the congenital abnormalities. Little data

  1. Combined Opto-Acoustical sensor modules for KM3NeT

    International Nuclear Information System (INIS)

    Enzenhöfer, A.

    2013-01-01

    KM3NeT is a future multi-cubic-kilometre water Cherenkov neutrino telescope currently entering a first construction phase. It will be located in the Mediterranean Sea and comprise about 600 vertical structures called detection units. Each of these detection units has a length of several hundred metres and is anchored to the sea bed on one side and held taut by a buoy on the other side. The detection units are thus subject to permanent movement due to sea currents. Modules holding photosensors and additional equipment are equally distributed along the detection units. The relative positions of the photosensors has to be known with an uncertainty below 20 cm in order to achieve the necessary precision for neutrino astronomy. These positions can be determined with an acoustic positioning system: dedicated acoustic emitters located at known positions and acoustic receivers along each detection unit. This article describes the approach to combine an acoustic receiver with the photosensors inside one detection module using a common power supply and data readout. The advantage of this approach lies in a reduction of underwater connectors and module configurations as well as in the compactification of the detection units integrating the auxiliary devices necessary for their successful operation.

  2. Ion acoustic waves in the solar wind

    International Nuclear Information System (INIS)

    Gurnett, D.A.; Frank, L.A.

    1978-01-01

    Plasma wave measurements on the Helios I and 2 spacecraft have revealed the occurrence of electric field turbulence in the solar wind at frequencies between the electron and ion plasma frequencies. Wavelength measurements with the Imp 6 spacecraft now provide strong evidence that these waves are short-wavelength ion acoustic waves which are Doppler-shifted upward in frequency by the motion of the solar wind. Comparison of the Helios results with measurements from the earth-orbiting Imp 6 and 8 spacecraft shows that the ion acoustic turbulence detected in interplanetary space has characteristics essentially identical to those of bursts of electrostatic turbulence generated by protons streaming into the solar wind from the earth's bow shock. In a few cases, enhanced ion acoustic wave intensities have been observed in direct association with abrupt increases in the anisotropy of the solar wind electron distribution. This relationship strongly suggests that the ion acoustic waves detected by Helios far from the earth are produced by an electron heat flux instability, as was suggested by Forslund. Possible related mechanisms which could explain the generation of ion acoustic waves by protons streaming into the solar wind from the earth's bow shock are also considered

  3. Comparison of metastatic disease after local tumour treatment with radiotherapy or surgery in various tumour models

    International Nuclear Information System (INIS)

    Ruiter, J. de; Cramer, S.J.; Lelieveld, P.; Putten, L.M. van

    1982-01-01

    Spontaneous metastases in lymph nodes and/or the lung were obtained after tumour cell inoculation of four mouse tumours and one rat tumour into the foot-pads of syngeneic animals or their F 1 hybrids. Following local radiotherapy with doses of 45-80 Gy, significantly more mice died with metastases than following local amputation of the tumour-bearing foot when the 2661 carcinoma was involved. No significant difference was observed after these treatments for the other tumours. The enhancement of metastatic growth after local radiotherapy in the 2661 carcinoma seems not to be due to incomplete killing of tumour cells in the foot. The presence of irradiated normal structures and tumour tissue after radiotherapy promoted the outgrowth of 2661 carcinoma cells which were outside the radiation field at the time of treatment. Evidently, even under similar experimental conditions, radiotherapy may enhance the growth of metastases from some tumours and not from others. (author)

  4. Id1 suppresses anti-tumour immune responses and promotes tumour progression by impairing myeloid cell maturation.

    Science.gov (United States)

    Papaspyridonos, Marianna; Matei, Irina; Huang, Yujie; do Rosario Andre, Maria; Brazier-Mitouart, Helene; Waite, Janelle C; Chan, April S; Kalter, Julie; Ramos, Ilyssa; Wu, Qi; Williams, Caitlin; Wolchok, Jedd D; Chapman, Paul B; Peinado, Hector; Anandasabapathy, Niroshana; Ocean, Allyson J; Kaplan, Rosandra N; Greenfield, Jeffrey P; Bromberg, Jacqueline; Skokos, Dimitris; Lyden, David

    2015-04-29

    A central mechanism of tumour progression and metastasis involves the generation of an immunosuppressive 'macroenvironment' mediated in part through tumour-secreted factors. Here we demonstrate that upregulation of the Inhibitor of Differentiation 1 (Id1), in response to tumour-derived factors, such as TGFβ, is responsible for the switch from dendritic cell (DC) differentiation to myeloid-derived suppressor cell expansion during tumour progression. Genetic inactivation of Id1 largely corrects the myeloid imbalance, whereas Id1 overexpression in the absence of tumour-derived factors re-creates it. Id1 overexpression leads to systemic immunosuppression by downregulation of key molecules involved in DC differentiation and suppression of CD8 T-cell proliferation, thus promoting primary tumour growth and metastatic progression. Furthermore, advanced melanoma patients have increased plasma TGFβ levels and express higher levels of ID1 in myeloid peripheral blood cells. This study reveals a critical role for Id1 in suppressing the anti-tumour immune response during tumour progression and metastasis.

  5. Diagnostic utility of Wilms′ tumour-1 protein (WT-1 immunostaining in paediatric renal tumours

    Directory of Open Access Journals (Sweden)

    Surbhi Goyal

    2016-01-01

    Interpretation & conclusions: WT1 helps to differentiate Wilms′ tumour from other paediatric renal tumours. It may help in differentiating the two subgroups of Wilms′ tumour which have distinct molecular pathogenesis and biological behaviour, however, further prospective studies are required for validation of this hypothesis.

  6. Acoustic damage detection in laser-cut CFRP composite materials

    Science.gov (United States)

    Nishino, Michiteru; Harada, Yoshihisa; Suzuki, Takayuki; Niino, Hiroyuki

    2012-03-01

    Carbon fiber reinforced plastics (CFRP) composite material, which is expected to reduce the weight of automotive, airplane and etc., was cut by laser irradiation with a pulsed-CO2 laser (TRUMPF TFL5000; P=800W, 20kHz, τ=8μs, λ=10.6μm, V=1m/min) and single-mode fiber lasers (IPG YLR-300-SM; P=300W, λ=1.07μm, V=1m/min)(IPG YLR- 2000-SM; P=2kW, λ=1.07μm, V=7m/min). To detect thermal damage at the laser cutting of CFRP materials consisting of thermoset resin matrix and PAN or PITCH-based carbon fiber, the cut quality was observed by X-ray CT. The effect of laser cutting process on the mechanical strength for CFRP tested at the tensile test. Acoustic emission (AE) monitoring, high-speed camera and scanning electron microscopy were used for the failure process analysis. AE signals and fractographic features characteristic of each laser-cut CFRP were identified.

  7. Evaluation of forced-convection nucleate boiling detection by acoustic emission

    International Nuclear Information System (INIS)

    Wells, R.P.; Paterson, J.A.

    1981-10-01

    Acoustic Emission techniques are being investigated for use as protection systems in neutral beam accelerators and water cooled beam dumps. For this purpose, the characteristics of the boiling curve for forced-convection surface boiling have been compared to the Acoustic Emission (AE) produced. Results indicate that AE, in the form of count-rate, is a sensitive indicator of nucleate boiling incipience and is relatively insensitive to flow velocity in the 0 to 12 m/s range

  8. Allograft in bone tumour surgery

    International Nuclear Information System (INIS)

    Sengupta, S.

    1999-01-01

    In the last twenty years, there has been a vast improvement in the prognosis of primary malignant tumours of bone. This is due to many factors including early detection, staging and classification of tumours as a result of better staining and imaging techniques, better surgical technology, e.g. endoprosthesis and most importantly adjuvant treatment with cytotoxic drugs. As a result of long term survival, amputation of limb has more or less been replaced by limb salvage surgery. This procedure consists of two parts. Primary objective is of course complete removal of the tumour by adequate soft tissue cover and secondarily by reconstruction of the locomotor system, If possible with retention of the function of the limb. These procedures include endo-prosthetic replacement or arthroplasty and arthrodesis using autologus grafts, allograft or combination. With the development of bone banks and assured safety of preserved bones, reconstructive limb salvage surgery using massive allograft is gradually replacing prosthetic implants. The advantages include replacement of articular surfaces, incorporation of the graft to the host bone, attachment of bone tissue and increased probably permanent survival. Allograft can be used for intercalary replacement, osteo-articular arthroplasty arthrodesis or filling large cavities. Inherent complication of massive allograft are disease transmission, infection, delayed and non-union, pathological fractures, mechanical failure and joint destruction. Several limb salvage procedures using allografts have been carried out in our institution with one failure due to infection. Paucity of available allograft has restricted more such procedures to be carried out

  9. Industrial installation surveillance acoustic device

    International Nuclear Information System (INIS)

    Marini, Jean; Audenard, Bernard.

    1981-01-01

    The purpose of this invention is the detection of possible impacts of bodies migrating inside the installation, using acoustic sensors of the waves emitted at the time of impact of the migrating bodies. This device makes it possible to take into account only those acoustic signals relating to the impacts of bodies migrating in the area under surveillance, to the exclusion of any other acoustic or electric perturbing phenomenon. The invention has a preferential use in the case of a linear shape installation in which a fluid flows at high rate, such as a section of the primary system of a pressurized water nuclear reactor [fr

  10. Calibration of acoustic sensors in ice using the reciprocity method

    Energy Technology Data Exchange (ETDEWEB)

    Meures, Thomas; Bissok, Martin; Laihem, Karim; Paul, Larissa; Wiebusch, Christopher; Zierke, Simon [III. Physikalisches Institut, RWTH Aachen (Germany); Semburg, Benjamin [Bergische Universitaet Wuppertal (Germany). Fachbereich C

    2010-07-01

    Within the IceCube experiment at the South Pole an R and D program investigates new ways of ultra high energy neutrino detection. In particular when aiming for detector volumes of the order of 100 km{sup 3} acoustic or radio detectors are promising approaches. The acoustic detection method relies on the thermo-acoustic effect occurring when high energetic particles interact and deposit heat within a detection medium. This effect is investigated in the Aachen Acoustic Laboratory (AAL). The high energy particle interaction is simulated by a powerful pulsed Nd:YAG LASER shooting into a 3m{sup 3} tank of clear ice (or water). Eighteen acoustic sensors are situated on three rings in different depths and record the generated signals. These sensors serve as reference for later measurements of other devices. The reciprocity method, used for the absolute calibration of these sensors, is independent of an absolutely calibrated reference. This method and its application to the calibration of the AAL sensors are presented and first results are shown.

  11. [Clinical and radiological evolution of a group of untreated acoustic neuromas].

    Science.gov (United States)

    Escorihuela-García, Vicente; Llópez-Carratalá, Ignacio; Orts-Alborch, Miguel; Marco-Algarra, Jaime

    2014-01-01

    The acoustic neuroma is a benign tumour that originates in the vestibular branch of the eighth cranial nerve. The main treatment is surgery, but many authors suggest that with elderly patients or in small neuromas we can opt for watchful waiting. This was a retrospective study from 2007 to 2013 that included 27 patients diagnosed of acoustic neuroma that had not been treated due to the size of the tumour, age and comorbidities, or by patient choice. We evaluated overall condition, hearing thresholds, degree of canal paresis and central disorders. After 6 years of follow up, clinical manifestations of 18 patients remained unchanged, 5 patients underwent hearing loss and developed tinnitus, 2 cases had more intense tinnitus and 2 cases had dizziness. The radiological controls by magnetic resonance imaging showed that the initial maximum diameters (5-16mm) increased by 1.7mm on average, with annual growth rates below 0.5mm. In selected cases, such as for small neuromas and in elderly patients, the conservative option of close monitoring with magnetic resonance imaging is an important alternative given that, in our cases, clinical features and radiological image did not suffer major changes. If there were any such changes, therapeutic options could be proposed. Copyright © 2013 Elsevier España, S.L. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  12. Pick 'n' mix: neuropatholgical detection of peri-tumour taupathy.

    LENUS (Irish Health Repository)

    Lonergan, Roisin

    2013-11-01

    Radiotherapy is used to treat recurrent oligodendrogliomas, WHO grade 2 tumours. Potential morbitities include steroid-responsive radiation necrosis and radiation leucoencephalopathy, characterised pathologically by reactive astrogliosis, focal necrosis, demyelination, axonal loss, and clinically by progressive subcortical deficits (ataxia, amnesia, incontinence, cognitive decline), with relative sparing of cortical function. Although subcortical features may overlap with neurodegenerative conditions (eg frontotemporal dementia), focal cortical atrophy of FTD causes loss of language function in addition to memory, and specific histopathological features characterise FTD subtypes (eg Pick disease). Association between mitotic disease and tauopathy has not been reported widely, but co-existence is possible. Diagnostic accuracy may guide management.

  13. Radiodiagnosis of tumours of gastrointestinal tract

    International Nuclear Information System (INIS)

    Sokolov, Yu.N.; Antonovich, V.B.

    1981-01-01

    Systematic description of X-ray picture of tumours of gastrointestinal tract organs is given. The possibilities of contemporary methods of X-ray examination in their revealing are shown. Clinical and X-ray trend of tumour diagnosis is underlined. The basic and accessory symptoms are analyzed from which X-ray semiotics of tumours is turned out. The expressiveness of X-ray symptoms is shown in relation to morphological forms and localization of the tumours. Much attention is given to radiodiagnosis of early tumours of stomach. Differential diagnosis of tumours with non-tumoural diseases is given. X-ray semiotics of lesions of gastrointestinal tract organs in malignant diseases of blood system is presented [ru

  14. Giant cell tumour in the foot of a skeletally immature girl: a case report.

    LENUS (Irish Health Repository)

    Baker, Joseph F

    2009-08-01

    We present a case of delayed diagnosis of a benign giant cell tumour (GCT) of the third metatarsal in a skeletally immature girl. The patient underwent en bloc excision of the tumour. The tumour had replaced the third metatarsal and had infiltrated the surrounding soft tissue and the second and fourth metatarsal bases. Deep, lateral and medial margins were all involved. A high index of suspicion is needed when evaluating any tumours of the foot, because the compact structure of the foot may delay diagnosis. Early detection is important for avoiding amputation, as the hindfoot and midfoot are classified as one compartment and radical resection is impossible to achieve. Tumours grow faster in the foot than in other bones. GCT in this location and age-group are rare and should be considered in the differential diagnosis of a destructive bony lesion in skeletally immature patients.

  15. New evidence for the origin of intracranial germ cell tumours from primordial germ cells

    DEFF Research Database (Denmark)

    Hoei-Hansen, C E; Sehested, A; Juhler, M

    2006-01-01

    that it is not required for the initiation of malignant germ cell transformation. The expression of genes associated with embryonic stem cell pluripotency in CNS germ cell tumours strongly suggests that these tumours are derived from cells that retain, at least partially, an embryonic stem cell-like phenotype, which...... germ cell tumours and analysed expression of a wide panel of stem cell-related proteins (C-KIT, OCT-3/4 (POU5F1), AP-2gamma (TFAP2C), and NANOG) and developmentally regulated germ cell-specific proteins (including MAGE-A4, NY-ESO-1, and TSPY). Expression at the protein level was analysed in 21 children...... and young adults with intracranial germinomas and non-germinomas, contributing to a careful description of these unusual tumours and adding to the understanding of pathogenesis. Stem cell related proteins were highly expressed in intracranial germ cell tumours, and many similarities were detected...

  16. Acoustic cloaking and transformation acoustics

    International Nuclear Information System (INIS)

    Chen Huanyang; Chan, C T

    2010-01-01

    In this review, we give a brief introduction to the application of the new technique of transformation acoustics, which draws on a correspondence between coordinate transformation and material properties. The technique is formulated for both acoustic waves and linear liquid surface waves. Some interesting conceptual devices can be designed for manipulating acoustic waves. For example, we can design acoustic cloaks that make an object invisible to acoustic waves, and the cloak can either encompass or lie outside the object to be concealed. Transformation acoustics, as an analog of transformation optics, can go beyond invisibility cloaking. As an illustration for manipulating linear liquid surface waves, we show that a liquid wave rotator can be designed and fabricated to rotate the wave front. The acoustic transformation media require acoustic materials which are anisotropic and inhomogeneous. Such materials are difficult to find in nature. However, composite materials with embedded sub-wavelength resonators can in principle be made and such 'acoustic metamaterials' can exhibit nearly arbitrary values of effective density and modulus tensors to satisfy the demanding material requirements in transformation acoustics. We introduce resonant sonic materials and Helmholtz resonators as examples of acoustic metamaterials that exhibit resonant behaviour in effective density and effective modulus. (topical review)

  17. Malignant thyroid tumours

    International Nuclear Information System (INIS)

    Boerner, W.; Reiners, C.

    1987-01-01

    The subjects dealt with at the symposium cover all topical aspects of pathology, epidemiology, diagnosis, therapy, and aftercare of the malignant thyroid tumours. A survey of the histological classification of the thyroid tumours and a review of the latest findings concerning the radiocarcinogenesis are followed by a detailed discussion of the most significant tumours. There are also papers dealing with controversial aspects of the histological classification, the value of diagnostic methods, radicality of the therapy, or after care. For five conference papers, separate records are available in the database. (orig./ECB) With 59 figs.; 57 tabs [de

  18. FDG PET imaging of Ela1-myc mice reveals major biological differences between pancreatic acinar and ductal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Abasolo, Ibane [Institut Municipal d' Investigacio Medica-Hospital del Mar, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Universitat Pompeu Fabra, Parc de Recerca Biomedica de Barcelona, Departament de Ciencies Experimentals i de la Salut, Barcelona (Spain); Institut d' Alta Tecnologia - CRC, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Pujal, Judit; Navarro, Pilar [Institut Municipal d' Investigacio Medica-Hospital del Mar, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Rabanal, Rosa M.; Serafin, Anna [Universitat Autonoma de Barcelona, Departament de Medicina i Cirurgia Animals, Barcelona (Spain); Millan, Olga [Institut d' Alta Tecnologia - CRC, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Real, Francisco X. [Institut Municipal d' Investigacio Medica-Hospital del Mar, Parc de Recerca Biomedica de Barcelona, Barcelona (Spain); Universitat Pompeu Fabra, Parc de Recerca Biomedica de Barcelona, Departament de Ciencies Experimentals i de la Salut, Barcelona (Spain); Programa de Patologia Molecular, Centro Nacional de Investigaciones Oncologicas, Madrid (Spain)

    2009-07-15

    The aim was to evaluate FDG PET imaging in Ela1-myc mice, a pancreatic cancer model resulting in the development of tumours with either acinar or mixed acinar-ductal phenotype. Transversal and longitudinal FDG PET studies were conducted; selected tissue samples were subjected to autoradiography and ex vivo organ counting. Glucose transporter and hexokinase mRNA expression was analysed by quantitative reverse transcription polymerase chain reaction (RT-PCR); Glut2 expression was analysed by immunohistochemistry. Transversal studies showed that mixed acinar-ductal tumours could be identified by FDG PET several weeks before they could be detected by hand palpation. Longitudinal studies revealed that ductal - but not acinar - tumours could be detected by FDG PET. Autoradiographic analysis confirmed that tumour areas with ductal differentiation incorporated more FDG than areas displaying acinar differentiation. Ex vivo radioactivity measurements showed that tumours of solely acinar phenotype incorporated more FDG than pancreata of non-transgenic littermates despite the fact that they did not yield positive PET images. To gain insight into the biological basis of the differential FDG uptake, glucose transporter and hexokinase transcript expression was studied in microdissected tumour areas enriched for acinar or ductal cells and validated using cell-specific markers. Glut2 and hexokinase I and II mRNA levels were up to 20-fold higher in ductal than in acinar tumours. Besides, Glut2 protein overexpression was found in ductal neoplastic cells but not in the surrounding stroma. In Ela1-myc mice, ductal tumours incorporate significantly more FDG than acinar tumours. This difference likely results from differential expression of Glut2 and hexokinases. These findings reveal previously unreported biological differences between acinar and ductal pancreatic tumours. (orig.)

  19. FDG PET imaging of Ela1-myc mice reveals major biological differences between pancreatic acinar and ductal tumours

    International Nuclear Information System (INIS)

    Abasolo, Ibane; Pujal, Judit; Navarro, Pilar; Rabanal, Rosa M.; Serafin, Anna; Millan, Olga; Real, Francisco X.

    2009-01-01

    The aim was to evaluate FDG PET imaging in Ela1-myc mice, a pancreatic cancer model resulting in the development of tumours with either acinar or mixed acinar-ductal phenotype. Transversal and longitudinal FDG PET studies were conducted; selected tissue samples were subjected to autoradiography and ex vivo organ counting. Glucose transporter and hexokinase mRNA expression was analysed by quantitative reverse transcription polymerase chain reaction (RT-PCR); Glut2 expression was analysed by immunohistochemistry. Transversal studies showed that mixed acinar-ductal tumours could be identified by FDG PET several weeks before they could be detected by hand palpation. Longitudinal studies revealed that ductal - but not acinar - tumours could be detected by FDG PET. Autoradiographic analysis confirmed that tumour areas with ductal differentiation incorporated more FDG than areas displaying acinar differentiation. Ex vivo radioactivity measurements showed that tumours of solely acinar phenotype incorporated more FDG than pancreata of non-transgenic littermates despite the fact that they did not yield positive PET images. To gain insight into the biological basis of the differential FDG uptake, glucose transporter and hexokinase transcript expression was studied in microdissected tumour areas enriched for acinar or ductal cells and validated using cell-specific markers. Glut2 and hexokinase I and II mRNA levels were up to 20-fold higher in ductal than in acinar tumours. Besides, Glut2 protein overexpression was found in ductal neoplastic cells but not in the surrounding stroma. In Ela1-myc mice, ductal tumours incorporate significantly more FDG than acinar tumours. This difference likely results from differential expression of Glut2 and hexokinases. These findings reveal previously unreported biological differences between acinar and ductal pancreatic tumours. (orig.)

  20. An Evaluation of the Acoustic Signal processing Techniques for Sodium-Water Reaction Detection in KALIMER-600

    International Nuclear Information System (INIS)

    Hur, Seop; Seong, S. H.; Kim, T. J.; Kim, S. O.; Lee, M. K.

    2005-02-01

    KALIMER-600 is a pool type fast breeder reactor using liquid sodium as a coolant. Although it has the several advantages such as long-term fuel cycle and enhanced safety concepts, it is possible to leak the secondary side water/steam into sodium boundary. This event could make the plant abnormal condition. One of the major design issues in KALIMER-600 is, therefore, to develop the system which can early detect the sodium-water reaction to protect the sodium-water reaction event. After evaluating the various signal processing techniques for passive acoustic leak detection, we have proposed the early leak detection logics. the signal processing techniques for evaluation were the spectral estimation using the linear modeling, the estimation error of linear modeling, the system adaptation rate using an adaptive signal processing, and the background noise cancellation using adaptive and fixed filtering. As the analysis results regarding the stationary and the cross-correlation of leak signals and background noises, the two signal systems met a wide-dense stationary process and there was only the week cross correlation relationship between two signals. It is ,therefore, possible to use the linear/harmonic modeling of signal systems, and the leak signal in sensor outputs can be discriminated. As the results of the evaluation of the various spectral estimation methods, the spectral estimation method based on autoregressive modeling was more practical comparing with other methods in the sodium-water reaction detection. The passive acoustic leak detection logics were suggested based on above evaluations. the logics consist of 3 levels; transient identification, leak determination and leak symptom identification. The simulation results using sodium-water reaction signals showed that it was possible to determine the leak at above -3dB of SNR, while between -3 dB and -10 dB of SNR the logics determined the leak symptom identification. The detection sensitivity can be enhanced

  1. Targeted BCL2 inhibition effectively inhibits neuroblastoma tumour growth

    NARCIS (Netherlands)

    Lamers, Fieke; Schild, Linda; den Hartog, Ilona J. M.; Ebus, Marli E.; Westerhout, Ellen M.; Ora, Ingrid; Koster, Jan; Versteeg, Rogier; Caron, Huib N.; Molenaar, Jan J.

    2012-01-01

    Genomic aberrations of key regulators of the apoptotic pathway have hardly been identified in neuroblastoma. We detected high BCL2 mRNA and protein levels in the majority of neuroblastoma tumours by Affymetrix expression profiling and Tissue Micro Array analysis. This BCL2 mRNA expression is

  2. Acoustic Signature Monitoring and Management of Naval Platforms

    NARCIS (Netherlands)

    Basten, T.G.H.; Jong, C.A.F. de; Graafland, F.; Hof, J. van 't

    2015-01-01

    Acoustic signatures make naval platforms susceptible to detection by threat sensors. The variable operational conditions and lifespan of a platform cause variations in the acoustic signature. To deal with these variations, a real time signature monitoring capability is being developed, with advisory

  3. Teratoid Wilms tumour with chemotherapy resistance

    Directory of Open Access Journals (Sweden)

    Renuka Gahine

    2015-01-01

    Full Text Available We present a case of Teratoid Wilms tumour (a rare histologic variant in a 4 year old male who presented with an abdominal lump. Wilms Tumour with paracaval lymphadenopathy and tumour thrombi in right renal vein and inferior vena cava was made radiologically. FNAC report was suggestive of Wilms tumour and patient was subjected to 6 cycles of chemotherapy with not much reduction in size. Post nephrectomy histological diagnosis of Teratoid Wilms tumour was established. Resistance to chemotherapy and radiotherapy is thought to be due to presence of well differentiated histologic appearance. Teratoid Wilms tumour is usually not an aggressive neoplasm and prognosis is comparatively neoplasm and prognosis is comparatively good if the tumour is excised completely thus surgery being the best treatment.

  4. Developments in acoustic emission for application to nuclear reactor systems

    International Nuclear Information System (INIS)

    Bentley, P.G.

    1982-01-01

    Developments in acoustic emission are summarised as they relate to the principal applications to nuclear reactors, and light water reactor pressure vessels in particular. Improvement in the understanding of acoustic emission has come from materials tests and these confirm the problems in applying the technique for in-service or periodic proof test monitoring of growing fatique cracks. Applications in LMFBR have confirmed that acoustic emission can be applied in the nuclear environment and the detection of stress corrosion cracking in both BWR and LMFBR seems possible. Some information is included on the developing interest in applying the techniques of acoustic emission for leak detection during shop hydro and in-service monitoring. Acoustic emission is also being developed for weld fabrication monitoring and recently introduced pattern recognition techniques are having a significant impact in this application. (author)

  5. An Improved Azimuth Angle Estimation Method with a Single Acoustic Vector Sensor Based on an Active Sonar Detection System.

    Science.gov (United States)

    Zhao, Anbang; Ma, Lin; Ma, Xuefei; Hui, Juan

    2017-02-20

    In this paper, an improved azimuth angle estimation method with a single acoustic vector sensor (AVS) is proposed based on matched filtering theory. The proposed method is mainly applied in an active sonar detection system. According to the conventional passive method based on complex acoustic intensity measurement, the mathematical and physical model of this proposed method is described in detail. The computer simulation and lake experiments results indicate that this method can realize the azimuth angle estimation with high precision by using only a single AVS. Compared with the conventional method, the proposed method achieves better estimation performance. Moreover, the proposed method does not require complex operations in frequencydomain and achieves computational complexity reduction.

  6. An Improved Azimuth Angle Estimation Method with a Single Acoustic Vector Sensor Based on an Active Sonar Detection System

    Directory of Open Access Journals (Sweden)

    Anbang Zhao

    2017-02-01

    Full Text Available In this paper, an improved azimuth angle estimation method with a single acoustic vector sensor (AVS is proposed based on matched filtering theory. The proposed method is mainly applied in an active sonar detection system. According to the conventional passive method based on complex acoustic intensity measurement, the mathematical and physical model of this proposed method is described in detail. The computer simulation and lake experiments results indicate that this method can realize the azimuth angle estimation with high precision by using only a single AVS. Compared with the conventional method, the proposed method achieves better estimation performance. Moreover, the proposed method does not require complex operations in frequencydomain and achieves computational complexity reduction.

  7. Perceptual thresholds for detecting modifications applied to the acoustical properties of a violin.

    Science.gov (United States)

    Fritz, Claudia; Cross, Ian; Moore, Brian C J; Woodhouse, Jim

    2007-12-01

    This study is the first step in the psychoacoustic exploration of perceptual differences between the sounds of different violins. A method was used which enabled the same performance to be replayed on different "virtual violins," so that the relationships between acoustical characteristics of violins and perceived qualities could be explored. Recordings of real performances were made using a bridge-mounted force transducer, giving an accurate representation of the signal from the violin string. These were then played through filters corresponding to the admittance curves of different violins. Initially, limits of listener performance in detecting changes in acoustical characteristics were characterized. These consisted of shifts in frequency or increases in amplitude of single modes or frequency bands that have been proposed previously to be significant in the perception of violin sound quality. Thresholds were significantly lower for musically trained than for nontrained subjects but were not significantly affected by the violin used as a baseline. Thresholds for the musicians typically ranged from 3 to 6 dB for amplitude changes and 1.5%-20% for frequency changes. Interpretation of the results using excitation patterns showed that thresholds for the best subjects were quite well predicted by a multichannel model based on optimal processing.

  8. Acoustic emission technique for leak detection in an end shield of a pressurized heavy water reactor

    International Nuclear Information System (INIS)

    Kalyanasundaram, P.; Jayakumar, T.; Raj, B.

    1989-01-01

    This paper discusses the successful application of the Acoustic Emission Technique (AET) for detection and location of leak paths present on the inaccessible side of an end shield of a Pressurized Heavy Water Reactor (PHWR). The methodology was based on the fact that air and water leak AE signals have different characteristic features. Baseline data was generated from a sound end-shield of a PHWR for characterizing the background noise. A mock up end-shield system with saw cut leak paths was used to verify the validity of the methodology. It was found that air leak signals under pressurisation (as low as 3 psi) could be detected by frequency domain analysis. Signals due to air leaks from various locations of a defective end-shield were acquired and analysed. It was possible to detect and locate leak paths. Presence of detected leak paths were further confirmed by alternate test. (orig.)

  9. 51Cr-bleomycin in the diagnosis of tumours of the chest

    International Nuclear Information System (INIS)

    Brykalski, D.; Liniecki, J.; Dobek, J.; Pertynski, T.; Fajndt, S.; Studniarek, M.; Durski, K.; Mussur, M.; Akademia Medyczna, Lodz; Akademia Medyczna, Lodz; Osrodek Onkologiczny, Lodz

    1985-01-01

    51 Cr-bleomycin was used for the scintigraphic diagnosis of primary and secondary tumours of the thorax. The study was based on observations in 104 patients. The scintigraphy was performed using a gamma camera coupled to an on-line computer. Active lesions were scored using a semiquantitative scale of scores 0 to 5. Images were subdivided into 222 regions considered. In 72 of these, the presence of disease was diagnosed (64 malignant, 8 non-malignant) and 150 regions were classified as free from disease. At the decision threshold of score 2, over-all sensitivity and specificity of the scintigraphic detection of malignant tumours amounted to 97 and 79%, respectively. Inflammatory changes displaced some detectable accumulation of 51 Cr-bleomycin but scores attributed to these lesions did not exceed the value of 2. (orig.) [de

  10. Acoustic detection of a cavitation noise in the French breeder reactor Phenix

    International Nuclear Information System (INIS)

    Brunet, M.; Desprets, A.

    1981-06-01

    The French Phenix reactor is provided with an in-core multi-sensor acoustic surveillance system. But its efficiency with regard to early boiling detection is still to be proven. For lack of boiling events within the core, a cavitating dummy steel subassembly has been loaded into the reactor, as a simulation of boiling signal. Cavitation is controlled through a slow rise of the primary flow in various core conditions: isothermal situation and during a rise of power. Assuming that the signal to noise ratio is of the same order of magnitude for cavitation signals as for boiling ones, the response of several signal processing techniques is evaluated. Pulse connecting seems to be the most efficient conventional method while pattern recognition appears as a promising alternative solution

  11. Detection of Lipid-Rich Prostate Circulating Tumour Cells with Coherent Anti-Stokes Raman Scattering Microscopy

    International Nuclear Information System (INIS)

    Mitra, Ranjana; Chao, Olivia; Urasaki, Yasuyo; Goodman, Oscar B; Le, Thuc T

    2012-01-01

    Circulating tumour cells (CTC) are an important indicator of metastasis and associated with a poor prognosis. Detection sensitivity and specificity of CTC in the peripheral blood of metastatic cancer patient remain a technical challenge. Coherent anti-Stokes Raman scattering (CARS) microscopy was employed to examine the lipid content of CTC isolated from the peripheral blood of metastatic prostate cancer patients. CARS microscopy was also employed to evaluate lipid uptake and mobilization kinetics of a metastatic human prostate cancer cell line. One hundred CTC from eight metastatic prostate cancer patients exhibited strong CARS signal which arose from intracellular lipid. In contrast, leukocytes exhibited weak CARS signal which arose mostly from cellular membrane. On average, CARS signal intensity of prostate CTC was 7-fold higher than that of leukocytes (P<0.0000001). When incubated with human plasma, C4-2 metastatic human prostate cancer cells exhibited rapid lipid uptake kinetics and slow lipid mobilization kinetics. Higher expression of lipid transport proteins in C4-2 cells compared to non-transformed RWPE-1 and non-malignant BPH-1 prostate epithelial cells further indicated strong affinity for lipid of metastatic prostate cancer cells. Intracellular lipid could serve as a biomarker for prostate CTC which could be sensitively detected with CARS microscopy in a label-free manner. Strong affinity for lipid by metastatic prostate cancer cells could be used to improve detection sensitivity and therapeutic targeting of prostate CTC

  12. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  13. Alpha particles induce expression of immunogenic markers on tumour cells

    International Nuclear Information System (INIS)

    Gorin, J.B.; Gouard, S.; Cherel, M.; Davodeau, F.; Gaschet, J.; Morgenstern, A.; Bruchertseifer, F.

    2013-01-01

    The full text of the publication follows. Radioimmunotherapy (RIT) is an approach aiming at targeting the radioelements to tumours, usually through the use of antibodies specific for tumour antigens. The radiations emitted by the radioelements then induce direct killing of the targeted cells as well as indirect killing through bystander effect. Interestingly, it has been shown that ionizing radiations, in some settings of external radiotherapy, can foster an immune response directed against tumour cells. Our research team is dedicated to the development of alpha RIT, i.e RIT using alpha particle emitters, we therefore decided to study the effects of such particles on tumour cells in regards to their immunogenicity. First, we studied the effects of bismuth 213, an alpha emitter, on cellular death and autophagy in six different tumour cell lines. Then, we measured the expression of 'danger' signals and MHC molecules at the cell surface to determine whether irradiation with 213 Bi could cause the tumour cells to be recognized by the immune system. Finally a co-culture of dendritic cells with irradiated tumour cells was performed to test whether it would induce dendritic cells to mature. No apoptosis was detected within 48 hours after irradiation in any cell line, however half of them exhibited signs of autophagy. No increase in membrane expression of 'danger' signals was observed after treatment with 213 Bi, but we showed an increase in expression of MHC class I and II for some cell lines. Moreover, the co-culture experiment indicated that the immunogenicity of a human adenocarcinoma cell line (LS 174T) was enhanced in vitro after irradiation with alpha rays. These preliminary data suggest that alpha particles could be of interest in raising an immune response associated to RIT. (authors)

  14. Ambiguity of source location in acoustic emission technique

    International Nuclear Information System (INIS)

    Barat, P.; Mukherjee, P.; Kalyanasundaram, P.; Raj, B.

    1996-01-01

    Location of acoustic emission (AE) source in a plane is detected from the difference of the arrival times of the AE signal to at least three sensors placed on it. The detected location may not be unique in all cases. In this paper, the condition for the unambiguous solution for the location of the source has been deduced mathematically in terms of arrival times of the AE signal, the coordinate of the three sensors and the acoustic velocity. (author)

  15. Acoustic shadows help gleaning bats find prey, but may be defeated by prey acoustic camouflage on rough surfaces.

    Science.gov (United States)

    Clare, Elizabeth L; Holderied, Marc W

    2015-09-01

    Perceptual abilities of animals, like echolocating bats, are difficult to study because they challenge our understanding of non-visual senses. We used novel acoustic tomography to convert echoes into visual representations and compare these cues to traditional echo measurements. We provide a new hypothesis for the echo-acoustic basis of prey detection on surfaces. We propose that bats perceive a change in depth profile and an 'acoustic shadow' cast by prey. The shadow is more salient than prey echoes and particularly strong on smooth surfaces. This may explain why bats look for prey on flat surfaces like leaves using scanning behaviour. We propose that rather than forming search images for prey, whose characteristics are unpredictable, predators may look for disruptions to the resting surface (acoustic shadows). The fact that the acoustic shadow is much fainter on rougher resting surfaces provides the first empirical evidence for 'acoustic camouflage' as an anti-predator defence mechanism.

  16. Wilms' tumour (nephroblastoma)

    African Journals Online (AJOL)

    Wilms' tumour or nephroblastoma is a cancer of the kidney that ... It may be noticed by parents or it may be an incidental finding ... patients. It may lead to iron deficiency anaemia. Rarely Wilms' tumour may present with acquired von Willebrand's ... the best treatment approach. ... with multimodality therapy in paediatric.

  17. Influence of depth, time and human activity on detection rate of acoustic tags: a case study on two fish farms.

    Science.gov (United States)

    Otterå, H; Skilbrei, O T

    2016-03-01

    The detection rates of stationary acoustic transmitters deployed at three depths on two Atlantic salmon Salmo salar cage farms for c. 2 months were investigated. Deployment depth, time of day, day of the year and specific incidences at the farm substantially affected the rate of signal detection by the receiver. © 2016 The Authors. Journal of Fish Biology published by John Wiley & Sons Ltd on behalf of The Fisheries Society of the British Isles.

  18. World Conference on Acoustic Emission 2013

    CERN Document Server

    Wu, Zhanwen; Zhang, Junjiao

    2015-01-01

    This volume collects the papers from the 2013 World Conference on Acoustic Emission in Shanghai. The latest research and applications of Acoustic Emission (AE) are explored, with particular emphasis on detecting and processing of AE signals, development of AE instrument and testing standards, AE of materials, engineering structures and systems, including the processing of collected data and analytical techniques as well as experimental case studies.

  19. World Conference on Acoustic Emission 2015

    CERN Document Server

    Wu, Zhanwen; Zhang, Junjiao

    2017-01-01

    This volume collects the papers from the World Conference on Acoustic Emission 2015 (WCAE-2015) in Hawaii. The latest research and applications of Acoustic Emission (AE) are explored, with particular emphasis on detecting and processing of AE signals, development of AE instrument and testing standards, AE of materials, engineering structures and systems, including the processing of collected data and analytical techniques as well as experimental case studies.

  20. (18F)-fluorodeoxyglucose PET/CT in cervix cancer: Lymph node assessment and prognostic/predictive value of primary tumour analysis

    International Nuclear Information System (INIS)

    Leseur, J.; Williaume, D.; Le Prise, E.; De Crevoisier, R.; Devillers, A.; Garin, E.; Fougerou, C.; Bouriel, C.; Leveque, J.; Monpetit, E.; Blanchot, J.

    2011-01-01

    Purpose. - In cervix carcinoma: (a) to evaluate the ability of ( 18 F)-fluorodeoxyglucose (FDG) positron emission tomography (PET) in the lymph node detection; (b) to investigate the prognostic and predictive value of the primary cervical PET parameters. Patients and methods. - Ninety patients treated for cervix carcinoma and evaluated initially by MRI and FDG PET were included. The performances of FDG-PET for lymph node detection (relatively to the lymph node dissection) have been described (sensitivity, specificity, positive predictive value and negative predictive value). PET tumour parameters analyzed were: maximum standard uptake value (SUV max ), the volume and the maximum diameter. The prognostic and predictive values of these parameters were investigated. The tumour response was evaluated on surgical specimens. Results. - PET detected the cervical tumour with a sensitivity of 97% (mean values: SUV max = 15.8, volume = 27 mm 3 , maximum diameter = 47). For the detection of the lymph nodes, the values of sensibility, specificity, positive predictive value and negative predictive value were: 86, 56, 69 and 78% in the pelvic, and 90, 67, 50 and 95% for the para-aortic area, respectively. The SUV max was correlated with histologic response (P = 0.04). The frequency of partial histological response was significantly higher for tumour SUV max > 10.9 (P = 0.017). The maximum PET diameter and pathologic response had an impact on disease-free survival and overall survival in multivariate analysis (P < 0.05). Conclusion. - PET has high sensitivity in detecting pelvic and para-aortic lymph nodes. Some primary cervical tumour PET parameters are useful as prognostic and predictive factors. (authors)

  1. Prototype acoustic resonance spectroscopy monitor

    International Nuclear Information System (INIS)

    Sinha, D.N.; Olinger, C.T.

    1996-03-01

    This report reports on work performed for the International Atomic Energy Agency (IAEA) through the Program Office for Technical Assistance (POTAS). In this work, we investigate possible applications of nondestructive acoustics measurements to facilitate IAEA safeguards at bulk processing facilities. Two different acoustic techniques for verifying the internal structure of a processing tank were investigated. During this effort we also examined two acoustic techniques for assessing the fill level within a processing tank. The fill-level measurements could be made highly portable and have an added safeguards advantage that they can also detect stratification of fill material. This later application may be particularly useful in confirming the absence of stratification in plutonium processing tanks before accountability samples are withdrawn

  2. Study of green state ceramics damage by acoustic emission

    International Nuclear Information System (INIS)

    Kerboul, Genevieve

    1992-01-01

    Dry pressing is a delicate operation of the conventional process of elaboration of ceramic materials as most of the detected defects in sintered products are appearing during it, this research thesis reports the study of ceramic powder forming by using the non destructive technique of acoustic emission to detect defects in pressed samples as soon as they initiate. An original signal processing system has also been designed to analyse the effective value of acoustic signals emitted during pressing on industrial hydraulic presses, but comprising a single tooling. Three powders have been tested: UO_2, Al_2O_3 and a UO_2-PuO_2 mixture. In a first part, the author recalls some elements regarding the fabrication of nuclear fuel, knowledge on powder pressing, and general principles of acoustic emission. She reports a feasibility study and then defines experimental conditions. In the second part, she presents acoustic emission periods during a pressing cycle, and reports the study of the response of flawless and flawed pressed samples. She reports the examination of their evolution with respect to powder nature and to fabrication process parameters. She reports a detailed analysis of acoustic emission parameters as a basis to define the principle of operation of an in situ and real time detection of flawed pressed samples [fr

  3. Tumours and tumour-like conditions of the jaw seen in Zaria, Nigeria ...

    African Journals Online (AJOL)

    %) ameloblastomas; 33 (23.4%) fibrous dysplasia; 31 (22.0%) cemento-osseous dysplasia; 9 (6.4%) myxomas; 8 (5.7%) ameloblastic fibroma; and 3 (2.1%) adenomatoid odontogenic tumours; and 9 (6.4%) unclassified tumours. The benign ...

  4. A comparative study between mixed-type tumours from human salivary and canine mammary glands

    International Nuclear Information System (INIS)

    Genelhu, Marisa CLS; Cardoso, Sérgio V; Gobbi, Helenice; Cassali, Geovanni D

    2007-01-01

    In comparative pathology, canine mammary tumours have special interest because of their similarities with human breast cancer. Mixed tumours are uncommon lesions in the human breast, but they are found most frequently in the mammary gland of the female dogs and in the human salivary glands. The aim of the study was to compare clinical, morphological and immunohistochemical features of human salivary and canine mammary gland mixed tumours, in order to evaluate the latter as an experimental model for salivary gland tumours. Ten examples of each mixed tumour type (human pleomorphic adenoma and carcinomas ex-pleomorphic adenomas and canine mixed tumour and metaplastic carcinoma) were evaluated. First, clinical and morphologic aspects of benign and malignant variants were compared between the species. Then, streptavidin-biotin-peroxidase immunohistochemistry was performed to detect the expression of cytokeratins, vimentin, p63 protein, estrogen receptor, β-catenin, and E-cadherin. After standardization, similar age and site distributions were observed in human and canine tumours. Histological similarities were identified in the comparison of the benign lesions as well. Metaplastic carcinomas also resembled general aspects of carcinomas ex-pleomorphic adenomas in morphological evaluation. Additionally, immunohistochemical staining further presented similar antigenic expression between lesions. There are many similar features between human salivary and canine mammary gland mixed tumours. This observation is of great relevance for those interested in the study and management of salivary gland tumours, since canine lesions may constitute useful comparative models for their investigations

  5. Treatment delay of bone tumours, compilation of a sociodemographic risk profile: A retrospective study

    International Nuclear Information System (INIS)

    Schnurr, Christoph; Pippan, Mathias; Stuetzer, Hartmut; Delank, Karl S; Michael, Joern WP; Eysel, Peer

    2008-01-01

    Bone tumours are comparatively rare tumours and delays in diagnosis and treatment are common. The purpose of this study was to analyse sociodemographic risk factors for bone tumour patients in order to identify those at risk of prolonged patients delay (time span from first symptoms to consultation), professional delay (from consultation to treatment) or symptom interval (from first symptoms to treatment). Understanding these relationships might enable us to shorten time to diagnosis and therapy. We carried out a retrospective analysis of 265 patients with bone tumours documenting sociodemographic factors, patient delay, professional delay and symptom interval. A multivariate explorative Cox model was performed for each delay. Female gender was associated with a prolonged patient delay. Age under 30 years and rural living predisposes to a prolonged professional delay and symptom interval. Early diagnosis and prompt treatment are required for successful management of most bone tumour patients. We succeeded in identifying the histology independent risk factors of age under 30 years and rural habitation for treatment delay in bone tumour patients. Knowing about the existence of these risk groups age under 30 years and female gender could help the physician to diagnose bone tumours earlier. The causes for the treatment delays of patients living in a rural area have to be investigated further. If the delay initiates in the lower education of rural general physicians, further training about bone tumours might advance early detection. Hence the outcome of patients with bone tumours could be improved

  6. Tumour TIF1 mutations and loss of heterozygosity related to cancer-associated myositis.

    Science.gov (United States)

    Pinal-Fernandez, Iago; Ferrer-Fabregas, Berta; Trallero-Araguas, Ernesto; Balada, Eva; Martínez, Maria Angeles; Milisenda, Jose César; Aparicio-Español, Gloria; Labrador-Horrillo, Moises; Garcia-Patos, Vicente; Grau-Junyent, Josep M; Selva-O'Callaghan, Albert

    2018-02-01

    To analyse the influence of genetic alterations and differential expression of transcription intermediary factor 1 (TIF1) genes in the pathophysiology of cancer-associated myositis (CAM). Paired blood and tumour DNA samples from patients with anti-TIF1γ-positive CAM and from controls were analysed by whole-exome sequencing for the presence of somatic mutations and loss of heterozygosity (LOH) in their TIF1 genes. The genesis and maintenance of the autoimmune process were investigated immunohistochemically by studying TIF1γ expression in the different tissues involved in CAM (skin, muscle and tumour) based on the immunohistochemical H-score. From seven patients with anti-TIF1γ-positive CAM, we detected one somatic mutation and five cases of LOH in one or more of the four TIF1 genes compared with just one case of LOH in tumours from TIF1γ-negative myositis patients (86% vs 17%; P = 0.03). Compared with type-matched control tumours from non-myositis patients, TIF1γ staining was more intense in tumours from anti-TIF1γ-positive patients (H-score 255 vs 196; P = 0.01). Also, TIF1γ staining in muscle was slightly more intense in anti-TIF1γ-positive than in anti-TIF1γ-negative myositis (H-score 22 vs 5; P = 0.03). In contrast, intense TIF1γ staining was detected in the skin of both myositis and control patients. Tumours from paraneoplastic anti-TIF1γ-positive patients showed an increased number of genetic alterations, such as mutations and LOH, in TIF1 genes. These genetic alterations, in the context of a high expression of TIF1γ in the tumour, muscle and skin of these patients may be key to understanding the genesis of paraneoplastic myositis. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Immersed acoustical transducers and their potential uses in LMFBR

    International Nuclear Information System (INIS)

    Argous, J.P.; Brunet, M.; Baron, J.; Lhuillier, C.; Segui, J.L.

    1980-04-01

    Six years satisfactory operation in PHENIX has proved the reliability and effectivness of under-sodium viewing (VISUS) and Acoustic Detection. This fact has been strong incentive to maintain, on the future LMFBR the visus as well as the Acoustic Detection functions. These two functions are performed on SUPER PHENIX, by two sets of distinct systems using the well-known solution. Taking into account of recent improvements in sodium immersible acoustic transducers technology, CEA decided to undertake the development of a multi-functions instrument. This paper gives an outline of this new concept, which should be able to reduce the cost and the complexity of core instrumentation

  8. Primary bone tumours of the hand

    International Nuclear Information System (INIS)

    Kozlowski, K.; Azouz, E.M.; Campbell, J.; Marton, D.; Morris, L.; Padovani, J.; Sprague, P.; Beluffi, G.; Berzero, G.F.; Cherubino, P.; Adelaide Children's Hospital; Hospital for Children, Perth; Montreal Children's Hospital, Quebec; Saint Justine Hospital, Montreal, Quebec; Children's Hospital, Denver, CO; Hopital des Enfants, 13 - Marseille; Pavia Univ.; Pavia Univ.

    1988-01-01

    Twenty-one primary bone tumours of the hand in children from 8 paediatric hospitals are reported. Osteochondromas and enchondromas were not included. Our material consisted of 16 patients with common tumours (3 Ewing's sarcoma, 5 aneurysmal bone cyst, 6 osteoid osteoma and 2 epithelioma) and 5 patients with uncommon tumours (osteoma, simple bone cyst, haemangiopericytoma, capillary angiomatous tumour and benign ossifying fibroma or osteoblastoma). The X-ray diagnosis of the common tumours should have high concordance with histology, whereas that of uncommon tumours in much more difficult and uncertain. The characteristic features of Ewing's sarcoma are stressed as all our children with this tumour had a delayed diagnosis and a fatal outcome. Differential diagnosis with other short tubular bone lesions of the hand - specifically osteomyelitis - is discussed and the posibilities of microscopic diagnosis are stressed. (orig.)

  9. Intermedius nerve involvement and testing in acoustic neuromas.

    Science.gov (United States)

    Thomsen, J; Zilstorff, K

    1975-01-01

    The clinical findings in 125 patients with surgically confirmed acoustic neuromas are presented, with special regard to the involvement of the intermedius nerve in the diagnosis. In assessing the function of the intermedius nerve the examination of the nasolacrimal reflex and the sensation of taste on the anterior two-thirds of the tongue are used. The methods of investigation are described in detail. The material consisted of 20 medium-sized and 105 large tumours; no intracanalicular tumor was found. Hearing loss was the initial symptom in 85% of the patients, 10% had tinitus and 4% vertigo as the first symptom. Apart from the VIII cranial nerve symptoms, a defective nasolacrimal reflex was the most significant evidence of cerebellopontine angle pathology. The test was positive in 65% of the medium-sized tumours, in the entire material, 85%. The figures are higher than the incidence of trigeminal nerve symptoms. This in contrast to the reports of most authors. The tests described are simple and quick to perform, and it is emphasized that they should be applied to all patients with unilateral hearing loss of unknown origin.

  10. A pilot study to compare the detection of HPV-16 biomarkers in salivary oral rinses with tumour p16INK4a expression in head and neck squamous cell carcinoma patients

    International Nuclear Information System (INIS)

    Chai, Ryan C.; Lim, Yenkai; Frazer, Ian H.; Wan, Yunxia; Perry, Christopher; Jones, Lee; Lambie, Duncan; Punyadeera, Chamindie

    2016-01-01

    Human papilloma virus-16 (HPV-16) infection is a major risk factor for a subset of head and neck squamous cell carcinoma (HNSCC), in particular oropharyngeal squamous cell carcinoma (OPSCC). Current techniques for assessing the HPV-16 status in HNSCC include the detection of HPV-16 DNA and p16 INK4a expression in tumor tissues. When tumors originate from hidden anatomical sites, this method can be challenging. A non-invasive and cost-effective alternative to biopsy is therefore desirable for HPV-16 detection especially within a community setting to screen at-risk individuals. The present study compared detection of HPV-16 DNA and RNA in salivary oral rinses with tumor p16 INK4a status, in 82 HNSCC patients using end-point and quantitative polymerase chain reaction (PCR). Of 42 patients with p16 INK4a -positive tumours, 39 (sensitivity = 92.9 %, PPV = 100 % and NPV = 93 %) had oral rinse samples with detectable HPV-16 DNA, using end-point and quantitative PCR. No HPV-16 DNA was detected in oral rinse samples from 40 patients with p16 INK4a negative tumours, yielding a test specificity of 100 %. For patients with p16 INK4a positive tumours, HPV-16 mRNA was detected using end-point reverse transcription PCR (RT-PCR) in 24/40 (sensitivity = 60 %, PPV = 100 % and NPV = 71 %), and using quantitative RT-PCR in 22/40 (sensitivity = 55 %, PPV = 100 % and NPV = 69 %). No HPV-16 mRNA was detected in oral rinse samples from the p16 INK4a -negative patients, yielding a specificity of 100 %. We demonstrate that the detection of HPV-16 DNA in salivary oral rinse is indicative of HPV status in HNSCC patients and can potentially be used as a diagnostic tool in addition to the current methods. The online version of this article (doi:10.1186/s12885-016-2217-1) contains supplementary material, which is available to authorized users

  11. New methods for leaks detection and localisation using acoustic emission

    International Nuclear Information System (INIS)

    Boulanger, P.

    1993-01-01

    Real time monitoring of Pressurized Water nuclear Reactor secondary coolant system tends to integrate digital processing machines. In this context, the method of acoustic emission seems to exhibit good performances. Its principle is based on passive listening of noises emitted by local micro-displacements inside a material under stress which propagate as elastic waves. The lack of a priori knowledge on leak signals leads us to go deeper into understanding flow induced noise generation. Our studies are conducted using a simple leak model depending on the geometry and the king of flow inside the slit. Detection and localization problems are formulated according to the maximum likelihood principle. For detection, the methods using a indicator of similarity (correlation, higher order correlation) seems to give better results than classical ones (rms value, envelope, filter banks). For leaks location, a large panel of classical (generalized inter-correlation) and innovative (convolution, adaptative, higher order statistics) methods of time delay estimation are presented. The last part deals with the applications of higher order statistics. The analysis of higher order estimators of a non linear non Gaussian stochastic process family, the improvement of non linear prediction performances and the optimal-order choice problem are addressed in simple analytic cases. At last, possible applications to leak signals analysis are pointed out. (authors).264 refs., 7 annexes

  12. Bilateral disease and new trends in Wilms tumour

    Energy Technology Data Exchange (ETDEWEB)

    Owens, Catherine M.; Olsen, Oeystein E. [Great Ormond Street Hospital for Children NHS Trust, Department of Radiology, London (United Kingdom); Brisse, Herve J. [Institut Curie, Service de Radiodiagnostic, Paris (France); Begent, Joanna [University College Hospital, Paediatric Oncology, London (United Kingdom); Smets, Anne M. [Academic Medical Center Amsterdam, Department of Radiology, Amsterdam (Netherlands)

    2008-01-15

    Wilms tumour is a great therapeutic success story within paediatric oncology; its prognosis is excellent. Although mainly sporadic, occurring in otherwise well children, it occurs in a small number of genetically predisposed children. Thus regular surveillance imaging is performed in predisposed children in parts of the USA and Europe. The risks and benefits of surveillance are unclear, as the existing ad-hoc surveillance protocols are lacking in consistency of practice and equity of provision. We present guidelines for Wilms tumour surveillance based on a review of current practice and available evidence, outlined by a multidisciplinary working group in the UK. Wilms tumours are bilateral in 4-13% of affected children. Bilateral synchronous nephroblastomas are observed in 5% of affected children and are usually associated with the presence of nephrogenic rests, congenital malformations and predisposing syndromes. The major challenge in bilateral disease is to achieve a cure and at the same time to preserve sufficient functional renal tissue for normal growth and development. The association among Wilms tumour, nephrogenic rests and nephroblastomatosis makes detection and characterization of renal lesions with imaging extremely important. We discuss the relative strengths and weaknesses of the different modalities used for diagnosis and follow-up in bilateral renal disease. We also discuss newly emerging diagnostic imaging tests such as {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET). This technique, when fused with CT (PET-CT), allows accelerated metabolic activity to be accurately anatomically localised and so is potentially useful for staging, assessment of treatment response, and for surgical and radiotherapy planning. In addition, quantitative MRI techniques have been proved to be valuable in intracranial tumours, but no such role has been validated in abdominal disease. Diffusion-weighted imaging with calculation of ADC maps is feasible in

  13. Bilateral disease and new trends in Wilms tumour

    International Nuclear Information System (INIS)

    Owens, Catherine M.; Olsen, Oeystein E.; Brisse, Herve J.; Begent, Joanna; Smets, Anne M.

    2008-01-01

    Wilms tumour is a great therapeutic success story within paediatric oncology; its prognosis is excellent. Although mainly sporadic, occurring in otherwise well children, it occurs in a small number of genetically predisposed children. Thus regular surveillance imaging is performed in predisposed children in parts of the USA and Europe. The risks and benefits of surveillance are unclear, as the existing ad-hoc surveillance protocols are lacking in consistency of practice and equity of provision. We present guidelines for Wilms tumour surveillance based on a review of current practice and available evidence, outlined by a multidisciplinary working group in the UK. Wilms tumours are bilateral in 4-13% of affected children. Bilateral synchronous nephroblastomas are observed in 5% of affected children and are usually associated with the presence of nephrogenic rests, congenital malformations and predisposing syndromes. The major challenge in bilateral disease is to achieve a cure and at the same time to preserve sufficient functional renal tissue for normal growth and development. The association among Wilms tumour, nephrogenic rests and nephroblastomatosis makes detection and characterization of renal lesions with imaging extremely important. We discuss the relative strengths and weaknesses of the different modalities used for diagnosis and follow-up in bilateral renal disease. We also discuss newly emerging diagnostic imaging tests such as 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET). This technique, when fused with CT (PET-CT), allows accelerated metabolic activity to be accurately anatomically localised and so is potentially useful for staging, assessment of treatment response, and for surgical and radiotherapy planning. In addition, quantitative MRI techniques have been proved to be valuable in intracranial tumours, but no such role has been validated in abdominal disease. Diffusion-weighted imaging with calculation of ADC maps is feasible in

  14. EpCAM as multi-tumour target for near-infrared fluorescence guided surgery

    International Nuclear Information System (INIS)

    Driel, P. B. A. A. van; Boonstra, M. C.; Prevoo, H. A. J. M.; Giessen, M. van de; Snoeks, T. J. A.; Tummers, Q. R. J. G.; Keereweer, S.; Cordfunke, R. A.; Fish, A.; Eendenburg, J. D. H. van; Lelieveldt, B. P. F.; Dijkstra, J.; Velde, C. J. H. van de; Kuppen, P. J. K.; Vahrmeijer, A. L.; Löwik, C. W. G. M.; Sier, C. F. M.

    2016-01-01

    Evaluation of resection margins during cancer surgery can be challenging, often resulting in incomplete tumour removal. Fluorescence-guided surgery (FGS) aims to aid the surgeon to visualize tumours and resection margins during surgery. FGS relies on a clinically applicable imaging system in combination with a specific tumour-targeting contrast agent. In this study EpCAM (epithelial cell adhesion molecule) is evaluated as target for FGS in combination with the novel Artemis imaging system. The NIR fluorophore IRDye800CW was conjugated to the well-established EpCAM specific monoclonal antibody 323/A3 and an isotype IgG1 as control. The anti-EpCAM/800CW conjugate was stable in serum and showed preserved binding capacity as evaluated on EpCAM positive and negative cell lines, using flow cytometry and cell-based plate assays. Four clinically relevant orthotopic tumour models, i.e. colorectal cancer, breast cancer, head and neck cancer, and peritonitis carcinomatosa, were used to evaluate the performance of the anti-EpCAM agent with the clinically validated Artemis imaging system. The Pearl Impulse small animal imaging system was used as reference. The specificity of the NIRF signal was confirmed using bioluminescence imaging and green-fluorescent protein. All tumour types could clearly be delineated and resected 72 h after injection of the imaging agent. Using NIRF imaging millimetre sized tumour nodules were detected that were invisible for the naked eye. Fluorescence microscopy demonstrated the distribution and tumour specificity of the anti-EpCAM agent. This study shows the potential of an EpCAM specific NIR-fluorescent agent in combination with a clinically validated intraoperative imaging system to visualize various tumours during surgery

  15. Immunosuppressive mediators of oral squamous cell carcinoma in tumour samples and saliva.

    Science.gov (United States)

    Gonçalves, Andréia Souza; Arantes, Diego Antonio Costa; Bernardes, Vanessa Fátima; Jaeger, Filipe; Silva, Janine Mayra; Silva, Tarcília Aparecida; Aguiar, Maria Cássia Ferreira; Batista, Aline Carvalho

    2015-01-01

    The goal of this study was to compare the salivary concentrations of IL-10, TGF-β1 and soluble HLA-G (sHLA-G) in patients with oral squamous cell carcinoma (OSCC) to those in healthy individuals (control group), and to correlate the expression of these mediators in saliva with that in the tumour microenvironment. Neoplastic tissue and saliva samples from patients with OSCC (n=22) were analysed by immunohistochemistry and enzyme-linked immunosorbent assay (ELISA) respectively. We detected high expression of IL-10 and HLA-G in the tumour microenvironment when compared to healthy oral mucosa samples. Determination of IL-10 salivary concentration enabled us to distinguish patients with OSCC from healthy individuals (P=0.038), which showed correlation with tissue expression of this cytokine. HLA-G salivary release was similar in both groups (P=0.17) and no correlation with tumour expression was observed. TGF-β1 expression was low or absent in tumours, and salivary concentration was similar between groups. Our results suggest that of the three markers analysed, IL-10 is a potential salivary biomarker. Furthermore, the elevated expression of HLA-G and IL-10 in tumour sites could favour the escape of tumour cells from immune defense mechanisms. Copyright © 2014 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

  16. Experimental studies of the acoustic detection of particle showers

    International Nuclear Information System (INIS)

    Sulak, L.R.; Bowen, T.; Pifer, B.

    1977-01-01

    The scale and characteristics required of a detector that will measure ultrahigh-energy cosmic ray neutrino interactions have been studied in detail. Results obtained to date in observing acoustic signals from hadronic showers both at Brookhaven National Laboratory (BNL) and Harvard University are reported. It is suggested that ultrasonic particle detection is possible, currently down to the level of 10 14 eV. This simple, inexpensive technique may be ideal for observing the secondaries produced in a massive (10 9 ton) neutrino detector. Three experimental tests were performed to determine if showers produce detectable sonic signals as recently predicted. One at the 200-MeV linac at BNL used heavily ionizing protons stopping in water (range = 30 cm) with total energy depositions between 10 19 and 20 21 eV and deposition times ranging from 3 μs to 200 μs. The diameter of the beam was fixed at 6 cm (a characteristic time of 30 μs). A similar test was done at the 160-MeV cyclotron at Harvard, where the energy deposition could be decreased to 10 15 eV. A third test was done with minimum ionizing protons from the 28-GeV fast extracted beam at BNL. As in the BNL linac test, the beam could not be tuned below energy depositions of 10 19 . Typically 3 x 10 11 protons traversed 30 cm of water during a deposition time of 2 μs with a beam diameter variable between 5 and 20 cm

  17. Tipping point analysis of ocean acoustic noise

    Science.gov (United States)

    Livina, Valerie N.; Brouwer, Albert; Harris, Peter; Wang, Lian; Sotirakopoulos, Kostas; Robinson, Stephen

    2018-02-01

    We apply tipping point analysis to a large record of ocean acoustic data to identify the main components of the acoustic dynamical system and study possible bifurcations and transitions of the system. The analysis is based on a statistical physics framework with stochastic modelling, where we represent the observed data as a composition of deterministic and stochastic components estimated from the data using time-series techniques. We analyse long-term and seasonal trends, system states and acoustic fluctuations to reconstruct a one-dimensional stochastic equation to approximate the acoustic dynamical system. We apply potential analysis to acoustic fluctuations and detect several changes in the system states in the past 14 years. These are most likely caused by climatic phenomena. We analyse trends in sound pressure level within different frequency bands and hypothesize a possible anthropogenic impact on the acoustic environment. The tipping point analysis framework provides insight into the structure of the acoustic data and helps identify its dynamic phenomena, correctly reproducing the probability distribution and scaling properties (power-law correlations) of the time series.

  18. Tipping point analysis of ocean acoustic noise

    Directory of Open Access Journals (Sweden)

    V. N. Livina

    2018-02-01

    Full Text Available We apply tipping point analysis to a large record of ocean acoustic data to identify the main components of the acoustic dynamical system and study possible bifurcations and transitions of the system. The analysis is based on a statistical physics framework with stochastic modelling, where we represent the observed data as a composition of deterministic and stochastic components estimated from the data using time-series techniques. We analyse long-term and seasonal trends, system states and acoustic fluctuations to reconstruct a one-dimensional stochastic equation to approximate the acoustic dynamical system. We apply potential analysis to acoustic fluctuations and detect several changes in the system states in the past 14 years. These are most likely caused by climatic phenomena. We analyse trends in sound pressure level within different frequency bands and hypothesize a possible anthropogenic impact on the acoustic environment. The tipping point analysis framework provides insight into the structure of the acoustic data and helps identify its dynamic phenomena, correctly reproducing the probability distribution and scaling properties (power-law correlations of the time series.

  19. Acoustic signal analysis in the creeping discharge

    International Nuclear Information System (INIS)

    Nakamiya, T; Sonoda, Y; Tsuda, R; Ebihara, K; Ikegami, T

    2008-01-01

    We have previously succeeded in measuring the acoustic signal due to the dielectric barrier discharge and discriminating the dominant frequency components of the acoustic signal. The dominant frequency components appear over 20kHz of acoustic signal by the dielectric barrier discharge. Recently surface discharge control technology has been focused from practical applications such as ozonizer, NO X reactors, light source or display. The fundamental experiments are carried to examine the creeping discharge using the acoustic signal. When the high voltage (6kV, f = 10kHz) is applied to the electrode, the discharge current flows and the acoustic sound is generated. The current, voltage waveforms of creeping discharge and the sound signal detected by the condenser microphone are stored in the digital memory scope. In this scheme, Continuous Wavelet Transform (CWT) is applied to discriminate the acoustic sound of the micro discharge and the dominant frequency components are studied. CWT results of sound signal show the frequency spectrum of wideband up to 100kHz. In addition, the energy distributions of acoustic signal are examined by CWT

  20. Acoustic Predictors of Pediatric Dysarthria in Cerebral Palsy

    Science.gov (United States)

    Allison, Kristen M.; Hustad, Katherine C.

    2018-01-01

    Purpose: The objectives of this study were to identify acoustic characteristics of connected speech that differentiate children with dysarthria secondary to cerebral palsy (CP) from typically developing children and to identify acoustic measures that best detect dysarthria in children with CP. Method: Twenty 5-year-old children with dysarthria…

  1. Detection of benign hilar bile duct stenoses - A retrospective analysis in 250 patients with suspicion of Klatskin tumour.

    Science.gov (United States)

    Scheuermann, Uwe; Widyaningsih, Rizky; Hoppe-Lotichius, Maria; Heise, Michael; Otto, Gerd

    2016-06-01

    The aim of this study was to identify clinical, laboratory and radiological parameters to distinguish benign from malignant stenoses of the proximal bile duct. Between 1997 and 2011, 250 patients were referred to our clinic with hilar bile duct stenoses suspicious for Klatskin tumour. Medical histories, clinical data, pre-interventional laboratory tests, imaging findings, as well as therapeutic approach and patient outcome were compared to final histological results. All data were retrieved from our prospectively maintained database and analysed retrospectively. We found benign bile duct lesions in 34 patients (13.6%). Among the entire study population, uni- and multivariate analyses of 18 clinicopathological parameters revealed that patient age, serum alkaline phosphatase, tumour marker CA19-9 and presence of tumour mass in computed tomography were independent predictors for malignant biliary stenoses (p hilar biliary stenoses of 74.6%, 80.0% and 83.5%, respectively. Surgical resection could be avoided by preoperative work-up and surgical exploration in 10 out of 34 patients with benign lesions. Rates of major liver resections performed were 66.7% in the benign lesion group and 90.7% in the Klatskin tumour group. Despite improvements of preoperative diagnostics, it remains difficult to differentiate between benign and malignant hilar bile duct stenosis. Even explorative laparotomy was not able to safely exclude Klatskin tumour in all cases and therefore major liver resection was inevitable.

  2. Comparison of tumour age response to radiation for cells derived from tissue culture or solid tumours

    International Nuclear Information System (INIS)

    Keng, P.C.; Siemann, D.W.; Rochester Univ., NY; Rochester Univ., NY; Wheeler, K.T.

    1984-01-01

    Direct comparison of the cell age response of 9L and KHT tumour cells derived either from tissue culture or solid tumours was achieved. Cells from dissociated KHT and 9L tumours (the latter implanted either subcutaneously or intracerebrally) and cells from tissue culture were separated into homogenous sized populations by centrifugal elutriation. In both tumour models these homogeneous sized populations correspond to populations enriched at different stages of the cell cycle. The survival of these elutriated cell populations was measured after a single dose of Cs-137 gamma rays. For cells isolated from 9L solid tumours, there was little variation in radiosensitivity throughout the cell cycle; however, a very small but significant increase in resistance was found in late G 1 cells. This lack of a large variation in radiosensitivity through the cell cycle for 9L cells from solid tumours also was seen in 9L cells growing in monolayer tissue culture. When similar experiments were performed using the KHT sarcoma tumour model, the results showed that KHT cells in vitro exhibited a fairly conventional increase in radioresistance in both mid G 1 and late S. However, the cell age response of KHT cells from solid tumours was different; particularly in the late S and G 2 + M phases. (author)

  3. Continental-shelf Scale Passive Ocean AcousticWaveguide Remote Sensing of Marine Mammals and other Submerged Objects including Detection, Localization, and Classification

    Science.gov (United States)

    Wang, Delin

    In this thesis, we develop the basics of the Passive Ocean Acoustic Waveguide Remote Sensing (POAWRS) technique for the instantaneous continental-shelf scale detection, localization and species classification of marine mammal vocalizations. POAWRS uses a large-aperture, densely sampled coherent hydrophone array system with orders of magnitude higher array gain to enhance signal-to-noise ratios (SNR) by coherent beamforming, enabling detection of underwater acoustic signals either two orders of magnitude more distant in range or lower in SNR than a single hydrophone. The ability to employ coherent spatial processing of signals with the POAWRS technology significantly improves areal coverage, enabling detection of oceanic sound sources over instantaneous wide areas spanning 100 km or more in diameter. The POAWRS approach was applied to analyze marine mammal vocalizations from diverse species received on a 160-element Office Naval Research Five Octave Research Array (ONR-FORA) deployed during their feeding season in Fall 2006 in the Gulf of Maine. The species-dependent temporal-spatial distribution of marine mammal vocalizations and correlation to the prey fish distributions have been determined. Furthermore, the probability of detection regions, source level distributions and pulse compression gains of the vocalization signals from diverse marine mammal species have been estimated. We also develop an approach for enhancing the angular resolution and improving bearing estimates of acoustic signals received on a coherent hydrophone array with multiple-nested uniformly-spaced subapertures, such as the ONR-FORA, by nonuniform array beamforming. Finally we develop a low-cost non-oil-filled towable prototype hydrophone array that consists of eight hydrophone elements with real-time data acquisition and 100 m tow cable. The approach demonstrated here will be applied in the development of a full 160 element POAWRS-type low-cost coherent hydrophone array system in the future.

  4. MRI characteristics of midbrain tumours

    International Nuclear Information System (INIS)

    Sun, B.; Wang, C.C.; Wang, J.

    1999-01-01

    We diagnosed 60 cases of midbrain tumours by MRI between 1993 to 1997. There were 39 males and 21 females, aged 2-64 years, mean 25.6 years. We found 38 patients with true intramedullary midbrain tumours, 11 predominantly in the tectum, 20 in the tegmentum and 7 with a downward extension to the pons; there were 7 within the cerebral aqueduct. There were 22 patients with infiltrating midbrain tumours extending from adjacent structures, 11 cases each from the thalamus and pineal region. All patients received surgical treatment. Gross total resection was achieved in 42 cases, subtotal (> 75 %) resection in 18. Pathological diagnoses included 16 low-grade and 15 high-grade astrocytomas; 5 oligodendroastrocytomas; 2 ependymomas; 11 glioblastomas; and 11 pineal parenchymal or germ-cell tumours. Midbrain tumours are a heterogeneous group of neoplasms, with wide variation in clinical and MRI features, related to the site and type of tumour. MRI not only allows precise analysis of their growth pattern, but also can lead to a correct preoperative diagnosis in the majority of cases. (orig.) (orig.)

  5. Retroperitoneal Malignant Peripheral Nerve Sheath Tumour: A Rare Case Report.

    Science.gov (United States)

    Deger, Ayse Nur; Bayar, Mehmet Akif; Caydere, Muzaffer; Deger, Hakki; Tayfur, Mahir

    2015-09-01

    Malignant nerve sheath tumours (MPNST) are rare neoplasias and retroperitoneal cases are fairly rare and clinically difficult to be detected, but they are very agressive neoplasias. MPNST are frequently seen in head, neck and upper extremities. In patients with NF1; MPNST, a poor-prognostic lesion, may result from a malignant degeneration of a former plexiform neurofibroma. It is necessary to be aware of a potential malignancy in patients diagnosed with plexiform neurofibroma. We present a 21-year-old female with a diagnosis of MPNST. The patient was admited to the hospital because of a tumour in the subcutaneous region on her left buttock. The surgeon's clinical diagnosis was lipoma. After the pathological examination of biopsy specimen, the lesion was identified as "plexiform neurofibroma" and then the patient was diagnosed with Neurofibromatosis Type 1 (NF1). Simultaneously, another mass on the retroperitoneal region was identified as malignant peripheral nerve sheath tumour (MPNST).

  6. Sci—Fri AM: Mountain — 04: Label-free Raman spectroscopy of single tumour cells detects early radiation-induced glycogen synthesis associated with increased radiation resistance

    International Nuclear Information System (INIS)

    Matthews, Q; Lum, JJ; Isabelle, M; Harder, S; Jirasek, A; Brolo, AG

    2014-01-01

    Purpose: To use label-free Raman spectroscopy (RS) for early treatment monitoring of tumour cell radioresistance. Methods: Three human tumour cell lines, two radioresistant (H460, SF 2 = 0.57 and MCF7, SF 2 = 0.70) and one radiosensitive (LNCaP, SF 2 = 0.36), were irradiated with single fractions of 2, 4, 6, 8 or 10 Gy. In additional experiments, H460 and MCF7 cells were irradiated under co-treatment with the anti-diabetic drug metformin, a known radiosensitizing agent. Treated and control cultures were analyzed with RS daily for 3 days post-treatment. Single-cell Raman spectra were acquired from 20 live cells per sample, and experiments were repeated in triplicate. The combined data sets were analyzed with principal component analysis using standard algorithms. Cells from each culture were also subjected to standard assays for viability, proliferation, cell cycle, and radiation clonogenic survival. Results: The radioresistant cells (H460, MCF7) exhibited a RS molecular radiation response signature, detectable as early as 1 day post-treatment, of which radiation-induced glycogen synthesis is a significant contributor. The radiosensitive cells (LNCaP) exhibited negligible glycogen synthesis. Co-treatment with metformin in MCF7 cells blocked glycogen synthesis, reduced viability and proliferation, and increased radiosensitivity. Conversely, metformin co-treatment in H460 cells did not produce these same effects; importantly, both radiation-induced synthesis of glycogen and radiosensitivity were unaffected. Conclusions: Label-free RS can detect early glycogen synthesis post-irradiation, a previously undocumented metabolic mechanism associated with tumour cell radioresistance that can be targeted to increase radiosensitivity. RS monitoring of intratumoral glycogen may provide new opportunities for personalized combined modality radiotherapy treatments

  7. Sci—Fri AM: Mountain — 04: Label-free Raman spectroscopy of single tumour cells detects early radiation-induced glycogen synthesis associated with increased radiation resistance

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, Q; Lum, JJ [BC Cancer Agency — Vancouver Island Centre (Canada); Isabelle, M; Harder, S; Jirasek, A [Physics and Astronomy, University of Victoria (Australia); Brolo, AG [Chemistry, University of Victoria (Australia)

    2014-08-15

    Purpose: To use label-free Raman spectroscopy (RS) for early treatment monitoring of tumour cell radioresistance. Methods: Three human tumour cell lines, two radioresistant (H460, SF{sub 2} = 0.57 and MCF7, SF{sub 2} = 0.70) and one radiosensitive (LNCaP, SF{sub 2} = 0.36), were irradiated with single fractions of 2, 4, 6, 8 or 10 Gy. In additional experiments, H460 and MCF7 cells were irradiated under co-treatment with the anti-diabetic drug metformin, a known radiosensitizing agent. Treated and control cultures were analyzed with RS daily for 3 days post-treatment. Single-cell Raman spectra were acquired from 20 live cells per sample, and experiments were repeated in triplicate. The combined data sets were analyzed with principal component analysis using standard algorithms. Cells from each culture were also subjected to standard assays for viability, proliferation, cell cycle, and radiation clonogenic survival. Results: The radioresistant cells (H460, MCF7) exhibited a RS molecular radiation response signature, detectable as early as 1 day post-treatment, of which radiation-induced glycogen synthesis is a significant contributor. The radiosensitive cells (LNCaP) exhibited negligible glycogen synthesis. Co-treatment with metformin in MCF7 cells blocked glycogen synthesis, reduced viability and proliferation, and increased radiosensitivity. Conversely, metformin co-treatment in H460 cells did not produce these same effects; importantly, both radiation-induced synthesis of glycogen and radiosensitivity were unaffected. Conclusions: Label-free RS can detect early glycogen synthesis post-irradiation, a previously undocumented metabolic mechanism associated with tumour cell radioresistance that can be targeted to increase radiosensitivity. RS monitoring of intratumoral glycogen may provide new opportunities for personalized combined modality radiotherapy treatments.

  8. Proliferation index: a continuous model to predict prognosis in patients with tumours of the Ewing's sarcoma family.

    Directory of Open Access Journals (Sweden)

    Samantha Brownhill

    Full Text Available The prognostic value of proliferation index (PI and apoptotic index (AI, caspase-8, -9 and -10 expression have been investigated in primary Ewing's sarcoma family of tumours (ESFT. Proliferating cells, detected by immunohistochemistry for Ki-67, were identified in 91% (91/100 of tumours with a median PI of 14 (range 0-87. Apoptotic cells, identified using the TUNEL assay, were detected in 96% (76/79 of ESFT; the median AI was 3 (range 0-33. Caspase-8 protein expression was negative (0 in 14% (11/79, low (1 in 33% (26/79, medium (2 in 38% (30/79 and high (3 in 15% (12/79 of tumours, caspase-9 expression was low (1 in 66% (39/59 and high (3 in 34% (20/59, and caspase-10 protein was low (1 in 37% (23/62 and negative (0 in 63% (39/62 of primary ESFT. There was no apparent relationship between caspase-8, -9 and -10 expression, PI and AI. PI was predictive of relapse-free survival (RFS; p = 0.011 and overall survival (OS; p = <0.001 in a continuous model, whereas AI did not predict outcome. Patients with tumours expressing low levels of caspase-9 protein had a trend towards a worse RFS than patients with tumours expressing higher levels of caspase-9 protein (p = 0.054, log rank test, although expression of caspases-8, -9 and/or -10 did not significantly predict RFS or OS. In a multivariate analysis model that included tumour site, tumour volume, the presence of metastatic disease at diagnosis, PI and AI, PI independently predicts OS (p = 0.003. Consistent with previous publications, patients with pelvic tumours had a significantly worse OS than patients with tumours at other sites (p = 0.028; patients with a pelvic tumour and a PI≥20 had a 6 fold-increased risk of death. These studies advocate the evaluation of PI in a risk model of outcome for patients with ESFT.

  9. Neurofibromatosis type 1: brain stem tumours

    International Nuclear Information System (INIS)

    Bilaniuk, L.T.; Molloy, P.T.; Zimmerman, R.A.; Phillips, P.C.; Vaughan, S.N.; Liu, G.T.; Sutton, L.N.; Needle, M.

    1997-01-01

    We describe the clinical and imaging findings of brain stem tumours in patients with neurofibromatosis type 1 (NF1). The NF1 patients imaged between January 1984 and January 1996 were reviewed and 25 patients were identified with a brain stem tumour. Clinical, radiographical and pathological results were obtained by review of records and images. Brain stem tumour identification occurred much later than the clinical diagnosis of NF1. Medullary enlargement was most frequent (68 %), followed by pontine (52 %) and midbrain enlargement (44 %). Patients were further subdivided into those with diffuse (12 patients) and those with focal (13 patients) tumours. Treatment for hydrocephalus was required in 67 % of the first group and only 15 % of the second group. Surgery was performed in four patients and revealed fibrillary astrocytomas, one of which progressed to an anaplastic astrocytoma. In 40 % of patients both brain stem and optic pathway tumours were present. The biological behaviour of brain stem tumours in NF1 is unknown. Diffuse tumours in the patients with NF1 appear to have a much more favourable prognosis than patients with similar tumours without neurofibromatosis type 1. (orig.). With 7 figs., 3 tabs

  10. Parotid gland tumours: MR tractography to assess contact with the facial nerve.

    Science.gov (United States)

    Attyé, Arnaud; Karkas, Alexandre; Troprès, Irène; Roustit, Matthieu; Kastler, Adrian; Bettega, Georges; Lamalle, Laurent; Renard, Félix; Righini, Christian; Krainik, Alexandre

    2016-07-01

    To assess the feasibility of intraparotid facial nerve (VIIn) tractographic reconstructions in estimating the presence of a contact between the VIIn and the tumour, in patients requiring surgical resection of parotid tumours. Patients underwent MR scans with VIIn tractography calculated with the constrained spherical deconvolution model. The parameters of the diffusion sequence were: b-value of 1000 s/mm(2); 32 directions; voxel size: 2 mm isotropic; scan time: 9'31'. The potential contacts between VIIn branches and tumours were estimated with different initial fractional anisotropy (iFA) cut-offs compared to surgical data. Surgeons were blinded to the tractography reconstructions and identified both nerves and contact with tumours using nerve stimulation and reference photographs. Twenty-six patients were included in this study and the mean patient age was 55.2 years. Surgical direct assessment of VIIn allowed identifying 0.1 as the iFA threshold with the best sensitivity to detect tumour contact. In all patients with successful VIIn identification by tractography, surgeons confirmed nerve courses as well as lesion location in parotid glands. Mean VIIn branch FA values were significantly lower in cases with tumour contact (t-test; p ≤ 0.01). This study showed the feasibility of intraparotid VIIn tractography to identify nerve contact with parotid tumours. • Diffusion imaging is an efficient method for highlighting the intraparotid VIIn. • Visualization of the VIIn may help to better manage patients before surgery. • We bring new insights to future trials for patients with VIIn dysfunction. • We aimed to provide radio-anatomical references for further studies.

  11. Dual output acoustic wave sensor for molecular identification

    International Nuclear Information System (INIS)

    Frye, G.C.; Martin, S.J.

    1991-01-01

    This patent describes an apparatus for detecting and identifying at least one unknown chemical species. It comprises: an acoustic wave device capable of generating, transmitting and receiving an acoustic wave, means for measuring the velocity of an acoustic wave travelling through the material; means for simultaneously measuring the attenuation of the acoustic wave traveling through the coating material; sampling means to contact the acoustic wave device to the unknown chemical species; means for determining the changes in both the attenuation and velocity values of the acoustic wave upon sorption of the unknown chemical species into the coating material; and means for correlating the magnitudes of the changes of velocity with respect to the changes of the attenuations of the acoustic wave; and means for comparing the values of the velocity and attenuation changes to known values of velocity and attenuation of known chemical species in order to identify the unknown sorbed chemical species

  12. Acoustic lenses

    International Nuclear Information System (INIS)

    Kittmer, C.A.

    1983-03-01

    Acoustic lenses focus ultrasound to produce pencil-like beams with reduced near fields. When fitted to conventional (flat-faced) transducers, such lenses greatly improve the ability to detect and size defects. This paper describes a program developed to design acoustic lenses for use in immersion or contact inspection, using normal or angle beam mode with flat or curved targets. Lens surfaces are circular in geometry to facilitate machining. For normal beam inspection of flat plate, spherical or cylindrical lenses are used. For angle beam or curved surface inspections, a compound lens is required to correct for the extra induced aberration. Such a lens is aspherical with one radius of curvature in the plane of incidence, and a different radius of curvature in the plane perpendicular to the incident plane. The resultant beam profile (i.e., location of the acoustic focus, beam diameter, 6 dB working range) depends on the degree of focusing and the transducer used. The operating frequency and bandwidth can be affected by the instrumentation used. Theoretical and measured beam profiles are in good agreement. Various applications, from zone focusing used for defect sizing in thick plate, to line focusing for pipe weld inspection, are discussed

  13. Dual-tree complex wavelet transform and SVD based acoustic noise reduction and its application in leak detection for natural gas pipeline

    Science.gov (United States)

    Yu, Xuchao; Liang, Wei; Zhang, Laibin; Jin, Hao; Qiu, Jingwei

    2016-05-01

    During the last decades, leak detection for natural gas pipeline has become one of the paramount concerns of pipeline operators and researchers across the globe. However, acoustic wave method has been proved to be an effective way to identify and localize leakage for gas pipeline. Considering the fact that noises inevitably exist in the acoustic signals collected, noise reduction should be enforced on the signals for subsequent data mining and analysis. Thus, an integrated acoustic noise reduction method based on DTCWT and SVD is proposed in this study. The method is put forward based on the idea that noise reduction strategy should match the characteristics of the noisy signal. According to previous studies, it is known that the energy of acoustic signals collected under leaking condition is mainly concentrated in low-frequency portion (0-100 Hz). And ultralow-frequency component (0-5 Hz), which is taken as the characteristic frequency band in this study, can propagate a relatively longer distance and be captured by sensors. Therefore, in order to filter the noises and to reserve the characteristic frequency band, DTCWT is taken as the core to conduct multilevel decomposition and refining for acoustic signals and SVD is employed to eliminate noises in non-characteristic bands. Both simulation and field experiments show that DTCWT-SVD is an excellent method for acoustic noise reduction. At the end of this study, application in leakage localization shows that it becomes much easier and a little more accurate to estimate the location of leak hole after noise reduction by DTCWT-SVD.

  14. An Original Approach for Quantification of Blood Vessels on the Whole Tumour Section

    Directory of Open Access Journals (Sweden)

    Nga Tran Kim

    2003-01-01

    Full Text Available Relative abundance of tumour angiogenesis has been shown to be of clinical relevance in cancers of various locations such as the ovary. Nevertheless, several problems are encountered when quantifying tumour microvessels: (i as many other tumour markers, vascularity pattern is often heterogeneous within the tumour mass and even within the same histological section. As a consequence, an adequate acquisition method must be developed for accurate field sampling. (ii Manual microvessel counting is long, tedious and subject to poor reproducibility. Introduction in routine practice requires a fast, reproducible and reliable automatic image processing. In this study we present an original procedure combining a slide scanner image acquisition and a fully automatic image analysis sequence. The slide scanner offers the advantage of recording an image of the whole histological section for subsequent automatic blood vessel detection and hot spot area location. Microvessel density and surface fraction were measured for the whole section as well as within hot spots. Different immunostaining methods were tested in order to optimise the procedure. Moreover, the method proposed was submitted to a quality control procedure, with reference to interactive identification of microvessels at scanner level. This experiment showed that 93 to 97% of blood vessels were detected, according to the staining protocol used. Colour figures can be viewed on http://www.esacp.org/acp/2003/25‐2/kim.htm.

  15. Bearing Fault Detection Based on Empirical Wavelet Transform and Correlated Kurtosis by Acoustic Emission.

    Science.gov (United States)

    Gao, Zheyu; Lin, Jing; Wang, Xiufeng; Xu, Xiaoqiang

    2017-05-24

    Rolling bearings are widely used in rotating equipment. Detection of bearing faults is of great importance to guarantee safe operation of mechanical systems. Acoustic emission (AE), as one of the bearing monitoring technologies, is sensitive to weak signals and performs well in detecting incipient faults. Therefore, AE is widely used in monitoring the operating status of rolling bearing. This paper utilizes Empirical Wavelet Transform (EWT) to decompose AE signals into mono-components adaptively followed by calculation of the correlated kurtosis (CK) at certain time intervals of these components. By comparing these CK values, the resonant frequency of the rolling bearing can be determined. Then the fault characteristic frequencies are found by spectrum envelope. Both simulation signal and rolling bearing AE signals are used to verify the effectiveness of the proposed method. The results show that the new method performs well in identifying bearing fault frequency under strong background noise.

  16. 1H MR spectroscopy of human brain tumours: a practical approach

    International Nuclear Information System (INIS)

    Callot, Virginie; Galanaud, Damien; Le Fur, Yann; Confort-Gouny, Sylviane; Ranjeva, Jean-Philippe; Cozzone, Patrick J.

    2008-01-01

    Magnetic resonance spectroscopy (MRS) is proposed in addition to magnetic resonance imaging (MRI) to help in the characterization of brain tumours by detecting metabolic alterations that may be indicative of the tumour class. MRS can be routinely performed on clinical magnets, within a reasonable acquisition time and if performed under adequate conditions, MRS is reproducible and thus can be used for longitudinal follow-up of treatment. MRS can also be performed in clinical practice to guide the neurosurgeon into the most aggressive part of the lesions or to avoid unnecessary surgery, which may furthermore decrease the risk of surgical morbidity

  17. Surgical management of epithelial parotid tumours

    International Nuclear Information System (INIS)

    Obaid, M.A.; Yusuf, A.

    2004-01-01

    Objective: To describe the clinicopathological presentation and treatment options in epithelial parotid tumours with emphasis on surgery. Subjects and Methods: Epithelial parotid tumours diagnosed and operated by an ENT surgeon and a general surgeon in 10 years during their posting in different teaching hospitals were included in the study. Clinical presentation, preoperative investigations, operative procedure, histopathology report, postoperative complications and further management were recorded. The data was collected and reviewed from the records of all the patients maintained by the authors. Results: Fifty-two patients presented with parotid tumour. Average age was 38 years. Commonest presentation was painless lump over the parotid region (85%), pain (15%), facial palsy, and enlarged neck nodes. Majority of tumours were benign, only two were recurrent. Parotid pleomorphic Adenoma (PPA) was the commonest benign tumour, others being Warthin's tumour and monomorphic adenoma. Adenoid cystic carcinoma was the commonest malignant tumour 29% followed by mucoepidermoid carcinoma. Others were carcinoma in PPA squamous cell carcinoma, malignant mixed tumour, malignant Iymphoepithelioma and undifferentiated carcinoma. Superficial parotidectomy (SP) was the commonest operation performed in 69%. Other procedures were total conservative parotidectomy in 11%, total radical surgery in 9% and enucleation in only one patient earliest in the series. Neck node dissection was done in 2 patients. Except for one child, rest of the 13 patients received postoperative radiotherapy and one patient of Iymphoepithelioma received chemotherapy in addition. Commonest postoperative complication was temporary facial weakness in 35% (18/52). Permanent facial palsy occurred in 08 patients. Of these 07 had a malignant process and only one patient had excision biopsy. Conclusion: Benign and malignant epithelial parotid tumours can be diagnosed by there clinical presentation . supplemented with

  18. Cytochrome P450-mediated metabolism of tumour promoters modifies the inhibition of intercellular communication: a modified assay for tumour promotion

    DEFF Research Database (Denmark)

    Vang, Ole; Wallin, H.; Doehmer, J.

    1993-01-01

    The role of metabolism of tumour promoters on the inhibition of intercellular communication was investigated in a modified V79 metabolic cooperation system. V79 cells, which stably express different rat cytochrome P450 enzymes (CYP1A1, CYP1A2 or CYP2B1), were used in the metabolic cooperation assay...... B1 and 4-nitrobiphenyl, did not inhibit metabolic cooperation in either V79 cells expressing or cells not expressing cytochrome P450. We conclude that cytochrome P450-associated metabolism plays an important role in the inhibition of gap junctional intercellular communication of some tumour...... promoters. The modified metabolic cooperation assay presented here is valuable for detecting some inhibitory chemicals which have been 'false negative' in previous assays for gap junctional intercellular communication. The assay also discloses that cytochrome P450 metabolism alters intercellular...

  19. A forgotten facial nerve tumour: granular cell tumour of the parotid and its implications for treatment.

    Science.gov (United States)

    Lerut, B; Vosbeck, J; Linder, T E

    2011-04-01

    We present a rare case of a facial nerve granular cell tumour in the right parotid gland, in a 10-year-old boy. A parotid or neurogenic tumour was suspected, based on magnetic resonance imaging. Intra-operatively, strong adhesions to surrounding structures were found, and a midfacial nerve branch had to be sacrificed for complete tumour removal. Recent reports verify that granular cell tumours arise from Schwann cells of peripheral nerve branches. The rarity of this tumour within the parotid gland, its origin from peripheral nerves, its sometimes misleading imaging characteristics, and its rare presentation with facial weakness and pain all have considerable implications on the surgical strategy and pre-operative counselling. Fine needle aspiration cytology may confirm the neurogenic origin of this lesion. When resecting the tumour, the surgeon must anticipate strong adherence to the facial nerve and be prepared to graft, or sacrifice, certain branches of this nerve.

  20. Gene transfer preferentially selects MHC class I positive tumour cells and enhances tumour immunogenicity.

    Science.gov (United States)

    Hacker, Ulrich T; Schildhauer, Ines; Barroso, Margarita Céspedes; Kofler, David M; Gerner, Franz M; Mysliwietz, Josef; Buening, Hildegard; Hallek, Michael; King, Susan B S

    2006-05-01

    The modulated expression of MHC class I on tumour tissue is well documented. Although the effect of MHC class I expression on the tumorigenicity and immunogenicity of MHC class I negative tumour cell lines has been rigorously studied, less is known about the validity of gene transfer and selection in cell lines with a mixed MHC class I phenotype. To address this issue we identified a C26 cell subline that consists of distinct populations of MHC class I (H-2D/K) positive and negative cells. Transient transfection experiments using liposome-based transfer showed a lower transgene expression in MHC class I negative cells. In addition, MHC class I negative cells were more sensitive to antibiotic selection. This led to the generation of fully MHC class I positive cell lines. In contrast to C26 cells, all transfectants were rejected in vivo and induced protection against the parental tumour cells in rechallenge experiments. Tumour cell specificity of the immune response was demonstrated in in vitro cytokine secretion and cytotoxicity assays. Transfectants expressing CD40 ligand and hygromycin phosphotransferase were not more immunogenic than cells expressing hygromycin resistance alone. We suggest that the MHC class I positive phenotype of the C26 transfectants had a bearing on their immunogenicity, because selected MHC class I positive cells were more immunogenic than parental C26 cells and could induce specific anti-tumour immune responses. These data demonstrate that the generation of tumour cell transfectants can lead to the selection of subpopulations that show an altered phenotype compared to the parental cell line and display altered immunogenicity independent of selection marker genes or other immune modulatory genes. Our results show the importance of monitoring gene transfer in the whole tumour cell population, especially for the evaluation of in vivo therapies targeted to heterogeneous tumour cell populations.