WorldWideScience

Sample records for acoustic neuroma mimicking

  1. Acoustic Neuroma Association

    Science.gov (United States)

    ... EVENTS DONATE NEWS Home Learn Back Learn about acoustic neuroma AN Facts What is acoustic neuroma? Diagnosing ... Brain Freeze ? READ MORE Read More What is acoustic neuroma? Identifying an AN Learn More Get Info ...

  2. Acoustic Neuroma

    Science.gov (United States)

    An acoustic neuroma is a benign tumor that develops on the nerve that connects the ear to the brain. ... can press against the brain, becoming life-threatening. Acoustic neuroma can be difficult to diagnose, because the ...

  3. Facial neuroma masquerading as acoustic neuroma.

    Science.gov (United States)

    Sayegh, Eli T; Kaur, Gurvinder; Ivan, Michael E; Bloch, Orin; Cheung, Steven W; Parsa, Andrew T

    2014-10-01

    Facial nerve neuromas are rare benign tumors that may be initially misdiagnosed as acoustic neuromas when situated near the auditory apparatus. We describe a patient with a large cystic tumor with associated trigeminal, facial, audiovestibular, and brainstem dysfunction, which was suspicious for acoustic neuroma on preoperative neuroimaging. Intraoperative investigation revealed a facial nerve neuroma located in the cerebellopontine angle and internal acoustic canal. Gross total resection of the tumor via retrosigmoid craniotomy was curative. Transection of the facial nerve necessitated facial reanimation 4 months later via hypoglossal-facial cross-anastomosis. Clinicians should recognize the natural history, diagnostic approach, and management of this unusual and mimetic lesion. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. What Is an Acoustic Neuroma

    Science.gov (United States)

    ... CALENDAR DONATE NEWS Home Learn Back Learn about acoustic neuroma AN Facts What is acoustic neuroma? Diagnosing ... Italian Japanese Korean Portuguese Romanian Spanish What is Acoustic Neuroma? Each heading slides to reveal information. Important ...

  5. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Facts What is acoustic neuroma? Diagnosing Symptoms Side Effects Keywords Questions to ask Choosing a healthcare provider ... Surgery What is acoustic neuroma Diagnosing Symptoms Side effects Question To Ask Treatment Options Back Overview Observation ...

  6. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Facts What is acoustic neuroma? Diagnosing Symptoms Side Effects Keywords World Language Videos Questions to ask Choosing ... Surgery What is acoustic neuroma Diagnosing Symptoms Side effects Question To Ask Treatment Options Back Overview Observation ...

  7. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... 30041 770-205-8211 info@ANAUSA.org The world’s #1 acoustic neuroma resource Click to learn more... ... is acoustic neuroma? Diagnosing Symptoms Side Effects Keywords World Language Videos Questions to ask Choosing a healthcare ...

  8. [Treatment of giant acoustic neuromas].

    Science.gov (United States)

    Samprón, Nicolás; Altuna, Xabier; Armendáriz, Mikel; Urculo, Enrique

    2014-01-01

    To analyze the treatment modality and outcome of a series of patients with giant acoustic neuromas, a particular type of tumour characterised by their size (extracanalicular diameter of 4cm or more) and high morbidity and mortality. This was a retrospective unicentre study of patients with acoustic neuromas treated in a period of 12 years. In our institutional series of 108 acoustic neuromas operated on during that period, we found 13 (12%) cases of giant acoustic neuromas. We reviewed the available data of these cases, including presentation and several clinical, anatomical, and microsurgical aspects. All patients were operated on by the same neurosurgeon and senior author (EU) using the suboccipital retrosigmoid approach and complete microsurgical removal was achieved in 10 cases. In one case, near total removal was deliberately performed, in another case a CSF shunt was placed as the sole treatment measure, and in the remaining case no direct treatment was given. One patient died in the immediate postoperative period. One year after surgery, 4 patients showed facial nerve function of iii or more in the House-Brackman scale. The 4 most important prognostic characteristics of giant acoustic neuromas are size, adhesion to surrounding structures, consistency and vascularity. Only the first of these is evident in neuroimaging. Giant acoustic neuromas are characterised by high morbidity at presentation as well as after treatment. Nevertheless, the objective of complete microsurgical removal with preservation of cranial nerve function is attainable in some cases through the suboccipital retrosigmoid approach. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  9. Bilateral acoustic neuromas.

    Science.gov (United States)

    Anand, V T; Byrnes, D P; Walby, A P; Kerr, A G

    1993-10-01

    This article reviews 12 patients with bilateral acoustic neuromas. The sex incidence was equal and the mean age at diagnosis was 26.2 years. The family history was positive in nine of the patients. Five patients have had incomplete surgical removal of acoustic neuromas on both sides. Two of them are completely deaf and the other three have severe sensorineural hearing loss in one ear and no hearing in the other ear. In five patients the tumour on one side has been operated on and the other side is being observed with at least short-term preservation of good hearing. The remaining two patients died of intra-cranial complications, one of them post-operatively. Four patients developed facial palsy immediately following surgery and one developed facial weakness 6 months after surgery. Guidelines are discussed for the care of these patients including the timing of surgery and alternative treatment options (observation, radio-surgery and chemotherapy). This is essentially a group of young individuals who have had multiple operations for bilateral acoustic tumours and associated manifestations and for whom the disease and the sequelae of treatment can be tragic.

  10. Carcinomatous meningitis appearing as acoustic neuromas. Two cases

    International Nuclear Information System (INIS)

    Astner, S.T.; Nieder, C.; Grosu, A.L.; Stock, K.; Gaa, J.

    2007-01-01

    Background: For acoustic neuromas, stereotactic radiotherapy (radiosurgery or stereotactic fractionated radiotherapy) has been established as an important alternative to microsurgery. In most cases initial symptoms are slow progression of unilateral hearing loss, tinnitus or vertigo or acute hearing loss with vertigo. MRI scan shows a contrast-enhancing tumor within the inner auditory channel. If the patient undergoes primary radiotherapy, diagnosis is usually not verified histologically. Therefore, careful evaluation of the medical history is mandatory despite a typical appearance on the MRI scan. If medical history does not match with acoustic neuroma, further diagnostics are necessary to rule out infectious disease or carcinomatous meningitis. Case Report: Two patients with hearing loss, vertigo and the diagnosis of acoustic neuromas by MRI scan were referred for radiotherapy. In both cases the symptoms progressed very rapidly, not typical of acoustic neuromas, and in both patients repeated liquor puncture finally revealed carcinomatous meningitis. One patient died during therapy; in the second patient intrathecal chemotherapy and additional radiotherapy of the skull base led to partial remission continuing for several months. Conclusion: Before primary radiotherapy of small intrameatal lesions diagnosis must be reassessed carefully. This is especially true for bilateral lesions suspicious for acoustic neuromas and rapid progression and persistence of clinical symptoms where carcinomatous meningitis has to be taken into account. (orig.)

  11. Carcinomatous meningitis appearing as acoustic neuromas. Two cases

    Energy Technology Data Exchange (ETDEWEB)

    Astner, S T; Nieder, C; Grosu, A L [Technical Univ. of Munich (Germany). Dept. of Radiation Oncology; Stock, K [Technical Univ. of Munich (Germany). Dept. of Internal Medicine; Gaa, J [Technical Univ. of Munich (Germany). Dept. of Radiology

    2007-05-15

    Background: For acoustic neuromas, stereotactic radiotherapy (radiosurgery or stereotactic fractionated radiotherapy) has been established as an important alternative to microsurgery. In most cases initial symptoms are slow progression of unilateral hearing loss, tinnitus or vertigo or acute hearing loss with vertigo. MRI scan shows a contrast-enhancing tumor within the inner auditory channel. If the patient undergoes primary radiotherapy, diagnosis is usually not verified histologically. Therefore, careful evaluation of the medical history is mandatory despite a typical appearance on the MRI scan. If medical history does not match with acoustic neuroma, further diagnostics are necessary to rule out infectious disease or carcinomatous meningitis. Case Report: Two patients with hearing loss, vertigo and the diagnosis of acoustic neuromas by MRI scan were referred for radiotherapy. In both cases the symptoms progressed very rapidly, not typical of acoustic neuromas, and in both patients repeated liquor puncture finally revealed carcinomatous meningitis. One patient died during therapy; in the second patient intrathecal chemotherapy and additional radiotherapy of the skull base led to partial remission continuing for several months. Conclusion: Before primary radiotherapy of small intrameatal lesions diagnosis must be reassessed carefully. This is especially true for bilateral lesions suspicious for acoustic neuromas and rapid progression and persistence of clinical symptoms where carcinomatous meningitis has to be taken into account. (orig.)

  12. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... patient kit Treatment Options Overview Observation Radiation Surgery What is acoustic neuroma Diagnosing ... Back Community Patient Stories Share Your Story Video Stories Caregivers Milestones Gallery Submit Your Milestone Team ANA Volunteer ...

  13. Early diagnosis of acoustic neuroma by the vestibular test

    Energy Technology Data Exchange (ETDEWEB)

    Haid, T; Rettinger, G; Berg, M; Wigand, M E

    1981-11-01

    In a series of 390 cases with suspicion of acoustic neurinomas 78 such tumors could be diagnosed, including 12 early stage neurinomas. This relatively high detection quote of small neurinomas is due to a special diagnostical programme: Every patient with unilateral and sensoneural hearingloss, independent of vertigo anamnesis or of the result of X-rays must be further examined by a vestibular test. All 78 patients with acoustic neuroma had pathological vestibular findings. The positional test turned out to be the most sensitive examination in the early diagnosis of acoustic neuromas and yields a still higher incidence than the thermic test: 95% of the patients with a neuroma showed pathological findings in the positional test. Every patient suffering from an unidentified unilateral and sensoneural hearingloss combined with a pathological result in the positional test must be further checked by a cisternomeatography or computerized tomography using airinsufflation. Every fifth of these patients showed typical signs of an acoustic neuroma in the neuroradiological tests. 68 neuromas are operated today and verfied histologically, 10 patients are still waiting for surgical treatment.

  14. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Spanish Washington Support Group Leslie of Stone Mountain, ... Providers Acoustic Neuroma Association Donate Now Newly Diagnosed What is AN? Request a Patient Kit Treatment Options Get Support Find a Provider Discussion Forum ...

  15. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Learn more about ANA About ANA Mission, Vision & Values Shop ANA Leadership & Staff Annual Reports Acoustic Neuroma ... 8211 info@ANAUSA.org About ANA Mission, Vision & Values Leadership & Staff Annual Reports Shop ANA Home Learn ...

  16. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... ANA About ANA Mission, Vision & Values Shop ANA Leadership & Staff Annual Reports Acoustic Neuroma Association 600 Peachtree ... info@ANAUSA.org About ANA Mission, Vision & Values Leadership & Staff Annual Reports Shop ANA Home Learn Educational ...

  17. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... a healthcare provider Request a patient kit Treatment Options Overview Observation Radiation Surgery What is acoustic neuroma Diagnosing Symptoms Side effects Question To Ask Treatment Options Back Overview Observation Radiation Surgery Choosing a healthcare ...

  18. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... a patient kit Treatment Options Overview Observation Radiation Surgery What is acoustic neuroma Diagnosing Symptoms Side effects ... To Ask Treatment Options Back Overview Observation Radiation Surgery Choosing a healthcare provider Request a patient kit ...

  19. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Connections Overview Find a Meeting Host a Meeting Volunteer Become a Volunteer Opportunities Support Overview Patient Events ... ANA About ANA Mission, Vision & Values Shop ANA Leadership & Staff Annual Reports Acoustic Neuroma Association 600 Peachtree ...

  20. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Choosing a healthcare provider Request a patient kit Treatment Options Overview Observation Radiation Surgery What is acoustic neuroma Diagnosing Symptoms Side effects Question To Ask Treatment Options Back Overview Observation Radiation Surgery Choosing a ...

  1. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... 1 acoustic neuroma resource Click to learn more... LOGIN CALENDAR DONATE NEWS Home Learn Back Learn about ... Webinar Library Newsletter Library Patient Info Booklets Member Login Research ANA Survey/Registry AN Research Patient Registry ...

  2. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Mission, Vision & Values Shop ANA Leadership & Staff Annual Reports Acoustic Neuroma Association 600 Peachtree Parkway Suite 108 ... About ANA Mission, Vision & Values Leadership & Staff Annual Reports Shop ANA Home Learn Educational Video English English ...

  3. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... About ANA Mission, Vision & Values Shop ANA Leadership & Staff Annual Reports Acoustic Neuroma Association 600 Peachtree Parkway ... ANAUSA.org About ANA Mission, Vision & Values Leadership & Staff Annual Reports Shop ANA Home Learn Educational Video ...

  4. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Click to learn more... LOGIN CALENDAR DONATE NEWS Home Learn Back Learn about acoustic neuroma AN Facts ... Vision & Values Leadership & Staff Annual Reports Shop ANA Home Learn Educational Video English English Arabic Catalan Chinese ( ...

  5. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Cumming, GA 30041 770-205-8211 info@ANAUSA.org The world’s #1 acoustic neuroma resource Click to ... Cumming, GA 30041 770-205-8211 info@ANAUSA.org About ANA Mission, Vision & Values Leadership & Staff Annual ...

  6. Early diagnosis of acoustic neuroma by quantitative neurootological and neuroradiological tests

    Energy Technology Data Exchange (ETDEWEB)

    Haid, C T

    1983-02-01

    Every patient with unilateral and sensoneural loss of hearing, independent of vertigo anamnesis or X-rays must be further examined by a vestibular test. Between 1974 and 1980, 80 acoustic neuromas could be diagnosed, including 12 early stage neuromas. This relatively high detection quote of small neuromas is due to a special diagnostical program: All 80 patients with acoustic neuroma had a pathological vestibular result. The positional test turned out to be the most sensitive examination in the early diagnosis of acoustic neuromas and yields a still higher incidence than the caloric test: 95% of the patients with a neurinoma showed a pathological result in the positional test. So every patient suffering from an unidentified unilateral and sensoneural hearing loss combined with a pathological result in the positional test must be further examined by a cisternomeatography or computerized tomography (using air-insufflation). Every fifth of these patients showed unique hints of an acoustic neuroma in the neuroradiological test.

  7. Organising haematoma mimicking tumour on MRI following resection of acoustic neuroma

    International Nuclear Information System (INIS)

    Higgins, J.N.P.; Pigeon, C.N.; Moseley, I.F.

    1995-01-01

    We describe a 26-year-old woman in whom an enhancing, intradural extramedullary mass was found at the craniocervical junction on MRI 3 years after resection of a large acoustic neuroma. The radiological appearances suggested a new tumour, raising the possibility of neurofibromatosis 2, provoking a review of family members in an attempt to confirm the diagnosis, as well as further surgery. Histology of the lesion revealed an organising haematoma, with no evidence of malignancy. The imaging features can be explained by the process by which blood clot in the subarachnoid space is resorbed. Caution is advised in interpreting CT or MRI after neurosurgery. (orig.)

  8. Four cases of acoustic neuromas with normal hearing.

    Science.gov (United States)

    Valente, M; Peterein, J; Goebel, J; Neely, J G

    1995-05-01

    In 95 percent of the cases, patients with acoustic neuromas will have some magnitude of hearing loss in the affected ear. This paper reports on four patients who had acoustic neuromas and normal hearing. Results from the case history, audiometric evaluation, auditory brainstem response (ABR), electroneurography (ENOG), and vestibular evaluation are reported for each patient. For all patients, the presence of unilateral tinnitus was the most common complaint. Audiologically, elevated or absent acoustic reflex thresholds and abnormal ABR findings were the most powerful diagnostic tools.

  9. VESTIBULAR SCHWANNOMA (ACOUSTIC NEUROMA) MIMICKING TEMPOROMANDIBULAR DISORDERS: A CASE REPORT

    Science.gov (United States)

    Bisi, Maurício A.; Selaimen, Caio M. P.; Chaves, Karen D.; Bisi, Melissa C.; Grossi, Márcio L.

    2006-01-01

    Approximately 6 to 16% of patients with trigeminal neuralgia symptoms present intracranial tumors, the most common being the vestibular schwannoma (acoustic neuroma). Some symptoms reported by patients include hearing loss, tinnitus, headaches, vertigo and trigeminal disturbances. An increased muscle response in the surrounding head and neck musculature may also be observed, which mimics signs and symptoms of temporomandibular disorders. In these cases, magnetic resonance imaging (MRI) has proved to be a useful tool in tumor diagnosis. The differential diagnosis between myofascial and neuralgic pain is important, as both may present similar characteristics, while being of different origin, and demanding special treatment approaches. The purpose of this paper is to demonstrate the relationship among trigeminal neuralgia symptoms, intracranial tumors and temporomandibular dysfunction by presenting a clinical case. PMID:19089251

  10. The Top 50 Most-Cited Articles on Acoustic Neuroma.

    Science.gov (United States)

    Alfaifi, Abrar; AlMutairi, Othman; Allhaidan, Maha; Alsaleh, Saad; Ajlan, Abdulrazag

    2018-03-01

    Acoustic neuroma is the most common extra-axial primary cerebellopontine angle tumor in adults. A plethora of studies have been published on acoustic neuroma, but none of the previous works have highlighted the most influential articles. Our objective was to perform a bibliometric analysis of the 50 most-cited articles on acoustic neuroma. We performed a title-specific search on the Scopus database using the following search terms: "acoustic neuroma," "vestibular schwannoma," and "cerebellopontine angle." We recorded the 50 most-cited articles and reviewed them. The 50 most-cited articles had an average of 175 citations per article. All articles were published between 1980 and 2006, with 1997 the most prolific year, when 7 articles were published. The journals Neurosurgery and Laryngoscope published 10 and 8 of these articles, respectively. The most common study categories were nonsurgical management (17/50) and surgical management (13/50). Studies were predominantly published by otolaryngologists (22/50) and neurosurgeons (14/50). Douglas Kondziolka was the author with the highest number of contributions, with 7 publications. The majority of the articles were produced in the United States (64%). Identifying articles on acoustic neuroma with the most impact provides an important overview of the historical development of treatment methods and publication trends related to this condition. A finalized, comprehensive list of the most important works represents an excellent tool that can serve as a guide for evidence-based clinical practice. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Stereotactic radiosurgery for acoustic neuroma: a Canadian perspective

    International Nuclear Information System (INIS)

    Ross, I.B.; Tator, C.H.

    1998-01-01

    Stereotactically delivered radiation is now an accepted treatment for patients with acoustic neuroma. In some cases, patient preference may be the reason for its selection, while in others neurosurgeons may select it for patients who are elderly or have significant risk factors for conventional surgery. The majority of patients with acoustic neuroma treatment with stereotactic radiosurgery have been treated with the Gamma Knife, with follow ups of over 25 years in some instances. Other radiosurgical modalities utilizing the linear accelerator have been developed and appear promising, but there is no long-term: follow up. Canada does not possess a Gamma Knife facility, and its government-funded hospital and medical insurance agencies have made it difficult for patients to obtain reimbursement for Gamma Knife treatments in other countries. We review the literature to date on the various forms of radiation treatment for acoustic neuroma and discuss the current issues facing physicians and patients in Canada who wish to obtain their treatment of choice. (author)

  12. Summary and consensus in 7th International Conference on acoustic neuroma: An update for the management of sporadic acoustic neuromas

    Directory of Open Access Journals (Sweden)

    Hao Wu

    2016-12-01

    Full Text Available Sporadic vestibular schwannoma (acoustic neuroma is a benign tumor arising from cochleovestibular nerve. Nowadays, various specialties and medical centers are treating this disease, and the multidisciplinary collaboration is the trend. In an effort to promote a uniform standard for reporting clinical results, even for treatment indications, the mainly controversies were posed and discussed during the 7th International Conference on acoustic neuroma, and the agreement was summarized by the Committee of this conference. The main symptoms grading and tumor stage should note its name of classification for making them comparable. The goal of the modern managements for vestibular schwannoma is to improve the quality of life with lower mortality, lower morbidity and better neurological function preservation. The experience of surgical team and their preference might be a major factor for the outcome. Because of lacking of long-term follow-up large data after radiotherapy, and with the development of microsurgery, radiotherapy is now less recommended except for recurrent cases or elderly patients. Keywords: Sporadic acoustic neuroma, Vestibular schwannoma, Management, Symptoms grading, Tumor stage, Microsurgery, Radiotherapy

  13. ''Dural tail'' adjacent to acoustic neuroma on MRI: a case report

    International Nuclear Information System (INIS)

    Lunardi, P.; Mastronardi, L.; Nardacci, B.; Acqui, M.; Fortuna, A.

    1993-01-01

    A 'dural tail' on Gd-DTPA-enhanced MRI has been often observed adjacent to meningiomas and considered to be useful in distinguishing meningioma of the cerebellopontine angle from acoustic neuroma. However, demonstration of a dural tail adjacent to an acoustic neuroma indicates that this sign is not specific. (orig.)

  14. Hydroxyapatite cement cranioplasty in translabyrinthine acoustic neuroma surgery.

    Science.gov (United States)

    Arriaga, Moisês A; Chen, Douglas A

    2002-05-01

    Hydroxyapatite cement cranioplasty (HAC) after translabyrinthine resection of acoustic neuroma is a promising new technique for wound reconstruction. This study reviews the efficacy of HAC for the prevention of cerebrospinal fluid (CSF) leakage and the long-term wound outcomes of HAC versus abdominal fat graft (AFG) reconstruction. This retrospective study of l08 consecutive acoustic neuromas operated on by Pittsburgh Ear Associates uses chart review, telephone interview, and mail questionnaire data. Fifty-four patients received AFG dural repair, and 54 patients received HAC. Seven AFG patients (12.5%) had CSF leaks versus 2 (3.7%) of the overall group of 54 HAC patients. However, none (0%) of the 47 HAC patients had CSF leakage with current HAC techniques. HAC also produced significantly less postauricular wound depression and superior cosmetic results in comparison with AFG. Although HAC patients experienced less postoperative discomfort, wound complications requiring medical or surgical intervention were extremely uncommon in both groups. HAC offers significant CSF leakage control and long-term cosmetic and comfort advantages over AFG alone. We recommend HAC as the standard closure technique for translabyrinthine acoustic neuroma surgery.

  15. Repeat Stereotactic Radiosurgery for Acoustic Neuromas

    International Nuclear Information System (INIS)

    Kano, Hideyuki; Kondziolka, Douglas; Niranjan, Ajay M.Ch.; Flannery, Thomas J.; Flickinger, John C.; Lunsford, L. Dade

    2010-01-01

    Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second SRS. The median interval between initial SRS and repeat SRS was 63 months (range, 25-169 months). Results: At a median follow-up of 29 months after the second SRS (range, 13-71 months), tumor control or regression was achieved in all 6 patients. No patient developed symptomatic adverse radiation effects or new neurological symptoms after the second SRS. Conclusions: With this limited experience, we found that repeat SRS for a persistently enlarging acoustic neuroma can be performed safely and effectively.

  16. Dose and diameter relationships for facial, trigeminal, and acoustic neuropathies following acoustic neuroma radiosurgery

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Lunsford, L. Dade

    1996-01-01

    Purpose and objective: To define the relationships between dose and tumor diameter for the risks of developing trigeminal, facial, and acoustic neuropathies after acoustic neuroma radiosurgery, a large single-institution experience was analyzed. Materials and methods: Two hundred and thirty-eight patients with unilateral acoustic neuromas who underwent Gamma knife radiosurgery between 1987-1994 with 6-91 months of follow-up (median 30 months) were studied. Minimum tumor doses were 12-20 Gy (median 15 Gy). Transverse tumor diameter varied from 0.3-5.5 cm (median 2.1 cm). The relationships of dose and diameter to the development of cranial neuropathies were delineated by multivariate logistic regression. Results: The development of post-radiosurgery neuropathies affecting cranial nerves V, VII, and VIII were correlated with minimum tumor dose and transverse tumor diameter (P min for VIII where P=0.10). A comparison of the dose-diameter response curves showed the acoustic nerve to be the most sensitive to doses of 12-16 Gy and the facial nerve to be the least sensitive. Conclusion: The risks of developing trigeminal, facial, and acoustic neuropathies following acoustic neuroma radiosurgery can be predicted from the transverse tumor diameter and the minimum tumor dose using models constructed from data presently available

  17. Resection planning for robotic acoustic neuroma surgery

    Science.gov (United States)

    McBrayer, Kepra L.; Wanna, George B.; Dawant, Benoit M.; Balachandran, Ramya; Labadie, Robert F.; Noble, Jack H.

    2016-03-01

    Acoustic neuroma surgery is a procedure in which a benign mass is removed from the Internal Auditory Canal (IAC). Currently this surgical procedure requires manual drilling of the temporal bone followed by exposure and removal of the acoustic neuroma. This procedure is physically and mentally taxing to the surgeon. Our group is working to develop an Acoustic Neuroma Surgery Robot (ANSR) to perform the initial drilling procedure. Planning the ANSR's drilling region using pre-operative CT requires expertise and around 35 minutes' time. We propose an approach for automatically producing a resection plan for the ANSR that would avoid damage to sensitive ear structures and require minimal editing by the surgeon. We first compute an atlas-based segmentation of the mastoid section of the temporal bone, refine it based on the position of anatomical landmarks, and apply a safety margin to the result to produce the automatic resection plan. In experiments with CTs from 9 subjects, our automated process resulted in a resection plan that was verified to be safe in every case. Approximately 2 minutes were required in each case for the surgeon to verify and edit the plan to permit functional access to the IAC. We measured a mean Dice coefficient of 0.99 and surface error of 0.08 mm between the final and automatically proposed plans. These preliminary results indicate that our approach is a viable method for resection planning for the ANSR and drastically reduces the surgeon's planning effort.

  18. Long-term mobile phone use and acoustic neuroma risk.

    Science.gov (United States)

    Pettersson, David; Mathiesen, Tiit; Prochazka, Michaela; Bergenheim, Tommy; Florentzson, Rut; Harder, Henrik; Nyberg, Gunnar; Siesjö, Peter; Feychting, Maria

    2014-03-01

    There is concern about potential effects of radiofrequency fields generated by mobile phones on cancer risk. Most previous studies have found no association between mobile phone use and acoustic neuroma, although information about long-term use is limited. We conducted a population-based, nation-wide, case-control study of acoustic neuroma in Sweden. Eligible cases were persons aged 20 to 69 years, who were diagnosed between 2002 and 2007. Controls were randomly selected from the population registry, matched on age, sex, and residential area. Postal questionnaires were completed by 451 cases (83%) and 710 controls (65%). Ever having used mobile phones regularly (defined as weekly use for at least 6 months) was associated with an odds ratio (OR) of 1.18 (95% confidence interval = 0.88 to 1.59). The association was weaker for the longest induction time (≥10 years) (1.11 [0.76 to 1.61]) and for regular use on the tumor side (0.98 [0.68 to 1.43]). The OR for the highest quartile of cumulative calling time (≥680 hours) was 1.46 (0.98 to 2.17). Restricting analyses to histologically confirmed cases reduced all ORs; the OR for ≥680 hours was 1.14 (0.63 to 2.07). A similar pattern was seen for cordless land-line phones, although with slightly higher ORs. Analyses of the complete history of laterality of mobile phone revealed considerable bias in laterality analyses. The findings do not support the hypothesis that long-term mobile phone use increases the risk of acoustic neuroma. The study suggests that phone use might increase the likelihood that an acoustic neuroma case is detected and that there could be bias in the laterality analyses performed in previous studies.

  19. Conventionally fractionated stereotactic radiotherapy (FSRT) for acoustic neuromas

    International Nuclear Information System (INIS)

    Fuss, Martin; Debus, Juergen; Lohr, Frank; Huber, Peter; Rhein, Bernhard; Engenhart-Cabillic, Rita; Wannenmacher, Michael

    2000-01-01

    Purpose: Analysis of local tumor control and functional outcome following conventionally fractionated stereotactic radiotherapy (FSRT) for acoustic neuromas. Patients and Methods: From 11/1989 to 9/1999 51 patients with acoustic neuromas have been treated by FSRT. Mean total dose was 57.6 ± 2.5 Gy. Forty-two patients have been followed for at least 12 months and were subject of an outcome analysis. Mean follow-up was 42 months. We analyzed local control, hearing preservation, and facial and trigeminal nerve functional preservation. We evaluated influences of tumor size, age, and association with neurofibromatosis Type 2 (NF2) on outcome and treatment related toxicity. Results: Actuarial 2- and 5-year tumor control rates were 100% and 97.7%, respectively. Actuarial useful hearing preservation rate was 85% at 2 and 5 years. New hearing loss was diagnosed in 4 NF2 patients. Pretreatment normal facial nerve function was preserved in all cases. Two cases of new or impaired trigeminal nerve dysesthesia required medication. No other cranial nerve deficit was observed. In Patients without NF2 tumor size or age had no influence on tumor control and cranial nerve toxicity. Diagnosis of NF2 was associated with higher risk of hearing impairment (p 0.0002), the hearing preservation rate in this subgroup was 60%. Conclusion: FSRT has been shown to be an effective means of local tumor control. Excellent hearing preservation rates and 5th and 7th nerve functional preservation rates were achieved. The results support the conclusion that FSRT can be recommended to patients with acoustic neuromas where special attention has to be taken to preserve useful hearing and normal cranial nerve function. For NF2 patients, FSRT may be the treatment of choice with superior functional outcome compared to treatment alternatives.

  20. [Clinical and radiological evolution of a group of untreated acoustic neuromas].

    Science.gov (United States)

    Escorihuela-García, Vicente; Llópez-Carratalá, Ignacio; Orts-Alborch, Miguel; Marco-Algarra, Jaime

    2014-01-01

    The acoustic neuroma is a benign tumour that originates in the vestibular branch of the eighth cranial nerve. The main treatment is surgery, but many authors suggest that with elderly patients or in small neuromas we can opt for watchful waiting. This was a retrospective study from 2007 to 2013 that included 27 patients diagnosed of acoustic neuroma that had not been treated due to the size of the tumour, age and comorbidities, or by patient choice. We evaluated overall condition, hearing thresholds, degree of canal paresis and central disorders. After 6 years of follow up, clinical manifestations of 18 patients remained unchanged, 5 patients underwent hearing loss and developed tinnitus, 2 cases had more intense tinnitus and 2 cases had dizziness. The radiological controls by magnetic resonance imaging showed that the initial maximum diameters (5-16mm) increased by 1.7mm on average, with annual growth rates below 0.5mm. In selected cases, such as for small neuromas and in elderly patients, the conservative option of close monitoring with magnetic resonance imaging is an important alternative given that, in our cases, clinical features and radiological image did not suffer major changes. If there were any such changes, therapeutic options could be proposed. Copyright © 2013 Elsevier España, S.L. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  1. MR of acoustic neuromas

    International Nuclear Information System (INIS)

    Suzuki, Masayuki; Takashima, Tsutomu; Kadoya, Masumi; Takahashi, Shiroh; Miyayama, Shiroh; Taira, Sakae; Kashihara, Kengo; Yamashima, Tetsumori; Itoh, Haruhide

    1989-01-01

    In this report, the relationship of acoustic neuromas to the adjacent cranial nerves is discussed. On T 1 -weighted images, the trigeminal nerve was detected in all 13 cases. Mild to marked compression of these nerves by the tumors was observed in eight cases. The extent of compression did not always correspond to the clinical symptoms. In four cases with a maximum tumor diameter of 2 cm or less, the 7th and 8th cranial nerves were identified. There was no facial palsy in these patients. Two patients with a tumor diameter of more than 2 cm also had no facial palsy. All patients, including those with small tumors, complained of hearing loss and/or tinnitus. While MR imaging has some limitations, it is an effective imaging modality for showing the relationship between tumors and nerves. (author)

  2. The treatment for acoustic neuromas. Indication and results of gamma knife radiosurgery and surgery

    International Nuclear Information System (INIS)

    Iwai, Yoshiyasu; Yamanaka, Kazuhiro; Uyama, Taichi; Morikawa, Toshie; Honda, Yuji; Matsusaka, Yasuhiro; Komiyama, Masaki; Yasui, Toshihiro

    2004-01-01

    We evaluated the treatment results of acoustic neuromas in the era of radiosurgery. We treated acoustic neuromas using the following strategy. Small to medium size tumors (below 3 cm) were treated by gamma knife radiosurgery and large tumors (above 3 cm) were treated using a combination of surgery and radiosurgery. Using gamma knife radiosurgery we were able to achieve 96.4% of clinical tumor growth control with 0.7% incidence of trigeminal neuropathy (without new facial neuropathy). We used low dose radiosurgery (average tumor marginal dose 11.8 Gy) with a follow-up of an average of 54 months. For the 17 patients with large tumors treated by the combination of surgery and radiosurgery who could be followed up for over 24 months after radiosurgery, we were able to preserve normal facial function (House-Brackmann grade I-II) in 70.6% of the patients after subtotal removal. High clinical tumor growth control for residual tumor was achieved in 94.1% of subjects with an average of 40 months follow-up. By using this strategy, the treatment outcome for acoustic neuroma is improved from the standpoint of functional outcome and maintaining the patient's quality of life. (author)

  3. Calculating the tumor volume of acoustic neuromas: comparison of ABC/2 formula with planimetry method.

    Science.gov (United States)

    Yu, Yi-Lin; Lee, Meei-Shyuan; Juan, Chun-Jung; Hueng, Dueng-Yuan

    2013-08-01

    The ABC/2 equation is commonly applied to measure the volume of intracranial hematoma. However, the precision of ABC/2 equation in estimating the tumor volume of acoustic neuromas is less addressed. The study is to evaluate the accuracy of the ABC/2 formula by comparing with planimetry method for estimating the tumor volumes. Thirty-two patients diagnosed with acoustic neuroma received contrast-enhanced magnetic resonance imaging of brain were recruited. The volume was calculated by the ABC/2 equation and planimetry method (defined as exact volume) at the same time. The 32 patients were divided into three groups by tumor volume to avoid volume-dependent overestimation (6 ml). The tumor volume by ABC/2 method was highly correlated to that calculated by planimetry method using linear regression analysis (R2=0.985). Pearson correlation coefficient (r=0.993, pABC/2 formula is an easy method in estimating the tumor volume of acoustic neuromas that is not inferior to planimetry method. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Impact of facial paralysis on patients with acoustic neuroma.

    Science.gov (United States)

    Cross, T; Sheard, C E; Garrud, P; Nikolopoulos, T P; O'Donoghue, G M

    2000-09-01

    To assess the psychological distress, the ways of coping with that stress, and the self-esteem of patients with facial paralysis after acoustic neuroma surgery. Possible predictors and associations between these measures were also explored. Four validated questionnaires were completed by patients with facial paralysis after acoustic neuroma surgery: 1) the Derriford Appearance Scale (DAS) to measure psychological distress, 2) the COPE questionnaire to measure how patients cope with facial paralysis, 3) the Personal Report questionnaire to measure the self-esteem of patients, and 4) the Facial Paralysis Questionnaire (FPQ) to measure the severity of facial paralysis. One hundred three patients with facial paralysis after surgical removal of acoustic tumors. Distress spanned a wide range in these patients. There was no statistically significant association between the level of distress and the grade of facial paralysis or between time since operation and levels of distress. Women had higher levels of distress (P = .02) and a significant negative correlation was found between levels of distress and age (r = -0.28, P = .005). High levels of distress were associated with low levels of self-esteem, as shown by the significant negative correlation between level of distress and self-esteem (r = -0.59, P = .01). A significant correlation between distress and maladaptive coping (r = 0.31, P = .002) was also found. Stepwise multiple regression of the distress scores revealed that self-esteem was the most important contributing factor (standardized coefficient beta -0.60, P = .0001), followed by age (beta -0.24, P = .006) and sex (beta -0.21, P = .04). This model explained 44% of the distress variance. Clinicians must be aware of the distress felt by some patients experiencing facial palsy after acoustic neuroma surgery and that the level of distress may not be related to the clinical grade of the facial nerve paralysis. People with low self-esteem, young people, and women

  5. Stereotactic radiosurgery using the gamma knife for acoustic neuromas

    International Nuclear Information System (INIS)

    Foote, Robert L.; Coffey, Robert J.; Swanson, Jerry W.; Harner, Stephen G.; Beatty, Charles W.; Kline, Robert W.; Stevens, Lorna N.; Hu, Theresa C.

    1995-01-01

    Purpose: To assess the efficacy and toxicity of stereotactic radiosurgery using the gamma knife for acoustic neuromas. Methods and Materials: Between January 1990 and January 1993, 36 patients with acoustic neuromas were treated with stereotactic radiosurgery using the gamma knife. The median maximum tumor diameter was 21 mm (range: 6-32 mm). Tumor volumes encompassed within the prescribed isodose line varied from 266 to 8,667 mm 3 (median: 3,135 mm 3 ). Tumors ≤ 20 mm in maximum diameter received a dose of 20 Gy to the margin, tumors between 21 and 30 mm received 18 Gy, and tumors > 30 mm received 16 Gy. The dose was prescribed to the 50% isodose line in 31 patients and to the 45%, 55%, 60%, 70%, and 80% isodose line in one patient each. The median number of isocenters per tumor was 5 (range: 1-12). Results: At a median follow-up of 16 months (range: 2.5-36 months), all patients were alive. Thirty-five patients had follow-up imaging studies. Nine tumors (26%) were smaller, and 26 tumors (74%) were unchanged. No tumor had progressed. The 1- and 2-year actuarial incidences of facial neuropathy were 52.2% and 66.5%, respectively. The 1- and 2-year actuarial incidences of trigeminal neuropathy were 33.7% and 58.9%, respectively. The 1- and 2-year actuarial incidence of facial or trigeminal neuropathy (or both) was 60.8% and 81.7%, respectively. Multivariate analysis revealed that the following were associated with the time of onset or worsening of facial weakness or trigeminal neuropathy: (a) patients five isocenters. The 1- and 2-year actuarial rates of preservation of useful hearing (Gardner-Robertson class I or II) were 100% and 41.7% ± 17.3, respectively. Conclusion: Stereotactic radiosurgery using the gamma knife provides short-term control of acoustic neuromas when a dose of 16 to 20 Gy to the tumor margin is used. Preservation of useful hearing can be accomplished in a significant proportion of patients

  6. Calculation of cranial nerve complication probability for acoustic neuroma radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Foote, Kelly D.; Friedman, William A.; Bova, Francis J.

    2000-01-01

    Purpose: Estimations of complications from stereotactic radiosurgery usually rely simply on dose-volume or dose-diameter isoeffect curves. Due to the sparse clinical data available, these curves have typically not considered the target location in the brain, target histology, or treatment plan conformality as parameters in the calculation. In this study, a predictive model was generated to estimate the probability of cranial neuropathies as a result of acoustic schwannoma radiosurgery. Methods and Materials: The dose-volume histogram reduction scheme was used to calculate the normal tissue complication probability (NTCP) from brainstem dose-volume histograms. The model's fitting parameters were optimized to provide the best fit to the observed complication data for acoustic neuroma patients treated with stereotactic radiosurgery at the University of Florida. The calculation was then applied to the remainder of the patients in the database. Results: The best fit to our clinical data was obtained using n = 0.04, m = 0.15, and no. alphano. /no. betano. = 2.1 Gy -1 . Although the fitting parameter m is relatively consistent with ranges found in the literature, both the volume parameter, n, and no. alphano. /no. betano. are much smaller than the values quoted in the literature. The fit to our clinical data indicates that brainstem, or possibly a specific portion of the brainstem, is more radiosensitive than the parameters in the literature indicate, and that there is very little volume effect; in other words, irradiation of a small fraction of the brainstem yields NTCPs that are nearly as high as those calculated for entire volume irradiation. These new fitting parameters are specific to acoustic neuroma radiosurgery, and the small volume effect that we observe may be an artifact of the fixed relationship of acoustic tumors to specific regions of the brainstem. Applying the model to our patient database, we calculate an average NTCP of 7.2% for patients who had no

  7. Fractionated stereotactic radiotherapy for acoustic neuromas: A prospective monocenter study of about 158 cases

    International Nuclear Information System (INIS)

    Litre, Fabien; Rousseaux, Pascal; Jovenin, Nicolas; Bazin, Arnaud; Peruzzi, Philippe; Wdowczyk, Didier; Colin, Philippe

    2013-01-01

    Purpose: To evaluate long-term outcomes and efficacy of fractionated stereotactic radiotherapy in the treatment of acoustic neuromas. Material and methods: Between January 1996 and December 2009, 158 acoustic neuromas were treated by FSR in 155 patients. They received a dose of 50.4 Gy, with a safety margin of 1–2 mm with a median tumor volume at 2.45 mL (range: 0.17–12.5 mL) and a median follow-up duration at 60 months (range: 24–192). Results: FSR was well tolerated in all patients with mild sequelae consisting in radiation-induced trigeminal nerve impairments (3.2%), Grade 2 facial neuropathies (2.5%), new or aggravated tinnitus (2.1%) and VP shunting (2.5%). The treatment failed in four patients (2.5%) who had subsequent surgery respectively at 20, 38, 45 and 84 months post-FSR. The local tumor control rates were respectively 99.3%, 97.5% and 95.2% at 3, 5 and >7-year of follow-up. For initial Gardner–Robertson Grade 1 and 2 ANs, the preservation of useful hearing was possible in 54% of the cases; only Grade 1 ANs had stabilized during the course of the follow-up with 71% >7 years. However, hearing preservation was not correlated to the initial Koos Stage and to the radiation dose delivered to the cochlea. Tinnitus (70%), vertigo (59%), imbalance (46%) and ear mastoid pain (43%) had greatly improved post-FRS in most patients. Tumor control, hearing preservation and FRS toxicity were quite similar in patients with NF2, cystic acoustic neuroma, prior surgical resection and Koos Stage 4 AN. No secondary tumors were observed. Conclusion: FSR is a safe and effective therapeutic for acoustic neuromas and could be an alternative to microsurgery. Compared to radiosurgery, there are no contraindications for fractioned doses of stereotactic radiotherapy especially for Stage-4 tumors and patients at high risk of hearing loss

  8. Fractionated stereotactic radiotherapy for acoustic neuromas: A prospective monocenter study of about 158 cases

    Energy Technology Data Exchange (ETDEWEB)

    Litre, Fabien [Hôpital Maison Blanche, Reims Cedex (France); Rousseaux, Pascal [Hôpital Maison Blanche, Reims Cedex (France); Jovenin, Nicolas [Institut Jean Godinot, Reims Cedex (France); Bazin, Arnaud; Peruzzi, Philippe [Hôpital Maison Blanche, Reims Cedex (France); Wdowczyk, Didier; Colin, Philippe [Institut du Cancer Reims Courlancy, Reims (France)

    2013-02-15

    Purpose: To evaluate long-term outcomes and efficacy of fractionated stereotactic radiotherapy in the treatment of acoustic neuromas. Material and methods: Between January 1996 and December 2009, 158 acoustic neuromas were treated by FSR in 155 patients. They received a dose of 50.4 Gy, with a safety margin of 1–2 mm with a median tumor volume at 2.45 mL (range: 0.17–12.5 mL) and a median follow-up duration at 60 months (range: 24–192). Results: FSR was well tolerated in all patients with mild sequelae consisting in radiation-induced trigeminal nerve impairments (3.2%), Grade 2 facial neuropathies (2.5%), new or aggravated tinnitus (2.1%) and VP shunting (2.5%). The treatment failed in four patients (2.5%) who had subsequent surgery respectively at 20, 38, 45 and 84 months post-FSR. The local tumor control rates were respectively 99.3%, 97.5% and 95.2% at 3, 5 and >7-year of follow-up. For initial Gardner–Robertson Grade 1 and 2 ANs, the preservation of useful hearing was possible in 54% of the cases; only Grade 1 ANs had stabilized during the course of the follow-up with 71% >7 years. However, hearing preservation was not correlated to the initial Koos Stage and to the radiation dose delivered to the cochlea. Tinnitus (70%), vertigo (59%), imbalance (46%) and ear mastoid pain (43%) had greatly improved post-FRS in most patients. Tumor control, hearing preservation and FRS toxicity were quite similar in patients with NF2, cystic acoustic neuroma, prior surgical resection and Koos Stage 4 AN. No secondary tumors were observed. Conclusion: FSR is a safe and effective therapeutic for acoustic neuromas and could be an alternative to microsurgery. Compared to radiosurgery, there are no contraindications for fractioned doses of stereotactic radiotherapy especially for Stage-4 tumors and patients at high risk of hearing loss.

  9. Enhanced intrinsic radiosensitivity after treatment with stereotactic radiosurgery for an acoustic neuroma

    International Nuclear Information System (INIS)

    Adams, Gerard; Martin, Olga A.; Roos, Daniel E.; Lobachevsky, Pavel N.; Potter, Andrew E.; Zacest, Andrew C.; Bezak, Eva; Bonner, William M.; Martin, Roger F.; Leong, Trevor

    2012-01-01

    Enhanced radiosensitivity is an uncommon phenomenon attributable to deficient DNA repair after radiotherapy which can be assessed with the γ-H2AX assay. Reports of radiosensitivity after stereotactic radiosurgery (SRS) are uncommon. We describe a case where the clinical, radiological and laboratory findings suggest enhanced radiosensitivity after SRS for an acoustic neuroma.

  10. Haemorrhagic acoustic neuroma with features of a vascular malformation. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Benhaiem-Sigaux, N. [Dept. of Pathology, Hopital Henri Mondor, Creteil (France); Ricolfi, F. [Dept. of Neuroradiology, Henri Mondor Hospital, Creteil (France); Torres-Diaz, A.; Keravel, Y. [Dept. of Neurosurgery, Henri Mondo Hospital, Creteil (France); Poirier, J. [Dept. of Histology, Pitie-Salpetriere Hospital, Paris (France)

    1999-10-01

    A 55-year-old man with hearing loss presented with vertigo and vomiting. CT tomography and MRI demonstrated a cerebellopontine angle mass with foci of haemorrhage. An angiomatous tumour, with large abnormal veins adhering to the capsule, was completely removed. Histologically, the tumour was an acoustic neuroma with abnormal vascularisation and limited intratumoral haemorrhage. (orig.)

  11. Haemorrhagic acoustic neuroma with features of a vascular malformation. A case report

    International Nuclear Information System (INIS)

    Benhaiem-Sigaux, N.; Ricolfi, F.; Torres-Diaz, A.; Keravel, Y.; Poirier, J.

    1999-01-01

    A 55-year-old man with hearing loss presented with vertigo and vomiting. CT tomography and MRI demonstrated a cerebellopontine angle mass with foci of haemorrhage. An angiomatous tumour, with large abnormal veins adhering to the capsule, was completely removed. Histologically, the tumour was an acoustic neuroma with abnormal vascularisation and limited intratumoral haemorrhage. (orig.)

  12. Radiosurgery supported in the lineal accelerator for the acoustic neuroma treatment

    International Nuclear Information System (INIS)

    Santos Ortega, M.; Gutierrez Diaz, J.; Rodriguez Villaba, S.; Garcia Berrocal, I.; Samblas Garcia, J.; Bustos Perez de Salcedo, J.C.; Ortiz de Urbina, D.; Donckaster Clavero, G.; Delgado Rodriguez, J.M.; Sansivirini Valle, F.

    1996-01-01

    Radiosurgery becomes in a great interest technique in acoustic neuroma treatments. We present preliminary results over 74 neurinomas patients in our Unit. From August 1991 to August 1994, 74 consecutive patients with acoustic neuromas, median age 50 yrs. has been treated in our Unit. A SRS 200 radiosurgery system was employed using a 6 MV photon beam Linear Accelerator as radiation source. In every case treatment dose was lesser than 18 gy (14-16 Gy). Before treatment all patients were evaluated with MRI and neurological examination, acoustic test included. This screening was repeated each six months during the follow up. Tumoral control was defined both, as no changes or diminishing in tumoral size, observed in sequential MRI studies with gadolinium and comparable techniques. The median fallow up is 18 months. Tumor control is 88,5%. In 30 patients control means dismissing in tumoral size. In 10 patients tumoral progression was evident, in a half of their a neurofibromatosis type II was previously diagnosed. The neurological function during the follow up shown improve or estabilitation in symptoms, for 85% VII pair patients, 83% in VII pair patients, 86% in V pair patients and 83% in cerebellar disfunction patients. Although preliminaries, this dates showing the efficacy of radiosurgery in tumoral control of patients with neurinomas with doses laser than 18 Gy. This dose are safe with toxicities around 15%, mainly in transitory presentations. (Auhtor) 67 refs

  13. Acoustic neuroma: predominance of Antoni type B cells in tumors of patients with vestibular paresis.

    NARCIS (Netherlands)

    Stipkovits, E.M.; Graamans, K.; Jansen, G.H.; Velthof, M.A.

    2001-01-01

    OBJECTIVE: This study aimed to investigate whether in patients with acoustic neuroma (AN), the presence or absence of vestibular symptoms is related to the histologic characteristics of the tumor. STUDY DESIGN: The study design was a retrospective clinical study. SETTING: The study was conducted at

  14. A case-case study of mobile phone use and acoustic neuroma risk in Japan.

    Science.gov (United States)

    Sato, Yasuto; Akiba, Suminori; Kubo, Osami; Yamaguchi, Naohito

    2011-02-01

    Results of case-control studies of mobile phone use and acoustic neuroma have been inconsistent. We conducted a case-case study of mobile phone use and acoustic neuroma using a self-administered postal questionnaire. A total of 1589 cases identified in 22 hospitals throughout Japan were invited to participate, and 787 cases (51%) actually participated. Associations between laterality of mobile phone use prior to the reference dates (1 and 5 years before diagnosis) and tumor location were analyzed. The overall risk ratio was 1.08 (95% confidence interval (CI), 0.93-1.28) for regular mobile phone use until 1 year before diagnosis and 1.14 (95% CI, 0.96-1.40) for regular mobile phone use until 5 years before diagnosis. A significantly increased risk was identified for mobile phone use for >20 min/day on average, with risk ratios of 2.74 at 1 year before diagnosis, and 3.08 at 5 years before diagnosis. Cases with ipsilateral combination of tumor location and more frequently used ear were found to have tumors with smaller diameters, suggesting an effect of detection bias. Furthermore, analysis of the distribution of left and right tumors suggested an effect of tumor-side-related recall bias for recall of mobile phone use at 5 years before diagnosis. The increased risk identified for mobile phone users with average call duration >20 min/day should be interpreted with caution, taking into account the possibilities of detection and recall biases. However, we could not conclude that the increased risk was entirely explicable by these biases, leaving open the possibility that mobile phone use increased the risk of acoustic neuroma. Copyright © 2010 Wiley-Liss, Inc.

  15. Treatment of acoustic neuroma: stereotactic radiosurgery vs. microsurgery

    International Nuclear Information System (INIS)

    Karpinos, Marianna; Teh, Bin S.; Zeck, Otto; Carpenter, L. Steven; Phan, Chris; Mai, W.-Y.; Lu, Hsin H.; Chiu, J. Kam; Butler, E. Brian; Gormley, William B.; Woo, Shiao Y.

    2002-01-01

    Purpose: Two major treatment options are available for patients with acoustic neuroma, microsurgery and radiosurgery. Our objective was to compare these two treatment modalities with respect to tumor growth control, hearing preservation, development of cranial neuropathies, complications, functional outcome, and patient satisfaction. Methods and Materials: To compare radiosurgery with microsurgery, we analyzed 96 patients with unilateral acoustic neuromas treated with Leksell Gamma Knife or microsurgery at Memorial Hermann Hospital, Houston, Texas, between 1993 and 2000. Radiosurgery technique involved multiple isocenter (1-30 single fraction fixed-frame magnetic resonance imaging) image-based treatment with a mean dose prescription of 14.5 Gy. Microsurgery included translabyrinthine, suboccipital, and middle fossa approaches with intraoperative neurophysiologic monitoring. Preoperative patient characteristics were similar except for tumor size and age. Patients undergoing microsurgery were younger with larger tumors compared to the radiosurgical group. The tumors were divided into small 4.0 cm. Median follow-up of the radiosurgical group was longer than the microsurgical group, 48 months (3-84 months) vs. 24 months (3-72 months). Results: There was no statistical significance in tumor growth control between the two groups, 100% in the microsurgery group vs. 91% in the radiosurgery group (p>0.05). Radiosurgery was more effective than microsurgery in measurable hearing preservation, 57.5% vs. 14.4% (p=0.01). There was no difference in serviceable hearing preservation between the two groups. Microsurgery was associated with a greater rate of facial and trigeminal neuropathy in the immediate postoperative period and at long-term follow-up. The rate of development of facial neuropathy was significantly higher in the microsurgical group than in the radiosurgical group (35% vs. 0%, p<0.01 in the immediate postsurgical period and 35.3% vs. 6.1%, p=0.008, at long

  16. Treatment of acoustic neuroma: stereotactic radiosurgery vs. microsurgery

    Energy Technology Data Exchange (ETDEWEB)

    Karpinos, Marianna; Teh, Bin S; Zeck, Otto; Carpenter, L Steven; Phan, Chris; Mai, W -Y; Lu, Hsin H; Chiu, J Kam; Butler, E Brian; Gormley, William B; Woo, Shiao Y

    2002-12-01

    Purpose: Two major treatment options are available for patients with acoustic neuroma, microsurgery and radiosurgery. Our objective was to compare these two treatment modalities with respect to tumor growth control, hearing preservation, development of cranial neuropathies, complications, functional outcome, and patient satisfaction. Methods and Materials: To compare radiosurgery with microsurgery, we analyzed 96 patients with unilateral acoustic neuromas treated with Leksell Gamma Knife or microsurgery at Memorial Hermann Hospital, Houston, Texas, between 1993 and 2000. Radiosurgery technique involved multiple isocenter (1-30 single fraction fixed-frame magnetic resonance imaging) image-based treatment with a mean dose prescription of 14.5 Gy. Microsurgery included translabyrinthine, suboccipital, and middle fossa approaches with intraoperative neurophysiologic monitoring. Preoperative patient characteristics were similar except for tumor size and age. Patients undergoing microsurgery were younger with larger tumors compared to the radiosurgical group. The tumors were divided into small <2.0 cm, medium 2.0-3.9 cm, or large >4.0 cm. Median follow-up of the radiosurgical group was longer than the microsurgical group, 48 months (3-84 months) vs. 24 months (3-72 months). Results: There was no statistical significance in tumor growth control between the two groups, 100% in the microsurgery group vs. 91% in the radiosurgery group (p>0.05). Radiosurgery was more effective than microsurgery in measurable hearing preservation, 57.5% vs. 14.4% (p=0.01). There was no difference in serviceable hearing preservation between the two groups. Microsurgery was associated with a greater rate of facial and trigeminal neuropathy in the immediate postoperative period and at long-term follow-up. The rate of development of facial neuropathy was significantly higher in the microsurgical group than in the radiosurgical group (35% vs. 0%, p<0.01 in the immediate postsurgical period and 35

  17. Acoustic neuromas: single dose vs fractionated therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fuss, M; Debus, J; Lohr, F; Engenhart-Cabillic, R; Wannenmacher, M

    1997-07-01

    Purpose: Radiosurgical treatment (RS) of acoustic neuromas is a well established treatment. However, few data are available concerning conformal fractionated radiotherapy (FT) of this tumor entity. We evaluated treatment outcome and toxicity for both treatment modalities in 41 patients treated at our institution between 1984 and 1997. Material and Methods: All treatments were performed using a specially adapted linear accelerator and circular collimators for convergent beam RS or multi-leaf collimators (leaf thickness 1 or 3mm) for multi-field RS or fractionated treatment. 22 patients (7 male, 15 female, median age 60 years, range 20-83 years) were treated radiosurgically with single doses between 7 and 28 Gray (median 15 Gy) prescribed to the 80% isodose line. Tumor volumes ranged from 0.7 to 10.5 ccm with a median volume of 3.4 ccm. The median number of isocenters was 2 (1-4 isocenters). One patient was treated by a multi-field technique (14 isocentric irregularly shaped noncoplanar fields). 19 patients (5 male, 14 female, median age 55 years, range 20-81 years) were treated with stereotactic conformal radiotherapy. Median dose was 60 Gray with a median daily fraction size of 2 Gy and a median of 3 (1-4) irregularly shaped isocentric fields. Tumor volumes ranged from 0.7 to 32.4 ccm (median 15 ccm). Median follow-up was 30 months (7-149 months) for radiosurgical and 30 months (2-88 months) for fractionated treatment. Seven patients who underwent fractionated treatment had previously undergone neurosurgical resection on the contralateral side. One had undergone radiosurgery on the opposite side before. Results: All tumors were locally controlled. A volume reduction of more than 20% was seen in 16% after RS and 18% following FT. Typical posttherapeutic central reduction of contrast media enhancement was found in 73% following RS after a median of 8 (3-12) months and in 63% following FT after a median of 6 (1-12) months. Temporary brainstem edema was diagnosed in 4

  18. SU-E-T-14: A Comparative Study Between Forward and Inverse Planning in Gamma Knife Radiosurgery for Acoustic Neuroma Tumours

    Energy Technology Data Exchange (ETDEWEB)

    Gopishankar, N; Agarwal, Priyanka; Bisht, Raj Kishor; Kale, S S; Rath, G K; Chander, S; Sharma, B S [All India Institute of Medical Sciences, New Delhi (India)

    2015-06-15

    Purpose: To evaluate forward and inverse planning methods for acoustic neuroma cases treated in Gamma Knife Perfexion. Methods: Five patients with acoustic neuroma tumour abutting brainstem were planned twice in LGP TPS (Version 10.1) using TMR10 algorithm. First plan was entirely based on forward planning (FP) in which each shot was chosen manually. Second plan was generated using inverse planning (IP) for which planning parameters like coverage, selectivity, gradient index (GI) and beam-on time threshold were set. Number of shots in IP was automatically selected by objective function using iterative process. In both planning methods MRI MPRAGE sequence images were used for tumour localization and planning. A planning dose of 12Gy at 50% isodose level was chosen. Results and Discussion: Number of shots used in FP was greater than IP and beam-on time in FP was in average 1.4 times more than IP. One advantage of FP was that the brainstem volume subjected to 6Gy dose (25% isodose) was less in FP than IP. Our results showed use of more number of shots as in FP results in GI less than or equal to 2.55 which is close to its lower limit. Dose homogeneity index (DHI) analysis of FP and IP showed average values of 0.59 and 0.67 respectively. General trend in GK for planning in acoustic neuroma cases is to use small collimator shots to avoid dose to adjacent critical structures. More number of shots and prolonged treatment time causes inconvenience to the patients. Similarly overuse of automatic shot shaping as in IP results in increased scatter dose. A compromise is required in shot selection for these cases. Conclusion: IP method could be used in acoustic neuroma cases to decrease treatment time provided the source sector openings near brainstem are shielded or adjusted appropriately to reduce brainstem dose.

  19. [Descending hypoglossal branch-facial nerve anastomosis in treating unilateral facial palsy after acoustic neuroma resection].

    Science.gov (United States)

    Liang, Jiantao; Li, Mingchu; Chen, Ge; Guo, Hongchuan; Zhang, Qiuhang; Bao, Yuhai

    2015-12-15

    To evaluate the efficiency of the descending hypoglossal branch-facial nerve anastomosis for the severe facial palsy after acoustic neuroma resection. The clinical data of 14 patients (6 males, 8 females, average age 45. 6 years old) underwent descending hypoglossal branch-facial nerve anastomosis for treatment of unilateral facial palsy was analyzed retrospectively. All patients previously had undergone resection of a large acoustic neuroma. House-Brackmann (H-B) grading system was used to evaluate the pre-, post-operative and follow up facial nerve function status. 12 cases (85.7%) had long follow up, with an average follow-up period of 24. 6 months. 6 patients had good outcome (H-B 2 - 3 grade); 5 patients had fair outcome (H-B 3 - 4 grade) and 1 patient had poor outcome (H-B 5 grade) Only 1 patient suffered hemitongue myoparalysis owing to the operation. Descending hypoglossal branch-facial nerve anastomosis is effective for facial reanimation, and it has little impact on the function of chewing, swallowing and pronunciation of the patients compared with the traditional hypoglossal-facial nerve anastomosis.

  20. Fractionated stereotactic radiation therapy and single high-dose radiosurgery for acoustic neuroma: early results of a prospective clinical study

    International Nuclear Information System (INIS)

    Meijer, O.W.M.; Wolbers, J.G.; Baayen, J.C.; Slotman, B.J.

    2000-01-01

    Purpose: To prospectively assess the local control and toxicity rate in acoustic neuroma patients treated with linear accelerator-based radiosurgery and fractionated stereotactic radiation therapy. Methods and Materials: We evaluated 37 consecutive patients treated with stereotactic radiation therapy for acoustic neuroma. All patients had progressive tumors, progressive symptoms, or both. Mean tumor diameter was 2.3 cm (range 0.8-3.3) on magnetic resonance (MR) scan. Dentate patients were given a dose of 5 x 4 Gy or 5 x 5 Gy and edentate patients were given a dose of 1 x 10 Gy or 1 x 12.50 Gy prescribed to the 80% isodose. All patients were treated with a single isocenter. Results: With a mean follow-up period of 25 months (range 12-61), the actuarial local control rate at 5 years was 91% (only 1 patient failed). The actuarial rate of hearing preservation at 5 years was 66% in previously-hearing patients. The actuarial rate of freedom from trigeminal nerve toxicity was 97% at 5 years. No patient developed facial nerve toxicity or other complications. Conclusion: In this unselected series, fractionated stereotactic radiation therapy and linear accelerator-based radiosurgery give excellent local control in acoustic neuroma. It combines a high rate of preservation of hearing with a very low rate of other toxicity, although follow-up is relatively short

  1. Vestibular Schwannoma or acoustic neuroma

    Directory of Open Access Journals (Sweden)

    Hekmatara M

    1997-04-01

    Full Text Available Vestibular schwannoma is the most common tumor of the posterior fossa of the skull. Patients referred with the primary otologic symptoms such as hearing loss, tinnitus, vertigo, imbalance, and the cranial nerve palsy. Thirty-three patients were operated and treated by a team of otolaryngologist and neurosurgeon, anudiometrist, and internist. Patients'chiefcomplaint was due to 94% hearing loss and 27% tinnitus. They scarcely complain of vertigo. If a patient refers with the palsy or paralysis of facial nerve preoperation, we must think of the facial nerve schwannoma or hemangioma or congential cholestoma or malignant metastases rather than acoustic neuroma. The best way for preoperative diagnosis is audiometry, ABR (Auditory Brain Response, and SDS (speech discrimination score with 90% success, but computer Tomography (CT scan and MRI (Magnetic Resonance Image are the valuable anatomic diagnostic radiographic devices. The best method of operation is translabirynthine approach (TLA, since it has the advantages such as an easy access to nerve paths and being the nearest path to CPA (Cerebellopontine Angle. Physicians ought to talk to patients about the importance of the microscopic surgery, surgical methods, and their probable diverse effects such as hearing loss, facial nerve palsy, and intracranial problems.

  2. MR of acoustic neuromas; Relationship to cranial nerves

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Masayuki; Takashima, Tsutomu; Kadoya, Masumi; Takahashi, Shiroh; Miyayama, Shiroh; Taira, Sakae; Kashihara, Kengo; Yamashima, Tetsumori; Itoh, Haruhide [Kanazawa Univ. (Japan). School of Medicine

    1989-08-01

    In this report, the relationship of acoustic neuromas to the adjacent cranial nerves is discussed. On T{sub 1}-weighted images, the trigeminal nerve was detected in all 13 cases. Mild to marked compression of these nerves by the tumors was observed in eight cases. The extent of compression did not always correspond to the clinical symptoms. In four cases with a maximum tumor diameter of 2 cm or less, the 7th and 8th cranial nerves were identified. There was no facial palsy in these patients. Two patients with a tumor diameter of more than 2 cm also had no facial palsy. All patients, including those with small tumors, complained of hearing loss and/or tinnitus. While MR imaging has some limitations, it is an effective imaging modality for showing the relationship between tumors and nerves. (author).

  3. Prognostic factors for hearing preservation following observation-only versus stereotactic irradiation (STI) in patients with acoustic neuroma

    International Nuclear Information System (INIS)

    Sakamoto, Tooru

    1998-01-01

    Prognostic factors for hearing preservation following observation-only versus STI were compared in patients with acoustic neuroma. There were 48 patients with acoustic neuroma treated by fractionated STI. Between 1991 and 1997, patients were given 36 Gy in 20 fractions over 5 weeks (36 Gy/20 Fr/5 wks) to 44 Gy/22 Fr/6 wks followed by a 4 Gy boost. A linear accelerator was used for irradiation. Twenty-three patients with acoustic neuroma who were followed without any treatment (observation-only group) were selected as matched controls. The largest hearing loss was observed at the frequency of 2 kHz in the observation-only group and at 1-2 kHz in the STI group. Hearing loss at lkHz was more frequent in the STI group (p<0.01). There were no significant prognostic factors which predicted hearing preservation in the observation-only group. Stereotactic irradiation has been suggested to damage to cochlear nerve function in patients whose cochlear nerve had been impaired already. Tumor control rate of STI appeared to be as good as single fraction radiosurgery rates in the literature and better than in the observation-only group. Hearing preservation rate in the STI group was as good as in the observation-only group and appeared to be better than single fraction radiosurgery. In conclusion, because there were no factors predictive of hearing preservation in the observation-only group, it is difficult to select patients for observation only. Fractionated STI is potentially the treatment of choice, resulting in the same hearing preservation rate as achieved with observation only, although longer follow-up periods are needed. (author)

  4. Environmental risk factors for sporadic acoustic neuroma (Interphone Study Group, Germany)

    DEFF Research Database (Denmark)

    Schlehofer, B; Schlaefer, K; Blettner, M

    2007-01-01

    The only known risk factor for sporadic acoustic neuroma is high-dose ionising radiation. Environmental exposures, such as radiofrequency electromagnetic fields and noise are under discussion, as well as an association with allergic diseases. We performed a population-based case-control study.......31; 95% CI 1.15-4.66), and for hay fever (OR=2.20; 95% CI 1.09-4.45), but not for ionising radiation (OR=0.91; 95 % CI 0.51-1.61) or regular mobile phone use (OR=0.67; 95% CI 0.38-1.19). The study confirms results of recently published studies, although the pathogenetic mechanisms are still unknown....

  5. Clinical predictors of facial nerve outcome after translabyrinthine resection of acoustic neuromas.

    Science.gov (United States)

    Shamji, Mohammed F; Schramm, David R; Benoit, Brien G

    2007-01-01

    The translabyrinthine approach to acoustic neuroma resection offers excellent exposure for facial nerve dissection with 95% preservation of anatomic continuity. Acceptable outcome in facial asymptomatic patients is reported at 64-90%, but transient postoperative deterioration often occurs. The objective of this study was to identify preoperative clinical presentation and intraoperative surgical findings that predispose patients to facial nerve dysfunction after acoustic neuroma surgery. The charts of 128 consecutive translabyrinthine patients were examined retrospectively to identify new clinical and intraoperative predictors of facial nerve outcome. Postoperative evaluation of patients to normal function or mild asymmetry upon close inspection (House-Brackmann grades of I or II) was defined as an acceptable outcome, with obvious asymmetry to no movement (grades III to VI) defined as unacceptable. Intraoperative nerve stimulation was performed in all cases, and clinical grading was performed by a single neurosurgeon in all cases. Among patients with no preoperative facial nerve deficit, 87% had an acceptable result. Small size (P mA (P< 0.01) were reaffirmed as predictive of functional nerve preservation. Additionally, preoperative tinnitus (P = 0.03), short duration of hearing loss (P< 0. 01), and lack of subjective tumour adherence to the facial nerve (P = 0.02) were independently correlated with positive outcome. Our experience with the translabyrinthine approach reveals the previously unestablished associations of facial nerve outcome to include presence of tinnitus and duration of hypoacusis. Independent predictors of tumour size and nerve stimulation thresholds were reaffirmed, and the subjective description of tumour adherence to the facial nerve making dissection more difficult appears to be important.

  6. Risk of a second cancer from scattered radiation in acoustic neuroma treatment

    Science.gov (United States)

    Yoon, Myonggeun; Lee, Hyunho; Sung, Jiwon; Shin, Dongoh; Park, Sungho; Chung, Weon Kuu; Jahng, Geon-Ho; Kim, Dong Wook

    2014-06-01

    The present study aimed to compare the risk of a secondary cancer from scattered and leakage doses in patients receiving intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). Four acoustic neuroma patients were treated with IMRT, VMAT, or SRS. Their excess relative risk (ERR), excess absolute risk (EAR), and lifetime attributable risk (LAR) of a secondary cancer were estimated using the corresponding secondary doses measured at various organs by using radio-photoluminescence glass dosimeters (RPLGD) placed inside a humanoid phantom. When a prescription dose was delivered in the planning target volume of the 4 patients, the average organ equivalent doses (OED) at the thyroid, lung, liver, bowel, bladder, prostate (or ovary), and rectum were 14.6, 1.7, 0.9, 0.8, 0.6, 0.6, and 0.6 cGy, respectively, for IMRT whereas they were 19.1, 1.8, 2.0, 0.6, 0.4, 0.4, and 0.4 cGy, respectively, for VMAT, and 22.8, 4.6, 1.4, 0.7, 0.5, 0.5, and 0.5 cGy, respectively, for SRS. The OED decreased as the distance from the primary beam increased. The thyroid received the highest OED compared to other organs. A lifetime attributable risk evaluation estimated that more than 0.03% of acoustic neuroma (AN) patients would get radiation-induced cancer within 20 years of receiving radiation therapy. The organ with the highest radiation-induced cancer risk after radiation treatment for AN was the thyroid. We found that the LAR could be increased by the transmitted dose from the primary beam. No modality-specific difference in radiation-induced cancer risk was observed in our study.

  7. Risk of a second cancer from scattered radiation in acoustic neuroma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Myonggeun; Lee, Hyunho; Sung, Jiwon [Korea University, Seoul (Korea, Republic of); Shin, Dongoh [Kyung Hee University Medical Center, Seoul (Korea, Republic of); Park, Sungho [Ulsan University Hospital, Ulsan (Korea, Republic of); Chung, Weonkuu; Jahng, Geonho; Kim, Dongwook [Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of)

    2014-06-15

    The present study aimed to compare the risk of a secondary cancer from scattered and leakage doses in patients receiving intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). Four acoustic neuroma patients were treated with IMRT, VMAT, or SRS. Their excess relative risk (ERR), excess absolute risk (EAR), and lifetime attributable risk (LAR) of a secondary cancer were estimated using the corresponding secondary doses measured at various organs by using radio-photoluminescence glass dosimeters (RPLGD) placed inside a humanoid phantom. When a prescription dose was delivered in the planning target volume of the 4 patients, the average organ equivalent doses (OED) at the thyroid, lung, liver, bowel, bladder, prostate (or ovary), and rectum were 14.6, 1.7, 0.9, 0.8, 0.6, 0.6, and 0.6 cGy, respectively, for IMRT whereas they were 19.1, 1.8, 2.0, 0.6, 0.4, 0.4, and 0.4 cGy, respectively, for VMAT, and 22.8, 4.6, 1.4, 0.7, 0.5, 0.5, and 0.5 cGy, respectively, for SRS. The OED decreased as the distance from the primary beam increased. The thyroid received the highest OED compared to other organs. A lifetime attributable risk evaluation estimated that more than 0.03% of acoustic neuroma (AN) patients would get radiation-induced cancer within 20 years of receiving radiation therapy. The organ with the highest radiation-induced cancer risk after radiation treatment for AN was the thyroid. We found that the LAR could be increased by the transmitted dose from the primary beam. No modality-specific difference in radiation-induced cancer risk was observed in our study.

  8. Validation of the facial dysfunction domain of the Penn Acoustic Neuroma Quality-of-Life (PANQOL) Scale.

    Science.gov (United States)

    Lodder, Wouter L; Adan, Guleed H; Chean, Chung S; Lesser, Tristram H; Leong, Samuel C

    2017-06-01

    The objective of this study is to evaluate the strength of content validity within the facial dysfunction domain of the Penn Acoustic Neuroma Quality-of-Life (PANQOL) Scale and to compare how it correlates with a facial dysfunction-specific QOL instrument (Facial Clinimetric Evaluation, FaCE). The study design is online questionnaire survey. Members of the British Acoustic Neuroma Association received both PANQOL questionnaires and the FaCE scale. 158 respondents with self-identified facial paralysis or dysfunction had completed PANQOL and FaCE data sets for analysis. The mean composite PANQOL score was 53.5 (range 19.2-93.5), whilst the mean total FaCE score was 50.9 (range 10-95). The total scores of the PANQOL and FaCE correlated moderate (r = 0.48). Strong correlation (r = 0.63) was observed between the PANQOL's facial dysfunction domain and the FaCE total score. Of all the FaCE domains, social function was strongly correlated with the PANQOL facial dysfunction domain (r = 0.66), whilst there was very weak-to-moderate correlation (range 0.01-0.43) to the other FaCE domains. The current study has demonstrated a strong correlation between the facial dysfunction domains of PANQOL with a facial paralysis-specific QOL instrument.

  9. Acoustic neuromas: single dose vs fractionated therapy

    International Nuclear Information System (INIS)

    Fuss, M.; Debus, J.; Lohr, F.; Engenhart-Cabillic, R.; Wannenmacher, M.

    1997-01-01

    Purpose: Radiosurgical treatment (RS) of acoustic neuromas is a well established treatment. However, few data are available concerning conformal fractionated radiotherapy (FT) of this tumor entity. We evaluated treatment outcome and toxicity for both treatment modalities in 41 patients treated at our institution between 1984 and 1997. Material and Methods: All treatments were performed using a specially adapted linear accelerator and circular collimators for convergent beam RS or multi-leaf collimators (leaf thickness 1 or 3mm) for multi-field RS or fractionated treatment. 22 patients (7 male, 15 female, median age 60 years, range 20-83 years) were treated radiosurgically with single doses between 7 and 28 Gray (median 15 Gy) prescribed to the 80% isodose line. Tumor volumes ranged from 0.7 to 10.5 ccm with a median volume of 3.4 ccm. The median number of isocenters was 2 (1-4 isocenters). One patient was treated by a multi-field technique (14 isocentric irregularly shaped noncoplanar fields). 19 patients (5 male, 14 female, median age 55 years, range 20-81 years) were treated with stereotactic conformal radiotherapy. Median dose was 60 Gray with a median daily fraction size of 2 Gy and a median of 3 (1-4) irregularly shaped isocentric fields. Tumor volumes ranged from 0.7 to 32.4 ccm (median 15 ccm). Median follow-up was 30 months (7-149 months) for radiosurgical and 30 months (2-88 months) for fractionated treatment. Seven patients who underwent fractionated treatment had previously undergone neurosurgical resection on the contralateral side. One had undergone radiosurgery on the opposite side before. Results: All tumors were locally controlled. A volume reduction of more than 20% was seen in 16% after RS and 18% following FT. Typical posttherapeutic central reduction of contrast media enhancement was found in 73% following RS after a median of 8 (3-12) months and in 63% following FT after a median of 6 (1-12) months. Temporary brainstem edema was diagnosed in 4

  10. Intermedius nerve involvement and testing in acoustic neuromas.

    Science.gov (United States)

    Thomsen, J; Zilstorff, K

    1975-01-01

    The clinical findings in 125 patients with surgically confirmed acoustic neuromas are presented, with special regard to the involvement of the intermedius nerve in the diagnosis. In assessing the function of the intermedius nerve the examination of the nasolacrimal reflex and the sensation of taste on the anterior two-thirds of the tongue are used. The methods of investigation are described in detail. The material consisted of 20 medium-sized and 105 large tumours; no intracanalicular tumor was found. Hearing loss was the initial symptom in 85% of the patients, 10% had tinitus and 4% vertigo as the first symptom. Apart from the VIII cranial nerve symptoms, a defective nasolacrimal reflex was the most significant evidence of cerebellopontine angle pathology. The test was positive in 65% of the medium-sized tumours, in the entire material, 85%. The figures are higher than the incidence of trigeminal nerve symptoms. This in contrast to the reports of most authors. The tests described are simple and quick to perform, and it is emphasized that they should be applied to all patients with unilateral hearing loss of unknown origin.

  11. Acoustic neuroma risk in relation to mobile telephone use: Results of the INTERPHONE international case-control study

    DEFF Research Database (Denmark)

    Berg-Beckhoff, Gabi

    2011-01-01

    Background: The rapid increase in mobile telephone use has generated concern about possible health risks of radiofrequency electromagnetic fields from these devices. Methods: A case-control study of 1105 patients with newly diagnosed acoustic neuroma (vestibular schwannoma) and 2145 controls...... was conducted in 13 countries using a common protocol. Past mobile phone use was assessed by personal interview. In the primary analysis, exposure time was censored at one year before the reference date (date of diagnosis for cases and date of diagnosis of the matched case for controls); analyses censoring...

  12. Pooled analysis of case-control studies on acoustic neuroma diagnosed 1997-2003 and 2007-2009 and use of mobile and cordless phones.

    Science.gov (United States)

    Hardell, Lennart; Carlberg, Michael; Söderqvist, Fredrik; Mild, Kjell Hansson

    2013-10-01

    We previously conducted a case-control study of acoustic neuroma. Subjects of both genders aged 20-80 years, diagnosed during 1997-2003 in parts of Sweden, were included, and the results were published. We have since made a further study for the time period 2007-2009 including both men and women aged 18-75 years selected from throughout the country. These new results for acoustic neuroma have not been published to date. Similar methods were used for both study periods. In each, one population-based control, matched on gender and age (within five years), was identified from the Swedish Population Registry. Exposures were assessed by a self-administered questionnaire supplemented by a phone interview. Since the number of acoustic neuroma cases in the new study was low we now present pooled results from both study periods based on 316 participating cases and 3,530 controls. Unconditional logistic regression analysis was performed, adjusting for age, gender, year of diagnosis and socio-economic index (SEI). Use of mobile phones of the analogue type gave odds ratio (OR) = 2.9, 95% confidence interval (CI) = 2.0-4.3, increasing with >20 years latency (time since first exposure) to OR = 7.7, 95% CI = 2.8-21. Digital 2G mobile phone use gave OR = 1.5, 95% CI = 1.1-2.1, increasing with latency >15 years to an OR = 1.8, 95% CI = 0.8-4.2. The results for cordless phone use were OR = 1.5, 95% CI = 1.1-2.1, and, for latency of >20 years, OR = 6.5, 95% CI = 1.7-26. Digital type wireless phones (2G and 3G mobile phones and cordless phones) gave OR = 1.5, 95% CI = 1.1-2.0 increasing to OR = 8.1, 95% CI = 2.0-32 with latency >20 years. For total wireless phone use, the highest risk was calculated for the longest latency time >20 years: OR = 4.4, 95% CI = 2.2-9.0. Several of the calculations in the long latency category were based on low numbers of exposed cases. Ipsilateral use resulted in a higher risk than contralateral for both mobile and cordless phones. OR increased per 100 h

  13. Intratemporal facial nerve neuromas and their mimics: CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Chang, Kee Hyun; Lee, Kyung Hwan; Cha, Sang Hoon; Kim, Chong Sun [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Sang Joon [Chungang Gil General Hospital, Seoul (Korea, Republic of)

    1992-05-15

    CT and MR findings of nine cases with intra temporal facial nerve neuromas were described and compared with CT findings of 3 cases with facial nerve palsy and facial nerve canal erosion which may mimic facial nerve neuroma. The tympanic segment of the facial nerve was involved in 8 cases, mastoid segment in 7 cases and labyrinthine segment in 5 cases. The lesions were easily diagnosed with high resolution CT with bone algorithms by showing the expansion of bony structures along the course of the facial nerves. In 4 cases with large vertical segment tumors, extensive destruction of mastoid air cells and external auditory canals posed difficulty in making a diagnosis. Two out of 5 cases with labyrinthine segment involvement were presented as middle cranial fossa masses. MRI with enhancement was performed in 4 cases and was useful in characterizing the lesion as a tumor with its superior sensitivity to enhancement. Three cases of facial neuroma-mimicking lesion including post-inflammatory peri neural thickening, peri neural extension from parotid adenoid cystic carcinoma, and congenita; cholesteatoma showed irregular erosion or mild expansion of the facial nerve canal which may be helpful for differential diagnosis from neuromas.

  14. Hypofractionated stereotactic radiotherapy of acoustic neuroma. Volume changes and hearing results after 89-month median follow-up

    International Nuclear Information System (INIS)

    Kranzinger, Manfred; Fastner, Gerd; Zehentmayr, Franz; Sedlmayer, Felix; Oberascher, Gerhard; Merz, Florian; Rahim, Hassan; Nairz, Olaf

    2014-01-01

    The goal of this work was to evaluate toxicity and local control following hypofractionated stereotactic radiation treatment with special focus on changes in tumor volume and hearing capacity. In all, 29 patients with unilateral acoustic neuroma were treated between 2001 and 2007 within a prospective radiation protocol (7 x 4 Gy ICRU dose). Median tumor volume was 0.9 ml. Follow-up started at 6 months and was repeated annually with MRI volumetry and audiometry. Hearing preservation was defined as preservation of Class A/B hearing according to the guidelines of the American Academy of Otolaryngology (1995). No patient had any intervention after a median imaging follow-up of 89.5 months, one patient showed radiological progression. Transient increase of tumor volume developed in 17/29 patients, whereas 22/29 patients (75.9 %) presented with a volume reduction at last follow-up. A total of 21 patients were eligible for hearing evaluation. Mean pure tone average (PTA) deteriorated from 39.3 to 65.9 dB and mean speech discrimination score (SDS) dropped from 74.3 to 38.1 %. The 5-year actuarial Class A/B hearing preservation rate was 50.0 ± 14.4 %. Radiation increases only minimally, if at all, the hearing deterioration which emerges by observation alone. Presbyacusis is not responsible for this deterioration. Transient tumor enlargement is common. Today radiation of small- and medium-sized acoustic neuroma can be performed with different highly conformal techniques as fractionated treatment or single low-dose radiosurgery with equal results regarding tumor control, hearing preservation, and side effects. Hypofractionation is more comfortable for the patient than conventional regimens and represents a serious alternative to frameless radiosurgery. (orig.) [de

  15. Pooled analysis of case-control studies on acoustic neuroma diagnosed 1997–2003 and 2007–2009 and use of mobile and cordless phones

    Science.gov (United States)

    HARDELL, LENNART; CARLBERG, MICHAEL; SÖDERQVIST, FREDRIK; MILD, KJELL HANSSON

    We previously conducted a case-control study of acoustic neuroma. Subjects of both genders aged 20–80 years, diagnosed during 1997–2003 in parts of Sweden, were included, and the results were published. We have since made a further study for the time period 2007–2009 including both men and women aged 18–75 years selected from throughout the country. These new results for acoustic neuroma have not been published to date. Similar methods were used for both study periods. In each, one population-based control, matched on gender and age (within five years), was identified from the Swedish Population Registry. Exposures were assessed by a self-administered questionnaire supplemented by a phone interview. Since the number of acoustic neuroma cases in the new study was low we now present pooled results from both study periods based on 316 participating cases and 3,530 controls. Unconditional logistic regression analysis was performed, adjusting for age, gender, year of diagnosis and socio-economic index (SEI). Use of mobile phones of the analogue type gave odds ratio (OR) = 2.9, 95% confidence interval (CI) = 2.0–4.3, increasing with >20 years latency (time since first exposure) to OR = 7.7, 95% CI = 2.8–21. Digital 2G mobile phone use gave OR = 1.5, 95% CI = 1.1–2.1, increasing with latency >15 years to an OR = 1.8, 95% CI = 0.8–4.2. The results for cordless phone use were OR = 1.5, 95% CI = 1.1–2.1, and, for latency of >20 years, OR = 6.5, 95% CI = 1.7–26. Digital type wireless phones (2G and 3G mobile phones and cordless phones) gave OR = 1.5, 95% CI = 1.1–2.0 increasing to OR = 8.1, 95% CI = 2.0–32 with latency >20 years. For total wireless phone use, the highest risk was calculated for the longest latency time >20 years: OR = 4.4, 95% CI = 2.2–9.0. Several of the calculations in the long latency category were based on low numbers of exposed cases. Ipsilateral use resulted in a higher risk than contralateral for both mobile and cordless

  16. Management of a patient undergoing sitting position craniotomy for acoustic neuroma with co-existing interstitial lung disease

    Directory of Open Access Journals (Sweden)

    Deepa Suvarna

    2015-01-01

    Full Text Available A 38-year-old woman with acoustic neuroma associated with occupational interstitial lung disease (ILD was successfully managed for sitting position craniotomy using carefully titrated desflurane-based anaesthesia. The anaesthetic challenges included maintenance an adequate depth of anaesthesia, reducing perioperative airway events and ensuring smooth recovery. While dealing with ILD patient in sitting position, careful risk assessment is important because it will help us predict the course of the perioperative events. Balanced general anaesthesia using desflurane fulfilled the requirement of good depth and smooth recovery in this patient. Though there are reports of maintenance of anaesthesia with other inhalational agents, there are scanty reports of using desflurane in these cases.

  17. Associação entre tamanho e potencial proliferativo em neurinomas do acústico Size and proliferative index correlation in acoustic neuromas

    Directory of Open Access Journals (Sweden)

    Oswaldo Inácio de Tella

    2006-03-01

    Full Text Available Schwanomas do acústico são os tumores mais freqüentes localizados no ângulo pontocerebelar. Os mecanismos moleculares que levam a sua geração e crescimento ainda não são bem conhecidos. Várias características clínicas, radiológicas e imuno-histoquímicas já foram estudadas e correlacionadas ao crescimento tumoral. Estudamos e correlacionamos aspectos clínicos e imuno-histoquímicos (MIB-1 de 11 schwanomas do acústico operados no Hospital São Paulo/UNIFESP. O tamanho dos tumores correlacionou-se com o índice proliferativo (Ki-67, não havendo correlação com significância estatística entre a idade dos pacientes, duração dos sintomas e índice proliferativo.Acoustic neuromas are the most common tumors in the cerebellopontine angle. The molecular mechanisms involved in generation and growth of these tumors are not completly elucidated. Many radiological, clinic and imunohistochemystry data were correlated to tumor growth. We studied 11 acoustic neuromas surgically treated at Hospital São Paulo/Unifesp and correlated clinical and radiological data with proliferative index (Ki-67. The size of the tumors were positively correlationated with proliferative index. No other correlation had statistic significativity.

  18. MRI features of peripheral traumatic neuromas

    Energy Technology Data Exchange (ETDEWEB)

    Ahlawat, Shivani [Johns Hopkins University School of Medicine, Musculoskeletal Radiology Section, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Belzberg, Allan J. [The Johns Hopkins Hospital, Department of Neurosurgery, Baltimore, MD (United States); Montgomery, Elizabeth A. [The Johns Hopkins Hospital, Pathology, Oncology and Orthopedic Surgery, Baltimore, MD (United States); Fayad, Laura M. [Department of Orthopedic Surgery, Department of Radiology and Radiological Science, Musculoskeletal Imaging Section Chief, The Johns Hopkins Medical Institutions, Baltimore, MD (United States); The Johns Hopkins Medical Institutions, Department of Orthopedic Surgery, Baltimore, MD (United States)

    2016-04-15

    To describe the MRI appearance of traumatic neuromas on non-contrast and contrast-enhanced MRI sequences. This IRB-approved, HIPAA-compliant study retrospectively reviewed 13 subjects with 20 neuromas. Two observers reviewed pre-operative MRIs for imaging features of neuroma (size, margin, capsule, signal intensity, heterogeneity, enhancement, neurogenic features and denervation) and the nerve segment distal to the traumatic neuroma. Descriptive statistics were reported. Pearson's correlation was used to examine the relationship between size of neuroma and parent nerve. Of 20 neuromas, 13 were neuromas-in-continuity and seven were end-bulb neuromas. Neuromas had a mean size of 1.5 cm (range 0.6-4.8 cm), 100 % (20/20) had indistinct margins and 0 % (0/20) had a capsule. Eighty-eight percent (7/8) showed enhancement. All 100 % (20/20) had tail sign; 35 % (7/20) demonstrated discontinuity from the parent nerve. None showed a target sign. There was moderate positive correlation (r = 0.68, p = 0.001) with larger neuromas arising from larger parent nerves. MRI evaluation of the nerve segment distal to the neuroma showed increased size (mean size 0.5 cm ± 0.4 cm) compared to the parent nerve (mean size 0.3 cm ± 0.2 cm). Since MRI features of neuromas include enhancement, intravenous contrast medium cannot be used to distinguish neuromas from peripheral nerve sheath tumours. The clinical history of trauma with the lack of a target sign are likely the most useful clues. (orig.)

  19. Management of acoustic neuromas with fractionated stereotactic radiotherapy (FSRT): Long-term results in 106 patients treated in a single institution

    International Nuclear Information System (INIS)

    Combs, Stephanie E.; Volk, Sigrid; Schulz-Ertner, Daniela; Huber, Peter E.; Thilmann, Christoph; Debus, Juergen

    2005-01-01

    Purpose: To assess the long-term outcome and toxicity of fractionated stereotactic radiotherapy for acoustic neuromas in 106 patients treated in a single institution. Patients and Methods: Between October 1989 and January 2004, fractionated stereotactic radiotherapy (FSRT) was performed in 106 patients with acoustic neuroma (AN). The median total dose applied was 57.6 Gy in median single fractions of 1.8 Gy in five fractions per week. The median irradiated tumor volume was 3.9 mL (range, 2.7-30.7 mL). The median follow-up time was 48.5 months (range, 3-172 months). Results: Fractionated stereotactic radiotherapy was well tolerated in all patients. Actuarial local tumor control rates at 3- and 5- years after FSRT were 94.3% and 93%, respectively. Actuarial useful hearing preservation was 94% at 5 years. The presence of neurofibromatosis (NF-2) significantly adversely influenced hearing preservation in patients that presented with useful hearing at the initiation of RT (p = 0.00062). Actuarial hearing preservation without the diagnosis of NF-2 was 98%. In cases with NF-2, the hearing preservation rate was 64%. Cranial nerve toxicity other than hearing impairment was rare. The rate of radiation induced toxicity to the trigeminal and facial nerve was 3.4% and 2.3%, respectively. Conclusion: Fractionated stereotactic radiotherapy is safe and efficacious for the treatment of AN, with mild toxicity with regard to hearing loss and cranial nerve function. FSRT might be considered as an equieffective treatment modality compared to neurosurgery and therefore represents an interesting alternative therapy for patients with AN

  20. [Operative treatment of painful neuromas].

    Science.gov (United States)

    Stokvis, Annemieke; Coert, J Henk

    2011-01-01

    3-5% of patients with traumatic or iatrogenic peripheral nerve injury develop a painful neuroma, especially following trauma of small cutaneous sensory nerve branches. Neuroma pain is difficult to treat and often leads to loss of function and reduction of quality of life. Patients with a painful neuroma present with spontaneous electric, shooting or burning pain, allodynia, hyperalgesia and cold intolerance. The diagnosis is based on the medical history and physical examination, supplemented by Tinel's test and a diagnostic nerve blockade. Lasting pain relief is possible by means of surgical neuroma treatment performed by a plastic surgeon. Surgical treatment consists of repair or denervation of the nerve with relocation of the nerve stump in bone or muscle tissue or a vein. Referral of neuroma patients without delay to a plastic surgeon or multidisciplinary consultation is important, because the symptoms become increasingly difficult to treat over time. 3-5% of patients with traumatic or iatrogenic peripheral nerve injury develop a painful neuroma, especially following trauma of small cutaneous sensory nerve branches. Neuroma pain is difficult to treat and often leads to loss of function and reduction of quality of life. Patients with a painful neuroma present with spontaneous electric, shooting or burning pain, allodynia, hyperalgesia and cold intolerance. The diagnosis is based on the medical history and physical examination, supplemented by Tinel's test and a diagnostic nerve blockade. Lasting pain relief is possible by means of surgical neuroma treatment performed by a plastic surgeon. Surgical treatment consists of repair or denervation of the nerve with relocation of the nerve stump in bone or muscle tissue or a vein. Referral of neuroma patients without delay to a plastic surgeon or multidisciplinary consultation is important, because the symptoms become increasingly difficult to treat over time.

  1. The effect of magnetic nanoparticles on the acoustic properties of tissue-mimicking agar-gel phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Józefczak, A., E-mail: aras@amu.edu.pl [Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University, Poznań (Poland); Kaczmarek, K. [Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University, Poznań (Poland); Kubovčíková, M. [Institute of Experimental Physics, Slovak Academy of Sciences, Košice (Slovakia); Rozynek, Z.; Hornowski, T. [Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University, Poznań (Poland)

    2017-06-01

    In ultrasonic hyperthermia, ultrasound-induced heating is achieved by the absorption of wave energy and its conversion into heat. The effectiveness of ultrasounds can be improved by using sonosensitisers that greatly attenuate ultrasonic waves and then dissipate the acquired energy in the form of heat. One possible candidate for such a sonosensitiser are superparamagnetic iron oxide nanoparticles. Here, we used magnetic nanoparticles embedded in a tissue-mimicking agar-gel matrix. Such tissue-mimicking phantoms possess acoustic properties similar to those of real tissues, and are used as a tool for performance testing and optimisation of medical ultrasound systems. In this work, we studied the effect of magnetic nanoparticles on the acoustic properties of agar-gel phantoms, including the attenuation of ultrasonic waves. - Highlights: • Ultrasonic insertion technique is used to study acoustic properties of agar-gel phantoms with and without magnetic particles. • The addition of magnetic nanoparticles improves effectiveness of ultrasound heating in agar phantoms. • Acoustics properties of a pure agar-gel phantom are altered by adding nanoparticles.

  2. Vestibular schwannoma (acoustic neuroma mimicking temporomandibular disorders: a case report Schwannoma vestibular (neurinoma do acústico imitando desordens temporomandibulares: um relato de caso

    Directory of Open Access Journals (Sweden)

    Maurício A. Bisi

    2006-12-01

    Full Text Available Approximately 6 to 16% of patients with trigeminal neuralgia symptoms present intracranial tumors, the most common being the vestibular schwannoma (acoustic neuroma. Some symptoms reported by patients include hearing loss, tinnitus, headaches, vertigo and trigeminal disturbances. An increased muscle response in the surrounding head and neck musculature may also be observed, which mimics signs and symptoms of temporomandibular disorders. In these cases, magnetic resonance imaging (MRI has proved to be a useful tool in tumor diagnosis. The differential diagnosis between myofascial and neuralgic pain is important, as both may present similar characteristics, while being of different origin, and demanding special treatment approaches. The purpose of this paper is to demonstrate the relationship among trigeminal neuralgia symptoms, intracranial tumors and temporomandibular dysfunction by presenting a clinical case.Aproximadamente 6 a 16% dos pacientes com sintomas de neuralgia trigeminal apresentam tumores intracranianos, sendo mais comum o schwannoma vestibular (neurinoma do acústico. Alguns sintomas relatados pelos pacientes são perda da audição, zumbido, dores de cabeça, vertigens e distúrbios trigeminais. Uma resposta muscular aumentada na musculatura associada da cabeça e do pescoço também pode ser observada, o que pode mimetizar sinais e sintomas de desordens temporomandibulares. Nestes casos é de grande valia o uso de imagem de ressonância magnética (IRM para detecção de tumores. É importante, também, a diferenciação de dores miofasciais e neurálgicas, pois ambas podem apresentar características semelhantes, mas com origens e tratamentos diferentes. O objetivo desse trabalho foi demonstrar através de relato de caso clínico a associação entre sintomas de neuralgia trigeminal, tumores intracranianos e disfunção temporomandibular.

  3. Swimming Training Reduces Neuroma Pain by Regulating Neurotrophins.

    Science.gov (United States)

    Tian, Jinge; Yu, Tingting; Xu, Yongming; Pu, Shaofeng; Lv, Yingying; Zhang, Xin; DU, Dongping

    2018-01-01

    Neuroma formation after peripheral nerve transection leads to severe neuropathic pain in amputees. Previous studies suggested that physical exercise could bring beneficial effect on alleviating neuropathic pain. However, the effect of exercise on neuroma pain still remained unclear. In addition, long-term exercise can affect the expression of neurotrophins (NT), such as nerve growth factor (NGF) and brain-derived neurotrophic factor (BDNF), which play key roles in nociceptor sensitization and nerve sprouting after nerve injury. Here, we investigated whether long-term swimming exercise could relieve neuroma pain by modulating NT expression. We used a tibial neuroma transposition (TNT) rat model to mimic neuroma pain. After TNT surgery, rats performed swimming exercise for 5 wk. Neuroma pain and tactile sensitivities were detected using von Frey filaments. Immunofluorescence was applied to analyze neuroma formation. NGF and BDNF expressions in peripheral neuroma, dorsal root ganglion, and the spinal cord were measured using enzyme-linked immunosorbent assay and Western blotting. TNT led to neuroma formation, induced neuroma pain, and mechanical allodynia in hind paw. Five-week swimming exercise inhibited neuroma formation and relieved mechanical allodynia in the hind paw and neuroma pain in the lateral ankle. The analgesic effect lasted for at least 1 wk, even when the exercise ceased. TNT elevated the expressions of BDNF and NGF in peripheral neuroma, dorsal root ganglion, and the spinal cord to different extents. Swimming also decreased the elevation of NT expression. Swimming exercise not only inhibits neuroma formation induced by nerve transection but also relieves pain behavior. These effects might be associated with the modulation of NT.

  4. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Back Learn more about ANA About ANA Mission, Vision & Values Shop ANA Leadership & Staff Annual Reports Acoustic ... 205-8211 info@ANAUSA.org About ANA Mission, Vision & Values Leadership & Staff Annual Reports Shop ANA Home ...

  5. Probabilistic Multiple-Bias Modeling Applied to the Canadian Data From the Interphone Study of Mobile Phone Use and Risk of Glioma, Meningioma, Acoustic Neuroma, and Parotid Gland Tumors.

    Science.gov (United States)

    Momoli, F; Siemiatycki, J; McBride, M L; Parent, M-É; Richardson, L; Bedard, D; Platt, R; Vrijheid, M; Cardis, E; Krewski, D

    2017-10-01

    We undertook a re-analysis of the Canadian data from the 13-country case-control Interphone Study (2001-2004), in which researchers evaluated the associations of mobile phone use with the risks of brain, acoustic neuroma, and parotid gland tumors. In the main publication of the multinational Interphone Study, investigators concluded that biases and errors prevented a causal interpretation. We applied a probabilistic multiple-bias model to address possible biases simultaneously, using validation data from billing records and nonparticipant questionnaires as information on recall error and selective participation. In our modeling, we sought to adjust for these sources of uncertainty and to facilitate interpretation. For glioma, when comparing those in the highest quartile of use (>558 lifetime hours) to those who were not regular users, the odds ratio was 2.0 (95% confidence interval: 1.2, 3.4). After adjustment for selection and recall biases, the odds ratio was 2.2 (95% limits: 1.3, 4.1). There was little evidence of an increase in the risk of meningioma, acoustic neuroma, or parotid gland tumors in relation to mobile phone use. Adjustments for selection and recall biases did not materially affect interpretation in our results from Canadian data. © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Distal anterior inferior cerebellar artery syndrome after acoustic neuroma surgery.

    Science.gov (United States)

    Hegarty, Joseph L; Jackler, Robert K; Rigby, Peter L; Pitts, Lawrence H; Cheung, Steven W

    2002-07-01

    To define a clinicopathologic syndrome associated with persistent cerebellar dysfunction after acoustic neuroma (AN) excision. Case series derived from radiographic and clinical chart review. Tertiary referral center. In 12 patients with AN, persistent cerebellar dysfunction developed after AN removal. Each case demonstrated abnormality in the ipsilateral cerebellar peduncle on postoperative magnetic resonance imaging. Cerebellar function and ambulatory status over the first postoperative year. On magnetic resonance imaging scans, the extent of cerebellar peduncle infarcts was variable. It ranged from focal brain injury (2 cm) spanning the full thickness of the peduncle. Peduncular infarcts were associated with large tumor size (average 3.8 cm, range 2.0-5.5 cm diameter). The long-term functional outcomes (>1 yr) varied. Dysmetria was unchanged or improved in over half of the patients (6 of 11 patients). Gait recovered to normal or to preoperative levels in 5 patients. In the 6 patients with persistent impaired mobility, 2 had mild gait disturbance, 3 required regular use of a cane, and 1 has been dependent on a walker. One patient had sustained mild motor weakness. Three of 11 patients remained dependent on others for activities of daily living. Peduncle injury most likely stems from interruption of distal branches of the anterior inferior cerebellar artery (AICA). These small vessels are intimately related to the capsule of the tumor and may supply both the neoplasm and the brain parenchyma. It has long been recognized that interruption of the proximal segment of the AICA results in severe injury to the pons, with devastating neurologic sequelae. A limited AICA syndrome caused by loss of its distal ramifications seems a more plausible explanation for peduncular infarction than either venous insufficiency or direct surgical trauma.

  7. SU-E-T-208: Incidence Cancer Risk From the Radiation Treatment for Acoustic Neuroma Patient

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D [Kyung Hee University International Med. Serv., Seoul (Korea, Republic of); Chung, W [Kyung Hee University Hospital at Gangdong, Seoul, Seoul (Korea, Republic of); Shin, D [Kyung Hee University Hospital, Seoul, Seoul (Korea, Republic of); Yoon, M [Korea University, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The present study aimed to compare the incidence risk of a secondary cancer from therapeutic doses in patients receiving intensitymodulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). Methods: Four acoustic neuroma patients were treated with IMRT, VMAT, or SRS. Their incidnece excess relative risk (ERR), excess absolute risk (EAR), and lifetime attributable risk (LAR) were estimated using the corresponding therapeutic doses measured at various organs by radio-photoluminescence glass dosimeters (RPLGD) placed inside a humanoid phantom. Results: When a prescription dose was delivered in the planning target volume of the 4 patients, the average organ equivalent doses (OED) at the thyroid, lung, normal liver, colon, bladder, prostate (or ovary), and rectum were measured. The OED decreased as the distance from the primary beam increased. The thyroid received the highest OED compared to other organs. A LAR were estimated that more than 0.03% of AN patients would get radiation-induced cancer. Conclusion: The tyroid was highest radiation-induced cancer risk after radiation treatment for AN. We found that LAR can be increased by the transmitted dose from the primary beam. No modality-specific difference in radiation-induced cancer risk was observed in our study.

  8. Morton neuroma: MRI diagnostic value

    International Nuclear Information System (INIS)

    Yelin, Enrique G.; Aparicio, Rocio; Dutto, Santiago; Rodriguez Lucero, Javier

    2004-01-01

    Objective: To evaluate the diagnostic value of MRI in Morton's Neuroma (MN). Material and methods: 23 patients with clinical diagnosis of MN were examined under two different protocols, with a 1.5 T Magnet. 1) T1, FSET2, FIR, T1 with contrast enhancement and fat suppression; 2) T1, FSET2, FIR without contrast enhancement (i.v. Gadolinium). Results: In the first group MN was found in 7 patients. In the second group 14 patients were studied, 7 with positive MR for neuroma, and 9 with negative MR. 6 were true-negative and 3 were false-negative. The Fisher Test between both groups was p < 0.05. Conclusion: MRI is effective for the diagnosis of Morton neuroma. The use of gadolinium and fat suppression significantly improved the detection of Morton neuroma, allowing better measurements of the lesion. These findings do not correlate with previous papers that do not encourage the use of i.v. Gadolinium. (author)

  9. SU-F-T-611: Critical Analysis and Efficacy of Linac Based (Beam Modulator) and Cyberknife Treatment Plans for Acoustic Neuroma/schwannoma

    International Nuclear Information System (INIS)

    KP, Karrthick; Kataria, T; Thiyagarajan, R; Selvan, T; Abhishek, A

    2016-01-01

    Purpose: To study the critical analysis and efficacy of Linac and Cyberknife (CK) treatment plans for acoustic neuroma/schwannoma. Methods: Twelve of acoustic neuroma/schwannoma patients were taken for these study that. Treatment plans were generated in Multiplan treatment planning system (TPS) for CK using 5,7.5 and 10mm diameter collimators. Target volumes were in the range of 0.280 cc to 9.256 cc. Prescription dose (Rx) ranges from 1150cGy to 1950cGy delivered over 1 to 3 Fractions. For same patients stereotactic Volumetric modulated arc plans were generated using Elekta Linac with MLC thickness of 4mm in Monaco TPS. Appropriate calculation algorithms and grid size were used with same Rx and organ at risk (OAR) constrains for both Linac and CK plans. Treatment plans were developed to achieve at least 95% of the target volume to receive the Rx. The dosimetric indices such as conformity index (CI), coverage, OAR dose and volume receiving 50% of Rx (V50%) were used to evaluate the plans. Results: Target volumes ranges from 0.280 cc to 3.5cc shows the CI of 1.16±0.109 and 1.53±0.360 for cyberknife and Linac plans respectively. For small volume targets, the OARs were well spared in CK plans. There are no significant differences in CI and OAR doses were observed between CK and Linac plans that have the target volume >3.5 cc. Perhaps the V50% were lesser in CK plans, and found to be 12.8± 8.4 and 22.8 ± 15.0 for CK and Linac respectively. Conclusion: The analysis shows the importance of collimator size for small volume targets. The target volumes >3.5 cc can be treated in Linac as comparable with CK. For targets <3.5cc CK plans showed superior plan quality with better CI and OAR sparing than the Linac based plans. Further studies may require evaluating the clinical advantage of CK robotic system.

  10. Occupation and risk of glioma, meningioma and acoustic neuroma: results from a German case-control study (interphone study group, Germany)

    DEFF Research Database (Denmark)

    Samkange-Zeeb, F; Schlehofer, B; Schüz, J

    2010-01-01

    /electronic and transport, and the risk of glioma, meningioma and acoustic neuroma. METHODS: In a population-based case-control study involving a total of 844 cases and 1688 controls conducted from 2000 to 2003, detailed information on life-long job histories was collected during personal interviews and used to create job...... calendars for each participant. Job title, job activity, job number, and the starting and ending dates of the activity were recorded for all activities with duration of at least 1 year. Reported occupational activities were coded according to the International Standard Classification of Occupations 1988...... (ISCO 88). For the analyses we focused on six a priori defined occupational sectors, namely chemical, metal, agricultural, construction, electrical/electronic and transport. Multiple conditional logistic regression analysis was used to estimate odds ratios and their 95% confidence intervals. RESULTS...

  11. Use of piezosurgery for internal auditory canal drilling in acoustic neuroma surgery.

    Science.gov (United States)

    Grauvogel, Juergen; Scheiwe, Christian; Kaminsky, Jan

    2011-10-01

    Piezosurgery is based on microvibrations generated by the piezoelectrical effect and has a selective bone-cutting ability with preservation of soft tissue. This study examined the applicability of Piezosurgery compared to rotating drills (RD) for internal auditory canal (IAC) opening in acoustic neuroma (AN) surgery. Piezosurgery was used in eight patients for IAC drilling in AN surgery. After exposition of the IAC and tumor, the posterior wall of the IAC was drilled using Piezosurgery instead of RD. Piezosurgery was evaluated with respect to practicability, safety, preciseness of bone cutting, preservation of cranial nerves, influences on neurophysiological monitoring, and facial nerve and hearing outcome. Piezosurgery was successfully used for selective bone cutting, while cranial nerves were structurally and functionally preserved, which could be measured by means of neuromonitoring. Piezosurgery guaranteed a safe and precise cut by removing bone layer by layer in a shaping way. Compared to RD, limited influence on neurophysiological monitoring attributable to Piezosurgery was noted, allowing for continuous neuromonitoring. No disadvantage due to microvibrations was noticed concerning hearing function. The angled tip showed better handling in right-sided than in left-sided tumors in the hands of a right-handed surgeon. The short, thick handpiece may be improved for more convenient handling. Piezosurgery is a safe tool for selective bone cutting for opening of the IAC with preservation of facial nerve and hearing function in AN surgery. Piezosurgery has the potential to replace RD for this indication because of its safe and precise bone-cutting properties.

  12. CT and MRI of haemorrhage into intracranial neuromas

    Energy Technology Data Exchange (ETDEWEB)

    Asari, S. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan)); Katayama, S. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan)); Itoh, T. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan)); Tsuchida, S. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan)); Ohmoto, T. (Dept. of Neurological Surgery, Okayama Univ. Medical School, Okayama City (Japan))

    1993-04-01

    Six patients with haemorrhage into intracranial neuromas were studied by computed tomography (CT) and magnetic resonance imaging (MRI) at 0.5 T with spin-echo pulse sequences. The nature of the tumour and the presence of a haematoma were confirmed by surgery and microscopic examination in all cases. Four neuromas arose from the acoustic nerves and two from the trigeminal. Four of the six patients suffered from sudden onset or rapid worsening of symptoms including headache, vertigo and/or hemifacial motor and sensory disturbances. CT in the acute stage revealed a hyperdense area or a fluid-fluid level (FFL). The hyperdense area disappeared on CT repeated in the chronic stage. On MRI in subacute and chronic stages the haemorrhage showed hyperintensity on both T1 and T2 weighting in five cases examined between 16 and 46 days after the onset, and isointensity on T1 weighting and an FFL on T2 weighting in one case examined 12 days after the onset of symptoms. A well-defined low intensity rim indicating prior haemorrhage was observed on T2-weighted images in three cases. MRI was more effectie than CT in detecting haemorrhage into the tumours and in staging it. (orig.)

  13. Use of mobile phones and cordless phones is associated with increased risk for glioma and acoustic neuroma.

    Science.gov (United States)

    Hardell, Lennart; Carlberg, Michael; Hansson Mild, Kjell

    2013-04-01

    The International Agency for Research on Cancer (IARC) at WHO evaluation of the carcinogenic effect of RF-EMF on humans took place during a 24-31 May 2011 meeting at Lyon in France. The Working Group consisted of 30 scientists and categorised the radiofrequency electromagnetic fields from mobile phones, and from other devices that emit similar non-ionising electromagnetic fields (RF-EMF), as Group 2B, i.e., a 'possible', human carcinogen. The decision on mobile phones was based mainly on the Hardell group of studies from Sweden and the IARC Interphone study. We give an overview of current epidemiological evidence for an increased risk for brain tumours including a meta-analysis of the Hardell group and Interphone results for mobile phone use. Results for cordless phones are lacking in Interphone. The meta-analysis gave for glioma in the most exposed part of the brain, the temporal lobe, odds ratio (OR)=1.71, 95% confidence interval (CI)=1.04-2.81 in the ≥10 years (>10 years in the Hardell group) latency group. Ipsilateral mobile phone use ≥1640h in total gave OR=2.29, 95% CI=1.56-3.37. The results for meningioma were OR=1.25, 95% CI=0.31-4.98 and OR=1.35, 95% CI=0.81-2.23, respectively. Regarding acoustic neuroma ipsilateral mobile phone use in the latency group ≥10 years gave OR=1.81, 95% CI=0.73-4.45. For ipsilateral cumulative use ≥1640h OR=2.55, 95% CI=1.50-4.40 was obtained. Also use of cordless phones increased the risk for glioma and acoustic neuroma in the Hardell group studies. Survival of patients with glioma was analysed in the Hardell group studies yielding in the >10 years latency period hazard ratio (HR)=1.2, 95% CI=1.002-1.5 for use of wireless phones. This increased HR was based on results for astrocytoma WHO grade IV (glioblastoma multiforme). Decreased HR was found for low-grade astrocytoma, WHO grades I-II, which might be caused by RF-EMF exposure leading to tumour-associated symptoms and earlier detection and surgery with better

  14. Ultrasonography and magnetic resonance imaging in the diagnosis of Morton's neuroma.

    Science.gov (United States)

    Fazal, Muhammad Ali; Khan, Ishrat; Thomas, Cherian

    2012-01-01

    Magnetic resonance imaging (MRI) and ultrasonography are used widely for the diagnosis of Morton's neuroma. The aim of this study was to assess the accuracy of these two modalities as diagnostic tools in Morton's neuroma. Fifty feet of 47 consecutive patients (39 women and 8 men; mean age, 46 years; age range, 36-64 years) who presented between January 1, 2005, and June 30, 2008, were included in the study. Twenty-five feet were investigated with ultrasonography and 25 with MRI. Morton's neuroma was confirmed surgically and histologically in all of the patients. A Student unpaired t test was applied. Twenty-two MRIs were diagnostic (sensitivity, 88%). Three patients with negative MRI findings underwent ultrasonography and were found to have a neuroma smaller than 5 mm. Twenty-four ultrasound scans demonstrated the neuroma (sensitivity, 96%), with five neuromas being smaller than 5 mm. Ultrasonography has a slightly higher sensitivity in the diagnosis of Morton's neuroma, particularly of neuromas smaller than 5 mm, and should be the preferred imaging modality in suspected cases, and MRI should be reserved for cases with equivocal diagnosis.

  15. An evidence-based case of acoustic/vestibular schwannoma

    Directory of Open Access Journals (Sweden)

    Girish Gupta

    2015-01-01

    Full Text Available A vestibular schwannoma, often called an acoustic neuroma/schwannoma, is a benign primary intracranial tumor of the myelin-forming cells of the vestibulo-cochlear nerve (8 th cranial nerve. This tumor arises from the Schwann cells responsible for the myelin sheath that helps keep peripheral nerves insulated. [1] Approximately, 3000 cases are diagnosed each year in the United States with a prevalence of about 1 in 100,000 worldwide. It comprises 5-10% of all intracranial neoplasms in adults. Incidence peaks in the fifth and sixth decades and both sexes are affected equally. Studies in Denmark published in 2004 show the incidence of 17.4/million. Most acoustic neuromas are diagnosed in patients between the ages of 30 and 60, and men and women appear to be affected equally. [2] The case illustrated here is a rare one of acoustic/vestibular schwannoma a surgical conditions, treated with Lycopodium, which produced improvement on both subjective and objective parameters.

  16. Palisaded encapsulated neuroma

    Directory of Open Access Journals (Sweden)

    Adesh S Manchanda

    2015-01-01

    Full Text Available Palisaded encapsulated neuroma (PEN is a benign cutaneous or mucosal neural tumor which, usually, presents as a solitary, firm, asymptomatic, papule or nodule showing striking predilection for the face. It occurs commonly in middle age, and there is no sex predilection. Oral PEN are not common, and these lesions must be distinguished from other peripheral nerve sheath tumors such as the neurofibroma, neurilemma (schwannoma, and traumatic neuroma. The major challenge in dealing with lesions of PEN is to avoid the misdiagnosis of neural tumors that may be associated with systemic syndromes such as neurofibromatosis and multiple endocrine neoplasia syndrome type 2B. Here, we present a case of benign PEN of the gingiva in the left anterior mandibular region, laying importance on immunohistochemical staining in diagnosing such lesions.

  17. A free vein graft cap influences neuroma formation after nerve transection.

    Science.gov (United States)

    Galeano, Mariarosaria; Manasseri, Benedetto; Risitano, Giovanni; Geuna, Stefano; Di Scipio, Federica; La Rosa, Paola; Delia, Gabriele; D'Alcontres, Francesco Stagno; Colonna, Michele R

    2009-01-01

    : Neuroma formation is a major problem in nerve surgery and consensus about its prevention has not been reached. It has been suggested that vein covering can reduce neuroma formation in transected nerves. In this article, the Authors propose an easy and novel method of covering by nerve stump capping with a free vein graft. : Neuroma-like lesions were created on the rat thigh sectioning the femoral nerve above its division in 16 animals. The proximal nerve stump was invaginated into the lumen of a 1.5 cm long femoral free vein graft on the right side, and the vein was closed on itself by microsurgical sutures to form a cap for the nerve stump. On the left side acting as the control neuroma, the nerve was cut and left uncovered. Histological and immunohistochemical assessment was used to quantify the degree of neuroma formation. : Significant differences were found in both neuroma size and axon-glia organization between the treated and control sides indicating that free vein graft capping reduced neuroma formation in comparison to uncovered nerve stumps. : Our results confirm that vein-covering of a transected nerve stump can be effective in reducing neuroma formation. Moreover, unlike previous works that buried the nerve into an adjacent vein left in place, our experiments showed that also the use of a free vein graft cap can hinder neuroma formation. Although translation of rat experiments to the clinics should be dealt with caution, our data suggest a careful clinical use of the technique. (c) 2009 Wiley-Liss, Inc. Microsurgery, 2009.

  18. Validation of the Penn Acoustic Neuroma Quality-of-Life Scale (PANQOL) for Spanish-Speaking Patients.

    Science.gov (United States)

    Medina, Maria Del Mar; Carrillo, Alvaro; Polo, Ruben; Fernandez, Borja; Alonso, Daniel; Vaca, Miguel; Cordero, Adela; Perez, Cecilia; Muriel, Alfonso; Cobeta, Ignacio

    2017-04-01

    Objective To perform translation, cross-cultural adaptation, and validation of the Penn Acoustic Neuroma Quality-of-Life Scale (PANQOL) to the Spanish language. Study Design Prospective study. Setting Tertiary neurotologic referral center. Subjects and Methods PANQOL was translated and translated back, and a pretest trial was performed. The study included 27 individuals diagnosed with vestibular schwannoma. Inclusion criteria were adults with untreated vestibular schwannoma, diagnosed in the past 12 months. Feasibility, internal consistency, test-retest reliability, construct validity, and ceiling and floor effects were assessed for the present study. Results The mean overall score of the PANQOL was 69.21 (0-100 scale, lowest to highest quality of life). Cronbach's α was 0.87. Intraclass correlation coefficient was performed for each item, with an overall score of 0.92. The κ coefficient scores were between moderate and almost perfect in more than 92% of patients. Anxiety and energy domains of the PANQOL were correlated with both physical and mental components of the SF-12. Hearing, balance, and pain domains were correlated with the SF-12 physical component. Facial and general domains were not significantly correlated with any component of the SF-12. Furthermore, the overall score of the PANQOL was correlated with the physical component of the SF-12. Conclusion Feasibility, internal consistency, reliability, and construct validity outcomes in the current study support the validity of the Spanish version of the PANQOL.

  19. [Treatment of painful neuromas via end-to-side neurorraphy].

    Science.gov (United States)

    Aszmann, O C; Moser, V; Frey, M

    2010-08-01

    Management of the painful neuroma has been subject to controversy since the earliest descriptions of this disabling problem. Today, treatment is limited to resection of the neuroma and implantation of the nerve in a muscle at a location where it is safe from irritation and trauma. This however is not attainable in many cases and it is our clinical experience, that nerves without a target remain a source of constant discomfort and pain. Recently we reported of the feasibility of neuroma prevention through end-to-side neurorraphy into adjacent sensory and/or motor nerves to provide a target for axons deprived of their endorgan. Here we report of our first clinical experience with this method in sixteen patients with longstanding upper and lower extremity neuromas. 16 patients were included in this study. All had neuromas of different sensory nerves of both the upper and lower extremity. 11 were of iatrogenic origin, 5 were caused by different traumas. 8 had previous attempts to surgically treat the neuroma. Finally, all were treated by end-to-side neurorraphy into adjacent nerves. Postoperatively quantitative sensorymotor testing was performed to evaluate possible changes of nerve function of the recipient nerves. Pain was evaluated by visual analogue score and changes in pain medication. In no patient a sensory or motor deficit or painful sensations were induced in the target area of the recipient nerve. Some had dysaesthesias for about 6 months, which finally subsided. All but 1 patient improved in their symptoms at a follow-up of more than 2 years. Previous experimental work and present clinical results suggest that axons of a severed peripheral nerve that are provided with a pathway and target through an end-to-side coaptation will either be pruned or establish some type of end-organ contact so that a neuroma can be prevented without inducing sensory or motor dysfunctions in the recipient nerve. Georg Thieme Verlag KG Stuttgart New York.

  20. A quantitative evaluation of gross versus histologic neuroma formation in a rabbit forelimb amputation model: potential implications for the operative treatment and study of neuromas

    Directory of Open Access Journals (Sweden)

    Kuiken Todd A

    2011-10-01

    Full Text Available Abstract Background Surgical treatment of neuromas involves excision of neuromas proximally to the level of grossly "normal" fascicles; however, proximal changes at the axonal level may have both functional and therapeutic implications with regard to amputated nerves. In order to better understand the retrograde "zone of injury" that occurs after nerve transection, we investigated the gross and histologic changes in transected nerves using a rabbit forelimb amputation model. Methods Four New Zealand White rabbits underwent a forelimb amputation with transection and preservation of the median, radial, and ulnar nerves. After 8 weeks, serial sections of the amputated nerves were then obtained in a distal-to-proximal direction toward the brachial plexus. Quantitative histomorphometric analysis was performed on all nerve specimens. Results All nerves demonstrated statistically significant increases in nerve cross-sectional area between treatment and control limbs at the distal nerve end, but these differences were not observed 10 mm more proximal to the neuroma bulb. At the axonal level, an increased number of myelinated fibers were seen at the distal end of all amputated nerves. The number of myelinated fibers progressively decreased in proximal sections, normalizing at 15 mm proximally, or the level of the brachial plexus. The cross-sectional area of myelinated fibers was significantly decreased in all sections of the treatment nerves, indicating that atrophic axonal changes proceed proximally at least to the level of the brachial plexus. Conclusions Morphologic changes at the axonal level extend beyond the region of gross neuroma formation in a distal-to-proximal fashion after nerve transection. This discrepancy between gross and histologic neuromas signifies the need for improved standardization among neuroma models, while also providing a fresh perspective on how we should view neuromas during peripheral nerve surgery.

  1. Ultrasound-Guided Hyaluronic Acid Injection for the Management of Morton's Neuroma.

    Science.gov (United States)

    Lee, Kang; Hwang, Il-Yeong; Ryu, Chang Hyun; Lee, Jae Woo; Kang, Seung Woo

    2018-02-01

    Morton's neuroma is one of the common causes of forefoot pain. In the present study, hyaluronic acid injection was performed on patients to determine the efficacy and adverse effects of hyaluronic acid in management of Morton's neuroma. Eighty-three patients with Morton's neuroma in their third intermetatarsal space with definite Mulder's click were included in the study. Those with severe forefoot deformities such as forefoot cavus or hallux valgus on plain X-rays were excluded. Ultrasound-guided hyaluronic acid injections were performed on all patients weekly for 3 weeks. Pain during walking using visual analogue scale (VAS) and AOFAS Forefoot Scale were prospectively evaluated preinjection, and at 2, 4, 6, 12 months postinjection. Significant improvement in VAS and AOFAS Forefoot Scale were seen overall at 2 months after hyaluronic acid injections ( P hyaluronic injection was clinically effective for pain relief and functional improvement for at least 12 months in patients with Morton's neuroma. However, numbness associated with Morton's neuroma should be addressed more cautiously since it may persist without much improvement. Level IV, retrospective case series.

  2. Fractionated Stereotactic Radiotherapy in the Treatment of Vestibular Schwannoma (Acoustic Neuroma): Predicting the Risk of Hydrocephalus

    International Nuclear Information System (INIS)

    Powell, Ceri; Micallef, Caroline; Gonsalves, Adam; Wharram, Bev; Ashley, Sue; Brada, Michael

    2011-01-01

    Purpose: To determine the incidence and predictive factors for the development of hydrocephalus in patients with acoustic neuromas (AN) treated with fractionated stereotactic radiotherapy. Patients and Methods: Seventy-two patients with AN were treated with fractionated stereotactic radiotherapy between 1998 and 2007 (45-50 Gy in 25-30 fractions over 5 to 6 weeks). The pretreatment MRI scan was assessed for tumor characteristics and anatomic distortion independently of subsequent outcome and correlated with the risk of hydrocephalus. Results: At a median follow-up of 49 months (range, 1-120 months), 5-year event-free survival was 95%. Eight patients (11%) developed hydrocephalus within 19 months of radiotherapy, which was successfully treated. On univariate analysis, pretreatment factors predictive of hydrocephalus were maximum diameter (p = 0.005), proximity to midline (p = 0.009), displacement of the fourth ventricle (p = 0.02), partial effacement of the fourth ventricle (p < 0.001), contact with the medulla (p = 0.005), and more brainstem structures (p = 0.004). On multivariate analysis, after adjusting for fourth ventricular effacement, no other variables remained independently associated with hydrocephalus formation. Conclusions: Fractionated stereotactic radiotherapy results in excellent tumor control of AN, albeit with a risk of developing hydrocephalus. Patients at high risk, identified as those with larger tumors with partial effacement of the fourth ventricle before treatment, should be monitored more closely during follow-up. It would also be preferable to offer treatment to patients with progressive AN while the risk of hydrocephalus is low, before the development of marked distortion of fourth ventricle before tumor diameter significantly exceeds 2 cm.

  3. Ultrasonographic features of traumatic neuromas in breast cancer patients after mastectomy

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Hwa Sung; Kim, Young Seon [Dept. of Radiology, Yeungnam University College of Medicine, Daegu (Korea, Republic of)

    2017-01-15

    The purpose of this study was to evaluate the ultrasonographic (US) features of traumatic neuromas in breast cancer patients after mastectomy. This study was performed with approval from our Institutional Review Board, and the requirement for informed consent was waived. Six traumatic neuromas in five patients were included in this study. The US findings of traumatic neuromas were evaluated retrospectively by two radiologists according to the Breast Imaging-Reporting and Data System (BI-RADS) lexicon. The final assessment was also recorded. On US, all six lesions presented as a mass within the pectoralis muscle layer (mean size, 4.8 mm; range, 3.9 to 5.5 mm). Of the six masses, four had an oval shape with a circumscribed margin, and two had an irregular shape and an indistinct margin. They were all hypoechoic. Two lesions showed a non-parallel orientation. On color Doppler examinations, two lesions showed internal vascularity. Strain elastography was performed for four neuromas, resulting in scores of 1 (n=1), 4 (n=2), and 5 (n=1). The final assessment categories were BI-RADS 3 (n=2), 4A (n=2), and 4B (n=2). On US, an oval shape, circumscribed margin, parallel orientation, and hypoechogenicity were the most frequent features of traumatic neuromas in breast cancer patients after mastectomy. Neuromas may show increased vascularity on color Doppler imaging and present as a hard mass on elastography.

  4. Ultrasonographic features of traumatic neuromas in breast cancer patients after mastectomy

    Directory of Open Access Journals (Sweden)

    Hwa Sung Sung

    2017-01-01

    Full Text Available Purpose The purpose of this study was to evaluate the ultrasonographic (US features of traumatic neuromas in breast cancer patients after mastectomy. Methods This study was performed with approval from our Institutional Review Board, and the requirement for informed consent was waived. Six traumatic neuromas in five patients were included in this study. The US findings of traumatic neuromas were evaluated retrospectively by two radiologists according to the Breast Imaging-Reporting and Data System (BI-RADS lexicon. The final assessment was also recorded. Results On US, all six lesions presented as a mass within the pectoralis muscle layer (mean size, 4.8 mm; range, 3.9 to 5.5 mm. Of the six masses, four had an oval shape with a circumscribed margin, and two had an irregular shape and an indistinct margin. They were all hypoechoic. Two lesions showed a non-parallel orientation. On color Doppler examinations, two lesions showed internal vascularity. Strain elastography was performed for four neuromas, resulting in scores of 1 (n=1, 4 (n=2, and 5 (n=1. The final assessment categories were BI-RADS 3 (n=2, 4A (n=2, and 4B (n=2. Conclusion On US, an oval shape, circumscribed margin, parallel orientation, and hypoechogenicity were the most frequent features of traumatic neuromas in breast cancer patients after mastectomy. Neuromas may show increased vascularity on color Doppler imaging and present as a hard mass on elastography.

  5. Hypofractionated stereotactic radiotherapy of acoustic neuroma. Volume changes and hearing results after 89-month median follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kranzinger, Manfred; Fastner, Gerd [Paracelsus Medical University Clinics (PMU), University Clinic of Radiotherapy and Radio-Oncology, Salzburg County Hospital, Salzburg (Austria); Zehentmayr, Franz; Sedlmayer, Felix [Paracelsus Medical University Clinics (PMU), University Clinic of Radiotherapy and Radio-Oncology, Salzburg County Hospital, Salzburg (Austria); Salzburg County Hospital, Paracelsus Medical University Clinics, radART - Institute for Research and Development on Advanced Radiation Technologies, Salzburg (Austria); Oberascher, Gerhard [Paracelsus Medical University Clinics (PMU), University Clinic of Ear, Nose and Throat Diseases, Salzburg County Hospital, Salzburg (Austria); Merz, Florian; Rahim, Hassan [Salzburg County Hospital, Paracelsus Medical University Clinics, Medical Radiation Protection Unit, Salzburg (Austria); Nairz, Olaf [Clinic Bad Trissl, Oberaudorf (Germany)

    2014-09-15

    The goal of this work was to evaluate toxicity and local control following hypofractionated stereotactic radiation treatment with special focus on changes in tumor volume and hearing capacity. In all, 29 patients with unilateral acoustic neuroma were treated between 2001 and 2007 within a prospective radiation protocol (7 x 4 Gy ICRU dose). Median tumor volume was 0.9 ml. Follow-up started at 6 months and was repeated annually with MRI volumetry and audiometry. Hearing preservation was defined as preservation of Class A/B hearing according to the guidelines of the American Academy of Otolaryngology (1995). No patient had any intervention after a median imaging follow-up of 89.5 months, one patient showed radiological progression. Transient increase of tumor volume developed in 17/29 patients, whereas 22/29 patients (75.9 %) presented with a volume reduction at last follow-up. A total of 21 patients were eligible for hearing evaluation. Mean pure tone average (PTA) deteriorated from 39.3 to 65.9 dB and mean speech discrimination score (SDS) dropped from 74.3 to 38.1 %. The 5-year actuarial Class A/B hearing preservation rate was 50.0 ± 14.4 %. Radiation increases only minimally, if at all, the hearing deterioration which emerges by observation alone. Presbyacusis is not responsible for this deterioration. Transient tumor enlargement is common. Today radiation of small- and medium-sized acoustic neuroma can be performed with different highly conformal techniques as fractionated treatment or single low-dose radiosurgery with equal results regarding tumor control, hearing preservation, and side effects. Hypofractionation is more comfortable for the patient than conventional regimens and represents a serious alternative to frameless radiosurgery. (orig.) [German] Ziel der Studie war die Evaluierung der Toxizitaet und der lokalen Tumorkontrolle einer hypofraktionierten stereotaktischen Bestrahlung mit besonderem Augenmerk auf Veraenderungen von Tumorvolumen und

  6. Biliary stricture due to neuroma after an innocent blunt abdominal trauma.

    Science.gov (United States)

    Katsinelos, P; Dimiropoulos, S; Galanis, I; Tsolkas, P; Paroutoglu, G; Arvaniti, M; Katsiba, D; Baltaglannis, S; Pilpilidis, I; Papagiannis, A; Vaslliadis, I

    2002-10-01

    A traumatic neuroma of the biliary tract is rarely associated with biliary obstruction. However, when it arises in the common bile duct (CBD) and is associated with obstructive jaundice, it is difficult to distinguish it from bile duct cancer. We describe a patient who developed obstructive jaundice and itching, due to CBD stricture, 8 years after innocent blunt abdominal trauma. The stricture was resected and hepatico-jejunal anastomosis was performed. Histological examination revealed a traumatic neuroma and a fibrous scar around the common bile duct. Symptoms disappeared following surgical removal of the lesion. Blunt abdominal injury may cause the late onset of a fibrous scar and traumatic neuroma in the common bile duct. To our knowledge, a traumatic neuroma of the biliary tract after blunt abdominal trauma has not been reported previously. We review the clinical picture of this relatively rare problem, along with its diagnosis, pathogenesis and treatment.

  7. Intraoperative facial motor evoked potentials monitoring with transcranial electrical stimulation for preservation of facial nerve function in patients with large acoustic neuroma

    Institute of Scientific and Technical Information of China (English)

    LIU Bai-yun; TIAN Yong-ji; LIU Wen; LIU Shu-ling; QIAO Hui; ZHANG Jun-ting; JIA Gui-jun

    2007-01-01

    Background Although various monitoring techniques have been used routinely in the treatment of the lesions in the skull base, iatrogenic facial paresis or paralysis remains a significant clinical problem. The aim of this study was to investigate the effect of intraoperative facial motor evoked potentials monitoring with transcranial electrical stimulation on preservation of facial nerve function.Method From January to November 2005, 19 patients with large acoustic neuroma were treated using intraoperative facial motor evoked potentials monitoring with transcranial electrical stimulation (TCEMEP) for preservation of facial nerve function. The relationship between the decrease of MEP amplitude after tumor removal and the postoperative function of the facial nerve was analyzed.Results MEP amplitude decreased more than 75% in 11 patients, of which 6 presented significant facial paralysis (H-B grade 3), and 5 had mild facial paralysis (H-B grade 2). In the other 8 patients, whose MEP amplitude decreased less than 75%, 1 experienced significant facial paralysis, 5 had mild facial paralysis, and 2 were normal.Conclusions Intraoperative TCEMEP can be used to predict postoperative function of the facial nerve. The decreased MEP amplitude above 75 % is an alarm point for possible severe facial paralysis.

  8. Multistep translation and cultural adaptation of the Penn acoustic neuroma quality-of-life scale for German-speaking patients.

    Science.gov (United States)

    Kristin, Julia; Glaas, Marcel Fabian; Stenin, Igor; Albrecht, Angelika; Klenzner, Thomas; Schipper, Jörg; Eysel-Gosepath, Katrin

    2017-11-01

    Monitoring the health-related quality of life (HRQOL) for patients with vestibular schwannoma (VS) has garnered increasing interest. In German-speaking countries, there is no disease-specific questionnaire available similar to the "Penn Acoustic Neuroma Quality-of-life Scale" (PANQOL). We translated the PANQOL for German-speaking patients based on a multistep protocol that included not only a forward-backward translation but also linguistic and sociocultural adaptations. The process consists of translation, synthesis, back translation, review by an expert committee, administration of the prefinal version to our patients, submission and appraisal of all written documents by our research team. The required multidisciplinary team for translation comprised head and neck surgeons, language professionals (German and English), a professional translator, and bilingual participants. A total of 123 patients with VS underwent microsurgical procedures via different approaches at our clinic between January 2007 and January 2017. Among these, 72 patients who underwent the translabyrinthine approach participated in the testing of the German-translated PANQOL. The first German version of the PANQOL questionnaire was created by a multistep translation process. The responses indicate that the questionnaire is simple to administer and applicable to our patients. The use of a multistep process to translate quality-of-life questionnaires is complex and time-consuming. However, this process was performed properly and resulted in a version of the PANQOL for assessing the quality of life of German-speaking patients with VS.

  9. Acoustic transparency and slow sound using detuned acoustic resonators

    DEFF Research Database (Denmark)

    Santillan, Arturo Orozco; Bozhevolnyi, Sergey I.

    2011-01-01

    We demonstrate that the phenomenon of acoustic transparency and slowsound propagation can be realized with detuned acoustic resonators (DAR), mimicking thereby the effect of electromagnetically induced transparency (EIT) in atomic physics. Sound propagation in a pipe with a series of side...

  10. Traumatic facial nerve neuroma with facial palsy presenting in infancy.

    Science.gov (United States)

    Clark, James H; Burger, Peter C; Boahene, Derek Kofi; Niparko, John K

    2010-07-01

    To describe the management of traumatic neuroma of the facial nerve in a child and literature review. Sixteen-month-old male subject. Radiological imaging and surgery. Facial nerve function. The patient presented at 16 months with a right facial palsy and was found to have a right facial nerve traumatic neuroma. A transmastoid, middle fossa resection of the right facial nerve lesion was undertaken with a successful facial nerve-to-hypoglossal nerve anastomosis. The facial palsy improved postoperatively. A traumatic neuroma should be considered in an infant who presents with facial palsy, even in the absence of an obvious history of trauma. The treatment of such lesion is complex in any age group but especially in young children. Symptoms, age, lesion size, growth rate, and facial nerve function determine the appropriate management.

  11. Temperature dependence of acoustic harmonics generated by nonlinear ultrasound beam propagation in ex vivo tissue and tissue-mimicking phantoms.

    Science.gov (United States)

    Maraghechi, Borna; Kolios, Michael C; Tavakkoli, Jahan

    2015-01-01

    Hyperthermia is a cancer treatment technique that could be delivered as a stand-alone modality or in conjunction with chemotherapy or radiation therapy. Noninvasive and real-time temperature monitoring of the heated tissue improves the efficacy and safety of the treatment. A temperature-sensitive acoustic parameter is required for ultrasound-based thermometry. In this paper the amplitude and the energy of the acoustic harmonics of the ultrasound backscattered signal are proposed as suitable parameters for noninvasive ultrasound thermometry. A commercial high frequency ultrasound imaging system was used to generate and detect acoustic harmonics in tissue-mimicking gel phantoms and ex vivo bovine muscle tissues. The pressure amplitude and the energy content of the backscattered fundamental frequency (p1 and E1), the second (p2 and E2) and the third (p3 and E3) harmonics were detected in pulse-echo mode. Temperature was increased from 26° to 46 °C uniformly through both samples. The amplitude and the energy content of the harmonics and their ratio were measured and analysed as a function of temperature. The average p1, p2 and p3 increased by 69%, 100% and 283%, respectively as the temperature was elevated from 26° to 46 °C in tissue samples. In the same experiment the average E1, E2 and E3 increased by 163%, 281% and 2257%, respectively. A similar trend was observed in tissue-mimicking gel phantoms. The findings suggest that the harmonics generated due to nonlinear ultrasound beam propagation are highly sensitive to temperature and could potentially be used for noninvasive ultrasound tissue thermometry.

  12. Tissue-mimicking bladder wall phantoms for evaluating acoustic radiation force-optical coherence elastography systems.

    Science.gov (United States)

    Ejofodomi, O'tega A; Zderic, Vesna; Zara, Jason M

    2010-04-01

    Acoustic radiation force-optical coherence elastography (ARF-OCE) systems are novel imaging systems that have the potential to simultaneously quantify and characterize the optical and mechanical properties of in vivo tissues. This article presents the construction of bladder wall phantoms for use in ARF-OCE systems. Mechanical, acoustic, and optical properties are reported and compared to published values for the urinary bladder. The phantom consisted of 0.2000 +/- 0.0089 and 6.0000 +/- 0.2830 microm polystyrene microspheres (Polysciences Inc., Warrington, PA, Catalog Nos. 07304 and 07312), 7.5 +/- 1.5 microm copolymer microspheres composed of acrylonitrile and vinylidene chloride, (Expancel, Duluth, GA, Catalog No. 461 DU 20), and bovine serum albumin within a gelatin matrix. Young's modulus was measured by successive compression of the phantom and obtaining the slope of the resulting force-displacement data. Acoustic measurements were performed using the transmission method. The phantoms were submerged in a water bath and placed between transmitting and receiving 13 mm diameter unfocused transducers operating at a frequency of 3.5 MHz. A MATLAB algorithm to extract the optical scattering coefficient from optical coherence tomography (OCT) images of the phantom was used. The phantoms possess a Young's modulus of 17.12 +/- 2.72 kPa, a mass density of 1.05 +/- 0.02 g/cm3, an acoustic attenuation coefficient of 0.66 +/- 0.08 dB/cm/MHz, a speed of sound of 1591 +/- 8.76 m/s, and an optical scattering coefficient of 1.80 +/- 0.23 mm(-1). Ultrasound and OCT images of the bladder wall phantom are presented. A material that mimics the mechanical, optical, and acoustic properties of healthy bladder wall has been developed. This tissue-mimicking bladder wall phantom was developed as a control tool to investigate the feasibility of using ARF-OCE to detect the mechanical and optical changes that may be indicative of the onset or development of cancer in the urinary bladder

  13. Endobronchial neurogenic tumor: A combination of traumatic neuroma and neurofibroma

    Directory of Open Access Journals (Sweden)

    Amit Tandon

    2017-01-01

    Full Text Available Traumatic neuromas are uncommon and benign lesions arising from a peripheral nerve injury during surgery. Here we describe a case with histopathologic features of both a traumatic neuroma and neurofibroma in a patient without integumentary physical exam findings nor prior surgical history. A 54 year old male was admitted for surgical debridement of a foot ulcer. During pre-operative evaluation and review of imaging multiple CT scans revealed a stable, 4 mm endobronchial lesion in the left lower lobe. Given history of nicotine abuse, bronchoscopy was performed. Bronchoscopy showed a pearly, polypoid lesion. Histopathological results showed strong positivity for S-100 protein and spindle cell proliferation. Repeat CT chest showed no new lesions in the bronchial tree. The rarity of this case is noted not only by the limited number of bronchial neurogenic tumors, but the combined features in this case of a traumatic neuroma and neurofibroma which has not been described.

  14. Penile Traumatic Neuroma: A Late Complication of Penile Dorsal Neurotomy to Treat Premature Ejaculation

    Directory of Open Access Journals (Sweden)

    Hyun Jun Park

    2016-09-01

    Conclusion: The main complications of SDN are recurrence of premature ejaculation, pain or paresthesia on the glans penis, and erectile dysfunction. However, no traumatic neuroma has been reported as a complication. We report that a traumatic neuroma can occur after SDN.

  15. Filippo Civinini (1805-1844 and the discovery of plantar neuroma

    Directory of Open Access Journals (Sweden)

    P. Marson

    2011-09-01

    Full Text Available Pathological abnormality (neuroma related to the painful foot condition commonly called “Morton’s metatarsalgia” was first observed in 1835 by Filippo Civinini (1805-1844 of Pistoia, in course of a cadaverous dissection, and clearly described in the anatomic letter entitled “Su un nervoso gangliare rigonfiamento alla pianta del piede” (“On the neural gangliar swelling of the foot sole”. In this study a brief review on the history of Morton’s metatarsalgia is carried out, and the importance of Civinini in the discovery of the neuroma of the III intermetatarsal web is underlined.

  16. Palisaded Encapsulated (Solitary Circumscribed) Neuroma of the Buccal Mucosa: a Rare Case.

    Science.gov (United States)

    Atarbashi-Moghadam, Saede; Lotfi, Ali; Salehi Zalani, Saman; Mokhtari, Sepideh

    2017-12-01

    The rarity of oral soft tissue spindle cell tumors combined with overlapping microscopic patterns can make challenges in their diagnosis and treatment. Oral cavity palisaded encapsulated neuroma is an uncommon lesion which occurs often on the hard palate. It is essential for oral pathologists to be familiar with its histopathology of this lesion is essential since many lesions are probably diagnosed microscopically as neurofibroma or schwannoma. Here, we report a case of oral palisaded encapsulated (solitary circumscribed) neuroma in an unusual site.

  17. Recurrent neuroma formation after lateral arm free flap coverage with neurorraphy to the posteroantebrachial nerve.

    Science.gov (United States)

    Peterson, Steven L; Gordon, Michael J

    2004-09-01

    We report a patient with previous wrist trauma and development of a symptomatic neuroma of the palmar cutaneous branch of the median nerve. The patient had previously been successfully treated with lateral arm free flap coverage with neurorrhaphy to a segment of the posteroantebrachial cutaneous nerve carried with the flap. Two years following this procedure the patient experienced re-onset of symptoms prompting surgical exploration of the area. At the time of operation a recurrent neuroma was found at the free distal terminus of the transferred posteroantebrachial cutaneous nerve. The neuroma was repositioned into the distal radius via a burr hole with relief of symptoms.

  18. Hearing preservation after low dose linac radiosurgery for acoustic neuroma depends on initial hearing and time

    International Nuclear Information System (INIS)

    Roos, Daniel E.; Potter, Andrew E.; Zacest, Andrew C.

    2011-01-01

    Purpose: To assess long term outcomes and factors determining hearing preservation after low dose linac stereotactic radiosurgery (SRS) for acoustic neuroma (AN) at the Royal Adelaide Hospital using prospectively collected data. Material and methods: Between 1994 and 2010, 102 patients had SRS for AN. Five patients had neurofibromatosis type 2, six sporadic cases had relapsed after surgery, and the remaining 91 sporadic cases had primary SRS. Dose was 12 or 14 Gy. Sustained changes ⩾ 2 mm in any diameter were deemed significant, and useful hearing was defined as inter-aural pure tone average (PTA) ⩽ 50 dB. Possible prognostic factors for hearing retention were tested by dividing the patients at pre-specified cutpoints: age (60 years), maximum tumour diameter (20 mm), initial PTA (20 dB) and dose (12 vs 14 Gy). Results: Eighty-four of the 91 sporadic primary SRS cases were evaluable for tumour control with at least one post-treatment MRI. Their median follow-up was 65 mo (range 10–184 mo). Eighty-two (97.6%) were controlled, the remaining two requiring salvage surgery for progression at 5.75 and 9.75 years. Also, one of the post-operative cases required surgery at 2.1 years after SRS. For the 50 sporadic primary SRS patients with initially useful hearing, median age was 56 (range 21–76), median initial PTA 16 dB (range −11 to +45 dB) and median tumour diameter 21 mm (range 10–33 mm). Four received 14 Gy, the rest 12 Gy. After SRS, 19 patients (38%) retained useful hearing. The Kaplan–Meier estimated preservation rate at 5 years was 50% (95% CI 36–64%) but by 10 years, this had fallen to 23% (95% CI 12–41%). On univariate analysis, the only significant factor was initial PTA (P < 0.0001). The estimated risk of hearing loss after SRS for patients with initial PTA ⩾ 20 dB was 5.0 (95% CI 2.2–11.2) times that with PTA < 20 dB. Conclusions: Tumour control was excellent (99/102 = 97% freedom from surgical salvage). Hearing preservation was strongly

  19. Anti-sound and Acoustical Cloaks

    Directory of Open Access Journals (Sweden)

    Veturia CHIROIU

    2016-12-01

    Full Text Available The principles by which the acoustics can be mimicked in order to reduce or cancel the vibrational field are based on anti-sound concept which can be materialized by acoustic cloaks. Geometric transformations open an elegant way towards the unconstrained control of sound through acoustic metamaterials. Acoustic cloaks can be achieved through geometric transformations which bring exotic metamaterial properties into the acoustic equations. Our paper brings new ideas concerning the technological keys for manufacturing of novel metamaterials based on the spatial compression of Cantor structures, and the architecture of 3D acoustic cloaks in a given frequency band, with application to architectural acoustics.

  20. Novel experimental surgical strategy to prevent traumatic neuroma formation by combining a 3D-printed Y-tube with an autograft.

    Science.gov (United States)

    Bolleboom, Anne; de Ruiter, Godard C W; Coert, J Henk; Tuk, Bastiaan; Holstege, Jan C; van Neck, Johan W

    2018-02-09

    OBJECTIVE Traumatic neuromas may develop after nerve injury at the proximal nerve stump, which can lead to neuropathic pain. These neuromas are often resistant to therapy, and excision of the neuroma frequently leads to recurrence. In this study, the authors present a novel surgical strategy to prevent neuroma formation based on the principle of centro-central anastomosis (CCA), but rather than directly connecting the nerve ends to an autograft, they created a loop using a 3D-printed polyethylene Y-shaped conduit with an autograft in the distal outlets. METHODS The 3D-printed Y-tube with autograft was investigated in a model of rat sciatic nerve transection in which the Y-tube was placed on the proximal sciatic nerve stump and a peroneal graft was placed between the distal outlets of the Y-tube to form a closed loop. This model was compared with a CCA model, in which a loop was created between the proximal tibial and peroneal nerves with a peroneal autograft. Additional control groups consisted of the closed Y-tube and the extended-arm Y-tube. Results were analyzed at 12 weeks of survival using nerve morphometry for the occurrence of neuroma formation and axonal regeneration in plastic semi-thin sections. RESULTS Among the different surgical groups, the Y-tube with interposed autograft was the only model that did not result in neuroma formation at 12 weeks of survival. In addition, a 13% reduction in the number of myelinated axons regenerating through the interposed autograft was observed in the Y-tube with autograft model. In the CCA model, the authors also observed a decrease of 17% in the number of myelinated axons, but neuroma formation was present in this model. The closed Y-tube resulted in minimal nerve regeneration inside the tube together with extensive neuroma formation before the entrance of the tube. The extended-arm Y-tube model clearly showed that the majority of the regenerating axons merged into the Y-tube arm, which was connected to the autograft

  1. Novel model for end-neuroma formation in the amputated rabbit forelimb

    Directory of Open Access Journals (Sweden)

    Kuiken Todd A

    2010-03-01

    Full Text Available Abstract Background The forelimb amputee poses many reconstructive challenges in the clinical setting, and there is a paucity of established surgical models for study. To further elucidate the pathogenic process in amputation neuroma formation, we created a reproducible, well-tolerated rabbit forelimb amputation model. Methods Upon approval from the Institutional Animal Care and Use Committee, 5 New Zealand White rabbits underwent left forelimb amputation. During this initial surgery, the median, radial and ulnar nerves were transected 1.6-2.5 (mean 2.0 cm distal to the brachial plexus, transposed onto the anterior chest wall and preserved at length. Six weeks subsequent to the amputation, the distal 5 mm of each neuroma was excised, and the remaining stump underwent histomorphometric analysis. Results The nerve cross sectional areas increased by factors of 1.99, 3.17, and 2.59 in the median (p = 0.077, radial (p Conclusion Given that the surgical model appears well-tolerated by the rabbits and that patterns of morphologic change are consistent and reproducible, we are encouraged to further investigate the utility of this model in the pathogenesis of neuroma formation.

  2. Three Cycles of Radiofrequency Ablation Are More Efficacious Than Two in the Management of Morton's Neuroma.

    Science.gov (United States)

    Brooks, David; Parr, Adam; Bryceson, William

    2018-04-01

    Morton's neuroma is a common cause of forefoot pain. Outcomes of conservative therapy are mixed and many patients undergo operative intervention. Radiofrequency ablation has recently gained favor as a treatment option, although the optimal regime is unknown. This study investigates the effectiveness of 2 versus 3 cycles of radiofrequency ablation for the treatment of Morton's neuroma. We surveyed a cohort of patients with Morton's neuroma who had progressed to radiofrequency ablation after failed conservative treatment. Patients received either 2 or 3 cycles of radiofrequency ablation by a single surgeon. We assessed patients based on their change in numerical pain rating scale, symptom improvement, complications, and progression to surgical excision through a series of telephone interviews. Outcomes between the 2 treatment arms were compared by parametric tests. Twenty-eight patients were included in the study. Eighteen patients with 21 neuromas received 2 cycles and 10 patients with 11 neuromas received 3 cycles. Mean time of follow-up was 12.9 months. Overall, 88% of patients were either very or moderately satisfied with their outcome. In patients who received 2 cycles mean numerical pain scores decreased from 7.9 ± 1.1 to 3.4 ± 2.4 postprocedure. Three patients progressed to operative excision. In patients who received 3 cycles, numerical pain scores decreased from 8.0 ± 1.0 to 1.5 ± 2.0 postprocedure. One patient progressed to operative excision. Patients who received 3 cycles had reduced medium-term pain postoperatively compared with 2 cycles (3.4 ± 2.4 vs 1.5 ± 2.0, P = .011). Radiofrequency ablation provides a high rate of patient satisfaction in the treatment of Morton's neuroma with few side effects. It appears that 3 cycles may be superior to 2 cycles but a randomized controlled trial will be required to confirm these results. Intervention, Level III: Comparative study without concurrent controls.

  3. T1-nerve root neuroma presenting with apical mass and Horner's syndrome

    Directory of Open Access Journals (Sweden)

    Podnar Simon

    2007-03-01

    Full Text Available Abstract Background The appearance of dumbbell neuroma of the first thoracic root is extremely rare. The extradural component of a T1-dumbbell neuroma may present as an apical mass. The diagnosis of hand weakness is complex and may be delayed in T1-neuroma because of absence of the palpable cervical mass. One-stage removal of a T1-root neuroma and its intrathoracic extension demanded an extended posterior midline approach in the sitting position. Case presentation A 51-year old man had suffered a traumatic partial tendon rupture of his wrist flexor muscles 6 years ago. Since the incident he occasionally felt fullness and tenderness in the affected forearm with some tingling in his fingers bilaterally. During the last two years the hand weakness was continuous and hypotrophy of the medial flexor and intrinsic hand muscles had become apparent. Electrophysiological studies revealed an ulnar neuropathy in addition to mild median and radial nerve dysfunction, including a mild contralateral carpal tunnel syndrome. The diagnostic work-up for multiple mononeuropathy in the upper extremity was negative. Repeated electrophysiological studies revealed fibrillations in the C7 paravertebral muscles on the affected side. Chest x-ray revealed a large round apical mass on the affected side. A Horner's syndrome was noted at this point of diagnostic work-up. MRI of the cervical and thoracic spine revealed a dumbbell T1 neuroma enlarging the intervertebral foramen at T1-2 and a 5 cm large extradural tumor with extension into the apex of the ipsilateral lung. The patient underwent surgery in sitting position using a left dorsal midline approach. Although the T1 root could not be preserved, the patient's neurological condition was unchanged after the surgery. Conclusion Extended posterior midline exposure described here using hemilaminectomy, unilateral facetectomy and costo-transversectomy is efficient and safe for one-stage removal of dumbbell tumors at the T1

  4. Traumatic neuroma after torticollis surgery: a rare occurrence

    African Journals Online (AJOL)

    2 Serrano Falcón C, Serrano Falcn MDM, Ruiz Villaverde R, Linares Solano J,. Serrano Ortega S. Amputation neuromas after neck surgery. Dermatol Online. J 2005; 11:2. 3 Lee IJ, Lim SY, Song HS, Park MC. Complete tight fibrous band release and resection in congenital muscular torticollis. J Plast Reconstr Aes Surg ...

  5. Validation of self-reported start year of mobile phone use in a Swedish case-control study on radiofrequency fields and acoustic neuroma risk.

    Science.gov (United States)

    Pettersson, David; Bottai, Matteo; Mathiesen, Tiit; Prochazka, Michaela; Feychting, Maria

    2015-01-01

    The possible effect of radiofrequency exposure from mobile phones on tumor risk has been studied since the late 1990s. Yet, empirical information about recall of the start of mobile phone use among adult cases and controls has never been reported. Limited knowledge about recall errors hampers interpretations of the epidemiological evidence. We used network operator data to validate the self-reported start year of mobile phone use in a case-control study of mobile phone use and acoustic neuroma risk. The answers of 96 (29%) cases and 111 (22%) controls could be included in the validation. The larger proportion of cases reflects a more complete and detailed reporting of subscription history. Misclassification was substantial, with large random errors, small systematic errors, and no significant differences between cases and controls. The average difference between self-reported and operator start year was -0.62 (95% confidence interval: -1.42, 0.17) years for cases and -0.71 (-1.50, 0.07) years for controls, standard deviations were 3.92 and 4.17 years, respectively. Agreement between self-reported and operator-recorded data categorized into short, intermediate and long-term use was moderate (kappa statistic: 0.42). Should an association exist, dilution of risk estimates and distortion of exposure-response patterns for time since first mobile phone use could result from the large random errors in self-reported start year. Retrospective collection of operator data likely leads to a selection of "good reporters", with a higher proportion of cases. Thus, differential recall cannot be entirely excluded.

  6. Neuroma prevention by end-to-side neurorraphy: an experimental study in rats.

    Science.gov (United States)

    Aszmann, Oskar C; Korak, Klaus J; Rab, Matthias; Grünbeck, Matthias; Lassmann, Hans; Frey, Manfred

    2003-11-01

    The successful treatment of painful neuromas remains a difficult goal to attain. In this report we explore the feasibility of neuroma prevention by insertion of the proximal end of a nerve through an end-to-side neurorraphy into an adjacent mixed nerve to provide a pathway and target for axons deprived of their end organ. Experiments were performed on a total of twenty 250-g Sprague-Dawley rats. Two groups of 10 animals were prepared. Group A served as an anatomic control. In group B the right saphenous nerve was transected and implanted end-to-side through an epineurial window into the tibial nerve distal to the trifurcation of the sciatic nerve. After 12 weeks the corresponding sensory neurons were identified by retrograde labeling techniques and histomorphometric analysis of the proximal and distal tibial nerve segments, and regular histology of the end-to-side site were performed. The results of the retrograde labeling of the corresponding sensory neuron pool of the saphenus nerve showed extensive labelling of the L1 to L3 spinal ganglions after intracutaneous tracer application of the planta pedis. The morphology of the end-to-side coaptation site and histomorphologic analysis prove that sensory neurons penetrate the perineurial sheath and axons regenerate along the tibial Schwann cell tubes toward their targets. Axons of a severed peripheral nerve that are provided with a pathway and target through an end-to-side coaptation will either be pruned or establish some type of end-organ contact so that a neuroma can be prevented. Whether these axons will lead to disturbing sensations such as paresthesia or dysesthesia in the newly found environment or remain silent codwellers, this experiment cannot answer. Long-term results of future clinical work will have to decide whether the prevention of the neuroma through end-to-side coaptation will be an appropriate therapy for this difficult problem.

  7. Acoustic Neuroma

    Science.gov (United States)

    ... below: ? Brain Tumors Brain Disorders AVMs Radiosurgery Gamma Knife Linac Radiotherapy Overview Childhood Brain Tumors Radiation Therapy Radiation Injury Treatment Day Making a Decision Centers of Excellence BRAIN TALK® ...

  8. Remission of severe restless legs syndrome and periodic limb movements in sleep after bilateral excision of multiple foot neuromas: a case report

    Directory of Open Access Journals (Sweden)

    Lettau Ludwig A

    2010-09-01

    Full Text Available Abstract Introduction Restless legs syndrome is a sensorimotor neurological disorder characterized by an urge to move the legs in response to uncomfortable leg sensations. While asleep, 70 to 90 percent of patients with restless legs syndrome have periodic limb movements in sleep. Frequent periodic limb movements in sleep and related brain arousals as documented by polysomnography are associated with poorer quality of sleep and daytime fatigue. Restless legs syndrome in middle age is sometimes associated with neuropathic foot dysesthesias. The causes of restless legs syndrome and periodic limb movements in sleep are unknown, but the sensorimotor symptoms are hypothesized to originate in the central nervous system. We have previously determined that bilateral forefoot digital nerve impingement masses (neuromas may be a cause of both neuropathic foot dysesthesias and the leg restlessness of restless legs syndrome. To the best of our knowledge, this case is the first report of bilateral foot neuromas as a cause of periodic limb movements in sleep. Case presentation A 42-year-old Caucasian woman with severe restless legs syndrome and periodic limb movements in sleep and bilateral neuropathic foot dysesthesias was diagnosed as having neuromas in the second, third, and fourth metatarsal head interspaces of both feet. The third interspace neuromas represented regrowth (or 'stump' neuromas that had developed since bilateral third interspace neuroma excision five years earlier. Because intensive conservative treatments including repeated neuroma injections and various restless legs syndrome medications had failed, radical surgery was recommended. All six neuromas were excised. Leg restlessness, foot dysesthesias and subjective sleep quality improved immediately. Assessment after 18 days showed an 84 to 100 percent reduction of visual analog scale scores for specific dysesthesias and marked reductions of pre-operative scores of the Pittsburgh sleep

  9. The accuracy of ultrasonography and magnetic resonance imaging for the diagnosis of Morton's neuroma: a systematic review

    International Nuclear Information System (INIS)

    Xu, Z.; Duan, X.; Yu, X.; Wang, H.; Dong, X.; Xiang, Z.

    2015-01-01

    Aim: To determine the accuracy of MRI versus ultrasound for Morton's neuroma. Materials and methods: A search was undertaken for clinical studies published in any language in PubMed up to the date of December 2013. Studies assessing the accuracy of the ultrasound or MRI for the diagnosis of Morton's neuroma were included. Data were pooled for meta-analysis. Study selection, data collection, and extraction were performed independently by two authors. Meta-disc 1.4 and Revman 5.2 software were applied for statistical analysis. Results: The study included 12 studies; 217 patients underwent MRI and 241 underwent ultrasound examinations. There appeared greater diagnostic accuracy for ultrasound than MRI for the diagnosis of Morton's neuroma (ultrasound sensitivity 90%, specificity 88%, positive likelihood ratio 2.77, negative likelihood ratio 0.16 versus MRI sensitivity 93%, specificity 68%, positive likelihood ratio 1.89, negative likelihood ratio 0.19). Conclusions: The available evidence suggests that ultrasound can provide better accuracy for the diagnosis of Morton's neuroma than MRI

  10. Traumatic Neuroma in a Breast Cancer Patient After Modified Radical Mastectomy: A Case Report

    International Nuclear Information System (INIS)

    Kim, Eun Young; Kang, Doo Kyoung; Kim, Tae Hee; Kim, Ku Sang; Yim, Hyunee

    2011-01-01

    Traumatic neuromas are rare benign lesions that develop from non-neoplastic proliferation of axons, schwann cells, and fibroblasts at the proximal end of transected or injured nerves as a result of trauma or surgery. We present the case of a traumatic neuroma in a 47-year-old female who was treated with a right modified radical mastectomy for breast cancer 14 years ago. Ultrasound examination revealed an oval-shaped hypoechoic nodule at the 9-O'clock position in the right chest wall. Color Doppler imaging showed no increased blood flow and a positron emission tomography-computed tomography examination revealed no fluorodeoxyglucose uptake in this nodule. The typical histologic findings were present.

  11. A computerized system based on an alternative pulse echo immersion technique for acoustic characterization of non-porous solid tissue mimicking materials

    Science.gov (United States)

    Nazihah Mat Daud, Anis; Jaafar, Rosly; Kadri Ayop, Shahrul; Supar Rohani, Md

    2018-04-01

    This paper discusses the development of a computerized acoustic characterization system of non-porous solid tissue mimicking materials. This system employs an alternative pulse echo immersion technique and consists of a pulser/receiver generator, a transducer used as both a transmitter and a receiver, a digital oscilloscope, and a personal computer with a custom-developed program installed. The program was developed on the LabVIEW 2012 platform and comprises two main components, a user interface and a block diagram. The user interface consists of three panels: a signal acquisition and selection panel, a display panel, and a calculation panel. The block diagram comprises four blocks: a signal acquisition block, a peak signal analysis block, an acoustic properties calculation and display block, and an additional block. Interestingly, the system can be operated in both online and offline modes. For the online mode, the measurements are performed by connecting the system with a Rigol DS2000 Series digital oscilloscope. In contrast, the measurements are carried out by processing the saved data on the computer for the offline mode. The accuracy and consistency of the developed system was validated by a KB-Aerotech Alpha Series transducer with 5 MHz center frequency and a Rigol DS2202 two-channel 200 MHz 2 GSa s-1 digital oscilloscope, based on the measurement of the acoustic properties of three poly(methyl methacrylate) samples immersed in a medium at a temperature of (24.0  ±  0.1) °C. The findings indicated that the accuracy and consistency of the developed system was exceptionally high, within a 1.04% margin of error compared to the reference values. As such, this computerized system can be efficiently used for the acoustic characterization of non-porous solid tissues, given its spontaneous display of results, user-friendly interface, and convenient hardware connection.

  12. Ultrasound versus magnetic resonance imaging for Morton neuroma: systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bignotti, Bianca; Martinoli, Carlo [University of Genoa, Radiology Department, Genoa, Genova (Italy); Signori, Alessio; Sormani, Maria Pia [University of Genoa, Institute of Statistics, Department of Health Sciences, Genoa (Italy); Molfetta, Luigi [University of Genoa, Department of Neurosciences, Rehabilitation, Ophthalmology, Genetics (DINOGMI), Genoa (Italy); Tagliafico, Alberto [University of Genoa, Institute of Anatomy, Department of Experimental Medicine, Genoa (Italy)

    2015-08-15

    To compare ultrasound (US) and magnetic resonance imaging (MRI) in the diagnosis of Morton's neuroma. Studies that assessed the diagnostic accuracy of US and MRI for Morton's neuroma were retrieved from major medical libraries independently by two reviewers up to 1 April 2014. Predefined inclusion and exclusion criteria were adopted. 277 studies were initially found, and the meta-analysis was conducted on 14 studies. US sensitivity was studied in five studies, MRI sensitivity in three studies, and both in six studies. All studies used surgery as the reference standard. A high sensitivity (SE) of diagnostic testing was observed for both US (SE (95 % CI) = 0.91 (0.83-0.96)) and MRI (SE (95 % CI) = 0.90 (0.82-0.96)) with no significant differences between the two modalities in diagnosis (Q test p = 0.88). For MRI, specificity of test was 1.00 with a pooled estimation of 1.00 (0.73-1.00), while the pooled specificity was 0.854 (95 % CI: 0.41-1.00) for US. No differences were observed between US and MRI in study design (p = 0.76). This meta-analysis shows that the SE of US (0.91) is equal to (p = 0.88) that of MRI (0.90) for identification of Morton's neuroma. (orig.)

  13. Traumatic Neuroma in a Breast Cancer Patient After Modified Radical Mastectomy: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young; Kang, Doo Kyoung; Kim, Tae Hee [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Kim, Ku Sang [Dept. of Surgery, Ajou University School of Medicine, Suwon (Korea, Republic of); Yim, Hyunee [Dept. of Pathology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2011-05-15

    Traumatic neuromas are rare benign lesions that develop from non-neoplastic proliferation of axons, schwann cells, and fibroblasts at the proximal end of transected or injured nerves as a result of trauma or surgery. We present the case of a traumatic neuroma in a 47-year-old female who was treated with a right modified radical mastectomy for breast cancer 14 years ago. Ultrasound examination revealed an oval-shaped hypoechoic nodule at the 9-O'clock position in the right chest wall. Color Doppler imaging showed no increased blood flow and a positron emission tomography-computed tomography examination revealed no fluorodeoxyglucose uptake in this nodule. The typical histologic findings were present.

  14. Full experimental modelling of a liver tissue mimicking phantom for medical ultrasound studies employing different hydrogels.

    Science.gov (United States)

    Casciaro, Sergio; Conversano, Francesco; Musio, Stefano; Casciaro, Ernesto; Demitri, Christian; Sannino, Alessandro

    2009-04-01

    Tissue mimicking phantoms have been widely reported to be an important tool for development, optimisation and performance testing of ultrasound-based diagnostic techniques. In particular, modern applications of tissue mimicking phantoms often include characterisation of the nonlinear behaviour of experimental ultrasound contrast agents. In such cases, the tissue-mimicking materials should be chosen not only based on the values of their density, speed of sound and attenuation coefficient, but also considering their effect on the appearance of "native harmonics" due to nonlinear distortion of ultrasound signal during propagation. In a previous paper it was demonstrated that a cellulose-based hydrogel is suitable to simulate nonlinear acoustical behaviour of liver tissue for thicknesses up to 8 cm. In this paper we present the experimental characterisation of the nonlinear acoustical behaviour of a different polyethylene glycol diacrylate (PEGDA)-based hydrogel, in order to assess whether and how it can improve the performances and overcome some limitations of the cellulose-based hydrogel as liver tissue-mimicking material. Samples of pig liver tissue, cellulose-based hydrogel and PEGDA-based hydrogel were insonified in a through-transmission set-up, employing 2.25-MHz pulses with different mechanical index (MI) values. Second harmonic and first harmonic amplitudes were extracted from the spectra of received signals and their difference was then used to compare sample behaviours. Obtained results show how a new more accurate and combined experimental model of linear and nonlinear acoustical behaviour of liver tissue is feasible. In fact, a further confirmation of the cellulose-based hydrogel effectiveness to precisely simulate the liver tissue for penetration depths up to 8 cm was provided, and it was also shown that the employment of the PEGDA-based hydrogel can extend the range of useful tissue-mimicking material thicknesses up to 11 cm, moreover allowing a

  15. Reexcision Perineural Invasion and Epithelial Sheath Neuroma Possibly on a Spectrum of Postinjury Reactive Hyperplasia Mediated by IL-6.

    Science.gov (United States)

    Wang, James Y; Nuovo, Gerard; Kline, Mitchell; Magro, Cynthia M

    2017-01-01

    Epithelial sheath neuroma is a rarely recognized but established entity in the medical literature. First described in 2000 by Requena et al, there have only been 7 published cases to date, mostly in female patients and presenting as symptomatic solitary lesions on the back without a known history of trauma. In 2006, Beer et al described and reviewed a dozen cases in which epithelial sheath neuroma-like features were seen in the advent of a surgical procedure, which was termed "re-excision perineural invasion" and attributed to possible eccrine duct implantation during surgery. Our case is a 66-year-old male patient who underwent an excision of a melanocytic neoplasm in which a reactive epithelial sheath neuroma was incidentally discovered in the excision specimen, adjacent to the biopsy site cicatrix. Histologically, there was benign cutaneous nerve hyperplasia with a proliferation of squamous epithelium in intimate apposition to the nerve bundles in the superficial dermis. We postulate that the process active in the formation of re-excision perineural invasion is the same as in epithelial sheath neuroma and that minor trauma not appreciable on histologic examination is responsible in the latter entity. We performed IL-6 staining and documented that IL-6 was upregulated at the interface of the nerve and reactive epithelium, but was absent in nerves distant from the site of surgery, suggesting that IL-6 may be essential to the lesion's development. The recognition of reactive epithelial sheath neuroma including the subcategory of re-excision perineural invasion is crucial for the dermatopathologist to prevent mislabeling this reactive entity as a perineural squamous cell carcinoma, which has clinical consequences for the patient such as wider re-excision and radiation treatment. Additionally, we have identified a potential pathophysiologic basis for this lesion.

  16. Fibromatosis of the breast mimicking an abscess: case report of unusual sonographic features.

    Science.gov (United States)

    Lee, So Min; Lee, Ji Young; Lee, Byung Hoon; Kim, Su Young; Joo, Mee; Kim, Jae Il

    2015-01-01

    Fibromatosis of the breast, also known as a desmoid tumor, is extremely rare and most often appears as an aggressive lesion mimicking breast carcinoma. It lacks metastatic potential but can grow aggressively in a localized area. Ultrasonography often shows an irregular spiculated hypoechoic mass with posterior acoustic shadowing. We discuss a case of breast fibromatosis that presented as a painful palpable breast mass in a 32-year-old woman and mimicked an abscess in the sonogram. We found that this lesion displayed atypical sonographic features such as a heterogeneous echoic mass with an internal anechoic area. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. The use of multimedia as an adjunct to the informed consent process for Morton's neuroma resection surgery.

    Science.gov (United States)

    Wang, Calvin; Ammon, Peter; Beischer, Andrew D

    2014-10-01

    The purpose of this study was to assess if a computer-based multimedia education module (MEM) improved patients' comprehension when used as an adjunct to the standard verbal consent process for Morton's neuroma resection surgery. Nineteen patients (15 females and 4 males) considered candidates for Morton's neuroma resection surgery were prospectively recruited. A standardized verbal discussion was had with each patient regarding risks and benefits of surgery, alternative treatments, and the usual postoperative course. Patient understanding was then assessed with a questionnaire. Each patient subsequently viewed the MEM and the questionnaire was repeated. Patients also rated ease of understanding and satisfaction with both methods of patient education. Patients answered a significantly greater proportion of correct answers after viewing the MEM module (85%), compared to verbal discussion alone (61%) (P = .002). Patients rated both the ease of understanding of the module and amount of information provided by the module as a mean of 9.3 cm on a 10 cm Visual Analog Scale (VAS). The majority of patients (76%) rated the multimedia tool as having answered their questions about surgery as well or better than the treating surgeon. An interactive multimedia educational tool was a useful adjunct to the informed consent process for patients considering Morton's neuroma resection surgery. Level II, prospective cohort study. © The Author(s) 2014.

  18. Treatment of Acoustic Neuroma

    Science.gov (United States)

    ... Home Learn Treatment Options Overview English English Arabic Catalan Chinese (Simplified) Chinese (Traditional) Danish French German Greek ... for delivering stereotactic radiation have improved, an increasing number of patients have chosen to receive stereotactic radiosurgery ...

  19. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Meeting Host a Meeting Volunteer Become a Volunteer Opportunities Support Overview Patient Events Fundraising Programs Join Team ... Host a meeting Volunteer Back Volunteering with ANA Opportunities Fundraising Programs Back Join Team ANA Legacy Society ...

  20. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Support Groups Is a support group for me? Find a Group Upcoming Events Video Library Photo Gallery ... Support ANetwork Peer Support Program Community Connections Overview Find a Meeting Host a Meeting Volunteer Become a ...

  1. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Library Photo Gallery One-on-One Support ANetwork Peer Support Program Community Connections Overview Find a Meeting ... Photo Gallery One-on-One Support Back ANetwork Peer Support Program Community Connections Back Overview Find a ...

  2. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Johns Hopkins Patient Event - Vanderbilt Resources Back Patient Resources Request a Patient Kit Healthcare Choosing a Healthcare Provider Related Links Healthcare Provider List Member Portal Webinar ...

  3. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... for me? Find a Group Upcoming Events Video Library Photo Gallery One-on-One Support ANetwork Peer ... me? Find a group Back Upcoming events Video Library Photo Gallery One-on-One Support Back ANetwork ...

  4. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... 8211 info@ANAUSA.org About ANA Mission, Vision & Values Leadership & Staff Annual Reports Shop ANA Home Learn Educational Video English English Arabic Catalan Chinese (Simplified) Chinese ( ...

  5. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Research Back Keck Medicine of USC Massachusetts General Hospital University of California, Irvine A.N.S.R.S. Study Yale University Vanderbilt University Mayo Clinic Patient Registry Caregivers Public Webinars Patient Stories Keywords ...

  6. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... info@ANAUSA.org About ANA Mission, Vision & Values Leadership & Staff Annual Reports Shop ANA Home Learn Educational Video English English Arabic Catalan Chinese (Simplified) Chinese ( ...

  7. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Hospital University of California, Irvine A.N.S.R.S. Study Yale University Vanderbilt University Mayo Clinic Patient Registry Caregivers Public Webinars Patient Stories Keywords Shop ANA Discussion Forum ...

  8. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Legacy Society Ways to Give Help us fundraise Caregiver Overview Resources Support Groups Back Is a support ... Legacy Society Ways to give Help us fundraise Caregiver Back Overview Resources Support Overview Event Calendar Patient ...

  9. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Opportunities Support Overview Patient Events Fundraising Programs Join Team ANA Legacy Society Ways to Give Help us ... Volunteering with ANA Opportunities Fundraising Programs Back Join Team ANA Legacy Society Ways to give Help us ...

  10. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Opportunities Support Overview Patient Events Fundraising Programs Join Team ANA Legacy Society Ways to Give Help us fundraise Caregiver Overview Resources Support Groups Back Is a support group for me? Find ...

  11. Acoustic Neuroma Educational Video

    Medline Plus

    Full Text Available ... Provider List Member Portal Back Webinar Library Newsletter Library Patient Info Booklets Research Back ANA Survey/Registry AN Research Back Keck Medicine of USC Massachusetts General Hospital University of California, Irvine A.N.S.R.S. Study Yale ...

  12. Effect of Graphite Concentration on Shear-Wave Speed in Gelatin-Based Tissue-Mimicking Phantoms

    Science.gov (United States)

    Anderson, Pamela G.; Rouze, Ned C.; Palmeri, Mark L.

    2011-01-01

    Elasticity-based imaging modalities are becoming popular diagnostic tools in clinical practice. Gelatin-based, tissue mimicking phantoms that contain graphite as the acoustic scattering material are commonly used in testing and validating elasticity-imaging methods to quantify tissue stiffness. The gelatin bloom strength and concentration are used to control phantom stiffness. While it is known that graphite concentration can be modulated to control acoustic attenuation, the impact of graphite concentrationon phantom elasticity has not been characterized in these gelatin phantoms. This work investigates the impact of graphite concentration on phantom shear stiffness as characterized by shear-wave speed measurements using impulsive acoustic-radiation-force excitations. Phantom shear-wave speed increased by 0.83 (m/s)/(dB/(cm MHz)) when increasing the attenuation coefficient slope of the phantom material through increasing graphite concentration. Therefore, gelatin-phantom stiffness can be affected by the conventional ways that attenuation is modulated through graphite concentration in these phantoms. PMID:21710828

  13. Hydrogel based tissue mimicking phantom for in-vitro ultrasound contrast agents studies.

    Science.gov (United States)

    Demitri, Christian; Sannino, Alessandro; Conversano, Francesco; Casciaro, Sergio; Distante, Alessandro; Maffezzoli, Alfonso

    2008-11-01

    Ultrasound medical imaging (UMI) is the most widely used image analysis technique, and often requires advanced in-vitro set up to perform morphological and functional investigations. These studies are based on contrast properties both related to tissue structure and injectable contrast agents (CA). In this work, we present a three-dimensional structure composed of two different hydrogels reassembly the microvascular network of a human tissue. This phantom was particularly suitable for the echocontrastographic measurements in human microvascular system. This phantom has been characterized to present the acoustic properties of an animal liver, that is, acoustic impedance (Z) and attenuation coefficient (AC), in UMI signal analysis in particular; the two different hydrogels have been selected to simulate the target organ and the acoustic properties of the vascular system. The two hydrogels were prepared starting from cellulose derivatives to simulating the target organ parenchyma and using a PEG-diacrylate to reproduce the vascular system. Moreover, harmonic analysis was performed on the hydrogel mimicking the liver parenchyma hydrogel to evaluate the ultrasound (US) distortion during echographic measurement. The phantom was employed in the characterization of an experimental US CA. Perfect agreement was found when comparing the hydrogel acoustical properties materials with the corresponding living reference tissues (i.e., vascular and parenchimal tissue).

  14. Manual therapy in the management of a patient with a symptomatic Morton's Neuroma: A case report.

    Science.gov (United States)

    Sault, Josiah D; Morris, Matthew V; Jayaseelan, Dhinu J; Emerson-Kavchak, Alicia J

    2016-02-01

    Patients with Morton's neuroma are rarely referred to physical therapy. This case reports the resolution of pain, increase in local pressure pain thresholds, and improvement of scores on the Lower Extremity Functional Scale and Foot and Ankle Ability Measure following a course of joint based manual therapy for a patient who had failed standard conservative medical treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  16. Roentgenographic features of neurofibromatosis von Recklinghausen

    Energy Technology Data Exchange (ETDEWEB)

    Galanski, M.; Vogelsang, H.; Cramer, B.M.; Thun, F.; Peters, P.E.

    1983-10-01

    The basic abnormality of neurofibromatosis consists not only of a maldevelopment of the neuroectoderm but also of the mesoderm. Therefore any organ or system of the body may be involved. Following a short clinical review of the central (acoustic) and peripheral type the well known and the more unusual radiographic findings are summarized. They include cranial and intracranial manifestations (orbitosphenoid dysplasia, bone defects of the skull, acoustic neuroma, glioma of the optic nerve and chiasm, meningioma), spinal lesions (scoliosis, vetebral scalloping, meningocele, neuroma, ependymoma), skeletal abnormalities (pseudarthrosis), cardiovascular manifestations, pulmonary fibrosis, tumors of the gastrointestinal and urinary tract and different endocrinopathies. Some of the roentgeologic symptoms are very characteristic and allow definitive diagnosis.

  17. A review of suspension-Scattered particles used in blood-mimicking fluid for doppler ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Ammar A Oglat

    2018-01-01

    Full Text Available Doppler ultrasound imaging system description and calibration need blood-mimicking fluids (BMFs for the test target of medical ultrasound diagnostic tools, with known interior features and acoustic and physical properties of this fluid (BMF. Physical and acoustical properties determined in the International Electrotechnical Commission (IEC standard are specified as constant values, the materials used in the BMF preparation should have values similar to the IEC standard values. However, BMF is ready-made commercially from a field of medical usage, which may not be appropriate in the layout of ultrasound system or for an estimate of novel imaging mechanism. It is often eligible to have the capability to make sound properties and mimic blood arrangement for specific applications. In this review, sufficient BMF materials, liquids, and measures are described which have been generated by utilizing diverse operation mechanism and materials that have sculptured a range of biological systems.

  18. How Loud Is Too Loud?

    Science.gov (United States)

    ... Ménière's Disease Noise-Induced Hearing Loss Otosclerosis Pendred Syndrome Retinitis Pigmentosa - National Eye Institute Sudden Deafness Tinnitus Usher Syndrome Vestibular Schwannoma (Acoustic Neuroma) and Neurofibromatosis Who ...

  19. Hearing loss as an unusual consequence of metastatic gastric adenocarcinoma

    Directory of Open Access Journals (Sweden)

    CE Owers

    2010-10-01

    Full Text Available A sixty-one year old man was referred with a history of progressive dysphagia, vomiting and weight loss with some back pain. Upper gastrointestinal endoscopy and biopsies revealed a gastro-oesophageal junction adenocarcinoma. Despite the absence of metastatic disease on computed tomography, positron emission tomography demonstrated multiple vertebral and sternal deposits. He was reviewed in an ENT clinic with a sudden onset of hearing loss accompanied by dizziness, but no focal neurology. Magnetic resonance imaging identified bilateral 2cm lesions at the internal auditory meatus, consistent with a diagnosis of bilateral acoustic neuromas. The patient subsequently died of carcinomatosis and, because of the potential familial significance of bilateral acoustic neuromas, a limited post-mortem examination was carried out. Unexpectedly, this revealed bilateral adenocarcinoma metastases infiltrating the internal auditory meatus affecting the acoustic nerves. The authors believe this a very rare presentation of metastatic gastric disease.

  20. Brain tumor - primary - adults

    Science.gov (United States)

    ... Vestibular schwannoma (acoustic neuroma) - adults; Meningioma - adults; Cancer - brain tumor (adults) ... Primary brain tumors include any tumor that starts in the brain. Primary brain tumors can start from brain cells, ...

  1. Direct costs of microsurgical management of radiosurgically amenable intracranial pathology in Germany: an analysis of meningiomas, acoustic neuromas, metastases and arteriovenous malformations of less than 3 cm in diameter

    International Nuclear Information System (INIS)

    Wellis, G.; Nagel, R.; Vollmar, C.; Steiger, H.-J.

    2003-01-01

    The purpose of the analysis was to appreciate and compare the effective direct costs of microsurgical treatment of intracranial pathology potentially amenable to radiosurgery as they arose in 1998-99. Treatment costs of 127 microsurgically treated patients harboring an arteriovenous malformation (AVM), acoustic neuroma, meningioma or brain metastasis potentially amenable to radiosurgery were reviewed. Costs for the surgical procedure, ICU rare, medical and nursing care on the ward, interclinical bills (ICB) for services provided by other departments and the overhead for basic hotel service were added. For comparison gamma knife costs were calculated by dividing the global operating cost of the gamma knife centre by the number of patients treated in 1999. Average hospitalization time for the entire microsurgical patients was 15.4 + 8.6 days. The patients spent an average of 1.2 ± 2.8 days on ICU. Average operating time for all patients, including preparation, was 393 ± 118 minutes. Average costs for the microsurgical therapy were Eur 10814 ± 6108. These consisted of Eur 1417 ± 426 for the surgical procedure, Eur 1188 ± 2658 for ICU care, Eur 2333 ± 1582 for medical and nursing care on the ward, Eur 1671 ± 1433 for interclinical bills and Eur 4204 ± 2338 for basic hotel service (overhead, Eur 273 per day). 70 % of the microsurgically treated patients needed ancillary inpatient rehabilitation or radiotherapy resulting in an average additional cost for all patients of Eur 2744. Furthermore 20 % of the microsurgically treated patients required an unplanned readmission after discharge, resulting in an average additional costs for all patients of Eur 1684. Average overall costs per patient including ancillary therapy and unplanned read-missions amounted to Eur 15242. For comparison, gamma knife treatment costs per patient amounted to Eur 7920 in 1999. The current analysis showed that for established radiosurgical indications the primary costs of microsurgery

  2. Acoustic window planning for ultrasound acquisition.

    Science.gov (United States)

    Göbl, Rüdiger; Virga, Salvatore; Rackerseder, Julia; Frisch, Benjamin; Navab, Nassir; Hennersperger, Christoph

    2017-06-01

    Autonomous robotic ultrasound has recently gained considerable interest, especially for collaborative applications. Existing methods for acquisition trajectory planning are solely based on geometrical considerations, such as the pose of the transducer with respect to the patient surface. This work aims at establishing acoustic window planning to enable autonomous ultrasound acquisitions of anatomies with restricted acoustic windows, such as the liver or the heart. We propose a fully automatic approach for the planning of acquisition trajectories, which only requires information about the target region as well as existing tomographic imaging data, such as X-ray computed tomography. The framework integrates both geometrical and physics-based constraints to estimate the best ultrasound acquisition trajectories with respect to the available acoustic windows. We evaluate the developed method using virtual planning scenarios based on real patient data as well as for real robotic ultrasound acquisitions on a tissue-mimicking phantom. The proposed method yields superior image quality in comparison with a naive planning approach, while maintaining the necessary coverage of the target. We demonstrate that by taking image formation properties into account acquisition planning methods can outperform naive plannings. Furthermore, we show the need for such planning techniques, since naive approaches are not sufficient as they do not take the expected image quality into account.

  3. How Loud Is Too Loud?

    Medline Plus

    Full Text Available ... Ménière's Disease Noise-Induced Hearing Loss Otosclerosis Pendred Syndrome Retinitis Pigmentosa - National Eye Institute Sudden Deafness Tinnitus Usher Syndrome Vestibular Schwannoma (Acoustic Neuroma) and Neurofibromatosis Who ...

  4. Automated gamma knife radiosurgery treatment planning with image registration, data-mining, and Nelder-Mead simplex optimization

    International Nuclear Information System (INIS)

    Lee, Kuan J.; Barber, David C.; Walton, Lee

    2006-01-01

    Gamma knife treatments are usually planned manually, requiring much expertise and time. We describe a new, fully automatic method of treatment planning. The treatment volume to be planned is first compared with a database of past treatments to find volumes closely matching in size and shape. The treatment parameters of the closest matches are used as starting points for the new treatment plan. Further optimization is performed with the Nelder-Mead simplex method: the coordinates and weight of the isocenters are allowed to vary until a maximally conformal plan specific to the new treatment volume is found. The method was tested on a randomly selected set of 10 acoustic neuromas and 10 meningiomas. Typically, matching a new volume took under 30 seconds. The time for simplex optimization, on a 3 GHz Xeon processor, ranged from under a minute for small volumes ( 30 000 cubic mm,>20 isocenters). In 8/10 acoustic neuromas and 8/10 meningiomas, the automatic method found plans with conformation number equal or better than that of the manual plan. In 4/10 acoustic neuromas and 5/10 meningiomas, both overtreatment and undertreatment ratios were equal or better in automated plans. In conclusion, data-mining of past treatments can be used to derive starting parameters for treatment planning. These parameters can then be computer optimized to give good plans automatically

  5. Laser-generated ultrasound for high-precision cutting of tissue-mimicking gels (Conference Presentation)

    Science.gov (United States)

    Lee, Taehwa; Luo, Wei; Li, Qiaochu; Guo, L. Jay

    2017-03-01

    Laser-generated focused ultrasound has shown great promise in precisely treating cells and tissues by producing controlled micro-cavitation within the acoustic focal volume (30 MPa, negative pressure amplitude). By moving cavitation spots along pre-defined paths through a motorized stage, tissue-mimicking gels of different elastic moduli were cut into different shapes (rectangle, triangle, and circle), leaving behind the same shape of holes, whose sizes are less than 1 mm. The cut line width is estimated to be less than 50 um (corresponding to localized cavitation region), allowing for accurate cutting. This novel approach could open new possibility for in-vivo treatment of diseased tissues in a high-precision manner (i.e., high-precision invisible sonic scalpel).

  6. How Loud Is Too Loud?

    Medline Plus

    Full Text Available ... to the Brain Video Ménière's Disease Noise-Induced Hearing Loss Otosclerosis Pendred Syndrome Retinitis Pigmentosa - National Eye Institute Sudden Deafness Tinnitus Usher Syndrome Vestibular Schwannoma (Acoustic Neuroma) and Neurofibromatosis Who ...

  7. Bone tumor mimickers: A pictorial essay

    International Nuclear Information System (INIS)

    Mhuircheartaigh, Jennifer Ni; Lin, Yu-Ching; Wu, Jim S

    2014-01-01

    Focal lesions in bone are very common and many of these lesions are not bone tumors. These bone tumor mimickers can include numerous normal anatomic variants and non-neoplastic processes. Many of these tumor mimickers can be left alone, while others can be due to a significant disease process. It is important for the radiologist and clinician to be aware of these bone tumor mimickers and understand the characteristic features which allow discrimination between them and true neoplasms in order to avoid unnecessary additional workup. Knowing which lesions to leave alone or which ones require workup can prevent misdiagnosis and reduce patient anxiety

  8. How Loud Is Too Loud?

    Medline Plus

    Full Text Available ... Syndrome Vestibular Schwannoma (Acoustic Neuroma) and Neurofibromatosis Who Can I Turn to for Help with My Hearing ... Free Publications Glossary Have a question? Information specialists can answer your questions in English or Spanish. Voice: ( ...

  9. Moderately nonlinear ultrasound propagation in blood-mimicking fluid.

    Science.gov (United States)

    Kharin, Nikolay A; Vince, D Geoffrey

    2004-04-01

    In medical diagnostic ultrasound (US), higher than-in-water nonlinearity of body fluids and tissue usually does not produce strong nonlinearly distorted waves because of the high absorption. The relative influence of absorption and nonlinearity can be characterized by the Gol'dberg number Gamma. There are two limiting cases in nonlinear acoustics: weak waves (Gamma 1). However, at diagnostic frequencies in tissue and body fluids, the nonlinear effects and effects of absorption more likely are comparable (Gol'dberg number Gamma approximately 1). The aim of this work was to study the nonlinear propagation of a moderately nonlinear US second harmonic signal in a blood-mimicking fluid. Quasilinear solutions to the KZK equation are presented, assuming radiation from a flat and geometrically focused circular Gaussian source. The solutions are expressed in a new simplified closed form and are in very good agreement with those of previous studies measuring and modeling Gaussian beams. The solutions also show good agreement with the measurements of the beams produced by commercially available transducers, even without special Gaussian shading.

  10. Accumulation of Kv7.2 channels in putative ectopic transduction zones of mice nerve-end neuromas

    Directory of Open Access Journals (Sweden)

    Lopez-García Jose A

    2011-08-01

    Full Text Available Abstract Background Modulation of M-type currents has been proposed as a new strategy for the treatment of neuropathic pain due to their role in regulating neuronal excitability. Using electrophysiological techniques we showed previously that the opening of Kv7 channels with retigabine, blocked ectopic discharges from axotomized fibers but did not alter transduction at intact skin afferents. We hypothesized that after nerve damage, accumulation of Kv7 channels in afferent fibers may increase M-type currents which then acquired a more important role at regulating fiber excitability. Findings In this study, we used an immunohistochemical approach to examine patterns of expression of Kv7.2 channels in afferent fibers after axotomy and compared them to patterns of expression of voltage gated Na+ channels (Nav which are key electrogenic elements in peripheral axons known to accumulate in experimental and human neuromas. Axotomy induced an enlargement and narrowing of the nodes of Ranvier at the proximal end of the neuroma together with a dramatic demyelination and loss of structure at its distal end in which naked accumulations of Nav were present. In addition, axotomy also induced accumulations of Kv7.2 that co-localized with those of Nav channels. Conclusions Whilst Nav channels are mandatory for initiation of action potentials, (i.e. responsible for the generation/propagation of ectopic discharges an increased accumulation of Kv7.2 channels after axotomy may represent a homeostatic compensation to over excitability in axotomized fibers, opening a window for a peripheral action of M-current modulators under conditions of neuropathy.

  11. Impact of video-endoscopy on the results of retrosigmoid-transmeatal microsurgery of vestibular schwannoma: prospective study

    Czech Academy of Sciences Publication Activity Database

    Chovanec, M.; Zvěřina, E.; Profant, Oliver; Skřivan, J.; Čakrt, O.; Lisý, J.; Betka, J.

    2013-01-01

    Roč. 270, č. 4 (2013), s. 1277-1284 ISSN 0937-4477 Grant - others:GA MZd(CZ) NS9909 Institutional support: RVO:68378041 Keywords : vestibular schwannoma * acoustic neuroma * endoscopy-assisted microsurgery Subject RIV: FH - Neurology Impact factor: 1.608, year: 2013

  12. Convergent acoustic field of view in echolocating bats

    DEFF Research Database (Denmark)

    Jakobsen, Lasse; Ratcliffe, John M; Surlykke, Annemarie

    2013-01-01

    Most echolocating bats exhibit a strong correlation between body size and the frequency of maximum energy in their echolocation calls (peak frequency), with smaller species using signals of higher frequency than larger ones. Size-signal allometry or acoustic detection constraints imposed on wavel......Most echolocating bats exhibit a strong correlation between body size and the frequency of maximum energy in their echolocation calls (peak frequency), with smaller species using signals of higher frequency than larger ones. Size-signal allometry or acoustic detection constraints imposed...... on wavelength by preferred prey size have been used to explain this relationship. Here we propose the hypothesis that smaller bats emit higher frequencies to achieve directional sonar beams, and that variable beam width is critical for bats. Shorter wavelengths relative to the size of the emitter translate...... into more directional sound beams. Therefore, bats that emit their calls through their mouths should show a relationship between mouth size and wavelength, driving smaller bats to signals of higher frequency. We found that in a flight room mimicking a closed habitat, six aerial hawking vespertilionid...

  13. A theoretical and experimental investigation of nonlinear propagation of ultrasound through tissue mimicking media

    Science.gov (United States)

    Rielly, Matthew Robert

    An existing numerical model (known as the Bergen code) is used to investigate finite amplitude ultrasound propagation through multiple layers of tissue-like media. This model uses a finite difference method to solve the nonlinear parabolic KZK wave equation. The code is modified to include an arbitrary frequency dependence of absorption and transmission effects for wave propagation across a plane interface at normal incidence. In addition the code is adapted to calculate the total intensity loss associated with the absorption of the fundamental and nonlinearly generated harmonics. Measurements are also taken of the axial nonlinear pressure field generated from a circular focused, 2.25 MHz source, through single and multiple layered tissue mimicking fluids, for source pressures in the range from 13 kPa to 310 kPa. Two tissue mimicking fluids are developed to provide acoustic properties similar to amniotic fluid and a typical soft tissue. The values of the nonlinearity parameter, sound velocity and frequency dependence of attenuation for both fluids are presented, and the measurement procedures employed to obtain these characteristics are described in detail. These acoustic parameters, together with the measured source conditions are used as input to the numerical model, allowing the experimental conditions to be simulated. Extensive comparisons are made between the model's predictions and the axial pressure field measurements. Results are presented in the frequency domain showing the fundamental and three subsequent harmonic amplitudes on axis, as a function of axial distance. These show that significant nonlinear distortion can occur through media with characteristics typical of tissue. Time domain waveform comparisons are also made. An excellent agreement is found between theory and experiment indicating that the model can be used to predict nonlinear ultrasound propagation through multiple layers of tissue-like media. The numerical code is also used to model the

  14. Acoustic/seismic signal propagation and sensor performance modeling

    Science.gov (United States)

    Wilson, D. Keith; Marlin, David H.; Mackay, Sean

    2007-04-01

    Performance, optimal employment, and interpretation of data from acoustic and seismic sensors depend strongly and in complex ways on the environment in which they operate. Software tools for guiding non-expert users of acoustic and seismic sensors are therefore much needed. However, such tools require that many individual components be constructed and correctly connected together. These components include the source signature and directionality, representation of the atmospheric and terrain environment, calculation of the signal propagation, characterization of the sensor response, and mimicking of the data processing at the sensor. Selection of an appropriate signal propagation model is particularly important, as there are significant trade-offs between output fidelity and computation speed. Attenuation of signal energy, random fading, and (for array systems) variations in wavefront angle-of-arrival should all be considered. Characterization of the complex operational environment is often the weak link in sensor modeling: important issues for acoustic and seismic modeling activities include the temporal/spatial resolution of the atmospheric data, knowledge of the surface and subsurface terrain properties, and representation of ambient background noise and vibrations. Design of software tools that address these challenges is illustrated with two examples: a detailed target-to-sensor calculation application called the Sensor Performance Evaluator for Battlefield Environments (SPEBE) and a GIS-embedded approach called Battlefield Terrain Reasoning and Awareness (BTRA).

  15. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties.

    Science.gov (United States)

    Cournane, S; Cannon, L; Browne, J E; Fagan, A J

    2010-10-07

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 µm Al(2)O(3) and 3 µm Al(2)O(3), were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s(-1), respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  16. Spectral estimation for characterization of acoustic aberration.

    Science.gov (United States)

    Varslot, Trond; Angelsen, Bjørn; Waag, Robert C

    2004-07-01

    Spectral estimation based on acoustic backscatter from a motionless stochastic medium is described for characterization of aberration in ultrasonic imaging. The underlying assumptions for the estimation are: The correlation length of the medium is short compared to the length of the transmitted acoustic pulse, an isoplanatic region of sufficient size exists around the focal point, and the backscatter can be modeled as an ergodic stochastic process. The motivation for this work is ultrasonic imaging with aberration correction. Measurements were performed using a two-dimensional array system with 80 x 80 transducer elements and an element pitch of 0.6 mm. The f number for the measurements was 1.2 and the center frequency was 3.0 MHz with a 53% bandwidth. Relative phase of aberration was extracted from estimated cross spectra using a robust least-mean-square-error method based on an orthogonal expansion of the phase differences of neighboring wave forms as a function of frequency. Estimates of cross-spectrum phase from measurements of random scattering through a tissue-mimicking aberrator have confidence bands approximately +/- 5 degrees wide. Both phase and magnitude are in good agreement with a reference characterization obtained from a point scatterer.

  17. Optimizing signal output: effects of viscoelasticity and difference frequency on vibroacoustic radiation of tissue-mimicking phantoms

    Science.gov (United States)

    Namiri, Nikan K.; Maccabi, Ashkan; Bajwa, Neha; Badran, Karam W.; Taylor, Zachary D.; St. John, Maie A.; Grundfest, Warren S.; Saddik, George N.

    2018-02-01

    Vibroacoustography (VA) is an imaging technology that utilizes the acoustic response of tissues to a localized, low frequency radiation force to generate a spatially resolved, high contrast image. Previous studies have demonstrated the utility of VA for tissue identification and margin delineation in cancer tissues. However, the relationship between specimen viscoelasticity and vibroacoustic emission remains to be fully quantified. This work utilizes the effects of variable acoustic wave profiles on unique tissue-mimicking phantoms (TMPs) to maximize VA signal power according to tissue mechanical properties, particularly elasticity. A micro-indentation method was utilized to provide measurements of the elastic modulus for each biological replica. An inverse relationship was found between elastic modulus (E) and VA signal amplitude among homogeneous TMPs. Additionally, the difference frequency (Δf ) required to reach maximum VA signal correlated with specimen elastic modulus. Peak signal diminished with increasing Δf among the polyvinyl alcohol specimen, suggesting an inefficient vibroacoustic response by the specimen beyond a threshold of resonant Δf. Comparison of these measurements may provide additional information to improve tissue modeling, system characterization, as well as insights into the unique tissue composition of tumors in head and neck cancer patients.

  18. A case of acoustic neurinoma associated with chronic subdural hematoma after gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Sho, Atsuko; Asaeda, Masahiro; Ohtake, Minoru

    2002-01-01

    A 72-year-old female presented with a unique case of acoustic neurinoma with a cystic component followed by the chronic subdural hematoma manifesting as trigeminal neuralgia, facial palsy and trunchal ataxia 7 months after gamma knife radiosurgery. Magnetic resonance imaging demonstrated a loss of central contrast enhancement at the postoperative residual tumor mass and a large cyst associated with a hematoma in the subdural space. A right suboccipital craniectomy was performed. A biopsy of the mass and the membrane was performed following aspiration of the brown-reddish fluid collection. The histological diagnosis was acoustic neurinoma with a hemorrhagic necrosis. The membranous tissue mimicked an outer membrane obtained from chronic subdural hematoma. The postoperative course was satisfactory and preoperative symptom have been alleviated. In this case, the chronic subdural hematoma occurred at posterior fossa during the development of cysts caused by the radiosurgery, because the subdural space had been connected with the subarachnoid space after the first operation. The development of cysts or hematoma should be taken into consideration as possible complications following treatment with gamma knife radiosurgery for acoustic neurinomas. (author)

  19. A case of acoustic neurinoma associated with chronic subdural hematoma after gamma knife radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Sho, Atsuko; Asaeda, Masahiro; Ohtake, Minoru [Tottori Univ., Yonago (Japan). Inst. of Neurological Sciences] [and others

    2002-09-01

    A 72-year-old female presented with a unique case of acoustic neurinoma with a cystic component followed by the chronic subdural hematoma manifesting as trigeminal neuralgia, facial palsy and trunchal ataxia 7 months after gamma knife radiosurgery. Magnetic resonance imaging demonstrated a loss of central contrast enhancement at the postoperative residual tumor mass and a large cyst associated with a hematoma in the subdural space. A right suboccipital craniectomy was performed. A biopsy of the mass and the membrane was performed following aspiration of the brown-reddish fluid collection. The histological diagnosis was acoustic neurinoma with a hemorrhagic necrosis. The membranous tissue mimicked an outer membrane obtained from chronic subdural hematoma. The postoperative course was satisfactory and preoperative symptom have been alleviated. In this case, the chronic subdural hematoma occurred at posterior fossa during the development of cysts caused by the radiosurgery, because the subdural space had been connected with the subarachnoid space after the first operation. The development of cysts or hematoma should be taken into consideration as possible complications following treatment with gamma knife radiosurgery for acoustic neurinomas. (author)

  20. Clinical Experience With Radiation Therapy in the Management of Neurofibromatosis-Associated Central Nervous System Tumors

    International Nuclear Information System (INIS)

    Wentworth, Stacy; Pinn, Melva; Bourland, J. Daniel; Guzman, Allan F. de; Ekstrand, Kenneth; Ellis, Thomas L.; Glazier, Steven S.; McMullen, Kevin P.; Munley, Michael; Stieber, Volker W.; Tatter, Stephen B.; Shaw, Edward G.

    2009-01-01

    Purpose: Patients with neurofibromatosis (NF) develop tumors of the central nervous system (CNS). Radiation therapy (RT) is used to treat these lesions. To better define the efficacy of RT in these patients, we reviewed our 20-year experience. Methods and Materials: Eighteen patients with NF with CNS tumors were treated from 1986 to 2007. Median follow-up was 48 months. Progression was defined as growth or recurrence of an irradiated tumor on serial imaging. Progression-free survival (PFS) was measured from the date of RT completion to the date of last follow-up imaging study. Actuarial rates of overall survival (OS) and PFS were calculated according to the Kaplan-Meier method. Results: Eighty-two tumors in 18 patients were irradiated, with an average of five tumors/patient. Median age at treatment was 25 years (range, 4.3-64 years). Tumor types included acoustic neuroma (16%), ependymoma (6%), low-grade glioma (11%), meningioma (60%), and schwanomma/neurofibroma (7%). The most common indication for treatment was growth on serial imaging. Most patients (67%) received stereotactic radiosurgery (median dose, 1,200 cGy; range, 1,000-2,400 cGy). The OS rate at 5 years was 94%. Five-year PFS rates were 75% (acoustic neuroma), 100% (ependymoma), 75% (low-grade glioma), 86% (meningioma), and 100% (schwanomma/neurofibroma). Thirteen acoustic neuromas had a local control rate of 94% with a 50% hearing preservation rate. Conclusions: RT provided local control, OS, and PFS rates similar to or better than published data for tumors in non-NF patients. Radiation therapy should be considered in NF patients with imaging progression of CNS tumors

  1. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Cournane, S; Fagan, A J [Department of Medical Physics and Bioengineering, St James' s Hospital, Dublin 8 (Ireland); Cannon, L; Browne, J E [Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Kevin' s Street, Dublin 8 (Ireland)

    2010-10-07

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 {mu}m Al{sub 2}O{sub 3} and 3 {mu}m Al{sub 2}O{sub 3}, were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s{sup -1}, respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  2. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    Science.gov (United States)

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Gastric Adenomyoma: The Unexpected Mimicker

    Directory of Open Access Journals (Sweden)

    Marcela Adriana Duran Álvarez

    2017-01-01

    Full Text Available Gastric adenomyoma is a rare benign tumor composed of epithelial structures and smooth muscle stroma. Here, we report an unusual case of gastric adenomyoma mostly composed of smooth muscle that was incidentally found during a laparoscopic intervention. On radiology, it mimicked an acquired hypertrophic pyloric stenosis in an adult patient, and pathologically it resembled a pure smooth muscle hamartoma. Complete submission of the lesion for histology was necessary to find the epithelial component and make the right diagnosis. As a mimicker of benign and malignant entities, gastric adenomyoma is usually an unexpected finding after surgery. The aim of this report is to analyze this adenomyoma variant in the setting of an unexplained thickening of the gastric wall, with explanations concerning histogenesis and biological potential.

  4. An experimental device for characterizing degassing processes and related elastic fingerprints: Analog volcano seismo-acoustic observations

    Science.gov (United States)

    Spina, Laura; Morgavi, Daniele; Cannata, Andrea; Campeggi, Carlo; Perugini, Diego

    2018-05-01

    A challenging objective of modern volcanology is to quantitatively characterize eruptive/degassing regimes from geophysical signals (in particular seismic and infrasonic), for both research and monitoring purposes. However, the outcomes of the attempts made so far are still considered very uncertain because volcanoes remain inaccessible when deriving quantitative information on crucial parameters such as plumbing system geometry and magma viscosity. In order to improve our knowledge of volcanic systems, a novel experimental device, which is capable of mimicking volcanic degassing processes with different regimes and gas flow rates, and allowing for the investigation of the related seismo-acoustic emissions, was designed and developed. The benefits of integrating observations on real volcanoes with seismo-acoustic signals generated in laboratory are many and include (i) the possibility to fix the controlling parameters such as the geometry of the structure where the gas flows, the gas flow rate, and the fluid viscosity; (ii) the possibility of performing acoustic measurements at different azimuthal and zenithal angles around the opening of the analog conduit, hence constraining the radiation pattern of different acoustic sources; (iii) the possibility to measure micro-seismic signals in distinct points of the analog conduit; (iv) finally, thanks to the transparent structure, it is possible to directly observe the degassing pattern through the optically clear analog magma and define the degassing regime producing the seismo-acoustic radiations. The above-described device represents a step forward in the analog volcano seismo-acoustic measurements.

  5. Polymerization of a divalent/tetravalent metal-storing atom-mimicking dendrimer

    OpenAIRE

    Albrecht, Ken; Hirabayashi, Yuki; Otake, Masaya; Mendori, Shin; Tobari, Yuta; Azuma, Yasuo; Majima, Yutaka; Yamamoto, Kimihisa

    2016-01-01

    The phenylazomethine dendrimer (DPA) has a layer-by-layer electron density gradient that is an analog of the Bohr atom (atom mimicry). In combination with electron pair mimicry, the polymerization of this atom-mimicking dendrimer was achieved. The valency of the mimicked atom was controlled by changing the chemical structure of the dendrimer. By mimicking a divalent atom, a one-dimensional (1D) polymer was obtained, and by using a planar tetravalent atom mimic, a 2D polymer was obtained. Thes...

  6. Multicystic Hepatocarcinoma Mimicking Liver Abscess

    Directory of Open Access Journals (Sweden)

    Evangelos Falidas

    2013-01-01

    Full Text Available The diagnosis of hepatocellular carcinoma (HCC became easier in relation to the improved radiological examinations; however, the neoplasm may occur under atypical presentations mimicking other benign or malignant processes. Multicystic HCC mimicking a liver abscess associated with septic-type fever and leukocytosis is rare, has a poor prognosis, and poses diagnostic and therapeutic dilemmas. We present the case of an 80-year-old patient, who presented with fever, leukocytosis, and large cystic masses involving right and left lobes of the liver initially considered abscesses and finally diagnosed as HCC after open drainage and liver biopsy. Although the patient died on the tenth postoperative day due to pulmonary oedema, the authors emphasize the high index of suspicion needed in the diagnosis of this unusual presentation of HCC.

  7. Acoustic cloaking and transformation acoustics

    International Nuclear Information System (INIS)

    Chen Huanyang; Chan, C T

    2010-01-01

    In this review, we give a brief introduction to the application of the new technique of transformation acoustics, which draws on a correspondence between coordinate transformation and material properties. The technique is formulated for both acoustic waves and linear liquid surface waves. Some interesting conceptual devices can be designed for manipulating acoustic waves. For example, we can design acoustic cloaks that make an object invisible to acoustic waves, and the cloak can either encompass or lie outside the object to be concealed. Transformation acoustics, as an analog of transformation optics, can go beyond invisibility cloaking. As an illustration for manipulating linear liquid surface waves, we show that a liquid wave rotator can be designed and fabricated to rotate the wave front. The acoustic transformation media require acoustic materials which are anisotropic and inhomogeneous. Such materials are difficult to find in nature. However, composite materials with embedded sub-wavelength resonators can in principle be made and such 'acoustic metamaterials' can exhibit nearly arbitrary values of effective density and modulus tensors to satisfy the demanding material requirements in transformation acoustics. We introduce resonant sonic materials and Helmholtz resonators as examples of acoustic metamaterials that exhibit resonant behaviour in effective density and effective modulus. (topical review)

  8. Molecular genetic approach to human meningioma: loss of genes on chromosome 22

    International Nuclear Information System (INIS)

    Seizinger, B.R.; De La Monte, S.; Atkins, L.; Gusella, J.F.; Martuza, R.L.

    1987-01-01

    A molecular genetic approach employing polymorphic DNA markers has been used to investigate the role of chromosomal aberrations in meningioma, one of the most common tumors of the human nervous system. Comparison of the alleles detected by DNA markers in tumor DNA versus DNA from normal tissue revealed chromosomal alterations present in primary surgical specimens. In agreement with cytogenetic studies of cultured meningiomas, the most frequent alteration detected was loss of heterozygosity on chromosome 22. Forty of 51 patients were constitutionally heterozygous for at least one chromosome 22 DNA marker. Seventeen of the 40 constitutionally heterozygotic patients (43%) displayed hemizygosity for the corresponding marker in their meningioma tumor tissues. Loss of heterozygosity was also detected at a significantly lower frequency for markers on several other autosomes. In view of the striking association between acoustic neuroma and meningioma in bilateral acoustic neurofibromatosis and the discovery that acoustic neuromas display specific loss of genes on chromosome 22, the authors propose that a common mechanism involving chromosome 22 is operative in the development of both tumor types. Fine-structure mapping to reveal partial deletions in meningiomas may provide the means to clone and characterize a gene (or genes) of importance for tumorigenesis in this and possibly other clinically associated tumors of the human nervous system

  9. Experimental investigation and theoretical modelling of the nonlinear acoustical behaviour of a liver tissue and comparison with a tissue mimicking hydrogel.

    Science.gov (United States)

    Casciaro, Sergio; Demitri, Christian; Conversano, Francesco; Casciaro, Ernesto; Distante, Alessandro

    2008-02-01

    Native harmonics generated by nonlinear distortion of ultrasound during propagation in a medium may cause misinterpretations in spectral analysis when studying contrast agents. The aim of this paper is to quantitatively evaluate nonlinear propagation effects of diagnostic ultrasound pulses in biological tissues and to assess whether a cellulose-based hydrogel can be a suitable material for tissue mimicking purposes. Hydrogel and pig liver tissue samples of various thicknesses were insonified in a through-transmission set-up, employing 2.25-MHz pulses with different mechanical index (MI) values (range 0.06-0.60). Second harmonic and first harmonic amplitudes were extracted from spectra of received signals and their ratio was then used to compare hydrogel and liver behaviours. Resulting trends are very similar for sample thicknesses up to 8 cm and highlight a significant increase in nonlinearity for MI > 0.3, for both liver and hydrogel. A numerical procedure was also employed to calculate pressure distribution along the beam axis: these theoretical results showed a very good agreement with experimental data in the low pressure range, though failed in predicting the MI threshold. In conclusion, the hydrogel resulted to be a suitable material for manufacturing tissue mimicking phantoms, in particular to study contrast agent behaviour with a "low power approach".

  10. Immediate side effects of stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Werner-Wasik, Maria; Rudoler, Shari; Preston, Peter E.; Downes, Beverly M.; Andrews, David; Corn, Benjamin W.; Rosenstock, Jeffrey; Curran, Walter J.

    1996-01-01

    Purpose/Objective: Despite increased utilization of fractionated stereotactic radiation therapy (SRT) or stereotactic radiosurgery (SRS), the incidence and nature of immediate side effects (ISE) associated with these treatment techniques is not well defined. Materials and Methods: Intracranial lesions in 78 adult patients were treated with SRT or SRS, using a dedicated linear accelerator. They comprised 13 gliomas, 2 ependymomas, 19 metastatic tumors, 15 meningiomas, 12 acoustic neuromas, 4 pituitary adenomas, 1 optic neuroma, 1 chondrosarcoma and 11 arteriovenous malformations (AVM). SRT was used in 51 and SRS in 27 patients. Mean target volume was 9.0 cc. Eleven patients received prior external beam radiation therapy within 2 months before SRT/SRS. Any side effects occurring during and up to two weeks after radiation course were defined as ISE and were graded as mild, moderate or severe. The incidence of ISE and the significance of their association with several pretreatment variables were analyzed. Results: Overall, (28(78)) (35%) patients experienced one or more ISE. Most of ISE (87%) were mild and consisted of nausea (5), dizziness/vertigo (5), seizures (7) and new persistent headaches (17). Two episodes of worsening neurological deficit and 2 of orbital pain were graded as moderate. Two patients experienced severe ISE, requiring hospitalization (1 seizure and 1 worsening neurological deficit). ISE in 5 cases prompted computerized tomography of the brain which revealed increased perilesional edema in 3 cases. The incidence of ISE by diagnosis was as follows: 46% ((6(13))) for gliomas, 50% ((6(12))) for acoustic neuromas, 36% ((4(11))) for AVM, 33% ((5(15))) for meningiomas and 21% ((4(19))) for metastases. Increasing dose to the margin and increasing maximum dose were associated with a higher incidence of ISE (p=0.02 and 0.005, respectively). Prior recent conventional external beam radiation therapy, target volume, number of isocenters, collimator size, dose

  11. Neurofibromatosis type 2 and auditory brainstem implantation

    Institute of Scientific and Technical Information of China (English)

    XIAO Hong-jun; Dennis K.K. Au; Yau Hui; Chun-kuen Chow; Yiu-wah Fan; William Ignace Wei

    2007-01-01

    @@ Neurofibromatosis type 2 (NF-2) is one of the most common single gene disorders in the nervous system.For approximately 96% of patients with NF-2 present with bilateral Schwannomas involving the eighth cranial nerves, which may be accompanied by Schwannomas involving other cranial, spinal or peripheral nerves, NF-2 is also referred to as "bilateral acoustic neuromas".

  12. Clear cell carcinoma of the ovary mimicking struma ovarii and carcinoid tumor.

    Science.gov (United States)

    Alduaij, Ahmad; Quddus, M Ruhul

    2011-04-01

    Clear cell carcinomas are considered as high-grade tumor often with poor prognosis. We describe 2 cases of clear cell carcinomas of the ovary mimicking benign or less aggressive tumors encountered in the female genital track. The first case is mimicking a benign monodermal teratoma, the so-called struma ovarii, and the second mimicking a carcinoid tumor. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Characterization of Pump-Induced Acoustics in Space Launch System Main Propulsion System Liquid Hydrogen Feedline Using Airflow Test Data

    Science.gov (United States)

    Eberhart, C. J.; Snellgrove, L. M.; Zoladz, T. F.

    2015-01-01

    High intensity acoustic edgetones located upstream of the RS-25 Low Pressure Fuel Turbo Pump (LPFTP) were previously observed during Space Launch System (STS) airflow testing of a model Main Propulsion System (MPS) liquid hydrogen (LH2) feedline mated to a modified LPFTP. MPS hardware has been adapted to mitigate the problematic edgetones as part of the Space Launch System (SLS) program. A follow-on airflow test campaign has subjected the adapted hardware to tests mimicking STS-era airflow conditions, and this manuscript describes acoustic environment identification and characterization born from the latest test results. Fluid dynamics responsible for driving discrete excitations were well reproduced using legacy hardware. The modified design was found insensitive to high intensity edgetone-like discretes over the bandwidth of interest to SLS MPS unsteady environments. Rather, the natural acoustics of the test article were observed to respond in a narrowband-random/mixed discrete manner to broadband noise thought generated by the flow field. The intensity of these responses were several orders of magnitude reduced from those driven by edgetones.

  14. Myrmica Ants and Their Butterfly Parasites with Special Focus on the Acoustic Communication

    Directory of Open Access Journals (Sweden)

    F. Barbero

    2012-01-01

    Full Text Available About 10,000 arthropod species live as ants' social parasites and have evolved a number of mechanisms allowing them to penetrate and survive inside the ant nests. Myrmica colonies, in particular, are exploited by numerous social parasites, and the presence of their overwintering brood, as well as of their polygyny, contributes to make them more vulnerable to infestation. Butterflies of the genus Maculinea are among the most investigated Myrmica inquilines. These lycaenids are known for their very complex biological cycles. Maculinea species are obligated parasites that depend on a particular food plant and on a specific Myrmica species for their survival. Maculinea larvae are adopted by Myrmica ants, which are induced to take them into their nests by chemical mimicry. Then the parasite spends the following 11–23 months inside the ants' nest. Mimicking the acoustic emission of the queen ants, Maculinea parasites not only manage to become integrated, but attain highest rank within the colony. Here we review the biology of Maculinea/Myrmica system with a special focus on some recent breakthrough concerning their acoustical patterns.

  15. Acoustic Neuroma: Questions to Discuss with Your Doctor

    Science.gov (United States)

    ... or how a bite of bread tastes with dinner. Leverage your strengths for a more positive life Strengths are built-in capacities for certain thoughts, feelings, and behaviors. 5 ways to keep your memory sharp The way you live, what you eat and drink, and how you treat your body ...

  16. Tissue mimicking materials for a multi-imaging modality prostate phantom

    International Nuclear Information System (INIS)

    D'Souza, Warren D.; Madsen, Ernest L.; Unal, Orhan; Vigen, Karl K.; Frank, Gary R.; Thomadsen, Bruce R.

    2001-01-01

    Materials that simultaneously mimic soft tissue in vivo for magnetic resonance imaging (MRI), ultrasound (US), and computed tomography (CT) for use in a prostate phantom have been developed. Prostate and muscle mimicking materials contain water, agarose, lipid particles, protein, Cu ++ , EDTA, glass beads, and thimerosal (preservative). Fat was mimicked with safflower oil suffusing a random mesh (network) of polyurethane. Phantom material properties were measured at 22 deg. C. (22 deg. C is a typical room temperature at which phantoms are used.) The values of material properties should match, as well as possible, the values for tissues at body temperature, 37 deg. C. For MRI, the primary properties of interest are T1 and T2 relaxations times, for US they are the attenuation coefficient, propagation speed, and backscatter, and for CT, the x-ray attenuation. Considering the large number of parameters to be mimicked, rather good agreement was found with actual tissue values obtained from the literature. Using published values for prostate parenchyma, T1 and T2 at 37 deg. C and 40 MHz are estimated to be about 1100 and 98 ms, respectively. The CT number for in vivo prostate is estimated to be 45 HU (Hounsfield units). The prostate mimicking material has a T1 of 937 ms and a T2 of 88 ms at 22 deg. C and 40 MHz; the propagation speed and attenuation coefficient slope are 1540 m/s and 0.36 dB/cm/MHz, respectively, and the CT number of tissue mimicking prostate is 43 HU. Tissue mimicking (TM) muscle differs from TM prostate in the amount of dry weight agarose, Cu ++ , EDTA, and the quality and quantity of glass beads. The 18 μm glass beads used in TM muscle increase US backscatter and US attenuation; the presence of the beads also has some effect on T1 but no effect on T2. The composition of tissue-mimicking materials developed is such that different versions can be placed in direct contact with one another in a phantom with no long term change in US, MRI, or CT

  17. Virtual MRI endoscopy of the intracranial cerebrospinal fluid spaces

    International Nuclear Information System (INIS)

    Shigematsu, Y.; Korogi, Y.; Hirai, T.; Okuda, T.; Ikushima, I.; Sugahara, T.; Liang, L.; Ge, Y.; Takahashi, M.

    1998-01-01

    We used constructive interference in steady state (CISS) 3D Fourier transform (3DFT) MRI data sets to obtain three-dimensional (3D) virtual MRI endoscopic views of the intracranial cerebrospinal fluid (CSF) spaces, processing them with a commercially available perspective endoscopic algorithm. We investigated the potential of the intracranial virtual MRI endoscopy applied to visualisation of the pathology in 13 patients with surgically confirmed trigeminal neuralgia (3), hemifacial spasm (3), acoustic neuroma (3), suprasellar germinoma (1), Langerhans cell histiocytosis (1), lateral ventricle nodules (1) and pituitary dwarfism (1). All images were acquired using a 1.5-T imager employing a circular polarised head coil. The CISS-3DFT data sets were transferred to a workstation for processing with the perspective endoscopic algorithm. Postprocessing for virtual MRI endoscopy was possible for all data sets. The lesions in 12 patients, and their complex anatomical relationships with the surrounding structures, were well seen on the 3D images. A small acoustic neuroma in the internal auditory meatus was not seen using virtual endoscopy. Although virtual MRI endoscopy has limitations, it provides 3D images which cannot be acquired using any other procedure. (orig.)

  18. Virtual MRI endoscopy of the intracranial cerebrospinal fluid spaces

    Energy Technology Data Exchange (ETDEWEB)

    Shigematsu, Y.; Korogi, Y.; Hirai, T. [Kumamoto Univ. (Japan). Dept. of Radiology; Okuda, T.; Ikushima, I.; Sugahara, T.; Liang, L.; Ge, Y.; Takahashi, M.

    1998-10-01

    We used constructive interference in steady state (CISS) 3D Fourier transform (3DFT) MRI data sets to obtain three-dimensional (3D) virtual MRI endoscopic views of the intracranial cerebrospinal fluid (CSF) spaces, processing them with a commercially available perspective endoscopic algorithm. We investigated the potential of the intracranial virtual MRI endoscopy applied to visualisation of the pathology in 13 patients with surgically confirmed trigeminal neuralgia (3), hemifacial spasm (3), acoustic neuroma (3), suprasellar germinoma (1), Langerhans cell histiocytosis (1), lateral ventricle nodules (1) and pituitary dwarfism (1). All images were acquired using a 1.5-T imager employing a circular polarised head coil. The CISS-3DFT data sets were transferred to a workstation for processing with the perspective endoscopic algorithm. Postprocessing for virtual MRI endoscopy was possible for all data sets. The lesions in 12 patients, and their complex anatomical relationships with the surrounding structures, were well seen on the 3D images. A small acoustic neuroma in the internal auditory meatus was not seen using virtual endoscopy. Although virtual MRI endoscopy has limitations, it provides 3D images which cannot be acquired using any other procedure. (orig.) With 6 figs., 16 refs.

  19. Invasive Aspergillosis Mimicking Metastatic Lung Cancer

    Directory of Open Access Journals (Sweden)

    Michiel J. E. G. W. Vanfleteren

    2018-06-01

    Full Text Available In a patient with a medical history of cancer, the most probable diagnosis of an 18FDG-avid pulmonary mass combined with intracranial abnormalities on brain imaging is metastasized cancer. However, sometimes a differential diagnosis with an infectious cause such as aspergillosis can be very challenging as both cancer and infection are sometimes difficult to distinguish. Pulmonary aspergillosis can present as an infectious pseudotumour with clinical and imaging characteristics mimicking lung cancer. Even in the presence of cerebral lesions, radiological appearance of abscesses can look like brain metastasis. These similarities can cause significant diagnostic difficulties with a subsequent therapeutic delay and a potential adverse outcome. Awareness of this infectious disease that can mimic lung cancer, even in an immunocompetent patient, is important. We report a case of a 65-year-old woman with pulmonary aspergillosis disseminated to the brain mimicking metastatic lung cancer.

  20. Use of acoustic vortices in acoustic levitation

    DEFF Research Database (Denmark)

    Cutanda Henriquez, Vicente; Santillan, Arturo Orozco; Juhl, Peter Møller

    2009-01-01

    Acoustic fields are known to exert forces on the surfaces of objects. These forces are noticeable if the sound pressure is sufficiently high. Two phenomena where acoustic forces are relevant are: i) acoustic levitation, where strong standing waves can hold small objects at certain positions......, counterbalancing their weight, and ii) acoustic vortices, spinning sound fields that can impinge angular momentum and cause rotation of objects. In this contribution, both force-creating sound fields are studied by means of numerical simulations. The Boundary Element Method is employed to this end. The simulation...... of acoustical vortices uses an efficient numerical implementation based on the superposition of two orthogonal sound fields with a delay of 90° between them. It is shown that acoustic levitation and the use of acoustic vortices can be combined to manipulate objects in an efficient and controlled manner without...

  1. A Comparative Analysis of Ability of Mimicking Portfolios in Representing the Background Factors

    OpenAIRE

    Asgharian, Hossein

    2004-01-01

    Our aim is to give a comparative analysis of ability of different factor mimicking portfolios in representing the background factors. Our analysis contains a cross-sectional regression approach, a time-series regression approach and a portfolio approach for constructing factor mimicking portfolios. The focus of the analysis is the power of mimicking portfolios in the asset pricing models. We conclude that the time series regression approach, with the book-to-market sorted portfolios as the ba...

  2. Acoustic emission

    International Nuclear Information System (INIS)

    Nichols, R.W.

    1976-01-01

    The volume contains six papers which together provide an overall review of the inspection technique known as acoustic emission or stress wave emission. The titles are: a welder's introduction to acoustic emission technology; use of acoustic emission for detection of defects as they arise during fabrication; examples of laboratory application and assessment of acoustic emission in the United Kingdom; (Part I: acoustic emission behaviour of low alloy steels; Part II: fatigue crack assessment from proof testing and continuous monitoring); inspection of selected areas of engineering structures by acoustic emission; Japanese experience in laboratory and practical applications of acoustic emission to welded structures; and ASME acoustic emission code status. (U.K.)

  3. Translational illusion of acoustic sources by transformation acoustics.

    Science.gov (United States)

    Sun, Fei; Li, Shichao; He, Sailing

    2017-09-01

    An acoustic illusion of creating a translated acoustic source is designed by utilizing transformation acoustics. An acoustic source shifter (ASS) composed of layered acoustic metamaterials is designed to achieve such an illusion. A practical example where the ASS is made with naturally available materials is also given. Numerical simulations verify the performance of the proposed device. The designed ASS may have some applications in, e.g., anti-sonar detection.

  4. Leiomyoma of the distal oesophagus mimicking achalasia

    NARCIS (Netherlands)

    Idenburg, F. J.; Akkermans, L. M.; Smout, A. J.; Kooijman, C. D.; Obertop, H.

    1991-01-01

    An unusual case of a patient with symptoms suggestive of oesophageal achalasia is described. Most oesophageal tumour growths causing secondary achalasia are associated with malignant tumours. This patient had a large oesophageal leiomyoma closely mimicking achalasia. Treatment consisted of

  5. Linear accelerator based stereotactic radiosurgery with micro multi-leaf collimator : technological advancement in precision radiotherapy

    International Nuclear Information System (INIS)

    Dayananda, S.; Kinhikar, R.A.; Saju, Sherley; Deshpande, D.D.; Jalali, R.; Sarin, R.; Shrivastava, S.K.; Dinshaw, K.A.

    2003-01-01

    Stereotactic Radiosurgery (SRS) is an advancement on precision radiotherapy, in which stereo tactically guided localized high dose is delivered to the lesion (target) in a single fraction, while sparing the surrounding normal tissue. Radiosurgery has been used to treat variety of benign and malignant lesions as well as functional disorders in brain such as arteriovenous malformation (AVM), acoustic neuroma, solitary primary brain tumor, single metastasis, pituitary adenoma etc

  6. Fundamentals of Acoustics. Psychoacoustics and Hearing. Acoustical Measurements

    Science.gov (United States)

    Begault, Durand R.; Ahumada, Al (Technical Monitor)

    1997-01-01

    These are 3 chapters that will appear in a book titled "Building Acoustical Design", edited by Charles Salter. They are designed to introduce the reader to fundamental concepts of acoustics, particularly as they relate to the built environment. "Fundamentals of Acoustics" reviews basic concepts of sound waveform frequency, pressure, and phase. "Psychoacoustics and Hearing" discusses the human interpretation sound pressure as loudness, particularly as a function of frequency. "Acoustic Measurements" gives a simple overview of the time and frequency weightings for sound pressure measurements that are used in acoustical work.

  7. Communication Acoustics

    DEFF Research Database (Denmark)

    Blauert, Jens

    Communication Acoustics deals with the fundamentals of those areas of acoustics which are related to modern communication technologies. Due to the advent of digital signal processing and recording in acoustics, these areas have enjoyed an enormous upswing during the last 4 decades. The book...... the book a source of valuable information for those who want to improve or refresh their knowledge in the field of communication acoustics - and to work their way deeper into it. Due to its interdisciplinary character Communication Acoustics is bound to attract readers from many different areas, such as......: acoustics, cognitive science, speech science, and communication technology....

  8. Effects of acoustic radiation force and shear waves for absorption and stiffness sensing in ultrasound modulated optical tomography.

    Science.gov (United States)

    Li, Rui; Elson, Daniel S; Dunsby, Chris; Eckersley, Robert; Tang, Meng-Xing

    2011-04-11

    Ultrasound-modulated optical tomography (UOT) combines optical contrast with ultrasound spatial resolution and has great potential for soft tissue functional imaging. One current problem with this technique is the weak optical modulation signal, primarily due to strong optical scattering in diffuse media and minimal acoustically induced modulation. The acoustic radiation force (ARF) can create large particle displacements in tissue and has been shown to be able to improve optical modulation signals. However, shear wave propagation induced by the ARF can be a significant source of nonlocal optical modulation which may reduce UOT spatial resolution and contrast. In this paper, the time evolution of shear waves was examined on tissue mimicking-phantoms exposed to 5 MHz ultrasound and 532 nm optical radiation and measured with a CCD camera. It has been demonstrated that by generating an ARF with an acoustic burst and adjusting both the timing and the exposure time of the CCD measurement, optical contrast and spatial resolution can be improved by ~110% and ~40% respectively when using the ARF rather than 5 MHz ultrasound alone. Furthermore, it has been demonstrated that this technique simultaneously detects both optical and mechanical contrast in the medium and the optical and mechanical contrast can be distinguished by adjusting the CCD exposure time. © 2011 Optical Society of America

  9. Mimicking Seawater For Culturing Marine Bacteria

    DEFF Research Database (Denmark)

    Rygaard, Anita Mac; Sonnenschein, Eva; Gram, Lone

    2015-01-01

    Only about 1% of marine bacteria have been brought into culture using traditional techniques. The purpose of this study was to investigate if mimicking the natural bacterial environment can increase culturability.We used marine substrates containing defined algal polymers or gellan gum as solidif......Only about 1% of marine bacteria have been brought into culture using traditional techniques. The purpose of this study was to investigate if mimicking the natural bacterial environment can increase culturability.We used marine substrates containing defined algal polymers or gellan gum...... as solidifying agents, and enumerated bacteria from seawater and algal exudates. We tested if culturability could be influenced by addition of quorum sensing signals (AHLs). All plates were incubated at 15°C. Bacterial counts (CFU/g) from algal exudates from brown algae were highest on media containing algal...... polymers. In general, bacteria isolated from algal exudates preferred more rich media than bacteria isolated from seawater. Overall, culturability ranged from 0.01 to 0.8% as compared to total cell count. Substitution of agar with gellan gum increased the culturability of seawater bacteria approximately...

  10. Acoustic source for generating an acoustic beam

    Science.gov (United States)

    Vu, Cung Khac; Sinha, Dipen N.; Pantea, Cristian

    2016-05-31

    An acoustic source for generating an acoustic beam includes a housing; a plurality of spaced apart piezo-electric layers disposed within the housing; and a non-linear medium filling between the plurality of layers. Each of the plurality of piezoelectric layers is configured to generate an acoustic wave. The non-linear medium and the plurality of piezo-electric material layers have a matching impedance so as to enhance a transmission of the acoustic wave generated by each of plurality of layers through the remaining plurality of layers.

  11. Acoustic calibration apparatus for calibrating plethysmographic acoustic pressure sensors

    Science.gov (United States)

    Zuckerwar, Allan J. (Inventor); Davis, David C. (Inventor)

    1995-01-01

    An apparatus for calibrating an acoustic sensor is described. The apparatus includes a transmission material having an acoustic impedance approximately matching the acoustic impedance of the actual acoustic medium existing when the acoustic sensor is applied in actual in-service conditions. An elastic container holds the transmission material. A first sensor is coupled to the container at a first location on the container and a second sensor coupled to the container at a second location on the container, the second location being different from the first location. A sound producing device is coupled to the container and transmits acoustic signals inside the container.

  12. Immediate side effects of stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Werner-Wasik, Maria; Rudoler, Shari; Preston, Peter E.; Hauck, Walter W.; Downes, Beverly M.; Leeper, Dennis; Andrews, David; Corn, Benjamin W.; Curran, Walter J.

    1999-01-01

    Purpose: Despite increased utilization of fractionated stereotactic radiation therapy (SRT) or stereotactic radiosurgery (SRS), the incidence and nature of immediate side effects (ISE) associated with these treatment techniques are not well defined. We report immediate side effects from a series of 78 patients. Materials and Methods: Intracranial lesions in 78 adult patients were treated with SRT or SRS, using a dedicated linear accelerator. Those lesions included 13 gliomas, 2 ependymomas, 19 metastatic tumors, 15 meningiomas, 12 acoustic neuromas, 4 pituitary adenomas, 1 optic neuroma, 1 chondrosarcoma, and 11 arteriovenous malformations (AVM). SRT was used in 51 and SRS in 27 patients. Mean target volume was 9.0 cc. Eleven patients received prior external-beam radiation therapy within 2 months before SRT/SRS. Any side effects occurring during and up to 2 weeks after the course of radiation were defined as ISE and were graded as mild, moderate, or severe. The incidence of ISE and the significance of their association with several treatment and pretreatment variables were analyzed. Results: Overall, 28 (35%) of 78 patients experienced one or more ISE. Most of the ISE (87%) were mild, and consisted of nausea (in 5), dizziness/vertigo (in 5), seizures (in 6), and new persistent headaches (in 17). Two episodes of worsening neurological deficit and 2 of orbital pain were graded as moderate. Two patients experienced severe ISE, requiring hospitalization (1 seizure and 1 worsening neurological deficit). ISE in 6 cases prompted computerized tomography of the brain, which revealed increased perilesional edema in 3 cases. The incidence of ISE by diagnosis was as follows: 46% (6 of 13) for gliomas, 50% (6 of 12) for acoustic neuromas, 36% (4 of 11) for AVM, 33% (5 of 15) for meningiomas, and 21% (4 of 19) for metastases. A higher incidence of dizziness/vertigo (4 of 12 = 33%) was seen among acoustic neuroma patients than among other patients (p < 0.01). There was no

  13. Observations at the CNS-PNS border of ventral roots connected to a neuroma

    Directory of Open Access Journals (Sweden)

    Sten Remahl

    2010-10-01

    Full Text Available Previous studies have shown that numerous sprouts originating from a neuroma, after nerve injury in neonatal animals, can invade spinal nerve roots. In this study the border between the central and peripheral nervous system (CNS-PNS border of ventral roots in kittens was examined with both light and electron microscopy after early postnatal sciatic nerve resection. A transient ingrowth of substance P positive axons was observed into the CNS, but no spouts remained 6 weeks after the injury. Using serial sections and electron microscopy it was possible to identify small bundles of unmyelinated axons that penetrated from the root fascicles for a short distance into the CNS. These axons ended blindly, sometimes with a growth cone-like terminal swelling filled with vesicles. The axon bundles were accompanied by p75 positive cells in both the root fascicles and the pia mater, but not in the CNS. It may thus be suggested that neurotrophin presenting p75 positive cells could facilitate axonal growth into the pia mater and that the lack of such cells in the CNS compartment might contribute to the failure of growth into the CNS. A maldevelopment of myelin sheaths at the CNS-PNS border of motor axons was observed and it seems possible that this could have consequences for the propagation of action potential across this region after neonatal nerve injury.

  14. Measurement of guided mode wavenumbers in soft tissue–bone mimicking phantoms using ultrasonic axial transmission

    International Nuclear Information System (INIS)

    Chen Jiangang; Su Zhongqing; Cheng Li; Foiret, Josquin; Minonzio, Jean-Gabriel; Talmant, Maryline; Laugier, Pascal

    2012-01-01

    Human soft tissue is an important factor that influences the assessment of human long bones using quantitative ultrasound techniques. To investigate such influence, a series of soft tissue–bone phantoms (a bone-mimicking plate coated with a layer of water, glycerol or silicon rubber) were ultrasonically investigated using a probe with multi-emitter and multi-receiver arrays in an axial transmission configuration. A singular value decomposition signal processing technique was applied to extract the frequency-dependent wavenumbers of several guided modes. The results indicate that the presence of a soft tissue-mimicking layer introduces additional guided modes predicted by a fluid waveguide model. The modes propagating in the bone-mimicking plate covered by the soft-tissue phantom are only slightly modified compared to their counterparts in the free bone-mimicking plate, and they are still predicted by an elastic transverse isotropic two-dimensional waveguide. Altogether these observations suggest that the soft tissue–bone phantoms can be modeled as two independent waveguides. Even in the presence of the overlying soft tissue-mimicking layer, the modes propagating in the bone-mimicking plate can still be extracted and identified. These results suggest that our approach can be applied for the purpose of the characterization of the material and structural properties of cortical bone. (paper)

  15. Acoustically Induced Vibration of Structures: Reverberant Vs. Direct Acoustic Testing

    Science.gov (United States)

    Kolaini, Ali R.; O'Connell, Michael R.; Tsoi, Wan B.

    2009-01-01

    Large reverberant chambers have been used for several decades in the aerospace industry to test larger structures such as solar arrays and reflectors to qualify and to detect faults in the design and fabrication of spacecraft and satellites. In the past decade some companies have begun using direct near field acoustic testing, employing speakers, for qualifying larger structures. A limited test data set obtained from recent acoustic tests of the same hardware exposed to both direct and reverberant acoustic field testing has indicated some differences in the resulting structural responses. In reverberant acoustic testing, higher vibration responses were observed at lower frequencies when compared with the direct acoustic testing. In the case of direct near field acoustic testing higher vibration responses appeared to occur at higher frequencies as well. In reverberant chamber testing and direct acoustic testing, standing acoustic modes of the reverberant chamber or the speakers and spacecraft parallel surfaces can strongly couple with the fundamental structural modes of the test hardware. In this paper data from recent acoustic testing of flight hardware, that yielded evidence of acoustic standing wave coupling with structural responses, are discussed in some detail. Convincing evidence of the acoustic standing wave/structural coupling phenomenon will be discussed, citing observations from acoustic testing of a simple aluminum plate. The implications of such acoustic coupling to testing of sensitive flight hardware will be discussed. The results discussed in this paper reveal issues with over or under testing of flight hardware that could pose unanticipated structural and flight qualification issues. Therefore, it is of paramount importance to understand the structural modal coupling with standing acoustic waves that has been observed in both methods of acoustic testing. This study will assist the community to choose an appropriate testing method and test setup in

  16. Schwannoma of the left brachial plexus mimicking a ...

    African Journals Online (AJOL)

    Schwannoma of the left brachial plexus mimicking a cervicomediastinal ... Her voice was hoarse but there was no eye signs suggestive of thyrotoxicosis. ... A presumptive diagnosis of thyroid carcinoma with retrosternal extension was made.

  17. Interior acoustic cloak

    Directory of Open Access Journals (Sweden)

    Wael Akl

    2014-12-01

    Full Text Available Acoustic cloaks have traditionally been intended to externally surround critical objects to render these objects acoustically invisible. However, in this paper, the emphasis is placed on investigating the application of the acoustic cloaks to the interior walls of acoustic cavities in an attempt to minimize the noise levels inside these cavities. In this manner, the acoustic cloaks can serve as a viable and efficient alternative to the conventional passive noise attenuation treatments which are invariably heavy and bulky. The transformation acoustics relationships that govern the operation of this class of interior acoustic cloaks are presented. Physical insights are given to relate these relationships to the reasons behind the effectiveness of the proposed interior acoustic cloaks. Finite element models are presented to demonstrate the characteristics of interior acoustic cloaks used in treating the interior walls of circular and square cavities both in the time and frequency domains. The obtained results emphasize the effectiveness of the proposed interior cloaks in eliminating the reflections of the acoustic waves from the walls of the treated cavities and thereby rendering these cavities acoustically quiet. It is important to note here that the proposed interior acoustic cloaks can find applications in acoustic cavities such as aircraft cabins and auditoriums as well as many other critical applications.

  18. Responsive acoustic surfaces

    DEFF Research Database (Denmark)

    Peters, Brady; Tamke, Martin; Nielsen, Stig Anton

    2011-01-01

    Acoustic performance is defined by the parameter of reverberation time; however, this does not capture the acoustic experience in some types of open plan spaces. As many working and learning activities now take place in open plan spaces, it is important to be able to understand and design...... for the acoustic conditions of these spaces. This paper describes an experimental research project that studied the design processes necessary to design for sound. A responsive acoustic surface was designed, fabricated and tested. This acoustic surface was designed to create specific sonic effects. The design...... was simulated using custom integrated acoustic software and also using Odeon acoustic analysis software. The research demonstrates a method for designing space- and sound-defining surfaces, defines the concept of acoustic subspace, and suggests some new parameters for defining acoustic subspaces....

  19. Flat acoustic lens by acoustic grating with curled slits

    KAUST Repository

    Peng, Pai

    2014-10-01

    We design a flat sub-wavelength lens that can focus acoustic wave. We analytically study the transmission through an acoustic grating with curled slits, which can serve as a material with tunable impedance and refractive index for acoustic waves. The effective parameters rely on the geometry of the slits and are independent of frequency. A flat acoustic focusing lens by such acoustic grating with gradient effective refractive index is designed. The focusing effect is clearly observed in simulations and well predicted by the theory. We demonstrate that despite the large impedance mismatch between the acoustic lens and the matrix, the intensity at the focal point is still high due to Fabry-Perot resonance.

  20. Parametric Room Acoustic workflows with real-time acoustic simulation

    DEFF Research Database (Denmark)

    Parigi, Dario

    2017-01-01

    The paper investigates and assesses the opportunities that real-time acoustic simulation offer to engage in parametric acoustics workflow and to influence architectural designs from early design stages......The paper investigates and assesses the opportunities that real-time acoustic simulation offer to engage in parametric acoustics workflow and to influence architectural designs from early design stages...

  1. World Health Organization, radiofrequency radiation and health - a hard nut to crack (Review)

    OpenAIRE

    Hardell, Lennart

    2017-01-01

    In May 2011 the International Agency for Research on Cancer (IARC) evaluated cancer risks from radiofrequency (RF) radiation. Human epidemiological studies gave evidence of increased risk for glioma and acoustic neuroma. RF radiation was classified as Group 2B, a possible human carcinogen. Further epidemiological, animal and mechanistic studies have strengthened the association. In spite of this, in most countries little or nothing has been done to reduce exposure and educate people on health...

  2. Mobile phones and head tumours. The discrepancies in cause-effect relationships in the epidemiological studies - how do they arise?

    OpenAIRE

    Levis, Angelo G; Minicuci, Nadia; Ricci, Paolo; Gennaro, Valerio; Garbisa, Spiridione

    2011-01-01

    Abstract Background Whether or not there is a relationship between use of mobile phones (analogue and digital cellulars, and cordless) and head tumour risk (brain tumours, acoustic neuromas, and salivary gland tumours) is still a matter of debate; progress requires a critical analysis of the methodological elements necessary for an impartial evaluation of contradictory studies. Methods A close examination of the protocols and results from all case-control and cohort studies, pooled- and meta-...

  3. Tongue metastasis mimicking an abscess.

    Science.gov (United States)

    Mavili, Ertuğrul; Oztürk, Mustafa; Yücel, Tuba; Yüce, Imdat; Cağli, Sedat

    2010-03-01

    Primary tumors metastasizing to the oral cavity are extremely rare. Lung is one of the most common primary sources of metastases to the tongue. Although the incidence of lung cancer is increasing, tongue metastasis as the initial presentation of the tumor remains uncommon. Due to the rarity of tongue metastasis, little is known about its imaging findings. Herein we report the magnetic resonance imaging and clinical findings of a lingual metastasis, mimicking an abscess, from a primary lung cancer.

  4. Iliacus Abscess with Radiculopathy Mimicking Herniated Nucleus ...

    African Journals Online (AJOL)

    2016-05-02

    May 2, 2016 ... radiculopathy mimicking herniated nucleus pulposus: Aadditional diagnostic value of magnetic resonance imaging. Niger J Clin Pract. 2017;20:392-3. This is an open access article distributed under the terms of the Creative Commons. Attribution-Non Commercial-Share Alike 3.0 License, which allows ...

  5. Acoustic Radiation Force-Induced Creep-Recovery (ARFICR): A Noninvasive Method to Characterize Tissue Viscoelasticity.

    Science.gov (United States)

    Amador Carrascal, Carolina; Chen, Shigao; Urban, Matthew W; Greenleaf, James F

    2018-01-01

    Ultrasound shear wave elastography is a promising noninvasive, low cost, and clinically viable tool for liver fibrosis staging. Current shear wave imaging technologies on clinical ultrasound scanners ignore shear wave dispersion and use a single group velocity measured over the shear wave bandwidth to estimate tissue elasticity. The center frequency and bandwidth of shear waves induced by acoustic radiation force depend on the ultrasound push beam (push duration, -number, etc.) and the viscoelasticity of the medium, and therefore are different across scanners from different vendors. As a result, scanners from different vendors may give different tissue elasticity measurements within the same patient. Various methods have been proposed to evaluate shear wave dispersion to better estimate tissue viscoelasticity. A rheological model such as the Kelvin-Voigt model is typically fitted to the shear wave dispersion to solve for the elasticity and viscosity of tissue. However, these rheological models impose strong assumptions about frequency dependence of elasticity and viscosity. Here, we propose a new method called Acoustic Radiation Force Induced Creep-Recovery (ARFICR) capable of quantifying rheological model-independent measurements of elasticity and viscosity for more robust tissue health assessment. In ARFICR, the creep-recovery time signal at the focus of the push beam is used to calculate the relative elasticity and viscosity (scaled by an unknown constant) over a wide frequency range. Shear waves generated during the ARFICR measurement are also detected and used to calculate the shear wave velocity at its center frequency, which is then used to calibrate the relative elasticity and viscosity to absolute elasticity and viscosity. In this paper, finite-element method simulations and experiments in tissue mimicking phantoms are used to validate and characterize the extent of viscoelastic quantification of ARFICR. The results suggest that ARFICR can measure tissue

  6. Clerodendrum inerme Leaf Extract Alleviates Animal Behaviors, Hyperlocomotion, and Prepulse Inhibition Disruptions, Mimicking Tourette Syndrome and Schizophrenia

    Directory of Open Access Journals (Sweden)

    Hon-Lie Chen

    2012-01-01

    Full Text Available Previously, we found a patient with intractable motor tic disorder, a spectrum of Tourette syndrome (TS, responsive to the ground leaf juice of Clerodendrum inerme (CI. Here, we examined the effect of the ethanol extract of CI leaves (CI extract on animal behaviors mimicking TS, hyperlocomotion, and sensorimotor gating deficit. The latter is also observed in schizophrenic patients and can be reflected by a disruption of prepulse inhibition of acoustic startle response (PPI in animal models induced by methamphetamine and NMDA channel blockers (ketamine or MK-801, based on hyperdopaminergic and hypoglutamatergic hypotheses, respectively. CI extract (10–300 mg/kg, i.p. dose-dependently inhibited hyperlocomotion induced by methamphetamine (2 mg/kg, i.p. and PPI disruptions induced by methamphetamine, ketamine (30 mg/kg, i.p., and MK-801 (0.3 mg/kg, i.p. but did not affect spontaneous locomotor activity, rotarod performance, and grip force. These results suggest that CI extract can relieve hyperlocomotion and improve sensorimotor gating deficit, supporting the therapeutic potential of CI for TS and schizophrenia.

  7. A numerical study on acoustic behavior in gas turbine combustor with acoustic resonator

    International Nuclear Information System (INIS)

    Park, I Sun; Sohn, Chae Hoon

    2005-01-01

    Acoustic behavior in gas turbine combustor with acoustic resonator is investigated numerically by adopting linear acoustic analysis. Helmholtz-type resonator is employed as acoustic resonator to suppress acoustic instability passively. The tuning frequency of acoustic resonator is adjusted by varying its length. Through harmonic analysis, acoustic-pressure responses of chamber to acoustic excitation are obtained and the resonant acoustic modes are identified. Acoustic damping effect of acoustic resonator is quantified by damping factor. As the tuning frequency of acoustic resonator approaches the target frequency of the resonant mode to be suppressed, mode split from the original resonant mode to lower and upper modes appears and thereby complex patterns of acoustic responses show up. Considering mode split and damping effect as a function of tuning frequency, it is desirable to make acoustic resonator tuned to broad-band frequencies near the maximum frequency of those of the possible upper modes

  8. Acoustical Imaging

    CERN Document Server

    Litniewski, Jerzy; Kujawska, Tamara; 31st International Symposium on Acoustical Imaging

    2012-01-01

    The International Symposium on Acoustical Imaging is a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. This interdisciplinary Symposium has been taking place continuously since 1968. In the course of the years the proceedings volumes in the Acoustical Imaging Series have become a reference for cutting-edge research in the field. In 2011 the 31st International Symposium on Acoustical Imaging was held in Warsaw, Poland, April 10-13. Offering both a broad perspective on the state-of-the-art as well as  in-depth research contributions by the specialists in the field, this Volume 31 in the Series contains an excellent collection of papers in six major categories: Biological and Medical Imaging Physics and Mathematics of Acoustical Imaging Acoustic Microscopy Transducers and Arrays Nondestructive Evaluation and Industrial Applications Underwater Imaging

  9. Clozapine Intoxication Mimicking Acute Stroke

    Directory of Open Access Journals (Sweden)

    Joshua D. Villarreal

    2018-04-01

    Full Text Available Clozapine is an atypical antipsychotic drug prescribed for treatment-resistant schizophrenia. The risk of adverse hematologic, cardiovascular, and neurologic effects has tempered its use, and reports of overdoses remain rare. We report a case of accidental acute clozapine intoxication in a clozapine-naïve patient, who presented with symptoms mimicking acute stroke and later developed status epilepticus. Clozapine intoxication is a rare presentation in the emergency department with potential for iatrogenic harm if not correctly identified.

  10. Topological Acoustics

    Science.gov (United States)

    Yang, Zhaoju; Gao, Fei; Shi, Xihang; Lin, Xiao; Gao, Zhen; Chong, Yidong; Zhang, Baile

    2015-03-01

    The manipulation of acoustic wave propagation in fluids has numerous applications, including some in everyday life. Acoustic technologies frequently develop in tandem with optics, using shared concepts such as waveguiding and metamedia. It is thus noteworthy that an entirely novel class of electromagnetic waves, known as "topological edge states," has recently been demonstrated. These are inspired by the electronic edge states occurring in topological insulators, and possess a striking and technologically promising property: the ability to travel in a single direction along a surface without backscattering, regardless of the existence of defects or disorder. Here, we develop an analogous theory of topological fluid acoustics, and propose a scheme for realizing topological edge states in an acoustic structure containing circulating fluids. The phenomenon of disorder-free one-way sound propagation, which does not occur in ordinary acoustic devices, may have novel applications for acoustic isolators, modulators, and transducers.

  11. Deep Granuloma Annulare Mimicking Inflamed Cysts in a Teenager.

    Science.gov (United States)

    Guo, Emily L; Degesys, Catherine A; Jahan-Tigh, Richard; Chan, Audrey

    2017-07-01

    We describe deep granuloma annulare (DGA) of the forehead mimicking inflamed cysts. Reactive inflammation and sterile purulent drainage may be an underrecognized feature of DGA. © 2017 Wiley Periodicals, Inc.

  12. High transmission acoustic focusing by impedance-matched acoustic meta-surfaces

    KAUST Repository

    Al Jahdali, Rasha

    2016-01-19

    Impedance is an important issue in the design of acoustic lenses because mismatched impedance is detrimental to real focusing applications. Here, we report two designs of acoustic lenses that focus acoustic waves in water and air, respectively. They are tailored by acoustic meta-surfaces, which are rigid thin plates decorated with periodically distributed sub-wavelength slits. Their respective building blocks are constructed from the coiling-up spaces in water and the layered structures in air. Analytic analysis based on coupled-mode theory and transfer matrix reveals that the impedances of the lenses are matched to those of the background media. With these impedance-matched acoustic lenses, we demonstrate the acoustic focusing effect by finite-element simulations.

  13. High transmission acoustic focusing by impedance-matched acoustic meta-surfaces

    KAUST Repository

    Al Jahdali, Rasha; Wu, Ying

    2016-01-01

    Impedance is an important issue in the design of acoustic lenses because mismatched impedance is detrimental to real focusing applications. Here, we report two designs of acoustic lenses that focus acoustic waves in water and air, respectively. They are tailored by acoustic meta-surfaces, which are rigid thin plates decorated with periodically distributed sub-wavelength slits. Their respective building blocks are constructed from the coiling-up spaces in water and the layered structures in air. Analytic analysis based on coupled-mode theory and transfer matrix reveals that the impedances of the lenses are matched to those of the background media. With these impedance-matched acoustic lenses, we demonstrate the acoustic focusing effect by finite-element simulations.

  14. On measurement of the acoustic nonlinearity parameter using the finite amplitude insertion substitution (FAIS) technique

    Science.gov (United States)

    Zeqiri, Bajram; Cook, Ashley; Rétat, Lise; Civale, John; ter Haar, Gail

    2015-04-01

    The acoustic nonlinearity parameter, B/A, is an important parameter which defines the way a propagating finite amplitude acoustic wave progressively distorts when travelling through any medium. One measurement technique used to determine its value is the finite amplitude insertion substitution (FAIS) method which has been applied to a range of liquid, tissue and tissue-like media. Importantly, in terms of the achievable measurement uncertainties, it is a relative technique. This paper presents a detailed study of the method, employing a number of novel features. The first of these is the use of a large area membrane hydrophone (30 mm aperture) which is used to record the plane-wave component of the acoustic field. This reduces the influence of diffraction on measurements, enabling studies to be carried out within the transducer near-field, with the interrogating transducer, test cell and detector positioned close to one another, an attribute which assists in controlling errors arising from nonlinear distortion in any intervening water path. The second feature is the development of a model which estimates the influence of finite-amplitude distortion as the acoustic wave travels from the rear surface of the test cell to the detector. It is demonstrated that this can lead to a significant systematic error in B/A measurement whose magnitude and direction depends on the acoustic property contrast between the test material and the water-filled equivalent cell. Good qualitative agreement between the model and experiment is reported. B/A measurements are reported undertaken at (20 ± 0.5) °C for two fluids commonly employed as reference materials within the technical literature: Corn Oil and Ethylene Glycol. Samples of an IEC standardised agar-based tissue-mimicking material were also measured. A systematic assessment of measurement uncertainties is presented giving expanded uncertainties in the range ±7% to ±14%, expressed at a confidence level close to 95

  15. Vibro-acoustics

    CERN Document Server

    Nilsson, Anders

    2015-01-01

    This three-volume book gives a thorough and comprehensive presentation of vibration and acoustic theories. Different from traditional textbooks which typically deal with some aspects of either acoustic or vibration problems, it is unique of this book to combine those two correlated subjects together. Moreover, it provides fundamental analysis and mathematical descriptions for several crucial phenomena of Vibro-Acoustics which are quite useful in noise reduction, including how structures are excited, energy flows from an excitation point to a sound radiating surface, and finally how a structure radiates noise to a surrounding fluid. Many measurement results included in the text make the reading interesting and informative. Problems/questions are listed at the end of each chapter and the solutions are provided. This will help the readers to understand the topics of Vibro-Acoustics more deeply. The book should be of interest to anyone interested in sound and vibration, vehicle acoustics, ship acoustics and inter...

  16. Acoustics an introduction

    CERN Document Server

    Kuttruff, Heinrich

    2006-01-01

    This definitive textbook provides students with a comprehensive introduction to acoustics. Beginning with the basic physical ideas, Acoustics balances the fundamentals with engineering aspects, applications and electroacoustics, also covering music, speech and the properties of human hearing. The concepts of acoustics are exposed and applied in:room acousticssound insulation in buildingsnoise controlunderwater sound and ultrasoundScientifically thorough, but with mathematics kept to a minimum, Acoustics is the perfect introduction to acoustics for students at any level of mechanical, electrical or civil engineering courses and an accessible resource for architects, musicians or sound engineers requiring a technical understanding of acoustics and their applications.

  17. Interior acoustic cloak

    OpenAIRE

    Wael Akl; A. Baz

    2014-01-01

    Acoustic cloaks have traditionally been intended to externally surround critical objects to render these objects acoustically invisible. However, in this paper, the emphasis is placed on investigating the application of the acoustic cloaks to the interior walls of acoustic cavities in an attempt to minimize the noise levels inside these cavities. In this manner, the acoustic cloaks can serve as a viable and efficient alternative to the conventional passive noise attenuation treatments which a...

  18. Pluridirectional High-Energy Agile Scanning Electron Radiotherapy (PHASER): Extremely Rapid Treatment for Early Lung Cancer

    Science.gov (United States)

    2015-09-01

    esophagus , and anal cancer cases. We performed Monte Carlo (MC) dose calculations and we optimized the dose in a research version of RayStation... esophagus , and anal cancer cases. We 44 performed Monte Carlo (MC) dose calculations and we optimized the dose in a research version of...clinical cases were: acoustic neuroma, and liver, lung, esophagus and anal cancer 120 cases. Target sizes ranged from 1.2 cm3 to 990.4 cm3 (Table 1

  19. Acoustic energy harvesting based on a planar acoustic metamaterial

    Science.gov (United States)

    Qi, Shuibao; Oudich, Mourad; Li, Yong; Assouar, Badreddine

    2016-06-01

    We theoretically report on an innovative and practical acoustic energy harvester based on a defected acoustic metamaterial (AMM) with piezoelectric material. The idea is to create suitable resonant defects in an AMM to confine the strain energy originating from an acoustic incidence. This scavenged energy is converted into electrical energy by attaching a structured piezoelectric material into the defect area of the AMM. We show an acoustic energy harvester based on a meta-structure capable of producing electrical power from an acoustic pressure. Numerical simulations are provided to analyze and elucidate the principles and the performances of the proposed system. A maximum output voltage of 1.3 V and a power density of 0.54 μW/cm3 are obtained at a frequency of 2257.5 Hz. The proposed concept should have broad applications on energy harvesting as well as on low-frequency sound isolation, since this system acts as both acoustic insulator and energy harvester.

  20. Vestibular schwannoma with contralateral facial pain – case report

    Directory of Open Access Journals (Sweden)

    Ghodsi Mohammad

    2003-03-01

    Full Text Available Abstract Background Vestibular schwannoma (acoustic neuroma most commonly presents with ipsilateral disturbances of acoustic, vestibular, trigeminal and facial nerves. Presentation of vestibular schwannoma with contralateral facial pain is quite uncommon. Case presentation Among 156 cases of operated vestibular schwannoma, we found one case with unusual presentation of contralateral hemifacial pain. Conclusion The presentation of contralateral facial pain in the vestibular schwannoma is rare. It seems that displacement and distortion of the brainstem and compression of the contralateral trigeminal nerve in Meckel's cave by the large mass lesion may lead to this atypical presentation. The best practice in these patients is removal of the tumour, although persistent contralateral pain after operation has been reported.

  1. Panel acoustic contribution analysis.

    Science.gov (United States)

    Wu, Sean F; Natarajan, Logesh Kumar

    2013-02-01

    Formulations are derived to analyze the relative panel acoustic contributions of a vibrating structure. The essence of this analysis is to correlate the acoustic power flow from each panel to the radiated acoustic pressure at any field point. The acoustic power is obtained by integrating the normal component of the surface acoustic intensity, which is the product of the surface acoustic pressure and normal surface velocity reconstructed by using the Helmholtz equation least squares based nearfield acoustical holography, over each panel. The significance of this methodology is that it enables one to analyze and rank relative acoustic contributions of individual panels of a complex vibrating structure to acoustic radiation anywhere in the field based on a single set of the acoustic pressures measured in the near field. Moreover, this approach is valid for both interior and exterior regions. Examples of using this method to analyze and rank the relative acoustic contributions of a scaled vehicle cabin are demonstrated.

  2. Orthokeratinised odontogenic cyst mimicking periapical cyst

    OpenAIRE

    Rajalakshmi, R; Sreeja, C; Vijayalakshmi, D; Leelarani, V

    2013-01-01

    Orthokeratinised odontogenic cyst (OOC) denotes the odontogenic cyst that microscopically has an orthokeratinised epithelial lining. OOC is characterised by a less-aggressive behaviour and a low rate of recurrence. This report describes a case of OOC involving posterior part of the mandible that mimicked periapical cyst in a 14-year-old boy. The initial clinical diagnosis was given as periapical cyst based on the clinical and radiographical features. Enucleation of the cyst was performed and ...

  3. Ectopic decidual reaction mimicking inguinal lymphoma on ultrasound

    DEFF Research Database (Denmark)

    Lorentzen, C.; Prangsgaard, Tina; Lorentzen, Torben

    2014-01-01

    Ectopic decidual reaction has been described in various intraperitoneal locations. We present a case of unusual ectopic decidual reaction in the groin mimicking inguinal lymphoma on ultrasound in a pregnant woman. This case contributes evidence illustrating the variability of the clinical...... presentation of ectopic decidual reaction....

  4. Rare extraskeletal Ewing's sarcoma mimicking as adenocarcinoma of the sigmoid.

    Science.gov (United States)

    Mertens, Michelle; Haenen, Filip W N; Siozopoulou, Vasiliki; Van Cleemput, Marc

    2017-06-01

    Extraskeletal Ewing's sarcoma (EES) is a rare finding in comparison with Ewing's sarcoma of bone and usually manifests in young patients. However, even in older patients, one must consider the diagnosis. In this case, we describe a 52-year-old woman diagnosed with EES, mimicking as adenocarcinoma of the sigmoid. The tumor was not visualized by a multi-slice spiral computed tomography of the abdomen and pelvis with intravenous contrast, and eventually the diagnosis was made by positive immunohistochemical staining for CD99 and by molecular testing for EWSR1 translocation. This combination of the patient's age and the localization of the tumor mimicking an adenocarcinoma of the sigmoid has never been described before.

  5. Tension pneumocephalus mimicking septic shock: a case report.

    Science.gov (United States)

    Miranda, Caroline; Mahta, Ali; Wheeler, Lee Adam; Tsiouris, A John; Kamel, Hooman

    2018-02-01

    Tension pneumocephalus can lead to rapid neurologic deterioration. We report for the first time its association with aseptic systemic inflammatory response syndrome mimicking septic shock and the efficacy of prompt neurosurgical intervention and critical care support in treating this condition. A 64-year-old man underwent 2-stage olfactory groove meningioma resection. The patient developed altered mental status and gait instability on postoperative day 6. Imaging showed significant pneumocephalus. The patient subsequently developed worsening mental status, respiratory failure, and profound shock requiring multiple vasopressors. Bedside needle decompression, identification and repair of the cranial fossa defect, and critical care support led to improved mental status and reversal of shock and multiorgan dysfunction. Thorough evaluation revealed no evidence of an underlying infection. In this case, tension pneumocephalus incited an aseptic systemic inflammatory response syndrome mimicking septic shock. Prompt neurosurgical correction of pneumocephalus and critical care support not only improved neurologic status, but also reversed shock. Such a complication indicates the importance of close monitoring of patients with progressive pneumocephalus.

  6. Springer Handbook of Acoustics

    CERN Document Server

    Rossing, Thomas D

    2007-01-01

    Acoustics, the science of sound, has developed into a broad interdisciplinary field encompassing the academic disciplines of physics, engineering, psychology, speech, audiology, music, architecture, physiology, neuroscience, and others. The Springer Handbook of Acoustics is an unparalleled modern handbook reflecting this richly interdisciplinary nature edited by one of the acknowledged masters in the field, Thomas Rossing. Researchers and students benefit from the comprehensive contents spanning: animal acoustics including infrasound and ultrasound, environmental noise control, music and human speech and singing, physiological and psychological acoustics, architectural acoustics, physical and engineering acoustics, signal processing, medical acoustics, and ocean acoustics. This handbook reviews the most important areas of acoustics, with emphasis on current research. The authors of the various chapters are all experts in their fields. Each chapter is richly illustrated with figures and tables. The latest rese...

  7. Evaluation The Result Of Treating 1200 Patients Brain Tumor And Some Intracranial Diseases By Rotating GAMMA Knife (RGK) At The Nuclear Medicine And Oncology Center, Bach Mai Hospital

    International Nuclear Information System (INIS)

    Mai Trong Khoa; Nguyen Quang Hung; Tran Dinh Ha

    2011-01-01

    The paper is evaluating results of treating brain tumor and some intracranial diseases by rotating gamma knife (RGK) at The Nuclear Medicine and Oncology Center, Bach Mai Hospital, from July 2007 to August 2010, for 1200 patients treated with RGK. In 1200 patients - average age: 42.6 years old, Male/Female ratio:1/1.08 - pituitary tumors accounted for 19.8%, meningioma 18.3%, arteriovenous malformations (AVM) (16.7%), acoustic neuroma (8.7%), brain metastases (7.5%), craniopharyngeal tumor (5.0%), pineal tumor (3.5%), cavernoma (6%), astrocytoma (5.2%), meduloblastoma (2.9%), ependymoma (2.6%), others (3.8%). Average target volume: minimum 0.6cm 3 , maximum 27.6cm 3 , median 6.2 ± 4.6 cm 3 . Average radiosurgery dose changed depend on nature of the tumor: pituitary tumor (12.4 Gy), meningioma (18.8 Gy), AVM (18 Gy), acoustic neuroma (14.6 Gy), brain metastases (18.2 Gy), craniopharyngeal tumor (12.8 Gy), pineal tumor (16.3 Gy), cavernoma (17.5 Gy), astrocytoma (14.6 Gy), medulloblastoma (16.1 Gy), ependymoma (16.3 Gy), others (15 Gy). Conclusions: Almost case have improved clinical symptoms significantly: 80.2% after 1 month (complete response 20.2%), 100% at 36th month (complete response: 94%). Size of the tumor were reduced remarkably. Treatment were safe, no death or severe complications were observed within and after radiosurgery. (author)

  8. Electrocardiogram artifact caused by rigors mimicking narrow complex tachycardia: a case report.

    Science.gov (United States)

    Matthias, Anne Thushara; Indrakumar, Jegarajah

    2014-02-04

    The electrocardiogram (ECG) is useful in the diagnosis of cardiac and non-cardiac conditions. Rigors due to shivering can cause electrocardiogram artifacts mimicking various cardiac rhythm abnormalities. We describe an 80-year-old Sri Lankan man with an abnormal electrocardiogram mimicking narrow complex tachycardia during the immediate post-operative period. Electrocardiogram changes caused by muscle tremor during rigors could mimic a narrow complex tachycardia. Identification of muscle tremor as a cause of electrocardiogram artifact can avoid unnecessary pharmacological and non-pharmacological intervention to prevent arrhythmias.

  9. Intra-abdominal gout mimicking pelvic abscess

    International Nuclear Information System (INIS)

    Chen, Chia-Hui; Chen, Clement Kuen-Huang; Yeh, Lee-Ren; Pan, Huay-Ban; Yang, Chien-Fang

    2005-01-01

    Gout is the most common crystal-induced arthritis. Gouty tophi typically deposit in the extremities, especially toes and fingers. We present an unusual case of intrapelvic tophaceous gout in a patient suffering from chronic gouty arthritis. CT and MRI of the abdomen and pelvic cavity disclosed calcified gouty tophi around both hips, and a cystic lesion with peripheral enhancement in the pelvic cavity along the course of the iliopsoas muscle. The intra-abdominal tophus mimicked pelvic abscess. (orig.)

  10. Intra-abdominal gout mimicking pelvic abscess

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chia-Hui; Chen, Clement Kuen-Huang [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (Taiwan); National Yang-Ming University, School of Medicine, Taipei (Taiwan); Yeh, Lee-Ren; Pan, Huay-Ban; Yang, Chien-Fang [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (Taiwan)

    2005-04-01

    Gout is the most common crystal-induced arthritis. Gouty tophi typically deposit in the extremities, especially toes and fingers. We present an unusual case of intrapelvic tophaceous gout in a patient suffering from chronic gouty arthritis. CT and MRI of the abdomen and pelvic cavity disclosed calcified gouty tophi around both hips, and a cystic lesion with peripheral enhancement in the pelvic cavity along the course of the iliopsoas muscle. The intra-abdominal tophus mimicked pelvic abscess. (orig.)

  11. Nucleus-staining with biomolecule-mimicking nitrogen-doped carbon dots prepared by a fast neutralization heat strategy.

    Science.gov (United States)

    Kang, Yan-Fei; Fang, Yang-Wu; Li, Yu-Hao; Li, Wen; Yin, Xue-Bo

    2015-12-11

    Biomolecule-mimicking nitrogen-doped carbon dots (N-Cdots) were synthesized from dopamine by a neutralization heat strategy. Fluorescence imaging of various cells validated their nucleus-staining efficiency. The dopamine-mimicking N-Cdots "trick" nuclear membranes to achieve nuclear localization and imaging.

  12. Development of ion-acoustic double layers through ion-acoustic fluctuations

    International Nuclear Information System (INIS)

    Sekar, A.N.; Saxena, Y.C.

    1985-01-01

    Experimental results on the formation of ion acoustic double layers resembling asymmetric ion-holes are presented. In a double plasma device, modified suitably to inject electron beam into the target plasma, modulation of the beam through step potential leads to excitation of ion-acoustic fluctuation. The ion-acoustic fluctuation, growing away from the grids separating source and target plasmas, developed into weak asymmetric ion-acoustic double layer. The observations are in qualitative agreement with theoretical models and computer simulations. (author)

  13. Acoustic tweezers via sub-time-of-flight regime surface acoustic waves.

    Science.gov (United States)

    Collins, David J; Devendran, Citsabehsan; Ma, Zhichao; Ng, Jia Wei; Neild, Adrian; Ai, Ye

    2016-07-01

    Micrometer-scale acoustic waves are highly useful for refined optomechanical and acoustofluidic manipulation, where these fields are spatially localized along the transducer aperture but not along the acoustic propagation direction. In the case of acoustic tweezers, such a conventional acoustic standing wave results in particle and cell patterning across the entire width of a microfluidic channel, preventing selective trapping. We demonstrate the use of nanosecond-scale pulsed surface acoustic waves (SAWs) with a pulse period that is less than the time of flight between opposing transducers to generate localized time-averaged patterning regions while using conventional electrode structures. These nodal positions can be readily and arbitrarily positioned in two dimensions and within the patterning region itself through the imposition of pulse delays, frequency modulation, and phase shifts. This straightforward concept adds new spatial dimensions to which acoustic fields can be localized in SAW applications in a manner analogous to optical tweezers, including spatially selective acoustic tweezers and optical waveguides.

  14. Imaging findings of mimickers of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Tae Kyoung Kim

    2015-12-01

    Full Text Available Radiological imaging plays a crucial role in the diagnosis of hepatocellular carcinoma (HCC as the noninvasive diagnosis of HCC in high-risk patients by typical imaging findings alone is widely adopted in major practice guidelines for HCC. While imaging techniques have markedly improved in detecting small liver lesions, they often detect incidental benign liver lesions and non-hepatocellular malignancy that can be misdiagnosed as HCC. The most common mimicker of HCC in cirrhotic liver is nontumorous arterioportal shunts that are seen as focal hypervascular liver lesions on dynamic contrast-enhanced cross-sectional imaging. Rapidly enhancing hemangiomas can be easily misdiagnosed as HCC especially on MR imaging with liver-specific contrast agent. Focal inflammatory liver lesions mimic HCC by demonstrating arterial-phase hypervascularity and subsequent washout on dynamic contrast-enhanced imaging. It is important to recognize the suggestive imaging findings for intrahepatic cholangiocarcinoma (CC as the management of CC is largely different from that of HCC. There are other benign mimickers of HCC such as angiomyolipomas and focal nodular hyperplasia-like nodules. Recognition of their typical imaging findings can reduce false-positive HCC diagnosis.

  15. Osteoid osteoma and osteoid osteoma-mimicking lesions: biopsy findings, distinctive MDCT features and treatment by radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Becce, Fabio [Centre Hospitalier Universitaire Vaudois, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Universite Paris Descartes, Department of Radiology B, Hopital Cochin, AP-HP, Paris (France); Theumann, Nicolas [Centre Hospitalier Universitaire Vaudois, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Rochette, Antoine; Campagna, Raphael; Drape, Jean-Luc; Feydy, Antoine [Universite Paris Descartes, Department of Radiology B, Hopital Cochin, AP-HP, Paris (France); Larousserie, Frederique [Universite Paris Descartes, Department of Anatomic Pathology, Hopital Cochin, AP-HP, Paris (France); Cherix, Stephane; Mouhsine, Elyazid [Centre Hospitalier Universitaire Vaudois, Department of Orthopaedic and Traumatologic Surgery, Lausanne (Switzerland); Guillou, Louis [University Institute of Pathology, Centre Hospitalier Universitaire Vaudois, Lausanne (Switzerland); Anract, Philippe [Universite Paris Descartes, Department of Orthopaedic Surgery, Hopital Cochin, AP-HP, Paris (France)

    2010-10-15

    To report the biopsy findings of osteoid osteoma (OO) and OO-mimicking lesions, assess their distinctive multidetector computed tomography (MDCT) features and evaluate treatment by radiofrequency ablation (RFA). In this multicentric retrospective study, 80 patients (54 male, 26 female, mean age 24.1 years, range 5-48) with presumed (clinical and MDCT features) OO were treated by percutaneous RFA between May 2002 and June 2009. Per-procedural biopsies were always performed. The following MDCT features were assessed: skeletal distribution and location within the bone, size, central calcification, surrounding osteosclerosis and periosteal reaction. Clinical success of RFA was evaluated. Histopathological diagnoses were: 54 inconclusive biopsies, 16 OO, 10 OO-mimicking lesions (5 chronic osteomyelitis, 3 chondroblastoma, 1 eosinophilic granuloma, 1 fibrous dysplasia). OO-mimicking lesions were significantly greater in size (p = 0.001) and presented non-significant trends towards medullary location (p = 0.246), moderate surrounding osteosclerosis (p = 0.189) and less periosteal reaction (p = 0.197), compared with OO. Primary success for ablation of OO-mimicking lesions was 100% at 1 month, 85.7% at 6 and 12 months, and 66.7% at 24 months. Secondary success was 100%. Larger size, medullary location, less surrounding osteosclerosis and periosteal reaction on MDCT may help differentiate OO-mimicking lesions from OO. OO-mimicking lesions are safely and successfully treated by RFA. (orig.)

  16. Osteoid osteoma and osteoid osteoma-mimicking lesions: biopsy findings, distinctive MDCT features and treatment by radiofrequency ablation

    International Nuclear Information System (INIS)

    Becce, Fabio; Theumann, Nicolas; Rochette, Antoine; Campagna, Raphael; Drape, Jean-Luc; Feydy, Antoine; Larousserie, Frederique; Cherix, Stephane; Mouhsine, Elyazid; Guillou, Louis; Anract, Philippe

    2010-01-01

    To report the biopsy findings of osteoid osteoma (OO) and OO-mimicking lesions, assess their distinctive multidetector computed tomography (MDCT) features and evaluate treatment by radiofrequency ablation (RFA). In this multicentric retrospective study, 80 patients (54 male, 26 female, mean age 24.1 years, range 5-48) with presumed (clinical and MDCT features) OO were treated by percutaneous RFA between May 2002 and June 2009. Per-procedural biopsies were always performed. The following MDCT features were assessed: skeletal distribution and location within the bone, size, central calcification, surrounding osteosclerosis and periosteal reaction. Clinical success of RFA was evaluated. Histopathological diagnoses were: 54 inconclusive biopsies, 16 OO, 10 OO-mimicking lesions (5 chronic osteomyelitis, 3 chondroblastoma, 1 eosinophilic granuloma, 1 fibrous dysplasia). OO-mimicking lesions were significantly greater in size (p = 0.001) and presented non-significant trends towards medullary location (p = 0.246), moderate surrounding osteosclerosis (p = 0.189) and less periosteal reaction (p = 0.197), compared with OO. Primary success for ablation of OO-mimicking lesions was 100% at 1 month, 85.7% at 6 and 12 months, and 66.7% at 24 months. Secondary success was 100%. Larger size, medullary location, less surrounding osteosclerosis and periosteal reaction on MDCT may help differentiate OO-mimicking lesions from OO. OO-mimicking lesions are safely and successfully treated by RFA. (orig.)

  17. Peroxidase-Mimicking Nanozyme with Enhanced Activity and High Stability Based on Metal-Support Interactions.

    Science.gov (United States)

    Li, Zhihao; Yang, Xiangdong; Yang, Yanbing; Tan, Yaning; He, Yue; Liu, Meng; Liu, Xinwen; Yuan, Quan

    2018-01-09

    Peroxidase-mimicking nanozymes offer unique advantages in terms of high stability and low cost over natural peroxidase for applications in bioanalysis, biomedicine, and the treatment of pollution. However, the design of high-efficiency peroxidase-mimicking nanozymes remains a great challenge. In this study, we adopted a structural-design approach through hybridization of cube-CeO 2 and Pt nanoparticles to create a new peroxidase-mimicking nanozyme with high efficiency and excellent stability. Relative to pure cube-CeO 2 and Pt nanoparticles, the as-hybridized Pt/cube-CeO 2 nanocomposites display much improved activities because of the strong metal-support interaction. Meanwhile, the nanocomposites also maintain high catalytic activity after long-term storage and multiple recycling. Based on their excellent properties, Pt/cube-CeO 2 nanocomposites were used to construct high-performance colorimetric biosensors for the sensitive detection of metabolites, including H 2 O 2 and glucose. Our findings highlight opportunities for the development of high-efficiency peroxidase-mimicking nanozymes with potential applications such as diagnostics, biomedicine, and the treatment of pollution. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Mycobacterium intracellulare Infection Mimicking Progression of Scleroderma

    DEFF Research Database (Denmark)

    Krabbe, Simon; Engelhart, Merete; Thybo, Sören

    2017-01-01

    This case report describes a patient with scleroderma who developed Mycobacterium intracellulare infection, which for more than a year mimicked worsening of her connective tissue disorder. The patient was diagnosed with scleroderma based on puffy fingers that developed into sclerodactyly, abnormal......, unfortunately with significant scarring. Immunodeficiency testing was unremarkable. In summary, an infection with Mycobacterium intracellulare was mistaken for an unusually severe progression of scleroderma....

  19. Acoustic textiles

    CERN Document Server

    Nayak, Rajkishore

    2016-01-01

    This book highlights the manufacturing and applications of acoustic textiles in various industries. It also includes examples from different industries in which acoustic textiles can be used to absorb noise and help reduce the impact of noise at the workplace. Given the importance of noise reduction in the working environment in several industries, the book offers a valuable guide for companies, educators and researchers involved with acoustic materials.

  20. Architectural acoustics

    National Research Council Canada - National Science Library

    Long, Marshall

    2014-01-01

    .... Beginning with a brief history, it reviews the fundamentals of acoustics, human perception and reaction to sound, acoustic noise measurements, noise metrics, and environmental noise characterization...

  1. Supersonic acoustic intensity with statistically optimized near-field acoustic holography

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren; Jacobsen, Finn

    2011-01-01

    The concept of supersonic acoustic intensity was introduced some years ago for estimating the fraction of the flow of energy radiated by a source that propagates to the far field. It differs from the usual (active) intensity by excluding the near-field energy resulting from evanescent waves...... to the information provided by the near-field acoustic holography technique. This study proposes a version of the supersonic acoustic intensity applied to statistically optimized near-field acoustic holography (SONAH). The theory, numerical results and an experimental study are presented. The possibility of using...

  2. A multimodal instrument for real-time in situ study of ultrasound and cavitation mediated drug delivery.

    Science.gov (United States)

    Bian, Shuning; Seth, Anjali; Daly, Dan; Carlisle, Robert; Stride, Eleanor

    2017-03-01

    The development of a multimodal instrument capable of real-time in situ measurements of cavitation activity and effect in tissue mimicking phantoms during ultrasound and cavitation mediated drug delivery experiments is described here. The instrument features an acoustic arm that can expose phantoms to high-intensity focused-ultrasound while measuring cavitation activity and an optical arm that monitors cavitation effect using confocal microscopy. This combination of modalities allows real-time in situ characterisation of drug delivery in tissue and tissue mimicking phantoms during ultrasound and cavitation mediated drug delivery experiments. A representative result, obtained with a tissue mimicking phantom and acoustically activated droplets, is presented here as a demonstration of the instrument's capabilities and potential applications.

  3. Effects of mimicking: Acting prosocially by being emotionally moved

    NARCIS (Netherlands)

    Stel, M.; Baaren, R.B. van; Vonk, R.

    2008-01-01

    Mimicry is functional for empathy and bonding purposes. Studies on the consequences of mimicry at a behavioral level demonstrated that mimicry increases prosocial behavior. However, these previous studies focused on the mimickee. In the present paper, we investigated whether mimickers also become

  4. Endometriosis of the mesoappendix mimicking appendicitis: A case report

    Directory of Open Access Journals (Sweden)

    Suman Mewa Kinoo

    2016-09-01

    Full Text Available Although appendicitis is largely a clinical diagnosis, on occasions diagnostic modalities may be needed to aid with the diagnosis. Despite the use of adjuncts and exploratory surgery, the diagnosis may not be clear until a histological diagnosis is achieved. Endometriosis of the appendix mimicking appendicitis is one of these diagnoses described in several case reports. Endometriosis of the meso-appendix has been described in association with intussusception of the appendix in several case reports. However, to our knowledge, endometriosis of the meso-appendix mimicking appendicitis has not been reported to date. We present the case of a 33-year-old woman with classic clinical signs and symptoms of appendicitis endorsed on computed tomography imaging. The patient underwent a laparoscopic appendicectomy with the postoperative histology demonstrating a normal appendix with endometriosis of the meso-appendix.

  5. Acoustic Metamaterials in Aeronautics

    Directory of Open Access Journals (Sweden)

    Giorgio Palma

    2018-06-01

    Full Text Available Metamaterials, man-made composites that are scaled smaller than the wavelength, have demonstrated a huge potential for application in acoustics, allowing the production of sub-wavelength acoustic absorbers, acoustic invisibility, perfect acoustic mirrors and acoustic lenses for hyper focusing, and acoustic illusions and enabling new degrees of freedom in the control of the acoustic field. The zero, or even negative, refractive sound index of metamaterials offers possibilities for the control of acoustic patterns and sound at sub-wavelength scales. Despite the tremendous growth in research on acoustic metamaterials during the last decade, the potential of metamaterial-based technologies in aeronautics has still not been fully explored, and its utilization is still in its infancy. Thus, the principal concepts mentioned above could very well provide a means to develop devices that allow the mitigation of the impact of civil aviation noise on the community. This paper gives a review of the most relevant works on acoustic metamaterials, analyzing them for their potential applicability in aeronautics, and, in this process, identifying possible implementation areas and interesting metabehaviors. It also identifies some technical challenges and possible future directions for research with the goal of unveiling the potential of metamaterials technology in aeronautics.

  6. Tension pneumocephalus mimicking septic shock: a case report

    Directory of Open Access Journals (Sweden)

    Caroline Miranda, MD

    2018-02-01

    Full Text Available Tension pneumocephalus can lead to rapid neurologic deterioration. We report for the first time its association with aseptic systemic inflammatory response syndrome mimicking septic shock and the efficacy of prompt neurosurgical intervention and critical care support in treating this condition. A 64-year-old man underwent 2-stage olfactory groove meningioma resection. The patient developed altered mental status and gait instability on postoperative day 6. Imaging showed significant pneumocephalus. The patient subsequently developed worsening mental status, respiratory failure, and profound shock requiring multiple vasopressors. Bedside needle decompression, identification and repair of the cranial fossa defect, and critical care support led to improved mental status and reversal of shock and multiorgan dysfunction. Thorough evaluation revealed no evidence of an underlying infection. In this case, tension pneumocephalus incited an aseptic systemic inflammatory response syndrome mimicking septic shock. Prompt neurosurgical correction of pneumocephalus and critical care support not only improved neurologic status, but also reversed shock. Such a complication indicates the importance of close monitoring of patients with progressive pneumocephalus.

  7. Simultaneous observation of cavitation bubbles generated in biological tissue by high-speed optical and acoustic imaging methods

    Science.gov (United States)

    Suzuki, Kai; Iwasaki, Ryosuke; Takagi, Ryo; Yoshizawa, Shin; Umemura, Shin-ichiro

    2017-07-01

    Acoustic cavitation bubbles are useful for enhancing the heating effect in high-intensity focused ultrasound (HIFU) treatment. Many studies were conducted to investigate the behavior of such bubbles in tissue-mimicking materials, such as a transparent gel phantom; however, the detailed behavior in tissue was still unclear owing to the difficulty in optical observation. In this study, a new biological phantom was developed to observe cavitation bubbles generated in an optically shallow area of tissue. Two imaging methods, high-speed photography using light scattering and high-speed ultrasonic imaging, were used for detecting the behavior of the bubbles simultaneously. The results agreed well with each other for the area of bubble formation and the temporal change in the region of bubbles, suggesting that both methods are useful for visualizing the bubbles.

  8. Intracranial capillary hemangioma mimicking a dissociative disorder

    Directory of Open Access Journals (Sweden)

    Alexander Lacasse

    2012-01-01

    Full Text Available Capillary hemangiomas, hamartomatous proliferation of vascular endothelial cells, are rare in the central nervous system (CNS. Intracranial capillary hemangiomas presenting with reversible behavioral abnormalities and focal neurological deficits have rarely been reported. We report a case of CNS capillary hemangioma presenting with transient focal neurological deficits and behavioral abnormalities mimicking Ganser’s syndrome. Patient underwent total excision of the vascular malformation, resulting in complete resolution of his symptoms.

  9. Calibration of acoustic emission transducers

    International Nuclear Information System (INIS)

    Leschek, W.C.

    1976-01-01

    A method is described for calibrating an acoustic emission transducer to be used in a pre-set frequency range. The absolute reception sensitivity of a reference transducer is determined at frequencies selected within the frequency range. The reference transducer and the acoustic emission transducer are put into acoustic communication with the surface of a limited acoustic medium representing an equivalent acoustic load appreciably identical to that of the medium in which the use of the acoustic emission transducer is intended. A blank random acoustic noise is emitted in the acoustic medium in order to establish a diffuse and reverberating sound field, after which the output responses of the reference transducer and of the acoustic emission transducer are obtained with respect to the diffuse and reverberating field, for selected frequencies. The output response of the acoustic emission transducer is compared with that of the reference transducer for the selected frequencies, so as to determine the reception sensitivity of the acoustic emission transducer [fr

  10. Acoustical and optical radiation pressure and the development of single beam acoustical tweezers

    International Nuclear Information System (INIS)

    Thomas, Jean-Louis; Marchiano, Régis; Baresch, Diego

    2017-01-01

    Studies on radiation pressure in acoustics and optics have enriched one another and have a long common history. Acoustic radiation pressure is used for metrology, levitation, particle trapping and actuation. However, the dexterity and selectivity of single-beam optical tweezers are still to be matched with acoustical devices. Optical tweezers can trap, move and position micron size particles, biological samples or even atoms with subnanometer accuracy in three dimensions. One limitation of optical tweezers is the weak force that can be applied without thermal damage due to optical absorption. Acoustical tweezers overcome this limitation since the radiation pressure scales as the field intensity divided by the speed of propagation of the wave. However, the feasibility of single beam acoustical tweezers was demonstrated only recently. In this paper, we propose a historical review of the strong similarities but also the specificities of acoustical and optical radiation pressures, from the expression of the force to the development of single-beam acoustical tweezers. - Highlights: • Studies on radiation pressure in acoustics and optics have enriched one another and have a long common history. • Acoustic radiation pressure is used for metrology, levitation, particle trapping and actuation. • However, the dexterity and selectivity of single-beam optical tweezers are still to be matched with acoustical devices. • Optical tweezers can trap, move and positioned micron size particles with subnanometer accuracy in three dimensions. • One limitation of optical tweezers is the weak force that can be applied without thermal damage due to optical absorption. • Acoustical tweezers overcome this limitation since the force scales as the field intensity divided by its propagation speed. • However, the feasibility of single beam acoustical tweezers was demonstrated only recently. • We propose a review of the strong similarities but also the specificities of acoustical

  11. Brown tumor mimicking maxillary sinus mucocele as the first manifestation of primary hyperparathyroidism

    DEFF Research Database (Denmark)

    Guldfred, Liviu-Adelin; Daugaard, Søren; von Buchwald, Christian

    2012-01-01

    We describe the first case of brown tumor mimicking a maxillary sinus mucocele as the first manifestation of the patient's primary hyperparathyroidism. A 34-year old woman presented with a 14 days history of elevation of the right orbit, retrobulbar pain and cheek anesthesia. The CT and MR evalua...... either giant cell granuloma or brown tumor. The finding of hyperparathyroidism confirmed the diagnosis of brown tumor. To our knowledge, this is the first report of cystic brown tumor mimicking a mucocele of the maxillary sinus....

  12. Clinical and Histologic Mimickers of Celiac Disease.

    Science.gov (United States)

    Kamboj, Amrit K; Oxentenko, Amy S

    2017-08-17

    Celiac disease is an autoimmune disorder of the small bowel, classically associated with diarrhea, abdominal pain, and malabsorption. The diagnosis of celiac disease is made when there are compatible clinical features, supportive serologic markers, representative histology from the small bowel, and response to a gluten-free diet. Histologic findings associated with celiac disease include intraepithelial lymphocytosis, crypt hyperplasia, villous atrophy, and a chronic inflammatory cell infiltrate in the lamina propria. It is important to recognize and diagnose celiac disease, as strict adherence to a gluten-free diet can lead to resolution of clinical and histologic manifestations of the disease. However, many other entities can present with clinical and/or histologic features of celiac disease. In this review article, we highlight key clinical and histologic mimickers of celiac disease. The evaluation of a patient with serologically negative enteropathy necessitates a carefully elicited history and detailed review by a pathologist. Medications can mimic celiac disease and should be considered in all patients with a serologically negative enteropathy. Many mimickers of celiac disease have clues to the underlying diagnosis, and many have a targeted therapy. It is necessary to provide patients with a correct diagnosis rather than subject them to a lifetime of an unnecessary gluten-free diet.

  13. Radiation acoustics and its applications

    International Nuclear Information System (INIS)

    Lyamshev, L.M.

    1992-01-01

    Radiation acoustics is a new branch of acoustics, developing on the boundary of acoustics, nuclear physics, elementary particles and high-energy physics. Its fundamentals are laying in the research of acoustical effects due to the interaction of penetrating radiation with matter. The study of radiation-acoustical effects leads to the new opportunities in the penetration radiation research (acoustical detection, radiation-acoustical dosimetry), study of the physical parameters of matter, in a solution of some applied problems of nondestructive testing, and also for the radiation-acoustical influence on physical and chemical structure of the matter. Results of theoretical and experimental investigations are given. Different mechanisms of the sound generation by penetrating radiation of liquids and solids are considered. Some applications - the radiation acoustical microscopy and visualisation, the acoustical detection of high energy X-ray particles and possibility of using of high energy neutrino beams in geoacoustics - are discussed

  14. Parametric Room Acoustic Workflows

    DEFF Research Database (Denmark)

    Parigi, Dario; Svidt, Kjeld; Molin, Erik

    2017-01-01

    The paper investigates and assesses different room acoustics software and the opportunities they offer to engage in parametric acoustics workflow and to influence architectural designs. The first step consists in the testing and benchmarking of different tools on the basis of accuracy, speed...... and interoperability with Grasshopper 3d. The focus will be placed to the benchmarking of three different acoustic analysis tools based on raytracing. To compare the accuracy and speed of the acoustic evaluation across different tools, a homogeneous set of acoustic parameters is chosen. The room acoustics parameters...... included in the set are reverberation time (EDT, RT30), clarity (C50), loudness (G), and definition (D50). Scenarios are discussed for determining at different design stages the most suitable acoustic tool. Those scenarios are characterized, by the use of less accurate but fast evaluation tools to be used...

  15. Bio-Inspired PVDF-Based, Mouse Whisker Mimicking, Tactile Sensor

    Directory of Open Access Journals (Sweden)

    Mohsin Islam Tiwana

    2016-10-01

    Full Text Available The design and fabrication of a Polyvinylidene fluoride (PVDF based, mouse (or rodent whisker mimicking, tactile sensor is presented. Unlike previous designs reported in the literature, this sensor mimics the mouse whisker not only mechanically, but it also makes macro movements just like a real mouse whisker in a natural environment. We have developed a mathematical model and performed finite element analysis using COMSOL, in order to optimise the whisker to have the same natural frequency as that of a biological whisker. Similarly, we have developed a control system that enables the whisker mimicking sensor to vibrate at variable frequencies and conducted practical experiments to validate the response of the sensor. The natural frequency of the whisker can be designed anywhere between 35 and 110 Hz, the same as a biological whisker, by choosing different materials and physical dimensions. The control system of this sensor enables the whisker to vibrate between 5 and 236 Hz.

  16. High-Frequency Seafloor Acoustics

    CERN Document Server

    Jackson, Darrell R

    2007-01-01

    High-Frequency Seafloor Acoustics is the first book in a new series sponsored by the Office of Naval Research on the latest research in underwater acoustics. This exciting new title provides ready access to experimental data, theory, and models relevant to high-frequency seafloor acoustics and will be of interest to sonar engineers and researchers working in underwater acoustics. The physical characteristics of the seafloor affecting acoustic propagation and scattering are covered, including physical and geoacoustic properties and surface roughness. Current theories for acoustic propagation in sediments are presented along with corresponding models for reflection, scattering, and seafloor penetration. The main text is backed up by an extensive bibliography and technical appendices.

  17. Acoustic evaluation of wood quality in standing trees. Part I, Acoustic wave behavior

    Science.gov (United States)

    Xiping Wang; Robert J. Ross; Peter Carter

    2007-01-01

    Acoustic wave velocities in standing trees or live softwood species were measured by the time-of-flight (TOF) method. Tree velocities were compared with acoustic velocities measured in corresponding butt logs through a resonance acoustic method. The experimental data showed a skewed relationship between tree and log acoustic measurements. For most trees tested,...

  18. Subependymal Heterotopia Mimicking Mass in Conventional Magnetic Resonance Imaging: Demonstration With 3T Advanced Neuroimages.

    Science.gov (United States)

    Aktas, Filiz; Ogul, Hayri

    2017-10-01

    The authors reported a rare patient with large subependymal heterotopia mimicking cerebral neoplasia. A 22-year-old female was admitted with a history of right-sided paresthesia accompanied by progressive headache. Cerebral magnetic resonance (MR) imaging showed a large solid lesion in the left frontal lobe. Advanced MR images proved that the lesion was compatible with subependymal heterotopia. Large subependymal heterotopia may mimick cerebral neoplasia.

  19. Autoimmunity to Tropomyosin-Specific Peptides Induced by Mycobacterium leprae in Leprosy Patients: Identification of Mimicking Proteins.

    Science.gov (United States)

    Singh, Itu; Yadav, Asha Ram; Mohanty, Keshar Kunja; Katoch, Kiran; Sharma, Prashant; Pathak, Vinay Kumar; Bisht, Deepa; Gupta, Umesh D; Sengupta, Utpal

    2018-01-01

    It has been shown earlier that there is a rise in the levels of autoantibodies and T cell response to cytoskeletal proteins in leprosy. Our group recently demonstrated a rise in both T and B cell responses to keratin and myelin basic protein in all types of leprosy patients and their associations in type 1 reaction (T1R) group of leprosy. In this study, we investigated the association of levels of autoantibodies and lymphoproliferation against myosin in leprosy patients across the spectrum and tried to find out the mimicking proteins or epitopes between host protein and protein/s of Mycobacterium leprae . One hundred and sixty-nine leprosy patients and 55 healthy controls (HC) were enrolled in the present study. Levels of anti-myosin antibodies and T-cell responses against myosin were measured by ELISA and lymphoproliferation assay, respectively. Using 2-D gel electrophoresis, western blot and MALDI-TOF/TOF antibody-reactive spots were identified. Three-dimensional structure of mimicking proteins was modeled by online server. B cell epitopes of the proteins were predicted by BCPREDS server 1.0 followed by identification of mimicking epitopes. Mice of inbred BALB/c strain were hyperimmunized with M. leprae soluble antigen (MLSA) and splenocytes and lymph node cells of these animals were adoptively transferred to naïve mice. Highest level of anti-myosin antibodies was noted in sera of T1R leprosy patients. We observed significantly higher levels of lymphoproliferative response ( p  leprae . We found four mimicking epitopes between these sequences. These data suggest that these mimicking proteins tropomyosin and ATP-dependent Clp protease ATP-binding subunit of M. leprae or more precisely mimicking epitopes (four B cell epitopes) might be responsible for extensive tissue damage during type1 reaction in leprosy.

  20. Room Acoustics

    Science.gov (United States)

    Kuttruff, Heinrich; Mommertz, Eckard

    The traditional task of room acoustics is to create or formulate conditions which ensure the best possible propagation of sound in a room from a sound source to a listener. Thus, objects of room acoustics are in particular assembly halls of all kinds, such as auditoria and lecture halls, conference rooms, theaters, concert halls or churches. Already at this point, it has to be pointed out that these conditions essentially depend on the question if speech or music should be transmitted; in the first case, the criterion for transmission quality is good speech intelligibility, in the other case, however, the success of room-acoustical efforts depends on other factors that cannot be quantified that easily, not least it also depends on the hearing habits of the listeners. In any case, absolutely "good acoustics" of a room do not exist.

  1. Acoustic scaling: A re-evaluation of the acoustic model of Manchester Studio 7

    Science.gov (United States)

    Walker, R.

    1984-12-01

    The reasons for the reconstruction and re-evaluation of the acoustic scale mode of a large music studio are discussed. The design and construction of the model using mechanical and structural considerations rather than purely acoustic absorption criteria is described and the results obtained are given. The results confirm that structural elements within the studio gave rise to unexpected and unwanted low-frequency acoustic absorption. The results also show that at least for the relatively well understood mechanisms of sound energy absorption physical modelling of the structural and internal components gives an acoustically accurate scale model, within the usual tolerances of acoustic design. The poor reliability of measurements of acoustic absorption coefficients, is well illustrated. The conclusion is reached that such acoustic scale modelling is a valid and, for large scale projects, financially justifiable technique for predicting fundamental acoustic effects. It is not appropriate for the prediction of fine details because such small details are unlikely to be reproduced exactly at a different size without extensive measurements of the material's performance at both scales.

  2. Friedreich's ataxia mimicking hereditary motor and sensory neuropathy.

    Science.gov (United States)

    Panas, Marios; Kalfakis, Nikolaos; Karadima, Georgia; Davaki, Panagiota; Vassilopoulos, Demetris

    2002-11-01

    Four patients from three unrelated families, with clinical and electrophysiological findings compatible with the diagnosis of hereditary motor and sensory neuropathy, are presented. The molecular analysis showed that the affected individuals were homozygous for the mutation in the X25 gene, characteristic of Friedreich's ataxia. These patients seem to represent a form of Friedreich's ataxia mimicking Charcot-Marie-Tooth disease.

  3. CALCULATION OF ACOUSTIC EFFICIENCY OF PORTABLE ACOUSTIC SCREEN

    Directory of Open Access Journals (Sweden)

    Aleksandr Skvortsov

    2016-03-01

    Full Text Available The research of influence of life environment adverse factors on physical development and health of population is an actual problem of ecology. The aspects of the most actual problems of the modern world, namely environmental industrial noise pollution are considered in the article. Industrial facilities everywhere have noisy equipment. Noise is a significant factors of negative influenceon people and environment. Combined effects of noise and of other physical pollutions on people may cause amplification of their negative impact. If the noise pollution level from the object in a residential area exceeds the permissible levels (MPL, noise protection measures can be initiated. Today, the most common design decisions for noise protection are sound absorbing construction, noise screens and barriers, acousting housings, soundproff cabins. Many of them are popular, others are less known. The article deals with one of the most wide spread means of noise protection – a portable acoustic screen. The aim of the research is to determine the efficiency of portable acoustic screens. It is shown that the installation of such structures can reduce the average value of the sound level. The authors analyzed acoustic screens as device to reduce noise pollution. The authors offer a potable acoustic screen differing from the used easyness, mobility, minimum price and good sound protective properties. Effectiveness, a sound absorption coefficient and sound conductivity coefficient of a portable acoustic screen are evaluated. The descriptions of the algorithm calculations and the combination of technical solutions have practical originality. The results of the research demonstrate the advantages of the proposed solutions for reducing noise levels in the agro-industrial complex.

  4. Autoimmunity to Tropomyosin-Specific Peptides Induced by Mycobacterium leprae in Leprosy Patients: Identification of Mimicking Proteins

    Directory of Open Access Journals (Sweden)

    Itu Singh

    2018-04-01

    Full Text Available BackgroundIt has been shown earlier that there is a rise in the levels of autoantibodies and T cell response to cytoskeletal proteins in leprosy. Our group recently demonstrated a rise in both T and B cell responses to keratin and myelin basic protein in all types of leprosy patients and their associations in type 1 reaction (T1R group of leprosy.ObjectivesIn this study, we investigated the association of levels of autoantibodies and lymphoproliferation against myosin in leprosy patients across the spectrum and tried to find out the mimicking proteins or epitopes between host protein and protein/s of Mycobacterium leprae.MethodologyOne hundred and sixty-nine leprosy patients and 55 healthy controls (HC were enrolled in the present study. Levels of anti-myosin antibodies and T-cell responses against myosin were measured by ELISA and lymphoproliferation assay, respectively. Using 2-D gel electrophoresis, western blot and MALDI-TOF/TOF antibody-reactive spots were identified. Three-dimensional structure of mimicking proteins was modeled by online server. B cell epitopes of the proteins were predicted by BCPREDS server 1.0 followed by identification of mimicking epitopes. Mice of inbred BALB/c strain were hyperimmunized with M. leprae soluble antigen (MLSA and splenocytes and lymph node cells of these animals were adoptively transferred to naïve mice.ResultsHighest level of anti-myosin antibodies was noted in sera of T1R leprosy patients. We observed significantly higher levels of lymphoproliferative response (p < 0.05 with myosin in all types of leprosy patients compared to HC. Further, hyperimmunization of inbred BALB/c strain of female mice and rabbit with MLSA revealed that both hyperimmunized rabbit and mice evoked heightened levels of antibodies against myosin and this autoimmune response could be adoptively transferred from hyperimmunized to naïve mice. Tropomyosin was found to be mimicking with ATP-dependent Clp protease ATP

  5. Effects of subsampling of passive acoustic recordings on acoustic metrics.

    Science.gov (United States)

    Thomisch, Karolin; Boebel, Olaf; Zitterbart, Daniel P; Samaran, Flore; Van Parijs, Sofie; Van Opzeeland, Ilse

    2015-07-01

    Passive acoustic monitoring is an important tool in marine mammal studies. However, logistics and finances frequently constrain the number and servicing schedules of acoustic recorders, requiring a trade-off between deployment periods and sampling continuity, i.e., the implementation of a subsampling scheme. Optimizing such schemes to each project's specific research questions is desirable. This study investigates the impact of subsampling on the accuracy of two common metrics, acoustic presence and call rate, for different vocalization patterns (regimes) of baleen whales: (1) variable vocal activity, (2) vocalizations organized in song bouts, and (3) vocal activity with diel patterns. To this end, above metrics are compared for continuous and subsampled data subject to different sampling strategies, covering duty cycles between 50% and 2%. The results show that a reduction of the duty cycle impacts negatively on the accuracy of both acoustic presence and call rate estimates. For a given duty cycle, frequent short listening periods improve accuracy of daily acoustic presence estimates over few long listening periods. Overall, subsampling effects are most pronounced for low and/or temporally clustered vocal activity. These findings illustrate the importance of informed decisions when applying subsampling strategies to passive acoustic recordings or analyses for a given target species.

  6. 3D conformal MRI-controlled transurethral ultrasound prostate therapy: validation of numerical simulations and demonstration in tissue-mimicking gel phantoms.

    Science.gov (United States)

    Burtnyk, Mathieu; N'Djin, William Apoutou; Kobelevskiy, Ilya; Bronskill, Michael; Chopra, Rajiv

    2010-11-21

    MRI-controlled transurethral ultrasound therapy uses a linear array of transducer elements and active temperature feedback to create volumes of thermal coagulation shaped to predefined prostate geometries in 3D. The specific aims of this work were to demonstrate the accuracy and repeatability of producing large volumes of thermal coagulation (>10 cc) that conform to 3D human prostate shapes in a tissue-mimicking gel phantom, and to evaluate quantitatively the accuracy with which numerical simulations predict these 3D heating volumes under carefully controlled conditions. Eleven conformal 3D experiments were performed in a tissue-mimicking phantom within a 1.5T MR imager to obtain non-invasive temperature measurements during heating. Temperature feedback was used to control the rotation rate and ultrasound power of transurethral devices with up to five 3.5 × 5 mm active transducer elements. Heating patterns shaped to human prostate geometries were generated using devices operating at 4.7 or 8.0 MHz with surface acoustic intensities of up to 10 W cm(-2). Simulations were informed by transducer surface velocity measurements acquired with a scanning laser vibrometer enabling improved calculations of the acoustic pressure distribution in a gel phantom. Temperature dynamics were determined according to a FDTD solution to Pennes' BHTE. The 3D heating patterns produced in vitro were shaped very accurately to the prostate target volumes, within the spatial resolution of the MRI thermometry images. The volume of the treatment difference falling outside ± 1 mm of the target boundary was, on average, 0.21 cc or 1.5% of the prostate volume. The numerical simulations predicted the extent and shape of the coagulation boundary produced in gel to within (mean ± stdev [min, max]): 0.5 ± 0.4 [-1.0, 2.1] and -0.05 ± 0.4 [-1.2, 1.4] mm for the treatments at 4.7 and 8.0 MHz, respectively. The temperatures across all MRI thermometry images were predicted within -0.3 ± 1.6 °C and 0

  7. Acoustical and optical radiation pressure and the development of single beam acoustical tweezers

    Science.gov (United States)

    Thomas, Jean-Louis; Marchiano, Régis; Baresch, Diego

    2017-07-01

    Studies on radiation pressure in acoustics and optics have enriched one another and have a long common history. Acoustic radiation pressure is used for metrology, levitation, particle trapping and actuation. However, the dexterity and selectivity of single-beam optical tweezers are still to be matched with acoustical devices. Optical tweezers can trap, move and position micron size particles, biological samples or even atoms with subnanometer accuracy in three dimensions. One limitation of optical tweezers is the weak force that can be applied without thermal damage due to optical absorption. Acoustical tweezers overcome this limitation since the radiation pressure scales as the field intensity divided by the speed of propagation of the wave. However, the feasibility of single beam acoustical tweezers was demonstrated only recently. In this paper, we propose a historical review of the strong similarities but also the specificities of acoustical and optical radiation pressures, from the expression of the force to the development of single-beam acoustical tweezers.

  8. Computational Ocean Acoustics

    CERN Document Server

    Jensen, Finn B; Porter, Michael B; Schmidt, Henrik

    2011-01-01

    Since the mid-1970s, the computer has played an increasingly pivotal role in the field of ocean acoustics. Faster and less expensive than actual ocean experiments, and capable of accommodating the full complexity of the acoustic problem, numerical models are now standard research tools in ocean laboratories. The progress made in computational ocean acoustics over the last thirty years is summed up in this authoritative and innovatively illustrated new text. Written by some of the field's pioneers, all Fellows of the Acoustical Society of America, Computational Ocean Acoustics presents the latest numerical techniques for solving the wave equation in heterogeneous fluid–solid media. The authors discuss various computational schemes in detail, emphasizing the importance of theoretical foundations that lead directly to numerical implementations for real ocean environments. To further clarify the presentation, the fundamental propagation features of the techniques are illustrated in color. Computational Ocean A...

  9. Acoustic Test Results of Melamine Foam with Application to Payload Fairing Acoustic Attenuation Systems

    Science.gov (United States)

    Hughes, William O.; McNelis, Anne M.

    2014-01-01

    A spacecraft at launch is subjected to a harsh acoustic and vibration environment resulting from the passage of acoustic energy, created during the liftoff of a launch vehicle, through the vehicle's payload fairing. In order to ensure the mission success of the spacecraft it is often necessary to reduce the resulting internal acoustic sound pressure levels through the usage of acoustic attenuation systems. Melamine foam, lining the interior walls of the payload fairing, is often utilized as the main component of such a system. In order to better understand the acoustic properties of melamine foam, with the goal of developing improved acoustic attenuation systems, NASA has recently performed panel level testing on numerous configurations of melamine foam acoustic treatments at the Riverbank Acoustical Laboratory. Parameters assessed included the foam's thickness and density, as well as the effects of a top outer cover sheet material and mass barriers embedded within the foam. This testing followed the ASTM C423 standard for absorption and the ASTM E90 standard for transmission loss. The acoustic test data obtained and subsequent conclusions are the subjects of this paper.

  10. Density-near-zero using the acoustically induced transparency of a Fano acoustic resonator

    KAUST Repository

    Elayouch, A.

    2017-01-05

    We report experimental results of near-zero mass density involving an acoustic metamaterial supporting Fano resonance. For this, we designed and fabricated an acoustic resonator with two closely coupled modes and measured its transmission properties. Our study reveals that the phenomenon of acoustically induced transparency is accompanied by an effect of near-zero density. Indeed, the dynamic effective parameters obtained from experimental data show the presence of a frequency band where the effective mass density is close to zero, with high transmission levels reaching 0.7. Furthermore, we demonstrate that such effective parameters lead to wave guiding in a 90-degrees-bent channel. This kind of acoustic metamaterial can, therefore, give rise to acoustic functions like controlling the wavefront, which may lead to very promising applications in acoustic cloacking or imaging.

  11. Introducing passive acoustic filter in acoustic based condition monitoring: Motor bike piston-bore fault identification

    Science.gov (United States)

    Jena, D. P.; Panigrahi, S. N.

    2016-03-01

    Requirement of designing a sophisticated digital band-pass filter in acoustic based condition monitoring has been eliminated by introducing a passive acoustic filter in the present work. So far, no one has attempted to explore the possibility of implementing passive acoustic filters in acoustic based condition monitoring as a pre-conditioner. In order to enhance the acoustic based condition monitoring, a passive acoustic band-pass filter has been designed and deployed. Towards achieving an efficient band-pass acoustic filter, a generalized design methodology has been proposed to design and optimize the desired acoustic filter using multiple filter components in series. An appropriate objective function has been identified for genetic algorithm (GA) based optimization technique with multiple design constraints. In addition, the sturdiness of the proposed method has been demonstrated in designing a band-pass filter by using an n-branch Quincke tube, a high pass filter and multiple Helmholtz resonators. The performance of the designed acoustic band-pass filter has been shown by investigating the piston-bore defect of a motor-bike using engine noise signature. On the introducing a passive acoustic filter in acoustic based condition monitoring reveals the enhancement in machine learning based fault identification practice significantly. This is also a first attempt of its own kind.

  12. Acoustic comfort in eating establishments

    DEFF Research Database (Denmark)

    Svensson, David; Jeong, Cheol-Ho; Brunskog, Jonas

    2014-01-01

    The subjective concept of acoustic comfort in eating establishments has been investigated in this study. The goal was to develop a predictive model for the acoustic comfort, by means of simple objective parameters, while also examining which other subjective acoustic parameters could help explain...... the feeling of acoustic comfort. Through several layers of anal ysis, acoustic comfort was found to be rather complex, and could not be explained entirely by common subjective parameters such as annoyance, intelligibility or privacy. A predictive model for the mean acoustic comfort for an eating establishment...

  13. Springer handbook of acoustics

    CERN Document Server

    2014-01-01

    Acoustics, the science of sound, has developed into a broad interdisciplinary field encompassing the academic disciplines of physics, engineering, psychology, speech, audiology, music, architecture, physiology, neuroscience, and electronics. The Springer Handbook of Acoustics is also in his 2nd edition an unparalleled modern handbook reflecting this richly interdisciplinary nature edited by one of the acknowledged masters in the field, Thomas Rossing. Researchers and students benefit from the comprehensive contents. This new edition of the Handbook features over 11 revised and expanded chapters, new illustrations, and 2 new chapters covering microphone arrays  and acoustic emission.  Updated chapters contain the latest research and applications in, e.g. sound propagation in the atmosphere, nonlinear acoustics in fluids, building and concert hall acoustics, signal processing, psychoacoustics, computer music, animal bioacousics, sound intensity, modal acoustics as well as new chapters on microphone arrays an...

  14. Acoustical Imaging

    CERN Document Server

    Akiyama, Iwaki

    2009-01-01

    The 29th International Symposium on Acoustical Imaging was held in Shonan Village, Kanagawa, Japan, April 15-18, 2007. This interdisciplinary Symposium has been taking place every two years since 1968 and forms a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. In the course of the years the volumes in the Acoustical Imaging Series have developed and become well-known and appreciated reference works. Offering both a broad perspective on the state-of-the-art in the field as well as an in-depth look at its leading edge research, this Volume 29 in the Series contains again an excellent collection of seventy papers presented in nine major categories: Strain Imaging Biological and Medical Applications Acoustic Microscopy Non-Destructive Evaluation and Industrial Applications Components and Systems Geophysics and Underwater Imaging Physics and Mathematics Medical Image Analysis FDTD method and Other Numerical Simulations Audience Researcher...

  15. Battlefield acoustics

    CERN Document Server

    Damarla, Thyagaraju

    2015-01-01

    This book presents all aspects of situational awareness in a battlefield using acoustic signals. It starts by presenting the science behind understanding and interpretation of sound signals. The book then goes on to provide various signal processing techniques used in acoustics to find the direction of sound source, localize gunfire, track vehicles, and detect people. The necessary mathematical background and various classification and fusion techniques are presented. The book contains majority of the things one would need to process acoustic signals for all aspects of situational awareness in one location. The book also presents array theory, which is pivotal in finding the direction of arrival of acoustic signals. In addition, the book presents techniques to fuse the information from multiple homogeneous/heterogeneous sensors for better detection. MATLAB code is provided for majority of the real application, which is a valuable resource in not only understanding the theory but readers, can also use the code...

  16. Central skeletal sarcoidosis mimicking metastatic disease

    International Nuclear Information System (INIS)

    Talmi, Danit; Smith, Stacy; Mulligan, Michael E.

    2008-01-01

    Sarcoidosis is a systemic disease that histologically typically shows non-caseating granulomas. The most common radiologic finding is hilar and mediastinal adenopathy. Patients with widely disseminated disease may show involvement of the peripheral appendicular skeleton in 1-13% of such cases. A primary skeletal presentation without other manifestations typical of the disease is rare. We present a case of sarcoidosis in a middle-aged Caucasian man in whom the disease presented with widespread lytic lesions in the axial skeleton and long bones, mimicking metastatic disease. There was no involvement of the peripheral skeleton, skin or lungs. (orig.)

  17. Acoustic insulator for combined well equipment of acoustic and radioactivity logging

    International Nuclear Information System (INIS)

    Arkad'ev, E.A.; Gorbachev, Yu.I.; Dseban', I.P.; Yagodov, G.I.

    1977-01-01

    The design of an acoustic insulator for cobined well equipment of acoustic and radioactivity logaing made on the basis of studying the velocity of elastic waves propagation and attenuation in cable structures of various marks is described. It is shown that the cable probe of electric loggign equipment which is recommended as an acoustic insulator for combined well equipment has the necessary sound-insulating properties

  18. Evaluation of tomosynthesis elastography in a breast-mimicking phantom

    International Nuclear Information System (INIS)

    Engelken, Florian Jan; Sack, Ingolf; Klatt, Dieter; Fischer, Thomas; Fallenberg, Eva Maria; Bick, Ulrich; Diekmann, Felix

    2012-01-01

    Objective: To evaluate whether measurement of strain under static compression in tomosynthesis of a breast-mimicking phantom can be used to distinguish tumor-simulating lesions of different elasticities and to compare the results to values predicted by rheometric analysis as well as results of ultrasound elastography. Materials and methods: We prepared three soft breast-mimicking phantoms containing simulated tumors of different elasticities. The phantoms were imaged using a wide angle tomosynthesis system with increasing compression settings ranging from 0 N to 105 N in steps of 15 N. Strain of the inclusions was measured in two planes using a commercially available mammography workstation. The elasticity of the phantom matrix and inclusion material was determined by rheometric analysis. Ultrasound elastography of the inclusions was performed using two different ultrasound elastography algorithms. Results: Strain at maximal compression was 24.4%/24.5% in plane 1/plane 2, respectively, for the soft inclusion, 19.6%/16.9% for the intermediate inclusion, and 6.0%/10.2% for the firm inclusion. The strain ratios predicted by rheometrical testing were 0.41, 0.83 and 1.26 for the soft, intermediate, and firm inclusions, respectively. The strain ratios obtained for the soft, intermediate, and firm inclusions were 0.72 ± 0.13, 1.02 ± 0.21 and 2.67 ± 1.70, respectively for tomosynthesis elastography, 0.91, 1.64 and 2.07, respectively, for ultrasound tissue strain imaging, and 0.97, 2.06 and 2.37, respectively, for ultrasound real-time elastography. Conclusions: Differentiation of tumor-simulating inclusions by elasticity in a breast mimicking phantom may be possible by measuring strain in tomosynthesis. This method may be useful for assessing elasticity of breast lesions tomosynthesis of the breast

  19. Sociodemographic factors and vestibular schwannoma: a Danish nationwide cohort study

    DEFF Research Database (Denmark)

    Schüz, Joachim; Steding-Jessen, Marianne; Hansen, Søren

    2010-01-01

    Vestibular schwannoma (VS) (or acoustic neuroma) accounts for about 5%-6% of all intracranial tumors; little is known about the etiology. We investigated the association between various sociodemographic indicators and VS in a cohort of 3.26 million Danish residents, with 1087 cases identified in 35...... 308 974 person-years under risk, with data accrued from 1993 to 2006. Complete ascertainment of cases was ensured by using population-based and clinical cancer registries. Information on sociodemographic indicators was obtained on an annually updated individual level from Statistics Denmark. Log...

  20. Spinal MRI of vincristine neuropathy mimicking Guillain-Barre syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yun Woo; Yoon, Hye-Kyung; Cho, Jae Min [Department of Radiology, Samsung Medical Centre, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Kangnam-gu, Seoul 135-710 (Korea); Sung, Ki Woong [Department of Paediatrics, Samsung Medical Centre, Seoul 135-710 (Korea)

    2003-11-01

    A 4.3-year-old girl with acute leukaemia, who was being treated with chemotherapy (including vincristine), developed paraplegia. Spinal MRI showed diffusely enhancing nerve roots on contrast-enhanced images. Spinal fluid analysis showed a normal protein level. Vincristine neuropathy mimicking Guillain-Barre syndrome is thought to be the cause of the MRI abnormalities. (orig.)

  1. Spinal MRI of vincristine neuropathy mimicking Guillain-Barre syndrome

    International Nuclear Information System (INIS)

    Chang, Yun Woo; Yoon, Hye-Kyung; Cho, Jae Min; Sung, Ki Woong

    2003-01-01

    A 4.3-year-old girl with acute leukaemia, who was being treated with chemotherapy (including vincristine), developed paraplegia. Spinal MRI showed diffusely enhancing nerve roots on contrast-enhanced images. Spinal fluid analysis showed a normal protein level. Vincristine neuropathy mimicking Guillain-Barre syndrome is thought to be the cause of the MRI abnormalities. (orig.)

  2. Primary intraosseous squamous cell carcinoma mimicking periapical disease: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Joo; Oh, Song Hee; Kang, Ju Han; Choi, Hwa Young; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of); Yu, Jae June [Dept. of Oral and Maxillofacial Radiology, Kangdong Sacred Heart Hospital, Hallym Medical Center, Seoul (Korea, Republic of)

    2012-09-15

    Primary intraosseous squamous cell carcinoma (PIOSCC) is a rare carcinoma, which arises within the jaws without connection to the oral mucosa and presumably develops from a remnant of odontogenic epithelium. We present a case of solid type PIOSCC in a 52-year-old male patient complaining of dull pain on his left lower molar. In this case, early stage PIOSCC mimicking a periapical lesion might lead to a one-year delay in treatment due to the misdiagnosis of osteomyelitis after extraction of the third molar. The clinical, radiological, and histologic features are described. In this case, there was initial radiographic evidence for PIOSCC mimicking a periapical lesion. Incautious radiographic interpretation and treatment procedures had delayed the correct diagnosis and resulted in extensive bony destruction during the patient's disease progression.

  3. Acoustic and streaming velocity components in a resonant waveguide at high acoustic levels.

    Science.gov (United States)

    Daru, Virginie; Reyt, Ida; Bailliet, Hélène; Weisman, Catherine; Baltean-Carlès, Diana

    2017-01-01

    Rayleigh streaming is a steady flow generated by the interaction between an acoustic wave and a solid wall, generally assumed to be second order in a Mach number expansion. Acoustic streaming is well known in the case of a stationary plane wave at low amplitude: it has a half-wavelength spatial periodicity and the maximum axial streaming velocity is a quadratic function of the acoustic velocity amplitude at antinode. For higher acoustic levels, additional streaming cells have been observed. Results of laser Doppler velocimetry measurements are here compared to direct numerical simulations. The evolution of axial and radial velocity components for both acoustic and streaming velocities is studied from low to high acoustic amplitudes. Two streaming flow regimes are pointed out, the axial streaming dependency on acoustics going from quadratic to linear. The evolution of streaming flow is different for outer cells and for inner cells. Also, the hypothesis of radial streaming velocity being of second order in a Mach number expansion, is not valid at high amplitudes. The change of regime occurs when the radial streaming velocity amplitude becomes larger than the radial acoustic velocity amplitude, high levels being therefore characterized by nonlinear interaction of the different velocity components.

  4. Controlling sound with acoustic metamaterials

    DEFF Research Database (Denmark)

    Cummer, Steven A. ; Christensen, Johan; Alù, Andrea

    2016-01-01

    Acoustic metamaterials can manipulate and control sound waves in ways that are not possible in conventional materials. Metamaterials with zero, or even negative, refractive index for sound offer new possibilities for acoustic imaging and for the control of sound at subwavelength scales....... The combination of transformation acoustics theory and highly anisotropic acoustic metamaterials enables precise control over the deformation of sound fields, which can be used, for example, to hide or cloak objects from incident acoustic energy. Active acoustic metamaterials use external control to create......-scale metamaterial structures and converting laboratory experiments into useful devices. In this Review, we outline the designs and properties of materials with unusual acoustic parameters (for example, negative refractive index), discuss examples of extreme manipulation of sound and, finally, provide an overview...

  5. Adefovir-Induced Hypophosphatemic Osteomalacia Mimicking Bone Metastases From Primary Hepatocarcinoma.

    Science.gov (United States)

    Wei, Wei-Jun; Sun, Zhen-Kui; Shen, Chen-Tian; Qiu, Zhong-Ling; Luo, Quan-Yong

    2017-09-01

    Adefovir-induced hypophosphatemic osteomalacia in the context of hepatocarcinoma is rare and needs to be differentiated from metastatic hepatocarcinoma. We here report a case of severe osteomalacia whose focal uptakes of radiotracer on the Tc-MDP SPECT/CT images mimicked that of metastatic hepatocarcinoma.

  6. Education in acoustics in Argentina

    Science.gov (United States)

    Miyara, Federico

    2002-11-01

    Over the last decades, education in acoustics (EA) in Argentina has experienced ups and downs due to economic and political issues interfering with long term projects. Unlike other countries, like Chile, where EA has reached maturity in spite of the acoustical industry having shown little development, Argentina has several well-established manufacturers of acoustic materials and equipment but no specific career with a major in acoustics. At the university level, acoustics is taught as a complementary--often elective--course for careers such as architecture, communication engineering, or music. In spite of this there are several research centers with programs covering environmental and community noise, effects of noise on man, acoustic signal processing, musical acoustics and acoustic emission, and several national and international meetings are held each year in which results are communicated and discussed. Several books on a variety of topics such as sound system, architectural acoustics, and noise control have been published as well. Another chapter in EA is technical and vocational education, ranging between secondary and postsecondary levels, with technical training on sound system operation or design. Over the last years there have been several attempts to implement master degrees in acoustics or audio engineering, with little or no success.

  7. Review of Progress in Acoustic Levitation

    Science.gov (United States)

    Andrade, Marco A. B.; Pérez, Nicolás; Adamowski, Julio C.

    2018-04-01

    Acoustic levitation uses acoustic radiation forces to counteract gravity and suspend objects in mid-air. Although acoustic levitation was first demonstrated almost a century ago, for a long time, it was limited to objects much smaller than the acoustic wavelength levitating at fixed positions in space. Recent advances in acoustic levitation now allow not only suspending but also rotating and translating objects in three dimensions. Acoustic levitation is also no longer restricted to small objects and can now be employed to levitate objects larger than the acoustic wavelength. This article reviews the progress of acoustic levitation, focusing on the working mechanism of different types of acoustic levitation devices developed to date. We start with a brief review of the theory. Then, we review the acoustic levitation methods to suspend objects at fixed positions, followed by the techniques that allow the manipulation of objects. Finally, we present a brief summary and offer some future perspectives for acoustic levitation.

  8. Polyvinyl chloride as a multimodal tissue-mimicking material with tuned mechanical and medical imaging properties.

    Science.gov (United States)

    Li, Weisi; Belmont, Barry; Greve, Joan M; Manders, Adam B; Downey, Brian C; Zhang, Xi; Xu, Zhen; Guo, Dongming; Shih, Albert

    2016-10-01

    The mechanical and imaging properties of polyvinyl chloride (PVC) can be adjusted to meet the needs of researchers as a tissue-mimicking material. For instance, the hardness can be adjusted by changing the ratio of softener to PVC polymer, mineral oil can be added for lubrication in needle insertion, and glass beads can be added to scatter acoustic energy similar to biological tissue. Through this research, the authors sought to develop a regression model to design formulations of PVC with targeted mechanical and multimodal medical imaging properties. The design of experiment was conducted by varying three factors-(1) the ratio of softener to PVC polymer, (2) the mass fraction of mineral oil, and (3) the mass fraction of glass beads-and measuring the mechanical properties (elastic modulus, hardness, viscoelastic relaxation time constant, and needle insertion friction force) and the medical imaging properties [speed of sound, acoustic attenuation coefficient, magnetic resonance imaging time constants T 1 and T 2 , and the transmittance of the visible light at wavelengths of 695 nm (T λ695 ) and 532 nm (T λ532 )] on twelve soft PVC samples. A regression model was built to describe the relationship between the mechanical and medical imaging properties and the values of the three composition factors of PVC. The model was validated by testing the properties of a PVC sample with a formulation distinct from the twelve samples. The tested soft PVC had elastic moduli from 6 to 45 kPa, hardnesses from 5 to 50 Shore OOO-S, viscoelastic stress relaxation time constants from 114.1 to 191.9 s, friction forces of 18 gauge needle insertion from 0.005 to 0.086 N/mm, speeds of sound from 1393 to 1407 m/s, acoustic attenuation coefficients from 0.38 to 0.61 (dB/cm)/MHz, T 1 relaxation times from 426.3 to 450.2 ms, T 2 relaxation times from 21.5 to 28.4 ms, T λ695 from 46.8% to 92.6%, and T λ532 from 41.1% to 86.3%. Statistically significant factors of each property were

  9. Interaction of surface plasmon polaritons and acoustic waves inside an acoustic cavity.

    Science.gov (United States)

    Khokhlov, Nikolai; Knyazev, Grigoriy; Glavin, Boris; Shtykov, Yakov; Romanov, Oleg; Belotelov, Vladimir

    2017-09-15

    In this Letter, we introduce an approach for manipulation of active plasmon polaritons via acoustic waves at sub-terahertz frequency range. The acoustic structures considered are designed as phononic Fabry-Perot microresonators where mirrors are presented with an acoustic superlattice and the structure's surface, and a plasmonic grating is placed on top of the acoustic cavity so formed. It provides phonon localization in the vicinity of the plasmonic grating at frequencies within the phononic stop band enhancing phonon-light interaction. We consider phonon excitation by shining a femtosecond laser pulse on the plasmonic grating. Appropriate theoretical model was used to describe the acoustic process caused by the pump laser pulse in the GaAs/AlAs-based acoustic cavity with a gold grating on top. Strongest modulation is achieved upon excitation of propagating surface plasmon polaritons and hybridization of propagating and localized plasmons. The relative changes in the optical reflectivity of the structure are more than an order of magnitude higher than for the structure without the plasmonic film.

  10. SU-F-T-433: Evaluation of a New Dose Mimicking Application for Clinical Flexibility and Reliability

    International Nuclear Information System (INIS)

    Hoffman, D; Nair, C Kumaran; Wright, C; Yamamoto, T; Mayadev, J; Valicenti, R; Benedict, S; Rong, Y; Markham, J

    2016-01-01

    Purpose: Clinical workflow and machine down time occasionally require patients to be temporarily treated on a system other than the initial treatment machine. A new commercial dose mimicking application provides automated cross-platform treatment planning to expedite this clinical flexibility. The aim of this work is to evaluate the feasibility of automatic plan creation and establish a robust clinical workflow for prostate and pelvis patients. Methods: Five prostate and five pelvis patients treated with helical plans were selected for re-planning with the dose mimicking application, covering both simple and complex scenarios. Two-arc VMAT and 7- and 9-field IMRT plans were generated for each case, with the objective function of achieving similar dose volume histogram from the initial helical plans. Dosimetric comparisons include target volumes and organs at risk (OARs) (rectum, bladder, small bowel, femoral heads, etc.). Dose mimicked plans were evaluated by a radiation oncologist, and patient-specific QAs were performed to validate delivery. Results: Overall plan generation and transfer required around 30 minutes of dosimetrist’s time once the dose-mimicking protocol is setup for each site. The resulting VMAT and 7- and 9-field IMRT plans achieved equivalent PTV coverage and homogeneity (D99/DRx = 97.3%, 97.2%, 97.2% and HI = 6.0, 5.8, and 5.9, respectively), compared to helical plans (97.6% and 4.6). The OAR dose discrepancies were up to 6% in rectum Dmean, but generally lower in bladder, femoral heads, bowel and penile bulb. In the context of 1–5 fractions, the radiation oncologist evaluated the dosimetric changes as not clinically significant. All delivery QAs achieved >90% pass with a 3%/3mm gamma criteria. Conclusion: The automated dose-mimicking workflow offers a strategy to avoid missing treatment fractions due to machine down time with non-clinically significant changes in dosimetry. Future work will further optimize dose mimicking plans and

  11. SU-F-T-433: Evaluation of a New Dose Mimicking Application for Clinical Flexibility and Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D; Nair, C Kumaran; Wright, C; Yamamoto, T; Mayadev, J; Valicenti, R; Benedict, S; Rong, Y [University of California Davis Medical Center, Sacramento, CA (United States); Markham, J [Raysearch Laboratories, Garden City, NY (United States)

    2016-06-15

    Purpose: Clinical workflow and machine down time occasionally require patients to be temporarily treated on a system other than the initial treatment machine. A new commercial dose mimicking application provides automated cross-platform treatment planning to expedite this clinical flexibility. The aim of this work is to evaluate the feasibility of automatic plan creation and establish a robust clinical workflow for prostate and pelvis patients. Methods: Five prostate and five pelvis patients treated with helical plans were selected for re-planning with the dose mimicking application, covering both simple and complex scenarios. Two-arc VMAT and 7- and 9-field IMRT plans were generated for each case, with the objective function of achieving similar dose volume histogram from the initial helical plans. Dosimetric comparisons include target volumes and organs at risk (OARs) (rectum, bladder, small bowel, femoral heads, etc.). Dose mimicked plans were evaluated by a radiation oncologist, and patient-specific QAs were performed to validate delivery. Results: Overall plan generation and transfer required around 30 minutes of dosimetrist’s time once the dose-mimicking protocol is setup for each site. The resulting VMAT and 7- and 9-field IMRT plans achieved equivalent PTV coverage and homogeneity (D99/DRx = 97.3%, 97.2%, 97.2% and HI = 6.0, 5.8, and 5.9, respectively), compared to helical plans (97.6% and 4.6). The OAR dose discrepancies were up to 6% in rectum Dmean, but generally lower in bladder, femoral heads, bowel and penile bulb. In the context of 1–5 fractions, the radiation oncologist evaluated the dosimetric changes as not clinically significant. All delivery QAs achieved >90% pass with a 3%/3mm gamma criteria. Conclusion: The automated dose-mimicking workflow offers a strategy to avoid missing treatment fractions due to machine down time with non-clinically significant changes in dosimetry. Future work will further optimize dose mimicking plans and

  12. An abdominal tuberculosis case mimicking an abdominal mass

    African Journals Online (AJOL)

    An abdominal tuberculosis case mimicking an abdominal mass. Derya Erdog˘ an a. , Yasemin Ta ¸scı Yıldız b. , Esin Cengiz Bodurog˘lu c and Naciye Go¨nu¨l Tanır d. Abdominal tuberculosis is rare in childhood. It may be difficult to diagnose as it mimics various disorders. We present a 12-year-old child with an unusual ...

  13. Acoustic biosensors.

    Science.gov (United States)

    Fogel, Ronen; Limson, Janice; Seshia, Ashwin A

    2016-06-30

    Resonant and acoustic wave devices have been researched for several decades for application in the gravimetric sensing of a variety of biological and chemical analytes. These devices operate by coupling the measurand (e.g. analyte adsorption) as a modulation in the physical properties of the acoustic wave (e.g. resonant frequency, acoustic velocity, dissipation) that can then be correlated with the amount of adsorbed analyte. These devices can also be miniaturized with advantages in terms of cost, size and scalability, as well as potential additional features including integration with microfluidics and electronics, scaled sensitivities associated with smaller dimensions and higher operational frequencies, the ability to multiplex detection across arrays of hundreds of devices embedded in a single chip, increased throughput and the ability to interrogate a wider range of modes including within the same device. Additionally, device fabrication is often compatible with semiconductor volume batch manufacturing techniques enabling cost scalability and a high degree of precision and reproducibility in the manufacturing process. Integration with microfluidics handling also enables suitable sample pre-processing/separation/purification/amplification steps that could improve selectivity and the overall signal-to-noise ratio. Three device types are reviewed here: (i) bulk acoustic wave sensors, (ii) surface acoustic wave sensors, and (iii) micro/nano-electromechanical system (MEMS/NEMS) sensors. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  14. Passive acoustic mapping of magnetic microbubbles for cavitation enhancement and localization

    International Nuclear Information System (INIS)

    Crake, Calum; Victor, Marie de Saint; Owen, Joshua; Coviello, Christian; Collin, Jamie; Coussios, Constantin-C; Stride, Eleanor

    2015-01-01

    Magnetic targeting of microbubbles functionalized with superparamagnetic nanoparticles has been demonstrated previously for diagnostic (B-mode) ultrasound imaging and shown to enhance gene delivery in vitro and in vivo. In the present work, passive acoustic mapping (PAM) was used to investigate the potential of magnetic microbubbles for localizing and enhancing cavitation activity under focused ultrasound. Suspensions of magnetic microbubbles consisting of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), air and 10 nm diameter iron oxide nanoparticles were injected into a tissue mimicking phantom at different flow velocities (from 0 to 50 mm s −1 ) with or without an applied magnetic field. Microbubbles were excited using a 500 kHz single element focused transducer at peak negative focal pressures of 0.1–1.0 MPa, while a 64 channel imaging array passively recorded their acoustic emissions. Magnetic localization of microbubble-induced cavitation activity was successfully achieved and could be resolved using PAM as a shift in the spatial distribution and increases in the intensity and sustainability of cavitation activity under the influence of a magnetic field. Under flow conditions at shear rates of up to 100 s −1 targeting efficacy was maintained. Application of a magnetic field was shown to consistently increase the energy of cavitation emissions by a factor of 2–5 times over the duration of exposures compared to the case without targeting, which was approximately equivalent to doubling the injected microbubble dose. These results suggest that magnetic targeting could be used to localize and increase the concentration of microbubbles and hence cavitation activity for a given systemic dose of microbubbles or ultrasound intensity. (paper)

  15. Neoplastic stomach lesions and their mimickers: spectrum of imaging manifestations

    OpenAIRE

    Virmani, Vivek; Khandelwal, Ashish; Sethi, Vineeta; Fraser-Hill, Margret; Fasih, Najla; Kielar, Ania

    2012-01-01

    Abstract This review illustrates a wide spectrum of gastric neoplasms with emphasis on imaging findings helpful in characterizing various gastric neoplasms. Both the malignant and benign neoplasms along with focal gastric masses mimicking tumour are illustrated. Moreover, imaging clues to reach an accurate diagnosis are emphasized.

  16. Mimicking expressiveness of movements by autistic children in game play

    NARCIS (Netherlands)

    Tetteroo, D.; Shirzad, A.; Serras Pereira, M.; Zwinderman, M.J.; Duy, L.; Barakova, E.I.

    2012-01-01

    Children with Autistic Spectrum Disorder (ASD)have marked impairments in social interaction. Imitation is a basic social interaction behavior, and mimicking as an element of imitation can be a diagnostic marker for autism and thus a skill that can be targeted by behavioral training. In a comparative

  17. Heparin-mimicking multilayer coating on polymeric membrane via LbL assembly of cyclodextrin-based supramolecules.

    Science.gov (United States)

    Deng, Jie; Liu, Xinyue; Ma, Lang; Cheng, Chong; Shi, Wenbin; Nie, Chuanxiong; Zhao, Changsheng

    2014-12-10

    In this study, multifunctional and heparin-mimicking star-shaped supramolecules-deposited 3D porous multilayer films with improved biocompatibility were fabricated via a layer-by-layer (LbL) self-assembly method on polymeric membrane substrates. Star-shaped heparin-mimicking polyanions (including poly(styrenesulfonate-co-sodium acrylate; Star-PSS-AANa) and poly(styrenesulfonate-co-poly(ethylene glycol)methyl ether methacrylate; Star-PSS-EGMA)) and polycations (poly(methyl chloride-quaternized 2-(dimethylamino)ethyl methacrylate; Star-PMeDMA) were first synthesized by atom transfer radical polymerization (ATRP) from β-cyclodextrin (β-CD) based cores. Then assembly of 3D porous multilayers onto polymeric membrane surfaces was carried out by alternating deposition of the polyanions and polycations via electrostatic interaction. The surface morphology and composition, water contact angle, blood activation, and thrombotic potential as well as cell viability for the coated heparin-mimicking films were systematically investigated. The results of surface ATR-FTIR spectra and XPS spectra verified successful deposition of the star-shaped supramolecules onto the biomedical membrane surfaces; scanning electron microscopy (SEM) and atomic force microscopy (AFM) observations revealed that the modified substrate had 3D porous surface morphology, which might have a great biological influence on the biointerface. Furthermore, systematic in vitro investigation of protein adsorption, platelet adhesion, human platelet factor 4 (PF4, indicates platelet activation), activate partial thromboplastin time (APTT), thrombin time (TT), coagulation activation (thrombin-antithrombin III complex (TAT, indicates blood coagulant)), and blood-related complement activation (C3a and C5a, indicates inflammation potential) confirmed that the heparin-mimicking multilayer coated membranes exhibited ultralow blood component activations and excellent hemocompatibility. Meanwhile, after surface coating

  18. Cave acoustics in prehistory: Exploring the association of Palaeolithic visual motifs and acoustic response.

    Science.gov (United States)

    Fazenda, Bruno; Scarre, Chris; Till, Rupert; Pasalodos, Raquel Jiménez; Guerra, Manuel Rojo; Tejedor, Cristina; Peredo, Roberto Ontañón; Watson, Aaron; Wyatt, Simon; Benito, Carlos García; Drinkall, Helen; Foulds, Frederick

    2017-09-01

    During the 1980 s, acoustic studies of Upper Palaeolithic imagery in French caves-using the technology then available-suggested a relationship between acoustic response and the location of visual motifs. This paper presents an investigation, using modern acoustic measurement techniques, into such relationships within the caves of La Garma, Las Chimeneas, La Pasiega, El Castillo, and Tito Bustillo in Northern Spain. It addresses methodological issues concerning acoustic measurement at enclosed archaeological sites and outlines a general framework for extraction of acoustic features that may be used to support archaeological hypotheses. The analysis explores possible associations between the position of visual motifs (which may be up to 40 000 yrs old) and localized acoustic responses. Results suggest that motifs, in general, and lines and dots, in particular, are statistically more likely to be found in places where reverberation is moderate and where the low frequency acoustic response has evidence of resonant behavior. The work presented suggests that an association of the location of Palaeolithic motifs with acoustic features is a statistically weak but tenable hypothesis, and that an appreciation of sound could have influenced behavior among Palaeolithic societies of this region.

  19. The effects of two counterpropagating surface acoustic wave beams on single electron acoustic charge transport

    International Nuclear Information System (INIS)

    He Jianhong; Guo Huazhong; Song Li; Zhang Wei; Gao Jie; Lu Chuan

    2010-01-01

    We present a comprehensive study of the effects of two counterpropagating surface acoustic waves on the acoustoelectric current of single electron transport devices. A significant improvement in the accuracy of current quantization is achieved as a result of an additional surface acoustic wave beam. The experiments reveal the sinusoidally periodical modulation in the acoustoelectric current characteristic as a function of the relative phase of the two surface acoustic wave beams. Besides, by using standing surface acoustic waves, the acoustoelectric current is detected which we consider as the so-called anomalous acoustoelectric current produced by acoustic wave mechanical deformations. This kind current is contributed to one component of the acoustoelectric current in surface acoustic wave device, which could enable us to establish a more adequate description of acoustoelectric effects on single-electron acoustic charge transport.

  20. Localized Acoustic Surface Modes

    KAUST Repository

    Farhat, Mohamed

    2015-08-04

    We introduce the concept of localized acoustic surface modes (ASMs). We demonstrate that they are induced on a two-dimensional cylindrical rigid surface with subwavelength corrugations under excitation by an incident acoustic plane wave. Our results show that the corrugated rigid surface is acoustically equivalent to a cylindrical scatterer with uniform mass density that can be represented using a Drude-like model. This, indeed, suggests that plasmonic-like acoustic materials can be engineered with potential applications in various areas including sensing, imaging, and cloaking.

  1. Acoustic Signals and Systems

    DEFF Research Database (Denmark)

    2008-01-01

    The Handbook of Signal Processing in Acoustics will compile the techniques and applications of signal processing as they are used in the many varied areas of Acoustics. The Handbook will emphasize the interdisciplinary nature of signal processing in acoustics. Each Section of the Handbook...... will present topics on signal processing which are important in a specific area of acoustics. These will be of interest to specialists in these areas because they will be presented from their technical perspective, rather than a generic engineering approach to signal processing. Non-specialists, or specialists...... from different areas, will find the self-contained chapters accessible and will be interested in the similarities and differences between the approaches and techniques used in different areas of acoustics....

  2. Optical measurement of acoustic radiation pressure of the near-field acoustic levitation through transparent object

    OpenAIRE

    Nakamura, Satoshi; Furusawa, Toshiaki; Sasao, Yasuhiro; Katsura, Kogure; Naoki, Kondo

    2013-01-01

    It is known that macroscopic objects can be levitated for few to several hundred micrometers by near-field acoustic field and this phenomenon is called near-field acoustic levitation (NFAL). Although there are various experiments conducted to measure integrated acoustic pressure on the object surface, up to now there was no direct method to measure pressure distribution. In this study we measured the acoustic radiation pressure of the near-field acoustic levitation via pressure-sensitive paint.

  3. Primary Benign Intraosseous Meningioma on {sup 18}F-FDG PET/CT Mimicking Malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Seong; Kim, Seok Hwi; Kim, Hyung Jin; Kang, Se Woong; Kim, Soo Jeong; Lee, Joo Hee; Hong, Sun Pyo; Cho, Young Seok; Choi, Joon Young [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)

    2014-06-15

    We present a case of primary benign intraosseous meningioma in the sphenoid bone mimicking malignancy. A 44-year-old female patient who had a protruding right eye and headache came to our hospital. MRI showed a large, destructive, heterogeneously well-enhancing soft tissue mass in the right sphenoid bone suggesting malignancy. {sup 18}F-FDG PET/CT showed a hypermetabolic mass in the same site with an SUV{sub max} of 9.1 The pathological diagnosis by surgery revealed that this tumor was a WHO grade I transitional meningioma. This case suggests that primary benign intraosseous meningioma may show high {sup 18}F-FDG uptake mimicking a malignancy.

  4. Observation of self-excited acoustic vortices in defect-mediated dust acoustic wave turbulence.

    Science.gov (United States)

    Tsai, Ya-Yi; I, Lin

    2014-07-01

    Using the self-excited dust acoustic wave as a platform, we demonstrate experimental observation of self-excited fluctuating acoustic vortex pairs with ± 1 topological charges through spontaneous waveform undulation in defect-mediated turbulence for three-dimensional traveling nonlinear longitudinal waves. The acoustic vortex pair has helical waveforms with opposite chirality around the low-density hole filament pair in xyt space (the xy plane is the plane normal to the wave propagation direction). It is generated through ruptures of sequential crest surfaces and reconnections with their trailing ruptured crest surfaces. The initial rupture is originated from the amplitude reduction induced by the formation of the kinked wave crest strip with strong stretching through the undulation instability. Increasing rupture causes the separation of the acoustic vortex pair after generation. A similar reverse process is followed for the acoustic vortex annihilating with the opposite-charged acoustic vortex from the same or another pair generation.

  5. Subdural Hematoma Mimickers: A Systematic Review.

    Science.gov (United States)

    Catana, Dragos; Koziarz, Alex; Cenic, Aleksa; Nath, Siddharth; Singh, Sheila; Almenawer, Saleh A; Kachur, Edward

    2016-09-01

    A variety of subdural pathologies that may mimic hematomas are reported in the literature. We aimed to identify the atypical clinical and radiologic presentations of subdural masses that may mimic subdural hematomas. A systematic review of MEDLINE and Embase was conducted independently by 2 reviewers to identify articles describing subdural hematoma mimickers. We also present a patient from our institution with a subdural pathology mimicking a subdural hematoma. We analyzed patient clinical presentations, underlying pathologies, radiologic findings, and clinical outcomes. We included 43 articles totaling 48 patients. The mean ± SD patient age was 55.7 ± 16.8 years. Of the 45 cases describing patient history, 13 patients (27%) had a history of trauma. The underlying pathologies of the 48 subdural collections were 10 metastasis (21%), 14 lymphoma (29%), 7 sarcoma (15%), 4 infectious (8%), 4 autoimmune (8%), and 9 miscellaneous (19%). Findings on computed tomography (CT) scan were 18 hyperdense (41%), 11 hypodense (25%), 9 isodense (20%), 3 isodense/hyperdense (7%), and 3 hypodense/isodense (7%). Thirty-four patients (71%) were treated surgically; among these patients, 65% had symptom resolution. Neither the pathology (P = 0.337) nor the management strategy (P = 0.671) was correlated with improved functional outcomes. Identification of atypical history and radiologic features should prompt further diagnostic tests, including magnetic resonance imaging (MRI), to elucidate the proper diagnosis, given that certain pathologies may be managed nonsurgically. A subdural collection that is hyperdense on CT scan and hyperintense on T2-weighted MRI, along with a history of progressive headache with no trauma, may raise the suspicion of an atypical subdural pathology. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Acoustic Emission Technology and Application

    International Nuclear Information System (INIS)

    Joo, Y. S.; Lim, S. H.; Eom, H. S.; Kim, J. H.; Jung, H. K.

    2003-10-01

    Acoustic emission is the elastic wave that is generated by the rapid release of energy from the localized sources within a material. After the observation of acoustic emission phenomenon in 1950, the research and further investigation had been performed. Acoustic emission examination becomes a rapidly matured nondestructive testing method with demonstrated capabilities for characterizing material behavior and for detecting the defect. It is of interest as a possible passive monitoring technique for detecting, locating and characterizing the defects in component and structure. Acoustic emission technology has recently strengthened the on-line monitoring application for the detection of incipient failures and the assurance of structural integrity. The field of acoustic emission testing is still growing vigorously and presents many challenges. Especially, acoustic emission has been successfully applied in the leak detection of primary pressure boundary of nuclear power plants. In this state-of-art report, the principle, measurement and field applications of acoustic emission technique is reviewed and summarized. Acoustic emission technology will contribute to the assurance of nuclear safety as the on-line monitoring technique of structural integrity of NSSS components and structures

  7. Primary Papillary Mucinous Adenocarcinoma of the Ureter Mimicking Genitourinary Tuberculosis

    Science.gov (United States)

    Gulwani, Hanni; Jain, Aruna

    2010-01-01

    Primary adenocarcinomas of the renal pelvis and ureter are rare and account for less than 1% of all malignancies at this site. We report a case of primary papillary mucinous adenocarcinoma of the ureter that clinically mimicked genitourinary tuberculosis. Early diagnosis is important for the better outcome. PMID:21151719

  8. Acoustic building infiltration measurement system

    Science.gov (United States)

    Muehleisen, Ralph T.; Raman, Ganesh

    2018-04-10

    Systems and methods of detecting and identifying a leak from a container or building. Acoustic pressure and velocity are measured. Acoustic properties are acquired from the measured values. The acoustic properties are converted to infiltration/leakage information. Nearfield Acoustic Holography (NAH) may be one method to detect the leakages from a container by locating the noise sources.

  9. The accidental (acoustical) tourist

    Science.gov (United States)

    Van Kirk, Wayne

    2002-11-01

    The acoustical phenomenon observed at an ancient temple in the Great Ball Court at Chichen Itza was described as ''little short of amazing--an ancient whispering gallery'' by Silvanus G. Morley, leader of the Carnegie Institute's archaeological team that excavated and restored these structures in the 1920s. Since then, many others have experienced the extraordinary acoustics at Chichen Itza and other Maya sites. Despite these reports, archaeologists and acousticians have until recently shown little interest in understanding these phenomena. After experiencing Chichen Itza's remarkable acoustics as a tourist in 1994, the author commenced collecting and disseminating information about acoustical phenomena there and at other Mayan sites, hoping to stimulate interest among archaeologists and acousticians. Were these designs accidental or intentional? If intentional, how was the knowledge obtained? How were acoustical features used? This paper highlights the author's collection of anecdotal reports of mysterious Mayan acoustics (http://http://www.ianlawton.com/pa1.htm), recommended reading for scientists and engineers who wish to pursue this fascinating study. Also recounted are some of the reactions of archaeologists-ranging from curious, helpful, and insightful to humorous and appalling--to outsiders' efforts to bring serious scientific attention to the new field of acoustical archaeology.

  10. Acoustic field modulation in regenerators

    Science.gov (United States)

    Hu, J. Y.; Wang, W.; Luo, E. C.; Chen, Y. Y.

    2016-12-01

    The regenerator is a key component that transfers energy between heat and work. The conversion efficiency is significantly influenced by the acoustic field in the regenerator. Much effort has been spent to quantitatively determine this influence, but few comprehensive experimental verifications have been performed because of difficulties in modulating and measuring the acoustic field. In this paper, a method requiring two compressors is introduced and theoretically investigated that achieves acoustic field modulation in the regenerator. One compressor outputs the acoustic power for the regenerator; the other acts as a phase shifter. A RC load dissipates the acoustic power out of both the regenerator and the latter compressor. The acoustic field can be modulated by adjusting the current in the two compressors and opening the RC load. The acoustic field is measured with pressure sensors instead of flow-field imaging equipment, thereby greatly simplifying the experiment.

  11. Ares I Scale Model Acoustic Tests Instrumentation for Acoustic and Pressure Measurements

    Science.gov (United States)

    Vargas, Magda B.; Counter, Douglas D.

    2011-01-01

    The Ares I Scale Model Acoustic Test (ASMAT) was a development test performed at the Marshall Space Flight Center (MSFC) East Test Area (ETA) Test Stand 116. The test article included a 5% scale Ares I vehicle model and tower mounted on the Mobile Launcher. Acoustic and pressure data were measured by approximately 200 instruments located throughout the test article. There were four primary ASMAT instrument suites: ignition overpressure (IOP), lift-off acoustics (LOA), ground acoustics (GA), and spatial correlation (SC). Each instrumentation suite incorporated different sensor models which were selected based upon measurement requirements. These requirements included the type of measurement, exposure to the environment, instrumentation check-outs and data acquisition. The sensors were attached to the test article using different mounts and brackets dependent upon the location of the sensor. This presentation addresses the observed effect of the sensors and mounts on the acoustic and pressure measurements.

  12. Agorá Acoustics - Effects of arcades on the acoustics of public squares

    DEFF Research Database (Denmark)

    Paini, Dario; Gade, Anders Christian; Rindel, Jens Holger

    2005-01-01

    This paper is part of a PhD work, dealing with the acoustics of the public squares (‘Agorá Acoustics’), especially when music (amplified or not) is played. Consequently, our approach will be to evaluate public squares using the same set of acoustics concepts for subjective evaluation and objective...... measurements as applied for concert halls and theatres. In this paper the acoustical effects of arcades will be studied, in terms of reverberation (EDT and T30), clarity (C80), intelligibility (STI) and other acoustical parameters. For this purpose, also the theory of coupled rooms is applied and compared...... with results. An acoustic modelling program, ODEON 7.0, was used for this investigation. Three different sizes of public squares were considered. In order to evaluate the ‘real’ effects of the arcades on the open square, models of all three squares were designed both with and without arcades. The sound source...

  13. Understanding acoustics an experimentalist’s view of acoustics and vibration

    CERN Document Server

    Garrett, Steven L

    2017-01-01

    This textbook provides a unified approach to acoustics and vibration suitable for use in advanced undergraduate and first-year graduate courses on vibration and fluids. The book includes thorough treatment of vibration of harmonic oscillators, coupled oscillators, isotropic elasticity, and waves in solids including the use of resonance techniques for determination of elastic moduli. Drawing on 35 years of experience teaching introductory graduate acoustics at the Naval Postgraduate School and Penn State, the author presents a hydrodynamic approach to the acoustics of sound in fluids that provides a uniform methodology for analysis of lumped-element systems and wave propagation that can incorporate attenuation mechanisms and complex media. This view provides a consistent and reliable approach that can be extended with confidence to more complex fluids and future applications. Understanding Acoustics opens with a mathematical introduction that includes graphing and statistical uncertainty, followed by five chap...

  14. Hypertrophic Nonunion Humerus Mimicking an Enchondroma

    Directory of Open Access Journals (Sweden)

    N. K. Magu

    2014-01-01

    Full Text Available Introduction. Although fractures of humeral shaft show excellent results with conservative management, nonunion does occur. Case Report. We bring forth the case of a young male with a 1.5-year-old hypertrophic nonunion of the humerus mimicking an enchondroma. The initial X-ray images of the patient appeared to be an enchondroma, which only on further evaluation and histopathological analysis was diagnosed conclusively to be a hypertrophic nonunion. Discussion. Enchondromas are often incidentally diagnosed benign tumours. It is however not common to misdiagnose a hypertrophic nonunion to be an enchondroma. We present this case to highlight the unique diagnostic dilemma the treating team had to face.

  15. Cogan's syndrome mimicking acute Lyme arthritis.

    Science.gov (United States)

    Schwegmann, J P; Enzenauer, R J

    1995-05-01

    A pediatric case of Cogan's syndrome mimicking acute Lyme arthritis is described. A 12-year-old black boy was admitted to the pediatric service for presumed right knee septic arthritis. Symptoms included acute pain and swelling with decreased range-of-motion. Although the patient's right knee symptoms and positive Lyme serology were consistent with a diagnosis of Lyme arthritis, the presence of sensorineural hearing loss and interstitial keratitis with inflammatory arthritis suggested a diagnosis of Cogan's syndrome. Subsequent Western blot analysis was negative for Borrelia burgdorferi antigens. The patient had dramatic clinical improvement of musculoskeletal and ophthalmologic complaints shortly after receiving high-dose corticosteroids, although residual sensorineural hearing loss persisted.

  16. Investigation into the Effect of Acoustic Radiation Force and Acoustic Streaming on Particle Patterning in Acoustic Standing Wave Fields

    Directory of Open Access Journals (Sweden)

    Shilei Liu

    2017-07-01

    Full Text Available Acoustic standing waves have been widely used in trapping, patterning, and manipulating particles, whereas one barrier remains: the lack of understanding of force conditions on particles which mainly include acoustic radiation force (ARF and acoustic streaming (AS. In this paper, force conditions on micrometer size polystyrene microspheres in acoustic standing wave fields were investigated. The COMSOL® Mutiphysics particle tracing module was used to numerically simulate force conditions on various particles as a function of time. The velocity of particle movement was experimentally measured using particle imaging velocimetry (PIV. Through experimental and numerical simulation, the functions of ARF and AS in trapping and patterning were analyzed. It is shown that ARF is dominant in trapping and patterning large particles while the impact of AS increases rapidly with decreasing particle size. The combination of using both ARF and AS for medium size particles can obtain different patterns with only using ARF. Findings of the present study will aid the design of acoustic-driven microfluidic devices to increase the diversity of particle patterning.

  17. Investigation into the Effect of Acoustic Radiation Force and Acoustic Streaming on Particle Patterning in Acoustic Standing Wave Fields

    Science.gov (United States)

    Yang, Yanye; Ni, Zhengyang; Guo, Xiasheng; Luo, Linjiao; Tu, Juan; Zhang, Dong

    2017-01-01

    Acoustic standing waves have been widely used in trapping, patterning, and manipulating particles, whereas one barrier remains: the lack of understanding of force conditions on particles which mainly include acoustic radiation force (ARF) and acoustic streaming (AS). In this paper, force conditions on micrometer size polystyrene microspheres in acoustic standing wave fields were investigated. The COMSOL® Mutiphysics particle tracing module was used to numerically simulate force conditions on various particles as a function of time. The velocity of particle movement was experimentally measured using particle imaging velocimetry (PIV). Through experimental and numerical simulation, the functions of ARF and AS in trapping and patterning were analyzed. It is shown that ARF is dominant in trapping and patterning large particles while the impact of AS increases rapidly with decreasing particle size. The combination of using both ARF and AS for medium size particles can obtain different patterns with only using ARF. Findings of the present study will aid the design of acoustic-driven microfluidic devices to increase the diversity of particle patterning. PMID:28753955

  18. Remote Cutaneous Breast Carcinoma Metastasis Mimicking Dermatitis

    Directory of Open Access Journals (Sweden)

    Annakan V Navaratnam

    2015-01-01

    Full Text Available Cutaneous metastases from primary internal malignancies are an uncommon presentation. Cutaneous metastases are more frequently seen in breast cancer than in any other visceral malignancy in women. Medical practitioners should be vigilant of the possibility of unusual presentations of metastatic disease in breast cancer patients with lobular carcinoma presenting as cutaneous lesions mimicking benign dermatological conditions. Herein, we present a case of a 75-year-old woman presenting with cutaneous lobular breast carcinoma metastases on her anterior right leg, which had previously been misdiagnosed as dermatitis for 9 years.

  19. Being Mimicked Increases Prosocial Behavior in 18-Month-Old Infants

    Science.gov (United States)

    Carpenter, Malinda; Uebel, Johanna; Tomasello, Michael

    2013-01-01

    Most previous research on imitation in infancy has focused on infants' learning of instrumental actions on objects. This study focused instead on the more social side of imitation, testing whether being mimicked increases prosocial behavior in infants, as it does in adults (van Baaren, Holland, Kawakami, & van Knippenberg, 2004).…

  20. Primary Papillary Mucinous Adenocarcinoma of the Ureter Mimicking Genitourinary Tuberculosis

    Directory of Open Access Journals (Sweden)

    Hanni Gulwani

    2010-01-01

    Full Text Available Primary adenocarcinomas of the renal pelvis and ureter are rare and account for less than 1% of all malignancies at this site. We report a case of primary papillary mucinous adenocarcinoma of the ureter that clinically mimicked genitourinary tuberculosis. Early diagnosis is important for the better outcome.

  1. Deep Water Acoustics

    Science.gov (United States)

    2016-06-28

    the Deep Water project and participate in the NPAL Workshops, including Art Baggeroer (MIT), J. Beron- Vera (UMiami), M. Brown (UMiami), T...Kathleen E . Wage. The North Pacific Acoustic Laboratory deep-water acoustic propagation experiments in the Philippine Sea. J. Acoust. Soc. Am., 134(4...estimate of the angle α during PhilSea09, made from ADCP measurements at the site of the DVLA. Sim. A B1 B2 B3 C D E F Prof. # 0 4 4 4 5 10 16 20 α

  2. Acoustic Levitation With Less Equipment

    Science.gov (United States)

    Barmatz, M. B.; Jacobi, N.

    1983-01-01

    Certain chamber shapes require fewer than three acoustic drivers. Levitation at center of spherical chamber attained using only one acoustic driver. Exitation of lowest spherical mode produces asymmetric acoustic potential well.

  3. Anisotropy of acoustic properties in paratellurite

    International Nuclear Information System (INIS)

    Parygin, Vladimir N.

    1996-01-01

    One of the peculiarities of the TeO 2 crystal consists of its strong acoustic anisotropy. This anisotropy demonstrates itself by acoustic energy walk-off and anisotropic distortion of an acoustic beam. Four constants completely characterise the acoustic anisotropy of the medium. In this paper these constants are calculated for various directions of the acoustic beam in crystal. (authors)

  4. Variable-Position Acoustic Levitation

    Science.gov (United States)

    Barmatz, M. B.; Stoneburner, J. D.; Jacobi, N.; Wang, T. G.

    1983-01-01

    Method of acoustic levitation supports objects at positions other than acoustic nodes. Acoustic force is varied so it balances gravitational (or other) force, thereby maintaining object at any position within equilibrium range. Levitation method applicable to containerless processing. Such objects as table-tennis balls, hollow plastic spheres, and balsa-wood spheres levitated in laboratory by new method.

  5. Photo-acoustic and video-acoustic methods for sensing distant sound sources

    Science.gov (United States)

    Slater, Dan; Kozacik, Stephen; Kelmelis, Eric

    2017-05-01

    Long range telescopic video imagery of distant terrestrial scenes, aircraft, rockets and other aerospace vehicles can be a powerful observational tool. But what about the associated acoustic activity? A new technology, Remote Acoustic Sensing (RAS), may provide a method to remotely listen to the acoustic activity near these distant objects. Local acoustic activity sometimes weakly modulates the ambient illumination in a way that can be remotely sensed. RAS is a new type of microphone that separates an acoustic transducer into two spatially separated components: 1) a naturally formed in situ acousto-optic modulator (AOM) located within the distant scene and 2) a remote sensing readout device that recovers the distant audio. These two elements are passively coupled over long distances at the speed of light by naturally occurring ambient light energy or other electromagnetic fields. Stereophonic, multichannel and acoustic beam forming are all possible using RAS techniques and when combined with high-definition video imagery it can help to provide a more cinema like immersive viewing experience. A practical implementation of a remote acousto-optic readout device can be a challenging engineering problem. The acoustic influence on the optical signal is generally weak and often with a strong bias term. The optical signal is further degraded by atmospheric seeing turbulence. In this paper, we consider two fundamentally different optical readout approaches: 1) a low pixel count photodiode based RAS photoreceiver and 2) audio extraction directly from a video stream. Most of our RAS experiments to date have used the first method for reasons of performance and simplicity. But there are potential advantages to extracting audio directly from a video stream. These advantages include the straight forward ability to work with multiple AOMs (useful for acoustic beam forming), simpler optical configurations, and a potential ability to use certain preexisting video recordings. However

  6. Gout: radiographic findings mimicking infection

    International Nuclear Information System (INIS)

    Rousseau, I.; Raymond-Tremblay, D.; Cardinal, E.; Beauregard, C.G.; Braunstein, E.M.; Saint-Pierre, A.

    2001-01-01

    Objective: To describe radiographic features of gout that may mimic infection. Design and patients: We report five patients with acute bacterial gout who presented with clinical as well as radiological findings mimicking acute bacterial septic arthritis or osteomyelitis. Three patients had delay in the appropriate treatment with the final diagnosis being established after needle aspiration and identification of urate crystals under polarized light microscopy. Two patients underwent digit amputation for not responding to antibiotic treatment and had histological findings confirming the diagnosis of gout. Conclusion: It is important for the radiologist to be aware of the radiological manifestations of acute gout that can resemble infection in order to avoid inappropriate diagnosis and delay in adequate treatment. The definitive diagnosis should rely on needle aspiration and a specific search for urate crystals. (orig.)

  7. Magnetoactive Acoustic Metamaterials.

    Science.gov (United States)

    Yu, Kunhao; Fang, Nicholas X; Huang, Guoliang; Wang, Qiming

    2018-04-11

    Acoustic metamaterials with negative constitutive parameters (modulus and/or mass density) have shown great potential in diverse applications ranging from sonic cloaking, abnormal refraction and superlensing, to noise canceling. In conventional acoustic metamaterials, the negative constitutive parameters are engineered via tailored structures with fixed geometries; therefore, the relationships between constitutive parameters and acoustic frequencies are typically fixed to form a 2D phase space once the structures are fabricated. Here, by means of a model system of magnetoactive lattice structures, stimuli-responsive acoustic metamaterials are demonstrated to be able to extend the 2D phase space to 3D through rapidly and repeatedly switching signs of constitutive parameters with remote magnetic fields. It is shown for the first time that effective modulus can be reversibly switched between positive and negative within controlled frequency regimes through lattice buckling modulated by theoretically predicted magnetic fields. The magnetically triggered negative-modulus and cavity-induced negative density are integrated to achieve flexible switching between single-negative and double-negative. This strategy opens promising avenues for remote, rapid, and reversible modulation of acoustic transportation, refraction, imaging, and focusing in subwavelength regimes. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Electron/electron acoustic instability

    International Nuclear Information System (INIS)

    Gary, S.P.

    1987-01-01

    The electron acoustic wave becomes a normal mode of an unmagnetized collisionless plasma in the presence of two electron components with similar densities, but strongly disparate temperatures. The characteristic frequency of this mode is the plasma frequency of the cooler electron component. If these two electron components have a relative drift speed several times the thermal speed of the cooler component, the electron/electron acoustic instability may arise. This paper describes the parametric dependences of the threshold drift speed and maximum growth rate of this instability, and compares these with the same properties of the electron/ion acoustic instability. Under the condition of zero current, the electron/ion acoustic instability typically has the lower threshold drift speed, so that observation of the electron/electron acoustic instability is a strong indication of the presence of an electrical current in the plasma

  9. Acoustic imaging system

    Science.gov (United States)

    Smith, Richard W.

    1979-01-01

    An acoustic imaging system for displaying an object viewed by a moving array of transducers as the array is pivoted about a fixed point within a given plane. A plurality of transducers are fixedly positioned and equally spaced within a laterally extending array and operatively directed to transmit and receive acoustic signals along substantially parallel transmission paths. The transducers are sequentially activated along the array to transmit and receive acoustic signals according to a preestablished sequence. Means are provided for generating output voltages for each reception of an acoustic signal, corresponding to the coordinate position of the object viewed as the array is pivoted. Receptions from each of the transducers are presented on the same display at coordinates corresponding to the actual position of the object viewed to form a plane view of the object scanned.

  10. Breast cancer cell behaviors on staged tumorigenesis-mimicking matrices derived from tumor cells at various malignant stages

    International Nuclear Information System (INIS)

    Hoshiba, Takashi; Tanaka, Masaru

    2013-01-01

    Highlights: •Models mimicking ECM in tumor with different malignancy were prepared. •Cancer cell proliferation was suppressed on benign tumor ECM. •Benign tumor cell proliferation was suppressed on cancerous ECM. •Chemoresistance of cancer cell was enhanced on cancerous ECM. -- Abstract: Extracellular matrix (ECM) has been focused to understand tumor progression in addition to the genetic mutation of cancer cells. Here, we prepared “staged tumorigenesis-mimicking matrices” which mimic in vivo ECM in tumor tissue at each malignant stage to understand the roles of ECM in tumor progression. Breast tumor cells, MDA-MB-231 (invasive), MCF-7 (non-invasive), and MCF-10A (benign) cells, were cultured to form their own ECM beneath the cells and formed ECM was prepared as staged tumorigenesis-mimicking matrices by decellularization treatment. Cells showed weak attachment on the matrices derived from MDA-MB-231 cancer cells. The proliferations of MDA-MB-231 and MCF-7 was promoted on the matrices derived from MDA-MB-231 cancer cells whereas MCF-10A cell proliferation was not promoted. MCF-10A cell proliferation was promoted on the matrices derived from MCF-10A cells. Chemoresistance of MDA-MB-231 cells against 5-fluorouracil increased on only matrices derived from MDA-MB-231 cells. Our results showed that the cells showed different behaviors on staged tumorigenesis-mimicking matrices according to the malignancy of cell sources for ECM preparation. Therefore, staged tumorigenesis-mimicking matrices might be a useful in vitro ECM models to investigate the roles of ECM in tumor progression

  11. Breast cancer cell behaviors on staged tumorigenesis-mimicking matrices derived from tumor cells at various malignant stages

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiba, Takashi [Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510 (Japan); International Center for Materials Nanoarchitectonics (MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Tanaka, Masaru, E-mail: tanaka@yz.yamagata-u.ac.jp [Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510 (Japan)

    2013-09-20

    Highlights: •Models mimicking ECM in tumor with different malignancy were prepared. •Cancer cell proliferation was suppressed on benign tumor ECM. •Benign tumor cell proliferation was suppressed on cancerous ECM. •Chemoresistance of cancer cell was enhanced on cancerous ECM. -- Abstract: Extracellular matrix (ECM) has been focused to understand tumor progression in addition to the genetic mutation of cancer cells. Here, we prepared “staged tumorigenesis-mimicking matrices” which mimic in vivo ECM in tumor tissue at each malignant stage to understand the roles of ECM in tumor progression. Breast tumor cells, MDA-MB-231 (invasive), MCF-7 (non-invasive), and MCF-10A (benign) cells, were cultured to form their own ECM beneath the cells and formed ECM was prepared as staged tumorigenesis-mimicking matrices by decellularization treatment. Cells showed weak attachment on the matrices derived from MDA-MB-231 cancer cells. The proliferations of MDA-MB-231 and MCF-7 was promoted on the matrices derived from MDA-MB-231 cancer cells whereas MCF-10A cell proliferation was not promoted. MCF-10A cell proliferation was promoted on the matrices derived from MCF-10A cells. Chemoresistance of MDA-MB-231 cells against 5-fluorouracil increased on only matrices derived from MDA-MB-231 cells. Our results showed that the cells showed different behaviors on staged tumorigenesis-mimicking matrices according to the malignancy of cell sources for ECM preparation. Therefore, staged tumorigenesis-mimicking matrices might be a useful in vitro ECM models to investigate the roles of ECM in tumor progression.

  12. Perspective: Acoustic metamaterials in transition

    KAUST Repository

    Wu, Ying

    2017-12-15

    Acoustic metamaterials derive their novel characteristics from the interaction between acoustic waves with designed structures. Since its inception seventeen years ago, the field has been driven by fundamental geometric and physical principles that guide the structure design rules as well as provide the basis for wave functionalities. Recent examples include resonance-based acoustic metasurfaces that offer flexible control of acoustic wave propagation such as focusing and re-direction; parity-time (PT)-symmetric acoustics that utilizes the general concept of pairing loss and gain to achieve perfect absorption at a single frequency; and topological phononics that can provide one-way edge state propagation. However, such novel functionalities are not without constraints. Metasurface elements rely on resonances to enhance their coupling to the incident wave; hence, its functionality is limited to a narrow frequency band. Topological phononics is the result of the special lattice symmetry that must be fixed at the fabrication stage. Overcoming such constraints naturally forms the basis for further developments. We identify two emergent directions: Integration of acoustic metamaterial elements for achieving broadband characteristics as well as acoustic wave manipulation tasks more complex than the single demonstrative functionality; and active acoustic metamaterials that can adapt to environment as well as to go beyond the constraints on the passive acoustic metamaterials. Examples of a successful recent integration of multi-resonators in achieving broadband sound absorption can be found in optimal sound-absorbing structures, which utilize causality constraint as a design tool in realizing the target-set absorption spectrum with a minimal sample thickness. Active acoustic metamaterials have also demonstrated the capability to tune bandgaps as well as to alter property of resonances in real time through stiffening of the spring constants, in addition to the PT symmetric

  13. Canada Basin Acoustic Propagation Experiment (CANAPE)

    Science.gov (United States)

    2015-09-30

    acoustic communications, acoustic navigation, or acoustic remote sensing of the ocean interior . RELATED PROJECTS The 2015 CANAPE pilot study was a...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Canada Basin Acoustic Propagation Experiment (CANAPE...ocean structure. Changes in sea ice and the water column affect both acoustic propagation and ambient noise. This implies that what was learned

  14. Transmission acoustic microscopy investigation

    Science.gov (United States)

    Maev, Roman; Kolosov, Oleg; Levin, Vadim; Lobkis, Oleg

    The nature of acoustic contrast, i.e. the connection of the amplitude and phase of the output signal of the acoustic microscope with the local values of the acoustic parameters of the sample (density, elasticity, viscosity) is a central problem of acoustic microscopy. A considerable number of studies have been devoted to the formation of the output signal of the reflection scanning acoustic microscope. For the transmission acoustic microscope (TAM) this problem has remained almost unstudied. Experimental investigation of the confocal system of the TAM was carried out on an independently manufactured laboratory mockup of the TAM with the working frequency of the 420 MHz. Acoustic lenses with the radius of curvature of about 500 microns and aperture angle of 45 deg were polished out in the end faces of two cylindrical sound conductors made from Al2O3 single crystals with an axis parallel to the axis C of the crystal (the length of the sound conductor is 20 mm; diameter, 6 mm). At the end faces of the sound conductor, opposite to the lenses, CdS transducers with a diameter of 2 mm were disposed. The electric channel of the TAM provided a possibility for registering the amplitude of the microscope output signal in the case of the dynamic range of the 50 dB.

  15. Cutaneous Silicone Granuloma Mimicking Breast Cancer after Ruptured Breast Implant

    Directory of Open Access Journals (Sweden)

    Waseem Asim Ghulam El-Charnoubi

    2011-01-01

    Full Text Available Cutaneous manifestations due to migration of silicone from ruptured implants are rare. Migrated silicone with cutaneous involvement has been found in the chest wall, abdominal wall, and lower extremities. We describe a case of cutaneous silicone granuloma in the breast exhibiting unusual growth mimicking breast cancer after a ruptured implant.

  16. Shallow-Water Mud Acoustics

    Science.gov (United States)

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Shallow-Water Mud Acoustics William L. Siegmann...models and methods that explain observed material and acoustic properties of different physical types of shallow-ocean mud sediments. Other goals...are to assess prior data relating to the acoustic properties of mud and to provide guidance in the development and interpretation of experiments. A

  17. Tutorial on architectural acoustics

    Science.gov (United States)

    Shaw, Neil; Talaske, Rick; Bistafa, Sylvio

    2002-11-01

    This tutorial is intended to provide an overview of current knowledge and practice in architectural acoustics. Topics covered will include basic concepts and history, acoustics of small rooms (small rooms for speech such as classrooms and meeting rooms, music studios, small critical listening spaces such as home theatres) and the acoustics of large rooms (larger assembly halls, auditoria, and performance halls).

  18. A Q fever case mimicking crimean-congo haemorrhagic fever

    Directory of Open Access Journals (Sweden)

    O Karabay

    2011-01-01

    Full Text Available Coxiella burnetii is the bacterium that causes Q fever. Human infection is mainly transmitted from cattle, goats and sheep. The disease is usually self-limited. Pneumonia and hepatitis are the most common clinical manifestations. In this study, we present a case of Q fever from the western part of Turkey mimicking Crimean-Congo haemorrhagic fever (CCHF in terms of clinical and laboratory findings.

  19. Micromachined silicon acoustic delay line with improved structural stability and acoustic directivity for real-time photoacoustic tomography

    Science.gov (United States)

    Cho, Young; Kumar, Akhil; Xu, Song; Zou, Jun

    2017-03-01

    Recent studies have shown that micromachined silicon acoustic delay lines can provide a promising solution to achieve real-time photoacoustic tomography without the need for complex transducer arrays and data acquisition electronics. However, as its length increases to provide longer delay time, the delay line becomes more vulnerable to structural instability due to reduced mechanical stiffness. In addition, the small cross-section area of the delay line results in a large acoustic acceptance angle and therefore poor directivity. To address these two issues, this paper reports the design, fabrication, and testing of a new silicon acoustic delay line enhanced with 3D printed polymer micro linker structures. First, mechanical deformation of the silicon acoustic delay line (with and without linker structures) under gravity was simulated by using finite element method. Second, the acoustic crosstalk and acoustic attenuation caused by the polymer micro linker structures were evaluated with both numerical simulation and ultrasound transmission testing. The result shows that the use of the polymer micro linker structures significantly improves the structural stability of the silicon acoustic delay lines without creating additional acoustic attenuation and crosstalk. In addition, a new tapered design for the input terminal of the delay line was also investigate to improve its acoustic directivity by reducing the acoustic acceptance angle. These two improvements are expected to provide an effective solution to eliminate current limitations on the achievable acoustic delay time and out-of-plane imaging resolution of micromachined silicon acoustic delay line arrays.

  20. Handbook of Engineering Acoustics

    CERN Document Server

    Möser, Michael

    2013-01-01

    This book examines the physical background of engineering acoustics, focusing on empirically obtained engineering experience as well as on measurement techniques and engineering methods for prognostics. Its goal is not only to describe the state of art of engineering acoustics but also to give practical help to engineers in order to solve acoustic problems. It deals with the origin, the transmission and the methods of the abating different kinds of air-borne and structure-borne sounds caused by various mechanisms – from traffic to machinery and flow-induced sound. In addition the modern aspects of room and building acoustics, as well as psychoacoustics and active noise control, are covered.

  1. Ion-acoustic plasma turbulence

    International Nuclear Information System (INIS)

    Bychenkov, V.Y.; Silin, V.P.

    1982-01-01

    A theory is developed of the nonlinear state that is established in a plasma as a result of development of ion-acoustic instability. Account is taken simultaneously of the linear induced scattering of the waves by the ions and of the quasilinear relaxation of the electrons by the ion-acoustic pulsations. The distribution of the ion-acoustic turbulence in frequency and in angle is obtained. An Ohm's law is established and expressions are obtained for the electronic heat flux and for the relaxation time of the electron temperature in a turbulent plasma. Anomalously large absorption and scattering of the electromagnetic waves by the ion-acoustic pulsations is predicted

  2. A new definition for acoustic dose

    International Nuclear Information System (INIS)

    Duck, F A

    2011-01-01

    This paper discusses a recent proposal for definitions of acoustic dose and acoustic dose-rate. Acoustic dose is defined as the energy deposited by absorption of an acoustic wave per unit mass of the medium supporting the wave. Its time-derivative, acoustic dose-rate, Q m , in W kg -1 is central to the prediction of both rate of temperature rise and radiation force. These quantities have spatial and temporal dependency, depending on the local field parameters (acoustic pressure, particle velocity, intensity) and local material properties (absorption coefficient, α a , and mass density, ρ 0 ). Spatial and/or temporal averaging can be applied where appropriate. For plane-wave monochromatic conditions in a homogeneous medium, Q m =2α a I/ρ 0 , (I is the time-averaged intensity), a simple expression which may also incorporate frequency dependencies of energy deposition. Acoustic dose and acoustic does-rate are exact analogues for Specific Absorption and Specific Absorption Rate (SAR), quantities central to radiofrequency (RF) and microwave dosimetry. Acoustic dosimetry in the presence of tissue/gas interfaces remains a considerable challenge.

  3. Fundamentals of Shallow Water Acoustics

    CERN Document Server

    Katsnelson, Boris; Lynch, James

    2012-01-01

    Shallow water acoustics (SWA), the study of how low and medium frequency sound propagates and scatters on the continental shelves of the world's oceans, has both technical interest and a large number of practical applications. Technically, shallow water poses an interesting medium for the study of acoustic scattering, inverse theory, and propagation physics in a complicated oceanic waveguide. Practically, shallow water acoustics has interest for geophysical exploration, marine mammal studies, and naval applications. Additionally, one notes the very interdisciplinary nature of shallow water acoustics, including acoustical physics, physical oceanography, marine geology, and marine biology. In this specialized volume, the authors, all of whom have extensive at-sea experience in U.S. and Russian research efforts, have tried to summarize the main experimental, theoretical, and computational results in shallow water acoustics, with an emphasis on providing physical insight into the topics presented.

  4. Sparganosis of the Breast that Mimicked Metastasis: A Case Report

    International Nuclear Information System (INIS)

    Kim, Jae Woon; Hwang, Mi Soo

    2011-01-01

    Sparganosis of the breast is a rare parasitic infection of humans. If the breast is involved, then this condition presents as soft tissue masses that mimic breast cancer. We report here on the radiologic feature of sparganosis in a patient with gastric cancer and this mimicked metastasis. We also briefly review the relevant literature

  5. The Development of the Acoustic Design of NASA Glenn Research Center's New Reverberant Acoustic Test Facility

    Science.gov (United States)

    Hughes, William O.; McNelis, Mark E.; Hozman, Aron D.; McNelis, Anne M.

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is leading the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC s Plum Brook Station in Sandusky, Ohio. Benham Companies, LLC is currently constructing modal, base-shake sine and reverberant acoustic test facilities to support the future testing needs of NASA s space exploration program. The large Reverberant Acoustic Test Facility (RATF) will be approximately 101,000 ft3 in volume and capable of achieving an empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world s known active reverberant acoustic test facilities. The key to achieving the expected acoustic test spectra for a range of many NASA space flight environments in the RATF is the knowledge gained from a series of ground acoustic tests. Data was obtained from several NASA-sponsored test programs, including testing performed at the National Research Council of Canada s acoustic test facility in Ottawa, Ontario, Canada, and at the Redstone Technical Test Center acoustic test facility in Huntsville, Alabama. The majority of these tests were performed to characterize the acoustic performance of the modulators (noise generators) and representative horns that would be required to meet the desired spectra, as well as to evaluate possible supplemental gas jet noise sources. The knowledge obtained in each of these test programs enabled the design of the RATF sound generation system to confidently advance to its final acoustic design and subsequent on-going construction.

  6. Select Internet Resources on Acoustics

    Directory of Open Access Journals (Sweden)

    Angela R. Davis

    2016-12-01

    Full Text Available Merriam-Webster (2016 defines acoustics as, “a science that deals with the production, control, transmission, reception, and effects of sounds.” According to Rossing (2014, the study of acoustics began in ancient Greece with Pythagoras’ study of vibrating strings on musical instruments. Since those early beginnings, famous scientists including Rayleigh, Alexander Graham Bell, and Thomas Edison, have helped expand the field of acoustics to include architectural, physical, engineering, structural, underwater, physiological and psychological, musical acoustics, and speech. Acoustics is a highly interdisciplinary field and researchers may need resources from physics, medicine, and engineering to understand all aspects of their research.

  7. Handbook of Signal Processing in Acoustics

    CERN Document Server

    Havelock, David; Vorländer, Michael

    2009-01-01

    The Handbook of Signal Processing in Acoustics presents signal processing as it is practiced in the field of acoustics. The Handbook is organized by areas of acoustics, with recognized leaders coordinating the self-contained chapters of each section. It brings together a wide range of perspectives from over 100 authors to reveal the interdisciplinary nature of signal processing in acoustics. Success in acoustic applications often requires juggling both the acoustic and the signal processing parameters of the problem. This handbook brings the key issues from both into perspective and is complementary to other reference material on the two subjects. It is a unique resource for experts and practitioners alike to find new ideas and techniques within the diversity of signal processing in acoustics.

  8. Orthokeratinised odontogenic cyst mimicking periapical cyst.

    Science.gov (United States)

    Rajalakshmi, R; Sreeja, C; Vijayalakshmi, D; Leelarani, V

    2013-10-07

    Orthokeratinised odontogenic cyst (OOC) denotes the odontogenic cyst that microscopically has an orthokeratinised epithelial lining. OOC is characterised by a less-aggressive behaviour and a low rate of recurrence. This report describes a case of OOC involving posterior part of the mandible that mimicked periapical cyst in a 14-year-old boy. The initial clinical diagnosis was given as periapical cyst based on the clinical and radiographical features. Enucleation of the cyst was performed and the specimen was sent for histopathological examination. A definite diagnosis of OOC was made by histopathological examination of the biopsy specimen. This case emphases on including OOC in the differential diagnosis of radiolucencies occurring in the periapical region of non-vital tooth.

  9. Mobile phone use and risk of brain neoplasms and other cancers: prospective study.

    Science.gov (United States)

    Benson, Victoria S; Pirie, Kirstin; Schüz, Joachim; Reeves, Gillian K; Beral, Valerie; Green, Jane

    2013-06-01

    Results from some retrospective studies suggest a possible increased risk of glioma and acoustic neuroma in users of mobile phones. The relation between mobile phone use and incidence of intracranial central nervous system (CNS) tumours and other cancers was examined in 791,710 middle-aged women in a UK prospective cohort, the Million Women Study. Cox regression models were used to estimate adjusted relative risks (RRs) and 95% confidence intervals (CIs). Women reported mobile phone use in 1999 to 2005 and again in 2009. During 7 years' follow-up, 51,680 incident invasive cancers and 1,261 incident intracranial CNS tumours occurred. Risk among ever vs never users of mobile phones was not increased for all intracranial CNS tumours (RR = 1.01, 95% CI = 0.90-1.14, P = 0.82), for specified CNS tumour types nor for cancer at 18 other specified sites. For long-term users compared with never users, there was no appreciable association for glioma (10+ years: RR = 0.78, 95% CI = 0.55-1.10, P = 0.16) or meningioma (10+ years: RR = 1.10, 95% CI = 0.66-1.84, P = 0.71). For acoustic neuroma, there was an increase in risk with long term use vs never use (10+ years: RR = 2.46, 95% CI = 1.07-5.64, P = 0.03), the risk increasing with duration of use (trend among users, P = 0.03). In this large prospective study, mobile phone use was not associated with increased incidence of glioma, meningioma or non-CNS cancers.

  10. Relaxation time of acoustically disturbed plasma

    International Nuclear Information System (INIS)

    Mkrtchyan, K.S.; Abrahamyan, A.S.

    2005-01-01

    The conservation time of an acoustic structure in plasma after relieving of external acoustic influence is investigated. Dependences of the conservation time on discharge parameters are presented. It is asserted that the plasma becomes an anisotropic uniaxial medium with an acoustic superlattice under the acoustic influence

  11. A hardware model of the auditory periphery to transduce acoustic signals into neural activity

    Directory of Open Access Journals (Sweden)

    Takashi eTateno

    2013-11-01

    Full Text Available To improve the performance of cochlear implants, we have integrated a microdevice into a model of the auditory periphery with the goal of creating a microprocessor. We constructed an artificial peripheral auditory system using a hybrid model in which polyvinylidene difluoride was used as a piezoelectric sensor to convert mechanical stimuli into electric signals. To produce frequency selectivity, the slit on a stainless steel base plate was designed such that the local resonance frequency of the membrane over the slit reflected the transfer function. In the acoustic sensor, electric signals were generated based on the piezoelectric effect from local stress in the membrane. The electrodes on the resonating plate produced relatively large electric output signals. The signals were fed into a computer model that mimicked some functions of inner hair cells, inner hair cell–auditory nerve synapses, and auditory nerve fibers. In general, the responses of the model to pure-tone burst and complex stimuli accurately represented the discharge rates of high-spontaneous-rate auditory nerve fibers across a range of frequencies greater than 1 kHz and middle to high sound pressure levels. Thus, the model provides a tool to understand information processing in the peripheral auditory system and a basic design for connecting artificial acoustic sensors to the peripheral auditory nervous system. Finally, we discuss the need for stimulus control with an appropriate model of the auditory periphery based on auditory brainstem responses that were electrically evoked by different temporal pulse patterns with the same pulse number.

  12. Airy acoustical-sheet spinner tweezers

    Science.gov (United States)

    Mitri, F. G.

    2016-09-01

    The Airy acoustical beam exhibits parabolic propagation and spatial acceleration, meaning that the propagation bending angle continuously increases before the beam trajectory reaches a critical angle where it decays after a propagation distance, without applying any external bending force. As such, it is of particular importance to investigate its properties from the standpoint of acoustical radiation force, spin torque, and particle dynamics theories, in the development of novel particle sorting techniques and acoustically mediated clearing systems. This work investigates these effects on a two-dimensional (2D) circular absorptive structure placed in the field of a nonparaxial Airy "acoustical-sheet" (i.e., finite beam in 2D), for potential applications in surface acoustic waves and acousto-fluidics. Based on the characteristics of the acoustic field, the beam is capable of manipulating the circular cylindrical fluid cross-section and guides it along a transverse or parabolic trajectory. This feature of Airy acoustical beams could lead to a unique characteristic in single-beam acoustical tweezers related to acoustical sieving, filtering, and removal of particles and cells from a section of a small channel. The analysis developed here is based on the description of the nonparaxial Airy beam using the angular spectrum decomposition of plane waves in close association with the partial-wave series expansion method in cylindrical coordinates. The numerical results demonstrate the ability of the nonparaxial Airy acoustical-sheet beam to pull, propel, or accelerate a particle along a parabolic trajectory, in addition to particle confinement in the transverse direction of wave propagation. Negative or positive radiation force and spin torque causing rotation in the clockwise or the anticlockwise direction can occur depending on the nondimensional parameter ka (where k is the wavenumber and a is the radius) and the location of the cylinder in the beam. Applications in

  13. Cutaneous lymphoid hyperplasia mimicking cutaneous lymphoma in a hyperthyroid cat

    OpenAIRE

    Snead, Elisabeth; Kerr, Moira; MacDonald, Valerie

    2013-01-01

    A 12-year-old neutered male domestic shorthair cat presented for chronic, localized, swelling and crusting of the left upper lip, weight loss, sporadic vomiting, and focal alopecia between the scapulae was diagnosed with hyperthyroidism and regional eosinophilic lymphadenitis. Treatment with methimazole exacerbated an underlying hypersensitivity disorder leading to marked generalized lymphadenopathy that histologically mimicked lymphoma.

  14. Giant Spermatocele Mimicking Hydrocele: A Case Report

    Directory of Open Access Journals (Sweden)

    Hsin-Chih Yeh

    2007-07-01

    Full Text Available Spermatoceles are usually asymptomatic and often found incidentally during physical examination. We report a case of giant spermatocele that mimicked a hydrocele. A 55-year-old man suffered from right scrotal enlargement for several years. As the heavy sensation and scrotal soreness worsened in recent months, he came to our outpatient clinic for help. Hydrocele was suspected due to transilluminating appearance of the scrotal content. Surgical exploration was arranged and a giant spermatocele was found. Total excision of the spermatocele was performed and the patient recovered well. The specimen was sent for pathology and spermatocele with spermatozoa was noted.

  15. Floating retained root lesion mimicking apical periodontitis.

    Science.gov (United States)

    Chung, Ming-Pang; Chen, Chih-Ping; Shieh, Yi-Shing

    2009-10-01

    A case of a retained root tip simulating apical periodontitis on radiographic examination is described. The retained root tip, originating from the left lower first molar, floated under the left lower second premolar apical region mimicking apical periodontitis. It appeared as an ill-defined periapical radiolucency containing a smaller radiodense mass on radiograph. The differential diagnosis included focal sclerosing osteomyelitis (condensing osteitis) and ossifying fibroma. Upon exicisional biopsy, a retained root associated with granulation tissue was found. After 1-year follow-up, the patient was asymptomatic and the periradicular lesion was healing. Meanwhile, the associated tooth showed a normal response to stimulation testing.

  16. Unusual presentation of chondroblastoma mimicking Trevor's disease

    Directory of Open Access Journals (Sweden)

    Y Karkhur

    2017-01-01

    Full Text Available Chondroblastoma is a benign bone tumor, represents 1%–2% of all primary bone tumors, typically seen in patients 10–25-year-old and more common in males. It occurs most frequently in the distal femur, proximal tibia, and proximal humerus. Soft tissue extension is extremely rare. Adjacent joints may develop effusions, but the tumor mass protruding into the joint has never been seen in case of chondroblastoma. We report a rare case of intra-articular chondroblastoma arising from proximal tibia in a 16-year-old boy and growing into the knee joint mimicking an intra-articular osteochondroma.

  17. Department of Cybernetic Acoustics

    Science.gov (United States)

    The development of the theory, instrumentation and applications of methods and systems for the measurement, analysis, processing and synthesis of acoustic signals within the audio frequency range, particularly of the speech signal and the vibro-acoustic signal emitted by technical and industrial equipments treated as noise and vibration sources was discussed. The research work, both theoretical and experimental, aims at applications in various branches of science, and medicine, such as: acoustical diagnostics and phoniatric rehabilitation of pathological and postoperative states of the speech organ; bilateral ""man-machine'' speech communication based on the analysis, recognition and synthesis of the speech signal; vibro-acoustical diagnostics and continuous monitoring of the state of machines, technical equipments and technological processes.

  18. Probability of cavitation for single ultrasound pulses applied to tissues and tissue-mimicking materials.

    Science.gov (United States)

    Maxwell, Adam D; Cain, Charles A; Hall, Timothy L; Fowlkes, J Brian; Xu, Zhen

    2013-03-01

    In this study, the negative pressure values at which inertial cavitation consistently occurs in response to a single, two-cycle, focused ultrasound pulse were measured in several media relevant to cavitation-based ultrasound therapy. The pulse was focused into a chamber containing one of the media, which included liquids, tissue-mimicking materials, and ex vivo canine tissue. Focal waveforms were measured by two separate techniques using a fiber-optic hydrophone. Inertial cavitation was identified by high-speed photography in optically transparent media and an acoustic passive cavitation detector. The probability of cavitation (P(cav)) for a single pulse as a function of peak negative pressure (p(-)) followed a sigmoid curve, with the probability approaching one when the pressure amplitude was sufficient. The statistical threshold (defined as P(cav) = 0.5) was between p(-) = 26 and 30 MPa in all samples with high water content but varied between p(-) = 13.7 and >36 MPa in other media. A model for radial cavitation bubble dynamics was employed to evaluate the behavior of cavitation nuclei at these pressure levels. A single bubble nucleus with an inertial cavitation threshold of p(-) = 28.2 megapascals was estimated to have a 2.5 nm radius in distilled water. These data may be valuable for cavitation-based ultrasound therapy to predict the likelihood of cavitation at various pressure levels and dimensions of cavitation-induced lesions in tissue. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Acoustic Liners for Turbine Engines

    Science.gov (United States)

    Jones, Michael G (Inventor); Grady, Joseph E (Inventor); Kiser, James D. (Inventor); Miller, Christopher (Inventor); Heidmann, James D. (Inventor)

    2016-01-01

    An improved acoustic liner for turbine engines is disclosed. The acoustic liner may include a straight cell section including a plurality of cells with straight chambers. The acoustic liner may also include a bent cell section including one or more cells that are bent to extend chamber length without increasing the overall height of the acoustic liner by the entire chamber length. In some cases, holes are placed between cell chambers in addition to bending the cells, or instead of bending the cells.

  20. Acoustic communication for Maya Autonomous Underwater Vehicle - performance evaluation of acoustic modem

    Digital Repository Service at National Institute of Oceanography (India)

    Afzulpurkar, S.; Maurya, P.; Navelkar, G.S.; Desa, E.S.; Mascarenhas, A.A.M.Q.; Dabholkar, N.A.; Madhan, R.; Prabhudesai, S.P.

    traffic. This necessitates monitoring the AUV status and data quality through an acoustic link which needs to perform reliably under such conditions, at long range. To address these situations partially, acoustic communication capability is planned...

  1. Acoustical and optical radiation pressures and the development of single beam acoustical tweezers

    OpenAIRE

    Thomas , Jean-Louis; Marchiano , Régis; Baresch , Diego

    2017-01-01

    International audience; Studies on radiation pressure in acoustics and optics have enriched one another and have a long common history. Acoustic radiation pressure is used for metrology, levitation, particle trapping and actuation. However, the dexterity and selectivity of single-beam optical tweezers are still to be matched with acoustical devices. Optical tweezers can trap, move and positioned micron size particles, biological samples or even atoms with subnanometer accuracy in three dimens...

  2. Early history of the different forms of neurofibromatosis from ancient Egypt to the British Empire and beyond: First descriptions, medical curiosities, misconceptions, landmarks, and the persons behind the syndromes.

    Science.gov (United States)

    Ruggieri, Martino; Praticò, Andrea D; Caltabiano, Rosario; Polizzi, Agata

    2018-03-01

    The earliest examples of neurofibromatosis (in this case type 1, NF1) can be traced in the Ebers Papyrus (Ancient Egypt, 1.500 B.C.), in a Hellenistic statuette (Smyrna, 323 B.C.), in the coinage of the Parthians kings (247 B.C.) and in some 13th century monks' drawings. These earlier examples are somewhat less well defined as compared to the most recent better defined reports credited as having NF1 including an Inca child mummy (1480-1650 AD), Ulisse Aldrovandi's homuncio ("Monstrorum Historia", 1592 A.D.) with mosaic NF1 or the illustrations seen in the 18th century "Buffon's Histoire Naturelle" and "Cruveilhier's Anatomie Pathologique du Corps Human". The first English language report on NF1 was made by Akenside in 1768 and the first systematic review by Robert William Smith in 1849, while Virchow's pupil, Friedrich Daniel von Recklinghausen, in 1882, was the first to understand the origin of skin tumors and to name them neurofibromas. The touching story of Joseph C. Merrick (the "Elephant man," (who had Proteus syndrome and not NF1), in 1884, played an important role in the later misconception of NF1, as did the novel by Vicotr Hugo on the hunchback Quasimodo. The studies by van der Hoeve (1921), Yakovlev and Guthrie (1931), and Van Bogaert (1935), categorized "von Recklinghausen's" neurofibromatosis among the phakomatoses and the neurocutaneous syndromes. The first known mention of an acoustic neuroma (at autopsy) is attributed to Eduard Sandifort (1777 AD) while John H. Wishart made the earliest autoptic description of neurofibromatosis type 2 (NF2), in 1822, in a 21-year-old man with bilateral acoustic neuromas, who manifested signs since his infancy (Wishart subtype NF2). Smith likely described the first case of schwannomatosis in 1849. Older, Virchow, von Recklinghausen, and Verocay first classified "neuromas" and Masson and Penfield first used the word "schwannoma" taking it from Theodore Schwann's works. In 1903 Henneberg and Koch described NF2 in detail

  3. Development of acoustic particle detector

    International Nuclear Information System (INIS)

    Matsuyama, Tadayoshi; Hinode, Fujio; Konno, Osamu

    1999-01-01

    To detect acoustic sign from electron, determination of acoustic radiation from high energy electron and detector were studied. When charge particles pass through medium, energy loss generates local expansion and contraction of medium and pressure compression wave. We need caustic element with 10 -5 Pa the minimum acoustic receive sensitivity and from 10 to 100 kHz frequency sensitivity characteristic. Elements were made by Low-Q materials, piezoelectric materials (PZT). Various sharp of elements were constructed and measured. 50 mm spherical element showed 38 m V/Pa, the best sensitivity. Our developed acoustic element could detect acoustic radiation generated by electron beam from accelerator. The wave sharp detected proved the same as bipolar wave, which was given theoretically. The pressure generated by beam was proportional to the energy loss E. 200 MeV electron beam existed about 95% particles on the incident axis. So that acoustic detector on the axis proved to detect sound wave generated on the beam axis. (S.Y.)

  4. Focusing of Acoustic Waves through Acoustic Materials with Subwavelength Structures

    KAUST Repository

    Xiao, Bingmu

    2013-05-01

    In this thesis, wave propagation through acoustic materials with subwavelength slits structures is studied. Guided by the findings, acoustic wave focusing is achieved with a specific material design. By using a parameter retrieving method, an effective medium theory for a slab with periodic subwavelength cut-through slits is successfully derived. The theory is based on eigenfunction solutions to the acoustic wave equation. Numerical simulations are implemented by the finite-difference time-domain (FDTD) method for the two-dimensional acoustic wave equation. The theory provides the effective impedance and refractive index functions for the equivalent medium, which can reproduce the transmission and reflection spectral responses of the original structure. I analytically and numerically investigate both the validity and limitations of the theory, and the influences of material and geometry on the effective spectral responses are studied. Results show that large contrasts in impedance and density are conditions that validate the effective medium theory, and this approximation displays a better accuracy for a thick slab with narrow slits in it. Based on the effective medium theory developed, a design of a at slab with a snake shaped" subwavelength structure is proposed as a means of achieving acoustic focusing. The property of focusing is demonstrated by FDTD simulations. Good agreement is observed between the proposed structure and the equivalent lens pre- dicted by the theory, which leads to robust broadband focusing by a thin at slab.

  5. Acoustic emission linear pulse holography

    Science.gov (United States)

    Collins, H.D.; Busse, L.J.; Lemon, D.K.

    1983-10-25

    This device relates to the concept of and means for performing Acoustic Emission Linear Pulse Holography, which combines the advantages of linear holographic imaging and Acoustic Emission into a single non-destructive inspection system. This unique system produces a chronological, linear holographic image of a flaw by utilizing the acoustic energy emitted during crack growth. The innovation is the concept of utilizing the crack-generated acoustic emission energy to generate a chronological series of images of a growing crack by applying linear, pulse holographic processing to the acoustic emission data. The process is implemented by placing on a structure an array of piezoelectric sensors (typically 16 or 32 of them) near the defect location. A reference sensor is placed between the defect and the array.

  6. Acoustic communication in plant-animal interactions.

    Science.gov (United States)

    Schöner, Michael G; Simon, Ralph; Schöner, Caroline R

    2016-08-01

    Acoustic communication is widespread and well-studied in animals but has been neglected in other organisms such as plants. However, there is growing evidence for acoustic communication in plant-animal interactions. While knowledge about active acoustic signalling in plants (i.e. active sound production) is still in its infancy, research on passive acoustic signalling (i.e. reflection of animal sounds) revealed that bat-dependent plants have adapted to the bats' echolocation systems by providing acoustic reflectors to attract their animal partners. Understanding the proximate mechanisms and ultimate causes of acoustic communication will shed light on an underestimated dimension of information transfer between plants and animals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Cartilage Delamination Flap Mimicking a Torn Medial Meniscus

    Directory of Open Access Journals (Sweden)

    Gan Zhi-Wei Jonathan

    2016-01-01

    Full Text Available We report a case of a chondral delamination lesion due to medial parapatellar plica friction syndrome involving the medial femoral condyle. This mimicked a torn medial meniscus in clinical and radiological presentation. Arthroscopy revealed a chondral delamination flap, which was debrided. Diagnosis of chondral lesions in the knee can be challenging. Clinical examination and MRI have good accuracy for diagnosis and should be used in tandem. Early diagnosis and treatment of chondral lesions are important to prevent progression to early osteoarthritis.

  8. Electrostatic ion acoustic waves

    International Nuclear Information System (INIS)

    Hasegawa, A.

    1983-01-01

    In this paper, certain aspects of plasma physics are illustrated through a study of electrostatic ion acoustic waves. The paper consists of three Sections. Section II deals with linear properties of the ion acoustic wave including derivation of the dispersions relation with the effect of Landau damping and of an ambient magnetic field. The section also introduces the excitation processes of the ion acoustic wave due to an electron drift or to a stimulated Brillouin scattering. The nonlinear properties are introduced in Section III and IV. In Section III, incoherent nonlinear effects such as quasilinear and mode-coupling saturations of the instability are discussed. The coherent nonlinear effects such as the generation of ion acoustic solitons, shocks and weak double layers are presented in Section IV. (Auth.)

  9. Highly Localized Acoustic Streaming and Size-Selective Submicrometer Particle Concentration Using High Frequency Microscale Focused Acoustic Fields.

    Science.gov (United States)

    Collins, David J; Ma, Zhichao; Ai, Ye

    2016-05-17

    Concentration and separation of particles and biological specimens are fundamental functions of micro/nanofluidic systems. Acoustic streaming is an effective and biocompatible way to create rapid microscale fluid motion and induce particle capture, though the >100 MHz frequencies required to directly generate acoustic body forces on the microscale have traditionally been difficult to generate and localize in a way that is amenable to efficient generation of streaming. Moreover, acoustic, hydrodynamic, and electrical forces as typically applied have difficulty manipulating specimens in the submicrometer regime. In this work, we introduce highly focused traveling surface acoustic waves (SAW) at high frequencies between 193 and 636 MHz for efficient and highly localized production of acoustic streaming vortices on microfluidic length scales. Concentration occurs via a novel mechanism, whereby the combined acoustic radiation and streaming field results in size-selective aggregation in fluid streamlines in the vicinity of a high-amplitude acoustic beam, as opposed to previous acoustic radiation induced particle concentration where objects typically migrate toward minimum pressure locations. Though the acoustic streaming is induced by a traveling wave, we are able to manipulate particles an order of magnitude smaller than possible using the traveling wave force alone. We experimentally and theoretically examine the range of particle sizes that can be captured in fluid streamlines using this technique, with rapid particle concentration demonstrated down to 300 nm diameters. We also demonstrate that locations of trapping and concentration are size-dependent, which is attributed to the combined effects of the acoustic streaming and acoustic forces.

  10. Coupled Acoustic-Mechanical Bandgaps

    DEFF Research Database (Denmark)

    Jensen, Jakob Søndergaard; Kook, Junghwan

    2016-01-01

    medium and the presence of acoustic resonances. It is demonstrated that corrugation of the plate structure can introduce bending wave bandgaps and bandgaps in the acoustic domain in overlapping and audible frequency ranges. This effect is preserved also when taking the physical coupling between the two...... domains into account. Additionally, the coupling is shown to introduce extra gaps in the band structure due to modal interaction and the appearance of a cut-on frequency for the fundamental acoustic mode....

  11. Atlantic Herring Acoustic Surveys

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NEFSC Advanced Sampling Technologies Research Group conducts annual fisheries acoustic surveys using state-of-the-art acoustic, midwater trawling, and underwater...

  12. Huge Dermatofibrosarcoma Protuberans Mimicking a Breast Malignant Tumor with Abscess

    Directory of Open Access Journals (Sweden)

    Han-Kun Chen

    2014-12-01

    Full Text Available Dermatofibrosarcoma protuberans (DFSP is an uncommon skin cancer that most commonly occurs on the trunk and extremities. DFSP of the breast has rarely been reported, and then is almost always of small size. We report a case of rapid-growing DFSP of the breast with abscess formation mimicking breast cancer, and also make a review of related literature.

  13. Transition section for acoustic waveguides

    International Nuclear Information System (INIS)

    Karplus, H.H.B.

    1975-01-01

    A means of facilitating the transmission of acoustic waves with minimal reflection between two regions having different specific acoustic impedances is described comprising a region exhibiting a constant product of cross-sectional area and specific acoustic impedance at each cross-sectional plane along the axis of the transition region. A variety of structures that exhibit this feature is disclosed, the preferred embodiment comprising a nested structure of doubly reentrant cones. This structure is useful for monitoring the operation of nuclear reactors in which random acoustic signals are generated in the course of operation

  14. Tunable coupled surface acoustic cavities

    Science.gov (United States)

    de Lima, M. M.; Santos, P. V.; Kosevich, Yu. A.; Cantarero, A.

    2012-06-01

    We demonstrate the electric tuning of the acoustic field in acoustic microcavities (MCs) defined by a periodic arrangement of metal stripes within a surface acoustic delay line on LiNbO3 substrate. Interferometric measurements show the enhancement of the acoustic field distribution within a single MC, the presence of a "bonding" and "anti-bonding" modes for two strongly coupled MCs, as well as the positive dispersion of the "mini-bands" formed by five coupled MCs. The frequency and amplitude of the resonances can be controlled by the potential applied to the metal stripes.

  15. Tethys Acoustic Metadata Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Tethys database houses the metadata associated with the acoustic data collection efforts by the Passive Acoustic Group. These metadata include dates, locations...

  16. Addison's Disease Mimicking as Acute Pancreatitis: A Case Report.

    Science.gov (United States)

    Chaudhuri, Sayani; Rao, Karthik N; Patil, Navin; Ommurugan, Balaji; Varghese, George

    2017-04-01

    Over past two decades there has been significant improvement in medical field in elucidating the underlying pathophysiology and genetics of Addison's disease. Adrenal insufficiency (Addison's disease) is a rare disease with an incidence of 0.8/100,000 cases. The diagnosis may be delayed if the clinical presentation mimics a gastrointestinal disorder or psychiatric illness. We report a case of Addison's disease presenting as acute pain in abdomen mimicking clinical presentation of acute pancreatitis.

  17. A case of gallbladder mass: Malakoplakia (The tumor mimicker

    Directory of Open Access Journals (Sweden)

    Kanwaljeet Singh

    2017-01-01

    Full Text Available Diagnosis of malakoplakia presenting as gall bladder mass is a diagnostic dilemma faced by pathologists, radiologists, and surgeons. Malakoplakia is a rare inflammatory disorder and tumor mimicker usually occurring in the urinary tract, may occasionally be found in gall bladder. Here, we present a rare case, presenting as gall bladder mass in a known case of gallstone disease, clinically suspected as carcinoma and later turned out to be malakoplakia in gall bladder.

  18. Aerosol behaviour in an acoustic field

    International Nuclear Information System (INIS)

    Malherbe, C.

    1985-01-01

    The average size of an aerosol submitted to acoustic waves is increased. This results from coagulation of the finest particles on the largest ones. The mechanisms responsible for acoustic agglomeration are mentioned. An experimental apparatus was developed in order to control the evolution of aerosol distribution in an acoustic field. Important deposition on the walls of the agglomeration chamber was observed as a consequence of the acoustically induced turbulent flow. Finally, a dimensionless relationship was established between deposition rates and particle diameters as a function of experimental parameters (aeraulic and acoustic conditions, etc...) [fr

  19. Broadband unidirectional acoustic cloak based on phase gradient metasurfaces with two flat acoustic lenses

    Science.gov (United States)

    Wang, Xiao-Peng; Wan, Le-Le; Chen, Tian-Ning; Song, Ai-Ling; Wang, Fang

    2016-07-01

    Narrow bandwidth and bulky configuration are the main obstacles for the realization and application of invisible cloaks. In this paper, we present an effective method to achieve broadband and thin acoustic cloak by using an acoustic metasurface (AMS). In order to realize this cloak, we use slitted unit cells to design the AMS due to the advantage of less energy loss, broad operation bandwidth, and subwavelength thickness. According to the hyperboloidal phase profile along the AMS, the incident plane waves can be focused at a designed focal spot by the flat lens. Furthermore, broadband acoustic cloak is obtained by combining two identical flat lenses. The incident plane waves are focused at the center point in between of the two lenses by passing through one lens, and then recovered by passing through the other one. However, they cannot reach the cloaked regions in between of the two lenses. The simulation results can verify the non-detectability effect of the acoustic cloak. Our study results provide an available and simple approach to experimentally achieve the acoustic cloak, which can be used in acoustic non-detectability for large objects.

  20. Determination of the viscous acoustic field for liquid drop positioning/forcing in an acoustic levitation chamber in microgravity

    Science.gov (United States)

    Lyell, Margaret J.

    1992-01-01

    The development of acoustic levitation systems has provided a technology with which to undertake droplet studies as well as do containerless processing experiments in a microgravity environment. Acoustic levitation chambers utilize radiation pressure forces to position/manipulate the drop. Oscillations can be induced via frequency modulation of the acoustic wave, with the modulated acoustic radiation vector acting as the driving force. To account for tangential as well as radial forcing, it is necessary that the viscous effects be included in the acoustic field. The method of composite expansions is employed in the determination of the acoustic field with viscous effects.

  1. Novel Fiber-Optic Ring Acoustic Emission Sensor.

    Science.gov (United States)

    Wei, Peng; Han, Xiaole; Xia, Dong; Liu, Taolin; Lang, Hao

    2018-01-13

    Acoustic emission technology has been applied to many fields for many years. However, the conventional piezoelectric acoustic emission sensors cannot be used in extreme environments, such as those with heavy electromagnetic interference, high pressure, or strong corrosion. In this paper, a novel fiber-optic ring acoustic emission sensor is proposed. The sensor exhibits high sensitivity, anti-electromagnetic interference, and corrosion resistance. First, the principle of a novel fiber-optic ring sensor is introduced. Different from piezoelectric and other fiber acoustic emission sensors, this novel sensor includes both a sensing skeleton and a sensing fiber. Second, a heterodyne interferometric demodulating method is presented. In addition, a fiber-optic ring sensor acoustic emission system is built based on this method. Finally, fiber-optic ring acoustic emission experiments are performed. The novel fiber-optic ring sensor is glued onto the surface of an aluminum plate. The 150 kHz standard continuous sinusoidal signals and broken lead signals are successfully detected by the novel fiber-optic ring acoustic emission sensor. In addition, comparison to the piezoelectric acoustic emission sensor is performed, which shows the availability and reliability of the novel fiber-optic ring acoustic emission sensor. In the future, this novel fiber-optic ring acoustic emission sensor will provide a new route to acoustic emission detection in harsh environments.

  2. Acoustic logic gates and Boolean operation based on self-collimating acoustic beams

    International Nuclear Information System (INIS)

    Zhang, Ting; Xu, Jian-yi; Cheng, Ying; Liu, Xiao-jun; Guo, Jian-zhong

    2015-01-01

    The reveal of self-collimation effect in two-dimensional (2D) photonic or acoustic crystals has opened up possibilities for signal manipulation. In this paper, we have proposed acoustic logic gates based on the linear interference of self-collimated beams in 2D sonic crystals (SCs) with line-defects. The line defects on the diagonal of the 2D square SCs are actually functioning as a 3 dB splitter. By adjusting the phase difference between two input signals, the basic Boolean logic functions such as XOR, OR, AND, and NOT are achieved both theoretically and experimentally. Due to the non-diffracting property of self-collimation beams, more complex Boolean logic and algorithms such as NAND, NOR, and XNOR can be realized by cascading the basic logic gates. The achievement of acoustic logic gates and Boolean operation provides a promising approach for acoustic signal computing and manipulations

  3. Nephrogenic rests mimicking Wilms' tumor on CT

    International Nuclear Information System (INIS)

    Subhas, Naveen; Siegelman, Stanley S.; Argani, Pedram; Gearhart, John P.

    2004-01-01

    Nephrogenic rests (NR) are persistent benign remnants of embryonic renal tissue. A small percentage of these may develop into Wilms' tumor (WT). Radiologic imaging is relied upon to differentiate between these entities, with the hallmark of malignant transformation being growth on serial imaging studies. There is, however, considerable overlap in their imaging characteristics. The authors present a case of two biopsy-proven NR in a 2-year-old girl with sporadic aniridia that were indistinguishable from WT on initial radiologic studies. One of the NR grew on serial imaging studies mimicking a WT, but after resection was confirmed to be a benign hyperplastic NR on pathologic examination. (orig.)

  4. Use of acoustic field in gas cleaning

    International Nuclear Information System (INIS)

    Boulaud, D.; Madelaine, G.; Malherbe, C.

    1985-01-01

    The use of acoustic field in gas cleaning can be done in two ways: the first is the conditioning of an aerosol by acoustic agglomeration before filtration by conventional methods (cyclones, granular beds, etc.), the second is the collection efficiency improvement of granular bed filters exposed to an acoustic field. In a first part, experimental results are given on the acoustic agglomeration of a polydisperse aerosol of mass concentration between 0.5 and 1 g/m 3 . An important effect of wall precipitation of particles is described and deposition velocity due to the presence of an acoustic field are measured as a function of particle diameter, sound pressure level and acoustic frequency. A dimensionless relationship between the deposition velocity and particle relaxation time is established for these results. At the end of this part energetic criteria for the use of acoustic agglomeration in a gas cleaning train is given. In a second part, experimental results are given to the influence of acoustic field on the collection efficiency of monodispersed aerosols ranging from 0.1 to 1 μm. For these both uses of acoustic field in industrial gas cleaning the different alternatives for the acoustic field generation are discussed

  5. Sinusoidal Representation of Acoustic Signals

    Science.gov (United States)

    Honda, Masaaki

    Sinusoidal representation of acoustic signals has been an important tool in speech and music processing like signal analysis, synthesis and time scale or pitch modifications. It can be applicable to arbitrary signals, which is an important advantage over other signal representations like physical modeling of acoustic signals. In sinusoidal representation, acoustic signals are composed as sums of sinusoid (sine wave) with different amplitudes, frequencies and phases, which is based on the timedependent short-time Fourier transform (STFT). This article describes the principles of acoustic signal analysis/synthesis based on a sinusoid representation with focus on sine waves with rapidly varying frequency.

  6. Acoustic loading effects on oscillating rod bundles

    International Nuclear Information System (INIS)

    Lin, W.H.

    1980-01-01

    An analytical study of the interaction between an infinite acoustic medium and a cluster of circular rods is described. The acoustic field due to oscillating rods and the acoustic loading on the rods are first solved in a closed form. The acoustic loading is then used as a forcing function for rod responses, and the acousto-elastic couplings are solved simultaneously. Numerical examples are presented for several cases to illustrate the effects of various system parameters on the acoustic reaction force coefficients. The effect of the acoustic loading on the coupled eigenfrequencies are discussed

  7. ISAT: The mega-fauna acoustic tracking system

    KAUST Repository

    De la Torre, Pedro; Smith, Egan Lloyd; Sancheti, Ajay; Salama, Khaled N.; Berumen, Michael L.

    2013-01-01

    The acoustic tracking module of the Integrated Satellite and Acoustic Telemetry (iSAT) system is discussed in detail. iSAT is capable of detecting the relative direction of an acoustic source by measuring the order of arrival (OOA) of the acoustic

  8. Pleural pneumatocoeles mimicking congenital cystic adenomatoid malformation of the lung. A case report

    International Nuclear Information System (INIS)

    Aurora, P.; McHugh, K.

    1998-01-01

    We present the plain radiographic and CT appearances of large intrapleural pneumatocoeles in a 13-week-old infant, resulting in compression atelectasis of the left upper and lower lobes, and mimicking congenital cystic adenomatoid malformation. (orig.)

  9. Novel Fiber-Optic Ring Acoustic Emission Sensor

    Directory of Open Access Journals (Sweden)

    Peng Wei

    2018-01-01

    Full Text Available Acoustic emission technology has been applied to many fields for many years. However, the conventional piezoelectric acoustic emission sensors cannot be used in extreme environments, such as those with heavy electromagnetic interference, high pressure, or strong corrosion. In this paper, a novel fiber-optic ring acoustic emission sensor is proposed. The sensor exhibits high sensitivity, anti-electromagnetic interference, and corrosion resistance. First, the principle of a novel fiber-optic ring sensor is introduced. Different from piezoelectric and other fiber acoustic emission sensors, this novel sensor includes both a sensing skeleton and a sensing fiber. Second, a heterodyne interferometric demodulating method is presented. In addition, a fiber-optic ring sensor acoustic emission system is built based on this method. Finally, fiber-optic ring acoustic emission experiments are performed. The novel fiber-optic ring sensor is glued onto the surface of an aluminum plate. The 150 kHz standard continuous sinusoidal signals and broken lead signals are successfully detected by the novel fiber-optic ring acoustic emission sensor. In addition, comparison to the piezoelectric acoustic emission sensor is performed, which shows the availability and reliability of the novel fiber-optic ring acoustic emission sensor. In the future, this novel fiber-optic ring acoustic emission sensor will provide a new route to acoustic emission detection in harsh environments.

  10. Density-near-zero using the acoustically induced transparency of a Fano acoustic resonator

    KAUST Repository

    Elayouch, A.; Addouche, M.; Farhat, Mohamed; El-Amin, Mohamed; Bagci, Hakan; Khelif, A.

    2017-01-01

    We report experimental results of near-zero mass density involving an acoustic metamaterial supporting Fano resonance. For this, we designed and fabricated an acoustic resonator with two closely coupled modes and measured its transmission properties

  11. Controlling Sample Rotation in Acoustic Levitation

    Science.gov (United States)

    Barmatz, M. B.; Stoneburner, J. D.

    1985-01-01

    Rotation of acoustically levitated object stopped or controlled according to phase-shift monitoring and control concept. Principle applies to square-cross-section levitation chamber with two perpendicular acoustic drivers operating at same frequency. Phase difference between X and Y acoustic excitation measured at one corner by measuring variation of acoustic amplitude sensed by microphone. Phase of driver adjusted to value that produces no rotation or controlled rotation of levitated object.

  12. Waveform-preserved unidirectional acoustic transmission based on impedance-matched acoustic metasurface and phononic crystal

    Science.gov (United States)

    Song, Ai-Ling; Chen, Tian-Ning; Wang, Xiao-Peng; Wan, Le-Le

    2016-08-01

    The waveform distortion happens in most of the unidirectional acoustic transmission (UAT) devices proposed before. In this paper, a novel type of waveform-preserved UAT device composed of an impedance-matched acoustic metasurface (AMS) and a phononic crystal (PC) structure is proposed and numerically investigated. The acoustic pressure field distributions and transmittance are calculated by using the finite element method. The subwavelength AMS that can modulate the wavefront of the transmitted wave at will is designed and the band structure of the PC structure is calculated and analyzed. The sound pressure field distributions demonstrate that the unidirectional acoustic transmission can be realized by the proposed UAT device without changing the waveforms of the output waves, which is the distinctive feature compared with the previous UAT devices. The physical mechanism of the unidirectional acoustic transmission is discussed by analyzing the refraction angle changes and partial band gap map. The calculated transmission spectra show that the UAT device is valid within a relatively broad frequency range. The simulation results agree well with the theoretical predictions. The proposed UAT device provides a good reference for designing waveform-preserved UAT devices and has potential applications in many fields, such as medical ultrasound, acoustic rectifiers, and noise insulation.

  13. Acoustic spin pumping in magnetoelectric bulk acoustic wave resonator

    Directory of Open Access Journals (Sweden)

    N. I. Polzikova

    2016-05-01

    Full Text Available We present the generation and detection of spin currents by using magnetoelastic resonance excitation in a magnetoelectric composite high overtone bulk acoustic wave (BAW resonator (HBAR formed by a Al-ZnO-Al-GGG-YIG-Pt structure. Transversal BAW drives magnetization oscillations in YIG film at a given resonant magnetic field, and the resonant magneto-elastic coupling establishes the spin-current generation at the Pt/YIG interface. Due to the inverse spin Hall effect (ISHE this BAW-driven spin current is converted to a dc voltage in the Pt layer. The dependence of the measured voltage both on magnetic field and frequency has a resonant character. The voltage is determined by the acoustic power in HBAR and changes its sign upon magnetic field reversal. We compare the experimentally observed amplitudes of the ISHE electrical field achieved by our method and other approaches to spin current generation that use surface acoustic waves and microwave resonators for ferromagnetic resonance excitation, with the theoretically expected values.

  14. Acoustic spin pumping in magnetoelectric bulk acoustic wave resonator

    Energy Technology Data Exchange (ETDEWEB)

    Polzikova, N. I., E-mail: polz@cplire.ru; Alekseev, S. G.; Pyataikin, I. I.; Kotelyanskii, I. M.; Luzanov, V. A.; Orlov, A. P. [Kotel’nikov Institute of Radio Engineering and Electronics of Russian Academy of Sciences, Mokhovaya 11, building 7, Moscow, 125009 (Russian Federation)

    2016-05-15

    We present the generation and detection of spin currents by using magnetoelastic resonance excitation in a magnetoelectric composite high overtone bulk acoustic wave (BAW) resonator (HBAR) formed by a Al-ZnO-Al-GGG-YIG-Pt structure. Transversal BAW drives magnetization oscillations in YIG film at a given resonant magnetic field, and the resonant magneto-elastic coupling establishes the spin-current generation at the Pt/YIG interface. Due to the inverse spin Hall effect (ISHE) this BAW-driven spin current is converted to a dc voltage in the Pt layer. The dependence of the measured voltage both on magnetic field and frequency has a resonant character. The voltage is determined by the acoustic power in HBAR and changes its sign upon magnetic field reversal. We compare the experimentally observed amplitudes of the ISHE electrical field achieved by our method and other approaches to spin current generation that use surface acoustic waves and microwave resonators for ferromagnetic resonance excitation, with the theoretically expected values.

  15. Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

    Science.gov (United States)

    Vargas, Magda B.; Counter, Douglas

    2011-01-01

    Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

  16. Low frequency acoustic properties of bilayer membrane acoustic metamaterial with magnetic oscillator

    Directory of Open Access Journals (Sweden)

    Nansha Gao

    2017-07-01

    Full Text Available A bilayer membrane acoustic metamaterial was proposed to overcome the influence of the mass law on traditional acoustic materials and obtain a lightweight thin-layer structure that can effectively isolate low frequency noise. The finite element analysis (FEA results agree well with the experimental results. It is proved that the sound transmission losses (STLs of the proposed structures are higher than those of same surface density acoustic materials. The introduction of the magnetic mass block is different from the traditional design method, in which only a passive mass block is fixed on the membrane. The magnetic force will cause tension in the membrane, increase membrane prestress, and improve overall structural stiffness. The effects of the geometry size on the STLs are discussed in detail. The kind of method presented in this paper can provide a new means for engineering noise control. Keywords: Bilayer membrane acoustic metamaterial, Low frequency sound insulation, Sound transmission loss, Magnet oscillator

  17. Hidden acoustic information revealed by intentional nonlinearity

    Science.gov (United States)

    Dowling, David R.

    2017-11-01

    Acoustic waves are omnipresent in modern life and are well described by the linearized equations of fluid dynamics. Once generated, acoustic waves carry and collect information about their source and the environment through which they propagate, respectively, and this information may be retrieved by analyzing recordings of these waves. Because of this, acoustics is the primary means for observation, surveillance, reconnaissance, and remote sensing in otherwise opaque environments, such as the Earth's oceans and crust, and the interior of the human body. For such information-retrieval tasks, acoustic fields are nearly always interrogated within their recorded frequency range or bandwidth. However, this frequency-range restriction is not general; acoustic fields may also carry (hidden) information at frequencies outside their bandwidth. Although such a claim may seem counter intuitive, hidden acoustic-field information can be revealed by re-introducing a marquee trait of fluid dynamics: nonlinearity. In particular, an intentional quadratic nonlinearity - a form of intra-signal heterodyning - can be used to obtain acoustic field information at frequencies outside a recorded acoustic field's bandwidth. This quadratic nonlinearity enables a variety of acoustic remote sensing applications that were long thought to be impossible. In particular, it allows the detrimental effects of sparse recordings and random scattering to be suppressed when the original acoustic field has sufficient bandwidth. In this presentation, the topic is developed heuristically, with a just brief exposition of the relevant mathematics. Hidden acoustic field information is then revealed from simulated and measured acoustic fields in simple and complicated acoustic environments involving frequencies from a few Hertz to more than 100 kHz, and propagation distances from tens of centimeters to hundreds of kilometers. Sponsored by ONR, NAVSEA, and NSF.

  18. Solid-phase synthesis of an apoptosis-inducing tetrapeptide mimicking the Smac protein

    DEFF Research Database (Denmark)

    Le Quement, Sebastian Thordal; Ishøy, Mette; Petersen, Mette Terp

    2011-01-01

    An approach for the solid-phase synthesis of apoptosis-inducing Smac peptidomimetics is presented. Using a Rink linker strategy, tetrapeptides mimicking the N-4-terminal residue of the Smac protein [(N-Me)AVPF sequence] were synthesized on PEGA resin in excellent purities and yields. Following two...

  19. Guided acoustic wave inspection system

    Science.gov (United States)

    Chinn, Diane J.

    2004-10-05

    A system for inspecting a conduit for undesirable characteristics. A transducer system induces guided acoustic waves onto said conduit. The transducer system detects the undesirable characteristics of the conduit by receiving guided acoustic waves that contain information about the undesirable characteristics. The conduit has at least two sides and the transducer system utilizes flexural modes of propagation to provide inspection using access from only the one side of the conduit. Cracking is detected with pulse-echo testing using one transducer to both send and receive the guided acoustic waves. Thinning is detected in through-transmission testing where one transducer sends and another transducer receives the guided acoustic waves.

  20. Nonlinear frequency shift of a coherent dust-acoustic wave in the presence of dust-acoustic turbulence

    International Nuclear Information System (INIS)

    Yi Sumin; Ryu, C.-M.; Yoon, Peter H.

    2003-01-01

    The nonlinear frequency shift of a low-frequency, coherent dust-acoustic wave in the presence of higher frequency dust-acoustic turbulence is investigated in the framework of weak turbulence theory. It is found that the frequency shift of the dust-acoustic wave in an unmagnetized dusty plasma is always positive irrespective of the propagation direction of the coherent wave. It is also found that turbulent waves propagating in the same direction as the coherent wave are shown to give rise to a much higher frequency shift than the opposite case. Finally, it is shown that the nonlinear frequency shift of a dust-acoustic wave is more pronounced than in the case of the customary ion-acoustic waves in fully ionized plasmas

  1. Subaortic membrane mimicking hypertrophic cardiomyopathy.

    Science.gov (United States)

    Anderson, Mark Joseph; Arruda-Olson, Adelaide; Gersh, Bernard; Geske, Jeffrey

    2015-11-04

    A 34-year-old man was referred for progressive angina and exertional dyspnoea refractory to medical therapy, with a presumptive diagnosis of hypertrophic cardiomyopathy (HCM). Transthoracic echocardiography (TTE) revealed asymmetric septal hypertrophy without systolic anterior motion of the mitral valve leaflet and with no dynamic left ventricular outflow tract (LVOT) obstruction. However, the LVOT velocity was elevated at rest as well as with provocation, without the characteristic late peaking obstruction seen in HCM. Focused TTE to evaluate for suspected fixed obstruction demonstrated a subaortic membrane 2.2 cm below the aortic valve. Coronary CT angiography confirmed the presence of the subaortic membrane and was negative for concomitant coronary artery disease. Surgical resection of the subaortic membrane and septal myectomy resulted in significant symptomatic relief and lower LVOT velocities on postoperative TTE. This case reminds the clinician to carefully evaluate for alternative causes of LVOT obstruction, especially subaortic membrane, as a cause of symptoms mimicking HCM. 2015 BMJ Publishing Group Ltd.

  2. Odontogenic Keratocyst Mimicking Paradental Cyst

    Directory of Open Access Journals (Sweden)

    Andrea Enrico Borgonovo

    2014-01-01

    Full Text Available Objective. The aim of this paper is to present an uncommon clinical and radiographic aspect of odontogenic keratocyst (OKC mimicking paradental cyst. Methods. A 32-year-old female patient showed a well-delimited radiolucent lesion connected with the root of the left third molar with close anatomical relationship with the mandibular canal. The clinical, radiographic, and anamnestic features lead us to diagnose a paradental cyst that was treated by enucleation after extraction of the partially impacted tooth. Results. Histological analysis showed typical histological features of PKC such as the presence of a lining of stratified squamous epithelium with a well-defined basal layer of palisading columnar of cuboidal cells. Conclusion. Initial X-ray analysis and the position of the lesion related to the third mandibular tooth caused us to mistakenly diagnose a paradental cyst. We were only able to identify the cyst as an PKC rather than a paradental cyst after histological analysis.

  3. Humanlike Robots - Synthetically Mimicking Humans

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2012-01-01

    Nature inspired many inventions and the field of technology that is based on the mimicking or inspiration of nature is widely known as Biomimetics and it is increasingly leading to many new capabilities. There are numerous examples of biomimetic successes including the copying of fins for swimming, and the inspiration of the insects and birds flight. More and more commercial implementations of biomimetics are appearing and behaving lifelike and applications are emerging that are important to our daily life. Making humanlike robots is the ultimate challenge to biomimetics and, for many years, it was considered science fiction, but such robots are becoming an engineering reality. Advances in producing such robot are allowing them to perform impressive functions and tasks. The development of such robots involves addressing many challenges and is raising concerns that are related to fear of their application implications and potential ethical issues. In this paper, the state-of-the-art of humanlike robots, potential applications and challenges will be reviewed.

  4. The deep sea Acoustic Detection system AMADEUS

    International Nuclear Information System (INIS)

    Naumann, Christopher Lindsay

    2008-01-01

    As a part of the ANTARES neutrino telescope, the AMADEUS (ANTARES Modules for Acoustic Detection Under the Sea) system is an array of acoustical sensors designed to investigate the possibilities of acoustic detection of ultra-high energy neutrinos in the deep sea. The complete system will comprise a total of 36 acoustic sensors in six clusters on two of the ANTARES detector lines. With an inter-sensor spacing of about one metre inside the clusters and between 15 and 340 metres between the different clusters, it will cover a wide range of distances as will as provide a considerable lever arm for point source triangulation. Three of these clusters have already been deployed in 2007 and have been in operation since, currently yielding around 2GB of acoustic data per day. The remaining three clusters are scheduled to be deployed in May 2008 together with the final ANTARES detector line. Apart from proving the feasibility of operating an acoustic detection system in the deep sea, the main aim of this project is an in-depth survey of both the acoustic properties of the sea water and the acoustic background present at the detector site. It will also serve as a platform for the development and refinement of triggering, filtering and reconstruction algorithms for acoustic particle detection. In this presentation, a description of the acoustic sensor and read-out system is given, together with examples for the reconstruction and evaluation of the acoustic data.

  5. De-Dopplerization of Acoustic Measurements

    Science.gov (United States)

    2017-08-10

    accurate measurement of aircraft location to resample the time signal to account for the compression and expansion of acoustic wavefronts. Correcting...AFRL-RH-WP-TR-2017-0043 DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS Frank Mobley, PhD 711 HPW/RHCB Wright-Patterson AFB OH...TITLE AND SUBTITLE DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  6. Acoustic emission

    International Nuclear Information System (INIS)

    Straus, A.; Lopez Pumarega, M.I.; Di Gaetano, J.O.; D'Atellis, C.E.; Ruzzante, J.E.

    1990-01-01

    This paper is related to our activities on acoustic emission (A.E.). The work is made with different materials: metals and fibre reinforced plastics. At present, acoustic emission transducers are being developed for low and high temperature. A test to detect electrical discharges in electrical transformers was performed. Our experience in industrial tests to detect cracks or failures in tanks or tubes is also described. The use of A.E. for leak detection is considered. Works on pattern recognition of A.E. signals are also being performed. (Author)

  7. Theory and modeling of cylindrical thermo-acoustic transduction

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Lihong, E-mail: lhtong@ecjtu.edu.cn [School of Civil Engineering and Architecture, East China Jiaotong University, Nanchang, Jiangxi (China); Lim, C.W. [Department of Architecture and Civil Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR (China); Zhao, Xiushao; Geng, Daxing [School of Civil Engineering and Architecture, East China Jiaotong University, Nanchang, Jiangxi (China)

    2016-06-03

    Models both for solid and thinfilm-solid cylindrical thermo-acoustic transductions are proposed and the corresponding acoustic pressure solutions are obtained. The acoustic pressure for an individual carbon nanotube (CNT) as a function of input power is investigated analytically and it is verified by comparing with the published experimental data. Further numerical analysis on the acoustic pressure response and characteristics for varying input frequency and distance are also examined both for solid and thinfilm-solid cylindrical thermo-acoustic transductions. Through detailed theoretical and numerical studies on the acoustic pressure solution for thinfilm-solid cylindrical transduction, it is concluded that a solid with smaller thermal conductivity favors to improve the acoustic performance. In general, the proposed models are applicable to a variety of cylindrical thermo-acoustic devices performing in different gaseous media. - Highlights: • Theory and modeling both for solid and thinfilm-solid cylindrical thermo-acoustic transductions are proposed. • The modeling is verified by comparing with the published experimental data. • Acoustic response characteristics of cylindrical thermo-acoustic transductions are predicted by the proposed model.

  8. Acoustic constituents of prosodic typology

    Science.gov (United States)

    Komatsu, Masahiko

    Different languages sound different, and considerable part of it derives from the typological difference of prosody. Although such difference is often referred to as lexical accent types (stress accent, pitch accent, and tone; e.g. English, Japanese, and Chinese respectively) and rhythm types (stress-, syllable-, and mora-timed rhythms; e.g. English, Spanish, and Japanese respectively), it is unclear whether these types are determined in terms of acoustic properties, The thesis intends to provide a potential basis for the description of prosody in terms of acoustics. It argues for the hypothesis that the source component of the source-filter model (acoustic features) approximately corresponds to prosody (linguistic features) through several experimental-phonetic studies. The study consists of four parts. (1) Preliminary experiment: Perceptual language identification tests were performed using English and Japanese speech samples whose frequency spectral information (i.e. non-source component) is heavily reduced. The results indicated that humans can discriminate languages with such signals. (2) Discussion on the linguistic information that the source component contains: This part constitutes the foundation of the argument of the thesis. Perception tests of consonants with the source signal indicated that the source component carries the information on broad categories of phonemes that contributes to the creation of rhythm. (3) Acoustic analysis: The speech samples of Chinese, English, Japanese, and Spanish, differing in prosodic types, were analyzed. These languages showed difference in acoustic characteristics of the source component. (4) Perceptual experiment: A language identification test for the above four languages was performed using the source signal with its acoustic features parameterized. It revealed that humans can discriminate prosodic types solely with the source features and that the discrimination is easier as acoustic information increases. The

  9. Acoustics Critical Readiness Review

    Science.gov (United States)

    Ballard, Kenny

    2010-01-01

    This presentation reviews the status of the acoustic equipment from the medical operations perspective. Included is information about the acoustic dosimeters, sound level meter, and headphones that are planned for use while on orbit. Finally there is information about on-orbit hearing assessments.

  10. Acoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW).

    Science.gov (United States)

    Shi, Jinjie; Ahmed, Daniel; Mao, Xiaole; Lin, Sz-Chin Steven; Lawit, Aitan; Huang, Tony Jun

    2009-10-21

    Here we present an active patterning technique named "acoustic tweezers" that utilizes standing surface acoustic wave (SSAW) to manipulate and pattern cells and microparticles. This technique is capable of patterning cells and microparticles regardless of shape, size, charge or polarity. Its power intensity, approximately 5x10(5) times lower than that of optical tweezers, compares favorably with those of other active patterning methods. Flow cytometry studies have revealed it to be non-invasive. The aforementioned advantages, along with this technique's simple design and ability to be miniaturized, render the "acoustic tweezers" technique a promising tool for various applications in biology, chemistry, engineering, and materials science.

  11. Acoustic communication in plant–animal interactions

    NARCIS (Netherlands)

    Schöner, M.G.; Simon, R.; Schöner, C.R.

    2016-01-01

    Acoustic communication is widespread and well-studied in animals but has been neglected in other organisms such as plants. However, there is growing evidence for acoustic communication in plant–animal interactions. While knowledge about active acoustic signalling in plants (i.e. active sound

  12. A low frequency acoustic insulator by using the acoustic metasurface to a Helmholtz resonator

    Science.gov (United States)

    Zhao, Xiang; Cai, Li; Yu, Dianlong; Lu, Zhimiao; Wen, Jihong

    2017-06-01

    Acoustic metasurfaces (AMSs) are able to manipulate wavefronts at an anomalous angle through a subwavelength layer. Their application provide a new way to control sound waves in addition to traditional materials. In this work, we introduced the AMS into the design of a Helmholtz resonator (HR) and studied the acoustic transmission through the modified HR in a pipe with one branch. The variation of sound insulation capacity with the phase gradient of the AMS was studied, and the results show that the AMS can remarkably lower the frequency band of the sound insulation without increasing the size. Our investigation provides a new degree of freedom for acoustic control with a Helmholtz resonator, which is of great significance in acoustic metasurface theory and sound insulation design.

  13. Applied acoustics concepts, absorbers, and silencers for acoustical comfort and noise control alternative solutions, innovative tools, practical examples

    CERN Document Server

    Fuchs, Helmut V

    2013-01-01

    The author gives a comprehensive overview of materials and components for noise control and acoustical comfort. Sound absorbers must meet acoustical and architectural requirements, which fibrous or porous material alone can meet. Basics and applications are demonstrated, with representative examples for spatial acoustics, free-field test facilities and canal linings. Acoustic engineers and construction professionals will find some new basic concepts and tools for developments in order to improve acoustical comfort. Interference absorbers, active resonators and micro-perforated absorbers of different materials and designs complete the list of applications.

  14. Acoustic effects of single electrostatic discharges

    International Nuclear Information System (INIS)

    Orzech, Łukasz

    2015-01-01

    Electric discharges, depending on their character, can emit different types of energy, resulting in different effects. Single electrostatic discharges besides generation of electromagnetic pulses are also the source of N acoustic waves. Their specified parameters depending on amount of discharging charge enable determination of value of released charge in a function of acoustic descriptor (e.g. acoustic pressure). Presented approach is the basics of acoustic method for measurement of single electrostatic discharges, enabling direct and contactless measurement of value of charge released during ESD. Method for measurement of acoustic effect of impact of a single electrostatic discharge on the environment in a form of pressure shock wave and examples of acoustic descriptors in a form of equation Q=f(p a ) are described. The properties of measuring system as well as the results of regression static analyses used to determine the described relationships are analysed in details. (paper)

  15. Anal acoustic reflectometry

    DEFF Research Database (Denmark)

    Mitchell, Peter J; Klarskov, Niels; Telford, Karen J

    2011-01-01

    Anal acoustic reflectometry is a new technique of assessing anal sphincter function. Five new variables reflecting anal canal function are measured: the opening and closing pressure, the opening and closing elastance, and hysteresis.......Anal acoustic reflectometry is a new technique of assessing anal sphincter function. Five new variables reflecting anal canal function are measured: the opening and closing pressure, the opening and closing elastance, and hysteresis....

  16. Acoustic analysis of a piping system

    International Nuclear Information System (INIS)

    Misra, A.S.; Vijay, D.K.

    1996-01-01

    Acoustic pulsations in the Darlington Nuclear Generating Station, a 881 MW CANDU, primary heat transport piping system caused fuel bundle failures under short term operations. The problem was successfully analyzed using the steady-state acoustic analysis capability of the ABAQUS program. This paper describes in general, modelling of low amplitude acoustic pulsations in a liquid filled piping system using ABAQUS. The paper gives techniques for estimating the acoustic medium properties--bulk modulus, fluid density and acoustic damping--and modelling fluid-structure interactions at orifices and elbows. The formulations and techniques developed are benchmarked against the experiments given in 3 cited references. The benchmark analysis shows that the ABAQUS results are in excellent agreement with the experiments

  17. Multiscale modeling of acoustic shielding materials

    NARCIS (Netherlands)

    Gao, K.; Dommelen, van J.A.W.; Geers, M.G.D.

    2012-01-01

    It is very important to protect high-tech systems from acoustic excitation when operating in a noisy environment. Some passive absorbing materials such as acoustic foams can improve the performance which depends on the interaction of the acoustic wave and the microstructure of the foam.

  18. Acoustical heat pumping engine

    Science.gov (United States)

    Wheatley, J.C.; Swift, G.W.; Migliori, A.

    1983-08-16

    The disclosure is directed to an acoustical heat pumping engine without moving seals. A tubular housing holds a compressible fluid capable of supporting an acoustical standing wave. An acoustical driver is disposed at one end of the housing and the other end is capped. A second thermodynamic medium is disposed in the housing near to but spaced from the capped end. Heat is pumped along the second thermodynamic medium toward the capped end as a consequence both of the pressure oscillation due to the driver and imperfect thermal contact between the fluid and the second thermodynamic medium. 2 figs.

  19. Renal dysplasia with the ipsilateral ectopic ureter mimicking abscess of the prostate

    Directory of Open Access Journals (Sweden)

    Grbić Dragan

    2014-01-01

    Full Text Available Introduction. In males the ectopic ureter usualy drains into the prostate (50%. During ureteric developement a thin membrane (Chawalla’s membrane separates the lumen of the ureter and the urogenital sinus at the point where the ureter joins the urogenital sinus. This membrane ruptures allowing urin to drain from the ureter to the urogenital sinus. The authors reported a case of renal dysplasia associated with ipsilateral uretral ectopia mimicking prostatic abscess. Case report. A subfebrile (37.3°C, 23-year-old patient, otherwise healthy, presented with persistent ascending perineal pain non-responsive to antibiotics and analgetics. Digitorectal examination (DRE showed asymmetric prostate with a soft, tender, buldging left lobe suggestive of prostatic abscess. The diagnosis was suspected using transrectal ultrasonography (TRUS, but the picture of the anechoic tubular structure in the left lobe of the prostate with a proximal undefined extraprostatic extension and a caudal intraprostatic blind end was incoclusive for the definitive diagnosis of prostatic abscess. Magnetic resonance imaging (MRI was ordered and definitive diagnosis of renal dysplasia associated with the ipsilateral ectopic ureter filled with inflamed content mimicking prostatic abscess was made. Transurethral incision/minimal resection of the distal, blindly closed end of left ectopic ureter was done. Endoscopic surgical treatment was sufficient for relief of clinical symptoms. The patient’s recovery was uneventful. Conclusion. To the best of our knowledge, a case of renal dysplasia with the ipsilateral ectopic ureter mimicking prostate abscess has not been reported so far. Cystic pelvic malformations in males may result from too craniall sprouting of the ureteral bud, with delayed absorption and ectopic opening of the distal end of the ureter.

  20. A Treatise on Acoustic Radiation. Volume 2. Acoustic Transducers

    Science.gov (United States)

    1983-01-01

    Newton) V (meter/sec) acoustical p (Newton/meter2 ) U (meter 3/sec) To display Eq. 1.53.1 in simple form we take time to be given by exp(- iot ) and choose...if all the C-component edges and e-drivers are in the tree, all the L-component "A edges and idrivers are in the cotree, all the algebraic equations...momentum and mass of the elastic field then become, (a) Al - V -T + F 278 W-4. ,-,- * * * 4 % • *.• Design of Acoustic Transducers IOT (b) I + VV-s

  1. Acoustic emission technique and its applications

    International Nuclear Information System (INIS)

    Sato, Ichiya; Sasaki, Soji

    1976-01-01

    Acoustic emission technique is described. The characteristics of acoustic emission signal, measurement techniques, and its application are explained. The acoustic signals are grouped into continuous and burst types. The continuous signal is due to plastic deformation, and the burst type is due to the generation and growth of cracks. The latter can be used for the identification of the position of cracks. The frequency of the acoustic emission is in the range from several tens of KHz to two MHz. Piezoelectric ceramics are used as the oscillators of sensors. The dynamic behavior of acoustic emission can be observed with a two-channel acoustic emission measuring apparatus. Multi-channel method was developed at Hitachi, Ltd., and is used for large structures. General computer identification method and simple zone identification method are explained. Noise elimination is important for the measurement, and the methods were studied. Examples of application are the observation of acoustic emission in the plastic deformation of steel, the tensile test of large welded material with natural defects, and others. The method will be used for the diagnosis and observation of large structures, the test and quality control of products. (Kato, T.)

  2. Abdominal Splenosis Mimicking Hepatic Tumor: A Case Report

    Directory of Open Access Journals (Sweden)

    Ming-Lun Yeh

    2008-11-01

    Full Text Available Diagnosis of abdominal splenosis is often undiagnosed until treatment for splenic rupture or splenectomy. This report describes a patient with splenosis mimicking hepatic tumor. The patient had a history of splenic trauma with splenectomy and chronic hepatitis C. After routine abdominal ultrasound revealed a liver nodule, further imaging studies, including magnetic resonance imaging, computed tomography and angiography, were performed. After the patient eventually underwent surgery, pathology revealed splenic tissue. Despite its distinguishable clinical features, splenosis is difficult to identify by modern imaging modalities. Therefore, accurate and timely diagnosis of this disease requires constant vigilance.

  3. A huge renal capsular leiomyoma mimicking retroperitoneal sarcoma

    Directory of Open Access Journals (Sweden)

    Lal Anupam

    2009-01-01

    Full Text Available A huge left renal capsular leiomyoma mimicking retroperitoneal sarcoma presented in a patient as an abdominal mass. Computed tomography displayed a large heterogeneous retro-peritoneal mass in the left side of the abdomen with inferior and medial displacement as well as loss of fat plane with the left kidney. Surgical exploration revealed a capsulated mass that was tightly adherent to the left kidney; therefore, total tumor resection with radical left nephrectomy was performed. Histopathology ultimately confirmed the benign nature of the mass. This is the largest leiomyoma reported in literature to the best of our knowledge.

  4. Simple bone cyst of mandible mimicking periapical cyst.

    Science.gov (United States)

    Hs, Charan Babu; Rai, Bhagawan Das; Nair, Manju A; Astekar, Madhusudan S

    2012-05-29

    Simple bone cysts (SBC) are pseudocysts occurring less commonly in the maxillofacial region. The uncertain and unclear etiopathogenesis led to numerous synonyms to refer this particular cyst. These cysts are devoid of an epithelial lining and are usually empty or contain blood or straw-colored fluid. In jaws initially it mimics a periapical cyst and later can lead to cortical bone expansion warranting for radical approach, which is seldom required. SBC is predominantly diagnosed in first two decades of life. Here we report a case of solitary bone cyst mimicking a periapical cyst of a mandibular molar in a 37-year-old patient.

  5. Predicting and auralizing acoustics in classrooms

    DEFF Research Database (Denmark)

    Christensen, Claus Lynge

    2005-01-01

    Although classrooms have fairly simple geometries, this type of room is known to cause problems when trying to predict their acoustics using room acoustics computer modeling. Some typical features from a room acoustics point of view are: Parallel walls, low ceilings (the rooms are flat), uneven...

  6. The Acoustical Apparatus of Rudolph Koenig.

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    1992-01-01

    Discusses the history of Rudolph Koenig's contribution to the development of acoustical apparatus. Contributions include the clock fork to determine absolute acoustic frequencies, a forerunner of the oscilloscope called the manometric flame, and an acoustic interference apparatus used in the Fourier synthesis of musical sounds. (MDH)

  7. Aero-acoustic Computations of Wind Turbines

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Michelsen, Jess; Sørensen, Jens Nørkær

    2002-01-01

    A numerical algorithm for acoustic noise generation is extended to 3D flows. The approach involves two parts comprising a viscous incompressible flow part and an inviscid acoustic part. In order to simulate noise generated from a wind turbine, the incompressible and acoustic equations are written...

  8. Acoustic perturbation equations and Lighthill's acoustic analogy for the human phonation

    Czech Academy of Sciences Publication Activity Database

    Zoerner, S.; Šidlof, Petr; Huppe, A.; Kaltenbacher, M.

    2013-01-01

    Roč. 19, 060309 (2013), s. 1-8 ISSN 1939-800X. [ICA 2013 - Meetings on Acoustics. Montreal, 02.06.2013-07.06.2013] R&D Projects: GA ČR(CZ) GAP101/11/0207 Institutional support: RVO:61388998 Keywords : vocal folds * CFD * computational aeroacoustics Subject RIV: BI - Acoustics http://asadl.org/poma/ resource /1/pmarcw/v19/i1/p060309_s1? view =print

  9. Sustainable Acoustic Metasurfaces for Sound Control

    Directory of Open Access Journals (Sweden)

    Paola Gori

    2016-01-01

    Full Text Available Sound attenuation with conventional acoustic materials is subject to the mass law and requires massive and bulky structures at low frequencies. A possible alternative solution is provided by the use of metamaterials, which are artificial materials properly engineered to obtain properties and characteristics that it is not possible to find in natural materials. Theory and applications of metamaterials, already consolidated in electromagnetism, can be extended to acoustics; in particular, they can be applied to improve the properties of acoustical panels. The design of acoustic metasurfaces that could effectively control transmitted sound in unconventional ways appears a significant subject to be investigated, given its wide-ranging possible applications. In this contribution, we investigate the application of a metasurface-inspired technique to achieve the acoustical insulation of an environment. The designed surface has subwavelength thickness and structuring and could be realized with cheap, lightweight and sustainable materials. We present a few examples of such structures and analyze their acoustical behavior by means of full-wave simulations.

  10. Mimicked cartilage scaffolds of silk fibroin/hyaluronic acid with stem cells for osteoarthritis surgery: Morphological, mechanical, and physical clues

    International Nuclear Information System (INIS)

    Jaipaew, Jirayut; Wangkulangkul, Piyanun; Meesane, Jirut; Raungrut, Pritsana; Puttawibul, Puttisak

    2016-01-01

    Osteoarthritis is a critical disease that comes from degeneration of cartilage tissue. In severe cases surgery is generally required. Tissue engineering using scaffolds with stem cell transplantation is an attractive approach and a challenge for orthopedic surgery. For sample preparation, silk fibroin (SF)/hyaluronic acid (HA) scaffolds in different ratios of SF/HA (w/w) (i.e., 100:0, 90:10, 80:20, and 70:30) were formed by freeze-drying. The morphological, mechanical, and physical clues were considered in this research. The morphological structure of the scaffolds was observed by scanning electron microscope. The mechanical and physical properties of the scaffolds were analyzed by compressive and swelling ratio testing, respectively. For the cell experiments, scaffolds were seeded and cultured with human umbilical cord-derived mesenchymal stem cells (HUMSCs). The cultured scaffolds were tested for cell viability, histochemistry, immunohistochemistry, and gene expression. The SF with HA scaffolds showed regular porous structures. Those scaffolds had a soft and elastic characteristic with a high swelling ratio and water uptake. The SF/HA scaffolds showed a spheroid structure of the cells in the porous structure particularly in the SF80 and SF70 scaffolds. Cells could express Col2a, Agg, and Sox9 which are markers for chondrogenesis. It could be deduced that SF/HA scaffolds showed significant clues for suitability in cartilage tissue engineering and in surgery for osteoarthritis. - Highlights: • Silk fibroin/Hyaluronic acid was fabricated into mimicked scaffolds. • Mimicked scaffolds were incorporated with stem cells for chondrogenesis. • Mimicked scaffolds showed the clues for chondrogenic regulation. • Mimicked scaffolds had suitable performance for cartilage tissue engineering • Mimicked scaffolds showed promise for osteoarthritis surgery.

  11. Mimicked cartilage scaffolds of silk fibroin/hyaluronic acid with stem cells for osteoarthritis surgery: Morphological, mechanical, and physical clues

    Energy Technology Data Exchange (ETDEWEB)

    Jaipaew, Jirayut [Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, 15 Karnjanavanich Road, Hat Yai, Songkhla, Thailand 90110 (Thailand); Wangkulangkul, Piyanun [Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, 15 Karnjanavanich Road, Hat Yai, Songkhla, Thailand 90110 (Thailand); Department of Surgery, Faculty of Medicine, Prince of Songkla University, 15 Karnjanavanich Road, Hat Yai, Songkhla, Thailand 90110 (Thailand); Meesane, Jirut, E-mail: jirutmeesane999@yahoo.co.uk [Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, 15 Karnjanavanich Road, Hat Yai, Songkhla, Thailand 90110 (Thailand); Raungrut, Pritsana [Department of Biomedical Science, Faculty of Medicine, Prince of Songkla University, 15 Karnjanavanich Road, Hat Yai, Songkhla, Thailand 90110 (Thailand); Puttawibul, Puttisak [Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, 15 Karnjanavanich Road, Hat Yai, Songkhla, Thailand 90110 (Thailand); Department of Surgery, Faculty of Medicine, Prince of Songkla University, 15 Karnjanavanich Road, Hat Yai, Songkhla, Thailand 90110 (Thailand)

    2016-07-01

    Osteoarthritis is a critical disease that comes from degeneration of cartilage tissue. In severe cases surgery is generally required. Tissue engineering using scaffolds with stem cell transplantation is an attractive approach and a challenge for orthopedic surgery. For sample preparation, silk fibroin (SF)/hyaluronic acid (HA) scaffolds in different ratios of SF/HA (w/w) (i.e., 100:0, 90:10, 80:20, and 70:30) were formed by freeze-drying. The morphological, mechanical, and physical clues were considered in this research. The morphological structure of the scaffolds was observed by scanning electron microscope. The mechanical and physical properties of the scaffolds were analyzed by compressive and swelling ratio testing, respectively. For the cell experiments, scaffolds were seeded and cultured with human umbilical cord-derived mesenchymal stem cells (HUMSCs). The cultured scaffolds were tested for cell viability, histochemistry, immunohistochemistry, and gene expression. The SF with HA scaffolds showed regular porous structures. Those scaffolds had a soft and elastic characteristic with a high swelling ratio and water uptake. The SF/HA scaffolds showed a spheroid structure of the cells in the porous structure particularly in the SF80 and SF70 scaffolds. Cells could express Col2a, Agg, and Sox9 which are markers for chondrogenesis. It could be deduced that SF/HA scaffolds showed significant clues for suitability in cartilage tissue engineering and in surgery for osteoarthritis. - Highlights: • Silk fibroin/Hyaluronic acid was fabricated into mimicked scaffolds. • Mimicked scaffolds were incorporated with stem cells for chondrogenesis. • Mimicked scaffolds showed the clues for chondrogenic regulation. • Mimicked scaffolds had suitable performance for cartilage tissue engineering • Mimicked scaffolds showed promise for osteoarthritis surgery.

  12. A low frequency acoustic insulator by using the acoustic metasurface to a Helmholtz resonator

    Directory of Open Access Journals (Sweden)

    Xiang Zhao

    2017-06-01

    Full Text Available Acoustic metasurfaces (AMSs are able to manipulate wavefronts at an anomalous angle through a subwavelength layer. Their application provide a new way to control sound waves in addition to traditional materials. In this work, we introduced the AMS into the design of a Helmholtz resonator (HR and studied the acoustic transmission through the modified HR in a pipe with one branch. The variation of sound insulation capacity with the phase gradient of the AMS was studied, and the results show that the AMS can remarkably lower the frequency band of the sound insulation without increasing the size. Our investigation provides a new degree of freedom for acoustic control with a Helmholtz resonator, which is of great significance in acoustic metasurface theory and sound insulation design.

  13. Principles of musical acoustics

    CERN Document Server

    Hartmann, William M

    2013-01-01

    Principles of Musical Acoustics focuses on the basic principles in the science and technology of music. Musical examples and specific musical instruments demonstrate the principles. The book begins with a study of vibrations and waves, in that order. These topics constitute the basic physical properties of sound, one of two pillars supporting the science of musical acoustics. The second pillar is the human element, the physiological and psychological aspects of acoustical science. The perceptual topics include loudness, pitch, tone color, and localization of sound. With these two pillars in place, it is possible to go in a variety of directions. The book treats in turn, the topics of room acoustics, audio both analog and digital, broadcasting, and speech. It ends with chapters on the traditional musical instruments, organized by family. The mathematical level of this book assumes that the reader is familiar with elementary algebra. Trigonometric functions, logarithms and powers also appear in the book, but co...

  14. Vibro-acoustic modeling and analysis of a coupled acoustic system comprising a partially opened cavity coupled with a flexible plate

    Science.gov (United States)

    Shi, Shuangxia; Su, Zhu; Jin, Guoyong; Liu, Zhigang

    2018-01-01

    This paper is concerned with the modeling and solution method of a three-dimensional (3D) coupled acoustic system comprising a partially opened cavity coupled with a flexible plate and an exterior field of semi-infinite size, which is ubiquitously encountered in architectural acoustics and is a reasonable representation of many engineering occasions. A general solution method is presented to predict the dynamic behaviors of the three-dimensional (3D) acoustic coupled system, in which the displacement of the plate and the sound pressure in the cavity are respectively constructed in the form of the two-dimensional and three-dimensional modified Fourier series with several auxiliary functions introduced to ensure the uniform convergence of the solution over the entire solution domain. The effect of the opening is taken into account via the work done by the sound pressure acting at the coupling aperture that is contributed from the vibration of particles on the acoustic coupling interface and on the structural-acoustic coupling interface. Both the acoustic coupling between finite cavity and exterior field and the structural-acoustic coupling between flexible plate and interior acoustic field are considered in the vibro-acoustic modeling of the three-dimensional acoustic coupled acoustic system. The dynamic responses of the coupled structural-acoustic system are obtained using the Rayleigh-Ritz procedure based on the energy expressions for the coupled system. The accuracy and effectiveness of the proposed method are validated through numerical examples and comparison with results obtained by the boundary element analysis. Furthermore, the influence of the opening and the cavity volume on the acoustic behaviors of opened cavity system is studied.

  15. Low frequency acoustic properties of a honeycomb-silicone rubber acoustic metamaterial

    Science.gov (United States)

    Gao, Nansha; Hou, Hong

    2017-04-01

    In order to overcome the influence of mass law on traditional acoustic materials and obtain a lightweight thin-layer structure which can effectively isolate the low frequency noises, a honeycomb-silicone rubber acoustic metamaterial was proposed. Experimental results show that the sound transmission loss (STL) of acoustic metamaterial in this paper is greatly higher than that of monolayer silicone rubber metamaterial. Based on the band structure, modal shapes, as well as the sound transmission simulation, the sound insulation mechanism of the designed honeycomb-silicone rubber structure was analyzed from a new perspective, which had been validated experimentally. Side length of honeycomb structure and thickness of the unit structure would affect STL in damping control zone. Relevant conclusions and design method provide a new concept for engineering noise control.

  16. Extraordinary acoustic transmission through annuluses in air and its applications in acoustic beam splitter and concentrator

    International Nuclear Information System (INIS)

    Ge, Yong; Liu, Shu-sen; Yuan, Shou-qi; Xia, Jian-ping; Guan, Yi-jun; Sun, Hong-xiang; Zhang, Shu-yi

    2016-01-01

    We report an extraordinary acoustic transmission through two layer annuluses made of metal cylinders in air both numerically and experimentally. The effect arises from the enhancement and reconstruction of the incident source induced by different Mie-resonance modes of the annuluses. The proposed system takes advantages of the consistency in the waveform between the input and output waves, the high amplitude amplification of output waves, and the easy adjustment of structure. More interestingly, we investigate the applications of the extraordinary acoustic transmission in the acoustic beam splitter and acoustic concentrator. Our finding should have an impact on ultrasonic applications.

  17. On Architectural Acoustics Design using Computer Simulation

    DEFF Research Database (Denmark)

    Schmidt, Anne Marie Due; Kirkegaard, Poul Henning

    2004-01-01

    The acoustical quality of a given building, or space within the building, is highly dependent on the architectural design. Architectural acoustics design has in the past been based on simple design rules. However, with a growing complexity in the architectural acoustic and the emergence of potent...... room acoustic simulation programs it is now possible to subjectively analyze and evaluate acoustic properties prior to the actual construction of a facility. With the right tools applied, the acoustic design can become an integrated part of the architectural design process. The aim of the present paper...... this information is discussed. The conclusion of the paper is that the application of acoustical simulation programs is most beneficial in the last of three phases but that an application of the program to the two first phases would be preferable and possible with an improvement of the interface of the program....

  18. Acoustically assisted diffusion through membranes and biomaterials

    International Nuclear Information System (INIS)

    Floros, J.D.; Liang, H.

    1994-01-01

    Part of a special section on the symposium ''Ultrasonic Applications in the Food Industry.'' The use of high-intensity ultrasound in food processing is reviewed. Acoustic radiation, or sound, can be used to monitor various operations or products or to alter a process or product; however, the direct use of sound to improve food processes is not very popular. High-intensity acoustic radiation induces various changes as it passes through a medium, largely as a result of heating, cavitation, agitation and shear stresses, compression and rarefaction, and turbulence. The diffusion of sound through a medium is influenced by factors such as the temperature, acoustic intensity, acoustic frequency, direction of the acoustic wave, pulsation of the acoustic wave, and properties of the medium. Some potential applications of acoustic energy in food processes are increased drying efficiency, acceleration of diffusion through polymeric and biological membranes, and enhanced diffusion through porous materials

  19. Holograms for acoustics.

    Science.gov (United States)

    Melde, Kai; Mark, Andrew G; Qiu, Tian; Fischer, Peer

    2016-09-22

    Holographic techniques are fundamental to applications such as volumetric displays, high-density data storage and optical tweezers that require spatial control of intricate optical or acoustic fields within a three-dimensional volume. The basis of holography is spatial storage of the phase and/or amplitude profile of the desired wavefront in a manner that allows that wavefront to be reconstructed by interference when the hologram is illuminated with a suitable coherent source. Modern computer-generated holography skips the process of recording a hologram from a physical scene, and instead calculates the required phase profile before rendering it for reconstruction. In ultrasound applications, the phase profile is typically generated by discrete and independently driven ultrasound sources; however, these can only be used in small numbers, which limits the complexity or degrees of freedom that can be attained in the wavefront. Here we introduce monolithic acoustic holograms, which can reconstruct diffraction-limited acoustic pressure fields and thus arbitrary ultrasound beams. We use rapid fabrication to craft the holograms and achieve reconstruction degrees of freedom two orders of magnitude higher than commercial phased array sources. The technique is inexpensive, appropriate for both transmission and reflection elements, and scales well to higher information content, larger aperture size and higher power. The complex three-dimensional pressure and phase distributions produced by these acoustic holograms allow us to demonstrate new approaches to controlled ultrasonic manipulation of solids in water, and of liquids and solids in air. We expect that acoustic holograms will enable new capabilities in beam-steering and the contactless transfer of power, improve medical imaging, and drive new applications of ultrasound.

  20. Proposed frustrated-total-reflection acoustic sensing method

    International Nuclear Information System (INIS)

    Hull, J.R.

    1981-01-01

    Modulation of electromagnetic energy transmission through a frustrated-total-reflection device by pressure-induced changes in the index of refraction is proposed for use as an acoustic detector. Maximum sensitivity occurs for angles of incidence near the critical angle. The minimum detectable pressure in air is limited by Brownian noise. Acoustic propagation losses and diffraction of the optical beam by the acoustic signal limit the minimum acoustic wavelength to lengths of the order of the spatial extent of the optical beam. The response time of the method is fast enough to follow individual acoustic waves

  1. Epithelioid sarcoma mimicking abscess: review of the MRI appearances

    International Nuclear Information System (INIS)

    Dion, E.; Forest, M.; Brasseur, J.L.; Grenier, P.; Amoura, Z.

    2001-01-01

    A case of epithelioid sarcoma involving the soft tissue of the ankle is presented. The tumor was a hemorrhagic, fluid-filled, multiloculated lesion with inflammatory changes in the surrounding planes. Tuberculous abscess was diagnosed on the basis of the clinical picture, ultrasound and MRI findings. Surgical exploration of the ankle mass was carried out because of lack of local healing while the patient's general and pulmonary status improved on antituberculosis treatment. This was an unusual case of epithelioid sarcoma mimicking a multilocular abscess. (orig.)

  2. Hızma Induced Papul of Nose Mimicking Pyogenic Granuloma

    Directory of Open Access Journals (Sweden)

    Mualla Polat

    2014-09-01

    Full Text Available The application of body piercing is popular among young people, who consider it as a sign of marginality, beauty, or group identity. Piercing procedure is observed to cause a large number of complications such as infections, pain, inflammatory reactions, bleeding, dental fractures or fissures, and gingival damage, etc., mostly in young individuals. Hizma is a traditional body ornament worn by Anatolian women via a piercing procedure. Herein, we describe a papule of nose mimicking pyogenic granuloma as an uncommon complication of Hızma.

  3. Possible neuro-Sweet disease mimicking brain tumor in the medulla oblongata--case report.

    Science.gov (United States)

    Akiba, Chihiro; Esaki, Takanori; Ando, Maya; Furuya, Tsuyoshi; Noda, Kazuyuki; Nakao, Yasuaki; Yamamoto, Takuji; Okuma, Yasuyuki; Mori, Kentaro

    2011-01-01

    A 62-year-old male presented with a rare case of possible neuro-Sweet Disease (NSD) mimicking brain tumor in the medulla oblongata, manifesting as numbness in the bilateral upper and lower extremities, gait disturbance, dysarthria, and swallowing disturbance which gradually deteriorated over 3 months. Magnetic resonance imaging showed a mass lesion in the medulla oblongata, extending to the upper cervical cord with rim enhancement by gadolinium. The preoperative diagnosis was brain tumor, such as glioma, or inflammatory disease. His neurological symptoms gradually deteriorated, so biopsy was performed through the midline suboccipital approach. Histological examination showed infiltration of inflammatory cells, mainly lymphocytes and macrophages. Human leukocyte antigen typing showed Cw1 and B54 which strongly suggested possible NSD. Steroid pulse therapy was started after surgery and the clinical symptoms improved. Neurosurgeons should be aware of inflammatory disorders such as NSD mimicking brain tumor.

  4. Acoustic cavitation studies

    Science.gov (United States)

    Crum, L. A.

    1981-09-01

    The primary thrust of this study was toward a more complete understanding of general aspects of acoustic cavitation. The effect of long-chain polymer additives on the cavitation threshold was investigated to determine if they reduced the acoustic cavitation threshold in a similar manner to the observed reduction in the cavitation index in hydrodynamic cavitation. Measurements were made of the acoustic cavitation threshold as a function of polymer concentration for additives such as guar gum and polyethelene oxide. The measurements were also made as a function of dissolved gas concentration, surface tension and viscosity. It was determined that there was a significant increase in the acoustic cavitation threshold for increased concentrations of the polymer additives (measurable effects could be obtained for concentrations as low as a few parts per million). One would normally expect that an additive that reduces surface tension to decrease the pressure required to cause a cavity to grow and thus these additives, at first thought, should reduce the threshold. However, even in the hydrodynamic case, the threshold was increased. In both of the hydrodynamic cases considered, the explanation for the increased threshold was given in terms of changed fluid dynamics rather than changed physical properties of the fluid.

  5. Advanced Active Acoustics Lab (AAAL)

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Active Acoustics Lab (AAAL) is a state-of-the-art Undersea Warfare (USW) acoustic data analysis facility capable of both active and passive underwater...

  6. Degenerated uterine leiomyomas mimicking malignant bilateral ovarian surface epithelial tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yi Boem Ha; Lee, Hae Kyung; Lee, Min Hee; Choi, Seo Youn; Chung, Soo Ho [Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of)

    2017-07-15

    Uterine leiomyomas are the most common benign uterine neoplasms. Undegenerated uterine leiomyomas are easily recognizable by the typical imaging findings on radiologic studies. However, degenerated fibroids can have unusual and variable appearances. The atypical appearances due to degenerative changes may cause confusion in diagnosis of leiomyomas. In this article, we report a case of a patient with extensive cystic and myxoid degeneration of uterine leiomyoma, mimicking malignant bilateral ovarian surface epithelial tumors.

  7. An Experimental Introduction to Acoustics

    Science.gov (United States)

    Black, Andy Nicholas; Magruder, Robert H.

    2017-11-01

    Learning and understanding physics requires more than studying physics texts. It requires doing physics. Doing research is a key opportunity for students to connect physical principles with their everyday experience. A powerful way to introduce students to research and technique is through subjects in which they might find interest. Presented is an experiment that serves to introduce an advanced undergraduate or high school student to conducting research in acoustics via an experiment involving a standard dreadnought acoustic guitar, recording industry-related equipment, and relevant industrial analysis software. This experimental process is applicable to a wide range of acoustical topics including both acoustic and electric instruments. Also, the student has a hands-on experience with relevant audio engineering technology to study physical principles.

  8. Acoustic holograms of active regions

    International Nuclear Information System (INIS)

    Chou, Dean-Yi

    2008-01-01

    We propose a method to study solar magnetic regions in the solar interior with the principle of optical holography. A magnetic region in the solar interior scatters the solar background acoustic waves. The scattered waves and background waves could form an interference pattern on the solar surface. We investigate the feasibility of detecting this interference pattern on the solar surface, and using it to construct the three-dimensional scattered wave from the magnetic region with the principle of optical holography. In solar acoustic holography, the background acoustic waves play the role of reference wave; the magnetic region plays the role of the target object; the interference pattern, acoustic power map, on the solar surface plays the role of the hologram.

  9. Acoustic holograms of active regions

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Dean-Yi [Physics Department, National Tsing Hua University, Hsinchu, 30013, Taiwan (China)], E-mail: chou@phys.nthu.edu.tw

    2008-10-15

    We propose a method to study solar magnetic regions in the solar interior with the principle of optical holography. A magnetic region in the solar interior scatters the solar background acoustic waves. The scattered waves and background waves could form an interference pattern on the solar surface. We investigate the feasibility of detecting this interference pattern on the solar surface, and using it to construct the three-dimensional scattered wave from the magnetic region with the principle of optical holography. In solar acoustic holography, the background acoustic waves play the role of reference wave; the magnetic region plays the role of the target object; the interference pattern, acoustic power map, on the solar surface plays the role of the hologram.

  10. Radiological evaluation of acoustic neurinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Tae; Park, Chang Yun; Choi, Byung So [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1974-04-15

    All 25 patients surgically proven acoustic neurinoma was analysed clinically, radiographically at Severance Hospital of Yonsei Univ. The patients not proved surgically in spite of clinical diagnosis of acoustic neurinoma was excluded from this study. The results are summarized as follows; The clinical findings are; 1. The incidence of tumor in female was twice more frequent than in male and the range of age was 20-50 years peak of age at onset of symptom. 2. The clinical symptoms were variable from unilateral hearing impairment or less (100%), headache (84%) to tinnitus (60%) in order of frequency. 3. The tumor growth in the left cerebellopontine angle was twice more than in the right side with the radio of 16:8. However, in one case bilateral simultaneous growth of acoustic neurinoma was noted. The radiological findings are: The best radiographic method to study the shape and size of internal acoustic canal to demonstrate erosion or destruction of petrous pyramida was considered to be straight frontal view and tomography of the skull in our series. 1. The shape of internal acoustic canal in tumors were straight (in 2 cases), bulbous (in 12 cases), and flared (in 11 cases). Particularly there was erosion or destruction of petrous bone in all of the flared cases of canal. 2. The acoustic meatal erosion was mainly suprameatal in 14 cases of 17 which was noted definite erosion radiographically. 3. The difference of height (vertical diameter) of both side of acoustic canal were follows; 6 cases among 25 was in the range of 0-2 mm measurement, remainder was more than 2 mm. Hence the variation in greater than 1 mm in between both sides of canal in same patient should be regard as abnormal as of acoustic neurinoma. 4. The carotid angiogram shows hydrocephalic pattern in 12 cases among 17. 5. In the vertebral angiogram of 8 cases, anterolateral displacement of basilar artery (in 6 caes), the upward displacement of superior cerebellar artery (in 4 cases) was common findings

  11. Radiological evaluation of acoustic neurinoma

    International Nuclear Information System (INIS)

    Lee, Jong Tae; Park, Chang Yun; Choi, Byung So

    1974-01-01

    All 25 patients surgically proven acoustic neurinoma was analysed clinically, radiographically at Severance Hospital of Yonsei Univ. The patients not proved surgically in spite of clinical diagnosis of acoustic neurinoma was excluded from this study. The results are summarized as follows; The clinical findings are; 1. The incidence of tumor in female was twice more frequent than in male and the range of age was 20-50 years peak of age at onset of symptom. 2. The clinical symptoms were variable from unilateral hearing impairment or less (100%), headache (84%) to tinnitus (60%) in order of frequency. 3. The tumor growth in the left cerebellopontine angle was twice more than in the right side with the radio of 16:8. However, in one case bilateral simultaneous growth of acoustic neurinoma was noted. The radiological findings are: The best radiographic method to study the shape and size of internal acoustic canal to demonstrate erosion or destruction of petrous pyramida was considered to be straight frontal view and tomography of the skull in our series. 1. The shape of internal acoustic canal in tumors were straight (in 2 cases), bulbous (in 12 cases), and flared (in 11 cases). Particularly there was erosion or destruction of petrous bone in all of the flared cases of canal. 2. The acoustic meatal erosion was mainly suprameatal in 14 cases of 17 which was noted definite erosion radiographically. 3. The difference of height (vertical diameter) of both side of acoustic canal were follows; 6 cases among 25 was in the range of 0-2 mm measurement, remainder was more than 2 mm. Hence the variation in greater than 1 mm in between both sides of canal in same patient should be regard as abnormal as of acoustic neurinoma. 4. The carotid angiogram shows hydrocephalic pattern in 12 cases among 17. 5. In the vertebral angiogram of 8 cases, anterolateral displacement of basilar artery (in 6 caes), the upward displacement of superior cerebellar artery (in 4 cases) was common findings

  12. Acoustic Purcell Effect for Enhanced Emission

    KAUST Repository

    Landi, Maryam

    2018-03-13

    We observe that our experimentally measured emission power enhancement of a speaker inside a previously proposed metacavity agrees with our numerically calculated enhancement of the density of states (DOS) of the source-cavity system. We interpret the agreement by formulating a relation between the emitted sound power and the acoustic DOS. The formulation is an analog to Fermi’s golden rule in quantum emission. The formulation complements the radiation impedance theory in traditional acoustics for describing sound emission. Our study bridges the gap between acoustic DOS and the acoustic Purcell effect for sound emission enhancement.

  13. Acoustic Purcell Effect for Enhanced Emission

    KAUST Repository

    Landi, Maryam; Zhao, Jiajun; Prather, Wayne E.; Wu, Ying; Zhang, Likun

    2018-01-01

    We observe that our experimentally measured emission power enhancement of a speaker inside a previously proposed metacavity agrees with our numerically calculated enhancement of the density of states (DOS) of the source-cavity system. We interpret the agreement by formulating a relation between the emitted sound power and the acoustic DOS. The formulation is an analog to Fermi’s golden rule in quantum emission. The formulation complements the radiation impedance theory in traditional acoustics for describing sound emission. Our study bridges the gap between acoustic DOS and the acoustic Purcell effect for sound emission enhancement.

  14. Evaluating the Acoustic Benefits of Over-the-Rotor Acoustic Treatments Installed on the Advanced Noise Control Fan

    Science.gov (United States)

    Gazella, Matthew R.; Takakura, Tamuto; Sutliff, Daniel L.; Bozak, Richard F.; Tester, Brian J.

    2017-01-01

    Over the last 15 years, over-the-rotor acoustic treatments have been evaluated by NASA with varying success. Recently, NASA has been developing the next generation of over-the-rotor acoustic treatments for fan noise reduction. The NASA Glenn Research Centers Advanced Noise Control Fan was used as a Low Technology Readiness Level test bed. A rapid prototyped in-duct array consisting of 50 microphones was employed, and used to correlate the in-duct analysis to the far-field acoustic levels and to validate an existing beam-former method. The goal of this testing was to improve the Technology Readiness Level of various over-the-rotor acoustic treatments by advancing the understanding of the physical mechanisms and projecting the far-field acoustic benefit.

  15. Nonlinear acoustics of water-saturated marine sediments

    DEFF Research Database (Denmark)

    Jensen, Leif Bjørnø

    1976-01-01

    Interest in the acoustic qualities of water-saturated marine sediments has increased considerably during recent years. The use of sources of high-intensity sound in oil propsecting, in geophysical and geological studies of bottom and subbottom materials and profiles and recently in marine...... archaeology has emphasized the need of information about the nonlinear acoustic qualities of water-saturated marine sediments. While the acoustic experiments and theoretical investigations hitherto performed have concentrated on a determination of the linear acoustic qualities of water-saturated marine...... sediments, their parameters of nonlinear acoustics are still unexplored. The strong absorption, increasing about linearly with frequency, found in most marine sediments and the occurrence of velocity dispersion by some marine sediments restrict the number of nonlinear acoustic test methods traditionally...

  16. Acoustic-noise-optimized diffusion-weighted imaging.

    Science.gov (United States)

    Ott, Martin; Blaimer, Martin; Grodzki, David M; Breuer, Felix A; Roesch, Julie; Dörfler, Arnd; Heismann, Björn; Jakob, Peter M

    2015-12-01

    This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.

  17. Hypofractionated stereotactic irradiation. Basic and clinical researches

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Miyakawa, Akifumi; Iwata, Hiromitsu; Otsuka, Shinya; Ogino, Hiroyuki; Ayakawa, Shiho

    2011-01-01

    Hypofractionated stereotactic radiotherapy (SRT) has a number of biological advantages over single-session radiosurgery. An apparent trend is seen in the clinic towards shift from the latter to the former; however, there is no adequate model to convert single doses to hypofractionated doses. The linear-quadratic model overestimates the effect of single-fraction radiation. This should be kept in mind in evaluating the doses of stereotactic irradiation. ''Biological effective dose'' should not be used in radiosurgery and hypofractionated SRT. Clinically, we have used 3- to 10-fraction SRT for acoustic neuroma and benign skull base tumors using cyberknife and tomotherapy. Preliminary results are encouraging. (author)

  18. Pattern recognition methods for acoustic emission analysis

    International Nuclear Information System (INIS)

    Doctor, P.G.; Harrington, T.P.; Hutton, P.H.

    1979-07-01

    Models have been developed that relate the rate of acoustic emissions to structural integrity. The implementation of these techniques in the field has been hindered by the noisy environment in which the data must be taken. Acoustic emissions from noncritical sources are recorded in addition to those produced by critical sources, such as flaws. A technique is discussed for prescreening acoustic events and filtering out those that are produced by noncritical sources. The methodology that was investigated is pattern recognition. Three different pattern recognition techniques were applied to a data set that consisted of acoustic emissions caused by crack growth and acoustic signals caused by extraneous noise sources. Examination of the acoustic emission data presented has uncovered several features of the data that can provide a reasonable filter. Two of the most valuable features are the frequency of maximum response and the autocorrelation coefficient at Lag 13. When these two features and several others were combined with a least squares decision algorithm, 90% of the acoustic emissions in the data set were correctly classified. It appears possible to design filters that eliminate extraneous noise sources from flaw-growth acoustic emissions using pattern recognition techniques

  19. Perspective: Acoustic metamaterials in transition

    KAUST Repository

    Wu, Ying; Yang, Min; Sheng, Ping

    2017-01-01

    Acoustic metamaterials derive their novel characteristics from the interaction between acoustic waves with designed structures. Since its inception seventeen years ago, the field has been driven by fundamental geometric and physical principles

  20. A Rare Case Report of Bilateral Complex Macrocystic Adrenal Hemorrhage Mimicking Fetal Neuroblastoma

    OpenAIRE

    Sindhwani, Geetika; Patel, Viral; Jain, Abhinav

    2018-01-01

    Fetal and neonatal adrenal glands are large vascular organs, which make them vulnerable to frequent bleeding. Although neonatal adrenal hemorrhage is commonly reported, it is rarely diagnosed on antenatal sonography. We present a rare case of prenatally diagnosed bilateral adrenal hemorrhage, which mimicked antenatal neuroblastoma.

  1. Idelalisib-induced colitis and skin eruption mimicking graft-versus-host disease.

    Science.gov (United States)

    Hammami, Muhammad Bader; Al-Taee, Ahmad; Meeks, Marshall; Fesler, Mark; Hurley, M Yadira; Cao, Dengfeng; Lai, Jin-Ping

    2017-04-01

    Idelalisib is a selective inhibitor of the delta isoform of phosphatidylinositol 3-kinase which was approved by the United States Federal Drug Administration in 2014 for the treatment of relapsed chronic lymphocytic leukemia and indolent non-Hodgkin lymphoma. Drug-induced injury of the gastrointestinal tract is a relatively frequent but usually under-recognized disease entity. We report the case of a 56-year-old male with a history of relapsed follicular lymphoma status post allogenic bone marrow transplant who developed severe diarrhea with a skin eruption mimicking graft-versus-host disease (GVHD) 6 months after starting idelalisib. He underwent a colonoscopy demonstrating a grossly normal-appearing colon and terminal ileum. Biopsies taken during the procedure revealed mild active ileitis, colitis, and proctitis with frequent epithelial apoptosis, and focal intra-epithelial lymphocytosis. Skin biopsies revealed sub-acute spongiotic dermatitis suggestive of either contact dermatitis or an eczematous drug reaction. Symptoms were attributed to idelalisib given their resolution with withdrawal of the drug in conjunction with the skin and colonic biopsies. High clinical suspicion and awareness of the histological features of idelalisib-associated colitis is important to distinguish it from potential mimickers such as GVHD and infectious colitis.

  2. Amplified biosensing using the horseradish peroxidase-mimicking DNAzyme as an electrocatalyst.

    Science.gov (United States)

    Pelossof, Gilad; Tel-Vered, Ran; Elbaz, Johann; Willner, Itamar

    2010-06-01

    The hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme is assembled on Au electrodes. It reveals bioelectrocatalytic properties and electrocatalyzes the reduction of H(2)O(2). The bioelectrocatalytic functions of the hemin/G-quadruplex DNAzyme are used to develop electrochemical sensors that follow the activity of glucose oxidase and biosensors for the detection of DNA or low-molecular-weight substrates (adenosine monophosphate, AMP). Hairpin nucleic structures that include the G-quadruplex sequence in a caged configuration and the nucleic acid sequence complementary to the analyte DNA, or the aptamer sequence for AMP, are immobilized on Au-electrode surfaces. In the presence of the DNA analyte, or AMP, the hairpin structures are opened, and the hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme structures are generated on the electrode surfaces. The bioelectrocatalytic cathodic currents generated by the functionalized electrodes, upon the electrochemical reduction of H(2)O(2), provide a quantitative measure for the detection of the target analytes. The DNA target was analyzed with a detection limit of 1 x 10(-12) M, while the detection limit for analyzing AMP was 1 x 10(-6) M. Methods to regenerate the sensing surfaces are presented.

  3. Overview of IgG4-Related Tubulointerstitial Nephritis and Its Mimickers

    Directory of Open Access Journals (Sweden)

    Hyeon Joo Jeong

    2016-01-01

    Full Text Available Tubulointerstitial nephritis (TIN is the most common form of renal involvement in IgG4-related disease. It is characterized by a dominant infiltrate of IgG4-positive plasma cells in the interstitium and storiform fibrosis. Demonstration of IgG4-positive plasma cells is essential for diagnosis, but the number of IgG4-positive cells and the ratio of IgG4-positive/IgG-positive plasma cells may vary from case to case and depending on the methods of tissue sampling even in the same case. IgG4-positive plasma cells can be seen in TIN associated with systemic lupus erythematosus, Sjögren syndrome, or anti-neutrophil cytoplasmic antibody–associated vasculitis, which further add diagnostic confusion and difficulties. To have a more clear view of IgG4-TIN and to delineate differential points from other TIN with IgG4-positive plasma cell infiltrates, clinical and histological features of IgG4-TIN and its mimickers were reviewed. In the rear part, cases suggesting overlap of IgG4-TIN and its mimickers and glomerulonephritis associated with IgG4-TIN were briefly described.

  4. CT findings of foreign body reaction to retained endoloop ligature plastic tube mimicking acute appendicitis: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Jae Hong; Kang, Chae Hoon; Choi, Soo Jung; Park, Man Soo; Jung, Seung Mun; Ryu, Dae Shick; Shin, Dong Rock [Dept. of Radiology, GangNeung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of)

    2016-07-15

    Many hospitals experience one or more retained surgical instrument events with risk of patient morbidity and medicolegal problems. Identification of retained surgical instrument is important. The radiologists should be familiar with imaging finding of retained surgical instrument. In a 62-year-old female with a retained plastic tube, localized peritoneal infiltration around air-containing tubular structure mimicked acute appendicitis on abdomen computed tomography (CT), one year after laparoscopic cholecystectomy. We reported CT findings of foreign body reaction related to retained Endoloop ligature plastic tube mimicking acute appendicitis.

  5. CT findings of foreign body reaction to retained endoloop ligature plastic tube mimicking acute appendicitis: A case report

    International Nuclear Information System (INIS)

    Ahn, Jae Hong; Kang, Chae Hoon; Choi, Soo Jung; Park, Man Soo; Jung, Seung Mun; Ryu, Dae Shick; Shin, Dong Rock

    2016-01-01

    Many hospitals experience one or more retained surgical instrument events with risk of patient morbidity and medicolegal problems. Identification of retained surgical instrument is important. The radiologists should be familiar with imaging finding of retained surgical instrument. In a 62-year-old female with a retained plastic tube, localized peritoneal infiltration around air-containing tubular structure mimicked acute appendicitis on abdomen computed tomography (CT), one year after laparoscopic cholecystectomy. We reported CT findings of foreign body reaction related to retained Endoloop ligature plastic tube mimicking acute appendicitis

  6. Hot topics: Signal processing in acoustics

    Science.gov (United States)

    Gaumond, Charles F.

    2005-09-01

    Signal processing in acoustics is a multidisciplinary group of people that work in many areas of acoustics. We have chosen two areas that have shown exciting new applications of signal processing to acoustics or have shown exciting and important results from the use of signal processing. In this session, two hot topics are shown: the use of noiselike acoustic fields to determine sound propagation structure and the use of localization to determine animal behaviors. The first topic shows the application of correlation on geo-acoustic fields to determine the Greens function for propagation through the Earth. These results can then be further used to solve geo-acoustic inverse problems. The first topic also shows the application of correlation using oceanic noise fields to determine the Greens function through the ocean. These results also have utility for oceanic inverse problems. The second topic shows exciting results from the detection, localization, and tracking of marine mammals by two different groups. Results from detection and localization of bullfrogs are shown, too. Each of these studies contributed to the knowledge of animal behavior. [Work supported by ONR.

  7. Physics of thermo-acoustic sound generation

    Science.gov (United States)

    Daschewski, M.; Boehm, R.; Prager, J.; Kreutzbruck, M.; Harrer, A.

    2013-09-01

    We present a generalized analytical model of thermo-acoustic sound generation based on the analysis of thermally induced energy density fluctuations and their propagation into the adjacent matter. The model provides exact analytical prediction of the sound pressure generated in fluids and solids; consequently, it can be applied to arbitrary thermal power sources such as thermophones, plasma firings, laser beams, and chemical reactions. Unlike existing approaches, our description also includes acoustic near-field effects and sound-field attenuation. Analytical results are compared with measurements of sound pressures generated by thermo-acoustic transducers in air for frequencies up to 1 MHz. The tested transducers consist of titanium and indium tin oxide coatings on quartz glass and polycarbonate substrates. The model reveals that thermo-acoustic efficiency increases linearly with the supplied thermal power and quadratically with thermal excitation frequency. Comparison of the efficiency of our thermo-acoustic transducers with those of piezoelectric-based airborne ultrasound transducers using impulse excitation showed comparable sound pressure values. The present results show that thermo-acoustic transducers can be applied as broadband, non-resonant, high-performance ultrasound sources.

  8. PORTABLE ACOUSTIC MONITORING PACKAGE (PAMP)

    Energy Technology Data Exchange (ETDEWEB)

    John l. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Deepak Mehra

    2003-07-01

    The 1st generation acoustic monitoring package was designed to detect and analyze weak acoustic signals inside natural gas transmission lines. Besides a microphone it housed a three-inch diameter aerodynamic acoustic signal amplifier to maximize sensitivity to leak induced {Delta}p type signals. The theory and test results of this aerodynamic signal amplifier was described in the master's degree thesis of our Research Assistant Deepak Mehra who is about to graduate. To house such a large three-inch diameter sensor required the use of a steel 300-psi rated 4 inch weld neck flange, which itself weighed already 29 pounds. The completed 1st generation Acoustic Monitoring Package weighed almost 100 pounds. This was too cumbersome to mount in the field, on an access port at a pipeline shut-off valve. Therefore a 2nd generation and truly Portable Acoustic Monitor was built. It incorporated a fully self-contained {Delta}p type signal sensor, rated for line pressures up to 1000 psi with a base weight of only 6 pounds. This is the Rosemont Inc. Model 3051CD-Range 0, software driven sensor, which is believed to have industries best total performance. Its most sensitive unit was purchased with a {Delta}p range from 0 to 3 inch water. This resulted in the herein described 2nd generation: Portable Acoustic Monitoring Package (PAMP) for pipelines up to 1000 psi. Its 32-pound total weight includes an 18-volt battery. Together with a 3 pound laptop with its 4-channel data acquisition card, completes the equipment needed for field acoustic monitoring of natural gas transmission pipelines.

  9. ISAT: The mega-fauna acoustic tracking system

    KAUST Repository

    De la Torre, Pedro

    2013-06-01

    The acoustic tracking module of the Integrated Satellite and Acoustic Telemetry (iSAT) system is discussed in detail. iSAT is capable of detecting the relative direction of an acoustic source by measuring the order of arrival (OOA) of the acoustic signal to each hydrophone in a triangular array. The characteristics of the hydrophones, the projector, and the target acoustic signal used for iSAT are described. Initially it is designed to study the movements of whale sharks (Rhincodon typus), but it could potentially be used to describe high resolution movements of other marine species. © 2013 IEEE.

  10. Design of the Acoustic Signal Receiving Unit of Acoustic Telemetry While Drilling

    Directory of Open Access Journals (Sweden)

    Li Zhigang

    2016-01-01

    Full Text Available Signal receiving unit is one of the core units of the acoustic telemetry system. A new type of acoustic signal receiving unit is designed to solve problems of the existing devices. The unit is a short joint in whole. It not only can receive all the acoustic signals transmitted along the drill string, without losing any signal, but will not bring additional vibration and interference. In addition, the structure of the amplitude transformer is designed, which can amplify the signal amplitude and improve the receiving efficiency. The design of the wireless communication module makes the whole device can be used in normal drilling process when the drill string is rotating. So, it does not interfere with the normal drilling operation.

  11. Acoustic levitation of a large solid sphere

    International Nuclear Information System (INIS)

    Andrade, Marco A. B.; Bernassau, Anne L.; Adamowski, Julio C.

    2016-01-01

    We demonstrate that acoustic levitation can levitate spherical objects much larger than the acoustic wavelength in air. The acoustic levitation of an expanded polystyrene sphere of 50 mm in diameter, corresponding to 3.6 times the wavelength, is achieved by using three 25 kHz ultrasonic transducers arranged in a tripod fashion. In this configuration, a standing wave is created between the transducers and the sphere. The axial acoustic radiation force generated by each transducer on the sphere was modeled numerically as a function of the distance between the sphere and the transducer. The theoretical acoustic radiation force was verified experimentally in a setup consisting of an electronic scale and an ultrasonic transducer mounted on a motorized linear stage. The comparison between the numerical and experimental acoustic radiation forces presents a good agreement.

  12. Acoustic levitation of a large solid sphere

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marco A. B., E-mail: marcobrizzotti@gmail.com [Institute of Physics, University of São Paulo, São Paulo 05508-090 (Brazil); Bernassau, Anne L. [School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Adamowski, Julio C. [Department of Mechatronics and Mechanical Systems Engineering, Escola Politécnica, University of São Paulo, São Paulo 05508-030 (Brazil)

    2016-07-25

    We demonstrate that acoustic levitation can levitate spherical objects much larger than the acoustic wavelength in air. The acoustic levitation of an expanded polystyrene sphere of 50 mm in diameter, corresponding to 3.6 times the wavelength, is achieved by using three 25 kHz ultrasonic transducers arranged in a tripod fashion. In this configuration, a standing wave is created between the transducers and the sphere. The axial acoustic radiation force generated by each transducer on the sphere was modeled numerically as a function of the distance between the sphere and the transducer. The theoretical acoustic radiation force was verified experimentally in a setup consisting of an electronic scale and an ultrasonic transducer mounted on a motorized linear stage. The comparison between the numerical and experimental acoustic radiation forces presents a good agreement.

  13. Acoustic levitation of a large solid sphere

    Science.gov (United States)

    Andrade, Marco A. B.; Bernassau, Anne L.; Adamowski, Julio C.

    2016-07-01

    We demonstrate that acoustic levitation can levitate spherical objects much larger than the acoustic wavelength in air. The acoustic levitation of an expanded polystyrene sphere of 50 mm in diameter, corresponding to 3.6 times the wavelength, is achieved by using three 25 kHz ultrasonic transducers arranged in a tripod fashion. In this configuration, a standing wave is created between the transducers and the sphere. The axial acoustic radiation force generated by each transducer on the sphere was modeled numerically as a function of the distance between the sphere and the transducer. The theoretical acoustic radiation force was verified experimentally in a setup consisting of an electronic scale and an ultrasonic transducer mounted on a motorized linear stage. The comparison between the numerical and experimental acoustic radiation forces presents a good agreement.

  14. Transmission characteristics of acoustic amplifier in thermoacoustic engine

    International Nuclear Information System (INIS)

    Sun Daming; Qiu Limin; Wang Bo; Xiao Yong

    2008-01-01

    Thermoacoustic engines are promising in practical applications for the merits of simple configuration, reliable operation and environmentally friendly working gas. An acoustic amplifier can increase the output pressure amplitude of a thermoacoustic engine (TE) and improve the matching between the engine and its load. In order to make full use of an acoustic amplifier, the transmission characteristics are studied based on linear thermoacoustic theory. Computational and experimental results show that the amplifying ability of an acoustic amplifier is mainly determined by its geometry parameters and output resistance impedance. The amplifying ability of an acoustic amplifier with appropriate length and diameter reaches its maximum when the output resistance impedance is infinite. It is also shown that the acoustic amplifier consumes an amount of acoustic power when amplifying pressure amplitude and the acoustic power consumption increases with amplifying ratio. Furthermore, a novel cascade acoustic amplifier is proposed, which has a much stronger amplifying ability with reduced acoustic power consumption. In experiments, a two-stage cascade acoustic amplifier amplifies the pressure ratio from 1.177 to 1.62 and produces a pressure amplitude of 0.547 MPa with nitrogen of 2.20 MPa as working gas. Good agreements are obtained between the theoretical analysis and experimental results. This research is instructive for comprehensively understanding the mechanism and making full use of the acoustic amplifier

  15. Nanoliter-droplet acoustic streaming via ultra high frequency surface acoustic waves.

    Science.gov (United States)

    Shilton, Richie J; Travagliati, Marco; Beltram, Fabio; Cecchini, Marco

    2014-08-06

    The relevant length scales in sub-nanometer amplitude surface acoustic wave-driven acoustic streaming are demonstrated. We demonstrate the absence of any physical limitations preventing the downscaling of SAW-driven internal streaming to nanoliter microreactors and beyond by extending SAW microfluidics up to operating frequencies in the GHz range. This method is applied to nanoliter scale fluid mixing. © 2014 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Sea Turtle Acoustic Telemetry Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Acoustic transmitters attached to sea turtles captured in various fishing gear enable the animals to be passively tracked. Acoustic receivers set up in an array...

  17. A High-Grade Chondrosarcoma of Calcaneum Mimicking as a Benign Pathology: Delayed Diagnosis and Management.

    Science.gov (United States)

    Baba, Muzamil Ahmad; Nazir, Naila; Shabeer, Maajid; Mir, Bashir Ahmed; Kawoosa, Altaf Ahmad

    2016-10-01

    This case is presented to highlight a rare case of chondrosarcoma of calcaneum in a young adult mimicking as a benign pathology and to highlight the diagnosis and early management of such cases to prevent complications and even death. Chondrosarcoma constitutes less than 10% of all primary malignancies of bone and occurs mostly in proximal locations such as pelvis, proximal femur, and proximal humerus. We present a case of high-grade chondrosarcoma at a very rare site, calcaneum of a 40-year-old male that was mimicking as a benign pathology. This case report highlights the importance of proper clinical examination, evaluation, and suspicion for benign occurring lesions to prevent complications related to a delay in diagnosis. Therapeutic, Level IV: Case study. © 2016 The Author(s).

  18. Acoustic non-diffracting Airy beam

    International Nuclear Information System (INIS)

    Lin, Zhou; Guo, Xiasheng; Tu, Juan; Ma, Qingyu; Wu, Junru; Zhang, Dong

    2015-01-01

    The acoustic non-diffracting Airy beam as its optical counterpart has unique features of self-bending and self-healing. The complexity of most current designs handicaps its applications. A simple design of an acoustic source capable of generating multi-frequency and broad-band acoustic Airy beam has been theoretically demonstrated by numerical simulations. In the design, a piston transducer is corrugated to induce spatial phase variation for transducing the Airy function. The piston's surface is grooved in a pattern that the width of each groove corresponds to the half wavelength of Airy function. The resulted frequency characteristics and its dependence on the size of the piston source are also discussed. This simple design may promote the wide applications of acoustic Airy beam particularly in the field of medical ultrasound

  19. PVT Degradation Studies: Acoustic Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Gerges [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smith, Philip J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-01

    Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. This document reports on a study of acoustic techniques to determine whether they can provide a diagnostic for the fogging of PVT. Different ultrasound techniques were employed for detecting the level of internal fogging in PVT, including wave velocity measurements, attenuation, nonlinear acoustics, and acoustic microscopy. The results indicate that there are linear relations between the wave velocity and wave attenuation with the level of internal fogging. The effects of fogging on ultrasound wave attenuation is further verified by acoustic microscopy imaging, where regions with fog in the specimen demonstration higher levels of attenuation compared to clear regions. Results from the nonlinear ultrasound measurements were inconclusive due to high sensitivities to transducer coupling and fixture variabilities.

  20. Ewing's sarcoma mimicking a meningioma in radiological findings: a case report

    International Nuclear Information System (INIS)

    Kwon, Hee Jin; Choi, Sun Seob

    2007-01-01

    Ewing's sarcoma is an uncommon primary bone tumor. Primary Ewing's sarcoma of the cranium is extremely rare and constitutes only 1% of all Ewing's sarcoma cases. Usually, primary Ewing's sarcoma of the carnium manifests as an expansile osteolytic malignant bone tumor with or without intracranial extension. We report here the radiological findings of a case of Ewing's sarcoma mimicking a meningioma in an 18-year-old man