Geochemical modeling of magmatic gas scrubbing
Directory of Open Access Journals (Sweden)
B. Gambardella
2005-06-01
Full Text Available The EQ3/6 software package, version 7.2 was successfully used to model scrubbing of magmatic gas by pure water at 0.1 MPa, in the liquid and liquid-plus-gas regions. Some post-calculations were necessary to account for gas separation effects. In these post-calculations, redox potential was considered to be fixed by precipitation of crystalline a-sulfur, a ubiquitous and precocious process. As geochemical modeling is constrained by conservation of enthalpy upon water-gas mixing, the enthalpies of the gas species of interest were reviewed, adopting as reference state the liquid phase at the triple point. Our results confirm that significant emissions of highly acidic gas species (SO2(g, HCl(g, and HF(g are prevented by scrubbing, until dry conditions are established, at least locally. Nevertheless important outgassing of HCl(g can take place from acid, HCl-rich brines. Moreover, these findings support the rule of thumb which is generally used to distinguish SO2-, HCl-, and HF-bearing magmatic gases from SO2-, HCl-, and HF-free hydrothermal gases.
Simultaneous stack-gas scrubbing and waste water treatment
Poradek, J. C.; Collins, D. D.
1980-01-01
Simultaneous treatment of wastewater and S02-laden stack gas make both treatments more efficient and economical. According to results of preliminary tests, solution generated by stack gas scrubbing cycle reduces bacterial content of wastewater. Both processess benefit by sharing concentrations of iron.
Temperature impact on SO2 removal efficiency by ammonia gas scrubbing
International Nuclear Information System (INIS)
He Boshu; Zheng Xianyu; Wen Yan; Tong Huiling; Chen Meiqian; Chen Changhe
2003-01-01
Emissions reduction in industrial processes, i.e. clean production, is an essential requirement for sustainable development. Fossil fuel combustion is the main emission source for gas pollutants, such as NO X , SO 2 and CO 2 , and coal is now a primary energy source used worldwide with coal combustion being the greatest atmospheric pollution source in China. This paper analyzes flue gas cleaning by ammonia scrubbing (FGCAS) for power plants to remove gaseous pollutants, such as NO X , SO 2 and CO 2 , and presents the conceptual zero emission design for power plants. The byproducts from the FGCAS process can be used in agriculture or for gas recovery. Experimental results presented for SO 2 removal from the simulated flue gas in a continuous flow experiment, which was similar to an actual flue gas system, showed that the effectiveness of the ammonia injection or scrubbing depends on the temperature. The FGCAS process can effectively remove SO 2 , but the process temperature should be below 60 deg. C or above 80 deg. C for SO 2 reduction by NH 3 scrubbing
Analysis of Sustainable Technologies for Acid Gas Removal
Dal Pozzo, Alessandro
2017-01-01
Acid gases, such as sulphur dioxide and hydrogen halides and – in a broad sense – carbon dioxide, are typical pollutants generated by combustion processes. Their removal by means of solid sorbents represent an efficient and cost-effective approach in dry acid gas treatment systems for waste incineration flue gas, while for CO2 capture the process is exploratively studied as a promising alternative to amine scrubbing. The present study addressed both aspects. In waste incineration flue gas ...
Aerosol Scrubbing Performance Test for Self-Priming Scrubbing Nozzle Submerged in Water Pool
Energy Technology Data Exchange (ETDEWEB)
Lee, Doo Yong; Jung, Woo Young; Lee, Hyun Chul; Lee, Jong Chan; Kim, Gyu Tae; Song, Yong Jae [FNC Technology Co., Yongin (Korea, Republic of)
2016-10-15
A scrubbing nozzle is one of the key components for a wet scrubber process based Containment Filtered Venting System (CFVS). As a part of a development of Korean CFVS, a self-priming scrubbing nozzle shown in Fig. 1 has been developed based on the well-known venturi scrubber concept. The thermal-hydraulic performances such as the pressure drop across the nozzle, water suction behavior and droplet generation inside throat have been tested in the non-submerged condition as well as submerged condition. The self-priming scrubbing nozzle used for the wet scrubber based CFVS has been developed, which is submerged in the water pool. When there is gas flow at the inlet of the nozzle, the pool water is passively sucked from the water suction slit. The fine droplets generated inside the throat capture the aerosol particles and is discharged into the water pool. In the water pool, the pool scrubbing happens. The aerosol scrubbing performance tests for the developed self-priming scrubbing nozzle has been conducted under the operational conditions such as different aerosol sizes, different carrier gas steam fractions, different, different pool water level and nozzle inlet pressure. The major findings are as follows. (1) Aerosol scrubbing efficiency increases with the increase of the aerosol size. (2) Aerosol scrubbing efficiency increases with the increase of the carrier gas steam fraction. (3) Aerosol scrubbing.
Aerosol Scrubbing Performance Test for Self-Priming Scrubbing Nozzle Submerged in Water Pool
International Nuclear Information System (INIS)
Lee, Doo Yong; Jung, Woo Young; Lee, Hyun Chul; Lee, Jong Chan; Kim, Gyu Tae; Song, Yong Jae
2016-01-01
A scrubbing nozzle is one of the key components for a wet scrubber process based Containment Filtered Venting System (CFVS). As a part of a development of Korean CFVS, a self-priming scrubbing nozzle shown in Fig. 1 has been developed based on the well-known venturi scrubber concept. The thermal-hydraulic performances such as the pressure drop across the nozzle, water suction behavior and droplet generation inside throat have been tested in the non-submerged condition as well as submerged condition. The self-priming scrubbing nozzle used for the wet scrubber based CFVS has been developed, which is submerged in the water pool. When there is gas flow at the inlet of the nozzle, the pool water is passively sucked from the water suction slit. The fine droplets generated inside the throat capture the aerosol particles and is discharged into the water pool. In the water pool, the pool scrubbing happens. The aerosol scrubbing performance tests for the developed self-priming scrubbing nozzle has been conducted under the operational conditions such as different aerosol sizes, different carrier gas steam fractions, different, different pool water level and nozzle inlet pressure. The major findings are as follows. (1) Aerosol scrubbing efficiency increases with the increase of the aerosol size. (2) Aerosol scrubbing efficiency increases with the increase of the carrier gas steam fraction. (3) Aerosol scrubbing
Electro-scrubbing volatile organic carbons in the air stream with a gas diffusion electrode
Energy Technology Data Exchange (ETDEWEB)
Yang Ji, E-mail: yangji@ecust.edu.cn [School of Resources and Environmental Engineering, State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, East China University of Science and Technology, Shanghai 200237 (China); School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Liu Kaichen; Jia Jinping; Cao Limei [School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China)
2011-04-15
It is demonstrated that exposing the VOC air streams to the electro-scrubbing reactor with a gas diffusion electrode leads to an efficient removal of organics. The importance order of the influence factors on the electro-scrubbing reactor performance is: conductivity, voltage and air stream flow-rate. The effective conductivity and high voltages generally are beneficial to the removal process and the air flow-rate is not a significant factor compared with the other two, indicating that the reactor might have a consistently satisfying performance within a wide range of gas volumetric load. The mass transfer of both organics and oxygen in the reactor is estimated by mathematical model, and the calculation determines the concentration boundary conditions for the 2-ethoxyethyl acetate removal: if the 2-ethoxyethyl acetate concentration in the inflow air stream holds C{sub G,i} {<=} 0.7198 % , the removal in the electro-scrubbing reactor is electrochemical reaction controlled; if C{sub G,i} > 0.7198 % , the controlling step will be the oxygen mass transfer from the air to the liquid in the electro-scrubbing reactor. The Apparent Current Efficiency of the electro-scrubbing reactor was also determined using COD data, which is significantly higher than some commercial metal oxide electrodes, showing that the reactor is energy efficient and has the promise for the future scale-up.
NOx retention in scrubbing column
International Nuclear Information System (INIS)
Nakazone, A.K.; Costa, R.E.; Lobao, A.S.T.; Matsuda, H.T.; Araujo, B.F.
1988-07-01
During the UO 2 dissolution in nitric acid, some different species of NO x are released. The off gas can either be refluxed to the dissolver or be released and retained on special columns. The final composition of the solution is the main parameter to take in account. A process for nitrous gases retention using scubber columns containing H 2 O or diluted HNO 3 is presented. Chemiluminescence measurement was employed to NO x evalution before and after scrubbing. Gas flow, temperature, residence time are the main parameters considered in this paper. For the dissolution of 100g UO 2 in 8M nitric acid, a 6NL/h O 2 flow was the best condition for the NO/NO 2 oxidation with maximum adsorption in the scrubber columns. (author) [pt
Dynawave froth scrubbing technology
International Nuclear Information System (INIS)
McLean, J.E.
1989-01-01
The DynaWave family of scrubbers was developed and patented by DuPont in the 1970's and is used extensively within the company. Because the technology was treated as confidential, information about the scrubbers was not published outside of DuPont. In 1986 Monsanto Enviro-Chem was asked to install a Reverse Jet scrubber at DuPont's Burnside spent acid recovery pant to replace an aging spray humidifying tower. Enviro-Chem was impressed with the technology and entered into a licensing agreement with DuPont in late 1987. This paper addresses the application of DynaWave froth scrubbing technology to metallurgical plant process and effluent gas streams. Froth scrubber design principles an sampling results from pilot plant trails on fluid bed roaster off-gas are presented
Impurity of Sulfur Layers and Magmatic Gas Scrubbing: Implications for Gas Monitoring
Scolamacchia, T.
2017-12-01
The evidence of bodies of elemental sulfur (Se) beneath acid crater lakes at the summit of composite active volcanoes has been recognized several decades ago (Oppenheimer and Stevenson, 1989; Christenson and Woods, 1993). But Se accumulation was already hypothesized a century ago at Kusatzu Shirane (Japan) based on the observation of sulfur spherules floating on its crater-lake (Ohashi, 1919). Since these pioneering works, other studies have focused on understanding key aspects of molten sulfur bodies, considered a feature unique of volcanic lakes. Instead, it is reasonable to assume that Se bodies occur in several volcanic settings because a) several reactions may lead to Se deposition from S-bearing gases, and b) crater-lakes, surface expressions of hydrothermal systems, are transient features. The scrubbing of several magmatic gases, some of which critical for volcano monitoring, has been attributed to ground/surface waters (Symonds et al. 2001). Nevertheless, gas scrubbing could reflect viscosity variations of impure Se within hydrothermal systems. Industrial experiments indicated that impurities (organics, H2S, ammonia, HCl, HF, HBr, HI) hinder Se polymerization at T ≥ 160ºC, allowing viscosity to remain low for long time depending on the maximum T achieved and heating rates (Bacon and Fanelli, 1943). However, a prolonged heating destroys the viscosity-modifying substances (e.g. H2Sx formed by reactions with organics, H2S, or ammonia) and dramatic Se viscosity increases occur after a certain number of heating and cooling cycles. A prolonged boiling of Se with organics was observed to release H2S, following H2Sx disruption. Some gases (e.g. SO2) do not affect Se viscosity. In volcanic environments gases such as SO2, CO2 could escape under Selow viscosity regimes. Also, halogens absence in gas emissions could be caused by their participation in reactions within S-layers causing its viscosity to remain low. More data are needed to validate the hypothesis
International Nuclear Information System (INIS)
Judd, M.S.; Van Cleve, J.E. Jr.; Rainey, W.T. Jr.
1976-11-01
During the refabrication of high-temperature gas-cooled reactor (HTGR) fuel, perchloroethylene (C 2 Cl 4 ) is used as the nonmoderating scrubbing medium to remove condensable hydrocarbons, carbon soot, and uranium-bearing particulates from the off-gas streams. The process by which the contaminated perchloroethylene is recycled is discussed
Energy Technology Data Exchange (ETDEWEB)
Judd, M.S.; Van Cleve, J.E. Jr.; Rainey, W.T. Jr.
1976-11-01
During the refabrication of high-temperature gas-cooled reactor (HTGR) fuel, perchloroethylene (C/sub 2/Cl/sub 4/) is used as the nonmoderating scrubbing medium to remove condensable hydrocarbons, carbon soot, and uranium-bearing particulates from the off-gas streams. The process by which the contaminated perchloroethylene is recycled is discussed.
Estimated effects of interfacial vaporization on fission product scrubbing
International Nuclear Information System (INIS)
Moody, F.J.; Nagy, S.G.
1983-01-01
When bubbles containing non-condensible gas rise through a water pool, interfacial evaporation causes a flow of vapor into the bubbles. The inflow reduces the outward particle motion toward the bubble wall, diminishing the effectiveness of fission product particle removal. This analysis provides an estimate of evaporation on pool scrubbing effectiveness. It is shown that hot gas, which boils water at the bubble wall, reduces the effective scrubbing height by less than five centimeters. Although the evaporative humidification in a rising bubble containing non-condensible gas has a diminishing effect on scrubbing mechanisms, substantial decontamination is still expected even for the limiting case of a saturated pool
Estimated effects of interfacial vaporization on fission product scrubbing: Chapter 11
International Nuclear Information System (INIS)
Moody, F.J.; Nagy, S.G.
1983-01-01
When bubbles containing non-condensible gas rise through a water pool, interfacial evaporation causes a flow of vapor into the bubbles. The inflow reduces the outward particle motion toward the bubble wall, diminishing the effectiveness of fission product particle removal. This analysis provides an estimate of evaporation on pool scrubbing effectiveness. It is shown that hot gas, which boils water at the bubble wall, reduces the effective scrubbing height by less than five centimeters. Although the evaporative humidification in a rising bubble containing non-condensible gas has a diminishing effect on scrubbing mechanisms, substantial decontamination is still expected even for the limiting case of a saturated pool
Clear Liquor Scrubbing with Anhydrite Production
International Nuclear Information System (INIS)
Hargrove, O. W.; Carey, T. R.; Lowell, P. S.; Meserole, F. B.; Rhudy, R. G.; Feeley, Thomas J.
1997-01-01
The objective of this project to develop an advanced flue gas desulfurization (FGD) process that has decreased capital and operating costs, higher SO 2 removal efficiency, and better by-product solids quality than existing, commercially available technology. A clear liquor process (which uses a scrubbing liquid with no solids) will be used to accomplish this objective rather than a slurry liquor process (which contains solids). This clear liquor scrubbing (CLS) project is focused on three research areas: (1) Development of a clear liquor scrubbing process that uses a clear solution to remove SO 2 from flue gas and can be operated under inhibited-oxidation conditions; (2) Development of an anhydrite process that converts precipitated calcium sulfite to anhydrous calcium sulfate (anhydrite); and (3) Development of an alkali/humidification process to remove HCl from flue gas upstream of the FGD system. The anhydrite process also can be retrofit into existing FGD systems to produce a valuable by-product as an alternative to gypsum. This fits well into another of FETC's PRDA objectives of developing an advanced byproduct recovery subsystem capable of transforming SO 2 into a useable byproduct or high-volume valuable commodities of interest. This paper describes the proposed processes, outlines the test approach, and preliminary Phase I test results
Thermal-Hydraulic Performance of Scrubbing Nozzle Used for CFVS
Energy Technology Data Exchange (ETDEWEB)
Lee, Hyun Chul; Lee, Doo Yong; Jung, Woo Young; Lee, Jong Chan; Kim, Gyu Tae [FNC TECH, Yongin (Korea, Republic of)
2016-05-15
A Containment Filtered Venting System (CFVS) is the most interested device to mitigate a threat against containment integrity under the severe accident of nuclear power plant by venting with the filtration of the fission products. FNC technology and partners have been developed the self-priming scrubbing nozzle used for the CFVS which is based on the venturi effect. The thermal-hydraulic performances such as passive scrubbing water suction as well as pressure drop across the nozzle have been tested under various thermal-hydraulic conditions. The two types of test section have been built for testing the thermal-hydraulic performance of the self-priming scrubbing nozzle. Through the visualization loop, the liquid suction performance through the slit, pressure drop across the nozzle are measured. The passive water suction flow through the suction slit at the throat is important parameter to define the scrubbing performance of the self-priming scrubbing nozzle. The water suction flow is increased with the increase of the overhead water level at the same inlet gas flow. It is not so much changed with the change of inlet gas flow at the overhead water level.
Chang, Moo Been; Lee, How Ming; Wu, Feeling; Lai, Chi Ren
2004-08-01
Oxides of nitrogen (NOx) [nitrogen oxide (NO) + nitrogen dioxide (NO2)] and sulfur dioxide (SO2) are removed individually in traditional air pollution control technologies. This study proposes a combined plasma scrubbing (CPS) system for simultaneous removal of SO2 and NOx. CPS consists of a dielectric barrier discharge (DBD) and wet scrubbing in series. DBD is used to generate nonthermal plasmas for converting NO to NO2. The water-soluble NO2 then can be removed by wet scrubbing accompanied with SO2 removal. In this work, CPS was tested with simulated exhausts in the laboratory and with diesel-generator exhausts in the field. Experimental results indicate that DBD is very efficient in converting NO to NO2. More than 90% removal of NO, NOx, and SO2 can be simultaneously achieved with CPS. Both sodium sulfide (Na2S) and sodium sulfite (Na2SO3) scrubbing solutions are good for NO2 and SO2 absorption. Energy efficiencies for NOx and SO2 removal are 17 and 18 g/kWh, respectively. The technical feasibility of CPS for simultaneous removal of NO, NO2, and SO2 from gas streams is successfully demonstrated in this study. However, production of carbon monoxide as a side-product (approximately 100 ppm) is found and should be considered.
Pool scrubbing models for iodine components
Energy Technology Data Exchange (ETDEWEB)
Fischer, K [Battelle Ingenieurtechnik GmbH, Eschborn (Germany)
1996-12-01
Pool scrubbing is an important mechanism to retain radioactive fission products from being carried into the containment atmosphere or into the secondary piping system. A number of models and computer codes has been developed to predict the retention of aerosols and fission product vapours that are released from the core and injected into water pools of BWR and PWR type reactors during severe accidents. Important codes in this field are BUSCA, SPARC and SUPRA. The present paper summarizes the models for scrubbing of gaseous Iodine components in these codes, discusses the experimental validation, and gives an assessment of the state of knowledge reached and the open questions which persist. The retention of gaseous Iodine components is modelled by the various codes in a very heterogeneous manner. Differences show up in the chemical species considered, the treatment of mass transfer boundary layers on the gaseous and liquid sides, the gas-liquid interface geometry, calculation of equilibrium concentrations and numerical procedures. Especially important is the determination of the pool water pH value. This value is affected by basic aerosols deposited in the water, e.g. Cesium and Rubidium compounds. A consistent model requires a mass balance of these compounds in the pool, thus effectively coupling the pool scrubbing phenomena of aerosols and gaseous Iodine species. Since the water pool conditions are also affected by drainage flow of condensate water from different regions in the containment, and desorption of dissolved gases on the pool surface is determined by the gas concentrations above the pool, some basic limitations of specialized pool scrubbing codes are given. The paper draws conclusions about the necessity of coupling between containment thermal-hydraulics and pool scrubbing models, and proposes ways of further simulation model development in order to improve source term predictions. (author) 2 tabs., refs.
Pool scrubbing models for iodine components
International Nuclear Information System (INIS)
Fischer, K.
1996-01-01
Pool scrubbing is an important mechanism to retain radioactive fission products from being carried into the containment atmosphere or into the secondary piping system. A number of models and computer codes has been developed to predict the retention of aerosols and fission product vapours that are released from the core and injected into water pools of BWR and PWR type reactors during severe accidents. Important codes in this field are BUSCA, SPARC and SUPRA. The present paper summarizes the models for scrubbing of gaseous Iodine components in these codes, discusses the experimental validation, and gives an assessment of the state of knowledge reached and the open questions which persist. The retention of gaseous Iodine components is modelled by the various codes in a very heterogeneous manner. Differences show up in the chemical species considered, the treatment of mass transfer boundary layers on the gaseous and liquid sides, the gas-liquid interface geometry, calculation of equilibrium concentrations and numerical procedures. Especially important is the determination of the pool water pH value. This value is affected by basic aerosols deposited in the water, e.g. Cesium and Rubidium compounds. A consistent model requires a mass balance of these compounds in the pool, thus effectively coupling the pool scrubbing phenomena of aerosols and gaseous Iodine species. Since the water pool conditions are also affected by drainage flow of condensate water from different regions in the containment, and desorption of dissolved gases on the pool surface is determined by the gas concentrations above the pool, some basic limitations of specialized pool scrubbing codes are given. The paper draws conclusions about the necessity of coupling between containment thermal-hydraulics and pool scrubbing models, and proposes ways of further simulation model development in order to improve source term predictions. (author) 2 tabs., refs
Directory of Open Access Journals (Sweden)
Amy G Rapsang
2013-01-01
Full Text Available Scrub typhus is an acute febrile illness caused by orientia tsutsugamushi, transmitted to humans by the bite of the larva of trombiculid mites. It causes a disseminated vasculitic and perivascular inflammatory lesions resulting in significant vascular leakage and end-organ injury. It affects people of all ages and even though scrub typhus in pregnancy is uncommon, it is associated with increased foetal loss, preterm delivery, and small for gestational age infants. After an incubation period of 6-21 days, onset is characterized by fever, headache, myalgia, cough, and gastrointestinal symptoms. A primary papular lesion which later crusts to form a flat black eschar, may be present. If untreated, serious complications may occur involving various organs. Laboratory studies usually reveal leukopenia, thrombocytopenia, deranged hepatic and renal function, proteinuria and reticulonodular infiltrate. Owing to the potential for severe complications, diagnosis, and decision to initiate treatment should be based on clinical suspicion and confirmed by serologic tests. A therapeutic trial of tetracycline or chloramphenicol is indicated in patients in whom the diagnosis of scrub typhus is suspected. The recommended treatment regimen for scrub typhus is doxycycline. Alternative regimens include tetracycline, chloramphenicol, azithromycin, ciprofloxacin, rifampicin, and roxithromycin. Treatment of pregnant women with azithromycin was successfully done without relapse and with favorable pregnancy outcomes. Hence, early diagnosis and treatment are essential in order to reduce the mortality and the complications associated with the disease. We searched the English-language literature for reports of scrub typhus in children, pregnant women, and non-pregnant patients with scrub typhus, using the MEDLINE/PubMed database, which includes citations from 1945 to the present time. We used the search terms ′scrub typhus′, ′scrub typhus′ and ′pregnancy′, ′scrub
Improved Purex solvent scrubbing methods
International Nuclear Information System (INIS)
Mailen, J.C.; Tallent, O.K.
1984-01-01
Studies of hydrazine and hydroxylamine salts as solvent scrubbing agents that can be decomposed into gases are summarized. Results from testing of countercurrent scrubbers and solid sorber columns that produce lesser amounts of permanent salts are reported. The status of studies of the acid-degradation of paraffin diluent and the options for removal of long-chain organic acids is given
Separation of iodine from mercury containing scrubbing solutions
Burger, Leland L.; Scheele, Randall D.
1979-01-01
Radioactive iodines can be recovered from a nitric acid scrub solution containing mercuric nitrate by passing a current through the scrub solution to react the iodine with the mercuric nitrate to form mercuric iodate which precipitates out. The mercuric iodate can then be reacted to recover the radioiodine for further processing into a form suitable for long-term storage and to recover the mercury for recycling.
Deshwal, Bal Raj; Jin, Dong Seop; Lee, Si Hyun; Moon, Seung Hyun; Jung, Jong Hyeon; Lee, Hyung Keun
2008-02-11
The present study attempts to clean up nitric oxide from the simulated flue gas using aqueous chlorine-dioxide solution in the bubbling reactor. Chlorine-dioxide is generated by chloride-chlorate process. Experiments are carried out to examine the effect of various operating variables like input NO concentration, presence of SO(2), pH of the solution and NaCl feeding rate on the NO(x) removal efficiency at 45 degrees C. Complete oxidation of nitric oxide into nitrogen dioxide occurred on passing sufficient ClO(2) gas into the scrubbing solution. NO is finally converted into nitrate and ClO(2) is reduced into chloride ions. A plausible reaction mechanism concerning NO(x) removal by ClO(2) is suggested. DeNO(x) efficiency increased slightly with the increasing input NO concentration. The presence of SO(2) improved the NO(2) absorption but pH of solution showed marginal effect on NO(2) absorption. NO(x) removal mechanism changed when medium of solution changed from acidic to alkaline. A constant NO(x) removal efficiency of about 60% has been achieved in the wide pH range of 3-11 under optimized conditions.
Influence of liquid and gas flow rates on sulfuric acid mist removal from air by packed bed tower
Directory of Open Access Journals (Sweden)
Jafari Mohammad Javad
2012-12-01
Full Text Available Abstract The possible emission of sulfuric acid mists from a laboratory scale, counter-current packed bed tower operated with a caustic scrubbing solution was studied. Acid mists were applied through a local exhaust hood. The emissions from the packed bed tower were monitored in three different categories of gas flow rate as well as three liquid flow rates, while other influencing parameters were kept almost constant. Air sampling and sulfuric acid measurement were carried out iso-kinetically using USEPA method 8. The acid mists were measured by the barium-thorin titration method. According to the results when the gas flow rate increased from 10 L/s to 30 L/s, the average removal efficiency increased significantly (p 3, respectively. L/G of 2–3 was recommended for designing purposes of a packed tower for sulfuric acid mists and vapors removal from contaminated air stream.
International Nuclear Information System (INIS)
Ziegler, D.L.
1975-01-01
A system is described for treating or cleaning incinerator flue gas containing acid gases and radioactive and fissionable contaminants. Flue gas and a quench solution are fed into a venturi and then tangentially into the lower portion of a receptacle for restricting volumetric content of the solution. The upper portion of the receptacle contains a scrub bed to further treat or clean the flue gas
Experimental evidence of nitrous acid formation in the electron beam treatment of flue gas
International Nuclear Information System (INIS)
Maetzing, H.; Namba, H.; Tokunaga, O.
1994-01-01
In the Electron Beam Dry Scrubbing (EBDS) process, flue gas from fossil fuel burning power plants is irradiated with accelerated (300-800 keV) electrons. Thereby, nitrogen oxide (NO x ) and sulfur dioxide (SO 2 ) traces are transformed into nitric and sulfuric acids, respectively, which are converted into particulate ammonium nitrate and sulfate upon the addition of ammonia. The powdery product can be filtered from the main gas stream and can be sold as agricultural fertilizer. A lot of experimental investigations have been performed on the EBDS process and computer models have been developed to interpret the experimental results and to predict economic improvements. According to the model calculations, substantial amounts of intermediate nitrous acid (HNO 2 ) are formed in the electron beam treatment of flue gas. The first experimental investigation about the formation of nitrous acid in an irradiated mixture of NO in synthetic air has been undertaken. Under these conditions, aerosol formation is avoided. UV spectra of the irradiated gas were recorded in the wavelength range λ = 345-375 nm. Both NO 2 and HNO 2 have characteristic absorption bands in this wavelength range. Calibration spectra of NO 2 were subtracted from the sample spectra. The remaining absorption bands can clearly be assigned to nitrous acid. The concentration of nitrous acid was determined by differential optical absorption. It was found lower than the model prediction. The importance of nitrous acid formation in the EBDS process needs to be clarified. (author)
Haja Mohideen, Mohamed Infas; Pillai, Renjith S.; Adil, Karim; Bhatt, Prashant; Belmabkhout, Youssef; Shkurenko, Aleksander; Maurin, Guillaume; Eddaoudi, Mohamed
2017-01-01
Summary The development of highly stable separation agents is recognized as a decisive step toward the successful deployment of energy-efficient and cost-effective separation processes. Here, we report the synthesis and construction of a metal-organic framework (MOF), kag-MOF-1, that has adequate structural and chemical features and affords a stable adsorbent with unique and appropriate adsorption properties for gas processing akin to acid gas removal, dehydration, and benzene-toluene-xylene (BTX) sieving. A combination of X-ray diffraction experiments, adsorption studies, mixed-gas breakthrough adsorption column testing, calorimetric measurements, and molecular simulations corroborated the exceptional separation performance of kag-MOF-1 and its prospective use as a multifunctional adsorbent. The unique adsorption properties of kag-MOF-1, resulting from the contracted pore system with aligned periodic array of exposed functionalities, attest to the prominence of this new generation of ultra-microporous material as a prospective practical adsorbent toward cost-effective and more simplified gas and vapor processing flowcharts for natural gas upgrading and flue gas scrubbing.
Haja Mohideen, Mohamed Infas
2017-10-19
Summary The development of highly stable separation agents is recognized as a decisive step toward the successful deployment of energy-efficient and cost-effective separation processes. Here, we report the synthesis and construction of a metal-organic framework (MOF), kag-MOF-1, that has adequate structural and chemical features and affords a stable adsorbent with unique and appropriate adsorption properties for gas processing akin to acid gas removal, dehydration, and benzene-toluene-xylene (BTX) sieving. A combination of X-ray diffraction experiments, adsorption studies, mixed-gas breakthrough adsorption column testing, calorimetric measurements, and molecular simulations corroborated the exceptional separation performance of kag-MOF-1 and its prospective use as a multifunctional adsorbent. The unique adsorption properties of kag-MOF-1, resulting from the contracted pore system with aligned periodic array of exposed functionalities, attest to the prominence of this new generation of ultra-microporous material as a prospective practical adsorbent toward cost-effective and more simplified gas and vapor processing flowcharts for natural gas upgrading and flue gas scrubbing.
Comparative scrub solution tests for decontamination of transuranic radionuclides from soils
International Nuclear Information System (INIS)
Stevens, J.R.; Kochen, R.L.; Rutherford, D.W.; Riordan, G.A.; Delaney, I.C.
1982-08-01
Soil decontamination tests were done using three scrubbing solutions on five different transuranic-contaminated soils from Department of Energy sites. The soils came from Rocky Flats, Colorado; Hanford, Washington; Mound Facility, Ohio; Idaho National Engineering Laboratory, Idaho; and Los Alamos National Laboratory, New Mexico. Decontamination was effected by physical and chemical means. A pH 12.5 scrub effected decontamination by serving as a hydraulic grading and attrition scrub medium; this solution did not solubilize the actinide contamination. A 2% HNO 3 , 0.2% HF, 2% pine oil, and 5% Calgon solution effected decontamination by physical and chemical means; this solution solubilized particulate actinide and actinide dispersed on the surface of soil particles. A 2N HCl scrub was also used to effect decontamination by physical and chemical means; this reagent solubilized soil constituents, removing contamination that had migrated into mineral surfaces. Only Rocky Flats soil was effectively decontaminated by the high pH solution although all soils had an enrichment of the activity in the -150 mesh fraction. Attrition scrubbing with both acid solutions had a better decontamination ability for the +150 mesh fraction for Hanford, INEL, and LANL soils. In addition, the acid solutions solubilized some of the plutonium and had a decontamination effect on the fine fractions
Simulation of pool scrubbing experiments using BUSCA
International Nuclear Information System (INIS)
Dehbi, A.; Guentay, S.
1994-01-01
BUSCA-PSI is a computer code which predicts the aerosol scrubbing taking place when gas bubbles containing fission products rise through stagnant pools of water after a postulated severe accident. A Lagrangian formulation is adopted to follow the path of a bubble as it rises toward the surface of the pool. The BUSCA model includes most aerosol removal mechanisms which are thought to be significant, namely: Jet Impaction at tile orifice, Convection/Diffusiophoresis during steam condensation, Thermophoresis, Sedimentation, Centrifugal Impaction during bubble rise, and Brownian Diffusion. The hydraulic modelling offers a variety of options for the initial globule volume, the stable bubble size, tile bubble rise velocity, and the bubble shape. The heat and mass transfer part of tile model uses correlations found in the relevant literature. BUSCA simulations were performed to determine the decontamination factor (DF) dependence on key aerosol and thermal hydraulic parameters. The decontamination factor increases with height, pool temperature subcooling, and steam content. The decontamination factor exhibits a parabolic dependence on the particle radius. At low particle sizes, the DF is high due to Brownian Diffusion which is the dominant removal mechanism. The DF hits a minimum and then increases with particle size as Centrifugal Impaction and Sedimentation become important. In separate calculations, BUSCA was used to the simulate the aerosol scrubbing experiments performed by EPRI. For cold pool tests, the predicted scrubbing efficiencies were in a good, conservative agreement with the data for both Tin and CsI, and the discrepancies were within the reported measurement errors. For hot pool tests, the code systematically underpredicted the scrubbing DF's; this is potentially due to condensation in the gas space above the pool, a situation not currently modelled by BUSCA. The code was also tested against data produced by the Tepco-Toshiba-Hitachi experiments. The
Multi-component removal in flue gas by aqua ammonia
Yeh, James T [Bethel Park, PA; Pennline, Henry W [Bethel Park, PA
2007-08-14
A new method for the removal of environmental compounds from gaseous streams, in particular, flue gas streams. The new method involves first oxidizing some or all of the acid anhydrides contained in the gas stream such as sulfur dioxide (SO.sub.2) and nitric oxide (NO) and nitrous oxide (N.sub.2O) to sulfur trioxide (SO.sub.3) and nitrogen dioxide (NO.sub.2). The gas stream is subsequently treated with aqua ammonia or ammonium hydroxide which captures the compounds via chemical absorption through acid-base or neutralization reactions. The products of the reactions can be collected as slurries, dewatered, and dried for use as fertilizers, or once the slurries have been dewatered, used directly as fertilizers. The ammonium hydroxide can be regenerated and recycled for use via thermal decomposition of ammonium bicarbonate, one of the products formed. There are alternative embodiments which entail stoichiometric scrubbing of nitrogen oxides and sulfur oxides with subsequent separate scrubbing of carbon dioxide.
Code Development of Radioactive Aerosol Scrubbing in Pool-Injection Zone
Energy Technology Data Exchange (ETDEWEB)
Jo, Hyun Joung; Ha, Kwang Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Jang, Dong Soon [Chungnam National University, Daejeon (Korea, Republic of)
2015-10-15
The pool scrubbing models were reviewed and an aerosol scrubbing code has been prepared to calculate decontamination factor through the injection zone. The developed code has been verified using the experimental results and evaluated parametrically on the input variables. In injection zone, the initial steam condensation was most effective mechanism for the aerosol removal, and the steam fraction and pool temperature were highly affected on the decontamination factor by initial steam condensation. The aerosol scrubbing code will be updated to evaluate the decontamination factor at rise zone and finally whole pool scrubber phenomena. If a severe accident occurs in a nuclear power plant (NPP), the aerosol and gaseous fission products might be produced in the reactor vessel, and then released to the environment after the containment failure. FCVS (Filtered Containment Venting System) is one of the severe accident mitigation systems for retaining the containment integrity by discharging the high-temperature and high-pressure fission products to the environment after passing through the filtration system. In general, the FCVS is categorized into two types, wet and dry types. The scrubbing pool could play an important role in the wet type FCVS because a large amount of aerosol is captured in the water pool. The pool scrubbing phenomena have been modelled and embedded in several computer codes, such as SPARC (Suppression Pool Aerosol Removal Code), BUSCA (BUbble Scrubbing Algorithm) and SUPRA (Suppression Pool Retention Analysis). These codes aim at simulating the pool scrubbing process and estimating the decontamination factors (DFs) of the radioactive aerosol and iodine gas in the water pool, which is defined as the ratio of initial mass of the specific radioactive material to final massy after passing through the water pool. The pool scrubbing models were reviewed and an aerosol scrubbing code has been prepared to calculate decontamination factor through the injection
Directory of Open Access Journals (Sweden)
S D'sa
2012-01-01
Full Text Available Scrub typhus is a mite borne infectious disease caused by Orientia tsutsugamushi. It is a common cause of undifferentiated febrile illness in the Indian subcontinent. We present a case of scrub typhus with a rare ophthalmic manifestation.Our patient presented with fever and opsoclonus, was diagnosed to have scrub typhus and completely improved upon treatment. Opsoclonus complicates various medical diseases, including viral infections, toxin, encephalitis, brain tumors, and paraneoplastic syndromes. There has been only one previously reported case of opsoclonus in scrub typhus. This phenomenon highlights the increasingly complex presentation of common diseases. It also indicates there is much to be discovered about the immunopathogenesis of this infectious disease.
Seawater scrubbing - reduction of SO{sub x} emissions from ship exhausts
Energy Technology Data Exchange (ETDEWEB)
Karle, Ida-Maja; Turner, David (Dept. of Chemistry, Goeteborg Univ. (SE))
2007-07-01
It is shown that seawater scrubbing is a promising technology for reducing sulphur oxide emissions from ships. The marine chemical aspects of shipboard seawater scrubbing have been modelled and analysed, based on a 12 MW engine burning fuel with a 3% sulphur content. Calculations have been made for different efficiencies of sulphur scrubbing, different water temperatures, and for six different water types (open ocean, Kattegatt, Baltic Proper, Bothnian Sea, Bothnian Bay, and river freshwater). The results of the calculations give the volumes of water required for (i) uptake of SO{sub x} (the scrubbing process), (ii) dilution of the scrubbing water to achieve a pH of 6.5, (iii) further dilution to achieve a pH within 0.2 units of that in the ambient water, and no more that a 1% reduction in dissolved oxygen concentration. The volumes of water required for a given efficiency of the scrubbing process increase with decreasing salinity and with increasing water temperature. The salinity dependence is non-linear, such that operation in the Bothnian Sea, Bothnian Bay and low alkalinity river freshwater would require significantly larger water volumes for scrubbing and dilution that operation in the Baltic Proper, Kattegatt or open ocean. The calculations assume access to large volumes of unaffected, ambient water. This is reasonable for a ship under way in open water, but not in enclosed or semi-enclosed waters, which would therefore require detailed case studies. It may be possible to reduce the volumes of dilution water required by, for example, aeration of the scrubbing water and addition of base to neutralise the acidic sulphur oxides. Further studies would be needed in order to assess these options
Temperature dependent fission product removal efficiency due to pool scrubbing
Energy Technology Data Exchange (ETDEWEB)
Uchida, Shunsuke, E-mail: suchida@iae.or.jp [Institute of Applied Energy, 1-14-2, Nishi-Shimbashi, Minato-ku, Tokyo 105-0003 (Japan); Itoh, Ayumi; Naitoh, Masanori; Okada, Hidetoshi; Suzuki, Hiroyuki [Institute of Applied Energy, 1-14-2, Nishi-Shimbashi, Minato-ku, Tokyo 105-0003 (Japan); Hanamoto, Yukio [KAKEN, Inc., 1044, Hori-machi, Mito 310-0903 (Japan); Osakabe, Masahiro [Tokyo University of Marine Science & Technology, Koutou-ku, Tokyo 135-8533 (Japan); Fujikawa, Masahiro [Japan Broadcasting Corporation, 2-2-1, Jinnan, Shibuya-ku, Tokyo 150-8001 (Japan)
2016-03-15
Highlights: • Pool temperature effects on the FP removal were not clearly concluded in the previous publications. • It was confirmed that the removal efficiency decreased with temperature around the boiling point. • A modified empirical formula for FP removal was proposed as a function of sub-cooling temperature. • DF could be predicted with an accuracy within a factor of 2 with the proposed formula. - Abstract: The wet-well of boiling water reactors plays important roles not only to suppress the pressure in the primary containment vessel due to steam scrubbing effects during severe accidents but also to mitigate release of radioactive fission products (FP), aerosols and particulates, into the environment. The effects of steam scrubbing in the wet-well on FP removal have been well studied and reported by changing major parameters determining the removal efficiencies, e.g., aerosol diameters, submergence (depth of scrubbing nozzles) and steam/non-condensable gas volume fraction. Unfortunately, the effects of pool temperature on the FP removal were not clearly concluded in the previous publications, though it would be easily expected that boiling in the pool resulted in reduced aerosol removal efficiency. In order to determine the temperature effects on FP removal efficiency, amounts of cesium in aerosols released from scrubbing pool were measured by changing pool temperature in mini and medium scale scrubbing experiments, and then, it was confirmed that the removal efficiency clearly decreased with temperature around the boiling point. Then, a modified empirical formula to express the FP removal around the boiling point temperature was proposed as a function of sub-cooling temperature by applying the effective steam volume fraction, which was designated as the volume ratio of condensed steam in the pool versus the sum of input steam and non-condensable gas. By comparing the measured removal efficiency with the calculated, it was validated that the
Temperature dependent fission product removal efficiency due to pool scrubbing
International Nuclear Information System (INIS)
Uchida, Shunsuke; Itoh, Ayumi; Naitoh, Masanori; Okada, Hidetoshi; Suzuki, Hiroyuki; Hanamoto, Yukio; Osakabe, Masahiro; Fujikawa, Masahiro
2016-01-01
Highlights: • Pool temperature effects on the FP removal were not clearly concluded in the previous publications. • It was confirmed that the removal efficiency decreased with temperature around the boiling point. • A modified empirical formula for FP removal was proposed as a function of sub-cooling temperature. • DF could be predicted with an accuracy within a factor of 2 with the proposed formula. - Abstract: The wet-well of boiling water reactors plays important roles not only to suppress the pressure in the primary containment vessel due to steam scrubbing effects during severe accidents but also to mitigate release of radioactive fission products (FP), aerosols and particulates, into the environment. The effects of steam scrubbing in the wet-well on FP removal have been well studied and reported by changing major parameters determining the removal efficiencies, e.g., aerosol diameters, submergence (depth of scrubbing nozzles) and steam/non-condensable gas volume fraction. Unfortunately, the effects of pool temperature on the FP removal were not clearly concluded in the previous publications, though it would be easily expected that boiling in the pool resulted in reduced aerosol removal efficiency. In order to determine the temperature effects on FP removal efficiency, amounts of cesium in aerosols released from scrubbing pool were measured by changing pool temperature in mini and medium scale scrubbing experiments, and then, it was confirmed that the removal efficiency clearly decreased with temperature around the boiling point. Then, a modified empirical formula to express the FP removal around the boiling point temperature was proposed as a function of sub-cooling temperature by applying the effective steam volume fraction, which was designated as the volume ratio of condensed steam in the pool versus the sum of input steam and non-condensable gas. By comparing the measured removal efficiency with the calculated, it was validated that the
Neuropsychiatric manifestations of scrub typhus
Directory of Open Access Journals (Sweden)
Sanjay K Mahajan
2017-01-01
Full Text Available Scrub typhus is caused by Orientia tsutsugamushi characterized by focal or disseminated vasculitis and perivasculitis which may involve the lungs, heart, liver, spleen and central nervous system. It was thought to have been eradicated from India. Recently it is being reported from many areas of India. The clinical picture and severity of the symptoms varies widely. The neurological manifestations of scrub typhus are not uncommon but are diverse. Meningoencephalitis is classical manifestation of scrub typhus but cerebellitis, cranial nerve palsies, plexopathy, transverse myelitis, neuroleptic malignant syndrome and Guillan-Barré syndrome are other manifestations reported in literature. The availability of literature on the neurological manifestations of scrub typhus is limited to case reports mainly. This article reviews various neurological manifestations of scrub typhus reported in literature.
Status epilepticus in scrub typhus.
Kalita, Jayantee; Mani, Vinita E; Bhoi, Sanjeev K; Misra, Usha K
2016-07-01
Scrub typhus is an emerging infection, and there is little information about status epilepticus (SE) in scrub typhus. We report the clinical spectrum and outcome of SE in scrub typhus. In a 3-year prospective hospital-based observational study, all scrub typhus patients with SE were included. Scrub typhus was diagnosed by immunochromatography assay. SE was defined if convulsions lasted longer than 5 min. The patients' demographic, clinical, computed tomography (CT), magnetic resonance imaging (MRI), and electroencephalography (EEG) findings were noted. Response to antiepileptic drugs (AEDs) and outcome at 1 month and 1 year were recorded. Between 2012 and 2014, there were 66 patients with scrub typhus admitted with central nervous system (CNS) involvement, 10 (15.2%) of whom had SE (generalized convulsions in 5, secondary generalized in one). The median age of the patients was 34 (range 18-71) years and seven were female. The duration of SE ranged between 10 min and 48 h. SE responded to one AED in five patients, two AEDs in three patients, and more than two AEDs in two patients. Cranial MRI findings were normal. All patients recovered completely with doxycycline by 1 month and AED was withdrawn by 8 months in all. Although 15% patients with scrub typhus may have SE, they have good outcome. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.
Pool scrubbing and hydrodynamic experiment on jet injection regime
Energy Technology Data Exchange (ETDEWEB)
Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.
1995-07-01
Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and
Pool scrubbing and hydrodynamic experiment on jet injection regime
International Nuclear Information System (INIS)
Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.
1995-01-01
Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and
Scrub typhus: Clinical spectrum and outcome.
Venkategowda, Pradeep M; Rao, S Manimala; Mutkule, Dnyaneshwar P; Rao, Mallela V; Taggu, Alai N
2015-04-01
Scrub typhus is one of the differential diagnoses for fever with thrombocytopenia. ARDS associated with Scrub typhus has high morbidity and mortality. To evaluate clinical features, lab values, and outcome in patients with scrub typhus and comparison in patients with or without ARDS. A prospective observational study was conducted on 109 patients with febrile illness and thrombocytopenia during a period of 12 months. All 109 patients were tested with both Immune-chromatography test and Weil felix test. Patients having either Immune-chromatography test/Weil felix test positive have been included and considered as scrub typhus positive whereas negative for both Immune-chromatography and Weil felix test were excluded. Clinical features, lab parameters, and outcome were evaluated in all patients with scrub typhus. Statistical analysis used in this study was T-test. Among 58 patients who were included (After exclusion of 51 patients among total of 109 patients) 34 patients had no ARDS and 24 patients had ARDS. The clinical feature like dyspnoea, cough, low blood pressure (MAPscrub typhus patients group with ARDS. The higher titers of Weil-felix can be correlated with more severe form of disease according to our observation. All 34 Scrub typhus patients without ARDS recovered completely. Among 24 Scrub typhus patients with ARDS, 22 patients recovered, and 2 patients died. Scrub typhus is an important differential diagnosis in a patients having fever with thrombocytopenia. Scrub typhus associated with ARDS has high morbidity and mortality. Early diagnosis and treatment with doxycycline can prevent the occurrence of ARDS.
Koh, Gavin C. K. W.; Maude, Richard J.; Paris, Daniel H.; Newton, Paul N.; Blacksell, Stuart D.
2010-01-01
Scrub typhus is transmitted by trombiculid mites and is endemic to East and Southeast Asia and Northern Australia. The clinical syndrome classically consists of a fever, rash, and eschar, but scrub typhus also commonly presents as an undifferentiated fever that requires laboratory confirmation of
Acute pancreatitis associated with scrub typhus.
Sv, Padmavathi Devi; M, Aruna; Kumar, Anil Cv; Krishna Reddy, Hari; Bl, Sangeetha; Siva Kumar, V
2017-01-01
Scrub typhus, or tsutsugamushi fever, is a zoonosis of rural Asia and the western Pacific islands. The causative organism, Orientia (formerly Rickettsia) tsutsugamushi, is transmitted to humans by the bite of a larval Leptotrombidium mite (chigger). Scrub typhus may have gastrointestinal presentations, such as acute acalculous cholecystitis, duodenal ulcer perforation, peritonitis and gastric ulceration. Acute pancreatitis with scrub typhus has been reported rarely. We report a patient of scrub typhus complicated by acute pancreatitis and acute kidney injury. © The Author(s) 2016.
Acid Gas Removal from Natural Gas with Alkanolamines
DEFF Research Database (Denmark)
Sadegh, Negar
commercially for the removal of acid gas impurities from natural gas. Alkanolamines, simple combinations of alcohols and ammonia, are the most commonly used category of chemical solvents for acid gas capture. This Ph.D. project is aboutthermodynamics of natural gas cleaning process with alkanolamines......Some 40 % of the world’s remaining gas reserves are sour or acid, containing large quantities of CO2 and H2S and other sulfur compounds. Many large oil and gas fields have more than 10 mole % CO2 and H2S content. In the gas processing industry absorption with chemical solvents has been used...... pressure on acid gas solubility was also quantitatively investigated through both experimental and modeling approaches....
Scrub Typhus, Republic of Palau
Demma, Linda J.; McQuiston, Jennifer H.; Nicholson, William L.; Murphy, Staci M.; Marumoto, Pearl; Sengebau-Kingzio, J. Maireng; Kuartei, Stevenson; Durand, A. Mark; Swerdlow, David L.
2006-01-01
Scrub typhus, caused by Orientia tsutsugamushi, is a severe febrile illness transmitted to humans by trombiculid mites, which normally feed on rodents. The first known outbreak of scrub typhus in Palau occurred in 2001 to 2003 among residents of the remote southwest islands. To determine the extent of scrub typhus distribution in Palau, we tested serum samples from humans and rodents for antibodies to O. tsutsugamushi. Of 212 Palau residents surveyed in 2003, 101 (47.6%) had immunoglobulin G ...
Studies in the dissolver off-gas system for a spent FBR fuel reprocessing plant
International Nuclear Information System (INIS)
Heinrich, E.; Huefner, R.; Weirich, F.
1982-01-01
Investigations of possible modifications of the process steps of a dissolver off-gas (DOG) system for a spent FBR fuel reprocessing plant are reported. The following operations are discussed: iodine removal from the fuel solution; behaviour of NOsub(x) and iodine in nitric acid off-gas scrubbers at different temperatures and nitric acid concentrations; iodine desorption from the scrub acid; selective absorption of noble gases in refrigerant-12; cold traps. The combination of suitable procedures to produce a total DOG system is described. (U.K.)
Cooper, C. David
1997-01-01
Emissions of nitrogen oxides NO(x) are a significant problem in the United States. NO(x) are formed in any combustion process, therefore it is not surprising that NO(x) are emitted from the boilers at KSC. Research at UCF has shown (in the laboratory) that injecting H2O2 into hot simulated flue gases can oxidize the NO and NO2 to their acid gas forms, HNO2 and HNO3, respectively. These acid gases are much more water soluble than their counterparts, and theoretically can be removed easily by wet scrubbing. This technology was of interest to NASA, both for their boilers at KSC, and for their combustion sources elsewhere. However, it was necessary to field test the technology and to provide pilot-scale data to aid in design of full-scale facilities. Hence this project was initiated in May of 1996.
Molecular detection of Orientia tsutsugamushi from suspected scrub typhus cases.
Srinivasan, Seethalakshmi; Menon, Thangam
2017-01-01
Scrub typhus is an acute febrile illness caused by Orientia tsutsugamushi. The disease is under-diagnosed in India, because of low index of suspicion and also due to its nonspecific presentation, and lack of confirmatory diagnostic tests. This study was undertaken to diagnose scrub typhus in patients with undifferentiated fevers by serology and molecular methods. A total of 68 blood samples were collected from patients clinically suspected to have scrub typhus. After transportation to the laboratory, the serum was separated from the blood and subjected to rapid card test. The ethylenediaminetetraacetic acid blood samples were subjected to DNA extraction using QIAamp DNA Mini Kit followed by nested polymerase chain reaction (nPCR). 24/68 (35.29%) cases showed the presence of antibody against scrub typhus by serology. 6/68 (8.8%) patients showed the presence of outer membrane protein antigen gene 56 kDa by nPCR. 5/24 serology positive cases showed the presence of 56 kDa outer membrane protein antigen gene by nPCR. A large number of cases positive by serology were negative by PCR which may indicate a low sensitivity of this test either due to low copy numbers or due to excess host DNA. Delay in treatment may increase disease severity and leads to higher mortality. Thus, molecular methods of diagnosis may aid in the early diagnosis of infection and enable prompt treatment. This is the first report on the diagnosis of scrub typhus in the suburbs of Chennai using molecular methods and reemphasizes the need for increased awareness of rickettsial infections in rural areas.
Acute Cholecystitis in Patients with Scrub Typhus.
Lee, Hyun; Ji, Misuk; Hwang, Jeong-Hwan; Lee, Ja-Yeon; Lee, Ju-Hyung; Chung, Kyung Min; Lee, Chang-Seop
2015-11-01
Acute cholecystitis is a rare complication of scrub typhus. Although a few such cases have been reported in patients with scrub typhus, the clinical course is not well described. Of 12 patients, acute cholecystitis developed in 66.7% (8/12) of patients older than 60 yr. The scrub typhus group with acute cholecystitis had marginal significant longer hospital stay and higher cost than the group without cholecystitis according to propensity score matching. Scrub typhus should be kept in mind as a rare etiology of acute cholecystitis in endemic areas because the typical signs of scrub typhus such as skin rash and eschar can present after the abdominal pain.
Epidemiologic characteristics of scrub typhus on Jeju Island.
Lee, Sung Uk
2017-01-01
Scrub typhus is the most common febrile disease in Korea during the autumn. Jeju Island is the largest island in South Korea and has a distinctive oceanic climate. This study aimed to identify epidemiologic characteristics of scrub typhus on Jeju Island. From January 2011 to December 2016, 446 patients were diagnosed with scrub typhus on Jeju Island. The patients' personal data and the environmental factors that might be related to scrub typhus were investigated and retrospectively analyzed. The median age of the patients was 58-years-old (range, 8 to 91) and 43% of them worked in the agricultural, forestry or livestock industry. Regardless of their job, 87% of the patients had a history of either working outdoors or of other activities before developing scrub typhus. The south and southeast regions of Jeju Island, especially Namwon-eup, showed the highest incidence of scrub typhus. Workers in mandarin orange orchards seemed to be the highest risk group for scrub typhus infection. Scrub typhus on Jeju Island showed unique characteristics. To efficiently prevent scrub typhus, each year individual regional approaches should be developed based on the epidemiologic characteristics of the disease.
Peritonitis in Patients with Scrub Typhus
Lee, Chang-Hun; Lee, Jae-Hoon; Yoon, Ki Jung; Hwang, Jeong-Hwan; Lee, Chang-Seop
2012-01-01
Various complications have been reported in scrub typhus cases including acute respiratory distress syndrome, encephalitis, pneumonia, pericarditis, acute renal failure, and acute hepatic failure. Few studies have reported on the gastrointestinal manifestations of scrub typhus. Typical gastrointestinal manifestations in patients with scrub typhus include abdominal pain, nausea, vomiting, hematemesis, melena, and diarrhea. The two cases presented in this study are the first reported cases of p...
Pool scrubbing and hydrodynamic experiments on jet injection regime
International Nuclear Information System (INIS)
Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez-Jimenez, J.
1995-01-01
Plant analyses have shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination ofboundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanisms acting at the pool entrance. As a consequence, a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei the pool were measured and fitted to a long normal distribution. Particularly, size was found to be quite sensitive to inletgas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major highlights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and
Acute Cholecystitis in Patients with Scrub Typhus
Lee, Hyun; Ji, Misuk; Hwang, Jeong-Hwan; Lee, Ja-Yeon; Lee, Ju-Hyung; Chung, Kyung Min; Lee, Chang-Seop
2015-01-01
Acute cholecystitis is a rare complication of scrub typhus. Although a few such cases have been reported in patients with scrub typhus, the clinical course is not well described. Of 12 patients, acute cholecystitis developed in 66.7% (8/12) of patients older than 60 yr. The scrub typhus group with acute cholecystitis had marginal significant longer hospital stay and higher cost than the group without cholecystitis according to propensity score matching. Scrub typhus should be kept in mind as ...
Endemic Scrub Typhus-like Illness, Chile
2011-09-01
We report a case of scrub typhus in a 54-year-old man who was bitten by several terrestrial leeches during a trip to Chiloé Island in southern...vectors for murine typhus (R. typhi) and fl ea-borne spotted fever (R. felis), mites as vectors of rickettsialpox (R. akari), and scrub typhus ...rickettsial disease have been reported in this country since 1976 (3). Scrub typhus , caused by O. tsutsugamushi, which is usually transmitted by
Molecular detection of Orientia tsutsugamushi from suspected scrub typhus cases
Directory of Open Access Journals (Sweden)
Seethalakshmi Srinivasan
2017-01-01
Full Text Available Context: Scrub typhus is an acute febrile illness caused by Orientia tsutsugamushi. The disease is under-diagnosed in India, because of low index of suspicion and also due to its nonspecific presentation, and lack of confirmatory diagnostic tests. Aims: This study was undertaken to diagnose scrub typhus in patients with undifferentiated fevers by serology and molecular methods. Materials and Methods: A total of 68 blood samples were collected from patients clinically suspected to have scrub typhus. After transportation to the laboratory, the serum was separated from the blood and subjected to rapid card test. The ethylenediaminetetraacetic acid blood samples were subjected to DNA extraction using QIAamp DNA Mini Kit followed by nested polymerase chain reaction (nPCR. Results: 24/68 (35.29% cases showed the presence of antibody against scrub typhus by serology. 6/68 (8.8% patients showed the presence of outer membrane protein antigen gene 56 kDa by nPCR. 5/24 serology positive cases showed the presence of 56 kDa outer membrane protein antigen gene by nPCR. A large number of cases positive by serology were negative by PCR which may indicate a low sensitivity of this test either due to low copy numbers or due to excess host DNA. Conclusion: Delay in treatment may increase disease severity and leads to higher mortality. Thus, molecular methods of diagnosis may aid in the early diagnosis of infection and enable prompt treatment. This is the first report on the diagnosis of scrub typhus in the suburbs of Chennai using molecular methods and reemphasizes the need for increased awareness of rickettsial infections in rural areas.
Predictors of Severity in Pediatric Scrub Typhus.
Narayanasamy, Dinesh Kumar; Arun Babu, Thirunavukkarasu; Vijayadevagaran, Vijayasankar; Kittu, Devi; Ananthakrishnan, Shanthi
2018-01-24
To identify the factors that can predict the severity of scrub typhus in children. This prospective study was conducted at a tertiary care teaching hospital between November 2014 to October 2016. All children scrub typhus were included in the study. These children were followed during the hospital course and their laboratory results, response to treatment and complications were documented. Cases of 'severe scrub typhus' were identified based on criteria from published adult and pediatric studies. Out of 930 children with fever for more than 7d, IgM ELISA for scrub typhus was positive in 230 children. Ninety one (40.6%) cases fulfilled the criteria of 'severe scrub typhus' in children. Out of 45 factors, 27 potential factors were studied. The multivariate analysis identified 5 factors, breathlessness (OR: 6.85, 95%CI: 2.69 to 9.87), altered sensorium (OR: 11.48, 95% CI 3.43 to 10.19), leucocytosis (OR: 3.38, 95% CI 1.12 to 10.16), hypoalbuminemia (OR: 10.78, 95% CI 2.66 to 48.76), and hyponatremia (OR: 10.08, 95% CI 2.11 to 23.42) to be significantly associated with the 'severe scrub typhus' cases. Breathlessness, altered sensorium, leucocytosis, hypoalbuminemia, and hyponatremia predict severity in childhood scrub typhus. Presence of these factors should alert the treating physician regarding the need for intensive monitoring, treatment or referral.
Epidemiologic characteristics of scrub typhus on Jeju Island
Lee, Sung Uk
2017-01-01
OBJECTIVES Scrub typhus is the most common febrile disease in Korea during the autumn. Jeju Island is the largest island in South Korea and has a distinctive oceanic climate. This study aimed to identify epidemiologic characteristics of scrub typhus on Jeju Island. METHODS From January 2011 to December 2016, 446 patients were diagnosed with scrub typhus on Jeju Island. The patients’ personal data and the environmental factors that might be related to scrub typhus were investigated and retrosp...
Macrofungi in the lateritic scrub jungles of southwestern India
Directory of Open Access Journals (Sweden)
A. A. Greeshma
2015-09-01
Full Text Available A pilot study on macrofungi in scrub jungles (with and without fire-impact in lateritic region of southwestern coast of India was carried out. Out of 11 species in 10 genera recovered, six and five species were confined to scrub jungle and fire-impacted scrub jungle, respectively. An ectomycorrhizal Amanita sp. was the most frequent in scrub jungle associated with exotic (Acacia auriculiformis and A. mangium and plantation (Anacardium occidentale trees. Based on traditional knowledge, it is a highly edible and nutritional delicacy in the coastal regions. Astraeus odoratus was another common ectomycorrhizal fungus in native trees Hopea ponga, which was recovered from the fire-impacted scrub jungle and is possibly edible. Edible termite mound mushroom Termitomyces striatus was also common in the fire-impacted scrub jungle. Chlorophyllum molybdites was the most frequent mushroom in the fire-impacted scrub jungle.
Hemorrhagic Transformation of Scrub Typhus Encephalitis: A Rare Entity.
Kim, H-C; Yoon, K-W; Yoo, D-S; Cho, C-S
2015-12-01
Central nervous system (CNS) involvement of scrub typhus infection is well known. Most CNS involvement of scrub typhus infection present as meningitis or encephalitis. We report on a patient suffering from hemorrhagic transformation of intracranial lesions caused by Orientia tsutsugamushi. A 53-year-old female farmer who was infected by scrub typhus was treated with doxycycline and recovered from the systemic illness. However, headache persisted. Brain radiologic studies revealed acute intracranial hemorrhage and enhancing lesion, which implied a CNS involvement. Hemorrhagic transformation of encephalitis by scrub typhus is very rare complication and to our best knowledge, this is the first report of hemorrhagic transformation of scrub typhus encephalitis. Clinician should consider the possibility of hemorrhagic transformation of encephalitis in cases of scrub typhus infection.
Energy Technology Data Exchange (ETDEWEB)
Grieco, E.; Poggio, A. [Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino 10121 (Italy)
2009-09-15
Municipal solid waste incinerators are designed to enhance the electrical efficiency obtained by the plant as much as possible. For this reason strong integration between the flue gas cleaning system and the heat recovery system is required. To provide higher electrical efficiencies acid gas neutralization process has the major importance in flue gas cleaning system. At least four technologies are usually applied for acid gas removal: dry neutralization with Ca(OH){sub 2} or with NaHCO{sub 3}, semi-dry neutralization with milk of lime and wet scrubbing. Nowadays, wet scrubbers are rarely used as a result of the large amount of liquid effluents produced; wet scrubbing technology is often applied as a final treatment after a dry neutralization. Operating conditions of the plant were simulated by using Aspen Plus in order to investigate the influences of four different technologies on the electrical efficiency of the plant. The results of the simulations did not show a great influence of the gas cleaning system on the net electrical efficiency, as the difference between the most advantageous technology (neutralization with NaHCO{sub 3}) and the worst one, is about 1%. (author)
Development of Aerosol Scrubbing Test Loop for Containment Filtered Venting System
International Nuclear Information System (INIS)
Lee, Doo Yong; Jung, Woo Young; Lee, Hyun Chul; Lee, Jong Chan; Kim, Gyu Tae
2016-01-01
The scrubber tank is filled with scrubbing water with the chemical additives. The droplet separator based on a cyclone is installed above the scrubbing water pool to remove the large droplets that may clog a metal fiber filter installed at the upper section of the scrubber tank. The outlet piping is connected from the scrubber tank to the molecular sieve to chemically remove the gaseous iodine. The aerosol as a particle is physically captured in the scrubbing water pool passing through the scrubbing nozzle as well as the metal fiber filter. The gaseous iodine such as molecular iodine as well as organic iodide is chemically removed in the scrubbing water pool and molecular sieve. The thermal-hydraulic as well as scrubbing performance for the CFVS should be verified with the experiments. The experiment can be divided into the filtration component based experiment and whole system based one. In this paper, the aerosol scrubbing test loop developed to test the thermal-hydraulic and aerosol scrubbing performance of the scrubbing nozzle with the scrubbing water pool is introduced. The aerosol scrubbing test loop has been developed as a part of the Korean CFVS project. In this loop, the filtration components such as the scrubbing nozzle submerged in the scrubbing water pool as well as the cyclone as droplet separator can be tested under the CFVS operating conditions. The aerosol scrubbing performance of the filtration components including pool scrubbing behavior can be tested with the aerosol generation and feeding system and aerosol measurement system.
Development of Aerosol Scrubbing Test Loop for Containment Filtered Venting System
Energy Technology Data Exchange (ETDEWEB)
Lee, Doo Yong; Jung, Woo Young; Lee, Hyun Chul; Lee, Jong Chan; Kim, Gyu Tae [FNC Technology, Yongin (Korea, Republic of)
2016-05-15
The scrubber tank is filled with scrubbing water with the chemical additives. The droplet separator based on a cyclone is installed above the scrubbing water pool to remove the large droplets that may clog a metal fiber filter installed at the upper section of the scrubber tank. The outlet piping is connected from the scrubber tank to the molecular sieve to chemically remove the gaseous iodine. The aerosol as a particle is physically captured in the scrubbing water pool passing through the scrubbing nozzle as well as the metal fiber filter. The gaseous iodine such as molecular iodine as well as organic iodide is chemically removed in the scrubbing water pool and molecular sieve. The thermal-hydraulic as well as scrubbing performance for the CFVS should be verified with the experiments. The experiment can be divided into the filtration component based experiment and whole system based one. In this paper, the aerosol scrubbing test loop developed to test the thermal-hydraulic and aerosol scrubbing performance of the scrubbing nozzle with the scrubbing water pool is introduced. The aerosol scrubbing test loop has been developed as a part of the Korean CFVS project. In this loop, the filtration components such as the scrubbing nozzle submerged in the scrubbing water pool as well as the cyclone as droplet separator can be tested under the CFVS operating conditions. The aerosol scrubbing performance of the filtration components including pool scrubbing behavior can be tested with the aerosol generation and feeding system and aerosol measurement system.
A Markov decision process for managing habitat for Florida scrub-jays
Johnson, Fred A.; Breininger, David R.; Duncan, Brean W.; Nichols, James D.; Runge, Michael C.; Williams, B. Ken
2011-01-01
Florida scrub-jays Aphelocoma coerulescens are listed as threatened under the Endangered Species Act due to loss and degradation of scrub habitat. This study concerned the development of an optimal strategy for the restoration and management of scrub habitat at Merritt Island National Wildlife Refuge, which contains one of the few remaining large populations of scrub-jays in Florida. There are documented differences in the reproductive and survival rates of scrubjays among discrete classes of scrub height (Markov models to estimate annual transition probabilities among the four scrub-height classes under three possible management actions: scrub restoration (mechanical cutting followed by burning), a prescribed burn, or no intervention. A strategy prescribing the optimal management action for management units exhibiting different proportions of scrub-height classes was derived using dynamic programming. Scrub restoration was the optimal management action only in units dominated by mixed and tall scrub, and burning tended to be the optimal action for intermediate levels of short scrub. The optimal action was to do nothing when the amount of short scrub was greater than 30%, because short scrub mostly transitions to optimal height scrub (i.e., that state with the highest demographic success of scrub-jays) in the absence of intervention. Monte Carlo simulation of the optimal policy suggested that some form of management would be required every year. We note, however, that estimates of scrub-height transition probabilities were subject to several sources of uncertainty, and so we explored the management implications of alternative sets of transition probabilities. Generally, our analysis demonstrated the difficulty of managing for a species that requires midsuccessional habitat, and suggests that innovative management tools may be needed to help ensure the persistence of scrub-jays at Merritt Island National Wildlife Refuge. The development of a tailored monitoring
Multiple eschars in scrub typhus: a case report.
Koraluru, Munegowda; Nandigam, Manideep; Bairy, Indira; Vidyasagar, Sudha; Varma, Muralidhar
2017-01-01
Eschar in scrub typhus aids in early diagnosis and institution of appropriate therapy; however, the eschar positivity rates vary greatly in endemic regions. Multiple eschars in scrub typhus are a rare presentation. Our patient presented with fever and multiple eschars and was empirically started on doxycycline. Nested polymerase chain reaction from all the four eschars and from EDTA blood were positive for 56-kDa type-specific antigen which is specific for Orientia tsutsugamushi The patient recovered completely after 7 days of antibiotic treatment. He was from an area where scrub typhus was not observed previously. An eschar in an acute febrile patient from the "tsutsugamushi triangle" is a valuable sign in scrub typhus diagnosis. A search for multiple eschars in scrub typhus must be made by clinicians. © The Author(s) 2016.
A Markov decision process for managing habitat for Florida scrub-jays
Johnson, Fred A.; Breininger, David R.; Duncan, Brean W.; Nichols, James D.; Runge, Michael C.; Williams, B. Ken
2011-01-01
Florida scrub-jays Aphelocoma coerulescens are listed as threatened under the Endangered Species Act due to loss and degradation of scrub habitat. This study concerned the development of an optimal strategy for the restoration and management of scrub habitat at Merritt Island National Wildlife Refuge, which contains one of the few remaining large populations of scrub-jays in Florida. There are documented differences in the reproductive and survival rates of scrubjays among discrete classes of scrub height (strategy that would maximize the long-term growth rate of the resident scrub-jay population. We used aerial imagery with multistate Markov models to estimate annual transition probabilities among the four scrub-height classes under three possible management actions: scrub restoration (mechanical cutting followed by burning), a prescribed burn, or no intervention. A strategy prescribing the optimal management action for management units exhibiting different proportions of scrub-height classes was derived using dynamic programming. Scrub restoration was the optimal management action only in units dominated by mixed and tall scrub, and burning tended to be the optimal action for intermediate levels of short scrub. The optimal action was to do nothing when the amount of short scrub was greater than 30%, because short scrub mostly transitions to optimal height scrub (i.e., that state with the highest demographic success of scrub-jays) in the absence of intervention. Monte Carlo simulation of the optimal policy suggested that some form of management would be required every year. We note, however, that estimates of scrub-height transition probabilities were subject to several sources of uncertainty, and so we explored the management implications of alternative sets of transition probabilities. Generally, our analysis demonstrated the difficulty of managing for a species that requires midsuccessional habitat, and suggests that innovative management tools may be needed to
Scrub typhus: audit of an outbreak.
Krishna, Mani Ram; Vasuki, B; Nagaraju, K
2015-06-01
To document the epidemiological, clinical and laboratory profile of all children with scrub typhus at a tertiary care centre in Chennai between September 2010 and June 2011. The case records of all children admitted and diagnosed with scrub typhus between September 2010 and June 2011 were analysed to look for salient clinical and laboratory parameters. During the study period, 52 children were admitted with scrub typhus in the authors' hospital. The presenting complaints included fever in all cases. Other symptoms included swelling of legs (50 %) and vomiting (45 %). 13 % presented with CNS symptoms. The commonest physical findings included eschar (67 %), hepatomegaly (94 %), splenomegaly (73 %) and third spacing (67 %). Salient lab parameters included packed cell volume (PCV) scrub typhus in a tertiary care centre is reported. Eschar and hepatosplenomegaly with a high CRP value is helpful in diagnosis. All patients responded well to the treatment.
International Nuclear Information System (INIS)
Kim, Kyu Sik; Kang, Sung Soo; Jin, Kong Yong; Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Chung, Gyung Ho; Lee, Sang Yong; Sohn, Myung Hee; Choi, Ki Chul
1997-01-01
To evaluate high-resolution CT (HRCT) findings of scrub typhus. We retrospectively reviewed the HRCT scans of 26 serologically confirmed scrub typhus patients. One underwent follow-up HRCT scanning. Twenty-three(88.5%) of the 26 patients showed abnormal findings. All 23 had lung parenchymal lesions; a small amount of pleural effusion was seen in 11 patients, and lymphadenopathy in six. The predominant parenchymal lesion was thickening of interlobular septae and the axial and intralobular interstitium (n=16). Most lesions were located in both lower lung zones. Other findings were ground-glass attenuation (n=11) and focal parenchymal consolidation (n=8). In one patient, parenchymal lesions were resolved on follow-up HRCT scanning. HRCT findings of interstitial thickening, abnormally increased parenchymal attenuation, pleural effusion and lymphadenopathy with typical clinical symptoms were diagnostic of scrub typhus
Energy Technology Data Exchange (ETDEWEB)
Kim, Kyu Sik; Kang, Sung Soo; Jin, Kong Yong; Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Chung, Gyung Ho; Lee, Sang Yong; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National Univ. Medical School, Chonju (Korea, Republic of)
1997-06-01
To evaluate high-resolution CT (HRCT) findings of scrub typhus. We retrospectively reviewed the HRCT scans of 26 serologically confirmed scrub typhus patients. One underwent follow-up HRCT scanning. Twenty-three(88.5%) of the 26 patients showed abnormal findings. All 23 had lung parenchymal lesions; a small amount of pleural effusion was seen in 11 patients, and lymphadenopathy in six. The predominant parenchymal lesion was thickening of interlobular septae and the axial and intralobular interstitium (n=16). Most lesions were located in both lower lung zones. Other findings were ground-glass attenuation (n=11) and focal parenchymal consolidation (n=8). In one patient, parenchymal lesions were resolved on follow-up HRCT scanning. HRCT findings of interstitial thickening, abnormally increased parenchymal attenuation, pleural effusion and lymphadenopathy with typical clinical symptoms were diagnostic of scrub typhus.
A case of scrub typhus requiring maintenance hemodialysis
Directory of Open Access Journals (Sweden)
Dae-Yeon Kim
2013-12-01
Full Text Available Renal failure caused by scrub typhus is known to be reversible. In most cases, renal function is almost fully restored after appropriate antibiotic treatment. A 71-year-old man was diagnosed with scrub typhus complicated by renal failure. A renal biopsy revealed histopathologic findings consistent with acute tubulointerstitial nephritis. Renal function did not improve 18 months after discharge and the patient required continuous hemodialysis. Although severe renal failure requiring dialysis is a rare complication of scrub typhus, we describe a case of scrub typhus requiring maintenance hemodialysis. To the best of our knowledge, this is the first such report.
Extracorporeal Membrane Oxygenation for Complicated Scrub Typhus
Directory of Open Access Journals (Sweden)
Eun Sun Kim
Full Text Available Scrub typhus is a mite-borne infectious disease caused by Orientia tsutsugamushi . Although early diagnosis and appropriate antibiotic therapy improve the prognosis for the majority of patients, life-threatening complications are not uncommon. Here, we present a case of successful veno-veno-type extracorporeal membrane oxygenation for scrub typhus-induced complications, including acute respiratory distress syndrome, myocarditis and multi-organ dysfunction. To our knowledge, this is the first case report of successful extracorporeal membrane oxygenation in complicated scrub typhus in Korea.
International Nuclear Information System (INIS)
Lopez-Jimenez, J.; Herranz, J.; Escudero, M.J.; Espigares, M.M.; Peyres, V.; Polo, J.; Kortz, Ch.; Koch, M.K.; Brockmeier, U.; Unger, H.; Dutton, L.M.C.; Smedley, Ch.; Trow, W.; Jones, A.V.; Bonanni, E.; Calvo, M.; Alonso, A.
1996-12-01
The Source Term Project in the Third Frame Work Programme of the European Union Was conducted under and important joined effort on pool scrubbing research. CIEMAT was the Task Manager of the project and several other organizations participated in it: JRC-Ispra, NNC Limited, RUB-NES and UPM. The project was divided into several tasks. A peer review of the models in the pool scrubbing codes SPARC90 and BUSCA-AUG92 was made, considering the different aspects in the hydrodynamic phenomenology, particle retention and fission product vapor abortions. Several dominant risk accident sequences were analyzed with MAAP, SPARC90 and BUSCA-AUG92 codes, and the predictions were compared. A churn-turbulent model was developed for the hydrodynamic behaviour of the pool. Finally, an experimental programme in the PECA facility of CIEMAT was conducted in order to study the decontamination factor under jet injection regime, and the experimental observations were compared with the SPARC and BUSCA codes. (Author)
Seroprevalence of Scrub Typhus Infection in Arunachal Pradesh, India.
Jakharia, Aniruddha; Borkakoty, Biswajyoti; Biswas, Dipankar; Yadav, Kaushal; Mahanta, Jagadish
2016-10-01
Scrub typhus is a major reason for febrile illness, caused by a bacterium Orientia tsutsugamushi, a rickettsial pathogen. Few outbreaks of scrub typhus have been reported from Arunachal Pradesh in recent past. However, there is lack of seroprevalence data from the region. In this regard, this study was undertaken using archival serum sample available from seven districts of Arunachal Pradesh. This serological study was conducted in Regional Medical Research Center for NE Region, Dibrugarh. Reactivity to IgG class of antibodies against scrub typhus was done using Scrub typhus detect IgG ELISA kit as per manufacturer's protocol. Seroprevalence of scrub typhus in seven districts of Arunachal Pradesh was found to be 40% (120/300). The age-specific scrub typhus seroprevalence rose steadily from 5.6% in children scrub typhus infection should be considered in differential diagnosis of any acute febrile illness in this part of the country. In view of the high prevalence, empirical therapy of doxycycline/azithromycin may be done in cases of undiagnosed fever. Active surveillance has to be done to understand exact magnitude, epidemiological aspects, and distribution of vector and disease of this reemerging neglected tropical disease.
Directory of Open Access Journals (Sweden)
Alok Bhatt
2014-01-01
Full Text Available Scrub typhus is a rickettsial infection prevalent in most parts of India. Acute pancreatitis with pseudocyst formation is a rare complication of this condition. This paper reports acute renal failure, pancreatitis and pseudocyst formation in a 48-year-old female with scrub typhus. Ultrasonography of the abdomen revealed a bulky pancreas with fluid seen along the body of the pancreas in the lesser sac. The infection was successfully treated with doxycycline and supportive treatment. Pancreatitis was managed conservatively. This case report highlights the importance of identifying and managing uncommon complications of a common tropical disease for optimum outcome.
DEFF Research Database (Denmark)
Fehrmann, Rasmus
2014-01-01
and dry scrubbing for sulfur oxides (SO2) and catalytic removal of nitrogen oxides (NOx). There is however, a desire of increasing the energy produced in electrical power plants by firing CO2-neutral biomass/waste or biomass/waste in combination with fossil fuels. Thus, the EU reached agreement in March......-time. But the problems may also be attacked by new materials like supported ionic liquid phase (SILP) gas absorbers where the pollutants may be selectively absorbed, desorbed and finally converted to useful mineral acids of commercial grade – really a green waste-to-value approach that we persue instead...
Scrub typhus en Scrub itch, in het bijzonder in Nieuw Guinea
Hammen, van der L.
1956-01-01
INHOUD Pag. I. Inleiding.................. 1 II. Historisch overzicht............... 3 III. Epidemiologie en oecologie............. 13 IV. Klinische waarnemingen, pathologie, diagnose en behandeling .... 24 V. Aetiologie.................. 27 VI. Scrub itch.................. 28 VII. Preventieve
Energy Technology Data Exchange (ETDEWEB)
Na, Young Su; Ha, Kwang Soon; Kim, Sungil; Cho, Song-Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2015-10-15
When the pressure in the containment building approaches a setting value, the FCVS(Filtered Containment Venting System) operates. The amount of steam and gas mixtures generated during a severe accident can be released into the FCVS. Non-condensable gases and fine aerosols can pass a scrubbing solution and the filters in the FCVS vessel. The decontaminated gases are finally discharged from the FCVS to the outside environment. Previous study observed that a scrubbing solution in the FCVS vessel was constantly evaporating owing to high-temperature steam released continuously from the containment building. A scrubbing solution in the FCVS vessel was completely evaporated at about 31 hours after the FCVS operation. Pool evaporation in the FCVS vessel can negatively affect the decontamination feature of the FCVS because it reduces the scrubbing depth for fission products in an aerosol form. This study carefully evaluated the decontamination factor of metal iodide aerosols especially cesium iodide (CsI), on a scrubbing solution in the FCVS. This paper summarizes the calculated results on the decontamination factor of CsI in the FCVS vessel, which was presented at the international OECD-NEA/NUGENIA-SARNET workshop. This study estimated the decontamination factor of CsI on a scrubbing solution in the FCVS. The MELCOR computer code simulated that an SBO occurred in the OPR 1000. The FCVS consists of a cylindrical vessel with a 3 m diameter and 6.5 m height, and it includes a scrubbing solution of 21 tons. Accumulated mass of CsI aerosol was calculated in a scrubbing solution and the atmosphere in the FCVS vessel and the outside environment. In the early FCVS operation, the decontamination factor of CsI aerosol rapidly increased owing to steam condensation in a scrubbing solution. When the temperature of a pool approached its saturation temperature, the decontamination factor of CsI aerosol started to decrease.
Scrub Typhus Outbreak in a Remote Primary School, Bhutan, 2014.
Tshokey, Tshokey; Graves, Stephen; Tshering, Dorji; Phuntsho, Kelzang; Tshering, Karchung; Stenos, John
2017-08-01
Scrub typhus in Bhutan was first reported in 2009. We investigated an outbreak of scrub typhus in a remote primary school during August-October 2014. Delay in recognition and treatment resulted in 2 deaths from meningoencephalitis. Scrub typhus warrants urgent public health interventions in Bhutan.
Scrub Typhus Outbreak in a Remote Primary School, Bhutan, 2014
Tshokey, Tshokey; Graves, Stephen; Tshering, Dorji; Phuntsho, Kelzang; Tshering, Karchung; Stenos, John
2017-01-01
Scrub typhus in Bhutan was first reported in 2009. We investigated an outbreak of scrub typhus in a remote primary school during August?October 2014. Delay in recognition and treatment resulted in 2 deaths from meningoencephalitis. Scrub typhus warrants urgent public health interventions in Bhutan.
Spatiotemporal Dynamics of Scrub Typhus Transmission in Mainland China, 2006-2014.
Wu, Yi-Cheng; Qian, Quan; Soares Magalhaes, Ricardo J; Han, Zhi-Hai; Hu, Wen-Biao; Haque, Ubydul; Weppelmann, Thomas A; Wang, Yong; Liu, Yun-Xi; Li, Xin-Lou; Sun, Hai-Long; Sun, Yan-Song; Clements, Archie C A; Li, Shen-Long; Zhang, Wen-Yi
2016-08-01
Scrub typhus is endemic in the Asia-Pacific region including China, and the number of reported cases has increased dramatically in the past decade. However, the spatial-temporal dynamics and the potential risk factors in transmission of scrub typhus in mainland China have yet to be characterized. This study aims to explore the spatiotemporal dynamics of reported scrub typhus cases in mainland China between January 2006 and December 2014, to detect the location of high risk spatiotemporal clusters of scrub typhus cases, and identify the potential risk factors affecting the re-emergence of the disease. Monthly cases of scrub typhus reported at the county level between 2006 and 2014 were obtained from the Chinese Center for Diseases Control and Prevention. Time-series analyses, spatiotemporal cluster analyses, and spatial scan statistics were used to explore the characteristics of the scrub typhus incidence. To explore the association between scrub typhus incidence and environmental variables panel Poisson regression analysis was conducted. During the time period between 2006 and 2014 a total of 54,558 scrub typhus cases were reported in mainland China, which grew exponentially. The majority of cases were reported each year between July and November, with peak incidence during October every year. The spatiotemporal dynamics of scrub typhus varied over the study period with high-risk clusters identified in southwest, southern, and middle-eastern part of China. Scrub typhus incidence was positively correlated with the percentage of shrub and meteorological variables including temperature and precipitation. The results of this study demonstrate areas in China that could be targeted with public health interventions to mitigate the growing threat of scrub typhus in the country.
Clinical proteomic analysis of scrub typhus infection.
Park, Edmond Changkyun; Lee, Sang-Yeop; Yun, Sung Ho; Choi, Chi-Won; Lee, Hayoung; Song, Hyun Seok; Jun, Sangmi; Kim, Gun-Hwa; Lee, Chang-Seop; Kim, Seung Il
2018-01-01
Scrub typhus is an acute and febrile infectious disease caused by the Gram-negative α-proteobacterium Orientia tsutsugamushi from the family Rickettsiaceae that is widely distributed in Northern, Southern and Eastern Asia. In the present study, we analysed the serum proteome of scrub typhus patients to investigate specific clinical protein patterns in an attempt to explain pathophysiology and discover potential biomarkers of infection. Serum samples were collected from three patients (before and after treatment with antibiotics) and three healthy subjects. One-dimensional sodium dodecyl sulphate-polyacrylamide gel electrophoresis followed by liquid chromatography-tandem mass spectrometry was performed to identify differentially abundant proteins using quantitative proteomic approaches. Bioinformatic analysis was then performed using Ingenuity Pathway Analysis. Proteomic analysis identified 236 serum proteins, of which 32 were differentially expressed in normal subjects, naive scrub typhus patients and patients treated with antibiotics. Comparative bioinformatic analysis of the identified proteins revealed up-regulation of proteins involved in immune responses, especially complement system, following infection with O. tsutsugamushi , and normal expression was largely rescued by antibiotic treatment. This is the first proteomic study of clinical serum samples from scrub typhus patients. Proteomic analysis identified changes in protein expression upon infection with O. tsutsugamushi and following antibiotic treatment. Our results provide valuable information for further investigation of scrub typhus therapy and diagnosis.
Estimating the burden of scrub typhus: A systematic review.
Directory of Open Access Journals (Sweden)
Ana Bonell
2017-09-01
Full Text Available Scrub typhus is a vector-borne zoonotic disease that can be life-threatening. There are no licensed vaccines, or vector control efforts in place. Despite increasing awareness in endemic regions, the public health burden and global distribution of scrub typhus remains poorly known.We systematically reviewed all literature from public health records, fever studies and reports available on the Ovid MEDLINE, Embase Classic + Embase and EconLit databases, to estimate the burden of scrub typhus since the year 2000.In prospective fever studies from Asia, scrub typhus is a leading cause of treatable non-malarial febrile illness. Sero-epidemiological data also suggest that Orientia tsutsugamushi infection is common across Asia, with seroprevalence ranging from 9.3%-27.9% (median 22.2% IQR 18.6-25.7. A substantial apparent rise in minimum disease incidence (median 4.6/100,000/10 years, highest in China with 11.2/100,000/10 years was reported through passive national surveillance systems in South Korea, Japan, China, and Thailand. Case fatality risks from areas of reduced drug-susceptibility are reported at 12.2% and 13.6% for South India and northern Thailand, respectively. Mortality reports vary widely around a median mortality of 6.0% for untreated and 1.4% for treated scrub typhus. Limited evidence suggests high mortality in complicated scrub typhus with CNS involvement (13.6% mortality, multi-organ dysfunction (24.1% and high pregnancy miscarriage rates with poor neonatal outcomes.Scrub typhus appears to be a truly neglected tropical disease mainly affecting rural populations, but increasingly also metropolitan areas. Rising minimum incidence rates have been reported over the past 8-10 years from countries with an established surveillance system. A wider distribution of scrub typhus beyond Asia is likely, based on reports from South America and Africa. Unfortunately, the quality and quantity of the available data on scrub typhus epidemiology is
Estimating the burden of scrub typhus: A systematic review.
Bonell, Ana; Lubell, Yoel; Newton, Paul N; Crump, John A; Paris, Daniel H
2017-09-01
Scrub typhus is a vector-borne zoonotic disease that can be life-threatening. There are no licensed vaccines, or vector control efforts in place. Despite increasing awareness in endemic regions, the public health burden and global distribution of scrub typhus remains poorly known. We systematically reviewed all literature from public health records, fever studies and reports available on the Ovid MEDLINE, Embase Classic + Embase and EconLit databases, to estimate the burden of scrub typhus since the year 2000. In prospective fever studies from Asia, scrub typhus is a leading cause of treatable non-malarial febrile illness. Sero-epidemiological data also suggest that Orientia tsutsugamushi infection is common across Asia, with seroprevalence ranging from 9.3%-27.9% (median 22.2% IQR 18.6-25.7). A substantial apparent rise in minimum disease incidence (median 4.6/100,000/10 years, highest in China with 11.2/100,000/10 years) was reported through passive national surveillance systems in South Korea, Japan, China, and Thailand. Case fatality risks from areas of reduced drug-susceptibility are reported at 12.2% and 13.6% for South India and northern Thailand, respectively. Mortality reports vary widely around a median mortality of 6.0% for untreated and 1.4% for treated scrub typhus. Limited evidence suggests high mortality in complicated scrub typhus with CNS involvement (13.6% mortality), multi-organ dysfunction (24.1%) and high pregnancy miscarriage rates with poor neonatal outcomes. Scrub typhus appears to be a truly neglected tropical disease mainly affecting rural populations, but increasingly also metropolitan areas. Rising minimum incidence rates have been reported over the past 8-10 years from countries with an established surveillance system. A wider distribution of scrub typhus beyond Asia is likely, based on reports from South America and Africa. Unfortunately, the quality and quantity of the available data on scrub typhus epidemiology is currently too
Directory of Open Access Journals (Sweden)
Shubhanker Mitra
2017-01-01
Full Text Available Background: Dengue and scrub typhus share similar clinical and epidemiological features, and are difficult to differentiate at initial presentation. Many places are endemic to both these infections where they comprise the majority of acute undifferentiated febrile illnesses. Materials and Methods: We aimed to develop a score that can differentiate scrub typhus from dengue. In this cross-sectional study, 188 cases of scrub typhus and 201 cases of dengue infection who presented to the emergency department or medicine outpatient clinic from September 2012 to April 2013 were included. Univariate followed by multivariate logistic regression analysis was performed to identify clinical features and laboratory results that were significantly different between the two groups. Each variable was assigned scores based on the strength of association and receiver operating characteristics area under the curve (ROC-AUC was generated and compared. Six scoring models were explored to ascertain the model with the best fit. Results: Model 2 was developed using the following six variables: oxygen saturation (>90%, ≤90%, total white blood cell count (7000 cells/cumm, hemoglobin (≤14 and >14 g/dL, total bilirubin (200 and ≥200 IU/dL, and altered sensorium (present or absent. Each variable was assigned scores based on its strength of association. The AUC-ROC curve (95% confidence interval for model 2 was 0.84 (0.79–0.89. At the cut off score of 13, the sensitivity and specificity were 85% and 77% respectively, with a higher score favoring dengue. Conclusion: In areas of high burden of ST and dengue, model 2 (the “clinical score to differentiate scrub typhus and dengue fever” is a simple and rapid clinical scoring system that may be used to differentiate scrub typhus and dengue at initial presentation.
Mitra, Shubhanker; Gautam, Ira; Jambugulam, Mohan; Abhilash, Kundavaram Paul Prabhakar; Jayaseeelan, Vishalakshi
2017-01-01
Dengue and scrub typhus share similar clinical and epidemiological features, and are difficult to differentiate at initial presentation. Many places are endemic to both these infections where they comprise the majority of acute undifferentiated febrile illnesses. We aimed to develop a score that can differentiate scrub typhus from dengue. In this cross-sectional study, 188 cases of scrub typhus and 201 cases of dengue infection who presented to the emergency department or medicine outpatient clinic from September 2012 to April 2013 were included. Univariate followed by multivariate logistic regression analysis was performed to identify clinical features and laboratory results that were significantly different between the two groups. Each variable was assigned scores based on the strength of association and receiver operating characteristics area under the curve (ROC-AUC) was generated and compared. Six scoring models were explored to ascertain the model with the best fit. Model 2 was developed using the following six variables: oxygen saturation (>90%, ≤90%), total white blood cell count (7000 cells/cumm), hemoglobin (≤14 and >14 g/dL), total bilirubin (200 and ≥200 IU/dL), and altered sensorium (present or absent). Each variable was assigned scores based on its strength of association. The AUC-ROC curve (95% confidence interval) for model 2 was 0.84 (0.79-0.89). At the cut off score of 13, the sensitivity and specificity were 85% and 77% respectively, with a higher score favoring dengue. In areas of high burden of ST and dengue, model 2 (the "clinical score to differentiate scrub typhus and dengue fever") is a simple and rapid clinical scoring system that may be used to differentiate scrub typhus and dengue at initial presentation.
Acute pancreatitis due to scrub typhus
Directory of Open Access Journals (Sweden)
Atif Shaikh Iqbal Ahmed
2014-01-01
Full Text Available Scrub typhus is endemic in large parts of India and can cause multi-organ failure and death. Acute pancreatitis as a complication is very rare and is potentially fatal. This case series describes seven adult patients who presented with an acute febrile illness and were diagnosed to have scrub typhus with acute pancreatitis. The mean age of the seven patients with acute pancreatitis was 49.4 years, and mean duration of fever prior to presentation was 7.7 days. All seven patients had abdominal pain, and three had a pathognomonic eschar. The mean serum lipase level was 1,509 U/L (normal value: <190 U/L and the mean serum amylase level was 434 U/L (normal value: <200 U/L. Six patients had evidence of multi-organ dysfunction. Hematological and respiratory system dysfunction was seen in five patients, hepatic and renal dysfunction in four, and central nervous system dysfunction in three patients. Three patients who had ≥4 organs involved, died (mortality rate: 42.8%. Our case series shows that pancreatitis in scrub typhus is an extremely rare complication and when present, is associated with increased mortality (42.8%. Physicians may be familiar with the various complications of scrub typhus but less so with acute pancreatitis and hence may be underdiagnosed.
Radford, Eleanor J; Fotis, Theo
2018-01-01
Operating theatre scrub nurses (OTSNs) are not required to have undertaken a secondary or specialist post-registration theatre qualification to work in the operating theatre (OT) setting in the UK. From the systematic review there is only very limited literature or research in how technical scrub skills are acquired. This study explores the lived experiences of OTSNs learning technical scrub skills. The study employed the qualitative methodology of interpretative phenomenological analysis. Data was collected from six participating OTSNs using semi-structured interviews. Four superordinate themes emerged: How technical scrub skills are established, Gatekeepers, How the learner feels whilst learning and, Reflections of the experienced scrub nurse. The study found that the experiences of OTSNs learning technical scrub skills are varied and a variety of teaching and learning methods are utilised. These experiences were influenced by the team, mentor and surgeon within the OT environment. Lived experiences were also influenced by organisational structure and service pressures within the NHS.
Assessment of ASTEC-CPA pool scrubbing models against POSEIDON-II and SGTR-ARTIST data
International Nuclear Information System (INIS)
Herranz, Luis E.; Fontanet, Joan
2009-01-01
Aerosol scrubbing in pools mitigates the potential source term in key severe accident scenarios in PWRs and BWRs. Even though models were extensively validated in the past, a thorough and systematic validation under key challenging conditions is missing. Some of those conditions are high injection velocity, high pool temperature and/or presence of submerged structures. In particular, in-code models have been neither updated nor validated based on the most recent experimental data. The POSEIDON-II and the SGTR-ARTIST projects produced sets of data under conditions of utmost interest for pool scrubbing validation: high temperature and submerged structures. This paper investigates the response of models encapsulated in the CPA module of the ASTEC code in the simulation of those experimental set-ups. The influence of key pool scrubbing variables like steam fraction, water depth, gas flow-rate and particle size has been analyzed. Additionally, comparisons to stand-alone code (i.e., SPARC90) responses have also been obtained, so that prediction-to-data deviations can be discussed and attributed to either model grounds and/or model implementation in integral accident codes. This work has demonstrated that ASTEC-CPA limitations to capture fundamental trends of aerosol pool scrubbing are substantial (although the SGTR scenarios should not be properly considered within the CPA scope) and they stem from both original models (i.e., SPARC90) and model implementation. This work has been carried out within the European SARNET project of the VI Framework Program of EURATOM. (author)
Gas separation by composite solvent-swollen membranes
Matson, Stephen L.; Lee, Eric K. L.; Friesen, Dwayne T.; Kelly, Donald J.
1989-01-01
There is disclosed a composite immobulized liquid membrane of a solvent-swollen polymer and a microporous organic or inorganic support, the solvent being at least one highly polar solvent containing at least one nitrogen, oxygen, phosphorous or sulfur atom, and having a boiling point of at least 100.degree. C. and a specified solubility parameter. The solvent or solvent mixture is homogeneously distributed through the solvent-swollen polymer from 20% to 95% by weight. The membrane is suitable for acid gas scrubbing and oxygen/nitrogen separation.
Gas separation by composite solvent-swollen membranes
Matson, S.L.; Lee, E.K.L.; Friesen, D.T.; Kelly, D.J.
1989-04-25
There is disclosed a composite immobilized liquid membrane of a solvent-swollen polymer and a microporous organic or inorganic support, the solvent being at least one highly polar solvent containing at least one nitrogen, oxygen, phosphorus or sulfur atom, and having a boiling point of at least 100 C and a specified solubility parameter. The solvent or solvent mixture is homogeneously distributed through the solvent-swollen polymer from 20% to 95% by weight. The membrane is suitable for acid gas scrubbing and oxygen/nitrogen separation. 3 figs.
Scrub Typhus Incidence Modeling with Meteorological Factors in South Korea.
Kwak, Jaewon; Kim, Soojun; Kim, Gilho; Singh, Vijay P; Hong, Seungjin; Kim, Hung Soo
2015-06-29
Since its recurrence in 1986, scrub typhus has been occurring annually and it is considered as one of the most prevalent diseases in Korea. Scrub typhus is a 3rd grade nationally notifiable disease that has greatly increased in Korea since 2000. The objective of this study is to construct a disease incidence model for prediction and quantification of the incidences of scrub typhus. Using data from 2001 to 2010, the incidence Artificial Neural Network (ANN) model, which considers the time-lag between scrub typhus and minimum temperature, precipitation and average wind speed based on the Granger causality and spectral analysis, is constructed and tested for 2011 to 2012. Results show reliable simulation of scrub typhus incidences with selected predictors, and indicate that the seasonality in meteorological data should be considered.
Scrub Typhus Incidence Modeling with Meteorological Factors in South Korea
Directory of Open Access Journals (Sweden)
Jaewon Kwak
2015-06-01
Full Text Available Since its recurrence in 1986, scrub typhus has been occurring annually and it is considered as one of the most prevalent diseases in Korea. Scrub typhus is a 3rd grade nationally notifiable disease that has greatly increased in Korea since 2000. The objective of this study is to construct a disease incidence model for prediction and quantification of the incidences of scrub typhus. Using data from 2001 to 2010, the incidence Artificial Neural Network (ANN model, which considers the time-lag between scrub typhus and minimum temperature, precipitation and average wind speed based on the Granger causality and spectral analysis, is constructed and tested for 2011 to 2012. Results show reliable simulation of scrub typhus incidences with selected predictors, and indicate that the seasonality in meteorological data should be considered.
Associated factors and clinical implications of serum aminotransferase elevation in scrub typhus.
Su, Tung-Hung; Liu, Chun-Jen; Shu, Pei-Yun; Fu, Yang-Hsien; Chang, Chi-Hsien; Jao, Ping; Kao, Jia-Horng
2016-12-01
Timely diagnosis and prompt treatment can reduce the complications of scrub typhus. It is thus important to find easy laboratory tests to help in the diagnosis, especially in patients without eschar at initial presentation. Because serum aminotransferase elevation is common in scrub typhus, its associated factors and clinical implications need further investigations. We conducted a retrospective study in Kinmen, Taiwan, to collect clinically suspected scrub typhus patients notified to Taiwan Centers for Disease Control for confirmation during 2005-2010. Scrub typhus was diagnosed and Orientia tsutsugamushi was genotyped by serological or molecular assays. The laboratory data and clinical information were recorded for analysis. Overall, 344 suspected scrub typhus patients were reported to Taiwan Centers for Disease Control and 288 of them were certified scrub typhus. Scrub typhus patients had significantly more thrombocytopenia, serum aminotransferase elevation (76% vs. 54%, p = 0.001), higher frequency of fever, eschar, and lymphadenopathy, compared with nontyphus patients. Hepatic dysfunction in scrub typhus was associated with older age, longer fever duration, and absence of lymphadenopathy, but seemed to be unrelated to the rickettsial genotypes. Multivariate analysis showed that serum aminotransferase elevation (odds ratio: 3.75; p = 0.003; 95% confidence interval: 1.56-9.01) independently predicted scrub typhus. Furthermore, in suspected scrub typhus patients without eschar, 92% of true typhus patients had serum aminotransferase elevation compared with the nontyphus ones (odds ratio: 6.47; p = 0.028, 95% confidence interval: 1.23-34.11). Hepatic dysfunction in scrub typhus patients is associated with older age, longer fever duration, and absence of lymphadenopathy. Serum aminotransferase elevation can aid in the diagnosis of scrub typhus, especially in suspected patients without eschar. Copyright © 2014. Published by Elsevier B.V.
Climate variability, animal reservoir and transmission of scrub typhus in Southern China.
Wei, Yuehong; Huang, Yong; Li, Xiaoning; Ma, Yu; Tao, Xia; Wu, Xinwei; Yang, Zhicong
2017-03-01
We aimed to evaluate the relationships between climate variability, animal reservoirs and scrub typhus incidence in Southern China. We obtained data on scrub typhus cases in Guangzhou every month from 2006 to 2014 from the Chinese communicable disease network. Time-series Poisson regression models and distributed lag nonlinear models (DLNM) were used to evaluate the relationship between risk factors and scrub typhus. Wavelet analysis found the incidence of scrub typhus cycled with a period of approximately 8-12 months and long-term trends with a period of approximately 24-36 months. The DLNM model shows that relative humidity, rainfall, DTR, MEI and rodent density were associated with the incidence of scrub typhus. Our findings suggest that the incidence scrub typhus has two main temporal cycles. Determining the reason for this trend and how it can be used for disease control and prevention requires additional research. The transmission of scrub typhus is highly dependent on climate factors and rodent density, both of which should be considered in prevention and control strategies for scrub typhus.
Rapid Increase in Scrub Typhus Incidence in Mainland China, 2006-2014.
Wu, Yi-Cheng; Qian, Quan; Magalhaes, Ricardo J Soares; Han, Zhi-Hai; Haque, Ubydul; Weppelmann, Thomas A; Hu, Wen-Biao; Liu, Yun-Xi; Sun, Yan-Song; Zhang, Wen-Yi; Li, Shen-Long
2016-03-01
Scrub typhus is a vector-borne disease, which has recently reemerged in China. In this study, we describe the distribution and incidence of scrub typhus cases in China from 2006 to 2014 and quantify differences in scrub typhus cases with respect to sex, age, and occupation. The results of our study indicate that the annual incidence of scrub typhus has increased during the study period. The number of cases peaked in 2014, which was 12.8 times greater than the number of cases reported in 2006. Most (77.97%) of the cases were reported in five provinces (Guangdong, Yunnan, Anhui, Fujian, and Shandong). Our study also demonstrates that the incidence rate of scrub typhus was significantly higher in females compared to males (P scrub typhus incidence, but also document an expansion in the geographic distribution throughout the country. © The American Society of Tropical Medicine and Hygiene.
Tsai, Jui-Chen; Lin, Yen-Kuang; Huang, Yen-Jung; Loh, El-Wui; Wen, Hsiao-Yun; Wang, Chia-Hui; Tsai, Yin-Tai; Hsieh, Wen-Shyang; Tam, Ka-Wai
2017-04-01
OBJECTIVE Effective perioperative hand antisepsis is crucial for the safety of patients and medical staff in surgical rooms. The antimicrobial effectiveness of different antiseptic methods, including conventional hand scrubs and waterless hand rubs, has not been well evaluated. DESIGN, SETTING, AND PARTICIPANTS A randomized controlled trial was conducted to investigate the effectiveness of the 3 antiseptic methods among surgical staff of Taipei Medical University-Shuang Ho Hospital. For each method used, a group of 80 participants was enrolled. INTERVENTION Surgical hand cleansing with conventional 10% povidone-iodine scrub, conventional 4% chlorhexidine scrub, or waterless hand rub (1% chlorhexidine gluconate and 61% ethyl alcohol). RESULTS Colony-forming unit (CFU) counts were collected using the hand imprinting method before and after disinfection and after surgery. After surgical hand disinfection, the mean CFU counts of the conventional chlorhexidine (0.5±0.2, Pantiseptic method (P=.0036), but not other variables, predicted the mean CFU count. CONCLUSIONS Conventional chlorhexidine scrub and waterless hand rub were superior to a conventional povidone-iodine product in bacterial inhibition. We recommend using conventional chlorhexidine scrub as a standard method for perioperative hand antisepsis. Waterless hand rub may be used if the higher cost is affordable. Infect Control Hosp Epidemiol 2017;38:417-422.
Concept of off-gas purification in reprocessing plants
International Nuclear Information System (INIS)
Henrich, E.; von Ammon, R.
1986-01-01
Concepts and individual processes for the off-gas purification in reprocessing plants are described which are suited to achieve a better retention of the gaseous and volatile radionuclides 129 I, 85 Kr, 14 C, and tritium. Improved and new process steps have been developed to the cold pilot plant scale. Essential individual process steps are an efficient iodine desorption from the dissolver solution, improved and new off-gas scrubs with nitric acid, a cryogenic as well as a selective absorption process for rare gas recovery plus the required prepurification steps and a process for the continuous and pressure-free fixation and storage of krypton in a metal matrix. Individual facilities have been selected and combined to investigate integrated dissolver off-gas systems. Advanced concepts based on a process using low flows and loads of all off-gas streams including the cell ventilation off-gas are briefly discussed
Scrub Typhus: An Emerging Neglected Tropical Disease in Nepal.
Upadhyaya, B P; Shakya, G; Adhikari, S; Rijal, N; Acharya, J; Maharjan, L; Marasini, B R
2016-05-01
Scrub typhus is a neglected tropical disease and is under reported from Nepal. The objective of this study was to investigate the sero-epidemiology of scrub typhus in patients suffering from acute febrile illness. A total of 434 specimens collected from July to November 2015 at National Public Health Laboratory (NPHL) were investigated for detection of immunoglobulin M (IgM) antibody to Orientiatsutsugamushi.The Scrub Typhus Detect TM kit (InBios, USA) was used to detect the antibodies to O.tsutsugamushi in human serum. Randomly selected 10% positive specimens were used for confirmation by dot- enzyme-linked immunosorbent assay and indirect immunofluorescence assay. Of the total, 175 (40.3%) were positive for IgM antibodies to O. tsutsugamushi. Positive results of scrub typhus were highest among female in 11-20 year followed by males in 41-50 years age group. The IgM antibodies to O. tsutusugamushi were positive in specimens of various geographical regions including 30 districts of Nepal. Positive cases were found in various ecological regions of Nepal. Scrub typhus is one of the neglected tropical diseases in Nepal. Patients with acute febrile illness should be investigated for scrub typhus with high priority. There is an urgent need of reliable and affordable diagnostic tests at all level of health facilities of Nepal. Surveillance and public health awareness about the disease transmission and preventive measures needs to be initiated.
Distribution of Eschar in Pediatric Scrub Typhus.
Rose, Winsley; Rajan, Roshni J; Punnen, Anu; Ghosh, Urmi
2016-10-01
Identifying an eschar in scrub typhus is useful for initiation of prompt and appropriate antibiotic therapy. The distribution of eschars in all children scrub typhus over a 5 year period is described. Of 431 children admitted with scrub typhus, eschars were present in 176 (40.8%) children with the following distribution: head, face and neck, 33 (19.1%); axillae, 37 (21%); chest and abdomen, 21 (11.9%); genitalia, inguinal region and buttocks, 58 (33%); back, 8 (4.5%); upper extremities, 13 (7.4%); and lower extremities, 5 (2.8%). The commonest sites of eschars were scrotum (27 of 106; 25.5%) and axillae (15 of 106; 14.2%) in males and axillae (22 of 70; 31.4%) and groin (16 of 70; 22.9%) in females. Eschars were seen within skin folds in 100 of 176 (56.8%) children. Children should be carefully examined for the presence of eschar especially in the skin folds of the genitalia, axillae and groin to make an early diagnosis of scrub typhus. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
RPC gas recovery by open loop method
Energy Technology Data Exchange (ETDEWEB)
Joshi, Avinash [Alpha Pneumatics, 11, Krishna Kutir, Madanlal Dhigra Road, Panch Pakhadi (India)], E-mail: alpha_pneumatics@hotmail.com
2009-05-01
RPC detectors require to be flushed with small but continuous flow of gas mixture. Dealing with large number of detectors, gas consumption to very large volumes. Gas flow is a running expense and constituent gases are too expensive to be treated as consumables. Exhaust gas mixture from detectors is a potential environmental hazard if discharged directly into the atmosphere. Storage of gases on a large scale also leads to inventory- and safety-related problems. A solution to these problems is the recovery and reuse of exhaust gas mixture from RPC detectors. Close loop method employs recirculation of exhausted gas mixture after purification, analysis and addition of top-up quantities. In open loop method, under consideration here, individual component gases are separated from gas mixture and reused as source. During open loop process, gases liquefiable at low pressures are separated from ones liquefiable at high pressure. The gas phase components within each group are successively separated by either fractional condensation or gravity separation. Gas mixture coming from RPC exhaust is first desiccated by passage through molecular sieve adsorbent type (3A+4A). Subsequent scrubbing over basic activated alumina removes toxic and acidic contaminants such as S{sub 2}F{sub 10} produced during corona (arcing) discharge. In the first stage of separation isobutane and freon are concentrated by diffusion and liquefied by fractional condensation by cooling upto -30 deg. C. Liquefied gases are returned to source tanks. In the second stage of separation, argon and sulphur hexafluoride, the residual gases, are concentrated by settling due to density difference. SF{sub 6} is stored for recovery by condensation at high pressure while argon is further purified by thermal cracking of crossover impurities at 1000 deg. C followed by wet scrubbing.
RPC gas recovery by open loop method
International Nuclear Information System (INIS)
Joshi, Avinash
2009-01-01
RPC detectors require to be flushed with small but continuous flow of gas mixture. Dealing with large number of detectors, gas consumption to very large volumes. Gas flow is a running expense and constituent gases are too expensive to be treated as consumables. Exhaust gas mixture from detectors is a potential environmental hazard if discharged directly into the atmosphere. Storage of gases on a large scale also leads to inventory- and safety-related problems. A solution to these problems is the recovery and reuse of exhaust gas mixture from RPC detectors. Close loop method employs recirculation of exhausted gas mixture after purification, analysis and addition of top-up quantities. In open loop method, under consideration here, individual component gases are separated from gas mixture and reused as source. During open loop process, gases liquefiable at low pressures are separated from ones liquefiable at high pressure. The gas phase components within each group are successively separated by either fractional condensation or gravity separation. Gas mixture coming from RPC exhaust is first desiccated by passage through molecular sieve adsorbent type (3A+4A). Subsequent scrubbing over basic activated alumina removes toxic and acidic contaminants such as S 2 F 10 produced during corona (arcing) discharge. In the first stage of separation isobutane and freon are concentrated by diffusion and liquefied by fractional condensation by cooling upto -30 deg. C. Liquefied gases are returned to source tanks. In the second stage of separation, argon and sulphur hexafluoride, the residual gases, are concentrated by settling due to density difference. SF 6 is stored for recovery by condensation at high pressure while argon is further purified by thermal cracking of crossover impurities at 1000 deg. C followed by wet scrubbing.
International Nuclear Information System (INIS)
Kindig, J.K.
1992-01-01
More than 502 million tons - 65 percent of all coal shipped to utilities in 1990 - were above 1.2 pounds of sulfur dioxide per million Btu. Most of the coal, even though cleaned in conventional coal preparation plants, still does not meet the emission limitation the Clean Air Act Amendments mandate for the year 2000. To cope with this fact, most utilities plan to switch to low sulfur (western U.S. or Central Appalachian) coal or install scrubbers. Both solutions have serous drawbacks. Switching puts local miners out of work and weakens the economy in the utility's service territory. Scrubbing requires a major capital expenditure by the utility. Scrubbers also increase the operating complexity and costs of the generating station and produce yet another environmental problem, scrubber sludge. Employing three new cost-effective technologies developed by Customer Coals International (CCl), most non-compliance coals east of the Mississippi River can be brought into year-2000 compliance. The compliance approach employed, depends upon the characteristics of the raw coal. Three types of raw coal are differentiated, based upon the amount of organic sulfur in the coals and the ease (or difficultly) of liberating the pyrite. They are: Low organic sulfur content and pyrite that liberates easily. Moderate organic sulfur content and pyrite that liberates easily. High organic sulfur content or the pyrite liberates with difficulty. In this paper examples of each type of raw coal are presented below, and the compliance approach employed for each is described. The names of the beneficiated coal products produced from each type of raw coal give above are: Carefree Coal, Self-Scrubbing Coal and Dry-Scrubbing Coal
Clinical manifestations of scrub typhus.
Rajapakse, Senaka; Weeratunga, Praveen; Sivayoganathan, Sriharan; Fernando, Sumadhya Deepika
2017-02-01
The mite-borne rickettsial zoonosis scrub typhus is widely prevalent in parts of Southeast and Far East Asia, and northern Australia. The disease is an acute febrile illness, associated with rash and often an eschar, which responds dramatically to treatment with antibiotics. In some cases it results in a serious illness leading to multiple organ involvement and death. The disease manifestations are thought to result from a systemic vasculitis, caused by both direct effects of the organisms as well as an exaggerated immune response, although little is understood about its pathogenesis. A wide spectrum of clinical manifestations, affecting nearly every organ system, have been described with scrub typhus. Some of these manifestations are serious and life threatening. In this systematic review, we summarise the typical and atypical manifestations of scrub typhus reported in the literature. Awareness of these unusual manifestations will hopefully guide clinicians towards diagnosing the condition early, and initiating early appropriate antibiotics and other supportive measures. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
A review of the global epidemiology of scrub typhus.
Xu, Guang; Walker, David H; Jupiter, Daniel; Melby, Peter C; Arcari, Christine M
2017-11-01
Scrub typhus is a serious public health problem in the Asia-Pacific area. It threatens one billion people globally, and causes illness in one million people each year. Caused by Orientia tsutsugamushi, scrub typhus can result in severe multiorgan failure with a case fatality rate up to 70% without appropriate treatment. The antigenic heterogeneity of O. tsutsugamushi precludes generic immunity and allows reinfection. As a neglected disease, there is still a large gap in our knowledge of the disease, as evidenced by the sporadic epidemiologic data and other related public health information regarding scrub typhus in its endemic areas. Our objective is to provide a systematic analysis of current epidemiology, prevention and control of scrub typhus in its long-standing endemic areas and recently recognized foci of infection.
Activation of the coagulation cascade in patients with scrub typhus.
Lee, Hee-Jeong; Park, Chi-Young; Park, Sang-Gon; Yoon, Na-Ra; Kim, Dong-Min; Chung, Choon-Hae
2017-09-01
This retrospective study aimed to evaluate the levels of coagulation factors and presence of disseminated intravascular coagulation (DIC) in patients with scrub typhus. We included patients confirmed to have scrub typhus at the Chosun University Hospital between September 2004 and December 2009. The DIC scores were evaluated in 365 patients and 36 healthy controls. The median concentrations of fibrinogen, d-dimer, and fibrin/fibrinogen degradation products (FDP) were compared between patients and healthy controls (pscrub typhus had longer prothrombin time and lower platelet counts than the controls. Major bleeding was observed in 18/365 patients with scrub typhus. Fifty-one (14.0%) patients presented with severe complications of scrub typhus. Overt DIC and thrombocytopenia (scrub typhus had overt DIC, as defined by the International Society on Thrombosis and Hemostasis DIC score (DIC1) and the DIC-scoring template with a fibrinogen/C-reactive protein-ratio (DIC2), respectively. Three (16.7%) and 10 (55.6%) patients with bleeding had overt DIC, as defined by the DIC1 and DIC2, respectively. Seven (13.7%) and 26 (51%) patients with severe illness had overt DIC, as defined by DIC1 and DIC2, respectively. In conclusion, activation of the coagulation system is an important feature of scrub typhus and is correlated with severe disease, including bleeding. This is the first study to report a relationship between DIC and scrub typhus. Copyright © 2017 Elsevier Inc. All rights reserved.
Scrub Typhus among Pediatric Patients in Dambadeniya:A Base Hospital in Sri Lanka
De Silva, Nalika; Wijesundara, Sarojini; Liyanapathirana, Veranja; Thevanesam, Vasanthi; Stenos, John
2012-01-01
Data on pediatric scrub typhus is uncommon in Sri Lanka and other countries. The objective of this study was to identify the clinical features of patients with scrub typhus at a Base Hospital in Sri Lanka. Sixty patients presenting with suspected scrub typhus were included in the study. Their blood samples were tested for the presence of antibodies against rickettsioses using the reference method. Twenty patients had confirmed scrub typhus and 24 had possible scrub typhus. Their clinical feat...
Scrub typhus: radiological and clinical findings in abdominopelvic involvement.
Kim, Kun Yung; Song, Ji Soo; Park, Eun Hae; Jin, Gong Yong
2017-03-01
To describe the clinical and radiological findings of abdominopelvic involvement in scrub typhus. Abdominopelvic computed tomography (CT) of 78 patients with scrub typhus were evaluated by two readers. The presence of gallbladder wall thickening, arterial inhomogeneous enhancement of the liver, periportal edema, splenic infarction, hepatomegaly, splenomegaly, ascites, pleural effusion, and sites of lymphadenopathy were evaluated. Patients were divided into four clinical subgroups according to laboratory findings. Association between imaging findings and subgroups was analyzed by Chi squared test or Fisher's exact test. The most common CT finding was hepatomegaly (74.4%), followed by splenomegaly (66.7%). The majority of patients had at least three areas of abdominopelvic lymphadenopathy (71.8%). Pelvic lymphadenopathy was most commonly seen when eschar was found in the ipsilateral lower extremity (left, n = 5/7; right, n = 8/13). Significant association between hepatic dysfunction and perigastric lymphadenopathy was documented (p = 0.03). Scrub typhus has a spectrum of variable clinical and radiological findings mimicking those of acute hepatitis. Diffuse abdominopelvic lymphadenopathy involving the retroperitoneum and pelvic area may aid in early diagnosis of scrub typhus. Perigastric lymphadenopathy could be a sign of severe scrub typhus combined with hepatic dysfunction.
Impact of elevated CO2 on a Florida Scrub-oak Ecosystems
Energy Technology Data Exchange (ETDEWEB)
Drake, Bert G
2013-01-01
Since May of 1996, we have conducted an experiment in Florida Scrub Oak to determine the impact of elevated atmospheric CO2 and climate change on carbon, water, and nutrient cycling in this important terrestrial ecosystem. Florida scrub oak is the name for a collective of species occupying much of the Florida peninsula. The dominant tree species are oaks and the dwarf structure of this community makes it an excellent system in which to test hypotheses regarding the potential capacity of woody ecosystems to assimilate and sequester anthropogenic carbon. Scrub oak is fire dependent with a return cycle of 10-15 years, a time which would permit an experiment to follow the entire cycle. Our site is located on Cape Canaveral at the Kennedy Space Center, Florida. After burning in 1995, we built 16 open top chambers, half of which have been fumigated with pure CO2 sufficient to raise the concentration around the plants to 350 ppm above ambient. In the intervening 10 years we have non destructively measured biomass of shoots and roots, ecosystem gas exchange using chambers and eddy flux, leaf photosynthesis and respiration, soil respiration, and relevant environmental factors such as soil water availability, temperature, light, etc. The overwhelming result from analysis of our extensive data base is that elevated CO2 has had a profound impact on this ecosystem that, overall, has resulted in increased carbon accumulation in plant shoots, roots and litter. Our measurements of net ecosystem gas exchange also indicate that the ecosystem has accumulated carbon much in excess of the increased biomass or soil carbon suggesting a substantial export of carbon through the porous, sandy soil into the water table several meters below the surface. A major discovery is the powerful interaction between the stimulation of growth, photosynthesis, and respiration by elevated CO2 and other environmental factors particularly precipitation and nitrogen. Our measurements focused attention on
Energy Technology Data Exchange (ETDEWEB)
Kost, D.A.; Vimmerstedt, J.P.; Stehouwer, R.C.
1997-03-01
Establishment of vegetation on acid abandoned minelands requires modification of soil physical and chemical conditions. Covering the acid minesoil with topsoil or borrow soil is a common practice but this method may be restricted by availability of borrow soil and cause damage to the borrow site. An alternative approach is to use waste materials as soil amendments. There is a long history of using sewage sludge and fly ash as amendments for acid minesoils. Flue gas desulfurization (FGD) by-products are newer materials that are also promising amendments. Most flue gas sludges are mixtures of Calcium sulfate (CaSO{sub 4}), calcium sulfite (CaSO{sub 3}), calcium carbonate (CaCO{sub 3}), calcium hydroxide [Ca(OH){sub 2}], and fly ash. Some scrubbing processes produce almost pure gypsum (CaSO{sub 4}2H{sub 2}O). The primary purpose of the project is to evaluate two wet FGD by-products for effects on vegetation establishment and surface and ground water quality on an acid minesoil. One by-product from the Conesville, OH power plant (American Electric Power Service Corporation) contains primarily calcium sulfite and fly ash. The other by-product (Mg-gypsum FGD) from an experimental scrubber at the Zimmer power plant (Cincinnati Gas and Electric Company) is primarily gypsum with 4% magnesium hydroxide. These materials were compared with borrow soil and sewage sludge as minesoil amendments. Combinations of each FGD sludge with sewage sludge were also tested. This report summarizes two years of measurements of chemical composition of runoff water, ground water at two depths in the subsoil, soil chemical properties, elemental composition and yield of herbaceous ground cover, and elemental composition, survival and height of trees planted on plots treated with the various amendments. The borrow soil is the control for comparison with the other treatments.
International Nuclear Information System (INIS)
Kost, D.A.; Vimmerstedt, J.P.; Stehouwer, R.C.
1997-03-01
Establishment of vegetation on acid abandoned minelands requires modification of soil physical and chemical conditions. Covering the acid minesoil with topsoil or borrow soil is a common practice but this method may be restricted by availability of borrow soil and cause damage to the borrow site. An alternative approach is to use waste materials as soil amendments. There is a long history of using sewage sludge and fly ash as amendments for acid minesoils. Flue gas desulfurization (FGD) by-products are newer materials that are also promising amendments. Most flue gas sludges are mixtures of Calcium sulfate (CaSO 4 ), calcium sulfite (CaSO 3 ), calcium carbonate (CaCO 3 ), calcium hydroxide [Ca(OH) 2 ], and fly ash. Some scrubbing processes produce almost pure gypsum (CaSO 4 2H 2 O). The primary purpose of the project is to evaluate two wet FGD by-products for effects on vegetation establishment and surface and ground water quality on an acid minesoil. One by-product from the Conesville, OH power plant (American Electric Power Service Corporation) contains primarily calcium sulfite and fly ash. The other by-product (Mg-gypsum FGD) from an experimental scrubber at the Zimmer power plant (Cincinnati Gas and Electric Company) is primarily gypsum with 4% magnesium hydroxide. These materials were compared with borrow soil and sewage sludge as minesoil amendments. Combinations of each FGD sludge with sewage sludge were also tested. This report summarizes two years of measurements of chemical composition of runoff water, ground water at two depths in the subsoil, soil chemical properties, elemental composition and yield of herbaceous ground cover, and elemental composition, survival and height of trees planted on plots treated with the various amendments. The borrow soil is the control for comparison with the other treatments
Optimization of sodium bicarbonate injection for acid scrubbing in hospital waste incineration plant
International Nuclear Information System (INIS)
Rozainee, M.; Salleh, M.; Mutahharah, M.M.; Anwar Johari
2010-01-01
Optimization of sodium bicarbonate (NaHCO 3 ) injection for acid hydrochloric (HCl) scrubbing was conducted on a hospital waste incineration plant. The plant employs a rotary kiln system having burning capacity of 350 kg/h hospital waste (average calorific value of 17.4 MJ/kg) and is operated on a 24 hr/ day basis. Currently, NaHCO 3 injection rate is 25 kg/h as recommended by manufacturer to meet the Department of Environment (DOE) standard emission limit of 200 mg/Nm 3 HCl. Testing of HCl emission at various injection rates of 25, 20, 15 and 10 kg/ h results in HCl final concentration in the range of 0.58-7.13, 5.63-7.74, 0.07-2.99 and 3-28 mg/Nm 3 respectively. The results showed that NaHCO 3 injection rate as low as 10 kg/ h could still meet the HCl stipulated emission limit. Economic comparison between 25 and 10 kg/ h injection rates showed that total saving on NaHCO 3 and disposal of fly ash was RM 22,000 per month (equivalent to saving RM 260,000 per year) when using 10 kg/ h injection rate. It was concluded from the study that optimum injection rate would not only save cost and reduce wastage but also reduce bag house loading rate and prolong the life span of filter bags. (author)
Urbanization of scrub typhus disease in South Korea.
Park, Sang-Won; Ha, Na-Young; Ryu, Boyeong; Bang, Ji Hwan; Song, Hoyeon; Kim, Yuri; Kim, Gwanghun; Oh, Myoung-don; Cho, Nam-Hyuk; Lee, Jong-koo
2015-05-01
Scrub typhus is an endemic disease in Asia. It has been a rural disease, but indigenous urban cases have been observed in Seoul, South Korea. Urban scrub typhus may have a significant impact because of the large population. Indigenous urban scrub typhus was epidemiologically identified in Seoul, the largest metropolitan city in South Korea, using national notifiable disease data from 2010 to 2013. For detailed analysis of clinical features, patients from one hospital that reported the majority of cases were selected and compared to a historic control group. Chigger mites were prospectively collected in the city using a direct chigger mite-collecting trap, and identified using both phenotypic and 18S rDNA sequencing analyses. Their infection with Orientia tsutsugamushi was confirmed by sequencing the 56-kDa antigen gene. Eighty-eight cases of urban scrub typhus were determined in Seoul. The possible sites of infection were mountainous areas (56.8%), city parks (20.5%), the vicinity of one's own residence (17.0%), and riversides (5.7%). Eighty-seven chigger mites were collected in Gwanak mountain, one of the suspected infection sites in southern Seoul, and seventy-six (87.4%) of them were identified as Helenicula miyagawai and eight (9.2%) as Leptotrombidium scutellare. Pooled DNA extracted from H. miyagawai mites yielded O. tsutsugamushi Boryong strain. Twenty-six patients from one hospital showed low APACHE II score (3.4 ± 2.7), low complication rate (3.8%), and no hypokalemia. We identified the presence of indigenous urban scrub typhus in Seoul, and a subgroup of them had mild clinical features. The chigger mite H. miyagawai infected with O. tsutsugamushi within the city was found. In endemic area, urban scrub typhus needs to be considered as one of the differential febrile diseases and a target for prevention.
Chest radiographic manifestations of scrub typhus
Directory of Open Access Journals (Sweden)
KPP Abhilash
2016-01-01
Full Text Available Background and Rationale: Respiratory system involvement in scrub typhus is seen in 20–72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Materials and Methods: Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. Results: The study cohort contained 398 patients. Common presenting complaints included fever (100%, generalized myalgia (83%, headache (65%, dyspnea (54%, cough (24.3%, and altered sensorium (14%. Almost half of the patients (49.4% had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%, acute respiratory distress syndrome (14%, airspace opacity (10.5%, reticulonodular opacities (10.3%, peribronchial thickening (5.8%, and pulmonary edema (2%. Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89–33.16, invasive ventilation (OR: 18.07; 95% CI: 6.42–50.88, inotropes (OR: 8.76; 95% CI: 4.35–17.62, higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; P< 0.001, and higher mortality (OR: 4.63; 95% CI: 1.54–13.85. Conclusion: Almost half of the patients with scrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.
A study of muscle involvement in scrub typhus.
Kalita, Jayantee; Misra, Usha K; Mani, Vinita E; Mahadevan, Anita; Shankar, Susrala K
2015-01-15
Patients with scrub typhus often complain of myalgia, but a comprehensive study on muscle dysfunction is lacking. We therefore report the clinical, electromyographic and muscle biopsy findings in patients with scrub typhus. Consecutive patients with scrub typhus were included, and their clinical and laboratory findings were noted. The patients with myalgia or weakness and elevated serum creatine kinase (CK) were considered to have muscle involvement. Electromyography (EMG) and muscle biopsy were done in some patients. Patients were treated with doxycycline 200mg daily for 7 days, and their clinical and biochemical outcome on discharge and one month were evaluated. 13 out of 33 (39.4%) patients had muscle involvement and their CK levels ranged between 287 and 3166 (859 ± 829) U/L. EMG revealed short duration polyphasic potentials, and muscle histopathology revealed evidence of vasculitis. There were significant correlations between severity of weakness and CK levels (r = -0.6; p scrub typhus. Although muscle histopathology showed evidence of vasculitis, patients responded to doxycycline. Copyright © 2014 Elsevier B.V. All rights reserved.
Flotability Improvement of Ilmenite Using Attrition-Scrubbing as a Pretreatment Method
Directory of Open Access Journals (Sweden)
Jihua Zhai
2017-01-01
Full Text Available Flotation technology of the recovery and utilization of ilmenite from tailings of iron beneficiated in Panzhihua was investigated based on mineralogical study. The results of mineralogical study show that the main occurrence of the valuable mineral are liberated grains of ilmenite. Experimental results of flotation conditions show that attrition-scrubbing raw ores exhibit good flotability with higher recoveries and a slight decrease in grade compared to ores without attrition-scrubbing. Further, open-circuit experiments also prove the superiority of attrition-scrubbing raw ores. The results of closed-circuit experiments show that qualified ilmenite concentrate can be obtained and the yield, grade, and recovery are 22.26%, 47.06%, and 60.73%, respectively. Theoretical study and analysis show that there are two contributions to superior flotability for attrition-scrubbing samples. The first is that the attrition-scrubbing samples can uncover more ferrous ions on the newly-produced fresh ilmenite surface, resulting in the increase in active sites. The other is that in the process of attrition-scrubbing, the transformation of ferrous ions to ferric ions can be promoted.
Quality of surgical scrub in a heart hospital: Do not take it for granted
Directory of Open Access Journals (Sweden)
Leila Abdollahi
2017-09-01
Full Text Available Introduction: The role of scrub in the prevention of post-surgery infections is well-known. This study aimed to investigate the inputs and process of surgical scrub in operating rooms of the largest heart hospital of northwest Iran. Methods: This study took place with a before-after design as a clinical audit in 2014. A check list developed based on national and international standards of surgical hand scrub was used as the study instrument. Checklists were completed by observation of surgical team scrubbing in real situation. Descriptive statistics and graphs were used to describe the results. Results: A compliance degree with the standards for prerequisites, equipment, general items, process and time of scrub was observed as 58%, 55%, 33%, 68% and 22%, respectively. The compliance degree after the intervention was 72%, 66%, 66%, 85% and 61%, respectively. Improvement was observed in all studied aspects of scrub. The total score of compliance with the standards changed from 47% to 70%. The main issues were incorrect order of scrubbing the areas of the hands, incorrect way of scrubbing the arms, insufficient scrubbing the arms (not above elbow, and lack of awareness about hospital’s policy on scrub time. Conclusion: The results showed defects in the surgical scrub of the studied hospital and that the compliance with the standards can be improved by simple interventions. Periodical audit and observation of the scrub and then feedback is recommended.
Quality of surgical scrub in a heart hospital: Do not take it for granted.
Abdollahi, Leila; Tabrizi, Jafar Sadegh; Jodati, Ahmadreza; Safaie, Naser; Moradi-Joo, Mohammad; Daemi, Amin
2017-01-01
Introduction: The role of scrub in the prevention of post-surgery infections is well-known. This study aimed to investigate the inputs and process of surgical scrub in operating rooms of the largest heart hospital of northwest Iran. Methods: This study took place with a before-after design as a clinical audit in 2014. A check list developed based on national and international standards of surgical hand scrub was used as the study instrument. Checklists were completed by observation of surgical team scrubbing in real situation. Descriptive statistics and graphs were used to describe the results. Results: A compliance degree with the standards for prerequisites, equipment, general items, process and time of scrub was observed as 58%, 55%, 33%, 68% and 22%, respectively. The compliance degree after the intervention was 72%, 66%, 66%, 85% and 61%, respectively. Improvement was observed in all studied aspects of scrub. The total score of compliance with the standards changed from 47% to 70%. The main issues were incorrect order of scrubbing the areas of the hands, incorrect way of scrubbing the arms, insufficient scrubbing the arms (not above elbow), and lack of awareness about hospital's policy on scrub time. Conclusion: The results showed defects in the surgical scrub of the studied hospital and that the compliance with the standards can be improved by simple interventions. Periodical audit and observation of the scrub and then feedback is recommended.
Summary of INCO corrosion tests in power plant flue gas scrubbing processes
International Nuclear Information System (INIS)
Hoxie, E.C.; Tuffnell, G.W.
1976-01-01
Corrosion tests in a number of flue-gas desulfurization units have shown that carbon steel, low alloy steels, and Type 304L stainless steel are inadequate in the wet portions of the scrubbers. Type 316L stainless steel is sometimes subject to localized corrosive attack in scrubber environments with certain combinations of pH and chloride content. A corollary is that corrosion of Type 316L stainless steel might be controlled by control of scrubbing media pH and chloride content. Although an attempt was made to correlate the pitting and crevice corrosion obtained on the Type 316 stainless steel test samples with chloride and pH measurements, relatively wide scatter in the data indicated only a modest correlation. This is attributed to variations in local conditions, especially beneath deposits, that differ from the liquor samples obtained for analysis, to processing upsets, to temperature differences, and to some extent to inaccuracies in measurement of pH and chloride levels. The data do show, however, that molybdenum as an alloying element in stainless steels and high nickel alloys was very beneficial in conferring resistance to localized attack in scrubber environments. High nickel alloys containing appreciable amounts of molybdenum such as Hastelloy alloy C-276 and Inconel alloy 625 can be used for critical components. Chloride stress corrosion cracking (SCC) of austenitic stainless steels has generally not been a problem in FGD scrubbers, apparently because operating temperatures are comparatively low. An exception is reheater tubing where some failures have occurred because of elevated temperatures in conjunction with condensate that forms during shut-down periods or carryover of chloride laden mist from the scrubber. This problem can be overcome by proper alloy selection or maintaining dry conditions
Enhancement of the SPARC90 code to pool scrubbing events under jet injection regime
Energy Technology Data Exchange (ETDEWEB)
Berna, C., E-mail: ceberes@iie.upv.es [Instituto de Ingeniería Energética, Universitat Politècnica de València (UPV), Camino de Vera 14, 46022 Valencia (Spain); Escrivá, A.; Muñoz-Cobo, J.L. [Instituto de Ingeniería Energética, Universitat Politècnica de València (UPV), Camino de Vera 14, 46022 Valencia (Spain); Herranz, L.E., E-mail: luisen.herranz@ciemat.es [Unit of Nuclear Safety Research Division of Nuclear Fission, CIEMAT, Avda. Complutense 22, 28040 Madrid (Spain)
2016-04-15
Highlights: • Review of the most recent literature concerning submerged jets. • Emphasize all variables and processes occurring along the jet region. • Highlight the gaps of knowledge still existing related to submerged jets. • Enhancement of SPARC90-Jet to estimate aerosol removal under jet injection regime. • Validation of the SPARC90-Jet results against pool scrubbing experimental data. - Abstract: Submerged gaseous jets may have an outstanding relevance in many industrial processes and may be of particular significance in severe nuclear accident scenarios, like in the Fukushima accident. Even though pool scrubbing has been traditionally associated with low injection velocities, there are a number of potential scenarios in which fission product trapping in aqueous ponds might also occur under jet injection regime (like SGTR meltdown sequences in PWRs and SBO ones in BWRs). The SPARC90 code was developed to determine the fission product trapping in pools during severe accidents. The code assumes that carrier gas arrives at the water ponds at low or moderate velocities and it forms a big bubble that eventually detaches from the injection pipe. However, particle laden gases may enter the water at very high velocities resulting in a submerged gas jet instead. This work presents the fundamentals, major hypotheses and changes introduced into the code in order to estimate particle removal during gas injection in pools under the jet regime (SPARC90-Jet). A simplified and reliable approach to submerged jet hydrodynamics has been implemented on the basis of updated equations for jet hydrodynamics and aerosol removal, so that gas–liquid and droplet-particles interactions are described. The code modifications have been validated as far as possible. However, no suitable hydrodynamic tests have been found in the literature, so that an indirect validation has been conducted through comparisons against data from pool scrubbing experiments. Besides, this validation
Enhancement of the SPARC90 code to pool scrubbing events under jet injection regime
International Nuclear Information System (INIS)
Berna, C.; Escrivá, A.; Muñoz-Cobo, J.L.; Herranz, L.E.
2016-01-01
Highlights: • Review of the most recent literature concerning submerged jets. • Emphasize all variables and processes occurring along the jet region. • Highlight the gaps of knowledge still existing related to submerged jets. • Enhancement of SPARC90-Jet to estimate aerosol removal under jet injection regime. • Validation of the SPARC90-Jet results against pool scrubbing experimental data. - Abstract: Submerged gaseous jets may have an outstanding relevance in many industrial processes and may be of particular significance in severe nuclear accident scenarios, like in the Fukushima accident. Even though pool scrubbing has been traditionally associated with low injection velocities, there are a number of potential scenarios in which fission product trapping in aqueous ponds might also occur under jet injection regime (like SGTR meltdown sequences in PWRs and SBO ones in BWRs). The SPARC90 code was developed to determine the fission product trapping in pools during severe accidents. The code assumes that carrier gas arrives at the water ponds at low or moderate velocities and it forms a big bubble that eventually detaches from the injection pipe. However, particle laden gases may enter the water at very high velocities resulting in a submerged gas jet instead. This work presents the fundamentals, major hypotheses and changes introduced into the code in order to estimate particle removal during gas injection in pools under the jet regime (SPARC90-Jet). A simplified and reliable approach to submerged jet hydrodynamics has been implemented on the basis of updated equations for jet hydrodynamics and aerosol removal, so that gas–liquid and droplet-particles interactions are described. The code modifications have been validated as far as possible. However, no suitable hydrodynamic tests have been found in the literature, so that an indirect validation has been conducted through comparisons against data from pool scrubbing experiments. Besides, this validation
Janardhanan, Jeshina; Trowbridge, Paul; Varghese, George M
2014-12-01
Scrub typhus is an acute febrile illness that, if untreated, can result in considerable morbidity and mortality. One of the primary reasons for delays in the treatment of this potentially fatal infection is the difficulty in diagnosing the condition. Diagnosis is often complicated because of the combination of non-specific symptoms that overlap with other infections commonly found in endemic areas and the poor available diagnostics. In the majority of the endemic settings, diagnosis still relies on the Weil-Felix test, which is neither sensitive nor specific. Other methods of testing have become available, but at this time, these remain insufficient to provide the rapid point-of-care diagnostics that would be necessary to significantly change the management of this infection by providers in endemic areas. This article reviews the currently available diagnostic tools for scrub typhus and their utility in the clinical setting.
Meteorological factors and risk of scrub typhus in Guangzhou, southern China, 2006-2012.
Li, Tiegang; Yang, Zhicong; Dong, Zhiqiang; Wang, Ming
2014-03-12
Scrub typhus is becoming the most common vector born disease in Guangzhou, southern China. In this study, we aimed to examine the effect of weather patterns on the incidence of Scrub typhus in the subtropical city of Guangzhou for the period 2006-2012, and assist public health prevention and control measures. Scrub typhus reported cases during the period of 2006-2012 in Guangzhou were obtained from National Notifiable Disease Report System (NNDRS). Simultaneous meteorological data including temperature, relative humidity, atmospheric pressure, sunshine, and rainfall were obtained from the documentation of the Guangzhou Meteorological Bureau. A negative binomial regression was used to identify the relationship between meteorological variables and scrub typhus. Annual incidence rates of scrub typhus from 2006 to 2012 were 3.25, 2.67, 3.81, 4.22, 4.41, 5.12, and 9.75 (per 100 000) respectively. Each 1°C rise in temperature corresponded to an increase of 14.98% (95% CI 13.65% to 16.33%) in the monthly number of scrub typhus cases, while a 1 hPa rise in atmospheric pressure corresponded to a decrease in the number of cases by 8.03% (95% CI -8.75% to -7.31%). Similarly, a 1 hour rise in sunshine corresponded to an increase of 0.17% or 0.54%, and a 1 millimeter rise in rainfall corresponded to an increase of 0.05% or 0.10%, in the monthly number of scrub typhus cases, depending on the variables considered in the model. Our study provided evidence that climatic factors were associated with occurrence of scrub typhus in Guangzhou city, China. Temperature, duration of sunshine, and rainfall were positively associated with scrub typhus incidence, while atmospheric pressure was inversely associated with scrub typhus incidence. These findings should be considered in the prediction of future patterns of scrub typhus transmission.
Acute sensorineural hearing loss and severe otalgia due to scrub typhus
Directory of Open Access Journals (Sweden)
Kim Dong-Min
2009-10-01
Full Text Available Abstract Background Scrub typhus is an acute febrile illness caused by Orientia tsutsugamushi. Case presentations We encountered a patient with sensorineural hearing loss complicating scrub typhus, and three patients with scrub typhus who complained of otalgia, which was sudden onset, severe, paroxysmal, intermittent yet persistent pain lasting for several seconds, appeared within 1 week after the onset of fever and rash. The acute sensorineural hearing loss and otalgia were resolved after antibiotic administration. Conclusion When patients in endemic areas present with fever and rash and have sensorineural hearing loss or otalgia without otoscopic abnormalities, clinicians should suspect scrub typhus and consider empirical antibiotic therapy.
The clinical characteristics of pleural effusion in scrub typhus.
Kim, Hyung Ho; Chung, Jong-Hoon; Kim, Dong-Min; Yun, Na Ra; Lee, Jun; Kwon, Yong Eun; Yoon, Sung Ho; Lee, Seung Il; Han, Mi Ah
2016-06-11
The aim of this study is to identify the factors associated with the occurrence of pleural effusion and to investigate the characteristics of pleural effusion in scrub typhus. We conducted a retrospective analysis of the medical records of scrub typhus patients between January 2004 and December 2011 at Chosun University Hospital in South Korea. A total of 445 scrub typhus patients were divided into the following two groups: without (n = 352) or with pleural effusion (n = 93). The data of 18 scrub typhus patients who underwent thoracentesis were summarized. Multivariate analysis demonstrated that the following factors were associated with the occurrence of pleural effusion in scrub typhus: older age (odds ratio [OR] = 1.029, P = 0.037, confidence interval [CI] = 1.002-1.056); male gender (OR = 1.924, P = 0.020, CI = 1.109-3.340); presence of heart failure (OR = 2.628, P = 0.039, CI = 1.052-6.565); and lower albumin (OR = 0.107, P ≤ 0.001, CI = 0.058-0.196). Most pleural effusion presentations were bilateral (88 %) and small (91 %). The effusion had transudate characteristics in 7 patients and exudate characteristics in 11 patients based on Light's criteria. This study provided the first data regarding the following four independent risk factors associated with the occurrence of pleural effusion: older age; male gender; the presence of heart failure; and lower albumin. The pleural effusion presentations in scrub typhus patients were bilateral and small in most cases, with transudate and/or exudate characteristics.
Rouwet, Dmitri
2016-04-01
Tracking variations in the chemical composition, water temperature and pH of brines from peak-activity crater lakes is the most obvious way to forecast phreatic activity. Volcano monitoring intrinsically implies a time window of observation that should be synchronised with the kinetics of magmatic processes, such as degassing and magma intrusion. To decipher "how much time ago" a variation in degassing regime actually occurred before eventually being detected in a crater lake is key, and depends on the lake water residence time. The above reasoning assumes that gas is preserved as anions in the lake water (SO4, Cl, F anions), in other words, that scrubbing of acid gases is complete and irreversible. Less is true. Recent work has confirmed, by direct MultiGas measurement from evaporative plumes, that even the strongest acid in liquid medium (i.e. SO2) degasses from hyper-acidic crater lakes. The less strong acid HCl has long been recognised as being more volatile than hydrophyle in extremely acidic solutions (pH near 0), through a long-term steady increase in SO4/Cl ratios in the vigorously evaporating crater lake of Poás volcano. We now know that acidic gases flush through hyper-acidic crater lake brines, but we don't know to which extend (completely or partially?), and with which speed. The chemical composition hence only reflects a transient phase of the gas flushing through the lake. In terms of volcanic surveillance this brings the advantage that the monitoring time window is definitely shorter than defined by the water chemistry, but yet, we do not know how much shorter. Empirical experiments by Capaccioni et al. (in press) have tried to tackle this kinetic problem for HCl degassing from a "lab-lake" on the short-term (2 days). With this state of the art in mind, two new monitoring strategies can be proposed to seek for precursory signals of phreatic eruptions from crater lakes: (1) Tracking variations in gas compositions, fluxes and ratios between species in
Scrub Typhus: An Emerging Threat
Chakraborty, Sayantani; Sarma, Nilendu
2017-01-01
Scrub typhus is caused by Orientia tsutsugamushi (formerly Rickettsia) and is transmitted to humans by an arthropod vector of the Trombiculidae family (Leptotrombidium deliense and L. akamushi). It is the most common re-emerging Rickettsial infection in India and many other South East Asian countries. In fact, scrub typhus is confined geographically to the Asia Pacific region, a billion people are at risk and nearly a million cases are reported every year. Scrub typhus appears particularly to be distributed in the tsutsugamushi triangle which is distributed over a very wide area of 13 million km2 bound by Japan in the east, through China, the Philippines, tropical Australia in the south, and west through India, Pakistan, possibly to Tibet to Afghanistan, and southern parts of the USSR in the north. Eschar is the characteristic lesion that starts as a vesicular lesion at the site of mite feeding. Later, an ulcer forms with black necrotic center and an erythematous border along with regional lymphadenopathy. Other features are fever, maculopapular rash starting from the trunk, and spreading to the limbs. It may affect the central nervous system, cardiovascular system, renal, respiratory, and gastrointestinal systems. Serious complication in the form of myocarditis, pneumonia, meningoencephalitis, acute renal failure, gastrointestinal bleeding, and even acute respiratory distress syndrome may develop. Tetracycline or chloramphenicol remains the main stay of therapy. PMID:28979009
Chest radiographic manifestations of scrub typhus.
Abhilash, Kpp; Mannam, P R; Rajendran, K; John, R A; Ramasami, P
2016-01-01
Respiratory system involvement in scrub typhus is seen in 20-72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. The study cohort contained 398 patients. Common presenting complaints included fever (100%), generalized myalgia (83%), headache (65%), dyspnea (54%), cough (24.3%), and altered sensorium (14%). Almost half of the patients (49.4%) had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%), acute respiratory distress syndrome (14%), airspace opacity (10.5%), reticulonodular opacities (10.3%), peribronchial thickening (5.8%), and pulmonary edema (2%). Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89-33.16), invasive ventilation (OR: 18.07; 95% CI: 6.42-50.88), inotropes (OR: 8.76; 95% CI: 4.35-17.62), higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; Pscrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.
Solubility of flue gas components in NaOH based scrubber solutions
Energy Technology Data Exchange (ETDEWEB)
Sandelin, K; Backman, R
1997-11-01
The work reported here is a thermodynamic study on the solubility of flue gas components in aqueous solutions containing sodium salts. The result of the work is an equilibrium model. The model presented here includes sodium hydroxide and sodium salts that makes it possible to study simultaneous absorption of flue gas components in alkaline scrubber solutions. The model is applied on the absorption of a flue gas into a NaOH scrubber solution. The calculations show that it is possible to simultaneously absorb sulfur dioxide, sulfuric acid, and ammonia without carbon dioxide co-absorption. The calculations also show that gaseous NO and N{sub 2}O cannot be scrubbed unless they are oxidized to nitrate or reduced to ammonia. (author) SIHTI 2 Research Programme. 59 refs.
Severe Fever with Thrombocytopenia Syndrome in Patients Suspected of Having Scrub Typhus.
Wi, Yu Mi; Woo, Hye In; Park, Dahee; Lee, Keun Hwa; Kang, Cheol-In; Chung, Doo Ryeon; Peck, Kyong Ran; Song, Jae-Hoon
2016-11-01
To determine prevalence of severe fever with thrombocytopenia syndrome in South Korea, we examined serum samples from patients with fever and insect bite history in scrub typhus-endemic areas. During the 2013 scrub typhus season, prevalence of this syndrome among patients suspected of having scrub typhus was high (23.0%), suggesting possible co-infection.
Duodenal perforation precipitated by scrub typhus
Directory of Open Access Journals (Sweden)
Raghunath Rajat
2015-01-01
Full Text Available Scrub typhus is an acute febrile illness usually presenting with fever, myalgia, headache, and a pathognomonic eschar. Severe infection may lead to multiple organ failure and death. Gastrointestinal tract involvement in the form of gastric mucosal erosions and ulcerations owing to vasculitis resulting in gastrointestinal bleeding is common. This process may worsen a pre-existent asymptomatic peptic ulcer, causing duodenal perforation, and present as an acute abdomen requiring surgical exploration. We report the case of a patient with no previous symptoms or risk factors for a duodenal ulcer, who presented with an acute duodenal perforation, probably precipitated by scrub typhus infection.
Energy Technology Data Exchange (ETDEWEB)
Krischan, J., E-mail: jutta_krischan@hotmail.com [Vienna University of Technology, Institute of Chemical Engineering, Getreidemarkt 9/166, 1060 Vienna (Austria); Makaruk, A., E-mail: aleksander.makaruk@tuwien.ac.at [Vienna University of Technology, Institute of Chemical Engineering, Getreidemarkt 9/166, 1060 Vienna (Austria); Harasek, M., E-mail: michael.harasek@tuwien.ac.at [Vienna University of Technology, Institute of Chemical Engineering, Getreidemarkt 9/166, 1060 Vienna (Austria)
2012-05-15
Highlights: Black-Right-Pointing-Pointer Alkaline oxidative scrubbing proved for biogas desulfurization Black-Right-Pointing-Pointer Effect of operating conditions on hydrogen sulfide removal efficiency. Black-Right-Pointing-Pointer Minimization of caustic and oxidant consumption. Black-Right-Pointing-Pointer Process control via pH, redox potential and conductivity measurement. Black-Right-Pointing-Pointer Investigation of long-term behavior of pilot plant operation. - Abstract: Reliable and selective removal of hydrogen sulfide (H{sub 2}S) is an essential part of the biogas upgrading procedure in order to obtain a marketable and competitive natural gas substitute for flexible utilization. A promising biogas desulfurization technology has to ensure high separation efficiency regardless of process conditions or H{sub 2}S load without the use or production of toxic or ecologically harmful substances. Alkaline oxidative scrubbing is an interesting alternative to existing desulfurization technologies and is investigated in this work. In experiments on a stirred tank reactor and a continuous scrubbing column in laboratory-scale, H{sub 2}S was absorbed from a gas stream containing large amounts of carbon dioxide (CO{sub 2}) into an aqueous solution prepared from sodium hydroxide (NaOH), sodium bicarbonate (NaHCO{sub 3}) and hydrogen peroxide (H{sub 2}O{sub 2}). The influence of pH, redox potential and solution aging on the absorption efficiency and the consumption of chemicals was investigated. Because of the irreversible oxidation reactions of dissolved H{sub 2}S with H{sub 2}O{sub 2}, high H{sub 2}S removal efficiencies were achieved while the CO{sub 2} absorption was kept low. At an existing biogas upgrading plant an industrial-scale pilot scrubber was constructed, which efficiently desulfurizes 180 m{sup 3}/h of raw biogas with an average removal efficiency of 97%, even at relatively high and strongly fluctuating H{sub 2}S contents in the crude gas.
International Nuclear Information System (INIS)
Krischan, J.; Makaruk, A.; Harasek, M.
2012-01-01
Highlights: ► Alkaline oxidative scrubbing proved for biogas desulfurization ► Effect of operating conditions on hydrogen sulfide removal efficiency. ► Minimization of caustic and oxidant consumption. ► Process control via pH, redox potential and conductivity measurement. ► Investigation of long-term behavior of pilot plant operation. - Abstract: Reliable and selective removal of hydrogen sulfide (H 2 S) is an essential part of the biogas upgrading procedure in order to obtain a marketable and competitive natural gas substitute for flexible utilization. A promising biogas desulfurization technology has to ensure high separation efficiency regardless of process conditions or H 2 S load without the use or production of toxic or ecologically harmful substances. Alkaline oxidative scrubbing is an interesting alternative to existing desulfurization technologies and is investigated in this work. In experiments on a stirred tank reactor and a continuous scrubbing column in laboratory-scale, H 2 S was absorbed from a gas stream containing large amounts of carbon dioxide (CO 2 ) into an aqueous solution prepared from sodium hydroxide (NaOH), sodium bicarbonate (NaHCO 3 ) and hydrogen peroxide (H 2 O 2 ). The influence of pH, redox potential and solution aging on the absorption efficiency and the consumption of chemicals was investigated. Because of the irreversible oxidation reactions of dissolved H 2 S with H 2 O 2 , high H 2 S removal efficiencies were achieved while the CO 2 absorption was kept low. At an existing biogas upgrading plant an industrial-scale pilot scrubber was constructed, which efficiently desulfurizes 180 m 3 /h of raw biogas with an average removal efficiency of 97%, even at relatively high and strongly fluctuating H 2 S contents in the crude gas.
Risk factors associated with severe scrub typhus in Shandong, northern China.
Zhang, Luyan; Zhao, Zhongtang; Bi, Zhenwang; Kou, Zengqiang; Zhang, Meng; Yang, Li; Zheng, Li
2014-12-01
The aim of this study was to identify risk factors associated with severe scrub typhus, in order to provide a reference for clinical decision-making. A case-control study was conducted of scrub typhus patients who presented at local hospitals between 2010 and 2013. In total, 46 patients with severe scrub typhus complications (cases) and 194 without severe complications (controls) were included. There were significant differences in the duration of illness before effective antibiotic therapy, lymphadenopathy, rash, blood platelet count, white blood cell (WBC) count, percentage neutrophils, and percentage lymphocytes between the case and control groups. Multivariate analysis demonstrated that the following four factors were significantly associated with the severe complications of scrub typhus: (1) duration of illness before effective antibiotic therapy (odds ratio (OR) 2.287, 95% confidence interval (CI) 1.096-4.770); (2) the presence of a rash (OR 3.694, 95% CI 1.300-10.495); (3) lymphadenopathy (OR 2.438, 95% CI 1.090-5.458); (4) blood platelet count scrub typhus. When scrub typhus patients present with a rash, lymphadenopathy, or blood platelet count <100×10(9)/l, clinicians should be alert to the appearance of severe complications. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Spatial Distribution Analysis of Scrub Typhus in Korea
Jin, Hong Sung; Chu, Chaeshin; Han, Dong Yeob
2013-01-01
Objective: This study analyzes the spatial distribution of scrub typhus in Korea. Methods: A spatial distribution of Orientia tsutsugamushi occurrence using a geographic information system (GIS) is presented, and analyzed by means of spatial clustering and correlations. Results: The provinces of Gangwon-do and Gyeongsangbuk-do show a low incidence throughout the year. Some districts have almost identical environmental conditions of scrub typhus incidence. The land use change of districts does...
Clinical Profile of Scrub Typhus in Pregnancy in Sub-Himalayan Region.
Kumar, Ritesh; Thakur, Surinder; Bhawani, Rajesh; Kanga, Anil; Ranjan, Asha
2016-10-01
Scrub typhus is rare in pregnancy, but it has now become an important cause of febrile illness in pregnancy in sub-Himalayan region of India. Only a few case reports have been published so far, and they show adverse maternal and fetal outcomes. No consensus has been reached till now regarding treatment. All the pregnant patients irrespective of period of gestation admitted with febrile illness with positive IgM ELISA for scrub typhus with or without eschar were included. The clinical profile was observed using a detailed history of symptoms, travel, recreation, agricultural activities, treatment record prior to admission, and a detailed examination, and the treatment outcome was noted. Fever workup including cultures, CXR, CSF analysis, serology for scrub was done. IgM scrub typhus was done by kit method manufactured by InBios Intertational, Inc. We observed in total 14 pregnant patients out of which eight were in the the second trimester and six were in the third trimester. The clinical features of the disease observed for pregnant females were the same as for nonpregnant females. There was no difference in the severity of scrub typhus between pregnant and nonpregnant women. No mortality was found in these patients. On follow-up, they had normal peripartum and postpartum periods. All were treated with azithromycin 500 mg once a day for 5 days. Although rare, scrub typhus should be considered in differential diagnosis of fever in pregnant patients especially in scrub season. Azithromycin should be the drug of choice in pregnancy as it has no adverse effect on fetus and pregnancy outcome.
International Nuclear Information System (INIS)
Balaji, Subramanian; Muthuraman, Govindan; Moon, Il Shik
2015-01-01
Highlights: • Electrolytic production of peroxydisulfuric acid (PDSA) with BDD anode. • PDSA yield enhanced by proper selection of cathode material. • Electro-scrubbing of SO_2 in presence of PDSA monitored by online FTIR analyzer. • 100% SO_2 removal was achieved for 25 ppm and 50 ppm in less than 10 min. - Abstract: Peroxydisulfuric acid oxidant (H_2S_2O_8) was electro-generated using boron doped diamond (BDD) anode in an undivided electrolytic cell under the optimized conditions and used for the oxidative removal of gaseous SO_2. The influence of the nature of cathode material on the formation yield of H_2S_2O_8 was investigated with Ti, Pt, Zr and DSA electrodes in a flow type electrolytic cell under batch recirculation mode. Among the various cathodes employed Ti exhibited a good performance and the formation yield was nearly doubled (0.19 M) compared to the reported value of 0.07 M. The optimization of electrode area ratio between the anode and cathode brought out the fact that for nearly 8 times smaller Ti cathode (8.75:1) the achieved yield was ∼65% higher than the 1:1 ratio of anode and cathode. The highest concentration of 6.8% (0.48 M) H_2S_2O_8 was seen for 35 cm"2 BDD anode with 4 cm"2 Ti at 20 °C with the measured redox potential value of +1200 mV. The oxidative removal of SO_2 in an electro-scrubbing column attached to the online production of peroxydisulfuric acid under the optimized conditions of cell parameters shows that SO_2 removal efficiency was nearly 100% for 25 and 50 ppm inlet concentrations and 96% for 100 ppm at the room temperature of 25 °C.
Genotype Diversity and Distribution of Orientia tsutsugamushi Causing Scrub Typhus in Thailand
2011-07-01
Society for Microbiology. All Rights Reserved. Genotype Diversity and Distribution of Orientia tsutsugamushi Causing Scrub Typhus in Thailand" Toon...2011 Scrub typhus , caused by antigenically disparate isolates of Orientia tsutsugamushi, is a widely distributed mite-borne human disease in the Asia...evaluation of scrub typhus - specific diagnostic assays and vaccines. Using indirect immunoHuorescence assays (IF A) and PCR assays, 0. tsutsugamushi
Use of Multiplex Real-Time PCR To Diagnose Scrub Typhus.
Tantibhedhyangkul, Wiwit; Wongsawat, Ekkarat; Silpasakorn, Saowaluk; Waywa, Duangdao; Saenyasiri, Nuttawut; Suesuay, Jintapa; Thipmontree, Wilawan; Suputtamongkol, Yupin
2017-05-01
Scrub typhus, caused by Orientia tsutsugamushi , is a common cause of acute undifferentiated febrile illness in the Asia-Pacific region. However, its nonspecific clinical manifestation often prevents early diagnosis. We propose the use of PCR and serologic tests as diagnostic tools. Here, we developed a multiplex real-time PCR assay using hydrolysis (TaqMan) probes targeting O. tsutsugamushi 47-kDa, groEL , and human interferon beta (IFN-β gene) genes to improve early diagnosis of scrub typhus. The amplification efficiency was higher than 94%, and the lower detection limit was 10 copies per reaction. We used a human gene as an internal DNA quality and quantity control. To determine the sensitivity of this PCR assay, we selected patients with confirmed scrub typhus who exhibited a clear 4-fold increase in the level of IgG and/or IgM. The PCR assay result was positive in 45 of 52 patients, indicating a sensitivity of 86.5% (95% confidence interval [CI]: 74.2 to 94.4). The PCR assessment was negative for all 136 non-scrub typhus patients, indicating a specificity of 100% (95% CI: 97.3 to 100). In addition, this test helped diagnose patients with inconclusive immunofluorescence assay (IFA) results and using single blood samples. In conclusion, the real-time PCR assay proposed here is sensitive and specific in diagnosing scrub typhus. Combining PCR and serologic tests will improve the diagnosis of scrub typhus among patients presenting with acute febrile illness. Copyright © 2017 American Society for Microbiology.
Directory of Open Access Journals (Sweden)
Animesh Ray
2016-01-01
Full Text Available We describe a middle aged previoulsy healthy female patient who presented with clinical features suggestive of acute heart failure. Investigations revealed very high NT pro-BNP, right heart enlargement, bilateral pulmonary alveolar edema and bilateral pleural effusion. In view of falling platelet counts and exudative pleural effusion inflammatory/infective causes were considered. Her Weil Felix test was strongly positive and IgM for scrub typhus also returned positive. She was started on doxycycline to which there was dramatic improvement. Thus in this case scrub typhus infection presented as acute right heart failure and the cause seemed elusive at the outset.We also systematically reviewed the existing literature on cardio-pulmonary manifestations of scrub typhus infection.
2013-01-01
Background The Taiwan area comprises the main island of Taiwan and several small islands located off the coast of the Southern China. The eastern two-thirds of Taiwan are characterized by rugged mountains covered with tropical and subtropical vegetation. The western region of Taiwan is characterized by flat or gently rolling plains. Geographically, the Taiwan area is diverse in ecology and environment, although scrub typhus threatens local human populations. In this study, we investigate the effects of seasonal and meteorological factors on the incidence of scrub typhus infection among 10 local climate regions. The correlation between the spatial distribution of scrub typhus and cultivated forests in Taiwan, as well as the relationship between scrub typhus incidence and the population density of farm workers is examined. Methods We applied Pearson’s product moment correlation to calculate the correlation between the incidence of scrub typhus and meteorological factors among 10 local climate regions. We used the geographically weighted regression (GWR) method, a type of spatial regression that generates parameters disaggregated by the spatial units of analysis, to detail and map each regression point for the response variables of the standardized incidence ratio (SIR)-district scrub typhus. We also applied the GWR to examine the explanatory variables of types of forest-land use and farm worker density in Taiwan in 2005. Results In the Taiwan Area, scrub typhus endemic areas are located in the southeastern regions and mountainous townships of Taiwan, as well as the Pescadore, Kinmen, and Matou Islands. Among these islands and low-incidence areas in the central western and southwestern regions of Taiwan, we observed a significant correlation between scrub typhus incidence and surface temperature. No similar significant correlation was found in the endemic areas (e.g., the southeastern region and the mountainous area of Taiwan). Precipitation correlates positively
Mercury sorbent delivery system for flue gas
Klunder,; Edgar, B [Bethel Park, PA
2009-02-24
The invention presents a device for the removal of elemental mercury from flue gas streams utilizing a layer of activated carbon particles contained within the filter fabric of a filter bag for use in a flue gas scrubbing system.
A Spatiotemporal Database to Track Human Scrub Typhus Using the VectorMap Application.
Directory of Open Access Journals (Sweden)
Daryl J Kelly
2015-12-01
Full Text Available Scrub typhus is a potentially fatal mite-borne febrile illness, primarily of the Asia-Pacific Rim. With an endemic area greater than 13 million km2 and millions of people at risk, scrub typhus remains an underreported, often misdiagnosed febrile illness. A comprehensive, updatable map of the true distribution of cases has been lacking, and therefore the true risk of disease within the very large endemic area remains unknown. The purpose of this study was to establish a database and map to track human scrub typhus. An online search using PubMed and the United States Armed Forces Pest Management Board Literature Retrieval System was performed to identify articles describing human scrub typhus cases both within and outside the traditionally accepted endemic regions. Using World Health Organization guidelines, stringent criteria were used to establish diagnoses for inclusion in the database. The preliminary screening of 181 scrub typhus publications yielded 145 publications that met the case criterion, 267 case records, and 13 serosurvey records that could be georeferenced, describing 13,739 probable or confirmed human cases in 28 countries. A map service has been established within VectorMap (www.vectormap.org to explore the role that relative location of vectors, hosts, and the pathogen play in the transmission of mite-borne scrub typhus. The online display of scrub typhus cases in VectorMap illustrates their presence and provides an up-to-date geographic distribution of proven scrub typhus cases.
A Spatiotemporal Database to Track Human Scrub Typhus Using the VectorMap Application.
Kelly, Daryl J; Foley, Desmond H; Richards, Allen L
2015-12-01
Scrub typhus is a potentially fatal mite-borne febrile illness, primarily of the Asia-Pacific Rim. With an endemic area greater than 13 million km2 and millions of people at risk, scrub typhus remains an underreported, often misdiagnosed febrile illness. A comprehensive, updatable map of the true distribution of cases has been lacking, and therefore the true risk of disease within the very large endemic area remains unknown. The purpose of this study was to establish a database and map to track human scrub typhus. An online search using PubMed and the United States Armed Forces Pest Management Board Literature Retrieval System was performed to identify articles describing human scrub typhus cases both within and outside the traditionally accepted endemic regions. Using World Health Organization guidelines, stringent criteria were used to establish diagnoses for inclusion in the database. The preliminary screening of 181 scrub typhus publications yielded 145 publications that met the case criterion, 267 case records, and 13 serosurvey records that could be georeferenced, describing 13,739 probable or confirmed human cases in 28 countries. A map service has been established within VectorMap (www.vectormap.org) to explore the role that relative location of vectors, hosts, and the pathogen play in the transmission of mite-borne scrub typhus. The online display of scrub typhus cases in VectorMap illustrates their presence and provides an up-to-date geographic distribution of proven scrub typhus cases.
Successfully Managed Acute Transverse Myelitis Related to Scrub Typhus and Serial Image Findings.
Yun, Jae Sung; Song, Ji Soo; Choi, Eun Jung; Hwang, Jeong-Hwan; Lee, Chang-Seop; Park, Eun Hae
2017-03-01
AbstractCentral nervous system involvement manifesting as meningitis or meningoencephalitis is a known complication of scrub typhus, but very few spinal cord lesions such as acute transverse myelitis (ATM) have been reported in association with this disease. Scrub typhus patients with a spinal lesion present with neurologic symptoms including dysuria, motor, and sensory weakness. Herein, we describe a rare case of ATM associated with scrub typhus. Clinical characteristics, cerebrospinal fluid cytology, Orientia tsutsugamushi serum antibody titer, and serial magnetic resonance imaging scans resulted in a diagnosis of ATM associated with scrub typhus.
Diagnostic validation of selected serological tests for detecting scrub typhus.
Koraluru, Munegowda; Bairy, Indira; Varma, Muralidhar; Vidyasagar, Sudha
2015-07-01
Clinical diagnosis of scrub typhus is often difficult because the symptoms are very similar to those of other febrile illness such as dengue, leptospirosis, malaria and other viral hemorrhagic fevers. Though better diagnostic tests are available for rickettsial diseases and scrub typhus elsewhere, the Weil-Felix test is still commonly used in India, mainly because microimmunofluorescence assays (M-IFA) were not available in India till recently and relevant staff had insufficient training. The present study was performed to investigate the performance of M-IFA, IgM ELISA, and Weil-Felix test on 546 non-repeated serum samples from subjects suspected of having scrub typhus. One hundred and forty-three of these 546 samples were positive by M-IFA; these cases were also confirmed clinically to have scrub typhus based on their dramatic responses to doxycycline therapy. IgM ELISA was positive in 122 of the 143 M-IFA positive cases and the Weil-Felix test in 96. Though the Weil-Felix test is a heterophile agglutination test, it was found in this study to have good specificity but far too little sensitivity to use as a routine diagnostic test. IgM ELISA can be a good substitute for M-IFA. Incorporation of multiple prototype antigens on M-IFA slides is likely one of the reasons for its superior performance. As newer and better diagnostic assays become available for scrub typhus diagnosis in developed countries, it will be imperative to also use such tests in other endemic countries to prevent over- or under-diagnosis of scrub typhus. © 2015 The Societies and Wiley Publishing Asia Pty Ltd.
A Systematic Review of Mortality from Untreated Scrub Typhus (Orientia tsutsugamushi.
Directory of Open Access Journals (Sweden)
Andrew J Taylor
Full Text Available Scrub typhus, a bacterial infection caused by Orientia tsutsugamushi, is increasingly recognized as an important cause of fever in Asia, with an estimated one million infections occurring each year. Limited access to health care and the disease's non-specific symptoms mean that many patients are undiagnosed and untreated, but the mortality from untreated scrub typhus is unknown. This review systematically summarizes the literature on the untreated mortality from scrub typhus and disease outcomes.A literature search was performed to identify patient series containing untreated patients. Patients were included if they were symptomatic and had a clinical or laboratory diagnosis of scrub typhus and excluded if they were treated with antibiotics. The primary outcome was mortality from untreated scrub typhus and secondary outcomes were total days of fever, clinical symptoms, and laboratory results. A total of 76 studies containing 89 patient series and 19,644 patients were included in the final analysis. The median mortality of all patient series was 6.0% with a wide range (min-max of 0-70%. Many studies used clinical diagnosis alone and had incomplete data on secondary outcomes. Mortality varied by location and increased with age and in patients with myocarditis, delirium, pneumonitis, or signs of hemorrhage, but not according to sex or the presence of an eschar or meningitis. Duration of fever was shown to be long (median 14.4 days Range (9-19.Results show that the untreated mortality from scrub typhus appears lower than previously reported estimates. More data are required to clarify mortality according to location and host factors, clinical syndromes including myocarditis and central nervous system disease, and in vulnerable mother-child populations. Increased surveillance and improved access to diagnostic tests are required to accurately estimate the untreated mortality of scrub typhus. This information would facilitate reliable quantification of
A Systematic Review of Mortality from Untreated Scrub Typhus (Orientia tsutsugamushi).
Taylor, Andrew J; Paris, Daniel H; Newton, Paul N
2015-01-01
Scrub typhus, a bacterial infection caused by Orientia tsutsugamushi, is increasingly recognized as an important cause of fever in Asia, with an estimated one million infections occurring each year. Limited access to health care and the disease's non-specific symptoms mean that many patients are undiagnosed and untreated, but the mortality from untreated scrub typhus is unknown. This review systematically summarizes the literature on the untreated mortality from scrub typhus and disease outcomes. A literature search was performed to identify patient series containing untreated patients. Patients were included if they were symptomatic and had a clinical or laboratory diagnosis of scrub typhus and excluded if they were treated with antibiotics. The primary outcome was mortality from untreated scrub typhus and secondary outcomes were total days of fever, clinical symptoms, and laboratory results. A total of 76 studies containing 89 patient series and 19,644 patients were included in the final analysis. The median mortality of all patient series was 6.0% with a wide range (min-max) of 0-70%. Many studies used clinical diagnosis alone and had incomplete data on secondary outcomes. Mortality varied by location and increased with age and in patients with myocarditis, delirium, pneumonitis, or signs of hemorrhage, but not according to sex or the presence of an eschar or meningitis. Duration of fever was shown to be long (median 14.4 days Range (9-19)). Results show that the untreated mortality from scrub typhus appears lower than previously reported estimates. More data are required to clarify mortality according to location and host factors, clinical syndromes including myocarditis and central nervous system disease, and in vulnerable mother-child populations. Increased surveillance and improved access to diagnostic tests are required to accurately estimate the untreated mortality of scrub typhus. This information would facilitate reliable quantification of DALYs and
Directory of Open Access Journals (Sweden)
Thomas R Shelite
2014-07-01
Full Text Available Orientia tsutsugamushi, the etiologic agent of scrub typhus, is a mite-borne rickettsia transmitted by the parasitic larval stage of trombiculid mites. Approximately one-third of the world's population is at risk of infection with Orientia tsutsugamushi, emphasizing its importance in global health. In order to study scrub typhus, Orientia tsutsugamushi Karp strain has been used extensively in mouse studies with various inoculation strategies and little success in inducing disease progression similar to that of human scrub typhus. The objective of this project was to develop a disease model with pathology and target cells similar to those of severe human scrub typhus. This study reports an intravenous infection model of scrub typhus in C57BL/6 mice. This mouse strain was susceptible to intravenous challenge, and lethal infection occurred after intravenous inoculation of 1.25 × 10(6 focus (FFU forming units. Signs of illness in lethally infected mice appeared on day 6 with death occurring ∼ 6 days later. Immunohistochemical staining for Orientia antigens demonstrated extensive endothelial infection, most notably in the lungs and brain. Histopathological analysis revealed cerebral perivascular, lymphohistiocytic infiltrates, focal hemorrhages, meningoencephalitis, and interstitial pneumonia. Disseminated infection of endothelial cells with Orientia in C57BL/6 mice resulted in pathology resembling that of human scrub typhus. The use of this model will allow detailed characterization of the mechanisms of immunity to and pathogenesis of O. tsutsugamushi infection.
Valappil, Ashraf V; Thiruvoth, Sohanlal; Peedikayil, Jabir M; Raghunath, Praveenkumar; Thekkedath, Manojan
2017-12-01
The involvement of the central nervous system in the form of meningitis or meningoencephalitis is common in scrub typhus and is an important differential diagnosis of other lymphocytic meningitis like tuberculous meningitis (TBM). The aim of this study was to identify the clinical and laboratory parameters that may be helpful in differentiating scrub typhus meningitis from TBM. We compared of the clinical and laboratory features of 57 patients admitted with scrub typhus meningitis or TBM during a 3-year period. Patients who had abnormal cerebrospinal fluid (CSF) and positive scrub typhus enzyme-linked immunosorbent assay serology (n=28) were included in the scrub typhus meningitis group, while the TBM group included those who satisfied the consensus diagnostic criteria of TBM (n=29). Compared with the TBM group, the mean duration of symptoms was less in patients with scrub typhus meningitis, who also had a lower magnitude of neurological deficits, such as altered mental status and cranial nerve and motor deficits. Patients with scrub typhus meningitis had a lower CSF white blood-cell count (WBC) than the TBM group (130.8±213 195±175 cells/mm 3 , P=0.002), lower CSF protein elevation (125±120 vs. 195.2±108.2mg/dl, P=0.002), and higher CSF sugar (70.1±32.4 vs. 48.7±23.4mg/dl, P=0.006). Features predictive of the diagnosis of scrub typhus meningitis included the absence of neurological impairment at presentation, blood serum glutamic-oxaloacetic transaminase>40 international units (IU)/L, serum glutamic-pyruvic transaminase>60 IU/L, total blood leukocyte count>10,000/mm 3 , CSF protein50mg/dl, CSF WBC<100 cells/mm 3 . All patients with scrub typhus meningitis recovered completely following doxycycline therapy CONCLUSIONS: This study suggests that, clinical features, including duration of fever, neurological deficits at presentation and laboratory parameters such as CSF pleocytosis,CSF protein elevation, CSF sugar levels and liver enzyme values are helpful in
Meteorological factors and risk of scrub typhus in Guangzhou, southern China, 2006–2012
2014-01-01
Background Scrub typhus is becoming the most common vector born disease in Guangzhou, southern China. In this study, we aimed to examine the effect of weather patterns on the incidence of Scrub typhus in the subtropical city of Guangzhou for the period 2006–2012, and assist public health prevention and control measures. Methods Scrub typhus reported cases during the period of 2006–2012 in Guangzhou were obtained from National Notifiable Disease Report System (NNDRS). Simultaneous meteorological data including temperature, relative humidity, atmospheric pressure, sunshine, and rainfall were obtained from the documentation of the Guangzhou Meteorological Bureau. A negative binomial regression was used to identify the relationship between meteorological variables and scrub typhus. Results Annual incidence rates of scrub typhus from 2006 to 2012 were 3.25, 2.67, 3.81, 4.22, 4.41, 5.12, and 9.75 (per 100 000) respectively. Each 1°C rise in temperature corresponded to an increase of 14.98% (95% CI 13.65% to 16.33%) in the monthly number of scrub typhus cases, while a 1 hPa rise in atmospheric pressure corresponded to a decrease in the number of cases by 8.03% (95% CI −8.75% to −7.31%). Similarly, a 1 hour rise in sunshine corresponded to an increase of 0.17% or 0.54%, and a 1 millimeter rise in rainfall corresponded to an increase of 0.05% or 0.10%, in the monthly number of scrub typhus cases, depending on the variables considered in the model. Conclusion Our study provided evidence that climatic factors were associated with occurrence of scrub typhus in Guangzhou city, China. Temperature, duration of sunshine, and rainfall were positively associated with scrub typhus incidence, while atmospheric pressure was inversely associated with scrub typhus incidence. These findings should be considered in the prediction of future patterns of scrub typhus transmission. PMID:24620733
Rizvi, Meher; Sultan, Asfia; Chowdhry, Madhav; Azam, Mohd; Khan, Fatima; Shukla, Indu; Khan, Haris M
2018-01-01
Scrub typhus is lesser known cause of fever of unknown origin in India. Even if there have been reports documenting the prevalence of scrub typhus in different parts of India, it is still an unknown entity, and clinicians usually do not consider it as differential diagnosis. The present study was performed to document the prevalence of scrub typhus among febrile patients in western part of Uttar Pradesh and to assess the clinical profile of infected patients on the one hand and knowledge, attitude, and practices among clinicians on the other. A total of 357 adult patients with fever of more than 5-day duration were recruited. All patients underwent complete physical examination, and detailed clinical history was elicited as per predesigned pro forma. After primary screening to rule out malaria, enteric fever, and leptospirosis infection, secondary screening for scrub typhus was done by rapid screen test and IgM ELISA. Scrub typhus infection was positive in 91 (25.5%) cases. The most common symptoms among the patients were fever (100%), pain in abdomen (79.1%), pedal edema 56 (61.5%), rash 44 (48.3%), headache 44 (48.3%), vomiting 42 (46.1%), constipation 33 (36.2%), cough 28 (30.7%), and lymphadenopathy 20 (21.9%). The median values of interleukin-8, interferon-gamma, and tumor necrosis factor-alpha in healthy controls were 15.54 pg/ml, 7.77 pg/ml, and 54.1 pg/ml, respectively, while the median values of these cytokines in scrub typhus-positive patients were 21.04 pg/ml, 8.74 pg/ml, and 73.8 pg/ml, respectively. Our results highlight that scrub typhus infection is an important cause of pyrexia of unknown origin, and active surveillance is necessary to assess the exact magnitude and distribution of the disease.
[Epidemiology of scrub typhus and influencing factors in Yunnan province, 2006-2013].
Sun, Y; Shi, C; Li, X L; Fang, L Q; Cao, W C
2018-01-10
Objective: To understand the epidemiological characteristics of scrub typhu s and influencing factors in Yunnan province, and provide further information for the prevention and control of scrub typhus. Methods: Based on the incidence data of scrub typhus reported in Yunnan from 2006 to 2013, the epidemiological characteristics of scrub typhus were analyzed and related environmental factors were identified with panel negative binomial regression model. Results: A total of 8 980 scrub typhus cases were reported during 2006-2013 in Yunnan. The average annual incidence was 2.46/100 000, with an uptrend observed. Natural focus expansion was found, affecting 71.3% of the counties in 2013. The epidemic mainly occurred in summer and autumn with the incidence peak during July-October. The annual incidence was higher in females than in males. More cases occurred in children and farmers, the proportions of cases in farmers and pre-school aged children showed an obvious increase. Panel negative binomial regression model indicated that the transmission risk of scrub typhus was positive associated with monthly temperature and monthly relative humidity. Furthermore, an "U" pattern between the risk and the increased coverage of cropland and grassland as well as an "inverted-U" pattern between the risk and increased coverage of shrub were observed. Conclusion: It is necessary to strengthen the scrub typhus surveillance in warm and moist areas as well as the areas with high coverage of cropland and grassland in Yunnan, and the health education in children and farmers who are at high risk.
Management of Florida Scrub for Threatened and Endangered Species
1998-12-01
for Florida scrub: 1. The exotic species, cogon grass ( Imperata cylindrica), may become common in degraded scrubs. This is an aggressive, invasive...34Cogongrass, Imperata cylindrica (L.) Beauv.: A good grass gone bad!" Botany Circular No. 28, Florida Dept. Agric. & Consumer Services, Division of Plant...Industry, Gainesville, FL. Colvin, D.L., Gaffney, J., and Shilling, D. G. 1994. "Cogongrass ( Imperata cylindrica (L.) Beauv.) Biology, ecology and
Iodine Gas Trapping using Granular Porous Bismuth
Energy Technology Data Exchange (ETDEWEB)
Yang, Jae Hwan; Shin, Jin Myeong; Park, Jang Jin; Park, Geun Il [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yim, Mansung [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)
2014-05-15
{sup 129}I is a radionuclide with a very long half-life of 1.57 Χ 10{sup 7} years and has negative health effects to the human body. Therefore, the emission of {sup 129}I into the air is closely regulated by the Environmental Protection Agency (EPA). Many methods for trapping gaseous {sup 129}I have been developed thus far, including wet scrubbing and adsorption using silver loaded zeolites. Although wet scrubbing can effectively remove iodine, it suffers from corrosion of the vessel due to high concentration of the scrubbing solution. Silver loaded zeolites also show effectiveness in capturing {sup 129}I gas, yet weak thermal stability of physisorbed iodine remains a challenge. We studied a novel and facile method to trap iodine gas using bismuth. Granular bismuth having many pores was synthesized using bismuth nitrate and polyvinyl alcohol as a bismuth precursor and pore forming agent, respectively. Reaction of iodine and our samples resulted in an iodine capturing capacity of more than 2 times that of the commercial grade silver exchanged zeolite (AgX). Granular porous bismuths synthesized using bismuth nitrate and PVA show a promising performance in capturing iodine gas. The use of bismuth in trapping {sup 129}I gas can reduce the process cost as bismuth is cheap. Further study is going on to improve the mechanical property of granular porous bismuths for their easy handling.
Iodine Gas Trapping using Granular Porous Bismuth
International Nuclear Information System (INIS)
Yang, Jae Hwan; Shin, Jin Myeong; Park, Jang Jin; Park, Geun Il; Yim, Mansung
2014-01-01
129 I is a radionuclide with a very long half-life of 1.57 Χ 10 7 years and has negative health effects to the human body. Therefore, the emission of 129 I into the air is closely regulated by the Environmental Protection Agency (EPA). Many methods for trapping gaseous 129 I have been developed thus far, including wet scrubbing and adsorption using silver loaded zeolites. Although wet scrubbing can effectively remove iodine, it suffers from corrosion of the vessel due to high concentration of the scrubbing solution. Silver loaded zeolites also show effectiveness in capturing 129 I gas, yet weak thermal stability of physisorbed iodine remains a challenge. We studied a novel and facile method to trap iodine gas using bismuth. Granular bismuth having many pores was synthesized using bismuth nitrate and polyvinyl alcohol as a bismuth precursor and pore forming agent, respectively. Reaction of iodine and our samples resulted in an iodine capturing capacity of more than 2 times that of the commercial grade silver exchanged zeolite (AgX). Granular porous bismuths synthesized using bismuth nitrate and PVA show a promising performance in capturing iodine gas. The use of bismuth in trapping 129 I gas can reduce the process cost as bismuth is cheap. Further study is going on to improve the mechanical property of granular porous bismuths for their easy handling
Thermodynamic modelling of acid gas removal from natural gas using the Extended UNIQUAC model
DEFF Research Database (Denmark)
Sadegh, Negar; Stenby, Erling Halfdan; Thomsen, Kaj
2017-01-01
Thermodynamics of natural gas sweetening process needs to be known for proper design of natural gas treating plants. Absorption with aqueous N-Methyldiethanolamine is currently the most commonly used process for removal of acid gas (CO2 and H2S) impurities from natural gas. Model parameters...... for the Extended UNIQUAC model have already been determined by the same authors to calculate single acid gas solubility in aqueous MDEA. In this study, the model is further extended to estimate solubility of CO2 and H2S and their mixture in aqueous MDEA at high pressures with methane as a makeup gas....
Factors that influence the non-technical skills performance of scrub nurses: a prospective study.
Kang, Evelyn; Massey, Debbie; Gillespie, Brigid M
2015-12-01
To identify and describe the factors that impact on the performance of scrub nurses' non-technical skills performance during the intra-operative phase of surgery. Non-technical skills have been identified as important precursors to errors in the operating room. However, few studies have investigated factors influencing non-technical skills of scrub nurses. Prospective observational study. Structured observations were performed on a sample of 182 surgical procedures across eight specialities by two trained observers from August 2012-April 2013 at two hospital sites. Participants were purposively selected scrub nurses. Bivariate correlations and a multiple linear regression model were used to identify associations among length of surgery, patients' acuity using the American Society of Anesthesiologists classification system, team familiarity, number of occasions scout nurses leave the operating room, change of scout nurse and the outcome, the non-technical skills performance of scrub nurses. Patient acuity and team familiarity were the strongest predictors of scrub nurses' non-technical skills performance at hospital site A. There were no correlations between the predictors and the performance of scrub nurses at hospital site B. A dedicated surgical team and patient acuity potentially influence the performance of scrub nurses' non-technical skills. Familiarity with team members foster advanced planning, thus minimizing distractions and interruptions that impact on scrub nurses' performance. Development of interventions aimed at improving non-technical skills has the potential to make a substantial difference and enhance patient care. © 2015 John Wiley & Sons Ltd.
International Nuclear Information System (INIS)
Timpson, M.E.; Elless, M.P.; Francis, C.W.
1994-01-01
As part of the Uranium in Soils Integrated Demonstration Project being conducted by the US Department of Energy, bench-scale investigations of selective leaching of uranium from soils at the Fernald Environmental Management Project site in Ohio were conducted at Oak Ridge National Laboratory. Two soils (storage pad soil and incinerator soil), representing the major contaminant sources at the site, were extracted using carbonate- and citric acid-based lixiviants. Physical and chemical processes were used in combination with the two extractants to increase the rate of uranium release from these soils. Attrition scrubbing and ultrasonic dispersion were the two physical processes utilized. Potassium permanganate was used as an oxidizing agent to transform tetravalent uranium to the hexavalent state. Hexavalent uranium is easily complexed in solution by the carbonate radical. Attrition scrubbing increased the rate of uranium release from both soils when compared with rotary shaking. At equivalent extraction times and solids loadings, however, attrition scrubbing proved effective only on the incinerator soil. Ultrasonic treatments on the incinerator soil removed 71% of the uranium contamination in a single extraction. Multiple extractions of the same sample removed up to 90% of the uranium. Additions of potassium permanganate to the carbonate extractant resulted in significant changes in the extractability of uranium from the incinerator soil but had no effect on the storage pad soil
Stover, Michele L; Jackson, Virgil E; Matus, Myrna H; Adams, Margaret A; Cassady, Carolyn J; Dixon, David A
2012-03-08
The gas-phase acidities of the 20 L-amino acids have been predicted at the composite G3(MP2) level. A broad range of structures of the neutral and anion were studied to determine the lowest energy conformer. Excellent agreement is found with the available experimental gas-phase deprotonation enthalpies, and the calculated values are within experimental error. We predict that tyrosine is deprotonated at the CO(2)H site. Cysteine is predicted to be deprotonated at the SH but the proton on the CO(2)H is shared with the S(-) site. Self-consistent reaction field (SCRF) calculations with the COSMO parametrization were used to predict the pK(a)'s of the non-zwitterion form in aqueous solution. The differences in the non-zwitterion pK(a) values were used to estimate the free energy difference between the zwitterion and nonzwitterion forms in solution. The heats of formation of the neutral compounds were calculated from atomization energies and isodesmic reactions to provide the first reliable set of these values in the gas phase. Further calculations were performed on five rare amino acids to predict their heats of formation, acidities, and pK(a) values.
Recovery of actinides from TBP-Na2Co3 scrub-waste solutions: the ARALEX process
International Nuclear Information System (INIS)
Horwitz, E.P.; Bloomquist, C.A.A.; Mason, G.W.; Leonard, R.A.; Ziegler, A.A.
1979-08-01
A flowsheet for the recovery of actinides from TBP-Na 2 CO 3 scrub-waste solutions has been developed, based on batch extraction data, and tested, using laboratory-scale countercurrent extraction techniques. The process, called the ARALEX process, uses 2-ethyl-1-hexanol (2-EHOH) to extract the TBP degradation products (HDBP and H 2 MBP) from acidified Na 2 CO 3 scrub waste leaving the actinides in the aqueous phase. Dibutyl and monobutyl phosphoric acids are attached to the 2-EHOH molecules through hydrogen bonds, which also diminish the ability of the HDBP and H 2 MBP to complex actinides. Thus all actinides remain in the aqueous raffinate. Dilute sodium hydroxide solutions can be used to back-extract the dibutyl and monobutyl phosphoric acid esters as their sodium salts. The 2-EHOH can then be recycled. After extraction of the acidified carbonate waste with 2-EHOH, the actinides may be readily extracted from the raffinate with DHDECMP or, in the case of tetra- and hexavalent actinides, with TBP. The ARALEX process can also be applied to other actinide waste streams which contain appreciable concentrations of polar organic compounds (e.g., detergents) that interfere with conventional actinide ion exchange and liquid-liquid extraction procedures. 20 figures, 6 tables
Risk factors associated with severe scrub typhus in Shandong, northern China
Directory of Open Access Journals (Sweden)
Luyan Zhang
2014-12-01
Conclusions: This study indicates that improved diagnosis and timely treatment are important factors for the prevention of severe scrub typhus. When scrub typhus patients present with a rash, lymphadenopathy, or blood platelet count <100 × 109/l, clinicians should be alert to the appearance of severe complications.
Scrub-shrub bird habitat associations at multiple spatial scales in beaver meadows in Massachusetts
Chandler, R.B.; King, D.I.; DeStefano, S.
2009-01-01
Most scrub-shrub bird species are declining in the northeastern United States, and these declines are largely attributed to regional declines in habitat availability. American Beaver (Castor canadensis; hereafter “beaver”) populations have been increasing in the Northeast in recent decades, and beavers create scrub-shrub habitat through their dam-building and foraging activities. Few systematic studies have been conducted on the value of beaver-modified habitats for scrub-shrub birds, and these data are important for understanding habitat selection of scrub-shrub birds as well as for assessing regional habitat availability for these species. We conducted surveys in 37 beaver meadows in a 2,800-km2 study area in western Massachusetts during 2005 and 2006 to determine the extent to which these beaver-modified habitats are used by scrub-shrub birds, as well as the characteristics of beaver meadows most closely related to bird use. We modeled bird abundance in relation to microhabitat-, patch-, and landscape-context variables while adjusting for survey-specific covariates affecting detectability using N-mixture models. We found that scrub-shrub birds of regional conservation concern occupied these sites and that birds responded differently to microhabitat, patch, and landscape characteristics of beaver meadows. Generally, scrub-shrub birds increased in abundance along a gradient of increasing vegetation complexity, and three species were positively related to patch size. We conclude that these habitats can potentially play an important role in regional conservation of scrub-shrub birds and recommend that conservation priority be given to larger beaver meadows with diverse vegetation structure and composition.
Sharma, S R; Masaraf, H; Lynrah, K G; Lyngdoh, M
2015-01-01
Scrub typhus is rampant in northern, eastern, and southern India. Central nervous system involvement in the form of meningitis or meningoencephalitis is common in scrub typhus. As specific laboratory methods remain inadequate or inaccessible in developing countries, prompt diagnosis is often difficult. The aim of this study was to characterize neurological complications in scrub typhus from northeastern region of India. We did a prospective study of scrub meningoencephalitis at North Eastern Indira Gandhi Regional Institute of Medical Sciences among patients admitted to hospital between October 2009 and November 2011. The diagnosis was made based on the clinical pictures, presence of an eschar, and a positive Weil-Felix test (WFT) with a titer of >1:160 and if required a positive scrub IgM enzyme-linked immunosorbent assay. Lumbar puncture was performed in patients with headache, nuchal rigidity, altered sensorium or cranial nerve deficits, and magnetic resonance imaging (MRI) brain performed if needed. Twenty-three patients of scrub typhus meningitis that were serologically confirmed were included in the study. There were 13 males and 10 females. Fever ≥1 week was the most common manifestation (39.1%). Interestingly, none had an eschar. Median cerebrospinal fluid (CSF) cell count, lymphocyte percentage, CSF protein, CSF glucose/blood glucose, CSF ADA were 17 cells/μL, 90%, 86 mg/dL, 0.6605 and 3.6 U/mL, respectively. All patients were treated with doxycycline. There was no mortality in our study. Absence of Eschar does not rule out scrub typhus. Clinical features and CSF findings can mimic tuberculous meningitis so misdiagnosis may lead to unwarranted prolonged empirical antituberculous therapy in cases of lymphocytic meningoencephalitis. Delay in treatment can be potentially fatal. WFT still serves as a useful and affordable diagnostic tool for this disease in resource-poor countries.
Adaptation of a tool to assess non-technical skills of scrub practitioners in Denmark.
Mundt, Anna Sofie; Spanager, Lene; Lyk-Jensen, Helle Teglgaard; Østergaard, Doris
2017-09-01
The aim of this study was to adapt the Scottish tool, Scrub Practitioners List of Intraoperative Non-Technical Skills, to Danish organisation and culture. With an explorative and qualitative approach, four group interviews with scrub practitioners, surgeons and anaesthesia staff were conducted. The main differences found were related to communication and teamwork regarding scrub practitioners focus on the team and speaking up. Differences in the non-technical skills described in the behavioural markers are perhaps explained by cultural differences between Scotland and Denmark. A new tool for scrub practitioners in Denmark was adapted. Copyright the Association for Perioperative Practice.
Bilateral Symmetrical Brachial Plexopathy in Association with Scrub Typhus: A Rare Presentation
Directory of Open Access Journals (Sweden)
Mittal M
2015-10-01
Full Text Available Scrub typhus is a commonly encountered rickettsial disease of the Indian subcontinent caused by Orientia tsutsugamushi. It can be associated with various neurological manifestations. We report a case of 50 year old man with bilateral symmetrical brachial plexopathy associated with scrub typhus from the Garhwal region of Uttarakhand state. The initial manifestations were fever, bodyaches and weakness in both upper limbs. Laboratory reports confirmed the diagnosis of scrub typhus. EMG and NCV were strongly suggestive of upper brachial plexopathy. Patient was discharged in satisfactory condition
Scrub typhus re-emergence in India: Contributing factors and way forward.
Ranjan, Jai; Prakash, John Antony Jude
2018-06-01
Scrub typhus is a mite borne infectious disease which has re-emerged in India in the 3rd millennium after years of quiescence. In this review, the authors hypothesize the various factors responsible for resurgence of this disease. The main drivers that could have contributed to the upsurge in scrub typhus cases in past two decades are changes in land use land cover (LULC) and urbanisation which are; as a result of the population explosion, causing a strain on sanitation and also increased diversion of forest land for agricultural use. In addition, the availability of better tests, changes in antimicrobial use, climate change also could have impacted the epidemiology, which is showing an upward trend as is evidenced by increasing reports and concomitant publications from India on scrub typhus. Scrub typhus cases are supposed to increase in the coming years as factors like global warming, urbanisation, changes in LULC and rise in AMR (anti-microbial resistance) will be difficult or impossible to control. Therefore, increasing awareness of public and health care professionals regarding scrub typhus coupled with availability of rapid diagnostic assays and implementation of appropriate treatment protocols for control of AFI (acute febrile illness) especially at the community level will help mitigate the scenario in the long run. Copyright © 2018. Published by Elsevier Ltd.
Acute transverse myelitis following scrub typhus: A case report and review of the literature.
Ryu, Hyun-Seung; Moon, Bong Ju; Park, Jae-Young; Kim, Sang-Deok; Seo, Seung-Kwon; Lee, Jung-Kil
2018-01-19
Context Scrub typhus is an acute febrile disease caused by Orientia tsutsugamushi. The disease can usually involve the lungs, heart, liver, spleen and brain through hematogenous dissemination. However, very rarely, acute transverse myelitis in the spinal cord develops from scrub typhus. We present a case of acute transverse myelitis following scrub typhus with a review of the literature. Findings A 66-year-old male visited a hospital for general myalgia, mild headache, and fever in October. He was noted to have thick, black papule skin on his abdomen, which was highly suggestive of scrub typhus. To confirm the diagnosis, O. tsutsugamushi antibody titers were examined and detected highly in serum by an indirect fluorescence antibody assay. Doxycycline, the standard treatment for scrub typhus, was administered. However, after seven days of treatment, he rapidly developed weakness in the right leg, paresthesia in both lower limbs, and voiding difficulty. Spinal magnetic resonance imaging (MRI) revealed lesions with high signal intensity involving the spinal cord at the thoracolumbar junction. Paraparesis gradually improved following steroid pulse therapy for five days. At one-year follow-up, he could walk without cane. Conclusions Orientia tsutsugamushi causes scrub typhus, which can affect not only the brain, but also the spinal cord. Although acute transverse myelitis develops rarely from scrub typhus, this should be considered as differential diagnosis in patients of fever with neurological deficit in endemic areas.
Using Willie's Acid-Base Box for Blood Gas Analysis
Dietz, John R.
2011-01-01
In this article, the author describes a method developed by Dr. William T. Lipscomb for teaching blood gas analysis of acid-base status and provides three examples using Willie's acid-base box. Willie's acid-base box is constructed using three of the parameters of standard arterial blood gas analysis: (1) pH; (2) bicarbonate; and (3) CO[subscript…
Redhead, John; Cuevas-Gonzales, Maria; Smith, Geoffrey; Gerard, France; Pywell, Richard
2012-04-30
Controlling scrub encroachment is a major challenge for conservation management on chalk grasslands. However, direct comparisons of scrub removal methods have seldom been investigated, particularly at the landscape scale. Effective monitoring of grassland scrub is problematic as it requires simultaneous information on large scale patterns in scrub cover and fine-scale changes in the grassland community. This study addressed this by combining analysis of aerial imagery with rapid field surveys in order to compare the effectiveness of four scrub management strategies on Defence Training Estate Salisbury Plain, UK. Study plots were sited within areas undergoing management and in unmanaged controls. Controls showed dramatic increases in scrub cover, with encroachment of a mean 1096 m(2) per hectare over ten years. Whilst all management strategies were effective in reducing scrub encroachment, they differed in their ability to influence regeneration of scrub and grassland quality. There was a general trend, evident in both the floral community and scrub levels, of increased effectiveness with increasing management intensity. The dual methodology proved highly effective, allowing rapid collection of data over a range of variables and spatial scales unavailable to each method individually. The methodology thus demonstrates potential for a useful monitoring tool. Copyright © 2011 Elsevier Ltd. All rights reserved.
Krischan, J; Makaruk, A; Harasek, M
2012-05-15
Reliable and selective removal of hydrogen sulfide (H(2)S) is an essential part of the biogas upgrading procedure in order to obtain a marketable and competitive natural gas substitute for flexible utilization. A promising biogas desulfurization technology has to ensure high separation efficiency regardless of process conditions or H(2)S load without the use or production of toxic or ecologically harmful substances. Alkaline oxidative scrubbing is an interesting alternative to existing desulfurization technologies and is investigated in this work. In experiments on a stirred tank reactor and a continuous scrubbing column in laboratory-scale, H(2)S was absorbed from a gas stream containing large amounts of carbon dioxide (CO(2)) into an aqueous solution prepared from sodium hydroxide (NaOH), sodium bicarbonate (NaHCO(3)) and hydrogen peroxide (H(2)O(2)). The influence of pH, redox potential and solution aging on the absorption efficiency and the consumption of chemicals was investigated. Because of the irreversible oxidation reactions of dissolved H(2)S with H(2)O(2), high H(2)S removal efficiencies were achieved while the CO(2) absorption was kept low. At an existing biogas upgrading plant an industrial-scale pilot scrubber was constructed, which efficiently desulfurizes 180m(3)/h of raw biogas with an average removal efficiency of 97%, even at relatively high and strongly fluctuating H(2)S contents in the crude gas. Copyright © 2012 Elsevier B.V. All rights reserved.
STATUS OF SCRUB TYPHUS RESEARCH IN INDONESIA (Based on published reports
Directory of Open Access Journals (Sweden)
Lim Boo Liat
2012-09-01
Full Text Available Scrub typhus merupakan penyakit yang endemis di Indonesia. Akan tetapi laporan mengenai hal tersebut sangat sedikit. Penelusuran hasil penelitian menunjukkan bahwa sebelum tahun 1945 pernah dilaporkan hasil isolasi Rickettsia tsutsugamushi dari penderita demam di beberapa tempat di Indonesia. Setelah tahun 1970 beberapa penelitian seroepidemiologi dilakukan di beberapa daerah di Indonesia terutama daerah transmigrasi dengan hasil prevalensi antibodi terhadap scrub typhus tertinggi di daerah Biak dan Owi, Irian Jaya dan yang terendah di Flores dan Jakarta. Selain itu dilakukan pula penelitian mengenai vektor scrub typhus dan hospesnya dengan hasil ditemukannya 7 species tungau Leptotrombidium termasuk 2 jenis yang merupakan vektor. Saran untuk penelitian di masa yang akan datang diberikan dalam laporan ini.
Energy Technology Data Exchange (ETDEWEB)
Polo, J; Herranz, L E; Peyres, V; Escudero, M [CIEMAT, Nuclear Technology Institute, Madrid (Spain)
1996-12-01
During a hypothetical nuclear reactor accident with core damage the fission products released from the degrading fuel bundles often pass through aqueous beds before entering the containment, mitigating in part the source term. Several computer codes have been developed for predicting the fission product and aerosols removal in pool scrubbing scenarios. In addition to particle removal, these codes simulate the retention of some volatile iodine compounds. In this work a review of volatile iodine removal models included in SPARC and BUSCA codes is presented. Besides, the results and discussions of a validation of both codes against the available experimental data are summarized. SPARC and BUSCA codes model the diffusion of iodine toward the bubble interface by using the film penetration theory, which assumes a double layer gas-liquid at the interface. However, there are some differences between the two models, mainly related to the boundary conditions in the aqueous volume for the diffusion of molecular iodine. In SPARC, a set of fast reactions in the liquid phase control both the molecular iodine concentration in the pool and the partition coefficient of iodine at the interface. Thus, the aqueous chemistry plays an important role in the boundary conditions for the diffusion process. On the contrary, the BUSCA model has no chemical considerations at all, and assumes a null iodine concentration in the water bulk. Several sensitivity studies have been made in order to weight the effect of these differences. The variables examined in these studies were the pool temperature and the incoming iodine concentration in the pool. Additionally, sensitivity studies focused on the steam mass fraction of the injected gas were performed to study the effect of the different approach of both models for the condensation process. The results showed a different sensitivity of SPARC and BUSCA to the incoming concentration. (author) 5 tabs., 26 refs.
Energy Technology Data Exchange (ETDEWEB)
Fukunaga, A. [Ebara Research Co. Ltd., Kanagawa (Japan); Mori, Y.; Osato, M.; Tsujimura, M. [Ebara Corp., Tokyo (Japan)
1995-10-20
Demand has been building up for an individual dry type scrubber for treating exhaust gas from the semiconductor manufacturing process. Some factors for the wide acceptance of such a scrubber would be the capability for complete treatment, easy maintenance and safety features, etc. Practical gas analysis and optimum scrubbing techniques would have to be applied, as well as effective monitoring, alarm, and fail-safe techniques. The overall exhaust gas line, i.e. the line connecting the scrubber system and the upstream process, including that extending to pump system, has to be fully considered for enabling effective scrubbing performance. Such factors, which have until now not been given any priority, would have to be fully studied for the development of a practical, individual dry type scrubber. Cooperation on this matter from the semiconductor manufacturing industry would also be essential. 6 refs., 3 figs., 5 tabs.
Prevalence and risk factors for scrub typhus in South India.
Trowbridge, Paul; P, Divya; Premkumar, Prasanna S; Varghese, George M
2017-05-01
To determine the prevalence and risk factors of scrub typhus in Tamil Nadu, South India. We performed a clustered seroprevalence study of the areas around Vellore. All participants completed a risk factor survey, with seropositive and seronegative participants acting as cases and controls, respectively, in a risk factor analysis. After univariate analysis, variables found to be significant underwent multivariate analysis. Of 721 people participating in this study, 31.8% tested seropositive. By univariate analysis, after accounting for clustering, having a house that was clustered with other houses, having a fewer rooms in a house, having fewer people living in a household, defecating outside, female sex, age >60 years, shorter height, lower weight, smaller body mass index and smaller mid-upper arm circumference were found to be significantly associated with seropositivity. After multivariate regression modelling, living in a house clustered with other houses, female sex and age >60 years were significantly associated with scrub typhus exposure. Overall, scrub typhus is much more common than previously thought. Previously described individual environmental and habitual risk factors seem to have less importance in South India, perhaps because of the overall scrub typhus-conducive nature of the environment in this region. © 2017 John Wiley & Sons Ltd.
Energy Technology Data Exchange (ETDEWEB)
Heo, Young Jin; Jeong, Hae Woong [Dept. of Radiology, Inje University Busan Paik Hospital, Busan (Korea, Republic of)
2015-11-15
Scrub typhus is a well-known acute febrile illness caused by Orientia tsutsugamushi. This disease has multiorgan involvement, which includes the lungs, heart, liver, spleen, and the central or peripheral nervous system. Scrub typhus involving the central nervous system (CNS) is not rare. However, meningitis and meningoencephalitis can cause changes in mentation and death and are therefore associated with a poor prognosis. We report two consecutive cases of scrub typhus with CNS involvement. One patient presented with extensive white matter involvement, similar to that observed in acute disseminated encephalomyelitis, whereas the other patient presented with subependymal enhancement along the lateral ventricles. To the best of our knowledge, scrub typhus encephalitis, with extensive white matter involvement and subependymal enhancement, are very rarely described findings in the previous literature. Our patients did not show complete recovery, but the symptoms resolved with treatment. Recognizing these uncommon radiologic findings of scrub typhus may be helpful in the early diagnosis of scrub typhus with CNS involvement, which may alter the prognoses of patients.
International Nuclear Information System (INIS)
Heo, Young Jin; Jeong, Hae Woong
2015-01-01
Scrub typhus is a well-known acute febrile illness caused by Orientia tsutsugamushi. This disease has multiorgan involvement, which includes the lungs, heart, liver, spleen, and the central or peripheral nervous system. Scrub typhus involving the central nervous system (CNS) is not rare. However, meningitis and meningoencephalitis can cause changes in mentation and death and are therefore associated with a poor prognosis. We report two consecutive cases of scrub typhus with CNS involvement. One patient presented with extensive white matter involvement, similar to that observed in acute disseminated encephalomyelitis, whereas the other patient presented with subependymal enhancement along the lateral ventricles. To the best of our knowledge, scrub typhus encephalitis, with extensive white matter involvement and subependymal enhancement, are very rarely described findings in the previous literature. Our patients did not show complete recovery, but the symptoms resolved with treatment. Recognizing these uncommon radiologic findings of scrub typhus may be helpful in the early diagnosis of scrub typhus with CNS involvement, which may alter the prognoses of patients
Tsutsugamushi Disease (Scrub Typhus) Meningoencephalitis in ...
African Journals Online (AJOL)
Conclusions: Absence of Eschar does not rule out scrub typhus. Clinical features and CSF findings can mimic tuberculous meningitis so misdiagnosis may lead to unwarranted prolonged empirical antituberculous therapy in cases of lymphocytic meningoencephalitis. Delay in treatment can be potentially fatal. WFT still ...
Scrub typhus in rural Rajasthan and a review of other Indian studies.
Masand, Rupesh; Yadav, Ritesh; Purohit, Alok; Tomar, Balvir Singh
2016-05-01
Scrub typhus is an acute febrile illness which has been reported from various parts of India with Rajasthan recently joining the list of affected states. To report a series of paediatric scrub typhus cases from rural Rajasthan. Retrospective review of children with scrub typhus admitted to the wards and paediatric intensive care unit (PICU) of a tertiary-care hospital. The study was undertaken over an 8-month period from May to December 2013. All patients with a clinical presentation and/or serological confirmation of scrub typhus who tested negative for malaria, enteric fever, dengue, leptospirosis and urinary tract infection (UTI) were included. A range of investigations were undertaken including IgM-ELISA for scrub typhus, followed by appropriate medical management. Thirty patients satisfied the inclusion criteria. The mean (SD, range) age of the patients was 8·56 (3·43, 3-16) years. The most common clinical features were fever (n = 30, 100%), headache (n = 20, 66%), myalgia (n = 15, 50%), hepatosplenomegaly (n = 18, 60%) and pallor (n = 5, 16%). Typical features such as eschar and rash were observed in only one (3·3%) and three (10%) patients, respectively; none had generalised lymphadenopathy or conjunctival congestion. IgM-ELISA for scrub typhus was positive in 28 patients (93·3%) and 27 responded to doxycycline within 24-72 hours. One of the three patients who required PICU support responded to intravenous chloramphenicol and, of the other two (6·6%), one died of acute respiratory distress syndrome and the other owing to acute renal failure. A high index of suspicion is essential for early diagnosis and prevention of complications in scrub typhus together with prompt referral from rural areas to a higher centre. Awareness of the disease manifestations may further help to prevent excessive investigations in patients presenting with non-specific febrile illness and reduce the economic burden to the family and society in resource
Off-gas considerations for a vitrification plant in the republic of Korea
International Nuclear Information System (INIS)
Chun, Ung Kyung; Park, Jong Kil; Yang, Kyung Hwa; Song, Myung Jae
1997-01-01
of incomplete combustion (PICs), particle scrubbing, acid gas scrubbing, particle filtering, and continuous emissions monitoring that would also be utilized for other thermal treatment systems such as incinerators. Although, it is still not possible to use only computer simulation for the design of an off-gas treatment system, numerical modelling may be utilized to help speed design, examine situations difficult to model experimentally, help optimize system processes, etc. These considerations should help provide for an optimal off-gas treatment system for the managing of toxic emissions
Epidemiology & risk factors of scrub typhus in south India
Directory of Open Access Journals (Sweden)
George M Varghese
2016-01-01
Full Text Available Background & objectives: Scrub typhus is a major public health threat in South and Southeastern Asian countries including India. Understanding local patterns of disease and factors that place individuals at risk is pivotal to future preventive measures against scrub typhus. The primary aim of this study was to identify specific epidemiological and geographical factors associated with an increased risk of developing scrub typhus in this region. Methods: We mapped 709 patients from Tamil Nadu, Andhra Pradesh and Telangana who were admitted to the Christian Medical College (CMC Hospital, Vellore, Tamil Nadu, India, for the period 2006-2011, assessed seasonality using monthly counts of scrub typhus cases, and conducted a case-control study among a subset of patients residing in Vellore. Results: The geographic distribution of cases at CMC Hospital clusters around the Tamil Nadu-Andhra Pradesh border. However, distinct hotspots clearly exist distal to this area, near Madurai and the coast in Tamil Nadu, and in the Northeast of Andhra Pradesh. Seasonally, the highest numbers of cases were observed in the cooler months of the year, i.e. September to January. In the case-control analysis, cases were more likely to be agricultural laborers (OR 1.79, 95% CI 1.01 - 3.15, not wear a shirt at home (OR 4.23, 95% CI 1.12 - 16.3, live in houses adjacent to bushes or shrubs (OR 1.95, 95% CI 1.08 - 3.53, and live in a single room home (OR 1.75, 95% CI 1.02 - 3.01. On binary logistic regression, the first three of these variables were statistically significant. Interpretation & conclusions: With the growing number of cases detected in India, scrub typhus is fast emerging as a public health threat and further research to protect the population from this deadly infection is essential. Health education campaigns focusing on the agricultural workers of Southern India, especially during the cooler months of the year, can serve as an important public health measure to
Thinking ahead of the surgeon. An interview study to identify scrub nurses' non-technical skills.
Mitchell, Lucy; Flin, Rhona; Yule, Steven; Mitchell, Janet; Coutts, Kathy; Youngson, George
2011-07-01
Efforts to reduce adverse event rates in healthcare have revealed the importance of identifying the essential non-technical (cognitive and social) skills for safe and effective performance. Previous research on non-technical skills for operating theatre staff has concentrated on doctors rather than nursing professionals. The aim of the study was to identify the critical non-technical skills that are essential for safe and effective performance as an operating theatre scrub nurse. Experienced scrub nurses (n = 25) and consultant surgeons (n = 9) from four Scottish hospitals were interviewed using a semi-structured format. The protocols were designed to identify the main social and cognitive skills required by scrub nurses. Interviews were digitally recorded, transcribed verbatim and independently coded to extract behaviours in order to produce a list of the main non-technical skills for safe and effective scrub nurse performance. The non-technical skills of situation awareness, communication, teamwork, task management and coping with stress were identified as key to successful scrub nurse task performance. Component sets of behaviours for each of these categories were also noted. The interviews with subject matter experts from scrub nursing and surgery produced preliminary evidence that situation awareness, communication, teamwork and coping with stress are the principal non-technical skills required for effective performance as a scrub nurse. Copyright © 2010 Elsevier Ltd. All rights reserved.
Flue gas cleaning by electron beam technology in 21st
International Nuclear Information System (INIS)
Xu Guang; Luo Jingyu; Zhang Ming
2005-01-01
China is paying great attention to the pollution caused by flue gases including sulfur oxides, nitrogen oxides, fine particles, and volatile organic compounds (VOC) for the environmental protection and sustainable development of China economy for 21st century. Among several promising processes, applicable to industrial scale, the electron beam (EB) scrubbing process can simultaneously remove SO 2 , NOx, PM-10 (particulate matter 10 μm or less in diameter), VOC and CO 2 from the flue gas is a new high technology combined with radiation chemistry and electron accelerator technique. The EB flue gas purification process consists of the producing ionization in the EB irradiated gases followed by the formation of free radicals and active species which ultimately forming foggy sulfur acid and nitrate acid. These acids react further with added ammonia to form ammonium sulfate and nitrates as by-products, which can be fertilizer usable in agriculture. The next stage for this technology is its optimization for the reduction of electricity energy consumption and an effective collection of by-products. Lastly the investment cost for EB method is shown to be the most economic compared with other competing methods. (S. Ohno)
New advances in wet scrubbing improvement efficiencies
Energy Technology Data Exchange (ETDEWEB)
Keen, A.R. [Altech Group, Toronto, ON (Canada)
2000-07-01
Wet scrubbing systems are the most versatile and cost efficient of all air pollution abatement technologies. This paper presented System REITHER{sup TM} which is a new generation of venturi scrubber. The advantages of this design are that it is simple and compact, has high removal efficiencies for sub-micron dusts or aerosols and it is flexible to handle any mass flow rate. It also provides high and constant reliability, is easy to control and has the potential to absorb gaseous pollutants. Another advantage is that it can handle corrosive streams through corrosion resistant materials. Innovations in wet scrubbing have made it possible to provide reliable and efficient separation of fine particles, corrosive aerosols and gases. New technology provides industrial engineers with a cost effective option when control air emissions is required. 1 fig.
FLY ASH RECYCLE IN DRY SCRUBBING
The paper describes the effects of fly ash recycle in dry scrubbing. (Previous workers have shown that the recycle of product solids improves the utilization of slaked lime--Ca(OH)2--for sulfur dioxide (SO2) removal by spray dryers with bag filters.) In laboratory-scale experimen...
Numerical Model of SO2 Scrubbing with Seawater Applied to Marine Engines
Directory of Open Access Journals (Sweden)
Lamas M. I.
2016-04-01
Full Text Available The present paper proposes a CFD model to study sulphur dioxide (SO2 absorption in seawater. The focus is on the treatment of marine diesel engine exhaust gas. Both seawater and distilled water were compared to analyze the effect of seawater alkalinity. The results indicate that seawater is more appropriate than distilled water due to its alkalinity, obtaining almost 100% cleaning efficiency for the conditions analyzed. This SO2 reduction meets the limits of SOx emission control areas (SECA when operating on heavy fuel oil. These numerical simulations were satisfactory validated with experimental tests. Such data are essential in designing seawater scrubbers and judging the operating cost of seawater scrubbing compared to alternative fuels.
Non-technical skills of the operating theatre scrub nurse: literature review.
Mitchell, Lucy; Flin, Rhona
2008-07-01
This paper is a report of a review to identify the non-technical (cognitive and social) skills used by scrub nurses. Recognition that failures in non-technical skills contributed to accidents in high-risk industries led to the development of research programmes to study the role of cognition and social interactions in operational safety. Recently, psychological research in operating theatres has revealed the importance of non-technical skills in safe and efficient performance. Most of the studies to date have focused on anaesthetists and surgeons. On-line sources and university library catalogues, publications of the Association for Perioperative Practice, National Association of Theatre Nurses and Association of Peri-Operative Registered Nurses were searched in 2007. Studies were included in the review if they presented data from scrub nurses on one or more of their non-technical skills. These findings were examined in relation to an existing medical non-technical skills framework with categories of communication, teamwork, leadership, situation awareness and decision-making. Of 424 publications retrieved, 13 were reviewed in detail. Ten concerned communication and eight of those also had data on teamwork. In 11 papers teamwork was examined, and one focused on nurses' situation awareness, teamwork and communication. None of the papers we reviewed examined leadership or decision-making by scrub nurses. Further work is needed to identify formally the non-technical skills which are important to the role of scrub nurse and then to design training in the identified non-technical skills during the education and development of scrub nurses.
Skouteris, Dimitrios; Balucani, Nadia; Ceccarelli, Cecilia; Vazart, Fanny; Puzzarini, Cristina; Barone, Vincenzo; Codella, Claudio; Lefloch, Bertrand
2018-02-01
Despite the harsh conditions of the interstellar medium, chemistry thrives in it, especially in star-forming regions where several interstellar complex organic molecules (iCOMs) have been detected. Yet, how these species are synthesized is a mystery. The majority of current models claim that this happens on interstellar grain surfaces. Nevertheless, evidence is mounting that neutral gas-phase chemistry plays an important role. In this paper, we propose a new scheme for the gas-phase synthesis of glycolaldehyde, a species with a prebiotic potential and for which no gas-phase formation route was previously known. In the proposed scheme, the ancestor is ethanol and the glycolaldehyde sister species are acetic acid (another iCOM with unknown gas-phase formation routes) and formic acid. For the reactions of the new scheme with no available data, we have performed electronic structure and kinetics calculations deriving rate coefficients and branching ratios. Furthermore, after a careful review of the chemistry literature, we revised the available chemical networks, adding and correcting several reactions related to glycolaldehyde, acetic acid, and formic acid. The new chemical network has been used in an astrochemical model to predict the abundance of glycolaldehyde, acetic acid, and formic acid. The predicted abundance of glycolaldehyde depends on the ethanol abundance in the gas phase and is in excellent agreement with the measured one in hot corinos and shock sites. Our new model overpredicts the abundance of acetic acid and formic acid by about a factor of 10, which might imply a yet incomplete reaction network.
Seto, J; Suzuki, Y; Nakao, R; Otani, K; Yahagi, K; Mizuta, K
2017-02-01
Climate change, by its influence on the ecology of vectors might affect the occurrence of vector-borne diseases. This study examines the effects of meteorological factors in Japan on the occurrence of scrub typhus, a mite-borne zoonosis caused by Orientia tsutsugamushi. Using negative binomial regression, we analysed the relationships between meteorological factors (including temperature, rainfall, snowfall) and spring-early summer cases of scrub typhus in Yamagata Prefecture, Japan, during 1984-2014. The average temperature in July and August of the previous year, cumulative rainfall in September of the previous year, snowfall throughout the winter, and maximum depth of snow cover in January and February were positively correlated with the number of scrub typhus cases. By contrast, cumulative rainfall in July of the previous year showed a negative relationship to the number of cases. These associations can be explained by the life-cycle of Leptotrombidium pallidum, a predominant vector of spring-early summer cases of scrub typhus in northern Japan. Our findings show that several meteorological factors are useful to estimate the number of scrub typhus cases before the endemic period. They are applicable to establish an early warning system for scrub typhus in northern Japan.
Surveillance of potential hosts and vectors of scrub typhus in Taiwan.
Kuo, Chi-Chien; Lee, Pei-Lung; Chen, Chun-Hsung; Wang, Hsi-Chieh
2015-12-01
Scrub typhus is a lethal infectious disease vectored by larval trombiculid mites (i.e. chiggers) infected with Orientia tsutsugamushi (OT) and recent decades have witnessed an emergence of scrub typhus in several countries. Identification of chigger species and their vertebrate hosts is fundamental for the assessment of human risks to scrub typhus under environmental changes, but intensive and extensive survey of chiggers and their hosts is still lacking in Taiwan. Chiggers were collected from shrews and rodents in nine counties of Taiwan and were assayed for OT infections with nested polymerase chain reaction (PCR). PCR products were further sequenced to reveal probable OT strains. Rodents were assessed for OT exposure by immunofluorescent antibody assay. Lastly, incidence rate of scrub typhus in each county was associated with loads and prevalence of chigger infestations, seropositivity rate in rodents, and OT positivity rate in chiggers. Rattus losea was the most abundant (48.7% of 1,285 individuals) and widespread (occurred in nine counties) small mammal species and hosted the majority of chiggers (76.4% of 128,520 chiggers). Leptotrombidium deliense was the most common (64.9% of all identified chiggers) and widespread (occurred in seven counties) chigger species but was replaced by Leptotrombidium pallidum or Leptotrombidium scutellare during the cold seasons in two counties (Matsu and Kinmen) where winter temperatures were lower than other study sites. Seropositivity rate for OT exposure in 876 assayed rodents was 43.0% and OT positivity rate in 347 pools of chiggers was 55.9%, with 15 OT strains identified in the 107 successfully sequenced samples. Incidence rate of scrub typhus was positively correlated with chigger loads, prevalence of chigger infestations, seropositivity rate but not OT positivity rate in chiggers. Our study reveals R. losea as the primary host for chiggers and there exists a geographical and seasonal variation in chigger species in
Scrub typhus meningitis in a renal transplant recipient
Directory of Open Access Journals (Sweden)
J Dhanapriya
2017-01-01
Full Text Available Scrub typhus is a rickettsial infection commonly seen in Asia. The clinical presentation ranges from nonspecific febrile illness to potentially fatal multiorgan involvement such as liver, kidney, or lung. Central nervous system involvement is uncommon. We report a 45-year-old female renal transplant recipient who presented with fever, headache, meningeal signs, graft dysfunction, and eschar. IgM antibodies against Orientia tsutsugamushi were positive by enzyme-linked immunosorbent assay. Despite oral doxycycline therapy for 5 days, she did not improve but responded well to intravenous azithromycin. To the best of our knowledge, scrub typhus as a cause of meningitis in a renal transplant recipient has not been reported so far.
Improving the technology of purification of gas emissions petrochemical industries
USMANOVA R.R.; ZAIKOV G.E.
2014-01-01
The technology of cleaning of gas emissions flares in the production of synthetic rubber. Developed dynamic scrubber for scrubbing gas emissions. Complex studies served as the basis for the design of an air purification system of industrial premises. Purification of gas emissions before combustion in flares has significantly reduced air pollution by toxic substances.
Clinical indicators for severe prognosis of scrub typhus
Directory of Open Access Journals (Sweden)
Sriwongpan P
2013-10-01
Full Text Available Pamornsri Sriwongpan,1,2 Pornsuda Krittigamas,3 Pacharee Kantipong,4 Naowarat Kunyanone,5 Jayanton Patumanond,1 Sirianong Namwongprom1,61Clinical Epidemiology Program, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 2Department of Social Medicine, Chiang Rai Prachanukroh Hospital, Chiang Rai, Thailand; 3Department of General Pediatrics, Nakornping Hospital, Chiang Mai, Thailand; 4Department of Internal Medicine, 5Department of Medical Technology, Chiang Rai Prachanukroh Hospital, Chiang Rai, Thailand; 6Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, ThailandBackground: The study explored clinical risk characteristics that may be used to forecast scrub typhus severity under routine clinical practices.Methods: Retrospective data were collected from patients registered at two university-affiliated tertiary care hospitals in the north of Thailand, from 2004 to 2010. Key information was retrieved from in-patient records, out patient cards, laboratory reports and registers. Patients were classified into three severity groups: nonsevere, severe (those with at least one organ involvement, and deceased. Prognostic characteristics for scrub typhus severity were analyzed by a multivariable ordinal continuation ratio regression.Results: A total of 526 patients were classified into nonsevere (n = 357, severe (n = 100, and deceased (n = 69. The significant multivariable prognostic characteristics for scrub typhus severity were increased body temperature (odds ratio [OR] = 0.58, 95% confidence interval [CI] = 0.45–0.74, P < 0.001, increased pulse rate (OR = 1.03, 95% CI = 1.01–1.05, P < 0.001, presence of crepitation (OR = 3.25, 95% CI = 1.52–6.96, P = 0.001, increased percentage of lymphocytes (OR = 0.97, 95% CI = 0.95–0.98, P = 0.001, increased aspartate aminotransferase (every 10 IU/L (OR = 1.04, 95% CI = 1.02–1.06, P < 0.001, increased serum albumin (OR = 0.47, 95% CI = 0.27–0.80, P = 0
Wardrop, Nicola A; Kuo, Chi-Chien; Wang, Hsi-Chieh; Clements, Archie C A; Lee, Pei-Fen; Atkinson, Peter M
2013-11-01
Scrub typhus is transmitted by the larval stage of trombiculid mites. Environmental factors, including land cover and land use, are known to influence breeding and survival of trombiculid mites and, thus, also the spatial heterogeneity of scrub typhus risk. Here, a spatially autoregressive modelling framework was applied to scrub typhus incidence data from Taiwan, covering the period 2003 to 2011, to provide increased understanding of the spatial pattern of scrub typhus risk and the environmental and socioeconomic factors contributing to this pattern. A clear spatial pattern in scrub typhus incidence was observed within Taiwan, and incidence was found to be significantly correlated with several land cover classes, temperature, elevation, normalized difference vegetation index, rainfall, population density, average income and the proportion of the population that work in agriculture. The final multivariate regression model included statistically significant correlations between scrub typhus incidence and average income (negatively correlated), the proportion of land that contained mosaics of cropland and vegetation (positively correlated) and elevation (positively correlated). These results highlight the importance of land cover on scrub typhus incidence: mosaics of cropland and vegetation represent a transitional land cover type which can provide favourable habitats for rodents and, therefore, trombiculid mites. In Taiwan, these transitional land cover areas tend to occur in less populated and mountainous areas, following the frontier establishment and subsequent partial abandonment of agricultural cultivation, due to demographic and socioeconomic changes. Future land use policy decision-making should ensure that potential public health outcomes, such as modified risk of scrub typhus, are considered.
Re-caching by Western scrub-jays (Aphelocoma californica cannot be attributed to stress.
Directory of Open Access Journals (Sweden)
James M Thom
Full Text Available Western scrub-jays (Aphelocoma californica live double lives, storing food for the future while raiding the stores of other birds. One tactic scrub-jays employ to protect stores is "re-caching"-relocating caches out of sight of would-be thieves. Recent computational modelling work suggests that re-caching might be mediated not by complex cognition, but by a combination of memory failure and stress. The "Stress Model" asserts that re-caching is a manifestation of a general drive to cache, rather than a desire to protect existing stores. Here, we present evidence strongly contradicting the central assumption of these models: that stress drives caching, irrespective of social context. In Experiment (i, we replicate the finding that scrub-jays preferentially relocate food they were watched hiding. In Experiment (ii we find no evidence that stress increases caching. In light of our results, we argue that the Stress Model cannot account for scrub-jay re-caching.
The genotypes of Orientia tsutsugamushi, identified in scrub typhus patients in northern Vietnam.
Nguyen, Hang L K; Pham, Hang T T; Nguyen, Tinh V; Hoang, Phuong Vm; Le, Mai T Q; Takemura, Taichiro; Hasebe, Futoshi; Hayasaka, Daisuke; Yamada, Akio; Hotta, Kozue
2017-03-01
There are an estimated one million patients with scrub typhus in the Asia-Pacific region. There are few reports describing the incidence of scrub typhus in Vietnam. Blood samples collected from 63 patients clinically diagnosed as having scrub typhus from July 2015 to September 2016 were subjected to genotyping of Orientia tsutsugamushi. Of these patients, 42 (67%) tested positive for O. tsutsugamushi, and the most common genotype was identified to be Karp (55%). Other genotypes, TA763, Gilliam type in Japan variant, and Kato were also found in 17%, 17% and 12% of patients, respectively. To better understand the epidemiological landscape of scrub typhus in Vietnam, a countrywide study is needed. LC110330-LC110333, LC110336-LC110351 and LC214804-LC214825. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Adaptation of a tool to assess non-technical skills of scrub practitioners in Denmark
DEFF Research Database (Denmark)
Mundt, Anna Sofie; Spanager, Lene; Lyk-Jensen, Helle Teglgaard
2017-01-01
The aim of this study was to adapt the Scottish tool, Scrub Practitioners List of Intraoperative Non-Technical Skills, to Danish organisation and culture. With an explorative and qualitative approach, four group interviews with scrub practitioners, surgeons and anaesthesia staff were conducted....... The main differences found were related to communication and teamwork regarding scrub practitioners focus on the team and speaking up. Differences in the non-technical skills described in the behavioural markers are perhaps explained by cultural differences between Scotland and Denmark. A new tool...
Epidemiology of scrub typhus and the eschars patterns in South Korea from 2008 to 2012.
Park, Ji-Hyuk; Kim, Sun-Ja; Youn, Seung-Ki; Park, Kisoo; Gwack, Jin
2014-01-01
In South Korea, scrub typhus is the most common acute febrile illness in autumn. We analyzed scrub typhus cases reported from 2008 to 2012 to describe the epidemiology of scrub typhus as well as eschar patterns. A total of 30,478 cases were reported from 2008 to 2012; the incidence rates were higher in the southern and western regions of South Korea. The common clinical symptoms of confirmed scrub typhus cases from 2010 to 2012 were fever/chills (95.2%), eschars (78.9%), and myalgia (61.7%). The primary sites of eschars were the lower extremities (19.0%), abdomen/waist (13.4%), and axilla (11.5%) in men and the shoulder/frontal chest (15.1%), lower extremities (14.5%), and abdomen/waist (13.6%) in women. Regardless of gender, eschars tended to be more on the lower extremities among the leisure activities group. Among the occupational farm work group, who usually lived in rural areas, eschars appeared most frequently on the abdomen/waist in men and on the shoulder/frontal chest in women. Eschar patterns were influenced by gender and activities. These results could facilitate the prevention of scrub typhus and clarify the current status of scrub typhus in South Korea.
Brushes and picks used on nails during the surgical scrub to reduce bacteria: a randomised trial.
Tanner, J; Khan, D; Walsh, S; Chernova, J; Lamont, S; Laurent, T
2009-03-01
Though brushes are no longer used on the hands and forearms during the surgical scrub, they are still widely used on the nails. The aim of this study was to determine whether nail picks and nail brushes are effective in providing additional decontamination during a surgical hand scrub. A total of 164 operating department staff were randomised to undertake one of the following three surgical hand-scrub protocols: chlorhexidine only; chlorhexidine and a nail pick; or chlorhexidine and a nail brush. Bacterial hand sampling was conducted before and 1h after scrubbing using a modified version of the glove juice method. No statistically significant differences in bacterial numbers were found between any two of the three intervention groups. Nail brushes and nail picks used during surgical hand scrubs do not decrease bacterial numbers and are unnecessary.
THE KNOWLEDGE OF HEALTH CARE WORKERS AND DOCTORS REGARDING HAND SCRUB
Directory of Open Access Journals (Sweden)
Rahul Sanjeev Chaudhary
2016-08-01
Full Text Available BACKGROUND Hand hygiene practices of health care workers has been shown to be an effective measure in preventing hospital acquired infections. This concept has been aptly used to improve understanding, training, monitoring, and reporting hand hygiene among healthcare workers. We conducted this study to assess the knowledge of doctors and health care workers regarding hand scrub. METHODS A study was conducted among doctors and health care workers in a tertiary care hospital. Knowledge was evaluated by using self-structured questionnaire based on the guidelines of hand hygiene prescribed by WHO. RESULTS The awareness and knowledge of preoperative surgical hand scrubbing was moderate in doctors, but unfortunately poor in HCWs. CONCLUSION Our study highlights the need for introducing measures in order to increase the knowledge of preoperative hand scrub in teaching hospital which may translate into good practices.
Factors that affect scrub practitioner non-technical skills: A literature review.
McClelland, Guy
2018-04-01
Non-technical skills are the cognitive and interpersonal behaviours that compliment clinical competence in surgery. Effective use of non-technical skills is essential for scrub practice, because they facilitate anticipation of the surgeon's requirements and promote appropriate communication behaviours. This literature review analyses the factors that may influence a scrub practitioner's use of non-technical skills during surgery. Recommendations are made that are intended to improve their use by reducing behavioural variations during surgery.
Bhargava, Anurag; Kaushik, Reshma; Kaushik, Rajeev Mohan; Sharma, Anita; Ahmad, Sohaib; Dhar, Minakshi; Mittal, Garima; Khanduri, Sushant; Pant, Priyannk; Kakkar, Rajesh
2016-12-01
Scrub typhus is a re-emerging mite-borne rickettsiosis, which continues to be underdiagnosed, with lethal consequences. The present study was conducted to determine the seasonality, clinical presentation and predictors of mortality in patients with scrub typhus at a tertiary care teaching hospital in northern India. Scrub typhus was suspected in patients attending the hospital as per the standard case definition and serological evidence was obtained by performing an IgM ELISA. A total of 284 patients with scrub typhus from urban and rural areas were seen, predominantly from July to November. The most common clinical presentation was a bilateral community-acquired pneumonia (CAP), which resembled pneumonia due to atypical pathogens and often progressed to acute respiratory distress syndrome (ARDS). An acute undifferentiated febrile illness (AUFI) or a febrile illness associated with altered sensorium, aseptic meningitis, shock, abdominal pain, gastrointestinal bleeding or jaundice was also seen. Eschars were seen in 17 per cent of patients, and thrombocytopenia, transaminitis and azotaemia were frequent. There were 24 deaths (8.5%) caused predominantly by ARDS and multi-organ dysfunction. The mortality in patients with ARDS was high (37%). ARDS [odds ratio (OR)=38.29, 95% confidence interval (CI): 9.93, 147.71] and acute kidney injury (OR=8.30, 95% CI: 2.21, 31.21) were the major predictors of death. The present findings indicate that scrub typhus may be considered a cause of CAP, ARDS, AUFI or a febrile illness with multisystem involvement, in Uttarakhand and Uttar Pradesh, especially from July to November. Empiric therapy of CAP may include doxycycline or azithromycin to ensure coverage of underlying unsuspected scrub typhus.
Directory of Open Access Journals (Sweden)
Anurag Bhargava
2016-01-01
Full Text Available Background & objectives: Scrub typhus is a re-emerging mite-borne rickettsiosis, which continues to be underdiagnosed, with lethal consequences. The present study was conducted to determine the seasonality, clinical presentation and predictors of mortality in patients with scrub typhus at a tertiary care teaching hospital in northern India. Methods: Scrub typhus was suspected in patients attending the hospital as per the standard case definition and serological evidence was obtained by performing an IgM ELISA. Results: A total of 284 patients with scrub typhus from urban and rural areas were seen, predominantly from July to November. The most common clinical presentation was a bilateral community-acquired pneumonia (CAP, which resembled pneumonia due to atypical pathogens and often progressed to acute respiratory distress syndrome (ARDS. An acute undifferentiated febrile illness (AUFI or a febrile illness associated with altered sensorium, aseptic meningitis, shock, abdominal pain, gastrointestinal bleeding or jaundice was also seen. Eschars were seen in 17 per cent of patients, and thrombocytopenia, transaminitis and azotaemia were frequent. There were 24 deaths (8.5% caused predominantly by ARDS and multi-organ dysfunction. The mortality in patients with ARDS was high (37%. ARDS [odds ratio (OR=38.29, 95% confidence interval (CI: 9.93, 147.71] and acute kidney injury (OR=8.30, 95% CI: 2.21, 31.21 were the major predictors of death. Interpretation & conclusions: The present findings indicate that scrub typhus may be considered a cause of CAP, ARDS, AUFI or a febrile illness with multisystem involvement, in Uttarakhand and Uttar Pradesh, especially from July to November. Empiric therapy of CAP may include doxycycline or azithromycin to ensure coverage of underlying unsuspected scrub typhus.
First case of scrub typhus with meningoencephalitis from Kerala: An emerging infectious threat
Directory of Open Access Journals (Sweden)
K Saifudheen
2012-01-01
Full Text Available Scrub typhus is a rickettsial disease caused by Orientia tsutsugamushi, one of the most common infectious diseases in the Asia-Pacific region. It has been reported from northern, eastern, and southern India, and its presence has been documented in at least 11 Indian states. However, scrub typhus meningoencephalitis has not been well documented in Kerala. We report two cases of scrub typhus meningoencephalitis from northern Kerala. The diagnosis was made based on the clinical pictures, presence of eschar, and a positive Weil-Felix test with a titer of > 1:320. The first patient succumbed to illness due to respiratory failure and the second patient improved well.
Kang, Seung-Ji; Jin, Hye-Mi; Cho, Young-Nan; Kim, Seong Eun; Kim, Uh Jin; Park, Kyung-Hwa; Jang, Hee-Chang; Jung, Sook-In; Kee, Seung-Jung; Park, Yong-Wook
2017-07-01
Natural killer (NK) cells are essential immune cells against several pathogens. Not much is known regarding the roll of NK cells in Orientia tsutsugamushi infection. Thus, this study aims to determine the level, function, and clinical relevance of NK cells in patients with scrub typhus. This study enrolled fifty-six scrub typhus patients and 56 health controls (HCs). The patients were divided into subgroups according to their disease severity. A flow cytometry measured NK cell level and function in peripheral blood. Circulating NK cell levels and CD69 expressions were significantly increased in scrub typhus patients. Increased NK cell levels reflected disease severity. In scrub typhus patients, tests showed their NK cells produced higher amounts of interferon (IFN)-γ after stimulation with interleukin (IL)-12 and IL-18 relative to those of HCs. Meanwhile, between scrub typhus patients and HCs, the cytotoxicity and degranulation of NK cells against K562 were comparable. CD69 expressions were recovered to the normal levels in the remission phase. This study shows that circulating NK cells are activated and numerically increased, and they produced more IFN-γ in scrub typhus patients.
Directory of Open Access Journals (Sweden)
Seung-Ji Kang
2017-07-01
Full Text Available Natural killer (NK cells are essential immune cells against several pathogens. Not much is known regarding the roll of NK cells in Orientia tsutsugamushi infection. Thus, this study aims to determine the level, function, and clinical relevance of NK cells in patients with scrub typhus.This study enrolled fifty-six scrub typhus patients and 56 health controls (HCs. The patients were divided into subgroups according to their disease severity. A flow cytometry measured NK cell level and function in peripheral blood. Circulating NK cell levels and CD69 expressions were significantly increased in scrub typhus patients. Increased NK cell levels reflected disease severity. In scrub typhus patients, tests showed their NK cells produced higher amounts of interferon (IFN-γ after stimulation with interleukin (IL-12 and IL-18 relative to those of HCs. Meanwhile, between scrub typhus patients and HCs, the cytotoxicity and degranulation of NK cells against K562 were comparable. CD69 expressions were recovered to the normal levels in the remission phase.This study shows that circulating NK cells are activated and numerically increased, and they produced more IFN-γ in scrub typhus patients.
Jimenez, J M
2012-01-01
The operation of the SPS with high intensity bunched beams is limited by the electron cloud building-up in both the arcs and long straight sections. Two consolidation options have been considered: mitigation of the electron cloud using coatings or relying, as before, on the scrubbing runs. A status report on both options will be given with a particular emphasis on measurements plans for 2012 and pending issues. The testing needs, corresponding beam parameters and MD time in 2012 will be addressed. The criteria for the decision making and the corresponding schedule will be discussed.
International Nuclear Information System (INIS)
Polo, J.; Herranz, L.E.; Peyres, V.; Escudero, M.
1996-01-01
During a hypothetical nuclear reactor accident with core damage the fission products released from the degrading fuel bundles often pass through aqueous beds before entering the containment, mitigating in part the source term. Several computer codes have been developed for predicting the fission product and aerosols removal in pool scrubbing scenarios. In addition to particle removal, these codes simulate the retention of some volatile iodine compounds. Nonetheless, experimental data on the matter are rather scarce and further validation remains to be done. In this work a review of volatile iodine removal models included in SPARC and BUSCA codes is presented. Besides, the results and discussions of a validation of both codes against the available experimental data are summarized. SPARC and BUSCA codes model the diffusion of iodine toward the bubble interface by using the film penetration theory, which assumes a double layer gas-liquid at the interface. However, there are some differences between the two models, mainly related to the boundary conditions in the aqueous volume for the diffusion of molecular iodine. In SPARC, a set of fast reactions in the liquid phase control both the molecular iodine concentration in the pool and the partition coefficient of iodine at the interface. Thus, the aqueous chemistry plays an important role in the boundary conditions for the diffusion process. On the contrary, the BUSCA model has no chemical considerations at all, and assumes a null iodine concentration in the water bulk. Several sensitivity studies have been made in order to weight the effect of these differences. The variables examined in these studies were the pool temperature and the incoming iodine concentration in the pool. Additionally, sensitivity studies focused on the steam mass fraction of the injected gas were performed to study the effect of the different approach of both models for the condensation process. The results showed a different sensitivity of SPARC
Flue gas desulfurization: Physicochemical and biotechnological approaches
Energy Technology Data Exchange (ETDEWEB)
Pandey, R.A.; Biswas, R.; Chakrabarti, T.; Devotta, S. [National Environmental Engineering Research Institute, Nagpur (India)
2005-07-01
Various flue gas desulfurization processes - physicochemical, biological, and chemobiological - for the reduction of emission of SO{sub 2} with recovery of an economic by-product have been reviewed. The physicochemical processes have been categorized as 'once-through' and 'regenerable.' The prominent once-through technologies include wet and dry scrubbing. The wet scrubbing technologies include wet limestone, lime-inhibited oxidation, limestone forced oxidation, and magnesium-enhanced lime and sodium scrubbing. The dry scrubbing constitutes lime spray drying, furnace sorbent injection, economizer sorbent injection, duct sorbent injection, HYPAS sorbent injection, and circulating fluidized bed treatment process. The regenerable wet and dry processes include the Wellman Lord's process, citrate process, sodium carbonate eutectic process, magnesium oxide process, amine process, aqueous ammonia process, Berglau Forchung's process, and Shell's process. Besides these, the recently developed technologies such as the COBRA process, the OSCAR process, and the emerging biotechnological and chemobiological processes are also discussed. A detailed outline of the chemistry, the advantages and disadvantages, and the future research and development needs for each of these commercially viable processes is also discussed.
Clinico - Laboratory Profile of Scrub Typhus - An Emerging Rickettsiosis in India.
Narayanasamy, Dinesh Kumar; Arunagirinathan, Arul Kumaran; Kumar, Revathi Krishna; Raghavendran, V D
2016-11-01
To study the clinical and laboratory profile of pediatric scrub typhus in rural south India. This is a descriptive study of the clinical and laboratory features of 117 children with IgM ELISA proven scrub typhus out of 448 children, who were admitted in the Pediatric ward of a tertiary care hospital, during the study period of November 2014 through March 2015. Fever was present in all 117 children, with mean duration of fever at admission as 9 d. Gastrointestinal tract was the most commonly affected system, seen in 51 % of children. Cough (82 %), myalgia (70 %), vomiting (68 %), headache (45 %) and pain abdomen (42 %) were the most common symptoms of scrub typhus. Hepatomegaly (70), splenomegaly (53 %), pallor (50 %) and eschar (41 %) were the common clinical findings in children with scrub typhus. Out of 49 children with eschar, 32 were associated with regional lymphadenopathy, which was commonly seen in axillary, neck and groin regions. Leucocytosis (50 %), anemia (56 %), increased SGOT / SGPT (47 %), thrombocytopenia (41 %), hypoalbuminemia (40 %) and hyponatremia (40 %) were the common lab features. Shock (46 %), myocarditis (24 %) and pneumonia (16 %) were the common complications seen in these children. This study showed that early treatment for scrub typhus results in a good outcome in terms of early recovery and nil mortality. Regional lymphadenopathy is a marker of hidden or developing eschar. Total count and differential count should be interpreted on the background of the duration of fever. Since IgM ELISA, which is diagnostic of scrub typhus may not be widely available, any febrile child coming from rural area with hepatosplenomegaly, pallor, eschar, generalised / regional lymphadenopathy, anemia, leucocytosis, thrombocytopenia and increased Aspartate transaminase (AST) /Alanine aminotransferase (ALT) should be started on empirical Doxycycline or Azithromycin in order to prevent life threatening complications secondary to delay in
Chen, Y Z; Li, F; Xu, H; Huang, L C; Gu, Z G; Sun, Z Y; Yan, G J; Zhu, Y J; Tang, C
2016-02-01
In order to provide better programs on monitoring, early warning and prevention of Scrub Typhus in the coastal beach area, temporal-spatial distribution characteristics of scrub typhus were summarized. Relationships between temporal-spatial clustering of Scrub Typhus, meteorological factors, rodent distribution and the biological characteristics in coastal beach area of Yancheng city, were studied. Reports on network-based Scrub Typhus epidemics and information on population, weather situation through monitoring those stations, from 2005 to 2014 were collected and processed, in the coastal beach area of Yancheng city. Distribution, density of the population concerned and seasonal fluctuation on rodents were monitored in coastal beach area, from April 2011 to December, 2013. METHODS as descriptive statistics, space-time permutation scantistics, autocorrelation and Cross-correlation analysis etc, were used to analyze the temporal-spatial distribution of Scrub Typhus and correlation with rodent distribution, density fluctuation and meteorological indexes. Zero-inflated Pearson (ZIP) regression model was contributed according to the distribution of related data. All methods were calculated under Excel 2003, SPSS 16.0, Mapinfo 11.0, Satscan 9.0 and Stata/SE 10.0 softwares. (1) The incidence of Scrub Typhus was gradually increasing and the highest incidence of the year was seen in 2014, as 5.81/10 million. There was an autumn peak of Scrub typhus, with the highest incidence rate as 12.02/10 million in November. The incidence rate of Scrub typhus appeared high in Binhai, Dafeng and Xiangshui, with the average incidence rates appeared as 3.30/10 million, 3.21/10 million and 2.79/10 million, respectively. There were 12 towns with high incidence rates in the coastal beach area, with incidence rate showed between 4.41/10 and 10.03/10 million. (2) There were three incidence clusters of Scrub typhus seen in 25 towns, between October 2012 and November 2012 in Dongtai, Dafeng
Mechanisms of acid, weakly acidic and gas reflux after anti-reflux surgery
Bredenoord, A. J.; Draaisma, W. A.; Weusten, B. L. A. M.; Gooszen, H. G.; Smout, A. J. P. M.
2008-01-01
BACKGROUND: Whereas it is well documented that fundoplication reduces acid reflux, the effects of the procedure on non-acid and gas reflux and the mechanisms through which this is achieved have not been fully elucidated. METHODS: In 14 patients, reflux was measured with impedance-pH monitoring
Technical and economical aspects of SO2 and NOx removal from flue gas by electron beam irradiation
International Nuclear Information System (INIS)
Turhan, S.; Karadeniz, S.; Tugluoglu, N.; Eken, M.; Oktar, O.; Ercan, I.
2001-01-01
The emission of sulfur dioxide (SO 2 , also SO 3 ) and nitrogen oxides (NO, NO 2 , called NO x ) from fossil fuel burning power and industrial plants is one of the major sources of environmental pollution. These pollutants are named as acid gases causing acid rain and also indirect greenhouse gases contributing greenhouse effect. Acid rain damages forest, agriculture fields and flora, and cause public health concerns in regions having a number of industrial plants. Today, many countries have started to impose industrial emission limits and this movement has generated renewed interest in finding viable and cost effective solutions to SO 2 and NO x pollution control. The conventional technologies, wet scrubbing de-SO 2 and de-NO x , now reached their full potential therefore these methods are not expected to provide further improvements in terms of efficiency or reduction in construction costs. However, new technologies are being investigated for industrial scale commercial viability. One of them is electron beam process, which is dry scrubbing process and simultaneously removes SO 2 and NO x , and useful by-product for agriculture fertilizer. In this study, the economical and technical aspects of electron beam flue gas treatment process are discussed. Because an electron accelerator facility with electron beam energy of 500 KeV and electron beam current of 20 mA will be installed at ANRTC in TURKEY
Louisiana Geographic Information Center — This data set contains Environmental Sensitivity Index (ESI) scrub-shrub and wetlands data of coastal Louisiana. The ESI is a classification and ranking system,...
Severe scrub typhus infection: Clinical features, diagnostic challenges and management
Peter, John Victor; Sudarsan, Thomas I; Prakash, John Anthony J; Varghese, George M
2015-01-01
Scrub typhus infection is an important cause of acute undifferentiated fever in South East Asia. The clinical picture is characterized by sudden onset fever with chills and non-specific symptoms that include headache, myalgia, sweating and vomiting. The presence of an eschar, in about half the patients with proven scrub typhus infection and usually seen in the axilla, groin or inguinal region, is characteristic of scrub typhus. Common laboratory findings are elevated liver transaminases, thrombocytopenia and leukocytosis. About a third of patients admitted to hospital with scrub typhus infection have evidence of organ dysfunction that may include respiratory failure, circulatory shock, mild renal or hepatic dysfunction, central nervous system involvement or hematological abnormalities. Since the symptoms and signs are non-specific and resemble other tropical infections like malaria, enteric fever, dengue or leptospirosis, appropriate laboratory tests are necessary to confirm diagnosis. Serological assays are the mainstay of diagnosis as they are easy to perform; the reference test is the indirect immunofluorescence assay (IFA) for the detection of IgM antibodies. However in clinical practice, the enzyme-linked immuno-sorbent assay is done due to the ease of performing this test and a good sensitivity and sensitivity when compared with the IFA. Paired samples, obtained at least two weeks apart, demonstrating a ≥ 4 fold rise in titre, is necessary for confirmation of serologic diagnosis. The mainstay of treatment is the tetracycline group of antibiotics or chloramphenicol although macrolides are used alternatively. In mild cases, recovery is complete. In severe cases with multi-organ failure, mortality may be as high as 24%. PMID:26261776
Directory of Open Access Journals (Sweden)
Hyun Lee Kim
2012-06-01
Full Text Available Acid-base unbalance is most common problem in severe ill patient, especially in condition of abnormal renal function state. Acid-base unbalances are respiratory acidosis, respiratory alkalosis, metabolic acidosis, and metabolic alkalosis. Metabolic acidosis is frequently appeared in clinical state. Arterial blood gas analysis is considered as a basic test to the intensive care unit patient and emergency state. Recently some researches were done, comparing with arterial blood gas analysis and venous blood gas analysis. Because of venous blood sampling is safer than arterial blood gas analysis, and beside not so different among them for detecting pH, pCO2, HCO3, except pO2 measuring. This research was done in emergency room, and for explaining no different between arterial blood gas analysis and peripheral blood gas analysis result in acid-base unbalance state patient. Especially in kidney functions decreased state. : The study was done from March, 2010 to January, 2011. The object was 89 peoples who came to emergency room for treating internal medicine problem. (Women 53, average age: 66.7±12.1 Then compare between arterial blood gas analysis and peripheral blood gas analysis. Result: The mean arterial minus venous difference for pH, pCO2, and bicarbonate was −0.0170, 2.6528, and 0.6124. Bland-Altman plot was done for predicting agreement of two groups, and the scale was pH −2.95 to 4.17, pCO2 −4.45 to 9.76, bicarbonate −2.95 to 4.16, in 95% relative. Conclusion: The peripheral blood gas pH, pCO2, bicarbonate level is almost same as arterial blood gas analysis results. And enough to measuring acid-base unbalance state, in absent of arterial blood testing.
A comparative study of hepatitis caused by scrub typhus and viral hepatitis A in South Korea.
Lee, Jun; Kim, Dong-Min; Yun, Na Ra; Byeon, Yu Mi; Kim, Young Dae; Park, Chan Guk; Kim, Man Woo; Han, Mi Ah
2011-11-01
We compared clinical features and laboratory findings of 104 patients with hepatitis A and 197 patients with scrub typhus. Nausea, vomiting, abdominal pain, hepatomegaly, and jaundice were common in patient with hepatitis A, and fever and headache were significantly more common in patients with scrub typhus. At presentation, an alanine aminotransferase (ALT) level ≥ 500 U/L was observed in 1% of scrub typhus patients and in 87.5% of hepatitis A patients (P hepatitis A patients. The ALT:lactate dehydrogenase ratio was ≤ 5 in 97.4% of the patients with scrub typhus and > 5 in 95.2% of those with hepatitis A (P 5, and hepatomegaly are indications of viral hepatitis A.
A Comparative Study of Hepatitis Caused by Scrub Typhus and Viral Hepatitis A in South Korea
Lee, Jun; Kim, Dong-Min; Yun, Na Ra; Byeon, Yu Mi; Kim, Young Dae; Park, Chan Guk; Kim, Man Woo; Han, Mi Ah
2011-01-01
We compared clinical features and laboratory findings of 104 patients with hepatitis A and 197 patients with scrub typhus. Nausea, vomiting, abdominal pain, hepatomegaly, and jaundice were common in patient with hepatitis A, and fever and headache were significantly more common in patients with scrub typhus. At presentation, an alanine aminotransferase (ALT) level ≥ 500 U/L was observed in 1% of scrub typhus patients and in 87.5% of hepatitis A patients (P hepatitis A patients. The ALT:lactate dehydrogenase ratio was ≤ 5 in 97.4% of the patients with scrub typhus and > 5 in 95.2% of those with hepatitis A (P 5, and hepatomegaly are indications of viral hepatitis A. PMID:22049041
Advanced separation technology for flue gas cleanup. Final report, February 1998
Energy Technology Data Exchange (ETDEWEB)
Bhown, A.S.; Alvarado, D.; Pakala, N.; Tagg, T.; Riggs, T.; Ventura, S.; Sirkar, K.K.; Majumdar, S.; Bhaumick, D.
1998-06-01
The objective of this work by SRI International was to develop a novel system for regenerable SO{sub 2} and NO{sub x} scrubbing of flue gas that focuses on (1) a novel method for regenerating spent SO{sub 2} scrubbing liquor and (2) novel chemistry for reversible absorption of NO{sub x}. High efficiency, hollow fiber contactors (HFCs) were proposed as the devices for scrubbing the SO{sub 2} and NO{sub x} from the flue gas. The system would be designed to remove more than 95% of the SO{sub 2} and more than 75% of the NO{sub x} from flue gases typical of pulverized coal-fired power plants at a cost that is at least 20% less than combined wet limestone scrubbing of SO{sub x} and selective catalytic reduction of NO{sub x}. In addition, the process would generate only marketable by-products, if any (no waste streams are anticipated). The major cost item in existing technology is capital investment. Therefore, the approach was to reduce the capital cost by using high-efficiency, hollow fiber devices for absorbing and desorbing the SO{sub 2} and NO{sub x}. The authors also introduced new process chemistry to minimize traditionally well-known problems with SO{sub 2} and NO{sub x} absorption and desorption. The process and progress in its development are described.
Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.
Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won
2016-08-01
Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.
An Experimental and Computational Study of the Gas-Phase Acidities of the Common Amino Acid Amides.
Plummer, Chelsea E; Stover, Michele L; Bokatzian, Samantha S; Davis, John T M; Dixon, David A; Cassady, Carolyn J
2015-07-30
Using proton-transfer reactions in a Fourier transform ion cyclotron resonance mass spectrometer and correlated molecular orbital theory at the G3(MP2) level, gas-phase acidities (GAs) and the associated structures for amides corresponding to the common amino acids have been determined for the first time. These values are important because amino acid amides are models for residues in peptides and proteins. For compounds whose most acidic site is the C-terminal amide nitrogen, two ions populations were observed experimentally with GAs that differ by 4-7 kcal/mol. The lower energy, more acidic structure accounts for the majority of the ions formed by electrospray ionization. G3(MP2) calculations predict that the lowest energy anionic conformer has a cis-like orientation of the [-C(═O)NH](-) group whereas the higher energy, less acidic conformer has a trans-like orientation of this group. These two distinct conformers were predicted for compounds with aliphatic, amide, basic, hydroxyl, and thioether side chains. For the most acidic amino acid amides (tyrosine, cysteine, tryptophan, histidine, aspartic acid, and glutamic acid amides) only one conformer was observed experimentally, and its experimental GA correlates with the theoretical GA related to side chain deprotonation.
Microbial aspects of synthesis gas fed bioreactors treating sulfate and metal rich wastewaters
Houten, van B.H.G.W.
2006-01-01
The use of synthesis gas fed sulfate-reducing bioreactors to simultaneously remove both oxidized sulfur compounds and metals shows great potential to treat wastewaters generated as a result of flue gas scrubbing, mining activities and galvanic processes. Detailed information about the phylogenetic
SCRUB versus trade: Enemies or allies?
International Nuclear Information System (INIS)
Platt, J.B.
1992-01-01
Under the 1990 Clean Air Act Amendments (CAAA), scrubbing and emission allowance trading will play complementary roles. This paper reviews Phase I announced strategies and presents projections of technology controls, coal switching and industry-wide SO 2 removal costs under different assumptions about trading. The principal uncertainties characterizing today's planning environment are discussed -- ranging from changing expectations for fuel costs to swings in allowance prices and questions about regulation and new operating procedures. Economic forecasting is difficult. A clearer picture of Phase 2 strategies is emerging from EPRI's integrated analysis of fuel, technology and allowance markets -- based on collaboration between A. Van Horn and K. White (management consultants) and T. Hewson (Energy Ventures Analysis). About half the SO 2 reductions required in Phase 2 are likely to come from technology controls and half from coal switching. With trading, the highest cost open-quotes scrubsclose quotes and open-quotes switchesclose quotes can be avoided, more upgrading of low-cost scrubbing is expected, and the role of switching grows to a small extent. Additional benefits from trading, averaging and banking allowances are: better sequencing of technology controls, less stringent specs for equipment, and added flexibility/risk-sharing opportunities in contract arrangements
International Nuclear Information System (INIS)
Jimenez, J.M.
2012-01-01
The operation of the SPS with high intensity bunched beams is limited by the electron cloud building-up in both the arcs and long straight sections. Two consolidation options have been considered: suppression of the electron cloud build-up using coatings or relying, as before, on the scrubbing mitigation. A status report on both options will be given with a particular emphasis on measurements plans for 2012 and pending issues. The testing needs, corresponding beam parameters and MD time in 2012 will be addressed. The criteria for the decision making and the corresponding schedule will be discussed. (author)
Simultaneous treatment of SO2 containing stack gases and waste water
Poradek, J. C.; Collins, D. D. (Inventor)
1978-01-01
A process for simultaneously removing sulfur dioxide from stack gases and the like and purifying waste water such as derived from domestic sewage is described. A portion of the gas stream and a portion of the waste water, the latter containing dissolved iron and having an acidic pH, are contacted in a closed loop gas-liquid scrubbing zone to effect absorption of the sulfur dioxide into the waste water. A second portion of the gas stream and a second portion of the waste water are controlled in an open loop gas-liquid scrubbing zone. The second portion of the waste water contains a lesser amount of iron than the first portion of the waste water. Contacting in the openloop scrubbing zone is sufficient to acidify the waste water which is then treated to remove solids originally present.
Frequent contamination of nursing scrubs is associated with specific care activities.
Thom, Kerri A; Escobar, Daniel; Boutin, Mallory A; Zhan, Min; Harris, Anthony D; Johnson, J Kristie
2018-05-01
The objective of this article is to assess health care worker (HCW) and patient care factors associated with bacterial contamination of scrubs. We performed a cohort study of critical care HCWs. Participants were given 4 sets of new scrubs; each set was sampled 8 times during the 8-month study period on random days in the last 4 hours of the shift. Total colony counts and presence of prespecified pathogenic bacteria were assessed. Generalized estimating equation was used to identify factors associated with contamination. There were 720 samples obtained from 90 HCWs; 30% of samples were contaminated with pathogenic bacteria. Multivariate analysis showed that providing care for patients with wounds (odds ratio [OR], 1.75; 95% confidence interval [CI], 1.17-2.62; P contamination. A second model showed the average log colony count of bacterial contamination of scrubs was higher when a bath was given (log colony count difference, 0.21; P = .05) but lower among HCWs assigned to care for at least 1 patient on contact precautions (log colony count difference, 0.28; P contaminated with bacteria. Providing care for patients with wounds or giving a bath were associated with scrub contamination by pathogenic bacteria. However, the amount of contamination was lower among HCWs who were assigned to care for patients on contact precautions. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
[Spatial analysis of autumn-winter type scrub typhus in Shandong province, 2006-2014].
Yang, H; Bi, Z W; Kou, Z Q; Zheng, L; Zhao, Z T
2016-05-01
To discuss the spatial-temporal distribution and epidemic trends of autumn-winter type scrub typhus in Shandong province, and provide scientific evidence for further study for the prevention and control of the disease. The scrub typhus surveillance data during 2006-2014 were collected from Shandong Disease Reporting Information System. The data was analyzed by using software ArcGIS 9.3(ESRI Inc., Redlands, CA, USA), GeoDa 0.9.5-i and SatScan 9.1.1. The Moran' s I, log-likelihood ratio(LLR), relative risk(RR)were calculated and the incidence choropleth maps, local indicators of spatial autocorrelation cluster maps and space scaning cluster maps were drawn. A total of 4 453 scrub typhus cases were reported during 2006-2014, and the annual incidence increased with year. Among the 17 prefectures(municipality)in Shandong, 13 were affected by scrub typhus. The global Moran's I index was 0.501 5(Pscrub typhus in Shandong. Since 2006, the epidemic area of the disease has expanded and the number of high-risk areas has increased. Moreover, the eastward moving and periodically expanding trends of high-risk clusters were detected.
Chin, Jung Yeon; Kang, Ki-Woon; Moon, Kyung Min; Kim, Jongwoo; Choi, Yu Jeong
2018-03-01
Scrub typhus is known as a self-limited infectious disease. Cardiac complication is uncommon and usually not life-threatening. Until now, few cases of fulminant myocarditis by scrub typhus have been reported. So, we investigated incidence and predictors of acute myocarditis in severe scrub typhus. We retrospectively reviewed 89 patients among 91 scrub typhus confirmed patients who examined an echocardiogram and cardiac biomarkers from 2005 to 2015 in the intensive care unit at our hospital. We excluded two patients who didn't have electrocardiography. Patients were divided into two groups and compared between scrub typhus with (n = 13) and without (n = 76) acute myocarditis. Age, sex, and underlying diseases were similar between the groups. The existence of eschar and duration of general ache and fever were similar between the groups. However, patients with acute myocarditis had more elevated total bilirubin, high incidence of ST elevations and paroxysmal atrial fibrillation (PAF) than those without acute myocarditis. Receiver operating characteristic analysis showed that the PAF was a predictor of myocarditis with a sensitivity of 70% and specificity of 84%. Predictive power of combination of ST-segment elevation and PAF was significantly associated with myocarditis in the multivariate analysis (odds ratio, 1.57; 95% confidence interval [CI], 1.21 to 11.7; p = 0.041) and area under the curve was 0.947 (95% CI, 0.878 to 0.983; p scrub typhus may be more common than previously reported. Patients with high bilirubin and PAF are at increased risk of acute myocarditis with scrub typhus. These patients warrant closer follow-up and echocardiogram would be needed.
Sivarajan, Sunuraj; Shivalli, Siddharudha; Bhuyan, Debomallya; Mawlong, Michael; Barman, Rittwick
2016-10-05
India is an integral component of "tsutsugamushi triangle" which depicts a part of the globe endemic to scrub typhus. Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is described as a re-emerging infectious disease in India. The present study aimed to study the clinical and paraclinical profile, complications and predictors of outcome among 90 cases of scrub typhus diagnosed in a hospital of north-eastern India from Sept 2011 to Aug 2012. A longitudinal study was conducted in a hospital of Meghalaya, India between Sept 2011 and Aug 2012. Diagnosis of scrub typhus was arrived by SD BIOLINE tsutsugamushi (solid phase immunochromatographic assay) rapid diagnostic test for antibodies (IgM, IgG or IgA). Descriptive analyses of age, gender, geographic area, symptoms and signs, treatment, laboratory findings, complications, and outcome were conducted. Relative risk (RR) with 95 % confidence interval (CI) was computed for Multiple Organ Dysfunction Syndrome (MODS) and mortality. Binary logistic regression was applied to the significant correlates (P scrub typhus. As many as 662 clinically suspected scrub typhus patients were tested and 90 (13.6 %) were diagnosed to have scrub typhus. Out of 90 patients, 52.2 % (n = 47) were males and their mean (SD) age was 36.29 (13.38) years. Fever of 1.5 mg/dl, and transaminase (AST, ALT or both) >500 U/L were associated with MODS (P 3 mg/dl was also associated with MODS (P 1.5 mg/dl was a predictor of MODS (OR: 76.1, 95 % CI: 4.9-1175.6) and mortality (OR: 18.03, 95 % CI: 1.38-235.1). In this study setting, approximately one-seventh (13.6 %) of the acute undifferentiated febrile illness were due to scrub typhus. Systemic complications were common (33.3 %). Serum creatinine >1.5 mg/dl was a predictor of MODS and mortality.
BIONOMIK TUNGAU VEKTOR SCRUB TYPHUS DAN HOSPESNYA DI DAERAH TRANSMIGRASI KUMPEH, JAMBI
Directory of Open Access Journals (Sweden)
Ima Nurisa
2012-09-01
Full Text Available A study on bionomics of scrub typhus vector and its host species was conducted in a transmigration scheme of Kumpeh, Jambi, Sumatera. Ten species of trombiculid mites were collected from 6 species of rats and 2 species of squirrels. Leptotrombidium (L. deliense, a known vectorof scrub typhus vector elsewhere, was found mostly on Rattus tiomanicus. This rat species was widely distributed in forest, disturbed land and cultivated land habitations found in the study area. Chigger infestations on R. tiomanicus trapped in disturbed land were 63.6% — 81.8%. The average number of chigger collected from disturbed land was highest in December, from forest habitation was in October and from the cultivated land habitation was in November. Rattus tiomanicus was found to be a potential rat species for maintaining the natural cycle of scrub typhus in the study area.
Jung, Ho-Chul; Chon, Sung-Bin; Oh, Won Sup; Lee, Dong-Hyun; Lee, Ho-Jin
2015-01-01
Scrub typhus usually presents as acute undifferentiated fever. This cross-sectional study included adult patients presenting with acute undifferentiated fever defined as any febrile illness for ≤ 14 days without evidence of localized infection. Scrub typhus cases were defined by an antibody titer of a ≥ fourfold increase in paired sera, a ≥ 1:160 in a single serum using indirect immunofluorescence assay, or a positive result of the immunochromatographic test. Multiple regression analysis identified predictors associated with scrub typhus to develop a prediction rule. Of 250 cases with known etiology of acute undifferentiated fever, influenza (28.0%), hepatitis A (25.2%), and scrub typhus (16.4%) were major causes. A prediction rule for identifying suspected cases of scrub typhus consisted of age ≥ 65 years (two points), recent fieldwork/outdoor activities (one point), onset of illness during an outbreak period (two points), myalgia (one point), and eschar (two points). The c statistic was 0.977 (95% confidence interval = 0.960–0.994). At a cutoff value ≥ 4, the sensitivity and specificity were 92.7% (79.0–98.1%) and 90.9% (86.0–94.3%), respectively. Scrub typhus, the third leading cause of acute undifferentiated fever in our region, can be identified early using the prediction rule. PMID:25448236
International Nuclear Information System (INIS)
Rimshaw, S.J.; Case, F.N.; Tompkins, J.A.
1980-02-01
The nitrate anion is the predominant constituent in all high-level nuclear wastes. Formic acid reacts with the nitrate anion to yield noncondensable, inert gases (N 2 or N 2 O), which can be scrubbed free of 106 Ru, 129 I, and 99 Tc radioactivities prior to elimination from the plant by passing through HEPA filters. Treatment of a high-level authentic radioactive waste with two moles of formic acid per mole of nitrate anion leads to a low RuO 4 volatility of about 0.1%, which can be reduced to an even lower level of 0.007% on adding a 15% excess of formic acid. Without pretreatment of the nitrate waste with formic acid, a high RuO 4 volatility of approx. 35% is observed on calcining a 4.0 N HNO 3 solution in quartz equipment at 350 0 C. The RuO 4 volatility falls to approx. 1.0% on decreasing the initial HNO 3 concentration to 1.0 N or lower. It is postulated that thermal denitration of a highly nitrated ruthenium complex leads to the formation of volatile RuO 4 , while decarboxylation of a ruthenium-formate complex leads to the formation of nonvolatile RuO 2 . Wet scrubbing with water is used to remove RuO 4 from the off-gas stream. In all glass equipment, small amounts of particulate RuO 2 are formed in the gas phase by decomposition of RuO 4 . The 99 Tc volatility was found to vary from 0.2 to 1.4% on calcining HNO 3 and HCOOH (formic acid) solutions over the temperature range of 250 to 600 0 C. These unexpectedly low volatilities of 99 Tc are correlated to the high thermal stability limits of various metal pertechnetates and technetates. Iodine volatilities were high, varying from a low of 30% at 350 0 C to a high of 97% at 650 0 C. It is concluded that with a proper selection of pretreatment and operating conditions the 106 Ru and 99 Tc activities can be retained in the calcined solid with recycle of the wet scrubbing solution
Clinical significance of hypoalbuminemia in outcome of patients with scrub typhus
Directory of Open Access Journals (Sweden)
Kwon Keun-Sang
2010-07-01
Full Text Available Abstract Background This study was designed to investigate the clinical significance of hypoalbuminemia as a marker of severity and mortality in patients with Scrub typhus. Methods The patients with scrub typhus were divided into two groups based on the serum albumin levels; Group I (serum albumin Results Of the total 246 patients who underwent the study, 84 patients (34.1% were categorized as Group I and 162 patients were (65.9% as Group II. Group I showed significantly higher incidence of confusion (24.6% vs. 5.3%, p p = 0.002, pleural effusion (22.8% vs. 11.1%, p = 0.03, arrhythmia (12.3% vs. 2.6%, p = 0.008 and non-oliguric acute renal failure (40.4% vs. 11.1%, p p p = 0.012, and higher hospital cost compared to Group II. Conclusions This study showed hypoalbuminemia in scrub typhus was closely related to the frequency of various complication, longer hospital stay, consequently the higher medical cost, necessitating more efficient management of patients, including medical resources.
Formation of itraconazole-succinic acid cocrystals by gas antisolvent cocrystallization.
Ober, Courtney A; Gupta, Ram B
2012-12-01
Cocrystals of itraconazole, an antifungal drug with poor bioavailability, and succinic acid, a water-soluble dicarboxylic acid, were formed by gas antisolvent (GAS) cocrystallization using pressurized CO(2) to improve itraconazole dissolution. In this study, itraconazole and succinic acid were simultaneously dissolved in a liquid solvent, tetrahydrofuran, at ambient conditions. The solution was then pressurized with CO(2), which decreased the solvating power of tetrahydrofuran and caused crystallization of itraconazole-succinic acid cocrystals. The cocrystals prepared by GAS cocrystallization were compared to those produced using a traditional liquid antisolvent, n-heptane, for crystallinity, chemical structure, thermal behavior, size and surface morphology, potential clinical relevance, and stability. Powder X-ray diffraction, Fourier transform infrared spectroscopy, differential scanning calorimetry, and scanning electron microscopy analyses showed that itraconazole-succinic acid cocrystals with physical and chemical properties similar to cocrystals produced using a traditional liquid antisolvent technique can be prepared by CO(2) antisolvent cocrystallization. The dissolution profile of itraconazole was significantly enhanced through GAS cocrystallization with succinic acid, achieving over 90% dissolution in less than 2 h. The cocrystals appeared stable against thermal stress for up to 4 weeks under accelerated stability conditions, showing only moderate decreases in their degree of crystallinity but no change in their crystalline structure. This study shows the utility of an itraconazole-succinic acid cocrystal for improving itraconazole bioavailability while also demonstrating the potential for CO(2) to replace traditional liquid antisolvents in cocrystal preparation, thus making cocrystal production more environmentally benign and scale-up more feasible.
Astrup, Elisabeth; Janardhanan, Jeshina; Otterdal, Kari; Ueland, Thor; Prakash, John A J; Lekva, Tove; Strand, Øystein A; Abraham, O C; Thomas, Kurien; Damås, Jan Kristian; Mathews, Prasad; Mathai, Dilip; Aukrust, Pål; Varghese, George M
2014-02-01
Scrub typhus, caused by Orientia tsutsugamushi, is endemic in the Asia-Pacific region. Mortality is high if untreated, and even with treatment as high as 10-20%, further knowledge of the immune response during scrub typhus is needed. The current study was aimed at comparing plasma levels of a variety of inflammatory mediators in scrub typhus patients and controls in South India in order to map the broader cytokine profile and their relation to disease severity and clinical outcome. We examined plasma levels of several cytokines in scrub typhus patients (n = 129) compared to healthy controls (n = 31) and infectious disease controls (n = 31), both in the acute phase and after recovery, by multiplex technology and enzyme immunoassays. Scrub typhus patients were characterized by marked changes in the cytokine network during the acute phase, differing not only from healthy controls but also from infectious disease controls. While most of the inflammatory markers were raised in scrub typhus, platelet-derived mediators such as RANTES were markedly decreased, probably reflecting enhanced platelet activation. Some of the inflammatory markers, including various chemokines (e.g., interleukin-8, monocyte chemoattractant peptide-1 and macrophage inflammatory protein-1β) and downstream markers of inflammation (e.g., C-reactive protein and pentraxin-3), were also associated with disease severity and mortality during follow-up, with a particular strong association with interleukin-8. Our findings suggest that scrub typhus is characterized by a certain cytokine profile that includes dysregulated levels of a wide range of mediators, and that this enhanced inflammation could contribute to disease severity and clinical outcome.
Counter current extraction of phosphoric acid: Food grade acid production
International Nuclear Information System (INIS)
Shlewit, H.; AlIbrahim, M.
2009-01-01
Extraction, scrubbing and stripping of phosphoric acid from the Syrian wet-phosphoric acid was carried out using Micro-pilot plant of mixer settler type of 8 l/h capacity. Tributyl phosphate (TBP)/di-isopropyl ether (DIPE) in kerosene was used as extractant. Extraction and stripping equilibrium curves were evaluated. The number of extraction and stripping stages to achieve the convenient and feasible yield was determined. Detailed flow sheet was suggested for the proposed continuous process. Data obtained include useful information for the design of phosphoric acid extraction plant. The produced phosphoric acid was characterized using different analytical techniques. (author)
Techno-economic Analysis of Acid Gas Removal and Liquefaction for Pressurized LNG
Lee, S. H.; Seo, Y. K.; Chang, D. J.
2018-05-01
This study estimated the life cycle cost (LCC) of an acid gas removal and a liquefaction processes for Pressurized LNG (PLNG) production and compared the results with the cost of normal LNG production. PLNG is pressurized LNG that is liquefied at a higher pressure and temperature than normal LNG. Due to the high temperature, the energy for liquefaction is reduced. The allowable CO2 concentration in PLNG is increased up to 3 mol% when the product pressure 25 bar. An amine process with 35 wt% of diethanolamine (DEA) aqueous solution and a nitrogen expansion cycle were selected for the acid gas removal and the liquefaction processes, respectively. Two types of CO2 concentration in the feed gas were investigated to analyze their impacts on the acid gas removal unit. When the CO2 concentration was 5 mol%, the acid gas removal unit was required for both LNG and PLNG production. However, the acid gas removal unit was not necessary in PLNG when the concentration was 0.5 mol% and the pressure was higher than 15 bar. The results showed that the LCC of PLNG was reduced by almost 35% relative to that of LNG when the PLNG pressure was higher than 15 bar.
Lee, Jun; Kim, Dong-Min; Yun, Na Ra; Kim, Young Dae; Park, Chan Guk; Kim, Man Woo
2016-01-01
Scrub typhus is an infectious disease caused by Orientia tsutsugamushi-induced systemic vasculitis, but the involvement of the gastrointestinal tract and the endoscopic findings associated with scrub typhus are not well understood. We performed a prospective study and recommend performing esophagogastroduodenoscopy (EGD) for all possible scrub typhus patients, regardless of gastrointestinal symptoms. Gastrointestinal symptoms, endoscopic findings and clinical severity based on organ involvement and ICU admission were analyzed. Gastrointestinal symptoms occurred in up to 76.4% of scrub typhus patients. The major endoscopic findings were ulcers (43/127, 33.9%). Interestingly, 7.1% (9/127) of the patients presented with esophageal candidiasis. There was no correlation between the presence or absence of gastrointestinal symptoms and the endoscopic grade (P = 0.995). However, there was a positive correlation between the clinical severity and the endoscopic findings (P = 0.001). Sixty-three percent of the patients presented with erosion or ulcers on prospectively performed endoscopic evaluations, irrespective of gastrointestinal symptoms. Gastrointestinal symptoms did not reflect the need for endoscopy. Scrub typhus patients could have significant endoscopic abnormalities even in the absence of gastrointestinal symptoms.
The pathologic splenic rupture of a patient with scrub typhus: a case report
International Nuclear Information System (INIS)
Kim, Kum Rae; Park, Won Kyu; Chang, Jay Chun; Cho, Jae Ho; Kim, Jae Woon; Hwang, Mi Soo; Park, Bok Hwan
2008-01-01
A pathologic splenic rupture is rare, occurring primarily in a spleen affected by infective, hematological, and neoplastic disease. To the best of our knowledge, no prior reports of a pathologic splenic rupture due to scrub typhus exist. Intrasplenic pseudoaneurysms and focal infarctions are visible on an initial CT scan. Moreover, the spontaneous splenic rupture occurred a week later. We report a case of nontraumatic-splenic rupture in a patient with scrub typhus
The pathologic splenic rupture of a patient with scrub typhus: a case report
Energy Technology Data Exchange (ETDEWEB)
Kim, Kum Rae; Park, Won Kyu; Chang, Jay Chun; Cho, Jae Ho; Kim, Jae Woon; Hwang, Mi Soo; Park, Bok Hwan [College of Medicine, Yeungnam University, Daegu (Korea, Republic of)
2008-01-15
A pathologic splenic rupture is rare, occurring primarily in a spleen affected by infective, hematological, and neoplastic disease. To the best of our knowledge, no prior reports of a pathologic splenic rupture due to scrub typhus exist. Intrasplenic pseudoaneurysms and focal infarctions are visible on an initial CT scan. Moreover, the spontaneous splenic rupture occurred a week later. We report a case of nontraumatic-splenic rupture in a patient with scrub typhus.
Non-technical skills for scrub practitioners.
McClelland, Guy
2012-12-01
The non-technical skills of situational awareness and the formation of effective interpersonal relationships are essential to enhance surgical outcomes. However, most scrub practitioners demonstrate only tacit awareness of these skills and develop such qualities on an informal basis. Application of non-technical skills may be assessed formally, using a structured framework, to transform normative behaviour and to strengthen barriers against the latent threats that may result from fallible humans working in inadequate organisational systems.
Astrup, Elisabeth; Janardhanan, Jeshina; Otterdal, Kari; Ueland, Thor; Prakash, John A. J.; Lekva, Tove; Strand, Øystein A.; Abraham, O. C.; Thomas, Kurien; Damås, Jan Kristian; Mathews, Prasad; Mathai, Dilip; Aukrust, Pål; Varghese, George M.
2014-01-01
Background Scrub typhus, caused by Orientia tsutsugamushi, is endemic in the Asia-Pacific region. Mortality is high if untreated, and even with treatment as high as 10–20%, further knowledge of the immune response during scrub typhus is needed. The current study was aimed at comparing plasma levels of a variety of inflammatory mediators in scrub typhus patients and controls in South India in order to map the broader cytokine profile and their relation to disease severity and clinical outcome. Methodology/Principal Findings We examined plasma levels of several cytokines in scrub typhus patients (n = 129) compared to healthy controls (n = 31) and infectious disease controls (n = 31), both in the acute phase and after recovery, by multiplex technology and enzyme immunoassays. Scrub typhus patients were characterized by marked changes in the cytokine network during the acute phase, differing not only from healthy controls but also from infectious disease controls. While most of the inflammatory markers were raised in scrub typhus, platelet-derived mediators such as RANTES were markedly decreased, probably reflecting enhanced platelet activation. Some of the inflammatory markers, including various chemokines (e.g., interleukin-8, monocyte chemoattractant peptide-1 and macrophage inflammatory protein-1β) and downstream markers of inflammation (e.g., C-reactive protein and pentraxin-3), were also associated with disease severity and mortality during follow-up, with a particular strong association with interleukin-8. Conclusions/Significance Our findings suggest that scrub typhus is characterized by a certain cytokine profile that includes dysregulated levels of a wide range of mediators, and that this enhanced inflammation could contribute to disease severity and clinical outcome. PMID:24516677
Directory of Open Access Journals (Sweden)
Elisabeth Astrup
2014-02-01
Full Text Available BACKGROUND: Scrub typhus, caused by Orientia tsutsugamushi, is endemic in the Asia-Pacific region. Mortality is high if untreated, and even with treatment as high as 10-20%, further knowledge of the immune response during scrub typhus is needed. The current study was aimed at comparing plasma levels of a variety of inflammatory mediators in scrub typhus patients and controls in South India in order to map the broader cytokine profile and their relation to disease severity and clinical outcome. METHODOLOGY/PRINCIPAL FINDINGS: We examined plasma levels of several cytokines in scrub typhus patients (n = 129 compared to healthy controls (n = 31 and infectious disease controls (n = 31, both in the acute phase and after recovery, by multiplex technology and enzyme immunoassays. Scrub typhus patients were characterized by marked changes in the cytokine network during the acute phase, differing not only from healthy controls but also from infectious disease controls. While most of the inflammatory markers were raised in scrub typhus, platelet-derived mediators such as RANTES were markedly decreased, probably reflecting enhanced platelet activation. Some of the inflammatory markers, including various chemokines (e.g., interleukin-8, monocyte chemoattractant peptide-1 and macrophage inflammatory protein-1β and downstream markers of inflammation (e.g., C-reactive protein and pentraxin-3, were also associated with disease severity and mortality during follow-up, with a particular strong association with interleukin-8. CONCLUSIONS/SIGNIFICANCE: Our findings suggest that scrub typhus is characterized by a certain cytokine profile that includes dysregulated levels of a wide range of mediators, and that this enhanced inflammation could contribute to disease severity and clinical outcome.
Improvement of gas chromatographic analysis for organic acids and ...
African Journals Online (AJOL)
Yomi
2010-08-27
Aug 27, 2010 ... short retention time and fair recognition peak of the compounds were obtained under the ... GC for acid and solvent analysis from ABE fermentation ... FID was kept at 230°C. Nitrogen gas was used as a carrier gas at a.
Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.
Shivalli, Siddharudha
2016-05-12
Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.
Charoenphak, Sirima; Rattanawong, Pattara; Sungkanuparph, Somnuek
2017-01-01
Scrub typhus rarely presents with acute cholecystitis. We present 2 cases of scrub typhus with cholecystitis. The first patient is a 62 year old female who presented to the hospital with fever and body aches for 1 week and right upper quadrant abdominal pain for 3 days. She gave a history of an insect bite 2 weeks previously. She was diagnosed as having acute cholecystitis and underwent cholecystectomy. She continued with fever post-operatively and physical examination revealed an eschar. She had an immunofluorescence assay (IFA) performed that revealed a high IgM titer for Orientia tsutsugamushi. She was diagnosed as having scrub typhus, treated with doxycycline and she recovered completely. The second patient also presented to the hospital with a 1 week history of fever and upper quadrant abdominal pain. She was diagnosed with having cholecystitis. Her symptoms did not improve with intravenous antibiotics and further investigation revealed elevated titers for O. tsutsugamushi and Leptospira interrogans. She was diagnosed as having a co-infection of scrub typhus and leptospirosis and treated with doxycycline. She recovered completely. Patients from scrub typhus endemic regions who present with acute cholecystitis but do not respond to traditional treatment should be tested for scrub typhus and leptospirosis and should have a careful admission physical examination looking for eschar formation, since scrub typhus may present with acute cholecystitis.
Experimental study of influence characteristics of flue gas fly ash on acid dew point
Song, Jinhui; Li, Jiahu; Wang, Shuai; Yuan, Hui; Ren, Zhongqiang
2017-12-01
The long-term operation experience of a large number of utility boilers shows that the measured value of acid dew point is generally lower than estimated value. This is because the influence of CaO and MgO on acid dew point in flue gas fly ash is not considered in the estimation formula of acid dew point. On the basis of previous studies, the experimental device for acid dew point measurement was designed and constructed, and the acid dew point under different smoke conditions was measured. The results show that the CaO and MgO in the flue gas fly ash have an obvious influence on the acid dew point, and the content of the fly ash is negatively correlated with the temperature of acid dew point At the same time, the concentration of H2SO4 in flue gas is different, and the acid dew point of flue gas is different, and positively correlated with the acid dew point.
Mitchell, Lucy; Flin, Rhona; Yule, Steven; Mitchell, Janet; Coutts, Kathy; Youngson, George
2013-04-01
Adverse events still occur despite ongoing efforts to reduce harm to patients. Contributory factors to adverse events are often due to limitations in clinicians' non-technical skills (e.g. communication, situation awareness), rather than deficiencies in technical competence. We developed a behavioural rating system to provide a structured means for teaching and assessing scrub practitioners' (i.e. nurse, technician, operating department practitioner) non-technical skills. Psychologists facilitated focus groups (n = 4) with experienced scrub practitioners (n = 16; 4 in each group) to develop a preliminary taxonomy. Focus groups reviewed lists of non-technical-skill-related behaviours that were extracted from an interview study. The focus groups labelled skill categories and elements and also provided examples of good and poor behaviours for those skills. An expert panel (n = 2 psychologists; n = 1 expert nurse) then used an iterative process to individually and collaboratively review and refine those data to produce a prototype skills taxonomy. A preliminary taxonomy containing eight non-technical skill categories with 28 underlying elements was produced. The expert panel reduced this to three categories (situation awareness, communication and teamwork, task management), each with three underlying elements. The system was called the Scrub Practitioners' List of Intraoperative Non-Technical Skills system. A scoring system and a user handbook were also developed. A prototype behavioural rating system for scrub practitioners' non-technical skills was developed, to aid in teaching and providing formative assessment. This important aspect of performance is not currently explicitly addressed in any educational route to qualify as a scrub practitioner. © 2012 Blackwell Publishing Ltd.
Zhang, Luyan; Bi, Zhenwang; Kou, Zengqiang; Yang, Huili; Zhang, Aihua; Zhang, Shoufeng; Meng, Xiangpeng; Zheng, Li; Zhang, Meng; Yang, Hui; Zhao, Zhongtang
2015-03-01
Orientia tsutsugamushi, the causative agent of scrub typhus, is an obligate intracellular bacterium and characterized by dramatic genetic diversity. To elucidate the genotypes of O. tsutsugamushi populating in patients in Shandong Province, a new epidemic zone in China, we sequenced partial of the 56-kDa type-specific antigen gene (TSA) and identified the genotypes of 43 O. tsutsugamushi samples from human patients confirmed with scrub typhus from 2010 to 2013. All of the 43 sequences are in the same clade, 39 of them are in one branch and the other four sequences, nominated as SH1002, SH1306, SH1309, and SH1307 are in four separate branches. To clarify the clinical characterizations caused by Kawasaki-related genotypes, we studied the clinical profiles of these 43 scrub typhus patients. Most patients (88.1%) were farmers lived in rural areas. They presented with fever (100.0%), headache (79.1%), dizziness (32.6%), generalized myalgia (48.8%), fatigue (53.5%), anorexia (53.5%), facial flushing (23.3%), conjunctival congestion (11.6%), skin rashes (58.1%) and lymphadenopathy (23.3%). Eschar (97.7%) was quite common in patients, which provided doctors with a luminous clue for diagnosis of scrub typhus. Thrombocytopenia was seen in 23.1% of patients, and three patients (7.0%) had bronchopneumonia. There was no death report in Shandong Province during the study period. The present study provides beneficial data for clinical, serological, and molecular diagnosis of scrub typhus infections, and also provides foundations for subsequent studies. Copyright © 2015 Elsevier B.V. All rights reserved.
Lee, Min; Kim, June; Jo, Dae Sun
2017-04-01
Chloramphenicol and tetracycline are not recommended for treating scrub typhus in pediatric patients because of potential side effects, such as aplastic anemia or tooth discoloration. While clarithromycin has recently been used in adults, few reports have been published on its effects in pediatric patients. We report the clinical profiles of pediatric scrub typhus and the effects of clarithromycin on scrub typhus in children. We retrospectively analyzed medical records of 56 children with scrub typhus who were admitted between 2004 and 2013 to Chonbuk National University Hospital, Jeonju, Korea. Cases were divided into 3 groups based on thetreatment drug (chloramphenicol, azithromycin, and clarithromycin). We compared their clinical manifestations and laboratory findings. All patients exhibited fever and rash. Other common clinical manifestations were eschars (66%), lymphadenopathy (48%), upper respiratory symptoms (42%), abdominal pain (32%), and hepatosplenomegaly (14%). Elevated levels of C-reactive protein, erythrocyte sedimentation rates, aspartate transaminase, and alanine transaminase were detected in 95%, 96%, 84%, and 77% of patients, respectively. Additionally, decreased platelet and white blood cell levels were observed in 43% and 36% of patients, respectively. There were no statistical differences between the treatment groups in mean age ( P =0.114) or sex ( P =0.507). However, time to defervescence after the treatments differed significantly, being the shortest in the clarithromycin group ( P =0.019). All patients recovered without complications related to the disease or drugs. Clarithromycin was as effective as chloramphenicol and azithromycin in pediatric scrub typhus patients and may be used as a first-line treatment drug.
Scrub typhus causing neonatal hepatitis with acute liver failure-A case series.
Vajpayee, Shailja; Gupta, R K; Gupta, M L
2017-05-01
Neonatal hepatitis with acute liver failure due to varied etiology including various infections is reported in the past. Scrub typhus as a cause of neonatal hepatitis has rarely been reported in literature. A high index of clinical suspicion is required for early diagnosis and timely treatment. Severity and prognosis of the disease varies widely because several different strains of Orientia tsutsugamushi exist with different virulence. Delayed diagnosis can result in complication and significant morbidity and mortality. Here, we report three cases of neonatal hepatitis with acute liver failure caused by scrub typhus to increase awareness.
Determination of cutoff of ELISA and immunofluorescence assay for scrub typhus
Directory of Open Access Journals (Sweden)
Nitin Gupta
2016-01-01
Full Text Available Background: The most common method employed for diagnosis of scrub typhus is serology. It is widely known that demonstration of ≥4-fold rise in titers of antibody in paired sera is required for diagnosis. However, for guidance of initial treatment, there is a need for rapid diagnosis at the time of admission. Therefore, there is a need for standardized region specific cutoff titers at the time of admission. Materials and Methods: A total of 258 patients of all age groups with clinically suspected scrub typhus over a period of 24 months (October 2013-October 2015 were enrolled. Serum samples of these patients were subjected to immunofluorescent antibody (IFA for immunoglobulin M (IgM (Fuller Labs, USA with dilutions of 1:64, 1:128, 1:256, and 1:512. Serum samples of all 258 patients were subjected to IgM ELISA (Inbios Inc., USA. Any patient with response to antibiotics within 48 h accompanied by either presence of an eschar or positivity by polymerase chain reaction was taken as positive. Receiver operating characteristic (ROC curve was drawn to generate cutoff for these tests. Results: A total of 20 patients were diagnosed as cases of scrub typhus. The ROC curve analysis revealed a cutoff optical density value of 0.87 with sensitivity and specificity of 100% and 94.12%, respectively. ROC curve analysis of IFA revealed sensitivity and specificity of 100% and 93.5%, respectively at 1:64 dilution. Conclusion: Considering cost constraints, centers in and around New Delhi region can use the cutoffs we determined for the diagnosis of scrub typhus.
Early lessons from the Turner Valley Gas Plant: 'those smoke stacks got a lot of it'
Energy Technology Data Exchange (ETDEWEB)
Finch, D.
2002-06-01
Lessons learned (or not learned) since 1924 in Turner Valley in conjunction with the Royalite No. 4, Alberta's famous runaway well, is told. Initially the gas from this well contained 700 grains of hydrogen sulphide per 100 cubic feet of gas, delivered at such high pressure that no compression was necessary until 1938. Various technologies had been tried to scrub the gas, including a soda ash solution trickled down over a trellis of redwood grids in steel towers, absorbing the hydrogen sulphide. As early as 1925, the plant scrubbed 97 per cent of hydrogen sulphide from 45 million cubic feet of gas per day, making it the largest gas scrubbing plant in the world. However, the hydrogen sulphide scrubbed from the gas stream was being pumped out of twin 123-feet tall towers, and discharged into the atmosphere. At least one death is known to have been caused by the hydrogen sulphide, however, it is suspected that many more deaths have occurred on the ranches and homesteads located downwind from the plant, since people there breathed diluted hydrogen sulphide for 27 years. Royalite finally built a sulphur plant and began manufacturing elemental sulphur from the deadly gas processing byproduct. The issue of flaring has been a matter of serious concern in Alberta for a long time. Governments have made a variety of promises, usually prior to elections, to hold the industry to higher environmental standards, but such promises invariably last only a short time. Sooner or later every government appears to succumb to industry demands; after all, a large part of the provincial economy relies on the oil patch, and a significant portion of the provincial budget comes from direct and indirect taxation of the oil industry, the goose that lays the golden egg. To seriously deal with the issue of flaring, Albertans will need substantial changes in the management of the province.
Energy Technology Data Exchange (ETDEWEB)
Jo, Bang Sil; Lee, In Jae; Lee, Kwanseop [Dept. of Radiology, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)], E-mail: ijlee2003@medimail.co.kr; Im, Hyoung June [Dept. of Occupational Medicine, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)
2012-07-15
Background. Swine-origin influenza A (H1N1) virus (S-OIV) infection and scrub typhus, also known as tsutsugamushi disease can manifest as acute respiratory illnesses, particularly during the late fall or early winter, with similar radiographic findings, such as a predominance of ground-glass opacity (GGO). Purpose. To differentiate S-OIV infection from scrub typhus using high-resolution computed tomography (HRCT). Material and Methods. We retrospectively reviewed the HRCT findings of 14 patients with S-OIV infection and 10 patients with scrub typhus. We assessed the location, cross-sectional distribution, and the presence of a peribronchovascular distribution of GGO and consolidations on HRCT. We also assessed the presence of interlobular septal thickening, bronchial wall thickening, pneumothorax, pneumomediastinum, pleural effusion, and mediastinal or axillary lymph node enlargement. Results. Scrub typhus was more common than S-OIV in elderly patients (P < 0.001). The monthly incidences of S-OIV and scrub typhus infection reached a peak between October and November. About 86% of S-OIV patients and 80% of scrub typhus patients presented with GGO. About 67% of the GGO lesions in S-OIV had a peribronchovascular distribution, but this was absent in scrub typhus (P = 0.005). Consolidation (93% vs. 10%, P < 0.001) and bronchial wall thickening (43% vs. 0%, P = 0.024) were more frequent in S-OIV infection than scrub typhus. Interlobular septal thickening (90% vs. 36%, P = 0.013) and axillary lymphadenopathy (90% vs. 0%, P < 0.001) were more common in scrub typhus than S-OIV infection. Conclusion. There was considerable overlap in HRCT findings between S-OIV infection and scrub typhus. However, S-OIV showed a distinctive peribronchovascular distribution of GGO lesions. Consolidation and bronchial wall thickening were seen more frequently in S-OIV infection, whereas interlobular septal thickening and axillary lymphadenopathy were more common in scrub typhus. Thus, CT could
International Nuclear Information System (INIS)
Jo, Bang Sil; Lee, In Jae; Lee, Kwanseop; Im, Hyoung June
2012-01-01
Background. Swine-origin influenza A (H1N1) virus (S-OIV) infection and scrub typhus, also known as tsutsugamushi disease can manifest as acute respiratory illnesses, particularly during the late fall or early winter, with similar radiographic findings, such as a predominance of ground-glass opacity (GGO). Purpose. To differentiate S-OIV infection from scrub typhus using high-resolution computed tomography (HRCT). Material and Methods. We retrospectively reviewed the HRCT findings of 14 patients with S-OIV infection and 10 patients with scrub typhus. We assessed the location, cross-sectional distribution, and the presence of a peribronchovascular distribution of GGO and consolidations on HRCT. We also assessed the presence of interlobular septal thickening, bronchial wall thickening, pneumothorax, pneumomediastinum, pleural effusion, and mediastinal or axillary lymph node enlargement. Results. Scrub typhus was more common than S-OIV in elderly patients (P < 0.001). The monthly incidences of S-OIV and scrub typhus infection reached a peak between October and November. About 86% of S-OIV patients and 80% of scrub typhus patients presented with GGO. About 67% of the GGO lesions in S-OIV had a peribronchovascular distribution, but this was absent in scrub typhus (P = 0.005). Consolidation (93% vs. 10%, P < 0.001) and bronchial wall thickening (43% vs. 0%, P = 0.024) were more frequent in S-OIV infection than scrub typhus. Interlobular septal thickening (90% vs. 36%, P = 0.013) and axillary lymphadenopathy (90% vs. 0%, P < 0.001) were more common in scrub typhus than S-OIV infection. Conclusion. There was considerable overlap in HRCT findings between S-OIV infection and scrub typhus. However, S-OIV showed a distinctive peribronchovascular distribution of GGO lesions. Consolidation and bronchial wall thickening were seen more frequently in S-OIV infection, whereas interlobular septal thickening and axillary lymphadenopathy were more common in scrub typhus. Thus, CT could
A viable on-chip FPGA configuration memory scrubbing approach for CBM-ToF
Energy Technology Data Exchange (ETDEWEB)
Oancea, Andrei-Dumitru; Stuellein, Christian; Manz, Sebastian; Gebelein, Jano; Kebschull, Udo [Infrastruktur und Rechnersysteme in der Informationsverarbeitung (IRI), Goethe-Universitaet, Senckenberganlage 31, 60325 Frankfurt am Main (Germany); Collaboration: CBM-Collaboration
2015-07-01
The ToF Detector of the CBM Experiment will be equipped with FPGA-based read-out boards (ROBs). These ROBs will be operated in a radiation environment, and therefore need a mitigation mechanism against soft errors in the SRAM-based configuration memories of the FPGAs. The proposed approach combines intrinsic on-chip single upset correction with extrinsic selective frame scrubbing for multiple-bit upsets. The slow control is realized using the GBT-SCA, which is capable of handling interrupts. This enables the new approach of event-driven configuration frame correction. While conventional blind scrubbing leads to a continuous load on the control path, the selective frame scrubbing reduces this load to a minimum. For verification purposes, radiation tests with a proton beam were performed at COSY, Juelich. The occurred soft errors were classified into single and multiple- bit upsets, enabling an estimation of the rate at which extrinsic intervention is necessary.
Identification of Cyclopentenyl Fatty Acids by Gas Liquid Chromatography and Mass Spectrometry
DEFF Research Database (Denmark)
Shukla, V. K. S.; Abdel-Moety, E. M.; Larsen, Elfinn
1979-01-01
The straight chain fatty acids and the cyclopentenyl fatty acids present in the lipids of Hydnocarpus wightiana seeds were separated as their pyrrolidides by means of gas chromatography. A gas chromatography-mass spectrometry system confirmed the complete separation and permitted the identification...
Scrub typhus point-of-care testing: A systematic review and meta-analysis.
Directory of Open Access Journals (Sweden)
Kartika Saraswati
2018-03-01
Full Text Available Diagnosing scrub typhus clinically is difficult, hence laboratory tests play a very important role in diagnosis. As performing sophisticated laboratory tests in resource-limited settings is not feasible, accurate point-of-care testing (POCT for scrub typhus diagnosis would be invaluable for patient diagnosis and management. Here we summarise the existing evidence on the accuracy of scrub typhus POCTs to inform clinical practitioners in resource-limited settings of their diagnostic value.Studies on POCTs which can be feasibly deployed in primary health care or outpatient settings were included. Thirty-one studies were identified through PubMed and manual searches of reference lists. The quality of the studies was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2. About half (n = 14/31 of the included studies were of moderate quality. Meta-analysis showed the pooled sensitivity and specificity of commercially available immunochromatographic tests (ICTs were 66.0% (95% CI 0.37-0.86 and 92.0% (95% CI 0.83-0.97, respectively. There was a significant and high degree of heterogeneity between the studies (I2 value = 97.48%, 95% CI 96.71-98.24 for sensitivity and I2 value = 98.17%, 95% CI 97.67-98.67 for specificity. Significant heterogeneity was observed for total number of samples between studies (p = 0.01, study design (whether using case-control design or not, p = 0.01, blinding during index test interpretation (p = 0.02, and QUADAS-2 score (p = 0.01.There was significant heterogeneity between the scrub typhus POCT diagnostic accuracy studies examined. Overall, the commercially available scrub typhus ICTs demonstrated better performance when 'ruling in' the diagnosis. There is a need for standardised methods and reporting of diagnostic accuracy to decrease between-study heterogeneity and increase comparability among study results, as well as development of an affordable and accurate antigen-based POCT to tackle the
Renal Manifestation in Scrub Typhus during a Major Outbreak in Central Nepal.
Sedhain, A; Bhattarai, G R
2017-01-01
Renal involvement and acute kidney injury (AKI) are common clinical manifestations seen in scrub typhus, a vector-borne tropical disease. There are no data on renal manifestation in scrub typhus in Nepal. We conducted a prospective study to analyze the incidence, urinary abnormalities, course, severity, outcome, and the predictors of AKI in patients with scrub typhus during a major outbreak in Central Nepal. Total 1398 patients admitted with acute febrile illness were subjected for Scrub Typhus Detect™ Immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) test, of which 502 (35.90%) patients tested positive and were included in the study. Mean age of the patients was 30.37 ± 18.81 years (range, 1-79 years) with 26.29% in the pediatric age group. Female-to-male ratio was 1.26:1. Mean duration of fever was 6.8 ± 3.1 days. Mean IgM ELISA value for scrub typhus was 2.17 ± 1.70 without difference in AKI and non-AKI groups (2.17 ± 1.76 vs. 2.16 ± 1.62; P = 0.94). Urinary abnormalities were seen in 42.3% of patients. Mean serum creatinine was 1.37 ± 0.69 mg/dl with significant difference in two groups (1.85 ± 0.87 vs. 1.03 ± 0.17; P = 0.003). AKI was seen in 35.8% of patients with majority having Stage 1 AKI (68.3%) followed by Stage 2 (34.1%) and Stage 3 (1.2%). Hemodialysis was required for 3.94% of patients. In 54% of patients, AKI occurred in fifth and sixth day of fever. ICU admission was required for 18.73% of patients and 8.57% required ventilator support. Mortality rate was 1.79%, which was higher among patients with AKI (2.96% vs. 1.0%; P = 0.106). Multivariate analysis revealed that the presence of pneumonia, shock, and acute respiratory distress syndrome predicted the development of AKI.
Renal manifestation in scrub typhus during a major outbreak in central Nepal
Directory of Open Access Journals (Sweden)
A Sedhain
2017-01-01
Full Text Available Renal involvement and acute kidney injury (AKI are common clinical manifestations seen in scrub typhus, a vector-borne tropical disease. There are no data on renal manifestation in scrub typhus in Nepal. We conducted a prospective study to analyze the incidence, urinary abnormalities, course, severity, outcome, and the predictors of AKI in patients with scrub typhus during a major outbreak in Central Nepal. Total 1398 patients admitted with acute febrile illness were subjected for Scrub Typhus Detect™ Immunoglobulin M (IgM enzyme-linked immunosorbent assay (ELISA test, of which 502 (35.90% patients tested positive and were included in the study. Mean age of the patients was 30.37 ± 18.81 years (range, 1–79 years with 26.29% in the pediatric age group. Female-to-male ratio was 1.26:1. Mean duration of fever was 6.8 ± 3.1 days. Mean IgM ELISA value for scrub typhus was 2.17 ± 1.70 without difference in AKI and non-AKI groups (2.17 ± 1.76 vs. 2.16 ± 1.62; P = 0.94. Urinary abnormalities were seen in 42.3% of patients. Mean serum creatinine was 1.37 ± 0.69 mg/dl with significant difference in two groups (1.85 ± 0.87 vs. 1.03 ± 0.17; P = 0.003. AKI was seen in 35.8% of patients with majority having Stage 1 AKI (68.3% followed by Stage 2 (34.1% and Stage 3 (1.2%. Hemodialysis was required for 3.94% of patients. In 54% of patients, AKI occurred in fifth and sixth day of fever. ICU admission was required for 18.73% of patients and 8.57% required ventilator support. Mortality rate was 1.79%, which was higher among patients with AKI (2.96% vs. 1.0%; P = 0.106. Multivariate analysis revealed that the presence of pneumonia, shock, and acute respiratory distress syndrome predicted the development of AKI.
Clinical significance of NGAL and KIM-1 for acute kidney injury in patients with scrub typhus.
Sun, In O; Shin, Sung Hye; Cho, A Young; Yoon, Hyun Ju; Chang, Mi Yok; Lee, Kwang Young
2017-01-01
The aim of this study is to investigate the clinical significance of neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule-1 (KIM-1) for acute kidney injury (AKI) in patients with scrub typhus. From 2014 to 2015, 145 patients were diagnosed with scrub typhus. Of these, we enrolled 138 patients who were followed up until renal recovery or for at least 3 months. We measured serum and urine NGAL and KIM-1 levels and evaluated prognostic factors affecting scrub typhus-associated AKI. Of the 138 patients, 25 had scrub typhus-associated AKI. The incidence of AKI was 18.1%; of which 11.6%, 4.3%, and 2.2% were classified as risk, injury, and failure, respectively, according to RIFLE criteria. Compared with patients in the non-AKI group, patients in the AKI group were older and showed higher total leukocyte counts and hypoalbuminemia or one or more comorbidities such as hypertension (72% vs 33%, pscrub typhus-associated AKI.
Milder clinical manifestation of scrub typhus in Kinmen, Taiwan
Directory of Open Access Journals (Sweden)
Tung-Hung Su
2013-04-01
Conclusion: A unique summer-autumn type of scrub typhus with milder disease manifestations is identified in Kinmen. The younger patient population, rapid diagnosis, and prompt treatment may be associated with a shortened disease course and lead to a better outcome.
Usha, K; Kumar, E; Kalawat, Usha; Kumar, B Siddhartha; Chaudhury, A; Gopal, D V R Sai
2016-10-01
Scrub typhus is a vector-borne zoonotic infection caused by Orientiatsutsugamushi. Local epidemiology of the circulating serotypes of scrub typhus is not available from most parts of India. We conducted this study for the diagnosis of scrub typhus using IgM ELISA and to detect O. tsutsugamushi serotypes circulating in southern Andhra Pradesh, India. Samples were collected from patients clinically suspected to have scrub typhus and were subjected to IgM ELISA to measure IgM antibodies against O. tsutsugamushi. Nested polymerase chain reaction (PCR) was performed targeting strain-specific regions in ELISA-positive samples. Of a total of 663 samples, 258 (38.91%) were found to be positive by IgM ELISA. Serotypes could be detected in 230 (34.69%) samples only. Only two serotypes, Karp and Kawasaki, were found in the serum samples, with the former being predominant. The dual infection of Karp and Kawasaki serotypes was found in seven patients. Other serotypes such as Gilliam, Kuroki and Kato were not detected in the samples. The nested PCR products proved useful in presumptively identifying the endemic O. tsutsugamushi serotypes. The present study could be significant in understanding scrub typhus epidemiology in this region.
Energy Technology Data Exchange (ETDEWEB)
Bhown, A.S.; Alvarado, D.; Pakala, N. [and others
1994-12-01
The objective of this work is to develop a novel system for regenerable SO{sub 2} and NO{sub x} scrubbing of flue gas that focuses on (a) a novel method for regeneration of spent SO{sub 2} scrubbing liquor and (b) novel chemistry for reversible absorption of NO{sub x}. In addition, high efficiency hollow fiber contactors (HFC) are proposed as the devices for scrubbing the SO{sub 2} and NO{sub x} from the flue gas. The system will be designed to remove more than 95% of the SO{sub x} and more than 75% of the NO{sub x} from flue gases typical of pulverized coal-fired power plants at a cost that is at least 20% less than combined wet limestone scrubbing of SO{sub x} and selective catalytic reduction of NO{sub x}. In addition, the process will make only marketable byproducts, if any (no waste streams). The major cost item in existing technology is capital investment. Therefore, our approach is to reduce the capital cost by using high efficiency hollow fiber devices for absorbing and desorbing the SO{sub 2} and NO{sub x}. We will also introduce new process chemistry to minimize traditionally well-known problems with SO{sub 2} and NO{sub x} absorption and desorption. For example, we will extract the SO{sub 2} from the aqueous scrubbing liquor into an oligomer of dimethylaniline to avoid the problem of organic liquid losses in the regeneration of the organic liquid.
Activation of cytotoxic lymphocytes in patients with scrub typhus
de Fost, Maaike; Chierakul, Wirongrong; Pimda, Kriangsak; Dondorp, Arjen M.; White, Nicholas J.; van der Poll, Tom
2005-01-01
Thai patients with scrub typhus caused by the intracellular pathogen Orientia tsutsugamushi displayed elevated plasma concentrations of granzymes A and B, interferon-gamma (IFN)-gamma-inducible protein 10, and monokine induced by IFN-gamma. These data suggest that activation of cytotoxic lymphocytes
CLINICAL PROFILE, EPIDEMIOLOGY AND PROGNOSTIC FACTORS IN SCRUB TYPHUS
Directory of Open Access Journals (Sweden)
Priyadarshini B
2017-03-01
Full Text Available BACKGROUND Scrub typhus is an underdiagnosed disease, but potentially treatable, if diagnosis is made with high index of suspicion. Deaths are attributable to late presentation, delayed diagnosis and drug resistance. MATERIALS AND METHODS The study was an observational study of prospective design conducted in the Department of General Medicine, Government Medical College, Kozhikode, over a period of one year. History, physical examination and relevant lab investigations were done in 70 patients in the study. RESULTS Majority of patients were in working class. Most common physical finding was lymphadenopathy. Eschar was present in 46% of patients. Majority responded to doxycycline. Case fatality was 14.3%. CONCLUSION 1. Most cases occurred during cooler months of the year (Oct-Feb. 2. Fever and headache were the most common symptoms. 3. Lymphadenopathy was the most common sign followed by splenomegaly. 4. Eschar was present in 46% cases. 5. Leucocytosis was associated with poor prognosis and increased complication like meningoencephalitis. 6. Hypoalbuminaemia was associated with increased incidence of complications like myocarditis and encephalitis. 7. More than 2 times, elevation of transaminases was a poor prognostic marker. 8. Most common and important complication was Acute Kidney Injury (AKI. 9. Microangiopathic haemolysis could possibly be a contributory factor for high incidence of AKI associated with scrub typhus. 10. Rampant NSAID use is another contributory factor for high incidence of AKI associated with scrub typhus. 11. Resistance to doxycycline is emerging in our community and we should consider this possibility in cases with strong suspicion with no response to doxycycline.
Immunohistochemical Study of Scrub Typhus: A Report of Two Cases
Directory of Open Access Journals (Sweden)
Bo-Yuan Tseng
2008-02-01
Full Text Available Scrub typhus is a zoonotic disease caused by Orientia tsutsugamushi, which is transmitted by chiggers. The target cells of this rickettsia are poorly defined in humans. Immunohistochemical staining of tissue sections of patients with scrub typhus is helpful in investigating the target cells of this rickettsia in different organs. We studied two autopsy specimens by immunohistochemical staining using a specific antibody against O. tsutsugamushi. Rickettsiae were located in endothelial cells in all of the organs evaluated, namely heart, lung, brain, kidney, appendix and skin, within cardiac muscle cells and renal tubular epithelial cells, and in macrophages located in the lymph node, liver and spleen. In conclusion, O. tsutsugamushi may disseminate into multiple organs through endothelial cells and macrophages, resulting in the development of fatal complications.
Energy Technology Data Exchange (ETDEWEB)
NONE
1997-06-01
The Albany Interim Landfill Gas Extraction and Mobile Power System project served three research objectives: (1) determination of the general efficiency and radius of influence of horizontally placed landfill gas extraction conduits; (2) determination of cost and effectiveness of a hydrogen sulfide gas scrubber utilizing Enviro-Scrub{trademark} liquid reagent; and (3) construction and evaluation of a dual-fuel (landfill gas/diesel) 100 kW mobile power station. The horizontal gas extraction system was very successful; overall, gas recovery was high and the practical radius of influence of individual extractors was about 50 feet. The hydrogen sulfide scrubber was effective and its use appears feasible at typical hydrogen sulfide concentrations and gas flows. The dual-fuel mobile power station performed dependably and was able to deliver smooth power output under varying load and landfill gas fuel conditions.
Luquin, M; Lopez, F; Ausina, V
1989-01-01
The fatty acids, alcohols, and mycolic acids of 26 strains of Mycobacterium xenopi were studied by capillary gas chromatography and thin-layer chromatography. All strains contained alpha-, keto-, and omega-carboxymycolates. The primary mycolic acid cleavage product was hexacosanoic acid. The fatty acid patterns and, especially, the presence of 2-docosanol are characteristic markers of M. xenopi.
2010-10-01
..., without a permit, take scrub jays (Aphelocoma coerulescens) and Steller's jays (Cyanocitta stelleri) when... transported or sold or offered for sale except that, such transportation within the area, as may be necessary... the State agricultural department, college, or other public institution may requisition such scrub...
Fluidized bed incinerator development
International Nuclear Information System (INIS)
Ziegler, D.L.; Johnson, A.J.
1976-01-01
A fluidized bed incinerator is being developed for burning rad contaminated solid and liquid waste materials. In situ neutralization of acid gases by the bed material, catalytic afterburning, and gas filtration are used to produce a clean flue gas without the use of aqueous scrubbing
Zheng, L; Yang, H-L; Bi, Z-W; Kou, Z-Q; Zhang, L-Y; Zhang, A-H; Yang, L; Zhao, Z-T
2015-08-01
Tai'an, a famous cultural tourist district, is a new endemic foci of scrub typhus in northern China. Frequent reports of travel-acquired cases and absence of effective vaccine indicated a significant health problem of scrub typhus in Tai'an. Thus, descriptive epidemiological methods and spatial-temporal scan statistics were used to describe the epidemic characteristics and detect the significant clusters of the high incidence of scrub typhus at the town level in Tai'an. Results of descriptive epidemiological analysis showed a total of 490 cases were reported in Tai'an with the annual average incidence ranging from 0·48 to 2·27/100 000 during 2006-2013. Females, the elderly and farmers are the high-risk groups. Monthly changes of scrub typhus cases indicated an obvious epidemic period in autumn. Spatial-temporal distribution analysis, showed significant clusters of high incidence mainly located in eastern and northern Tai'an. Our study suggests that more effective, targeted measures for local residents should be implemented in the eastern and northern areas of Tai'an in autumn. Meanwhile, it may prove beneficial for health policy makers to advise travellers to take preventive measures in order to minimize the risk of infection of scrub typhus in Tai'an.
Lack, D. A.; Corbett, J. J.
2012-05-01
The International Maritime Organization (IMO) has moved to address the health and climate impact of the emissions from the combustion of low-quality residual fuels within the commercial shipping industry. Fuel sulfur content (FS) limits and an efficiency design index for future ships are examples of such IMO actions. The impacts of black carbon (BC) emissions from shipping are now under review by the IMO, with a particular focus on the potential impacts of future Arctic shipping. Recognizing that associating impacts with BC emissions requires both ambient and onboard observations, we provide recommendations for the measurement of BC. We also evaluate current insights regarding the effect of ship speed (engine load), fuel quality and exhaust gas scrubbing on BC emissions from ships. Observations demonstrate that BC emission factors (EFBC) increases 3 to 6 times at very low engine loads (engine load, even with reduced load fuel savings. If fleets were required to operate at lower maximum engine loads, presumably associated with reduced speeds, then engines could be re-tuned, which would reduce BC emissions. Ships operating in the Arctic are likely running at highly variable engine loads (25-100%) depending on ice conditions and ice breaking requirements. The ships operating at low load may be emitting up to 50% more BC than they would at their rated load. Such variable load conditions make it difficult to assess the likely emissions rate of BC. Current fuel sulfur regulations have the effect of reducing EFBC by an average of 30% and potentially up to 80% regardless of engine load; a removal rate similar to that of scrubbers. Uncertainties among current observations demonstrate there is a need for more information on a) the impact of fuel quality on EFBC using robust measurement methods and b) the efficacy of scrubbers for the removal of particulate matter by size and composition.
Takemoto, Yasuhiko; Suzuki, Yasuyuki; Horibe, Ryoko; Shimozawa, Nobuyuki; Wanders, Ronald J. A.; Kondo, Naomi
2003-01-01
Very long chain fatty acids (VLCFAs) and docosahexaenoic acid (DHA), phytanic acid, and plasmalogens are usually measured individually. A novel method for the screening of peroxisomal disorders, using gas chromatography/mass spectrometry (GC/MS), was developed. Saturated and unsaturated fatty acids,
Clinical profile and outcome of children with scrub typhus from Chennai, South India.
Ganesh, Ramaswamy; Suresh, Natarajan; Pratyusha, L L; Janakiraman, Lalitha; Manickam, Mani; Andal, A
2018-06-01
Scrub typhus is an acute febrile illness caused by Orientia tsutsugamushi. We prospectively studied the clinico-laboratory profile and outcome of 358 children aged 1 day to 18 years diagnosed with scrub typhus from Chennai, South India. All children (100%) had fever. Eschar was seen in 67%. All children were treated with oral doxycycline and those with complications were treated with intravenous chloramphenicol/azithromycin. Rapid defervescence (within 48 h) after initiation of doxycline was seen in 306 (85%) and 52 (14.5%) developed complications. Multivariate logistic regression analysis revealed that children who had an elevated aspartate amino transferase (> 120 IU/L) and the presence of thrombocytopenia (platelet count less than 1 lac cells/mm 3 ) at admission had high risk of developing complications. The overall mortality rate in this series was 0.8%. Our 4-year study highlights the clinico-laboratory profile of Scrub typhus in children from Chennai, South India. Early recognition and prompt treatment reduces the complication and mortality. What is Known: • Scrub typhus is endemic to tsutsugamushi triangle, a geographical triangle extending from northern Japan in the east to Pakistan and Afghanistan in the west and northern Australia in the south. • There is paucity of data regarding its clinico-laboratory profile in neonates as well as its predictors of outcome. What is New: • Children who had an elevated AST and the presence of thrombocytopenia at admission had high risk of developing complications.
Walker, R.J.
1988-06-16
A method of cleaning an exhaust gas containing particulates, SO/sub 2/ and NO/sub x/ is described. The method involves prescrubbing with water to remove HCl and most of the particulates, scrubbing with an aqueous absorbent containing a metal chelate and dissolved sulfite salt to remove NO/sub x/ and SO/sub 2/, and regenerating the absorbent solution by controlled heating, electrodialysis and carbonate salt addition. The NO/sub x/ is removed as N/sub 2/ gas or nitrogen sulfonate ions and the oxides of sulfur are removed as a valuable sulfate salt. 4 figs.
Amine-oxide hybrid materials for acid gas separations
Bollini, Praveen; Didas, Stephanie A.; Jones, Christopher W.
2011-01-01
Organic-inorganic hybrid materials based on porous silica materials functionalized with amine-containing organic species are emerging as an important class of materials for the adsorptive separation of acid gases from dilute gas streams
Determination of low chloride values in Rocky Flats scrub alloy solutions and other complex matrices
International Nuclear Information System (INIS)
Holcomb, H.P.
1985-01-01
A turbidimetric method, using silver chloride, has been developed to determine low ppM quantities of chloride in Rocky Flats scrub alloy (RFSA) dissolver solutions. This analytical technique has also been applied to other complex matrices such as process 50% caustic and neutralized Purex low heat liquid waste concentrate. A controlled-pH precipitation with NaOH, during which chloride remains in solution, is used to pretreat samples to minimize salt effects from acids, bases, and/or hydrolyzable ions. Control of pH with bromocresol purple indicator also provides a more consistent pH for silver chloride formation, aiding in turbidity reproducibility. Disodium ethylenediaminetetraacetic acid is employed to negate covalent bonding by Hg(II) with chloride. The average standard deviation was +-17% for turbidity reproducibility in simulated sample aliquots containing a total of 10 to 100 μg chloride. For actual RFSA samples, the relative standard deviation ranged from +-14% to +-26%, depending on initial chloride values. 8 refs., 1 fig
Self-Scrubbing Coal -- an integrated approach to clean air
Energy Technology Data Exchange (ETDEWEB)
Harrison, K.E. [Custom Coals Corp., Pittsburgh, PA (United States)
1997-12-31
Carefree Coal is coal cleaned in a proprietary dense-media cyclone circuit, using ultrafine magnetite slurries, to remove noncombustible material, including up to 90% of the pyritic sulfur. Deep cleaning alone, however, cannot produce a compliance fuel from coals with high organic sulfur contents. In these cases, Self-Scrubbing Coal will be produced. Self-Scrubbing Coal is produced in the same manner as Carefree Coal except that the finest fraction of product from the cleaning circuit is mixed with limestone-based additives and briquetted. The reduced ash content of the deeply-cleaned coal will permit the addition of relatively large amounts of sorbent without exceeding boiler ash specifications or overloading electrostatic precipitators. This additive reacts with sulfur dioxide (SO{sub 2}) during combustion of the coal to remove most of the remaining sulfur. Overall, sulfur reductions in the range of 80--90% are achieved. After nearly 5 years of research and development of a proprietary coal cleaning technology coupled with pilot-scale validation studies of this technology and pilot-scale combustion testing of Self-Scrubbing Coal, Custom Coals Corporation organized a team of experts to prepare a proposal in response to DOE`s Round IV Program Opportunity Notice for its Clean Coal Technology Program under Public Law 101-121 and Public Law 101-512. The main objective of the demonstration project is the production of a coal fuel that will result in up to 90% reduction in sulfur emissions from coal-fired boilers at a cost competitive advantage over other technologies designed to accomplish the same sulfur emissions and over naturally occurring low sulfur coals.
Thiga, Jacqueline W; Mutai, Beth K; Eyako, Wurapa K; Ng'ang'a, Zipporah; Jiang, Ju; Richards, Allen L; Waitumbi, John N
2015-04-01
Serum samples from patients in Kenya with febrile illnesses were screened for antibodies against bacteria that cause spotted fever, typhus, and scrub typhus. Seroprevalence was 10% for spotted fever group, typhus group, and 5% for scrub typhus group. Results should help clinicians expand their list of differential diagnoses for undifferentiated fevers.
Removal of an acid fume system contaminated with perchlorates located within hot cell
International Nuclear Information System (INIS)
Rosenberg, K.E.; Henslee, S.P.; Vroman, W.R.; Krsul, J.R.; Michelbacher, J.A.; Knighton, G.C.
1992-09-01
An add scrubbing system located within the confines of a highly radioactive hot cell at Argonne National Laboratory-West (ANL-W) was remotely removed. The acid scrubbing system was routinely used for the dissolution of irradiated reactor fuel samples and structural materials. Perchloric acid was one of the acids used in the dissolution process and remained in the system with its inherent risks. Personnel could not enter the hot cell to perform the dismantling of the acid scabbing system due to the high radiation field and the explosion potential associated with the perchlorates. A robot was designed and built at ANL-W and used to dismantle the system without the need for personnel entry into the hot cell. The robot was also used for size reduction of removed components and loading of the removed components into waste containers
Clinical Predictors of Multiple Organ Dysfunction Syndromes in Pediatric patients with Scrub Typhus.
Zhao, Dongying; Zhang, Yongjun; Yin, Zhaoqing; Zhao, Jing; Yang, Defeng; Zhou, Qun
2017-06-01
Scrub typhus can produce multiple organ dysfunction syndrome (MODS). Early recognition of the patients at risk of MODS would be helpful in providing timely management and reducing the mortality. In all, 449 children with scrub typhus were enrolled at three hospitals in Yunnan, China from January 2010 to January 2015. The patients' clinical status of organ system dysfunction was evaluated on the day of discharge from hospital by using standard criteria. The patients were classified into MODS present (64 cases, 14.3%) or MODS absent (385 cases, 85.7%). Multivariate logistic regression analyses revealed that the prognostic factors for MODS included skin rash (odds ratio, OR = 3.3, p = 0.037), time interval form treatment to defervescence (OR = 1.2, p = 0.035), hemoglobin (OR = 0.54, p = 0.041), platelet counts (OR = 0.06, p scrub typhus, our study provides clinicians with important information to improve the clinical monitoring and prognostication of MODS. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Analysis of Flue Gas Desulfurization (FGD) Processes for Potential Use on Army Coal-Fired Boilers
1980-09-01
SYSTEMS ALKALI- LIME/LIMESTONE AMMONIA SCRUBBING LIME OR LIMESTONE HC SCRUBBER INJECTION DRY SYSTEMS NAHCOLITE INJECTION BOILER INJECTION...requirements, and flexibility. Single-alkali flue gas scrubbers are gas-Hquid contacting devices that use the chemical reactions between soluble alkali... scrubbers are gas-liquid contacting devices that use the chemical reactions between limestone (mostly CaC03) and SOp to remove the oxides of sulfur from
Performance studies on hydrofluoric acid fumes scrubbing systems
Energy Technology Data Exchange (ETDEWEB)
Sarkar, S; Bhowmik, A; Bera, T K; Sridhar, H; Shanmugavelu, P; Muralidhara, H R [Rare Materials Project, Bhabha Atomic Research Centre, Mysore (India)
1994-06-01
Uranium hexafluoride gas is a major process medium for the production of nuclear fuels. Different types of scrubbers suitable for disposal of exhaust gases containing low concentration of HF/UF{sub 6} contaminants, treatment of contaminated air from the working environment of a plant and bulk quantity of HF/UF{sub 6} from storage vessels are described. 8 refs., 3 figs., 3 tabs.
Comparison of minocycline and azithromycin for the treatment of mild scrub typhus in northern China.
Zhao, Minxing; Wang, Ting; Yuan, Xiaoyu; Du, Weiming; Lin, Miaoxin; Shen, Yanbo
2016-09-01
Scrub typhus, caused by Orientia tsutsugamushi, has recently emerged in northern China where the disease had not been known to exist. Although doxycycline and azithromycin are the recommended agents for the treatment of scrub typhus, clinical responses depend both on the susceptibilities of various O. tsutsugamushi strains and the severity of the disease. A retrospective analysis was conducted on patients diagnosed with mild scrub typhus from August 2013 to January 2016 in the Affiliated Hospital of Nantong University, northern China. A total of 40 patients who received minocycline treatment and 34 patients who received azithromycin treatment were included in the analysis. All patients except one defervesced within 120 h after initiating antimicrobial therapy. Kaplan-Meier curves in association with log-rank test showed that the median time to defervescence was significantly shorter for the minocycline-treated group than the azithromycin-treated group (P = 0.003). There were no serious adverse events during treatment. No relapse occurred in either group during the 1-month follow-up period. In conclusion, both minocycline and azithromycin are effective and safe for the treatment of mild scrub typhus, but minocycline is more active than azithromycin against O. tsutsugamushi infection acquired in northern China. Copyright © 2016 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.
Extraction, scrub, and strip test results for the solvent transfer to salt waste processing facility
Energy Technology Data Exchange (ETDEWEB)
Peters, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
2017-09-07
The Savannah River National Laboratory (SRNL) prepared approximately 240 gallons of Caustic-Side Solvent Extraction (CSSX) solvent for use at the Salt Waste Processing Facility (SWPF). An Extraction, Scrub, and Strip (ESS) test was performed on a sample of the prepared solvent using a salt solution prepared by Parsons to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help qualify the solvent for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 15.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.
Directory of Open Access Journals (Sweden)
Nianyin Li
2015-09-01
Full Text Available How to effectively develop tight-gas carbonate reservoir and achieve high recovery is always a problem for the oil and gas industry. To solve this problem, domestic petroleum engineers use the combination of the successful experiences of North American shale gas pools development by stimulated reservoir volume (SRV fracturing with the research achievements of Chinese tight gas development by acid fracturing to propose volume acid fracturing technology for fractured tight-gas carbonate reservoir, which has achieved a good stimulation effect in the pilot tests. To determine what reservoir conditions are suitable to carry out volume acid fracturing, this paper firstly introduces volume acid fracturing technology by giving the stimulation mechanism and technical ideas, and initially analyzes the feasibility by the comparison of reservoir characteristics of shale gas with tight-gas carbonate. Then, this paper analyzes the validity and limitation of the volume acid fracturing technology via the analyses of control conditions for volume acid fracturing in reservoir fracturing performance, natural fracture, horizontal principal stress difference, orientation of in-situ stress and natural fracture, and gives the solution for the limitation. The study results show that the volume acid fracturing process can be used to greatly improve the flow environment of tight-gas carbonate reservoir and increase production; the incremental or stimulation response is closely related with reservoir fracturing performance, the degree of development of natural fracture, the small intersection angle between hydraulic fracture and natural fracture, the large horizontal principal stress difference is easy to form a narrow fracture zone, and it is disadvantageous to create fracture network, but the degradable fiber diversion technology may largely weaken the disadvantage. The practices indicate that the application of volume acid fracturing process to the tight-gas carbonate
Gas chromatography-vacuum ultraviolet spectroscopy for analysis of fatty acid methyl esters.
Fan, Hui; Smuts, Jonathan; Bai, Ling; Walsh, Phillip; Armstrong, Daniel W; Schug, Kevin A
2016-03-01
A new vacuum ultraviolet (VUV) detector for gas chromatography was recently developed and applied to fatty acid methyl ester (FAME) analysis. VUV detection features full spectral acquisition in a wavelength range of 115-240nm, where virtually all chemical species absorb. VUV absorption spectra of 37 FAMEs, including saturated, monounsaturated, and polyunsaturated types were recorded. Unsaturated FAMEs show significantly different gas phase absorption profiles than saturated ones, and these classes can be easily distinguished with the VUV detector. Another advantage includes differentiating cis/trans-isomeric FAMEs (e.g. oleic acid methyl ester and linoleic acid methyl ester isomers) and the ability to use VUV data analysis software for deconvolution of co-eluting signals. As a universal detector, VUV also provides high specificity, sensitivity, and a fast data acquisition rate, making it a powerful tool for fatty acid screening when combined with gas chromatography. The fatty acid profile of several food oil samples (olive, canola, vegetable, corn, sunflower and peanut oils) were analyzed in this study to demonstrate applicability to real world samples. Copyright © 2015 Elsevier Ltd. All rights reserved.
Polymeric Gas-Separation Membranes for Petroleum Refining
Directory of Open Access Journals (Sweden)
Yousef Alqaheem
2017-01-01
Full Text Available Polymeric gas-separation membranes were commercialized 30 years ago. The interest on these systems is increasing because of the simplicity of concept and low-energy consumption. In the refinery, gas separation is needed in many processes such as natural gas treatment, carbon dioxide capture, hydrogen purification, and hydrocarbons separations. In these processes, the membranes have proven to be a potential candidate to replace the current conventional methods of amine scrubbing, pressure swing adsorption, and cryogenic distillation. In this paper, applications of polymeric membranes in the refinery are discussed by reviewing current materials and commercialized units. Economical evaluation of these membranes in comparison to traditional processes is also indicated.
Uranium recovery from wet process phosphoric acid
International Nuclear Information System (INIS)
1980-01-01
In the field of metallurgy, specifically processes for recovering uranium from wet process phosphoric acid solution derived from the acidulation of uraniferous phosphate ores, problems of imbalance of ion exchange agents, contamination of recycled phosphoric acid with process organics and oxidizing agents, and loss and contamination of uranium product, are solved by removing organics from the raffinate after ion exchange conversion of uranium to uranous form and recovery thereof by ion exchange, and returning organics to the circuit to balance mono and disubstituted ester ion exchange agents; then oxidatively stripping uranium from the agent using hydrogen peroxide; then after ion exchange recovery of uranyl and scrubbing, stripping with sodium carbonate and acidifying the strip solution and using some of it for the scrubbing; regenerating the sodium loaded agent and recycling it to the uranous recovery step. Economic recovery of uranium as a by-product of phosphate fertilizer production is effected. (author)
Energy Technology Data Exchange (ETDEWEB)
Bucknor, M.; Farmer, M.; Grabaskas, D.
2017-06-26
The U.S. Nuclear Regulatory Commission has stated that mechanistic source term (MST) calculations are expected to be required as part of the advanced reactor licensing process. A recent study by Argonne National Laboratory has concluded that fission product scrubbing in sodium pools is an important aspect of an MST calculation for a sodium-cooled fast reactor (SFR). To model the phenomena associated with sodium pool scrubbing, a computational tool, developed as part of the Integral Fast Reactor (IFR) program, was utilized in an MST trial calculation. This tool was developed by applying classical theories of aerosol scrubbing to the decontamination of gases produced as a result of postulated fuel pin failures during an SFR accident scenario. The model currently considers aerosol capture by Brownian diffusion, inertial deposition, and gravitational sedimentation. The effects of sodium vapour condensation on aerosol scrubbing are also treated. This paper provides details of the individual scrubbing mechanisms utilized in the IFR code as well as results from a trial mechanistic source term assessment led by Argonne National Laboratory in 2016.
Use of face masks by non-scrubbed operating room staff: a randomized controlled trial.
Webster, Joan; Croger, Sarah; Lister, Carolyn; Doidge, Michelle; Terry, Michael J; Jones, Ian
2010-03-01
Ambiguity remains about the effectiveness of wearing surgical face masks. The purpose of this study was to assess the impact on surgical site infections (SSIs) when non-scrubbed operating room staff did not wear surgical face masks. Eight hundred twenty-seven participants undergoing elective or emergency obstetric, gynecological, general, orthopaedic, breast or urological surgery in an Australian tertiary hospital were enrolled. Complete follow-up data were available for 811 patients (98.1%). Operating room lists were randomly allocated to a 'Mask group' (all non-scrubbed staff wore a mask) or 'No Mask group' (none of the non-scrubbed staff wore masks). The primary end point, SSI was identified using in-patient surveillance; post discharge follow-up and chart reviews. The patient was followed for up to six weeks. Overall, 83 (10.2%) surgical site infections were recorded; 46/401 (11.5%) in the Masked group and 37/410 (9.0%) in the No Mask group; odds ratio (OR) 0.77 (95% confidence interval (CI) 0.49 to 1.21), p = 0.151. Independent risk factors for surgical site infection included: any pre-operative stay (adjusted odds ratio [aOR], 0.43 (95% CI, 0.20; 0.95), high BMI aOR, 0.38 (95% CI, 0.17; 0.87), and any previous surgical site infection aOR, 0.40 (95% CI, 0.17; 0.89). Surgical site infection rates did not increase when non-scrubbed operating room personnel did not wear a face mask.
Directory of Open Access Journals (Sweden)
Jong Yul Roh
Full Text Available To clarify the geographical distribution of scrub typhus vectors in Korea, a survey of larval trombiculid mites was conducted from 2005 to 2007 by collecting wild small mammals twice a year (spring and autumn at 24 sites nationwide. A total of 67,325 mites representing 4 genera and 14 species were collected from 783 trapped rodents, corresponding to a chigger index (number of chigger mites per rodent of 86.0. The predominant mite species were Leptotrombidium pallidum (52.6%, Leptotrombiduim scutellare (27.1%, Leptotrombidium palpale (8.2%, Leptotrombidium orientale (5.6%, and Neotrombicula tamiyai (1.7%. However, the proportions of L. scutellare in southern areas, including endemic provinces such as Jeollabuk-Do (34.3%, Jeollanam-Do (49.0%, and Gyeongsangnam-Do (88%, were relatively higher than in central Korean regions where L. pallidum was predominant. In autumn, the ratio of L. scutellare increased to 42% while the ratio of L. pallidum decreased. The geographical distribution map of the L. scutellare chigger index was identical to the incidence pattern of scrub typhus, whereas those of overall mites and L. pallidum showed no relationship with case incidence patterns. Distribution mapping analysis shows an identical geographical distribution of L. scutellare and epidemic incidence of scrub typhus in South Korea. L. pallidum could be another vector at all other parts of the Korean peninsula, including the eastern and northern regions that have a low level of scrub typhus incidence.
Scrub typhus masquerading as HELLP syndrome and puerperal sepsis in an asymptomatic malaria patient.
Karim, Habib Md Reazaul; Bhattacharyya, Prithwis; Kakati, Sonai Datta; Borah, Tridip Jyoti; Yunus, Md
2016-01-01
Scrub typhus and malaria can involve multiple organ systems and are notoriously known for varied presentations. However, clinical malaria or scrub typhus is unusual without fever. On the other hand, altered sensorium with or without fever, dehydration, hemorrhage and hemolysis may lead to low blood pressure. Presence of toxic granules and elevated band forms in such patients can even mimic sepsis. When such a patient is in the peripartum period, it creates a strong clinical dilemma for the physician especially in unbooked obstetric cases. We present such a case where a 26-year-old unbooked female presented on second postpartum day with severe anemia, altered sensorium, difficulty in breathing along with jaundice and gum bleeding without history of fever. Rapid diagnostic test for malaria was negative and no eschar was seen. These parameters suggested a diagnosis of HELLP (Hemolysis, Elevated Liver enzymes, Low Platelet) syndrome with or without puerperal sepsis. Subsequently she was diagnosed as having asymptomatic malaria and scrub typhus and responded to the treatment of it. The biochemical changes suggestive of HELLP syndrome also subsided. We present this case to emphasize the fact that mere absence of fever and eschar does not rule out scrub typhus. It should also be considered as a differential diagnosis in patients with symptoms and signs suggesting HELLP syndrome. Asymptomatic malaria can complicate case scenario towards puerperal sepsis by giving false toxic granules and band form in such situations.
Yang, Li-Ping; Liang, Si-Yuan; Wang, Xian-Jun; Li, Xiu-Jun; Wu, Yan-Ling; Ma, Wei
2015-01-01
Background Laiwu District is recognized as a hyper-endemic region for scrub typhus in Shandong Province, but the seriousness of this problem has been neglected in public health circles. Methodology/Principal Findings A disability-adjusted life years (DALYs) approach was adopted to measure the burden of scrub typhus in Laiwu, China during the period 2006 to 2012. A multiple seasonal autoregressive integrated moving average model (SARIMA) was used to identify the most suitable forecasting model for scrub typhus in Laiwu. Results showed that the disease burden of scrub typhus is increasing yearly in Laiwu, and which is higher in females than males. For both females and males, DALY rates were highest for the 60–69 age group. Of all the SARIMA models tested, the SARIMA(2,1,0)(0,1,0)12 model was the best fit for scrub typhus cases in Laiwu. Human infections occurred mainly in autumn with peaks in October. Conclusions/Significance Females, especially those of 60 to 69 years of age, were at highest risk of developing scrub typhus in Laiwu, China. The SARIMA (2,1,0)(0,1,0)12 model was the best fit forecasting model for scrub typhus in Laiwu, China. These data are useful for developing public health education and intervention programs to reduce disease. PMID:25569248
Directory of Open Access Journals (Sweden)
Min Jing-Si
2009-06-01
Full Text Available Abstract Background Before 1986, scrub typhus was only found endemic in southern China. Because human infections typically occur in the summer, it is called "summer type". During the autumn-winter period of 1986, a new type of scrub typhus was identified in Shandong and northern Jiangsu province of northern China. This newly recognized scrub typhus was subsequently reported in many areas of northern China and was then called "autumn-winter type". However, clinical characteristics of associated cases have not been reported. Methods From 1995 to 2006, all suspected scrub typhus cases in five township hospitals of Feixian county, Shandong province were enrolled. Indirect immunofluorescent assay (IFA was used as confirmatory serodiagnosis test. Polymerase chain reaction (PCR connected with restriction fragment length polymorphism (RFLP and sequence analyses were used for genotyping of O. tsutsugamushi DNAs. Clinical symptoms and demography of confirmed cases were analyzed. Results A total of 480 scrub typhus cases were confirmed. The cases occurred every year exclusively between September and December with a peak occurrence in October. The case numbers were relatively higher in 1995, 1996, 1997, and 2000 than in other years. 57.9% of cases were in the group aged 21–50. More cases occurred in male (56% than in female (44%. The predominant occupational group of the cases was farmers (85.0%. Farm work was reported the primary exposure to infection in 67.7% of cases. Fever, rash, and eschar were observed in 100.0%, 90.4%, and 88.5% of cases, respectively. Eschars formed frequently on or around umbilicus, abdomen areas, and front and back of waist (34.1% in both genders. Normal results were observed in 88.7% (WBC counts, 84.5% (PLT counts, and 89.7% (RBC counts of cases, respectively. Observations from the five hospitals were compared and no significant differences were found. Conclusion The autumn-winter type scrub typhus in northern China occurred
Scrub Typhus: A Clinico-Laboratory Differentiation of Children with and without Meningitis.
Bhat, Nowneet Kumar; Pandita, Neerul; Saini, Manju; Dhar, Minakshi; Ahmed, Sohaib; Shirazi, Nadia; Wasim, Sanober; Shirke, Rupali; Chandar, Vipan
2016-06-01
Neurological involvement in the form of meningitis or meningoencephalitis, although well documented in scrub typhus, has not been extensively studied in the pediatric population. We report the clinical and laboratory profile of 96 children with scrub typhus and compared those with and without meningitis. Twenty seven (28%) children had clinical and laboratory evidence of meningitis. The most frequent presenting features were fever (100%), meningeal signs (66.6%), nausea and vomiting (56.3%), seizures (55.5%) and altered sensorium (51.8%). The children with meningitis presented early and had significantly lower respiratory and renal impairments when compared with the non-meningitis group. Cerebrospinal fluid (CSF) analysis revealed elevated total leukocyte count (86.73 ± 94.50 cells/mm(3)), mononuclear pleocytosis (lymphocyte percentage of 76.85 ± 15.86), elevated proteins (108.33 ± 52.63 mg%) and normal CSF glucose (64.18 ± 15.92 mg%). We conclude that meningitis is a common and early complication of childhood scrub typhus. The CSF reveals a lymphocytic pleocytosis, raised proteins and a normal glucose level. These children respond promptly to appropriate antibiotics as do children without meningitis. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Scrub Typhus Leading to Acute Encephalitis Syndrome, Assam, India.
Khan, Siraj A; Bora, Trishna; Laskar, Basanta; Khan, Abdul M; Dutta, Prafulla
2017-01-01
To determine the contribution of Orientia tsutsugamushi, the agent of scrub typhus, as a cause of acute encephalitis syndrome (AES) in Assam, India, we conducted a retrospective study of hospital patients with symptoms of AES during 2013-2015. Our findings suggest that O. tsutsugamushi infection leads to AES and the resulting illness and death.
International Nuclear Information System (INIS)
Singh, D.; Croiset, E.; Douglas, P.L.; Douglas, M.A.
2003-01-01
The existing fleet of modern pulverised coal fired power plants represents an opportunity to achieve significant reductions in greenhouse gas emissions in the coming years providing that efficient and economical CO 2 capture technologies are available for retrofit. One option is to separate CO 2 from the products of combustion using conventional approaches such as amine scrubbing. An emerging alternative, commonly known as O 2 /CO 2 recycle combustion, involves burning the coal with oxygen in an atmosphere of recycled flue gas. Both approaches can be retrofitted to existing units, however they consume significant amounts of energy to capture, purify and compress the CO 2 for subsequent sequestration. This paper presents a techno-economic comparison of the performance of the two approaches. The comparison was developed using the commercial process simulation packages, Hysys and Aspen Plus. The results show that both processes are expensive options to capture CO 2 from coal power plants, however O 2 /CO 2 appears to be a more attractive retrofit than MEA scrubbing. The CO 2 capture cost for the MEA case is USD 53/ton of CO 2 avoided, which translates into 3.3 cents/kW h. For the O 2 /CO 2 case the CO 2 capture cost is lower at USD 35/ton of CO 2 avoided, which translates into 2.4 cents/kW h. These capture costs represent an approximate increase of 20-30% in current electricity prices
Wet Flue Gas Desulfurization Using a New O-Element Design Which Replaces the Venturi Scrubber
P. Lestinsky; D. Jecha; V. Brummer; P. Stehlik
2015-01-01
Scrubbing by a liquid spraying is one of the most effective processes used for removal of fine particles and soluble gas pollutants (such as SO2, HCl, HF) from the flue gas. There are many configurations of scrubbers designed to provide contact between the liquid and gas stream for effectively capturing particles or soluble gas pollutants, such as spray plates, packed bed towers, jet scrubbers, cyclones, vortex and venturi scrubbers. The primary function of venturi scrubb...
Kang, Seung-Ji; Jin, Hye-Mi; Won, Eun Jeong; Cho, Young-Nan; Jung, Hyun-Ju; Kwon, Yong-Soo; Kee, Hae Jin; Ju, Jae Kyun; Kim, Jung-Chul; Kim, Uh Jin; Jang, Hee-Chang; Jung, Sook-In; Kee, Seung-Jung; Park, Yong-Wook
2016-07-01
Mucosal-associated invariant T (MAIT) cells contribute to protection against certain microorganism infections. However, little is known about the role of MAIT cells in Orientia tsutsugamushi infection. Hence, the aims of this study were to examine the level and function of MAIT cells in patients with scrub typhus and to evaluate the clinical relevance of MAIT cell levels. Thirty-eight patients with scrub typhus and 53 health control subjects were enrolled in the study. The patients were further divided into subgroups according to disease severity. MAIT cell level and function in the peripheral blood were measured by flow cytometry. Circulating MAIT cell levels were found to be significantly reduced in scrub typhus patients. MAIT cell deficiency reflects a variety of clinical conditions. In particular, MAT cell levels reflect disease severity. MAIT cells in scrub typhus patients displayed impaired tumor necrosis factor (TNF)-α production, which was restored during the remission phase. In addition, the impaired production of TNF-α by MAIT cells was associated with elevated CD69 expression. This study shows that circulating MAIT cells are activated, numerically deficient, and functionally impaired in TNF-α production in patients with scrub typhus. These abnormalities possibly contribute to immune system dysregulation in scrub typhus infection.
Borkakoty, Biswajyoti; Jakharia, Aniruddha; Biswas, Dipankar; Mahanta, Jagadish
2016-01-01
Scrub typhus and leptospirosis are bacterial zoonotic disease causing high morbidity and mortality. The seasonal outbreak of pyrexia is common in Arunachal Pradesh (AP); many times the disease remains undiagnosed. An outbreak of pyrexia of unknown origin (PUO) occurred in Longding district of Arunachal Pradesh in 2013, with 108 deaths, which was investigated to elucidate the cause of illness. Blood samples from the affected region with acute pyrexia were collected, and screened for the malaria parasite, scrub typhus IgM and leptospira IgM. Scrub typhus IgM was reactive in 97% (30/31), and 25% (8/31) cases were co-infected with leptospira. Incidentally, scrub typhus reactive (67%) and leptospira co-infection (62.7%) were higher in females. Record of previous 3 years (2011-2013) from Longding, Community Health Centre showed an increase in indoor pyrexia cases by 2-fold or more during October and November. The present study is the first report of co-infection of scrub typhus with leptospirosis from Northeast India. Medical officers in this region should take scrub typhus and leptospirosis in their differential diagnosis of patients with PUO for early diagnosis and effective treatment.
Caspari, Lindsay; Epstein, Elizabeth; Blackman, Amy; Jin, Li; Kaufman, David A
2017-06-01
The use of catheter hub decontamination protocols is a common practice to reduce central line-associated bloodstream infections. However, few data exist on the most effective disinfection procedure prior to hub access accounting for human factors and time-dependent practices in real time in the clinical setting. An observational design with a multimodal intervention was used in this study in a neonatal intensive care unit. Direct observations on nurse compliance of scrub times with decontamination when accessing of venous catheter and feeding tube hubs were conducted during 3 phases: (1) baseline period prior to any interventions; (2) during an educational intervention phase; and (3) during a timer intervention period when using a timing device, either an actual timer or music button. Overall, both education and the timing device interventions increased the mean scrub time ± SD of venous catheter hubs. Mean baseline scrub times of 10 ± 5 seconds were lower compared with 23 ± 12 seconds after educational intervention (P music button use (P observed with scrub times of feeding tubes. Time-based infection control measures, such as scrubbing the hub, must be implemented with aids that qualify specific times to account for human factors, to ensure adherence to time-dependent measures aimed at decreasing nosocomial infections. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Directory of Open Access Journals (Sweden)
PS Mohseni- Meybodi
2008-04-01
Full Text Available Introduction: Many post-surgical wound infections in hospitals cause morbidity and morality of patients and these are usually transmitted via hands of surgical personnel. The aim of the present study was to detect and antibiogram the bacterial agents following scrubbing of hands of surgical personnel before operation. Methods: Hands of 134 personnels of operation room were swabbed following scrubbing with antiseptic Betadine solution. Swab samples were inoculated on selective and differential media such as blood ager, McConky and manitol salt agar(MSA. Following incubation of media at 37c° for 24hr, bacterial species were identified using differential related tests. The isolated species were than antibiogramed and the results together with other data was analysed by SPSS software program. Results: Of the total of 134 cases, 81(60.4% were male and 53(39.6% female. The mean scrub time for each person was (206.1+/-103.2 seconds; 6 to 60 seconds base change. Increasing time of scrub was significantly correlated with decreasing rate of bacteria (P=0.003, (R=-0.254. Contamination was present in 129(96.3% cases following scrubbing. Maximum contamination was observed in nails (92.5%. Average number of bacteria for each individual was between 0 and 159. 62.6% of isolated bacteria were non- staphylococci and 7.7% were S. aureus. Vancomycin and ceftizoxim were the most sensitive, while penicillin was the least sensitive antibiotic. Conclusion: Results revealed that hand contamination was more than the expected standard level. Therefore, regarding the critical task of surgical personnel, training of all operation room staff is highly recommended to minimize the rate of contamination.
A Review of Scrub Typhus (Orientia tsutsugamushi and Related Organisms: Then, Now, and Tomorrow
Directory of Open Access Journals (Sweden)
Alison Luce-Fedrow
2018-01-01
Full Text Available Scrub typhus and the rickettsial diseases represent some of the oldest recognized vector-transmitted diseases, fraught with a rich historical aspect, particularly as applied to military/wartime situations. The vectors of Orientia tsutsugamushi were once thought to be confined to an area designated as the Tsutsugamushi Triangle. However, recent reports of scrub typhus caused by Orientia species other than O. tsutsugamushi well beyond the limits of the Tsutsugamushi Triangle have triggered concerns about the worldwide presence of scrub typhus. It is not known whether the vectors of O. tsutsugamushi will be the same for the new Orientia species, and this should be a consideration during outbreak/surveillance investigations. Additionally, concerns surrounding the antibiotic resistance of O. tsutsugamushi have led to considerations for the amendment of treatment protocols, and the need for enhanced public health awareness in both the civilian and medical professional communities. In this review, we discuss the history, outbreaks, antibiotic resistance, and burgeoning genomic advances associated with one of the world’s oldest recognized vector-borne pathogens, O. tsutsugamushi.
Kawamura, O; Shimoyama, Y; Hosaka, H; Kuribayashi, S; Maeda, M; Nagoshi, A; Zai, H; Kusano, M
2011-05-01
Gastro-esophageal reflux disease (GERD)-related chronic cough (CC) may have multifactorial causes. To clarify the characteristics of esophagopharyngeal reflux (EPR) events in CC patients whose cough was apparently influenced by gastro-esophageal reflux (GER), we studied patients with CC clearly responding to full-dose proton pump inhibitor (PPI) therapy (CC patients). Ten CC patients, 10 GERD patients, and 10 healthy controls underwent 24-h ambulatory pharyngo-esophageal impedance and pH monitoring. Weakly acidic reflux was defined as a decrease of pH by >1 unit with a nadir pH >4. In six CC patients, monitoring was repeated after 8 weeks of PPI therapy. The number of each EPR event and the symptom association probability (SAP) were calculated. Symptoms were evaluated by a validated GERD symptom questionnaire. Weakly acidic gas EPR and swallowing-induced acidic/weakly acidic EPR only occurred in CC patients, and the numbers of such events was significantly higher in the CC group than in the other two groups (P pump inhibitor therapy abolished swallowing-induced acidic/weakly acidic EPR, reduced weakly acidic gas EPR, and improved symptoms (all P gas EPR and swallowing-induced acidic/weakly acidic EPR. A direct effect of acidic mist or liquid refluxing into the pharynx may contribute to chronic cough, while cough may also arise indirectly from reflux via a vago-vagal reflex in some patients. © 2011 Blackwell Publishing Ltd.
A case-control study of risk factors associated with scrub typhus infection in Beijing, China.
Directory of Open Access Journals (Sweden)
Yanning Lyu
Full Text Available To investigate the risk factors of scrub typhus infection in Beijing, China, a case-control study was carried out. Cases (n = 56 were defined as persons who were diagnosed by PCR and serological method within three years. Three neighborhood control subjects were selected by matching for age and occupation. Living at the edge of the village, living in the houses near grassland, vegetable field or ditch, house yard without cement floor, piling weeds in the house or yard, all of these were risk factors for scrub typhus infection. Working in vegetable fields and hilly areas, and harvesting in autumn posed the highest risks, with odds ratios (ORs and 95% confidence intervals (CIs of 3.7 (1.1-11.9, 8.2 (1.4-49.5, and 17.2 (5.1-57.9, respectively. These results would be useful for the establishment of a detail control strategy for scrub typhus infection in Beijing, China.
Chest radiographic findings of scrub typhus: an analysis of 160 cases occurred in Ulsan area
Energy Technology Data Exchange (ETDEWEB)
Kim, Ok Hwa; Oh, Dong Heon; Kim, Ki Sung; Woo, Je Ho; Kwon, Jung Hyeok [Dong Kang General Hospital, Ulsan (Korea, Republic of)
1993-03-15
Scrub typhus (Tsutsugamushi disease) is an acute febrile systemic illness caused by Rickettsia Tsutsugamushi that is transmitted to humans by the bite of larval-stage trombiculid mites (chiggers). The authors analyzed chest radiographic findings of scrub typhus in 160 patients in Ulsan area. One hundred and eight (67.5%) of 160 patients showed abnormal findings which included lung lesions in 108 patients (67.5%), cardiomegaly in 37 patients (23.1%), lymphadenopathy in 25 patients (15.6%) and pleural effusion in 11 patients (6.9%). Among the lung lesions, interstitial patterns were seen in 107 patients (66.9%), mostly fine or medium reticulonodular, and air-space patterns in 14 patients (8.8%) and combined interstitial and air-space patterns in 13 patients (8.1%). Sixty-four patients (40%) had combined chest radiographic findings. The typical chest radiographic findings of scrub typhus would be helpful in evaluation of the causes of acute febrile illness that occur during late fall in the endemic area.
Chest radiographic findings of scrub typhus: an analysis of 160 cases occurred in Ulsan area
International Nuclear Information System (INIS)
Kim, Ok Hwa; Oh, Dong Heon; Kim, Ki Sung; Woo, Je Ho; Kwon, Jung Hyeok
1993-01-01
Scrub typhus (Tsutsugamushi disease) is an acute febrile systemic illness caused by Rickettsia Tsutsugamushi that is transmitted to humans by the bite of larval-stage trombiculid mites (chiggers). The authors analyzed chest radiographic findings of scrub typhus in 160 patients in Ulsan area. One hundred and eight (67.5%) of 160 patients showed abnormal findings which included lung lesions in 108 patients (67.5%), cardiomegaly in 37 patients (23.1%), lymphadenopathy in 25 patients (15.6%) and pleural effusion in 11 patients (6.9%). Among the lung lesions, interstitial patterns were seen in 107 patients (66.9%), mostly fine or medium reticulonodular, and air-space patterns in 14 patients (8.8%) and combined interstitial and air-space patterns in 13 patients (8.1%). Sixty-four patients (40%) had combined chest radiographic findings. The typical chest radiographic findings of scrub typhus would be helpful in evaluation of the causes of acute febrile illness that occur during late fall in the endemic area
Paris, Daniel H; Stephan, Femke; Bulder, Ingrid; Wouters, Diana; van der Poll, Tom; Newton, Paul N; Day, Nicholas P J; Zeerleder, Sacha
2015-01-01
Cell-mediated immunity is essential in protection against rickettsial illnesses, but the role of neutrophils in these intracellular vasculotropic infections remains unclear. This study analyzed the plasma levels of nucleosomes, FSAP-activation (nucleosome-releasing factor), and neutrophil activation, as evidenced by neutrophil-elastase (ELA) complexes, in sympatric Lao patients with scrub typhus and murine typhus. In acute scrub typhus elevated nucleosome levels correlated with lower GCS scores, raised respiratory rate, jaundice and impaired liver function, whereas neutrophil activation correlated with fibrinolysis and high IL-8 plasma levels, a recently identified predictor of severe disease and mortality. Nucleosome and ELA complex levels were associated with a 4.8-fold and 4-fold increased risk of developing severe scrub typhus, beyond cut off values of 1,040 U/ml for nucleosomes and 275 U/ml for ELA complexes respectively. In murine typhus, nucleosome levels associated with pro-inflammatory cytokines and the duration of illness, while ELA complexes correlated strongly with inflammation markers, jaundice and increased respiratory rates. This study found strong correlations between circulating nucleosomes and neutrophil activation in patients with scrub typhus, but not murine typhus, providing indirect evidence that nucleosomes could originate from neutrophil extracellular trap (NET) degradation. High circulating plasma nucleosomes and ELA complexes represent independent risk factors for developing severe complications in scrub typhus. As nucleosomes and histones exposed on NETs are highly cytotoxic to endothelial cells and are strongly pro-coagulant, neutrophil-derived nucleosomes could contribute to vascular damage, the pro-coagulant state and exacerbation of disease in scrub typhus, thus indicating a detrimental role of neutrophil activation. The data suggest that increased neutrophil activation relates to disease progression and severe complications, and
Heterogeneous reactions and aerosol formation in flue gas cleaning by electron beam
International Nuclear Information System (INIS)
Baumann, W.; Jordan, S.; Leichsenring, C.H.; Maetzing, H.; Paur, H.R.; Schikarski, W.
1990-08-01
The electron beam dry scrubbing process is a simultaneous method for the removal of SO 2 and NO x from flue gas. By electron irradiation radicals (OH, O 2 H, O) are formed from the main flue gas components which oxidize NO x and SO 2 into the acids HNO 3 and H 2 SO 4 . These are then neutralized by the injection of NH 3 . A submicron aerosol consisting of ammonium salts is formed which is filtered from the offgas. The main pathways of the gas phase chemistry and product formation have been elucidated by experimental and theoretical studies. Back reactions which occur in the gas and the particle phase limit the energy efficiency of the process. By recirculation of irradiated gas into the reaction vessel (multiple irradiation) a significant improvement of removal yields was obtained. This enhancement of the energy efficiency requires the removal of products between the irradiation steps. Studies show that the material balance is complete. Deficits in the N and S balance of the process are due to the additional formation of molecular nitrogen and the deposition of ammonium sulfate in the ducts. Aerosol formation participates only with 30% in the material balance. The remaining 70% of the product are formed by surface reactions in the filter cake (40%) and in the ducts (30%). (orig.) With 38 figs., 29 tabs [de
Differences in agricultural activities related to incidence of scrub typhus between Korea and Japan
Directory of Open Access Journals (Sweden)
Chang-Jin Ma
2017-11-01
Full Text Available OBJECTIVES The purpose of this study was to establish a basis for improving or strengthening the preventive strategy against scrub typhus in Korea by comparing and analyzing the difference of prevention behaviors contributing to the occurrence of scrub typhus in Japan and Korea. METHODS The survey was carried out in Jeollabuk-do, which is a high risk and high incidence area, and Fukuoka Prefecture, which is a high risk and low incidence area. The study included 406 Korean farmers and 216 Japanese farmers. Data were collected through face-to-face surveys by interviewers who had completed standardized education. RESULTS Korean farmers have a higher percentage of agricultural working posture that involved contact with weeds than Japanese farmers (p<0.05. The frequency and proportion of weeding were lower in Korean farmers than in Japanese farmers (p<0.05. The level of knowledge about scrub typhus was significantly higher among Korean farmers than among Japanese farmers (p<0.05. Mostly, the behavior of agriculture work was more appropriate for Japanese farmers than for Korean farmers (p<0.05. The total average level of agricultural work was lower in Korea than in Japan, lower in men than women, and lower in part-time farmers than full-time farmers (p<0.05. CONCLUSIONS This study suggests that it is reasonable to develop and provide a program that can improve the level of preventive behavior taking into consideration the characteristics of the subject in order to reduce the incidence of diseases in high-risk areas for scrub typhus.
Gas-Phase IR Spectroscopy of Deprotonated Amino Acids
Oomens, J.; Steill, J. D.; Redlich, B.
2009-01-01
Gas-phase infrared multiple photon dissociation (IRMPD) spectra have been recorded for the conjugate bases of a series of amino acids (Asp, Cys, Glu, Phe, Set, Trp, Tyr). The spectra are dominated by strong symmetric and antisymmetric carboxylate stretching modes around 1300 and 1600 cm(-1),
Gas chromatography of alkylphosphonic and dialkylphosphinic acids
International Nuclear Information System (INIS)
Gasco, L.; Barrera, R.; Ramirez, A.; Martin Munoz, N.
1978-01-01
After carrying out an optimization study on the separation conditions for the TMS-derivatives, of the hexyl-, cyclohexyl-, heptyl-, and octyl-phosphonic acids; dihexyl-, dicyclohexyl-, heptyl-, and octyl-phosphinic acids, and dioctylphosphine oxide, their retention indices (I) at two temperatures and on the 0V-1 and 0V-17 stationary phase were determined. Correlations between I and molecular structure were established. Calibration factors of these compounds in the flame ionization detector were studied, and the results analized taking into account the variables afecting the quantitative results. These results were unbiased but they had a lower precission than usually achieveble in gas chromatography. (author)
Scrub typhus, a disease with increasing threat in Guangdong, China.
Directory of Open Access Journals (Sweden)
Wu De
Full Text Available There has been a rapid increase in the number of scrub typhus cases in Guangdong Province, China. For this reason, an epidemiologic study was conducted to understand the characteristics of scrub typhus epidemics in Guangdong. From 2006 to 2013, the incidence of human cases increased from 0.4321 to 3.5917 per 100,000 with a bimodal peak in human cases typically occurring between May and November. To detect the prevalence of Orientia tsutsugamushi among suspected human cases and rodents, we performed ELISA tests of IgM/IgG and nested PCR tests on 59 whole blood samples from the suspected cases and 112 spleen samples from the rodents. Suspected cases tested positive for anti-O. tsutsugamushi IgM and IgG 66.1% (39/59 and 50.8% (30/59 of the time, respectively. Additionally, 20.3% (12/59 of blood samples and 13.4% (15/112 of spleen samples were positive for PCR. Phylogenetic analysis revealed that there were four definable clusters among the 27 nucleotide sequences of the 56-kDa antigen genes: 44.4% Karp (12/27, 25.9% Kato (7/27, 22.2% Gilliam (6/27 and 7.4% TA763 (2/27. We concluded many suspected cases may result in diagnostic errors; therefore, it is necessary to perform laboratory tests on suspected cases in hospitals. The high infection rate of O. tsutsugamushi among the limited rodents tested suggested that further rodent sampling throughout the province is necessary to further define high-risk areas. Furthermore, the multiple co-circulating genotypes of O. tsutsugamushi play a key role in the pervasiveness of scrub typhus in the Guangdong area.
International Nuclear Information System (INIS)
Holladay, D.W.
1979-01-01
Emphasis was focused on the operating parameters that most strongly affected the optimization of the processes used to treat actual process or feed streams which simulated actual compositions occurring at nuclear facilities. These parameters included gas superficial velocity, temperature, types of organic and inorganic contaminants, relative humidity, iodine feed-gas concentration, iodine species, column design (for both acid-scrub and solid sorbent-based processes), sorbent particle size, run time, intense radiation (solid sorbents only), and scrub-acid concentration. The most promising acid-scrub process for removal of iodine species from off-gases appears to be Iodox. The most promising solid sorbent for removal of iodine species from off-gases is the West German Ag-KTB--AgNO 3 -impregnated amorphous silicic acid. The tandem silver mordenite--lead mordenite sorbent system is also quite attractive. Only a limited number of processes have thus far been studied for removal of iodine species from low-level liquid waste streams. The most extensive successful operating experience has been obtained with anion exchange resins utilized at nuclear power reactors. Bench-scale engineering tests have indicated that the best process for removal of all types of iodine species from liquid waste streams may be treatment on a packed bed containing a mixture of sorbents with affinity for both elemental and anionic species of iodine. 154 references, 7 figures, 21 tables
Electron beam treatment technology for exhaust gas for preventing acid rain
International Nuclear Information System (INIS)
Aoki, Shinji
1990-01-01
Recently, accompanying the increase of the use of fossil fuel, the damage due to acid rain such as withering of trees and extinction of fishes and shells has occurred worldwide, and it has become a serious problem. The sulfur oxides and nitrogen oxides contained in exhaust gas are oxidized by the action of sunbeam to become sulfuric acid and nitric acid mists, which fall in the form of rain. Acid rain is closely related to the use of the coal containing high sulfur, and it hinders the use of coal which is rich energy source. In order to simplify the processing system for boiler exhaust gas and to reduce waste water and wastes, Ebara Corp. developed the dry simultaneous desulfurizing and denitrating technology utilizing electron beam in cooperation with Japan Atomic Energy Research Institute. The flow chart of the system applied to the exhaust gas treatment in a coal-fired thermal power station is shown. The mechanism of desulfurization and denitration, and the features of this system are described. The demonstration plant was constructed in a coal-fired thermal power station in Indianapolis, Indiana, USA, and the trial operation was completed in July, 1987. The test results are reported. (K.I.)
Clinical significance of NGAL and KIM-1 for acute kidney injury in patients with scrub typhus.
Directory of Open Access Journals (Sweden)
In O Sun
Full Text Available The aim of this study is to investigate the clinical significance of neutrophil gelatinase-associated lipocalin (NGAL and kidney injury molecule-1 (KIM-1 for acute kidney injury (AKI in patients with scrub typhus.From 2014 to 2015, 145 patients were diagnosed with scrub typhus. Of these, we enrolled 138 patients who were followed up until renal recovery or for at least 3 months. We measured serum and urine NGAL and KIM-1 levels and evaluated prognostic factors affecting scrub typhus-associated AKI.Of the 138 patients, 25 had scrub typhus-associated AKI. The incidence of AKI was 18.1%; of which 11.6%, 4.3%, and 2.2% were classified as risk, injury, and failure, respectively, according to RIFLE criteria. Compared with patients in the non-AKI group, patients in the AKI group were older and showed higher total leukocyte counts and hypoalbuminemia or one or more comorbidities such as hypertension (72% vs 33%, p<0.01, diabetes (40% vs 14%, p<0.01, or chronic kidney disease (32% vs 1%, p<0.01. In addition, serum NGAL values (404± 269 vs 116± 78 ng/mL, P<0.001, KIM-1 values (0.80± 0.52 vs 0.33± 0.68 ng/mL, P<0.001, urine NGAL/creatinine values (371± 672 vs 27± 39 ng/mg, P<0.001 and urine KIM-1/creatinine values (4.04± 2.43 vs 2.38± 1.89 ng/mg, P<0.001 were higher in the AKI group than in the non-AKI group. By multivariate logistic regression, serum NGAL and the presence of chronic kidney disease were significant predictors of AKI.Serum NGAL might be an additive predictor for scrub typhus-associated AKI.
Clinical profile and improving mortality trend of scrub typhus in South India.
Varghese, George M; Trowbridge, Paul; Janardhanan, Jeshina; Thomas, Kurien; Peter, John V; Mathews, Prasad; Abraham, Ooriapadickal C; Kavitha, M L
2014-06-01
Scrub typhus, a bacterial zoonosis caused by Orientia tsutsugamushi, may cause multiorgan dysfunction syndrome (MODS) and is associated with significant mortality. This study was undertaken to document the clinical and laboratory manifestations and complications and to study time trends and factors associated with mortality in patients with scrub typhus infection. This retrospective study, done at a university teaching hospital, included 623 patients admitted between 2005 and 2010 with scrub typhus. The diagnosis was established by a positive IgM ELISA and/or pathognomonic eschar with PCR confirmation where feasible. The clinical and laboratory profile, course in hospital, and outcome were documented. Factors associated with mortality were analyzed using multivariate logistic regression analysis. The most common presenting symptoms were fever (100%), nausea/vomiting (54%), shortness of breath (49%), headache (46%), cough (38%), and altered sensorium (26%). An eschar was present in 43.5% of patients. Common laboratory findings included elevated transaminases (87%), thrombocytopenia (79%), and leukocytosis (46%). MODS was seen in 34% of patients. The overall case-fatality rate was 9.0%. Features of acute lung injury were observed in 33.7%, and 29.5% required ventilatory support. On multivariate analysis, shock requiring vasoactive agents (relative risk (RR) 10.5, 95% confidence interval (CI) 4.2-25.7, p<0.001), central nervous system (CNS) dysfunction (RR 5.1, 95% CI 2.4-10.7, p<0.001), and renal failure (RR 3.6, 95% CI 1.7-7.5, p=0.001) were independent predictors of mortality. Over 4 years, a decreasing trend was observed in the mortality rate. Scrub typhus can manifest with potentially life-threatening complications such as lung injury, shock, and meningoencephalitis. MODS occurred in a third of our patients. The overall case-fatality rate was 9%, with shock, renal failure, and CNS associated with a higher mortality. Copyright © 2014 The Authors. Published by
Thermodynamic properties of acid gases in mixture with natural gas and water
Tang, X.
2011-01-01
The reliable removal of acid gas components, such as carbon dioxide (CO2) and hydrogen sulfide (H2S) from natural gas is an important technical challenge. Crude oil and hydrocarbon gas streams may contain high levels of CO2 and/or H2S as contaminants. It is desirable to prevent any contaminant to
Effect of oxygen enrichment in air on acid gas combustion under Claus conditions
Ibrahim, Salisu
2013-09-01
Results are presented to examine the combustion of acid gas (H2S and CO2) in hydrogen-fueled flames using a mixture of oxygen and nitrogen under Claus conditions (Φ = 3). Specifically the effect of oxygen enrichment in the above flames is examined. The compositions of acid gas examined are100% H2S and 50% H2S/50% CO2 with different percentages of oxygen enrichment (0%, 19.3% and 69.3%) in the oxygen/nitrogen mixtures. The results revealed that combustion of acid gas formed SO2 wherein the mole fraction of SO2 increased to an asymptotic value at all the oxygen concentrations examined. In addition, increase in oxygen enrichment of the air resulted in increased amounts of SO2 rather than the formation of more desirable elemental sulfur. In case of 50% H2S/50% CO2 acid gas, carbon monoxide mole fraction increased with oxygen enrichment which is an indicator to the availability of additional amounts of oxygen into the reaction pool. This gas mixture resulted in the formation of other sulfurous–carbonaceous compounds (COS and CS2) due to the presence of carbon monoxide. The results showed that the rate of COS formation increased with oxygen enrichment due to the availability of higher amounts of CO while that of CS2 reduced. The global reactions responsible for this observed phenomenon are presented.
Estimation of brassylic acid by gas chromatography-mass spectrometry
Energy Technology Data Exchange (ETDEWEB)
Mohammed J. Nasrullah, Erica N. Pfarr, Pooja Thapliyal, Nicholas S. Dusek, Kristofer L. Schiele, Christy Gallagher-Lein, and James A. Bahr
2010-10-29
The main focus of this work is to estimate Brassylic Acid (BA) using gas chromatography-mass spectrometry (GC-MS). BA is a product obtained from the oxidative cleavage of Erucic Acid (EA). BA has various applications for making nylons and high performance polymers. BA is a 13 carbon compound with two carboxylic acid functional groups at the terminal end. BA has a long hydrocarbon chain that makes the molecule less sensitive to some of the characterization techniques. Although BA can be characterized by NMR, both the starting material (EA) and products BA and nonanoic acid (NA) have peaks at similar {delta}, ppm values. Hence it becomes difficult for the quick estimation of BA during its synthesis.
Energy Technology Data Exchange (ETDEWEB)
Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
2017-08-01
An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.
Evaluation of a Zirconium Recycle Scrubber System
Energy Technology Data Exchange (ETDEWEB)
Spencer, Barry B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bruffey, Stephanie H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
2017-04-01
A hot-cell demonstration of the zirconium recycle process is planned as part of the Materials Recovery and Waste Forms Development (MRWFD) campaign. The process treats Zircaloy® cladding recovered from used nuclear fuel with chlorine gas to recover the zirconium as volatile ZrCl4. This releases radioactive tritium trapped in the alloy, converting it to volatile tritium chloride (TCl). To meet regulatory requirements governing radioactive emissions from nuclear fuel treatment operations, the capture and retention of a portion of this TCl may be required prior to discharge of the off-gas stream to the environment. In addition to demonstrating tritium removal from a synthetic zirconium recycle off-gas stream, the recovery and quantification of tritium may refine estimates of the amount of tritium present in the Zircaloy cladding of used nuclear fuel. To support these objectives, a bubbler-type scrubber was fabricated to remove the TCl from the zirconium recycle off-gas stream. The scrubber was fabricated from glass and polymer components that are resistant to chlorine and hydrochloric acid solutions. Because of concerns that the scrubber efficiency is not quantitative, tests were performed using DCl as a stand-in to experimentally measure the scrubbing efficiency of this unit. Scrubbing efficiency was ~108% ± 3% with water as the scrubber solution. Variations were noted when 1 M NaOH scrub solution was used, values ranged from 64% to 130%. The reason for the variations is not known. It is recommended that the equipment be operated with water as the scrubbing solution. Scrubbing efficiency is estimated at 100%.
Ittyachen, Abraham M; Abraham, Saramma P; Krishnamoorthy, Smitha; Vijayan, Anuroopa; Kokkat, Jayamohan
2017-10-06
Scrub typhus is an acute infectious illness caused by Orientia tsutsugamushi. It is endemic to a part of the world known as the "tsutsugamushi triangle". Humans are accidental hosts in this zoonotic disease. About a third of patients admitted with scrub typhus have evidence of multi-organ dysfunction. Multi-organ dysfunction secondary to scrub typhus carries a high mortality rate. We report a 65-year old lady who was admitted in a Tertiary Care Center in the state of Kerala in India, with 7 day history of fever, myalgia and reduced urine output. Head to foot examination revealed the presence of an eschar on her chest. One week prior to the onset of her illness she had gone trekking through a hilly forest area. She was clinically suspected to have scrub typhus, which was later confirmed with laboratory tests. She developed multi-organ dysfunction syndrome secondary to this illness. Though there was an improvement in the multi-organ dysfunction, thrombocytopenia alone failed to improve. Bone marrow study was done which was suggestive of immune thrombocytopenia. Patient was given a course of steroids with which the thrombocytopenia improved. Failure of platelet count to normalize even after there has been a general improvement of other markers of multi-organ dysfunction in scrub typhus should prompt the clinician to consider other potential causes of thrombocytopenia. An unusual finding as this calls for further research to understand the molecular mechanisms behind such an event. Further, considering the close similarity in clinical presentation of several tropical illnesses, meticulous history taking and a detailed physical examination needs to be emphasized.
International Nuclear Information System (INIS)
Zahariah Ismail; Mohd Fadlly Jumadi; Nurdiyana Mohamed Johari
2015-01-01
Treated guava scrub granules (GSG) as an exfoliating agent were obtained from the decanter waste at Sime Darby Food and Beverages, Sungai Wangi, Perak (SDFB). The treated GSG and tocotrienol were the main active ingredients incorporated in a basic formulation containing 87 % palm-based derivatives. Guava body scrub (GBS) and guava facial scrub (GFS) lotions were developed at skin pH 5.5 and pH 5.6 respectively. Both products were found to be stable for three years due to the liquid crystalline structure in the emulsion system , having small particle size (490 nm and 880 nm) and high zeta potential values (-54 mv and -39 mv). The rheological properties showed that the GBS lotion had a viscosity at 900 Pas and a yield value at 98 Pa, whereas the GFS lotion 60 Pas and 6 Pa viscosity and yield values respectively. The formulations were designed to be soft and flowable, with the firmness force indicated at 111 g and 66 g for GBS lotion and GFS lotion respectively. Efficacy testing on 20 healthy subjects showed a significant decrease of 21 % and 22 % in skin sebum removal for GBS lotion and GFS lotion respectively. (author)
Differences in agricultural activities related to incidence of scrub typhus between Korea and Japan.
Ma, Chang-Jin; Oh, Gyung-Jae; Kang, Gong-Unn; Lee, Jeong Mi; Lee, Da-Un; Nam, Hae-Sung; Ryu, So Yeon; Lee, Young-Hoon
2017-01-01
The purpose of this study was to establish a basis for improving or strengthening the preventive strategy against scrub typhus in Korea by comparing and analyzing the difference of prevention behaviors contributing to the occurrence of scrub typhus in Japan and Korea. The survey was carried out in Jeollabuk-do, which is a high risk and high incidence area, and Fukuoka Prefecture, which is a high risk and low incidence area. The study included 406 Korean farmers and 216 Japanese farmers. Data were collected through face-to-face surveys by interviewers who had completed standardized education. Korean farmers have a higher percentage of agricultural working posture that involved contact with weeds than Japanese farmers (pwork was more appropriate for Japanese farmers than for Korean farmers (pwork was lower in Korea than in Japan, lower in men than women, and lower in part-time farmers than full-time farmers (p<0.05). This study suggests that it is reasonable to develop and provide a program that can improve the level of preventive behavior taking into consideration the characteristics of the subject in order to reduce the incidence of diseases in high-risk areas for scrub typhus.
Seismic modeling of acid-gas injection in a deep saline reservoir
Energy Technology Data Exchange (ETDEWEB)
Ursenbach, C.P.; Lawton, D.C. [Calgary Univ., AB (Canada). Dept. of Geoscience, Consortium for Research in Elastic Wave Exploration Seismology
2008-07-01
Carbon dioxide (CO{sub 2}) and hydrogen sulfide (H{sub 2}S) are common byproducts of the energy industry. As such, remediation studies are underway to determine the feasibility of sequestering these byproducts in subsurface reservoirs, including deep saline reservoirs. Acid gas injection at smaller gas wells holds promise. However, in order for such injection programs to work, the progress of the injection plume must be tracked. A modeling study of fluid substitution was carried out to gain insight into the ability of seismic monitoring to distinguish pre- and post-injection states of the reservoir medium. The purpose of this study was to carry out fluid substitution calculations for the modeling of an injection process. A methodology that may be applied or adapted to a variety of acid-gas injection scenarios was also developed. The general approach involved determining acoustic properties at reservoir temperature and pressure of relevant fluids; obtaining elastic properties of the reservoir rock for some reference saturated state, and the elastic properties of the mineral comprising it; and, determining the change in reservoir elastic properties due to fluid substitution via Gassmann's equation. Water, brine and non-aqueous acid gas were the 3 fluids of interest in this case. The feasibility of monitoring was judged by the sensitivity of travel times and reflection coefficients to fluid substitution. 4 refs., 2 figs.
Gamma-irradiated scrub typhus immunogens: analysis for residual replicating rickettsiae
International Nuclear Information System (INIS)
Eisenberg, G.H. Jr.; Osterman, J.V.; Stephenson, E.H.
1980-01-01
Scrub thyphus immunogens that received inadequate gamma radiation contained residual, viable rickettsiae. The presence of these organisms in the host was masked by the rapid immune response elicited by the large number of inactivated rickettsiae. Transfer of homogenized spleen cells from immunized mice to normal syngeneic recipients provided a sensitive technique for the detection of these viable, replicating organisms
International Nuclear Information System (INIS)
Budzianowski, Wojciech M.; Wylock, Christophe E.; Marciniak, Przemysław A.
2017-01-01
Highlights: • Insights into power requirements of biomethane production from biogas are provided. • Process model is constructed, validated and simulated. • High-pressure and low-pressure plant operation in different configurations is compared. - Abstract: Biogas upgrading by water scrubbing followed by biomethane compression is an environmentally benign process. It may be achieved using various plant configurations characterised by various power requirements with associated effects on biomethane sustainability. Therefore, the current study has been undertaken to systematically investigate the power requirements of a range of water scrubbing options. Two groups of water scrubbing are analysed: (1) high pressure water scrubbing (HPWS) and (2) near-atmospheric pressure water scrubbing (NAPWS). A water scrubbing plant model is constructed, experimentally validated and simulated for seven upgrading plant configurations. Simulation results show that the power requirement of biogas upgrading in HPWS plants is mainly associated with biogas compression. In contrast, in NAPWS plants the main power is required for water pumping. In both plants the compression of the biomethane from atmosphereic pressure to 20 MPa also contributes remarkably. It is observed that the lowest specific power requirement can be obtained for a NAPWS plant without water regeneration (0.24 kW h/Nm"3 raw biogas) but this plant requires cheap water supply, e.g. outlet water from a sewage treatment plant or river. The second is HPWS without flash (0.29 kW h/Nm"3 raw biogas). All other HPWS with flash and NAPWS with water regeneration plants have specific power requirements between 0.30 and 0.33 kW h/Nm"3 raw biogas. Biogas compression without upgrading requires about 0.29 kW h/Nm"3 raw biogas. The thermodynamic efficiency of biogas upgrading is between 2.2% and 9.8% depending on the plant configuration while biomethane compression efficiency is higher, about 55%. This result implies that the
CO2 Capture from Flue Gas using Amino Acid Salt Solutions
DEFF Research Database (Denmark)
Lerche, Benedicte Mai; Stenby, Erling Halfdan; Thomsen, Kaj
2009-01-01
difficult. Amino acid salt solutions have emerged as an alternative to the alkanolamine solutions. A number of advantages make amino acid salt solutions attractive solvents for CO2 capture from flue gas. In the present study CO2 absorption in aqueous solutions of 0.5 M potassium glycinate and 0.5 M...
Hamaguchi, Sugihiro; Cuong, Ngo Chi; Tra, Doan Thu; Doan, Yen Hai; Shimizu, Kenta; Tuan, Nguyen Quang; Yoshida, Lay-Myint; Mai, Le Quynh; Duc-Anh, Dang; Ando, Shuji; Arikawa, Jiro; Parry, Christopher M.; Ariyoshi, Koya; Thuy, Pham Thanh
2015-01-01
A descriptive study on rickettsiosis was conducted at the largest referral hospital in Hanoi, Vietnam, to identify epidemiological and clinical characteristics of specific rickettsiosis. Between March 2001 and February 2003, we enrolled 579 patients with acute undifferentiated fever (AUF), excluding patients with malaria, dengue fever, and typhoid fever, and serologically tested for Orientia tsutsugamushi and Rickettsia typhi. Of the patients, 237 (40.9%) and 193 (33.3%) had scrub and murine typhus, respectively, and 149 (25.7%) had neither of them (non–scrub and murine typhus [non-ST/MT]). The proportion of murine typhus was highest among patients living in Hanoi whereas that of scrub typhus was highest in national or regional border areas. The presence of an eschar, dyspnea, hypotension, and lymphadenopathy was significantly associated with a diagnosis of scrub typhus (OR = 46.56, 10.90, 9.01, and 7.92, respectively). Patients with murine typhus were less likely to have these findings but more likely to have myalgia, rash, and relative bradycardia (OR = 1.60, 1.56, and 1.45, respectively). Scrub typhus and murine typhus were shown to be common causes of AUF in northern Vietnam although the occurrence of spotted fever group rickettsiae was not determined. Clinical and epidemiological information may help local clinicians make clinical diagnosis of specific rickettsioses in a resource-limited setting. PMID:25778504
Directory of Open Access Journals (Sweden)
M D Jamil
2015-01-01
Full Text Available Central nervous system (CNS involvement is a known complication of scrub typhus which range from mild meningitis to frank meninigoencephalitis.Aims and objectives: To study the clinical feature, laboratory parameters and response to treatment of scrub typhus meningitis/meningoencephalitis.Methods and Materials: This is a hospital based prospective observational study from North Eastern India. Diagnosis was based on clinical features and positive serological test (Weil's Felix test and IgM antibody card test.Results: 13 patients of scrub typhus with features of meningitis/meningoencephalitis were included. The mean duration of fever before presentation was 5.61±3.08 days and 4 (30.76 % patients had eschar. Altered sensorium, headache, seizure and meningeal sign were present in 13 (100%, 13 (100%, 6 (46.15% and 10 (76.92% patients respectively. Mean CSF protein, glucose and Adenosine deaminase was 152.16±16.88mg/dl, 55.23±21.7mg/dl, and 16.98±7.37U/L respectively. Mean total count of CSF leukocyte and lymphocyte percentage was 46.07±131 cell/cumm and 98.66±3.09% respectively. Tablet doxycycline with or without injection azithromycin was used and that shows good response 15.38% of patients died and all of them had multi organ dysfunction. Conclusion: Meningoencephalitis is a common manifestation of scrub typhus and diagnosis requires high degree of clinical suspicion which if diagnosed early and specific treatment started, patients usually recover completely with few complications.
Directory of Open Access Journals (Sweden)
Kiran Pote
2018-01-01
Full Text Available Background: Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. Methodology: The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. Results: We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15 than IgM IFA (sensitivity 96.8% and specificity 99.7% for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38% which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. Conclusion: IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.
Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep
2018-01-01
Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.
Stimulation of deep gas wells using HCl/formic acid system : lab studies and field application
Energy Technology Data Exchange (ETDEWEB)
Nasr-El-Din, H.A.; Al-Mutairi, S.; Al-Malki, B. [Saudi Aramco (Saudi Arabia); Metcalf, S.; Walters, W. [BJ Services Co USA, Houston, TX (United States)
2002-06-01
Well stimulation in the deep carbonate Khuff reservoirs in eastern Saudi Arabia is needed to remove drilling mud filter cakes and to enhance reservoir permeability. A non associated gas is being produced from the reservoirs. This gas is associated with the hydrogen sulfide content that varies from 0 to 10-mol per cent. The average reservoir temperature is 275 degrees F and initial reservoir pressure is 7,000 psi. A special system is needed to stimulate the carbonate reservoir because of this high bottomhole temperature and the corrosive nature of hydrochloric acid (HCl) at high temperature. A rotating disk method was used to determine the reaction rate of an HCl/formic acid system with reservoir rocks. Results from coreflood tests showed that the acid system creates deep wormholes in tight reservoir cores. Corrosion tests showed that the well tubulars could tolerate the acid system. A gelled 15-wt per cent HCl/9-wt per cent formic acid system successfully fractured 3 vertical wells in deep sour gas reservoirs without any operational problems. The treatment resulted in significant increases in gas production and flowing wellhead pressures. In addition, overflush of the treatment successfully eliminated the return of live acid after the treatment. 37 refs., 10 tabs., 17 figs.
David I. King; Richard B. Chandler; Jeffrey M. Collins; Wayne R. Petersen; Thomas E. Lautzenheiser
2009-01-01
Concern about declines in scrubâshrub bird populations has resulted in efforts to create and maintain habitat for these species. Vegetation within powerline corridors is managed to prevent contact of vegetation with transmission lines, and comprises approximately 2% of all of habitat for scrubâshrub birds in southern New England. Although previous studies have...
Horak, I G; Spickett, A M; Braack, L E; Penzhorn, B L
1993-09-01
A total of 264 scrub hares (Lepus saxatilis) were examined for ixodid ticks at various localities in the Kruger National Park, eastern Transvaal Lowveld. Thirteen tick species were recovered from these hares. The seasonal abundances of the immature stages of Amblyomma hebraeum, Amblyomma marmoreum, Hyalomma truncatum, Rhipicephalus appendiculatus, Rhipicephalus evertsi evertsi, Rhipicephalus simus and Rhipicephalus zambeziensis and all stages of a Rhipicephalus sp. (near R. pravus) were determined. Three scrub hares, examined in the north-western Transvaal Bushveld, were infested with five ixodid tick species. Ten hares examined in the eastern Transvaal Highveld harboured three species. A total of 15 ixodid tick species were recovered from the scrub hares examined in the three regions of the Transvaal. No haematozoa were found in blood smears made from the hares examined in the southern region of the Kruger National Park.
Gas chromatography of alkylphosphonic and dialkyl phosphinic acids
International Nuclear Information System (INIS)
Gasco Sanchez, L.; Barrera Pinero, R.; Ramirez Caceres, A.; Martin Munoz, M.
1978-01-01
After carrying out an optimization study on the separation conditions for the TMSr- derivatives, of the hexyl-, cyclohexyl-, heptyl-, and octyl-phosphonic acids; dihexyl dicyclohexyl-, heptyl-, and octyl-phosphinic acids, and dioctyl phosphine oxide, their retention indices (I) at two temperatures and on the OV-1 and OV-17 stationary phase were determined. Correlations between I and molecular structure were established. Calibration factors of these compounds in the flame ionization detector were studied, and the results analyzed taking into account the variables affecting the quantitative results, These results were unbiased but they had a lower precision than that usually achievable in gas chromatography. (Author) 24 refs
Amino acid salt solutions as solvents in CO2 capture from flue gas
DEFF Research Database (Denmark)
Lerche, Benedicte Mai; Thomsen, Kaj; Stenby, Erling Halfdan
New solvents based on the salts of amino acids have emerged as an alternative to the alkanolamine solutions, for the chemical absorption of CO2 from flue gas. But only few studies on amino acids as CO2 capturing agents have been performed so far. One of the interesting features of amino acid salt...... solutions is their ability to form solid precipitates upon the absorption of CO2. The occurrence of crystallization offers the possibility of increasing the CO2 loading capacity of the solvent. However, precipitation can also have negative effect on the CO2 capture process. The chemical nature of the solid...... of glycine, taurine, and lysine, while in the case of proline, and glutamic acid, the precipitate was found to be bicarbonate. These results give an important contribution to further understanding the potential of amino acid salt solutions in CO2 capture from flue gas....
Energy Technology Data Exchange (ETDEWEB)
Kail, Brian W; Link, Dirk D; Morreale, Bryan D
2012-11-01
A method for selectively determining both free fatty acids (FFA) and triacylglycerides (TAGs) in biological oils was investigated and optimized using gas chromatography after esterification of the target species to their corresponding fatty acid methyl esters (FAMEs). The method used acid catalyzed esterification in methanolic solutions under conditions of varying severity to achieve complete conversion of more reactive FFAs while preserving the concentration of TAGs. Complete conversion of both free acids and glycerides to corresponding FAMEs was found to require more rigorous reaction conditions involving heating to 120°C for up to 2 h. Method validation was provided using gas chromatography–flame ionization detection, gas chromatography–mass spectrometry, and liquid chromatography–mass spectrometry. The method improves on existing methods because it allows the total esterified lipid to be broken down by FAMEs contributed by FFA compared to FAMEs from both FFA and TAGs. Single and mixed-component solutions of pure fatty acids and triglycerides, as well as a sesame oil sample to simulate a complex biological oil, were used to optimize the methodologies. Key parameters that were investigated included: HCl-to-oil ratio, temperature and reaction time. Pure free fatty acids were found to esterify under reasonably mild conditions (10 min at 50°C with a 2.1:1 HCl to fatty acid ratio) with 97.6 ± 2.3% recovery as FAMEs, while triglycerides were largely unaffected under these reaction conditions. The optimized protocol demonstrated that it is possible to use esterification reactions to selectively determine the free acid content, total lipid content, and hence, glyceride content in biological oils. This protocol also allows gas chromatography analysis of FAMEs as a more ideal analyte than glyceride species in their native state.
Degradation of gas-liquid gliding arc discharge on Acid Orange II
International Nuclear Information System (INIS)
Yan, J.H.; Liu, Y.N.; Bo, Zh.; Li, X.D.; Cen, K.F.
2008-01-01
The effects of pH value, initial concentration of dye solution and temperature on the degradation efficiency of Acid Orange II (AO7) using gas-liquid gliding arc discharge were investigated. The influences of pH value and temperature on degradation efficiency were not apparent. Increasing initial solution concentration caused the decrease of degradation rate and the increase of absolute degradation quantity. Considering energy efficiency and absolute degradation quantity, the gas-liquid gliding arc discharge is fit for treating high concentration organic wastewater. A possible mineralization pathway was proposed through the analysis of intermediate products detected by gas chromatograph coupled with mass spectrophotometer (GC-MS) and ion chromatograph (IC). Hydroxyl radicals reacted with the azo linkage-bearing carbon of a hydroxy-substituted ring, leading to the cleavage of -C-N- and degradation of AO7. The solution biodegradability was significantly improved (BOD 5 /COD from 0.02 to 0.43). The toxicity of intermediate products was lower than that of the initial Acid Orange II
An outbreak investigation of scrub typhus in Western Province, Solomon Islands, 2014
Directory of Open Access Journals (Sweden)
Michael Marks
2016-01-01
Full Text Available Objective: To identify the etiology and risk factors of undifferentiated fever in a cluster of patients in Western Province, Solomon Islands, May 2014. Methods: An outbreak investigation with a case control study was conducted. A case was defined as an inpatient in one hospital in Western Province, Solomon Islands with high fever (> 38.5 °C and a negative malaria microscopy test admitted between 1 and 31 May 2014. Asymptomatic controls matched with the cases residentially were recruited in a ratio of 1:2. Serum samples from the subjects were tested for rickettsial infections using indirect micro-immunofluorescence assay. Results: Nine cases met the outbreak case definition. All cases were male. An eschar was noted in five cases (55%, and one developed pneumonitis. We did not identify any environmental factors associated with illness. Serum samples of all five follow-up cases (100% had strong-positive IgG responses to scrub typhus. All but one control (10% had a moderate response against scrub typhus. Four controls had low levels of antibodies against spotted fever group rickettsia, and only one had a low-level response to typhus group rickettsia. Discussion: This outbreak represents the first laboratory-confirmed outbreak of scrub typhus in the Western Province of Solomon Islands. The results suggest that rickettsial infections are more common than currently recognized as a cause of an acute febrile illness. A revised clinical case definition for rickettsial infections and treatment guidelines were developed and shared with provincial health staff for better surveillance and response to future outbreaks of a similar kind.
Rawat, Vinita; Singh, Rajesh Kumar; Kumar, Ashok; Saxena, Sandip R; Varshney, Umesh; Kumar, Mukesh
2018-04-01
We analysed the epidemiology, clinical and laboratory data of the 168 scrub typhus cases confirmed by a combination of any one of the following: real time polymerase chain reaction (RT-PCR) and/or immunofluorescence assay (IFA) (IgM and/or IgG). The peak season for scrub typhus was from July to October. By multivariate binary logistic regression analysis, the risk of scrub typhus was about four times in those working in occupation related to forest work. Major clinical manifestations were fever (100%), myalgia (65%), cough (51%) and vomiting (46%); major complications were meningitis/meningoencephatilitis (12.5%) and multi-organ failure (MOF) and pneumonia (5.3% each). Laboratory investigations revealed raised aminotranferase levels and thrombocytopenia in most confirmed cases. We conclude that scrub typhus is an important cause of febrile illness in the Kumaon hills of Uttarakhand where this disease had not previously been considered to exist.
Determination of Fatty Acid in Asparagus by Gas Chromatography
Directory of Open Access Journals (Sweden)
Zehra HAJRULAI-MUSLIU
2016-05-01
Full Text Available Asparagus contain a lot of macronutrients and micronutrients including folate, dietary fibre (soluble and insoluble and phenolic compounds. Also asparagus is a good source of unsaturated linoleic and linolenic fatty acids which are precursors for Eicosapentanoic acid (EPA and Docosahexanoic acid (DHA. Unsaturated fatty acids have important biological effects and they have important role in human health. The objective of this study was to analyze fatty acid composition of asparagus as a potential source of linoleic and linolenic acid - a precursor for EPA and DHA. For this reason we analyzed fifty seven samples of asparagus collected from the local market. We used AOAC 996.06 method and analyses were performed with gas chromatograph with flame-ionization detector (GC-FID. The highest concentration of fatty acid in the asparagus was linoleic acid (C18:2n6 which content in asparagus is 25.620±1.0%. Also, asparagus is good source of -linolenic fatty acid (C18:3n3 and content of this fatty acid in asparagus is 8.840±0.3%. The omega-6 to omega-3 (n6/n3 ratio in asparagus was 3.19. Polyunsaturated fatty acids (PUFAs were higher than monounsaturated fatty acids (MUFAs, and from saturated fatty acids, palmitic acid was most frequent with 24.324±1.0%. From our study we can conclude that asparagus is very good source of unsaturated fatty acids, especially linoleic and linolenic fatty acids.
Directory of Open Access Journals (Sweden)
D. A. Lack
2012-05-01
Full Text Available The International Maritime Organization (IMO has moved to address the health and climate impact of the emissions from the combustion of low-quality residual fuels within the commercial shipping industry. Fuel sulfur content (FS limits and an efficiency design index for future ships are examples of such IMO actions. The impacts of black carbon (BC emissions from shipping are now under review by the IMO, with a particular focus on the potential impacts of future Arctic shipping.
Recognizing that associating impacts with BC emissions requires both ambient and onboard observations, we provide recommendations for the measurement of BC. We also evaluate current insights regarding the effect of ship speed (engine load, fuel quality and exhaust gas scrubbing on BC emissions from ships. Observations demonstrate that BC emission factors (EFBC increases 3 to 6 times at very low engine loads (<25% compared to EFBC at 85–100% load; absolute BC emissions (per nautical mile of travel also increase up to 100% depending on engine load, even with reduced load fuel savings. If fleets were required to operate at lower maximum engine loads, presumably associated with reduced speeds, then engines could be re-tuned, which would reduce BC emissions.
Ships operating in the Arctic are likely running at highly variable engine loads (25–100% depending on ice conditions and ice breaking requirements. The ships operating at low load may be emitting up to 50% more BC than they would at their rated load. Such variable load conditions make it difficult to assess the likely emissions rate of BC.
Current fuel sulfur regulations have the effect of reducing EFBC by an average of 30% and potentially up to 80% regardless of engine load; a removal rate similar to that of scrubbers.
Uncertainties among current observations demonstrate there is a need for more information on a the impact of fuel quality
Energy Technology Data Exchange (ETDEWEB)
Mueller, H; Strauss, R; Hofmann, K -D; Suder, M; Hultsch, T; Wetzel, W; Gabrysch, H; Jung, J [Technische Hochschule, Zittau (German Democratic Republic)
1988-12-01
Reviews the technology applied in the Zittau process for flue gas heat recovery and flue gas desulfurization in small brown coal fired power plants. Steam generators have a capacity of 6.5 or 10 t/h, low grade fuel with 8.2 MJ/kg calorific value is combusted. Technology has been developed on an experimental 10 t/h steam generator since 1986; an industrial 6.5 t/h prototype steam generator is now in operation achieving 95% SO{sub 2} removal from flue gas with 5600 to 7800 mg SO{sub 2} per m{sup 3} of dry flue gas. The Zittau technology is available in 3 variants: with maximum waste heat recovery, with partial waste heat recovery or without waste heat recovery and only wet flue gas scrubbing. Two flowsheets of flue gas and suspension circulation are provided. The first variant recovers 25.7% of nominal heat capacity (1.1 thermal MW from a 4.2 MW steam generator with 6.5 t/h steam capacity), the second variant recovers 6.5% of waste heat by reducing heat exchangers to 20% of the size of the first variant. Flue gas suspension scrubbing utilizes power plant ash, which is capable of absorbing 50 to 70% of SO{sub 2}, additional 25% SO{sub 2} removal is achieved by providing either 40% ash from another power plant or limestone for suspensions. Various technological details are included. 5 refs.
Outbreak of scrub typhus in the North East Himalayan region-Sikkim: An emerging threat
Directory of Open Access Journals (Sweden)
S Gurung
2013-01-01
Full Text Available Scrub typhus is an acute febrile illness that is known to be endemic in the South East Asian countries and the Western Pacific region. We here report an outbreak in the tiny Himalayan state of Sikkim. Patients with pyrexia of unknown origin were evaluated. They were screened by Weil-Felix test and the rapid immunochromatographic method. Samples that were positive by either Weil-Felix agglutination test or by rapid immunochromatography were confirmed by IgM enzyme-linked immunosorbent assay (ELISA. A total 204 samples were screened. Sixty-three patients were confirmed positive among which 42 were male and 21 were female. Effective management and early administration of antibiotics will help prevent the complications and mortality associated with scrub typhus.
Amine-oxide hybrid materials for acid gas separations
Bollini, Praveen
2011-01-01
Organic-inorganic hybrid materials based on porous silica materials functionalized with amine-containing organic species are emerging as an important class of materials for the adsorptive separation of acid gases from dilute gas streams. In particular, these materials are being extensively studied for the adsorption of CO 2 from simulated flue gas streams, with an eye towards utilizing these materials as part of a post-combustion carbon capture process at large flue gas producing installations, such as coal-fired electricity-generating power plants. In this Application Article, the utilization of amine-modified organic-inorganic hybrid materials is discussed, focusing on important attributes of the materials, such as (i) CO 2 adsorption capacities, (ii) adsorption and desorption kinetics, and (iii) material stability, that will determine if these materials may one day be useful adsorbents in practical CO 2 capture applications. Specific research needs and limitations associated with the current body of work are identified. © 2011 The Royal Society of Chemistry.
International Nuclear Information System (INIS)
Broothaerts, J.; Claes, J.; Collard, G.; Goossens, W.; Harnie, R.; Heylen, P.; Vaesen, J.; Beukelaer, R. de; Dubois, G.; Glibert, R.; Mestrez, J.; Zahlen, A.
1975-06-01
Conceptual and experimental studies on LMFBR reprocessing and reactor off-gas purification systems are summarized. Iodine sorption on zeolites, low-temperature adsorption of noble gases on charcoal and catalytic oxidation of hydrogen, simulating tritium, are being studied in laboratory set-ups. A pilot loop with 25 m 3 h -1 throughput has been constructed. Results are quoted from the first phase of the iodine removal programme by scrubbing systems. Further extension of the test loop, comprising off-gases conditioning to removal of krypton in a cryodistillation unit, has been prepared. Delay-bed studies on 133 Xe extraction from LWR off-gases are reported. (author)
Kraussler, Michael; Schindler, Philipp; Hofbauer, Hermann
2017-08-01
This work presents an experimental approach aiming the production of a gas mixture composed of H 2 and CH 4 , which should serve as natural gas substitute in industrial applications. Therefore, a lab-scale process chain employing a water gas shift unit, scrubbing units, and a pressure swing adsorption unit was operated with tar-rich product gas extracted from a commercial dual fluidized bed biomass steam gasification plant. A gas mixture with a volumetric fraction of about 80% H 2 and 19% CH 4 and with minor fractions of CO and CO 2 was produced by employing carbon molecular sieve as adsorbent. Moreover, the produced gas mixture had a lower heating value of about 15.5MJ·m -3 and a lower Wobbe index of about 43.4MJ·m -3 , which is similar to the typical Wobbe index of natural gas. Copyright © 2017 Elsevier Ltd. All rights reserved.
Varghese, George M; Janardhanan, Jeshina; Trowbridge, Paul; Peter, John V; Prakash, John A J; Sathyendra, Sowmya; Thomas, Kurien; David, Thambu S; Kavitha, M L; Abraham, Ooriapadickal C; Mathai, Dilip
2013-11-01
This study sought to document the clinical and laboratory manifestations, genetic variability, and outcomes of scrub typhus, an often severe infection caused by Orientia tsutsugamushi, in South India. Patients admitted to a large teaching hospital with IgM ELISA-confirmed scrub typhus were evaluated. Clinical examination with a thorough search for an eschar, laboratory testing, chest X-ray, and outcome were documented and analyzed. Additionally, a 410-bp region of the 56-kDa type-specific antigen gene of O. tsutsugamushi was sequenced and compared with isolates from other regions of Asia. Most of the 154 patients evaluated presented with fever and non-specific symptoms. An eschar was found in 86 (55%) patients. Mild hepatic involvement was seen in most, with other organ involvement including respiratory, cardiovascular, and renal. Multi-organ dysfunction was noted in 59 (38.3%), and the fatality rate was 7.8%. Hypotension requiring vasoactive agents was found to be an independent predictor of mortality (p<0.001). The phylogeny of 26 samples showed 17 (65%) clustering with the Kato-like group and eight (31%) with the Karp-like group. The presentation of scrub typhus can be variable, often non-specific, but with potentially severe multi-organ dysfunction. Prompt recognition is key to specific treatment and good outcomes. Further study of the circulating strains is essential for the development of a successful vaccine and sensitive point-of-care testing. Copyright © 2013 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
International Nuclear Information System (INIS)
Cau Dit Coumes, C.; Devisme, F.; Chopin, J.; Vargas, S.
1996-01-01
Iodine, which can be released inside the containment buildings when accident occurs, can be traced, in normal operating conditions, at the back end of the fuel cycle. Hydroxylamine has been selected as a regent of potential interest to trap iodine in the dissolution off gas treatment. The kinetics of the reaction between hydroxylamine and iodine has been studied in a narrow range of pH(1-2), with hydroxylamine in excess (ratios of hydroxylamine to iodine initial concentrations varying from 2 to 40), at constant temperature (30 deg. C) and ionic strength (0.1 mol/l). Spectrophotometry and voltametry have been coupled for analytical solved using a investigation. The problem of the rapid mixing of the reactants has been solved using a continuous reactor. Tri-iodine has been shown non reactive towards hydroxylamine. An initial rate law have been proposed, pointing out the first order of the reaction with respect to hydroxylamine and iodine, and the inhibitory effect and hydrogen ions. Nitrous acid has been identified as a transitory product. Nitrous oxide and nitrogen monoxide have been detected by gas chromatography, the ratio of the amounts of products formed depending on acidity. The complexity of the overall reaction has been ascribed to the competition of hour reactions (I 2 + I I 3 - NH 3 OH + + 2 I 2 + H 2 O ->HNO 2 + 4 I - + 5 H + ; NH 3 OH + + HNO 2 -> N 2 O + 2 H 2 O + H-+ 2HNO 2 + 2 I - + 2H-+ -> 2 NO + I 2 + H 2 O). (authors)
Recovering of uranium from phosphoric acid produced by the wet process
International Nuclear Information System (INIS)
Barreiro, A.J.; Lyon, W.L.; Holleman, R.A.; Randell, C.C.
1977-01-01
Process for recovering uranium as from an aqueous solution of phosphoric acid arising from a wet process, with a scrubbing agent essentially composed of a hydrocarbon whose boiling point is situated between 150 0 C and 300 0 C, which reacts with the contaminents formed in the sludge in the phosphoric acid, in an efficient enough quantity to wash the contamination products forming the phosphoric acid sludge, give a sludge phase and a purified phosphoric acid phase, after which the sludge phase is extracted [fr
Measurements of atmospheric nitrous acid and nitric acid
Huang, Gu; Zhou, Xianliang; Deng, Guohong; Qiao, Huancheng; Civerolo, Kevin
A highly sensitive technique for the measurement of atmospheric HONO and HNO 3 is reported. The technique is based on aqueous scrubbing using two coil samplers, followed by conversion of HNO 3 to nitrite, derivatization of nitrite to a highly light-absorbing azo dye with sulfanilamide (SA) and N-(1-naphthyl) ethylenediamine (NED), and high performance liquid chromatography (HPLC) analysis. HNO 3 concentration was obtained by the difference of the two channels. Two scrubbing solutions were used for sampling the two species: a 1-mM phosphate buffer solution (pH 7) for the measurement of HONO and a 180 mM NH 4Cl/NH 3 buffer solution (pH 8.5) for the measurement of HONO+HNO 3. The scrubbing solution flow rate was 0.24 ml min -1 and the gas sampling flow rate was 2 l min -1. HNO 3 in the NH 4Cl/NH 3 buffer solution was quantitatively reduced to nitrite along an on-line 0.8-cm Cd reductor column. Nitrite in both channels was derivatized with 2 mM SA and 0.2 mM NED in 25 mM HCl. Quantitative derivatization was achieved within 5 min at 55°C. The azo dye derivative was then separated from the SA/NED reagent by reversed-phase HPLC and detected with a UV-vis detector at 540 nm. With an on-line SEP-PAK C-18 cartridge for the reagent purification, the method detection limit is estimated to be better than 1 pptv for HONO and about 20 pptv for HNO 3. The sample integration time was about 2 min and the sampling frequency is every 10 min. Data collected in downtown Albany and Whiteface Mountain, NY, are shown as examples of applications of this technique in both urban and remote clean environments.
Feedlot lamb meat fatty acids profile characterization employing gas chromatography
Directory of Open Access Journals (Sweden)
M.I. Cruz-Gonzalez
2014-06-01
Full Text Available Fat is an important constituent in diet, not only as an energy source, but for its essential fatty acids associated to fats in foods, considering that some polyunsaturated fatty acids like linoleic, linolenic and arachidonic cannot be synthesized by superior animals like humans. Scientific evidence show that the fatty acids ingest can affect the thrombotic tendency, cardiac rhythm, endothelial function systematic inflammation, insulin sensibility and oxidative stress. Samples from 21 ovine crossbreds from Pelibuey, Blackbelly, Dorper and Katahadin (40 kg average weight feed with corn based balanced diets were taken from loin area 18 h after refrigeration. Saturated and polyunsaturated fatty acids levels were analyzed by gas chromatography. Results in this work showed that the healthy fatty acids levels are higher as compared to saturated fatty acids levels, indicating that this meat can influence consumer’s buying choice decision regarded to their health.
Directory of Open Access Journals (Sweden)
Lynn Soong
2016-08-01
Full Text Available Scrub typhus is a neglected tropical disease, caused by Orientia tsutsugamushi, a Gram-negative bacterium that is transmitted to mammalian hosts during feeding by Leptotrombidium mites and replicates predominantly within endothelial cells. Most studies of scrub typhus in animal models have utilized either intraperitoneal or intravenous inoculation; however, there is limited information on infection by the natural route in murine model skin or its related early host responses. Here, we developed an intradermal (i.d. inoculation model of scrub typhus and focused on the kinetics of the host responses in the blood and major infected organs. Following ear inoculation with 6 x 104 O. tsutsugamushi, mice developed fever at 11-12 days post-infection (dpi, followed by marked hypothermia and body weight loss at 14-19 dpi. Bacteria in blood and tissues and histopathological changes were detected around 9 dpi and peaked around 14 dpi. Serum cytokine analyses revealed a mixed Th1/Th2 response, with marked elevations of MCP-1/CCL2, MIP-1α/CCL3 and IL-10 at 9 dpi, followed by increased concentrations of pro-inflammatory markers (IL-6, IL-12, IFN-γ, G-CSF, RANTES/CCL5, KC/CCL11, IL-1α/β, IL-2, TNF-α, GM-CSF, as well as modulatory cytokines (IL-9, IL-13. Cytokine levels in lungs had similar elevation patterns, except for a marked reduction of IL-9. The Orientia 47-kDa gene and infectious bacteria were detected in several organs for up to 84 dpi, indicating persistent infection. This is the first comprehensive report of acute scrub typhus and persistent infection in i.d.-inoculated C57BL/6 mice. This is a significant improvement over current murine models for Orientia infection and will permit detailed studies of host immune responses and infection control interventions.
Gas Phase Hydrogenation of Levulinic Acid to gamma-Valerolactone
Bonrath, Werner; Castelijns, Anna Maria Cornelia Francisca; de Vries, Johannes Gerardus; Guit, Rudolf Philippus Maria; Schuetz, Jan; Sereinig, Natascha; Vaessen, Henricus Wilhelmus Leonardus Marie
The gas phase hydrogenation of levulinic acid to gamma-valerolactone over copper and ruthenium based catalysts in a continuous fixed-bed reactor system was investigated. Among the catalysts a copper oxide based one [50-75 % CuO, 20-25 % SiO2, 1-5 % graphite, 0.1-1 % CuCO3/Cu(OH)(2)] gave
Ruminal Methane Production on Simple Phenolic Acids Addition in in Vitro Gas Production Method
Directory of Open Access Journals (Sweden)
A. Jayanegara
2009-04-01
Full Text Available Methane production from ruminants contributes to total global methane production, which is an important contributor to global warming. In this experiment, six sources of simple phenolic acids (benzoic, cinnamic, phenylacetic, caffeic, p-coumaric and ferulic acids at two different levels (2 and 5 mM added to hay diet were evaluated for their potential to reduce enteric methane production using in vitro Hohenheim gas production method. The measured variables were gas production, methane, organic matter digestibility (OMD, and short chain fatty acids (SCFA. The results showed that addition of cinnamic, caffeic, p-coumaric and ferulic acids at 5 mM significantly (P p-coumaric > ferulic > cinnamic. The addition of simple phenols did not significantly decrease OMD. Addition of simple phenols tends to decrease total SCFA production. It was concluded that methane decrease by addition of phenolic acids was relatively small, and the effect of phenolic acids on methane decrease depended on the source and concentration applied.
Energy Technology Data Exchange (ETDEWEB)
Singh, D; Croiset, E; Douglas, P L [Waterloo Univ., Dept. of Chemical Engineering, Waterloo, ON (Canada); Douglas, M A [Natural Resources Canada, CANMET Energy Technology Centre, Nepean, ON (Canada)
2003-11-01
The existing fleet of modern pulverised coal fired power plants represents an opportunity to achieve significant reductions in greenhouse gas emissions in the coming years providing that efficient and economical CO{sub 2} capture technologies are available for retrofit. One option is to separate CO{sub 2} from the products of combustion using conventional approaches such as amine scrubbing. An emerging alternative, commonly known as O{sub 2}/CO{sub 2} recycle combustion, involves burning the coal with oxygen in an atmosphere of recycled flue gas. Both approaches can be retrofitted to existing units, however they consume significant amounts of energy to capture, purify and compress the CO{sub 2} for subsequent sequestration. This paper presents a techno-economic comparison of the performance of the two approaches. The comparison was developed using the commercial process simulation packages, Hysys and Aspen Plus. The results show that both processes are expensive options to capture CO{sub 2} from coal power plants, however O{sub 2}/CO{sub 2} appears to be a more attractive retrofit than MEA scrubbing. The CO{sub 2} capture cost for the MEA case is USD 53/ton of CO{sub 2} avoided, which translates into 3.3 cent/kW h. For the O{sub 2}/CO{sub 2} case the CO{sub 2} capture cost is lower at USD 35/ton of CO{sub 2} avoided, which translates into 2.4 cent/kW h. These capture costs represent an approximate increase of 20-30% in current electricity prices. (Author)
Cheung, Pui Kwan; Fok, Lincoln
2017-10-01
Plastic microbeads are often added to personal care and cosmetic products (PCCPs) as an abrasive agent in exfoliants. These beads have been reported to contaminate the aquatic environment and are sufficiently small to be readily ingested by aquatic organisms. Plastic microbeads can be directly released into the aquatic environment with domestic sewage if no sewage treatment is provided, and they can also escape from wastewater treatment plants (WWTPs) because of incomplete removal. However, the emissions of microbeads from these two sources have never been estimated for China, and no regulation has been imposed on the use of plastic microbeads in PCCPs. Therefore, in this study, we aimed to estimate the annual microbead emissions in Mainland China from both direct emissions and WWTP emissions. Nine facial scrubs were purchased, and the microbeads in the scrubs were extracted and enumerated. The microbead density in those products ranged from 5219 to 50,391 particles/g, with an average of 20,860 particles/g. Direct emissions arising from the use of facial scrubs were estimated using this average density number, population data, facial scrub usage rate, sewage treatment rate, and a few conservative assumptions. WWTP emissions were calculated by multiplying the annual treated sewage volume and estimated microbead density in treated sewage. We estimated that, on average, 209.7 trillion microbeads (306.9 tonnes) are emitted into the aquatic environment in Mainland China every year. More than 80% of the emissions originate from incomplete removal in WWTPs, and the remaining 20% are derived from direct emissions. Although the weight of the emitted microbeads only accounts for approximately 0.03% of the plastic waste input into the ocean from China, the number of microbeads emitted far exceeds the previous estimate of plastic debris (>330 μm) on the world's sea surface. Immediate actions are required to prevent plastic microbeads from entering the aquatic environment
Varghese, George M; Janardhanan, Jeshina; Mahajan, Sanjay K; Tariang, David; Trowbridge, Paul; Prakash, John A J; David, Thambu; Sathendra, Sowmya; Abraham, O C
2015-01-01
Scrub typhus, an acute febrile illness that is widespread in the Asia-Pacific region, is caused by the bacterium Orientia tsutsugamushi, which displays high levels of antigenic variation. We conducted an investigation to identify the circulating genotypes of O. tsutsugamushi in 3 scrub typhus-endemic geographic regions of India: South India, Northern India, and Northeast India. Eschar samples collected during September 2010-August 2012 from patients with scrub typhus were subjected to 56-kDa type-specific PCR and sequencing to identify their genotypes. Kato-like strains predominated (61.5%), especially in the South and Northeast, followed by Karp-like strains (27.7%) and Gilliam and Ikeda strains (2.3% each). Neimeng-65 genotype strains were also observed in the Northeast. Clarifying the genotypic diversity of O. tsutsugamushi in India enhances knowledge of the regional diversity among circulating strains and provides potential resources for future region-specific diagnostic studies and vaccine development.
Energy Technology Data Exchange (ETDEWEB)
Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
2017-10-06
An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D(Cs) results.
Directory of Open Access Journals (Sweden)
R Pai
2016-01-01
Full Text Available Scrub typhus is emerging as an important cause of acute febrile illness in Northern India. This is a report of two sisters presenting concurrently with acute respiratory distress syndrome. A diagnosis of scrub typhus was made in both the patients, and they were successfully treated with doxycycline.
Janardhanan, Jeshina; Joseph Martin, Sherry; Astrup, Elisabeth; Veeramanikandan, R; Aukrust, Pål; Abraham, Ooriapadickal C; Varghese, George M
2013-11-01
Scrub typhus is a highly prevalent bacterial infection in India and South Asia that is caused by Orientia tsutsugamushi. The innate immune response to infections is modulated by Toll-like receptors (TLRs) and heat shock proteins (HSPs). This study was done to assess the prevalence and possible association of TLR and HSP polymorphisms in scrub typhus. TLR4 Asp299Gly, TLR4 Thr399Ile, TLR2 Arg753Gln and HSP70-2 A1267G are single-nucleotide polymorphisms (SNPs) that may modulate their activities, and these SNPs were assessed in 137 scrub typhus patients and 134 controls by PCR restriction fragment length polymorphism. We found that the two TLR4 mutations, TLR4 D299G and TLR4T399I, were present in 19.5% and 22% of the study population, respectively, and was in significant linkage disequilibrium with a D' of 0.8. The TLR2 mutation was found to be rare, whereas the HSP A>G mutation was very common (77.5%). Compared with the controls, the prevalence of heterozygous genotype of the TLR4D299G SNP, but not any of the other SNPs, was significantly higher among scrub typhus patients. Further studies using a larger sample size and more candidate genes may better enable in determining the role of these associations in susceptibility and severity of scrub typhus.
Gas-phase salt bridge interactions between glutamic acid and arginine
Jaeqx, S.; Oomens, J.; Rijs, A.M.
2013-01-01
The gas-phase side chain-side chain (SC-SC) interaction and possible proton transfer between glutamic acid (Glu) and arginine (Arg) residues are studied under low-temperature conditions in an overall neutral peptide. Conformation-specific IR spectra, obtained with the free electron laser FELIX, in
Rapid increase of scrub typhus incidence in Guangzhou, southern China, 2006-2014
Y. Sun (Ye); Wei, Y.-H. (Yue-Hong); Yang, Y. (Yang); Ma, Y. (Yu); S.J. de Vlas (Sake); H.-W. Yao (Hong-Wu); Huang, Y. (Yong); Ma, M.-J. (Mai-Juan); K. Liu (Kun); Li, X.-N. (Xiao-Ning); X. Li (Xinlou); Zhang, W.-H. (Wen-Hui); Fang, L.-Q. (Li-Qun); Yang, Z.-C. (Zhi-Cong); Cao, W.-C. (Wu-Chun)
2017-01-01
textabstractBackground: In the last decade, scrub typhus (ST) has been emerging or re-emerging in some areas of Asia, including Guangzhou, one of the most affected endemic areas of ST in China. Methods: Based on the data on all cases reported in Guangzhou from 2006 to 2014, we characterized the
Carbon dioxide removal with inorganic membranes
Energy Technology Data Exchange (ETDEWEB)
Judkins, R.R.; Fain, D.E. [Oak Ridge National Laboratory, TN (United States)
1993-12-31
The increasing concentrations of greenhouse gases, particularly carbon dioxide, in the atmosphere has sparked a great deal of interest in the removal of CO{sub 2} from flue gases of fossil fueled plants. Presently, several techniques for the removal of CO{sub 2} are considered to have potential, but are lacking in practicality. For example, amine scrubbing of flue gas streams is potential, but are lacking in practically. For example, amine scrubbing of flue gas streams is effective in removing CO{sub 2}, but costs are high; efficiency suffers; and other acid gases must be removed prior to amine stripping. Membrane systems for CO{sub 2} removal are held in high regard, and inorganic, particularly ceramic, membranes offer the potential for high temperature, thus energy saving, removal.
Energy Technology Data Exchange (ETDEWEB)
Cau Dit Coumes, C.; Devisme, F. [CEA Centre d`Etudes de la Vallee du Rhone, 30 - Marcoule (France). Dept. d`Exploitation du Retraitement et de Demantelement; Chopin, J.; Vargas, S.
1996-12-31
Iodine, which can be released inside the containment buildings when accident occurs, can be traced, in normal operating conditions, at the back end of the fuel cycle. Hydroxylamine has been selected as a regent of potential interest to trap iodine in the dissolution off gas treatment. The kinetics of the reaction between hydroxylamine and iodine has been studied in a narrow range of pH(1-2), with hydroxylamine in excess (ratios of hydroxylamine to iodine initial concentrations varying from 2 to 40), at constant temperature (30 deg. C) and ionic strength (0.1 mol/l). Spectrophotometry and voltametry have been coupled for analytical solved using a investigation. The problem of the rapid mixing of the reactants has been solved using a continuous reactor. Tri-iodine has been shown non reactive towards hydroxylamine. An initial rate law have been proposed, pointing out the first order of the reaction with respect to hydroxylamine and iodine, and the inhibitory effect and hydrogen ions. Nitrous acid has been identified as a transitory product. Nitrous oxide and nitrogen monoxide have been detected by gas chromatography, the ratio of the amounts of products formed depending on acidity. The complexity of the overall reaction has been ascribed to the competition of hour reactions (I{sub 2} + I <=> I{sub 3}{sup -}NH{sub 3}OH{sup +} + 2 I{sub 2} + H{sub 2}O ->HNO{sub 2} + 4 I{sup -} + 5 H{sup +}; NH{sub 3}OH{sup +} + HNO{sub 2} -> N{sub 2}O + 2 H{sub 2}O + H-+ 2HNO{sub 2} + 2 I{sup -} + 2H-+ -> 2 NO + I{sub 2} + H{sub 2}O). (authors). 12 refs.
DEFF Research Database (Denmark)
Engvild, Kjeld Christensen; Egsgaard, Helge; Larsen, Elfinn
1980-01-01
4-Chloroindole-3-acetic acid methyl ester was identified unequivocally in Lathyrus latifolius L., Vicia faba L. and Pisum sativum L. by thin layer chromatography, gas chromatography and mass spectrometry. The gas chromatographic system was able to separate underivatized chloroindole-3-acetic acid...... methyl ester isomers. The quantitative determination of 4-chloroindole-3-acetic acid methyl ester in immature seeds of these three species was performed by gas chromatography – mass spectrometry using deuterium labelled 4-chloro-indole-3-acetic acid methyl ester as an internal standard. P. sativum...
Hybrid ATDL-gamma distribution model for predicting area source acid gas concentrations
Energy Technology Data Exchange (ETDEWEB)
Jakeman, A J; Taylor, J A
1985-01-01
An air quality model is developed to predict the distribution of concentrations of acid gas in an urban airshed. The model is hybrid in character, combining reliable features of a deterministic ATDL-based model with statistical distributional approaches. The gamma distribution was identified from a range of distributional models as the best model. The paper shows that the assumptions of a previous hybrid model may be relaxed and presents a methodology for characterizing the uncertainty associated with model predictions. Results are demonstrated for the 98-percentile predictions of 24-h average data over annual periods at six monitoring sites. This percentile relates to the World Health Organization goal for acid gas concentrations.
Jang, Mi-Ok; Kim, Ji Eun; Kim, Uh Jin; Ahn, Joon Hwan; Kang, Seung-Ji; Jang, Hee-Chang; Jung, Sook-In; Park, Kyung-Hwa
2014-01-01
Age can affect the clinical features and severity of infectious disorders, such as scrub typhus. We performed this study to examine differences between elderly and non-elderly scrub typhus patients, and to identify risk factors predictive of disease outcomes. This retrospective study included patients admitted to a tertiary hospital with scrub typhus between 2001 and 2011. A total of 615 patients were enrolled in this study, 328 of which were >65 years of age. Of the elderly patients, 46.0% (151/328) experienced at least one complication compared to only 23.0% (66/287) in younger patients. A linear trend was observed between age and complication rates (p=0.002). The most common complication in elderly patients was acute kidney injury (75, 22.9%). Treatment failure was reported in 10 elderly patients (3.0%) compared to one non-elderly patient (0.3%). Mental confusion and dyspnea of clinical manifestations at admission were common in elderly patients. Frequency of fever, rash, and eschar were similar in both groups. The following four factors were significantly associated with severe scrub typhus in elderly patients: (1) white blood cell (WBC) counts>10,000/mm(3) (OR=2.569, CI=1.298-5.086), (2) MDRD GFR10 points (OR=3.304, CI=1.793-60.87). Complications and mortality were more common in elderly patients, often associated with delays in diagnosis and treatment. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
International Nuclear Information System (INIS)
Bahner, C.T.; Shoun, R.R.; McDowell, W.J.
1981-11-01
The effects of exposure to gamma radiation ( 60 Co) and of contact with acidic and basic aqueous solutions on dihexyl[(diethylcarbamoyl)methyl]phosphonate (DHDECMP) were studied. Gamma radiation decomposes DHDECMP into a variety of products. The most troublesome of those are the acidic compounds that cause problems in stripping the actinides and lanthanides from the extractant at low acid concentrations. The rate of degradation of DHDECMP by radiation is about the same or only slightly higher than that of tri-n-butyl phosphate (TBP). It is relatively easy to remove the radiation-produced impurities by equilibration (scrubbing) with sodium carbonate or sodium hydroxide or by column chromatographic methods. The hydrolysis of DHDECMP in contact with aqueous solutions containing less than 3 M HNO 3 is not more severe than that of TBP under the same conditions but is significant above that acid concentration. Hydrolysis of DHDECMP in contact with aqueous sodium hydroxide solution does occur, but it should not pose an important problem with the short contact times such as those anticipated for the removal of the radiation-induced degradation products by caustic scrubbing. Results of various chromatographic tests to characterize the degradation products of DHDECMP are also given
Directory of Open Access Journals (Sweden)
IZZATI NADIA MOHAMAD
2017-03-01
Full Text Available To date, a high energy demand has led to massive research efforts towards improved gas-separation techniques for more energy-efficient and environmenttally friendly methods. One of the potential alternative energies is biogas produced from the fermentation of liquid waste generated from the oil-extraction process, which is known as palm oil mill effluent (POME. Basically, the gas produced from the POME fermentation process consists mainly of a CO2 and H2 gas mixture. CO2 is known as an anthropogenic greenhouse gas, which contributes towards the climate change phenomenon. Hence, it is crucial to determine a suitable technique for H2 separation and purification with good capability for CO2 capture, as this will reduce CO2 emission to the environment as well. This paper reviewed the current gas-separation techniques that consist of absorption, adsorption and a membrane in order to determine the advantages and disadvantages of these techniques towards the efficiency of the separation system. Crucial aspects for gas-separation techniques such as energy, economic, and environmental considerations are discussed, and a potential biohydrogen and biogas-upgrading technique for industrial POME application is presented and concluded in this paper. Based on the comparison on these aspects, water scrubbing is found to be the best technique to be used in the biogas-upgrading industry, followed by membrane and chemical scrubbing as well as PSA. Hence, these guidelines are justified for selecting the best gas-upgrading technique to be used in palm oil mill industry applications.
Jang, Mi-Ok; Jang, Hee-Chang; Kim, Uh Jin; Ahn, Joon Hwan; Kang, Seung-Ji; Jung, Sook-In; Shin, Hee-Young
2014-01-01
There are no well-matched, controlled studies comparing azithromycin with doxycycline for the treatment of complicated scrub typhus. A retrospective propensity score-matched case-control study was performed for patients who presented with complicated scrub typhus and were treated with doxycycline or azithromycin between 2001 and 2011. Data on comorbidities, clinical manifestations, laboratory studies, treatments, and outcomes were extracted for analysis. The clinical characteristics and outcomes of the azithromycin-treated group (n = 73) were compared to those of the doxycycline-treated group (n = 108). Of 181 patients, 73 from each group were matched by propensity scores. There were no significant differences in baseline characteristics between the matched groups. The treatment success and survival rates were not significantly different (89% [65/73 patients] versus 96% [70/73 patients] and 96% [70/73 patients] versus 96% [70/73 patients], respectively [P > 0.05]). No difference was observed in the time to defervescence or length of hospital stay between the two groups (P > 0.05). In complicated scrub typhus patients (n = 181), multivariate analysis showed that only APACHE II score was an independent risk factor for mortality (95% confidence interval, 1.11 to 1.56; P scrub typhus. PMID:24366734
Removal of fine particles in wet flue gas desulfurization system by heterogeneous condensation
Energy Technology Data Exchange (ETDEWEB)
Yang, L.J.; Bao, J.J.; Yan, J.P.; Liu, J.H.; Song, S.J.; Fan, F.X. [Southeast University, Nanjing (China). School of Energy & Environment
2010-01-01
A novel process to remove fine particles with high efficiency by heterogeneous condensation in a wet flue gas desulfurization (WFGD) system is presented. A supersaturated vapor phase, necessary for condensational growth of fine particles, was achieved in the SO{sub 2} absorption zone and at the top of the wet FGD scrubber by adding steam in the gas inlet and above the scrubbing liquid inlet of the scrubber, respectively. The condensational grown droplets were then removed by the scrubbing liquid and a high-efficiency demister. The results show that the effectiveness of the WFGD system for removal of fine particles is related to the SO{sub 2} absorbent employed. When using CaCO{sub 3} and NH{sub 3} {center_dot} H{sub 2}O to remove SO{sub 2} from flue gas, the fine particle removal efficiencies are lower than those for Na2CO{sub 3} and water, and the morphology and elemental composition of fine particles are changed. This effect can be attributed to the formation of aerosol particles in the limestone and ammonia-based FGD processes. The performance of the WFGD system for removal of fine particles can be significantly improved for both steam addition cases, for which the removal efficiency increases with increasing amount of added steam. A high liquid to gas ratio is beneficial for efficient removal of fine particles by heterogeneous condensation of water vapor.
Giri, Prabahs Prasun; Roy, Joydeb; Saha, Agnisekhar
2018-02-01
Scrub typhus has been globally recognized as an emerging infectious disease contributing significantly to pyrexia of unknown origin (PUO) and a potential cause of multiorgan dysfunction syndrome (MODS). We studied the incidence of scrub typhus as a cause of pediatric intensive care unit (PICU) admission and MODS in our hospital and its clinical and laboratory characteristics to measure the incidence of MODS caused by scrub typhus. This study was done in a pediatric teaching hospital in Kolkata, India. Records of patients admitted with PUO from March 2012 to December 2015 were reviewed. Rathi-Goodman-Aghai scoring system was used to identify potential ST patients and confirmed by serological testing. Clinical characteristics, laboratory findings, and treatment response were noted of those needing PICU admissions. Ninety-seven cases of scrub typhus have been identified during that period. PICU admission was needed in 30 of them (31%) which contributed 8.43% of total PICU admissions. Among these 30 patients, 16 (53%) developed MODS which contributed 18.29% of total MODS admitted in PICU. Septic shock was the most common manifestation in as many as 18 (60%) patients followed by encephalopathy in 13 (43%). Patients were treated with either doxycycline alone or in combination with azithromycin. Mean time to complete defervescence was 32 h after first dose of doxycycline. The outcome was excellent without a single mortality. Scrub typhus is an important cause of MODS in this part of the world, especially in fevers associated with features as identified and not responding to conventional antibiotics.
A rapid, sensitive and reliable diagnostic test for scrub typhus in China
Directory of Open Access Journals (Sweden)
Zhang Lijuan
2011-01-01
Full Text Available Purpose: To evaluate the performances for detection of IgM and IgG antibodies to Orientia. tsutsugamushi (Ot using a gold conjugate-based rapid diagnostic test (RDT. Materials and Methods: The RDT employing mixture recombinant 56-kDa proteins of O. tsutsugamushi and the mIFA assay was performed on 33 patients from Fujian and Yunnan province respectively and 94 positive sera (36 from Hainan province and 58 from Jiangsu province from convalescent stages of the patients with scrub typhus respectively and 82 negative sera from healthy farmers from Anhui province and Beijing City respectively in 2009. A comparison of the RDT and mIFA assay was performed by using the c2 test and the P level of ≤0.05 was considered to be significant. Results: Among these 94 positive sera from convalescent stages of the illness and 82 sera from control farmers, the specificity of RDT was 100% for both IgM and IgG tests. In 33 cases with scrub typhus, 5 cases were positively detected earlier by RDT than by mIFA for the IgM test, and 2 cases were positive for the IgG test. The sensitivities of RDT were 93.9% and 90.9% for IgM and IgG, respectively. Considering IgM and IgG together, the sensitivity was 100%. The geometric mean titre (GMT of IFA and the RDT assay in diluted sera from confirmed cases were 1:37 versus 1:113 respectively (P<0.001 for IgM test and 1:99 versus 1:279 respectively (P<0.016 for IgG. Conclusions: The RDT was more sensitive than the traditional IFA for the early diagnosis of scrub typhus and was particularly suitable for use in rural areas.
Acid gas control process and apparatus for waste fired incinerators
International Nuclear Information System (INIS)
Kubin, P.Z.; Stepan, J.E.
1992-01-01
This patent describes a process for reducing noxious emission produced in a waste material incinerator. It comprises incinerating solid waste material in a furnace section of the waste material incinerator; providing an additive to an additive supply storage unit; conveying the additive to an additive injection means that communicates with the furnace section of the waste material incinerator; injecting the additive into a turbulent reaction zone of the furnace section such that acid gas content, acid dewpoint temperature and the level of corrosion in the incinerator are reduced
Estimation of combustion flue gas acid dew point during heat recovery and efficiency gain
Energy Technology Data Exchange (ETDEWEB)
Bahadori, A. [Curtin University of Technology, Perth, WA (Australia)
2011-06-15
When cooling combustion flue gas for heat recovery and efficiency gain, the temperature must not be allowed to drop below the sulfur trioxide dew point. Below the SO{sub 3} dew point, very corrosive sulfuric acid forms and leads to operational hazards on metal surfaces. In the present work, simple-to-use predictive tool, which is easier than existing approaches, less complicated with fewer computations is formulated to arrive at an appropriate estimation of acid dew point during combustion flue gas cooling which depends on fuel type, sulfur content in fuel, and excess air levels. The resulting information can then be applied to estimate the acid dew point, for sulfur in various fuels up to 0.10 volume fraction in gas (0.10 mass fraction in liquid), excess air fractions up to 0.25, and elemental concentrations of carbon up to 3. The proposed predictive tool shows a very good agreement with the reported data wherein the average absolute deviation percent was found to be around 3.18%. This approach can be of immense practical value for engineers and scientists for a quick estimation of acid dew point during combustion flue gas cooling for heat recovery and efficiency gain for wide range of operating conditions without the necessity of any pilot plant setup and tedious experimental trials. In particular, process and combustion engineers would find the tool to be user friendly involving transparent calculations with no complex expressions for their applications.
Woo, A H; Lindsay, R C
1980-07-01
A rapid quantiative method was developed for routine analysis of the major, even carbon-numbered free fatty acids in butter and cream. Free fatty acids were isolated directly from intact samples by a modified silicic acid-potassium hydroxide arrestant column and were separated by gas chromatography with a 1.8 m x 2 mm inner diameter glass column packed with 10% neopentyl glycol adipate on 80/100 Chromosorb W. Purified, formic acid-saturated carrier gas was required for minimal peak tailing and extended column life. The accuracy and reproducibility of the mmethod was established through quantitative recovery studies of free fatty acid mixtures, free fatty acids added to butter, and replicate analysis of butter and cream samples.
Iwakiri, Kentaro; Kobayashi, Akio; Seki, Masahiko; Ando, Yoshiyuki; Tsujio, Tadao; Hoshino, Masatoshi; Nakamura, Hiroaki
2017-11-15
MINI: Fourteen hundred consecutive patients were investigated for evaluating the utility of waterless hand rub before orthopaedic surgery. The risk in the surgical site infection incidence was the same, but costs of liquids used for hand hygiene were cheaper and the hand hygiene time was shorter for waterless protocol, compared with traditional hand scrub. A retrospective cohort study with prospectively collected data. The aim of this study was to compare SSI incidences, the cost of hand hygiene agents, and hand hygiene time between the traditional hand scrub and the waterless hand rub protocols before orthopedic surgery. Surgical site infections (SSI) prolong hospitalization and are a leading nosocomial cause of morbidity and a source of excess cost. Recently, a waterless hand rub protocol comprising alcohol based chlorhexidine gluconate for use before surgery was developed, but no studies have yet examined its utility in orthopedic surgery. Fourteen hundred consecutive patients who underwent orthopedic surgery (spine, joint replacement, hand, and trauma surgeries) in our hospital since April 1, 2012 were included. A total of 712 cases underwent following traditional hand scrub between April 1, 2012 and April 30, 2013 and 688 cases underwent following waterless hand rub between June 1, 2013 and April 30, 2014. We compared SSI incidences within all and each subcategory between two hand hygiene protocols. All patients were screened for SSI within 1 year after surgery. We compared the cost of hand hygiene agents and hand hygiene time between two groups. The SSI incidences were 1.3% (9 of 712) following the traditional protocol (2 deep and 7 superficial infections) and 1.1% (8 of 688) following the waterless protocol (all superficial infections). There were no significant differences between the two groups. The costs of liquids used for one hand hygiene were about $2 for traditional hand scrub and less than $1 for waterless hand rub. The mean hand hygiene time was 264
Energy Technology Data Exchange (ETDEWEB)
Mueller, H; Strauss, R; Hofmann, K -D; Suder, M; Hultsch, T; Wetzel, W; Gabrysch, H; Jung, J [Technische Hochschule, Zittau (German Democratic Republic)
1989-01-01
Explains the Zittau technology of combined flue gas heat recovery and flue gas desulfurization in small brown coal fired power plants. Steam generators to be equipped with this technology have 6.5 or 10 t/h steam capacity and are intended for combustion of low-grade brown coal (8.2 MJ/kg). An industrial 6.5 t/h prototype steam generator is in operation and it achieves 95% SO{sub 2} removal from flue gas with 5600 to 7800 mg SO{sub 2} per m{sup 3} of dry flue gas. The Zittau technology is available in 3 variants: with maximum waste heat recovery, with partial waste heat recovery or without waste heat recovery and only wet flue gas scrubbing. Two flowsheets of flue gas and suspension circulation are provided. The first variant recovers 25.7% of nominal heat capacity (1.1 thermal MW from a 4.2 MW steam generator with 6.5 t/h steam capacity), which amounts to economizing 2,400 t/a brown coal equivalent over 4,000 annual operating hours. The second variant recovers 6.5% of waste heat, requiring less investment by installing smaller heat exchangers than used in the first variant. All three variants have contact spray separators, suction units and suspension preparation equipment. Flue gas suspension scrubbing is carried out with fly ash produced by the steam generator. This ash is capable of absorbing 50 to 70% of flue gas SO{sub 2}. Supply of additional ash from other plants achieve a further 25% SO{sub 2} removal; a higher desulfurization degree is obtained by adding limestone to suspensions. 5 refs.
Hydrocarbon fuels from gas phase decarboxylation of hydrolyzed free fatty acid
Wang, Weicheng; Roberts, William L.; Stikeleather, Larry F.
2012-01-01
Gas phase decarboxylation of hydrolyzed free fatty acid (FFA) from canola oil has beeninvestigated in two fix-bed reactors by changing reaction parameters such as temperatures,FFA feed rates, and H 2-to-FFA molar ratios. FFA, which contains mostly C
Hsieh, Ching-Shui; Cheng, Hsiu-Chi; Lin, Jen-Shiou; Kuo, Shou-Jen; Chen, Yao-Li
2014-01-01
This trial was designed to compare the efficacy of 4% chlorhexidine gluconate (CHG) with normal saline (NS) as a predisinfection skin-scrub solution prior to standard presurgical skin preparation. Data was collected at a single transplantation center where patients electing resection of hepatic tumors were recruited between October 2011 and September 2012. In total, 100 patients were consecutively enrolled for random assignment to either 4% CHG or NS as a predisinfection skin-scrub solution prior to surgery. Our aim was to assess the comparative antiseptic efficacy of CHG in this setting, focusing on cutaneous microbial colonization (at baseline, preoperatively, and postoperatively) and postsurgical site infections as primary outcome measures. Positivity rates of baseline, preoperative, and postoperative cultures were similar for both groups, showing significant declines (relative to baseline) after skin preparation and no significant postsurgical rebound. Rates of surgical site infection were also similar in both groups (CHG, 6.0%; NS, 4.1%; P = 1.0). For patients with hepatic tumors undergoing hepatectomy, the effect of 4% CHG as a predisinfection scrub solution was similar to that of NS in terms of skin decontamination and surgical site infections.
[Determination a variety of acidic gas in air of workplace by Ion Chromatography].
Li, Shiyong
2014-10-01
To establish a method for determination of a variety of acid gas in the workplace air by Ion Chromatography. (hydrofluoric acid, hydrogen chloride or hydrochloric acid, sulfur anhydride or sulfuric acid, phosphoric acid, oxalic acid). The sample in workplace air was collected by the porous glass plate absorption tube containing 5 ml leacheate. (Sulfuric acid fog, phosphoric acid aerosol microporous membrane after collection, eluted with 5 ml of eluent.) To separated by AS14+AG14 chromatography column, by carbonate (2.0+1.0) mmol/L (Na(2)CO(3)-NaHCO(3)) as eluent, flow rate of 1 ml/min, then analyzed by electrical conductivity detector. The retain time was used for qualitative and the peak area was used for quantitation. The each ion of a variety of acid gas in the air of workplace were excellent in carbonate eluent separation. The linear range of working curve of 0∼20 mg/L. The correlation coefficient r>0.999; lower detection limit of 3.6∼115 µg/L; quantitative limit of 0.012∼0.53 mg/L; acquisition of 15L air were measured, the minimum detection concentration is 0.004 0∼0.13 mg/m(3). The recovery rate is 99.7%∼101.1%. In the sample without mutual interference ions. Samples stored at room temperature for 7 days. The same analysis method, the detection of various acidic gases in the air of workplace, simple operation, good separation effect, high sensitivity, high detection efficiency, easy popularization and application.
Uranium recovery from wet process phosphoric acid
International Nuclear Information System (INIS)
Carrington, O.F.; Pyrih, R.Z.; Rickard, R.S.
1981-01-01
Improvement in the process for recovering uranium from wetprocess phosphoric acid solution derived from the acidulation of uraniferous phosphate ores by the use of two ion exchange liquidliquid solvent extraction circuits in which in the first circuit (A) the uranium is reduced to the uranous form; (B) the uranous uranium is recovered by liquid-liquid solvent extraction using a mixture of mono- and di-(Alkyl-phenyl) esters of orthophosphoric acid as the ion exchange agent; and (C) the uranium oxidatively stripped from the agent with phosphoric acid containing an oxidizing agent to convert uranous to uranyl ions, and in the second circuit (D) recovering the uranyl uranium from the strip solution by liquid-liquid solvent extraction using di(2ethylhexyl)phosphoric acid in the presence of trioctylphosphine oxide as a synergist; (E) scrubbing the uranium loaded agent with water; (F) stripping the loaded agent with ammonium carbonate, and (G) calcining the formed ammonium uranyl carbonate to uranium oxide, the improvement comprising: (1) removing the organics from the raffinate of step (B) before recycling the raffinate to the wet-process plant, and returning the recovered organics to the circuit to substantially maintain the required balance between the mono and disubstituted esters; (2) using hydogren peroxide as the oxidizing agent in step (C); (3) using an alkali metal carbonate as the stripping agent in step (F) following by acidification of the strip solution with sulfuric acid; (4) using some of the acidified strip solution as the scrubbing agent in step (E) to remove phosphorus and other impurities; and (5) regenerating the alkali metal loaded agent from step (F) before recycling it to the second circuit
A novel decomposition technique of friable asbestos by CHClF2-decomposed acidic gas
International Nuclear Information System (INIS)
Yanagisawa, Kazumichi; Kozawa, Takahiro; Onda, Ayumu; Kanazawa, Masazumi; Shinohara, Junichi; Takanami, Tetsuro; Shiraishi, Masatsugu
2009-01-01
Asbestos was widely used in numerous materials and building products due to their desirable properties. It is, however, well known that asbestos inhalation causes health damage and its inexpensive decomposition technique is necessary to be developed for pollution prevention. We report here an innovative decomposition technique of friable asbestos by acidic gas (HF and HCl) generated from the decomposition of CHClF 2 by the reaction with superheated steam at 800 deg. C. Chrysotile-asbestos fibers were completely decomposed to sellaite and magnesium silicofluoride hexahydrate by the reaction with CHClF 2 -decomposed acidic gas at 150 deg. C for 30 min. At high temperatures beyond 400 deg. C, sellaite and hematite were detected in the decomposed product. In addition, crocidolite containing wastes and amosite containing wastes were decomposed at 500 deg. C and 600 deg. C for 30 min, respectively, by CHClF 2 -decomposed acidic gas. The observation of the reaction products by phase-contrast microscopy (PCM) and scanning electron microscopy (SEM) confirmed that the resulting products did not contain any asbestos
Paris, Daniel H; Blacksell, Stuart D; Nawtaisong, Pruksa; Jenjaroen, Kemajittra; Teeraratkul, Achara; Chierakul, Wirongrong; Wuthiekanun, Vanaporn; Kantipong, Pacharee; Day, Nicholas P J
2011-09-01
There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.
Sacral Herpes Zoster Associated with Voiding Dysfunction in a Young Patient with Scrub Typhus.
Hur, Jian
2015-06-01
When a patient presents with acute voiding dysfunction without a typical skin rash, it may be difficult to make a diagnosis of herpes zoster. Here, we present a case of scrub typhus in a 25-year-old man with the complication of urinary dysfunction. The patient complained of loss of urinary voiding sensation and constipation. After eight days, he had typical herpes zoster eruptions on the sacral dermatomes and hypalgesia of the S1-S5 dermatomes. No cases of dual infection with varicella zoster virus and Orientia tsutsugamushi were found in the literature. In the described case, scrub typhus probably induced sufficient stress to reactivate the varicella zoster virus. Early recognition of this problem is imperative for prompt and appropriate management, as misdiagnosis can lead to long-term urinary dysfunction. It is important that a diagnosis of herpes zoster be considered, especially in patients with sudden onset urinary retention.
Ahmad, S; Dhar, M; Mittal, G; Bhat, N K; Shirazi, N; Kalra, V; Sati, H C; Gupta, V
2016-04-01
Positive serology for dengue and/or scrub typhus infection with/without positive malarial smear (designated as mixed or co-infection) is being increasingly observed during epidemics of acute undifferentiated febrile illnesses (AUFIs). We planned to study the clinical and biochemical spectrum of co-infections with Plasmodium sp., dengue virus and scrub typhus and compare these with mono-infection by the same organisms. During the period from December 2012 to December 2013, all cases presenting with AUFIs to a single medical unit of a referral centre in Garhwal region of the north Indian state of Uttarakhand were retrospectively selected and categorised aetiologically as co-infections, malaria, dengue or scrub typhus. The groups thus created were compared in terms of demographic, clinical, biochemical and outcome parameters. The co-infection group (n = 49) was associated with milder clinical manifestations, fewer, milder and non-progressive organ dysfunction, and lesser need for intensive care, mechanical ventilation and dialysis as compared to mono-infections. When co-infections were sub-grouped and compared with the relevant mono-infections, there were differences in certain haematological and biochemical parameters; however, this difference did not translate into differential outcomes. Scrub typhus mono-infection was associated with severe disease in terms of both morbidity and mortality. Malaria, dengue and scrub typhus should be routinely tested in all patients with AUFIs. Co-infections, whether true or due to serological cross-reactivity, appear to be a separate entity so far as presentation and morbidity is concerned. Further insight is needed into the mechanism and identification of the protective infection.
Estimation of Fatty Acids in Corn Oil by Gas Capillary Chromatography
International Nuclear Information System (INIS)
Kamal, Mohammad A; Klein Peter
2007-01-01
Fatty acids provide energy as well as play important role in some cellular structures like cell membrane and certain hormones. Saturated fatty acids are usually found in animal products and in some vegetable oils as well. These saturated fatty acids may be a factor in weight gain and obesity but eating them in moderate amounts may not be damaging to health of every person. Monounsaturated fatty acids can lower blood levels of low density lipoprotein cholesterol and have potential to increase blood levels of high density lipoprotein cholesterol and by this way plays protective role against heart disease. The omega 3 and 6 fatty acids have vital roles in many biological systems such as nervous, immune, cardiovascular, dermal and vision systems. Therefore, it is essential to optimize the instrumental conditions and column specification for the estimation of various fatty acids in the oil, which was considered in the current study using Gas Capillary Chromatography. (author)
Q Fever, Scrub Typhus, and Rickettsial Diseases in Children, Kenya, 2011-2012.
Maina, Alice N; Farris, Christina M; Odhiambo, Antony; Jiang, Ju; Laktabai, Jeremiah; Armstrong, Janice; Holland, Thomas; Richards, Allen L; O'Meara, Wendy P
2016-05-01
To increase knowledge of undifferentiated fevers in Kenya, we tested paired serum samples from febrile children in western Kenya for antibodies against pathogens increasingly recognized to cause febrile illness in Africa. Of patients assessed, 8.9%, 22.4%, 1.1%, and 3.6% had enhanced seroreactivity to Coxiella burnetii, spotted fever group rickettsiae, typhus group rickettsiae, and scrub typhus group orientiae, respectively.
Regeneration of an aqueous solution from an acid gas absorption process by matrix stripping
Rochelle, Gary T [Austin, TX; Oyenekan, Babatunde A [Katy, TX
2011-03-08
Carbon dioxide and other acid gases are removed from gaseous streams using aqueous absorption and stripping processes. By replacing the conventional stripper used to regenerate the aqueous solvent and capture the acid gas with a matrix stripping configuration, less energy is consumed. The matrix stripping configuration uses two or more reboiled strippers at different pressures. The rich feed from the absorption equipment is split among the strippers, and partially regenerated solvent from the highest pressure stripper flows to the middle of sequentially lower pressure strippers in a "matrix" pattern. By selecting certain parameters of the matrix stripping configuration such that the total energy required by the strippers to achieve a desired percentage of acid gas removal from the gaseous stream is minimized, further energy savings can be realized.
Status of radioiodine control for nuclear fuel reprocessing plants
International Nuclear Information System (INIS)
Burger, L.L.; Scheele, R.D.
1983-07-01
This report summarizes the status of radioiodine control in a nuclear fuel reprocessing plant with respect to capture, fixation, and disposal. Where possible, we refer the reader to a number of survey documents which have been published in the last four years. We provide updates where necessary. Also discussed are factors which must be considered in developing criteria for iodine control. For capture from gas streams, silver mordenite and a silver nitrate impregnated silica (AC-6120) are considered state-of-the-art and are recommended. Three aqueous scrubbing processes have been demonstrated: Caustic scrubbing is simple but probably will not give an adequate iodine retention by itself. Mercurex (mercuric nitrate-nitric acid scrubbing) has a number of disadvantages including the use of toxic mercury. Iodox (hyperazeotropic nitric acid scrubbing) is effective but employs a very corrosive and hazardous material. Other technologies have been tested but require extensive development. The waste forms recommended for long-term storage or disposal are silver iodide, the iodates of barium, strontium, or calcium, and silver loaded sorbents, all fixed in cement. Copper iodide in bitumen (asphalt) is a possibility but requires testing. The selection of a specific form will be influenced by the capture process used
Ammonia Gas Sensing Behavior of Tanninsulfonic Acid Doped Polyaniline-TiO2 Composite
Directory of Open Access Journals (Sweden)
Venu Gopal Bairi
2015-10-01
Full Text Available A highly active tannin doped polyaniline-TiO2 composite ammonia gas sensor was developed and the mechanism behind the gas sensing activity was reported for the first time. A tanninsulfonic acid doped polyaniline (TANIPANI-titanium dioxide nanocomposite was synthesized by an in situ polymerization of aniline in the presence of tanninsulfonic acid and titanium dioxide nanoparticles. X-ray diffraction and thermogravimetric analysis were utilized to determine the incorporation of TiO2 in TANIPANI matrix. UV-Visible and infrared spectroscopy studies provided information about the electronic interactions among tannin, polyaniline, and TiO2. Scanning electron microscopy (SEM along with energy dispersive X-ray spectroscopy (EDS and atomic force microscopy (AFM surface analysis techniques were used to investigate the metal oxide dispersions inside polyaniline matrix. Gas sensors were prepared by spin coating solutions of TANIPANI-TiO2 and TANIPANI composites onto glass slides. Sensors were tested at three different concentrations (20 ppm, 40 ppm, and 60 ppm of ammonia gas at ambient temperature conditions by measuring the changes in surface resistivity of the films with respect to time. Ammonia gas sensing plots are presented showing the response values, response times and recovery times. The TANIPANI-TiO2 composite exhibited better response and shorter recovery times when compared to TANIPANI control and other polyaniline composites that have been reported in the literature. For the first time a proposed mechanism of gas sensing basing on the polaron band localization and its effects on the gas sensing behavior of polyaniline are reported.
Thipmontree, Wilawan; Tantibhedhyangkul, Wiwit; Silpasakorn, Saowaluk; Wongsawat, Ekkarat; Waywa, Duangdao; Suputtamongkol, Yupin
2016-10-05
Scrub typhus is endemic in Thailand. Of the 495 patients with acute undifferentiated fever studied in Maharat Nakhon Ratchasima Hospital, Nakhon Ratchasima, Thailand, from June 1, 2011, to December 31, 2012, 146 patients (29.5%) had confirmed scrub typhus. The majority of cases were male, farmers, with the mean (±standard deviation) age of 54.1 ± 15.2 years. A total of 59 patients (40.4%) had eschar lesion. The commonest sites for an eschar in male patients were the perineum, inguinal, and buttock area; whereas in females, it was the head and neck area. Abnormal electrocardiogram was found in 39 of 79 patients (49.4%) with sinus tachycardia being the most frequent finding (17, 21.5%). A total of 73 patients (50%) had at least one complication. Myocarditis was the cause of complete heart block in a scrub typhus patient, and he fully recovered after receiving intravenous chloramphenicol treatment. The case fatality rate was 6.2% (nine deaths).The independent predictors for fatal outcome were age over 65 years (odds ratio [OR] = 14.49, 95% confidence interval [CI] = 1.26-166.44, P = 0.03), acute kidney injury (OR = 12.75, 95% CI = 1.77-92.07, P = 0.01), and hyperbilirubinemia (OR = 24.82, 95% CI = 2.12-286.61, P = 0.01). Early diagnosis and prompt appropriate treatment can improve the patient's outcome. © The American Society of Tropical Medicine and Hygiene.
Otterdal, Kari; Janardhanan, Jeshina; Astrup, Elisabeth; Ueland, Thor; Prakash, John A J; Lekva, Tove; Abraham, O C; Thomas, Kurien; Damås, Jan Kristian; Mathews, Prasad; Mathai, Dilip; Aukrust, Pål; Varghese, George M
2014-11-01
Scrub typhus is endemic in the Asia-Pacific region. Mortality is high even with treatment, and further knowledge of the immune response during this infection is needed. This study was aimed at comparing plasma levels of monocyte/macrophage and endothelial related inflammatory markers in patients and controls in South India and to explore a possible correlation to disease severity and clinical outcome. Plasma levels of ALCAM, VCAM-1, sCD163, sCD14, YKL-40 and MIF were measured in scrub typhus patients (n = 129), healthy controls (n = 31) and in infectious disease controls (n = 31), both in the acute phase and after recovery, by enzyme immunoassays. Patients had markedly elevated levels of all mediators in the acute phase, differing from both healthy and infectious disease controls. During follow-up levels of ALCAM, VCAM-1, sCD14 and YKL-40 remained elevated compared to levels in healthy controls. High plasma ALCAM, VCAM-1, sCD163, sCD14, and MIF, and in particular YKL-40 were all associated with disease severity and ALCAM, sCD163, MIF and especially YKL-40, were associated with mortality. Our findings show that scrub typhus is characterized by elevated levels of monocyte/macrophage and endothelial related markers. These inflammatory markers, and in particular YKL-40, may contribute to disease severity and clinical outcome. Copyright © 2014 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Measurements of atmospheric nitrous acid and nitric acid
Energy Technology Data Exchange (ETDEWEB)
Huang, G.; Deng, G. [State University of New York (United States). School of Public Health; Zhou, X. [State University of New York (United States). School of Public Health; New York State Dept. of Health (United States). Wadsworth Center; Qiao, H.; Civerolo, K. [New York State Dept. of Health (United States). Wadsworth Center
2002-05-01
A highly sensitive technique for the measurement of atmospheric HONO and HNO{sub 3} is reported. The technique is based on aqueous scrubbing using two coil samplers, followed by conversion of HNO{sub 3} to nitrite, derivatization of nitrite to a highly light-absorbing azo dye with sulfanilamide (SA) and N-(1-naphthyl) ethylenediamine (NED), and high performance liquid chromatography (HPLC) analysis. HNO{sub 3} concentration was obtained by the difference of the two channels. Two scrubbing solutions were used for sampling the two species: a 1-mM phosphate buffer solution (pH 7) for the measurement of HONO and a 180 mM NH{sub 4}Cl/NH{sub 3} buffer solution (pH 8.5) for the measurement of HONO+HNO{sub 3}. The scrubbing solution flow rate was 0.24 ml min{sup -1} and the gas sampling flow rate was 2l min{sup -1}. HNO{sub 3} in the NH{sub 4}Cl/NH{sub 3} buffer solution was quantitatively reduced to nitrite along an on-line 0.8-cm Cd reductor column. Nitrite in both channels was derivatized with 2 mM SA and 0.2 mM NED in 25 mM HCl. Quantitative derivatization was achieved within 5 min at 55{sup o}C. The azo dye derivative was then separated from the SA/NED reagent by reversed-phase HPLC and detected with a UV-vis detector at 540 nm. With an on-line SEP-PAK C-18 cartridge for the reagent purification, the method detection limit is estimated to be better than 1 pptv for HONO and about 20 pptv for HNO{sub 3}. The sample integration time was about 2 min and the sampling frequency is every 10 min. Data collected in downtown Albany and Whiteface Mountain, NY, are shown as examples of applications of this technique in both urban and remote clean environments. (Author)
Short-period volcanic gas precursors to phreatic eruptions: Insights from Poás Volcano, Costa Rica
de Moor, Maarten; Aiuppa, Alessandro; Pacheco, Javier; Avard, Geoffroy; Kern, Christoph; Liuzzo, Marco; Martinez, Maria; Giudice, Gaetano; Fischer, Tobias P.
2016-01-01
Volcanic eruptions involving interaction with water are amongst the most violent and unpredictable geologic phenomena on Earth. Phreatic eruptions are exceptionally difficult to forecast by traditional geophysical techniques. Here we report on short-term precursory variations in gas emissions related to phreatic blasts at Poás volcano, Costa Rica, as measured with an in situ multiple gas analyzer that was deployed at the edge of the erupting lake. Gas emitted from this hyper-acid crater lake approaches magmatic values of SO2/CO2 1–6 days prior to eruption. The SO2 flux derived from magmatic degassing through the lake is measureable by differential optical absorption spectrometry (sporadic campaign measurements), which allows us to constrain lake gas output and input for the major gas species during eruptive and non-eruptive periods. We can further calculate power supply to the hydrothermal system using volatile mass balance and thermodynamics, which indicates that the magmatic heat flux into the shallow hydrothermal system increases from ∼27 MW during quiescence to ∼59 MW during periods of phreatic events. These transient pulses of gas and heat from the deeper magmatic system generate both phreatic eruptions and the observed short-term changes in gas composition, because at high gas flux scrubbing of sulfur by the hydrothermal system is both kinetically and thermodynamically inhibited whereas CO2gas is always essentially inert in hyperacid conditions. Thus, the SO2/CO2 of lake emissions approaches magmatic values as gas and power supply to the sub-limnic hydrothermal system increase, vaporizing fluids and priming the hydrothermal system for eruption. Our results suggest that high-frequency real-time gas monitoring could provide useful short-term eruptive precursors at volcanoes prone to phreatic explosions.
Scrub typhus: risks, diagnostic issues, and management challenges
Directory of Open Access Journals (Sweden)
Prakash JAJ
2017-08-01
Full Text Available John Antony Jude Prakash Department of Clinical Microbiology, Christian Medical College, Vellore, Tamil Nadu, India Abstract: Scrub typhus is an acute febrile illness in the “tsutsugamushi triangle”, transmitted by chiggers that can be treated effectively if detected early. Laboratory testing, including molecular and serological assays, is needed for confirming the diagnosis, especially in the absence of the pathognomonic eschar. In this review, factors that play a role in disease occurrence and clinical clues for diagnosis, in addition to risk factors contributing to disease severity, including mortality, are discussed in detail. Moreover, issues related to diagnostic assays, treatment, and mixed infections are also enumerated and described. Keywords: Orientia tsutsugamushi, disease severity, mortality predictors, diagnosis, coinfections, treatment
DEFF Research Database (Denmark)
Poulsen, Nina Aagaard; Eskildsen, Carl Emil; Skov, T.
or on fatty acids data measured from gas chromatography in 371 Danish Holstein cows. Results showed similar heritability estimates and strong genomic correlations for most of the fatty acids. However, for some fatty acids, the choice of data affected the genetic parameter estimation, which may be due...
Effect of sublethal gamma radiation on host defenses in experimental scrub typhus
International Nuclear Information System (INIS)
Kelly, D.J.; Rees, J.C.
1986-01-01
The effect of sublethal gamma radiation on inbred mice chronically infected with scrub typhus rickettsiae was examined. Inbred mice which were inoculated with the Gilliam or Karp strain of Rickettsia tsutsugamushi by the subcutaneous route harbored the infection for at least 1 year. Irradiation of these animals at 12 or 52 weeks postinoculation with normally sublethal levels induced a significantly higher percentage of rickettsemic mice (recrudescence) than was seen in the unirradiated, similarly infected control animals. In addition, sublethal irradiation at 12 weeks induced a quantitative increase in total rickettsiae. Homologous antibody titers to the rickettsiae were examined for 5 weeks after irradiation to determine the role of the humoral response in radiation-induced recrudescence. Unirradiated, infected mice showed consistent titers of about 320 throughout the 5-week observation period, and the titer was not affected by exposure of up to 500 rads of gamma radiation. Drug dose-dependent radioprotection and modification of recrudescence was noted in infected, irradiated mice treated with the antiradiation compound S-2-(3-aminopropylamino)ethyl phosphorothioic acid. The results of this investigation supported the conclusion that the recrudescence of a chronic rickettsial infection in the appropriate host after immunological impairment due to gamma radiation can result in an acute, possibly lethal rickettsemia
Paris, D. H.; Chansamouth, V.; Nawtaisong, P.; Löwenberg, E. C.; Phetsouvanh, R.; Blacksell, S. D.; Lee, S. J.; Dondorp, A. M.; van der Poll, T.; Newton, P. N.; Levi, M. [=Marcel M.; Day, N. P. J.
2012-01-01
Scrub typhus (caused by Orientia tsutsugamushi) and murine typhus (caused by Rickettsia typhi) cause up to 28% of febrile episodes in Thailand and Laos. The current understanding of coagulation and inflammation in the pathogenesis of these clinically very similar vasculotropic diseases is limited.
2010-09-01
Korean J Paras/to/. Vol. 48, No. 3: 237-243, September 2010 DOl: JO.J3471kjp.2010.48.J.237 Serosurveillance of Scrub Typhus in Small Mammals...65th Medical BrigadeAJSAMEDDAC-Korea, Unit# 15281, APO AP 96205-5281, USA Abstract: Comprehensive quarterly serosurveillance on scrub typhus in small...rarely observed (prevalence < 1 0%). In contrast to previous surveys, higher chigger indices of the primary scrub typhus vectors, L. pallidum (165.4
Energy Technology Data Exchange (ETDEWEB)
Derichs, W.; Menden, W.; Ebel, P.K. (RWE Energie AG, Bergheim (Germany))
1991-10-01
Until now, the well-known measuring systems for determining acid dewpoint have been applied primarily to flue gases from oil-fired combustion. Using an acid dewpoint measuring system which has now been available on the market for some time, it is possible to measure the acid dewpoint reliably and continuously in flue gas from coal-fired combustion, with low SO[sub 3] concentrations. This measuring system has also been used for flue gas from which the dust and sulphur have been removed as well as for untreated flue gas of conventional combustion systems with gas, oil, hard coal and brown coal firing and also in fluidized bed combustion systems. 6 refs., 11 figs., 2 tabs.
Review and assessment of pool scrubbing models
International Nuclear Information System (INIS)
Herranz, L.E.; Escudero, M.J.; Peyres, V.; Polo, J.; Lopez-Jimenez, J.
1996-01-01
Decontamination of fission products bearing bubbles as they through aqueous pools becomes a crucial phenomenon for source term evaluation of hypothetical risk dominant sequences of Light Water Reactors. In the present report a peer review and assessment of models encapsulated in SPARC andBUSCA codes is presented. Several aspects of pool scrubbing have been addressed: particle removal, fission product vapour retention and bubble hydrodynamics. Particular emphasis has been given to the close link between retention and hydrodynamics, from both modelling and experimental point of view. In addition, RHR and SGTR sequences were simulated with SPARC90 and BUSCA-AUG92 codes, and their results were compared with those obtained with MAAP 3.0B.As a result of this work, model capabilities and shortcomings have beenassessed and some areas susceptible of further research have been identified.(Author) 73 refs
Review and assessment of pool scrubbing models
International Nuclear Information System (INIS)
Herranz, L.E.; Escudero, M.J.; Peyres, V.; Polo, J.; Lopez, J.
1996-01-01
Decontamination of fission products bearing bubbles as they pass through aqueous pools becomes a crucial phenomenon for source term evaluation of hypothetical risk dominant sequences of Light Water Reactors. In the present report a peer review and assessment of models encapsulated in SPARC and BUSCA codes is presented. Several aspects of pool scrubbing have been addressed: particle removal, fission product vapour retention and bubble hydrodynamics. Particular emphasis has been given to the close link between retention and hydrodynamics, from both modelling and experimental point of view. In addition, RHR and SGTR sequences were simulated with SPARC90 and BUSCA-AUG92 codes, and their results were compared with those obtained with MAAP 3.0B. As a result of this work, model capabilities and shortcomings have been assessed and some areas susceptible of further research have been identified. (Author) 73 refs
Review and assessment of pool scrubbing models
Energy Technology Data Exchange (ETDEWEB)
Herranz, L.E.; Escudero, M.J.; Peyres, V.; Polo, J.; Lopez, J.
1996-07-01
Decontamination of fission products bearing bubbles as they pass through aqueous pools becomes a crucial phenomenon for source term evaluation of hypothetical risk dominant sequences of Light Water Reactors. In the present report a peer review and assessment of models encapsulated in SPARC and BUSCA codes is presented. Several aspects of pool scrubbing have been addressed: particle removal, fission product vapour retention and bubble hydrodynamics. Particular emphasis has been given to the close link between retention and hydrodynamics, from both modelling and experimental point of view. In addition, RHR and SGTR sequences were simulated with SPARC90 and BUSCA-AUG92 codes, and their results were compared with those obtained with MAAP 3.0B. As a result of this work, model capabilities and shortcomings have been assessed and some areas susceptible of further research have been identified. (Author) 73 refs.
Limiting Current of Oxygen Reduction on Gas-Diffusion Electrodes for Phosphoric Acid Fuel Cells
DEFF Research Database (Denmark)
Li, Qingfeng; Gang, Xiao; Hjuler, Hans Aage
1994-01-01
on polytetrafluorine-ethyl bonded gas-diffusion electordes in phosphoric acid with and without fluorinated additives. This provides an alternative to estimate the film thickness by combining it with the acid-adsorption measurements and the porosity analysis of the catalyst layer. It was noticed that the limiting......Various models have been devoted to the operation mechanism of porous diffusion electrodes. They are, however, suffering from the lack of accuracy concerning the acid-film thickness on which they are based. In the present paper the limiting current density has been measured for oxygen reduction...... current density can be accomplished either by gas-phase diffusion or liquid-phase diffusion, and it is the latter that can be used in the film-thickness estimation. It is also important to mention that at such a limiting condition, both the thin-film model and the filmed agglomerate model reach the same...
International Nuclear Information System (INIS)
Gawlowska, W.; Nowak, M.
1978-01-01
Radiolytically degraded TBP-n-paraffins solvent was used in the laboratory flow-sheet to study the influence of radiation exposure on decontamination of uranium. The influence of accumulated doses on extraction, scrubbing and stripping of uranium and some fission products has been discussed. (author)
Identification of bound alcohols in soil humic acids by gas chromatography-mass spectrometry
Berthier , Gersende; Dou , Sen; Peakman , Torren; Lichtfouse , Eric
2000-01-01
International audience; Humic acids are complex, partly macromolecular, yellow-brownish substances occurring in soils, waters and sediments. In order to shed some light on their molecular structure, crop humic acids were cleaved by alkaline hydrolysis (KOH). The products were fractionated by thin layer chromatography to give mono-alcohols which were analysed as acetate derivatives by gas chromatography coupled to mass spectrometry. Linear alcohols, sterols, stanols and plant-derived triterpen...
Rondo, L.; Kürten, A.; Adamov, A.; Bianchi, F.; Breitenlechner, M.; Duplissy, J.; Franchin, A.; Dommen, J.; Donahue, N. M.; Dunne, E. M.; Flagan, R. C.; Hakala, J.; Hansel, A.; Keskinen, H.; Kim, J.; Jokinen, T.; Lehtipalo, K.; Leiminger, M.; Praplan, A.; Riccobono, F.; Rissanen, M. P.; Sarnela, N.; Schobesberger, S.; Simon, M.; Sipilä, M.; Smith, J. N.; Tomé, A.; Tröstl, J.; Tsagkogeorgas, G.; Vaattovaara, P.; Winkler, P. M.; Williamson, C.; Wimmer, D.; Baltensperger, U.; Kirkby, J.; Kulmala, M.; Petäjä, T.; Worsnop, D. R.; Curtius, J.
2016-01-01
Sulfuric acid is widely recognized as a very important substance driving atmospheric aerosolnucleation. Based on quantum chemical calculations it has been suggested that the quantitative detectionof gas phase sulfuric acid (H2SO4) by use of Chemical Ionization Mass Spectrometry (CIMS) could be biased inthe presence of gas phase amines such as dimethylamine (DMA). An experiment (CLOUD7 campaign) was setup at the CLOUD (Cosmics Leaving OUtdoor Droplets) chamber to investigate the quantitative detection ofH2SO4in the presence of dimethylamine by CIMS at atmospherically relevant concentrations. For the first time inthe CLOUD experiment, the monomer sulfuric acid concentration was measured by a CIMS and by two CI-APi-TOF(Chemical Ionization-Atmospheric Pressure interface-Time Of Flight) mass spectrometers. In addition, neutralsulfuric acid clusters were measured with the CI-APi-TOFs. The CLOUD7 measurements show that in the presenceof dimethylamine (<5 to 70 pptv) the sulfuric acid monomer measured by the CIMS...
Directory of Open Access Journals (Sweden)
Hu Sung-Yuan
2011-03-01
Full Text Available Abstract Background Scrub typhus, a mite-transmitted zoonosis caused by Orientia tsutsugamushi, is an endemic disease in Taiwan and may be potentially fatal if diagnosis is delayed. Case presentations We encountered a 23-year-old previously healthy Taiwanese male soldier presenting with the right ear pain after training in the jungle and an eleven-day history of intermittent high fever up to 39°C. Amoxicillin/clavulanate was prescribed for otitis media at a local clinic. Skin rash over whole body and abdominal cramping pain with watery diarrhea appeared on the sixth day of fever. He was referred due to progressive dyspnea and cough for 4 days prior to admission in our institution. On physical examination, there were cardiopulmonary distress, icteric sclera, an eschar in the right external auditory canal and bilateral basal rales. Laboratory evaluation revealed thrombocytopenia, elevation of liver function and acute renal failure. Chest x-ray revealed bilateral diffuse infiltration. Doxycycline was prescribed for scrub typhus with acute respiratory distress syndrome and multiple organ failure. Fever subsided dramatically the next day and he was discharged on day 7 with oral tetracycline for 7 days. Conclusion Scrub typhus should be considered in acutely febrile patients with multiple organ involvement, particularly if there is an eschar or a history of environmental exposure in endemic areas. Rapid and accurate diagnosis, timely administration of antibiotics and intensive supportive care are necessary to decrease mortality of serious complications of scrub typhus.
SO3 tinges stack gas from scrubbed coal-fired units
International Nuclear Information System (INIS)
Jones, C.; Ellison, W.
1998-01-01
The small amount of SO 3 in flue gas creates enough problems inside the plant. New US EPA regulations on so-called air toxics are making SO 3 discharge an emission problem as well - and a visible one at that. Units that have installed wet scrubbers to control SO 2 emissions may be most affected. The article explains that SO 3 levels in coal-fired power plants are mainly increased by catalytic oxidation of SO 2 by iron oxide on the fireside surfaces of the superheater tubes. Dependence on air-heater temperature is discussed. Wet FGD systems are responsible for the formation of 'blue eye' where SO 3 causes a blue hue in the plume. Ammonia injection has been effective in reducing SO 3 vapour, as has injecting water ahead of the electrostatic precipitator. Replacement of a wet ESP with a dry ESP is also a solution. 2 figs
Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent
Energy Technology Data Exchange (ETDEWEB)
Washington, A. L. II [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
2014-03-03
This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tank 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or DCs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction DCs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material.
Directory of Open Access Journals (Sweden)
Christian A Keller
2014-08-01
Full Text Available Central aspects in the pathogenesis of scrub typhus, an infection caused by Orientia (O. tsutsugamushi, have remained obscure. Its organ and cellular tropism are poorly understood. The purpose of this study was to analyze the kinetics of bacterial dissemination and associated inflammatory responses in infected tissues in an experimental scrub typhus mouse model, following infection with the human pathogenic strain Karp. We provide a thorough analysis of O. tsutsugamushi infection in inbred Balb/c mice using footpad inoculation, which is close to the natural way of infection. By a novel, highly sensitive qPCR targeting the multi copy traD genes, we quantitatively monitored the spread of O. tsutsugamushi Karp from the skin inoculation site via the regional lymph node to the internal target organs. The highest bacterial loads were measured in the lung. Using confocal imaging, we also detected O. tsutsugamushi at the single cell level in the lung and found a predominant macrophage rather than endothelial localization. Immunohistochemical analysis of infiltrates in lung and brain revealed differently composed lesions with specific localizations: iNOS-expressing macrophages were frequent in infiltrative parenchymal noduli, but uncommon in perivascular lesions within these organs. Quantitative analysis of the macrophage response by immunohistochemistry in liver, heart, lung and brain demonstrated an early onset of macrophage activation in the liver. Serum levels of interferon (IFN-γ were increased during the acute infection, and we showed that IFN-γ contributed to iNOS-dependent bacterial growth control. Our data show that upon inoculation to the skin, O. tsutsugamushi spreads systemically to a large number of organs and gives rise to organ-specific inflammation patterns. The findings suggest an essential role for the lung in the pathogenesis of scrub typhus. The model will allow detailed studies on host-pathogen interaction and provide further
Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent
International Nuclear Information System (INIS)
Washington, A. L. II; Peters, T. B.
2014-01-01
This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tank 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or DCs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction DCs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material
POSSIBILITY OF BENEFICIATION OF SILICA SAND FROM THE CROATIAN DEPOSITS USING ATTRITION SCRUBBING
Directory of Open Access Journals (Sweden)
Ivan Sobota
2011-12-01
Full Text Available To meet high quality requirements defined for specific industrial applications, the raw sand often has to be subjected to extensive physical and chemical processing. The possibility of achieving silica sand concentrate of required quality depends mostly on raw sand properties, primarily mineral impurity types and contents, and features of applied beneficiation methods. When the impurities occur in the form of oxide coatings on the surfaces of the single sand grains, attriton scrubbing is applied. By reducing the proportion of oxide coatings on the grains, the quality of sand can be improved. With the aim to determine the possibilities of the beneficiation of silica sand from significant Croatian deposits (“Vrtlinska”, “Štefanac” and “Španovica” and achieve concentrate grade complying with the requirements of domestic industry, laboratory tests were conducted on three raw sand samples with different SiO2 and impurity contents. Grain size distribution, chemical and mineral composition of raw sand samples, and the possibility of their quality improvement by applying the washing, classification and attrition scrubbing were defined by analysis of test results (the paper is published in Croatian.
Ding, H.; Valentine, D.
2005-12-01
To study the microbial community in a Southern California seep field, sediment and bacterial mat samples were collected from natural gas-bearing and gas-free surfaces at two distinct seeps in the Coal Oil Point seep field, offshore Santa Barbara. Fatty acids in these samples were extracted, analyzed and identified. Using gas chromatography (GC), more than 30 different fatty acids were separated. Generally, fatty acid concentrations in natural gas-bearing samples were about 5-fold higher compared to gas-free samples. Using gas chromatography mass sepctrometry (GC-MS), all separated fatty acids were identified in each sample. The major constituents included saturated 14:0, 16:0, 18:0, branched i-15, a-15 and unsaturated 16:1 and 18:1 series fatty acids. GC-IRMS (isotope ratio mass spectrometry) analysis provided the 13C of all major fatty acids and some 16:1 series fatty acids were found to be more depleted than -40% in samples associated with gas seepage. After treatment with dimethyl disufide (DMDS), the 16:1 series fatty acids were resolved into five distinct components, including common composition 16:1(7), bacterial specific i-16:1(7) and typical biomarkers of type I methnotrophs 16:1(8), 16(6) and 16:1(5), suggesting an important role for methnotrophs in seep sediments and microbial mats. These results provide evidence for the activity of type I methanotrophic bacteria in microbial mats and surficial sediments at the Coal Oil Point seep field, and have implications for methane cycling in this and other seep
Sunyakumthorn, Piyanate; Somponpun, Suwit J.; Im-erbsin, Rawiwan; Anantatat, Tippawan; Jenjaroen, Kemajittra; Dunachie, Susanna J.; Lombardini, Eric D.; Burke, Robin L.; Blacksell, Stuart D.; Jones, James W.; Mason, Carl J.; Richards, Allen L.; Day, Nicholas P. J.
2018-01-01
Background Scrub typhus is an important endemic disease in tropical Asia caused by Orientia tsutsugamushi for which no effective broadly protective vaccine is available. The successful evaluation of vaccine candidates requires well-characterized animal models and a better understanding of the immune response against O. tsutsugamushi. While many animal species have been used to study host immunity and vaccine responses in scrub typhus, only limited data exists in non-human primate (NHP) models. Methodology/Principle findings In this study we evaluated a NHP scrub typhus disease model based on intradermal inoculation of O. tsutsugamushi Karp strain in rhesus macaques (n = 7). After an intradermal inoculation with 106 murine LD50 of O. tsutsugamushi at the anterior thigh (n = 4) or mock inoculum (n = 3), a series of time course investigations involving hematological, biochemical, molecular and immunological assays were performed, until day 28, when tissues were collected for pathology and immunohistochemistry. In all NHPs with O. tsutsugamushi inoculation, but not with mock inoculation, the development of a classic eschar with central necrosis, regional lymphadenopathy, and elevation of body temperature was observed on days 7–21 post inoculation (pi); bacteremia was detected by qPCR on days 6–18 pi; and alteration of liver enzyme function and increase of white blood cells on day 14 pi. Immune assays demonstrated raised serum levels of soluble cell adhesion molecules, anti-O. tsutsugamushi-specific antibody responses (IgM and IgG) and pathogen-specific cell-mediated immune responses in inoculated macaques. The qPCR assays detected O. tsutsugamushi in eschar, spleen, draining and non-draining lymph nodes, and immuno-double staining demonstrated intracellular O. tsutsugamushi in antigen presenting cells of eschars and lymph nodes. Conclusions/Significance These data show the potential of using rhesus macaques as a scrub typhus model, for evaluation of correlates of
Breininger, David R.
2018-01-01
Florida scrub-jays are a species listed under the Endangered Species Act. The NASA Ecology program has been a partner for conservation, recovery, and translocation across the species range. The objectives of this talk are to update members of the Archie Carr Working Group recovery, conservation, and translocation activities and describe how the Archie Carr National Wildlife Refuge and nearby conservation lands relate to species recovery actions.
Technologies and policies for "hard to scrub" emissions sources
Friedmann, J.
2016-12-01
The science of climate change yields harsh math regarding atmospheric accumulations of GHGs. The world is far from target trajectories for 2C or 1.5C, and the global carbon budget is severe. To achieve those targets requires two things. First, we must field technologies that reduce emissions from the "hard to scrub" parts of the US and global economies, such as heavy industry (cement and steel), aviation, ocean shipping, and household cooking and heating. Second, we will likely need negative emissions pathways for those sources that prove extremely difficult to remove or reduce - the climate equivalent of adding revenue to one's budget. Such pathways may well need to convert GHG emissions (especially CO2 and methane) into useful products with minimal infrastructure builds. Dramatic advances in advanced manufacturing, 3D printing, simulation, modeling, and data analytics have made possible solutions which were previously unthinkable or impossible. This include "bespoke reactors", which can simultaneously perform separations and conversions; low-cost modular chemical systems of any scale; biologically inspired or biologically mediated energy services; direct air carbon-capture systems; and electrochemical pathways for emissions reduction and conversion. However, these approaches are unlikely to be fielded without policy actions or reforms that support such systems in competitive global energy markets. Such policy measures do NOT require a carbon price. Rather, they could include individual or combined measures such as emission or performance standards, financial incentives (like tax credits or low-cost access to capital), border adjustable tariffs, creation of CO2 utilities, ands public good surcharges. Innovation in both technical and policy arenas are needed to achieve the goals of the Paris agreement signatories, and these innovations can be simultaneously configured to deliver substantive greenhouse gas mitigation.
Production of reduction gases: partial oxidation of hydrocarbons and coal
Energy Technology Data Exchange (ETDEWEB)
Tippmer, K
1976-04-01
After some general remarks on reduction gas and quality demands, the Texaco process of partial oxidation with scrubbing is dealt with. A comparison of current iron-sponge techniques shows that a heat demand below 3 M kcal/t Fe should be envisaged, which means that heavy fuel oil or coal should be used. The special features of oxygen generation, coal processing, demands made on fuel oil, gasoline, and natural gas, gas generation, soot recovery, hydrogen sulphide-carbon dioxide scrubbing, system Benfield HP process, recycle-carbon dioxide scrubbing, auxiliary steam system, gas preheating, recycle gas cooling and compression, process data and heat balances for natural gas (one-heat system) and heating fuel oil or naphtha (two-heat system) are given.
Carrington, M.E.; Keeley, J.E.
1999-01-01
I Both fire regimes and the conditions under which fires occur vary widely. Abiotic conditions (such as climate) in combination with fire season, frequency and intensity could influence vegetation responses to fire. A variety of adaptations facilitate post-fire recruitment in mediterranean climate ecosystems, but responses of other communities are less well known. We evaluated the importance of climate by comparing sites with mediterranean and subtropical climates. 2 We used paired burned and mature sites in chamise chaparral, mixed chaparral and coastal sage scrub (California), and rosemary scrub, sand pine scrub and sand-hill (Florida), to test whether (i) patterns of pre-fire and post-fire seedling recruitment are more similar between communities within a region than between regions, and (ii) post-fire stimulation of seedling establishment is greater in regions with marked fire-induced contrasts in abiotic site characteristics. 3 Post-fire seedling densities were more similar among sites within climatic regions than between regions. Both seedling densities and proportions of species represented by seedlings after fires were generally higher in California. 4 The only site characteristic showing a pre-fire-post-fire contrast was percentage open canopy, and the effect was greater in California than in Florida. Soil properties were unaffected by fire. 5 Mediterranean climate ecosystems in other regions have nutrient-poor soils similar to our subtropical Florida sites, but show post-fire seedling recruitment patterns more similar to the nutrient-rich sites in California. Climate therefore appears to play a more major role than soil characteristics.
Development of an improved two-cycle process for recovering uranium from wet-process phosphoric acid
International Nuclear Information System (INIS)
Chen, H.M.; Chen, H.J.; Tsai, Y.M.; Lee, T.W.; Ting, G.
1987-01-01
An improved two-cycle separation process for the recovery of uranium from wet-process phosphoric acid by extraction with bis(2-ethylhexyl)phosphoric acid (D2EHPA) plus dibutyl butylphosphonate (DBBP) in kerosene has been developed and demonstrated successfully in bench-scale, continuous mixer-settler tests. The sulfuric acid and water scrubbing steps for the recycled extraction in the second cycle solve the problems of the contamination and dilution of the phosphoric acid by the ammonium ion and water and also avoid the formation of undesirable phosphatic precipitates during the subsequent extraction of uranium by recycled organic extractant
A new chemical system solution for acid gas removal
Energy Technology Data Exchange (ETDEWEB)
Seiler, M.; Rolker, J.; Witthaut, D.; Schulze, S. [Evonik Industries AG, Hanau (Germany); Buchholz, S. [Evonik Industries AG, Marl (Germany)
2012-07-01
An energy-efficient absorbent formulation fors eparating acid gases (e.g. CO{sub 2}, H2S) from gas streams such as natural gas, syngas or flue gas is important for a number of industrial applications. In many cases, a substantial share of their costs is driven by the operational expenditure (OPEX) of the CO{sub 2} separation unit. One possible strategy for reducing OPEX is the improvement of the absorbent performance. Although a number of absorbents for the separation of CO{sub 2} from gas streams exist, there is still a need to develop CO{sub 2} absorbents with an improved absorption performance, less corrosion and foaming, no nitrosamine formation, lower energy requirement and therefore less OPEX. This contribution aims at giving a brief state-of-the-art overview followed by an introduction and performance characterization of a new family of amine-based CO{sub 2} absorbents. High cyclic capacities in the range of 2.9 to 3.2 mol CO{sub 2} kg{sup -1} absorbent and low absorption enthalpies of about -30 kJ mol{sup -1} allow for significant savings in the regeneration energy of the new absorbent system. Calculations with the modified Kremser model indicate a reduction in the specific reboiler heat duty of 45 %. Moreover, the high-performance absorbents developed show much lower corrosion rates than state-of-the-art solutions that are currently employed. (orig.)
Investigating animal health effects of sour gas acid forming emissions
International Nuclear Information System (INIS)
Edwards, W.C.
1992-01-01
The effects of sour gas well blowout emissions on livestock are reviewed. Guidelines for safe drilling operations in hydrogen sulfide environments, general hazards and characteristics of hydrogen sulfide, and guidelines for field investigation into the effects of sour gas and acid emissions on livestock are discussed. A case history involving the Ross No. 2 gas well blowout of July 1985 in Rankin County, Mississippi is presented. The blowout lasted for 72 days, and at peak discharge the 500 ppM radius was ca 3.5 miles. A cattle embryo transplant operation located one half mile from the well was affected by the blowout. Examination by a local veterinarian of the cattle demonstrated eye irritation, epiphora, nasal discharge and coughing. After one and a half months of exposure, most animals showed clinical signs of a severe dry hacking cough, epiphora, dry rales over the thoracic inlet, and a bronchial popping sound over the lateral thorax. All animals had eye irritation. Of 55 animals showing signs of respiratory distress and eye irritations, 15 were still clinically ill in May of 1986. 7 refs., 1 tab
UPS and DFT investigation of the electronic structure of gas-phase trimesic acid
Energy Technology Data Exchange (ETDEWEB)
Reisberg, L., E-mail: rebban@ut.ee [Institute of Physics, University of Tartu, W. Oswaldi 1, EE-50411 Tartu (Estonia); Pärna, R. [Institute of Physics, University of Tartu, W. Oswaldi 1, EE-50411 Tartu (Estonia); MAX IV Laboratory, Lund University, Fotongatan 2, 225 94 Lund (Sweden); Kikas, A.; Kuusik, I.; Kisand, V. [Institute of Physics, University of Tartu, W. Oswaldi 1, EE-50411 Tartu (Estonia); Hirsimäki, M.; Valden, M. [Surface Science Laboratory, Optoelectronics Research Centre, Tampere University of Technology, FIN-33101 Tampere (Finland); Nõmmiste, E. [Institute of Physics, University of Tartu, W. Oswaldi 1, EE-50411 Tartu (Estonia)
2016-11-15
Highlights: • In the current study outer valence band electronic structure of benzene-1,3,5-tricarboxylic acid was interpreted. • Experimental and calculated trimesic acid (TMA) spectrum were compared to ones of benzene and benzoic acid. • It is shown that similarities between MO energies and shapes for benzene and TMA exists. • Addition of carboxyl groups to the benzene ring clearly correlates with increasing binding energy of HOMO. - Abstract: Benzene-1,3,5-tricarboxylic acid (trimesic acid, TMA) molecules in gas-phase have been investigated by using valence band photoemission. The photoelectron spectrum in the binding energy region from 9 to 22 eV is interpreted by using density functional theory calculations. The electronic structure of TMA is compared with benzene and benzoic acid in order to demonstrate changes in molecular orbital energies induced by addition of carboxyl groups to benzene ring.
Directory of Open Access Journals (Sweden)
A.M. Spickett
1995-08-01
Full Text Available Free-living ixodid ticks were collected monthly from August 1988 to July 1993 from the vegetation of landscape zones 17 (Sclerocarya caffra/Acacia nigrescens Savanna and 4 (Thickets of the Sabie and Crocodile Rivers in the south-east and south-west of the Kruger National Park respectively, and parasitic ticks from scrub hares in the latter landscape zone. Total tick collections from the vegetation of both landscape zones were lowest in the year following the drought year of August 1991 to July 1992, while the tick burdens of the scrub hares were lowest during the drought year itself.
Relocation of blood gas laboratory to the emergency department helps decrease lactic acid values.
Brazg, Jared; Huang, Phyllis; Weiner, Corey; Singh, Guneet; Likourezos, Antonios; Salem, Linda; Dickman, Eitan; Marshall, John
2018-03-12
Emergency Physicians often rely on Lactic Acid (LA) values to make important clinical decisions. Accuracy of LA values improve when blood gas analysis is performed in the emergency department (ED) as opposed to a satellite laboratory (SL). To investigate an association between blood gas laboratory location and accuracy of ED lactic acid samples. The study team evaluated lactic acid values from venous and arterial blood gas samples drawn between June 1, 2015 and September 30, 2016. The study was exempt from institutional review board approval. Samples were separated into two groups: those which were drawn prior to and after relocation of the blood gas laboratory to the ED. The data, including patient demographic characteristics, acute illness severity indices, and blood gas results were compared within and between each group using t-test for continuous variables and chi-square test for categorical variables. The primary outcome was the mean lactate value measured in the SL group in 2015 compared to the ED group in 2016. Potassium and creatinine values were measured between the two groups as secondary outcomes. Of the 21,595 consecutive samples drawn, 10,363 samples were from the SL group and 11,232 from the ED group. The SL group included 5458 (52.7%) women; mean (SD) age was 61.8 (21.0). The ED group contained 5860 (52.2%) women; mean (SD) age was 61.7 (20.5). Mean Emergency Severity Index (ESI) were the same in each group at 2.31 and rates of Systemic Inflammatory Response Syndrome (SIRS) were also equivalent in each group at 22.2%. Significant differences were found between LA values in the SL group (mean 2.21mmol/L) and in the ED group (mean 1.99mmol/L) with a p value of values in the SL group (mean 3.98meq/L) compared to the ED Group (mean 3.96meq/L) with a p value of 0.022. No significant difference was found between the creatinine values. These results suggest that mean lactate values decreased when measured in an ED blood gas laboratory and may provide more
Relocation of blood gas laboratory to the emergency department helps decrease lactic acid values.
Brazg, Jared; Huang, Phyllis; Weiner, Corey; Singh, Guneet; Likourezos, Antonios; Salem, Linda; Dickman, Eitan; Marshall, John
2018-03-20
Emergency physicians often rely on Lactic Acid (LA) values to make important clinical decisions. Accuracy of LA values improve when blood gas analysis is performed in the emergency department (ED) as opposed to a satellite laboratory (SL). To investigate an association between blood gas laboratory location and accuracy of ED lactic acid samples. The study team evaluated lactic acid values from venous and arterial blood gas samples drawn between June 1, 2015 and September 30, 2016. The study was exempt from institutional review board approval. Samples were separated into two groups: those which were drawn prior to and after relocation of the blood gas laboratory to the ED. The data, including patient demographic characteristics, acute illness severity indices, and blood gas results were compared within and between each group using t-test for continuous variables and chi-square test for categorical variables. The primary outcome was the mean lactate value measured in the SL group in 2015 compared to the ED group in 2016. Potassium and creatinine values were measured between the two groups as secondary outcomes. Of the 21,595 consecutive samples drawn, 10,363 samples were from the SL group and 11,232 from the ED group. The SL group included 5458 (52.7%) women; mean (SD) age was 61.8 (21.0). The ED group contained 5860 (52.2%) women; mean (SD) age was 61.7 (20.5). Mean Emergency Severity Index (ESI) were the same in each group at 2.31 and rates of Systemic Inflammatory Response Syndrome (SIRS) were also equivalent in each group at 22.2%. Significant differences were found between LA values in the SL group (mean 2.21mmol/L) and in the ED group (mean 1.99mmol/L) with a p value of values in the SL group (mean 3.98meq/L) compared to the ED Group (mean 3.96meq/L) with a p value of 0.022. No significant difference was found between the creatinine values. These results suggest that mean lactate values decreased when measured in an ED blood gas laboratory and may provide more
Cathryn H. Greenberg; Daniel G. Neary; Larry D. Harris
1994-01-01
We tested whether the herpetofuunal response to clearcutting followed by site preparation was similar to high-intensity wildfire foIlowed by salvage logging in sand- pine scrub. Herpetofaunal communities were compared in three replicated 5- to 7-yearpost-disturbance treatments and mature sand-pine forest. The three disturbance treatments were (1) high-intensity...
Government review of the countdown companies' 1991 acid gas emissions audits
Energy Technology Data Exchange (ETDEWEB)
1993-08-01
An acid gas emissions verification program was implemented in Ontario in 1990 as part of a program for regulating emissions that are precursors to acid rain. The verification program applied to four companies, three in the metals industry and one electric utility. These emitters were required to limit annual SO[sub 2] and nitrogen oxides emissions to specified levels in stages according to a set schedule. The four companies were required to prepare and submit sulfur mass balance procedures manuals, determine the overall uncertainty of their respective annual emissions, and engage an independent auditor to develop an audit protocol manual and conduct audits of the reported emissions. For Ontario Hydro, the auditor was also required to evaluate the continuous flue gas monitoring systems at the utility's fossil-fuel power plants. The auditors confirmed that the metallurgical companies' reported emissions were within the required limits. For Ontario Hydro, the audit also confirmed that both SO[sub 2] and nitrogen oxide emissions were within the limits specified for 1991. The auditor also indicated that there were no major discrepancies with the procedures manuals that affected the calculated SO[sub 2] and nitrogen oxides emissions. 6 refs., 2 tabs.
Directory of Open Access Journals (Sweden)
Amrish Saxena
2014-01-01
Full Text Available Scrub typhus is an acute infectious illness, distributed throughout the Asia Pacific rim. In India, it has been reported from northern, eastern, and southern India. However, cases of scrub typhus have not been well-documented from Vidarbha, an eastern region of Maharashtra state in central India. We report two cases of complicated scrub typhus from Vidarbha region. These cases admitted in unconscious state with 8-10 days history of fever, body ache, cough, and progressive breathlessness. The diagnosis in both cases was based on presence of eschar, a positive Weil-Felix test, and a positive rapid diagnostic test (immunochromatographic assay. Both cases were complicated by acute respiratory distress syndrome (ARDS and multiorgan failure. Both of them presented in their 2 nd week of illness and died during the hospital course in spite of intensive supportive care. The main cause of mortality was delayed referral leading to delay in diagnosis and treatment.
Candasamy, Sadanandane; Ayyanar, Elango; Paily, Kummankottil; Karthikeyan, Patricia Anitha; Sundararajan, Agatheswaran; Purushothaman, Jambulingam
2016-12-01
Human cases of scrub typhus are reported every year from Puducherry and adjoining areas in southern India. However, information on the presence of causative agent, Orientia tsutsugamushi, and its vectors is lacking. Hence, the objective of the study was to find out the vector as well as pathogen distribution in rodents and shrews present in the scrub typhus-reported areas in southern India. Trombiculid mites were collected by combing rats and shrews collected using Sherman traps and identified to species level following standard taxonomical keys. The serum samples of the animals were used for Weil-Felix test and the clots containing blood cells were used for DNA extraction and polymerase chain reaction (PCR). A total of 181 animals comprising four rodent species and one shrew species were collected from 12 villages. High proportion of chiggers was collected from the shrew, Suncus murinus (79.1%) and Rattus rattus (47.6%). A total of 10,491 trombiculid mites belonging to nine species were collected. Leptotrombidium deliense, the known vector of scrub typhus pathogen, was the predominant species (71.0%) and the chigger (L. deliense) index was 41.1 per animal. Of the 50 animals screened for the pathogen, 28 showed agglutination against OX-K in Weil-Felix test indicating the presence of antibodies against O. tsutsugamushi, the causative agent of scrub typhus. PCR carried out with the DNA extracted from blood samples of two of the animals were positive for GroEl gene of O. tsutsugamushi. L. deliense index was well above the critical limit of chigger load, indicating that all the villages were receptive for high risk of transmission of scrub typhus to human. Pathogen positivity was higher among animals collected from villages recorded for higher chigger indices due to active transmission between the chigger mites and reservoir host animals. The results are suggestive of routine vector/pathogen surveillance at hot spots to initiate timely preventive measures.
Hot gas cleaning, a targeted project
Energy Technology Data Exchange (ETDEWEB)
Romey, I. [University of Essen, Essen (Germany)
1998-11-01
Advanced hot gas cleaning systems will play a key role in future integrated combined cycle technologies. IGCC demonstration plants in operation or under construction are at present equipped with conventional wet gas scrubbing and cleaning systems. Feasibility studies for those IGCC plants have shown that the total efficiency of the processes can be improved using hot gas cleaning systems. However, this technology has not been developed and tested at a technical scale. Six well-known European industrial companies and research centres jointly worked together since January 1996 on a Targeted Project `Hot Gas Cleaning` to investigate and develop new hot gas cleaning systems for advanced clean coal power generation processes. In addition project work on chemical analysis and modelling was carried out in universities in England and Germany. The latest main findings were presented at the workshop. The main project aims are summarised as follows: to increase efficiency of advanced power generation processes; to obtain a reduction of alkalis and environmental emissions e.g. SO{sub 2}, NO{sub x}, CO{sub 2} and dust; and to develop the design basis for future industrial plants based on long-term operation of laboratory, pilot and demo-plants. To cover a range of possible process routes for future hot gas cleaning systems the following research programme is under investigation: removal of trace elements by different commercial and self developed sorbents; gas separation by membranes; separation of gas turbine relevant pollutants by hot filter dust and; H{sub 2}S removal and gas dedusting at high temperatures. 13 figs.
International Nuclear Information System (INIS)
Channa, N.A.; Khand, F.D.; Noorani, M.A.; Bhanger, M.I.
2002-01-01
Forty-four human gallstone samples either of pure cholesterol or cholesterol and bilirubin were randomly selected and analyzed by capillary gas liquid chromatography for the relative percentage composition of free and total fatty acids. The results showed that bound fatty acids were present in higher amounts than the free fatty acids. Amongst the bound fatty acids the percentage occurrence for palmitic acid was highest followed by stearic, oleic, linoleic and myristic acids. Fatty acids myristic, palmitic and linoleic were present in higher amounts in cholesterol gallstones, whereas stearic acid in cholesterol and bilirubin gallstones. When compared, no significant difference (p < 0.05) in the levels of free and bound fatty acids were seen in gallstones of males and females. The results suggest that bound fatty acids have a role to play in the structure of gallstones. (author)
OAS proteins and cGAS: unifying concepts in sensing and responding to cytosolic nucleic acids.
Hornung, Veit; Hartmann, Rune; Ablasser, Andrea; Hopfner, Karl-Peter
2014-08-01
Recent discoveries in the field of innate immunity have highlighted the existence of a family of nucleic acid-sensing proteins that have similar structural and functional properties. These include the well-known oligoadenylate synthase (OAS) family proteins and the recently identified OAS homologue cyclic GMP-AMP (cGAMP) synthase (cGAS). The OAS proteins and cGAS are template-independent nucleotidyltransferases that, once activated by double-stranded nucleic acids in the cytosol, produce unique classes of 2'-5'-linked second messenger molecules, which - through distinct mechanisms - have crucial antiviral functions. 2'-5'-linked oligoadenylates limit viral propagation through the activation of the enzyme RNase L, which degrades host and viral RNA, and 2'-5'-linked cGAMP activates downstream signalling pathways to induce de novo antiviral gene expression. In this Progress article, we describe the striking functional and structural similarities between OAS proteins and cGAS, and highlight their roles in antiviral immunity.
Characteristics of coastal sage scrub in relation to fire history and use by California gnatcatchers
Jan L. Beyers; Ginger C. Pena
1995-01-01
Abstract: Plant cover and vegetation structure were examined at two inland coastal sage scrub sites differing in fire history and use by California gnatcatchers. Salvia mellifera and Eriogonum fasciculatum dominated one site; shrub cover on gnatcatcher occupied plots averaged 50 percent greater than on unoccupied plots. At the other site, gnatcatcher-occupied plots had...
Directory of Open Access Journals (Sweden)
Esmaeil Jorjani
2016-11-01
Full Text Available In this study, solvent extraction and precipitation stripping were used to produce rare earth elements (REEs. Tributyl phosphate (TBP was used to extract yttrium, lanthanum, cerium, and neodymium from an aqueous solution produced by nitric acid leaching of apatite concentrate. In the extraction stage, the effects of TBP concentration, pH, contact time, temperature, and phase ratio were investigated. The results show that about 95%, 90%, 87% and 80% of neodymium, cerium, lanthanum, and yttrium, respectively, can be extracted in optimum conditions of extraction. Hot, deionized water was used to scrub the impurities from the loaded organic phase. The results showed that three stages of scrubbing with a phase ratio (Va/Vo of five removed about 80%, 30%, 27%, and 15% of Ca, Mg, Fe, and P, respectively, from loaded TBP, while less than 9% of total REEs was lost. The effects on precipitation stripping of oxalic acid concentration, contact time, and phase ratio were investigated. The results showed that precipitation stripping is a viable alternative to traditional acid stripping in the REEs production process. Mixed REEs oxide with an assay of about 90% can be achieved as a final product.
Developments in odour control and waste gas treatment biotechnology: a review.
Burgess, J E; Parsons, S A; Stuetz, R M
2001-02-01
Waste and wastewater treatment processes produce odours, which can cause a nuisance to adjacent populations and contribute significantly to atmospheric pollution. Sulphurous compounds are responsible for acid rain and mist; many organic compounds of industrial origin contribute to airborne public health concerns, as well as environmental problems. Waste gases from industry have traditionally been treated using physicochemical processes, such as scrubbing, adsorption, condensation, and oxidation, however, biological treatment of waste gases has gained support as an effective and economical option in the past few decades. One emergent technique for biological waste gas treatment is the use of existing activated sludge plants as bioscrubbers, thus treating the foul air generated by other process units of the wastewater treatment system on site, with no requirement for additional units or for interruption of wastewater treatment. Limited data are available regarding the performance of activated sludge diffusion of odorous air in spite of numerous positive reports from full-scale applications in North America. This review argues that the information available is insufficient for precise process design and optimization, and simultaneous activated sludge treatment of wastewater and airborne odours could be adopted worldwide.
Tian, Zhixin; Wang, Xue-Bin; Wang, Lai-Sheng; Kass, Steven R
2009-01-28
Deprotonation of tyrosine in the gas phase was found to occur preferentially at the phenolic site, and the conjugate base consists of a 70:30 mixture of phenoxide and carboxylate anions at equilibrium. This result was established by developing a chemical probe for differentiating these two isomers, and the presence of both ions was confirmed by photoelectron spectroscopy. Equilibrium acidity measurements on tyrosine indicated that deltaG(acid)(o) = 332.5 +/- 1.5 kcal mol(-1) and deltaH(acid)(o) = 340.7 +/- 1.5 kcal mol(-1). Photoelectron spectra yielded adiabatic electron detachment energies of 2.70 +/- 0.05 and 3.55 +/- 0.10 eV for the phenoxide and carboxylate anions, respectively. The H/D exchange behavior of deprotonated tyrosine was examined using three different alcohols (CF3CH2OD, C6H5CH2OD, and CH3CH2OD), and incorporation of up to three deuterium atoms was observed. Two pathways are proposed to account for these results, and all of the experimental findings are supplemented with B3LYP/aug-cc-pVDZ and G3B3 calculations. In addition, it was found that electrospray ionization of tyrosine from a 3:1 (v/v) CH3OH/H2O solution using a commercial source produces a deprotonated [M-H]- anion with the gas-phase equilibrium composition rather than the structure of the ion that exists in aqueous media. Electrospray ionization from acetonitrile, however, leads largely to the liquid-phase (carboxylate) structure. A control molecule, p-hydroxybenzoic acid, was found to behave in a similar manner. Thus, the electrospray conditions that are employed for the analysis of a compound can alter the isomeric composition of the resulting anion.
The Flakt-Hydro process: flue gas desulfurization by use of seawater
Energy Technology Data Exchange (ETDEWEB)
Xia, W.Z. [ABB China Limited, Shanghai (China)
1999-07-01
ABB's seawater scrubbing process (the Flakt-Hydro process) for flue gas desulfurization has recently triggered interest among power producers because of its simple operating principle and high reliability. The process uses seawater to absorb and neutralize sulfur dioxide in flue gases. The absorbed gas is oxidized and returned to the ocean in the form it originated in the first place, namely as dissolved sulfate salts. The process uses the seawater downstream of the power plant condensers. This paper gives an introduction to the basic principle of the process and presents some of the recent power plant applications, namely at the Paiton Private Power Project; Phase 1 (2 x 670 MWe) in Indonesia and at the Shenzhen West Power Plant, Unit 2 (300 MWe) in China.
Chang, Ko; Lee, Nan-Yao; Ko, Wen-Chien; Lin, Wei-Ru; Chen, Yen-Hsu; Tsai, Jih-Jin; Chen, Tun-Chieh; Lin, Chun-Yu; Chang, Ya-Ting; Lu, Po-Liang
2017-06-22
The clinical manifestations of scrub typhus, murine typhus and acute Q fever in the elderly are not clear. We conducted a retrospective study to identify the characteristics of the elderly aged ≥65 years with a comparison group aged 18-64 years among patients with scrub typhus, murine typhus, or acute Q fever who were serologically confirmed at three hospitals in Taiwan during 2002-2011. Among 441 cases, including 187 cases of scrub typhus, 166 acute Q fever, and 88 murine typhus, 68 (15.4%) cases were elderly patients. The elderly had a higher severe complication rate (10.3% vs. 3.5%, p = 0.022), but did not have a significantly higher mortality rate (1.47% vs. 0.54%, p = 0.396). Compared with those without severe complications, we found the elderly (p = 0.022), dyspnea (p = 0.006), less relative bradycardia (p = 0.004), less febrile illness (p = 0.004), prolonged prothrombin time (PT) (p = 0.002), higher levels of initial C-reactive protein (p = 0.039), blood leukocyte counts (p = 0.01), and lower platelet counts (p = 0.012) are significantly associated with severe complications. Only prolonged prothrombin time was associated with severe complications in multivariate analysis (p = 0.018, CI 95% 0.01-0.66). Among clinical symptoms and laboratory data, multivariate analysis revealed chills was less frequently occurred in the elderly (p = 0.012, 95% confidence interval [CI]: 1.33-9.99). The elderly cases with scrub typhus, murine typhus, or acute Q fever would be more likely to have severe complications, for which prothrombin time prolongation is an important predictor for severe complications. Copyright © 2017. Published by Elsevier B.V.
Rodkvamtook, Wuttikon; Ruang-areerate, Toon; Gaywee, Jariyanart; Richards, Allen L.; Jeamwattanalert, Pimmada; Bodhidatta, Dharadhida; Sangjun, Noppadon; Prasartvit, Anchana; Jatisatienr, Araya; Jatisatienr, Chaiwat
2011-01-01
Orientia tsutsugamushi, an obligate intracellular Gram-negative bacterium, is the causative agent of scrub typhus, a vector-borne disease transmitted by infected chiggers (trombiculid mite larvae). In 2002, an outbreak of scrub typhus occurred among Royal Thai Army troops during the annual field training at a military base in Bothong district, Chonburi province, central Thailand. This report describes the outbreak investigation including its transmission cycle. Results showed that 33.9% of 17...
Brooijmans, T; Okhuijsen, R; Oerlemans, I; Schoenmakers, P J; Peters, R
2018-05-14
Pyrolysis - gas chromatography - (PyGC) is a common method to analyse the composition of natural and synthetic resins. The analysis of acid functionality in, for example, waterborne polyacrylates and polyurethanes polymers has proven to be difficult due to solubility issues, inter- and intramolecular interaction effects, lack of detectability in chromatographic analysis, and lack of thermal stability. Conventional analytical techniques, such as PyGC, cannot be used for the direct detection and identification of acidic monomers, due to thermal rearrangements that take place during pyrolysis. To circumvent this, the carboxylic acid groups are protected prior to thermal treatment by reaction with 2-bromoacetophenone. Reaction conditions are investigated and optimised wrt. conversion measurements. The aproach is applied to waterborne polyacryalates and the results are discussed. This approach enables identification and (semi)quantitative analysis of different acid functionalities in waterborne polymers by PyGC. Copyright © 2018 Elsevier B.V. All rights reserved.
A method for the purification of natural gas from acidic components
Energy Technology Data Exchange (ETDEWEB)
Grinman, B.Kh.
1981-01-01
In the method of purifying natural gas from acidic components by means of injecting it into a layer of natural absorbers for the purpose of increasing the level of recovering CO/sub 2/, a water bearing terrigenic layer, containing silicates, carbonates, and sulfates of alkaline earth metals and layer water with a pH of 7.0 to 9.0 are used. Example. Specimens of rock from the Shatlyk deposit, saturated with layer water with a general mineralization of 19.8% grams per liter and natural gas from the Northern Dengiskul deposit with a CO/sub 2/ content of 3.2 volumetric percentage were used. The installation with the core specimens was placed in a thermostat, and was blown through with helium until complete air pressure was attained, and afterwards, 14.1 liters of natural gas were supplied. The initial pressure was 40.1 kilogauss per square centimeter, the test temperature was 50/sup 0/, and the duration of the experiment was 20 days. After finishing the test, the amount of CO/sub 2/ left in the gas was determined and the amount of the CO/sub 2/ absorbed by rock was also determined. The amount of CO/sub 2/, which entered the reaction with rock was 60% of the general amount of CO/sub 2/ in natural gas. The amount of CO/sub 2/ absorbed by the rock was 10%.
Production of adsorbent from palm shell for radioactive iodine scrubbing process
International Nuclear Information System (INIS)
Mohamad Azman Che Mat Isa; Ku Halim Ku Hamid; Muhd Noor Muhd Yunus; Mohamad Puad Abu; Abdul Halim Badaruddin; Mohammad Nizammudin Abd Aziz; Muhd Ridwan Abdul Rahim
2010-01-01
The biggest biomass source in Malaysia comes from oil palm industry. According to the statistic of year 2004, Malaysia produced 40 million tones per year of biomass which 30 million tones of biomass originated from the oil palm industries. Therefore, the biomass waste such as palm kernel shell can be used to produce granular adsorbent for radioactive materials. For that reason, a newly system, called Rocking Kiln - Fluidized Bed (RK - FB) was developed to utilize large amount of the biomass to produce high value added product. Charcoal or chemically produced activated carbon could be produced by using the kiln. Washing process was introduced to remove particles, minerals and volatile matters from charcoal produced and then would create more surface area in the adsorbent by creating more active sites. In this research, the adsorbent produced was used to scrub iodine 131. In nuclear power reactor, iodine isotope 131 is produced during nuclear fission, and this elementary radioactive iodine may pollute exhaust air streams that could cause thyroid cancer. For removal of radioactive iodine, normally a potassium iodide - impregnated activated carbon (KI - AC) is used. Thus, a process will be developed to produce KI - AC and this product will be used to calculate the efficiency to remove the radioactive iodine 131.The results obtain show that adsorbent produced has a high potential to be used in radioactive adsorbing and likely more economics. This paper will elaborate further the experimental set-up of in Kiln - Fluidized Bed (RK - FB), adsorbent quality and radioactive scrubbing process. (author)
The Use of natural fatty acids in processing tritium gas
International Nuclear Information System (INIS)
El-Sharnouby, A.K.; Abdelgeleel, M.; Eskander, S.B.
1997-01-01
Natural unsaturated fatty acid (e.g cotton, corn, litmus, castor and palm oils) were used to fix tritium gas. The data obtained show that the affinity of the different used natural oils fixation of hydrogen (tritium) was in the following order: cotton oils> corn oil> litmus oil> castor oil> palm oil. The quantity of hydrogen (tritium) which can be fixed by one gram cotton oil is about 5.824 ml H 2 (5.56 x 10 1 1 Bq tritium) while one gram corn oil can fix only 5.04 ml H 2 (4.811 x 10 1 1 Bq tritium). Tritiated cotton oil and corn oil can be solidified using an epoxy resin (Araldite-B-W-1193), the polymer sample can contain up to 5% by weight from hydrogenated (tritiated) oils. The results obtained show that the compressive strength measurements of the final solid waste forms (fatty acid/epoxy) increased with increasing curing time and decreased with increasing fatty acid content. The leachability of tritium from the final solid waste forms increased with increasing fatty acid content in the polymer matrix. The cumulative leach fraction of tritium varied between 4.00 x 10 -3 cm and 6.60 x 10 -3 cm according to the experimental conditions. 15 figs., 1 tab
International Nuclear Information System (INIS)
Lee, D.A.
1979-02-01
Acids and corrosion products in used perchloroethylene scrubber solutions collected from HTGR fuel preparation processes have been analyzed by several analytical methods to determine the source and possible remedy of the corrosion caused by these solutions. Hydrochloric acid was found to be concentrated on the carbon particles suspended in perchloroethylene. Filtration of carbon from the scrubber solutions removed the acid corrosion source in the process equipment. Corrosion products chemisorbed on the carbon particles were identified. Filtered perchloroethylene from used scrubber solutions contained practically no acid. It is recommended that carbon particles be separated from the scrubber solutions immediately after the scrubbing process to remove the source of acid and that an inhibitor be used to prevent the hydrolysis of perchloroethylene and the formation of acids
Feasibility study of NaOH regeneration in acid gas removal unit using membrane electrolysis
Taufany, Fadlilatul; Pratama, Alvian; Romzuddin, Muhammad
2017-05-01
The world's energy demand is increasing with the development of human civilization. Due to limited energy resource, after 2020 fossil fuels thus is predicted will be replaced by renewable resources. Taking an example, one of the potential renewable energy to be considered is biogas, as its high content of methane, which can be produced via the fermentation process of the organic compounds under controlled anaerobic environment by utilizing the methanogen bacteria. However, prior the further use, this biogas must be purified from its impurities contents, i.e. acid gas of CO2 and H2S, up to 4% and 16 ppmv, respectively, in the acid gas removal unit. This such of purification efforts, will significantly increase the higher heating value of biogas, approximately from 600 to 900 Btu/Scf. During the purification process in this acid gas removal unit, NaOH solution is used as a liquid absorbent to reduce those acid gases content, in which the by-product of alkali salt (brine) was produced as waste. Here we report the feasibility study of the NaOH regeneration process in acid gas removal unit via membrane electrolysis technology, in which both the technical and economic aspects are taken account. To be precise in procedure, the anode semi-cell was filled with the brine solution, while the cathode semi-cell was filled with demineralized water, and those electrodes were separated by the cation exchange membrane. Furthermore, the applied potential was varied ranging from 5, 10, 15 and to 20 V, while the concentration of KCl electrolyte solutions were varied ranging from 0.01, 0.05, 0.1, and to 0.03 M. This study was conducted under controlled temperatures of 30 and 50 °C. Here we found that the % sodium recovery was increased along with the applied potential, temperature, and the decrease in KCl electrolyte concentration. We found that the best results, by means of the highest % sodium recovery, i.e. 97.26 %, was achieved under the experimental condition of temperature at 30
International Nuclear Information System (INIS)
Laser, M.; Barnert-Wiemer, H.; Beaujean, H.; Merz, E.; Vygen, H.
1975-01-01
The AKUT process consists of the following process steps: (1) aerosol retention by an electrostatic separator followed by HEPA filters, (2) oxidation of CO with O 2 or reaction of excess O 2 with CO, respectively, (3) compression, (4) scrubbing and/or liquefaction, (5) separation of krypton by distillation, and (6) separation of tritiated water and iodine by adsorption or chemical reaction. Liquefied off-gas with low permanent gas content resulting from graphite burning with oxygen may be distilled at ambient temperature. Off-gas with higher permanent gas content from burning with oxygen enriched air must be processed at lower temperature. The ambient temperature flow sheet is preferable from an economic as well as safety point of view. (U.S.)
Hwang, Kyungo; Jang, Ha Nee; Lee, Tae Won; Cho, Hyun Seop; Bae, Eunjin; Chang, Se-Ho; Park, Dong Jun
2017-03-15
Renal involvement in scrub typhus ranges from simple urinary abnormalities to acute kidney injury (AKI) leading to death. This study evaluated the incidence, predictors and prognosis of AKI associated with scrub typhus according to the RIFLE (risk, injury, failure, loss, end-stage kidney disease) criteria. We retrospectively evaluated the medical records of patients diagnosed with scrub typhus from January 2001 to November 2013 in Gyeongsang National University Hospital. During the study period, 510 patients were diagnosed with scrub typhus and the incidence of AKI was 35.9%. There were 132 (25.9%) patients at risk, 37 (7.3%) with injury and 14 (2.7%) with failure. In comparison with the non-AKI group, the AKI group was older (73.9 vs 63.4 years, pscrub typhus. Our current results suggest that the presence of underlying CKD, older age, lower serum albumin level and time to hospital presentation after symptom onset were important risk factors to determine occurrence of AKI. Whether earlier diagnosis and treatment in patients with the above risk factors reduce the incidence and severity of AKI deserves to be investigated. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
BUSCA-JUN91. Reference manual for the calculation of radionuclide scrubbing in water pools
International Nuclear Information System (INIS)
Ramsdale, S.A.; Friederichs, H.G.
1995-06-01
BUSCA models the decontamination of a bubble as it rises through a water pool. The bubble may contain a mixture of non-condensable gases, steam, iodine vapor and aerosol particles. The bubble thermal-hydraulics are modelled as well as the removal of soluble vapour and aerosol contaminants. The code was originally developed at SRD (part of the UK Atomic Energy Authority) during the mid 1980's. A description of an early version of the code was presented in Reference. Since then, the code has been further enhanced by collaboration within the European Pool Scrubbing Group and additional mechanisms included in its calculations. In particular, PSI (Paul Scherrer Institute, Wuerenlingen) has converted the original FACSIMILE code into FORTRAN and added different bubble initial volume, geometry and bubble rise speed options, UPM (Universidad Politecnica de Madrid) has added the bubble breakup modelling and SRD has added the cluster and plume features. This report describes the BUSCA code version JUN91 which treats the bubble hydrodynamics and removal of aerosol particles and soluble gas in an attempt to calculate the decontamination factor (mass in/mass out), including its input and output requirements. It must be stressed that the development of BUSCA is an on-going project. Currently SRD and PSI have added additional models in their own versions. (orig.)
Energy Technology Data Exchange (ETDEWEB)
S. C. Ashworth
2000-02-27
Technologies were investigated to determine viable processes for removing mercury from the calciner (NWCF) offgas system at the Idaho National Engineering and Environmental Laboratory. Technologies for gas phase and aqueous phase treatment were evaluated. The technologies determined are intended to meet EPA Maximum Achievable Control Technology (MACT) requirements under the Clean Air Act and Resource Conservation and Recovery Act (RCRA). Currently, mercury accumulation in the calciner off-gas scrubbing system is transferred to the tank farm. These transfers lead to accumulation in the liquid heels of the tanks. The principal objective for aqueous phase mercury removal is heel mercury reduction. The system presents a challenge to traditional methods because of the presence of nitrogen oxides in the gas phase and high nitric acid in the aqueous scrubbing solution. Many old and new technologies were evaluated including sorbents and absorption in the gas phase and ion exchange, membranes/sorption, galvanic methods, and UV reduction in the aqueous phase. Process modifications and feed pre-treatment were also evaluated. Various properties of mercury and its compounds were summarized and speciation was predicted based on thermodynamics. Three systems (process modification, NOxidizer combustor, and electrochemical aqueous phase treatment) and additional technology testing were recommended.
Energy Technology Data Exchange (ETDEWEB)
Ashworth, Samuel Clay; Wood, R. A.; Taylor, D. D.; Sieme, D. D.
2000-03-01
Technologies were investigated to determine viable processes for removing mercury from the calciner (NWCF) offgas system at the Idaho National Engineering and Environmental Laboratory. Technologies for gas phase and aqueous phase treatment were evaluated. The technologies determined are intended to meet EPA Maximum Achievable Control Technology (MACT) requirements under the Clean Air Act and Resource Conservation and Recovery Act (RCRA). Currently, mercury accumulation in the calciner off-gas scrubbing system is transferred to the tank farm. These transfers lead to accumulation in the liquid heels of the tanks. The principal objective for aqueous phase mercury removal is heel mercury reduction. The system presents a challenge to traditional methods because of the presence of nitrogen oxides in the gas phase and high nitric acid in the aqueous scrubbing solution. Many old and new technologies were evaluated including sorbents and absorption in the gas phase and ion exchange, membranes/sorption, galvanic methods, and UV reduction in the aqueous phase. Process modifications and feed pre-treatment were also evaluated. Various properties of mercury and its compounds were summarized and speciation was predicted based on thermodynamics. Three systems (process modification, NOxidizer combustor, and electrochemical aqueous phase treatment) and additional technology testing were recommended.
International Nuclear Information System (INIS)
Ashworth, S.C.
2000-01-01
Technologies were investigated to determine viable processes for removing mercury from the calciner (NWCF) offgas system at the Idaho National Engineering and Environmental Laboratory. Technologies for gas phase and aqueous phase treatment were evaluated. The technologies determined are intended to meet EPA Maximum Achievable Control Technology (MACT) requirements under the Clean Air Act and Resource Conservation and Recovery Act (RCRA). Currently, mercury accumulation in the calciner off-gas scrubbing system is transferred to the tank farm. These transfers lead to accumulation in the liquid heels of the tanks. The principal objective for aqueous phase mercury removal is heel mercury reduction. The system presents a challenge to traditional methods because of the presence of nitrogen oxides in the gas phase and high nitric acid in the aqueous scrubbing solution. Many old and new technologies were evaluated including sorbents and absorption in the gas phase and ion exchange, membranes/sorption, galvanic methods, and UV reduction in the aqueous phase. Process modifications and feed pre-treatment were also evaluated. Various properties of mercury and its compounds were summarized and speciation was predicted based on thermodynamics. Three systems (process modification, NOxidizer combustor, and electrochemical aqueous phase treatment) and additional technology testing were recommended
Nuclear ventilation installations. Method of control of the scrubbing coefficient of iodine trap
International Nuclear Information System (INIS)
1982-12-01
The present standard aims at defining a method to control the scrubbing coefficient of radioactive iodine trapping systems, used in nuclear ventilation installations. It applies to the installations where the trapping, efficiency of radioactive iodine has to be known, tested and compared to a reference value generally included in the safety reports. It applies to the installations where the absolute pressure of the air in the ventilation systems is above 1,4. 10 5 Pa (1,4 Bar) [fr
Process for the removal of sulfur oxides and nitrogen oxides from flue gas
International Nuclear Information System (INIS)
Elshout, R.V.
1992-01-01
This patent describes a continuous process for removing sulfur oxide and nitrogen oxide contaminants from the flue gas generated by industrial power plants and boiler systems burning sulfur containing fossil fuels and for converting these contaminants, respectively, into recovered elemental liquid sulfur and nitrogen ammonia and mixtures thereof. It comprises removing at least a portion of the flue gas generated by a power plant or boiler system upstream of the stack thereof; passing the cooled and scrubbed flue gas through an adsorption system; combining a first portion of the reducing gas stream leaving the adsorbers of the adsorption system during regeneration thereof and containing sulfur oxide and nitrogen oxide contaminants with a hydrogen sulfide rich gas stream at a temperature of about 400 degrees F to about 600 degrees F and passing the combined gas streams through a Claus reactor-condenser system over a catalyst in the reactor section thereof which is suitable for promoting the equilibrium reaction between the hydrogen sulfide and the sulfur dioxide of the combined streams to form elemental sulfur
Barker, R.E.; Scott, C.D.; Ryon, A.D.
1980-10-27
Gas produced from coal and containing CH/sub 4/, CO, CO/sub 2/, H/sub 2/ and H/sub 2/S is contacted with CO/sub 2/ scrub liquid to form (1) a liquid CO/sub 2/ stream containing as solutes CH/sub 4/, H/sub 2/S and minor portions of the CO and H/sub 2/, and (2) a gas stream containing CO/sub 2/ and major portions of the CO and H/sub 2/, the CO and H/sub 2/ in this stream being recycled to the means which produces gas from coal, and CO/sub 2/ in the stream being recycled to the scrub liquid. The solute-bearing liquid CO/sub 2/ stream is fractionated into (1) a liquid CO/sub 2/ stream containing CH/sub 4/ and H/sub 2/S, and (2) a H/sub 2//CO gas stream which is recycled into contact with the scrub liquid. The last-mentioned liquid CO/sub 2/ stream is fractionated into (1) a CH/sub 4//CO/sub 2/ gas stream the CO/sub 2/ of which is recycled to the scrub liquid, and (2) a liquid CO/sub 2/ stream containing H/sub 2/S, and CO/sub 2/ of this stream is also recycled to the scrub liquid.
Evaluation of Aroma in Oriental Tobaccos as Based On Valeric Acid Gas Chromatography
Directory of Open Access Journals (Sweden)
Dagnon S
2014-12-01
Full Text Available Levels of valeric acids (isovaleric and 3-methylvaleric in leaves and smoke of different tobacco types were quantified by capillary gas chromatography (GC using flame ionization detector (FID. The aroma characteristics of the smoke were scored by sensory evaluation. It was found that leaves of Oriental and burley tobaccos contain higher amounts of both valeric acid derivatives than Virginia tobaccos containing isovaleric acid but no 3-methylvaleric acid. Strong correlation between the aroma and pleasantness scores of smoke and the content of valeric acids in the leaves of Oriental tobaccos was observed, while it was not the case for leaves of Virginia and burley tobaccos. In all tobacco types no correlation between smoking characteristics and the content of valeric acids in the smoke was established. Regression models involving leaf isovaleric acid were developed that can be used to evaluate aroma and pleasantness of smoke in Oriental tobaccos. The data obtained allow the following conclusions to be drawn: a 3-methylvaleric acid may be a chemical marker to distinguish Virginia tobaccos from Oriental and burley tobaccos; b isovaleric acid content in leaves of Oriental tobaccos may be used for objective aroma evaluation that can be exploited for breeding and market purposes.
A rapid and simple procedure for monitoring valproic acid by gas chromatography
Directory of Open Access Journals (Sweden)
Mohamed Said Mostafa
2018-02-01
Full Text Available Valproic acid (VPA, a widely used antiepileptic drug, has a narrow therapeutic range of 50-100 μg/mL and shows large individual variability. It is very important to monitor the trough VPA concentration using a reliable method. The aim of this study was to develop and validate a rapid gas chromatographic (GC technique for VPA quantification in human plasma and to compare it with the traditional immunoassay method. VPA extraction from human serum was efficient by dichloromethane and hydrochloric acid using octanoic acid as an internal standard. GC analysis was performed using a gas-chromatograph equipped with a flame ionization detector (GC/FID. VPA detection and quantification were accomplished isothermally at 135°C on a Gs-BP 100% dimethylpolysiloxane capillary column (10 m×0.53 mm ID, 2.65 μm film thickness, Supelco, Bellefonte, PA. Injection port and detector temperature were 280°C. Retention times of VPA and internal standard were 1.83 min and 2.33 min, respectively. The calibration curve was linear over the concentration range of 5-320 μg/mL, with a lower limit of detection of 1.25 μg/mL. The internal and inter-day precision was less than 5.3% and 6.1%, respectively, and the accuracy was below 2.8%. VPA recovery was 94.6%. A quick and accurate method for VPA determination in human plasma was developed and validated. It resulted sufficiently selective and sensitive.
Behavior of mercury in the formic acid vent condenser. Interim report
International Nuclear Information System (INIS)
Zamecnik, J.R.
1994-01-01
(This report relates to the Defense Waste Processing Facility.) The concentrations of mercury at the FAFC inlet and exit were measured during the BL1 and PX6 runs of the Integrated DWPF Melter System (IDMS) with the HEME bypassed and without the ammonia scrubber. The results show that mercury concentrations of approximately 2.6-12.7 (mean = 6.2) times saturation occur at the FAFC exit. The concentration of mercury at the SRAT condenser exit was found to be 10 times the saturation value. FAVC exit mercury concentrations of 6.2 times saturation would result in DWPF emitting up to 438 lb/yr of mercury at 100 percent attainments, which is in excess of the permit limit of 175 lb/yr. However, operation of the FAVC with the HEME should reduce the mercury emissions. The addition of the ammonia scrubbers should also reduce the mercury emissions since the nitric acid used to scrub ammonia should also scrub mercury
Schmalzer, Paul A.; Hinkle, G. Ross
1991-01-01
Ten permanent 15 m transects previously established in two oak/saw palmetto scrub stands burned in December 1986, while two transects remained unburned. Vegetation in the greater than 0.5 m and the less than 0.5 m layers on these transects was sampled at 6, 12, 18, 24, and 36 months postburn and determined structural features of the vegetation (height, percent bare ground, total cover). The vegetation data were analyzed from each sampling by height layer using detrended correspondence analysis ordination. Vegetation data for the greater than 0.5 m layer for the entire time sequence were combined and analyzed using detrended correspondence analysis ordination. Soils were sampled at 6, 12, 18, and 24 months postburn and analyzed for pH, conductivity, organic matter, exchangeable cations (Ca, Mg, K, Na), NO3-N, NH4-N, Al, available metals (Cu, Fe, Mn, Zn), and PO4-P. Shrub species recovered at different rates postfire with saw palmetto reestablishing cover greater than 0.5 m within one year, but the scrub oaks had not returned to preburn cover greater than 0.5 m in 3 years after the fire. These differences in growth rates resulted in dominance shifts after the fire with saw palmetto increasing relative to the scrub oaks. Overall changes in species richness were minor, although changes occurred in species richness by height layers due to different growth rates. Soils of well drained and poorly drained sites differed markedly. Soil responses to the fire appeared minor. Soil pH increased at 6 and 12 months postfire; calcium increased at 6 months postburn. Nitrate-nitrogen increased at 12 months postburn. Low values of conductivity, PO4-P, Mg, K, Na, and Fe at 12 months postburn may be related to heavy rainfall the preceding month. Seasonal variability in some soil parameters appeared to occur.
Arazawa, D T; Kimmel, J D; Finn, M C; Federspiel, W J
2015-10-01
The use of extracorporeal carbon dioxide removal (ECCO2R) is well established as a therapy for patients suffering from acute respiratory failure. Development of next generation low blood flow (carbonic anhydrase (CA) immobilized bioactive hollow fiber membrane (HFM) which significantly accelerates CO2 removal from blood in model gas exchange devices by converting bicarbonate to CO2 directly at the HFM surface. This present study tested the hypothesis that dilute sulfur dioxide (SO2) in oxygen sweep gas could further increase CO2 removal by creating an acidic microenvironment within the diffusional boundary layer adjacent to the HFM surface, facilitating dehydration of bicarbonate to CO2. CA was covalently immobilized onto poly (methyl pentene) (PMP) HFMs through glutaraldehyde activated chitosan spacers, potted in model gas exchange devices (0.0151 m(2)) and tested for CO2 removal rate with oxygen (O2) sweep gas and a 2.2% SO2 in oxygen sweep gas mixture. Using pure O2 sweep gas, CA-PMP increased CO2 removal by 31% (258 mL/min/m(2)) compared to PMP (197 mL/min/m(2)) (Premoval by 17% (230 mL/min/m(2)) compared to pure oxygen sweep gas control (Premoval increased by 109% (411 mL/min/m(2)) (Premoval, and when used in combination with bioactive CA-HFMs has a synergistic effect to more than double CO2 removal while maintaining physiologic pH. Through these technologies the next generation of intravascular and paracorporeal respiratory assist devices can remove more CO2 with smaller blood contacting surface areas. A clinical need exists for more efficient respiratory assist devices which utilize low blood flow rates (removal efficiency by shifting equilibrium from bicarbonate to gaseous CO2, through either a bioactive carbonic anhydrase enzyme coating or bulk blood acidification with lactic acid. In this study we demonstrate a novel approach to local blood acidification using an acidified sweep gas in combination with a bioactive coating to more than double CO2 removal
Effects of high fire frequency in creosote bush scrub vegetation of the Mojave Desert
Brooks, M.L.
2012-01-01
Plant invasions can increase fire frequency in desert ecosystems where fires were historically infrequent. Although there are many resource management concerns associated with high frequency fire in deserts, fundamental effects on plant community characteristics remain largely unstudied. Here I describe the effects of fire frequency on creosote bush scrub vegetation in the Mojave Desert, USA. Biomass of the invasive annual grass Bromus rubens L. increased following fire, but did not increase further with additional fires. In contrast, density, cover and species richness of native perennial plants each decreased following fire and continued to decrease with subsequent fires, although not as dramatically as after the initial fire. Responses were similar 5 and 14 years post-fire, except that cover of Hymenoclea salsola Torr. & A. Gray and Achnatherum speciosa Trin. & Rupr. both increased in areas burnt once. These results suggest that control of B. rubens may be equally warranted after one, two or three fires, but revegetation of native perennial plants is most warranted following multiple fires. These results are valid within the scope of this study, which is defined as relatively short term vegetation responses (???14 years) to short fire return intervals (6.3 and 7.3 years for the two and three fire frequency levels) within creosote bush scrub of the Mojave Desert. ?? 2012 IAWF.
Gas pollutants removal in a single- and two-stage ejector-venturi scrubber.
Gamisans, Xavier; Sarrà, Montserrrat; Lafuente, F Javier
2002-03-29
The absorption of SO(2) and NH(3) from the flue gas into NaOH and H(2)SO(4) solutions, respectively has been studied using an industrial scale ejector-venturi scrubber. A statistical methodology is presented to characterise the performance of the scrubber by varying several factors such as gas pollutant concentration, air flowrate and absorbing solution flowrate. Some types of venturi tube constructions were assessed, including the use of a two-stage venturi tube. The results showed a strong influence of the liquid scrubbing flowrate on pollutant removal efficiency. The initial pollutant concentration and the gas flowrate had a slight influence. The use of a two-stage venturi tube considerably improved the absorption efficiency, although it increased energy consumption. The results of this study will be applicable to the optimal design of venturi-based absorbers for gaseous pollution control or chemical reactors.
Fabrication of remote steam atomized scrubbers for DWPF off-gas system
International Nuclear Information System (INIS)
Nielsen, M.G.; Lafferty, J.D.
1988-01-01
The defense waste processing facility (DWPF) is being constructed for the purpose of processing high-level waste from sludge to a vitrified borosilicate glass. In the operation of continuous slurry-fed melters, off-gas aerosols are created by entrainment of feed slurries and the vaporization of volatile species from the molten glass mixture. It is necessary to decontaminate these aerosols in order to minimize discharge of airborne radionuclide particulates. A steam atomized scrubber (SAS) has been developed for DWPF which utilizes a patented hydro- sonic system gas scrubbing method. The Hydro-Sonic System utilizes a steam aspirating-type venturi scrubber that requires very precise fabrication tolerances in order to obtain acceptable decontamination factors. In addition to the process-related tolerances, precision mounting and nozzle tolerances are required for remote service at DWPF
Advanced Flue Gas Desulfurization (AFGD) Demonstration Project, A DOE Assessment; FINAL
International Nuclear Information System (INIS)
National Energy Technology Laboratory
2001-01-01
The AFGD process as demonstrated by Pure Air at the Bailly Station offers a reliable and cost-effective means of achieving a high degree of SO(sub 2) emissions reduction when burning high-sulfur coals. Many innovative features have been successfully incorporated in this process, and it is ready for widespread commercial use. The system uses a single-loop cocurrent scrubbing process with in-situ oxidation to produce wallboard-grade gypsum instead of wet sludge. A novel wastewater evaporation system minimizes effluents. The advanced scrubbing process uses a common absorber to serve multiple boilers, thereby saving on capital through economies of scale. Major results of the project are: (1) SO(sub 2) removal of over 94 percent was achieved over the three-year demonstration period, with a system availability exceeding 99.5 percent; (2) a large, single absorber handled the combined flue gas of boilers generating 528 MWe of power, and no spares were required; (3) direct injection of pulverized limestone into the absorber was successful; (4) Wastewater evaporation eliminated the need for liquid waste disposal; and (5) the gypsum by-product was used directly for wallboard manufacture, eliminating the need to dispose of waste sludge
Extractive distillation of nitric acid using the two-pot concept
International Nuclear Information System (INIS)
Counce, R.M.; Groenier, W.S.; Holland, W.D.; Jubin, R.T.; North, E.D.; Thompson, L.E. Jr.; Hebble, T.L.
1982-12-01
Experiments have confirmed the validity of a novel design for a nitric acid concentration system for use in shielded nuclear fuel reprocessing plants. Current plans for producing the scrub solution for the IODOX process require the concentration and recycle of low strength ( 3 ) 2 as the solvent and features two pots: an extractive distillation pot in which a concentrated acid product is obtained by contacting the acid feed with the solvent and a solvent recovery pot in which the solvent is dehydrated and recovered for recycle. In these experiments, a concentrated product of 89 wt % nitric acid was produced from azeotropic feed. The available vapor-liquid equilibria data for the Mg(NO 3 ) 2 -HNO 3 -H 2 O system has been empirically correlated, and a design methodology has been developed for the two-pot extractive distillation process
International Nuclear Information System (INIS)
Eskell, C.J.; Pick, M.E.
1980-04-01
A procedure for simultaneous determination of ethylenediaminetetraacetic acid (EDTA), nitrilotriacetic acid (NTA), citric acid and oxalic acid by gas liquid chromatography is described. The involatile acids are first concerted to their volatile methyl ester derivatives by reaction with boron trifluoride in methanol. Transition metal ions (Fe 3+ , Cr 3+ and Ni 2+ ) which will be present in decontamination liquors from nuclear reactors, and form strong chelates with the acids, have been shown to cause no interference to the esterification reaction. The esters were separated by temperature programming on a 3.5 metre capillary column packed with 3% OV1 on Diatomite CQ and were detected by flame ionisation. (author)
The selective generation of acetic acid directly from synthesis gas
International Nuclear Information System (INIS)
Knifton, J.F.
1986-01-01
The authors conclude that each of the ruthenium, cobalt and iodide-containing catalyst components have very specific roles to play in the ''melt'' catalyzed conversion of synthesis gas to acetic acid. C 1 -Oxygenate formation is only observed in the presence of ruthenium carbonyls - [Ru(CO) 3 I 3 ] - is here the dominant species - and there is a direct relationship between liquid yield, ΣOAc - productivity and [Ru(CO) 3 I 3 ] - content. Controlled quantities of iodide ensure that initially formed MeOH is rapidly converted to the more reactive methyl iodide. Subsequent cobalt-catalyzed carbonylation to acetic acid may be preparatively attractive (>80% selectivity, good yields) relative to competing syntheses, where the [Co(CO) 4 ] - concentration is maximized that is, where the Co/Ru ratio is >1, the syngas feedstock is rich in CO, and the initial iodide/cobalt ratios are ca. unity. Formation of cobalt-iodide species appears to be a competing, inhibitory step in this catalysis
Chierakul, Wirongrong; de Fost, Maaike; Suputtamongkol, Yupin; Limpaiboon, Roongreung; Dondorp, Arjen; White, Nicholas J.; van der Poll, Tom
2004-01-01
Interferon (IFN)-gamma plays an important role in the induction of a type 1 immune response against intracellular pathogens. We compared the plasma levels of IFN-gamma and IFN-gamma-inducing cytokines in adult Thai patients with scrub typhus, caused by the obligate intracellular bacterium Orientia
Criteria for selecting a flue gas purification system for waste incineration plants
Energy Technology Data Exchange (ETDEWEB)
Mosch, H
1985-12-01
This paper evaluates the available systems with a view to three basic principles of gaseous effluent removal, relating to dust, SO/sub 2/, HCl and HF, by discussing criteria such as performance with regard to environmental hygiene, performance with regard to material or energy consumption, terms and conditions, operational conditions, and economics. The three methods discussed are: (1) Scrubbing and effluent treatment including evaporation and flue gas reheating or other means of treating the flue gas cooled down to about 65/sup 0/C. (2) Spray sorption by means of flash drying reactors, similar to the spray drying method. (3) Blow-in sorption, as the method may be called. The dry, powdered reagent, in general slack lime with at least 90 p.c. of Ca(OH)/sub 2/, is blown into the reactors. (orig./HP).
[Investigation of reference intervals of blood gas and acid-base analysis assays in China].
Zhang, Lu; Wang, Wei; Wang, Zhiguo
2015-10-01
To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument
DEFF Research Database (Denmark)
Bysted, Anette; Cold, S; Hølmer, Gunhild Kofoed
1999-01-01
Considering the need for a quick direct method for measurement of the fatty acid composition including trans isomers ofhuman adipose tissue we have developed a procedure using gas-liquid chromatography (GLC) alone, which is thussuitable for validation of fatty acid status in epidemiological studies...... for 25 min, and finally raised at 25 degrees C/min to 225 degrees C. The trans and cis isomers of18:1 were well separated from each other, as shown by silver-ion thin-layer chromatography. Verification by standardsshowed that the trans 18:1 isomers with a double bond in position 12 or lower were...
An emissions audit from a chain-grate stoker burning d-RDF
International Nuclear Information System (INIS)
Jackson, P.M.; King, P.G.
1993-01-01
This report describes the Emissions Audit carried out on a chain-grate stoker shell boiler burning dRDF at the Senior Foster Wheeler test facility in Wakefield to provide design data for gas cleaning equipment. Sampling was therefore performed in the absence of any abatement equipment other than a standard cyclonic grit arrestor. The chain-grate stoker boiler was tested at two steam loads: 40% MCR to represent low load and, 80% MCR to represent high steam load. Acid gas concentrations in the flue gas were unacceptable. The dominant gas being HCl at 850-1000mgm -3 for both tests, was considerably higher than the guideline for new plant of 50mgm -3 . HF was also measured at concentrations in excess of the guidance value. It will be necessary to install acid gas scrubbing equipment before dRDF will be acceptable as a fuel. SO 2 and NO x were both present in measurable concentrations but under current guidance were no cause for concern. (author)
Lü, Zhenbo; Tian, Songbai; Zhai, Yuchun; Sun, Yanwei; Zhuang, Lihong
2004-05-01
The petroleum carboxylic acids in 200-420 degrees C distillate of crude oil were separated by the extraction with column chromatography on an anion exchange resin. The effect of the composition and structure of naphthenic acids on separation were studied by the infra-red (IR) spectroscopic techniques. Naphthenic acids and iso-butane reagent gas were introduced into the ion source for chemical ionization, in which the ions represented by [M + C4H9]+ were used to calculate the relative molecular mass for each acid. Based on the mass spectra of pure fatty and naphthenic acids, in combination with the z-series formula CnH(2n + z)O2, the naphthenic acids can be classified into fatty, mono-, bi- ... hexa-cyclic types. The results indicated that the relative molecular mass range of naphthenic acids in this distillates was 170-510, and the carbon number range was C10-C35. The contents of bi-cyclic and tri-cyclic naphthenic acids were higher than others.
International Nuclear Information System (INIS)
Osuteye, I.
2015-01-01
Crude oil is the life-blood of the global economy. Its importance stems from the fact that it is a base product for a wide variety of goods [Drugs, Plastics, Liquefied Petroleum Gas (LPG)]. The oil discovery (over 3 billion barrel reserves in hydrocarbon and gas), about 60 km offshore between the Deepwater Tano and Cape Three Points Block in South western Ghana is a valuable natural asset and it has the potential of boosting the Ghanaian economy. During petroleum processing, various waste products are generated. One of such products is Naphthenic acids (NA). Naphthenic acids are organic acids naturally occurring in crude oil and a constituent of waste associated with oil refinery. Naphthenic acids serve as biomarkers for identification of the source of crude oil. The presence of Naphthenic acid in the aquatic environment causes toxic effects due to their weak biodegradable nature; the toxicity of Naphthenic acids depends on the class of Naphthenic acids present in the crude oil. The study assessed the profile of Naphthenic acids in Ghana’s Jubilee crude oil using Low Resolution Electron Impact – Gas Chromatography Mass Spectrometry (LREI-GCMS) after isolation of Naphthenic acids in the Jubilee oil by a modified Kupchan’s Partitioning Process. The Mass Spectrometric (MS) Work Station Software was used for the identification of the Naphthenic acids present in the Jubilee crude oil. The quality of the Jubilee oil was also evaluated through the use of some key physico-chemical parameters [Total Acid Number (TAN), Sulphur Content, Viscosity, Pour Point, Flashpoint, Water Content and Densities] based on the American Standards for Testing and Materials (ASTM, 2007). The Total Acid Number was determined by Colorimetric Titration (ASTM D974); Sulphur Content by X-ray Fluorescent Spectrometry (ASTM D4294); Pour Point by the use of the SETA cloud and Pour Point Refrigerator Technique (ASTM D97); Viscosity by Gravity Timed Method (ASTM D445); Density by the Hydrometer
International Nuclear Information System (INIS)
Zmuda, J.T.; Smith, P.V.
1991-01-01
Dry sorbent injection (DSI) has been successfully demonstrated on coal fired boiler applications as a means of reducing sulfur dioxide emissions. More recently, the dry sorbent injection process was applied to an existing municipal waste incinerator to provide acid gas emission controls. The results obtained from the successful demonstration of the sorbent injection system on an existing municipal incinerator are presented. Removal efficiencies of compounds such as HCl, SO 2 , SO 3 , mercury, and others by the use of sorbent injection are shown. Effects of the DSI system on downstream equipment, such as electrostatic precipitators, fabric filters, ash handling systems, and waste management is included. The impacts of the DSI system on the furnace is also discussed. In this paper a discussion of dry sorbent injection as a means of reducing acid gas and other emissions from existing municipal waste incinerators which may be affected by the regulations is presented. An application case study will outline typical exhaust conditions, expected pollution reductions, capital and operating costs, and type of available sorbents and their costs
Determination of Fluorine in Fluoro-Organic Compounds in Low Concentrations in Air
1944-06-27
Analysis of 2-Fluoroethanol in Air ..... SUMMARY BIBLIOGRAPHY 15 APPENDIX , 16 FIGURE 1 Apparatus PLATE 1 CDS Scrubber SECRET ) SECRET...liter, and 68$ at 1 - 2 mg. per liter. By using two scrubbers in series, 90$ of di-isopropyl fluorophosphate was recovered at a concentration of 1 to 2...chromic acid and detection of HP by etching of the glass container ; (5) scrub- bing the gas with ammonia and decomposing the fluoro-organic compound4
Characterization of condensed phase nitric acid particles formed in the gas phase
Institute of Scientific and Technical Information of China (English)
Long Jia; Yongfu Xu
2011-01-01
The formation of nitric acid hydrates has been observed in a chamber during the dark reaction of NO2 with O3 in the presence of air.The size of condensed phase nitric acid was measured to be 40-100 nm and 20-65 nm at relative humidity (RH) ≤ 5% and RH = 67% under our experimental conditions, respectively.The nitric acid particles were collected on the glass fiber membrane and their chemical compositions were analyzed by infrared spectrum.The main components of nitric acid hydrates in particles are HNO3·3H2O and NO3-·xH2O (x≥ 4) at low RH, whereas at high RH HNO3·H2O, HNO3·2H2O, HNO3·3H2O and NO3-·xH2O (x≥ 4) all exist in the condensed phase.At high RH HNO3·xH2O (x ≤ 3) collected on the glass fiber membrane is greatly increased, while NO3-·xH2O (x ≥4) decreased, compared with low RH.To the best of our knowledge, this is the first time to report that condensed phase nitric acid can be generated in the gas phase at room temperature.
Sacral Herpes Zoster Associated with Voiding Dysfunction in a Young Patient with Scrub Typhus
Hur, Jian
2015-01-01
When a patient presents with acute voiding dysfunction without a typical skin rash, it may be difficult to make a diagnosis of herpes zoster. Here, we present a case of scrub typhus in a 25-year-old man with the complication of urinary dysfunction. The patient complained of loss of urinary voiding sensation and constipation. After eight days, he had typical herpes zoster eruptions on the sacral dermatomes and hypalgesia of the S1-S5 dermatomes. No cases of dual infection with varicella zoster...
Fast derivatization of fatty acids in different meat samples for gas chromatography analysis.
Figueiredo, Ingrid Lima; Claus, Thiago; Oliveira Santos Júnior, Oscar; Almeida, Vitor Cinque; Magon, Thiago; Visentainer, Jesuí Vergilio
2016-07-22
In order to analyze the composition of fatty acids employing gas chromatography as the separation method, a derivatization of lipids using esterification and transesterification reactions is needed. The methodologies currently available are time consuming and use large amounts of sample and reagents. Thus, this work proposes a new procedure to carry out the derivatization of fatty acids without the need for prior extraction of lipids. The use of small amounts of sample (100mg) allows the analysis to be performed in specific parts of animals, in most cases without having them slaughtered. Another benefit is the use of small amounts of reagents (only 2mL of NaOH/Methanol and H2SO4/Methanol). The use of an experimental design procedure (Design Expert software) allows the optimization of the alkaline and acid reaction times. The procedure was validated for five minutes in both steps. The method was validated for bovine fat, beef, chicken, pork, fish and shrimp meats. The results for the merit figures of accuracy (from 101.07% to 109.18%), precision (RSDintra-day (from 0.65 to 3.93%), RSDinter-day (from 1.57 to 5.22%)), linearity (R(2)=0.9864) and robustness confirmed that the new method is satisfactory within the linear range of 2-30% of lipids in the sample. Besides the benefits of minimizing the amount of samples and reagents, the procedure enables gas chromatography sample preparation in a very short time compared with traditional procedures. Copyright © 2016 Elsevier B.V. All rights reserved.
International Nuclear Information System (INIS)
Eisenberg, G.H. Jr.; Osterman, J.V.
1979-01-01
Scrub typhus immunogens were prepared from Rickettsia tsutsugamushi strains Karp, Kato, Gilliam, Kostival, and Buie by exposing frozen infected yolk sac suspensions to 300 krad of gamma radiation. Mouse protection tests showed that each of the irradiated immunogens protected C3H/HeDub mice against high challenge levels of Karp and Gilliam, but that none of these single-strain immunogens were capable of protecting against all five of the challenge strains. Broad-spectrum protection was achieved by using combinations of three strains of irradiated rickettsiae in a vaccination regimen of three injections at 5-day intervals
Gas-phase ion/ion reactions of peptides and proteins: acid/base, redox, and covalent chemistries.
Prentice, Boone M; McLuckey, Scott A
2013-02-01
Gas-phase ion/ion reactions are emerging as useful and flexible means for the manipulation and characterization of peptide and protein biopolymers. Acid/base-like chemical reactions (i.e., proton transfer reactions) and reduction/oxidation (redox) reactions (i.e., electron transfer reactions) represent relatively mature classes of gas-phase chemical reactions. Even so, especially in regards to redox chemistry, the widespread utility of these two types of chemistries is undergoing rapid growth and development. Additionally, a relatively new class of gas-phase ion/ion transformations is emerging which involves the selective formation of functional-group-specific covalent bonds. This feature details our current work and perspective on the developments and current capabilities of these three areas of ion/ion chemistry with an eye towards possible future directions of the field.
Blokker, P.; Pel, R.; Akoto, L.; Udo, A.; Brinkman, U.A.Th.; Vreuls, R.J.J.
2002-01-01
Thermally assisted hydrolysis and methylation¯gas chromatography (THM¯GC) is an important tool to analyse fatty acid in complex matrices. Since THM¯GC has major drawbacks such as isomerisation when applied to fatty acids in natural matrices, a direct thermal desorption (DTD) interface and an
Assessment of Purex solvent cleanup methods using a mixer-settler system
International Nuclear Information System (INIS)
Mailen, J.C.; Tallent, O.K.
1984-11-01
A test system consisting of three mixer-settlers in series has been used to determine the usefulness of several possible aqueous scrub solutions for cleanup of TBP solvent in fuel reprocessing plants. The simulated solvent that was treated was nominally 0.1 mM zirconium, 0.2 mM uranium, 0.4 mM dibutyl phosphate, and 0.3 mM HNO 3 . Five aqueous scrub solutions - sodium carbonate/tartrate, hydroxylamine/tartaric acid, hydroxylamine/citric acid, hydrazine/oxalic acid, and LiOH/sucrose - were evaluated. The order of effectiveness of these solutions for removal of contaminants was: sodium carbonate/tartrate, hydrazine/oxalic acid, LiOH/sucrose, and the two hydroxylamine solutions. Interfacial crud, which was related to the presence of zirconium and DBP, was observed in all cases except the LiOH/sucrose solution. The recommended system would use sodium carbonate/tartrate. If sodium usage must be minimized, a hydroxylamine-containing scrub followed by a sodium carbonate/tartrate scrub is recommended. 13 references, 11 figures, 21 tables
Energy Technology Data Exchange (ETDEWEB)
Nexant, Inc., San Francisco, California
2011-05-01
The first section (Task 1) of this report by Nexant includes a survey and screening of various acid gas removal processes in order to evaluate their capability to meet the specific design requirements for thermochemical ethanol synthesis in NREL's thermochemical ethanol design report (Phillips et al. 2007, NREL/TP-510-41168). MDEA and selexol were short-listed as the most promising acid-gas removal agents based on work described in Task 1. The second report section (Task 2) describes a detailed design of an MDEA (methyl diethanol amine) based acid gas removal system for removing CO2 and H2S from biomass-derived syngas. Only MDEA was chosen for detailed study because of the available resources.
Korn, M; Gfrörer, W; Herz, R; Wodarz, I; Wodarz, R
1992-01-01
Ethylbenzene is an important industrial solvent and a key substance in styrene production. Ethylbenzene metabolism leads to the formation of mandelic acid, which occurs in two enantiomeric forms, and phenylglyoxylic acid. To decide which enantiomer is preferably formed, 70 urine samples of exposed workers were taken at the end of shifts and--after 3-pentyl ester derivatisation--gas chromatographically analysed. The R/S ratio of mandelic acid enantiomers in urine amounts to 19:1, which means that R-mandelic acid is a major metabolite and S-mandelic acid is one of the minor urinary metabolites of ethylbenzene in man. The R/S ratio is independent of ambient air concentration of ethylbenzene within the investigated range. Compared to an ethylbenzene monoexposure the height of total mandelic acid excretion is decreased in the case of coexposure to other aromatic solvents.
Energy Technology Data Exchange (ETDEWEB)
Varanusupakul, Pakorn [Chromatography and Separation Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok 10330 (Thailand)], E-mail: pakorn.v@chula.ac.th; Vora-adisak, Narongchai; Pulpoka, Bancha [Chromatography and Separation Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok 10330 (Thailand)
2007-08-15
An alternative method for gas chromatographic determination of haloacetic acids (HAAs) in water using direct derivatization followed by hollow fiber membrane liquid-phase microextraction (HF-LPME) has been developed. The method has improved the sample preparation step according to the conventional US EPA Method 552.2 by combining the derivatization and the extraction into one step prior to determination by gas chromatography electron captured detector (GC-ECD). The HAAs were derivatized with acidic methanol into their methyl esters and simultaneously extracted with supported liquid hollow fiber membrane in headspace mode. The derivatization was attempted directly in water sample without sample evaporation. The HF-LPME was performed using 1-octanol as the extracting solvent at 55 deg. C for 60 min with 20% Na{sub 2}SO{sub 4}. The linear calibration curves were observed for the concentrations ranging from 1 to 300 {mu}g L{sup -1} with the correlation coefficients (R{sup 2}) being greater than 0.99. The method detection limits of most analytes were below 1 {mu}g L{sup -1} except DCAA and MCAA that were 2 and 18 {mu}g L{sup -1}, respectively. The recoveries from spiked concentration ranged from 97 to 109% with %R.S.D. less than 12%. The method was applied for determination of HAAs in drinking water and tap water samples. The method offers an easy one step high sample throughput sample preparation for gas chromatographic determination of haloacetic acids as well as other contaminants in water.
International Nuclear Information System (INIS)
Varanusupakul, Pakorn; Vora-adisak, Narongchai; Pulpoka, Bancha
2007-01-01
An alternative method for gas chromatographic determination of haloacetic acids (HAAs) in water using direct derivatization followed by hollow fiber membrane liquid-phase microextraction (HF-LPME) has been developed. The method has improved the sample preparation step according to the conventional US EPA Method 552.2 by combining the derivatization and the extraction into one step prior to determination by gas chromatography electron captured detector (GC-ECD). The HAAs were derivatized with acidic methanol into their methyl esters and simultaneously extracted with supported liquid hollow fiber membrane in headspace mode. The derivatization was attempted directly in water sample without sample evaporation. The HF-LPME was performed using 1-octanol as the extracting solvent at 55 deg. C for 60 min with 20% Na 2 SO 4 . The linear calibration curves were observed for the concentrations ranging from 1 to 300 μg L -1 with the correlation coefficients (R 2 ) being greater than 0.99. The method detection limits of most analytes were below 1 μg L -1 except DCAA and MCAA that were 2 and 18 μg L -1 , respectively. The recoveries from spiked concentration ranged from 97 to 109% with %R.S.D. less than 12%. The method was applied for determination of HAAs in drinking water and tap water samples. The method offers an easy one step high sample throughput sample preparation for gas chromatographic determination of haloacetic acids as well as other contaminants in water
Akoto, L.; Vreuls, R.J.J.; Irth, H.; Pel, R.; Stellaard, F.
2008-01-01
Gas chromatography (GC) has in recent times become an important tool for the fatty acid profiling of human blood and plasma. An at-line procedure used in the fatty acid profiling of whole/intact aquatic micro-organisms without any sample preparation was adapted for this work. A direct thermal
Akoto, L.; Vreuls, J.J.; Irth, H.; Pel, R.; Stellaard, F.
2008-01-01
Gas chromatography (GC) has in recent times become an important tool for the fatty acid profiling of human blood and plasma. An at-line procedure used in the fatty acid profiling of whole/intact aquatic micro-organisms without any sample preparation was adapted for this work. A direct thermal
Akoto, Lawrence; Vreuls, Rene J. J.; Irth, Hubertus; Pel, Roel; Stellaard, Frans
2008-01-01
Gas chromatography (GC) has in recent times become an important tool for the fatty acid profiling of human blood and plasma. An at-line procedure used in the fatty acid profiling of whole/intact aquatic micro-organisms without any sample preparation was adapted for this work. A direct thermal
DEFF Research Database (Denmark)
Vrachnos, Ath.; Kontogeorgis, Georgios; Voutsas, EC
2006-01-01
and extended in this study to the absorption of carbon dioxide into aqueous monoethanolamine (MEA) solutions and aqueous MDEA-MEA blends. The results of the model are compared with experimental data taken from the literature. Very satisfactory predictions of acidic gas vapor-liquid equilibrium over MDEA, MEA...
Incorporating full-scale experience into advanced limestone wet FGD designs
International Nuclear Information System (INIS)
Rader, P.C.; Bakke, E.
1992-01-01
Utilities choosing flue gas desulfurization as a strategy for compliance with Phase I of the 1990 Clean Air Act Amendments will largely turn to limestone wet scrubbing as the most cost-effective, least-risk option. State-of-the-art single absorber wet scrubbing systems can be designed to achieve: SO 2 removal efficiencies in excess of 95 %, system availabilities in excess of 98%, and byproducts which can be marketed or land filled. As a result of varying fuel characteristics, site considerations, and owner preferences, FGD plants for large central power stations are typically custom-designed. To avoid the risks associated with new, first-of-a-kind technologies, utilities have preferred to purchase FGD systems from suppliers with proven utility experience and reference plants as close as possible to the design envisioned. As the market for FGD systems is regulatory driven, the demand has shifted geographically in response to national environmental policies. Although limestone wet scrubbing has emerged as the overwhelming choice for SO 2 emission control in coal-fired power stations, the technology has evolved and been adapted to suit local and regional technical and economic situations. Global suppliers are able to benefit from experience and technological advances in the world market. With market units in the U.S., Denmark, Italy, Sweden, and Germany active in the design and supply of wet FGD plants, ABB has a unique ability to incorporate knowledge and experience gained throughout the industrialized world to acid rain retrofit projects in the U.S. This paper describes the design of advanced limestone wet scrubbing systems for application to acid rain retrofits. Specifically, the evolution of advanced design concepts from a global experience base is discussed
Chen, Hongliu; Ning, Zong; Qiu, Ying; Liao, Yuanli; Chang, Haihua; Ai, Yuanyuan; Wei, Yinghua; Deng, Yiming; Shen, Ying
2017-08-01
This study aimed to investigate whether von Willebrand factor (vWF) and high mobility group box 1 (HMGB1) are associated with the severity and clinical outcome of scrub typhus and to seek novel biomarkers for surveillance and prediction of the prognosis of this infection. Serum concentrations of vWF and HMGB1 were measured twice by ELISA for scrub typhus patients (n=103), once prior to doxycycline therapy and then on day 7 of doxycycline therapy; concentrations were measured once for healthy controls (n=32). Among the total 103 patients enrolled, 38 had disease complicated by multiple organ dysfunction syndrome (MODS). Serum concentrations of vWF and HMGB1 were significantly higher in all the patients than in the healthy controls, both prior to doxycycline treatment and on day 7 of doxycycline treatment (pscrub typhus (area under the curve (AUC)=0.864, p=0.001, and AUC=0.862, p=0.001, respectively). Elevated levels of vWF and HMGB1 are associated with the severity and clinical outcome of scrub typhus. These represent possible new biomarkers for use in the assessment and prognostic prediction of this infection. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Leptotrombidium chiangraiensis Tanskul and Linthicum and Leptotrombidium imphalum Vercammen-Grandjean are important vectors of scrub typhus in ricefield habitats in northern Thailand. The developmental biology of all stages of the life cycle of two generations of mites infected with Orientia tsutsug...
Larsson, L
1983-08-01
Mycobacterium avium-intracellulare and M.gastri were analyzed with capillary gas chromatography after each strain had been subjected to acidic methanolysis or to alkaline saponification followed by methylation. Prominent peaks of myristic, palmitoleic, palmitic, oleic, stearic and tuberculostearic acids were found in the chromatograms of both species, whereas 2-octadecanol and 2-eicosanol were detected only in M. avium-intracellulare. In initial runs, both of the derivatization principles yielded virtually identical chromatograms for a given strain. After repeated injections of extracts from alkaline saponification, however, the alcohol peaks showed pronounced tailing and finally almost disappeared from the chromatograms. This disadvantage, which was not observed when only acid methanolysis was used, could be overcome with trifluoroacetylation. Restored peak shape of the underivatized alcohols could be achieved by washing the cross-linked stationary phase in the capillary tubing with organic solvents. The study demonstrated the importance of conditions which enable separation of 2-octadecanol and 2-eicosanol when gas chromatography is used for species identification of mycobacteria.
International Nuclear Information System (INIS)
Hancevic, Pedro Ignacio
2017-01-01
The Acid Rain Program (ARP) was implemented in 1995. Since then, coal-fired boilers have had to choose among three main compliance alternatives: purchase pollution permits; switch to an alternative lower-sulfur coal; or adopt a scrubber. This decision problem is driven by the evolution of several economic variables and is revised when significant changes (to prices, quality of inputs, output level, technology, transport costs, regulations, among others) occur. Using a structural dynamic discrete choice model, I recover cost parameters and use them to evaluate two different counterfactual policies. The results confirm there is a trade-off between fuel switching and scrubbing costs (with the latter having a higher investment cost and a lower variable cost), and also the existence of regional heterogeneity. Finally, the ARP implied cost savings of approximately $4.7 billions if compared to a uniform emission rate standard and $14.8 billions if compared to compulsory scrubbing for the 1995–2005 period. - Highlights: • With the cap-and-trade system of the ARP boilers had three main compliance options. • Purchase allowances; retrofit the boiler to burn low-sulfur coal; adopt scrubbers. • We develop and estimate a rigorous structural dynamic discrete choice model. • Trade-off between fuel switching and scrubbing (capital versus operating costs). • Cost savings from the ARP were substantial if compared to previous regulations.